Sample records for practice vii stereoscopic

  1. Web GIS in practice VII: stereoscopic 3-D solutions for online maps and virtual globes

    PubMed Central

    Boulos, Maged N Kamel; Robinson, Larry R

    2009-01-01

    Because our pupils are about 6.5 cm apart, each eye views a scene from a different angle and sends a unique image to the visual cortex, which then merges the images from both eyes into a single picture. The slight difference between the right and left images allows the brain to properly perceive the 'third dimension' or depth in a scene (stereopsis). However, when a person views a conventional 2-D (two-dimensional) image representation of a 3-D (three-dimensional) scene on a conventional computer screen, each eye receives essentially the same information. Depth in such cases can only be approximately inferred from visual clues in the image, such as perspective, as only one image is offered to both eyes. The goal of stereoscopic 3-D displays is to project a slightly different image into each eye to achieve a much truer and realistic perception of depth, of different scene planes, and of object relief. This paper presents a brief review of a number of stereoscopic 3-D hardware and software solutions for creating and displaying online maps and virtual globes (such as Google Earth) in "true 3D", with costs ranging from almost free to multi-thousand pounds sterling. A practical account is also given of the experience of the USGS BRD UMESC (United States Geological Survey's Biological Resources Division, Upper Midwest Environmental Sciences Center) in setting up a low-cost, full-colour stereoscopic 3-D system. PMID:19849837

  2. Web GIS in practice VII: stereoscopic 3-D solutions for online maps and virtual globes.

    PubMed

    Boulos, Maged N Kamel; Robinson, Larry R

    2009-10-22

    Because our pupils are about 6.5 cm apart, each eye views a scene from a different angle and sends a unique image to the visual cortex, which then merges the images from both eyes into a single picture. The slight difference between the right and left images allows the brain to properly perceive the 'third dimension' or depth in a scene (stereopsis). However, when a person views a conventional 2-D (two-dimensional) image representation of a 3-D (three-dimensional) scene on a conventional computer screen, each eye receives essentially the same information. Depth in such cases can only be approximately inferred from visual clues in the image, such as perspective, as only one image is offered to both eyes. The goal of stereoscopic 3-D displays is to project a slightly different image into each eye to achieve a much truer and realistic perception of depth, of different scene planes, and of object relief. This paper presents a brief review of a number of stereoscopic 3-D hardware and software solutions for creating and displaying online maps and virtual globes (such as Google Earth) in "true 3D", with costs ranging from almost free to multi-thousand pounds sterling. A practical account is also given of the experience of the USGS BRD UMESC (United States Geological Survey's Biological Resources Division, Upper Midwest Environmental Sciences Center) in setting up a low-cost, full-colour stereoscopic 3-D system.

  3. Web GIS in practice VII: stereoscopic 3-D solutions for online maps and virtual globes

    USGS Publications Warehouse

    Boulos, Maged N.K.; Robinson, Larry R.

    2009-01-01

    Because our pupils are about 6.5 cm apart, each eye views a scene from a different angle and sends a unique image to the visual cortex, which then merges the images from both eyes into a single picture. The slight difference between the right and left images allows the brain to properly perceive the 'third dimension' or depth in a scene (stereopsis). However, when a person views a conventional 2-D (two-dimensional) image representation of a 3-D (three-dimensional) scene on a conventional computer screen, each eye receives essentially the same information. Depth in such cases can only be approximately inferred from visual clues in the image, such as perspective, as only one image is offered to both eyes. The goal of stereoscopic 3-D displays is to project a slightly different image into each eye to achieve a much truer and realistic perception of depth, of different scene planes, and of object relief. This paper presents a brief review of a number of stereoscopic 3-D hardware and software solutions for creating and displaying online maps and virtual globes (such as Google Earth) in "true 3D", with costs ranging from almost free to multi-thousand pounds sterling. A practical account is also given of the experience of the USGS BRD UMESC (United States Geological Survey's Biological Resources Division, Upper Midwest Environmental Sciences Center) in setting up a low-cost, full-colour stereoscopic 3-D system.

  4. Title VII funding and physician practice in rural or low-income areas.

    PubMed

    Krist, Alex H; Johnson, Robert E; Callahan, David; Woolf, Steven H; Marsland, David

    2005-01-01

    Whether Title VII funding enhances physician supply in underserved areas has not clearly been established. To determine the relation between Title VII funding in medical school, residency, or both, and the number of family physicians practicing in rural or low-income communities. A retrospective cross sectional analysis was carried out using the 2000 American Academy of Family Physicians physician database, Title VII funding records, and 1990 U.S. Census data. Included were 9,107 family physicians practicing in 9 nationally representative states in the year 2000. Physicians exposed to Title VII funding through medical school and residency were more likely to have their current practice in low-income communities (11.9% vs 9.9%, P< or =.02) and rural areas (24.5% vs 21.8%, P< or =.02). Physicians were more likely to practice in rural communities if they attended medical schools (24.2% vs 21.4%; P =.009) and residencies (24.0% vs 20.3%; P =.011) after the school or program had at least 5 years of Title VII funding vs before. Similar increases were not observed for practice in low-income communities. In a multivariate analysis, exposure to funding and attending an institution with more years of funding independently increased the odds of practicing in rural or low-income communities. Title VII funding is associated with an increase in the family physician workforce in rural and low-income communities. This effect is temporally related to initiation of funding and independently associated with effect in a multivariate analysis, suggesting a potential causal relationship. Whereas the absolute 2% increase in family physicians in these underserved communities may seem modest, it can represent a substantial increase in access to health care for community members.

  5. Human factors involved in perception and action in a natural stereoscopic world: an up-to-date review with guidelines for stereoscopic displays and stereoscopic virtual reality (VR)

    NASA Astrophysics Data System (ADS)

    Perez-Bayas, Luis

    2001-06-01

    In stereoscopic perception of a three-dimensional world, binocular disparity might be thought of as the most important cue to 3D depth perception. Nevertheless, in reality there are many other factors involved before the 'final' conscious and subconscious stereoscopic perception, such as luminance, contrast, orientation, color, motion, and figure-ground extraction (pop-out phenomenon). In addition, more complex perceptual factors exist, such as attention and its duration (an equivalent of 'brain zooming') in relation to physiological central vision, In opposition to attention to peripheral vision and the brain 'top-down' information in relation to psychological factors like memory of previous experiences and present emotions. The brain's internal mapping of a pure perceptual world might be different from the internal mapping of a visual-motor space, which represents an 'action-directed perceptual world.' In addition, psychological factors (emotions and fine adjustments) are much more involved in a stereoscopic world than in a flat 2D-world, as well as in a world using peripheral vision (like VR, using a curved perspective representation, and displays, as natural vision does) as opposed to presenting only central vision (bi-macular stereoscopic vision) as in the majority of typical stereoscopic displays. Here is presented the most recent and precise information available about the psycho-neuro- physiological factors involved in the perception of stereoscopic three-dimensional world, with an attempt to give practical, functional, and pertinent guidelines for building more 'natural' stereoscopic displays.

  6. Compression of stereoscopic video using MPEG-2

    NASA Astrophysics Data System (ADS)

    Puri, A.; Kollarits, Richard V.; Haskell, Barry G.

    1995-10-01

    Many current as well as emerging applications in areas of entertainment, remote operations, manufacturing industry and medicine can benefit from the depth perception offered by stereoscopic video systems which employ two views of a scene imaged under the constraints imposed by human visual system. Among the many challenges to be overcome for practical realization and widespread use of 3D/stereoscopic systems are good 3D displays and efficient techniques for digital compression of enormous amounts of data while maintaining compatibility with normal video decoding and display systems. After a brief introduction to the basics of 3D/stereo including issues of depth perception, stereoscopic 3D displays and terminology in stereoscopic imaging and display, we present an overview of tools in the MPEG-2 video standard that are relevant to our discussion on compression of stereoscopic video, which is the main topic of this paper. Next, we outilne the various approaches for compression of stereoscopic video and then focus on compatible stereoscopic video coding using MPEG-2 Temporal scalability concepts. Compatible coding employing two different types of prediction structures become potentially possible, disparity compensated prediction and combined disparity and motion compensated predictions. To further improve coding performance and display quality, preprocessing for reducing mismatch between the two views forming stereoscopic video is considered. Results of simulations performed on stereoscopic video of normal TV resolution are then reported comparing the performance of two prediction structures with the simulcast solution. It is found that combined disparity and motion compensated prediction offers the best performance. Results indicate that compression of both views of stereoscopic video of normal TV resolution appears feasible in a total of 6 to 8 Mbit/s. We then discuss regarding multi-viewpoint video, a generalization of stereoscopic video. Finally, we describe

  7. Compression of stereoscopic video using MPEG-2

    NASA Astrophysics Data System (ADS)

    Puri, Atul; Kollarits, Richard V.; Haskell, Barry G.

    1995-12-01

    Many current as well as emerging applications in areas of entertainment, remote operations, manufacturing industry and medicine can benefit from the depth perception offered by stereoscopic video systems which employ two views of a scene imaged under the constraints imposed by human visual system. Among the many challenges to be overcome for practical realization and widespread use of 3D/stereoscopic systems are good 3D displays and efficient techniques for digital compression of enormous amounts of data while maintaining compatibility with normal video decoding and display systems. After a brief introduction to the basics of 3D/stereo including issues of depth perception, stereoscopic 3D displays and terminology in stereoscopic imaging and display, we present an overview of tools in the MPEG-2 video standard that are relevant to our discussion on compression of stereoscopic video, which is the main topic of this paper. Next, we outline the various approaches for compression of stereoscopic video and then focus on compatible stereoscopic video coding using MPEG-2 Temporal scalability concepts. Compatible coding employing two different types of prediction structures become potentially possible, disparity compensated prediction and combined disparity and motion compensated predictions. To further improve coding performance and display quality, preprocessing for reducing mismatch between the two views forming stereoscopic video is considered. Results of simulations performed on stereoscopic video of normal TV resolution are then reported comparing the performance of two prediction structures with the simulcast solution. It is found that combined disparity and motion compensated prediction offers the best performance. Results indicate that compression of both views of stereoscopic video of normal TV resolution appears feasible in a total of 6 to 8 Mbit/s. We then discuss regarding multi-viewpoint video, a generalization of stereoscopic video. Finally, we describe

  8. Matte painting in stereoscopic synthetic imagery

    NASA Astrophysics Data System (ADS)

    Eisenmann, Jonathan; Parent, Rick

    2010-02-01

    While there have been numerous studies concerning human perception in stereoscopic environments, rules of thumb for cinematography in stereoscopy have not yet been well-established. To that aim, we present experiments and results of subject testing in a stereoscopic environment, similar to that of a theater (i.e. large flat screen without head-tracking). In particular we wish to empirically identify thresholds at which different types of backgrounds, referred to in the computer animation industry as matte paintings, can be used while still maintaining the illusion of seamless perspective and depth for a particular scene and camera shot. In monoscopic synthetic imagery, any type of matte painting that maintains proper perspective lines, depth cues, and coherent lighting and textures saves in production costs while still maintaining the illusion of an alternate cinematic reality. However, in stereoscopic synthetic imagery, a 2D matte painting that worked in monoscopy may fail to provide the intended illusion of depth because the viewer has added depth information provided by stereopsis. We intend to observe two stereoscopic perceptual thresholds in this study which will provide practical guidelines indicating when to use each of three types of matte paintings. We ran subject tests in two virtual testing environments, each with varying conditions. Data were collected showing how the choices of the users matched the correct response, and the resulting perceptual threshold patterns are discussed below.

  9. Evaluating methods for controlling depth perception in stereoscopic cinematography

    NASA Astrophysics Data System (ADS)

    Sun, Geng; Holliman, Nick

    2009-02-01

    Existing stereoscopic imaging algorithms can create static stereoscopic images with perceived depth control function to ensure a compelling 3D viewing experience without visual discomfort. However, current algorithms do not normally support standard Cinematic Storytelling techniques. These techniques, such as object movement, camera motion, and zooming, can result in dynamic scene depth change within and between a series of frames (shots) in stereoscopic cinematography. In this study, we empirically evaluate the following three types of stereoscopic imaging approaches that aim to address this problem. (1) Real-Eye Configuration: set camera separation equal to the nominal human eye interpupillary distance. The perceived depth on the display is identical to the scene depth without any distortion. (2) Mapping Algorithm: map the scene depth to a predefined range on the display to avoid excessive perceived depth. A new method that dynamically adjusts the depth mapping from scene space to display space is presented in addition to an existing fixed depth mapping method. (3) Depth of Field Simulation: apply Depth of Field (DOF) blur effect to stereoscopic images. Only objects that are inside the DOF are viewed in full sharpness. Objects that are far away from the focus plane are blurred. We performed a human-based trial using the ITU-R BT.500-11 Recommendation to compare the depth quality of stereoscopic video sequences generated by the above-mentioned imaging methods. Our results indicate that viewers' practical 3D viewing volumes are different for individual stereoscopic displays and viewers can cope with much larger perceived depth range in viewing stereoscopic cinematography in comparison to static stereoscopic images. Our new dynamic depth mapping method does have an advantage over the fixed depth mapping method in controlling stereo depth perception. The DOF blur effect does not provide the expected improvement for perceived depth quality control in 3D cinematography

  10. Stereoscopic 3D graphics generation

    NASA Astrophysics Data System (ADS)

    Li, Zhi; Liu, Jianping; Zan, Y.

    1997-05-01

    Stereoscopic display technology is one of the key techniques of areas such as simulation, multimedia, entertainment, virtual reality, and so on. Moreover, stereoscopic 3D graphics generation is an important part of stereoscopic 3D display system. In this paper, at first, we describe the principle of stereoscopic display and summarize some methods to generate stereoscopic 3D graphics. Secondly, to overcome the problems which came from the methods of user defined models (such as inconvenience, long modifying period and so on), we put forward the vector graphics files defined method. Thus we can design more directly; modify the model simply and easily; generate more conveniently; furthermore, we can make full use of graphics accelerator card and so on. Finally, we discuss the problem of how to speed up the generation.

  11. Using mental rotation to evaluate the benefits of stereoscopic displays

    NASA Astrophysics Data System (ADS)

    Aitsiselmi, Y.; Holliman, N. S.

    2009-02-01

    Context: The idea behind stereoscopic displays is to create the illusion of depth and this concept could have many practical applications. A common spatial ability test involves mental rotation. Therefore a mental rotation task should be easier if being undertaken on a stereoscopic screen. Aim: The aim of this project is to evaluate stereoscopic displays (3D screen) and to assess whether they are better for performing a certain task than over a 2D display. A secondary aim was to perform a similar study but replicating the conditions of using a stereoscopic mobile phone screen. Method: We devised a spatial ability test involving a mental rotation task that participants were asked to complete on either a 3D or 2D screen. We also design a similar task to simulate the experience on a stereoscopic cell phone. The participants' error rate and response times were recorded. Using statistical analysis, we then compared the error rate and response times of the groups to see if there were any significant differences. Results: We found that the participants got better scores if they were doing the task on a stereoscopic screen as opposed to a 2D screen. However there was no statistically significant difference in the time it took them to complete the task. We also found similar results for 3D cell phone display condition. Conclusions: The results show that the extra depth information given by a stereoscopic display makes it easier to mentally rotate a shape as depth cues are readily available. These results could have many useful implications to certain industries.

  12. Stereoscopic game design and evaluation

    NASA Astrophysics Data System (ADS)

    Rivett, Joe; Holliman, Nicolas

    2013-03-01

    We report on a new game design where the goal is to make the stereoscopic depth cue sufficiently critical to success that game play should become impossible without using a stereoscopic 3D (S3D) display and, at the same time, we investigate whether S3D game play is affected by screen size. Before we detail our new game design we review previously unreported results from our stereoscopic game research over the last ten years at the Durham Visualisation Laboratory. This demonstrates that game players can achieve significantly higher scores using S3D displays when depth judgements are an integral part of the game. Method: We design a game where almost all depth cues, apart from the binocular cue, are removed. The aim of the game is to steer a spaceship through a series of oncoming hoops where the viewpoint of the game player is from above, with the hoops moving right to left across the screen towards the spaceship, to play the game it is essential to make decisive depth judgments to steer the spaceship through each oncoming hoop. To confound these judgements we design altered depth cues, for example perspective is reduced as a cue by varying the hoop's depth, radius and cross-sectional size. Results: Players were screened for stereoscopic vision, given a short practice session, and then played the game in both 2D and S3D modes on a seventeen inch desktop display, on average participants achieved a more than three times higher score in S3D than they achieved in 2D. The same experiment was repeated using a four metre S3D projection screen and similar results were found. Conclusions: Our conclusion is that games that use the binocular depth cue in decisive game judgements can benefit significantly from using an S3D display. Based on both our current and previous results we additionally conclude that display size, from cell-phone, to desktop, to projection display does not adversely affect player performance.

  13. [Dendrobium officinale stereoscopic cultivation method].

    PubMed

    Si, Jin-Ping; Dong, Hong-Xiu; Liao, Xin-Yan; Zhu, Yu-Qiu; Li, Hui

    2014-12-01

    The study is aimed to make the most of available space of Dendrobium officinale cultivation facility, reveal the yield and functional components variation of stereoscopic cultivated D. officinale, and improve quality, yield and efficiency. The agronomic traits and yield variation of stereoscopic cultivated D. officinale were studied by operating field experiment. The content of polysaccharide and extractum were determined by using phenol-sulfuric acid method and 2010 edition of "Chinese Pharmacopoeia" Appendix X A. The results showed that the land utilization of stereoscopic cultivated D. officinale increased 2.74 times, the stems, leaves and their total fresh or dry weight in unit area of stereoscopic cultivated D. officinale were all heavier than those of the ground cultivated ones. There was no significant difference in polysaccharide content between stereoscopic cultivation and ground cultivation. But the extractum content and total content of polysaccharide and extractum were significantly higher than those of the ground cultivated ones. In additional, the polysaccharide content and total content of polysaccharide and extractum from the top two levels of stereoscopic culture matrix were significantly higher than that of the ones from the other levels and ground cultivation. Steroscopic cultivation can effectively improves the utilization of space and yield, while the total content of polysaccharides and extractum were significantly higher than that of the ground cultivated ones. The significant difference in Dendrobium polysaccharides among the plants from different height of stereo- scopic culture matrix may be associated with light factor.

  14. Stereoscopic augmented reality for laparoscopic surgery.

    PubMed

    Kang, Xin; Azizian, Mahdi; Wilson, Emmanuel; Wu, Kyle; Martin, Aaron D; Kane, Timothy D; Peters, Craig A; Cleary, Kevin; Shekhar, Raj

    2014-07-01

    Conventional laparoscopes provide a flat representation of the three-dimensional (3D) operating field and are incapable of visualizing internal structures located beneath visible organ surfaces. Computed tomography (CT) and magnetic resonance (MR) images are difficult to fuse in real time with laparoscopic views due to the deformable nature of soft-tissue organs. Utilizing emerging camera technology, we have developed a real-time stereoscopic augmented-reality (AR) system for laparoscopic surgery by merging live laparoscopic ultrasound (LUS) with stereoscopic video. The system creates two new visual cues: (1) perception of true depth with improved understanding of 3D spatial relationships among anatomical structures, and (2) visualization of critical internal structures along with a more comprehensive visualization of the operating field. The stereoscopic AR system has been designed for near-term clinical translation with seamless integration into the existing surgical workflow. It is composed of a stereoscopic vision system, a LUS system, and an optical tracker. Specialized software processes streams of imaging data from the tracked devices and registers those in real time. The resulting two ultrasound-augmented video streams (one for the left and one for the right eye) give a live stereoscopic AR view of the operating field. The team conducted a series of stereoscopic AR interrogations of the liver, gallbladder, biliary tree, and kidneys in two swine. The preclinical studies demonstrated the feasibility of the stereoscopic AR system during in vivo procedures. Major internal structures could be easily identified. The system exhibited unobservable latency with acceptable image-to-video registration accuracy. We presented the first in vivo use of a complete system with stereoscopic AR visualization capability. This new capability introduces new visual cues and enhances visualization of the surgical anatomy. The system shows promise to improve the precision and

  15. Redundancy of stereoscopic images: Experimental evaluation

    NASA Astrophysics Data System (ADS)

    Yaroslavsky, L. P.; Campos, J.; Espínola, M.; Ideses, I.

    2005-12-01

    With the recent advancement in visualization devices over the last years, we are seeing a growing market for stereoscopic content. In order to convey 3D content by means of stereoscopic displays, one needs to transmit and display at least 2 points of view of the video content. This has profound implications on the resources required to transmit the content, as well as demands on the complexity of the visualization system. It is known that stereoscopic images are redundant which may prove useful for compression and may have positive effect on the construction of the visualization device. In this paper we describe an experimental evaluation of data redundancy in color stereoscopic images. In the experiments with computer generated and real life test stereo images, several observers visually tested the stereopsis threshold and accuracy of parallax measurement in anaglyphs and stereograms as functions of the blur degree of one of two stereo images. In addition, we tested the color saturation threshold in one of two stereo images for which full color 3D perception with no visible color degradations was maintained. The experiments support a theoretical estimate that one has to add, to data required to reproduce one of two stereoscopic images, only several percents of that amount of data in order to achieve stereoscopic perception.

  16. Analysis of physiological impact while reading stereoscopic radiographs

    NASA Astrophysics Data System (ADS)

    Unno, Yasuko Y.; Tajima, Takashi; Kuwabara, Takao; Hasegawa, Akira; Natsui, Nobutaka; Ishikawa, Kazuo; Hatada, Toyohiko

    2011-03-01

    A stereoscopic viewing technology is expected to improve diagnostic performance in terms of reading efficiency by adding one more dimension to the conventional 2D images. Although a stereoscopic technology has been applied to many different field including TV, movies and medical applications, physiological fatigue through reading stereoscopic radiographs has been concerned although no established physiological fatigue data have been provided. In this study, we measured the α-amylase concentration in saliva, heart rates and normalized tissue hemoglobin index (nTHI) in blood of frontal area to estimate physiological fatigue through reading both stereoscopic radiographs and the conventional 2D radiographs. In addition, subjective assessments were also performed. As a result, the pupil contraction occurred just after the reading of the stereoscopic images, but the subjective assessments regarding visual fatigue were nearly identical for the reading the conventional 2D and stereoscopic radiographs. The α-amylase concentration and the nTHI continued to decline while examinees read both 2D and stereoscopic images, which reflected the result of subjective assessment that almost half of the examinees reported to feel sleepy after reading. The subjective assessments regarding brain fatigue showed that there were little differences between 2D and stereoscopic reading. In summary, this study shows that the physiological fatigue caused by stereoscopic reading is equivalent to the conventional 2D reading including ocular fatigue and burden imposed on brain.

  17. Polarizing aperture stereoscopic cinema camera

    NASA Astrophysics Data System (ADS)

    Lipton, Lenny

    2012-03-01

    The art of stereoscopic cinematography has been held back because of the lack of a convenient way to reduce the stereo camera lenses' interaxial to less than the distance between the eyes. This article describes a unified stereoscopic camera and lens design that allows for varying the interaxial separation to small values using a unique electro-optical polarizing aperture design for imaging left and right perspective views onto a large single digital sensor (the size of the standard 35mm frame) with the means to select left and right image information. Even with the added stereoscopic capability the appearance of existing camera bodies will be unaltered.

  18. Polarizing aperture stereoscopic cinema camera

    NASA Astrophysics Data System (ADS)

    Lipton, Lenny

    2012-07-01

    The art of stereoscopic cinematography has been held back because of the lack of a convenient way to reduce the stereo camera lenses' interaxial to less than the distance between the eyes. This article describes a unified stereoscopic camera and lens design that allows for varying the interaxial separation to small values using a unique electro-optical polarizing aperture design for imaging left and right perspective views onto a large single digital sensor, the size of the standard 35 mm frame, with the means to select left and right image information. Even with the added stereoscopic capability, the appearance of existing camera bodies will be unaltered.

  19. Original and creative stereoscopic film making

    NASA Astrophysics Data System (ADS)

    Criado, Enrique

    2008-02-01

    The stereoscopic cinema has become, once again, a hot topic in the film production. For filmmakers to be successful in this field, a technical background in the principles of binocular perception and how our brain interprets the incoming data from our eyes, are fundamental. It is also paramount for a stereoscopic production to adhere certain rules for comfort and safety. There is an immense variety of options in the art of standard "flat" photography, and the possibilities only can be multiply with the stereo. The stereoscopic imaging has its own unique areas for subjective, original and creative control that allow an incredible range of possible combinations by working inside the standards, and in some cases on the boundaries of the basic stereo rules. The stereoscopic imaging can be approached in a "flat" manner, like channeling sound through an audio equalizer with all the bands at the same level. It can provide a realistic perception, which in many cases can be sufficient, thanks to the rock-solid viewing inherent to the stereoscopic image, but there are many more possibilities. This document describes some of the basic operating parameters and concepts for stereoscopic imaging, but it also offers ideas for a creative process based on the variation and combination of these basic parameters, which can lead into a truly innovative and original viewing experience.

  20. Brief history of electronic stereoscopic displays

    NASA Astrophysics Data System (ADS)

    Lipton, Lenny

    2012-02-01

    A brief history of recent developments in electronic stereoscopic displays is given concentrating on products that have succeeded in the market place and hence have had a significant influence on future implementations. The concentration is on plano-stereoscopic (two-view) technology because it is now the dominant display modality in the marketplace. Stereoscopic displays were created for the motion picture industry a century ago, and this technology influenced the development of products for science and industry, which in turn influenced product development for entertainment.

  1. Binocular coordination in response to stereoscopic stimuli

    NASA Astrophysics Data System (ADS)

    Liversedge, Simon P.; Holliman, Nicolas S.; Blythe, Hazel I.

    2009-02-01

    Humans actively explore their visual environment by moving their eyes. Precise coordination of the eyes during visual scanning underlies the experience of a unified perceptual representation and is important for the perception of depth. We report data from three psychological experiments investigating human binocular coordination during visual processing of stereoscopic stimuli.In the first experiment participants were required to read sentences that contained a stereoscopically presented target word. Half of the word was presented exclusively to one eye and half exclusively to the other eye. Eye movements were recorded and showed that saccadic targeting was uninfluenced by the stereoscopic presentation, strongly suggesting that complementary retinal stimuli are perceived as a single, unified input prior to saccade initiation. In a second eye movement experiment we presented words stereoscopically to measure Panum's Fusional Area for linguistic stimuli. In the final experiment we compared binocular coordination during saccades between simple dot stimuli under 2D, stereoscopic 3D and real 3D viewing conditions. Results showed that depth appropriate vergence movements were made during saccades and fixations to real 3D stimuli, but only during fixations on stereoscopic 3D stimuli. 2D stimuli did not induce depth vergence movements. Together, these experiments indicate that stereoscopic visual stimuli are fused when they fall within Panum's Fusional Area, and that saccade metrics are computed on the basis of a unified percept. Also, there is sensitivity to non-foveal retinal disparity in real 3D stimuli, but not in stereoscopic 3D stimuli, and the system responsible for binocular coordination responds to this during saccades as well as fixations.

  2. Stereoscopic applications for design visualization

    NASA Astrophysics Data System (ADS)

    Gilson, Kevin J.

    2007-02-01

    Advances in display technology and 3D design visualization applications have made real-time stereoscopic visualization of architectural and engineering projects a reality. Parsons Brinkerhoff (PB) is a transportation consulting firm that has used digital visualization tools from their inception and has helped pioneer the application of those tools to large scale infrastructure projects. PB is one of the first Architecture/Engineering/Construction (AEC) firms to implement a CAVE- an immersive presentation environment that includes stereoscopic rear-projection capability. The firm also employs a portable stereoscopic front-projection system, and shutter-glass systems for smaller groups. PB is using commercial real-time 3D applications in combination with traditional 3D modeling programs to visualize and present large AEC projects to planners, clients and decision makers in stereo. These presentations create more immersive and spatially realistic presentations of the proposed designs. This paper will present the basic display tools and applications, and the 3D modeling techniques PB is using to produce interactive stereoscopic content. The paper will discuss several architectural and engineering design visualizations we have produced.

  3. Jig For Stereoscopic Photography

    NASA Technical Reports Server (NTRS)

    Nielsen, David J.

    1990-01-01

    Separations between views adjusted precisely for best results. Simple jig adjusted to set precisely, distance between right and left positions of camera used to make stereoscopic photographs. Camera slides in slot between extreme positions, where it takes stereoscopic pictures. Distance between extreme positions set reproducibly with micrometer. In view of trend toward very-large-scale integration of electronic circuits, training method and jig used to make training photographs useful to many companies to reduce cost of training manufacturing personnel.

  4. Two Eyes, 3D: Stereoscopic Design Principles

    NASA Astrophysics Data System (ADS)

    Price, Aaron; Subbarao, M.; Wyatt, R.

    2013-01-01

    Two Eyes, 3D is a NSF-funded research project about how people perceive highly spatial objects when shown with 2D or stereoscopic ("3D") representations. As part of the project, we produced a short film about SN 2011fe. The high definition film has been rendered in both 2D and stereoscopic formats. It was developed according to a set of stereoscopic design principles we derived from the literature and past experience producing and studying stereoscopic films. Study participants take a pre- and post-test that involves a spatial cognition assessment and scientific knowledge questions about Type-1a supernovae. For the evaluation, participants use iPads in order to record spatial manipulation of the device and look for elements of embodied cognition. We will present early results and also describe the stereoscopic design principles and the rationale behind them. All of our content and software is available under open source licenses. More information is at www.twoeyes3d.org.

  5. A stereoscopic lens for digital cinema cameras

    NASA Astrophysics Data System (ADS)

    Lipton, Lenny; Rupkalvis, John

    2015-03-01

    Live-action stereoscopic feature films are, for the most part, produced using a costly post-production process to convert planar cinematography into stereo-pair images and are only occasionally shot stereoscopically using bulky dual-cameras that are adaptations of the Ramsdell rig. The stereoscopic lens design described here might very well encourage more live-action image capture because it uses standard digital cinema cameras and workflow to save time and money.

  6. DWT-based stereoscopic image watermarking

    NASA Astrophysics Data System (ADS)

    Chammem, A.; Mitrea, M.; Pr"teux, F.

    2011-03-01

    Watermarking already imposed itself as an effective and reliable solution for conventional multimedia content protection (image/video/audio/3D). By persistently (robustly) and imperceptibly (transparently) inserting some extra data into the original content, the illegitimate use of data can be detected without imposing any annoying constraint to a legal user. The present paper deals with stereoscopic image protection by means of watermarking techniques. That is, we first investigate the peculiarities of the visual stereoscopic content from the transparency and robustness point of view. Then, we advance a new watermarking scheme designed so as to reach the trade-off between transparency and robustness while ensuring a prescribed quantity of inserted information. Finally, this method is evaluated on two stereoscopic image corpora (natural image and medical data).

  7. 21 CFR 886.1880 - Fusion and stereoscopic target.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fusion and stereoscopic target. 886.1880 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1880 Fusion and stereoscopic target. (a) Identification. A fusion and stereoscopic target is a device intended for use as a viewing object...

  8. 21 CFR 886.1880 - Fusion and stereoscopic target.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fusion and stereoscopic target. 886.1880 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1880 Fusion and stereoscopic target. (a) Identification. A fusion and stereoscopic target is a device intended for use as a viewing object...

  9. Measuring stereoscopic image quality experience with interpretation based quality methodology

    NASA Astrophysics Data System (ADS)

    Häkkinen, Jukka; Kawai, Takashi; Takatalo, Jari; Leisti, Tuomas; Radun, Jenni; Hirsaho, Anni; Nyman, Göte

    2008-01-01

    Stereoscopic technologies have developed significantly in recent years. These advances require also more understanding of the experiental dimensions of stereoscopic contents. In this article we describe experiments in which we explore the experiences that viewers have when they view stereoscopic contents. We used eight different contents that were shown to the participants in a paired comparison experiment where the task of the participants was to compare the same content in stereoscopic and non-stereoscopic form. The participants indicated their preference but were also interviewed about the arguments they used when making the decision. By conducting a qualitative analysis of the interview texts we categorized the significant experiental factors related to viewing stereoscopic material. Our results indicate that reality-likeness as well as artificiality were often used as arguments in comparing the stereoscopic materials. Also, there were more emotional terms in the descriptions of the stereoscopic films, which might indicate that the stereoscopic projection technique enhances the emotions conveyed by the film material. Finally, the participants indicated that the three-dimensional material required longer presentation time, as there were more interesting details to see.

  10. Stereoscopic Configurations To Minimize Distortions

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B.

    1991-01-01

    Proposed television system provides two stereoscopic displays. Two-camera, two-monitor system used in various camera configurations and with stereoscopic images on monitors magnified to various degrees. Designed to satisfy observer's need to perceive spatial relationships accurately throughout workspace or to perceive them at high resolution in small region of workspace. Potential applications include industrial, medical, and entertainment imaging and monitoring and control of telemanipulators, telerobots, and remotely piloted vehicles.

  11. Ghosting in anaglyphic stereoscopic images

    NASA Astrophysics Data System (ADS)

    Woods, Andrew J.; Rourke, Tegan

    2004-05-01

    Anaglyphic 3D images are an easy way of displaying stereoscopic 3D images on a wide range of display types, e.g. CRT, LCD, print, etc. While the anaglyphic 3D image method is cheap and accessible, its use requires a compromise in stereoscopic image quality. A common problem with anaglyphic 3D images is ghosting. Ghosting (or crosstalk) is the leaking of an image to one eye, when it is intended exclusively for the other eye. Ghosting degrades the ability of the observer to fuse the stereoscopic image and hence the quality of the 3D image is reduced. Ghosting is present in various levels with most stereoscopic displays, however it is often particularly evident with anaglyphic 3D images. This paper describes a project whose aim was to characterize the presence of ghosting in anaglyphic 3D images due to spectral issues. The spectral response curves of several different display types and several different brands of anaglyph glasses were measured using a spectroradiometer or spectrophotometer. A mathematical model was then developed to predict the amount of crosstalk in anaglyphic 3D images when different combinations of displays and glasses are used, and therefore predict the best type of anaglyph glasses for use with a particular display type.

  12. Contrast sensitivity function in stereoscopic viewing of Gabor patches on a medical polarized three-dimensional stereoscopic display

    NASA Astrophysics Data System (ADS)

    Rousson, Johanna; Haar, Jérémy; Santal, Sarah; Kumcu, Asli; Platiša, Ljiljana; Piepers, Bastian; Kimpe, Tom; Philips, Wilfried

    2016-03-01

    While three-dimensional (3-D) imaging systems are entering hospitals, no study to date has explored the luminance calibration needs of 3-D stereoscopic diagnostic displays and if they differ from two-dimensional (2-D) displays. Since medical display calibration incorporates the human contrast sensitivity function (CSF), we first assessed the 2-D CSF for benchmarking and then examined the impact of two image parameters on the 3-D stereoscopic CSF: (1) five depth plane (DP) positions (between DP: -171 and DP: 2853 mm), and (2) three 3-D inclinations (0 deg, 45 deg, and 60 deg around the horizontal axis of a DP). Stimuli were stereoscopic images of a vertically oriented 2-D Gabor patch at one of seven frequencies ranging from 0.4 to 10 cycles/deg. CSFs were measured for seven to nine human observers with a staircase procedure. The results indicate that the 2-D CSF model remains valid for a 3-D stereoscopic display regardless of the amount of disparity between the stereo images. We also found that the 3-D CSF at DP≠0 does not differ from the 3-D CSF at DP=0 for DPs and disparities which allow effortless binocular fusion. Therefore, the existing 2-D medical luminance calibration algorithm remains an appropriate tool for calibrating polarized stereoscopic medical displays.

  13. Depth Perception In Remote Stereoscopic Viewing Systems

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B.; Von Sydow, Marika

    1989-01-01

    Report describes theoretical and experimental studies of perception of depth by human operators through stereoscopic video systems. Purpose of such studies to optimize dual-camera configurations used to view workspaces of remote manipulators at distances of 1 to 3 m from cameras. According to analysis, static stereoscopic depth distortion decreased, without decreasing stereoscopitc depth resolution, by increasing camera-to-object and intercamera distances and camera focal length. Further predicts dynamic stereoscopic depth distortion reduced by rotating cameras around center of circle passing through point of convergence of viewing axes and first nodal points of two camera lenses.

  14. An HTML Tool for Production of Interactive Stereoscopic Compositions.

    PubMed

    Chistyakov, Alexey; Soto, Maria Teresa; Martí, Enric; Carrabina, Jordi

    2016-12-01

    The benefits of stereoscopic vision in medical applications were appreciated and have been thoroughly studied for more than a century. The usage of the stereoscopic displays has a proven positive impact on performance in various medical tasks. At the same time the market of 3D-enabled technologies is blooming. New high resolution stereo cameras, TVs, projectors, monitors, and head mounted displays become available. This equipment, completed with a corresponding application program interface (API), could be relatively easy implemented in a system. Such complexes could open new possibilities for medical applications exploiting the stereoscopic depth. This work proposes a tool for production of interactive stereoscopic graphical user interfaces, which could represent a software layer for web-based medical systems facilitating the stereoscopic effect. Further the tool's operation mode and the results of the conducted subjective and objective performance tests will be exposed.

  15. Interlopers 3D: experiences designing a stereoscopic game

    NASA Astrophysics Data System (ADS)

    Weaver, James; Holliman, Nicolas S.

    2014-03-01

    Background In recent years 3D-enabled televisions, VR headsets and computer displays have become more readily available in the home. This presents an opportunity for game designers to explore new stereoscopic game mechanics and techniques that have previously been unavailable in monocular gaming. Aims To investigate the visual cues that are present in binocular and monocular vision, identifying which are relevant when gaming using a stereoscopic display. To implement a game whose mechanics are so reliant on binocular cues that the game becomes impossible or at least very difficult to play in non-stereoscopic mode. Method A stereoscopic 3D game was developed whose objective was to shoot down advancing enemies (the Interlopers) before they reached their destination. Scoring highly required players to make accurate depth judgments and target the closest enemies first. A group of twenty participants played both a basic and advanced version of the game in both monoscopic 2D and stereoscopic 3D. Results The results show that in both the basic and advanced game participants achieved higher scores when playing in stereoscopic 3D. The advanced game showed that by disrupting the depth from motion cue the game became more difficult in monoscopic 2D. Results also show a certain amount of learning taking place over the course of the experiment, meaning that players were able to score higher and finish the game faster over the course of the experiment. Conclusions Although the game was not impossible to play in monoscopic 2D, participants results show that it put them at a significant disadvantage when compared to playing in stereoscopic 3D.

  16. Stereoscopic observations from meteorological satellites

    NASA Astrophysics Data System (ADS)

    Hasler, A. F.; Mack, R.; Negri, A.

    The capability of making stereoscopic observations of clouds from meteorological satellites is a new basic analysis tool with a broad spectrum of applications. Stereoscopic observations from satellites were first made using the early vidicon tube weather satellites (e.g., Ondrejka and Conover [1]). However, the only high quality meteorological stereoscopy from low orbit has been done from Apollo and Skylab, (e.g., Shenk et al. [2] and Black [3], [4]). Stereoscopy from geosynchronous satellites was proposed by Shenk [5] and Bristor and Pichel [6] in 1974 which allowed Minzner et al. [7] to demonstrate the first quantitative cloud height analysis. In 1978 Bryson [8] and desJardins [9] independently developed digital processing techniques to remap stereo images which made possible precision height measurement and spectacular display of stereograms (Hasler et al. [10], and Hasler [11]). In 1980 the Japanese Geosynchronous Satellite (GMS) and the U.S. GOES-West satellite were synchronized to obtain stereo over the central Pacific as described by Fujita and Dodge [12] and in this paper. Recently the authors have remapped images from a Low Earth Orbiter (LEO) to the coordinate system of a Geosynchronous Earth Orbiter (GEO) and obtained stereoscopic cloud height measurements which promise to have quality comparable to previous all GEO stereo. It has also been determined that the north-south imaging scan rate of some GEOs can be slowed or reversed. Therefore the feasibility of obtaining stereoscopic observations world wide from combinations of operational GEO and LEO satellites has been demonstrated. Stereoscopy from satellites has many advantages over infrared techniques for the observation of cloud structure because it depends only on basic geometric relationships. Digital remapping of GEO and LEO satellite images is imperative for precision stereo height measurement and high quality displays because of the curvature of the earth and the large angular separation of the

  17. An optimized web-based approach for collaborative stereoscopic medical visualization

    PubMed Central

    Kaspar, Mathias; Parsad, Nigel M; Silverstein, Jonathan C

    2013-01-01

    Objective Medical visualization tools have traditionally been constrained to tethered imaging workstations or proprietary client viewers, typically part of hospital radiology systems. To improve accessibility to real-time, remote, interactive, stereoscopic visualization and to enable collaboration among multiple viewing locations, we developed an open source approach requiring only a standard web browser with no added client-side software. Materials and Methods Our collaborative, web-based, stereoscopic, visualization system, CoWebViz, has been used successfully for the past 2 years at the University of Chicago to teach immersive virtual anatomy classes. It is a server application that streams server-side visualization applications to client front-ends, comprised solely of a standard web browser with no added software. Results We describe optimization considerations, usability, and performance results, which make CoWebViz practical for broad clinical use. We clarify technical advances including: enhanced threaded architecture, optimized visualization distribution algorithms, a wide range of supported stereoscopic presentation technologies, and the salient theoretical and empirical network parameters that affect our web-based visualization approach. Discussion The implementations demonstrate usability and performance benefits of a simple web-based approach for complex clinical visualization scenarios. Using this approach overcomes technical challenges that require third-party web browser plug-ins, resulting in the most lightweight client. Conclusions Compared to special software and hardware deployments, unmodified web browsers enhance remote user accessibility to interactive medical visualization. Whereas local hardware and software deployments may provide better interactivity than remote applications, our implementation demonstrates that a simplified, stable, client approach using standard web browsers is sufficient for high quality three

  18. Stereoscopic 3D video games and their effects on engagement

    NASA Astrophysics Data System (ADS)

    Hogue, Andrew; Kapralos, Bill; Zerebecki, Chris; Tawadrous, Mina; Stanfield, Brodie; Hogue, Urszula

    2012-03-01

    With television manufacturers developing low-cost stereoscopic 3D displays, a large number of consumers will undoubtedly have access to 3D-capable televisions at home. The availability of 3D technology places the onus on content creators to develop interesting and engaging content. While the technology of stereoscopic displays and content generation are well understood, there are many questions yet to be answered surrounding its effects on the viewer. Effects of stereoscopic display on passive viewers for film are known, however video games are fundamentally different since the viewer/player is actively (rather than passively) engaged in the content. Questions of how stereoscopic viewing affects interaction mechanics have previously been studied in the context of player performance but very few have attempted to quantify the player experience to determine whether stereoscopic 3D has a positive or negative influence on their overall engagement. In this paper we present a preliminary study of the effects stereoscopic 3D have on player engagement in video games. Participants played a video game in two conditions, traditional 2D and stereoscopic 3D and their engagement was quantified using a previously validated self-reporting tool. The results suggest that S3D has a positive effect on immersion, presence, flow, and absorption.

  19. Stereoscopic Integrated Imaging Goggles for Multimodal Intraoperative Image Guidance

    PubMed Central

    Mela, Christopher A.; Patterson, Carrie; Thompson, William K.; Papay, Francis; Liu, Yang

    2015-01-01

    We have developed novel stereoscopic wearable multimodal intraoperative imaging and display systems entitled Integrated Imaging Goggles for guiding surgeries. The prototype systems offer real time stereoscopic fluorescence imaging and color reflectance imaging capacity, along with in vivo handheld microscopy and ultrasound imaging. With the Integrated Imaging Goggle, both wide-field fluorescence imaging and in vivo microscopy are provided. The real time ultrasound images can also be presented in the goggle display. Furthermore, real time goggle-to-goggle stereoscopic video sharing is demonstrated, which can greatly facilitate telemedicine. In this paper, the prototype systems are described, characterized and tested in surgeries in biological tissues ex vivo. We have found that the system can detect fluorescent targets with as low as 60 nM indocyanine green and can resolve structures down to 0.25 mm with large FOV stereoscopic imaging. The system has successfully guided simulated cancer surgeries in chicken. The Integrated Imaging Goggle is novel in 4 aspects: it is (a) the first wearable stereoscopic wide-field intraoperative fluorescence imaging and display system, (b) the first wearable system offering both large FOV and microscopic imaging simultaneously, (c) the first wearable system that offers both ultrasound imaging and fluorescence imaging capacities, and (d) the first demonstration of goggle-to-goggle communication to share stereoscopic views for medical guidance. PMID:26529249

  20. Stereoscopic depth increases intersubject correlations of brain networks.

    PubMed

    Gaebler, Michael; Biessmann, Felix; Lamke, Jan-Peter; Müller, Klaus-Robert; Walter, Henrik; Hetzer, Stefan

    2014-10-15

    Three-dimensional movies presented via stereoscopic displays have become more popular in recent years aiming at a more engaging viewing experience. However, neurocognitive processes associated with the perception of stereoscopic depth in complex and dynamic visual stimuli remain understudied. Here, we investigate the influence of stereoscopic depth on both neurophysiology and subjective experience. Using multivariate statistical learning methods, we compare the brain activity of subjects when freely watching the same movies in 2D and in 3D. Subjective reports indicate that 3D movies are more strongly experienced than 2D movies. On the neural level, we observe significantly higher intersubject correlations of cortical networks when subjects are watching 3D movies relative to the same movies in 2D. We demonstrate that increases in intersubject correlations of brain networks can serve as neurophysiological marker for stereoscopic depth and for the strength of the viewing experience. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Factor VII assay

    MedlinePlus

    Stable factor; Proconvertin; Autoprothrombin I ... be caused by an abnormally low level of factor VII. ... Decreased factor VII activity may be related to: Deficiency of factor VII Disorder in which the proteins that control ...

  2. Stereoscopic depth perception varies with hues

    NASA Astrophysics Data System (ADS)

    Chen, Zaiqing; Shi, Junsheng; Tai, Yonghang; Yun, Lijun

    2012-09-01

    The contribution of color information to stereopsis is controversial, and whether the stereoscopic depth perception varies with chromaticity is ambiguous. This study examined the changes in depth perception caused by hue variations. Based on the fact that a greater disparity range indicates more efficient stereoscopic perception, the effect of hue variations on depth perception was evaluated through the disparity range with random-dot stereogram stimuli. The disparity range was obtained by constant-stimulus method for eight chromaticity points sampled from the CIE 1931 chromaticity diagram. Eight sample points include four main color hues: red, yellow, green, and blue at two levels of chroma. The results show that the disparity range for the yellow hue is greater than the red hue, the latter being greater than the blue hue and the disparity range for green hue is smallest. We conclude that the perceived depth is not the same for different hues for a given size of disparity. We suggest that the stereoscopic depth perception can vary with chromaticity.

  3. Usability of stereoscopic view in teleoperation

    NASA Astrophysics Data System (ADS)

    Boonsuk, Wutthigrai

    2015-03-01

    Recently, there are tremendous growths in the area of 3D stereoscopic visualization. The 3D stereoscopic visualization technology has been used in a growing number of consumer products such as the 3D televisions and the 3D glasses for gaming systems. This technology refers to the idea that human brain develops depth of perception by retrieving information from the two eyes. Our brain combines the left and right images on the retinas and extracts depth information. Therefore, viewing two video images taken at slightly distance apart as shown in Figure 1 can create illusion of depth [8]. Proponents of this technology argue that the stereo view of 3D visualization increases user immersion and performance as more information is gained through the 3D vision as compare to the 2D view. However, it is still uncertain if additional information gained from the 3D stereoscopic visualization can actually improve user performance in real world situations such as in the case of teleoperation.

  4. Psychometric Assessment of Stereoscopic Head-Mounted Displays

    DTIC Science & Technology

    2016-06-29

    Journal Article 3. DATES COVERED (From – To) Jan 2015 - Dec 2015 4. TITLE AND SUBTITLE PSYCHOMETRIC ASSESSMENT OF STEREOSCOPIC HEAD- MOUNTED DISPLAYS...to render an immersive three-dimensional constructive environment. The purpose of this effort was to quantify the impact of aircrew vision on an...simulated tasks requiring precise depth discrimination. This work will provide an example validation method for future stereoscopic virtual immersive

  5. [Effects of stereoscopic cultivation on photosynthetic characteristics and growth of Tulipa edulis].

    PubMed

    Sun, Yuan; Guo, Qiao-Sheng; Zhu, Zai-Biao; Lin, Jian-Luo; Zhou, Bo-Ya; Zhao, Min-Jie

    2016-06-01

    The effect of stereoscopic cultivation on the growth, photosynthetic characteristics and yield of Tulipa edulis was studied to explore the feasibility of stereoscopic cultivation on efficient cultivation of T.edulis. Total leaf area and photosynthetic parameters of T.edulis under stereoscopic cultivation (the upper, middle and the lower layers ) and the control were measured using LI-3100 leaf area meter and LI-6400XT photosynthesis system in the growing peak period of T.edulis.Plant biomass and biomass allocation were also determined.In addition, the bulb regeneration and yield of T.edulis were measured in the harvesting time.The results indicated that in the middle layer of stereoscopic cultivation, leaf biomass proportion was the highest, but total bulb fresh and dry weight and output growth (fresh weight) were the lowest among the treatments.And total bulb fresh weight in the middle of stereoscopic cultivation reduced significantly, by 22.84%, compared with the control.Light intensity in the lower layer of stereoscopic cultivation was moderate, in which T.edulis net photosynthetic rate and water use efficiency were higher than those of the other layers of stereoscopic cultivation, and bulb biomass proportion was the highest in all the treatments.No significant difference was detected in the total bulb fresh weight, dry weight and output growth (fresh weight) between the middle layer of stereoscopic cultivation and the control.In general, there was no significant difference in the growth status of T.edulis between stereoscopic cultivation and the control.Stereoscopic cultivation increased the yield of T.edulis by 161.66% in fresh weight and 141.35% in dry weight compared with the control in the condition of the same land area, respectively.In conclusion, stereoscopic cultivation can improve space utilization, increase the production, and achieve the high density cultivation of T.edulis. Copyright© by the Chinese Pharmaceutical Association.

  6. Stereoscopic advantages for vection induced by radial, circular, and spiral optic flows.

    PubMed

    Palmisano, Stephen; Summersby, Stephanie; Davies, Rodney G; Kim, Juno

    2016-11-01

    Although observer motions project different patterns of optic flow to our left and right eyes, there has been surprisingly little research into potential stereoscopic contributions to self-motion perception. This study investigated whether visually induced illusory self-motion (i.e., vection) is influenced by the addition of consistent stereoscopic information to radial, circular, and spiral (i.e., combined radial + circular) patterns of optic flow. Stereoscopic vection advantages were found for radial and spiral (but not circular) flows when monocular motion signals were strong. Under these conditions, stereoscopic benefits were greater for spiral flow than for radial flow. These effects can be explained by differences in the motion aftereffects generated by these displays, which suggest that the circular motion component in spiral flow selectively reduced adaptation to stereoscopic motion-in-depth. Stereoscopic vection advantages were not observed for circular flow when monocular motion signals were strong, but emerged when monocular motion signals were weakened. These findings show that stereoscopic information can contribute to visual self-motion perception in multiple ways.

  7. Interactive floating windows: a new technique for stereoscopic video games

    NASA Astrophysics Data System (ADS)

    Zerebecki, Chris; Stanfield, Brodie; Tawadrous, Mina; Buckstein, Daniel; Hogue, Andrew; Kapralos, Bill

    2012-03-01

    The film industry has a long history of creating compelling experiences in stereoscopic 3D. Recently, the video game as an artistic medium has matured into an effective way to tell engaging and immersive stories. Given the current push to bring stereoscopic 3D technology into the consumer market there is considerable interest to develop stereoscopic 3D video games. Game developers have largely ignored the need to design their games specifically for stereoscopic 3D and have thus relied on automatic conversion and driver technology. Game developers need to evaluate solutions used in other media, such as film, to correct perceptual problems such as window violations, and modify or create new solutions to work within an interactive framework. In this paper we extend the dynamic floating window technique into the interactive domain enabling the player to position a virtual window in space. Interactively changing the position, size, and the 3D rotation of the virtual window, objects can be made to 'break the mask' dramatically enhancing the stereoscopic effect. By demonstrating that solutions from the film industry can be extended into the interactive space, it is our hope that this initiates further discussion in the game development community to strengthen their story-telling mechanisms in stereoscopic 3D games.

  8. Characterization of crosstalk in stereoscopic display devices.

    PubMed

    Zafar, Fahad; Badano, Aldo

    2014-12-01

    Many different types of stereoscopic display devices are used for commercial and research applications. Stereoscopic displays offer the potential to improve performance in detection tasks for medical imaging diagnostic systems. Due to the variety of stereoscopic display technologies, it remains unclear how these compare with each other for detection and estimation tasks. Different stereo devices have different performance trade-offs due to their display characteristics. Among them, crosstalk is known to affect observer perception of 3D content and might affect detection performance. We measured and report the detailed luminance output and crosstalk characteristics for three different types of stereoscopic display devices. We recorded the effect of other issues on recorded luminance profiles such as viewing angle, use of different eye wear, and screen location. Our results show that the crosstalk signature for viewing 3D content can vary considerably when using different types of 3D glasses for active stereo displays. We also show that significant differences are present in crosstalk signatures when varying the viewing angle from 0 degrees to 20 degrees for a stereo mirror 3D display device. Our detailed characterization can help emulate the effect of crosstalk in conducting computational observer image quality assessment evaluations that minimize costly and time-consuming human reader studies.

  9. Stereoscopic medical imaging collaboration system

    NASA Astrophysics Data System (ADS)

    Okuyama, Fumio; Hirano, Takenori; Nakabayasi, Yuusuke; Minoura, Hirohito; Tsuruoka, Shinji

    2007-02-01

    The computerization of the clinical record and the realization of the multimedia have brought improvement of the medical service in medical facilities. It is very important for the patients to obtain comprehensible informed consent. Therefore, the doctor should plainly explain the purpose and the content of the diagnoses and treatments for the patient. We propose and design a Telemedicine Imaging Collaboration System which presents a three dimensional medical image as X-ray CT, MRI with stereoscopic image by using virtual common information space and operating the image from a remote location. This system is composed of two personal computers, two 15 inches stereoscopic parallax barrier type LCD display (LL-151D, Sharp), one 1Gbps router and 1000base LAN cables. The software is composed of a DICOM format data transfer program, an operation program of the images, the communication program between two personal computers and a real time rendering program. Two identical images of 512×768 pixcels are displayed on two stereoscopic LCD display, and both images show an expansion, reduction by mouse operation. This system can offer a comprehensible three-dimensional image of the diseased part. Therefore, the doctor and the patient can easily understand it, depending on their needs.

  10. Cosmic cookery: making a stereoscopic 3D animated movie

    NASA Astrophysics Data System (ADS)

    Holliman, Nick; Baugh, Carlton; Frenk, Carlos; Jenkins, Adrian; Froner, Barbara; Hassaine, Djamel; Helly, John; Metcalfe, Nigel; Okamoto, Takashi

    2006-02-01

    This paper describes our experience making a short stereoscopic movie visualizing the development of structure in the universe during the 13.7 billion years from the Big Bang to the present day. Aimed at a general audience for the Royal Society's 2005 Summer Science Exhibition, the movie illustrates how the latest cosmological theories based on dark matter and dark energy are capable of producing structures as complex as spiral galaxies and allows the viewer to directly compare observations from the real universe with theoretical results. 3D is an inherent feature of the cosmology data sets and stereoscopic visualization provides a natural way to present the images to the viewer, in addition to allowing researchers to visualize these vast, complex data sets. The presentation of the movie used passive, linearly polarized projection onto a 2m wide screen but it was also required to playback on a Sharp RD3D display and in anaglyph projection at venues without dedicated stereoscopic display equipment. Additionally lenticular prints were made from key images in the movie. We discuss the following technical challenges during the stereoscopic production process; 1) Controlling the depth presentation, 2) Editing the stereoscopic sequences, 3) Generating compressed movies in display specific formats. We conclude that the generation of high quality stereoscopic movie content using desktop tools and equipment is feasible. This does require careful quality control and manual intervention but we believe these overheads are worthwhile when presenting inherently 3D data as the result is significantly increased impact and better understanding of complex 3D scenes.

  11. The compatibility of consumer DLP projectors with time-sequential stereoscopic 3D visualisation

    NASA Astrophysics Data System (ADS)

    Woods, Andrew J.; Rourke, Tegan

    2007-02-01

    A range of advertised "Stereo-Ready" DLP projectors are now available in the market which allow high-quality flickerfree stereoscopic 3D visualization using the time-sequential stereoscopic display method. The ability to use a single projector for stereoscopic viewing offers a range of advantages, including extremely good stereoscopic alignment, and in some cases, portability. It has also recently become known that some consumer DLP projectors can be used for timesequential stereoscopic visualization, however it was not well understood which projectors are compatible and incompatible, what display modes (frequency and resolution) are compatible, and what stereoscopic display quality attributes are important. We conducted a study to test a wide range of projectors for stereoscopic compatibility. This paper reports on the testing of 45 consumer DLP projectors of widely different specifications (brand, resolution, brightness, etc). The projectors were tested for stereoscopic compatibility with various video formats (PAL, NTSC, 480P, 576P, and various VGA resolutions) and video input connections (composite, SVideo, component, and VGA). Fifteen projectors were found to work well at up to 85Hz stereo in VGA mode. Twenty three projectors would work at 60Hz stereo in VGA mode.

  12. Calculation of 3D Coordinates of a Point on the Basis of a Stereoscopic System

    NASA Astrophysics Data System (ADS)

    Mussabayev, R. R.; Kalimoldayev, M. N.; Amirgaliyev, Ye. N.; Tairova, A. T.; Mussabayev, T. R.

    2018-05-01

    The solution of three-dimensional (3D) coordinate calculation task for a material point is considered. Two flat images (a stereopair) which correspond to the left and to the right viewpoints of a 3D scene are used for this purpose. The stereopair is obtained using two cameras with parallel optical axes. The analytical formulas for calculating 3D coordinates of a material point in the scene were obtained on the basis of analysis of the stereoscopic system optical and geometrical schemes. The detailed presentation of the algorithmic and hardware realization of the given method was discussed with the the practical. The practical module was recommended for the determination of the optical system unknown parameters. The series of experimental investigations were conducted for verification of theoretical results. During these experiments the minor inaccuracies were occurred by space distortions in the optical system and by it discrecity. While using the high quality stereoscopic system, the existing calculation inaccuracy enables to apply the given method for the wide range of practical tasks.

  13. Interactive 2D to 3D stereoscopic image synthesis

    NASA Astrophysics Data System (ADS)

    Feldman, Mark H.; Lipton, Lenny

    2005-03-01

    Advances in stereoscopic display technologies, graphic card devices, and digital imaging algorithms have opened up new possibilities in synthesizing stereoscopic images. The power of today"s DirectX/OpenGL optimized graphics cards together with adapting new and creative imaging tools found in software products such as Adobe Photoshop, provide a powerful environment for converting planar drawings and photographs into stereoscopic images. The basis for such a creative process is the focus of this paper. This article presents a novel technique, which uses advanced imaging features and custom Windows-based software that utilizes the Direct X 9 API to provide the user with an interactive stereo image synthesizer. By creating an accurate and interactive world scene with moveable and flexible depth map altered textured surfaces, perspective stereoscopic cameras with both visible frustums and zero parallax planes, a user can precisely model a virtual three-dimensional representation of a real-world scene. Current versions of Adobe Photoshop provide a creative user with a rich assortment of tools needed to highlight elements of a 2D image, simulate hidden areas, and creatively shape them for a 3D scene representation. The technique described has been implemented as a Photoshop plug-in and thus allows for a seamless transition of these 2D image elements into 3D surfaces, which are subsequently rendered to create stereoscopic views.

  14. Stereoscopic display of 3D models for design visualization

    NASA Astrophysics Data System (ADS)

    Gilson, Kevin J.

    2006-02-01

    Advances in display technology and 3D design visualization applications have made real-time stereoscopic visualization of architectural and engineering projects a reality. Parsons Brinkerhoff (PB) is a transportation consulting firm that has used digital visualization tools from their inception and has helped pioneer the application of those tools to large scale infrastructure projects. PB is one of the first Architecture/Engineering/Construction (AEC) firms to implement a CAVE- an immersive presentation environment that includes stereoscopic rear-projection capability. The firm also employs a portable stereoscopic front-projection system, and shutter-glass systems for smaller groups. PB is using commercial real-time 3D applications in combination with traditional 3D modeling programs to visualize and present large AEC projects to planners, clients and decision makers in stereo. These presentations create more immersive and spatially realistic presentations of the proposed designs. This paper will present the basic display tools and applications, and the 3D modeling techniques PB is using to produce interactive stereoscopic content. The paper will discuss several architectural and engineering design visualizations we have produced.

  15. Enduring stereoscopic motion aftereffects induced by prolonged adaptation.

    PubMed

    Bowd, C; Rose, D; Phinney, R E; Patterson, R

    1996-11-01

    This study investigated the effects of prolonged adaptation on the recovery of the stereoscopic motion aftereffect (adaptation induced by moving binocular disparity information). The adapting and test stimuli were stereoscopic grating patterns created from disparity, embedded in dynamic random-dot stereograms. Motion aftereffects induced by luminance stimuli were included in the study for comparison. Adaptation duration was either 1, 2, 4, 8, 16, 32 or 64 min and the duration of the ensuing aftereffect was the variable of interest. The results showed that aftereffect duration was proportional to the square root of adaptation duration for both stereoscopic and luminance stimuli; on log-log axes, the relation between aftereffect duration and adaptation duration was a power law with the slope near 0.5 in both cases. For both kinds of stimuli, there was no sign of adaptation saturation even at the longest adaptation duration.

  16. Visual Attention Modeling for Stereoscopic Video: A Benchmark and Computational Model.

    PubMed

    Fang, Yuming; Zhang, Chi; Li, Jing; Lei, Jianjun; Perreira Da Silva, Matthieu; Le Callet, Patrick

    2017-10-01

    In this paper, we investigate the visual attention modeling for stereoscopic video from the following two aspects. First, we build one large-scale eye tracking database as the benchmark of visual attention modeling for stereoscopic video. The database includes 47 video sequences and their corresponding eye fixation data. Second, we propose a novel computational model of visual attention for stereoscopic video based on Gestalt theory. In the proposed model, we extract the low-level features, including luminance, color, texture, and depth, from discrete cosine transform coefficients, which are used to calculate feature contrast for the spatial saliency computation. The temporal saliency is calculated by the motion contrast from the planar and depth motion features in the stereoscopic video sequences. The final saliency is estimated by fusing the spatial and temporal saliency with uncertainty weighting, which is estimated by the laws of proximity, continuity, and common fate in Gestalt theory. Experimental results show that the proposed method outperforms the state-of-the-art stereoscopic video saliency detection models on our built large-scale eye tracking database and one other database (DML-ITRACK-3D).

  17. Production and evaluation of stereoscopic video presentation in surgical training

    NASA Astrophysics Data System (ADS)

    Ilgner, Justus; Kawai, Takashi; Westhofen, Martin; Shibata, Takashi

    2004-05-01

    Stereoscopic video teaching can facilitate understanding for current minimally-invasive operative techniques. This project was created to set up a digital stereoscopic teaching environment for training of ENT residents and medical students. We recorded three ENT operative procedures (tympanoplasty, paranasal sinus operation and laser chordectomy) at the University Hospital Aachen. The material was edited stereoscopically at the Waseda University and converted into a streaming 3-D video format, which does not depend on PAL or NTSC signal standards. Video clips were evaluated by 5 ENT specialists and 11 residents in single sessions on an LCD monitor (8) and a CRT monitor (8). Emphasis was laid on depth perception, visual fatigue and time to achieve stereoscopic impression. Qualitative results were recorded on a visual analogue scale, ranging from 1 (excellent) to 5 (bad). The overall impression was rated 2,06 to 3,13 in the LCD group and 2,0 to 2,62 in the CRT group. The depth impression was rated 1,63 to 2,88 (LCD) and 1,63 to 2,25 (CRT). Stereoscopic video teaching was regarded as useful in ENT training by all participants. Further points for evaluation will be the quantification of depth information as well as the information gain in teaching junior colleagues.

  18. Efficient stereoscopic contents file format on the basis of ISO base media file format

    NASA Astrophysics Data System (ADS)

    Kim, Kyuheon; Lee, Jangwon; Suh, Doug Young; Park, Gwang Hoon

    2009-02-01

    A lot of 3D contents haven been widely used for multimedia services, however, real 3D video contents have been adopted for a limited applications such as a specially designed 3D cinema. This is because of the difficulty of capturing real 3D video contents and the limitation of display devices available in a market. However, diverse types of display devices for stereoscopic video contents for real 3D video contents have been recently released in a market. Especially, a mobile phone with a stereoscopic camera has been released in a market, which provides a user as a consumer to have more realistic experiences without glasses, and also, as a content creator to take stereoscopic images or record the stereoscopic video contents. However, a user can only store and display these acquired stereoscopic contents with his/her own devices due to the non-existence of a common file format for these contents. This limitation causes a user not share his/her contents with any other users, which makes it difficult the relevant market to stereoscopic contents is getting expanded. Therefore, this paper proposes the common file format on the basis of ISO base media file format for stereoscopic contents, which enables users to store and exchange pure stereoscopic contents. This technology is also currently under development for an international standard of MPEG as being called as a stereoscopic video application format.

  19. The ghost of Helioth and his stereoscope: the return of a phantom.

    PubMed

    Wade, Nicholas J

    2012-01-01

    Among the myths surrounding the invention of the stereoscope, that of Helioth stands as a supreme example of shoddy scholarship and its subsequent dissemination. Helioth was said to have made a simple stereoscope before Wheatstone presented his mirror stereoscope to the public in 1838. There is no evidence of Helioth's existence prior to a report in the mid-twentieth century, and despite attempts to dispel his ghost it has recently resurfaced.

  20. The rendering context for stereoscopic 3D web

    NASA Astrophysics Data System (ADS)

    Chen, Qinshui; Wang, Wenmin; Wang, Ronggang

    2014-03-01

    3D technologies on the Web has been studied for many years, but they are basically monoscopic 3D. With the stereoscopic technology gradually maturing, we are researching to integrate the binocular 3D technology into the Web, creating a stereoscopic 3D browser that will provide users with a brand new experience of human-computer interaction. In this paper, we propose a novel approach to apply stereoscopy technologies to the CSS3 3D Transforms. Under our model, each element can create or participate in a stereoscopic 3D rendering context, in which 3D Transforms such as scaling, translation and rotation, can be applied and be perceived in a truly 3D space. We first discuss the underlying principles of stereoscopy. After that we discuss how these principles can be applied to the Web. A stereoscopic 3D browser with backward compatibility is also created for demonstration purposes. We take advantage of the open-source WebKit project, integrating the 3D display ability into the rendering engine of the web browser. For each 3D web page, our 3D browser will create two slightly different images, each representing the left-eye view and right-eye view, both to be combined on the 3D display to generate the illusion of depth. And as the result turns out, elements can be manipulated in a truly 3D space.

  1. A Review on Stereoscopic 3D: Home Entertainment for the Twenty First Century

    NASA Astrophysics Data System (ADS)

    Karajeh, Huda; Maqableh, Mahmoud; Masa'deh, Ra'ed

    2014-12-01

    In the last few years, stereoscopic developed very rapidly and employed in many different fields such as entertainment. Due to the importance of entertainment aspect of stereoscopic 3D (S3D) applications, a review of the current state of S3D development in entertainment technology is conducted. In this paper, a novel survey of the stereoscopic entertainment aspects is presented by discussing the significant development of a 3D cinema, the major development of 3DTV, the issues related to 3D video content and 3D video games. Moreover, we reviewed some problems that can be caused in the viewers' visual system from watching stereoscopic contents. Some stereoscopic viewers are not satisfied as they are frustrated from wearing glasses, have visual fatigue, complain from unavailability of 3D contents, and/or complain from some sickness. Therefore, we will discuss stereoscopic visual discomfort and to what extend the viewer will have an eye fatigue while watching 3D contents or playing 3D games. The suggested solutions in the literature for this problem are discussed.

  2. An interactive in-game approach to user adjustment of stereoscopic 3D settings

    NASA Astrophysics Data System (ADS)

    Tawadrous, Mina; Hogue, Andrew; Kapralos, Bill; Collins, Karen

    2013-03-01

    Given the popularity of 3D film, content developers have been creating customizable stereoscopic 3D experiences for the user to enjoy at home. Stereoscopic 3D game developers often offer a `white box' approach whereby far too many controls and settings are exposed to the average consumer who may have little knowledge or interest to correctly adjust these settings. Improper settings can lead to users being uncomfortable or unimpressed with their own user-defined stereoscopic 3D experience. We have begun investigating interactive approaches to in-game adjustment of the various stereoscopic 3D parameters to reduce the reliance on the user doing so and thefore creating a more pleasurable stereoscopic 3D experience. In this paper, we describe a preliminary technique for interactively calibrating the various stereoscopic 3D parameters and we compare this interface with the typical slider-based control interface game developers utilize in commercial S3D games. Inspired by standard testing methodologies experienced at an optometrist, we've created a split-screen game with the same stereoscopic 3D game running in both screens, but with different interaxial distances. We expect that the interactive nature of the calibration will impact the final game experience providing us with an indication of whether in-game, interactive, S3D parameter calibration is a mechanism that game developers should adopt.

  3. Semi-autonomous wheelchair system using stereoscopic cameras.

    PubMed

    Nguyen, Jordan S; Nguyen, Thanh H; Nguyen, Hung T

    2009-01-01

    This paper is concerned with the design and development of a semi-autonomous wheelchair system using stereoscopic cameras to assist hands-free control technologies for severely disabled people. The stereoscopic cameras capture an image from both the left and right cameras, which are then processed with a Sum of Absolute Differences (SAD) correlation algorithm to establish correspondence between image features in the different views of the scene. This is used to produce a stereo disparity image containing information about the depth of objects away from the camera in the image. A geometric projection algorithm is then used to generate a 3-Dimensional (3D) point map, placing pixels of the disparity image in 3D space. This is then converted to a 2-Dimensional (2D) depth map allowing objects in the scene to be viewed and a safe travel path for the wheelchair to be planned and followed based on the user's commands. This assistive technology utilising stereoscopic cameras has the purpose of automated obstacle detection, path planning and following, and collision avoidance during navigation. Experimental results obtained in an indoor environment displayed the effectiveness of this assistive technology.

  4. Is eye damage caused by stereoscopic displays?

    NASA Astrophysics Data System (ADS)

    Mayer, Udo; Neumann, Markus D.; Kubbat, Wolfgang; Landau, Kurt

    2000-05-01

    A normal developing child will achieve emmetropia in youth and maintain it. Thereby cornea, lens and axial length of the eye grow astonishingly coordinated. In the last years research has evidenced that this coordinated growing process is a visually controlled closed loop. The mechanism has been studied particularly in animals. It was found that the growth of the axial length of the eyeball is controlled by image focus information from the retina. It was shown that maladjustment can occur by this visually-guided growth control mechanism that result in ametropia. Thereby it has been proven that e.g. short-sightedness is not only caused by heredity, but is acquired under certain visual conditions. It is shown that these conditions are similar to the conditions of viewing stereoscopic displays where the normal accommodation convergence coupling is disjoint. An evaluation is given of the potential of damaging the eyes by viewing stereoscopic displays. Concerning this, different viewing methods for stereoscopic displays are evaluated. Moreover, clues are given how the environment and display conditions shall be set and what users shall be chosen to minimize the risk of eye damages.

  5. Stereoscopic Perception of Women in Real and Virtual Environments: A Study towards Educational Neuroscience

    ERIC Educational Resources Information Center

    Zacharis, Georgios S.; Mikropoulos, Tassos A.; Priovolou, Chryssi

    2013-01-01

    Previous studies report the involvement of specific brain activation in stereoscopic vision and the perception of depth information. This work presents the first comparative results of adult women on the effects of stereoscopic perception in three different static environments; a real, a two dimensional (2D) and a stereoscopic three dimensional…

  6. Analysis of brain activity and response during monoscopic and stereoscopic visualization

    NASA Astrophysics Data System (ADS)

    Calore, Enrico; Folgieri, Raffaella; Gadia, Davide; Marini, Daniele

    2012-03-01

    Stereoscopic visualization in cinematography and Virtual Reality (VR) creates an illusion of depth by means of two bidimensional images corresponding to different views of a scene. This perceptual trick is used to enhance the emotional response and the sense of presence and immersivity of the observers. An interesting question is if and how it is possible to measure and analyze the level of emotional involvement and attention of the observers during a stereoscopic visualization of a movie or of a virtual environment. The research aims represent a challenge, due to the large number of sensorial, physiological and cognitive stimuli involved. In this paper we begin this research by analyzing possible differences in the brain activity of subjects during the viewing of monoscopic or stereoscopic contents. To this aim, we have performed some preliminary experiments collecting electroencephalographic (EEG) data of a group of users using a Brain- Computer Interface (BCI) during the viewing of stereoscopic and monoscopic short movies in a VR immersive installation.

  7. Tele-transmission of stereoscopic images of the optic nerve head in glaucoma via Internet.

    PubMed

    Bergua, Antonio; Mardin, Christian Y; Horn, Folkert K

    2009-06-01

    The objective was to describe an inexpensive system to visualize stereoscopic photographs of the optic nerve head on computer displays and to transmit such images via the Internet for collaborative research or remote clinical diagnosis in glaucoma. Stereoscopic images of glaucoma patients were digitized and stored in a file format (joint photographic stereoimage [jps]) containing all three-dimensional information for both eyes on an Internet Web site (www.trizax.com). The size of jps files was between 0.4 to 1.4 MB (corresponding to a diagonal stereo image size between 900 and 1400 pixels) suitable for Internet protocols. A conventional personal computer system equipped with wireless stereoscopic LCD shutter glasses and a CRT-monitor with high refresh rate (120 Hz) can be used to obtain flicker-free stereo visualization of true-color images with high resolution. Modern thin-film transistor-LCD displays in combination with inexpensive red-cyan goggles achieve stereoscopic visualization with the same resolution but reduced color quality and contrast. The primary aim of our study was met to transmit stereoscopic images via the Internet. Additionally, we found that with both stereoscopic visualization techniques, cup depth, neuroretinal rim shape, and slope of the inner wall of the optic nerve head, can be qualitatively better perceived and interpreted than with monoscopic images. This study demonstrates high-quality and low-cost Internet transmission of stereoscopic images of the optic nerve head from glaucoma patients. The technique allows exchange of stereoscopic images and can be applied to tele-diagnostic and glaucoma research.

  8. Analysis on the 3D crosstalk in stereoscopic display

    NASA Astrophysics Data System (ADS)

    Choi, Hee-Jin

    2010-11-01

    Nowadays, with the rapid progresses in flat panel display (FPD) technologies, the three-dimensional (3D) display is now becoming a next mainstream of display market. Among the various 3D display techniques, the stereoscopic 3D display shows different left/right images for each eye of observer using special glasses and is the most popular 3D technique with the advantages of low price and high 3D resolution. However, current stereoscopic 3D displays suffer with the 3D crosstalk which means the interference between the left eye mage and right eye images since it degrades the quality of 3D image severely. In this paper, the meaning and causes of the 3D crosstalk in stereoscopic 3D display are introduced and the pre-proposed methods of 3D crosstalk measurement vision science are reviewed. Based on them The threshold of 3D crosstalk to realize a 3D display with no degradation is analyzed.

  9. Recording stereoscopic 3D neurosurgery with a head-mounted 3D camera system.

    PubMed

    Lee, Brian; Chen, Brian R; Chen, Beverly B; Lu, James Y; Giannotta, Steven L

    2015-06-01

    Stereoscopic three-dimensional (3D) imaging can present more information to the viewer and further enhance the learning experience over traditional two-dimensional (2D) video. Most 3D surgical videos are recorded from the operating microscope and only feature the crux, or the most important part of the surgery, leaving out other crucial parts of surgery including the opening, approach, and closing of the surgical site. In addition, many other surgeries including complex spine, trauma, and intensive care unit procedures are also rarely recorded. We describe and share our experience with a commercially available head-mounted stereoscopic 3D camera system to obtain stereoscopic 3D recordings of these seldom recorded aspects of neurosurgery. The strengths and limitations of using the GoPro(®) 3D system as a head-mounted stereoscopic 3D camera system in the operating room are reviewed in detail. Over the past several years, we have recorded in stereoscopic 3D over 50 cranial and spinal surgeries and created a library for education purposes. We have found the head-mounted stereoscopic 3D camera system to be a valuable asset to supplement 3D footage from a 3D microscope. We expect that these comprehensive 3D surgical videos will become an important facet of resident education and ultimately lead to improved patient care.

  10. Stereoscopic image production: live, CGI, and integration

    NASA Astrophysics Data System (ADS)

    Criado, Enrique

    2006-02-01

    This paper shortly describes part of the experience gathered in more than 10 years of stereoscopic movie production, some of the most common problems found and the solutions, with more or less fortune, we applied to solve those problems. Our work is mainly focused in the entertainment market, theme parks, museums, and other cultural related locations and events. In our movies, we have been forced to develop our own devices to permit correct stereo shooting (stereoscopic rigs) or stereo monitoring (real-time), and to solve problems found with conventional film editing, compositing and postproduction software. Here, we discuss stereo lighting, monitoring, special effects, image integration (using dummies and more), stereo-camera parameters, and other general 3-D movie production aspects.

  11. Generating Stereoscopic Television Images With One Camera

    NASA Technical Reports Server (NTRS)

    Coan, Paul P.

    1996-01-01

    Straightforward technique for generating stereoscopic television images involves use of single television camera translated laterally between left- and right-eye positions. Camera acquires one of images (left- or right-eye image), and video signal from image delayed while camera translated to position where it acquires other image. Length of delay chosen so both images displayed simultaneously or as nearly simultaneously as necessary to obtain stereoscopic effect. Technique amenable to zooming in on small areas within broad scenes. Potential applications include three-dimensional viewing of geological features and meteorological events from spacecraft and aircraft, inspection of workpieces moving along conveyor belts, and aiding ground and water search-and-rescue operations. Also used to generate and display imagery for public education and general information, and possible for medical purposes.

  12. Case study: using a stereoscopic display for mission planning

    NASA Astrophysics Data System (ADS)

    Kleiber, Michael; Winkelholz, Carsten

    2009-02-01

    This paper reports on the results of a study investigating the benefits of using an autostereoscopic display in the training targeting process of the Germain Air Force. The study examined how stereoscopic 3D visualizations can help to improve flight path planning and the preparation of a mission in general. An autostereoscopic display was used because it allows the operator to perceive the stereoscopic images without shutter glasses which facilitates the integration into a workplace with conventional 2D monitors and arbitrary lighting conditions.

  13. Stereoscopic Viewing Can Induce Changes in the CA/C Ratio.

    PubMed

    Neveu, Pascaline; Roumes, Corinne; Philippe, Matthieu; Fuchs, Philippe; Priot, Anne-Emmanuelle

    2016-08-01

    Stereoscopic displays challenge the neural cross-coupling between accommodation and vergence by inducing a constant accommodative demand and a varying vergence demand. Stereoscopic viewing calls for a decrease in the gain of vergence accommodation, which is the accommodation caused by vergence, quantified by using the convergence-accommodation to convergence (CA/C) ratio. However, its adaptability is still a subject of debate. Cross-coupling (CA/C and AC/A ratios) and tonic components of vergence and accommodation were assessed in 12 participants (27.5 ± 5 years, stereoacuity better than 60 arc seconds, 6/6 acuity with corrected refractive error) before and after a 20-minute exposure to stereoscopic viewing. During stimulation, vergence demand oscillated from 1 to 3 meter angles along a virtual sagittal line in sinusoidal movements, while accommodative demand was fixed at 1.5 diopters. Results showed a decreased CA/C ratio (-10.36%, df = 10, t = 2.835, P = 0.018), with no change in the AC/A ratio (P = 0.090), tonic vergence (P = 0.708), and tonic accommodation (P = 0.493). These findings demonstrated that the CA/C ratio can exhibit adaptive adjustments. The observed nature and amount of the oculomotor modification failed to compensate for the stereoscopic constraint.

  14. Single-channel stereoscopic ophthalmology microscope based on TRD

    NASA Astrophysics Data System (ADS)

    Radfar, Edalat; Park, Jihoon; Lee, Sangyeob; Ha, Myungjin; Yu, Sungkon; Jang, Seulki; Jung, Byungjo

    2016-03-01

    A stereoscopic imaging modality was developed for the application of ophthalmology surgical microscopes. A previous study has already introduced a single-channel stereoscopic video imaging modality based on a transparent rotating deflector (SSVIM-TRD), in which two different view angles, image disparity, are generated by imaging through a transparent rotating deflector (TRD) mounted on a stepping motor and is placed in a lens system. In this case, the image disparity is a function of the refractive index and the rotation angle of TRD. Real-time single-channel stereoscopic ophthalmology microscope (SSOM) based on the TRD is improved by real-time controlling and programming, imaging speed, and illumination method. Image quality assessments were performed to investigate images quality and stability during the TRD operation. Results presented little significant difference in image quality in terms of stability of structural similarity (SSIM). A subjective analysis was performed with 15 blinded observers to evaluate the depth perception improvement and presented significant improvement in the depth perception capability. Along with all evaluation results, preliminary results of rabbit eye imaging presented that the SSOM could be utilized as an ophthalmic operating microscopes to overcome some of the limitations of conventional ones.

  15. Usage of stereoscopic visualization in the learning contents of rotational motion.

    PubMed

    Matsuura, Shu

    2013-01-01

    Rotational motion plays an essential role in physics even at an introductory level. In addition, the stereoscopic display of three-dimensional graphics includes is advantageous for the presentation of rotational motions, particularly for depth recognition. However, the immersive visualization of rotational motion has been known to lead to dizziness and even nausea for some viewers. Therefore, the purpose of this study is to examine the onset of nausea and visual fatigue when learning rotational motion through the use of a stereoscopic display. The findings show that an instruction method with intermittent exposure of the stereoscopic display and a simplification of its visual components reduced the onset of nausea and visual fatigue for the viewers, which maintained the overall effect of instantaneous spatial recognition.

  16. Genetics Home Reference: factor VII deficiency

    MedlinePlus

    ... Facebook Twitter Home Health Conditions Factor VII deficiency Factor VII deficiency Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Factor VII deficiency is a rare bleeding disorder that varies ...

  17. Design of multi-view stereoscopic HD video transmission system based on MPEG-21 digital item adaptation

    NASA Astrophysics Data System (ADS)

    Lee, Seokhee; Lee, Kiyoung; Kim, Man Bae; Kim, JongWon

    2005-11-01

    In this paper, we propose a design of multi-view stereoscopic HD video transmission system based on MPEG-21 Digital Item Adaptation (DIA). It focuses on the compatibility and scalability to meet various user preferences and terminal capabilities. There exist a large variety of multi-view 3D HD video types according to the methods for acquisition, display, and processing. By following the MPEG-21 DIA framework, the multi-view stereoscopic HD video is adapted according to user feedback. A user can be served multi-view stereoscopic video which corresponds with his or her preferences and terminal capabilities. In our preliminary prototype, we verify that the proposed design can support two deferent types of display device (stereoscopic and auto-stereoscopic) and switching viewpoints between two available viewpoints.

  18. Viewpoint Dependent Imaging: An Interactive Stereoscopic Display

    NASA Astrophysics Data System (ADS)

    Fisher, Scott

    1983-04-01

    Design and implementation of a viewpoint Dependent imaging system is described. The resultant display is an interactive, lifesize, stereoscopic image. that becomes a window into a three dimensional visual environment. As the user physically changes his viewpoint of the represented data in relation to the display surface, the image is continuously updated. The changing viewpoints are retrieved from a comprehensive, stereoscopic image array stored on computer controlled, optical videodisc and fluidly presented. in coordination with the viewer's, movements as detected by a body-tracking device. This imaging system is an attempt to more closely represent an observers interactive perceptual experience of the visual world by presenting sensory information cues not offered by traditional media technologies: binocular parallax, motion parallax, and motion perspective. Unlike holographic imaging, this display requires, relatively low bandwidth.

  19. Methodology for stereoscopic motion-picture quality assessment

    NASA Astrophysics Data System (ADS)

    Voronov, Alexander; Vatolin, Dmitriy; Sumin, Denis; Napadovsky, Vyacheslav; Borisov, Alexey

    2013-03-01

    Creating and processing stereoscopic video imposes additional quality requirements related to view synchronization. In this work we propose a set of algorithms for detecting typical stereoscopic-video problems, which appear owing to imprecise setup of capture equipment or incorrect postprocessing. We developed a methodology for analyzing the quality of S3D motion pictures and for revealing their most problematic scenes. We then processed 10 modern stereo films, including Avatar, Resident Evil: Afterlife and Hugo, and analyzed changes in S3D-film quality over the years. This work presents real examples of common artifacts (color and sharpness mismatch, vertical disparity and excessive horizontal disparity) in the motion pictures we processed, as well as possible solutions for each problem. Our results enable improved quality assessment during the filming and postproduction stages.

  20. Recent developments in stereoscopic and holographic 3D display technologies

    NASA Astrophysics Data System (ADS)

    Sarma, Kalluri

    2014-06-01

    Currently, there is increasing interest in the development of high performance 3D display technologies to support a variety of applications including medical imaging, scientific visualization, gaming, education, entertainment, air traffic control and remote operations in 3D environments. In this paper we will review the attributes of the various 3D display technologies including stereoscopic and holographic 3D, human factors issues of stereoscopic 3D, the challenges in realizing Holographic 3D displays and the recent progress in these technologies.

  1. Experiments on shape perception in stereoscopic displays

    NASA Astrophysics Data System (ADS)

    Leroy, Laure; Fuchs, Philippe; Paljic, Alexis; Moreau, Guillaume

    2009-02-01

    Stereoscopic displays are increasingly used for computer-aided design. The aim is to make virtual prototypes to avoid building real ones, so that time, money and raw materials are saved. But do we really know whether virtual displays render the objects in a realistic way to potential users? In this study, we have performed several experiments in which we compare two virtual shapes to their equivalent in the real world, each of these aiming at a specific issue by a comparison: First, we performed some perception tests to evaluate the importance of head tracking to evaluate if it is better to concentrate our efforts on stereoscopic vision; Second, we have studied the effects of interpupillary distance; Third, we studied the effects of the position of the main object in comparison with the screen. Two different tests are used, the first one using a well-known shape (a sphere) and the second one using an irregular shape but with almost the same colour and dimension. These two tests allow us to determine if symmetry is important in their perception. We show that head tracking has a more important effect on shape perception than stereoscopic vision, especially on depth perception because the subject is able to move around the scene. The study also shows that an object between the subject and the screen is perceived better than an object which is on the screen, even if the latter is better for the eye strain.

  2. Digital stereoscopic convergence where video games and movies for the home user meet

    NASA Astrophysics Data System (ADS)

    Schur, Ethan

    2009-02-01

    Today there is a proliferation of stereoscopic 3D display devices, 3D content, and 3D enabled video games. As we in the S-3D community bring stereoscopic 3D to the home user we have a real opportunity of using stereoscopic 3D to bridge the gap between exciting immersive games and home movies. But to do this, we cannot limit ourselves to current conceptions of gaming and movies. We need, for example, to imagine a movie that is fully rendered using avatars in a stereoscopic game environment. Or perhaps to imagine a pervasive drama where viewers can play too and become an essential part of the drama - whether at home or on the go on a mobile platform. Stereoscopic 3D is the "glue" that will bind these video and movie concepts together. As users feel more immersed, the lines between current media will blur. This means that we have the opportunity to shape the way that we, as humans, view and interact with each other, our surroundings and our most fundamental art forms. The goal of this paper is to stimulate conversation and further development on expanding the current gaming and home theatre infrastructures to support greatly-enhanced experiential entertainment.

  3. Increased volume of distribution for recombinant activated factor VII and longer plasma-derived factor VII half-life may explain their long lasting prophylactic effect.

    PubMed

    Mathijssen, Natascha C J; Masereeuw, Rosalinde; Holme, Pal Andre; van Kraaij, Marian G J; Laros-van Gorkom, Britta A P; Peyvandi, Flora; van Heerde, Waander L

    2013-08-01

    Prophylaxis with plasma-derived or recombinant activated factor VII is beneficial in severe factor VII deficiency. To understand why prophylactic treatment with both products is efficacious, we conducted a pharmacokinetic study. Ten factor VII deficient patients were treated with either recombinant activated (20 μg/kg) or plasma-derived (25 IU/kg) factor VII in a cross-over design. Pharmacokinetic parameters were analyzed through activated factor VII activity, factor VII clotting activity, and factor VII antigen levels on depicted time points. Factor VII activity half-lifes, determined by non-compartmental and one-compartmental analysis (results in brackets), were shorter for recombinant activated (1.4h; 0.7h) than for plasma-derived factor VII (6.8h; 3.2h); both recombinant activated (5.1h; 2.1h and plasma-derived factor VII (5.8h; 3.2h) resulted in longer half-lives of factor VII antigen. Activated factor VII half-lives (based on activated factor VII activity levels) were significantly higher compared to factor VII clotting activity (1.6h; 0.9h). Volumes of distribution were significantly higher for activated factor VII (236 ml/kg; 175 ml/kg, measured by activated factor VII) as compared to plasma-derived factor VII (206 ml/kg; 64 ml/kg, measured by factor FVII activity), suggesting a plasma- and extracellular fluid distribution for recombinant activated factor VII. Recombinant activated factor VII showed significantly shorter half-lifes than plasma-derived factor VII. Volumes of distribution were significantly higher for treatment with recombinant activated factor VII. The longer half-life for plasma-derived factor VII, compared to recombinant activated factor VII, and the increased volume of distribution for recombinant activated factor VII, compared to plasma-derived factor VII may further elucidate the beneficial effect of prophylactic treatment of both products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Depth Perception and the History of Three-Dimensional Art: Who Produced the First Stereoscopic Images?

    PubMed Central

    2017-01-01

    The history of the expression of three-dimensional structure in art can be traced from the use of occlusion in Palaeolithic cave paintings, through the use of shadow in classical art, to the development of perspective during the Renaissance. However, the history of the use of stereoscopic techniques is controversial. Although the first undisputed stereoscopic images were presented by Wheatstone in 1838, it has been claimed that two sketches by Jacopo Chimenti da Empoli (c. 1600) can be to be fused to yield an impression of stereoscopic depth, while others suggest that Leonardo da Vinci’s Mona Lisa is the world’s first stereogram. Here, we report the first quantitative study of perceived depth in these works, in addition to more recent works by Salvador Dalí. To control for the contribution of monocular depth cues, ratings of the magnitude and coherence of depth were recorded for both stereoscopic and pseudoscopic presentations, with a genuine contribution of stereoscopic cues revealed by a difference between these scores. Although effects were clear for Wheatstone and Dalí’s images, no such effects could be found for works produced earlier. As such, we have no evidence to reject the conventional view that the first producer of stereoscopic imagery was Sir Charles Wheatstone. PMID:28203349

  5. Depth Perception and the History of Three-Dimensional Art: Who Produced the First Stereoscopic Images?

    PubMed

    Brooks, Kevin R

    2017-01-01

    The history of the expression of three-dimensional structure in art can be traced from the use of occlusion in Palaeolithic cave paintings, through the use of shadow in classical art, to the development of perspective during the Renaissance. However, the history of the use of stereoscopic techniques is controversial. Although the first undisputed stereoscopic images were presented by Wheatstone in 1838, it has been claimed that two sketches by Jacopo Chimenti da Empoli (c. 1600) can be to be fused to yield an impression of stereoscopic depth, while others suggest that Leonardo da Vinci's Mona Lisa is the world's first stereogram. Here, we report the first quantitative study of perceived depth in these works, in addition to more recent works by Salvador Dalí. To control for the contribution of monocular depth cues, ratings of the magnitude and coherence of depth were recorded for both stereoscopic and pseudoscopic presentations, with a genuine contribution of stereoscopic cues revealed by a difference between these scores. Although effects were clear for Wheatstone and Dalí's images, no such effects could be found for works produced earlier. As such, we have no evidence to reject the conventional view that the first producer of stereoscopic imagery was Sir Charles Wheatstone.

  6. Intelsat VII program and the future

    NASA Astrophysics Data System (ADS)

    Madon, P. J.; Sachdev, D. K.

    The evolution of the Intelsat VII spacecraft is discussed. The role of competitive procurement process in this evolution is addressed, and the overall system-level features of the spacecraft are reviewed. The time frame for the five Intelsat VII missions is summarized, and follow-up projects to Intelsat VII are discussed.

  7. High-speed switchable lens enables the development of a volumetric stereoscopic display

    PubMed Central

    Love, Gordon D.; Hoffman, David M.; Hands, Philip J.W.; Gao, James; Kirby, Andrew K.; Banks, Martin S.

    2011-01-01

    Stereoscopic displays present different images to the two eyes and thereby create a compelling three-dimensional (3D) sensation. They are being developed for numerous applications including cinema, television, virtual prototyping, and medical imaging. However, stereoscopic displays cause perceptual distortions, performance decrements, and visual fatigue. These problems occur because some of the presented depth cues (i.e., perspective and binocular disparity) specify the intended 3D scene while focus cues (blur and accommodation) specify the fixed distance of the display itself. We have developed a stereoscopic display that circumvents these problems. It consists of a fast switchable lens synchronized to the display such that focus cues are nearly correct. The system has great potential for both basic vision research and display applications. PMID:19724571

  8. The Role of Amodal Surface Completion in Stereoscopic Transparency

    PubMed Central

    Anderson, Barton L.; Schmid, Alexandra C.

    2012-01-01

    Previous work has shown that the visual system can decompose stereoscopic textures into percepts of inhomogeneous transparency. We investigate whether this form of layered image decomposition is shaped by constraints on amodal surface completion. We report a series of experiments that demonstrate that stereoscopic depth differences are easier to discriminate when the stereo images generate a coherent percept of surface color, than when images require amodally integrating a series of color changes into a coherent surface. Our results provide further evidence for the intimate link between the segmentation processes that occur in conditions of transparency and occlusion, and the interpolation processes involved in the formation of amodally completed surfaces. PMID:23060829

  9. Integrating multi-view transmission system into MPEG-21 stereoscopic and multi-view DIA (digital item adaptation)

    NASA Astrophysics Data System (ADS)

    Lee, Seungwon; Park, Ilkwon; Kim, Manbae; Byun, Hyeran

    2006-10-01

    As digital broadcasting technologies have been rapidly progressed, users' expectations for realistic and interactive broadcasting services also have been increased. As one of such services, 3D multi-view broadcasting has received much attention recently. In general, all the view sequences acquired at the server are transmitted to the client. Then, the user can select a part of views or all the views according to display capabilities. However, this kind of system requires high processing power of the server as well as the client, thus posing a difficulty in practical applications. To overcome this problem, a relatively simple method is to transmit only two view-sequences requested by the client in order to deliver a stereoscopic video. In this system, effective communication between the server and the client is one of important aspects. In this paper, we propose an efficient multi-view system that transmits two view-sequences and their depth maps according to user's request. The view selection process is integrated into MPEG-21 DIA (Digital Item Adaptation) so that our system is compatible to MPEG-21 multimedia framework. DIA is generally composed of resource adaptation and descriptor adaptation. It is one of merits that SVA (stereoscopic video adaptation) descriptors defined in DIA standard are used to deliver users' preferences and device capabilities. Furthermore, multi-view descriptions related to multi-view camera and system are newly introduced. The syntax of the descriptions and their elements is represented in XML (eXtensible Markup Language) schema. If the client requests an adapted descriptor (e.g., view numbers) to the server, then the server sends its associated view sequences. Finally, we present a method which can reduce user's visual discomfort that might occur while viewing stereoscopic video. This phenomenon happens when view changes as well as when a stereoscopic image produces excessive disparity caused by a large baseline between two cameras. To

  10. The compressed average image intensity metric for stereoscopic video quality assessment

    NASA Astrophysics Data System (ADS)

    Wilczewski, Grzegorz

    2016-09-01

    The following article depicts insights towards design, creation and testing of a genuine metric designed for a 3DTV video quality evaluation. The Compressed Average Image Intensity (CAII) mechanism is based upon stereoscopic video content analysis, setting its core feature and functionality to serve as a versatile tool for an effective 3DTV service quality assessment. Being an objective type of quality metric it may be utilized as a reliable source of information about the actual performance of a given 3DTV system, under strict providers evaluation. Concerning testing and the overall performance analysis of the CAII metric, the following paper presents comprehensive study of results gathered across several testing routines among selected set of samples of stereoscopic video content. As a result, the designed method for stereoscopic video quality evaluation is investigated across the range of synthetic visual impairments injected into the original video stream.

  11. Clinically Normal Stereopsis Does Not Ensure Performance Benefit from Stereoscopic 3D Depth Cues

    DTIC Science & Technology

    2014-10-28

    Stereopsis, Binocular Vision, Optometry , Depth Perception, 3D vision, 3D human factors, Stereoscopic displays, S3D, Virtual environment 16...Binocular Vision, Optometry , Depth Perception, 3D vision, 3D human factors, Stereoscopic displays, S3D, Virtual environment 1 Distribution A: Approved

  12. A 3-D mixed-reality system for stereoscopic visualization of medical dataset.

    PubMed

    Ferrari, Vincenzo; Megali, Giuseppe; Troia, Elena; Pietrabissa, Andrea; Mosca, Franco

    2009-11-01

    We developed a simple, light, and cheap 3-D visualization device based on mixed reality that can be used by physicians to see preoperative radiological exams in a natural way. The system allows the user to see stereoscopic "augmented images," which are created by mixing 3-D virtual models of anatomies obtained by processing preoperative volumetric radiological images (computed tomography or MRI) with real patient live images, grabbed by means of cameras. The interface of the system consists of a head-mounted display equipped with two high-definition cameras. Cameras are mounted in correspondence of the user's eyes and allow one to grab live images of the patient with the same point of view of the user. The system does not use any external tracker to detect movements of the user or the patient. The movements of the user's head and the alignment of virtual patient with the real one are done using machine vision methods applied on pairs of live images. Experimental results, concerning frame rate and alignment precision between virtual and real patient, demonstrate that machine vision methods used for localization are appropriate for the specific application and that systems based on stereoscopic mixed reality are feasible and can be proficiently adopted in clinical practice.

  13. Stereoscopic wide field of view imaging system

    NASA Technical Reports Server (NTRS)

    Prechtl, Eric F. (Inventor); Sedwick, Raymond J. (Inventor); Jonas, Eric M. (Inventor)

    2011-01-01

    A stereoscopic imaging system incorporates a plurality of imaging devices or cameras to generate a high resolution, wide field of view image database from which images can be combined in real time to provide wide field of view or panoramic or omni-directional still or video images.

  14. Acquisition of Stereoscopic Particle Image Velocimetry System for Investigation of Unsteady Flows

    DTIC Science & Technology

    2016-04-30

    SECURITY CLASSIFICATION OF: The objective of the project titled “Acquisition of Stereoscopic Particle Image Velocimetry (S-PIV) System for...Distribution Unlimited UU UU UU UU 30-04-2016 1-Feb-2015 31-Jan-2016 Final Report: Acquisition of Stereoscopic Particle Image Velocimetry System For...ADDRESS (ES) U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 Particle Image Velocimetry REPORT DOCUMENTATION PAGE 11

  15. Automated volumetric evaluation of stereoscopic disc photography

    PubMed Central

    Xu, Juan; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Craig, Jamie E; Mackey, David A; Hewitt, Alex W; Schuman, Joel S

    2010-01-01

    PURPOSE: To develop a fully automated algorithm (AP) to perform a volumetric measure of the optic disc using conventional stereoscopic optic nerve head (ONH) photographs, and to compare algorithm-produced parameters with manual photogrammetry (MP), scanning laser ophthalmoscope (SLO) and optical coherence tomography (OCT) measurements. METHODS: One hundred twenty-two stereoscopic optic disc photographs (61 subjects) were analyzed. Disc area, rim area, cup area, cup/disc area ratio, vertical cup/disc ratio, rim volume and cup volume were automatically computed by the algorithm. Latent variable measurement error models were used to assess measurement reproducibility for the four techniques. RESULTS: AP had better reproducibility for disc area and cup volume and worse reproducibility for cup/disc area ratio and vertical cup/disc ratio, when the measurements were compared to the MP, SLO and OCT methods. CONCLUSION: AP provides a useful technique for an objective quantitative assessment of 3D ONH structures. PMID:20588996

  16. Monoscopic versus stereoscopic photography in screening for clinically significant macular edema.

    PubMed

    Welty, Christopher J; Agarwal, Anita; Merin, Lawrence M; Chomsky, Amy

    2006-01-01

    The purpose of the study was to determine whether monoscopic photography could serve as an accurate tool when used to screen for clinically significant macular edema. In a masked randomized fashion, two readers evaluated monoscopic and stereoscopic retinal photographs of 100 eyes. The photographs were evaluated first individually for probable clinically significant macular edema based on the Early Treatment Diabetic Retinopathy Study criteria and then as stereoscopic pairs. Graders were evaluated for sensitivity and specificity individually and in combination. Individually, reader one had a sensitivity of 0.93 and a specificity of 0.77, and reader two had a sensitivity of 0.88 and a specificity of 0.94. In combination, the readers had a sensitivity of 0.91 and a specificity of 0.86. They correlated on 0.76 of the stereoscopic readings and 0.92 of the monoscopic readings. These results indicate that the use of monoscopic retinal photography may be an accurate screening tool for clinically significant macular edema.

  17. Evaluating stereoscopic displays: both efficiency measures and perceived workload sensitive to manipulations in binocular disparity

    NASA Astrophysics Data System (ADS)

    van Beurden, Maurice H. P. H.; Ijsselsteijn, Wijnand A.; de Kort, Yvonne A. W.

    2011-03-01

    Stereoscopic displays are known to offer a number of key advantages in visualizing complex 3D structures or datasets. The large majority of studies that focus on evaluating stereoscopic displays for professional applications use completion time and/or the percentage of correct answers to measure potential performance advantages. However, completion time and accuracy may not fully reflect all the benefits of stereoscopic displays. In this paper, we argue that perceived workload is an additional valuable indicator reflecting the extent to which users can benefit from using stereoscopic displays. We performed an experiment in which participants were asked to perform a visual path-tracing task within a convoluted 3D wireframe structure, varying in level of complexity of the visualised structure and level of disparity of the visualisation. The results showed that an optimal performance (completion time, accuracy and workload), depend both on task difficulty and disparity level. Stereoscopic disparity revealed a faster and more accurate task performance, whereas we observed a trend that performance on difficult tasks stands to benefit more from higher levels of disparity than performance on easy tasks. Perceived workload (as measured using the NASA-TLX) showed a similar response pattern, providing evidence that perceived workload is sensitive to variations in disparity as well as task difficulty. This suggests that perceived workload could be a useful concept, in addition to standard performance indicators, in characterising and measuring human performance advantages when using stereoscopic displays.

  18. Improving Bilingual Program Management. A Handbook for Title VII Directors.

    ERIC Educational Resources Information Center

    DeGeorge, George P., Ed.

    Filled with practical advice and workable techniques and strategies to help bilingual program directors deal with the problems they face, this handbook brings together ideas and suggestions from Title VII program directors, state coordinators, and superintendents with experience in bilingual programs. The handbook, written in question and answer…

  19. SEISVIZ3D: Stereoscopic system for the representation of seismic data - Interpretation and Immersion

    NASA Astrophysics Data System (ADS)

    von Hartmann, Hartwig; Rilling, Stefan; Bogen, Manfred; Thomas, Rüdiger

    2015-04-01

    The seismic method is a valuable tool for getting 3D-images from the subsurface. Seismic data acquisition today is not only a topic for oil and gas exploration but is used also for geothermal exploration, inspections of nuclear waste sites and for scientific investigations. The system presented in this contribution may also have an impact on the visualization of 3D-data of other geophysical methods. 3D-seismic data can be displayed in different ways to give a spatial impression of the subsurface.They are a combination of individual vertical cuts, possibly linked to a cubical portion of the data volume, and the stereoscopic view of the seismic data. By these methods, the spatial perception for the structures and thus of the processes in the subsurface should be increased. Stereoscopic techniques are e. g. implemented in the CAVE and the WALL, both of which require a lot of space and high technical effort. The aim of the interpretation system shown here is stereoscopic visualization of seismic data at the workplace, i.e. at the personal workstation and monitor. The system was developed with following criteria in mind: • Fast rendering of large amounts of data so that a continuous view of the data when changing the viewing angle and the data section is possible, • defining areas in stereoscopic view to translate the spatial impression directly into an interpretation, • the development of an appropriate user interface, including head-tracking, for handling the increased degrees of freedom, • the possibility of collaboration, i.e. teamwork and idea exchange with the simultaneous viewing of a scene at remote locations. The possibilities offered by the use of a stereoscopic system do not replace a conventional interpretation workflow. Rather they have to be implemented into it as an additional step. The amplitude distribution of the seismic data is a challenge for the stereoscopic display because the opacity level and the scaling and selection of the data have to

  20. The Effect of Two-dimensional and Stereoscopic Presentation on Middle School Students' Performance of Spatial Cognition Tasks

    NASA Astrophysics Data System (ADS)

    Price, Aaron; Lee, Hee-Sun

    2010-02-01

    We investigated whether and how student performance on three types of spatial cognition tasks differs when worked with two-dimensional or stereoscopic representations. We recruited nineteen middle school students visiting a planetarium in a large Midwestern American city and analyzed their performance on a series of spatial cognition tasks in terms of response accuracy and task completion time. Results show that response accuracy did not differ between the two types of representations while task completion time was significantly greater with the stereoscopic representations. The completion time increased as the number of mental manipulations of 3D objects increased in the tasks. Post-interviews provide evidence that some students continued to think of stereoscopic representations as two-dimensional. Based on cognitive load and cue theories, we interpret that, in the absence of pictorial depth cues, students may need more time to be familiar with stereoscopic representations for optimal performance. In light of these results, we discuss potential uses of stereoscopic representations for science learning.

  1. Toward a 3D video format for auto-stereoscopic displays

    NASA Astrophysics Data System (ADS)

    Vetro, Anthony; Yea, Sehoon; Smolic, Aljoscha

    2008-08-01

    There has been increased momentum recently in the production of 3D content for cinema applications; for the most part, this has been limited to stereo content. There are also a variety of display technologies on the market that support 3DTV, each offering a different viewing experience and having different input requirements. More specifically, stereoscopic displays support stereo content and require glasses, while auto-stereoscopic displays avoid the need for glasses by rendering view-dependent stereo pairs for a multitude of viewing angles. To realize high quality auto-stereoscopic displays, multiple views of the video must either be provided as input to the display, or these views must be created locally at the display. The former approach has difficulties in that the production environment is typically limited to stereo, and transmission bandwidth for a large number of views is not likely to be available. This paper discusses an emerging 3D data format that enables the latter approach to be realized. A new framework for efficiently representing a 3D scene and enabling the reconstruction of an arbitrarily large number of views prior to rendering is introduced. Several design challenges are also highlighted through experimental results.

  2. Balance and coordination after viewing stereoscopic 3D television

    PubMed Central

    Read, Jenny C. A.; Simonotto, Jennifer; Bohr, Iwo; Godfrey, Alan; Galna, Brook; Rochester, Lynn; Smulders, Tom V.

    2015-01-01

    Manufacturers and the media have raised the possibility that viewing stereoscopic 3D television (S3D TV) may cause temporary disruption to balance and visuomotor coordination. We looked for evidence of such effects in a laboratory-based study. Four hundred and thirty-three people aged 4–82 years old carried out tests of balance and coordination before and after viewing an 80 min movie in either conventional 2D or stereoscopic 3D, while wearing two triaxial accelerometers. Accelerometry produced little evidence of any change in body motion associated with S3D TV. We found no evidence that viewing the movie in S3D causes a detectable impairment in balance or in visuomotor coordination. PMID:26587261

  3. Newly diagnosed congenital factor VII deficiency and utilization of recombinant activated factor VII (NovoSeven(®)).

    PubMed

    Bartosh, Nicole S; Tomlin, Tara; Cable, Christian; Halka, Kathleen

    2013-01-01

    This case report presents a newly diagnosed congenital factor VII deficiency treated with recombinant activated factor VII (rFVIIa). Congenital factor VII deficiency is a rare autosomal-recessive bleeding disorder that occurs in fewer than 1/500,000 persons. Its presentation can vary from epistaxis to hemarthroses and severe central nervous system bleeding, and correlates poorly with factor VII levels. Our patient had not had a significant hemostatic challenge prior to his presentation and therefore never had any symptomatology suggestive of this disease. He was treated with rFVIIa, and was able to undergo repair of his fractures without bleeding. A 19-year-old African-American male presented to the emergency room after an altercation that resulted in significant trauma. He sustained bilateral mandibular angle fractures and orbital floor fractures, requiring urgent surgical correction. On initial evaluation, he was noted to have a prolonged prothrombin time of 40.1 seconds, with an International Normalized Ratio of 4.0, a normal activated partial thromboplastin time of 29.9 seconds, and a platelet count of 241. After receiving vitamin K and fresh frozen plasma, he was taken to the operating room for a temporary rigid maxillomandibular fixation. A 1:1 mixing study with normal plasma corrected the prothrombin time (decreasing from 40.7 to 14.7 seconds) and a factor VII assay revealed 5% of the normal factor VII level. The patient was diagnosed with congenital factor VII deficiency. Due to his coagulopathy and the extensive surgical correction needed, rFVIIa was administered and surgery was accomplished without hemorrhagic sequelae. This case report and review describes a rare congenital disease, the history of rFVIIa use, and its mechanism. rFVIIA use in our patient provided a treatment option that allowed the necessary surgical correction, but further prospective studies on dose optimization would ensure adequate dosing with minimal risk of severe side effects.

  4. YouDash3D: exploring stereoscopic 3D gaming for 3D movie theaters

    NASA Astrophysics Data System (ADS)

    Schild, Jonas; Seele, Sven; Masuch, Maic

    2012-03-01

    Along with the success of the digitally revived stereoscopic cinema, events beyond 3D movies become attractive for movie theater operators, i.e. interactive 3D games. In this paper, we present a case that explores possible challenges and solutions for interactive 3D games to be played by a movie theater audience. We analyze the setting and showcase current issues related to lighting and interaction. Our second focus is to provide gameplay mechanics that make special use of stereoscopy, especially depth-based game design. Based on these results, we present YouDash3D, a game prototype that explores public stereoscopic gameplay in a reduced kiosk setup. It features live 3D HD video stream of a professional stereo camera rig rendered in a real-time game scene. We use the effect to place the stereoscopic effigies of players into the digital game. The game showcases how stereoscopic vision can provide for a novel depth-based game mechanic. Projected trigger zones and distributed clusters of the audience video allow for easy adaptation to larger audiences and 3D movie theater gaming.

  5. Subjective experiences of watching stereoscopic Avatar and U2 3D in a cinema

    NASA Astrophysics Data System (ADS)

    Pölönen, Monika; Salmimaa, Marja; Takatalo, Jari; Häkkinen, Jukka

    2012-01-01

    A stereoscopic 3-D version of the film Avatar was shown to 85 people who subsequently answered questions related to sickness, visual strain, stereoscopic image quality, and sense of presence. Viewing Avatar for 165 min induced some symptoms of visual strain and sickness, but the symptom levels remained low. A comparison between Avatar and previously published results for the film U2 3D showed that sickness and visual strain levels were similar despite the films' runtimes. The genre of the film had a significant effect on the viewers' opinions and sense of presence. Avatar, which has been described as a combination of action, adventure, and sci-fi genres, was experienced as more immersive and engaging than the music documentary U2 3D. However, participants in both studies were immersed, focused, and absorbed in watching the stereoscopic 3-D (S3-D) film and were pleased with the film environments. The results also showed that previous stereoscopic 3-D experience significantly reduced the amount of reported eye strain and complaints about the weight of the viewing glasses.

  6. Parallax scanning methods for stereoscopic three-dimensional imaging

    NASA Astrophysics Data System (ADS)

    Mayhew, Christopher A.; Mayhew, Craig M.

    2012-03-01

    Under certain circumstances, conventional stereoscopic imagery is subject to being misinterpreted. Stereo perception created from two static horizontally separated views can create a "cut out" 2D appearance for objects at various planes of depth. The subject volume looks three-dimensional, but the objects themselves appear flat. This is especially true if the images are captured using small disparities. One potential explanation for this effect is that, although three-dimensional perception comes primarily from binocular vision, a human's gaze (the direction and orientation of a person's eyes with respect to their environment) and head motion also contribute additional sub-process information. The absence of this information may be the reason that certain stereoscopic imagery appears "odd" and unrealistic. Another contributing factor may be the absence of vertical disparity information in a traditional stereoscopy display. Recently, Parallax Scanning technologies have been introduced, which provide (1) a scanning methodology, (2) incorporate vertical disparity, and (3) produce stereo images with substantially smaller disparities than the human interocular distances.1 To test whether these three features would improve the realism and reduce the cardboard cutout effect of stereo images, we have applied Parallax Scanning (PS) technologies to commercial stereoscopic digital cinema productions and have tested the results with a panel of stereo experts. These informal experiments show that the addition of PS information into the left and right image capture improves the overall perception of three-dimensionality for most viewers. Parallax scanning significantly increases the set of tools available for 3D storytelling while at the same time presenting imagery that is easy and pleasant to view.

  7. Research and Construction Lunar Stereoscopic Visualization System Based on Chang'E Data

    NASA Astrophysics Data System (ADS)

    Gao, Xingye; Zeng, Xingguo; Zhang, Guihua; Zuo, Wei; Li, ChunLai

    2017-04-01

    With lunar exploration activities carried by Chang'E-1, Chang'E-2 and Chang'E-3 lunar probe, a large amount of lunar data has been obtained, including topographical and image data covering the whole moon, as well as the panoramic image data of the spot close to the landing point of Chang'E-3. In this paper, we constructed immersive virtual moon system based on acquired lunar exploration data by using advanced stereoscopic visualization technology, which will help scholars to carry out research on lunar topography, assist the further exploration of lunar science, and implement the facilitation of lunar science outreach to the public. In this paper, we focus on the building of lunar stereoscopic visualization system with the combination of software and hardware by using binocular stereoscopic display technology, real-time rendering algorithm for massive terrain data, and building virtual scene technology based on panorama, to achieve an immersive virtual tour of the whole moon and local moonscape of Chang'E-3 landing point.

  8. Use of camera drive in stereoscopic display of learning contents of introductory physics

    NASA Astrophysics Data System (ADS)

    Matsuura, Shu

    2011-03-01

    Simple 3D physics simulations with stereoscopic display were created for a part of introductory physics e-Learning. First, cameras to see the 3D world can be made controllable by the user. This enabled to observe the system and motions of objects from any position in the 3D world. Second, cameras were made attachable to one of the moving object in the simulation so as to observe the relative motion of other objects. By this option, it was found that users perceive the velocity and acceleration more sensibly on stereoscopic display than on non-stereoscopic 3D display. Simulations were made using Adobe Flash ActionScript, and Papervison 3D library was used to render the 3D models in the flash web pages. To display the stereogram, two viewports from virtual cameras were displayed in parallel in the same web page. For observation of stereogram, the images of two viewports were superimposed by using 3D stereogram projection box (T&TS CO., LTD.), and projected on an 80-inch screen. The virtual cameras were controlled by keyboard and also by Nintendo Wii remote controller buttons. In conclusion, stereoscopic display offers learners more opportunities to play with the simulated models, and to perceive the characteristics of motion better.

  9. Stereoscopic vascular models of the head and neck: A computed tomography angiography visualization.

    PubMed

    Cui, Dongmei; Lynch, James C; Smith, Andrew D; Wilson, Timothy D; Lehman, Michael N

    2016-01-01

    Computer-assisted 3D models are used in some medical and allied health science schools; however, they are often limited to online use and 2D flat screen-based imaging. Few schools take advantage of 3D stereoscopic learning tools in anatomy education and clinically relevant anatomical variations when teaching anatomy. A new approach to teaching anatomy includes use of computed tomography angiography (CTA) images of the head and neck to create clinically relevant 3D stereoscopic virtual models. These high resolution images of the arteries can be used in unique and innovative ways to create 3D virtual models of the vasculature as a tool for teaching anatomy. Blood vessel 3D models are presented stereoscopically in a virtual reality environment, can be rotated 360° in all axes, and magnified according to need. In addition, flexible views of internal structures are possible. Images are displayed in a stereoscopic mode, and students view images in a small theater-like classroom while wearing polarized 3D glasses. Reconstructed 3D models enable students to visualize vascular structures with clinically relevant anatomical variations in the head and neck and appreciate spatial relationships among the blood vessels, the skull and the skin. © 2015 American Association of Anatomists.

  10. Perceptual full-reference quality assessment of stereoscopic images by considering binocular visual characteristics.

    PubMed

    Shao, Feng; Lin, Weisi; Gu, Shanbo; Jiang, Gangyi; Srikanthan, Thambipillai

    2013-05-01

    Perceptual quality assessment is a challenging issue in 3D signal processing research. It is important to study 3D signal directly instead of studying simple extension of the 2D metrics directly to the 3D case as in some previous studies. In this paper, we propose a new perceptual full-reference quality assessment metric of stereoscopic images by considering the binocular visual characteristics. The major technical contribution of this paper is that the binocular perception and combination properties are considered in quality assessment. To be more specific, we first perform left-right consistency checks and compare matching error between the corresponding pixels in binocular disparity calculation, and classify the stereoscopic images into non-corresponding, binocular fusion, and binocular suppression regions. Also, local phase and local amplitude maps are extracted from the original and distorted stereoscopic images as features in quality assessment. Then, each region is evaluated independently by considering its binocular perception property, and all evaluation results are integrated into an overall score. Besides, a binocular just noticeable difference model is used to reflect the visual sensitivity for the binocular fusion and suppression regions. Experimental results show that compared with the relevant existing metrics, the proposed metric can achieve higher consistency with subjective assessment of stereoscopic images.

  11. Measuring sensitivity to viewpoint change with and without stereoscopic cues.

    PubMed

    Bell, Jason; Dickinson, Edwin; Badcock, David R; Kingdom, Frederick A A

    2013-12-04

    The speed and accuracy of object recognition is compromised by a change in viewpoint; demonstrating that human observers are sensitive to this transformation. Here we discuss a novel method for simulating the appearance of an object that has undergone a rotation-in-depth, and include an exposition of the differences between perspective and orthographic projections. Next we describe a method by which human sensitivity to rotation-in-depth can be measured. Finally we discuss an apparatus for creating a vivid percept of a 3-dimensional rotation-in-depth; the Wheatstone Eight Mirror Stereoscope. By doing so, we reveal a means by which to evaluate the role of stereoscopic cues in the discrimination of viewpoint rotated shapes and objects.

  12. 40 CFR Appendix Vii to Part 600 - [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 31 2013-07-01 2013-07-01 false [Reserved] VII Appendix VII to Part 600 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Appendix VII to Part 600 [Reserved] ...

  13. 40 CFR Appendix Vii to Part 600 - [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 31 2012-07-01 2012-07-01 false [Reserved] VII Appendix VII to Part 600 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Appendix VII to Part 600 [Reserved] ...

  14. 40 CFR Appendix Vii to Part 600 - [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 30 2014-07-01 2014-07-01 false [Reserved] VII Appendix VII to Part 600 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Appendix VII to Part 600 [Reserved] ...

  15. Newly diagnosed congenital factor VII deficiency and utilization of recombinant activated factor VII (NovoSeven®)

    PubMed Central

    Bartosh, Nicole S; Tomlin, Tara; Cable, Christian; Halka, Kathleen

    2013-01-01

    This case report presents a newly diagnosed congenital factor VII deficiency treated with recombinant activated factor VII (rFVIIa). Congenital factor VII deficiency is a rare autosomal-recessive bleeding disorder that occurs in fewer than 1/500,000 persons. Its presentation can vary from epistaxis to hemarthroses and severe central nervous system bleeding, and correlates poorly with factor VII levels. Our patient had not had a significant hemostatic challenge prior to his presentation and therefore never had any symptomatology suggestive of this disease. He was treated with rFVIIa, and was able to undergo repair of his fractures without bleeding. Case report A 19-year-old African-American male presented to the emergency room after an altercation that resulted in significant trauma. He sustained bilateral mandibular angle fractures and orbital floor fractures, requiring urgent surgical correction. On initial evaluation, he was noted to have a prolonged prothrombin time of 40.1 seconds, with an International Normalized Ratio of 4.0, a normal activated partial thromboplastin time of 29.9 seconds, and a platelet count of 241. After receiving vitamin K and fresh frozen plasma, he was taken to the operating room for a temporary rigid maxillomandibular fixation. A 1:1 mixing study with normal plasma corrected the prothrombin time (decreasing from 40.7 to 14.7 seconds) and a factor VII assay revealed 5% of the normal factor VII level. The patient was diagnosed with congenital factor VII deficiency. Due to his coagulopathy and the extensive surgical correction needed, rFVIIa was administered and surgery was accomplished without hemorrhagic sequelae. Conclusion This case report and review describes a rare congenital disease, the history of rFVIIa use, and its mechanism. rFVIIA use in our patient provided a treatment option that allowed the necessary surgical correction, but further prospective studies on dose optimization would ensure adequate dosing with minimal risk of

  16. Role of hepsin in factor VII activation in zebrafish.

    PubMed

    Khandekar, Gauri; Jagadeeswaran, Pudur

    2014-01-01

    Factor VII, the initiator of the extrinsic coagulation cascade, circulates in human plasma mainly in its zymogen form, factor VII and in small amounts in its activated form, factor VIIa. However, the mechanism of initial generation of factor VIIa is not known despite intensive research using currently available model systems. Earlier findings suggested serine proteases factor VII activating protease and hepsin play a role in activating factor VII, however, it has remained controversial. In this paper we estimated the levels of factor VIIa and factor VII for the first time in zebrafish adult population and also reevaluated the role of the above two serine proteases in activating factor VII in vivo using zebrafish as a model system. Knockdown of factor VII activating protease and hepsin was performed followed by assaying for their effect on factor VIIa concentration and extrinsic coagulation as measured by the kinetic prothrombin time. Factor VII activating protease knockdown showed no change in kinetic prothrombin time and no effect on factor VIIa levels while hepsin knockdown increased the kinetic prothrombin time and significantly reduced the factor VIIa plasma levels. Our results thus indicate that hepsin plays a physiologically important role in factor VII activation and hemostasis in zebrafish. © 2013.

  17. Designing stereoscopic information visualization for 3D-TV: What can we can learn from S3D gaming?

    NASA Astrophysics Data System (ADS)

    Schild, Jonas; Masuch, Maic

    2012-03-01

    This paper explores graphical design and spatial alignment of visual information and graphical elements into stereoscopically filmed content, e.g. captions, subtitles, and especially more complex elements in 3D-TV productions. The method used is a descriptive analysis of existing computer- and video games that have been adapted for stereoscopic display using semi-automatic rendering techniques (e.g. Nvidia 3D Vision) or games which have been specifically designed for stereoscopic vision. Digital games often feature compelling visual interfaces that combine high usability with creative visual design. We explore selected examples of game interfaces in stereoscopic vision regarding their stereoscopic characteristics, how they draw attention, how we judge effect and comfort and where the interfaces fail. As a result, we propose a list of five aspects which should be considered when designing stereoscopic visual information: explicit information, implicit information, spatial reference, drawing attention, and vertical alignment. We discuss possible consequences, opportunities and challenges for integrating visual information elements into 3D-TV content. This work shall further help to improve current editing systems and identifies a need for future editing systems for 3DTV, e.g., live editing and real-time alignment of visual information into 3D footage.

  18. Novel microscope-integrated stereoscopic heads-up display for intrasurgical optical coherence tomography

    PubMed Central

    Shen, Liangbo; Carrasco-Zevallos, Oscar; Keller, Brenton; Viehland, Christian; Waterman, Gar; Hahn, Paul S.; Kuo, Anthony N.; Toth, Cynthia A.; Izatt, Joseph A.

    2016-01-01

    Intra-operative optical coherence tomography (OCT) requires a display technology which allows surgeons to visualize OCT data without disrupting surgery. Previous research and commercial intrasurgical OCT systems have integrated heads-up display (HUD) systems into surgical microscopes to provide monoscopic viewing of OCT data through one microscope ocular. To take full advantage of our previously reported real-time volumetric microscope-integrated OCT (4D MIOCT) system, we describe a stereoscopic HUD which projects a stereo pair of OCT volume renderings into both oculars simultaneously. The stereoscopic HUD uses a novel optical design employing spatial multiplexing to project dual OCT volume renderings utilizing a single micro-display. The optical performance of the surgical microscope with the HUD was quantitatively characterized and the addition of the HUD was found not to substantially effect the resolution, field of view, or pincushion distortion of the operating microscope. In a pilot depth perception subject study, five ophthalmic surgeons completed a pre-set dexterity task with 50.0% (SD = 37.3%) higher success rate and in 35.0% (SD = 24.8%) less time on average with stereoscopic OCT vision compared to monoscopic OCT vision. Preliminary experience using the HUD in 40 vitreo-retinal human surgeries by five ophthalmic surgeons is reported, in which all surgeons reported that the HUD did not alter their normal view of surgery and that live surgical maneuvers were readily visible in displayed stereoscopic OCT volumes. PMID:27231616

  19. Pathogenesis of lumbar spine disease in mucopolysaccharidosis VII

    PubMed Central

    Smith, Lachlan J; Baldo, Guilherme; Wu, Susan; Liu, Yuli; Whyte, Michael P; Giugliani, Roberto; Elliott, Dawn M; Haskins, Mark E; Ponder, Katherine P

    2012-01-01

    Mucopolysaccharidosis type VII (MPS VII) is characterized by deficient β-glucuronidase (GUSB) activity, which leads to accumulation of chondroitin, heparan and dermatan sulfate glycosaminoglycans (GAGs), and multisystemic disease. MPS VII patients can develop kypho-scoliotic deformity and spinal cord compression due to disease of intervertebral discs, vertebral bodies, and associated tissues. We have previously demonstrated in MPS VII dogs that intervertebral discs degenerate, vertebral bodies have irregular surfaces, and vertebral body epiphyses have reduced calcification, but the pathophysiological mechanisms underlying these changes are unclear. We hypothesized that some of these manifestations could be due to upregulation of destructive proteases, possibly via the binding of GAGs to Toll-like receptor 4 (TLR4), as has been proposed for other tissues in MPS models. In this study, the annulus fibrosus of the intervertebral disc of 6 month-old MPS VII dogs had cathepsin B and K activities that were 117- and 2-fold normal, respectively, which were associated with elevations in mRNA levels for cathepsins as well as TLR4. The epiphyses of MPS VII dogs had a marked elevation in mRNA for the cartilage-associated gene collagen II, consistent with a developmental delay in the conversion of the cartilage to bone in this region. A spine from a human patient with MPS VII exhibited similar increased cartilage in the vertebral bodies adjacent to the end plates, disorganization of the intervertebral discs, and irregular vertebral end plate morphology. These data suggest that the pathogenesis of destructive changes in the spine in MPS VII may involve upregulation of cathepsins. Inhibition of destructive proteases, such as cathepsins, might reduce spine disease in patients with MPS VII or related disorders. PMID:22513347

  20. Stereoscopic visualization and haptic technology used to create a virtual environment for remote surgery - biomed 2011.

    PubMed

    Bornhoft, J M; Strabala, K W; Wortman, T D; Lehman, A C; Oleynikov, D; Farritor, S M

    2011-01-01

    The objective of this research is to study the effectiveness of using a stereoscopic visualization system for performing remote surgery. The use of stereoscopic vision has become common with the advent of the da Vinci® system (Intuitive, Sunnyvale CA). This system creates a virtual environment that consists of a 3-D display for visual feedback and haptic tactile feedback, together providing an intuitive environment for remote surgical applications. This study will use simple in vivo robotic surgical devices and compare the performance of surgeons using the stereoscopic interfacing system to the performance of surgeons using one dimensional monitors. The stereoscopic viewing system consists of two cameras, two monitors, and four mirrors. The cameras are mounted to a multi-functional miniature in vivo robot; and mimic the depth perception of the actual human eyes. This is done by placing the cameras at a calculated angle and distance apart. Live video streams from the left and right cameras are displayed on the left and right monitors, respectively. A system of angled mirrors allows the left and right eyes to see the video stream from the left and right monitor, respectively, creating the illusion of depth. The haptic interface consists of two PHANTOM Omni® (SensAble, Woburn Ma) controllers. These controllers measure the position and orientation of a pen-like end effector with three degrees of freedom. As the surgeon uses this interface, they see a 3-D image and feel force feedback for collision and workspace limits. The stereoscopic viewing system has been used in several surgical training tests and shows a potential improvement in depth perception and 3-D vision. The haptic system accurately gives force feedback that aids in surgery. Both have been used in non-survival animal surgeries, and have successfully been used in suturing and gallbladder removal. Bench top experiments using the interfacing system have also been conducted. A group of participants completed

  1. Identification of depth information with stereoscopic mammography using different display methods

    NASA Astrophysics Data System (ADS)

    Morikawa, Takamitsu; Kodera, Yoshie

    2013-03-01

    Stereoscopy in radiography was widely used in the late 80's because it could be used for capturing complex structures in the human body, thus proving beneficial for diagnosis and screening. When radiologists observed the images stereoscopically, radiologists usually needed the training of their eyes in order to perceive the stereoscopic effect. However, with the development of three-dimensional (3D) monitors and their use in the medical field, only a visual inspection is no longer required in the medical field. The question then arises as to whether there is any difference in recognizing depth information when using conventional methods and that when using a 3D monitor. We constructed a phantom and evaluated the difference in capacity to identify the depth information between the two methods. The phantom consists of acryl steps and 3mm diameter acryl pillars on the top and bottom of each step. Seven observers viewed these images stereoscopically using the two display methods and were asked to judge the direction of the pillar that was on the top. We compared these judged direction with the direction of the real pillar arranged on the top, and calculated the percentage of correct answerers (PCA). The results showed that PCA obtained using the 3D monitor method was higher PCA by about 5% than that obtained using the naked-eye method. This indicated that people could view images stereoscopically more precisely using the 3D monitor method than when using with conventional methods, like the crossed or parallel eye viewing. We were able to estimate the difference in capacity to identify the depth information between the two display methods.

  2. Evaluation of stereoscopic medical video content on an autostereoscopic display for undergraduate medical education

    NASA Astrophysics Data System (ADS)

    Ilgner, Justus F. R.; Kawai, Takashi; Shibata, Takashi; Yamazoe, Takashi; Westhofen, Martin

    2006-02-01

    Introduction: An increasing number of surgical procedures are performed in a microsurgical and minimally-invasive fashion. However, the performance of surgery, its possibilities and limitations become difficult to teach. Stereoscopic video has evolved from a complex production process and expensive hardware towards rapid editing of video streams with standard and HDTV resolution which can be displayed on portable equipment. This study evaluates the usefulness of stereoscopic video in teaching undergraduate medical students. Material and methods: From an earlier study we chose two clips each of three different microsurgical operations (tympanoplasty type III of the ear, endonasal operation of the paranasal sinuses and laser chordectomy for carcinoma of the larynx). This material was added by 23 clips of a cochlear implantation, which was specifically edited for a portable computer with an autostereoscopic display (PC-RD1-3D, SHARP Corp., Japan). The recording and synchronization of left and right image was performed at the University Hospital Aachen. The footage was edited stereoscopically at the Waseda University by means of our original software for non-linear editing of stereoscopic 3-D movies. Then the material was converted into the streaming 3-D video format. The purpose of the conversion was to present the video clips by a file type that does not depend on a television signal such as PAL or NTSC. 25 4th year medical students who participated in the general ENT course at Aachen University Hospital were asked to estimate depth clues within the six video clips plus cochlear implantation clips. Another 25 4th year students who were shown the material monoscopically on a conventional laptop served as control. Results: All participants noted that the additional depth information helped with understanding the relation of anatomical structures, even though none had hands-on experience with Ear, Nose and Throat operations before or during the course. The monoscopic

  3. Use of recombinant factor VII for tooth extractions in a patient with severe congenital factor VII deficiency: a case report.

    PubMed

    Weinstock, Robert J; Onyejiuwa, Andrew; Shnayder, Garry; Clarkson, Earl I

    2015-04-01

    Patients with factor VII deficiency have an increased risk of prolonged perioperative hemorrhage. In this article, the authors present a case of severe factor VII deficiency in a patient who required tooth extraction. A 44-year-old woman with severe congenital factor VII deficiency sought care for a symptomatic, carious, and nonrestorable maxillary right second molar that required extraction. The authors obtained hematologic consultation, and the patient underwent the extraction under general anesthesia in the inpatient setting. Perioperative management included performing relevant laboratory studies, preoperative recombinant factor VII infusion, and postoperative intravenous aminocaproic acid administration. No hemorrhagic complications occurred throughout the perioperative course. The degree of factor VII deficiency correlates poorly with bleeding risk. Perioperative management is variable, requiring preoperative consultation with a hematologist. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  4. Synergistic effect of factor VII gene polymorphisms causing mild factor VII deficiency in a case of severe factor X deficiency.

    PubMed

    Deshpande, Rutuja; Ghosh, Kanjaksha; Shetty, Shrimati

    2017-01-01

    Congenital combined deficiency of coagulation factors VII and X are mainly attributed to large deletions involving both the genes in chromosome 13 or occasionally due to the coincidental occurrence of independently occurring mutations. We report the molecular basis of congenital combined deficiency of factors VII and X in a 6-year-old female child. Direct DNA sequencing of both factor VII (F7) and factor X (F10) genes showed a novel homozygous missense mutation p.Cys90Tyr (c.307G>A) in exon 4 of F10. No mutations were detected in F7; however, the patient was homozygous for three polymorphic alleles known to be associated with reduced factor VII levels. The present case illustrates the synergistic effect of multiple polymorphisms resulting in phenotypic factor VII deficiency in the absence of a pathogenic mutation.

  5. Visual discomfort in stereoscopic displays: a review

    NASA Astrophysics Data System (ADS)

    Lambooij, Marc T. M.; IJsselsteijn, Wijnand A.; Heynderickx, Ingrid

    2007-02-01

    Visual discomfort has been the subject of considerable research in relation to stereoscopic and autostereoscopic displays, but remains an ambiguous concept used to denote a variety of subjective symptoms potentially related to different underlying processes. In this paper we clarify the importance of various causes and aspects of visual comfort. Classical causative factors such as excessive binocular parallax and accommodation-convergence conflict appear to be of minor importance when disparity values do not surpass one degree limit of visual angle, which still provides sufficient range to allow for satisfactory depth perception in consumer applications, such as stereoscopic television. Visual discomfort, however, may still occur within this limit and we believe the following factors to be the most pertinent in contributing to this: (1) excessive demand of accommodation-convergence linkage, e.g., by fast motion in depth, viewed at short distances, (2) 3D artefacts resulting from insufficient depth information in the incoming data signal yielding spatial and temporal inconsistencies, and (3) unnatural amounts of blur. In order to adequately characterize and understand visual discomfort, multiple types of measurements, both objective and subjective, are needed.

  6. Stereoscopic Three-Dimensional Neuroanatomy Lectures Enhance Neurosurgical Training: Prospective Comparison with Traditional Teaching.

    PubMed

    Clark, Anna D; Guilfoyle, Mathew R; Candy, Nicholas G; Budohoski, Karol P; Hofmann, Riikka; Barone, Damiano G; Santarius, Thomas; Kirollos, Ramez W; Trivedi, Rikin A

    2017-12-01

    Stereoscopic three-dimensional (3D) imaging is increasingly used in the teaching of neuroanatomy and although this is mainly aimed at undergraduate medical students, it has enormous potential for enhancing the training of neurosurgeons. This study aims to assess whether 3D lecturing is an effective method of enhancing the knowledge and confidence of neurosurgeons and how it compares with traditional two-dimensional (2D) lecturing and cadaveric training. Three separate teaching sessions for neurosurgical trainees were organized: 1) 2D course (2D lecture + cadaveric session), 2) 3D lecture alone, and 3) 3D course (3D lecture + cadaveric session). Before and after each session, delegates were asked to complete questionnaires containing questions relating to surgical experience, anatomic knowledge, confidence in performing procedures, and perceived value of 3D, 2D, and cadaveric teaching. Although both 2D and 3D lectures and courses were similarly effective at improving self-rated knowledge and understanding, the 3D lecture and course were associated with significantly greater gains in confidence reported by the delegates for performing a subfrontal approach and sylvian fissure dissection. Stereoscopic 3D lectures provide neurosurgical trainees with greater confidence for performing standard operative approaches and enhances the benefit of subsequent practical experience in developing technical skills in cadaveric dissection. Copyright © 2017. Published by Elsevier Inc.

  7. A systematized WYSIWYG pipeline for digital stereoscopic 3D filmmaking

    NASA Astrophysics Data System (ADS)

    Mueller, Robert; Ward, Chris; Hušák, Michal

    2008-02-01

    Digital tools are transforming stereoscopic 3D content creation and delivery, creating an opportunity for the broad acceptance and success of stereoscopic 3D films. Beginning in late 2005, a series of mostly CGI features has successfully initiated the public to this new generation of highly-comfortable, artifact-free digital 3D. While the response has been decidedly favorable, a lack of high-quality live-action films could hinder long-term success. Liveaction stereoscopic films have historically been more time-consuming, costly, and creatively-limiting than 2D films - thus a need arises for a live-action 3D filmmaking process which minimizes such limitations. A unique 'systematized' what-you-see-is-what-you-get (WYSIWYG) pipeline is described which allows the efficient, intuitive and accurate capture and integration of 3D and 2D elements from multiple shoots and sources - both live-action and CGI. Throughout this pipeline, digital tools utilize a consistent algorithm to provide meaningful and accurate visual depth references with respect to the viewing audience in the target theater environment. This intuitive, visual approach introduces efficiency and creativity to the 3D filmmaking process by eliminating both the need for a 'mathematician mentality' of spreadsheets and calculators, as well as any trial and error guesswork, while enabling the most comfortable, 'pixel-perfect', artifact-free 3D product possible.

  8. Teaching with Stereoscopic Video: Opportunities and Challenges

    NASA Astrophysics Data System (ADS)

    Variano, Evan

    2017-11-01

    I will present my work on creating stereoscopic videos for fluid pedagogy. I discuss a variety of workflows for content creation and a variety of platforms for content delivery. I review the qualitative lessons learned when teaching with this material, and discuss outlook for the future. This work was partially supported by the NSF award ENG-1604026 and the UC Berkeley Student Technology Fund.

  9. Development of 40-in hybrid hologram screen for auto-stereoscopic video display

    NASA Astrophysics Data System (ADS)

    Song, Hyun Ho; Nakashima, Y.; Momonoi, Y.; Honda, Toshio

    2004-06-01

    Usually in auto stereoscopic display, there are two problems. The first problem is that large image display is difficult, and the second problem is that the view zone (which means the zone in which both eyes are put for stereoscopic or 3-D image observation) is very narrow. We have been developing an auto stereoscopic large video display system (over 100 inches diagonal) which a few people can view simultaneously1,2. Usually in displays that are over 100 inches diagonal, an optical video projection system is used. As one of auto stereoscopic display systems the hologram screen has been proposed3,4,5,6. However, if the hologram screen becomes too large, the view zone (corresponding to the reconstructed diffused object) causes color dispersion and color aberration7. We also proposed the additional Fresnel lens attached to the hologram screen. We call the screen a "hybrid hologram screen", (HHS in short). We made the HHS 866mm(H)×433mm(V) (about 40 inch diagonal)8,9,10,11. By using the lens in the reconstruction step, the angle between object light and reference light can be small, compared to without the lens. So, the spread of the view zone by the color dispersion and color aberration becomes small. And also, the virtual image which is reconstructed from the hologram screen can be transformed to a real image (view zone). So, it is not necessary to use a large lens or concave mirror while making a large hologram screen.

  10. Evaluating visual discomfort in stereoscopic projection-based CAVE system with a close viewing distance

    NASA Astrophysics Data System (ADS)

    Song, Weitao; Weng, Dongdong; Feng, Dan; Li, Yuqian; Liu, Yue; Wang, Yongtian

    2015-05-01

    As one of popular immersive Virtual Reality (VR) systems, stereoscopic cave automatic virtual environment (CAVE) system is typically consisted of 4 to 6 3m-by-3m sides of a room made of rear-projected screens. While many endeavors have been made to reduce the size of the projection-based CAVE system, the issue of asthenopia caused by lengthy exposure to stereoscopic images in such CAVE with a close viewing distance was seldom tangled. In this paper, we propose a light-weighted approach which utilizes a convex eyepiece to reduce visual discomfort induced by stereoscopic vision. An empirical experiment was conducted to examine the feasibility of convex eyepiece in a large depth of field (DOF) at close viewing distance both objectively and subjectively. The result shows the positive effects of convex eyepiece on the relief of eyestrain.

  11. 19 CFR Annex Vii to Part 351 - Antidumping Investigations Timeline

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Antidumping Investigations Timeline VII Annex VII to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VII Annex VII to Part 351—Antidumping Investigations Timeline ER19MY97.001 ...

  12. 19 CFR Annex Vii to Part 351 - Antidumping Investigations Timeline

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 3 2014-04-01 2014-04-01 false Antidumping Investigations Timeline VII Annex VII to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VII Annex VII to Part 351—Antidumping Investigations Timeline ER19MY97.001 ...

  13. 19 CFR Annex Vii to Part 351 - Antidumping Investigations Timeline

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 3 2011-04-01 2011-04-01 false Antidumping Investigations Timeline VII Annex VII to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VII Annex VII to Part 351—Antidumping Investigations Timeline ER19MY97.001 ...

  14. 19 CFR Annex Vii to Part 351 - Antidumping Investigations Timeline

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 3 2013-04-01 2013-04-01 false Antidumping Investigations Timeline VII Annex VII to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VII Annex VII to Part 351—Antidumping Investigations Timeline ER19MY97.001 ...

  15. 19 CFR Annex Vii to Part 351 - Antidumping Investigations Timeline

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 3 2012-04-01 2012-04-01 false Antidumping Investigations Timeline VII Annex VII to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VII Annex VII to Part 351—Antidumping Investigations Timeline ER19MY97.001 ...

  16. First living-related liver transplant to cure factor VII deficiency.

    PubMed

    Mohan, Neelam; Karkra, Sakshi; Jolly, Anu S; Vohra, Vijay; Mohanka, Ravi; Rastogi, Amit; Soin, A S

    2015-09-01

    Congenital factor VII deficiency is an autosomal recessive serious disorder of blood coagulation with wide genotypic and phenotypic variations. The clinical presentation can vary from asymptomatic patients to patients with major bleedings in severe deficiency (factor VII <1%). Investigations show prolonged PT and low factor VII. Treatment modalities include FFP and repeated recombinant factor VII infusions. We hereby report the first successful LRLT for factor VII deficiency in an infant, the first-ever youngest baby reported worldwide. A six-month-old male child presented with easy bruisability, ecchymotic patches, hematuria, and convulsions. CT of the head showed subdural hemorrhage, which was treated conservatively. He had markedly increased PT (120 s) with normal platelets, and aPTT with factor VII level <1%. Despite the treatment by rFVIIa administration weekly, which was very expensive, he still had repeated life-threatening bleeding episodes. LRLT was performed with mother as the donor, whose factor VII level was 57%. A factor VII infusion plan for pre-, intra- and postoperative periods was formulated and TEG followed. Postoperatively, his factor VII started increasing from third day and was 38% on 24th day with PT <14 s. He had uneventful intraoperative and postoperative courses. LT is a safe and definite cure for factor VII deficiency. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Topical application of recombinant activated factor VII during cesarean delivery for placenta previa.

    PubMed

    Schjoldager, Birgit T B G; Mikkelsen, Emmeli; Lykke, Malene R; Præst, Jørgen; Hvas, Anne-Mette; Heslet, Lars; Secher, Niels J; Salvig, Jannie D; Uldbjerg, Niels

    2017-06-01

    During cesarean delivery in patients with placenta previa, hemorrhaging after removal of the placenta is often challenging. In this condition, the extraordinarily high concentration of tissue factor at the placenta site may constitute a principle of treatment as it activates coagulation very effectively. The presumption, however, is that tissue factor is bound to activated factor VII. We hypothesized that topical application of recombinant activated factor VII at the placenta site reduces bleeding without affecting intravascular coagulation. We included 5 cases with planned cesarean delivery for placenta previa. After removal of the placenta, the surgeon applied a swab soaked in recombinant activated factor VII containing saline (1 mg in 246 mL) to the placenta site for 2 minutes; this treatment was repeated once if the bleeding did not decrease sufficiently. We documented the treatment on video recordings and measured blood loss. Furthermore, we determined hemoglobin concentration, platelet count, international normalized ratio, activated partial thrombin time, fibrinogen (functional), factor VII:clot, and thrombin generation in peripheral blood prior to and 15 minutes after removal of the placenta. We also tested these blood coagulation variables in 5 women with cesarean delivery planned for other reasons. Mann-Whitney test was used for unpaired data. In all 5 cases, the uterotomy was closed under practically dry conditions and the median blood loss was 490 (range 300-800) mL. There were no adverse effects of recombinant activated factor VII and we did not measure factor VII to enter the circulation. Neither did we observe changes in thrombin generation, fibrinogen, activated partial thrombin time, international normalized ratio, and platelet count in the peripheral circulation (all P values >.20). This study indicates that in patients with placenta previa, topical recombinant activated factor VII may diminish bleeding from the placenta site without initiation

  18. Architecture for high performance stereoscopic game rendering on Android

    NASA Astrophysics Data System (ADS)

    Flack, Julien; Sanderson, Hugh; Shetty, Sampath

    2014-03-01

    Stereoscopic gaming is a popular source of content for consumer 3D display systems. There has been a significant shift in the gaming industry towards casual games for mobile devices running on the Android™ Operating System and driven by ARM™ and other low power processors. Such systems are now being integrated directly into the next generation of 3D TVs potentially removing the requirement for an external games console. Although native stereo support has been integrated into some high profile titles on established platforms like Windows PC and PS3 there is a lack of GPU independent 3D support for the emerging Android platform. We describe a framework for enabling stereoscopic 3D gaming on Android for applications on mobile devices, set top boxes and TVs. A core component of the architecture is a 3D game driver, which is integrated into the Android OpenGL™ ES graphics stack to convert existing 2D graphics applications into stereoscopic 3D in real-time. The architecture includes a method of analyzing 2D games and using rule based Artificial Intelligence (AI) to position separate objects in 3D space. We describe an innovative stereo 3D rendering technique to separate the views in the depth domain and render directly into the display buffer. The advantages of the stereo renderer are demonstrated by characterizing the performance in comparison to more traditional render techniques, including depth based image rendering, both in terms of frame rates and impact on battery consumption.

  19. Effect of image scaling on stereoscopic movie experience

    NASA Astrophysics Data System (ADS)

    Häkkinen, Jukka P.; Hakala, Jussi; Hannuksela, Miska; Oittinen, Pirkko

    2011-03-01

    Camera separation affects the perceived depth in stereoscopic movies. Through control of the separation and thereby the depth magnitudes, the movie can be kept comfortable but interesting. In addition, the viewing context has a significant effect on the perceived depth, as a larger display and longer viewing distances also contribute to an increase in depth. Thus, if the content is to be viewed in multiple viewing contexts, the depth magnitudes should be carefully planned so that the content always looks acceptable. Alternatively, the content can be modified for each viewing situation. To identify the significance of changes due to the viewing context, we studied the effect of stereoscopic camera base distance on the viewer experience in three different situations: 1) small sized video and a viewing distance of 38 cm, 2) television and a viewing distance of 158 cm, and 3) cinema and a viewing distance of 6-19 meters. We examined three different animations with positive parallax. The results showed that the camera distance had a significant effect on the viewing experience in small display/short viewing distance situations, in which the experience ratings increased until the maximum disparity in the scene was 0.34 - 0.45 degrees of visual angle. After 0.45 degrees, increasing the depth magnitude did not affect the experienced quality ratings. Interestingly, changes in the camera distance did not affect the experience ratings in the case of television or cinema if the depth magnitudes were below one degree of visual angle. When the depth was greater than one degree, the experience ratings began to drop significantly. These results indicate that depth magnitudes have a larger effect on the viewing experience with a small display. When a stereoscopic movie is viewed from a larger display, other experiences might override the effect of depth magnitudes.

  20. An interactive, stereoscopic virtual environment for medical imaging visualization, simulation and training

    NASA Astrophysics Data System (ADS)

    Krueger, Evan; Messier, Erik; Linte, Cristian A.; Diaz, Gabriel

    2017-03-01

    Recent advances in medical image acquisition allow for the reconstruction of anatomies with 3D, 4D, and 5D renderings. Nevertheless, standard anatomical and medical data visualization still relies heavily on the use of traditional 2D didactic tools (i.e., textbooks and slides), which restrict the presentation of image data to a 2D slice format. While these approaches have their merits beyond being cost effective and easy to disseminate, anatomy is inherently three-dimensional. By using 2D visualizations to illustrate more complex morphologies, important interactions between structures can be missed. In practice, such as in the planning and execution of surgical interventions, professionals require intricate knowledge of anatomical complexities, which can be more clearly communicated and understood through intuitive interaction with 3D volumetric datasets, such as those extracted from high-resolution CT or MRI scans. Open source, high quality, 3D medical imaging datasets are freely available, and with the emerging popularity of 3D display technologies, affordable and consistent 3D anatomical visualizations can be created. In this study we describe the design, implementation, and evaluation of one such interactive, stereoscopic visualization paradigm for human anatomy extracted from 3D medical images. A stereoscopic display was created by projecting the scene onto the lab floor using sequential frame stereo projection and viewed through active shutter glasses. By incorporating a PhaseSpace motion tracking system, a single viewer can navigate an augmented reality environment and directly manipulate virtual objects in 3D. While this paradigm is sufficiently versatile to enable a wide variety of applications in need of 3D visualization, we designed our study to work as an interactive game, which allows users to explore the anatomy of various organs and systems. In this study we describe the design, implementation, and evaluation of an interactive and stereoscopic

  1. Effects of Seating Location and Stereoscopic Display on Learning Outcomes in an Introductory Physical Geography Class

    ERIC Educational Resources Information Center

    Hirmas, Daniel R.; Slocum, Terry; Halfen, Alan F.; White, Travis; Zautner, Eric; Atchley, Paul; Liu, Huan; Johnson, William C.; Egbert, Stephen; McDermott, Dave

    2014-01-01

    Recently, the use of stereoscopic three-dimensional (3-D) projection displays has increased in geoscience education. One concern in employing 3-D projection systems in large lecture halls, however, is that the 3-D effect is reported to diminish with increased angle and distance from the stereoscopic display. The goal of this work was to study that…

  2. Analysis of Performance of Stereoscopic-Vision Software

    NASA Technical Reports Server (NTRS)

    Kim, Won; Ansar, Adnan; Steele, Robert; Steinke, Robert

    2007-01-01

    A team of JPL researchers has analyzed stereoscopic vision software and produced a document describing its performance. This software is of the type used in maneuvering exploratory robotic vehicles on Martian terrain. The software in question utilizes correlations between portions of the images recorded by two electronic cameras to compute stereoscopic disparities, which, in conjunction with camera models, are used in computing distances to terrain points to be included in constructing a three-dimensional model of the terrain. The analysis included effects of correlation- window size, a pyramidal image down-sampling scheme, vertical misalignment, focus, maximum disparity, stereo baseline, and range ripples. Contributions of sub-pixel interpolation, vertical misalignment, and foreshortening to stereo correlation error were examined theoretically and experimentally. It was found that camera-calibration inaccuracy contributes to both down-range and cross-range error but stereo correlation error affects only the down-range error. Experimental data for quantifying the stereo disparity error were obtained by use of reflective metrological targets taped to corners of bricks placed at known positions relative to the cameras. For the particular 1,024-by-768-pixel cameras of the system analyzed, the standard deviation of the down-range disparity error was found to be 0.32 pixel.

  3. Stereoscopic visual fatigue assessment and modeling

    NASA Astrophysics Data System (ADS)

    Wang, Danli; Wang, Tingting; Gong, Yue

    2014-03-01

    Evaluation of stereoscopic visual fatigue is one of the focuses in the user experience research. It is measured in either subjective or objective methods. Objective measures are more preferred for their capability to quantify the degree of human visual fatigue without being affected by individual variation. However, little research has been conducted on the integration of objective indicators, or the sensibility of each objective indicator in reflecting subjective fatigue. The paper proposes a simply effective method to evaluate visual fatigue more objectively. The stereoscopic viewing process is divided into series of sessions, after each of which viewers rate their visual fatigue with subjective scores (SS) according to a five-grading scale, followed by tests of the punctum maximum accommodation (PMA) and visual reaction time (VRT). Throughout the entire viewing process, their eye movements are recorded by an infrared camera. The pupil size (PS) and percentage of eyelid closure over the pupil over time (PERCLOS) are extracted from the videos processed by the algorithm. Based on the method, an experiment with 14 subjects was conducted to assess visual fatigue induced by 3D images on polarized 3D display. The experiment consisted of 10 sessions (5min per session), each containing the same 75 images displayed randomly. The results show that PMA, VRT and PERCLOS are the most efficient indicators of subjective visual fatigue and finally a predictive model is derived from the stepwise multiple regressions.

  4. A product Pearson-type VII density distribution

    NASA Astrophysics Data System (ADS)

    Nadarajah, Saralees; Kotz, Samuel

    2008-01-01

    The Pearson-type VII distributions (containing the Student's t distributions) are becoming increasing prominent and are being considered as competitors to the normal distribution. Motivated by real examples in decision sciences, Bayesian statistics, probability theory and Physics, a new Pearson-type VII distribution is introduced by taking the product of two Pearson-type VII pdfs. Various structural properties of this distribution are derived, including its cdf, moments, mean deviation about the mean, mean deviation about the median, entropy, asymptotic distribution of the extreme order statistics, maximum likelihood estimates and the Fisher information matrix. Finally, an application to a Bayesian testing problem is illustrated.

  5. Perfect 3-D movies and stereoscopic movies on TV and projection screens: an appraisement

    NASA Astrophysics Data System (ADS)

    Klein, Susanne; Dultz, Wolfgang

    1990-09-01

    Since the invention of stereoscopy (WHEATSTONE 1838) reasons for and against 3-dimensional images have occupied the literature, but there has never been much doubt about the preference of autostereoscopic systems showing a scene which is 3-dimensional and true to life from all sides (perfect 3-dimensional image, HESSE 1939), especially since most stereoscopic movies of the past show serious imperfections with respect to image quality and technical operation. Leave aside that no convincing perfect 3D-TV-system is in sight, there are properties f the stereoscopic movie which are advantageous to certain representations on TV and important for the 3-dimensional motion picture. In this paper we investigate the influence of apparent motions of 3-dimensional images and classify the different projection systems with respect to presence and absence of these spectacular illusions. Apparent motions bring dramatic effects into stereoscopic movies which cannot be created with perfect 3-dimensional systems. In this study we describe their applications and limits for television.

  6. Recombinant activated factor VII in cardiac surgery: single-center experience.

    PubMed

    Singh, Sarvesh Pal; Chauhan, Sandeep; Choudhury, Minati; Malik, Vishwas; Choudhary, Shiv Kumar

    2014-02-01

    The widespread off-label use of recombinant activated factor VII for the control of refractory postoperative hemorrhage continues despite a warning from the Food and Drug Administration. Although effective in reducing the need for transfusion of blood and blood products, safety concerns still prevail. To compare the dosing and efficacy of recombinant activated factor VII between pediatric and adult patients, and in the operating room and intensive care unit. The records of 69 patients (33 children and 36 adults) who underwent cardiovascular surgery and received recombinant activated factor VII were reviewed retrospectively. The dose of recombinant activated factor VII, mediastinal drainage, use of blood and blood products, incidence of thrombosis, and 28-day mortality were studied. the efficacy of recombinant activated factor VII was comparable in adults and children, despite the lower dose in adults. Prophylactic use of recombinant activated factor VII decreased the incidence of mediastinal exploration and the duration of intensive care unit stay. A 4.3% incidence of thrombotic complications was observed in this study. The efficacious dose of recombinant activated factor VII is much less in adults compared to children. Prophylactic use of recombinant activated factor VII decreases the dose required, the incidence of mediastinal exploration, and intensive care unit stay, with no survival benefit.

  7. Stereoscopic optical viewing system

    DOEpatents

    Tallman, C.S.

    1986-05-02

    An improved optical system which provides the operator with a stereoscopic viewing field and depth of vision, particularly suitable for use in various machines such as electron or laser beam welding and drilling machines. The system features two separate but independently controlled optical viewing assemblies from the eyepiece to a spot directly above the working surface. Each optical assembly comprises a combination of eye pieces, turning prisms, telephoto lenses for providing magnification, achromatic imaging relay lenses and final stage pentagonal turning prisms. Adjustment for variations in distance from the turning prisms to the workpiece, necessitated by varying part sizes and configurations and by the operator's visual accuity, is provided separately for each optical assembly by means of separate manual controls at the operator console or within easy reach of the operator.

  8. Stereoscopic optical viewing system

    DOEpatents

    Tallman, Clifford S.

    1987-01-01

    An improved optical system which provides the operator a stereoscopic viewing field and depth of vision, particularly suitable for use in various machines such as electron or laser beam welding and drilling machines. The system features two separate but independently controlled optical viewing assemblies from the eyepiece to a spot directly above the working surface. Each optical assembly comprises a combination of eye pieces, turning prisms, telephoto lenses for providing magnification, achromatic imaging relay lenses and final stage pentagonal turning prisms. Adjustment for variations in distance from the turning prisms to the workpiece, necessitated by varying part sizes and configurations and by the operator's visual accuity, is provided separately for each optical assembly by means of separate manual controls at the operator console or within easy reach of the operator.

  9. Diffuse nitrogen loss simulation and impact assessment of stereoscopic agriculture pattern by integrated water system model and consideration of multiple existence forms

    NASA Astrophysics Data System (ADS)

    Zhang, Yongyong; Gao, Yang; Yu, Qiang

    2017-09-01

    Agricultural nitrogen loss becomes an increasingly important source of water quality deterioration and eutrophication, even threatens water safety for humanity. Nitrogen dynamic mechanism is still too complicated to be well captured at watershed scale due to its multiple existence forms and instability, disturbance of agricultural management practices. Stereoscopic agriculture is a novel agricultural planting pattern to efficiently use local natural resources (e.g., water, land, sunshine, heat and fertilizer). It is widely promoted as a high yield system and can obtain considerable economic benefits, particularly in China. However, its environmental quality implication is not clear. In our study, Qianyanzhou station is famous for its stereoscopic agriculture pattern of Southern China, and an experimental watershed was selected as our study area. Regional characteristics of runoff and nitrogen losses were simulated by an integrated water system model (HEQM) with multi-objective calibration, and multiple agriculture practices were assessed to find the effective approach for the reduction of diffuse nitrogen losses. Results showed that daily variations of runoff and nitrogen forms were well reproduced throughout watershed, i.e., satisfactory performances for ammonium and nitrate nitrogen (NH4-N and NO3-N) loads, good performances for runoff and organic nitrogen (ON) load, and very good performance for total nitrogen (TN) load. The average loss coefficient was 62.74 kg/ha for NH4-N, 0.98 kg/ha for NO3-N, 0.0004 kg/ha for ON and 63.80 kg/ha for TN. The dominating form of nitrogen losses was NH4-N due to the applied fertilizers, and the most dramatic zones aggregated in the middle and downstream regions covered by paddy and orange orchard. In order to control diffuse nitrogen losses, the most effective practices for Qianyanzhou stereoscopic agriculture pattern were to reduce farmland planting scale in the valley by afforestation, particularly for orchard in the

  10. Stereoscopic Movies for Teaching and Learning of Astronomy

    NASA Astrophysics Data System (ADS)

    Hayashi, Mitsuru; Kato, Tsunehiko N.; Takeda, Takaaaki; Kokubo, Eiichiro; Miura, Hitoshi; Takahei, Toshiyuki; Miyama, Shoken M.; Kaifu, Norio

    To attract the interest of the public in astronomy we visualize data obtained through simulations by using super computers and observations by using state-of -the-art facilities for example the SUBARU Telescope in the virtual reality system. The system is composed of three soft screens. We use two PC's two DLP projectors with circular polarization filters and one mirror for each screen to realize stereoscopic projection. By wearing glasses of circular polarization filters we can experience immersiveness in the system. Six PC's are connected by using optical fiber cable(1Gbps). Especially we developed the software for synchronization and realized stereoscopic movies(15-30 frames per second). In addition to teaching and learning of astronomy we also utilize the system above for public relations and science itself in NAO Mitaka. The system can provide scientists with the point of view we cannot realize on the earth. We are planning to improve the contents easier for the public to understand and distribute the contents to museums and educational institutions through networks for example Super SINET(the internet backbone connects institutes at 10Gbps) in 2003 in addition to monthly exhibition in NAOMitaka

  11. Teaching-learning: stereoscopic 3D versus Traditional methods in Mexico City.

    PubMed

    Mendoza Oropeza, Laura; Ortiz Sánchez, Ricardo; Ojeda Villagómez, Raúl

    2015-01-01

    In the UNAM Faculty of Odontology, we use a stereoscopic 3D teaching method that has grown more common in the last year, which makes it important to know whether students can learn better with this strategy. The objective of the study is to know, if the 4th year students of the bachelor's degree in dentistry learn more effectively with the use of stereoscopic 3D than the traditional method in Orthodontics. first, we selected the course topics, to be used for both methods; the traditional method using projection of slides and for the stereoscopic third dimension, with the use of videos in digital stereo projection (seen through "passive" polarized 3D glasses). The main topic was supernumerary teeth, including and diverted from their guide eruption. Afterwards we performed an exam on students, containing 24 items, validated by expert judgment in Orthodontics teaching. The results of the data were compared between the two educational methods for determined effectiveness using the model before and after measurement with the statistical package SPSS 20 version. The results presented for the 9 groups of undergraduates in dentistry, were collected with a total of 218 students for 3D and traditional methods, we found in a traditional method a mean 4.91, SD 1.4752 in the pretest and X=6.96, SD 1.26622, St Error 0.12318 for the posttest. The 3D method had a mean 5.21, SD 1.996779 St Error 0.193036 for the pretest X= 7.82, SD =0.963963, St Error 0.09319 posttest; the analysis of Variance between groups F= 5.60 Prob > 0.0000 and Bartlett's test for equal variances 21.0640 Prob > chi2 = 0.007. These results show that the student's learning in 3D means a significant improvement as compared to the traditional teaching method and having a strong association between the two methods. The findings suggest that the stereoscopic 3D method lead to improved student learning compared to traditional teaching.

  12. How much camera separation should be used for the capture and presentation of 3D stereoscopic imagery on binocular HMDs?

    NASA Astrophysics Data System (ADS)

    McIntire, John; Geiselman, Eric; Heft, Eric; Havig, Paul

    2011-06-01

    Designers, researchers, and users of binocular stereoscopic head- or helmet-mounted displays (HMDs) face the tricky issue of what imagery to present in their particular displays, and how to do so effectively. Stereoscopic imagery must often be created in-house with a 3D graphics program or from within a 3D virtual environment, or stereoscopic photos/videos must be carefully captured, perhaps for relaying to an operator in a teleoperative system. In such situations, the question arises as to what camera separation (real or virtual) is appropriate or desirable for end-users and operators. We review some of the relevant literature regarding the question of stereo pair camera separation using deskmounted or larger scale stereoscopic displays, and employ our findings to potential HMD applications, including command & control, teleoperation, information and scientific visualization, and entertainment.

  13. LEA Title VII Program Evaluations. Panel Presentations.

    ERIC Educational Resources Information Center

    Balu, Raj

    These panel presentations focus on LEA Title VII Program Evaluations. Raj Balu, an administrator of bilingual programs in Chicago presents information regarding the bilingual education program in the Chicago public schools, as well as information on Title VII programs and what kind of evaluation is being done. Jesus Salazar, who is currently…

  14. Continuous monitoring of prostate position using stereoscopic and monoscopic kV image guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stevens, M. Tynan R.; Parsons, Dave D.; Robar, James L.

    2016-05-15

    Purpose: To demonstrate continuous kV x-ray monitoring of prostate motion using both stereoscopic and monoscopic localizations, assess the spatial accuracy of these techniques, and evaluate the dose delivered from the added image guidance. Methods: The authors implemented both stereoscopic and monoscopic fiducial localizations using a room-mounted dual oblique x-ray system. Recently developed monoscopic 3D position estimation techniques potentially overcome the issue of treatment head interference with stereoscopic imaging at certain gantry angles. To demonstrate continuous position monitoring, a gold fiducial marker was placed in an anthropomorphic phantom and placed on the Linac couch. The couch was used as a programmablemore » translation stage. The couch was programmed with a series of patient prostate motion trajectories exemplifying five distinct categories: stable prostate, slow drift, persistent excursion, transient excursion, and high frequency excursions. The phantom and fiducial were imaged using 140 kVp, 0.63 mAs per image at 1 Hz for a 60 s monitoring period. Both stereoscopic and monoscopic 3D localization accuracies were assessed by comparison to the ground-truth obtained from the Linac log file. Imaging dose was also assessed, using optically stimulated luminescence dosimeter inserts in the phantom. Results: Stereoscopic localization accuracy varied between 0.13 ± 0.05 and 0.33 ± 0.30 mm, depending on the motion trajectory. Monoscopic localization accuracy varied from 0.2 ± 0.1 to 1.1 ± 0.7 mm. The largest localization errors were typically observed in the left–right direction. There were significant differences in accuracy between the two monoscopic views, but which view was better varied from trajectory to trajectory. The imaging dose was measured to be between 2 and 15 μGy/mAs, depending on location in the phantom. Conclusions: The authors have demonstrated the first use of monoscopic localization for a room-mounted dual x-ray system

  15. Clinical course of sly syndrome (mucopolysaccharidosis type VII)

    PubMed Central

    Montaño, Adriana M; Lock-Hock, Ngu; Steiner, Robert D; Graham, Brett H; Szlago, Marina; Greenstein, Robert; Pineda, Mercedes; Gonzalez-Meneses, Antonio; Çoker, Mahmut; Bartholomew, Dennis; Sands, Mark S; Wang, Raymond; Giugliani, Roberto; Macaya, Alfons; Pastores, Gregory; Ketko, Anastasia K; Ezgü, Fatih; Tanaka, Akemi; Arash, Laila; Beck, Michael; Falk, Rena E; Bhattacharya, Kaustuv; Franco, José; White, Klane K; Mitchell, Grant A; Cimbalistiene, Loreta; Holtz, Max; Sly, William S

    2016-01-01

    Background Mucopolysaccharidosis VII (MPS VII) is an ultra-rare disease characterised by the deficiency of β-glucuronidase (GUS). Patients’ phenotypes vary from severe forms with hydrops fetalis, skeletal dysplasia and mental retardation to milder forms with fewer manifestations and mild skeletal abnormalities. Accurate assessments on the frequency and clinical characteristics of the disease have been scarce. The aim of this study was to collect such data. Methods We have conducted a survey of physicians to document the medical history of patients with MPS VII. The survey included anonymous information on patient demographics, family history, mode of diagnosis, age of onset, signs and symptoms, severity, management, clinical features and natural progression of the disease. Results We collected information on 56 patients from 11 countries. Patients with MPS VII were classified based on their phenotype into three different groups: (1) neonatal non-immune hydrops fetalis (NIHF) (n=10), (2) Infantile or adolescent form with history of hydrops fetalis (n=13) and (3) Infantile or adolescent form without known hydrops fetalis (n=33). Thirteen patients with MPS VII who had the infantile form with history of hydrops fetalis and survived childhood, had a wide range of clinical manifestations from mild to severe. Five patients underwent bone marrow transplantation and one patient underwent enzyme replacement therapy with recombinant human GUS. Conclusions MPS VII is a pan-ethnic inherited lysosomal storage disease with considerable phenotypical heterogeneity. Most patients have short stature, skeletal dysplasia, hepatosplenomegaly, hernias, cardiac involvement, pulmonary insufficiency and cognitive impairment. In these respects it resembles MPS I and MPS II. In MPS VII, however, one unique and distinguishing clinical feature is the unexpectedly high proportion of patients (41%) that had a history of NIHF. Presence of NIHF does not, by itself, predict the eventual severity

  16. Learning Receptive Fields and Quality Lookups for Blind Quality Assessment of Stereoscopic Images.

    PubMed

    Shao, Feng; Lin, Weisi; Wang, Shanshan; Jiang, Gangyi; Yu, Mei; Dai, Qionghai

    2016-03-01

    Blind quality assessment of 3D images encounters more new challenges than its 2D counterparts. In this paper, we propose a blind quality assessment for stereoscopic images by learning the characteristics of receptive fields (RFs) from perspective of dictionary learning, and constructing quality lookups to replace human opinion scores without performance loss. The important feature of the proposed method is that we do not need a large set of samples of distorted stereoscopic images and the corresponding human opinion scores to learn a regression model. To be more specific, in the training phase, we learn local RFs (LRFs) and global RFs (GRFs) from the reference and distorted stereoscopic images, respectively, and construct their corresponding local quality lookups (LQLs) and global quality lookups (GQLs). In the testing phase, blind quality pooling can be easily achieved by searching optimal GRF and LRF indexes from the learnt LQLs and GQLs, and the quality score is obtained by combining the LRF and GRF indexes together. Experimental results on three publicly 3D image quality assessment databases demonstrate that in comparison with the existing methods, the devised algorithm achieves high consistent alignment with subjective assessment.

  17. Virtual workstation - A multimodal, stereoscopic display environment

    NASA Astrophysics Data System (ADS)

    Fisher, S. S.; McGreevy, M.; Humphries, J.; Robinett, W.

    1987-01-01

    A head-mounted, wide-angle, stereoscopic display system controlled by operator position, voice and gesture has been developed for use in a multipurpose interface environment. The system provides a multisensory, interactive display environment in which a user can virtually explore a 360-degree synthesized or remotely sensed environment and can viscerally interact with its components. Primary applications of the system are in telerobotics, management of large-scale integrated information systems, and human factors research. System configuration, application scenarios, and research directions are described.

  18. Comparison of form in potential functions while maintaining upright posture during exposure to stereoscopic video clips.

    PubMed

    Kutsuna, Kenichiro; Matsuura, Yasuyuki; Fujikake, Kazuhiro; Miyao, Masaru; Takada, Hiroki

    2013-01-01

    Visually induced motion sickness (VIMS) is caused by sensory conflict, the disagreement between vergence and visual accommodation while observing stereoscopic images. VIMS can be measured by psychological and physiological methods. We propose a mathematical methodology to measure the effect of three-dimensional (3D) images on the equilibrium function. In this study, body sway in the resting state is compared with that during exposure to 3D video clips on a liquid crystal display (LCD) and on a head mounted display (HMD). In addition, the Simulator Sickness Questionnaire (SSQ) was completed immediately afterward. Based on the statistical analysis of the SSQ subscores and each index for stabilograms, we succeeded in determining the quantity of the VIMS during exposure to the stereoscopic images. Moreover, we discuss the metamorphism in the potential functions to control the standing posture during the exposure to stereoscopic video clips.

  19. Tissue feature-based intra-fractional motion tracking for stereoscopic x-ray image guided radiotherapy

    NASA Astrophysics Data System (ADS)

    Xie, Yaoqin; Xing, Lei; Gu, Jia; Liu, Wu

    2013-06-01

    Real-time knowledge of tumor position during radiation therapy is essential to overcome the adverse effect of intra-fractional organ motion. The goal of this work is to develop a tumor tracking strategy by effectively utilizing the inherent image features of stereoscopic x-ray images acquired during dose delivery. In stereoscopic x-ray image guided radiation delivery, two orthogonal x-ray images are acquired either simultaneously or sequentially. The essence of markerless tumor tracking is the reliable identification of inherent points with distinct tissue features on each projection image and their association between two images. The identification of the feature points on a planar x-ray image is realized by searching for points with high intensity gradient. The feature points are associated by using the scale invariance features transform descriptor. The performance of the proposed technique is evaluated by using images of a motion phantom and four archived clinical cases acquired using either a CyberKnife equipped with a stereoscopic x-ray imaging system, or a LINAC equipped with an onboard kV imager and an electronic portal imaging device. In the phantom study, the results obtained using the proposed method agree with the measurements to within 2 mm in all three directions. In the clinical study, the mean error is 0.48 ± 0.46 mm for four patient data with 144 sequential images. In this work, a tissue feature-based tracking method for stereoscopic x-ray image guided radiation therapy is developed. The technique avoids the invasive procedure of fiducial implantation and may greatly facilitate the clinical workflow.

  20. Preparation of factor VII concentrate using CNBr-activated Sepharose 4B immunoaffinity chromatography

    PubMed Central

    Mousavi Hosseini, Kamran; Nasiri, Saleh

    2015-01-01

    Background: Factor VII concentrates are used in patients with congenital or acquired factor VII deficiency or treatment of hemophilia patients with inhibitors. In this research, immunoaffinity chromatography was used to purify factor VII from prothrombin complex (Prothrombin- Proconvertin-Stuart Factor-Antihemophilic Factor B or PPSB) which contains coagulation factors II, VII, IX and X. The aim of this study was to improve purity, safety and tolerability as a highly purified factor VII concentrate. Methods: PPSB was prepared using DEAE-Sephadex and was used as the starting material for purification of coagulation factor VII. Prothrombin complex was treated by solvent/detergent at 24°C for 6 h with constant stirring. The mixture of PPSB in the PBS buffer was filtered and then chromatographed using CNBr-activated Sepharose 4B coupled with specific antibody. Factors II, IX, VII, X and VIIa were assayed on the fractions. Fractions of 48-50 were pooled and lyophilized as a factor VII concentrate. Agarose gel electrophoresis was performed and Tween 80 was measured in the factor VII concentrate. Results: Specific activity of factor VII concentrate increased from 0.16 to 55.6 with a purificationfold of 347.5 and the amount of activated factor VII (FVIIa) was found higher than PPSB (4.4-fold). Results of electrophoresis on agarose gel indicated higher purity of Factor VII compared to PPSB; these finding revealed that factor VII migrated as alpha-2 proteins. In order to improve viral safety, solvent-detergent treatment was applied prior to further purification and nearly complete elimination of tween 80 (2 μg/ml). Conclusion: It was concluded that immuonoaffinity chromatography using CNBr-activated Sepharose 4B can be a suitable choice for large-scale production of factor VII concentrate with higher purity, safety and activated factor VII. PMID:26034723

  1. Preparation of factor VII concentrate using CNBr-activated Sepharose 4B immunoaffinity chromatography.

    PubMed

    Mousavi Hosseini, Kamran; Nasiri, Saleh

    2015-01-01

    Factor VII concentrates are used in patients with congenital or acquired factor VII deficiency or treatment of hemophilia patients with inhibitors. In this research, immunoaffinity chromatography was used to purify factor VII from prothrombin complex (Prothrombin- Proconvertin-Stuart Factor-Antihemophilic Factor B or PPSB) which contains coagulation factors II, VII, IX and X. The aim of this study was to improve purity, safety and tolerability as a highly purified factor VII concentrate. PPSB was prepared using DEAE-Sephadex and was used as the starting material for purification of coagulation factor VII. Prothrombin complex was treated by solvent/detergent at 24°C for 6 h with constant stirring. The mixture of PPSB in the PBS buffer was filtered and then chromatographed using CNBr-activated Sepharose 4B coupled with specific antibody. Factors II, IX, VII, X and VIIa were assayed on the fractions. Fractions of 48-50 were pooled and lyophilized as a factor VII concentrate. Agarose gel electrophoresis was performed and Tween 80 was measured in the factor VII concentrate. Specific activity of factor VII concentrate increased from 0.16 to 55.6 with a purificationfold of 347.5 and the amount of activated factor VII (FVIIa) was found higher than PPSB (4.4-fold). RESULTS of electrophoresis on agarose gel indicated higher purity of Factor VII compared to PPSB; these finding revealed that factor VII migrated as alpha-2 proteins. In order to improve viral safety, solvent-detergent treatment was applied prior to further purification and nearly complete elimination of tween 80 (2 μg/ml). It was concluded that immuonoaffinity chromatography using CNBr-activated Sepharose 4B can be a suitable choice for large-scale production of factor VII concentrate with higher purity, safety and activated factor VII.

  2. Pathogenesis of mitral valve disease in mucopolysaccharidosis VII dogs.

    PubMed

    Bigg, Paul W; Baldo, Guilherme; Sleeper, Meg M; O'Donnell, Patricia A; Bai, Hanqing; Rokkam, Venkata R P; Liu, Yuli; Wu, Susan; Giugliani, Roberto; Casal, Margret L; Haskins, Mark E; Ponder, Katherine P

    2013-11-01

    Mucopolysaccharidosis VII (MPS VII) is due to the deficient activity of β-glucuronidase (GUSB) and results in the accumulation of glycosaminoglycans (GAGs) in lysosomes and multisystemic disease with cardiovascular manifestations. The goal here was to determine the pathogenesis of mitral valve (MV) disease in MPS VII dogs. Untreated MPS VII dogs had a marked reduction in the histochemical signal for structurally-intact collagen in the MV at 6 months of age, when mitral regurgitation had developed. Electron microscopy demonstrated that collagen fibrils were of normal diameter, but failed to align into large parallel arrays. mRNA analysis demonstrated a modest reduction in the expression of genes that encode collagen or collagen-associated proteins such as the proteoglycan decorin which helps collagen fibrils assemble, and a marked increase for genes that encode proteases such as cathepsins. Indeed, enzyme activity for cathepsin B (CtsB) was 19-fold normal. MPS VII dogs that received neonatal intravenous injection of a gamma retroviral vector had an improved signal for structurally-intact collagen, and reduced CtsB activity relative to that seen in untreated MPS VII dogs. We conclude that MR in untreated MPS VII dogs was likely due to abnormalities in MV collagen structure. This could be due to upregulation of enzymes that degrade collagen or collagen-associated proteins, to the accumulation of GAGs that compete with proteoglycans such as decorin for binding to collagen, or to other causes. Further delineation of the etiology of abnormal collagen structure may lead to treatments that improve biomechanical properties of the MV and other tissues. © 2013.

  3. Pathogenesis of Mitral Valve Disease in Mucopolysaccharidosis VII Dogs

    PubMed Central

    Bigg, Paul W.; Baldo, Guilherme; Sleeper, Meg M.; O'Donnell, Patricia A.; Bai, Hanqing; Rokkam, Venkata R.P.; Liu, Yuli; Wu, Susan; Giugliani, Roberto; Casal, Margret L.; Haskins, Mark E.; Ponder, Katherine P.

    2013-01-01

    Mucopolysaccharidosis VII (MPS VII) is due to deficient activity of β-glucuronidase (GUSB) and results in the accumulation of glycosaminoglycans (GAGs) in lysosomes and multisystemic disease with cardiavascular manifestations. The goal here was to determine the pathogenesis of mitral valve (MV) disease in MPS VII dogs. Untreated MPS VII dogs had a marked reduction in the histochemical signal for structurally-intact collagen in the MV at 6 months of age, when mitral regurgitation had developed. Electron microscopy demonstrated that collagen fibrils were of normal diameter, but failed to align into large parallel arrays. mRNA analysis demonstrated a modest reduction in the expression of genes that encode collagen or collagen-associated proteins such as the proteoglycan decorin which helps collagen fibrils assemble, and a marked increase for genes that encode proteases such as cathepsins. Indeed, enzyme activity for cathepsin B (CtsB) was 19-fold normal. MPS VII dogs that received neonatal intravenous injection of a gamma retroviral vector had an improved signal for structurally-intact collagen, and reduced CtsB activity relative to that seen in untreated MPS VII dogs. We conclude that MR in untreated MPS VII dogs was likely due to abnormalities in MV collagen structure. This could be due to upregulation of enzymes that degrade collagen or collagen-associated proteins, to the accumulation of GAGs that compete with proteoglycans such as decorin for binding to collagen, or to other causes. Further delineation of the etiology of abnormal collagen structure may lead to treatments that improve biomechanical properties of the MV and other tissues. PMID:23856419

  4. Is prophylaxis required for delivery in women with factor VII deficiency?

    PubMed Central

    Baumann Kreuziger, Lisa M.; Morton, Colleen T.; Reding, Mark T.

    2013-01-01

    Introduction Factor VII (fVII) deficiency is a rare congenital bleeding disorder in which fVII activity level and bleeding tendency do not completely correlate. Pregnancy and delivery present a significant hemostatic challenge to women with fVII deficiency. Treatment with recombinant factor VIIa (rfVIIa) carries a thrombotic risk and the literature is unclear whether prophylaxis is necessary prior to delivery. Aim To define management, hemorrhagic and thrombotic complications of pregnant women with fVII deficiency through a systematic review. Methods Medical databases (PubMed, MEDLINE, CINAHL, Academic Search Premier, Cochrane Library, Web of Science and Scopus) were searched using “factor VII deficiency” and “pregnancy” or “surgery.” Overall 34 articles, 4 abstracts, and 3 institutional cases were reviewed. Results Literature from 1953–2011 reported 94 live births from 62 women with fVII deficiency. The median fVII activity was 5.5%. Hemostatic prophylaxis was used in 32% of deliveries. Without prophylaxis, 40 vaginal deliveries and 16 cesarean sections were completed. The odds of receiving prophylaxis were 2.9 times higher in women undergoing cesarean section compared to vaginal delivery. Post-partum hemorrhage occurred in 10% of deliveries with prophylaxis and 13% of deliveries without prophylaxis. The fVII level did not significantly differ between women who did and did not receive prophylaxis. Conclusion We present the only systematic review of the management of pregnancy in fVII deficient women. No difference in post-partum hemorrhage was seen in deliveries with and without prophylaxis. Therefore we recommend that rfVIIa be available in the case of hemorrhage or surgical intervention, but not as mandatory prophylaxis. PMID:23607277

  5. Is prophylaxis required for delivery in women with factor VII deficiency?

    PubMed

    Baumann Kreuziger, L M; Morton, Colleen T; Reding, Mark T

    2013-11-01

    Factor VII (fVII) deficiency is a rare congenital bleeding disorder in which fVII activity level and bleeding tendency do not completely correlate. Pregnancy and delivery present a significant haemostatic challenge to women with fVII deficiency. Treatment with recombinant factor VIIa (rfVIIa) carries a thrombotic risk and the literature is not clear whether prophylaxis is necessary prior to delivery. The aim of this study was to define management, haemorrhagic and thrombotic complications of pregnant women with fVII deficiency through a systematic review. Medical databases (PubMed, MEDLINE, CINAHL, Academic Search Premier, Cochrane Library, Web of Science and Scopus) were searched using "factor VII deficiency" and "pregnancy" or "surgery." Overall 34 articles, four abstracts, and three institutional cases were reviewed. Literature from 1953 to 2011 reported 94 live births from 62 women with fVII deficiency. The median fVII activity was 5.5%. Haemostatic prophylaxis was used in 32% of deliveries. Without prophylaxis, 40 vaginal deliveries and 16 caesarean sections were completed. The odds of receiving prophylaxis were 2.9 times higher in women undergoing caesarean section compared to vaginal delivery. Post-partum haemorrhage occurred in 10% of deliveries with prophylaxis and 13% of deliveries without prophylaxis. The fVII level did not significantly differ between women who did and did not receive prophylaxis. We present the only systematic review of the management of pregnancy in fVII deficient women. No difference in post-partum haemorrhage was seen in deliveries with and without prophylaxis. Therefore, we recommend that rfVIIa be available in the case of haemorrhage or surgical intervention, but not as mandatory prophylaxis. © 2013 John Wiley & Sons Ltd.

  6. Doing Textiles Experiments in Game-Based Virtual Reality: A Design of the Stereoscopic Chemical Laboratory (SCL) for Textiles Education

    ERIC Educational Resources Information Center

    Lau, Kung Wong; Kan, Chi Wai; Lee, Pui Yuen

    2017-01-01

    Purpose: The purpose of this paper is to discuss the use of stereoscopic virtual technology in textile and fashion studies in particular to the area of chemical experiment. The development of a designed virtual platform, called Stereoscopic Chemical Laboratory (SCL), is introduced. Design/methodology/approach: To implement the suggested…

  7. Matching and correlation computations in stereoscopic depth perception.

    PubMed

    Doi, Takahiro; Tanabe, Seiji; Fujita, Ichiro

    2011-03-02

    A fundamental task of the visual system is to infer depth by using binocular disparity. To encode binocular disparity, the visual cortex performs two distinct computations: one detects matched patterns in paired images (matching computation); the other constructs the cross-correlation between the images (correlation computation). How the two computations are used in stereoscopic perception is unclear. We dissociated their contributions in near/far discrimination by varying the magnitude of the disparity across separate sessions. For small disparity (0.03°), subjects performed at chance level to a binocularly opposite-contrast (anti-correlated) random-dot stereogram (RDS) but improved their performance with the proportion of contrast-matched (correlated) dots. For large disparity (0.48°), the direction of perceived depth reversed with an anti-correlated RDS relative to that for a correlated one. Neither reversed nor normal depth was perceived when anti-correlation was applied to half of the dots. We explain the decision process as a weighted average of the two computations, with the relative weight of the correlation computation increasing with the disparity magnitude. We conclude that matching computation dominates fine depth perception, while both computations contribute to coarser depth perception. Thus, stereoscopic depth perception recruits different computations depending on the disparity magnitude.

  8. Perceptual asymmetry reveals neural substrates underlying stereoscopic transparency.

    PubMed

    Tsirlin, Inna; Allison, Robert S; Wilcox, Laurie M

    2012-02-01

    We describe a perceptual asymmetry found in stereoscopic perception of overlaid random-dot surfaces. Specifically, the minimum separation in depth needed to perceptually segregate two overlaid surfaces depended on the distribution of dots across the surfaces. With the total dot density fixed, significantly larger inter-plane disparities were required for perceptual segregation of the surfaces when the front surface had fewer dots than the back surface compared to when the back surface was the one with fewer dots. We propose that our results reflect an asymmetry in the signal strength of the front and back surfaces due to the assignment of the spaces between the dots to the back surface by disparity interpolation. This hypothesis was supported by the results of two experiments designed to reduce the imbalance in the neuronal response to the two surfaces. We modeled the psychophysical data with a network of inter-neural connections: excitatory within-disparity and inhibitory across disparity, where the spread of disparity was modulated according to figure-ground assignment. These psychophysical and computational findings suggest that stereoscopic transparency depends on both inter-neural interactions of disparity-tuned cells and higher-level processes governing figure ground segregation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Digital stereoscopic cinema: the 21st century

    NASA Astrophysics Data System (ADS)

    Lipton, Lenny

    2008-02-01

    Over 1000 theaters in more than a dozen countries have been outfitted with digital projectors using the Texas Instruments DLP engine equipped to show field-sequential 3-D movies using the polarized method of image selection. Shuttering eyewear and advanced anaglyph products are also being deployed for image selection. Many studios are in production with stereoscopic films, and some have committed to producing their entire output of animated features in 3-D. This is a time of technology change for the motion picture industry.

  10. Using a high-definition stereoscopic video system to teach microscopic surgery

    NASA Astrophysics Data System (ADS)

    Ilgner, Justus; Park, Jonas Jae-Hyun; Labbé, Daniel; Westhofen, Martin

    2007-02-01

    Introduction: While there is an increasing demand for minimally invasive operative techniques in Ear, Nose and Throat surgery, these operations are difficult to learn for junior doctors and demanding to supervise for experienced surgeons. The motivation for this study was to integrate high-definition (HD) stereoscopic video monitoring in microscopic surgery in order to facilitate teaching interaction between senior and junior surgeon. Material and methods: We attached a 1280x1024 HD stereo camera (TrueVisionSystems TM Inc., Santa Barbara, CA, USA) to an operating microscope (Zeiss ProMagis, Zeiss Co., Oberkochen, Germany), whose images were processed online by a PC workstation consisting of a dual Intel® Xeon® CPU (Intel Co., Santa Clara, CA). The live image was displayed by two LCD projectors @ 1280x768 pixels on a 1,25m rear-projection screen by polarized filters. While the junior surgeon performed the surgical procedure based on the displayed stereoscopic image, all other participants (senior surgeon, nurse and medical students) shared the same stereoscopic image from the screen. Results: With the basic setup being performed only once on the day before surgery, fine adjustments required about 10 minutes extra during the operation schedule, which fitted into the time interval between patients and thus did not prolong operation times. As all relevant features of the operative field were demonstrated on one large screen, four major effects were obtained: A) Stereoscopy facilitated orientation for the junior surgeon as well as for medical students. B) The stereoscopic image served as an unequivocal guide for the senior surgeon to demonstrate the next surgical steps to the junior colleague. C) The theatre nurse shared the same image, anticipating the next instruments which were needed. D) Medical students instantly share the information given by all staff and the image, thus avoiding the need for an extra teaching session. Conclusion: High definition

  11. Age-related changes in factor VII proteolysis in vivo.

    PubMed

    Ofosu, F A; Craven, S; Dewar, L; Anvari, N; Andrew, M; Blajchman, M A

    1996-08-01

    Previous studies have reported that pre-operative plasmas of patients over the age of 40 years who developed post-operative deep vein thrombosis (DVT) had approximately twice the amount of proteolysed factor VII found in plasmas of patients in whom prophylaxis with heparin or low M(r) heparin was successful. These and other studies also reported higher concentrations of thrombin-antithrombin III in pre- and post-operative plasmas of patients who developed post-operative thrombosis than in plasmas of patients in whom prophylaxis was successful. Whether the extent of factor VII proteolysis seen in the patients who developed post-operative DVT is related to the severity of their disease or age is not known. This report investigated age-related changes in the concentrations of total factor VII protein, factor VII zymogen, factor VIIa, tissue factor pathway inhibitor, thrombin-antithrombin III, and prothrombin fragment 1 + 2 in normal plasmas and the relationships between these parameters. With the exception of thrombin-antithrombin III, statistically significant increases in the concentrations of these parameters with age were found. Additionally, the differences between the concentrations of total factor VII protein and factor VII zymogen, an index factor VII proteolysis in vivo, were statistically significant only for individuals over age 40. Using linear regression analysis, a significant correlation was found to exist between the concentrations of plasma factor VIIa and prothrombin fragment 1 + 2. Since factor VIIa-tissue factor probably initiates coagulation in vivo, we hypothesize that the elevated plasma factor VIIa (reflecting a less tightly regulated tissue factor activity and therefore increased thrombin production in vivo) accounts for the high risk for post-operative thrombosis seen in individuals over the age of 40.

  12. Disparity profiles in 3DV applications: overcoming the issue of heterogeneous viewing conditions in stereoscopic delivery

    NASA Astrophysics Data System (ADS)

    Boisson, Guillaume; Chamaret, Christel

    2012-03-01

    More and more numerous 3D movies are released each year. Thanks to the current spread of 3D-TV displays, these 3D Video (3DV) contents are about to enter massively the homes. Yet viewing conditions determine the stereoscopic features achievable for 3DV material. Because the conditions at home - screen size and distance to screen - differ significantly from a theater, 3D Cinema movies need to be repurposed before broadcast and replication on 3D Blu-ray Discs for being fully enjoyed at home. In that paper we tackle that particular issue of how to handle the variety of viewing conditions in stereoscopic contents delivery. To that extend we first investigate what is basically at stake for granting stereoscopic viewers' comfort, through the well-known - and sometimes dispraised - vergence-accommodation conflict. Thereby we define a set of basic rules that can serve as guidelines for 3DV creation. We propose disparity profiles as new requirements for 3DV production and repurposing. Meeting proposed background and foreground constraints prevents from visual fatigue, and occupying the whole depth budget available grants optimal 3D effects. We present an efficient algorithm for automatic disparity-based 3DV retargeting depending on the viewing conditions. Variants are proposed depending on the input format (stereoscopic binocular content or depth-based format) and the level of complexity achievable.

  13. The effects of 5.1 sound presentations on the perception of stereoscopic imagery in video games

    NASA Astrophysics Data System (ADS)

    Cullen, Brian; Galperin, Daniel; Collins, Karen; Hogue, Andrew; Kapralos, Bill

    2013-03-01

    Stereoscopic 3D (S3D) content in games, film and other audio-visual media has been steadily increasing over the past number of years. However, there are still open, fundamental questions regarding its implementation, particularly as it relates to a multi-modal experience that involves sound and haptics. Research has shown that sound has considerable impact on our perception of 2D phenomena, but very little research has considered how sound may influence stereoscopic 3D. Here we present the results of an experiment that examined the effects of 5.1 surround sound (5.1) and stereo loudspeaker setups on depth perception in relation to S3D imagery within a video game environment. Our aim was to answer the question: "can 5.1 surround sound enhance the participant's perception of depth in the stereoscopic field when compared to traditional stereo sound presentations?" In addition, our study examined how the presence or absence of Doppler frequency shift and frequency fall-off audio effects can also influence depth judgment under these conditions. Results suggest that 5.1 surround sound presentations enhance the apparent depth of stereoscopic imagery when compared to stereo presentations. Results also suggest that the addition of audio effects such as Doppler shift and frequency fall-off filters can influence the apparent depth of S3D objects.

  14. Visual perception and stereoscopic imaging: an artist's perspective

    NASA Astrophysics Data System (ADS)

    Mason, Steve

    2015-03-01

    This paper continues my 2014 February IS and T/SPIE Convention exploration into the relationship of stereoscopic vision and consciousness (90141F-1). It was proposed then that by using stereoscopic imaging people may consciously experience, or see, what they are viewing and thereby help make them more aware of the way their brains manage and interpret visual information. Environmental imaging was suggested as a way to accomplish this. This paper is the result of further investigation, research, and follow-up imaging. A show of images, that is a result of this research, allows viewers to experience for themselves the effects of stereoscopy on consciousness. Creating dye-infused aluminum prints while employing ChromaDepth® 3D glasses, I hope to not only raise awareness of visual processing but also explore the differences and similarities between the artist and scientist―art increases right brain spatial consciousness, not only empirical thinking, while furthering the viewer's cognizance of the process of seeing. The artist must abandon preconceptions and expectations, despite what the evidence and experience may indicate in order to see what is happening in his work and to allow it to develop in ways he/she could never anticipate. This process is then revealed to the viewer in a show of work. It is in the experiencing, not just from the thinking, where insight is achieved. Directing the viewer's awareness during the experience using stereoscopic imaging allows for further understanding of the brain's function in the visual process. A cognitive transformation occurs, the preverbal "left/right brain shift," in order for viewers to "see" the space. Using what we know from recent brain research, these images will draw from certain parts of the brain when viewed in two dimensions and different ones when viewed stereoscopically, a shift, if one is looking for it, which is quite noticeable. People who have experienced these images in the context of examining their own

  15. Case study: the introduction of stereoscopic games on the Sony PlayStation 3

    NASA Astrophysics Data System (ADS)

    Bickerstaff, Ian

    2012-03-01

    A free stereoscopic firmware update on Sony Computer Entertainment's PlayStation® 3 console provides the potential to increase enormously the popularity of stereoscopic 3D in the home. For this to succeed though, a large selection of content has to become available that exploits 3D in the best way possible. In addition to the existing challenges found in creating 3D movies and television programmes, the stereography must compensate for the dynamic and unpredictable environments found in games. Automatically, the software must map the depth range of the scene into the display's comfort zone, while minimising depth compression. This paper presents a range of techniques developed to solve this problem and the challenge of creating twice as many images as the 2D version without excessively compromising the frame rate or image quality. At the time of writing, over 80 stereoscopic PlayStation 3 games have been released and notable titles are used as examples to illustrate how the techniques have been adapted for different game genres. Since the firmware's introduction in 2010, the industry has matured with a large number of developers now producing increasingly sophisticated 3D content. New technologies such as viewer head tracking and head-mounted displays should increase the appeal of 3D in the home still further.

  16. Using Saliency-Weighted Disparity Statistics for Objective Visual Comfort Assessment of Stereoscopic Images

    NASA Astrophysics Data System (ADS)

    Zhang, Wenlan; Luo, Ting; Jiang, Gangyi; Jiang, Qiuping; Ying, Hongwei; Lu, Jing

    2016-06-01

    Visual comfort assessment (VCA) for stereoscopic images is a particularly significant yet challenging task in 3D quality of experience research field. Although the subjective assessment given by human observers is known as the most reliable way to evaluate the experienced visual discomfort, it is time-consuming and non-systematic. Therefore, it is of great importance to develop objective VCA approaches that can faithfully predict the degree of visual discomfort as human beings do. In this paper, a novel two-stage objective VCA framework is proposed. The main contribution of this study is that the important visual attention mechanism of human visual system is incorporated for visual comfort-aware feature extraction. Specifically, in the first stage, we first construct an adaptive 3D visual saliency detection model to derive saliency map of a stereoscopic image, and then a set of saliency-weighted disparity statistics are computed and combined to form a single feature vector to represent a stereoscopic image in terms of visual comfort. In the second stage, a high dimensional feature vector is fused into a single visual comfort score by performing random forest algorithm. Experimental results on two benchmark databases confirm the superior performance of the proposed approach.

  17. Instability of the perceived world while watching 3D stereoscopic imagery: A likely source of motion sickness symptoms

    PubMed Central

    Hwang, Alex D.; Peli, Eli

    2014-01-01

    Watching 3D content using a stereoscopic display may cause various discomforting symptoms, including eye strain, blurred vision, double vision, and motion sickness. Numerous studies have reported motion-sickness-like symptoms during stereoscopic viewing, but no causal linkage between specific aspects of the presentation and the induced discomfort has been explicitly proposed. Here, we describe several causes, in which stereoscopic capture, display, and viewing differ from natural viewing resulting in static and, importantly, dynamic distortions that conflict with the expected stability and rigidity of the real world. This analysis provides a basis for suggested changes to display systems that may alleviate the symptoms, and suggestions for future studies to determine the relative contribution of the various effects to the unpleasant symptoms. PMID:26034562

  18. Evaluation of stereoscopic display with visual function and interview

    NASA Astrophysics Data System (ADS)

    Okuyama, Fumio

    1999-05-01

    The influence of binocular stereoscopic (3D) television display on the human eye were compared with one of a 2D display, using human visual function testing and interviews. A 40- inch double lenticular display was used for 2D/3D comparison experiments. Subjects observed the display for 30 minutes at a distance 1.0 m, with a combination of 2D material and one of 3D material. The participants were twelve young adults. Main optometric test with visual function measured were visual acuity, refraction, phoria, near vision point, accommodation etc. The interview consisted of 17 questions. Testing procedures were performed just before watching, just after watching, and forty-five minutes after watching. Changes in visual function are characterized as prolongation of near vision point, decrease of accommodation and increase in phoria. 3D viewing interview results show much more visual fatigue in comparison with 2D results. The conclusions are: 1) change in visual function is larger and visual fatigue is more intense when viewing 3D images. 2) The evaluation method with visual function and interview proved to be very satisfactory for analyzing the influence of stereoscopic display on human eye.

  19. Portable low-cost devices for videotaping, editing, and displaying field-sequential stereoscopic motion pictures and video

    NASA Astrophysics Data System (ADS)

    Starks, Michael R.

    1990-09-01

    A variety of low cost devices for capturing, editing and displaying field sequential 60 cycle stereoscopic video have recently been marketed by 3D TV Corp. and others. When properly used, they give very high quality images with most consumer and professional equipment. Our stereoscopic multiplexers for creating and editing field sequential video in NTSC or component(SVHS, Betacain, RGB) and Home 3D Theater system employing LCD eyeglasses have made 3D movies and television available to a large audience.

  20. 32 CFR 2003.7 - Support Staff (Article VII).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 6 2014-07-01 2014-07-01 false Support Staff (Article VII). 2003.7 Section 2003... (ISCAP) BYLAWS, RULES, AND APPEAL PROCEDURES Bylaws § 2003.7 Support Staff (Article VII). The staff of..., provides program and administrative support for the Panel. The Executive Secretary supervises the staff in...

  1. 32 CFR 2003.7 - Support Staff (Article VII).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Support Staff (Article VII). 2003.7 Section 2003... (ISCAP) BYLAWS, RULES, AND APPEAL PROCEDURES Bylaws § 2003.7 Support Staff (Article VII). The staff of..., provides program and administrative support for the Panel. The Executive Secretary supervises the staff in...

  2. Acquired factor VII deficiency associated with acute myeloid leukemia.

    PubMed

    Anoun, Soumaya; Lamchahab, Mouna; Oukkache, Bouchra; Qachouh, Maryam; Benchekroun, Said; Quessar, Asmaa

    2015-04-01

    Isolated acquired factor VII deficiency is a rare coagulopathy. It has been reported in 31 patients with malignancy, sepsis, postoperatively, aplastic anemia, and during bone marrow transplantation. We discuss, through a new case of acquired factor VII deficiency, the characteristics of this disease when it is associated with acute myeloid leukemia. Acquired factor VII deficiency in hematological diseases can be caused by intensive chemotherapy, infections, or hepatic dysfunction. The best treatment in developing countries remains corticosteroids associated with plasma exchange, frozen plasma, and antibiotics.

  3. Current status of stereoscopic 3D LCD TV technologies

    NASA Astrophysics Data System (ADS)

    Choi, Hee-Jin

    2011-06-01

    The year 2010 may be recorded as a first year of successful commercial 3D products. Among them, the 3D LCD TVs are expected to be the major one regarding the sales volume. In this paper, the principle of current stereoscopic 3D LCD TV techniques and the required flat panel display (FPD) technologies for the realization of them are reviewed. [Figure not available: see fulltext.

  4. A dataset of stereoscopic images and ground-truth disparity mimicking human fixations in peripersonal space

    PubMed Central

    Canessa, Andrea; Gibaldi, Agostino; Chessa, Manuela; Fato, Marco; Solari, Fabio; Sabatini, Silvio P.

    2017-01-01

    Binocular stereopsis is the ability of a visual system, belonging to a live being or a machine, to interpret the different visual information deriving from two eyes/cameras for depth perception. From this perspective, the ground-truth information about three-dimensional visual space, which is hardly available, is an ideal tool both for evaluating human performance and for benchmarking machine vision algorithms. In the present work, we implemented a rendering methodology in which the camera pose mimics realistic eye pose for a fixating observer, thus including convergent eye geometry and cyclotorsion. The virtual environment we developed relies on highly accurate 3D virtual models, and its full controllability allows us to obtain the stereoscopic pairs together with the ground-truth depth and camera pose information. We thus created a stereoscopic dataset: GENUA PESTO—GENoa hUman Active fixation database: PEripersonal space STereoscopic images and grOund truth disparity. The dataset aims to provide a unified framework useful for a number of problems relevant to human and computer vision, from scene exploration and eye movement studies to 3D scene reconstruction. PMID:28350382

  5. Gene therapy ameliorates cardiovascular disease in dogs with mucopolysaccharidosis VII.

    PubMed

    Sleeper, M M; Fornasari, B; Ellinwood, N M; Weil, M A; Melniczek, J; O'Malley, T M; Sammarco, C D; Xu, L; Ponder, K P; Haskins, M E

    2004-08-17

    Mucopolysaccharidosis VII (MPS VII) is a lysosomal storage disease caused by deficient beta-glucuronidase (GUSB) activity resulting in defective catabolism of glycosaminoglycans (GAGs). Cardiac disease is a major cause of death in MPS VII because of accumulation of GAGs in cardiovascular cells. Manifestations include cardiomyopathy, mitral and aortic valve thickening, and aortic root dilation and may cause death in the early months of life or may be compatible with a fairly normal lifespan. We previously reported that neonatal administration of a retroviral vector (RV) resulted in transduction of hepatocytes, which secreted GUSB into the blood and could be taken up by cells throughout the body. The goal of this study was to evaluate the effect on cardiac disease. Six MPS VII dogs were treated intravenously with an RV-expressing canine GUSB. Echocardiographic parameters, cardiovascular lesions, and biochemical parameters of these dogs were compared with those of normal and untreated MPS VII dogs. RV-treated dogs were markedly improved compared with untreated MPS VII dogs. Most RV-treated MPS VII dogs had mild or moderate mitral regurgitation at 4 to 5 months after birth, which improved or disappeared when evaluated at 9 to 11 and at 24 months. Similarly, mitral valve thickening present early in some animals disappeared over time, whereas aortic dilation and aortic valve thickening were absent at all times. Both myocardium and aorta had significant levels of GUSB and reduction in GAGs.

  6. [Coagulation factor VII levels in uremic patients and theirs influence factors].

    PubMed

    Fang, Jun; Xia, Ling-Hui; Wei, Wen-Ning; Song, Shan-Jun

    2004-12-01

    This study was aimed to investigate coagulation factor VII level in uremic patients with chronic renal failure and to explore theirs influence factors. The plasma levels of coagulation factor VII were detected in 30 uremic patients with chronic renal failure before and after hemodialysis for 1 month, the factor VII activity (FVII:C) was determined by one-stage coagulation method, while activated factor VII (FVIIa) was measured by one-stage coagulation method using recombinant soluble tissue factor, and factor VII antigen was detected by ELISA. The results showed that: (1) The FVIIa, FVII:C and FVIIAg levels in chronic uremic patients before hemodialysis were 4.00 +/- 0.86 microg/L, (148.5 +/- 40.4)% and (99.8 +/- 21.1)% respectively, which were significantly increased, as compared with healthy controls [2.77 +/- 1.02 microg/L, (113.1 +/- 33.0)% and (73.7 +/- 18.3)% respectively, P < 0.05]. (2) After hemodialysis the FVIIa, FVII:C and FVIIAg levels in uremic patients significantly enhanced to 5.56 +/- 1.45 microg/L, (200.8 +/- 68.7)% and (124.1 +/- 19.3)% respectively (P < 0.05). (3) The abnormal increase of coagulation factor VII was positively correlated with levels of blood uria nitrogen and serum creatinine before hemodialysis but not after hemodialysis. It is concluded that the enhanced levels of coagulation factor VII in chronic uremic patients suggested abnormal activated state, herperactivity and elevated production of factor VII which correlated with renal functional injury. The abnormality of factor VII in uremia may be aggravated by hemodialysis. Coagulation factor (FVII) may be a risk factor for cardiovascular events in uremic patients who especially had been accepted long-term hemodialysis.

  7. Blood glucose may condition factor VII levels in diabetic and normal subjects.

    PubMed

    Ceriello, A; Giugliano, D; Quatraro, A; Dello Russo, P; Torella, R

    1988-12-01

    Increased factor VII levels have been reported in Type 1 (insulin-dependent) diabetic subjects. A direct correlation between fasting plasma glucose and factor VII level was found to exist in both diabetic and normal subjects. Induced-hyperglycaemia was able to increase factor VII levels in both diabetic patients and normal control subjects while, when euglycaemia was achieved in diabetic patients, factor VII values returned to normal range. This study shows that the level of factor VII may be directly conditioned by circulating blood glucose and, therefore, stresses the role of hyperglycaemia in conditioning coagulation abnormalities in diabetes mellitus.

  8. An MR-compatible stereoscopic in-room 3D display for MR-guided interventions.

    PubMed

    Brunner, Alexander; Groebner, Jens; Umathum, Reiner; Maier, Florian; Semmler, Wolfhard; Bock, Michael

    2014-08-01

    A commercial three-dimensional (3D) monitor was modified for use inside the scanner room to provide stereoscopic real-time visualization during magnetic resonance (MR)-guided interventions, and tested in a catheter-tracking phantom experiment at 1.5 T. Brightness, uniformity, radio frequency (RF) emissions and MR image interferences were measured. Due to modifications, the center luminance of the 3D monitor was reduced by 14%, and the addition of a Faraday shield further reduced the remaining luminance by 31%. RF emissions could be effectively shielded; only a minor signal-to-noise ratio (SNR) decrease of 4.6% was observed during imaging. During the tracking experiment, the 3D orientation of the catheter and vessel structures in the phantom could be visualized stereoscopically.

  9. Fusion Prevents the Redundant Signals Effect: Evidence from Stereoscopically Presented Stimuli

    ERIC Educational Resources Information Center

    Schroter, Hannes; Fiedler, Anja; Miller, Jeff; Ulrich, Rolf

    2011-01-01

    In a simple reaction time (RT) experiment, visual stimuli were stereoscopically presented either to one eye (single stimulation) or to both eyes (redundant stimulation), with brightness matched for single and redundant stimulations. Redundant stimulation resulted in two separate percepts when noncorresponding retinal areas were stimulated, whereas…

  10. Stereoscopic display technologies, interaction paradigms, and rendering approaches for neurosurgical visualization

    NASA Astrophysics Data System (ADS)

    Cooperstock, Jeremy R.; Wang, Guangyu

    2009-02-01

    We conducted a comparative study of different stereoscopic display modalities (head-mounted display, polarized projection, and multiview lenticular display) to evaluate their efficacy in supporting manipulation and understanding of 3D content, specifically, in the context of neurosurgical visualization. Our study was intended to quantify the differences in resulting task performance between these choices of display technology. The experimental configuration involved a segmented brain vasculature and a simulated tumor. Subjects were asked to manipulate the vasculature and a pen-like virtual probe in order to define a vessel-free path from cortical surface to the targeted tumor. Because of the anatomical complexity, defining such a path can be a challenging task. To evaluate the system, we quantified performance differences under three different stereoscopic viewing conditions. Our results indicate that, on average, participants achieved best performance using polarized projection, and worst with the multiview lenticular display. These quantitative measurements were further reinforced by the subjects' responses to our post-test questionnaire regarding personal preferences.

  11. Stereoscopic Analysis of 19 May and 31 Aug 2007 Filament Eruptions

    NASA Technical Reports Server (NTRS)

    Liewer, Paulett; DeJong, E. M.; Hall, J. R.

    2008-01-01

    The presentation outline includes results from stereoscopic analysis of SECCHI/EUVI data for 19 May 2007 filament eruption, including the determined 3D trajectory of erupting filament, strong evidence for reconnection below erupting filament as consistent with standard model, and comparison of EUVI and H-alpha images during eruption; and results from stereoscopic analytic of 21 August 2007 filament eruption. Slide topics include standard model of filament eruption; 2007 May 19 STEREO A/SECCHI/EUVI 195 and 304 A: CME signatures and filament eruption, 3D reconstruction of erupting prominence; filament's relation to coronal magnetic fields; 3d reconstructions of filament eruption; height-time plot of eruption from 3D reconstructions; detailed pre-eruptions comparison of H-alpha and EUVI 304 at 12:42 UT; comparisons during the eruption; STEREO prominence and CME August 31, 2007; reconstructions of prominence and leading edges of both dark cavity and CME; and 3D reconstructions of prominence and leading edges.

  12. Factor VII Deficiency: Clinical Phenotype, Genotype and Therapy.

    PubMed

    Napolitano, Mariasanta; Siragusa, Sergio; Mariani, Guglielmo

    2017-03-28

    Factor VII deficiency is the most common among rare inherited autosomal recessive bleeding disorders, and is a chameleon disease due to the lack of a direct correlation between plasma levels of coagulation Factor VII and bleeding manifestations. Clinical phenotypes range from asymptomatic condition-even in homozygous subjects-to severe life-threatening bleedings (central nervous system, gastrointestinal bleeding). Prediction of bleeding risk is thus based on multiple parameters that challenge disease management. Spontaneous or surgical bleedings require accurate treatment schedules, and patients at high risk of severe hemorrhages may need prophylaxis from childhood onwards. The aim of the current review is to depict an updated summary of clinical phenotype, laboratory diagnosis, and treatment of inherited Factor VII deficiency.

  13. Factor VII Deficiency: Clinical Phenotype, Genotype and Therapy

    PubMed Central

    Napolitano, Mariasanta; Siragusa, Sergio; Mariani, Guglielmo

    2017-01-01

    Factor VII deficiency is the most common among rare inherited autosomal recessive bleeding disorders, and is a chameleon disease due to the lack of a direct correlation between plasma levels of coagulation Factor VII and bleeding manifestations. Clinical phenotypes range from asymptomatic condition—even in homozygous subjects—to severe life-threatening bleedings (central nervous system, gastrointestinal bleeding). Prediction of bleeding risk is thus based on multiple parameters that challenge disease management. Spontaneous or surgical bleedings require accurate treatment schedules, and patients at high risk of severe hemorrhages may need prophylaxis from childhood onwards. The aim of the current review is to depict an updated summary of clinical phenotype, laboratory diagnosis, and treatment of inherited Factor VII deficiency. PMID:28350321

  14. Rhenium(VII) Catalysis of Prins Cyclization Reactions

    PubMed Central

    Tadpetch, Kwanruthai; Rychnovsky, Scott D.

    2009-01-01

    The rhenium(VII) complex O3ReOSiPh3 are particularly effective catalyst for Prins cyclizations using aromatic and α,β-unsaturated aldehydes. The reaction conditions are mild and the highly substituted 4-hydroxy tetrahydropyran products are formed stereoselectively. Rhenium(VII) complexes appear to spontaneously form esters with alcohols and to directly activate electron rich alcohols for solvolysis. Re2O7 and perrhenic acid were equally effective in catalyzing these cyclizations. PMID:18816133

  15. Life-threatening bleeding in a case of autoantibody-induced factor VII deficiency.

    PubMed

    Okajima, K; Ishii, M

    1999-02-01

    A male patient presented with life-threatening bleeding induced by autoantibody-induced factor VII (F.VII) deficiency. This patient had macroscopic hematuria, skin ecchymosis, gastrointestinal bleeding, and a neck hematoma that was causing disturbed respiration. He developed acute renal failure and acute hepatic failure, probably due to obstruction of the ureters and the biliary tract, respectively. Although activated partial thromboplastin time was normal, prothrombin time (PT) was remarkably prolonged at 71.8 seconds compared to 14.0 seconds in a normal control. Both the immunoreactive level of F.VII antigen and the F.VII activity of the patient's plasma samples were < 1.0% of normal. Although an equal part of normal plasma was added to the patient's plasma, PT was not corrected. The patient's plasma inhibited F.VII activity. These findings suggested the presence of a plasma inhibitor for F.VII. After administration of large doses of methylprednisolone, PT was gradually shortened and plasma levels of F.VII increased over time. Bleeding, acute renal failure, and acute hepatic failure improved markedly following the steroid treatment. These observations suggest that life-threatening bleeding can be induced by autoantibody-induced F.VII deficiency and that immunosuppressive therapy using large doses of steroid can be successful in inhibiting the production of the autoantibody.

  16. A stereoscopic system for viewing the temporal evolution of brain activity clusters in response to linguistic stimuli

    NASA Astrophysics Data System (ADS)

    Forbes, Angus; Villegas, Javier; Almryde, Kyle R.; Plante, Elena

    2014-03-01

    In this paper, we present a novel application, 3D+Time Brain View, for the stereoscopic visualization of functional Magnetic Resonance Imaging (fMRI) data gathered from participants exposed to unfamiliar spoken languages. An analysis technique based on Independent Component Analysis (ICA) is used to identify statistically significant clusters of brain activity and their changes over time during different testing sessions. That is, our system illustrates the temporal evolution of participants' brain activity as they are introduced to a foreign language through displaying these clusters as they change over time. The raw fMRI data is presented as a stereoscopic pair in an immersive environment utilizing passive stereo rendering. The clusters are presented using a ray casting technique for volume rendering. Our system incorporates the temporal information and the results of the ICA into the stereoscopic 3D rendering, making it easier for domain experts to explore and analyze the data.

  17. Towards An Understanding of Mobile Touch Navigation in a Stereoscopic Viewing Environment for 3D Data Exploration.

    PubMed

    López, David; Oehlberg, Lora; Doger, Candemir; Isenberg, Tobias

    2016-05-01

    We discuss touch-based navigation of 3D visualizations in a combined monoscopic and stereoscopic viewing environment. We identify a set of interaction modes, and a workflow that helps users transition between these modes to improve their interaction experience. In our discussion we analyze, in particular, the control-display space mapping between the different reference frames of the stereoscopic and monoscopic displays. We show how this mapping supports interactive data exploration, but may also lead to conflicts between the stereoscopic and monoscopic views due to users' movement in space; we resolve these problems through synchronization. To support our discussion, we present results from an exploratory observational evaluation with domain experts in fluid mechanics and structural biology. These experts explored domain-specific datasets using variations of a system that embodies the interaction modes and workflows; we report on their interactions and qualitative feedback on the system and its workflow.

  18. Stereoscopic Imaging in Hypersonics Boundary Layers using Planar Laser-Induced Fluorescence

    NASA Technical Reports Server (NTRS)

    Danehy, Paul M.; Bathel, Brett; Inman, Jennifer A.; Alderfer, David W.; Jones, Stephen B.

    2008-01-01

    Stereoscopic time-resolved visualization of three-dimensional structures in a hypersonic flow has been performed for the first time. Nitric Oxide (NO) was seeded into hypersonic boundary layer flows that were designed to transition from laminar to turbulent. A thick laser sheet illuminated and excited the NO, causing spatially-varying fluorescence. Two cameras in a stereoscopic configuration were used to image the fluorescence. The images were processed in a computer visualization environment to provide stereoscopic image pairs. Two methods were used to display these image pairs: a cross-eyed viewing method which can be viewed by naked eyes, and red/blue anaglyphs, which require viewing through red/blue glasses. The images visualized three-dimensional information that would be lost if conventional planar laser-induced fluorescence imaging had been used. Two model configurations were studied in NASA Langley Research Center's 31-Inch Mach 10 Air Wind tunnel. One model was a 10 degree half-angle wedge containing a small protuberance to force the flow to transition. The other model was a 1/3-scale, truncated Hyper-X forebody model with blowing through a series of holes to force the boundary layer flow to transition to turbulence. In the former case, low flowrates of pure NO seeded and marked the boundary layer fluid. In the latter, a trace concentration of NO was seeded into the injected N2 gas. The three-dimensional visualizations have an effective time resolution of about 500 ns, which is fast enough to freeze this hypersonic flow. The 512x512 resolution of the resulting images is much higher than high-speed laser-sheet scanning systems with similar time response, which typically measure 10-20 planes.

  19. Quantitative measurement of eyestrain on 3D stereoscopic display considering the eye foveation model and edge information.

    PubMed

    Heo, Hwan; Lee, Won Oh; Shin, Kwang Yong; Park, Kang Ryoung

    2014-05-15

    We propose a new method for measuring the degree of eyestrain on 3D stereoscopic displays using a glasses-type of eye tracking device. Our study is novel in the following four ways: first, the circular area where a user's gaze position exists is defined based on the calculated gaze position and gaze estimation error. Within this circular area, the position where edge strength is maximized can be detected, and we determine this position as the gaze position that has a higher probability of being the correct one. Based on this gaze point, the eye foveation model is defined. Second, we quantitatively evaluate the correlation between the degree of eyestrain and the causal factors of visual fatigue, such as the degree of change of stereoscopic disparity (CSD), stereoscopic disparity (SD), frame cancellation effect (FCE), and edge component (EC) of the 3D stereoscopic display using the eye foveation model. Third, by comparing the eyestrain in conventional 3D video and experimental 3D sample video, we analyze the characteristics of eyestrain according to various factors and types of 3D video. Fourth, by comparing the eyestrain with or without the compensation of eye saccades movement in 3D video, we analyze the characteristics of eyestrain according to the types of eye movements in 3D video. Experimental results show that the degree of CSD causes more eyestrain than other factors.

  20. Hurricane structure and wind fields from stereoscopic and infrared satellite observations and radar data

    NASA Technical Reports Server (NTRS)

    Hasler, A. F.; Morris, K. R.

    1986-01-01

    Hurricane cloud and precipitation structure have been studied by means of IR and stereoscopic visual satellite data from synchronized scanning GOES-East and -West, in combination with ground-based radar data for Hurricane Frederico and time-composited airborne radar data for Hurricane Allen. It is noted that stereoscopically measured cloudtop height in these hurricanes is not as closely correlated to radar reflectivity at lower levels as it is in intense thunderstorms over land. This and other results obtained imply that satellite precipitation estimation techniques for tropical cyclones that are based on cloudtop measurements will not be accurate with respect to time and place scales that are less than several hours and a few hundred km, respectively.

  1. 40 CFR Appendixes I-Vii to Part 85 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false [Reserved] I Appendixes I-VII to Part 85 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Appendixes I-VII to Part 85 [Reserved] ...

  2. 40 CFR Appendixes I-Vii to Part 85 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false [Reserved] I Appendixes I-VII to Part 85 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Appendixes I-VII to Part 85 [Reserved] ...

  3. 40 CFR Appendixes I-Vii to Part 85 - [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false [Reserved] I Appendixes I-VII to Part 85 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Appendixes I-VII to Part 85 [Reserved] ...

  4. 40 CFR Appendixes I-Vii to Part 85 - [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false [Reserved] I Appendixes I-VII to Part 85 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Appendixes I-VII to Part 85 [Reserved] ...

  5. 40 CFR Appendixes I-Vii to Part 85 - [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false [Reserved] I Appendixes I-VII to Part 85 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Appendixes I-VII to Part 85 [Reserved] ...

  6. Depth reversals in stereoscopic displays driven by apparent size

    NASA Astrophysics Data System (ADS)

    Sacher, Gunnar; Hayes, Amy; Thornton, Ian M.; Sereno, Margaret E.; Malony, Allen D.

    1998-04-01

    In visual scenes, depth information is derived from a variety of monocular and binocular cues. When in conflict, a monocular cue is sometimes able to override the binocular information. We examined the accuracy of relative depth judgments in orthographic, stereoscopic displays and found that perceived relative size can override binocular disparity as a depth cue in a situation where the relative size information is itself generated from disparity information, not from retinal size difference. A size discrimination task confirmed the assumption that disparity information was perceived and used to generate apparent size differences. The tendency for the apparent size cue to override disparity information can be modulated by varying the strength of the apparent size cue. In addition, an analysis of reaction times provides supporting evidence for this novel depth reversal effect. We believe that human perception must be regarded as an important component of stereoscopic applications. Hence, if applications are to be effective and accurate, it is necessary to take into account the richness and complexity of the human visual perceptual system that interacts with them. We discuss implications of this and similar research for human performance in virtual environments, the design of visual presentations for virtual worlds, and the design of visualization tools.

  7. SUPPORT FOR BEIR VII

    EPA Science Inventory

    The office is supporting the continued funding of National Academy of Sciences Study to update our understanding of the effects of low-level radiation. In particular, this study, entitled the Biological Effects of Ionizing Radiation VII, will draw upon the most recent data avail...

  8. Recombinant factor VIIa treatment for asymptomatic factor VII deficient patients going through major surgery.

    PubMed

    Livnat, Tami; Shenkman, Boris; Spectre, Galia; Tamarin, Ilia; Dardik, Rima; Israeli, Amnon; Rivkind, Avraham; Shabtai, Moshe; Marinowitz, Uri; Salomon, Ophira

    2012-07-01

    Factor VII deficiency is the most common among the rare autosomal recessive coagulation disorders worldwide. In factor VII deficient patients, the severity and clinical manifestations cannot be reliably determined by factor VII levels. Severe bleeding tends to occur in individuals with factor VII activity levels of 2% or less of normal. Patients with 2-10% factor VII vary between asymptomatic to severe life threatening haemorrhages behaviour. Recombinant factor VIIa (rFVIIa) is the most common replacement therapy for congenital factor VII deficiency. However, unlike haemophilia patients for whom treatment protocols are straight forward, in asymptomatic factor VII deficiency patients it is still debatable. In this study, we demonstrate that a single and very low dose of recombinant factor VIIa enabled asymptomatic patients with factor VII deficiency to go through major surgery safely. This suggestion was also supported by thrombin generation, as well as by thromboelastometry.

  9. 40 CFR Appendixes Vi-Vii to Part 600 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false [Reserved] VI Appendixes VI-VII to Part 600 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Appendixes VI-VII to Part 600 [Reserved] ...

  10. 40 CFR Appendixes Vi-Vii to Part 600 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false [Reserved] VI Appendixes VI-VII to Part 600 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Appendixes VI-VII to Part 600 [Reserved] ...

  11. Tissue Factor-Factor VII Complex As a Key Regulator of Ovarian Cancer Phenotypes.

    PubMed

    Koizume, Shiro; Miyagi, Yohei

    2015-01-01

    Tissue factor (TF) is an integral membrane protein widely expressed in normal human cells. Blood coagulation factor VII (fVII) is a key enzyme in the extrinsic coagulation cascade that is predominantly secreted by hepatocytes and released into the bloodstream. The TF-fVII complex is aberrantly expressed on the surface of cancer cells, including ovarian cancer cells. This procoagulant complex can initiate intracellular signaling mechanisms, resulting in malignant phenotypes. Cancer tissues are chronically exposed to hypoxia. TF and fVII can be induced in response to hypoxia in ovarian cancer cells at the gene expression level, leading to the autonomous production of the TF-fVII complex. Here, we discuss the roles of the TF-fVII complex in the induction of malignant phenotypes in ovarian cancer cells. The hypoxic nature of ovarian cancer tissues and the roles of TF expression in endometriosis are discussed. Arguments will be extended to potential strategies to treat ovarian cancers based on our current knowledge of TF-fVII function.

  12. Self-calibration performance in stereoscopic PIV acquired in a transonic wind tunnel

    DOE PAGES

    Beresh, Steven J.; Wagner, Justin L.; Smith, Barton L.

    2016-03-16

    Three stereoscopic PIV experiments have been examined to test the effectiveness of self-calibration under varied circumstances. Furthermore, we our measurements taken in a streamwise plane yielded a robust self-calibration that returned common results regardless of the specific calibration procedure, but measurements in the crossplane exhibited substantial velocity bias errors whose nature was sensitive to the particulars of the self-calibration approach. Self-calibration is complicated by thick laser sheets and large stereoscopic camera angles and further exacerbated by small particle image diameters and high particle seeding density. In spite of the different answers obtained by varied self-calibrations, each implementation locked onto anmore » apparently valid solution with small residual disparity and converged adjustment of the calibration plane. Thus, the convergence of self-calibration on a solution with small disparity is not sufficient to indicate negligible velocity error due to the stereo calibration.« less

  13. Anatomic Variability of the Upper Mediastinal Lymph Node Level VII.

    PubMed

    Hartl, Dana M; Breuskin, Ingrid; Mirghani, Haïtham; Berdelou, Amandine; Déandréis, Désirée; Pottier, Edwige; Borget, Isabelle; Schlumberger, Martin; Leboulleux, Sophie

    2016-08-01

    Lymph node level VII, between the sternal notch and the innominate artery, is a frequent site of lymph node metastases in thyroid cancer. The objective of this study was to determine the cranial-caudal dimensions of level VII in patients undergoing central neck dissection for thyroid cancer and its accessibility through a neck incision only. Consecutive patients undergoing central neck dissection for thyroid cancer, with no previous neck dissection, mediastinal or thoracic surgery. The innominate artery was identified and the distance between the sternal notch and the upper border of the artery was measured to the nearest .5 mm. The sizes of level VII were compared with respect to age, sex, height, body mass index, type of neck dissection (therapeutic or prophylactic), and the incidence of previous thyroidectomy. One-hundred-one consecutive patients (65 women, 36 men, mean age 44 years (range 15-87) underwent prophylactic (n = 55) or therapeutic (n = 46) bilateral central compartment neck dissection. Level VII was accessible via the horizontal neck incision in all cases. Sizes of level VII ranged from 6 cm above the sternal notch to 35 mm below the sternal notch, with a mean distance of 3.5 mm below the sternal notch. The innominate artery was at the level of the sternal notch in 29 patients, and cranial to the sternal notch in 20 cases. No statistical relationship with age, sex, therapeutic/prophylactic neck dissection, previous surgery, body mass index or height was found. The maximal distance below the sternal notch was 35 mm. Level VII did not exist in 49 % of patients, and was less than 25 mm caudal to the sternal notch in 95 % of cases. Distinguishing level VII from level VI in thyroid cancer surgery may not be pertinent, due to the ease of access via a classic horizontal neck incision and the small sizes of level VII in the majority of patients.

  14. Interrelation between factor VII, prekallikrein, and hyperfibrinolysis in advanced cirrhosis.

    PubMed Central

    Violi, F; Alessandri, C; Ferro, D; Saliola, M; Cordova, C; Musca, A; Balsano, F

    1989-01-01

    Factor VII and prekallikrein activities were studied in 37 patients with liver cirrhosis who were in a decompensated state. Sixteen of them died 30-70 days after admission; 21 survived and were discharged after 30-80 days. Seven who died and six survivors had signs of hyperfibrinolysis: factor VII activity differentiated the two groups independently of the presence of hyperfibrinolysis. The presence of hyperfibrinolysis significantly reduced prekallikrein activity, which did not differentiate clearly survivors from non-survivors. Long term follow up of survivors showed a good correlation between factor VII and prekallikrein activities with long term survival. Hyperfibrinolysis seemed to influence the clinical course of patients: 87% of patients with hyperfibrinolysis who died had fatal haemorrhagic episodes. Low factor VII activity may be a precursor of terminal liver insufficiency. PMID:2613916

  15. Implementation Practices of Bilingual Education Programs.

    ERIC Educational Resources Information Center

    Ortiz, Flora Ida

    The ethnographic study investigated the implementation practices of a bilingual education program. A school site containing factors which were determined to be prevalent across Title VII programs was selected from over 300 Title VII sites. In addition, the school also contained a local student population, i.e., no one was bused from elsewhere; two…

  16. Learning from history: the legacy of Title VII in academic family medicine.

    PubMed

    Newton, Warren; Arndt, Jane E

    2008-11-01

    The current renaissance of interest in primary care could benefit from reviewing the history of federal investment in academic family medicine. The authors review 30 years of experience with the Title VII, Section 747 Training in Primary Care Medicine and Dentistry (Title VII) grant program, addressing three questions: (1) What Title VII grant programs were available to family medicine, and what were their goals? (2) How did Title VII change the discipline? and (3) What impact did Title VII family medicine programs have outside the discipline?Title VII grant programs evolved from broad support for the new discipline of family medicine to a sharper focus on specific national workforce objectives such as improving care for underserved and vulnerable populations and increasing diversity in the health professions. Grant programs were instrumental in establishing family medicine in nearly all medical schools and in supporting the educational underpinnings of the field. Title VII grants helped enhance the social capital of the discipline. Outside family medicine, Title VII fostered the development of innovative ambulatory education, institutional initiatives focusing on underserved and vulnerable populations, and primary care research capacity. Adverse effects include relative inattention to clinical and research missions in family medicine academic units and, institutionally, the development of medical education initiatives without core institutional support, which has put innovation and extension of education to communities at risk as grant funding has decreased. Reinvestment in academic family medicine can yield substantial benefits for family medicine and help reorient academic health centers. This article is part of a theme issue of Academic Medicine on the Title VII health professions training programs.

  17. Factor VII deficiency: a single-center experience.

    PubMed

    Salcioglu, Zafer; Akcay, Arzu; Sen, Hulya Sayilan; Aydogan, Gonul; Akici, Ferhan; Tugcu, Deniz; Ayaz, Nuray Aktay; Baslar, Zafer

    2012-11-01

    Congenital factor VII deficiency is the most common form of rare coagulation factor deficiencies. This article presents a retrospective evaluation of 73 factor VII deficiency cases that had been followed at our center. The study consisted of 48 males and 25 females (2 months-19 years). Thirty-one (42.5%) of them were asymptomatic. Out of symptomatic patients, 17 had severe clinical symptoms, whereas 8 presented with moderate and 17 with mild symptoms. The symptoms listed in order of frequency were as follows: epistaxis, petechia or ecchymose, easy bruising, and oral cavity bleeding. The genotype was determined in 8 patients. Recombinant activated factor VII (rFVIIa) was used to treat 49 bleeding episodes in 8 patients after 2002. In 2 patients with repeated central nervous system bleeding prophylaxis with rFVIIa was administered. No allergic and thrombotic events were observed during both treatment and prophylaxis courses. Antibody occurrence was not detected in the patients during treatment.

  18. What is 3D good for? A review of human performance on stereoscopic 3D displays

    NASA Astrophysics Data System (ADS)

    McIntire, John P.; Havig, Paul R.; Geiselman, Eric E.

    2012-06-01

    This work reviews the human factors-related literature on the task performance implications of stereoscopic 3D displays, in order to point out the specific performance benefits (or lack thereof) one might reasonably expect to observe when utilizing these displays. What exactly is 3D good for? Relative to traditional 2D displays, stereoscopic displays have been shown to enhance performance on a variety of depth-related tasks. These tasks include judging absolute and relative distances, finding and identifying objects (by breaking camouflage and eliciting perceptual "pop-out"), performing spatial manipulations of objects (object positioning, orienting, and tracking), and navigating. More cognitively, stereoscopic displays can improve the spatial understanding of 3D scenes or objects, improve memory/recall of scenes or objects, and improve learning of spatial relationships and environments. However, for tasks that are relatively simple, that do not strictly require depth information for good performance, where other strong cues to depth can be utilized, or for depth tasks that lie outside the effective viewing volume of the display, the purported performance benefits of 3D may be small or altogether absent. Stereoscopic 3D displays come with a host of unique human factors problems including the simulator-sickness-type symptoms of eyestrain, headache, fatigue, disorientation, nausea, and malaise, which appear to effect large numbers of viewers (perhaps as many as 25% to 50% of the general population). Thus, 3D technology should be wielded delicately and applied carefully; and perhaps used only as is necessary to ensure good performance.

  19. Deep-level stereoscopic multiple traps of acoustic vortices

    NASA Astrophysics Data System (ADS)

    Li, Yuzhi; Guo, Gepu; Ma, Qingyu; Tu, Juan; Zhang, Dong

    2017-04-01

    Based on the radiation pattern of a planar piston transducer, the mechanisms underlying the generation of axially controllable deep-level stereoscopic multiple traps of acoustic vortices (AV) using sparse directional sources were proposed with explicit formulae. Numerical simulations for the axial and cross-sectional distributions of acoustic pressure and phase were conducted for various ka (product of the wave number and the radius of transducer) values at the frequency of 1 MHz. It was demonstrated that, for bigger ka, besides the main-AV (M-AV) generated by the main lobes of the sources, cone-shaped side-AV (S-AV) produced by the side lobes were closer to the source plane at a relatively lower pressure. Corresponding to the radiation angles of pressure nulls between the main lobe and the side lobes of the sources, vortex valleys with nearly pressure zero could be generated on the central axis to form multiple traps, based on Gor'kov potential theory. The number and locations of vortex valleys could be controlled accurately by the adjustment of ka. With the established eight-source AV generation system, the existence of the axially controllable multiple traps was verified by the measured M-AV and S-AVs as well as the corresponding vortex valleys. The favorable results provided the feasibility of deep-level stereoscopic control of AV and suggested potential application of multiple traps for particle manipulation in the area of biomedical engineering.

  20. Quantitative Measurement of Eyestrain on 3D Stereoscopic Display Considering the Eye Foveation Model and Edge Information

    PubMed Central

    Heo, Hwan; Lee, Won Oh; Shin, Kwang Yong; Park, Kang Ryoung

    2014-01-01

    We propose a new method for measuring the degree of eyestrain on 3D stereoscopic displays using a glasses-type of eye tracking device. Our study is novel in the following four ways: first, the circular area where a user's gaze position exists is defined based on the calculated gaze position and gaze estimation error. Within this circular area, the position where edge strength is maximized can be detected, and we determine this position as the gaze position that has a higher probability of being the correct one. Based on this gaze point, the eye foveation model is defined. Second, we quantitatively evaluate the correlation between the degree of eyestrain and the causal factors of visual fatigue, such as the degree of change of stereoscopic disparity (CSD), stereoscopic disparity (SD), frame cancellation effect (FCE), and edge component (EC) of the 3D stereoscopic display using the eye foveation model. Third, by comparing the eyestrain in conventional 3D video and experimental 3D sample video, we analyze the characteristics of eyestrain according to various factors and types of 3D video. Fourth, by comparing the eyestrain with or without the compensation of eye saccades movement in 3D video, we analyze the characteristics of eyestrain according to the types of eye movements in 3D video. Experimental results show that the degree of CSD causes more eyestrain than other factors. PMID:24834910

  1. Evaluation of a stereoscopic camera-based three-dimensional viewing workstation for ophthalmic surgery.

    PubMed

    Bhadri, Prashant R; Rowley, Adrian P; Khurana, Rahul N; Deboer, Charles M; Kerns, Ralph M; Chong, Lawrence P; Humayun, Mark S

    2007-05-01

    To evaluate the effectiveness of a prototype stereoscopic camera-based viewing system (Digital Microsurgical Workstation, three-dimensional (3D) Vision Systems, Irvine, California, USA) for anterior and posterior segment ophthalmic surgery. Institutional-based prospective study. Anterior and posterior segment surgeons performed designated standardized tasks on porcine eyes after training on prosthetic plastic eyes. Both anterior and posterior segment surgeons were able to complete tasks requiring minimal or moderate stereoscopic viewing. The results indicate that the system provides improved ergonomics. Improvements in key viewing performance areas would further enhance the value over a conventional operating microscope. The performance of the prototype system is not at par with the planned commercial system. With continued development of this technology, the three- dimensional system may be a novel viewing system in ophthalmic surgery with improved ergonomics with respect to traditional microscopic viewing.

  2. Interactive and Stereoscopic Hybrid 3D Viewer of Radar Data with Gesture Recognition

    NASA Astrophysics Data System (ADS)

    Goenetxea, Jon; Moreno, Aitor; Unzueta, Luis; Galdós, Andoni; Segura, Álvaro

    This work presents an interactive and stereoscopic 3D viewer of weather information coming from a Doppler radar. The hybrid system shows a GIS model of the regional zone where the radar is located and the corresponding reconstructed 3D volume weather data. To enhance the immersiveness of the navigation, stereoscopic visualization has been added to the viewer, using a polarized glasses based system. The user can interact with the 3D virtual world using a Nintendo Wiimote for navigating through it and a Nintendo Wii Nunchuk for giving commands by means of hand gestures. We also present a dynamic gesture recognition procedure that measures the temporal advance of the performed gesture postures. Experimental results show how dynamic gestures are effectively recognized so that a more natural interaction and immersive navigation in the virtual world is achieved.

  3. Gentamicin induces functional type VII collagen in recessive dystrophic epidermolysis bullosa patients

    PubMed Central

    Woodley, David T.; Cogan, Jon; Hou, Yingping; Lyu, Chao; Marinkovich, M. Peter; Keene, Douglas

    2017-01-01

    BACKGROUND. Recessive dystrophic epidermolysis bullosa (RDEB) is an incurable disease caused by mutations in the gene encoding type VII collagen, the major component of anchoring fibrils (AF). We previously demonstrated that gentamicin produced functional type VII collagen in RDEB cells harboring nonsense mutations. Herein, we determined whether topical or intradermal gentamicin administration induces type VII collagen and AFs in RDEB patients. METHODS. A double-blind, placebo-controlled pilot trial assessed safety and efficacy of topical and intradermal gentamicin in 5 RDEB patients with nonsense mutations. The topical arm tested 0.1% gentamicin ointment or placebo application 3 times daily at 2 open erosion sites for 2 weeks. The intradermal arm tested daily intradermal injection of gentamicin solution (8 mg) or placebo into 2 intact skin sites for 2 days in 4 of 5 patients. Primary outcomes were induction of type VII collagen and AFs at the test sites and safety assessment. A secondary outcome assessed wound closure of topically treated erosions. RESULTS. Both topical and intradermal gentamicin administration induced type VII collagen and AFs at the dermal-epidermal junction of treatment sites. Newly created type VII collagen varied from 20% to 165% of that expressed in normal human skin and persisted for 3 months. Topical gentamicin corrected dermal-epidermal separation, improved wound closure, and reduced blister formation. There were no untoward side effects from gentamicin treatments. Type VII collagen induction did not generate anti–type VII collagen autoantibodies in patients’ blood or skin. CONCLUSION. Topical and intradermal gentamicin suppresses nonsense mutations and induces type VII collagen and AFs in RDEB patients. Gentamicin therapy may provide a readily available treatment for RDEB patients with nonsense mutations. TRIAL REGISTRATION. ClinicalTrials.gov NCT02698735. FUNDING. Epidermolysis Bullosa Research Partnership, Epidermolysis Bullosa

  4. Structural incorporation of MgCl2 into ice VII at room temperature

    NASA Astrophysics Data System (ADS)

    Watanabe, Mao; Komatsu, Kazuki; Noritake, Fumiya; Kagi, Hiroyuki

    2017-05-01

    Raman spectra and X-ray diffraction patterns were obtained from 1:100 and 1:200 \\text{MgCl}2:\\text{H}2\\text{O} solutions (in molar ratio) at pressures up to 6 GPa using diamond anvil cells (DACs) and compared with those of pure water. The O-H stretching band from ice VII crystallized from the 1:200 solution was approximately 10 cm-1 higher than that of pure ice VII. The phase boundaries between ice VII and VIII crystallized from the MgCl2 solutions at 4 GPa were 2 K lower than those of pure ice VII and VIII. These observations indicate that ice VII incorporates MgCl2 into its structure. The unit cell volumes of ice VII crystallized from pure water and the two solutions coincided with each other within the experimental error, and salt incorporation was not detectable from the cell volume. Possible configurations of ion substitution and excess volume of ice VIII were simulated on the basis of density functional theory (DFT) calculations.

  5. Evaluation of stereoscopic video cameras synchronized with the movement of an operator's head on the teleoperation of the actual backhoe shovel

    NASA Astrophysics Data System (ADS)

    Minamoto, Masahiko; Matsunaga, Katsuya

    1999-05-01

    Operator performance while using a remote controlled backhoe shovel is described for three different stereoscopic viewing conditions: direct view, fixed stereoscopic cameras connected to a helmet mounted display (HMD), and rotating stereo camera connected and slaved to the head orientation of a free moving stereo HMD. Results showed that the head- slaved system provided the best performance.

  6. Distortion of depth perception in virtual environments using stereoscopic displays: quantitative assessment and corrective measures

    NASA Astrophysics Data System (ADS)

    Kleiber, Michael; Winkelholz, Carsten

    2008-02-01

    The aim of the presented research was to quantify the distortion of depth perception when using stereoscopic displays. The visualization parameters of the used virtual reality system such as perspective, haploscopic separation and width of stereoscopic separation were varied. The experiment was designed to measure distortion in depth perception according to allocentric frames of reference. The results of the experiments indicate that some of the parameters have an antithetic effect which allows to compensate the distortion of depth perception for a range of depths. In contrast to earlier research which reported underestimation of depth perception we found that depth was overestimated when using true projection parameters according to the position of the eyes of the user and display geometry.

  7. LAWS ON SEX DISCRIMINATION IN EMPLOYMENT--FEDERAL CIVIL RIGHTS ACT, TITLE VII. STATE FAIR EMPLOYMENT PRACTICES LAWS.

    ERIC Educational Resources Information Center

    Women's Bureau (DOL), Washington, DC.

    TITLE VII OF THE FEDERAL CIVIL RIGHTS ACT (1964) PROHIBITS DISCRIMINATION ON THE BASIS OF SEX IN ADDITION TO THE USUAL GROUNDS OF RACE, COLOR, RELIGION, AND NATIONAL ORIGIN. IT COVERS PRIVATE EMPLOYMENT AND LABOR ORGANIZATIONS ENGAGED IN INDUSTRIES AFFECTING COMMERCE, AS WELL AS EMPLOYMENT AGENCIES. IT IS UNLAWFUL FOR EMPLOYERS TO REFUSE TO HIRE,…

  8. The right view from the wrong location: depth perception in stereoscopic multi-user virtual environments.

    PubMed

    Pollock, Brice; Burton, Melissa; Kelly, Jonathan W; Gilbert, Stephen; Winer, Eliot

    2012-04-01

    Stereoscopic depth cues improve depth perception and increase immersion within virtual environments (VEs). However, improper display of these cues can distort perceived distances and directions. Consider a multi-user VE, where all users view identical stereoscopic images regardless of physical location. In this scenario, cues are typically customized for one "leader" equipped with a head-tracking device. This user stands at the center of projection (CoP) and all other users ("followers") view the scene from other locations and receive improper depth cues. This paper examines perceived depth distortion when viewing stereoscopic VEs from follower perspectives and the impact of these distortions on collaborative spatial judgments. Pairs of participants made collaborative depth judgments of virtual shapes viewed from the CoP or after displacement forward or backward. Forward and backward displacement caused perceived depth compression and expansion, respectively, with greater compression than expansion. Furthermore, distortion was less than predicted by a ray-intersection model of stereo geometry. Collaboration times were significantly longer when participants stood at different locations compared to the same location, and increased with greater perceived depth discrepancy between the two viewing locations. These findings advance our understanding of spatial distortions in multi-user VEs, and suggest a strategy for reducing distortion.

  9. Age-dependent regulation of ERF-VII transcription factor activity in Arabidopsis thaliana.

    PubMed

    Giuntoli, Beatrice; Shukla, Vinay; Maggiorelli, Federica; Giorgi, Federico M; Lombardi, Lara; Perata, Pierdomenico; Licausi, Francesco

    2017-10-01

    The Group VII Ethylene Responsive Factors (ERFs-VII) RAP2.2 and RAP2.12 have been mainly characterized with regard to their contribution as activators of fermentation in plants. However, transcriptional changes measured in conditions that stabilize these transcription factors exceed the mere activation of this biochemical pathway, implying additional roles performed by the ERF-VIIs in other processes. We evaluated gene expression in transgenic Arabidopsis lines expressing a stabilized form of RAP2.12, or hampered in ERF-VII activity, and identified genes affected by this transcriptional regulator and its homologs, including some involved in oxidative stress response, which are not universally induced under anaerobic conditions. The contribution of the ERF-VIIs in regulating this set of genes in response to chemically induced or submergence-stimulated mitochondria malfunctioning was found to depend on the plant developmental stage. A similar age-dependent mechanism also restrained ERF-VII activity upon the core-hypoxic genes, independently of the N-end rule pathway, which is accounted for the control of the anaerobic response. To conclude, this study shed new light on a dual role of ERF-VII proteins under submergence: as positive regulators of the hypoxic response and as repressors of oxidative-stress related genes, depending on the developmental stage at which plants are challenged by stress conditions. © 2017 John Wiley & Sons Ltd.

  10. Blister-inducing antibodies target multiple epitopes on collagen VII in mice

    PubMed Central

    Csorba, Kinga; Chiriac, Mircea Teodor; Florea, Florina; Ghinia, Miruna Georgiana; Licarete, Emilia; Rados, Andreea; Sas, Alexandra; Vuta, Vlad; Sitaru, Cassian

    2014-01-01

    Epidermolysis bullosa acquisita (EBA) is an autoimmune subepidermal blistering disease of mucous membranes and the skin caused by autoantibodies against collagen VII. In silico and wet laboratory epitope mapping studies revealed numerous distinct epitopes recognized by EBA patients' autoantibodies within the non-collagenous (NC)1 and NC2 domains of collagen VII. However, the distribution of pathogenic epitopes on collagen VII has not yet been described. In this study, we therefore performed an in vivo functional epitope mapping of pathogenic autoantibodies in experimental EBA. Animals (n = 10/group) immunized against fragments of the NC1 and NC2 domains of collagen VII or injected with antibodies generated against the same fragments developed to different extent experimental EBA. Our results demonstrate that antibodies targeting multiple, distinct epitopes distributed over the entire NC1, but not NC2 domain of collagen VII induce blistering skin disease in vivo. Our present findings have crucial implications for the development of antigen-specific B- and T cell-targeted therapies in EBA. PMID:25091020

  11. The Real Time Correction of Stereoscopic Images: From the Serial to a Parallel Treatment

    NASA Astrophysics Data System (ADS)

    Irki, Zohir; Devy, Michel; Achour, Karim; Azzaz, Mohamed Salah

    2008-06-01

    The correction of the stereoscopic images is a task which consists in replacing acquired images by other images having the same properties but which are simpler to use in the other stages of stereovision. The use of the pre-calculated tables, built during an off line calibration step, made it possible to carry out the off line stereoscopic images rectification. An improvement of the built tables made it possible to carry out the real time rectification. In this paper, we describe an improvement of the real time correction approach so it can be exploited for a possible implementation on an FPGA component. This improvement holds in account the real time aspect of the correction and the available resources that can offer the FPGA Type Stratix 1S40F780C5.

  12. Stereoscopic video analysis of Anopheles gambiae behavior in the field: challenges and opportunities

    USDA-ARS?s Scientific Manuscript database

    Advances in our ability to localize and track individual swarming mosquitoes in the field via stereoscopic image analysis have enabled us to test long standing ideas about individual male behavior and directly observe coupling. These studies further our fundamental understanding of the reproductive ...

  13. Pathogenesis of aortic dilatation in mucopolysaccharidosis VII mice may involve complement activation

    PubMed Central

    Baldo, Guilherme; Wu, Susan; Howe, Ruth A.; Ramamoothy, Meera; Knutsen, Russell H.; Fang, Jiali; Mecham, Robert P.; Liu, Yuli; Wu, Xiaobo; Atkinson, John P.; Ponder, Katherine P.

    2012-01-01

    Mucopolysaccharidosis VII (MPS VII) is due to mutations within the gene encoding the lysosomal enzyme β-glucuronidase, and results in the accumulation of glycosaminoglycans. MPS VII causes aortic dilatation and elastin fragmentation, which is associated with upregulation of the elastases cathepsin S (CtsS) and matrix metalloproteinase 12 (MMP12). To test the role of these enzymes, MPS VII mice were crossed with mice deficient in CtsS or MMP12, and the effect upon aortic dilatation was determined. CtsS deficiency did not protect against aortic dilatation in MPS VII mice, but also failed to prevent an upregulation of cathepsin enzyme activity. Further analysis with substrates and inhibitors specific for particular cathepsins suggests that this enzyme activity was due to CtsB, which could contribute to elastin fragmentation. Similarly, MMP12 deficiency and deficiency of both MMP12 and CtsS could not prevent aortic dilatation in MPS VII mice. Microarray and reverse-transcriptase real-time PCR were performed to look for upregulation of other elastases. This demonstrated that mRNA for complement component D was elevated in MPS VII mice, while immunostaining demonstrated high levels of complement component C3 on surfaces within the aortic media. Finally, we demonstrate that neonatal intravenous injection of a retroviral vector encoding β-glucuronidase reduced aortic dilatation. We conclude that neither CtsS nor MMP12 are necessary for elastin fragmentation in MPS VII mouse aorta, and propose that CtsB and/or complement component D may be involved. Complement may be activated by the GAGs that accumulate, and may play a role in signal transduction pathways that upregulate elastases. PMID:21944884

  14. Evaluating a Novel 3D Stereoscopic Visual Display for Transanal Endoscopic Surgery: A Randomized Controlled Crossover Study.

    PubMed

    Di Marco, Aimee N; Jeyakumar, Jenifa; Pratt, Philip J; Yang, Guang-Zhong; Darzi, Ara W

    2016-01-01

    To compare surgical performance with transanal endoscopic surgery (TES) using a novel 3-dimensional (3D) stereoscopic viewer against the current modalities of a 3D stereoendoscope, 3D, and 2-dimensional (2D) high-definition monitors. TES is accepted as the primary treatment for selected rectal tumors. Current TES systems offer a 2D monitor, or 3D image, viewed directly via a stereoendoscope, necessitating an uncomfortable operating position. To address this and provide a platform for future image augmentation, a 3D stereoscopic display was created. Forty participants, of mixed experience level, completed a simulated TES task using 4 visual displays (novel stereoscopic viewer and currently utilized stereoendoscope, 3D, and 2D high-definition monitors) in a randomly allocated order. Primary outcome measures were: time taken, path length, and accuracy. Secondary outcomes were: task workload and participant questionnaire results. Median time taken and path length were significantly shorter for the novel viewer versus 2D and 3D, and not significantly different to the traditional stereoendoscope. Significant differences were found in accuracy, task workload, and questionnaire assessment in favor of the novel viewer, as compared to all 3 modalities. This novel 3D stereoscopic viewer allows surgical performance in TES equivalent to that achieved using the current stereoendoscope and superior to standard 2D and 3D displays, but with lower physical and mental demands for the surgeon. Participants expressed a preference for this system, ranking it more highly on a questionnaire. Clinical translation of this work has begun with the novel viewer being used in 5 TES patients.

  15. Neuronal carbonic anhydrase VII provides GABAergic excitatory drive to exacerbate febrile seizures

    PubMed Central

    Ruusuvuori, Eva; Huebner, Antje K; Kirilkin, Ilya; Yukin, Alexey Y; Blaesse, Peter; Helmy, Mohamed; Jung Kang, Hyo; El Muayed, Malek; Christopher Hennings, J; Voipio, Juha; Šestan, Nenad; Hübner, Christian A; Kaila, Kai

    2013-01-01

    Brain carbonic anhydrases (CAs) are known to modulate neuronal signalling. Using a novel CA VII (Car7) knockout (KO) mouse as well as a CA II (Car2) KO and a CA II/VII double KO, we show that mature hippocampal pyramidal neurons are endowed with two cytosolic isoforms. CA VII is predominantly expressed by neurons starting around postnatal day 10 (P10). The ubiquitous isoform II is expressed in neurons at P20. Both isoforms enhance bicarbonate-driven GABAergic excitation during intense GABAA-receptor activation. P13–14 CA VII KO mice show behavioural manifestations atypical of experimental febrile seizures (eFS) and a complete absence of electrographic seizures. A low dose of diazepam promotes eFS in P13–P14 rat pups, whereas seizures are blocked at higher concentrations that suppress breathing. Thus, the respiratory alkalosis-dependent eFS are exacerbated by GABAergic excitation. We found that CA VII mRNA is expressed in the human cerebral cortex before the age when febrile seizures (FS) occur in children. Our data indicate that CA VII is a key molecule in age-dependent neuronal pH regulation with consequent effects on generation of FS. PMID:23881097

  16. Wide-Field-of-View, High-Resolution, Stereoscopic Imager

    NASA Technical Reports Server (NTRS)

    Prechtl, Eric F.; Sedwick, Raymond J.

    2010-01-01

    A device combines video feeds from multiple cameras to provide wide-field-of-view, high-resolution, stereoscopic video to the user. The prototype under development consists of two camera assemblies, one for each eye. One of these assemblies incorporates a mounting structure with multiple cameras attached at offset angles. The video signals from the cameras are fed to a central processing platform where each frame is color processed and mapped into a single contiguous wide-field-of-view image. Because the resolution of most display devices is typically smaller than the processed map, a cropped portion of the video feed is output to the display device. The positioning of the cropped window will likely be controlled through the use of a head tracking device, allowing the user to turn his or her head side-to-side or up and down to view different portions of the captured image. There are multiple options for the display of the stereoscopic image. The use of head mounted displays is one likely implementation. However, the use of 3D projection technologies is another potential technology under consideration, The technology can be adapted in a multitude of ways. The computing platform is scalable, such that the number, resolution, and sensitivity of the cameras can be leveraged to improve image resolution and field of view. Miniaturization efforts can be pursued to shrink the package down for better mobility. Power savings studies can be performed to enable unattended, remote sensing packages. Image compression and transmission technologies can be incorporated to enable an improved telepresence experience.

  17. Many-core computing for space-based stereoscopic imaging

    NASA Astrophysics Data System (ADS)

    McCall, Paul; Torres, Gildo; LeGrand, Keith; Adjouadi, Malek; Liu, Chen; Darling, Jacob; Pernicka, Henry

    The potential benefits of using parallel computing in real-time visual-based satellite proximity operations missions are investigated. Improvements in performance and relative navigation solutions over single thread systems can be achieved through multi- and many-core computing. Stochastic relative orbit determination methods benefit from the higher measurement frequencies, allowing them to more accurately determine the associated statistical properties of the relative orbital elements. More accurate orbit determination can lead to reduced fuel consumption and extended mission capabilities and duration. Inherent to the process of stereoscopic image processing is the difficulty of loading, managing, parsing, and evaluating large amounts of data efficiently, which may result in delays or highly time consuming processes for single (or few) processor systems or platforms. In this research we utilize the Single-Chip Cloud Computer (SCC), a fully programmable 48-core experimental processor, created by Intel Labs as a platform for many-core software research, provided with a high-speed on-chip network for sharing information along with advanced power management technologies and support for message-passing. The results from utilizing the SCC platform for the stereoscopic image processing application are presented in the form of Performance, Power, Energy, and Energy-Delay-Product (EDP) metrics. Also, a comparison between the SCC results and those obtained from executing the same application on a commercial PC are presented, showing the potential benefits of utilizing the SCC in particular, and any many-core platforms in general for real-time processing of visual-based satellite proximity operations missions.

  18. Compression Freezing Kinetics of Water to Ice VII

    DOE PAGES

    Gleason, A. E.; Bolme, C. A.; Galtier, E.; ...

    2017-07-11

    Time-resolved x-ray diffraction (XRD) of compressed liquid water shows transformation to ice VII in 6 nsec, revealing crystallization rather than amorphous solidification during compression freezing. Application of classical nucleation theory indicates heterogeneous nucleation and one-dimensional (e.g., needlelike) growth. In conclusion, these first XRD data demonstrate rapid growth kinetics of ice VII with implications for fundamental physics of diffusion-mediated crystallization and thermodynamic modeling of collision or impact events on ice-rich planetary bodies.

  19. Compression Freezing Kinetics of Water to Ice VII

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gleason, A. E.; Bolme, C. A.; Galtier, E.

    Time-resolved x-ray diffraction (XRD) of compressed liquid water shows transformation to ice VII in 6 nsec, revealing crystallization rather than amorphous solidification during compression freezing. Application of classical nucleation theory indicates heterogeneous nucleation and one-dimensional (e.g., needlelike) growth. In conclusion, these first XRD data demonstrate rapid growth kinetics of ice VII with implications for fundamental physics of diffusion-mediated crystallization and thermodynamic modeling of collision or impact events on ice-rich planetary bodies.

  20. Disparity modification in stereoscopic images for emotional enhancement

    NASA Astrophysics Data System (ADS)

    Kawai, Takashi; Atsuta, Daiki; Kim, Sanghyun; Häkkinen, Jukka

    2015-03-01

    This paper describes an experiment that focuses on disparity changes in emotional scenes of stereoscopic (3D) images, in which an examination of the effects on pleasant and arousal was carried out by adding binocular disparity to 2D images that evoke specific emotions, and applying disparity modification based on the disparity analysis of prominent 3D movies. From the results of the experiment, it was found that pleasant and arousal was increased by expanding 3D space to a certain level. In addition, pleasant gradually decreased and arousal gradually increased by expansion of 3D space above a certain level.

  1. Stereoscopic, Force-Feedback Trainer For Telerobot Operators

    NASA Technical Reports Server (NTRS)

    Kim, Won S.; Schenker, Paul S.; Bejczy, Antal K.

    1994-01-01

    Computer-controlled simulator for training technicians to operate remote robots provides both visual and kinesthetic virtual reality. Used during initial stage of training; saves time and expense, increases operational safety, and prevents damage to robots by inexperienced operators. Computes virtual contact forces and torques of compliant robot in real time, providing operator with feel of forces experienced by manipulator as well as view in any of three modes: single view, two split views, or stereoscopic view. From keyboard, user specifies force-reflection gain and stiffness of manipulator hand for three translational and three rotational axes. System offers two simulated telerobotic tasks: insertion of peg in hole in three dimensions, and removal and insertion of drawer.

  2. Plasmodium falciparum ookinete expression of plasmepsin VII and plasmepsin X.

    PubMed

    Li, Fengwu; Bounkeua, Viengngeun; Pettersen, Kenneth; Vinetz, Joseph M

    2016-02-24

    Plasmodium invasion of the mosquito midgut is a population bottleneck in the parasite lifecycle. Interference with molecular mechanisms by which the ookinete invades the mosquito midgut is one potential approach to developing malaria transmission-blocking strategies. Plasmodium aspartic proteases are one such class of potential targets: plasmepsin IV (known to be present in the asexual stage food vacuole) was previously shown to be involved in Plasmodium gallinaceum infection of the mosquito midgut, and plasmepsins VII and plasmepsin X (not known to be present in the asexual stage food vacuole) are upregulated in Plasmodium falciparum mosquito stages. These (and other) parasite-derived enzymes that play essential roles during ookinete midgut invasion are prime candidates for transmission-blocking vaccines. Reverse transcriptase PCR (RT-PCR) was used to determine timing of P. falciparum plasmepsin VII (PfPM VII) and plasmepsin X (PfPM X) mRNA transcripts in parasite mosquito midgut stages. Protein expression was confirmed by western immunoblot and immunofluorescence assays (IFA) using anti-peptide monoclonal antibodies (mAbs) against immunogenic regions of PfPM VII and PfPM X. These antibodies were also used in standard membrane feeding assays (SMFA) to determine whether inhibition of these proteases would affect parasite transmission to mosquitoes. The Mann-Whitney U test was used to analyse mosquito transmission assay results. RT-PCR, western immunoblot and immunofluorescence assay confirmed expression of PfPM VII and PfPM X in mosquito stages. Whereas PfPM VII was expressed in zygotes and ookinetes, PfPM X was expressed in gametes, zygotes, and ookinetes. Antibodies against PfPM VII and PfPM X decreased P. falciparum invasion of the mosquito midgut when used at high concentrations, indicating that these proteases play a role in Plasmodium mosquito midgut invasion. Failure to generate genetic knockouts of these genes limited determination of the precise role of

  3. Type VII Collagen Expression in the Human Vitreoretinal Interface, Corpora Amylacea and Inner Retinal Layers

    PubMed Central

    Wullink, Bart; Pas, Hendri H.; Van der Worp, Roelofje J.; Kuijer, Roel; Los, Leonoor I.

    2015-01-01

    Type VII collagen, as a major component of anchoring fibrils found at basement membrane zones, is crucial in anchoring epithelial tissue layers to their underlying stroma. Recently, type VII collagen was discovered in the inner human retina by means of immunohistochemistry, while proteomic investigations demonstrated type VII collagen at the vitreoretinal interface of chicken. Because of its potential anchoring function at the vitreoretinal interface, we further assessed the presence of type VII collagen at this site. We evaluated the vitreoretinal interface of human donor eyes by means of immunohistochemistry, confocal microscopy, immunoelectron microscopy, and Western blotting. Firstly, type VII collagen was detected alongside vitreous fibers6 at the vitreoretinal interface. Because of its known anchoring function, it is likely that type VII collagen is involved in vitreoretinal attachment. Secondly, type VII collagen was found within cytoplasmic vesicles of inner retinal cells. These cells resided most frequently in the ganglion cell layer and inner plexiform layer. Thirdly, type VII collagen was found in astrocytic cytoplasmic inclusions, known as corpora amylacea. The intraretinal presence of type VII collagen was confirmed by Western blotting of homogenized retinal preparations. These data add to the understanding of vitreoretinal attachment, which is important for a better comprehension of common vitreoretinal attachment pathologies. PMID:26709927

  4. Optimizing visual comfort for stereoscopic 3D display based on color-plus-depth signals.

    PubMed

    Shao, Feng; Jiang, Qiuping; Fu, Randi; Yu, Mei; Jiang, Gangyi

    2016-05-30

    Visual comfort is a long-facing problem in stereoscopic 3D (S3D) display. In this paper, targeting to produce S3D content based on color-plus-depth signals, a general framework for depth mapping to optimize visual comfort for S3D display is proposed. The main motivation of this work is to remap the depth range of color-plus-depth signals to a new depth range that is suitable to comfortable S3D display. Towards this end, we first remap the depth range globally based on the adjusted zero disparity plane, and then present a two-stage global and local depth optimization solution to solve the visual comfort problem. The remapped depth map is used to generate the S3D output. We demonstrate the power of our approach on perceptually uncomfortable and comfortable stereoscopic images.

  5. Stereoscopically Observing Manipulative Actions

    PubMed Central

    Ferri, S.; Pauwels, K.; Rizzolatti, G.; Orban, G. A.

    2016-01-01

    The purpose of this study was to investigate the contribution of stereopsis to the processing of observed manipulative actions. To this end, we first combined the factors “stimulus type” (action, static control, and dynamic control), “stereopsis” (present, absent) and “viewpoint” (frontal, lateral) into a single design. Four sites in premotor, retro-insular (2) and parietal cortex operated specifically when actions were viewed stereoscopically and frontally. A second experiment clarified that the stereo-action-specific regions were driven by actions moving out of the frontoparallel plane, an effect amplified by frontal viewing in premotor cortex. Analysis of single voxels and their discriminatory power showed that the representation of action in the stereo-action-specific areas was more accurate when stereopsis was active. Further analyses showed that the 4 stereo-action-specific sites form a closed network converging onto the premotor node, which connects to parietal and occipitotemporal regions outside the network. Several of the specific sites are known to process vestibular signals, suggesting that the network combines observed actions in peripersonal space with gravitational signals. These findings have wider implications for the function of premotor cortex and the role of stereopsis in human behavior. PMID:27252350

  6. Use of the stereoscopic virtual reality display system for the detection and characterization of intracranial aneurysms: A Icomparison with conventional computed tomography workstation and 3D rotational angiography.

    PubMed

    Liu, Xiujuan; Tao, Haiquan; Xiao, Xigang; Guo, Binbin; Xu, Shangcai; Sun, Na; Li, Maotong; Xie, Li; Wu, Changjun

    2018-07-01

    This study aimed to compare the diagnostic performance of the stereoscopic virtual reality display system with the conventional computed tomography (CT) workstation and three-dimensional rotational angiography (3DRA) for intracranial aneurysm detection and characterization, with a focus on small aneurysms and those near the bone. First, 42 patients with suspected intracranial aneurysms underwent both 256-row CT angiography (CTA) and 3DRA. Volume rendering (VR) images were captured using the conventional CT workstation. Next, VR images were transferred to the stereoscopic virtual reality display system. Two radiologists independently assessed the results that were obtained using the conventional CT workstation and stereoscopic virtual reality display system. The 3DRA results were considered as the ultimate reference standard. Based on 3DRA images, 38 aneurysms were confirmed in 42 patients. Two cases were misdiagnosed and 1 was missed when the traditional CT workstation was used. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional CT workstation were 94.7%, 85.7%, 97.3%, 75%, and99.3%, respectively, on a per-aneurysm basis. The stereoscopic virtual reality display system missed a case. The sensitivity, specificity, PPV, NPV, and accuracy of the stereoscopic virtual reality display system were 100%, 85.7%, 97.4%, 100%, and 97.8%, respectively. No difference was observed in the accuracy of the traditional CT workstation, stereoscopic virtual reality display system, and 3DRA in detecting aneurysms. The stereoscopic virtual reality display system has some advantages in detecting small aneurysms and those near the bone. The virtual reality stereoscopic vision obtained through the system was found as a useful tool in intracranial aneurysm diagnosis and pre-operative 3D imaging. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. The Trigeminal (V) and Facial (VII) Cranial Nerves

    PubMed Central

    Sanders, Richard D.

    2010-01-01

    There are close functional and anatomical relationships between cranial nerves V and VII in both their sensory and motor divisions. Sensation on the face is innervated by the trigeminal nerves (V) as are the muscles of mastication, but the muscles of facial expression are innervated mainly by the facial nerve (VII) as is the sensation of taste. This article briefly reviews the anatomy of these cranial nerves, disorders of these nerves that are of particular importance to psychiatry, and some considerations for differential diagnosis. PMID:20386632

  8. Parallax Player: a stereoscopic format converter

    NASA Astrophysics Data System (ADS)

    Feldman, Mark H.; Lipton, Lenny

    2003-05-01

    The Parallax Player is a software application that is, in essence, a stereoscopic format converter. Various formats may be inputted and outputted. In addition to being able to take any one of a wide variety of different formats and play them back on many different kinds of PCs and display screens. The Parallax Player has built into it the capability to produce ersatz stereo from a planar still or movie image. The player handles two basic forms of digital content - still images, and movies. It is assumed that all data is digital, either created by means of a photographic film process and later digitized, or directly captured or authored in a digital form. In its current implementation, running on a number of Windows Operating Systems, The Parallax Player reads in a broad selection of contemporary file formats.

  9. (99)Tc(VII) Retardation, Reduction, and Redox Rate Scaling in Naturally Reduced Sediments.

    PubMed

    Liu, Yuanyuan; Liu, Chongxuan; Kukkadapu, Ravi K; McKinley, James P; Zachara, John; Plymale, Andrew E; Miller, Micah D; Varga, Tamas; Resch, Charles T

    2015-11-17

    An experimental and modeling study was conducted to investigate pertechnetate (Tc(VII)O4(-)) retardation, reduction, and rate scaling in three sediments from Ringold formation at U.S. Department of Energy's Hanford site, where (99)Tc is a major contaminant in groundwater. Tc(VII) was reduced in all the sediments in both batch reactors and diffusion columns, with a faster rate in a sediment containing a higher concentration of HCl-extractable Fe(II). Tc(VII) migration in the diffusion columns was reductively retarded with retardation degrees correlated with Tc(VII) reduction rates. The reduction rates were faster in the diffusion columns than those in the batch reactors, apparently influenced by the spatial distribution of redox-reactive minerals along transport paths that supplied Tc(VII). X-ray computed tomography and autoradiography were performed to identify the spatial locations of Tc(VII) reduction and transport paths in the sediments, and results generally confirmed the newly found behavior of reaction rate changes from batch to column. The results from this study implied that Tc(VII) migration can be reductively retarded at Hanford site with a retardation degree dependent on reactive Fe(II) content and its distribution in sediments. This study also demonstrated that an effective reaction rate may be faster in transport systems than that in well-mixed reactors.

  10. Prophylactic treatment of hereditary severe factor VII deficiency in pregnancy.

    PubMed

    Pfrepper, Christian; Siegemund, Annelie; Hildebrandt, Sven; Kronberg, Juliane; Scholz, Ute; Niederwieser, Dietger

    2017-09-01

    : Severe hereditary factor VII deficiency is a rare bleeding disorder and may be associated with a severe bleeding phenotype. We describe a pregnancy in a 33-year-old woman with compound heterozygous factor VII deficiency and a history of severe menorrhagia and mucocutaneous bleedings. After discontinuation of contraceptives, menstruation was covered with recombinant activated factor VII (rFVIIa), and during pregnancy, rFVIIa had to be administered in first trimester in doses ranging from 15 to 90 μg/kg per day because of recurrent retroplacental hematomas and vaginal bleedings. Thrombin generation was measured in first trimester at different doses of rFVIIa and showed an increase in lag time when doses of less than 30 μg/kg/day were administered, whereas time to thrombin peak and peak thrombin were not influenced. A low-dose rFVIIa prophylactic treatment of 15 μg/kg every other day in the late second and in the third trimester was sufficient to allow a successful childbirth in this patient with severe factor VII deficiency.

  11. 76 FR 31892 - Recordkeeping and Reporting Requirements Under Title VII, the ADA, and GINA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ... Requirements Under Title VII, the ADA, and GINA AGENCY: Equal Employment Opportunity Commission. ACTION: Notice...'' or ``Commission'') proposes to extend its existing recordkeeping requirements under title VII of the Civil Rights Act of 1964 (Title VII) and the Americans with Disabilities Act (ADA) to entities covered...

  12. Evaluation of the effectiveness of 3D vascular stereoscopic models in anatomy instruction for first year medical students.

    PubMed

    Cui, Dongmei; Wilson, Timothy D; Rockhold, Robin W; Lehman, Michael N; Lynch, James C

    2017-01-01

    The head and neck region is one of the most complex areas featured in the medical gross anatomy curriculum. The effectiveness of using three-dimensional (3D) models to teach anatomy is a topic of much discussion in medical education research. However, the use of 3D stereoscopic models of the head and neck circulation in anatomy education has not been previously studied in detail. This study investigated whether 3D stereoscopic models created from computed tomographic angiography (CTA) data were efficacious teaching tools for the head and neck vascular anatomy. The test subjects were first year medical students at the University of Mississippi Medical Center. The assessment tools included: anatomy knowledge tests (prelearning session knowledge test and postlearning session knowledge test), mental rotation tests (spatial ability; presession MRT and postsession MRT), and a satisfaction survey. Results were analyzed using a Wilcoxon rank-sum test and linear regression analysis. A total of 39 first year medical students participated in the study. The results indicated that all students who were exposed to the stereoscopic 3D vascular models in 3D learning sessions increased their ability to correctly identify the head and neck vascular anatomy. Most importantly, for students with low-spatial ability, 3D learning sessions improved postsession knowledge scores to a level comparable to that demonstrated by students with high-spatial ability indicating that the use of 3D stereoscopic models may be particularly valuable to these students with low-spatial ability. Anat Sci Educ 10: 34-45. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  13. Effect of neonatal gene therapy on lumbar spine disease in mucopolysaccharidosis VII dogs

    PubMed Central

    Smith, Lachlan J; Martin, John T; O'Donnell, Patricia; Wang, Ping; Elliott, Dawn M; Haskins, Mark E; Ponder, Katherine P

    2012-01-01

    Mucopolysaccharidosis VII (MPS VII) is due to deficient β-glucuronidase (GUSB) activity, which leads to accumulation of chondroitin, heparan, and dermatan sulfate glycosaminoglycans in various tissues including those of the spine. Associated spine disease can be due to abnormalities in the vertebrae, the intervertebral discs, or other spine tissues. The goal of this study was to determine if neonatal gene therapy could prevent lumbar spine disease in MPS VII dogs. MPS VII dogs were injected intravenously with a retroviral vector (RV) expressing canine GUSB at 2 to 3 days after birth, which resulted in transduction of hepatocytes that secreted GUSB into blood. Expression was stable for up to 11 years, and mean survival was increased from 0.4 years in untreated dogs to 6.1 years in treated dogs. Despite a profound positive clinical effect, 6-month-old RV-treated MPS VII dogs still had hypoplastic ventral epiphyses with reduced calcification in the lumbar spine, which resulted in a reduced stiffness and increased range of motion that was not improved relative to untreated MPS VII dogs. At six to 11 years of age, ventral vertebrae remained hypoplastic in RV-treated MPS VII dogs, and there was desiccation of the nucleus pulposus in some discs. Histochemical staining demonstrated that discs did not have detectable GUSB activity despite high serum GUSB activity, which is likely due to poor diffusion into this relatively avascular structure. Thus, neonatal gene therapy cannot prevent lumbar spine disease in MPS VII dogs, which predicts that enzyme replacement therapy (ERT) will similarly be relatively ineffective even if started at birth. PMID:22510705

  14. Effect of neonatal gene therapy on lumbar spine disease in mucopolysaccharidosis VII dogs.

    PubMed

    Smith, Lachlan J; Martin, John T; O'Donnell, Patricia; Wang, Ping; Elliott, Dawn M; Haskins, Mark E; Ponder, Katherine P

    2012-09-01

    Mucopolysaccharidosis VII (MPS VII) is due to deficient β-glucuronidase (GUSB) activity, which leads to accumulation of chondroitin, heparan, and dermatan sulfate glycosaminoglycans in various tissues including those of the spine. Associated spine disease can be due to abnormalities in the vertebrae, the intervertebral disks, or other spine tissues. The goal of this study was to determine if neonatal gene therapy could prevent lumbar spine disease in MPS VII dogs. MPS VII dogs were injected intravenously with a retroviral vector (RV) expressing canine GUSB at 2 to 3 days after birth, which resulted in transduction of hepatocytes that secreted GUSB into blood. Expression was stable for up to 11 years, and mean survival was increased from 0.4 years in untreated dogs to 6.1 years in treated dogs. Despite a profound positive clinical effect, 6-month-old RV-treated MPS VII dogs still had hypoplastic ventral epiphyses with reduced calcification in the lumbar spine, which resulted in a reduced stiffness and increased range of motion that were not improved relative to untreated MPS VII dogs. At six to 11 years of age, ventral vertebrae remained hypoplastic in RV-treated MPS VII dogs, and there was desiccation of the nucleus pulposus in some disks. Histochemical staining demonstrated that disks did not have detectable GUSB activity despite high serum GUSB activity, which is likely due to poor diffusion into this relatively avascular structure. Thus, neonatal gene therapy cannot prevent lumbar spine disease in MPS VII dogs, which predicts that enzyme replacement therapy (ERT) will similarly be relatively ineffective even if started at birth. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. 77 FR 5396 - Recordkeeping and Reporting Requirements Under Title VII, the ADA, and GINA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-03

    ... Requirements Under Title VII, the ADA, and GINA AGENCY: Equal Employment Opportunity Commission. ACTION: Final... rule, extends its existing recordkeeping requirements under title VII of the Civil Rights Act of 1964 (Title VII) and the Americans with Disabilities Act (ADA) to entities covered by title II of the Genetic...

  16. Augmented reality to the rescue of the minimally invasive surgeon. The usefulness of the interposition of stereoscopic images in the Da Vinci™ robotic console.

    PubMed

    Volonté, Francesco; Buchs, Nicolas C; Pugin, François; Spaltenstein, Joël; Schiltz, Boris; Jung, Minoa; Hagen, Monika; Ratib, Osman; Morel, Philippe

    2013-09-01

    Computerized management of medical information and 3D imaging has become the norm in everyday medical practice. Surgeons exploit these emerging technologies and bring information previously confined to the radiology rooms into the operating theatre. The paper reports the authors' experience with integrated stereoscopic 3D-rendered images in the da Vinci surgeon console. Volume-rendered images were obtained from a standard computed tomography dataset using the OsiriX DICOM workstation. A custom OsiriX plugin was created that permitted the 3D-rendered images to be displayed in the da Vinci surgeon console and to appear stereoscopic. These rendered images were displayed in the robotic console using the TilePro multi-input display. The upper part of the screen shows the real endoscopic surgical field and the bottom shows the stereoscopic 3D-rendered images. These are controlled by a 3D joystick installed on the console, and are updated in real time. Five patients underwent a robotic augmented reality-enhanced procedure. The surgeon was able to switch between the classical endoscopic view and a combined virtual view during the procedure. Subjectively, the addition of the rendered images was considered to be an undeniable help during the dissection phase. With the rapid evolution of robotics, computer-aided surgery is receiving increasing interest. This paper details the authors' experience with 3D-rendered images projected inside the surgical console. The use of this intra-operative mixed reality technology is considered very useful by the surgeon. It has been shown that the usefulness of this technique is a step toward computer-aided surgery that will progress very quickly over the next few years. Copyright © 2012 John Wiley & Sons, Ltd.

  17. Virtual and stereoscopic anatomy: when virtual reality meets medical education.

    PubMed

    de Faria, Jose Weber Vieira; Teixeira, Manoel Jacobsen; de Moura Sousa Júnior, Leonardo; Otoch, Jose Pinhata; Figueiredo, Eberval Gadelha

    2016-11-01

    OBJECTIVE The authors sought to construct, implement, and evaluate an interactive and stereoscopic resource for teaching neuroanatomy, accessible from personal computers. METHODS Forty fresh brains (80 hemispheres) were dissected. Images of areas of interest were captured using a manual turntable and processed and stored in a 5337-image database. Pedagogic evaluation was performed in 84 graduate medical students, divided into 3 groups: 1 (conventional method), 2 (interactive nonstereoscopic), and 3 (interactive and stereoscopic). The method was evaluated through a written theory test and a lab practicum. RESULTS Groups 2 and 3 showed the highest mean scores in pedagogic evaluations and differed significantly from Group 1 (p < 0.05). Group 2 did not differ statistically from Group 3 (p > 0.05). Size effects, measured as differences in scores before and after lectures, indicate the effectiveness of the method. ANOVA results showed significant difference (p < 0.05) between groups, and the Tukey test showed statistical differences between Group 1 and the other 2 groups (p < 0.05). No statistical differences between Groups 2 and 3 were found in the practicum. However, there were significant differences when Groups 2 and 3 were compared with Group 1 (p < 0.05). CONCLUSIONS The authors conclude that this method promoted further improvement in knowledge for students and fostered significantly higher learning when compared with traditional teaching resources.

  18. 76 FR 79065 - Recordkeeping and Reporting Requirements Under Title VII, the ADA and GINA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-21

    ... DEPARTMENT OF LABOR Equal Employment Opportunity Commission 29 CFR Part 1602 Recordkeeping and Reporting Requirements Under Title VII, the ADA and GINA CFR Correction In Title 29 of the Code of Federal... title VII or section 107 of the ADA'' and add in their place the words ``section 709(c) of title VII...

  19. Serendipitous Discovery of Factor VII Deficiency and the Ensuing Dilemma.

    PubMed

    Umakanthan, Jayadev M; Dhakal, Prajwal; Gundabolu, Krishna; Koepsell, Scott A; Baljevic, Muhamed

    2018-03-01

    Congenital factor VII deficiency is a challenging disorder to manage, as it is associated with varied genotypes that do not clinically correlate with a bleeding phenotype. Individuals with severe factor VII deficiency (FVII: c <1%) might be asymptomatic, while patients with moderate deficiency (FVII: c level >5%) may experience severe hemorrhages. In modern medicine, due to extensive routine pre-operative laboratory testing, clinically asymptomatic patients without any bleeding history might be incidentally discovered, raising clinical dilemmas. Careful consideration of bleeding versus thrombosis risk has to be made in such cases, especially in the elderly. Clinical history of no prior bleeding complications may be a reassuring factor. Minimal required replacement dosing of recombinant activated factor VII can be given peri-operatively in such situations, with close monitoring.

  20. Altered lumbar spine structure, biochemistry and biomechanical properties in a canine model of mucopolysaccharidosis type VII

    PubMed Central

    Smith, Lachlan J; Martin, John T; Szczesny, Spencer E; Ponder, Katherine P; Haskins, Mark E; Elliott, Dawn M

    2010-01-01

    Mucopolysaccharidosis VII (MPS VII) is a lysosomal storage disorder characterized by a deficiency in β-glucuronidase activity, leading to systemic accumulation of poorly degraded glycosaminoglycans (GAG). Along with other morbidities, MPS VII is associated with paediatric spinal deformity. The objective of this study was to examine potential associations between abnormal lumbar spine matrix structure and composition in MPS VII, and spine segment and tissue-level mechanical properties, using a naturally occurring canine model with a similar clinical phenotype to the human form of the disorder. Segments from juvenile MPS VII and unaffected dogs were allocated to: radiography, gross morphology, histology, biochemistry, and mechanical testing. MPS VII spines had radiolucent lesions in the vertebral body epiphyses. Histologically, this corresponded to a GAG-rich cartilaginous region in place of bone, and elevated GAG staining was seen in the annulus fibrosus. Biochemically, MPS VII samples had elevated GAG in the outer annulus fibrosus and epiphyses, low calcium in the epiphyses, and high water content in all regions except the nucleus pulposus. MPS VII spine segments had higher range of motion and lower stiffness than controls. Endplate indentation stiffness and failure loads were significantly lower in MPS VII samples, while annulus fibrosus tensile mechanical properties were normal. Vertebral body lesions in MPS VII spines suggest a failure to convert cartilage to bone during development. Low stiffness in these regions likely contributes to mechanical weakness in motion segments and is a potential factor in the progression of spinal deformity. PMID:19918911

  1. Field-Sequential Electronic Stereoscopic Projector

    NASA Astrophysics Data System (ADS)

    Lipton, Lenny

    1989-07-01

    Culminating a research and development project spanning many years, StereoGraphics Corporation has succeeded in bringing to market the first field-sequential electronic stereoscopic projector. The product is based on a modification of Electrohome and Barco projectors. Our design goal was to produce a projector capable of displaying an image on a six-foot (or larger) diagonal screen for an audience of 50 or 60 people, or for an individual using a simulator. A second goal was to produce an image that required only passive polarizing glasses rather than powered, tethered visors. Two major design challenges posed themselves. First, it was necessary to create an electro-optical modulator which could switch the characteristic of polarized light at field rate, and second, it was necessary to produce a bright green CRT with short persistence to prevent crosstalk between left and right fields. To solve the first problem, development was undertaken to produce the required electro-optical modulator. The second problem was solved with the help of a vendor specializing in high performance CRT's.

  2. Statis omnidirectional stereoscopic display system

    NASA Astrophysics Data System (ADS)

    Barton, George G.; Feldman, Sidney; Beckstead, Jeffrey A.

    1999-11-01

    A unique three camera stereoscopic omnidirectional viewing system based on the periscopic panoramic camera described in the 11/98 SPIE proceedings (AM13). The 3 panoramic cameras are equilaterally combined so each leg of the triangle approximates the human inter-ocular spacing allowing each panoramic camera to view 240 degree(s) of the panoramic scene, the most counter clockwise 120 degree(s) being the left eye field and the other 120 degree(s) segment being the right eye field. Field definition may be by green/red filtration or time discrimination of the video signal. In the first instance a 2 color spectacle is used in viewing the display or in the 2nd instance LCD goggles are used to differentiate the R/L fields. Radially scanned vidicons or re-mapped CCDs may be used. The display consists of three vertically stacked 120 degree(s) segments of the panoramic field of view with 2 fields/frame. Field A being the left eye display and Field B the right eye display.

  3. Surface topography characterization using 3D stereoscopic reconstruction of SEM images

    NASA Astrophysics Data System (ADS)

    Vedantha Krishna, Amogh; Flys, Olena; Reddy, Vijeth V.; Rosén, B. G.

    2018-06-01

    A major drawback of the optical microscope is its limitation to resolve finer details. Many microscopes have been developed to overcome the limitations set by the diffraction of visible light. The scanning electron microscope (SEM) is one such alternative: it uses electrons for imaging, which have much smaller wavelength than photons. As a result high magnification with superior image resolution can be achieved. However, SEM generates 2D images which provide limited data for surface measurements and analysis. Often many research areas require the knowledge of 3D structures as they contribute to a comprehensive understanding of microstructure by allowing effective measurements and qualitative visualization of the samples under study. For this reason, stereo photogrammetry technique is employed to convert SEM images into 3D measurable data. This paper aims to utilize a stereoscopic reconstruction technique as a reliable method for characterization of surface topography. Reconstructed results from SEM images are compared with coherence scanning interferometer (CSI) results obtained by measuring a roughness reference standard sample. This paper presents a method to select the most robust/consistent surface texture parameters that are insensitive to the uncertainties involved in the reconstruction technique itself. Results from the two-stereoscopic reconstruction algorithms are also documented in this paper.

  4. A foreground object features-based stereoscopic image visual comfort assessment model

    NASA Astrophysics Data System (ADS)

    Jin, Xin; Jiang, G.; Ying, H.; Yu, M.; Ding, S.; Peng, Z.; Shao, F.

    2014-11-01

    Since stereoscopic images provide observers with both realistic and discomfort viewing experience, it is necessary to investigate the determinants of visual discomfort. By considering that foreground object draws most attention when human observing stereoscopic images. This paper proposes a new foreground object based visual comfort assessment (VCA) metric. In the first place, a suitable segmentation method is applied to disparity map and then the foreground object is ascertained as the one having the biggest average disparity. In the second place, three visual features being average disparity, average width and spatial complexity of foreground object are computed from the perspective of visual attention. Nevertheless, object's width and complexity do not consistently influence the perception of visual comfort in comparison with disparity. In accordance with this psychological phenomenon, we divide the whole images into four categories on the basis of different disparity and width, and exert four different models to more precisely predict its visual comfort in the third place. Experimental results show that the proposed VCA metric outperformance other existing metrics and can achieve a high consistency between objective and subjective visual comfort scores. The Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are over 0.84 and 0.82, respectively.

  5. Optoelectronic stereoscopic device for diagnostics, treatment, and developing of binocular vision

    NASA Astrophysics Data System (ADS)

    Pautova, Larisa; Elkhov, Victor A.; Ovechkis, Yuri N.

    2003-08-01

    Operation of the device is based on alternative generation of pictures for left and right eyes on the monitor screen. Controller gives pulses on LCG so that shutter for left or right eye opens synchronously with pictures. The device provides frequency of switching more than 100 Hz, and that is why the flickering is absent. Thus, a separate demonstration of images to the left eye or to the right one in turn is obtained for patients being unaware and creates the conditions of binocular perception clsoe to natural ones without any additional separation of vision fields. LC-cell transfer characteristic coodination with time parameters of monitor screen has enabled to improve stereo image quality. Complicated problem of computer stereo images with LC-glasses is so called 'ghosts' - noise images that come to blocked eye. We reduced its influence by adapting stereo images to phosphor and LC-cells characteristics. The device is intended for diagnostics and treatment of stabismus, amblyopia and other binocular and stereoscopic vision impairments, for cultivating, training and developing of stereoscopic vision, for measurements of horizontal and vertical phoria, phusion reserves, the stereovision acuity and some else, for fixing central scotoma borders, as well as suppression scotoma in strabismus too.

  6. Coagulation factor VII is regulated by androgen receptor in breast cancer.

    PubMed

    Naderi, Ali

    2015-02-01

    Androgen receptor (AR) is widely expressed in breast cancer; however, there is limited information on the key molecular functions and gene targets of AR in this disease. In this study, gene expression data from a cohort of 52 breast cancer cell lines was analyzed to identify a network of AR co-expressed genes. A total of 300 genes, which were significantly enriched for cell cycle and metabolic functions, showed absolute correlation coefficients (|CC|) of more than 0.5 with AR expression across the dataset. In this network, a subset of 35 "AR-signature" genes were highly co-expressed with AR (|CC|>0.6) that included transcriptional regulators PATZ1, NFATC4, and SPDEF. Furthermore, gene encoding coagulation factor VII (F7) demonstrated the closest expression pattern with AR (CC=0.716) in the dataset and factor VII protein expression was significantly associated to that of AR in a cohort of 209 breast tumors. Moreover, functional studies demonstrated that AR activation results in the induction of factor VII expression at both transcript and protein levels and AR directly binds to a proximal region of F7 promoter in breast cancer cells. Importantly, AR activation in breast cancer cells induced endogenous factor VII activity to convert factor X to Xa in conjunction with tissue factor. In summary, F7 is a novel AR target gene and AR activation regulates the ectopic expression and activity of factor VII in breast cancer cells. These findings have functional implications in the pathobiology of thromboembolic events and regulation of factor VII/tissue factor signaling in breast cancer. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. The next phase of Title VII funding for training primary care physicians for America's health care needs.

    PubMed

    Phillips, Robert L; Turner, Barbara J

    2012-01-01

    Health care reform will add millions of Americans to the ranks of the insured; however, their access to health care is threatened by a deep decline in the production of primary care physicians. Poorer access to primary care risks poorer health outcomes and higher costs. Meeting this increased demand requires a major investment in primary care training. Title VII, Section 747 of the Public Health Service Act previously supported the growth of the health care workforce but has been severely cut over the past 2 decades. New and expanded Title VII initiatives are required to increase the production of primary care physicians; establish high-functioning academic, community-based training practices; increase the supply of well-trained primary care faculty; foster innovation and rigorous evaluation of these programs; and ultimately to improve the responsiveness of teaching hospitals to community needs. To accomplish these goals, Congress should act on the Council on Graduate Medical Education's recommendation to increase funding for Title VII, Section 747 roughly 14-fold to $560 million annually. This amount represents a small investment in light of the billions that Medicare currently spends to support graduate medical education, and both should be held to account for meeting physician workforce needs. Expansion of Title VII, Section 747 with the goal of improving access to primary care would be an important part of a needed, broader effort to counter the decline of primary care. Failure to launch such a national primary care workforce revitalization program will put the health and economic viability of our nation at risk.

  8. Photosynthetic pigments of oceanic Chlorophyta belonging to prasinophytes clade VII.

    PubMed

    Lopes Dos Santos, Adriana; Gourvil, Priscillia; Rodríguez, Francisco; Garrido, José Luis; Vaulot, Daniel

    2016-02-01

    The ecological importance and diversity of pico/nanoplanktonic algae remains poorly studied in marine waters, in part because many are tiny and without distinctive morphological features. Amongst green algae, Mamiellophyceae such as Micromonas or Bathycoccus are dominant in coastal waters while prasinophytes clade VII, yet not formerly described, appear to be major players in open oceanic waters. The pigment composition of 14 strains representative of different subclades of clade VII was analyzed using a method that improves the separation of loroxanthin and neoxanthin. All the prasinophytes clade VII analyzed here showed a pigment composition similar to that previously reported for RCC287 corresponding to pigment group prasino-2A. However, we detected in addition astaxanthin for which it is the first report in prasinophytes. Among the strains analyzed, the pigment signature is qualitatively similar within subclades A and B. By contrast, RCC3402 from subclade C (Picocystis) lacks loroxanthin, astaxanthin, and antheraxanthin but contains alloxanthin, diatoxanthin, and monadoxanthin that are usually found in diatoms or cryptophytes. For subclades A and B, loroxanthin was lowest at highest light irradiance suggesting a light-harvesting role of this pigment in clade VII as in Tetraselmis. © 2015 Phycological Society of America.

  9. Title VII Evaluation, 1987-88.

    ERIC Educational Resources Information Center

    Baenen, Nancy R.; Yonan, Barbara

    Title VII federal funds have been used in the Austin (Texas) Independent School District (AISD) since 1985-86 to enhance the regular secondary bilingual and English-as-a-second-language programs for Hispanic limited English proficient (LEP) students. The four secondary campuses involved were those with the highest concentrations of Hispanic LEP…

  10. A novel no-reference objective stereoscopic video quality assessment method based on visual saliency analysis

    NASA Astrophysics Data System (ADS)

    Yang, Xinyan; Zhao, Wei; Ye, Long; Zhang, Qin

    2017-07-01

    This paper proposes a no-reference objective stereoscopic video quality assessment method with the motivation that making the effect of objective experiments close to that of subjective way. We believe that the image regions with different visual salient degree should not have the same weights when designing an assessment metric. Therefore, we firstly use GBVS algorithm to each frame pairs and separate both the left and right viewing images into the regions with strong, general and week saliency. Besides, local feature information like blockiness, zero-crossing and depth are extracted and combined with a mathematical model to calculate a quality assessment score. Regions with different salient degree are assigned with different weights in the mathematical model. Experiment results demonstrate the superiority of our method compared with the existed state-of-the-art no-reference objective Stereoscopic video quality assessment methods.

  11. Onset of ice VII phase during ps laser pulse propagation through liquid water

    NASA Astrophysics Data System (ADS)

    Kumar, V. Rakesh; Kiran, P. Prem

    2017-01-01

    Water dominantly present in liquid state on earth gets transformed to crystalline polymorphs under different dynamic loading conditions. Out of different crystalline phases discovered till date, ice VII is observed to be stable over wide pressure (2-63 GPa) and temperature (>273 K) ranges. The formation of ice VII crystalline structure has been vastly reported during high pressure static compression using diamond anvil cell and propagation of high energy (>50 mJ/pulse) nanosecond laser pulse induced dynamic high pressures through liquid water. We present the onset of ice VII phase at low threshold of 2 mJ/pulse during 30 ps (532 nm, 10 Hz) laser pulse induced shock propagating through liquid water. Role of input pulse energy on the evolution of Stoke's and anti-Stoke's Raman shift of the dominant A1g mode of ice VII, filamentation, free-electrons, plasma shielding is presented. The H-bond network rearrangement, electron ion energy transfer time coinciding with the excitation pulse duration supported by the filamentation and plasma shielding of the ps laser pulses reduced the threshold of ice VII structure formation. Filamentation and the plasma shielding have shown the localized creation and sustenance of ice VII structure in liquid water over 3 mm length and 50 μm area of cross-section.

  12. Stereoscopically Observing Manipulative Actions.

    PubMed

    Ferri, S; Pauwels, K; Rizzolatti, G; Orban, G A

    2016-08-01

    The purpose of this study was to investigate the contribution of stereopsis to the processing of observed manipulative actions. To this end, we first combined the factors "stimulus type" (action, static control, and dynamic control), "stereopsis" (present, absent) and "viewpoint" (frontal, lateral) into a single design. Four sites in premotor, retro-insular (2) and parietal cortex operated specifically when actions were viewed stereoscopically and frontally. A second experiment clarified that the stereo-action-specific regions were driven by actions moving out of the frontoparallel plane, an effect amplified by frontal viewing in premotor cortex. Analysis of single voxels and their discriminatory power showed that the representation of action in the stereo-action-specific areas was more accurate when stereopsis was active. Further analyses showed that the 4 stereo-action-specific sites form a closed network converging onto the premotor node, which connects to parietal and occipitotemporal regions outside the network. Several of the specific sites are known to process vestibular signals, suggesting that the network combines observed actions in peripersonal space with gravitational signals. These findings have wider implications for the function of premotor cortex and the role of stereopsis in human behavior. © The Author 2016. Published by Oxford University Press.

  13. Adenovirus Core Protein VII Downregulates the DNA Damage Response on the Host Genome

    PubMed Central

    Avgousti, Daphne C.; Della Fera, Ashley N.; Otter, Clayton J.; Herrmann, Christin; Pancholi, Neha J.

    2017-01-01

    ABSTRACT Viral manipulation of cellular proteins allows viruses to suppress host defenses and generate infectious progeny. Due to the linear double-stranded DNA nature of the adenovirus genome, the cellular DNA damage response (DDR) is considered a barrier to successful infection. The adenovirus genome is packaged with protein VII, a virally encoded histone-like core protein that is suggested to protect incoming viral genomes from detection by the cellular DNA damage machinery. We showed that protein VII localizes to host chromatin during infection, leading us to hypothesize that protein VII may affect DNA damage responses on the cellular genome. Here we show that protein VII at cellular chromatin results in a significant decrease in accumulation of phosphorylated H2AX (γH2AX) following irradiation, indicating that protein VII inhibits DDR signaling. The oncoprotein SET was recently suggested to modulate the DDR by affecting access of repair proteins to chromatin. Since protein VII binds SET, we investigated a role for SET in DDR inhibition by protein VII. We show that knockdown of SET partially rescues the protein VII-induced decrease in γH2AX accumulation on the host genome, suggesting that SET is required for inhibition. Finally, we show that knockdown of SET also allows ATM to localize to incoming viral genomes bound by protein VII during infection with a mutant lacking early region E4. Together, our data suggest that the protein VII-SET interaction contributes to DDR evasion by adenovirus. Our results provide an additional example of a strategy used by adenovirus to abrogate the host DDR and show how viruses can modify cellular processes through manipulation of host chromatin. IMPORTANCE The DNA damage response (DDR) is a cellular network that is crucial for maintaining genome integrity. DNA viruses replicating in the nucleus challenge the resident genome and must overcome cellular responses, including the DDR. Adenoviruses are prevalent human pathogens that

  14. Passive method of eliminating accommodation/convergence disparity in stereoscopic head-mounted displays

    NASA Astrophysics Data System (ADS)

    Eichenlaub, Jesse B.

    2005-03-01

    The difference in accommodation and convergence distance experienced when viewing stereoscopic displays has long been recognized as a source of visual discomfort. It is especially problematic in head mounted virtual reality and enhanced reality displays, where images must often be displayed across a large depth range or superimposed on real objects. DTI has demonstrated a novel method of creating stereoscopic images in which the focus and fixation distances are closely matched for all parts of the scene from close distances to infinity. The method is passive in the sense that it does not rely on eye tracking, moving parts, variable focus optics, vibrating optics, or feedback loops. The method uses a rapidly changing illumination pattern in combination with a high speed microdisplay to create cones of light that converge at different distances to form the voxels of a high resolution space filling image. A bench model display was built and a series of visual tests were performed in order to demonstrate the concept and investigate both its capabilities and limitations. Results proved conclusively that real optical images were being formed and that observers had to change their focus to read text or see objects at different distances

  15. Stereoscopic display technologies for FHD 3D LCD TV

    NASA Astrophysics Data System (ADS)

    Kim, Dae-Sik; Ko, Young-Ji; Park, Sang-Moo; Jung, Jong-Hoon; Shestak, Sergey

    2010-04-01

    Stereoscopic display technologies have been developed as one of advanced displays, and many TV industrials have been trying commercialization of 3D TV. We have been developing 3D TV based on LCD with LED BLU (backlight unit) since Samsung launched the world's first 3D TV based on PDP. However, the data scanning of panel and LC's response characteristics of LCD TV cause interference among frames (that is crosstalk), and this makes 3D video quality worse. We propose the method to reduce crosstalk by LCD driving and backlight control of FHD 3D LCD TV.

  16. 40 CFR Appendix Vii to Part 86 - Standard Bench Cycle (SBC)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... VII Appendix VII to Part 86—Standard Bench Cycle (SBC) 1. The standard bench aging durability procedures [Ref. § 86.1823-08(d)] consist of aging a catalyst-oxygen-sensor system on an aging bench which follows the standard bench cycle (SBC) described in this appendix. 2. The SBC requires use of an aging...

  17. 40 CFR Appendix Vii to Part 86 - Standard Bench Cycle (SBC)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... VII Appendix VII to Part 86—Standard Bench Cycle (SBC) 1. The standard bench aging durability procedures [Ref. § 86.1823-08(d)] consist of aging a catalyst-oxygen-sensor system on an aging bench which follows the standard bench cycle (SBC) described in this appendix. 2. The SBC requires use of an aging...

  18. Stereoscopic Vascular Models of the Head and Neck: A Computed Tomography Angiography Visualization

    ERIC Educational Resources Information Center

    Cui, Dongmei; Lynch, James C.; Smith, Andrew D.; Wilson, Timothy D.; Lehman, Michael N.

    2016-01-01

    Computer-assisted 3D models are used in some medical and allied health science schools; however, they are often limited to online use and 2D flat screen-based imaging. Few schools take advantage of 3D stereoscopic learning tools in anatomy education and clinically relevant anatomical variations when teaching anatomy. A new approach to teaching…

  19. Matching methods evaluation framework for stereoscopic breast x-ray images.

    PubMed

    Rousson, Johanna; Naudin, Mathieu; Marchessoux, Cédric

    2016-01-01

    Three-dimensional (3-D) imaging has been intensively studied in the past few decades. Depth information is an important added value of 3-D systems over two-dimensional systems. Special focuses were devoted to the development of stereo matching methods for the generation of disparity maps (i.e., depth information within a 3-D scene). Dedicated frameworks were designed to evaluate and rank the performance of different stereo matching methods but never considering x-ray medical images. Yet, 3-D x-ray acquisition systems and 3-D medical displays have already been introduced into the diagnostic market. To access the depth information within x-ray stereoscopic images, computing accurate disparity maps is essential. We aimed at developing a framework dedicated to x-ray stereoscopic breast images used to evaluate and rank several stereo matching methods. A multiresolution pyramid optimization approach was integrated to the framework to increase the accuracy and the efficiency of the stereo matching techniques. Finally, a metric was designed to score the results of the stereo matching compared with the ground truth. Eight methods were evaluated and four of them [locally scaled sum of absolute differences (LSAD), zero mean sum of absolute differences, zero mean sum of squared differences, and locally scaled mean sum of squared differences] appeared to perform equally good with an average error score of 0.04 (0 is the perfect matching). LSAD was selected for generating the disparity maps.

  20. Factor VII deficiency: a novel missense variant and genotype-phenotype correlation in patients from Southern Italy.

    PubMed

    Tiscia, Giovanni; Favuzzi, Giovanni; Chinni, Elena; Colaizzo, Donatella; Fischetti, Lucia; Intrieri, Mariano; Margaglione, Maurizio; Grandone, Elvira

    2017-01-01

    This study aimed at attempting to correlate genotype and phenotype in factor VII deficiency. Here, we present molecular and clinical findings of 10 patients with factor VII deficiency. From 2013 to 2016, 10 subjects were referred to our center because of a prolonged prothrombin time identified during routine or presurgery examinations or after a laboratory assessment of a bleeding episode. Mutation characterization was performed using the bioinformatics applications PROMO, SIFT, and Polyphen-2. Structural changes in the factor VII protein were analyzed using the SPDB viewer tool. Of the 10 variants we identified, 1 was responsible for a novel missense change (c.1199G>C, p.Cys400Ser); in 2 cases we identified the c.-54G>A and c.509G>A (p.Arg170His) polymorphic variants in the 5'-upstream region of the factor VII gene and exon 6, respectively. To our knowledge, neither of these polymorphic variants has been described previously in factor VII-deficient patients. In silico predictions showed differences in binding sites for transcription factors caused by the c.-54G>A variant and a probable damaging effect of the p.Cys400Ser missense change on factor VII active conformation, leading to breaking of the Cys400-Cys428 disulfide bridge. Our findings further suggest that, independently of factor VII levels and of variants potentially affecting factor VII levels, environmental factors, e.g., trauma, could heavily influence the clinical phenotype of factor VII-deficient patients.

  1. Self-production of tissue factor-coagulation factor VII complex by ovarian cancer cells.

    PubMed

    Yokota, N; Koizume, S; Miyagi, E; Hirahara, F; Nakamura, Y; Kikuchi, K; Ruf, W; Sakuma, Y; Tsuchiya, E; Miyagi, Y

    2009-12-15

    Thromboembolic events are a major complication in ovarian cancer patients. Tissue factor (TF) is frequently overexpressed in ovarian cancer tissue and correlates with intravascular thrombosis. TF binds to coagulation factor VII (fVII), changing it to its active form, fVIIa. This leads to activation of the extrinsic coagulation cascade. fVII is produced by the liver and believed to be supplied from blood plasma at the site of coagulation. However, we recently showed that ovarian cancer cells express fVII transcripts under normoxia and that this transcription is inducible under hypoxia. These findings led us to hypothesise that ovarian cancer cells are intrinsically associated with TF-fVIIa coagulation activity, which could result in thrombosis. In this study, we examined whether ectopically expressed fVII could cause thrombosis by means of immunohistochemistry, RT-PCR, western blotting and flow cytometry. Ectopic fVII expression occurs frequently in ovarian cancers, particularly in clear cell carcinoma. We further showed that ovarian cancer cells express TF-fVIIa on the cell surface under normoxia and that this procoagulant activity is enhanced by hypoxic stimuli. Moreover, we showed that ovarian cancer cells secrete microparticles (MPs) with TF-fVIIa activity. Production of this procoagulant secretion is enhanced under hypoxia. These results raise the possibility that cancer cell-derived TF-fVIIa could cause thrombotic events in ovarian cancer patients.

  2. Impact of Title VII Training Programs on Community Health Center Staffing and National Health Service Corps Participation

    PubMed Central

    Rittenhouse, Diane R.; Fryer, George E.; Phillips, Robert L.; Miyoshi, Thomas; Nielsen, Christine; Goodman, David C.; Grumbach, Kevin

    2008-01-01

    PURPOSE Community health centers (CHCs) are a critical component of the health care safety net. President Bush’s recent effort to expand CHC capacity coincides with difficulty recruiting primary care physicians and substantial cuts in federal grant programs designed to prepare and motivate physicians to practice in underserved settings. This article examines the association between physicians’ attendance in training programs funded by Health Resources and Services Administration (HRSA) Title VII Section 747 Primary Care Training Grants and 2 outcome variables: work in a CHC and participation in the National Health Service Corps Loan Repayment Program (NHSC LRP). METHODS We linked the 2004 American Medical Association Physician Master-file to HRSA Title VII grants files, Medicare claims data, and data from the NHSC. We then conducted retrospective analyses to compare the proportions of physicians working in CHCs among physicians who either had or had not attended Title VII–funded medical schools or residency programs and to determine the association between having attended Title VII–funded residency programs and subsequent NHSC LRP participation. RESULTS Three percent (5,934) of physicians who had attended Title VII–funded medical schools worked in CHCs in 2001–2003, compared with 1.9% of physicians who attended medical schools without Title VII funding (P<.001). We found a similar association between Title VII funding during residency and subsequent work in CHCs. These associations remained significant (P<.001) in logistic regression models controlling for NHSC participation, public vs private medical school, residency completion date, and physician sex. A strong association was also found between attending Title VII–funded residency programs and participation in the NHSC LRP, controlling for year completed training, physician sex, and private vs public medical school. CONCLUSIONS Continued federal support of Title VII training grant programs is

  3. The Effects of Actual Human Size Display and Stereoscopic Presentation on Users' Sense of Being Together with and of Psychological Immersion in a Virtual Character

    PubMed Central

    Ahn, Dohyun; Seo, Youngnam; Kim, Minkyung; Kwon, Joung Huem; Jung, Younbo; Ahn, Jungsun

    2014-01-01

    Abstract This study examined the role of display size and mode in increasing users' sense of being together with and of their psychological immersion in a virtual character. Using a high-resolution three-dimensional virtual character, this study employed a 2×2 (stereoscopic mode vs. monoscopic mode×actual human size vs. small size display) factorial design in an experiment with 144 participants randomly assigned to each condition. Findings showed that stereoscopic mode had a significant effect on both users' sense of being together and psychological immersion. However, display size affected only the sense of being together. Furthermore, display size was not found to moderate the effect of stereoscopic mode. PMID:24606057

  4. Delayed hypertrophic differentiation of epiphyseal chondrocytes contributes to failed secondary ossification in mucopolysaccharidosis VII dogs

    PubMed Central

    Peck, Sun H.; O'Donnell, Philip J.M.; Kang, Jennifer L.; Malhotra, Neil R.; Dodge, George R.; Pacifici, Maurizio; Shore, Eileen M.; Haskins, Mark E.; Smith, Lachlan J.

    2015-01-01

    Mucopolysaccharidosis (MPS) VII is a lysosomal storage disorder characterized by deficient β-glucuronidase activity, which leads to the accumulation of incompletely degraded glycosaminoglycans (GAGs). MPS VII patients present with severe skeletal abnormalities, which are particularly prevalent in the spine. Incomplete cartilage-to-bone conversion in MPS VII vertebrae during postnatal development is associated with progressive spinal deformity and spinal cord compression. The objectives of this study were to determine the earliest postnatal developmental stage at which vertebral bone disease manifests in MPS VII and to identify the underlying cellular basis of impaired cartilage-to-bone conversion, using the naturally-occurring canine model. Control and MPS VII dogs were euthanized at 9 and 14 days-of-age, and vertebral secondary ossification centers analyzed using micro-computed tomography, histology, qPCR, and protein immunoblotting. Imaging studies and mRNA analysis of bone formation markers established that secondary ossification commences between 9 and 14 days in control animals, but not in MPS VII animals. mRNA analysis of differentiation markers revealed that MPS VII epiphyseal chondrocytes are unable to successfully transition from proliferation to hypertrophy during this critical developmental window. Immunoblotting demonstrated abnormal persistence of Sox9 protein in MPS VII cells between 9 and 14 days-of-age, and biochemical assays revealed abnormally high intra and extracellular GAG content in MPS VII epiphyseal cartilage at as early as 9 days-of-age. In contrast, assessment of vertebral growth plates and primary ossification centers revealed no significant abnormalities at either age. The results of this study establish that failed vertebral bone formation in MPS VII can be traced to the failure of epiphyseal chondrocytes to undergo hypertrophic differentiation at the appropriate developmental stage, and suggest that aberrant processing of Sox9 protein

  5. The Next Phase of Title VII Funding for Training Primary Care Physicians for America’s Health Care Needs

    PubMed Central

    Phillips, Robert L.; Turner, Barbara J.

    2012-01-01

    Health care reform will add millions of Americans to the ranks of the insured; however, their access to health care is threatened by a deep decline in the production of primary care physicians. Poorer access to primary care risks poorer health outcomes and higher costs. Meeting this increased demand requires a major investment in primary care training. Title VII, Section 747 of the Public Health Service Act previously supported the growth of the health care workforce but has been severely cut over the past 2 decades. New and expanded Title VII initiatives are required to increase the production of primary care physicians; establish high-functioning academic, community-based training practices; increase the supply of well-trained primary care faculty; foster innovation and rigorous evaluation of these programs; and ultimately to improve the responsiveness of teaching hospitals to community needs. To accomplish these goals, Congress should act on the Council on Graduate Medical Education’s recommendation to increase funding for Title VII, Section 747 roughly 14-fold to $560 million annually. This amount represents a small investment in light of the billions that Medicare currently spends to support graduate medical education, and both should be held to account for meeting physician workforce needs. Expansion of Title VII, Section 747 with the goal of improving access to primary care would be an important part of a needed, broader effort to counter the decline of primary care. Failure to launch such a national primary care workforce revitalization program will put the health and economic viability of our nation at risk. PMID:22412009

  6. 29 CFR 1604.8 - Relationship of title VII to the Equal Pay Act.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... GUIDELINES ON DISCRIMINATION BECAUSE OF SEX § 1604.8 Relationship of title VII to the Equal Pay Act. (a) The employee coverage of the prohibitions against discrimination based on sex contained in title VII is...

  7. Clinical Assessment of Stereoacuity and 3-D Stereoscopic Entertainment

    PubMed Central

    Tidbury, Laurence P.; Black, Robert H.; O’Connor, Anna R.

    2015-01-01

    Abstract Background/Aims: The perception of compelling depth is often reported in individuals where no clinically measurable stereoacuity is apparent. We aim to investigate the potential cause of this finding by varying the amount of stereopsis available to the subject, and assessing their perception of depth viewing 3-D video clips and a Nintendo 3DS. Methods: Monocular blur was used to vary interocular VA difference, consequently creating 4 levels of measurable binocular deficit from normal stereoacuity to suppression. Stereoacuity was assessed at each level using the TNO, Preschool Randot®, Frisby, the FD2, and Distance Randot®. Subjects also completed an object depth identification task using the Nintendo 3DS, a static 3DTV stereoacuity test, and a 3-D perception rating task of 6 video clips. Results: As intraocular VA differences increased, stereoacuity of the 57 subjects (aged 16–62 years) decreased (eg, 110”, 280”, 340”, and suppression). The ability to correctly identify depth on the Nintendo 3DS remained at 100% until suppression of one eye occurred. The perception of a compelling 3-D effect when viewing the video clips was rated high until suppression of one eye occurred, where the 3-D effect was still reported as fairly evident. Conclusion: If an individual has any level of measurable stereoacuity, the perception of 3-D when viewing stereoscopic entertainment is present. The presence of motion in stereoscopic video appears to provide cues to depth, where static cues are not sufficient. This suggests there is a need for a dynamic test of stereoacuity to be developed, to allow fully informed patient management decisions to be made. PMID:26669421

  8. Trade-offs arising from mixture of color cueing and monocular, binoptic, and stereoscopic cueing information for simulated rotorcraft flight

    NASA Technical Reports Server (NTRS)

    Parrish, Russell V.; Williams, Steven P.

    1993-01-01

    To provide stereopsis, binocular helmet-mounted display (HMD) systems must trade some of the total field of view available from their two monocular fields to obtain a partial overlap region. The visual field then provides a mixture of cues, with monocular regions on both peripheries and a binoptic (the same image in both eyes) region or, if lateral disparity is introduced to produce two images, a stereoscopic region in the overlapped center. This paper reports on in-simulator assessment of the trade-offs arising from the mixture of color cueing and monocular, binoptic, and stereoscopic cueing information in peripheral monitoring displays as utilized in HMD systems. The accompanying effect of stereoscopic cueing in the tracking information in the central region of the display is also assessed. The pilot's task for the study was to fly at a prescribed height above an undulating pathway in the sky while monitoring a dynamic bar chart displayed in the periphery of their field of view. Control of the simulated rotorcraft was limited to the longitudinal and vertical degrees of freedom to ensure the lateral separation of the viewing conditions of the concurrent tasks.

  9. New isochromophilones VII and VIII produced by Penicillium sp. FO-4164.

    PubMed

    Yang, D J; Tomoda, H; Tabata, N; Masuma, R; Omura, S

    1996-03-01

    New isochromophilones VII and VIII were isolated from the culture broth of Penicillium sp. FO-4164. The structures were elucidated as 6H-2-benzopyran-6,8(7H)-dione, 5-chloro-3-(3',5'-dimethyl-1',3'-heptadienyl)-1,7,8a-trihydro-7, 8a-dihydroxy-7-methyl-7-acetate for isochromophilone VII and 6H-2-benzopyran-6-one,5-chloro-3-(3',5'-dimethyl-1', 3'-heptadienyl)-1,7,8,8a-tetrahydro-7,8-dihydroxy-7-methyl-8-acetate for isochromophilone VIII. Isochromophilones VII and VIII inhibited diacylglycerol acyltransferase activity with IC50 values of 20.0 and 127 microM and acyl-CoA: cholesterol acyltransferase activity with IC50 values of 24.5 and 47.0 microM, respectively.

  10. The Effect of Stereoscopic ("3D") vs. 2D Presentation on Learning through Video and Film

    NASA Astrophysics Data System (ADS)

    Price, Aaron; Kasal, E.

    2014-01-01

    Two Eyes, 3D is a NSF-funded research project into the effects of stereoscopy on learning of highly spatial concepts. We report final results on one study of the project which tested the effect of stereoscopic presentation on learning outcomes of two short films about Type 1a supernovae and the morphology of the Milky Way. 986 adults watched either film, randomly distributed between stereoscopic and 2D presentation. They took a pre-test and post-test that included multiple choice and drawing tasks related to the spatial nature of the topics in the film. Orientation of the answering device was also tracked and a spatial cognition pre-test was given to control for prior spatial ability. Data collection took place at the Adler Planetarium's Space Visualization Lab and the project is run through the AAVSO.

  11. Onset of ice VII phase during ps laser pulse propagation through liquid water

    NASA Astrophysics Data System (ADS)

    Paturi, Prem Kiran; Vaddapally, Rakesh Kumar; Acrhem Team

    2015-06-01

    Water dominantly present in liquid state on earth gets transformed to crystalline polymorphs under different dynamic loading conditions. Out of 15 different crystalline phases discovered till date, ice VII is observed to be stable over wide pressure (2-63 GPa) and temperature (>273 K) ranges. We present the onset of ice VII phase at low threshold of 2 mJ/pulse during 30 ps (532 nm, 10 Hz) laser pulse induced shock propagating through liquid water. Role of input pulse energy on the evolution of Stoke's and anti-Stoke's Raman shift of the dominant A1g mode of ice VII, filamentation, free-electrons, plasma shielding is presented. The H-bond network rearrangement, electron ion energy transfer time coinciding with the excitation pulse duration supported by the filamentation and plasma shielding of the ps laser pulses reduced the threshold of ice VII structure formation. Filamentation and the plasma shielding have shown the localized creation and sustenance of ice VII structure in liquid water over 3 mm length and 50 μm area of cross-section. The work is supported by Defence Research and Developement Organization, India through Grants-in-Aid Program.

  12. The preparation and structure of salty ice VII under pressure

    NASA Astrophysics Data System (ADS)

    Klotz, Stefan; Bove, Livia E.; Strässle, Thierry; Hansen, Thomas C.; Saitta, Antonino M.

    2009-05-01

    It is widely accepted that ice, no matter what phase, is unable to incorporate large amounts of salt into its structure. This conclusion is based on the observation that on freezing of salt water, ice expels the salt almost entirely as brine. Here, we show that this behaviour is not an intrinsic physico-chemical property of ice phases. We demonstrate by neutron diffraction that substantial amounts of dissolved LiCl can be built homogeneously into the ice VII structure if it is produced by recrystallization of its glassy (amorphous) state under pressure. Such `alloyed' ice VII has significantly different structural properties compared with pure ice VII, such as an 8% larger unit cell volume, 5 times larger displacement factors, an absence of a transition to an ordered ice VIII structure and plasticity. Our study suggests that there could be a whole new class of `salty' high-pressure ice forms.

  13. The preparation and structure of salty ice VII under pressure.

    PubMed

    Klotz, Stefan; Bove, Livia E; Strässle, Thierry; Hansen, Thomas C; Saitta, Antonino M

    2009-05-01

    It is widely accepted that ice, no matter what phase, is unable to incorporate large amounts of salt into its structure. This conclusion is based on the observation that on freezing of salt water, ice expels the salt almost entirely as brine. Here, we show that this behaviour is not an intrinsic physico-chemical property of ice phases. We demonstrate by neutron diffraction that substantial amounts of dissolved LiCl can be built homogeneously into the ice VII structure if it is produced by recrystallization of its glassy (amorphous) state under pressure. Such 'alloyed' ice VII has significantly different structural properties compared with pure ice VII, such as an 8% larger unit cell volume, 5 times larger displacement factors, an absence of a transition to an ordered ice VIII structure and plasticity. Our study suggests that there could be a whole new class of 'salty' high-pressure ice forms.

  14. Correction of murine mucopolysaccharidosis VII by a human. beta. -glucuronidase transgene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kyle, J.W.; Vogler, C.; Hoffmann, J.W.

    1990-05-01

    The authors recently described a murine model for mucopolysaccharidosis VII in mice that have an inherited deficiency of {beta}-glucuronidase. Affected mice, of genotype gus{sup mps}/gus{sup mps}, present clinical manifestations similar to those of humans with mucopolysaccharidosis VII (Sly syndrome) and are shown here to have secondary elevations of other lysosomal enzymes. The mucopolysaccharidosis VII phenotype in both species includes dwarfism, skeletal deformities, and premature death. Lysosome storage is visualized within enlarged vesicles and correlates biochemically with accumulation of undegraded and partially degraded glycosaminoglycans. In this report they describe the consequences of introducing the human {beta}-glucuronidase gene, GUSB, into gus{sup mps}/gus{supmore » mps} mice that produce virtually no murine {beta}-glucuronidase. Transgenic mice homozygous for the mucopolysaccharidosis VII mutation expressed high levels of human {beta}-glucuronidase activity in all tissues examined and were phenotypically normal. Biochemically, both the intralysosomal storage of glycosaminoglycans and the secondary elevation of other acid hydrolases were corrected. These findings demonstrate that the GUSB transgene is expressed in gus{sup mps}/gus{sup mps} mice and that human {beta}-glucuronidase corrects the murine mucopolysaccharidosis storage disease.« less

  15. The Impact of Stereoscopic Imagery and Motion on Anatomical Structure Recognition and Visual Attention Performance

    ERIC Educational Resources Information Center

    Remmele, Martin; Schmidt, Elena; Lingenfelder, Melissa; Martens, Andreas

    2018-01-01

    Gross anatomy is located in a three-dimensional space. Visualizing aspects of structures in gross anatomy education should aim to provide information that best resembles their original spatial proportions. Stereoscopic three-dimensional imagery might offer possibilities to implement this aim, though some research has revealed potential impairments…

  16. Broadcast-quality-stereoscopic video in a time-critical entertainment and corporate environment

    NASA Astrophysics Data System (ADS)

    Gay, Jean-Philippe

    1995-03-01

    `reality present: Peter Gabrial and Cirque du Soleil' is a 12 minute original work directed and produced by Doug Brown, Jean-Philippe Gay & A. Coogan, which showcases creative content applications of commercial stereoscopic video equipment. For production, a complete equipment package including a Steadicam mount was used in support of the Ikegami LK-33 camera. Remote production units were fielded in the time critical, on-stage and off-stage environments of 2 major live concerts: Peter Gabriel's Secret World performance at the San Diego Sports Arena, and Cirque du Soleil's Saltimbanco performance in Chicago. Twin 60 Hz video channels were captured on Beta SP for maximum post production flexibility. Digital post production and field sequential mastering were effected in D-2 format at studio facilities in Los Angeles. The program was world premiered to a large public at the World of Music, Arts and Dance festivals in Los Angeles and San Francisco, in late 1993. It was presented to the artists in Los Angeles, Montreal and Washington D.C. Additional presentations have been made using a broad range of commercial and experimental stereoscopic video equipment, including projection systems, LCD and passive eyewear, and digital signal processors. Technical packages for live presentation have been fielded on site and off, through to the present.

  17. Stereoscopic 3D entertainment and its effect on viewing comfort: comparison of children and adults.

    PubMed

    Pölönen, Monika; Järvenpää, Toni; Bilcu, Beatrice

    2013-01-01

    Children's and adults' viewing comfort during stereoscopic three-dimensional film viewing and computer game playing was studied. Certain mild changes in visual function, heterophoria and near point of accommodation values, as well as eyestrain and visually induced motion sickness levels were found when single setups were compared. The viewing system had an influence on viewing comfort, in particular for eyestrain levels, but no clear difference between two- and three-dimensional systems was found. Additionally, certain mild changes in visual functions and visually induced motion sickness levels between adults and children were found. In general, all of the system-task combinations caused mild eyestrain and possible changes in visual functions, but these changes in magnitude were small. According to subjective opinions that further support these measurements, using a stereoscopic three-dimensional system for up to 2 h was acceptable for most of the users regardless of their age. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  18. Effects of Recombinant Activated Factor VII in Traumatic Nonsurgical Intracranial Hemorrhage

    DTIC Science & Technology

    2006-09-01

    with inhibitors to factors VIII and IX, and it is ap- proved in Europe for the treatment of patients with acquired hemophilia, congenital FVII deficiency...GARY P. WRATTEN SURGICAL SYMPOSIUM Effects of Recombinant Activated Factor VII in Traumatic Nonsurgical Intracranial Hemorrhage Christopher E. White...OBJECTIVE: To determine whether treatment with recombi- nant activated factor VII (rFVIIa) will prevent progression of bleeding in nonsurgical

  19. Stereoscopic neuroanatomy lectures using a three-dimensional virtual reality environment.

    PubMed

    Kockro, Ralf A; Amaxopoulou, Christina; Killeen, Tim; Wagner, Wolfgang; Reisch, Robert; Schwandt, Eike; Gutenberg, Angelika; Giese, Alf; Stofft, Eckart; Stadie, Axel T

    2015-09-01

    Three-dimensional (3D) computer graphics are increasingly used to supplement the teaching of anatomy. While most systems consist of a program which produces 3D renderings on a workstation with a standard screen, the Dextrobeam virtual reality VR environment allows the presentation of spatial neuroanatomical models to larger groups of students through a stereoscopic projection system. Second-year medical students (n=169) were randomly allocated to receive a standardised pre-recorded audio lecture detailing the anatomy of the third ventricle accompanied by either a two-dimensional (2D) PowerPoint presentation (n=80) or a 3D animated tour of the third ventricle with the DextroBeam. Students completed a 10-question multiple-choice exam based on the content learned and a subjective evaluation of the teaching method immediately after the lecture. Students in the 2D group achieved a mean score of 5.19 (±2.12) compared to 5.45 (±2.16) in the 3D group, with the results in the 3D group statistically non-inferior to those of the 2D group (p<0.0001). The students rated the 3D method superior to 2D teaching in four domains (spatial understanding, application in future anatomy classes, effectiveness, enjoyableness) (p<0.01). Stereoscopically enhanced 3D lectures are valid methods of imparting neuroanatomical knowledge and are well received by students. More research is required to define and develop the role of large-group VR systems in modern neuroanatomy curricula. Copyright © 2015 Elsevier GmbH. All rights reserved.

  20. Full-color stereoscopic single-pixel camera based on DMD technology

    NASA Astrophysics Data System (ADS)

    Salvador-Balaguer, Eva; Clemente, Pere; Tajahuerce, Enrique; Pla, Filiberto; Lancis, Jesús

    2017-02-01

    Imaging systems based on microstructured illumination and single-pixel detection offer several advantages over conventional imaging techniques. They are an effective method for imaging through scattering media even in the dynamic case. They work efficiently under low light levels, and the simplicity of the detector makes it easy to design imaging systems working out of the visible spectrum and to acquire multidimensional information. In particular, several approaches have been proposed to record 3D information. The technique is based on sampling the object with a sequence of microstructured light patterns codified onto a programmable spatial light modulator while light intensity is measured with a single-pixel detector. The image is retrieved computationally from the photocurrent fluctuations provided by the detector. In this contribution we describe an optical system able to produce full-color stereoscopic images by using few and simple optoelectronic components. In our setup we use an off-the-shelf digital light projector (DLP) based on a digital micromirror device (DMD) to generate the light patterns. To capture the color of the scene we take advantage of the codification procedure used by the DLP for color video projection. To record stereoscopic views we use a 90° beam splitter and two mirrors, allowing us two project the patterns form two different viewpoints. By using a single monochromatic photodiode we obtain a pair of color images that can be used as input in a 3-D display. To reduce the time we need to project the patterns we use a compressive sampling algorithm. Experimental results are shown.

  1. Gene disruption reveals a dispensable role for plasmepsin VII in the Plasmodium berghei life cycle.

    PubMed

    Mastan, Babu S; Kumari, Anchala; Gupta, Dinesh; Mishra, Satish; Kumar, Kota Arun

    2014-06-01

    Plasmepsins (PM), aspartic proteases of Plasmodium, comprises a family of ten proteins that perform critical functions in Plasmodium life cycle. Except VII and VIII, functions of the remaining plasmepsin members have been well characterized. Here, we have generated a mutant parasite lacking PM VII in Plasmodium berghei using reverse genetics approach. Systematic comparison of growth kinetics and infection in both mosquito and vertebrate host revealed that PM VII depleted mutants exhibited no defects in development and progressed normally throughout the parasite life cycle. These studies suggest a dispensable role for PM VII in Plasmodium berghei life cycle. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Effects of Stereoscopic 3D Digital Radar Displays on Air Traffic Controller Performance

    DTIC Science & Technology

    2013-03-01

    between men and women , but no significant influence was found. Experience in ATC was considered as a potential covariate that would be presumed to have...depicts altitude through the use of stereoscopic disparity, permitting vertical separation to be visually represented as differences in disparity...handling information via different sources (e.g., radar screen with a series of automated visual cues, paper or electronic flight progress strips, radio

  3. Managing Information Technology: Facing the Issues. Track VII: Applications and Technology Issues.

    ERIC Educational Resources Information Center

    CAUSE, Boulder, CO.

    Eight papers making up Track VII of the 1989 conference of the Professional Association for the Management of Information Technology in Higher Education (known as CAUSE, an acronym of the association's former name) are presented in this document. The focus of Track VII is on applications and technology issues, and the papers include: "The…

  4. Stereoscopic construction and practice of optoelectronic technology textbook

    NASA Astrophysics Data System (ADS)

    Zhou, Zigang; Zhang, Jinlong; Wang, Huili; Yang, Yongjia; Han, Yanling

    2017-08-01

    It is a professional degree course textbook for the Nation-class Specialty—Optoelectronic Information Science and Engineering, and it is also an engineering practice textbook for the cultivation of photoelectric excellent engineers. The book seeks to comprehensively introduce the theoretical and applied basis of optoelectronic technology, and it's closely linked to the current development of optoelectronic industry frontier and made up of following core contents, including the laser source, the light's transmission, modulation, detection, imaging and display. At the same time, it also embodies the features of the source of laser, the transmission of the waveguide, the electronic means and the optical processing methods.

  5. Prophylaxis in congenital factor VII deficiency: indications, efficacy and safety. Results from the Seven Treatment Evaluation Registry (STER).

    PubMed

    Napolitano, Mariasanta; Giansily-Blaizot, Muriel; Dolce, Alberto; Schved, Jean F; Auerswald, Guenter; Ingerslev, Jørgen; Bjerre, Jens; Altisent, Carmen; Charoenkwan, Pimlak; Michaels, Lisa; Chuansumrit, Ampaiwan; Di Minno, Giovanni; Caliskan, Umran; Mariani, Guglielmo

    2013-04-01

    Because of the very short half-life of factor VII, prophylaxis in factor VII deficiency is considered a difficult endeavor. The clinical efficacy and safety of prophylactic regimens, and indications for their use, were evaluated in factor VII-deficient patients in the Seven Treatment Evaluation Registry. Prophylaxis data (38 courses) were analyzed from 34 patients with severe factor VII deficiency (<1-45 years of age, 21 female). Severest phenotypes (central nervous system, gastrointestinal, joint bleeding episodes) were highly prevalent. Twenty-one patients received recombinant activated factor VII (24 courses), four received plasma-derived factor VII, and ten received fresh frozen plasma. Prophylactic schedules clustered into "frequent" courses (three times weekly, n=23) and "infrequent" courses (≤ 2 times weekly, n=15). Excluding courses for menorrhagia, "frequent" and "infrequent" courses produced 18/23 (78%) and 5/12 (41%) "excellent" outcomes, respectively; relative risk, 1.88; 95% confidence interval, 0.93-3.79; P=0.079. Long term prophylaxis lasted from 1 to >10 years. No thrombosis or new inhibitors occurred. In conclusion, a subset of patients with factor VII deficiency needed prophylaxis because of severe bleeding. Recombinant activated factor VII schedules based on "frequent" administrations (three times weekly) and a 90 μg/kg total weekly dose were effective. These data provide a rationale for long-term, safe prophylaxis in factor VII deficiency.

  6. A versatile stereoscopic visual display system for vestibular and oculomotor research.

    PubMed

    Kramer, P D; Roberts, D C; Shelhamer, M; Zee, D S

    1998-01-01

    Testing of the vestibular system requires a vestibular stimulus (motion) and/or a visual stimulus. We have developed a versatile, low cost, stereoscopic visual display system, using "virtual reality" (VR) technology. The display system can produce images for each eye that correspond to targets at any virtual distance relative to the subject, and so require the appropriate ocular vergence. We elicited smooth pursuit, "stare" optokinetic nystagmus (OKN) and after-nystagmus (OKAN), vergence for targets at various distances, and short-term adaptation of the vestibulo-ocular reflex (VOR), using both conventional methods and the stereoscopic display. Pursuit, OKN, and OKAN were comparable with both methods. When used with a vestibular stimulus, VR induced appropriate adaptive changes of the phase and gain of the angular VOR. In addition, using the VR display system and a human linear acceleration sled, we adapted the phase of the linear VOR. The VR-based stimulus system not only offers an alternative to more cumbersome means of stimulating the visual system in vestibular experiments, it also can produce visual stimuli that would otherwise be impractical or impossible. Our techniques provide images without the latencies encountered in most VR systems. Its inherent versatility allows it to be useful in several different types of experiments, and because it is software driven it can be quickly adapted to provide a new stimulus. These two factors allow VR to provide considerable savings in time and money, as well as flexibility in developing experimental paradigms.

  7. Cognitive responses and cortical oscillatory processing at various stereoscopic depths - a simultaneous EEG/MEG study.

    PubMed

    Cho, Hohyun; Kang, Min-Koo; Ahn, Sangtae; Kwon, Moonyoung; Yoon, Kuk-Jin; Kim, Kiwoong; Jun, Sung Chan

    2017-01-01

    Due to the recent explosion in various forms of 3D content, the evaluation of such content from a neuroscience perspective is quite interesting. However, existing investigations of cortical oscillatory responses in stereoscopic depth perception are quite rare. Therefore, we investigated spatiotemporal and spatio-temporo-spectral features at four different stereoscopic depths within the comfort zone. We adopted a simultaneous EEG/MEG acquisition technique to collect the oscillatory responses of eight participants. We defined subject-specific retinal disparities and designed a single trial-based stereoscopic viewing experimental paradigm. In the group analysis, we observed that, as the depth increased from Level 1 to Level 3, there was a time-locked increase in the N200 component in MEG and the P300 component in EEG in the occipital and parietal areas, respectively. In addition, initial alpha and beta event-related desynchronizations (ERD) were observed at approximately 500 to 1000 msec, while theta, alpha, and beta event-related synchronizations (ERS) appeared at approximately 1000 to 2000 ms. Interestingly, there was a saturation point in the increase in cognitive responses, including N200, P300, and alpha ERD, even when the depth increased only within the comfort zone. Meanwhile, the magnitude of low beta ERD decreased in the dorsal pathway as depth increased. From these findings, we concluded that cognitive responses are likely to become saturated in the visual comfort zone, while perceptual load may increase with depth.

  8. 76 FR 52656 - Lock+Hydro Friends Fund VII; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-23

    ... Friends Fund VII; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On August 4, 2011, Lock+Hydro Friends Fund VII, filed an... Friends Fund VII, 5090 Richmond Avenue 390, Houston, TX 77056; phone (877) 556- 6566 x709. FERC Contact...

  9. Differences in Optical Coherence Tomography Assessment of Bruch Membrane Opening Compared to Stereoscopic Photography for Estimating Cup-to-Disc Ratio.

    PubMed

    Mwanza, Jean-Claude; Huang, Linda Y; Budenz, Donald L; Shi, Wei; Huang, Gintien; Lee, Richard K

    2017-12-01

    To compare the vertical and horizontal cup-to-disc ratio (VCDR, HCDR) by an updated optical coherence tomography (OCT) Bruch membrane opening (BMO) algorithm and stereoscopic optic disc photograph readings by glaucoma specialists. Reliability analysis. A total of 195 eyes (116 glaucoma and 79 glaucoma suspect) of 99 patients with stereoscopic photographs and OCT scans of the optic discs taken during the same visit were compared. Optic disc photographs were read by 2 masked glaucoma specialists for VCDR and HCDR estimation. Intraclass correlation coefficient (ICC) and Bland-Altman plots were used to assess the agreement between photograph reading and OCT in estimating CDR. OCT images computed significantly larger VCDR and HCDR than photograph reading before and after stratifying eyes based on disc size (P < .001). The difference in CDR estimates between the 2 methods was equal to or greater than 0.2 in 29% and 35% of the eyes for VCDR and HCDR, respectively, with a mean difference of 0.3 in each case. The ICCs between the readers and OCT ranged between 0.50 and 0.63. The size of disagreement in VCDR correlated weakly with cup area in eyes with medium (r 2  = 0.10, P = .008) and large (r 2  = 0.09, P = .007) discs. OCT and photograph reading by clinicians agree poorly in CDR assessment. The difference in VCDR between the 2 methods was depended on cup area in medium and large discs. These differences should be considered when making conclusions regarding CDRs in clinical practice. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Discussion on Height Systems in Stereoscopic Mapping Using the ZY-3 Satellite Images

    NASA Astrophysics Data System (ADS)

    Zhao, L.; Fu, X.; Zhu, G.; Zhang, J.; Han, C.; Cheng, L.

    2018-04-01

    The ZY-3 is the civil high-resolution optical stereoscopic mapping satellite independently developed by China. It is mainly used for 1 : 50,000 scale topographic mapping. One of the distinguishing features of the ZY-3 is that the panchromatic triplet camera can obtain thousands of kilometers of continuous strip stereo data. The working mode is suitable for wide-range stereoscopic mapping, in particular global DEM extraction. The ZY-3 constellation is operated in a sun-synchronous at an altitude 505 km, with a 10:30 AM equator crossing time and a 29-day revisiting period. The panchromatic triplet sensors have excellent base-to-height ratio, which is advantageous for obtaining good mapping accuracy. In this paper the China quasi-geoid, EGM2008 and the height conversion method are discussed. It is pointed out that according to the current surveying and mapping specifications, almost all maps and charts use mean sea level for elevation. Experiments on bundle adjustment and DEM extraction with different height systems have been carried out in Liaoning Province of China. The results show that the similar accuracy can be obtained using different elevation system. According to the principle of geodesy and photogrammetry, it is recommended to use ellipsoidal height for satellite photogrammetric calculation and use the orthometric height in mapping production.

  11. Figure and Ground in the Visual Cortex: V2 Combines Stereoscopic Cues with Gestalt Rules

    PubMed Central

    Qiu, Fangtu T.; von der Heydt, Rüdiger

    2006-01-01

    Figure-ground organization is a process by which the visual system identifies some image regions as foreground and others as background, inferring three-dimensional (3D) layout from 2D displays. A recent study reported that edge responses of neurons in area V2 are selective for side-of-figure, suggesting that figure-ground organization is encoded in the contour signals (border-ownership coding). Here we show that area V2 combines two strategies of computation, one that exploits binocular stereoscopic information for the definition of local depth order, and another that exploits the global configuration of contours (gestalt factors). These are combined in single neurons so that the ‘near’ side of the preferred 3D edge generally coincides with the preferred side-of-figure in 2D displays. Thus, area V2 represents the borders of 2D figures as edges of surfaces, as if the figures were objects in 3D space. Even in 3D displays gestalt factors influence the responses and can enhance or null the stereoscopic depth information. PMID:15996555

  12. Employing WebGL to develop interactive stereoscopic 3D content for use in biomedical visualization

    NASA Astrophysics Data System (ADS)

    Johnston, Semay; Renambot, Luc; Sauter, Daniel

    2013-03-01

    Web Graphics Library (WebGL), the forthcoming web standard for rendering native 3D graphics in a browser, represents an important addition to the biomedical visualization toolset. It is projected to become a mainstream method of delivering 3D online content due to shrinking support for third-party plug-ins. Additionally, it provides a virtual reality (VR) experience to web users accommodated by the growing availability of stereoscopic displays (3D TV, desktop, and mobile). WebGL's value in biomedical visualization has been demonstrated by applications for interactive anatomical models, chemical and molecular visualization, and web-based volume rendering. However, a lack of instructional literature specific to the field prevents many from utilizing this technology. This project defines a WebGL design methodology for a target audience of biomedical artists with a basic understanding of web languages and 3D graphics. The methodology was informed by the development of an interactive web application depicting the anatomy and various pathologies of the human eye. The application supports several modes of stereoscopic displays for a better understanding of 3D anatomical structures.

  13. Figure and ground in the visual cortex: v2 combines stereoscopic cues with gestalt rules.

    PubMed

    Qiu, Fangtu T; von der Heydt, Rüdiger

    2005-07-07

    Figure-ground organization is a process by which the visual system identifies some image regions as foreground and others as background, inferring 3D layout from 2D displays. A recent study reported that edge responses of neurons in area V2 are selective for side-of-figure, suggesting that figure-ground organization is encoded in the contour signals (border ownership coding). Here, we show that area V2 combines two strategies of computation, one that exploits binocular stereoscopic information for the definition of local depth order, and another that exploits the global configuration of contours (Gestalt factors). These are combined in single neurons so that the "near" side of the preferred 3D edge generally coincides with the preferred side-of-figure in 2D displays. Thus, area V2 represents the borders of 2D figures as edges of surfaces, as if the figures were objects in 3D space. Even in 3D displays, Gestalt factors influence the responses and can enhance or null the stereoscopic depth information.

  14. Underuse of Title VII Funding for Indian Education in Arizona, Nevada, and Utah

    ERIC Educational Resources Information Center

    West Comprehensive Center at WestEd, 2015

    2015-01-01

    Title VII provides funding for the education of American Indian/Alaska Native students based on a formula grant available to school districts, charter schools, and local education agencies (LEAs). This report explores why some eligible schools and districts do not apply for federal Title VII, potentially resulting in American Indian/Alaska Native…

  15. Toward virtual anatomy: a stereoscopic 3-D interactive multimedia computer program for cranial osteology.

    PubMed

    Trelease, R B

    1996-01-01

    Advances in computer visualization and user interface technologies have enabled development of "virtual reality" programs that allow users to perceive and to interact with objects in artificial three-dimensional environments. Such technologies were used to create an image database and program for studying the human skull, a specimen that has become increasingly expensive and scarce. Stereoscopic image pairs of a museum-quality skull were digitized from multiple views. For each view, the stereo pairs were interlaced into a single, field-sequential stereoscopic picture using an image processing program. The resulting interlaced image files are organized in an interactive multimedia program. At run-time, gray-scale 3-D images are displayed on a large-screen computer monitor and observed through liquid-crystal shutter goggles. Users can then control the program and change views with a mouse and cursor to point-and-click on screen-level control words ("buttons"). For each view of the skull, an ID control button can be used to overlay pointers and captions for important structures. Pointing and clicking on "hidden buttons" overlying certain structures triggers digitized audio spoken word descriptions or mini lectures.

  16. Stereoscopic Feature Tracking System for Retrieving Velocity of Surface Waters

    NASA Astrophysics Data System (ADS)

    Zuniga Zamalloa, C. C.; Landry, B. J.

    2017-12-01

    The present work is concerned with the surface velocity retrieval of flows using a stereoscopic setup and finding the correspondence in the images via feature tracking (FT). The feature tracking provides a key benefit of substantially reducing the level of user input. In contrast to other commonly used methods (e.g., normalized cross-correlation), FT does not require the user to prescribe interrogation window sizes and removes the need for masking when specularities are present. The results of the current FT methodology are comparable to those obtained via Large Scale Particle Image Velocimetry while requiring little to no user input which allowed for rapid, automated processing of imagery.

  17. Looking White and Middle-Class: Stereoscopic Imagery and Technology in the Early Twentieth-Century United States

    ERIC Educational Resources Information Center

    Malin, Brenton J.

    2007-01-01

    This essay explores a series of discourses surrounding the images of the early twentieth-century stereoscope, focusing on Underwood & Underwood of Ottawa, Kansas, and the Keystone View Company, of Meadville, Pennsylvania. By publishing images of particular geographic areas and historical events, as well as compendium volumes that included…

  18. Leveraging Information Technology. Track VII: Outstanding Applications.

    ERIC Educational Resources Information Center

    CAUSE, Boulder, CO.

    Eight papers from the 1987 CAUSE conference's Track VII, Outstanding Applications, are presented. They include: "Image Databases in the University" (Reid Kaplan and Gordon Mathieson); "Using Information Technology for Travel Management at the University of Michigan" (Robert E. Russell and John C. Hufziger); "On-Line Access…

  19. The Effect of Neonatal Gene Therapy on Skeletal Manifestations in Mucopolysaccharidosis VII Dogs after a Decade

    PubMed Central

    Xing, Elizabeth M.; Knox, Van W.; O'Donnell, Patricia A.; Sikura, Tracey; Liu, Yuli; Wu, Susan; Casal, Margret L.; Haskins, Mark E.; Ponder, Katherine P.

    2013-01-01

    Mucopolysaccharidosis (MPS) VII is a lysosomal storage disease due to deficient activity of β-glucuronidase (GUSB), and results in glycosaminoglycan accumulation. Skeletal manifestations include bone dysplasia, degenerative joint disease, and growth retardation. One gene therapy approach for MPS VII involves neonatal intravenous injection of a gamma retroviral vector expressing GUSB, which results in stable expression in liver and secretion of enzyme into blood at levels predicted to be similar or higher to enzyme replacement therapy. The goal of this study was to evaluate the long-term effect of neonatal gene therapy on skeletal manifestations in MPS VII dogs. Treated MPS VII dogs could walk throughout their lives, while untreated MPS VII dogs could not stand beyond 6 months and were dead by 2 years. Luxation of the coxofemoral joint and the patella, dysplasia of the acetabulum and supracondylar ridge, deep erosions of the distal femur, and synovial hyperplasia were reduced, and the quality of articular bone was improved in treated dogs at 6 to 11 years of age compared with untreated MPS VII dogs at 2 years or less. However, treated dogs continued to have osteophyte formation, cartilage abnormalities, and an abnormal gait. Enzyme activity was found near synovial blood vessels, and there was 2% as much GUSB activity in synovial fluid as in serum. We conclude that neonatal gene therapy reduces skeletal abnormalities in MPS VII dogs, but clinically-relevant abnormalities remain. Enzyme replacement therapy will probably have similar limitations long-term. PMID:23628461

  20. PREFACE: VII Mexican School on Gravitation and Mathematical Physics

    NASA Astrophysics Data System (ADS)

    Alcubierre Moya, Miguel; García Compeán, Héctor Hugo; Ureña López, Luis Arturo

    2007-07-01

    The present collection of papers was presented during the VII Mexican School on Gravitation and Mathematical Physics, which was held in Playa del Carmen, Quintana Roo, México, from 26 November to 2 December 2006. The Mexican School on Gravitation and Mathematical Physics, sponsored by the Mexican Physical Society, started in 1994 with the purpose of discussing and exchanging current ideas in gravitational physics. Each school has been devoted to a particular subject, and on previous occasions these subjects have covered topics such as supergravity, branes, black holes, the early Universe, observational cosmology, and quantum gravity. At the dawn of the XXI Century, General Relativity has finally become a standard tool in our understanding of numerous astrophysical phenomena. At the same time, the new generation of large interferometric gravitational wave detectors that are just beginning operation holds the promise of finally allowing the detection of gravitational waves and opening a new window on the Universe. However, because of the complexity of the Einstein field equations, the modelling of realistic astrophysical systems and gravitational wave sources can only be done using numerical simulations. Because of this, we have dedicated our VII School to the topic of relativistic astrophysics and numerical relativity. As in all our previous Schools, international leaders in the field were invited to give courses and plenary lectures. The school was complemented with more specialized talks presented in parallel sessions, some of which are included in these proceedings. All the contributions in this volume have been refereed, and they represent a sample of the courses, invited talks and contributed talks presented during our VII School. Our deep gratitude goes to all those who contributed to these proceedings, and to making our VII Mexican School a great success. Miguel Alcubierre Moya, Héctor Hugo García Compeán and Luis Arturo Ureña López Editors

  1. 29 CFR 1604.8 - Relationship of title VII to the Equal Pay Act.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Relationship of title VII to the Equal Pay Act. 1604.8 Section 1604.8 Labor Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION GUIDELINES ON DISCRIMINATION BECAUSE OF SEX § 1604.8 Relationship of title VII to the Equal Pay Act. (a) The...

  2. 29 CFR 1604.8 - Relationship of title VII to the Equal Pay Act.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 4 2012-07-01 2012-07-01 false Relationship of title VII to the Equal Pay Act. 1604.8 Section 1604.8 Labor Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION GUIDELINES ON DISCRIMINATION BECAUSE OF SEX § 1604.8 Relationship of title VII to the Equal Pay Act. (a) The...

  3. 29 CFR 1604.8 - Relationship of title VII to the Equal Pay Act.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 4 2013-07-01 2013-07-01 false Relationship of title VII to the Equal Pay Act. 1604.8 Section 1604.8 Labor Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION GUIDELINES ON DISCRIMINATION BECAUSE OF SEX § 1604.8 Relationship of title VII to the Equal Pay Act. (a) The...

  4. 29 CFR 1604.8 - Relationship of title VII to the Equal Pay Act.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 4 2011-07-01 2011-07-01 false Relationship of title VII to the Equal Pay Act. 1604.8 Section 1604.8 Labor Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION GUIDELINES ON DISCRIMINATION BECAUSE OF SEX § 1604.8 Relationship of title VII to the Equal Pay Act. (a) The...

  5. Weather applications and products enabled through vehicle infrastructure integration (VII) : feasibility and concept development study

    DOT National Transportation Integrated Search

    2007-01-01

    Vehicle Infrastructure Integration (VII) involves the two-way wireless transmission of data from vehicle-to-vehicle and vehicle-to-infrastructure utilizing Dedicated Short Range Communications (DSRC). VII will enable the development of weather-relate...

  6. The Fokker "Trimotor F VII" commercial transport monoplane

    NASA Technical Reports Server (NTRS)

    1928-01-01

    Directly developed from the single engined type F VII ten passenger monoplanes, The Fokker Trimotor closely follows the commercial aircraft that preceded it. It has three Wright Whirlwind air-cooled engines, rated at 200 HP each.

  7. Treatment of lysosomal storage disease in MPS VII mice using a recombinant adeno-associated virus.

    PubMed

    Watson, G L; Sayles, J N; Chen, C; Elliger, S S; Elliger, C A; Raju, N R; Kurtzman, G J; Podsakoff, G M

    1998-12-01

    Mucopolysaccharidosis type VII (MPS VII) is a lysosomal storage disease caused by a genetic deficiency of beta-glucuronidase (GUS). We used a recombinant adeno-associated virus vector (AAV-GUS) to deliver GUS cDNA to MPS VII mice. The route of vector administration had a dramatic effect on the extent and distribution of GUS activity. Intramuscular injection of AAV-GUS resulted in high, localized production of GUS, while intravenous administration produced low GUS activity in several tissues. This latter treatment of MPS VII mice reduced glycosaminoglycan levels in the liver to normal and reduced storage granules dramatically. We show that a single administration of AAV-GUS can provide sustained expression of GUS in a variety of cell types and is sufficient to reverse the disease phenotype at least in the liver.

  8. Study of high-definition and stereoscopic head-aimed vision for improved teleoperation of an unmanned ground vehicle

    NASA Astrophysics Data System (ADS)

    Tyczka, Dale R.; Wright, Robert; Janiszewski, Brian; Chatten, Martha Jane; Bowen, Thomas A.; Skibba, Brian

    2012-06-01

    Nearly all explosive ordnance disposal robots in use today employ monoscopic standard-definition video cameras to relay live imagery from the robot to the operator. With this approach, operators must rely on shadows and other monoscopic depth cues in order to judge distances and object depths. Alternatively, they can contact an object with the robot's manipulator to determine its position, but that approach carries with it the risk of detonation from unintentionally disturbing the target or nearby objects. We recently completed a study in which high-definition (HD) and stereoscopic video cameras were used in addition to conventional standard-definition (SD) cameras in order to determine if higher resolutions and/or stereoscopic depth cues improve operators' overall performance of various unmanned ground vehicle (UGV) tasks. We also studied the effect that the different vision modes had on operator comfort. A total of six different head-aimed vision modes were used including normal-separation HD stereo, SD stereo, "micro" (reduced separation) SD stereo, HD mono, and SD mono (two types). In general, the study results support the expectation that higher resolution and stereoscopic vision aid UGV teleoperation, but the degree of improvement was found to depend on the specific task being performed; certain tasks derived notably more benefit from improved depth perception than others. This effort was sponsored by the Joint Ground Robotics Enterprise under Robotics Technology Consortium Agreement #69-200902 T01. Technical management was provided by the U.S. Air Force Research Laboratory's Robotics Research and Development Group at Tyndall AFB, Florida.

  9. Comparison between infrared optical and stereoscopic X-ray technologies for patient setup in image guided stereotactic radiotherapy.

    PubMed

    Tagaste, Barbara; Riboldi, Marco; Spadea, Maria F; Bellante, Simone; Baroni, Guido; Cambria, Raffaella; Garibaldi, Cristina; Ciocca, Mario; Catalano, Gianpiero; Alterio, Daniela; Orecchia, Roberto

    2012-04-01

    To compare infrared (IR) optical vs. stereoscopic X-ray technologies for patient setup in image-guided stereotactic radiotherapy. Retrospective data analysis of 233 fractions in 127 patients treated with hypofractionated stereotactic radiotherapy was performed. Patient setup at the linear accelerator was carried out by means of combined IR optical localization and stereoscopic X-ray image fusion in 6 degrees of freedom (6D). Data were analyzed to evaluate the geometric and dosimetric discrepancy between the two patient setup strategies. Differences between IR optical localization and 6D X-ray image fusion parameters were on average within the expected localization accuracy, as limited by CT image resolution (3 mm). A disagreement between the two systems below 1 mm in all directions was measured in patients treated for cranial tumors. In extracranial sites, larger discrepancies and higher variability were observed as a function of the initial patient alignment. The compensation of IR-detected rotational errors resulted in a significantly improved agreement with 6D X-ray image fusion. On the basis of the bony anatomy registrations, the measured differences were found not to be sensitive to patient breathing. The related dosimetric analysis showed that IR-based patient setup caused limited variations in three cases, with 7% maximum dose reduction in the clinical target volume and no dose increase in organs at risk. In conclusion, patient setup driven by IR external surrogates localization in 6D featured comparable accuracy with respect to procedures based on stereoscopic X-ray imaging. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Stereoscopic camera and viewing systems with undistorted depth presentation and reduced or eliminated erroneous acceleration and deceleration perceptions, or with perceptions produced or enhanced for special effects

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B. (Inventor)

    1991-01-01

    Methods for providing stereoscopic image presentation and stereoscopic configurations using stereoscopic viewing systems having converged or parallel cameras may be set up to reduce or eliminate erroneously perceived accelerations and decelerations by proper selection of parameters, such as an image magnification factor, q, and intercamera distance, 2w. For converged cameras, q is selected to be equal to Ve - qwl = 0, where V is the camera distance, e is half the interocular distance of an observer, w is half the intercamera distance, and l is the actual distance from the first nodal point of each camera to the convergence point, and for parallel cameras, q is selected to be equal to e/w. While converged cameras cannot be set up to provide fully undistorted three-dimensional views, they can be set up to provide a linear relationship between real and apparent depth and thus minimize erroneously perceived accelerations and decelerations for three sagittal planes, x = -w, x = 0, and x = +w which are indicated to the observer. Parallel cameras can be set up to provide fully undistorted three-dimensional views by controlling the location of the observer and by magnification and shifting of left and right images. In addition, the teachings of this disclosure can be used to provide methods of stereoscopic image presentation and stereoscopic camera configurations to produce a nonlinear relation between perceived and real depth, and erroneously produce or enhance perceived accelerations and decelerations in order to provide special effects for entertainment, training, or educational purposes.

  11. Distance Perception of Stereoscopically Presented Virtual Objects Optically Superimposed on Physical Objects by a Head-Mounted See-Through Display

    NASA Technical Reports Server (NTRS)

    Ellis, Stephen R.; Bucher, Urs J.; Statler, Irving C. (Technical Monitor)

    1994-01-01

    The influence of physically presented background stimuli on the perceived depth of optically overlaid, stereoscopic virtual images has been studied using headmounted stereoscopic, virtual image displays. These displays allow presentation of physically unrealizable stimulus combinations. Positioning of an opaque physical object either at the initial perceived depth of the virtual image or at a position substantially in front of the virtual image, causes the virtual image to perceptually move closer to the observer. In the case of objects positioned substantially in front of the virtual image, subjects often perceive the opaque object to become transparent. Evidence is presented that the apparent change of position caused by interposition of the physical object is not due to occlusion cues. According, it may have an alternative cause such as variation in the binocular vengeance position of the eyes caused by introduction of the physical object. This effect may complicate design of overlaid virtual image displays for near objects and appears to be related to the relative conspicuousness of the overlaid virtual image and the background. Consequently, it may be related to earlier analyses of John Foley which modeled open-loop pointing errors to stereoscopically presented points of light in terms of errors in determination of a reference point for interpretation of observed retinal disparities. Implications for the design of see-through displays for manufacturing will be discussed.

  12. The ice VII-ice X phase transition with implications for planetary interiors

    NASA Astrophysics Data System (ADS)

    Aarestad, B.; Frank, M. R.; Scott, H.; Bricker, M.; Prakapenka, V.

    2008-12-01

    A significant amount of research on the high pressure polymorphs of H2O have detailed the lattice structure and density of these phases, namely ice VI, ice VII, and ice X. These high pressure ices are noteworthy as they may comprise a considerable part of the interior of large icy planets and satellites. However, there is a dearth of data on how the incorporation of an impurity, charged or non-charged, affects the ice VII-ice X transition. This study examined the ice VII-ice X transition that occurs at approximately 62 GPa with a pure system and two select impure systems. Solutions of pure H2O, 1.6 mole percent NaCl in H2O, and 1.60 mole percent CH3OH in H2O were compressed in a diamond anvil cell (DAC). The experiments were performed at the GSECARS 13-BM-D beam line at the Advanced Photon Source at Argonne National Laboratory. Powder diffraction data of the ice samples were collected using monochromatic X-ray radiation, 0.2755 Å, and a MAR 345 online imaging system at intervals of approximately 2 GPa up to ~71.5, ~74.5, and ~68 GPa, respectively. Analyses of the data provided volume-pressure relations (at 298 K) which were used to detail the ice VII-ice X phase transition. The pressure of the phase transition, based upon an interpretation of the X-ray diffraction data, was found to vary as a function of the impurity type. Thus, the depth of the ice VII-ice X phase transition within an ice-rich planetary body can be influenced by trace-level impurities.

  13. Pseudane-VII Isolated from Pseudoalteromonas sp. M2 Ameliorates LPS-Induced Inflammatory Response In Vitro and In Vivo

    PubMed Central

    Kim, Mi Eun; Jung, Inae; Na, Ju Yong; Kim, Woo Jung; Kim, Young-Ok; Park, Yong-Duk; Lee, Jun Sik

    2017-01-01

    The ocean is a rich resource of flora, fauna, food, and biological products. We found a wild-type bacterial strain, Pseudoalteromonas sp. M2, from marine water and isolated various secondary metabolites. Pseudane-VII is a compound isolated from the Pseudoalteromonas sp. M2 metabolite that possesses anti-melanogenic activity. Inflammation is a response of the innate immune system to microbial infections. Macrophages have a critical role in fighting microbial infections and inflammation. Recent studies reported that various compounds derived from natural products can regulate immune responses including inflammation. However, the anti-inflammatory effects and mechanism of pseudane-VII in macrophages are still unknown. In this study, we investigated the anti-inflammatory effects of pseudane-VII. In present study, lipopolysaccharide (LPS)-induced nitric oxide (NO) production was significantly decreased by pseudane-VII treatment at 6 μM. Moreover, pseudane-VII treatment dose-dependently reduced mRNA levels of pro-inflammatory cytokines including inos, cox-2, il-1β, tnf-α, and il-6 in LPS-stimulated macrophages. Pseudane-VII also diminished iNOS protein levels and IL-1β secretion. In addition, Pseudane-VII elicited anti-inflammatory effects by inhibiting ERK, JNK, p38, and nuclear factor (NF)-κB-p65 phosphorylation. Consistently, pseudane-VII was also shown to inhibit the LPS-stimulated release of IL-1β and expression of iNOS in mice. These results suggest that pseudane-VII exerted anti-inflammatory effects on LPS-stimulated macrophage activation via inhibition of ERK, JNK, p38 MAPK phosphorylation, and pro-inflammatory gene expression. These findings may provide new approaches in the effort to develop anti-inflammatory therapeutics. PMID:29104209

  14. Pseudane-VII Isolated from Pseudoalteromonas sp. M2 Ameliorates LPS-Induced Inflammatory Response In Vitro and In Vivo.

    PubMed

    Kim, Mi Eun; Jung, Inae; Lee, Jong Suk; Na, Ju Yong; Kim, Woo Jung; Kim, Young-Ok; Park, Yong-Duk; Lee, Jun Sik

    2017-11-01

    The ocean is a rich resource of flora, fauna, food, and biological products. We found a wild-type bacterial strain, Pseudoalteromonas sp. M2, from marine water and isolated various secondary metabolites. Pseudane-VII is a compound isolated from the Pseudoalteromonas sp. M2 metabolite that possesses anti-melanogenic activity. Inflammation is a response of the innate immune system to microbial infections. Macrophages have a critical role in fighting microbial infections and inflammation. Recent studies reported that various compounds derived from natural products can regulate immune responses including inflammation. However, the anti-inflammatory effects and mechanism of pseudane-VII in macrophages are still unknown. In this study, we investigated the anti-inflammatory effects of pseudane-VII. In present study, lipopolysaccharide (LPS)-induced nitric oxide (NO) production was significantly decreased by pseudane-VII treatment at 6 μM. Moreover, pseudane-VII treatment dose-dependently reduced mRNA levels of pro-inflammatory cytokines including inos , cox-2 , il-1β , tnf-α , and il-6 in LPS-stimulated macrophages. Pseudane-VII also diminished iNOS protein levels and IL-1β secretion. In addition, Pseudane-VII elicited anti-inflammatory effects by inhibiting ERK, JNK, p38, and nuclear factor (NF)-κB-p65 phosphorylation. Consistently, pseudane-VII was also shown to inhibit the LPS-stimulated release of IL-1β and expression of iNOS in mice. These results suggest that pseudane-VII exerted anti-inflammatory effects on LPS-stimulated macrophage activation via inhibition of ERK, JNK, p38 MAPK phosphorylation, and pro-inflammatory gene expression. These findings may provide new approaches in the effort to develop anti-inflammatory therapeutics.

  15. The effect of neonatal gene therapy on skeletal manifestations in mucopolysaccharidosis VII dogs after a decade.

    PubMed

    Xing, Elizabeth M; Knox, Van W; O'Donnell, Patricia A; Sikura, Tracey; Liu, Yuli; Wu, Susan; Casal, Margret L; Haskins, Mark E; Ponder, Katherine P

    2013-06-01

    Mucopolysaccharidosis (MPS) VII is a lysosomal storage disease due to deficient activity of β-glucuronidase (GUSB), and results in glycosaminoglycan accumulation. Skeletal manifestations include bone dysplasia, degenerative joint disease, and growth retardation. One gene therapy approach for MPS VII involves neonatal intravenous injection of a gamma retroviral vector expressing GUSB, which results in stable expression in liver and secretion of enzyme into blood at levels predicted to be similar or higher to enzyme replacement therapy. The goal of this study was to evaluate the long-term effect of neonatal gene therapy on skeletal manifestations in MPS VII dogs. Treated MPS VII dogs could walk throughout their lives, while untreated MPS VII dogs could not stand beyond 6 months and were dead by 2 years. Luxation of the coxofemoral joint and the patella, dysplasia of the acetabulum and supracondylar ridge, deep erosions of the distal femur, and synovial hyperplasia were reduced, and the quality of articular bone was improved in treated dogs at 6 to 11 years of age compared with untreated MPS VII dogs at 2 years or less. However, treated dogs continued to have osteophyte formation, cartilage abnormalities, and an abnormal gait. Enzyme activity was found near synovial blood vessels, and there was 2% as much GUSB activity in synovial fluid as in serum. We conclude that neonatal gene therapy reduces skeletal abnormalities in MPS VII dogs, but clinically-relevant abnormalities remain. Enzyme replacement therapy will probably have similar limitations long-term. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Radiographic evaluation of bones and joints in mucopolysaccharidosis I and VII dogs after neonatal gene therapy.

    PubMed

    Herati, Ramin Sedaghat; Knox, Van W; O'Donnell, Patricia; D'Angelo, Marina; Haskins, Mark E; Ponder, Katherine P

    2008-11-01

    Mucopolysaccharidosis I (MPS I) and MPS VII are due to deficient activity of the glycosaminoglycan-degrading lysosomal enzymes alpha-L-iduronidase and beta-glucuronidase, respectively, and result in abnormal bones and joints. Here, the severity of skeletal disease in MPS I and MPS VII dogs and the effects of neonatal gene therapy were evaluated. For untreated MPS VII dogs, the lengths of the second cervical vertebrae (C2) and the femur were only 56% and 84% of normal, respectively, and bone dysplasia and articular erosions, and joint subluxation were severe. Previously, we reported that neonatal intravenous injection of a retroviral vector (RV) with the appropriate gene resulted in expression in liver and blood cells, and high serum enzyme activity. In this study, we demonstrate that C2 and femurs of RV-treated MPS VII dogs were longer at 82% and 101% of normal, respectively, and there were partial improvements of qualitative abnormalities. For untreated MPS I dogs, the lengths of C2 and femurs (91% and 96% of normal, respectively) were not significantly different from normal dogs. Qualitative changes in MPS I bones and joints were generally modest and were partially improved with RV treatment, although cervical spine disease was severe and was difficult to correct with gene therapy in both models. The greater severity of skeletal disease in MPS VII than in MPS I dogs may reflect accumulation of chondroitin sulfate in cartilage in MPS VII, or could relate to the specific mutations. Neonatal RV-mediated gene therapy ameliorates, but does not prevent, skeletal disease in MPS I and MPS VII dogs.

  17. Factors Influencing Title VII Bilingual Program Institutionalization.

    ERIC Educational Resources Information Center

    Lewis, Gerald R.; And Others

    1985-01-01

    This study of the primary restraining and driving forces that influence Title VII bilingual education programs found the external environment, the local community, to be the main factor influencing institutionalization and self-renewal. The internal environment--the local school, and the local school's organization or central office, school board,…

  18. 76 FR 57013 - Recordkeeping and Reporting Requirements Under Title VII, the ADA, and GINA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-15

    ... EQUAL EMPLOYMENT OPPORTUNITY COMMISSION 29 CFR Part 1602 RIN 3046-AA89 Recordkeeping and Reporting Requirements Under Title VII, the ADA, and GINA AGENCY: Equal Employment Opportunity Commission. ACTION... under title VII, the ADA, and GINA. (76 FR 31892, June 2, 2011). No requests to present oral testimony...

  19. Organizational Learning Goes Virtual?: A Study of Employees' Learning Achievement in Stereoscopic 3D Virtual Reality

    ERIC Educational Resources Information Center

    Lau, Kung Wong

    2015-01-01

    Purpose: This study aims to deepen understanding of the use of stereoscopic 3D technology (stereo3D) in facilitating organizational learning. The emergence of advanced virtual technologies, in particular to the stereo3D virtual reality, has fundamentally changed the ways in which organizations train their employees. However, in academic or…

  20. Comparing Short- and Long-Term Learning Effects between Stereoscopic and Two-Dimensional Film at a Planetarium

    ERIC Educational Resources Information Center

    Price, C. Aaron; Lee, Hee-Sun; Subbarao, Mark; Kasal, Evan; Aguileara, Julieta

    2015-01-01

    Science centers such as museums and planetariums have used stereoscopic ("three-dimensional") films to draw interest from and educate their visitors for decades. Despite the fact that most adults who are finished with their formal education get their science knowledge from such free-choice learning settings very little is known about the…

  1. Three-Dimensional Stereoscopic Tracking Velocimetry and Experimental/Numerical Comparison of Directional Solidification

    NASA Technical Reports Server (NTRS)

    Lee, David; Ge, Yi; Cha, Soyoung Stephen; Ramachandran, Narayanan; Rose, M. Franklin (Technical Monitor)

    2001-01-01

    Measurement of three-dimensional (3-D) three-component velocity fields is of great importance in both ground and space experiments for understanding materials processing and fluid physics. The experiments in these fields most likely inhibit the application of conventional planar probes for observing 3-D phenomena. Here, we present the investigation results of stereoscopic tracking velocimetry (STV) for measuring 3-D velocity fields, which include diagnostic technology development, experimental velocity measurement, and comparison with analytical and numerical computation. STV is advantageous in system simplicity for building compact hardware and in software efficiency for continual near-real-time monitoring. It has great freedom in illuminating and observing volumetric fields from arbitrary directions. STV is based on stereoscopic observation of particles-Seeded in a flow by CCD sensors. In the approach, part of the individual particle images that provide data points is likely to be lost or cause errors when their images overlap and crisscross each other especially under a high particle density. In order to maximize the valid recovery of data points, neural networks are implemented for these two important processes. For the step of particle overlap decomposition, the back propagation neural network is utilized because of its ability in pattern recognition with pertinent particle image feature parameters. For the step of particle tracking, the Hopfield neural network is employed to find appropriate particle tracks based on global optimization. Our investigation indicates that the neural networks are very efficient and useful for stereoscopically tracking particles. As an initial assessment of the diagnostic technology performance, laminar water jets with and without pulsation are measured. The jet tip velocity profiles are in good agreement with analytical predictions. Finally, for testing in material processing applications, a simple directional solidification

  2. Stereoscopic Planar Laser-Induced Fluorescence Imaging at 500 kHz

    NASA Technical Reports Server (NTRS)

    Medford, Taylor L.; Danehy, Paul M.; Jones, Stephen B.; Jiang, N.; Webster, M.; Lempert, Walter; Miller, J.; Meyer, T.

    2011-01-01

    A new measurement technique for obtaining time- and spatially-resolved image sequences in hypersonic flows is developed. Nitric-oxide planar laser-induced fluorescence (NO PLIF) has previously been used to investigate transition from laminar to turbulent flow in hypersonic boundary layers using both planar and volumetric imaging capabilities. Low flow rates of NO were typically seeded into the flow, minimally perturbing the flow. The volumetric imaging was performed at a measurement rate of 10 Hz using a thick planar laser sheet that excited NO fluorescence. The fluorescence was captured by a pair of cameras having slightly different views of the flow. Subsequent stereoscopic reconstruction of these images allowed the three-dimensional flow structures to be viewed. In the current paper, this approach has been extended to 50,000 times higher repetition rates. A laser operating at 500 kHz excites the seeded NO molecules, and a camera, synchronized with the laser and fitted with a beam-splitting assembly, acquires two separate images of the flow. The resulting stereoscopic images provide three-dimensional flow visualizations at 500 kHz for the first time. The 200 ns exposure time in each frame is fast enough to freeze the flow while the 500 kHz repetition rate is fast enough to time-resolve changes in the flow being studied. This method is applied to visualize the evolving hypersonic flow structures that propagate downstream of a discrete protuberance attached to a flat plate. The technique was demonstrated in the NASA Langley Research Center s 31-Inch Mach 10 Air Tunnel facility. Different tunnel Reynolds number conditions, NO flow rates and two different cylindrical protuberance heights were investigated. The location of the onset of flow unsteadiness, an indicator of transition, was observed to move downstream during the tunnel runs, coinciding with an increase in the model temperature.

  3. 1990 Clean Air Act Amendment Summary: Title VII

    EPA Pesticide Factsheets

    This page provides an overview of the 1990 amendments to Title VII of the Clean Air Act, which were enacted to curb acid rain, urban air pollution and toxic air emissions. The edits to this title deal with enforcement provisions.

  4. Ice-VII inclusions in diamonds: Evidence for aqueous fluid in Earth’s deep mantle

    NASA Astrophysics Data System (ADS)

    Tschauner, O.; Huang, S.; Greenberg, E.; Prakapenka, V. B.; Ma, C.; Rossman, G. R.; Shen, A. H.; Zhang, D.; Newville, M.; Lanzirotti, A.; Tait, K.

    2018-03-01

    Water-rich regions in Earth’s deeper mantle are suspected to play a key role in the global water budget and the mobility of heat-generating elements. We show that ice-VII occurs as inclusions in natural diamond and serves as an indicator for such water-rich regions. Ice-VII, the residue of aqueous fluid present during growth of diamond, crystallizes upon ascent of the host diamonds but remains at pressures as high as 24 gigapascals; it is now recognized as a mineral by the International Mineralogical Association. In particular, ice-VII in diamonds points toward fluid-rich locations in the upper transition zone and around the 660-kilometer boundary.

  5. Lack of bleeding in patients with severe factor VII deficiency.

    PubMed

    Barnett, J Mark; Demel, Kurt C; Mega, Anthony E; Butera, James N; Sweeney, Joseph D

    2005-02-01

    Factor VII deficiency, although rare, is now recognized as the most common autosomal recessive inherited factor deficiency. It is usually considered to be associated with bleeding only in the severely affected subject and heterozygotes (>10%) are not considered at risk. The general recommendation for surgery is to achieve a FVII level in excess of 15% (0.15 1U/mL). We present three cases of severe factor VII deficiency, each of whom appeared hemostatically competent based on clinical history. Subject 1 is a 33 year-old African-American female with a baseline FVII of <1%, who had a fractured tibia requiring open reduction with internal fixation without any FVII replacement and subsequently underwent successful laparoscopic knee surgery with a factor VII level measured at 6%. Subject 2 is a 58 year-old African-American female with a factor VII level of 9% who underwent an elective left total hip replacement without any factor replacement and had no excessive bleeding, but who sustained a pulmonary embolism postoperatively. Subject 3 is a 19-year-old African-American male with a baseline FVII of 1% with a history of active participation in football without noticeable injury and who underwent an emergent appendectomy without bleeding. These three cases represent individuals with the severe form of FVII deficiency who did not exhibit excessive bleeding when challenged with surgical procedures. The clinical history would appear the most valuable tool in predicting the likelihood of bleeding in these patients, and we suggest that the presumption that all patients with severe FVII deficiency should receive replacement therapy before surgical procedures may not be valid in all cases. Copyright 2005 Wiley-Liss, Inc.

  6. 20 CFR Appendix Vii to Subpart C... - “Old-Law” Contribution and Benefit Base

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Appendix VII to Subpart C of Part 404 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND DISABILITY INSURANCE (1950- ) Computing Primary Insurance Amounts Pt. 404, Subpt. C, App. VII... Security Act without the enactment of the 1977 amendments. Year Amount 1979 $18,900 1980 20,400 1981 22,200...

  7. Contribution of tertiary amino groups to Re(VII) biosorption on modified corn stalk: competitiveness and regularity.

    PubMed

    Lou, Zhenning; Zhao, Ziyi; Li, Yexia; Shan, Weijun; Xiong, Ying; Fang, Dawei; Yue, Shuang; Zang, Shuliang

    2013-04-01

    The effects of basic strength and steric hindrance of gels modified by dimethylamine, diethylamine, di-n-octylamine and di-2-ethylhexylamine, respectively, on rhenium (Re(VII)) adsorption capacity and selectivity were discussed. By comparing with the adsorption of other coexisting metals, such as Mo(VI), Cu(II), Pb(II), Fe(III), Zn(II), Mn(VII) and Ni(II), the gel modified by di-n-octylamine (DNOA-OCS) showed a high affinity for Re(VII) at higher hydrochloric acid concentration (C(H)(+)≥1.0 mol L(-1)), and the maximum adsorption capacity was 98.69 mg g(-1). This article not only described the adsorption behavior but also suggested isotherms, kinetics and thermodynamics of Re(VII) onto the DNOA-OCS gel in an aqueous medium using several models. Further study on adsorption of rhenium in a fixed-bed column packed with the DNOA-OCS gel under continuous and recirculating modes could confirm that the corn stalk gel modified by di-n-octylamine could be used as the adsorbent of Re(VII) from Mo-containing wastewater. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Measuring X-ray anisotropy in solar flares. Prospective stereoscopic capabilities of STIX and MiSolFA

    NASA Astrophysics Data System (ADS)

    Casadei, Diego; Jeffrey, Natasha L. S.; Kontar, Eduard P.

    2017-09-01

    Context. During a solar flare, a large percentage of the magnetic energy released goes into the kinetic energy of non-thermal particles, with X-ray observations providing a direct connection to keV flare-accelerated electrons. However, the electron angular distribution, a prime diagnostic tool of the acceleration mechanism and transport, is poorly known. Aims: During the next solar maximum, two upcoming space-borne X-ray missions, STIX on board Solar Orbiter and MiSolFA, will perform stereoscopic X-ray observations of solar flares at two different locations: STIX at 0.28 AU (at perihelion) and up to inclinations of 25°, and MiSolFA in a low-Earth orbit. The combined observations from these cross-calibrated detectors will allow us to infer the electron anisotropy of individual flares confidently for the first time. Methods: We simulated both instrumental and physical effects for STIX and MiSolFA including thermal shielding, background and X-ray Compton backscattering (albedo effect) in the solar photosphere. We predict the expected number of observable flares available for stereoscopic measurements during the next solar maximum. We also discuss the range of useful spacecraft observation angles for the challenging case of close-to-isotropic flare anisotropy. Results: The simulated results show that STIX and MiSolFA will be capable of detecting low levels of flare anisotropy, for M1-class or stronger flares, even with a relatively small spacecraft angular separation of 20-30°. Both instruments will directly measure the flare X-ray anisotropy of about 40 M- and X-class solar flares during the next solar maximum. Conclusions: Near-future stereoscopic observations with Solar Orbiter/STIX and MiSolFA will help distinguishing between competing flare-acceleration mechanisms, and provide essential constraints regarding collisional and non-collisional transport processes occurring in the flaring atmosphere for individual solar flares.

  9. Disparity modifications and the emotional effects of stereoscopic images

    NASA Astrophysics Data System (ADS)

    Kawai, Takashi; Atsuta, Daiki; Tomiyama, Yuya; Kim, Sanghyun; Morikawa, Hiroyuki; Mitsuya, Reiko; Häkkinen, Jukka

    2014-03-01

    This paper describes a study that focuses on disparity changes in emotional scenes of stereoscopic (3D) images, in which an examination of the effects on pleasant and arousal was carried out by adding binocular disparity to 2D images that evoke specific emotions, and applying disparity modification based on the disparity analysis of famous 3D movies. From the results of the experiment, for pleasant, a significant difference was found only for the main effect of the emotions. On the other hand, for arousal, there was a trend of increasing the evaluation values in the order 2D condition, 3D condition and 3D condition applied the disparity modification for happiness, surprise, and fear. This suggests the possibility that binocular disparity and the modification affect arousal.

  10. Optical cross-talk and visual comfort of a stereoscopic display used in a real-time application

    NASA Astrophysics Data System (ADS)

    Pala, S.; Stevens, R.; Surman, P.

    2007-02-01

    Many 3D systems work by presenting to the observer stereoscopic pairs of images that are combined to give the impression of a 3D image. Discomfort experienced when viewing for extended periods may be due to several factors, including the presence of optical crosstalk between the stereo image channels. In this paper we use two video cameras and two LCD panels viewed via a Helmholtz arrangement of mirrors, to display a stereoscopic image inherently free of crosstalk. Simple depth discrimination tasks are performed whilst viewing the 3D image and controlled amounts of image crosstalk are introduced by electronically mixing the video signals. Error monitoring and skin conductance are used as measures of workload as well as traditional subjective questionnaires. We report qualitative measurements of user workload under a variety of viewing conditions. This pilot study revealed a decrease in task performance and increased workload as crosstalk was increased. The observations will assist in the design of further trials planned to be conducted in a medical environment.

  11. Extending the Life of Virtual Heritage: Reuse of Tls Point Clouds in Synthetic Stereoscopic Spherical Images

    NASA Astrophysics Data System (ADS)

    Garcia Fernandez, J.; Tammi, K.; Joutsiniemi, A.

    2017-02-01

    Recent advances in Terrestrial Laser Scanner (TLS), in terms of cost and flexibility, have consolidated this technology as an essential tool for the documentation and digitalization of Cultural Heritage. However, once the TLS data is used, it basically remains stored and left to waste.How can highly accurate and dense point clouds (of the built heritage) be processed for its reuse, especially to engage a broader audience? This paper aims to answer this question by a channel that minimizes the need for expert knowledge, while enhancing the interactivity with the as-built digital data: Virtual Heritage Dissemination through the production of VR content. Driven by the ProDigiOUs project's guidelines on data dissemination (EU funded), this paper advances in a production path to transform the point cloud into virtual stereoscopic spherical images, taking into account the different visual features that produce depth perception, and especially those prompting visual fatigue while experiencing the VR content. Finally, we present the results of the Hiedanranta's scans transformed into stereoscopic spherical animations.

  12. Radiographic Evaluation of Bones and Joints in Mucopolysaccharidosis I and VII Dogs After Neonatal Gene Therapy

    PubMed Central

    Herati, Ramin Sedaghat; Knox, Van W.; O’Donnell, Patricia; D’Angelo, Marina; Haskins, Mark E.; Ponder, Katherine P.

    2009-01-01

    Mucopolysaccharidosis I (MPS I) and MPS VII are due to deficient activity of the glycosaminoglycan-degrading lysosomal enzymes α-L-iduronidase and β-glucuronidase, respectively, and result in abnormal bones and joints. Here, the severity of skeletal disease in MPS I and MPS VII dogs and the effects of neonatal gene therapy were evaluated. For untreated MPS VII dogs, the lengths of the second cervical vertebrae (C2) and the femur were only 56% and 84% of normal, respectively, and bone dysplasia and articular erosions, and joint subluxation were severe. Previously, we reported that neonatal intravenous injection of a retroviral vector (RV) with the appropriate gene resulted in expression in liver and blood cells, and high serum enzyme activity. In this study, we demonstrate that C2 and femurs of RV-treated MPS VII dogs were longer at 82% and 101% of normal, respectively, and there were partial improvements of qualitative abnormalities. For untreated MPS I dogs, the lengths of C2 and femurs (91% and 96% of normal, respectively) were not significantly different from normal dogs. Qualitative changes in MPS I bones and joints were generally modest and were partially improved with RV treatment, although cervical spine disease was severe and was difficult to correct with gene therapy in both models. The greater severity of skeletal disease in MPS VII than in MPS I dogs may reflect accumulation of chondroitin sulfate in cartilage in MPS VII, or could relate to the specific mutations. Neonatal RV-mediated gene therapy ameliorates, but does not prevent, skeletal disease in MPS I and MPS VII dogs. PMID:18707908

  13. Anti-Type VII Collagen Antibodies Are Identified in a Subpopulation of Bullous Pemphigoid Patients With Relapse

    PubMed Central

    Giusti, Delphine; Gatouillat, Grégory; Le Jan, Sébastien; Plée, Julie; Bernard, Philippe; Antonicelli, Frank; Pham, Bach-Nga

    2018-01-01

    Bullous pemphigoid (BP) is an autoimmune bullous skin disease characterized by anti-BP180 and anti-BP230 autoantibodies (AAbs). Mucous membrane involvement is an uncommon clinical feature of BP which may evoke epidermolysis bullosa acquisita, another skin autoimmune disease characterized by anti-type VII collagen AAbs. We therefore evaluated the presence of anti-type VII collagen AAbs in the serum of BP patients with and without mucosal lesions at time of diagnosis and under therapy. Anti-BP180, anti-BP230, and anti-type VII collagen AAbs were measured by ELISA in the serum of unselected patients fulfilling clinical and histo/immunopathological BP criteria at baseline (n = 71) and at time of relapse (n = 24). At baseline, anti-type VII collagen AAbs were detected in 2 out of 24 patients with BP presenting with mucosal involvement, but not in patients without mucosal lesions (n = 47). At the time of relapse, 10 out of 24 BP patients either displayed a significant induction or increase of concentrations of anti-type VII collagen AAbs (P < 0.01), independently of mucosal involvement. Those 10 relapsing BP patients were also characterized by a sustained high concentration of anti-BP180 AAb, whereas the serum anti-BP230 AAb concentrations did not vary in BP patients with relapse according to the presence of anti-type VII collagen AAbs. Thus, our study showed that anti-type VII collagen along with anti-BP180 AAbs detection stratified BP patients at time of relapse, illustrating a still dysregulated immune response that could reflect a potential epitope spreading mechanism in those BP patients. PMID:29619029

  14. A presomite human embryo of Horizon VII.

    PubMed Central

    Rewell, R E; Harrison, R G

    1976-01-01

    A presomite embryo of Horizon VII aged approximately 18 days is described and illustrated. It is compared with some other embryos of a similar age, and a considerable variation of histological characteristics within the same Horizon is noted. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 PMID:1254532

  15. Employment Discrimination: Alternative Remedies to Title VII

    ERIC Educational Resources Information Center

    Whittier, Ann M.; Whittier, Gary L.

    1975-01-01

    This article is intended to familiarize Missouri lawyers with the advantages, limitations, and important procedural aspects of four remedies that can supplement or offer alternatives to Title VII litigation in appropriate situations: The Equal Pay Act; section 1983 of the Civil Rights Act of 1871, Executive Order No. 11,246, and the Missouri Fair…

  16. The Influence of Manifest Strabismus and Stereoscopic Vision on Non-Verbal Abilities of Visually Impaired Children

    ERIC Educational Resources Information Center

    Gligorovic, Milica; Vucinic, Vesna; Eskirovic, Branka; Jablan, Branka

    2011-01-01

    This research was conducted in order to examine the influence of manifest strabismus and stereoscopic vision on non-verbal abilities of visually impaired children aged between 7 and 15. The sample included 55 visually impaired children from the 1st to the 6th grade of elementary schools for visually impaired children in Belgrade. RANDOT stereotest…

  17. Ice-VII inclusions in diamonds: Evidence for aqueous fluid in Earth's deep mantle.

    PubMed

    Tschauner, O; Huang, S; Greenberg, E; Prakapenka, V B; Ma, C; Rossman, G R; Shen, A H; Zhang, D; Newville, M; Lanzirotti, A; Tait, K

    2018-03-09

    Water-rich regions in Earth's deeper mantle are suspected to play a key role in the global water budget and the mobility of heat-generating elements. We show that ice-VII occurs as inclusions in natural diamond and serves as an indicator for such water-rich regions. Ice-VII, the residue of aqueous fluid present during growth of diamond, crystallizes upon ascent of the host diamonds but remains at pressures as high as 24 gigapascals; it is now recognized as a mineral by the International Mineralogical Association. In particular, ice-VII in diamonds points toward fluid-rich locations in the upper transition zone and around the 660-kilometer boundary. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  18. Tissue factor is an angiogenic-specific receptor for factor VII-targeted immunotherapy and photodynamic therapy.

    PubMed

    Hu, Zhiwei; Cheng, Jijun; Xu, Jie; Ruf, Wolfram; Lockwood, Charles J

    2017-02-01

    Identification of target molecules specific for angiogenic vascular endothelial cells (VEC), the inner layer of pathological neovasculature, is critical for discovery and development of neovascular-targeting therapy for angiogenesis-dependent human diseases, notably cancer, macular degeneration and endometriosis, in which vascular endothelial growth factor (VEGF) plays a central pathophysiological role. Using VEGF-stimulated vascular endothelial cells (VECs) isolated from microvessels, venous and arterial blood vessels as in vitro angiogenic models and unstimulated VECs as a quiescent VEC model, we examined the expression of tissue factor (TF), a membrane-bound receptor on the angiogenic VEC models compared with quiescent VEC controls. We found that TF is specifically expressed on angiogenic VECs in a time-dependent manner in microvessels, venous and arterial vessels. TF-targeted therapeutic agents, including factor VII (fVII)-IgG1 Fc and fVII-conjugated photosensitizer, can selectively bind angiogenic VECs, but not the quiescent VECs. Moreover, fVII-targeted photodynamic therapy can selectively and completely eradicate angiogenic VECs. We conclude that TF is an angiogenic-specific receptor and the target molecule for fVII-targeted therapeutics. This study supports clinical trials of TF-targeted therapeutics for the treatment of angiogenesis-dependent diseases such as cancer, macular degeneration and endometriosis.

  19. Active site mutant transgene confers tolerance to human β-glucuronidase without affecting the phenotype of MPS VII mice

    PubMed Central

    Sly, William S.; Vogler, Carole; Grubb, Jeffrey H.; Zhou, Mi; Jiang, Jinxing; Zhou, Xiao Yan; Tomatsu, Shunji; Bi, Yanhua; Snella, Elizabeth M.

    2001-01-01

    Mucopolysaccharidosis type VII (MPS VII; Sly syndrome) is an autosomal recessive lysosomal storage disorder due to an inherited deficiency of β-glucuronidase. A naturally occurring mouse model for this disease was discovered at The Jackson Laboratory and shown to be due to homozygosity for a 1-bp deletion in exon 10 of the gus gene. The murine model MPS VII (gusmps/mps) has been very well characterized and used extensively to evaluate experimental strategies for lysosomal storage diseases, including bone marrow transplantation, enzyme replacement therapy, and gene therapy. To enhance the value of this model for enzyme and gene therapy, we produced a transgenic mouse expressing the human β-glucuronidase cDNA with an amino acid substitution at the active site nucleophile (E540A) and bred it onto the MPS VII (gusmps/mps) background. We demonstrate here that the mutant mice bearing the active site mutant human transgene retain the clinical, morphological, biochemical, and histopathological characteristics of the original MPS VII (gusmps/mps) mouse. However, they are now tolerant to immune challenge with human β-glucuronidase. This “tolerant MPS VII mouse model” should be useful for preclinical trials evaluating the effectiveness of enzyme and/or gene therapy with the human gene products likely to be administered to human patients with MPS VII. PMID:11226217

  20. Subjective Criteria in Employment Decisions Under Title VII

    ERIC Educational Resources Information Center

    Stacy, Donald R.

    1976-01-01

    Since higher echelon jobs have been drawn into litigation under Title VII, subjective criteria have been employed. The legal ramifications of assessing noncognitive traits such as leadership, aggressiveness, and attitude are discussed. Available from: the University of Georgia School of Law, Athens, Georgia 30602. (LBH)

  1. 20 CFR Appendix Vii to Subpart C... - “Old-Law” Contribution and Benefit Base

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 2 2013-04-01 2013-04-01 false âOld-Lawâ Contribution and Benefit Base VII... Appendix VII to Subpart C of Part 404—“Old-Law” Contribution and Benefit Base Explanation: We use these... appendix IV). This is the contribution and benefit base that would have been effective under the Social...

  2. Release of the ENDF/B-VII.1 Evaluated Nuclear Data File

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, David

    2012-06-30

    The Cross Section Evaluation Working Group (CSEWG) released the ENDF/B-VII.1 library on December 22, 2011. The ENDF/B-VII.1 library is CSEWG's latest recommended evaluated nuclear data file for use in nuclear science and technology applications, and incorporates advances made in the five years since the release of ENDF/B-VII.0, including: many new evaluation in the neutron sublibrary (423 in all and over 190 of these contain covariances), new fission product yields and a greatly improved decay data sublibrary. This summary barely touches on the five years worth of advances present in the ENDF/B-VII.1 library. We expect that these changes will lead tomore » improved integral performance in reactors and other applications. Furthermore, the expansion of covariance data in this release will allow for better uncertainty quantification, reducing design margins and costs. The ENDF library is an ongoing and evolving effort. Currently, the ENDF data community embarking on several parallel efforts to improve library management: (1) The adoption of a continuous integration system to provide evaluators 'instant' feedback on the quality of their evaluations and to provide data users with working 'beta' quality libraries in between major releases. (2) The transition to new hierarchical data format - the Generalized Nuclear Data (GND) format. We expect GND to enable new kinds of evaluated data which cannot be accommodated in the legacy ENDF format. (3) The development of data assimilation and uncertainty propagation techniques to enable the consistent use of integral experimental data in the evaluation process.« less

  3. 48 CFR 952.227-14 - Rights in data-general. (DOE coverage-alternates VI and VII)

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... (DOE coverage-alternates VI and VII) 952.227-14 Section 952.227-14 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES Text of Provisions and Clauses 952.227-14 Rights in data-general. (DOE coverage—alternates VI and VII) Alternate VI...

  4. 48 CFR 952.227-14 - Rights in data-general. (DOE coverage-alternates VI and VII)

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... (DOE coverage-alternates VI and VII) 952.227-14 Section 952.227-14 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES Text of Provisions and Clauses 952.227-14 Rights in data-general. (DOE coverage—alternates VI and VII) Alternate VI...

  5. 48 CFR 952.227-14 - Rights in data-general. (DOE coverage-alternates VI and VII)

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... (DOE coverage-alternates VI and VII) 952.227-14 Section 952.227-14 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES Text of Provisions and Clauses 952.227-14 Rights in data-general. (DOE coverage—alternates VI and VII) Alternate VI...

  6. Elevation of glycosaminoglycans in the amniotic fluid of a fetus with mucopolysaccharidosis VII

    PubMed Central

    Kubaski, Francyne; Brusius-Facchin, Ana Carolina; Mason, Robert W.; Patel, Pravin; Burin, Maira G.; Michelin-Tirelli, Kristiane; Kessler, Rejane Gus; Bender, Fernanda; Leistner-Segal, Sandra; Moreno, Carolina A.; Cavalcanti, Denise P.; Giugliani, Roberto; Tomatsu, Shunji

    2017-01-01

    Objective The aim of this study was to quantify GAGs in amniotic fluid (AF) from an MPS VII fetus compared with age-matched fetuses obtained from normal pregnancies. Method Disaccharides were measured by liquid chromatography tandem mass spectrometry (LC/MS/MS), compared to age-matched controls. Enzyme assay was performed in AF supernatant or cultured amniocytes. GUSB was analyzed by next generation sequencing using Ion Torrent Personal Genome Machine with a customized panel. Results No activity of β-glucuronidase was detected in fetal cells. The pregnancy was spontaneously terminated in the third trimester. Genetic studies identified a homozygous mutation of p.N379D (c.1135A>G) in the GUSB gene. LC/MS/MS showed that chondroitin sulfate, dermatan sulfate, heparan sulfate, and keratan sulfate levels were markedly increased in the MPS VII AF, compared to those in age-matched control AF (DS, HS, and C6S more than 10 × than age-matched controls; C4S and KS more than 3 times higher). Conclusion This is the first report of specific GAG analysis in AF from an MPS VII fetus, indicating that GAG elevation in AF occurs by 21 weeks of gestation and could be an additional tool for prenatal diagnosis of MPS VII and potentially other MPS types. PMID:28207930

  7. CASMO5 JENDL-4.0 and ENDF/B-VII.1beta4 libraries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rhodes, J.; Gheorghiu, N.; Ferrer, R.

    2012-07-01

    This paper details the generation of neutron data libraries for the CASMO5 lattice physics code based on the recently released JENDL-4.0 and ENDF/B-VII.1beta4 nuclear data evaluations. This data represents state-of-the-art nuclear data for late-2011. The key features of the new evaluations are briefly described along with the procedure for processing of this data into CASMO5, 586-energy group neutron data libraries. Finally some CASMO5 results for standard UO{sub 2} and MOX critical experiments for the two new libraries and the current ENDF/B-VII.0 CASMO5 library are presented including the B and W 1810 series, DIMPLE S06A, S06B, TCA reflector criticals with ironmore » plates and the PNL-30-35 MOX criticals. The results show that CASMO5 with the new libraries is performing well for these criticals with a very slight edge in results to the JENDL-4.0 nuclear data evaluation over the ENDF/B-VII.1beta4 evaluation. Work is currently underway to generate a CASMO5 library based on the final ENDF/B-VII.R1 evaluation released Dec. 22, 2011. (authors)« less

  8. Stereoscopic 3D reconstruction using motorized zoom lenses within an embedded system

    NASA Astrophysics Data System (ADS)

    Liu, Pengcheng; Willis, Andrew; Sui, Yunfeng

    2009-02-01

    This paper describes a novel embedded system capable of estimating 3D positions of surfaces viewed by a stereoscopic rig consisting of a pair of calibrated cameras. Novel theoretical and technical aspects of the system are tied to two aspects of the design that deviate from typical stereoscopic reconstruction systems: (1) incorporation of an 10x zoom lens (Rainbow- H10x8.5) and (2) implementation of the system on an embedded system. The system components include a DSP running μClinux, an embedded version of the Linux operating system, and an FPGA. The DSP orchestrates data flow within the system and performs complex computational tasks and the FPGA provides an interface to the system devices which consist of a CMOS camera pair and a pair of servo motors which rotate (pan) each camera. Calibration of the camera pair is accomplished using a collection of stereo images that view a common chess board calibration pattern for a set of pre-defined zoom positions. Calibration settings for an arbitrary zoom setting are estimated by interpolation of the camera parameters. A low-computational cost method for dense stereo matching is used to compute depth disparities for the stereo image pairs. Surface reconstruction is accomplished by classical triangulation of the matched points from the depth disparities. This article includes our methods and results for the following problems: (1) automatic computation of the focus and exposure settings for the lens and camera sensor, (2) calibration of the system for various zoom settings and (3) stereo reconstruction results for several free form objects.

  9. Optimizing dual-energy x-ray parameters for the ExacTrac clinical stereoscopic imaging system to enhance soft-tissue imaging.

    PubMed

    Bowman, Wesley A; Robar, James L; Sattarivand, Mike

    2017-03-01

    Stereoscopic x-ray image guided radiotherapy for lung tumors is often hindered by bone overlap and limited soft-tissue contrast. This study aims to evaluate the feasibility of dual-energy imaging techniques and to optimize parameters of the ExacTrac stereoscopic imaging system to enhance soft-tissue imaging for application to lung stereotactic body radiation therapy. Simulated spectra and a physical lung phantom were used to optimize filter material, thickness, tube potentials, and weighting factors to obtain bone subtracted dual-energy images. Spektr simulations were used to identify material in the atomic number range (3-83) based on a metric defined to separate spectra of high and low-energies. Both energies used the same filter due to time constraints of imaging in the presence of respiratory motion. The lung phantom contained bone, soft tissue, and tumor mimicking materials, and it was imaged with a filter thickness in the range of (0-0.7) mm and a kVp range of (60-80) for low energy and (120,140) for high energy. Optimal dual-energy weighting factors were obtained when the bone to soft-tissue contrast-to-noise ratio (CNR) was minimized. Optimal filter thickness and tube potential were achieved by maximizing tumor-to-background CNR. Using the optimized parameters, dual-energy images of an anthropomorphic Rando phantom with a spherical tumor mimicking material inserted in his lung were acquired and evaluated for bone subtraction and tumor contrast. Imaging dose was measured using the dual-energy technique with and without beam filtration and matched to that of a clinical conventional single energy technique. Tin was the material of choice for beam filtering providing the best energy separation, non-toxicity, and non-reactiveness. The best soft-tissue-weighted image in the lung phantom was obtained using 0.2 mm tin and (140, 60) kVp pair. Dual-energy images of the Rando phantom with the tin filter had noticeable improvement in bone elimination, tumor contrast

  10. Type VII collagen is enriched in the enamel organic matrix associated with the dentin-enamel junction of mature human teeth.

    PubMed

    McGuire, Jacob D; Walker, Mary P; Mousa, Ahmad; Wang, Yong; Gorski, Jeff P

    2014-06-01

    The inner enamel region of erupted teeth is known to exhibit higher fracture toughness and crack growth resistance than bulk phase enamel. However, an explanation for this behavior has been hampered by the lack of compositional information for the residual enamel organic matrix. Since enamel-forming ameloblasts are known to express type VII collagen and type VII collagen null mice display abnormal amelogenesis, the aim of this study was to determine whether type VII collagen is a component of the enamel organic matrix at the dentin-enamel junction (DEJ) of mature human teeth. Immunofluorescent confocal microscopy of demineralized tooth sections localized type VII collagen to the organic matrix surrounding individual enamel rods near the DEJ. Morphologically, immunoreactive type VII collagen helical-bundles resembled the gnarled-pattern of enamel rods detected by Coomassie Blue staining. Western blotting of whole crown or enamel matrix extracts also identified characteristic Mr=280 and 230 kDa type VII dimeric forms, which resolved into 75 and 25 kDa bands upon reduction. As expected, the collagenous domain of type VII collagen was resistant to pepsin digestion, but was susceptible to purified bacterial collagenase. These results demonstrate the inner enamel organic matrix in mature teeth contains macromolecular type VII collagen. Based on its physical association with the DEJ and its well-appreciated capacity to complex with other collagens, we hypothesize that enamel embedded type VII collagen fibrils may contribute not only to the structural resilience of enamel, but may also play a role in bonding enamel to dentin. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Type VII Collagen is Enriched in the Enamel Organic Matrix Associated with the Dentin-Enamel Junction of Mature Human Teeth

    PubMed Central

    McGuire, Jacob D.; Walker, Mary P.; Mousa, Ahmad; Wang, Yong; Gorski, Jeff P.

    2014-01-01

    The inner enamel region of erupted teeth is known to exhibit higher fracture toughness and crack growth resistance than bulk phase enamel. However, an explanation for this behavior has been hampered by the lack of compositional information for the residual enamel organic matrix. Since enamel-forming ameloblasts are known to express type VII collagen and type VII collagen null mice display abnormal amelogenesis, the aim of this study was to determine whether type VII collagen is a component of the enamel organic matrix at the dentin-enamel junction (DEJ) of mature human teeth. Immunofluorescent confocal microscopy of demineralized tooth sections localized type VII collagen to the organic matrix surrounding individual enamel rods near the DEJ. Morphologically, immunoreactive type VII collagen helical-bundles resembled the gnarled-pattern of enamel rods detected by Coomassie Blue staining. Western blotting of whole crown or enamel matrix extracts also identified characteristic Mr=280 and 230 kDa type VII dimeric forms, which resolved into 75 and 25 kDa bands upon reduction. As expected, the collagenous domain of type VII collagen was resistant to pepsin digestion, but was susceptible to purified bacterial collagenase. These results demonstrate the inner enamel organic matrix in mature teeth contains macromolecular type VII collagen. Based on its physical association with the DEJ and its well-appreciated capacity to complex with other collagens, we hypothesize that enamel embedded type VII collagen fibrils may contribute not only to the structural resilience of enamel, but may also play a role in bonding enamel to dentin. PMID:24594343

  12. Head-coupled remote stereoscopic camera system for telepresence applications

    NASA Astrophysics Data System (ADS)

    Bolas, Mark T.; Fisher, Scott S.

    1990-09-01

    The Virtual Environment Workstation Project (VIEW) at NASA's Ames Research Center has developed a remotely controlled stereoscopic camera system that can be used for telepresence research and as a tool to develop and evaluate configurations for head-coupled visual systems associated with space station telerobots and remote manipulation robotic arms. The prototype camera system consists of two lightweight CCD video cameras mounted on a computer controlled platform that provides real-time pan, tilt, and roll control of the camera system in coordination with head position transmitted from the user. This paper provides an overall system description focused on the design and implementation of the camera and platform hardware configuration and the development of control software. Results of preliminary performance evaluations are reported with emphasis on engineering and mechanical design issues and discussion of related psychophysiological effects and objectives.

  13. Demonstration of resonant photopumping of Mo VII by Mo XII for a VUV laser near 600 {Angstrom}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ilcisin, K.J.; Aumayr, F.; Schwob, J.L.

    1993-09-01

    We present data of experiments on the resonant photopumping of Mo VII by Mo XII as a method of generating a coherent VUV source near 600 {angstrom}. The experiment is based on a scheme proposed by Feldman and Reader in which the 4p{sup 6} -- 4p{sup 5}6s transition in Mo VII in resonantly photopumped by the 5s {sup 2}S{sub 1/2} -- 4p {sup 2}P{sub 1/2} transition in Mo XII. Results of the laser produced plasma experiments show the successful enhancement of the population of the Mo VII 4p{sup 5}6s upper lasing level when pumped by an adjacent Mo VII plasma.more » No enhancement was seen in a control experiment where the Mo VII plasma was pumped by a Zr X plasma. Improvements of the intensity of the Mo XII pump source, achieved using an additional pump laser, lead to the generation of a population inversion for the VUV transition.« less

  14. Emission line spectra of S VII ? S XIV in the 20 ? 75 ? wavelength region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lepson, J K; Beiersdorfer, P; Behar, E

    As part of a larger project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, the authors present observations of sulfur lines in the soft X-ray and extreme ultraviolet regions. The database includes wavelength measurements with standard errors, relative intensities, and line assignments for 127 transitions of S VII through S XIV between 20 and 75 {angstrom}. The experimental data are complemented with a full set of calculations using the Hebrew University Lawrence Livermore Atomic Code (HULLAC). A comparison of the laboratorymore » data with Chandra measurements of Procyon allows them to identify S VII-S XI lines.« less

  15. Prophylactic Level VII Nodal Dissection as a Prognostic Factor in Papillary Thyroid Carcinoma: a Pilot Study of 27 Patients.

    PubMed

    Fayek, Ihab Samy

    2015-01-01

    Prognostic value of prophylactic level VII nodal dissection in papillary thyroid carcinoma has been highlighted. A total of 27 patients with papillary thyroid carcinoma with N0 neck underwent total thyroidectomy with level VI and VII nodal dissection through same collar neck incision. Multicentricity, bilaterality, extrathyroidal extension, level VI and VII lymph nodes were studied as separate and independent prognostic factors for DFS at 24 months. 21 females and 6 males with a mean age of 34.6 years old, tumor size was 5-24 mm. (mean 12.4 mm.), multicentricity in 11 patients 2-4 foci (mean 2.7), bilaterality in 8 patients and extrathyroidal extension in 8 patients. Dissected level VI LNs 2-8 (mean 5 LNs) and level VII LNs 1-4 (mean 1.9). Metastatic level VI LNs 0-3 (mean 1) and level VII LNs 0-2 (mean 0.5). Follow-up from 6-51 months (mean 25.6) with 7 patients showed recurrence (3 local and 4 distant). Cumulative DFS at 24 months was 87.8% and was significantly affected in relation to bilaterality (p-value<0.001), extrathyroidal extension (p-value<0.001), level VI positive ((p-value<0.001) and level VII positive ((p-value<0.001) LNs. No recurrences were detected during the follow-up period in the absence of level VI and level VII nodal involvement. Level VII prophylactic nodal dissection is an important and integral prognostic factor in papillary thyroid carcinoma. A larger multicenter study is crucial to reach a satisfactory conclusion about the necessity and safety of this approach.

  16. The adenovirus major core protein VII is dispensable for virion assembly but is essential for lytic infection

    PubMed Central

    Suomalainen, Maarit; Zheng, Yueting; Boucke, Karin

    2017-01-01

    The Adenovirus (Ad) genome within the capsid is tightly associated with a virus-encoded, histone-like core protein—protein VII. Two other Ad core proteins, V and X/μ, also are located within the virion and are loosely associated with viral DNA. Core protein VII remains associated with the Ad genome during the early phase of infection. It is not known if naked Ad DNA is packaged into the capsid, as with dsDNA bacteriophage and herpesviruses, followed by the encapsidation of viral core proteins, or if a unique packaging mechanism exists with Ad where a DNA-protein complex is simultaneously packaged into the virion. The latter model would require an entirely new molecular mechanism for packaging compared to known viral packaging motors. We characterized a virus with a conditional knockout of core protein VII. Remarkably, virus particles were assembled efficiently in the absence of protein VII. No changes in protein composition were evident with VII−virus particles, including the abundance of core protein V, but changes in the proteolytic processing of some capsid proteins were evident. Virus particles that lack protein VII enter the cell, but incoming virions did not escape efficiently from endosomes. This greatly diminished all subsequent aspects of the infectious cycle. These results reveal that the Ad major core protein VII is not required to condense viral DNA within the capsid, but rather plays an unexpected role during virus maturation and the early stages of infection. These results establish a new paradigm pertaining to the Ad assembly mechanism and reveal a new and important role of protein VII in early stages of infection. PMID:28628648

  17. Effective treatment of chemoresistant breast cancer in vitro and in vivo by a factor VII-targeted photodynamic therapy.

    PubMed

    Duanmu, J; Cheng, J; Xu, J; Booth, C J; Hu, Z

    2011-04-26

    The purpose of this study was to test a novel, dual tumour vascular endothelial cell (VEC)- and tumour cell-targeting factor VII-targeted Sn(IV) chlorin e6 photodynamic therapy (fVII-tPDT) by targeting a receptor tissue factor (TF) as an alternative treatment for chemoresistant breast cancer using a multidrug resistant (MDR) breast cancer line MCF-7/MDR. The TF expression by the MCF-7/MDR breast cancer cells and tumour VECs in MCF-7/MDR tumours from mice was determined separately by flow cytometry and immunohistochemistry using anti-human or anti-murine TF antibodies. The efficacy of fVII-tPDT was tested in vitro and in vivo and was compared with non-targeted PDT for treatment of chemoresistant breast cancer. The in vitro efficacy was determined by a non-clonogenic assay using crystal violet staining for monolayers, and apoptosis and necrosis were assayed to elucidate the underlying mechanisms. The in vivo efficacy of fVII-tPDT was determined in a nude mouse model of subcutaneous MCF-7/MDR tumour xenograft by measuring tumour volume. To our knowledge, this is the first presentation showing that TF was expressed on tumour VECs in chemoresistant breast tumours from mice. The in vitro efficacy of fVII-tPDT was 12-fold stronger than that of ntPDT for MCF-7/MDR cancer cells, and the mechanism of action involved induction of apoptosis and necrosis. Moreover, fVII-tPDT was effective and safe for the treatment of chemoresistant breast tumours in the nude mouse model. We conclude that fVII-tPDT is effective and safe for the treatment of chemoresistant breast cancer, presumably by simultaneously targeting both the tumour neovasculature and chemoresistant cancer cells. Thus, this dual-targeting fVII-tPDT could also have therapeutic potential for the treatment of other chemoresistant cancers.

  18. Subjective evaluation of two stereoscopic imaging systems exploiting visual attention to improve 3D quality of experience

    NASA Astrophysics Data System (ADS)

    Hanhart, Philippe; Ebrahimi, Touradj

    2014-03-01

    Crosstalk and vergence-accommodation rivalry negatively impact the quality of experience (QoE) provided by stereoscopic displays. However, exploiting visual attention and adapting the 3D rendering process on the fly can reduce these drawbacks. In this paper, we propose and evaluate two different approaches that exploit visual attention to improve 3D QoE on stereoscopic displays: an offline system, which uses a saliency map to predict gaze position, and an online system, which uses a remote eye tracking system to measure real time gaze positions. The gaze points were used in conjunction with the disparity map to extract the disparity of the object-of-interest. Horizontal image translation was performed to bring the fixated object on the screen plane. The user preference between standard 3D mode and the two proposed systems was evaluated through a subjective evaluation. Results show that exploiting visual attention significantly improves image quality and visual comfort, with a slight advantage for real time gaze determination. Depth quality is also improved, but the difference is not significant.

  19. Antimicrobial peptide scolopendrasin VII, derived from the centipede Scolopendra subspinipes mutilans, stimulates macrophage chemotaxis via formyl peptide receptor 1

    PubMed Central

    Park, Yoo Jung; Lee, Ha Young; Jung, Young Su; Park, Joon Seong; Hwang, Jae Sam; Bae, Yoe-Sik

    2015-01-01

    In this study, we report that one of the antimicrobial peptides scolopendrasin VII, derived from Scolopendra subspinipes mutilans, stimulates actin polymerization and the subsequent chemotactic migration of macrophages through the activation of ERK and protein kinase B (Akt) activity. The scolopendrasin VII-induced chemotactic migration of macrophages is inhibited by the formyl peptide receptor 1 (FPR1) antagonist cyclosporine H. We also found that scolopendrasin VII stimulate the chemotactic migration of FPR1-transfected RBL-2H3 cells, but not that of vector-transfected cells; moreover, scolopendrasin VII directly binds to FPR1. Our findings therefore suggest that the antimicrobial peptide scolopendrasin VII, derived from Scolopendra subspinipes mutilans, stimulates macrophages, resulting in chemotactic migration via FPR1 signaling, and the peptide can be useful in the study of FPR1-related biological responses. [BMB Reports 2015; 48(8): 479-484] PMID:26129676

  20. ADRPM-VII applied to the long-range acoustic detection problem

    NASA Technical Reports Server (NTRS)

    Shalis, Edward; Koenig, Gerald

    1990-01-01

    An acoustic detection range prediction model (ADRPM-VII) has been written for IBM PC/AT machines running on the MS-DOS operating system. The software allows the user to predict detection distances of ground combat vehicles and their associated targets when they are involved in quasi-military settings. The program can also calculate individual attenuation losses due to spherical spreading, atmospheric absorption, ground reflection and atmospheric refraction due to temperature and wind gradients while varying parameters effecting the source-receiver problem. The purpose here is to examine the strengths and limitations of ADRPM-VII by modeling the losses due to atmospheric refraction and ground absorption, commonly known as excess attenuation, when applied to the long range detection problem for distances greater than 3 kilometers.

  1. Evaluation of off-label recombinant activated factor VII for multiple indications in children.

    PubMed

    Reiter, Pamela D; Valuck, Robert J; Taylor, Ruston S

    2007-07-01

    Despite a paucity of safety and efficacy data, the use of recombinant activated factor VII in children for off-label indications has now surpassed its use in hemophilia. A retrospective chart review was conducted of 46 subjects (age, 6.7 +/- 6 years; weight, 26 +/- 20 kg) who received recombinant activated factor VII for nonhemophiliac indications between January 1, 2004, and September 1, 2005. Indications for use included prevention (n = 6) or treatment (n = 40) of bleeding due to general surgery, hepatic failure, gastrointestinal bleeding, severe traumatic brain injury, bone marrow transplant, cardiac, acetaminophen overdose, and multiorgan system failure. Decreases in prothrombin time, partial thromboplastin time, and international normalized ratio were observed. No inappropriate thrombotic events were noted. Administration of recombinant activated factor VII was associated with a reduction in coagulation markers without obvious adverse thrombotic events at cost of $4189 per dose. These findings should be confirmed in a prospective trial.

  2. Stereoscopic augmented reality with pseudo-realistic global illumination effects

    NASA Astrophysics Data System (ADS)

    de Sorbier, Francois; Saito, Hideo

    2014-03-01

    Recently, augmented reality has become very popular and has appeared in our daily life with gaming, guiding systems or mobile phone applications. However, inserting object in such a way their appearance seems natural is still an issue, especially in an unknown environment. This paper presents a framework that demonstrates the capabilities of Kinect for convincing augmented reality in an unknown environment. Rather than pre-computing a reconstruction of the scene like proposed by most of the previous method, we propose a dynamic capture of the scene that allows adapting to live changes of the environment. Our approach, based on the update of an environment map, can also detect the position of the light sources. Combining information from the environment map, the light sources and the camera tracking, we can display virtual objects using stereoscopic devices with global illumination effects such as diffuse and mirror reflections, refractions and shadows in real time.

  3. Title VII Sexual Harassment Guidelines and Educational Employment [and] What Can Students Do About Sex Discrimination?

    ERIC Educational Resources Information Center

    Howard, Susan; And Others

    Guidelines concerning sexual harassment of employees at educational institutions under Title VII of the Civil Rights Act of 1964 are considered. November 1980 final interpretive guidelines issued by the Equal Employment Opportunity Commission state that Title VII prohibits sexual harassment of employees, that employers are responsible for the…

  4. A rare combination: congenital factor VII deficiency with Chiari malformation.

    PubMed

    Bay, Ali; Aktekin, Elif; Erkutlu, Ibrahim

    2015-12-01

    Congenital factor (VII) deficiency is a rare bleeding disorder. We present a patient with congenital FVII deficiency and congenital hydrocephalus who underwent a ventriculoperitoneal shunt operation and needed no prophylaxis after the procedure.

  5. Consciousness and stereoscopic environmental imaging

    NASA Astrophysics Data System (ADS)

    Mason, Steve

    2014-02-01

    The question of human consciousness has intrigued philosophers and scientists for centuries: its nature, how we perceive our environment, how we think, our very awareness of thought and self. It has been suggested that stereoscopic vision is "a paradigm of how the mind works" 1 In depth perception, laws of perspective are known, reasoned, committed to memory from an early age; stereopsis, on the other hand, is a 3D experience governed by strict laws but actively joined within the brain―one sees it without explanation. How do we, in fact, process two different images into one 3D module within the mind and does an awareness of this process give us insight into the workings of our own consciousness? To translate this idea to imaging I employed ChromaDepth™ 3D glasses that rely on light being refracted in a different direction for each eye―colors of differing wavelengths appearing at varying distances from the viewer resulting in a 3D space. This involves neither calculation nor manufacture of two images or views. Environmental spatial imaging was developed―a 3D image was generated that literally surrounds the viewer. The image was printed and adhered to a semi-circular mount; the viewer then entered the interior to experience colored shapes suspended in a 3D space with an apparent loss of surface, or picture plane, upon which the image is rendered. By focusing our awareness through perception-based imaging we are able to gain a deeper understanding of how the brain works, how we see.

  6. Investigating the air oxidation of V(II) ions in a vanadium redox flow battery

    NASA Astrophysics Data System (ADS)

    Ngamsai, Kittima; Arpornwichanop, Amornchai

    2015-11-01

    The air oxidation of vanadium (V(II)) ions in a negative electrolyte reservoir is a major side reaction in a vanadium redox flow battery (VRB), which leads to electrolyte imbalance and self-discharge of the system during long-term operation. In this study, an 80% charged negative electrolyte solution is employed to investigate the mechanism and influential factors of the reaction in a negative-electrolyte reservoir. The results show that the air oxidation of V(II) ions occurs at the air-electrolyte solution interface area and leads to a concentration gradient of vanadium ions in the electrolyte solution and to the diffusion of V(II) and V(III) ions. The effect of the ratio of the electrolyte volume to the air-electrolyte solution interface area and the concentrations of vanadium and sulfuric acid in an electrolyte solution is investigated. A higher ratio of electrolyte volume to the air-electrolyte solution interface area results in a slower oxidation reaction rate. The high concentrations of vanadium and sulfuric acid solution also retard the air oxidation of V(II) ions. This information can be utilized to design an appropriate electrolyte reservoir for the VRB system and to prepare suitable ingredients for the electrolyte solution.

  7. Turning Back the Title VII Clock: The Resegregation of the American Work Force through Validity Generalization.

    ERIC Educational Resources Information Center

    Goldstein, Barry L.; Patterson, Patrick O.

    1988-01-01

    Refers to Title VII of the Civil Rights Act of 1964 and the Supreme Court's disparate impact interpretation of Title VII in Griggs versus Duke Power Company. Contends that attacks on the Griggs decision are legally unsound and that claims made by advocates of validity generalization are scientifically unsupported. (Author/NB)

  8. Survey of Land-Grant Colleges and Universities. Bulletin, 1930, No. 9. Volume II. [Part VII - Index

    ERIC Educational Resources Information Center

    Office of Education, United States Department of the Interior, 1930

    1930-01-01

    The attached document covers the concluding sections of the second volume of the Survey of Land-Grant Colleges and Universities: Part VII through the index. Part VII, Extension services, is divided into the following sections: (1) Introduction; (2) Position and objectives of Smith-Lever cooperative extension; (3) Administrative organization of…

  9. Title VII funding is associated with more family physicians and more physicians serving the underserved.

    PubMed

    Meyers, D; Fryer, G E; Krol, D; Phillips, R L; Green, L A; Dovey, S M

    2002-08-15

    Title VII funding of departments of family medicine at U.S. medical schools is significantly associated with expansion of the primary care physician workforce and increased accessibility to physicians for the residents of rural and underserved areas. Title VII has been successful in achieving its stated goals and has had an important role in addressing U.S. physician workforce policy issues.

  10. Composition, apparatus, and process, for sorption of gaseous compounds of group II-VII elements

    DOEpatents

    Tom, Glenn M.; McManus, James V.; Luxon, Bruce A.

    1991-08-06

    Scavenger compositions are disclosed, which have utility for effecting the sorptive removal of hazardous gases containing Group II-VII elements of the Periodic Table, such as are widely encountered in the manufacture of semiconducting materials and semiconductor devices. Gas sorption processes including the contacting of Group II-VII gaseous compounds with such scavenger compositions are likewise disclosed, together with critical space velocity contacting conditions pertaining thereto. Further described are gas contacting apparatus, including mesh structures which may be deployed in gas contacting vessels containing such scavenger compositions, to prevent solids from being introduced to or discharged from the contacting vessel in the gas stream undergoing treatment. A reticulate heat transfer structure also is disclosed, for dampening localized exothermic reaction fronts when gas mixtures comprising Group II-VII constituents are contacted with the scavenger compositions in bulk sorption contacting vessels according to the invention.

  11. 77 FR 14516 - Lock+ Hydro Friends Fund VII; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-12

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 14339-000] Lock+ Hydro Friends Fund VII; Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications On December 22, 2011, Lock+ Hydro Friends Fund VII filed...

  12. Development of a stereoscopic three-dimensional drawing application

    NASA Astrophysics Data System (ADS)

    Carver, Donald E.; McAllister, David F.

    1991-08-01

    With recent advances in 3-D technology, computer users have the opportunity to work within a natural 3-D environment; a flat panel LCD computer display of this type, the DTI-100M made by Dimension Technologies, Inc., recently went on the market. In a joint venture between DTI and NCSU, an object-oriented 3-D drawing application, 3-D Draw, was developed to address some issues of human interface design for interactive stereo drawing applications. The focus of this paper is to determine some of the procedures a user would naturally expect to follow while working within a true 3-D environment. The paper discusses (1) the interface between the Macintosh II and DTI-100M during implementation of 3-D Draw, including stereo cursor development and presentation of current 2-D systems, with an additional `depth'' parameter, in the 3-D world, (2) problems in general for human interface into the 3-D environment, and (3) necessary functions and/or problems in developing future stereoscopic 3-D operating systems/tools.

  13. Human Adenovirus Infection Causes Cellular E3 Ubiquitin Ligase MKRN1 Degradation Involving the Viral Core Protein pVII.

    PubMed

    Inturi, Raviteja; Mun, Kwangchol; Singethan, Katrin; Schreiner, Sabrina; Punga, Tanel

    2018-02-01

    Human adenoviruses (HAdVs) are common human pathogens encoding a highly abundant histone-like core protein, VII, which is involved in nuclear delivery and protection of viral DNA as well as in sequestering immune danger signals in infected cells. The molecular details of how protein VII acts as a multifunctional protein have remained to a large extent enigmatic. Here we report the identification of several cellular proteins interacting with the precursor pVII protein. We show that the cellular E3 ubiquitin ligase MKRN1 is a novel precursor pVII-interacting protein in HAdV-C5-infected cells. Surprisingly, the endogenous MKRN1 protein underwent proteasomal degradation during the late phase of HAdV-C5 infection in various human cell lines. MKRN1 protein degradation occurred independently of the HAdV E1B55K and E4orf6 proteins. We provide experimental evidence that the precursor pVII protein binding enhances MKRN1 self-ubiquitination, whereas the processed mature VII protein is deficient in this function. Based on these data, we propose that the pVII protein binding promotes MKRN1 self-ubiquitination, followed by proteasomal degradation of the MKRN1 protein, in HAdV-C5-infected cells. In addition, we show that measles virus and vesicular stomatitis virus infections reduce the MKRN1 protein accumulation in the recipient cells. Taken together, our results expand the functional repertoire of the HAdV-C5 precursor pVII protein in lytic virus infection and highlight MKRN1 as a potential common target during different virus infections. IMPORTANCE Human adenoviruses (HAdVs) are common pathogens causing a wide range of diseases. To achieve pathogenicity, HAdVs have to counteract a variety of host cell antiviral defense systems, which would otherwise hamper virus replication. In this study, we show that the HAdV-C5 histone-like core protein pVII binds to and promotes self-ubiquitination of a cellular E3 ubiquitin ligase named MKRN1. This mutual interaction between the pVII and

  14. 25 CFR 36.22 - Standard VII-Elementary instructional program.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 1 2012-04-01 2011-04-01 true Standard VII-Elementary instructional program. 36.22 Section 36.22 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION MINIMUM ACADEMIC STANDARDS FOR THE BASIC EDUCATION OF INDIAN CHILDREN AND NATIONAL CRITERIA FOR DORMITORY SITUATIONS Minimum...

  15. 25 CFR 36.22 - Standard VII-Elementary instructional program.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 1 2013-04-01 2013-04-01 false Standard VII-Elementary instructional program. 36.22 Section 36.22 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION MINIMUM ACADEMIC STANDARDS FOR THE BASIC EDUCATION OF INDIAN CHILDREN AND NATIONAL CRITERIA FOR DORMITORY SITUATIONS Minimum...

  16. 25 CFR 36.22 - Standard VII-Elementary instructional program.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 1 2014-04-01 2014-04-01 false Standard VII-Elementary instructional program. 36.22 Section 36.22 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR EDUCATION MINIMUM ACADEMIC STANDARDS FOR THE BASIC EDUCATION OF INDIAN CHILDREN AND NATIONAL CRITERIA FOR DORMITORY SITUATIONS Minimum...

  17. Synthesis and characterization of (18)F-labeled active site inhibited factor VII (ASIS).

    PubMed

    Erlandsson, Maria; Nielsen, Carsten H; Jeppesen, Troels E; Kristensen, Jesper B; Petersen, Lars C; Madsen, Jacob; Kjaer, Andreas

    2015-05-15

    Activated factor VII blocked in the active site with Phe-Phe-Arg-chloromethyl ketone (active site inhibited factor VII (ASIS)) is a 50-kDa protein that binds with high affinity to its receptor, tissue factor (TF). TF is a transmembrane glycoprotein that plays an important role in, for example, thrombosis, metastasis, tumor growth, and tumor angiogenesis. The aim of this study was to develop an (18)F-labeled ASIS derivative to assess TF expression in tumors. Active site inhibited factor VII was labeled using N-succinimidyl-4-[(18)F]fluorobenzoate, and the [(18)F]ASIS was purified on a PD-10 desalting column. The radiochemical yield was 25 ± 6%, the radiochemical purity was >97%, and the pseudospecific radioactivity was 35 ± 9 GBq/µmol. The binding efficacy was evaluated in pull-down experiments, which monitored the binding of unlabeled ASIS and [(18)F]ASIS to TF and to a specific anti-factor VII antibody (F1A2-mAb). No significant difference in binding efficacy between [(18)F]ASIS and ASIS could be detected. Furthermore, [(18)F]ASIS was relatively stable in vitro and in vivo in mice. In conclusion, [(18)F]ASIS has for the first time been successfully synthesized as a possible positron emission tomography tracer to image TF expression levels. In vivo positron emission tomography studies to evaluate the full potential of [(18)F]ASIS are in progress. Copyright © 2015 John Wiley & Sons, Ltd.

  18. a New ENDF/B-VII.0 Based Multigroup Cross-Section Library for Reactor Dosimetry

    NASA Astrophysics Data System (ADS)

    Alpan, F. A.; Anderson, S. L.

    2009-08-01

    The latest of the ENDF/B libraries, ENDF/B-VII.0 was released in December 2006. In this paper, the ENDF/B-VII.O evaluations were used in generating a new coupled neutron/gamma multigroup library having the same group structure of VITAMIN-B6, i.e., the 199-neutron, 42-gamma group library. The new library was generated utilizing NJOY99.259 for pre-processing and the AMPX modules for post-processing of cross sections. An ENDF/B-VI.3 based VITAMIN-B6-like library was also generated. The fine-group libraries and the ENDF/B-VI.3 based 47-neutron, 20-gamma group BUGLE-96 library were used with the discrete ordinates code DORT to obtain a three-dimensional synthesized flux distribution from r, r-θ, and r-z models for a standard Westinghouse 3-loop design reactor. Reaction rates were calculated for ex-vessel neutron dosimetry containing 63Cu(n,α)60Co, 46Ti(n,p)46Sc, 54Fe(n,P)54Mn, 58Ni(n,P)58Co, 238U(n,f)137Cs, 237Np(n,f)137Cs, and 59Co(n,γ)60Co (bare and cadmium covered) reactions. Results were compared to measurements. In comparing the 199-neutron, 42-gamma group ENDF/B-VI.3 and ENDF/B-VII.O libraries, it was observed that the ENDF/B-VI.3 based library results were in better agreement with measurements. There is a maximum difference of 7% (for the 63Cu(n,α)60Co reaction rate calculation) between ENDF/B-VI.3 and ENDF/B-VII.O. Differences between ENDF/B-VI.3 and ENDF/B-VII.O libraries are due to 16O, 1H, 90Zr, 91Zr, 92Zr, 238U, and 239Pu evaluations. Both ENDF/B-VI.3 and ENDF/B-VII.O library calculated reaction rates are within 20% of measurement and meet the criterion specified in the U. S. Nuclear Regulatory Commission Regulatory Guide 1.190, "Calculational and Dosimetry Methods for Determining Pressure Vessel Neutron Fluence."

  19. Adenovirus core protein VII contains distinct sequences that mediate targeting to the nucleus and nucleolus, and colocalization with human chromosomes.

    PubMed

    Lee, Tim W R; Blair, G Eric; Matthews, David A

    2003-12-01

    During adenovirus infection, following capsid dissociation, core protein VII enters the host cell nucleus complexed with adenovirus DNA. In order to determine whether protein VII may have an active role in this nuclear import, regions of the preVII gene were amplified by PCR, and further oligonucleotide mutants were designed with site-directed mutation of codons for the basic amino acids arginine and lysine. Fragments were cloned into a mammalian expression plasmid to express the peptides as N-terminal fusions to enhanced green fluorescent protein. Results demonstrate that preVII protein contains both nuclear and nucleolar targeting sequences. Such signals may be important in the delivery of adenovirus DNA to the host cell nucleus during adenovirus infection. Furthermore, the data suggest that protein VII may bind to human chromosomes by means of two distinct domains, one sharing homology with the N-terminal regulatory tail of histone H3.

  20. 76 FR 24471 - Qualified Hydro 26, LLC; Lock+ Hydro Friends Fund VII; Western Minnesota Municipal Power Agency...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-02

    ...; 14113-000] Qualified Hydro 26, LLC; Lock+ Hydro Friends Fund VII; Western Minnesota Municipal Power... Hydro), Lock+ Hydro Friends Fund VII (Hydro Friends) and Western Minnesota Municipal Power Agency (WMMPA... 02114; (978) 283-2822. Hydro Friends' proposed Lock and Dam 11 Hydropower Project No. 14112 would...

  1. Recordkeeping and reporting under Title VII and the ADA--EEOC. Final rule.

    PubMed

    1991-07-26

    This final rule is based on two separate Notices of Proposed Rulemaking (NPRM) published on February 13, 1989 (54 FR 6551), and March 5, 1991 (56 FR 9185). This final rule amends 29 CFR part 1602, EEOC's regulations on Recordkeeping and Reporting under title VII of the Civil Rights Act of 1964 (title VII), to add recordkeeping requirements under the Americans with Disabilities Act of 1990 (ADA). It increases the records retention period required in part 1602 for title VII and the ADA from 6 months to one year. The Commission also is adding a new subpart R to part 1602, 29 CFR 1602.56, that will clarify that the Commission has the authority to investigate persons to determine whether they comply with the reporting or recordkeeping requirements of part 1602. In addition, the Commission is making several minor changes to sections 1602.7 and 1602.10. The Commission also is deleting section 1602.14(b) of its title VII recordkeeping regulations, which provides that the section 1602 recordkeeping requirements do not apply to temporary or seasonal positions. Information regarding such employees now must be reported on Standard Form 100 on September 30 of each year, in the same fashion as information regarding permanent employees is reported. Similarly, the Commission is deleting sections 1627.3(b) and 1627.4(a)(2) of the Age Discrimination in Employment Act recordkeeping regulations, which provide for a 90-day retention period for temporary positions, and is clarifying the mandatory nature of such recordkeeping. The Commission is not issuing a final rule on proposed section 1602.57 at this time.

  2. Clinically Normal Stereopsis Does Not Ensure a Performance Benefit from Stereoscopic 3D Depth Cues

    NASA Astrophysics Data System (ADS)

    McIntire, John P.; Havig, Paul R.; Harrington, Lawrence K.; Wright, Steve T.; Watamaniuk, Scott N. J.; Heft, Eric L.

    2014-09-01

    To investigate the effect of manipulating disparity on task performance and viewing comfort, twelve participants were tested on a virtual object precision placement task while viewing a stereoscopic 3D (S3D) display. All participants had normal or corrected-to-normal visual acuity, passed the Titmus stereovision clinical test, and demonstrated normal binocular function, including phorias and binocular fusion ranges. Each participant completed six experimental sessions with different maximum binocular disparity limits. The results for ten of the twelve participants were generally as expected, demonstrating a large performance advantage when S3D cues were provided. The sessions with the larger disparity limits typically resulted in the best performance, and the sessions with no S3D cues the poorest performance. However, one participant demonstrated poorer performance in sessions with smaller disparity limits but improved performance in sessions with the larger disparity limits. Another participant's performance declined whenever any S3D cues were provided. Follow-up testing suggested that the phenomenon of pseudo-stereoanomaly may account for one viewer's atypical performance, while the phenomenon of stereoanomaly might account for the other. Overall, the results demonstrate that a subset of viewers with clinically normal binocular and stereoscopic vision may have difficulty performing depth-related tasks on S3D displays. The possibility of the vergence-accommodation conflict contributing to individual performance differences is also discussed.

  3. Quantitative analysis of the synthesis and secretion of type VII collagen in cultured human dermal fibroblasts with a sensitive sandwich enzyme-linked immunoassay.

    PubMed

    Amano, Satoshi; Ogura, Yuki; Akutsu, Nobuko; Nishiyama, Toshio

    2007-02-01

    Type VII collagen is the major component of anchoring fibrils in the epidermal basement membrane. Its expression has been analyzed by immunostaining or Northern blotting, but rarely at the protein level. In this study, we have quantitatively examined the effects of ascorbic acid and various cytokines/growth factors on the protein synthesis and secretion of type VII collagen by human dermal fibroblasts in culture, using a developed, highly sensitive sandwich enzyme-linked immunoassay with two kinds of specific monoclonal antibodies against the non-collagenous domain-1. Ascorbic acid and its derivative induced a twofold increase in type VII collagen synthesis, and markedly increased the secretion of type VII collagen into the medium when compared with the control culture. This effect was not influenced by the presence of transforming growth factor-beta1 (TGF-beta1). The synthesis of type VII collagen was elevated by TGF-beta1, platelet-derived growth factor, tumor necrosis factor-alpha, and interleukin-1beta, but not by TGF-alpha. Thus, our data indicate that the synthesis and secretion of type VII collagen in human dermal fibroblasts are regulated by ascorbate and the enhancement of type VII collagen gene expression by cytokines/growth factors is accompanied with elevated production of type VII collagen at the protein level.

  4. Alternation frequency thresholds for stereopsis as a technique for exploring stereoscopic difficulties

    PubMed Central

    Rychkova, Svetlana; Ninio, Jacques

    2011-01-01

    When stereoscopic images are presented alternately to the two eyes, stereopsis occurs at F ≥ 1 Hz full-cycle frequencies for very simple stimuli, and F ≥ 3 Hz full-cycle frequencies for random-dot stereograms (eg Ludwig I, Pieper W, Lachnit H, 2007 “Temporal integration of monocular images separated in time: stereopsis, stereoacuity, and binocular luster” Perception & Psychophysics 69 92–102). Using twenty different stereograms presented through liquid crystal shutters, we studied the transition to stereopsis with fifteen subjects. The onset of stereopsis was observed during a stepwise increase of the alternation frequency, and its disappearance was observed during a stepwise decrease in frequency. The lowest F values (around 2.5 Hz) were observed with stimuli involving two to four simple disjoint elements (circles, arcs, rectangles). Higher F values were needed for stimuli containing slanted elements or curved surfaces (about 1 Hz increment), overlapping elements at two different depths (about 2.5 Hz increment), or camouflaged overlapping surfaces (> 7 Hz increment). A textured cylindrical surface with a horizontal axis appeared easier to interpret (5.7 Hz) than a pair of slanted segments separated in depth but forming a cross in projection (8 Hz). Training effects were minimal, and F usually increased as disparities were reduced. The hierarchy of difficulties revealed in the study may shed light on various problems that the brain needs to solve during stereoscopic interpretation. During the construction of the three-dimensional percept, the loss of information due to natural decay of the stimuli traces must be compensated by refreshes of visual input. In the discussion an attempt is made to link our results with recent advances in the comprehension of visual scene memory. PMID:23145225

  5. Expanding the versatility of phage display I: efficient display of peptide-tags on protein VII of the filamentous phage.

    PubMed

    Løset, Geir Åge; Bogen, Bjarne; Sandlie, Inger

    2011-02-24

    Phage display is a platform for selection of specific binding molecules and this is a clear-cut motivation for increasing its performance. Polypeptides are normally displayed as fusions to the major coat protein VIII (pVIII), or the minor coat protein III (pIII). Display on other coat proteins such as pVII allows for display of heterologous peptide sequences on the virions in addition to those displayed on pIII and pVIII. In addition, pVII display is an alternative to pIII or pVIII display. Here we demonstrate how standard pIII or pVIII display phagemids are complemented with a helper phage which supports production of virions that are tagged with octa FLAG, HIS(6) or AviTag on pVII. The periplasmic signal sequence required for pIII and pVIII display, and which has been added to pVII in earlier studies, is omitted altogether. Tagging on pVII is an important and very useful add-on feature to standard pIII and pVII display. Any phagemid bearing a protein of interest on either pIII or pVIII can be tagged with any of the tags depending simply on choice of helper phage. We show in this paper how such tags may be utilized for immobilization and separation as well as purification and detection of monoclonal and polyclonal phage populations.

  6. Real-time photorealistic stereoscopic rendering of fire

    NASA Astrophysics Data System (ADS)

    Rose, Benjamin M.; McAllister, David F.

    2007-02-01

    We propose a method for real-time photorealistic stereo rendering of the natural phenomenon of fire. Applications include the use of virtual reality in fire fighting, military training, and entertainment. Rendering fire in real-time presents a challenge because of the transparency and non-static fluid-like behavior of fire. It is well known that, in general, methods that are effective for monoscopic rendering are not necessarily easily extended to stereo rendering because monoscopic methods often do not provide the depth information necessary to produce the parallax required for binocular disparity in stereoscopic rendering. We investigate the existing techniques used for monoscopic rendering of fire and discuss their suitability for extension to real-time stereo rendering. Methods include the use of precomputed textures, dynamic generation of textures, and rendering models resulting from the approximation of solutions of fluid dynamics equations through the use of ray-tracing algorithms. We have found that in order to attain real-time frame rates, our method based on billboarding is effective. Slicing is used to simulate depth. Texture mapping or 2D images are mapped onto polygons and alpha blending is used to treat transparency. We can use video recordings or prerendered high-quality images of fire as textures to attain photorealistic stereo.

  7. Distributed volume rendering and stereoscopic display for radiotherapy treatment planning

    NASA Astrophysics Data System (ADS)

    Hancock, David J.

    in a single view, large regions of the data are rendered very transparently. This is done to ensure that interesting features buried deep within the data are visible from any viewpoint. Rendering images with high degrees of transparency raises a number of problems, primarily the drop in quality of depth cues in the image, but also the increase in computational requirements over surface-based visualisations. One solution to the increase in image generation times is the use of parallel architectures, which are an attractive platform for large visualisation tasks such as this. A parallel implementation of the direct volume rendering algorithm is described and its performance is evaluated. Several issues must be addressed in implementing an interactive rendering system in a distributed computing environment: principally overcoming the latency and limited bandwidth of the typical network connection. This thesis reports a pipelining strategy developed to improve the level of interactivity in such situations. Stereoscopic image presentation offers a method to offset the reduction in clarity of the depth information in the transparent images. The results of an investigation into the effectiveness of stereoscopic display as an aid to perception in highly transparent images are presented. Subjects were shown scenes of a synthetic test data set in which conventional depth cues were very limited. The experiments were designed to discover what effect stereoscopic viewing of the transparent, volume rendered images had on user's depth perception.

  8. Administration of recombinant activated factor VII in the intensive care unit after complex cardiovascular surgery: clinical and economic outcomes.

    PubMed

    Uber, Walter E; Toole, John M; Stroud, Martha R; Haney, Jason S; Lazarchick, John; Crawford, Fred A; Ikonomidis, John S

    2011-06-01

    Refractory bleeding after complex cardiovascular surgery often leads to increased length of stay, cost, morbidity, and mortality. Recombinant activated factor VII administered in the intensive care unit can reduce bleeding, transfusion, and surgical re-exploration. We retrospectively compared factor VII administration in the intensive care unit with reoperation for refractory bleeding after complex cardiovascular surgery. From 1501 patients who underwent cardiovascular procedures between December 2003 and September 2007, 415 high-risk patients were identified. From this cohort, 24 patients were divided into 2 groups based on whether they either received factor VII in the intensive care unit (n = 12) or underwent reoperation (n = 12) for refractory bleeding. Preoperative and postoperative data were collected to compare efficacy, safety, and economic outcomes. In-hospital survival for both groups was 100%. Factor VII was comparable with reoperation in achieving hemostasis, with both groups demonstrating decreases in chest tube output and need for blood products. Freedom from reoperation was achieved in 75% of patients receiving factor VII, whereas reoperation was effective in achieving hemostasis alone in 83.3% of patients. Prothrombin time, international normalized ratio, and median operating room time were significantly less (P < .05) in patients who received factor VII. Both groups had no statistically significant differences in other efficacy, safety, or economic outcomes. Factor VII administration in the intensive care unit appears comparable with reoperation for refractory bleeding after complex cardiovascular surgical procedures and might represent an alternative to reoperation in selected patients. Future prospective, randomized controlled trials might further define its role. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  9. Evaluation of AAV-mediated Gene Therapy for Central Nervous System Disease in Canine Mucopolysaccharidosis VII

    PubMed Central

    Gurda, Brittney L; De Guilhem De Lataillade, Adrien; Bell, Peter; Zhu, Yanqing; Yu, Hongwei; Wang, Ping; Bagel, Jessica; Vite, Charles H; Sikora, Tracey; Hinderer, Christian; Calcedo, Roberto; Yox, Alexander D; Steet, Richard A; Ruane, Therese; O'Donnell, Patricia; Gao, Guangping; Wilson, James M; Casal, Margret; Ponder, Katherine P; Haskins, Mark E

    2016-01-01

    Mucopolysaccharidosis VII (MPS VII) is a lysosomal storage disease arising from mutations in β-d-glucuronidase (GUSB), which results in glycosaminoglycan (GAG) accumulation and a variety of clinical manifestations including neurological disease. Herein, MPS VII dogs were injected intravenously (i.v.) and/or intrathecally (i.t.) via the cisterna magna with AAV9 or AAVrh10 vectors carrying the canine GUSB cDNA. Although i.v. injection alone at 3 days of age resulted in normal cerebrospinal fluid (CSF) GUSB activity, brain tissue homogenates had only ~1 to 6% normal GUSB activity and continued to have elevated GAG storage. In contrast, i.t. injection at 3 weeks of age resulted in CSF GUSB activity 44-fold normal while brain tissue homogenates had >100% normal GUSB activity and reduced GAGs compared with untreated dogs. Markers for secondary storage and inflammation were eliminated in i.t.-treated dogs and reduced in i.v.-treated dogs compared with untreated dogs. Given that i.t.-treated dogs expressed higher levels of GUSB in the CNS tissues compared to those treated i.v., we conclude that i.t. injection of AAV9 or AAVrh10 vectors is more effective than i.v. injection alone in the large animal model of MPS VII. PMID:26447927

  10. Evaluation of AAV-mediated Gene Therapy for Central Nervous System Disease in Canine Mucopolysaccharidosis VII.

    PubMed

    Gurda, Brittney L; De Guilhem De Lataillade, Adrien; Bell, Peter; Zhu, Yanqing; Yu, Hongwei; Wang, Ping; Bagel, Jessica; Vite, Charles H; Sikora, Tracey; Hinderer, Christian; Calcedo, Roberto; Yox, Alexander D; Steet, Richard A; Ruane, Therese; O'Donnell, Patricia; Gao, Guangping; Wilson, James M; Casal, Margret; Ponder, Katherine P; Haskins, Mark E

    2016-02-01

    Mucopolysaccharidosis VII (MPS VII) is a lysosomal storage disease arising from mutations in β-d-glucuronidase (GUSB), which results in glycosaminoglycan (GAG) accumulation and a variety of clinical manifestations including neurological disease. Herein, MPS VII dogs were injected intravenously (i.v.) and/or intrathecally (i.t.) via the cisterna magna with AAV9 or AAVrh10 vectors carrying the canine GUSB cDNA. Although i.v. injection alone at 3 days of age resulted in normal cerebrospinal fluid (CSF) GUSB activity, brain tissue homogenates had only ~1 to 6% normal GUSB activity and continued to have elevated GAG storage. In contrast, i.t. injection at 3 weeks of age resulted in CSF GUSB activity 44-fold normal while brain tissue homogenates had >100% normal GUSB activity and reduced GAGs compared with untreated dogs. Markers for secondary storage and inflammation were eliminated in i.t.-treated dogs and reduced in i.v.-treated dogs compared with untreated dogs. Given that i.t.-treated dogs expressed higher levels of GUSB in the CNS tissues compared to those treated i.v., we conclude that i.t. injection of AAV9 or AAVrh10 vectors is more effective than i.v. injection alone in the large animal model of MPS VII.

  11. Analysis of time series for postal shipments in Regional VII East Java Indonesia

    NASA Astrophysics Data System (ADS)

    Kusrini, DE; Ulama, B. S. S.; Aridinanti, L.

    2018-03-01

    The change of number delivery goods through PT. Pos Regional VII East Java Indonesia indicates that the trend of increasing and decreasing the delivery of documents and non-documents in PT. Pos Regional VII East Java Indonesia is strongly influenced by conditions outside of PT. Pos Regional VII East Java Indonesia so that the prediction the number of document and non-documents requires a model that can accommodate it. Based on the time series plot monthly data fluctuations occur from 2013-2016 then the model is done using ARIMA or seasonal ARIMA and selected the best model based on the smallest AIC value. The results of data analysis about the number of shipments on each product sent through the Sub-Regional Postal Office VII East Java indicates that there are 5 post offices of 26 post offices entering the territory. The largest number of shipments is available on the PPB (Paket Pos Biasa is regular package shipment/non-document ) and SKH (Surat Kilat Khusus is Special Express Mail/document) products. The time series model generated is largely a Random walk model meaning that the number of shipment in the future is influenced by random effects that are difficult to predict. Some are AR and MA models, except for Express shipment products with Malang post office destination which has seasonal ARIMA model on lag 6 and 12. This means that the number of items in the following month is affected by the number of items in the previous 6 months.

  12. What is stereoscopic vision good for?

    NASA Astrophysics Data System (ADS)

    Read, Jenny C. A.

    2015-03-01

    Stereo vision is a resource-intensive process. Nevertheless, it has evolved in many animals including mammals, birds, amphibians and insects. It must therefore convey significant fitness benefits. It is often assumed that the main benefit is improved accuracy of depth judgments, but camouflage breaking may be as important, particularly in predatory animals. In humans, for the last 150 years, stereo vision has been turned to a new use: helping us reproduce visual reality for artistic purposes. By recreating the different views of a scene seen by the two eyes, stereo achieves unprecedented levels of realism. However, it also has some unexpected effects on viewer experience. The disruption of established mechanisms for interpreting pictures may be one reason why some viewers find stereoscopic content disturbing. Stereo vision also has uses in ophthalmology. Clinical stereoacuity tests are used in the management of conditions such as strabismus and amblyopia as well as vision screening. Stereoacuity can reveal the effectiveness of therapy and even predict long-term outcomes post surgery. Yet current clinical stereo tests fall far short of the accuracy and precision achievable in the lab. At Newcastle University, we are exploiting the recent availability of autostereo 3D tablet computers to design a clinical stereotest app in the form of a game suitable for young children. Our goal is to enable quick, accurate and precise stereoacuity measures which will enable clinicians to obtain better outcomes for children with visual disorders.

  13. Evaluation of the Effectiveness of 3D Vascular Stereoscopic Models in Anatomy Instruction for First Year Medical Students

    ERIC Educational Resources Information Center

    Cui, Dongmei; Wilson, Timothy D.; Rockhold, Robin W.; Lehman, Michael N.; Lynch, James C.

    2017-01-01

    The head and neck region is one of the most complex areas featured in the medical gross anatomy curriculum. The effectiveness of using three-dimensional (3D) models to teach anatomy is a topic of much discussion in medical education research. However, the use of 3D stereoscopic models of the head and neck circulation in anatomy education has not…

  14. Effect of Stereoscopic Anaglyphic 3-Dimensional Video Didactics on Learning Neuroanatomy.

    PubMed

    Goodarzi, Amir; Monti, Sara; Lee, Darrin; Girgis, Fady

    2017-11-01

    The teaching of neuroanatomy in medical education has historically been based on didactic instruction, cadaveric dissections, and intraoperative experience for students. Multiple novel 3-dimensional (3D) modalities have recently emerged. Among these, stereoscopic anaglyphic video is easily accessible and affordable, however, its effects have not yet formally been investigated. This study aimed to investigate if 3D stereoscopic anaglyphic video instruction in neuroanatomy could improve learning for content-naive students, as compared with 2-dimensional (2D) video instruction. A single-site controlled prospective case control study was conducted at the School of Education. Content knowledge was assessed at baseline, followed by the presentation of an instructional neuroanatomy video. Participants viewed the video in either 2D or 3D format and then completed a written test of skull base neuroanatomy. Pretest and post-test performances were analyzed with independent Student's t-tests and analysis of covariance. Our study was completed by 249 subjects. At baseline, the 2D (n = 124, F = 97) and 3D groups (n = 125, F = 96) were similar, although the 3D group was older by 1.7 years (P = 0.0355) and the curricula of participating classes differed (P < 0.0001). Average scores for the 3D group were higher for both pretest (2D, M = 19.9%, standard deviation [SD] = 12.5% vs. 3D, M = 23.9%, SD = 14.9%, P = 0.0234) and post-test performances (2D, M = 68.5%, SD = 18.6% vs. 3D, M = 77.3%, SD = 18.8%, P = 0.003), but the magnitude of improvement across groups did not reach statistical significance (2D, M = 48.7%, SD = 21.3%, vs. 3D, M = 53.5%, SD = 22.7%, P = 0.0855). Incorporation of 3D video instruction into curricula without careful integration is insufficient to promote learning over 2D video. Published by Elsevier Inc.

  15. Expanding the versatility of phage display II: improved affinity selection of folded domains on protein VII and IX of the filamentous phage.

    PubMed

    Løset, Geir Åge; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger

    2011-02-24

    Phage display is a leading technology for selection of binders with affinity for specific target molecules. Polypeptides are normally displayed as fusions to the major coat protein VIII (pVIII) or the minor coat protein III (pIII). Whereas pVIII display suffers from drawbacks such as heterogeneity in display levels and polypeptide fusion size limitations, toxicity and infection interference effects have been described for pIII display. Thus, display on other coat proteins such as pVII or pIX might be more attractive. Neither pVII nor pIX display have gained widespread use or been characterized in detail like pIII and pVIII display. Here we present a side-by-side comparison of display on pIII with display on pVII and pIX. Polypeptides of interest (POIs) are fused to pVII or pIX. The N-terminal periplasmic signal sequence, which is required for phage integration of pIII and pVIII and that has been added to pVII and pIX in earlier studies, is omitted altogether. Although the POI display level on pIII is higher than on pVII and pIX, affinity selection with pVII and pIX display libraries is shown to be particularly efficient. Display through pVII and/or pIX represent platforms with characteristics that differ from those of the pIII platform. We have explored this to increase the performance and expand the use of phage display. In the paper, we describe effective affinity selection of folded domains displayed on pVII or pIX. This makes both platforms more attractive alternatives to conventional pIII and pVIII display than they were before.

  16. Expanding the Versatility of Phage Display II: Improved Affinity Selection of Folded Domains on Protein VII and IX of the Filamentous Phage

    PubMed Central

    Løset, Geir Åge; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger

    2011-01-01

    Background Phage display is a leading technology for selection of binders with affinity for specific target molecules. Polypeptides are normally displayed as fusions to the major coat protein VIII (pVIII) or the minor coat protein III (pIII). Whereas pVIII display suffers from drawbacks such as heterogeneity in display levels and polypeptide fusion size limitations, toxicity and infection interference effects have been described for pIII display. Thus, display on other coat proteins such as pVII or pIX might be more attractive. Neither pVII nor pIX display have gained widespread use or been characterized in detail like pIII and pVIII display. Methodology/Principal Findings Here we present a side-by-side comparison of display on pIII with display on pVII and pIX. Polypeptides of interest (POIs) are fused to pVII or pIX. The N-terminal periplasmic signal sequence, which is required for phage integration of pIII and pVIII and that has been added to pVII and pIX in earlier studies, is omitted altogether. Although the POI display level on pIII is higher than on pVII and pIX, affinity selection with pVII and pIX display libraries is shown to be particularly efficient. Conclusions/Significance Display through pVII and/or pIX represent platforms with characteristics that differ from those of the pIII platform. We have explored this to increase the performance and expand the use of phage display. In the paper, we describe effective affinity selection of folded domains displayed on pVII or pIX. This makes both platforms more attractive alternatives to conventional pIII and pVIII display than they were before. PMID:21390283

  17. Achromatized transmission-type holographic screen for a multiview stereoscopic image system

    NASA Astrophysics Data System (ADS)

    Hwang, Seon-Ho; Bobrinev, V. I.; Son, Jung-Young; Shestak, S. A.; Jeon, Hyung-Wook

    1997-09-01

    The main drawback of the use of transmission-type holographic screens is poor color reproduction caused by their high spectral dispersion. For overcoming this drawback, a long, narrow diffusing slit is used as an object when recording the screen. The necessary size and position of the slit relative to the photoplate and to the recording and reconstruction beams are determined by the phase relations of the beams. By use of the slit, holographic screens of 30 cm 40 cm are recorded with a diverging reference beam and are used to display a multiview full-color stereoscopic image. The images displayed on the screen show no sign of color separation except near the edges of the screen. The image brightness on the screen is high enough that it can be watched in a normally illuminated room.

  18. A compact high-definition low-cost digital stereoscopic video camera for rapid robotic surgery development.

    PubMed

    Carlson, Jay; Kowalczuk, Jędrzej; Psota, Eric; Pérez, Lance C

    2012-01-01

    Robotic surgical platforms require vision feedback systems, which often consist of low-resolution, expensive, single-imager analog cameras. These systems are retooled for 3D display by simply doubling the cameras and outboard control units. Here, a fully-integrated digital stereoscopic video camera employing high-definition sensors and a class-compliant USB video interface is presented. This system can be used with low-cost PC hardware and consumer-level 3D displays for tele-medical surgical applications including military medical support, disaster relief, and space exploration.

  19. Molecular analysis of patients with {Beta}-glucuronidase deficiency presenting as hydrops fetalis or as early mucopolysaccharidosis VII

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vervoort, R.; Liebaers, I.; Lissens, W.

    1996-03-01

    Although not all mucopolysaccharidosis type VII (MPS VII) neonates present with hydrops fetalis or with related symptoms, hydrops fetalis is a common form of presentation of this mucopolysaccharidosis. We used reverse-transcription-PCR-SSCP and direct sequencing to screen for mutations in the human {beta}-glucuronidase cDNA of 17 MPS VII patients with severe presentation of the disease. Mutations resulting in an unstable mRNA were detected in genomic DNA with direct sequencing of the PCR-amplified {beta}-glucuronidase exons. We found extensive genetic heterogeneity in MPS VII alleles: in addition to 6 of 12 previously reported mutations (L176F, R216W, R357X, R382C, W507X, and W627C), we detectedmore » 14 undescribed mutations in the {beta}-glucuronidase coding region that produce MPS VII alleles (G136R, E150K, S312X, Y320S, Y320C, H351Y, R382H, R374C, R435P, R477W, G572D, Y508C, K606N, and 1900{Delta}GA). The mutations in hydropic fetuses were widely scattered in the {beta}-glucuronidase gene. Analysis of three polymorphic sites of the mutant alleles (1766T/C, 1972C/T, and a new 1091+27C/G polymorphism) allowed exclusion of identity by descent for some recurrent mutations. Three of four mutations introducing a premature translation stop codon were found to affect mRNA abundance and/or structure. Expression studies provided evidence for the causal relationship between each of the mutations found in MPS VII alleles and the enzyme deficiency, in that all mutations identified exhibited markedly reduced enzyme activity expressed in COS7 cells following transfection with the mutant cDNA. 52 refs., 4 figs., 5 tabs.« less

  20. Molecular analysis of patients with beta-glucuronidase deficiency presenting as hydrops fetalis or as early mucopolysaccharidosis VII.

    PubMed Central

    Vervoort, R.; Islam, M. R.; Sly, W. S.; Zabot, M. T.; Kleijer, W. J.; Chabas, A.; Fensom, A.; Young, E. P.; Liebaers, I.; Lissens, W.

    1996-01-01

    Although not all mucopolysaccharidosis type VII (MPS VII) neonates present with hydrops fetalis or with related symptoms, hydrops fetalis is a common form of presentation of this mucopolysaccharidosis. We used reverse-transcription-PCR-SSCP and direct sequencing to screen for mutations in the human beta-glucuronidase cDNA of 17 MPS VII patients with severe presentation of the disease. Mutations resulting in an unstable mRNA were detected in genomic DNA with direct sequencing of the PCR-amplified beta-glucuronidase exons. We found extensive genetic heterogeneity in MPS VII alleles: in addition to 6 or 12 previously reported mutations (L176F, R216W, R357X, R382C, W507X, and W627C), we detected 14 undescribed mutations in the beta-glucuronidase coding region that produce MPS VII alleles (G136R, E150K, S312X, Y320S, Y320C, H351Y, R382H, R374C, R435P, R477W, G572D, Y508C, K606N and 1900 delta GA). The mutations in hydropic fetuses were widely scattered in the beta-glucuronidase gene. Analysis of three polymorphic sites of the mutant alleles (1766T/C, 1972C/T and a new 1091+27C/G polymorphism) allowed exclusion of identity by descent for some recurrent mutations. Three of four mutations introducing a premature translation stop codon were found to affect mRNA abundance and/or structure. Expression studies provided evidence for the causal relationship between each of the mutations found in MPS VII alleles and the enzyme deficiency, in that all mutations identified exhibited markedly reduced enzyme activity expressed in COS7 cells following transfection with the mutant cDNA. Images Figure 2 Figure 3A Figure 3BC Figure 4 PMID:8644704

  1. Stability of prothrombin and factor VII in freeze-dried plasma

    PubMed Central

    Brozović, M.; Gurd, L. J.; Robertson, I.; Bangham, D. R.

    1971-01-01

    The stability of prothrombin and factor VII was studied using accelerated degradation tests in three preparations of freeze-dried pooled normal plasmas. In a previous report (Brozović, Gurd, Robertson, and Bangham, 1971) factor X was shown to be relatively unstable in these preparations of freeze-dried plasma: it was calculated that up to 8% of the original factor X activity would be lost after 10 years at −20°C, up to 54% at 4°C, and up to 90% at room temperature. The losses of factor VII activity were estimated to be negligible at −20°C, between 2 and 18% at 4°C, and between 20 and 70% of the original activity at 20°C, after 10 years of storage. Prothrombin was found to be less stable than factor VII: the expected loss in 10 years at −20°C may be up to 4%, at 4°C up to 30%, and at 20°C up to 83% of the initial activity. These findings indicate that in freeze-dried plasma prothrombin as well as factor X may be insufficiently stable for plasma to serve as long-term reference material for the standardization of the one-stage prothrombin time. Moreover, the loss of prothrombin and factor X in freeze-dried plasma stored at 4°C may be so high that when it is required to preserve these factors it may be necessary to store freeze-dried plasma at lower temperatures. PMID:5130534

  2. UHECR mass composition measurement at Telescope Array via stereoscopic observation

    NASA Astrophysics Data System (ADS)

    Stroman, Thomas; Telescope Array Collaboration

    2015-04-01

    The masses of primary ultra-high-energy cosmic-ray (UHECR) nuclei cannot be measured directly on an individual basis, but constraints on the chemical composition can be inferred from the distributions of observable properties. The atmospheric slant depth at which a UHECR-induced extensive air shower reaches its maximum number of particles, Xmax, is particularly sensitive to the mass of the incident nucleus, occurring earlier in the shower's longitudinal development for heavier nuclei at a given energy. The Telescope Array in west-central Utah, the northern hemisphere's largest UHECR detector, is equipped for accurate Xmax and energy measurements via stereoscopic fluorescence observation. Using data from seven years of operation, we will present Xmax distributions at several energies E >10 18 . 2eV , and compare them to distributions predicted by detailed detector simulations under an assortment of assumed UHECR compositions and high-energy hadronic interaction models.

  3. Association of ACE and FACTOR VII gene variability with the risk of coronary heart disease in north Indian population.

    PubMed

    Sobti, R C; Maithil, Nishi; Thakur, Hitender; Sharma, Yashpaul; Talwar, K K

    2010-08-01

    The angiotensin converting enzyme (ACE) is a key factor in the production of angiotensin II and in the degradation of bradykinin. Chronic exposure to high levels of circulating and tissue ACE predispose to vascular wall thickening and atherosclerosis. Factor VII (FACTOR VII) is the first enzyme in the extrinsic pathway of the blood coagulation system and plays a key role in hemostasis; it also contributes to the occurrence of thrombotic events. In this study, we have examined the association of ACE and FACTOR VII gene in coronary heart disease patients (n = 300) and their age-matched controls (n = 300). Genotyping was done by PCR-RFLP method. No significant difference was observed in the distribution of I/D genotypes of ACE between cases and controls. In case of FACTOR VII R353Q polymorphism, there was not much difference in the distribution of alleles. AA genotype had protective effect for CHD (OR 0.56, 95% CI 0.37-0.83, P = 0.001). In case of FACTOR VII VNTR, there was difference in the distribution of alleles, H6 (73.5) and H7 (25.5) in cases, and H6 (70.5) and H7 (30.5) in controls. H6H7 and H7H7 genotypes had a protective effect for CHD with OR 0.27, 95% CI 0.18-0.41, P < 0.001, and OR 0.18, 95% CI 0.09-0.36, P < 0.001. Our study showed D allele of ACE to be associated with marginal risk of CHD, AA genotype of FACTOR VII R353Q and H6H7 and H7H7 genotypes of FACTOR VII VNTR showed protective effect for CHD.

  4. Evaluation Design 1977-1978 ESEA Title VII Bilingual Program.

    ERIC Educational Resources Information Center

    Matuszek, Paula; And Others

    A design for the evaluation of ESEA Title VII bilingual programs in the Austin Independent School District is presented. The following topics are included: (1) Evaluation Design Review Form; (2) decision questions including the actual questions addressed on three levels: the Office of Education-Level, the system-level and the project-level; (3) a…

  5. VVER-440 and VVER-1000 reactor dosimetry benchmark - BUGLE-96 versus ALPAN VII.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duo, J. I.

    2011-07-01

    Document available in abstract form only, full text of document follows: Analytical results of the vodo-vodyanoi energetichesky reactor-(VVER-) 440 and VVER-1000 reactor dosimetry benchmarks developed from engineering mockups at the Nuclear Research Inst. Rez LR-0 reactor are discussed. These benchmarks provide accurate determination of radiation field parameters in the vicinity and over the thickness of the reactor pressure vessel. Measurements are compared to calculated results with two sets of tools: TORT discrete ordinates code and BUGLE-96 cross-section library versus the newly Westinghouse-developed RAPTOR-M3G and ALPAN VII.0. The parallel code RAPTOR-M3G enables detailed neutron distributions in energy and space in reducedmore » computational time. ALPAN VII.0 cross-section library is based on ENDF/B-VII.0 and is designed for reactor dosimetry applications. It uses a unique broad group structure to enhance resolution in thermal-neutron-energy range compared to other analogous libraries. The comparison of fast neutron (E > 0.5 MeV) results shows good agreement (within 10%) between BUGLE-96 and ALPAN VII.O libraries. Furthermore, the results compare well with analogous results of participants of the REDOS program (2005). Finally, the analytical results for fast neutrons agree within 15% with the measurements, for most locations in all three mockups. In general, however, the analytical results underestimate the attenuation through the reactor pressure vessel thickness compared to the measurements. (authors)« less

  6. Assessing the precision of gaze following using a stereoscopic 3D virtual reality setting.

    PubMed

    Atabaki, Artin; Marciniak, Karolina; Dicke, Peter W; Thier, Peter

    2015-07-01

    Despite the ecological importance of gaze following, little is known about the underlying neuronal processes, which allow us to extract gaze direction from the geometric features of the eye and head of a conspecific. In order to understand the neuronal mechanisms underlying this ability, a careful description of the capacity and the limitations of gaze following at the behavioral level is needed. Previous studies of gaze following, which relied on naturalistic settings have the disadvantage of allowing only very limited control of potentially relevant visual features guiding gaze following, such as the contrast of iris and sclera, the shape of the eyelids and--in the case of photographs--they lack depth. Hence, in order to get full control of potentially relevant features we decided to study gaze following of human observers guided by the gaze of a human avatar seen stereoscopically. To this end we established a stereoscopic 3D virtual reality setup, in which we tested human subjects' abilities to detect at which target a human avatar was looking at. Following the gaze of the avatar showed all the features of the gaze following of a natural person, namely a substantial degree of precision associated with a consistent pattern of systematic deviations from the target. Poor stereo vision affected performance surprisingly little (only in certain experimental conditions). Only gaze following guided by targets at larger downward eccentricities exhibited a differential effect of the presence or absence of accompanying movements of the avatar's eyelids and eyebrows. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Case report: a 70-year-old man with undiagnosed factor VII deficiency presented with acute ischemic stroke.

    PubMed

    Ip, Hing-Lung; Chan, Anne Yin-Yan; Ng, Kit-Chung; Soo, Yannie Oi-Yan; Wong, Lawrence Ka-Sing

    2013-11-01

    Factor VII deficiency is an uncommon coagulation disorder that patient usually presents with bleeding diathesis, but thrombotic event has been reported. We report a case of unusual clinical presentation in a patient with undiagnosed factor VII deficiency who presented with acute ischemic stroke. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  8. Analysis of scene distortions in stereoscopic images due to the variation of the ideal viewing conditions

    NASA Astrophysics Data System (ADS)

    Viale, Alberto; Villa, Dario

    2011-03-01

    Recently stereoscopy has increased a lot its popularity and various technologies are spreading in theaters and homes allowing observation of stereoscopic images and movies, becoming affordable even for home users. However there are some golden rules that users should follow to ensure a better enjoyment of stereoscopic images, first of all the viewing condition should not be too different from the ideal ones, which were assumed during the production process. To allow the user to perceive stereo depth instead of a flat image, two different views of the same scene are shown to the subject, one is seen just through his left eye and the other just through the right one; the vision process is making the work of merging the two images in a virtual three-dimensional scene, giving to the user the perception of depth. The two images presented to the user were created, either from image synthesis or from more traditional techniques, following the rules of perspective. These rules need some boundary conditions to be explicit, such as eye separation, field of view, parallax distance, viewer position and orientation. In this paper we are interested in studying how the variation of the viewer position and orientation from the ideal ones expressed as specified parameters in the image creation process, is affecting the correctness of the reconstruction of the three-dimensional virtual scene.

  9. 77 FR 64400 - Order of Succession for HUD Region VII

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-19

    ... Urban Development, designates the Order of Succession for the Kansas City Regional Office and its Field... DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT [FR-5550-D-10] Order of Succession for HUD Region VII..., Assistant General Counsel, Administrative Law Division, U.S. Department of Housing and Urban Development...

  10. Evaluation of the International Barrier Corporation's Mark VII median barrier.

    DOT National Transportation Integrated Search

    1992-01-01

    The International Barrier Corporation's (IBC) Mark VII median barrier consists of a steel frame (10 ft long, 42 in high, and 44 in wide at its widest point) filled with sand and covered with a top plate. The barrier has the ability to absorb some of ...

  11. Surgical approaches to complex vascular lesions: the use of virtual reality and stereoscopic analysis as a tool for resident and student education.

    PubMed

    Agarwal, Nitin; Schmitt, Paul J; Sukul, Vishad; Prestigiacomo, Charles J

    2012-08-01

    Virtual reality training for complex tasks has been shown to be of benefit in fields involving highly technical and demanding skill sets. The use of a stereoscopic three-dimensional (3D) virtual reality environment to teach a patient-specific analysis of the microsurgical treatment modalities of a complex basilar aneurysm is presented. Three different surgical approaches were evaluated in a virtual environment and then compared to elucidate the best surgical approach. These approaches were assessed with regard to the line-of-sight, skull base anatomy and visualisation of the relevant anatomy at the level of the basilar artery and surrounding structures. Overall, the stereoscopic 3D virtual reality environment with fusion of multimodality imaging affords an excellent teaching tool for residents and medical students to learn surgical approaches to vascular lesions. Future studies will assess the educational benefits of this modality and develop a series of metrics for student assessments.

  12. Nonredundant functions of Arabidopsis LecRK-V.2 and LecRK-VII.1 in controlling stomatal immunity and jasmonate-mediated stomatal closure.

    PubMed

    Yekondi, Shweta; Liang, Fu-Chun; Okuma, Eiji; Radziejwoski, Amandine; Mai, Hsien-Wei; Swain, Swadhin; Singh, Prashant; Gauthier, Mathieu; Chien, Hsiao-Chiao; Murata, Yoshiyuki; Zimmerli, Laurent

    2018-04-01

    Stomatal immunity restricts bacterial entry to leaves through the recognition of microbe-associated molecular patterns (MAMPs) by pattern-recognition receptors (PRRs) and downstream abscisic acid and salicylic acid signaling. Through a reverse genetics approach, we characterized the function of the L-type lectin receptor kinase-V.2 (LecRK-V.2) and -VII.1 (LecRK-VII.1). Analyses of interactions with the PRR FLAGELLIN SENSING2 (FLS2) were performed by co-immunoprecipitation and bimolecular fluorescence complementation and whole-cell patch-clamp analyses were used to evaluate guard cell Ca 2+ -permeable cation channels. The Arabidopsis thaliana LecRK-V.2 and LecRK-VII.1 and notably their kinase activities were required for full activation of stomatal immunity. Knockout lecrk-V.2 and lecrk-VII.1 mutants were hyper-susceptible to Pseudomonas syringae infection and showed defective stomatal closure in response to bacteria or to the MAMPs flagellin and EF-Tu. By contrast, Arabidopsis over-expressing LecRK-V.2 or LecRK-VII.1 demonstrated a potentiated stomatal immunity. LecRK-V.2 and LecRK-VII.1 are shown to be part of the FLS2 PRR complex. In addition, LecRK-V.2 and LecRK-VII.1 were critical for methyl jasmonate (MeJA)-mediated stomatal closure, notably for MeJA-induced activation of guard cell Ca 2+ -permeable cation channels. This study highlights the role of LecRK-V.2 and LecRK-VII.1 in stomatal immunity at the FLS2 PRR complex and in MeJA-mediated stomatal closure. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  13. The Effect of Neonatal Gene Therapy with a Gamma Retroviral Vector on Cardiac Valve Disease in Mucopolysaccharidosis VII Dogs after a Decade

    PubMed Central

    Bigg, Paul W.; Sleeper, Meg M.; O’Donnell, Patricia A.; Liu, Yuli; Wu, Susan; Casal, Margret L.; Haskins, Mark E.; Ponder, Katherine P.

    2013-01-01

    Mucopolysaccharidosis VII (MPS VII) is due to deficient activity of the lysosomal enzyme β-glucuronidase (GUSB) and results in the accumulation of glycosaminoglycans (GAGs). This study determined the long-term effect of neonatal intravenous injection of a gamma retroviral vector (RV) on cardiac valve disease in MPS VII dogs. Transduced hepatocytes secreted GUSB into blood for up to 11 years at levels similar to or greater than those achieved with enzyme replacement therapy (ERT). Valve regurgitation and thickening were scored from 0 (normal) to +4 (severely abnormal). At 1 year, untreated MPS VII dogs had mitral regurgitation, mitral valve thickening, aortic regurgitation, and aortic valve thickening scores of 2.3±0.7, 2.3±0.6, 1.8±0.5, and 1.6±0.7, respectively, which were higher than the values of 0.6±0.1, 0.1±0.4, 0.3±0.8, and 0.1±0.4, respectively, in treated MPS VII dogs. Treated MPS VII dogs maintained low aortic regurgitation and aortic valve thickening scores for their lifetime. Although mitral regurgitation and mitral valve thickening scores increased to 2.0 at ≥8 years of age in the treated MPS VII dogs, older normal dogs from the colony had similar scores, making it difficult to assess mitral valve disease. Older treated dogs had calcification within the mitral and aortic valve annulus, while GUSB staining demonstrated enzyme activity within the mitral valve. We conclude that neonatal RV-mediated gene therapy reduced cardiac valve disease in MPS VII dogs for up to 11 years, and propose that neonatal initiation of ERT should have a similar effect. PMID:23860311

  14. Measurement of compressed breast thickness by optical stereoscopic photogrammetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyson, Albert H.; Mawdsley, Gordon E.; Yaffe, Martin J.

    2009-02-15

    The determination of volumetric breast density (VBD) from mammograms requires accurate knowledge of the thickness of the compressed breast. In attempting to accurately determine VBD from images obtained on conventional mammography systems, the authors found that the thickness reported by a number of mammography systems in the field varied by as much as 15 mm when compressing the same breast or phantom. In order to evaluate the behavior of mammographic compression systems and to be able to predict the thickness at different locations in the breast on patients, they have developed a method for measuring the local thickness of themore » breast at all points of contact with the compression paddle using optical stereoscopic photogrammetry. On both flat (solid) and compressible phantoms, the measurements were accurate to better than 1 mm with a precision of 0.2 mm. In a pilot study, this method was used to measure thickness on 108 volunteers who were undergoing mammography examination. This measurement tool will allow us to characterize paddle surface deformations, deflections and calibration offsets for mammographic units.« less

  15. Measurement of compressed breast thickness by optical stereoscopic photogrammetry.

    PubMed

    Tyson, Albert H; Mawdsley, Gordon E; Yaffe, Martin J

    2009-02-01

    The determination of volumetric breast density (VBD) from mammograms requires accurate knowledge of the thickness of the compressed breast. In attempting to accurately determine VBD from images obtained on conventional mammography systems, the authors found that the thickness reported by a number of mammography systems in the field varied by as much as 15 mm when compressing the same breast or phantom. In order to evaluate the behavior of mammographic compression systems and to be able to predict the thickness at different locations in the breast on patients, they have developed a method for measuring the local thickness of the breast at all points of contact with the compression paddle using optical stereoscopic photogrammetry. On both flat (solid) and compressible phantoms, the measurements were accurate to better than 1 mm with a precision of 0.2 mm. In a pilot study, this method was used to measure thickness on 108 volunteers who were undergoing mammography examination. This measurement tool will allow us to characterize paddle surface deformations, deflections and calibration offsets for mammographic units.

  16. Telescope Array UHECR composition measurement via stereoscopic fluorescence observation

    NASA Astrophysics Data System (ADS)

    Stroman, Thomas; Bergman, Douglas; Telescope Array Collaboration

    2016-03-01

    When entering Earth's atmosphere at ultra-high energies, cosmic rays (UHECRs) produce extensive air showers whose longitudinal development is influenced by the incident primary particle's mass. Each longitudinal shower profile reaches its maximum particle count at an atmospheric slant depth Xmax, and the distributions of observed Xmax values can be compared to those predicted by detailed simulations of the air-shower physics and the detector; accurately simulated compositions that most closely resemble that found in nature will produce the best agreement between predicted and observed Xmax distributions. This is the basis of composition measurement at the Telescope Array experiment, the largest and most sensitive UHECR detector in the northern hemisphere. At the perimeter of a large surface-detector array are three fluorescence telescope stations, whose overlapping apertures enable high-precision reconstruction of Xmax from stereoscopic observation of air-shower longitudinal profiles. We present the distribution of Xmax observed during eight years of operation, and from comparisons with several simulated combinations of composition and high-energy hadronic physics, we show that a low primary mass is favored at E >10 18 . 2 eV.

  17. Stereoscopic, thermal, and true deep cumulus cloud top heights

    NASA Astrophysics Data System (ADS)

    Llewellyn-Jones, D. T.; Corlett, G. K.; Lawrence, S. P.; Remedios, J. J.; Sherwood, S. C.; Chae, J.; Minnis, P.; McGill, M.

    2004-05-01

    We compare cloud-top height estimates from several sensors: thermal tops from GOES-8 and MODIS, stereoscopic tops from MISR, and directly measured heights from the Goddard Cloud Physics Lidar on board the ER-2, all collected during the CRYSTAL-FACE field campaign. Comparisons reveal a persistent 1-2 km underestimation of cloud-top heights by thermal imagery, even when the finite optical extinctions near cloud top and in thin overlying cirrus are taken into account. The most severe underestimates occur for the tallest clouds. The MISR "best-sinds" and lidar estimates disagree in very similar ways with thermally estimated tops, which we take as evidence of excellent performance by MISR. Encouraged by this, we use MISR to examine variations in cloud penetration and thermal top height errors in several locations of tropical deep convection over multiple seasons. The goals of this are, first, to learn how cloud penetration depends on the near-tropopause environment; and second, to gain further insight into the mysterious underestimation of tops by thermal imagery.

  18. Experimental evidence for competitive growth advantage of genotype VII over VI: implications for foot-and-mouth disease virus serotype A genotype turnover in nature.

    PubMed

    Mohapatra, J K; Subramaniam, S; Singh, N K; Sanyal, A; Pattnaik, B

    2012-04-01

    In India, systematic genotype replacement has been observed for serotype A foot-and-mouth disease virus. After a decade of co-circulation of genotypes VI and VII, genotype VII emerged as the single dominant genotype since 2001. To derive possible explanations for such epochal evolution dynamics, in vitro intergenotype growth competition experiments involving both co- and superinfection regimes were conducted. Coinfection of BHK-21 cells demonstrated abrupt loss in the genotype VI viral load with commensurate increase in the load of genotype VII as measured by the genotype differentiating ELISA, RT-PCR and real-time RT-PCR. The superinfection dynamics was shaped by temporal spacing of infection, where the invading genotype VII took more number of passages than coinfection to eventually overtake the resident genotype VI. It was speculated that such superior replicative fitness of genotype VII could have been a possible factor for the ultimate dominance of genotype VII in nature. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. A virtual reality oriented clinical experiment on post-stroke rehabilitation: performance and preference comparison among different stereoscopic displays­

    NASA Astrophysics Data System (ADS)

    Yeh, Shih-Ching; Rizzo, Albert; Sawchuk, Alexander A.

    2007-02-01

    We have developed a novel VR task: the Dynamic Reaching Test, that measures human forearm movement in 3D space. In this task, three different stereoscopic displays: autostereoscopic (AS), shutter glasses (SG) and head mounted display (HMD), are used in tests in which subjects must catch a virtual ball thrown at them. Parameters such as percentage of successful catches, movement efficiency (subject path length compared to minimal path length), and reaction time are measured to evaluate differences in 3D perception among the three stereoscopic displays. The SG produces the highest percentage of successful catches, though the difference between the three displays is small, implying that users can perform the VR task with any of the displays. The SG and HMD produced the best movement efficiency, while the AS was slightly less efficient. Finally, the AS and HMD produced similar reaction times that were slightly higher (by 0.1 s) than the SG. We conclude that SG and HMD displays were the most effective, but only slightly better than the AS display.

  20. On-demand stereoscopic 3D displays for avionic and military applications

    NASA Astrophysics Data System (ADS)

    Sarma, Kalluri; Lu, Kanghua; Larson, Brent; Schmidt, John; Cupero, Frank

    2010-04-01

    High speed AM LCD flat panels are evaluated for use in Field Sequential Stereoscopic (FSS) 3D displays for military and avionic applications. A 120 Hz AM LCD is used in field-sequential mode for constructing eyewear-based as well as autostereoscopic 3D display demonstrators for test and evaluation. The COTS eyewear-based system uses shutter glasses to control left-eye/right-eye images. The autostereoscopic system uses a custom backlight to generate illuminating pupils for left and right eyes. It is driven in synchronization with the images on the LCD. Both displays provide 3D effect in full-color and full-resolution in the AM LCD flat panel. We have realized luminance greater than 200 fL in 3D mode with the autostereoscopic system for sunlight readability. The characterization results and performance attributes of both systems are described.

  1. Preliminary measurements of kinetic dust temperature using stereoscopic particle image velocimetry

    NASA Astrophysics Data System (ADS)

    Williams, Jeremiah; Thomas, Edward

    2004-11-01

    A dusty (or complex) plasma is a four-component system composed of ions, electrons, neutral particles and charged microparticles. The presence of the microparticle (i.e., dust) component alters the plasma environment, giving rise to a wide variety of new plasma phenomena. Recently, the Auburn Plasma Sciences Laboratory (PSL) has acquired and installed a stereoscopic PIV (stereo-PIV) diagnostic tool for dusty plasma investigations [Thomas, et. al., Phys. Plasmas, 11, L37 (2004)]. This presentation discusses the use of the stereo-PIV technique for determining the velocity space distribution function of the microparticle component of a dc glow discharge dusty plasma. These distribution functions are then used to make preliminary estimates of the kinetic temperature of the dust component. The data is compared to a simple energy balance model that relates the dust temperature to the electric field and neutral pressure.

  2. Remote stereoscopic video play platform for naked eyes based on the Android system

    NASA Astrophysics Data System (ADS)

    Jia, Changxin; Sang, Xinzhu; Liu, Jing; Cheng, Mingsheng

    2014-11-01

    As people's life quality have been improved significantly, the traditional 2D video technology can not meet people's urgent desire for a better video quality, which leads to the rapid development of 3D video technology. Simultaneously people want to watch 3D video in portable devices,. For achieving the above purpose, we set up a remote stereoscopic video play platform. The platform consists of a server and clients. The server is used for transmission of different formats of video and the client is responsible for receiving remote video for the next decoding and pixel restructuring. We utilize and improve Live555 as video transmission server. Live555 is a cross-platform open source project which provides solutions for streaming media such as RTSP protocol and supports transmission of multiple video formats. At the receiving end, we use our laboratory own player. The player for Android, which is with all the basic functions as the ordinary players do and able to play normal 2D video, is the basic structure for redevelopment. Also RTSP is implemented into this structure for telecommunication. In order to achieve stereoscopic display, we need to make pixel rearrangement in this player's decoding part. The decoding part is the local code which JNI interface calls so that we can extract video frames more effectively. The video formats that we process are left and right, up and down and nine grids. In the design and development, a large number of key technologies from Android application development have been employed, including a variety of wireless transmission, pixel restructuring and JNI call. By employing these key technologies, the design plan has been finally completed. After some updates and optimizations, the video player can play remote 3D video well anytime and anywhere and meet people's requirement.

  3. Free energy models for ice VII and liquid water derived from pressure, entropy, and heat capacity relations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myint, Philip C.; Benedict, Lorin X.; Belof, Jonathan L.

    Here, we present equations of state relevant to conditions encountered in ramp and multiple-shock compression experiments of water. These experiments compress water from ambient conditions to pressures as high as about 14 GPa and temperatures of up to several hundreds of Kelvin. Water may freeze into ice VII during this process. Although there are several studies on the thermodynamic properties of ice VII, an accurate and analytic free energy model from which all other properties may be derived in a thermodynamically consistent manner has not been previously determined. We have developed such a free energy model for ice VII thatmore » is calibrated with pressure-volume-temperature measurements and melt curve data. Furthermore, we show that liquid water in the pressure and temperature range of interest is well-represented by a simple Mie-Grüneisen equation of state. Our liquid water and ice VII equations of state are validated by comparing to sound speed and Hugoniot data. Although they are targeted towards ramp and multiple-shock compression experiments, we demonstrate that our equations of state also behave reasonably well at pressures and temperatures that lie somewhat beyond those found in the experiments.« less

  4. Free energy models for ice VII and liquid water derived from pressure, entropy, and heat capacity relations

    DOE PAGES

    Myint, Philip C.; Benedict, Lorin X.; Belof, Jonathan L.

    2017-08-28

    Here, we present equations of state relevant to conditions encountered in ramp and multiple-shock compression experiments of water. These experiments compress water from ambient conditions to pressures as high as about 14 GPa and temperatures of up to several hundreds of Kelvin. Water may freeze into ice VII during this process. Although there are several studies on the thermodynamic properties of ice VII, an accurate and analytic free energy model from which all other properties may be derived in a thermodynamically consistent manner has not been previously determined. We have developed such a free energy model for ice VII thatmore » is calibrated with pressure-volume-temperature measurements and melt curve data. Furthermore, we show that liquid water in the pressure and temperature range of interest is well-represented by a simple Mie-Grüneisen equation of state. Our liquid water and ice VII equations of state are validated by comparing to sound speed and Hugoniot data. Although they are targeted towards ramp and multiple-shock compression experiments, we demonstrate that our equations of state also behave reasonably well at pressures and temperatures that lie somewhat beyond those found in the experiments.« less

  5. Film patterned retarder for stereoscopic three-dimensional display using ink-jet printing method.

    PubMed

    Lim, Young Jin; Yu, Ji Hoon; Song, Ki Hoon; Lee, Myong-Hoon; Ren, Hongwen; Mun, Byung-June; Lee, Gi-Dong; Lee, Seung Hee

    2014-09-22

    We propose a film patterned retarder (FPR) for stereoscopic three-dimensional display with polarization glasses using ink-jet printing method. Conventional FPR process requires coating of photo-alignment and then UV exposure using wire-grid mask, which is very expensive and difficult. The proposed novel fabrication method utilizes a plastic substrate made of polyether sulfone and an alignment layer, poly (4, 4' - (9, 9 -fluorenyl) diphenylene cyclobutanyltetracarboximide) (9FDA/CBDA) in which the former and the latter aligns reactive mesogen along and perpendicular to the rubbing direction, respectively. The ink-jet printing of 9FDA/CBDA line by line allows fabricating the cost effective FPR which can be widely applied for 3D display applications.

  6. Statistics and Title VII Proof: Prima Facie Case and Rebuttal.

    ERIC Educational Resources Information Center

    Whitten, David

    1978-01-01

    The method and means by which statistics can raise a prima facie case of Title VII violation are analyzed. A standard is identified that can be applied to determine whether a statistical disparity is sufficient to shift the burden to the employer to rebut a prima facie case of discrimination. (LBH)

  7. The effect of neonatal gene therapy with a gamma retroviral vector on cardiac valve disease in mucopolysaccharidosis VII dogs after a decade.

    PubMed

    Bigg, Paul W; Sleeper, Meg M; O'Donnell, Patricia A; Liu, Yuli; Wu, Susan; Casal, Margret L; Haskins, Mark E; Ponder, Katherine P

    2013-11-01

    Mucopolysaccharidosis VII (MPS VII) is due to deficient activity of the lysosomal enzyme β-glucuronidase (GUSB) and results in the accumulation of glycosaminoglycans (GAGs). This study determined the long-term effect of neonatal intravenous injection of a gamma retroviral vector (RV) on cardiac valve disease in MPS VII dogs. Transduced hepatocytes secreted GUSB into the blood for up to 11 years at levels similar to or greater than those achieved with enzyme replacement therapy (ERT). Valve regurgitation and thickening were scored from 0 (normal) to +4 (severely abnormal). At 1 year, untreated MPS VII dogs had mitral regurgitation, mitral valve thickening, aortic regurgitation, and aortic valve thickening scores of 2.3 ± 0.7, 2.3 ± 0.6, 1.8 ± 0.5, and 1.6 ± 0.7, respectively, which were higher than the values of 0.6 ± 0.1, 0.1 ± 0.4, 0.3 ± 0.8, and 0.1 ± 0.4, respectively, in treated MPS VII dogs. Treated MPS VII dogs maintained low aortic regurgitation and aortic valve thickening scores in their lifetime. Although mitral regurgitation and mitral valve thickening scores increased to 2.0 at ≥ 8 years of age in the treated MPS VII dogs, older normal dogs from the colony had similar scores, making it difficult to assess mitral valve disease. Older treated dogs had calcification within the mitral and the aortic valve annulus, while GUSB staining demonstrated enzyme activity within the mitral valve. We conclude that neonatal RV-mediated gene therapy reduced cardiac valve disease in MPS VII dogs for up to 11 years, and propose that neonatal initiation of ERT should have a similar effect. © 2013.

  8. Preparing to use vehicle infrastructure integration (VII) in transportation operations : phase II.

    DOT National Transportation Integrated Search

    2009-01-01

    Vehicle infrastructure integration (VII) is an emerging approach intended to create an enabling communication capability to support vehicle-to-vehicle and vehicle-to-infrastructure communications for safety and mobility applications. The Virginia Dep...

  9. Stereoscopic Machine-Vision System Using Projected Circles

    NASA Technical Reports Server (NTRS)

    Mackey, Jeffrey R.

    2010-01-01

    A machine-vision system capable of detecting obstacles large enough to damage or trap a robotic vehicle is undergoing development. The system includes (1) a pattern generator that projects concentric circles of laser light forward onto the terrain, (2) a stereoscopic pair of cameras that are aimed forward to acquire images of the circles, (3) a frame grabber and digitizer for acquiring image data from the cameras, and (4) a single-board computer that processes the data. The system is being developed as a prototype of machine- vision systems to enable robotic vehicles ( rovers ) on remote planets to avoid craters, large rocks, and other terrain features that could capture or damage the vehicles. Potential terrestrial applications of systems like this one could include terrain mapping, collision avoidance, navigation of robotic vehicles, mining, and robotic rescue. This system is based partly on the same principles as those of a prior stereoscopic machine-vision system in which the cameras acquire images of a single stripe of laser light that is swept forward across the terrain. However, this system is designed to afford improvements over some of the undesirable features of the prior system, including the need for a pan-and-tilt mechanism to aim the laser to generate the swept stripe, ambiguities in interpretation of the single-stripe image, the time needed to sweep the stripe across the terrain and process the data from many images acquired during that time, and difficulty of calibration because of the narrowness of the stripe. In this system, the pattern generator does not contain any moving parts and need not be mounted on a pan-and-tilt mechanism: the pattern of concentric circles is projected steadily in the forward direction. The system calibrates itself by use of data acquired during projection of the concentric-circle pattern onto a known target representing flat ground. The calibration- target image data are stored in the computer memory for use as a

  10. Pharmacodynamics of recombinant activated factor VII and plasma-derived factor VII in a cohort of severe FVII deficient patients.

    PubMed

    van Geffen, Mark; Mathijssen, Natascha C J; Holme, Pål A; Laros-van Gorkom, Britta A P; van Kraaij, Marian G J; Masereeuw, Roselinde; Peyvandi, Flora; van Heerde, Waander L

    2013-07-01

    Recombinant activated factor VII (rFVIIa) and plasma-derived factor VII (pdFVII) are used to prevent bleedings in severe FVII deficient patients, despite their short half-lifes. It is suggested that FVII levels of 15-20 IU/dL are sufficient to maintain hemostasis. We analyzed the pharmacodynamic effects of FVII substitution therapy in the Nijmegen Hemostasis Assay (NHA) that simultaneously measures thrombin and plasmin generation. Ten severe FVII deficient patients were treated with 20 μg/kg rFVIIa or 25 IU/kg pdFVII in a cross-over design. Thrombin generation lag-time (TG-LT) was identified as an effect-response parameter. Pharmacodynamic analysis using a maximum effect model showed 50% reduction of the TG-LT effect at ~2 IU/dL FVII activity for both rFVIIa and pdFVII. The FVII activity to obtain TG-LT comparable to the upper limit of normal range in healthy controls (4 min) was given by the effective concentration (ECnormal), showing sufficient hemostasis at 3-4 IU/dL FVII activity. No association was seen between FVII activity and other thrombin or plasmin generation parameters as measured by NHA. In conclusion, 3-4 IU/dL FVII activity seems sufficient to maintain hemostasis in patients with severe FVII deficiency during prophylaxis. These data may suggest a potential value for measurement of TG-LT in the monitoring of FVII(a) therapy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Title VII and the Male/Female Earnings Gap: An Economic Analysis.

    ERIC Educational Resources Information Center

    Beller, Andrea

    1978-01-01

    After controlling statistically for the effects of other factors that affect earnings, it was found that enforcement of sex discrimination charges under Title VII increased the relative demand for women and thus decreased the male/female earnings differential between 1967 and 1974. (Author)

  12. Inhalation Toxicology. VII. Times To Incapacitation and Death for Rats Exposed Continuously to Atmospheric Acrolein Vapor

    DTIC Science & Technology

    1986-05-01

    DOT FMAM-6/5INHALATION TOXICOLOGY : Office of Aviation Medicine VII. Times to Incapacitation and Washington, D.C. 20591 D ahfrR t x oe Continuously to...Accession No. 3. Recipient’s Catalog No. pOT/FAA/AM-86/5 ,4%__ _____ 4. T,tle and Subtoie S. Report Doate INHALATION TOXICOLOGY : VII. TIMES TO...Statement " Combustion toxicology ; smoke; irritant This document is available to the public gas; time-to-incapacitation; time-to- through the National

  13. How much crosstalk can be allowed in a stereoscopic system at various grey levels?

    NASA Astrophysics Data System (ADS)

    Shestak, Sergey; Kim, Daesik; Kim, Yongie

    2012-03-01

    We have calculated a perceptual threshold of stereoscopic crosstalk on the basis of mathematical model of human vision sensitivity. Instead of linear model of just noticeable difference (JND) known as Weber's law we applied nonlinear Barten's model. The predicted crosstalk threshold varies with the background luminance. The calculated values of threshold are in a reasonable agreement with known experimental data. We calculated perceptual threshold of crosstalk for various combinations of the applied grey level. This result can be applied for the assessment of grey-to-grey crosstalk compensation. Further computational analysis of the applied model predicts the increase of the displayable image contrast with reduction of the maximum displayable luminance.

  14. The design and implementation of stereoscopic 3D scalable vector graphics based on WebKit

    NASA Astrophysics Data System (ADS)

    Liu, Zhongxin; Wang, Wenmin; Wang, Ronggang

    2014-03-01

    Scalable Vector Graphics (SVG), which is a language designed based on eXtensible Markup Language (XML), is used to describe basic shapes embedded in webpages, such as circles and rectangles. However, it can only depict 2D shapes. As a consequence, web pages using classical SVG can only display 2D shapes on a screen. With the increasing development of stereoscopic 3D (S3D) technology, binocular 3D devices have been widely used. Under this circumstance, we intend to extend the widely used web rendering engine WebKit to support the description and display of S3D webpages. Therefore, the extension of SVG is of necessity. In this paper, we will describe how to design and implement SVG shapes with stereoscopic 3D mode. Two attributes representing the depth and thickness are added to support S3D shapes. The elimination of hidden lines and hidden surfaces, which is an important process in this project, is described as well. The modification of WebKit is also discussed, which is made to support the generation of both left view and right view at the same time. As is shown in the result, in contrast to the 2D shapes generated by the Google Chrome web browser, the shapes got from our modified browser are in S3D mode. With the feeling of depth and thickness, the shapes seem to be real 3D objects away from the screen, rather than simple curves and lines as before.

  15. Corrective GUSB transfer to the canine mucopolysaccharidosis VII cornea using a helper-dependent canine adenovirus vector

    PubMed Central

    Serratrice, Nicolas; Cubizolle, Aurelie; Ibanes, Sandy; Mestre-Francés, Nadine; Bayo-Puxan, Neus; Creyssels, Sophie; Gennetier, Aurelie; Bernex, Florence; Verdier, Jean-Michel; Haskins, Mark E.; Couderc, Guilhem; Malecaze, Francois; Kalatzis, Vasiliki; Kremer, Eric J.

    2015-01-01

    Corneal transparency is maintained, in part, by specialized fibroblasts called keratocytes, which reside in the fibrous lamellae of the stroma. Corneal clouding, a condition that impairs visual acuity, is associated with numerous diseases, including mucopolysaccharidosis (MPS) type VII. MPS VII is due to deficiency in β-glucuronidase (β-glu) enzymatic activity, which leads to accumulation of glycosaminoglycans (GAGs), and secondary accumulation of gangliosides. Here, we tested the efficacy of canine adenovirus type 2 (CAV-2) vectors to transduce keratocyte in vivo in mice and nonhuman primates, and ex vivo in dog and human corneal explants. Following efficacy studies, we asked if we could treat corneal clouding by the injection a helper-dependent (HD) CAV-2 vector (HD-RIGIE) harboring the human cDNA coding for β-glu (GUSB) in the canine MPS VII cornea. β-Glu activity, GAG content, and lysosome morphology and physiopathology were analyzed. We found that HD-RIGIE injections efficiently transduced coxsackievirus adenovirus receptor-expressing keratocytes in the four species and, compared to mock-injected controls, improved the pathology in the canine MPS VII cornea. The key criterion to corrective therapy was the steady controlled release of β-glu and its diffusion throughout the collagen-dense stroma. These data support the continued evaluation of HD CAV-2 vectors to treat diseases affecting corneal keratocytes. PMID:24607662

  16. ESTABLISHING A STEREOSCOPIC TECHNIQUE FOR DETERMINING THE KINEMATIC PROPERTIES OF SOLAR WIND TRANSIENTS BASED ON A GENERALIZED SELF-SIMILARLY EXPANDING CIRCULAR GEOMETRY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davies, J. A.; Perry, C. H.; Harrison, R. A.

    2013-11-10

    The twin-spacecraft STEREO mission has enabled simultaneous white-light imaging of the solar corona and inner heliosphere from multiple vantage points. This has led to the development of numerous stereoscopic techniques to investigate the three-dimensional structure and kinematics of solar wind transients such as coronal mass ejections (CMEs). Two such methods—triangulation and the tangent to a sphere—can be used to determine time profiles of the propagation direction and radial distance (and thereby radial speed) of a solar wind transient as it travels through the inner heliosphere, based on its time-elongation profile viewed by two observers. These techniques are founded on themore » assumption that the transient can be characterized as a point source (fixed φ, FP, approximation) or a circle attached to Sun-center (harmonic mean, HM, approximation), respectively. These geometries constitute extreme descriptions of solar wind transients, in terms of their cross-sectional extent. Here, we present the stereoscopic expressions necessary to derive propagation direction and radial distance/speed profiles of such transients based on the more generalized self-similar expansion (SSE) geometry, for which the FP and HM geometries form the limiting cases; our implementation of these equations is termed the stereoscopic SSE method. We apply the technique to two Earth-directed CMEs from different phases of the STEREO mission, the well-studied event of 2008 December and a more recent event from 2012 March. The latter CME was fast, with an initial speed exceeding 2000 km s{sup –1}, and highly geoeffective, in stark contrast to the slow and ineffectual 2008 December CME.« less

  17. 29 CFR 1620.27 - Relationship to the Equal Pay Act of title VII of the Civil Rights Act.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Relationship to the Equal Pay Act of title VII of the Civil... OPPORTUNITY COMMISSION THE EQUAL PAY ACT § 1620.27 Relationship to the Equal Pay Act of title VII of the Civil... equal pay under the Equal Pay Act has no relationship to whether the employee is in the lower paying job...

  18. 29 CFR 1605.2 - Reasonable accommodation without undue hardship as required by section 701(j) of title VII of the...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION GUIDELINES ON DISCRIMINATION... address other obligations under title VII not to discriminate on grounds of religion, nor other provisions... to discrimination prohibited by title VII on the bases of race, color, sex, and national origin also...

  19. 29 CFR 1605.2 - Reasonable accommodation without undue hardship as required by section 701(j) of title VII of the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION GUIDELINES ON DISCRIMINATION... address other obligations under title VII not to discriminate on grounds of religion, nor other provisions... to discrimination prohibited by title VII on the bases of race, color, sex, and national origin also...

  20. 29 CFR 1605.2 - Reasonable accommodation without undue hardship as required by section 701(j) of title VII of the...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION GUIDELINES ON DISCRIMINATION... address other obligations under title VII not to discriminate on grounds of religion, nor other provisions... to discrimination prohibited by title VII on the bases of race, color, sex, and national origin also...

  1. 29 CFR 1605.2 - Reasonable accommodation without undue hardship as required by section 701(j) of title VII of the...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION GUIDELINES ON DISCRIMINATION... address other obligations under title VII not to discriminate on grounds of religion, nor other provisions... to discrimination prohibited by title VII on the bases of race, color, sex, and national origin also...

  2. Quantitative proteomics identify an association between extracellular matrix degradation and immunopathology of genotype VII Newcastle disease virus in the spleen in chickens.

    PubMed

    Hu, Zenglei; Gu, Han; Hu, Jiao; Hu, Shunlin; Wang, Xiaoquan; Liu, Xiaowen; Jiao, Xinan; Liu, Xiufan

    2018-06-15

    Pathogenesis of genotype VII Newcastle disease virus (NDV) is characterized with remarkable immunopathology in the spleen in chickens. However, the mechanism for this unique pathological phenotype is not fully understood. Previous transcriptomics data showed that genotype VII NDV JS5/05 caused a greater downregulation of extracellular matrix (ECM) genes than genotype IV virus Herts/33 in the spleen. In this study, the role of ECM in pathology of genotype VII NDV was investigated using quantitative proteomics. Pathology studies showed that JS5/05 caused severe immunopathology characterized with remarkable necrosis in the spleen, whereas Herts/33 only induced mild pathological changes. The ECM was firstly enriched from the spleens and ECM proteins of different categories were identified by LC-MS/MS. Quantitative proteomic analysis showed that JS5/05 caused a significant disruption of ECM integrity and molecular composition compared to Herts/33. Particularly, JS5/05 induced a more remarkable collagen breakdown in the spleen compared to Herts/33. Moreover, matrix metalloproteinase (MMP)-13 and -14 were significantly upregulated by JS5/05 infection. KEGG pathway analysis suggested that differential regulation of ECM proteins by JS5/05 and Herts/33 may impact pathology through different pathways. Therefore, our results suggested that MMP upregulation and consequent ECM degradation contribute to immunopathology of genotype VII NDV in the spleen. Pathogenesis of genotype VII NDV is characterized with severe immunopathology in the spleen in chickens. Elucidating the mechanism of this pathology phenotype is critical to understand pathogenesis of genotype VII NDV. Here, we present the proteomic data of an important non-cellular compartment, the extracellular matrix (ECM), in the spleen from chickens infected with genotype VII and IV NDVs. Our results suggest that significant upregulation of matrix metalloproteinases by genotype VII NDV and consequent disruption of ECM

  3. Bovine adenovirus 3 core protein precursor pVII localizes to mitochondria, and modulates ATP synthesis, mitochondrial Ca2+ and mitochondrial membrane potential.

    PubMed

    Anand, Sanjeev K; Gaba, Amit; Singh, Jaswant; Tikoo, Suresh K

    2014-02-01

    Viruses modulate the functions of mitochondria by translocating viral proteins to the mitochondria. Subcellular fractionation and sensitivity to proteinase K/Triton X-100 treatment of mitochondrial fractions of bovine adenovirus (BAdV)-3-infected/transfected cells suggested that core protein pVII localizes to the mitochondria and contains a functional mitochondrial localization signal. Moreover, mitochondrial localization of BAdV-3 pVII appears to help in the retention of mitochondrial Ca(2+), inducing a significant increase in the levels of ATP and maintaining the mitochondrial membrane potential (MMP) in transfected cells. In contrast, mitochondrial localization of BAdV-3 pVII has no significant effect on the levels of cytoplasmic Ca(2+) and reactive oxygen species production in the transfected cells. Consistent with these results, expression of pVII in transfected cells treated with staurosporine decreased significantly the activation of caspase-3. Our results suggested that BAdV-3 pVII localizes to mitochondria, and interferes with apoptosis by inhibiting loss of the MMP and by increasing mitochondrial Ca(2+) and ATP production.

  4. Large proteoglycan complexes and disturbed collagen architecture in the corneal extracellular matrix of mucopolysaccharidosis type VII (Sly syndrome).

    PubMed

    Young, Robert D; Liskova, Petra; Pinali, Christian; Palka, Barbara P; Palos, Michalis; Jirsova, Katerina; Hrdlickova, Enkela; Tesarova, Marketa; Elleder, Milan; Zeman, Jiri; Meek, Keith M; Knupp, Carlo; Quantock, Andrew J

    2011-08-24

    Deficiencies in enzymes involved in proteoglycan (PG) turnover underlie a number of rare mucopolysaccharidoses (MPS), investigations of which can considerably aid understanding of the roles of PGs in corneal matrix biology. Here, the authors analyze novel pathologic changes in MPS VII (Sly syndrome) to determine the nature of PG-collagen associations in stromal ultrastructure. Transmission electron microscopy and electron tomography were used to investigate PG-collagen architectures and interactions in a cornea obtained at keratoplasty from a 22-year-old man with MPS VII, which was caused by a compound heterozygous mutation in the GUSB gene. Transmission electron microscopy showed atypical morphology of the epithelial basement membrane and Bowman's layer in MPS VII. Keratocytes were packed with cytoplasmic vacuoles containing abnormal glycosaminoglycan (GAG) material, and collagen fibrils were thinner than in normal cornea and varied considerably throughout anterior (14-32 nm), mid (13-42 nm), and posterior (17-39 nm) regions of the MPS VII stroma. PGs viewed in three dimensions were striking in appearance in that they were significantly larger than PGs in normal cornea and formed highly extended linkages with multiple collagen fibrils. Cellular changes in the MPS VII cornea resemble those in other MPS. However, the wide range of collagen fibril diameters throughout the stroma and the extensive matrix presence of supranormal-sized PG structures appear to be unique features of this disorder. The findings suggest that the accumulation of stromal chondroitin-, dermatan-, and heparan-sulfate glycosaminoglycans in the absence of β-glucuronidase-mediated degradation can modulate collagen fibrillogenesis.

  5. Attack of the S. Mutans!: a stereoscopic-3D multiplayer direct-manipulation behavior-modification serious game for improving oral health in pre-teens

    NASA Astrophysics Data System (ADS)

    Hollander, Ari; Rose, Howard; Kollin, Joel; Moss, William

    2011-03-01

    Attack! of the S. Mutans is a multi-player game designed to harness the immersion and appeal possible with wide-fieldof- view stereoscopic 3D to combat the tooth decay epidemic. Tooth decay is one of the leading causes of school absences and costs more than $100B annually in the U.S. In 2008 the authors received a grant from the National Institutes of Health to build a science museum exhibit that included a suite of serious games involving the behaviors and bacteria that cause cavities. The centerpiece is an adventure game where five simultaneous players use modified Wii controllers to battle biofilms and bacteria while immersed in environments generated within a 11-foot stereoscopic WUXGA display. The authors describe the system and interface used in this prototype application and some of the ways they attempted to use the power of immersion and the appeal of S3D revolution to change health attitudes and self-care habits.

  6. The effects of three factor VII polymorphisms on factor VII coagulant levels in healthy Singaporean Chinese, Malay and Indian newborns.

    PubMed

    Quek, S C; Low, P S; Saha, N; Heng, C K

    2006-11-01

    Factor VII (FVII) is an independent risk factor for coronary artery disease. Three polymorphisms of the factor VII gene (F7) were studied in a group of healthy newborns comprising 561 Chinese, 398 Malays and 226 Asian Indians from Singapore. The allele frequencies of 3 polymorphisms (R353Q, Promoter 0/10bp Del/Ins and Intron 7) in the FVII gene were ascertained through genotyping by polymerase chain reaction and restriction digestion of amplified fragments. In Chinese the minor allele frequencies are Q: 0.04, Ins: 0.03, R7: 0.44; Malays, Q: 0.06, Ins: 0.10, R7: 0.41; and Indians, Q: 0.25, Ins: 0.23, R7: 0.43. Strong linkage disequilibrium (Delta > 0.7) is observed between the 0/10 bp and the R353Q sites in all ethnic groups. We conclude that: (i) the prevalence of the minor Q and Ins alleles of the R353Q and 0/10 bp polymorphisms are significantly higher in the Indian newborns than the Chinese and Malays; (ii) the Q allele is significantly associated (p = 0.01) with a lower plasma FVII coagulant level in the Indian and Malay neonates; and this polymorphism explains up to 3.8% of the variance in FVII coagulant levels; (iii) there is no significant difference in allele frequencies of the three polymorphisms between neonates with and without family histories of CAD.

  7. The Economics of Enforcement of Title VII of the Civil Rights Act of 1964. Discussion Papers No. 313-75.

    ERIC Educational Resources Information Center

    Beller, Andrea H.

    The purpose of this paper is to estimate the effects of enforcement of Title VII to determine whether and to what extent it has helped to achieve the elimination of employment discrimination. The model developed in this paper is considered to depart from those of previous Title VII studies in two ways. First, it incorporates the effects of the…

  8. A role for very low-dose recombinant activated factor VII in refractory bleeding after cardiac surgery: Lessons from an observational study.

    PubMed

    Hoffmann, Till; Assmann, Alexander; Dierksen, Angelika; Roussel, Elisabeth; Ullrich, Sebastian; Lichtenberg, Artur; Albert, Alexander; Sixt, Stephan

    2018-04-18

    Although off-label use of recombinant activated factor VII against refractory bleeding is incorporated in current guideline recommendations, safety concerns persist predominantly with respect to thromboembolic complications. We analyzed the safety and efficacy of recombinant activated factor VII at a very low dose in cardiosurgical patients with refractory bleeding. This prospective study includes 1180 cardiosurgical patients at risk of bleeding. Goal-directed substitution was based on real-time laboratory testing and clinical scoring of the bleeding intensity. All patients who fulfilled the criteria for enhanced risk of bleeding (n = 281) were consequently included in the present analysis. Patients in whom refractory bleeding developed despite substitution with specific hemostatic compounds (n = 167) received a single shot of very low-dose recombinant activated factor VII (≤20 μg/kg). Mortality and risk of thromboembolic complications, and freedom from stroke and acute myocardial infarction in particular, were analyzed (vs patients without recombinant activated factor VII) by multivariable logistic and Cox regression analyses, as well as Kaplan-Meier estimates. There was no increase in rates of mortality (30-day mortality 4.2% vs 7.0% with P = .418; follow-up survival 85.6% at 13.0 [interquartile range, 8.4-15.7] months vs 80.7% at 10.2 [interquartile range, 7.2-16.1] months with P = .151), thromboembolic complications (6.6% vs 9.6% with P = .637), renal insufficiency, need for percutaneous coronary intervention, duration of ventilation, duration of hospital stay, or rehospitalization in patients receiving very low-dose recombinant activated factor VII compared with patients not receiving recombinant activated factor VII. Complete hemostasis without any need for further hemostatic treatment was achieved after very low-dose recombinant activated factor VII administration in the majority of patients (up to 88.6% vs 0% with P < .001). The key results

  9. ENDF/B-VII.1 Neutron Cross Section Data Testing with Critical Assembly Benchmarks and Reactor Experiments

    NASA Astrophysics Data System (ADS)

    Kahler, A. C.; MacFarlane, R. E.; Mosteller, R. D.; Kiedrowski, B. C.; Frankle, S. C.; Chadwick, M. B.; McKnight, R. D.; Lell, R. M.; Palmiotti, G.; Hiruta, H.; Herman, M.; Arcilla, R.; Mughabghab, S. F.; Sublet, J. C.; Trkov, A.; Trumbull, T. H.; Dunn, M.

    2011-12-01

    The ENDF/B-VII.1 library is the latest revision to the United States' Evaluated Nuclear Data File (ENDF). The ENDF library is currently in its seventh generation, with ENDF/B-VII.0 being released in 2006. This revision expands upon that library, including the addition of new evaluated files (was 393 neutron files previously, now 423 including replacement of elemental vanadium and zinc evaluations with isotopic evaluations) and extension or updating of many existing neutron data files. Complete details are provided in the companion paper [M. B. Chadwick et al., "ENDF/B-VII.1 Nuclear Data for Science and Technology: Cross Sections, Covariances, Fission Product Yields and Decay Data," Nuclear Data Sheets, 112, 2887 (2011)]. This paper focuses on how accurately application libraries may be expected to perform in criticality calculations with these data. Continuous energy cross section libraries, suitable for use with the MCNP Monte Carlo transport code, have been generated and applied to a suite of nearly one thousand critical benchmark assemblies defined in the International Criticality Safety Benchmark Evaluation Project's International Handbook of Evaluated Criticality Safety Benchmark Experiments. This suite covers uranium and plutonium fuel systems in a variety of forms such as metallic, oxide or solution, and under a variety of spectral conditions, including unmoderated (i.e., bare), metal reflected and water or other light element reflected. Assembly eigenvalues that were accurately predicted with ENDF/B-VII.0 cross sections such as unmoderated and uranium reflected 235U and 239Pu assemblies, HEU solution systems and LEU oxide lattice systems that mimic commercial PWR configurations continue to be accurately calculated with ENDF/B-VII.1 cross sections, and deficiencies in predicted eigenvalues for assemblies containing selected materials, including titanium, manganese, cadmium and tungsten are greatly reduced. Improvements are also confirmed for selected

  10. 8 CFR 233.6 - Aliens entering Guam or the Commonwealth of the Northern Mariana Islands pursuant to Title VII of...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the Northern Mariana Islands pursuant to Title VII of Public Law 110-229, âConsolidated Natural Resources Act of 2008.â 233.6 Section 233.6 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY... of the Northern Mariana Islands pursuant to Title VII of Public Law 110-229, “Consolidated Natural...

  11. 8 CFR 233.6 - Aliens entering Guam or the Commonwealth of the Northern Mariana Islands pursuant to Title VII of...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the Northern Mariana Islands pursuant to Title VII of Public Law 110-229, âConsolidated Natural Resources Act of 2008.â 233.6 Section 233.6 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY... of the Northern Mariana Islands pursuant to Title VII of Public Law 110-229, “Consolidated Natural...

  12. 8 CFR 233.6 - Aliens entering Guam or the Commonwealth of the Northern Mariana Islands pursuant to Title VII of...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... the Northern Mariana Islands pursuant to Title VII of Public Law 110-229, âConsolidated Natural Resources Act of 2008.â 233.6 Section 233.6 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY... of the Northern Mariana Islands pursuant to Title VII of Public Law 110-229, “Consolidated Natural...

  13. 8 CFR 233.6 - Aliens entering Guam or the Commonwealth of the Northern Mariana Islands pursuant to Title VII of...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the Northern Mariana Islands pursuant to Title VII of Public Law 110-229, âConsolidated Natural Resources Act of 2008.â 233.6 Section 233.6 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY... of the Northern Mariana Islands pursuant to Title VII of Public Law 110-229, “Consolidated Natural...

  14. 8 CFR 233.6 - Aliens entering Guam or the Commonwealth of the Northern Mariana Islands pursuant to Title VII of...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the Northern Mariana Islands pursuant to Title VII of Public Law 110-229, âConsolidated Natural Resources Act of 2008.â 233.6 Section 233.6 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY... of the Northern Mariana Islands pursuant to Title VII of Public Law 110-229, “Consolidated Natural...

  15. A Novel GUSB Mutation in Brazilian Terriers with Severe Skeletal Abnormalities Defines the Disease as Mucopolysaccharidosis VII

    PubMed Central

    Hytönen, Marjo K.; Arumilli, Meharji; Lappalainen, Anu K.; Kallio, Heli; Snellman, Marjatta; Sainio, Kirsi; Lohi, Hannes

    2012-01-01

    Hundreds of different human skeletal disorders have been characterized at molecular level and a growing number of resembling dysplasias with orthologous genetic defects are being reported in dogs. This study describes a novel genetic defect in the Brazilian Terrier breed causing a congenital skeletal dysplasia. Affected puppies presented severe skeletal deformities observable within the first month of life. Clinical characterization using radiographic and histological methods identified delayed ossification and spondyloepiphyseal dysplasia. Pedigree analysis suggested an autosomal recessive disorder, and we performed a genome-wide association study to map the disease locus using Illumina’s 22K SNP chip arrays in seven cases and eleven controls. A single association was observed near the centromeric end of chromosome 6 with a genome-wide significance after permutation (pgenome  = 0.033). The affected dogs shared a 13-Mb homozygous region including over 200 genes. A targeted next-generation sequencing of the entire locus revealed a fully segregating missense mutation (c.866C>T) causing a pathogenic p.P289L change in a conserved functional domain of β-glucuronidase (GUSB). The mutation was confirmed in a population of 202 Brazilian terriers (p = 7,71×10−29). GUSB defects cause mucopolysaccharidosis VII (MPS VII) in several species and define the skeletal syndrome in Brazilian Terriers. Our results provide new information about the correlation of the GUSB genotype to phenotype and establish a novel canine model for MPS VII. Currently, MPS VII lacks an efficient treatment and this model could be utilized for the development and validation of therapeutic methods for better treatment of MPS VII patients. Finally, since almost one third of the Brazilian terrier population carries the mutation, breeders will benefit from a genetic test to eradicate the detrimental disease from the breed. PMID:22815736

  16. Delayed presentation of traumatic facial nerve (CN VII) paralysis.

    PubMed

    Napoli, Anthony M; Panagos, Peter

    2005-11-01

    Facial nerve paralysis (Cranial Nerve VII, CN VII) can be a disfiguring disorder with profound impact upon the patient. The etiology of facial nerve paralysis may be congenital, iatrogenic, or result from neoplasm, infection, trauma, or toxic exposure. In the emergency department, the most common cause of unilateral facial paralysis is Bell's palsy, also known as idiopathic facial paralysis (IFP). We report a case of delayed presentation of unilateral facial nerve paralysis 3 days after sustaining a traumatic head injury. Re-evaluation and imaging of this patient revealed a full facial paralysis and temporal bone fracture extending into the facial canal. Because cranial nerve injuries occur in approximately 5-10% of head-injured patients, a good history and physical examination is important to differentiate IFP from another etiology. Newer generation high-resolution computed tomography (CT) scans are commonly demonstrating these fractures. An understanding of this complication, appropriate patient follow-up, and early involvement of the Otolaryngologist is important in management of these patients. The mechanism as well as the timing of facial nerve paralysis will determine the proper evaluation, consultation, and management for the patient. Patients with total or immediate paralysis as well as those with poorly prognostic audiogram results are good candidates for surgical repair.

  17. In vitro effects of recombinant activated factor VII on thrombin generation and coagulation following inhibition of platelet procoagulant activity by prasugrel.

    PubMed

    Mazzeffi, Michael; Szlam, Fania; Jakubowski, Joseph A; Tanaka, Kenichi A; Sugidachi, Atsuhiro; Levy, Jerrold H

    2013-07-01

    Prasugrel is a thienopyridyl P2Y12 antagonist with potent antiplatelet effects. At present, little is known about its effects on thrombin generation or what strategies may emergently reverse its anticoagulant effects. In the current study we evaluated whether recombinant activated factor VII may reverse prasugrel induced effects and increase thrombin generation in an in vitro model. The effect of prasugrel active metabolite, PAM (R-138727), was evaluated on platelet aggregation, thrombin generation, and rotational thromboelastometry parameters using blood from 20 healthy volunteers. Additionally, we evaluated the effects of adenosine diphosphate (ADP) and recombinant activated factor VII on restoring these parameters towards baseline values. PAM reduced maximum platelet aggregation and led to platelet disaggregation. It also decreased peak thrombin, increased lag time, and increased time to peak thrombin. Treatment with recombinant activated factor VII restored all three parameters of thrombin generation towards baseline. ADP decreased lag time and time to peak thrombin, but had no effect on peak thrombin. When recombinant activated factor VII and ADP were combined they had a greater effect on thrombin parameters than either drug alone. PAM also increased thromboelastometric clotting time and clot formation time, but had no effect on maximum clot firmness. Treatment with either recombinant activated factor VII or ADP restored these values towards baseline. Recombinant activated factor VII restores thrombin generation in the presence of PAM. In patients taking prasugrel with life-threatening refractory bleeding it has the potential to be a useful therapeutic approach. Additional clinical studies are needed to validate our findings. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Optometric measurements predict performance but not comfort on a virtual object placement task with a stereoscopic three-dimensional display

    NASA Astrophysics Data System (ADS)

    McIntire, John P.; Wright, Steve T.; Harrington, Lawrence K.; Havig, Paul R.; Watamaniuk, Scott N. J.; Heft, Eric L.

    2014-06-01

    Twelve participants were tested on a simple virtual object precision placement task while viewing a stereoscopic three-dimensional (S3-D) display. Inclusion criteria included uncorrected or best corrected vision of 20/20 or better in each eye and stereopsis of at least 40 arc sec using the Titmus stereotest. Additionally, binocular function was assessed, including measurements of distant and near phoria (horizontal and vertical) and distant and near horizontal fusion ranges using standard optometric clinical techniques. Before each of six 30 min experimental sessions, measurements of phoria and fusion ranges were repeated using a Keystone View Telebinocular and an S3-D display, respectively. All participants completed experimental sessions in which the task required the precision placement of a virtual object in depth at the same location as a target object. Subjective discomfort was assessed using the simulator sickness questionnaire. Individual placement accuracy in S3-D trials was significantly correlated with several of the binocular screening outcomes: viewers with larger convergent fusion ranges (measured at near distance), larger total fusion ranges (convergent plus divergent ranges, measured at near distance), and/or lower (better) stereoscopic acuity thresholds were more accurate on the placement task. No screening measures were predictive of subjective discomfort, perhaps due to the low levels of discomfort induced.

  19. Title VII and Preferential Treatment: Response to EEOC Affirmative Action Guidelines.

    ERIC Educational Resources Information Center

    Schaffrau, Andrew J.

    1979-01-01

    Argues that Title VII prohibits preferential treatment of any group unless ordered by a court pursuant to a judicial finding of unlawful discrimination and unless the preferential treatment is limited to providing relief to judicially identified victims of that discrimination. Available from Georgetown Law Journal, 600 New Jersey Avenue,…

  20. Stereoscopic perception of real depths at large distances.

    PubMed

    Palmisano, Stephen; Gillam, Barbara; Govan, Donovan G; Allison, Robert S; Harris, Julie M

    2010-06-01

    There has been no direct examination of stereoscopic depth perception at very large observation distances and depths. We measured perceptions of depth magnitude at distances where it is frequently reported without evidence that stereopsis is non-functional. We adapted methods pioneered at distances up to 9 m by R. S. Allison, B. J. Gillam, and E. Vecellio (2009) for use in a 381-m-long railway tunnel. Pairs of Light Emitting Diode (LED) targets were presented either in complete darkness or with the environment lit as far as the nearest LED (the observation distance). We found that binocular, but not monocular, estimates of the depth between pairs of LEDs increased with their physical depths up to the maximum depth separation tested (248 m). Binocular estimates of depth were much larger with a lit foreground than in darkness and increased as the observation distance increased from 20 to 40 m, indicating that binocular disparity can be scaled for much larger distances than previously realized. Since these observation distances were well beyond the range of vertical disparity and oculomotor cues, this scaling must rely on perspective cues. We also ran control experiments at smaller distances, which showed that estimates of depth and distance correlate poorly and that our metric estimation method gives similar results to a comparison method under the same conditions.

  1. Heptavalent Actinide Tetroxides NpO 4 – and PuO 4 –: Oxidation of Pu(V) to Pu(VII) by Adding an Electron to PuO 4

    DOE PAGES

    Gibson, John K.; de Jong, Wibe A.; Dau, Phuong D.; ...

    2017-11-14

    The highest known actinide oxidation states are Np(VII) and Pu(VII), both of which have been identified in solution and solid compounds. Recently a molecular Np(VII) complex, NpO 3(NO 3) 2-, was prepared and characterized in the gas phase. In accord with the lower stability of heptavalent Pu, no Pu(VII) molecular species has been identified. Reported here are the gas-phase syntheses and characterizations of NpO 4 - and PuO 4 -. Reactivity studies and density functional theory computations indicate the heptavalent metal oxidation state in both. This is the first instance of Pu(VII) in the absence of stabilizing effects due tomore » condensed phase solvation or crystal fields. Here, the results indicate that addition of an electron to neutral PuO 4, which has a computed electron affinity of 2.56 eV, counterintuitively results in oxidation of Pu(V) to Pu(VII), concomitant with superoxide reduction.« less

  2. Heptavalent Actinide Tetroxides NpO 4 – and PuO 4 –: Oxidation of Pu(V) to Pu(VII) by Adding an Electron to PuO 4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gibson, John K.; de Jong, Wibe A.; Dau, Phuong D.

    The highest known actinide oxidation states are Np(VII) and Pu(VII), both of which have been identified in solution and solid compounds. Recently a molecular Np(VII) complex, NpO 3(NO 3) 2-, was prepared and characterized in the gas phase. In accord with the lower stability of heptavalent Pu, no Pu(VII) molecular species has been identified. Reported here are the gas-phase syntheses and characterizations of NpO 4 - and PuO 4 -. Reactivity studies and density functional theory computations indicate the heptavalent metal oxidation state in both. This is the first instance of Pu(VII) in the absence of stabilizing effects due tomore » condensed phase solvation or crystal fields. Here, the results indicate that addition of an electron to neutral PuO 4, which has a computed electron affinity of 2.56 eV, counterintuitively results in oxidation of Pu(V) to Pu(VII), concomitant with superoxide reduction.« less

  3. R353Q polymorphism in the factor VII gene and cardiovascular risk in Heterozygous Familial Hypercholesterolemia: a case-control study.

    PubMed

    Criado-García, Juan; Fuentes, Francisco; Cruz-Teno, Cristina; García-Rios, Antonio; Jiménez-Morales, Anabel; Delgado-Lista, Javier; Mata, Pedro; Alonso, Rodrigo; López-Miranda, José; Pérez-Jiménez, Francisco

    2011-04-09

    Heterozygous Familial Hypercholesterolemia (FH) is a genetic disorder characterized by a high risk of cardiovascular disease. Certain polymorphisms of the factor VII gene have been associated with the development of coronary artery disease and there is a known association between factor VII levels and polymorphic variants in this gene. To date, no study has evaluated the association between factor VII and coronary artery disease in patients with FH. This case-control study comprised 720 patients (546 with FH and 174 controls). We determined the prevalence and allele frequencies of the R353Q polymorphism of factor VII, the plasma levels of factor VII antigen (FVII Ag) and whether they could be predictive factors for cardiovascular risk. 75% (410) of the patients with FH were RR, 23% (127) RQ and 1.6% (9) QQ; in the control group 75.3% (131) were RR, 21.3% (37) RQ and 3.4% (6) QQ (p = 0.32). No statistically significant associations were observed in the distribution of genotypes and allele frequencies between case (FH) and control groups. Nor did we find differences when we evaluated the relationship between the R353Q polymorphism and cardiovascular risk (including coronary disease, ischemic stroke and peripheral arterial disease), either in the univariate analysis or after adjustment for sex, age, arterial hypertension, body mass index, xanthomas, diabetes, smoking, HDLc and LDLc and lipid-lowering treatment. The FVII Ag concentrations behaved in a similar fashion, with no differences for the interaction between controls and those with FH (RR vs. RQ/QQ; p = 0.96). In the subgroup of patients with FH no association was found among cardiovascular disease, genotype and FVII Ag levels (RR vs. RQ/QQ; p = 0.97). Our study did not find a direct relationship between cardiovascular risk in patients with Heterozygous Familial Hypercholesterolemia, the R353Q polymorphism of factor VII and FVII Ag levels.

  4. Vehicle infrastructure integration (VII) based road-condition warning system for highway collision prevention.

    DOT National Transportation Integrated Search

    2009-05-01

    As a major ITS initiative, the Vehicle Infrastructure Integration (VII) program is to revolutionize : transportation by creating an enabling communication infrastructure that will open up a wide range of : safety applications. The road-condition warn...

  5. Prolonged Prothrombin Time After Recombinant Activated Factor VII Therapy in Critically Bleeding Trauma Patients Is Associated With Adverse Outcomes

    DTIC Science & Technology

    2010-07-01

    using the FVII coagulant activity (FVII:C) assay, a one- stage assay using thromboplastin tissue factor , which quantifies FVII clotting activity in...and the resultant production of dysfunctional factors II, VII, and X. This study focused on PT specifically because this measure examines the TF...ORIGINAL ARTICLE Prolonged Prothrombin Time After Recombinant Activated Factor VII Therapy in Critically Bleeding Trauma Patients Is Associated With

  6. The Chinese Bilingual Pilot Program, ESEA Title VII, 1974: Program Guide.

    ERIC Educational Resources Information Center

    San Francisco Unified School District, CA.

    The 1965 Elementary Secondary Education Act Title VII Chinese Bilingual Pilot Program is a bilingual/bicultural program the purpose of which is to provide for the special educational needs of children who have limited English-speaking ability, who come from environments where the dominant language is one other than English, and who come from…

  7. OATYC Journal, Vol. VII, Nos 1-2, Fall 1981-Spring 1982.

    ERIC Educational Resources Information Center

    Fullen, James, Ed.

    1982-01-01

    "OATYC Journal," which is published by the Ohio Association of Two-Year Colleges, is designed as a forum for the exchange of concepts, methods, and findings relevant to the two-year college classroom. Along with commentaries and letters of reaction from the readership, the two issues of volume VII include the following articles: (1)…

  8. Introducing a Public Stereoscopic 3D High Dynamic Range (SHDR) Video Database

    NASA Astrophysics Data System (ADS)

    Banitalebi-Dehkordi, Amin

    2017-03-01

    High dynamic range (HDR) displays and cameras are paving their ways through the consumer market at a rapid growth rate. Thanks to TV and camera manufacturers, HDR systems are now becoming available commercially to end users. This is taking place only a few years after the blooming of 3D video technologies. MPEG/ITU are also actively working towards the standardization of these technologies. However, preliminary research efforts in these video technologies are hammered by the lack of sufficient experimental data. In this paper, we introduce a Stereoscopic 3D HDR database of videos that is made publicly available to the research community. We explain the procedure taken to capture, calibrate, and post-process the videos. In addition, we provide insights on potential use-cases, challenges, and research opportunities, implied by the combination of higher dynamic range of the HDR aspect, and depth impression of the 3D aspect.

  9. Enhanced Functional Recombinant Factor VII Production by HEK 293 Cells Stably Transfected with VKORC1 where the Gamma-Carboxylase Inhibitor Calumenin is Stably Suppressed by shRNA Transfection

    PubMed Central

    Wajih, Nadeem; Owen, John; Wallin, Reidar

    2008-01-01

    Introduction Recombinant members of the vitamin K-dependent protein family (factors IX and VII and protein C) have become important pharmaceuticals in treatment of bleeding disorders and sepsis. However, because the in vivo γ-carboxylation system in stable cell lines used for transfection has a limited capacity of post translational γ carboxylation, the recovery of fully γ-carboxylated and functional proteins is low. Materials and Methods In this work we have engineered recombinant factor VII producing HEK 293 cells to stably overexpress VKORC1, the reduced vitamin K γ-carboxylase cofactor and in addition stably silenced the γ-carboxylase inhibitory protein calumenin. Results and Conclusions Stable cell lines transfected with only a factor VII cDNA had a 9% production of functional recombinant factor VII. On the other hand, these recombinant factor VII producing cells when engineered to overexpress VKORC1 and having calumenin stably suppressed more than 80% by shRNA expression, produced 68% functional factor VII. The technology presented should be applicable to all vertebrae members of the vitamin K-dependent protein family and should lower the production cost of the clinically used factors VII, IX and protein C. PMID:18177690

  10. Enhanced functional recombinant factor VII production by HEK 293 cells stably transfected with VKORC1 where the gamma-carboxylase inhibitor calumenin is stably suppressed by shRNA transfection.

    PubMed

    Wajih, Nadeem; Owen, John; Wallin, Reidar

    2008-01-01

    Recombinant members of the vitamin K-dependent protein family (factors IX and VII and protein C) have become important pharmaceuticals in treatment of bleeding disorders and sepsis. However, because the in vivo gamma-carboxylation system in stable cell lines used for transfection has a limited capacity of post translational gamma-carboxylation, the recovery of fully gamma-carboxylated and functional proteins is low. In this work we have engineered recombinant factor VII producing HEK 293 cells to stably overexpress VKORC1, the reduced vitamin K gamma-carboxylase cofactor and in addition stably silenced the gamma-carboxylase inhibitory protein calumenin. Stable cell lines transfected with only a factor VII cDNA had a 9% production of functional recombinant factor VII. On the other hand, these recombinant factor VII producing cells when engineered to overexpress VKORC1 and having calumenin stably suppressed more than 80% by shRNA expression, produced 68% functional factor VII. The technology presented should be applicable to all vertebrae members of the vitamin K-dependent protein family and should lower the production cost of the clinically used factors VII, IX and protein C.

  11. Fe(II)- and Sulfide-Facilitated Reduction of 99Tc(VII)O4- in Microbially Reduced Hyporheic Zone Sediments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Ji-Hoon; Zachara, John M.; Fredrickson, Jim K.

    Redox-reactive, biogeochemical phases generated by reductive microbial activity in hyporheic zone sediments from a dynamic groundwater-river interaction zone were evaluated for their ability to reduce soluble pertechnetate [99Tc(VII)O4-] to less soluble Tc(IV). The sediments were bioreduced by indigenous microorganisms that were stimulated by organic substrate addition in synthetic groundwater with or without sulfate. In most treatments, 20 µmol L-1 initial aqueous Tc(VII) was reduced to near or below detection (3.82×10-9 mol L-1) over periods of days to months in suspensions of variable solids concentrations. Native sediments containing significant lithogenic Fe(II) in various phases were, in contrast, unreactive with Tc(VII). Themore » reduction rates in the bioreduced sediments increased with increases in sediment mass, in proportion to weak acid-extractable Fe(II) and sediment-associated sulfide (AVS). The rate of Tc(VII) reduction was first order with respect to both aqueous Tc(VII) concentration and sediment mass, but correlations between specific reductant concentrations and reaction rate were not found. X-ray microprobe measurements revealed a strong correlation between Tc hot spots and Fe-containing mineral particles in the sediment. However, only a portion of Fe-containing particles were Tc-hosts. The Tc-hot spots displayed a chemical signature (by EDXRF) similar to pyroxene. The application of autoradiography and electron microprobe allowed further isolation of Tc-containing particles that were invariably found to be ca 100 µm aggregates of primary mineral material embedded within a fine-grained phyllosilicate matrix. EXAFS spectroscopy revealed that the Tc(IV) within these were a combination of a Tc(IV)O2-like phase and Tc(IV)-Fe surface clusters, with a significant fraction of a TcSx-like phase in sediments incubated with SO42-. AVS was implicated as a more selective reductant at low solids concentration even though its concentration was below

  12. Fe(II)- and sulfide-facilitated reduction of 99Tc(VII)O4- in microbially reduced hyporheic zone sediments

    NASA Astrophysics Data System (ADS)

    Lee, Ji-Hoon; Zachara, John M.; Fredrickson, James K.; Heald, Steve M.; McKinley, James P.; Plymale, Andrew E.; Resch, Charles T.; Moore, Dean A.

    2014-07-01

    Redox-reactive, biogeochemical phases generated by reductive microbial activity in hyporheic zone sediments from a dynamic groundwater-river interaction zone were evaluated for their ability to reduce soluble pertechnetate [99Tc(VII)O4-] to less soluble Tc(IV). The sediments were bioreduced by indigenous microorganisms that were stimulated by organic substrate addition in synthetic groundwater with or without sulfate. In most treatments, 20 μmol L-1 initial aqueous Tc(VII) was reduced to near or below detection (3.82 × 10-9 mol L-1) over periods of days to months in suspensions of variable solids concentrations. Native sediments containing significant lithogenic Fe(II) in various phases were, in contrast, unreactive with Tc(VII). The reduction rates in the bioreduced sediments increased with increases in sediment mass, in proportion to weak acid-extractable Fe(II) and sediment-associated sulfide (AVS). The rate of Tc(VII) reduction was first order with respect to both aqueous Tc(VII) concentration and sediment mass, but correlations between specific reductant concentrations and reaction rate were not found. X-ray microprobe measurements revealed a strong correlation between Tc hot spots and Fe-containing mineral particles in the sediment. However, only a portion of Fe-containing particles were Tc-hosts. The Tc-hot spots displayed a chemical signature (by EDXRF) similar to pyroxene. The application of autoradiography and electron microprobe allowed further isolation of Tc-containing particles that were invariably found to be ca 100 μm aggregates of primary mineral material embedded within a fine-grained phyllosilicate matrix. EXAFS spectroscopy revealed that the Tc(IV) within these were a combination of a Tc(IV)O2-like phase and Tc(IV)-Fe surface clusters, with a significant fraction of a TcSx-like phase in sediments incubated with SO42-. AVS was implicated as a more selective reductant at low solids concentration even though its concentration was below that

  13. Continuous infusion of recombinant activated factor VII for bleeding control after lobectomy in a patient with inherited factor VII deficiency.

    PubMed

    Miyata, Naoko; Isaka, Mitsuhiro; Kojima, Hideaki; Maniwa, Tomohiro; Takahashi, Shoji; Takamiya, Osamu; Ohde, Yasuhisa

    2016-03-01

    Inherited factor VII (FVII) deficiency is a rare recessive inherited coagulation disorder with limited available information, especially in patients undergoing major thoracic surgery. In addition, an optimal management strategy for the disease has not been defined. We herein report a case involving a 61-year-old man with asymptomatic FVII deficiency who underwent a right middle and lower lobectomy to treat lung cancer. To the best of our knowledge, the present report is the first to describe the use of recombinant activated FVII continuous infusion for bleeding control after a major thoracic surgery in a patient with inherited FVII deficiency.

  14. Employment discrimination implications of genetic screening in the workplace under Title VII and the Rehabilitation Act.

    PubMed

    Canter, E F

    1984-01-01

    The emergence of genetic screening techniques will permit employers to exclude hypersusceptible individuals from potentially hazardous workplace environments. The denial of employment opportunities to these individuals, however, may constitute discrimination. This Note analyzes genetic screening cases with respect to currently available remedies contained in Title VII of the Civil Rights Act of 1964 and the Rehabilitation Act of 1973. The Note concludes that Title VII claims may succeed but only in limited circumstances and that Rehabilitation Act claims will encounter numerous obstacles to relief. Additionally, the Note discusses some of the implications of the use of genetic screening in the workplace.

  15. Testing of ENDF71x: A new ACE-formatted neutron data library based on ENDF/B-VII.1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gardiner, S. J.; Conlin, J. L.; Kiedrowski, B. C.

    The ENDF71x library [1] is the most thoroughly tested set of ACE-format data tables ever released by the Nuclear Data Team at Los Alamos National Laboratory (LANL). It is based on ENDF/B-VII. 1, the most recently released set of evaluated nuclear data files produced by the US Cross Section Evaluation Working Group (CSEWG). A variety of techniques were used to test and verify the ENDF7 1x library before its public release. These include the use of automated checking codes written by members of the Nuclear Data Team, visual inspections of key neutron data, MCNP6 calculations designed to test data formore » every included combination of isotope and temperature as comprehensively as possible, and direct comparisons between ENDF71x and previous ACE library releases. Visual inspection of some of the most important neutron data revealed energy balance problems and unphysical discontinuities in the cross sections for some nuclides. Doppler broadening of the total cross sections with increasing temperature was found to be qualitatively correct. Test calculations performed using MCNP prompted two modifications to the MCNP6 source code and also exposed bad secondary neutron yields for {sup 231,233}Pa that are present in both ENDF/B-VII.1 and ENDF/B-VII.0. A comparison of ENDF71x with its predecessor ACE library, ENDF70, showed that dramatic changes have been made in the neutron cross section data for a number of isotopes between ENDF/B-VII.0 and ENDF/B-VII.1. Based on the results of these verification tests and the validation tests performed by Kahler, et al. [2], the ENDF71x library is recommended for use in all Monte Carlo applications. (authors)« less

  16. Re-engineering the stereoscope for the 21st Century

    NASA Astrophysics Data System (ADS)

    Kollin, Joel S.; Hollander, Ari J.

    2007-02-01

    While discussing the current state of stereo head-mounted and 3D projection displays, the authors came to the realization that flat-panel LCD displays offer higher resolution than projection for stereo display at a low (and continually dropping) cost. More specifically, where head-mounted displays of moderate resolution and field-of-view cost tens of thousands of dollars, we can achieve an angular resolution approaching that of the human eye with a field-of-view (FOV) greater than 90° for less than $1500. For many immersive applications head tracking is unnecessary and sometimes even undesirable, and a low cost/high quality wide FOV display may significantly increase the application space for 3D display. After outlining the problem and potential of this solution we describe the initial construction of a simple Wheatstone stereoscope using 24" LCD displays and then show engineering improvements that increase the FOV and usability of the system. The applicability of a high-immersion, high-resolution display for art, entertainment, and simulation is presented along with a content production system that utilizes the capabilities of the system. We then discuss the potential use of the system for VR pain control therapy, treatment of post-traumatic stress disorders and other serious games applications.

  17. 40 CFR Appendix Vii to Part 86 - Standard Bench Cycle (SBC)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... VII to Part 86—Standard Bench Cycle (SBC) 1. The standard bench aging durability procedures [Ref. § 86.1823-08(d)] consist of aging a catalyst-oxygen-sensor system on an aging bench which follows the standard bench cycle (SBC) described in this appendix. 2. The SBC requires use of an aging bench with an...

  18. A Pearson VII distribution function for fast calculation of dechanneling and angular dispersion of beams

    NASA Astrophysics Data System (ADS)

    Shao, Lin; Peng, Luohan

    2009-12-01

    Although multiple scattering theories have been well developed, numerical calculation is complicated and only tabulated values have been available, which has caused inconvenience in practical use. We have found that a Pearson VII distribution function can be used to fit Lugujjo and Mayer's probability curves in describing the dechanneling phenomenon in backscattering analysis, over a wide range of disorder levels. Differentiation of the obtained function gives another function to calculate angular dispersion of the beam in the frameworks by Sigmund and Winterbon. The present work provides an easy calculation of both dechanneling probability and angular dispersion for any arbitrary combination of beam and target having a reduced thickness ⩾0.6, which can be implemented in modeling of channeling spectra. Furthermore, we used a Monte Carlo simulation program to calculate the deflection probability and compared them with previously tabulated data. A good agreement was reached.

  19. Streaming video-based 3D reconstruction method compatible with existing monoscopic and stereoscopic endoscopy systems

    NASA Astrophysics Data System (ADS)

    Bouma, Henri; van der Mark, Wannes; Eendebak, Pieter T.; Landsmeer, Sander H.; van Eekeren, Adam W. M.; ter Haar, Frank B.; Wieringa, F. Pieter; van Basten, Jean-Paul

    2012-06-01

    Compared to open surgery, minimal invasive surgery offers reduced trauma and faster recovery. However, lack of direct view limits space perception. Stereo-endoscopy improves depth perception, but is still restricted to the direct endoscopic field-of-view. We describe a novel technology that reconstructs 3D-panoramas from endoscopic video streams providing a much wider cumulative overview. The method is compatible with any endoscope. We demonstrate that it is possible to generate photorealistic 3D-environments from mono- and stereoscopic endoscopy. The resulting 3D-reconstructions can be directly applied in simulators and e-learning. Extended to real-time processing, the method looks promising for telesurgery or other remote vision-guided tasks.

  20. Sexual Intimacy in Training and Practice: Setting Limits for Counselors, Psychologists and Educators.

    ERIC Educational Resources Information Center

    Yarris, Elizabeth

    The September 1988 newsletter of Commission VII (Counseling and Psychological Services) of the American College Personnel Association contained a survey addressing the issues of sexual intimacy in the training and practice of counselors, psychologists and educators. Approximately 800 surveys were mailed to the commission members. Participation in…