Sample records for proximal tibial fractures

  1. "Clothesline technique" for proximal tibial shaft fracture fixation using conventional intramedullary nail: a simple, useful, and inexpensive technique to prevent fracture malalignment.

    PubMed

    Belangero, William Dias; Santos Pires, Robinson Esteves; Livani, Bruno; Rossi, Felipe Lins; de Andrade, Andre Luis Lugnani

    2018-05-01

    Treatment of proximal tibial shaft fractures is always challenging. Despite the development of modern techniques, the literature still shows high complication rates, especially regarding proximal fragment malalignment. It is well known that knee position in flexion during tibial nailing is responsible for extension and valgus deformities of the proximal fragment. Unlike in tibial shaft fractures, nails do not reduce proximal tibial fractures due to the medullary canal width. This study aims to describe a simple, useful, and inexpensive technique to prevent valgus and extension deformities when treating proximal tibial fractures using conventional nails: the so-called clothesline technique.

  2. Proximal tibial fractures: early experience using polyaxial locking-plate technology.

    PubMed

    Nikolaou, Vassilios S; Tan, Hiang Boon; Haidukewych, George; Kanakaris, Nikolaos; Giannoudis, Peter V

    2011-08-01

    Between 2004 and 2009, 60 patients with proximal tibial fractures were included in this prospective study. All fractures were treated with the polyaxial locked-plate fixation system (DePuy, Warsaw, IN, USA). Clinical and radiographic data, including fracture pattern, changes in alignment, local and systemic complications, hardware failure and fracture union were analysed. The mean follow-up was 14 (12-36) months. According to the Orthopaedic Trauma Association (OTA) classification, there were five 41-A, 28 41-B and 27 41-C fractures. Fractures were treated percutaneously in 30% of cases. Double-plating was used in 11 cases. All but three fractures progressed to union at a mean of 3.2 (2.5-5) months. There was no evidence of varus collapse as a result of polyaxial screw failure. No plate fractured, and no screw cut out was noted. There was one case of lateral joint collapse (>10°) in a patient with open bicondylar plateau fracture. The mean Knee Society Score at the time of final follow-up was 91 points, and the mean functional score was 89 points. The polyaxial locking-plate system provided stable fixation of extra-articular and intra-articular proximal tibial fractures and good functional outcomes with a low complication rate.

  3. Trampoline fracture of the proximal tibial metaphysis in children may not progress into valgus: a report of seven cases and a brief review.

    PubMed

    Kakel, R

    2012-06-01

    Fracture of the proximal tibial metaphysis in children is a rare injury but notorious for carrying the risk of subsequent valgus deformity of the tibia. Trampoline-caused fracture of the proximal tibial metaphysis in children may not progress into valgus. We followed up six children who collectively sustained seven fractures of the proximal tibial metaphysis while trampolining with other heavier and/or older children. Initial and follow-up x-rays were reviewed by an orthopaedic surgeons and two radiologists. None of the patients developed valgus deformity with follow-up. Trampoline is associated with a specific type of injury to the proximal tibia when children are trampolining with other heavier children even without falling off the trampoline. This fracture is linear and complete, often non-displaced. Unlike "other" proximal tibial metaphyseal fractures, trampoline-associated proximal tibial metaphysical fracture in children is not associated with a risk of subsequent valgus deformity. Level 4. case series. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  4. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome.

    PubMed

    Kim, Joon-Woo; Oh, Chang-Wug; Oh, Jong-Keon; Kyung, Hee-Soo; Park, Kyeong-Hyeon; Kim, Hee-June; Jung, Jae-Wook; Jung, Young-Soo

    2017-06-01

    High-energy proximal tibial fractures often accompany compartment syndrome and are usually treated by fasciotomy with external fixation followed by secondary plating. However, the initial soft tissue injury may affect bony union, the fasciotomy incision or external fixator pin sites may lead to postoperative wound infections, and the staged procedure itself may adversely affect lower limb function. We assess the results of staged minimally invasive plate osteosynthesis (MIPO) for proximal tibial fractures with acute compartment syndrome. Twenty-eight patients with proximal tibial fractures accompanied by acute compartment syndrome who underwent staged MIPO and had a minimum of 12 months follow-up were enrolled. According to the AO/OTA classification, 6 were 41-A, 15 were 41-C, 2 were 42-A and 5 were 42-C fractures; this included 6 cases of open fractures. Immediate fasciotomy was performed once compartment syndrome was diagnosed and stabilization of the fracture followed using external fixation. After the soft tissue condition normalized, internal conversion with MIPO was done on an average of 37 days (range, 9-158) after index trauma. At the time of internal conversion, the external fixator pin site grades were 0 in 3 cases, 1 in 12 cases, 2 in 10 cases and 3 in 3 cases, as described by Dahl. Radiographic assessment of bony union and alignment and a functional assessment using the Knee Society Score and American Orthopedic Foot and Ankle Society (AOFAS) score were carried out. Twenty-six cases achieved primary bony union at an average of 18.5 weeks. Two cases of nonunion healed after autogenous bone grafting. The mean Knee Society Score and the AOFAS score were 95 and 95.3 respectively, at last follow-up. Complications included 1 case of osteomyelitis in a patient with a grade IIIC open fracture and 1 case of malunion caused by delayed MIPO due to poor wound conditions. Duration of external fixation and the external fixator pin site grade were not related to the

  5. Biological approach to treatment of intra-articular proximal tibial fractures with double osteosynthesis.

    PubMed

    Singh, Saurabh; Patel, Pankaj R; Joshi, Anil Kumar; Naik, Rajnikant N; Nagaraj, Chethan; Kumar, Sudeep

    2009-02-01

    The treatment of intra-articular proximal tibial fractures is associated with complications, and much conflicting literature exists concerning the treatment of choice. In our study, an attempt has been made to develop an ideal and adequate treatment protocol for these intra-articular fractures. The principle of double osteosynthesis, i.e., lateral minimally invasive plate osteosynthesis (MIPO), was combined with a medial external fixator to treat 22 intra-articular proximal tibial fractures with soft tissue injury with a mean follow-up of 25 months. Superficial pin track infection was observed in one case, and no soft tissue breakdown was noted. Loss of articular reconstruction was reported in one case. Bridging callus was seen at 12 weeks (8 weeks-7 months). The principle of substitution or double osteosynthesis, i.e., lateral MIPO, was combined with a medial external fixator and proved to be a fairly good method of fixation in terms of results and complications.

  6. [Close reduction combined with minimally invasive percutaneous plate osteosynthesis for proximal and distal tibial fractures: a report of 56 patients].

    PubMed

    Liu, Yin-Wen; Kuang, Yong; Gu, Xin-Feng; Zheng, Yu-Xin; Li, Zhi-Qiang; Wei, Xiao-En; Zhang, Ming-Cai; Zhan, Hong-Sheng; Shi, Yin-yu

    2013-03-01

    To evaluate the clinical effects of close reduction combined with minimally invasive percutanous plate osteosynthesis (MIPPO) for proximal and distal tibial fractures. From March 2007 to December 2010, 56 patients with proximal and distal tibial fractures were treated with close reduction combined with MIPPO technique. There were 39 males and 17 females,aged from 22 to 67 years with an average of 41.3 years. Left fracture was in 25 cases and right fracture was in 31 cases; proximal tibial fracture was in 15 cases and distal tibial fractures was in 41 cases; 34 cases caused by fall down and 22 cases caused by road accident. The mean time from injury to operation was 1.7 d. Clinical manifestation included pain, swelling of leg with limitation of activity. According to the standard of Johner-Wruhs, clinical effects were evaluated. The mean operative time was 46 min in 56 patients. All fractures obtained satisfactory reduction and the location of plate was good. Incisions healed with one-stage and no superficial or deep infection was found. All the patients were followed up from 8 to 23 months with an average of 14.2 months. Only one fracture complication with delayed union,and after auto grafting with ilium bone,the fracture got union. Other 55 cases obtained bone healing in 15 to 20 weeks after operation and no internal fixation failure was found. The time of walking was 4-6 months after operation,without limping at 7 months after operation. Both lower extremities were symmetrical and the function of knee and ankle got complete recovery. According to the criteria of Johner-Wruhs score,46 cases obtained excellent results,9 good and 2 fair. Treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can not only preserve soft tissue,simplify operative procedure and decrease wound, but also can obtain rigid internal fixation and guarantee early function exercises of knee and ankle joints. The method has the advantages of less soft tissue

  7. Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures.

    PubMed

    Chen, Fancheng; Huang, Xiaowei; Ya, Yingsun; Ma, Fenfen; Qian, Zhi; Shi, Jifei; Guo, Shuolei; Yu, Baoqing

    2018-01-16

    Proximal tibia fractures are one of the most familiar fractures. Surgical approaches are usually needed for anatomical reduction. However, no single treatment method has been widely established as the standard care. Our present study aims to compare the stress and stability of intramedullary nails (IMN) fixation and double locking plate (DLP) fixation in the treatment of extra-articular proximal tibial fractures. A three-dimensional (3D) finite element model of the extra-articular proximal tibial fracture, whose 2-cm bone gap began 7 cm from the tibial plateau articular surface, was created fixed by different fixation implants. The axial compressive load on an adult knee during single-limb stance was imitated by an axial force of 2500 N with a distribution of 60% to the medial compartment, while the distal end was fixed effectively. The equivalent von Mises stress and displacement of the model was used as the output measures for analysis. The maximal equivalent von Mises stress value of the system in the IMN model was 293.23 MPa, which was higher comparing against that in the DLP fixation model (147.04 MPa). And the mean stress of the model in the IMN model (9.25 MPa) was higher than that of the DLP fixation system in terms of equivalent von Mises stress (EVMS) (P < 0.0001). The maximal value of displacement (sum) in the IMN system was 8.82 mm, which was lower than that in the DLP fixation system (9.48 mm). This study demonstrated that the stability provided by the locking plate fixation system was superior to the intramedullary nails fixation system and served as an alternative fixation for the extra-articular proximal tibial fractures of young patients.

  8. Measurement of bone adjacent to tibial shaft fracture.

    PubMed

    Findlay, S C; Eastell, R; Ingle, B M

    2002-12-01

    Delayed union and non-union are common complications after fracture of the tibial shaft. Response of the surrounding bone as a fracture heals could be monitored using techniques currently used in the study of osteoporosis. The aims of our study were to: (1) evaluate the decrement in bone measurements made close to the fracture using dual-energy X-ray absorptiometry (DXA), quantitative ultrasound (QUS) and peripheral quantitative computed tomography (pQCT); (2) compare values for fractured versus non-fractured leg to determine the duration of decrement in bone measurements; and (3) calculate short-term precision in DXA, QUS and pQCT in order to calculate the ratio of decrement to precision (response ratio, RR) to determine the optimal test for monitoring changes after tibial fracture. The biggest decrement in bone measurements at the ipsilateral limb of 28 patients with tibial shaft fracture was observed at the pQCT tibial trabecular sites (distal = 19%, p<0.0001; proximal 5% = 21%, p<0.001; proximal 10% = 28%, p<0.001) and the ultradistal tibia/fibula measured by DXA (19%, p<0.0001). When comparing Z-scores, the magnitude of decrements at the ipsilateral limb was bigger for variables measured directly at the tibia, both proximal and distal to the fracture. The magnitude of the decrement in ultradistal tibia/fibula BMD decreased as the time since fracture increased ( r = 0.55). When response ratios are considered, pQCT measurements at the distal tibia (RR 6-8) and proximal 5% and 10% trabecular sites (RR 5 and 9 respectively) were found to be the most sensitive to change. Therefore, pQCT of the trabecular regions of either the proximal or distal tibia should prove the most sensitive measurement for monitoring changes in bone adjacent to a tibial shaft fracture.

  9. Proximal Tibial Bone Graft

    MedlinePlus

    ... All Site Content AOFAS / FootCareMD / Treatments Proximal Tibial Bone Graft Page Content What is a bone graft? Bone grafts may be needed for various ... the proximal tibia. What is a proximal tibial bone graft? Proximal tibial bone graft (PTBG) is a ...

  10. Concomitant Posterior Hip Dislocation, Ipsilateral Intertrochanteric- and Proximal Tibial- Fractures with Popliteal Artery Injury: A Challenging Trauma Mélange.

    PubMed

    Chotai, Pranit N; Ebraheim, Nabil A; Hart, Ryan; Wassef, Andrew

    2015-11-05

    Constellation of ipsilateral posterior hip dislocation, intertrochanteric- and proximal tibial fracture with popliteal artery injury is rare. Management of this presentation is challenging. A motor vehicle accident victim presented with these injuries, but without any initial signs of vascular compromise. Popliteal artery injury was diagnosed intra-operatively and repaired. This was followed by external fixation of tibial fracture, open reduction of dislocated hip and internal fixation of intertrochanteric fracture. Patient regained bilateral complete weight bearing and returned to pre-accident activity level. Apt surgical management including early repair of vascular injury in such a trauma mélange allows for a positive postoperative outcome.

  11. Tibial bone fractures occurring after medioproximal tibial bone grafts for oral and maxillofacial reconstruction.

    PubMed

    Kim, Il-Kyu; Cho, Hyun-Young; Pae, Sang-Pill; Jung, Bum-Sang; Cho, Hyun-Woo; Seo, Ji-Hoon

    2013-12-01

    Oral and maxillofacial defects often require bone grafts to restore missing tissues. Well-recognized donor sites include the anterior and posterior iliac crest, rib, and intercalvarial diploic bone. The proximal tibia has also been explored as an alternative donor site. The use of the tibia for bone graft has many benefits, such as procedural ease, adequate volume of cancellous and cortical bone, and minimal complications. Although patients rarely complain of pain, swelling, discomfort, or dysfunction, such as gait disturbance, both patients and surgeons should pay close attention to such after effects due to the possibility of tibial fracture. The purpose of this study is to analyze tibial fractures that occurring after osteotomy for a medioproximal tibial graft. An analysis was intended for patients who underwent medioproximal tibial graft between March 2004 and December 2011 in Inha University Hospital. A total of 105 subjects, 30 females and 75 males, ranged in age from 17 to 78 years. We investigated the age, weight, circumstance, and graft timing in relation to tibial fracture. Tibial fractures occurred in four of 105 patients. There were no significant differences in graft region, shape, or scale between the fractured and non-fractured patients. Patients who undergo tibial grafts must be careful of excessive external force after the operation.

  12. Novel implant for peri-prosthetic proximal tibia fractures.

    PubMed

    Tran, Ton; Chen, Bernard K; Wu, Xinhua; Pun, Chung Lun

    2018-03-01

    Repair of peri-prosthetic proximal tibia fractures is very challenging in patients with a total knee replacement or arthroplasty. The tibial component of the knee implant severely restricts the fixation points of the tibial implant to repair peri-prosthetic fractures. A novel implant has been designed with an extended flange over the anterior of tibial condyle to provide additional points of fixation, overcoming limitations of existing generic locking plates used for proximal tibia fractures. Furthermore, the screws fixed through the extended flange provide additional support to prevent the problem of subsidence of tibial component of knee implant. The design methodology involved extraction of bone data from CT scans into a flexible CAD format, implant design and structural evaluation and optimisation using FEM as well as prototype development and manufacture by selective laser melting 3D printing technology with Ti6Al4 V powder. A prototype tibia implant was developed based on a patient-specific bone structure, which was regenerated from the CT images of patient's tibia. The design is described in detail and being applied to fit up to 80% of patients, for both left and right sides based on the average dimensions and shape of the bone structure from a wide range of CT images. A novel tibial implant has been developed to repair peri-prosthetic proximal tibia fractures which overcomes significant constraints from the tibial component of existing knee implant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. [The randomized controlled trial of influences of T shape approach on the function of knee joint in the treatment of proximal tibial fractures].

    PubMed

    Peng, Wei-xiong; Zhang, Zhi; Liang, Jie-hong

    2008-04-01

    To investigate the clinical value of T shape approach in the treatment of proximal tibial fractures. One handrend and thirteen patients of proximal tibial fractures were randomly divided into two groups. Group A: 62 cases underwent the traditional exposure approach. According to Schatzker classification,the cases of II to VI type was 25, 10, 16, 6, 5 respectively. Group B:51 cases underwent T shape approach ahead of knee joint, the cases of II to VI type was 21, 8, 13, 5, 4 respectively. All data were analyzed by SPSS 10.0 to compare operation time, blood loss, duration of hospitalization, healing time, the time of osseous union and complications after operation. Sixty patients in group A and 50 patients in group B were followed-up from 12 to 24 months. (1) Operation time:group B was longer than A (P < 0.01). (2) Mean blood loss and duration of hospitalization was the same. (3) Clinical healing time:group B was shorter. (4) Mean time of osseous union: 48 group B was shorter. Function of knee: group B was better than group A. (Complication: group B was less than group A. As compared with traditional exposure approach, T shape approach of knee joint had advantages of small scar, fewer complications, faster union of fracture and earlier recovery of joint function. The approach is valuable for the treatment of proximal tibial fractures.

  14. Proximal tibial stress fracture associated with mild osteoarthritis of the knee: case report.

    PubMed

    Curković, Marko; Kovac, Kristina; Curković, Bozidar; Babić-Naglić, Durda; Potocki, Kristina

    2011-03-01

    Stress fractures are considered as multifactorial overuse injuries occurring in 0.3%-0.8% of patients suffering from rheumatic diseases, with rheumatoid arthritis being the most common underlying condition. Stress fractures can be classified according to the condition of the bone affected as: 1) fatigue stress fractures occurring when normal bone is exposed to repeated abnormal stresses; and 2) insufficiency stress fractures that occur when normal stress is applied to bone weakened by an underlying condition. Stress fractures are rarely associated with severe forms of knee osteoarthritis, accompanied with malalignment and obesity. We present a patient with a proximal tibial stress fracture associated with mild knee osteoarthritis without associated malalignment or obesity. Stress fracture should be considered when a patient with osteoarthritis presents with sudden deterioration, severe localized tenderness to palpation and localized swelling or periosteal thickening at the pain site and elevated local temperature. The diagnosis of stress fractures in patients with rheumatic diseases may often be delayed because plain film radiographs may not reveal a stress fracture soon after the symptom onset; moreover, evidence of a fracture may never appear on plain radiographs. Triple phase nuclear bone scans and magnetic resonance imaging are more sensitive in the early clinical course than plain films for initial diagnosis.

  15. Proximal tibial fracture following anterior cruciate ligament reconstruction surgery: a biomechanical analysis of the tibial tunnel as a stress riser.

    PubMed

    Aldebeyan, Wassim; Liddell, Antony; Steffen, Thomas; Beckman, Lorne; Martineau, Paul A

    2017-08-01

    This is the first biomechanical study to examine the potential stress riser effect of the tibial tunnel or tunnels after ACL reconstruction surgery. In keeping with literature, the primary hypothesis tested in this study was that the tibial tunnel acts as a stress riser for fracture propagation. Secondary hypotheses were that the stress riser effect increases with the size of the tunnel (8 vs. 10 mm), the orientation of the tunnel [standard (STT) vs. modified transtibial (MTT)], and with the number of tunnels (1 vs. 2). Tibial tunnels simulating both single bundle hamstring graft (8 mm) and bone-patellar tendon-bone graft (10 mm) either STT or MTT position, as well as tunnels simulating double bundle (DB) ACL reconstruction (7, 6 mm), were drilled in fourth-generation saw bones. These five experimental groups and a control group consisting of native saw bones without tunnels were loaded to failure on a Materials Testing System to simulate tibial plateau fracture. There were no statistically significant differences in peak load to failure between any of the groups, including the control group. The fracture occurred through the tibial tunnel in 100 % of the MTT tunnels (8 and 10 mm) and 80 % of the DB tunnels specimens; however, the fractures never (0 %) occurred through the tibial tunnel of the standard tunnels (8 or 10 mm) (P = 0.032). In the biomechanical model, the tibial tunnel does not appear to be a stress riser for fracture propagation, despite suggestions to the contrary in the literature. Use of a standard, more vertical tunnel decreases the risk of ACL graft compromise in the event of a fracture. This may help to inform surgical decision making on ACL reconstruction technique.

  16. Ipsilateral intact fibula as a predictor of tibial plafond fracture pattern and severity.

    PubMed

    Luk, Pamela C; Charlton, Timothy P; Lee, Jackson; Thordarson, David B

    2013-10-01

    The objective of this study was to determine whether there is a difference in fracture pattern and severity of comminution between tibial plafond fractures with and without associated fibular fractures using computed tomography (CT). We hypothesized that the presence of an intact fibula was predictive of increased tibial plafond fracture severity. This was a case control, radiographic review performed at a single level I university trauma center. Between November 2007 and July 2011, 104 patients with 107 operatively treated tibial pilon fractures and preoperative CT scans were identified: 70 patients with 71 tibial plafond fractures had associated fibular fractures, and 34 patients with 36 tibial plafond fractures had intact fibulas. Four criteria were compared between the 2 groups: AO/OTA classification of distal tibia fractures, Topliss coronal and sagittal fracture pattern classification, plafond region of greatest comminution, and degree of proximal extension of fracture line. The intact fibula group had greater percentages of AO/OTA classification B2 type (5.5 vs 0, P = .046) and B3 type (52.8 vs 28.2, P = .013). Conversely, the percentage of AO/OTA classification C3 type was greater in the fractured fibula group (53.5 vs 30.6, P = .025). Evaluation using the Topliss sagittal and coronal classifications revealed no difference between the 2 groups (P = .226). Central and lateral regions of the plafond were the most common areas of comminution in fractured fibula pilons (32% and 31%, respectively). The lateral region of the plafond was the most common area of comminution in intact fibula pilon fractures (42%). There was no statistically significant difference (P = .71) in degree of proximal extension of fracture line between the 2 groups. Tibial plafond fractures with intact fibulas were more commonly associated with AO/OTA classification B-type patterns, whereas those with fractured fibulas were more commonly associated with C-type patterns. An intact fibula

  17. Treatment of segmental tibial fractures with supercutaneous plating.

    PubMed

    He, Xianfeng; Zhang, Jingwei; Li, Ming; Yu, Yihui; Zhu, Limei

    2014-08-01

    Segmental tibial fractures usually follow a high-energy trauma and are often associated with many complications. The purpose of this report is to describe the authors' results in the treatment of segmental tibial fractures with supercutaneous locking plates used as external fixators. Between January 2009 and March 2012, a total of 20 patients underwent external plating (supercutaneous plating) of the segmental tibial fractures using a less-invasive stabilization system locking plate (Synthes, Paoli, Pennsylvania). Six fractures were closed and 14 were open (6 grade IIIa, 2 grade IIIb, 4 grade II, and 2 grade I, according to the Gustilo classification). When imaging studies confirmed bone union, the plates and screws were removed in the outpatient clinic. Average time of follow-up was 23 months (range, 12-47 months). All fractures achieved union. Median time to union was 19 weeks (range, 12-40 weeks) for the proximal fractures and 22 weeks (range, 12-42 weeks) for the distal fractures. Functional results were excellent in 17 patients and good in 3. Delayed union of the fracture occurred in 2 patients. All patients' radiographs showed normal alignment. No rotational deformities and leg shortening were seen. No incidences of deep infection or implant failures occurred. Minor screw tract infection occurred in 2 patients. A new 1-stage protocol using supercutaneous plating as a definitive fixator for segmental tibial fractures is less invasive, has a lower cost, and has a shorter hospitalization time. Surgeons can achieve good reduction, soft tissue reconstruction, stable fixation, and high union rates using supercutaneous plating. The current patients obtained excellent knee and ankle joint motion and good functional outcomes and had a comfortable clinical course. Copyright 2014, SLACK Incorporated.

  18. Periprosthetic fracture of the proximal tibia after lateral unicompartmental knee arthroplasty.

    PubMed

    Kumar, Arun; Chambers, Iain; Wong, Paul

    2008-06-01

    We report a case of periprosthetic fracture of the proximal tibia after lateral unicompartmental knee arthroplasty following a trivial fall. At the time of surgery, the components were found to be loose; and there was a large uncontained tibial defect with bone loss and communition at the fracture site. The patient was treated by revision total knee arthroplasty and proximal structural tibial allograft, with a satisfactory result at 5-year follow up. Our case illustrates that a bone-conserving unicompartmental knee arthroplasty, if complicated by a periprosthetic fracture, can also present with a difficult surgical problem. Attention to preoperative planning and to availability of structural allograft for such difficult cases is recommended.

  19. Proximal tibial osteotomy. A survivorship analysis.

    PubMed

    Ritter, M A; Fechtman, R A

    1988-01-01

    Proximal tibial osteotomy is generally accepted as a treatment for the patient with unicompartmental arthritis. However, a few reports of the long-term results of this procedure are available in the literature, and none have used the technique known as survivorship analysis. This technique has an advantage over conventional analysis because it does not exclude patients for inadequate follow-up, loss to follow-up, or patient death. In this study, survivorship analysis was applied to 78 proximal tibial osteotomies, performed exclusively by the senior author for the correction of a preoperative varus deformity, and a survival curve was constructed. It was concluded that the reliable longevity of the proximal tibial osteotomy is approximately 6 years.

  20. Incidence and epidemiology of tibial shaft fractures.

    PubMed

    Larsen, Peter; Elsoe, Rasmus; Hansen, Sandra Hope; Graven-Nielsen, Thomas; Laessoe, Uffe; Rasmussen, Sten

    2015-04-01

    The literature lacks recent population-based epidemiology studies of the incidence, trauma mechanism and fracture classification of tibial shaft fractures. The purpose of this study was to provide up-to-date information on the incidence of tibial shaft fractures in a large and complete population and report the distribution of fracture classification, trauma mechanism and patient baseline demographics. Retrospective reviews of clinical and radiological records. A total of 196 patients were treated for 198 tibial shaft fractures in the years 2009 and 2010. The mean age at time of fracture was 38.5 (21.2SD) years. The incidence of tibial shaft fracture was 16.9/100,000/year. Males have the highest incidence of 21.5/100,000/year and present with the highest frequency between the age of 10 and 20, whereas women have a frequency of 12.3/100,000/year and have the highest frequency between the age of 30 and 40. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. The majority of tibial shaft fractures occur during walking, indoor activity and sports. The distribution among genders shows that males present a higher frequency of fractures while participating in sports activities and walking. Women present the highest frequency of fractures while walking and during indoor activities. This study shows an incidence of 16.9/100,000/year for tibial shaft fractures. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Bilateral periprosthetic tibial stress fracture after total knee arthroplasty: A case report.

    PubMed

    Ozdemir, Guzelali; Azboy, Ibrahim; Yilmaz, Baris

    2016-01-01

    Periprosthetic fractures around the knee after total knee arthroplasty can be seen in the femur, tibia and patella. The tibial fractures are rare cases. Our case with bilateral tibial stress fracture developed after total knee arthroplasty (TKA) is the first of its kind in the literature. 75-year-old male patient with bilateral knee osteoarthritis had not benefited from conservative treatment methods previously applied. Left TKA was applied. In the second month postoperatively, periprosthetic tibial fracture was identified and osteosynthesis was implemented with locked tibia proximal plate-screw. Bone union in 12 weeks was observed in his follow-ups. After 15 months of his first operation, TKA was applied to the right knee. Postoperatively in the second month, as in the first operation, periprosthetic tibial fracture was detected. Osteosynthesis with locking plate-screw was applied and union in 12 weeks was observed in his follow-up. He was seen mobilized independently and without support in the last control of the case made in the 24th month after the second operation. The number of TKA applications is expected to increase in the future. The incidence of periprosthetic fractures should also be expected to increase in these cases. Periprosthetic tibial fractures after TKA are rarely seen. The treatment of periprosthetic fractures around the knee after TKA can be difficult. In the case of persistent pain in the upper end of the tibia after the surgery, stress fracture should be considered. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. External fixation of tibial pilon fractures and fracture healing.

    PubMed

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  3. Ground reaction forces and bone parameters in females with tibial stress fracture.

    PubMed

    Bennell, Kim; Crossley, Kay; Jayarajan, Jyotsna; Walton, Elizabeth; Warden, Stuart; Kiss, Z Stephen; Wrigley, Tim

    2004-03-01

    Tibial stress fracture is a common overuse running injury that results from the interplay of repetitive mechanical loading and bone strength. This research project aimed to determine whether female runners with a history of tibial stress fracture (TSF) differ in ground reaction force (GRF) parameters during running, regional bone density, and tibial bone geometry from those who have never sustained a stress fracture (NSF). Thirty-six female running athletes (13 TSF; 23 NSF) ranging in age from 18 to 44 yr were recruited for this cross-sectional study. The groups were well matched for demographic, training, and menstrual parameters. A force platform measured selected GRF parameters (peak and time to peak for vertical impact and active forces, and horizontal braking and propulsive forces) during overground running at 4.0 m.s.(-1). Lumbar spine, proximal femur, and distal tibial bone mineral density were assessed by dual energy x-ray absorptiometry. Tibial bone geometry (cross-sectional dimensions and areas, and second moments of area) was calculated from a computerized tomography scan at the junction of the middle and distal thirds. There were no significant differences between the groups for any of the GRF, bone density, or tibial bone geometric parameters (P > 0.05). Both TSF and NSF subjects had bone density levels that were average or above average compared with a young adult reference range. Factor analysis followed by discriminant function analysis did not find any combinations of variables that differentiated between TSF and NSF groups. These findings do not support a role for GRF, bone density, or tibial bone geometry in the development of tibial stress fractures, suggesting that other risk factors were more important in this cohort of female runners.

  4. Hindfoot Valgus following Interlocking Nail Treatment for Tibial Diaphysis Fractures: Can the Fibula Be Neglected?

    PubMed Central

    Uzun, Metin; Kara, Adnan; Adaş, Müjdat; Karslioğlu, Bülent; Bülbül, Murat; Beksaç, Burak

    2014-01-01

    Purpose. We evaluated whether intramedullary nail fixation for tibial diaphysis fractures with concomitant fibula fractures (except at the distal one-third level) managed conservatively with an associated fibula fracture resulted in ankle deformity and assessed the impact of the ankle deformity on lower extremity function. Methods. Sixty middle one-third tibial shaft fractures with associated fibular fractures, except the distal one-third level, were included in this study. All tibial shaft fractures were anatomically reduced and fixed with interlocking intramedullary nails. Fibular fractures were managed conservatively. Hindfoot alignment was assessed clinically. Tibia and fibular lengths were compared to contralateral measurements using radiographs. Functional results were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Foot and Ankle Disability Index Score (FADI). Results. Anatomic union, defined as equal length in operative and contralateral tibias, was achieved in 60 fractures (100%). Fibular shortening was identified in 42 fractures (68%). Mean fibular shortening was 1.2 cm (range, 0.5–2 cm). Clinical exams showed increased hindfoot valgus in 42 fractures (68%). The mean KOOS was 88.4, and the mean FADI score was 90. Conclusion. Fibular fractures in the middle or proximal one-third may need to be stabilized at the time of tibial intramedullary nail fixation to prevent development of hindfoot valgus due to fibular shortening. PMID:25544899

  5. Fractures of the Tibial Plateau Involve Similar Energies as the Tibial Pilon but Greater Articular Surface Involvement

    PubMed Central

    Dibbern, Kevin; Kempton, Laurence B.; Higgins, Thomas F.; Morshed, Saam; McKinley, Todd O.; Marsh, J. Lawrence; Anderson, Donald D.

    2016-01-01

    Patients with tibial pilon fractures have a higher incidence of post-traumatic osteoarthritis than those with fractures of the tibial plateau. This may indicate that pilon fractures present a greater mechanical insult to the joint than do plateau fractures. We tested the hypothesis that fracture energy and articular fracture edge length, two independent indicators of severity, are higher in pilon than plateau fractures. We also evaluated if clinical fracture classification systems accurately reflect severity. Seventy-five tibial plateau fractures and fifty-two tibial pilon fractures from a multi-institutional study were selected to span the spectrum of severity. Fracture severity measures were calculated using objective CT-based image analysis methods. The ranges of fracture energies measured for tibial plateau and pilon fractures were 3.2 to 33.2 Joules (J) and 3.6 to 32.2 J, respectively, and articular fracture edge lengths were 68.0 to 493.0 mm and 56.1 to 288.6 mm, respectively. There were no differences in the fracture energies between the two fracture types, but plateau fractures had greater articular fracture edge lengths (p<0.001). The clinical fracture classifications generally reflected severity, but there was substantial overlap of fracture severity measures between different classes. Clinical Significance Similar fracture energies with different degrees of articular surface involvement suggest a possible explanation for dissimilar rates of post-traumatic osteoarthritis for fractures of the tibial plateau compared to the tibial pilon. The substantial overlap of severity measures between different fracture classes may well have confounded prior clinical studies relying on fracture classification as a surrogate for severity. PMID:27381653

  6. [Surgical approaches to tibial plateau fractures].

    PubMed

    Krause, Matthias; Müller, Gunnar; Frosch, Karl-Heinz

    2018-06-06

    Intra-articular tibial plateau fractures can present a surgical challenge due to complex injury patterns and compromised soft tissue. The treatment goal is to spare the soft tissue and an anatomical reconstruction of the tibial articular surface. Depending on the course of the fracture, a fracture-specific access strategy is recommended to provide correct positioning of the plate osteosynthesis. While the anterolateral approach is used in the majority of lateral tibial plateau fractures, only one third of the joint surface is visible; however, posterolateral fragments require an individual approach, e. g. posterolateral or posteromedial. If necessary, osteotomy of the femoral epicondyles can improve joint access for reduction control. Injuries to the posterior columns should be anatomically reconstructed and biomechanically correctly addressed via posterior approaches. Bony posterior cruciate ligament tears can be refixed via a minimally invasive posteromedial approach.

  7. Fracture of the proximal tibia after revision total knee arthroplasty with an extensor mechanism allograft.

    PubMed

    Klein, Gregg R; Levine, Harlan B; Sporer, Scott M; Hartzband, Mark A

    2013-02-01

    Extensor mechanism reconstruction with an extensor mechanism allograft (EMA) remains one of the most reliable methods for treating the extensor mechanism deficient total knee arthroplasty. We report 3 patients who were treated with an EMA who sustained a proximal tibial shaft fracture. In all 3 cases, a short tibial component was present that ended close to the level of the distal extent of the bone block. When performing an EMA, it is important to recognize that the tibial bone block creates a stress riser and revision to a long-stemmed tibial component should be strongly considered to bypass this point to minimize the risk of fracture. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Tibial plateau fracture following gracilis-semitendinosus anterior cruciate ligament reconstruction: The tibial tunnel stress-riser.

    PubMed

    Sundaram, R O; Cohen, D; Barton-Hanson, N

    2006-06-01

    Tibial plateau fractures following anterior cruciate ligament (ACL) reconstruction are extremely rare. This is the first reported case of a tibial plateau fracture following four-strand gracilis-semitendinosus autograft ACL reconstruction. The tibial tunnel alone may behave as a stress riser which can significantly reduce bone strength.

  9. 'Trampoline fracture' of the proximal tibia in children: report of 3 cases and review of literature.

    PubMed

    Bruyeer, E; Geusens, E; Catry, F; Vanstraelen, L; Vanhoenacker, F

    2012-01-01

    We present three cases of fracture of the proximal tibia in young children who were jumping on a trampoline. The typical radiological findings and the underlying mechanism of trauma are discussed. The key radiological features are: a transverse hairline fracture of the upper tibia often accompanied by a buckle fracture of the lateral or medial tibial cortex, buckling of the anterior upper tibial cortex and anterior tilting of the epiphyseal plate. New types of injuries related to specific recreational activities are recognized. It is often helpful to associate a typical injury with a particular activity. Trampoline related injuries have increased dramatically over the last years. The most common lesions are fractures and ligamentous injuries, in particular a transverse fracture of the proximal tibia. However the radiological findings can be very subtle and easily overlooked. It is therefore important to be aware of the typical history and radiological findings.

  10. Influence of medial parapatellar nail insertion on alignment in proximal tibia fractures--special consideration of the fracture level.

    PubMed

    Weninger, Patrick; Tschabitscher, Manfred; Traxler, Hannes; Pfafl, Veronika; Hertz, Harald

    2010-04-01

    Although a lateral starting point for tibial nailing is recommended to avoid valgus misalignment, higher rates of intra-articular damage were described compared with a medial parapatellar approach. The aim of this anatomic study was to evaluate the fracture level allowing for a safe medial nail entry point without misalignment or dislocation of fragments. Thirty-two fresh-frozen cadaver lower extremities were used to create 1-cm osteotomies at four different levels (n = 8) from 2 cm to 8 cm below the tibial tuberosity. Nine-millimeter unreamed solid titanium tibial nails (Connex, I.T.S. Spectromed, Lassnitzhohe, Austria) were inserted from a medial parapatellar incision. Misalignment (degree) and dislocation of the distal fragment were measured in the frontal and sagittal plane. A medial parapatellar approach for tibial nail insertion mainly caused valgus and anterior bow misalignment and ventral and medial fragment displacement. Mean misalignment and fragment displacement did not exceed 0.5 degree if the osteotomy was performed 8 cm to 9 cm below the tibial tuberosity. According to the results of this study, a medial parapatellar approach can be performed without misalignment and fragment dislocation in proximal tibia fractures extending 8 cm or more below the tibial tuberosity.

  11. Models of tibial fracture healing in normal and Nf1-deficient mice.

    PubMed

    Schindeler, Aaron; Morse, Alyson; Harry, Lorraine; Godfrey, Craig; Mikulec, Kathy; McDonald, Michelle; Gasser, Jürg A; Little, David G

    2008-08-01

    Delayed union and nonunion are common complications associated with tibial fractures, particularly in the distal tibia. Existing mouse tibial fracture models are typically closed and middiaphyseal, and thus poorly recapitulate the prevailing conditions following surgery on a human open distal tibial fracture. This report describes our development of two open tibial fracture models in the mouse, where the bone is broken either in the tibial midshaft (mid-diaphysis) or in the distal tibia. Fractures in the distal tibial model showed delayed repair compared to fractures in the tibial midshaft. These tibial fracture models were applied to both wild-type and Nf1-deficient (Nf1+/-) mice. Bone repair has been reported to be exceptionally problematic in human NF1 patients, and these patients can also spontaneously develop tibial nonunions (known as congenital pseudarthrosis of the tibia), which are recalcitrant to even vigorous intervention. pQCT analysis confirmed no fundamental differences in cortical or cancellous bone in Nf1-deficient mouse tibiae compared to wild-type mice. Although no difference in bone healing was seen in the tibial midshaft fracture model, the healing of distal tibial fractures was found to be impaired in Nf1+/- mice. The histological features associated with nonunited Nf1+/- fractures were variable, but included delayed cartilage removal, disproportionate fibrous invasion, insufficient new bone anabolism, and excessive catabolism. These findings imply that the pathology of tibial pseudarthrosis in human NF1 is complex and likely to be multifactorial.

  12. Tibial shaft fractures in football players

    PubMed Central

    Chang, Winston R; Kapasi, Zain; Daisley, Susan; Leach, William J

    2007-01-01

    Background Football is officially the most popular sport in the world. In the UK, 10% of the adult population play football at least once a year. Despite this, there are few papers in the literature on tibial diaphyseal fractures in this sporting group. In addition, conflicting views on the nature of this injury exist. The purpose of this paper is to compare our experience of tibial shaft football fractures with the little available literature and identify any similarities and differences. Methods and Results A retrospective study of all tibial football fractures that presented to a teaching hospital was undertaken over a 5 year period from 1997 to 2001. There were 244 tibial fractures treated. 24 (9.8%) of these were football related. All patients were male with a mean age of 23 years (range 15 to 29) and shin guards were worn in 95.8% of cases. 11/24 (45.8%) were treated conservatively, 11/24 (45.8%) by Grosse Kemp intramedullary nail and 2/24 (8.3%) with plating. A difference in union times was noted, conservative 19 weeks compared to operative group 23.9 weeks (p < 0.05). Return to activity was also different in the two groups, conservative 27.6 weeks versus operative 23.3 weeks (p < 0.05). The most common fracture pattern was AO Type 42A3 in 14/24 (58.3%). A high number 19/24 (79.2%) were simple transverse or short oblique fractures. There was a low non-union rate 1/24 (4.2%) and absence of any open injury in our series. Conclusion Our series compared similarly with the few reports available in the literature. However, a striking finding noted by the authors was a drop in the incidence of tibial shaft football fractures. It is likely that this is a reflection of recent compulsory FIFA regulations on shinguards as well as improvements in the design over the past decade since its introduction. PMID:17567522

  13. Medial tibial plateau morphology and stress fracture location: A magnetic resonance imaging study.

    PubMed

    Yukata, Kiminori; Yamanaka, Issei; Ueda, Yuzuru; Nakai, Sho; Ogasa, Hiroyoshi; Oishi, Yosuke; Hamawaki, Jun-Ichi

    2017-06-18

    To determine the location of medial tibial plateau stress fractures and its relationship with tibial plateau morphology using magnetic resonance imaging (MRI). A retrospective review of patients with a diagnosis of stress fracture of the medial tibial plateau was performed for a 5-year period. Fourteen patients [three female and 11 male, with an average age of 36.4 years (range, 15-50 years)], who underwent knee MRI, were included. The appearance of the tibial plateau stress fracture and the geometry of the tibial plateau were reviewed and measured on MRI. Thirteen of 14 stress fractures were linear, and one of them stellated on MRI images. The location of fractures was classified into three types. Three fractures were located anteromedially (AM type), six posteromedially (PM type), and five posteriorly (P type) at the medial tibial plateau. In addition, tibial posterior slope at the medial tibial plateau tended to be larger when the fracture was located more posteriorly on MRI. We found that MRI showed three different localizations of medial tibial plateau stress fractures, which were associated with tibial posterior slope at the medial tibial plateau.

  14. Medial tibial plateau morphology and stress fracture location: A magnetic resonance imaging study

    PubMed Central

    Yukata, Kiminori; Yamanaka, Issei; Ueda, Yuzuru; Nakai, Sho; Ogasa, Hiroyoshi; Oishi, Yosuke; Hamawaki, Jun-ichi

    2017-01-01

    AIM To determine the location of medial tibial plateau stress fractures and its relationship with tibial plateau morphology using magnetic resonance imaging (MRI). METHODS A retrospective review of patients with a diagnosis of stress fracture of the medial tibial plateau was performed for a 5-year period. Fourteen patients [three female and 11 male, with an average age of 36.4 years (range, 15-50 years)], who underwent knee MRI, were included. The appearance of the tibial plateau stress fracture and the geometry of the tibial plateau were reviewed and measured on MRI. RESULTS Thirteen of 14 stress fractures were linear, and one of them stellated on MRI images. The location of fractures was classified into three types. Three fractures were located anteromedially (AM type), six posteromedially (PM type), and five posteriorly (P type) at the medial tibial plateau. In addition, tibial posterior slope at the medial tibial plateau tended to be larger when the fracture was located more posteriorly on MRI. CONCLUSION We found that MRI showed three different localizations of medial tibial plateau stress fractures, which were associated with tibial posterior slope at the medial tibial plateau. PMID:28660141

  15. Pathomorphism of spiral tibial fractures in computed tomography imaging.

    PubMed

    Guzik, Grzegorz

    2011-01-01

    Spiral fractures of the tibia are virtually homogeneous with regard to their pathomorphism. The differences that are seen concern the level of fracture of the fibula, and, to a lesser extent, the level of fracture of the tibia, the length of fracture cleft, and limb shortening following the trauma. While conventional radiographs provide sufficient information about the pathomorphism of fractures, computed tomography can be useful in demonstrating the spatial arrangement of bone fragments and topography of soft tissues surrounding the fracture site. Multiple cross-sectional computed tomography views of spiral fractures of the tibia show the details of the alignment of bone chips at the fracture site, axis of the tibial fracture cleft, and topography of soft tissues that are not visible on standard radiographs. A model of a spiral tibial fracture reveals periosteal stretching with increasing spiral and longitudinal displacement. The cleft in tibial fractures has a spiral shape and its line is invariable. Every spiral fracture of both crural bones results in extensive damage to the periosteum and may damage bellies of the long flexor muscle of toes, flexor hallucis longus as well as the posterior tibial muscle. Computed tomography images of spiral fractures of the tibia show details of damage that are otherwise invisible on standard radiographs. Moreover, CT images provide useful information about the spatial location of the bone chips as well as possible threats to soft tissues that surround the fracture site. Every spiral fracture of the tibia is associated with disruption of the periosteum. 1. Computed tomography images of spiral fractures of the tibia show details of damage otherwise invisible on standard radiographs, 2. The sharp end of the distal tibial chip can damage the tibialis posterior muscle, long flexor muscles of the toes and the flexor hallucis longus, 3. Every spiral fracture of the tibia is associated with disruption of the periosteum.

  16. Bone stress in runners with tibial stress fracture.

    PubMed

    Meardon, Stacey A; Willson, John D; Gries, Samantha R; Kernozek, Thomas W; Derrick, Timothy R

    2015-11-01

    Combinations of smaller bone geometry and greater applied loads may contribute to tibial stress fracture. We examined tibial bone stress, accounting for geometry and applied loads, in runners with stress fracture. 23 runners with a history of tibial stress fracture & 23 matched controls ran over a force platform while 3-D kinematic and kinetic data were collected. An elliptical model of the distal 1/3 tibia cross section was used to estimate stress at 4 locations (anterior, posterior, medial and lateral). Inner and outer radii for the model were obtained from 2 planar x-ray images. Bone stress differences were assessed using two-factor ANOVA (α=0.05). Key contributors to observed stress differences between groups were examined using stepwise regression. Runners with tibial stress fracture experienced greater anterior tension and posterior compression at the distal tibia. Location, but not group, differences in shear stress were observed. Stepwise regression revealed that anterior-posterior outer diameter of the tibia and the sagittal plane bending moment explained >80% of the variance in anterior and posterior bone stress. Runners with tibial stress fracture displayed greater stress anteriorly and posteriorly at the distal tibia. Elevated tibial stress was associated with smaller bone geometry and greater bending moments about the medial-lateral axis of the tibia. Future research needs to identify key running mechanics associated with the sagittal plane bending moment at the distal tibia as well as to identify ways to improve bone geometry in runners in order to better guide preventative and rehabilitative efforts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Total knee arthroplasty and fractures of the tibial plateau

    PubMed Central

    Softness, Kenneth A; Murray, Ryan S; Evans, Brian G

    2017-01-01

    Tibial plateau fractures are common injuries that occur in a bimodal age distribution. While there are various treatment options for displaced tibial plateau fractures, the standard of care is open reduction and internal fixation (ORIF). In physiologically young patients with higher demand and better bone quality, ORIF is the preferred method of treating these fractures. However, future total knee arthroplasty (TKA) is a consideration in these patients as post-traumatic osteoarthritis is a common long-term complication of tibial plateau fractures. In older, lower demand patients, ORIF is potentially less favorable for a variety of reasons, namely fixation failure and the need for delayed weight bearing. In some of these patients, TKA can be considered as primary mode of treatment. This paper will review the literature surrounding TKA as both primary treatment and as a salvage measure in patients with fractures of the tibial plateau. The outcomes, complications, techniques and surgical challenges are also discussed. PMID:28251061

  18. [Particular posteromedial and posterolateral approaches for the treatment of tibial head fractures].

    PubMed

    Lobenhoffer, P; Gerich, T; Bertram, T; Lattermann, C; Pohlemann, T; Tscheme, H

    1997-12-01

    Tibial plateau fractures with depression of posterior aspects of the proximal tibia cause significant therapeutic problems. Posterior fractures on the medial side are mainly highly instable fracture-dislocations (Moore type I). Posterolateral fractures usually cause massive depression and destruction of the chondral surface. Surgical exposure of these fractures from anterior requires major soft tissue dissection and has a significant complication rate. However, incomplete restoration of the joint surface results in chronic postero-inferior joint subluxation, osteoarthritis and pain. We present new specific approaches for posterior fracture types avoiding large skin incisions, but allowing for atraumatic exposure, reduction and fixation. Posteromedial fracture-dislocations are exposed by a direct posteromedial skin incision and a deep incision between medial collateral ligament and posterior oblique ligament. The posteromedial pillar and the posterior flare of the proximal tibia are visualized. The inferior extent of the joint fragment can be reduced by indirect techniques or direct manipulation of the fragment. Fixation is achieved with subchondral lag screws and an anti-glide plate at the tip of the fragment. Posterolateral fractures are exposed by a transfibular approach: the skin is incised laterally, the peroneal nerve is dissected free. The fibula neck is osteotomized, the tibiofibular syndesmosis is divided and the fibula neck is reflected upwards in one layer with the meniscotibial ligament and the iliotibial tract attachment. Reflexion of the fibula head relaxes the lateral collateral ligament, allows for lateral joint opening and internal rotation of the tibia and thus exposes the posterolateral and posterior aspect of the tibial plateau. Fixation and buttressing on the posterolateral side can be achieved easily with this approach. In closure, the fibula head is fixed back with a lag screw or a tension-band system. These two exposures can be combined in

  19. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.

    PubMed

    Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien

    2011-09-01

    The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.

  20. Tibial stress fracture after computer-navigated total knee arthroplasty.

    PubMed

    Massai, F; Conteduca, F; Vadalà, A; Iorio, R; Basiglini, L; Ferretti, A

    2010-06-01

    A correct alignment of the tibial and femoral component is one of the most important factors determining favourable long-term results of a total knee arthroplasty (TKA). The accuracy provided by the use of the computer navigation systems has been widely described in the literature so that their use has become increasingly popular in recent years; however, unpredictable complications, such as displaced or stress femoral or tibial fractures, have been reported to occur a few weeks after the operation. We present a case of a stress tibial fracture that occurred after a TKA performed with the use of a computer navigation system. The stress fracture, which eventually healed without further complications, occurred at one of the pinhole sites used for the placement of the tibial trackers.

  1. Comparison of tibial shaft ski fractures in children and adults.

    PubMed

    Hamada, Tomo; Matsumoto, Kazu; Ishimaru, Daichi; Sumi, Hiroshi; Shimizu, Katsuji

    2014-09-01

    To examine whether child and adult skiers have different risk factors or mechanisms of injury for tibial shaft fractures. Descriptive epidemiological study. Prospectively analyzed the epidemiologic factors, injury types, and injury mechanisms at Sumi Memorial Hospital. This study analyzed information obtained from 276 patients with tibial fractures sustained during skiing between 2004 and 2012. We focused on 174 ski-related tibial shaft fractures with respect to the following factors: age, gender, laterality of fracture, skill level, mechanism of fracture (fall vs collision), scene of injury (steepness of slope), snow condition, and weather. Fracture pattern was graded according to Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification and mechanical direction [external (ER) or internal rotation (IR)]. Tibial shaft fractures were the most common in both children (89.3%) and adults (47.4%). There were no significant differences in gender, side of fracture, mechanism of fracture, snow condition, or weather between children and adults. Skill levels were significantly lower in children than in adults (P < 0.0001). Type A fractures were more dominant in children (73 cases, 72.3%) than in adults (39 cases, 53.4%). There was significantly more ER in children than in adults (P < 0.0001). Among children, female patients had significantly more IR than ER; in contrast, among adults, women were injured by ER. We found significant differences in some of these parameters, suggesting that child and adult skiers have different risk factors or mechanisms of injury for tibial shaft fractures.

  2. Primary Ankle Arthrodesis for Severely Comminuted Tibial Pilon Fractures.

    PubMed

    Al-Ashhab, Mohamed E

    2017-03-01

    Management of severely comminuted, complete articular tibial pilon fractures (Rüedi and Allgöwer type III) remains a challenge, with few treatment options providing good clinical outcomes. Twenty patients with severely comminuted tibial pilon fractures underwent primary ankle arthrodesis with a retrograde calcaneal nail and autogenous fibular bone graft. The fusion rate was 100% and the varus malunion rate was 10%. Fracture union occurred at a mean of 16 weeks (range, 13-18 weeks) postoperatively. Primary ankle arthrodesis is a successful method for treating highly comminuted tibial pilon fractures, having a low complication rate and a high satisfaction score. [Orthopedics. 2017; 40(2):e378-e381.]. Copyright 2016, SLACK Incorporated.

  3. Delay in weight bearing in surgically treated tibial shaft fractures is associated with impaired healing: a cohort analysis of 166 tibial fractures.

    PubMed

    Houben, I B; Raaben, M; Van Basten Batenburg, M; Blokhuis, T J

    2018-04-09

    The relation between timing of weight bearing after a fracture and the healing outcome is yet to be established, thereby limiting the implementation of a possibly beneficial effect for our patients. The current study was undertaken to determine the effect of timing of weight bearing after a surgically treated tibial shaft fracture. Surgically treated diaphyseal tibial fractures were retrospectively studied between 2007 and 2015. The timing of initial weight bearing (IWB) was analysed as a predictor for impaired healing in a multivariate regression. Totally, 166 diaphyseal tibial fractures were included, 86 cases with impaired healing and 80 with normal healing. The mean age was 38.7 years (range 16-89). The mean time until IWB was significantly shorter in the normal fracture healing group (2.6 vs 7.4 weeks, p < 0.001). Correlation analysis yielded four possible confounders: infection requiring surgical intervention, fracture type, fasciotomy and open fractures. Logistic regression identified IWB as an independent predictor for impaired healing with an odds ratio of 1.13 per week delay (95% CI 1.03-1.25). Delay in initial weight bearing is independently associated with impaired fracture healing in surgically treated tibial shaft fractures. Unlike other factors such as fracture type or soft tissue condition, early resumption of weight bearing can be influenced by the treating physician and this factor therefore has a direct clinical relevance. This study indicates that early resumption of weight bearing should be the treatment goal in fracture fixation. 3b.

  4. Epidemiology of metatarsal stress fractures versus tibial and femoral stress fractures during elite training.

    PubMed

    Finestone, Aharon; Milgrom, Charles; Wolf, Omer; Petrov, Kaloyan; Evans, Rachel; Moran, Daniel

    2011-01-01

    The training of elite infantry recruits takes a year or more. Stress fractures are known to be endemic in their basic training and the clinical presentation of tibial, femoral, and metatarsal stress fractures are different. Stress fracture incidence during the subsequent progressively more demanding training is not known. The study hypothesis was that after an adaptation period, the incidence of stress fractures during the course of 1 year of elite infantry training would fall in spite of the increasingly demanding training. Seventy-six male elite infantry recruits were followed for the development of stress fractures during a progressively more difficult training program composed of basic training (1 to 14 weeks), advanced training (14 to 26 weeks), and unit training (26 to 52 weeks). Subjects were reviewed regularly and those with clinical suspicion of stress fracture were assessed using bone scan and X-rays. The incidence of stress fractures was 20% during basic training, 14% during advanced training and 23% during unit training. There was a statistically significant difference in the incidence of tibial and femoral stress fractures versus metatarsal stress fractures before and after the completion of phase II training at week 26 (p=0.0001). Seventy-eight percent of the stress fractures during phases I and II training were either tibial or femoral, while 91% of the stress fractures in phase III training were metatarsal. Prior participation in ball sports (p=0.02) and greater tibial length (p=0.05) were protective factors for stress fracture. The study hypothesis that after a period of soldier adaptation, the incidence of stress fractures would decrease in spite of the increasingly demanding elite infantry training was found to be true for tibial and femoral fractures after 6 months of training but not for metatarsal stress fractures. Further studies are required to understand the mechanism of this difference but physicians and others treating stress fractures

  5. Proximal third humeral shaft fractures -- a fracture entity not fully characterized by conventional AO classification.

    PubMed

    Stedtfeld, H W; Biber, R

    2014-01-01

    The retrospective study was made to evaluate the fracture patterns at the proximal humeral shaft for which the long version of a standard proximal humeral nail (PHNLV) has been used. The indication has been decided by the individual surgeons. Over a five year period 72 consecutive PHNLV cases of an acute fracture were identified and were included in the study. Mean patient age was 68.9 years. Gender ratio was m/f=22/50. 86.1% of the patients fractured their humerus by a fall, the rest by a high velocity accident. We analysed patient comorbidity, ASA score, osteoporosis, social status before accident, additional injuries affecting local soft tissues or other anatomic regions. We analysed the expansion of the fractures, dividing the humerus into five zones. Fracture morphology was categorized according to the standard AO/ASIF classification (if applicable). Comorbidities were found in 76.4% of the patients. Almost all patients (93.1%) had been living independently at home before the accident. 47.2% of patients had osteoporosis in their medical history. Five patients (6.9%) had a primary palsy of the radial nerve. Six fractures chosen for PHNLV fixation were clearly restricted to the humeral head. The remaining 66 fractures were located in the humeral shaft (AO region 12). There were 5 segmental fractures. Of the remaining 67 fractures affecting the proximal third of the humeral shaft 49.3 percent extended into the humeral head. 98 percent of these fractures displayed spiral morphology. Proximal humeral shaft fractures are amazingly similar to subtrochanteric and distal tibial shaft fractures: Spiral fracture types with different grades of comminution are absolutely dominant; a great proportion of the fractures extend into the humeral head with growing tendency of displacement if located closer to the humeral head. Diverging traction of deltoid and pectoralis muscle causes typical displacement if the fracture line runs in between their attachments substantiating the

  6. Tibial avulsion fracture of the posterior root of the medial meniscus in a skeletally-immature child - a case report.

    PubMed

    Matava, Matthew J; Kim, Young-Mo

    2011-01-01

    It has been theorized that a traumatic tibial avulsion fracture of the posterior root of the medial meniscus (MM) is the cause of the so-called meniscus ossicle (MO). We report the delayed appearance of a tibial avulsion fracture of the posterior root of the MM after a valgus, twisting injury in a 12-year-old boy with open physes. Magnetic resonance imaging (MRI) scans performed 3 days after the injury did not demonstrate a definitive tibial avulsion fracture of the posterior root of the MM; whereas, a repeat MRI for 3 months post-injury did. Medial extrusion of the MM was also noted on the 3 month MRI. Arthroscopic reattachment of the avulsed posterior root of the MM using a trans-physeal nonabsorbable suture tied over a proximal tibia staple was performed. Follow-up MRI at 6 months postoperatively demonstrated healing of the tibial avulsion fracture of the posterior root of the MM in an anatomic position. The patient had a complete resolution of symptoms and there was no angular deformity or limb-length discrepancy at 2 years postoperatively. To our knowledge, this is the first report describing a tibial avulsion fracture of the posterior root of the MM in a skeletally-immature patient successfully treated by a trans-physeal arthroscopic suture. This case also illustrates the development of the MO of the posterior root of the MM. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Tibial rotational osteotomy for idiopathic torsion. A comparison of the proximal and distal osteotomy levels.

    PubMed

    Krengel, W F; Staheli, L T

    1992-10-01

    A retrospective analysis was done of 52 rotational tibial osteotomies (RTOs) performed on 35 patients with severe idiopathic tibial torsion. Thirty-nine osteotomies were performed at the proximal or midtibial level. Thirteen were performed at the distal tibial level with a technique previously described by one of the authors. Serious complications occurred in five (13%) of the proximal and in none of the distal RTOs. For severe and persisting idiopathic tibial torsion, the authors recommend correction by RTO at the distal level. Proximal level osteotomy is indicated only when a varus or valgus deformity required concurrent correction.

  8. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    PubMed

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate

  9. Understanding the etiology of the posteromedial tibial stress fracture.

    PubMed

    Milgrom, Charles; Burr, David B; Finestone, Aharon S; Voloshin, Arkady

    2015-09-01

    Previous human in vivo tibial strain measurements from surface strain gauges during vigorous activities were found to be below the threshold value of repetitive cyclical loading at 2500 microstrain in tension necessary to reduce the fatigue life of bone, based on ex vivo studies. Therefore it has been hypothesized that an intermediate bone remodeling response might play a role in the development of tibial stress fractures. In young adults tibial stress fractures are usually oblique, suggesting that they are the result of failure under shear strain. Strains were measured using surface mounted unstacked 45° rosette strain gauges on the posterior aspect of the flat medial cortex just below the tibial midshaft, in a 48year old male subject while performing vertical jumps, staircase jumps and running up and down stadium stairs. Shear strains approaching 5000 microstrain were recorded during stair jumping and vertical standing jumps. Shear strains above 1250 microstrain were recorded during runs up and down stadium steps. Based on predictions from ex vivo studies, stair and vertical jumping tibial shear strain in the test subject was high enough to potentially produce tibial stress fracture subsequent to repetitive cyclic loading without necessarily requiring an intermediate remodeling response to microdamage. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Comparison of intraoperative anthropometric measurements of the proximal tibia and tibial component in total knee arthroplasty.

    PubMed

    Miyatake, Naohisa; Sugita, Takehiko; Aizawa, Toshimi; Sasaki, Akira; Maeda, Ikuo; Kamimura, Masayuki; Fujisawa, Hirokazu; Takahashi, Atsushi

    2016-09-01

    Precise matching of the tibial component and resected bony surfaces and proper rotational implanting of the tibial component are crucial for successful total knee arthroplasty. We aimed to analyze the exact anthropometric proximal tibial data of Japanese patients undergoing total knee arthroplasty and correlate the measurements with the dimensions of current total knee arthroplasty systems. A total of 703 knees in 566 Japanese patients who underwent total knee arthroplasty for osteoarthritis were included. The bone resection in the proximal tibia was performed perpendicular to the tibial axis in the frontal plane. Measurements of the proximal tibia were intraoperatively obtained after proximal tibial preparation. There were significant positive correlations between the lateral anteroposterior and medial anteroposterior and mediolateral dimensions. A progressive decrease in the mediolateral/lateral anteroposterior ratio with an increasing lateral anteroposterior dimension or the mediolateral/anteroposterior ratio with an increasing anteroposterior dimension was observed. The lateral anteroposterior dimension was smaller than the medial anteroposterior dimension by a mean of 4.8 ± 2.0 mm. The proximal tibia exhibited asymmetry between the lateral and medial plateaus. A comparison of the morphological data and dimensions of the implants, one of which was a symmetric tibial component (NexGen) and the others were asymmetric (Genesis II and Persona), indicated that an asymmetric tibial component could be beneficial to maximize tibial plateau coverage. This study provided important reference data for designing a proper tibial component for Japanese people. The proximal tibial cut surface was asymmetric. There was wide dispersion in the lateral anteroposterior, medial anteroposterior, and mediolateral dimensions depending on the patient. Our data showed that the tibial components of the Genesis II and Persona rather than that of the NexGen may be preferable for

  11. Anterior tibial stress fractures treated with anterior tension band plating in high-performance athletes.

    PubMed

    Cruz, Alexandre Santa; de Hollanda, João Paris Buarque; Duarte, Aires; Hungria Neto, José Soares

    2013-06-01

    The non-surgical treatment of anterior tibial cortex stress fractures requires long periods of abstention from sports activities and often results in non-union. Many different surgical techniques have already been previously described to treat these fractures, but there is no consensus on the best treatment. We describe the outcome of treatment using anterior tibial tension band plating in three high-performance athletes (4 legs) with anterior tibial cortex stress fractures. Tibial osteosynthesis with a 3.5-mm locking compression plate in the anterolateral aspect of the tibia was performed in all patients diagnosed with anterior tibial stress fracture after September 2010 at Santa Casa Hospital. All of the fractures were consolidated within a period of 3 months after surgery, allowing for an early return to pre-injury levels of competitive sports activity. There were no infection, non-union, malunion or anterior knee pain complications. Anterior tibial tension band plating leads to prompt fracture consolidation and is a good alternative for the treatment of anterior tibial cortex stress fractures. Bone grafts were shown to be unnecessary.

  12. The Contribution of SPECT/CT in the Diagnosis of Stress Fracture of the Proximal Tibia.

    PubMed

    Okudan, Berna; Coşkun, Nazım; Arıcan, Pelin

    2018-02-01

    Stress fractures are injuries most commonly seen in the lower limbs and are usually caused by repetitive stress. While the distal and middle third of the tibia is the most frequent site for stress fractures (almost 50%), stress fractures of the proximal tibia is relatively rare and could be confused with other types of tibial fractures, thus altering management plans for the clinician. Early diagnosis of stress fractures is also important to avoid complications. Imaging plays an important role in the diagnosis of stress fractures, especially bone scan. Combined with single-photon emission computed tomography/computed tomography (SPECT/CT) it is an important imaging technique for stress fractures in both upper and lower extremities, and is widely preferred over other imaging techniques. In this case, we present the case of a 39-year-old male patient diagnosed with stress fracture of the proximal tibia and demonstrate the contribution of CT scan fused with SPECT imaging in the early diagnosis of stress fracture prior to other imaging modalities.

  13. Minimally invasive surgical technique: Percutaneous external fixation combined with titanium elastic nails for selective treatment of tibial fractures.

    PubMed

    Tu, Kai-Kai; Zhou, Xian-Ting; Tao, Zhou-Shan; Chen, Wei-Kai; Huang, Zheng-Liang; Sun, Tao; Zhou, Qiang; Yang, Lei

    2015-12-01

    Several techniques have been described to treat tibial fractures, which respectively remains defects. This article presents a novel intra- and extramedullary fixation technique: percutaneous external fixator combined with titanium elastic nails (EF-TENs system). The purpose of this study is to introduce this new minimally invasive surgical technique and selective treatment of tibial fractures, particularly in segmental fractures, diaphysis fractures accompanied with distal or proximal bone subfissure, or fractures with poor soft-tissue problems. Following ethical approval, thirty-two patients with tibial fractures were treated by the EF-TENs system between January 2010 and December 2012. The follow-up studies included clinical and radiographic examinations. All relevant outcomes were recorded during follow-up. All thirty-two patients were achieved follow-ups. According to the AO classification, 3 Type A, 9 Type B and 20 Type C fractures were included respectively. According to the Anderson-Gustilo classification, there were 5 Type Grade II, 3 Type Grade IIIA and 2 Type Grade IIIB. Among 32 patients, 8 of them were segmental fractures. 12 fractures accompanied with bone subfissure. Results showed no nonunion case, with an average time of 23.7 weeks (range, 14-32 weeks). Among them, there were 3/32 delayed union patients and 0/32 malunion case. 4/32 patients developed a pin track infection and no patient suffered deep infection. The external fixator was removed with a mean time of 16.7 weeks (range, 10-26 weeks). Moreover, only 1/32 patient suffered with the restricted ROM of ankle, none with the restricted ROM of knee. This preliminary study indicated that the EF-TENs system, as a novel intra- and extramedullary fixation technique, had substantial effects on selective treatment of tibial fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Intraoperative study on anthropometry and gender differences of the proximal tibial plateau at the arthroplasty resection surface.

    PubMed

    Yang, Bo; Yu, Jiakuo; Gong, Xi; Chen, Lianxu; Wang, Yongjian; Wang, Jian; Wang, Haijun; Zhang, Jiying

    2014-01-01

    The tibial plateau is asymmetric with a larger medial plateau. We observed from clinical practice that the shape of the tibial plateau does not always present a larger medial plateau. Tibial plateau also showed other shapes. The purpose of this study was to analyze the anthropometric data of the proximal tibia in a large group of Chinese patients undergoing total knee arthroplasty and to investigate the morphology of the resected proximal tibial surface and its gender differences. A total of 822 knees (164 males, 658 females) from the Chinese population were measured intraoperatively for medial anteroposterior (MAP) and lateral anteroposterior (LAP) dimensions of the resected proximal tibial surface. The difference of MAP and LAP (DML) was also calculated as MAP minus LAP. We then classified the data into three groups based on the DML (<-2, -2 to 2, and >2 mm) to analyze the morphology of the proximal tibia and its distribution between male and female. The shape of proximal tibial plateau was of three types: larger medial plateau type, symmetric type, and larger lateral plateau type. There were significant differences between males and females in relation to the shape distribution of the proximal tibial plateau (P < 0.05). Most of the proximal tibial plateau was asymmetric, with 517 of 822 (62.9%) tibia having a DML >2 mm and 120 of 822 (14.6%) tibia having a DML<-2 mm. Only 185 of 822 (22.5%) tibia had a DML between -2 and 2 mm. The results of this study can be used as a guideline to design tibial components with different DMLs to better match the different anthropometry of the resected tibial surface.

  15. Tibial Eminence Involvement With Tibial Plateau Fracture Predicts Slower Recovery and Worse Postoperative Range of Knee Motion.

    PubMed

    Konda, Sanjit R; Driesman, Adam; Manoli, Arthur; Davidovitch, Roy I; Egol, Kenneth A

    2017-07-01

    To examine 1-year functional and clinical outcomes in patients with tibial plateau fractures with tibial eminence involvement. Retrospective analysis of prospectively collected data. Academic Medical Center. All patients who presented with a tibial plateau fracture (Orthopaedic Trauma Association (OTA) 41-B and 41-C). Patients were divided into fractures with a tibial eminence component (+TE) and those without (-TE) cohorts. All patients underwent similar surgical approaches and fixation techniques for fractures. No tibial eminence fractures received fixation specifically. Short musculoskeletal functional assessment (SMFA), pain (Visual Analogue Scale), and knee range-of-motion (ROM) were evaluated at 3, 6, and 12 months postoperatively and compared between cohorts. Two hundred ninety-three patients were included for review. Patients with OTA 41-C fractures were more likely to have an associated TE compared with 41-B fractures (63% vs. 28%, P < 0.01). At 3 months postoperatively, the +TE cohort was noted to have worse knee ROM (75.16 ± 51 vs. 86.82 ± 53 degree, P = 0.06). At 6 months, total SMFA and knee ROM was significantly worse in the +TE cohort (29 ± 17 vs. 21 ± 18, P ≤ 0.01; 115.6 ± 20 vs. 124.1 ± 15, P = 0.01). By 12 months postoperatively, only knee ROM remained significantly worse in the +TE cohort (118.7 ± 15 vs. 126.9 ± 13, P < 0.01). Multivariate analysis revealed that tibial eminence involvement was a significant predictor of ROM at 6 and 12 months and SFMA at 6 months. Body mass index was found to be a significant predictor of ROM and age was a significant predictor of total SMFA at all time points. Knee ROM remains worse throughout the postoperative period in the +TE cohort. Functional outcome improves less rapidly in the +TE cohort but achieves similar results by 1 year. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  16. Modified arthroscopic suture fixation of a displaced tibial eminence fracture.

    PubMed

    Lehman, Ronald A; Murphy, Kevin P; Machen, M Shaun; Kuklo, Timothy R

    2003-02-01

    This study describes a new arthroscopic method using a whip-stitch technique for treating a displaced type III tibial eminence fracture. A 12-year-old girl who sustained a displaced type III tibial eminence fracture was treated with arthroscopic fixation using the Arthrosew disposable suture device (Surgical Dynamics, Norwalk, CT) to place a whip stitch into the anterior cruciate ligament (ACL). The Arthrex ACL guide (Arthrex, Naples, FL) was used to reduce the avulsed tibial spine fragment. Sutures were then passed through the tibial tunnel and secured over a bony bridge with the knee in 20 degrees of flexion. At 9 months, the patient has a full range of motion with normal Lachman and anterior drawer testing, and she has returned to competitive basketball. Radiographs show complete fracture healing. KT-1000 and isokinetic testing at 9-month follow-up show only minimal side-to-side differences. The Arthrosew device provides a significant advantage in the treatment of type III and IV fractures of the tibial eminence by obtaining arthroscopic fixation within the substance of the ACL, thus obviating arthrotomy and hardware placement. This technique also restores the proper length and tension to the ACL, and provides a simplified, reproducible method of treatment for this injury.

  17. Hybrid external fixation in the treatment of tibial pilon fractures: A retrospective analysis of 162 fractures.

    PubMed

    Galante, Vito N; Vicenti, Giovanni; Corina, Gianfranco; Mori, Claudio; Abate, Antonella; Picca, Girolamo; Conserva, Vito; Speciale, Domenico; Scialpi, Lorenzo; Tartaglia, Nicola; Caiaffa, Vincenzo; Moretti, Biagio

    2016-10-01

    To determine the efficacy of hybrid external fixation in the treatment of tibial pilon fractures. Retrospective, multicentre study. Adult patients with tibial pilon fractures treated with hybrid external fixation. Fracture reduction with ligamentotaxis and fixation with XCaliber hybrid external fixator. Fracture union, complications, functional outcome (Mazur Ankle Score). Union was obtained in 159 fractures at an average of 125days; there were three delayed unions and three non-unions. The most frequent complication was superficial pin-track infections (48), all of which responded to local wound care and antibiotics. There were no deep infections and no DVT. Only one fracture had loss of reduction that required frame revision. The overall functional scores were 91 (excellent) for AO/OTA type A fractures, 89 (good) for type B fractures, and 75 (satisfactory) for type C fractures. Hybrid external fixation is an effective method of stabilising tibial pilon fractures, particularly those with marked comminution. The minimally-invasive technique and stable fixation enable early mobilisation, with good functional results and minimal complications. Level IV Case series. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Management of tibial fractures using a circular external fixator in two calves.

    PubMed

    Aithal, Hari Prasad; Kinjavdekar, Prakash; Amarpal; Pawde, Abhijit Motiram; Singh, Gaj Raj; Setia, Harish Chandra

    2010-07-01

    To report the repair of tibial diaphyseal fractures in 2 calves using a circular external skeletal fixator (CEF). Clinical report. Crossbred calves (n=2; age: 6 months; weight: 55 and 60 kg). Mid-diaphyseal tibial fractures were repaired by the use of a 4-ring CEF (made of aluminum rings with 2 mm K-wires) alone in 1 calf and in combination with hemicerclage wiring in 1 calf. Both calves had good weight bearing with moderate lameness postoperatively. Fracture healing occurred by day 60 in 1 calf and by day 30 in calf 2. The CEF was well maintained and tolerated by both calves through fracture healing. Joint mobility and limb usage improved gradually after CEF removal. CEF provided a stable fixation of tibial fractures and healing within 60 days and functional recovery within 90 days. CEF can be safely and successfully used for the management of selected tibial fractures in calves.

  19. Minimally-invasive plate osteosynthesis in distal tibial fractures: Results and complications.

    PubMed

    Vidović, Dinko; Matejčić, Aljoša; Ivica, Mihovil; Jurišić, Darko; Elabjer, Esmat; Bakota, Bore

    2015-11-01

    Distal tibial or pilon fractures are usually the result of combined compressive and shear forces, and may result in instability of the metaphysis, with or without articular depression, and injury to the soft tissue. The complexity of injury, lack of muscle cover and poor vascularity make these fractures difficult to treat. Surgical treatment of distal tibial fractures includes several options: external fixation, IM nailing, ORIF and minimally-invasive plate osteosynthesis (MIPO). Management of distal tibial fractures with MIPO enables preservation of soft tissue and remaining blood supply. This is a report of a series of prospectively studied closed distal tibial and pilon fractures treated with MIPO. A total of 21 patients with closed distal tibial or pilon fractures were enrolled in the study between March 2008 and November 2013 and completed follow-up. Demographic characteristics, mechanism of injury, time required for union, ankle range of motion and complications were recorded. Fractures were classified according to the AO/OTA classification. Nineteen patients were initially managed with an ankle-spanning external fixator. When the status of the soft tissue had improved and swelling had subsided enough, a definitive internal fixation with MIPO was performed. Patients were invited for follow-up examinations at 3 and 6 weeks and then at intervals of 6 to 8 weeks until 12 months. Mean age of the patients was 40.1 years (range 19-67 years). Eighteen cases were the result of high-energy trauma and three were the result of low-energy trauma. According to the AO/OTA classification there were extraarticular and intraarticular fractures, but only simple articular patterns without depression or comminution. The average time for fracture union was 19.7 weeks (range 12-38 weeks). Mean range of motion was 10° of dorsiflexion (range 5-15°) and 28.3° of plantar flexion (range 20-35°). Three cases were metalwork-related complications. Two patients underwent plate removal

  20. Return to Sport After Tibial Shaft Fractures

    PubMed Central

    Robertson, Greg A. J.; Wood, Alexander M.

    2015-01-01

    Context: Acute tibial shaft fractures represent one of the most severe injuries in sports. Return rates and return-to-sport times after these injuries are limited, particularly with regard to the outcomes of different treatment methods. Objective: To determine the current evidence for the treatment of and return to sport after tibial shaft fractures. Data Sources: OVID/MEDLINE (PubMed), EMBASE, CINAHL, Cochrane Collaboration Database, Web of Science, PEDro, SPORTDiscus, Scopus, and Google Scholar were all searched for articles published from 1988 to 2014. Study Selection: Inclusion criteria comprised studies of level 1 to 4 evidence, written in the English language, that reported on the management and outcome of tibial shaft fractures and included data on either return-to-sport rate or time. Studies that failed to report on sporting outcomes, those of level 5 evidence, and those in non–English language were excluded. Study Design: Systematic review. Level of Evidence: Level 4. Data Extraction: The search used combinations of the terms tibial, tibia, acute, fracture, athletes, sports, nonoperative, conservative, operative, and return to sport. Two authors independently reviewed the selected articles and created separate data sets, which were subsequently combined for final analysis. Results: A total of 16 studies (10 retrospective, 3 prospective, 3 randomized controlled trials) were included (n = 889 patients). Seventy-six percent (672/889) of the patients were men, with a mean age of 27.7 years. Surgical management was assessed in 14 studies, and nonsurgical management was assessed in 8 studies. Return to sport ranged from 12 to 54 weeks after surgical intervention and from 28 to 182 weeks after nonsurgical management (mean difference, 69.5 weeks; 95% CI, –83.36 to −55.64; P < 0.01). Fractures treated surgically had a return-to-sport rate of 92%, whereas those treated nonsurgically had a return rate of 67% (risk ratio, 1.37; 95% CI, 1.20 to 1.57; P < 0

  1. Fracture line morphology of complex proximal humeral fractures.

    PubMed

    Hasan, Afsana P; Phadnis, Joideep; Jaarsma, Ruurd L; Bain, Gregory I

    2017-10-01

    The aim of this study was to assess proximal humeral fracture patterns using 3-dimensional computed tomography images and relate them to the normal osseous landmarks and soft-tissue attachments. Forty-eight 3-dimensional computed tomography scans of proximal humeral fractures were retrospectively collected, and the fractures were transcribed onto proximal humeral templates. We analyzed the common location and orientation of the fracture lines, with a focus on fractures of the articular surface, tuberosities, metaphysis, and proximal diaphysis. These fractures were compared with the attachments of the rotator cuff and glenohumeral capsule. Fifty-two percent of the fractures involved the articular surface. No fractures passed through the bicipital groove, and fractures were more commonly found on the posterior lesser tuberosity and on the anterior greater tuberosity, coinciding with the intervals between the rotator cuff tendon insertions. Intracapsular fractures of the calcar were more common (68%) than extracapsular fractures (32%). On the anterolateral aspect of the proximal humerus, fractures radiated from the articular margin, vertically down through the tuberosity zone between the rotator cuff footprints, meeting horizontally oriented fractures in the metaphyseal zone. On the posterior aspect, vertical fractures from the tuberosity zone continued downward to the metaphyseal zone adjacent to the infraspinatus and teres minor footprints. Fractures of the proximal humerus follow characteristic patterns. Fractures frequently split the greater tuberosity and are closely related to the intervals of the rotator cuff attachments. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  2. TIBIAL SHAFT FRACTURES.

    PubMed

    Kojima, Kodi Edson; Ferreira, Ramon Venzon

    2011-01-01

    The long-bone fractures occur most frequently in the tibial shaft. Adequate treatment of such fractures avoids consolidation failure, skewed consolidation and reoperation. To classify these fractures, the AO/OTA classification method is still used, but it is worthwhile getting to know the Ellis classification method, which also includes assessment of soft-tissue injuries. There is often an association with compartmental syndrome, and early diagnosis can be achieved through evaluating clinical parameters and constant clinical monitoring. Once the diagnosis has been made, fasciotomy should be performed. It is always difficult to assess consolidation, but the RUST method may help in this. Radiography is assessed in two projections, and points are scored for the presence of the fracture line and a visible bone callus. Today, the dogma of six hours for cleaning the exposed fracture is under discussion. It is considered that an early start to intravenous antibiotic therapy and the lesion severity are very important. The question of early or late closure of the lesion in an exposed fracture has gone through several phases: sometimes early closure has been indicated and sometimes late closure. Currently, whenever possible, early closure of the lesion is recommended, since this diminishes the risk of infection. Milling of the canal when the intramedullary nail is introduced is still a controversial subject. Despite strong personal positions in favor of milling, studies have shown that there may be some advantage in relation to closed fractures, but not in exposed fractures.

  3. Evaluation of Fibular Fracture Type vs Location of Tibial Fixation of Pilon Fractures.

    PubMed

    Busel, Gennadiy A; Watson, J Tracy; Israel, Heidi

    2017-06-01

    Comminuted fibular fractures can occur with pilon fractures as a result of valgus stress. Transverse fibular fractures can occur with varus deformation. No definitive guide for determining the proper location of tibial fixation exists. The purpose of this study was to identify optimal plate location for fixation of pilon fractures based on the orientation of the fibular fracture. One hundred two patients with 103 pilon fractures were identified who were definitively treated at our institution from 2004 to 2013. Pilon fractures were classified using the AO/OTA classification and included 43-A through 43-C fractures. Inclusion criteria were age of at least 18 years, associated fibular fracture, and definitive tibial plating. Patients were grouped based on the fibular component fracture type (comminuted vs transverse), and the location of plate fixation (medial vs lateral) was noted. Radiographic outcomes were assessed for mechanical failures. Forty fractures were a result of varus force as evidenced by transverse fracture of the fibula and 63 were due to valgus force with a comminuted fibula. For the transverse fibula group, 14.3% mechanical complications were noted for medially placed plate vs 80% for lateral plating ( P = .006). For the comminuted fibular group, 36.4% of medially placed plates demonstrated mechanical complications vs 16.7% for laterally based plates ( P = .156). Time to weight bearing as tolerated was also noted to be significant between groups plated medially and laterally for the comminuted group ( P = .013). Correctly assessing the fibular component for pilon fractures provides valuable information regarding deforming forces. To limit mechanical complications, tibial plates should be applied in such a way as to resist the original deforming forces. Level of Evidence Level III, comparative study.

  4. Angular stable plates in proximal meta-epiphyseal tibial fractures: study of joint restoration and clinical and functional evaluation.

    PubMed

    Giannotti, S; Giovannelli, D; Dell'Osso, G; Bottai, V; Bugelli, G; Celli, F; Citarelli, C; Guido, G

    2016-04-01

    The tibial plateau fractures involve one of the main weight bearing joints of the human body. The goals of surgical treatment are anatomical reduction, articular surface reconstruction and high primary stability. The aim of this study was to evaluate the clinical and functional outcomes after internal plate fixation of this kind of fractures. From January 2009 to December 2012, we treated 75 cases of tibial plateau fracture with angular stable plates. We used Rasmussen Score and the Knee Society Score for the clinical and functional evaluation. Twenty-five cases that underwent hardware removal had arthroscopic and CT evaluation of the joint. No complications occurred. The clinical and functional evaluation, performed by the KSS and Rasmussen Score, highlighted the high percentage of good-to-excellent results (over 90 %). In every case, the range of motion was good with flexion >90°. Arthroscopy showed the presence of chondral damage in 100 % of patients. In all the cases, we found that X-ray images seem better than the CT images. Angular stable plates allow to obtain a good primary stability, permitting an early joint recovery with an excellent range of motion. Avoiding to perform a knee arthrotomy at the time of fracture reduction could prove to be an advantage in terms of functional recovery. The meniscus on the injured bone should be preserved in order to maintain good function of the joint. X-ray images remain the gold standard in checking the progression of post-traumatic osteoarthritis.

  5. Partial proximal tibia fractures

    PubMed Central

    Raschke, Michael J.; Kittl, Christoph; Domnick, Christoph

    2017-01-01

    Partial tibial plateau fractures may occur as a consequence of either valgus or varus trauma combined with a rotational and axial compression component. High-energy trauma may result in a more complex and multi-fragmented fracture pattern, which occurs predominantly in young people. Conversely, a low-energy mechanism may lead to a pure depression fracture in the older population with weaker bone density. Pre-operative classification of these fractures, by Müller AO, Schatzker or novel CT-based methods, helps to understand the fracture pattern and choose the surgical approach and treatment strategy in accordance with estimated bone mineral density and the individual history of each patient. Non-operative treatment may be considered for non-displaced intra-articular fractures of the lateral tibial condyle. Intra-articular joint displacement ⩾ 2 mm, open fractures or fractures of the medial condyle should be reduced and fixed operatively. Autologous, allogenic and synthetic bone substitutes can be used to fill bone defects. A variety of minimally invasive approaches, temporary osteotomies and novel techniques (e.g. arthroscopically assisted reduction or ‘jail-type’ screw osteosynthesis) offer a range of choices for the individual and are potentially less invasive treatments. Rehabilitation protocols should be carefully planned according to the degree of stability achieved by internal fixation, bone mineral density and other patient-specific factors (age, compliance, mobility). To avoid stiffness, early functional mobilisation plays a major role in rehabilitation. In the elderly, low-energy trauma and impression fractures are indicators for the further screening and treatment of osteoporosis. Cite this article: EFORT Open Rev 2017;2. DOI: 10.1302/2058-5241.2.160067. Originally published online at www.efortopenreviews.org PMID:28630761

  6. Temporary Fixation Using a Long Femoral-tibial Nail to Treat a Displaced Medial Tibial Plateau Fracture in a 90-year-old Patient: A Case Report.

    PubMed

    Batta, V; Sinha, S; Trompeter, A

    2017-01-01

    Tibial plateau fractures are complex injuries in the elderly population. When traditional methods of fixation are not suitable, an alternative method needs to be chosen for a favorable outcome. We demonstrate a previously undescribed treatment for displaced tibial plateau fractures in the very elderly with poor soft-tissue integrity. A 90-year-old woman suffered an open, Gustilo Grade IIIA, displaced fracture of the tibial plateau. An intramedullary knee arthrodesis, the femoral-tibial nail was used to temporarily stabilize her fracture. She was able to weight bear immediately postfixation. A long femoral-tibial nail allows favorable fracture and soft tissue healing, ease of nursing and immediate full weight-bearing. It shows good promise and should be considered as a management option when traditional methods are not applicable in select patients.

  7. Biomechanical analysis of posteromedial tibial plateau split fracture fixation.

    PubMed

    Zeng, Zhi-Min; Luo, Cong-Feng; Putnis, Sven; Zeng, Bing-Fang

    2011-01-01

    The purpose of this study was to compare the biomechanical strength of four different fixation methods for a posteromedial tibial plateau split fracture. Twenty-eight tibial plateau fractures were simulated using right-sided synthetic tibiae models. Each fracture model was randomly instrumented with one of the four following constructs, anteroposterior lag-screws, an anteromedial limited contact dynamic compression plate (LC-DCP), a lateral locking plate, or a posterior T-shaped buttress plate. Vertical subsidence of the posteromedial fragment was measured from 500 N to 1500 N during biomechanical testing, the maximum load to failure was also determined. It was found that the posterior T-shaped buttress plate allowed the least subsidence of the posteromedial fragment and produced the highest mean failure load than each of the other three constructs (P=0.00). There was no statistical significant difference between using lag screws or an anteromedial LC-DCP construct for the vertical subsidence at a 1500 N load and the load to failure (P>0.05). This study showed that a posterior-based buttress technique is biomechanically the most stable in-vitro fixation method for posteromedial split tibial plateau fractures, with AP screws and anteromedial-based LC-DCP are not as stable for this type of fracture. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. High-energy fractures of the tibial plateau. Knee function after longer follow-up.

    PubMed

    Weigel, Dennis P; Marsh, J Lawrence

    2002-09-01

    Studies of the long-term outcomes of treatment of fractures of the tibial plateau have included wide mixtures of fracture types and mostly low-energy split and split-depression fractures. The long-term results of treatment of high-energy intra-articular proximal tibial fractures are unknown. The purpose of this study was to assess the function of the knee and the development of arthrosis at a minimum of five years after injury in a consecutive series of patients in whom a high-energy fracture of the tibial plateau had been treated with a uniform technique of external fixation. Between July 1988 and December 1994, thirty patients with a total of thirty-one fractures of the tibial plateau were treated with a monolateral external fixator and limited internal fixation of the articular surface. Follow-up data on twenty-four knees in twenty-three patients were obtained at a mean of ninety-eight months. Twenty patients (twenty knees) returned specifically for the study, at which time they completed an Iowa Knee Score questionnaire and a Short Form-36 (SF-36) general health survey, a physical examination was performed, and weight-bearing radiographs were made. The results of the SF-36 evaluations for fourteen patients and the Knee Scores for twelve were compared with those obtained five years previously, at two to four years after the injury. After healing, no patient required a secondary reconstructive procedure. The range of motion of the knee averaged 3 degrees of extension to 120 degrees flexion, which was an average of 87% of the total arc of the contralateral knee. The average Iowa Knee Score was 90 points (range, 72 to 100 points). For twelve patients, the Iowa Knee Score previously recorded at two to four years averaged 92 points, as did the score at the time of the latest follow-up. Thirteen patients rated their outcome as excellent; six, as good; and three, as fair. Fifteen patients were working, and ten of them were performing strenuous labor. Radiographs showed

  9. Outcomes of Surgical Treatment for Anterior Tibial Stress Fractures in Athletes: A Systematic Review.

    PubMed

    Chaudhry, Zaira S; Raikin, Steven M; Harwood, Marc I; Bishop, Meghan E; Ciccotti, Michael G; Hammoud, Sommer

    2017-12-01

    Although most anterior tibial stress fractures heal with nonoperative treatment, some may require surgical management. To our knowledge, no systematic review has been conducted regarding surgical treatment strategies for the management of chronic anterior tibial stress fractures from which general conclusions can be drawn regarding optimal treatment in high-performance athletes. This systematic review was conducted to evaluate the surgical outcomes of anterior tibial stress fractures in high-performance athletes. Systematic review; Level of evidence, 4. In February 2017, a systematic review of the PubMed, MEDLINE, Cochrane, SPORTDiscus, and CINAHL databases was performed to identify studies that reported surgical outcomes for anterior tibial stress fractures. Articles meeting the inclusion criteria were screened, and reported outcome measures were documented. A total of 12 studies, published between 1984 and 2015, reporting outcomes for the surgical treatment of anterior tibial stress fractures were included in this review. All studies were retrospective case series. Collectively, surgical outcomes for 115 patients (74 males; 41 females) with 123 fractures were evaluated in this review. The overall mean follow-up was 23.3 months. The most common surgical treatment method reported in the literature was compression plating (n = 52) followed by drilling (n = 33). Symptom resolution was achieved in 108 of 123 surgically treated fractures (87.8%). There were 32 reports of complications, resulting in an overall complication rate of 27.8%. Subsequent tibial fractures were reported in 8 patients (7.0%). Moreover, a total of 17 patients (14.8%) underwent a subsequent procedure after their initial surgery. Following surgical treatment for anterior tibial stress fracture, 94.7% of patients were able to return to sports. The available literature indicates that surgical treatment of anterior tibial stress fractures is associated with a high rate of symptom resolution and return

  10. Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty.

    PubMed

    Tanikake, Yohei; Hayashi, Koji; Ogawa, Munehiro; Inagaki, Yusuke; Kawate, Kenji; Tomita, Tetsuya; Tanaka, Yasuhito

    2016-12-01

    A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated longitudinal bending stress, leading to fatigue breaking at the anterior side of the cone, followed by the tibial insert cone fracture at the anterior side of the cone, resulting in fracture at the base of the cone. This analysis shows the risk of tibial insert cone fracture due to longitudinal stress in mobile-bearing posterior-stabilized total knee arthroplasty in which an insert is designed to highly conform to the femoral component.

  11. Temporary Fixation Using a Long Femoral-tibial Nail to Treat a Displaced Medial Tibial Plateau Fracture in a 90-year-old Patient: A Case Report

    PubMed Central

    Batta, V; Sinha, S; Trompeter, A

    2017-01-01

    Introduction: Tibial plateau fractures are complex injuries in the elderly population. When traditional methods of fixation are not suitable, an alternative method needs to be chosen for a favorable outcome. We demonstrate a previously undescribed treatment for displaced tibial plateau fractures in the very elderly with poor soft-tissue integrity. Case Report: A 90-year-old woman suffered an open, Gustilo Grade IIIA, displaced fracture of the tibial plateau. An intramedullary knee arthrodesis, the femoral-tibial nail was used to temporarily stabilize her fracture. She was able to weight bear immediately postfixation. Conclusion: A long femoral-tibial nail allows favorable fracture and soft tissue healing, ease of nursing and immediate full weight-bearing. It shows good promise and should be considered as a management option when traditional methods are not applicable in select patients. PMID:29181350

  12. Multiple Tibial Insufficiency Fractures in the Same Tibia

    PubMed Central

    Defoort, Saartje; Mertens, Peter

    2011-01-01

    Stress fractures were first described by Briethaupt in 1855. Since then, there have been many discussions in the literature concerning stress fractures, which have been described in both weight-bearing and non-weight-bearing bones. Currently, the tibia is the most frequent location, but multiple stress fractures in the same tibia are rare. This paper presents an unusual case of a 60-year-old woman with multiple tibial stress fractures of spontaneous onset. PMID:23569673

  13. Tibial Plateau Fractures in Elderly Patients

    PubMed Central

    Vemulapalli, Krishna C.; Gary, Joshua L.; Donegan, Derek J.

    2016-01-01

    Tibial plateau fractures are common in the elderly population following a low-energy mechanism. Initial evaluation includes an assessment of the soft tissues and surrounding ligaments. Most fractures involve articular depression leading to joint incongruity. Treatment of these fractures may be complicated by osteoporosis, osteoarthritis, and medical comorbidities. Optimal reconstruction should restore the mechanical axis, provide a stable construct for mobilization, and reestablish articular congruity. This is accomplished through a variety of internal or external fixation techniques or with acute arthroplasty. Regardless of the treatment modality, particular focus on preservation and maintenance of the soft tissue envelope is paramount. PMID:27551570

  14. The treatment options for posterior malleolar fractures in tibial spiral fractures.

    PubMed

    Guo, Jialiang; Liu, Lei; Yang, Zongyou; Hou, Zhiyong; Chen, Wei; Zhang, Yingze

    2017-09-01

    The posterior malleolar fracture (PMF) in tibial spiral fractures are a common type of complication that occurs in tibial fractures. However, the indication of fixation for posterior fractures is still under debate and varies between different surgeons'. It is not unusual to find the smaller PMF (<25%), which could be treated conservatively within guidelines, treated with internal fixation in clinic. The aim of this study is to evaluate the clinical outcomes of tibial spiral fractures with PMF and provide proper guidance for the treatment of this special fracture. A total of 284 cases of spiral fractures combined with PMF were collected and analyzed. Demographic data, fragment size (classified by 25% involvement of ankle joint), time to weight-bearing and functional scores post-operatively were recorded. The ankle-hindfoot scale of the American Orthopaedic Foot and Ankle Society (AOFAS), a visual analogue scale (VAS) pain score, assessment of dorsiflexion restriction and arthritis scale were used as the main evaluations. Forty patients with a larger PMF (≥25%) and 72 with smaller ones (<25%) were fixed and categorized as the fixation group (FG). In the nonfixation group (NG), the corresponding numbers were four and 168 patients respectively. A total of 279 PMF were classified as large posterolateral triangular fragment carrying the posterior half of the fibular notch and intra-incisural posterolateral fragment involving one-fourth to one-third of the fibular notch. However, no obvious differences were observed in terms of the clinical outcomes in PMF involving one-fourth to one-third of the fibular notch. In the treatment of smaller PMF (<25%) of this type, there were no obvious differences in the functional outcomes between fixed (SF) and nonfixed PMF (SN). Many patients with smaller PMFs were fixated, but functional outcomes of SF were not better than those of SN. There is no need to emphasize other factors guiding the treatment of PMF involving one-fourth to

  15. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

    PubMed

    Gupta, Rakesh K; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2010-12-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.

  16. Posttraumatic tibia valga: a case demonstrating asymmetric activity at the proximal growth plate on technetium bone scan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zionts, L.E.; Harcke, H.T.; Brooks, K.M.

    1987-07-01

    Posttraumatic tibia valga is a well-recognized complication following fracture of the upper tibial metaphysis in young children. We present a case of a child who developed a valgus deformity following fracture of the proximal tibia and fibula in which quantitative bone scintigraphy at 5 months after injury demonstrated increased uptake at the proximal tibial growth plate with proportionally greater uptake on the medial side. This finding suggests that the valgus deformity in this patient was due to a relative increase in vascularity and consequent overgrowth of the medial portion of the proximal tibial physis.

  17. Immediate effects of modified landing pattern on a probabilistic tibial stress fracture model in runners.

    PubMed

    Chen, T L; An, W W; Chan, Z Y S; Au, I P H; Zhang, Z H; Cheung, R T H

    2016-03-01

    Tibial stress fracture is a common injury in runners. This condition has been associated with increased impact loading. Since vertical loading rates are related to the landing pattern, many heelstrike runners attempt to modify their footfalls for a lower risk of tibial stress fracture. Such effect of modified landing pattern remains unknown. This study examined the immediate effects of landing pattern modification on the probability of tibial stress fracture. Fourteen experienced heelstrike runners ran on an instrumented treadmill and they were given augmented feedback for landing pattern switch. We measured their running kinematics and kinetics during different landing patterns. Ankle joint contact force and peak tibial strains were estimated using computational models. We used an established mathematical model to determine the effect of landing pattern on stress fracture probability. Heelstrike runners experienced greater impact loading immediately after landing pattern switch (P<0.004). There was an increase in the longitudinal ankle joint contact force when they landed with forefoot (P=0.003). However, there was no significant difference in both peak tibial strains and the risk of tibial stress fracture in runners with different landing patterns (P>0.986). Immediate transitioning of the landing pattern in heelstrike runners may not offer timely protection against tibial stress fracture, despite a reduction of impact loading. Long-term effects of landing pattern switch remains unknown. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Do Tibial Plateau Fractures Worsen Outcomes of Knee Ligament Injuries? A Matched Cohort Analysis

    PubMed Central

    Cinque, Mark E.; Godin, Jonathan A.; Moatshe, Gilbert; Chahla, Jorge; Kruckeberg, Bradley M.; Pogorzelski, Jonas; LaPrade, Robert F.

    2017-01-01

    Background: Tibial plateau fractures account for a small portion of all fractures; however, these fractures can pose a surgical challenge when occurring concomitantly with ligament injuries. Purpose/Hypothesis: The purpose of this study was to compare 2-year outcomes of soft tissue reconstruction with or without a concomitant tibial plateau fracture and open reduction internal fixation. We hypothesized that patients with a concomitant tibial plateau fracture at the time of soft tissue surgery would have inferior outcomes compared with patients without an associated tibial plateau fracture. Study Design: Cohort study; Level of evidence, 3. Methods: Forty patients were included in this study: 8 in the fracture group and 32 in the matched control group. Inclusion criteria for the fracture group included patients who were at least 18 years old at the time of surgery and sustained a tibial plateau fracture and a concomitant injury of the anterior cruciate ligament, posterior cruciate ligament, medial collateral ligament, or fibular collateral ligament in isolation or any combination of cruciate or collateral ligaments and who subsequently underwent isolated or combined ligament reconstruction. Patients were excluded if they underwent prior ipsilateral knee surgery, sustained additional bony injuries, or sustained an isolated extra-articular ligament injury at the time of injury. Each patient with a fracture was matched with 4 patients from a control group who had no evidence of a tibial plateau fracture but underwent the same soft tissue reconstruction procedure. Results: Patients in the fracture group improved significantly from preoperatively to postoperatively with respect to Short Form–12 (P < .05) and Western Ontario and McMaster Universities Osteoarthritis Index total scores (P < .05). The Lysholm (P = .075) and Tegner scores (P = .086) also improved, although this was not statistically significant. Patients in the control group improved significantly from

  19. Tibial plateau fracture after primary anatomic double-bundle anterior cruciate ligament reconstruction: a case report.

    PubMed

    Gobbi, Alberto; Mahajan, Vivek; Karnatzikos, Georgios

    2011-05-01

    Tibial plateau fracture after primary anatomic double-bundle anterior cruciate ligament (ACL) reconstruction is rare. To our knowledge, this is the first case report of a tibial plateau fracture after primary anatomic double-bundle ACL reconstruction. In our patient the tibial plateau fracture occurred after a torsional injury to the involved extremity. The fracture occurred 4.5 years after the ACL reconstruction. The fracture was intra-articular Schatzker type IV and had a significant displacement. The patient was treated operatively by open reduction-internal fixation. He recovered well. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Negative pressure wound therapy for Gustilo Anderson grade IIIb open tibial fractures.

    PubMed

    Park, Chul Hyun; Shon, Oog Jin; Kim, Gi Beom

    2016-09-01

    Traditionally, Gustilo Anderson grade IIIb open tibial fractures have been treated by initial wide wound debridement, stabilization of fracture with external fixation, and delayed wound closure. The purpose of this study is to evaluate the clinical and radiological results of staged treatment using negative pressure wound therapy (NPWT) for Gustilo Anderson grade IIIb open tibial fractures. 15 patients with Gustilo Anderson grade IIIb open tibial fractures, treated using staged protocol by a single surgeon between January 2007 and December 2011 were reviewed in this retrospective study. The clinical results were assessed using a Puno scoring system for severe open fractures of the tibia at the last followup. The range of motion (ROM) of the knee and ankle joints and postoperative complication were evaluated at the last followup. The radiographic results were assessed using time to bone union, coronal and sagittal angulations and a shortening at the last followup. The mean score of Puno scoring system was 87.4 (range 67-94). The mean ROM of the knee and ankle joints was 121.3° (range 90°-130°) and 37.7° (range 15°-50°), respectively. Bone union developed in all patients and the mean time to union was 25.3 weeks (range 16-42 weeks). The mean coronal angulation was 2.1° (range 0-4°) and sagittal was 2.7° (range 1-4°). The mean shortening was 4.1 mm (range 0-8 mm). Three patients had partial flap necrosis and 1 patient had total flap necrosis. There was no superficial and deep wound infection. Staged treatment using NPWT decreased the risks of infection and requirement of flap surgeries in Gustilo Anderson grade IIIb open tibial fractures. Therefore, staged treatment using NPWT could be a useful treatment option for Gustilo Anderson grade IIIb open tibial fractures.

  1. Surgical treatment of refractory tibial stress fractures in elite dancers: a case series.

    PubMed

    Miyamoto, Ryan G; Dhotar, Herman S; Rose, Donald J; Egol, Kenneth

    2009-06-01

    Treatment of tibial stress fractures in elite dancers is centered on rest and activity modification. Surgical intervention in refractory cases has important implications affecting the dancers' careers. Refractory tibial stress fractures in dancers can be treated successfully with drilling and bone grafting or intramedullary nailing. Case series; Level of evidence, 4. Between 1992 and 2006, 1757 dancers were evaluated at a dance medicine clinic; 24 dancers (1.4%) had 31 tibial stress fractures. Of that subset, 7 (29.2%) elite dancers with 8 tibial stress fractures were treated operatively with either intramedullary nailing or drilling and bone grafting. Six of the patients were followed up closely until they were able to return to dance. One patient was available only for follow-up phone interview. Data concerning their preoperative treatment regimens, operative procedures, clinical union, radiographic union, and time until return to dance were recorded and analyzed. The mean age of the surgical patients at the time of stress fracture was 22.6 years. The mean duration of preoperative symptoms before surgical intervention was 25.8 months. Four of the dancers were male and 3 were female. All had failed nonoperative treatment regimens. Five patients (5 tibias) underwent drilling and bone grafting of the lesion, and 2 patients (3 tibias) with completed fractures or multiple refractory stress fractures underwent intramedullary nailing. Clinical union was achieved at a mean of 6 weeks and radiographic union at 5.1 months. Return to full dance activity was at an average of 6.5 months postoperatively. Surgical intervention for tibial stress fractures in dancers who have not responded to nonoperative management allowed for resolution of symptoms and return to dancing with minimal morbidity.

  2. Locked compression plating for peri- and intra-articular fractures around the knee.

    PubMed

    Jain, Jitesh Kumar; Asif, Naiyer; Ahmad, Suhail; Qureshi, Owais; Siddiqui, Yasir Salam; Rana, Ashish

    2013-11-01

    To evaluate the role of locked compression plates (LCPs) in management of peri- and intra-articular fractures around the knee. Twenty distal femoral and 20 proximal tibial fractures were fixed with LCPs. The types of femoral fractures were A1 (four), A2 (three), A3 (two), C1 (one), C2 (seven) and C3 (three). The types of tibial fractures were A2 (one), A3 (two), B2 (two), C1 (four), C2 (five) and C3 (six). All patients were followed up for up to 18 months (mean, 12 months). Fourteen patients with distal femoral fractures and 19 with proximal tibial fractures underwent surgery using a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. The others were treated by open reduction. The average time of fixation was 8 days after injury (0-31 days). Knee Society scores were used for clinical and functional assessment. All fractures, except one of the distal femur and one of the proximal tibia, united. The mean union times for distal femoral and proximal tibial fractures were 15.2 and 14.9 weeks, respectively. One patient with a distal femoral fracture had implant failure. One patient was quadriplegic and did not recover the ability to walk. The average Knee Society scores of the remaining 18 patients were 82.66 (excellent) and 77.77 (functional score, good). There was one case of implant failure and one of screw breakage in distal femoral fractures. One case of nonunion occurred in a proximal tibial fracture. Provided it is applied with proper understanding of biomechanics, LCP is one of the best available options for management of challenging peri- and intra-articular fractures. © 2013 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  3. A Case of Nonunion Avulsion Fracture of the Anterior Tibial Eminence

    PubMed Central

    Atsumi, Satoru; Arai, Yuji; Nakagawa, Shuji; Inoue, Hiroaki; Ikoma, Kazuya; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    2016-01-01

    Avulsion fracture of the anterior tibial eminence is an uncommon injury. If bone union does not occur, knee extension will be limited by impingement of the avulsed fragment and knee instability will be induced by dysfunction of the anterior cruciate ligament (ACL). This report describes a 55-year-old woman who experienced an avulsion fracture of the right anterior tibial eminence during recreational skiing. Sixteen months later, she presented at our hospital with limitation of right knee extension. Plain radiography showed nonunion of the avulsion fracture region, and arthroscopy showed that the avulsed fragment impinged the femoral intercondylar notch during knee extension. The anterior region of the bony fragment was debrided arthroscopically until the knee could be extended completely. There was no subsequent instability, and the patient was able to climb a mountain 6 months after surgery. These findings indicate that arthroscopic debridement of an avulsed fragment for nonunion of an avulsion fracture of the anterior tibial eminence is a minimally invasive and effective treatment for middle-aged and elderly patients with a low level of sports activity. PMID:27119035

  4. [Operative treatment for complex tibial plateau fractures].

    PubMed

    Song, Qi-Zhi; Li, Tao

    2012-03-01

    To explore the surgical methods and clinical evaluation of complex tibial plateau fractures resulted from high-energy injuries. From March 2006 to May 2009,48 cases with complex tibial plateau fractures were treated with open reduction and plate fixation, including 37 males and 11 females, with an average age of 37 years (ranged from 18 to 63 years). According to Schatzker classification, 16 cases were type IV, 20 cases type V and 12 cases type VI. All patients were examined by X-ray flim and CT scan. The function of knee joint were evaluated according to postoperative follow-up X-ray and Knee Merchant Rating. Forty-eight patients were followed up with a mean time of 14 months. According to Knee Merchant Rating, 24 cases got excellent results, 16 cases good, 6 cases fair and 2 cases poor. Appropriate operation time, anatomical reduction, suitable bone graft and reasonable rehabilitation exercises can maximally recovery the function of knee joint.

  5. Bone microarchitecture of the tibial plateau in skeletal health and osteoporosis.

    PubMed

    Krause, Matthias; Hubert, Jan; Deymann, Simon; Hapfelmeier, Alexander; Wulff, Birgit; Petersik, Andreas; Püschel, Klaus; Amling, Michael; Hawellek, Thelonius; Frosch, Karl-Heinz

    2018-05-07

    Impaired bone structure poses a challenge for the treatment of osteoporotic tibial plateau fractures. As knowledge of region-specific structural bone alterations is a prerequisite to achieving successful long-term fixation, the aim of the current study was to characterize tibial plateau bone structure in patients with osteoporosis and the elderly. Histomorphometric parameters were assessed by high-resolution peripheral quantitative computed tomography (HR-pQCT) in 21 proximal tibiae from females with postmenopausal osteoporosis (mean age: 84.3 ± 4.9 years) and eight female healthy controls (45.5 ± 6.9 years). To visualize region-specific structural bony alterations with age, the bone mineral density (Hounsfield units) was additionally analyzed in 168 human proximal tibiae. Statistical analysis was based on evolutionary learning using globally optimal regression trees. Bone structure deterioration of the tibial plateau due to osteoporosis was region-specific. Compared to healthy controls (20.5 ± 4.7%) the greatest decrease in bone volume fraction was found in the medio-medial segments (9.2 ± 3.5%, p < 0.001). The lowest bone volume was found in central segments (tibial spine). Trabecular connectivity was severely reduced. Importantly, in the anterior and posterior 25% of the lateral and medial tibial plateaux, trabecular support and subchondral cortical bone thickness itself were also reduced. Thinning of subchondral cortical bone and marked bone loss in the anterior and posterior 25% of the tibial plateau should require special attention when osteoporotic patients require fracture fixation of the posterior segments. This knowledge may help to improve the long-term, fracture-specific fixation of complex tibial plateau fractures in osteoporosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Acute changes in foot strike pattern and cadence affect running parameters associated with tibial stress fractures.

    PubMed

    Yong, Jennifer R; Silder, Amy; Montgomery, Kate L; Fredericson, Michael; Delp, Scott L

    2018-05-18

    Tibial stress fractures are a common and debilitating injury that occur in distance runners. Runners may be able to decrease tibial stress fracture risk by adopting a running pattern that reduces biomechanical parameters associated with a history of tibial stress fracture. The purpose of this study was to test the hypothesis that converting to a forefoot striking pattern or increasing cadence without focusing on changing foot strike type would reduce injury risk parameters in recreational runners. Running kinematics, ground reaction forces and tibial accelerations were recorded from seventeen healthy, habitual rearfoot striking runners while running in their natural running pattern and after two acute retraining conditions: (1) converting to forefoot striking without focusing on cadence and (2) increasing cadence without focusing on foot strike. We found that converting to forefoot striking decreased two risk factors for tibial stress fracture: average and peak loading rates. Increasing cadence decreased one risk factor: peak hip adduction angle. Our results demonstrate that acute adaptation to forefoot striking reduces different injury risk parameters than acute adaptation to increased cadence and suggest that both modifications may reduce the risk of tibial stress fractures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Biomechanical analysis of four different fixations for the posterolateral shearing tibial plateau fracture.

    PubMed

    Zhang, Wei; Luo, Cong-Feng; Putnis, Sven; Sun, Hui; Zeng, Zhi-Min; Zeng, Bing-Fang

    2012-03-01

    The posterolateral shearing tibial plateau fracture is uncommon in the literature, however with the increased usage of computer tomography (CT), the incidence of these fractures is no longer as low as previously thought. Few studies have concentrated on this fracture, least of all using a biomechanical model. The purpose of this study was to compare and analyse the biomechanical characteristics of four different types of internal fixation to stabilise the posterolateral shearing tibial plateau fracture. Forty synthetic tibiae (Synbone, right) simulated the posterolateral shearing fracture models and these were randomly assigned into four groups; Group A was fixed with two anterolateral lag screws, Group B with an anteromedial Limited Contact Dynamic Compression Plate (LC-DCP), Group C with a lateral locking plate, and Group D with a posterolateral buttress plate. Vertical displacement of the posterolateral fragment was measured using three different strengths of axial loading force, and finally loaded until fixation failure. It was concluded that the posterolateral buttress plate is biomechanically the strongest fixation method for the posterolateral shearing tibial plateau fracture. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Management of Open Tibial Shaft Fractures: Does the Timing of Surgery Affect Outcomes?

    PubMed

    Duyos, Oscar A; Beaton-Comulada, David; Davila-Parrilla, Ariel; Perez-Lopez, Jose Carlos; Ortiz, Krystal; Foy-Parrilla, Christian; Lopez-Gonzalez, Francisco

    2017-03-01

    Open tibial shaft fractures require emergent care. Treatment with intravenous antibiotics and fracture débridement within 6 to 24 hours is recommended. Few studies have examined outcomes when surgical treatment is performed >24 hours after occurrence of the fracture. This retrospective study included 227 patients aged ≥18 years with isolated open tibial shaft fractures in whom the time to initial débridement was >24 hours. The statistical analysis was based on time from injury to surgical débridement, Gustilo-Anderson classification, method of fixation, union status, and infection status. Fractures débrided within 24 to 48 hours and 48 to 96 hours after injury did not show a statistically significant difference in terms of infection rates (P = 0.984). External fixation showed significantly greater infection rates (P = 0.044) and nonunion rates (P = 0.001) compared with intramedullary nailing. Open tibial shaft fractures should be débrided within 24 hours after injury. Our data indicate that after the 24-hour period and up to 4 days, the risk of infection remains relatively constant independent of the time to débridement. Patients treated with external fixation had more complications than did patients treated with other methods of fixation. Primary reamed intramedullary nailing appears to be a reasonable option for the management of Gustilo-Anderson types 1 and 2 open tibial shaft fractures. Level III retrospective study.

  9. Fracture reduction and primary ankle arthrodesis: a reliable approach for severely comminuted tibial pilon fracture.

    PubMed

    Beaman, Douglas N; Gellman, Richard

    2014-12-01

    Posttraumatic arthritis and prolonged recovery are typical after a severely comminuted tibial pilon fracture, and ankle arthrodesis is a common salvage procedure. However, few reports discuss the option of immediate arthrodesis, which may be a potentially viable approach to accelerate overall recovery in patients with severe fracture patterns. (1) How long does it take the fracture to heal and the arthrodesis to fuse when primary ankle arthrodesis is a component of initial fracture management? (2) How do these patients fare clinically in terms of modified American Orthopaedic Foot and Ankle Society (AOFAS) scores and activity levels after this treatment? (3) Does primary ankle arthrodesis heal in an acceptable position when anterior ankle arthrodesis plates are used? During a 2-year period, we performed open fracture reduction and internal fixation in 63 patients. Eleven patients (12 ankles) with severely comminuted high-energy tibial pilon fractures were retrospectively reviewed after surgical treatment with primary ankle arthrodesis and fracture reduction. Average patient age was 58 years, and minimum followup was 6 months (average, 14 months; range, 6-22 months). Anatomically designed anterior ankle arthrodesis plates were used in 10 ankles. Ring external fixation was used in nine ankles with concomitant tibia fracture or in instances requiring additional fixation. Clinical evaluation included chart review, interview, the AOFAS ankle-hindfoot score, and radiographic evaluation. All of the ankle arthrodeses healed at an average of 4.4 months (range, 3-5 months). One patient had a nonunion at the metaphyseal fracture, which healed with revision surgery. The average AOFAS ankle-hindfoot score was 83 with 88% having an excellent or good result. Radiographic and clinical analysis confirmed a plantigrade foot without malalignment. No patients required revision surgery for malunion. Primary ankle arthrodesis combined with fracture reduction for the severely comminuted

  10. Part II: arthroscopic treatment of tibial plateau fractures: intercondylar eminence avulsion fractures.

    PubMed

    Lubowitz, James H; Elson, Wylie S; Guttmann, Dan

    2005-01-01

    Arthroscopic reduction and internal fixation (ARIF) of tibial intercondylar eminence fractures is the emerging state-of-the-art. ARIF is recommended for displaced type III fractures and should be considered for all cases of displaced type II fractures. Fractures without displacement after closed reduction require careful evaluation to rule out meniscal entrapment. Subjective results of ARIF are uniformly excellent, despite reports of objective anteroposterior laxity. Early range-of-motion exercises are essential to prevent loss of extension. Repair using nonabsorbable suture fixation, when of adequate strength to allow early range-of-motion, has the advantages of eliminating the risks of comminution of the fracture fragment, posterior neurovascular injury, and need for hardware removal, compared with ARIF using screws.

  11. Tibial component considerations in bicruciate-retaining total knee arthroplasty: A 3D MRI evaluation of proximal tibial anatomy.

    PubMed

    Saxena, Vishal; Anari, Jason B; Ruutiainen, Alexander T; Voleti, Pramod B; Stephenson, Jason W; Lee, Gwo-Chin

    2016-08-01

    Restoration of normal anatomy and proper ligament balance are theoretical prerequisites for reproducing physiological kinematics with bicruciate-retaining total knee arthroplasty (TKA). The purpose of this study was to use a 3D MRI technique to evaluate the topography of the proximal tibia and outline considerations in tibial component design for bicruciate-retaining TKA. We identified 100 consecutive patients (50 males and 50 females) between ages 20 and 40 years with knee MRIs without arthritis, dysplasia, ACL tears, or prior knee surgery. A novel 3D MRI protocol coordinating axial, coronal, and sagittal images was used to measure: 1) medial and lateral posterior tibial slopes; 2) medial and lateral coronal slopes; and 3) distance from the anterior tibia to the ACL footprint. There was no overall difference in medial and lateral posterior tibial slopes (5.5° (95% CI 5.0 to 6.0°) vs. 5.4° (95% CI 4.8 to 6.0°), respectively (p=0.80)), but 41 patients had side-to-side differences greater than 3°. The medial coronal slope was greater than the lateral coronal slope (4.6° (95% CI 4.0 to 5.1°) vs. 3.3° (95% CI 2.9 to 3.7°), respectively (p<0.0001)). Females had less clearance between the anterior tibia and ACL footprint than males (10.8mm (95% CI 10.4 to 11.2mm) vs. 13.0mm (95% CI 12.5 to 13.5mm), respectively (p<0.0001)). Due to highly variable proximal tibial topography, a monoblock bicruciate-retaining tibial baseplate may not reproduce normal anatomy in all patients. Level IV - Anatomic research study. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Proximal femoral fractures.

    PubMed

    Webb, Lawrence X

    2002-01-01

    Fractures of the proximal femur include fractures of the head, neck, intertrochanteric, and subtrochanteric regions. Head fractures commonly accompany dislocations. Neck fractures and intertrochanteric fractures occur with greatest frequency in elderly patients with a low bone mineral density and are produced by low-energy mechanisms. Subtrochanteric fractures occur in a predominantly strong cortical osseous region which is exposed to large compressive stresses. Implants used to address these fractures must be able to accommodate significant loads while the fractures consolidate. Complications secondary to these injuries produce significant morbidity and include infection, nonunion, malunion, decubitus ulcers, fat emboli, deep venous thrombosis, pulmonary embolus, pneumonia, myocardial infarction, stroke, and death.

  13. Time dependent loss of trabecular bone in human tibial plateau fractures.

    PubMed

    Solomon, Lucian Bogdan; Kitchen, David; Anderson, Paul Hamill; Yang, Dongqing; Starczak, Yolandi; Kogawa, Masakazu; Perilli, Egon; Smitham, Peter Jonathan; Rickman, Mark Sean; Thewlis, Dominic; Atkins, Gerald James

    2018-05-22

    We investigated if time between injury and surgery affects cancellous bone properties in patients suffering tibial plateau fractures (TPF), in terms of structural integrity and gene expression controlling bone loss. A cohort of 29 TPF, operated 1-17 days post-injury, had biopsies from the fracture and an equivalent contralateral limb site, at surgery. Samples were assessed using micro-computed tomography and real-time RT-PCR analysis for the expression of genes known to be involved in bone remodeling and fracture healing. Significant decreases in the injured vs control side were observed for bone volume fraction (BV/TV, -13.5 ± 6.0%, p = 0.011), trabecular number (Tb.N, -10.5 ± 5.9%, p = 0.041) and trabecular thickness (Tb.Th, -4.6 ± 2.5%, p = 0.033). Changes in these parameters were more evident in patients operated 5-17 days post-injury, compared to those operated in the first 4 days post injury. A significant negative association was found between Tb.Th (r = -0.54, p < 0.01) and BV/TV (r = -0.39, p < 0.05) in relation to time post-injury in the injured limb. Both BV/TV and Tb.Th were negatively associated with expression of key molecular markers of bone resorption, CTSK, ACP5 and the ratio of RANKL:OPG mRNA. These structure/gene expression relationships did not exist in the contralateral tibial plateau of these patients. This study demonstrated that there is a significant early time-dependent bone loss in the proximal tibia after TPF. This bone loss was significantly associated with altered expression of genes typically involved in the process of osteoclastic bone resorption but possibly also by osteocytes. The mechanism of early bone loss in such fractures should be a subject of further investigation. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  14. Minimally invasive treatment of tibial pilon fractures through arthroscopy and external fixator-assisted reduction.

    PubMed

    Luo, Huasong; Chen, Liaobin; Liu, Kebin; Peng, Songming; Zhang, Jien; Yi, Yang

    2016-01-01

    The aim of this study was to evaluate the clinical outcome of tibial pilon fractures treated with arthroscopy and assisted reduction with an external fixator. Thirteen patients with tibial pilon fractures underwent assisted reduction for limited lower internal fixation with an external fixator under arthroscopic guidance. The weight-bearing time was decided on the basis of repeat radiography of the tibia 3 months after surgery. Postoperative ankle function was evaluated according to the Mazur scoring system. Healing of fractures was achieved in all cases, with no complications such as severe infection, skin necrosis, or an exposed plate. There were 9 excellent, 2 good, and 2 poor outcomes, scored according to the Mazur system. The acceptance rate was 85%. Arthroscopy and external fixator-assisted reduction for the minimally invasive treatment of tibial pilon fractures not only produced less trauma but also protected the soft tissues and blood supply surrounding the fractures. External fixation could indirectly provide reduction and effective operative space for arthroscopic implantation, especially for AO type B fractures and partial AO type C1 fractures.

  15. Arthroscopic evaluation of soft tissue injuries in tibial plateau fractures: retrospective analysis of 98 cases.

    PubMed

    Abdel-Hamid, Mohamed Zaki; Chang, Chung-Hsun; Chan, Yi-Sheng; Lo, Yang-Pin; Huang, Jau-Wen; Hsu, Kuo-Yao; Wang, Ching-Jen

    2006-06-01

    This investigation arthroscopically assesses the frequency of soft tissue injury in tibial plateau fracture according to the severity of fracture patterns. We hypothesized that use of arthroscopy to evaluate soft tissue injury in tibial plateau fractures would reveal a greater number of associated injuries than have previously been reported. From March 1996 to December 2003, 98 patients with closed tibial plateau fractures were treated with arthroscopically assisted reduction and osteosynthesis, with precise diagnosis and management of associated soft tissue injuries. Arthroscopic findings for associated soft tissue injuries were recorded, and the relationship between fracture type and soft tissue injury was then analyzed. The frequency of associated soft tissue injury in this series was 71% (70 of 98). The menisci were injured in 57% of subjects (56 in 98), the anterior cruciate ligament (ACL) in 25% (24 of 98), the posterior cruciate ligament (PCL) in 5% (5 of 98), the lateral collateral ligament (LCL) in 3% (3 of 98), the medial collateral ligament (MCL) in 3% (3 of 98), and the peroneal nerve in 1% (1 of 98); none of the 98 patients exhibited injury to the arteries. No significant association was noted between fracture type and incidence of meniscus, PCL, LCL, MCL, artery, and nerve injury. However, significantly higher injury rates for the ACL were observed in type IV and VI fractures. Soft tissue injury was associated with all types of tibial plateau fracture. Menisci (peripheral tear) and ACL (bony avulsion) were the most commonly injured sites. A variety of soft tissue injuries are common with tibial plateau fracture; these can be diagnosed with the use of an arthroscope. Level III, diagnostic study.

  16. Complex tibial fracture outcomes following treatment with low-intensity pulsed ultrasound.

    PubMed

    Leung, Kwok-Sui; Lee, Wing-Sze; Tsui, Hon-For; Liu, Paul Po-Lung; Cheung, Wing-Hoi

    2004-03-01

    A clinical study was conducted to investigate the effect of low-intensity pulsed ultrasound (US) stimulation (LIPUS) on the healing of complex tibial fractures. Thirty complex tibial fractures were randomly assigned to the treatment with LIPUS (n = 16) or by a dummy machine (sham-exposed: n = 14). The fractures were immobilized by either internal or external fixations according to the clinical indications. LIPUS was given 20 min/day for 90 days. Fracture healing was monitored by clinical, radiological, densitometric and biochemical assessments. The LIPUS-treated group showed statistically significantly better healing, as demonstrated by all assessments. Complications were minimal in the LIPUS group. There were two cases of delayed union, with one in each group. There were two cases of infection in the control group. The delayed-union cases were subsequently treated by LIPUS and the infection cases were treated with standard protocol. Fracture healing in these patients was again treated by LIPUS.

  17. Distinct hip and rearfoot kinematics in female runners with a history of tibial stress fracture.

    PubMed

    Milner, Clare E; Hamill, Joseph; Davis, Irene S

    2010-02-01

    Cross-sectional controlled laboratory study. To investigate the kinematics of the hip, knee, and rearfoot in the frontal and transverse planes in female distance runners with a history of tibial stress fracture. Tibial stress fractures are a common overuse injury in runners, accounting for up to half of all stress fractures. Abnormal kinematics of the lower extremity may contribute to abnormal musculoskeletal load distributions, leading to an increased risk of stress fractures. Thirty female runners with a history of tibial stress fracture were compared to 30 age-matched and weekly-running-distance-matched control subjects with no previous lower extremity bony injuries. Kinematic and kinetic data were collected using a motion capture system and a force platform, respectively, as subjects ran in the laboratory. Selected variables of interest were compared between the groups using a multivariate analysis of variance (MANOVA). Peak hip adduction and peak rearfoot eversion angles were greater in the stress fracture group compared to the control group. Peak knee adduction and knee internal rotation angles and all joint angles at impact peak were similar between the groups. Runners with a previous tibial stress fracture exhibited greater peak hip adduction and rearfoot eversion angles during the stance phase of running compared to healthy controls. A consequence of these mechanics may be altered load distribution within the lower extremity, predisposing individuals to stress fracture.

  18. An unusual stress fracture: Bilateral posterior longitudinal stress fracture of tibia.

    PubMed

    Malkoc, Melih; Korkmaz, Ozgur; Ormeci, Tugrul; Oltulu, Ismail; Isyar, Mehmet; Mahirogulları, Mahir

    2014-01-01

    Stress fractures (SF) occur when healthy bone is subjected to cyclic loading, which the normal carrying range capacity is exceeded. Usually, stress fractures occur at the metatarsal bones, calcaneus, proximal or distal tibia and tends to be unilateral. This article presents a 58-year-old male patient with bilateral posterior longitudinal tibial stress fractures. A 58 years old male suffering for persistent left calf pain and decreased walking distance for last one month and after imaging studies posterior longitudinal tibial stress fracture was detected on his left tibia. After six months the patient was admitted to our clinic with the same type of complaints in his right leg. All imaging modalities and blood counts were performed and as a result longitudinal posterior tibial stress fractures were detected on his right tibia. Treatment of tibial stress fracture includes rest and modified activity, followed by a graded return to activity commensurate with bony healing. We have applied the same treatment protocol and our results were acceptable but our follow up time short for this reason our study is restricted for separate stress fractures of the posterior tibia. Although the main localization of tibial stress fractures were unilateral, anterior and transverse pattern, rarely, like in our case, the unusual bilateral posterior localization and longitudinal pattern can be seen. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Mortality Following Periprosthetic Proximal Femoral Fractures Versus Native Hip Fractures.

    PubMed

    Boylan, Matthew R; Riesgo, Aldo M; Paulino, Carl B; Slover, James D; Zuckerman, Joseph D; Egol, Kenneth A

    2018-04-04

    The number of periprosthetic proximal femoral fractures is expected to increase with the increasing prevalence of hip arthroplasties. While native hip fractures have a well-known association with mortality, there are currently limited data on this outcome among the subset of patients with periprosthetic proximal femoral fractures. Using the New York Statewide Planning and Research Cooperative System, we identified patients from 60 to 99 years old who were admitted to a hospital in the state with a periprosthetic proximal femoral fracture (n = 1,655) or a native hip (femoral neck or intertrochanteric) fracture (n = 97,231) between 2006 and 2014. Within the periprosthetic fracture cohort, the indication for the existing implant was not available in the data set. We used mixed-effects regression models to compare mortality at 1 and 6 months and 1 year for periprosthetic compared with native hip fractures. The risk of mortality for patients who sustained a periprosthetic proximal femoral fracture was no different from that for patients who sustained a native hip fracture at 1 month after injury (3.2% versus 4.6%; odds ratio [OR], 0.90; 95% confidence interval [CI], 0.68 to 1.19; p = 0.446), but was lower at 6 months (3.8% versus 6.5%; OR, 0.74; 95% CI, 0.57 to 0.95; p = 0.020) and 1 year (9.7% versus 15.9%; OR, 0.71; 95% CI, 0.60 to 0.85; p < 0.001). Among periprosthetic proximal femoral fractures, factors associated with a significantly increased risk of mortality at 1 year included advanced age, male sex, and higher Deyo comorbidity scores. In the acute phase, any type of hip fracture appears to confer a similar risk of death. Over the long term, however, periprosthetic proximal femoral fractures are associated with lower mortality rates than native hip fractures, even after accounting for age and comorbidities. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  20. Outcome of intramedullary interlocking SIGN nail in tibial diaphyseal fracture.

    PubMed

    Khan, Irfanullah; Javed, Shahzad; Khan, Gauhar Nawaz; Aziz, Amer

    2013-03-01

    To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). Case series. Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, from September 2008 to August 2009. Fifty patients aged 14 - 60 years, of either gender were included, who had closed and Gustilo type I and II open fractures reported in 2 weeks, whose closed reduction was not possible or was unsatisfactory and fracture was located 7 cm below knee joint to 7 cm above ankle joint. Fractures previously treated with external fixator, infected fractures and unfit patients were excluded. All fractures were fixed with intramedullary interlocking SIGN nail and were followed clinically and radiographically for union and for any implant failure. Forty one (88%) patients had united fracture within 6 months, 5 (10%) patients had delayed union while 4 (8%) patients had non-union. Mean duration for achieving union was 163 + 30.6 days. Interlocking screws were broken in 2 patients while no nail was broken in any patient. Intramedullary interlocking nailing is an effective measure in treating closed and grade I and II open tibial fractures. It provides a high rate of union less complications and early return to function.

  1. Prosthetic replacement for proximal humeral fractures.

    PubMed

    Kontakis, George; Tosounidis, Theodoros; Galanakis, Ioannis; Megas, Panagiotis

    2008-12-01

    The ideal management of complex proximal humeral fractures continues to be debatable. Evolution of proximal humeral fracture management, during the past decade, led to the implementation of many innovations in surgical treatment. Even though the pendulum of treatment seems to swing towards new trends such as locked plating, hemiarthroplasty remains a valid and reliable option that serves the patient's needs well. Hemiarthroplasty is indicated for complex proximal humeral fractures in elderly patients with poor bone stock and when internal fixation is difficult or unreliable. Hemiarthroplasty provides a better result when it is performed early post-injury. Stem height, retroversion and tuberosity positioning are technical aspects of utmost importance. Additionally reverse total shoulder arthroplasty is an alternative new modality that can be used as a primary solution in selected patients with proximal humeral fracture treatment. Failed hemiarthroplasty and fracture sequelae can be successfully managed with reverse total shoulder arthroplasty. Individual decision-making and tailored treatment that takes into consideration the personality of the fracture and the patient's characteristics should be used.

  2. Distal tibial pilon fractures (AO/OTA type B, and C) treated with the external skeletal and minimal internal fixation method.

    PubMed

    Milenković, Sasa; Mitković, Milorad; Micić, Ivan; Mladenović, Desimir; Najman, Stevo; Trajanović, Miroslav; Manić, Miodrag; Mitković, Milan

    2013-09-01

    Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF) and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60) years. The average follow-up was 21.86 (from 12 to 48) months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20) weeks. There were 4 (12.19%) infections around the pins of the external skeletal fixator and one (3.22%) deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90%) patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for treating all types of inta-articular pilon fractures. In

  3. Total knee arthroplasty in patients with a prior fracture of the tibial plateau.

    PubMed

    Weiss, Nicholas G; Parvizi, Javad; Trousdale, Robert T; Bryce, Rex D; Lewallen, David G

    2003-02-01

    A fracture of the tibial plateau may predispose the knee to the development of posttraumatic arthritis. Malunion, intra-articular chondro-osseous defects, limb malalignment, retained internal fixation devices, and poor surrounding soft tissues may in turn compromise the outcome of total knee arthroplasty. The aim of our study was to evaluate the results of total knee arthroplasty in patients with a previous fracture of the tibial plateau. The results of sixty-two condylar total knee arthroplasties performed with cement, from 1988 to 1999, in sixty-two patients with a previous fracture of the tibial plateau were reviewed. The fracture of the tibial plateau had been treated by open reduction and internal fixation in thirty-eight knees, external fixation in one knee, and nonoperatively in twenty-three knees. There were forty women and twenty-two men with an average age of sixty-three years at the time of the arthroplasty. Knee Society scores were recorded preoperatively and at the time of follow-up, at an average of 4.7 years, and complications were noted. No patient was lost to follow-up. The mean Knee Society scores improved significantly (p < 0.0001), from 43.9 points for pain and 52 points for function preoperatively to 82.9 and 84 points, respectively, at the time of the latest follow-up. There were thirteen reoperations, which included manipulation with the patient under anesthesia (five knees), wound revision (three knees), and component revision (five knees). There were six intraoperative complications (10%). A postoperative complication occurred in sixteen knees (26%). The vast majority of patients treated with total knee arthroplasty after a previous fracture of the tibial plateau have substantial improvement in function and relief of pain. However, these patients are at increased risk for perioperative complications, as evidenced by the high reoperation rate of 21% in this study.

  4. Role of the fibula in the stability of diaphyseal tibial fractures fixed by intramedullary nailing.

    PubMed

    Galbraith, John G; Daly, Charles J; Harty, James A; Dailey, Hannah L

    2016-10-01

    For tibial fractures, the decision to fix a concomitant fibular fracture is undertaken on a case-by-case basis. To aid in this clinical decision-making process, we investigated whether loss of integrity of the fibula significantly destabilises midshaft tibial fractures, whether fixation of the fibula restores stability to the tibia, and whether removal of the fibula and interosseous membrane for expediency in biomechanical testing significantly influences tibial interfragmentary mechanics. Tibia/fibula pairs were harvested from six cadaveric donors with the interosseous membrane intact. A tibial osteotomy fracture was fixed by reamed intramedullary (IM) nailing. Axial, torsion, bending, and shear tests were completed for four models of fibular involvement: intact fibula, osteotomy fracture, fibular plating, and resected fibula and interosseous membrane. Overall construct stiffness decreased slightly with fibular osteotomy compared to intact bone, but this change was not statistically significant. Under low loads, the influence of the fibula on construct stability was only statistically significant in torsion (large effect size). Fibular plating stiffened the construct slightly, but this change was not statistically significant compared to the fibular osteotomy case. Complete resection of the fibula and interosseous membrane significantly decreased construct torsional stiffness only (large effect size). These results suggest that fixation of the fibula may not contribute significantly to the stability of diaphyseal tibial fractures and should not be undertaken unless otherwise clinically indicated. For testing purposes, load-sharing through the interosseous membrane contributes significantly to overall construct mechanics, especially in torsion, and we recommend preservation of these structures when possible. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation

    PubMed Central

    Simon, A.-L.; Apostolou, N.; Vidal, C.; Ferrero, E.; Mazda, K.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. Methods All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. Results A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. Conclusions This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. Level of Evidence IV PMID:29456750

  6. Evaluation and management of pediatric proximal humerus fractures.

    PubMed

    Popkin, Charles A; Levine, William N; Ahmad, Christopher S

    2015-02-01

    In the pediatric population, sports participation, falls, and motor vehicle accidents can result in proximal humerus fractures. Because the proximal humeral growth plate is responsible for up to 80% of the growth of the humerus, the remodeling of these fractures in children is tremendous. Most of these injuries can be treated with a sling or hanging arm cast, although older children with decreased remodeling capacity may require surgery. Special considerations should be taken for management of proximal humerus fractures that occur in the context of Little League shoulder, lesser tuerosity avulsion fractures, fracture-dislocations, birth fractures, and fractures associated with cysts. Most pediatric patients with proximal humerus fractures have favorable results, and complications are infrequent. Copyright 2015 by the American Academy of Orthopaedic Surgeons.

  7. Free flap reconstructions of tibial fractures complicated after internal fixation.

    PubMed

    Nieminen, H; Kuokkanen, H; Tukiainen, E; Asko-Seljavaara, S

    1995-04-01

    The cases of 15 patients are presented where microvascular soft-tissue reconstructions became necessary after internal fixation of tibial fractures. Primarily, seven of the fractures were closed. Eleven fractures had originally been treated by open reduction and internal fixation using plates and screws, and four by intramedullary nailing. All of the patients suffered from postoperative complications leading to exposure of the bone or fixation material. The internal fixation material was removed and radical revision of dead and infected tissue was carried out in all cases. Soft tissue reconstruction was performed using a free microvascular muscle flap (11 latissimus dorsi, three rectus abdominis, and one gracilis). In eight cases the nonunion of the fracture indicated external fixation. The microvascular reconstruction was successful in all 15 patients. In one case the recurrence of deep infection finally indicated a below-knee amputation. In another case, chronic infection with fistulation recurred postoperatively. After a mean follow-up of 26 months the soft tissue coverage was good in all the remaining 13 cases. All the fractures united. Microvascular free muscle flap reconstruction of the leg is regarded as a reliable method for salvaging legs with large soft-tissue defects or defects in the distal leg. If after internal fixation of the tibial fracture the osteosynthesis material or fracture is exposed, reconstruction of the soft-tissue can successfully be performed by free flap transfer. By radical revision, external fixation, bone grafting, and a free flap the healing of the fracture can be achieved.

  8. Adult periarticular locking plates for the treatment of pediatric and adolescent subtrochanteric hip fractures.

    PubMed

    Sanders, Samuel; Egol, Kenneth A

    2009-01-01

    Two cases are presented in which adult, precontoured, lower-extremity periarticular locking plates were utilized for fixation of subtrochanteric femur fractures in pediatric patients. Recognition of the fact that a distal tibial locking plate in a small child and a proximal tibial locking plate in an adolescent anatomically ft the proximal femur in each case may provide a surgeon treating subtrochanteric hip fractures in this population increased options for operative stabilization.

  9. Low-energy fracture of posterolateral tibial plateau: treatment by a posterolateral prone approach.

    PubMed

    Yu, Guang-Rong; Xia, Jiang; Zhou, Jia-Qian; Yang, Yun-Feng

    2012-05-01

    Most of the posterolateral tibial plateau fractures are caused by low-energy injury. The posterior fracture fragment could not be exposed and reduced well through traditional approaches. The aim of this study was to review the results of surgical treatment of this kind of fracture using posterolateral approach with patient in prone position. The low-energy posterolateral fracture is defined as the main part of articular depression or split fragment limited within the posterior half of the lateral column. Direct reduction and buttress plate fixation through the posterolateral prone approach was applied in all the patients. In our series, 15 of 132 (11.4%) patients with tibial plateau fractures were identified as low-energy posterolateral fractures. The clinical outcomes were available in 14 of the 15 patients through phone interviews and chart reviews. Mean follow-up was 35.1 months (range: 24-48 months). All the patients had anatomic or good reductions (≤ 2 mm step/gap). Average range of motion was 0.7 degrees to 123.2 degrees (5-110 degrees to 0-140 degrees). The complications were limited to one superficial wound infection, two slight flexion contractures, and five implants removal. The average modified hospital for special surgery knee score was 93.4 (range: 86-100). The posterolateral prone approach provides excellent visualization, which can facilitate the reduction and posterior buttress plate fixation for low-energy posterolateral tibial plateau fractures and shows encouraging results. V, therapeutic study.

  10. Anthropometric measurements of tibial plateau and correlation with the current tibial implants.

    PubMed

    Erkocak, Omer Faruk; Kucukdurmaz, Fatih; Sayar, Safak; Erdil, Mehmet Emin; Ceylan, Hasan Huseyin; Tuncay, Ibrahim

    2016-09-01

    The aim of the study was to make an anthropometric analysis at the resected surfaces of the proximal tibia in the Turkish population and to compare the data with the dimensions of tibial components in current use. We hypothesized that tibial components currently available on the market do not fulfil the requirements of this population and a new tibial component design may be required, especially for female patients with small stature. Anthropometric data from the proximal tibia of 226 knees in 226 Turkish subjects were measured using magnetic resonance imaging. We measured the mediolateral, middle anteroposterior, medial and lateral anteroposterior dimensions and the aspect ratio of the resected proximal tibial surface. All morphological data were compared with the dimensions of five contemporary tibial implants, including asymmetric and symmetric design types. The dimensions of the tibial plateau of Turkish knees demonstrated significant differences according to gender (P < 0.05). Among the different tibial implants reviewed, neither asymmetric nor symmetric designs exhibited a perfect conformity to proximal tibial morphology in size and shape. The vast majority of tibial implants involved in this study tend to overhang anteroposteriorly, and a statistically significant number of women (21 %, P < 0.05) had tibial anteroposterior diameters smaller than the smallest available tibial component. Tibial components designed according to anthropometric measurements of Western populations do not perfectly meet the requirements of Turkish population. These data could provide the basis for designing the optimal and smaller tibial component for this population, especially for women, is required for best fit. II.

  11. The anterior tilt angle of the proximal tibia epiphyseal plate: a significant radiological finding in young children with trampoline fractures.

    PubMed

    Stranzinger, Enno; Leidolt, Lars; Eich, Georg; Klimek, Peter Michael

    2014-08-01

    Evaluation of the anterior tilt angle of the proximal tibia epiphyseal plate in young children, which suffered a trampoline fracture in comparison with a normal population. 62 children (31 females, 31 males) between 2 and 5 years of age (average 2 years 11 months, standard deviation 11 months) with radiographs in two views of the tibia were included in this retrospective study. 25 children with proximal tibia fractures were injured with a history of jumping on a trampoline. All other causes for tibia fractures were excluded. A normal age-mapped control cohort of 37 children was compared. These children had neither evidence of a trampoline related injury nor a fracture of the tibia. The anterior tilt angle of the epiphyseal plate of the tibia was defined as an angle between the proximal tibia physis and the distal tibia physis on a lateral view. Two radiologists evaluated all radiographs for fractures and measured the anterior tilt angle in consensus. An unpaired Student's t-test was used for statistical analysis (SPSS). Original reports were reviewed and compared with the radiological findings and follow-up radiographs. In the normal control group, the average anterior tilt angle measured -3.2°, SD ± 2.8°. The children with trampoline fractures showed an anterior tilt of +4.4°, SD ± 2.9°. The difference was statistically significant, P<0.0001. In 6 patients (24% of all patients with confirmed fractures) the original report missed to diagnose the proximal tibial fracture. Young children between 2 and 5 years of age are at risk for proximal tibia fractures while jumping on a trampoline. These fractures may be very subtle and difficult to detect on initial radiographs. Measurement of the anterior tilt angle of the proximal tibia epiphyseal plate on lateral radiographs is supportive for interpreting correctly trampoline fractures. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  12. Risk of total knee arthroplasty after operatively treated tibial plateau fracture: a matched-population-based cohort study.

    PubMed

    Wasserstein, David; Henry, Patrick; Paterson, J Michael; Kreder, Hans J; Jenkinson, Richard

    2014-01-15

    The aims of operative treatment of displaced tibial plateau fractures are to stabilize the injured knee to restore optimal function and to minimize the risk of posttraumatic arthritis and the eventual need for total knee arthroplasty. The purpose of our study was to define the rate of subsequent total knee arthroplasty after tibial plateau fractures in a large cohort and to compare that rate with the rate in the general population. All patients sixteen years of age or older who had undergone surgical treatment of a tibial plateau fracture from 1996 to 2009 in the province of Ontario, Canada, were identified from administrative health databases with use of surgeon fee codes. Each member of the tibial plateau fracture cohort was matched to four individuals from the general population according to age, sex, income, and urban/rural residence. The rates of total knee arthroplasty at two, five, and ten years were compared by using time-to-event analysis. A separate Cox proportional hazards model was used to explore the influence of patient, provider, and surgical factors on the time to total knee arthroplasty. We identified 8426 patients (48.5% female; median age, 48.9 years) who had undergone fixation of a tibial plateau fracture and matched them to 33,698 controls. The two, five, and ten-year rates of total knee arthroplasty in the plateau fracture and control cohorts were 0.32% versus 0.29%, 5.3% versus 0.82%, and 7.3% versus 1.8%, respectively (p < 0.0001). After adjustment for comorbidity, plateau fracture surgery was found to significantly increase the likelihood of total knee arthroplasty (hazard ratio [HR], 5.29 [95% confidence interval, 4.58, 6.11]; p < 0.0001). Higher rates of total knee arthroplasty were also associated with increasing age (HR, 1.03 [1.03, 1.04] per year over the age of forty-eight; p < 0.0001), bicondylar fracture (HR, 1.53 [1.26, 1.84]; p < 0.0001), and greater comorbidity (HR, 2.17 [1.70, 2.77]; p < 0.001). Ten years after tibial plateau

  13. Appropriate hinge position for prevention of unstable lateral hinge fracture in open wedge high tibial osteotomy.

    PubMed

    Nakamura, R; Komatsu, N; Fujita, K; Kuroda, K; Takahashi, M; Omi, R; Katsuki, Y; Tsuchiya, H

    2017-10-01

    Open wedge high tibial osteotomy (OWHTO) for medial-compartment osteoarthritis of the knee can be complicated by intra-operative lateral hinge fracture (LHF). We aimed to establish the relationship between hinge position and fracture types, and suggest an appropriate hinge position to reduce the risk of this complication. Consecutive patients undergoing OWHTO were evaluated on coronal multiplanar reconstruction CT images. Hinge positions were divided into five zones in our new classification, by their relationship to the proximal tibiofibular joint (PTFJ). Fractures were classified into types I, II, and III according to the Takeuchi classification. Among 111 patients undergoing OWHTOs, 22 sustained lateral hinge fractures. Of the 89 patients without fractures, 70 had hinges in the zone within the PTFJ and lateral to the medial margin of the PTFJ (zone WL), just above the PTFJ. Among the five zones, the relative risk of unstable fracture was significantly lower in zone WL (relative risk 0.24, confidence interval 0.17 to 0.34). Zone WL appears to offer the safest position for the placement of the osteotomy hinge when trying to avoid a fracture at the osteotomy site. Cite this article: Bone Joint J 2017;99B10:1313-18. ©2017 The British Editorial Society of Bone & Joint Surgery.

  14. Symptomatic venous thromboembolism following circular frame treatment for tibial fractures.

    PubMed

    Vollans, S; Chaturvedi, A; Sivasankaran, K; Madhu, T; Hadland, Y; Allgar, V; Sharma, H K

    2015-01-01

    Venous thromboembolism (VTE) is a significant cause of morbidity and mortality following tibial fractures. The risk is as high as 77% without prophylaxis and around 10% with prophylaxis. Within the current literature there are no figures reported specifically for those individuals treated with circular frames. Our aim was to evaluate the VTE incidence within a single surgeon series and to evaluate potential risk factors. We retrospectively reviewed our consecutive single surgeon series of 177 patients admitted to a major trauma unit with tibial fractures. All patients received standardised care, including chemical thromboprophylaxis within 24h of injury until independent mobility was achieved. We comprehensively reviewed our prospective database and medical records looking at demographics and potential risk factors. Seven patients (4.0% ± 2.87%) developed symptomatic VTE during the course of frame treatment; three deep vein thrombosis (DVTs) and four pulmonary embolisms (PEs). Those with a VTE event had significantly increased body mass index (BMI) (p = 0.01) when compared to those without symptomatic VTE. No differences (p > 0.05) were observed between the groups in age, gender, smoking status, fracture type (anatomical allocation or open/closed), delay to frame treatment, weight bearing status post-frame, inpatient stay or total duration of frame treatment. This study suggests that increased BMI is a statistically significant risk factor for VTE, as reported in current literature. In addition, we calculated the true risk of VTE following circular frame treatment for tibial fracture in our series is from 1.13% to 6.87%, which is at least comparable to other forms of treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Individual risk factors for deep infection and compromised fracture healing after intramedullary nailing of tibial shaft fractures: a single centre experience of 480 patients.

    PubMed

    Metsemakers, W-J; Handojo, K; Reynders, P; Sermon, A; Vanderschot, P; Nijs, S

    2015-04-01

    Despite modern advances in the treatment of tibial shaft fractures, complications including nonunion, malunion, and infection remain relatively frequent. A better understanding of these injuries and its complications could lead to prevention rather than treatment strategies. A retrospective study was performed to identify risk factors for deep infection and compromised fracture healing after intramedullary nailing (IMN) of tibial shaft fractures. Between January 2000 and January 2012, 480 consecutive patients with 486 tibial shaft fractures were enrolled in the study. Statistical analysis was performed to determine predictors of deep infection and compromised fracture healing. Compromised fracture healing was subdivided in delayed union and nonunion. The following independent variables were selected for analysis: age, sex, smoking, obesity, diabetes, American Society of Anaesthesiologists (ASA) classification, polytrauma, fracture type, open fractures, Gustilo type, primary external fixation (EF), time to nailing (TTN) and reaming. As primary statistical evaluation we performed a univariate analysis, followed by a multiple logistic regression model. Univariate regression analysis revealed similar risk factors for delayed union and nonunion, including fracture type, open fractures and Gustilo type. Factors affecting the occurrence of deep infection in this model were primary EF, a prolonged TTN, open fractures and Gustilo type. Multiple logistic regression analysis revealed polytrauma as the single risk factor for nonunion. With respect to delayed union, no risk factors could be identified. In the same statistical model, deep infection was correlated with primary EF. The purpose of this study was to evaluate risk factors of poor outcome after IMN of tibial shaft fractures. The univariate regression analysis showed that the nature of complications after tibial shaft nailing could be multifactorial. This was not confirmed in a multiple logistic regression model, which

  16. The Impact of Computed Tomography on Decision Making in Tibial Plateau Fractures.

    PubMed

    Castiglia, Marcello Teixeira; Nogueira-Barbosa, Marcello Henrique; Messias, Andre Marcio Vieira; Salim, Rodrigo; Fogagnolo, Fabricio; Schatzker, Joseph; Kfuri, Mauricio

    2018-02-14

    Schatzker introduced one of the most used classification systems for tibial plateau fractures, based on plain radiographs. Computed tomography brought to attention the importance of coronal plane-oriented fractures. The goal of our study was to determine if the addition of computed tomography would affect the decision making of surgeons who usually use the Schatzker classification to assess tibial plateau fractures. Image studies of 70 patients who sustained tibial plateau fractures were uploaded to a dedicated homepage. Every patient was linked to a folder which contained two radiographic projections (anteroposterior and lateral), three interactive videos of computed tomography (axial, sagittal, and coronal), and eight pictures depicting tridimensional reconstructions of the tibial plateau. Ten attending orthopaedic surgeons, who were blinded to the cases, were granted access to the homepage and assessed each set of images in two different rounds, separated to each other by an interval of 2 weeks. Each case was evaluated in three steps, where surgeons had access, respectively to radiographs, two-dimensional videos of computed tomography, and three-dimensional reconstruction images. After every step, surgeons were asked to present how would they classify the case using the Schatzker system and which surgical approaches would be appropriate. We evaluated the inter- and intraobserver reliability of the Schatzker classification using the Kappa concordance coefficient, as well as the impact of computed tomography in the decision making regarding the surgical approach for each case, by using the chi-square test and likelihood ratio. The interobserver concordance kappa coefficients after each assessment step were, respectively, 0.58, 0.62, and 0.64. For the intraobserver analysis, the coefficients were, respectively, 0.76, 0.75, and 0.78. Computed tomography changed the surgical approach selection for the types II, V, and VI of Schatzker ( p  < 0.01). The addition of

  17. Tension Band Plating for Chronic Anterior Tibial Stress Fractures in High-Performance Athletes.

    PubMed

    Zbeda, Robert M; Sculco, Peter K; Urch, Ekaterina Y; Lazaro, Lionel E; Borens, Olivier; Williams, Riley J; Lorich, Dean G; Wellman, David S; Helfet, David L

    2015-07-01

    Anterior tibial stress fractures are associated with high rates of delayed union and nonunion, which can be particularly devastating to a professional athlete who requires rapid return to competition. Current surgical treatment strategies include intramedullary nailing, which has satisfactory rates of fracture union but an associated risk of anterior knee pain. Anterior tension band plating is a biomechanically sound alternative treatment for these fractures. Tension band plating of chronic anterior tibial stress fractures leads to rapid healing and return to physical activity and avoids the anterior knee pain associated with intramedullary nailing. Case series; Level of evidence, 4. Between 2001 and 2013, there were 13 chronic anterior tibial stress fractures in 12 professional or collegiate athletes who underwent tension band plating after failing nonoperative management. Patient charts were retrospectively reviewed for demographics, injury history, and surgical details. Radiographs were used to assess time to osseous union. Follow-up notes and phone interviews were used to determine follow-up time, return to training time, and whether the patient was able to return to competition. Cases included 13 stress fractures in 12 patients (9 females, 3 males). Five patients were track-and-field athletes, 4 patients played basketball, 2 patients played volleyball, and 1 was a ballet dancer. Five patients were Division I collegiate athletes and 7 were professional or Olympic athletes. Average age at time of surgery was 23.6 years (range, 20-32 years). Osseous union occurred on average at 9.6 weeks (range, 5.3-16.9 weeks) after surgery. Patients returned to training on average at 11.1 weeks (range, 5.7-20 weeks). Ninety-two percent (12/13) eventually returned to preinjury competition levels. Thirty-eight percent (5/13) underwent removal of hardware for plate prominence. There was no incidence of infection or nonunion. Anterior tension band plating for chronic tibial stress

  18. ß-TCP bone substitutes in tibial plateau depression fractures.

    PubMed

    Rolvien, Tim; Barvencik, Florian; Klatte, Till Orla; Busse, Björn; Hahn, Michael; Rueger, Johannes Maria; Rupprecht, Martin

    2017-10-01

    The use of beta-tricalciumphospate (ß-TCP, Cerasorb®) ceramics as an alternative for autologous bone-grafting has been outlined previously, however with no study focusing on both clinical and histological outcomes of ß-TCP application in patients with multi-fragment tibial plateau fractures. The aim of this study was to analyze the long-term results of ß-TCP in patients with tibial plateau fractures. 52 patients were included in this study. All patients underwent open surgery with ß-TCP block or granulate application. After a mean follow-up of 36months (14-64months), the patients were reviewed. Radiography and computed-tomography were performed, while the Rasmussen score was obtained for clinical outcome. Furthermore, seven patients underwent biopsy during hardware removal, which was subsequently analyzed by histology and backscattered electron microscopy (BSEM). An excellent reduction with two millimeters or less of residual incongruity was achieved in 83% of the patients. At follow-up, no further changes occurred and no nonunions were observed. Functional outcome was good to excellent in 82%. Four patients underwent revision surgery due to reasons unrelated to the bone substitute material. Histologic analyses indicated that new bone was built around the ß-TCP-grafts, however a complete resorption of ß-TCP was not observed. ß-TCP combined with internal fixation represents an effective and safe treatment of tibial plateau depression fractures with good functional recovery. While its osteoconductivity seems to be successful, the biological degradation and replacement of ß-TCP is less pronounced in humans than previous animal studies have indicated. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Return to sport following tibial plateau fractures: A systematic review

    PubMed Central

    Robertson, Greg A J; Wong, Seng J; Wood, Alexander M

    2017-01-01

    AIM To systemically review all studies reporting return to sport following tibial plateau fracture, in order to provide information on return rates and times to sport, and to assess variations in sporting outcome for different treatment methods. METHODS A systematic search of CINAHAL, Cochrane, EMBASE, Google Scholar, MEDLINE, PEDro, Scopus, SPORTDiscus and Web of Science was performed in January 2017 using the keywords “tibial”, “plateau”, “fractures”, “knee”, “athletes”, “sports”, “non-operative”, “conservative”, “operative”, “return to sport”. All studies which recorded return rates and times to sport following tibial plateau fractures were included. RESULTS Twenty-seven studies were included: 1 was a randomised controlled trial, 7 were prospective cohort studies, 16 were retrospective cohort studies, 3 were case series. One study reported on the outcome of conservative management (n = 3); 27 reported on the outcome of surgical management (n = 917). Nine studies reported on Open Reduction Internal Fixation (ORIF) (n = 193), 11 on Arthroscopic-Assisted Reduction Internal Fixation (ARIF) (n = 253) and 7 on Frame-Assisted Fixation (FRAME) (n = 262). All studies recorded “return to sport” rates. Only one study recorded a “return to sport” time. The return rate to sport for the total cohort was 70%. For the conservatively-managed fractures, the return rate was 100%. For the surgically-managed fractures, the return rate was 70%. For fractures managed with ORIF, the return rate was 60%. For fractures managed with ARIF, the return rate was 83%. For fractures managed with FRAME was 52%. The return rate for ARIF was found to be significantly greater than that for ORIF (OR 3.22, 95%CI: 2.09-4.97, P < 0.001) and for FRAME (OR 4.33, 95%CI: 2.89-6.50, P < 0.001). No difference was found between the return rates for ORIF and FRAME (OR 1.35, 95%CI: 0.92-1.96, P = 0.122). The recorded return time was 6.9 mo (median), from a study

  20. The effect of proximal tibial slope on dynamic stability testing of the posterior cruciate ligament- and posterolateral corner-deficient knee.

    PubMed

    Petrigliano, Frank A; Suero, Eduardo M; Voos, James E; Pearle, Andrew D; Allen, Answorth A

    2012-06-01

    Proximal tibial slope has been shown to influence anteroposterior translation and tibial resting point in the posterior cruciate ligament (PCL)-deficient knee. The effect of proximal tibial slope on rotational stability of the knee is unknown. Change in proximal tibial slope produced via osteotomy can influence both static translation and dynamic rotational kinematics in the PCL/posterolateral corner (PLC)-deficient knee. Controlled laboratory study. Posterior drawer, dial, and mechanized reverse pivot-shift (RPS) tests were performed on hip-to-toe specimens and translation of the lateral and medial compartments measured utilizing navigation (n = 10). The PCL and structures of the PLC were then sectioned. Stability testing was repeated, and compartmental translation was recorded. A proximal tibial osteotomy in the sagittal plane was then performed achieving either +5° or -5° of tibial slope variation, after which stability testing was repeated (n = 10). Analysis was performed using 1-way analysis of variance (ANOVA; α = .05). Combined sectioning of the PCL and PLC structures resulted in a 10.5-mm increase in the posterior drawer, 15.5-mm increase in the dial test at 30°, 14.5-mm increase in the dial test at 90°, and 17.9-mm increase in the RPS (vs intact; P < .05). Increasing the posterior slope (high tibial osteotomy [HTO] +5°) in the PCL/PLC-deficient knee reduced medial compartment translation by 3.3 mm during posterior drawer (vs deficient; P < .05) but had no significant effect on the dial test at 30°, dial test at 90°, or RPS. Conversely, reversing the slope (HTO -5°) caused a 4.8-mm increase in medial compartment translation (vs deficient state; P < .05) during posterior drawer and an 8.6-mm increase in lateral compartment translation and 9.0-mm increase in medial compartment translation during RPS (vs deficient state; P < .05). Increasing posterior tibial slope diminished static posterior instability of the PCL/PLC-deficient knee as measured by the

  1. Minimal internal fixation augmented by small wire transfixion frames for high-energy tibial plateau fractures.

    PubMed

    Katsenis, Dimitris; Athanasiou, Vasilis; Vasilis, Athanasiou; Megas, Panayiotis; Panayiotis, Megas; Tyllianakis, Minos; Minos, Tillianakis; Lambiris, Elias

    2005-04-01

    To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.

  2. The Valgus Inclination of the Tibial Component Increases the Risk of Medial Tibial Condylar Fractures in Unicompartmental Knee Arthroplasty.

    PubMed

    Inoue, Shinji; Akagi, Masao; Asada, Shigeki; Mori, Shigeshi; Zaima, Hironori; Hashida, Masahiko

    2016-09-01

    Medial tibial condylar fractures (MTCFs) are a rare but serious complication after unicompartmental knee arthroplasty. Although some surgical pitfalls have been reported for MTCFs, it is not clear whether the varus/valgus tibial inclination contributes to the risk of MTCFs. We constructed a 3-dimensional finite elemental method model of the tibia with a medial component and assessed stress concentrations by changing the inclination from 6° varus to 6° valgus. Subsequently, we repeated the same procedure adding extended sagittal bone cuts of 2° and 10° in the posterior tibial cortex. Furthermore, we calculated the bone volume that supported the tibial component, which is considered to affect stress distribution in the medial tibial condyle. Stress concentrations were observed on the medial tibial metaphyseal cortices and on the anterior and posterior tibial cortices in the corner of cut surfaces in all models; moreover, the maximum principal stresses on the posterior cortex were larger than those on the anterior cortex. The extended sagittal bone cuts in the posterior tibial cortex increased the stresses further at these 3 sites. In the models with a 10° extended sagittal bone cut, the maximum principal stress on the posterior cortex increased as the tibial inclination changed from 6° varus to 6° valgus. The bone volume decreased as the inclination changed from varus to valgus. In this finite element method, the risk of MTCFs increases with increasing valgus inclination of the tibial component and with increased extension of the sagittal cut in the posterior tibial cortex. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.

    PubMed

    Weninger, Patrick; Schueller, Michael; Jamek, Michael; Stanzl-Tschegg, Stefanie; Redl, Heinz; Tschegg, Elmar K

    2009-05-01

    Unreamed tibia nails with small diameters are increasingly used for fracture fixation. However, little is known about the fatigue strength of proximal and distal interlocking screws in those nails. To date, no data are available reporting on mechanical differences of solid compared to cannulated tibial nails. The aim of this study was to assess the fatigue strength of proximal and distal interlocking screws of solid and cannulated small diameter tibia nails. We created a distal tibia fracture model (AO/OTA 43 A3) using 16 Sawbones. After fracture stabilization with one of four different nail types (Expert Tibial Nail, VersaNail, T2 Tibial Nailing System, Connex), mechanical testing was performed in three loading series (40,000 cycles each) with incremental loads. Timing and type of interlocking screw failure were assessed. Interlocking screw failure was observed significantly earlier (after a mean interval of 57,042 cycles) in cannulated tibial nails (VersaNail, T2) compared to solid nails (after a mean interval of 88,415 cycles; P < 0.001). Proximal interlocking screw failure was recorded if oblique screws were used proximally (VersaNail, T2, Connex). No distal interlocking screw failure was recorded in the Connex nail. Two- and three-part fractures of proximal or distal interlocking screws were observed in all specimen. Proximal and distal interlocking screw failure has to be considered in small diameter nails in case of delayed fracture healing. To support our results, further experimental studies and clinical series are necessary.

  4. Dynamic osteosynthesis by modified Kuntscher nail for the treatment of tibial diaphyseal fractures.

    PubMed

    Gadegone, Wasudeo M; Salphale, Yogesh S

    2009-04-01

    We evaluated a series of diaphyseal fractures of the tibia using low-cost, Indian-made modified Kuntscher nail (Daga nail) with the provision of distal locking screw for the management of the tibial diaphyseal fractures. One hundred and fifty one consecutive patients with diaphyseal fractures of tibia with 151 fractures who were treated by Daga nail were enrolled. One of the patients who had died because of cancer, and the two patients who were lost to follow-up at 3 months were excluded from the study.Therefore data of 148 patients with one hundred and fortyeight fractures is described. One hundred twenty closed fractures, 20 open Grade I fractures, and eight open Grade II fractures as per Gustilo and Anderson classification were included in this study. One hundred fourteen men and 34 women, with a mean age of 38.4 years, were studied. The result were analysed for Surgical time, duration of hospitalisation, union time, union rate, complication rate, functional recovery and crutch walking time. The fractures were followed at least until the time of solid union. The follow-up period averaged 15 months (range, 6-26 months). Union occurred in 140 cases (94.6%). The mean time to union was 13 weeks for closed fractures,17.8 weeks for Grade I open fractures, and 21.6 weeks for Grade II open fractures. Compartment syndrome occurred in two patients. Superficial infection occurred in five cases of Grade I and II compound fractures. Three closed fractures and one case of Grade I compound fracture required bone grafting for delayed union. Two cases of Grade II compound fracture with nonunion required revision surgery and bone grafting. Twelve cases resulted in acceptable malalignment due to operative technical error. In four cases, the distal screw breakage was seen, but none of these complications interfered with fracture healing. Recovery of joint motion was essentially normal in those patients without knee or ankle injury. Unreamed distally locked dynamic tibial nailing

  5. A Biomechanical Study of Posteromedial Tibial Plateau Fracture Stability: Do They All Require Fixation?

    PubMed

    Cuéllar, Vanessa G; Martinez, Danny; Immerman, Igor; Oh, Cheongeun; Walker, Peter S; Egol, Kenneth A

    2015-07-01

    Although the posteromedial fragment in tibial plateau fractures is often considered unstable, biomechanical evidence supporting this view is lacking. We aimed to evaluate the stability of the fragment in a cadaver model. Our hypothesis was that under the expected small axial force during rehabilitation and the combined effects of this force with shear force, internal rotation torque, and varus moment, the most common posteromedial tibial fragment morphology could maintain stability in early flexion. Axial compression force alone or combined with posterior shear, internal rotation torque, or varus moment was applied to the femurs of 5 fresh cadaveric knees. A Tekscan pressure mapping system was used to measure pressure and contact area between the femoral condyles, meniscus, and tibial plateau. A Microscribe 3D digitizer was used to define the 3-dimensional positions of the femur and tibia. A 10-mm and then a 20-mm osteotomy was created with a saw at an angle of 30 degrees in the axial plane with respect to the tangent of the posterior tibial plateau and 75 degrees in the sagittal plane, representing a typical posteromedial fracture fragment. At each flexion angle (15, 30, 60, 90, and 120 degrees) and loading condition (axial compression only, compression with shear force, torque, and varus moment), distal displacement of the medial femoral condyle and the tibial fracture fragments was determined. For the 10-mm fragment, medial femoral condyle displacement was little affected up to approximately 30-degree flexion, after which it increased. For the 20-mm fragment, there was progressive medial femoral condyle displacement with increasing flexion from baseline. However, for the 10- and 20-mm fragments themselves, displacements were noted at every flexion angle, starting at 1.7 mm inferior displacement with 15 degrees of flexion and internal rotation torque and up to 10.2 mm displacement with 90 degrees of flexion and varus bending moment. In this cadaveric model of a

  6. Moore I postero-medial articular tibial fracture in alpine skiers: Surgical management and return to sports activity.

    PubMed

    Morin, Vincent; Pailhé, Régis; Sharma, Akash; Rouchy, René-Christopher; Cognault, Jérémy; Rubens-Duval, Brice; Saragaglia, Dominique

    2016-06-01

    Over the past 10 years, like many authors, we observed an increasing number of Moore I tibial plateau fractures related to alpine skiing for which the surgeon may face difficult choices regarding surgical approach and fixation means. Some authors have recently been suggesting a posterior approach associated to open reduction and osteosynthesis by a buttress plate. But in our knowledge there is no specific study on sports activity recovery after Moore I tibial fractures. The aim of this work was to assess sports activities and clinical outcomes after surgically treated Moore I tibial plateau fractures in an athletic population of skiers. We conducted a prospective case series between 2012 and 2014. This included fifteen patients aged 39.6±7 years whom presented with a Moore I tibial plateau fracture during a skiing accident. 12 cases (80%) presented with an associated tibial spine fracture. Treatment consisted of a standard antero-medial approach, with a medial para patellar arthrotomy to allow direct visualisation of articular reduction and spinal fixation. Two or three 6.5mm long cancellous bone screws were placed antero-posteriorly so as to ensure perfect compression of the fracture site. Radiological and functional results were assessed by an independent observer (Lysholm-Tegner, UCLA, KOOS scores) at the longest follow-up. Mean follow-up was 18.2±6 months (12-28). An immediate postoperative anatomical reduction was achieved in all cases and remained stable in time. At last follow-up Lysholm mean score was 85±14 points (59-100), UCLA score was 7.3±1.6 (4-10) and Tegner score was 4.6±1.3 (3-6). Mean KOOS score was 77±15 (54-97). 87% of patients had resumed their skiing activity and 93% were satisfied or very satisfied from their post-operative surgical outcome. We observed no pseudarthrosis or secondary varus displacement. In our series 87% of patients had resumed back to their sporting activities. Surgical management of Moore I tibial plateau fractures by

  7. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study.

    PubMed

    Chen, Pengbo; Lu, Hua; Shen, Hao; Wang, Wei; Ni, Binbin; Chen, Jishizhan

    2017-02-23

    Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. Three different 3D finite element models of the lateral tibial plateau fracture with the bone plates were created. Various axial forces (100, 500, 1000, and 1500 N) were applied to simulate the axial compressive load on an adult knee during daily life. The equivalent maps of displacement and stress were output, and relative displacement was calculated along the fracture lines. The displacement and stresses in the fixation complexes increased with the axial force. The equivalent displacement or stress map of each fixation under different axial forces showed similar distributing characteristics. The motion characteristics of the three models differed, and the max-shear stress of trabecula increased with the axial load. These two novel plates could fix lateral tibial plateau fractures involving anterolateral and posterolateral fragments. Motions after open reduction and stable internal fixation should be advised to decrease the risk of trabecular microfracture. The relative displacement of the posterolateral fragments is different when using anterolateral plate and posterolateral plate, which should be considered in choosing the implants for different posterolateral plateau fractures.

  8. Computational comparison of tibial diaphyseal fractures fixed with various degrees of prebending of titanium elastic nails and with and without end caps.

    PubMed

    Chen, Yen-Nien; Lee, Pei-Yuan; Chang, Chih-Han; Chang, Chih-Wei; Ho, Yi-Hung; Li, Chun-Ting; Peng, Yao-Te

    2016-10-01

    Elastic stable intramedullary nailing (ESIN) is a treatment strategy for the management of diaphyseal long-bone fractures in adolescents and children, but few studies have investigated the mechanical stability of tibial diaphyseal fractures treated with various degrees of prebending of the elastic nails. Therefore, the aim of this study was to compare the mechanical stability, including the gap deformation and nail dropping, of a tibia fracture with various fracture sites and fixed with various degrees of prebending of the elastic nails by the finite element method. Furthermore, the contribution of end caps to stability was taken into consideration in the simulation. A tibia model was developed with a transverse fracture at the proximal, middle and distal parts of the diaphysis, and fixed with three degrees of prebending of elastic nails, including those equal to, two times and three times the diameter of the intramedullary canal. The outer diameter of the nail used in the computation was 3.5mm, and the fractured tibia was fixed with two elastic double C-type nails. Furthermore, the proximal end of each nail was set to free or being tied to the surrounding bone by a constraint equation to simulate with or without using end caps. The results indicated that using end caps can prevent the fracture gap from collapsing by stopping the ends of the nails from dropping back in all prebending conditions and fracture patterns, and increasing the prebending of the nails to a degree three times the diameter of the canal reduced the gap shortening and the dropping distance of the nail end in those without using end caps under axial compression and bending. Insufficient prebending of the nails and not using end caps caused the gap to collapse and the nail to drop back at the entry point under loading. Using end caps or increasing the prebending of the nails to three times the diameter of the canal is suggested to stop the nail from dropping back and thus produce a more stable

  9. Delayed Anterior Cruciate Ligament Reconstruction in Young Patients With Previous Anterior Tibial Spine Fractures.

    PubMed

    Mitchell, Justin J; Mayo, Meredith H; Axibal, Derek P; Kasch, Anthony R; Fader, Ryan R; Chadayammuri, Vivek; Terhune, E Bailey; Georgopoulos, Gaia; Rhodes, Jason T; Vidal, Armando F

    2016-08-01

    Avulsion fractures of the anterior tibial spine in young athletes are injuries similar to anterior cruciate ligament (ACL) injuries in adults. Sparse data exist on the association between anterior tibial spine fractures (ATSFs) and later ligamentous laxity or injuries leading to ACL reconstruction. To better delineate the incidence of delayed instability or ACL ruptures requiring delayed ACL reconstruction in young patients with prior fractures of the tibial eminence. Case series; Level of evidence, 4. We identified 101 patients between January 1993 and January 2012 who sustained an ATSF and who met inclusion criteria for this study. All patients had been followed for at least 2 years after the initial injury and were included for analysis after completion of a questionnaire via direct contact, mail, and/or telephone. If patients underwent further surgical intervention and/or underwent later ACL reconstruction, clinical records and operative reports pertaining to these secondary interventions were obtained and reviewed. Differences between categorical variables were assessed using the Fisher exact test. The association between time to revision ACL surgery and fracture type was assessed by Kaplan-Meier plots. The association between need for revision ACL surgery and age, sex, and mechanism of surgery was assessed using logistic regression. Nineteen percent of all patients evaluated underwent delayed ACL reconstruction after a previous tibial spine fracture on the ipsilateral side. While there were a higher proportion of ACL reconstructions in type II fractures, there was not a statistically significant difference in the number of patients within each fracture group who went on to undergo later surgery (P = .29). Further, there was not a significant association between fracture type, sex, or mechanism of injury as it related to the progression to later ACL reconstruction. However, there was a significant association between age at the time of injury and progression

  10. Patient reported health related quality of life early outcomes at 12 months after surgically managed tibial plafond fracture.

    PubMed

    Bonato, Luke J; Edwards, Elton R; Gosling, Cameron McR; Hau, Raphael; Hofstee, Dirk Jan; Shuen, Alex; Gabbe, Belinda J

    2017-04-01

    Tibial plafond fractures represent a small but complex subset of fractures of the lower limb. The aim of this study was to describe the health related quality of life, pain and return to work outcomes 12 months following surgically managed tibial plafond fracture. The Victorian Orthopaedic Trauma Outcomes Registry (VOTOR) database was used to identify patients with tibial plafond fractures. All patients captured by VOTOR with a tibial plafond fracture between September 2003 and July 2009, were identified consecutively and comprised the initial cohort. The radiographs of all identified patients were classified using the AO/OTA fracture classification. A review of the included patient's medical records was performed. Data were collected on the injury event, management and complications. Outcomes at 12 months were prospectively collected by telephone interview and included return to work, a numerical rating scale for assessment of pain and the Short Form 12 (SF-12). There were 98 unilateral tibial plafond fractures; 91 fractures were managed operatively, 4 non-operatively and 3 underwent amputation. The 91 operatively managed patients were the focus of this study. A two-stage management approach, involving temporary external fixation, followed by definitive open reduction and internal fixation, was the most common operative treatment. The follow-up rate at 12 months was 70%. 57% had returned to work by 12 months post-injury, the median (IQR) pain score was 2 (0-5) and 27% reported moderate to severe persistent pain. Mean PCS-12 scores were significantly lower than Australian norms (p=0.99), 38.2 for males and 37.5 for females. The presence of persistent pain, loss of physical health and a low return to work rate highlights the profound impact of tibial plafond fractures on patients' lives. Although this study looked at the early 12 month results, it is expected these outcomes will continue to improve over time. Further studies, with larger patient numbers, must focus

  11. Sports activity after surgical treatment of intra-articular tibial plateau fractures in skiers.

    PubMed

    Loibl, Markus; Bäumlein, Martin; Massen, Felix; Gueorguiev, Boyko; Glaab, Richard; Perren, Thomas; Rillmann, Paavo; Ryf, Christian; Naal, Florian D

    2013-06-01

    Tibial plateau fractures occur frequently while participating in winter sports, but there is no information on whether skiers can resume sports and recreational activities after internal fixation of these fractures. Skiers can resume low-impact sports activity after internal fixation of tibial plateau fractures. Case series; Level of evidence, 4. A total of 103 patients were surveyed by postal questionnaires to determine their sports activities at a mean of 7.8 ± 1.8 years after internal fixation of intra-articular tibial plateau fractures. The survey also included the Lysholm score, the Tegner activity scale, and a visual analog scale (VAS) for pain. At the time of the survey, 88% of the patients were engaged in sports activities (rate of return to sports, 88%), and 53% continued to participate in downhill skiing. The median number of different activities declined from 5 (range, 1-17) preoperatively to 4 (range, 0-11) postoperatively (P < .01). Sports frequency and duration per week did not change: 3 (range, 1-7) preoperatively versus 3 (range, 0-7) postoperatively (P = .275) and 4 hours (range, 1-16 hours) preoperatively versus 3.5 hours (range, 0-15 hours) postoperatively (P = .217), respectively. Median values of all outcome scores declined: Lysholm score, 100 (range, 85-100) preoperatively versus 94.5 (range, 37-100) postoperatively (P < .01); VAS, 0 (range, 0-7) preoperatively versus 1 (range, 0-8) postoperatively (P < .01). Median Tegner activity scale scores declined in all age groups except for patients aged 51 to 60 years. The ability to participate in sports at the time of follow-up compared with the ability before the accident was rated as "similar" by 57 patients (62.0%) and as "worse" by 35 patients (38.0%). The more severe fracture types, B3 and C3 according to the AO classification system, were associated with poorer outcomes related to return to sports and functional scores. A large percentage of skiers with surgically treated intra

  12. Ketorolac Administered in the Recovery Room for Acute Pain Management Does Not Affect Healing Rates of Femoral and Tibial Fractures.

    PubMed

    Donohue, David; Sanders, Drew; Serrano-Riera, Rafa; Jordan, Charles; Gaskins, Roger; Sanders, Roy; Sagi, H Claude

    2016-09-01

    To determine whether ketorolac administered in the immediate perioperative period affects the rate of nonunion in femoral and tibial shaft fractures. Retrospective comparative study. Single Institution, Academic Level 1 Trauma Center. Three hundred and thirteen skeletally mature patients with 137 femoral shaft (OTA 32) and 191 tibial shaft (OTA 42) fractures treated with intramedullary rod fixation. Eighty patients with 33 femoral shaft and 52 tibial shaft fractures were administered ketorolac within the first 24 hours after surgery (group 1-study group). Two-hundred thirty-three patients with 104 femoral shaft and 139 tibial shaft fractures were not (group 2-control group). Rate of reoperation for repair of a nonunion and time to union. Average time to union of the femur was 147 days for group 1 and 159 days for group 2 (P = 0.57). Average time to union of the tibia was 175 days for group 1 and 175 days for group 2 (P = 0.57). There were 3 femoral nonunions (9%) in group 1 and eleven femoral nonunions (11.6%) in group 2 (P = 1.00). There were 3 tibial nonunions (5.8%) in group 1 and 17 tibial nonunions (12.2%) in group 2 (P = 0.29). The average dose of ketorolac for patients who healed their fracture was 85 mg, whereas it was 50 mg for those who did not (P = 0.27). All patients with a nonunion in the study group were current smokers. Ketorolac administered in the first 24 hours after fracture repair for acute pain management does not seem to have a negative impact on time to healing or incidence of nonunion for femoral or tibial shaft fractures. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  13. [Balloon osteoplasty as reduction technique in the treatment of tibial head fractures].

    PubMed

    Freude, T; Kraus, T M; Sandmann, G H

    2015-10-01

    Tibial plateau fractures requiring surgery are severe injuries of the lower extremities. Depending on the fracture pattern, the age of the patient, the range of activity and the bone quality there is a broad variation in adequate treatment.  This article reports on an innovative treatment concept to address split depression fractures (Schatzker type II) and depression fractures (Schatzker type III) of the tibial head using the balloon osteoplasty technique for fracture reduction. Using the balloon technique achieves a precise and safe fracture reduction. This internal osteoplasty combines a minimal invasive percutaneous approach with a gently rise of the depressed area and the associated protection of the stratum regenerativum below the articular cartilage surface. This article lights up the surgical procedure using the balloon technique in tibia depression fractures. Using the balloon technique a precise and safe fracture reduction can be achieved. This internal osteoplasty combines a minimally invasive percutaneous approach with a gentle raising of the depressed area and the associated protection of the regenerative layer below the articular cartilage surface. Fracture reduction by use of a tamper results in high peak forces over small areas, whereas by using the balloon the forces are distributed over a larger area causing less secondary stress to the cartilage tissue. This less invasive approach might help to achieve a better long-term outcome with decreased secondary osteoarthritis due to the precise and chondroprotective reduction technique.

  14. Proximal tibia stress fracture with Osteoarthritis of knee - Radiological and functional analysis of one stage TKA with long stem.

    PubMed

    Soundarrajan, Dhanasekaran; Rajkumar, Natesan; Dhanasekararaja, Palanisamy; Rajasekaran, Shanmuganathan

    2018-01-01

    Proximal tibia stress fractures with knee osteoarthritis pose a challenging situation. We evaluated the radiological and functional outcome of one-stage total knee arthroplasty (TKA) and long stem for patients with varied grades of knee arthritis and proximal tibia stress fractures.  Methods: We analysed 20 patients from April 2012 to March 2017 with proximal tibia stress fractures associated with knee osteoarthritis of varied grades. Out of 20 patients, five were acute fresh fractures. The mean age was 64 years (range, 52-78) which includes three men and 17 women. Previous surgery in the same limb, rheumatoid arthritis, valgus deformity were excluded. All patients were treated with posterior stabilised TKA with long stem, of which, four patients had screw augmentation for medial tibial bone defect and two patients with malunited fracture at stress fracture site required osteotomy, plating and bone grafting. Two patients had two level stress fracture of tibia in the same leg. The mean follow-up period was 28 (range, 6-60) months. The mean tibiofemoral angle improved from 18.27° varus to 1.8° valgus. The mean knee society score improved from 21.9 (range, -10 to 45) to 82.8 (range, 15-99) [p < 0.05]. The mean Knee Society functional score improved from 15.5 (range, -10 to 40) to 76.8 (range, 10-100) [p < 0.05]. All fractures got united at the last follow-up. One patient had infection and wound dehiscence at six months for which debridement done and had poor functional outcome. TKA with long stem gives excellent outcome, irrespective of severity of arthritis associated with stress fracture. By restoring limb alignment and bypassing the fracture site, it facilitates fracture healing. Early detection and prompt intervention is necessary to prevent the progression to recalcitrant non-union or malunion. © The Authors, published by EDP Sciences, 2018.

  15. Management of Gustilo Anderson III B open tibial fractures by primary fascio-septo-cutaneous local flap and primary fixation: The 'fix and shift' technique.

    PubMed

    Ramasamy, P R

    2017-01-01

    Open fractures of tibia have posed great difficulty in managing both the soft tissue and the skeletal components of the injured limb. Gustilo Anderson III B open tibial fractures are more difficult to manage than I, II, and III A fractures. Stable skeletal fixation with immediate soft tissue cover has been the key to the successful outcome in treating open tibial fractures, in particular, Gustilo Anderson III B types. If the length of the open wound is larger and if the exposed surface of tibial fracture and tibial shaft is greater, then the management becomes still more difficult. Thirty six Gustilo Anderson III B open tibial fractures managed between June 2002 and December 2013 with "fix and shift" technique were retrospectively reviewed. All the 36 patients managed by this technique had open wounds measuring >5 cm (post debridement). Under fix and shift technique, stable fixation involved primary external fixator application or primary intramedullary nailing of the tibial fracture and immediate soft tissue cover involved septocutaneous shift, i.e., shifting of fasciocutaneous segments based on septocutaneous perforators. Primary fracture union rate was 50% and reoperation rate (bone stimulating procedures) was 50%. Overall fracture union rate was 100%. The rate of malunion was 14% and deep infection was 16%. Failure of septocutaneous shift was 2.7%. There was no incidence of amputation. Management of Gustilo Anderson III B open tibial fractures with "fix and shift" technique has resulted in better outcome in terms of skeletal factors (primary fracture union, overall union, and time for union and malunion) and soft tissue factors (wound healing, flap failure, access to secondary procedures, and esthetic appearance) when compared to standard methods adopted earlier. Hence, "fix and shift" could be recommended as one of the treatment modalities for open III B tibial fractures.

  16. [effectiveness of open reduction and internal fixation without opening joint capsule on tibial plateau fracture].

    PubMed

    Chen, Qi; Xu, Xiaofeng; Huang, Yonghui; Cao, Xingbing; Meng, Chen; Cao, Xueshu; Wei, Changbao

    2014-12-01

    To introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. Between July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incision length, incision healing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. The intraoperative blood loss in trial group was significantly less than that in control group (P < 0.05). The incision length in trial group was significantly shorter than that in control group (P < 0.05). Difference was not significant in operation time and the rate of incision healing between 2 groups (P > 0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture healing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P > 0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). It can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for

  17. External versus internal fixation for bicondylar tibial plateau fractures: systematic review and meta-analysis.

    PubMed

    Metcalfe, David; Hickson, Craig J; McKee, Lesley; Griffin, Xavier L

    2015-12-01

    It is uncertain whether external fixation or open reduction internal fixation (ORIF) is optimal for patients with bicondylar tibial plateau fractures. A systematic review using Ovid MEDLINE, Embase Classic, Embase, AMED, the Cochrane Library, Open Grey, Orthopaedic Proceedings, WHO International Clinical Trials Registry Platform, Current Controlled Trials, US National Institute for Health Trials Registry, and the Cochrane Central Register of Controlled Trials. The search was conducted on 3rd October 2014 and no language limits were applied. Inclusion criteria were all clinical study designs comparing external fixation with open reduction internal fixation of bicondylar tibial plateau fractures. Studies of only one treatment modality were excluded, as were those that included unicondylar tibial plateau fractures. Treatment effects from studies reporting dichotomous outcomes were summarised using odds ratios. Continuous outcomes were converted to standardized mean differences to assess the treatment effect, and inverse variance methods used to combine data. A fixed effect model was used for meta-analyses. Patients undergoing external fixation were more likely to have returned to preinjury activities by six and twelve months (P = 0.030) but not at 24 months follow-up. However, external fixation was complicated by a greater number of infections (OR 2.59, 95 % CI 1.25-5.36, P = 0.01). There were no statistically significant differences in the rates of deep infection, venous thromboembolism, compartment syndrome, or need for re-operation between the two groups. Although external fixation and ORIF are associated with different complication profiles, both are acceptable strategies for managing bicondylar tibial plateau fractures.

  18. Transverse Stress Fracture of the Proximal Patella

    PubMed Central

    Atsumi, Satoru; Arai, Yuji; Kato, Ko; Nishimura, Akinobu; Nakazora, Shigeto; Nakagawa, Shuji; Ikoma, Kazuya; Fujiwara, Hiroyoshi; Sudo, Akihiro; Kubo, Toshikazu

    2016-01-01

    Abstract Among stress fractures associated with sports activities, patellar stress fracture is rare. Regarding patella stress fractures, so far only distal transverse or lateral longitudinal fractures have been reported, but there are no reports of transverse fractures occurring in the proximal patella. We describe an extremely rare case of transverse stress fracture of proximal patella in a 9-year-old athlete. A 9-year old boy, who participated in sports (sprints and Kendo) presented with left knee pain without any external injury. In plain radiographs, a fracture line was observed in the proximal 1/3 of the left patella, and a patella stress fracture was diagnosed. For treatment, because 7 months of conservative therapy showed no improvement, internal fixation was carried out using Acutrak screws, and bone union was thus achieved. Three months after the operation, he was able to return to his previous level of athletic sports activity. Regarding the mechanism of onset, it is believed that the causes are longitudinal traction force and patellofemoral contact pressure. On the other hand, the contact region of the patella with the femur changes with the flexion angle of the knee. In the current case, the fracture occurred at a site where the patella was in contact with the femur at a flexion angle of >90°, so it is believed that it occurred as a clinical condition from being subjected to repeated longitudinal traction force and patellofemoral contact pressure at a flexion angle of >90°, during the sports activities of sprints and Kendo. The nonunion of the transverse stress fracture of his proximal patella was successfully treated with internal fixation using Acutrak screws. PMID:26871789

  19. Complex tibial fractures are associated with lower social classes and predict early exit from employment and worse patient-reported QOL: a prospective observational study of 46 complex tibial fractures treated with a ring fixator.

    PubMed

    Elsoe, Rasmus; Larsen, Peter; Petruskevicius, Juozas; Kold, Søren

    2018-04-01

    The long-term outcomes following complex fractures of the tibia are reported to carry a risk of knee pain, malalignment, articular injury and post-traumatic osteoarthritis. The main objective of this study was to account for the patient-reported quality of life (QOL) 12 months after ring fixator removal in patients with a complex tibial fracture. Secondary objectives included a review of the socio-economic characteristics of the patient group and the rate of return to work in the study period. A prospective follow-up study was conducted of 60 patients with complex fractures of the tibia treated with ring external fixation. Patient-reported outcomes, radiological outcomes and socio-economic status including employment status of the patients were obtained 12 months after frame removal. Forty-six patients completed the assessment 12 months after frame removal (77%). The mean age of the patient at the time of fracture was 54.6 years (range 31-86). There were 19 males and 27 females. At 12 months after frame removal, the mean EQ5D-5L index was 0.66 (CI 0.60-0.72). The mean EQ5D-5L VAS was 69 (CI 61-76). When this was compared to the established reference population from Denmark, the study population showed a significantly worse EQ5D-5L index. The majority of patients (87%) were in the lower social classes suggesting a higher degree of social deprivation in the study population. Twenty-seven per cent of patients who were employed prior to injury had returned to employment at approximately 19 months following fracture. The onset of post-traumatic osteoarthritis was present in the knee joint in 29% of patients following a proximal intra-articular fracture, whereas osteoarthritis was present at the ankle joint in 35% of patients following a distal intra-articular fracture 12 months after frame removal. This study indicates that at 12 months after frame removal there are poorer patient-reported QOL as when compared to reference populations. Furthermore, this study

  20. Defining the Lower Limit of a "Critical Bone Defect" in Open Diaphyseal Tibial Fractures.

    PubMed

    Haines, Nikkole M; Lack, William D; Seymour, Rachel B; Bosse, Michael J

    2016-05-01

    To determine healing outcomes of open diaphyseal tibial shaft fractures treated with reamed intramedullary nailing (IMN) with a bone gap of 10-50 mm on ≥50% of the cortical circumference and to better define a "critical bone defect" based on healing outcome. Retrospective cohort study. Forty patients, age 18-65, with open diaphyseal tibial fractures with a bone gap of 10-50 mm on ≥50% of the circumference as measured on standard anteroposterior and lateral postoperative radiographs treated with IMN. IMN of an open diaphyseal tibial fracture with a bone gap. Level-1 trauma center. Healing outcomes, union or nonunion. Forty patients were analyzed. Twenty-one (52.5%) went on to nonunion and nineteen (47.5%) achieved union. Radiographic apparent bone gap (RABG) and infection were the only 2 covariates predicting nonunion outcome (P = 0.046 for infection). The RABG was determined by measuring the bone gap on each cortex and averaging over 4 cortices. Fractures achieving union had a RABG of 12 ± 1 mm versus 20 ± 2 mm in those going on to nonunion (P < 0.01). This remained significant when patients with infection were removed. Receiver operator characteristic analysis demonstrated that RABG was predictive of outcome (area under the curve of 0.79). A RABG of 25 mm was the statistically optimal threshold for prediction of healing outcome. Patients with open diaphyseal tibial fractures treated with IMN and a <25 mm RABG have a reasonable probability of achieving union without additional intervention, whereas those with larger gaps have a higher probability of nonunion. Research investigating interventions for RABGs should use a predictive threshold for defining a critical bone defect that is associated with greater than 50% risk of nonunion without supplementary treatment. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  1. Delayed presentation is no barrier to satisfactory outcome in the management of open tibial fractures.

    PubMed

    Ashford, Robert U; Mehta, Janak A; Cripps, Robin

    2004-04-01

    The management of open tibial fractures is a challenge to all orthopaedic trauma surgeons. The major goals are fracture union, uncomplicated soft tissue healing and return to pre-injury level of function. The geographical isolation and vastness of the Northern Territory of Australia complicates the management of these injuries by adding a significant delay to treatment. Forty-five patients sustained 48 open tibial fractures over the 30-month period of the study. Twelve received primary surgical treatment within 6h of injury but 33 were treated more than 6h after injury. The mean time to treatment in this latter group was 12h 15min (median 9h 45min, range 6-37h). The majority of injuries were high energy, with 23 patients having multiple injuries and 29 fractures (60%) being classified as AO C3 with 35 (73%) having Gustilo III soft tissue injuries. There was a mean time to union of 7.5 months and an overall complication rate of 42.2%. Thirteen patients (29%) required additional (late) surgical procedures subsequent to definitive fracture and soft tissue management. The zone of injury infection rate was 12.5%. The high incidence of open tibial fractures places a large financial burden on the state. However, despite the absence of a plastic surgical service and delays in presentation, satisfactory outcomes can be obtained by the application of the established surgical principles of thorough debridement, soft tissue management and fracture stabilisation.

  2. Risk factors associated with the occurrence of proximal humerus fractures in patients with rheumatoid arthritis: a custom strategy for preventing proximal humerus fractures.

    PubMed

    Ochi, Kensuke; Furuya, Takefumi; Ishibashi, Mina; Watanabe, Makiko; Ikari, Katsunori; Taniguchi, Atsuo; Yamanaka, Hisashi; Momohara, Shigeki

    2016-02-01

    To our knowledge, no prior report focused on the risk factors for proximal humerus fractures in patients with rheumatoid arthritis. The purpose of this study was to evaluate the association between potential risk factors and the occurrence of proximal humerus fractures in patients with rheumatoid arthritis. A total of 11,907 patients with rheumatoid arthritis were enrolled in our observational cohort rheumatoid arthritis study between 2000 and 2012. Self-reported proximal humerus fractures were verified using the patients' medical records. Cox proportional hazard models were used to analyze the independent contribution of risk factors to the occurrence of proximal humerus fractures. During follow-up (mean 5.6 years), 92 proximal humerus fractures were verified in 91 patients. Multivariate Cox regression analyses estimated that the hazard ratios of sustaining a proximal humerus fracture were 1.37 for every 10-year increase in age [95 % confidence interval (CI) 1.10-1.70; P < 0.01], 1.95 for increases in serum C-reactive protein levels (mg/100 mL; 95 % CI 1.15-3.34; P < 0.05), 2.13 for a history of fractures (95 % CI 1.34-3.40; P < 0.01), 1.07 for the daily prednisolone dose (per mg; 95 % CI 1.01-1.13; P < 0.05), and 1.97 for oral bisphosphonate use (95 % CI 1.20-3.23; P < 0.01). Better control of rheumatoid arthritis with a smaller daily prednisolone dose in elderly patients with a history of fractures may be important for preventing proximal humerus fractures.

  3. Ideal tibial intramedullary nail insertion point varies with tibial rotation.

    PubMed

    Walker, Richard M; Zdero, Rad; McKee, Michael D; Waddell, James P; Schemitsch, Emil H

    2011-12-01

    The aim of the study was to investigate how superior entry point varies with tibial rotation and to identify landmarks that can be used to identify suitable radiographs for successful intramedullary nail insertion. The proximal tibia and knee were imaged for 12 cadaveric limbs undergoing 5° increments of internal and external rotation. Medial and lateral arthrotomies were performed, the ideal superior entry point was identified, and a 2-mm Kirschner wire inserted. A second Kirschner wire was sequentially placed at the 5-mm and then the 10-mm position, both medial and lateral to the initial Kirschner wire. Radiographs of the knee were obtained for all increments. The changing position of the ideal nail insertion point was recorded. A 30° arc (range, 25°-40°) provided a suitable anteroposterior radiograph. On the neutral anteroposterior radiograph, the Kirschner wire was 54% ± 1.5% (range, 51-56%) from the medial edge of the tibial plateau. For every 5° of rotation, the Kirschner wire moved 3% of the plateau width. During external rotation, a misleading medial entry point was obtained. A fibular bisector line correlated with an entry point that was ideal or up to 5 mm lateral to this but never medial. The film that best showed the fibular bisector line was between 0° and 10° of internal rotation of the tibia. The fibula head bisector line can be used to avoid choosing external rotation views and, thus, avoid medial insertion points. The current results may help the surgeon prevent malalignment during intramedullary nailing in proximal tibial fractures.

  4. Indirect reduction technique using a distraction support in minimally invasive percutaneous plate osteosynthesis of tibial shaft fractures.

    PubMed

    Dong, Wen-Wei; Shi, Zeng-Yuan; Liu, Zheng-Xin; Mao, Hai-Jiao

    2016-12-01

    To describe an indirect reduction technique during minimally invasive percutaneous plate osteosynthesis (MIPPO) of tibial shaft fractures with the use of a distraction support. Between March 2011 and October 2014, 52 patients with a mean age of 48 years (16-72 years) sustaining tibial shaft fractures were included. All the patients underwent MIPPO for the fractures using a distraction support prior to insertion of the plate. Fracture angular deformity was assessed by goni- ometer measurement on preoperative and postoperative images. Preoperative radiographs revealed a mean of 7.6°(1.2°-28°) angulation in coronal plane and a mean of 6.8°(0.5°-19°) angulation in sagittal plane. Postoperative anteroposterior and lateral radio- graphs showed a mean of 0.8°(0°-4.0°) and 0.6°(0°-3.6°) of varus/valgus and apex anterior/posterior angulation, respectively. No intraoperative or postoperative complications were noted. This study suggests that the distraction support during MIPPO of tibial shaft fractures is an effective and safe method with no associated complications.

  5. Evaluation of stability of osteosynthesis with K-wires on an artificial model of tibial malleolus fracture.

    PubMed

    Bumči, Igor; Vlahović, Tomislav; Jurić, Filip; Žganjer, Mirko; Miličić, Gordana; Wolf, Hinko; Antabak, Anko

    2015-11-01

    Paediatric ankle fractures comprise approximately 4% of all paediatric fractures and 30% of all epiphyseal fractures. Integrity of the ankle "mortise", which consists of tibial and fibular malleoli, is significant for stability and function of the ankle joint. Tibial malleolar fractures are classified as SH III or SH IV intra-articular fractures and, in cases where the fragments are displaced, anatomic reposition and fixation is mandatory. Type SH III-IV fractures of the tibial malleolus are usually treated with open reduction and fixation with cannulated screws that are parallel to the physis. Two K-wires are used for temporary stabilisation of fragments during reduction. A third "guide wire" for the screw is then placed parallel with the physis. Considering the rules of mechanics, it is assumed that the two temporary pins with the additional third pin placed parallel to the physis create a strong triangle and thus provide strong fracture fixation. To prove this hypothesis, an experiment was conducted on the artificial models of the lower end of the tibia from the company "Sawbones". Each model had been sawn in a way that imitates the fracture of medial malleoli and then reattached with 1.8mm pins in various combinations. Prepared models were then tested for tensile and pressure forces. The least stable model was that in which the fractured pieces were attached with only two parallel pins. The most stable model comprised three pins, where two crossed pins were inserted in the opposite compact bone and the third pin was inserted through the epiphysis parallel with and below the growth plate. A potential method of choice for fixation of tibial malleolar fractures comprises three K-wires, where two crossed pins are placed in the opposite compact bone and one is parallel with the growth plate. The benefits associated with this method include shorter operating times and avoidance of a second operation for screw removal. Copyright © 2015 Elsevier Ltd. All rights

  6. Analysis of anatomic periarticular tibial plate fit on normal adults.

    PubMed

    Goyal, Kanu S; Skalak, Anthony S; Marcus, Randall E; Vallier, Heather A; Cooperman, Daniel R

    2007-08-01

    Implant manufacturers are producing anatomically contoured periarticular plates to improve the treatment of proximal tibia fractures. We assessed the accuracy of the designation anatomic. We applied eight-hole medial and lateral anatomically contoured periarticular plates to 101 cadaveric tibiae. The tibiae and the plate fits were mapped, quantified, and analyzed using a MicroScribe G2LX digitizer, Rhinoceros software, and MATLAB software. By corresponding the clinical appearance of good fit with our digital findings, we created numerical criteria for plate fit in three planes: coronal (volume of free space between the plate and bone), sagittal (alignment with the tibial plateau and shaft), and axial (match in curvature between the proximal horizontal part of the plate and the tibial plateau). An anatomic fit should mirror the shape of the tibia in all three planes, and only four medial and four lateral plate fits qualified. Recognizing and understanding the substantial variations in fit that exist between anatomically contoured plates and the tibia may help lead to a more stable fixation and prevent malreduction of the fracture and/or soft tissue impingement.

  7. [Comparison of LCP and locked intramedullary nailing fixation in treatment of tibial diaphysis fractures].

    PubMed

    Huang, Peng; Tang, Peifu; Yao, Qi

    2007-11-01

    To evaluate the treatment results of LCP and locked intramedullary nailing for tibial diaphysis fractures. From October 2003 to April 2006, 55 patients with tibial diaphysis fractures (58 fractures) were treated. Of them there were 39 males and 16 females with an average of 39 years years ( 14 to 62 years). The fractures were on the left side in 27 patients and on the right side in 31 patients (3 patients had bilateral involvement). Thirty-four fractures were treated by intramedullary nailing (intramedullary nailing group) and 24 fractures by LCP fixation (LCP group). The average disease course was 3 days (intramedullary nailing group) and 3.1 days (LCP group). The operation time, the range of motion of knee and ankle joints, fracture healing time, and complications were evaluated. The patients were followed up 8-26 months (13 months on average). The operation time was 84.0+/-9.2 min (intramedullary nailing group) and 69.0+/-8.4 min (LCP group); the average cost in hospital was yen 19,297.78 in the intramedullary nailing group and yen 14,116.55 in the LCP group respectively, showing significant differences (P < 0.05). The flexion and extension of knee joint was 139.0 +/- 3.7 degrees and 4.0 +/- 0.7 degrees in intramedullary nailing group and 149.0+/-4.2 degrees and 0+/-0.4 degrees in LCP group, showing no significant difference (P>0.05). The doral flexion and plantar flexion of ankle joint were 13.0+/-1.7 degrees and 41.0+/-2.6 degrees in intramedullary nailing group, and 10.0+/-1.4 degrees and 44.0+/-2.3 degrees in LCP group, showing no significant differences (P>0.05). The mean healing time was 3.3 months in intramedullary nailing group, and 3. 1 months in LCP group. Length discrepancy occurred in 1 case (2.5 cm), delayed union in 1 case and nailing end trouble in 3 cases in intramedullary nailing group; moreover rotation deformity occurred 1 case and anterior knee pain occurred in 6 cases (17.1%). One angulation and open fracture developed osteomyelitis in 1

  8. Anatomy and classification of the posterior tibial fragment in ankle fractures.

    PubMed

    Bartoníček, Jan; Rammelt, Stefan; Kostlivý, Karel; Vaněček, Václav; Klika, Daniel; Trešl, Ivo

    2015-04-01

    The aim of this study was to analyze the pathoanatomy of the posterior fragment on the basis of a comprehensive CT examination, including 3D reconstructions, in a large patient cohort. One hundred and forty one consecutive individuals with an ankle fracture or fracture-dislocation of types Weber B or Weber C and evidence of a posterior tibial fragment in standard radiographs were included in the study. The mean patient age was 49 years (range 19-83 years). The exclusion criteria were patients below 18 years of age, inability to provide written consent, fractures of the tibial pilon, posttraumatic arthritis and pre-existing deformities. In all patients, post-injury radiographs were obtained in anteroposterior, mortise and lateral views. All patients underwent CT scanning in transverse, sagittal and frontal planes. 3D CT reconstruction was performed in 91 patients. We were able to classify 137 cases into one of the following four types with constant pathoanatomic features: type 1: extraincisural fragment with an intact fibular notch, type 2: posterolateral fragment extending into the fibular notch, type 3: posteromedial two-part fragment involving the medial malleolus, type 4: large posterolateral triangular fragment. In the 4 cases it was not possible to classify the type of the posterior tibial fragment. These were collectively termed type 5 (irregular, osteoporotic fragments). It is impossible to assess the shape and size of the posterior malleolar fragment, involvement of the fibular notch, or the medial malleolus, on the basis of plain radiographs. The system that we propose for classification of fractures of the posterior malleolus is based on CT examination and takes into account the size, shape and location of the fragment, stability of the tibio-talar joint and the integrity of the fibular notch. It may be a useful indication for surgery and defining the most useful approach to these injuries.

  9. Site Specific Effects of Zoledronic Acid during Tibial and Mandibular Fracture Repair

    PubMed Central

    Yu, Yan Yiu; Lieu, Shirley; Hu, Diane; Miclau, Theodore; Colnot, Céline

    2012-01-01

    Numerous factors can affect skeletal regeneration, including the extent of bone injury, mechanical loading, inflammation and exogenous molecules. Bisphosphonates are anticatabolic agents that have been widely used to treat a variety of metabolic bone diseases. Zoledronate (ZA), a nitrogen-containing bisphosphonate (N-BP), is the most potent bisphosphonate among the clinically approved bisphosphonates. Cases of bisphosphonate-induced osteonecrosis of the jaw have been reported in patients receiving long term N-BP treatment. Yet, osteonecrosis does not occur in long bones. The aim of this study was to compare the effects of zoledronate on long bone and cranial bone regeneration using a previously established model of non-stabilized tibial fractures and a new model of mandibular fracture repair. Contrary to tibial fractures, which heal mainly through endochondral ossification, mandibular fractures healed via endochondral and intramembranous ossification with a lesser degree of endochondral ossification compared to tibial fractures. In the tibia, ZA reduced callus and cartilage formation during the early stages of repair. In parallel, we found a delay in cartilage hypertrophy and a decrease in angiogenesis during the soft callus phase of repair. During later stages of repair, ZA delayed callus, cartilage and bone remodeling. In the mandible, ZA delayed callus, cartilage and bone remodeling in correlation with a decrease in osteoclast number during the soft and hard callus phases of repair. These results reveal a more profound impact of ZA on cartilage and bone remodeling in the mandible compared to the tibia. This may predispose mandible bone to adverse effects of ZA in disease conditions. These results also imply that therapeutic effects of ZA may need to be optimized using time and dose-specific treatments in cranial versus long bones. PMID:22359627

  10. Dipyrone has no effects on bone healing of tibial fractures in rats

    PubMed Central

    Gali, Julio Cesar; Sansanovicz, Dennis; Ventin, Fernando Carvalho; Paes, Rodrigo Henrique; Quevedo, Francisco Carlos; Caetano, Edie Benedito

    2014-01-01

    OBJECTIVE: To evaluate the effect of dipyrone on healing of tibial fractures in rats. METHODS: Fourty-two Wistar rats were used, with mean body weight of 280g. After being anesthetized, they were submitted to closed fracture of the tibia and fibula of the right posterior paw through manual force. The rats were randomly divided into three groups: the control group that received a daily intraperitoneal injection of saline solution; group D-40, that received saline injection containing 40mg/Kg dipyrone; and group D-80, that received saline injection containing 80mg/Kg dipyrone. After 28 days the rats were sacrificed and received a new label code that was known by only one researcher. The fractured limbs were then amputated and X-rayed. The tibias were disarticulated and subjected to mechanical, radiological and histological evaluation. For statistical analysis the Kruskal-Wallis test was used at a significance level of 5%. RESULTS: There wasn't any type of dipyrone effect on healing of rats tibial fractures in relation to the control group. CONCLUSION: Dipyrone may be used safely for pain control in the treatment of fractures, without any interference on bone healing. Level of Evidence II, Controlled Laboratory Study. PMID:25246852

  11. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    PubMed

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  12. [Treatment of Schatzker IV tibial plateau fractures with arthroscopy combined with MIPPO technique].

    PubMed

    Li, Jian-Wen; Ye, Feng; Bi, Da-Wei; Zheng, Xiao-Dong; Chen, Jian-Liang

    2018-02-25

    To discusses the clinical effects of arthroscopy combined with minimally invasive percutaneous plate osteosynthesis(MIPPO) technology in treating Schatzker IV tibial plateau fractures. From January 2012 to January 2016, 19 patients with Schatzker type IV tibial plateau fractures were treated with arthroscopy combined with minimally invasive technique including 12 males and 7 females with an average age of 46.5 years old ranging from 19 to 78 years old. Patients were suffering knee pain, swelling, flexion and extension limited, and other symptoms preoperative. Patients were followed up and assessed by Rasmussen knee function score. No infection, traumatic arthritis, and knee joint valgus occurred after operation. Nineteen cases were followed up for 12 to 24 months with an average of 18.6 months. Fracture healing time was 3 to 5 months with an average of 3.8 months. The knee pain and limited mobility improved significantly. The range of autonomic movement of joints was from 90 to 136 degrees. According to Rasmussen functional score criteria, the total score was 27.00±2.49, the result was excellent in 16 cases, good in 2 cases, fair in 1 case. Arthroscopic treatment for Schatzker type IV tibial plateau fractures combined with MIPPO can simultaneously treat internal structural injuries such as meniscus and other knee joints, with less trauma, fewer complications, and faster joint function recovery, but we must strictly grasp surgical indications and avoid expanding injuries. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  13. [Influencing factors for trauma-induced tibial infection in underground coal mine].

    PubMed

    Meng, W Z; Guo, Y J; Liu, Z K; Li, Y F; Wang, G Z

    2016-07-20

    Objective: To investigate the influencing factors for trauma-induced tibial infection in underground coal mine. Methods: A retrospective analysis was performed for the clinical data of 1 090 patients with tibial fracture complicated by bone infection who were injured in underground coal mine and admitted to our hospital from January 1995 to August 2015, including the type of trauma, injured parts, severity, and treatment outcome. The association between risk factors and infection was analyzed. Results: Among the 1 090 patients, 357 had the clinical manifestations of acute and chronic bone infection, 219 had red and swollen legs with heat pain, and 138 experienced skin necrosis, rupture, and discharge of pus. The incidence rates of tibial infection from 1995 to 2001, from 2002 to 2008, and from 2009 to 2015 were 31%, 26.9%, and 20.2%, respectively. The incidence rate of bone infection in the proximal segment of the tibia was significantly higher than that in the middle and distal segments (42.1% vs 18.9%/27.1%, P <0.01) . As for patients with different types of trauma (Gustilo typing) , the patients with type III fracture had a significantly higher incidence rate of bone infection than those with type I/II infection (52.8% vs 21.8%/24.6%, P <0.01) . The incidence rates of bone infection after bone traction, internal fixation with steel plates, fixation with external fixator, and fixation with intramedullary nail were 20.7%, 43.5%, 21.4%, and 26.1%, respectively, suggesting that internal fixation with steel plates had a significantly higher incidence rate of bone infection than other fixation methods ( P <0.01) . The multivariate logistic regression analysis showed that the position of tibial fracture and type of fracture were independent risk factors for bone infection. Conclusion: There is a high incidence rate of trauma-induced tibial infection in workers in underground coal mine. The position of tibial fracture and type of fracture are independent risk factors

  14. Reliability of a four-column classification for tibial plateau fractures.

    PubMed

    Martínez-Rondanelli, Alfredo; Escobar-González, Sara Sofía; Henao-Alzate, Alejandro; Martínez-Cano, Juan Pablo

    2017-09-01

    A four-column classification system offers a different way of evaluating tibial plateau fractures. The aim of this study is to compare the intra-observer and inter-observer reliability between four-column and classic classifications. This is a reliability study, which included patients presenting with tibial plateau fractures between January 2013 and September 2015 in a level-1 trauma centre. Four orthopaedic surgeons blindly classified each fracture according to four different classifications: AO, Schatzker, Duparc and four-column. Kappa, intra-observer and inter-observer concordance were calculated for the reliability analysis. Forty-nine patients were included. The mean age was 39 ± 14.2 years, with no gender predominance (men: 51%; women: 49%), and 67% of the fractures included at least one of the posterior columns. The intra-observer and inter-observer concordance were calculated for each classification: four-column (84%/79%), Schatzker (60%/71%), AO (50%/59%) and Duparc (48%/58%), with a statistically significant difference among them (p = 0.001/p = 0.003). Kappa coefficient for intr-aobserver and inter-observer evaluations: Schatzker 0.48/0.39, four-column 0.61/0.34, Duparc 0.37/0.23, and AO 0.34/0.11. The proposed four-column classification showed the highest intra and inter-observer agreement. When taking into account the agreement that occurs by chance, Schatzker classification showed the highest inter-observer kappa, but again the four-column had the highest intra-observer kappa value. The proposed classification is a more inclusive classification for the posteromedial and posterolateral fractures. We suggest, therefore, that it be used in addition to one of the classic classifications in order to better understand the fracture pattern, as it allows more attention to be paid to the posterior columns, it improves the surgical planning and allows the surgical approach to be chosen more accurately.

  15. Prevention of arthrofibrosis after arthroscopic screw fixation of tibial spine fracture in children and adolescents.

    PubMed

    Parikh, Shital N; Myer, David; Eismann, Emily A

    2014-01-01

    Arthrofibrosis is a major complication of tibial spine fracture treatment in children, potentially resulting in knee pain, quadriceps weakness, altered gait, decreased function, inability to return to sports, and long-term osteoarthritis. Thus, prevention rather than treatment of arthrofibrosis is desirable. The purpose of this study was to evaluate an aggressive postoperative rehabilitation and early intervention approach to prevent permanent arthrofibrosis after tibial spine fracture treatment and to compare epiphyseal and transphyseal screws for fixation. A consecutive series of 24 patients younger than age 18 with displaced type II and III tibial spine fractures who underwent arthroscopic reduction and screw fixation between 2006 and 2011 were retrospectively reviewed. Final range of motion was compared between patients with epiphyseal (n=12) and transphyseal (n=9) screws. One-third (4 of 12) of patients with epiphyseal screws underwent arthroscopic debridement and screw removal approximately 3 months postoperatively; 3 patients lacked 5° to 15° of extension, 1 experienced pain with extension, and 1 had radiographic evidence of screw pullout, loss of reduction, and resultant malunion. In the transphyseal screw group, 3 patients had 10° loss of extension, and all corrected after arthroscopic debridement and screw removal. The two groups did not significantly differ in time to hardware removal or return to sports or final range of motion. No growth disturbances were identified in patients after transphyseal screw removal. An aggressive approach of postoperative rehabilitation and early intervention after arthroscopic reduction and screw fixation of tibial spine fractures in children was successful in preventing permanent arthrofibrosis.

  16. Distal tibial fractures and non-unions treated with shortened intramedullary nail.

    PubMed

    Megas, P; Zouboulis, P; Papadopoulos, A X; Karageorgos, A; Lambiris, E

    2003-01-01

    We reviewed 18 patients, 14 with acute fractures and four with non-union of the distal tibia, treated between 1990 and 2001 with a shortened, reamed intramedullary nail. The mean follow-up was 38 (8-144) months. The fractures united at an average of 16 (12-18) weeks and the non-unions at 20 (12-30) weeks. Two patients required nail dynamization. No limb shortening nor material failures were seen. All patients returned to normal daily activities. Although technically demanding, intramedullary nailing for distal tibial fractures and non-unions with a shortened nail represents a safe and reliable method.

  17. The Effect of Sagittal Plane Deformities after Tibial Plateau Fractures to Functions and Instability of Knee Joint.

    PubMed

    Erdil, M; Yildiz, F; Kuyucu, E; Sayar, Ş; Polat, G; Ceylan, H H; Koçyiğit, F

    2016-01-01

    The objective of this study is to evaluate the effect of posterior tibial slope after fracture healing on antero-posterior knee laxity, functional outcome and patient satisfaction. 126 patients who were treated for tibial plateau fractures between 2008-2013 in the orthopedics and traumatology department of our institution were evaluated for the study. Patients were treated with open reduction and internal fixation, arthroscopy assisted minimally invasive osteosynthesis or conservative treatment. Mean posterior tibial slope after the treatment was 6.91 ± 5.11 and there was no significant difference when compared to the uninvolved side 6.42 ± 4,21 (p = 0.794). Knee laxity in anterior-posterior plane was 6.14 ± 2.11 and 5.95 ± 2.25 respectively on healthy and injured side. The difference of mean laxity in anterior-posterior plane between two sides was statistically significant. In this study we found no difference in laxity between the injured and healthy knees. However Tegner score decreased significantly in patients who had greater laxity difference between the knees. We did not find significant difference between fracture type and laxity, IKDC functional scores independent of the ligamentous injury. In conclusion despite coronal alignment is taken into consideration in treatment of tibial plateau fractures, sagittal alignment is reasonably important for stability and should not be ignored.

  18. Total Knee Arthroplasty for Osteoarthritis Secondary to Fracture of the Tibial Plateau. A Prospective Matched Cohort Study.

    PubMed

    Lizaur-Utrilla, Alejandro; Collados-Maestre, Isabel; Miralles-Muñoz, Francisco A; Lopez-Prats, Fernando A

    2015-08-01

    A prospective matched cohort study was performed to compare outcomes of total knee arthroplasties (TKA) between 29 patients with posttraumatic osteoarthritis (POA) after a fracture of tibial plateau and 58 patients underwent routine TKA. Mean follow-up was 6.7 years. There were no significant differences in KSS, WOMAC, SF12 scores or range of motion. In the control group there were no complications. In the posttraumatic group, complications occurred in 4 patients (13.7%) (P=0.010) including partial patellar tendon detachment, superficial infection, skin necrosis, and knee stiffness. Only this last patient required revision for manipulation under anesthesia. Also, there was a revision for tibial aseptic loosening in each group. TKA is an effective treatment for POA after tibial plateau fracture. We recommend the prior removal of hardware, as well as tibial tubercle osteotomy when necessary. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Utility of cement injection to stabilize split-depression tibial plateau fracture by minimally invasive methods: A finite element analysis.

    PubMed

    Belaid, D; Vendeuvre, T; Bouchoucha, A; Brémand, F; Brèque, C; Rigoard, P; Germaneau, A

    2018-05-08

    Treatment for fractures of the tibial plateau is in most cases carried out by stable fixation in order to allow early mobilization. Minimally invasive technologies such as tibioplasty or stabilization by locking plate, bone augmentation and cement filling (CF) have recently been used to treat this type of fracture. The aim of this paper was to determine the mechanical behavior of the tibial plateau by numerically modeling and by quantifying the mechanical effects on the tibia mechanical properties from injury healing. A personalized Finite Element (FE) model of the tibial plateau from a clinical case has been developed to analyze stress distribution in the tibial plateau stabilized by balloon osteoplasty and to determine the influence of the cement injected. Stress analysis was performed for different stages after surgery. Just after surgery, the maximum von Mises stresses obtained for the fractured tibia treated with and without CF were 134.9 MPa and 289.9 MPa respectively on the plate. Stress distribution showed an increase of values in the trabecular bone in the treated model with locking plate and CF and stress reduction in the cortical bone in the model treated with locking plate only. The computed results of stresses or displacements of the fractured models show that the cement filling of the tibial depression fracture may increase implant stability, and decrease the loss of depression reduction, while the presence of the cement in the healed model renders the load distribution uniform. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Treatment of proximal ulna and olecranon fractures by dorsal plating.

    PubMed

    Kloen, Peter; Buijze, Geert A

    2009-12-01

    Anatomic reconstruction of proximal ulna and olecranon fractures allowing early mobilization and prevention of ulnohumeral arthritis. Comminuted olecranon or proximal ulna fractures (including Monteggia fractures), olecranon fractures extending distally from the coronoid process, nonunions of the proximal ulna, segmental fractures of the proximal ulna extending into the shaft, fractures of the proximal ulna associated with a coronoid fracture. Patients in poor general condition. Soft-tissue defects around the elbow preventing wound closure over the plate. Pediatric fractures with open growth plates where screws would cross the physis. Posterior approach to the elbow. Hinging the fracture site open by extension of the proximal fragment based on triceps insertion. Fracture involvement of the coronoid with a large displaced fracture fragment can generally be reduced through the fracture side. Reconstruction with temporary Kirschner wires. Fixation by placing a (precontoured) plate around the tip of the olecranon with a long intramedullary screw and orthogonal (uni)cortical screws in the shaft. Radial head pathology can be addressed - if needed - through the same incision. Internal fixation, resection or prosthetic replacement of the radial head is done based on injury pattern/stability. Functional rehabilitation using active assisted range of motion of the elbow may be started immediately out of splint. Posterior splint for 7-10 days to allow wound healing. Between 2003 and July 2008, 26 patients were treated with posterior plating of the proximal ulna and olecranon using this strategy. There were 23 acute fractures (of which one was referred for revision after suboptimal fixation a few days earlier), one nonunion that became traumatized, and two nascent malunions. A midline posterior approach allowed addressing both ulna and radial head pathology. The plate was contoured to wrap around the olecranon. All fractures healed. There were one postoperative infection, one

  1. Early prophylactic autogenous bone grafting in type III open tibial fractures.

    PubMed

    Kesemenli, Cumhur C; Kapukaya, Ahmet; Subaşi, Mehmet; Arslan, Huseyin; Necmioğlu, Serdar; Kayikçi, Cuma

    2004-08-01

    The authors report the results achieved in patients with type III open tibial fractures who underwent primary autogenous bone grafting at the time of debridement and skeletal stabilisation. Twenty patients with a mean age of 35.8 years (range, 24-55) were treated between 1996 and 1999. Eight fractures were type IIIA, 11 were type IIIB, and 1 was type IIIC. At the index procedure, wound debridement, external fixation and autogenous bone grafting with bone coverage were achieved. The mean follow-up period was 46 months (range, 34-55). The mean time to fixator removal was 21 weeks (range, 14-35), and the mean time to union was 28 weeks (range, 19-45). Skin coverage was achieved by a myocutaneous flap in 2 patients, late primary closure in 4, and split skin grafting in 14. One (5%) of the patients experienced delayed union, and 1 (5%) developed infection. In tibial type III open fractures, skin coverage may be delayed, using the surrounding soft tissue to cover any exposed bone after thorough débridement and wound cleansing. Primary prophylactic bone grafting performed at the same time reduces the rate of delayed union, shortens the time to union, and does not increase the infection rate.

  2. Hybrid External Fixation for Arbeitsgemeinschaft für Osteosynthesefragen (AO) 43-C Tibial Plafond Fractures.

    PubMed

    Abd-Almageed, Emad; Marwan, Yousef; Esmaeel, Ali; Mallur, Amarnath; El-Alfy, Barakat

    2015-01-01

    Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 43-C tibial plafond/pilon fractures represent a challenge for the treating orthopedic surgeon. We assessed the outcomes of using hybrid external fixation for this fracture type. The present prospective cohort study was started in August 2009 and ended by July 2012. Thirty consecutive patients (mean age 37.4 ± 10.7 years) with a type C tibial plafond fracture who had presented to our tertiary care orthopedic hospital were included. Motor vehicle accidents and fall from height were the cause of the fracture in 14 (46.7%) and 13 (43.3%) patients, respectively. A type C3 fracture was present in 25 patients (83.3%), and type C1 and C2 fractures were present in 2 (6.7%) and 3 (10.0%) patients, respectively. Nine fractures (30.0%) were open. Hybrid external fixation was used for all fractures. All fractures were united; clinical healing was achieved by a mean of 18.1 ± 2.2 weeks postoperatively and radiologic healing at a mean of 18.9 ± 1.9 weeks. The fixator was removed at a mean of 20.4 ± 2.0 weeks postoperatively. At a mean follow-up point of 13.4 ± 2.6 months, the mean modified Mazur ankle score was 84.6 ± 10.4. It was not associated with wound classification (p = .256). The most commonly seen complication was ankle osteoarthritis (17 patients; 56.7%); however, it was mild in >50.0% of the affected patients. In conclusion, using hybrid external fixation for type C tibial plafond fractures resulted in good outcomes. However, this should be investigated further in studies with a higher level of evidence. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Arthroscopically assisted treatment of lateral tibial plateau fractures in skiers: use of a cannulated reduction system.

    PubMed

    Holzach, P; Matter, P; Minter, J

    1994-08-01

    A prospective study was performed on 16 patients with lateral tibial plateau fractures. All injuries were associated with alpine or cross-country skiing. Included in the study were those patients with an articular surface depression of > or = 2 mm with radiographic findings consistent with the AO/ASIF classification of tibial plateau fractures (41 B2.2/B3.1). A combined procedure was performed with arthroscopic visualization of the knee joint and utilization of a cannulated plateau elevator. All fractures were reduced with this device with subsequent autogenous bone graft and, when indicated, transverse cancellous lag screw fixation. Follow-up was 1-6.5 years for the 16 patients, with all but two reporting resumption of activity to preinjury levels.

  4. Management of open tibial fractures – a regional experience

    PubMed Central

    Townley, WA; Nguyen, DQA; Rooker, JC; Dickson, JK; Goroszeniuk, DZ; Khan, MS; Camp, D

    2010-01-01

    INTRODUCTION The treatment of soft-tissue injuries associated with tibial diaphyseal fractures presents a clinical challenge that is best managed by a combined plastic and orthopaedic surgery approach. The current study was undertaken to assess early treatment outcomes and burden of service provision across five regional plastic surgery units in the South-West of England. SUBJECTS AND METHODS We conducted a prospective 6-month audit of open tibial diaphyseal fracture management in five plastic surgery units (Bristol, Exeter, Plymouth, Salisbury, Swansea) with a collective catchment of 9.2 million people. Detailed data were collected on patient demographics, injury pattern, surgical management and outcome followed to discharge. RESULTS The study group consisted of 55 patients (40 male, 15 female). Twenty-two patients presented directly to the emergency department at the specialist hospital (primary group), 33 patients were initially managed at a local hospital (tertiary group). The mean time from injury to soft tissue cover was significantly less (P < 0.001) in the primary group (3.6 ± 0.8 days) than the tertiary group (10.8 ± 2.2 days), principally due to a delay in referral in the latter group (5.4 ±1.7 days). Cover was achieved with 39 flaps (19 free, 20 local), eight split skin grafts. Nine wounds closed directly or by secondary intention. There were 11 early complications (20%) including one flap failure and four infections. The overall mean length of stay was 17.5 ± 2.8 days. CONCLUSIONS Multidisciplinary management of severe open tibial diaphyseal may not be feasible at presentation of injury depending on local hospital specialist services available. Our results highlight the need for robust assessment, triage and senior orthopaedic review in the early post-injury phase. However, broader improvements in the management of lower limb trauma will additionally require further development of combined specialist trauma centres. PMID:21047449

  5. Temporary Stabilization with External Fixator in 'Tripolar' Configuration in Two Steps Treatment of Tibial Pilon Fractures.

    PubMed

    Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè

    2016-01-01

    The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation. Temporary stabilization with external fixator in 'tripolar' configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases.

  6. [Treatment of complex tibial plateau fractures with bilateral locking plate and bone graft].

    PubMed

    Yan, Ying-Jie; Cheng, Zhan-Wei; Feng, Kai; Yan, Shao-Hua

    2012-07-01

    To explore the effective methods for the treatment of complex tibial plateau fractures. From May 2008 to April 2011, 28 patients with complex tibial plateau fractures were treated indirect reduction techniques, bilateral locking plate fixation combined with autologous bone grafts. There were 21 males and 7 females, with an average age of 43 years ranging from 21 to 65. There were 11 cases in Schatzker type V, 17 in VI. The effect was evaluated by Rasmussen standard on clinical and radiological. All patients were followed-up for 7 to 36 months (averaged of 21.5 months). Healing time of fracture was from 3 to 8 months (averaged 5.5 months). The results of Rasmussen scores in clinical was 4.50 +/- 1.32 in pain, 4.32 +/- 1.63 in walking ability, 4.07 +/- 1.34 in knee activity, 4.78 +/- 1.27 in stability of the knee, 4.85 +/- 1.12 in stretch knee; the results in radiation was 5.07 +/- 0.92 in articular surface collapse, 5.00 +/- 0.98 in platform widened, 5.14 +/- 0.85 in knee external varus. The effect result was excellent in 8 cases, good in 15, fair in 3 and poor in 2. The key for the treatment of complex tibial plateau fractures was to fully assess the damage as much as possible to protect the soft tissue, select the appropriate timing of surgery and surgical incision, application of indirect reduction techniques, limited incision and effective internal fixation to restore joint surface smooth and good limb alignment, early exercise, in order to achieve maximum recovery of joint function.

  7. Section modulus is the optimum geometric predictor for stress fractures and medial tibial stress syndrome in both male and female athletes.

    PubMed

    Franklyn, Melanie; Oakes, Barry; Field, Bruce; Wells, Peter; Morgan, David

    2008-06-01

    Various tibial dimensions and geometric parameters have been linked to stress fractures in athletes and military recruits, but many mechanical parameters have still not been investigated. Sedentary people, athletes with medial tibial stress syndrome, and athletes with stress fractures have smaller tibial geometric dimensions and parameters than do uninjured athletes. Cohort study; Level of evidence, 3. Using a total of 88 subjects, male and female patients with either a tibial stress fracture or medial tibial stress syndrome were compared with both uninjured aerobically active controls and uninjured sedentary controls. Tibial scout radiographs and cross-sectional computed tomography images of all subjects were scanned at the junction of the midthird and distal third of the tibia. Tibial dimensions were measured directly from the films; other parameters were calculated numerically. Uninjured exercising men have a greater tibial cortical cross-sectional area than do their sedentary and injured counterparts, resulting in a greater value of some other cross-sectional geometric parameters, particularly the section modulus. However, for women, the cross-sectional areas are either not different or only marginally different, and there are few tibial dimensions or geometric parameters that distinguish the uninjured exercisers from the sedentary and injured subjects. In women, the main difference between the groups was the distribution of cortical bone about the centroid as a result of the different values of section modulus. Last, medial tibial stress syndrome subjects had smaller tibial cross-sectional dimensions than did their uninjured exercising counterparts, suggesting that medial tibial stress syndrome is not just a soft-tissue injury but also a bony injury. The results show that in men, the cross-sectional area and the section modulus are the key parameters in the tibia to distinguish exercise and injury status, whereas for women, it is the section modulus only.

  8. Surgical treatment of a proximal diaphyseal tibial deformity associated with partial caudal and cranial cruciate ligament deficiency and patella baja.

    PubMed

    Vincenti, S; Knell, S; Pozzi, A

    2017-04-01

    Caudal cruciate ligament injury can be a complication following tibial plateau leveling osteotomy (TPLO) (Slocum und Slocum, 1993) especially if the post-operative Tibial Plateau Angle (TPA) is less than 5 degree. We describe a case of negative TPA associated with partial cranial and caudal ligament rupture treated with a center of rotation of angulation (CORA) based cranial tibial opening wedge osteotomy and tibial tuberosity transposition. A 13 kg, mixed breed dog was presented for right pelvic limb lameness. Radiographically a bilateral patella baja and a malformed tibia tuberosity along with a bilateral TPA of -8 degree were detected. Arthroscopically a partial rupture of the cranial and caudal cruciate ligaments were found. A cranial tibial opening wedge osteotomy of 23 degree and a fibular ostectomy were performed. The osteotomy was fixed with a 8 holes ALPS 9 (KYON, Switzerland) and a 3-holes 2.0mm UniLock plate (Synthes, Switzerland). Then a proximal tibial tuberosity transposition of 10mm was performed and fixed with a pin and tension band construct. The postoperative TPA was 15 degree. The radiographic controls at 6, 10 weeks, 6 months and 1 year after surgery revealed an unchanged position of the implants and progressive healing of the osteotomies. At the 6 and 12 months recheck evaluation the dog had no evidence of lameness or stifle pain and radiographs revealed complete healing of the osteotomy site and no implant failure. The diaphyseal CORA based osteotomy allowed accurate correction of a proximal tibial deformity associated with negative TPA.

  9. Proximal tibia stress fracture with Osteoarthritis of knee − Radiological and functional analysis of one stage TKA with long stem

    PubMed Central

    Soundarrajan, Dhanasekaran; Rajkumar, Natesan; Dhanasekararaja, Palanisamy; Rajasekaran, Shanmuganathan

    2018-01-01

    Introduction: Proximal tibia stress fractures with knee osteoarthritis pose a challenging situation. We evaluated the radiological and functional outcome of one-stage total knee arthroplasty (TKA) and long stem for patients with varied grades of knee arthritis and proximal tibia stress fractures.  Methods: We analysed 20 patients from April 2012 to March 2017 with proximal tibia stress fractures associated with knee osteoarthritis of varied grades. Out of 20 patients, five were acute fresh fractures. The mean age was 64 years (range, 52–78) which includes three men and 17 women. Previous surgery in the same limb, rheumatoid arthritis, valgus deformity were excluded. All patients were treated with posterior stabilised TKA with long stem, of which, four patients had screw augmentation for medial tibial bone defect and two patients with malunited fracture at stress fracture site required osteotomy, plating and bone grafting. Two patients had two level stress fracture of tibia in the same leg. Results: The mean follow-up period was 28 (range, 6–60) months. The mean tibiofemoral angle improved from 18.27° varus to 1.8° valgus. The mean knee society score improved from 21.9 (range, −10 to 45) to 82.8 (range, 15–99) [p < 0.05]. The mean Knee Society functional score improved from 15.5 (range, −10 to 40) to 76.8 (range, 10–100) [p < 0.05]. All fractures got united at the last follow-up. One patient had infection and wound dehiscence at six months for which debridement done and had poor functional outcome. Conclusion: TKA with long stem gives excellent outcome, irrespective of severity of arthritis associated with stress fracture. By restoring limb alignment and bypassing the fracture site, it facilitates fracture healing. Early detection and prompt intervention is necessary to prevent the progression to recalcitrant non-union or malunion. PMID:29667926

  10. Tibial plateau fracture after anterior cruciate ligament reconstruction: Role of the interference screw resorption in the stress riser effect.

    PubMed

    Thaunat, Mathieu; Nourissat, Geoffroy; Gaudin, Pascal; Beaufils, Philippe

    2006-06-01

    We report a case of tibial plateau fracture after previous anterior cruciate ligament (ACL) reconstruction using patellar tendon autograft and bioabsorbable screws 4 years previously. The fracture occurred through the tibial tunnel. The interference screw had undergone complete resorption and the tunnel widening had increased. The resorption of the interference screw did not simultaneously promote and foster the growth of surrounding bone tissue. Therefore, the area of reactive tissue left by the screw resorption in an enlarged bone tunnel may lead to vulnerability of the tibial plateau. Stress risers would occur following ACL reconstruction if either resorption is not complete or bony integration is not complete.

  11. The Applications of Finite Element Analysis in Proximal Humeral Fractures.

    PubMed

    Ye, Yongyu; You, Wei; Zhu, Weimin; Cui, Jiaming; Chen, Kang; Wang, Daping

    2017-01-01

    Proximal humeral fractures are common and most challenging, due to the complexity of the glenohumeral joint, especially in the geriatric population with impacted fractures, that the development of implants continues because currently the problems with their fixation are not solved. Pre-, intra-, and postoperative assessments are crucial in management of those patients. Finite element analysis, as one of the valuable tools, has been implemented as an effective and noninvasive method to analyze proximal humeral fractures, providing solid evidence for management of troublesome patients. However, no review article about the applications and effects of finite element analysis in assessing proximal humeral fractures has been reported yet. This review article summarized the applications, contribution, and clinical significance of finite element analysis in assessing proximal humeral fractures. Furthermore, the limitations of finite element analysis, the difficulties of more realistic simulation, and the validation and also the creation of validated FE models were discussed. We concluded that although some advancements in proximal humeral fractures researches have been made by using finite element analysis, utility of this powerful tool for routine clinical management and adequate simulation requires more state-of-the-art studies to provide evidence and bases.

  12. Can tibial plateau fractures be reduced and stabilised through an angiosome-sparing antero-lateral approach?

    PubMed

    Solomon, Lucian B; Boopalan, P R J V C; Chakrabarty, Adhiraj; Callary, Stuart A

    2014-04-01

    Tibial plateau fractures (TPFs) are an independent, non-modifiable risk factor for surgical site infections (SSIs). Current antero-lateral approaches to the knee dissect through the anterior tibial angiosome (ATA), which may contribute to a higher rate of SSIs. The aim of this study was to develop an angiosome-sparing antero-lateral approach to allow reduction and fixation of lateral TPFs and to investigate its feasibility in a consecutive cohort. Twenty cadaveric knees were dissected to define the position of the vessels supplying the ATA from the lateral tibial condyle to the skin perforators. Based on these results, an angiosome-sparing surgical approach to treat lateral TPFs was developed. Fifteen consecutive patients were subsequently treated through this approach. Clinical outcomes included assessment of SSI and Lysholm score. Fracture healing and stability were assessed using the Rasmussen score and radiostereometric analysis (RSA). At the latest follow-up between 1 and 4 years, there was no report of SSI. Nine patients (60%) had good or excellent Lysholm scores. The mean Rasmussen score at final follow-up was 17 (median 18, range 14-18) with 10 patients (66%) graded as excellent. Fracture fragment migration measured using RSA was below 2mm in all cases. This study has demonstrated that an angiosome-sparing antero-lateral approach to the lateral tibial plateau is feasible. Adequate stability of these fracture types was achieved by positioning a buttress plate away from the bone and superficial to the regional fascial layer as an 'internal-external fixator'. The angiosome-sparing approach developed was able to be used in a prospective cohort and the clinical results to date are encouraging. Future clinical studies need to investigate the potential benefits of this surgical approach when compared with the previously described antero-lateral approaches. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  13. The influence of local bone quality on fracture pattern in proximal humerus fractures.

    PubMed

    Mazzucchelli, Ruben A; Jenny, Katharina; Zdravkovic, Vilijam; Erhardt, Johannes B; Jost, Bernhard; Spross, Christian

    2018-02-01

    Bone mineral density and fracture morphology are widely discussed and relevant factors when considering the different treatment options for proximal humerus fractures. It was the aim of this study to investigate the influence of local bone quality on fracture patterns of the Neer classification as well as on fracture impaction angle in these injuries. All acute, isolated and non-pathological proximal humerus fractures admitted to our emergency department were included. The fractures were classified according to Neer and the humeral head impaction angle was measured. Local bone quality was assessed using the Deltoid Tuberosity Index (DTI). The distribution between DTI and fracture pattern was analysed. 191 proximal humerus fractures were included (61 men, mean age 59 years; 130 women, mean age 69.5). 77 fractures (40%) were classified as one-part, 72 (38%) were two-part, 24 (13%) were three- and four-part and 18 (9%) were fracture dislocations. 30 fractures (16%) were varus impacted, whereas 45 fractures (24%) were classified as valgus impacted. The mean DTI was 1.48. Valgus impaction significantly correlated with good bone quality (DTI ≥ 1.4; p = 0.047) whereas no such statistical significance was found for the Neer fracture types. We found that valgus impaction significantly depended on good bone quality. However, neither varus impaction nor any of the Neer fracture types correlated with bone quality. We conclude that the better bone quality of valgus impacted fractures may be a reason for their historically benign amenability to ORIF. On the other hand, good local bone quality does not prevent fracture comminution. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Soft tissue management of children's open tibial fractures – a review of seventy children over twenty years

    PubMed Central

    Rao, P; Schaverien, MV; Stewart, KJ

    2010-01-01

    INTRODUCTION The management of open tibial fractures in children represents a unique reconstructive challenge. The aim of the study was to evaluate the management of paediatric open tibial fractures with particular regard to soft tissue management. PATIENTS AND METHODS A retrospective case-note analysis was performed for all children presenting with an open tibial fracture at a single institution over a 20-year period for 1985 to 2005. RESULTS Seventy children were reviewed of whom 41 were males and 29 females. Overall, 91% (n = 64) of children suffered their injury as a result of a vehicle-related injury. The severity of the fracture with respect to the Gustilo classification was: Grade I, 42% (n = 29); Grade II, 24% (n = 17); Grade III, 34% (n = 24; 7 Grade 3a, 16 Grade 3b, 1 Grade 3c). The majority of children were treated with external fixation and conservative measures, with a mean hospital in-patient stay of 13.3 days. Soft tissue cover was provided by plastic surgeons in 31% of all cases. Four cases of superficial wound infection occurred (6%), one case of osteomyelitis and one case of flap failure. The limb salvage was greater than 98%. CONCLUSIONS In this series, complications were associated with delayed involvement of plastic surgeons. Retrospective analysis has shown a decreased incidence of open tibial fractures which is reported in similar studies. Gustilo grade was found to correlate with length of hospital admission and plastic surgery intervention. We advocate, when feasible, the use of local fas-ciocutaneous flaps (such as distally based fasciocutaneous and adipofascial flaps), which showed a low complication rate in children. PMID:20501017

  15. [Minimally invasive percutaneous plate osteosynthesis versus open reduction and internal fixation for distal tibial fractures in adults: a meta-analysis].

    PubMed

    Zhang, Qing-xi; Gao, Fu-qiang; Sun, Wei; Wang, Yun-ting; Yang, Yu-run; Li, Zirong

    2015-08-01

    To perform a meta-analysis on clinical outcomes of minimally invasive percutaneous plate osteosynthesis (MIPPO) or open reduction and internal fixation (ORIF) for distal tibial fractures in adults. Pubmed database (from 1968 to March 2014), Cochrane library and CNKI database (from 1998 to March 2014) were searched. Case-control study on minimally invasive percutaneous plate osteosynthesis (MIPPO) or open reduction and internal fixation (ORIF) for distal tibial fractures in adults were chosen,and postoperative infection, operative time, blood loss, fracture nonunion rate, delayed union,fracture malunion rate were seen as evaluation index for meta analysis. The system review was performed using the method recommended by the Cochrane Collaboration. Totally 5 studies (366 patients) were enrolled. Meta-analysis showed that there were significant meaning in postoperative infection between MIPPO and ORIF [OR = 0.23,95% CI (0.06,0.92), P = 0.04]; fracture nonunion rate in MIPPO was lower than in ORIF group [OR = 0.16, 95% CI (0.03,0.76), P = 0.02]; operative time in MIPPO was shorter than in ORIF group, and had significant difference [MD = -14.42, 95% CI (-27.79, -1.05), P < 0.05]; blood loss in MIPPO was less than in ORIF group [MD= -87.17,95%CI (-99.20, -75.15), P < 0.05]; there was no obviously meaning in delayed union between two groups. For distal tibial fractures in adults, MIPPO has, advantages of short operative time, less blood loss, lower incidence of infection and fracture non-uniom, but with high fracture malunion rate. MIPPO for distal tibial fractures in adults is better than ORIF, and the best treatment should choose according to patient's condition.

  16. Tibial tunnel aperture location during single-bundle posterior cruciate ligament reconstruction: comparison of tibial guide positions.

    PubMed

    Shin, Young-Soo; Han, Seung-Beom; Hwang, Yeok-Ku; Suh, Dong-Won; Lee, Dae-Hee

    2015-05-01

    We aimed to compare posterior cruciate ligament (PCL) tibial tunnel location after tibial guide insertion medial (between the PCL remnant and the medial femoral condyle) and lateral (between the PCL remnant and the anterior cruciate ligament) to the PCL stump as determined by in vivo 3-dimensional computed tomography (3D-CT). Tibial tunnel aperture location was analyzed by immediate postoperative in vivo CT in 66 patients who underwent single-bundle PCL reconstruction, 31 by over-the-PCL and 35 by under-the-PCL tibial guide insertion techniques. Tibial tunnel positions were measured in the medial to lateral and proximal to distal directions of the posterior proximal tibia. The center of the tibial tunnel aperture was located more laterally (by 2.7 mm) in the over-the-PCL group than in the under-the-PCL group (P = .040) and by a relative percentage (absolute value/tibial width) of 3.2% (P = .031). Tibial tunnel positions in the proximal to distal direction, determined by absolute value and relative percentage, were similar in the 2 groups. Tibial tunnel apertures were located more laterally after lateral-to-the-PCL tibial guide insertion than after medial-to-the-PCL tibial guide insertion. There was, however, no significant difference between these techniques in distance from the joint line to the tibial tunnel aperture. Insertion lateral to the PCL stump may result in better placement of the PCL in its anatomic footprint. Level III, retrospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. 3D printing-assisted osteotomy treatment for the malunion of lateral tibial plateau fracture.

    PubMed

    Yang, Peng; Du, Di; Zhou, Zhibin; Lu, Nan; Fu, Qiang; Ma, Jun; Zhao, Liangyu; Chen, Aimin

    2016-12-01

    Osteotomy and internal fixation are usually the most effective way to treat the malunion of lateral tibial plateau fractures, and the accuracy of the osteotomy is still a challenge for surgeons. This is a report of a series of prospectively study of osteotomy treatment for the malunion of lateral plateau fractures with the aid of 3D printing technology. A total of 7 patients with malunion of lateral tibial plateau fractures were enrolled in the study between September 2012 to September 2014 and completed follow up. CT image data were used for 3D reconstruction, and individually 3D printed models were used for accurate measurements and detail osteotomy procedures planning. Under the premeditated operation plan, the osteotomy operations were performed. Patients were invited for follow-up examinations at 2 and 6 weeks and then at intervals of 6 to 8 weeks until 12 months or more. Mean age of the patients was 44 years (range 30-52 years), 3 cases were result of fall injuries, 2 were traffic accidents and 2 were sports injuries. Among the cases, one accompanied with craniocerebra trauma, one with pelvic fracture, one accompanied with both. According to the Schatzker Tibial Plateau classification, the original fracture type were 3 type I, 1 type II and 3 type III. The lateral tibial plateau collapse ranges from 4 mm-12mm, with an average of 9.4mm. All the operations were successfully completed, the average operation time was 77.1min (range 70-90 min), the average intraoperative blood loss was 121.4ml (range 90-180ml), the mean follow-up time was 14.4 months (range 12-18 months), and the average healing time of the osteotomy fragments was 12 weeks (range 11-13 weeks). The difference between preoperative and postoperative Rasmussen scores were statistically significant (P<0.05). All the patients were obtained functional recovery, with no complications. 3D printing technology is helpful to accurately design osteotomy operation, reduce the risk of postoperative deformity

  18. Do clinical outcomes correlate with bone density after open reduction and internal fixation of tibial plateau fractures.

    PubMed

    Gausden, Elizabeth; Garner, Matthew R; Fabricant, Peter D; Warner, Stephen J; Shaffer, Andre D; Lorich, Dean G

    2017-06-01

    The operative management of tibial plateau fractures in elderly patients has historically led to inconsistent results, and these clinical outcomes were thought to be associated with poor bone quality often in elderly patients. The goal of this study was to investigate the relationship between bone density and subjective clinical outcome scores after open reduction and internal fixation of tibial plateau fractures. This is a retrospective cohort study from a single-surgeon conducted at an Academic, Level 1 Trauma Center. A preoperative computed tomography (CT) scan was obtained for all patients. Bone density of the distal femur was quantified with Hounsfield units (HU) as measured on axial CT scans. Inter-rater reliability of HU measurements was assessed using interclass correlation coefficients. Regression models controlling for age were used to identify relationships between bone density (HU) and the following variables: articular subsidence and 1-year subjective clinical outcomes scores [Knee Outcome Survey Activities of Daily Living Scale (KOS-ADLS), and Short-Form-36 (SF-36) physical and mental component scores (PCS, MCS)]. Sixty-one patients with a mean age of 59.3 years (range 27-85 years) and a minimum of 12 months of clinical follow-up were included in the study. The majority of the fractures (32 of 61) were classified as Schatzker II tibial plateau fractures, and there were 13 Schatzker V fractures, 11 Schatzker VI fractures, 2 Schatzker IV fractures and 1 Schatzker 1 fracture. HU measurements demonstrated an almost perfect inter-observer reliability (ICC = 0.97). Age was negatively correlated with HU measurements (r = -0.51, p < 0.001), and using a geriatric cut-off of 65 years of age, the geriatric group had a lower mean HU compared to the non-geriatric group (78.2 versus 114.8, p = 0.018). There was no significant relationship between bone quality, as assessed by distal femoral HU, and any subjective clinical outcome score. Inferior

  19. Outcome of limb reconstruction system in open tibial diaphyseal fractures.

    PubMed

    Ajmera, Anand; Verma, Ankit; Agrawal, Mukul; Jain, Saurabh; Mukherjee, Arunangshu

    2015-01-01

    Management of open tibial diaphyseal fractures with bone loss is a matter of debate. The treatment options range from external fixators, nailing, ring fixators or grafting with or without plastic reconstruction. All the procedures have their own set of complications, like acute docking problems, shortening, difficulty in soft tissue management, chronic infection, increased morbidity, multiple surgeries, longer hospital stay, mal union, nonunion and higher patient dissatisfaction. We evaluated the outcome of the limb reconstruction system (LRS) in the treatment of open fractures of tibial diaphysis with bone loss as a definative mode of treatment to achieve union, as well as limb lengthening, simultaneously. Thirty open fractures of tibial diaphysis with bone loss of at least 4 cm or more with a mean age 32.5 years were treated by using the LRS after debridement. Distraction osteogenesis at rate of 1 mm/day was done away from the fracture site to maintain the limb length. On the approximation of fracture ends, the dynamized LRS was left for further 15-20 weeks and patient was mobilized with weight bearing to achieve union. Functional assessment was done by Association for the Study and Application of the Methods of Illizarov (ASAMI) criteria. Mean followup period was 15 months. The mean bone loss was 5.5 cm (range 4-9 cm). The mean duration of bone transport was 13 weeks (range 8-30 weeks) with a mean time for LRS in place was 44 weeks (range 24-51 weeks). The mean implant index was 56.4 days/cm. Mean union time was 52 weeks (range 31-60 weeks) with mean union index of 74.5 days/cm. Bony results as per the ASAMI scoring were excellent in 76% (19/25), good in 12% (3/25) and fair in 4% (1/25) with union in all except 2 patients, which showed poor results (8%) with only 2 patients having leg length discrepancy more than 2.5 cm. Functional results were excellent in 84% (21/25), good in 8% (2/25), fair in 8% (2/25). Pin tract infection was seen in 5 cases, out of which 4

  20. Arthroscopic Management of Tibial Spine Avulsion Fractures: Principles and Techniques.

    PubMed

    Strauss, Eric J; Kaplan, Daniel James; Weinberg, Maxwell E; Egol, Jonathan; Jazrawi, Laith M

    2018-05-15

    Tibial spine fractures are uncommon injuries affecting the insertion of the anterior cruciate ligament on the tibia. They typically occur in skeletally immature patients aged 8 to 14 years and result from hyperextension of the knee with a valgus or rotational force. Diagnosis is based on history, physical examination, and standard radiographs. The use of MRI can identify entrapped soft tissue that may prevent reduction. Open or arthroscopic repair is indicated in patients with partially displaced fractures (>5 mm) with one third to one half of the avulsed fragment elevated, in patients who have undergone unsuccessful nonsurgical reduction and long leg casting or bracing, and in patients with completely displaced fractures. Arthroscopy offers reduced invasiveness and decreased morbidity. Suture fixation and screw fixation have produced successful results. Suture fixation can eliminate the risk of fracture fragment comminution during screw insertion, the risk of neurovascular injury, and the need for hardware removal. Suture fixation is ideal in cases in which existing comminution prevents screw fixation.

  1. [Comparison of effect between early and delayed in primary intramedullary nailing combined with locked plate fixation for the treatment of multi-segments tibial fractures of type].

    PubMed

    Gao, Wei-qiang; Hu, Jiang-hai; Gu, Zhu-chao; Zhang, Huai-xian; Min, Peng; Zhang, Lin-jun; Yu, Wen-wen; Wang, Guang-lin

    2015-02-01

    locked plating does not significantly increase the postoperative incidence of soft tissue complications for patients. The early and delayed primary intramedullary nailing and locked plating for treatment of AO/ASIF-42C2 proximal third tibial fractures can get similar curative effect.

  2. Foal Fractures: Osteochondral Fragmentation, Proximal Sesamoid Bone Fractures/Sesamoiditis, and Distal Phalanx Fractures.

    PubMed

    Reesink, Heidi L

    2017-08-01

    Foals are susceptible to many of the same types of fractures as adult horses, often secondary to external sources of trauma. In addition, some types of fractures are specific to foals and occur routinely in horses under 1 year of age. These foal-specific fractures may be due to the unique musculoskeletal properties of the developing animal and may present with distinct clinical signs. Treatment plans and prognoses are tailored specifically to young animals. Common fractures not affecting the long bones in foals are discussed in this article, including osteochondral fragmentation, proximal sesamoid bone fractures/sesamoiditis, and distal phalanx fractures. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Distal tibial fractures are a poorly recognised complication with fibula free flaps.

    PubMed

    Durst, A; Clibbon, J; Davis, B

    2015-09-01

    The fibula free flap is ideal for complex jaw reconstructions, with low reported donor and flap morbidity. We discuss a distal tibial stress fracture two months following a vascularised fibula free flap procedure. Despite being an unrecognised complication, a literature review produced 13 previous cases; only two were reported in the reconstructive surgery literature, with the most recent claiming to be the first. The majority of these studies treated this fracture non-operatively; none reported their patient follow-up. Each case presented with ipsilateral leg pain, which has been cited as an early donor site morbidity in as many as 40% of fibula free flap cases. It is known that the fibula absorbs at least 15% of leg load on weight bearing. Studies have shown severe valgus deformities in up to 25% of patients with fibulectomies. We treated our patient operatively, first correcting his worsening valgus deformity with an external fixator, then reinforcing his healed fracture with a long distal tibial plate. We believe that this complication is underreported, unexpected and not mentioned during the consenting process. By highlighting the management of our case and the literature, we aim to increase awareness (and thus further reporting and appropriate management) of this debilitating complication.

  4. Treatment of open tibial fracture with bone defect caused by high velocity missiles: a case report.

    PubMed

    Golubović, Zoran; Vukajinović, Zoran; Stojiljković, Predrag; Golubović, Ivan; Visnjić, Aleksandar; Radovanović, Zoran; Najman, Stevo

    2013-01-01

    Tibia fracture caused by high velocity missiles is mostly comminuted and followed by bone defect which makes their healing process extremely difficult and prone to numerous complications. A 34-year-old male was wounded at close range by a semi-automatic gun missile. He was wounded in the distal area of the left tibia and suffered a massive defect of the bone and soft tissue. After the primary treatment of the wound, the fracture was stabilized with an external fixator type Mitkovic, with convergent orientation of the pins. The wound in the medial region of the tibia was closed with the secondary stitch, whereas the wound in the lateral area was closed with the skin transplant after Thiersch. Due to massive bone defect in the area of the rifle-missile wound six months after injury, a medical team placed a reconstructive external skeletal fixator type Mitkovic and performed corticotomy in the proximal metaphyseal area of the tibia. By the method of bone transport (distractive osteogenesis), the bone defect of the tibia was replaced. After the fracture healing seven months from the secondary surgery, the fixator was removed and the patient was referred to physical therapy. Surgical treatment of wounds, external fixation, performing necessary debridement, adequate antibiotic treatment and soft and bone tissue reconstruction are essential in achieving good results in patients with the open tibial fracture with bone defect caused by high velocity missiles. Reconstruction of bone defect can be successfully treated by reconstructive external fixator Mitkovic.

  5. Ball-joint versus single monolateral external fixators for definitive treatment of tibial shaft fractures.

    PubMed

    Beltsios, Michail; Mavrogenis, Andreas F; Savvidou, Olga D; Karamanis, Eirineos; Kokkalis, Zinon T; Papagelopoulos, Panayiotis J

    2014-07-01

    To compare modular monolateral external fixators with single monolateral external fixators for the treatment of open and complex tibial shaft fractures, to determine the optimal construct for fracture union. A total of 223 tibial shaft fractures in 212 patients were treated with a monolateral external fixator from 2005 to 2011; 112 fractures were treated with a modular external fixator with ball-joints (group A), and 111 fractures were treated with a single external fixator without ball-joints (group B). The mean follow-up was 2.9 years. We retrospectively evaluated the operative time for fracture reduction with the external fixator, pain and range of motion of the knee and ankle joints, time to union, rate of malunion, reoperations and revisions of the external fixators, and complications. The time for fracture reduction was statistically higher in group B; the rate of union was statistically higher in group B; the rate of nonunion was statistically higher in group A; the mean time to union was statistically higher in group A; the rate of reoperations was statistically higher in group A; and the rate of revision of the external fixator was statistically higher in group A. Pain, range of motion of the knee and ankle joints, rates of delayed union, malunion and complications were similar. Although modular external fixators are associated with faster intraoperative fracture reduction with the external fixator, single external fixators are associated with significantly better rates of union and reoperations; the rates of delayed union, malunion and complications are similar.

  6. [Structural changes in the tibial bones from an excessive load].

    PubMed

    Moshiashvili, B I

    1977-10-01

    80 cases of pathological reconstruction of the tibia in young men at the age of 18--20 are described. The pathology developed as a result of intense regular physical exercise. In 53 patients the process was localized in the upper third of the tibia, in 20--in the middle third and in 7--in the lower third of the bone. In 6 cases the fracture of the tibial proximal metaphysis happened against the background of pathological reconstruction of the tibia; 3 of them sustained simultaneously a fracture of the fibular head. Some recommendations of practical importance are suggested.

  7. Interlocking Nailing Versus Plating in Tibial Shaft Fractures in Adults: A Comparative Study.

    PubMed

    Mukherjee, Sagnik; Arambam, Mahendra Singh; Waikhom, Sanjib; Santosha; Masatwar, Pranav Vitthal; Maske, Rohan Gautam

    2017-04-01

    Tibial diaphyseal fractures are the commonest long bone fractures in adults, most commonly managed by intramedullary interlocking nailing. However, several meta-analysis show that locking plate osteosynthesis is equally effective in managing tibial diaphyseal fractures and are associated with less number of complications. To compare the results of fixation of tibial fractures following plating and nailing in terms of union, patient satisfaction and complications. A hospital based non randomized clinical trial was performed from September 2013 to August 2016 where closed or open diaphyseal or metaphyseo- diaphyseal fractures of the tibia (closed or open Gustilo Anderson type 1 through 3B) were included. Simple sequential allocation was used for allotting the patients to two groups, one for interlocking nailing and other for plating. The patients were followed up for clinical, radiographic and functional results. Forty patients with 41 involved limbs completed follow up for one year. The duration of surgery and average blood loss during surgery was 75.45±3.03 minutes and 165.00±5.31 ml respectively in case of nailing and 85.05±2.54 minutes and184.29±5.33 ml respectively in case of plating and their difference was statistically significant. In our study union was achieved in less than 20 weeks in 29 (70.8%) of the patients and 25-30 weeks in nine (22%) cases. The average time of union in our study was 19.55±0.69 weeks in case of interlocking nailing and 20.38±1.39 weeks in case of plating and there was no statistically significant difference between the two. However, there is statistically significant difference in the functional score in between the two groups in terms of Lower Extremity Functional Score (LEFS). Delayed union in one case of nailing and two cases of plating, valgus malunion in one case of nailing and joint stiffness in two cases each of nailing and plating were the major complications observed. There was no difference between the two modalities

  8. Interlocking Nailing Versus Plating in Tibial Shaft Fractures in Adults: A Comparative Study

    PubMed Central

    Arambam, Mahendra Singh; Waikhom, Sanjib; Santosha; Masatwar, Pranav Vitthal; Maske, Rohan Gautam

    2017-01-01

    Introduction Tibial diaphyseal fractures are the commonest long bone fractures in adults, most commonly managed by intramedullary interlocking nailing. However, several meta-analysis show that locking plate osteosynthesis is equally effective in managing tibial diaphyseal fractures and are associated with less number of complications. Aim To compare the results of fixation of tibial fractures following plating and nailing in terms of union, patient satisfaction and complications. Materials and Methods A hospital based non randomized clinical trial was performed from September 2013 to August 2016 where closed or open diaphyseal or metaphyseo- diaphyseal fractures of the tibia (closed or open Gustilo Anderson type 1 through 3B) were included. Simple sequential allocation was used for allotting the patients to two groups, one for interlocking nailing and other for plating. The patients were followed up for clinical, radiographic and functional results. Results Forty patients with 41 involved limbs completed follow up for one year. The duration of surgery and average blood loss during surgery was 75.45±3.03 minutes and 165.00±5.31 ml respectively in case of nailing and 85.05±2.54 minutes and184.29±5.33 ml respectively in case of plating and their difference was statistically significant. In our study union was achieved in less than 20 weeks in 29 (70.8%) of the patients and 25-30 weeks in nine (22%) cases. The average time of union in our study was 19.55±0.69 weeks in case of interlocking nailing and 20.38±1.39 weeks in case of plating and there was no statistically significant difference between the two. However, there is statistically significant difference in the functional score in between the two groups in terms of Lower Extremity Functional Score (LEFS). Delayed union in one case of nailing and two cases of plating, valgus malunion in one case of nailing and joint stiffness in two cases each of nailing and plating were the major complications observed

  9. Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate).

    PubMed

    Biazzo, Alessio; Cardile, Carlo; Brunelli, Luca; Ragni, Paolo; Clementi, Daniele

    2017-04-28

    The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (OrthofixR, Bussolengo,Verona, Italy), for the treatment of displaced 2- and 3-part fractures of the proximal humerus. We retrospectively reviewed 55 patients with proximal humerus fractures, who underwent osteosynthesis with Contours Proximal Humerus Plate from December 2011 to March 2015. We had 21 patients with 2-part fractures and with an average age of 67.1 years and 34 patients with 3-part fractures, with average age of 63.6 years. The average union time was 3 months. The mean Constant score was 67 for 2-part fracture group and 64.9 for 3-part fracture group. The difference was not statistically significant (p = 0.18). The overall complication rate was 14.5 %. Six patients underwent additional surgery (10.9%). The most frequent major complication was secondary loss of reduction following varus collapse of the fracture (2 cases). In these patients, there was loss of medial hinge integrity due to impaction and osteoporosis. The placement of the main locking screw in the calcar area to provide inferomedial support is the rational of the Contours Proximal Humerus Plate. Osteosynthesis with Contours Proximal Humerus Plate is a safe system for treating displaced 2- and 3-part fractures of the proximal humerus, with good functional results and complication rates comparable to those reported in the literature.

  10. [Pathologic proximal femoral fractures in children in an unicameral bone cyst].

    PubMed

    Havránek, P; Pesl, T; Bartonícek, J

    2005-01-01

    Proximal femoral fractures in children are rare, pathologic fractures being extremely rare. Despite many meanings these fractures are still "unsolved" there are some definite rules for treatment of true accidental injuries. Pathologic fractures are outstanding with their extremely rare incidence. The aim of the study is to overview a large clinical material, find out the incidence of this pathologic fracture, the extent and shape of the unicameral bone cyst (UBC), specific therapeutic approach, technical problems of eventual osteosynthesis, number of reoperations and sequels. Altogether 49 children with 50 accidental and pathologic fractures of proximal part of the femur treated in the Regional Pediatric Trauma Centre of the Department of Pediatric and Trauma Surgery, 3rd Faculty of Medicine, Charles University, Prague. Retrospective and prospective study of children (0 to 15 years of age) treated with proximal femoral accidental and pathologic fractures during the 20 year period (from August 1984 to November 2004). Classification of fractures according to Delbet and Colonna. Diagnosis of bone cyst with plain X-rays, eventually CT scans. During the 20 years period (August 1984 to November 2004) 49 children with 50 proximal femoral fractures were treated in the Department. Four patients sustained a pathologic fracture through an unicameral bone cyst. Two of these latter children were treated by an open reduction and osteosynthesis with the use of the proximal femoral AO-ASIF angled-plate and two children nonoperatively using skeletal traction because of impossibility of insertion of the osteosynthetic material without a damage of the growth plate. Subsequent operations of the UBC were necessary in these two children. All four patients recovered well without sequels. Pathologic fractures in UBC are usually treated nonoperatively and the cyst itself is treated after fracture healing. Proximal femoral impairment is the exception from this rule because of weigh bearing

  11. Tibial tunnel aperture irregularity after drilling with 5 reamer designs: a qualitative micro-computed tomography analysis.

    PubMed

    Geeslin, Andrew G; Jansson, Kyle S; Wijdicks, Coen A; Chapman, Mark A; Fok, Alex S; LaPrade, Robert F

    2011-04-01

    There is limited information in the literature on comparisons of antegrade versus retrograde reaming techniques and the effect on the creation of anterior cruciate ligament (ACL) tibial tunnel entry and exit apertures. Proximal and distal apertures of ACL tibial tunnels, as created with different reamers, will be affected by type of reamer design. Controlled laboratory study. Forty skeletally mature porcine tibias with bone mineral density values comparable with a young athletic population were included in this study. Five 9-mm reamer models were used (3 antegrade: A1, smooth-bore reamer; A2, acorn-head reamer; A3, flat-head reamer; 2 retrograde: R1, retrograde acorn reamer; R2, single-blade retrograde reamer), and a new reamer was used for each tibia (8 reamer-tibia pairs per reamer model). All specimens underwent micro-computed tomography scanning, and images were reconstructed and analyzed using 3-dimensional image analysis software. Aperture rim fractures were graded on a 0-IV scale that described the proportion of the fractured aperture circumference. Specimens with incomplete apertures were also recorded. Because of the unique characteristics of various tunnels, intratunnel characteristics were observed and recorded. In sum, 1 proximal and 7 distal aperture rim fractures were found; 3, 0, and 4 distal aperture rim fractures were found with groups A1, A2, and A3, respectively. Incomplete apertures were more commonly found at the distal aperture (n = 15) than the proximal aperture (n = 8); there were no tibias with this finding at both apertures. All incomplete distal apertures occurred with the retrograde technique, and all incomplete proximal apertures occurred with the antegrade technique, most commonly with reamer design A3. An added finding of tunnel curvature at the distal aspect of the tunnel was observed in all 8 tibias with R1 reamers and 5 tibias with R2 reamers. This phenomenon was not observed in any of the tibias reamed with the antegrade technique

  12. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation.

    PubMed

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-10-01

    The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5-9 months) and 6.0 months (range: 5-8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°-150°) and 135° (range: 100°-160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.

  13. Nail or plate in the management of distal extra-articular tibial fracture, what is better? Valutation of outcomes

    PubMed Central

    Bisaccia, Michele; Cappiello, Andrea; Meccariello, Luigi; Rinonapoli, Giuseppe; Falzarano, Gabriele; Medici, Antonio; Vicente, Cristina Ibáñez; Piscitelli, Luigi; Stano, Verdiana; Bisaccia, Olga; Caraffa, Auro

    2018-01-01

    Introduction: Distal tibial fractures are the most common long bone fractures. Several studies focusing on the methods of treatment of displaced distal tibial fractures have been published. To date, locked plates, intramedullary nails and external fixation are the three most used techniques. The aim of our study was to compare intramedullary nail (IMN) and locked plate (LP) for treatment of this kind of fracture. Materials and methods: We collected data on 81 patients with distal tibial fractures (distance from the joint between 40 and 100 mm) and we divided into two groups: IMN and LP. We compared in the 2 groups the mean operation time, the mean union time, the infection rate the rate of malunion and nonunion, the full weight bearing time. Results: No patient in the two groups developed a nonunion. None of the patients obtained a fair or poor outcome. Overall 52 patients obtained an excellent result (69.3%) and 23 obtained a good result (30.6%). Discussion: Our study results indicate a superiority of IMN over LP in terms of lower rates of infections and statistically significant shorter time to full weight bearing. Whereas LP appeared to be advantageous over IMN in terms of leading to a better anatomical and fixed reductions of the fracture and a lower rate of union complications. The two treatments achieved comparable results in terms of operation time, hospital stay, union time and functional outcomes. PMID:29469802

  14. Does human immunodeficiency virus status affect early wound healing in open surgically stabilised tibial fractures?: A prospective study.

    PubMed

    Howard, N E; Phaff, M; Aird, J; Wicks, L; Rollinson, P

    2013-12-01

    We compared early post-operative rates of wound infection in HIV-positive and -negative patients presenting with open tibial fractures managed with surgical fixation. The wounds of 84 patients (85 fractures), 28 of whom were HIV positive and 56 were HIV negative, were assessed for signs of infection using the ASEPIS wound score. There were 19 women and 65 men with a mean age of 34.8 years. A total of 57 fractures (17 HIV-positive, 40 HIV-negative) treated with external fixation were also assessed using the Checkett score for pin-site infection. The remaining 28 fractures were treated with internal fixation. No significant difference in early post-operative wound infection between the two groups of patients was found (10.7% (n = 3) vs 19.6% (n = 11); relative risk (RR) 0.55 (95% confidence interval (CI) 0.17 to 1.8); p = 0.32). There was also no significant difference in pin-site infection rates (17.6% (n = 3) vs 12.5% (n = 5); RR 1.62 (95% CI 0.44 to 6.07); p = 0.47). The study does not support the hypothesis that HIV significantly increases the rate of early wound or pin-site infection in open tibial fractures. We would therefore suggest that a patient's HIV status should not alter the management of open tibial fractures in patients who have a CD4 count > 350 cells/μl.

  15. Participation in Recreational Athletics After Operative Fixation of Tibial Plateau Fractures: Predictors and Functional Outcomes of Those Getting Back in the Game

    PubMed Central

    Kugelman, David N.; Qatu, Abdullah M.; Haglin, Jack M.; Konda, Sanjit R.; Egol, Kenneth A.

    2017-01-01

    Background: Tibial plateau fractures can be devastating traumatic injuries to the knee, particularly in active athletes. Purpose/Hypothesis: The purpose of this study was to report on the return to participation in recreational athletics after operatively managed tibial plateau fractures. In addition, this study assessed factors associated with the ability to return to participation in recreational athletics after tibial plateau fractures treated with open reduction internal fixation and compared final outcomes between patients who were able to return to recreational athletics and those who could not. The hypothesis was that returning to participation in recreational athletics would be dependent on the time from surgery after operative fixation of tibial plateau fractures. Less severe injuries would be associated with a quicker return to athletics. Study Design: Case-control study; Level of evidence, 3. Methods: All tibial plateau fractures treated by 1 of 3 surgeons at a single academic institution over an 11-year period were prospectively followed. Final outcomes were evaluated using the Short Musculoskeletal Function Assessment at latest follow-up. All complications were recorded at each follow-up. Differences between the groups were compared using Student t tests for continuous variables. Chi-square analysis was used to determine whether differences between categorical variables existed. Logistic regression was performed to assess independent variables associated with returning to participation in recreational athletics. Results: A total of 169 patients who underwent operative management of their tibial plateau fracture reported participation in recreational athletics before their injury. By the 6-month time point, 48 patients (31.6%) had returned to participation in recreational athletics, and at final follow-up (mean, 15 months), 89 patients (52.4%) had returned to participation in recreational athletics. Predictors of returning to recreational athletics

  16. Compartment syndrome after tibial plateau fracture☆

    PubMed Central

    Pitta, Guilherme Benjamin Brandão; dos Santos, Thays Fernanda Avelino; dos Santos, Fernanda Thaysa Avelino; da Costa Filho, Edelson Moreira

    2014-01-01

    Fractures of the tibial plateau are relatively rare, representing around 1.2% of all fractures. The tibia, due to its subcutaneous location and poor muscle coverage, is exposed and suffers large numbers of traumas, not only fractures, but also crush injuries and severe bruising, among others, which at any given moment, could lead compartment syndrome in the patient. The case is reported of a 58-year-old patient who, following a tibial plateau fracture, presented compartment syndrome of the leg and was submitted to decompressive fasciotomy of the four right compartments. After osteosynthesis with internal fixation of the tibial plateau using an L-plate, the patient again developed compartment syndrome. PMID:26229779

  17. Percutaneous locking plates for fractures of the distal tibia: our experience and a review of the literature.

    PubMed

    Ahmad, Mudussar Abrar; Sivaraman, Alagappan; Zia, Ahmed; Rai, Amarjit; Patel, Amratlal D

    2012-02-01

    Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with medial locking plates. Eighteen patients were selected based on the fracture pattern and classified using the AO classification and stabilized with an AO medial tibial locking plate. Time to fracture union, complications, and outcomes were assessed with the American Orthopedic Foot and Ankle Society Ankle score at 12 months. Sixteen of the 18 patients achieved fracture union, with 1 patient lost to follow-up. Twelve fractures united within 24 weeks, with an average union time of 23.1 weeks. Three delayed unions, two at 28 weeks and one at 56 weeks. The average time to union was 32 weeks in the smokers and 15.3 weeks in the nonsmokers. Five of the 18 patients (27%) developed complications. One superficial wound infection, and one chronic wound infection, resulting in nonunion at 56 weeks, requiring revision. Two patients required plate removal, one after sustaining an open fracture at the proximal end of the plate 6 months after surgery (postfracture union)and the other for painful hardware. One patient had implant failure of three proximal diaphyseal locking screws at the screwhead/neck junction, but successful fracture union. The average American Orthopedic Foot and Ankle Society ankle score was 88.8 overall, and 92.1 in fractures that united within 24 weeks. Distal tibial locking plates have high fracture union rates, minimum soft tissue complications, and good functional outcomes. The literature shows similar fracture union and complication rates in locking and nonlocking plates. Copyright © 2012 by Lippincott Williams & Wilkins

  18. [Effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation].

    PubMed

    Ge, Qihang; Wan, Chunyou; Liu, Yabei; Ji, Xu; Ma, Jihai; Cao, Haikun; Yong, Wei; Liu, Zhao; Zhang, Ningning

    2017-08-01

    To investigate the effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation. The data of 45 cases with tibial and fibular open fractures treated by Taylor space stent fixation who meet the selection criteria between January 2015 and June 2016 were retrospectively analysed. The patients were divided into trial group (23 cases) and control group (22 cases) according to whether the axial stress stimulation was performed after operation. There was no significant difference in gender, age, affected side, cause of injury, type of fracture, and interval time from injury to operation between 2 groups ( P >0.05). The axial stress stimulation was performed in trial group after operation. The axial load sharing ratio was tested, and when the value was less than 10%, the external fixator was removed. The fracture healing time, full weight-bearing time, and external fixator removal time were recorded and compared. After 6 months of external fixator removal, the function of the limb was assessed by Johner-Wruhs criteria for evaluation of final effectiveness of treatment of tibial shaft fractures. There were 2 and 3 cases of needle foreign body reaction in trial group and control group, respectively, and healed after symptomatic anti allergic treatment. All the patients were followed up 8-12 months with an average of 10 months. All the fractures reached clinical healing, no complication such as delayed union, nonunion, or osteomyelitis occurred. The fracture healing time, full weight-bearing time, and external fixator removal time in trial group were significantly shorter than those in control group ( P <0.05). After 6 months of external fixator removal, the function of the limb was excellent in 13 cases, good in 6 cases, fair in 3 cases, and poor in 1 case in trial group, with an excellent and good rate of 82.6%; and was excellent in 5 cases, good in 10 cases, fair in 4 cases, and poor in 3 cases in control group, with an

  19. Immediate versus delayed intramedullary nailing for open fractures of the tibial shaft: a multivariate analysis of factors affecting deep infection and fracture healing.

    PubMed

    Yokoyama, Kazuhiko; Itoman, Moritoshi; Uchino, Masataka; Fukushima, Kensuke; Nitta, Hiroshi; Kojima, Yoshiaki

    2008-10-01

    The purpose of this study was to evaluate contributing factors affecting deep infection and fracture healing of open tibia fractures treated with locked intramedullary nailing (IMN) by multivariate analysis. We examined 99 open tibial fractures (98 patients) treated with immediate or delayed locked IMN in static fashion from 1991 to 2002. Multivariate analyses following univariate analyses were derived to determine predictors of deep infection, nonunion, and healing time to union. The following predictive variables of deep infection were selected for analysis: age, sex, Gustilo type, fracture grade by AO type, fracture location, timing or method of IMN, reamed or unreamed nailing, debridement time (< or =6 h or >6 h), method of soft-tissue management, skin closure time (< or =1 week or >1 week), existence of polytrauma (ISS< 18 or ISS> or =18), existence of floating knee injury, and existence of superficial/pin site infection. The predictive variables of nonunion selected for analysis was the same as those for deep infection, with the addition of deep infection for exchange of pin site infection. The predictive variables of union time selected for analysis was the same as those for nonunion, excluding of location, debridement time, and existence of floating knee and superficial infection. Six (6.1%; type II Gustilo n=1, type IIIB Gustilo n=5) of the 99 open tibial fractures developed deep infections. Multivariate analysis revealed that timing or method of IMN, debridement time, method of soft-tissue management, and existence of superficial or pin site infection significantly correlated with the occurrence of deep infection (P< 0.0001). In the immediate nailing group alone, the deep infection rate in type IIIB + IIIC was significantly higher than those in type I + II and IIIA (P = 0.016). Nonunion occurred in 17 fractures (20.3%, 17/84). Multivariate analysis revealed that Gustilo type, skin closure time, and existence of deep infection significantly correlated with

  20. Effectiveness of various isometric exercises at improving bone strength in cortical regions prone to distal tibial stress fractures.

    PubMed

    Florio, C S

    2018-06-01

    A computational model was used to compare the local bone strengthening effectiveness of various isometric exercises that may reduce the likelihood of distal tibial stress fractures. The developed model predicts local endosteal and periosteal cortical accretion and resorption based on relative local and global measures of the tibial stress state and its surface variation. Using a multisegment 3-dimensional leg model, tibia shape adaptations due to 33 combinations of hip, knee, and ankle joint angles and the direction of a single or sequential series of generated isometric resultant forces were predicted. The maximum stress at a common fracture-prone region in each optimized geometry was compared under likely stress fracture-inducing midstance jogging conditions. No direct correlations were found between stress reductions over an initially uniform circular hollow cylindrical geometry under these critical design conditions and the exercise-based sets of active muscles, joint angles, or individual muscle force and local stress magnitudes. Additionally, typically favorable increases in cross-sectional geometric measures did not guarantee stress decreases at these locations. Instead, tibial stress distributions under the exercise conditions best predicted strengthening ability. Exercises producing larger anterior distal stresses created optimized tibia shapes that better resisted the high midstance jogging bending stresses. Bent leg configurations generating anteriorly directed or inferiorly directed resultant forces created favorable adaptations. None of the studied loads produced by a straight leg was significantly advantageous. These predictions and the insight gained can provide preliminary guidance in the screening and development of targeted bone strengthening techniques for those susceptible to distal tibial stress fractures. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Temporary Stabilization with External Fixator in ‘Tripolar’ Configuration in Two Steps Treatment of Tibial Pilon Fractures

    PubMed Central

    Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè

    2016-01-01

    Background: The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. Methods: We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. Results: We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation Conclusion: Temporary stabilization with external fixator in ‘tripolar’ configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases. PMID:27123151

  2. Laser/LED phototherapy on the repair of tibial fracture treated with wire osteosynthesis evaluated by Raman spectroscopy.

    PubMed

    Pinheiro, Antônio L B; Soares, Luiz G P; da Silva, Aline C P; Santos, Nicole R S; da Silva, Anna Paula L T; Neves, Bruno Luiz R C; Soares, Amanda P; Silveira, Landulfo

    2018-04-23

    The aim of the present study was to assess, by means of Raman spectroscopy, the repair of complete surgical tibial fractures fixed with wire osteosynthesis (WO) treated or not with infrared laser (λ780 nm) or infrared light emitting diode (LED) (λ850 ± 10 nm) lights, 142.8 J/cm 2 per treatment, associated or not to the use of mineral trioxide aggregate (MTA) cement. Surgical tibial fractures were created on 18 rabbits, and all fractures were fixed with WO and some groups were grafted with MTA. Irradiated groups received lights at every other day during 15 days, and all animals were sacrificed after 30 days, being the tibia removed. The results showed that only irradiation with either laser or LED influenced the peaks of phosphate hydroxyapatite (~ 960 cm -1 ). Collagen (~ 1450 cm -1 ) and carbonated hydroxyapatite (~ 1070 cm -1 ) peaks were influenced by both the use of MTA and the irradiation with either laser or LED. It is concluded that the use of either laser or LED phototherapy associated to MTA cement was efficacious on improving the repair of complete tibial fractures treated with wire osteosynthesis by increasing the synthesis of collagen matrix and creating a scaffold of calcium carbonate (carbonated hydroxyapatite-like) and the subsequent deposition of phosphate hydroxyapatite.

  3. [Application of rafting K-wire technique for tibial plateau fractures].

    PubMed

    Zhang, Xing-zhou; Yu, Wei-zhong; Li, Yun-feng; Liu, Yan-hui

    2015-12-01

    To summarize application of rafting K-wires technique for tibial plateau fractures. From January 2013 to January 2015,45 patients with tibial plateau fractures were treated by locking plate with rafting K-wires, including 33 males and 12 females with an average of 44.2 years old ranging from 22 to 56 years old. According to Schatzker classification, 6 cases were type II, 8 were type Ill, 4 were type IV, 4 were type V, and 5 were type VI. Allogeneic bone graft were performed for bone defects. All patients were fixed with two to five K-wires. Part of weight loading were encouraged at 3 months after operation,and full weight-loading were done at 5 months after operation. Postoperative complications were observed,and Rasmussen clinical and radiological assessment were used to evaluate clinical results. All Patients were followed up from 10 to 23 months with average of 14 months. According to Rasmussen clinical and radiological assessment, clinical scores 23.58 ± 6.33, radiological scores were 14.00 ± 6.33; and excellent and good rates were 82.2% and 77.8% respectively. Four patients occurred severe osteoporosis and collapse of articular surface; 5 patients occurred traumatic arthritis. Rafting K-wires technique with anatomized armor plate could effective fix and support platform collapse and joint bone fragments, increase support surface area and reduce postoperative reduction loss rate.

  4. Minimizing the complications of intramedullary nailing for distal third tibial shaft and metaphyseal fractures

    PubMed Central

    Yaligod, Vishwanath; Rudrappa, Girish H.; Nagendra, Srinivas; Shivanna, Umesh M.

    2013-01-01

    Background The complications of intramedullary nailing of distal third tibial shaft and metaphyseal fractures have a direct impact on ankle and hind foot function. Methods We retrospectively evaluated 28 patients. Unreamed nail was negotiated across the well reduced fracture till subchondral bone and fixed with 2 to 3 distal locking screws in different planes. Results Fracture union rate was 85%. Three out of 28 patients had malalignment. Mean ankle, hindfoot functional score was 85. Conclusion Complications can be minimized by impacting the unreamed nail till the subchondral bone while maintaining the fracture well reduced and by using multiple distal locking screws in different planes. PMID:24719527

  5. Which Surgical Treatment for Open Tibial Shaft Fractures Results in the Fewest Reoperations? A Network Meta-analysis.

    PubMed

    Foote, Clary J; Guyatt, Gordon H; Vignesh, K Nithin; Mundi, Raman; Chaudhry, Harman; Heels-Ansdell, Diane; Thabane, Lehana; Tornetta, Paul; Bhandari, Mohit

    2015-07-01

    Open tibial shaft fractures are one of the most devastating orthopaedic injuries. Surgical treatment options include reamed or unreamed nailing, plating, Ender nails, Ilizarov fixation, and external fixation. Using a network meta-analysis allows comparison and facilitates pooling of a diverse population of randomized trials across these approaches in ways that a traditional meta-analysis does not. Our aim was to perform a network meta-analysis using evidence from randomized trials on the relative effect of alternative approaches on the risk of unplanned reoperation after open fractures of the tibial diaphysis. Our secondary study endpoints included malunion, deep infection, and superficial infection. A network meta-analysis allows for simultaneous consideration of the relative effectiveness of multiple treatment alternatives. To do this on the subject of surgical treatments for open tibial fractures, we began with systematic searches of databases (including EMBASE and MEDLINE) and performed hand searches of orthopaedic journals, bibliographies, abstracts from orthopaedic conferences, and orthopaedic textbooks, for all relevant material published between 1980 and 2013. Two authors independently screened abstracts and manuscripts and extracted the data, three evaluated the risk of bias in individual studies, and two applied Grading of Recommendation Assessment, Development and Evaluation (GRADE) criteria to bodies of evidence. We included all randomized and quasirandomized trials comparing two (or more) surgical treatment options for open tibial shaft fractures in predominantly (ie, > 80%) adult patients. We calculated pooled estimates for all direct comparisons and conducted a network meta-analysis combining direct and indirect evidence for all 15 comparisons between six stabilization strategies. Fourteen trials published between 1989 and November 2011 met our inclusion criteria; the trials comprised a total of 1279 patients surgically treated for open tibial

  6. "Shin splint" syndrome and tibial stress fracture in the same patient diagnosed by means of (99m)Tc-HMDP SPECT/CT.

    PubMed

    Vicente, Justo Serrano; Grande, Maria Luz Domínguez; Torre, Jose Rafael Infante; Madrid, Juan Ignacio Rayo; Barquero, Carmen Durán; Bernardo, Lucía García; Sánchez, Román Sánchez

    2013-04-01

    We show a patient who presented leg pain triggered by intense exercise. The most likely diagnosis was a possible tibial stress fracture or a "shin splint" syndrome (soleus enthesopathy). We performed a bone scintigraphy including SPECT/CT that revealed the presence of the two concomitant pathologies. SPECT/CT identified the hot spot superimposed with bone lesion in the tibial stress fracture and only remodeling activity without evidence of cortical lesions in the enthesopathy processes.

  7. Fibular fixation as an adjuvant to tibial intramedullary nailing in the treatment of combined distal third tibia and fibula fractures: a biomechanical investigation.

    PubMed

    Morin, Paul M; Reindl, Rudolf; Harvey, Edward J; Beckman, Lorne; Steffen, Thomas

    2008-02-01

    Distal third tibia fractures have classically been treated with standard plating, but intramedullary (IM) nailing has gained popularity. Owing to the lack of interference fit of the nail in the metaphyseal bone of the distal tibia, it may be beneficial to add rigid plating of the fibula to augment the overall stability of fracture fixation in this area. This study sought to assess the biomechanical effect of adding a fibular plate to standard IM nailing in the treatment of distal third tibia and fibula fractures. Eight cadaveric tibia specimens were used. Tibial fixation consisted of a solid titanium nail locked with 3 screws distally and 2 proximally, and fibular fixation consisted of a 3.5 mm low-contact dynamic compression plate. A section of tibia and fibula was removed. Testing was accomplished with an MTS machine. Each leg was tested 3 times; with and without a fibular plate and with a repetition of the initial test condition. Vertical displacements were tested with an axial load up to 500 N, and angular rotation was tested with torques up to 5 N*m. The difference in axial rotation was the only statistically significant finding (p = 0.003), with fibular fixation resulting in 1.1 degrees less rotation through the osteotomy site (17.96 degrees v. 19.10 degrees ). Over 35% of this rotational displacement occurred at the nail-locking bolt interface with the application of small torsional forces. Fibular plating in addition to tibial IM fixation of distal third tibia and fibula fractures leads to slightly increased resistance to torsional forces. This small improvement may not be clinically relevant.

  8. [An improved reduction technique for depression fractures of lateral tibial plateau].

    PubMed

    Wang, Hongchuan; Lou, Hua; Liu, Kai; Jiang, Junwei

    2013-01-01

    To investigate the improved reduction technique for depression fractures of the lateral tibial plateau and its effectiveness. Between January 2008 and December 2010; 48 patients (48 knees) with depression fractures of the lateral tibial plateau (Schatzker II or III fractures) were treated. There were 32 males and 16 females with an average age of 45.8 years (range, 16-79 years). All fractures were fresh closed fractures, which were caused by traffic accident in 27 cases, by falling from height in 5 cases, by crushing in 8 cases, and by sustained falls in 8 cases. According to Schatzker classification, 29 cases were classified as type II and 19 cases as type III. The lateral cortex was cut off to expose the depression and compacted cancellous bone was elevated to reset the articular surface. After reduction, autologous iliac bone graft and locking plate internal fixation were used. Healing of incision by first intention was achieved in all patients, and no complication occurred. All patients were followed up 1.7 years on average (range, 1-3 years). At last follow-up, the knee extension was (-0.5 +/- 0.3) degrees, and the knee flexion was (136.9 +/- 8.8) degrees. X-ray films showed that the fracture healing time was 52 weeks and no breakage of internal fixation occurred. According to Rasmussen clinical score, the results were excellent in 35 cases, good in 10 cases, and fair in 3 cases. According to Rasmussen radiographical score, the results were excellent in 41 cases, good in 7 cases; there were 41 excellent scores and 7 good scores of articular reduction; all gained good recovery of coronal and sagittal alignment and condylar width. The articular surface collapse was (1.0 +/- 0.7) mm at immediate postoperatively and (1.2 +/- 0.7) mm at last follow-up, showing no significant difference (t = -1.42, P = 0.20), but significant differences were found when compared with that at preoperation [(12.2 +/- 8.0) mm, P < 0.05]. This improved technique can provide a

  9. Functional outcome of Schatzker type V and VI tibial plateau fractures treated with dual plates

    PubMed Central

    Prasad, G Thiruvengita; Kumar, T Suresh; Kumar, R Krishna; Murthy, Ganapathy K; Sundaram, Nandkumar

    2013-01-01

    Background: Dual plate fixation in comminuted bicondylar tibial plateau fractures remains controversial. Open reduction and internal fixation, specifically through compromised soft tissues, has historically been associated with major wound complications. Alternate methods of treatment have been described, each with its own merits and demerits. We performed a retrospective study to evaluate the functional outcome of lateral and medial plate fixation of Schatzker type V and VI fractures through an anterolateral approach, and a medial minimally invasive approach or a posteromedial approach. Materials and Methods: We treated 46 tibial plateau fractures Schatzker type V and VI with lateral and medial plates through an anterolateral approach and a medial minimal invasive approach over an 8 years period. Six patients were lost to followup. Radiographs in two planes were taken in all cases. Immediate postoperative radiographs were assessed for quality of reduction and fixation. The functional outcome was evaluated according to the Oxford Knee Score criteria on followup. Results: Forty patients (33 men and 7 women) who completed the followup were included in the study. There were 20 Schatzker type V fractures and 20 Schatzker type VI fractures. The mean duration of followup was 4 years (range 1-8 years). All patients had a satisfactory articular reduction defined as ≤2 mm step-off or gap as assessed on followup. All patients had a good coronal and sagittal plane alignment, and articular width as assessed on supine X-rays of the knee in the anteroposterior (AP) and lateral views. The functional outcome, as assessed by the Oxford Knee Score, was excellent in 30 patients and good in 10 patients. All patients returned to their pre-injury level of activity and employment. There were no instances of deep infection. Conclusions: Dual plate fixation of severe bicondylar tibial plateau fractures is an excellent treatment option as it provides rigid fixation and allows early knee

  10. Transverse Stress Fracture of the Proximal Patella: A Case Report.

    PubMed

    Atsumi, Satoru; Arai, Yuji; Kato, Ko; Nishimura, Akinobu; Nakazora, Shigeto; Nakagawa, Shuji; Ikoma, Kazuya; Fujiwara, Hiroyoshi; Sudo, Akihiro; Kubo, Toshikazu

    2016-02-01

    Among stress fractures associated with sports activities, patellar stress fracture is rare. Regarding patella stress fractures, so far only distal transverse or lateral longitudinal fractures have been reported, but there are no reports of transverse fractures occurring in the proximal patella. We describe an extremely rare case of transverse stress fracture of proximal patella in a 9-year-old athlete.A 9-year old boy, who participated in sports (sprints and Kendo) presented with left knee pain without any external injury. In plain radiographs, a fracture line was observed in the proximal 1/3 of the left patella, and a patella stress fracture was diagnosed. For treatment, because 7 months of conservative therapy showed no improvement, internal fixation was carried out using Acutrak screws, and bone union was thus achieved. Three months after the operation, he was able to return to his previous level of athletic sports activity.Regarding the mechanism of onset, it is believed that the causes are longitudinal traction force and patellofemoral contact pressure. On the other hand, the contact region of the patella with the femur changes with the flexion angle of the knee. In the current case, the fracture occurred at a site where the patella was in contact with the femur at a flexion angle of >90°, so it is believed that it occurred as a clinical condition from being subjected to repeated longitudinal traction force and patellofemoral contact pressure at a flexion angle of >90°, during the sports activities of sprints and Kendo. The nonunion of the transverse stress fracture of his proximal patella was successfully treated with internal fixation using Acutrak screws.

  11. Percutaneous or Open Reduction of Closed Tibial Shaft Fractures During Intramedullary Nailing Does Not Increase Wound Complications, Infection or Nonunion Rates.

    PubMed

    Auston, Darryl A; Meiss, Jordan; Serrano, Rafael; Sellers, Thomas; Carlson, Gregory; Hoggard, Timothy; Beebe, Michael; Quade, Jonathan; Watson, David; Simpson, Robert Bruce; Kistler, Brian; Shah, Anjan; Sanders, Roy; Mir, Hassan R

    2017-04-01

    To compare the incidence of complications (wound, infection, and nonunion) among those patients treated with closed, percutaneous, and open intramedullary nailing for closed tibial shaft fractures. Retrospective review. Multiple trauma centers. Skeletally mature patients with closed tibia fractures amenable to treatment with an intramedullary device. Intramedullary fixation with closed, percutaneous, or open reduction. Superficial wound complication, deep infection, nonunion. A total of 317 tibial shaft fractures in 315 patients were included in the study. Two-hundred fractures in 198 patients were treated with closed reduction, 61 fractures in 61 patients were treated with percutaneous reduction, and 56 fractures in 56 patients were treated with formal open reduction. The superficial wound complication rate was 1% (2/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 3.6% (2/56) for the open group with no statistical difference between the groups (P = 0.179). The deep infection rate was 2% (4/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 7.1% (4/56) for the open group with no significant difference between the groups (P = 0.133). Nonunion rate was 5.0% (10/200) for the closed group, 4.9% (3/61) for the percutaneous group, and 7.1% (4/56) for the open group, with no statistical difference between the groups (P = 0.492). This is the largest reported series of closed tibial shaft fractures nailed with percutaneous and open reduction. Percutaneous or open reduction did not result in increased wound complications, infection, or nonunion rates. Carefully performed percutaneous or open approaches can be safely used in obtaining reduction of difficult tibial shaft fractures treated with intramedullary devices. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  12. [Comparison study on two operations for treatment of extra-articular distal tibial fracture].

    PubMed

    Qi, Haotian; Li, Weikang; Zhao, Yongjie; Zhang, Yinguang; Liu, Zhaojie; Jia, Jian

    2013-11-01

    To compare the effectiveness between minimally invasive plate osteosynthesis (MIPO) and open reduction and internal fixation (ORIF) for treatment of extra-articular distal tibial fracture. Between March 2009 and March 2012, 57 patients with extra-articular distal tibial fractures were treated, and the clinical data were retrospectively analyzed. Of 57 cases, 31 were treated with MIPO (MIPO group), and 26 with ORIF (ORIF group). There was no significant difference in gender, age, cause of injury, type of fractures, complication, and time from injury to operation between 2 groups (P > 0.05). The operation time, intraoperative blood loss, fracture healing time, and complications were compared between 2 groups. There was no significant difference in operation time and intraoperative blood loss between 2 groups (P > 0.05). Wound infection occurred in 5 cases [2 in MIPO group (6.5%) and 3 in ORIF group (11.5%)] showing no significant difference (Chi(2)=0.651, P=0.499). The other wound obtained healing by first intention. All cases were followed up 13-24 months (mean, 15 months). No significant difference was found in the average healing time between 2 groups and between patients with types A and B by AO classification (P > 0.05); in patients with type C, the healing time in MIPO group was significantly shorter than that in ORIF group (t= -2.277, P=0.033). Delayed union was observed in 3 cases of MIPO group (9.7%) and in 4 cases of ORIF group (15.4%), showing no significant difference (Chi(2)=0.428, P=0.691). Mal-union occurred in 4 cases of MIPO group (12.9%) and in 1 case of ORIF group (3.8%), showing no significant difference (Chi(2)=1.449, P=0.362). No significant difference was found in Mazur score between 2 groups (t=0.480, P=0.633). The excellent and good rate was 93.5% in MIPO group (excellent in 24 cases, good in 5 cases, fair in 1 case, and poor in 1 case) and was 92.3% in ORIF group (excellent in 18 cases, good in 6 cases, and poor in 2 cases), and the

  13. Fractography and oxidative analysis of gamma inert sterilized posterior-stabilized tibial insert post fractures: report of two cases.

    PubMed

    Ansari, Farzana; Chang, Jennifer; Huddleston, James; Van Citters, Douglas; Ries, Michael; Pruitt, Lisa

    2013-12-01

    Highly crosslinked ultra-high molecular weight polyethylene (UHMWPE) has shown success in reducing wear in hip arthroplasty but there remains skepticism about its use in Total Knee Replacement (TKR) inserts that are known to experience fatigue loading and higher local cyclic contact stresses. Two Legacy Posterior-Stabilized (LPS) Zimmer NexGen tibial implants sterilized by gamma irradiation in an inert environment with posts that fractured in vivo were analyzed. Failure mechanisms were determined using optical and scanning electron microscopy along with oxidative analysis via Fourier Transform Infra-Red (FTIR) spectroscopy. Micrographs of one retrieval revealed fatigue crack initiation on opposite sides of the post and quasi-brittle micromechanisms of crack propagation. FTIR of this retrieval revealed no oxidation. The fracture surface image of the second retrieval indicated a brittle fracture process and FTIR revealed oxidation in the explant. These two cases suggest that crosslinking of UHMWPE as a manufacturing process or sterilization method in conjunction with designs that incorporate high stress concentrations, such as the tibial post, may reduce material strength. Moreover, free radicals generated from ionizing radiation can render the polymer susceptible to oxidative embrittlement. Our findings suggest that tibial post fractures may be the results of in vivo oxidation and low level crosslinking. These and previous reports of fractured crosslinked UHMWPE devices implores caution when used with high stress concentrations, particularly when considering the potential for in vivo oxidation in TKR. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Early Tibiotalocalcaneal Arthrodesis Intramedullary Nail for Treatment of a Complex Tibial Pilon Fracture (AO/OTA 43-C).

    PubMed

    Hsu, Andrew R; Szatkowski, Jan P

    2015-06-01

    Management of severely comminuted, complete articular tibial pilon fractures (AO/OTA 43-C) remains a challenge, with few treatment options providing good clinical outcomes. Open reduction and internal fixation of the tibial plafond, tibiotalar arthrodesis, and salvage hindfoot reconstruction procedures are all associated with surgical complications and functional limitations. In this report, we present a case of a complex pilon fracture in a patient with multiple medical comorbidities and socioeconomic disadvantages that was successfully and acutely treated with a retrograde tibiotalocalcaneal hindfoot arthrodesis nail. At final follow-up examination, the patient had decreased pain, a stable plantigrade foot, and could ambulate with normal shoes without any assistive devices. Therapeutic, Level IV: Case series. © 2014 The Author(s).

  15. Biomechanical Strength of Retrograde Fixation in Proximal Third Scaphoid Fractures.

    PubMed

    Daly, Charles A; Boden, Allison L; Hutton, William C; Gottschalk, Michael B

    2018-04-01

    Current techniques for fixation of proximal pole scaphoid fractures utilize antegrade fixation via a dorsal approach endangering the delicate vascular supply of the dorsal scaphoid. Volar and dorsal approaches demonstrate equivalent clinical outcomes in scaphoid wrist fractures, but no study has evaluated the biomechanical strength for fractures of the proximal pole. This study compares biomechanical strength of antegrade and retrograde fixation for fractures of the proximal pole of the scaphoid. A simulated proximal pole scaphoid fracture was produced in 22 matched cadaveric scaphoids, which were then assigned randomly to either antegrade or retrograde fixation with a cannulated headless compression screw. Cyclic loading and load to failure testing were performed and screw length, number of cycles, and maximum load sustained were recorded. There were no significant differences in average screw length (25.5 mm vs 25.6 mm, P = .934), average number of cyclic loading cycles (3738 vs 3847, P = .552), average load to failure (348 N vs 371 N, P = .357), and number of catastrophic failures observed between the antegrade and retrograde fixation groups (3 in each). Practical equivalence between the 2 groups was calculated and the 2 groups were demonstrated to be practically equivalent (upper threshold P = .010). For this model of proximal pole scaphoid wrist fractures, antegrade and retrograde screw configuration have been proven to be equivalent in terms of biomechanical strength. With further clinical study, we hope surgeons will be able to make their decision for fixation technique based on approaches to bone grafting, concern for tenuous blood supply, and surgeon preference without fear of poor biomechanical properties.

  16. [Clinical application of blocking screws and rooting technique in the treatment of distal tibial fracture with interlocking intramedullary nail].

    PubMed

    Zhu, Hai-Bing; Wu, Li-Guo; Fang, Zhi-Song; Luo, Cong-Feng; Wang, Qing-Feng; Ma, Yi-Ping; Gao, Hong; Fu, Guo-Hai; Hu, Cheng-Ting

    2012-07-01

    To introduce the clinical method of blocking screws and rooting technique in the treatment of distal tibial fracture with interlocking intramedullary nails. From June 2006 to March 2011, 26 patients with distal tibial fracture were treated with interlocking intramedullary nails using blocking screws and rooting technique, included 18 males and 8 females with an average age of 46.2 years old ranging from 24 to 64 years. According to AO classification: 10 cases of type A1, 4 cases of type A2, 8 cases of type B1, 4 cases of type B2. The average distance of the fractures end to the ankle joint was 85 mm ranging from 55 to 125 mm, the mean time between injured and operation was 4.5 days. The patients were evaluated with pain, range of motion, walking. All cases were followed-up for 6 to 22 months (averaged 15 months). According to Iowa ankle joint grading system,the score was improved from preoperative (66.8 +/- 8.2) to postoperative (94.6 +/- 4.8). All fractures had united, and got satisfactory reduction and stable fixation with no complications had happen such as breakage of screw. Fixation with interlocking intramedullary nail using blocking screws and rooting technique in treating distal tibial fracture, is a safe and effective technique for the improvement of stability.

  17. Incidence and risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture: A systematic review and meta-analysis.

    PubMed

    Shao, Jiashen; Chang, Hengrui; Zhu, Yanbin; Chen, Wei; Zheng, Zhanle; Zhang, Huixin; Zhang, Yingze

    2017-05-01

    This study aimed to quantitatively summarize the risk factors associated with surgical site infection after open reduction and internal fixation of tibial plateau fracture. Medline, Embase, CNKI, Wanfang database and Cochrane central database were searched for relevant original studies from database inception to October 2016. Eligible studies had to meet quality assessment criteria according to the Newcastle-Ottawa Scale, and had to evaluate the risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture. Stata 11.0 software was used for this meta-analysis. Eight studies involving 2214 cases of tibial plateau fracture treated by open reduction and internal fixation and 219 cases of surgical site infection were included in this meta-analysis. The following parameters were identified as significant risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture (p < 0.05): open fracture (OR 3.78; 95% CI 2.71-5.27), compartment syndrome (OR 3.53; 95% CI 2.13-5.86), operative time (OR 2.15; 95% CI 1.53-3.02), tobacco use (OR 2.13; 95% CI 1.13-3.99), and external fixation (OR 2.07; 95% CI 1.05-4.09). Other factors, including male sex, were not identified as risk factors for surgical site infection. Patients with the abovementioned medical conditions are at risk of surgical site infection after open reduction and internal fixation of tibial plateau fracture. Surgeons should be cognizant of these risks and give relevant preoperative advice. Copyright © 2017. Published by Elsevier Ltd.

  18. A scoping review of biomechanical testing for proximal humerus fracture implants.

    PubMed

    Cruickshank, David; Lefaivre, Kelly A; Johal, Herman; MacIntyre, Norma J; Sprague, Sheila A; Scott, Taryn; Guy, Pierre; Cripton, Peter A; McKee, Michael; Bhandari, Mohit; Slobogean, Gerard P

    2015-07-30

    Fixation failure is a relatively common sequela of surgical management of proximal humerus fractures (PHF). The purpose of this study is to understand the current state of the literature with regard to the biomechanical testing of proximal humerus fracture implants. A scoping review of the proximal humerus fracture literature was performed, and studies testing the mechanical properties of a PHF treatment were included in this review. Descriptive statistics were used to summarize the characteristics and methods of the included studies. 1,051 proximal humerus fracture studies were reviewed; 67 studies met our inclusion criteria. The most common specimen used was cadaver bone (87%), followed by sawbones (7%) and animal bones (4%). A two-part fracture pattern was tested most frequently (68%), followed by three-part (23%), and four-part (8%). Implants tested included locking plates (52%), intramedullary devices (25%), and non-locking plates (25%). Hemi-arthroplasty was tested in 5 studies (7%), with no studies using reverse total shoulder arthroplasty (RTSA) implants. Torque was the most common mode of force applied (51%), followed by axial loading (45%), and cantilever bending (34%). Substantial testing diversity was observed across all studies. The biomechanical literature was found to be both diverse and heterogeneous. More complex fracture patterns and RTSA implants have not been adequately tested. These gaps in the current literature will need to be addressed to ensure that future biomechanical research is clinically relevant and capable of improving the outcomes of challenging proximal humerus fracture patterns.

  19. Comparison of suprapatellar and infrapatellar intramedullary nailing for tibial shaft fractures: a systematic review and meta-analysis.

    PubMed

    Yang, Liqing; Sun, Yuefeng; Li, Ge

    2018-06-14

    Optimal surgical approach for tibial shaft fractures remains controversial. We perform a meta-analysis from randomized controlled trials (RCTs) to compare the clinical efficacy and prognosis between infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. PubMed, OVID, Embase, ScienceDirect, and Web of Science were searched up to December 2017 for comparative RCTs involving infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. Primary outcomes were blood loss, visual analog scale (VAS) score, range of motion, Lysholm knee scores, and fluoroscopy times. Secondary outcomes were length of hospital stay and postoperative complications. We assessed statistical heterogeneity for each outcome with the use of a standard χ 2 test and the I 2 statistic. The meta-analysis was undertaken using Stata 14.0. Four RCTs involving 293 participants were included in our study. The present meta-analysis indicated that there were significant differences between infrapatellar and suprapatellar intramedullary nail regarding the total blood loss, VAS scores, Lysholm knee scores, and fluoroscopy times. Suprapatellar intramedullary nailing could significantly reduce total blood loss, postoperative knee pain, and fluoroscopy times compared to infrapatellar approach. Additionally, it was associated with an improved Lysholm knee scores. High-quality RCTs were still required for further investigation.

  20. Return to sports after stress fractures of the tibial diaphysis: a systematic review.

    PubMed

    Robertson, G A J; Wood, A M

    2015-06-01

    This review aims to provide information on the time taken to resume sport following tibial diaphyseal stress fractures (TDSFs). A systematic search of Medline, EMBASE, CINHAL, Cochrane, Web of Science, PEDro, Sports Discus, Scopus and Google Scholar was performed using the keywords 'tibial', 'tibia', 'stress', 'fractures', 'athletes', 'sports', 'non-operative', 'conservative', 'operative' and 'return to sport'. Twenty-seven studies were included: 16 reported specifically on anterior TDSFs and 5 on posterior TDSFs. The general principles were to primarily attempt non-operative management for all TDSFs and to consider operative intervention for anterior TDSFs that remained symptomatic after 3-6 months. Anterior TDSFs showed a prolonged return to sport. The best time to return to sport and the optimal management modalities for TDSFs remain undefined. Management of TDSFs should include a full assessment of training methods, equipment and diet to modify pre-disposing factors. Future prospective studies should aim to establish the optimal treatment modalities for TDSFs. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Calcium phosphate cement augmentation in the treatment of depressed tibial plateau fractures with open reduction and internal fixation.

    PubMed

    Oztürkmen, Yusuf; Caniklioğlu, Mustafa; Karamehmetoğlu, Mahmut; Sükür, Erhan

    2010-01-01

    We aimed to evaluate the clinical and radiological outcomes of open reduction and internal fixation augmented with calcium phosphate cement (CPC) in the treatment of depressed tibial plateau fractures. Twenty-eight knees of 28 patients [19 males and 9 females; mean age, 41.2 years (range 22-72 years)] who had open reduction and internal fixation combined with CPC augmentation were included in this study. Seventeen fractures were Schatzker type II, 5 were type III, 3 were type IV, 2 were type V, and 1 was type VI. CPC was used to fill the subchondral bone defects in all knees. Fixation of the fragments was done with screws in 3 knees (10%). Standard proximal tibial plates or buttress plates were used in 25 knees (90%) with an additional split fragment extending distally to achieve internal fixation. Full weight-bearing was allowed in 6.4 weeks (range 6-12 weeks) after surgery. Resorption of CPC granules was defined as the decrease in the size and density of grafting material on radiographs. Rasmussen's radiological and clinical scores were determined postoperatively. Functionality was assessed with Lysholm knee scoring system. Activity was graded with Tegner's activity scale. Union was achieved in all patients with a mean follow-up of 22.2 months (range 6-36 months). There were no intraoperative complications. At the latest follow-up radiographs, resorption of the graft was observed in 25 knees (89%). Rasmussen's radiologic score was excellent in 17 patients (61%), good in 9 patients (32%), and fair in 2 patients (7%). Rasmussen's clinical score was excellent in 9 patients (32%), good in 18 patients (64%), and fair in 1 patient (4%). According to the Lysholm knee score, functional results were excellent in 16 patients (57%), good in 8 patients (29%), and fair in 4 patients (14%). Twenty-two patients (78%) achieved the preoperative activity level after surgery, and there was no significant difference between the mean preoperative and postoperative Tegner scores (4

  2. Surgical treatment of extra-articular or simple intra-articular distal tibial fractures: MIPO versus supercutaneous plating.

    PubMed

    He, Xianfeng; Zhang, Jingwei; Li, Ming; Yu, Yihui; Zhu, Limei

    2014-10-01

    Minimally invasive plate osteosynthesis (MIPO) has become a widely accepted technique to treat distal tibial fractures. Recently, the novel application of a locking plate used as an external fixator (supercutaneous plating) was introduced for the management of open fractures and infected nonunions and even as an adjunct in distraction osteogenesis, which is considered another less invasive method. The aim of this study was to compare the results of supercutaneous plating with closed reduction and minimally invasive plating in the treatment of distal tibial fractures. Forty-eight matched patients were divided according to age, sex, Injury Severity Score, and fracture pattern into the MIPO group and the supercutaneous plating group. Minimum follow-up was 12 months (mean, 18.5 months; range, 12-26 months). No patient had nonunion, hardware breakdown, or deep infection. Patients in the supercutaneous plating group had a significantly shorter mean operative time (65.6±13.2 vs 85.9±14.0 minutes; P=.000), hospital stay (7.5±2.0 vs 13.0±4.4 days; P=.000), and union time (15.2±2.4 vs 17.0±2.8 weeks; P=.000). In the MIPO group, 15 (62.5%) patients reported implant impingement or discomfort and there was 1 incidence of stripping of 15.6% at the time of locking screw removal, whereas in the supercutaneous plating group, no patient reported skin irritation, and removal of the supercutaneous plate was easily performed in clinic without anesthesia. Distal tibial fractures may be treated successfully with MIPO or supercutaneous plating. However, the supercutaneous plating technique may represent a superior surgical option because it offers advantages in terms of mean operative time, hospital stay, and union time; skin irritation; and implant removal. Copyright 2014, SLACK Incorporated.

  3. External fixation combined with delayed internal fixation in treatment of tibial plateau fractures with dislocation

    PubMed Central

    Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao

    2017-01-01

    Abstract The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation. Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups. The mean follow-up time was 18.6 months (range: 5–24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5–9 months) and 6.0 months (range: 5–8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°–150°) and 135° (range: 100°–160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05). External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation. PMID:29019890

  4. Proximal tibial strain in medial unicompartmental knee replacements: A biomechanical study of implant design.

    PubMed

    Scott, C E H; Eaton, M J; Nutton, R W; Wade, F A; Pankaj, P; Evans, S L

    2013-10-01

    As many as 25% to 40% of unicompartmental knee replacement (UKR) revisions are performed for pain, a possible cause of which is proximal tibial strain. The aim of this study was to examine the effect of UKR implant design and material on cortical and cancellous proximal tibial strain in a synthetic bone model. Composite Sawbone tibiae were implanted with cemented UKR components of different designs, either all-polyethylene or metal-backed. The tibiae were subsequently loaded in 500 N increments to 2500 N, unloading between increments. Cortical surface strain was measured using a digital image correlation technique. Cancellous damage was measured using acoustic emission, an engineering technique that detects sonic waves ('hits') produced when damage occurs in material. Anteromedial cortical surface strain showed significant differences between implants at 1500 N and 2500 N in the proximal 10 mm only (p < 0.001), with relative strain shielding in metal-backed implants. Acoustic emission showed significant differences in cancellous bone damage between implants at all loads (p = 0.001). All-polyethylene implants displayed 16.6 times the total number of cumulative acoustic emission hits as controls. All-polyethylene implants also displayed more hits than controls at all loads (p < 0.001), more than metal-backed implants at loads ≥ 1500 N (p < 0.001), and greater acoustic emission activity on unloading than controls (p = 0.01), reflecting a lack of implant stiffness. All-polyethylene implants were associated with a significant increase in damage at the microscopic level compared with metal-backed implants, even at low loads. All-polyethylene implants should be used with caution in patients who are likely to impose large loads across their knee joint.

  5. Tibial avulsion fracture of the posterior root of the medial meniscus in children.

    PubMed

    Iversen, Jonas Vestergård; Krogsgaard, Michael Rindom

    2014-01-01

    Few reports have described avulsion fractures of the posterior root of the medial meniscus in skeletally immature patients. This lesion should not be overlooked as it damages the load absorptive (distributive) function of the meniscus, increasing the risk of cartilage degeneration. Two cases of displaced avulsion fractures of the posterior root of the medial meniscus in children are presented along with a concise report of the literature regarding avulsion fractures of the posterior root of the medial meniscus. Both avulsions were reattached arthroscopically by trans-tibial pull-out sutures with a good clinical result at 2-years follow-up, and in one case, the avulsion was found at re-arthroscopy after 6 weeks to have healed.

  6. Treatment of open tibial shaft fracture with soft tissue and bone defect caused by aircraft bomb--case report.

    PubMed

    Golubović, Zoran; Vidić, Goran; Trenkić, Srbobran; Vukasinović, Zoran; Lesić, Aleksandar; Stojiljković, Predrag; Stevanović, Goran; Golubović, Ivan; Visnjić, Aleksandar; Najman, Stevo

    2010-01-01

    Aircraft bombs can cause severe orthopaedic injuries. Tibia shaft fractures caused by aircraft bombs are mostly comminuted and followed by bone defects, which makes the healing process extremely difficult and prone to numerous complications. The goal of this paper is to present the method of treatment and the end results of treatment of a serious open tibial fracture with soft and bone tissue defects resulting from aircraft bomb shrapnel wounds. A 26-year-old patient presented with a tibial fracture as the result of a cluster bomb shrapnel wound. He was treated applying the method of external bone fixation done two days after wounding, as well as of early coverage of the lower leg soft tissue defects done on the tenth day after the external fixation of the fracture. The external fixator was removed after five months, whereas the treatment was continued by means of functional plaster cast for another two months. The final functional result was good. Radical wound debridement, external bone fixation of the fracture, and early reconstruction of any soft tissue and bone defects are the main elements of the treatment of serious fractures.

  7. Arthroscopy-assisted reduction of posteromedial tibial plateau fractures with buttress plate and cannulated screw construct.

    PubMed

    Chiu, Chih-Hao; Cheng, Chun-Ying; Tsai, Min-Chain; Chang, Shih-Sheng; Chen, Alvin Chao-Yu; Chen, Yeung-Jen; Chan, Yi-Sheng

    2013-08-01

    To present the radiologic and clinical results of posteromedial fractures treated with arthroscopy-assisted reduction and buttress plate and cannulated screw fixation. Twenty-five patients with posteromedial tibial plateau fractures treated by the described technique were included in this study. According to the Schatzker classification, there were 5 type IV fractures (20%), 2 type V fractures (8%), and 18 type VI fractures (72%). The mean age at operation was 46 years (range, 21 to 79 years). The mean follow-up period was 86 months (range, 60 to 108 months). Clinical and radiologic outcomes were scored by the Rasmussen system. Subjective data were collected to assess swelling, difficulty climbing stairs, joint stability, ability to work and participate in sports, and overall patient satisfaction with recovery. Secondary osteoarthritis was diagnosed when radiographs showed a narrowed joint space in the injured knee at follow-up in comparison with the films taken at the time of injury. The mean postoperative Rasmussen clinical score was 25.9 (range, 18 to 29), and the mean radiologic score was 15.8 (range, 10 to 18). All 25 fractures achieved successful union, and 92% had good or excellent clinical and radiologic results. The 3 fracture types did not significantly differ in Rasmussen scores or rates of satisfactory results (P > .05). Secondary osteoarthritis was noted in 6 injured knees (24%). Arthroscopy-assisted reduction with buttress plate and cannulated screw fixation can restore posteromedial tibial plateau fractures of the knee with well-documented radiographic healing, good clinical outcomes, and low complication rates. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. [ARTHROSCOPIC TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE IN ADOLESCENTS WITH EPIPHYSEAL UNCLOSURE].

    PubMed

    Liu, Yang; Sun, Xuebin; Zhang, Keyuan; Li, Gang; Ni, Jiati

    2015-06-01

    To evaluate the clinical results of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fractures in adolescents with epiphyseal unclosure. Between January 2011 and October 2013, 35 knees with ACL tibial eminence avulsion fractures (35 patients with epiphyseal unclosure) were arthroscopically treated with suture fixation. There were 25 males and 10 females, aged 8-16 years (mean, 14.7 years). The causes included sports injury in 24 cases, traffic accident injury in 9 cases, and daily life injury in 2 cases. According to Meyers-McKeever classification criteria, there were 27 cases of type II and 8 cases of type III. Five cases had meniscus injury. The preoperative the International Knee Documentation Committee (IKDC) score was 48.7 ± 3.2, and Lysholm score was 51.2 ± 4.5. The time from injury to operation was 2-16 days (mean, 5 days). Primary healing of incision was obtained in all patients. The mean follow-up time was 22.4 months (range, 12-32 months). Anatomical reduction was achieved in 28 cases and satisfactory reduction in 7 cases. X-ray films showed all fractures healing at last follow-up. There was no limb shortening deformity, varus knee, or valgus knee. Lachman test results were all negative. The other knees had normal range of motion except 1 knee with limited flexion, whose range of motion returned to 0-120° after treatment. At last follow-up, the IKDC score was significantly improved to 93.2 ± 4.1 (t = -53.442, P = 0.000), and the Lysholm score was significantly increased to 96.2 ± 2.5 (t = -56.242, P = 0.000). The arthroscopic fixation technique has satisfactory results for the reduction and fixation of ACL tibial eminence avulsion fracture in the adolescents with epiphyseal unclosure because of little trauma and quick recovery.

  9. Proximal Humerus Fractures: Evaluation and Management in the Elderly Patient

    PubMed Central

    Grawe, Brian

    2018-01-01

    Introduction: Proximal humerus fractures are common in the elderly. The evaluation and management of these injuries is often controversial. The purpose of this study is to review recent evidence and provide updated recommendations for treating proximal humerus fractures in the elderly. Methods: A literature review of peer-reviewed publications related to the evaluation and management of proximal humerus fractures in the elderly was performed. There was a focus on randomized controlled trials and systematic reviews published within the last 5 years. Results: The incidence of proximal humerus fractures is increasing. It is a common osteoporotic fracture. Bone density is a predictor of reduction quality and can be readily assessed with anteroposterior views of the shoulder. Social independence is a predictor of outcome, whereas age is not. Many fractures are minimally displaced and respond acceptably to nonoperative management. Displaced and severe fractures are most frequently treated operatively with intramedullary nails, locking plates, percutaneous techniques, or arthroplasty. Discussion: Evidence from randomized controlled trials and systematic reviews is insufficient to recommend a treatment; however, most techniques have acceptable or good outcomes. Evaluation should include an assessment of the patient’s bone quality, social independence, and surgical risk factors. With internal fixation, special attention should be paid to medial comminution, varus angulation, and restoration of the calcar. With arthroplasty, attention should be paid to anatomic restoration of the tuberosities and proper placement of the prosthesis. Conclusion: A majority of minimally displaced fractures can be treated conservatively with early physical therapy. Treatment for displaced fractures should consider the patient’s level of independence, bone quality, and surgical risk factors. Fixation with percutaneous techniques, intramedullary nails, locking plates, and arthroplasty are all

  10. Spontaneous patella fracture associated with anterior tibial tubercle pseudarthrosis in a revised knee replacement following knee Arthrodesis

    PubMed Central

    2013-01-01

    Background Conversion of a knee arthrodesis to a Total Knee Arthroplasty is an uncommon procedure. Revision Total Knee Arthroplasty in this setting presents the surgeon with a number of challenges including the management of the extensor mechanism and patella. Case presentation We describe a unique case of a 69 years old Caucasian man who underwent a revision Total Knee Arthroplasty using a tibial tubercle osteotomy after a previous conversion of a knee arthrodesis without patella resurfacing. Unfortunately 9 months following surgery a tibial tubercle pseudarthrosis and spontaneous patella fracture occurred. Both were managed with open reduction and internal fixation. At 30 months follow-up the tibial tubercle osteotomy had completely consolidated while the patella fracture was still evident but with no signs of further displacement. The patient was completely satisfied with the outcome and had a painless range of knee flexion between 0-95°. Conclusions We believe that patients undergoing this type of surgery require careful counseling regarding the risk of complications both during and after surgery despite strong evidence supporting improved functional outcomes. PMID:24195600

  11. Case report: multifocal subchondral stress fractures of the femoral heads and tibial condyles in a young military recruit.

    PubMed

    Yoon, Pil Whan; Yoo, Jeong Joon; Yoon, Kang Sup; Kim, Hee Joong

    2012-03-01

    Subchondral stress fractures of the femoral head may be either of the insufficiency-type with poor quality bone or the fatigue-type with normal quality bone but subject to high repetitive stresses. Unlike osteonecrosis, multiple site involvement rarely has been reported for subchondral stress fractures. We describe a case of multifocal subchondral stress fractures involving femoral heads and medial tibial condyles bilaterally within 2 weeks. A 27-year-old military recruit began having left knee pain after 2 weeks of basic training, without any injury. Subsequently, right knee, right hip, and left hip pain developed sequentially within 2 weeks. The diagnosis of multifocal subchondral stress fracture was confirmed by plain radiographs and MR images. Nonoperative treatment of the subchondral stress fractures of both medial tibial condyles and the left uncollapsed femoral head resulted in resolution of symptoms. The collapsed right femoral head was treated with a fibular strut allograft to restore congruity and healed without further collapse. There has been one case report in which an insufficiency-type subchondral stress fracture of the femoral head and medial femoral condyle occurred within a 2-year interval. Because the incidence of bilateral subchondral stress fractures of the femoral head is low and multifocal involvement has not been reported, multifocal subchondral stress fractures can be confused with multifocal osteonecrosis. Our case shows that subchondral stress fractures can occur in multiple sites almost simultaneously.

  12. Functional and radiological evaluations of high-energy tibial plateau fractures treated with double-buttress plate fixation.

    PubMed

    Yu, Z; Zheng, L; Zhang, Y; Li, J; Ma, Bao'an

    2009-05-14

    This study was designed to evaluate the functional and radiological outcomes of patients with complex tibial plateau fractures treated with double-buttress plate fixation. Sixty five cases of complex (Schatzker type V and VI) tibial plateau fractures were treated with double-buttress plate fixation in our centre from September 2001 to September 2006 through two separate plate incisions. Fifty four patients were followed up for a period ranging from 12 to 48 months and evaluated for the functional and radiological outcomes by a series of standard questionnaire and measurement. Due to the good exposure without any extensive soft-tissue dissection of the double-buttress plate fixation, the fractures in all 54 patients were healed and the treatment achieved greater than 90% of satisfactory-to-excellent rates of reduction. The mean time of bone union was 15.4 weeks (range, 12-30 weeks), and the mean time of full weight-bearing was 18.7 weeks (range, 14-26 weeks). At the final follow-up visit, no patients showed knee instability; the mean range of motion was 107.6 degrees (range, 85 degrees -130 degrees ). For all patients, no statistically significant difference in the functional outcomes was observed between their 6-months and final follow-up visits; or in the radiological findings between their immediate postoperative and final follow-up examinations. Double-buttress plate fixation is a feasible treatment option for bilcondylar and complex tibial plateau fractures. Although technically demanding, it offers reliable stability without additional postoperative adjuvant external fixation, and at the same time avoids extensive soft tissue dissection, allowing the early painless range of motion.

  13. Stress fractures of the foot and ankle, part 2: site-specific etiology, imaging, and treatment, and differential diagnosis.

    PubMed

    Mandell, Jacob C; Khurana, Bharti; Smith, Stacy E

    2017-09-01

    Stress fractures of the foot and ankle are a commonly encountered problem among athletes and individuals participating in a wide range of activities. This illustrated review, the second of two parts, discusses site-specific etiological factors, imaging appearances, treatment options, and differential considerations of stress fractures of the foot and ankle. The imaging and clinical management of stress fractures of the foot and ankle are highly dependent on the specific location of the fracture, mechanical forces acting upon the injured site, vascular supply of the injured bone, and the proportion of trabecular to cortical bone at the site of injury. The most common stress fractures of the foot and ankle are low risk and include the posteromedial tibia, the calcaneus, and the second and third metatarsals. The distal fibula is a less common location, and stress fractures of the cuboid and cuneiforms are very rare, but are also considered low risk. In contrast, high-risk stress fractures are more prone to delayed union or nonunion and include the anterior tibial cortex, medial malleolus, navicular, base of the second metatarsal, proximal fifth metatarsal, hallux sesamoids, and the talus. Of these high-risk types, stress fractures of the anterior tibial cortex, the navicular, and the proximal tibial cortex may be predisposed to poor healing because of the watershed blood supply in these locations. The radiographic differential diagnosis of stress fracture includes osteoid osteoma, malignancy, and chronic osteomyelitis.

  14. Postoperative weight bearing and patient reported outcomes at one year following tibial plateau fractures.

    PubMed

    Thewlis, Dominic; Fraysse, Francois; Callary, Stuart A; Verghese, Viju Daniel; Jones, Claire F; Findlay, David M; Atkins, Gerald J; Rickman, Mark; Solomon, Lucian B

    2017-07-01

    Tibial plateau fractures are complex and the current evidence for postoperative rehabilitation is weak, especially related to the recommended postoperative weight bearing. The primary aim of this study was to investigate if loading in the first 12 weeks of recovery is associated with patient reported outcome measures at 26 and 52 weeks postoperative. We hypothesized that there would be no association between loading and patient reported outcome measures. Seventeen patients, with a minimum of 52-week follow-up following fragment-specific open reduction and internal fixation for tibial plateau fracture, were selected for this retrospective analysis. Postoperatively, patients were advised to load their limb to a maximum of 20kg during the first 6 weeks. Loading data were collected during walking using force platforms. A ratio of limb loading (affected to unaffected) was calculated at 2, 6 and 12 weeks postoperative. Knee Injury and Osteoarthritis Scores were collected at 6, 12, 26 and 52 weeks postoperative. The association between loading ratios and patient reported outcomes were investigated. Compliance with weight bearing recommendations and changes in the patient reported outcome measures are described. Fracture reduction and migration were assessed on plain radiographs. No fractures demonstrated any measurable postoperative migration at 52 weeks. Significant improvements were seen in all patient reported outcome measures over the first 52 weeks, despite poor adherence to postoperative weight bearing restrictions. There were no associations between weight bearing ratio and patient reported outcomes at 52 weeks postoperative. Significant associations were identified between the loading ratio at 2 weeks and knee-related quality of life at six months (R 2 =0.392), and between the loading ratio at 6 weeks combined with injury severity and knee-related quality of life at 26 weeks (R 2 =0.441). In summary, weight bearing as tolerated does not negatively affect the

  15. [Ultrabraid SUTURE WITH FOOTPRINT RIVET FOR ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE IN ADOLESCENTS UNDER ARTHROSCOPY].

    PubMed

    Liang, Jinying; Zheng, Jiapeng; Ll, Qiang; Zhong, Shuyu; Chen, Minzhen

    2015-06-01

    To investigate the clinical effects of the Ultrabraid suture with FOOTPRINT rivet by arthroscopic technique for the treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture. Between May 2011 and December 2013, 19 adolescent patients with ACL tibial eminence avulsion fracture were treated with arthroscopic reduction and fixation by Ultrabraid sutures with FOOTPRINT rivet. There were 13 males and 6 females with an average age of 15.8 years (range, 8-18 years). The left knees were involved in 10 cases and the right knees in 9 cases. The injury causes included traffic accident injury in 8 cases, sport injury in 6 cases, and sprain injury in 5 cases. Three patients had old fractures, and the others had fresh fractures. The results of Lachman test and anterior drawer test were both positive. The International Knee Documentation Committee (IKDC) subject score was 54.2 ± 4.0. Based on Meyers-McKeever classification, there were 3 cases of type II, 10 cases of type III, and 6 cases of type IV. The operation time was 50-60 minutes (mean, 55.2 minutes). X-ray film showed satisfactory fracture reduction at 1 day after operation. Primary healing of incision was obtained with no infection. Eighteen patients were followed up for 1-3 years (mean, 1.7 years). All fractures healed with smooth joint surface on the X-ray film at 3 months after operation. The results of Lachman test and anterior drawer test were both negative in 17 cases, and the results was negative for anterior drawer test and was weakly positive for Lachman test in 1 case. The IKDC subject score was significantly improved to 96.1 ± 2.1 at last follow-up (t = 34.600, P = 0.000). It could achieve early restoration of knee joint function to treat the ACL tibial eminence avulsion fracture by arthroscopic technique of the Ultrabraid suture with FOOTPRINT rivet because of satisfactory reduction, reliable fixation, small wound, and early rehabilitation.

  16. Post-Traumatic Periprosthetic Tibial and Fibular Fracture After Total Ankle Arthroplasty: A Case Report.

    PubMed

    Brock, Amanda K; Tan, Eric W; Shafiq, Babar

    Periprosthetic fractures after total ankle arthroplasty are uncommon, with most cases occurring intraoperatively. We describe a post-traumatic periprosthetic fracture of the distal tibia and fibula after total ankle arthroplasty that was treated with minimally invasive plate osteosynthesis. It is important for orthopedic surgeons not only to recognize the risk factors for postoperative periprosthetic total ankle arthroplasty fractures, but also to be familiar with the treatment options available to maximize function and minimize complications. The design of the tibial prosthesis and surgical techniques required to prepare the ankle joint for implantation are important areas of future research to limit the risk of periprosthetic fractures. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  17. The Anteroposterior Axis of the Proximal Tibia Can Change After Tibial Resection in Total Knee Arthroplasty: Computer Simulation Using Asian Osteoarthritis Knees.

    PubMed

    Ushio, Tetsuro; Mizu-Uchi, Hideki; Okazaki, Ken; Ma, Yuan; Kuwashima, Umito; Iwamoto, Yukihide

    2017-03-01

    We evaluated the effect of cutting surface on the anteroposterior (AP) axis of the proximal tibia using a 3-dimensional (3D) bone model to ensure proper tibial rotational alignment in total knee arthroplasty. 3D bone models were reconstructed from the preoperative computed tomography data of 93 Japanese osteoarthritis knees with varus deformity. The AP axis was defined as the perpendicular bisector of the medial and lateral condylar centers in a 3D coordinate system. Bone cutting of the proximal tibia was performed with various tibial posterior slopes (0°, 3°, 7°) to the mechanical axis, and we compared the AP axes before and after bone cutting. The AP axis before bone cutting crossed a point at about 16% (one-sixth) of the distance from the medial edge of the patellar tendon at its tibial attachment. The AP axis after bone cutting was significantly internally rotated at all posterior slopes: 4.1° at slope 0°, 3.0° at slope 3°, and 2.1° at slope 7°. The percentages of cases with differences of more than 3° or 5° were 66.7% and 34.4% at slope 0°, 53.8% and 24.7% at slope 3°, and 38.3% and 11.8% at slope 7°, respectively. The AP axis of the proximal tibia may be rotated internally after resection of the proximal tibia in total knee arthroplasty. Hence, surgeons should recognize the effect of changes in the cutting surface on rotational alignment of the proximal tibia. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Rap system of stress stimulation can promote bone union after lower tibial bone fracture: a clinical research.

    PubMed

    Yao, Jian-fei; Shen, Jia-zuo; Li, Da-kun; Lin, Da-sheng; Li, Lin; Li, Qiang; Qi, Peng; Lian, Ke-jian; Ding, Zhen-qi

    2012-01-01

    Lower tibial bone fracture may easily cause bone delayed union or nonunion because of lacking of dynamic mechanical load. Research Group would design a new instrument as Rap System of Stress Stimulation (RSSS) to provide dynamic mechanical load which would promote lower tibial bone union postoperatively. This clinical research was conducted from January 2008 to December 2010, 92 patients(male 61/female 31, age 16-70 years, mean 36.3 years) who suffered lower tibial bone closed fracture were given intramedullary nail fixation and randomly averagely separated into experimental group and control group(according to the successively order when patients went for the admission procedure). Then researchers analysed the clinical healing time, full weight bearing time, VAS (Visual Analogue Scales) score and callus growth score of Lane-Sandhu in 3,6,12 months postoperatively. The delayed union and nonunion rates were compared at 6 and 12 months separately. All the 92 patients had been followed up (mean 14 months). Clinical bone healing time in experimental group was 88.78±8.80 days but control group was 107.91±9.03 days. Full weight bearing time in experimental group was 94.07±9.81 days but control group was 113.24±13.37 days respectively (P<0.05). The delayed union rate in 6 months was 4.3% in experimental group but 10.9% in control group(P<0.05). The nonunion rate in 12 months was 6.5% in experimental group but 19.6% in control group(P<0.05). In 3, 6, 12 months postoperatively, VAS score and Lane-Sandhu score in experimental group had more significantly difference than them in control group. RSSS can intermittently provide dynamic mechanical load and stimulate callus formation, promote lower tibial bone union, reduce bone delayed union or nonunion rate. It is an adjuvant therapy for promoting bone union after lower tibial bone fracture.

  19. Open tibial fractures grade IIIC treated successfully with external fixation, negative-pressure wound therapy and recombinant human bone morphogenetic protein 7.

    PubMed

    Babiak, Ireneusz

    2014-10-01

    The aim of the therapy in open tibial fractures grade III was to cover the bone with soft tissue and achieve healed fracture without persistent infection. Open tibial fractures grade IIIC with massive soft tissue damage require combined orthopaedic, vascular and plastic-reconstructive procedures. Negative-pressure wound therapy (NPWT), used in two consecutive cases with open fracture grade IIIC of the tibia diaphysis, healed extensive soft tissue defect with exposure of the bone. NPWT eventually allowed for wound closure by split skin graft within 21-25 days. Ilizarov external fixator combined with application of recombinant human bone morphogenetic protein-7 at the site of delayed union enhanced definitive bone healing within 16-18 months. © 2012 The Authors. International Wound Journal © 2012 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  20. [Posttraumatic deformities of the knee joint : Intra-articular osteotomy after malreduction of tibial head fractures].

    PubMed

    Frosch, K-H; Krause, M; Frings, J; Drenck, T; Akoto, R; Müller, G; Madert, J

    2016-10-01

    Malreduction of tibial head fractures often leads to malalignment of the lower extremity, pain, limited range of motion and instability. The extent of the complaints and the degree of deformity requires an exact analysis and a standardized approach. True ligamentous instability should be distinguished from pseudoinstability of the joint. Also extra- and intra-articular deformities have to be differentiated. In intra-articular deformities the extent of articular surface displacement, defects and clefts must be accurately evaluated. A specific surgical approach is necessary, which allows adequate visualization, correct osteotomy and refixation of the fractured area of the tibial head. In the long-term course good clinical results are described for intra-articular osteotomies. If the joint is damaged to such an extent that it cannot be reconstructed or in cases of advanced posttraumatic osteoarthritis, total knee arthroplasty may be necessary; however, whenever possible and reasonable, anatomical reconstruction and preservation of the joint should be attempted.

  1. [Effectiveness of arthroscopic treatment of anterior cruciate ligament tibial eminence avulsion fracture with non-absorbable suture fixation combined with mini-plate].

    PubMed

    Wang, Suiyuan; Xiao, Yang; Tong, Zuoming; Li, Guiqiu; Jiang, Juhua; Yao, Jinghui; Wu, Zhiyong; Li, Tengfei; Wu, Qun

    2013-09-01

    To evaluate the surgical techniques and effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture with non-absorbable suture fixation combined with the miniplate. Between January 2009 and March 2012, 32 patients with ACL tibial eminence avulsion fractures were treated. There were 18 males and 14 females, aged 12-40 years (mean, 17.5 years). The injury causes included traffic accident injury in 15 cases, sport injury in 6 cases, and falling injury in 11 cases. The time from injury to operation ranged 7-18 days with an average of 9.5 days. Before operation, the results of Lachman test were all positive; the Lysholm score was 52.13 +/- 4.22 and the International Knee Documentation Committee (IKDC) score was 44.82 +/- 2.44. According to Meyers-McKeever classification criteria, there were 12 cases of type II and 20 cases of type III. After arthroscopic poking reduction of fracture, tibial eminence avulsion fractures were fixed with the Ethibond non-absorbable sutures bypass figure-of-eight tibial tunnel combined with the metacarpal and phalangeal mini-plate. Primary healing was obtained in all incisions; no joint infection or skin necrosis occurred after operation. All patients were followed up with an average time of 22.4 months (range, 12-50 months). The patients showed negative Lachman test at 12 weeks after operation. Except 3 patients having knee extension limitation at last follow-up, the knee extension range of motion (ROM) was normal in the other patients; the knee flexion ROM was normal in all patients. The Lysholm score and IKDC score were significantly improved to 94.19 +/- 0.93 and 94.35 +/- 1.22 at last follow-up, showing significant differences when compared with preoperative values (t = 55.080, P = 0.000; t = 101.715, P = 0.000). The arthroscopic treatment of ACL tibial eminence avulsion fracture with Ethibond non-absorbable suture fixation combined with mini-plate is an effective procedure with the

  2. The anterolateral acromial approach for fractures of the proximal humerus.

    PubMed

    Gardner, Michael J; Boraiah, Sreevathsa; Helfet, David L; Lorich, Dean G

    2008-02-01

    Displaced and unstable fractures of the proximal humerus are notoriously difficult to manage. Successful surgical treatment requires finding the appropriate balance between adequate exposure for reduction and rigid fixation and minimizing soft tissue dissection. The anterolateral acromial approach was developed to allow less invasive treatment of proximal humerus fractures. The plane of the avascular anterior deltoid raphe is utilized, and the axillary nerve is identified and protected. Anterior dissection near the critical blood supply is avoided, substantial muscle retraction is minimized, and the lateral plating zone is directly accessed. Over a 4-year period, 52 patients with acute displaced fractures of the proximal humerus were treated with the anterolateral acromial approach and either a locking plate or an intramedullary nail. Twenty-three patients were evaluated clinically at a minimum follow-up of 1 year (average, 28 months) by clinical examination for range of motion and nerve function and a QuickDASH score. There were no axillary nerve deficits postoperatively related to the approach, and the average QuickDASH score was 25.2 (0, best; 100, worst). This approach allowed direct access to the lateral fracture planes for fracture reduction and plate placement or safe nail and interlocking screw placement.

  3. Modified rush pin technique for two- or three-part proximal humeral fractures.

    PubMed

    Mallick, A; Hearth, M; Singh, S; Pandey, R

    2008-12-01

    To report the outcomes of modified Rush pin fixation for proximal humeral fractures. 42 men and 20 women aged 19 to 94 (mean, 64) years with 2- or 3-part proximal humeral fractures underwent reduction and fixation using the modified Rush pin technique. 11 patients died from reasons unrelated to the surgery. Of 40 (out of 51) patients completing a subjective functional assessment using an Oxford Shoulder Questionnaire, 28 (70%) had 2-part and 10 (25%) had 3-part displaced fractures, and the remaining 2 (5%) had fracture-dislocations (one being 2-part and one 3-part). 25 (63%) patients were very satisfied (including one with a 3-part fracture after 6 months of rehabilitation), 7 (17%) were moderately satisfied, and 8 (20%) were not satisfied. There were 8 complications, including pin cut-out from the proximal fragment (n=2), proximal pin migration (n=2), distal pin migration (n=1), cortical perforation during surgery (n=1), mild ulnar nerve symptoms (n=1). No patients had non-union, myositis ossificans, avascular necrosis of the humeral head, or axillary nerve injury. The modified Rush pin fixation minimises tissue dissection; the implants are cheap and readily available; and the technical expertise is easily learnt. This technique is a suitable alternative of fixing proximal humeral fractures, especially in the elderly.

  4. Polyaxial Screws in Locked Plating of Tibial Pilon Fractures.

    PubMed

    Yenna, Zachary C; Bhadra, Arup K; Ojike, Nwakile I; Burden, Robert L; Voor, Michael J; Roberts, Craig S

    2015-08-01

    This study examined the axial and torsional stiffness of polyaxial locked plating techniques compared with fixed-angle locked plating techniques in a distal tibia pilon fracture model. The effect of using a polyaxial screw to cross the fracture site was examined to determine its ability to control relative fracture site motion. A laboratory experiment was performed to investigate the biomechanical stiffness of distal tibia fracture models repaired with 3.5-mm anterior polyaxial distal tibial plates and locking screws. Sawbones Fourth Generation Composite Tibia models (Pacific Research Laboratories, Inc, Vashon, Washington) were used to model an Orthopaedic Trauma Association 43-A1.3 distal tibia pilon fracture. The polyaxial plates were inserted with 2 central locking screws at a position perpendicular to the cortical surface of the tibia and tested for load as a function of axial displacement and torque as a function of angular displacement. The 2 screws were withdrawn and inserted at an angle 15° from perpendicular, allowing them to span the fracture and insert into the opposing fracture surface. Each tibia was tested again for axial and torsional stiffness. In medial and posterior loading, no statistically significant difference was found between tibiae plated with the polyaxial plate and the central screws placed in the neutral position compared with the central screws placed at a 15° position. In torsional loading, a statistically significant difference was noted, showing greater stiffness in tibiae plated with the polyaxial plate and the central screws placed at a 15° position compared with tibiae plated with the central screws placed at a 0° (or perpendicular) position. This study showed that variable angle constructs show similar stiffness properties between perpendicular and 15° angle insertions in axial loading. The 15° angle construct shows greater stiffness in torsional loading. Copyright 2015, SLACK Incorporated.

  5. Lateral X-ray for proximal femoral fractures - Is it really necessary?

    PubMed

    Riaz, Osman; Nisar, Sohail; Arshad, Rizwan; Vanker, Raees

    2016-10-01

    Historically routine work up of a patient with a proximal femoral fracture always included anterior-posterior (AP) and a lateral film of the hip. The aim was to define the role of the lateral X-ray in the assessment and surgical planning of proximal femur fractures. Radiographs of 320 consecutive patients with proximal femoral fractures who were admitted over a 12 months period were divided into lateral and AP views. Two blinded reviewers independently assessed the AP view alone and then the AP plus the lateral view. Fracture classification was noted for each X-ray and then compared with intraoperative diagnosis which was our study's gold standard. A 2 × 2 contingency square table and Pearson's x(2) test were used for statistical analysis. The rate of correct classification by the reviewers enhanced by the assessment of the lateral X-ray in addition to the AP view for intracapsular fractures (p = 0.018) but not for extracapsular fractures (p = 0.29). Operative management did not change for intracapsular fractures which appeared displaced on initial AP view after reviewing the lateral X-ray. The only advantage of obtaining a lateral view in intracapsular fracture was the detection of displacement were the fracture appeared to be undisplaced on initial AP view. This study provides statistical evidence that one view is adequate and safe for majority of proximal femoral fractures. The lateral radiograph should not be performed on a routine basis thus making considerable saving in time and money, and avoiding unnecessary radiation exposure and discomfort to the patient. Copyright © 2015 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  6. [A case of anterior tibial arteriovenous fistula after closed fracture of the leg].

    PubMed

    Touzard, R C

    1975-01-01

    This case permits one to emphasize the great rareness of arteriovenous fistula after closed fractures of the shaft of the tibia. Fistulas in this anterior tibial position are remarkably latent, cause no symptoms below the fistula nor symptoms of heart failure. Treatment by several ligatures, permitted this patient to return to work 15 days after operation without any further treatment. The patient no longer has any symptoms.

  7. Balloon osteoplasty--a new technique for reduction and stabilisation of impression fractures in the tibial plateau: a cadaver study and first clinical application.

    PubMed

    Ahrens, Philipp; Sandmann, Gunther; Bauer, Jan; König, Benjamin; Martetschläger, Frank; Müller, Dirk; Siebenlist, Sebastian; Kirchhoff, Chlodwig; Neumaier, Markus; Biberthaler, Peter; Stöckle, Ulrich; Freude, Thomas

    2012-09-01

    Fractures of the tibial plateau are among the most severe injuries of the knee joint and lead to advanced gonarthrosis if the reduction does not restore perfect joint congruency. Many different reduction techniques focusing on open surgical procedures have been described in the past. In this context we would like to introduce a novel technique which was first tested in a cadaver setup and has undergone its successful first clinical application. Since kyphoplasty demonstrated effective ways of anatomical correction in spine fractures, we adapted the inflatable instruments and used the balloon technique to reduce depressed fragments of the tibial plateau. The technique enabled us to restore a congruent cartilage surface and bone reduction. In this technique we see a useful new method to reduce depressed fractures of the tibial plateau with the advantages of low collateral damage as it is known from minimally invasive procedures.

  8. Asymmetry in gait pattern following bicondylar tibial plateau fractures-A prospective one-year cohort study.

    PubMed

    Elsoe, Rasmus; Larsen, Peter

    2017-07-01

    Despite the high number of studies evaluating outcomes following tibial plateau fractures, the literature lacks studies including the objective assessment of gait pattern. The purpose of the present study was to evaluate asymmetry in gait patterns at 12 months after frame removal following ring fixation of a tibial plateau fracture. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns 12 months after frame removal measured with a pressure-sensitive mat. The mat registers footprints and present gait speed, cadence, as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. Twenty-three patients were included with a mean age of 54.4 years (32-78 years). Patients presented with a shorter step-length of the injured leg compared to the non-injured leg (asymmetry of 11.3%). Analysis of single-support showed shorter support time of the injured leg compared to the non-injured leg (asymmetry of 8.7%). Moreover, analysis of swing-time showed increased swing-time of the injured leg (asymmetry of 8.9%). Compared to a healthy reference population, increased asymmetry in all gait patterns was observed. The association between asymmetry and health-related quality of life (HRQOL) showed moderate associations (single-support: R=0.50, P=0.03; step-length: R=0.43, P=0.07; swing-time: R=0.46, P=0.05). Compared to a healthy reference population, gait asymmetry is common 12 months after frame removal in patients treated with external ring fixation following a tibial plateau fracture of the tibia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Bilateral trampoline fracture of the proximal tibia in a child.

    PubMed

    Arkink, Enrico B; van der Plas, Annelies; Sneep, Ruth W; Reijnierse, Monique

    2017-12-01

    Trampoline fractures are transversely oriented impaction fractures of the proximal tibia sustained by young children jumping on a trampoline. Unaware of the mechanism of this specific nontraumatic fracture, physicians may fail to detect these fractures on plain radiographs, as radiological findings may be very subtle. In this case report, we present a rare case of bilateral trampoline fractures with an explanation of the trauma mechanism.

  10. A high rate of tibial plateau fractures after early experience with patient-specific instrumentation for unicompartmental knee arthroplasties.

    PubMed

    Leenders, A M; Schotanus, M G M; Wind, R J P; Borghans, R A P; Kort, N P

    2018-04-30

    Patient-specific instrumentation (PSI) for unicompartmental knee arthroplasty (UKA) has been available for a few years. However, limited literature is available on this subject. Hence, the aim of this cohort study is to evaluate the 2 years' results of our first experiences with the use of PSI in UKA. It is hypothesised that there is no advantage in rate of adverse events and in radiological and functional outcomes in comparison to literature on the conventional method. This cohort included 129 knees of 122 patients, operated by one surgeon. Outcome measures were the rate of adverse events (AEs); implant position as determined on radiographs; the accuracy of the default and approved planning of the implant sizes and the patient-reported outcome measures (PROMs) preoperatively, and at 3, 12 and 24 months, postoperatively. A total of 6 (4.9%) AEs were observed in this study, with 4 (3.3%) tibial fractures being the main complication. The mean postoperative biomechanical axis was 176.4° and in the majority of cases, the radiographic criteria, as determined by the manufacturer, were met. The tibial component showed 20 (16.4%) outliers in the sagittal and 3 (2.5%) outliers in the frontal plane. There were no outliers of the femoral component. For the femoral and tibial components, respectively, in 125 (96.9%) and 79 (61.7%) cases, there was an agreement between approved planning and implanted component size. All PROMs improved significantly after surgery. Tibial fracture was the most common AE, probably related to the transition from cemented to uncemented UKA. Perioperative modifications to the surgical technique were made in order to prevent this AE. Improvements should be made to the operation technique of the uncemented tibial plateau to obtain an adequate placement and at the same time reduce the risk for tibial fracture. The PSI technique was a reliable tool for the placement of the femoral component. Functional outcome was in line with literature on the

  11. Tension band plating of a nonunion anterior tibial stress fracture in an athlete.

    PubMed

    Merriman, Jarrad A; Villacis, Diego; Kephart, Curtis J; Rick Hatch, George F

    2013-07-01

    The authors present a rare technique of tension band plating of the anterior tibia in the setting of a nonunion stress fracture. Surgical management with an intramedullary nail is a viable and proven option for treating such injuries. However, in treating elite athletes, legitimate concerns exist regarding the surgical disruption of the extensor mechanism and the risk of anterior knee pain associated with intramedullary nail use. The described surgical technique demonstrates the use of tension band plating as an effective treatment of delayed union and nonunion anterior tibial stress fractures in athletes without the potential risks of intramedullary nail insertion. Copyright 2013, SLACK Incorporated.

  12. [Comparison study on locking compress plate external fixator and standard external fixator for treatment of tibial open fractures].

    PubMed

    Wu, Gang; Luo, Xiaozhong; Tan, Lun; Lin, Xu; Wu, Chao; Guo, Yong; Zhong, Zewei

    2013-11-01

    To compare the clinical results of locking compress plate (LCP) as an external fixator and standard external fixator for treatment of tibial open fractures. Between May 2009 and June 2012, 59 patients with tibial open fractures were treated with LCP as an external fixator in 36 patients (group A), and with standard external fixator in 23 patients (group B). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, location, and interval between injury and surgery between 2 groups (P > 0.05). The time of fracture healing and incision healing, the time of partial weight-bearing, the range of motion (ROM) of knee and ankle, and complications were compared between 2 groups. The incidence of pin-track infection in group A (0) was significantly lower than that in group B (21.7%) (P=0.007). No significant difference was found in the incidence of superficial infection and deep infection of incision, and the time of incision healing between 2 groups (P > 0.05). Deep vein thrombosis occurred in 5 cases of group A and 2 cases of group B, showing no significant difference (Chi(2)=0.036, P=0.085). All patients were followed up 15.2 months on average (range, 9-28 months) in group A, and 18.6 months on average (range, 9-47 months) in group B. The malunion rate and nonunion rate showed no significant difference between groups A and B (0 versus 13.0% and 0 versus 8.7%, P > 0.05); the delayed union rate of group A (2.8%) was significantly lower than that of group B (21.7%) (Chi(2)=5.573, P=0.018). Group A had shorter time of fracture healing, quicker partial weight-bearing, greater ROM of the knee and ankle than group B (P < 0.05). The LCP external fixator can obtain reliable fixation in treating tibial open fracture, and has good patients' compliance, so it is helpful to do functional exercise, improve fracture healing and function recovery, and reduce the complication incidence.

  13. The influence of procedure delay on resource use: a national study of patients with open tibial fracture.

    PubMed

    Sears, Erika Davis; Burke, James F; Davis, Matthew M; Chung, Kevin C

    2013-03-01

    The purpose of this study was to (1) understand national variation in delay of emergency procedures in patients with open tibial fracture at the hospital level and (2) compare length of stay and cost in patients cared for at the best- and worst-performing hospitals for delay. The authors retrospectively analyzed the 2003 to 2009 Nationwide Inpatient Sample. Adult patients with open tibial fracture were included. Hospital probability of delay in performing emergency procedures beyond the day of admission was calculated. Multilevel linear regression random-effects models were created to evaluate the relationship between the treating hospital's tendency for delay (in quartiles) and the log-transformed outcomes of length of stay and cost. The final sample included 7029 patients from 332 hospitals. Patients treated at hospitals in the fourth (worst) quartile for delay were estimated to have 12 percent (95 percent CI, 2 to 21 percent) higher cost compared with patients treated at hospitals in the first quartile. In addition, patients treated at hospitals in the fourth quartile had an estimated 11 percent (95 percent CI, 4 to 17 percent) longer length of stay compared with patients treated at hospitals in the first quartile. Patients with open tibial fracture treated at hospitals with more timely initiation of surgical care had lower cost and shorter length of stay than patients treated at hospitals with less timely initiation of care. Policies directed toward mitigating variation in care may reduce unnecessary waste.

  14. Human parathyroid hormone-(1-38) restores cancellous bone to the immobilized, osteopenic proximal tibial metaphysis in rats

    NASA Technical Reports Server (NTRS)

    Ma, Y. F.; Jee, W. S.; Ke, H. Z.; Lin, B. Y.; Liang, X. G.; Li, M.; Yamamoto, N.

    1995-01-01

    The purpose of this study was to determine if human parathyroid hormone-(1-38) (hPTH(1-38)) can restore cancellous bone mass to the established osteopenic, immobilized proximal tibial metaphyses of female rats. The right hindlimbs of 6-month-old female Sprague-Dawley rats were immobilized by bandaging the right hindlimbs to the abdomen. After 30 days of right hindlimb immobilization, the rats were subcutaneously injected with 200 micrograms hPTH(1-38)/kg/day for 15 days (short-term treatment) or 75 days (longer-term treatment). Static bone histomorphometry was performed on the primary spongiosa, and both static and dynamic histomorphometry were performed on the secondary spongiosa of the right proximal tibial metaphyses. Immobilization for 30 days without treatment decreased trabecular bone area, number, and thickness in both primary and secondary spongiosa, and induced an increase in eroded perimeter and a decrease in tissue referent-bone formation rate in the secondary spongiosa. These changes reached a new steady state thereafter. Treatment with 200 micrograms hPTH(1-38)/kg/day for 15 days, beginning 30 days after immobilization, significantly increased trabecular bone area, thickness, and number in both primary and secondary spongiosa despite continuous immobilization when compared with controls. The short-term PTH treatment (15 days) significantly increased labeling perimeter, mineral apposition rate, and tissue referent-bone formation rate in the secondary spongiosa and stimulated longitudinal bone growth as compared with the controls. Longer PTH treatment (75 days) further increased trabecular bone area, thickness, and number as compared with controls and groups given short-term PTH treatment (15 days). The bone formation indices in the secondary spongiosa of the longer-term treated rats were lower than those of the short-term treated group, but they were still higher than those of controls. Our findings indicate that PTH treatment stimulates cancellous bone

  15. Intramedullary Percutaneous Fixation of Extra-Articular Proximal and Middle Phalanx Fractures.

    PubMed

    Jovanovic, Nebojsa; Aldlyami, Ehab; Saraj, Basem; Fm Seidam, Mohamed; Badawi, Hamed; Shaat, Ahmed; Alawadi, Khalid; Dodakundi, Chaitanya

    2018-06-01

    Multiple methods have been described for treating unstable proximal and middle phalangeal fractures. Irrespective of using an open or closed technique of fixation, stiffness and extensor lag at the proximal/distal interphalangeal joint almost always occur. This issue can be avoided by allowing the patients to mobilize the fingers out of plaster or splint as early as possible from the day of surgery. We describe a technique of intramedullary percutaneous fixation of extra-articular proximal and middle phalanx fractures allowing immediate mobilization of fingers, concurrent stabilization with progressive healing and thus preventing such complications.

  16. The Lymphatic Response to Injury with Soft-Tissue Reconstruction in High-Energy Open Tibial Fractures of the Lower Extremity.

    PubMed

    van Zanten, Malou C; Mistry, Raakhi M; Suami, Hiroo; Campbell-Lloyd, Andrew; Finkemeyer, James P; Piller, Neil B; Caplash, Yugesh

    2017-02-01

    Severe compound tibial fractures are associated with extensive soft-tissue damage, resulting in disruption of lymphatic pathways that leave the patient at risk of developing chronic lymphedema. There are limited data on lymphatic response following lower limb trauma. Indocyanine green fluorescence lymphography is a novel, real-time imaging technique for superficial lymphatic mapping. The authors used this technique to image the superficial lymphatic vessels of the lower limbs in patients with severe compound tibial fracture. Baseline demographics and clinical and operative details were recorded in a prospective cohort of 17 patients who had undergone bone and soft-tissue reconstruction after severe compound tibial fracture between 2009 and 2014. Normal lymphatic images were obtained from the patients' noninjured limbs as a control. In this way, the authors investigated any changes to the normal anatomy of the lymphatic system in the affected limbs. Of the 17 patients, eight had free muscle flaps with split-thickness skin grafting, one had a free fasciocutaneous flap, one had a full-thickness skin graft, six had local fasciocutaneous flaps, and one had a pedicled gastrocnemius flap. None of the free flaps demonstrated any functional lymphatic vessels; the fasciocutaneous flaps and the skin graft demonstrated impaired lymphatic vessel function and dermal backflow pattern similar to that in lymphedema. Local flaps demonstrated lymphatic blockage at the scar edge. Severe compound fractures and the associated soft-tissue injury can result in significant lymphatic disruption and an increased risk for the development of chronic lymphedema.

  17. Fracture through a geode in the proximal ulna.

    PubMed

    Wordsworth, B P; Mowat, A G; Watson, N A

    1984-05-01

    Chronic joint pain in rheumatoid arthritis may mask that from other causes. Stress fractures, particularly in osteoporotic lower limb bones of such patients, are well described but can still cause diagnostic difficulty. These difficulties were highlighted by a case in which an unusual fracture occurred through a geode in the proximal ulna mimicking an exacerbation of synovitis in the elbow joint.

  18. Proximal femoral fractures: Principles of management and review of literature.

    PubMed

    Mittal, Ravi; Banerjee, Sumit

    2012-06-01

    The purpose of this study was to review the principles involved in the management of proximal femoral fractures as reported in the literature. A medical literature search in the MEDLINE (PubMed) and Cochrane database was undertaken to review strategies and principles in proximal femoral fracture treatment. Randomized control trials and meta analysis were given preference while case reports/small series were rejected. Early anatomical reduction and surgical fixation remains the best option to reduce the risk of complications like non-union and avascular necrosis in treating fracture neck femurs. Cancellous screws continue to be the preferred treatment for fixation of neck femur fractures in younger population until the benefit of using sliding hip screws is validated by large multicentric studies. In the geriatric age group, early prosthetic replacement brings down the mortality and morbidity associated with neck femur fractures. Sliding hip screw (DHS) is the best available option for stable inter trochanteric fractures. The use of intramedullary nails e.g. PFN is beneficial in treating inter trochanteric fractures with comminution and loss of lateral buttress. Intramedullary implants have been proven to have increased success rates in subtrochanteric fractures and should be preferred over extramedullary plate fixation systems.

  19. Role of Joshi's external stabilization system with percutaneous screw fixation in high-energy tibial condylar fractures associated with severe soft tissue injuries.

    PubMed

    Gupta, Ashish-Kumar; Sapra, Rahul; Kumar, Rakesh; Gupta, Som-Prakash; Kaushik, Devwart; Gaba, Sahil; Bansal, Mahesh Chand; Dayma, Ratan Lal

    2015-01-01

    The treatment of high-energy tibial condylar fractures which are associated with severe soft tissue injuries remains contentious and challenging. In this study, we assessed the results of Joshi's external stabilization system (JESS) by using the principle of ligamentotaxis and percutaneous screw fixation for managing high-energy tibial condylar fractures associated with severe soft tissue injuries. Between June 2008 and June 2010, 25 consecutive patients who were 17e71 years (mean, 39.7), underwent the JESS fixation for high-energy tibial condylar fractures associated with severe soft tissue injuries. Out of 25 patients, 2 were lost during follow-up and in 1 case early removal of frame was done, leaving 22 cases for final follow-up. Among them, 11 had poor skin condition with abrasions and blisters and 2 were open injuries (Gustilo-Anderson grade I&II). The injury mechanisms were motor vehicle accidents (n=19), fall from a height (n=2) and assault (n=1). The fractures were classified according to Schatzker classification system. There were 7 type-V, 14 type-VI and 1 type-lV Schatzker's tibial plateau fractures. The average interval between the injury and surgery was 6.8 days (range 2-13). The average hospital stay was 13 days (range, 7-22). The average interval between the surgery and full weight bearing was 13.6 weeks (range 11-20). The average range of knee flexion was 121°(range 105°-135°). The normal extension of the knee was observed in 20 patients, and an extensor lag of 5°-8° was noted in 2 patients. The complications included superficial pin tract infections (n=4) with no knee stiffness. JESS with lag screw fixation combines the benefit of traction, external fixation, and limited internal fixation, at the same time as allowing the ease of access to the soft tissue for wound checks, pin care, dressing changes, measurement of compartment pressure, and the monitoring of the neurovascular status. In a nutshell, JESS along with screw fixation offers a

  20. Minimizing Alteration of Posterior Tibial Slope During Opening Wedge High Tibial Osteotomy: a Protocol with Experimental Validation in Paired Cadaveric Knees

    PubMed Central

    Westermann, Robert W; DeBerardino, Thomas; Amendola, Annunziato

    2014-01-01

    Introduction The High Tibial Osteotomy (HTO) is a reliable procedure in addressing uni- compartmental arthritis with associated coronal deformities. With osteotomy of the proximal tibia, there is a risk of altering the tibial slope in the sagittal plane. Surgical techniques continue to evolve with trends towards procedure reproducibility and simplification. We evaluated a modification of the Arthrex iBalance technique in 18 paired cadaveric knees with the goals of maintaining sagittal slope, increasing procedure efficiency, and decreasing use of intraoperative fluoroscopy. Methods Nine paired cadaveric knees (18 legs) underwent iBalance medial opening wedge high tibial osteotomies. In each pair, the right knee underwent an HTO using the modified technique, while all left knees underwent the traditional technique. Independent observers evaluated postoperative factors including tibial slope, placement of hinge pin, and implant placement. Specimens were then dissected to evaluate for any gross muscle, nerve or vessel injury. Results Changes to posterior tibial slope were similar using each technique. The change in slope in traditional iBalance technique was -0.3° ±2.3° and change in tibial slope using the modified iBalance technique was -0.4° ±2.3° (p=0.29). Furthermore, we detected no differences in posterior tibial slope between preoperative and postoperative specimens (p=0.74 traditional, p=0.75 modified). No differences in implant placement were detected between traditional and modified techniques. (p=0.85). No intraoperative iatrogenic complications (i.e. lateral cortex fracture, blood vessel or nerve injury) were observed in either group after gross dissection. Discussion & Conclusions Alterations in posterior tibial slope are associated with HTOs. Both traditional and modified iBalance techniques appear reliable in coronal plane corrections without changing posterior tibial slope. The present modification of the Arthrex iBalance technique may increase the

  1. Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite element model.

    PubMed

    Scott, C E H; Eaton, M J; Nutton, R W; Wade, F A; Evans, S L; Pankaj, P

    2017-01-01

    Up to 40% of unicompartmental knee arthroplasty (UKA) revisions are performed for unexplained pain which may be caused by elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on bone strain in a cemented fixed-bearing medial UKA using a finite element model (FEM) validated experimentally by digital image correlation (DIC) and acoustic emission (AE). A total of ten composite tibias implanted with all-polyethylene (AP) and metal-backed (MB) tibial components were loaded to 2500 N. Cortical strain was measured using DIC and cancellous microdamage using AE. FEMs were created and validated and polyethylene thickness varied from 6 mm to 10 mm. The volume of cancellous bone exposed to < -3000 µε (pathological loading) and < -7000 µε (yield point) minimum principal (compressive) microstrain and > 3000 µε and > 7000 µε maximum principal (tensile) microstrain was computed. Experimental AE data and the FEM volume of cancellous bone with compressive strain < -3000 µε correlated strongly: R = 0.947, R 2 = 0.847, percentage error 12.5% (p < 0.001). DIC and FEM data correlated: R = 0.838, R 2 = 0.702, percentage error 4.5% (p < 0.001). FEM strain patterns included MB lateral edge concentrations; AP concentrations at keel, peg and at the region of load application. Cancellous strains were higher in AP implants at all loads: 2.2- (10 mm) to 3.2-times (6 mm) the volume of cancellous bone compressively strained < -7000 µε. AP tibial components display greater volumes of pathologically overstrained cancellous bone than MB implants of the same geometry. Increasing AP thickness does not overcome these pathological forces and comes at the cost of greater bone resection.Cite this article: C. E. H. Scott, M. J. Eaton, R. W. Nutton, F. A. Wade, S. L. Evans, P. Pankaj. Metal-backed versus all-polyethylene unicompartmental knee arthroplasty: Proximal tibial strain in an experimentally validated finite

  2. Gait characteristics before hardware removal in patients operated upon for tibial plateau fractures.

    PubMed

    Deleanu, Bogdan; Prejbeanu, Radu; Crisan, Dan; Predescu, Vlad; Popa, Iulian; Poenaru, Dan V

    2015-07-01

    The reporting of gait analysis data on operated fractures of the tibial plateau, while extensive for studies of knee osteoarthritis of mostly undisclosed aetiology and ACL deficient knees, is rather limited in literature. In the present study we investigated 25 tibial plateau fractures classified as Schatzker II, IV, V and VI that underwent operative reduction and lateral plate osteosynthesis. Apart from routine radiographic exploration and patient completed (KOOS) scores at three (mean of 3.2 months), six (mean of 5.6 months) and 12 months (mean of 11.3 months) postoperatively, gait analysis was performed at these intervals as well. Cadence, step time and knee flexion were the gait parameters that were selected for the comparison at six and 12 months postoperatively. The analysed gait parameters were significantly improved between the six and the 12-month session and statistically significant differences were found between the two groups of values. Cadence had a mean value of 41 steps/minute at six months and 45 steps/minute at 12 months (p = 0.99). Step time was a mean of 0.74 seconds at six months while at 12 months the median value was 0.66 seconds (p = 0.94). Knee flexion angles evolved in a similar manner with mean values of 58° at six months and 69° at 12 months (p = 0.95). The mean KOOS scores were 42.4, 56.3 and 67.99 at three, six and 12 months postoperatively, respectively. Complex intra-articular fractures, classified as Schatzker IV, V and VI, had a higher impact on joint function than Schatzker II fractures treated with similar techniques and implants. There were statistically significant improvements in the recovery status at 12 months postoperatively compared to six months with extended chances for improvement.

  3. Effect of seasonality, weather and holidays on the incidence of proximal hip fracture.

    PubMed

    Koren, Lior; Barak, Adi; Norman, Doron; Sachs, Ofer; Peled, Eli

    2014-05-01

    Proximal hip fractures in the elderly are common and place a heavy burden on health resources. Researching the timing of these fractures could contribute to diverting resources towards peaks in incidence and investing in prevention at certain times. To examine the effect of seasonality, weather and Jewish holidays on hip fracture incidence in older adults. The study population comprised 2050 patients aged 65 years or more who sustained a proximal hip fracture. The computerized files of the patients were reviewed for trends in incidence by season, precipitation, minimum and maximum temperatures, day of the week, and certain Jewish festivals. Hip fractures were more likely to occur in the winter than in the summer (P < 0.0001). Factors that significantly correlated with hip fracture were the maximum daily temperature (r = -0.746, P = 0.005) followed by the minimum daily temperature (r = -0.740, P = 0.006) and precipitation (r = 0.329, P = 0.02). There were fewer fractures on Saturdays (the Sabbath) as compared to other days of the week (P = 0.045). Researching the incidence on Jewish holidays, we found an elevated incidence on Passover (P < 0.0001) and a reduced incidence on the Day of Atonement (Yom Kippui) (P = 0.013). In older people there is an elevated incidence of proximal hip fractures during the winter and on the Jewish festivals. On weekends and on the Day of Atonement the incidence of proximal hip fractures was reduced.

  4. [Medial versus lateral plating in distal tibial fractures: a prospective study of 40 fractures].

    PubMed

    Encinas-Ullán, C A; Fernandez-Fernandez, R; Rubio-Suárez, J C; Gil-Garay, E

    2013-01-01

    Tibial plafond fractures are one of the most challenging injuries in orthopaedic surgery. Their results could be improved by following the new guidelines for the management, and modern plating techniques. The results and complication rate between anteromedial and anterolateral approach for open reduction and internal fixation of these fractures were compared. A study was conducted on 40 patients treated by open reduction an internal fixation between 2007 and 2008. The surgical approach was selected by the surgeon in charge, depending on fracture pattern and skin situation. Patients were evaluated clinically and radiographically by an independent orthopaedic surgeon, not involved in the surgical procedure, using clinical (American Orthopaedic Foot and Ankle Society score) and radiological criteria at a minimum of two years. The appearance of complications after both approaches was recorded. Forty patients were included. The mean age was 53 years, with 24 males and 16 females. Seventeen of the injuries were of high energy, and there were 8 open fractures (3 of type i, 4 type ii and one type iii), and 12 of the closed injuries were grade ii or iii in the Tscherne classification. Six patients (15%) had associated injuries. At final follow-up there were 33 (82%) excellent or good results. No statistical differences were found between either surgical approach regarding time to bone union, rate of delayed union and infection rate. Three plates of the anteromedial group and none of the anterolateral group needed to be removed. Open reduction and internal fixation of distal tibia fractures produced reliable results, with no statistical differences found between anteromedial and anterolateral surgical approaches. Clinical and radiological results and complication rate were mainly related to the fracture type. Copyright © 2012 SECOT. Published by Elsevier Espana. All rights reserved.

  5. The Influence of Procedure Delay on Resource Utilization: A National Study of Patients with Open Tibial Fracture

    PubMed Central

    Sears, Erika Davis; Burke, James F.; Davis, Matthew M.; Chung, Kevin C.

    2016-01-01

    Background The purpose of this study is to 1) understand national variation in delay of emergency procedures in patients with open tibial fracture at the hospital level and 2) compare length of stay (LOS) and cost in patients cared for at the best and worst performing hospitals for delay. Methods We retrospectively analyzed the 2003 – 2009 Nationwide Inpatient Sample. Adult patients with primary diagnosis of open tibial fracture were selected for inclusion. We calculated hospital probability of delay of emergency procedures beyond the day of admission (day 0). Multilevel linear regression random effects models were created to evaluate the relationship between the treating hospital’s tendency for delay (in quartiles) and the log-transformed outcomes of LOS and cost, while adjusting for patient and hospital variables. Results The final sample included 7,029 patients from 332 hospitals. Adjusted analyses demonstrate that patients treated at hospitals in the fourth (worst) quartile for delay were estimated to have 12% (95% CI 2–21%) higher cost compared to patients treated at hospitals in the first quartile. In addition, patients treated at hospitals in the fourth quartile had an estimated 11% (CI 4–17%) longer LOS compared to patients treated at hospitals in the first quartile. Conclusions Patients with open tibial fracture treated at hospitals with more timely initiation of surgical care had lower cost and shorter LOS than patients treated at hospitals with less timely initiation of care. Policies directed toward mitigating variation in care are not only beneficial for patient outcomes, but may also reduce unnecessary waste. Level II (Prognostic) PMID:23142940

  6. Comparison of arthroscopic reduction and percutaneous fixation and open reduction and internal fixation for tibial plateau fractures.

    PubMed

    Sun, Yufu; Sun, Kai; Jiang, Wenxue

    2018-06-01

    To conduct a meta-analysis with randomized controlled trials (RCTs) published in full text to demonstrate database to show the associations of perioperative, postoperative outcomes of arthroscopic reduction and percutaneous fixation(ARPF) and open reduction and internal fixation(ORIF) for tibial plateau fractures to provide the predictive diagnosis for clinic. Literature search was performed in PubMed, Embase, Web of Science and Cochrane Library for information from the earliest date of data collection to June 2017. RCTs comparing the benefits and risks of ARPF with those of ORIF in tibial plateau fractures were included. Statistical heterogeneity was quantitatively evaluated by X 2 test with the significance set P < 0.10 or I 2  > 50%. Seven RCTs consisting of 571 patients were included.(288 ARPF patients; 283 ORIF patients;). Pooled results showed that ORIF was related to a greater increase in operative time, incision length, hospital stay, perioperative complications, and full weight bearing compared with ARPF. The results showed that ARPF was related to a greater increase in ROM Rasmussen Scores compared with ORIF (WMD = 10.38; 95% CI, 8.31, 12.45; P < 0.10). This meta-analysis showed that arthroscopic reduction and percutaneous fixation for tibial plateau fractures, compared with open reduction and internal fixation, could demonstrate an decreased risk of perioperative and postoperative complications and improve clinical outcome in operative time, incision length, hospital stay, perioperative complications, full weight bearing and Rasmussen Scores. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Stress fractures about the tibia, foot, and ankle.

    PubMed

    Shindle, Michael K; Endo, Yoshimi; Warren, Russell F; Lane, Joseph M; Helfet, David L; Schwartz, Elliott N; Ellis, Scott J

    2012-03-01

    In competitive athletes, stress fractures of the tibia, foot, and ankle are common and lead to considerable delay in return to play. Factors such as bone vascularity, training regimen, and equipment can increase the risk of stress fracture. Management is based on the fracture site. In some athletes, metabolic workup and medication are warranted. High-risk fractures, including those of the anterior tibial diaphysis, navicular, proximal fifth metatarsal, and medial malleolus, present management challenges and may require surgery, especially in high-level athletes who need to return to play quickly. Noninvasive treatment modalities such as pulsed ultrasound and extracorporeal shock wave therapy may have some benefit but require additional research.

  8. Proximal femoral fractures: Principles of management and review of literature

    PubMed Central

    Mittal, Ravi; Banerjee, Sumit

    2012-01-01

    Purpose The purpose of this study was to review the principles involved in the management of proximal femoral fractures as reported in the literature. Methods: A medical literature search in the MEDLINE (PubMed) and Cochrane database was undertaken to review strategies and principles in proximal femoral fracture treatment. Randomized control trials and meta analysis were given preference while case reports/small series were rejected. Results and conclusions: Early anatomical reduction and surgical fixation remains the best option to reduce the risk of complications like non-union and avascular necrosis in treating fracture neck femurs. Cancellous screws continue to be the preferred treatment for fixation of neck femur fractures in younger population until the benefit of using sliding hip screws is validated by large multicentric studies. In the geriatric age group, early prosthetic replacement brings down the mortality and morbidity associated with neck femur fractures. Sliding hip screw (DHS) is the best available option for stable inter trochanteric fractures. The use of intramedullary nails e.g. PFN is beneficial in treating inter trochanteric fractures with comminution and loss of lateral buttress. Intramedullary implants have been proven to have increased success rates in subtrochanteric fractures and should be preferred over extramedullary plate fixation systems. PMID:25983451

  9. The effect of plate position and size on tibial slope in high tibial osteotomy: a cadaveric study.

    PubMed

    Rubino, L Joseph; Schoderbek, Robert J; Golish, S Raymond; Baumfeld, Joshua; Miller, Mark D

    2008-01-01

    Opening wedge high tibial osteotomies are performed for degenerative changes and varus. Opening wedge osteotomies can change proximal tibial slope in the sagittal plane, possibly imparting stability in the ACL-deficient knee. The aim of this study was to assess the effect of plate position and size on change in tibial slope. Eight cadaveric knees underwent opening wedge high tibial osteotomy with Puddu plates of each different size. Plates were placed anterior, central, and posterior for each size used. Lateral radiographs were obtained. Tibial slope was measured and compared with baseline slope. Tibial slope was affected by plate position (P < 0.05) and size (P < 0.001). Smaller, posterior plates had less effect on tibial slope. However, anterior and central plates increased tibial slope over all plate sizes (P < 0.05). This study found that tibial slope increases with opening wedge high tibial osteotomy. Larger corrections and anterior placement of the plate are associated with larger increases in slope.

  10. The floating knee: a review on ipsilateral femoral and tibial fractures

    PubMed Central

    Muñoz Vives, Josep; Bel, Jean-Christophe; Capel Agundez, Arantxa; Chana Rodríguez, Francisco; Palomo Traver, José; Schultz-Larsen, Morten; Tosounidis, Theodoros

    2016-01-01

    In 1975, Blake and McBryde established the concept of ‘floating knee’ to describe ipsilateral fractures of the femur and tibia.1 This combination is much more than a bone lesion; the mechanism is usually a high-energy trauma in a patient with multiple injuries and a myriad of other lesions. After initial evaluation patients should be categorised, and only stable patients should undergo immediate reduction and internal fixation with the rest receiving external fixation. Definitive internal fixation of both bones yields the best results in almost all series. Nailing of both bones is the optimal fixation when both fractures (femoral and tibial) are extra-articular. Plates are the ‘standard of care’ in cases with articular fractures. A combination of implants are required by 40% of floating knees. Associated ligamentous and meniscal lesions are common, but may be irrelevant in the case of an intra-articular fracture which gives the worst prognosis for this type of lesion. Cite this article: Muñoz Vives K, Bel J-C, Capel Agundez A, Chana Rodríguez F, Palomo Traver J, Schultz-Larsen M, Tosounidis, T. The floating knee. EFORT Open Rev 2016;1:375-382. DOI: 10.1302/2058-5241.1.000042. PMID:28461916

  11. Stress fracture of the second proximal phalanx of the foot in teenage athletes: Unrecognized location of stress fracture.

    PubMed

    Yamaguchi, Satoshi; Taketomi, Shuji; Funakoshi, Yusei; Tsuchiya, Kan; Akagi, Ryuichiro; Kimura, Seiji; Sadamasu, Aya; Ohtori, Seiji

    2017-10-01

    Adolescent athletes are a high-risk population for stress fractures. We report four cases of stress fractures of the second proximal phalanx, which had not been previously diagnosed as the location of the stress fracture of the foot, in teenage athletes. All fractures were on the plantar side of the proximal phalangeal base, and the oblique images of the plain radiograph clearly depicted the fractures. Notably, three out of the four patients had histories of stress fracture of other locations. While three athletes with acute cases were able to make an early return to play with simple conservative management, the chronic case required surgical treatment for this rare injury. Although a rare injury, it is important that clinicians be aware of this type of stress fracture, as a timely diagnosis can avoid the need for surgical treatment and allow an early return to play.

  12. Management of proximal humeral fractures in the nineteenth century: an historical review of preradiographic sources.

    PubMed

    Brorson, Stig

    2011-04-01

    The diagnosis and treatment of fractures of the proximal humerus have troubled patients and medical practitioners since antiquity. Preradiographic diagnosis relied on surface anatomy, pain localization, crepitus, and impaired function. During the nineteenth century, a more thorough understanding of the pathoanatomy and pathophysiology of proximal humeral fractures was obtained, and new methods of reduction and bandaging were developed. I reviewed nineteenth-century principles of (1) diagnosis, (2) classification, (3) reduction, (4) bandaging, and (5) concepts of displacement in fractures of the proximal humerus. A narrative review of nineteenth-century surgical texts is presented. Sources were identified by searching bibliographic databases, orthopaedic sourcebooks, textbooks in medical history, and a subsequent hand search. Substantial progress in understanding fractures of the proximal humerus is found in nineteenth-century textbooks. A rational approach to understanding fractures of the proximal humerus was made possible by an appreciation of the underlying functional anatomy and subsequent pathoanatomy. Thus, new principles of diagnosis, pathoanatomic classifications, modified methods of reduction, functional bandaging, and advanced concepts of displacement were proposed, challenging the classic management adhered to for more than 2000 years. The principles for modern pathoanatomic and pathophysiologic understanding of proximal humeral fractures and the principles for classification, nonsurgical treatment, and bandaging were established in the preradiographic era.

  13. Peri-prosthetic fractures around tumor endoprostheses: a retrospective analysis of eighteen cases.

    PubMed

    Barut, Nicolas; Anract, Philippe; Babinet, Antoine; Biau, David

    2015-09-01

    Tumour hip and knee endoprostheses have become the mainstay for reconstruction of patients with bone tumours. Fixation into host bone has improved over time. However, some patients present with a peri-prosthetic fracture over follow-up. The objective of this study was to analyse the mode of presentation and survival of implant after a peri-prosthetic fracture around a tumour endoprosthesis. Eighteen peri-prosthetic fractures (17 patients) were included. All patients were treated at a tertiary care center. There were 11 (65%) women; the median age at the time of fracture was 38 years old. All implants were cemented and all knee endoprostheses were fixed-hinge. Twelve (67%) fractures occurred after femoral resection and six (33%) fractures after proximal tibial resection. There were three femoral neck fractures (UCS C), three femoral shaft type C fractures, two femoral shaft type B1, one tibial shaft type B2, three tibial shaft type C, three ankle fractures (UCS C) and three patella fractures (UCS F). Two fractures were treated conservatively and 16 were operated on. Only one patient had the implant revised. There were eight (44%) failures over follow-up; none of the conservative treatment failed. The cumulative probability of failure for any reason was 27% (8-52) and 55% (22-79) at five and ten years, respectively. Peri-prosthetic fractures around massive endoprostheses are different from that of standard implants. There are more type C fractures; internal fixation is an attractive option at the time of presentation but the risk of revision over follow-up is high and patients should be informed accordingly.

  14. Treatment of proximal humerus fractures with locking plates: a systematic review.

    PubMed

    Thanasas, Christos; Kontakis, George; Angoules, Antonios; Limb, David; Giannoudis, Peter

    2009-01-01

    Locking plates with special configuration for the anatomic region of the proximal humerus have been introduced recently to address the difficulties of stabilizing proximal humeral fractures. The purpose of this study was to carry out a systematic review of the literature on the efficacy and early to medium term functional results of locking plates for stabilization of proximal humeral fractures. Using the PubMed database, a systematic review of the English and German literature was carried out in order to assess the efficacy and complications related to the use of these plates and the patients' functional outcome, using the key words "locking plates proximal humeral fractures," "angular stability plates proximal humeral fractures," "PHILOS plate," and "LPHP plate." Our criteria for eligibility were clinical studies with more than ten cases followed-up, adult patients, and adequate data provided at least in terms of implant related complications. Articles written in English and German language were included. Exclusion criteria were: studies dealing exclusively with 2-part fractures (since this category has a more favorable outcome); experimental studies; case reports; and, literature other than English or German. Each one of the articles was evaluated for quality of the study using the Structured Effectiveness Quality Evaluation Scale (SEQES). Twelve studies including 791 patients met the inclusion criteria. Patients in these studies continued to improve up to one year, achieving a mean Constant score of 74.3. The incidence of the reported complications was: avascular necrosis 7.9%, screw cut-out 11.6% and re-operation rate 13.7%. The high incidence of cut-out may be secondary to the rigidity of the implant in combination with medial inadequate support, in cases compromised by severe underlying osteoporotic bone. Definition of indications for the use of locking plates and attention on technical aspects of applying them would help optimization of the results

  15. Comparison of two-staged ORIF and limited internal fixation with external fixator for closed tibial plafond fractures.

    PubMed

    Wang, Cheng; Li, Ying; Huang, Lei; Wang, Manyi

    2010-10-01

    To compare the results of two-staged open reduction and internal fixation (ORIF) and limited internal fixation with external fixator (LIFEF) for closed tibial plafond fractures. From January 2005 to June 2007, 56 patients with closed type B3 or C Pilon fractures were randomly allocated into groups I and II. Two-staged ORIF was performed in group I and LIFEF in group II. The outcome measures included bone union, nonunion, malunion, pin-tract infection, wound infection, osteomyelitis, ankle joint function, etc. These postoperative data were analyzed with Statistical Package for Social Sciences (SPSS) 13.0. Incidence of superficial soft tissue infection (involved in wound infection or pin-tract infection) in group I was lower than that in group II (P < 0.05), with significant difference. Group I has significantly less radiation exposure (P < 0.001). Group II had higher rates of malunion, delayed union, and arthritis symptoms, with no statistical significance. Both groups resulted similar ankle joint function. Logistic regression analysis indicated that smoking and fracture pattern were the two factors significantly influencing the final outcomes. In the treatment of closed tibial plafond fractures, both two-staged ORIF and LIFEF offer similar results. Patients undergo LIFEF carry significantly greater radiation exposure and higher superficial soft tissue infection rate (usually occurs on pin tract and does not affect the final outcomes).

  16. Functional outcome of tibial fracture with acute compartment syndrome and correlation to deep posterior compartment pressure.

    PubMed

    Goyal, Saumitra; Naik, Monappa A; Tripathy, Sujit Kumar; Rao, Sharath K

    2017-05-18

    To measure single baseline deep posterior compartment pressure in tibial fracture complicated by acute compartment syndrome (ACS) and to correlate it with functional outcome. Thirty-two tibial fractures with ACS were evaluated clinically and the deep posterior compartment pressure was measured. Urgent fasciotomy was needed in 30 patients. Definite surgical fixation was performed either primarily or once fasciotomy wound was healthy. The patients were followed up at 3 mo, 6 mo and one year. At one year, the functional outcome [lower extremity functional scale (LEFS)] and complications were assessed. Three limbs were amputated. In remaining 29 patients, the average times for clinical and radiological union were 25.2 ± 10.9 wk (10 to 54 wk) and 23.8 ± 9.2 wk (12 to 52 wk) respectively. Nine patients had delayed union and 2 had nonunion who needed bone grafting to augment healing. Most common complaint at follow up was ankle stiffness (76%) that caused difficulty in walking, running and squatting. Of 21 patients who had paralysis at diagnosis, 13 (62%) did not recover and additional five patients developed paralysis at follow-up. On LEFS evaluation, there were 14 patients (48.3%) with severe disability, 10 patients (34.5%) with moderate disability and 5 patients (17.2%) with minimal disability. The mean pressures in patients with minimal disability, moderate disability and severe disability were 37.8, 48.4 and 58.79 mmHg respectively ( P < 0.001). ACS in tibial fractures causes severe functional disability in majority of patients. These patients are prone for delayed union and nonunion; however, long term disability is mainly because of severe soft tissue contracture. Intra-compartmental pressure (ICP) correlates with functional disability; patients with relatively high ICP are prone for poor functional outcome.

  17. Displaced Proximal Humerus Fractures: is a Sling as Good as a Plate?

    PubMed

    Steinhaus, Michael E; Dare, David M; Gulotta, Lawrence V

    2016-10-01

    The treatment of displaced proximal humerus fractures is challenging and complex, as its success is predicated on multiple factors. While it is clear that a majority of proximal humerus fractures may be treated nonoperatively, it is less clear which patients benefit from surgical management. The PROFHER trial, a randomized controlled study, used patient-reported outcomes to compare surgical to nonsurgical management of displaced proximal humerus fractures. The purpose of this review is to highlight the strengths and weaknesses of the PROFHER trial and to assess the validity of its conclusion in the context of existing literature. The authors found no difference in the Oxford Shoulder Score (OSS) between the surgical and nonsurgical groups. Additionally, no difference was found between groups in any of the secondary outcomes, which included the Short-Form 12 (SF-12) health survey, surgical and fracture-related complications, additional surgery or therapy, inpatient medical complications, and mortality. They concluded that the recent increase in surgical management of proximal humerus fractures is perhaps unwarranted. While the randomization was successful and the pragmatic design may enable greater generalizability, this study possesses numerous flaws inherent in such an ambitious endeavor, including an inability to identify specific factors which explain the lack of superiority of surgical management. Despite its weaknesses, this study is a valuable datapoint which encourages surgeons to reexamine their surgical indications for this injury.

  18. The outcome of unstable proximal femoral fracture treated with reverse LISS plates.

    PubMed

    Lin, Shih-Jie; Huang, Kuo-Chin; Chuang, Po-Yao; Lee, Chien-Yin; Huang, Tsan-Wen; Lee, Mel S; Hsu, Robert Wen-Wei

    2016-10-01

    The Russel-Taylor type 2B fractures compromised the trochanteric region and medial buttress of proximal femur. This fracture pattern limits the choice of implants and raises the risk of adverse outcomes. We aimed to (i) determine the outcome of Russel-Taylor type 2B fractures treated using reverse less invasive stabilization system plates (LISS-DF) and to (ii) learn what factors affected outcomes after osteosynthesis with reverse LISS plates. A retrospective study SETTING: The study was conducted at a Level III trauma center in Taiwan. Twenty-five consecutive patients presenting with a Russel-Taylor type 2B fracture were enrolled. All cases were treated with reverse LISS plates. A Modified Radiographic Union Scale for Femur (RUSF), Radiographic parameters, functional scores, and complications were assessed. Union occurred in 21 cases at an average of 18.8 weeks. The average immediate postoperative neck-shaft angle was 130° (range: 122-135°) compared with 139° (range: 135-141°, p=0.05) on the contralateral side. Two cases had complications of proximal screws cutting out and two cases had broken implants. Finally, all 4 cases required repeated surgeries (16%). Malunion occurred in 4 patients and early mechanical failure (proximal screws cut out) occurred in 2. There was a significant difference in the purchase index of the proximal screws between cases with redisplacement and those without (26.4mm and 98.6mm, p=0.01). The use of reverse LISS plate appeared to be an alternative procedure for the specific pattern in the present study. We recommend using this reverse locking plate to treat unstable proximal femoral fractures with meticulous techniques of placing plates. Adequate purchase of the proximal locking screws might decrease the risks of complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. A Prospective Randomized Study on Operative Treatment for Simple Distal Tibial Fractures-Minimally Invasive Plate Osteosynthesis Versus Minimal Open Reduction and Internal Fixation.

    PubMed

    Kim, Ji Wan; Kim, Hyun Uk; Oh, Chang-Wug; Kim, Joon-Woo; Park, Ki Chul

    2018-01-01

    To compare the radiologic and clinical results of minimally invasive plate osteosynthesis (MIPO) and minimal open reduction and internal fixation (ORIF) for simple distal tibial fractures. Randomized prospective study. Three level 1 trauma centers. Fifty-eight patients with simple and distal tibial fractures were randomized into a MIPO group (treatment with MIPO; n = 29) or a minimal group (treatment with minimal ORIF; n = 29). These numbers were designed to define the rate of soft tissue complication; therefore, validation of superiority in union time or determination of differences in rates of delayed union was limited in this study. Simple distal tibial fractures treated with MIPO or minimal ORIF. The clinical outcome measurements included operative time, radiation exposure time, and soft tissue complications. To evaluate a patient's function, the American Orthopedic Foot and Ankle Society ankle score (AOFAS) was used. Radiologic measurements included fracture alignment, delayed union, and union time. All patients acquired bone union without any secondary intervention. The mean union time was 17.4 weeks and 16.3 weeks in the MIPO and minimal groups, respectively. There was 1 case of delayed union and 1 case of superficial infection in each group. The radiation exposure time was shorter in the minimal group than in the MIPO group. Coronal angulation showed a difference between both groups. The American Orthopedic Foot and Ankle Society ankle scores were 86.0 and 86.7 in the MIPO and minimal groups, respectively. Minimal ORIF resulted in similar outcomes, with no increased rate of soft tissue problems compared to MIPO. Both MIPO and minimal ORIF have high union rates and good functional outcomes for simple distal tibial fractures. Minimal ORIF did not result in increased rates of infection and wound dehiscence. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  20. Evaluation of Fracture and Osteotomy Union in the Setting of Osteogenesis Imperfecta: Reliability of the Modified Radiographic Union Score for Tibial Fractures (RUST).

    PubMed

    Franzone, Jeanne M; Finkelstein, Mark S; Rogers, Kenneth J; Kruse, Richard W

    2017-09-08

    Evaluation of the union of osteotomies and fractures in patients with osteogenesis imperfecta (OI) is a critical component of patient care. Studies of the OI patient population have so far used varied criteria to evaluate bony union. The radiographic union score for tibial fractures (RUST), which was subsequently revised to the modified RUST, is an objective standardized method of evaluating fracture healing. We sought to evaluate the reliability of the modified RUST in the setting of the tibias of patients with OI. Tibial radiographs of 30 patients with OI fractures, or osteotomies were scored by 3 observers on 2 separate occasions. Each of the 4 cortices was given a score (1=no callus, 2=callus present, 3=bridging callus, and 4=remodeled, fracture not visible) and the modified RUST is the sum of these scores (range, 4 to 16). The interobserver and intraobserver reliabilities were evaluated using intraclass coefficients (ICC) with 95% confidence intervals. The ICC representing the interobserver reliability for the first iteration of scores was 0.926 (0.864 to 0.962) and for the second series was 0.915 (0.845 to 0.957). The ICCs representing the intraobserver reliability for each of the 3 reviewers for the measurements in series 1 and 2 were 0.860 (0.707 to 0.934), 0.994 (0.986 to 0.997), and 0.974 (0.946 to 0.988). The modified RUST has excellent interobserver and intraobserver reliability in the setting of OI despite challenges related to the poor quality of the bone and its dysplastic nature. The application and routine use of the modified RUST in the OI population will help standardize our evaluation of osteotomy and fracture healing. Level III-retrospective study of nonconsecutive patients.

  1. Recurrent Proximal Femur Fractures in a Teenager With Osteogenesis Imperfecta on Continuous Bisphosphonate Therapy: Are We Overtreating?

    PubMed

    Vasanwala, Rashida F; Sanghrajka, Anish; Bishop, Nicholas J; Högler, Wolfgang

    2016-07-01

    Long-term bisphosphonate (BP) therapy in adults with osteoporosis is associated with atypical femoral fractures, caused by increased material bone density and prolonged suppression of bone remodeling which may reduce fracture toughness. In children with osteogenesis imperfecta (OI), long-term intravenous BP therapy improves bone structure and mass without further increasing the already hypermineralized bone matrix, and is generally regarded as safe. Here we report a teenage girl with OI type IV, who was started on cyclical intravenous pamidronate therapy at age 6 years because of recurrent fractures. Transiliac bone biopsy revealed classical structural features of OI but unusually low bone resorption surfaces. She made substantial improvements in functional ability, bone mass, and fracture rate. However, after 5 years of pamidronate therapy she started to develop recurrent, bilateral, nontraumatic, and proximal femur fractures, which satisfied the case definition for atypical femur fractures. Some fractures were preceded by periosteal reactions and prodromal pain. Pamidronate was discontinued after 7 years of therapy, following which she sustained two further nontraumatic femur fractures, and continued to show delayed tibial osteotomy healing. Despite rodding surgery, and very much in contrast to her affected, untreated, and normally mobile mother, she remains wheelchair-dependent. The case of this girl raises questions about the long-term safety of BP therapy in some children, in particular about the risk of oversuppressed bone remodeling with the potential for microcrack accumulation, delayed healing, and increased stiffness. The principal concern is whether there is point at which benefit from BP therapy could turn into harm, where fracture risk increases again. This case should stimulate debate whether current adult atypical femoral fracture guidance should apply to children, and whether low-frequency, low-dose cyclical, intermittent, or oral treatment

  2. Extra-articular osteotomy for malunited unicondylar fractures of the proximal phalanx.

    PubMed

    Harness, Neil G; Chen, Alvin; Jupiter, Jesse B

    2005-05-01

    To evaluate an extra-articular osteotomy rather than an intra-articular osteotomy in the treatment of malunited unicondylar fractures of the proximal phalanx. An extra-articular osteotomy was used to correct the deformity resulting from a malunion of a unicondylar fracture of the proximal phalanx in 5 patients. A closing wedge osteotomy that was stabilized with tension band fixation accomplished realignment of the joint. Each patient was evaluated at a minimum of 1 year after surgery for radiographic healing, correction of angulation, digital motion, postoperative complications, current level of pain with motion, and overall satisfaction with the procedure. All of the osteotomies healed by 10 to 12 weeks after surgery with an average angular correction from 25 degrees to 1 degrees . The average proximal interphalangeal joint motion improved to 86 degrees from the preoperative average of 40 degrees , whereas the average total digital motion improved from 154 degrees before surgery to 204 degrees at follow-up evaluation. This method of extra-articular osteotomy for malunited unicondylar fractures of the proximal phalanx is highly reproducible, avoids the risks of intra-articular surgery, and leads to a predictable outcome.

  3. A qualitative approach to recovery after open tibial fracture: the road to a novel, patient-derived recovery scale.

    PubMed

    Trickett, R W; Mudge, Elizabeth; Price, Patricia; Pallister, Ian

    2012-07-01

    The aim of this study was to describe how patients perceive their recovery following open tibial fractures using a qualitative approach. Following the appropriate ethical approval, adult patients with a diagnosis of open tibial fracture were recruited after completion of their surgical treatment and discharge from Morriston Hospital, a centre with orthoplastic surgical care. A purposive sampling method was employed to ensure that a range of injuries as well as clinical outcomes were included. All patients took part in an in-depth semi-structured interview, exploring aspects of their injury, treatment, rehabilitation and psychosocial and financial situations. Interviews were completed with two interviewers present and were recorded for verbatim transcription. Interview transcripts were analysed to identify items important to patients during their recovery. Nine patients with a mean injury to interview interval of 2.3 years were interviewed. A total of 538 items were identified and subsequently mapped onto 18 categories: pain; mobility; flexibility; temperature (effects on symptoms); fear; appearance; sleep; diet/weight; employment; social; finance; impact on others; self-care; recovery (patient perceptions of recovery); frustration; goal setting (by patients and health-care providers); and adaptation (both physical and mental). There is a wide range of factors that our cohort found important during their recovery from open tibial fracture. Despite being considered as 'healed' by the medical staff, patients did not report a corresponding full recovery and return to pre-injury normality. The categories identified will enable the development of a patient-reported recovery scale to be used in lower-limb trauma. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Comparison of volumetric bone mineral density in the tibial region of interest for ACL reconstruction.

    PubMed

    Klein, Scott A; Nyland, John; Caborn, David N M; Kocabey, Yavuz; Nawab, Akbar

    2005-12-01

    Adequate tibial bone mineral density (BMD) is essential to soft tissue graft fixation during anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to compare volumetric bone plug density measurements at the tibial region of interest for ACL reconstruction using a standardized immersion technique and Archimedes' principle. Cancellous bone cores were harvested from the proximal, middle, and distal metaphyseal regions of the lateral tibia and from the standard tibial tunnel location used for ACL reconstruction of 18 cadaveric specimens. Proximal tibial cores displayed 32.6% greater BMD than middle tibial cores and 31.8% greater BMD than distal tibial cores, but did not differ from the BMD of the tibial tunnel cores. Correlational analysis confirmed that the cancellous BMD in the tibial tunnel related to the cancellous BMD of the proximal and distal lateral tibial metaphysis. In conjunction with its adjacent cortical bone, the cancellous BMD of the region used for standard tibial tunnel placement provides an effective foundation for ACL graft fixation. In tibia with poor BMD, bicortical fixation that incorporates cortical bone from the distal tibial tunnel region is recommended.

  5. Fat embolism syndrome in an adolescent before surgical treatment of an isolated closed tibial shaft fracture.

    PubMed

    Nawaf, Cayce B; Kelly, Derek M; Warner, William C; Beaty, James H; Rhodes, Leslie; Sawyer, Jeffrey R

    2012-12-01

    Fat embolism syndrome (FES) occurs most commonly in adults with high-energy trauma, especially fractures of the long-bones and pelvis. Because of unique age-related physiologic differences in the immature skeleton, as well as differences in fracture management in pediatric patients, FES is rare in children. To our knowledge, this is the first case report of FES occurring before surgical fixation of a closed tibial shaft fracture in an adolescent. A 16-year-old, 109 kg, Caucasian adolescent boy developed FES after closed diaphyseal fractures of the distal tibia and fibula, showing signs of respiratory distress and mental status changes. The FES resolved with supportive respiratory care and intramedullary nailing of the fracture was done without further respiratory compromise. FES is uncommon in children and adolescents. A high index of suspicion is required to make the diagnosis promptly and institute appropriate treatment. Intramedullary nailing of a long-bone fracture can be done safely and successfully after resolution of the FES.

  6. [Revision of Schatzker type Ⅵ tibial plateau fracture failure focus on the recovery of lower limb alignment].

    PubMed

    Cong, R J; Liu, J F; Jiang, Y; Dilixiati, Duolikun; Hou, X D; Zheng, L P

    2018-03-01

    Objective: To explore the influence of the lower extremity abnormal alignment and the joint surface, and to explore the surgical skills. Methods: Twenty-two cases of tibial plateau Schatzker Ⅵ fracture internal fixation failure revision from January 2012 to January 2017 in Department of Orthopedics, Shanghai 10(th) Hospital.One year follow-up after initial surgery to make sure of failure.Three-dimensional CT scan, radiography, infection index, gait analysis, knee joint ROM, femur tibia angle, tibial plateau tibial shaft angle and posterior slope if tibial plateau were observed. The medial approach and bi-planer osteotoma were used.Autogenous iliac bone graft, postoperative fast recovery channel were used.Follow-up point included preoperative and postoperative 7 days, 6 weeks, 3 months, and 6 months.Obvervational index included double lower limbs radiography, knee society score(KSS), complications such as infection, skin necrosis, joint main passive activity, double lower limbs alignment the last follow-up SF-36 scale.Rate was compared by χ(2) test, measurement data using paired sample t test.Correlation was analyzed by Pearson correlation regression testing. Results: Twenty-two patients received follow-up.KSS, more than 21 cases were benign, with good gait.One case was poor, with claudication gait.Not skin necrosis, no deep infection cases, 1 case get blisters 2 days postoperatively, and disappear after 5 days with detumescence and cold therapy.Whether restoring force line affect the KSS significantly(χ(2)=22.000, P =0.000). Knee joint ROM, SF-36 score, KSS and lower limb alignment were improved significantly. In different individual the articular surface and anatomical angle recovered greatly but the posterior slope angle was quite difference which has no correlation with KSS and SF-36 scale( P >0.01). Conclusions: Revision of Schatzker type Ⅵ tibial plateau fracture failure should focus on the recovery of lower limb alignment.moderate overcorrect bone

  7. Anaesthesia for proximal femoral fracture in the UK: first report from the NHS Hip Fracture Anaesthesia Network.

    PubMed

    White, S M; Griffiths, R; Holloway, J; Shannon, A

    2010-03-01

    The aim of this audit was to investigate process, personnel and anaesthetic factors in relation to mortality among patients with proximal femoral fractures. A questionnaire was used to record standardised data about 1195 patients with proximal femoral fracture admitted to 22 hospitals contributing to the Hip Fracture Anaesthesia Network over a 2-month winter period. Patients were demographically similar between hospitals (mean age 81 years, 73% female, median ASA grade 3). However, there was wide variation in time from admission to operation (24-108 h) and 30-day postoperative mortality (2-25%). Fifty percent of hospitals had a mean admission to operation time < 48 h. Forty-two percent of operations were delayed: 51% for organisational; 44% for medical; and 4% for 'anaesthetic' reasons. Regional anaesthesia was administered to 49% of patients (by hospital, range = 0-82%), 51% received general anaesthesia and 19% of patients received peripheral nerve blockade. Consultants administered 61% of anaesthetics (17-100%). Wide national variations in current management of patients sustaining proximal femoral fracture reflect a lack of research evidence on which to base best practice guidance. Collaborative audits such as this provide a robust method of collecting such evidence.

  8. Treatment of Lateral Tibial Condylar Fractures Using Bioactive, Bioresorbable Forged Composites of Raw Particulate Unsintered Hydroxyapatite/Poly-L-Lactide Screws.

    PubMed

    Kuroyanagi, Gen; Yoshihara, Hiroyuki; Yamamoto, Naohiro; Suzuki, Hiroyuki; Yamada, Kunio; Yoshida, Yukio; Otsuka, Takanobu; Takada, Naoya

    2018-05-01

    Forged composites of raw particulate unsintered hydroxyapatite/poly-L-lactide (F-u-HA/PLLA) devices possess high mechanical strength, bioactivity, and radio-opacity. The aim of this study was to assess the efficacy of F-u-HA/PLLA screws in the treatment of lateral tibial condylar fractures. From January 2005 to December 2010, a total of 7 patients with displaced closed lateral tibial condylar fractures (Schatzker type II) were treated using F-u-HA/PLLA screws. Open reduction and internal fixation was performed using 2 or 3 F-u-HA/PLLA screws. After surgery, weight bearing was not allowed for 6 weeks. Range of motion exercise was initiated after removal of the plaster splint. Radiographs were evaluated for fracture healing, joint depression, and the radioopacity of F-u-HA/PLLA screws. Clinical outcomes and postoperative complications were also assessed. Average follow-up was 44 months. All fractures were successfully healed. Average values for joint depression were 4.7 mm (range, 2-9 mm) preoperatively, 0.4 mm (range, 0-1 mm) postoperatively, and 0.4 mm (range, 0-1 mm) at final follow-up. Whole shadows of F-u-HA/PLLA screws were observed during the follow-up period. Breakage of screws, osteolysis, and a radiolucent zone around the screws were not observed at final follow-up. Average knee flexion and extension were 134° (range, 110° to 150°) and -1° (range, -10° to 0°), respectively. No patient had wound infection, late aseptic tissue response, or foreign body reaction postoperatively. None of the patients reported pain at final follow-up. These results suggest that F-u-HA/PLLA screws could be an alternative option for the treatment of lateral tibial condylar fractures. [Orthopedics. 2018; 41(3):e365-e368.]. Copyright 2018, SLACK Incorporated.

  9. Biomechanical Evaluation of Standard Versus Extended Proximal Fixation Olecranon Plates for Fixation of Olecranon Fractures.

    PubMed

    Boden, Allison L; Daly, Charles A; Dalwadi, Poonam P; Boden, Stephanie A; Hutton, William C; Muppavarapu, Raghuveer C; Gottschalk, Michael B

    2018-01-01

    Small olecranon fractures present a significant challenge for fixation, which has resulted in development of plates with proximal extension. Olecranon-specific plates with proximal extensions are widely thought to offer superior fixation of small proximal fragments but have distinct disadvantages: larger dissection, increased hardware prominence, and the increased possibility of impingement. Previous biomechanical studies of olecranon fracture fixation have compared methods of fracture fixation, but to date there have been no studies defining olecranon plate fixation strength for standard versus extended olecranon plates. The purpose of this study is to evaluate the biomechanical utility of the extended plate for treatment of olecranon fractures. Sixteen matched pairs of fresh-frozen human cadaveric elbows were used. Of the 16, 8 matched pairs received a transverse osteotomy including 25% and 8 including 50% of the articular surface on the proximal fragment. One elbow from each pair was randomly assigned to a standard-length plate, and the other elbow in the pair received the extended-length plate, for fixation of the fracture. The ulnae were cyclically loaded and subsequently loaded to failure, with ultimate load, number of cycles, and gap formation recorded. There was no statistically significant difference between the standard and extended fixation plates in simple transverse fractures at either 25% or 50% from the proximal most portion of the articular surface of the olecranon. Standard fixation plates are sufficient for the fixation of small transverse fractures, but caution should be utilized particularly with comminution and nontransverse fracture patterns.

  10. Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?

    PubMed

    Mui, Leonora W; Engelsohn, Eliyahu; Umans, Hilary

    2007-02-01

    (1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular depression was significantly greater in patients with meniscal injury compared with those without meniscal injury, ROC analysis demonstrated no clear threshold for gap or depression that yielded a combination of high sensitivity and specificity. In the acute setting, CT offers high sensitivity and specificity for depicting osseous avulsions, as well as high negative predictive value for excluding ligament injury. However, MRI remains necessary for the preoperative detection of meniscal injury.

  11. Biomechanical outcome of proximal femoral nail antirotation is superior to proximal femoral locking compression plate for reverse oblique intertrochanteric fractures: a biomechanical study of intertrochanteric fractures.

    PubMed

    Ma, Jian-Xiong; Wang, Jie; Xu, Wei-Guo; Yu, Jing-Tao; Yang, Yang; Ma, Xin-Long

    2015-01-01

    Reverse obliquity intertrochanteric fractures are a challenge for orthopedic surgeons. The optimal internal fixation for repairing this type of unstable intertrochanteric fractures remains controversial. This study aimed to compare the biomechanical properties in axial load and cyclical axial load of proximal femoral nail antirotation (PFNA) and proximal femoral locking compression plate (PFLCP) for fixation of reverse obliquity intertrochanteric fractures. Sixteen embalmed cadaver femurs were sawed to simulate reverse obliquity intertrochanteric fracture and instrumented with PFNA or PFLCP. Axial loads and axial cyclic loads were applied to the femoral head by an Instron tester. If the implant-femur constructs did not fail, axial failure load was added to the remaining implant-femur constructs. Mean axial stiffness for PFNA was 21.10% greater than that of PFLCP. Cyclic axial loading caused significantly less (p=0.022) mean irreversible deformation in PFNA (3.43 mm) than in PFLCP (4.34 mm). Significantly less (p=0.002) mean total deformation was detected in PFNA (6.16 mm) than in PFLCP (8.67 mm). For fixing reverse obliquity intertrochanteric fractures, PFNA is superior to PFLCP under axial load.

  12. Treatment for proximal humeral fractures with percutaneous plating: our first results.

    PubMed

    Imarisio, D; Trecci, A; Sabatini, L; Scagnelli, R

    2013-06-01

    Proximal humeral fractures are common lesions; there is no generally accepted strategy about the treatment for displaced and unstable two- to four-part fractures. We have nowadays many different surgical solutions, ranging from percutaneous pinning to shoulder arthroplasty. Percutaneous plating can be a good solution to treat some of these fractures using a minimally invasive technique and performing stable fixation that can allow early mobilization. Purpose of this paper is to evaluate the results of our first cases of percutaneous plating in proximal humeral fractures in order to assess the theoretical advantages and the incidence of possible complications. From June 2009 to February 2012, we treated 29 proximal humeral fractures with a percutaneous plating (NCB-PH plate) through an anterolateral deltoid split. For each patient, we evaluated the clinical outcome according to Constant score and the radiographic results, paying attention to fracture healing, loss of reduction, hardware complications, and head necrosis. The clinical evaluation gave a mean Constant score value of 79 points. Comparing each value to the unaffected shoulder, we could find these results: 7 excellent, 10 good, 8 fair, and 4 poor. No axillary nerve lesions were clinically detected. The radiographic evaluation showed a complete bone healing in all cases within the first 3 months. No head necrosis was detected, as well as screws loosening. In two cases, the X-ray at 2 months revealed a little loss of reduction in varus. Two patients had an anterior pain; in one of these two cases, the plate was removed. In our series, we had no cases of head necrosis, screws cutout, fracture collapse, hardware mobilization, and we think this could be the real advantage of the percutaneous technique compared to the open one, thanks to the reduced biological damage. We had some poor results, related more to patient's age than to other factors. The safety of the technique for the axillary nerve is

  13. A Meta-Analysis for Postoperative Complications in Tibial Plafond Fracture: Open Reduction and Internal Fixation Versus Limited Internal Fixation Combined With External Fixator.

    PubMed

    Wang, Dong; Xiang, Jian-Ping; Chen, Xiao-Hu; Zhu, Qing-Tang

    2015-01-01

    The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Surgery for pathological proximal femoral fractures, excluding femoral head and neck fractures: resection vs. stabilisation.

    PubMed

    Zacherl, Max; Gruber, Gerald; Glehr, Mathias; Ofner-Kopeinig, Petra; Radl, Roman; Greitbauer, Manfred; Vecsei, Vilmos; Windhager, Reinhard

    2011-10-01

    Pathological femoral head and neck fractures are commonly treated by arthroplasty. Treatment options for the trochanteric region or below are not clearly defined. The purpose of this retrospective, comparative, double-centre study was to analyse survival and influences on outcome according to the surgical technique used to treat pathological proximal femoral fractures, excluding fractures of the femoral head and neck. Fifty-nine patients with 64 fractures were operated up on between 1998 and 2004 in two tertiary referral centres and divided into two groups. One group (S, n = 33) consisted of patients who underwent intramedullary nailing alone, and the other group (R, n = 31) consisted of patients treated by metastatic tissue resection and reconstruction by means of different implants. Median survival was 12.6 months with no difference between groups. Surgical complications were higher in the R group (n = 7) vs. the S group (n = 3), with no statistically significant difference. Patients with surgery-related complications had a higher survival rate (p = 0.049), as did patients with mechanical implant failure (p = 0.01). Survival scoring systems did not correlate with actual survival. Resection of metastases in patients with pathological fractures of the proximal femur, excluding femoral head and neck fractures, has no influence on survival. Patients with long postoperative survival prognosis are at risk of implant-related complications.

  15. [Treatment of proximal ulna and olecranon fractures by reconstruction plate combined with tension band wiring].

    PubMed

    Teng, Lin; Zhong, Gang; Xiao, Cong; Liu, Gang; Xiang, Zhou; Cen, Shiqiang; Huang, Fuguo

    2011-01-01

    OBJECTIVE To review the efficacy of reconstruction plate combined with tension band wiring for treating proximal ulna and olecranon fractures. Between November 2004 and September 2009, 10 patients with proximal ulna and olecranon fractures were treated by reconstruction plate combined with tension band wiring. There were 6 males and 4 females with an average age of 45.3 years (range, 21-75 years). Five fractures were caused by traffic accident, 2 by falling from height, 2 by tumbling, and 1 by a machine strangulation. The locations were the left side and the right side in 5 cases respectively. One case was open fracture (Gustilo II) and the other 9 were closed fractures. Olecranon fractures included 4 cases of traverse fractures and 6 cases of comminuted fractures, and proximal ulna fractures included 6 cases of comminuted fractures and 4 cases of oblique fractures. The combined fractures included 6 radial head fractures, 4 coronoid process fractures, 2 proximal humerus fractures, and 3 scapula fractures; other injury included 1 elbow dislocation and 1 shoulder dislocation. Two patients had secondary operation; the other 8 patients received the primary operations and the time from injury to operation varied from 7 days to 20 days, with an average of 11 days. One case had infection at the incision 1 week after operation, and recovered after 2 months of antibiotics and debridement; incisions healed by first intention in other 9 patients. All patients were followed up 12-64 months (mean, 40.5 months). The X-ray films showed that fracture healing was achieved at 10-24 weeks (mean, 12 weeks). There was no ulnar nerve symptom in all cases. Heterotopic ossification occurred in 1 case at 2 months and stiffness of the elbow in 1 case at 3 months after operation; they were both cured after symptomatic treatment. Proximal migration of Kirschner wires was found in 1 case at 6 months after operation, whose implants were taken out at 9 months after the first operation because

  16. Fat embolism syndrome after nailing an isolated open tibial fracture in a stable patient: a case report.

    PubMed

    Aparicio, Gustavo; Soler, Isabel; López-Durán, Luis

    2014-04-14

    Fat embolism syndrome is a potentially fatal complication of long bone fractures. It is usually seen in the context of polytrauma or a femoral fracture. There are few reports of fat embolism syndrome occurring after isolated long bone fractures other than those of the femur. We describe a case of fat embolism syndrome in a 33-year-old Caucasian man. He was being seen for an isolated Gustilo's grade II open tibial fracture. He was deemed clinically stable, so we proceeded to treat the fracture with intramedullary reamed nailing. He developed fat embolism syndrome intraoperatively and was treated successfully. This case caused us to question the use of injury severity scoring for isolated long bone fractures. It suggests that parameters that have been described in the literature other than that the patient is apparently clinically stable should be used to establish the best time for nailing a long bone fracture, thereby improving patient safety.

  17. Fat embolism syndrome after nailing an isolated open tibial fracture in a stable patient: a case report

    PubMed Central

    2014-01-01

    Background Fat embolism syndrome is a potentially fatal complication of long bone fractures. It is usually seen in the context of polytrauma or a femoral fracture. There are few reports of fat embolism syndrome occurring after isolated long bone fractures other than those of the femur. Case presentation We describe a case of fat embolism syndrome in a 33-year-old Caucasian man. He was being seen for an isolated Gustilo’s grade II open tibial fracture. He was deemed clinically stable, so we proceeded to treat the fracture with intramedullary reamed nailing. He developed fat embolism syndrome intraoperatively and was treated successfully. Conclusion This case caused us to question the use of injury severity scoring for isolated long bone fractures. It suggests that parameters that have been described in the literature other than that the patient is apparently clinically stable should be used to establish the best time for nailing a long bone fracture, thereby improving patient safety. PMID:24731759

  18. Reverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures.

    PubMed

    Dumbre Patil, Sampat S; Karkamkar, Sachin S; Patil, Vaishali S Dumbre; Patil, Shailesh S; Ranaware, Abhijeet S

    2016-01-01

    When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described implants for revision surgery. There is no evidence in the literature to choose one implant over the other. We used the reverse distal femur locking compression plate (LCP) of the contralateral side in such cases undergoing revision surgery. This implant has multiple options of fixation in proximal femur and its curvature along the length matches the anterior bow of the femur. We aimed to evaluate the efficacy of this implant in salvage situations. Twenty patients of failed primary proximal femoral fractures who underwent revision surgery with reverse distal femoral locking plate from February 2009 to November 2012 were included in this retrospective study. There were 18 subtrochanteric fractures and two ipsilateral femoral neck and shaft fractures, which exhibited delayed union or nonunion. The study included 14 males and six females. The mean patient age was 43.6 years (range 22-65 years) and mean followup period was 52.1 months (range 27-72 months). Delayed union was considered when clinical and radiological signs of union failed to progress at the end of four months from initial surgery. All fractures exhibited union without any complications. Union was assessed clinically and radiologically. One case of ipsilateral femoral neck and shaft fracture required bone grafting at the second stage for delayed union of the femoral shaft fracture. Reverse distal femoral LCP of the contralateral side can be used as a salvage option for failed fixation of proximal femoral fractures exhibiting nonunion.

  19. [Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT].

    PubMed

    Kotsianos, D; Rock, C; Wirth, S; Linsenmaier, U; Brandl, R; Fischer, T; Euler, E; Mutschler, W; Pfeifer, K J; Reiser, M

    2002-01-01

    To analyze a prototype mobile C-arm 3D image amplifier in the detection and classification of experimental tibial condylar fractures with multiplanar reconstructions (MPR). Human knee specimens (n = 22) with tibial condylar fractures were examined with a prototype C-arm (ISO-C-3D, Siemens AG), plain films (CR) and spiral CT (CT). The motorized C-arm provides fluoroscopic images during a 190 degrees orbital rotation computing a 119 mm data cube. From these 3D data sets MP reconstructions were obtained. All images were evaluated by four independent readers for the detection and assessment of fracture lines. All fractures were classified according to the Müller AO classification. To confirm the results, the specimens were finally surgically dissected. 97 % of the tibial condylar fractures were easily seen and correctly classified according to the Müller AO classification on MP reconstruction of the ISO-C-3D. There is no significant difference between ISO-C and CT in detection and correct classification of fractures, but ISO-CD-3D is significant by better than CR. The evaluation of fractures with the ISO-C is better than with plain films alone and comparable to CT scans. The three-dimensional reconstruction of the ISO-C can provide important information which cannot be obtained from plain films. The ISO-C-3D may be useful in planning operative reconstructions and evaluating surgical results in orthopaedic surgery of the limbs.

  20. Comparison of plantar flexor musculotendinous stiffness, geometry, and architecture in male runners with and without a history of tibial stress fracture.

    PubMed

    Pamukoff, Derek N; Blackburn, J Troy

    2015-02-01

    Greater lower extremity joint stiffness may be related to the development of tibial stress fractures in runners. Musculotendinous stiffness is the largest contributor to joint stiffness, but it is unclear what factors contribute to musculotendinous stiffness. The purpose of this study was to compare plantar flexor musculotendinous stiffness, architecture, geometry, and Achilles tendon stiffness between male runners with and without a history of tibial stress fracture. Nineteen healthy runners (age = 21 ± 2.7 years; mass = 68.2 ± 9.3 kg; height = 177.3 ± 6.0 cm) and 19 runners with a history of tibial stress fracture (age = 21 ± 2.9 years; mass = 65.3 ± 6.0 kg; height = 177.2 ± 5.2 cm) were recruited from community running groups and the university's varsity and club cross-country teams. Plantar flexor musculotendinous stiffness was estimated from the damped frequency of oscillatory motion about the ankle follow perturbation. Ultrasound imaging was used to measure architecture and geometry of the medial gastrocnemius. Dependent variables were compared between groups via one-way ANOVAs. Previously injured runners had greater plantar flexor musculotendinous stiffness (P < .001), greater Achilles tendon stiffness (P = .004), and lesser Achilles tendon elongation (P = .003) during maximal isometric contraction compared with healthy runners. No differences were found in muscle thickness, pennation angle, or fascicle length.

  1. Asymmetry in gait pattern following tibial shaft fractures - a prospective one-year follow-up study of 49 patients.

    PubMed

    Larsen, Peter; Laessoe, Uffe; Rasmussen, Sten; Graven-Nielsen, Thomas; Berre Eriksen, Christian; Elsoe, Rasmus

    2017-01-01

    Despite the high number of studies evaluating the outcomes following tibial shaft fractures, the literature lacks studies including objective assessment of patients' recovery regarding gait pattern. The purpose of the present study was to evaluate whether gait patterns at 6 and 12 months post-operatively following intramedullary nailing of a tibial shaft fracture are different compared with a healthy reference population. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns at 6 and 12 months post-operatively measured with a 6-metre-long pressure-sensitive mat. The mat registers footprints and present gait speed, cadence as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. 49 patients were included with a mean age of 43.1 years (18-79 years). Forty-three patients completed the 12-month follow-up (88%). Gait speed and cadence were significantly increased between the 6- and 12-month follow-up (P<0.001). At 6-month follow-up, patients showed considerable asymmetry in the injured leg compared with the non-injured leg: single-support time 12.8% shorter, swing-time 12.8% longer, step-length 11.9% shorter, and rotation of the foot increased by 32.3%. At the 12-month follow-up, gait asymmetry become almost normalized compared to a healthy reference group. In patients treated by intramedullary nailing following a tibial shaft fracture, gait asymmetry accompanied with slower speed and cadence are common during the first 6 months and become normalized compared with a healthy reference population between 6 and 12 months post-operatively. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Treatment of proximal fifth metatarsal bone fractures in athletes.

    PubMed

    Japjec, M; Starešinić, M; Starjački, M; Žgaljardić, I; Štivičić, J; Šebečić, B

    2015-11-01

    Proximal fifth metatarsal (V MT) bone fractures are common injuries that are a major diagnostic and therapeutic challenge. Lawrence and Botte considered different treatment options and the possibility of recovery and divided these fractures into three different regions: tuberosity avulsion fractures (zone I), acute fractures of the metaphysis at the level of the intermetatarsal junction (zone II) and proximal diaphysis stress fracture (zone III). A total of 42 athletes with fracture of the V MT bone in zone II and III were treated in our institution during a 6-year period. All patients were offered surgical treatment, but nine patients refused surgery. Thus, the patients were divided into two groups: group 1 comprised 33 patients who underwent an intramedullary screw fixation operation under regional anaesthesia immediately after the fracture was diagnosed; group 2 contained the remaining nine patients who had refused surgery and received conservative therapy with non-weight-bearing short-leg casts or orthosis. Follow-up ranged from 6 to 24 months. All fractures healed in group 1: healing occurred within 8 weeks in 26 patients and was prolonged to 16 to 18 weeks in four patients. In group 2, fractures healed in four patients but did not heal in five patients even after 6 months. Four of the five patients in whom the fracture did not heal required subsequent osteosynthesis because they had constant problems that caused absence from sport. After the operation, their fractures healed in an average of 10 weeks. One patient decided not to undergo the operation due to the absence of subjective symptoms. Three patients in group 1 who started intensive training sustained a refracture and underwent re-operation in which osteosynthesis was performed with a stronger screw. The fractures then healed again. Treatment results were evaluated radiologically and clinically using the Modified Foot Score. Results in group 1 were significantly better than those in group 2 and there

  3. Influence of phototherapies on the outcome of complete tibial fractures grafted or not with MTA: Raman spectroscopic study on rabbits

    NASA Astrophysics Data System (ADS)

    Pinheiro, Antônio L. B.; Soares, Luiz G. P.; da Silva, Aline C. P.; Santos, Nicole R. S.; da Silva, Anna Paula L. T.; Neves, Bruno Luiz R. C.; Soares, Amanda P.; Silveira, Landulfo

    2018-02-01

    The aim of the present study was to assess, by means of Raman spectroscopy, the repair of complete surgical tibial fractures fixed with wire osteosynthesis or miniplates treated or not with infrared laser (λ780 nm) or infrared LED (λ850 +/- 10 nm) lights, 142.8 J/cm2 per treatment, associated or not to the use of mineral trioxide aggregate (MTA) cement. Surgical fractures were created on 36 rabbits and fixed with WO or miniplates and some groups were grafted with MTA. Irradiated groups received lights at every other day for 15 days and sacrifice occurred after 30 days. The results showed that only irradiation with either laser or LED influenced the peaks of phosphate ( 960 cm-1) and carbonated ( 1,070 cm-1) hydroxyapatite. Collagen peak (1,450 cm-1) was influenced by both the use of MTA and irradiation with either laser or LED. It is concluded that the use of either laser or LED phototherapy associated to MTA cement was efficacious on improving the repair of complete tibial fractures treated with wire osteosynthesis or miniplates.

  4. Role of Appositional Screw Fixation in Minimally Invasive Plate Osteosynthesis for Distal Tibial Fracture.

    PubMed

    Yang, Kyu-Hyun; Won, Yougun; Kang, Dong-Hyun; Oh, Jin-Cheol; Kim, Sung-Jun

    2015-09-01

    To determine the effect of interfragmentary appositional (gap-closing) screw fixation in minimally invasive plate osteosynthesis (MIPO) for distal tibial fractures on the clinical and radiologic results. Prospective nonrandomized study. Level I trauma center. Sixty patients who were diagnosed as distal metadiaphyseal oblique or spiral tibial fracture without displaced articular fragment. Thirty patients (group A) of the 60 patients were treated with MIPO without appositional screw fixation, and the other 30 (group B) were treated with the screw. Radiologic union, clinical union, clinical functional score [American Orthopaedic Foot and Ankle Society (AOFAS) score], and complications. The time for initial callus formation and radiologic union was significantly longer in group A than those in group B (76.8 vs. 58.0 days, P = 0.044; 409 vs. 258.7 days, P = 0.002, respectively). The rate of clinical union during 1 year was significantly higher in group B than in group A (P = 0.0063). Four nonunion patients in group A achieved bone union after placement of an additional bone graft. None of the patients in group B diagnosed with delayed union or nonunion (P < 0.001). None of the patients of both groups had malreduction, skin problems, or infection. Overall, the AOFAS score did not significantly differ between groups A and B (85.4 vs. 87.0, P = 0.43). The use of additional interfragmentary appositional screw fixation in distal tibia MIPO for the fixation of oblique or spiral fracture promoted callus formation and union rate compared with MIPO without appositional screw fixation. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  5. Incidence of infection after early intramedullary nailing of open tibial shaft fractures stabilized with pinless external fixators

    PubMed Central

    Kulshrestha, Vikas

    2008-01-01

    Background: A major drawback of conventional fixator system is the penetration of fixator pins into the medullary canal. The pins create a direct link between the medullary cavity and outer environment, leading to higher infection rates on conversion to intramedullary nailing. This disadvantage is overcome by the AO pinless fixator, in which the trocar points are clamped onto the outer cortex without penetrating it. This study was designed to evaluate the role of AO pinless fixators in primary stabilization of open diaphyseal tibial fractures that received staged treatment because of delayed presentation or poor general condition. We also analyzed the rate of infection on early conversion to intramedullary nail. Materials and Methods: This study is a retrospective review of 30 open diaphyseal fractures of tibia, which were managed with primary stabilization with pinless fixator and early exchange nailing. Outcome was evaluated in terms of fracture union and rate of residual infection. The data were compared with that available in the literature. Results: All the cases were followed up for a period of 2 years. The study includes Gustilo type 1 (n=10), 14 Gustilo type 2 (n=14), and type3 (n=6) cases. 6 cases (20%) had clamp site infection, 2 cases (6.7%) had deep infection, and in 28 cases (93%) the fracture healed and consolidated well. Conclusion: This study has highlighted the valuable role of pinless external fixator in the management of open tibial fractures in terms of safety and ease of application as well as the advantage of early conversion to intramedullary implant without the risk of deep infection. PMID:19753227

  6. Tibial Stress Injuries: Decisive Diagnosis and Treatment of "Shin Splints."

    ERIC Educational Resources Information Center

    Couture, Christopher J.; Karlson, Kristine A.

    2002-01-01

    Tibial stress injuries, commonly called shin splints, often result when bone remodeling processes adopt inadequately to repetitive stress. Physicians who are caring for athletic patients must have a thorough understanding of this continuum of injuries, including medial tibial stress syndrome and tibial stress fractures, because there are…

  7. Medial tibial pain. A prospective study of its cause among military recruits.

    PubMed

    Milgrom, C; Giladi, M; Stein, M; Kashtan, H; Margulies, J; Chisin, R; Steinberg, R; Swissa, A; Aharonson, Z

    1986-12-01

    In a prospective study of 295 infantry recruits during 14 weeks of basic training, 41% had medial tibial pain. Routine scintigraphic evaluation in cases of medial tibial bone pain showed that 63% had abnormalities. A stress fracture was found in 46%. Only two patients had periostitis. None had ischemic medial compartment syndrome. Physical examination could not differentiate between cases with medial tibial bone pain secondary to stress fractures and those with scintigraphically normal tibias. When both pain and swelling were localized in the middle one-third of the tibia, the lesion most likely proved to be a stress fracture.

  8. Radiological study of the knee joint line position measured from the fibular head and proximal tibial landmarks.

    PubMed

    Havet, Eric; Gabrion, Antoine; Leiber-Wackenheim, Frederic; Vernois, Joël; Olory, Bruno; Mertl, Patrice

    2007-06-01

    Restoring the joint line level is one of the surgical challenges during revision of total knee arthroplasty. The position of the tibial surface is commonly estimated by its distance to the apex of fibular head, but no study evaluating this distance accurately has been published yet. The purpose of this work was to study the distance between the knee joint line and the apex of the fibular head and the proximal tibia, particularly the tibial tuberosity. Variability with clinical data and relations with other local measurements have been evaluated on knee radiographs (an antero-posterior view, a medio-lateral view and an anteroposterior full length view) of 100 subjects (125 knees). Results showed no correlation between the joint line-fibular head apex distance and any clinical data of the patients, or any other performed measurements. Relations between tibial measurements and the sexe or the height of the subjects were noted. Besides, the review of the 25 bilateral cases did not show statistically significant side difference but the descriptive analysis showed too large discrepancies for the joint line-fibular head apex distance to be used as a landmark. We conclude that the fibular head apex cannot be used as a morphologic landmark to determine the knee joint line position. Its interest in clinical and surgical practice must be discussed.

  9. Physical therapy in the postoperative of proximal femur fracture in elderly. Literature review

    PubMed Central

    Carneiro, Mariana Barquet; Alves, Débora Pinheiro Lédio; Mercadante, Marcelo Tomanik

    2013-01-01

    The proximal femoral fracture in the elderly is a serious public health problem. Surgical treatment of this fracture is used to reduce morbidity, together with postoperative physical therapy. The objective was to conduct a systematic review of physical therapy protocols in postoperative for fractures of the proximal femur in elderly. We selected randomized controlled trials in elderly in the past 10 years, in Portuguese and English. There were 14 articles in the literature. Physical therapy has an important role in functional recovery of the elderly. Level of Evidence I, Systematic Review RCTs (Study results were homogenous). PMID:24453665

  10. [Current treatment situation and progress on bone defect of collapsed tibial plateau fractures].

    PubMed

    Luo, Chang-qi; Fang, Yue; Tu, Chong-qi; Yang, Tian-fu

    2016-02-01

    Characteristics of collapsed tibial plateau fracture determines that the joint surface must remain anatomical reduction,line of force in tibial must exist and internal fixation must be strong. However, while renewing articular surface smoothness, surgeons have a lot of problems in dealing with bone defect under the joint surface. Current materials used for bone defect treatment include three categories: autologous bone, allograft bone and bone substitutes. Some scholars think that autologous bone grafts have a number of drawbacks, such as increasing trauma, prolonged operation time, the limited source, bone area bleeding,continuous pain, local infection and anesthesia,but most scholars believe that the autologous cancellous bone graft is still the golden standard. Allograft bone has the ability of bone conduction, but the existence of immune responses, the possibility of a virus infection, and the limited source of the allograft cannot meet the clinical demands. Likewise, bone substitutes have the problem that osteogenesis does not match with degradation in rates. Clinical doctors can meet the demand of the patient's bone graft according to patient's own situation and economic conditions.

  11. Fatigue fracture of a proximally modular, distally tapered fluted implant with diaphyseal fixation.

    PubMed

    Buttaro, Martín A; Mayor, Michael B; Van Citters, Douglas; Piccaluga, Francisco

    2007-08-01

    We report and analyze the causes of a fracture in a proximally modular, distally tapered fluted MP stem in a 48-year-old woman (168 cm, 67 kg) with severe proximal bone deficiency. Evidence of fatigue failure with striations initiated laterally was observed in the laser etching of the tensile aspect of the prosthesis. However, metallurgical analysis suggested that laser engraving did not alter the microstructure of the stem. Stress due to the absence of proximal femoral bone support may have been sufficiently high to put this particular stem at risk for fatigue fracture. This important complication should be addressed when choosing this therapeutic option in cases with substantial proximal femoral bone loss. Strut allograft support should be recommended in such cases.

  12. Delayed diagnosis of a peroneal artery false aneurysm at a concomitant tibial fracture. A case report.

    PubMed

    Tyllianakis, M; Panagiotopoulos, E; Megas, P; Lambiris, E

    1995-07-01

    A 49-year-old man had posttraumatic persistent calf swelling and a tibial and fibular fracture. Despite the intramedullary nailing of the fracture, the swelling did not improve, and at the 6th postoperative week it was misdiagnosed (using venogram) as deep vein thrombosis. Therefore, it was mistreated with anticoagulants, which led to great deterioration of the local signs. An arteriogram revealed an initially missed false peroneal artery aneurysm. Surgical treatment was performed immediately. The 6-week delay had led to some atrophy of the posterior compartment muscles, fortunately without any permanent disability. The importance of proper and early diagnosis of posttraumatic persistent calf swelling is stressed.

  13. Monoplanar versus biplanar medial open-wedge proximal tibial osteotomy for varus gonarthrosis: a comparison of clinical and radiological outcomes.

    PubMed

    Elmalı, Nurzat; Esenkaya, Irfan; Can, Murat; Karakaplan, Mustafa

    2013-12-01

    We compared clinical and radiological results of two proximal tibial osteotomy (PTO) techniques: monoplanar medial open-wedge osteotomy and biplanar retrotubercle medial open-wedge osteotomy, stabilised by a wedged plate. We evaluated 88 knees in 78 patients. Monoplanar medial open-wedge PTO was performed on 56 knees in 50 patients with a mean age of 55 ± 9 years. Biplanar retrotubercle medial open-wedge PTO was performed on 32 knees in 28 patients with a mean age of 57 ± 7 years. Mean follow-up periods were 40.6 ± 7 months for the monoplanar PTO group and 38 ± 5 months for the biplanar retrotubercle PTO group. Clinical outcome was evaluated using the hospital for special surgery scoring system, and radiological outcome was evaluated by the measurements of femorotibial angle (FTA), patellar height and tibial slope changes. In both groups, post-operative HSS scores increased significantly. No significant difference was found between groups in FTA alteration, but the FTA decreased significantly in both groups. Patellar index ratios decreased significantly in the monoplanar PTO group (Insall-Salvati Index by 0.07, Blackburne-Peel Index by 0.07), but not in the biplanar retrotubercle PTO group. Tibial slopes were increased significantly in the monoplanar PTO group, but not in the retrotubercle PTO group. Biplanar retrotubercle medial open-wedge osteotomy and monoplanar medial open-wedge osteotomy are both clinically effective for the treatment for varus gonarthrosis. Retrotubercle osteotomy also prevents patella infera and tibial slope changes radiologically.

  14. Predictive formula for the length of tibial tunnel in anterior crucitate ligament reconstruction.

    PubMed

    Chernchujit, Bancha; Barthel, Thomas

    2009-12-01

    The anterior cruciate ligament (ACL) reconstruction using bone-patellar tendon bone graft is a common procedure in orthopedics. One challenging problem found is a graft-tunnel mismatch. Previous studies have reported the mathematic formula to predict the tibial angle length and angle to avoid graft-tunnel mismatch but these formulas have shown limited predictability. To propose a predictive formula for the length of tibial tunnel and to examine its predictability. Thirty six patients (26 males, 14 females) with ACL injury were included in this study. The preoperativemedial proximal tibial angle was measured. Intraoperatively, the tibial tunnel length and tibial entry point were measured. The postoperative coronal and saggital angle of tibial tunnel were measured from knee radiograph. The data were analysed by using trigonometry correlation and formulate the predictive formula of tibial tunnel length. We found that tibial tunnel length (T) has trigonometric correlation between the location of tibial tunnel entry point (w), coronal angle of tibial tunnel (b), saggital angle of tibial tunnel (a) and the medial proximal tibial slope (c) by using this formula T = Wcos(c)tan(b)/sin(a) This proposed predictive formula can well predict the length of the tibial tunnel at preoperative period to avoid graft-tunnel mismatch.

  15. [Quality of life and job performance resulting from operatively treated tibial plateau fractures].

    PubMed

    Roßbach, B P; Faymonville, C; Müller, L P; Stützer, H; Isenberg, J

    2016-01-01

    The aim of this article is to present the functional results and the effect on quality of life of surgically treated tibial plateau fractures in physically active and working patients with multiple and serious injuries. In addition, the relationships between functional and radiological outcome were evaluated and compared with activity in daily and professional life. In all, 41 injured patients were followed up a mean of 47 months after surgical treatment and examined with radiological, functional, as well as quality of life score. In the radiological scoring, a mean value of 72 points (max 100 points) was achieved. In the activity score, there was an average of 63.5 points (max 100 points). When evaluating the health-related quality of life, an average score of 69.6 points was achieved. There was a significant relationship between radiological and activity scores and the radiological and life quality scores. Furthermore, the relationship between activity and quality of life scores was considered significant. Surgeon's influence on the functional outcome could be confirmed. The functional and the radiological results were moderate. Quality of life was permanently affected by the consequences of tibial plateau fracture in 12 patients; 11 patients were not re-employed. However, the quality of life was assessed as good or very good and 28 patients had returned to work. The quality of life was firmly linked to the radiological and functional parameters, which tended to be influenced by the quality of the primary surgical treatment when looking at the overall population.

  16. Tibial stress injuries: decisive diagnosis and treatment of 'shin splints'.

    PubMed

    Couture, Christopher J; Karlson, Kristine A

    2002-06-01

    Tibial stress injuries, commonly called 'shin splints,' often result when bone remodeling processes adapt inadequately to repetitive stress. Physicians who care for athletic patients need a thorough understanding of this continuum of injuries, including medial tibial stress syndrome and tibial stress fractures, because there are implications for appropriate diagnosis, management, and prevention.

  17. The soleal line: a cause of tibial pseudoperiostitis.

    PubMed

    Levine, A H; Pais, M J; Berinson, H; Amenta, P S

    1976-04-01

    An unusually prominent soleal line (a normal anatomic variant) may mimic periosteal reaction along the posterior margin of the proximal tibial shaft. This area of pseudoperiostitis is differentiated from hyperostoses arising from the anterior tibial tubercle and the interosseous membrane. It is always associated with normal, undisturbed architecture of the underlying bone.

  18. Bilateral double level tibial lengthening in dwarfism.

    PubMed

    Burghardt, Rolf D; Yoshino, Koichi; Kashiwagi, Naoya; Yoshino, Shigeo; Bhave, Anil; Paley, Dror; Herzenberg, John E

    2015-12-01

    Outcome assessment after double level tibial lengthening in patients with dwarfism. Fourteen patients with dwarfism were analyzed after bilateral simultaneous double level tibial lengthening. Average age was 15.1 years. Average lengthening was 13.5 cm. The two levels were lengthened by an average of 7.5 cm proximally and 6.0 cm distally. Concomitant deformities were also addressed during lengthening. External fixation treatment time averaged 8.8 months. Healing index averaged 0.7 months/cm. Bilateral tibial lengthening for dwarfism is difficult, but the results are usually quite gratifying.

  19. Virtual stress testing of fracture stability in soldiers with severely comminuted tibial fractures.

    PubMed

    Petfield, Joseph L; Hayeck, Garry T; Kopperdahl, David L; Nesti, Leon J; Keaveny, Tony M; Hsu, Joseph R

    2017-04-01

    Virtual stress testing (VST) provides a non-invasive estimate of the strength of a healing bone through a biomechanical analysis of a patient's computed tomography (CT) scan. We asked whether VST could improve management of patients who had a tibia fracture treated with external fixation. In a retrospective case-control study of 65 soldier-patients who had tibia fractures treated with an external fixator, we performed VST utilizing CT scans acquired prior to fixator removal. The strength of the healing bone and the amount of tissue damage after application of an overload were computed for various virtual loading cases. Logistic regression identified computed outcomes with the strongest association to clinical events related to nonunion within 2 months after fixator removal. Clinical events (n = 9) were associated with a low tibial strength for compression loading (p < 0.05, AUC = 0.74) or a low proportion of failed cortical bone tissue for torsional loading (p < 0.005, AUC = 0.84). Using post-hoc thresholds of a compressive strength of four times body-weight and a proportional of failed cortical bone tissue of 5%, the test identified all nine patients who failed clinically (100% sensitivity; 40.9% positive predictive value) and over three fourths of those (43 of 56) who progressed to successful healing (76.8% specificity; 100% negative predictive value). In this study, VST identified all patients who progressed to full, uneventful union after fixator removal; thus, we conclude that this new test has the potential to provide a quantitative, objective means of identifying tibia-fracture patients who can safely resume weight bearing. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:805-811, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  20. [Fractures of the proximal interphalangeal joint: Diagnostic and operative therapy options].

    PubMed

    Unglaub, F; Langer, M F; Hahn, P; Müller, L P; Ahrens, C; Spies, C K

    2016-02-01

    Joint fractures of the fingers often entail operative interventions in contrast to extra-articular fractures. These types of fracture are inclined to dislocate in addition to the actual fracture. The proximal interphalangeal (PIP) joint in particular often shows comminuted fractures due to the long leverage of the finger and a relatively small diameter of the joint. The clinical examination, X-ray diagnostics and if necessary computed tomography allow the classification into stable and unstable fractures. Unstable fractures must be treated by surgical reduction and fixation. A multitude of operative techniques are available for these mostly complicated fractures. The foremost goal is a stable osteosynthesis of the fracture with repositioning of the dislocation, which enables early physiotherapy in order to prevent tendon adhesion and contracture. This article presents the different types of PIP joint fractures, their specific surgical treatment and postoperative treatment regimens.

  1. Interventions for treating proximal humeral fractures in adults.

    PubMed

    Handoll, Helen H G; Brorson, Stig

    2015-11-11

    Fracture of the proximal humerus, often termed shoulder fracture, is a common injury in older people. The management of these fractures varies widely. This is an update of a Cochrane Review first published in 2001 and last updated in 2012. To assess the effects (benefits and harms) of treatment and rehabilitation interventions for proximal humeral fractures in adults. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, and other databases, conference proceedings and bibliographies of trial reports. The full search ended in November 2014. We considered all randomised controlled trials (RCTs) and quasi-randomised controlled trials pertinent to the management of proximal humeral fractures in adults. Both review authors performed independent study selection, risk of bias assessment and data extraction. Only limited meta-analysis was performed. We included 31 heterogeneous RCTs (1941 participants). Most of the 18 separate treatment comparisons were tested by small single-centre trials. The main exception was the surgical versus non-surgical treatment comparison tested by eight trials. Except for a large multicentre trial, bias in these trials could not be ruled out. The quality of the evidence was either low or very low for all comparisons except the largest comparison.Nine trials evaluated non-surgical treatment in mainly minimally displaced fractures. Four trials compared early (usually one week) versus delayed (three or four weeks) mobilisation after fracture but only limited pooling was possible and most of the data were from one trial (86 participants). This found some evidence that early mobilisation resulted in better recovery and less pain in people with mainly minimally displaced fractures. There was evidence of little difference between the two groups in shoulder complications (2/127 early mobilisation versus 3/132 delayed mobilisation; 4 trials) and

  2. Is intramedullary nailing applicable for distal tibial fractures with ankle joint extension?

    PubMed

    Beytemür, Ozan; Albay, Cem; Adanır, Oktay; Yüksel, Serdar; Güleç, Mehmet Akif

    2016-12-01

    This study aims to evaluate the functional and radiographic results and treatment complications of AO/OTA (Arbeitsgemeinschaft fur Osteosynthesefragen/Orthopaedic Trauma Association) type 43C1 and C2 fractures treated with intramedullary nailing. We retrospectively evaluated 35 AO/OTA type 43C1 and C2 patients (26 males, 9 females; mean age 39.8±16.9 years; range 19 to 82 years) treated with intramedullary nailing. Two interfragmentary screws out of nail were applied in 10 patients (29%), while one interfragmentary screw out of nail was applied in 17 patients (49%). Intramedullary nailing was applied in eight patients (23%) without external screws. Fracture union, union time, alignment problems, and complications were evaluated. Clinical evaluation of patients was conducted using the Olerud and Molander score and by measuring the ankle joint range of motion. Union was achieved in all 35 patients. Mean union time was 16.5±2.8 weeks (range 12 to 24 weeks) and mean Olerud and Molander score was 88±8.24. Varus deformity was detected in one patient, valgus deformity was detected in two patients, and rotation deformity was detected in one patient. Superficial infection was detected in three patients (9%). Deep infection was not detected in any patient. Intramedullary nailing is not contraindicated for simple intra-articular distal tibial fractures. In these fractures, intramedullary nailing performed in accordance with its technique, with an additional percutaneous screw if necessary, is a successful treatment option with high fracture union rates, high functional results, and low complication rates.

  3. Intraoperative Proximal Femoral Fracture in Primary Cementless Total Hip Arthroplasty.

    PubMed

    Ponzio, Danielle Y; Shahi, Alisina; Park, Andrew G; Purtill, James J

    2015-08-01

    Intraoperative proximal femoral fracture is a complication of primary cementless total hip arthroplasty (THA) at rates of 2.95-27.8%. A retrospective review of 2423 consecutive primary cementless THA cases identified 102 hips (96 patients) with fracture. Multivariate analysis compared fracture incidences between implants, Accolade (Stryker Orthopaedics) and Tri-Lock (DePuy Orthopaedics, Inc.), and evaluated potential risk factors using a randomized control group of 1150 cases without fracture. The fracture incidence was 4.4% (102/2423), 3.7% (36/1019) using Accolade and 4.9% using Tri-Lock (66/1404) (P=0.18). Female gender (OR=1.96; 95% CI 1.19-3.23; P=0.008) and smaller stem size (OR=1.64; 95% CI 1.04-2.63; P=0.03) predicted increased odds of fracture. No revisions of the femoral component were required in the fracture cohort. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. [Treatment of periprosthetic and peri-implant fractures : modern plate osteosynthesis procedures].

    PubMed

    Raschke, M J; Stange, R; Kösters, C

    2012-11-01

    Periprosthetic fractures are increasing not only due to the demographic development with high life expectancy, the increase in osteoporosis and increased prosthesis implantation but also due to increased activity of the elderly population. The therapeutic algorithms are manifold but general valid rules for severe fractures are not available. The most commonly occurring periprosthetic fractures are proximal and distal femoral fractures but in the clinical routine fractures of the tibial head, ankle, shoulder, elbow and on the borders to other implants (peri-implant fractures) and complex interprosthetic fractures are being seen increasingly more. It is to be expected that in the mid-term further options, such as cement augmentation of cannulated polyaxial locking screws will extend the portfolio of implants for treatment of periprosthetic fractures. The aim of this review article is to present the new procedures for osteosynthesis of periprosthetic fractures.

  5. [Treatment of periprosthetic and peri-implant fractures : modern plate osteosynthesis procedures].

    PubMed

    Raschke, M J; Stange, R; Kösters, C

    2012-08-01

    Periprosthetic fractures are increasing not only due to the demographic development with high life expectancy, the increase in osteoporosis and increased prosthesis implantation but also due to increased activity of the elderly population. The therapeutic algorithms are manifold but general valid rules for severe fractures are not available. The most commonly occurring periprosthetic fractures are proximal and distal femoral fractures but in the clinical routine fractures of the tibial head, ankle, shoulder, elbow and on the borders to other implants (peri-implant fractures) and complex interprosthetic fractures are being seen increasingly more. It is to be expected that in the mid-term further options, such as cement augmentation of cannulated polyaxial locking screws will extend the portfolio of implants for treatment of periprosthetic fractures. The aim of this review article is to present the new procedures for osteosynthesis of periprosthetic fractures.

  6. Sequential avulsions of the tibial tubercle in an adolescent basketball player.

    PubMed

    Huang, Ying Chieh; Chao, Ying-Hao; Lien, Fang-Chieh

    2010-05-01

    Tibial tubercle avulsion is an uncommon fracture in physically active adolescents. Sequential avulsion of tibial tubercles is extremely rare. We reported a healthy, active 15-year-old boy who suffered from left tibial tubercle avulsion fracture during a basketball game. He received open reduction and internal fixation with two smooth Kirschner wires and a cannulated screw, with every effort to reduce the plate injury. Long-leg splint was used for protection followed by programmed rehabilitation. He recovered uneventfully and returned to his previous level of activity soon. Another avulsion fracture happened at the right tibial tubercle 3.5 months later when he was playing the basketball. From the encouragement of previous successful treatment, we provided him open reduction and fixation with two small-caliber screws. He recovered uneventfully and returned to his previous level of activity soon. No genu recurvatum or other deformity was happening in our case at the end of 2-year follow-up. No evidence of Osgood-Schlatter disease or osteogenesis imperfecta was found. Sequential avulsion fractures of tibial tubercles are rare. Good functional recovery can often be obtained like our case if we treat it well. To a physically active adolescent, we should never overstate the risk of sequential avulsion of the other leg to postpone the return to an active, functional life.

  7. [Incidence of proximal femur fractures in relation to seasons of the year and weather].

    PubMed

    Burget, F; Pleva, L; Kudrna, K; Kudrnová, Z

    2012-01-01

    The opinion that proximal femur fractures occur mainly in the winter season and are related to slippery surfaces prevails in both the lay and medical communities. The elucidation of this relationship would lead to a better understanding of the aetiology of these fractures and may help to prevent them in the elderly population. In a retrospective study conducted at two departments, the occurrence of proximal femur fractures in patients 60+ years old in relation to weather conditions (air temperature and its humidity, atmospheric pressure, rain and mist) between January 1, 2001 and December 31, 2005 was investigated. Patients with high-energy or pathological fractures were excluded. The results were evaluated by Statistika software. A total of 1720 patients were studied, of whom 1313 were women and 407 were men. The numbers of fractures did not differ significantly among either the seasons or months of the year. No correlation was found between the number of fractures and each of the weather characteristics (air temperature and its humidity, atmospheric pressure, wind speed and visibility). It is widely believed that hip fractures are connected with winter months and temperatures below zero. This is supported by several facts related to winter characteristics, such as slippery icy pavements, clumsiness due to warm bulky clothes, bodies affected by cold and thus predisposed to a fall and poorer visibility on shorter winter days. The effect of seasonal variation on hip fracture incidence has been investigated in 10 studies of which only one has taken the influence of daily temperature into consideration. All studies were conduced in the countries north of 40° latitude, i.e., in climatic conditions similar to our country, with temperatures falling below zero and ice-glazed pavements in winter months. Of them, six have found no relation between proximal femur fractures and weather conditions, two have reported an increased incidence of these fractures in winter months

  8. Second generation locked plating for complex proximal humerus fractures in very elderly patients.

    PubMed

    Gavaskar, Ashok S; Karthik B, Bhupesh; Tummala, Naveen C; Srinivasan, Parthasarathy; Gopalan, Hitesh

    2016-11-01

    Humeral head sacrificing procedures are more favored in elderly patients with complex proximal humerus fractures because of high incidence of failures and complications with osteosynthesis. The purpose of this study is to assess the outcome of second generation locked plating techniques in 3 and 4 part fractures in active elderly patients >70years with an emphasis on function and complications. 29 patients with displaced 3 and 4 part proximal humerus fractures were treated using the principles of second-generation proximal humerus locked plating. Fixed angle locked plating (PHILOS) using the anterolateral deltoid spilt approach augmented with traction cuff sutures was performed. Minimum of 7 locking head screws including 2 calcar screws were used. In cases with a comminuted medial calcar, an endosteal fibular strut was used. Subchondral metaphyseal bone voids were filled with injectable calcium phosphate cement. Radiological outcome (union, head - shaft angle, tuberosity reduction), functional outcome assessment (Constant and ASES scores) and complications (loss of reduction, nonunion and osteonecrosis) were assessed. The fracture united in 24 of the 26 patients available for follow up at a mean of 27 months (12-40 months). 3 patients developed complications that required arthroplasty (fixation failure in 2 patients and osteonecrosis in 1 patient). Follow up age adjusted Constant (63.1±11.9) and ASES scores (62.58±7.5) showed the extent of functional improvement post surgery. Patients with fractures having a non-comminuted medial calcar and valgus displacement of the humeral head had better functional scores and fewer complications. Osteosynthesis with second generation locked plating techniques provide satisfactory outcome in very elderly patients with complex proximal humerus fractures with minimal complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Proximal fractures of the humerus in patients older than 75 years of age: should we consider operative treatment?

    PubMed

    de Kruijf, Marjolein; Vroemen, J P A M; de Leur, K; van der Voort, E A M; Vos, D I; Van der Laan, L

    2014-06-01

    Over 75 % of patients presenting with a proximal humerus fracture are 70 years or older. Very little is known about the outcome after operative treatment of these fractures in very old patients. This study was performed to gain more insight in safety and functional outcome of surgical treatment of proximal humerus fractures in the elderly. In this observational study, we analyzed all operatively treated patients, aged 75 or older, with a proximal humerus fracture between January 2003 and December 2008 in our center. Patient selection was on clinical grounds, based on physical, mental, and social criteria. Complications were evaluated. We used the DASH Questionnaire to investigate functional outcome, pain, and ADL limitations. Sixty-four patients were treated surgically for a displaced proximal fracture of the humerus: 15 two-part, 32 three-part, and 17 four-part fractures. Mean DASH scores were 37.5, 36.9, and 48.6, respectively. Regarding the operative methods, overall good results were obtained with the modern locked plate osteosynthesis (mean DASH 34.4). Prosthetic treatment, mostly used in highly comminuted fractures, often resulted in poor function (mean DASH 72.9). Persistent pain and ADL limitations were more present in more comminuted fractures (64 and 50 % in patients with 4-part fractures vs. 14 % in 2-part fractures). There were no postoperative deaths within 3 months of surgery, and fracture-related and non-fracture-related complication rates were low (non-union 3 %; 1 myocardial infarction). This study shows that it is safe and justifiable to consider surgical treatment of a severely dislocated proximal humerus fracture in selected patients aged 75 and older. According to OCEBM Working Group,Level IV.

  10. Comparative study of single lateral locked plating versus double plating in type C bicondylar tibial plateau fractures.

    PubMed

    Neogi, Devdatta Suhas; Trikha, Vivek; Mishra, Kaushal Kant; Bandekar, Shivanand M; Yadav, Chandra Shekhar

    2015-01-01

    Bicondylar tibial plateau fractures are complex injuries and treatment is challenging. Ideal method is still controversial with risk of unsatisfactory results if not treated properly. Many different techniques of internal and external fixation are used. This study compares the clinical results in single locked plating versus dual plating (DP) using two incision approaches. Our hypothesis was that DP leads to less collapse and change in alignment at final followup compared with single plating. 61 cases of Type C tibial plateau fractures operated between January 2007 and June 2011 were included in this prospective study. All cases were operated either by single lateral locked plate by anterolateral approach or double plating through double incision. All cases were followed for a minimum of 24 months radiologically and clinically. The statistical analysis was performed using software SPSS 10.0 to analyze the data. Twenty nine patients in a single lateral locked plate and 32 patients in a double plating group were followed for minimum 2 years. All fractures healed, however there was a significant incidence of malalignment in the single lateral plating group. Though there was a significant increase in soft tissue issues with the double plating group; however, there was only 3.12% incidence of deep infection. There was no significant difference in Hospital for special surgery score at 2 years followup. Double plating through two incisions resulted in a better limb alignment and joint reduction with an acceptable soft tissue complication rate.

  11. Management of comminuted proximal ulna fracture-dislocations using a multiplanar locking intramedullary nail.

    PubMed

    Edwards, Scott G; Argintar, Evan; Lamb, Joshua

    2011-06-01

    Intramedullary nails have been used for the fixation of olecranon fractures in an attempt to reduce the soft tissue irritation and resulting need for hardware removal seen with plating and tension banding. Further benefits include preservation of vascular supply, and increase stability and improved compression over some alternative techniques. Most intramedullary nails have been limited to simple olecranon fractures or osteotomies. One novel multiplanar, locking intramedullary nail, however, is indicated to stabilize all fracture patterns of the proximal ulna, including the coronoid. This particular locking nail has screws that radiate in multiple planes and form a fixed-angle lattice throughout the bone. The nail also has fixed-angle screws dedicated to the 3 parts of the coronoid: process tip, medial facet, and medial wall. This allows the nail to secure multiple fragments regardless of the fracture pattern's extent of instability. The objective of this article is to illustrate the recommended steps in reducing and stabilizing a comminuted proximal ulna fracture-dislocation using this multiplanar locking intramedullary nail.

  12. Plantar Plating for the Treatment of Proximal Fifth Metatarsal Fractures in Elite Athletes.

    PubMed

    Mitchell, Ronald J; Duplantier, Neil L; Delgado, Domenica A; Lambert, Bradley S; McCulloch, Patrick C; Harris, Joshua D; Varner, Kevin E

    2017-05-01

    Proximal fifth metatarsal fractures, zones II and III, are commonly treated surgically, especially in elite athletes. Intramedullary screw fixation remains the most used construct despite nonunion and refracture. High tensile forces on the plantar-lateral aspect of the fifth metatarsal are difficult to control, and intramedullary screw fixation depends on ideal screw position, length, and width. The authors present a plantar plating technique with cancellous bone autograft for zones II and III proximal fifth metatarsal fractures. Rotational instability and plantar-lateral gapping are resisted by applying a compression plate to the tension side of the fracture, eliminating causes for failure. [Orthopedics. 2017; 40(3):e563-e566.]. Copyright 2017, SLACK Incorporated.

  13. Bioactive glass granules: a suitable bone substitute material in the operative treatment of depressed lateral tibial plateau fractures: a prospective, randomized 1 year follow-up study.

    PubMed

    Heikkilä, Jouni T; Kukkonen, Juha; Aho, Allan J; Moisander, Susanna; Kyyrönen, Timo; Mattila, Kimmo

    2011-04-01

    Purpose of this study was to compare bioactive glass and autogenous bone as a bone substitute material in tibial plateau fractures. We designed a prospective, randomized study consisting of 25 consecutive operatively treated patients with depressed unilateral tibial comminuted plateau fracture (AO classification 41 B2 and B3).14 patients (7 females, 7 males, mean age 57 years, range 25-82) were randomized in the bioglass group (BG) and 11 patients (6 females, 5 males, mean age 50 years, range 31-82) served as autogenous bone control group (AB). Clinical examination of the patients was performed at 3 and 12 months, patients' subjective and functional results were evaluated at 12 months. Radiological analysis was performed preoperatively, immediately postoperatively and at 3 and 12 months. The postoperative redepression for both studied groups was 1 mm until 3 months and remained unchanged at 12 months. No differences were identified in the subjective evaluation, functional tests and clinical examination between the two groups during 1 year follow-up. We conclude that bioactive glass granules can be clinically used as filler material instead of autogenous bone in the lateral tibial plateau compression fractures.

  14. MRI Anatomy of the Tibial ACL Attachment and Proximal Epiphysis in a Large Population of Skeletally Immature Knees: Reference Parameters for Planning Anatomic Physeal-Sparing ACL Reconstruction.

    PubMed

    Swami, Vimarsha Gopal; Mabee, Myles; Hui, Catherine; Jaremko, Jacob Lester

    2014-07-01

    To aid in performing anatomic physeal-sparing anterior cruciate ligament (ACL) reconstruction, it is important for surgeons to have reference data for the native ACL attachment positions and epiphyseal anatomy in skeletally immature knees. To characterize anatomic parameters of the ACL tibial insertion and proximal tibial epiphysis at magnetic resonance imaging (MRI) in a large population of skeletally immature knees. Cross-sectional study; Level of evidence, 3. The ACL tibial attachment site and proximal epiphysis were examined in 570 skeletally immature knees with an intact ACL (age, 6-15 years) using 1.5-T proton density-weighted sagittal MRI; also measured were the tibial anteroposterior diameter; anterior, central, and posterior ACL attachment positions; vertical height of the epiphysis; and maximum oblique epiphyseal depth extending from the ACL tibial attachment center to the tibial tuberosity. In adolescents (11-15 years of age), the center of the ACL's tibial attachment was 51.5% ± 5.7% of the anteroposterior diameter of the tibia, with no significant differences between sexes or age groups (P > .05 in all cases). Mean vertical epiphyseal height was 15.9 ± 1.7 mm in the adolescent group, with significant differences between 11-year-olds (15.2 ± 1.5 mm) and 15-year-olds (16.6 ± 1.6 mm), P < .001, and between males (16.6 ± 1.5 mm) and females (14.8 ± 1.4), P < .001. Mean maximum oblique depth was 30.0 ± 5.3 mm, with a significant difference between 11-year-olds (26.7 ± 4.9 mm) and 15-year-olds (32.7 ± 5.1 mm), P < .001, and between males (29.7 ± 6.4 mm) and females (27.8 ± 5.2 mm), P < .001. The maximum oblique depth occurred at a mean angle of ~50°, and this angle did not change with age or sex. There was a significant moderate correlation (r = 0.39, P < .001) between epiphyseal vertical height and maximum oblique depth. The center of the ACL tibial attachment was consistently near 51% of the anteroposterior diameter, regardless of age or sex

  15. Anatomic mapping for surgical reconstruction of the proximal tibiofibular ligaments.

    PubMed

    See, Aaron; Bear, Russell R; Owens, Brett D

    2013-01-01

    Injury to the proximal tibiofibular joint is uncommon. Previous studies regarding the anatomy of this region have predominantly focused on joint orientation. As radiographic technology has advanced, later studies have attempted to evaluate the capsular anatomy. However, no reports specifically map the ligaments to this joint. The objectives of the current study were to define specific ligamentous structures that provide stability to the proximal tibiofibular joint, describe easily identifiable and reproducible surgical landmarks to aid in surgical reconstruction, and add to the understanding of the posterolateral structures of the knee previously described by other authors. The proximal tibiofibular joint ligaments were identified in 10 fresh-frozen cadaveric specimens. Average ligament length, width, and thickness and area of the footprints of the tibial and fibular attachments were measured. Distances from the ligament footprints to known anatomic landmarks (eg, Gerdy's tubercle, tibial articular surface, and fibular styloid) were also measured. The anterior ligament tibial attachment was a mean of 15.6 mm lateral and posterior to Gerdy's tubercle and 17.3 mm anterior and inferior from the fibular styloid. Posterior ligament tibial insertion was a mean of 15.7 mm inferior to the tibial articular surface on the tibial side and 14.2 mm medial and slightly inferior from the fibular styloid. Definable ligaments provide stability to the proximal tibiofibular joint and can be reconstructed in an anatomic fashion using the landmarks and parameters described. This information allows for an anatomic reconstruction of the proximal tibiofibular joint, which should provide patients with better outcomes and fewer postoperative sequelae. Copyright 2013, SLACK Incorporated.

  16. Fractures of the proximal fifth metatarsal: percutaneous bicortical fixation.

    PubMed

    Mahajan, Vivek; Chung, Hyun Wook; Suh, Jin Soo

    2011-06-01

    Displaced intraarticular zone I and displaced zone II fractures of the proximal fifth metatarsal bone are frequently complicated by delayed nonunion due to a vascular watershed. Many complications have been reported with the commonly used intramedullary screw fixation for these fractures. The optimal surgical procedure for these fractures has not been determined. All these observations led us to evaluate the effectiveness of percutaneous bicortical screw fixation for treating these fractures. Twenty-three fractures were operatively treated by bicortical screw fixation. All the fractures were evaluated both clinically and radiologically for the healing. All the patients were followed at 2 or 3 week intervals till fracture union. The patients were followed for an average of 22.5 months. Twenty-three fractures healed uneventfully following bicortical fixation, with a mean healing time of 6.3 weeks (range, 4 to 10 weeks). The average American Orthopaedic Foot & Ankle Society (AOFAS) score was 94 (range, 90 to 99). All the patients reported no pain at rest or during athletic activity. We removed the implant in all cases at a mean of 23.2 weeks (range, 18 to 32 weeks). There was no refracture in any of our cases. The current study shows the effectiveness of bicortical screw fixation for displaced intraarticular zone I fractures and displaced zone II fractures. We recommend it as one of the useful techniques for fixation of displaced zone I and II fractures.

  17. Functional and Radiological Outcome of Schatzker type V and VI Tibial Plateau Fracture Treatment with Dual Plates with Minimum 3 years follow-up: A Prospective Study

    PubMed Central

    Suri, Harpreet Singh; Gangrade, Kewal

    2016-01-01

    Introduction High energy intra-articular fractures involving the tibial plateau causes various problems related to management like wound dehiscence, severe comminution leading to malalignment and delayed complications like varus collapse, implant failure and arthritis of knee joint. Aim This study was done to determine functional, radiological outcome and the complications of Schatzker V and VI tibial plateau fractures treated with bipillar plating with dual plates with a regular follow-up of atleast 3 years. Materials and Methods Total 34 cases of tibial plateau fracture type V and VI treated with dual plating were studied from January 2011 to December 2013 in KIMS Hospital were followed for minimum of 3 years. The patients were operated through an anterolateral approach for lateral plate and a medial column plate was put through a minimally invasive medial approach or an open posteromedial approach. Results Total 34 patients were evaluated postoperatively thoroughly for functional outcome using The Knee Society Score and radiological outcomes by Modified Rasmussen Assessment criteria which showed 29 patients (85.29%) had excellent and 5 patients (14.71%) had good objective knee society score. 24 patients (70.59%) had excellent, 8 patients (23.53%) had good and 1patient (2.94%) were each of poor and fair functional knee society score. Eleven patients (32.35%) had excellent, 21patients (61.76%) had good and 2 patients (5.88%) had fair radiological outcome. Conclusion We conclude that open reduction and internal fixation of high-energy tibial plateau fractures with dual plates via 2 incisions gives excellent to good functional outcome with minimal soft tissue complications. Thus, a minimally invasive approach should be used which helps in preventing soft tissue problems and helps in early wound healing. Fixation done by bipillar plating is important for early mobilization of knee joint. Early mobilization leads to better range of movements and thereby better

  18. Comparative study of single lateral locked plating versus double plating in type C bicondylar tibial plateau fractures

    PubMed Central

    Neogi, Devdatta Suhas; Trikha, Vivek; Mishra, Kaushal Kant; Bandekar, Shivanand M.; Yadav, Chandra Shekhar

    2015-01-01

    Background: Bicondylar tibial plateau fractures are complex injuries and treatment is challenging. Ideal method is still controversial with risk of unsatisfactory results if not treated properly. Many different techniques of internal and external fixation are used. This study compares the clinical results in single locked plating versus dual plating (DP) using two incision approaches. Our hypothesis was that DP leads to less collapse and change in alignment at final followup compared with single plating. Materials and Methods: 61 cases of Type C tibial plateau fractures operated between January 2007 and June 2011 were included in this prospective study. All cases were operated either by single lateral locked plate by anterolateral approach or double plating through double incision. All cases were followed for a minimum of 24 months radiologically and clinically. The statistical analysis was performed using software SPSS 10.0 to analyze the data. Results: Twenty nine patients in a single lateral locked plate and 32 patients in a double plating group were followed for minimum 2 years. All fractures healed, however there was a significant incidence of malalignment in the single lateral plating group. Though there was a significant increase in soft tissue issues with the double plating group; however, there was only 3.12% incidence of deep infection. There was no significant difference in Hospital for special surgery score at 2 years followup. Conclusion: Double plating through two incisions resulted in a better limb alignment and joint reduction with an acceptable soft tissue complication rate. PMID:26015609

  19. Expandable proximal femoral nail versus gamma proximal femoral nail for the treatment of AO/OTA 31A1-3 fractures.

    PubMed

    Michael, Drexler; Yaniv, Warschawski; Tal, Frenkel Rutenberg; Kessler Evan, G; Eyal, Amar; Nimrod, Snir; Ehud, Rath; Gilad, Eizenberg; Ely, Steinberg L

    2016-02-01

    The gamma-proximal femoral nail (GPFN) and the expandable proximal femoral nail (EPFN) are two commonly used intramedullary devices for the treatment of AO 31A1-3 proximal femur fractures. The aim of this study was to compare outcomes and complication rates in patients treated by both devices. A total of 299 patients (149 in the GPFN group and 150 in the EPFN group, average age 83.6 years) were treated for AO 31A1-3 proximal femur fractures in our institution between July 2008 and February 2013. Time from presentation to surgery, level of experience of the surgeon, operative time, amount of blood loss and number of blood transfusions were recorded. Postoperative radiological variables, including peg/screw location, tip to apex distance and orthopaedic complications, as, malunion, nonunion, surgical wound infection rates, cutouts, periprosthetic fractures and the incidence of non-orthopaedic complications. Functional results were estimated using the modified Harris Hip Score, and quality of life was queried by the SF-36 questionnaire. The GPFN and the EPFN fixation methods were similar in terms of functional outcomes, complication rates and quality of life assessments. More patients (107 vs. 73) from the GPFN group were operated within 48 h from presentation (44.8 h vs. 49.9 h for the EPFN group, p=0.351), and their surgery duration and hospitalisation were significantly longer (18.5 days vs. 26 days, respectively, p<0.001). The GPFN patients were frequently operated by junior surgeons: 90% (135) while 50.6% (76) of the EPFN operations were performed by senior doctors. Other intraoperative measures were similar between groups. Cutout was the most common complication affecting 6.7% of the GPFN group and 3.3% of the EPFN group (p=0.182). Good clinical outcomes and low complication rates in the GPFN and the EPFN groups indicate essentially equivalent safety and reliability on the part of both devices for the treatment of proximal femoral fractures. Copyright © 2015

  20. Early Functional Treatment of Proximal Phalanx Fractures in Children: A Case Series Study.

    PubMed

    Bohr, Stefan; Mammadli, Toghrul

    2018-05-23

    The objective of this study was to assess proper indications a nonsurgical treatment regime for pediatric fractures of the proximal phalanx based on principles of early functional treatment. A case series (evidence level 4) of 30 pediatric patients with fractures of the proximal phalanx were treated nonsurgically using protective dynamic splinting techniques and fiberglass casting material. Assessments were performed clinically and by x-ray within 4 to 8 weeks of commencement of treatment. Outcome measures included Disabilities of the Arm, Shoulder, and Hand score questionnaire as well as fingertip palm distance (cm) and dynamic pain interval assessments. All fractures healed without any clinically apparent bony deformities. Disabilities of the Arm, Shoulder, and Hand scores were of 25.17 ± 5.29 (mean ± SD), which indicated good functional results usually within 2 weeks of removal of dynamic splints. Fingertip palm distance measurements at endpoints were of 0.17 ± 0.27 cm (mean ± SD), which indicated an almost free range of finger motion. Absence of pain perception under active finger motion (dynamic pain interval) was noted at 14.10 ± 6.79 days (mean ± SD). Well-established criteria for surgical treatment of phalangeal fractures exist. However, in our experience, a majority of pediatric fractures of the proximal phalanx can be safely treated nonsurgically with dynamic splinting along with shorter intervals of immobilization of the affected fingers and faster restoration of overall hand function compared to surgical treatment.

  1. [Curative efficacies of mini-invasive percutaneous osteosynthesis versus supercutaneous plating for distal tibial fractures].

    PubMed

    He, Xianfeng; Zhu, Limei; Zhang, Jingwei; Li, Ming; Yu, Yihui

    2014-12-30

    To compare the clinical efficacies of mini-invasive percutaneous osteosynthesis (MIPO) versus supercutaneous plating with closed reduction in the treatment of distal tibial fractures. A total of 48 patients with close distal tibial fractures were treated between January 2010 and January 2012. The MIPO group included 16 males and 8 females with an average age of 36 years. And the types were A (n = 15), B (n = 6) and C (n = 3) according to the classification scheme of Association for the Study of Internal Fixation (AO/ASIF). The supercutaneous plating group also included 16 males and 8 females with an average age of 37 years. And the types were A (n = 15), B (n = 6) and C (n = 3). And the operative duration, hospital stay, union time, postoperative complications and function of ankle were compared between two groups. The mean follow-up period was 18.5 (12-26) months. There was no instance of nonunion, hardware breakdown or deep infection. Patients in supercutaneous plating group had significantly shorter mean operative duration, hospital stay and union time. Three patients and 1 patient in MIPO group presented with superficial infection and delayed union respectively while there was no occurrence in supercutaneous plating group. And the differences were not statistically significant. Fifteen patients (62.5%) complained of implant impingement or discomfort. And stripping occurred at an incidence of 15.6% during the removal time of locking screws in MIPO group. While in supercutaneous plating group, there as no complaint of skin irritation and removal of supercutaneous plate was easily performed without anesthesia. The mean AOFAS score was 90.7 ± 3.8 in supercutaneous plating group versus 88.9 ± 4.1 in MIPO group (P = 0.070). Distal tibia fractures may be treated successfully with MIPO or supercutaneous plating. However, supercutaneous plating offers multiple advantages in terms of mean operative duration, hospital stay, union time, skin irritation and implant

  2. Influence of age on delayed surgical treatment of proximal femoral fractures

    PubMed Central

    Gomes, Lisiane Pinto; do Nascimento, Leandra Delfim; Campos, Tulio Vinicius de Oliveira; Paiva, Edson Barreto; de Andrade, Marco Antonio Percope; Guimarães, Henrique Cerqueira

    2015-01-01

    ABSTRACT OBJECTIVE : To investigate the influence of patients' age on the delay between diagnosis and surgical treatment of proximal femoral fractures METHODS : This is a retrospective study, con-ducted at a tertiary university hospital, including all patients admitted with proximal femoral fractures between March 2013 and March 2014. The participants were categorized into four groups according to age levels. The groups were compared according to demographics, comorbidities, fracture type, trau-ma circumstances, and time between diagnosis and surgical procedure RESULTS : One hundred and sixty one patients were included, 37 adults and 124 elderly. Among adults, the mean delay between diagnosis and surgical procedure was 6.4±5.3 days; among elderly the delay was 9.5±7.6 days. There was a progressive increase in the delay from the young-adults group through the elderly individuals (Kruskal-Wallis: 13.7; p=0.003) CONCLUSION : In spite of being the patients most susceptible to complications due to surgical delay, the elderly individuals pre-sented the longest delays from admission to surgical treatment. Level of Evidence III, Retrospective Study. PMID:27057145

  3. Are certain fractures at increased risk for compartment syndrome after civilian ballistic injury?

    PubMed

    Meskey, Thomas; Hardcastle, John; O'Toole, Robert V

    2011-11-01

    Compartment syndrome after ballistic fracture is uncommon but potentially devastating. Few data are available to help guide clinicians regarding risk factors for developing compartment syndrome after ballistic fractures. Our primary hypothesis was that ballistic fractures of certain bones would be at higher risk for development of compartment syndrome. A retrospective review at a Level I trauma center from 2001 through 2007 yielded 650 patients with 938 fractures resulting from gunshots. We reviewed all operative notes, clinic notes, discharge summaries, and data from our prospective trauma database. Cases in which the attending orthopedic surgeon diagnosed compartment syndrome and performed fasciotomy were considered cases with compartment syndrome. We excluded all prophylactic fasciotomies. Univariate analyses were conducted to identify risk factors associated with development of compartment syndrome. Twenty-six (2.8%) of the 938 fractures were associated with compartment syndrome. Only fibular (11.6%) and tibial (11.4%) fractures had incidence significantly higher than baseline for all ballistic fractures (p < 0.001). Fractures of the proximal third of the fibula were more likely to result in compartment syndrome than fractures of the middle or distal third (p = 0.03), as were fractures of the proximal third of the tibia (p = 0.01). No other demographic or injury parameters were associated with compartment syndrome. Ballistic fractures of the fibula and tibia are at increased risk for development of compartment syndrome over other ballistic fractures. We recommend increased vigilance when treating these injuries, particularly if the fracture is in the proximal aspect of the bone or is associated with vascular injury.

  4. Are bi-axial proximal sesamoid bone fractures in the British Thoroughbred racehorse a bone fatigue related fracture? A histological study.

    PubMed

    Kristoffersen, M; Hetzel, U; Parkin, T D H; Singer, E R

    2010-01-01

    To investigate whether microfractures and alterations in the trabecular bone area are associated with catastrophic bi-axial proximal sesamoid bone fractures (PSBF). Proximal sesamoid bones (PSB) from 10 racehorses with PSBF and from 10 control racehorses without musculoskeletal injury were examined using the bulk basic fuchsin method. Bone histomorphometric and microfracture analysis was performed, and cases and controls compared using two-sample t-test, paired t-test, and Mann-Whitney U test. There was no significant difference in the microfracture density and the trabecular bone area between bones from case and control horses, and between fractured and non-fractured bones in case horses. Microfracture density was low in the areas of the PSB examined. Microfracture density was not significantly different between groups, indicating that propagation of micro-cracks is an unlikely predisposing pathologic alteration in PSBF in British racehorses. There was no significant difference in the bone surface area between groups, which one would expect if modelling, adaptation and an increase in bone density were associated with PSBF fracture in the case horses. Therefore, PSBF in the British racehorse does not appear to be associated with microfractures of the trabecular bone of the PSB. The PSB fractures might represent an acute monotonic fracture; however, the aetiology of the fractures remains unknown with additional research required.

  5. Outcomes, and factors affecting outcomes, following shoulder hemiarthroplasty for proximal humeral fracture repair.

    PubMed

    Liu, Jie; Li, Shao-Hua; Cai, Zheng-Dong; Lou, Lie-Ming; Wu, Xing; Zhu, Yu-Chang; Wu, Wei-Ping

    2011-09-01

    Hemiarthroplasty has been applied to treat proximal humeral fracture with variable outcomes. The purpose of this retrospective study was to assess factors affecting outcome in patients following hemiarthroplasty for proximal humeral fracture (PHF) repair. Patients with proximal humeral fractures treated over a 6-year period were included. Indications for hemiarthroplasty were severe three-part fractures associated with osteoporosis; four-part fractures with or without dislocation; splitting of the humeral head, or >45% collapse of the humeral head. Surgery outcome and postoperative complications were main outcome measures in this study. Thirty-three of 47 patients were included in the final analysis (mean age 64.3 years, range 43-82). Mean postoperative follow-up was 44.4 (range 36-57) months. Postoperative complications (shoulder dislocation, mild shoulder subluxation, heterotopic ossification) occurred in seven patients. Healing of the greater and lesser tubercles was abnormal or poor in 18 patients. These patients had significantly higher pain scores (4.0 ± 1.1 vs. 2.2 ± 1.1) and significantly lower capacities for active lifting (79.3 ± 9.6 vs. 121.7 ± 24.3), external rotation (20.7 ± 3.7 vs. 39.2 ± 10.3), and Neer scores (79.2 ± 5.7 vs. 90.6 ± 3.6) versus patients who exhibited complete healing (all P < 0.001). Patient age, type of surgical approach, and fracture type were not major influencers of outcome. In conclusion, the healing of the greater and lesser tubercles is the major determinant of outcome following hemiarthroplasty for PHF repair.

  6. Interpretation of hip fracture patterns using areal bone mineral density in the proximal femur.

    PubMed

    Hey, Hwee Weng Dennis; Sng, Weizhong Jonathan; Lim, Joel Louis Zongwei; Tan, Chuen Seng; Gan, Alfred Tau Liang; Ng, Jun Han Charles; Kagda, Fareed H Y

    2015-12-01

    Bone mineral density scans are currently interpreted based on an average score of the entire proximal femur. Improvements in technology now allow us to measure bone density in specific regions of the proximal femur. The study attempts to explain the pathophysiology of neck of femur (NOF) and intertrochanteric/basi-cervical (IT) fractures by correlating areal BMD (aBMD) scores with fracture patterns, and explore possible predictors for these fracture patterns. This is a single institution retrospective study on all patients who underwent hip surgeries from June 2010 to August 2012. A total of 106 patients (44 IT/basi-cervical, 62 NOF fractures) were studied. The data retrieved include patient characteristics and aBMD scores measured at different regions of the contralateral hip within 1 month of the injury. Demographic and clinical characteristic differences between IT and NOF fractures were analyzed using Fisher's Exact test and two-sample t test. Relationship between aBMD scores and fracture patterns was assessed using multivariable regression modeling. After adjusted multivariable analysis, T-Troc and T-inter scores were significantly lower in intertrochanteric/basi-cervical fractures compared to neck of femur fractures (P = 0.022 and P = 0.026, respectively). Both intertrochanteric/basi-cervical fractures (mean T.Tot -1.99) and neck of femur fractures (mean T.Tot -1.64) were not found to be associated with a mean T.tot less than -2.5. However, the mean aBMD scores were consistently less than -2.5 for both intertrochanteric/basi-cervical fractures and neck of femur fractures. Gender and calcium intake at the time of injury were associated with specific hip fracture patterns (P = 0.002 and P = 0.011, respectively). Hip fracture patterns following low energy trauma may be influenced by the pattern of reduced bone density in different areas of the hip. Intertrochanteric/basi-cervical fractures were associated with significantly lower T-Troc and T-Inter scores

  7. Proximal femoral bone loss and increased rate of fracture with a proximally hydroxyapatite-coated femoral component.

    PubMed

    Radl, R; Aigner, C; Hungerford, M; Pascher, A; Windhager, R

    2000-11-01

    We performed a retrospective analysis of the clinical and radiological outcomes of total hip replacement using an uncemented femoral component proximally coated with hydroxyapatite. Of 136 patients, 118 who had undergone 124 primary total hip replacements were available for study. Their mean age was 66.5 years (19 to 90) and the mean follow-up was 5.6 years (4.25 to 7.25). At the final follow-up the mean Harris hip score was 92 (47.7 to 100). Periprosthetic femoral fractures, which occurred in seven patients (5.6%), were treated by osteosynthesis in six and conservatively in one. We had to revise five femoral components, one because of aseptic loosening, one because of septic loosening and three because of periprosthetic fracture. At the final follow-up there were definite signs of aseptic loosening in two patients. Radiologically, proximal femoral bone loss in Gruen zones I and VI was evident in 96.8% of hips, while bone hypertrophy in zones III and V was seen in 64.7%. In 24 hips (20.2%) the mean subsidence of the stem was 3.7 mm which occurred within the first 12 postoperative weeks. This indicated poor initial stability, which might have been aggravated by early weight-bearing. The high rate of failure in our study suggests that proximal femoral bone loss affects the long-term survival of the replacement.

  8. Prediction of local proximal tibial subchondral bone structural stiffness using subject-specific finite element modeling: Effect of selected density-modulus relationship.

    PubMed

    Nazemi, S Majid; Amini, Morteza; Kontulainen, Saija A; Milner, Jaques S; Holdsworth, David W; Masri, Bassam A; Wilson, David R; Johnston, James D

    2015-08-01

    Quantitative computed tomography based subject-specific finite element modeling has potential to clarify the role of subchondral bone alterations in knee osteoarthritis initiation, progression, and pain initiation. Calculation of bone elastic moduli from image data is a basic step when constructing finite element models. However, different relationships between elastic moduli and imaged density (known as density-modulus relationships) have been reported in the literature. The objective of this study was to apply seven different trabecular-specific and two cortical-specific density-modulus relationships from the literature to finite element models of proximal tibia subchondral bone, and identify the relationship(s) that best predicted experimentally measured local subchondral structural stiffness with highest explained variance and least error. Thirteen proximal tibial compartments were imaged via quantitative computed tomography. Imaged bone mineral density was converted to elastic moduli using published density-modulus relationships and mapped to corresponding finite element models. Proximal tibial structural stiffness values were compared to experimentally measured stiffness values from in-situ macro-indentation testing directly on the subchondral bone surface (47 indentation points). Regression lines between experimentally measured and finite element calculated stiffness had R(2) values ranging from 0.56 to 0.77. Normalized root mean squared error varied from 16.6% to 337.6%. Of the 21 evaluated density-modulus relationships in this study, Goulet combined with Snyder and Schneider or Rho appeared most appropriate for finite element modeling of local subchondral bone structural stiffness. Though, further studies are needed to optimize density-modulus relationships and improve finite element estimates of local subchondral bone structural stiffness. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Radial and tibial fracture repair with external skeletal fixation. Effects of fracture type, reduction, and complications on healing.

    PubMed

    Johnson, A L; Kneller, S K; Weigel, R M

    1989-01-01

    Twenty-eight consecutive fractures of the canine radius and tibia were treated with external skeletal fixation as the primary method of stabilization. The time of fixation removal (T1) and the time to unsupported weight-bearing (T2) were correlated with: (1) bone involved; (2) communication of the fracture with the external environment; (3) severity of the fracture; (4) proximity of the fracture to the nutrient artery; (5) method of reduction; (6) diaphyseal displacement after reduction; and (7) gap between cortical fragments after reduction. The Kruskal-Wallis one-way analysis of variance was used to test the correlation with p less than .05 set as the criterion for significance. The median T1 was 10 weeks and the median T2 was 11 weeks. None of the variables correlated significantly with either of the healing times; however, there was a strong trend toward longer healing times associated with open fractures and shorter healing times associated with closed reduction. Periosteal and endosteal callus uniting the fragments were observed radiographically in comminuted fractures, with primary bone union observed in six fractures in which anatomic reduction was achieved. Complications observed in the treatment of these fractures included: bone lysis around pins (27 fractures), pin track drainage (27 fractures), pin track hemorrhage (1 fracture), periosteal reaction around pins (27 fractures), radiographic signs consistent with osteomyelitis (12 fractures), degenerative joint disease (2 dogs), and nonunion (1 fracture). Valgus or rotational malalignment resulted in 16 malunions of fractures. One external fixation device was replaced and four loose pins were removed before the fractures healed. One dog was treated with antibiotics during the postoperative period because clinical signs of osteomyelitis appeared.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. A comparative study of intramedullary interlocking nailing and minimally invasive plate osteosynthesis in extra articular distal tibial fractures.

    PubMed

    Daolagupu, Arup K; Mudgal, Ashwani; Agarwala, Vikash; Dutta, Kaushik K

    2017-01-01

    Extraarticular distal tibial fractures are among the most challenging fractures encountered by an orthopedician for treatment because of its subcutaneous location, poor blood supply and decreased muscular cover anteriorly, complications such as delayed union, nonunion, wound infection, and wound dehiscence are often seen as a great challenge to the surgeon. Minimally invasive plate osteosynthesis (MIPO) and intramedullary interlocking nail (IMLN) are two well-accepted and effective methods, but each has been historically related to complications. This study compares clinical and radiological outcome in extraarticular distal tibia fractures treated by intramedullary interlocking nail (IMLN) and minimally invasive plate osteosynthesis (MIPO). 42 patients included in this study, 21 underwent IMLN and 21 were treated with MIPO who met the inclusion criteria and operated between June 2014 and May 2015. Patients were followed up for clinical and radiological evaluation. In IMLN group, average union time was 18.26 weeks compared to 21.70 weeks in plating group which was significant ( P < 0.0001). Average time required for partial and full weight bearing in the nailing group was 4.95 weeks and 10.09 weeks respectively which was significantly less ( P < 0.0001) as compared to 6.90 weeks and 13.38 weeks in the plating group. Lesser complications in terms of implant irritation, ankle stiffness, and infection, were seen in interlocking group as compared to plating group. Average functional outcome according to American Orthopedic Foot and Ankle Society score was measured which came out to be 96.67. IMLN group was associated with lesser duration of surgery, earlier weight bearing and union rate, lesser incidence of infection and implant irritation which makes it a preferable choice for fixation of extra-articular distal tibial fractures. However, larger randomized controlled trials are required for confirming the results.

  11. Anatomic tibial component design can increase tibial coverage and rotational alignment accuracy: a comparison of six contemporary designs.

    PubMed

    Dai, Yifei; Scuderi, Giles R; Bischoff, Jeffrey E; Bertin, Kim; Tarabichi, Samih; Rajgopal, Ashok

    2014-12-01

    The aim of this study was to comprehensively evaluate contemporary tibial component designs against global tibial anatomy. We hypothesized that anatomically designed tibial components offer increased morphological fit to the resected proximal tibia with increased alignment accuracy compared to symmetric and asymmetric designs. Using a multi-ethnic bone dataset, six contemporary tibial component designs were investigated, including anatomic, asymmetric, and symmetric design types. Investigations included (1) measurement of component conformity to the resected tibia using a comprehensive set of size and shape metrics; (2) assessment of component coverage on the resected tibia while ensuring clinically acceptable levels of rotation and overhang; and (3) evaluation of the incidence and severity of component downsizing due to adherence to rotational alignment and overhang requirements, and the associated compromise in tibial coverage. Differences in coverage were statistically compared across designs and ethnicities, as well as between placements with or without enforcement of proper rotational alignment. Compared to non-anatomic designs investigated, the anatomic design exhibited better conformity to resected tibial morphology in size and shape, higher tibial coverage (92% compared to 85-87%), more cortical support (posteromedial region), lower incidence of downsizing (3% compared to 39-60%), and less compromise of tibial coverage (0.5% compared to 4-6%) when enforcing proper rotational alignment. The anatomic design demonstrated meaningful increase in tibial coverage with accurate rotational alignment compared to symmetric and asymmetric designs, suggesting its potential for less intra-operative compromises and improved performance. III.

  12. Clinical comparison between open plating and minimally invasive plate osteosynthesis for displaced proximal humeral fractures: A prospective randomized controlled trial.

    PubMed

    Sohn, Hoon-Sang; Jeon, Yoon Sang; Lee, JuHan; Shin, Sang-Jin

    2017-06-01

    Recently, minimally invasive plate osteosynthesis (MIPO) has been widely used for the treatment of proximal humeral fractures. However, there is concern about whether the MIPO in comminuted proximal humeral fractures is also comparable to open plating. The purpose of this study was to compare the clinical and radiographic outcomes of open plating and MIPO for acute displaced proximal humeral fractures. In this prospective, randomized controlled study, 107 patients who had an acute proximal humeral fracture were randomized to either the open plating or MIPO techniques. Forty-five patients treated with open plating and 45 with the MIPO technique who were followed up at least 1year were evaluated. Shoulder functional assessment, operating time, several radiographic parameters, and complications were evaluated at final follow-up. The mean follow-up period was 15.0 months in the open plating and 14.3 months in the MIPO technique. There were no statistically significant differences in functional assessment scores and radiographic parameters between the two groups. High complications rates were found in 4-part fracture in both surgical methods The average operation time in the MIPO group were significantly lower compared to the open plating group (p<0.05). This study showed MIPO in proximal humerus fractures had similar clinical and radiographic outcomes compared to the open plating. However, the MIPO technique in proximal humerus fracture provided significantly shorter operation time than the open plating. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. The effect of retained intramedullary nails on tibial bone mineral density.

    PubMed

    Allen, J C; Lindsey, R W; Hipp, J A; Gugala, Z; Rianon, N; LeBlanc, A

    2008-07-01

    Intramedullary nailing has become a standard treatment for adult tibial shaft fractures. Retained intramedullary nails have been associated with stress shielding, although their long-term effect on decreasing tibial bone mineral density is currently unclear. The purpose of this study was to determine if retained tibial intramedullary nails decrease tibial mineral density in patients with successfully treated fractures. Patients treated with statically locked intramedullary nails for isolated, unilateral tibia shaft fractures were studied. Inclusion required that fracture had healed radiographically and that the patient returned to the pre-injury activity level. Data on patient demographic, fracture type, surgical technique, implant, and post-operative functional status were tabulated. Dual energy X-ray absorptiometry was used to measure bone mineral density in selected regions of the affected tibia and the contralateral intact tibia. Image reconstruction software was employed to ensure symmetry of the studied regions. Twenty patients (mean age 43; range 22-77 years) were studied at a mean of 29 months (range 5-60 months) following intramedullary nailing. There was statistically significant reduction of mean bone mineral density in tibiae with retained intramedullary nails (1.02 g/cm(2) versus 1.06 g/cm(2); P=0.04). A significantly greater decrease in bone mineral density was detected in the reamed versus non-reamed tibiae (-7% versus +6%, respectively; P<0.05). The present study demonstrates a small, but statistically significant overall bone mineral density decrease in healed tibiae with retained nails. Intramedullary reaming appears to be a factor potentiating the reduction of tibia bone mineral density in long-term nail retention.

  14. Biomechanical characterisation of osteosyntheses for proximal femur fractures: helical blade versus screw.

    PubMed

    Al-Munajjed, Amir A; Hammer, Joachim; Mayr, Edgar; Nerlich, Michael; Lenich, Andreas

    2008-01-01

    Proximal femur fractures are of main concern for elderly and especially osteoporotic patients. Despite advanced implant modifications and surgical techniques, serious mechanical complication rates between 4-18% are found in conventional osteosyntheses of proximal femur fractures. Clinical complications such as the rotation of the femoral head and the cut-out phenomenon of the fracture fixation bolt are often diagnosed during post-operative treatments. Therefore, efforts in new intramedulary techniques focus on the load bearing characteristics of the implant by developing new geometries to improve the implant-tissue interface. The objective of this investigation was to analyse the osteosynthesis/femur head interaction of two commonly used osteosyntheses, one with a helical blade and the other one with a screw design under different loading conditions. For the comparative investigation the helical blade of the Proximal Femur Nail Antirotation was investigated versus the screw system of the Dynamic Hip Screw. After implantation in a femoral head the loads for rotational overwinding of the implants were analysed. Pull-out forces with suppressed rotation were investigated with analysis of the influence of the previous overwinding. All investigations were performed on human femoral heads taken of patients with average age of 70.3+/-11.8. The bone mineral densities of the human specimens were detected by QCT-scans (average BMD: 338.9+/- 61.3$\\frac[\\mathit[mg

  15. Complications in proximal humeral fractures.

    PubMed

    Calori, Giorgio Maria; Colombo, Massimiliano; Bucci, Miguel Simon; Fadigati, Piero; Colombo, Alessandra Ines Maria; Mazzola, Simone; Cefalo, Vittorio; Mazza, Emilio

    2016-10-01

    Necrosis of the humeral head, infections and non-unions are among the most dangerous and difficult-to-treat complications of proximal humeral fractures. The aim of this work was to analyse in detail non-unions and post-traumatic bone defects and to suggest an algorithm of care. Treatment options are based not only on the radiological frame, but also according to a detailed analysis of the patient, who is classified using a risk factor analysis. This method enables the surgeon to choose the most suitable treatment for the patient, thereby facilitating return of function in the shortest possible time. The treatment of such serious complications requires the surgeon to be knowledgeable about the following possible solutions: increased mechanical stability; biological stimulation; and reconstructive techniques in two steps, with application of biotechnologies and prosthetic substitution. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Management of simple (types A and B) closed tibial shaft fractures using percutaneous lag-screw fixation and Ilizarov external fixation in adults.

    PubMed

    El-Sayed, Mohamed; Atef, Ashraf

    2012-10-01

    Although intramedullary fixation of closed simple (type A or B) diaphyseal tibial fractures in adults is well tolerated by patients, providing lower morbidity rates and better mobility, it is associated with some complications. This study evaluated the results of managing these fractures using percutaneous minimal internal fixation using one or more lag screws, and Ilizarov external fixation. This method was tested to evaluate its efficacy in immediate weight bearing, fracture healing and prevention of any post-immobilisation stiffness of the ankle and knee joints. This randomised blinded study was performed at a referral, academically supervised, level III trauma centre. Three hundred and twenty-four of the initial 351 patients completed this study and were followed up for a minimum of 12 (12-88) months. Patient ages ranged from 20 to 51 years, with a mean of 39 years. Ankle and knee movements and full weight bearing were encouraged immediately postoperatively. Solid union was assessed clinically and radiographically. Active and passive ankle and knee ranges of motion were measured and compared with the normal side using the Wilcoxon signed rank test for matched pairs. Subjective Olerud and Molander Ankle Score was used to detect any ankle joint symptoms at the final follow-up. No patient showed delayed or nonunion. All fractures healed within 95-129 days. Based on final clinical and radiographic outcomes, this technique proves to be adequate for managing simple diaphyseal tibial fractures. On the other hand, it is relatively expensive, technically demanding, necessitates exposure to radiation and patients are expected to be frame friendly.

  17. The location of the tibial accelerometer does influence impact acceleration parameters during running.

    PubMed

    Lucas-Cuevas, Angel Gabriel; Encarnación-Martínez, Alberto; Camacho-García, Andrés; Llana-Belloch, Salvador; Pérez-Soriano, Pedro

    2017-09-01

    Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s -1 with three accelerometers attached with double-sided tape and tightened to the participants' tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made.

  18. Allograft-prosthesis composites after bone tumor resection at the proximal tibia.

    PubMed

    Biau, David Jean; Dumaine, Valérie; Babinet, Antoine; Tomeno, Bernard; Anract, Philippe

    2007-03-01

    The survival of irradiated allograft-prosthesis composites at the proximal tibia is mostly unknown. However, allograft-prosthesis composites have proved beneficial at other reconstruction sites. We presumed allograft-prosthesis composites at the proximal tibia would improve survival and facilitate reattachment of the extensor mechanism compared with that of conventional (megaprostheses) reconstructions. We retrospectively reviewed 26 patients who underwent resection of proximal tibia tumors followed by reconstruction with allo-graft-prosthesis composites. Patients received Guepar massive custom-made fully constrained prostheses. Allografts were sterilized with gamma radiation, and the stems were cemented into the allograft and host bone. The minimum followup was 6 months (median, 128 months; range, 6-195 months). Fourteen patients had one or more components removed. The median allograft-prosthesis composite survival was 102 months (95% confidence interval, 64.2-infinity). Of the 26 allografts, seven fractured, six showed signs of partial resorption, and six had infections develop. Seven allografts showed signs of fusion with the host bone. Six extensor mechanism reconstructions failed. Allograft-prosthesis composites sterilized by gamma radiation yielded poor results for proximal tibial reconstruction as complications and failures were common. We do not recommend irradiated allograft-prosthesis composites for proximal tibia reconstruction.

  19. Influence of restorative material and proximal cavity design on the fracture resistance of MOD inlay restoration.

    PubMed

    Liu, Xiaozhou; Fok, Alex; Li, Haiyan

    2014-03-01

    This study aimed to evaluate the effects of the restorative material and cavity design on the facture resistance of inlay restorations under a compressive load using acoustic emission (AE) measurement. Two restorative materials, a composite resin (MZ100, 3M ESPE) and a ceramic (IPS Empress CAD, Ivoclar Vivadent), and two cavity designs, non-proximal box and proximal box, were studied. Thirty-two extracted human third molars were selected and divided into 4 groups. The restorative materials and cavity designs used for the four groups were: (1) composite and non-proximal box; (2) ceramic and non-proximal box; (3) composite and proximal box; (4) ceramic and proximal box. The restored molars were loaded in a MTS machine via a loading head of diameter 10mm. The rate of loading was 0.1mm/min. During loading, an AE system was used to monitor the debonding and fracture of the specimens. The load corresponding to the first AE event, the final maximum load sustained, as well as the total number of AE events recorded were used to evaluate the fracture resistance of the restored teeth. For the initial fracture load, Group 2 (236.15N)Group 2 (1685)>Group 3 (239)>Group 1 (221). The differences from pairwise comparisons in the initial fracture load and final load were mostly insignificant statistically (p>0.05), the only exception being that between Groups 2 and 3 in the initial fracture load (p=0.039). For the total number of AE events, statistically significant differences (p<0.05) were found between all group pairs that involved different materials, with the composite groups giving much fewer AE events than the ceramic groups. Conversely, no statistically significant difference in the AE results was found between groups with the same material

  20. Robust QCT/FEA Models of Proximal Femur Stiffness and Fracture Load During a Sideways Fall on the Hip

    PubMed Central

    Dragomir-Daescu, Dan; Buijs, Jorn Op Den; McEligot, Sean; Dai, Yifei; Entwistle, Rachel C.; Salas, Christina; Melton, L. Joseph; Bennet, Kevin E.; Khosla, Sundeep; Amin, Shreyasee

    2013-01-01

    Clinical implementation of quantitative computed tomography-based finite element analysis (QCT/FEA) of proximal femur stiffness and strength to assess the likelihood of proximal femur (hip) fractures requires a unified modeling procedure, consistency in predicting bone mechanical properties, and validation with realistic test data that represent typical hip fractures, specifically, a sideways fall on the hip. We, therefore, used two sets (n = 9, each) of cadaveric femora with bone densities varying from normal to osteoporotic to build, refine, and validate a new class of QCT/FEA models for hip fracture under loading conditions that simulate a sideways fall on the hip. Convergence requirements of finite element models of the first set of femora led to the creation of a new meshing strategy and a robust process to model proximal femur geometry and material properties from QCT images. We used a second set of femora to cross-validate the model parameters derived from the first set. Refined models were validated experimentally by fracturing femora using specially designed fixtures, load cells, and high speed video capture. CT image reconstructions of fractured femora were created to classify the fractures. The predicted stiffness (cross-validation R2 = 0.87), fracture load (cross-validation R2 = 0.85), and fracture patterns (83% agreement) correlated well with experimental data. PMID:21052839

  1. WhatsApp Messenger is useful and reproducible in the assessment of tibial plateau fractures: inter- and intra-observer agreement study.

    PubMed

    Giordano, Vincenzo; Koch, Hilton Augusto; Mendes, Carlos Henrique; Bergamin, André; de Souza, Felipe Serrão; do Amaral, Ney Pecegueiro

    2015-02-01

    The aim of this study was to evaluate the inter- and intra-observer agreement in the initial diagnosis and classification by means of plain radiographs and CT scans of tibial plateau fractures photographed and sent via WhatsApp Messenger. The increasing popularity of smartphones has driven the development of technology for data transmission and imaging and generated a growing interest in the use of these devices as diagnostic tools. The emergence of WhatsApp Messenger technology, which is available for various platforms used by smartphones, has led to an improvement in the quality and resolution of images sent and received. The images (plain radiographs and CT scans) were obtained from 13 cases of tibial plateau fractures using the iPhone 5 (Apple Inc., Cupertino, CA, USA) and were sent to six observers via the WhatsApp Messenger application. The observers were asked to determine the standard deviation and type of injury, the classification according to the Schatzker and the Luo classifications schemes, and whether the CT scan changed the classification. The six observers independently assessed the images on two separate occasions, 15 days apart. The inter- and intra-observer agreement for both periods of the study ranged from excellent to perfect (0.75<κ<1.0) across all survey questions. When asked if the inclusion of the CT images would change their final X-ray classification (Schatzker or Luo), the inter- and intra-observer agreement was perfect (k=1) on both assessment occasions. We found an excellent inter- and intra-observer agreement in the imaging assessment of tibial plateau fractures sent via WhatsApp Messenger. The authors now propose the systematic use of the application to facilitate faster documentation and obtaining the opinion of an experienced consultant when not on call. Finally, we think the use of the WhatsApp Messenger as an adjuvant tool could be broadened to other clinical centres to assess its viability in other skeletal and non

  2. A review of current surgical practice in the operative treatment of proximal humeral fractures

    PubMed Central

    Jones, L. D.; Palmer, A. J. R.; Macnair, R. D.; Brewer, P. E.; Jayadev, C.; Wheelton, A. N.; Ball, D. E. J.; Nandra, R. S.; Aujla, R. S.; Sykes, A. E.; Carr, A. J.

    2016-01-01

    Objectives The PROximal Fracture of the Humerus: Evaluation by Randomisation (PROFHER) trial has recently demonstrated that surgery is non-superior to non-operative treatment in the management of displaced proximal humeral fractures. The objective of this study was to assess current surgical practice in the context of the PROFHER trial in terms of patient demographics, injury characteristics and the nature of the surgical treatment. Methods A total of ten consecutive patients undergoing surgery for the treatment of a proximal humeral fracture from each of 11 United Kingdom hospitals were retrospectively identified over a 15 month period between January 2014 and March 2015. Data gathered for the 110 patients included patient demographics, injury characteristics, mode of surgical fixation, the grade of operating surgeon and the cost of the surgical implants. Results A majority of the patients were female (66%, 73 of 110). The mean patient age was 62 years (range 18 to 89). A majority of patients met the inclusion criteria for the PROFHER trial (75%, 83 of 110). Plate fixation was the most common mode of surgery (68%, 75 patients), followed by intramedullary fixation (12%, 13 patients), reverse shoulder arthroplasty (10%, 11 patients) and hemiarthroplasty (7%, eight patients). The consultant was either the primary operating surgeon or supervising the operating surgeon in a large majority of cases (91%, 100 patients). Implant costs for plate fixation were significantly less than both hemiarthroplasty (p < 0.05) and reverse shoulder arthroplasty (p < 0.0001). Implant costs for intramedullary fixation were significantly less than plate fixation (p < 0.01), hemiarthroplasty (p < 0.0001) and reverse shoulder arthroplasty (p < 0.0001). Conclusions Our study has shown that the majority of a representative sample of patients currently undergoing surgical treatment for a proximal humeral fracture in these United Kingdom centres met the inclusion criteria for the PROFHER trial

  3. Outcomes assessment in the SPRINT multicenter tibial fracture trial: Adjudication committee size has trivial effect on trial results.

    PubMed

    Simunovic, Nicole; Walter, Stephen; Devereaux, P J; Sprague, Sheila; Guyatt, Gordon H; Schemitsch, Emil; Tornetta, Paul; Sanders, David; Swiontkowski, Marc; Bhandari, Mohit

    2011-09-01

    To evaluate how the size of an outcome adjudication committee, and the potential for dominance among its members, potentially impacts a trial's results. We conducted a retrospective analysis of data from the six-member adjudication committee in the Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT) Trial. We modeled the adjudication process, predicted the results and costs if smaller committees had been used, and tested for the presence of a dominant adjudicator. Use of smaller committee sizes (one to five members) would have had little impact on the final study results, although one analysis suggested that the benefit in reduction of reoperations with reamed nails in closed tibial fractures would have lost significance if committee sizes of three or less were used. We identified a significant difference between adjudicators in the number of times their original minority decisions became the final consensus decision (χ(2)=9.67, P=0.046), suggesting that dominant adjudicators were present. However, their impact on the final study results was trivial. Reducing the number of adjudicators from six to four would have led to little change in the final SPRINT study results irrespective of the significance of the original trial results, demonstrating the potential for savings in trial resources. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. [Proximal femoral fractures in the elderly: pathogenesis, sequelae, interventions].

    PubMed

    Runge, M; Schacht, E

    1999-08-01

    Hip fractures are a health problem of paramount importance for the individual and society. They are associated with a sharp increase of the incidence of immobility, dependency, nursing home placement, and death. In Germany, more than 100,000 elderly suffer a hip fracture every year. 90% of fractures of the proximal femur result from a fall with an impact near the hip. The kinetic energy of a fall from standing height without successful protective reactions is far above the fracture threshold of a femur in a man aged 70 and older, regardless of osteoporosis and sex. Therefore, propensity to fall and mechanisms of falling are more important in the pathogenesis of hip fracture than bone mineral density alone. The combination of age-associated gait and balance disorders, which increase the probability of falls, and age-related decreasing strength of the femur is responsible for the high incidence of hip fractures. Besides the interventions to reduce the fall frequency it is possible to decrease the number of hip fractures by a passive protection of the trochanter. An energy-shunting protector (crash helmet-like, hip padding) has been developed by Lauritzen and Lund (safehip). The protector consists of two stiff shells, sewn into special undergarment. The shells disperse the impact away from the trochanter to soft tissue, and increase the area of contact. A controlled study among nursing home residents has demonstrated a relative risk of hip fracture of 0.44 (95% CC 0.21 to 0.94) in the intervention group, i.e., the protector has reduced the number of hip fractures by more than a half. No hip fracture has happened during use of the protector. Using the protector can improve self-confidence and diminish self-restraint of physical activity, which is not rarely caused by fear of falling. Further investigations of compliance are necessary.

  5. Prevalence of knee stiffness after arthroscopic bone suture fixation of tibial spine avulsion fractures in adults.

    PubMed

    Thaunat, M; Barbosa, N C; Gardon, R; Tuteja, S; Chatellard, R; Fayard, J-M; Sonnery-Cottet, B

    2016-09-01

    Tibial spine avulsion fractures (TSAFs) occur chiefly in adolescents. Few published data are available on outcomes after arthroscopic surgical treatment of TSAFs in adults. To evaluate outcomes of consecutive patients with TSAFs managed by arthroscopic bone suture followed by a standardised non-aggressive rehabilitation programme. Arthroscopic bone suture followed by non-aggressive rehabilitation therapy reliably produces satisfactory outcomes in adults with TSAF. Thirteen adults were included. Outcomes were evaluated based on the Tegner score, International Knee Documentation Committee (IKDC) score, anterior-posterior knee laxity, passive and active motion ranges, and radiological appearance. After a mean follow-up of 41±27months (12-94months), all 13 patients had healed fractures without secondary displacement. No patient had knee instability. Post-operative stiffness was noted in 5 patients (2 with complex regional pain syndrome and 3 with extension lag), 1 of whom required surgical release. The mean IKDC score was 91.3±11.7. The mean Tegner score was 5.46±1.37 compared to 6.38±0.70 before surgery. Mean tibial translation (measured using the Rolimeter) was 1.09±1.22mm, compared to 5.9±1.85mm before surgery. The outcomes reported here support the reliability of arthroscopic bone suture for TSAF fixation. Nevertheless, a substantial proportion of patients experienced post-operative stiffness, whose contributory factors may include stunning of the quadriceps due to the short time from injury to surgery and the use of a gentle rehabilitation programme. IV, retrospective study of treatment outcomes. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Do Treatment Policies for Proximal Humerus Fractures Differ among Three Nordic Countries and Estonia? Results of a Survey Study.

    PubMed

    Launonen, A P; Lepola, V; Laitinen, M; Mattila, V M

    2016-09-01

    Proximal humerus fractures are common fragility injuries. The incidence of these fractures has been estimated to be 82-105 per 105 person-years. Treatment of this fracture, especially in the elderly, is controversial. Our study group published a systematic review of the available literature and concluded that non-operative methods are favored over operative methods in three- and four-part fractures. The aim of this multinational study was to compare treatment policies for proximal humerus fractures among the Nordic countries and Estonia. The study was conducted as a questionnaire-based survey, using the Internet-based program, Webropol(®) (webropol.com). The questionnaire link was sent to the surgeons responsible for treating proximal humerus fractures in major public hospitals in Estonia, Finland, Norway, and Sweden. Questionnaire included questions regarding the responder's hospital, patient characteristics, and examinations taken before decision making. Clinical part included eight example patient cases with treatment options. Of the 77 recipients of the questionnaire, 59 responded; consequently, the response rate was 77%. Based on the eight presented displaced fracture examples, in both Estonia and Norway and in Finland, 41% and 38%, respectively, preferred surgical treatment with locking plate. In Sweden, the percentage was 28%. The pre- and post-operative protocols showed a similarity in all participant countries. Our survey revealed a remarkable uniformity in the current practice of operative treatments and rehabilitation for proximal humerus fractures in the participant countries. © The Finnish Surgical Society 2016.

  7. Analysis of foot structure in athletes sustaining proximal fifth metatarsal stress fracture.

    PubMed

    Hetsroni, Iftach; Nyska, Meir; Ben-Sira, David; Mann, Gideon; Segal, Ofer; Maoz, Guy; Ayalon, Moshe

    2010-03-01

    In the past, several studies provided anecdotal descriptions of high-arched feet in individuals sustaining proximal fifth metatarsal stress fractures. This relationship has never been supported by scientific evidence. Our objective was to examine whether athletes who sustained this injury had an exceptional static foot structure or dynamic loading pattern. Ten injured professional soccer players who regained full professional activity following a unilateral proximal fifth metatarsal stress fracture and ten control soccer players were examined. Independent variables included static evaluation of foot and arch structure, followed by dynamic plantar foot pressure evaluation. Each variable was compared between injured, contra-lateral uninjured, and control feet. Static measurements of foot and arch structure did not reveal differences among the groups. However, plantar pressure evaluation revealed relative unloading of the fourth metatarsal in injured and uninjured limbs of injured athletes compared with control, while the fifth metatarsal revealed pressure reduction only in the injured limbs of injured athletes. Athletes who sustained proximal fifth metatarsal stress fracture were not characterized by an exceptional static foot structure. Dynamically, lateral metatarsal unloading during stance may either play a role in the pathogenesis of the injury, or alternately represent an adaptive process. Footwear fabrication for previously injured athletes should not categorically address cushioning properties designed for high-arch feet, but rather focus on individual dynamic evaluation of forefoot loading, with less attention applied to static foot and arch characteristics.

  8. EPIDEMIOLOGICAL CHARACTERISTICS AND CAUSES OF PROXIMAL FEMORAL FRACTURES AMONG THE ELDERLY

    PubMed Central

    Neto, José Soares Hungria; Dias, Caio Roncon; de Almeida, José Daniel Bula

    2015-01-01

    Objective: The social and economic cost of proximal femoral fractures is high, due the morbidity and mortality relating to the fracture itself, among other factors. Despite the importance of this issue, studies on this topic are still scarce in Brazil. This was a retrospective, observational and cross-sectional (ecological) study with the aims of outlining an epidemiological profile for proximal femoral fractures among the elderly and analyzing the causes of these fractures and the physical characteristics of patients admitted to a single university hospital in São Paulo. Methods: This was a study on medical records over a one-year period, with group comparisons using the chi-square test; p > 0.05 was considered significant. Results: Ninety-four individuals were evaluated: predominantly female (2:1); 81-85 years of age; body mass index within normal limits; white and Asian patients (p > 0.05). The vast majority of the fractures occurred through low-energy trauma and inside the patients’ homes (p > 0.05). After excluding the trauma resulting from high-energy events, over 39% occurred as the patients were moving from sitting to standing up or were using stairs, and approximately 40% occurred while they were standing still or walking. A greater number of cases corresponded to the cold seasons of the year (p > 0.05); Conclusion: Most injuries occurred inside the patients’ own homes and had low-energy causes. Thus, some accidents might be avoided through simple low-cost measures that guide the elderly regarding situations of risk, which would bring major quality-of-life benefits and significant decreases in morbidity, mortality and the socioeconomic costs of this increasingly frequent problem. PMID:27027070

  9. Biomechanical Factors in Tibial Stress Fracture

    DTIC Science & Technology

    2001-08-01

    Relationship between Loading Rates and Tibial Accelerometry in Forefoot Strike Runners. Presented at the Annual American Society of Biomechanics Mtg...of the APTA, Seattle, WA, 2/99. McClay, IS, Williams, DS, and Manal, KT. Lower Extremity Mechanics of Runners with a Converted Forefoot Strike ...Management, Inc, 1998-1999 The Effect of Different Orthotic Devices on Lower Extremity Mechanics of Rearfoot and Forefoot Strikers, $3,500. Foot Management

  10. A new surgical technique for traumatic dislocation of posterior tibial tendon with avulsion fracture of medial malleolus.

    PubMed

    Jeong, Soon-Taek; Hwang, Sun-Chul; Kim, Dong-Hee; Nam, Dae-Cheol

    2015-01-01

    We introduce a case of traumatic dislocation of the posterior tibial tendon with avulsion fracture of the medial malleolus in a 52-year-old female patient who was treated surgically with periosteal flap and suture anchor fixation. Based in the posteromedial ridge of the distal tibia, a quadrilateral periosteal flap was created and folded over the tendon, followed by fixation on the lateral aspect of the groove by use of multiple suture anchors. Clinical and radiological findings 25 months postoperatively showed well-preserved function of the ankle joint with stable tendon gliding.

  11. Tibial anatomy in normal small breed dogs including anisometry of various extracapsular stabilizing suture attachment sites.

    PubMed

    Witte, P G

    2015-01-01

    To investigate proximal tibial anatomy and its influence on anisometry of extracapsular stabilizing sutures in small dog breeds. Mediolateral radiographs of the femora, stifles, and tibiae of 12 small breed dogs were acquired with the stifles positioned at various angles. Measurements taken included tibial plateau angle (TPA), diaphyseal: proximal tibial angle (DPA), patellar tendon angle (PTA), Z-angle, relative tibial tuberosity width (rTTW), and the distance between six combinations of two femoral and three tibial extra-capsular stabilizing suture (ECS) attachment sites. Theoretical strain through stifle range-of-motion was recorded. The TPA (32° ± 5.8°), DPA (10.2° ± 7.3°), PTA (103.7° ± 6.2°), and Z-angle (70.4° ± 9.0°) were positively correlated with one another (R >0.7), but none were correlated with rTTW (0.93 ± 0.10). The F2-T1 combination of ECS attachment sites had lowest strain for nine stifles. The shortest attachment site separation was at a stifle flexion of 50° for nine stifles. Proximal tibial anatomy measurements could not predict optimal attachment site combination, optimal stifle angle for suture placement, or ECS strain. There is individual variation in the optimal attachment site combination and stifle angle for suture placement, which may influence consistency of outcomes with ECS.

  12. Differential diagnosis of trampoline fracture from osteomyelitis by bone scan with pinhole collimator.

    PubMed

    Gauthé, Mathieu; Mestas, Danielle; Canavese, Federico; Samba, Antoine; Cachin, Florent

    2014-02-01

    A 2-year-old girl with recent history of trampoline fall presented to the A&E Department for complete functional impairment of the left lower extremity and fever. Blood examination revealed an inflammatory syndrome, while plain radiographs were normal. As magnetic resonance imaging was unavailable, a bone scintigraphy was performed. While standard acquisition found an intense uptake focused on the left proximal tibial metaphysis whose appearance was suggestive of acute hematogenous osteomyelitis, complementary acquisition with the pinhole collimator demonstrated that this abnormal uptake was clearly distinct from the cartilage growth plate. One month follow-up radiographs showed a fracture that confirmed the diagnosis of trampoline fracture.

  13. Proximal humeral fracture classification systems revisited.

    PubMed

    Majed, Addie; Macleod, Iain; Bull, Anthony M J; Zyto, Karol; Resch, Herbert; Hertel, Ralph; Reilly, Peter; Emery, Roger J H

    2011-10-01

    This study evaluated several classification systems and expert surgeons' anatomic understanding of these complex injuries based on a consecutive series of patients. We hypothesized that current proximal humeral fracture classification systems, regardless of imaging methods, are not sufficiently reliable to aid clinical management of these injuries. Complex fractures in 96 consecutive patients were investigated by generation of rapid sequence prototyping models from computed tomography Digital Imaging and Communications in Medicine (DICOM) imaging data. Four independent senior observers were asked to classify each model using 4 classification systems: Neer, AO, Codman-Hertel, and a prototype classification system by Resch. Interobserver and intraobserver κ coefficient values were calculated for the overall classification system and for selected classification items. The κ coefficient values for the interobserver reliability were 0.33 for Neer, 0.11 for AO, 0.44 for Codman-Hertel, and 0.15 for Resch. Interobserver reliability κ coefficient values were 0.32 for the number of fragments and 0.30 for the anatomic segment involved using the Neer system, 0.30 for the AO type (A, B, C), and 0.53, 0.48, and 0.08 for the Resch impaction/distraction, varus/valgus and flexion/extension subgroups, respectively. Three-part fractures showed low reliability for the Neer and AO systems. Currently available evidence suggests fracture classifications in use have poor intra- and inter-observer reliability despite the modality of imaging used thus making treating these injuries difficult as weak as affecting scientific research as well. This study was undertaken to evaluate the reliability of several systems using rapid sequence prototype models. Overall interobserver κ values represented slight to moderate agreement. The most reliable interobserver scores were found with the Codman-Hertel classification, followed by elements of Resch's trial system. The AO system had the lowest

  14. Stress fracture as a complication of autogenous bone graft harvest from the distal tibia.

    PubMed

    Chou, Loretta B; Mann, Roger A; Coughlin, Michael J; McPeake, William T; Mizel, Mark S

    2007-02-01

    Autogenous bone graft from the distal tibia provides cancellous bone graft for foot and ankle operations, and it has osteogenic and osteoconductive properties. The site is in close proximity to the foot and ankle, and published retrospective studies show low morbidity from the procedure. One-hundred autografts were obtained from the distal tibia between 2000 and 2003. In four cases the distal tibial bone graft harvest resulted in a stress fracture. There were three women and one man. The average time of diagnosis of the stress fracture from the operation was 1.8 months. All stress fractures healed with a short course (average 2.4 months) of cast immobilization. This study demonstrated that a stress fracture from the donor site of autogenous bone graft of the distal tibia occurs and can be successfully treated nonoperatively.

  15. Computed tomography for occult fractures of the proximal femur, pelvis, and sacrum in clinical practice: single institution, dual-site experience.

    PubMed

    Mandell, Jacob C; Weaver, Michael J; Khurana, Bharti

    2018-06-01

    The purpose of this study was to evaluate the diagnostic performance of CT for assessment of occult fractures of the proximal femur, pelvis, and sacrum. A retrospective review was performed on patients who received a CT of the hip or pelvis for suspected occult fracture after negative or equivocal radiographs performed within 24 h. The official radiology report was utilized for the determination of CT findings and calculation of sensitivity and specificity. Surgical reports, MRI reports, and clinical follow-up were used as the standard of reference. Sensitivity and specificity were calculated with 95% confidence intervals. Seventy-four patients received CT of the hip or pelvis for clinical concern for occult fracture after negative or equivocal radiographs. By the reference standard, a total of 40 fractures were present in 25/74 (33.8%) patients, including 35 conservatively treated fractures of the greater trochanter, pelvis, and sacrum, and 5 operatively treated proximal femoral fractures. A total of 14/74 (18.9%) of patients had an MRI within 1 day of CT. MRI identified an operatively treated femoral neck fracture not seen on CT and an operatively treated intertrochanteric fracture, which CT described as a greater trochanteric fracture. There were two false negative conservatively treated pelvic fractures not seen on CT but diagnosed on MRI. On a per-patient basis, CT had an overall sensitivity of 88% (22/25; 95% confidence intervals 69-97%), specificity of 98% (48/49; 95% confidence intervals 89-100%), and negative predictive value of 94%. For the five operative proximal femoral fractures, the sensitivity of CT was 60% (3/5; 95% confidence intervals 15-95%), specificity was 99% (68/69; 95% confidence intervals 92-100%), and negative predictive value was 97%. In the clinical setting of suspected occult fracture, the sensitivity of clinical CT reports for detection of any type of fracture of the proximal femur, pelvis, or sacrum was 88%. For the small number of

  16. Interventions for treating proximal humeral fractures in adults.

    PubMed

    Handoll, Helen H G; Ollivere, Benjamin J; Rollins, Katie E

    2012-12-12

    Fractures of the proximal humerus are common injuries. The management, including surgical intervention, of these fractures varies widely. This is an update of a Cochrane review first published in 2001 and last updated in 2010. To review the evidence supporting the various treatment and rehabilitation interventions for proximal humeral fractures. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE and other databases, and bibliographies of trial reports. The full search ended in January 2012. All randomised controlled trials pertinent to the management of proximal humeral fractures in adults were selected. Two people performed independent study selection, risk of bias assessment and data extraction. Only limited meta-analysis was performed. Twenty-three small randomised trials with a total of 1238 participants were included. Bias in these trials could not be ruled out. Additionally there is a need for caution in interpreting the results of these small trials, which generally do not provide sufficient evidence to conclude that any non-statistically significant finding is 'evidence of no effect'.Eight trials evaluated conservative treatment. One trial found an arm sling was generally more comfortable than a less commonly used body bandage. There was some evidence that 'immediate' physiotherapy compared with that delayed until after three weeks of immobilisation resulted in less pain and potentially better recovery in people with undisplaced or other stable fractures. Similarly, there was evidence that mobilisation at one week instead of three weeks alleviated short term pain without compromising long term outcome. Two trials provided some evidence that unsupervised patients could generally achieve a satisfactory outcome when given sufficient instruction for an adequate self-directed exercise programme.Six heterogeneous trials, involving a total of 270 participants with

  17. PATIENT-SPECIFIC FINITE ELEMENT ANALYSIS OF CHRONIC CONTACT STRESS EXPOSURE AFTER INTRA-ARTICULAR FRACTURE OF THE TIBIAL PLAFOND

    PubMed Central

    Li, Wendy; Anderson, Donald D.; Goldsworthy, Jane K.; Marsh, J. Lawrence; Brown, Thomas D.

    2008-01-01

    SUMMARY The role of altered contact mechanics in the pathogenesis of post-traumatic osteoarthritis (PTOA) following intra-articular fracture remains poorly understood. One proposed etiology is that residual incongruities lead to altered joint contact stresses that, over time, predispose to PTOA. Prevailing joint contact stresses following surgical fracture reduction were quantified in this study using patient-specific contact finite element (FE) analysis. FE models were created for 11 ankle pairs from tibial plafond fracture patients. Both (reduced) fractured ankles and their intact contralaterals were modeled. A sequence of 13 loading instances was used to simulate the stance phase of gait. Contact stresses were summed across loadings in the simulation, weighted by resident time in the gait cycle. This chronic exposure measure, a metric of degeneration propensity, was then compared between intact and fractured ankle pairs. Intact ankles had lower peak contact stress exposures that were more uniform, and centrally located. The series-average peak contact stress elevation for fractured ankles was 38% (p=0.0015; peak elevation was 82%). Fractured ankles had less area with low contact stress exposure than intacts, and a greater area with high exposure. Chronic contact stress overexposures (stresses exceeding a damage threshold) ranged from near zero to a high of 18 times the matched intact value. The patient-specific FE models utilized in this study represent substantial progress towards elucidating the relationship between altered contact stresses and the outcome of patients treated for intra-articular fractures. PMID:18404662

  18. Management of a type two avulsion fracture of the tibial intercondylar eminence in children: arthroscopic suture fixation versus conservative immobilization.

    PubMed

    Zhao, Chen; Bi, Qing; Bi, Mingguang

    2018-06-01

    Treatment of a type II tibial eminence avulsion fracture was controversial. The aim of this study was to compare the clinical outcomes of a modified arthroscopic suture fixation versus conservative immobilization in treatment of this type fracture in immature population. A total of 43 type II avulsion fractures of tibial intercondylar eminence in immature patients were retrospectively enrolled in the study. Twenty-two (13 males, 9 females) were treated with arthroscopic suture fixation and 21(12 males, 9 females) with conservative cast immobilization. Radiograph, Lachman test, anterior drawer test (ADT), International Knee Documentation Committee (IKDC) 2000 subjective score, and Lysholm score were used to evaluate clinical outcomes in follow-up. All 43 paediatric or adolescent patients with a mean of 11.3 years (range, 8-16 years) were followed up for a median period of 34.5 months (range, 24-46 months). Radiographic evaluation showed optimal reduction immediately after surgery and bone union within three months. At the final follow-up, no limitation of knee motion range was found in any children. Grade II laxity was found in one case from surgical group and six from conservation group, showing significant difference based on ADT (χ2 = 7.927, P = 0.005) and Lachman tests (χ2 = 9.546, P = 0.002). IKDC and Lysholm scores were significantly improved; however, there were significant differences in the IKDC score (91.7 ± 4.34 vs. 84.7 ± 6.11, t = 4.35, P < 0.001) and Lysholm score (93.4 ± 4.04 vs. 87.1 ± 5.24, t = 4.53, P < 0.001), and the improvement of IKDC value (40.2 ± 7.83 vs. 31.4 ± 8.4, t = 3.57, P = 0.001) and Lysholm value (43.8 ± 6.55 vs. 35.4 ± 5.97, t = 4.36, P < 0.001) between the surgical group and the nonsurgical group. In treatment of type II tibial eminence avulsion fracture, a modified, 8 shape suture fixation under arthroscopy showed superior clinical

  19. Body mass index as a prognostic factor for fracturing of the proximal extremity of the femur: a case–control study☆☆☆

    PubMed Central

    Pagani, Renato Cavanus; Kunz, Rodrigo Ernesto; Girardi, Ricardo; Guerra, Marcelo

    2014-01-01

    Objectives To compare the body mass index (BMI) of patients with fractures in the proximal extremity of the femur with the BMI of patients without any previous history of fractures. Methods We investigated patients of both sexes, aged 65 years or over, who were admitted to Hospital Independência, Hospital Beneficência Portuguesa or ULBRA University Hospital, between December 2007 and December 2010, with histories of low-energy trauma such as falling from a standing position. These individuals were compared with patients of the same age but without any history of fracturing of the proximal extremity of the femur (n = 89), who were attended at the geriatrics outpatient clinic of the Sociedade Porto-Alegrense de Auxílio aos Necessitados (SPAAN). Results The age group of the patients with fractures in the proximal extremity of the femur ranged from 65 to 96 years (mean: 77.58). The main type of fracture was trochanteric (47; 62.2%), followed by femoral neck fractures (27; 36%). Among the patients who presented on fracturing the proximal extremity of the femur, 12% had low weight, 62.7% normal weight, 24% overweight, and 1.3% obesity. Among the patients without any history of fractures, 5.6% presented low weight, 43.8% normal weight, 33.7% overweight, and 9.8% obesity. It was observed that the patients with fractures in the proximal extremity of the femur (n = 75) presented a mean BMI of 22.6, while the patients without fractures presented a mean BMI of 25.5. Conclusion The patients in the group with fractures were significantly taller than those in the group without fractures and presented significantly lower BMI than those in the group without fractures. PMID:26229845

  20. Posterior tibial slope in medial opening-wedge high tibial osteotomy: 2-D versus 3-D navigation.

    PubMed

    Yim, Ji Hyeon; Seon, Jong Keun; Song, Eun Kyoo

    2012-10-01

    Although opening-wedge high tibial osteotomy (HTO) is used to correct deformities, it can simultaneously alter tibial slope in the sagittal plane because of the triangular configuration of the proximal tibia, and this undesired change in tibial slope can influence knee kinematics, stability, and joint contact pressure. Therefore, medial opening-wedge HTO is a technically demanding procedure despite the use of 2-dimensional (2-D) navigation. The authors evaluated the posterior tibial slope pre- and postoperatively in patients who underwent navigation-assisted opening-wedge HTO and compared posterior slope changes for 2-D and 3-dimensional (3-D) navigation versions. Patients were randomly divided into 2 groups based on the navigation system used: group A (2-D guidance for coronal alignment; 17 patients) and group B (3-D guidance for coronal and sagittal alignments; 17 patients). Postoperatively, the mechanical axis was corrected to a mean valgus of 2.81° (range, 1°-5.4°) in group A and 3.15° (range, 1.5°-5.6°) in group B. A significant intergroup difference existed for the amount of posterior tibial slope change (Δ slope) pre- and postoperatively (P=.04).Opening-wedge HTO using navigation offers accurate alignment of the lower limb. In particular, the use of 3-D navigation results in significantly less change in the posterior tibial slope postoperatively than does the use of 2-D navigation. Accordingly, the authors recommend the use of 3-D navigation systems because they provide real-time intraoperative information about coronal, sagittal, and transverse axes and guide the maintenance of the native posterior tibial slope. Copyright 2012, SLACK Incorporated.

  1. The effects of tibia profile, distraction angle, and knee load on wedge instability and hinge fracture: A finite element study.

    PubMed

    Weng, Pei-Wei; Chen, Chia-Hsien; Luo, Chu-An; Sun, Jui-Sheng; Tsuang, Yang-Hwei; Cheng, Cheng-Kung; Lin, Shang-Chih

    2017-04-01

    Several plate systems for high tibial osteotomy (HTO) have been developed to stabilize the opening wedge of an osteotomized tibia. Among them, the TomoFix system, having a quasi-straight and T-shaped design, has been widely adopted in the literature. However, this system is implemented by inserting a lag (i.e., cortical) screw through the proximal combi-hole, to deform the plate and pull the distal tibia toward the plate. This process potentially induces plate springback and creates an elastic preload on the osteotomized tibia, especially at the lateral hinge of the distracted wedge. Using the finite-element method, this study aims to investigate the contoured effect of lag-screw application on the biomechanical behavior of the tibia-plate construct. Two tibial profiles (normal and more concave), three distraction angles (6°, 9°, and 12°), and three knee loads (intraoperative: contouring plate; postoperative: weight and nonweight bearing) are systematically varied in this study. The wedge instability and fracture risk at the lateral hinge are chosen as the comparison indices. The results show the necessity of preoperative planning for a precontoured procedure, rather than elastic deformation using a lag screw. Within the intraoperative period, a more concave tibial profile and/or reduced distraction angle (i.e., 6° or 9°) necessitate a higher compressive load to elastically deform the plate, thereby deteriorating the lateral-hinge fracture risk. A precontoured plate is recommended in the case that the proximal tibia is highly concave and the distraction angle is insufficient to stretch the tibial profile. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Surgical treatment of avulsion fractures at the tibial insertion of the posterior cruciate ligament: functional result☆

    PubMed Central

    Barros, Marcos Alexandre; Cervone, Gabriel Lopes de Faria; Costa, André Luis Serigatti

    2015-01-01

    Objective To objectively and subjectively evaluate the functional result from before to after surgery among patients with a diagnosis of an isolated avulsion fracture of the posterior cruciate ligament who were treated surgically. Method Five patients were evaluated by means of reviewing the medical files, applying the Lysholm questionnaire, physical examination and radiological examination. For the statistical analysis, a significance level of 0.10 and 95% confidence interval were used. Results According to the Lysholm criteria, all the patients were classified as poor (<64 points) before the operation and evolved to a mean of 96 points six months after the operation. We observed that 100% of the posterior drawer cases became negative, taking values less than 5 mm to be negative. Conclusion Surgical methods with stable fixation for treating avulsion fractures at the tibial insertion of the posterior cruciate ligament produce acceptable functional results from the surgical and radiological points of view, with a significance level of 0.042. PMID:27218073

  3. Elastic nailing of tibia shaft fractures in young children up to 10 years of age.

    PubMed

    Heo, Jeong; Oh, Chang-Wug; Park, Kyeong-Hyeon; Kim, Joon-Woo; Kim, Hee-June; Lee, Jong-Chul; Park, Il-Hyung

    2016-04-01

    Although tibia shaft fractures in children usually have satisfactory results after closed reduction and casting, there are several surgical indications, including associated fractures and soft tissue injuries such as open fractures. Titanium elastic nails (TENs) are often used for pediatric tibia fractures, and have the advantage of preserving the open physis. However, complications such as delayed union or nonunion are not uncommon in older children or open fractures. In the present study, we evaluated children up to 10 years of age with closed or open tibial shaft fractures treated with elastic nailing technique. A total of 16 tibia shaft fractures treated by elastic nailing from 2001 to 2013 were reviewed. The mean patient age at operation was 7 years (range: 5-10 years). Thirteen of 16 cases were open fractures (grade I: 4, grade II: 6, grade IIIA: 3 cases); the other cases had associated fractures that necessitated operative treatments. Closed, antegrade intramedullary nailing was used to insert two nails through the proximal tibial metaphysis. All patients were followed up for at least one year after the injury. Outcomes were evaluated using modified Flynn's criteria, including union, alignment, leg length discrepancies, and complications. All fractures achieved union a mean of 16.1 weeks after surgery (range: 11-26 weeks). No patient reported knee pain or experienced any loss of knee or ankle motion. There was a case of superficial infection in a patient with grade III open fracture. Three patients reported soft tissue discomfort due to prominent TEN tips at the proximal insertion site, which required cutting the tip before union or removing the nail after union. At the last follow-up, there were no angular or rotational deformities over 10° in either the sagittal or coronal planes. With the exception of one case with an overgrowth of 15 mm, no patient showed shortening or overgrowth exceeding 10mm. Among final outcomes, 15 were excellent and 1 was

  4. Effect of rhBMP-2 on tibial plateau fractures in a canine model.

    PubMed

    Schaefer, Susan L; Lu, Yan; Seeherman, Howard; Li, X Jian; Lopez, Mandi J; Markel, Mark D

    2009-04-01

    This study was to determine the efficacy of recombinant human bone morphogenetic protien-2 (rhBMP-2)/calcium phosphate matrix (CPX) paste to accelerate healing in a canine articular fracture model with associated subchondral defect. rhBMP-2/CPX (BMP), CPX alone (CPX) or autogenous bone graft (ABG) was administered to a canine articular tibial plateau osteotomy with a subchondral defect in each of 21 female dogs. The unoperated contralateral limbs served as controls. Ground reaction forces, synovial fluid, radiographic changes, mechanical testing, bone density, and histology of bone and synovium were analyzed at 6 weeks after surgery. Radiographic analysis demonstrated that the BMP and CPX groups showed improved bony healing compared to the ABG group at week 6. Histomorphometric analysis demonstrated that the BMP group had significantly increased trabecular bone volume compared to the CPX and ABG groups. Mechanical testing revealed that the BMP group had significantly greater maximum failure loads than the ABG group. Histological analysis demonstrated that the BMP group had significantly less sub-synovial inflammation than CPX group. This study demonstrated that rhBMP-2/CPX accelerated healing of articular fractures with subchondral defect compared to ABG in most of the parameters evaluated, and had less subsynovial inflammation than the CPX alone in a canine model.

  5. Ankle fractures have features of an osteoporotic fracture.

    PubMed

    Lee, K M; Chung, C Y; Kwon, S S; Won, S H; Lee, S Y; Chung, M K; Park, M S

    2013-11-01

    We report the bone attenuation of ankle joint measured on computed tomography (CT) and the cause of injury in patients with ankle fractures. The results showed age- and gender-dependent low bone attenuation and low-energy trauma in elderly females, which suggest the osteoporotic features of ankle fractures. This study was performed to investigate the osteoporotic features of ankle fracture in terms of bone attenuation and cause of injury. One hundred ninety-four patients (mean age 51.0 years, standard deviation 15.8 years; 98 males and 96 females) with ankle fracture were included. All patients underwent CT examination, and causes of injury (high/low-energy trauma) were recorded. Mean bone attenuations of the talus, medial malleolus, lateral malleolus, and distal tibial metaphysis were measured on CT images. Patients were divided into younger age (<50 years) and older age (≥50 years) groups, and mean bone attenuation and causes of injury were compared between the two groups in each gender. Proportion of low-energy trauma was higher in the older age group than in the younger age group, but the difference was only significant in female gender (p = 0.011). The older age group showed significantly lower bone attenuation in the talus, medial malleolus, lateral malleolus, and distal tibial metaphysis than the younger age group in both genders. The older age group showed more complex pattern of fractures than the younger age group. With increasing age, bone attenuations tended to decrease and the difference of bone attenuation between the genders tended to increase in the talus, medial malleolus, lateral malleolus, and distal tibial metaphysis. Ankle fracture had features of osteoporotic fracture that is characterized by age- and gender-dependent low bone attenuation. Ankle fracture should not be excluded from the clinical and research interest as well as from the benefit of osteoporosis management.

  6. Brachial Plexus Injury in a 6-Year-Old Boy with 100% Displaced Proximal Humeral Metaphyseal Fracture: A Case Presentation.

    PubMed

    Jovanovich, Elizabeth Nora; Howard, James F

    2017-12-01

    Posttraumatic brachial plexopathies can occur following displaced proximal humeral fractures, causing profound functional deficits. Described here is an unusual case of a displaced proximal humeral metaphyseal fracture in a young child. The patient underwent closed reduction and serial casting, but hand weakness and forearm sensory loss persisted. Needle electromyography localized the injury to the mid/proximal arm near the fracture site, resulting in damage to the posterior and medial cords of the brachial plexus with profound involvement of the radial, ulnar, and median nerves and sparing of the axillary nerve. After months of occupational therapy, hand strength improved, with a nearly full return of function. V. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  7. Open-wedge high tibial osteotomy: incidence of lateral cortex fractures and influence of fixation device on osteotomy healing.

    PubMed

    Dexel, Julian; Fritzsche, Hagen; Beyer, Franziska; Harman, Melinda K; Lützner, Jörg

    2017-03-01

    Open-wedge high tibial osteotomy (HTO) is an established treatment for young and middle-aged patients with medial compartment knee osteoarthritis and varus malalignment. Although not intended, a lateral cortex fracture might occur during this procedure. Different fixation devices are available to repair such fractures. This study was performed to evaluate osteotomy healing after fixation with two different locking plates. Sixty-nine medial open-wedge HTO without bone grafting were followed until osteotomy healing. In patients with an intact lateral hinge, no problems were noted with either locking plate. A fracture of the lateral cortex occurred in 21 patients (30.4 %). In ten patients, the fracture was not recognized during surgery but was visible on the radiographs at the 6-week follow-up. Lateral cortex fracture resulted in non-union with the need for surgical treatment in three out of eight (37.5 %) patients using the newly introduced locking plate (Position HTO Maxi Plate), while this did not occur with a well-established locking plate (TomoFix) (0 out of 13, p = 0.023). With regard to other adverse events, no differences between both implants were observed. In cases of lateral cortex fracture, fixation with a smaller locking plate resulted in a relevant number of non-unions. Therefore, it is recommended that bone grafting, another fixation system, or an additional lateral fixation should be used in cases with lateral cortex fracture. III.

  8. Plate Fixation With Autogenous Calcaneal Dowel Grafting Proximal Fourth and Fifth Metatarsal Fractures: Technique and Case Series.

    PubMed

    Seidenstricker, Chad L; Blahous, Edward G; Bouché, Richard T; Saxena, Amol

    Metaphyseal and proximal diaphyseal fractures of the lateral column metatarsals can have problems with healing. In particular, those involving the fifth metatarsal have been associated with a high nonunion rate with nonoperative treatment. Although intramedullary screw fixation results in a high union rate, delayed healing and complications can occur. We describe an innovative technique to treat both acute and chronic injuries involving the metatarsal base from the metaphysis to the proximal diaphyseal bone of the fourth and fifth metatarsals. The surgical technique involves evacuation of sclerotic bone at the fracture site, packing the fracture site with compact cancellous bone, and plate fixation. In our preliminary results, 4 patients displayed 100% radiographic union at a mean of 4.75 (range 4 to 6) weeks with no incidence of refracture, at a mean follow-up point of 3.5 (range 1 to 5) years. The early results with our small series suggest that this technique is a useful treatment choice for metaphyseal and proximal diaphyseal fractures of the fourth and fifth metatarsals. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.

    PubMed

    Röderer, Götz; Scola, Alexander; Schmölz, Werner; Gebhard, Florian; Windolf, Markus; Hofmann-Fliri, Ladina

    2013-10-01

    Proximal humerus fracture fixation can be difficult because of osteoporosis making it difficult to achieve stable implant anchorage in the weak bone stock even when using locking plates. This may cause implant failure requiring revision surgery. Cement augmentation has, in principle, been shown to improve stability. The aim of this study was to investigate whether augmentation of particular screws of a locking plate aimed at a region of low bone quality is effective in improving stability in a proximal humerus fracture model. Twelve paired human humerus specimens were included. Quantitative computed tomography was performed to determine bone mineral density (BMD). Local bone quality in the direction of the six proximal screws of a standard locking plate (PHILOS, Synthes) was assessed using mechanical means (DensiProbe™). A three-part fracture model with a metaphyseal defect was simulated and fixed with the plate. Within each pair of humeri the two screws aimed at the region of the lowest bone quality according to the DensiProbe™ were augmented in a randomised manner. For augmentation, 0.5 ml of bone cement was injected in a screw with multiple outlets at its tip under fluoroscopic control. A cyclic varus-bending test with increasing upper load magnitude was performed until failure of the screw-bone fixation. The augmented group withstood significantly more load cycles. The correlation of BMD with load cycles until failure and BMD with paired difference in load cycles to failure showed that augmentation could compensate for a low BMD. The results demonstrate that augmentation of screws in locked plating in a proximal humerus fracture model is effective in improving primary stability in a cyclic varus-bending test. The augmentation of two particular screws aimed at a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality

  10. All-Polyethylene Tibial Components: An Analysis of Long-Term Outcomes and Infection.

    PubMed

    Houdek, Matthew T; Wagner, Eric R; Wyles, Cody C; Watts, Chad D; Cass, Joseph R; Trousdale, Robert T

    2016-07-01

    There is debate regarding tibial component modularity and composition in total knee arthroplasty (TKA). Biomechanical studies have suggested improved stress distribution in metal-backed tibias; however, these results have not translated clinically. The purpose of this study was to analyze the outcomes of all-polyethylene components and to compare the results to those with metal-backed components. We reviewed 31,939 patients undergoing a primary TKA over a 43-year period (1970-2013). There were 28,224 (88%) metal-backed and 3715 (12%) all-polyethylene tibial components. The metal-backed and all-polyethylene groups had comparable demographics with respect to gender, age and body mass index (BMI). Mean follow-up was 7 years. The mean survival for all primary TKAs at the 5-, 10-, 20- and 30-year time points was 95%, 89%, 73%, and 57%, respectively. All-polyethylene tibial components were found to have a significantly improved (P < .0001) survivorship when compared with their metal-backed counterparts. All-polyethylene tibial components were also found to have a significantly lower rate of infection, instability, tibial component loosening, and periprosthetic fracture. The all-polyethylene group had improved survival rates in all age groups, except in patients 85 years old or greater, where there was no significant difference. All-polyethylene tibial components had improved survival for all BMI groups except in the morbidly obese (BMI ≥ 40) where there was no significant difference. All-polyethylene tibial components had significantly improved implant survival, reduced rates of postoperative infection, fracture, and tibial component loosening. All polyethylene should be considered for most of the patients, regardless of age and BMI. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones using bioabsorbable screws.

    PubMed

    Mageed, M; Steinberg, T; Drumm, N; Stubbs, N; Wegert, J; Koene, M

    2018-03-01

    Fractures involving the proximal one-third of the splint bone are relatively rare and are challenging to treat. A variety of management techniques have been reported in the literature. The aim of this retrospective case series was to describe the clinical presentation and evaluate the efficacy of bioabsorbable polylactic acid screws in internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones in horses. The medical records, diagnostic images and outcome of all horses diagnosed with a proximal fracture of the splint bones and treated with partial resection and internal fixation of the proximal stump using bioabsorbable polylactic acid screws between 2014 and 2015 were reviewed. Eight horses met the inclusion criteria. The results showed that there were no complications encountered during screw placement or postoperatively. Six horses returned to full work 3 months after the operation and two horses remained mildly lame. On follow-up radiographs 12 months postoperatively (n = 2) the screws were not completely absorbed. The screws resulted in a cone-shaped radiolucency, which was progressively replaced from the outer margins by bone sclerosis. The use of bioabsorbable screws for fixation of proximal fractures of the splint bone appears to be a safe and feasible technique and may offer several advantages over the use of traditional metallic implants. © 2018 Australian Veterinary Association.

  12. Short frontal plane fractures involving the dorsoproximal articular surface of the proximal phalanx: Description of the injury and a technique for repair.

    PubMed

    Wright, I M; Minshall, G J

    2018-01-01

    Chip fractures of the dorsoproximal articular margin of the proximal phalanx are common injuries in racehorses. Large fractures can extend distal to the joint capsule insertion and have been described as dorsal frontal fractures. To report the location and morphology of short frontal plane fractures involving the dorsoproximal articular surface of the proximal phalanx and describe a technique for repair under arthroscopic and radiographic guidance. Single centre retrospective case study. Case records of horses with frontal plane fractures restricted to the dorsoproximal epiphysis and metaphysis of the proximal phalanx referred to Newmarket Equine Hospital were retrieved, images reviewed and lesion morphology described. A technique for repair and the results obtained are reported. A total of 22 fractures in 21 horses commencing at the proximal articular surface exited the dorsal cortex of the proximal phalanx distal to the metacarpophalangeal/metatarsophalangeal joint capsule in 17 hind- and five forelimbs. All were in Thoroughbred racehorses. In 16 cases these were acute racing or training injuries; 20 fractures were medial, one lateral and one was midline. All were repaired with a single lag screw using arthroscopic and radiographically determined landmarks. A total of 16 horses raced after surgery with performance data similar to their preinjury levels. The study demonstrates substantial morphological similarities between individual lesions supporting a common pathophysiology, but does not identify precise causation. There are no cases managed differently that might permit assessment of the comparative efficacy of the treatment described. Short frontal plane fractures involving the dorsoproximal margin of the proximal phalanx that exit the bone distal to the metacarpophalangeal/metatarsophalangeal joint capsule have substantial morphological similarities, are amenable to minimally invasive repair and carry a good prognosis for return to training and racing.

  13. Intramedullary nailing versus plating for extra-articular distal tibial metaphyseal fracture: a systematic review and meta-analysis.

    PubMed

    Xue, Xing-He; Yan, Shi-Gui; Cai, Xun-Zi; Shi, Ming-Min; Lin, Tiao

    2014-04-01

    With development in the techniques of reduction and fixation, there has been a controversy in comparison between intramedullary nailing (IMN) and plating for the treatment of distal tibial metaphyseal fracture (DTF). The study aimed to investigate: (1) which fixation, IMN or plating, was better in the clinical outcomes and in the complications for the treatment of DTF and (2) which modifying variables affected the comparative results between the two modalities. PubMed, EMBASE, OVID, Scopus, ISI Web of Science, the Cochrane Library, Google Scholar and specific orthopaedic journals were searched from inception to July 2013, using the search strategy of '('Fracture Fixation, Intramedullary' [MeSH]) AND ('Tibial Fractures' [MeSH]) AND (plate OR plating)'. All prospective and retrospective controlled trials comparing function, pain, bone union and complications between IMN and plating for DTF were identified. Our analysis had no limitation of the language or the publication year. The primary outcome measurements were complication rate, union time, operation time and hospital stays, while the secondary outcome measurements were functional score and pain score. Fourteen of 6620 studies with 842 patients were included. IMN was probably preferential to plating for DTF given its higher functional score (p=0.01), lower risk of infection (p=0.02) and comparable pain score (p=0.33), total complication rate (p=0.53) and time to union (p=0.86). However, plating had a lower malunion rate than IMN (p<0.0001). All the results were based on the Grading of Recommendations Assessment, Development and Evaluation (GRADE) evidence of moderate quality. With a satisfying alignment obtained, IMN may be preferential to plating for fixation of DTF with better function and lower risk of infection. However, IMN showed higher malunion rate for fixation of DTF. With the biases in our meta-analysis, it will ultimately require a rigorous and adequately powered randomised controlled trial (RCT) to

  14. Post-traumatic cerebral fat embolism prior to operative repair of femoral and tibial fractures.

    PubMed

    Kim, Kyung-Cheon; Hwang, Deuk-Soo; Shin, Hyun-Dae

    2008-02-01

    Rare cases of primary cerebral fat embolism as a postoperative complication have been reported. In addition, cerebral fat embolism occurring before operative repair without shunt lesion are more rarely reported. We report a patient with a posttraumatic cerebral fat embolism resulting in severe neurologic dysfunction without right to left shunt. A 25-year-old man was brought to the hospital immediately after a traffic accident. He sustained a right segmental femoral shaft fracture and a left tibial shaft fracture. The patient was alert with no neurological deficits. Approximately 13 hours after injury, the patient developed acute mental status deterioration and dyspnea. Magnetic resonance imaging of the brain revealed extensive multifocal infarction owing to embolic showering throughout nearly the entire brain parenchyma. Computed tomography with intravenous contrast revealed no evidence of embolism in the lung, abdomen, and pelvis. Transthoracic and transesophageal echocardiogram revealed no circulating embolic particles or intracardiac shunt. The patient underwent closed reduction and internal fixation with a reamed intramedullary nail in the tibia and underwent open reduction and internal fixation with a reamed nail in the femur at 5 days after injury. We performed decompression of a hematoma containing a large number of lipid droplets via a small incision in the femur shaft fracture, established suction drainage of the tibia medullar cavity, and applied a tourniquet to the thigh in the tibia shaft fracture. Supportive medical treatment included endotracheal ventilatory support and tracheostomy. The patient was discharged from the hospital 50 days after admission. On follow-up 2 months later, he had returned to activities of daily living, however a speech disturbance remained.

  15. The Protective Effects of Exclusive Enteral Nutrition Formulas on Growth Factor Expression and the Proximal Tibial Epiphyseal Growth Plate in a TNBS-Induced IBD Rat Model.

    PubMed

    Shi, Jieru; Huang, Zhiheng; Wang, Yuhuan; Huang, Ying

    2015-07-01

    This study aimed to evaluate the effectiveness of different types of nutritional formulas in a rat model of TNBS-induced IBD. IBD was induced with TNBS in 4-week-old rats that were then fed different exclusive enteral nutrition diets for 7 days. The length of the tibia and the number of chondrocytes in the proximal tibias were analyzed at 7 days after supplementation. Immunohistochemical analysis, ELISA and real-time PCR were performed to evaluate the levels of growth hormone receptor (GHR) and insulin-like growth factor-I receptor (IGF-IR), the growth factors IGF-I and insulin-like growth factor-binding protein-3 (IGFBP3) , bone morphogenetic protein (BMP)-2 and BMP-6 respectively. The results demonstrated that the tibia length of the peptide formula group was longer than that of the IBD-Modulen(®) formula and normal diet groups (P < 0.05). Furthermore, the number of chondrocytes of the proximal tibial was more pronounced in the peptide formula group compared to the other groups (P < 0.05). The peptide formula was also more effective in increasing the expression of GHR compared to the other groups (P < 0.05), while the expression of IGF-IR was not significantly different (P > 0.05). In addition, the IGF-I and IGFBP3 levels were more pronounced in the peptide formula supplement group (P < 0.05), and the expression of BMP-2 and BMP-6 mRNA in the proximal tibia growth plate from the peptide formula group was higher than that in the ordinary formula and normal diet groups (P < 0.05). EEN, and particularly a peptide formula, exerted protective effects on the proximal tibial epiphyseal growth plate in a TNBS-induced IBD model.

  16. [Measurement of screw length through drilling technique in osteosynthesis of the proximal humerus fractures].

    PubMed

    Avcı, Cem Coşkun; Gülabi, Deniz; Sağlam, Necdet; Kurtulmuş, Tuhan; Saka, Gürsel

    2013-01-01

    This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesis using locking anatomical proximal humerus plates (PHILOS) in our clinic with the diagnosis of Neer type 2, 3 or 4 were included. Two different surgical techniques were used to measure proximal screw length in the plate and patients were divided into two groups based on the technique used. In group 1, screw length was determined by a 3 mm blunt tipped Kirschner wire without fluoroscopic control. In group 2, bilateral fluoroscopic images for each screw at least were obtained. Intraarticular screw penetration was detected in five patients (10.6%) in group 1, and in 19 patients (37.3%) in group 2. The mean fluoroscopic imaging time was 10.6 seconds in group 1 and 24.8 seconds in group 2, indicating a statistically significant difference. Screw length measurement through the drilling technique significantly reduces the intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures using PHILOS plates.

  17. Outcomes after arthroscopic excision of the bony prominence in the treatment of tibial spine avulsion fractures.

    PubMed

    Shelbourne, K Donald; Urch, Scott E; Freeman, Heather

    2011-06-01

    The purpose of this study was to determine the outcomes after arthroscopic excision of the bony prominence after a tibial spine avulsion fracture. This study included 7 subjects (5 female and 2 male subjects; mean age, 21.4 years). All subjects underwent preoperative rehabilitation focused on range of motion (ROM) and swelling control. Postoperative rehabilitation focused on regaining symmetric knee hyperextension and flexion. Objective examinations and subjective surveys were obtained at least 1 year after surgery. All subjects achieved normal knee extension; 6 patients achieved normal knee flexion, whereas 1 patient had nearly normal flexion. Physical examination showed a negative Lachman test with a firm end point in all patients, and the mean side-to-side difference for the KT-1000 manual maximum test (MEDmetric, San Diego, CA) was 1.3 mm. No subjects required subsequent anterior cruciate ligament reconstruction. All subjects returned to their previous level of activity without instability symptoms. At a mean of 5.7 years after surgery, the mean International Knee Documentation Committee subjective survey score was 90.6 points overall, with 4.7 out of 5 possible points for the instability question. At latest follow-up, the mean ROM was from 6° of hyperextension to 147° of flexion in the involved knee, compared with 6° of hyperextension to 148° of flexion for the noninvolved knee. The results of arthroscopic excision of the bony fragment after type II, III, or III+ tibial spine avulsion fracture are positive, with good stability, symmetric ROM, and high subjective scores. Most importantly, this procedure allows patients to regain full, symmetric hyperextension of the knee, avoiding the complications associated with extension loss. Level IV, therapeutic case series. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator.

    PubMed

    Tafazal, Suhayl; Madan, Sanjeev S; Ali, Farhan; Padman, Manoj; Swift, Simone; Jones, Stanley; Fernandes, James A

    2014-05-01

    The use of circular fixators for the treatment of tibial fractures is well established in the literature. The aim of this study was to compare the Ilizarov circular fixator (ICF) with the Taylor spatial frame (TSF) in terms of treatment results in consecutive patients with tibial fractures that required operative management. A retrospective analysis of patient records and radiographs was performed to obtain patient data, information on injury sustained, the operative technique used, time duration in frame, healing time and complications of treatment. The minimum follow-up was 24 months. Ten patients were treated with ICF between 2000 and 2005, while 15 patients have been treated with TSF since 2005. Two of the 10 treated with ICF and 5 of the 15 treated with TSF were open fractures. All patients went on to achieve complete union. Mean duration in the frame was 12.7 weeks for ICF and 14.8 weeks for the TSF group. Two patients in the TSF group had delayed union and required additional procedures including adjustment of fixator and bone grafting. There was one malunion in the TSF group that required osteotomy and reapplication of frame. There were seven and nine pin-site infections in the ICF and TSF groups, respectively, all of which responded to antibiotics. There were no refractures in either group. In an appropriate patient, both types of circular fixator are equally effective but have different characteristics, with TSF allowing for postoperative deformity correction. Of concern are the two cases of delayed union in the TSF group, all in patients with high-energy injuries. We feel another larger study is required to provide further clarity in this matter. Level II-comparative study.

  19. Variation in tibial functionality and fracture susceptibility among healthy, young adults arises from the acquisition of biologically distinct sets of traits.

    PubMed

    Jepsen, Karl J; Evans, Rachel; Negus, Charles H; Gagnier, Joel J; Centi, Amanda; Erlich, Tomer; Hadid, Amir; Yanovich, Ran; Moran, Daniel S

    2013-06-01

    Physiological systems like bone respond to many genetic and environmental factors by adjusting traits in a highly coordinated, compensatory manner to establish organ-level function. To be mechanically functional, a bone should be sufficiently stiff and strong to support physiological loads. Factors impairing this process are expected to compromise strength and increase fracture risk. We tested the hypotheses that individuals with reduced stiffness relative to body size will show an increased risk of fracturing and that reduced strength arises from the acquisition of biologically distinct sets of traits (ie, different combinations of morphological and tissue-level mechanical properties). We assessed tibial functionality retrospectively for 336 young adult women and men engaged in military training, and calculated robustness (total area/bone length), cortical area (Ct.Ar), and tissue-mineral density (TMD). These three traits explained 69% to 72% of the variation in tibial stiffness (p < 0.0001). Having reduced stiffness relative to body size (body weight × bone length) was associated with odds ratios of 1.5 (95% confidence interval [CI], 0.5-4.3) and 7.0 (95% CI, 2.0-25.1) for women and men, respectively, for developing a stress fracture based on radiography and scintigraphy. K-means cluster analysis was used to segregate men and women into subgroups based on robustness, Ct.Ar, and TMD adjusted for body size. Stiffness varied 37% to 42% among the clusters (p < 0.0001, ANOVA). For men, 78% of stress fracture cases segregated to three clusters (p < 0.03, chi-square). Clusters showing reduced function exhibited either slender tibias with the expected Ct.Ar and TMD relative to body size and robustness (ie, well-adapted bones) or robust tibias with reduced residuals for Ct.Ar or TMD relative to body size and robustness (ie, poorly adapted bones). Thus, we show there are multiple biomechanical and thus biological pathways leading to reduced function and

  20. Utility of double-contrast multi-detector CT scans to assess cartilage thickness after tibial plafond fracture

    PubMed Central

    Thomas, Thaddeus P.; Van Hofwegen, Christopher J.; Anderson, Donald D.; Brown, Thomas D.; Marsh, J. Lawrence

    2010-01-01

    The pathophysiology of post-traumatic osteoarthritis (PTOA) after intra-articular fractures is poorly understood. Pursuit of a better understanding of this disease is complicated by inability to accurately monitor its onset, progression and severity. Common radiographic methods used to assess PTOA do not provide sufficient image quality for precise cartilage measurements. Double-contrast MDCT is an alternative method that may be useful, since it produces high-quality images in normal ankles. The purpose of this study was to assess this technique’s performance in assessing cartilage maintenance in ankles with an intra-articular fracture. Thirty-six tibial plafond fractures were followed over two years, with thirty-one MDCTs being obtained four months after injury, and twenty-two MDCTs after two years. Unfortunately, clinical results with this technique were unreliable due to pathology (presumed arthrofibrosis) and technical problems (pooling of contrast). The arthrofibrosis that developed in many patients inhibited proper joint access and contrast infiltration, although high-quality images were obtained in eleven patients. In this patient subset, in which focal regions of cartilage degeneration could be visualized, thickness could be measured with a high degree of fidelity. While thus useful in selected instances, double-contrast MDCT was too unreliable to be recommended to assess these particular types of injuries. PMID:20634971

  1. Physeal growth arrest after tibial lengthening in achondroplasia

    PubMed Central

    2012-01-01

    Background and purpose Bilateral tibial lengthening has become one of the standard treatments for upper segment-lower segment disproportion and to improve quality of life in achondroplasia. We determined the effect of tibial lengthening on the tibial physis and compared tibial growth that occurred at the physis with that in non-operated patients with acondroplasia. Methods We performed a retrospective analysis of serial radiographs until skeletal maturity in 23 achondroplasia patients who underwent bilateral tibial lengthening before skeletal maturity (lengthening group L) and 12 achondroplasia patients of similar height and age who did not undergo tibial lengthening (control group C). The mean amount of lengthening of tibia in group L was 9.2 cm (lengthening percentage: 60%) and the mean age at the time of lengthening was 8.2 years. The mean duration of follow-up was 9.8 years. Results Skeletal maturity (fusion of physis) occurred at 15.2 years in group L and at 16.0 years in group C. The actual length of tibia (without distraction) at skeletal maturity was 238 mm in group L and 277 mm in group C (p = 0.03). The mean growth rates showed a decrease in group L relative to group C from about 2 years after surgery. Physeal closure was most pronounced on the anterolateral proximal tibial physis, with relative preservation of the distal physis. Interpretation Our findings indicate that physeal growth rate can be disturbed after tibial lengthening in achondroplasia, and a close watch should be kept for such an occurrence—especially when lengthening of more than 50% is attempted. PMID:22489887

  2. Initial varus displacement of proximal humerus fractures results in similar function but higher complication rates.

    PubMed

    Capriccioso, Christina E; Zuckerman, Joseph D; Egol, Kenneth A

    2016-04-01

    To investigate the effect of initial varus or valgus surgical neck alignment on outcomes of patients who sustained proximal humerus fractures treated with open reduction and internal fixation (ORIF). An institutional review board approved database of proximal humerus fractures treated with locked plates was reviewed. Of 185 fractures in the database, 101 fractures were identified and met inclusion criteria. Initial varus displacement was seen in 47 fractures (OTA types 11.A2.2, A3.1, A3.3, B1.2, B2.2, C1.2, C2.2, or C2.3) and initial valgus displacement was observed in 54 fractures (OTA types 11.A2.3, B1.1, C1.1, or C2.1). All patients were treated in a similar manner and examined by the treating physician at standard intervals. Functional outcomes were quantified via the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and physical examination data at 12 months. Radiographs were reviewed for complications of healing. Additionally, complication rate and reoperation rate were investigated. Patients who presented with initial varus displacement had an average age of 59.3 years, while patients in the valgus group had an average age of 62.4 years. Overall, there was no statistically significant difference in age, sex distribution, BMI, fracture parts, screws used, or implant plate type between the two groups. At a minimum 12 months follow up, there was no significant difference in DASH scores between those presenting with varus versus valgus fracture patterns. In addition, no significant differences were seen in final shoulder range of motion in any plane. Overall, 30 patients included in this study developed a complication. A significantly greater number of patients in the initial varus cohort developed complications (40.4%), as compared to 20.3% of patients in the initial valgus cohort (P=0.03). Fourteen patients in this study underwent reoperation. Nine of these patients were in the varus cohort, while 5 were in the valgus cohort (P=0.15). In this

  3. Failed Surgical Management of Acute Proximal Fifth Metatarsal (Jones) Fractures: A Retrospective Case Series and Literature Review.

    PubMed

    Granata, Jaymes D; Berlet, Gregory C; Philbin, Terrence M; Jones, Grant; Kaeding, Christopher C; Peterson, Kyle S

    2015-12-01

    Nonunion, delayed union, and refracture after operative treatment of acute proximal fifth metatarsal fractures in athletes is uncommon. This study was a failure analysis of operatively managed acute proximal fifth metatarsal fractures in healthy athletes. We identified 149 patients who underwent operative treatment for fifth metatarsal fractures. Inclusion criteria isolated skeletally mature, athletic patients under the age of 40 with a minimum of 1-year follow-up. Patients were excluded with tuberosity fractures, fractures distal to the proximal metaphyseal-diaphyseal region of the fifth metatarsal, multiple fractures or operative procedures, fractures initially treated conservatively, and medical comorbidities/risk factors for nonunion. Fifty-five patients met the inclusion/exclusion criteria. Four (7.3%) patients required a secondary operative procedure due to refracture. The average time to refracture was 8 months. All refractures were associated with bent screws and occurred in male patients who participated in professional basketball, professional volleyball, and college football. The average time for release to progressive weight-bearing was 6 weeks. Three patients were revised to a bigger size screw and went on to union. One patient was revised to the same-sized screw and required a second revision surgery for nonunion. All failures were refractures in competitive athletes who were initially treated with small diameter solid or cannulated stainless steel screws. The failures were not associated with early postoperative weight-bearing protocol. Maximizing initial fixation stiffness may decrease the late failure rate in competitive athletes. More clinical studies are needed to better understand risk factors for failure after screw fixation in the competitive, athletic population. Prognostic, Level IV: Case series. © 2015 The Author(s).

  4. Midterm results of surgical treatment of displaced proximal humeral fractures in children.

    PubMed

    Pavone, Vito; de Cristo, Claudia; Cannavò, Luca; Testa, Gianluca; Buscema, Antonio; Condorelli, Giuseppe; Sessa, Giuseppe

    2016-07-01

    To analyse the clinical outcomes of 26 children treated surgically for displaced proximal humerus fracture. From January 2008 to December 2012, 26 children/adolescents (14 boys, 12 girls) were treated surgically for displaced fractures at the proximal extremity of the humerus. Ten were grade III and 16 were grade IV according to the Neer-Horowitz classification with a mean age of 12.8 ± 4.2 years. Twenty young patients were surgically treated with a closed reduction and direct percutaneous pinning; six required an open approach. To obtain a proper analysis, we compared the Costant scores with the contralateral shoulder (Δ Costant). The mean follow-up period was 34 months (range 10-55). Two grade IV patients showed a loss in the reduction after percutaneous treatment. This required open surgery with a plate and screws. On average, the treated fractures healed at 40 days. The mean Δ Costant score was 8.43 (range 2-22). There was a statistically significant improvement in the mean Δ Costant score in grade III patients. In grade IV patients, there was a significant improvement in the mean Δ Costant score in those treated with open surgery versus mini-invasive surgery. Our study shows excellent results with percutaneous k-wires. This closed surgery had success in these patients, and the excellent outcomes noted here lead us to prefer the mini-invasive surgical approach in NH grade III fractures. In grade IV, the best results were noted in patients treated with open surgery. We suggest an open approach for these patients. III.

  5. In vivo biomechanical evaluation of a novel angle-stable interlocking nail design in a canine tibial fracture model.

    PubMed

    Déjardin, Loïc M; Cabassu, Julien B; Guillou, Reunan P; Villwock, Mark; Guiot, Laurent P; Haut, Roger C

    2014-03-01

    To compare clinical outcome and callus biomechanical properties of a novel angle stable interlocking nail (AS-ILN) and a 6 mm bolted standard ILN (ILN6b) in a canine tibial fracture model. Experimental in vivo study. Purpose-bred hounds (n = 11). A 5 mm mid-diaphyseal tibial ostectomy was stabilized with an AS-ILN (n = 6) or an ILN6b (n = 5). Orthopedic examinations and radiographs were performed every other week until clinical union (18 weeks). Paired tibiae were tested in torsion until failure. Callus torsional strength and toughness were statistically compared and failure mode described. Total and cortical callus volumes were computed and statistically compared from CT slices of the original ostectomy gap. Statistical significance was set at P < .05 RESULTS: From 4 to 8 weeks, lameness was less pronounced in AS-ILN than ILN6b dogs (P < .05). Clinical union was reached in all AS-ILN dogs by 10 weeks and in 3/5 ILN6b dogs at 18 weeks. Callus mechanical properties were significantly greater in AS-ILN than ILN6b specimens by 77% (failure torque) and 166% (toughness). Failure occurred by acute spiral (control and AS-ILN) or progressive transverse fractures (ILN6b). Cortical callus volume was 111% greater in AS-ILN than ILN6b specimens (P < .05). Earlier functional recovery, callus strength and remodeling suggest that the AS-ILN provides a postoperative biomechanical environment more conducive to bone healing than a comparable standard ILN. © Copyright 2014 by The American College of Veterinary Surgeons.

  6. Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration.

    PubMed

    Carrera, Ion; Gelber, Pablo Eduardo; Chary, Gaetan; González-Ballester, Miguel A; Monllau, Juan Carlos; Noailly, Jerome

    2016-10-01

    To assess, with finite element (FE) calculations, whether immediate weight bearing would be possible after surgical stabilization either with cannulated screws or with a locking plate in a split fracture of the lateral tibial plateau (LTP). A split fracture of the LTP was recreated in a FE model of a human tibia. A three-dimensional FE model geometry of a human femur-tibia system was obtained from the VAKHUM project database, and was built from CT images from a subject with normal bone morphologies and normal alignment. The mesh of the tibia was reconverted into a geometry of NURBS surfaces. A split fracture of the lateral tibial plateau was reproduced by using geometrical data from patient radiographs. A locking screw plate (LP) and a cannulated screw (CS) systems were modelled to virtually reduce the fracture and 80 kg static body-weight was simulated. While the simulated body-weight led to clinically acceptable interfragmentary motion, possible traumatic bone shear stresses were predicted nearby the cannulated screws. With a maximum estimation of about 1.7 MPa maximum bone shear stresses, the Polyax system might ensure more reasonable safety margins. Split fractures of the LTP fixed either with locking screw plate or cannulated screws showed no clinically relevant IFM in a FE model. The locking screw plate showed higher mechanical stability than cannulated screw fixation. The locking screw plate might also allow full or at least partial weight bearing under static posture at time zero.

  7. Human parathyroid hormone-(1-38) restores cancellous bone to the immobilized, osteopenic proximal tibial metaphysis in rats

    NASA Technical Reports Server (NTRS)

    Ma, Y. F.; Jee, W. S. S.; Ke, H. Z.; Lin, B. Y.; Liang, X. G.; Li, M.; Yamamoto, N.

    1994-01-01

    The purpose of this study was to determine if human parathyroid hormone-(1-38) (PTH) can restore cancellous bone mass to the established osteopenic, immobilized proximal tibial metaphyses (PTM) of female rats. The right hindlimbs of six-month-old female Sprague-Dawley rats were immobilized by bandaging the right hindlimbs to the abdomen. After 30 days of right hindlimb immobilization (RHLI), the rats were subcutaneously injected with 200 microgram hPTH(1-38)/kg/day for 15 (short-term) or 75 (longer-term) days. Static bone histomorphometry was performed on the primary spongiosa, while both static and dynamic histomorphometry were performed on the secondary spongiosa of the right PTM. Immobilization for 30 days without treatment decreased trabecular bone area, number and thickness in both primary and secondary spongiosa, and induced an increase in eroded perimeter and a decrease in tissue referent-bone formation rate (BFR/TV) in the secondary spongios. These changes reached a new steady state thereafter. Treatment with 200 microgram hPTH(1-38)/kg/day for 15 days, beginning at 30 days post immobilization (IM), significantly increased trabecular bone area, thickness and number in both primary and secondary spongiosa despite continuous IM when compared to the age-related and IM controls. The short-term (15 days) PTH treatment significantly increased labeling perimeter, mineral apposition rate and BFR/TV in the secondary spongiosa and stimulated longitudinal bone growth as compared to the age-related and IM controls. PTH treatment for longer-term (75 days) further increased trabecular bone area, thickness and number as compared to aging and IM controls and short-term (15 days) PTH treated groups. The bone formation indices in the secondary spongiosa of these longer-term treated rats were lower than that of short-term (15 days) PTH treated group, but they were still higher than those of IM and age-related controls. Our findings indicate that PTH treatment stimulates

  8. The service impact of failed locking plate fixation of distal tibial fractures: a service and financial evaluation at a major trauma centre.

    PubMed

    Kent, Michael; Mumith, Aadil; McEwan, Jo; Hancock, Nicholas

    2015-12-01

    The surgical treatment of distal tibial fractures is challenging and controversial. Recently, locking plate fixation has become popular, but the outcomes of this treatment are mixed with complication rates as high as 50 % in the published literature. There are no reports specifically relating to the financial and resource costs of failed treatment in the literature. Retrospective service analysis of patients who had undergone locking plate fixation of a distal third tibial fracture between 2008 and 2011 with at least 12 months follow-up. Rates of readmission, reoperation, bony union and infection were ascertained. The financial and resource (hospital stay and number of outpatient appointments) implications of failed treatment were calculated. Forty-two patients were identified. There were 31 type A fractures, one type B fracture and 10 type C fractures. Three injuries were open. Twenty patients were treated with minimally invasive percutaneous osteosynthesis (MIPO). The readmission and reoperation rates were 26 % (n = 11) and 19 % (n = 8), respectively. A total of 89 % of readmissions were due to infection. All patients had received appropriate antibiotic regimens. The average costs of successful and failed treatment were £ 5538 and £ 18,335, respectively. The average time to union was 24.5 weeks. The rate of non-union was 21 % (n = 9). The rate of infection was 28 % (n = 12), with all patients with open fracture incurring an infection. Tourniquet time had no effect on the incidence of complications. Smokers were more likely to incur a complication (p < 0.05), and non-union was lower in the MIPO group (p < 0.05). The length and total cost of inpatient care were significantly lower in the MIPO group (p < 0.05). MIPO patients were five times less likely to incur readmission or reoperation. Failed treatment was three times more expensive and four times longer than successful treatment. The study identified a large burden to the service following failure of locking

  9. [Comparison of clinical effect on locking plate for proximal humeral fracture with or without application of inferomedial screws].

    PubMed

    Guo, Xiu-wu; Fan, Jian; Yuan, Feng

    2016-06-01

    To compare clinical outcomes of locking plate for proximal humeral fracture whether application of inferomedial screws. From January 2012 to July 2013, 46 patients with proximal humeral fracture underwent locking plates were retrospectively analyzed. There were 25 males and 21 females aged from 29 to 80 years old with an average of 55.1 years old. Among them, 25 patients were treated with inferomedial screws (support group), including 13 males and 12 females aged from 38 to 80 years old with an average of (55.8 ± 11.8) years old; 8 cases were part two fracture,10 cases were part three fracture and 7 cases were part four fracture according to Neer classification. Twenty-one patients were treated without inferomedial screws (non-support group), including 12 males and 9 females aged from 29 to 79 years old with an average of (54.2 ± 14.8)years old; 6 cases were part two fracture, 9 cases were part three fracture and 6 cases were part four fracture according to Neer classification. Operative time, fracture healing time and complications were observed and compared, Neer scoring of shoulder joint were used to evaluate clinical effect. All patients were followed up from 12 to 41 months with an average of 15.6 months. Operative time and fracture healing time in support group was (1.6 ± 0.4) h and (3.0 ± 0.6) months, and (1.5 ± 0.4) h and (3.1 ± 0.6) months in non-support group, while there was no statistical difference in operative time and fracture healing time between two groups. There was significant differences in Neer score between support group (89.7± 4.9) and non-support group (83.1 ± 7.1). No complication occurred in support group,while 4 cases occurred complications in non-support group. Locking plate with inferomedial screws for proximal humeral fracture has advantages of stable fixation, less complications, quick recovery of function and satisfied clinical effect.

  10. The use of a robotic tibial rotation device and an electromagnetic tracking system to accurately reproduce the clinical dial test.

    PubMed

    Stinton, S K; Siebold, R; Freedberg, H; Jacobs, C; Branch, T P

    2016-03-01

    The purpose of this study was to: (1) determine whether a robotic tibial rotation device and an electromagnetic tracking system could accurately reproduce the clinical dial test at 30° of knee flexion; (2) compare rotation data captured at the footplates of the robotic device to tibial rotation data measured using an electromagnetic sensor on the proximal tibia. Thirty-two unilateral ACL-reconstructed patients were examined using a robotic tibial rotation device that mimicked the dial test. The data reported in this study is only from the healthy legs of these patients. Torque was applied through footplates and was measured using servomotors. Lower leg motion was measured at the foot using the motors. Tibial motion was also measured through an electromagnetic tracking system and a sensor on the proximal tibia. Load-deformation curves representing rotational motion of the foot and tibia were compared using Pearson's correlation coefficients. Off-axis motions including medial-lateral translation and anterior-posterior translation were also measured using the electromagnetic system. The robotic device and electromagnetic system were able to provide axial rotation data and translational data for the tibia during the dial test. Motion measured at the foot was not correlated to motion of the tibial tubercle in internal rotation or in external rotation. The position of the tibial tubercle was 26.9° ± 11.6° more internally rotated than the foot at torque 0 Nm. Medial-lateral translation and anterior-posterior translation were combined to show the path of the tubercle in the coronal plane during tibial rotation. The information captured during a manual dial test includes both rotation of the tibia and proximal tibia translation. All of this information can be captured using a robotic tibial axial rotation device with an electromagnetic tracking system. The pathway of the tibial tubercle during tibial axial rotation can provide additional information about knee

  11. Forecasting Proximal Femur and Wrist Fracture Caused by a Fall to the Side during Space Exploration Missions to the Moon and Mars

    NASA Technical Reports Server (NTRS)

    Lewandowski, Beth E.; Myers, Jerry G.; Sulkowski, C.; Ruehl, K.; Licata, A.

    2008-01-01

    The possibility of bone fracture in space is a concern due to the negative impact it could have on a mission. The Bone Fracture Risk Module (BFxRM) developed at the NASA Glenn Research Center is a statistical simulation that quantifies the probability of bone fracture at specific skeletal locations for particular activities or events during space exploration missions. This paper reports fracture probability predictions for the proximal femur and wrist resulting from a fall to the side during an extravehicular activity (EVA) on specific days of lunar and Martian exploration missions. The risk of fracture at the proximal femur on any given day of the mission is small and fairly constant, although it is slightly greater towards the end of the mission, due to a reduction in proximal femur bone mineral density (BMD). The risk of wrist fracture is greater than the risk of hip fracture and there is an increased risk on Mars since it has a higher gravitational environment than the moon. The BFxRM can be used to help manage the risk of bone fracture in space as an engineering tool that is used during mission operation and resource planning.

  12. Association between findings on palmarodorsal radiographic images and detection of a fracture in the proximal sesamoid bones of forelimbs obtained from cadavers of racing Thoroughbreds.

    PubMed

    Anthenill, Lucy A; Stover, Susan M; Gardner, Ian A; Hill, Ashley E; Lee, Christina M; Anderson, Mark L; Barr, Bradd C; Read, Deryck H; Johnson, Bill J; Woods, Leslie W; Daft, Barbara M; Kinde, Hailu; Moore, Janet D; Farman, Cynthia A; Odani, Jenee S; Pesavento, Patricia A; Uzal, Francisco A; Case, James T; Ardans, Alex A

    2006-05-01

    To determine the distribution for limbs and bones in horses with fractures of the proximal sesamoid bones and relationships with findings on palmarodorsal radiographic images. Proximal sesamoid bones obtained from both forelimbs of cadavers of 328 racing Thoroughbreds. Osteophytes; large vascular channels; and fracture location, orientation, configuration, and margin distinctness were categorized by use of high-detail contact palmarodorsal radiographs. Distributions of findings were determined. Relationships between radiographic findings and fracture characteristics were examined by use of chi2 and logistic regression techniques. Fractures were detected in 136 (41.5%) horses. Biaxial fractures were evident in 109 (80%) horses with a fracture. Osteophytes and large vascular channels were evident in 266 (81%) and 325 (99%) horses, respectively. Medial bones typically had complete transverse or split transverse simple fractures, indistinct fracture margins, > 1 vascular channel that was > 1 mm in width, and osteophytes in abaxial wing and basilar middle or basilar abaxial locations. Lateral bones typically had an oblique fracture and distinct fracture margins. Odds of proximal sesamoid bone fracture were approximately 2 to 5 times higher in bones without radiographic evidence of osteophytes or large vascular channels, respectively. Biaxial fractures of proximal sesamoid bones were common in cadavers of racing Thoroughbreds. Differences between medial and lateral bones for characteristics associated with fracture may relate to differences in fracture pathogeneses for these bones. Osteophytes and vascular channels were common findings; however, fractures were less likely to occur in bones with these features.

  13. Avoidance of malreduction of proximal femoral shaft fractures with the use of a minimally invasive nail insertion technique (MINIT).

    PubMed

    Russell, Thomas A; Mir, Hassan R; Stoneback, Jason; Cohen, Jose; Downs, Brandon

    2008-07-01

    To determine our rate of malalignment in proximal femoral shaft fractures treated with intramedullary (IM) nails, with and without the use of a minimally invasive nail insertion technique (MINIT). Retrospective study. Level 1 trauma center. Between July 1, 2003, and June 31, 2005, 100 consecutive proximal femoral shaft fractures (97 patients) were treated with IM nails. The average age of the 56 men and 41 women was 43.5 years (range, 17 to 96 years). There were 92 closed fractures and 8 open fractures. Fractures were classified according to the Russell-Taylor classification (69 type 1A, 11 type 1B, 3 type 2A, 17 type 2B). All patients underwent antegrade IM nailing using a fracture table in the supine (83) or lateral (17) position. A total of 72 entry portals were trochanteric, and 28 were piriformis. Seventy-seven percent of the femurs were opened with MINIT, a technique that uses a percutaneous cannulated channel reamer over a guide pin as opposed to the standard method of Kuntscher, which employs a femoral awl. Nails were locked proximally using standard locking in 37 fractures, and recon mode in 63. Fracture reduction was examined on immediate postoperative films to determine angulation in the coronal and sagittal planes. Criteria for acceptable reduction were less than 5 degrees angulation in any plane. In addition, surgical position, entry portal, mechanism of injury, Russell-Taylor classification, OTA classification, open or closed fracture, open or closed reduction, and type of implant used were analyzed for significance. The frequency of malalignment was 10% for the entire group of patients. Malalignment occurred in 26% of fractures treated without the use of the MINIT and in 5.2% when the MINIT was used (P < 0.01). There was no statistically significant difference between the different Russell-Taylor fracture types, although there was a trend towards more malalignment in type 2A and 2B fractures (P = 0.06). None of the other factors studied had a

  14. Do modern total knee replacements improve tibial coverage?

    PubMed

    Meier, Malin; Webb, Jonathan; Collins, Jamie E; Beckmann, Johannes; Fitz, Wolfgang

    2018-01-25

    The purpose of the present study is to compare newer designs of various symmetric and asymmetric tibial components and measure tibial bone coverage using the rotational safe zone defined by two commonly utilized anatomic rotational landmarks. Computed tomography scans (CT scans) of one hundred consecutive patients scheduled for total knee arthroplasty were obtained pre-operatively. A virtual proximal tibial cut was performed and two commonly used rotational axes were added for each image: the medio-lateral axis (ML-axis) and the medial 1/3 tibial tubercle axis (med-1/3-axis). Different symmetric and asymmetric implant designs were then superimposed in various rotational positions for best cancellous and cortical coverage. The images were imported to a public domain imaging software, and cancellous and cortical bone coverage was computed for each image, with each implant design in various rotational positions. One single implant type could not be identified that provided the best cortical and cancellous coverage of the tibia, irrespective of using the med-1/3-axis or the ML-axis for rotational alignment. However, it could be confirmed that the best bone coverage was dependent on the selected rotational landmark. Furthermore, improved bone coverage was observed when tibial implant positions were optimized between the two rotational axes. Tibial coverage is similar for symmetric and asymmetric designs, but depends on the rotational landmark for which the implant is designed. The surgeon has the option to improve tibial coverage by optimizing placement between the two anatomic rotational alignment landmarks, the medial 1/3 and the ML-axis. Surgeons should be careful assessing intraoperative rotational tibial placement using the described anatomic rotational landmarks to optimize tibial bony coverage without compromising patella tracking. III.

  15. Complex proximal humeral fractures: a prospective study of 22 cases treated using the "Bilboquet" device.

    PubMed

    Doursounian, L; Kilinc, A; Cherrier, B; Nourissat, G

    2011-02-01

    Despite recent improvements in surgical devices, complex proximal humerus fractures internal fixation still encounters frequent mechanical failures. The aim of this study was to confirm that the Bilboquet device (a design mimicking the cup-and-ball game) helps solving mechanical difficulties associated with these fractures internal fixation and to present a simplified version of the original surgical procedure. This non-randomised prospective study included 22 fractures in 22 patients, mean age: 70 years. According to the Neer classification there were three-part fractures in seven cases and four-part fractures in 15 cases. Fractures were all reduced and treated by internal fixation in a simplified surgical procedure using the Bilboquet device. Mean postoperative follow-up was 34 months. The mean Constant score was 66 and the weighted Constant score was 86. Mean active forward elevation was 108° and mean active external rotation was 28°. No per- or postoperative complications occurred. Initial reduction of the tuberosity was incomplete in four cases. Union was obtained in all fractures. There was no secondary tilting of the head, and no migration or pseudarthrosis of the tuberosities. Five patients developed postoperative avascular necrosis of the humeral head. The Bilboquet staple component provides a supporting platform for the entire humeral head area. This peripheral stabilization associated with tension band wiring explains the lack of secondary displacement in these cases. Although the Bilboquet device provides a solution to the mechanical problems of complex fractures of the proximal humerus, it does not solve the problem of secondary avascular necrosis of the humeral head, which occurred in 23% of the patients in this series and in 33% of patients in the four-part fractures subgroup. IV (non-randomised prospective study). Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  16. [Epidemiology, treatment and results of proximal humeral fractures: experience of a district hospital in a sports- and tourism area].

    PubMed

    Sonderegger, J; Simmen, H-P

    2003-02-01

    The epidemiology, therapy and results of proximal humeral fractures in a touristic area were investigated and our concept for treatment presented. Between 1.1.1999 and 30.04.2000 adult patients with proximal humeral fractures were included, the fractures classified (Codman/Neer and AO) and results determined after an average of 9 months. 62 adults were treated. 59 (95 %) had an accident during leisure time, mainly skiing accidents (52 %). 7 patients (11 %) had an associated luxation of the shoulder. 51 (82 %) were treated conservatively, 11 (18 %) operatively with a T-plate. The conservatively treated had to wear a Gilchrist-cast for an average of 29 (operatively 13) days, started passive movement after 20 (operatively 9) days, and active movement after 44 (operatively 45) days. The 32 employed (52 %) were not able to work for 46 days on average. Overall, 52 patients (84 %) were totally or mostly satisfied with the result. 5 among the 13 patients (38.5 %) with 3- or 4-part-fractures, and 4 among the 11 operated patients (36.4 %) were not satisfied with the result. Proximal humeral fractures are common skiing injuries, they need a long and intensive treatment and are economically expensive. The Codman/Neer and AO-classifications are equal. The results for simple, mainly conservatively treated fractures (Codman/Neer 1, 2A, 2-part) are good. Complex, mainly operatively treated fractures (Codman/Neer 3- and 4-part) have a much poorer prognosis. Diagnostically the computed tomography with 3-D-reconstruction is recommended for a better representation of the fracture and a safer choice of the therapeutical strategy.

  17. Extracorporeal shock wave treatment of non- or delayed union of proximal metatarsal fractures.

    PubMed

    Alvarez, Richard G; Cincere, Brandon; Channappa, Chandra; Langerman, Richard; Schulte, Robert; Jaakkola, Juha; Melancon, Keith; Shereff, Michael; Cross, G Lee

    2011-08-01

    Nonunion or delayed union of fractures in the proximal aspect of metatarsals 1 to 4 and Zone 2 of the fifth metatarsal were treated by high energy extracorporeal shock wave treatment (ESWT) to study the safety and efficacy of this method of treatment in a FDA study of the Ossatron device. In a prospective single-arm, multi-center study, 34 fractures were treated in 32 patients (two subjects had two independent fractures) with ESWT. All fractures were at least 10 (range, 10 to 833) weeks after injury, with a median of 23 weeks. ESWT application was conducted using a protocol totaling 2,000 shocks for a total energy application of approximately 0.22 to 0.51 mJ/mm2 per treatment. The mean ESWT application time for each of the treatments was 24.6 +/- 16.6 minutes, and anesthesia time averaged 27.1 +/- 10.4 minutes. All subjects were followed for 1 year after treatment at intervals of 12 weeks, 6, 9, and 12 months. The overall success rate at the 12-week visit was 71% with low complications, significant pain improvement as well as improvement on the SF-36. The success/fail criteria was evaluated again at the 6- and 12-month followup, showing treatment success rates of 89% (23/26) and 90% (18/20), respectively. The most common adverse event was swelling in the foot, reported by five subjects (15.6%). High-energy ESWT appears to be effective and safe in patients for treatment of nonunion or a delayed healing of a proximal metatarsal, and in fifth metatarsal fractures in Zone 2.

  18. Salvage of tibial pilon fractures using fusion of the ankle with a 90 degrees cannulated blade-plate: a preliminary report.

    PubMed

    Morgan, S J; Thordarson, D B; Shepherd, L E

    1999-06-01

    Six patients with ankle joint destruction and delayed metaphyseal union after tibial plafond fracture were surgically treated with tibiotalar arthrodesis and metaphyseal reconstruction, using a fixed-angle cannulated blade-plate. The procedure was performed through a posterior approach in five cases and a lateral approach in one case. The subtalar joint was preserved in all cases. Metaphyseal union and a stable arthrodesis were obtained in all cases without loss of fixation and with no mechanical failure of the blade-plate. Union was obtained in an average of 26 weeks. No secondary procedures were required to obtain union. All six patients were ambulatory at last follow-up. Stable internal fixation for simultaneous tibiotalar fusion and metaphyseal reconstruction can be achieved with a cannulated blade-plate while preserving the subtalar joint in complex plafond fractures.

  19. [A study of proximal humerus fractures using close reduction and percutaneous minimally invasive fixation].

    PubMed

    Liu, Yin-wen; Kuang, Yong; Gu, Xin-feng; Zheng, Yu-xin; Li, Zhi-qiang; Wei, Xiao-en; Lu, Wei-da; Zhan, Hong-sheng; Shi, Yin-yu

    2011-11-01

    To investigate the clinical effects of close reduction and percutaneous minimally invasive fixation in the treatment of proximal humerus fractures. From April 2008 to March 2010, 28 patients with proximal humerus fracture were treated with close reduction and percutaneous minimally invasive fixation. There were 21 males and 7 females, ranging in age from 22 to 78 years,with an average of 42.6 years. The mean time from suffering injuries to the operation was 1.7 d. Nineteen cases caused by falling down, 9 cases by traffic accident. The main clinical manifestation was swelling, pain and limited mobility of shoulders. According to Neer classification, two part fractures were in 17 cases and three part fractures in 11 cases. The locking proximal humerus plate was used to minimally fixation through deltoid muscle under acromion. The operating time,volume of blood loss, the length of incision and Constant-Murley assessment were applied to evaluate the therapeutic effects. The mean operating time was 40 min, the mean blood loss was 110 ml, and the mean length of incision was about 5.6 cm. The postoperative X-ray showed excellent reduction and the plate and screws were successfully place. Twenty-eight patients were followed up for 6 to 24 months (averaged 14.2 months). The healing time ranged from 6 to 8 weeks and all incision was primarily healed. There were no cases with necrosis head humerus, 24 cases without omalgia, and 4 cases with o-malgia occasionally. All the patients can complete the daily life. The mean score of Constant-Murley assessment was 91.0 +/- 5.8, 24 cases got an excellent result, 3 good and 1 fair. Close reduction and percutaneous minimally invasive fixation, not only can reduce surgical invasive, but also guarantee the early function activities. It has the advantages of less invasive, fixed well and less damage of blood circulation.

  20. A comparative biomechanical analysis of implants for the stabilization of proximal humerus fractures.

    PubMed

    Füchtmeier, B; May, R; Fierlbeck, J; Hammer, J; Nerlich, M

    2006-01-01

    A new humerus nail (Sirus) has become available for the treatment of fractures of the proximal humerus. The aim of the study was the biomechanical comparison of this implant with established systems. 12 matched pairs of human humeri were employed for testing. Three randomized groups were formed (n = 4 pairs). A bending moment of 7.5 Nm and a torsional moment of 8.3 Nm were applied in a test of five loading cycles to all intact bones. Loading was consistently initiated at the distal epiphysis. The consequent deformation at the distal epiphysis was continuously recorded. Then an osteotomy with a defect of 5 mm was created to simulate an unstable subcapital humerus fracture. For paired comparison, one of each pair was stabilized with the Sirus proximal humerus nail. The other side was fixed with a reference implant. The following groups were created.: Group I: Sirus versus Proximal humerus nail (PHN) with spiral blade. Group II: Sirus versus PHILOS plate. Group III: Sirus versus 4.5 mm AO T-plate. The proximal humerus nail (Sirus) demonstrated significantly higher stiffness values than the reference implants for both bending and torsional load. The following values were recorded at a bending moment of 7.5 Nm: Sirus 14.2 mm, PHN 20.7 mm, PHILOS plate 28.1 mm, 4.5 AO T-plate 29.3 mm p < 0.0012). The values at 8.3 Nm torsional moment were: Sirus 8.5 degrees , PHN 12.3 degrees , PHILOS plate 16.4 degrees , 4.5 AO T-Platte 15.6 degrees (p < 0.002). The intramedullary load carriers were biomechanically superior when compared to the plating systems in the fracture model presented here. Supplementary, the Sirus Nail showed higher stiffness values than the PHN. However, the latter are gaining in importance due to the possibility of minimal invasive implantation. Whether this will be associated with functional advantages requires further clinical investigation.

  1. Chronic shin splints. Classification and management of medial tibial stress syndrome.

    PubMed

    Detmer, D E

    1986-01-01

    A clinical classification and treatment programme has been developed for chronic medial tibial stress syndrome. Medial tibial stress syndrome has been reported to be either tibial stress fracture or microfracture, tibial periostitis, or distal deep posterior chronic compartment syndrome. Three chronic types exist and may coexist: Type I (tibial microfracture, bone stress reaction or cortical fracture); type II (periostalgia from chronic avulsion of the periosteum at the periosteal-fascial junction); and type III (chronic compartment syndrome syndrome). Type I disease is treated nonoperatively. Operations for resistant types II and III medial tibial stress syndrome were performed in 41 patients. Bilaterality was common (type II, 50% type III, 88%). Seven had coexistent type II/III; one had type I/II. Preoperative symptoms averaged 24 months in type II, 6 months in type III, and 33 months in types II/III. Mean age was 22 years (15 to 51). Resting compartment pressures were normal in type II (mean 12 mm Hg) and elevated in type III and type II/III (mean 23 mm Hg). Type II and type II/III patients received fasciotomy plus periosteal cauterisation. Type III patients had fasciotomy only. All procedures were performed on an outpatient basis using local anaesthesia. Follow up was complete and averaged 6 months (2 to 14 months). Improved performance was as follows: type II, 93%, type III, 100%; type II/III, 86%. Complete cures were as follows: type II, 78%; type III, 75%; and type II/III, 57%. This experience suggests that with precise diagnosis and treatment involving minimal risk and cost the athlete has a reasonable chance of return to full activity.

  2. Social deprivation influences the epidemiology and outcome of proximal humeral fractures in adults for a defined urban population of Scotland.

    PubMed

    Clement, N D; McQueen, M M; Court-Brown, C M

    2014-10-01

    We present the epidemiology and incidence of proximal humeral fractures over a 17-year period for a defined urban population that represents approximately 13% of the population in Scotland, and functional outcome in relation to the socio-economic status of the patient. The incidence of proximal humeral fractures significantly increased during the study period from 47.9/10(5)/year to 98.7/10(5)/year in 2008 (p < 0.0001), which was greatest for the most socially deprived patients reaching 274.2/10(5)/year in 2008 (p < 0.0001). The most deprived patients sustained their fracture 4 years earlier than the most affluent patients (p = 0.026). Social deprivation was an independent predictor, after adjusting for other confounding variables using multivariable regression analysis, of a significantly worse functional outcome according to the Constant score at 1 year (p = 0.046). Preventative measures, especially for the most socially deprived patients within society, need to be instigated urgently to address the increasing incidence of proximal humeral fractures and alleviate the burden of these morbid fractures in the future. Whether the observed increased incidence is generalisable to a national population would need to be confirmed in future studies.

  3. Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates.

    PubMed

    Somasundaram, K; Huber, C P; Babu, V; Zadeh, H

    2013-04-01

    The aim of our study is to analyse the results of our surgical technique for the treatment of proximal humeral fractures and fracture dislocations using locking plates in conjunction with calcium sulphate bone-substitute augmentation and tuberosity repair using high-strength sutures. We used the extended deltoid-splitting approach for fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Optimal surgical management of proximal humeral fractures remains controversial. Locking plates have become a popular method of fixation. However, failure of fixation may occur if they are used as the sole method of fixation in comminuted fractures, especially in osteopenic bone. We retrospectively analysed 22 proximal humeral fractures in 21 patients; 10 were male and 11 female with an average age of 64.6 years (range 37-77). Average follow-up was 24 months. Eleven of these fractures were exposed by the extended deltoid-splitting approach. Fractures were classified according to Neer and Hertel systems. Preoperative radiographs and computed tomography (CT) scans in three- and four-part fractures were done to assess the displacement and medial calcar length for predicting the humeral head vascularity. According to the Neer classification, there were five two-part, six three-part, five four-part fractures and six fracture-dislocations (two anterior and four posterior). Results were assessed clinically with disabilities of the arm, shoulder and hand (DASH) scores, modified Constant and Murley scores and serial postoperative radiographs. The mean DASH score was 16.18 and the modified Constant and Murley score was 64.04 at the last follow-up. Eighteen out of twenty-two cases achieved good clinical outcome. All the fractures united with no evidence of infection, failure of fixation, malunion, tuberosity failure, avascular necrosis or adverse reaction to calcium sulphate bone substitute. There was no evidence of axillary nerve

  4. [Magnetic resonance imaging of tibial periostitis].

    PubMed

    Meyer, X; Boscagli, G; Tavernier, T; Aczel, F; Weber, F; Legros, R; Charlopain, P; Martin, J P

    1998-01-01

    Tibial periostitis frequently occurs in athletes. We present our experience with MRI in a series of 7 patients (11 legs) with this condition. The clinical presentation and scintigraphic scanning suggested the diagnosis. MRI exploration of 11 legs demonstrated a high band-like juxta-osseous signal enhancement of SE and IR T2 weighted sequences in 6 cases, a signal enhancement after i.v. contrast administration in 4. Tibial periostitis is a clinical diagnosis and MRI and scintigraphic findings can be used to assure the differential diagnosis in difficult cases with stress fracture. MRI can visualize juxta-osseous edematous and inflammatory reactions and an increased signal would appear to be characteristic when the band-like image is fixed to the periosteum.

  5. Operative treatment of 2-part surgical neck fractures of the proximal humerus (AO 11-A3) in the elderly: Cement augmented locking plate Philos™ vs. proximal humerus nail MultiLoc®.

    PubMed

    Helfen, Tobias; Siebenbürger, Georg; Mayer, Marcel; Böcker, Wolfgang; Ockert, Ben; Haasters, Florian

    2016-10-28

    Proximal humeral fractures are with an incidence of 4-5 % the third most common fractures in the elderly. In 20 % of humeral fractures there is an indication for surgical treatment according to the modified Neer-Criteria. A secondary varus dislocation of the head fragment and cutting-out are the most common complications of angle stable locking plates in AO11-A3 fractures of the elderly. One possibility to increase the stability of the screw-bone-interface is the cement augmentation of the screw tips. A second is the use of a multiplanar angle stablentramedullary nail that might provide better biomechanical properties after fixation of 2-part-fractures. A comparison of these two treatment options augmented locking plate versus multiplanar angle stable locking nail in 2-part surgical neck fractures of the proximal humerus has not been carried out up to now. Forty patients (female/male, ≥60 years or female postmenopausal) with a 2-part-fracture of the proximal humerus (AO type 11-A3) will be randomized to either to augmented plate fixation group (PhilosAugment) or to multiplanar intramedullary nail group (MultiLoc). Outcome parameters are Disabilities of the Shoulder, Arm and Hand-Score (DASH) Constant Score (CS), American Shoulder and Elbow Score (ASES), Oxford Shoulder Score (OSS), Range of motion (ROM) and Short Form 36 (SF-36) after 3 weeks, 6 weeks, 3 months, 6 months, 12 and 24 months. Because of the lack of clinical studies that compare cement augmented locking plates with multiplanar humeral nail systems after 2-part surgical neck fractures of the proximal humerus, the decision of surgical method currently depends only on surgeons preference. Because only a randomized clinical trial (RCT) can sufficiently answer the question if one treatment option provides advantages compared to the other method we are planning to perform a RCT. Clinical Trial ( NCT02609906 ), November 18, 2015, registered retrospectively.

  6. What Components Comprise the Measurement of the Tibial Tuberosity-Trochlear Groove Distance in a Patellar Dislocation Population?

    PubMed

    Tensho, Keiji; Akaoka, Yusuke; Shimodaira, Hiroki; Takanashi, Seiji; Ikegami, Shota; Kato, Hiroyuki; Saito, Naoto

    2015-09-02

    The tibial tuberosity-trochlear groove distance is used as an indicator for medial tibial tubercle transfer; however, to our knowledge, no studies have verified whether this distance is strongly affected by tubercle lateralization at the proximal part of the tibia. We hypothesized that the tibial tuberosity-trochlear groove distance is mainly affected by tibial tubercle lateralization at the proximal part of the tibia. Forty-four patients with a history of patellar dislocation and forty-four age and sex-matched controls were analyzed with use of computed tomography. The tibial tuberosity-trochlear groove distance, tibial tubercle lateralization, trochlear groove medialization, and knee rotation were measured and were compared between the patellar dislocation group and the control group. The association between the tibial tuberosity-trochlear groove distance and three other parameters was calculated with use of the Pearson correlation coefficient and partial correlation analysis. There were significant differences in the tibial tuberosity-trochlear groove distance (p < 0.001) and knee rotation (p < 0.001), but there was no difference in the tibial tubercle lateralization (p = 0.13) and trochlear groove medialization (p = 0.08) between the patellar dislocation group and the control group. The tibial tuberosity-trochlear groove distance had no linear correlation with tubercle lateralization (r = 0.21) or groove medialization (r = -0.15); however, knee rotation had a good positive correlation in the patellar dislocation group (r = 0.62). After adjusting for the remaining parameters, knee rotation strongly correlated with the tibial tuberosity-trochlear groove distance (r = 0.69, p < 0.001), whereas tubercle lateralization showed moderate significant correlations in the patellar dislocation group (r = 0.42; p = 0.005). Because the tibial tuberosity-trochlear groove distance is affected more by knee rotation than by tubercle malposition, its use as an indicator for

  7. Ankle fracture spur sign is pathognomonic for a variant ankle fracture.

    PubMed

    Hinds, Richard M; Garner, Matthew R; Lazaro, Lionel E; Warner, Stephen J; Loftus, Michael L; Birnbaum, Jacqueline F; Burket, Jayme C; Lorich, Dean G

    2015-02-01

    The hyperplantarflexion variant ankle fracture is composed of a posterior tibial lip fracture with posterolateral and posteromedial fracture fragments separated by a vertical fracture line. This infrequently reported injury pattern often includes an associated "spur sign" or double cortical density at the inferomedial tibial metaphysis. The objective of this study was to quantitatively establish the association of the ankle fracture spur sign with the hyperplantarflexion variant ankle fracture. Our clinical database of operative ankle fractures was retrospectively reviewed for the incidence of hyperplantarflexion variant and nonvariant ankle fractures as determined by assessment of injury radiographs, preoperative advanced imaging, and intraoperative observation. Injury radiographs were then evaluated for the presence of the spur sign, and association between the spur sign and variant fractures was analyzed. The incidence of the hyperplantarflexion variant fracture among all ankle fractures was 6.7% (43/640). The spur sign was present in 79% (34/43) of variant fractures and absent in all nonvariant fractures, conferring a specificity of 100% in identifying variant fractures. Positive predictive value and negative predictive value were 100% and 99%, respectively. The ankle fracture spur sign was pathognomonic for the hyperplantarflexion variant ankle fracture. It is important to identify variant fractures preoperatively as patient positioning, operative approach, and fixation construct of variant fractures often differ from those employed for osteosynthesis of nonvariant fractures. Identification of the spur sign should prompt acquisition of advanced imaging to formulate an appropriate operative plan to address the variant fracture pattern. Level III, retrospective comparative study. © The Author(s) 2014.

  8. Surgical anatomy of medial open-wedge high tibial osteotomy: crucial steps and pitfalls.

    PubMed

    Madry, Henning; Goebel, Lars; Hoffmann, Alexander; Dück, Klaus; Gerich, Torsten; Seil, Romain; Tschernig, Thomas; Pape, Dietrich

    2017-12-01

    To give an overview of the basic knowledge of the functional surgical anatomy of the proximal lower leg and the popliteal region relevant to medial high tibial osteotomy (HTO) as key anatomical structures in spatial relation to the popliteal region and the proximal tibiofibular joint are usually not directly visible and thus escape a direct inspection. The surgical anatomy of the human proximal lower leg and its relevance for HTO are illustrated with a special emphasis on the individual steps of the operation involving creation of the osteotomy planes and plate fixation. The posteriorly located popliteal neurovascular bundle, but also lateral structures such as the peroneal nerve, the head of the fibula and the lateral collateral ligament must be protected from the instruments used for osteotomy. Neither positioning the knee joint in flexion, nor the posterior thin muscle layer of the popliteal muscle offers adequate protection of the popliteal neurovascular bundle when performing the osteotomy. Tactile feedback through a loss-of-resistance when the opposite cortex is perforated is only possible when sawing and drilling is performed in a pounding fashion. Kirschner wires with a proximal thread, therefore, always need to be introduced under fluoroscopic control. Due to anatomy of the tibial head, the tibial slope may increase inadvertently. Enhanced surgical knowledge of anatomical structures that are at a potential risk during the different steps of osteotomy or plate fixation will help to avoid possible injuries. Expert opinion, Level V.

  9. CORRELATION BETWEEN TIME UNTIL SURGICAL TREATMENT AND MORTALITY AMONG ELDERLY PATIENTS WITH FRACTURES AT THE PROXIMAL END OF THE FEMUR.

    PubMed

    Arliani, Gustavo Gonçalves; da Costa Astur, Diego; Linhares, Glauber Kazuo; Balbachevsky, Daniel; Fernandes, Hélio Jorge Alvachian; Dos Reis, Fernando Baldy

    2011-01-01

    The primary aim of this study was to analyze the possible association between delay in receiving surgical treatment and mortality among elderly patients with fractures at the proximal end of the femur. 269 patients with fractures at the proximal end of the femur (femur neck and intertrochanteric fractures) who were treated surgically at Hospital São Paulo, UNIFESP, São Paulo, between January 2003 and December 2007, were studied. The following attributes were analyzed and compared with the literature relating to this subject: sex, age, type of fracture, classification of the fracture, affected side, synthesis used, trauma mechanism, length of hospitalization, waiting time for surgery, associated comorbidities, hemogram on admission, type of anesthesia, need for blood transfusion, day of the week and season of the year of the fracture. The study showed that higher mortality correlated with higher numbers of clinical comorbidities, longer hospitalization and use of general anesthesia during the surgery. There was no association between the time spent waiting for surgery and mortality.

  10. COMplex Fracture Orthopedic Rehabilitation (COMFORT) - Real-time visual biofeedback on weight bearing versus standard training methods in the treatment of proximal femur fractures in the elderly: study protocol for a multicenter randomized controlled trial.

    PubMed

    Raaben, Marco; Redzwan, Syaiful; Augustine, Robin; Blokhuis, Taco Johan

    2018-04-12

    Proximal femur fractures are a common injury after low energy trauma in the elderly. Most rehabilitation programs are based on restoring mobility and early resumption of weight-bearing. However, therapy compliance is low in patients following lower extremity fractures. Moreover, little is known about the relevance of gait parameters and how to steer the rehabilitation after proximal femur fractures in the elderly. Therefore, the aim of this prospective, randomized controlled trial is to gain insight in gait parameters and evaluate if real-time visual biofeedback can improve therapy compliance after proximal femur fractures in the elderly. This is a two-arm, parallel-design, prospective, randomized controlled trial. Inclusion criteria are age ≥ 60 years, a proximal femur fracture following low energy trauma, and unrestricted-weight bearing. Exclusion criteria are cognitive impairment and limited mobility before trauma. Participants are randomized into either the control group, which receives care as usual, or the intervention group, which receives real-time visual biofeedback about weight-bearing during gait in addition to care as usual. Spatiotemporal gait parameters will be measured in 94 participants per group during a 30-m walk with an ambulatory biofeedback system (SensiStep). The progress of rehabilitation will be evaluated by the primary outcome parameters maximum peak load and step duration in relation to the discharge date. Secondary outcome parameters include other spatiotemporal gait parameters in relation to discharge date. Furthermore, the gait parameters will be related to three validated clinical tests: Elderly Mobility Scale; Functional Ambulation Categories; and Visual Analogue Scale. The primary hypothesis is that participants in the intervention group will show improved and faster rehabilitation compared to the control group. The first aim of this multicenter trial is to investigate the normal gait patterns after proximal femur fractures in

  11. The treatment of complex proximal humeral fractures: analysis of the results of 55 cases treated with PHILOS plate.

    PubMed

    Fattoretto, D; Borgo, A; Iacobellis, C

    2016-08-01

    Complex proximal humerus fractures are often difficult to treat. Their frequency is high, especially in the elderly, and their treatment is still controversial. The aim of this study was to analyze the clinical and radiological results achieved by patients with complex proximal humerus fractures, treated with PHILOS plate only. A cohort of 55 patients was selected. The mean age was 63.4 (range 33-89), while the mean follow-up time was 21.5 months (range 6-75). Clinical outcome was evaluated with the "Constant-Murley shoulder score." All the informations about the presence of complications were gathered, and radiological images were used to calculate the head-shaft angle. The overall mean Constant score was 61.93 ± 18.59, the Individual CS was 70 ± 20 % and the Relative CS was 83 ± 23 %. No significant differences were found between fractures Neer 3 and Neer 4 and between the surgical approaches (delta-split vs. delto-pectoral). Six patients had a fracture with dislocation, seven patients (12.7 %) had complications while in four patients a head-shaft angle beyond the normal range was found. Osteosynthesis with PHILOS plate is stable in the greater part of the cases, and it allows an earlier rehabilitation and so a good functional result, which could be compromised by a prolonged immobilization. Therefore, PHILOS plate is a good option for the treatment of complex proximal humerus fractures.

  12. Intra-epiphyseal stress injury of the proximal tibial epiphysis: preliminary experience of magnetic resonance imaging findings.

    PubMed

    Tony, G; Charran, A; Tins, B; Lalam, R; Tyrrell, P N M; Singh, J; Cool, P; Kiely, N; Cassar-Pullicino, V N

    2014-11-01

    Stress induced injuries affecting the physeal plate or cortical bone in children and adolescents, especially young athletes, have been well described. However, there are no reports in the current English language literature of stress injury affecting the incompletely ossified epiphyseal cartilage. We present four cases of stress related change to the proximal tibial epiphysis (PTE) along with their respective magnetic resonance imaging (MRI) appearances ranging from subtle oedema signal to a pseudo-tumour like appearance within the epiphyseal cartilage. The site and pattern of intra-epiphyseal injury is determined by the type of tissue that is affected, the maturity of the skeleton and the type of forces that are transmitted through the tissue. We demonstrate how an awareness of the morphological spectrum of MRI appearances in intra-epiphyseal stress injury and the ability to identify concomitant signs of stress in other nearby structures can help reduce misdiagnosis, avoid invasive diagnostic procedures like bone biopsy and reassure patients and their families. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Stress fractures: diagnosis, treatment, and prevention.

    PubMed

    Patel, Deepak S; Roth, Matt; Kapil, Neha

    2011-01-01

    Stress fractures are common injuries in athletes and military recruits. These injuries occur more commonly in lower extremities than in upper extremities. Stress fractures should be considered in patients who present with tenderness or edema after a recent increase in activity or repeated activity with limited rest. The differential diagnosis varies based on location, but commonly includes tendinopathy, compartment syndrome, and nerve or artery entrapment syndrome. Medial tibial stress syndrome (shin splints) can be distinguished from tibial stress fractures by diffuse tenderness along the length of the posteromedial tibial shaft and a lack of edema. When stress fracture is suspected, plain radiography should be obtained initially and, if negative, may be repeated after two to three weeks for greater accuracy. If an urgent diagnosis is needed, triple-phase bone scintigraphy or magnetic resonance imaging should be considered. Both modalities have a similar sensitivity, but magnetic resonance imaging has greater specificity. Treatment of stress fractures consists of activity modification, including the use of nonweight-bearing crutches if needed for pain relief. Analgesics are appropriate to relieve pain, and pneumatic bracing can be used to facilitate healing. After the pain is resolved and the examination shows improvement, patients may gradually increase their level of activity. Surgical consultation may be appropriate for patients with stress fractures in high-risk locations, nonunion, or recurrent stress fractures. Prevention of stress fractures has been studied in military personnel, but more research is needed in other populations.

  14. Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid locked/nonlocked screw configurations.

    PubMed

    Estes, Chris; Rhee, Peter; Shrader, M Wade; Csavina, Kristine; Jacofsky, Marc C; Jacofsky, David J

    2008-01-01

    The purpose of this study was to compare the biomechanical properties of a contoured locking plate instrumented with either an all-locked or hybrid locked/nonlocked screw construct in a proximal metaphyseal fracture of the tibia (AO 41-A3.2). A standardized proximal metaphyseal wedge osteotomy (AO 41-A3.2) was created in five pairs of cadaveric tibia. Each pair was randomly instrumented with either an all-locked or combination locked/nonlocked screw construct using a locked contoured periarticular plate (Peri-Loc periarticular locked plating system, Smith & Nephew, Memphis, TN). Vertical subsidence (irreversible deformation) and deflection (reversible deformation) in each pair were analyzed and compared. Load to failure, defined by complete fracture gap closure, was also determined. There was no statistically significant difference in vertical subsidence (P = 0.19) or deflection (P = 0.19) of the proximal tibia between the all-locked and combination locked/nonlocked screw construct with increasing levels of cyclical axial load from 200 to 1200 N. Failure occurred at a mean value of 2160 N in the locked group and 1760 N in the hybrid group (P = 0.19); the failure mode was plate bending in all specimens. The results indicate that the use of compression screws with locked screws in this particular construct allows a similar amount of irreversible and reversible deformation in response to an axial load when compared to an all-locked screw construct. This suggests that there is no statistically significant difference in the stability in fixation between the two methods, allowing the surgeon the freedom to choose the appropriate screw combination unique to each fracture.

  15. Interlocking intramedullary nailing in distal tibial fractures.

    PubMed

    Tyllianakis, M; Megas, P; Giannikas, D; Lambiris, E

    2000-08-01

    This retrospective study examined the results of non-pilon fractures of the distal part of the tibia treated with interlocking intramedullary nailing. Seventy-three patients with equal numbers of fractures treated surgically between 1990 and 1998 were reviewed. Mean patient age was 39.8 years, and follow-up averaged 34.2 months. The AO fracture classification system was used. Concomitant fractures of the lateral malleolus were fixed. All but three fractures achieved union within 4.2 months on average. Satisfactory or excellent results were obtained in 86.3% of patients. These results indicate interlocking intramedullary nailing is a reliable method of treatment for these fractures and is characterized by high rates of union and a low incidence of complications.

  16. Review of fixation techniques for the four-part fractured proximal humerus in hemiarthroplasty.

    PubMed

    Baumgartner, Daniel; Nolan, Betsy M; Mathys, Robert; Lorenzetti, Silvio Rene; Stüssi, Edgar

    2011-07-18

    The clinical outcome of hemiarthroplasty for proximal humeral fractures is not satisfactory. Secondary fragment dislocation may prevent bone integration; the primary stability by a fixation technique is therefore needed to accomplish tuberosity healing. Present technical comparison of surgical fixation techniques reveals the state-of-the-art approach and highlights promising techniques for enhanced stability. A classification of available fixation techniques for three- and four part fractures was done. The placement of sutures and cables was described on the basis of anatomical landmarks such as the rotator cuff tendon insertions, the bicipital groove and the surgical neck. Groups with similar properties were categorized. Materials used for fragment fixation include heavy braided sutures and/or metallic cables, which are passed through drilling holes in the bone fragments. The classification resulted in four distinct groups: A: both tuberosities and shaft are fixed together by one suture, B: single tuberosities are independently connected to the shaft and among each other, C: metallic cables are used in addition to the sutures and D: the fragments are connected by short stitches, close to the fragment borderlines. A plurality of techniques for the reconstruction of a fractured proximal humerus is found. The categorisation into similar strategies provides a broad overview of present techniques and supports a further development of optimized techniques. Prospective studies are necessary to correlate the technique with the clinical outcome.

  17. How much articular displacement can be detected using fluoroscopy for tibial plateau fractures?

    PubMed

    Haller, Justin M; O'Toole, Robert; Graves, Matthew; Barei, David; Gardner, Michael; Kubiak, Erik; Nascone, Jason; Nork, Sean; Presson, Angela P; Higgins, Thomas F

    2015-11-01

    While there is conflicting evidence regarding the importance of anatomic reduction for tibial plateau fractures, there are currently no studies that analyse our ability to grade reduction based on fluoroscopic imaging. The purpose of this study was to determine the accuracy of fluoroscopy in judging tibial plateau articular reduction. Ten embalmed human cadavers were selected. The lateral plateau was sagitally sectioned, and the joint was reduced under direct visualization. Lateral, anterior-posterior (AP), and joint line fluoroscopic views were obtained. The same fluoroscopic views were obtained with 2mm displacement and 5mm displacement. The images were randomised, and eight orthopaedic traumatologists were asked whether the plateau was reduced. Within each pair of conditions (view and displacement from 0mm to 5mm) sensitivity, specificity, and intraclass correlations (ICC) were evaluated. The AP-lateral view with 5mm displacement yielded the highest accuracy for detecting reduction at 90% (95% CI: 83-94%). For the other conditions, accuracy ranged from (37-83%). Sensitivity was highest for the reduced lateral view (79%, 95% CI: 57-91%). Specificity was highest in the AP-lateral view 98% (95% CI: 93-99%) for 5mm step-off. ICC was perfect for the AP-lateral view with 5mm displacement, but otherwise agreement ranged from poor to moderate at ICC=0.09-0.46. Finally, there was no additional benefit to including the joint-line view with the AP and lateral views. Using both AP and lateral views for 5mm displacement had the highest accuracy, specificity, and ICC. Outside of this scenario, agreement was poor to moderate and accuracy was low. Applying this clinically, direct visualization of the articular surface may be necessary to ensure malreduction less than 5mm. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. External torsion in a proximal tibia and internal torsion in a distal tibia occur independently in varus osteoarthritic knees compared to healthy knees.

    PubMed

    Mochizuki, Tomoharu; Tanifuji, Osamu; Koga, Yoshio; Hata, Ryosuke; Mori, Takahiro; Nishino, Katsutoshi; Sato, Takashi; Kobayashi, Koichi; Omori, Go; Sakamoto, Makoto; Tanabe, Yuji; Endo, Naoto

    2017-05-01

    The relative torsional angle of the distal tibia is dependent on a deformity of the proximal tibia, and it is a commonly used torsional parameter to describe deformities of the tibia; however, this parameter cannot show the location and direction of the torsional deformity in the entire tibia. This study aimed to identify the detailed deformity in the entire tibia via a coordinate system based on the diaphysis of the tibia by comparing varus osteoarthritic knees to healthy knees. In total, 61 limbs in 58 healthy subjects (age: 54 ± 18 years) and 55 limbs in 50 varus osteoarthritis (OA) subjects (age: 72 ± 7 years) were evaluated. The original coordinate system based on anatomic points only from the tibial diaphysis was established. The evaluation parameters were 1) the relative torsion in the distal tibia to the proximal tibia, 2) the proximal tibial torsion relative to the tibial diaphysis, and 3) the distal tibial torsion relative to the tibial diaphysis. The relative torsion in the distal tibia to the proximal tibia showed external torsion in both groups, while the external torsion was lower in the OA group than in the healthy group (p < 0.0001). The proximal tibial torsion relative to the tibial diaphysis had a higher external torsion in the OA group (p = 0.012), and the distal tibial torsion relative to the tibial diaphysis had a higher internal torsion in the OA group (p = 0.004) in comparison to the healthy group. The reverse torsional deformity, showing a higher external torsion in the proximal tibia and a higher internal torsion in the distal tibia, occurred independently in the OA group in comparison to the healthy group. Clinically, this finding may prove to be a pathogenic factor in varus osteoarthritic knees. Level Ⅲ. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  19. Additive fiber-cerclages in proximal humeral fractures stabilized by locking plates

    PubMed Central

    Hurschler, Christof; Rech, Louise; Vosshenrich, Rolf; Lill, Helmut

    2009-01-01

    Background and purpose The effect of additive fiber-cerclages in proximal humeral fractures stabilized by locking plates on fracture stabilization and rotator cuff function is unclear. Here it was assessed in a human cadaver study. Methods 24 paired human shoulder specimens were harvested from median 77-year-old (range 66–85) female donors. An unstable 3-part fracture model with an intact rotator cuff was developed. 1 specimen of each pair received an additive fiber-cerclage of the rotator cuff after plate fixation, and the other one received a plate fixation without an additive fiber-cerclage. Force-controlled hydraulic cylinders were used to simulate physiological rotator cuff tension, while a robot-assisted shoulder simulator performed 4 relevant cases of load: (1) axial loading at 0°, (2) glenohumeral abduction at 60°, (3) internal rotation at 0° abduction, and (4) external rotation at 0° abduction, and imitated hanging arm weight during loading without affecting joint kinematics. A 3-dimensional real-time interfragmentary motion analysis was done in fracture gaps between the greater tuberosity and the head, as well as subcapital. The capacity of the rotator cuff to strain was analyzed with an optical system. Results Interfragmentary motion was similar between the groups with and without fiber-cerclages, in both fracture gaps and in any of the cases of load. Cerclages did not impair the capacity of the rotator cuff to strain. Interpretation Provided that unstable 3-part fractures are reduced and stabilized anatomically by a locking plate, additive fiber-cerclages do not reduce interfragmentary motion. Additive fiber-cerclages may be necessary in locking plate osteosyntheses of multiple-fractured greater tuberosities or lesser tuberosity fractures that cannot be fixed sufficiently by the plate. PMID:19562564

  20. [Ender nailing in fractures of the proximal femur. II. Analysis of our cohort].

    PubMed

    Bartonícek, J

    1989-12-01

    The work presents the analysis of the group of 172 patients with the fracture of the proximal femur treated by the technique of Ender nailing between June 1985 and December 1988. The group comprised 45 male (26 per cent) and 127 female (74 per cent) patients. Their average age was 76 years (ranging from 20 to 97 years of age) out of which 75 per cent of patients were older than 70 years and 40 per cent older than 80 years. Indication of Ender nailing in patients under 60 years of age we consider exceptional. In our group we operated on in total 14 patients under 60 years of age (ranging from 20 to 57 years of age) and namely in case of the comminuted type of fracture increased risk of infection or serious total condition. The whole group was operated on by 21 variously experienced surgeons. 147 operations were performed in the general anesthesia and 25 in the epidural one. The fractures of the proximal femur were divided into basicervical--10 (6 per cent), stable pertrochanteric 96 (56 per cent), unstable pertrochanteric--38 (22 per cent), per-subtrochanteric--19 (11 per cent) and subtrochanteric--9 (5 per cent). For the objective evaluation we compared our classification of the fracture of the trochanteric part with these of Evens, Kyle and Jensen. For stable fractures we considered the types I and II according to Kyle, for unstable the type III of Kyle classification. Per-subtrochanteric fractures (Kyle IV) we singled out for their seriousness as a separate group of unstable pertrochanteric fractures. Almost the same spectrum of fractures was in the group of 108 patients in which we evaluated longterm results. The minimum observence period was 3 months the mean period 6.3 months. Almost all patients from this group were followed up until complete healing. The mean duration of operation was 52 minutes, the mean duration of anesthesia was 81 minutes and the duration of X-ray exposure was 2.6 minutes. These data were calculated also for individual types of fractures

  1. Radiographic Investigation of the Distal Extension of Fractures Into the Articular Surface of the Tibia (The RIDEFAST Study).

    PubMed

    Marchand, Lucas S; Rane, Ajinkya A; Working, Zachary M; Jacobson, Lance G; Kubiak, Erik N; Higgins, Thomas F; Rothberg, David L

    2017-12-01

    To determine whether radiographic measurements are predictive of involvement of the distal tibia articular surface in tibial shaft fractures. Retrospective review. Academic Level-I trauma hospital. Two-hundred seventeen patients with tibial shaft fractures distal to the isthmus (OTA/AO: 42-A1-3; 42-B1-3; 42-C1-3; and 43-A1-3). Analysis of anteroposterior (AP) and lateral radiographs. The following parameters were measured: (1) angle between the predominant fracture line and the plane of the tibial plafond (α-angle), (2) length of the shaft fracture, (3) distance from the most inferior extent of the shaft fracture to the tibial plafond (DTP), (4) width of the tibial plafond, (5) width of the tibial isthmus, (6) ratio of fracture length to DTP (FTP), and (7) fibular fracture distance. Distal intra-articular involvement (DIA). A total of 217 patients were identified, 56 (26%) with DIA. The FTP ratio as measured on both the AP (odds ratio: 8.20, confidence interval, 4.26-17.22, P < 0.0001) and lateral radiographs (10.00, 4.78-23.23, <0.0001) was the most effective screening measurement for DIA. AP and lateral FTP ratios of 0.224 and 0.255, respectively, achieved a negative predictive value of 100%, eliminating the need for computed tomography in 16%-23% of injuries. Involvement of the distal articular surface in patients with distal tibial shaft fractures is significantly associated with fracture geometry and pattern. The FTP ratio may be used as an effective screening tool to rule out of intra-articular involvement. Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  2. An Incidental Finding of a Talonavicular and Talocalcaneal Joint Coalition After a Tibial Pilon Fracture: A Case Report.

    PubMed

    Godoy, Heidi M; Micciche, Mark J

    It has been proposed that patients with talocalcaneal and talonavicular coalitions have decreased ankle joint range of motion. It has also been reported that rotational forces regularly absorbed by the talocalcaneal joint are transferred to the ankle joint in patients with coalitions, increasing the stress on the ankle joint after trauma. To the best of our knowledge, only 1 reported study has detailed the increased stress placed on the ankle joint secondary to a coalition. We present a case study of a 53-year-old female who experienced a traumatic fall and subsequent right ankle fracture. Advanced imaging studies revealed a comminuted tibial pilon fracture and talocalcaneal and talonavicular joint coalitions. She underwent open reduction and internal fixation for treatment of the fracture, and the coalitions were not treated because they were asymptomatic. She was kept non-weightbearing for 6 weeks postoperatively and was returned to a regular sneaker at 10 weeks postoperatively. The postoperative films revealed stable intact fixation and pain-free gait with no increased restriction in her ankle joint range of motion. The hardware was removed at 13 months postoperatively. She had not experienced increased pain or arthritic changes at 15 months postoperatively. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Fatigue Failure in Extra-Articular Proximal Tibia Fractures: Locking Intramedullary Nail Versus Double Locking Plates-A Biomechanical Study.

    PubMed

    Kandemir, Utku; Herfat, Safa; Herzog, Mary; Viscogliosi, Paul; Pekmezci, Murat

    2017-02-01

    The goal of this study is to compare the fatigue strength of a locking intramedullary nail (LN) construct with a double locking plate (DLP) construct in comminuted proximal extra-articular tibia fractures. Eight pairs of fresh frozen cadaveric tibias with low bone mineral density [age: 80 ± 7 (SD) years, T-score: -2.3 ± 1.2] were used. One tibia from each pair was fixed with LN, whereas the contralateral side was fixed with DLP for complex extra-articular multifragmentary metaphyseal fractures (simulating OTA 41-A3.3). Specimens were cyclically loaded under compression simulating single-leg stance by staircase method out to 260,000 cycles. Every 2500 cycles, localized gap displacements were measured with a 3D motion tracking system, and x-ray images of the proximal tibia were acquired. To allow for mechanical settling, initial metrics were calculated at 2500 cycles. The 2 groups were compared regarding initial construct stiffness, initial medial and lateral gap displacements, stiffness at 30,000 cycles, medial and lateral gap displacements at 30,000 cycles, failure load, number of cycles to failure, and failure mode. Failure metrics were reported for initial and catastrophic failures. DLP constructs exhibited higher initial stiffness and stiffness at 30,000 cycles compared with LN constructs (P < 0.03). There were no significant differences between groups for loads at failure or cycles to failure. For the fixation of extra-articular proximal tibia fractures, a LN provides a similar fatigue performance to double locked plates. The locked nail could be safely used for fixation of proximal tibia fractures with the advantage of limited extramedullary soft tissue damage.

  4. Treatment of Patellar Lower Pole Fracture with Modified Titanium Cable Tension Band Plus Patellar Tibial Tunnel Steel "8" Reduction Band.

    PubMed

    Li, Jiaming; Wang, Decheng; He, Zhiliang; Shi, Hao

    2018-01-08

    To determine the efficacy of modified titanium tension band plus patellar tendon tunnel steel 8 "reduction band" versus titanium cable tension band fixation for the treatment of patellar lower pole fracture. 58 patients with lower patella fracture were enrolled in this study, including 30 patients treated with modified titanium cable tension band plus patellar tibial tunnel wire "8" tension band internal fixation (modified group), and 28 patients with titanium cable tension band fixation. All patients were followed up for 9∼15 months with an average of 11.6 months. Knee flexion was significantly improved in the modified group than in the titanium cable tension band group (111.33 ± 13 degrees versus 98.21 ± 21.70 degrees, P = 0.004). The fracture healing time showed no significant difference. At the end of the follow-up, the improvement excellent rate was 93.33% in the modified group, and 82.14% in the titanium cable tension band group. Titanium cable tension band internal fixation loosening was found in 2 cases, including 1 case of treatment by two surgeries without loose internal fixation. The modified titanium cable tension band with "8" tension band fixation showed better efficacy for lower patella fractures than titanium cable tension band fixation.

  5. Tibial dyschondroplasia associated proteomic changes in chicken growth plate cartilage

    USDA-ARS?s Scientific Manuscript database

    Tibial dyschondroplasia (TD) is a poultry leg problem that affects the proximal growth plate of tibia preventing its transition to bone. To understand the disease-induced proteomic changes we compared the protein extracts of cartilage from normal and TD- affected growth plates. TD was induced by fe...

  6. [Treatment of fractures of proximal phalanx of fingers by Eiffel Tower percutaneous pinning method. A review of 45 cases].

    PubMed

    Chbani, B; Amar, M F; Loudyi, D; Boutayeb, F

    2010-04-01

    The authors report in the treatment of fractures of the proximal phalanx of the fingers, the use of Eiffel Tower pinning, a relatively simple method, fast and stable, associated to a protection and early rehabilitation. The objective of this method is to offer to the patient a pollici-digital grip. Our study is a retrospective study of 45 patients treated for fractures of the proximal phalanx of the fingers by percutaneous pinning according to Eiffel Tower method. We detail this simple and economic technique and examine the functional and radiological results of this series of patients. The amplitude of the active total motion of the proximal interphalangeal joint is on average 94.16 degrees (78.5 % of the normal active mobility of the proximal interphalangeal joint), and the amplitude of the active total motion of the metacarpo-phalangeal joint is on average 90.05 degrees (75 % of the normal active mobility of the metacarpo-phalangeal joint). Copyright 2010 Elsevier Masson SAS. All rights reserved.

  7. Arthroscopic pullout repair of a complete radial tear of the tibial attachment site of the medial meniscus posterior horn.

    PubMed

    Kim, Young-Mo; Rhee, Kwang-Jin; Lee, June-Kyu; Hwang, Deuk-Soo; Yang, Jun-Young; Kim, Sung-Jae

    2006-07-01

    We developed an effective arthroscopic pullout technique for repairing complete radial tears of the tibial attachment site of the medial meniscus posterior horn (MMPH). In our technique, the torn meniscus is reattached to the tibial plateau immediately medial or anteromedial to the posterior cruciate ligament (PCL) using two No. 2 Ethibond sutures (Ethicon, Somerville, NJ). After a complete radial tear of the tibial attachment site of the MMPH and its reparability were confirmed, using a Caspari suture loaded with a suture shuttle, one No. 2 Ethibond suture is placed through the meniscus, through the red-red zone, 3 to 5 mm medial to the torn edge of the MMPH, and the other is passed through the meniscocapsular junction 3 to 5 mm medial to the torn edge of the meniscus. Then, a tibial tunnel, 5-mm in diameter, is made from the anteromedial aspect of the proximal tibia to the previously prepared tibial plateau, immediately medial or anteromedial to the PCL, and the two No. 2 Ethibond sutures are pulled out through the tibial tunnel and then fixed to the proximal tibia using a 3.5-mm cortical screw and washer. Firm reattachment of the torn meniscus was confirmed arthroscopically.

  8. The management of open tibial fractures in children: a retrospective case series of eight years' experience of 61 cases at a paediatric specialist centre.

    PubMed

    Nandra, R S; Wu, F; Gaffey, A; Bache, C E

    2017-04-01

    Following the introduction of national standards in 2009, most major paediatric trauma is now triaged to specialist units offering combined orthopaedic and plastic surgical expertise. We investigated the management of open tibia fractures at a paediatric trauma centre, primarily reporting the risk of infection and rate of union. A retrospective review was performed on 61 children who between 2007 and 2015 presented with an open tibia fracture. Their mean age was nine years (2 to 16) and the median follow-up was ten months (interquartile range 5 to 18). Management involved IV antibiotics, early debridement and combined treatment of the skeletal and soft-tissue injuries in line with standards proposed by the British Orthopaedic Association. There were 36 diaphyseal fractures and 25 distal tibial fractures. Of the distal fractures, eight involved the physis. Motor vehicle collisions accounted for two thirds of the injuries and 38 patients (62%) arrived outside of normal working hours. The initial method of stabilisation comprised: casting in nine cases (15%); elastic nailing in 19 (31%); Kirschner (K)-wiring in 13 (21%); intramedullary nailing in one (2%); open reduction and plate fixation in four (7%); and external fixation in 15 (25%). Wound management comprised: primary wound closure in 24 (39%), delayed primary closure in 11 (18%), split skin graft (SSG) in eight (13%), local flap with SSG in 17 (28%) and a free flap in one. A total of 43 fractures (70%) were Gustilo-Anderson grade III. There were four superficial (6.6%) and three (4.9%) deep infections. Two deep infections occurred following open reduction and plate fixation and the third after K-wire fixation of a distal fracture. No patient who underwent primary wound closure developed an infection. All the fractures united, although nine patients required revision of a mono-lateral to circular frame for delayed union (two) or for altered alignment or length (seven). The mean time to union was two weeks longer

  9. Multifocal humeral fractures.

    PubMed

    Maresca, A; Pascarella, R; Bettuzzi, C; Amendola, L; Politano, R; Fantasia, R; Del Torto, M

    2014-02-01

    Multifocal humeral fractures are extremely rare. These may affect the neck and the shaft, the shaft alone, or the diaphysis and the distal humerus. There is no classification of these fractures in the literature. From 2004 to 2010, 717 patients with humeral fracture were treated surgically at our department. Thirty-five patients presented with an associated fracture of the proximal and diaphyseal humerus: synthesis was performed with plate and screws in 34 patients, and the remaining patient had an open fracture that was treated with an external fixator. Mean follow-up was 3 years and 3 months. A classification is proposed in which type A fractures are those affecting the proximal and the humeral shaft, type B the diaphysis alone, and type C the diaphysis in association with the distal humerus. Type A fractures are then divided into three subgroups: A-I, undisplaced fracture of the proximal humerus and displaced shaft fracture; A-II: displaced fracture of the proximal and humeral shaft; and A-III: multifragmentary fracture affecting the proximal humerus and extending to the diaphysis. Multifocal humeral fractures are very rare and little described in the literature, both for classification and treatment. The AO classification describes bifocal fracture of the humeral diaphysis, type B and C. The classification suggested in this article mainly concerns fractures involving the proximal and humeral shaft. A simple classification of multifocal fractures is suggested to help the surgeon choose the most suitable type of synthesis for surgical treatment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Review of fixation techniques for the four-part fractured proximal humerus in hemiarthroplasty

    PubMed Central

    2011-01-01

    Introduction The clinical outcome of hemiarthroplasty for proximal humeral fractures is not satisfactory. Secondary fragment dislocation may prevent bone integration; the primary stability by a fixation technique is therefore needed to accomplish tuberosity healing. Present technical comparison of surgical fixation techniques reveals the state-of-the-art approach and highlights promising techniques for enhanced stability. Method A classification of available fixation techniques for three- and four part fractures was done. The placement of sutures and cables was described on the basis of anatomical landmarks such as the rotator cuff tendon insertions, the bicipital groove and the surgical neck. Groups with similar properties were categorized. Results Materials used for fragment fixation include heavy braided sutures and/or metallic cables, which are passed through drilling holes in the bone fragments. The classification resulted in four distinct groups: A: both tuberosities and shaft are fixed together by one suture, B: single tuberosities are independently connected to the shaft and among each other, C: metallic cables are used in addition to the sutures and D: the fragments are connected by short stitches, close to the fragment borderlines. Conclusions A plurality of techniques for the reconstruction of a fractured proximal humerus is found. The categorisation into similar strategies provides a broad overview of present techniques and supports a further development of optimized techniques. Prospective studies are necessary to correlate the technique with the clinical outcome. PMID:21762540

  11. Sensitivity and specificity of CT- and MRI-scanning in evaluation of occult fracture of the proximal femur.

    PubMed

    Haubro, M; Stougaard, C; Torfing, T; Overgaard, S

    2015-08-01

    To estimate sensitivity and specificity of CT and MRI examinations in patients with fractures of the proximal femur. To determine the interobserver agreement of the modalities among a senior consulting radiologist, a resident in radiology and a resident in orthopaedics surgery. 67 patients (27 males, 40 females, mean age 80.5) seen in the emergency room with hip pain after fall, inability to stand and a primary X-ray without fracture were evaluated with both CT and MRI. The images were analysed by a senior consulting musculoskeletal radiologist, a resident in radiology and a resident in orthopaedic surgery. Sensitivity and specificity were estimated with MRI as the golden standard. Kappa value was used to assess level of agreement in both MRI and CT finding. 15 fractures of the proximal femur were found (7 intertrochanteric-, 3 femoral neck and 5 fractures of the greater trochanter). Two fractures were not identified by CT and four changed fracture location. Among those, three patients underwent surgery. Sensitivity of CT was 0.87; 95% CI [0.60; 0.98]. Kappa for interobserver agreement for CT were 0.46; 95% CI [0.23; 0.76] and 0.67; 95% CI [0.42; 0.90]. For MRI 0.67; 95% CI [0.43; 0.91] and 0.69; 95% CI [0.45; 0.92]. MRI was observed to have a higher diagnostic accuracy than CT in detecting occult fractures of the hip. Interobserver analysis showed high kappa values corresponding substantial agreement in both CT and MRI. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. The epidemiology of fractures in infants--Which accidents are preventable?

    PubMed

    Wegmann, Helmut; Orendi, Ingrid; Singer, Georg; Eberl, Robert; Castellani, Christoph; Schalamon, Johannes; Till, Holger

    2016-01-01

    In children, fractures have a huge impact on the health care system. In order to develop effective prevention strategies exact knowledge about the epidemiology of fractures is mandatory. This study aims to describe clinical and epidemiological data of fractures diagnosed in infants. A retrospective analysis of all infants (children<1 year of age) presenting with fractures in an 11 years period (2001-2011) was performed. Information was obtained regarding the location of the fractures, sites of the accident, circumstances and mechanisms of injury and post-injury care. 248 infants (54% male, 46% female) with a mean age of 7 months presented with 253 fractures. In more than half of the cases skull fractures were diagnosed (n=151, 61%). Most frequently the accidents causing fractures happened at home (67%). Falls from the changing table, from the arm of the care-giver and out of bed were most commonly encountered (n=92, 37%). While the majority of skull fractures was caused from falls out of different heights, external impacts tended to lead to fractures of the extremities. 6 patients (2%) were victims of maltreatment and sustained 10 fractures (2 skull fractures, 4 proximal humeral fractures, 2 rib fractures, and 2 tibial fractures). Falls from the changing table, the arms of the caregivers and out of bed caused the majority of fractures (especially skull fracture) in infants. Therefore, awareness campaigns and prevention strategies should focus on these mechanisms of accident in order to decrease the rate of fractures in infants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Development and Validation of an Instrument to Predict Functional Recovery in Tibial Fracture Patients: The Somatic Pre-Occupation and Coping (SPOC) Questionnaire

    PubMed Central

    Busse, Jason W.; Bhandari, Mohit; Guyatt, Gordon H.; Heels-Ansdell, Diane; Kulkarni, Abhaya V.; Mandel, Scott; Sanders, David; Schemitsch, Emil; Swiontkowski, Marc; Tornetta, Paul; Wai, Eugene; Walter, Stephen D.

    2011-01-01

    Objective To explore the role of patients’ beliefs in their likelihood of recovery from severe physical trauma. Methods We developed and validated an instrument designed to capture the impact of patients’ beliefs on functional recovery from injury; the Somatic Pre-occupation and Coping (SPOC) questionnaire. At 6-weeks post-surgical fixation, we administered the SPOC questionnaire to 359 consecutive patients with operatively managed tibial shaft fractures. We constructed multivariable regression models to explore the association between SPOC scores and functional outcome at 1-year, as measured by return to work and short form-36 (SF-36) physical component summary (PCS) and mental component summary (MCS) scores. Results In our adjusted multivariable regression models that included pre-injury SF-36 scores, SPOC scores at 6-weeks post-surgery accounted for 18% of the variation in SF-36 PCS scores and 18% of SF-36 MCS scores at 1-year. In both models, 6-week SPOC scores were a far more powerful predictor of functional recovery than age, gender, fracture type, smoking status, or the presence of multi-trauma. Our adjusted analysis found that for each 14 point increment in SPOC score at 6-weeks (14 chosen on the basis of half a standard deviation of the mean SPOC score) the odds of returning to work at 1-year decreased by 40% (odds ratio = 0.60; 95% CI = 0.50 to 0.73). Conclusion The SPOC questionnaire is a valid measurement of illness beliefs in tibial fracture patients and is highly predictive of their long-term functional recovery. Future research should explore if these results extend to other trauma populations and if modification of unhelpful illness beliefs is feasible and would result in improved functional outcomes. PMID:22011635

  14. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.

    PubMed

    Huang, Xiaowei; Zhi, Zhongzheng; Yu, Baoqing; Chen, Fancheng

    2015-11-25

    The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P < 0.001) smaller than that of the screw fixation system. The maximal value of displacement (sum) in the plate-screw fixation system was 2.46 mm, which was lower than that in the screw fixation system (3.91 mm). The peak stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.

  15. The role of medial meniscus posterior root tear and proximal tibial morphology in the development of spontaneous osteonecrosis and osteoarthritis of the knee.

    PubMed

    Yamagami, Ryota; Taketomi, Shuji; Inui, Hiroshi; Tahara, Keitaro; Tanaka, Sakae

    2017-03-01

    Medial meniscus posterior root tear (MMPRT) has been reported to play a key role in the development of spontaneous osteonecrosis of the knee (SONK) and osteoarthritis (OA) of the knee. However, little is known about the differences in the development of SONK and OA after MMPRT. The purpose of this study was to investigate the factors contributing to the development of these conditions. We evaluated the existence of MMPRT and the extent of medial meniscal extrusion in preoperative magnetic resonance images and proximal tibial morphology in radiographs of 45 patients with SONK and 104 patients with OA who underwent knee surgery. There were no significant differences in age, gender, height, weight, and body mass index between the two groups. The incidence of MMPRT and the mean posterior tibial slope (PTS) were significantly higher in SONK than in OA patients (62.2% versus 34.3%, P=0.002, and 12.8° versus 10.5°, P<0.001, respectively). The mean extent of meniscal extrusion was larger in OA than in SONK patients (7.5mm versus 5.3mm, P<0.001). The mean tibial varus angle was 4.8° in SONK and 5.4° in OA, with no significant difference between the two (P=0.088). Multivariable logistic regression analysis showed that compared with OA, SONK was more closely associated with the existence of MMPRT and had a smaller extent of medial meniscus extrusion and higher PTS. MMRPT and higher PTS were more closely associated with the development of SONK than with that of OA. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. The prediction of cyclic proximal humerus fracture fixation failure by various bone density measures.

    PubMed

    Varga, Peter; Grünwald, Leonard; Windolf, Markus

    2018-02-22

    Fixation of osteoporotic proximal humerus fractures has remained challenging, but may be improved by careful pre-operative planning. The aim of this study was to investigate how well the failure of locking plate fixation of osteoporotic proximal humerus fractures can be predicted by bone density measures assessed with currently available clinical imaging (realistic case) and a higher resolution and quality modality (theoretical best-case). Various density measures were correlated to experimentally assessed number of cycles to construct failure of plated unstable low-density proximal humerus fractures (N = 18). The influence of density evaluation technique was investigated by comparing local (peri-implant) versus global evaluation regions; HR-pQCT-based versus clinical QCT-based image data; ipsilateral versus contralateral side; and bone mineral content (BMC) versus bone mineral density (BMD). All investigated density measures were significantly correlated with the experimental cycles to failure. The best performing clinically feasible parameter was the QCT-based BMC of the contralateral articular cap region, providing significantly better correlation (R 2  = 0.53) compared to a previously proposed clinical density measure (R 2  = 0.30). BMC had consistently, but not significantly stronger correlations with failure than BMD. The overall best results were obtained with the ipsilateral HR-pQCT-based local BMC (R 2  = 0.74) that may be used for implant optimization. Strong correlations were found between the corresponding density measures of the two CT image sources, as well as between the two sides. Future studies should investigate if BMC of the contralateral articular cap region could provide improved prediction of clinical fixation failure compared to previously proposed measures. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Value of lateral blood pool imaging in patients with suspected stress fractures of the tibia.

    PubMed

    Mohan, Hosahalli K; Clarke, Susan E M; Centenara, Martin; Lucarelli, Amanda; Baron, Daniel; Fogelman, Ignac

    2011-03-01

    To critically evaluate the use of lateral blood pool imaging in athletes with lower limb pain and with a clinical suspicion of stress fracture. Two experienced nuclear medicine physicians evaluated 3-phase bone scans using 99mTc-methylene diphosphonate performed in 50 consecutive patients referred from a specialist sports injury clinic for suspected tibial stress fracture. The vascularity to the tibia as seen on the blood pool (second phase) images in the anterior/posterior views was compared with the lateral/medial view assessments. Stress fractures were presumed to be present when on the delayed images (third phase) there was a focal or fusiform area of increased tracer uptake involving the tibial cortex. Shin splints which are a recognized cause of lower limb pain in athletes mimicking stress fracture were diagnosed if increased tracer uptake was seen extending along the posterior tibial surface with no significant focal or fusiform area of uptake within this. Inter-reviewer agreement for the assessment of vascularity was also assessed using Cohen's Kappa scores. Twenty-four stress fractures in 24 patients and 66 shin splints in 40 patients were diagnosed. In 18 patients stress fracture and shin splints coexisted. In 10 patients no tibial pathology was identified. Of the 24 patients diagnosed with stress fractures, lateral/medial blood pool imaging was superior in the assessment of blood pool activity (P < 0.001) identifying increased vascularity in 21 cases compared with the anterior/posterior views positive in only 11 cases. The inter-reviewer agreement was near perfect for lateral/medial views, κ = 0.86 while very good for anterior/posterior views, κ = 0.68. In patients with suspected tibial stress fractures, lateral views of the tibia provide the optimal method for evaluation of vascularity. Prospective studies with quantitative or semi-quantitative assessment of skeletal vascularity could provide supplementary information relating to the pathophysiology

  18. Comparison of Percutaneous Cementoplasty with and Without Interventional Internal Fixation for Impending Malignant Pathological Fracture of the Proximal Femur

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tian, Qing-Hua, E-mail: ddqinghua-tian@163.com; He, Cheng-Jian, E-mail: tianhechengjian@163.com; Wu, Chun-Gen, E-mail: 649514608@qq.com

    PurposeTo compare the efficacy of percutaneous cementoplasty (PCP) with and without interventional internal fixation (IIF) on malignant impending pathological fracture of proximal femur.MethodsA total of 40 patients with malignant impending pathological fracture of proximal femur were selected for PCP and IIF (n = 19, group A) or PCP alone (n = 21, group B) in this non-randomized prospective study. Bone puncture needles were inserted into the proximal femur, followed by sequential installation of the modified trocar inner needles through the puncture needle sheath. Then, 15–45 ml cement was injected into the femur lesion.ResultsThe overall excellent and good pain relief rate during follow-ups were significantly highermore » in group A than that in group B (89 vs. 57 %, P = 0.034). The average change of VAS, ODI, KPS, and EFES in group A were significantly higher than those in group B at 1-, 3-, 6-month, 1-year (P < 0.05). Meanwhile, The stability of the treated femur was significantly higher in group A than that in group B (P < 0.05).ConclusionPCP and IIF were not only a safe and effective procedure, but resulted in greater pain relief, bone consolidation, and also reduced the risk of fracture than the currently recommended approach of PCP done on malignant proximal femoral tumor.« less

  19. Fracture prevention by prophylactic femoroplasty of the proximal femur--metallic compared with cemented augmentation.

    PubMed

    Springorum, Hans-Robert; Gebauer, Matthias; Mehrl, Alexander; Stark, Olaf; Craiovan, Benjamin; Püschel, Klaus; Amling, Michael; Grifka, Joachim; Beckmann, Johannes

    2014-07-01

    To compare 2 different femoral neck augmentation techniques at improving the mechanical strength of the femoral neck. Twenty pairs of human cadaveric femora were randomly divided into 2 groups. In 1 group, the femora were augmented with a steel spiral; the other group with the cemented technique. The untreated contralateral side served as an intraindividual control. Fracture strength was evaluated using an established biomechanical testing scenario mimicking a fall on the greater trochanter (Hayes fall). The peak load to failure was significantly higher in the steel spiral group (P = 0.0024) and in the cemented group (P = 0.001) compared with the intraindividual controls. The peak load to failure showed a median of 3167 N (1825-5230 N) in the spiral group and 2485 N (1066-4395 N) in the spiral control group. The peak load to failure in the cemented group was 3698 N (SD ± 1249 N) compared with 2763 N (SD ± 1335 N) in the cement control group. Furthermore, fracture displacement was clearly reduced in the steel spiral group. Femoral augmentations using steel spirals or cement-based femoroplasty are technically feasible procedures. Our results demonstrate that a prophylactic reinforced proximal femur has higher strength when compared with the untreated contralateral limb. Prophylactic augmentation has potential to become an auxiliary treatment option to protect the osteoporotic proximal femur against fracture.

  20. The risk of sacrificing the PCL in cruciate retaining total knee arthroplasty and the relationship to the sagittal inclination of the tibial plateau.

    PubMed

    Sessa, Pasquale; Fioravanti, Giulio; Giannicola, Giuseppe; Cinotti, Gianluca

    2015-01-01

    In cruciate retaining total knee arthroplasty (TKA), a partial avulsion of PCL may occur when en-bloc tibial osteotomy is performed. We evaluated the effects of a tibial cut performed with different degrees of posterior slope on PCL insertion and whether the results are affected by the sagittal inclination of the patient's tibial plateau. We selected 83 MRIs of knees showing mild or no degenerative changes. The effects of a simulated tibial cut performed with a posterior slope of 0°, 3°, 5° and parallel to the patient's tibial plateau inclination on PCL insertion in the proximal tibia were investigated. The results were correlated with the degree of posterior inclination of the tibial plateau. Every angle we used for the tibial cut caused a PCL avulsion greater than 50%. The percentage of PCL avulsion significantly increased with increasing the posterior slope of the tibial cut. Patients with sagittal tibial plateau inclination <5° showed greater PCL avulsion than those with sagittal inclination >8°. Most of the PCL insertion is likely to be sacrificed when resection of the proximal tibia is performed en-block. The risk of PCL avulsion is reduced in patients showing a marked posterior inclination of the tibial plateau, but even in this group of patients a surgical technique aimed at sparing most of the PCL insertion is necessary. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. When are CT angiograms indicated for patients with lower extremity fractures? A review of 275 extremities.

    PubMed

    Monazzam, Shafagh; Goodell, Parker B; Salcedo, Edgardo S; Nelson, Sandahl H; Wolinsky, Philip R

    2017-01-01

    Computed tomography angiogram (CTA) is frequently utilized to detect vascular injuries even without examination findings indicating a vascular injury. We had the following hypotheses: (1) a CTA for lower extremity fractures with no clinical signs of a vascular injury is not indicated, and (2) fracture location and pattern would correlate with the risk of a vascular injury. A retrospective review was conducted on patients who had an acute lower extremity fracture(s) and a CTA. Their charts were reviewed for multiple factors including the presence or absence of hard or soft signs of a vascular injury, soft tissue status, and fracture location/pattern. Every CTA radiology report was reviewed and any vascular intervention or amputation resulting from a vascular injury was recorded. Statistical analysis was performed. Of the 275 CTAs of fractured extremities reviewed, 80 (29%) had a positive CTA finding and 16 (6%) required treatment. A total of 109 (40%) of the extremities had no hard or soft signs; all had normal CTAs. Having at least one hard or soft sign was a significant risk factor for having a positive CTA. An open fracture, isolated proximal third fibula fracture, distal and shaft tibia fractures, and the presence of multiple fractures in one extremity were also associated with an increased risk for having a positive CTA. We found no evidence to support the routine use of CTAs to evaluate lower extremity fractures unless at least one hard or soft sign is present. The presence of an open fracture, distal tibia or tibial shaft fractures, multiple fractures in one extremity, and/or an isolated proximal third fibula fracture increases the risk of having a finding consistent with a vascular injury on a CTA. Only 6% of the cases required treatment, and all of them had diminished or absent distal pulses on presentation. Diagnostic test, level III.

  2. Minimally invasive fixation in tibial plateau fractures using an pre-operative and intra-operative real size 3D printing.

    PubMed

    Giannetti, Silvio; Bizzotto, Nicola; Stancati, Andrea; Santucci, Attilio

    2017-03-01

    The purpose of our study was to compare the outcome after minimally invasive reconstruction and internal fixation with and without the use of pre- and intra-operative real size 3D printing for patients with displaced tibial plateau fractures (TPFs). We prospectively followed up 40 consecutive adult patients with closed TPF who underwent surgical treatment of reconstruction of the tibial plateau with the use of minimally invasive fixation. Sixteen patients (group 1) were operated using a pre-operative and intra-operative real size 3D-model, while 24 patients (group 2) were operated without 3D-model printing, but using only pre-operative and intra-operative 3D Tc-scan images. The mean operating time was 148.2±15.9min for group 1 and 174.5±22.2min for group 2 (p=0.041). In addition, the mean intraoperative blood loss was less in group 1 (520mL) than in group 2 (546mL) (p=0.534). After discharge, all patients were followed up at 6 weeks, 12 weeks, 6 months, 1year and then every year post surgically and radiographic evaluation was carried out each time using clinical and radiological Rasmussen's score, with no significant differences between the two groups. Two patients (group 2) developed infection which resolved within 3 weeks after usage of antibiotics. Neither superficial nor deep infections were present in group 1. In all patients, no non-union occurred. No intraoperative, perioperative, or postoperative complications, such as loss of valgus correction, bone fractures, or metallic plate failures were detected at follow-up. In patients operated with the use of 3D-model printing, we found a significant reduction in surgical time. Moreover, the technique without a 3D-model increased the patient's and the surgeon's exposure to radiation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. A comprehensive update on current fixation options for two-part proximal humerus fractures: a biomechanical investigation.

    PubMed

    Yoon, Richard S; Dziadosz, Daniel; Porter, David A; Frank, Matthew A; Smith, Wade R; Liporace, Frank A

    2014-03-01

    Recent advancements in implant technology offer updated options for surgical management that have been rapidly adopted into clinical practice. The objective of this study is to biomechanically test and compare the current fixation options available for surgical fixation of two-part proximal humerus fractures and establish load to failure and stiffness values. Sixteen match-paired (32 total) fresh-frozen, cadaveric specimens were randomized to receive 1 of 4 fixation constructs following creation of an AO/OTA Type 11A3 (two-part) proximal humerus fractures. Fixation constructs tested consisted of 3.5 mm fixed angle plate (3.5-FAP), 4.5 mm fixed angle plate (4.5-FAP), humeral intramedullary nail (IMN), and a humeral intramedullary nail with a fixed angle blade (IMN-FAB). Specimen bone density was measured to ensure no adequate, non-osteoporotic bone. Constructs were tested for stiffness and ultimate load to failure and compared via one-way ANOVA analysis with subsequent post hoc Tukey HSD multiple group comparison statistical analysis. The IMN-FAB construct was significantly stiffer than the 3.5-FAP construct (123.8 vs. 23.9, p<0.0001), the 4.5-FAP construct (123.8 vs. 33.3, p<0.0001) and the IMN construct (123.8 vs. 60.1, p=0.005). The IMN-FAB construct reported a significantly higher load to failure than the 3.5-FAB construct (4667.3 N vs. 1756.9 N, p<0.0001), and the 4.5-FAP construct (4667.3 N vs. 2829.4 N, p=0.019, Table 2). The IMN construct had a significantly higher load to failure than the 3.5-FAP construct (3946.8 vs. 1756.9, p=0.001, Table 2). Biomechanical testing of modern fixation options for two-part proximal humerus fracture exhibited that the stiffest and highest load to failure construct was the IMN-FAB followed by the IMN, 3.5-FAP and then the 4.5-FAP constructs. However, prospective clinical trials with longer-term follow-up are required for definitive assessment of the ideal fixation construct for surgical management of two-part proximal humerus

  4. A prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures.

    PubMed

    Obremskey, William T; Cutrera, Norele; Kidd, Christopher M

    2017-03-01

    The purpose of this study was to determine optimal treatment of stable tibial shaft fractures using intramedullary nailing (IMN) or casting. We performed a multi-center prospective study cohort. Patients with stable tibia shaft fractures meeting Sarmiento's criteria (isolated closed fractures with less than 12 mm of shortening and 10° of angulation) were enrolled prospectively and treated with either a reamed IMN with static interlocking screws or closed reduction followed by long-leg casting. Both groups were weight bearing following surgery. Radiographs were taken until union, and range of motion of knee and ankle joints was assessed. Malalignment (>5°) and malunion (>10°) were determined. Functional outcome measures using short musculoskeletal assessment scores (SMFA) and a knee pain score were scheduled at 6 weeks, 3 months and 6 months. At 3 months, differences between the casting and IMN groups were noted in return to work (6/15 vs 3/17, P < 0.05); ankle dorsiflexion (7° vs 12°, P < 0.05); plantar flexion (28° vs 39°, P < 0.05); and SMFA domains of Dysfunction Index, Bother Index, daily activities, emotional status, and arm/hand function (P < 0.05). The SMFA mobility function demonstrated a significant trend (P = 0.065). At 6 months, malalignment was present in 3/15 in the casting group and in 1/17 in the IMN group (P = 0.02). Malunion was present in 1/15 in the cast group. One fracture in the casting group went on to nonunion and required late IMN placement at 7 months and eventually healed. There were no differences in ankle motion, SMFA scores, or return to work. There was no difference in knee pain between the groups as measured by VAS and Court-Brown pain scale at 6 months. Patients with stable tibia fractures treated with intramedullary nailing have improved clinical and functional outcomes at 3 months compared with those treated with casting, but there are no differences in any other outcome measure. Patients treated in a

  5. [Investigation of tibial bones of the rats exposed on board "Spacelab-2":histomorphometric analysis

    NASA Technical Reports Server (NTRS)

    Durnova, G. N.; Kaplanskii, A. S.; Morey-Holton, E. R.; Vorobeva, V. N.

    1996-01-01

    Proximal metaphyses of tibial bones from the Sprague-Dowly rats exposed in US dedicated space life sciences laboratory SLS-2 for 13-14 days and sacrificed on day 13 in microgravity and within 5 hours and 14 days following recovery were the subject of histological, histochemical, and histomorphometric analyses. After the 13-day flight of SLS-2 the rats showed initial signs of osteopenia in the spongy tissue of tibial bones, secondary spongiosis affected first. Resorption of the secondary spongiosis was consequent to enhanced resorption and inhibition of osteogenesis. In rats sacrificed within 5 hours of recovery manifestations of tibial osteopenia were more evident than in rats sacrificed during the flight. Spaceflight-induced changes in tibial spongiosis were reverse by character the amount of spongy bone was fully compensated and following 14 days of readaptation to the terrestrial gravity.

  6. Fixator-assisted medial tibial plateau elevation to treat severe Blount's disease: outcomes at maturity.

    PubMed

    Fitoussi, F; Ilharreborde, B; Lefevre, Y; Souchet, P; Presedo, A; Mazda, K; Penneçot, G F

    2011-04-01

    Severe forms of Blount's disease may be associated with medial tibial plateau (MTP) depression. Management should then take account of joint congruence, laxity, limb axis, torsional abnomality, leg length discrepancy (LLD) and eventual recurrence history. Eight knees (six patients) were managed in a single step comprising MTP elevation osteotomy, lateral epiphysiodesis and proximal tibia osteotomy to correct varus and rotational deformity. Fixation was achieved using an Ilizarov external fixator. Mean age was 10.5 years. Mean hip-knee-ankle (HKA) angle was 151°; distal femoral varus, 94°; metaphyseal-diaphyseal angle (MDA), 27°; and angle of depression of the medial tibial plateau (ADMTP), 42°. Predicted residual proximal tibial growth was 2.6 cm. At a mean 48 months' follow-up, results were good in six cases, medium in one and poor (due to incomplete lateral epiphysiodesis) in one. Mean lateral tibial torsion was 9° and final LLD 11 mm. Weight-bearing was resumed at 2 months, and the fixator was removed at 5.5 months postoperatively. At end of follow-up, mean HKA angle was 179.6°, MDA 7.3° and ADMTP 5.4°. This technically demanding procedure gave satisfactory results in terms of axes and congruence; longer term assessment remains needed. Level IV. Retrospective study. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  7. Optimizing finite element predictions of local subchondral bone structural stiffness using neural network-derived density-modulus relationships for proximal tibial subchondral cortical and trabecular bone.

    PubMed

    Nazemi, S Majid; Amini, Morteza; Kontulainen, Saija A; Milner, Jaques S; Holdsworth, David W; Masri, Bassam A; Wilson, David R; Johnston, James D

    2017-01-01

    Quantitative computed tomography based subject-specific finite element modeling has potential to clarify the role of subchondral bone alterations in knee osteoarthritis initiation, progression, and pain. However, it is unclear what density-modulus equation(s) should be applied with subchondral cortical and subchondral trabecular bone when constructing finite element models of the tibia. Using a novel approach applying neural networks, optimization, and back-calculation against in situ experimental testing results, the objective of this study was to identify subchondral-specific equations that optimized finite element predictions of local structural stiffness at the proximal tibial subchondral surface. Thirteen proximal tibial compartments were imaged via quantitative computed tomography. Imaged bone mineral density was converted to elastic moduli using multiple density-modulus equations (93 total variations) then mapped to corresponding finite element models. For each variation, root mean squared error was calculated between finite element prediction and in situ measured stiffness at 47 indentation sites. Resulting errors were used to train an artificial neural network, which provided an unlimited number of model variations, with corresponding error, for predicting stiffness at the subchondral bone surface. Nelder-Mead optimization was used to identify optimum density-modulus equations for predicting stiffness. Finite element modeling predicted 81% of experimental stiffness variance (with 10.5% error) using optimized equations for subchondral cortical and trabecular bone differentiated with a 0.5g/cm 3 density. In comparison with published density-modulus relationships, optimized equations offered improved predictions of local subchondral structural stiffness. Further research is needed with anisotropy inclusion, a smaller voxel size and de-blurring algorithms to improve predictions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Foot and ankle function after tibial overlengthening.

    PubMed

    Emara, Khaled M; Diab, Ramy Ahmed; El Ghazali, Sherif; Farouk, Amr; El Kersh, Mohamed Ahmed

    2014-01-01

    Lengthening the tibia more than 25% of its original length can be indicated for proximal femoral deficiency, poliomyelitis, or femoral infected nonunion. Such lengthening of the tibia can adversely affect the ankle or foot shape and function. The present study aimed to assess the effect of tibial lengthening of more than 25% of its original length on the foot and ankle shape and function compared with the preoperative condition. This was a retrospective study of 13 children with severe proximal focal femoral deficiency, Aitken classification type D, who had undergone limb lengthening from June 2000 to June 2008 using Ilizarov external fixators. The techniques used in tibial lengthening included lengthening without intramedullary rodding and lengthening over a nail. The foot assessment was done preoperatively, at fixator removal, and then annually for 3 years, documenting the range of motion and deformity of the ankle and subtalar joints and big toe and the navicular height, calcaneal pitch angle, and talo-first metatarsal angle. At fixator removal, all cases showed equinocavovarus deformity, with decreased ankle, subtalar, and big toe motion. The mean American Orthopedic Foot and Ankle Society score was significantly reduced. During follow-up, the range of motion, foot deformity, and American Orthopedic Foot and Ankle Society score improved, reaching nearly to the preoperative condition by 2 years of follow-up. The results of our study have shown that tibial overlengthening has an adverse effect on foot and ankle function. This effect was reversible in the patients included in the present study. Lengthening of more than 25% can be safely done after careful discussion with the patients and their families about the probable effects of lengthening on foot and ankle function. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Reverse total shoulder replacement for nonunion of a fracture of the proximal humerus.

    PubMed

    Zafra, M; Uceda, P; Flores, M; Carpintero, P

    2014-09-01

    Patients with pain and loss of shoulder function due to nonunion of a fracture of the proximal third of the humerus may benefit from reverse total shoulder replacement. This paper reports a prospective, multicentre study, involving three hospitals and three surgeons, of 35 patients (28 women, seven men) with a mean age of 69 years (46 to 83) who underwent a reverse total shoulder replacement for the treatment of nonunion of a fracture of the proximal humerus. Using Checchia's classification, nine nonunions were type I, eight as type II, 12 as type III and six as type IV. The mean follow-up was 51 months (24 to 99). Post-operatively, the patients had a significant decrease in pain (p < 0.001), and a significant improvement in flexion, abduction, external rotation and Constant score (p < 0.001), but not in internal rotation. A total of nine complications were recorded in seven patients: six dislocations, one glenoid loosening in a patient who had previously suffered dislocation, one transitory paresis of the axillary nerve and one infection. Reverse total shoulder replacement may lead to a significant reduction in pain, improvement in function and a high degree of satisfaction. However, the rate of complications, particularly dislocation, was high. ©2014 The British Editorial Society of Bone & Joint Surgery.

  10. Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study.

    PubMed

    Konya, Mehmet Nuri; Verim, Özgür

    2017-09-29

    Proximal femoral fracture rates are increasing due to osteoporosis and traffic accidents. Proximal femoral nails are routinely used in the treatment of these fractures in the proximal femur. To compare various combinations and to determine the ideal proximal lag screw position in pertrochanteric fractures (Arbeitsgemeinschaft für Osteosynthesefragen classification 31-A1) of the femur by using optimized finite element analysis. Biomechanical study. Computed tomography images of patients' right femurs were processed with Mimics. Afterwards a solid femur model was created with SolidWorks 2015 and transferred to ANSYS Workbench 16.0 for response surface optimization analysis which was carried out according to anterior-posterior (-10°proximal lag screw positions in the fracture region. The optimum position of the proximal lag screw was determined based on the von Mises stress values occurring on the fracture line. Initial analysis of the system was realized under the surgeon's normal positioning conditions (anterior-posterior, inferior-superior=0°; tip-apex distance=12 mm). The maximum and minimum (compression) von Mises stresses were found to be 438 MPa and 0.003 MPa, respectively, and risky stresses for the system occurred in the regions where the proximal lag screw passes through the proximal femoral nail hole, the small diameter portion of stem joints with a large diameter and lag screw mounts to the stem. The most suitable position of the proximal lag screw was found at the middle position of the tip-apex distance (20 mm) and femoral neck (anterior-posterior, inferior-superior=0°), according to von Mises compression stress values occurring on the fracture line. In our study, we couldn't find any correlation between proximal lag screw movement and tip-apex distance on stresses of the fracture surfaces, but the proximal lag screw

  11. Automated Measurement of Patient-Specific Tibial Slopes from MRI

    PubMed Central

    Amerinatanzi, Amirhesam; Summers, Rodney K.; Ahmadi, Kaveh; Goel, Vijay K.; Hewett, Timothy E.; Nyman, Edward

    2017-01-01

    Background: Multi-planar proximal tibial slopes may be associated with increased likelihood of osteoarthritis and anterior cruciate ligament injury, due in part to their role in checking the anterior-posterior stability of the knee. Established methods suffer repeatability limitations and lack computational efficiency for intuitive clinical adoption. The aims of this study were to develop a novel automated approach and to compare the repeatability and computational efficiency of the approach against previously established methods. Methods: Tibial slope geometries were obtained via MRI and measured using an automated Matlab-based approach. Data were compared for repeatability and evaluated for computational efficiency. Results: Mean lateral tibial slope (LTS) for females (7.2°) was greater than for males (1.66°). Mean LTS in the lateral concavity zone was greater for females (7.8° for females, 4.2° for males). Mean medial tibial slope (MTS) for females was greater (9.3° vs. 4.6°). Along the medial concavity zone, female subjects demonstrated greater MTS. Conclusion: The automated method was more repeatable and computationally efficient than previously identified methods and may aid in the clinical assessment of knee injury risk, inform surgical planning, and implant design efforts. PMID:28952547

  12. Novel management of distal tibial and fibular fractures with Acumed fibular nail and minimally invasive plating osteosynthesis technique: A case report.

    PubMed

    Wang, Tie-Jun; Ju, Wei-Na; Qi, Bao-Chang

    2017-03-01

    Anatomical characteristics, such as subcutaneous position and minimal muscle cover, contribute to the complexity of fractures of the distal third of the tibia and fibula. Severe damage to soft tissue and instability ensure high risk of delayed bone union and wound complications such as nonunion, infection, and necrosis. This case report discusses management in a 54-year-old woman who sustained fractures of the distal third of the left tibia and fibula, with damage to overlying soft tissue (swelling and blisters). Plating is accepted as the first choice for this type of fracture as it ensures accurate reduction and rigid fixation, but it increases the risk of complications. Closed fracture of the distal third of the left tibia and fibula (AO: 43-A3). After the swelling was alleviated, the patient underwent closed reduction and fixation with an Acumed fibular nail and minimally invasive plating osteosynthesis (MIPO), ensuring a smaller incision and minimal soft-tissue dissection. At the 1-year follow-up, the patient had recovered well and had regained satisfactory function in the treated limb. The Kofoed score of the left ankle was 95. Based on the experience from this case, the operation can be undertaken safely when the swelling has been alleviated. The minimal invasive technique represents the best approach. Considering the merits and good outcome in this case, we recommend the Acumed fibular nail and MIPO technique for treatment of distal tibial and fibular fractures.

  13. Three-column classification and Schatzker classification: a three- and two-dimensional computed tomography characterisation and analysis of tibial plateau fractures.

    PubMed

    Patange Subba Rao, Sheethal Prasad; Lewis, James; Haddad, Ziad; Paringe, Vishal; Mohanty, Khitish

    2014-10-01

    The aim of the study was to evaluate inter-observer reliability and intra-observer reproducibility between the three-column classification and Schatzker classification systems using 2D and 3D CT models. Fifty-two consecutive patients with tibial plateau fractures were evaluated by five orthopaedic surgeons. All patients were classified into Schatzker and three-column classification systems using x-rays and 2D and 3D CT images. The inter-observer reliability was evaluated in the first round and the intra-observer reliability was determined during the second round 2 weeks later. The average intra-observer reproducibility for the three-column classification was from substantial to excellent in all sub classifications, as compared with Schatzker classification. The inter-observer kappa values increased from substantial to excellent in three-column classification and to moderate in Schatzker classification The average values for three-column classification for all the categories are as follows: (I-III) k2D = 0.718, 95% CI 0.554-0.864, p < 0.0001 and average 3D = 0.874, 95% CI 0.754-0.890, p < 0.0001. For Schatzker classification system, the average values for all six categories are as follows: (I-VI) k2D = 0.536, 95% CI 0.365-0.685, p < 0.0001 and average k3D = 0.552 95% CI 0.405-0.700, p < 0.0001. The values are statistically significant. Statistically significant inter-observer values in both rounds were noted with the three-column classification, making it statistically an excellent agreement. The intra-observer reproducibility for the three-column classification improved as compared with the Schatzker classification. The three-column classification seems to be an effective way to characterise and classify fractures of tibial plateau.

  14. Reverse shoulder arthroplasty in 3 and 4 part proximal humeral fractures in patients aged more than 65 years: Results and complications.

    PubMed

    Villodre-Jiménez, J; Estrems-Díaz, V; Diranzo-García, J; Bru-Pomer, A

    The treatment of 3and 4 part proximal humeral fractures in elderly patients is still controversial. The frequent co-existence of poor quality bone and rotator cuff abnormalities in patients with multiple clinical conditions and with difficulties for physical rehabilitation leads to disappointing clinical results, even when the radiological images are acceptable. To evaluate the clinical, radiological, and functional results in patients over 65 years old with complex proximal humerus fractures treated with reverse shoulder arthroplasty. A prospective review was carried out on 30 patients (26 women and 4 men) with proximal humeral fractures treated with reverse shoulder arthroplasty in our department. The mean age was 74.9 years (SD=6.3), and the mean follow-up was 34.5 months (SD=19.3). Clinical and functional results were acceptable, with a mean forward flexion of 124° and a mean external rotation of 13°. The mean abbreviated Constant abbreviated score was 49.1 (SD=14.1), 27 (SD=6.3) in the UCLA scale, and 32.2 (SD=19.2) in the QuickDASH questionnaire. The large majority (80%) of the patients are pain free, and they do not need medication to do daily activities. The complication rate was 13.3%. We consider that reverse shoulder arthroplasty is a valid option to treat 3and 4 part proximal humeral fractures in elderly patients. The surgical goals should include the anatomical reconstruction of the tuberosities, avoiding enlargement of the operated arm greater than 2cm. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. The factors influencing the decision making of operative treatment for proximal humeral fractures.

    PubMed

    Hageman, Michiel G J S; Jayakumar, Prakash; King, John D; Guitton, Thierry G; Doornberg, Job N; Ring, David

    2015-01-01

    The factors influencing the decision making of operative treatment for fractures of the proximal humerus are debated. We hypothesized that there is no difference in treatment recommendations between surgeons shown radiographs alone and those shown radiographs and patient information. Secondarily, we addressed (1) factors associated with a recommendation for operative treatment, (2) factors associated with recommendation for arthroplasty, (3) concordance with the recommendations of the treating surgeons, and (4) factors affecting the inter-rater reliability of treatment recommendations. A total of 238 surgeons of the Science of Variation Group rated 40 radiographs of patients with proximal humerus fractures. Participants were randomized to receive information about the patient and mechanism of injury. The response variables included the choice of treatment (operative vs nonoperative) and the percentage of matches with the actual treatment. Participants who received patient information recommended operative treatment less than those who received no information. The patient information that had the greatest influence on treatment recommendations included age (55%) and fracture mechanism (32%). The only other factor associated with a recommendation for operative treatment was region of practice. There was no significant difference between participants who were and were not provided with information regarding agreement with the actual treatment (operative vs nonoperative) provided by the treating surgeon. Patient information-older age in particular-is associated with a higher likelihood of recommending nonoperative treatment than radiographs alone. Clinical information did not improve agreement of the Science of Variation Group with the actual treatment or the generally poor interobserver agreement on treatment recommendations. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Study of the anatomy of the tibial nerve and its branches in the distal medial leg.

    PubMed

    Torres, André Leal Gonçalves; Ferreira, Marcus Castro

    2012-01-01

    Determine, through dissection in fresh cadavers, the topographic anatomy of the tibial nerve and its branches at the ankle, in relation to the tarsal tunnel. Bilateral dissections were performed on 26 fresh cadavers and the locations of the tibial nerve bifurcation and its branches were measured in millimeters. For the calcaneal branches, the amount and their respective nerves of origin were also analyzed. The tibial nerve bifurcation occurred under the tunnel in 88% of the cases and proximally in 12%. As for the calcaneal branches, the medial presented with one (58%), two (34%) and three (8%) branches, with the most common source occurring in the tibial nerve (90%) and the lower with a single branch per leg and lateral plantar nerve as the most common origin (70%). Level of Evidence, V Expert opinion .

  17. A new classification and treatment protocol for combined fractures of the femoral shaft with the proximal or distal femur with closed locked intramedullary nailing: clinical experience of 63 fractures.

    PubMed

    Lambiris, Elias; Giannikas, Dimitrios; Galanopoulos, George; Tyllianakis, Minos; Megas, Panagiotis

    2003-03-01

    The medical records and radiographs of 63 patients, who were admitted between 1989-1997, with a combined femur fracture, were reviewed. Associated injuries were present in 38 (60%) patients. The combined fractures were classified into four major types depending on their anatomical position: type I, femoral shaft fracture combined with hip neck fracture; type II, femoral shaft fracture combined with a trochanteric fracture; type III, femoral shaft fracture combined with a distal femur fracture; and type IV, femoral shaft fracture combined with a proximal or distal femur fracture. The fractures were treated with locked intramedullary nailing and additional free cancellous 6.5-mm screws as needed. Fifty-six fractures healed without further operations. Of the remaining 6 fractures, 2 were material failures, 1 malunion with 3-cm shortening and external rotation of the femoral diaphysis, 2 early infections of the surgical wound, and 1 pseudarthrosis of the femoral shaft. All fractures were healed between 16 and 32 weeks (average: 20 weeks).

  18. Modified Thomas splint-cast combination for the management of limb fractures in small equids.

    PubMed

    Ladefoged, Søren; Grulke, Sigrid; Busoni, Valeria; Serteyn, Didier; Salciccia, Alexandra; Verwilghen, Denis

    2017-04-01

    To describe the management and outcome of limb fractures in small domestic equids treated with a modified Thomas splint-cast combination (MTSCC). Retrospective case series. Client owned horses and donkeys. Medical records, including radiographs, were reviewed for details of animals diagnosed with a limb fracture and treated by external coaptation using a MTSCC (2001-2012). Follow-up >6 months after discharge was obtained via telephone consultation with owners or veterinarians. Nine horses and 4 donkeys were identified with fractures of the tibial diaphysis (n = 4), ulna (n = 3), distal metatarsus (n = 2), proximal metacarpus (n = 1), radial diaphysis (n = 1), calcaneus (n = 1), and distal femoral physis (n = 1). Follow-up was available for 12 equids, of which 8 (67%) recovered from the fracture and became pasture sound. Six equids developed obvious external deformation of the affected limb. Selected small equids with long bone fractures, and without athletic expectations, can be managed with external coaptation using an MTSCC. The owner should be informed that the treatment is considered a salvage procedure. © 2017 The American College of Veterinary Surgeons.

  19. Mandibular Reconstruction with Lateral Tibial Bone Graft: An Excellent Option for Oral and Maxillofacial Surgery.

    PubMed

    Miceli, Ana Lucia Carpi; Pereira, Livia Costa; Torres, Thiago da Silva; Calasans-Maia, Mônica Diuana; Louro, Rafael Seabra

    2017-12-01

    Autogenous bone grafts are the gold standard for reconstruction of atrophic jaws, pseudoarthroses, alveolar clefts, orthognathic surgery, mandibular discontinuity, and augmentation of sinus maxillary. Bone graft can be harvested from iliac bone, calvarium, tibial bone, rib, and intraoral bone. Proximal tibia is a common donor site with few reported problems compared with other sites. The aim of this study was to evaluate the use of proximal tibia as a donor area for maxillofacial reconstructions, focusing on quantifying the volume of cancellous graft harvested by a lateral approach and to assess the complications of this technique. In a retrospective study, we collected data from 31 patients, 18 women and 13 men (mean age: 36 years, range: 19-64), who were referred to the Department of Oral and Maxillofacial Surgery at the Servidores do Estado Federal Hospital. Patients were treated for sequelae of orthognathic surgery, jaw fracture, nonunion, malunion, pathology, and augmentation of bone volume to oral implant. The technique of choice was lateral access of proximal tibia metaphysis for graft removal from Gerdy tubercle under general anesthesia. The mean volume of bone harvested was 13.0 ± 3.7 mL (ranged: 8-23 mL). Only five patients (16%) had minor complications, which included superficial infection, pain, suture dehiscence, and unwanted scar. However, none of these complications decreases the result and resolved completely. We conclude that proximal tibia metaphysis for harvesting cancellous bone graft provides sufficient volume for procedures in oral and maxillofacial surgery with minimal postoperative morbidity.

  20. Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants.

    PubMed

    Füchtmeier, B; May, R; Hente, R; Maghsudi, M; Völk, M; Hammer, J; Nerlich, M; Prantl, L

    2007-08-01

    The biomechanical stability of a newly developed humerus nail (Sirustrade mark) for the treatment of fractures of the proximal humerus was analyzed in comparison to established systems. In total, three randomized groups were formed (n = 4 pairs) from 12 matched pairs of human cadaver humeri. All intact bones were mechanically characterized by five subsequent load cycles under bending and torsional loading. The bending moment at the osteotomy was 7.5 N m the torsional moment was 8.3 N m over the hole specimen length. Loading was consistently initiated at the distal epiphysis and the deformation at the distal epiphysis was continuously recorded. Prior to implant reinforcement, a defect of 5 mm was created to simulate an unstable subcapital humerus fracture. For paired comparison, one humerus of each pair was stabilized with the Sirus proximal humerus nail while the counterpart was stabilized by a reference implant. In detail, the following groups were created: Sirus versus Proximal humerus nail (PHN) with spiral blade (group I); Sirus versus PHILOS plate (group II); Sirus versus 4.5 mm AO T-plate (group III). The Sirus nail demonstrated significantly higher stiffness values compared to the reference implants for both bending and torsional loading. The following distal epiphyseal displacements were recorded for a bending moment of 7.5 N m at the osteotomy: Sirus I: 8.8 mm, II: 8.4 mm, III: 7.7 mm (range 6.9-10.9), PHN 21.1 mm (range 15.7-25.2) (P = 0.005), PHILOS plate 27.5 mm (range 21.6-35.8) (P < 0.001), 4.5 AO T-plate 26.3 mm (range 24.3-33.9) (P = 0.01). The rotations corresponding to 8.3 N m torsional moment were: Sirus I: 9.1 degrees , II: 9.3 degrees , III: 10.6 degrees (range 7.5-12.2), PHN 13.5 degrees (range 10.3-15.6) (P = 0.158), PHILOS plate 15.6 degrees (range 13.7-20.8) (P = 0.007), 4.5 AO T-Platte 14.1 degrees (range 11.5-19.7) (P = 0.158). The intramedullary load carriers were biomechanically superior when compared to the plating systems in the

  1. Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?

    PubMed

    Königshausen, M; Kübler, L; Godry, H; Citak, M; Schildhauer, T A; Seybold, D

    2012-02-01

    The surgical treatment of displaced proximal humeral fractures (ORIF) is a perpetual challenge to the surgeon. For this reason, the principle of polyaxiality was developed to provide an improved primary stability of the fracture through better anchorage of the screws, especially in osteoporotic bone. The aim of this study was to present clinical results with the polyaxial locking plate in the operative treatment of proximal humerus fractures in order to determine whether the technique of polyaxiality leads to better functional outcome and lower complication rates in comparison to monoaxial plates in the literature. Seventy-three patients with displaced proximal humeral fractures were treated surgically with the polyaxial locking Suture Plate™ (Arthrex(®)) between 03/2007 and 06/2009. Fifty-two of the patients (mean age, 69.9 ± 12.1) were included in a radiographical and clinical examination using the Constant score (CS) and the Disabilities of the Arm, Shoulder and Hand score (DASH). The follow-up examinations were on average 13.9 ± 4.5 months (10-27 months) after surgical treatment. The mean CS of the patients was 66.0 ± 13.7 points, the age- and gender-related CS was 90.9% ± 20.0% and the mean DASH score was 23.8 ± 19.8 points for the injured side. The patients with a nearly anatomical reduction of their fracture (n = 13) reached a significantly higher CS (75.1 ± 8.5; p = 0.004) and DASH-score (13.6 ± 11.6; p = 0.043) and none of these patients had a complication. The complications were identified in 12 (23.1%) cases, 5 of which involved loss of reduction. All of these 5 cases were lacking of initial medial column support and 4 of which were type C2.3 AO-Classification. The data show that the combination of angular stability with the possibility of variable polyaxial screw direction is a good concept for reduction and fixation of displaced proximal humeral fractures, but anatomical reduction and medial support remain important preconditions for a good

  2. The Effect of Tibial Plateau Levelling Osteotomy on Stifle Extensor Mechanism Load: A Canine Ex Vivo Study.

    PubMed

    Drew, Jarrod O; Glyde, Mark R; Hosgood, Giselle L; Hayes, Alex J

    2018-02-01

     To evaluate the effect of tibial plateau levelling osteotomy on stifle extensor mechanism load in an ex vivo cruciate-intact canine cadaveric model.   Ex vivo mechanical testing study.  Cadaveric canine pelvic limbs ( n  = 6).  A 21-mm tibial radial osteotomy was performed on pelvic limbs ( n  = 6) prior to being mounted into a load-bearing limb press. The proximal tibial segment was incrementally rotated until the anatomical tibial plateau angle had been rotated to at least 1°. The proportional change in stifle extensor mechanism load between the anatomical tibial plateau angle and the neutralized (∼6.5 degrees) and over-rotated (∼1°) tibial plateau angle was analysed using a one-sample t -test against a null hypothesis of no change. A p -value ≤0.05 was considered significant.  There was no significant change in the stifle extensor mechanism load from the anatomical tibial plateau angle (308 N [261-355 N]) to the neutralized tibial plateau angle (313 N [254-372 N]; p =.81), or from the anatomical tibial plateau angle to the over-rotated tibial plateau angle (303 N [254-352 N; p  = 0.67).  Tibial plateau levelling osteotomy does not significantly alter stifle extensor mechanism load at either a neutralized or over-rotated tibial plateau angle in our cruciate-intact model. Schattauer GmbH Stuttgart.

  3. [The Extended Deltoid-Split Approach for Plating Four-Part Proximal Humeral Fractures].

    PubMed

    Schiffer, G; Sayar, A; Thelen, U

    2016-08-01

    The deltoideopectoral approach is established as the gold standard in the surgical treatment of proximal humeral fractures. As an alternative, we demonstrate the extended deltoid approach with an intraoperative video. A direct lateral incision is performed and the anterior parts of the axillary nerve are identified and preserved. In our experience, this approach allows improved visualisation of the greater tuberosity and easier positioning of locking plates. Clinically relevant neurological injuries cannot be seen in our patients or in the literature. Georg Thieme Verlag KG Stuttgart · New York.

  4. Incidence of complications associated with tibial tuberosity advancement in Boxer dogs.

    PubMed

    de Lima Dantas, Brigite; Sul, Rui; Parkin, Tim; Calvo, Ignacio

    2016-01-01

    To retrospectively review and describe the incidence of complications associated with tibial tuberosity advancement (TTA) surgical procedures in a group of Boxer dogs (n = 36 stifles) and compare the data with a non-Boxer control population (n = 271 stifles). Retrospective analysis of medical records to identify all dogs that underwent TTA surgery due to cranial cruciate ligament disease. These records were categorized into two groups: Boxer dogs and non-Boxer dogs (controls - all other breeds). Of the 307 stifles included, 69 complications were reported in 58 joints. The complication rate differed significantly for Boxer dogs (16/36 stifles) and non-Boxer dogs (42/271 stifles), corresponding to an odds ratio of 5.8 (confidence interval: 1.96-17.02; p-value <0.001). Boxer dogs were more likely to undergo revision surgery and to develop multiple complications. The incidence of tibial tuberosity fractures requiring surgical repair (2/36 versus 1/271) and incisional infections requiring antibiotic treatment (three in each group) was significantly higher in the Boxer group. Boxer dogs had more major and multiple complications after TTA surgery than the control non-Boxer group; these complications included higher rates of revision surgery, tibial tuberosity fractures requiring stabilization, and infection related complications. The pertinence and value of breed-specific recommendations for cranial cruciate ligament disease appears to be a subject worthy of further investigation.

  5. Postoperative Evaluation of Reduction Loss in Proximal Humeral Fractures: A Comparison of Plain Radiographs and Computed Tomography.

    PubMed

    Jia, Xiao-Yang; Chen, Yan-Xi; Qiang, Min-Fei; Zhang, Kun; Li, Hao-Bo; Jiang, Yu-Chen; Zhang, Yi-Jie

    2017-05-01

    To compare postoperative CT images with plain radiographs for measuring prognostic factors of reduction loss of fractures of the proximal part of the humerus. A total of 65 patients who sustained fractures of the proximal humerus treated with locking plates from June 2012 to October 2015 were retrospectively analyzed. There were 24 men and 41 women, with a mean age of 60.0 years (range, 22-76 years). According to the Neer classification system of proximal humeral fracture, there were 26 two-part, 27 three-part and 12 four-part fractures of the proximal part of the humerus, and all fractures were treated with open reduction and internal fixation (ORIF) using locked plating. All postoperative CT images and plain radiographs of the patients were obtained. Prognostic factors of the reduction loss were the change of neck shaft angle (NSA) and the change of humeral head height (HHH). The change of NSA and HHH were evaluated by the difference between postoperative initial and final follow-up measurement. Reduction loss was defined as the change ≥10° for NSA or ≥5 mm for HHH. The NSA and HHH were measured using plain radiographs and 3-D CT images, both initially and at final follow-up. The paired t-test was used for comparison of NSA, change of NSA, HHH, and change of HHH between two image modalities. The differences between two image modalities in the assessment of reduction loss were examined using the χ 2 -test (McNemar test). Intraclass correlation coefficients (ICC) were used to assess the intra-observer and inter-observer reliability. 3-D CT images (ICC range, 0.834-0.967) were more reliable in all parameters when compared with plain radiographs (ICC range, 0.598-0.915). Significant differences were found between the two image modalities in all parameters (plain radiographs: initial NSA = 133.6° ± 3.8°, final NSA = 130.0° ± 1.9°, initial HHH = 17.9 ± 0.9 mm, final HHH = 15.8 ± 1.5 mm; 3-D CT: initial NSA = 131.4° ± 3.4°, final NSA = 128.8° ± 1.7

  6. Effect of tibial slope on the stability of the anterior cruciate ligament-deficient knee.

    PubMed

    Voos, James E; Suero, Eduardo M; Citak, Musa; Petrigliano, Frank P; Bosscher, Marianne R F; Citak, Mustafa; Wickiewicz, Thomas L; Pearle, Andrew D

    2012-08-01

    We aimed to quantify the effect of changes in tibial slope on the magnitude of anterior tibial translation (ATT) in the anterior cruciate ligament (ACL)-deficient knee during the Lachman and mechanized pivot shift tests. We hypothesized that increased posterior tibial slope would increase the amount of ATT of an ACL-deficient knee, while leveling the slope of the tibial plateau would decrease the amount of ATT. Lachman and mechanized pivot shift tests were performed on hip-to-toe cadaveric specimens, and ATT of the lateral and the medial compartments was measured using navigation (n = 11). The ACL was then sectioned. Stability testing was repeated, and ATT was recorded. A proximal tibial osteotomy in the sagittal plane was then performed achieving either +5 or -5° of tibial slope variation after which stability testing was repeated (n = 10). Sectioning the ACL resulted in a significant increase in ATT in both the Lachman and mechanized pivot shift tests (P < 0.05). Increasing or decreasing the slope of the tibial plateau had no effect on ATT during the Lachman test (n.s.). During the mechanized pivot shift tests, a 5° increase in posterior slope resulted in a significant increase in ATT compared to the native knee (P < 0.05), while a 5° decrease in slope reduced ATT to a level similar to that of the intact knee. Tibial slope changes did not affect the magnitude of translation during a Lachman test. However, large changes in tibial slope variation affected the magnitude of the pivot shift.

  7. [Should one choose the nail or the plate in treating a leg fracture?].

    PubMed

    Vives, P; Massy, E; Dubois, P; Decoopmann, P

    1975-12-01

    The authors have analysed the results of 126 tibial fractures treated by blind nailing with reaming and 112 tibial fractures treated by plating. They noted 5 septic complications after nailing, after plating, one non-union after nailing and 12 after plating, 3 malunions after nailing and 2 after plating. The cases treated by nailing united earlier. The Authors conclude that nailing is a more fiable technique than plating, and that the only fractures which should be plated are those which are not fit for nailing.

  8. Epidemiology of fractures of the proximal third of the femur in elderly patients☆

    PubMed Central

    Daniachi, Daniel; Netto, Alfredo dos Santos; Ono, Nelson Keiske; Guimarães, Rodrigo Pereira; Polesello, Giancarlo Cavalli; Honda, Emerson Kiyoshi

    2015-01-01

    Objective This was an epidemiological study on fractures of the proximal third of the femur in elderly patients who were treated at a teaching hospital in the central region of São Paulo. Methods The subjects were patients over the age of 60 years who were attended over a 1-year period. A questionnaire seeking basic sociodemographic data and information on comorbidities presented and medications used was drawn up. The circumstances of the fractures and their characteristics, the treatment instituted and the intra-hospital mortality rate were evaluated. Results The 113 patients included in the study presented a mean age of 79 years. The ratio between the sexes was three women to each man. Only 30.4% of the patients reported having osteoporosis and only 0.9% had had treatment for the disease. Low-energy trauma was the cause of 92.9% of the fractures. Femoral neck fractures accounted for 42.5% of the fractures and trochanteric fractures, 57.5%. Five patients did not undergo operations; 39 underwent joint replacement; and 69 underwent osteosynthesis. The mean length of hospital stay was 13.5 days and the mean length of waiting time until surgery was 7 days. The intra-hospital mortality rate was 7.1%. Conclusion The patients attended at this institution presented an epidemiological profile similar to what is found in the Brazilian literature. Chronic kidney failure is a significant factor with regard to intra-hospital mortality. Preventive measures such as early diagnosis and treatment of osteoporosis and regular physical activity practices were not implemented. PMID:26401497

  9. [Operative treatment of proximal humeral four-part fractures in elderly patients: comparison of two angular-stable implant systems].

    PubMed

    Kuhlmann, T; Hofmann, T; Seibert, O; Gundlach, G; Schmidt-Horlohé, K; Hoffmann, R

    2012-04-01

    Although being one of the most common fractures in elderly patients, there is still no standardised treatment protocol for four-part fractures of the proximal humerus. However, a wide variety of angular-stable implants is available. The present retrospective study compares the clinical and radiological outcome following operative treatment of four-part fractures of the proximal humerus with the Philos system (Philos, proximal humeral internal locking system, Synthes GmbH, Umkirch Germany) and the angular-stable Königsee plate system (Königsee Implantate GmbH, Allendorf, Germany) in patients older than 65 years. From July 2005 until December 2007 we identified 77 patients with a four-part fracture of the proximal humerus who were treated operatively with one of the two implant systems. Of the patients, 17 could not be located so that in total 60 patients (78 %) participated in this study. The mean age of the 30 patients (10 m, 20 f) in the Philos group was 69 years (65-92), whereas the mean age of the 30 patients (11 m, 19 f) in the Königsee group was 71 years (65-93). A comprehensive assessment was performed after a median of 17 months (12-24), including physical examination, radiographic examination and completion of the disabilities of the arm, shoulder and hand score (DASH) and the Constant score (CS) as patient-oriented, limb-specific questionnaires. Neither in the Philos nor in the Königsee group could excellent results be achieved. Using the CS 13 patients (43 %) of the Philos group achieved a good and 15 (50 %) a satisfactory result. Bad results were found in 2 patients (7 %). The mean CS was 61.53 points. In the Königsee group mean CS was 61.76 points. In detail, 14 patients (47 %) treated with the Königsee implant were rated as good and 15 (50 %) as satisfactory. Only 1 patient (3 %) was rated as poor. No significant statistical differences were found between the groups. Mean DASH score in the Philos group was 56.30 points and 55.37 points in the K

  10. [Early results of proximal femoral fractures treated with FENIX modular hemiarthroplasty].

    PubMed

    Görski, Radosław; Górecki, Andrzej; Olszewski, Paweł; Biedrzycki, Jerzy; Skowronek, Paweł

    2010-01-01

    The article discusses preliminary clinical results in patients with proximal femoral fractures treated with hemiarthroplasty using a FENIX implant. The study group comprised 41 subjects aged 69 to 97 (median age 82.3 year). The follow-up study provided data on 26 subjects (63.4%), among which 15 attended the check-up, 5 subjects refused to visit at the Department and 6 subjects were reported as deceased. Median follow-up period amounted to 6.8 month (1 to 22 months). General hospitalization-related complications occurred in 8 patients (19.5%). During hospitalization no deaths occurred, in the deceased group 3 patients died within 12 months after surgery, while another 3 died after the twelve-month postoperative period (median of 13.3%). According to Merle d'Aubigne-Postel score favorable long-term results were observed in 9 patients (59.9%), 13 patients regained the level of motor function similar to the functional ability prior to fracture. The need to postpone the surgery due to general health status and impaired pre-operative motor function are significant negative prognostic factors. The results obtained were compared with previous efficacy studies on femoral fracture treatment using an Austin-Moore implant. Functional ability and self-reliance was higher in the FENIX group. FENIX arthroplasty effectively helps patients regain self-reliance and motor function thanks to its modular characteristics and anatmoical construction.

  11. Study of the anatomy of the tibial nerve and its branches in the distal medial leg

    PubMed Central

    Torres, André Leal Gonçalves; Ferreira, Marcus Castro

    2012-01-01

    Objective Determine, through dissection in fresh cadavers, the topographic anatomy of the tibial nerve and its branches at the ankle, in relation to the tarsal tunnel. Methods Bilateral dissections were performed on 26 fresh cadavers and the locations of the tibial nerve bifurcation and its branches were measured in millimeters. For the calcaneal branches, the amount and their respective nerves of origin were also analyzed. Results The tibial nerve bifurcation occurred under the tunnel in 88% of the cases and proximally in 12%. As for the calcaneal branches, the medial presented with one (58%), two (34%) and three (8%) branches, with the most common source occurring in the tibial nerve (90%) and the lower with a single branch per leg and lateral plantar nerve as the most common origin (70%). Level of Evidence, V Expert opinion. PMID:24453596

  12. Stress fracture of the proximal humeral epiphysis in an elite junior badminton player.

    PubMed Central

    Boyd, K T; Batt, M E

    1997-01-01

    An elite junior badminton player presented with a chronic painful dominant shoulder after an intense training course. An acute stress fracture to the proximal humeral epiphysis was found. Two-plane radiography will identify abnormalities of the growth plate but comparative films of the unaffected side may also be required to differentiate subtle changes. Rest with subsequent rehabilitation is the appropriate management of these injuries although ideally they should be subjected to primary prevention. Images Figure 1 Figure 2 PMID:9298564

  13. The Effect of Geographic Proximity to Unconventional Oil and Gas Development on Public Support for Hydraulic Fracturing.

    PubMed

    Boudet, Hilary S; Zanocco, Chad M; Howe, Peter D; Clarke, Christopher E

    2018-04-10

    With the rapid growth of unconventional oil and natural gas development transforming the U.S. economic and physical landscape, social scientists have increasingly explored the spatial dynamics of public support for this issue-that is, whether people closer to unconventional oil and gas development are more supportive or more opposed. While theoretical frameworks like construal-level theory and the "Not in My Backyard" (or NIMBY) moniker provide insight into these spatial dynamics, case studies in specific locations experiencing energy development reveal substantial variation in community responses. Larger-scale studies exploring the link between proximity and support have been hampered by data quality and availability. We draw on a unique data set that includes geo-coded data from national surveys (nine waves; n = 19,098) and high-resolution well location data to explore the relationship between proximity and both familiarity with and support for hydraulic fracturing. We use two different measures of proximity-respondent distance to the nearest well and the density of wells within a certain radius of the respondent's location. We find that both types of proximity to new development are linked to more familiarity with hydraulic fracturing, even after controlling for various individual and contextual factors, but only distance-based proximity is linked to more support for the practice. When significant, these relationships are similar to or exceed the effects of race, income, gender, and age. We discuss the implications of these findings for effective risk communication as well as the importance of incorporating spatial analysis into public opinion research on perceptions of energy development. © 2018 Society for Risk Analysis.

  14. Prediction of fracture load and stiffness of the proximal femur by CT-based specimen specific finite element analysis: cadaveric validation study.

    PubMed

    Miura, Michiaki; Nakamura, Junichi; Matsuura, Yusuke; Wako, Yasushi; Suzuki, Takane; Hagiwara, Shigeo; Orita, Sumihisa; Inage, Kazuhide; Kawarai, Yuya; Sugano, Masahiko; Nawata, Kento; Ohtori, Seiji

    2017-12-16

    Finite element analysis (FEA) of the proximal femur has been previously validated with large mesh size, but these were insufficient to simulate the model with small implants in recent studies. This study aimed to validate the proximal femoral computed tomography (CT)-based specimen-specific FEA model with smaller mesh size using fresh frozen cadavers. Twenty proximal femora from 10 cadavers (mean age, 87.1 years) were examined. CT was performed on all specimens with a calibration phantom. Nonlinear FEA prediction with stance configuration was performed using Mechanical Finder (mesh,1.5 mm tetrahedral elements; shell thickness, 0.2 mm; Poisson's coefficient, 0.3), in comparison with mechanical testing. Force was applied at a fixed vertical displacement rate, and the magnitude of the applied load and displacement were continuously recorded. The fracture load and stiffness were calculated from force-displacement curve, and the correlation between mechanical testing and FEA prediction was examined. A pilot study with one femur revealed that the equations proposed by Keller for vertebra were the most reproducible for calculating Young's modulus and the yield stress of elements of the proximal femur. There was a good linear correlation between fracture loads of mechanical testing and FEA prediction (R 2 = 0.6187) and between the stiffness of mechanical testing and FEA prediction (R 2 = 0.5499). There was a good linear correlation between fracture load and stiffness (R 2 = 0.6345) in mechanical testing and an excellent correlation between these (R 2 = 0.9240) in FEA prediction. CT-based specimen-specific FEA model of the proximal femur with small element size was validated using fresh frozen cadavers. The equations proposed by Keller for vertebra were found to be the most reproducible for the proximal femur in elderly people.

  15. Augmentation of tibial plateau fractures with an injectable bone substitute: CERAMENT™. Three year follow-up from a prospective study.

    PubMed

    Iundusi, Riccardo; Gasbarra, Elena; D'Arienzo, Michele; Piccioli, Andrea; Tarantino, Umberto

    2015-05-13

    Reduction of tibial plateau fractures and maintain a level of well aligned congruent joint is key to a satisfactory clinical outcome and is important for the return to pre-trauma level of activity. Stable internal fixation support early mobility and weight bearing. The augmentation with bone graft substitute is often required to support the fixation to mantain reduction. For these reasons there has been development of novel bone graft substitutes for trauma applications and in particular synthetic materials based on calcium phosphates and/or apatite combined with calcium sulfates. Injectable bone substitutes can optimize the filling of irregular bone defects. The purpose of this study was to assess the potential of a novel injectable bone substitute CERAMENT™|BONE VOID FILLER in supporting the initial reduction and preserving alignment of the joint surface until fracture healing. From June 2010 through May 2011 adult patients presenting with acute, closed and unstable tibial plateau fractures which required both grafting and internal fixation, were included in a prospective study with percutaneous or open reduction and internal fixation (ORIF) augmented with an injectable ceramic biphasic bone substitute CERAMENT™|BONE VOID FILLER (BONESUPPORT™, Lund, Sweden) to fill residual voids. Clinical follow up was performed at 1, 3, 9 and 12 months and any subsequent year; including radiographic analysis and Rasmussen system for knee functional grading. Twenty four patients, balanced male-to-female, with a mean age of 47 years, were included and followed with an average of 44 months (range 41-52 months). Both Schatzker and Müller classifications were used and was type II or 41-B3 in 7 patients, type III or 41-B2 in 12 patients, type IV or 41-C1 in 2 patients and type VI or 41-C3 in 3 patients, respectively. The joint alignement was satisfactory and manteined within a range of 2 mm, with an average of 1.18 mm. The mean Rasmussen knee function score was 26.5, with 14

  16. Rate of avascular necrosis and time to surgery in proximal humerus fractures.

    PubMed

    Archer, L A; Furey, A

    2016-12-01

    Avascular necrosis (AVN) of the humeral head is a devastating complication of proximal humeral fracture (PHF) that often results in long-term morbidity for the patient. Rates of AVN depend on the number of fracture fragments and are highly variable. The literature suggests that timely stable and anatomic reduction may decrease the rate at which AVN develops after PHF. To our knowledge, there is no literature published investigating a temporal relationship between the timing of PHF fixation and rates of AVN. Operative records of one orthopedic trauma surgeon were used to identify patients that underwent open reduction internal fixation for PHF at our institution between 2007 and 2012. Radiographs at presentation were reviewed and used to classify the fractures into two, three or four parts. Date and time of the initial radiograph were recorded as were the date and time of available intra-operative fluoroscopic images. The time from presentation radiograph to operative fixation was calculated (hours). Available follow-up plain films were then reviewed and evaluated for the presence or absence of humeral head AVN. Time to surgery (less than or greater than 72 h) and patient age did not correlate with development of AVN after PHF (p > 0.26). Notably, the number of fracture fragments did influence the rate of AVN identified in patients with PHF (p = 0.002). Early operative intervention does not appear to decrease the rate of development of avascular necrosis after PHF.

  17. Three-part head-splitting proximal humerus fracture through a unicameral bone cyst.

    PubMed

    Younghein, John A; Eskander, Mark S; DeAngelis, Nicola A; Wixted, John J

    2012-06-01

    Unicameral bone cysts are rare in adults and are most often found incidentally on radiographs. However, they can persist from the adolescent period and may be present in locations that predispose to or exacerbate fractures.This article describes a case of a healthy 40-year-old woman who sustained a proximal humerus trauma that involved a large unicameral bone cyst, resulting in a 3-part head-splitting fracture. The epiphyseal location of the cyst contributed to the severity and extent of the fracture that resulted from a simple fall. Given the age of the patient, open reduction and internal fixation with a locking plate and lag screws was performed. The patient chose open reduction and internal fixation to preserve a hemiarthroplasty procedure in case of future revision. Successful humeral head reconstruction was achieved, and the patient fully recovered. One year postoperatively, the patient underwent arthroscopic debridement to alleviate subjective stiffness and decreased range of motion.Multipart head-splitting fractures require complex repair strategies. The gold standard for the treatment of these injuries is hemiarthroplasty. However, the decision process is difficult in a young patient given the average survival of autoplastic prostheses and the added difficulty of later revision. The current case demonstrates the complexity of decision making resulting from a rare injury in a young, healthy patient and shows that open reduction and internal fixation can provide acceptable reconstruction in such situations. Copyright 2012, SLACK Incorporated.

  18. Pediatric distal femur fixation by proximal humeral plate.

    PubMed

    Abdelgawad, Amr Atef; Kanlic, Enes M

    2013-12-01

    Distal femoral metaphyseal fractures are common injuries in children. Multiple treatment options have been described for this type of injury. For older children with distal metaphyseal fracture, there is still no optimal method of fixation. We propose that the commonly used proximal humeral plate can provide good method of fixation for this fracture in adolescents. Two children (12 and 14 years old) with distal metaphyseal femoral fracture were treated with proximal humeral plate. We describe the surgical technique and postoperative management. The two children healed with good alignment and full range of motion of the knee. No external immobilization (other than knee immobilizer for the first 2 weeks) was used. We concluded that proximal humeral plate can provide adequate fixation for teenagers with distal femoral metaphyseal fracture. It is readily available; provide multiple options for screw fixation in the distal part of the fracture and fits easily on the distal part of the femur proximal to the physis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Intra-articular fractures of the distal tibia

    PubMed Central

    Sitnik, Alexandre; Beletsky, Aleksander; Schelkun, Steven

    2017-01-01

    Results of the treatment of intra-articular fractures of the distal tibia have improved significantly during the last two decades. Recognition of the role of soft tissues has led to the development of a staged treatment strategy. At the first stage, joint-bridging external fixation and fibular fixation are performed. This leads to partial reduction of the distal tibial fracture and allows time for the healing of soft tissues and detailed surgical planning. Definitive open reduction and internal fixation of the tibial fracture is performed at a second stage, when the condition of the soft tissues is safe. The preferred surgical approach(es) is chosen based on the fracture morphology as determined from standard radiographic views and computed tomography. Meticulous atraumatic soft-tissue handling and the use of modern fixation techniques for the metaphyseal component such as minimally invasive plate osteosynthesis further facilitate healing. Cite this article: EFORT Open Rev 2017;2:352-361. DOI: 10.1302/2058-5241.2.150047 PMID:28932487

  20. High altitude hypoxia as a factor that promotes tibial growth plate development in broiler chickens

    PubMed Central

    Huang, Shucheng; Zhang, Lihong; Rehman, Mujeeb Ur; Iqbal, Muhammad Kashif; Lan, Yanfang; Mehmood, Khalid; Zhang, Hui; Qiu, Gang; Nabi, Fazul; Yao, Wangyuan; Wang, Meng; Li, Jiakui

    2017-01-01

    Tibial dyschondroplasia (TD) is one of the most common problems in the poultry industry and leads to lameness by affecting the proximal growth plate of the tibia. However, due to the unique environmental and geographical conditions of Tibet, no case of TD has been reported in Tibetan chickens (TBCs). The present study was designed to investigate the effect of high altitude hypoxia on blood parameters and tibial growth plate development in chickens using the complete blood count, morphology, and histological examination. The results of this study showed an undesirable impact on the overall performance, body weight, and mortality of Arbor Acres chickens (AACs) exposed to a high altitude hypoxic environment. However, AACs raised under hypoxic conditions showed an elevated number of red blood cells (RBCs) and an increase in hemoglobin and hematocrit values on day 14 compared to the hypobaric normoxia group. Notably, the morphology and histology analyses showed that the size of tibial growth plates in AACs was enlarged and that the blood vessel density was also higher after exposure to the hypoxic environment for 14 days, while no such change was observed in TBCs. Altogether, our results revealed that the hypoxic environment has a potentially new role in increasing the blood vessel density of proximal tibial growth plates to strengthen and enhance the size of the growth plates, which may provide new insights for the therapeutic manipulation of hypoxia in poultry TD. PMID:28282429