Sample records for radiology die implantation

  1. Histological, mechanical, and radiological study of osteoformation in titanium foam implants.

    PubMed

    Ito, Kiyoshi; Horiuchi, Tetsuyoshi; Arai, Yoshinori; Kawahara, Ichiro; Hongo, Kazuhiro

    2014-11-01

    Titanium (Ti) is widely used for implants because of its high mechanical reliability and because it aids osteoformation. However, it also produces artifacts during radiological imaging. Further, Ti implants can sometimes cause the surrounding bone to break. Owing to recent advances, Ti can be transformed into sponge-like, porous materials having a three-dimensional network of pores; such materials are called Ti foams. These foams exhibit distinct characteristics that make them more suitable than nonporous Ti. The objective of this study was to evaluate Ti foams as implant materials. Implants based on Ti foams having porosities of 80% and 90% were embedded in the femurs of 11 rabbits. Implants based on 0% porosity Ti were used as controls. Five rabbits were sacrificed 4 weeks after implantation, while the remaining were sacrificed after 12 weeks. The femurs containing the Ti implants were harvested and analyzed. Biomechanical analyses showed that the 80% porosity implants induced greater osteoformation. There were significant differences in the average pushout strengths of the control and 80% porosity implants after 4 weeks (p = 0.048) and 12 weeks (p = 0.001). Histopathological analyses confirmed osteoformation in the case of the 80% porosity implants. Analyses of the micro-computed tomography images of the Ti foam-based implants did not suggest the presence of artifacts. The 80% porosity Ti implants did not exhibit the shortcomings associated with conventional Ti implants. In addition, they induced greater osteoformation. Finally, the Ti foams did not produce radiological artifacts.

  2. [Periinterventional prophylactic antibiotics in radiological port catheter implantation].

    PubMed

    Gebauer, B; Teichgräber, U; Werk, M; Wagner, H-J

    2007-08-01

    To evaluate whether catheter-related infections after radiologically placed port catheters can be reduced by single-shot periinterventional antibiosis. Between January and September 2002, 164 consecutive patients with indication for central venous port catheter implantation were included in the present study. During implantation the interventional radiologist was responsible for deciding whether to administer a prophylactic single-shot antibiosis. The prophylactic antibiosis entailed intravenous administration of ampicillin and sulbactam (3 g Unacid, Pfizer) or 100 mg ciprofloxacine (Ciprobay, Bayer) in the case of an allergy history to penicillins. Catheter-related infection was defined as a local or systemic infection necessitating port catheter extraction. Indication for port catheter implantation was a malignant disease requiring chemotherapy in 158 cases. The port catheter (Chemosite [Tyco Healthcare] [n = 123], low-profile [Arrow International] [n = 35], other port system [n = 6]) was implanted via sonographically guided puncture of the right jugular vein in 139 patients, via the left jugular vein in 24 cases and via the right subclavian vein in one patient. 75 patients received periinterventional prophylactic antibiosis (Unacid [n = 63] Ciprobay [n = 12]) and 89 patients did not receive antibiosis. The prophylactic antibiosis caused a minor allergic reaction in one patient that improved with antihistamic and corticoid medication. A total of 7 ports, 6 without prophylactic antibiosis versus one with periinterventional prophylaxis, were extracted due to infectious complications. Single-shot periinterventional prophylactic antibiosis can reduce early and late infectious complications after radiological-interventional placement of central venous port catheters.

  3. A retrospective study on clinical and radiological outcomes of oral implants in patients followed up for a minimum of 20 years.

    PubMed

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2018-04-01

    Very long-term follow-up of oral implants is seldom reported in the literature. To assess oral implant failure rates and marginal bone loss (MBL) of patients followed up for a minimum of 20 years. Implants placed in patients followed up for 20+ years were included. Descriptive statistics, survival analyses, generalized estimating equations were performed. Three-hundred implants were randomly selected for MBL. 1,045 implants (227 patients) were included. Implant location, irradiation, and bruxism affected the implant survival rate. Thirty-five percent of the failures occurred within the first year after implantation, and another 26.8% in the second/third year. There was a cumulative survival rate of 87.8% after 36 years of follow-up. In the last radiological follow up, 35 implants (11.7%) had bone gain, and 35 implants (11.7%) presented at least 3 mm of MBL. Twenty-six out of 86 failed implants with available radiograms presented severe MBL in the last radiological register before implant failure. Most of the implant failures occurred at the first few years after implantation, regardless of a very long follow up. MBL can be insignificant in long-term observations, but it may, nevertheless, be the cause of secondary failure of oral implants in some cases. © 2017 Wiley Periodicals, Inc.

  4. [Radiological trap and oncological precautions in a patient who has undergone a permanent withdrawal of PIP breast implants].

    PubMed

    Koutsomanis, A; Bruant-Rodier, C; Roedlich, M-N; Bretz-Grenier, M-F; Perrot, P; Bodin, F

    2015-12-01

    We report the case of a 57-year-old patient who presented radiological images similar to ruptured breast implants one year after the supposed withdrawal of the latter. This woman had benefited for the first time from cosmetic PIP breast implants in 2000. Early in 2014, she requested the removal of the implants without renewal because she was feeling pain and functional discomfort. A few months after the operation, she consulted for breast swelling in the upper pole of the breast. Radiological assessment showed liquid formations compatible with the presence of implants. At our request, the rereading of the MRI by the radiologist definitively concluded on a bilateral seroma within the persistent fibrous capsule. In the absence of symptoms, clinical monitoring had been decided. But at the recrudescence of anaplastic large cell lymphoma cases associated with breast implants, a cytological sampling was intended. In case of cytological abnormality or recurrence of the seroma, a surgical procedure should be performed. In conclusion, the removal of a breast implant without capsulectomy may result in the formation of a seroma whose images resemble those of an implant. It is always worthwhile to provide precise clinical data to the radiologist in order to help him to make informed interpretations. Every serous effusion in a breast lodge having contained a silicone implant must evoke the diagnosis of anaplastic large cell lymphoma. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. Systematic review: Radiological and histological evidence of cochlear implant insertion trauma in adult patients.

    PubMed

    Hoskison, Emma; Mitchell, Scott; Coulson, Chris

    2017-07-01

    Cochlear implantation (CI) has developed from its origins in the 1980s. Initially, CI was for profound bilateral hearing impairment. However, candidacy for CI have become more widespread in recent years with unilateral implantation and an emphasis on hearing preservation. Evidence supports full electrode insertion in an atraumatic fashion into the scala tympani (ST) provides optimal hearing outcomes. The main aim of this systematic review was to elucidate the degree of trauma associated with CI insertion. A systematic literature search was undertaken using PubMed Medline. A grading system described by Eshraghi was used to classify cochlear trauma. Both radiological and histological studies were included. Twenty one papers were identified which were relevant to our search. In total, 653 implants were inserted and 115 (17.6%) showed evidence of trauma. The cochleas with trauma had basilar membrane elevation in 5.2%, ruptured in 5.2%, the electrode passed from the ST to the SV in 84.4% and there was grade 4 trauma in 5.2%. The studies used a variety of histological and radiological methods to assess for evidence of trauma in both cadaveric temporal bones and live recipients. Minimizing cochlear trauma during implant insertion is important to preserve residual hearing and optimize audiological performance. An overall 17.6% trauma rate suggests that CI insertion could be improved with more accurate and consistent electrode insertion such as in the form of robotic guidance. The correlation of cochlea trauma with post-operative hearing has yet to be determined.

  6. Clinical and Radiologic Outcomes of Submerged and Nonsubmerged Bone-Level Implants with Internal Hexagonal Connections in Immediate Implantation: A 5-Year Retrospective Study.

    PubMed

    Wu, Shiyu; Wu, Xiayi; Shrestha, Rachana; Lin, Jinying; Feng, Zhicai; Liu, Yudong; Shi, Yunlin; Huang, Baoxin; Li, Zhipeng; Liu, Quan; Zhang, Xiaocong; Hu, Mingxuan; Chen, Zhuofan

    2018-02-01

    To evaluate the 5-year clinical and radiologic outcome of immediate implantation using submerged and nonsubmerged techniques with bone-level implants and internal hexagonal connections and the effects of potential influencing factors. A total of 114 bone-level implants (XiVE S plus) with internal hexagonal connections inserted into 72 patients were included. Patients were followed up for 5 years. A t-test was used to statistically evaluate the marginal bone loss between the submerged and nonsubmerged groups. The cumulative survival rate (CSR) was calculated according to the life table method and illustrated with Kaplan-Meier survival curves. Comparisons of the CSR between healing protocols, guided bone regeneration, implants with different sites, lengths, and diameters were performed using log-rank tests. The 5-year cumulative implant survival rates with submerged and nonsubmerged healing were 94% and 96%, respectively. No statistically significant differences in terms of marginal bone loss, healing protocol, application of guided bone regeneration, implant site, or length were observed. High CSRs and good marginal bone levels were achieved 5 years after immediate implantation of bone-level implants with internal hexagonal connections using both the submerged and nonsubmerged techniques. Factors such as implant length, site, and application of guided bone regeneration did not have an impact on the long-term success of the implants. © 2017 by the American College of Prosthodontists.

  7. [Application of a stand-alone interbody fusion cage based on a novel porous TiO2/glass composite. I. Implantation in the sheep cervical spine and radiological evaluation].

    PubMed

    Korinth, M C; Hero, T; Mahnken, A H; Ragoss, C; Scherer, K

    2004-12-01

    Animals are becoming more and more common as in vitro and in vivo models for the human spine. Especially the sheep cervical spine is stated to be of good comparability and usefulness in the evaluation of in vivo radiological, biomechanical and histological behaviour of new bone replacement materials, implants and cages for cervical spine interbody fusion. In preceding biomechanical in vitro examination human cervical spine specimens were tested after fusion with either a cubical stand-alone interbody fusion cage manufactured from a new porous TiO/glass composite (Ecopore) or polymethyl-methacrylate (PMMA) after discectomy. First experience with the use of the new material and its influence on the primary stability after in vitro application were gained. After fusion of 10 sheep cervical spines in the levels C2/3 and C4/5 in each case with PMMA and with an Ecopore-cage, radiologic as well as computertomographic examinations were performed postoperatively and every 4 weeks during the following 2 and 4 months, respectively. Apart from establishing our animal model, we analysed the radiological changes and the degree of bony fusion of the operated segments during the course. In addition we performed measurements of the corresponding disc space heights (DSH) and intervertebral angles (IVA) for comparison among each other, during the course and with the initial values. Immediately after placement of both implants in the disc spaces the mean DSH and IVA increased (34.8% and 53.9%, respectively). During the following months DSH decreased to a greater extent in the Ecopore-segments than in the PMMA-segments, even to a value below the initial value (p>0.05). Similarly, the IVA decreased in both groups in the postoperative time lapse, but more distinct in the Ecopore-segments (p<0.05). These changes in terms of a subsidence of the implants, were confirmed morphologically in the radiological examination in the course. The radiologically evaluated fusion, i.e. bony bridging of

  8. Clinical and Radiological Long-Term Outcome of a Tapered Implant System with Special Emphasis on the Influence of Augmentation Procedures.

    PubMed

    Schiegnitz, Eik; Al-Nawas, Bilal; Tegner, Alexander; Sagheb, Keyvan; Berres, Manfred; Kämmerer, Peer W; Wagner, Wilfried

    2016-08-01

    Tapered implant designs aim to improve primary stability and implant survival in soft bone. However, respective clinical long-term data are scarce. Therefore, a clinical and radiological evaluation of the long-term success of a transgingival-supracrestal inserted tapered implant system with special emphasis on the influence of augmentation procedures was conducted. In a retrospective study design, all in the Department of Oral and Maxillofacial Surgery of the University Medical Centre, Mainz, Germany, between May 2002 and March 2012, placed tapered implants (Straumann TE®, Basel, Switzerland) were analyzed. In this time period, a total of one hundred ninety-seven tapered implants were inserted in 90 patients. For patients available for clinical recall, success criteria according to Albrektsson and Buser were evaluated. The in situ rate was 96.3% after an average time in situ of 62 ± 31 months. In one hundred twenty-seven sites, bone augmentation procedures were performed. Hereof, 96 sites were sinus augmentation procedures and 31 sites were alveolar ridge augmentations. For patients with sinus augmentation procedures, implant survival was 97.9% and for patients with alveolar ridge augmentations, implant survival was 93.5% after 5 years, indicating a higher implant survival for sinus augmentation, however not statistically different (p = .194). Implant diameter and timing of implant placement had no significant impact on implant survival (p > .05). Mean marginal bone loss was -0.50 ± 1.54 mm for patients receiving maxillary sinus augmentation and -1.16 ± 1.13 mm for patients with alveolar ridge augmentations, indicating a lower marginal bone loss in patients receiving maxillary sinus augmentation (p = .046). Implant success rates ranged between 88% and 92% after a mean follow-up of 6 years. Within the limits of the retrospective character of this study, the tapered soft tissue level implant showed especially in maxillary sinus

  9. Assessment of a press-fit proximal femoral modular reconstruction implant (PFMR®) at 14.5 years. A 48-case series with a disturbing rate of implant fracture.

    PubMed

    Dumoulin, Q; Sabau, S; Goetzmann, T; Jacquot, A; Sirveaux, F; Mole, D; Roche, O

    2018-05-01

    The PFMR ® proximal femoral modular reconstruction implant (Protek, Sulzer Orthopedics, Switzerland) is a straight modular stem in sanded titanium with press-fit anchorage, intended to achieve spontaneous bone reconstruction following Wagner's principle. The aim of the present study was to analyze long-term clinical and radiological outcome. A single-center retrospective study included 48 PFMR stems implanted in 47 patients between 1998 and 2002. Results in this series were previously reported at 7 years' follow-up. Clinical assessment used PMA and Harris scores. Radiologic assessment focused on stem stability and osseointegration, and bone stock following Le Béguec. Twenty-three patients were seen at a mean 14.5 years' follow-up (13 deceased, 11 lost to follow-up), including 1 with bilateral implants, i.e., 24 stems. PMA and Harris scores, stem stability and osseointegration and bone stock were stable with respect to the 7-year findings. Radiology found 7 stem fractures in the Morse taper, i.e., in 29% of implants. Two of these cases required femoral implant replacement; 5 were asymptomatic. Long-term outcome for PFMR stems was clinically and radiologically satisfactory for the 16 patients free of mechanical complications. The Morse taper fracture rate was high, and higher than reported elsewhere. The usual risk factors for implant fracture were not found in the present series. The modular design of the press-fit revision implant is its weak point; monoblock implants should be used in patients with good life-expectancy. IV (retrospective study). Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  10. Implantate in der Augenheilkunde

    NASA Astrophysics Data System (ADS)

    Dresp, Joachim H.

    Im Bereich der Augenheilkunde findet sich die weltweit am häufigsten ausgeführte chirurgische Massnahme, die operative Behandlung des Grauen Stars: die Katarakt. Bei der Katarakt handelt es sich um eine Eintrübung der natürlichen Augenlinse, die sich je nach Stadium der Erkrankung leicht opak, über milchig bis zu bräunlich präsentiert. Mit dieser Zunahme der Undurchlässigkeit für das sichtbare Licht geht eine Abnahme des Sehvermögens einher, die bis zur totalen Erblindung führen kann. Bedingt durch die sehr eingeschränkten chirurgischen Möglichkeiten in den Ländern der Dritten Welt ist die Katarakt die Erblindungsursache Nummer 1 in der Welt. Ganz im Gegensatz hierzu ist in den industrialisierten Ländern Europas, Amerikas und Asiens die Katarakt-OP die sicherste chirurgische Intervention. In der Augenheilkunde werden Implantate aller drei Aggregatszustände verwendet.

  11. In vivo osseointegration of dental implants with an antimicrobial peptide coating.

    PubMed

    Chen, X; Zhou, X C; Liu, S; Wu, R F; Aparicio, C; Wu, J Y

    2017-05-01

    This study aimed to evaluate the in vivo osseointegration of implants with hydrophobic antimicrobial GL13K-peptide coating in rabbit femoral condyles by micro-CT and histological analysis. Six male Japanese Rabbits (4 months old and weighing 2.5 kg each) were included in this study. Twelve implants (3.75 mm wide, 7 mm long) were randomly distributed in two groups, with six implants in the experimental group coated with GL13K peptide and six implants in the control group without surface coating. Each implant in the test and the control group was randomly implanted in the left or right side of femoral condyles. On one side randomly-selected of the femur, each rabbit received a drill that was left without implant as control for the natural healing of bone. After 3 weeks of healing radiographic evaluation of the implant sites was taken. After 6 weeks of healing, rabbits were sacrificed for evaluation of the short-term osseointegration of the dental implants using digital radiography, micro-CT and histology analysis. To perform evaluation of osseointegration, implant location and group was double blinded for surgeon and histology/radiology researcher. Two rabbits died of wound infection in sites with non-coated implants 2 weeks after surgery. Thus, at least four rabbits per group survived after 6 weeks of healing. The wounds healed without suppuration and inflammation. No implant was loose after 6 weeks of healing. Radiography observations showed good osseointegration after 3 and 6 weeks postoperatively, which proved that the tissues followed a natural healing process. Micro-CT reconstruction and analysis showed that there was no statistically significant difference (P > 0.05) in volume of bone around the implant between implants coated with GL13K peptide and implants without coating. Histomorphometric analysis also showed that the mineralized bone area was no statistically different (P > 0.05) between implants coated with GL13K peptide and

  12. Medizintechnik in der Tumororthopädie

    NASA Astrophysics Data System (ADS)

    Burgkart, Rainer; Gollwitzer, Hans; Holzapfel, Boris; Rudert, Maximilian; Rechl, Hans; Gradinger, Reiner

    Die Behandlung der Knochentumoren unterlag in den letzten 20 Jahren einem raschen und stetigen Wandel, was zum einen auf die verbesserten Therapieerfolge durch den Einsatz von neoadjuvanten Therapieformen zurückzuführen ist, und andererseits von medizintechnischen Entwicklungen bezüglich moderner Schnittbilddiagnostik, neuer 3D Operationsplanungsverfahren wie das Rapid Prototyping und adaptiv modularer Tumorendoprothesensystemen u. a. begleitet wurde. Gerade die technischen Entwicklungen haben dazu geführt, daß im Bereich der Extremitäten und der Wirbelsäule radikalere Eingriffe durchgeführt werden können, was die lokale Tumorkontrolle wesentlich verbessert hat. In zunehmenden Maße werden deshalb nicht nur Kurzzeiterfolge sondern auch mittel- und langfristige Fortschritte bei der Behandlung der malignen Knochentumoren einschließlich der Metastasenbehandlung erreicht. Grundlage der Therapie ist dabei immer primär die Sicherung der Diagnose mittels Biopsie und die bildgebende sowie histologische Stadieneinteilung des malignen Tumors. Nach der Tumorresektion kann die Rekonstruktion biologisch oder mit Endoprothesensystemen erfolgen. Gerade die weiterentwickelten modularen Systeme führen zu guten funktionellen Ergebnissen mit langen Standzeiten und einer reduzierten Komplikationsrate. Individuell angefertigte Implantate sind vor allem im Bereich der Rekonstruktion komplexer Beckentumoren von großer klinischer Bedeutung.

  13. Multiscale Analyses of the Bone-implant Interface

    PubMed Central

    Cha, J.Y.; Pereira, M.D.; Smith, A.A.; Houschyar, K.S.; Yin, X.; Mouraret, S.; Brunski, J.B.

    2015-01-01

    Implants placed with high insertion torque (IT) typically exhibit primary stability, which enables early loading. Whether high IT has a negative impact on peri-implant bone health, however, remains to be determined. The purpose of this study was to ascertain how peri-implant bone responds to strains and stresses created when implants are placed with low and high IT. Titanium micro-implants were inserted into murine femurs with low and high IT using torque values that were scaled to approximate those used to place clinically sized implants. Torque created in peri-implant tissues a distribution and magnitude of strains, which were calculated through finite element modeling. Stiffness tests quantified primary and secondary implant stability. At multiple time points, molecular, cellular, and histomorphometric analyses were performed to quantitatively determine the effect of high and low strains on apoptosis, mineralization, resorption, and collagen matrix deposition in peri-implant bone. Preparation of an osteotomy results in a narrow zone of dead and dying osteocytes in peri-implant bone that is not significantly enlarged in response to implants placed with low IT. Placing implants with high IT more than doubles this zone of dead and dying osteocytes. As a result, peri-implant bone develops micro-fractures, bone resorption is increased, and bone formation is decreased. Using high IT to place an implant creates high interfacial stress and strain that are associated with damage to peri-implant bone and therefore should be avoided to best preserve the viability of this tissue. PMID:25628271

  14. Broken Esophageal Stent Successfully Treated by Interventional Radiology Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zelenak, Kamil, E-mail: zelenak@mfn.s; Mistuna, Dusan; Lucan, Jaroslav

    2010-06-15

    Esophageal stent fractures occur quite rarely. A 61-year-old male patient was previously treated for rupture of benign stenosis, occurring after dilatation, by implanting an esophageal stent. However, a year after implantation, the patient suffered from dysphagia caused by the broken esophageal stent. He was treated with the interventional radiology technique, whereby a second implantation of the esophageal stent was carried out quite successfully.

  15. Radiological Control Center (RADCC) Renaming Ceremony

    NASA Image and Video Library

    2017-03-31

    Space Center, presents Myrna Scott, widow of Randy Scott, with a replica of the emblem noting that the spaceport's Radiological Control Center has been named in honor of her husband who died last year. The ceremony in the center's Radiological Control Center honored the extensive contributions of Randy Scott. A professional health physicist of more than 40 years, Scott served as the Florida spaceport's Radiation Protection Officer for 14 years until his death June 17, 2016.

  16. Metal levels in corrosion of spinal implants

    PubMed Central

    Beguiristain, Jose; Duart, Julio

    2007-01-01

    Corrosion affects spinal instrumentations and may cause local and systemic complications. Diagnosis of corrosion is difficult, and nowadays it is performed almost exclusively by the examination of retrieved instrumentations. We conducted this study to determine whether it is possible to detect corrosion by measuring metal levels on patients with posterior instrumented spinal fusion. Eleven asymptomatic patients, with radiological signs of corrosion of their stainless steel spinal instrumentations, were studied by performing determinations of nickel and chromium in serum and urine. Those levels were compared with the levels of 22 patients with the same kind of instrumentation but without evidence of corrosion and to a control group of 22 volunteers without any metallic implants. Statistical analysis of our results revealed that the patients with spinal implants without radiological signs of corrosion have increased levels of chromium in serum and urine (P < 0.001) compared to volunteers without implants. Corrosion significantly raised metal levels, including nickel and chromium in serum and urine when compared to patients with no radiological signs of corrosion and to volunteers without metallic implants (P < 0.001). Metal levels measured in serum have high sensibility and specificity (area under the ROC curve of 0.981). By combining the levels of nickel and chromium in serum we were able to identify all the cases of corrosion in our series of patients. The results of our study confirm that metal levels in serum and urine are useful in the diagnosis of corrosion of spinal implants and may be helpful in defining the role of corrosion in recently described clinical entities such as late operative site pain or late infection of spinal implants. PMID:17256156

  17. Retreatment of recurrent carcinoma of the head and neck by afterloading interstitial 192Ir implant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emami, B.; Marks, J.E.

    From January 1975 to December 1980, 25 patients with persistent or recurrent carcinomas of the head and neck were retreated for palliation at the Division of Radiation Oncology, Mallinckrodt Institute of Radiology. These patients had all undergone extensive previous treatment by surgery and/or radiation. All were retreated with 192Ir interstitial implant with or without external radiation and/or surgical excision. Of 25 patients, 13 had complete response (CR) and 6 had partial response for a follow-up period of 1 to 7 years. Of 13 patients with CR, 6 are alive with no evidence of disease (NED) and two died NED. Detailedmore » results are presented and the new strategy for such patients is discussed.« less

  18. Morphologic changes of the nasopalatine canal related to dental implantation: a radiologic study in different degrees of absorbed maxillae.

    PubMed

    Mardinger, Ofer; Namani-Sadan, Noa; Chaushu, Gavriel; Schwartz-Arad, Devorah

    2008-09-01

    Implant rehabilitation of the edentulous anterior maxilla remains a complex restorative challenge. Intricate preexisting anatomy dictates meticulous and accurate osteotomy planning. With progressive bone loss, the alveolar crest may approach anatomic structures. The nasopalatine nerve and vessels may ultimately emerge from the ridge crest. The radiologic changes of the nasopalatine canal were evaluated in different resorption phases of the premaxilla alveolus with regard to dental implantation. The study consisted of 207 subjects who had maxillary computed tomography scans before dental implantation. The Lekholm and Zarb classification was used to divide images according to the residual bony ridge: Class A (control group) and classes B to E (study group). Anatomic mapping of the nasopalatine canal structure was carried out in both groups. The canal diameter was wider along the degree of ridge resorption from classes A to E in all dimensions, mainly in the palatal opening (P <0.01), middle area (P <0.001), and nasal area. The mean diameter of the enlargement was 1.8 mm, which reached 5.5 +/- 1.08 mm (P <0.01) in type E bone. In the severely resorbed ridges (classes C through E), when the palatal opening was situated on the ridge, it occupied a mean of 35.6% (13% to 58%) of the area devoted to implant placement. Tooth loss was the main reason for ridge resorption (P <0.01). Canal diameter enlargement was greater anteriorly to the ridge and posteriorly to the palatal bone, mainly because of tooth extraction. The atrophy of disuse may influence surrounding structures, similar to the maxillary sinus tendency to expand into surrounding bone mainly after tooth loss.

  19. The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up: Short title: Ossis custom 3D-Printed tri-flanged acetabular implant.

    PubMed

    Kieser, David C; Ailabouni, Ramez; Kieser, Sandra C J; Wyatt, Michael C; Armour, Paul C; Coates, Mark H; Hooper, Gary J

    2018-05-01

    Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, 1 required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tumoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n=11], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.

  20. [Radiological analysis of the thrust plate prosthesis (TPP)].

    PubMed

    Ishaque, B A; Wienbeck, S; Basad, E; Stürz, H

    2004-01-01

    The various radiological changes after implantation of the thrust plate prosthesis (TPP) are demonstrated and, with the help of a standardized radiological classification, divided in pathological and non-pathological findings. The radiological follow-ups of 167 TPP implanted between 1993 and 1998 was analyzed in this study. The follow-up examination was carried out postoperatively, after 6 months and subsequently every year. The radiological assessment was carried out in an exact a.p. view. We subdivided the images into four sectors: A corresponds to the femoral neck stump, B to the bony stock cranial (=1) and caudal (=2) to the mandrel of the prosthesis, C is the region above and under the bolt and D the cortical area around the lateral plate. Radiolucencies were especially seen in sector A (A 1 = 34.7 %; A 2 = 18%) and sector C (44 %). As a pathological finding, we saw progressive radiolucencies of sector B (6 %), which were interpreted to be a sign of loosening, when they showed a thickness of = 2 mm. Furthermore, in some cases we observed extended atrophy under the lateral plate, which was also judged to be a sign of loosening. The radiological changes of the bony stock of the TPP can be divided into physiological adaptation processes because of changed biomechanics and signs of loosening. As a stress-shielding phenomenon we see a progressive atrophy under the thrust plate and simultaneously a sclerosis of the spongious bone above the calcar femoris. An indication for a loosening of the prosthesis is a progressive radiolucency of sector B.

  1. Subcutaneous Venous Port Implantation in Patients with Bilateral Breast Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peynircioglu, Bora, E-mail: borapeynir@gmail.com; Arslan, E. Bengi; Cil, Barbaros E.

    2007-06-15

    The purpose of this study was to evaluate the long-term follow-up results of subcutaneous venous ports implanted in patients with bilateral mastectomies. We retrospectively reviewed the hospital charts and the electronic database of 17 patients with bilateral mastectomies whom had venous port implantation in our interventional radiology suit. A total of 17 ports were implanted to the paramedian (n = 3) and anterolateral (standard; n = 12) chest wall, on the trapezius muscle (n = 1), and to the antecubital fossa (n = 1). The mean age was 48.29 years (range: 35-60 years). The mean time interval from time ofmore » surgery to port implantation was 34 months (range: 1-84 months). The mean follow-up time was 15 months (range: 7-39 months). Follow-up parameters and classification of the complications was defined according to the SIR guidelines. No procedure-related complication occurred. A single case of mild late infection was noted and the infection rate was 0.19/1000 catheter days. Infusion chemotherapy administration was still going on in eight patients. Two patients died during the follow-up and four patients were lost after 6 months. Port removal was performed in three patients at follow-up because of the end of treatment. One trapezius port and one paramedian port weres among the removed ports without any problem. Although we have a limited number of patients, port placement to the anterior chest wall, either paramedian or anterolateral, on the trapezius muscle or to the antecubital fossa depending on the extent of the bilateral breast surgeries that can be performed with low complication rates by a careful patient and anatomical location selection by involving the patients in the decision-making process. We believe that patient education and knowledge of possible complications have high importance in follow-up.« less

  2. Metastatic Breast Cancer in Medication-Related Osteonecrosis Around Mandibular Implants.

    PubMed

    Favia, Gianfranco; Tempesta, Angela; Limongelli, Luisa; Crincoli, Vito; Piattelli, Adriano; Maiorano, Eugenio

    2015-09-15

    Many authors have considered dental implants to be unrelated to increased risk of medication-related osteonecrosis of the jaw (MRONJ). Nevertheless, more recently, more cases of peri-implant MRONJ (PI-MRONJ) have been described, thus becoming a challenging health problem. Also, metastatic cancer deposits are not infrequently found at peri-implant sites and this may represent an additional complication for such treatments. We present the case of a breast cancer patient with PI-MRONJ, presenting a clinically and radiologically undetected metastasis within the necrotic bone, and highlight the necessity of an accurate histopathological analysis. A 66-year-old female patient, who had received intravenous bisphosphonates for bone breast cancer metastases, came to our attention for a non-implant surgery-triggered PI-MRONJ. After surgical resection of the necrotic bone, conventional and immunohistochemical examinations were performed, which showed breast cancer deposits within the necrotic bone. Cancer patients with metastatic disease, who are undergoing bisphosphonate treatment, may develop unusual complications, including MRONJ, which is a site at risk for hosting additional metastatic deposits that may be clinically and radiologically overlooked. Such risk is increased by previous or concomitant implant procedures. Consequently, clinicians should be prudent when performing implant surgery in cancer patients with advanced-stage disease and consider the possible occurrence of peri-implant metastases while planning adequate treatments in such patients.

  3. Short Dental Implants Retaining Two-Implant Mandibular Overdentures in Very Old, Dependent Patients: Radiologic and Clinical Observation Up to 5 Years.

    PubMed

    Maniewicz, Sabrina; Buser, Ramona; Duvernay, Elena; Vazquez, Lydia; Loup, Angelica; Perneger, Thomas V; Schimmel, Martin; Müller, Frauke

    To describe the survival rate and peri-implant bone loss in very old patients dependent for their activities of daily living (ADL), treated with mandibular two-implant overdentures (IODs) in the context of a previously reported randomized controlled trial. A total of 19 patients received two interforaminal Straumann implants (Regular Neck, 4.1 mm diameter, 8 mm length) that were subsequently loaded with Locator attachments, transforming their preexisting inferior conventional denture into an IOD. The primary outcome measures were implant survival rate and radiographically assessed peri-implant bone loss. Secondary outcome measures included peri-implant probing depth and Plaque Index scores, as well as implant mobility. Nutritional state (body mass index and blood markers) and cognitive state (Mini-Mental State Examination) were also analyzed. The patient cohort comprised eight men and 11 women with a mean age of 85.7 ± 6.6 years. The implant survival rate up to 5 years was 94.7%, with one early and one late implant failure. The mean loss of peri-implant bone height was 0.17 mm per year (95% confidence interval: 0.09 to 0.24; P < .001). Peri-implant probing depth and Plaque Index scores were low and stable during the first 2 years, and thereafter increased continuously. Correlation analysis suggests that a reduced cognitive function and nutritional state are not a particular risk factor for accelerated peri-implant bone loss. The high implant survival and acceptable peri-implant health suggest that neither age nor dependency for the ADLs is a contraindication for the placement of implants. Nevertheless, close monitoring of the patients concerning a potential further functional decline precluding denture management and performing oral hygiene measures is advised.

  4. Cochlear implantation in children with Jervell and Lange-Nielsen syndrome - a cautionary tale.

    PubMed

    Broomfield, Stephen J; Bruce, Iain A; Henderson, Lise; Ramsden, Richard T; Green, Kevin M J

    2012-08-01

    Jervell and Lange-Nielsen (JLN) syndrome is a rare cause of congenital profound hearing loss associated with a prolonged QT interval on the electrocardiogram. Children presenting for cochlear implantation with this condition may be asymptomatic but are at risk of sudden death. SCREENING AND SUBSEQUENT: careful management is therefore required to ensure a successful outcome. We present our experience of cochlear implantation in children with JLN syndrome, including two who died unexpectedly, and suggest a protocol for management of such cases. Clinical presentation Four cases of cochlear implantation in JLN syndrome are described. None had any previous cardiological family history. Two were diagnosed pre-operatively but, despite appropriate management under a cardiologist, died from cardiac arrest; the first in the perioperative period following reimplantation for infection, and the second unrelated to his cochlear implant surgery. The other two patients were diagnosed only subsequent to their implantation and continue to use their implants successfully. These cases highlight the variation in presentation of JLN syndrome, and the spectrum of disease severity that exists. Our protocol stresses the importance of careful assessment and counselling of parents by an experienced implant team.

  5. Gross, radiology and ultrasonographic evaluation of coral post-implantation in sheep femur.

    PubMed

    Fadilah, A; Zuki, A B Z; Loqman, M Y; Zamri-Saad, M; Norimah, Y; Asnah, H

    2004-05-01

    The study was carried out to evaluate macroscopically the ability of coral to repair a large size bone defect. A total 12 adult, male sheep were used in the study. The large bone defect (2.5cm x 0.5cm x 0.5cm) was created surgically on the left proximal femur and replaced by a block of coral (Porites sp.). Radiographs were obtained immediately after surgery and at 2, 4, 8 and 12 weeks post-implantation. Ultrasonographic examinations were carried out every 2 weeks after implantation up to 12 weeks using ultrasound machine (TOSHIBA Capasee II) connected with 7MHz frequency transducer. The sheep were euthanased at 2, 4, 8, and 12 weeks post-implantation and the bone examined grossly. Both ultrasonographs and radiographs taken at 8 and 12 weeks showed that the implants had been resorbed and left the space that much reduced in size. There was no sign of implant rejection observed in all animals. The results showed that processed coral has potential to become bone substitute for reconstructive bone surgery.

  6. Radiological Control Center (RADCC) Renaming Ceremony

    NASA Image and Video Library

    2017-03-31

    Myrna Scott holds a replica of the emblem noting that the Radiological Control Center at NASA's Kennedy Space Center has been named in honor of her husband, Randy Scott who died last year. A ceremony honored the extensive contributions of Randy Scott. A professional health physicist of more than 40 years, Scott served as the Florida spaceport's Radiation Protection Officer for 14 years until his death June 17, 2016.

  7. Sudden cardiac death: a critical appraisal of the implantable cardioverter defibrillator.

    PubMed

    Rajabali, A; Heist, E K

    2014-04-01

    Approximately 350,000 Americans still die of sudden cardiac death each year. This exceeds the number of patients who die annually from stroke, lung cancer, breast cancer and AIDS combined. This review aims to trace the history of implantable cardioverter defibrillators (ICD) with reference to landmark trials and their influence on the formulation of Medicare guidelines for ICD implantation criteria. This paper will also discuss the cost-effectiveness of ICDs and the quality of life after implantation. The reasons for the disparity between guidelines for implantation and actual clinical practice will be elucidated, with suggestions for improving overall clinical performance. The ICD has been shown to be cost-effective in reducing sudden cardiac death and all-cause mortality. However, the existing recommendations for ICD implantation have yet to translate completely into clinical practice. Barriers to implementation of existing guidelines include knowledge gaps in the referring physician practices, lack of validated screening tools to assess patient candidacy for the device and patient understanding of the need for the device. Future strategies to increase compliance with the existing guidelines and improve clinical performance are areas of potential research focus. © 2013 John Wiley & Sons Ltd.

  8. GAVeCeLT* consensus statement on the correct use of totally implantable venous access devices for diagnostic radiology procedures.

    PubMed

    Bonciarelli, Giorgio; Batacchi, Stefano; Biffi, Roberto; Buononato, Massimo; Damascelli, Bruno; Ghibaudo, Flavio; Orsi, Franco; Pittiruti, Mauro; Scoppettuolo, Giancarlo; Verzè, Alessia; Borasi, Guido; De Cicco, Marcello; Dosio, Roberto; Gazzo, Paolo; Maso, Renzo; Roman, Alessandro; Ticha, Vladimira; Venier, Giacomo; Blackburn, Paul; Goossens, Godelieve A; Bowen Santolucito, Jamie; Stas, Marguerite; Van Boxtel, Ton; Vesely, Thomas M; de Lutio, Enrico

    2011-01-01

    The use of totally implantable venous access devices in radiology may be associated with complications such as occlusion of the system (because of the high density of some contrast), infection (if the port is not handled in aseptic conditions, using proper barrier protections), and mechanical complications due to the high-pressure administration of contrast by automatic injectors (so-called power injector), including extravasation of contrast media into the soft tissues, subintimal venous or myocardial injection, or serious damage to the device itself (breakage of the external connections, dislocation of the non-coring needle, or breakage of the catheter). The last problem - i.e., the damage of the device from a power injection - is not an unjustified fear, but a reality. A warning by the US Food and Drug Administration of July 2004 reports around 250 complications of this kind, referring to both port and central venous catheters and peripherally inserted central catheter systems, which occurred over a period of several years; in all cases, the damage occurred during the injection of contrast material by means of power injectors for computed tomography or magnetic resonance imaging procedures. Though the risk associated with the use of ports in radiodiagnostics is thus clear, it has been suggested that administration of the contrast material via the port may have some advantage in terms of image quality, increased comfort for the patient, and maybe more accurate reproducibility of the patient's own follow-up exams. This contention needs to be supported by evidence. Also, since many cancer patients who need frequent computed tomography studies already have totally implantable systems, it would seem reasonable to try to define how and when such systems may safely be used. The purpose of this consensus statement is to define recommendations based on the best available evidence, for the safe use of implantable ports in radiodiagnostics.

  9. Vertebroplasty and interventional radiology procedures for bone metastases.

    PubMed

    Laredo, Jean-Denis; Chiras, Jacques; Kemel, Salim; Taihi, Lokmane; Hamze, Bassam

    2018-03-01

    Advances in cancer treatments have lengthened the survival of patients with bone metastases. Optimal control of the symptoms and prevention of the complications associated with bone metastases improve quality of life. Achieving these goals increasingly involves interventional radiology procedures. These include bone consolidation and analgesic techniques such as cementoplasty (vertebroplasty at the spine); percutaneous implantation of screws, metallic reinforcement devices, or intraosseous implants; and tumor destruction using thermal methods (radiofrequency and cryotherapy), chemicals (alcohol), and drugs (chemoembolization), which have fewer indications. Here, these techniques and their indications are reviewed. Copyright © 2017. Published by Elsevier SAS.

  10. A Prospective Study of Clinical and Radiological Outcomes of Zero-Profile Cage Screw Implants for Single-Level Anterior Cervical Discectomy and Fusion: Is Segmental Lordosis Maintained at 2 Years?

    PubMed

    Basu, Saumyajit; Rathinavelu, Sreeramalingam

    2017-04-01

    Prospective cohort study. To study clinicoradiological parameters of zero-profile cage screw used for anterior cervical discectomy and fusion (ACDF). Radiological parameters of various implants used for ACDF are available, but those for zero-profile cage are sparse. Patients with unilateral intractable brachialgia due to single-level cervical disc prolapse between April 1, 2011 and March 31, 2014 were included. Clinical assessment included arm and neck pain using visual analogue score (VAS) and neck disability index (NDI) scores. Radiological assessment included motion segment height, adjacent disc height (upper and lower), segmental and cervical lordosis, implant subsidence, and pseudoarthrosis. Follow-ups were scheduled at 1, 3, 6, 12, and 24 months. Thirty-four patients (26 males, 8 females) aged 30-50 years (mean, 42.2) showed excellent clinical improvement based on VAS scores (7.4-0 for arm and 2.0-0.6 for neck pains). Postoperative disc height improved by 11.33% ( p <0.001), but at 2 years, the score deteriorated by 7.03% ( p <0.001). Difference in the adjacent segment disc height at 2 years was 0.08% ( p =0.8) in upper and 0.16% ( p <0.001) in lower disc spaces. Average segmental lordosis achieved was 5.59° ( p <0.001) from a preoperative kyphosis of 0.88°; at 2 years, an average loss of 7.05° ( p <0.001) occurred, resulting in an average segmental kyphosis of 1.38°. Cervical lordosis improved from 11.59° to 14.88° ( p =0.164), and at 2 years, it progressively improved to 22.59° ( p <0.001). Three patients showed bone formation and two mild protrusion of the implant at 2 years without pseudoarthrosis/implant failure. The zero-profile cage screw device provides good fusion and cervical lordosis but is incapable of maintaining the segmental lordosis achieved up to a 2-year follow-up. We also recommend caution when using it in patients with small vertebrae.

  11. Beyond The Anticipatory Corpse: Medicine, Power, and the Care of the Dying: A Theoretical and Methodological Intervention into the Sociology of Brain Implant Surgery.

    PubMed

    Hancock, Black Hawk; Morrison, Daniel R

    2016-12-01

    Drawing on and extending the Foucaultian philosophical framework that Jeffrey Bishop develops in his masterful book, The Anticipatory Corpse: Medicine, Power, and the Care of the Dying, we undertake a sociological analysis of the neurological procedure-deep brain stimulation (DBS)-which implants electrodes in the brain, powered by a pacemaker-like device, for the treatment of movement disorders. Following Bishop's work, we carry out this analysis through a two-fold strategy. First, we examine how a multidisciplinary team evaluates candidates for this implant at a major medical center. We present excerpts from an ethnographic study of the "case conference" where disease entities are presented, contested, ratified, and made objects for intervention with this technology. The case conference becomes the key site in the transition from "person-with-illness" to "person-with-brain-implant" as a team of health professionals determines a plan of action by interpreting both statistical and "quality of life" data regarding their patients. Second, this article explores these decision-making processes through Bishop's conceptualization of evidence-based medicine, which relies on statistical approaches as the ultimate authority in knowledge production and medical decisions. We then reflect on Bishop's critique of the social sciences and the methodological, analytical, and substantive ramifications that The Anticipatory Corpse can offer future sociological work. © The Author 2016. Published by Oxford University Press, on behalf of the Journal of Medicine and Philosophy Inc. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Transapical aortic valve implantation in Rouen: four years' experience with the Edwards transcatheter prosthesis.

    PubMed

    Litzler, Pierre-Yves; Borz, Bogdan; Smail, Hassiba; Baste, Jean-Marc; Nafeh-Bizet, Catherine; Gay, Arnaud; Tron, Christophe; Godin, Matthieu; Caudron, Jerome; Hauville, Camille; Dacher, Jean-Nicolas; Cribier, Alain; Eltchaninoff, Hélène; Bessou, Jean-Paul

    2012-03-01

    The first French transapical transcatheter aortic valve implantation (TAVI) was performed in July 2007 in our department. To report 4-year outcomes of transapical implantation with the Edwards transcatheter bioprosthesis. We prospectively evaluated consecutive patients who underwent transapical implantation with an Edwards transcatheter bioprosthesis between July 2007 and October 2011. Patients were not suitable for conventional surgery (due to severe comorbidities) or transfemoral implantation (due to poor femoral access). Among 61 patients (59.0% men), mean logistic EuroSCORE was 27.5 ± 14.9% and mean age was 81.0 ± 6.8 years. Successful valve implantation was achieved in 59/61 patients (96.7%) of patients. The other two patients required conversion to conventional surgery due to prosthesis embolization and died. Six additional patients died in the postoperative period. Causes of perioperative death were two septic shocks (one of peritonitis), two multi-organ failure, one ventricular fibrillation and one respiratory insufficiency. Intraprocedural stroke was not observed in any patient. The actuarial survival rates at 1, 2 and 4 years were 73.8%, 67.2% and 41.0%. During this 4-year period, four patients died of cardiovascular events, but no impairment of transprosthesis gradient was observed. Our series of 61 patients who underwent transapical implantation of the Edwards transcatheter bioprosthesis shows satisfactory results, similar to other reports, considering the high level of severity of patients referred for this method. Transapical access is a reliable alternative method for patients that cannot benefit from a transfemoral approach. Copyright © 2012. Published by Elsevier Masson SAS.

  13. Dual-modal photoacoustic and ultrasound imaging of dental implants

    NASA Astrophysics Data System (ADS)

    Lee, Donghyun; Park, Sungjo; Kim, Chulhong

    2018-02-01

    Dental implants are common method to replace decayed or broken tooth. As the implant treatment procedures varies according to the patients' jawbone, bone ridge, and sinus structure, appropriate examinations are necessary for successful treatment. Currently, radiographic examinations including periapical radiology, panoramic X-ray, and computed tomography are commonly used for diagnosing and monitoring. However, these radiographic examinations have limitations in that patients and operators are exposed to radioactivity and multiple examinations are performed during the treatment. In this study, we demonstrated photoacoustic (PA) and ultrasound (US) combined imaging of dental implant that can lower the total amount of absorbed radiation dose in dental implant treatment. An acoustic resolution PA macroscopy and a clinical PA/US system was used for dental implant imaging. The acquired dual modal PA/US imaging results support that the proposed photoacoustic imaging strategy can reduce the radiation dose rate during dental implant treatment.

  14. Accuracy of vertical height measurements on direct digital panoramic radiographs using posterior mandibular implants and metal balls as reference objects.

    PubMed

    Vazquez, L; Nizamaldin, Y; Combescure, C; Nedir, R; Bischof, M; Dohan Ehrenfest, D M; Carrel, J-P; Belser, U C

    2013-01-01

    Conventional panoramic radiography, a widely used radiographic examination tool in implant treatment planning, allows evaluation of the available bone height before inserting posterior mandibular implants. Image distortion and vertical magnification due to projection geometry is well described for rotational panoramic radiographs. To assess the accuracy of vertical height measurements on direct digital panoramic radiographs, implants and metal balls positioned in the posterior mandible were used as radio-opaque reference objects. The reproducibility of the measuring method was assessed by the inter- and intraobserver agreements. Direct digital panoramic radiographs, performed using a Kodak 8000C (Eastman Kodak Company, Rochester, NY), of 17 partially edentulous patients (10 females, 7 males, mean age 65 years) were selected from an X-ray database gathered during routine clinical evaluation of implant sites. Proprietary software and a mouse-driven calliper were used to measure the radiological length of 25 implants and 18 metal reference balls, positioned in mandibular posterior segments. The distortion ratio (DR) was calculated by dividing the radiological implant length by the implant's real length and the radiological ball height by the ball's real height. Mean vertical DR was 0.99 for implants and 0.97 for balls, and was unrelated to mandibular sites, side, age, gender or observer. Inter- and intraobserver agreements were acceptable for both reference objects. Vertical measurements had acceptable accuracy and reproducibility when a software-based calibrated measurement tool was used, confirming that digital panoramic radiography can be reliably utilized to determine the pre-operative implant length in premolar and molar mandibular segments.

  15. Correlation between thigh pain and radiological findings with a proximally porous-coated stem.

    PubMed

    Kinov, Plamen; Radl, Roman; Zacherl, Maximilian; Leithner, Andreas; Windhager, Reinhard

    2007-10-01

    Thigh pain has been consistently reported with cementless hip arthroplasty. The correlation between thigh pain and radiological findings and the clinical significance of thigh pain have not been studied in any detail. We carried out a retrospective study to analyse the performance of a proximally porous-coated cementless femoral component. Ninety-eight total hip arthroplasties were followed up clinically and radiologically for an average of 33 months (range: 12 to 64) after operation. The clinical results were good or excellent in 85 cases (87%). Thirteen patients (13%) reported thigh pain at latest follow-up. Subsidence of the stem was recorded in 10 cases, cortical thickening occurred in 14 hips (14%), and 17 hips (17%) presented proximal osteopenia. Proximally, radiolucent lines were observed in 11 cases. Thigh pain correlated with radiolucent lines, femoral thickening, fibrous fixation and stem migration. Bone remodelling was noted to continue even five years after implantation. Our observations demonstrated bone ingrowth in the majority of the cases and a low incidence of thigh pain. The correlation between radiological changes and thigh pain suggests implant micromotion and migration in some hips. Patients with thigh pain, changes in the proximal femur and progressive subsidence need further clinical and radiological follow-up.

  16. Radiological and micro-computed tomography analysis of the bone at dental implants inserted 2, 3 and 4 mm apart in a minipig model with platform switching incorporated.

    PubMed

    Elian, Nicolas; Bloom, Mitchell; Dard, Michel; Cho, Sang-Choon; Trushkowsky, Richard D; Tarnow, Dennis

    2014-02-01

    = 0.1699). BV/TV inside the defined parallelepipedic masks reached 82.38% for the 2 mm inter-implant distance and 85.00% for 3 mm, P = 0.8432. For the comparison of the 3-4 mm inter-implant distance, the means were 84.69% and 84.38%, respectively, P = 0.8401. Non-inferiority tests for the smaller inter-implant distances for both comparisons showed similar differences and similar tolerance ranges. The effect of a smaller interproximal distances between implants on bone level, fBIC and BV/TV assessed by two convergent investigation methods, radiology and μCT, was similar to that of larger distances. Implants can potentially be placed 2 mm apart instead of 3 mm and 3 mm apart instead of 4 mm when platform switching is utilized. Further research with a conventional platform is warranted. © 2012 John Wiley & Sons A/S.

  17. Periapical implant lesion: A systematic review

    PubMed Central

    Blaya-Tárraga, Juan-Antonio; Cervera-Ballester, Juan; Peñarrocha-Oltra, David; Peñarrocha-Diago, Miguel

    2017-01-01

    Background The aim of this study was to systematically review the evidence for periapical implant lesion, which makes a patient more susceptible to the periapical lesion, frequency, symptoms, signs (including radiological findings) and possible treatment options. Material and Methods A systematic literature review and analysis of publications included in PubMed, Embase and Cochrane; articles published until March 2016; with a populations, exposures and outcomes (PEO) search strategy was performed, focused on the issue: “In patients with periapical lesion to the implant during the osseointegration, what symptoms, signs, and changes in complementary examination manifested, for according to that stage, be intervened with the appropriate approach?”. The set criteria for inclusion were peer-reviewed articles. Results From a total of 212 papers identified, 36 studies were included in this systematic review, with 15461 implants evaluated and 183 periapical implant lesions. Which 8 papers included more than 5 cases and 28 included equal or less than 5 cases. Analysis of the papers revealed that periapical implant lesion is classified according to evolution stages into acute (non-suppurated and suppurated) and subacute (or suppurated-fistulized). In the acute stage and in the subacute if there is no loss of implant stability, the correct treatment approach is implant periapical surgery. In the subacute stage associated with implant mobility the implant must be removed. Conclusions Evidence on the subject is very limited, there are few studies with small sample, without homogeneity of criteria for diagnosing the disease and without design of scientific evidence. Currently etiology lacks consensus. The early diagnosis of periapical implant periapical lesions during the osseointegration phase and early treatment, will lead to a higher survival rate of implants treated, hence preventing the need for implant extraction. Key words:Apical peri-implantitis, retrograde peri-implantitis

  18. Modified endoscopic medial maxillectomy for zygomatic implant salvage.

    PubMed

    Schwartz, Joseph S; Tajudeen, Bobby A; Adappa, Nithin D; Palmer, James N

    2016-01-01

    Odontogenic chronic rhinosinusitis (CRS) is an epidemiologically important disease process due, in part, to the increasingly commonplace use of dental restorative procedures such as zygomatic implantation. Traditional management of this clinical entity typically entails extraction of the infected hardware via an open or endoscopic approach. We describe a novel management strategy of odontogenic CRS following bilateral zygomatic implantation for oral rehabilitation that we surgically salvaged via a modified endoscopic medial maxillectomy. We describe the presentation and management of a case of metachronous development of bilateral CRS subsequent to zygomatic implantation. The patient's postoperative course was characterized by marked endoscopic, radiologic, and symptomatic improvement as measured by the 22-item Sino-Nasal Outcome Test. We describe a novel treatment strategy for the management of odontogenic sinusitis resulting from erroneous zygomatic implant placement. Modified endoscopic medial maxillectomy in this clinical context facilitates mucosal normalization of the affected sinus, while permitting preservation of oral function through salvage of the displaced implant.

  19. Modified endoscopic medial maxillectomy for zygomatic implant salvage

    PubMed Central

    Tajudeen, Bobby A.; Adappa, Nithin D.; Palmer, James N.

    2016-01-01

    Objectives: Odontogenic chronic rhinosinusitis (CRS) is an epidemiologically important disease process due, in part, to the increasingly commonplace use of dental restorative procedures such as zygomatic implantation. Traditional management of this clinical entity typically entails extraction of the infected hardware via an open or endoscopic approach. We describe a novel management strategy of odontogenic CRS following bilateral zygomatic implantation for oral rehabilitation that we surgically salvaged via a modified endoscopic medial maxillectomy. Methods: We describe the presentation and management of a case of metachronous development of bilateral CRS subsequent to zygomatic implantation. Results: The patient's postoperative course was characterized by marked endoscopic, radiologic, and symptomatic improvement as measured by the 22-item Sino-Nasal Outcome Test. Conclusion: We describe a novel treatment strategy for the management of odontogenic sinusitis resulting from erroneous zygomatic implant placement. Modified endoscopic medial maxillectomy in this clinical context facilitates mucosal normalization of the affected sinus, while permitting preservation of oral function through salvage of the displaced implant. PMID:28107147

  20. Custom implant design for large cranial defects.

    PubMed

    Marreiros, Filipe M M; Heuzé, Y; Verius, M; Unterhofer, C; Freysinger, W; Recheis, W

    2016-12-01

    The aim of this work was to introduce a computer-aided design (CAD) tool that enables the design of large skull defect (>100 [Formula: see text]) implants. Functional and aesthetically correct custom implants are extremely important for patients with large cranial defects. For these cases, preoperative fabrication of implants is recommended to avoid problems of donor site morbidity, sufficiency of donor material and quality. Finally, crafting the correct shape is a non-trivial task increasingly complicated by defect size. We present a CAD tool to design such implants for the neurocranium. A combination of geometric morphometrics and radial basis functions, namely thin-plate splines, allows semiautomatic implant generation. The method uses symmetry and the best fitting shape to estimate missing data directly within the radiologic volume data. In addition, this approach delivers correct implant fitting via a boundary fitting approach. This method generates a smooth implant surface, free of sharp edges that follows the main contours of the boundary, enabling accurate implant placement in the defect site intraoperatively. The present approach is evaluated and compared to existing methods. A mean error of 89.29 % (72.64-100 %) missing landmarks with an error less or equal to 1 mm was obtained. In conclusion, the results show that our CAD tool can generate patient-specific implants with high accuracy.

  1. Induction of periimplantitis in dental implants.

    PubMed

    Becker, Stephan T; Föge, Marc; Beck-Broichsitter, Benedicta E; Gavrilova, Olga; Bolte, Hendrik; Rosenstiel, Philipp; Wiltfang, Jörg

    2013-01-01

    Development, progression, and therapy of periimplantitis are nonresolved emerging problems. The aim of this pilot study was to establish a model for periimplantitis in mice to have a base for tests with immune-deficient knockout organisms to improve the knowledge about development and progression of periimplantitis and to develop further therapeutic options.In 8 mice, titanium implants were inserted in the median of the palate. Four of these implants had ligatures (periimplantitis group). After 2 weeks, the animals received a special diet enriched with sugar and flavor. After 9 weeks, micro-computed tomography (micro-CT) examinations to evaluate the periimplant tissue and histologies were performed.Dental implant insertions within the oral cavity are possible in living mice. Implants with ligatures showed significantly larger periimplant bone defects than controls. The radiologic findings were confirmed by histology. At the end of the observation period, the portion of implants lost was higher in the ligature group.This is the first publication to describe the insertion of dental implants in living mice. In addition, it is the first time that periimplant infection could be induced in that species. This model will pave the way to study knockout mice with reduced or even enhanced resistance to periimplantitis.

  2. Herbert M. Parker: Publications and contributions to radiological and health physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kathren, R.L.; Baalman, R.W.; Bair, W.J.

    For more than a half century, Herbert M. Parker was a leading force in radiological physics. As a scientist, he was codeveloper of a systematic dosimetry scheme for implant therapy and the innovative proposer of radiological units with unambiguous physical and biological bases. He made seminal contributions to the development of scientifically based radiation protection standards and, as an administrator and manager as well as scientist, helped the Hanford Laboratories to achieve preeminance in several areas, including radiation biology, radioactive waste disposal, and environmental radioactivity. This volume brings together, sometimes from obscure sources, his works.

  3. [Brief history of interventional radiology].

    PubMed

    Tang, Zhenliang; Jia, Aiqin; Li, Luoyun; Li, Chunyu

    2014-05-01

    In 1923, angiography was first successively used for the human body. In 1953, a Swedish doctor Sven-Ivar Seldinger pioneered the Seldinger technique, which laid down the foundation of interventional radiology. In 1963, Charles Dotter first proposed the idea of interventional radiology. In 1964, Charles Dotter opened a new era of percutaneous angioplasty through accidental operation, marking the formation of interventional radiology. On this basis, the techniques of balloon catheter dilation and metal stent implantation was developed. Endovascular stent was proposed in 1969. In 1973, the percutaneous angioplasty has been a breakthrough with the emergence of soft double-lumen balloon catheter. Percutaneous coronary angioplasty is applied in 1977. Since the 1990s, balloon angioplasty relegated to secondary status with the emergence of metal stent. Currently, endovascular stent have entered a new stage with the emergence of temporary stent and stent grafts and biological stent. Transcatheter arterial embolization had been one of the most important basic techniques for interventional radiology since 1965, it had also been a corresponding development with the improvement of embolic agents and catheter technology for the treatment of diseases now. Transjugular intrahepatic portosystemic stent-shunt is a comprehensive interventional radiology technology since 1967, in which the biliary system can be reached through a jugular vein, and the improvement appeared with balloon expandable stent in 1986.Since 1972, non-vascular interventional techniques was another important branch of interventional radiology. Currently, it is applied in the diagnosis and treatment of many diseases of the internal organs like the pancreas, liver, kidney, spinal cord, Fallopian tubes, esophagus and other organs. In 1973, Chinese radiologist first conducted the angiography test. Interventional radiology was introduced into China in the 1980s, it was readily developed through the sponsoring of

  4. Evaluating cochlear implant trauma to the scala vestibuli.

    PubMed

    Adunka, O; Kiefer, J; Unkelbach, M H; Radeloff, A; Gstoettner, W

    2005-04-01

    Placement of cochlear implant electrodes into the scala vestibuli may be intentional, e.g. in case of blocked scala tympani or unintentional as a result of trauma to the basilar membrane or erroneous location of the cochieostomy. The aim of this study was to evaluate the morphological consequences and cochlear trauma after implantation of different cochlear implant electrode arrays in the scala vestibuli. Human temporal bone study with histological and radiological evaluation. Twelve human cadaver temporal bones were implanted with different cochlear implant electrodes. Implanted bones were processed using a special method to section undecalcified bone. Cochlear trauma and intracochlear positions. All implanted electrodes were implanted into the scala vestibuli using a special approach that allows direct scala vestibuli insertions. Fractures of the osseous spiral lamina were evaluated in some bones in the basal cochlear regions. In most electrodes, delicate structures of the organ of Corti were left intact, however, Reissner's membrane was destroyed in all specimens and the electrode lay upon the tectorial membrane. In some bones the organ of Corti was destroyed. Scala vestibuli insertions did not cause severe trauma to osseous or neural structures, thus preserving the basis for electrostimulation of the cochlea. However, destruction of Reissner's membrane and impact on the Organ of Corti can be assumed to destroy residual hearing.

  5. Ultrafine-grained titanium for medical implants

    DOEpatents

    Zhu, Yuntian T.; Lowe, Terry C.; Valiev, Ruslan Z.; Stolyarov, Vladimir V.; Latysh, Vladimir V.; Raab, Georgy J.

    2002-01-01

    We disclose ultrafine-grained titanium. A coarse-grained titanium billet is subjected to multiple extrusions through a preheated equal channel angular extrusion (ECAE) die, with billet rotation between subsequent extrusions. The resulting billet is cold processed by cold rolling and/or cold extrusion, with optional annealing. The resulting ultrafine-grained titanium has greatly improved mechanical properties and is used to make medical implants.

  6. Maintaining Low Voiding Solder Die Attach for Power Die While Minimizing Die Tilt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamm, Randy; Peterson, Kenneth A.

    2015-10-01

    This paper addresses work to minimize voiding and die tilt in solder attachment of a large power die, measuring 9.0 mm X 6.5 mm X 0.1 mm (0.354” x 0.256” x 0.004”), to a heat spreader. As demands for larger high power die continue, minimizing voiding and die tilt is of interest for improved die functionality, yield, manufacturability, and reliability. High-power die generate considerable heat, which is important to dissipate effectively through control of voiding under high thermal load areas of the die while maintaining a consistent bondline (minimizing die tilt). Voiding was measured using acoustic imaging and die tiltmore » was measured using two different optical measurement systems. 80Au-20Sn solder reflow was achieved using a batch vacuum solder system with optimized fixturing. Minimizing die tilt proved to be the more difficult of the two product requirements to meet. Process development variables included tooling, weight and solder preform thickness.« less

  7. Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial.

    PubMed

    Aunmeungtong, Weerapan; Kumchai, Thongnard; Strietzel, Frank P; Reichart, Peter A; Khongkhunthian, Pathawee

    2017-04-01

    Dental implant-retained overdentures have been chosen as the treatment of choice for complete mandibular removable dentures. Dental implants, such as mini dental implants, and components for retaining overdentures, are commercially available. However, comparative clinical studies comparing mini dental implants and conventional dental implants using different attachment for implant-retained overdentures have not been well documented. To compare the clinical outcomes of using two mini dental implants with Equator ® attachments, four mini dental implants with Equator attachments, or two conventional dental implants with ball attachments, by means of a randomized clinical trial. Sixty patients received implant-retained mandibular overdentures in the interforaminal region. The patients were divided into three groups. In Groups 1 and 2, two and four mini dental implants, respectively, were placed and immediately loaded by overdentures, using Equator ® attachments. In Group 3, conventional implants were placed. After osseointegration, the implants were loaded by overdentures, using ball attachments. The study distribution was randomized and double-blinded. Outcome measures included changes in radiological peri-implant bone level from surgery to 12 months postinsertion, prosthodontic complications and patient satisfaction. The cumulative survival rate in the three clinical groups after one year was 100%. There was no significant difference (p < 0.05) in clinical results regarding the number (two or four) of mini dental implants with Equator attachments. However, there was a significant difference in marginal bone loss and patient satisfaction between those receiving mini dental implants with Equator attachments and conventional dental implants with ball attachments. The marginal bone resorption in Group 3 was significantly higher than in Groups 1 and 2 (p < 0.05); there were no significant differences between Groups 1 and 2. There was no significant difference in

  8. Immediate Functional Loading of One-Piece Zirconia Implants in a Full-Arch Maxillary Restoration: A Five-Year Case Report.

    PubMed

    Peter, Burghard

    Immediate loading has proven to be a predictable modality for restorations with titanium dental implants. An increasing number of articles indicate that zirconia implants might osseointegrate to a similar extent in this context. This 5-year case report describes an outpatient maxillary restoration with eight immediately loaded zirconia implants. Implantation followed extensive bone augmentation. At the 5-year follow-up, all implants were still well osseointegrated clinically and radiologically. No major bone loss or peri-implantitis had occurred in spite of temporary insufficient patient compliance. More research and studies are needed to confirm these results.

  9. Cochlear implantation in Waardenburg syndrome: The Indian scenario.

    PubMed

    Deka, Ramesh Chandra; Sikka, Kapil; Chaturvedy, Gaurav; Singh, Chirom Amit; Venkat Karthikeyan, C; Kumar, Rakesh; Agarwal, Shivani

    2010-10-01

    Children with Waardenburg syndrome (WS) exhibiting normal inner ear anatomy, like those included in our cohort, derive significant benefit from cochlear implantation and results are comparable to those reported for the general population of implanted children. The patient population of WS accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with WS who have undergone cochlear implantation. On retrospective chart review, there were four cases with WS who underwent cochlear implantation. These cases were assessed for age at implantation, clinical and radiological features, operative and perioperative course, and performance outcomes. Auditory perception and speech production ability were evaluated using categories of auditory performance (CAP), meaningful auditory integration scales (MAIS), and speech intelligibility rating (SIR) during the follow-up period. In this group of children with WS, with a minimum follow-up of 12 months, the CAP score ranged from 3 to 5, MAIS from 25 to 30, and SIR was 3. These scores are comparable with those of other cochlear implantees.

  10. The Use of Interventional Radiology Techniques in the Treatment of Pancreatic Fistula.

    PubMed

    Miłek, Tomasz; Baranowski, Krzysztof; Petryka, Robert; Ciostek, Piotr

    2016-12-01

    One of the complications of pancreatic disease is the formation of pancreatic fistulae. The presence of fistula leads to body wasting and cachexia. The standard treatment is intubation of the Wirsung duct and in cases where there are no improvements the next proposed form of treatment is surgery. The aim of the study was to evaluate the efficacy of pancreatic fistula closure using interventional radiology techniques. In 2009 to 2014, 46 patients diagnosed with pancreatic fistula were treated with interventional radiology techniques. Treatment consisted of vascular coil implanted at the entry of the fistula and then sealed with tissue glue adhesive during endoscopic procedure. Technical success of vascular coil implantation and the use of tissue glue adhesive were reported in all patients. Pancreatic fistula recurred in 7 patients (15.2%). The latter group of patients underwent statistical analysis to determine what the risk factors in recurring pancreatic fistulas were. The results indicate a significant relationship between etiology of the fistula and treatment effect. (1) the use of interventional radiology methods in the closure of pancreatic fistula is an effective and safe procedure; and (2) the recurrence of fistula is dependent on the etiology and often occurs after surgery or trauma.

  11. [Initial experience of transcatheter implantation with a new aortic valve in sheep].

    PubMed

    Wang, Jian-ming; Yang, Jian; Yang, Li-fang; Zhang, Xue-xin; Hu, Yun; Liu, Jin-cheng; Yu, Shi-qiang; Yi, Ding-hua

    2011-11-01

    To evaluate the feasibility and short-term results of transcatheter aortic valve implantation (TAVI) using a new transcatheter valve. Twenty healthy adult sheep received general anesthesia. Under the guidance of X-ray and transthoracic echocardiography (TTE), the new anti-calcification transcatheter valve was released from delivery system and implanted at the level of native aortic annulus via left common carotid artery. Position and function of the new anti-calcification transcatheter valve were evaluated by angiography and TTE immediately after intervention. Thirty day survival rate of animals was obtained. New transcatheter valves were implanted in all sheep. Fifteen sheep (75%) survived up to 30 days and post-operative examination showed that the transcatheter valve was in optimal position without migration and mitral valve impingement. The native coronary artery was patent in these animals. There was a slight paravalvular leak in 5 sheep. Postoperative echocardiography showed reflux percentage was significantly increased (P < 0.05) compared pre-intervention. Effective orifice area, aortic systolic pressure, diastolic aortic pressure, mean aortic pressure, left ventricular systolic pressure, left ventricular end diastolic pressure and heart rate were similar between post and pre-intervention (all P < 0.05). Five sheep died after TAVI within 30 days, including one fatal ventricular fibrillation occurred immediately after releasing the transcatheter valve and another sheep died of acute myocardial infarction due to left main coronary artery occlusion evidenced by angiography. Two sheep died of severe mitral regurgitation at 8 and 12 hours post-operation and one died of infective endocarditis at 26 days after intervention. Our favorable preliminary results showed that it was feasible to perform TAVI using the new transcatheter valve.

  12. Accurate defect die placement and nuisance defect reduction for reticle die-to-die inspections

    NASA Astrophysics Data System (ADS)

    Wen, Vincent; Huang, L. R.; Lin, C. J.; Tseng, Y. N.; Huang, W. H.; Tuo, Laurent C.; Wylie, Mark; Chen, Ellison; Wang, Elvik; Glasser, Joshua; Kelkar, Amrish; Wu, David

    2015-10-01

    Die-to-die reticle inspections are among the simplest and most sensitive reticle inspections because of the use of an identical-design neighboring-die for the reference image. However, this inspection mode can have two key disadvantages: (1) The location of the defect is indeterminate because it is unclear to the inspector whether the test or reference image is defective; and (2) nuisance and false defects from mask manufacturing noise and tool optical variation can limit the usable sensitivity. The use of a new sequencing approach for a die-to-die inspection can resolve these issues without any additional scan time, without sacrifice in sensitivity requirement, and with a manageable increase in computation load. In this paper we explore another approach for die-to-die inspections using a new method of defect processing and sequencing. Utilizing die-to-die double arbitration during defect detection has been proven through extensive testing to generate accurate placement of the defect in the correct die to ensure efficient defect disposition at the AIMS step. The use of this method maintained the required inspection sensitivity for mask quality as verified with programmed-defectmask qualification and then further validated with production masks comparing the current inspection approach to the new method. Furthermore, this approach can significantly reduce the total number of defects that need to be reviewed by essentially eliminating the nuisance and false defects that can result from a die-to-die inspection. This "double-win" will significantly reduce the effort in classifying a die-to-die inspection result and will lead to improved cycle times.

  13. Three-dimensional plotting and printing of an implant drilling guide: simplifying guided implant surgery.

    PubMed

    Flügge, Tabea Viktoria; Nelson, Katja; Schmelzeisen, Rainer; Metzger, Marc Christian

    2013-08-01

    To present an efficient workflow for the production of implant drilling guides using virtual planning tools. For this purpose, laser surface scanning, cone beam computed tomography, computer-aided design and manufacturing, and 3-dimensional (3D) printing were combined. Intraoral optical impressions (iTero, Align Technologies, Santa Clara, CA) and digital 3D radiographs (cone beam computed tomography) were performed at the first consultation of 1 exemplary patient. With image processing techniques, the intraoral surface data, acquired using an intraoral scanner, and radiologic 3D data were fused. The virtual implant planning process (using virtual library teeth) and the in-office production of the implant drilling guide was performed after only 1 clinical consultation of the patient. Implant surgery with a computer-aided design and manufacturing produced implant drilling guide was performed during the second consultation. The production of a scan prosthesis and multiple preoperative consultations of the patient were unnecessary. The presented procedure offers another step in facilitating the production of drilling guides in dental implantology. Four main advantages are realized with this procedure. First, no additional scan prosthesis is needed. Second, data acquisition can be performed during the first consultation. Third, the virtual planning is directly transferred to the drilling guide without a loss of accuracy. Finally, the treatment cost and time required are reduced with this facilitated production process. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Biokompatible Implantate und Neuentwicklungen in der Gynäkologie

    NASA Astrophysics Data System (ADS)

    Jacobs, Volker R.; Kiechle, Marion

    Für den Einsatz in der Gynäkologie stehen heute eine Vielzahl unterschiedlicher, biokompatibler Materialien und Implantate zur Verfügung. Auf eine Auswahl soll hier näher eingegangen werden, die die verschiedenen Materialien und Bauweisen repräsentieren. So sind Brustimplantate seit fast vier Jahrzehnten im Gebrauch für die Brustvergrösserung und den Brustwiederaufbau. Material, Bauweisen und medizinische Aspekte einschliesslich der kontroversen Diskussion um Silikon werden im folgenden erläutert. Neuere Entwicklungen von Verhütungstechniken für permanente Sterilisation wie den Filshie ClipTM für transabdominalen und den STOPTM für intraluminalen Verschluss der Eileiter oder die intrauterin plazierte Hormonspirale MirenaTM für zeitlich begrenzte Verhütung werden beschrieben. Eine neue Perspektive zur Verhinderung postoperativer intraabdominaler Adhäsionen stellt Spray-GelTM, ein Zweikomponenten Hydrogel aus Polyethylenglykol, dar.

  15. Computed tomography-based evaluation of template (NobelGuide™)-guided implant positions: a prospective radiological study.

    PubMed

    Vasak, Christoph; Watzak, Georg; Gahleitner, André; Strbac, Georg; Schemper, Michael; Zechner, Werner

    2011-10-01

    This prospective study was intended to evaluate the overall deviation in a clinical treatment setting to provide for quantification of the potential impairment of treatment safety and reliability with computer-assisted, template-guided transgingival implantation. The patient population enrolled (male/female=10/8) presented with partially dentate and edentulous maxillae and mandibles. Overall, 86 implants were placed by two experienced dental surgeons strictly following the NobelGuide™ protocol for template-guided implantation. All patients had a postoperative computed tomography (CT) with identical settings to the preoperative examination. Using the triple scan technique, pre- and postoperative CT data were merged in the Procera planning software, a newly developed procedure - initially presented in 2007 allowing measurement of the deviations at implant shoulder and apex. The deviations measured were an average of 0.43 mm (bucco-lingual), 0.46 mm (mesio-distal) and 0.53 mm (depth) at the level of the implant shoulder and slightly higher at the implant apex with an average of 0.7 mm (bucco-lingual), 0.63 mm (mesio-distal) and 0.52 mm (depth). The maximum deviation of 2.02 mm was encountered in the corono-apical direction. Significantly lower deviations were seen for implants in the anterior region vs. the posterior tooth region (P<0.01, 0.31 vs. 0.5 mm), and deviations were also significantly lower in the mandible than in the maxilla (P=0.04, 0.36 vs. 0.45 mm) in the mesio-distal direction. Moreover, a significant correlation between deviation and mucosal thickness was seen and a learning effect was found over the time period of performance of the surgical procedures. Template-guided implantation will ensure reliable transfer of preoperative computer-assisted planning into surgical practice. With regard to the required verification of treatment reliability of an implantation system with flapless access, all maximum deviations measured in this clinical study were

  16. The Influence of the Crown-Implant Ratio on the Crestal Bone Level and Implant Secondary Stability: 36-Month Clinical Study.

    PubMed

    Hadzik, Jakub; Krawiec, Maciej; Sławecki, Konstanty; Kunert-Keil, Christiane; Dominiak, Marzena; Gedrange, Tomasz

    2018-01-01

    When the era of dental implantology began, the pioneers defined some gold standards used in dental prosthetics treatment for implant-supported restorations. Referring to traditional prosthetics, it was taken for granted that the length of an implant placed in the alveolar bone (the equivalent of the root) should exceed the length of the superstructure. The aim of the study was to determine whether implant length and the crown-to-implant ( C / I ) ratio influence implant stability and the loss of the surrounding marginal bone and whether short implants can be used instead of sinus augmentation procedures. The patients participating in the study ( n = 30) had one single tooth implant, a short (OsseoSpeed™ L6 Ø4 mm, Implants) or a regular implant (OsseoSpeed L11 and L13 Ø4 mm, DENTSPLY Implants), placed in the maxilla. The evaluation was based on clinical and radiological examination. The crown-to-implant ratio was determined by dividing the length of the crown together with the abutment by the length of the implant placed crestally. Mean crown-to-implant ratios were calculated separately for each group and its correlation with the MBL (marginal bone loss) and stability was assessed. The authors compared the correlation between the C / I ratio values, MBL, and secondary implant stability. Positive results in terms of primary and secondary stability were achieved with both (short and conventional) implants. The MBL was low for short and conventional implants being 0.34 ± 0.24 mm and 0.22 ± 0.46 mm, respectively. No significant correlation was found between the C / I ratio and secondary stability as well as the C / I ratio and the marginal bone loss. Short implants can be successfully used to support single crowns. The study has revealed no significant differences in the clinical performance of prosthetic restorations supported by short implants. Clinical trial registration number is NCT03471000.

  17. Treatment of carcinoma of the penis by iridium 192 wire implant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daly, N.J.; Douchez, J.; Combes, P.F.

    1982-07-01

    Since 1971, a group of 22 adult patients with squamous cell carcinoma of the penis have been treated by iridium 192 wire implants. There were 6 T1 tumors, 14 T2 tumors and 2 T3; only one patient (T3) presented with local failure after implant. Local necrosis occurred in 2 patients without local tumoral recurrence, but was sufficient enough to warrant amputation. Thus 19/22 (86%) patients were locally cured with penile conservation. In these patients the most frequent posttherapeutic complication is chronic urethral stenosis (9/19 patients, 47%) requiring repeated instrumental dilations. Four patients presented with initial inguinal mestastatic nodes; only onemore » was cured by radiosurgical treatment. Among patients without metastatic nodes at the time of diagnosis, none had delayed metastatic nodes. Three patients died of nodal evolution, 5 patients died of intercurrent disease without evidence of disease and 14 are now alive and NED. It appears that iridium 192 wire implant is the most effective conservative treatment of invasive squamous cell carcinoma of the penis; however, these results confirm that no particular treatment is required for inguinal nodal areas for patients who initially present with no disease.« less

  18. Increased crown-to-implant ratio may not be a risk factor for dental implant failure under appropriate plaque control.

    PubMed

    Okada, Shinsuke; Koretake, Katsunori; Miyamoto, Yasunari; Oue, Hiroshi; Akagawa, Yasumasa

    2013-01-01

    The aim of this study was to evaluate whether increased crown-to-implant (C/I) ratio influences implant stability or not under proper healthy control of peri-implant mucosa. The hypothesis of this study is that implant stability can be maintained despite High C/I, under appropriate plaque control. Five male Beagle-Labrador hybrid dogs (2 years old) were used. Their bilateral mandibular premolar extraction was performed. After allowing 12 weeks for bone healing, 3 types of vertical marginal bone loss were simultaneously prepared randomly. Then, 30 titanium implants were placed in the edentulous areas and defined as High C/I, Mid C/I and Low C/I groups. This time point was designated as the baseline (0 Week). Twelve weeks after implant placement, metal superstructures were cemented to the implants and an occlusal plate was set at the opposite side. At the same time, Calcein green was injected for remodeling evaluation. Implants were loaded by feeding the dogs a hard pellet diet. Tooth brushing was performed 5 days per week during the study to maintain healthy peri-implant mucosa. Twenty-four weeks following implant placement, the interface structure was evaluated clinically, radiologically, and histologically. Implant stability quotient (ISQ) increased with time in all 3 groups, without any significant correlation with the C/I value (p >0.05). Moreover, mean marginal bone loss adjacent around implants in all 3 groups ranged between 0.11 and 0.19 mm, with no significant difference (p >0.05). Many fluorescence-labeled bones are shown in the High C/I group. It is considered that high remodeling activity prevent marginal bone loss in the High C/I group and this may provide favorable implant stability under proper plaque control. These findings suggest that increased C/I may not be a risk factor for implant failure if the peri-implant mucosa is kept healthy, as was the case in this animal model.

  19. Evolution of the mandibular mesh implant.

    PubMed

    Salyer, K E; Johns, D F; Holmes, R E; Layton, J G

    1977-07-01

    Between 1960 and 1972, the Dallas Veterans Administration Hospital Maxillofacial Research Laboratory developed and made over 150 cast-mesh implants. Successive designs were ovoid, circular, and double-lumened in cross section to improve implant strength, surface area for bioattachment, and adjustability. Sleeves, collars, and bows were employed in the assembly of these implants, with an acrylic condylar head attached when indicated. In 1972, our laboratory developed a mandibular mesh tray, cast in one piece on a single sprue, with preservation of the vertically adjustable ramus. Stainless steel replaced Vitallium because of its greater malleability. Essentially, a lost-wax technique is used to cast the mesh tray. The model of a mandibular segment is duplicated as a refractory model. Mesh wax, made in our own custom-made die, is adapted to the refractory model. The unit is then sprued and invested. The wax is fired our of the mold in a gas furnace. Casting is done by the transferral of molten stainless steel from the crucible to the mold by centrifugal force in an electro-induction casting machine. Other mesh implants that have been developed are made from wire mesh, Dacron mesh, cast Ticonium, and hydroformed titanium.

  20. Do Clinical and Radiological Assessments Contribute to the Understanding of Biomaterials? Results From a Prospective Randomized Sinus Augmentation Split-Mouth Trial.

    PubMed

    Lorenz, Jonas; Korzinskas, Tadas; Chia, Poju; Maawi, Sarah Al; Eichler, Katrin; Sader, Robert A; Ghanaati, Shahram

    2018-02-01

    The present prospective randomized split-mouth trial reports on the 3-year clinical and radiological follow-up investigation of implants placed 7 months after sinus augmentation with 2 different bone substitute materials. The aim of the study was to complete the histologic observation of cellular reactions by analyses of the implants and the volumetric changes of the augmented bone substitute materials. A sinus augmentation split-mouth trial was performed in 14 patients with the synthetic bone substitute material Nanobone (NB) and the xenogeneic Bio-Oss (BO). Changes in volume and density of the augmented biomaterials were investigated by analysis of computed tomography scans, taken immediately after augmentation and after 7 months. Clinical implant parameters were assessed after 3 years of loading. Both bone substitute materials underwent nonsignificant volume reduction and significant increase in bone density over an integration period of 7 months. No significant differences concerning volume and bone density were observed between the groups. Three years after loading, 51 of 53 implants were in situ with no peri-implant infections, and only a few soft-tissue variations were present. The present prospective randomized study showed that no differences could be observed clinically and radiologically. Accordingly, it seems that both biomaterials, independent of their physicochemical composition, enable clinical success and long-time stability for dental implants. Interestingly, the histological results showed distinct differences in cellular reactions: While the xenogeneic BO induced a mild tissue reaction with only few multinucleated giant cells and comparably low vascularization, the synthetic NB induced a multinucleated giant cell-triggered tissue reaction with an increase of vascularization. Thus, the present study showed that a combination analysis-histological, clinical, and radiological-is necessary for a detailed assessment of a biomaterial's quality for

  1. Peritoneal dialysis catheter implantation by nephrologists is associated with higher rates of peritoneal dialysis utilization: a population-based study.

    PubMed

    Perl, Jeffrey; Pierratos, Andreas; Kandasamy, Gokulan; McCormick, Brendan B; Quinn, Robert R; Jain, Arsh K; Huang, Anjie; Paterson, J Michael; Oliver, Matthew J

    2015-02-01

    The likelihood of peritoneal dialysis (PD) utilization following a PD catheter insertion attempt is poorly described. We explored the risk factors for PD nonuse, focusing on the method of PD catheter implantation. This population-based retrospective cohort study employed Ontario administrative health data to identify 3886 predialysis adults who had an incident PD catheter implantation between 2002 and 2010. The impact of the method of catheter implantation including open-surgical (open, n = 1884), surgical-laparoscopic (laparoscopic, n = 1154), nephrology-percutaneous (nephrology, n = 498) and radiology-percutaneous (radiology, n = 350) on rates of PD utilization (defined as four consecutive weeks of PD) was examined. Eighty-three percent of study patients received PD. After adjustment, relative to patients with openly inserted catheters, PD utilization was greater for those with nephrology-inserted catheters [adjusted hazard ratio (aHR) 1.59, 95% confidence interval (CI) 1.29-1.95] and similar for radiology-inserted catheters [aHR 1.16, 95% CI 0.94-1.43] or laparoscopic-inserted catheters [aHR 0.97 (95% CI 0.86-1.09)]. Among PD nonusers, death occurred in 10% of the open group, 6% of the laparoscopic group, 27% of the radiology group and in fewer than 3% of the nephrology group. Sixty-nine percent received hemodialysis in the open group, 63% in the laparoscopic group, 61% in the radiology group and 88% in the nephrology group. Those remaining predialysis comprised 12% of the open group, 22% of the laparoscopic group, 11% of the radiology group and <3% of the nephrology group. Nephrology insertion resulted in lower overall rates of PD nonuse, particularly due to death or remaining predialysis. Greater use may be related to insertion timing, technique or greater commitment on the part of nephrologists to the success of PD. © The Author 2014. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  2. Central Vein Dilatation Prior to Concomitant Port Implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krombach, Gabriele A., E-mail: krombach@rad.rwth-aachen.de; Plumhans, Cedric; Goerg, Fabian

    2010-04-15

    Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker andmore » occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.« less

  3. Clinical, radiological and histological evaluation of biphasic calcium phosphate bioceramic wedges filling medial high tibial valgisation osteotomies.

    PubMed

    Rouvillain, J L; Lavallé, F; Pascal-Mousselard, H; Catonné, Y; Daculsi, G

    2009-10-01

    We report clinical, radiological and histological findings following high tibial valgisation osteotomy (HTVO) using micro-macroporous biphasic calcium phosphate wedges fixed with a plate and locking screws. From 1999 to 2002, 43 knees were operated on and studied prospectively. All underwent clinical and radiological follow-up at days 1, 90, and 365 to evaluate consolidation and bone substitute interfaces. Additionally, biopsies were taken for histology at least 1 year after implantation from 10 patients who requested plate removal. Radiologically, consolidation was observed in 98% of cases. At 1 year, correction was unchanged in 95% of cases. Histological analysis revealed considerable MBCP resorption and bone ingrowth, both into the pores and replacing the bioceramic material. Polarised light microscopy confirmed normal bony architecture with trabecular and/or dense lamellar bone growth at the expense of the wedge implants. X-ray and micro-CT scan revealed a well organised and mineralised structure in the newly-formed bone. This study shows that using MBCP wedges in combination with orientable locking screws and a plate is a simple, safe and fast surgical technique for HTVO. The is the first study to examine the results by histological analysis, which confirmed good outcomes.

  4. Immediate loading of subcrestally placed dental implants in anterior and premolar sites.

    PubMed

    Henningsen, Anders; Smeets, Ralf; Köppen, Kai; Sehner, Susanne; Kornmann, Frank; Gröbe, Alexander; Heiland, Max; Gerlach, Till

    2017-11-01

    Immediate loading of dental implants has been evolving into an appropriate procedure for the treatment of partially edentulous jaws. The purpose of this study was to evaluate the clinical success and radiological outcome of immediately and delayed loaded dental implants in anterior and premolar sites. In this retrospective study, data of 163 individuals requiring tooth removal with subsequent implant placement in anterior and premolar sites were analyzed. Implants were immediately loaded by provisional acrylic resin bridges or loaded with delay. Implants were followed up annually for up to 9 years including intraoral radiographs. A total of 285 implants in 163 patients were placed. 218 implants were immediately loaded and 67 implants with delay. Fifteen implants failed during the follow-up period resulting in survival rates of 94.5% for immediate loading and 95.5% for delayed loading. After an initial decrease of 0.3 mm in the first 12 months the marginal bone level remained stable. No statistically significant differences were found in marginal bone loss between immediately and delayed loaded implants (P = 0.518, 95% CI). Within the limits of this study, immediate loading of immediately subcrestally placed dental implants in anterior and premolar sites is a reliable treatment option for dental rehabilitation. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Nursing Home Use After Implantable Cardioverter-Defibrillator Implantation in Older Adults: Results from the National Cardiovascular Data Registry.

    PubMed

    Kramer, Daniel B; Reynolds, Matthew R; Normand, Sharon-Lise; Parzynski, Craig S; Spertus, John A; Mor, Vincent; Mitchell, Susan L

    2017-02-01

    To evaluate the incidence and characteristics of nursing home (NH) use after implantable cardioverter-defibrillator (ICD) implantation. Cohort study. Medicare beneficiaries in the National Cardiovascular Data Registry-ICD Registry. Individuals aged 65 and older receiving ICDs between January 1, 2006, and March 31, 2010 (N = 192,483). Proportion of ICD recipients discharged to NHs directly after device placement, cumulative incidence of long-term NH admission, and factors associated with immediate discharge to a NH and time to long-term NH admission. Over 4 years, 40.6% of the cohort died, and 35,939 (18.7%) experienced at least one NH admission, including 4.0% directly discharged to a NH after ICD implantation and 2.8% admitted to long-term NH care during follow-up. The cumulative incidence of long-term NH admission, accounting for the competing risk of death, was 1.7% at 1 year, 3.8% at 3 years, and 4.6% at 4 years; 20.1% of individuals admitted to a NH died there. Factors most strongly associated with direct NH discharge and time to long-term NH care were older age (adjusted odds ratio (AOR) = 2.09, 95% confidence interval (CI) = 2.01-2.17 per 10-year increment; adjusted hazard ratio (AHR) = 1.88, 95% CI = 1.80-1.97, respectively), dementia (AOR = 2.60, 95% CI = 2.25-3.01; AHR = 2.50, 95% CI = 2.14-2.93, respectively), and Medicare Part A claim for NH stay in prior 6 months (AOR = 3.96, 95% CI = 3.70-4.25; AHR = 2.88, 95% CI = 2.65-3.14, respectively). Nearly one in five individuals are admitted to NHs over a median of 1.6 years of follow-up after ICD implantation. Understanding these outcomes may help inform the clinical care of these individuals. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  6. Implant-supported single-tooth restorations. A 12-year prospective study.

    PubMed

    Donati, Mauro; Ekestubbe, Annika; Lindhe, Jan; Wennström, Jan L

    2016-10-01

    The aim of this study was to evaluate prospectively the 12-year outcome of implant-supported single-tooth restorations. Originally 45 self-tapping Astra Tech TiOblast ® ST-implants were installed by a two-stage protocol in 40 subjects requiring single-tooth prosthetic replacement for a missing tooth. Clinical and radiologic examinations were performed at completion of the prosthetic treatment 4-7 months after implant installation surgery and after 5 and 12 years in function. At 12 years 31 patients and 35 implants were available for evaluation. The overall failure rate after 12 years was 10.3% on the subject level and 9.1% on the implant level. The mean bone loss amounted to 0.67 mm (SD 2.20) on a subject level and 0.47 mm (1.72) on an implant level. Three subjects (10%) and three implants (8.6%) were diagnosed with peri-implantitis. Five subjects had experienced technical complications; three incidences of loosening of the abutment retention screw during the first 5 years and two minor porcelain fracture of the crown (two patients) between 5- and 12-years of follow-up. The findings reported in this 12-year prospective case series suggest that the use of the Astra Tech dental implants may be a valid treatment alternative for single-tooth replacement prostheses. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Complications and results of subdural grid electrode implantation in epilepsy surgery.

    PubMed

    Lee, W S; Lee, J K; Lee, S A; Kang, J K; Ko, T S

    2000-11-01

    We assessed the risk of delayed subdural hematoma and other complications associated with subdural grid implantation. Forty-nine patients underwent subdural grid implantation with/without subdural strips or depth electrodes from January 1994 to August 1998. To identify the risk associated with subdural grid implantation, a retrospective review of all patients' medical records and radiological studies was performed. The major complications of 50 subdural grid electrode implantations were as follows: four cases (7.8%) of delayed subdural hematoma at the site of the subdural grid, requiring emergency operation; two cases (3.9%) of infection; one case (2.0%) of epidural hematoma; and one case (2.0%) of brain swelling. After subdural hematoma removal, the electrodes were left in place. CCTV monitoring and cortical stimulation studies were continued thereafter. No delayed subdural hematoma has occurred since routine placement of subdural drains was begun. In our experience the worst complication of subdural grid implantation has been delayed subdural hematoma. Placement of subdural drains and close observation may be helpful to prevent this serious complication.

  8. A 10-year randomized clinical trial on the influence of splinted and unsplinted oral implants retaining mandibular overdentures: peri-implant outcome.

    PubMed

    Naert, Ignace; Alsaadi, Ghada; van Steenberghe, Daniel; Quirynen, Marc

    2004-01-01

    This randomized controlled clinical trial aimed to evaluate the efficacy of splinted implants versus unsplinted implants in overdenture therapy over a 10-year period. The study sample comprised 36 completely edentulous patients, 17 men and 19 women (mean age 63.7 years). In each patient, 2 implants (Brånemark System, Nobel Biocare, Göteborg, Sweden) were placed in the interforaminal area. Three to 5 months after placement, they were connected to standard abutments. The patients were then rehabilitated with ball-retained overdentures, magnet-retained overdentures, or bar-retained overdentures (the control group). Patients were followed for 4, 12, 60, and 120 months post-abutment connection. Group means as well as linear regression models were fitted with attachment type and time as classification variables and corrected for simultaneous testing (Tukey). After 10 years, 9 patients had died and 1 was severely ill. Over 10 years, no implants failed. Mean Plaque Index, Bleeding Index, change in attachment level, Periotest values, and marginal bone level at the end of the follow-up period were not significantly different among the groups. The annual marginal bone loss, excluding the first months of remodeling, was comparable with that found around healthy natural teeth. The fact that no implants failed and that overall marginal bone loss after the first year of bone remodeling was limited suggested that implants in a 2-implant mandibular overdenture concept have an excellent prognosis in this patient population, irrespective of the attachment system used.

  9. [When is an implant indicated? Need for a new approach].

    PubMed

    Grotowski, T

    The present popularity of implantology is partly due to the fact that it has now become fashionable, and this practice demands a new criterion of assessment. This can only be the clinical radiological one in which the choice of an implant must be made exclusively on the basis of a careful examination of the various existing situations within the field of implantology.

  10. Pediatric cochlear implants: additional disabilities prevalence, risk factors, and effect on language outcomes.

    PubMed

    Birman, Catherine S; Elliott, Elizabeth J; Gibson, William P R

    2012-10-01

    To determine the prevalence of additional disabilities in a pediatric cochlear population, to identify medical and radiologic conditions associated with additional disabilities, and to identify the effect of additional disabilities on speech perception and language at 12 months postoperatively. Retrospective case review. Tertiary referral center and cochlear implant program. Records were reviewed for children 0 to 16 years old inclusive, who had cochlear implant-related operations over a 12-month period. Diagnostic and rehabilitative. Additional disabilities prevalence; medical history and radiologic abnormalities; and the effect on Categories of Auditory Performance (CAP) score at 12 months postoperatively. Eighty-eight children having 96 operations were identified. The overall prevalence of additional disabilities (including developmental delay, cerebral palsy, visual impairment, autism and attention deficit disorder) was 33%. The main conditions associated with additional disabilities were syndromes and chromosomal abnormalities (87%), jaundice (86%), prematurity (62%), cytomegalovirus (60%), and inner ear abnormalities including cochlea nerve hypoplasia or aplasia (75%) and semicircular canal anomalies (56%). At 12 months postoperatively, almost all (96%) of the children without additional disabilities had a CAP score of 5 or greater (speech), compared with 52% of children with additional disabilities. Children with developmental delay had a median CAP score of 4, at 12 months compared with 6 for those without developmental delay. Additional disabilities are prevalent in approximately a third of pediatric cochlear implant patients. Additional disabilities significantly affect the outcomes of cochlear implants.

  11. Implantation techniques and chronic lead parameters of biventricular pacing dual-chamber defibrillators.

    PubMed

    Daoud, Emile G; Kalbfleisch, Steven J; Hummel, John D; Weiss, Raul; Augustini, Ralph S; Duff, Steven B; Polsinelli, Georgia; Castor, John; Meta, Tejas

    2002-10-01

    The aim of this study is to describe implantation techniques and lead performance for biventricular pacing, dual-chamber implantable cardioverter defibrillators (ICDs). A dual-chamber ICD with biventricular pacing was implanted in 87 patients with congestive heart failure (ejection fraction: 0.21 +/- 0.09), prolonged QRS duration (161 +/- 22 msec), and an indication for ICD therapy. Left ventricular pacing was achieved with a thoracotomy approach (n = 21) or a nonthoracotomy approach (n = 66). With a thoracotomy, biventricular devices were implanted successfully in all patients. During follow-up (17 +/- 11 months), 9 patients died (43%), 2 underwent transplantation, and 2 required left ventricular lead revision. At last follow-up, biventricular sensing and capture threshold were 11 +/- 5 mV and 1.5 +/- 0.8 V, respectively. For nonthoracotomy procedures, two types of coronary sinus (CS) leads were implanted: an over-the-wire lead (n = 45) and a shaped lead (n = 21). The rate of successful implantation (overall: 89%) (over-the-wire 93% vs shaped 81%; P = 0.1) and durations for CS lead placement (66 +/- 50 vs 58 +/- 34 min, P = 0.6) and the procedure (133 +/- 58 vs 129 +/- 33 min, P = 0.8) were not different between the two CS leads. During follow-up (11 +/- 9 months), 9 patients died (14%), and the shaped CS lead dislodged in 3 patients (3 shaped vs 0 over-the-wire, P = 0.01). At last follow-up, biventricular sensing and capture threshold were 10 +/- 4 mV and 1.8 +/- 0.7 V, respectively, and there was no difference between over-the-wire and shaped leads. By multivariate analysis, mortality was associated with absence of spironolactone therapy but not procedural features. Nonthoracotomy CS lead implantation is feasible, with a success rate of about 90% and few adverse events. For the remaining 10%, a thoracotomy approach can be completed safely in these ill patients without increased risk for death.

  12. Novel composite implant in craniofacial bone reconstruction.

    PubMed

    Peltola, Matti J; Vallittu, Pekka K; Vuorinen, Ville; Aho, Allan A J; Puntala, Antti; Aitasalo, Kalle M J

    2012-02-01

    Bioactive glass (BAG) and polymethyl methacrylate (PMMA) have been used in clinical applications. Antimicrobial BAG has the ability to attach chemically to surrounding bone, but it is not possible to bend, drill or shape BAG during the operation. PMMA has advantages in terms of shaping during the operation, but it does not attach chemically to the bone and is an exothermic material. To increase the usefulness of BAG and PMMA in skull bone defect reconstructions, a new composite implant containing BAG and PMMA in craniofacial reconstructions is presented. Three patients had pre-existing large defects in the calvarial and one in the midface area. An additive manufacturing (AM) model was used preoperatively for treatment planning and custom-made implant production. The trunk of the PMMA implant was coated with BAG granules. Clinical and radiological follow-up was performed postoperatively at 1 week, and 3, 6 and 12 months, and thereafter annually up to 5 years. Computer tomography (CT) and positron emission tomography (PET-CT) were performed at 12 and 24 months postoperatively. Uneventful clinical recovery with good esthetic and functional outcome was seen. CT and PET-CT findings supported good clinical outcome. The BAG-PMMA implant seems to be a promising craniofacial reconstruction alternative. However, more clinical experience is needed.

  13. Hearing rehabilitation with a binaural cochlear implant in a patient with Erdheim-Chester disease.

    PubMed

    Querat, Charlotte; Thai-Van, Hung; Durand, Denis Vital; Cotton, François; Gallego, Stéphane; Truy, Eric

    2015-09-01

    Erdheim-Chester disease (ECD) is a rare non-Langerhans form of histiocytosis. This paper reports an exceptional case of bilateral neural involvement, responsible for profound hearing loss. Bilateral cochlear implantation was performed. We present a 57-year-old man affected by ECD with profound bilateral hearing loss. The patient underwent cochlear implantation with a binaural Digisonic(®) cochlear implant, 7 years after the initial diagnosis. Speech intelligibility rose to a plateau after about 6 months of cochlear implant use. The average outcome of speech intelligibility over time was 55% for dissyllabic words without lip reading, and 70% for sentences. Perception score decreased before the patient died from ECD. A description of the ECD and its otological manifestations is presented. This paper reports the effective hearing rehabilitation of profound bilateral hearing loss by the means of a binaural Digisonic(®) cochlear implant.

  14. Partially Biodegradable Distraction Implant to Replace Conventional Implants in Alveolar Bone of Insufficient Height: A Preliminary Study in Dogs.

    PubMed

    Li, Tao; Zhang, Yongqiang; Shao, Bo; Gao, Yuan; Zhang, Chen; Cao, Qiang; Kong, Liang

    2015-12-01

    Dental implants have been widely used in the last few decades. However, patients with insufficient bone height need reconstructive surgeries before implant insertion. The distraction implant (DI) has been invented to simplify the treatment procedure, but the shortcomings of DIs have limited their clinical use. We incorporated biodegradable polyester into a novel DI called the partially biodegradable distraction implant (PBDI). The purpose of this study was to assess the radiological, histological, and biomechanical properties of the PBDI in animal models. PBDIs were manufactured and inserted into the atrophied mandibles of nine dogs. Box-shaped alveolar bones were segmented and distracted. The dogs were randomly divided into three groups that were sacrificed 1, 2, and 3 months after the implant insertion. Actual augmentation height (AAH) of the bone segments was measured to evaluate the effect of distraction. X-ray examination and micro-CT reconstruction and analysis were used to evaluate the regenerated bone in the distraction gap and bone around the functional element. Histological sections were used to evaluate the osseointegration and absorption of the PBDI. Fatigue tests were used to evaluate the biomechanical properties of the PBDI. Little change was found in AAH among the three groups. X-ray examination and micro-CT reconstruction showed good growth of regenerated bone in the distraction gap. Alveolar bone volume around the functional element increased steadily. No obvious bone absorption occurred in the alveolar crest around PBDI. Three months after distraction, the functional element achieved osseointegration, and the support element began to be absorbed. All PBDIs survived the fatigue test. The PBDI is a novel and reliable dental implant. It becomes a conventional implant after the absorption of the support element and the removal of the distraction screw. It is a promising replacement for conventional implants in patients with insufficient alveolar bone

  15. Embolization of a contraceptive implant into the pulmonary vasculature in an adolescent female.

    PubMed

    Gao, Gabriel T; Binder, William

    2018-06-01

    Nexplanon is a long-acting 4cm radio-opaque rod shaped contraceptive device implanted in the subdermal layer of the inner, upper arm. Complications from implantation are uncommon and mostly local and minor, including infection at the implantation site with resulting cellulitis or abscess, hematoma, abnormal scar formation, or local damage to nerves and blood vessels. Intravascular insertion is estimated to be at 1.3 per million Nexplanon implants, and migration and embolization is a rare complication of this device. We present a case report of a 16year old female who presented to the pediatric emergency department with subjective dyspnea and an embolized contraceptive device within a subsegmental branch of the left lower lobe pulmonary artery. After discussion with consultants, interventional radiology was able to successful retrieve the device without complication. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Predoctoral dental implant education at Creighton University School of Dentistry.

    PubMed

    Parrish, Lawrence; Hunter, Richard; Kimmes, Nici; Wilcox, Charles; Nunn, Martha; Miyamoto, Takanari

    2013-05-01

    The purpose of this report is to describe the dental implant education that predoctoral students receive and to characterize the patient population receiving implants at Creighton University School of Dentistry (CDS). CDS has no postdoctoral residency programs. Therefore, clinical management of diagnosis, treatment planning, surgical aspects, restoration, complications, and maintenance of dental implants requires significant involvement by predoctoral dental students. CDS implant education involves radiology diagnostic assets of the General Dentistry Department (including the use of Cone Beam Computed Tomography), as well as faculty and equipment from the Departments of Oral and Maxillofacial Surgery, Periodontics, and Prosthodontics, with a majority of students satisfied with their didactic preparation for their clinical experiences. Focusing on a three-year window from August 2007 to August 2010 and using electronic health records, this study found that a total of 242 implants were placed, out of which six failed within one year of placement and had to be removed. The average age of the population of 153 patients was found to be 53.3 years, with a range of eighteen to eighty-nine. Treatment outcomes compared very favorably with those published in the literature.

  17. Comparison of bioactive glass coated and hydroxyapatite coated titanium dental implants in the human jaw bone.

    PubMed

    Mistry, S; Kundu, D; Datta, S; Basu, D

    2011-03-01

    Current trends in clinical dental implant therapy include modification of titanium surfaces for the purpose of improving osseointegration by different additive (bioactive coatings) and subtractive processes (acid etching, grit-blasting). The aim of this study was to evaluate and compare the behaviour of hydroxyapatite and the newly developed bioactive glass coated implants (62 implants) in osseous tissue following implantation in 31 patients. Bioactive glass and hydroxyapatite was suitably coated on titanium alloy. Hydroxyapatite coating was applied on the implant surface by air microplasma spray technique and bioactive glass coating was applied by vitreous enamelling technique. The outcome was assessed up to 12 months after prosthetic loading using different clinical and radiological parameters. Hydroxyapatite and bioactive glass coating materials were non-toxic and biocompatible. Overall results showed that bioactive glass coated implants were as equally successful as hydroxyapatite in achieving osseointegration and supporting final restorations. The newly developed bioactive glass is a good alternative coating material for dental implants. © 2011 Australian Dental Association.

  18. Esthetic evaluation of single-tooth implants in the anterior maxilla following autologous bone augmentation.

    PubMed

    Hof, M; Pommer, B; Strbac, G D; Sütö, D; Watzek, G; Zechner, W

    2013-08-01

    Autologous bone augmentation to rebuild compromised alveolar ridge contour prior to implant placement allows for favorable three-dimensional implant positioning to achieve optimum implant esthetics. The aim of the present study was to evaluate peri-implant soft tissue conditions around single-tooth implants following bone grafts in the esthetic zone of the maxilla. Sixty patients underwent autologous bone augmentation of deficient maxillary sites prior to placement of 85 implants in the esthetic zone. In case of multiple implants per patient, one implant was randomly selected. Objective evaluation of 60 single-tooth implants was performed using the Pink-Esthetic-Score (PES) and Papilla Index (PI) and supplemented by subjective patient evaluation, as well as clinical and radiologic examination. Objective ratings of implant esthetics were satisfactory (median PES: 11, median PI: 2) and significantly correlated with high patient satisfaction (mean VAS score: 80%). Both esthetic indices demonstrated respectable levels of inter- as well as intra-observer agreement. Poor implant esthetics (low PES and PI ratings) were significantly associated with increased anatomic crown height, while no influence of horizontal implant-tooth distance could be found. The present investigation indicates that favorable esthetic results may be achieved in the augmented anterior maxilla. However, bony reconstruction of compromised alveolar ridges does not guarantee optimum implant esthetics. © 2011 John Wiley & Sons A/S.

  19. Marginal Bone Loss Around Early-Loaded SLA and SLActive Implants: Radiological Follow-Up Evaluation Up to 6.5 Years.

    PubMed

    Şener-Yamaner, Işil Damla; Yamaner, Gökhan; Sertgöz, Atilla; Çanakçi, Cenk Fatih; Özcan, Mutlu

    2017-08-01

    The aim of this study was to compare marginal bone loss around early-loaded SLA and SLActive tissue-level implants (Straumann Dental Implants; Institut Straumann AG, Basel, Switzerland) after a mean of 81-month follow-up period. One hundred seven SLA and 68 SLActive implants were placed in 55 patients and loaded with final restoration after 8 and 3 weeks of healing time, respectively. Marginal bone loss around implants was determined radiographically at initial and after a mean observation time ranging between 20 and 81 months. The effect of location (mandible vs maxilla), smoking habit, sex, implant length and diameter, and the type of prosthesis on the marginal bone loss was evaluated. The overall cumulative survival rate was 98.2% being 99% for SLA implants and 97% for SLActive implants. After 20-month follow-up period, mean marginal bone loss values for the SLA and SLActive implants were 0.24 and 0.17 mm, respectively. After 81 months, mean marginal bone loss for the SLA and SLActive implants reached 0.71 and 0.53 mm, respectively. Marginal bone loss was affected by the length and type of implant and patients' smoking habit after a mean observation time of 20 months. However, none of the parameters had any significant effect on the marginal bone loss after a follow-up period of 81 months. With both SLA and SLActive implants, successful clinical results could be achieved up to 6.5 years of follow-up period.

  20. Nine-year outcome after anatomic stemless shoulder prosthesis: clinical and radiologic results.

    PubMed

    Hawi, Nael; Magosch, Petra; Tauber, Mark; Lichtenberg, Sven; Habermeyer, Peter

    2017-09-01

    Several stemless shoulder implants are available on the market, but only a few studies have presented results with sufficient mid- to long-term follow-up. The present study evaluated clinical and radiologic outcomes 9 years after anatomic stemless shoulder replacement. This is a prospective cohort study evaluating the stemless shoulder prosthesis since 2005. Anatomic stemless shoulder replacement using a single prosthesis was performed in 49 shoulders; 17 underwent total shoulder replacement, and 32 underwent hemiarthroplasty. Forty-three patients were clinically and radiologically monitored after a mean of 9 years (range, 90-127 months; follow-up rate, 88%). The indications for shoulder replacement were primary osteoarthritis in 7 shoulders, post-traumatic in 24, instability in 7, cuff tear arthropathy in 2, postinfectious arthritis in 1, and revision arthroplasty in 2. The Constant-Murley Score improved significantly from 52% to 79% (P < .0001). The active range of motion also increased significantly for flexion from 101° to 118° (P = .022), for abduction from 79° to 105° (P = .02), and for external rotation from 21° to 43° (P < .0001). Radiologic evaluation revealed incomplete radiolucency in 1 patient without clinical significance or further intervention. No revision caused by loosening or countersinking of the humeral implant was observed. The 9-year outcome after stemless shoulder replacement is comparable to that of third- and fourth-generation standard shoulder arthroplasty. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Placement of central venous port catheters and peripherally inserted central catheters in the routine clinical setting of a radiology department: analysis of costs and intervention duration learning curve.

    PubMed

    Rotzinger, Roman; Gebauer, Bernhard; Schnapauff, Dirk; Streitparth, Florian; Wieners, Gero; Grieser, Christian; Freyhardt, Patrick; Hamm, Bernd; Maurer, Martin H

    2017-12-01

    Background Placement of central venous port catheters (CVPS) and peripherally inserted central catheters (PICC) is an integral component of state-of-the-art patient care. In the era of increasing cost awareness, it is desirable to have more information to comprehensively assess both procedures. Purpose To perform a retrospective analysis of interventional radiologic implantation of CVPS and PICC lines in a large patient population including a cost analysis of both methods as well as an investigation the learning curve in terms of the interventions' durations. Material and Methods All CVPS and PICC line related interventions performed in an interventional radiology department during a three-year period from January 2011 to December 2013 were examined. Documented patient data included sex, venous access site, and indication for CVPS or PICC placement. A cost analysis including intervention times was performed based on the prorated costs of equipment use, staff costs, and expenditures for disposables. The decrease in intervention duration in the course of time conformed to the learning curve. Results In total, 2987 interventions were performed by 16 radiologists: 1777 CVPS and 791 PICC lines. An average implantation took 22.5 ± 0.6 min (CVPS) and 10.1 ± 0.9 min (PICC lines). For CVPS, this average time was achieved by seven radiologists newly learning the procedures after performing 20 CVPS implantations. Total costs per implantation were €242 (CVPS) and €201 (PICC lines). Conclusion Interventional radiologic implantations of CVPS and PICC lines are well-established procedures, easy to learn by residents, and can be implanted at low costs.

  2. Two-generation reproductive toxicity study of implanted depleted uranium (DU) in CD rats.

    PubMed

    Arfsten, D P; Still, K R; Wilfong, E R; Johnson, E W; McInturf, S M; Eggers, J S; Schaeffer, D J; Bekkedal, M Y-V

    2009-01-01

    Depleted uranium (DU) munitions and armor plating have been used in several conflicts over the last 17 yr, including the Persian Gulf War and the Iraq War. Because of its effectiveness and availability, DU will continue to be used in military applications into the foreseeable future. There is much controversy over the use of DU in weapons and equipment because of its potential radiological and toxic hazards, and there is concern over the chronic adverse health effects of embedded DU shrapnel in war veterans and bystanders. This study evaluated the effects of long-term implantation of DU on the reproductive success of F0 generation adults and development and survival of subsequent F1 and F2 generations in a two-generation reproductive toxicity study. F0 generation Sprague-Dawley rats, 8 wk of age, were surgically implanted with 0, 4, 8, 12, or 20 DU pellets (1 x 2 mm). Inert implant control animals were implanted with 12 or 20 tantallum (Ta) pellets. The F0 generation was then mated at 120 d post DU implantation. In the F0 generation, when measured on postimplantation d 27 and 117, uranium was present in the urine of DU-implanted animals in a dose-dependent manner. F0 reproductive success was similar across treatment groups and the maternal retrieval test revealed no changes in maternal behavior. DU implantation exerted no effect on the survival, health, or well-being of the F0 generation. Necropsy results of F0 animals were negative with the exception of a marked inflammatory response surrounding the implanted DU pellets. For the F1 generation, measures of F1 development through postnatal day (PND) 20 were unremarkable and no gross abnormalities were observed in F1 offspring. No uranium was detected in whole-body homogenates of PND 4 or PND 20 pups. Necropsy findings of F1 PND 20 pups were negative and no instances of ribcage malformation were observed in F1 PND 20 pups. Body weight and body weight gain of F1 rats through PND 120 were similar across treatment

  3. Trans-apical aortic valve implantation using a new self-expandable bioprosthesis: initial outcomes.

    PubMed

    Kempfert, Jörg; Rastan, Ardawan J; Beyersdorf, Friedhelm; Schönburg, Markus; Schuler, Gerhard; Sorg, Stefan; Mohr, Friedrich-W; Walther, Thomas

    2011-11-01

    Trans-apical aortic valve implantation (TA-AVI) has evolved into a standard approach for high-risk, elderly patients using the balloon-expandable Edwards SAPIEN™ prosthesis. As an alternative device, a self-expanding sub-coronary trans-apical bioprosthesis was evaluated. The Symetis Acurate™ trans-catheter heart valve is composed of a porcine biologic valve attached to a self-expandable nitinol stent. It allows for anatomical orientation, and facilitates intuitive implantation providing tactile feedback. Three valves sizes were available to treat patients with an annular diameter between 21 and 27mm. Since November 2009, a total of 40 patients have been treated at three sites. Patient age was 82.8±4 years, 60% were female, logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 21.5±10.9% and Society of Thoracic Surgeons (STS) Score was 9.0±4.6%. All implants were delivered successfully in the intra-annular and sub-coronary position off pump. One patient was converted to conventional surgery due to coronary impingement; post-dilatation was performed in 45% of patients; and two patients required the SAPIEN™ valve in valve implantation. Echocardiographic and angiographic control revealed no/trivial aortic incompetence (AI) in 59%, mild AI in 33.3%, and moderate AI in 7.7% of the patients. Three patients died within 30 days from a non-valve-related cause (respiratory), the patient converted did not recover from right-heart failure, and one patient died on day 19 due to unclear reasons. There was one incidence of new-onset atrioventricular (AV) block requiring pacemaker implantation. Two patients suffered a stroke (one secondary and the other intraprocedural). Transvalvular gradients were maximum 29.4±10.7mmHg and mean 14.3±6.8mmHg. The initial clinical results indicate a relatively straightforward implantation procedure and good functional results after trans-apical implantation of the Symetis Acurate™ device. Copyright © 2011

  4. Stratification of risk to the surgical team in removal of small arms ammunition implanted in the craniofacial region: case report.

    PubMed

    Forbes, Jonathan A; Laughlin, Ian; Newberry, Shane; Ryhn, Michael; Pasley, Jason; Newberry, Travis

    2016-09-01

    In cases of penetrating injury with implantation of small arms ammunition, it can often be difficult to tell the difference between simple ballistics and ballistics associated with unexploded ordnances (UXOs). In the operative environment, where highly flammable substances are often close to the surgical site, detonation of UXOs could have catastrophic consequences for both the patient and surgical team. There is a paucity of information in the literature regarding how to evaluate whether an implanted munition contains explosive material. This report describes a patient who presented during Operation Enduring Freedom with an implanted munition suspicious for a UXO and the subsequent workup organized by Explosive Ordnance Disposal (EOD) Company prior to surgical removal. Clinical risk factors for UXOs include assassination attempts and/or wartime settings. Specific radiological features suggestive of a UXO include projectile size greater than 7.62-mm caliber, alterations in density of the tip, as well as radiological evidence of a hollowed-out core. If an implanted UXO is suspected, risks to the surgical and anesthesia teams can be minimized by notifying the nearest military installation with EOD capabilities and following clinical practice guidelines set forth by the Joint Theater Trauma System.

  5. Packaged die heater

    DOEpatents

    Spielberger, Richard; Ohme, Bruce Walker; Jensen, Ronald J.

    2011-06-21

    A heater for heating packaged die for burn-in and heat testing is described. The heater may be a ceramic-type heater with a metal filament. The heater may be incorporated into the integrated circuit package as an additional ceramic layer of the package, or may be an external heater placed in contact with the package to heat the die. Many different types of integrated circuit packages may be accommodated. The method provides increased energy efficiency for heating the die while reducing temperature stresses on testing equipment. The method allows the use of multiple heaters to heat die to different temperatures. Faulty die may be heated to weaken die attach material to facilitate removal of the die. The heater filament or a separate temperature thermistor located in the package may be used to accurately measure die temperature.

  6. Reverse shoulder arthroplasty with a cementless short metaphyseal humeral implant without a stem: clinical and radiologic outcomes in prospective 2- to 7-year follow-up study.

    PubMed

    Levy, Ofer; Narvani, Ali; Hous, Nir; Abraham, Ruben; Relwani, Jai; Pradhan, Riten; Bruguera, Juan; Sforza, Giuseppe; Atoun, Ehud

    2016-08-01

    Reverse shoulder prostheses are increasingly used in recent years for treatment of glenohumeral arthropathy with deficient rotator cuff. Bone preservation is becoming a major goal in shoulder replacement surgery. Metaphyseal humeral components without a stem were developed to minimize bone resection and preserve bone. This study evaluated the clinical and radiologic outcomes at 2 to 7 years using a novel short metaphyseal reverse total shoulder arthroplasty (rTSA) prosthesis without a diaphyseal stem. Between 2005 and 2010, 102 consecutive patients underwent rTSA with this implant, and 98 (20 men, 78 women) were available for follow-up. Mean age was 74.4 years (range, 38-93 years). Indications were cuff tear arthropathy, 65; fracture sequelae, 12; rheumatoid arthritis, 13; failed rotator cuff repair, 3; cuff deficiency with loosening of anatomic prosthesis, 3; and acute trauma, 2; with 17 of these as revisions. Patients' satisfaction (Subjective Shoulder Value) improved from 8 of 100 to 85 of 100. The Constant score improved from 14 to 59 (age- and sex-adjusted, 86; P < .0001). Range of motion improved from 47° to 129° in elevation, 10° to 51° in external rotation, and 21° to 65° in internal rotation. Radiographic analysis showed no lucencies, subsidence, or stress shielding around the humeral or glenoid components. Glenoid notching was found in 21 patients (18 grade 1-2; 3 grade 3). The short metaphyseal rTSA design without a diaphyseal stem shows encouraging short- to midterm results, with excellent pain relief and shoulder function, restoration of good active range of motion, and high patient satisfaction scores. The design of this implant seems to result in improved rotational movements, low incidence of glenoid notching, and no implant loosening, subsidence, or stress shielding. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. Radioactive implant migration in patients treated for localized prostate cancer with interstitial brachytherapy.

    PubMed

    Older, R A; Synder, B; Krupski, T L; Glembocki, D J; Gillenwater, J Y

    2001-05-01

    In several of the initial patients undergoing brachytherapy at our institution radioactive implants were visible in the thorax on chest radiography. The clinical ramifications of this unanticipated finding were unclear. Thus, we investigated the incidence of brachytherapy seed migration to the chest and whether these seeds were associated with any clinical significance. We retrospectively reviewed the records of all patients who underwent ultrasound or computerized tomography guided brachytherapy of 103palladium seeds from March 1997 to March 1999. This list of patients on brachytherapy was then matched against the radiology computer system to determine those who had undergone chest X-ray after brachytherapy. When the radiology report was unclear regarding brachytherapy seeds, chest x-rays were reviewed by one of us (R. O.) to determine the presence and position of the seeds. Post-brachytherapy chest x-rays were available in 110 of the 183 patients. In 78 cases no brachytherapy seeds were identified. Radioactive implants were identified on chest radiography in 32 patients (29%), including 1 to 5 seeds in 20, 8, 1, 2 and 1, respectively. No patients complained of any change in pulmonary symptoms after brachytherapy. Radioactive implants migrated after brachytherapy for localized prostate cancer in 29% of the patients who underwent post-procedure radiography. There did not appear to be a pattern to the seed distribution. However, while the incidence was not negligible, no patient appeared to have any acute pulmonary symptoms. Therefore, while the migration of radioactive implants to the chest is a real phenomenon, it appears to have no adverse clinical consequences in the early post-procedure period.

  8. Clinical and radiological investigations of mandibular overdentures supported by conventional or mini-dental implants: A 2-year prospective follow-up study.

    PubMed

    Temizel, Sonay; Heinemann, Friedhelm; Dirk, Cornelius; Bourauel, Christoph; Hasan, Istabrak

    2017-02-01

    Conventional dental implants are not applicable in the mandibular interforaminal region if bone volume is limited. Mini-dental implants offer an alternative means of supporting mandibular overdentures in a narrow residual ridge, without additional surgery. The purpose of this nonrandomized clinical trial was to compare the ability of mini-dental implants with that of conventional dental implants in supporting mandibular overdentures during a 2-year clinical follow-up. Bone quality, bone resorption, implant stability, and oral health were assessed radiographically. A total of 32 participants with edentulism were included. Twenty-two participants (99 implants) received 4 to 5 mini-dental implants (diameter: 1.8-2.4 mm; length: 13-15 mm, study group), and 10 participants (35 implants) received 2 to 4 conventional dental implants (diameter: 3.3-3.7 mm; length: 11-13 mm, control group). The selection of the participants in the study or control group was based on the available bone volume in the mandible. The selection was not randomized. The density of cortical bone thickness was measured in Hounsfield units (HU) from computed tomography data, and patients were followed for 2 years. The participants were examined 3, 6, 12, and 24 months after surgery. Primary stability immediately after the insertion of dental implants (Periotest), secondary stability 6 months after implantation, modified plaque, bleeding on probing indices, and probing depth were measured and analyzed statistically (α=.05). The mean HU value 6 months after implantation in the participants who received mini-dental implants was significantly (P=.035) higher (1250 HU) than that in the participants who received conventional dental implants (1100 HU). The probing depths around the conventional dental implants (1.6 and 1.8 mm, respectively) were significantly higher than those around the mini-dental implants (1.3 and 1.2 mm, respectively) 12 and 24 months after surgery, respectively (P<.001). The mean

  9. Orthopedic implant devices: prevalence and sociodemographic findings from the 1988 National Health Interview Survey.

    PubMed

    Moore, R M; Hamburger, S; Jeng, L L; Hamilton, P M

    1991-01-01

    National population-based estimates on the magnitude and distribution of orthopedic implant devices in the United States have not been available to date. The Food and Drug Administration's Center for Devices and Radiological Health (FDA/CDRH) collaborated with the Centers for Disease Control's National Center for Health Statistics (CDC/NCHS) in the design and conduct of a nationwide medical device implant survey to generate the first national population-based prevalence estimates of orthopedic implant devices. A Medical Device Implant Supplement to the 1988 National Health Interview Survey was administered in personal household interviews to a national sample of 47,485 households, which included 122,310 individuals. An estimated 6.5 million orthopedic implants were in use in the general US population in 1988, including 1.6 million artificial joints and 4.9 million fixation devices. As a group, orthopedic implants comprised nearly half of all medical device implants in use, 43.4%. The majority of artificial joint recipients were 65 years of age or older, white, and male. The majority of fixation device recipients were less than 45 years of age, white, and male. The limitations and strengths of these population-based estimates are discussed.

  10. Infrequent physician use of implantable cardioverter-defibrillators risks patient safety.

    PubMed

    Lyman, Stephen; Sedrakyan, Art; Do, Huong; Razzano, Renee; Mushlin, Alvin I

    2011-10-01

    Implantable cardioverter-defibrillators (ICDs) have diffused rapidly into clinical practice with little evaluation of their real-world effectiveness. To determine the effect of the adoption of ICD on patient safety, particularly with respect to physician volume and early outcomes. Retrospective cohort of all ICD implantations in New York state from 1997 to 2006, with follow-up at 90 days and 1 year. Setting New York state non-federal hospital discharges in which an ICD was implanted during the admission. Patients were followed forward for 1 year for subsequent admissions. Patients New York state residents undergoing ICD implantation. Effects of annual and career ICD implantation volume on 90-day complication, readmission, reprogramming, mortality and revision of the ICD within 1 year. This cohort (N = 38,992) represents a period of rapid adoption and implementation of this new technology, with frequency more than tripling between 1997 and 2006. We identified 6439 (16.5%) post-implantation complications and 1093 (2.8%) deaths within 90 days of implantation. The majority (73.4%) of physicians implanted one or fewer ICDs per year, and 11.0% of all implantations were performed by these very-low-volume operators. Patients treated by very-low-volume operators were more likely to die (RR = 1.8, 95% CI 1.3 to 2.4) or experience cardiac complications (RR = 4.7, 95% CI 3.3 to 6.8) even after the adjustment for case mix compared to operators who frequently performed ICD implantation. These findings suggest a need for safe and effective implementation strategies for new medical technologies, which minimize patient risk due to rapid diffusion among inexperienced providers and assure that the intended benefit can be maximised rapidly.

  11. Scala vestibuli cochlear implantation in patients with partially ossified cochleas.

    PubMed

    Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari

    2002-11-01

    Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.

  12. Subcutaneous Implants of Buprenorphine-Cholesterol-Triglyceride Powder in Mice.

    PubMed

    DeTolla, L; Sanchez, R; Khan, E; Tyler, B; Guarnieri, M

    2014-01-01

    Subcutaneous drug implants are convenient systems for the long-term delivery of drugs in animals. Lipid carriers are logical tools because they generally allow for higher doses and low toxicity. The present study used an US Food and Drug Administration Target Animal Safety test system to evaluate the safety of a subcutaneous implant of a cholesterol-triglyceride-buprenorphine powder in 120 BALB/c mice. Mice were evaluated in 4- and 12-day trials with 1- and 5-fold doses of the intended 3 mg/kg dose of drug. One male mouse treated with three 3 mg/kg doses and surgery on days 0, 4, and 8 died on day 9. The cause of death was not determined. In the surviving 119 mice there was no evidence of skin reaction at the site of the implant. Compared to control animals treated with saline, weight measurements, clinical pathology, histopathology, and clinical observations were unremarkable. These results demonstrate that the lipid carrier is substantially safe. Cholesterol-triglyceride-drug powders may provide a valuable research tool for studies of analgesic and inflammatory drug implants in veterinary medicine.

  13. Subcutaneous Implants of Buprenorphine-Cholesterol-Triglyceride Powder in Mice

    PubMed Central

    DeTolla, L.; Sanchez, R.; Khan, E.; Tyler, B.; Guarnieri, M.

    2014-01-01

    Subcutaneous drug implants are convenient systems for the long-term delivery of drugs in animals. Lipid carriers are logical tools because they generally allow for higher doses and low toxicity. The present study used an US Food and Drug Administration Target Animal Safety test system to evaluate the safety of a subcutaneous implant of a cholesterol-triglyceride-buprenorphine powder in 120 BALB/c mice. Mice were evaluated in 4- and 12-day trials with 1- and 5-fold doses of the intended 3 mg/kg dose of drug. One male mouse treated with three 3 mg/kg doses and surgery on days 0, 4, and 8 died on day 9. The cause of death was not determined. In the surviving 119 mice there was no evidence of skin reaction at the site of the implant. Compared to control animals treated with saline, weight measurements, clinical pathology, histopathology, and clinical observations were unremarkable. These results demonstrate that the lipid carrier is substantially safe. Cholesterol-triglyceride-drug powders may provide a valuable research tool for studies of analgesic and inflammatory drug implants in veterinary medicine. PMID:26464927

  14. SPHERICAL DIE

    DOEpatents

    Livingston, J.P.

    1959-01-27

    A die is presented for pressing powdered materials into a hemispherical shape of uniforin density and wall thickness comprising a fcmale and male die element held in a stationary spaced relation with the space being equivalent to the wall thickness and defining the hemispherical shape, a pressing ring linearly moveable along the male die element, an inlet to fill the space with powdered materials, a guiding system for moving the pressing ring along the male die element so as to press the powdered material and a heating system for heating the male element so that the powdered material is heated while being pressed.

  15. 10-year survival rate and the incidence of peri-implant disease of 374 titanium dental implants with a SLA surface: a prospective cohort study in 177 fully and partially edentulous patients.

    PubMed

    van Velzen, Frank J J; Ofec, Ronen; Schulten, Engelbert A J M; Ten Bruggenkate, Christiaan M

    2015-10-01

    This prospective cohort study evaluates the 10-year survival and incidence of peri-implant disease at implant and patient level of sandblasted, large grid, and acid-etched titanium dental implants (Straumann, soft tissue level, SLA surface) in fully and partially edentulous patients. Patients who had dental implant surgery in the period between November 1997 and June 2001, with a follow-up of at least 10 years, were investigated for clinical and radiological examination. Among the 506 inserted dental implants in 250 patients, 10-year data regarding the outcome of implants were available for 374 dental implants in 177 patients. In the current study, peri-implantitis was defined as advanced bone loss (≧1.5 mm. postloading) in combination with bleeding on probing. At 10-year follow-up, only one implant was lost (0.3%) 2 months after implant surgery due to insufficient osseointegration. The average bone loss at 10 year postloading was 0.52 mm. Advanced bone loss at 10-year follow-up was present in 35 dental implants (9.8%). Seven percent of the observed dental implants showed bleeding on probing in combination with advanced bone loss and 4.2% when setting the threshold for advanced bone loss at 2.0 mm. Advanced bone loss without bleeding on probing was present in 2.8% of all implants. In this prospective study, the 10-year survival rate at implant and patient level was 99.7% and 99.4%, respectively. Peri-implantitis was present in 7% of the observed dental implants according to the above-mentioned definition of peri-implantitis. This study shows that SLA implants offer predictable long-term results as support in the treatment of fully and partially edentulous patients. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Die Soldering in Aluminium Die Casting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, Q.; Kenik, E.A.; Viswanathan, S.

    2000-03-15

    Two types of tests, dipping tests and dip-coating tests were carried out on small steel cylinders using pure aluminum and 380 alloy to investigate the mechanism of die soldering during aluminum die casting. Optical and scanning electron microscopy were used to study the morphology and composition of the phases formed during soldering. A soldering mechanism is postulated based on experimental observations. A soldering critical temperature is postulated at which iron begins to react with aluminum to form an aluminum-rich liquid phase and solid intermetallic compounds. When the temperature at the die surface is higher than this critical temperature, the aluminum-richmore » phase is liquid and joins the die with the casting during the subsequent solidification. The paper discusses the mechanism of soldering for the case of pure aluminum and 380 alloy casting in a steel mold, the factors that promote soldering, and the strength of the bond formed when soldering occurs. conditions, an aluminum-rich soldering layer may also form over the intermetallic layer. Although a significant amount of research has been conducted on the nature of these intermetallics, little is known about the conditions under which soldering occurs.« less

  17. Marginal bone level changes in association with different vertical implant positions: a 3-year retrospective study

    PubMed Central

    2017-01-01

    Purpose To retrospectively evaluate the relationship between the vertical position of the implant-abutment interface and marginal bone loss over 3 years using radiological analysis. Methods In total, 286 implant surfaces of 143 implants from 61 patients were analyzed. Panoramic radiographic images were taken immediately after implant installation and at 6, 12, and 36 months after loading. The implants were classified into 3 groups based on the vertical position of the implant-abutment interface: group A (above bone level), group B (at bone level), and group C (below bone level). The radiographs were analyzed by a single examiner. Results Changes in marginal bone levels of 0.99±1.45, 1.13±0.91, and 1.76±0.78 mm were observed at 36 months after loading in groups A, B, and C, respectively, and bone loss was significantly greater in group C than in groups A and B. Conclusions The vertical position of the implant-abutment interface may affect marginal bone level change. Marginal bone loss was significantly greater in cases where the implant-abutment interface was positioned below the marginal bone. Further long-term study is required to validate our results. PMID:28861287

  18. DR AVRAM JOZEF VINAVER (1862-1915) - PIONEER OF RADIOLOGY IN SERBIA.

    PubMed

    Babić, Rade Radomir; Stanković Babić, Gordana

    2015-01-01

    Dr Abraham Joseph Vinaver (1862-1915), a Jew from Poland, was a pioneer of radiology in Serbia. He graduated from the Faculty of Medicine in Warsaw (1887), but lived and worked in abac (the Kingdom of Serbia) since 1890. Dr Abraham Joseph Vinarev - Career Development. He procured the first X-ray machine and developed radiological service in Sabac five years after the discovery of X-rays. These were the beginnings of radiology in Serbia. He introduced the application of artesian wells. Dr Abraham Joseph Vinarev - a Participant at the First Congress of Serbian Physicians and Naturalists, Belgrade 1904. "The diagnostic importance of X-rays in lung disease, especially in initial tuberculosis" and "Five Years of Treatment by X-Ray Machines" were the first works in the field of radiology in Serbia by this author. Dr Abraham Joseph Vinaver - Reserve Medical Officer in the Serbian Army. During the Balkan Wars, he was a volunteer with the rank of major engaged in military corps and he participated in the First World War as well. He died of malaria in 1915 in Gevgelija. "Dr Avram Vinaver"- Stanislav Vinarev. His dedication to work during the typhus epidemics was put into verses of a poem by his son Stanislav Vinarev. Dr Avram Vinaver Joseph was a noble man with a great heart, who selflessly sacrificed himself for the Serbian people and Serbia. He gave his contribution to the development of health services in Serbia, both in peacetime and wartime conditions. Dr Abraham Joseph Vinaver laid the foundations for today's radiology in Serbia.

  19. A Survey of the Opinion and Experience of UK Dentists: Part 1: The Incidence and Cause of Iatrogenic Trigeminal Nerve Injuries Related to Dental Implant Surgery.

    PubMed

    Yilmaz, Zehra; Ucer, Cemal; Scher, Edwin; Suzuki, Jon; Renton, Tara

    2016-10-01

    Dental implant-related iatrogenic trigeminal nerve (TG) injuries are proportionally increasing with dental implant surgery. This study, which is presented in greater detail over a series of articles, assessed the experience of implant-related TG nerve injuries among UK dentists. Incidence and cause of inferior alveolar nerve (IAN), mental nerve (MN), and lingual nerve (LN) injuries, together with preoperative assessment and the consent process, are presented in this article. A survey was distributed among 405 dentists attending an Association of Dental Implantology congress in the United Kingdom, of which 187 completed the survey. Most responding dentists were full-time general practitioners. Implant dentistry training was predominately through industry-organized courses. Eighty dentists encountered implant-related IAN injuries, whereas 8 encountered LN injuries. Inaccurate radiological identification of the IAN/MN and their anatomical variations (48%) were seen to be the most frequent cause of TG injuries. Disclosure of the relative risk and benefits of alternative implant treatment strategies as part of the informed consent process was not deemed to be essential by 47 (25%) of the participants. Inadequate radiological assessment was the most common cause of TG nerve injury. The use of small field of view cone beam computer tomography (CBCT) is therefore recommended when placing implants in the posterior mandible. Implant surgeons should acquire evidence-based skills in the prevention, diagnosis, and management of TG nerve injury as well as specific training on justification and interpretation of CBCT scans.

  20. Esthetic evaluation of single-tooth implants in the anterior mandible.

    PubMed

    Hof, Markus; Tepper, Gabor; Koller, Barbara; Krainhöfner, Martin; Watzek, Georg; Pommer, Bernhard

    2014-09-01

    Single-tooth replacement of anterior mandibular teeth is frequently complicated by insufficient bucco-lingual bone width and limited mesio-distal space available for implant placement. The aim of the present study was to assess implant esthetics in the partially edentulous anterior mandible. Esthetic evaluation of 43 anterior mandibular single-tooth implants in 15 women and 28 men was performed using esthetic indices (PES = Pink Esthetic Score, PI = Papilla Index, SES = Subjective Esthetic Score) as well as subjective patients' Visual Analogue Scale (VAS) ratings. Clinical and radiological parameters (implant and crown dimensions, pocket depth, bleeding on probing, plaque, keratinized mucosa, marginal bone level, and distance to adjacent teeth) were tested for influence. Implant esthetics were judged satisfactory (PES ≤10) in 42% of implants compared with a patient satisfaction rate of 87%. Correlation between objective indices (PES/PI: rs  = 0.62, PES/SES: rs  = -0.73, PI/SES: rs  = -0.48) was highly significant (P ≤ 0.001); however, no association to subjective patients' ratings could be observed. Type of prosthetic restoration (single crown vs. tulip-shaped double crowns), mesio-distal crown width as well as anatomic crown length significantly affected esthetic scores. Patients' judgment, by contrast, could not be associated to any prognostic factor. Subjective patient satisfaction with implant esthetics in the partially edentulous anterior mandible is high, however, remains hard to predict or objectively quantify. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. HIGH PRESSURE DIES

    DOEpatents

    Wilson, W.B.

    1960-05-31

    A press was invented for subjecting specimens of bismuth, urania, yttria, or thoria to high pressures and temperatures. The press comprises die parts enclosing a space in which is placed an electric heater thermally insulated from the die parts so as not to damage them by heat. The die parts comprise two opposed inner frustoconical parts and an outer part having a double frustoconical recess receiving the inner parts. The die space decreases in size as the inner die parts move toward one another against the outer part and the inner parts, though very hard, do not fracture because of the mode of support provided by the outer part.

  2. Comparison of Results of Measurement of Dimensions of the Placed Dental Implants on Cone Beam Computed Tomography with Dimensions of the Producers of the Implants.

    PubMed

    Repesa, Merisa; Sofic, Amela; Jakupovic, Selma; Tosum, Selma; Kazazic, Lejla; Dervisevic, Almir

    2017-06-01

    One of the most frequently used method for scanning patients with indication for dental implantation in dentistry is cone beam computed tomography. Implantation, CBCT imaging and implant programme are inevitable when planning a successful replacement of lost teeth. CBCT offers exact information about available bone and its density, adjacent tooth roots, the place of mandibular canal and maxillary sinus and adjacent anatomical structure. The goal of this study is to estimate accuracy of measurements on CBCT images ofpatients who have implants of different producers and determine if there is any statistically significant correlation between four test groups regardless of the alloy of which implants are made. The study was a prospective-comparative, and included fifteen patients with hundred dental implants divided in four groups depending on the producer. Over dimensioning in the gained measurements of the whole sample on CBCT images in relation to dimensions of producers is between 0.1006mm and 0.368mm. Even though over dimensioning is measured in millimetres, it has to be taken into consideration in clinical practice when planning an implant placement, and we can recommend safety zone of 0.5mm. There have been no statistically significant differences in the gained results in over dimensioning of implants of different alloys for horizontal and vertical measurements on CBCT images of Astra Tech, Brendet titanium implants and Straumann titanium-zirconium implants. Based on the goals of the study there have been confirmed statistically significant correlations of great value (from 0.841 to 0.936) of high level of importance between manufactured value of dimensions and average dimensions values gained through CBCT imaging in four types of implants (four test groups). The total exactness of measurements on CBCT scan in this research is 96.66% for horizontal measuring and 96.92% for vertical measuring. Therefore, we can conclude that CBCT as radiological method has an

  3. Influence of die geometry and material selection on the behavior of protective die covers in closed-die forging

    NASA Astrophysics Data System (ADS)

    Yu, Yingyan; Rosenstock, Dirk; Wolfgarten, Martin; Hirt, Gerhard

    2016-10-01

    Due to the fact that tooling costs make up to 30% of total costs of the final forged part, the tool life is always one main research topic in closed-die forging [1]. To improve the wear resistance of forging dies, many methods like nitriding and deposition of ceramic layers have been used. However, all these methods will lose its effect after a certain time, then tool repair or exchange is needed, which requires additional time and costs. A new method, which applies an inexpensive and changeable sheet metal on the forging die to protect it from abrasive wear, was firstly proposed in [2]. According to the first investigation, the die cover is effective for decreasing thermal and mechanical loads, but there are still several challenges to overcome in this concept, like wrinkling and thinning of the die cover. Therefore, an experimental study using different geometries and die cover materials is presented within this work. The results indicate the existence of feasible application cases of this concept, since conditions are found under which a die cover made of 22MnB5 still keeps its original shape even after 7 forging cycles.

  4. Stress distribution in Co-Cr implant frameworks after laser or TIG welding.

    PubMed

    de Castro, Gabriela Cassaro; de Araújo, Cleudmar Amaral; Mesquita, Marcelo Ferraz; Consani, Rafael Leonardo Xediek; Nóbilo, Mauro Antônio de Arruda

    2013-01-01

    Lack of passivity has been associated with biomechanical problems in implant-supported prosthesis. The aim of this study was to evaluate the passivity of three techniques to fabricate an implant framework from a Co-Cr alloy by photoelasticity. The model was obtained from a steel die simulating an edentulous mandible with 4 external hexagon analog implants with a standard platform. On this model, five frameworks were fabricated for each group: a monoblock framework (control), laser and TIG welding frameworks. The photoelastic model was made from a flexible epoxy resin. On the photoelastic analysis, the frameworks were bolted onto the model for the verification of maximum shear stress at 34 selected points around the implants and 5 points in the middle of the model. The stresses were compared all over the photoelastic model, between the right, left, and center regions and between the cervical and apical regions. The values were subjected to two-way ANOVA, and Tukey's test (α=0.05). There was no significant difference among the groups and studied areas (p>0.05). It was concluded that the stresses generated around the implants were similar for all techniques.

  5. Outcomes of Cranioplasty with Preformed Titanium versus Freehand Molded Polymethylmethacrylate Implants.

    PubMed

    Höhne, Julius; Werzmirzowsky, Korbinian; Ott, Christian; Hohenberger, Christoph; Hassanin, Bahaa Ghareb; Brawanski, Alexander; Schebesch, Karl-Michael

    2018-05-01

     Cranioplasty reshapes the neurocranium and viscerocranium after craniectomy. Different materials have been used for cranioplasty. However, no consistent data are yet available comparing these different materials regarding indications, complications, and outcome. We report our experience with preformed titanium implants and freehand molded polymethylmethacrylate (PMMA) implants for cranioplasty.  This retrospective single-center analysis included 120 consecutive cranioplasty patients who had been operated between 2006 and 2013. A total of 60 patients (27 women, 33 men; mean age: 54 years) had received a preformed titanium implant and 60 patients (22 women, 38 men; mean age: 46 years) a freehand molded PMMA implant. We evaluated all demographic and procedure-related data, indications, and outcome. The longest follow-up was 5.5 years.  The most frequent indications for cranioplasty were trauma ( n  = 48 [40%]), malignant infarction ( n  = 27 [23%]), tumor ( n  = 22 [18%]), spontaneous intracerebral or aneurysmal subarachnoid hemorrhage ( n  = 16 [13%]), revision surgery ( n  = 5 [4%]), and empyema ( n  = 2 [2%]). PMMA implants were more often associated with wound-healing disorders ( p  < 0.023; odds ratio [OR]: 10.53) and epidural hematoma ( p  < 0.03; OR: 8.46), resulting in a significantly higher re-operation rate ( p  < 0.005). Precise fitting was radiologically confirmed in 98% of titanium implants but in only 71% of PMMA implants ( p  < 0.001). Magnetic resonance imaging of patients with titanium implants ( n  = 4) did not show any relevant artifacts.  Cranioplasty with preformed titanium implants seems to be superior to freehand molded PMMA implants regarding surgical morbidity, revision rate, and aesthetic results. Georg Thieme Verlag KG Stuttgart · New York.

  6. Die Sonne.

    NASA Astrophysics Data System (ADS)

    der Time-Life Bücher, Redaktion

    Contents: 1. Das Antlitz der Sonne. Ein kosmisches Kraftwerk. 2. Erforschung des Innern. Die Beobachtung des Zentralgestirns. 3. Der unstete Nachbar. Geschenke des Sonnenlichts. 4. Ein endloser Partikelstrom. Die Kraft eines solaren Sturms.

  7. Magnetic resonance imaging metallic artifact of commonly encountered surgical implants and foreign material.

    PubMed

    Sutherland-Smith, James; Tilley, Brenda

    2012-01-01

    Magnetic resonance imaging (MRI) artifacts secondary to metallic implants and foreign bodies are well described. Herein, we provide quantitative data from veterinary implants including total hip arthroplasty implants, cranial cruciate repair implants, surgical screws, a skin staple, ligation clips, an identification microchip, ameroid constrictor, and potential foreign bodies including air gun and BB projectiles and a sewing needle. The objects were scanned in a gelatin phantom with plastic grid using standardized T2-weighted turbo-spin echo (TSE), T1-weighted spin echo, and T2*-weighted gradient recalled echo (GRE) image acquisitions at 1.5 T. Maximum linear dimensions and areas of signal voiding and grid distortion were calculated using a DICOM workstation for each sequence and object. Artifact severity was similar between the T2-weighted TSE and T1-weighted images, while the T2*-weighted images were most susceptible to artifact. Metal type influenced artifact size with the largest artifacts arising from steel objects followed by surgical stainless steel, titanium, and lead. For animals with metallic surgical implants or foreign bodies, the quantification of the artifact size will help guide clinicians on the viability of MRI. © 2012 Veterinary Radiology & Ultrasound.

  8. Die singulation method

    DOEpatents

    Swiler, Thomas P.; Garcia, Ernest J.; Francis, Kathryn M.

    2013-06-11

    A method is disclosed for singulating die from a semiconductor substrate (e.g. a semiconductor-on-insulator substrate or a bulk silicon substrate) containing an oxide layer (e.g. silicon dioxide or a silicate glass) and one or more semiconductor layers (e.g. monocrystalline or polycrystalline silicon) located above the oxide layer. The method etches trenches through the substrate and through each semiconductor layer about the die being singulated, with the trenches being offset from each other around at least a part of the die so that the oxide layer between the trenches holds the substrate and die together. The trenches can be anisotropically etched using a Deep Reactive Ion Etching (DRIE) process. After the trenches are etched, the oxide layer between the trenches can be etched away with an HF etchant to singulate the die. A release fixture can be located near one side of the substrate to receive the singulated die.

  9. Die singulation method

    DOEpatents

    Swiler, Thomas P [Albuquerque, NM; Garcia, Ernest J [Albuquerque, NM; Francis, Kathryn M [Rio Rancho, NM

    2014-01-07

    A method is disclosed for singulating die from a semiconductor substrate (e.g. a semiconductor-on-insulator substrate or a bulk silicon substrate) containing an oxide layer (e.g. silicon dioxide or a silicate glass) and one or more semiconductor layers (e.g. monocrystalline or polycrystalline silicon) located above the oxide layer. The method etches trenches through the substrate and through each semiconductor layer about the die being singulated, with the trenches being offset from each other around at least a part of the die so that the oxide layer between the trenches holds the substrate and die together. The trenches can be anisotropically etched using a Deep Reactive Ion Etching (DRIE) process. After the trenches are etched, the oxide layer between the trenches can be etched away with a HF etchant to singulate the die. A release fixture can be located near one side of the substrate to receive the singulated die.

  10. Application of the Vibrant Soundbridge middle-ear implant for aural atresia in patients with Treacher Collins syndrome.

    PubMed

    Lesinskas, E; Stankeviciute, V; Petrulionis, M

    2012-12-01

    To present results for the auditory rehabilitation of patients with Treacher Collins syndrome with bilateral osseous atresia, using middle-ear implantation with a Vibrant Soundbridge. Three patients underwent vibroplasty for aural atresia with moderate to severe conductive hearing loss. The pre-operative Jahrsdoerfer radiological score was 4 for all patients. Patients underwent active middle-ear implantation of a Vibrant Soundbridge implant (coupling the floating mass transducer to the rudimentary stapes or footplate distally, and positioning it adjacent to the round window membrane proximally), with audiological analysis as follow up. After implant activation, the mean air conduction threshold ± standard deviation decreased to 22.8 ± 5.5 dB HL, representing a mean functional gain of 44.5 dB. The mean word recognition score (for bisyllabic words at 65 dB SPL) increased from 0 to 97 per cent. Vibrant Soundbridge implantation is an effective hearing rehabilitation procedure in patients with Treacher Collins syndrome with bilateral osseous atresia. This is a versatile implant which can achieve coupling even in cases of severe middle-ear malformation.

  11. Influence of semipermanent cement application used in immediately loaded, implant-supported restorations on crestal bone resorption.

    PubMed

    Błaszczyszyn, Artur; Kubasiewicz-Ross, Paweł; Gedrange, Tomasz; Dominiak, Marzena

    2013-01-01

    The paper presents clinical-radiological research on the impact of the new semi-cement luting agent in the immediately loaded implant-supported restoration on alveolar ridge resorption. 25 patients with a partially edentulous alveolar ridge in the anterior section of the maxilla or mandible were included in the study. The implants were inserted with the application of traditional burs or with a Piezosurgery device supplied by Mectron. Taking into account the method of implant bed preparation, the scientific material was divided into two groups. The implants were loaded immediately with single crown restorations cemented with the Implantlink semi cement application. The following indices were taken into consideration: pocket depth around implant calculated at four measuring points, marginal alveolar bone loss measured using radio-visiography, the 3-degree Wachtel scale of healing of the soft tissue. In addition, the presence and possible width or height of any recession around the implants was measured. The success of the implant treatment was assessed according to the Albrektsson success criteria. The research results were subjected to statistical analysis. The results of our study revealed no influence of the Implant-link semi cement on the crestal bone level, regardless of the bone bed preparation technique.

  12. Breast implant capsule-associated squamous cell carcinoma: a report of 2 cases.

    PubMed

    Olsen, Daniel L; Keeney, Gary L; Chen, Beiyun; Visscher, Daniel W; Carter, Jodi M

    2017-09-01

    The use of prosthetic implants for breast augmentation has become commonplace. Although implants do not increase the risk of conventional mammary carcinoma, they are rarely associated with anaplastic large cell lymphoma. We report 2 cases of breast implant capsule-associated squamous cell carcinoma with poor clinical outcomes. Both patients (56-year-old woman and 81-year-old woman) had long-standing implants (>25 years) and presented with acute unilateral breast enlargement. In both cases, squamous cell carcinoma arose in (focally dysplastic) squamous epithelium-lined breast implant capsules and widely invaded surrounding breast parenchyma or chest wall. Neither patient had evidence of a primary mammary carcinoma or squamous cell carcinoma at any other anatomic site. Within 1 year, one patient developed extensive, treatment-refractory, locoregional soft tissue metastasis, and the second patient developed hepatic and soft tissue metastases and died of disease. There are 2 prior reported cases of implant-associated squamous cell carcinoma in the plastic surgery literature; one provides no pathologic staging or outcome information, and the second case was a capsule-confined squamous cell carcinoma. Together, all 4 cases share notable commonalities: the patients had long-standing breast implants and presented with acute unilateral breast pain and enlargement secondary to tumors arising on the posterior aspect of squamous epithelialized implant capsules. Because of both its rarity and its unusual clinical presentation, implant capsule-associated squamous cell carcinoma may be underrecognized. The aggressive behavior of the tumors in this series underscores the importance of excluding malignancy in patients with long-standing breast implants who present with acute unilateral breast pain and enlargement. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Correlation-based pattern recognition for implantable defibrillators.

    PubMed Central

    Wilkins, J.

    1996-01-01

    An estimated 300,000 Americans die each year from cardiac arrhythmias. Historically, drug therapy or surgery were the only treatment options available for patients suffering from arrhythmias. Recently, implantable arrhythmia management devices have been developed. These devices allow abnormal cardiac rhythms to be sensed and corrected in vivo. Proper arrhythmia classification is critical to selecting the appropriate therapeutic intervention. The classification problem is made more challenging by the power/computation constraints imposed by the short battery life of implantable devices. Current devices utilize heart rate-based classification algorithms. Although easy to implement, rate-based approaches have unacceptably high error rates in distinguishing supraventricular tachycardia (SVT) from ventricular tachycardia (VT). Conventional morphology assessment techniques used in ECG analysis often require too much computation to be practical for implantable devices. In this paper, a computationally-efficient, arrhythmia classification architecture using correlation-based morphology assessment is presented. The architecture classifies individuals heart beats by assessing similarity between an incoming cardiac signal vector and a series of prestored class templates. A series of these beat classifications are used to make an overall rhythm assessment. The system makes use of several new results in the field of pattern recognition. The resulting system achieved excellent accuracy in discriminating SVT and VT. PMID:8947674

  14. Protein biomarkers identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillators: findings from the Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSE-ICD).

    PubMed

    Cheng, Alan; Zhang, Yiyi; Blasco-Colmenares, Elena; Dalal, Darshan; Butcher, Barbara; Norgard, Sanaz; Eldadah, Zayd; Ellenbogen, Kenneth A; Dickfeld, Timm; Spragg, David D; Marine, Joseph E; Guallar, Eliseo; Tomaselli, Gordon F

    2014-12-01

    Primary prevention implantable cardioverter defibrillators (ICDs) reduce all-cause mortality, but the benefits are heterogeneous. Current risk stratification based on left ventricular ejection fraction has limited discrimination power. We hypothesize that biomarkers for inflammation, neurohumoral activation, and cardiac injury can predict appropriate shocks and all-cause mortality in patients with primary prevention ICDs. The Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSe-ICD) enrolled 1189 patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end point was an ICD shock for adjudicated ventricular tachyarrhythmia. The secondary end point was all-cause mortality. After a median follow-up of 4.0 years, 137 subjects experienced an appropriate ICD shock and 343 participants died (incidence rates of 3.2 and 5.8 per 100 person-years, respectively). In multivariable-adjusted models, higher interleukin-6 levels increased the risk of appropriate ICD shocks. In contrast, C-reactive protein, interleukin-6, tumor necrosis factor-α receptor II, pro-brain natriuretic peptide (pro-BNP), and cardiac troponin T showed significant linear trends for increased risk of all-cause mortality across quartiles. A score combining these 5 biomarkers identified patients who were much more likely to die than to receive an appropriate shock from the ICD. An increase in serum biomarkers of inflammation, neurohumoral activation, and myocardial injury increased the risk for death but poorly predicted the likelihood of an ICD shock. These findings highlight the potential importance of serum-based biomarkers in identifying patients who are unlikely to benefit from primary prevention ICDs. clinicaltrials.gov; Unique Identifier: NCT00733590. © 2014 American Heart Association, Inc.

  15. Imaging and radiology

    MedlinePlus

    Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...

  16. The thermal fatigue resistance of H-13 Die Steel for aluminum die casting dies

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The effects of welding, five selected surface coatings, and stress relieving on the thermal fatigue resistance of H-13 Die Steel for aluminum die casting dies were studied using eleven thermal fatigue specimens. Stress relieving was conducted after each 5,000 cycle interval at 1050 F for three hours. Four thermal fatigue specimens were welded with H-13 or maraging steel welding rods at ambient and elevated temperatures and subsequently, subjected to different post-weld heat treatments. Crack patterns were examined at 5,000, 10,000, and 15,000 cycles. The thermal fatigue resistance is expressed by two crack parameters which are the average maximum crack and the average cracked area. The results indicate that a significant improvement in thermal fatigue resistance over the control was obtained from the stress-relieving treatment. Small improvements were obtained from the H-13 welded specimens and from a salt bath nitrogen and carbon-surface treatment. The other surface treatments and welded specimens either did not affect or had a detrimental influence on the thermal fatigue properties of the H-13 die steel.

  17. Single crowns in the resorbed posterior maxilla supported by either 6-mm implants or by 11-mm implants combined with sinus floor elevation surgery: a 1-year randomised controlled trial.

    PubMed

    Guljé, Felix L; Raghoebar, Gerry M; Vissink, Arjan; Meijer, Henny J A

    2014-01-01

    The aim of this randomised controlled trial was to assess the clinical performance of single crowns in the posterior maxilla supported by either 6-mm or 11-mm implants combined with maxillary sinus floor elevation. 41 consecutive patients with one missing premolar or molar in the posterior maxilla and with an estimated bone height of 6 to 8 mm in that area were included. Each patient was randomly allocated to one of the two treatment groups, namely to receive an 11-mm implant (Osseo Speed 4.0 S, Dentsply Implants, Mölndal, Sweden) in combination with maxillary sinus floor elevation surgery or to receive a 6-mm implant (Osseo Speed 4.0 S) without any grafting. After a 3-month osseointegration period, all implants were restored with custom-made titanium abutments and cemented zirconia-based porcelain crowns. Outcome measures were: implant survival; radiographic bone changes; plaque accumulation; bleeding tendency; peri-implant inflammation; presence of dental calculus; biological and technical complications; and patients' satisfaction. Clinical and radiographic examinations were performed at placement of the crown and 12 months thereafter. Patients' satisfaction was scored before treatment and after 12 months of functioning of the crown. One patient of the 11 mm implant group died during the follow-up. No implant failed and no biological or technical complications occurred. From loading to the 12 months follow-up, no difference was found in mean marginal bone changes between the groups (bone resorption in both groups 0.1 ± 0.3 mm). Clinical items revealed very healthy peri-implant soft tissues in both groups. Patients' satisfaction scores were high in both groups. 6-mm implants and 11-mm implants combined with sinus floor elevation surgery are equally successful to support a single crown in the resorbed posterior maxilla after 1-year follow-up.

  18. Dimensional control of die castings

    NASA Astrophysics Data System (ADS)

    Karve, Aniruddha Ajit

    The demand for net shape die castings, which require little or no machining, is steadily increasing. Stringent customer requirements are forcing die casters to deliver high quality castings in increasingly short lead times. Dimensional conformance to customer specifications is an inherent part of die casting quality. The dimensional attributes of a die casting are essentially dependent upon many factors--the quality of the die and the degree of control over the process variables being the two major sources of dimensional error in die castings. This study focused on investigating the nature and the causes of dimensional error in die castings. The two major components of dimensional error i.e., dimensional variability and die allowance were studied. The major effort of this study was to qualitatively and quantitatively study the effects of casting geometry and process variables on die casting dimensional variability and die allowance. This was accomplished by detailed dimensional data collection at production die casting sites. Robust feature characterization schemes were developed to describe complex casting geometry in quantitative terms. Empirical modeling was utilized to quantify the effects of the casting variables on dimensional variability and die allowance for die casting features. A number of casting geometry and process variables were found to affect dimensional variability in die castings. The dimensional variability was evaluated by comparisons with current published dimensional tolerance standards. The casting geometry was found to play a significant role in influencing the die allowance of the features measured. The predictive models developed for dimensional variability and die allowance were evaluated to test their effectiveness. Finally, the relative impact of all the components of dimensional error in die castings was put into perspective, and general guidelines for effective dimensional control in the die casting plant were laid out. The results of

  19. Radiological assessment of the breast following enhancement with Macrolane: Managing the challenges.

    PubMed

    Scaperrotta, Gianfranco; Satchithananda, Keshtra; Tengvar, Magnus; Post, Karin; Lim, Adrian K; Panizza, Pietro; Wesolowska, Ewa; Inglefield, Christopher J

    2017-01-01

    Macrolane VRF ® , a biodegradable, stabilized hyaluronic acid gel, was used for breast enhancement 2008-2012. Similar to permanent implants, the presence of Macrolane gel may interfere with interpretation of mammography. This short communication aims to provide a guide to the appearance of Macrolane on radiology examination (including mammography, ultrasound and magnetic resonance imaging) and aid selection of the most appropriate imaging modality to facilitate breast examination in women who have undergone Macrolane breast enhancement. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Cardiac implantable electronic device infection due to Mycobacterium species: a case report and review of the literature.

    PubMed

    Al-Ghamdi, Bandar; Widaa, Hassan El; Shahid, Maie Al; Aladmawi, Mohammed; Alotaibi, Jawaher; Sanei, Aly Al; Halim, Magid

    2016-08-24

    Infection of cardiac implantable electronic devices is a serious cardiovascular disease and it is associated with a high mortality. Mycobacterium species may rarely cause cardiac implantable electronic devices infection. We are reporting a case of miliary tuberculosis in an Arab patient with dilated cardiomyopathy and a cardiac resynchronization therapy-defibrillator device that was complicated with infection of his cardiac resynchronization therapy-defibrillator device. To our knowledge, this is the third case in the literature with such a presentation and all patients died during the course of treatment. This underscores the importance of early diagnosis and management. We also performed a literature review of reported cases of cardiac implantable electronic devices infection related to Mycobacterium species. Cardiac implantable electronic devices infection due to Mycobacterium species is an uncommon but a well-known entity. Early diagnosis and prompt management may result in a better outcome.

  1. Outcomes and special considerations of cochlear implantation in waardenburg syndrome.

    PubMed

    Kontorinis, Georgios; Lenarz, Thomas; Giourgas, Alexandros; Durisin, Martin; Lesinski-Schiedat, Anke

    2011-08-01

    The objective of this study was a state-of-the-art analysis of cochlear implantation in patients with Waardenburg syndrome (WS). Twenty-five patients with WS treated with cochlear implants in our department from 1990 to 2010. The 25 patients with WS underwent 35 cochlear implantations. Hearing outcome was evaluated using HSM sentence test in 65 dB in quiet, Freiburg Monosyllabic Test, and categories of auditory performance for children and compared with that of a control group. Anatomic abnormalities of the inner ear were examined using magnetic resonance imaging and computed tomography of the temporal bones. The mean follow-up time was 8.3 years (range, 0.3-18.3 yr). The majority achieved favorable postimplantation performance with mean HSM scores of 75.3% (range, 22.6%-99%) and Freiburg Monosyllabic Test scores of 67.8% (range, 14%-95%). However, in 4 cases, the results were less satisfactory. The comparison with the control group did not reveal any statistical significance (p = 0.56). In 6 patients (24%), behavioral disorders caused temporary difficulties during the rehabilitation procedure. Except of isolated large vestibule in 1 patient, the radiological assessment of the 50 temporal bones did not reveal any temporal bone abnormalities. Most patients with WS performed well with cochlear implants. However, WS is related to behavioral disorders that may cause temporary rehabilitation difficulties. Finally, temporal bone malformations that could affect cochlear implantation are notcharacteristic of WS.

  2. Stem cell implantation for osteonecrosis of the femoral head.

    PubMed

    Lim, Young Wook; Kim, Yong Sik; Lee, Jong Wook; Kwon, Soon Yong

    2013-11-15

    What is the most effective treatment for the early stages of osteonecrosis of the femoral head? We assessed multiple drilling and stem cell implantation to treat the early stages of osteonecrosis of the femoral head. We report the clinical and radiological results of stem cell implantation and core decompression. In total, 128 patients (190 hips) who had undergone surgery were divided into two groups based on which treatment they had received: (1) multiple drilling and stem cell implantation or (2) core decompression, curettage and a bone graft. The clinical and radiographic results of the two groups were compared. At 5-year follow-up, in the stem cell implantation group, 64.3% (27/42) of the patients with Stage IIa disease, 56.7% (21/37) of the patients with Stage IIb disease and 42.9% (21/49) of the patients with Stage III disease had undergone no additional surgery. In the conventional core decompression group, 64.3% (9/14) of the patients with Stage IIa disease, 55.6% (5/9) of the patients with Stage IIb disease and 37.5% (3/8) of the patients with Stage III disease had undergone no additional surgery. Success rates were higher in patients with Ficat Stage I or II lesions than in those with Stage III lesions. There were no statistically significant differences between the groups in terms of success rate or in the clinical and radiographic results of the two methods. Essentially the same results were found with stem cell implantation as with the conventional method of core decompression.

  3. Assisted Dying & Disability.

    PubMed

    Riddle, Christopher A

    2017-07-01

    This article explores at least two dominant critiques of assisted dying from a disability rights perspective. In spite of these critiques, I conclude that assisted dying ought to be permissible. I arrive at the conclusion that if we respect and value people with disabilities, we ought to permit assisted dying. I do so in the following manner. First, I examine recent changes in legislation that have occurred since the Royal Society of Canada Expert Panel on End-of-Life Decision-Making report, published in this journal. I suggest that these changes are likely to only strengthen opposition to assisted dying from disability rights activists and people with disabilities. Second, I focus on respect for people with disabilities and in particular, respect for their autonomy and decision-making abilities. Third, I explore the opposition to assisted dying that focuses on risk and the vulnerability of people with disabilities. Here I suggest that this risk ought not to be of special concern. Ultimately, I conclude that upholding respect for the disabled requires the legalization of assisted dying, rather than the denial of access in a misguided effort to protect people with disabilities. © 2017 John Wiley & Sons Ltd.

  4. Micromechanical die attachment surcharge

    DOEpatents

    Filter, William F.; Hohimer, John P.

    2002-01-01

    An attachment structure is disclosed for attaching a die to a supporting substrate without the use of adhesives or solder. The attachment structure, which can be formed by micromachining, functions purely mechanically in utilizing a plurality of shaped pillars (e.g. round, square or polygonal and solid, hollow or slotted) that are formed on one of the die or supporting substrate and which can be urged into contact with various types of mating structures including other pillars, a deformable layer or a plurality of receptacles that are formed on the other of the die or supporting substrate, thereby forming a friction bond that holds the die to the supporting substrate. The attachment structure can further include an alignment structure for precise positioning of the die and supporting substrate to facilitate mounting the die to the supporting substrate. The attachment structure has applications for mounting semiconductor die containing a microelectromechanical (MEM) device, a microsensor or an integrated circuit (IC), and can be used to form a multichip module. The attachment structure is particularly useful for mounting die containing released MEM devices since these devices are fragile and can otherwise be damaged or degraded by adhesive or solder mounting.

  5. Sputtered protective coatings for die casting dies

    NASA Technical Reports Server (NTRS)

    Mirtich, M. J.; Nieh, C.-Y.; Wallace, J. F.

    1981-01-01

    Three experimental research designs investigating candidate materials and processes involved in protective die surface coating procedures by sputter deposition, using ion beam technologies, are discussed. Various pre-test results show that none of the coatings remained completely intact for 15,000 test cycles. The longest lifetime was observed for coatings such as tungsten, platinum, and molybdenum which reduced thermal fatigue, but exhibited oxidation and suppressed crack initiation only as long as the coating did not fracture. Final test results confirmed earlier findings and coatings with Pt and W proved to be the candidate materials to be used on a die surface to increase die life. In the W-coated specimens, which remained intact on the surface after thermal fatigue testing, no oxidation was found under the coating, although a few cracks formed on the surface where the coating broke down. Further research is planned.

  6. Displacement of a dental implant into the maxillary sinus after internal sinus floor elevation: report of a case and review of literature.

    PubMed

    Ding, Xiaojun; Wang, Qing; Guo, Xuehua; Yu, Youcheng

    2015-01-01

    Dental implant placement in the posterior maxilla may be complicated by implant migration into the maxillary sinus. To report the clinical and radiological characteristics of a patient who experienced dental implant displacement into the maxillary sinus following sinus floor elevation, and to compare our findings with those of other published reports of the displacement of dental implants. Implant placement and maxillary sinus elevation were performed simultaneously. The location of the displaced implant was monitored for 8 years, until the ectopic implant was surgically removed using the lateral window approach. The contributing factors, treatment modality, and clinical outcome for our patient were compared with those of patients reported in the literature. The clinical characteristics of our case were similar to those of patients with displaced implants who were also asymptomatic for long periods. The clinical outcome of our case was consistent with that of patients who underwent similar surgeries. Transnasal endoscopic removal of an ectopic implant may be suitable in cases in which the ectopic implant is accessible. Transoral direct approaches are adequate in most cases in which endoscopic approaches may be confounded. The bony-window transoral technique may allow the removal of large implants.

  7. Cardioverter-defibrillator implantation in myeloma-associated cardiac amyloidosis

    PubMed Central

    Campanile, Alfonso; Sozzi, Fabiola B; Canetta, Ciro; Danzi, Gian Battista

    2013-01-01

    A 62-year-old woman with multiple myeloma and light-chain amyloidosis with significant heart involvement developed an in-hospital cardiac arrest. After cardiopulmonary resuscitation, a stable sinus rhythm without any cerebral damage was restored, and the patient was admitted to the coronary care unit. A cardioverter-defibrillator was implanted, and it successfully intervened in two sustained ventricular tachycardia episodes and one ventricular fibrillation episode, which were recorded during hospitalization. After achieving discrete cardiac compensation, the patient was transferred to the emergency medicine department where she underwent chemotherapy for multiple myeloma. The patient died 40 days after admission from refractory heart failure. In the literature, there are studies that describe the use of cardioverter-defibrillator implantation in cardiac amyloidosis; however, at present, there is no evidence of a beneficial effect on survival with the use of this intervention. A high index of suspicion for amyloid heart disease and early diagnosis are critical to improving outcomes. PMID:24294034

  8. Cardioverter-defibrillator implantation in myeloma-associated cardiac amyloidosis.

    PubMed

    Campanile, Alfonso; Sozzi, Fabiola B; Canetta, Ciro; Danzi, Gian Battista

    2013-01-01

    A 62-year-old woman with multiple myeloma and light-chain amyloidosis with significant heart involvement developed an in-hospital cardiac arrest. After cardiopulmonary resuscitation, a stable sinus rhythm without any cerebral damage was restored, and the patient was admitted to the coronary care unit. A cardioverter-defibrillator was implanted, and it successfully intervened in two sustained ventricular tachycardia episodes and one ventricular fibrillation episode, which were recorded during hospitalization. After achieving discrete cardiac compensation, the patient was transferred to the emergency medicine department where she underwent chemotherapy for multiple myeloma. The patient died 40 days after admission from refractory heart failure. In the literature, there are studies that describe the use of cardioverter-defibrillator implantation in cardiac amyloidosis; however, at present, there is no evidence of a beneficial effect on survival with the use of this intervention. A high index of suspicion for amyloid heart disease and early diagnosis are critical to improving outcomes.

  9. Outcomes in African Americans undergoing cardioverter-defibrillator implantation for primary prevention of sudden cardiac death: findings from the Prospective Observational Study of Implantable Cardioverter-Defibrillators (PROSE-ICD).

    PubMed

    Zhang, Yiyi; Kennedy, Robert; Blasco-Colmenares, Elena; Butcher, Barbara; Norgard, Sanaz; Eldadah, Zayd; Dickfeld, Timm; Ellenbogen, Kenneth A; Marine, Joseph E; Guallar, Eliseo; Tomaselli, Gordon F; Cheng, Alan

    2014-08-01

    Implantable cardioverter-defibrillators (ICDs) reduce the risk of death in patients with left ventricular dysfunction. Little is known regarding the benefit of this therapy in African Americans (AAs). The purpose of this study was to determine the association between AA race and outcomes in a cohort of primary prevention ICD patients. We conducted a prospective cohort study of patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end-point was appropriate ICD shock defined as a shock for rapid ventricular tachyarrhythmias. The secondary end-point was all-cause mortality. There were 1189 patients (447 AAs and 712 non-AAs) enrolled. Over a median follow-up of 5.1 years, a total of 137 patients experienced an appropriate ICD shock, and 343 died (294 of whom died without receiving an appropriate ICD shock). The multivariate adjusted hazard ratio (95% confidence interval) comparing AAs vs non-AAs were 1.24 (0.96-1.59) for all-cause mortality, 1.33 (1.02, 1.74) for all-cause mortality without receiving appropriate ICD shock, and 0.78 (0.51, 1.19) for appropriate ICD shock. Ejection fraction, diabetes, and hypertension appeared to explain 24.1% (10.1%-69.5%), 18.7% (5.3%-58.0%), and 13.6% (3.8%-53.6%) of the excess risk of mortality in AAs, with a large proportion of the mortality difference remaining unexplained. In patients with primary prevention ICDs, AAs had an increased risk of dying without receiving an appropriate ICD shock compared to non-AAs. Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. Radiology research in mainland China in the past 10 years: a survey of original articles published in Radiology and European Radiology.

    PubMed

    Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Schoepf, U Joseph; Xu, Jiaqian; Lu, Guang Ming; Li, Enzhong

    2017-10-01

    To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. • Radiology research in Mainland China saw a substantial increase. • Neuroradiology, vascular/interventional Radiology, and abdominal Radiology are the most productive fields. • MRI is the most used modality in Mainland China's Radiology research. • Guangdong, Shanghai, and Beijing are the most productive provinces.

  11. Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research.

    PubMed

    Bornstein, Michael M; Horner, Keith; Jacobs, Reinhilde

    2017-02-01

    Diagnostic radiology is an essential component of treatment planning in the field of implant dentistry. This narrative review will present current concepts for the use of cone beam computed tomography imaging, before and after implant placement, in daily clinical practice and research. Guidelines for the selection of three-dimensional imaging will be discussed, and limitations will be highlighted. Current concepts of radiation dose optimization, including novel imaging modalities using low-dose protocols, will be presented. For preoperative cross-sectional imaging, data are still not available which demonstrate that cone beam computed tomography results in fewer intraoperative complications such as nerve damage or bleeding incidents, or that implants inserted using preoperative cone beam computed tomography data sets for planning purposes will exhibit higher survival or success rates. The use of cone beam computed tomography following the insertion of dental implants should be restricted to specific postoperative complications, such as damage of neurovascular structures or postoperative infections in relation to the maxillary sinus. Regarding peri-implantitis, the diagnosis and severity of the disease should be evaluated primarily based on clinical parameters and on radiological findings based on periapical radiographs (two dimensional). The use of cone beam computed tomography scans in clinical research might not yield any evident beneficial effect for the patient included. As many of the cone beam computed tomography scans performed for research have no direct therapeutic consequence, dose optimization measures should be implemented by using appropriate exposure parameters and by reducing the field of view to the actual region of interest. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Stentgraft Implantation for the Treatment of Postoperative Hepatic Artery Pseudoaneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pedersoli, F., E-mail: fpedersoli@ukaachen.de; Isfort, P.; Keil, S.

    PurposeHepatic artery pseudoaneurysms are a rare but potentially life-threatening complication of major pancreaticobiliary surgery. We evaluated the safety and efficacy of endovascular stentgraft implantation for the management of such vascular lesions.Materials and MethodsBetween May 2013 and October 2015, ten patients with postoperative hepatic artery pseudoaneurysm, of which eight presented with active hemorrhage, were treated with endovascular stentgraft implantation. All patients had undergone major pancreatic or hepatic surgery before (pylorus-preserving pancreaticoduodenectomy, pancreatectomy, hemihepatectomy, extended hemihepatectomy). The pseudoaneurysms were diagnosed 13–202 days after surgery and were associated with postsurgical complications (e.g., leakage of pancreaticojejunal anastomosis).ResultsIn 9/10 patients, the pseudoaneurysm was completely excluded viamore » stentgraft implantation. In 1/10 patient, the pseudoaneurysm ruptured during the procedure and was successfully treated by immediate open surgery. In 1/10 patient, a second intervention was performed after 6 days because of rebleeding; this was successfully treated by implantation of a second overlapping stentgraft. Mean follow-up time is 51 days. None of the patients died due to stentgraft- or aneurysm-related complications. Further episodes of hemorrhage were not observed. In one patient, clinically asymptomatic complete occlusion of the stentgraft was discovered at follow-up imaging.ConclusionStentgraft implantation is a safe and effective technique to treat hepatic artery pseudoaneurysms related to major pancreatic or hepatic surgery, especially in the setting of acute hemorrhage.« less

  13. Single-blind randomized clinical trial to evaluate clinical and radiological outcomes after one year of immediate versus delayed implant placement supporting full-arch prostheses

    PubMed Central

    Pellicer-Chover, Hilario; Peñarrocha-Oltra, David; Bagán, Leticia; Fichy-Fernandez, Antonio J.; Canullo, Luigi

    2014-01-01

    Purpose: To evaluate and compare peri-implant health, marginal bone loss and success of immediate and delayed implant placement for rehabilitation with full-arch fixed prostheses. Material and Methods: The present study was a prospective, randomized, single-blind, clinical preliminary trial. Patients were randomized into two treatment groups. In Group A implants were placed immediately post-extraction and in Group B six months after extraction. The following control time-points were established: one week, six months and twelve months after loading. Measurements were taken of peri-implant crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified gingival index and presence of mucositis. Implant success rates were evaluated for the two groups. The study sample included fifteen patients (nine women and six men) with a mean average age of 63.7 years. One hundred and forty-four implants were placed: 76 placed in healed sites and 68 placed immediately. Results: At the moment of prosthetic loading, keratinized mucosa width and probing depth were higher in immediate implants than delayed implants, with statistically significant differences. However, after six and twelve months, differences between groups had disappeared. Bone loss was 0.54 ± 0.39 mm for immediate implants and 0.66 ± 0.25 mm for delayed implants (p=0.201). No implants failed in either group. Conclusions: The present study with a short follow-up and a small sample yielded no statistically significant differences in implant success and peri-implant marginal bone loss between immediate and delayed implants with fixed full-arch prostheses. Peri-implant health showed no statistically significant differences for any of the studied parameters (crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified gingival index and presence of mucositis) at the twelve-month follow-up. Key words:Immediate implants, delayed implants

  14. Pedicle screw loosening is correlated to chronic subclinical deep implant infection: a retrospective database analysis.

    PubMed

    Leitner, Lukas; Malaj, Isabella; Sadoghi, Patrick; Amerstorfer, Florian; Glehr, Mathias; Vander, Klaus; Leithner, Andreas; Radl, Roman

    2018-04-13

    Spinal fusion is used for treatment of spinal deformities, degeneration, infection, malignancy, and trauma. Reduction of motion enables osseous fusion and permanent stabilization of segments, compromised by loosening of the pedicle screws (PS). Deep implant infection, biomechanical, and chemical mechanisms are suspected reasons for loosening of PS. Study objective was to investigate the frequency and impact of deep implant infection on PS loosening. Intraoperative infection screening from wound and explanted material sonication was performed during revision surgeries following dorsal stabilization. Case history events and factors, which might promote implant infections, were included in this retrospective survey. 110 cases of spinal metal explantation were included. In 29.1% of revision cases, infection screening identified a germ, most commonly Staphylococcus (53.1%) and Propionibacterium (40.6%) genus. Patients screened positive had a significant higher number of previous spinal operations and radiologic loosening of screws. Patients revised for adjacent segment failure had a significantly lower rate of positive infection screening than patients revised for directly implant associated reasons. Removal of implants that revealed positive screening effected significant pain relief. Chronic implant infection seems to play a role in PS loosening and ongoing pain, causing revision surgery after spinal fusion. Screw loosening and multiple prior spinal operations should be suspicious for implant infection after spinal fusion when it comes to revision surgery. These slides can be retrieved under Electronic Supplementary Material.

  15. Integration of implant planning workflows into the PACS infrastructure

    NASA Astrophysics Data System (ADS)

    Gessat, Michael; Strauß, Gero; Burgert, Oliver

    2008-03-01

    The integration of imaging devices, diagnostic workstations, and image servers into Picture Archiving and Communication Systems (PACS) has had an enormous effect on the efficiency of radiology workflows. The standardization of the information exchange between the devices with the DICOM standard has been an essential precondition for that development. For surgical procedures, no such infrastructure exists. With the increasingly important role computerized planning and assistance systems play in the surgical domain, an infrastructure that unifies the communication between devices becomes necessary. In recent publications, the need for a modularized system design has been established. A reference architecture for a Therapy Imaging and Model Management System (TIMMS) has been proposed. It was accepted by the DICOM Working Group 6 as the reference architecture for DICOM developments for surgery. In this paper we propose the inclusion of implant planning systems into the PACS infrastructure. We propose a generic information model for the patient specific selection and positioning of implants from a repository according to patient image data. The information models are based on clinical workflows from ENT, cardiac, and orthopedic surgery as well as technical requirements derived from different use cases and systems. We show an exemplary implementation of the model for application in ENT surgery: the selection and positioning of an ossicular implant in the middle ear. An implant repository is stored in the PACS. It makes use of an experimental implementation of the Surface Mesh Module that is currently being developed as extension to the DICOM standard.

  16. Dental implants placement in paranoid squizofrenic patient with obsessive-compulsive disorder: A case report

    PubMed Central

    Castellanos-Cosano, Lizett; Corcuera-Flores, José-Ramón; Mesa-Cabrera, María; Cabrera-Domínguez, José; Torres-Lagares, Daniel; Machuca-Portillo, Guillermo

    2017-01-01

    Background Paranoid schizophrenia is a mental illness that involves no observable anatomical alteration. Main characteristic affects the personality of the individual, as well as areas of his own psychology. Case Report A 33-year-old man with paranoid schizophrenia and obsessive-compulsive disorder in treatment with Haloperidol, Oxcarbazepine, Olanzapine and Seroquel is presented. Dental exploration showed widespread decay mostly cervical with numerous root fragments, agenesis of lateral incisors, impacted wisdom teeth, missing teeth and malocclusion. Treatment plan included restoration of teeth decay, extractions of root fragments and implant-supported prostheses in bilateral upper lateral incisors for aesthetics reason. A previous consultation with a psychiatric specialist was performed and no contraindication were observed. A preliminary radiological examination was performed previous dental treatment and implant placement. Due to patient refusal to replace dental abscenses with implants, inform consent was signed up from his parents. After local anesthesia, first implant was placed at upper right lateral positions (Straumann Bone Level Ø 3.3 mm, length 10 mm). Two weeks later a second implant was placed at upper left lateral position (Straumann Bone Level Ø 3.3 mm, length 12 mm). The patient showed no postoperative complications. After implant placement, the patient attended scheduled review appointments. The prosthesis was placed after a 3-month period of osseointegration. Conclusions Implant placement can be considered a suitable option for people with mental disorders. A previous consultation with psychiatric specialists for conducting a good patient management is necessaire. Key words:Paranoid schizophrenia, obsessive-compulsive disorder, dental implants. PMID:29302292

  17. Experimental model of bone response to collagenized xenografts of porcine origin (OsteoBiol® mp3): a radiological and histomorphometric study.

    PubMed

    Calvo Guirado, Jose Luis; Ramírez Fernández, Maria Piedad; Negri, Bruno; Delgado Ruiz, Rafael Arcesio; Maté Sánchez de-Val, José Eduardo; Gómez-Moreno, Gerardo

    2013-02-01

    Adequate alveolar ridges are fundamental to successful rehabilitation with implants. There are diverse techniques for reconstructing atrophied ridges, of which bone substitute grafts is one possibility. The aim of this study was to carry out radiological and histomorphometric evaluations of bone response to collagenized porcine bone xenografts over a 4-month period following their insertion in rabbits' tibiae. Twenty New Zealand rabbits were used. Twenty collagenized porcine bone xenografts (Osteobiol® mp3, Tecnoss Dental s.r.l., Torino, Italy), in granulated form of 600 to 1,000 µm, were inserted in the proximal metaphyseal area of the animals' tibiae and 20 control areas were created. Following implantation, the animals were sacrificed in four groups of five, after 1, 2, 3, and 4 months, respectively. Radiological and histomorphometric studies were made. After 4 months, radiological images revealed bone defects with a decrease in graft volume and the complete repair of the osseous defect. No healed or residual bone alterations attributable to the presence of the implants were observed. Histomorphometric analysis at 4 months found mean values for newly formed bone, residual graft material, and non-mineralized connective tissue of 25.4 ± 1.8%, 36.37 ± 3.0%, and 38.22 ± 2.5%, respectively. There were no statistical differences in the length of cortical formation with collagenized porcine xenograft (98.9 ± 1.1%) compared with the control samples (99.1 ± 0.7%) at the end of the study period. The biomaterial used proved to be biocompatible, bioabsorbable, and osteoconductive and as such, a possible bone substitute that did not interfere with the bone's normal reparative processes. © 2011 Wiley Periodicals, Inc.

  18. Herausforderungen durch die deutsche Wiedervereinigung

    NASA Astrophysics Data System (ADS)

    Stäglin, Reiner

    Die Wiedervereinigung stellte auch die Statistik vor große Aufgaben. Die als Organ der staatlichen Planung staatsnah orientierte Statistik der DDR musste auf das zur Neutralität und wissenschaftlichen Unabhängigkeit verpflichtete System der Bundesrepublik umgestellt werden. Ebenso verlangten die Universitäten eine Neuorientierung. Die Deutsche Statistische Gesellschaft hat sich vor allem dreier Aufgaben mit großem Engagement, aber auch mit Bedachtsamkeit angenommen: Aufnahme und Integration der Statistiker aus den neuen Bundesländern in die Gesellschaft, Begleitung der Neuausrichtung des Faches Statistik an deren Hochschulen und Sicherung sowie Nutzung von Datenbeständen der ehemaligen DDR.

  19. Early infection risk with primary versus staged Hemodialysis Reliable Outflow (HeRO) graft implantation.

    PubMed

    Griffin, Andrew S; Gage, Shawn M; Lawson, Jeffrey H; Kim, Charles Y

    2017-01-01

    This study evaluated whether the use of a staged Hemodialysis Reliable Outflow (HeRO; Merit Medical, South Jordan, Utah) implantation strategy incurs increased early infection risk compared with conventional primary HeRO implantation. A retrospective review was performed of 192 hemodialysis patients who underwent HeRO graft implantation: 105 patients underwent primary HeRO implantation in the operating room, and 87 underwent a staged implantation where a previously inserted tunneled central venous catheter was used for guidewire access for the venous outflow component. Within the staged implantation group, 32 were performed via an existing tunneled hemodialysis catheter (incidentally staged), and 55 were performed via a tunneled catheter inserted across a central venous occlusion in an interventional radiology suite specifically for HeRO implantation (intentionally staged). Early infection was defined as episodes of bacteremia or HeRO infection requiring resection ≤30 days of HeRO implantation. For staged HeRO implantations, the median interval between tunneled catheter insertion and conversion to a HeRO graft was 42 days. The overall HeRO-related infection rate ≤30 days of implantation was 8.6% for primary HeRO implantation and 2.3% for staged implantations (P = .12). The rates of early bacteremia and HeRO resection requiring surgical resection were not significantly different between groups (P = .19 and P = .065, respectively), nor were age, gender, laterality, anastomosis to an existing arteriovenous access, human immunodeficiency virus status, diabetes, steroids, chemotherapy, body mass index, or graft location. None of the patient variables, techniques, or graft-related variables correlated significantly with the early infection rate. The staged HeRO implantation strategy did not result in an increased early infection risk compared with conventional primary implantation and is thus a reasonable strategy for HeRO insertion in hemodialysis patients

  20. Total Artificial Heart Implantation after Excision of Right Ventricular Angiosarcoma.

    PubMed

    Bruckner, Brian A; Abu Saleh, Walid K; Al Jabbari, Odeaa; Copeland, Jack G; Estep, Jerry D; Loebe, Matthias; Reardon, Michael J

    2016-06-01

    Primary cardiac sarcomas, although rare, are aggressive and lethal, requiring thorough surgical resection and adjuvant chemotherapy for the best possible outcome. We report the case of a 32-year-old woman who underwent total artificial heart implantation for right-sided heart failure caused by right ventricular angiosarcoma. For the first several weeks in intensive care, the patient recovered uneventfully. However, a postoperative liver biopsy indicated hepatocellular injury consistent with preoperative chemotherapy. She developed continuing liver failure, from which she died despite good cardiac function.

  1. Comparison of magnesium alloys and poly-l-lactide screws as degradable implants in a canine fracture model.

    PubMed

    Marukawa, Eriko; Tamai, Masato; Takahashi, Yukinobu; Hatakeyama, Ichiro; Sato, Masaru; Higuchi, Yusuke; Kakidachi, Hiroshi; Taniguchi, Hirofumi; Sakamoto, Takamitsu; Honda, Jun; Omura, Ken; Harada, Hiroyuki

    2016-10-01

    The aims of this study were to evaluate in vivo the biological responses to implants composed of biodegradable anodized WE43 (containing magnesium yttrium, rare earth elements and zirconium; Elektron SynerMag®) magnesium alloy, monolithic WE43 magnesium alloy and poly-l-lactic acid (PLLA), which are commonly used materials in clinic settings, and to evaluate the effectiveness of the materials as bone screws. The effectiveness of the magnesium alloy implants in osteosynthesis was evaluated using a bone fracture model involving the tibia of beagle dogs. For the monolithic WE43 implants, radiological, and histological evaluation revealed that bone trabeculae around the implanted monolithic WE43 decreased because of an inflammatory response. However, there was no damage due to hydrogen gas or inflammatory response in the bone tissue around the anodized WE43 implants. After 4 weeks, all the PLLA implants (n = 3) had broken but the WE43 implants had not (n = 6). These results suggest that the WE43 implants had sufficient strength to fix bone fractures at load-bearing sites in orthopedic and oral maxillofacial surgery. Therefore, these biodegradable magnesium alloys are good candidates for replacing biodegradable polymers. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1282-1289, 2016. © 2015 Wiley Periodicals, Inc.

  2. Radiological anatomy - evaluation of integrative education in radiology.

    PubMed

    Dettmer, S; Schmiedl, A; Meyer, S; Giesemann, A; Pabst, R; Weidemann, J; Wacker, F K; Kirchhoff, T

    2013-09-01

    Evaluation and analysis of the integrative course "Radiological Anatomy" established since 2007 at the Medical School Hannover (MHH) in comparison with conventional education. Anatomy and radiology are usually taught separately with a considerable time lag. Interdisciplinary teaching of these associated subjects seems logical for several reasons. Therefore, the integrative course "Radiological Anatomy" was established in the second year of medical education, combining these two closely related subjects. This interdisciplinary course was retrospectively evaluated by consideration of a student questionnaire and staff observations. The advantages and disadvantages of integrative teaching in medical education are discussed. The course ratings were excellent (median 1; mean 1.3 on a scale of 1 to 6). This is significantly (p < 0.001) better than the average of all evaluated courses in the respective term (grade 2.8). The course improved the anatomical comprehension (90 %) and the students stated that the topics were relevant for their future medical education (90 %). Furthermore, interest in the subject's anatomy and radiology increased during the course (88 %). According to the students' suggestions the course was enhanced by a visitation in the Department of Radiology and the additional topic central nervous system. Integrative teaching of anatomy and radiology was well received by the students. Both, anatomical and radiological comprehension and the motivation to learn were improved. However, it should be considered, that the amount of work and time required by the teaching staff is considerably increased compared to traditional teaching. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Short Implants: New Horizon in Implant Dentistry.

    PubMed

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  4. Abnormal bone formation induced by implantation of osteosarcoma-derived bone-inducing substance in the X-linked hypophosphatemic mouse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoshikawa, H.; Masuhara, K.; Takaoka, K.

    1985-01-01

    The X-linked hypophosphatemic mouse (Hyp) has been proposed as a model for the human familial hypophosphatemia (the most common form of vitamin D-resistant rickets). An osteosarcoma-derived bone-inducing substance was subcutaneously implanted into the Hyp mouse. The implant was consistently replaced by cartilage tissue at 2 weeks after implantation. The cartilage matrix seemed to be normal, according to the histological examination, and 35sulphur (TVS) uptake was also normal. Up to 4 weeks after implantation the cartilage matrix was completely replaced by unmineralized bone matrix and hematopoietic bone marrow. Osteoid tissue arising from the implantation of bone inducing substance in the Hypmore » mouse showed no radiologic or histologic sign of calcification. These findings suggest that the abnormalities of endochondral ossification in the Hyp mouse might be characterized by the failure of mineralization in cartilage and bone matrix. Analysis of the effects of bone-inducing substance on the Hyp mouse may help to give greater insight into the mechanism and treatment of human familial hypophosphatemia.« less

  5. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  6. Three-year outcome of a nonthoracotomy approach to cardioverter-defibrillator implantation in 189 consecutive patients.

    PubMed

    Brooks, R; Garan, H; Torchiana, D; Vlahakes, G J; Dziuban, S; Newell, J; McGovern, B A; Ruskin, J N

    1994-11-15

    To date, no long-term clinical data have been published in patients undergoing a nonthoracotomy approach to cardioverter-defibrillator system implantation. In the present report, 189 consecutive patients prospectively underwent a standardized approach to cardioverter-defibrillator system implantation in which the nonthoracotomy configurations were tested first. If satisfactory defibrillation thresholds were not obtained, thoracotomy was performed during the same intraoperative session. A nonthoracotomy system was successfully implanted in 149 of 189 patients (79%), with a higher success rate (90%) observed in patients who had more recent implantations. The overall rate of complications associated with these systems was low (11%). Over a mean follow-up of 12.5 +/- 9.3 months, 17 patients (9%) died. Three-year total, cardiac, and sudden death-free actuarial survival for all patients was 83 +/- 11%, 88 +/- 7%, and 94 +/- 2%, respectively. Three-year sudden death-free actuarial survival was higher in the nonthoracotomy than in the thoracotomy patients (97 +/- 2% vs 87 +/- 6%, p = 0.047), although total survival was similar (77 +/- 11% vs 83 +/- 7%, p = 0.77). These data suggest that a majority of patients (> 80%) requiring a cardioverter-defibrillator system can undergo implantation using a nonthoracotomy approach. Patients receiving nonthoracotomy systems have 3-year outcomes comparable to those implanted via thoracotomy. If these results are maintained, a nonthoracotomy approach will supplant thoracotomy-implanted systems as the preferred method because of the simpler implant procedure and lower overall cost involved.

  7. Short Implants: New Horizon in Implant Dentistry

    PubMed Central

    Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-01-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration. PMID:27790598

  8. [Transcatheter aortic valve implantation for aortic stenosis. Initial experience].

    PubMed

    Careaga-Reyna, Guillermo; Lázaro-Castillo, José Luis; Lezama-Urtecho, Carlos Alberto; Macías-Miranda, Enriqueta; Dosta-Herrera, Juan José; Galván Díaz, José

    Aortic stenosis is a frequent disease in the elderly, and is associated with other systemic pathologies that may contraindicate the surgical procedure. Another option for these patients is percutaneous aortic valve implantation, which is less invasive. We present our initial experience with this procedure. Patients with aortic stenosis were included once selection criteria were accomplished. Under general anaesthesia and echocardiographic and fluosocopic control, a transcatheter aortic valve was implanted following s valvuloplasty. Once concluded the procedure, angiographic and pressure control was realized in order to confirm the valve function. Between November 2014 and May 2015, 6 patients were treated (4 males and 2 females), with a mean age of 78.83±5.66 years-old. The preoperative transvalvular gradient was 90.16±28.53mmHg and posterior to valve implant was 3.33±2.92mmHg (P<.05). Two patients had concomitant coronary artery disease which had been treated previously. One patient presented with acute right coronary artery occlusion which was immediately treated. However due to previous renal failure, postoperative sepsis and respiratory failure, the patient died one month later. It was concluded that our preliminary results showed that in selected patients percutaneous aortic valve implantation is a safe procedure with clinical improvement for treated patients. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  9. Toward a distributed free-floating wireless implantable neural recording system.

    PubMed

    Pyungwoo Yeon; Xingyuan Tong; Byunghun Lee; Mirbozorgi, Abdollah; Ash, Bruce; Eckhardt, Helmut; Ghovanloo, Maysam

    2016-08-01

    To understand the complex correlations between neural networks across different regions in the brain and their functions at high spatiotemporal resolution, a tool is needed for obtaining long-term single unit activity (SUA) across the entire brain area. The concept and preliminary design of a distributed free-floating wireless implantable neural recording (FF-WINeR) system are presented, which can enabling SUA acquisition by dispersedly implanting tens to hundreds of untethered 1 mm3 neural recording probes, floating with the brain and operating wirelessly across the cortical surface. For powering FF-WINeR probes, a 3-coil link with an intermediate high-Q resonator provides a minimum S21 of -22.22 dB (in the body medium) and -21.23 dB (in air) at 2.8 cm coil separation, which translates to 0.76%/759 μW and 0.6%/604 μW of power transfer efficiency (PTE) / power delivered to a 9 kΩ load (PDL), in body and air, respectively. A mock-up FF-WINeR is implemented to explore microassembly method of the 1×1 mm2 micromachined silicon die with a bonding wire-wound coil and a tungsten micro-wire electrode. Circuit design methods to fit the active circuitry in only 0.96 mm2 of die area in a 130 nm standard CMOS process, and satisfy the strict power and performance requirements (in simulations) are discussed.

  10. Displaced capillary dies

    DOEpatents

    Kalejs, Juris P.; Chalmers, Bruce; Surek, Thomas

    1982-01-01

    An asymmetrical shaped capillary die made exclusively of graphite is used to grow silicon ribbon which is capable of being made into solar cells that are more efficient than cells produced from ribbon made using a symmetrically shaped die.

  11. Displaced capillary dies

    DOEpatents

    Kalejs, Juris P.; Chalmers, Bruce; Surek, Thomas

    1984-01-01

    An asymmetrical shaped capillary die made exclusively of graphite is used to grow silicon ribbon which is capable of being made into solar cells that are more efficient than cells produced from ribbon made using a symmetrically shaped die.

  12. Ventricular tachyarrhythmias and mortality in patients with an implantable cardioverter defibrillator: impact of depression in the MIDAS cohort.

    PubMed

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc; Theuns, Dominic A M J; Pedersen, Susanne S

    2014-01-01

    We examined whether depression is independently associated with implantable cardioverter defibrillator (ICD) therapy for ventricular tachyarrhythmias and mortality. A cohort of 430 consecutive patients with a first-time ICD (79% men; mean [standard deviation] age = 57.8 [12.1] years) completed the Hospital Anxiety and Depression Scale 1 day before implantation. During follow-up, the ICD was interrogated at 3-month intervals. Cox proportional hazard regression analyses were used to examine the impact of depression on time to first appropriate ICD therapy and all-cause mortality during a median follow-up period of 3.8 years. Of all patients, 108 (25.1%) were depressed. Depression was not associated with time to first appropriate ICD therapy (unadjusted hazard ratio [HR] = 1.07, 95% confidence interval [CI] = 0.73-1.56). However, depression was associated with an increased risk for all-cause mortality (unadjusted HR = 2.18, 95% CI = 1.36-3.49). Depression remained independently associated with all-cause mortality (HR = 1.94, 95% CI = 1.06-3.54, p = .031), after adjusting for demographic and clinical characteristics. Patients who remained depressed during the first 3 months after implantation were at greatest risk for dying (HR = 2.88, 95% CI = 1.29-6.45, p = .010). The current study showed that depression at the time of implant is not associated with time to first appropriate ICD therapy but almost doubled the risk for all-cause mortality in patients with an ICD. Patients with persistent depression during the first 3 months after implantation face the greatest risk of dying. Current evidence indicates that multifactorial interventions are likely to be the most successful in terms of reducing distress. Whether this translates into enhanced survival has yet to be determined.

  13. Wissenschaft, die unsere Kultur verändert. Tiefenschichten des Streits um die Evolutionstheorie

    NASA Astrophysics Data System (ADS)

    Patzelt, Werner J.

    Die Evolutionstheorie ist eine der erfolgreichsten wissenschaftlichen Theorien. Sie erlaubt es, unsere Herkunft zu verstehen und riskante Merkmale gerade der menschlichen Spezies zu begreifen. Zugleich ist die Evolutionstheorie eine der umstrittensten Theorien. Das liegt nicht an ihrer empirischen Tragfähigkeit, sondern an ihrem Gegenstand. Sie handelt nämlich nicht nur - wie Hunderte andere wissenschaftliche Theorien - von der "Welt da draußen“, sondern vor allem auch von uns selbst und von unserem Platz in dieser Welt. Den einen gilt sie obendrein als Überwinderin religiösen Aberglaubens, den anderen als neuer Zugang zu Gott und seinem Wirken in der Welt. Ferner sehen die einen in der Evolution eine unbezweifelbare Tatsache gleich der Schwerkraft oder dem Holocaust, die anderen aber eine - noch oder dauerhaft - unbewiesene Hypothese oder gar eine falsche Schöpfungslehre. Und während die meisten Streitfragen solcher Art nach wechselseitig akzeptierten Regeln ‚normaler Wissenschaft‘ geklärt werden, wird bei der Frage nach dem Woher unserer Spezies und Kultur die intellektuelle Zuständigkeit von Wissenschaft mitunter überhaupt bezweifelt. Anscheinend geht es schon um recht tiefe Schichten unserer Kultur und nicht nur der wissenschaftlichen, wenn - wie seit 150 Jahren - um die Evolutionstheorie gestritten wird. Wie sehen diese Schichten aus?

  14. The Ambiguous Dying Syndrome

    ERIC Educational Resources Information Center

    Bern-Klug, Mercedes

    2004-01-01

    More than one-half of the 2.4 million deaths that will occur in the United States in 2004 will be immediately preceded by a time in which the likelihood of dying can best be described as "ambiguous." Many people die without ever being considered "dying" or "at the end of life." These people may miss out on the…

  15. The Angry Dying Patient.

    PubMed

    Houston, Robert E.

    1999-02-01

    Over 25 years ago, Kubler-Ross identified anger as a predictable part of the dying process. When the dying patient becomes angry in the clinical setting, all types of communication become strained. Physicians can help the angry dying patient through this difficult time by using 10 rules of engagement. When physicians engage and empathize with these patients, they improve the patient's response to pain and they reduce patient suffering. When physicians educate patients on their normal responses to dying and enlist them in the process of family reconciliation, they can impact the end-of-life experience in a positive way.

  16. The Angry Dying Patient

    PubMed Central

    Houston, Robert E.

    1999-01-01

    Over 25 years ago, Kubler-Ross identified anger as a predictable part of the dying process. When the dying patient becomes angry in the clinical setting, all types of communication become strained. Physicians can help the angry dying patient through this difficult time by using 10 rules of engagement. When physicians engage and empathize with these patients, they improve the patient's response to pain and they reduce patient suffering. When physicians educate patients on their normal responses to dying and enlist them in the process of family reconciliation, they can impact the end-of-life experience in a positive way. PMID:15014699

  17. Tag retention, growth, and survival of red swamp crayfish marked with a visible implant tag

    USGS Publications Warehouse

    Isely, J.J.; Stockett, P.E.

    2001-01-01

    Eighty juvenile (means: 42.4 mm total length, 1.6 g) red swamp crayfish Procambarus clarkii were implanted with sequentially numbered visible implant tags and held in the laboratory. Tags were injected transversely into the musculature just beneath the exoskeleton of the third abdominal segment from the cephalothorax; tags were visible upon inspection. An additional 20 crayfish were left untagged and served as controls. After 150 d, tag retention was 80% and all tags were readable. No tagged crayfish died during the study, and no differences in total length or weight were detected between tagged and control crayfish. All individuals molted at least three times during the 150-d study, and some individuals molted up to six times, suggesting that most tags would be permanently retained. The readability in the field without specialized equipment makes the visible implant tag ideal for studies of crayfish ecology, management, and culture.

  18. A fully implantable pacemaker for the mouse: from battery to wireless power.

    PubMed

    Laughner, Jacob I; Marrus, Scott B; Zellmer, Erik R; Weinheimer, Carla J; MacEwan, Matthew R; Cui, Sophia X; Nerbonne, Jeanne M; Efimov, Igor R

    2013-01-01

    Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days) pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24) were implanted with endocardial, battery-powered devices (n = 14) and epicardial, wireless-powered devices (n = 10). Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1%) mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10%) mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice.

  19. A Fully Implantable Pacemaker for the Mouse: From Battery to Wireless Power

    PubMed Central

    Zellmer, Erik R.; Weinheimer, Carla J.; MacEwan, Matthew R.; Cui, Sophia X.; Nerbonne, Jeanne M.; Efimov, Igor R.

    2013-01-01

    Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days) pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24) were implanted with endocardial, battery-powered devices (n = 14) and epicardial, wireless-powered devices (n = 10). Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1%) mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10%) mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice. PMID:24194832

  20. Energy Saving Melting and Revert Reduction Technology (E-SMARRT): Development of Surface Engineered Coating Systems for Aluminum Pressure Die Casting Dies: Towards a 'Smart' Die Coating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dr. John J. Moore; Dr. Jianliang Lin,

    2012-07-31

    The main objective of this research program was to design and develop an optimal coating system that extends die life by minimizing premature die failure. In high-pressure aluminum die-casting, the die, core pins and inserts must withstand severe processing conditions. Many of the dies and tools in the industry are being coated to improve wear-resistance and decrease down-time for maintenance. However, thermal fatigue in metal itself can still be a major problem, especially since it often leads to catastrophic failure (i.e. die breakage) as opposed to a wear-based failure (parts begin to go out of tolerance). Tooling costs remain themore » largest portion of production costs for many of these parts, so the ability prevent catastrophic failures would be transformative for the manufacturing industry.The technology offers energy savings through reduced energy use in the die casting process from several factors, including increased life of the tools and dies, reuse of the dies and die components, reduction/elimination of lubricants, and reduced machine down time, and reduction of Al solder sticking on the die. The use of the optimized die coating system will also reduce environmental wastes and scrap parts. Current (2012) annual energy saving estimates, based on initial dissemination to the casting industry in 2010 and market penetration of 80% by 2020, is 3.1 trillion BTU's/year. The average annual estimate of CO2 reduction per year through 2020 is 0.63 Million Metric Tons of Carbon Equivalent (MM TCE).« less

  1. Zirconium, calcium, and strontium contents in magnesium based biodegradable alloys modulate the efficiency of implant-induced osseointegration

    PubMed Central

    Mushahary, Dolly; Sravanthi, Ragamouni; Li, Yuncang; Kumar, Mahesh J; Harishankar, Nemani; Hodgson, Peter D; Wen, Cuie; Pande, Gopal

    2013-01-01

    Development of new biodegradable implants and devices is necessary to meet the increasing needs of regenerative orthopedic procedures. An important consideration while formulating new implant materials is that they should physicochemically and biologically mimic bone-like properties. In earlier studies, we have developed and characterized magnesium based biodegradable alloys, in particular magnesium-zirconium (Mg-Zr) alloys. Here we have reported the biological properties of four Mg-Zr alloys containing different quantities of strontium or calcium. The alloys were implanted in small cavities made in femur bones of New Zealand White rabbits, and the quantitative and qualitative assessments of newly induced bone tissue were carried out. A total of 30 experimental animals, three for each implant type, were studied, and bone induction was assessed by histological, immunohistochemical and radiological methods; cavities in the femurs with no implants and observed for the same period of time were kept as controls. Our results showed that Mg-Zr alloys containing appropriate quantities of strontium were more efficient in inducing good quality mineralized bone than other alloys. Our results have been discussed in the context of physicochemical and biological properties of the alloys, and they could be very useful in determining the nature of future generations of biodegradable orthopedic implants. PMID:23976848

  2. Implant-supported Mandibular Overdentures in Very Old Adults

    PubMed Central

    Müller, F.; Duvernay, E.; Loup, A.; Vazquez, L.; Herrmann, F.R.; Schimmel, M.

    2013-01-01

    The purpose of this study was (1) to investigate denture satisfaction following the conversion of existing mandibular complete dentures to implant overdentures (IOD) in very old edentulous patients who depend on help for activities of daily living and (2) to evaluate secondary end points, such as functional, structural, nutritional, and patient-centered aspects. For this randomized clinical trial, 2 interforaminal short implants were placed in the intervention group (n = 16, 85.0 ± 6.19 yrs) to retain mandibular IODs; the control group (n = 18, 84.1 ± 5.55 yrs) received conventional relines. During the first year, no implant was lost; however, 2 patients died. IODs proved more stable, and participants in the intervention group demonstrated significantly higher denture satisfaction as well as an increased oral health–related quality of life compared to the control group. Maximum voluntary bite force improved significantly with IODs, yet the chewing efficiency was not different between groups. Masseter muscle thickness increased with IODs, mainly on the preferred chewing side. Body mass index decreased in both groups, but the decline tended to be smaller in the intervention group; blood markers and the Mini Nutritional Assessment did not confirm this tendency. These results indicate that edentulous patients who depend on help for activities of daily living may benefit from IODs even late in life (ClinicalTrial.gov NCT01928004). PMID:24158342

  3. [Thrombosis in vascular accesses for haemodialysis: rescue treatment using invasive vascular radiological techniques].

    PubMed

    García Medina, J; Lacasa Pérez, N; Muray Cases, S; Pérez Garrido, I; García Medina, V

    2009-01-01

    The purpose of this paper is to communicate our experience in the salvage of thrombosed haemodialysis vascular accesses using interventional radiology techniques. In the last four years, we have treated, by radiological means, 101 thrombosed haemodialysis vascular accesses. There were 44 autologous arteriovenous fistulas (43.56%) and 57 PTFE grafts (56.44%). There were 69 men (68.3%) and 32 women (31.7%). The mean age was 67.73 years (range 33-84). The mean vascular access age was 23.79 months (range 1-132). Manual catheter-directed aspiration was used. Fragmented, triturated or pushed the thrombus against the pulmonary circulation was avoided in all cases. 78 accesses were salvaged (77.2%). Autologous fistulas average and PTFE grafts success rate were 84.44% and 71.42% respectively. Angioplasty in one or more lesions after thromboaspiration was performed in all accesses, except six (5.9%). Metallic endoprostheses were implanted in 14 accesses (13.9%). Mean follow-up was 9 months (range 0-44). Primary patency was 42.3% +/- 5 at 6 months and 32% +/- 4 at one year. Autologous fistulas patency was better than PTFE grafts patency (p < or =0,05). Our results suggest thrombosed autologous arteriovenous fistulas salvage is better than PTFE grafts. This justifies interventional radiology techniques in these situations.

  4. Neighbour-die effect on the measurement of wafer-level flip-chip LED dies in production lines

    NASA Astrophysics Data System (ADS)

    Chen, Tengfei; Wan, Zirui; Li, Bin

    2017-11-01

    The light from the side surfaces of the test flip-chip light-emitting diode (FCLED) dies is reflected, refracted or absorbed by neighbour dies during the measurement of wafer-level FCLED dies in production lines. A notable measurement deviation is caused by the neighbour-die effect, which is not considered in current industry practice. In this paper, Monte Carlo ray-tracing simulations are used to study the measurement deviations caused by the neighbour-die effect and extension ratios of the film. The simulation results show that the maximal deviation of radiant flux impinging the photodiode can reach 5.5%, if the die is tested without any neighbour dies, or is surrounded by a set of neighbour dies at an extension ratio of 1.1. Moreover, the dependence between the measurement results and neighbour cases for different extension ratios is also investigated. Then, a modified calibration method is proposed and studied. The proposed technique can be used to improve the calibration and measurement accuracy of the test equipment used for measurement of wafer-level FCLED dies in production lines.

  5. Percutaneous Transcatheter One-Step Mechanical Aortic Disc Valve Prosthesis Implantation: A Preliminary Feasibility Study in Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sochman, Jan; Peregrin, Jan H.; Rocek, Miloslav

    Purpose. To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. Methods. The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z andmore » 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. Results. MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. Conclusion. The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.« less

  6. Clinical Outcome of Hydroxyapatite Coated, Bioactive Glass Coated, and Machined Ti6Al4V Threaded Dental Implant in Human Jaws: A Short-Term Comparative Study.

    PubMed

    Mistry, Surajit; Roy, Rajiv; Kundu, Biswanath; Datta, Someswar; Kumar, Manoj; Chanda, Abhijit; Kundu, Debabrata

    2016-04-01

    Growing aspect of endosseous implant research is focused on surface modification of dental implants for the purpose of improving osseointegration. The aim of this study was to evaluate and compare the clinical outcome (ie, osseointegration) of hydroxyapatite coated, bioactive glass coated and machined titanium alloy threaded dental implants in human jaw bone after implantation. One hundred twenty-six implants (45 hydroxyapatite coated, 41 bioactive glass coated, and 40 machined titanium implants) have been placed in incisor areas of 62 adult patients. Outcome was assessed up to 12 months after prosthetic rehabilitation using different clinical and radiological parameters. Surface roughness of failed implants was analyzed by laser profilometer. Hydroxyapatite and bioactive glass coating materials were nontoxic and biocompatible. Least marginal bone loss in radiograph, significantly higher (P < 0.05) interface radiodensity, and less interfacial gaps were observed in computed tomography with bioactive glass coated implants at anterior maxilla compared to other 2 types. Bioactive glass coated implants are equally safe and effective as hydroxyapatite coated and machined titanium implants in achieving osseointegration; therefore, can be effectively used as an alternative coating material for dental implants.

  7. Maxillary reconstruction to enable implant insertion: a retrospective study of 181 patients

    PubMed Central

    Ferri, Joël; Dujoncquoy, Jean-Pascal; Carneiro, José Mario; Raoul, Gwénael

    2008-01-01

    Background The purpose of the present study was to evaluate different types of maxillary pre-prosthetic surgery using autogenous bone graft and suggest a guideline for maxillary reconstruction to place implant. Methods 181 patients (125 females and 56 males), age range from 16 to 76 years old, were operated at the Maxillo-Facial Service of the Lille's 2 Universitary Hospital Center (Chairman Pr Joël Ferri). Different techniques were used, but always with autogenous bone grafting. 21 patients underwent a Lefort 1 procedure, 139 underwent sinus graft with or without vestibular onlay graft and 21 underwent onlay graft. This surgical procedure was made to allow the insertion of 685 implants. Results The patients were evaluated by clinical and radiological assessment. In the cases of Lefort 1, the rate of successful osteointegration was higher when the implants were placed in the second part of a two stages procedure: 92%, against 81% for one stage. In cases of sinus lift procedure, the rate of implant success was 98%. The infection rate was 3.5%. There was no significant resorption and the type of prosthesis used was a denture retained by a bar or fixed bridge. In cases of onlay graft, the implant insertion success was 97% and there was no infection. The amount of resorption was more significant in the pre-maxilla than in the other areas and the type of prosthesis used was fixed dentures. Conclusion These observations demonstrate that: the aetiology of the bone defect indicate the type and number of the surgical procedures to re-established good jaws relationship and give the bone conditions to implant insertion successful. Clinical Relevance A guideline for surgical decision in the maxillary reconstruction for oral rehabilitation by implants may help to prevent failures of osseous resorption disorders and to foresee the investment of the bone in quality and necessary quantity. PMID:19087352

  8. [Pigment dispersion and Artisan implants: crystalline lens rise as a safety criterion].

    PubMed

    Baikoff, G; Bourgeon, G; Jodai, H Jitsuo; Fontaine, A; Vieira Lellis, F; Trinquet, L

    2005-06-01

    To validate the theoretical notion of a crystalline lens rise as a safety criterion for ARTISAN implants in order to prevent the development of pigment dispersion in the implanted eye. Crystalline lens rise is defined by the distance between the crystalline lens's anterior pole and the horizontal plane joining the opposite iridocorneal recesses. We analyzed the biometric measurements of 87 eyes with an Artisan implant. A comparative analysis of the crystalline lens rise was carried out on the nine eyes having developed pigment dispersion and 78 eyes with no problems. Among the modern anterior segment imaging devices (Artemis, Scheimpflug photography, optical coherence tomography, radiology exploration, magnetic resonance imaging, TDM), an anterior chamber optical coherence tomography (AC-OCT) prototype was used. This working hypothesis was confirmed by this study: the crystalline lens rise must be considered as a new safety criterion for implanting Artisan phakic lenses. Indeed, the higher the crystalline lens's rise, the greater the risk of developing pigment dispersion in the pupil area. This complication is more frequent in hyperopes than in myopes. We can consider that there is little or no risk of pigment dispersion if the rise is below 600 microm; however, at 600 microm or greater, there is a 67% rate of pupillary pigment dispersion. In certain cases, when the implant was loosely fixed, there was no traction on the iris root. This is a complication that can be avoided or delayed. The crystalline lens rise must be part of new safety criteria to be taken into consideration when inserting an Artisan implant. This notion must also be applied to other types of phakic implants. The distance remaining between the crystalline lens rise and a 600-micromm theoretical safety level allows one to calculate a safety time interval.

  9. Dental implant imaging: TeraRecon's Dental 3D Cone Beam Computed Tomography System.

    PubMed

    Garg, Arun K

    2007-06-01

    Early in the development of implant technology, conventional dental imaging techniques were limited for evaluating the patient for implant surgery. During the treatment-planning phase, the recipient bed is routinely assessed by visual examination and palpation, as well as by periapical and panoramic radiology. These two imaging modalities provide a two-dimensional image of the mesiodistal and occlusoapical dimensions of the edentulous regions where the implants might be placed. When adequate occlusoapical bone height is available for endosteal implants, the buccolingual width and angulation of the available bone are the most important criteria for implant selection and success. However, neither buccolingual width nor angulation can be visualized on most traditional radiographs. Although clinical examination and traditional radiographs may be adequate for patients with wide residual ridges that exhibit sufficient bone crestal to the mandibular nerve and maxillary sinus, these methods do not allow for the precise measurement of the buccolingual dimension of the bone or assessment of the location of unanticipated undercuts. Because of these concerns, it is necessary to view the recipient site in a plane through the arch of the maxilla or mandible in the region of the proposed implants. Implant surgeons soon recognized that, for the optimum placement of implants, cross-sectional views of the maxilla and mandible are the ideal means for providing necessary preoperative information. For complex cases where multiple implants are required or where anatomical measurements are crucial, but also increasingly for more routine cases, more and more clinicians are recommending CT scan imaging procedure such as that offered by TeraRecon's Dental CBCT system. Because of its ability to reconstruct a fully three-dimensional model of the maxilla and mandible, CBCT provides a highly sophisticated format for precisely defining the jaw structure and locating critical anatomic structures

  10. Peri-implantitis.

    PubMed

    Schwarz, Frank; Derks, Jan; Monje, Alberto; Wang, Hom-Lay

    2018-06-01

    This narrative review provides an evidence-based overview on peri-implantitis for the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions. A literature review was conducted addressing the following topics: 1) definition of peri-implantitis; 2) conversion from peri-implant mucositis to peri-implantitis, 3) onset and pattern of disease progression, 4) characteristics of peri-implantitis, 5) risk factors/indicators for peri-implantitis, and 6) progressive crestal bone loss in the absence of soft tissue inflammation. 1)Peri-implantitis is a pathological condition occurring in tissues around dental implants, characterized by inflammation in the peri-implant connective tissue and progressive loss of supporting bone. 2)The histopathologic and clinical conditions leading to the conversion from peri-implant mucositis to peri-implantitis are not completely understood. 3)The onset of peri-implantitis may occur early during follow-up and the disease progresses in a non-linear and accelerating pattern. 4a)Peri-implantitis sites exhibit clinical signs of inflammation and increased probing depths compared to baseline measurements. 4b)At the histologic level, compared to periodontitis sites, peri-implantitis sites often have larger inflammatory lesions. 4c)Surgical entry at peri-implantitis sites often reveals a circumferential pattern of bone loss. 5a)There is strong evidence that there is an increased risk of developing peri-implantitis in patients who have a history of chronic periodontitis, poor plaque control skills, and no regular maintenance care after implant therapy. Data identifying "smoking" and "diabetes" as potential risk factors/indicators for peri-implantitis are inconclusive. 5b)There is some limited evidence linking peri-implantitis to other factors such as: post-restorative presence of submucosal cement, lack of peri-implant keratinized mucosa and positioning of implants that make it difficult to perform oral hygiene

  11. Extrusion die and method

    DOEpatents

    Lipp, G. Daniel

    1994-04-26

    A method and die apparatus for manufacturing a honeycomb body of rhombic cell cross-section by extrusion through an extrusion die of triangular cell discharge slot configuration, the die incorporating feedholes at selected slot intersections only, such that slot segments communicating directly with the feedholes discharge web material and slot segments not so connected do not discharge web material, whereby a rhombic cell cross-section in the extruded body is provided.

  12. Neurotrophic Electrode: Method of assembly and implantation into human motor speech cortex

    PubMed Central

    Bartels, Jess; Andreasen, Dinal; Ehirim, Princewill; Mao, Hui; Seibert, Steven; Wright, E Joe; Kennedy, Philip

    2008-01-01

    The Neurotrophic Electrode (NE) is designed for longevity and stability of recorded signals. To achieve this aim it induces neurites to grow through its glass tip, thus anchoring it in neuropil. The glass tip contains insulated gold wires for recording the activity of the myelinated neurites that grow into the tip. Neural signals inside the tip are electrically insulated from surrounding neural activity by the glass. The most recent version of the electrode has four wires inside its tip to maximize the number of discriminable signals recorded from ingrown neurites, and has a miniature connector. Flexible coiled, insulated gold wires connect to electronics on the skull that remain subcutaneous. The implanted electronics consist of differential amplifiers, FM transmitters, and a sine wave at power up for tuning and calibration. Inclusion criteria for selecting locked-in subjects include medical stability, normal cognition, and strong caregiver support. The implant target is localized via an fMRI-naming task. Final localization at surgery is achieved by 3D stereotaxic localization. During recording, implanted electronics are powered by magnetic induction across an air gap. Coiled antennas placed on the scalp over the implanted transmitters receive the amplified FM transmitter outputs. Data is processed as described elsewhere where stability and longevity issues are addressed. Five subjects have been successfully implanted with the NE. Recorded signals persisted for over four years in two subjects who died from underlying illnesses, and continue for over three years in our present subject. PMID:18672003

  13. Carcinosarcoma of the Extrahepatic Bile Duct Presenting with Stone-like Radiological Findings.

    PubMed

    Kumei, Shinsuke; Onishi, Yutaka; Ogura, Takeshi; Kusumoto, Chosei; Matsuno, Yasuko; Nishigami, Takashi; Maeda, Mitsuo; Harada, Masaru

    2015-01-01

    A 73-year-old woman was referred to our hospital due to epigastralgia and jaundice. The radiological findings showed a stone-like tumor in the extrahepatic bile duct. The patient was initially thought to have adenocarcinoma of the bile duct based on the findings of a pathological examination of the bile duct biopsy specimen and underwent pancreaticoduodenectomy; the final diagnosis of the lesion was so-called carcinosarcoma of the extrahepatic bile duct. She died of liver metastasis six months after the surgery. This case suggests that surgical resection is not adequate for achieving a radical cure, and the optimal treatment for extrahepatic bile duct carcinosarcoma should be established immediately.

  14. Machine Learning and Radiology

    PubMed Central

    Wang, Shijun; Summers, Ronald M.

    2012-01-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. PMID:22465077

  15. Histological and radiological evaluation of sintered and non-sintered deproteinized bovine bone substitute materials in sinus augmentation procedures. A prospective, randomized-controlled, clinical multicenter study.

    PubMed

    Fienitz, Tim; Moses, Ofer; Klemm, Christoph; Happe, Arndt; Ferrari, Daniel; Kreppel, Matthias; Ormianer, Zeev; Gal, Moti; Rothamel, Daniel

    2017-04-01

    The objective of this study is to histologically and radiologically compare a sintered and a non-sintered bovine bone substitute material in sinus augmentation procedures. Thirty-three patients were included in the clinically controlled randomized multicentre study resulting in a total of 44 treated sinuses. After lateral approach, sinuses were filled with either a sintered (SBM, Alpha Bio's Graft ® ) or a non-sintered (NSBM, Bio Oss ® ) deproteinized bovine bone substitute material. The augmentation sites were radiologically assessed before and immediately after the augmentation procedure as well as prior to implant placement. Bone trephine biopsies for histological analysis were harvested 6 months after augmentation whilst preparing the osteotomies for implant placement. Healing was uneventful in all patients. After 6 months, radiological evaluation of 43 sinuses revealed a residual augmentation height of 94.65 % (±2.74) for SBM and 95.76 % (±2.15) for NSBM. One patient left the study for personal reasons. Histological analysis revealed a percentage of new bone of 29.71 % (±13.67) for SBM and 30.57 % (±16.07) for NSBM. Residual bone substitute material averaged at 40.68 % (±16.32) for SBM compared to 43.43 % (±19.07) for NSBM. All differences between the groups were not statistically significant (p > 0.05, Student's t test). Both xenogeneic bone substitute materials showed comparable results regarding new bone formation and radiological height changes in external sinus grafting procedures. Both bone substitute materials allow for a predictable new bone formation following sinus augmentation procedures.

  16. Long-term Survival of Straumann Dental Implants with TPS Surfaces: A Retrospective Study with a Follow-up of 12 to 23 Years.

    PubMed

    Becker, Stephan T; Beck-Broichsitter, Benedicta E; Rossmann, Christian M; Behrens, Eleonore; Jochens, Arne; Wiltfang, Jörg

    2016-06-01

    The aim of this study was to evaluate the long-term dental implant survival rates of Straumann dental implants in a university hospital environment over 12 to 23 years. A total of 388 Straumann dental implants with titanium-sprayed surfaces (TPS) were inserted in 92 patients between 1988 and 1999 in the Department of Oral and Maxillofacial Surgery of the University Hospital Schleswig-Holstein in Kiel, and they were reevaluated with standardized clinical and radiological exams. Kaplan-Meier analyses were performed for individual factors. Cox proportional hazard regression analysis was used to detect the factors influencing long-term implant failure. The long-term implant survival rate was 88.03% after an observation time of 12.2 to 23.5 years. Cox regression revealed statistically significant influences of the International Team for Implantology (ITI) implantation type (p = .00354) and tobacco smoking (p = .01264) on implant failure. A proportion 82.8% of the patients with implant losses had a medical history of periodontitis. Peri-implantitis was diagnosed in 9.7% of the remaining implants in the long-term survey. This study emphasized the long-term rehabilitation capabilities of Straumann dental implants in complex cases. The survival rates after several years constitute important information for patients, as well as for clinicians, in deciding about different concepts of tooth replacement. Patient-related and technical factors - determined before implant placement - could help to predict the risk of implant loss. © 2015 Wiley Periodicals, Inc.

  17. Clinical Risk Stratification for Primary Prevention Implantable Cardioverter Defibrillators

    PubMed Central

    Hardy, Judy; Yee, Raymond; Healey, Jeffrey S.; Birnie, David; Simpson, Christopher S.; Crystal, Eugene; Mangat, Iqwal; Nanthakumar, Kumaraswamy; Wang, Xuesong; Krahn, Andrew D.; Dorian, Paul; Austin, Peter C.; Tu, Jack V.

    2015-01-01

    Background— A conceptualized model may be useful for understanding risk stratification of primary prevention implantable cardioverter defibrillators considering the competing risks of appropriate implantable cardioverter defibrillator shock versus mortality. Methods and Results— In a prospective, multicenter, population-based cohort with left ventricular ejection fraction ≤35% referred for primary prevention implantable cardioverter defibrillator, we developed dual risk stratification models to determine the competing risks of appropriate defibrillator shock versus mortality using a Fine-Gray subdistribution hazard model. Among 7020 patients referred, 3445 underwent defibrillator implant (79.7% men, median, 66 years [25th, 75th: 58–73]). During 5918 person-years of follow-up, appropriate shock occurred in 204 patients (3.6 shocks/100 person-years) and 292 died (4.9 deaths/100 person-years). Competing risk predictors of appropriate shock included nonsustained ventricular tachycardia, atrial fibrillation, serum creatinine concentration, digoxin or amiodarone use, and QRS duration near 130-ms peak. One-year cumulative incidence of appropriate shock was 0.9% in the lowest risk category, and 1.7%, 2.5%, 4.9%, and 9.3% in low, intermediate, high, and highest risk groups, respectively. Hazard ratios for appropriate shock ranged from 4.04 to 7.79 in the highest 3 deciles (all P≤0.001 versus lowest risk). Cumulative incidence of 1-year death was 0.6%, 1.9%, 3.3%, 6.2%, and 17.7% in lowest, low, intermediate, high, and highest risk groups, respectively. Mortality hazard ratios ranged from 11.48 to 36.22 in the highest 3 deciles (all P<0.001 versus lowest risk). Conclusions— Simultaneous estimation of risks of appropriate shock and mortality can be performed using clinical variables, providing a potential framework for identification of patients who are unlikely to benefit from prophylactic implantable cardioverter defibrillator. PMID:26224792

  18. Automated classification of radiology reports to facilitate retrospective study in radiology.

    PubMed

    Zhou, Yihua; Amundson, Per K; Yu, Fang; Kessler, Marcus M; Benzinger, Tammie L S; Wippold, Franz J

    2014-12-01

    Retrospective research is an import tool in radiology. Identifying imaging examinations appropriate for a given research question from the unstructured radiology reports is extremely useful, but labor-intensive. Using the machine learning text-mining methods implemented in LingPipe [1], we evaluated the performance of the dynamic language model (DLM) and the Naïve Bayesian (NB) classifiers in classifying radiology reports to facilitate identification of radiological examinations for research projects. The training dataset consisted of 14,325 sentences from 11,432 radiology reports randomly selected from a database of 5,104,594 reports in all disciplines of radiology. The training sentences were categorized manually into six categories (Positive, Differential, Post Treatment, Negative, Normal, and History). A 10-fold cross-validation [2] was used to evaluate the performance of the models, which were tested in classification of radiology reports for cases of sellar or suprasellar masses and colloid cysts. The average accuracies for the DLM and NB classifiers were 88.5% with 95% confidence interval (CI) of 1.9% and 85.9% with 95% CI of 2.0%, respectively. The DLM performed slightly better and was used to classify 1,397 radiology reports containing the keywords "sellar or suprasellar mass", or "colloid cyst". The DLM model produced an accuracy of 88.2% with 95% CI of 2.1% for 959 reports that contain "sellar or suprasellar mass" and an accuracy of 86.3% with 95% CI of 2.5% for 437 reports of "colloid cyst". We conclude that automated classification of radiology reports using machine learning techniques can effectively facilitate the identification of cases suitable for retrospective research.

  19. Pediatric radiology malpractice claims - characteristics and comparison to adult radiology claims.

    PubMed

    Breen, Micheál A; Dwyer, Kathy; Yu-Moe, Winnie; Taylor, George A

    2017-06-01

    Medical malpractice is the primary method by which people who believe they have suffered an injury in the course of medical care seek compensation in the United States and Canada. An increasing body of research demonstrates that failure to correctly diagnose is the most common allegation made in malpractice claims against radiologists. Since the 1994 survey by the Society of Chairmen of Radiology in Children's Hospitals (SCORCH), no other published studies have specifically examined the frequency or clinical context of malpractice claims against pediatric radiologists or arising from pediatric imaging interpretation. We hypothesize that the frequency, character and outcome of malpractice claims made against pediatric radiologists differ from those seen in general radiology practice. We searched the Controlled Risk Insurance Co. (CRICO) Strategies' Comparative Benchmarking System (CBS), a private repository of approximately 350,000 open and closed medical malpractice claims in the United States, for claims related to pediatric radiology. We further queried these cases for the major allegation, the clinical environment in which the claim arose, the clinical severity of the alleged injury, indemnity paid (if payment was made), primary imaging modality involved (if applicable) and primary International Classification of Diseases, 9th revision (ICD-9) diagnosis underlying the claim. There were a total of 27,056 fully coded claims of medical malpractice in the CBS database in the 5-year period between Jan. 1, 2010, and Dec. 31, 2014. Of these, 1,472 cases (5.4%) involved patients younger than 18 years. Radiology was the primary service responsible for 71/1,472 (4.8%) pediatric cases. There were statistically significant differences in average payout for pediatric radiology claims ($314,671) compared to adult radiology claims ($174,033). The allegations were primarily diagnosis-related in 70% of pediatric radiology claims. The most common imaging modality implicated in

  20. Two-Implant-Supported Mandibular Overdentures: Do Clinical Denture Quality and Inter-Implant Distance Affect Patient Satisfaction?

    PubMed

    Alfadda, Sara A; Al Amri, Mohammad D; Al-Ohali, Amal; Al-Hakami, Arwa; Al-Madhi, Noura

    To investigate the following three null hypotheses in patients rehabilitated with a mandibular overdenture supported by two unsplinted implants: (1) patient satisfaction is not related to the clinical quality of the dentures; (2) inter-implant distance (IID) has no effect on the clinical quality of the dentures; and (3) IID does not influence patient satisfaction. Forty edentulous patients who were rehabilitated with a two-implant-supported mandibular overdenture participated in the study. Independent investigators evaluated the dentures on the basis of five clinical criteria using the validated Denture Quality Evaluation Form, and the patients completed the validated Denture Satisfaction Scale. Irreversible hydrocolloid impressions of the mandible were made and poured immediately in die stone. The IID was measured by adapting an orthodontic wire to the mandibular alveolar ridge crest, extending from the center of one implant to the center of the other. Spearman correlation analyses were used to identify possible correlations, with a significance level set at P < .05. The clinicians' overall mean rating of the clinical quality of the dentures was 91.5% (standard deviation 6.27%). The stability of the mandibular overdenture and of the maxillary conventional complete denture was significantly related to satisfaction (r = 0.389 and r = 0.44, respectively). Significant associations were found between the mandibular stability items and satisfaction with both maxillary and mandibular dentures. The stability of the maxillary denture was significantly associated with patient satisfaction with mandibular denture retention, stability, and comfort. None of the 12 denture satisfaction items were significantly associated with IID. Similarly, IID did not have an effect on the quality of either denture in terms of retention, stability, or occlusion. Denture stability was the feature that had the most influence on patient satisfaction with the mandibular overdenture and with the

  1. Psychotherapy with Older Dying Persons.

    ERIC Educational Resources Information Center

    Dye, Carol J.

    Psychotherapy with older dying patients can lead to problems of countertransference for the clinician. Working with dying patients requires flexibility to adapt basic therapeutics to the institutional setting. Goals of psychotherapy must be reconceptualized for dying clients. The problems of countertransference arise because clinicians themselves…

  2. Machine learning and radiology.

    PubMed

    Wang, Shijun; Summers, Ronald M

    2012-07-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. Copyright © 2012. Published by Elsevier B.V.

  3. Radiology in Medical Education: A Pediatric Radiology Elective as a Template for Other Radiology Courses.

    PubMed

    Hilmes, Melissa A; Hyatt, Eddie; Penrod, Cody H; Fleming, Amy E; Singh, Sudha P

    2016-03-01

    Traditionally, the pediatric radiology elective for medical students and pediatric residents constituted a morning teaching session focused mainly on radiography and fluoroscopy. A more structured elective was desired to broaden the exposure to more imaging modalities, create a more uniform educational experience, and include assessment tools. In 2012, an introductory e-mail and formal syllabus, including required reading assignments, were sent to participants before the start date. A rotating weekly schedule was expanded to include cross-sectional imaging (ultrasound, CT, MR) and nuclear medicine. The schedule could accommodate specific goals of the pediatric resident or medical student, as requested. Starting in 2013, an online pre-test and post-test were developed, as well as an online end-of-rotation survey specific to the pediatric radiology elective. Taking the Image Gently pledge was required. A scavenger hunt tool, cue cards, and electronic modules were added. Pre-test and post-test scores, averaged over 2 years, showed improvement in radiology knowledge, with scores increasing by 27% for medical students and 21% for pediatric residents. Surveys at the end of the elective were overwhelmingly positive, with constructive criticism and complimentary comments. We have successfully created an elective experience in radiology that dedicates time to education while preserving the workflow of radiologists. We have developed tools to provide a customized experience with many self-directed learning opportunities. Our tools and techniques are easily translatable to a general or adult radiology elective. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  4. [Possibilities of follow-up imaging after implantation of a carbon fiber-reinforced hip prosthesis].

    PubMed

    Krüger, T; Alter, C; Reichel, H; Birke, A; Hein, W; Spielmann, R P

    1998-03-01

    There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. The small sclerotic interface is quite different in comparison to so called "Reactive Lines". In one case of aseptic loosening there was an interposition of soft tissue between prosthesis and bone in MRT and CT. CFRP inaugurates new diagnostic possibilities in aseptic loosening of hip prosthesis and in tumour surgery too.

  5. Pultrusion Die Assembly

    NASA Technical Reports Server (NTRS)

    Wilson, Maywood L. (Inventor); Johnson, Gary S. (Inventor); Frye, Mark W. (Inventor); Stanfield, Clarence E. (Inventor)

    1988-01-01

    This invention relates generally to pultrusion die assemblies, and more particularly, to a pultrusion die assembly which incorporates a plurality of functions in order to produce a continuous, thin composite fiber reinforced thermoplastic material. The invention is useful for making high performance thermoplastic composite materials in sheets which can be coiled on a spool and stored for further processing.

  6. Biomechanical behavior of 2-implant-and single-implant-retained mandibular overdentures with conventional or mini implants.

    PubMed

    Pisani, Marina Xavier; Presotto, Anna Gabriella Camacho; Mesquita, Marcelo Ferraz; Barão, Valentim Adelino Ricardo; Kemmoku, Daniel Takanori; Del Bel Cury, Altair Antoninha

    2018-04-24

    The use of single or mini dental implants to retain mandibular overdentures is still questionable. The purpose of this finite element analysis (FEA) study was to investigate the biomechanical behavior of 2- and single-implant-retained mandibular overdentures with conventional or mini implants. Four 3-dimensional (3D) finite element models were constructed with the following designs of mandibular overdentures: 2 (group 2-C) and single (group 1-C) conventional external hexagon implants with ball or O-ring attachment and 2 (group 2-M) and single (group 1-M) 1-piece mini implants. A 150-N axial load was applied bilaterally and simultaneously on the first molar. Overdenture displacement, von Mises equivalent stress (implants and/or prosthetic components), and maximum principal stresses (peri-implant bone) were recorded numerically and then color-coded and compared among the groups. The overdenture displacement (in mm) was higher for the 1-M (0.16) and 2-M (0.17) groups when compared with 1-C (0.09) and 2-C (0.08). Irrespective of the type of implant, the single-implant groups presented higher values of stress (in MPa) on the implants than did the 2-implant groups (1-C=52.53; 1-M=2.95; 2-C=34.66; 2-M=2.37), ball attachment (1-C=201.33; 2-C=159.06), housing or O-ring (1-C=125.01; 1-M=1.96; 2-C=88.84; 2-M=1.27), and peri-implant cortical bone (1-C=19.37; 1-M=1.47; 2-C=15.70; 2-M=1.06). The mini implant overdentures presented lower stress values on the implants, housing or O-ring, and peri-implant bone than did the conventional implant overdentures, regardless of the number of implants. The 2-implant-retained overdentures exhibited lower stresses than the single- implant-retained overdentures, irrespective of the type of implant. The mini implants demonstrated higher overdenture displacement and lower stresses than did conventional implant overdentures for single- and 2-implant-retained overdentures. Copyright © 2018 Editorial Council for the Journal of Prosthetic

  7. Machinery-related deaths: relevance of workplace investigation and antemortem radiological data in reconstructing the fatality.

    PubMed

    Cecchetto, Giovanni; Viel, Guido; De Lotto, Federica; Manara, Renzo; Montisci, Massimo; Zancaner, Silvano; Ferrara, S Davide

    2010-05-01

    Machinery-related fatalities are one of the leading causes of traumatic occupational deaths. In our report, we present the case of a 40-year-old male who suffered a severe head trauma while working in a cut-foam industry and died despite an early craniectomy. The radiological reconstruction of the skull based on preoperative computed tomography scans disclosed a large depressed conical fracture of the left parietal bone. The 3D-reconstruction of the work area, combined with a fit-matching analysis between the machinery and the depressed skull fracture allowed us to conclude that the head was crushed between the sliding bar of the cutting device and the metallic protuberance on the opposite side. The case underlines the importance of a detailed workplace investigation and of a thorough evaluation of all circumstantial, clinical, radiological, and autopsy data in the reconstruction of machinery-related fatalities to identify any possible legal responsibilities of the worker and/or the employer.

  8. Outcomes of endo-radiological approach to management of bile leakage after right lobe living donor liver transplantation.

    PubMed

    Chok, Kenneth S H; Chan, Albert C Y; Sharr, William W; Cheung, Tan To; Fung, James Y Y; Chan, See Ching; Lo, Chung Mau

    2016-01-01

    Bile leakage is a major complication after right lobe living donor liver transplantation (RLDLT). It can result in significant morbidities and, occasionally, mortalities. Endo-radiology is a non-surgical means that has been used to manage this complication. This study reviews the outcomes of the endo-radiological approach to the management of bile leakage after RLDLT with duct-to-duct anastomosis (DDA) at a high-volume center. A retrospective study was conducted on all adult patients who received RLDLT at our center between January 2001 and December 2013. There were 496 RLDLTs performed during the study period. Only patients who had DDA as the only bile duct reconstruction method were included in the study. Twelve (3.7%) out of the 328 study subjects developed bile leakage after RLDLT. Six out of these 12 patients were successfully treated with the endo-radiological approach without the need for laparotomy. They had endoscopic retrograde cholangiography with stenting followed by percutaneous drainage of biloma. One of the 12 patients died from recurrence of hepatocellular carcinoma 37 months after transplantation. The remaining 11 patients are all alive. The endo-radiological approach should be the first-line management for bile leakage for selected patients with DDA as the bile duct reconstruction method. © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  9. Histological Evaluation of a Self-Expanding Stent-Graft 23 Months After Implantation in the Superficial Femoral Artery.

    PubMed

    Ishihara, Takayuki; Iida, Osamu; Inoue, Katsumi; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Sunaga, Akihiro; Mano, Toshiaki; Uematsu, Masaaki

    2017-10-01

    To report histological examination of a Viabahn stent-graft implanted in the superficial femoral artery (SFA) for nearly 2 years. A 78-year-old man with peripheral artery disease was treated successfully with a 6.0×250-mm Viabahn self-expanding stent-graft in the right SFA, relieving his lower limb claudication. The patient died suddenly due to acute myocardial infarction 23 months later. Histological evaluation of the stent-graft implantation site revealed moderate neointimal proliferation at both proximal and distal edges of the device. In the middle part of the stent, significant macrophages and multinucleated foreign body giant cells had accumulated, although the stent was entirely patent. Furthermore, no endothelial cell coverage was found. Judging from these features, it might be necessary to continue dual antiplatelet therapy after stent-graft implantation over the long term to prevent thrombosis and subsequent restenosis or reocclusion.

  10. Socioeconomic trends in radiology.

    PubMed

    Barneveld Binkhuysen, F H

    1998-01-01

    For radiology the socioeconomic environment is a topic of increasing importance. In addition to the well-known important scientific developments in radiology such as interventional MRI, several other major trends can be recognized: (1) changes in the delivery of health care, in which all kinds of managed care are developing and will influence the practice of radiology, and (2) the process of computerization and digitization. The socioeconomic environment of radiology will be transformed by the developments in managed care, teleradiology and the integration of information systems. If radiologists want to manage future radiology departments they must have an understanding of the changes in the fields of economics and politics that are taking place and that will increasingly influence radiology. Some important and recognizable aspects of these changes will be described here.

  11. Defining quality in radiology.

    PubMed

    Blackmore, C Craig

    2007-04-01

    The introduction of pay for performance in medicine represents an opportunity for radiologists to define quality in radiology. Radiology quality can be defined on the basis of the production model that currently drives reimbursement, codifying the role of radiologists as being limited to the production of timely and accurate radiology reports produced in conditions of maximum patient safety and communicated in a timely manner. Alternately, quality in radiology can also encompass the professional role of radiologists as diagnostic imaging specialists responsible for the appropriate use, selection, interpretation, and application of imaging. Although potentially challenging to implement, the professional model for radiology quality is a comprehensive assessment of the ways in which radiologists add value to patient care. This essay is a discussion of the definition of radiology quality and the implications of that definition.

  12. Radiological controls integrated into design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kindred, G.W.

    1995-03-01

    Radiological controls are required by law in the design of commercial nuclear power reactor facilities. These controls can be relatively minor or significant, relative to cost. To ensure that radiological controls are designed into a project, the health physicist (radiological engineer) must be involved from the beginning. This is especially true regarding keeping costs down. For every radiological engineer at a nuclear power plant there must be fifty engineers of other disciplines. The radiological engineer cannot be an expert on every discipline of engineering. However, he must be knowledgeable to the degree of how a design will impact the facilitymore » from a radiological perspective. This paper will address how to effectively perform radiological analyses with the goal of radiological controls integrated into the design package.« less

  13. Short dental implants: an emerging concept in implant treatment.

    PubMed

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  14. Implantation of a new enteral stent in obstructive colorectal cancer using interventional radiology in patients over 70 years of age.

    PubMed

    Miłek, Tomasz; Ciostek, Piotr

    2015-07-01

    Colorectal cancer is the second leading cause of death due to cancer in Poland. The traditional approach to treat patients included a surgical procedure. Irrespective of the surgical method being used, surgical treatment of malignant colorectal obstruction is associated with prolonged hospitalisation, and the postoperative mortality rate is approximately 5-11%. Due to these problems, more interest has been shown in less invasive methods. Prosthesis implantation is a leading endoscopic method used currently in palliative or preoperative treatment. To compare the results of implantation of traditional stents with the results of implantation of an own stent using minimally invasive methods. Left-sided colon obstruction due to cancer was an indication for transplantation. All patients were aged over 70 years and had serious concomitant diseases. The control group included 50 patients with colorectal cancer who received traditional stents in the period 2009-2011. Our stent covers only the internal length of a tumour. It is not equipped with anti-migration flares. To minimize the risk of migration it has a system of hooks that are responsible for permanent anchorage of the stent within the tumour mass. Implantation technical and clinical success defined as effective decompression of intestinal obstruction was 100% in both groups. There were 2 cases of stent migration in the control group. It is possible to achieve a secure surgical anastomosis after intestinal decompression. Stent implantation is fast and safe thanks to the positioning system that was used. The use of labelled hooks is a secure anti-migration solution.

  15. Number of implants for mandibular implant overdentures: a systematic review

    PubMed Central

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  16. Cochlear Implants.

    ERIC Educational Resources Information Center

    Clark, Catherine; Scott, Larry

    This brochure explains what a cochlear implant is, lists the types of individuals with deafness who may be helped by a cochlear implant, describes the process of evaluating people for cochlear implants, discusses the surgical process for implanting the aid, traces the path of sound through the cochlear implant to the brain, notes the costs of…

  17. Rupture of poly implant prothèse silicone breast implants: an implant retrieval study.

    PubMed

    Swarts, Eric; Kop, Alan M; Nilasaroya, Anastasia; Keogh, Catherine V; Cooper, Timothy

    2013-04-01

    Poly Implant Prothèse implants were recalled in Australia in April of 2010 following concerns of higher than expected rupture rates and the use of unauthorized industrial grade silicone as a filler material. Although subsequent investigations found that the gel filler material does not pose a threat to human health, the important question of what caused a relatively modern breast implant to have such a poor outcome compared with contemporary silicone breast implants is yet to be addressed. From a cohort of 27 patients, 19 ruptured Poly Implant Prothèse breast implants were subjected to a range of mechanical tests and microscopic/macroscopic investigations to evaluate possible changes in properties as a result of implantation. New Poly Implant Prothèse implants were used as controls. All samples, explanted and controls, complied with the requirements for shell integrity as specified in the International Organization for Standardization 14607. Compression testing revealed rupture rates similar to those reported in the literature. Shell thickness was highly variable, with most shells having regions below the minimum thickness of 0.57 mm that was specified by the manufacturer. Potential regions of stress concentration were observed on the smooth inner surfaces and outer textured surfaces. The high incidence of Poly Implant Prothèse shell rupture is most likely a result of inadequate quality control, with contributory factors being shell thickness variation and manufacturing defects on both inner and outer surfaces of the shell. No evidence of shell degradation with implantation time was determined.

  18. CT-Guided Radioactive {sup 125}I Seed Implantation Therapy of Symptomatic Retroperitoneal Lymph Node Metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zhongmin, E-mail: wzm0722@hotmail.com; Lu, Jian; Gong, Ju

    2013-04-12

    PurposeThis study explored the clinical efficacy of CT-guided radioactive {sup 125}I seed implantation in treating patients with symptomatic retroperitoneal lymph node metastases.MethodsTwenty-five patients with pathologically confirmed malignant tumors received CT-guided radioactive {sup 125}I seed implantation to treat metastatic lymph nodes. The diameter of the metastatic lymph nodes ranged from 1.5 to 4.5 cm. Treatment planning system (TPS) was used to reconstruct the three-dimensional image of the tumor and then calculate the corresponding quantity and distribution of {sup 125}I seeds.ResultsFollow-up period for this group of patients was 2–30 months, and median time was 16 months. Symptoms of refractory pain were significantly resolved postimplantationmore » (P < 0.05), and Karnofsky score rose dramatically (P < 0.05). Most patients reported pain relief 2–5 days after treatment. Follow-up imaging studies were performed 2 months later, which revealed CR in 7 patients, PR in 13 patients, SD in 3 patients, and PD in 2 patients. The overall effective rate (CR + PR) was 80 %. Median survival time was 25.5 months. Seven patients died of recurrent tumor; 16 patients died of multiorgan failure or other metastases. Two patients survived after 30 months follow-up. Two patients reported localized skin erythema 1 week postimplantation, which disappeared after topical treatment.ConclusionsCT-guided radioactive {sup 125}I seed implantation, which showed good palliative pain relief with acceptable short-term effects, has proved in our study to be a new, safe, effective, and relatively uncomplicated treatment option for symptomatic retroperitoneal metastatic lymph nodes.« less

  19. Mitral valve repair in dogs using an ePTFE chordal implantation device: a pilot study.

    PubMed

    Borgarelli, M; Lanz, O; Pavlisko, N; Abbott, J A; Menciotti, G; Aherne, M; Lahmers, S M; Lahmers, K K; Gammie, J S

    2017-06-01

    Mitral valve (MV) regurgitation due to degenerative MV disease is the leading cause of cardiac death in dogs. We carried out preliminary experiments to determine the feasibility and short-term effects of beating-heart MV repair using an expanded polytetrafluorethylene (ePTFE) chordal implantation device (Harpoon TSD-5) in dogs. This study involved six healthy purpose-bred Beagles (weight range 8.9-11.4 kg). Following a mini-thoracotomy performed under general anesthesia, the TSD-5 was used to place 1 or 2 artificial ePTFE cords on the anterior MV leaflet or the posterior MV leaflet via a left-ventricular transapical approach. The procedure was guided and monitored by transesophageal echocardiography. Postoperative antithrombotic treatment consisted of clopidogrel or a combination of clopidogrel and apixaban. Dogs were serially evaluated by transthoracic echocardiography at day 1, 7, 14, 21, and 30. The hearts were then examined for evaluation of tissues reactions and to detect signs of endothelialization. One or two chords were successfully implanted in five dogs. Four dogs completed the 30 days follow-up. One dog died intra-operatively because of aortic perforation. One dog died early post-operatively from a hemorrhagic pleural effusion attributed to overly aggressive antithrombotic treatment. One dog developed a thrombus surrounding both the knot and the synthetic cord. Postmortem exam confirmed secure placement of ePTFE knots in the mitral leaflets in all dogs and the presence of endothelialization of the knots and chords. These preliminary results demonstrate the feasibility of artificial chordal placement using an ePTFE cordal implantation device in dogs. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. White Paper: Curriculum in Interventional Radiology.

    PubMed

    Mahnken, Andreas H; Bücker, Arno; Hohl, Christian; Berlis, Ansgar

    2017-04-01

    Purpose  Scope and clinical importance of interventional radiology markedly evolved over the last decades. Consequently it was acknowledged as independent subspecialty by the "European Union of Medical Specialists" (UEMS). Based on radiological imaging techniques Interventional Radiology is an integral part of Radiology. Materials und Methods  In 2009 the German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a structured training in Interventional Radiology. In cooperation with the German Society of Neuroradiology (DGNR) this training was extended to also cover Interventional Neuroradiology in 2012. Tailored for this training in Interventional Radiology a structured curriculum was developed, covering the scope of this modular training. Results  The curriculum is based on the DeGIR/DGNR modular training concept in Interventional Radiology. There is also an European Curriculum and Syllabus for Interventional Radiology developed by the "Cardiovascular and Interventional Radiological Society of Europe" (CIRSE). The presented curriculum in Interventional Radiology is designed to provide a uniform base for the training in Interventional Radiology in Germany, based on the competencies obtained during residency. Conclusion  This curriculum can be used as a basis for training in Interventional Radiology by all training sites. Key Points: · Interventional Radiology is an integral part of clinical radiology. · The German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a curriculum in Interventional Radiology. · This curriculum is an integrative basis for the training in interventional. Citation Format · Mahnken AH, Bücker A, Hohl C et al. White Paper: Curriculum in Interventional Radiology. Fortschr Röntgenstr 2017; 189: 309 - 311. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Primary prevention of peri-implantitis: managing peri-implant mucositis.

    PubMed

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; Lambert, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni E; Schwarz, Frank; Serino, Giovanni; Tomasi, Cristiano; Zitzmann, Nicola U

    2015-04-01

    Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considered as a preventive measure for the onset of peri-implantitis. Therefore, the remit of this working group was to assess the prevalence of peri-implant diseases, as well as risks for peri-implant mucositis and to evaluate measures for the management of peri-implant mucositis. Discussions were informed by four systematic reviews on the current epidemiology of peri-implant diseases, on potential risks contributing to the development of peri-implant mucositis, and on the effect of patient and of professionally administered measures to manage peri-implant mucositis. This consensus report is based on the outcomes of these systematic reviews and on the expert opinion of the participants. Key findings included: (i) meta-analysis estimated a weighted mean prevalence for peri-implant mucositis of 43% (CI: 32-54%) and for peri-implantitis of 22% (CI: 14-30%); (ii) bleeding on probing is considered as key clinical measure to distinguish between peri-implant health and disease; (iii) lack of regular supportive therapy in patients with peri-implant mucositis was associated with increased risk for onset of peri-implantitis; (iv) whereas plaque accumulation has been established as aetiological factor, smoking was identified as modifiable patient-related and excess cement as local risk indicator for the development of peri-implant mucositis; (v) patient-administered mechanical plaque control (with manual or powered toothbrushes) has been shown to be an effective preventive measure; (vi) professional intervention

  2. Vacuum die attach for integrated circuits

    DOEpatents

    Schmitt, Edward H.; Tuckerman, David B.

    1991-01-01

    A thin film eutectic bond for attaching an integrated circuit die to a circuit substrate is formed by coating at least one bonding surface on the die and substrate with an alloying metal, assembling the die and substrate under compression loading, and heating the assembly to an alloying temperature in a vacuum. A very thin bond, 10 microns or less, which is substantially void free, is produced. These bonds have high reliability, good heat and electrical conduction, and high temperature tolerance. The bonds are formed in a vacuum chamber, using a positioning and loading fixture to compression load the die, and an IR lamp or other heat source. For bonding a silicon die to a silicon substrate, a gold silicon alloy bond is used. Multiple dies can be bonded simultaneously. No scrubbing is required.

  3. Activity-based costing in radiology. Application in a pediatric radiological unit.

    PubMed

    Laurila, J; Suramo, I; Brommels, M; Tolppanen, E M; Koivukangas, P; Lanning, P; Standertskjöld-Nordenstam, G

    2000-03-01

    To get an informative and detailed picture of the resource utilization in a radiology department in order to support its pricing and management. A system based mainly on the theoretical foundations of activity-based costing (ABC) was designed, tested and compared with conventional costing. The study was performed at the Pediatric Unit of the Department of Radiology, Oulu University Hospital. The material consisted of all the 7,452 radiological procedures done in the unit during the first half of 1994, when both methods of costing where in use. Detailed cost data were obtained from the hospital financial and personnel systems and then related to activity data captured in the radiology information system. The allocation of overhead costs was greatly reduced by the introduction of ABC compared to conventional costing. The overhead cost as a percentage of total costs dropped to one-fourth of total costs, from 57% to 16%. The change of unit costs of radiological procedures varied from -42% to +82%. Costing is much more detailed and precise, and the percentage of unspecified allocated overhead costs diminishes drastically when ABC is used. The new information enhances effective departmental management, as the whole process of radiological procedures is identifiable by single activities, amenable to corrective actions and process improvement.

  4. Assessment of radiological protection systems among diagnostic radiology facilities in North East India.

    PubMed

    Singh, Thokchom Dewan; Jayaraman, T; Arunkumar Sharma, B

    2017-03-01

    This study aims to assess the adequacy level of radiological protection systems available in the diagnostic radiology facilities located in three capital cities of North East (NE) India. It further attempts to understand, using a multi-disciplinary approach, how the safety codes/standards in diagnostic radiology framed by the Atomic Energy Regulatory Board (AERB) and the International Atomic Energy Agency (IAEA) to achieve adequate radiological protection in facilities, have been perceived, conceptualized, and applied accordingly in these facilities. About 30 diagnostic radiology facilities were randomly selected from three capitals of states in NE India; namely Imphal (Manipur), Shillong (Meghalaya) and Guwahati (Assam). A semi-structured questionnaire developed based on a multi-disciplinary approach was used for this study. It was observed that radiological practices undertaken in these facilities were not exactly in line with safety codes/standards in diagnostic radiology of the AERB and the IAEA. About 50% of the facilities had registered/licensed x-ray equipment with the AERB. More than 80% of the workers did not use radiation protective devices, although these devices were available in the facilities. About 85% of facilities had no institutional risk management system. About 70% of the facilities did not carry out periodic quality assurance testing of their x-ray equipment or surveys of radiation leakage around the x-ray room, and did not display radiation safety indicators in the x-ray rooms. Workers in these facilities exhibited low risk perception about the risks associated with these practices. The majority of diagnostic radiology facilities in NE India did not comply with the radiological safety codes/standards framed by the AERB and IAEA. The study found inadequate levels of radiological protection systems in the majority of facilities. This study suggests a need to establish firm measures that comply with the radiological safety codes/standards of the

  5. [Dying and death in societal transformation].

    PubMed

    Heller, Andreas; Wegleitner, Klaus

    2017-01-01

    Dying and death in modern societies are subject to profound social, professional and cultural-religious changes. Secularization and a stronger differentiation of societies have led to a change in the way humans handle the dying process. Normatively ritualized collective behaviour has been replaced by an individual, subjectivized approach. In late modern societies there are many different views of what "successful" or "good" dying means.In the article this change is described by the following seven theses: 1. We live longer and we die longer. 2. We no longer die suddenly and unexpectedly but slowly and foreseeably. 3. Even though our biological life on earth has become longer, our life has been shortened by the loss of eternity. 4. We no longer die on the stage of ritualized relationships with our family and neighbours but behind the curtains of organizations. 5. We live and die in a society of organizations and have to get organized for the final phase of our life. 6. Living and dying are no large, state-owned enterprises but small, private enterprises. 7. The hospice movement as well as palliative medicine have created public awareness, made dying a matter of discussion and offered a new set of options.In late modernism end-of-life care requires new approaches based on individual and shared responsibility as well as cooperation between professional institutions and community-based voluntary care.A change towards community care is visible. Thus "dying" is a topic in the discussion about the future of public health and societal solidarity.

  6. Apparatus for restraining and transporting dies

    DOEpatents

    Allison, James W.; LaBarre, Timothy L.

    1994-01-01

    Apparatus for restraining and transporting dies in punch press operations is provided. A floatation platen for supporting a die on the platen's upper surface has a plurality of recessed gas exhaust ports on the platen's lower surface. A source of pressurized gas delivers gas to a platen manifold, for delivery to orifices located in the gas exhaust ports. The flow of gas is controlled by a first valve adjacent the gas source and a second valve adjacent the manifold, with the second valve being used to control the gas flow during movement of the die. In this fashion, a die may be moved on a cushion of air from one workstation to a selected second workstation. A moveable hydraulically operated restraining fixture is also provided, for clamping the die in position during the compacting phase, and for releasing the die after completion of the compacting phase by releasing the hydraulic pressure on the restraining fixture. When pressure in the hydraulic cylinders on the restraining fixture is reversed, the restraining fixture will retract so that there is no contact between the die and the restraining fixture, thereby allowing the die to be removed from a first workstation and moved to a second selected workstation.

  7. Vacuum die attach for integrated circuits

    DOEpatents

    Schmitt, E.H.; Tuckerman, D.B.

    1991-09-10

    A thin film eutectic bond for attaching an integrated circuit die to a circuit substrate is formed by coating at least one bonding surface on the die and substrate with an alloying metal, assembling the die and substrate under compression loading, and heating the assembly to an alloying temperature in a vacuum. A very thin bond, 10 microns or less, which is substantially void free, is produced. These bonds have high reliability, good heat and electrical conduction, and high temperature tolerance. The bonds are formed in a vacuum chamber, using a positioning and loading fixture to compression load the die, and an IR lamp or other heat source. For bonding a silicon die to a silicon substrate, a gold silicon alloy bond is used. Multiple dies can be bonded simultaneously. No scrubbing is required. 1 figure.

  8. Reinraumtechnik für die Medizintechnik

    NASA Astrophysics Data System (ADS)

    Petek, Max; Jungbluth, Martin; Krampe, Erhard

    Die Reinraumtechnik ist heute ein unverzichtbarer Bestandteil bei der Fertigung von Produkten der Life Sciences, den Bereichen Pharma, Lebensmittel, Kosmetik und Medizintechnik. In Anbetracht der langen Historie der Medizintechnik ist sie jedoch eine sehr junge Disziplin. Die Bedeutung von Keimen und die richtige Einschätzung ihrer Größe wurden zwar sehr früh bereits durch Paracelsus erkannt, jedoch wurden daraus noch keine speziellen oder kontinuierlich umgesetzten Hygienevorschriften abgeleitet. Die erste bekannte technische Umsetzung von Hygieneempfehlungen geht auf den Franzosen François Nicolas Appert zurück, der eine aseptische Abfüllmethode für Lebensmittel entwickelte und diese 1810 veröffentlichte [1]. Die erste dokumentierte medizinische Umsetzung stellten Hygienevorschriften für Ärzte dar, die Ignaz Philipp Semmelweis nach 1847 in der Wiener Klinik für Geburtshilfe einführte [2].

  9. Short Implants Versus Standard Implants: Midterm Outcomes of a Clinical Study.

    PubMed

    Benlidayi, M Emre; Ucar, Yurdanur; Tatli, Ufuk; Ekren, Orhun; Evlice, Burcu; Kisa, Halil Ibrahim; Baksi, Uygar

    2018-02-01

    The aim of this study was to evaluate the midterm survival rate, marginal bone resorption (MBR), and stability of short implants and to compare the results with standard length implants. A total of 38 patients were included. In total, 147 implants (Nucleoss Implants, Izmir, Turkey) were placed (86 short implants and 61 standard implants). Cement-retained metal-ceramic prostheses were fabricated. MBR was evaluated on periapical radiographs taken at implant placement, at the time of crown insertion and annually thereafter. The stability of the implants was evaluated by resonance frequency analysis. The 3- and 5-year cumulative survival rates for standard implants was 98.4% and for short implants was 96.5% (P = 0.644). The MBR of the short implants was significantly lower than that of the standard implants after 1, 2, and 3 years of loading (P < 0.05). No significant differences were found between 2 groups after 6 and 12 months of loading in terms of implant stability (implant stability quotient values) (P > 0.05). Within the limits of this study, it is concluded that short implants achieved similar results as standard implants after 3 to 5 years of loading.

  10. Asian Radiology Forum 2016 for Promoting Radiology Together in the Asian-Oceanian Region: Roles of the Asian-Oceanian Society of Radiology and Its Member Societies

    PubMed Central

    Kim, Ho Sung; Choi, Jung-Ah

    2018-01-01

    According to the reports presented at the second Asian Radiology Forum (ARF) 2016, organized by the Korean Society of Radiology (KSR) during the Korean Congress of Radiology (KCR) in September 2016 in Seoul, there is an increasing need for the Asian-Oceanian Society of Radiology (AOSR) and its member societies to promote radiology together in the Asian-Oceanian region. In ARF 2016, the national delegates of the Asian-Oceanian radiological partner societies primarily discussed their societies' activities and contributions in international and regional societies including AOSR, expectations for AOSR, recommendations and suggestions for AOSR, and their societies' support of AOSR. PMID:29520175

  11. Effect of abutment height on interproximal implant bone level in the early healing: A randomized clinical trial.

    PubMed

    Blanco, Juan; Pico, Alexandre; Caneiro, Leticia; Nóvoa, Lourdes; Batalla, Pilar; Martín-Lancharro, Pablo

    2018-01-01

    The aim of this randomized clinical trial was to compare the effect on the interproximal implant bone loss (IBL) of two different heights (1 and 3 mm) of definitive abutments placed at bone level implants with a platform switched design. Twenty-two patients received forty-four implants (6.5-10 mm length and 3.5-4 mm diameter) to replace at least two adjacent missing teeth, one bridge set to each patient-two implants per bridge. Patients were randomly allocated, and two different abutment heights, 1 and 3 mm using only one abutment height per bridge, were used. Clinical and radiological measurements were performed at 3 and 6 months after surgery. Interproximal bone level changes were compared between treatment groups. The association between IBL and categorical variables (history of periodontitis, smoking, implant location, implant diameter, implant length, insertion torque, width of keratinized mucosa, bone density, gingival biotype and antagonist) was also performed. At 3 months, implants with a 1-mm abutment had significantly greater IBL (0.83 ± 0.19 mm) compared to implants with a 3-mm abutment (0.14 ± 0.08 mm). At 6 months, a greater IBL was observed at implants with 1-mm abutments compared to implants with 3-mm abutments (0.91 ± 0.19 vs. 0.11 ± 0.09 mm). The analysis of the relation between patient characteristics and clinical variables with IBL revealed no significant differences at any moment except for smoking. Abutment height is an important factor to maintain interproximal implant bone level in early healing. Short abutments led to a greater interproximal bone loss in comparison with long abutments after 6 months. Other variables except smoking showed no relation with interproximal bone loss in early healing. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Strategies to improve electrode positioning and safety in cochlear implants.

    PubMed

    Rebscher, S J; Heilmann, M; Bruszewski, W; Talbot, N H; Snyder, R L; Merzenich, M M

    1999-03-01

    An injection-molded internal supporting rib has been produced to control the flexibility of silicone rubber encapsulated electrodes designed to electrically stimulate the auditory nerve in human subjects with severe to profound hearing loss. The rib molding dies, and molds for silicone rubber encapsulation of the electrode, were designed and machined using AutoCad and MasterCam software packages in a PC environment. After molding, the prototype plastic ribs were iteratively modified based on observations of the performance of the rib/silicone composite insert in a clear plastic model of the human scala tympani cavity. The rib-based electrodes were reliably inserted farther into these models, required less insertion force and were positioned closer to the target auditory neural elements than currently available cochlear implant electrodes. With further design improvements the injection-molded rib may also function to accurately support metal stimulating contacts and wire leads during assembly to significantly increase the manufacturing efficiency of these devices. This method to reliably control the mechanical properties of miniature implantable devices with multiple electrical leads may be valuable in other areas of biomedical device design.

  13. Long-Term Survival of Dental Implants with Different Prosthetic Loading Times in Healthy Patients: A 5-Year Retrospective Clinical Study.

    PubMed

    Muelas-Jiménez, M Isabel; Olmedo-Gaya, Maria Victoria; Manzano-Moreno, Francisco J; Reyes-Botella, Candela; Vallecillo-Capilla, Manuel

    2017-02-01

    To compare survival rates among dental implants restored with immediate, early, and conventional loading protocols, also comparing between maxillary and mandibular implants, and to evaluate the influence of implant length and diameter and the type of prosthesis on treatment outcomes. This retrospective cohort study initially included all 52 patients receiving dental implants between July 2006 and February 2008 at a private oral surgery clinic in Granada (Southern Spain). Clinical and radiographic examinations were performed, including periapical or panoramic radiographs, and incidences during completion of the restoration were recorded at 1 week, 3 months, 6 months, and at 1, 2, 3, 4, and 5 years. After a 5-year follow-up, 1 patient had died, 3 were lost to follow-up, and 6 required grafting before implant placement; therefore, the final study sample comprised 42 patients with 164 implants. Variables associated with the survival/failure of the restoration were: number of implants (higher failure rate with fewer implants), bone type (higher failure rate in type III or IV bone), and type of prosthesis (higher failure rate with single crowns). No significant association was found in univariate or multivariate analyses between survival rate and the loading protocol, implant length or diameter, or maxillary/mandibular location. Immediate occlusal loading, immediate provisionalization without occlusal loading, and early loading are viable treatment options with similar survival rates to those obtained with conventional loading. Bone quality and number of implants per patient were the most influential factors. © 2015 by the American College of Prosthodontists.

  14. Analysis of migration of the Nanos® short-stem hip implant within two years after surgery.

    PubMed

    Budde, Stefan; Seehaus, Frank; Schwarze, Michael; Hurschler, Christof; Floerkemeier, Thilo; Windhagen, Henning; Noll, Yvonne; Ettinger, Max; Thorey, Fritz

    2016-08-01

    Short-stem implants provide a bone-preserving alternative in total hip arthroplasty. However, some evidence exists that the smaller implant-bone contact surface may compromise primary stability and impair osseo-integration. The purpose of this study was to analyse the migration characteristics of the Nanos® short stem over two years by means of model-based roentgen stereophotogrammetric analysis (MBRSA). Eighteen patients aged 53.6 ± 7.2 years were included. After being treated with a Nanos implant, 14 patients were followed-up radiologically at three, six, 12 and 24 months by means of MBRSA. Early implant migration was calculated. Clinical data have been assessed in addition. Highest translational migration was observed with a mean value of -0.22 ± 0.39 mm along the proximo-distal axis after three months and highest rotational migration with 0.8 ± 3.2° also around the y-axis after two years. The resulting total migration was 0.46 ± 0.31 mm, with the largest proportion occurring within three months after surgery (0.40 ± 0.34 mm). The Nanos short-stem hip implant shows only a slight initial migration within three months after implantation, followed by secondary stabilisation. These results suggest both good primary stability and osseo-integration, suggesting a low risk of aseptic loosening.

  15. Contoured Orifice for Silicon-Ribbon Die

    NASA Technical Reports Server (NTRS)

    Mackintosh, B. H.

    1985-01-01

    Die configuration encourages purity and stable growth. Contour of die orifice changes near ribbon edges. As result, silicon ribbon has nearly constant width and little carbon contamination. Die part of furnace being developed to produce high-quality, low-cost material for solar cells.

  16. CAE Based Die Face Engineering Development to Contribute to the Revitalization of the Tool & Die Industry

    NASA Astrophysics Data System (ADS)

    Tang, Arthur; Lee, Wing C.; St. Pierre, Shawn; He, Jeanne; Liu, Kesu; Chen, Chin C.

    2005-08-01

    Over the past two decades, the Computer Aided Engineering (CAE) tools have emerged as one of the most important engineering tools in various industries, due to its flexibility and accuracy in prediction. Nowadays, CAE tools are widely used in the sheet metal forming industry to predict the forming feasibility of a wide variety of complex components, ranging from aerospace and automotive components to household products. As the demand of CAE based formability accelerates, the need for a robust and streamlined die face engineering tool becomes more crucial, especially in the early stage when the tooling layout is not available, but a product design decision must be made. Ability to generate blank, binder and addendum surfaces with an appropriate layout of Drawbead, Punch Opening Line, Trim Line are the primary features and functions of a CAE based die face engineering tool. Once the die face layout is ready, a formability study should be followed to verify the die face layout is adequate to produce a formable part. If successful, the established die face surface should be exported back to the CAD/CAM environment to speed up the tooling and manufacturing design process with confidence that this particular part is formable with this given die face. With a CAE tool as described above, the tool & die industry will be greatly impacted as the processes will enable the bypass of hardware try-out and shorten the overall vehicle production timing. The trend has shown that OEMs and first tiers will source to low cost producers in the world which will have a negative impact to the traditional tool & die makers in the developed countries. CAE based tool as described should be adopted, along with many other solutions, in order to maintain efficiency of producing high quality product and meeting time-to-market requirements. This paper will describe how a CAE based die face engineering (DFE) tool could be further developed to enable the traditional tool & die makers to meet the

  17. A 5-year clinical and computerized tomographic implant follow-up in sinus-lifted maxillae and native bone.

    PubMed

    Sbordone, Carolina; Toti, Paolo; Ramaglia, Luca; Guidetti, Franco; Sbordone, Ludovico; Martuscelli, Ranieri

    2014-09-01

    The present study analysed apical and marginal bone remodelling around dental implants placed in both maxillary (sinus elevated with particulated autogenous osseous graft) and corresponding native bone areas, with a follow-up of 5 years. The clinical survival of implants was also observed. In this retrospective chart review, 27 patients were enrolled, with 55 dental implants inserted from 2000 to 2006, 26 of which were followed (one implant per patient); if required, patients were treated via sinus lift with autogenous bone and particulate technique. The internal controls were implants positioned in native areas beneath the sinus. Radiologic survey was assessed via computerized tomographic analysis measuring apical bone level (ABL) and marginal bone level (MBL), at 1- (T1 ), 3- (T2 ) and 5 years (T3 ), around implants (buccal, b; palatal, p; mesial, m; and distal sides, d). Clinical probing depth (CPD) and clinical attachment level (CAL) for all the four peri-implant aspects were measured. Cumulative survival rate (CSR) and survival rate (SR) of implants were calculated. Significances for paired and unpaired comparisons were searched for. A significant degree of apical resorption was recorded between T1 and T3 for the mesial particulate group; again, a significant difference was discovered between the native and particulate procedures for mABL. A further feature was discovered for the particulate procedure, for which ABLs resulted negative at least for three of the aspects. Regarding MBL measurements, similar behaviours were revealed using time-comparison analysis for the two procedures at the buccal aspect. Comparisons among diameters, irrespective of the procedure, showed that resorption times for the bMBL were shorter as the diameter of the implant became wider. The implant CSR was 92% in native areas (two failures/25 implants) and 93.3% in sinuses lifted with particulate bone (two failures/30 implants). The results suggest that a protrusion of the implant

  18. Three-Dimensional Nonlinear Finite Element Analysis and Microcomputed Tomography Evaluation of Microgap Formation in a Dental Implant Under Oblique Loading.

    PubMed

    Jörn, Daniela; Kohorst, Philipp; Besdo, Silke; Borchers, Lothar; Stiesch, Meike

    2016-01-01

    Since bacterial leakage along the implant-abutment interface may be responsible for peri-implant infections, a realistic estimation of the interface gap width during function is important for risk assessment. The purpose of this study was to compare two methods for investigating microgap formation in a loaded dental implant, namely, microcomputed tomography (micro-CT) and three-dimensional (3D) nonlinear finite element analysis (FEA); additionally, stresses to be expected during loading were also evaluated by FEA. An implant-abutment complex was inspected for microgaps between the abutment and implant in a micro-CT scanner under an oblique load of 200 N. A numerical model of the situation was constructed; boundary conditions and external load were defined according to the experiment. The model was refined stepwise until its load-displacement behavior corresponded sufficiently to data from previous load experiments. FEA of the final, validated model was used to determine microgap widths. These were compared with the widths as measured in micro-CT inspection. Finally, stress distributions were evaluated in selected regions. No microgaps wider than 13 μm could be detected by micro-CT for the loaded implant. FEA revealed gap widths up to 10 μm between the implant and abutment at the side of load application. Furthermore, FEA predicted plastic deformation in a limited area at the implant collar. FEA proved to be an adequate method for studying microgap formation in dental implant-abutment complexes. FEA is not limited in gap width resolution as are radiologic techniques and can also provide insight into stress distributions within the loaded complex.

  19. Overdentures in the edentulous mandible supported by implants and retained by a Dolder bar: a 5-year prospective study.

    PubMed

    Heschl, Alexander; Payer, Michael; Clar, Volker; Stopper, Marlene; Wegscheider, Walther; Lorenzoni, Martin

    2013-08-01

    This prospective study was performed to evaluate the outcomes of XiVE® S plus implants (Dentsply Friadent, Mannheim, Germany) following conventional restoration with bar structures and overdentures in the edentulous mandible. A total of 39 patients were treated with four interforaminal implants (n = 156) splinted by a Dolder bar. Overdentures were attached to the bars after 3 months of healing. As primary outcome measures, clinical and radiological parameters were evaluated at the time of implant placement (baseline) and once a year (1, 2, 3, 4, 5 years) after functional loading. Secondary outcome measures included (i) primary stability and surgical complications, as well as (ii) Periotest® (Medizintechnik Gulden, Modautal, Germany) values, implant survival, and prosthetic complications at baseline and follow-up. A total of 156 implants were placed. The vast majority (n = 149) were tightened to >30 Ncm, while torques in the range of 20-30 Ncm were obtained in the remaining cases (n = 7). Mean crestal bone levels around the implants were 0.41 mm at baseline and 1.04/1.20/1.34/1.45/1.44 mm after 1/2/3/4/5 years respectively. The mean values of the plaque, calculus, bleeding, and mucosal indices remained low throughout this period. The reported follow-up periods involved one implant loss after 3 months (survival rate: 99.4%) and one implant failure after 4 years (success rate: 98.4%). Prosthetic complications included factures of bars (n = 3) and denture teeth (n = 7). Prosthetic survival was 100%. Dolder bars to restore oral implants in the edentulous mandible appear to offer a high rate of implant survival, good stability of the peri-implant tissue, and a low rate of prosthetic complications. © 2011 Wiley Periodicals, Inc.

  20. Lateral approach for maxillary sinus membrane elevation without bone materials in maxillary mucous retention cyst with immediate or delayed implant rehabilitation: case reports.

    PubMed

    Han, Ji-Deuk; Cho, Seong-Ho; Jang, Kuk-Won; Kim, Seong-Gwang; Kim, Jung-Han; Kim, Bok-Joo; Kim, Chul-Hun

    2017-08-01

    This case series study demonstrates the possibility of successful implant rehabilitation without bone augmentation in the atrophic posterior maxilla with cystic lesion in the sinus. Sinus lift without bone graft using the lateral approach was performed. In one patient, the cyst was aspirated and simultaneous implantation under local anesthesia was performed, whereas the other cyst was removed under general anesthesia, and the sinus membrane was elevated in a second process, followed by implantation. In both cases, tapered 11.5-mm-long implants were utilized. With all of the implants, good stability and appropriate bone height were achieved. The mean bone level gain was 5.73 mm; adequate bone augmentation around the implants was shown, the sinus floor was moved apically, and the cyst was no longer radiologically detected. Completion of all of the treatments required an average of 12.5 months. The present study showed that sufficient bone formation and stable implantation in a maxilla of insufficient bone volume are possible through sinus lift without bone materials. The results serve to demonstrate, moreover, that surgical treatment of mucous retention cyst can facilitate rehabilitation. These techniques can reduce the risk of complications related to bone grafts, save money, and successfully treat antral cyst.

  1. Lateral approach for maxillary sinus membrane elevation without bone materials in maxillary mucous retention cyst with immediate or delayed implant rehabilitation: case reports

    PubMed Central

    2017-01-01

    This case series study demonstrates the possibility of successful implant rehabilitation without bone augmentation in the atrophic posterior maxilla with cystic lesion in the sinus. Sinus lift without bone graft using the lateral approach was performed. In one patient, the cyst was aspirated and simultaneous implantation under local anesthesia was performed, whereas the other cyst was removed under general anesthesia, and the sinus membrane was elevated in a second process, followed by implantation. In both cases, tapered 11.5-mm-long implants were utilized. With all of the implants, good stability and appropriate bone height were achieved. The mean bone level gain was 5.73 mm; adequate bone augmentation around the implants was shown, the sinus floor was moved apically, and the cyst was no longer radiologically detected. Completion of all of the treatments required an average of 12.5 months. The present study showed that sufficient bone formation and stable implantation in a maxilla of insufficient bone volume are possible through sinus lift without bone materials. The results serve to demonstrate, moreover, that surgical treatment of mucous retention cyst can facilitate rehabilitation. These techniques can reduce the risk of complications related to bone grafts, save money, and successfully treat antral cyst. PMID:28875144

  2. An implantable integrated low-power amplifier-microelectrode array for Brain-Machine Interfaces.

    PubMed

    Patrick, Erin; Sankar, Viswanath; Rowe, William; Sanchez, Justin C; Nishida, Toshikazu

    2010-01-01

    One of the important challenges in designing Brain-Machine Interfaces (BMI) is to build implantable systems that have the ability to reliably process the activity of large ensembles of cortical neurons. In this paper, we report the design, fabrication, and testing of a polyimide-based microelectrode array integrated with a low-power amplifier as part of the Florida Wireless Integrated Recording Electrode (FWIRE) project at the University of Florida developing a fully implantable neural recording system for BMI applications. The electrode array was fabricated using planar micromachining MEMS processes and hybrid packaged with the amplifier die using a flip-chip bonding technique. The system was tested both on bench and in-vivo. Acute and chronic neural recordings were obtained from a rodent for a period of 42 days. The electrode-amplifier performance was analyzed over the chronic recording period with the observation of a noise floor of 4.5 microVrms, and an average signal-to-noise ratio of 3.8.

  3. Radiological evaluation of dysphagia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ott, D.J.; Gelfand, D.W.; Wu, W.C.

    1986-11-21

    Dysphagia is a common complaint in patients presenting for radiological or endoscopic examination of the esophagus and is usually due to functional or structural abnormalities of the esophageal body or esophagogastric region. The authors review the radiological evaluation of the esophagus and esophagogastric region in patients with esophageal dysphagia and discuss the roentgenographic techniques used, radiological efficacy for common structural disorders, and evaluation of esophageal motor function. Comparison is made with endoscopy in assessing dysphagia, with the conclusion that the radiological examination be used initially in patients with this complaint.

  4. Navigating "Assisted Dying".

    PubMed

    Schipper, Harvey

    2016-02-01

    Carter is a bellwether decision, an adjudication on a narrow point of law whose implications are vast across society, and whose impact may not be realized for years. Coupled with Quebec's Act Respecting End-of-life Care it has sharply changed the legal landscape with respect to actively ending a person's life. "Medically assisted dying" will be permitted under circumstances, and through processes, which have yet to be operationally defined. This decision carries with it moral assumptions, which mean that it will be difficult to reach a unifying consensus. For some, the decision and Act reflect a modern acknowledgement of individual autonomy. For others, allowing such acts is morally unspeakable. Having opened the Pandora's Box, the question becomes one of navigating a tolerable societal path. I believe it is possible to achieve a workable solution based on the core principle that "medically assisted dying" should be a very rarely employed last option, subject to transparent ongoing review, specifically as to why it was deemed necessary. My analysis is based on 1. The societal conditions in which have fostered demand for "assisted dying", 2. Actions in other jurisdictions, 3. Carter and Quebec Bill 52, 4. Political considerations, 5. Current medical practice. Leading to a series of recommendations regarding. 1. Legislation and regulation, 2. The role of professional regulatory agencies, 3. Medical professions education and practice, 4. Public education, 5. Health care delivery and palliative care. Given the burden of public opinion, and the legal steps already taken, a process for assisted-dying is required. However, those legal and regulatory steps should only be considered a necessary and defensive first step in a two stage process. The larger goal, the second step, is to drive the improvement of care, and thus minimize assisted-dying.

  5. Educational treasures in radiology: a free online program for Radiology Boards preparation.

    PubMed

    Talanow, Roland

    2011-01-01

    An objective tool is desired, which optimally prepares for Radiology boards examination. Such program should prepare examinees with pertinent radiological contents and simulations as expected in the real examination. Many countries require written boards examinations for Radiology certification eligibility. No objective measure exists to tell if the examinee is ready to pass the exam or not. Time pressure and computer environment might be unfamiliar to examinees. Traditional preparation lectures don't simulate the "real" Radiology exam because they don't provide the special environment with multiple choice questions and timing. This online program consists of 4 parts. The entry section allows to create questions with additional fields for comprehensive information. Sections include Pediatrics/Mammography/GI/IR/Nucs/Thoracic/Musculoskeletal/GU/Neuro/Ultrasound/Cardiac/OB/GYN and Miscellaneous. Experienced radiologists and educators evaluate and release/delete these entries in the administrator section. In the exam section users can create (un)timed customized exams for individual needs and learning pace. Exams can either include all sections or only specific sections to gear learning towards areas with weaker performance. Comprehensive statistics unveil the user's strengths and weaknesses to help focussing on "weak" areas. In the search section a comprehensive search and review can be performed by searching the entire database for keywords/topics or only searching within specific sections. www.RadiologyBoards.org is a new working concept of Radiology boards preparation to detect and improve the examinee's weaknesses and finally to increase the examinee's confidence level for the final exam. It is beneficial for Radiology residents and also board certified radiologists to refresh/maintain radiological knowledge.

  6. Why are mini-implants lost: the value of the implantation technique!

    PubMed

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  7. Totally implanted ports: the trapezius approach in practice.

    PubMed

    Hill, Steve

    Implanted ports (IPs) are an essential device for many patients who require long-term vascular access. IPs offer some advantages over other central venous access devices, such as lifestyle, body image benefits and lower infection rates. A typical implantation site for a port is the anterior chest wall. For some patients with breast cancer who have metastatic chest wall disease this site may lead to problems with the function of the device if disease spreads to the port site. One option for this patient group is to place the implanted port over the trapezius muscle. This article discusses six patients, all of whom had metastatic breast cancer with some degree of subcutaneous disease on the anterior chest wall. Three patients had received trapezius port placements and three had anterior chest wall placements. A retrospective review of the patients' medical records was undertaken from the time of insertion until removal or until the patient died. The anterior chest wall group of patients had their devices in for an average of 368 days vs 214 in the trapezius group. The total complications were higher in the anterior chest wall group (7 vs 2 in the trapezius group). Disease spread to two of the devices in the anterior chest wall group meaning the devices could no longer be used. The trapezius approach appears to be a safe and a reliable form of vascular access and may offer fewer complications than the traditional method of anterior chest wall placement when standard anterior chest wall approach is not suitable.

  8. L-connect routing of die surface pads to the die edge for stacking in a 3D array

    DOEpatents

    Petersen, Robert W.

    2000-01-01

    Integrated circuit chips and method of routing the interface pads from the face of the chip or die to one or more sidewall surfaces of the die. The interconnection is routed from the face of the die to one or more edges of the die, then routed over the edge of the die and onto the side surface. A new pad is then formed on the sidewall surface, which allows multiple die or chips to be stacked in a three-dimensional array, while enabling follow-on signal routing from the sidewall pads. The routing of the interconnects and formation of the sidewall pads can be carried out in an L-connect or L-shaped routing configuration, using a metalization process such as laser pantography.

  9. Hydroxyapatite ocular implant and non-integrated implants in eviscerated patients

    PubMed Central

    Gradinaru, S; Popescu, V; Leasu, C; Pricopie, S; Yasin, S; Ciuluvica, R; Ungureanu, E

    2015-01-01

    Introduction: This study compares the outcomes and complications of hydroxyapatite ocular implant and non-integrated ocular implants following evisceration. Materials and Methods: This is a retrospective study of 90 patients who underwent evisceration for different ocular affections, in the Ophthalmology Department of the University Emergency Hospital Bucharest, between January 2009 and December 2013. The outcomes measured were conjunctival dehiscence, socket infection, implant exposure and extrusion rate. Results: Forty-three patients had the hydroxyapatite implant (coralline–Integrated Ocular Implants, USA or synthetic–FCI, France) and forty-seven received non-integrated ocular implants (24 acrylic and 23 silicone). Five cases of socket infection, thirteen cases of extrusion and two cases of conjunctival dehiscence were encountered. Conclusions: There was a higher rate of conjunctival dehiscence with hydroxyapatite ocular implant, but implant extrusion and socket infection were found in non-integrated ocular implants. PMID:25914747

  10. Immediate direct-to-implant breast reconstruction using anatomical implants.

    PubMed

    Kim, Sung-Eun; Jung, Dong-Woo; Chung, Kyu-Jin; Lee, Jun Ho; Kim, Tae Gon; Kim, Yong-Ha; Lee, Soo Jung; Kang, Su Hwan; Choi, Jung Eun

    2014-09-01

    In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  11. Survival of dental implants placed in sites of previously failed implants.

    PubMed

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. The efficacy of two-stage titanium implants as orthodontic anchorage in the preprosthodontic correction of third molars in adults--a report of three cases.

    PubMed

    Haanaes, H R; Stenvik, A; Beyer-Olsen, E S; Tryti, T; Faehn, O

    1991-08-01

    Orthodontic movement of teeth is often required to satisfactorily treat a variety of oral rehabilitation problems. Considerable limitations in the clinical application of orthodontic treatment may result from the lack of teeth suitable for anchorage. Three patients with edentulous posterior segments are presented illustrating how implants can be utilized for preprosthodontic correction of impacted third molars rendering them suitable as bridge abutments. The patients have been followed for 8-10 years. Two-stage titanium implants were used as orthodontic anchorage as no dental anchorage was available. Edgewise orthodontic mechanics were used to move the third molars mesially with forces up to 2.5 N (about 250 g). No movement of the implants occurred and they were radiologically and clinically intact at the end of the orthodontic loading and were, therefore, subsequently used as bridge abutments.

  13. Sub-meninges implantation reduces immune response to neural implants.

    PubMed

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  14. Sub-meninges Implantation Reduces Immune Response to Neural Implants

    PubMed Central

    Markwardt, Neil T.; Stokol, Jodi; Rennaker, Robert L.

    2013-01-01

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. PMID:23370311

  15. Palliative Airway Stenting Performed Under Radiological Guidance and Local Anesthesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Profili, Stefano; Manca, Antonio; Feo, Claudio F.

    2007-02-15

    Purpose. To assess the effectiveness of airway stenting performed exclusively under radiological guidance for the palliation of malignant tracheobronchial strictures. Methods. We report our experience in 16 patients with malignant tracheobronchial stricture treated by insertion of 20 Ultraflex self-expandable metal stents performed under fluoroscopic guidance only. Three patients presented dysphagia grade IV due to esophageal malignant infiltration; they therefore underwent combined airway and esophageal stenting. All the procedures were performed under conscious sedation in the radiological room; average procedure time was around 10 min, but the airway impediment never lasted more than 40 sec. Results. We obtained an overall technicalmore » success in 16 cases (100%) and clinical success in 14 patients (88%). All prostheses were successfully placed without procedural complications. Rapid clinical improvement with symptom relief and normalization of respiratory function was obtained in 14 cases. Two patients died within 48 hr from causes unrelated to stent placement. Two cases (13%) of migration were observed; they were successfully treated with another stent. Tumor overgrowth developed in other 2 patients (13%); however, no further treatment was possible because of extensive laryngeal infiltration. Conclusions. Tracheobronchial recanalization with self-expandable metal stents is a safe and effective palliative treatment for malignant strictures. Airway stenting performed exclusively under fluoroscopic view was rapid and well tolerated.« less

  16. Ability of mini-implant-facilitated micro-osteoperforations to accelerate tooth movement in rats.

    PubMed

    Cheung, Tracy; Park, Juyoung; Lee, Deborah; Kim, Catherine; Olson, Jeffrey; Javadi, Shadi; Lawson, Gregory; McCabe, James; Moon, Won; Ting, Kang; Hong, Christine

    2016-12-01

    Although current techniques for accelerated tooth movement often involve invasive surgical procedures, micro-osteoperforations (MOPs) using mini-implants may facilitate orthodontic tooth movement without raising flaps, reduce surgical risks, and increase patient acceptance. In this study, we evaluated the effectiveness of mini-implant-facilitated MOPs in inducing accelerated tooth movement and investigated the potential risks for root resorption. Five MOPs were placed on the left side around the maxillary first molars in 6 rats using an automated mini-implant driver, whereas the right side received no MOPs as the control. Closed-coiled springs were secured from incisors to first molars for orthodontic tooth movement. Tooth movement was measured, and samples underwent radiologic and histologic analyses. The MOP side exhibited a 1.86-fold increase in the rate of tooth movement with decreased bone density and bone volume around the first molars compared with the control side. Hematoxylin and eosin and tartrate-resistant acid phosphatase analyses showed increased numbers of osteoclasts as well as new bone formation. Three-dimensional volumetric analysis of all 5 roots of the maxillary first molars demonstrated no statistically significant difference in root volumes. Mini-implant-facilitated MOPs accelerated tooth movement without increased risk for root resorption and therefore may become a readily available and efficient treatment option to shorten orthodontic treatment time with improved patient acceptance. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  17. Emergency management and infection control in a radiology department during an outbreak of severe acute respiratory syndrome.

    PubMed

    Lin, Y C; Dong, S L; Yeh, Y H; Wu, Y S; Lan, G Y; Liu, C M; Chu, T C

    2005-07-01

    The World Health Organization classified Taiwan as a serious epidemic-stricken area when the extent of severe acute respiratory syndrome (SARS) in Taiwan became clear. As of 11 July 2003, 671 probable SARS cases had been identified in Taiwan and 7 healthcare workers had died from the disease. Radiographers were easily infected by SARS because they had close contact with suspected or probable cases while conducting chest X-ray examinations. Three radiographers had been infected by the end of May 2003. Because of the impact of SARS on the Radiology Department, the department established a SARS emergency infection control team and re-designed the department's infection-control and emergency-management procedures based on the concept of risk-grade protection. This effort included installing a radiographic room at the fever-screening station, re-allocating human resources in the Radiology Department, training the department staff in infection control, and drafting new operational procedures for radiographers conducting X-ray examinations on SARS patients. The goal of this program was to reduce the infection rate and distribute materials efficiently in the department. This article introduces the emergency-management procedure of the Radiology Department during the SARS outbreak and the infection-protection experience of the department staff.

  18. Extrusion die and method

    DOEpatents

    Lipp, G. Daniel

    1994-05-03

    A method and die apparatus for manufacturing a honeycomb body of triangular cell cross-section and high cell density, the die having a combination of (i) feedholes feeding slot intersections and (ii) feedholes feeding slot segments not supplied from slot intersections, whereby a reduction in feedhole count is achieved while still retaining good extrusion efficiency and extrudate uniformity.

  19. Imaging of common breast implants and implant-related complications: A pictorial essay.

    PubMed

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  20. Effectiveness of enamel matrix derivative on the clinical and microbiological outcomes following surgical regenerative treatment of peri-implantitis. A randomized controlled trial.

    PubMed

    Isehed, Catrine; Holmlund, Anders; Renvert, Stefan; Svenson, Björn; Johansson, Ingegerd; Lundberg, Pernilla

    2016-10-01

    This randomized clinical trial aimed at comparing radiological, clinical and microbial effects of surgical treatment of peri-implantitis alone or in combination with enamel matrix derivative (EMD). Twenty-six subjects were treated with open flap debridement and decontamination of the implant surfaces with gauze and saline preceding adjunctive EMD or no EMD. Bone level (BL) change was primary outcome and secondary outcomes were changes in pocket depth (PD), plaque, pus, bleeding and the microbiota of the peri-implant biofilm analyzed by the Human Oral Microbe Identification Microarray over a time period of 12 months. In multivariate modelling, increased marginal BL at implant site was significantly associated with EMD, the number of osseous walls in the peri-implant bone defect and a Gram+/aerobic microbial flora, whereas reduced BL was associated with a Gram-/anaerobic microbial flora and presence of bleeding and pus, with a cross-validated predictive capacity (Q(2) ) of 36.4%. Similar, but statistically non-significant, trends were seen for BL, PD, plaque, pus and bleeding in univariate analysis. Adjunctive EMD to surgical treatment of peri-implantitis was associated with prevalence of Gram+/aerobic bacteria during the follow-up period and increased marginal BL 12 months after treatment. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Radiology and social media: are private practice radiology groups more social than academic radiology departments?

    PubMed

    Glover, McKinley; Choy, Garry; Boland, Giles W; Saini, Sanjay; Prabhakar, Anand M

    2015-05-01

    This study assesses the prevalence of use of the most commonly used social media sites among private radiology groups (PRGs) and academic radiology departments (ARDs). The 50 largest PRGs and the 50 ARDs with the highest level of funding from the National Institutes of Health were assessed for presence of a radiology-specific social media account on Facebook, Twitter, Instagram, Pinterest, YouTube, and LinkedIn. Measures of organizational activity and end-user activity were collected, including the number of posts and followers, as appropriate; between-group comparisons were performed. PRGs adopted Facebook 12 months earlier (P = .02) and Twitter 18 months earlier (P = .02) than did ARDs. A total of 76% of PRGs maintained ≥1 account on the social media sites included in the study, compared with 28% of ARDs (P < .0001). The prevalence of having an account on the social media sites for PRGs was: Facebook, 66%; LinkedIn, 56%; Twitter, 42%; YouTube, 20%; Pinterest, 4%; and Instagram, 2%. The prevalence of radiology-specific social media accounts for ARDs was: Facebook, 18%; LinkedIn, 0%; Twitter, 24%; YouTube, 6%; Pinterest, 0%; and Instagram, 0%. There was no significant difference between ARDs and PRGs in measures of end-user or organizational activity on Facebook or Twitter. Use of social media in health care is emerging as mainstream, with PRGs being early adopters of Facebook and Twitter in comparison with ARDs. Competitive environments and institutional policies may be strong factors that influence how social media is used by radiologists at the group and department levels. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Osseointegration and biocompatibility of different metal implants - a comparative experimental investigation in sheep

    PubMed Central

    2012-01-01

    Background In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep. Methods Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically. Results Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials. Conclusion This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior. PMID:22400715

  3. Imaging of common breast implants and implant-related complications: A pictorial essay

    PubMed Central

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer. PMID:27413269

  4. Ergonomics in radiology.

    PubMed

    Goyal, N; Jain, N; Rachapalli, V

    2009-02-01

    The use of computers is increasing in every field of medicine, especially radiology. Filmless radiology departments, speech recognition software, electronic request forms and teleradiology are some of the recent developments that have substantially increased the amount of time a radiologist spends in front of a computer monitor. Computers are also needed for searching literature on the internet, communicating via e-mails, and preparing for lectures and presentations. It is well known that regular computer users can suffer musculoskeletal injuries due to repetitive stress. The role of ergonomics in radiology is to ensure that working conditions are optimized in order to avoid injury and fatigue. Adequate workplace ergonomics can go a long way in increasing productivity, efficiency, and job satisfaction. We review the current literature pertaining to the role of ergonomics in modern-day radiology especially with the development of picture archiving and communication systems (PACS) workstations.

  5. How Secure Is Your Radiology Department? Mapping Digital Radiology Adoption and Security Worldwide.

    PubMed

    Stites, Mark; Pianykh, Oleg S

    2016-04-01

    Despite the long history of digital radiology, one of its most critical aspects--information security--still remains extremely underdeveloped and poorly standardized. To study the current state of radiology security, we explored the worldwide security of medical image archives. Using the DICOM data-transmitting standard, we implemented a highly parallel application to scan the entire World Wide Web of networked computers and devices, locating open and unprotected radiology servers. We used only legal and radiology-compliant tools. Our security-probing application initiated a standard DICOM handshake to remote computer or device addresses, and then assessed their security posture on the basis of handshake replies. The scan discovered a total of 2774 unprotected radiology or DICOM servers worldwide. Of those, 719 were fully open to patient data communications. Geolocation was used to analyze and rank our findings according to country utilization. As a result, we built maps and world ranking of clinical security, suggesting that even the most radiology-advanced countries have hospitals with serious security gaps. Despite more than two decades of active development and implementation, our radiology data still remains insecure. The results provided should be applied to raise awareness and begin an earnest dialogue toward elimination of the problem. The application we designed and the novel scanning approach we developed can be used to identify security breaches and to eliminate them before they are compromised.

  6. COMPARE/Radiology, an interactive Web-based radiology teaching program evaluation of user response.

    PubMed

    Wagner, Matthias; Heckemann, Rolf A; Nömayr, Anton; Greess, Holger; Bautz, Werner A; Grunewald, Markus

    2005-06-01

    The aim of this study is to assess user benefits of COMPARE/Radiology, a highly interactive World Wide Web-based training program for radiology, as perceived by its users. COMPARE/Radiology (http://www.idr.med.uni-erlangen.de/compare.htm), an interactive training program based on 244 teaching cases, was created by the authors and made publicly available on the Internet. An anonymous survey was conducted among users to investigate the composition of the program's user base and assess the acceptance of the training program. In parallel, Web access data were collected and analyzed using descriptive statistics. The group of responding users (n = 1370) consisted of 201 preclinical medical students (14.7%), 314 clinical medical students (22.9%), 359 residents in radiology (26.2%), and 205 users of other professions (14.9%). A majority of respondents (1230; 89%) rated the interactivity of COMPARE/Radiology as good or excellent. Many respondents use COMPARE/Radiology for self-study (971; 70%) and for teaching others (600; 43%). Web access statistics show an increase in number of site visits from 1248 in December 2002 to 4651 in April 2004. Users appreciate the benefits of COMPARE/Radiology. The interactive instructional design was rated positively by responding users. The popularity of the site is growing, evidenced by the number of network accesses during the observation period.

  7. Differentiating suicide decedents who died using firearms from those who died using other methods.

    PubMed

    Anestis, Michael D; Khazem, Lauren R; Anestis, Joye C

    2017-06-01

    Studies have documented a link between gun ownership and suicide, but little is known about characteristics of those most likely to use a gun in a suicide attempt rather than alternative methods. We examined which factors differentiate suicide decedents who died using a gun from those who died by other methods. We further examined whether such findings are consistent within the subcomponent of our larger sample comprised entirely of gun owning suicide decedents. Data reflect 267 suicide decedents, with data provided by individuals who identified as having lost someone to suicide (loss survivors). Within the full sample, a higher proportion of gun-owning and male suicide decedents died by firearm. Further, individuals who had previously discussed suicide or engaged in one or more non-lethal suicide attempts were less likely to die by suicide using a gun. Within the subsample of gun owning suicide decedents, a greater proportion of decedents who stored guns at home and in unsecure locations died from self-inflected gunshot wounds. These findings add clarity to the relationship between firearm ownership and death by suicide at the individual level. Furthermore, these findings are consistent with the notion that means safety implementation may represent a vital suicide prevention tool. Copyright © 2017. Published by Elsevier B.V.

  8. Energy Consumption of Die Casting Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jerald Brevick; clark Mount-Campbell; Carroll Mobley

    2004-03-15

    Molten metal processing is inherently energy intensive and roughly 25% of the cost of die-cast products can be traced to some form of energy consumption [1]. The obvious major energy requirements are for melting and holding molten alloy in preparation for casting. The proper selection and maintenance of melting and holding equipment are clearly important factors in minimizing energy consumption in die-casting operations [2]. In addition to energy consumption, furnace selection also influences metal loss due to oxidation, metal quality, and maintenance requirements. Other important factors influencing energy consumption in a die-casting facility include geographic location, alloy(s) cast, starting formmore » of alloy (solid or liquid), overall process flow, casting yield, scrap rate, cycle times, number of shifts per day, days of operation per month, type and size of die-casting form of alloy (solid or liquid), overall process flow, casting yield, scrap rate, cycle times, number of shifts per day, days of operation per month, type and size of die-casting machine, related equipment (robots, trim presses), and downstream processing (machining, plating, assembly, etc.). Each of these factors also may influence the casting quality and productivity of a die-casting enterprise. In a die-casting enterprise, decisions regarding these issues are made frequently and are based on a large number of factors. Therefore, it is not surprising that energy consumption can vary significantly from one die-casting enterprise to the next, and within a single enterprise as function of time.« less

  9. Cochlear implants in children implanted in Jordan: A parental overview.

    PubMed

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (p<0.05). Despite the general satisfaction from the information quantity and quality prior to cochlear implant, parents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  10. Transfemoral access when superior venous approach is not feasible equals overall success of permanent pacemaker implantation. Ten-year series.

    PubMed

    García Guerrero, Juan J; Fernández de la Concha Castañeda, Joaquín; Doblado Calatrava, Manuel; Redondo Méndez, Ángel; Lázaro Medrano, Manuel; Merchán Herrera, Antonio

    2017-06-01

    When permanent pacemaker implantation is not possible or advisable via superior venous access (i.e., axillary or subclavian veins), safe and feasible surgical alternatives are required. The femoral approach is relatively unknown and seldom studied. This single-center study analyzed 10-year outcomes of a femoral implantation approach. Data about the implantation procedure (indication, approach, lead and pacemaker models, complications), patient characteristics (age, sex, medications, comorbidities), and follow-up were analyzed for all permanent pacemaker implantations using the femoral approach between June 2001 and June 2011. A permanent pacemaker was implanted with the femoral approach in 50 patients (mean age, 76 years [range: 45-96], 31 [61%] men). The most frequent indication was atrioventricular block, associated with sinus rhythm in 30 patients and with atrial fibrillation in eight patients. Overall, 20 patients (40%) were treated with oral anticoagulants postimplantation. Mean implantation time was 64 minutes (range: 20-210) and mean fluoroscopy time was 6.7 minutes (range: 0.2-50). Minimum follow-up window was 1 year (June 2012), with a mean of 50 months [range: 1-113]). No deaths, septic episodes, or severe complications were associated with the procedure, acute or long-term. Follow-up data were available for 46 patients, of who 21 (46%) died during follow-up (mean age, 87 years [range: 73-101]). No cause of death was associated with the femoral technique. Permanent pacemaker implantation through femoral access is not difficult for an experienced implant surgeon. Outcomes were comparable to systems implanted by superior venous approach, and no severe complications were observed at 10-year follow-up. © 2017 Wiley Periodicals, Inc.

  11. Declarations on euthanasia and assisted dying.

    PubMed

    Inbadas, Hamilton; Zaman, Shahaduz; Whitelaw, Sandy; Clark, David

    2017-10-01

    Declarations on end-of-life issues are advocacy interventions that seek to influence policy, raise awareness and call others to action. Despite increasing prominence, they have attracted little attention from researchers. This study tracks the emergence, content, and purpose of declarations concerned with assisted dying and euthanasia, in the global context. The authors identified 62 assisted dying/euthanasia declarations covering 1974-2016 and analyzed them for originating organization, geographic scope, format, and stated viewpoint on assisted dying/euthanasia. The declarations emerged from diverse organizational settings and became more frequent over time. Most opposed assisted dying/euthanasia.

  12. Declarations on euthanasia and assisted dying

    PubMed Central

    Inbadas, Hamilton; Zaman, Shahaduz; Whitelaw, Sandy; Clark, David

    2017-01-01

    ABSTRACT Declarations on end-of-life issues are advocacy interventions that seek to influence policy, raise awareness and call others to action. Despite increasing prominence, they have attracted little attention from researchers. This study tracks the emergence, content, and purpose of declarations concerned with assisted dying and euthanasia, in the global context. The authors identified 62 assisted dying/euthanasia declarations covering 1974–2016 and analyzed them for originating organization, geographic scope, format, and stated viewpoint on assisted dying/euthanasia. The declarations emerged from diverse organizational settings and became more frequent over time. Most opposed assisted dying/euthanasia. PMID:28398131

  13. Informatics in radiology: radiology gamuts ontology: differential diagnosis for the Semantic Web.

    PubMed

    Budovec, Joseph J; Lam, Cesar A; Kahn, Charles E

    2014-01-01

    The Semantic Web is an effort to add semantics, or "meaning," to empower automated searching and processing of Web-based information. The overarching goal of the Semantic Web is to enable users to more easily find, share, and combine information. Critical to this vision are knowledge models called ontologies, which define a set of concepts and formalize the relations between them. Ontologies have been developed to manage and exploit the large and rapidly growing volume of information in biomedical domains. In diagnostic radiology, lists of differential diagnoses of imaging observations, called gamuts, provide an important source of knowledge. The Radiology Gamuts Ontology (RGO) is a formal knowledge model of differential diagnoses in radiology that includes 1674 differential diagnoses, 19,017 terms, and 52,976 links between terms. Its knowledge is used to provide an interactive, freely available online reference of radiology gamuts ( www.gamuts.net ). A Web service allows its content to be discovered and consumed by other information systems. The RGO integrates radiologic knowledge with other biomedical ontologies as part of the Semantic Web. © RSNA, 2014.

  14. Mobile technology in radiology resident education.

    PubMed

    Korbage, Aiham C; Bedi, Harprit S

    2012-06-01

    The authors hypothesized that ownership of a mobile electronic device would result in more time spent learning radiology. Current trends in radiology residents' studying habits, their use of electronic and printed radiology learning resources, and how much of the funds allotted to them are being used toward printed vs electronic education tools were assessed in this study. A survey study was conducted among radiology residents across the United States from June 13 to July 5, 2011. Program directors listed in the Association of Program Directors in Radiology e-mail list server received an e-mail asking for residents to participate in an online survey. The questionnaire consisted of 12 questions and assessed the type of institution, the levels of training of the respondents, and book funds allocated to residents. It also assessed the residents' study habits, access to portable devices, and use of printed and electronic radiology resources. Radiology residents are adopters of new technologies, with 74% owning smart phones and 37% owning tablet devices. Respondents spend nearly an equal amount of time learning radiology from printed textbooks as they do from electronic resources. Eighty-one percent of respondents believe that they would spend more time learning radiology if provided with tablet devices. There is considerable use of online and electronic resources and mobile devices among the current generation of radiology residents. Benefits, such as more study time, may be obtained by radiology programs that incorporate tablet devices into the education of their residents. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  15. Summary of the proceedings of the International Forum 2017: "Position of interventional radiology within radiology".

    PubMed

    2018-04-01

    The International Forum is held once a year by the ESR and its international radiological partner societies with the aim to address and discuss selected topics of global relevance in radiology. In 2017, the issue of the position of interventional radiology (IR) within radiology was analysed. IR is expanding because of the increased patient demand for minimally invasive therapies performed under imaging guidance, and its success in improving patient outcomes, reducing in-hospital stays, reducing morbidity and mortality of treatment in many organs and organ-systems. Despite the many successes of IR, public awareness about it is quite low. IR requires specific training and, in most countries, the majority of interventional radiologists do not dedicate their time completely to IR but perform diagnostic radiology investigations as well. Turf battles in IR are common in many countries. To preserve and keep IR within radiology, it is necessary to focus more on direct and longitudinal patient care. Having beds dedicated to IR within radiology departments is very important to increase clinical involvement of interventional radiologists. IR procedures fit perfectly within "value-based healthcare", but the metrics have to be developed. • IR should stay a prominent subspecialty within radiology. • Dedicated IR training pathways are mandatory. • Measures to increase recruitment of young doctors to IR and to increase public awareness of IR are needed. • Beds dedicated to IR within radiology departments are important in order to increase clinical involvement of interventional radiologists.

  16. [A CASE OF DEXTRANOMER-HYALURONIC ACID COPOLYMER (Deflux®) IMPLANTS CALCIFICATION MIMICKING DISTAL URETERAL CALCULI].

    PubMed

    Matsumoto, Fumi; Matsui, Futoshi; Yazawa, Koji; Shimada, Kenji

    2017-01-01

    Since 2011, endoscopic correction of vesicoureteral reflux using dextranomer-hyaluronic acid copolymer (Deflux ® ) has been widely accepted in Japan due to its safety and minimally invasive nature. However, long-term complications are unknown. We present a case of Deflux ® implants calcification mimicking distal ureteral calculi in a 12-year-old boy with a history of Deflux ® injection performed at three years of age for primary VUR. We should be aware of this complication to avoid misdiagnosis and unnecessary invasive examination such as radiological imaging or endoscopy.

  17. 2015 RAD-AID Conference on International Radiology for Developing Countries: The Evolving Global Radiology Landscape.

    PubMed

    Kesselman, Andrew; Soroosh, Garshasb; Mollura, Daniel J

    2016-09-01

    Radiology in low- and middle-income (developing) countries continues to make progress. Research and international outreach projects presented at the 2015 annual RAD-AID conference emphasize important global themes, including (1) recent slowing of emerging market growth that threatens to constrain the advance of radiology, (2) increasing global noncommunicable diseases (such as cancer and cardiovascular disease) needing radiology for detection and management, (3) strategic prioritization for pediatric radiology in global public health initiatives, (4) continuous expansion of global health curricula at radiology residencies and the RAD-AID Chapter Network's participating institutions, and (5) technologic innovation for recently accelerated implementation of PACS in low-resource countries. Published by Elsevier Inc.

  18. Breast reconstruction - implants

    MedlinePlus

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... it harder to find a tumor if your breast cancer comes back. Getting breast implants does not take ...

  19. Passive fit and accuracy of three dental implant impression techniques.

    PubMed

    Al Quran, Firas A; Rashdan, Bashar A; Zomar, AbdelRahman A Abu; Weiner, Saul

    2012-02-01

    To reassess the accuracy of three impression techniques relative to the passive fit of the prosthesis. An edentulous maxillary cast was fabricated in epoxy resin with four dental implants embedded and secured with heat-cured acrylic resin. Three techniques were tested: closed tray, open tray nonsplinted, and open tray splinted. One light-cured custom acrylic tray was fabricated for each impression technique, and transfer copings were attached to the implants. Fifteen impressions for each technique were prepared with medium-bodied consistency polyether. Subsequently, the impressions were poured in type IV die stone. The distances between the implants were measured using a digital micrometer. The statistical analysis of the data was performed with ANOVA and a one-sample t test at a 95% confidence interval. The lowest mean difference in dimensional accuracy was found within the direct (open tray) splinted technique. Also, the one-sample t test showed that the direct splinted technique has the least statistical significant difference from direct nonsplinted and indirect (closed tray) techniques. All discrepancies were less than 100 Μm. Within the limitations of this study, the best accuracy of the definitive prosthesis was achieved when the impression copings were splinted with autopolymerized acrylic resin, sectioned, and rejoined. However, the errors associated with all of these techniques were less than 100 Μm, and based on the current definitions of passive fit, they all would be clinically acceptable.

  20. International classification of reliability for implanted cochlear implant receiver stimulators.

    PubMed

    Battmer, Rolf-Dieter; Backous, Douglas D; Balkany, Thomas J; Briggs, Robert J S; Gantz, Bruce J; van Hasselt, Andrew; Kim, Chong Sun; Kubo, Takeshi; Lenarz, Thomas; Pillsbury, Harold C; O'Donoghue, Gerard M

    2010-10-01

    To design an international standard to be used when reporting reliability of the implanted components of cochlear implant systems to appropriate governmental authorities, cochlear implant (CI) centers, and for journal editors in evaluating manuscripts involving cochlear implant reliability. The International Consensus Group for Cochlear Implant Reliability Reporting was assembled to unify ongoing efforts in the United States, Europe, Asia, and Australia to create a consistent and comprehensive classification system for the implanted components of CI systems across manufacturers. All members of the consensus group are from tertiary referral cochlear implant centers. None. A clinically relevant classification scheme adapted from principles of ISO standard 5841-2:2000 originally designed for reporting reliability of cardiac pacemakers, pulse generators, or leads. Standard definitions for device failure, survival time, clinical benefit, reduced clinical benefit, and specification were generated. Time intervals for reporting back to implant centers for devices tested to be "out of specification," categorization of explanted devices, the method of cumulative survival reporting, and content of reliability reports to be issued by manufacturers was agreed upon by all members. The methodology for calculating Cumulative survival was adapted from ISO standard 5841-2:2000. The International Consensus Group on Cochlear Implant Device Reliability Reporting recommends compliance to this new standard in reporting reliability of implanted CI components by all manufacturers of CIs and the adoption of this standard as a minimal reporting guideline for editors of journals publishing cochlear implant research results.

  1. From implant planning to surgical execution: an integrated approach for surgery in oral implantology.

    PubMed

    Chiarelli, Tommaso; Franchini, Federico; Lamma, Achille; Lamma, Evelina; Sansoni, Tommaso

    2012-03-01

    Using oral implantology software and transferring the preoperative planning into a stereolithographic model, prosthodontists can produce the related surgical guide. This procedure has some disadvantages: bone-supported stent invasiveness, lack of references due to scattering and non-negligible stereolithography cost. An alternative solution is presented that provides an ideal surgical stent (not invasive, precise, and cheap) as a result. This work focuses on the third phase of a fully 3D approach to oral implant planning, that starts by CT scanning a patient who wears a markers-equipped radiological stent, continues exploiting built-on-purpose preoperative planning software, and finishes producing the ideal surgical template. A 5-axes bur-equipped robot has been designed able to reproduce the milling vectors planned by the software. Software-robot interfacing has been achieved properly matching the stent reference frame and the software and robot coordinate systems. Invasiveness has been avoided achieving the surgical stent from the mucosa-supported radiological mask wax-up. Scattering is ignored because of the surgical stent independency from the bone structure radiography. Production cost has been strongly reduced by avoiding the stereolithographic model. Finally, software-robot interfacing precision has been validated comparing digitally a multi-marker base and its planning transfer. Average position and orientation errors (respectively 0.283 mm ± 0.073 mm and 1.798° ± 0.496°) were significantly better than those achieved using methods based on stereolithography (respectively, 1.45 mm ± 1.42 mm and 7.25° ± 2.67°, with a general best maximum translation discrepancy of about 1.1 mm). This paper describes the last step of a fully 3D approach in which implant planning can be done in a 3D environment, and the correct position, orientation and depth of the planned implants are easily computed and transferred to the surgical phase. Copyright

  2. Recognizing dying in terminal illness.

    PubMed

    Taylor, Paul M; Johnson, Miriam

    2011-08-01

    Recognizing dying in terminally ill patients is a complex clinical skill. This article outlines the approach to the decision, common difficulties encountered in patients with both malignant and non-malignant disease, and a simple approach to considering the question 'Is this patient dying?'

  3. 21 CFR 892.1980 - Radiologic table.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiologic table. 892.1980 Section 892.1980 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1980 Radiologic table. (a) Identification. A radiologic...

  4. Die singulation method and package formed thereby

    DOEpatents

    Anderson, Robert C [Tucson, AZ; Shul, Randy J [Albuquerque, NM; Clews, Peggy J [Tijeras, NM; Baker, Michael S [Albuquerque, NM; De Boer, Maarten P [Albuquerque, NM

    2012-08-07

    A method is disclosed for singulating die from a substrate having a sacrificial layer and one or more device layers, with a retainer being formed in the device layer(s) and anchored to the substrate. Deep Reactive Ion Etching (DRIE) etching of a trench through the substrate from the bottom side defines a shape for each die. A handle wafer is then attached to the bottom side of the substrate, and the sacrificial layer is etched to singulate the die and to form a frame from the retainer and the substrate. The frame and handle wafer, which retain the singulated die in place, can be attached together with a clamp or a clip and to form a package for the singulated die. One or more stops can be formed from the device layer(s) to limit a sliding motion of the singulated die.

  5. Radiological Defense. Textbook.

    ERIC Educational Resources Information Center

    Defense Civil Preparedness Agency (DOD), Washington, DC.

    This textbook has been prepared under the direction of the Defense Civil Preparedness Agency (DCPA) Staff College for use as a student reference manual in radiological defense (RADEF) courses. It provides much of the basic technical information necessary for a proper understanding of radiological defense and summarizes RADEF planning and expected…

  6. Precision of fit between implant impression coping and implant replica pairs for three implant systems.

    PubMed

    Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser

    2013-01-01

    The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for

  7. Dying: A universal human experience?

    PubMed

    Bregman, L

    1989-03-01

    This paper explores the question, "Is there a universal psychological experience suffered by all dying persons?" a question to which the popular theory of Kübler-Ross presupposes an affirmative answer. Our answer takes three steps: first, a comparison between the Kübler-Ross model of dying and that of the late medievalBook of the Craft of Dying centered upon the five Kübler-Ross "stages"; second, a philosophical critique of the terms of this comparison; and third, a revised look at the alleged similarities between the two models, providing a deeper look at the moral and spiritual assumptions behind each.

  8. Historical Radiological Event Monitoring

    EPA Pesticide Factsheets

    During and after radiological events EPA's RadNet monitors the environment for radiation. EPA monitored environmental radiation levels during and after Chernobyl, Fukushima and other international and domestic radiological incidents.

  9. Strategic planning in radiology.

    PubMed

    Gill, Ileana E; Ondategui-Parra, Silvia; Nathanson, Eric; Seiferth, Jeremy; Ros, Pablo R

    2005-04-01

    As radiology continues to evolve and grow, radiologists must be concerned with preparing radiology for the future. Decisions in capital investments, mergers, outpatient diagnostic clinics, and payment and liability issues will require practicing radiologists to develop and follow up managerial, interpersonal, and learning skills that were not as necessary in the past. To become adept in the new radiology environment and be able to manage change and deal with difficult decisions, radiologists need to acquire a background in strategy.

  10. Induction for Radiology Patients

    NASA Astrophysics Data System (ADS)

    Yıldırım, Pınar; Tolun, Mehmet R.

    This paper represents the implementation of an inductive learning algorithm for patients of Radiology Department in Hacettepe University hospitals to discover the relationship between patient demographics information and time that patients spend during a specific radiology exam. ILA has been used for the implementation which generates rules and the results are evaluated by evaluation metrics. According to generated rules, some patients in different age groups or birthplaces may spend more time for the same radiology exam than the others.

  11. ["Good dying"--definition and current state of research].

    PubMed

    Hutter, Nico; Stößel, Ulrich; Meffert, Cornelia; Körner, Mirjam; Bozzaro, Claudia; Becker, Gerhild; Baumeister, Harald

    2015-08-01

    The advances of modern medicine did not only result in prolongation of life expectancy, but also led to a shift from dying at home to dying in public institutions. In western countries most people die at advanced age in medical facilities. Hence, the question regarding the conditions, which should be provided by society and especially medicine, to allow terminally ill people to experience "good dying" is substantial. For this purpose, an examination of patients', family members' and health care providers' understanding of the term " good dying" is required. The present paper aims at shedding light on the term "good dying" and to summarize the current state of research. Therefore, the attributes of "good dying" will be described from the perspectives of patients, family members and health care providers, which are discussed and examined in current medical-sociological research. These attributes can be illustrated on three dimensions: Quality of life at the end of life (e. g. pain relief, mental well-being), quality of dying (e. g. avoiding prolonged dying, autonomy, presence of relatives) and quality of health care at the end of life (e. g. patient-oriented health care, positive communication between health care providers and patients, availability of guidelines). Although the attributes of "good dying" are described in detail in the existing literature, further studies have to clarify the relevance and impact of these attributes as predictors of "good dying". © Georg Thieme Verlag KG Stuttgart · New York.

  12. Bereits nach Ablauf der Halbwertszeit droht der vollständige Zerfall Die britische Atomic Scientists’ Association, die Ideologie der „objektiven” Wissenschaft und die H-Bombe

    NASA Astrophysics Data System (ADS)

    Laucht, Christoph

    Präsident Harry Trumans Verlautbarung vom 31.1.1950, seine Regierung wolle die Entwicklung der Wasserstoffbombe vorantreiben, fand große Beachtung in den britischen Medien. Die illustrierte Zeitschrift Picture Post widmete der HBombe einen Artikel, der unter anderem kurze Stellungnahmen der britischen Atomwissenschaftler Eric Burhop, Kathleen Lonsdale, Harrie Massey, Rudolf Peierls und Maurice Pryce enthielt, die alle Mitglieder der Atomic Scientists' Association (ASA) waren.

  13. [Application of plasma sprayed zirconia coating in dental implant: study in implant].

    PubMed

    Huang, Z F; Wang, Z F; Li, C H; Hao, D; Lan, J

    2018-04-09

    Objective: To investigate the osseointegration of a novel coating-plasma-sprayed zirconia in dental implant. Methods: Zirconia coating on non-thread titanium implant was prepared using plasma spraying, the implant surface morphology, surface roughness and wettability were measured. In vivo , zirconia coated implants were inserted in rabbit tibia and animals were respectively sacrificed at 2, 4, 8 and 12 weeks after implantation. The bond strength between implant and bone was measured by push-out test. The osseointegration was observed by scanning electron microscopy (SEM), micro CT and histological analyses. Quantified parameters including removal torque, and bone-implant contact (BIC) percentage were calculated. Results: The surface roughness (1.6 µm) and wettability (54.6°) of zirconia coated implant was more suitable than those of titanium implant (0.6 µm and 74.4°) for osseointegration. At 12 weeks, the push-out value of zirconia coated implant and titanium implant were (64.9±3.0) and (50.4±2.9) N, and BIC value of these two groups were (54.7±3.6)% and (41.5±3.6)%. All these differences had statistical significance. Conclusions: The surface characters of zirconia coated implant were more suitable for osseointegration and present better osseointegration than smooth titanium implant in vivo , especially at early stage.

  14. Radiology's value chain.

    PubMed

    Enzmann, Dieter R

    2012-04-01

    A diagnostic radiology value chain is constructed to define its main components, all of which are vulnerable to change, because digitization has caused disaggregation of the chain. Some components afford opportunities to improve productivity, some add value, while some face outsourcing to lower labor cost and to information technology substitutes, raising commoditization risks. Digital image information, because it can be competitive at smaller economies of scale, allows faster, differential rates of technological innovation of components, initiating a centralization-to-decentralization technology trend. Digitization, having triggered disaggregation of radiology's professional service model, may soon usher in an information business model. This means moving from a mind-set of "reading images" to an orientation of creating and organizing information for greater accuracy, faster speed, and lower cost in medical decision making. Information businesses view value chain investments differently than do small professional services. In the former model, producing a better business product will extend image interpretation beyond a radiologist's personal fund of knowledge to encompass expanding external imaging databases. A follow-on expansion with integration of image and molecular information into a report will offer new value in medical decision making. Improved interpretation plus new integration will enrich and diversify radiology's key service products, the report and consultation. A more robust, information-rich report derived from a "systems" and "computational" radiology approach will be facilitated by a transition from a professional service to an information business. Under health care reform, radiology will transition its emphasis from volume to greater value. Radiology's future brightens with the adoption of a philosophy of offering information rather than "reads" for decision making. Staunchly defending the status quo via turf wars is unlikely to constitute a

  15. Cochlear implantation in late-implanted adults with prelingual deafness.

    PubMed

    Most, Tova; Shrem, Hadas; Duvdevani, Ilana

    2010-01-01

    The purpose of this study was to examine the effect of cochlear implantation (CI) on prelingually deafened participants who were implanted as adults. The effect of the CI was examined with regard to the following variables: communication, family, social skills, education, and work satisfaction with one's life, loneliness, and self-esteem. Thirty-eight adults participated. Four self-report questionnaires were used at 2 points in time: before and after CI. The research findings show significant differences in the reports of most variables before and after implantation. The participants felt better with regard to communication, social skills, education, and work and satisfaction with one's life after implantation in comparison to their feelings before implantation. Furthermore, they felt less lonely after implantation. However, there were no significant differences before and after implantation regarding their feelings within the family and regarding their self-esteem. The results demonstrated the need to evaluate the benefits resulting from the CI not only with traditional clinical measures but with additional measures as well. Furthermore, they demonstrated the benefit of the CI on the positive psychosociological implications of prelingually deafened adults. Copyright © 2010 Elsevier Inc. All rights reserved.

  16. Die Deformation Measurement System during Sheet Metal Forming

    NASA Astrophysics Data System (ADS)

    Funada, J.; Takahashi, S.; Fukiharu, H.

    2011-08-01

    In order to reduce affection to the earth environment, it is necessary to lighten the vehicles. For this purpose, high tensile steels are applied. Because of high strength, high forming force is required for producing automotive sheet metal parts. In this situation, since the dies are elastic, they are deformed during forming parts. For reducing die developing period, sheet metal forming simulation is widely applied. In the numerical simulation, rigid dies are usually used for shortening computing time. It means that the forming conditions in the actual forming and the simulation are different. It will make large errors in the results between actual forming and simulation. It can be said that if contact pressure between dies and a sheet metal in the simulation can be reproduced in the actual forming, the differences of forming results between them can also been reduced. The basic idea is to estimate die shape which can produce the same distribution as computed from simulation with rigid dies. In this study, die deformation analyses with Finite Element Method as basic technologies are evaluated. For example, simple shape and actual dies elastic contact problems were investigated. The contact width between simple shape dies was investigated. The computed solutions were in good agreement with experimental results. The one case of the actual dies in two cases was also investigated. Bending force was applied to the blank holder with a mechanical press machine. The methodology shown with applying inductive displacement sensor for measuring die deformation during applying force was also proposed.

  17. Prevalence of peri-implantitis in patients with implant-supported fixed prostheses.

    PubMed

    Schuldt Filho, Guenther; Dalago, Haline Renata; Oliveira de Souza, João Gustavo; Stanley, Kyle; Jovanovic, Sascha; Bianchini, Marco Aurélio

    2014-01-01

    The purpose of this study was to evaluate periimplantitis prevalence in patients using implant-supported fixed prostheses that did not have any routine maintenance care. A total of 161 implants (27 patients) were evaluated in patients using implant-supported fixed prostheses. Collected data included information related to patient general health and local factors such as characteristics of implants, time in function, type of loading, positioning, Modified Bleeding Index, bacterial plaque, bleeding on probing (BOP), marginal recession, probing depth (PD), keratinized mucosa, and radiographic bone loss (BL). Factors related to the prostheses were also evaluated. The exclusion criteria were patients that have had any follow-up visit for plaque control of the prosthesis and/or the implants. From a total of 161 implants, 116 (72%) presented without peri-implantitis (PD > 4 mm + BOP + BL > 2 mm) while 45 (28%) had some sign of the disease. Implants placed in the maxilla were 2.98 times more likely to develop the disease (P < .05). Moreover, patients aged ≤ 60 years old were 3.24 times more likely to develop peri-implantitis (P < .05). Another analysis with statistical relevance (P < .05) was that implants with less than 3 mm interimplant distance were three times more likely to have peri-implantitis. There was no statistical relevance considering other analyses. It can be concluded that patients aged ≤ 60 years have a greater chance of presenting periimplantitis, as well as for implants positioned in the maxilla and those placed with an interimplant distance < 3 mm.

  18. [New biodegradable polylactide implants (Polypin-C) in therapy for radial head fractures].

    PubMed

    Prokop, A; Jubel, A; Helling, H J; Udomkaewkanjana, C; Brochhagen, H G; Rehm, K E

    2002-10-01

    Dislocated radial head fractures of the type Mason II are usually treated with screws and buttress plates. The implants are generally removed at a later date. Biodegradable implants can be applied successfully for the reduction of small radial head fractures subject to shearing forces and slight loads. The implants are completely absorbed once the fracture has healed, making a second operation for the removal of the implant unnecessary. The Polypin C-Pin is made of poly(L, DL-lactide) mixed with 10% beta-tricalcium phosphate to ensure controlled, slow degradation with no significant side effects. This new Polypin C fixation pin was clinically tested on 35 patients with radial head fractures (CCF 21B2.1 and 21B2.2) from 31.10.1996 until 1.4.2002. A total of 34 of the patients (97.1%) underwent a clinical and conventional radiological follow-up examination after an average of 38.2 months. In 29 cases a CT was also carried out. Between 18 and 24 months, two cases of grade 1 osteolysis were observed around the pin head. No trace of osteolysis was observed at the final examination in either case. According to the Broberg score, an average of 96 out of a possible 100 points were attained at the final examination (31 excellent, 2 good, 1 unsatisfactory). After a period of 24 months, the pins were no longer visible on a conventional x-ray. A CT evaluation showed a density similar to that of spongioid bone in the original pin cavities after 3 years. These excellent clinical results prove that the Polypin C is a good method to treat dislocated radial head fractures.

  19. Einführung in die Technische Chemie

    NASA Astrophysics Data System (ADS)

    Behr, Arno; Agar, David W.; Jörissen, Jakob

    Die "Technische Chemie" ist ein Lehrfach an Universitäten und Hochschulen. Nach dem die Studierenden der Chemie in den ersten Semestern ihres Studiums ausrei chen de theoretische Kenntnisse in Allgemeiner, Anorganischer, Organischer und Physikalischer Chemie erlangt haben, soll die Technische Chemie einen Blick auf die praktische Anwendung dieser Naturwissenschaft in unserer Wirtschaft lenken. Es gibt keine "biologische Industrie", "physikalische Industrie" oder "mathematische Industrie", wohl aber seit über 150 Jahren eine "chemische Industrie", die in dieser lan gen Zeit zahlreiche chemische Prozesse entwickelt und dazu vielfältige Methoden erarbeitet hat. Das Lehrfach Technische Chemie gibt einen Überblick über diese Pro zesse und Methoden und erleichtert dadurch den Schritt von der Universität zur be ruflichen Praxis.

  20. Prevalences of peri-implantitis and peri-implant mucositis: systematic review and meta-analysis.

    PubMed

    Lee, Chun-Teh; Huang, Yen-Wen; Zhu, Liang; Weltman, Robin

    2017-07-01

    Due to the inconsistent definitions, reporting methods and study characteristics, prevalences of peri-implant diseases significantly varied in studies. This study aimed to systematically analyze implant-based and subject-based prevalences of peri-implant diseases and assess clinical variables potentially affecting the prevalence. Electronic search of studies was conducted using MEDLINE (PubMed), EMBASE and Web of Science. Publication screening, data extraction, and quality assessment were performed. Clinical studies having an at least average three-year follow-up period were selected. The numbers of subjects and implants in the studies had to be equal to or more than thirty. Forty seven studies were selected and prevalences of peri-implant diseases were analyzed. Since heterogeneity existed in each outcome (I 2 =94.7, 95.7, 95.3, and 99.3 for implant-based and subject-based peri-implantitis and peri-implant mucositis, respectively), the random-effects model based on the DerSimonian and Laird method, which incorporate an estimate of heterogeneity in the weighting, was applied to obtain the pooled prevalence. Weighted mean implant-based and subject-based peri-implantitis prevalences were 9.25% (95% Confidence Interval (CI): [7.57, 10.93]) and 19.83% (CI [15.38, 24.27) respectively. Weighted mean implant-based and subject-based peri-implant mucositis prevalences were 29.48% (CI: [22.65, 36.32]) and 46.83% (CI: [38.30, 55.36]) respectively. Functional time and implant to subject ratio were associated with subject-based peri-implantitis prevalence, but not peri-implant mucositis prevalences. Peri-implant diseases were prevalent and prevalence of peri-implantitis increased over time. Prevalences of peri-implantitis and peri-implant mucositis might not be highly associated since the prevalences were influenced by distinct variables. The results should be carefully interpreted because of data heterogeneity. Peri-implant diseases affect a significant number of dental

  1. Decontamination of dental implant surface in peri-implantitis treatment: A literature review

    PubMed Central

    Buitrago-Vera, Pedro; Solá-Ruiz, María F.; Ferrer-García, Juan C.

    2013-01-01

    Etiological treatment of peri-implantitis aims to reduce the bacterial load within the peri-implant pocket and decontaminate the implant surface in order to promote osseointegration. The aim of this literature review was to evaluate the efficacy of different methods of implant surface decontamination. A search was conducted using the PubMed (Medline) database, which identified 36 articles including in vivo and in vitro studies, and reviews of different decontamination systems (chemical, mechanical, laser and photodynamic therapies). There is sufficient consensus that, for the treatment of peri-implant infections, the mechanical removal of biofilm from the implant surface should be supplemented by chemical decontamination with surgical access. However, more long-term research is needed to confirm this and to establish treatment protocols responding to different implant characterics. Key words:Peri-implantitis, treatment, decontamination, implant surface, laser. PMID:23986023

  2. Outcomes of ventricular assist device implantation in children and young adults: the Melbourne experience.

    PubMed

    Shi, William Y; Marasco, Silvana F; Saxena, Pankaj; d'Udekem, Yves; Yong, Matthew S; Mitnovetski, Sergei; Brizard, Christian P; McGiffin, David C; Weintraub, Robert G; Konstantinov, Igor E

    2016-12-01

    We evaluated our experience with ventricular assist device (VAD) implantation in children and young adults. A total of 64 patients underwent VAD implantation in two centres. The mean age was 15 ± 7.2 years. Thirty-five (55%) patients were under 18 years of age. Devices implanted included the Thoratec Paracorporeal in 30 (47%) patients, Berlin Heart EXCOR in 11 (17%) and VentrAssist in 14 (22%). The diagnosis was cardiomyopathy in 53, congenital heart disease in 11, and graft failure in four patients. There were 10 (16%) in-hospital deaths. Mortality was higher in patients <18 years of age (26% compared with 3.4% for those ≥18 years, P = 0.02). The use of extracorporeal membrane oxygenation prior to VAD implantation was associated with higher mortality (P = 0.006). Seventeen (27%) patients experienced stroke. Nine patients (14%) required change of VAD because of thrombosis. Transplantation was performed in 44 patients after a mean of 131 ± 141 days on VAD, 11 patients died without transplantation and three patients currently await transplantation. The VAD was explanted in six patients because of recovery. Overall survival from VAD implantation was 69% and 61% at 5 and 10 years, respectively. The 5-year post-transplant survival for those bridged with VAD support was 91% and was comparable with a cohort of patients who did not receive a pre-transplant VAD. Children requiring pre-transplant VAD support have a higher mortality and morbidity compared with young adults. Survival after heart transplantation those supported with VADs was similar to patients of similar age who did not require pre-transplant support. © 2015 Royal Australasian College of Surgeons.

  3. The natural history of new-onset heart failure with a severely depressed left ventricular ejection fraction: implications for timing of implantable cardioverter-defibrillator implantation.

    PubMed

    Teeter, William A; Thibodeau, Jennifer T; Rao, Krishnasree; Brickner, M Elizabeth; Toto, Kathleen H; Nelson, Lauren L; Mishkin, Joseph D; Ayers, Colby R; Miller, Justin G; Mammen, Pradeep P A; Patel, Parag C; Markham, David W; Drazner, Mark H

    2012-09-01

    Guidelines recommend that patients with new-onset systolic heart failure (HF) receive a trial of medical therapy before an implantable cardiac defibrillator (ICD). This strategy allows for improvement of left ventricular ejection fraction (LVEF), thereby avoiding an ICD, but exposes patients to risk of potentially preventable sudden cardiac death during the trial of medical therapy. We reviewed a consecutive series of patients with HF of <6 months duration with a severely depressed LVEF (<30%) evaluated in a HF clinic (N = 224). The ICD implantation was delayed with plans to reassess LVEF approximately 6 months after optimization of β-blockers. Mortality was ascertained by the National Death Index. Follow-up echocardiograms were performed in 115 of the 224 subjects. Of these, 50 (43%) had mildly depressed or normal LVEF at follow-up ("LVEF recovery") such that an ICD was no longer indicated. In a conservative sensitivity analysis (using the entire study cohort, whether or not a follow-up echocardiogram was obtained, as the denominator), 22% of subjects had LVEF recovery. Mortality at 6, 12, and 18 months in the entire cohort was 2.3%, 4.5%, and 6.8%, respectively. Of 87 patients who tolerated target doses of β-blockers, only 1 (1.1%) died during the first 18 months. Patients with new-onset systolic HF have both a good chance of LVEF recovery and low 6-month mortality. Achievement of target β-blocker dose identifies a very low-risk population. These data support delaying ICD implantation for a trial of medical therapy. Copyright © 2012 Mosby, Inc. All rights reserved.

  4. Two-stage implant systems.

    PubMed

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  5. Minimally invasive surgical implantation of left ventricular epicardial leads for ventricular resynchronization using video-assisted thoracoscopy.

    PubMed

    Fernández, Angel L; García-Bengochea, José B; Ledo, Ramiro; Vega, Marino; Amaro, Antonio; Alvarez, Julián; Rubio, José; Sierra, Juan; Sánchez, Daniel

    2004-04-01

    Cardiac resynchronization via left ventricular or biventricular pacing is an option for selected patients with ventricular systolic dysfunction and widened QRS complex. Stimulation through a coronary vein is the technique of choice for left ventricular pacing, but this approach results in a failure rate of approximately 8%. We describe our initial experience with minimally invasive surgical implantation of left ventricular epicardial leads using video-assisted thoracoscopy. A total of 14 patients with congestive heart failure, NYHA functional class 3.2 (0.6) and mean ejection fraction 22.9 (6.8)% were included in this study. Left bundle branch block, QRS complex >140 ms and abnormal septal motion were observed in all cases. Epicardial leads were implanted on the left ventricular free wall under general anesthesia using video-assisted thoracoscopic surgery. Lead implantation was successful in 13 patients. Conversion to a small thoracotomy was necessary in one patient. All patients were extubated in the operating room. None of the patients died during their hospital stay. Follow-up showed reversal of ventricular asynchrony and significant improvement in ejection fraction and functional class. Minimally invasive surgery for ventricular resynchronization using video-assisted thoracoscopy in selected patients is a safe procedure that makes it possible to choose the best site for lead implantation and provides adequate short- and medium-term stimulation.

  6. Implant-level prostheses in the edentulous maxilla: a comparison with conventional abutment-level prostheses after 5 years of use.

    PubMed

    Hjalmarsson, Lars; Smedberg, Jan-Ivan; Pettersson, Mattias; Jemt, Torsten

    2011-01-01

    Long-term comparisons of frameworks at the implant or abutment level are not available, and knowledge of the clinical function of cobalt-chromium (Co-Cr) alloy frameworks is limited. Primarily, the aim of this study was to compare the 5-year clinical performance of frameworks with or without abutment connections to implants. Secondly, the outcomes of prostheses made from Co-Cr alloy with porcelain veneers to those made of commercially pure titanium (CP Ti) with acrylic veneers were compared. The test groups comprised patients treated with screw-retained fixed prostheses made at the implant level according to the Cresco method in either dental porcelain-veneered Co-Cr alloy (n = 15) or acrylic-veneered CP Ti (n = 25). A control group of 40 randomly selected patients were provided with prostheses made at the standard abutment level in CP Ti with acrylic veneers. For all patients, clinical and radiologic 5-year data were retrospectively collected and evaluated. Five-year implant cumulative survival rates (CSRs) were 98.6% and 97.6% for test and control groups, respectively (P > .05). No major differences in bone level were demonstrated between the groups after 5 years (P > .05). Significantly more complications occurred in the test groups compared to the control group (P < .01), with the most common complications being mucositis and fracture of veneers. After 5 years, the clinical outcomes of implant-level prostheses made of porcelain-veneered Co-Cr or acrylic-veneered CP Ti seem comparable to acrylic-veneered titanium prostheses made at the standard abutment level regarding implant CSR and bone levels. However, more complications were registered in implant-level prostheses compared to the standard abutment-level prostheses.

  7. Implant decontamination with phosphoric acid during surgical peri-implantitis treatment: a RCT.

    PubMed

    Hentenaar, Diederik F M; De Waal, Yvonne C M; Strooker, Hans; Meijer, Henny J A; Van Winkelhoff, Arie-Jan; Raghoebar, Gerry M

    2017-12-01

    Peri-implantitis is known as an infectious disease that affects the peri-implant soft and hard tissue. Today, scientific literature provides very little evidence for an effective intervention protocol for treatment of peri-implantitis. The aim of the present randomized controlled trial is to evaluate the microbiological and clinical effectiveness of phosphoric acid as a decontaminating agent of the implant surface during surgical peri-implantitis treatment. Peri-implantitis lesions were treated with resective surgical treatment aimed at peri-implant granulation tissue removal, bone recontouring, and pocket elimination. Fifty-three implant surfaces in 28 patients were mechanically cleaned and treated with either 35% phosphoric etching gel (test group) or sterile saline (control group). Microbiological samples were obtained during surgery; clinical parameters were recorded at baseline and at 3 months after treatment. Data were analyzed using multi-variable linear regression analysis and multilevel statistics. Significant immediate reductions in total anaerobic bacterial counts on the implant surface were found in both groups. Immediate reduction was greater when phosphoric acid was used. The difference in log-transformed mean anaerobic counts between both procedures was not statistical significant (p = 0.108), but there were significantly less culture-positive implants after the decontamination procedure in the phosphoric acid group (p = 0.042). At 3 months post-surgery, 75% of the implants in the control group and 63.3% of the implants in the test group showed disease resolution. However, no significant differences in clinical and microbiological outcomes between both groups were found. The application of 35% phosphoric acid after mechanical debridement is superior to mechanical debridement combined with sterile saline rinsing for decontamination of the implant surface during surgical peri-implantitis treatment. However, phosphoric acid as implant surface

  8. Chemical, corrosion and topographical analysis of stainless steel implants after different implantation periods.

    PubMed

    Chrzanowski, Wojciech; Armitage, David Andrew; Knowles, Jonathan Campbell; Szade, Jacek; Korlacki, Wojciech; Marciniak, Jan

    2008-07-01

    The aim of this work is to examine the corrosion properties, chemical composition, and material-implant interaction after different periods of implantation of plates used to correct funnel chest. The implants are made of 316L stainless steel. Examinations are carried out on three implants: new (nonimplanted) and two implanted for 29 and 35 months. The corrosion study reveals that in the potential range that could occur in the physiological condition the new bar has the lowest current density and the highest corrosion potential. This indicates that the new plate has the highest corrosion resistance and the corrosion resistance could be reduced during implantation by the instruments used during the operation. XPS analysis reveals changes in the surface chemistry. The longer the implantation time the more carbon and oxygen are observed and only trace of elements such as Cr, Mo are detected indicating that surface is covered by an organic layer. On some parts of the implants whitish tissue is observed: the thickness of which increased with the time of implantation. This tissue was identified as an organic layer; mainly attached to the surface on the areas close to where the implant was bent to attain anatomical fit and thus where the implant has higher surface roughness. The study indicates that the chest plates are impaired by the implantation procedure and contact with biological environment. The organic layer on the surface shows that the implant did not stay passive but some reactions at the tissue-implant interface occurred. These reactions should be seen as positive, as it indicates that the implants were accepted by the tissues. Nevertheless, if the implants react, they may continue to release chromium, nickel, and other harmful ions long term as indicated by lower corrosion resistance of the implants following implantation.

  9. Impact of implant design on primary stability of orthodontic mini-implants.

    PubMed

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  10. Clinical Performance of One-Piece, Screw-Retained Implant Crowns Based on Hand-Veneered CAD/CAM Zirconia Abutments After a Mean Follow-up Period of 2.3 Years.

    PubMed

    Schnider, Nicole; Forrer, Fiona Alena; Brägger, Urs; Hicklin, Stefan Paul

    The aim of this study was to evaluate the clinical performance of one-piece, screw-retained implant crowns based on hand-veneered computer-aided design/computer-aided manufacture (CAD/CAM) zirconium dioxide abutments with a crossfit connection at least 1 year after insertion of the crown. Consecutive patients who had received at least one Straumann bone level implant and one-piece, screw-retained implant crowns fabricated with CARES zirconium dioxide abutments were reexamined. Patient satisfaction, occlusal and peri-implant parameters, mechanical and biologic complications, radiologic parameters, and esthetics were recorded. A total of 50 implant crowns in the anterior and premolar region were examined in 41 patients. The follow-up period of the definitive reconstructions ranged from 1.1 to 3.8 years. No technical and no biologic complications had occurred. At the reexamination, 100% of the implants and reconstructions were in situ. Radiographic evaluation revealed a mean distance from the implant shoulder to the first visible bone-to-implant contact of 0.06 mm at the follow-up examination. Screw-retained crowns based on veneered CAD/CAM zirconium dioxide abutments with a crossfit connection seem to be a promising way to replace missing teeth in the anterior and premolar region. In the short term, neither failures of components nor complications were noted, and the clinical and radiographic data revealed stable hard and soft tissue conditions.

  11. Surgical and immediate postrelease mortality of harlequin ducks (Histrionicus histrionicus) implanted with abdominal radio transmitters with percutaneous antennae

    USGS Publications Warehouse

    Mulcahy, Daniel M.; Esler, Daniel N.

    1999-01-01

    Radiotelemetry is an essential tool in the study of free-ranging bird populations, and a variety of transmitter-attachment methods have been developed. A promising new method is abdominal implantation of a transmitter with a percutaneous antenna. Researchers using this technique should be concerned about and aware of mortality during surgery and during the immediate postrelease period (the 14-day period following surgery). Of 307 radio-implant surgeries performed between 1995 and 1997 in harlequin ducks (Histrionicus histrionicus), 7 (2.3%) deaths were documented during surgery or anesthetic recovery. Of 295 birds released with implanted radios, 10 (3.4%) died during the immediate postrelease period. Modifications to anesthetic procedures used in the 204 surgeries performed in 1996 and 1997 reduced mortality to 1.5% during surgery and 1.5% during the immediate postrelease period. Anesthetic modifications included intubation of all birds, placement of birds on an elevated platform that allowed the head to rest at a level lower than the body during surgery, placement of a heated water blanket under the birds during surgery, monitoring of body temperature, and use of electrocardiogram and Doppler ultrasound to monitor heart rates and arrhythmias. Low levels of mortality associated with abdominal implantation of radio transmitters may be unavoidable, but mortality can be minimized with adjustments to anesthetic technique.

  12. Relation between total shock energy and mortality in patients with implantable cardioverter-defibrillator.

    PubMed

    Tenma, Taro; Yokoshiki, Hisashi; Mitsuyama, Hirofumi; Watanabe, Masaya; Mizukami, Kazuya; Kamada, Rui; Takahashi, Masayuki; Sasaki, Ryo; Maeno, Motoki; Okamoto, Kaori; Chiba, Yuki; Anzai, Toshihisa

    2018-05-15

    Implantable Cardioverter-Defibrillator (ICD) shocks have been associated with mortality. However, no study has examined the relation between total shock energy and mortality. The aim of this study is to assess the association of total shock energy with mortality, and to determine the patients who are at risk of this association. Data from 316 consecutive patients who underwent initial ICD implantation in our hospital between 2000 and 2011 were retrospectively studied. We collected shock energy for 3 years from the ICD implantation, and determined the relation of shock energy on mortality after adjusting confounding factors. Eighty-seven ICD recipients experienced shock(s) within 3 years from ICD implantation and 43 patients had died during the follow-up. The amount of shock energy was significantly associated with all-cause death [adjusted hazard ratio (HR) 1.26 (per 100 joule increase), p < 0.01] and tended to be associated with cardiac death (adjusted HR 1.30, p = 0.08). The survival rate of patients with high shock energy accumulation (≥182 joule) was lower (p < 0.05), as compared to low shock energy accumulation (<182 joule), likewise to no shock. Besides, the relation between high shock energy accumulation and all-cause death was remarkable in the patients with low left ventricular ejection fraction (LVEF ≤40%) or atrial fibrillation (AF). Increase of shock energy was related to mortality in ICD recipients. This relation was evident in patients with low LVEF or AF. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Distortion of three-unit implant frameworks during casting, soldering, and simulated porcelain firings.

    PubMed

    Zervas, P J; Papazoglou, E; Beck, F M; Carr, A B

    1999-09-01

    The aim of this study was to assess distortion inherent in casting, soldering, and simulated porcelain firings of screw-retained, implant-supported three-unit fixed partial dentures (FPDs). Ten wax patterns were fabricated on a die-stone cast containing two implants, 20 mm apart from center to center. Five specimens were cast in a high-palladium alloy, exposed to simulated porcelain firings, sectioned, and then soldered with low-fusing solder. Five specimens were cast, sectioned, soldered with high-fusing solder, and then exposed to simulated porcelain firings. For each specimen, two horizontal and six vertical distances between appropriately scribed reference points were measured with a traveling microscope. Comparisons were made among the various measurements taken after wax-pattern fabrication, casting, high- and low-fusing soldering, and each porcelain firing. Data were analyzed using a repeated-measures factorial ANOVA (alpha = 0.05). Significant difference was detected in the amount of horizontal distortion during casting (53 +/- 24 microns) and high-fusing soldering (-49 +/- 50 microns), as well as in the amount of horizontal distortion during high-fusing soldering (-49 +/- 50 microns) and low-fusing soldering (17 +/- 26 microns). However, no clinically significant difference was found in the amount of horizontal distortion during casting, low-fusing, and high-fusing soldering. The greatest amount of distortion during the simulated porcelain firings took place during the oxidizing cycle. Soldering did not improve the casting misfit of a three-unit implant-retained FPD model. Metal-ceramic implant frameworks should be oxidized before intraoral fit evaluation.

  14. Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis.

    PubMed

    Hong, Hae Ryong; Pae, Ahran; Kim, Yooseok; Paek, Janghyun; Kim, Hyeong-Seob; Kwon, Kung-Rock

    2012-01-01

    The aim of this study was to analyze and compare the level and distribution of peri-implant bone stresses associated with mandibular two-implant overdentures with different implant positions. Mathematical models of mandibles and overdentures were designed using finite element analysis software. Two intraosseous implants and ball attachment systems were placed in the interforaminal region. The overdenture, which was supported by the two implants, was designed to withstand bilateral and unilateral vertical masticatory loads (total 100 N). In all, eight types of models, which differed according to assigned implant positions, height of attachments, and angulation, were tested: MI (model with implants positioned in the lateral incisor sites), MC (implants in canine sites), MP (implants in premolar sites), MI-Hi (greater height of attachments), MC-M (canine implants placed with mesial inclination), MC-D (canine implants placed with distal inclination), MC-B (canine implants placed with buccal inclination), and MC-L (canine implants placed with lingual inclination). Peri-implant bone stress levels associated with overdentures retained by lateral incisor implants resulted in the lowest stress levels and the highest efficiency in distributing peri-implant stress. MI-Hi showed increased stress levels and decreased efficiency in stress distribution. As the implants were inclined, stress levels increased and the efficiency of stress distribution decreased. Among the inclined models, MC-B showed the lowest stress level and best efficiency in stress distribution. The lowest stress and the best stability of implants in mandibular two-implant overdentures were obtained when implants were inserted in lateral incisor areas with shorter attachments and were placed parallel to the long axes of the teeth.

  15. Interventional Radiology in Paediatrics.

    PubMed

    Chippington, Samantha J; Goodwin, Susie J

    2015-01-01

    As in adult practice, there is a growing role for paediatric interventional radiology expertise in the management of paediatric pathologies. This review is targeted for clinicians who may refer their patients to paediatric interventional radiology services, or who are responsible for patients who are undergoing paediatric interventional radiology procedures. The article includes a brief overview of the indications for intervention, techniques involved and the commonest complications. Although some of the procedures described are most commonly performed in a tertiary paediatric centre, many are performed in most Children's hospitals.

  16. Radiologic technology educators and andragogy.

    PubMed

    Galbraith, M W; Simon-Galbraith, J A

    1984-01-01

    Radiologic technology educators are in constant contact with adult learners. However, the theoretical framework that radiologic educators use to guide their instruction may not be appropriate for adults. This article examines the assumptions of the standard instructional theory and the most modern approach to adult education-- andragogy . It also shows how these assumptions affect the adult learner in a radiologic education setting.

  17. 25 CFR 301.4 - Application of dies.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Application of dies. 301.4 Section 301.4 Indians INDIAN ARTS AND CRAFTS BOARD, DEPARTMENT OF THE INTERIOR NAVAJO, PUEBLO, AND HOPI SILVER AND TURQUOISE PRODUCTS; STANDARDS § 301.4 Application of dies. Dies are to be applied to the object with the aid of...

  18. A prospective randomized study on the immediate loading of mandibular overdentures supported by one or two implants; a 3 year follow-up report.

    PubMed

    Kronstrom, Mats; Davis, Ben; Loney, Robert; Gerrow, Jack; Hollender, Lars

    2014-06-01

    The objective of the study was to evaluate and compare treatments with mandibular overdentures supported by one or two immediately placed implants 3 years after loading. Thirty-six edentulous subjects were eligible for inclusion. Using a random sampling system, one or two implants were placed in the mandible. Separate ball attachments were connected to the implants, and the denture was relined and delivered the day of surgery with the retentive components incorporated in the denture base. At the follow-up examinations peri-implant bone levels, implant and denture stability/retention, and need for maintenance and adjustments were evaluated. Moreover, the OHIP-EDENT questionnaire was used to measure patient satisfaction. Nineteen subjects (10 men and 9 women) with a mean age of 56 years were available for the 3-year follow-up examination. The group with 1 implant (Group 1) consisted of 11 subjects (5 women and 6 men) while the remaining 8 (5 women and 3 men) belonged to Group2. Nine subjects had been excluded during the first year due to failing implants, 6 had moved, 1 had died, and 1 reported severe illness. No implant failures between the 12-and 36 month follow-up were observed. The mean peri-implant bone change was.86 mm and the Implant Stability Quotient showed only minor changes with no significant difference between the groups when compared with the 12-month follow-up. Patient satisfaction scores increased significantly when compared with the baseline values and continued to be high for both groups and need for denture maintenance was low. No significant differences were found between subjects in the two groups with respect to implant survival and peri implant bone loss, and patient satisfaction scores continued to be high for both groups. Need for denture maintenance was low in both groups. © 2012 Wiley Periodicals, Inc.

  19. Nursing students' experiences caring for dying patients.

    PubMed

    Beck, C T

    1997-11-01

    Since the 1960s nurse educators have been searching for the most effective approach to prepare nursing students for care of the dying. Studies investigating the effectiveness of death education programs for nursing students have reported inconsistent findings. A phenomenological study was conducted to explore the meaning of 26 undergraduate nursing students' experiences in caring for dying patients. The nursing students' written descriptions of their experiences were analyzed using Colaizzi's (1978) phenomenological method. Six themes emerged from this analysis. While caring for dying patients, nursing students experienced a gamut of emotions such as fear, sadness, frustration, and anxiety. Contemplation of the patient's life and death occurred as the students cared for their patients. In addition to providing physical, emotional, and spiritual support for dying patients, an integral part of nursing students' care involved supporting the patients' families. Helplessness was experienced by the students regarding their role as patient advocates. While caring for dying patients, nursing students' learning fluorished. Educational strategies for preparing nursing students to care for the dying are addressed based on the findings of this qualitative study.

  20. Der Einfluss der Digitalisierung auf die Organisation eines Unternehmens

    NASA Astrophysics Data System (ADS)

    Walter, Wolfram M.

    Die Digitalisierung schreitet mit großen Schritten voran. Dies wirkt sich nicht nur auf die Gesellschaft im Grundsatz, sondern auch auf das Verhalten der Kunden aus. Neue Kommunikationswege beschleunigen die Interaktion zwischen Unternehmen und Verbraucher. Im Vergleich mit großen Internetfirmen werden etablierte Dienstleistungsunternehmen - vom Energieversorger bis zu Versicherungen - stark unter Druck gesetzt, sich noch intensiver mit dem Kundenservice auseinanderzusetzen. Dies wird nur möglich sein, wenn sich die Organisationen entsprechend positionieren und sich frühzeitig auf die Veränderungen einstellen. Hieraus ergeben sich mehr Chancen als Risiken, zumal es nicht nur neue Prozesse, sondern auch neue Berufsbilder geben wird.

  1. Numerical simulation and experiment on multilayer stagger-split die.

    PubMed

    Liu, Zhiwei; Li, Mingzhe; Han, Qigang; Yang, Yunfei; Wang, Bolong; Sui, Zhou

    2013-05-01

    A novel ultra-high pressure device, multilayer stagger-split die, has been constructed based on the principle of "dividing dies before cracking." Multilayer stagger-split die includes an encircling ring and multilayer assemblages, and the mating surfaces of the multilayer assemblages are mutually staggered between adjacent layers. In this paper, we investigated the stressing features of this structure through finite element techniques, and the results were compared with those of the belt type die and single split die. The contrast experiments were also carried out to test the bearing pressure performance of multilayer stagger-split die. It is concluded that the stress distributions are reasonable and the materials are utilized effectively for multilayer stagger-split die. And experiments indicate that the multilayer stagger-split die can bear the greatest pressure.

  2. Euthanasia, assisted dying and the right to die in Ghana: a socio-legal analysis.

    PubMed

    Owusu-Dapaa, Ernest

    2013-12-01

    There is unanimity among states to protect the continuation of life of the individual as a safeguard against their collective extinction. The right to life is accordingly guaranteed but its antithesis, the right to die is the subject of an unending debate. The controversy over the right to die is deepened by rapid advances in medicine, creating the capability for prolongation of life beyond the span which one's natural strength can endure. Ghana's supreme law explicitly guarantees the right to life but remains ambiguous on right to die, particularly euthanasia and assisted dying. Thus, some of the other rights, such as the right to dignity and not to be tortured, can creatively be exploited to justify some instances of euthanasia. Ghana's criminal code largely proscribes euthanasia. Notwithstanding, proscription of euthanasia and assisted dying by the law, in Ghana's empirical work undertaken in some of the communities in Ghana, suggests that euthanasia is quietly practisedin health facilities and private homes, especially in the rural areas. Contrary to the popular reasons assigned in the literature of the Western world, with respect to the practice or quest for legalization of euthanasia as being a necessity for providing relief from pain or hopeless quality of life, empirical data from social and anthropological studies conducted in Ghana reveal that poverty is the motivation for informal euthanasia practice in Ghana rather than genuine desire on part of patients to die or their relatives to see to their accelerated death. Apart from poverty, traditional cultural values of African societies consider non-natural death as a taboo and ignominy to the victim and his family. Thus, any move by the government to legalize euthanasia will need to be informed by widely held consultations and a possible referendum; otherwise the law may be just a mere transplant of Western models of legislation on euthanasia without reflecting the ethos of the African people.

  3. New trends in radiology workstation design

    NASA Astrophysics Data System (ADS)

    Moise, Adrian; Atkins, M. Stella

    2002-05-01

    In the radiology workstation design, the race for adding more features is now morphing into an iterative user centric design with the focus on ergonomics and usability. The extent of the list of features for the radiology workstation used to be one of the most significant factors for a Picture Archiving and Communication System (PACS) vendor's ability to sell the radiology workstation. Not anymore is now very much the same between the major players in the PACS market. How these features work together distinguishes different radiology workstations. Integration (with the PACS/Radiology Information System (RIS) systems, with the 3D tool, Reporting Tool etc.), usability (user specific preferences, advanced display protocols, smart activation of tools etc.) and efficiency (what is the output a radiologist can generate with the workstation) are now core factors for selecting a workstation. This paper discusses these new trends in radiology workstation design. We demonstrate the importance of the interaction between the PACS vendor (software engineers) and the customer (radiologists) during the radiology workstation design. We focus on iterative aspects of the workstation development, such as the presentation of early prototypes to as many representative users as possible during the software development cycle and present the results of a survey of 8 radiologists on designing a radiology workstation.

  4. Immediate provisionalization in the esthetic zone: 1-year interim results from a prospective single-cohort multicenter study evaluating 3.0-mm-diameter tapered implants.

    PubMed

    Kolinski, Martin; Hess, Pablo; Leziy, Sonia; Friberg, Bertil; Bellucci, Gionata; Trisciuoglio, Davide; Wagner, Wilfried; Moergel, Maximilian; Pozzi, Alessandro; Wiltfang, Jörg; Behrens, Eleonore; Zechner, Werner; Vasak, Christoph; Weigl, Paul

    2018-07-01

    The aim of this interim analysis of a 5-year prospective multicenter study is to evaluate clinical and radiological performance of immediately provisionalized 3.0-mm-diameter tapered implants. Patients needing implant rehabilitation of maxillary lateral incisors or mandibular lateral and central incisors were treated with 3.0-mm-diameter implants placed in extraction or healed sites and immediately provisionalized. Clinical and radiographic examinations were performed at implant insertion, 6 months thereafter, and are ongoing. Marginal bone levels and changes, complications, the papilla, plaque, and bleeding indices, and the pink esthetic score (PES) were evaluated at each follow-up visit. Of 112 enrolled patients, 77 patients (91 implants) met the inclusion criteria. Seventy-one patients with 82 implants completed the 1-year follow-up. Three implants failed yielding a CSR of 96.7%. All failures occurred within the first 3 months after implant insertion. Marginal bone level changes from insertion to 6 months was - 0.57 ± 1.30 mm (n = 75) and from insertion to 12 months - 0.25 ± 1.38 mm (n = 72). Fifteen non-serious complications were recorded. Papilla index score and PES improved at the 1-year follow-up. Plaque formation and bleeding-on-probing showed no statistically significant differences between the 6-month and the 1-year visit. This 1-year analysis demonstrated high survival, stable bone levels, and healthy soft tissue with 3.0-mm-diameter implants. Narrow diameter implants are a safe and predictable treatment option in patients with limited bone volume and/or limited interdental space and eligible for immediate loading protocols.

  5. RF induced energy for partially implanted catheters: a computational study

    PubMed Central

    Lucano, Elena; Liberti, Micaela; Lloyd, Tom; Apollonio, Francesca; Wedan, Steve; Kainz, Wolfgang; Angelone, Leonardo M.

    2018-01-01

    Magnetic Resonance Imaging (MRI) is a radiological imaging technique widely used in clinical practice. MRI has been proposed to guide the catheters for interventional procedures, such as cardiac ablation. However, there are risks associated with this procedure, such as RF-induced heating of tissue near the catheters. The aim of this study is to develop a quantitative RF-safety method for patients with partially implanted leads at 64 MHz. RF-induced heating is related to the electric field incident along the catheter, which in turns depends on several variables, including the position of the RF feeding sources and the orientation of the polarization, which are however often unknown. This study evaluates the electric field profile along the lead trajectory using simulations with an anatomical human model landmarked at the heart. The energy absorbed in the volume near the tip of ageneric partially implanted lead was computed for all source positions and field orientation. The results showed that varying source positions and field orientation may result in changes of up to 18% for the E-field magnitude and up to 60% for the 10g-averaged specific absorption rate (SAR) in the volume surrounding the tip of the lead. PMID:28268553

  6. Sheet metal stamping die design for warm forming

    DOEpatents

    Ghosh, Amit K.

    2003-04-22

    In metal stamping dies, by taking advantage of improved material flow by selectively warming the die, flat sections of the die can contribute to the flow of material throughout the workpiece. Local surface heating can be accomplished by placing a heating block in the die. Distribution of heating at the flat lower train central regions outside of the bend region allows a softer flow at a lower stress to enable material flow into the thinner, higher strain areas at the bend/s. The heating block is inserted into the die and is powered by a power supply.

  7. Fast lichtschnell durch die Stadt: Visualisierung relativistischer Effekte

    NASA Astrophysics Data System (ADS)

    Kraus, Ute; Borchers, Marc P.

    2005-03-01

    Eine Computersimulation ermöglicht es uns, mit annähernd Lichtgeschwindigkeit durch die Tübinger Fußgängerzone zu fahren. Was wir dabei sehen, ist verblüffend: Die Häuser vor uns rücken umso weiter in die Ferne, je mehr wir beschleunigen; gleichzeitig erscheinen die Hauskanten in unserer Nähe immer stärker gekrümmt. Der Grund für diese merkwürdigen Bilder ist die so genannte Aberration: Ein und derselbe Lichtstrahl hat für den fahrenden Beobachter eine andere Richtung als für denjenigen, der am Straßenrand steht. Dieser Effekt ist im Alltag klein. Wenn wir aber in der Simulation fast lichtschnell durch die Tübinger Altstadt rasen, ist er dramatisch groß.

  8. Assisted Dying in Canada.

    PubMed

    Schuklenk, Udo

    This paper makes an affirmative ethical case in favour of the decriminalization of assisted dying in Canada. It then proceeds to defending the affirmative case against various slippery-slope arguments that are typically deployed by opponents of assisted dying. Finally, a recent case of questionable professional conduct by anti-euthanasia campaigners cum academics is flagged as a warning to all of us not to permit the quality of the professional debate to deteriorate unacceptably, despite the personal emotional investments involved on all sides of the debate.

  9. A clinical perspective on dying

    PubMed Central

    Janes, Robert G.

    1972-01-01

    There is continuing need for dissemination of already available, clinically useful knowledge concerning the psychological needs of the seriously ill and dying. Against the changing social context of dying, some of our erroneous assumptions about these patients are explored and the genuine fears and personal needs are discussed. The implications of this knowledge for medical education are recognized. PMID:5074753

  10. Occupational dose in interventional radiology procedures.

    PubMed

    Chida, Koichi; Kaga, Yuji; Haga, Yoshihiro; Kataoka, Nozomi; Kumasaka, Eriko; Meguro, Taiichiro; Zuguchi, Masayuki

    2013-01-01

    Interventional radiology tends to involve long procedures (i.e., long fluoroscopic times). Therefore, radiation protection for interventional radiology staff is an important issue. This study describes the occupational radiation dose for interventional radiology staff, especially nurses, to clarify the present annual dose level for interventional radiology nurses. We compared the annual occupational dose (effective dose and dose equivalent) among interventional radiology staff in a hospital where 6606 catheterization procedures are performed annually. The annual occupational doses of 18 physicians, seven nurses, and eight radiologic technologists were recorded using two monitoring badges, one worn over and one under their lead aprons. The annual mean ± SD effective dose (range) to the physicians, nurses, and radiologic technologists using two badges was 3.00 ± 1.50 (0.84-6.17), 1.34 ± 0.55 (0.70-2.20), and 0.60 ± 0.48 (0.02-1.43) mSv/y, respectively. Similarly, the annual mean ± SD dose equivalent range was 19.84 ± 12.45 (7.0-48.5), 4.73 ± 0.72 (3.9-6.2), and 1.30 ± 1.00 (0.2-2.7) mSv/y, respectively. The mean ± SD effective dose for the physicians was 1.02 ± 0.74 and 3.00 ± 1.50 mSv/y for the one- and two-badge methods, respectively (p < 0.001). Similarly, the mean ± SD effective dose for the nurses (p = 0.186) and radiologic technologists (p = 0.726) tended to be lower using the one-badge method. The annual occupational dose for interventional radiology staff was in the order physicians > nurses > radiologic technologists. The occupational dose determined using one badge under the apron was far lower than the dose obtained with two badges in both physicians and nonphysicians. To evaluate the occupational dose correctly, we recommend use of two monitoring badges to evaluate interventional radiology nurses as well as physicians.

  11. Marketing a Radiology Practice.

    PubMed

    Levin, David C; Rao, Vijay M; Flanders, Adam E; Sundaram, Baskaran; Colarossi, Margaret

    2016-10-01

    In addition to being a profession, the practice of radiology is a business, and marketing is an important part of that business. There are many facets to marketing a radiology practice. The authors present a number of ideas on how to go about doing this. Some marketing methods can be directed to both patients and referring physicians. Others should be directed just to patients, while still others should be directed just to referring physicians. Aside from marketing, many of them provide value to both target audiences. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  12. [Controlling instruments in radiology].

    PubMed

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  13. Radiology education: a glimpse into the future.

    PubMed

    Scarsbrook, A F; Graham, R N J; Perriss, R W

    2006-08-01

    The digital revolution in radiology continues to advance rapidly. There are a number of interesting developments within radiology informatics which may have a significant impact on education and training of radiologists in the near future. These include extended functionality of handheld computers, web-based skill and knowledge assessment, standardization of radiological procedural training using simulated or virtual patients, worldwide videoconferencing via high-quality health networks such as Internet2 and global collaboration of radiological educational resources via comprehensive, multi-national databases such as the medical imaging resource centre initiative of the Radiological Society of North America. This article will explore the role of e-learning in radiology, highlight a number of useful web-based applications in this area, and explain how the current and future technological advances might best be incorporated into radiological training.

  14. Historical review of die drool phenomenon during plastics extrusion

    NASA Astrophysics Data System (ADS)

    Musil, Jan; Zatloukal, Martin

    2013-04-01

    Die drool phenomenon is defined as unwanted spontaneous accumulation of extruded polymer melt on open faces of extrusion die during extrusion process. Such accumulated material builds up on the die exit and frequently or continually sticks onto the extruded product and thus damages it. Since die drool appears, extrusion process must be shut down and die exit must be manually cleaned which is time and money consuming. Although die drool is complex phenomenon and its formation mechanism is not fully understood yet, variety of proposed explanations of its formation mechanism and also many ways to its elimination can be found in open literature. Our review presents in historical order breakthrough works in the field of die drool research, shows many ways to suppress it, introduces methods for its quantitative evaluation and composition analysis and summarizes theories of die drool formation mechanism which can be helpful for extrusion experts.

  15. The Radiology Resident iPad Toolbox: an educational and clinical tool for radiology residents.

    PubMed

    Sharpe, Emerson E; Kendrick, Michael; Strickland, Colin; Dodd, Gerald D

    2013-07-01

    Tablet computing and mobile resources are the hot topics in technology today, with that interest spilling into the medical field. To improve resident education, a fully configured iPad, referred to as the "Radiology Resident iPad Toolbox," was created and implemented at the University of Colorado. The goal was to create a portable device with comprehensive educational, clinical, and communication tools that would contain all necessary resources for an entire 4-year radiology residency. The device was distributed to a total of 34 radiology residents (8 first-year residents, 8 second-year residents, 9 third-year residents, and 9 fourth-year residents). This article describes the process used to develop and deploy the device, provides a distillation of useful applications and resources decided upon after extensive evaluation, and assesses the impact this device had on resident education. The Radiology Resident iPad Toolbox is a cost-effective, portable, educational instrument that has increased studying efficiency; improved access to study materials such as books, radiology cases, lectures, and web-based resources; and increased interactivity in educational conferences and lectures through the use of audience-response software, with questions geared toward the new ABR board format. This preconfigured tablet fully embraces the technology shift into mobile computing and represents a paradigm shift in educational strategy. Copyright © 2013 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Implant Insertion Torque: Its Role in Achieving Primary Stability of Restorable Dental Implants.

    PubMed

    Greenstein, Gary; Cavallaro, John

    2017-02-01

    A literature review was conducted to determine the role of insertion torque in attaining primary stability of dental implants. The review is comprised of articles that discussed the amount of torque needed to achieve primary implant stability in healed ridges and fresh extraction sockets prior to immediate implant loading. Studies were appraised that addressed the effects of minimum and maximum forces that can be used to successfully place implants. The minimum torque that can be employed to attain primary stability is undefined. Forces ≥30 Ncm are routinely used to place implants into healed ridges and fresh extraction sockets prior to immediate loading of implants. Increased insertion torque (≥50 Ncm) reduces micromotion and does not appear to damage bone. In general, the healing process after implant insertion provides a degree of biologic stability that is similar whether implants are placed with high or low initial insertion torque. Primary stability is desirable when placing implants, but the absence of micromotion is what facilitates predictable implant osseointegration. Increased insertion torque helps achieve primary stability by reducing implant micromotion. Furthermore, tactile information provided by the first surgical twist drill can aid in selecting the initial insertion torque to achieve predictable stability of inserted dental implants.

  17. Immediate loading of tapered implants placed in postextraction sockets: retrospective analysis of the 5-year clinical outcome.

    PubMed

    Mura, Priamo

    2012-08-01

    The use of immediate implant loading protocols delivers obvious benefits to the patient. When applied in healed sites, this has not only been well documented in the totally edentolous mandible but has also been documented and reported to be predictable in the upper jaw, and in cases of partial edentoulism, as well. A further application of immediate loading protocol, although still controversial, especially when replacing single maxillary teeth in the anterior zone, is the immediate implant placement and provisionalization in postextractive sockets. In consideration of the oxidized surface promoting bone healing and the tapered shape of the implant body, the Replace Select Tapered TiUnite implants have been used for many years in our clinic when facing these clinical situations. This article will report about our long-term clinical experience with such implants and the relevant role of a correct surgical and prosthetic treatment planning. The aim of this retrospective study was to report on the 5-year clinical and radiologic outcome of patients treated with Replace Select Tapered TiUnite implants when used according to an immediate loading protocol in postextraction sites. In routine practice, 56 consecutive patients were treated with 79 implants. The patients, 23 males and 33 females, had a mean age of 50.9 years, range 21-76 years, at implant placement. Forty-seven implants were placed in the maxilla and 32 implants were placed in the mandible. All implants were placed in postextraction sites and were immediately loaded. Provisional restorations were delivered within 2 hours from surgery and all were in occlusion. Forty-three patients received a single implant while in the remaining 13 patients the implants were splinted. Definitive prosthetic restoration was delivered within 1 to 4 months following implant placement. Evaluations of soft tissue health and marginal bone remodeling were conducted. An independent radiologist performed the radiographic evaluation

  18. American Society of Radiologic Technologists

    MedlinePlus

    ... Radiologist Assistant Legislation Career Center Careers in Radiologic Technology Job Bank® Job Search Resources Radiologist ... American Society of Radiologic Technologists ASRT is the premier professional ...

  19. Is there more to the clinical outcome in posttraumatic reconstruction of the inferior and medial orbital walls than accuracy of implant placement and implant surface contouring? A prospective multicenter study to identify predictors of clinical outcome.

    PubMed

    Zimmerer, Rüdiger M; Gellrich, Nils-Claudius; von Bülow, Sophie; Strong, Edward Bradley; Ellis, Edward; Wagner, Maximilian E H; Sanchez Aniceto, Gregorio; Schramm, Alexander; Grant, Michael P; Thiam Chye, Lim; Rivero Calle, Alvaro; Wilde, Frank; Perez, Daniel; Bittermann, Gido; Mahoney, Nicholas R; Redondo Alamillos, Marta; Bašić, Joanna; Metzger, Marc; Rasse, Michael; Dittman, Jan; Rometsch, Elke; Espinoza, Kathrin; Hesse, Ronny; Cornelius, Carl-Peter

    2018-04-01

    Reconstruction of orbital wall fractures is demanding and has improved dramatically with the implementation of new technologies. True-to-original accuracy of reconstruction has been deemed essential for good clinical outcome, and reasons for unfavorable clinical outcome have been researched extensively. However, no detailed analysis on the influence of plate position and surface contour on clinical outcome has yet been published. Data from a previous study were used for an ad-hoc analysis to identify predictors for unfavorable outcome, defined as diplopia or differences in globe height and/or globe projection of >2 mm. Presumed predictors were implant surface contour, aberrant implant dimension or position, accuracy of reconstructed orbital volume, and anatomical fracture topography according to the current AO classification. Neither in univariable nor in multivariable regression models were unfavorable clinical outcomes associated with any of the presumed radiological predictors, and no association of the type of implant, i.e., standard preformed, CAD-based individualized and non-CAD-based individualized with its surface contour could be shown. These data suggest that the influence of accurate mechanical reconstruction on clinical outcomes may be less predictable than previously believed, while the role of soft-tissue-related factors may have been underestimated. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.

    PubMed

    Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich

    2008-11-06

    The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.

  1. ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology.

    PubMed

    Khong, P-L; Ringertz, H; Donoghue, V; Frush, D; Rehani, M; Appelgate, K; Sanchez, R

    2013-04-01

    Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities - radiography and fluoroscopy, interventional radiology, and computed tomography - are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation, use

  2. The Dying Role: Its Relevance to Improved Patient Care.

    PubMed

    Noyes, Russell; Clancy, John

    2016-01-01

    SOCIETY is failing to meet the obligation it has to its dying members. Persons with terminal illnesses suffer isolation and neglect in hospitals, receive overzealous treatment by physicians, and are kept in ignorance of their situation by families and medical personnel. Evidence for these statements has come from observers of the medical care system and from dying patients themselves (Kübler-Ross, 1969; Reynolds and Kalish, 1974; Sudnow, 1967). In the nineteenth century it was common for persons to die in the familiar environs of their homes, surrounded by grieving families from whom they parted in a meaningful manner (Blauner, 1966). Dying persons of today no longer fill a well-defined social role. Instead, the distinction between the roles of sick and dying persons has been lost and, in the resulting confusion, the care of dying people has suffered. The purpose of this article is to clarify the distinction between the dying and sick roles, identify the signs of existing role confusion, suggest ways in which this confusion may be corrected, and show how reestablishment of the dying role can result in improved care of dying people. The important part physicians play in defining sick and dying roles will be emphasized.

  3. [Intranet applications in radiology].

    PubMed

    Knopp, M V; von Hippel, G M; Koch, T; Knopp, M A

    2000-01-01

    The aim of the paper is to present the conceptual basis and capabilities of intranet applications in radiology. The intranet, which is the local brother of the internet can be readily realized using existing computer components and a network. All current computer operating systems support intranet applications which allow hard and software independent communication of text, images, video and sound with the use of browser software without dedicated programs on the individual personal computers. Radiological applications for text communication e.g. department specific bulletin boards and access to examination protocols; use of image communication for viewing and limited processing and documentation of radiological images can be achieved on decentralized PCs as well as speech communication for dictation, distribution of dictation and speech recognition. The intranet helps to optimize the organizational efficiency and cost effectiveness in the daily work of radiological departments in outpatients and hospital settings. The general interest in internet and intranet technology will guarantee its continuous development.

  4. Radiology Architecture Project Primer.

    PubMed

    Sze, Raymond W; Hogan, Laurie; Teshima, Satoshi; Davidson, Scott

    2017-12-19

    The rapid pace of technologic advancement and increasing expectations for patient- and family-friendly environments make it common for radiology leaders to be involved in imaging remodel and construction projects. Most radiologists and business directors lack formal training in architectural and construction processes but are expected to play significant and often leading roles in all phases of an imaging construction project. Avoidable mistakes can result in significant increased costs and scheduling delays; knowledgeable participation and communication can result in a final product that enhances staff workflow and morale and improves patient care and experience. This article presents practical guidelines for preparing for and leading a new imaging architectural and construction project. We share principles derived from the radiology and nonradiology literature and our own experience over the past decade completely remodeling a large pediatric radiology department and building a full-service outpatient imaging center. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  5. Short-term survival and effects of transmitter implantation into western grebes using a modified surgical procedure

    USGS Publications Warehouse

    Gaydos, Joseph K.; Massey, J. Gregory; Mulcahy, Daniel M.; Gaskins, Lori A.; Nysewander, David; Evenson, Joseph; Siegel, Paul B.; Ziccardi, Michael H.

    2011-01-01

    Two pilot trials and one study in a closely related grebe species suggest that Western grebes (Aechmophorus occidentalis) will not tolerate intracoelomic transmitter implantation with percutaneous antennae and often die within days of surgery. Wild Western grebes (n = 21) were captured to evaluate a modified surgical technique. Seven birds were surgically implanted with intracoelomic transmitters with percutaneous antennae by using the modified technique (transmitter group), 7 received the same surgery without transmitter implantation (celiotomy group), and 7 served as controls (only undergoing anesthesia). Modifications included laterally offsetting the body wall incision from the skin incision, application of absorbable cyanoacrylate tissue glue to the subcutaneous space between the body wall and skin incisions, application of a waterproof sealant to the skin incision after suture closure, and application of a piece of porcine small intestine submucosa to the antenna egress. Survival did not differ among the 3 groups with 7 of 7 control, 6 of 7 celiotomy, and 6 of 7 transmitter birds surviving the 9-day study. Experimental birds were euthanized at the end of the study, and postmortem findings indicated normal healing. Significant differences in plasma chemistry or immune function were not detected among the 3 groups, and only minor differences were detected in red blood cell indices and plasma proteins. After surgery, the birds in the transmitter group spent more time preening tail feathers than those in the control and celiotomy groups. These results demonstrate that, in a captive situation, celiotomy and intracoelomic transmitter implantation caused minimal detectable homeostatic disturbance in this species and that Western grebes can survive implantation of intracoelomic transmitters with percutaneous antennae. It remains to be determined what potential this modified surgical procedure has to improve postoperative survival of Western grebes that are

  6. Should radiology residents be taught evidence-based radiology? An experiment with "the EBR Journal Club".

    PubMed

    Heilbrun, Marta E

    2009-12-01

    Introduce radiology residents to evidence-based radiology (EBR) using a journal club format based on the Radiology Alliance for Health Services Research/American Alliance of Academic Chief Residents in Radiology (RAHSR/A3CR2) Critical Thinking Skills sessions and EBR series of articles published in Radiology in 2007. The club began with a presentation outlining the process that would occur in an alternating format, with topics and articles chosen by residents. In session A, questions were rephrased in a Patient/Population, Intervention, Comparison, Outcome format, and a literature search was performed. Articles were discussed in session B, with residents assigned by year to the tasks of article summary, technology assessment, and comparison to checklists (Standards for Reporting of Diagnostic Accuracy, Consolidated Standards of Reporting Trials, or Quality of Reporting of Meta-analysis). The residents collectively assigned a level of evidence to each article, and a scribe provided a summary. Twenty-two residents participated, with 12/22 (55%) of residents submitting any question, 6/22 (27.3%) submitting more than one question, and 4 residents submitting questions in more than one session. Topics included radiation risk, emergency radiology, screening examinations, modality comparisons, and technology assessment. Of the 31 articles submitted for review, 15 were in radiology journals and 5 were published before 2000. For 2/9 topics searched, no single article that the residents selected was available through our library's subscription service. The maximum level of evidence assigned by residents was level III, "limited evidence." In each session, the residents concluded that they became less confident in the "right answer." They proposed that future reading recommendations come from attendings rather than literature searches. A journal club format is an effective tool to teach radiology residents EBR principles. Resistance comes from the difficulty in accessing good

  7. 'Bridging worlds': meeting the emotional needs of dying patients.

    PubMed

    Law, Rollanda

    2009-12-01

    This paper is a report of a study to develop a grounded theory to explain how district nurses meet the emotional needs of dying patients in the community. There has been a policy commitment internationally to improve community services and enable people with terminal illnesses to die in their own homes. This increasing trend towards home deaths in the United Kingdom (UK) makes more demand on district nurses to provide emotional support for dying patients. A 'classic' grounded theory study was conducted in the UK between 2002 and 2005. Unstructured observations and semi-structured interviews were conducted with a purposive sample of nine district nurses, nine patients and four family carers. A further theoretical sample of five books of authors' accounts of their dying experiences and three district nurses who were advanced practitioners were selected. Five categories were identified in the data: 'outside world', 'dying world', 'entering dying world', 'maintaining connections' and the core category 'bridging worlds'. The theory of 'bridging worlds' indicated that dying patients experienced 'dying world' and 'outside world'. District nurses met dying patients' emotional needs by acting as a bridge between their two worlds, encouraging them to maintain connections with the outside world so that they did not become isolated in their dying world. District nurses should ensure that they meet both the physical and emotional needs of dying patients. Nursing education and literature need to concentrate on raising awareness of nurses' role in providing emotional support.

  8. De-tabooing dying control - a grounded theory study

    PubMed Central

    2013-01-01

    Background Dying is inescapable yet remains a neglected issue in modern health care. The research question in this study was “what is going on in the field of dying today?” What emerged was to eventually present a grounded theory of control of dying focusing specifically on how people react in relation to issues about euthanasia and physician-assisted suicide (PAS). Methods Classic grounded theory was used to analyze interviews with 55 laypersons and health care professionals in North America and Europe, surveys on attitudes to PAS among physicians and the Swedish general public, and scientific literature, North American discussion forum websites, and news sites. Results Open awareness of the nature and timing of a patient’s death became common in health care during the 1960s in the Western world. Open dying awareness contexts can be seen as the start of a weakening of a taboo towards controlled dying called de-tabooing. The growth of the hospice movement and palliative care, but also the legalization of euthanasia and PAS in the Benelux countries, and PAS in Montana, Oregon and Washington further represents de-tabooing dying control. An attitude positioning between the taboo of dying control and a growing taboo against questioning patient autonomy and self-determination called de-paternalizing is another aspect of de-tabooing. When confronted with a taboo, people first react emotionally based on “gut feelings” - emotional positioning. This is followed by reasoning and label wrestling using euphemisms and dysphemisms - reflective positioning. Rarely is de-tabooing unconditional but enabled by stipulated positioning as in soft laws (palliative care guidelines) and hard laws (euthanasia/PAS legislation). From a global perspective three shapes of dying control emerge. First, suboptimal palliative care in closed awareness contexts seen in Asian, Islamic and Latin cultures, called closed dying. Second, palliative care and sedation therapy, but not euthanasia

  9. Upper full arch rehabilitation with sinus by-pass with tilted implants via tapered-threaded expanders in low density bone: a clinical trial.

    PubMed

    Andreasi Bassi, M; Andrisani, C; Lico, S; Ormanier, Z; Arcuri, C

    2016-01-01

    In the present paper the use of tapered-screw bone expanders (TSBEs) is proposed, in combination with the placement of tilted implants, in close proximity to the anterior sinus wall, solving the problem of the reduced height of the alveolar bone in the sub-antral area. The Authors present a case series of full-arch rehabilitations performed with this procedure named: Tilted Implant Expansion Osteotomy (TIEO). 12 patients (5 males and 7 females, average age 58.5 ± 8.1 years) with totally or partially edentulous maxilla were enrolled in this study. For each patient 4 implants were placed, the anterior implants in the area of lateral incisors or canines while, the posterior implants, immediately in front of the maxillary sinus, with an inclined position. Adopting the aforesaid procedure, 48 cylindrical two-piece implants were placed, 24 of which were placed in tilted position, in order to by-pass the maxillary sinus. After a healing period of 6 months, the second stage surgery was performed. The cases were finalized by means of a hybrid metal-acrylic prosthesis. The post finalization follow-up was at 12 months. Survival rate was 100% since none fixtures were lost. At the one-year follow up the clinical and radiological appearance of the soft and hard tissues was optimal and no pathological signs were recorded. TIEO is a promising surgical procedure for full-arch rehabilitation of maxillary edentulous sites and represents a therapeutic alternative to sinus lift techniques.

  10. Influence of controlled immediate loading and implant design on peri-implant bone formation.

    PubMed

    Vandamme, Katleen; Naert, Ignace; Geris, Liesbet; Vander Sloten, Jozef; Puers, Robert; Duyck, Joke

    2007-02-01

    Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. A significantly higher bone area fraction was observed for SL compared with SU (p<0.0001). The mineralized bone fraction was the highest for SL and significantly different from SU (p<0.0001). The chance that osteoid- and bone-to-implant contact occurred was the highest for SL and significantly different from SU (p<0.0001), but not from CL. When bone-to-implant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.

  11. Acting to let someone die.

    PubMed

    McGee, Andrew

    2015-02-01

    This paper examines the recent prominent view in medical ethics that withdrawing life-sustaining treatment (LST) is an act of killing. I trace this view to the rejection of the traditional claim that withdrawing LST is an omission rather than an act. Although that traditional claim is not as problematic as this recent prominent view suggests, my main claim is that even if we accepted that withdrawing LST should be classified as an act rather than as an omission, it could still be classified as letting die rather than killing. Even though omissions are contrasted with acts, letting die need not be, for one can let die by means of acts. The remainder of the paper is devoted to establishing this claim and addresses certain objections to it. © 2013 John Wiley & Sons Ltd.

  12. CNC-milled titanium frameworks supported by implants in the edentulous jaw: a 10-year comparative clinical study.

    PubMed

    Örtorp, Anders; Jemt, Torsten

    2012-03-01

    No long-term clinical studies covering more than 5 years are available on Computer Numeric Controlled (CNC) milled titanium frameworks. To evaluate and compare the clinical and radiographic performance of implant-supported prostheses provided with CNC titanium frameworks in the edentulous jaw with prostheses with cast gold-alloy frameworks during the first 10 years of function. Altogether, 126 edentulous patients were by random provided with 67 prostheses with titanium frameworks (test) in 23 maxillas and 44 mandibles, and with 62 prostheses with gold-alloy castings (control) in 31 maxillas and 31 mandibles. Clinical and radiographic 10-year data were collected for the groups and statistically compared on patient level. The 10-year prosthesis and implant cumulative survival rate was 95.6% compared with 98.3%, and 95.0% compared with 97.9% for test and control groups, respectively (p > .05). No implants were lost after 5 years of follow-up. Smokers lost more implants than nonsmokers after 5 years of follow-up (p < .01). Mean marginal bone loss in the test group was 0.7 mm (SD 0.61) and 0.7 mm (SD 0.85) in the maxilla and mandible, with similar pattern in the control group (p > .05), respectively. One prosthesis was lost in each group due to loss of implants, and one prosthesis failed due to framework fracture in the test group. Two metal fractures were registered in each group. More appointments of maintenance were needed for the prostheses in the maxilla compared with those in the mandible (p < .001). The frequency of complications was low with similar clinical and radiological performance for both groups during 10 years. CNC-milled titanium frameworks are a viable alternative to gold-alloy castings for restoring patients with implant-supported prostheses in the edentulous jaw. © 2009 Wiley Periodicals, Inc.

  13. Computer aided system for parametric design of combination die

    NASA Astrophysics Data System (ADS)

    Naranje, Vishal G.; Hussein, H. M. A.; Kumar, S.

    2017-09-01

    In this paper, a computer aided system for parametric design of combination dies is presented. The system is developed using knowledge based system technique of artificial intelligence. The system is capable to design combination dies for production of sheet metal parts having punching and cupping operations. The system is coded in Visual Basic and interfaced with AutoCAD software. The low cost of the proposed system will help die designers of small and medium scale sheet metal industries for design of combination dies for similar type of products. The proposed system is capable to reduce design time and efforts of die designers for design of combination dies.

  14. Influence of Implant Positions and Occlusal Forces on Peri-Implant Bone Stress in Mandibular Two-Implant Overdentures: A 3-Dimensional Finite Element Analysis.

    PubMed

    Alvarez-Arenal, Angel; Gonzalez-Gonzalez, Ignacio; deLlanos-Lanchares, Hector; Brizuela-Velasco, Aritza; Dds, Elena Martin-Fernandez; Ellacuria-Echebarria, Joseba

    2017-12-01

    The aim of this study was to evaluate and compare the bone stress around implants in mandibular 2-implant overdentures depending on the implant location and different loading conditions. Four 3-dimensional finite element models simulating a mandibular 2-implant overdenture and a Locator attachment system were designed. The implants were located at the lateral incisor, canine, second premolar, and crossed-implant levels. A 150 N unilateral and bilateral vertical load of different location was applied, as was 40 N when combined with midline load. Data for von Mises stress were produced numerically, color coded, and compared between the models for peri-implant bone and loading conditions. With unilateral loading, in all 4 models much higher peri-implant bone stress values were recorded on the load side compared with the no-load side, while with bilateral occlusal loading, the stress distribution was similar on both sides. In all models, the posterior unilateral load showed the highest stress, which decreased as the load was applied more mesially. In general, the best biomechanical environment in the peri-implant bone was found in the model with implants at premolar level. In the crossed-implant model, the load side greatly altered the biomechanical environment. Overall, the overdenture with implants at second premolar level should be the chosen design, regardless of where the load is applied. The occlusal loading application site influences the bone stress around the implant. Bilateral occlusal loading distributes the peri-implant bone stress symmetrically, while unilateral loading increases it greatly on the load side, no matter where the implants are located.

  15. Echocardiographic variables after left ventricular assist device implantation associated with adverse outcome.

    PubMed

    Topilsky, Yan; Hasin, Tal; Oh, Jae K; Borgeson, Daniel D; Boilson, Barry A; Schirger, John A; Clavell, Alfredo L; Frantz, Robert P; Tsutsui, Rayji; Liu, Mingya; Maltais, Simon; Kushwaha, Sudhir S; Pereira, Naveen L; Park, Soon J

    2011-11-01

    Operative mortality after left ventricular assist device (LVAD) implantation is heavily influenced by patient selection and the technical difficulty of surgery. However, how we treat our patients and LVAD setting may affect the patient outcome beyond this period. We postulated that the presence of echocardiographic variables 1 month after surgery suggesting appropriate degree of LV unloading and an adequate forward flow would be important in determining clinical outcomes after the initial successful LVAD implantation. We retrospectively analyzed various variables in echocardiographic examinations performed 30 days after LVAD implant in 76 consecutive patients receiving continuous flow device for their association with a compound end point (90-day mortality, readmission for heart failure, or New York Heart Association class III or higher at the end of the 90-day period). The echocardiographic associations examined included estimated LVAD flow, with and without native LV contribution, interventricular septal position, the status of aortic valve opening, an estimated left atrial pressure (ELAP), the mitral flow E-wave deceleration time, and the ratio of deceleration time to E-wave velocity (mitral deceleration index [MDI]). Four patients died during the 30- to 90-day period, 6 patients were readmitted for heart failure, and 25 patients were considered to have New York Heart Association class III or higher at the end of the 90-day period. Variables associated with adverse outcome included increased ELAP (odds ratio, 1.30 [1.16-1.48]; P<0.0001), MDI <2 ms/[cm/s] (odds ratio, 4.4 implantation [1.22-18]; P=0.02) and decreased tricuspid lateral annulus velocity (odds ratio, 0.70 implantation [0.48-0.95]; P=0.02). A leftward deviation of interventricular septum was associated with a worse outcome (odds ratio, 3.03 implantation [1.21-13.3]; P=0.01). Mortality and heart failure after LVAD surgery appear to be predominantly determined by echocardiographic evidence of

  16. Progestin implants can rescue demi-embryo pregnancies in goats: a case study.

    PubMed

    Beckett, D M; Oppenheim, S M; Moyer, A L; BonDurant, R H; Rowe, J D; Anderson, G B

    1999-06-01

    Survival after transfer of demi-embryos (i.e., half-embryos produced by embryo splitting) to recipients usually is lower than survival after transfer of intact embryos. Reduced survival after demi-embryo transfer could be due to loss of viability after splitting, failure of a viable demi-embryo to prevent corpus luteum (CL) regression in the recipient female, or a combination of factors. From a retrospective analysis of pregnancy and embryo survival rates after demi-embryo transfer in sheep and goats, we report the rescue of caprine demi-embryo pregnancies in which CL regression occurred at the end of diestrus despite the presence of a viable conceptus in the uterus with progestin implants. Day 5 or 6 morulae and blastocysts were flushed from superovulated ewes and does and split into demi-embryos of approximately equal halves. Demi-embryos were either transferred fresh to synchronized recipients of the homologous species or frozen in liquid nitrogen. Approximately half of the recipient does and ewes were treated with norgestomet implants on Day 10 of the embryo transfer cycle and again 2 wk later. Serum collected on Day 25 from recipients with implants was assayed for progesterone to determine if a CL of pregnancy had been maintained. Pregnancy was diagnosed by ultrasonography on Day 35 of gestation. Corpus luteum regression occurred despite the presence of a viable conceptus in the uterus in 6 of 55 progestin-treated caprine demi-embryo recipients and in 0 of 66 ovine demi-embryo recipients. Five of the caprine pregnancies were maintained to term with norgestomet implants and produced 5 live kids. The sixth fetus, which was carried by a progestin implant-treated 8-mo-old doeling, died at approximately 50 d of gestation. These results suggest that, at least in goats, some demi-embryos may provide inadequate signaling for maternal recognition of pregnancy, and such pregnancies can be rescued with progestin treatment to the doe.

  17. Peri-implant bone formation and implant integration strength of peptide-modified p(AAM-co-EG/AAC) interpenetrating polymer network-coated titanium implants.

    PubMed

    Barber, Thomas A; Ho, James E; De Ranieri, Aladino; Virdi, Amarjit S; Sumner, Dale R; Healy, Kevin E

    2007-02-01

    Interpenetrating polymer networks (IPNs) of poly (acrylamide-co-ethylene glycol/acrylic acid) functionalized with an -Arg-Gly-Asp- (RGD) containing 15 amino acid peptides, derived from rat bone sialoprotein (bsp-RGD(15), were grafted to titanium implants in an effort to modulate bone formation in the peri-implant region in the rat femoral ablation model. Bone-implant contact (BIC) and bone formation within the medullary canal were determined using microcomputed tomography at 2 and 4 weeks postimplantation. BIC for bsp-RGD(15)-IPN implants was enhanced relative to hydroxyapatite tricalcium phosphate (HA-TCP) coated implants, but was similar to all other groups. Aggregate bone formation neither indicated a dose-dependent effect of bsp-RGD(15) nor a meaningful trend. Mechanical testing of implant fixation revealed that only the HA-TCP coated implants supported significant (>1 MPa) interfacial shear strength, despite exhibiting lower overall BIC, an indication that bone ingrowth into the rougher coating was the primary mode of implant fixation. While no evidence was found to support the hypothesis that bsp-RGD(15)-modified IPN coated implants significantly impacted bone-implant bonding, these results point to the lack of correlation between in vitro studies employing primary osteoblasts and in vivo wound healing in the peri-implant region. Copyright 2006 Wiley Periodicals, Inc.

  18. REFRACTORY DIE FOR EXTRUDING URANIUM

    DOEpatents

    Creutz, E.C.

    1959-08-11

    A die is presented for the extrusion of metals, said die being formed of a refractory complex oxide having the composition M/sub n/O/sub m/R/sub x/O/sub y/ where M is magnesium, zinc, manganese, or iron, R is aluminum, chromic chromium, ferric iron, or manganic manganese, and m, n, x, and y are whole numbers. Specific examples are spinel, magnesium aluminate, magnetite, magnesioferrite, chromite, and franklinite.

  19. A 10-year clinical and radiographic study of implants placed after maxillary sinus floor augmentation with an 80:20 mixture of deproteinized bovine bone and autogenous bone.

    PubMed

    Mordenfeld, Arne; Albrektsson, Tomas; Hallman, Mats

    2014-06-01

    There is a need for prospective, long-term follow-up studies of implants placed after maxillary sinus floor augmentation (MSFA). The aim of the present study was to determine whether deprotenized bovine bone (DPBB) used for MSFA may result in long-term stability of placed dental implants. Fourteen of the 20 patients included in the study were followed throughout the 10 years study period. These patients had 53 implants placed in 22 (6 unilateral and 8 bilateral) maxillary sinuses augmented with a mixture of 80% DPBB and 20% autogenous bone (80:20), and 15 implants placed in non-grafted sites. Clinical and radiographic examinations of the implants and grafts were performed. After 10 years of functional loading 15 of the initially placed 108 implants had been lost giving a cumulative survival rate of 86%. The mean marginal bone loss was 1.6 ± 1.0 mm. There were no statistically significant differences in marginal bone level, pocket depth, or ISQ-values between implants placed in residual or grafted bone or between smokers or non-smokers at 10 years follow-up. There was a statistically significant reduction (p < .01) in graft height between 3 months and 2 years but no further significant reduction up to 10 years. The first 2 years after placement of implants with turned surfaces placed in sites after sinus floor augmentation with DPBB and autogenous bone seem to be critical for implant survival. At 10 years follow-up, the remaining implants presented excellent clinical and radiological results regardless of smoking habits or implant sites (augmented or residual bone). © 2012 Wiley Periodicals, Inc.

  20. Trends in radiology and experimental research.

    PubMed

    Sardanelli, Francesco

    2017-01-01

    European Radiology Experimental , the new journal launched by the European Society of Radiology, is placed in the context of three general and seven radiology-specific trends. After describing the impact of population aging, personalized/precision medicine, and information technology development, the article considers the following trends: the tension between subspecialties and the unity of the discipline; attention to patient safety; the challenge of reproducibility for quantitative imaging; standardized and structured reporting; search for higher levels of evidence in radiology (from diagnostic performance to patient outcome); the increasing relevance of interventional radiology; and continuous technological evolution. The new journal will publish not only studies on phantoms, cells, or animal models but also those describing development steps of imaging biomarkers or those exploring secondary end-points of large clinical trials. Moreover, consideration will be given to studies regarding: computer modelling and computer aided detection and diagnosis; contrast materials, tracers, and theranostics; advanced image analysis; optical, molecular, hybrid and fusion imaging; radiomics and radiogenomics; three-dimensional printing, information technology, image reconstruction and post-processing, big data analysis, teleradiology, clinical decision support systems; radiobiology; radioprotection; and physics in radiology. The journal aims to establish a forum for basic science, computer and information technology, radiology, and other medical subspecialties.

  1. Twenty-Seven Years Experience With Transvenous Pacemaker Implantation in Children Weighing <10 kg.

    PubMed

    Konta, Laura; Chubb, Mark Henry; Bostock, Julian; Rogers, Jan; Rosenthal, Eric

    2016-02-01

    Epicardial pacemaker implantation is the favored approach in children weighing <10 kg in many units. The high incidence of premature failure and fractures with earlier epicardial leads led our unit to undertake transvenous pacemaker implantation in neonates and infants from 1987. To date there have been no long-term follow-up reports of what is for many a controversial strategy. Between 1987 and 2003, 37 neonates and infants-median age 6.7 months (1 day to 3 years) and median weight 4.6 kg (2.7-10 kg)-had a permanent transvenous pacing system implanted. Pacing leads were placed into the right ventricular apex/outflow tract through a subclavian vein puncture with a redundant loop in the atrium. Three patients were lost to follow-up, 4 patients died from complications of cardiac surgery, and 2 patients had their system removed. At long-term follow-up in 28 patients at a median of 17.2 (range, 11.2-27.4) years, 10 patients have a single chamber ventricular pacemaker, 14 a dual chamber pacemaker, 3 a biventricular pacemaker, and 1 has a single chamber implantable cardioverter defibrillator. Subclavian vein patency was assessed in 26 patients. The overall subclavian vein occlusion rate was 10 of 13 (77%) <5 kg and 2 of 13 (15%) >5 kg during long-term follow-up. After a median of 14.3 (range, 13.4-17.6) years of pacing, 7 patients continue with their original lead. Transvenous pacing in infants <10 kg results in encouraging short- and long-term clinical outcomes. Subclavian vein occlusion remains an important complication, occurring predominantly in those weighing <5 kg. © 2016 American Heart Association, Inc.

  2. A Contingency Framework for Listening to the Dying

    ERIC Educational Resources Information Center

    Vora, Erika; Vora, Ariana

    2008-01-01

    Listening to the dying poses special challenges. This paper proposes a contingency framework for describing and assessing various circumstances when listening to the dying. It identifies current approaches to listening, applies the contingency framework toward effectively listening to the dying, and proposes a new type of listening called…

  3. Assessing Timing and Causes of Neonatal Lamb Losses in a Bighorn Sheep ( Ovis canadensis canadensis ) Herd via Use of Vaginal Implant Transmitters.

    PubMed

    Grigg, Jamin L; Wolfe, Lisa L; Fox, Karen A; Killion, Halcyon J; Jennings-Gaines, Jessica; Miller, Michael W; P Dreher, Brian

    2017-07-01

    We evaluated the use of vaginal implant transmitters (VITs) as a means of detecting, capturing, and radio collaring Rocky Mountain bighorn sheep ( Ovis canadensis canadensis) lambs to estimate survival and to facilitate carcass recovery to assess causes of mortality. We focused on one of several bighorn herds in Colorado, US, suffering from depressed recruitment that was not preceded by a classic all-age die-off. We captured, radio-collared, diagnosed pregnancy by ultrasound examination, and inserted VITs into 15 pregnant ewes from a herd residing near Granite, Colorado. We were subsequently able to collar a lamb from each of 13 VITs, and two additional lambs opportunistically from ewes without transmitters. As lambs died, we recovered and submitted carcasses for necropsy and laboratory assessment. All lambs captured and one additional lamb (carcass found opportunistically) were dead by about 130 d of age: 11 died of apparent pneumonia (all within 8-10 wk of age), one died from trauma after being kicked or trampled, one was killed by a mountain lion ( Puma concolor ), and three died of starvation likely caused by abandonment after capture. Pneumonic lambs had involvement of Mycoplasma ovipneumoniae and leukotoxigenic Bibersteinia trehalosi . The use of VITs and lamb collars enabled us to efficiently identify pneumonia as the predominant cause of depressed lamb recruitment in this herd; however, we urge care in neonatal lamb handling to minimize abandonment.

  4. A new system of implant abutment connection: how to improve a two piece implant system sealing.

    PubMed

    Grecchi, F; DI Girolamo, M; Cura, F; Candotto, V; Carinci, F

    2017-01-01

    Implant dentistry has become one of the most successful dentistry techniques for replacing missing teeth. The success rate of implant dentistry is above 80%. However, peri-implantitis is a later complication of implant dentistry that if untreated, can lead to implant loss. One of the hypotized causes of peri-implantis is the bacterial leakage at the level of implant-abutment connection. Bacterial leakage is favored to the presence of a micro gap at the implant-abutment interface, allowing microorganisms to penetrate and colonize the inner part of the implant leading to biofilm accumulation and consequently to peri-implantitis development. To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 9%. The reported results are better to those of previous studies carried out on different implant systems. Until now, none implant-abutment system has been proven to seal the gap between implant and abutment.

  5. The American Board of Radiology Maintenance of Certification (MOC) Program in Radiologic Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, Stephen R.; Hendee, William R.; Paliwal, Bhudatt R.

    2005-01-01

    Maintenance of Certification (MOC) recognizes that in addition to medical knowledge, several essential elements involved in delivering quality care must be developed and maintained throughout one's career. The MOC process is designed to facilitate and document the professional development of each diplomate of The American Board of Radiology (ABR) through its focus on the essential elements of quality care in Diagnostic Radiology and its subspecialties, and in the specialties of Radiation Oncology and Radiologic Physics. The initial elements of the ABR-MOC have been developed in accord with guidelines of The American Board of Medical Specialties. All diplomates with a ten-year,more » time-limited primary certificate in Diagnostic Radiologic Physics, Therapeutic Radiologic Physics, or Medical Nuclear Physics who wish to maintain certification must successfully complete the requirements of the appropriate ABR-MOC program for their specialty. Holders of multiple certificates must meet ABR-MOC requirements specific to the certificates held. Diplomates with lifelong certificates are not required to participate in the MOC, but are strongly encouraged to do so. MOC is based on documentation of individual participation in the four components of MOC: (1) professional standing, (2) lifelong learning and self-assessment, (3) cognitive expertise, and (4) performance in practice. Within these components, MOC addresses six competencies: medical knowledge, patient care, interpersonal and communication skills, professionalism, practice-based learning and improvement, and systems-based practice.« less

  6. 324 Building Baseline Radiological Characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R.J. Reeder, J.C. Cooper

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building.

  7. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.

    PubMed

    Klein, Doron; Hadad, Eran; Wiser, Itay; Wolf, Omer; Itzhaki Shapira, Ortal; Fucks, Shir; Heller, Lior

    2018-01-01

    Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.

  8. PathBot: A Radiology-Pathology Correlation Dashboard.

    PubMed

    Kelahan, Linda C; Kalaria, Amit D; Filice, Ross W

    2017-12-01

    Pathology is considered the "gold standard" of diagnostic medicine. The importance of radiology-pathology correlation is seen in interdepartmental patient conferences such as "tumor boards" and by the tradition of radiology resident immersion in a radiologic-pathology course at the American Institute of Radiologic Pathology. In practice, consistent pathology follow-up can be difficult due to time constraints and cumbersome electronic medical records. We present a radiology-pathology correlation dashboard that presents radiologists with pathology reports matched to their dictations, for both diagnostic imaging and image-guided procedures. In creating our dashboard, we utilized the RadLex ontology and National Center for Biomedical Ontology (NCBO) Annotator to identify anatomic concepts in pathology reports that could subsequently be mapped to relevant radiology reports, providing an automated method to match related radiology and pathology reports. Radiology-pathology matches are presented to the radiologist on a web-based dashboard. We found that our algorithm was highly specific in detecting matches. Our sensitivity was slightly lower than expected and could be attributed to missing anatomy concepts in the RadLex ontology, as well as limitations in our parent term hierarchical mapping and synonym recognition algorithms. By automating radiology-pathology correlation and presenting matches in a user-friendly dashboard format, we hope to encourage pathology follow-up in clinical radiology practice for purposes of self-education and to augment peer review. We also hope to provide a tool to facilitate the production of quality teaching files, lectures, and publications. Diagnostic images have a richer educational value when they are backed up by the gold standard of pathology.

  9. Sacroiliac joint stability: Finite element analysis of implant number, orientation, and superior implant length.

    PubMed

    Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K

    2018-03-18

    To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System ® ). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results.

  10. Die nuklearen Anlagen von Hanford (1943-1987) Eine Fallstudie über die Schnittstellen von Physik, Biologie und die US-amerikanische Gesellschaft zur Zeit des Kalten Krieges

    NASA Astrophysics Data System (ADS)

    Macuglia, Daniele

    Die Geschichte des Kalten Krieges eröffnet viele Möglichkeiten, sich näher mit den Schnittstellen von Physik und Biologie während des 20. Jahrhunderts zu befassen. Nicht nur das Unglück in Tschernobyl aus dem Jahr 1986, auch das Beispiel der nuklearen Anlagen in Hanford in den Vereinigten Staaten zeigt die biologischen Folgen von nuklearer Physik.

  11. Radiologic Professionalism in Modern Health Care.

    PubMed

    Hryhorczuk, Anastasia L; Hanneman, Kate; Eisenberg, Ronald L; Meyer, Elaine C; Brown, Stephen D

    2015-10-01

    Modern radiology is at the forefront of technological progress in medicine, a position that often places unique challenges on its professional character. This article uses "Medical Professionalism in the New Millennium: A Physician Charter," a document published in 2002 and endorsed by several major radiology organizations, as a lens for exploring professional challenges in modern radiology. The three main tenets of the Charter emphasize patient welfare, patient autonomy, and the reduction of disparities in health care distribution. This article reviews the ways in which modern technology and financial structures potentially create stressors on professionalism in radiology, while highlighting the opportunities they provide for radiologists seeking to fulfill the professional goals articulated in the Charter. Picture archiving and communication systems (PACS) and voice recognition systems have transformed the speed of radiology and enhanced the ability of radiologists to improve patient care but also have brought new tensions to the workplace. Although teleradiology may improve global access to radiologists, it may also promote the commoditization of radiology, which diminishes the professional stature of radiologists. Social media and patient portals provide radiologists with new forums for interacting with the public and patients, potentially promoting patient welfare. However, patient privacy and autonomy are important considerations. Finally, modern financial structures provide radiologists with both entrepreneurial opportunities as well as the temptation for unprofessional conduct. Each of these advances carries the potential for professional growth while testing the professional stature of radiology. By considering the risks and benefits of emerging technologies in the modern radiology world, radiologists can chart an ethical and professional future path. © RSNA, 2015.

  12. The pros and cons of intraoperative CT scan in evaluation of deep brain stimulation lead implantation: A retrospective study

    PubMed Central

    Servello, Domenico; Zekaj, Edvin; Saleh, Christian; Pacchetti, Claudio; Porta, Mauro

    2016-01-01

    Background: Deep brain stimulation (DBS) is an established therapy for movement disorders, such as Parkinson's disease (PD), dystonia, and tremor. The efficacy of DBS depends on the correct lead positioning. The commonly adopted postoperative radiological evaluation is performed with computed tomography (CT) scan and/or magnetic resonance imaging (MRI). Methods: We conducted a retrospective study on 202 patients who underwent DBS from January 2009 to October 2013. DBS indications were PD, progressive supranuclear palsy, tremor, dystonia, Tourette syndrome, obsessive compulsive disorder, depression, and Huntington's disease. Preoperatively, all patients underwent brain MRI and brain CT scan with the stereotactic frame positioned. The lead location was confirmed intraoperatively with CT. The CT images were subsequently transferred to the Stealth Station Medtronic and merged with the preoperative planning. On the first or second day after, implantation we performed a brain MRI to confirm the correct position of the lead. Results: In 14 patients, leads were in suboptimal position after intraoperative CT scan positioning. The cases with alteration in the Z-axis were corrected immediately under fluoroscopic guidance. In all the 14 patients, an immediate repositioning was done. Conclusions: Based on our data, intraoperative CT scan is fast, safe, and a useful tool in the evaluation of the position of the implanted lead. It also reduces the patient's discomfort derived from the transfer of the patient from the operating room to the radiological department. However, intraoperative CT should not be considered as a substitute for postoperative MRI. PMID:27583182

  13. Vitamin E Phosphate Coating Stimulates Bone Deposition in Implant-related Infections in a Rat Model.

    PubMed

    Lovati, Arianna B; Bottagisio, Marta; Maraldi, Susanna; Violatto, Martina B; Bortolin, Monica; De Vecchi, Elena; Bigini, Paolo; Drago, Lorenzo; Romanò, Carlo L

    2018-06-01

    Implant-related infections are associated with impaired bone healing and osseointegration. In vitro antiadhesive and antibacterial properties and in vivo antiinflammatory effects protecting against bone loss of various formulations of vitamin E have been demonstrated in animal models. However, to the best of our knowledge, no in vivo studies have demonstrated the synergistic activity of vitamin E in preventing bacterial adhesion to orthopaedic implants, thus supporting the bone-implant integration. The purpose of this study was to test whether a vitamin E phosphate coating on titanium implants may be able to reduce (1) the bacterial colonization of prosthetic implants and (2) bone resorption and osteomyelitis in a rat model of Staphylococcus aureus-induced implant-related infection. Twelve rats were bilaterally injected in the femurs with S aureus UAMS-1-Xen40 and implanted with uncoated or vitamin E phosphate-coated titanium Kirschner wires without local or systemic antibiotic prophylaxis. Eight rats represented the uninfected control group. A few hours after surgery, two control and three infected animals died as a result of unexpected complications. With the remaining rats, we assessed the presence of bacterial contamination with qualitative bioluminescence imaging and Gram-positive staining and with quantitative bacterial count. Bone changes in terms of resorption and osteomyelitis were quantitatively analyzed through micro-CT (bone mineral density) and semiquantitatively through histologic scoring systems. Six weeks after implantation, we found only a mild decrease in bacterial count in coated versus uncoated implants (Ti versus controls: mean difference [MD], -3.705; 95% confidence interval [CI], -4.416 to -2.994; p < 0.001; TiVE versus controls: MD, -3.063; 95% CI, -3.672 to -2.454; p < 0.001), whereas micro-CT analysis showed a higher bone mineral density at the knee and femoral metaphysis in the vitamin E-treated group compared with uncoated implants (knee

  14. Metals for bone implants. Part 1. Powder metallurgy and implant rendering.

    PubMed

    Andani, Mohsen Taheri; Shayesteh Moghaddam, Narges; Haberland, Christoph; Dean, David; Miller, Michael J; Elahinia, Mohammad

    2014-10-01

    New metal alloys and metal fabrication strategies are likely to benefit future skeletal implant strategies. These metals and fabrication strategies were looked at from the point of view of standard-of-care implants for the mandible. These implants are used as part of the treatment for segmental resection due to oropharyngeal cancer, injury or correction of deformity due to pathology or congenital defect. The focus of this two-part review is the issues associated with the failure of existing mandibular implants that are due to mismatched material properties. Potential directions for future research are also studied. To mitigate these issues, the use of low-stiffness metallic alloys has been highlighted. To this end, the development, processing and biocompatibility of superelastic NiTi as well as resorbable magnesium-based alloys are discussed. Additionally, engineered porosity is reviewed as it can be an effective way of matching the stiffness of an implant with the surrounding tissue. These porosities and the overall geometry of the implant can be optimized for strain transduction and with a tailored stiffness profile. Rendering patient-specific, site-specific, morphology-specific and function-specific implants can now be achieved using these and other metals with bone-like material properties by additive manufacturing. The biocompatibility of implants prepared from superelastic and resorbable alloys is also reviewed. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. Radiology Resident Supply and Demand: A Regional Perspective.

    PubMed

    Pfeifer, Cory M

    2017-09-01

    Radiology was subject to crippling deficits in the number of jobs available to graduates of training programs from 2012 through 2015. As the specialty transitions to the assimilation of osteopathic training programs and the welcoming of direct competition from new integrated interventional radiology programs, the assessment of growth in radiology training positions over the 10 years preceding this pivotal time will serve to characterize the genesis of the crisis while inspiring stakeholders to avoid similar negative fluctuations in the future. The number of per capita radiology trainees in each region was derived from data published by the National Resident Matching Program, as were annual match statistics over the years 2012 through 2016. Data regarding new interventional radiology and diagnostic radiology enrollees were also obtained from the National Resident Matching Program. The seven states with the most per capita radiology residents were in the Mid-Atlantic and Northeastern United States in both 2006 and 2016, and three of these seven also showed the greatest per capita growth over the course of the 10 years studied. New radiology programs were accredited during the peak of the job shortage. Integrated interventional radiology training created 24 de novo radiology residents in the 2017 match. Fill rates are weakly positively correlated with program size. Unregulated radiology program growth persisted during the decade leading up to 2016. The region with the fewest jobs available since 2012 is also home to the greatest number of per capita radiology residents. Numerous published opinions during the crisis did not result in enforced policy change. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Microfracture technique versus carbon fibre rod implantation for treatment of knee articular cartilage lesions.

    PubMed

    Dasar, U; Gursoy, S; Akkaya, M; Algin, O; Isik, C; Bozkurt, M

    2016-08-01

    To compare the microfracture technique with carbon fibre rod implantation for treatment of knee articular cartilage lesions. 10 men and 30 women aged 22 to 56 (mean, 37.4) years underwent microfracture (n=20) or carbon fibre rod implantation (n=20) for International Cartilage Repair Society grade 3 to 4 knee articular cartilage lesions after a mean of 12.2 months of viscosupplementation and physiotherapy. Clinical outcome at 6 and 12 months was assessed using the Tegner-Lysholm score and modified Cincinnati score. Magnetic resonance imaging (MRI) outcome at 12 months was assessed by a radiologist. The modified magnetic resonance observation of cartilage repair tissue (MOCART) score was evaluated. The 2 groups were comparable in terms of age, body mass index, lesion location, lesion size, duration of symptoms, and coexisting pathology. The microfracture group had a higher preoperative Tegner-Lysholm score (39.4±7.3 vs. 34.4±4.9, p=0.015) and modified Cincinnati score (36.4±7.2 vs. 30.4±4.0, p=0.002) than the carbon fibre rod group. At 12 months, change in both scores was significant within each group (p<0.001) and was higher in the microfracture than carbon fibre rod group (p<0.001). MRI showed minimal regenerative tissue. Lobulation, oedema, and hypertrophy were more commonly found in the regeneration tissue after carbon fibre rod implantation than microfracture. At 12 months, the MOCART score was higher in the microfracture than carbon fibre rod group (59 vs. 47, p<0.001). Microfracture is superior to carbon fibre rod implantation in terms of clinical and radiological outcome.

  17. Group D. Initiator paper. Implants--peri-implant (hard and soft tissue) interactions in health and disease: the impact of explosion of implant manufacturers.

    PubMed

    Ivanovski, Saso

    2015-01-01

    1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.

  18. Cochlear Implants

    MedlinePlus

    ... newsroom@entnet.org . A cochlear implant is an electronic device that restores partial hearing to individuals with ... An internal component that consists of a small electronic device that is surgically implanted under the skin ...

  19. Goserelin Implant

    MedlinePlus

    Goserelin implant is used in combination with radiation therapy and other medications to treat localized prostate cancer ... and other symptoms) and to help with the treatment of abnormal bleeding of the uterus. Goserelin implant ...

  20. New orthopaedic implant management tool for computer-assisted planning, navigation, and simulation: from implant CAD files to a standardized XML-based implant database.

    PubMed

    Sagbo, S; Blochaou, F; Langlotz, F; Vangenot, C; Nolte, L-P; Zheng, G

    2005-01-01

    Computer-Assisted Orthopaedic Surgery (CAOS) has made much progress over the last 10 years. Navigation systems have been recognized as important tools that help surgeons, and various such systems have been developed. A disadvantage of these systems is that they use non-standard formalisms and techniques. As a result, there are no standard concepts for implant and tool management or data formats to store information for use in 3D planning and navigation. We addressed these limitations and developed a practical and generic solution that offers benefits for surgeons, implant manufacturers, and CAS application developers. We developed a virtual implant database containing geometrical as well as calibration information for orthopedic implants and instruments, with a focus on trauma. This database has been successfully tested for various applications in the client/server mode. The implant information is not static, however, because manufacturers periodically revise their implants, resulting in the deletion of some implants and the introduction of new ones. Tracking these continuous changes and keeping CAS systems up to date is a tedious task if done manually. This leads to additional costs for system development, and some errors are inevitably generated due to the huge amount of information that has to be processed. To ease management with respect to implant life cycle, we developed a tool to assist end-users (surgeons, hospitals, CAS system providers, and implant manufacturers) in managing their implants. Our system can be used for pre-operative planning and intra-operative navigation, and also for any surgical simulation involving orthopedic implants. Currently, this tool allows addition of new implants, modification of existing ones, deletion of obsolete implants, export of a given implant, and also creation of backups. Our implant management system has been successfully tested in the laboratory with very promising results. It makes it possible to fill the current gap

  1. Peri-implant bone density in senile osteoporosis-changes from implant placement to osseointegration.

    PubMed

    Beppu, Kensuke; Kido, Hirofumi; Watazu, Akira; Teraoka, Kay; Matsuura, Masaro

    2013-04-01

    The aim of this study was to examine healing over time after implant body placement in a senile osteoporosis model and a control group. In this study, 16-week-old male mice were used. The senile osteoporosis model consisted of senescence-accelerated prone 6 mice and the control group consisted of senescence-accelerated resistant 1 mice. Titanium-coated plastic implants were used as experimental implants whose dimensions were 3.0 mm in length, 1.1 mm in apical diameter, and 1.2 mm in coronal diameter. Bone samples were collected at 5, 7, 14, 21, and 28 days after implant placement. A micro-quantitative computed tomography (QCT) system was used to scan these samples and a phantom in order to quantitate bone mineral measurements. Bone mineral density (BMD) of each sample was measured. Each sample was also examined by light microscopy after QCT imaging. At 14 and 28 days after implant placement, the bone-implant contact (BIC) ratios were calculated from light microscopy images and were divided into cortical bone and bone marrow regions. When BMD was compared between the osteoporosis and control groups using micro-QCT, the osteoporosis group had a significantly lower BMD in the region 0-20 µm from the implant surface in the bone marrow region at 14 days onward after implant placement. Compared with the control group, the osteoporosis model also had significantly lower BMD in all regions 0-100 µm from the implant surface in the bone marrow region at 14 days after placement. However, in the cortical bone region, no statistically significant difference was observed in the regions at the bone-implant interface. Light microscopy revealed osseointegration for all implants 28 days after implant placement. The osteoporosis model tended to have lower BICs compared with that of the control group, although this did not reach statistical significance. Our results showed that osseointegration was achieved in the osteoporosis model. However, the BMD was 30-40% lower than that of

  2. Clinical and Aesthetic Outcome with Post-Extractive Implants with or without Soft Tissue Augmentation: A 2-Year Randomized Clinical Trial.

    PubMed

    Migliorati, Marco; Amorfini, Leonardo; Signori, Alessio; Biavati, Armando Silvestrini; Benedicenti, Stefano

    2015-10-01

    The aesthetic outcome of an implant-supported restoration is first of all dependent on the soft tissue volume. Because the labial bone plate resorbs in every direction after tooth extraction, even when an implant is placed immediately, most patients end up with compromised aesthetics. In this parallel-designed, randomized clinical trial, participants were randomly assigned to the test group (immediate load post-extractive implant treated with subepithelial connective tissue graft placed using the tunnel technique in the labial area) and control group (immediate load post-extractive implant treated without raising a flap) with an allocation ratio of 1:1. Both groups received deproteinized bovine bone mineral. Patients were observed at baseline, crown insertion, 1-year follow-up, and 2-year follow-up. Clinical, radiological and aesthetic parameters were recorded to assess primary treatment outcomes. A random permuted block system was blindly generated ensuring uniformity of the patient allocation during the trial by randomly distributing three participants to the test and three participants to the control group every six treated patients. At the 2-year examination, all 47 implants were successfully integrated, demonstrating stability and healthy peri-implant soft tissues as documented by standard clinical parameters. The results showed a soft tissue remodeling of -10% in thickness and -18% in highness in the non-grafted group, whereas in the grafted group there was a gain of 35% in thickness and a slight reduction of -11% in highness. Test group reported an increase of aesthetic result (mean pink aesthetic score [PES] 8) compared with control group (mean PES 6.65). This prospective study demonstrates the effectiveness of placing a soft tissue graft at the time of immediate implant placement in the aesthetic zone. At the 2-year follow-up, test group revealed a better aesthetic outcomes and stable facial soft tissues compared with control group. © 2013 Wiley

  3. Sacroiliac joint stability: Finite element analysis of implant number, orientation, and superior implant length

    PubMed Central

    Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K

    2018-01-01

    AIM To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. METHODS An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System®). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. RESULTS Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. CONCLUSION Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results. PMID:29564210

  4. Individual titanium zygomatic implant

    NASA Astrophysics Data System (ADS)

    Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.

    2018-03-01

    Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.

  5. Impact of early complications on outcomes in patients with implantable cardioverter-defibrillator for primary prevention.

    PubMed

    Ascoeta, Maria Soledad; Marijon, Eloi; Defaye, Pascal; Klug, Didier; Beganton, Frankie; Perier, Marie-Cécile; Gras, Daniel; Algalarrondo, Vincent; Deharo, Jean-Claude; Leclercq, Christophe; Fauchier, Laurent; Babuty, Dominique; Bordachar, Pierre; Sadoul, Nicolas; Boveda, Serge; Piot, Olivier

    2016-05-01

    The lifesaving benefit of implantable cardioverter-defibrillators (ICDs) has been demonstrated. Their use has increased considerably in the past decade, but related complications have become a major concern. The purpose of this study was to assess the incidence and effect on outcomes of early (≤30 days) complications after ICD implantation for primary prevention in a large French population. We analyzed data from 5539 patients from the multicenter French DAI-PP (Défibrillateur Automatique Implantable-Prévention Primaire) registry (2002-2012) who had coronary artery disease or dilated cardiomyopathy and were implanted with an ICD for primary prevention. Overall, early complications occurred in 707 patients (13.5%), mainly related to lead dislodgment or hematoma (57%). Independent factors associated with occurrence of early complications were severe renal impairment (odds ratio [OR] 1.66, 95% confidence interval [CI] 1.17-2.37, P = .02), age ≥75 years (OR 1.01, 95% CI 1.00-1.02, P = .03), cardiac resynchronization therapy (OR 1.58, 95% CI 1.16-2.17, P = .01), and anticoagulant therapy (OR 1.28, 95% CI 1.02-1.61, P = .03). During a mean ± SD follow-up of 3.1 ± 2.3 years, 824 (15.8%) patients experienced ≥1 late complication (>30 days), and 782 (14.9%) patients died. After adjustment, early complications remained associated with occurrence of late complications (OR 2.15, 95% CI 1.73-2.66, P < .0001) and mortality (OR 1.70, 95% CI 1.34-2.17, P = .003). Early complications are common after ICD implantation for primary prevention, occurring in 1 in 7 patients, and are associated with an increased risk of late complications and overall mortality. Further studies are needed to investigate the underlying mechanisms of such associations. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  6. Radiologic and functional evaluation of electrode dislocation from the scala tympani to the scala vestibuli in patients with cochlear implants.

    PubMed

    Fischer, N; Pinggera, L; Weichbold, V; Dejaco, D; Schmutzhard, J; Widmann, G

    2015-02-01

    Localization of the electrode after cochlear implantation seems to have an impact on auditory outcome, and conebeam CT has emerged as a reliable method for visualizing the electrode array position within the cochlea. The aim of this retrospective study was to evaluate the frequency and clinical impact of scalar dislocation of various electrodes and surgical approaches and to evaluate its influence on auditory outcome. This retrospective single-center study analyzed a consecutive series of 63 cochlear implantations with various straight electrodes. The placement of the electrode array was evaluated by using multiplanar reconstructed conebeam CT images. For the auditory outcome, we compared the aided hearing thresholds and the charge units of maximum comfortable loudness level at weeks 6, 12, and 24 after implantation. In 7.9% of the cases, the electrode array showed scalar dislocation. In all cases, the electrode array penetrated the basal membrane within 45° of the electrode insertion. All 3 cases of cochleostomy were dislocated in the first 45° segment. No hearing differences were noted, but the charge units of maximum comfortable loudness level seemed to increase with time in patients with dislocations. The intracochlear dislocation rate of various straight electrodes detected by conebeam CT images is relatively low. Scalar dislocation may not negatively influence the hearing threshold but may require an increase of the necessary stimulus charge and should be reported by the radiologist. © 2015 by American Journal of Neuroradiology.

  7. Regional ontogeny of New England salt marsh die-off.

    PubMed

    Coverdale, Tyler C; Bertness, Mark D; Altieri, Andrew H

    2013-10-01

    Coastal areas are among the world's most productive and highly affected ecosystems. Centuries of human activity on coastlines have led to overexploitation of marine predators, which in turn has led to cascading ecosystem-level effects. Human effects and approaches to mediating them, however, differ regionally due to gradients in biotic and abiotic factors. Salt marsh die-off on Cape Cod, Massachusetts (U.S.A.), triggered by a recreational-fishing-induced trophic cascade that has released herbivorous crabs from predator control, has been ongoing since 1976. Similar salt marsh die-offs have been reported in Long Island Sound and Narragansett Bay (U.S.A.), but the driving mechanism of these die-offs has not been examined. We used field experiments to assess trophic interactions and historical reconstructions of 24 New England marshes to test the hypotheses that recreational fishing and predator depletion are a regional trigger of salt marsh die-off in New England and that die-offs in Long Island Sound and Narragansett Bay are more recent than those on Cape Cod. Predator depletion was the general trigger of marsh die-off and explained differences in herbivorous crab abundance and the severity of die-off across regions. Die-offs in Long Island Sound and Narragansett Bay are following a trajectory similar to die-off on Cape Cod, but are approximately 20 years behind those on Cape Cod. As a result, die-off currently affects 31.2% (SE 2.2) of low-marsh areas in Long Island Sound and Narragansett Bay, less than half the severity of die-off on Cape Cod. Our results contribute to the growing evidence that recreational fishing is an increasing threat to coastal ecosystems and that studying the effects of human activity at regional scales can provide insight into local effects and aid in early detection and potential remediation. © 2013 Society for Conservation Biology.

  8. The effects of implant angulation on the resonance frequency of a dental implant.

    PubMed

    Harirforoush, R; Arzanpour, S; Chehroudi, B

    2014-08-01

    Dental implants are ideally placed in an orientation that allows vertical transfer of occlusal forces along their long axis. Nevertheless, optimal situations for implant placement are seldom encountered resulting in implants placement in angulated positions, which may affect their long-term success. The resonance frequency (RF) is an objective tool used to monitor stability of the implant tissue integration; however, little is known of the effect of the implant orientation in bone on the RF and its potential significance. The purpose of this research was to determine the relation between the dental implant orientation and the corresponding RF of implant. Three-dimensional (3D) modelling software was used to construct a 3D model of a pig mandible from computed tomography (CT) images. The RF of the implant was analysed using finite element (FE) modal analysis in software ANSYS (v.12). In addition, a cubical model was also developed in MIMICS to investigate the parameters affecting the relationship between RF and implant orientation in a simplified environment. The orientation angle was increased from 0 to 10 degrees in 1 degree increments and the resulting RF was analysed using correlation analysis and one-way ANOVA. Our analysis illustrated that the RF fluctuation following altering implant orientation was strongly correlated (r=0.97) with the contacting cortical to cancellous bone ratio (CCBR) at the implant interface. The most extreme RF change (from 9.81kHz to 10.07kHz) occurred when the implant was moved 0.5mm in positive z-direction, which resulted in the maximum change of CCBR from 52.9 to 54.8. Copyright © 2014. Published by Elsevier Ltd.

  9. DEALING WITH DENTAL IMPLANT FAILURES

    PubMed Central

    Levin, Liran

    2008-01-01

    An implant-supported restoration offers a predictable treatment for tooth replacement. Reported success rates for dental implants are high. Nevertheless, failures that mandate immediate implant removal do occur. The consequences of implant removal jeopardize the clinician's efforts to accomplish satisfactory function and esthetics. For the patient, this usually involves further cost and additional procedures. The aim of this paper is to describe different methods and treatment modalities to deal with dental implant failure. The main topics for discussion include identifying the failing implant, implants replacing failed implants at the exact site, and the use of other restorative options. When an implant fails, a tailor made treatment plan should be provided to each patient according to all relevant variables. Patients should be informed regarding all possible treatment modalities following implant failure and give their consent to the most appropriate treatment option for them. PMID:19089213

  10. 21 CFR 892.1940 - Radiologic quality assurance instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiologic quality assurance instrument. 892.1940... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1940 Radiologic quality assurance instrument. (a) Identification. A radiologic quality assurance instrument is a device intended for medical...

  11. Discoloration of the Peri-implant Mucosa Caused by Zirconia and Titanium Implants.

    PubMed

    Thoma, Daniel S; Ioannidis, Alexis; Cathomen, Elena; Hämmerle, Christoph H F; Hüsler, Jürg; Jung, Ronald E

    2016-01-01

    The aim of the present study was to assess the discoloration of the peri-implant mucosa caused by zirconia (Zr) and titanium (Ti) dental implants with and without soft tissue grafting (STG). Zr and Ti implants were inserted in edentulous areas in pig maxillae. Spectrophotometric measurements were performed prior to and after the insertion of the implants, and following the placement of a STG on the buccal side. A significant discoloration of the mucosa was observed with a mean ΔE of 8.05 (± 2.51) (Ti) and 4.93 (± 3.18) (Zr). In conjunction with a STG, ΔE values amounted to 5.31 ± 3.50 (Ti) and 5.95 (± 3.68) (Zr). The placement of Zr implants led to less discoloration of the mucosa than Ti implants without STG.

  12. Dental Implant Systems

    PubMed Central

    Oshida, Yoshiki; Tuna, Elif B.; Aktören, Oya; Gençay, Koray

    2010-01-01

    Among various dental materials and their successful applications, a dental implant is a good example of the integrated system of science and technology involved in multiple disciplines including surface chemistry and physics, biomechanics, from macro-scale to nano-scale manufacturing technologies and surface engineering. As many other dental materials and devices, there are crucial requirements taken upon on dental implants systems, since surface of dental implants is directly in contact with vital hard/soft tissue and is subjected to chemical as well as mechanical bio-environments. Such requirements should, at least, include biological compatibility, mechanical compatibility, and morphological compatibility to surrounding vital tissues. In this review, based on carefully selected about 500 published articles, these requirements plus MRI compatibility are firstly reviewed, followed by surface texturing methods in details. Normally dental implants are placed to lost tooth/teeth location(s) in adult patients whose skeleton and bony growth have already completed. However, there are some controversial issues for placing dental implants in growing patients. This point has been, in most of dental articles, overlooked. This review, therefore, throws a deliberate sight on this point. Concluding this review, we are proposing a novel implant system that integrates materials science and up-dated surface technology to improve dental implant systems exhibiting bio- and mechano-functionalities. PMID:20480036

  13. Comparison of Reconstructive Outcomes in Breast Cancer Patients With Preexisting Subpectoral Implants: Implant-Sparing Mastectomy With Delayed Implant Exchange Versus Immediate Tissue Expander Reconstruction.

    PubMed

    Parabkaharan, Sangeetha; Melody, Megan; Trotta, Rose; Lleshi, Amina; Sun, Weihong; Smith, Paul D; Khakpour, Nazanin; Dayicioglu, Deniz

    2016-06-01

    Women who have undergone prior augmentation mammoplasty represent a unique subset of breast cancer patients with several options available for breast reconstruction. We performed a single institution review of surgical outcomes of breast reconstruction performed in patients with breast cancer with prior history of subpectoral breast augmentation. Institutional review board-approved retrospective review was conducted among patients with previously mentioned criteria treated at our institution between 2000 and 2014. Reconstructions were grouped into 2 categories as follows: (1) removal of preexisting subpectoral implant during mastectomy with immediate tissue expander placement and (2) implant-sparing mastectomy followed by delayed exchange to a larger implant. We reviewed demographics, tumor features, and reconstruction outcomes of these groups. Fifty-three patients had preexisting subpectoral implants. Of the 63 breast reconstructions performed, 18 (28.6%) had immediate tissue expander placed and 45 (71.4%) had implant-sparing mastectomy followed by delayed implant exchange. The groups were comparable based on age, body mass index, cancer type, tumor grade, TNM stage at presentation, and hormonal receptor status. No significant difference was noted between tumor margins or subsequent recurrence, mastectomy specimen weight, removed implant volume, volume of implant placed during reconstruction, or time from mastectomy to final implant placement. Rates of complications were significantly higher in the tissue expander group compared to the implant-sparing mastectomy group 7 (38.9%) versus 4 (8.9%) (P = 0.005). Implant-sparing mastectomy with delayed implant exchange in patients with preexisting subpectoral implants is safe and has fewer complications compared to tissue expander placement. There was no difference noted in the final volume of implant placed, time interval for final implant placement, or tumor margins.

  14. Implant ethics

    PubMed Central

    Hansson, S

    2005-01-01

    Implant ethics is defined here as the study of ethical aspects of the lasting introduction of technological devices into the human body. Whereas technological implants relieve us of some of the ethical problems connected with transplantation, other difficulties arise that are in need of careful analysis. A systematic approach to implant ethics is proposed. The major specific problems are identified as those concerning end of life issues (turning off devices), enhancement of human capabilities beyond normal levels, mental changes and personal identity, and cultural effects. PMID:16131553

  15. 25 CFR 304.5 - Dies to identify tribe.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 2 2014-04-01 2014-04-01 false Dies to identify tribe. 304.5 Section 304.5 Indians INDIAN ARTS AND CRAFTS BOARD, DEPARTMENT OF THE INTERIOR NAVAJO, PUEBLO, AND HOPI SILVER, USE OF GOVERNMENT MARK § 304.5 Dies to identify tribe. Dies are marked with name of tribe. A Navajo stamp will be...

  16. 25 CFR 304.5 - Dies to identify tribe.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 2 2011-04-01 2011-04-01 false Dies to identify tribe. 304.5 Section 304.5 Indians INDIAN ARTS AND CRAFTS BOARD, DEPARTMENT OF THE INTERIOR NAVAJO, PUEBLO, AND HOPI SILVER, USE OF GOVERNMENT MARK § 304.5 Dies to identify tribe. Dies are marked with name of tribe. A Navajo stamp will be...

  17. 25 CFR 304.5 - Dies to identify tribe.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 2 2012-04-01 2012-04-01 false Dies to identify tribe. 304.5 Section 304.5 Indians INDIAN ARTS AND CRAFTS BOARD, DEPARTMENT OF THE INTERIOR NAVAJO, PUEBLO, AND HOPI SILVER, USE OF GOVERNMENT MARK § 304.5 Dies to identify tribe. Dies are marked with name of tribe. A Navajo stamp will be...

  18. 25 CFR 304.5 - Dies to identify tribe.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 2 2013-04-01 2013-04-01 false Dies to identify tribe. 304.5 Section 304.5 Indians INDIAN ARTS AND CRAFTS BOARD, DEPARTMENT OF THE INTERIOR NAVAJO, PUEBLO, AND HOPI SILVER, USE OF GOVERNMENT MARK § 304.5 Dies to identify tribe. Dies are marked with name of tribe. A Navajo stamp will be...

  19. Effect of implant design and bioactive glass coating on biomechanical properties of fiber-reinforced composite implants.

    PubMed

    Ballo, Ahmed M; Akca, Eralp; Ozen, Tuncer; Moritz, Niko; Lassila, Lippo; Vallittu, Pekka; Närhi, Timo

    2014-08-01

    This study aimed to evaluate the influence of implant design and bioactive glass (BAG) coating on the response of bone to fiber-reinforced composite (FRC) implants. Three different FRC implant types were manufactured for the study: non-threaded implants with a BAG coating; threaded implants with a BAG coating; and threaded implants with a grit-blasted surface. Thirty-six implants (six implants for each group per time point) were installed in the tibiae of six pigs. After an implantation period of 4 and 12 wk, the implants were retrieved and prepared for micro-computed tomography (micro-CT), push-out testing, and scanning electron microscopy analysis. Micro-CT demonstrated that the screw-threads and implant structure remained undamaged during the installation. The threaded FRC/BAG implants had the highest bone volume after 12 wk of implantation. The push-out strengths of the threaded FRC/BAG implants after 4 and 12 wk (463°N and 676°N, respectively) were significantly higher than those of the threaded FRC implants (416°N and 549°N, respectively) and the nonthreaded FRC/BAG implants (219°N and 430°N, respectively). Statistically significant correlation was found between bone volume and push-out strength values. This study showed that osseointegrated FRC implants can withstand the static loading up to failure without fracture, and that the addition of BAG significantly improves the push-out strength of FRC implants. © 2014 Eur J Oral Sci.

  20. Peri-implant plastic surgery techniques to hard and soft tissue augmentation in implant rehabilitation

    PubMed Central

    Baltacioğlu, Esra; Korkmaz, Yavuz Tolga; Korkmaz, Fatih Mehmet; Aydin, Güven; Sukuroglu, Erkan

    2017-01-01

    This report presents the clinical results of peri-implant plastic surgical approaches for hard and soft tissues before and during the implant placement in a patient with vertical ridge deformation and a shallow vestibule sulcus, and the subsequently performed prosthetic rehabilitation. The surgical approaches used in this case reduced the crown-height space and crown-to-implant ratio and ensured that the implants were placed in their ideal positions, and peri-implant tissue health was maintained. In conclusion, developments in the peri-implant plastic surgery enable the successful augmentation of hard and soft tissue defects and provide the implant-supported fixed prosthetic rehabilitation. PMID:29386805

  1. Clinical operations management in radiology.

    PubMed

    Ondategui-Parra, Silvia; Gill, Ileana E; Bhagwat, Jui G; Intrieri, Lisa A; Gogate, Adheet; Zou, Kelly H; Nathanson, Eric; Seltzer, Steven E; Ros, Pablo R

    2004-09-01

    Providing radiology services is a complex and technically demanding enterprise in which the application of operations management (OM) tools can play a substantial role in process management and improvement. This paper considers the benefits of an OM process in a radiology setting. Available techniques and concepts of OM are addressed, along with gains and benefits that can be derived from these processes. A reference framework for the radiology processes is described, distinguishing two phases in the initial assessment of a unit: the diagnostic phase and the redesign phase.

  2. Assisted dying - should the UK change its stance?

    PubMed

    Gordon, Daniel; Raphael, Claire E; Vassiliou, Vassilios

    2015-04-01

    Along with an increasing interest in assisted dying by many European and North American countries, some of which have already modified their existing laws to accommodate this, the interest in assisted dying in the UK has increased once again following Lord Falconer's Assisted Dying for the Terminally Ill Bill. Drawing on examples from countries where similar assisted dying laws are already in place, this article analyses and contextualises the proposed bill and discusses its potential pitfalls and benefits for the UK. © The European Society of Cardiology 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Meditations on the unitary rhythm of dying-grieving.

    PubMed

    Malinski, Violet M

    2012-07-01

    When someone faces loss of a loved one, that person simultaneously grieves and dies a little, just as the one dying also grieves. The author's personal conceptualization of dying and grieving as a unitary rhythm is explored based primarily on her interpretation of Rogers' science of unitary human beings, along with selected examples from related nursing literature and from the emerging focus on continuing bonds in other disciplines. Examples from contemporary songwriters that depict such a unitary conceptualization are given along with personal examples. The author concludes with her description of the unitary rhythm of dying-grieving.

  4. The clinical implications of poly implant prothèse breast implants: an overview.

    PubMed

    Wazir, Umar; Kasem, Abdul; Mokbel, Kefah

    2015-01-01

    Mammary implants marketed by Poly Implant Prothèse (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Prothèse", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.

  5. The Clinical Implications of Poly Implant Prothèse Breast Implants: An Overview

    PubMed Central

    Wazir, Umar; Kasem, Abdul

    2015-01-01

    Mammary implants marketed by Poly Implant Prothèse (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Prothèse", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage. PMID:25606483

  6. Will the UK Supreme Court allow assisted dying?

    PubMed

    Griffith, Richard

    MPs overwhelmingly voted against passing the Assisted Dying Bill into law in September 2015. The Bill was defeated by a majority of 212, despite the heartfelt pleas of many MPs to pass it into law. The size of the defeat means that it is unlikely that Parliament will consider a similar law for many years. Yet many considered the Bill their last opportunity to make assisted dying lawful. There is, however, one further possible way assisted dying could become lawful in the UK--and that would be where the Supreme Court allowed it. In this article, the author reviews the Supreme Court's decision in R (on the application of Nicklinson v Ministry of Justice [2014] and considers how likely it is that the Supreme Court will now sanction assisted dying following Parliament's refusal to enact an assisted dying law.

  7. Maxillary sinus by-pass with tilted implants via tapered-screw bone expanders in low density bone: one year follow -up of a case series.

    PubMed

    Andreasi Bassi, M; Andrisani, C; Lopez, M A; Gaudio, R M; Lombardo, L; Lauritano, D

    2016-01-01

    In the present paper the use of tapered-screw bone expanders (TSBEs) is proposed, in combination with the placement of tilted implants in close proximity to the anterior sinus wall, solving the problem of the reduced height of the alveolar bone in the sub-antral area. The Authors named the procedure: Tilted Implant Expansion Osteotomy (TIEO). Fifteen patients (10 females and 5 males, mean age 47.8±8.15 years) with distal edentulous maxillae were enrolled in this study. For each edentulous site 2 implants were placed, the anterior implant in the area of the most anterior missing tooth while, the posterior implant, immediately in front of the maxillary sinus, with an inclined position. Adopting the aforesaid procedure, 34 cylindrical two-piece implants were placed, 17 of which were placed in tilted position, in order to by-pass the maxillary sinus. After a healing period of 4-6 months, the second stage surgery was performed. The cases were finalized by metal-ceramic cementable restorations with a variable number of elements, from 2 to 4, without any cantilever element. The post finalization follow-up was at 12 months. Survival rate was 100% since no fixtures were lost. At the one-year follow-up the clinical and radiological appearance of the soft and hard tissues was optimal and no pathological signs were recorded. TIEO is a promising surgical procedure for oral rehabilitation of maxillary edentulous sites and represents a therapeutic alternative to sinus lift techniques.

  8. CO2 laser surface treatment of failed dental implants for re-implantation: an animal study.

    PubMed

    Kasraei, Shahin; Torkzaban, Parviz; Shams, Bahar; Hosseinipanah, Seyed Mohammad; Farhadian, Maryam

    2016-07-01

    The aim of the present study was to evaluate the success rate of failed implants re-implanted after surface treatment with CO2 laser. Despite the widespread use of dental implants, there are many incidents of failures. It is believed that lasers can be applied to decontaminate the implant surface without damaging the implant. Ten dental implants that had failed for various reasons other than fracture or surface abrasion were subjected to CO2 laser surface treatment and randomly placed in the maxillae of dogs. Three failed implants were also placed as the negative controls after irrigation with saline solution without laser surface treatment. The stability of the implants was evaluated by the use of the Periotest values (PTVs) on the first day after surgery and at 1, 3, and 6 months post-operatively. The mean PTVs of treated implants increased at the first month interval, indicating a decrease in implant stability due to inflammation followed by healing of the tissue. At 3 and 6 months, the mean PTVs decreased compared to the 1-month interval (P < 0.05), indicating improved implant stability. The mean PTVs increased in the negative control group compared to baseline (P < 0.05). Independent t-test showed that the mean PTVs of treated implants were significantly lower than control group at 3 and 6 months after implant placement (P < 0.05). Based on the PTVs, re-implantation of failed implants in Jack Russell Terrier dogs after CO2 laser surface debridement is associated with a high success rate in terms of implant stability.

  9. An in vivo assessment of the effects of using different implant abutment occluding materials on implant microleakage and the peri-implant microbiome

    NASA Astrophysics Data System (ADS)

    Rubino, Caroline

    Microleakage may be a factor in the progression of peri-implant pathology. Microleakage in implant dentistry refers to the passage of bacteria, fluids, molecules or ions between the abutment-implant interface to and from the surrounding periodontal tissues. This creates a zone of inflammation and reservoir of bacteria at the implant-abutment interface. Bone loss typically occurs within the first year of abutment connection and then stabilizes. It has not yet been definitively proven that the occurrence of microleakage cannot contribute to future bone loss or impede the treatment of peri-implant disease. Therefore, strategies to reduce or eliminate microleakage are sought out. Recent evidence demonstrates that the type of implant abutment channel occluding material can affect the amount of microleakage in an in vitro study environment. Thus, we hypothesize that different abutment screw channel occluding materials will affect the amount of observed microleakage, vis-a-vis the correlation between the microflora found on the abutment screw channel occluding material those found in the peri-implant sulcus. Additional objectives include confirming the presence of microleakage in vivo and assessing any impact that different abutment screw channel occluding materials may have on the peri-implant microbiome. Finally, the present study provides an opportunity to further characterize the peri-implant microbiome. Eight fully edentulous patients restored with at dental implants supporting screw-retained fixed hybrid prostheses were included in the study. At the initial appointment (T1), the prostheses were removed and the implants and prostheses were cleaned. The prostheses were then inserted with polytetrafluoroethylene tape (PTFE, TeflonRTM), cotton, polyvinyl siloxane (PVS), or synthetic foam as the implant abutment channel occluding material and sealed over with composite resin. About six months later (T2), the prostheses were removed and the materials collected. Paper

  10. Trends in Cochlear Implants

    PubMed Central

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management. PMID:15247993

  11. Trends in cochlear implants.

    PubMed

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  12. Micro-cutting of silicon implanted with hydrogen and post-implantation thermal treatment

    NASA Astrophysics Data System (ADS)

    Jelenković, Emil V.; To, Suet; Sundaravel, B.; Xiao, Gaobo; Huang, Hu

    2016-07-01

    It was reported that non-amorphizing implantation by hydrogen has a potential in improving silicon machining. Post-implantation high-temperature treatment will affect implantation-induced damage, which can have impact on silicon machining. In this article, a relation of a thermal annealing of hydrogen implanted in silicon to micro-cutting experiment is investigated. Hydrogen ions were implanted into 4″ silicon wafers with 175 keV, 150 keV, 125 keV and doses of 2 × 1016 cm-2, 2 × 1016 cm-2 and 3 × 1016 cm-2, respectively. In this way, low hydrogen atom-low defect concentration was created in the region less than ~0.8 μm deep and high hydrogen atom-high defect concentration was obtained at silicon depth of ~0.8-1.5 μm. The post-implantation annealing was carried out at 300 and 400 °C in nitrogen for 1 h. Physical and electrical properties of implanted and annealed samples were characterized by secondary ion mass spectroscopy (SIMS), X-ray diffraction (XRD), Rutherford backscattering (RBS) and nanoindentation. Plunge cutting experiment was carried out in <110> and <100> silicon crystal direction. The critical depth of cut and cutting force were monitored and found to be influenced by the annealing. The limits of hydrogen implantation annealing contribution to the cutting characteristics of silicon are discussed in light of implantation process and redistribution of hydrogen and defects generation during annealing process.

  13. Upper full arch rehabilitation with sinus by-pass with tilted implants via tapered-threaded expanders in low density bone: a clinical trial

    PubMed Central

    BASSI, M. ANDREASI; ANDRISANI, C.; LICO, S.; ORMANIER, Z.; ARCURI, C.

    2016-01-01

    SUMMARY Purpose In the present paper the use of tapered-screw bone expanders (TSBEs) is proposed, in combination with the placement of tilted implants, in close proximity to the anterior sinus wall, solving the problem of the reduced height of the alveolar bone in the sub-antral area. The Authors present a case series of full-arch rehabilitations performed with this procedure named: Tilted Implant Expansion Osteotomy (TIEO). Materials and methods 12 patients (5 males and 7 females, average age 58.5 ± 8.1 years) with totally or partially edentulous maxilla were enrolled in this study. For each patient 4 implants were placed, the anterior implants in the area of lateral incisors or canines while, the posterior implants, immediately in front of the maxillary sinus, with an inclined position. Adopting the aforesaid procedure, 48 cylindrical two-piece implants were placed, 24 of which were placed in tilted position, in order to by-pass the maxillary sinus. After a healing period of 6 months, the second stage surgery was performed. The cases were finalized by means of a hybrid metal-acrylic prosthesis. The post finalization follow-up was at 12 months. Results Survival rate was 100% since none fixtures were lost. At the one-year follow up the clinical and radiological appearance of the soft and hard tissues was optimal and no pathological signs were recorded. Conclusion TIEO is a promising surgical procedure for full-arch rehabilitation of maxillary edentulous sites and represents a therapeutic alternative to sinus lift techniques. PMID:28042432

  14. Implantable Heart Aid

    NASA Technical Reports Server (NTRS)

    1984-01-01

    CPI's human-implantable automatic implantable defibrillator (AID) is a heart assist system, derived from NASA's space circuitry technology, that can prevent erratic heart action known as arrhythmias. Implanted AID, consisting of microcomputer power source and two electrodes for sensing heart activity, recognizes onset of ventricular fibrillation (VF) and delivers corrective electrical countershock to restore rhythmic heartbeat.

  15. Chimeric Peptides as Implant Functionalization Agents for Titanium Alloy Implants with Antimicrobial Properties

    NASA Astrophysics Data System (ADS)

    Yucesoy, Deniz T.; Hnilova, Marketa; Boone, Kyle; Arnold, Paul M.; Snead, Malcolm L.; Tamerler, Candan

    2015-04-01

    Implant-associated infections can have severe effects on the longevity of implant devices and they also represent a major cause of implant failures. Treating these infections associated with implants by antibiotics is not always an effective strategy due to poor penetration rates of antibiotics into biofilms. Additionally, emerging antibiotic resistance poses serious concerns. There is an urge to develop effective antibacterial surfaces that prevent bacterial adhesion and proliferation. A novel class of bacterial therapeutic agents, known as antimicrobial peptides (AMPs), are receiving increasing attention as an unconventional option to treat septic infection, partly due to their capacity to stimulate innate immune responses and for the difficulty of microorganisms to develop resistance towards them. While host and bacterial cells compete in determining the ultimate fate of the implant, functionalization of implant surfaces with AMPs can shift the balance and prevent implant infections. In the present study, we developed a novel chimeric peptide to functionalize the implant material surface. The chimeric peptide simultaneously presents two functionalities, with one domain binding to a titanium alloy implant surface through a titanium-binding domain while the other domain displays an antimicrobial property. This approach gains strength through control over the bio-material interfaces, a property built upon molecular recognition and self-assembly through a titanium alloy binding domain in the chimeric peptide. The efficiency of chimeric peptide both in-solution and absorbed onto titanium alloy surface was evaluated in vitro against three common human host infectious bacteria, Streptococcus mutans, Staphylococcus epidermidis, and Escherichia coli. In biological interactions such as occur on implants, it is the surface and the interface that dictate the ultimate outcome. Controlling the implant surface by creating an interface composed chimeric peptides may therefore

  16. Chimeric peptides as implant functionalization agents for titanium alloy implants with antimicrobial properties.

    PubMed

    Yucesoy, Deniz T; Hnilova, Marketa; Boone, Kyle; Arnold, Paul M; Snead, Malcolm L; Tamerler, Candan

    2015-04-01

    Implant-associated infections can have severe effects on the longevity of implant devices and they also represent a major cause of implant failures. Treating these infections associated with implants by antibiotics is not always an effective strategy due to poor penetration rates of antibiotics into biofilms. Additionally, emerging antibiotic resistance poses serious concerns. There is an urge to develop effective antibacterial surfaces that prevent bacterial adhesion and proliferation. A novel class of bacterial therapeutic agents, known as antimicrobial peptides (AMP's), are receiving increasing attention as an unconventional option to treat septic infection, partly due to their capacity to stimulate innate immune responses and for the difficulty of microorganisms to develop resistance towards them. While host- and bacterial- cells compete in determining the ultimate fate of the implant, functionalization of implant surfaces with antimicrobial peptides can shift the balance and prevent implant infections. In the present study, we developed a novel chimeric peptide to functionalize the implant material surface. The chimeric peptide simultaneously presents two functionalities, with one domain binding to a titanium alloy implant surface through a titanium-binding domain while the other domain displays an antimicrobial property. This approach gains strength through control over the bio-material interfaces, a property built upon molecular recognition and self-assembly through a titanium alloy binding domain in the chimeric peptide. The efficiency of chimeric peptide both in-solution and absorbed onto titanium alloy surface was evaluated in vitro against three common human host infectious bacteria, S. mutans, S. epidermidis , and E. coli . In biological interactions such as occurs on implants, it is the surface and the interface that dictate the ultimate outcome. Controlling the implant surface by creating an interface composed chimeric peptides may therefore open up

  17. Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level.

    PubMed

    Šćepanović, Miodrag; Todorović, Aleksandar; Marković, Aleksa; Patrnogić, Vesna; Miličić, Biljana; Moufti, Adel M; Mišić, Tijana

    2015-05-01

    This 1-year cohort study investigated stability and peri-implant marginal bone level of immediately loaded mini dental implants used to retain overdentures. Each of 30 edentulous patients received 4 mini dental implants (1.8 mm × 13 mm) in the interforaminal mandibular region. The implants were immediately loaded with pre-made overdentures. Outcome measures included implant stability and bone resorption. Implant stability was measured using the Periotest Classic(®) device immediately after placement and on the 3rd and 6th weeks and the 4th, 6th and 12th months postoperatively. The peri-implant marginal bone level (PIBL) was evaluated at the implant's mesial and distal sides from the polished platform to the marginal crest. Radiographs were taken using a tailored film holder to reproducibly position the X-ray tube at the 6th week, 4th and 12th months postoperatively. The primary stability (Periotest value, PTV) measured -0.27 ± 3.41 on a scale of -8 to + 50 (lower PTV reflects higher stability). The secondary stability decreased significantly until week 6 (mean PTV = 7.61 ± 7.05) then increased significantly reaching (PTV = 6.17 ± 6.15) at 12 months. The mean PIBL measured -0.40 mm after 1 year of functional loading, with no statistically significant differences at the various follow-ups (p = 0.218). Mini dental implants placed into the interforaminal region could achieve a favorable primary stability for immediate loading. The follow-up Periotest values fluctuated, apparently reflecting the dynamics of bone remodeling, with the implants remaining clinically stable (98.3%) after 1 year of function. The 1-year bone resorption around immediately loaded MDIs is within the clinically acceptable range for standard implants. Copyright © 2014 Elsevier GmbH. All rights reserved.

  18. In vitro assessment of tissue heating near metallic medical implants by exposure to pulsed radio frequency diathermy

    NASA Astrophysics Data System (ADS)

    Ruggera, P. S.; Witters, D. M.; von Maltzahn, G.; Bassen, H. I.

    2003-09-01

    A patient with bilateral implanted neurostimulators suffered significant brain tissue damage, and subsequently died, following diathermy treatment to hasten recovery from teeth extraction. Subsequent MRI examinations showed acute deterioration of the tissue near the deep brain stimulator (DBS) lead's electrodes which was attributed to excessive tissue heating induced by the diathermy treatment. Though not published in the open literature, a second incident was reported for a patient with implanted neurostimulators for the treatment of Parkinson's disease. During a diathermy treatment for severe kyphosis, the patient had a sudden change in mental status and neurological deficits. The diathermy was implicated in causing damage to the patient's brain tissue. To investigate if diathermy induced excessive heating was possible with other types of implantable lead systems, or metallic implants in general, we conducted a series of in vitro laboratory tests. We obtained a diathermy unit and also assembled a controllable laboratory exposure system. Specific absorption rate (SAR) measurements were performed using fibre optic thermometry in proximity to the implants to determine the rate of temperature rise using typical diathermy treatment power levels. Comparisons were made of the SAR measurements for a spinal cord stimulator (SCS) lead, a pacemaker lead and three types of bone prosthesis (screws, rods and a plate). Findings indicate that temperature changes of 2.54 and 4.88 °C s-1 with corresponding SAR values of 9129 and 17 563 W kg-1 near the SCS and pacemaker electrodes are significantly higher than those found in the proximity of the other metallic implants which ranged from 0.04 to 0.69 °C s-1 (129 to 2471 W kg-1). Since the DBS leads that were implanted in the reported human incidents have one-half the electrode surface area of the tested SCS lead, these results imply that tissue heating at rates at least equal to or up to twice as much as those reported here for

  19. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    PubMed

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  20. Impact of crestal and subcrestal implant placement in peri-implant bone: A prospective comparative study

    PubMed Central

    Pellicer-Chover, Hilario; Peñarrocha-Diago, María; Peñarrocha-Oltra, David; Gomar-Vercher, Sonia; Agustín-Panadero, Rubén

    2016-01-01

    Background To assess the influence of the crestal or subcrestal placement of implants upon peri-implant bone loss over 12 months of follow-up. Material and Methods Twenty-six patients with a single hopeless tooth were recruited in the Oral Surgery Unit (Valencia University, Valencia, Spain). The patients were randomized into two treatment groups: group A (implants placed at crestal level) or group B (implants placed at subcrestal level). Control visits were conducted by a trained clinician at the time of implant placement and 12 months after loading. A previously established standard protocol was used to compile general data on all patients (sex and age, implant length and diameter, and brushing frequency). Implant success rate, peri-implant bone loss and the treatment of the exposed implant surface were studied. The level of statistical significance was defined as 5% (α=0.05). Results Twenty-three patients (8 males and 15 females, mean age 49.8±11.6 years, range 28-75 years) were included in the final data analyses, while three were excluded. All the included subjects were nonsmokers with a brushing frequency of up to twice a day in 85.7% of the cases. The 23 implants comprised 10 crestal implants and 13 subcrestal implants. After implant placement, the mean bone position with respect to the implant platform in group A was 0.0 mm versus 2.16±0.88 mm in group B. After 12 months of follow-up, the mean bone positions were -0.06±1.11 mm and 0.95±1.50 mm, respectively - this representing a bone loss of 0.06±1.11 mm in the case of the crestal implants and of 1.22±1.06 mm in the case of the subcrestal implants (p=0.014). Four crestal implants and 5 subcrestal implants presented peri-implant bone levels below the platform, leaving a mean exposed treated surface of 1.13 mm and 0.57 mm, respectively. The implant osseointegration success rate at 12 months was 100% in both groups. Conclusions Within the limitations of this study, bone loss was found to be greater in

  1. Portable punch and die jig

    DOEpatents

    Lewandowski, Edward F.; Anderson, Petrus A.

    1978-01-01

    A portable punch and die jig includes a U-shaped jig of predetermined width having a slot of predetermined width in the base thereof extending completely across the width of the jig adapted to fit over the walls of rectangular tubes and a punch and die assembly disposed in a hole extending through the base of the jig communicating with the slot in the base of the jig for punching a hole in the walls of the rectangular tubes at precisely determined locations.

  2. Breast Implants

    MedlinePlus

    ... sale in the United States: saline-filled and silicone gel-filled. Both types have a silicone outer shell. They vary in size, shell thickness, ... implant them. Provide information on saline-filled and silicone gel-filled breast implants, including data supporting a ...

  3. Dental implants typically help retain peri-implant vertical bone height: evidence-based analysis.

    PubMed

    Greenstein, Gary; Cavallaro, John

    2013-01-01

    The dental literature is assessed regarding the ability of dental implants to maintain vertical bone height after various implant placement scenarios: immediate, delayed, insertion into partially and fully edentate healed ridges, and under overdentures. Studies are also reviewed to determine if bone loss after implant insertion is continuous. Numerous investigations that support the concept that implants preserve bone height are identified. In addition, the data indicate that a minuscule amount of annual bone loss usually persists after implant placement, but it is often clinically imperceptible.

  4. The utility of 3D printing for surgical planning and patient-specific implant design for complex spinal pathologies: case report.

    PubMed

    Mobbs, Ralph J; Coughlan, Marc; Thompson, Robert; Sutterlin, Chester E; Phan, Kevin

    2017-04-01

    OBJECTIVE There has been a recent renewed interest in the use and potential applications of 3D printing in the assistance of surgical planning and the development of personalized prostheses. There have been few reports on the use of 3D printing for implants designed to be used in complex spinal surgery. METHODS The authors report 2 cases in which 3D printing was used for surgical planning as a preoperative mold, and for a custom-designed titanium prosthesis: one patient with a C-1/C-2 chordoma who underwent tumor resection and vertebral reconstruction, and another patient with a custom-designed titanium anterior fusion cage for an unusual congenital spinal deformity. RESULTS In both presented cases, the custom-designed and custom-built implants were easily slotted into position, which facilitated the surgery and shortened the procedure time, avoiding further complex reconstruction such as harvesting rib or fibular grafts and fashioning these grafts intraoperatively to fit the defect. Radiological follow-up for both cases demonstrated successful fusion at 9 and 12 months, respectively. CONCLUSIONS These cases demonstrate the feasibility of the use of 3D modeling and printing to develop personalized prostheses and can ease the difficulty of complex spinal surgery. Possible future directions of research include the combination of 3D-printed implants and biologics, as well as the development of bioceramic composites and custom implants for load-bearing purposes.

  5. Evaluation of an education and follow-up programme for implantable cardioverter defibrillator-implanted patients.

    PubMed

    Cinar, Fatma I; Tosun, Nuran; Kose, Sedat

    2013-09-01

    To determine the experiences, problems and the need for care and education of implantable cardioverter defibrillator-implanted patients and to assess the effects of an education and nurse follow-up programme on their quality of life, anxiety, depression and knowledge level. Although implantable cardioverter defibrillator has become a well-established therapy for people experiencing potentially lethal dysrhythmias, implantable cardioverter defibrillator patients may have physical and psychosocial problems due to the implantation. Applying a planning education and follow-up programme to implantable cardioverter defibrillator-implanted patients may prevent the need for more intensive treatment during the postimplantation period. A mixed methods design that used both qualitative and quantitative data collections and analysis was used for this study. The study was performed in the cardiology department in Turkey between 2009-2010. The data were collected using the 'Semi-Structured Interview Form', 'Form for Assessment of Patients' Knowledge Level about implantable cardioverter defibrillator', 'Spielberger's State-Trait Anxiety Inventory', 'Beck Depression Inventory II' and 'The Short-Form 36 Health Survey'. All forms were completed at the beginning of the study and at six months. The study included 27 patients in the experimental group and 27 patients in the control group. The results showed that the patients were living with various physical and psychosocial problems and insufficient knowledge regarding the implantable cardioverter defibrillator. Education and follow-up programme increased knowledge levels, decreased anxiety and depression scores and improved several subscales of quality of life in the experimental group patients. It was recommended that education and follow-up programme be used for patients scheduled to undergo implantable cardioverter defibrillator implantation, starting before implantation and continuing thereafter, to help patients adapt to a life

  6. Comparison of retention and stability of two implant-retained overdentures based on implant location.

    PubMed

    Scherer, Michael D; McGlumphy, Edwin A; Seghi, Robert R; Campagni, Wayne V

    2014-09-01

    The location of dental implants and the choice of retentive attachments for implant-retained overdentures are selected based on clinician preference, expert opinion, or empirical information. Limited information is available regarding implant position and the effect on the retention and stability of 2-implant mandibular implant overdentures. The purpose of this investigation was to evaluate the effect of implant location on the in vitro retention and stability of a simulated 2-implant-supported overdenture and to examine the differences among different attachment systems. A model that simulates a mandibular edentulous ridge with dental implants in positions that approximate tooth positions, and a cobalt-chromium cast framework attached to a universal testing machine was used to measure the peak load (N) required to disconnect the attachments. Four different types of attachments (Ball/Cap, ERA, Locator, and O-Ring) were used in sequence in various positions on the model to evaluate the effect of implant location on the retention and stability of a simulated 2-implant-retained overdenture. Means were calculated, and differences among the systems, directions, and groups were identified by using a repeated measured ANOVA (α=.05). For differences observed between measurements, the Bonferroni post hoc method at the 5% level of significance was used to determine the location and magnitude of difference. The interactions between the attachment system, direction of force, and implant location were statistically significant (P=.01). The vertical retention and horizontal stability of a simulated overdenture prosthesis increased with the distal implant location up to the second premolar, and the anteroposterior stability increased with distal implant location. The attachment type affected retention and stability differently by location. Ball attachments produced the highest levels of retention and stability, followed by Locator (pink), O-Ring, and ERA (orange). The retention

  7. A 5-year randomized trial to compare 1 or 2 implants for implant overdentures.

    PubMed

    Bryant, S R; Walton, J N; MacEntee, M I

    2015-01-01

    The hypothesis of this 5-y randomized clinical trial was that there would be no significant difference in the satisfaction of edentulous participants with removable complete overdentures attached to 1 or 2 mandibular implants. Secondary aims were to test changes in satisfaction between and within the groups from baseline to 5 y and differences between the groups in implant survival and prosthodontic maintenance over 5 y. Each of the 86 participants (mean age, 67 y) was randomly allocated to receive either 1 implant in the midline (group 1) or 2 implants in the canine areas (group 2) attached to a mandibular overdenture opposing a maxillary complete denture. Satisfaction was self-assessed by participants on a visual analog scale at baseline prior to implants, as well as at 2 mo and 1, 3, and 5 y with implant overdentures, whereas implant survival and prosthodontic maintenance were assessed by clinical examination. After 5 y, 29 participants in group 1 and 33 in group 2 were available, with most dropouts due to death. Satisfaction with the implant denture after 5 y was significantly (P < 0.001) higher than at baseline in both groups and remained with no significant difference (P = 0.32) between the groups. No implants failed in group 1 but 5 failed before loading in 4 participants in group 2. Most participants required maintenance or occasionally denture replacement, and although differences between the groups were not statistically significant, group 1 experienced almost twice as many fractured dentures usually adjacent to the implant attachment. We conclude that there were no significant differences after 5 y in satisfaction or survival of implants with mandibular overdentures retained by 1 implant or 2 implants. Additional research is required to confirm long-term treatment effectiveness of single-implant dentures and the implications of prosthetic maintenance with implant overdentures (ClinicalTrials.gov: NCT02117856). © International & American Associations for

  8. Improvement of Die Corner Filling in Box-shape Stepped Tubes Hydroforming

    NASA Astrophysics Data System (ADS)

    Hosseini-Farrash, S. H.; Elyasi, M.; Bakhshi-Jooybari, M.; Gorji, A.

    2011-01-01

    A new die design to improve the die corner filling in the hydroforming of square-sectional stepped tubes is presented. The proposed die-set contains two additional bushes, compared to the common tube hydroforming dies. First, the tube is placed into the die, filled with liquid, and sealed with the punches. Then, by increasing the internal pressure, the tube is bulged and contacts the die walls (bulging stage). By maintaining the internal pressure, the two upper and lower bushes move until the die cavity is filled completely (calibration stage). The proposed die was simulated and the results show that sharp corners of the part and relatively complete filling of the die cavity can be obtained by using this die set. In order to verify the results, some experiments have been carried out. The experimental results verified the results obtained from the simulations. The thickness distribution of the part is also investigated and it is shown that fairly uniform thickness distribution can be obtained by using the proposed die set.

  9. Tubing erosion of an inflatable penile prosthesis long after implantation.

    PubMed

    Morales, Alvaro

    2014-06-01

    Erosion through skin of connecting tubing of an inflatable penile prosthesis (IPP) has not been previously reported. The aim of this study was to present a case of tubing erosion, review the pertinent literature, and discuss the possible causes and management options, including preservation of the device and its components. A 42-year-old male failing to respond to medical treatment for erectile dysfunction underwent insertion of an AMS 700 IPP in 1986. Six years later, a revision was necessary because of a leak in the right cylinder and 4 years after, the pump was replaced. Fourteen years after the original implant, he presented with a portion of the tube connecting the pump to the right cylinder eroding through the skin. There was no infection. The skin area involved was resected and the original pump and tubing were buried in a new scrotal pocket after thorough irrigation. The IPP remained in place, allowing vaginal penetration and without infection for another 11 years. Three years later, it was de-functionalized, converted into a fixed volume device. It eventually was replaced 25 years after originally implanted with a semirigid prosthesis because it did not provide sufficient rigidity and because of concerns about the presence of "screws" detected during pelvic imaging. Mechanical failures in the early IPP models, as illustrated in this case, were expected. However, the long survival of the device is remarkable. Erosion of the connecting tubing through the skin is unique and, under exceptional circumstances, may be managed conservatively without replacing components of the IPP. Clinicians unfamiliar with procedures involving inflatable devices need to be aware of "foreign bodies" visible in radiological examinations in men who have had revisions of an IPP. Morales A. Tubing erosion of an inflatable penile prosthesis long after implantation. Sex Med 2014;2:103-106.

  10. An economic evaluation of maxillary implant overdentures based on six vs. four implants.

    PubMed

    Listl, Stefan; Fischer, Leonhard; Giannakopoulos, Nikolaos Nikitas

    2014-08-18

    The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients' denture satisfaction, the respective cost-effectiveness threshold varies substantially. The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes.

  11. An economic evaluation of maxillary implant overdentures based on six vs. four implants

    PubMed Central

    2014-01-01

    Background The purpose of the present study was to assess the value for money achieved by bar-retained implant overdentures based on six implants compared with four implants as treatment alternatives for the edentulous maxilla. Methods A Markov decision tree model was constructed and populated with parameter estimates for implant and denture failure as well as patient-centred health outcomes as available from recent literature. The decision scenario was modelled within a ten year time horizon and relied on cost reimbursement regulations of the German health care system. The cost-effectiveness threshold was identified above which the six-implant solution is preferable over the four-implant solution. Uncertainties regarding input parameters were incorporated via one-way and probabilistic sensitivity analysis based on Monte-Carlo simulation. Results Within a base case scenario of average treatment complexity, the cost-effectiveness threshold was identified to be 17,564 € per year of denture satisfaction gained above of which the alternative with six implants is preferable over treatment including four implants. Sensitivity analysis yielded that, depending on the specification of model input parameters such as patients’ denture satisfaction, the respective cost-effectiveness threshold varies substantially. Conclusions The results of the present study suggest that bar-retained maxillary overdentures based on six implants provide better patient satisfaction than bar-retained overdentures based on four implants but are considerably more expensive. Final judgements about value for money require more comprehensive clinical evidence including patient-centred health outcomes. PMID:25135370

  12. Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures.

    PubMed

    Bernhart, Gunda; Koob, Andreas; Schmitter, Marc; Gabbert, Olaf; Stober, Thomas; Rammelsberg, Peter

    2012-08-01

    The objective of this retrospective study was to compare biological and technical complications of implant-supported and tooth-implant-supported double crown-retained dentures (DCRDs) with those of tooth-supported DCRDs. Sixty-three DCRDs were monitored. One study group included 16 prostheses with a combination of implants and natural teeth as double crowns (ti group), whereas in the second study group, 19 dentures were retained exclusively on implants (ii group); a third study group with 28 exclusively tooth-supported dentures served as controls (tt group). Tooth loss, implant failure, and technical complications (loss of retention of primary crown, abutment screw loosening, loss of facing, fracture of resin denture teeth and fracture of saddle resin) were analysed. During the observation period of 24 months, no implants or teeth were lost in the ti group and three technical complications were recorded. In the ii group, two implants were lost, two cases of peri-implantitis occurred and four technical complications were observed. In the tt group, two cases of tooth loss and seven technical complications were observed. At the time of the last examination, all prostheses of the ti group and the ii group were functional. Patients of these two study groups reported high satisfaction with both function and aesthetics with no significant difference between the two groups. Treatment with DCRDs showed comparable results in the three study groups. The 2-year results indicate that double crowns can be recommended for implant and combined tooth-implant-retained dentures.

  13. Radiological dispersion devices: are we prepared?

    PubMed

    Sohier, Alain; Hardeman, Frank

    2006-01-01

    Already before the events of September 11th 2001 concern was raised about the spread of orphan sources and their potential use in Radiological Dispersion Devices by terrorist groups. Although most of the simulated scenarios foresee a rather limited direct health impact on the population, the affected region would suffer from the indirect consequences such as social disruption, cleanup requirements and economic costs. The nature of such a radiological attack would anyway be different compared to conventional radiological accidents, basically because it can happen anywhere at any time. Part of the response resides in a general preparedness scheme incorporating attacks with Radiological Dispersion Devices. Training of different potential intervention teams is essential. The response would consist of a prioritised list of actions adapted to the circumstances. As the psychosocial dimension of the crisis could be worse than the purely radiological one, an adapted communication strategy with the public aspect would be a key issue.

  14. [Researches on biomechanics of micro-implant-bone interface and optimum design of micro implant's neck].

    PubMed

    Deng, Feng; Zhang, Lei; Zhang, Yi; Song, Jin-lin; Fan, Yuboa

    2007-07-01

    To compare and analyze the stress distribution at the micro-implant-bone interface based on the different micro-implant-bone conditioned under orthodontic load, and to optimize the design of micro implant's neck. An adult skull with all tooth was scanned by spiral CT, and the data were imported into computer for three-dimensional reconstruction with software Mimics 9.0. The three dimensional finite element models of three micro-implant-bone interfaces(initial stability, full osseointegration and fibrous integration) were analyzed by finite element analysis software ABAQUS6.5. The primary stress distributions of different micro-implant-bone conditions were evaluated when 2N force was loaded. Then the diameter less than 1.5 mm of the micro implant's neck was added with 0.2 mm, to compare the stress distribution of the modified micro-implant-bone interface with traditional type. The stress mostly concentrated on the neck of micro implant and the full osseointegration interface in all models showed the lowest strain level. Compared with the traditional type, the increasing diameter neck of the micro implant obviously decreased the stress level in all the three conditions. The micro-implant-bone interface and the diameter of micro implant's neck both are the important influence factors to the stress distribution of micro implant.

  15. Implant Mandibular Overdentures Retained by Immediately Loaded Implants: A 1-Year Randomized Trial Comparing the Clinical and Radiographic Outcomes Between Mini Dental Implants and Standard-Sized Implants.

    PubMed

    Zygogiannis, Kostas; Aartman, Irene Ha; Parsa, Azin; Tahmaseb, Ali; Wismeijer, Daniel

    The aim of this 1-year randomized trial was to evaluate and compare the clinical and radiographic performance of four immediately loaded mini dental implants (MDIs) and two immediately loaded standard-sized tissue-level (STL) implants, placed in the interforaminal region of the mandible and used to retain mandibular overdentures (IODs) in completely edentulous patients. A total of 50 completely edentulous patients wearing conventional maxillary dentures and complaining about insufficient retention of their mandibular dentures were divided into two groups; 25 patients received four MDIs and 25 patients received two STL implants. The marginal bone loss (MBL) at the mesial and distal sides of each implant was assessed by means of standardized intraoral radiographs after a period of 1 year. Implant success and survival rates were also calculated. Immediate loading was possible for all patients in the first group. In the second group, an immediate loading protocol could not be applied for 10 patients. These patients were treated with a delayed loading protocol. A mean MBL of 0.42 ± 0.56 mm for the MDIs and 0.54 ± 0.49 mm for the immediately loaded STL implants was recorded at the end of the evaluation period. There was no statistically significant difference between the MDIs and the immediately loaded STL implants. Two MDIs failed, resulting in a survival rate of 98%. The success rate was 91%. For the immediately loaded conventional implants, the survival rate was 100% and the success rate 96.7% after 1 year of function. However, in 10 patients, the immediate loading protocol could not be followed. Considering the limitations of this short-term clinical study, immediate loading of four unsplinted MDIs or two splinted STL implants to retain mandibular overdentures seems to be a feasible treatment option. The marginal bone level changes around the MDIs were well within the clinically acceptable range.

  16. The Role of the World Health Organization's International Classification of Functioning, Health and Disability in Models of Infant Cochlear Implant Management

    PubMed Central

    Psarros, Colleen; Love, Sarah

    2016-01-01

    Newborn hearing screening has led to the early diagnosis of hearing loss in neonates and early device fitting is common, based primarily on electrophysiologic and radiologic information, with some supplementary behavioral measures. Such early fitting of hearing devices, in particular cochlear implants (CIs), has been beneficial to the majority of children implanted under the age of 12 months who meet the cochlear implant candidacy criteria. Comorbidities are common in children with hearing loss, although they may not be evident in neonates and may not emerge until later in infants. Evidence suggests that the child's outcomes are strongly influenced by a range of environmental factors including emotional and social support from the immediate and extended family. Consequently, such factors are important in service planning and service delivery for babies and children receiving CIs. The World Health Organization's International Classification of Functioning, Health and Disability (ICF) can provide a framework to facilitate the holistic management of pediatric cochlear implant recipients. The ICF also can be used to map the progress of recipients over time to highlight emerging issues that require intervention. This article will discuss our preliminary use of the ICF to establish clinical practice; develop advocacy skills among clients and their families; identify eligibility for services such as support in educational settings; enable access to modes of service delivery such as telepractice; provide a conceptual framework for policy and program development for pediatric cochlear implant recipients (i.e., in both disability and health services); and, most importantly, establish a clear pathway for the longitudinal management of the cochlear implant in a child's future. It is anticipated that this model will be applied to other populations receiving cochlear implants through our program. PMID:27489404

  17. Randomized study on the effect of single-implant versus two-implant retained overdentures on implant loss and muscle activity: a 12-month follow-up report.

    PubMed

    Alqutaibi, A Y; Kaddah, A F; Farouk, M

    2017-06-01

    The objective was to evaluate and compare single- and two-implant retained overdentures for the rehabilitation of the edentulous mandible. Fifty-six edentulous subjects were eligible for inclusion. Using a random sampling system, a single implant or two implants were placed in the mandible. After 3 months, locator attachments were connected to the implants and the denture delivered with the retentive components incorporated in the denture base. Implant failure and muscle activity were evaluated at the 3-, 6-, and 12-month follow-up examinations. The study sample comprised 56 patients (32 male, 24 female), with a mean age of 58.2 years. A total of 84 implants were placed (28 in the single-implant group and 56 in the two-implant group). All patients completed the 12 months of follow-up. No significant differences were found between subjects in the two groups with respect to implant failure. With regard to improvements in muscle activity, the two-implant group showed statistically significant but perhaps not clinically important differences. Single-implant mandibular overdentures may be suggested as an alternative treatment modality for the rehabilitation of edentulous patients who cannot afford the cost of a two-implant overdenture. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. 21 CFR 892.1830 - Radiologic patient cradle.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiologic patient cradle. 892.1830 Section 892.1830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1830 Radiologic patient cradle. (a...

  19. Infection rates of rifampin/gentamicin-coated Titan Coloplast penile implants. Comparison with Inhibizone-impregnated AMS penile implants.

    PubMed

    Dhabuwala, Chirpriya; Sheth, Sheila; Zamzow, Brent

    2011-01-01

    It is a common practice to soak Titan(®) Coloplast penile implants in antibiotic solution prior to implantation. Experience with Inhibizone impregnation suggests that rifampin coating significantly reduces infection rates of penile implant surgery. In this article we describe the results of coating Titan Coloplast penile implants with rifampin/gentamicin solution. To compare infection rates of Titan(®) Coloplast penile implants coated with vancomycin/gentamycin, rifampin/gentamicin, and Inhibizone-impregnated American Medical Systems (AMS) penile implants. Chart review was done for all Mentor/Coloplast and AMS implant surgeries performed at our center between the dates January 1, 2002 and February 8, 2010. Infection rates for Titan(®) Coloplast penile implants coated with vancomycin/gentamycin, rifampin/gentamicin, and Inhibizone-impregnated (AMS) penile implants were compared. Infection rates for penile implants coated with different antibiotics. Infection rates for Titan(®) Coloplast penile implants coated with vancomycin/gentamycin and Inhibizone-impregnated (AMS) penile implants was 4.4% and 1.3%, respectively (P = 0.05). None of the rifampin/gentamicin-coated Titan(®) Coloplast penile implants have developed infection. Rifampin is the common antibiotic both in rifampin/gentamicin-coated Coloplast implants and Inhibizone(®) . The infection rate in this combined rifampin/gentamicin-coated Titan Coloplast implants and Inhibizone-coated AMS implants group was 0.63% (P = 0.03). Both rifampin/gentamicin-coated Titan(®) Coloplast penile implants and Inhibizone-impregnated (AMS) penile implants appear to have lower infection rates compared with vancomycin/gentamycin-coated Titan(®) Coloplast penile implants The present study does not suggest superiority of rifampin/gentamicin-coated Titan(®) Coloplast penile implants or Inhibizone-impregnated (AMS) penile implants but we strongly suggest that all Titan(®) Coloplast penile implants should be coated with

  20. Optimization of Composition and Heat Treating of Die Steels for Extended Lifetime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    David Schwam; John F. Wallace; Quanyou Zhou

    2002-01-30

    An ''average'' die casting die costs fifty thousand dollars. A die used in making die cast aluminum engine blocks can cost well over one million dollars. These costs provide a strong incentive for extension of die life. While vacuum quenched Premium Grade H13 dies have become the most widely used in the United States, tool makers and die casters are constantly searching for new steels and heat treating procedures to extend die life. This project was undertaken to investigate the effects of composition and heat treating on die life and optimize these parameters.

  1. Influence Of Implantation Age On School-Age Language Performance In Pediatric Cochlear Implant Users

    PubMed Central

    Tobey, Emily A.; Thal, Donna; Niparko, John K.; Eisenberg, Laurie S.; Quittner, Alexandra L.; Wang, Nae-Yuh

    2013-01-01

    Objective This study examined specific spoken language abilities of 160 children with severe-to-profound sensorineural hearing loss followed prospectively 4, 5, or 6 years after cochlear implantation. Study sample Ninety-eight children received implants before 2.5 years, and 62 children received implants between 2.5 and 5 years of age. Design Language was assessed using four subtests of the Comprehensive Assessment of Spoken Language (CASL). Standard scores were evaluated by contrasting age of implantation and follow-up test time. Results Children implanted under 2.5 years of age achieved higher standard scores than children with older ages of implantation for expressive vocabulary, expressive syntax, and pragmatic judgments. However, in both groups, some children performed more than two standard deviations below the standardization group mean, while some scored at or well above the mean. Conclusions Younger ages of implantation are associated with higher levels of performance, while later ages of implantation are associated with higher probabilities of continued language delays, particularly within subdomains of grammar and pragmatics. Longitudinal data from this cohort study demonstrate that after 6 years of implant experience, there is large variability in language outcomes associated with modifiers of rates of language learning that differ as children with implants age. PMID:23448124

  2. Influence of Palatal Coverage and Implant Distribution on Denture Strain in Maxillary Implant Overdentures.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Tomita, Akiko; Mizuno, Yoko; Maeda, Yoshinobu

    2016-01-01

    As maxillary implant overdentures are being increasingly used in clinical practice, prosthodontic complications related to these dentures are also reported more often. The purpose of this study was to examine the influence of palatal coverage and implant distribution on the shear strain of maxillary implant overdentures. A maxillary edentulous model with implants inserted in the anterior, premolar, and molar areas was fabricated. Two kinds of experimental overdentures, with and without palatal coverage, were also fabricated, and two strain gauges were attached at the midline of the labial and palatal sides. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the shear strain in each denture was compared by analysis of variance (P = .05). In all situations, the shear strain in palateless dentures was significantly higher than in dentures with palate on both sides (P < .05). In dentures with palate, the shear strain was lower when anterior implants were present. Palateless maxillary implant overdentures exhibited much higher strain than overdentures with palate regardless of the implant distribution; this may cause more prosthodontic and implant complications. The most favorable configuration to prevent complications in maxillary implant overdentures was palatal coverage that was supported by more than four widely distributed implants.

  3. Comparison of peri-implant bone formation around injection-molded and machined surface zirconia implants in rabbit tibiae

    PubMed Central

    Kim, Hong-Kyun; Woo, Kyung mi; Shon, Won-Jun; Ahn, Jin-Soo; Cha, Seunghee; Park, Young-Seok

    2017-01-01

    The aim of this study was to compare osseointegration and surface characteristics of zirconia implants made by the powder injection molding (PIM) technique and made by the conventional milling procedure in rabbit tibiae. Surface characteristics of 2 types of implant were evaluated. Sixteeen rabbits received 2 types of external hex implants with similar geometry, machined zirconia implants and PIM zirconia implants, in the tibiae. Removal torque tests and histomorphometric analyses were performed. The roughness of PIM zirconia implants was higher than that of machined zirconia implants. The PIM zirconia implants exhibited significantly higher bone-implant contact and removal torque values than the machined zirconia implants (P < 0.001). The osseointegration of the PIM zirconia implant is promising, and PIM, using the roughened mold etching technique, can produce substantially rough surfaces on zirconia implants. PMID:26235717

  4. Silicone Gel-Filled Breast Implants

    MedlinePlus

    ... and Medical Procedures Implants and Prosthetics Breast Implants Silicone Gel-Filled Breast Implants Share Tweet Linkedin Pin ... sharing options Linkedin Pin it Email Print Description: Silicone gel-filled breast implants have a silicone outer ...

  5. Surface and mechanical analysis of explanted Poly Implant Prosthèse silicone breast implants.

    PubMed

    Yildirimer, L; Seifalian, A M; Butler, P E

    2013-05-01

    The recent events surrounding Poly Implant Prosthèse (PIP) breast implants have renewed the debate about the safety profile of silicone implants. The intentional use of industrial-grade instead of certified medical-grade silicone is thought to be responsible for reportedly higher frequencies of implant rupture in vivo. The differences in mechanical and viscoelastic properties between PIP and medical-grade silicone implant shells were investigated. Surface characterization of shells and gels was carried out to determine structural changes occurring after implantation. Breast implants were obtained from women at the Royal Free Hospital (London, UK). PIP implants were compared with medical-grade control silicone implants. Tensile strength, tear resistance and elongation at break were assessed using a tensile tester. Surfaces were analysed using attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy. Spearman correlation analyses and Kruskal-Wallis one-way statistical tests were performed for mechanical data. There were 18 PIP and four medical-grade silicone implants. PIP silicone shells had significantly weaker mechanical strength than control shells (P < 0·009). There were negative correlations between mechanical properties of PIP shells and implantation times, indicative of deterioration of PIP shells over time in vivo (r(s) = -0·75, P = 0·009 for tensile strength; r(s) = -0·76, P = 0·001 for maximal strain). Comparison of ATR-FTIR spectra of PIP and control silicones demonstrated changes in material characteristics during the period of implantation suggestive of time-dependent bond breakage and degradation of the material. This study demonstrated an increased weakness of PIP shells with time and therefore supports the argument for prophylactic removal of PIP breast implants. © 2013 British Journal of Surgery Society Ltd. Published by John Wiley & Sons Ltd.

  6. Information extraction from multi-institutional radiology reports.

    PubMed

    Hassanpour, Saeed; Langlotz, Curtis P

    2016-01-01

    The radiology report is the most important source of clinical imaging information. It documents critical information about the patient's health and the radiologist's interpretation of medical findings. It also communicates information to the referring physicians and records that information for future clinical and research use. Although efforts to structure some radiology report information through predefined templates are beginning to bear fruit, a large portion of radiology report information is entered in free text. The free text format is a major obstacle for rapid extraction and subsequent use of information by clinicians, researchers, and healthcare information systems. This difficulty is due to the ambiguity and subtlety of natural language, complexity of described images, and variations among different radiologists and healthcare organizations. As a result, radiology reports are used only once by the clinician who ordered the study and rarely are used again for research and data mining. In this work, machine learning techniques and a large multi-institutional radiology report repository are used to extract the semantics of the radiology report and overcome the barriers to the re-use of radiology report information in clinical research and other healthcare applications. We describe a machine learning system to annotate radiology reports and extract report contents according to an information model. This information model covers the majority of clinically significant contents in radiology reports and is applicable to a wide variety of radiology study types. Our automated approach uses discriminative sequence classifiers for named-entity recognition to extract and organize clinically significant terms and phrases consistent with the information model. We evaluated our information extraction system on 150 radiology reports from three major healthcare organizations and compared its results to a commonly used non-machine learning information extraction method. We

  7. Radiological Technology. Secondary Curriculum Guide.

    ERIC Educational Resources Information Center

    Simpson, Bruce; And Others

    This curriculum guide was designed for use in postsecondary radiological technology education programs in Georgia. Its purpose is to provide for the development of entry level skills in radiological technology in the areas of knowledge, theoretical structure, tool usage, diagnostic ability, related supportive skills, and occupational survival…

  8. Influence of prosthesis design and implantation technique on implant stresses after cementless revision THR

    PubMed Central

    2011-01-01

    Background Femoral offset influences the forces at the hip and the implant stresses after revision THR. For extended bone defects, these forces may cause considerable bending moments within the implant, possibly leading to implant failure. This study investigates the influences of femoral anteversion and offset on stresses in the Wagner SL revision stem implant under varying extents of bone defect conditions. Methods Wagner SL revision stems with standard (34 mm) and increased offset (44 mm) were virtually implanted in a model femur with bone defects of variable extent (Paprosky I to IIIb). Variations in surgical technique were simulated by implanting the stems each at 4° or 14° of anteversion. Muscle and joint contact forces were applied to the reconstruction and implant stresses were determined using finite element analyses. Results Whilst increasing the implant's offset by 10 mm led to increased implant stresses (16.7% in peak tensile stresses), altering anteversion played a lesser role (5%). Generally, larger stresses were observed with reduced bone support: implant stresses increased by as much as 59% for a type IIIb defect. With increased offset, the maximum tensile stress was 225 MPa. Conclusion Although increased stresses were observed within the stem with larger offset and increased anteversion, these findings indicate that restoration of offset, key to restoring joint function, is unlikely to result in excessive implant stresses under routine activities if appropriate fixation can be achieved. PMID:21569522

  9. Novel implant design improves implant survival in multirooted extraction sites: a preclinical pilot study.

    PubMed

    Sivan-Gildor, Adi; Machtei, Eli E; Gabay, Eran; Frankenthal, Shai; Levin, Liran; Suzuki, Marcelo; Coelho, Paulo G; Zigdon-Giladi, Hadar

    2014-10-01

    The primary aim is to evaluate clinical, radiographic, and histologic parameters of novel implants with "three roots" design that were inserted into fresh multirooted extraction sockets. A secondary aim is to compare this new implant to standard root-form dental implants. Immediate implantation of novel or standard design 6 × 6-mm implants was performed bilaterally into multirooted sockets in mandibles of mini-pigs. Twelve weeks later, clinical, radiographic, stability, histomorphometric, and microcomputed tomography (micro-CT) analyses were performed. Survival rates were significantly higher in the test implants compared with control (92.8% versus 33.3%, respectively; P <0.001). Bone loss was greater in the control compared with the test by sounding (mean 3.42 ± 0.68 versus 1.96 ± 0.34 mm) and radiography (mean 3.35 ± 0.62 versus 2.27 ± 0.33 mm). Histologic and micro-CT analyses demonstrated bone fill in the inner part of the test implants. Moreover, bone-to-implant contact was higher in the test implants (55.50% ± 3.68% versus 42.47% ± 9.89%). Contrary to the clinical, radiographic, and histomorphometric results, resonance frequency analysis measurements were greater in the control group (77.74 ± 3.21 implant stability quotient [ISQ]) compared with the test group (31.09 ± 0.28 ISQ), P = 0.008. The novel design implants resulted in significantly greater survival rate in multirooted extraction sites. Further studies will be required to validate these findings.

  10. Updated secondary implant stability data of two dental implant systems. A retrospective cohort study

    PubMed Central

    Verleye, Gino; Mavreas, Dimitrios; Vande-Vannet, Bart

    2017-01-01

    Background At present, updated secondary implant stability data generated by actual versions of resonance frequency analysis (RFA) and mobility measurement (MM) electronic devices of 2 different implant systems with actual manufactured surfaces seem to lack and/or are incomplete. Material and Methods Secondary implant stability data based on both RFA and MM measurements were collected and analyzed from 44 formerly treated patients (24 f, 20 m) that received either Ankylos Cellplus (Ø3.5mm) (A) (n=36) or Straumann regular neck SLA tissue level (Ø4.1mm) (S) (n=37) implants in posterior positions of both jawbones (total number= 72). These results were interpretated in view of formerly published data. Results Estimated RFA outcomes (mean±SD) for A implants were of 81.23 (±0.65) (LP) - 76.15 (±1.57) (UP) isq; for S implants 76.15 (±1.48) (LP) - 73.88 (±2.34) (UP) isq. Estimated MM outcomes for A implants were (-4.0) (±0.23) (LP) - (-3.2) (±0.33) (UP) ptv; for S implants (-5.15) (±0.39) (LP) - (-4.4) (±0.84) (UP) ptv. According to GEE statistical modelling, implant type and – position seems to influence the outcome variables (p<0.05), gender and implant length did not (p >0.05). Conclusions Secondary implant stability values, recorded with current RFA and MM devices, of A Cellplus implants are provided for the first time. A difference of 14.7-9.7 isq values was noted for CellPlus versus TPS S implants recorded with a cabled RFA device. This study supports the assumption that RFA outcomes generated with first generation RFA devices are different from those obtained with current RFA devices, meaning that its use in reviews need caution and correction. Key words:Secondary implant stability, resonance frequency analysis, Periotest, Osstell Mentor, Straumann, Ankylos, CellPlus, SLA. PMID:29075415

  11. Dying in the age of choice.

    PubMed

    Black, Kathy; Csikai, Ellen L

    2015-01-01

    Due to the unprecedented increase in the United States aging demographics, many more people are living longer and reaching older ages than ever before. However, a longer life is not necessarily a better life, as the vast majority will face a period of prolonged deteriorating health prior to death. Although notable efforts have been underway that are designed to improve the end-of-life experience, increasing numbers of individuals express a desire and/or act upon an intent to end their lives precipitously. Though still limited, the options to actively participate in their own deaths are growing. Requests for a hastened death can occur among people of all ages and includes those with advanced illness as well as others wanting to die due to unbearable suffering. This article provides an overview of the ongoing discourse about the experience of dying faced by many older adults, including aspects frequently associated with "a good death." The limitations of established practices which seek to provide a "better" dying experience are identified followed by discussion of the growing availability of alternative options. Reflective considerations are presented to guide practice vis-à-vis the changing landscape surrounding options in dying.

  12. Prevalence and Prognostic Significance of Right Ventricular Systolic Dysfunction in Patients Undergoing Transcatheter Aortic Valve Implantation.

    PubMed

    Lindsay, Alistair C; Harron, Katie; Jabbour, Richard J; Kanyal, Ritesh; Snow, Thomas M; Sawhney, Paramvir; Alpendurada, Francisco; Roughton, Michael; Pennell, Dudley J; Duncan, Alison; Di Mario, Carlo; Davies, Simon W; Mohiaddin, Raad H; Moat, Neil E

    2016-07-01

    Cardiovascular magnetic resonance (CMR) can provide important structural information in patients undergoing transcatheter aortic valve implantation. Although CMR is considered the standard of reference for measuring ventricular volumes and mass, the relationship between CMR findings of right ventricular (RV) function and outcomes after transcatheter aortic valve implantation has not previously been reported. A total of 190 patients underwent 1.5 Tesla CMR before transcatheter aortic valve implantation. Steady-state free precession sequences were used for aortic valve planimetry and to assess ventricular volumes and mass. Semiautomated image analysis was performed by 2 specialist reviewers blinded to patient treatment. Patient follow-up was obtained from the Office of National Statistics mortality database. The median age was 81.0 (interquartile range, 74.9-85.5) years; 50.0% were women. Impaired RV function (RV ejection fraction ≤50%) was present in 45 (23.7%) patients. Patients with RV dysfunction had poorer left ventricular ejection fractions (42% versus 69%), higher indexed left ventricular end-systolic volumes (96 versus 40 mL), and greater indexed left ventricular mass (101 versus 85 g/m(2); P<0.01 for all) than those with normal RV function. Median follow-up was 850 days; 21 of 45 (46.7%) patients with RV dysfunction died, compared with 43 of 145 (29.7%) patients with normal RV function (P=0.035). After adjustment for significant baseline variables, both RV ejection fraction ≤50% (hazard ratio, 2.12; P=0.017) and indexed aortic valve area (hazard ratio, 4.16; P=0.025) were independently associated with survival. RV function, measured on preprocedural CMR, is an independent predictor of mortality after transcatheter aortic valve implantation. CMR assessment of RV function may be important in the risk stratification of patients undergoing transcatheter aortic valve implantation. © 2016 American Heart Association, Inc.

  13. Finite element analysis of different loading conditions for implant-supported overdentures supported by conventional or mini implants.

    PubMed

    Solberg, K; Heinemann, F; Pellikaan, P; Keilig, L; Stark, H; Bourauel, C; Hasan, I

    2017-05-01

    The effect of implants' number on overdenture stability and stress distribution in edentulous mandible, implants and overdenture was numerically investigated for implant-supported overdentures. Three models were constructed. Overdentures were connected to implants by means of ball head abutments and rubber ring. In model 1, the overdenture was retained by two conventional implants; in model 2, by four conventional implants; and in model 3, by five mini implants. The overdenture was subjected to a symmetrical load at an angle of 20 degrees to the overdenture at the canine regions and vertically at the first molars. Four different loading conditions with two total forces (120, 300 N) were considered for the numerical analysis. The overdenture displacement was about 2.2 times higher when five mini implants were used rather than four conventional implants. The lowest stress in bone bed was observed with four conventional implants. Stresses in bone were reduced by 61% in model 2 and by 6% in model 3 in comparison to model 1. The highest stress was observed with five mini implants. Stresses in implants were reduced by 76% in model 2 and 89% increased in model 3 compared to model 1. The highest implant displacement was observed with five mini implants. Implant displacements were reduced by 29% in model 2, and increased by 273% in model 3 compared to model 1. Conventional implants proved better stability for overdenture than mini implants. Regardless the type and number of implants, the stress within the bone and implants are below the critical limits.

  14. "Not all breast implants are equal: a 13-year review of implant longevity and reasons for explantation".

    PubMed

    Van Slyke, Aaron C; Carr, Michael; Carr, Nicholas J

    2018-06-04

    Augmentation mammoplasty is the most common aesthetic procedure. Textured implants control implant position and have improved capsular contracture rates; however, the impact of texturing on longevity and clinical findings at explantation is unclear. All cases of explantation between January 2005 - April 2017 from an aesthetic practice were reviewed retrospectively. Patient demographics, implant characteristics, time-to-explantation, and clinical presentation and intraoperative findings at explantation were analyzed. 539 breast implants were explanted during the study period: 249 saline, 147 smooth gel, 123 Biocell, and 20 other nonaggressively textured breast implants. Average time from placement to explantation was 7.5 years, 5.6 years, 4.9 years, and 4.0 years for saline, other textured, smooth gel, and Biocell implants, respectively (p-value = 3.25e-08). The percentage of implants removed associated with implant performance failure was 50.3%, 57.5%, 75.0%, and 85.4% for smooth gel, saline, other textured, and Biocell implants, respectively (p-value = 7.25e-09). 21.1% of Biocell implants versus 1.5% of all other implants presented with pain (p-value = 2.71e-15). 45 Biocell implants had double capsules; this phenomenon was not observed with any other implant type (p-value = 5.85e-37). Seven Biocell implants had late seromas, compared to three late seromas with any other implant type (p-value = 0.0013). Here, we provide evidence that Biocell implants have the shortest time-to-explantation and the highest proportion of implants associated with implant performance failure. This information should complement the informed consent process when selecting an appropriate implant.

  15. Effect of Healing Time on Bone-Implant Contact of Orthodontic Micro-Implants: A Histologic Study

    PubMed Central

    Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed

    2014-01-01

    Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability. PMID:25006463

  16. Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

    PubMed

    Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed

    2014-01-01

    Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability.

  17. The effect of varying implant position in immediately loaded implant-supported mandibular overdentures.

    PubMed

    Shaarawy, Mohammed A; Aboelross, Ehab M

    2013-06-01

    This study was carried out to evaluate the effect of varying implant position in immediately loaded implant-supported mandibular overdentures on peri-implant bone density, muscle activity, and patient satisfaction. Fourteen completely edentulous patients were selected for the study. After complete denture construction, patients were divided into 2 equal groups. Four dental implants were installed bilaterally in the interforaminal region in the first group, while in the second group, 4 dental implants were inserted bilaterally: 2 in the interforaminal region and 2 in the first molar area. Immediately after suturing, telescopic abutments were screwed to the implants, and the retaining caps were picked up into the fitting surface of the lower denture, which was delivered to the patient. Patients were recalled for radiographic bone density evaluation just after denture delivery and then at 3, 6, and 12 months thereafter. Muscle activities of masseter and temporalis muscles as well as patient satisfaction were also evaluated. The results of the study showed a high success rate approximating 98.2% of the immediately loaded implants. The electromyographic (EMG) records of both muscles in group 1 were significantly higher during chewing hard food after 3 months compared with group 2 (P < .05). Bone density changes were comparable in the 2 groups except at the end of the follow-up period, when group 2 showed a significant increase in peri-implant bone density values of the posteriorly placed implants compared with group 1 (P < .05). From the results of this study, it may be concluded that wide distribution of immediately loaded implants used for supporting mandibular overdentures through posterior placement beyond the interforaminal area results in a favorable response in terms of increased peri-implant bone density as well as decreased EMG activity of masseter and temporalis muscles.

  18. Integrated Fellowship in Vascular Surgery and Intervention Radiology

    PubMed Central

    Messina, Louis M.; Schneider, Darren B.; Chuter, Timothy A. M.; Reilly, Linda M.; Kerlan, Robert K.; LaBerge, Jeane M.; Wilson, Mark W.; Ring, Ernest J.; Gordon, Roy L.

    2002-01-01

    Objective To evaluate an integrated fellowship in vascular surgery and interventional radiology initiated to train vascular surgeons in endovascular techniques and to train radiology fellows in clinical aspects of vascular diseases. Summary Background Data The rapid evolution of endovascular techniques for the treatment of vascular diseases requires that vascular surgeons develop proficiency in these techniques and that interventional radiologists develop proficiency in the clinical evaluation and management of patients who are best treated with endovascular techniques. In response to this need the authors initiated an integrated fellowship in vascular surgery and interventional radiology and now report their interim results. Methods Since 1999 vascular fellows and radiology fellows performed an identical year-long fellowship in interventional radiology. During the fellowship, vascular surgery and radiology fellows perform both vascular and nonvascular interventional procedures. Both vascular surgery and radiology-based fellows spend one quarter of the year on the vascular service performing endovascular aortic aneurysm repairs and acquiring clinical experience in the vascular surgery inpatient and outpatient services. Vascular surgery fellows then complete an additional year-long fellowship in vascular surgery. To evaluate the type and number of interventional radiology procedures, the authors analyzed records of cases performed by all interventional radiology and vascular surgery fellows from a prospectively maintained database. The attitudes of vascular surgery and interventional radiology faculty and fellows toward the integrated fellowship were surveyed using a formal questionnaire. Results During the fellowship each fellow performed an average of 1,201 procedures, including 808 vascular procedures (236 diagnostic angiograms, 70 arterial interventions, 59 diagnostic venograms, 475 venous interventions, and 43 hemodialysis graft interventions) and 393

  19. Language acquisition after cochlear implantation of congenitally deaf children: Effect of age at implantation

    NASA Astrophysics Data System (ADS)

    Svirsky, Mario; Holt, Rachael

    2005-04-01

    Evidence shows that early implantation of congenitally deaf children is beneficial. However, infants as young as 6 months of age have started to receive cochlear implants (CIs) in the USA. Such early implantation may be associated with higher risks, including anesthetic risk as well as the increased possibility of a false positive in the diagnosis of profound deafness. On the other hand, delaying implantation may be associated with the risk of missing windows of opportunity or sensitive periods for the development of communication skills. In this study, speech perception and language skills in children who received CIs in the first, second, third, or fourth year of life were compared. Participants were tested at regular 6-month intervals after implantation. The effects of several potential confounds were considered. In general, children implanted earlier outperformed those implanted later, with one exception: infants implanted at 6-12 months showed similar outcomes to children implanted at 12-24 months, at least through 2 to 2-1/2 years of age. This preliminary result may be associated with the difficulty of choosing appropriate stimulation parameters for infants, and its potential influence on the quality of the stimulation patterns delivered by the CI.

  20. Chondrosarcoma in Childhood: The Radiologic and Clinical Conundrum

    DTIC Science & Technology

    2012-12-01

    Radiology Case. 2012 Dec; 6(12):32-42 Pediatric Radiology: Chondrosarcoma in Childhood: The Radiologic and Clinical Conundrum Mosier et...w w w .R ad io lo g y C ases.co m 32 Chondrosarcoma in Childhood: The Radiologic and Clinical... chondrosarcomas occur in children. In addition, as little as 0.5% of low-grade chondrosarcomas arise secondarily from benign chondroid lesions

  1. Current trends in dental implants

    PubMed Central

    Gaviria, Laura; Salcido, John Paul; Guda, Teja

    2014-01-01

    Tooth loss is very a very common problem; therefore, the use of dental implants is also a common practice. Although research on dental implant designs, materials and techniques has increased in the past few years and is expected to expand in the future, there is still a lot of work involved in the use of better biomaterials, implant design, surface modification and functionalization of surfaces to improve the long-term outcomes of the treatment. This paper provides a brief history and evolution of dental implants. It also describes the types of implants that have been developed, and the parameters that are presently used in the design of dental implants. Finally, it describes the trends that are employed to improve dental implant surfaces, and current technologies used for the analysis and design of the implants. PMID:24868501

  2. Guideline on cochlear implants.

    PubMed

    Manrique, Manuel; Ramos, Ángel; de Paula Vernetta, Carlos; Gil-Carcedo, Elisa; Lassaleta, Luis; Sanchez-Cuadrado, Isabel; Espinosa, Juan Manuel; Batuecas, Ángel; Cenjor, Carlos; Lavilla, María José; Núñez, Faustino; Cavalle, Laura; Huarte, Alicia

    2018-03-26

    In the last decade numerous hospitals have started to work with patients who are candidates for a cochlear implant (CI) and there have been numerous and relevant advances in the treatment of sensorineural hearing loss that extended the indications for cochlear implants. To provide a guideline on cochlear implants to specialists in otorhinolaryngology, other medical specialities, health authorities and society in general. The Scientific Committees of Otology, Otoneurology and Audiology from the Spanish Society of Otolaryngology and Head and Neck Surgery (SEORL-CCC), in a coordinated and agreed way, performed a review of the current state of CI based on the existing regulations and in the scientific publications referenced in the bibliography of the document drafted. The clinical guideline on cochlear implants provides information on: a) Definition and description of Cochlear Implant; b) Indications for cochlear implants; c) Organizational requirements for a cochlear implant programme. A clinical guideline on cochlear implants has been developed by a Committee of Experts of the SEORL-CCC, to help and guide all the health professionals involved in this field of CI in decision-making to treathearing impairment. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. [Structuralist reading of radiologic images].

    PubMed

    Wackenheim, A

    1984-02-01

    The author suggests analysing the radiological image according to classical principles of structuralism, gestaltism, semiology, semantics. He describes applications in routine radiology: perception of complete theoretical displacement of parts of the image, phenomenology of three images (A-B-C) in theory and exams, mistake in perception by analogy.

  4. Treatment of acetabular fractures in older patients-introduction of a new implant for primary total hip arthroplasty.

    PubMed

    Resch, H; Krappinger, D; Moroder, P; Auffarth, A; Blauth, M; Becker, J

    2017-04-01

    Fractures of the acetabulum in younger patients are commonly treated by open reduction and internal fixation. For elderly patients, stable primary total hip arthroplasty with the advantage of immediate postoperative mobilization might be the adequate treatment. For this purpose, a sufficiently stable fixation of the acetabular component is required. Between August 2009 and 2014, 30 cases were reported in which all patients underwent total hip arthroplasty additionally to a customized implant designed as an antiprotrusion cage. Inclusion criteria were an acetabular fracture with or without a previous hemiarthroplasty, age above 65 years, and pre-injury mobility dependent on a walking frame at the most. The median age was 79.9 years (65-92), and of 30 fractures, 25 were primary acetabular fractures (83%), four periprosthetic acetabular fractures (14%), and one non-union after a failed ORIF (3%). The average time from injury to surgery was 9.4 days (3-23) and 295 days for the non-union case. Mean time of surgery was 154.4 min (range 100 to 303). In 21 cases (70%), mobilization with full weight bearing was possible within the first 10 days. Six patients died before the follow-up examination 3 and 6 months after surgery, while 24 patients underwent radiologic examination showing consolidated fractures in bi-plane radiographs. In 9 patients, additional CT scan was performed which confirmed the radiographical results. 13 had regained their pre-injury level of mobility including the non-union case. Only one patient did not regain independent mobility. Four complications were recognized with necessary surgical revision (one prosthetic head dislocation, one pelvic cement leakage, one femoral shaft fracture, and one infected hematoma). The presented cage provides the possibility of early mobilization with full weight bearing which represents a valuable addition to the treatment spectrum in this challenging patient group.

  5. Darwin als Sehhilfe für die Psychologie - Evolutionspsychologie

    NASA Astrophysics Data System (ADS)

    Schwab, Frank

    Im Folgenden geht es um Einäugige, stereoskopisches Sehen, weite und enge Horizonte, Monokel und Sonnenbrillen. Der Beitrag versucht die Metapher des Sehens und der Sehhilfen anzuwenden, um so zu verdeutlichen, welchen Gewinn die herkömmliche Psychologie durch die Verwendung einer Darwin'schen Brille erlangen kann.

  6. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis.

    PubMed

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. A MEDLINE (PubMed), Embase and Cochrane library search in combination with a hand-search of relevant journals was conducted. No language or year of publication restriction was applied. The search provided 298 titles. Three studies fulfilled the inclusion criteria. The included studies were characterized by low or moderate risk of bias. Survival of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone loss around implants with a scalloped implant-abutment connection. A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must be rejected. However, further long-term randomized controlled trials assessing implant treatment outcome with the two treatment modalities are needed before definite conclusions can be provided about the beneficial use of implants with a scalloped implant-abutment connection on preservation of the peri-implant marginal bone level.

  7. Paediatric musculoskeletal interventional radiology.

    PubMed

    Natali, Gian L; Paolantonio, Guglielmo; Fruhwirth, Rodolfo; Alvaro, Giuseppe; Parapatt, George K; Toma', Paolo; Rollo, Massimo

    2016-01-01

    Interventional radiology technique is now well established and widely used in the adult population. Through minimally invasive procedures, it increasingly replaces surgical interventions that involve higher percentages of invasiveness and, consequently, of morbidity and mortality. For these advantageous reasons, interventional radiology in recent years has spread to the paediatric age as well. The aim of this study was to review the literature on the development, use and perspectives of these procedures in the paediatric musculoskeletal field. Several topics are covered: osteomuscle neoplastic malignant and benign pathologies treated with invasive diagnostic and/or therapeutic procedures such as radiofrequency ablation in the osteoid osteoma; invasive and non-invasive procedures in vascular malformations; treatment of aneurysmal bone cysts; and role of interventional radiology in paediatric inflammatory and rheumatic inflammations. The positive results that have been generated with interventional radiology procedures in the paediatric field highly encourage both the development of new ad hoc materials, obviously adapted to young patients, as well as the improvement of such techniques, in consideration of the fact that childrens' pathologies do not always correspond to those of adults. In conclusion, as these interventional procedures have proven to be less invasive, with lower morbidity and mortality rates as well, they are becoming a viable and valid alternative to surgery in the paediatric population.

  8. Low Temperature Consolidation of Micro/Nanosilver Die-Attach Preforms

    NASA Astrophysics Data System (ADS)

    McCoppin, Jared; Reitz, Thomas L.; Miller, Ryan; Vijwani, Hema; Mukhopadhyay, Sharmila; Young, Daniel

    2014-09-01

    Organically passivated silver nanopowder paste-based sintering is considered a promising solution for die-attach in high temperature power and sensing electronic devices. However, oxygen requirements during burnout and inherently high shrinkage rates limit their use to small die sizes. This work reports an alternative fabrication method that resolves decomposition and shrinkage issues of the die-attach by utilizing a prestressed optimized tape cast mixture of micro- and nanosilver particles with a polypropylene carbonate binder. The effects of prestressing, micro/nanosilver bimodal distribution, and polymer content on resulting microstructure and shear strength were investigated. Prior to application as a die-attach, uniaxial compression of the tape was found to significantly decrease shrinkage and improve green strength. This pre-stressing strategy allows for a decoupling of the resulting die-attach materials properties from the pressure applied during assembly. Bimodal mixtures consisting of 1-3 μm spherical powders with nanosilver resulted in shear strengths comparable to those of pure nanosilver. Shear strength decreased as bimodal particle size increased above 5 μm. A polymer content of ˜10 wt.% polypropylene carbonate combined with prestressing was identified as optimal for maximizing die-attach shear strength while still maintaining pliability and formability. Tape casts that were prestressed to 212 MPa by uniaxially compression and formulated with 10 wt.% of polypropylene carbonate resulted in a die-attach material with a shear strength of 54 MPa when sintered. These materials were used to demonstrate void-free 25-mm2 die-attach assemblies, suggesting that tape cast micro/nanosilver materials may be a promising die-attach method for high temperature and large-area electronics devices.

  9. Digitalisierung und Energie 4.0 - Wie schaffen wir die digitale Energiewende?

    NASA Astrophysics Data System (ADS)

    Irlbeck, Maximilian

    Die digitale Energiewende verändert nachhaltig die Systeme der "alten" Energiewelt. Ein Zusammenwachsen verschiedener Domänen im Energiesystem, die durch digitale Technologie möglich wird, birgt enorme Herausforderungen, ist aber notwendig, um die Energiewende und ihre Ziele zu meistern. Dieser Beitrag beschreibt die Wirkung der Digitalisierung auf das Energiesystem, listet Charakteristika der digitalen Energiewende auf und schildert für verschiedene Domänen mögliche Zielvorstellungen, die durch digitale Technologie umsetzbar sind. Am Ende erläutert der Beitrag Handlungsschritte, die auf dem Weg zu einem erneuerbaren Energiesystem gegangen werden sollten und zeigt Probleme und Risiken einer Fehlentwicklung auf.

  10. The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants.

    PubMed

    Ward, W Kenneth; Slobodzian, Emily P; Tiekotter, Kenneth L; Wood, Michael D

    2002-11-01

    We addressed the effect of implant thickness, implant porosity, and polyurethane (PU) chemistry on angiogenesis and on the foreign body response in rats. The following materials were implanted subcutaneously for 7 weeks then excised for histologic analysis: a solid PU; a solid polyurethane with silicone and polyethylene oxide (PU-S-PEO); porous expanded polytetrafluoroethylene (ePTFE); and porous polyvinyl alcohol sponge (PVA). Two thicknesses of PU-S-PEO were compared: 300 microns (thin) and 2000 microns (thick). Foreign body capsule (FBC) thickness was much less in PU-S-PEO implants than in PU implants. In addition, FBC were thinner in thin implants than in thick implants. FBC was much more dense in solid implants than in porous implants. As compared with solid implants, porous implants (PVA and ePTFE) led to a marked increase in the number of microvessels that developed adjacent to the implant, as observed both with hematoxylin/eosin staining and with an immunohistochemical anti-endothelial stain. We conclude that the polyethylene oxide and silicone moieties in PU reduce the thickness of the subsequent FBC. In addition, thin implants lead to a thin FBC. Porous implants (PVA and ePTFE) cause more angiogenesis than solid implants. These results may have implications for the measurement of blood-derived analytes by biosensors.

  11. Organizational decentralization in radiology.

    PubMed

    Aas, I H Monrad

    2006-01-01

    At present, most hospitals have a department of radiology where images are captured and interpreted. Decentralization is the opposite of centralization and means 'away from the centre'. With a Picture Archiving and Communication System (PACS) and broadband communications, transmitting radiology images between sites will be far easier than before. Qualitative interviews of 26 resource persons were performed in Norway. There was a response rate of 90%. Decentralization of radiology interpretations seems less relevant than centralization, but several forms of decentralization have a role to play. The respondents mentioned several advantages, including exploitation of capacity and competence. They also mentioned several disadvantages, including splitting professional communities and reduced contact between radiologists and clinicians. With the new technology decentralization and centralization of image interpretation are important possibilities in organizational change. This will be important for the future of teleradiology.

  12. Classification of Radiological Changes in Burst Fractures

    PubMed Central

    Şentürk, Salim; Öğrenci, Ahmet; Gürçay, Ahmet Gürhan; Abdioğlu, Ahmet Atilla; Yaman, Onur; Özer, Ali Fahir

    2018-01-01

    AIM: Burst fractures can occur with different radiological images after high energy. We aimed to simplify radiological staging of burst fractures. METHODS: Eighty patients whom exposed spinal trauma and had burst fracture were evaluated concerning age, sex, fracture segment, neurological deficit, secondary organ injury and radiological changes that occurred. RESULTS: We performed a new classification in burst fractures at radiological images. CONCLUSIONS: According to this classification system, secondary organ injury and neurological deficit can be an indicator of energy exposure. If energy is high, the clinical status will be worse. Thus, we can get an idea about the likelihood of neurological deficit and secondary organ injuries. This classification has simplified the radiological staging of burst fractures and is a classification that gives a very accurate idea about the neurological condition. PMID:29531604

  13. Comparison of retention and stability of implant-retained overdentures based upon implant number and distribution.

    PubMed

    Scherer, Michael D; McGlumphy, Edwin A; Seghi, Robert R; Campagni, Wayne V

    2013-01-01

    The purpose of this investigation was to evaluate the effects of number and distribution of implants upon in vitro dislodging forces to a simulated implant-supported overdenture and to examine differences between several different attachment systems. An experiment was undertaken utilizing a model simulating a mandibular edentulous ridge with dental implants in positions on the model approximating tooth positions in the natural dentition. A cobalt-chromium-cast testing framework was used to measure the peak load required to disconnect an attachment. Four different types of commercially available attachments were used in various positions on the model in sequence to evaluate the effects of retention and stability of overdentures based on implant number and distribution: (1) ERA, (2) O-Ring, (3) Locator, and (4) Ball. For each group, 10 measurements were made of peak dislodging forces. Means were calculated and differences among the systems, directions, and groups were identified using a repeated measured analysis of variance (α = .05). The interactions between the attachment system, direction of force, and implant number and distribution were statistically significant. Vertical dislodging forces of the simulated overdenture prosthesis increased with additional widely spaced implants. Oblique dislodging forces of the simulated prosthesis increased with additional widely spaced implants except in the two-implant model with all attachments, and in the four-implant groups with Locator attachments. Anteroposterior dislodging forces of a simulated overdenture prosthesis increased with additional widely spaced implants except in the four-implant groups with Ball and Locator attachments. Ball attachments reported the highest levels of retention and stability followed by Locator, O-Ring, and ERA. Within the limitations of this study, retention and stability of an implant overdenture prosthesis are significantly affected by implant number, implant distribution, and abutment

  14. Resources planning for radiological incidents management

    NASA Astrophysics Data System (ADS)

    Hamid, Amy Hamijah binti Ab.; Rozan, Mohd Zaidi Abd; Ibrahim, Roliana; Deris, Safaai; Yunus, Muhd. Noor Muhd.

    2017-01-01

    Disastrous radiation and nuclear meltdown require an intricate scale of emergency health and social care capacity planning framework. In Malaysia, multiple agencies are responsible for implementing radiological and nuclear safety and security. This research project focused on the Radiological Trauma Triage (RTT) System. This system applies patient's classification based on their injury and level of radiation sickness. This classification prioritizes on the diagnostic and treatment of the casualties which include resources estimation of the medical delivery system supply and demand. Also, this system consists of the leading rescue agency organization and disaster coordinator, as well as the technical support and radiological medical response teams. This research implemented and developed the resources planning simulator for radiological incidents management. The objective of the simulator is to assist the authorities in planning their resources while managing the radiological incidents within the Internal Treatment Area (ITA), Reception Area Treatment (RAT) and Hospital Care Treatment (HCT) phases. The majority (75%) of the stakeholders and experts, who had been interviewed, witnessed and accepted that the simulator would be effective to resolve various types of disaster and resources management issues.

  15. The clinical, radiological, microbiological, and molecular profile of the skin‐penetration site of transfemoral amputees treated with bone‐anchored prostheses

    PubMed Central

    Lennerås, Maria; Tsikandylakis, Georgios; Trobos, Margarita; Omar, Omar; Vazirisani, Forugh; Palmquist, Anders; Berlin, Örjan; Brånemark, Rickard

    2016-01-01

    Abstract The breach of the skin barrier is a critical issue associated with the treatment of individuals with transfemoral amputation (TFA) using osseointegrated, percutaneous titanium implants. Thirty TFA patients scheduled for abutment exchange or removal were consecutively enrolled. The aims were to determine the macroscopic skin signs, the presence of bacteria and the gene expression in abutment‐adherent cells and to conduct correlative and comparative analyses between the different parameters. Redness and a granulation ring were present in 47% of the patients. Bacteria were detected in 27/30 patients, commonly in the bone canal. Staphylococcus aureus, coagulase‐negative staphylococci, streptococci, and Enterococcus faecalis were the most common. A positive correlation was found between TNF‐α expression and the detection of S. aureus. Staphylococcus aureus together with other bacterial species revealed a positive relationship with MMP‐8 expression. A negative correlation was demonstrated between the length of the residual femur bone and the detection of a granulation ring and E. faecalis. A positive correlation was revealed between fixture loosening and pain and the radiological detection of endosteal bone resorption. Fixture loosening was also correlated with the reduced expression of interleukin‐10 and osteocalcin. It is concluded that several relationships exist between clinical, radiological, microbiological, and molecular assessments of the percutaneous area of TFAs. Further long term studies on larger patient cohorts are required to determine the precise cause‐effect relationships and unravel the role of host‐bacteria interactions in the skin, bone canal and on the abutment for the longevity of percutaneous implants as treatment of TFA. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 578–589, 2017. PMID:27750392

  16. Towards a disposable in vivo miniature implantable fluorescence detector

    NASA Astrophysics Data System (ADS)

    Bellis, Stephen; Jackson, J. Carlton; Mathewson, Alan

    2006-02-01

    In the field of fluorescent microscopy, neuronal activity, diabetes and drug treatment are a few of the wide ranging biomedical applications that can be monitored with the use of dye markers. Historically, in-vivo fluorescent detectors consist of implantable probes coupled by optical fibre to sophisticated bench-top instrumentation. These systems typically use laser light to excite the fluorescent marker dies and using sensors, such as the photo-multiplier tube (PMT) or charge coupled devices (CCD), detect the fluorescent light that is filtered from the total excitation. Such systems are large and expensive. In this paper we highlight the first steps toward a fully implantable in-vivo fluorescence detection system. The aim is to make the detector system small, low cost and disposable. The current prototype is a hybrid platform consisting of a vertical cavity surface emitting laser (VCSEL) to provide the excitation and a filtered solid state Geiger mode avalanche photo-diode (APD) to detect the emitted fluorescence. Fluorescence detection requires measurement of extremely low levels of light so the proposed APD detectors combine the ability to count individual photons with the added advantage of being small in size. At present the exciter and sensor are mounted on a hybrid PCB inside a 3mm diameter glass tube.This is wired to external electronics, which provide quenching, photon counting and a PC interface. In this configuration, the set-up can be used for in-vitro experimentation and in-vivo analysis conducted on animals such as mice.

  17. Ethnic and Gender Diversity in Radiology Fellowships.

    PubMed

    West, Derek L; Nguyen, HaiThuy

    2017-06-01

    The purpose of the study is to assess ethnic and gender diversity in US radiology fellowship programs from 2006 to 2013. Data for this study was obtained from Journal of the American Medical Association supplements publications from 2005 to 2006 to 2012-2013 (Gonzalez-Moreno, Innov Manag Policy Pract. 15(2):149, 2013; Nivet, Acad Med. 86(12):1487-9, 2011; Reede, Health Aff. 22(4):91-3, 2003; Chapman et al., Radiology 270(1):232-40, 2014; Getto, 2005; Rivo and Satcher, JAMA 270(9):1074-8, 1993; Schwartz et al., Otolaryngol Head Neck Surg. 149(1):71-6, 2013; Simon, Clin Orthop Relat Res. 360:253-9, 1999) and the US census 2010. For each year, Fisher's exact test was used to compare the percentage of women and under-represented minorities in each Accreditation Council for Graduate Medical Education (ACGME)-certified radiology fellowship to the percentage of women and under-represented minorities in (1) all ACGME-certified radiology fellowships combined, (2) radiology residents, (3) ACGME-certified fellows in all of medicine combined, (4) ACGME-certified residents in all of medicine combined, and (5) graduating medical students. Chi-Squared test was used to compare the percentage of women and under-represented minorities and the 2010 US census. p < 0.05 was used as indicator of significance. Interventional radiology and neuroradiology demonstrated the highest levels of disparities, compared to every level of medical education. Abdominal and musculoskeletal radiology fellowships demonstrated disparity patterns consistent with lack of female and URM medical graduates entering into radiology residency. All radiology fellowships demonstrated variable levels of gender and ethnic disparities. Outreach efforts, pipeline programs, and mentoring may be helpful in addressing this issue.

  18. In Vivo Response of Laser Processed Porous Titanium Implants for Load-Bearing Implants.

    PubMed

    Bandyopadhyay, Amit; Shivaram, Anish; Tarafder, Solaiman; Sahasrabudhe, Himanshu; Banerjee, Dishary; Bose, Susmita

    2017-01-01

    Applications of porous metallic implants to enhance osseointegration of load-bearing implants are increasing. In this work, porous titanium implants, with 25 vol.% porosity, were manufactured using Laser Engineered Net Shaping (LENS™) to measure the influence of porosity towards bone tissue integration in vivo. Surfaces of the LENS™ processed porous Ti implants were further modified with TiO 2 nanotubes to improve cytocompatibility of these implants. We hypothesized that interconnected porosity created via additive manufacturing will enhance bone tissue integration in vivo. To test our hypothesis, in vivo experiments using a distal femur model of male Sprague-Dawley rats were performed for a period of 4 and 10 weeks. In vivo samples were characterized via micro-computed tomography (CT), histological imaging, scanning electron microscopy, and mechanical push-out tests. Our results indicate that porosity played an important role to establish early stage osseointegration forming strong interfacial bonding between the porous implants and the surrounding tissue, with or without surface modification, compared to dense Ti implants used as a control.

  19. In vivo response of laser processed porous titanium implants for load-bearing implants

    PubMed Central

    Bandyopadhyay, Amit; Shivaram, Anish; Tarafder, Solaiman; Sahasrabudhe, Himanshu; Banerjee, Dishary; Bose, Susmita

    2016-01-01

    Applications of porous metallic implants to enhance osseointegration of load-bearing implants are increasing. In this work, porous titanium implants, with 25 volume% porosity, were manufactured using Laser Engineered Net Shaping (LENS™) to measure the influence of porosity towards bone tissue integration in vivo. Surfaces of the LENS™ processed porous Ti implants were further modified with TiO2 nanotubes to improve cytocompatibility of these implants. We hypothesized that interconnected porosity created via additive manufacturing will enhance bone tissue integration in vivo. To test our hypothesis, in vivo experiments using a distal femur model of male Sprague-Dawley rats were performed for a period of 4 and 10 weeks. In vivo samples were characterized via micro-computed tomography (CT), histological imaging, scanning electron microscopy, and mechanical push-out tests. Our results indicate that porosity played an important role to establish early stage osseointegration forming strong interfacial bonding between the porous implants and the surrounding tissue, with or without surface modification, compared to dense Ti implants used as a control. PMID:27307009

  20. A web based Foundations of Radiological Physics for diagnostic radiology residents.

    PubMed

    Blackmon, Kevin N; Huda, Walter; Lewis, Madelene C; Tipnis, Sameer; Mah, Eugene; Frey, Donald G

    2013-03-01

    RATIONALE AND OBJECTS: We describe a new web-based physics course for radiology residents preparing for the Exam of the Future (EOF). A course was developed with a total of 12 web-based modules. Six modules were focused on "imaging" and six on "radiation." A module was subdivided into nine short "nuggets." Traditional lectures were replaced by modules using prerecorded lectures (Tegrity) to a secure website (WebCT). Each module was accompanied by three quizzes, each consisting of ten questions designed to reinforce covered materials. All online modules were accompanied by a noon conference that employed an Audience Response System (Turning Point). Seventeen first-year residents over 2 consecutive years beginning in July 2010 took this new course, and participated in an anonymous online follow-up survey (Survey Monkey). The recorded 12 modules had an overall average duration of 72 ± 19 minutes. Ten of 17 residents expressed a preference of 15 minutes for nugget duration. Highest personal assessment scores of each resident's understanding were obtained in human radiation risks and radiation protection. Residents considered supplemental noon conferences to be important for learning radiological physics. Satisfaction level was largely positive, with five residents highly satisfied, nine residents somewhat satisfied, two residents neutral, and only one resident somewhat dissatisfied. Our Foundations of Radiological Physics course was well received and served as the springboard for mastering x-ray-based imaging modalities of radiography, mammography, fluoroscopy, interventional radiology, and computed tomography. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  1. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis

    PubMed Central

    Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    ABSTRACT Objectives The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. Material and Methods A MEDLINE (PubMed), Embase and Cochrane library search in combination with a hand-search of relevant journals was conducted. No language or year of publication restriction was applied. Results The search provided 298 titles. Three studies fulfilled the inclusion criteria. The included studies were characterized by low or moderate risk of bias. Survival of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone loss around implants with a scalloped implant-abutment connection. Conclusions A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must be rejected. However, further long-term randomized controlled trials assessing implant treatment outcome with the two treatment modalities are needed before definite conclusions can be provided about the beneficial use of implants with a scalloped implant-abutment connection on preservation of the peri-implant marginal bone level. PMID:28496962

  2. Killing, letting die and euthanasia.

    PubMed Central

    Husak, D N

    1979-01-01

    Medical ethicists debate whether or not the moral assessment of cases of euthanasia should depend on whether the patient is 'killed' or 'allowed to die'. The usual presupposition is that a clear distinction between killing and letting die can be drawn so that this substantive question is not begged. I contend that the categorisation of cases of instances of killing rather than as instances of letting die depends in part on a prior moral assessment of the case. Hence is it trivially rather than substantively true that the distinction has moral significance. But even if a morally neutral (ie non-question begging) distinction could be drawn, its application to the euthanasia controversy is problematic. I illustrate the difficulties of employing this distinction to reach moral conclusions by critically discussing Philippa Foot's recent treatment of euthanasia. I conclude that even if an act of euthanasia is an instance of killing, and there exists a prima facie moral duty not to kill, and no more stringent duty overrides this duty, one still cannot determine such an act to be morally impermissible. PMID:541821

  3. Killing, letting die and euthanasia.

    PubMed

    Husak, D N

    1979-12-01

    Medical ethicists debate whether or not the moral assessment of cases of euthanasia should depend on whether the patient is 'killed' or 'allowed to die'. The usual presupposition is that a clear distinction between killing and letting die can be drawn so that this substantive question is not begged. I contend that the categorisation of cases of instances of killing rather than as instances of letting die depends in part on a prior moral assessment of the case. Hence is it trivially rather than substantively true that the distinction has moral significance. But even if a morally neutral (ie non-question begging) distinction could be drawn, its application to the euthanasia controversy is problematic. I illustrate the difficulties of employing this distinction to reach moral conclusions by critically discussing Philippa Foot's recent treatment of euthanasia. I conclude that even if an act of euthanasia is an instance of killing, and there exists a prima facie moral duty not to kill, and no more stringent duty overrides this duty, one still cannot determine such an act to be morally impermissible.

  4. Nanotechnology for dental implants.

    PubMed

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  5. Death and Dying: Issues for Educational Gerontologists.

    ERIC Educational Resources Information Center

    Wass, Hannelore, Myers, Jane E.

    1984-01-01

    Reviews research on death orientations, the dying process, and bereavement, with a major focus on the elderly. Suggests that relevant knowledge about death and dying are important for gerontological practitioners and proposes that death-related content be systematically integrated into academic curricula at the preservice and inservice levels.…

  6. A Retrospective Analysis of Dental Implants Replacing Failed Implants in Grafted Maxillary Sinus: A Case Series.

    PubMed

    Manor, Yifat; Chaushu, Gavriel; Lorean, Adi; Mijiritzky, Eithan

    2015-01-01

    To evaluate the survival rate of dental implants replacing failed implants in grafted maxillary sinuses using the lateral approach vs nongrafted posterior maxillae. A retrospective analysis was conducted to study the survival of secondary dental implants inserted in the posterior maxilla in previously failed implant sites between the years 2000 and 2010. The study group consisted of patients who had also undergone maxillary sinus augmentation, and the control group consisted of patients in whom implants in the posterior maxilla had failed. Clinical and demographic data were analyzed using a structured form. Seventy-five patients with a total of 75 replaced implants were included in the study. The study group comprised 40 patients and the control group, 35 patients. None of the replaced implants in the study group failed, resulting in an overall survival of 100%; three replaced implants in the control group failed (92% survival). The main reason for the primary implant removal was lack of osseointegration (35 [87.5%] of 40 study group implants and 23 [65.7%] of 35 control group implants [P = .027]). The difference between the groups with regard to the timing of primary implant failure was statistically significant. The study group had more early failures of the primary implant than did the control group (77% vs 62%; P = .038). Dental implants replaced in the posterior maxilla had a high survival rate. A higher rate of survival was found in augmented maxillary sinus sites. Within the limits of the present study, it can be concluded that previous implant failures in the grafted maxillary sinus should not discourage practitioners from a second attempt.

  7. One-step breast reconstruction with polyurethane-covered implants after skin-sparing mastectomy.

    PubMed

    Rancati, Alberto; Soderini, Alejandro; Dorr, Julio; Gercovich, Gustavo; Tessari, Luciano; Gonzalez, Eduardo

    2013-12-01

    Skin-sparing mastectomy (SSM) and immediate one-step breast reconstruction with implants has become an increasingly popular, effective treatment for selected patients with breast carcinoma. However, it is associated with high complication rates. Breast augmentation with polyurethane-covered implants (PCIs) has consistently had optimal short-term and long-term results with low rates of capsular contracture. The aim of this study was to evaluate the clinical and aesthetic outcomes of immediate one-step breast reconstruction with PCI after SSM in early breast cancer patients at a single institution. We reviewed the records of 221 consecutive breast cancer patients who underwent one-stage immediate reconstruction with PCI after SSM from 1995 through 2005. Patient and tumour characteristics, type of reconstruction, postoperative complications, aesthetic results and recurrence rate were analysed. The mean age of the patients was 52±11 years (range, 30-76; standard deviation (SD), 11). The American Joint Committee on Cancer (AJCC) pathologic stages were 0 (10%), I (63.3%) and II (26.7%). Thirty-nine (17.65%; confidence interval (CI)=13.04-23.1) of the 221 patients had complications; seven had prosthesis extrusion requiring an implant (five due to skin necrosis, one due to infection and one due to late haematoma). In six of these seven cases, the procedure was indicated for local recurrence after conservative breast surgery with adjunctive radiation therapy (rescue procedure). Thirty-two (14.4%) patients had minor complications: 12 had cutaneous rash, four had malpositioned implants and 16 had inadequate implant projection. At long-term follow-up, four (1.8%) patients had developed grade IV capsular contracture associated with postoperative radiation therapy. At a median follow-up of 98 months (range, 36-156), 14 (6.3%) patients had tumour recurrence and 12.2% had distant metastasis. Nineteen patients had died of cancer, and 192 (86.8%) remained disease free. One

  8. Dental-Implantate und ihre Werkstoffe

    NASA Astrophysics Data System (ADS)

    Newesely, Heinrich

    1983-07-01

    Some new trends in materials for dental implants, which also effect in the operative techniques and implant design, are described. Advantages and shortcomings of the different material types are exemplified and correlated with their bioinert resp. bioactive functions. The practical interest in metallic implants focussed in titanium resp. oxide ceramics in the ceramic field, whereas the special goal of implant research follows from the improvement of the bioactive principle with loaded calcium phosphate implants.

  9. How to Read Your Radiology Report

    MedlinePlus

    ... Index A-Z How to Read Your Radiology Report Imaging studies such as magnetic resonance imaging (MRI), ... report. top of page Sections of the Radiology Report Type of exam The type of exam section ...

  10. Vancomycin and tobramycin impregnated mineralized allograft for the surgical regenerative treatment of peri-implantitis: a 1-year follow-up case series.

    PubMed

    Nart, José; de Tapia, Beatriz; Pujol, Àngels; Pascual, Andrés; Valles, Cristina

    2017-12-24

    To assess the clinical and radiographic outcomes of the regenerative treatment of peri-implantitis using a vancomycin and tobramycin impregnated allograft (VTA) after a 12-month period. Thirteen consecutive patients who required a regenerative treatment of peri-implantitis were recruited. For the 17 implant sites, a flap was raised, and after mechanical and chemical implant decontamination, a vancomycin and tobramycin impregnated allograft was placed in the defect and then covered with a collagen membrane. Soft tissues were sutured allowing a non-submerged healing. Clinical and radiographic variables were evaluated at baseline and at 12 months after treatment. No signs of continuous bone loss were observed and no implant was lost, yielding a 100% survival rate. All patient's clinical examination at 12 months revealed peri-implant health showing absence of suppuration and a statistically significant reduction in terms of bleeding on probing scores (70.6%, P = 0.001). Initial probing pocket depth (7.88 ± 1.22 mm) was significantly reduced at 12 months healing, a mean reduction of 4.23 ± 1.47 mm (P = 0.001) was achieved. The mean radiological infrabony defect at baseline reached 4.33 ± 1.62 mm, and was significantly reduced up to 0.56 ± 0.88 mm, which represents an 86.99 ± 18.2% bone fill from the original infrabony defect. Within the limits of the study, the application of VTA with a collagen membrane yielded positive outcomes in terms of radiographic bone fill, pocket depth reduction, and attachment gain after a 12-month period. Thus, VTA plus a collagen membrane seem to be suitable for the regenerative treatment of peri-implantitis. The use of locally delivered antibiotic together with the bone graft may reduce the undesirable effects related to the systemic administration and the risk of resistances. In the light of the results obtained, these grafting materials might offer new treatment strategies in the surgical

  11. Environmental radiology assessment in Lahad Datu, Sabah

    NASA Astrophysics Data System (ADS)

    Siti Fharhana, Yusof; Wan Muhamad Saridan, Wan Hassan; Ahmad Termizi, Ramli; Mohd Hilmi, Sahini; Mohammad Syazwan, Mohd Sanusi; Nor Afifah, Basri; Nor Zati Hani, Abu Hanifah

    2017-10-01

    Monitoring terrestial gamma radiation is crucial to prepare a baseline data for environmental radiological protection. Radiological research was carried out in Lahad Datu, Sabah to obtain the radioactivity status and terrestrial gamma radiation level in the area. We measure the terrestrial gamma radiation dose rates and analyse the radioactivity concentration of primordial radionuclides for radiological risk assessment. We identified that the annual estimation of dose effective for public is below the public dose limit, 1 mSv per year. Public and environment safety and health are remain secure. The obtained data and results can be used as reference for environmental radiology protection.

  12. Kundenfokus: Startpunkt für die digitale Transformation bei Stadtwerken

    NASA Astrophysics Data System (ADS)

    Fett, Perry; Küller, Philipp

    Big Data, Internet der Dinge, Mobile Computing und soziale Medien - die modernen Informationstechnologien durchdringen den Alltag der meisten Menschen und lösen hierdurch eine digitale Transformation aus. Im Unternehmenskontext manifestiert sich die Digitalisierung durch eine neue Qualität der wissensbasierten Entscheidungsunterstützung und der Automatisierung bzw. Autonomisierung der Geschäftsprozesse. Für Stadtwerke gilt es nun, die Chancen der Digitalisierung zu ihren Gunsten zu nutzen. Ein Startpunkt könnte hierbei sein, wie Stadtwerke zukünftig mit ihren Kunden interagieren. Ausgelöst durch die Liberalisierung der Märkte rückt der Kunde heute stärker in den Mittelpunkt - die Energiewirtschaft steht nun vor der Herausforderung, dem Wettbewerb einen Schritt voraus zu sein und dem Kunden ein absolut positives Kundenerlebnis (Customer Experience) sowohl als Maßnahme zur Kundenbindung als auch zum Kundenaufbau zu bieten. Das vorliegende Kapitel zeigt hierfür die Erfolgskriterien für die gelungene Etablierung des Kundenfokus im eigenen Unternehmen auf. Mit dem Customer-Focus-Cycle-Modell von Fujitsu, angelehnt an den Deming-Kreislauf, wird ein allgemeingültiger Ansatz für ein mögliches Vorgehen beim Aufbau des Kundenfokus vorgestellt. Die sechs Phasen werden dabei anhand praktischer Beispiele erläutert und geben zudem Hinweise zu Methoden und Tools. Aus dem vorgestellten "Werkzeugkasten" wird ferner die Customer-Journey-Methode im Detail erläutert. Weiter soll das präsentierte Reifegradmodell Unternehmen dabei unterstützen, den eigenen Status quo festzustellen und die persönlichen Ziele auf dem Weg zur kundenzentrierten Organisation festzulegen.

  13. Reversing the polarity of a cochlear implant magnet after magnetic resonance imaging.

    PubMed

    Jeon, Ju Hyun; Bae, Mi Ran; Chang, Jae Won; Choi, Jae Young

    2012-08-01

    The number of patients with cochlear implant (CI) has been rapidly increasing in recent years, and these patients show a growing need of examination by magnetic resonance imaging (MRI). However, the use of MRI on patients with CI is restricted by the internal magnet of the CI. Many studies have investigated the safety of performing 1.5T MRI on patients with CI, which is now being practiced in a clinical setting. We experienced a case in which the polarity of the cochlear implant magnet was reversed after the patient was examined using 1.5T MRI. The external device was attached to the internal device oppositely. We could not find displacement of the internal device, magnet, or electrode upon radiological evaluation. We came up with two possible mechanisms by which the polarity of the magnet reversed. The first possibility was that the magnetic field of MRI reversed the polarity of the magnet. The second was that the internal magnet was physically realigned while interacting with the MRI. We believe the second hypothesis to be more reliable. A removable magnet and a loose magnet boundary of a CI device may have allowed for physical reorientation of the internal magnet. Therefore, in order to avoid these complications, first, the internal magnet must not be aligned anti-parallel with the magnetic polarity of MRI. In the Siemens MRI, the vector of the magnetic field is downward, so implant site should be placed in facing upwards to minimize demagnetization. In the GE Medical Systems MRI, the vector of the magnetic field is upward, so the implant site should be placed facing downwards. Second, wearing of a commercial mold which is fixed to the internal device before performing MRI can be helpful. In addition, any removable internal magnets in a CI device should be removed before MRI, especially in the trunk. However, to ultimately solve this problem, the pocket of the internal magnet should be redesigned for safety. Copyright © 2011. Published by Elsevier Ireland Ltd.

  14. Why do older people oppose physician-assisted dying? A qualitative study.

    PubMed

    Malpas, Phillipa J; Wilson, Maria K R; Rae, Nicola; Johnson, Malcolm

    2014-04-01

    Physician-assisted dying at the end of life has become a significant issue of public discussion. While legally available in a number of countries and jurisdictions, it remains controversial and illegal in New Zealand. The study aimed to explore the reasons some healthy older New Zealanders oppose physician-assisted dying in order to inform current debate. Recorded interviews were transcribed and analysed by the authors after some edits had been made by respondents. In all, 11 older participants (over 65 years) who responded to advertisements placed in Grey Power magazines and a University of Auckland email list were interviewed for around 1 h and asked a number of open-ended questions. Four central themes opposing physician-assisted dying were identified from the interviews: one's personal experience with health care and dying and death, religious reasoning and beliefs, slippery slope worries and concern about potential abuses if physician-assisted dying were legalised. An important finding of the study suggests that how some older individuals think about physician-assisted dying is strongly influenced by their past experiences of dying and death. While some participants had witnessed good, well-managed dying and death experiences which confirmed for them the view that physician-assisted dying was unnecessary, those who had witnessed poor dying and death experiences opposed physician-assisted dying on the grounds that such practices could come to be abused by others.

  15. Sensitivity of autopsy and radiological examination in detecting bone fractures in an animal model: implications for the assessment of fatal child physical abuse.

    PubMed

    Cattaneo, C; Marinelli, E; Di Giancamillo, A; Di Giancamillo, M; Travetti, O; Vigano', L; Poppa, P; Porta, D; Gentilomo, A; Grandi, M

    2006-12-20

    Skeletal injuries are often strong indicators of child abuse and their detection is therefore crucial. The aim of this study was to compare the sensitivity of three diagnostic approaches, namely autopsy, traditional (conventional) radiology, and computed tomography on "battered" piglets, in order to verify the sensitivity of each method, with respect to the true number of bone fractures assessed once the piglet was skeletonised (osteological control). Four newborn cadaver piglets who had died from natural causes were severely beaten post-mortem in every district of the body. Traditional radiography, computed tomography (CT) and autopsy were performed. The piglet was then macerated until skeletonised and the number of all fractures present recorded (osteological control). On the cranium, traditional radiology revealed only 35% circa of actual fractures, autopsy detected only 31% (P<0.01 for both comparisons versus osteological control), whereas CT imaging detected all fractures actually present. For ribs, radiology detected only 47% of all fractures present, and autopsy 65% circa (P>0.05 for both comparisons versus osteological control), while CT scans detected 34% (P<0.01). In suspected cases of fatal child abuse, we suggest that the bones of specific districts be directly analysed either at autopsy or by collecting specific diagnostic sites, such as parts of the rib cage, and subjecting them to maceration. The removed areas could be replaced with artificial material for cosmetic purposes. The authors stress the importance of combined radiological, CT scan, autopsy and osteological survey in the detection of perimortem bone fractures.

  16. Clinical and radiological results on the fixation of Neer type 2 distal clavicle fractures with a hook plate.

    PubMed

    Şükür, Erhan; Öztürkmen, Yusuf; Akman, Yunus Emre; Güngör, Mustafa

    2016-10-01

    The aim of this study was to analyze the clinical and functional results of hook plate fixation in Neer type 2 distal clavicle fractures. We retrospectively analyzed 16 patients (11 males, 5 females) who were diagnosed with Neer type 2 distal clavicle fractures and treated with hook plate fixation between 2013 and 2014. Mean age was 38 (range: 27-61), and mean follow-up time was 14.3 (range: 12-18) months. Complications seen on radiographs were implant failure and subacromial osteolysis. The clinical results were evaluated with modified UCLA (University of California Los Angeles) scoring system. Bone union was achieved in all patients at the end of the first 4 months. Mean modified UCLA score was 32.75 (range 31-35). In 12 patients (68%), the implants had to be removed due to complications. After removal, the complaints regressed and shoulders' range of motion increased. Clinical and radiological results on the fixation of Neer type 2 distal clavicle fractures with a hook plate are good in terms of fracture union and function. The major disadvantage of the method was the requirement of early implant removal due to the hardware related complications and good results can be achieved only after plate removal. Optimizing the length of hook plate may lower the rate of complications. Level IV, Therapeutic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  17. Implant retention systems for implant-retained overdentures.

    PubMed

    Laverty, D P; Green, D; Marrison, D; Addy, L; Thomas, M B M

    2017-03-10

    Implant retained overdentures are being increasingly utilised in both general and specialist practice to rehabilitate patients with missing teeth, particularly those that are edentate. This article aims to inform the reader of a variety of retention systems that are available to retain an implant overdenture and to understand how these systems work, their advantages and disadvantages and to outline some of the clinical and treatment planning considerations involved in selecting the most appropriate retention system for patients.

  18. Incidence of Radiologically Isolated Syndrome: A Population-Based Study.

    PubMed

    Forslin, Y; Granberg, T; Jumah, A Antwan; Shams, S; Aspelin, P; Kristoffersen-Wiberg, M; Martola, J; Fredrikson, S

    2016-06-01

    Incidental MR imaging findings resembling MS in asymptomatic individuals, fulfilling the Okuda criteria, are termed "radiologically isolated syndrome." Those with radiologically isolated syndrome are at high risk of their condition converting to MS. The epidemiology of radiologically isolated syndrome remains largely unknown, and there are no population-based studies, to our knowledge. Our aim was to study the population-based incidence of radiologically isolated syndrome in a high-incidence region for MS and to evaluate the effect on radiologically isolated syndrome incidence when revising the original radiologically isolated syndrome criteria by using the latest radiologic classification for dissemination in space. All 2272 brain MR imaging scans in 1907 persons obtained during 2013 in the Swedish county of Västmanland, with a population of 259,000 inhabitants, were blindly evaluated by a senior radiologist and a senior neuroradiologist. The Okuda criteria for radiologically isolated syndrome were applied by using both the Barkhof and Swanton classifications for dissemination in space. Assessments of clinical data were performed by a radiology resident and a senior neurologist. The cumulative incidence of radiologically isolated syndrome was 2 patients (0.1%), equaling an incidence rate of 0.8 cases per 100,000 person-years, in a region with an incidence rate of MS of 10.2 cases per 100,000 person-years. There was no difference in the radiologically isolated syndrome incidence rate when applying a modified version of the Okuda criteria by using the newer Swanton classification for dissemination in space. Radiologically isolated syndrome is uncommon in a high-incidence region for MS. Adapting the Okuda criteria to use the dissemination in space-Swanton classification may be feasible. Future studies on radiologically isolated syndrome may benefit from a collaborative approach to ensure adequate numbers of participants. © 2016 by American Journal of Neuroradiology.

  19. Effect of implant angulation and impression technique on impressions of NobelActive implants.

    PubMed

    Alexander Hazboun, Gillian Brewer; Masri, Radi; Romberg, Elaine; Kempler, Joanna; Driscoll, Carl F

    2015-05-01

    How the configuration of the NobelActive internal conical connection affects implant impressions is uncertain. The purpose of this study was to measure the effect in vitro of closed and open tray impression techniques for NobelActive implants placed at various angulations. Six NobelActive implants were placed in a master maxillary cast as follows: 0 degrees of angulation to a line drawn perpendicular to the occlusal plane in the first molar area, 15 degrees of angulation to a line drawn perpendicular to the occlusal plane in the first premolar area, and 30 degrees of angulation to a line drawn perpendicular to the occlusal plane in the lateral incisor area. Twelve open tray and 12 closed tray impressions were made. Occlusal, lateral, and frontal view photographs of the resulting casts were used to measure the linear and angular displacement of implant analogs. Statistical analysis was performed with a factorial analysis of variance (ANOVA), followed by the Tukey HSD test (α=.05). No significant difference was found in the impressions made of NobelActive implants with the open or closed tray technique (linear displacement: F=0.93, P=.34; angular displacement: F=2.09, P=.15). In addition, implant angulation (0, 15, or 30 degrees) had no effect on the linear or angular displacement of impressions (linear displacement: F=2.72, P=.07; angular displacement: F=0.86, P=.43). Finally, no significant interaction was found between impression technique and implant angulation on NobelActive implants (F=0.25, P=.77; F=1.60, P=.20). Within the limitations of this study, impression technique (open vs closed tray) and implant angulation (0, 15, and 30 degrees) had no significant effect on in vitro impressions of NobelActive implants. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. The value proposition of structured reporting in interventional radiology.

    PubMed

    Durack, Jeremy C

    2014-10-01

    The purposes of this article are to provide a brief overview of structured radiology reporting and to emphasize the anticipated benefits from a new generation of standardized interventional radiology procedure reports. Radiology reporting standards and tools have evolved to enable automated data integration from multiple institutions using structured templates. In interventional radiology, data aggregated into clinical, research and quality registries from enriched structured reports could firmly establish the interventional radiology value proposition.

  1. Comprehensive Health Care Economics Curriculum and Training in Radiology Residency.

    PubMed

    Keiper, Mark; Donovan, Timothy; DeVries, Matthew

    2018-06-01

    To investigate the ability to successfully develop and institute a comprehensive health care economics skills curriculum in radiology residency training utilizing didactic lectures, case scenario exercises, and residency miniretreats. A comprehensive health care economics skills curriculum was developed to significantly expand upon the basic ACGME radiology residency milestone System-Based Practice, SBP2: Health Care Economics requirements and include additional education in business and contract negotiation, radiology sales and marketing, and governmental and private payers' influence in the practice of radiology. A health care economics curriculum for radiology residents incorporating three phases of education was developed and implemented. Phase 1 of the curriculum constituted basic education through didactic lectures covering System-Based Practice, SBP2: Health Care Economics requirements. Phase 2 constituted further, more advanced didactic lectures on radiology sales and marketing techniques as well as government and private insurers' role in the business of radiology. Phase 3 applied knowledge attained from the initial two phases to real-life case scenario exercises and radiology department business miniretreats with the remainder of the radiology department. A health care economics skills curriculum in radiology residency is attainable and essential in the education of future radiology residents in the ever-changing climate of health care economics. Institution of more comprehensive programs will likely maximize the long-term success of radiology as a specialty by identifying and educating future leaders in the field of radiology. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  2. Death and help expected from nurses when dying.

    PubMed

    Shih, Fu-Jin; Gau, Meei-Ling; Lin, Yaw-Sheng; Pong, Suang-Jing; Lin, Hung-Ru

    2006-07-01

    This project was undertaken to ascertain the perceptions of a group of Taiwan's fourth-year bachelor of science in nursing (BSN) students regarding death and help expected from nurses during the dying process. Within the Chinese culture, death is one of the most important life issues. However, in many Chinese societies it is difficult for people to reveal their deepest feelings to their significant others or loved ones. It was in this context that this project was developed because little is known about how Taiwan's nursing students perceive death and the dying process. Using an open-ended, self-report questionnaire, 110 senior BSN students recorded their thoughts on: (1) their fears before physical death; (2) afterlife destinations; and (3) the help they would expect from nurses when dying. The data were analyzed using a three-layer qualitative thematic analysis. The students' reported needs during the dying process were directed towards three main goals: (1) help in reaching the 'triple targets of individual life'; (2) help in facilitating in-depth support so that both the dying person and significant others can experience a blessed farewell; and (3) help in reaching a destination in the afterlife. The results support the belief of dying as a transition occurring when life weans itself from the mortal world and prepares for an afterlife.

  3. The evolution of radiology from paraclinical to clinical.

    PubMed

    Boey, Hong Khim

    2009-07-01

    The perception of Radiology in the early 60s as paraclinical stems from the poor image the clinicians had for our limited resources in providing only plain fi lm studies, VIPs and the single contrast barium studies which exclude only gross lesions. The evolution to clinical status started as early as the mid 60s. My personal recollection and reflection of the histological events that took place covered here highlights the reasons for the transformation from paraclinical to clinical and these form the main theme for this paper. Radiologists' professionalism plays an infinite part in the evolution to clinical Radiology. Rapid technological advances in imaging help to propel Radiology to the forefront. But credit must go to the individual Radiologist for their personal efforts and contributions. Reflection on past events of Radiology in Singapore leading to the establishment of Clinical Radiology was presented. The future of Radiology is brought up for discussion on the role of Radiologists with reference to subspecialisation necessitated by the ever increasing advances in Medical Imaging and demand for Interventional Radiology.

  4. Radiology practice in Latin America: a literature review.

    PubMed

    Teague, Jordan

    2013-01-01

    To discover the status and structure of radiology in Latin America with respect to the health care systems it is part of, the effects of socioeconomics, the equipment and technology used, technologists and their training, accreditation, and professional organizations. Health-related databases and Google Scholar were searched for articles concerning radiology practice in Latin America. Articles were selected based on relevance to the research scope. Many regions in Latin America offer little to no access to radiology. Where there is access, the equipment often is old or not functioning, with limited and costly service and maintenance. Most trained technologists live in urban areas. There are no standardized accreditation practices in Latin America. However, forming professional organizations would help promote the practice of radiology and accreditation standards. International cooperative organizations enhance radiology by providing resources and opportunities for cooperation between countries. The current status of radiology in Latin America must be determined. This knowledge will help us discover opportunities for cooperation and ways to improve radiology practice. The main need in Latin America is to extend coverage to the underserved population.

  5. Towards deployable meta-implants.

    PubMed

    Bobbert, F S L; Janbaz, S; Zadpoor, A A

    2018-06-07

    Meta-biomaterials exhibit unprecedented or rare combinations of properties not usually found in nature. Such unusual mechanical, mass transport, and biological properties could be used to develop novel categories of orthopedic implants with superior performance, otherwise known as meta-implants. Here, we use bi-stable elements working on the basis of snap-through instability to design deployable meta-implants. Deployable meta-implants are compact in their retracted state, allowing them to be brought to the surgical site with minimum invasiveness. Once in place, they are deployed to take their full-size load-bearing shape. We designed five types of meta-implants by arranging bi-stable elements in such a way to obtain a radially-deployable structure, three types of auxetic structures, and an axially-deployable structure. The intermediate stable conditions ( i.e. multi-stability features), deployment force, and stiffness of the meta-implants were found to be strongly dependent on the geometrical parameters of the bi-stable elements as well as on their arrangement.

  6. Radiological incident preparedness: planning at the local level.

    PubMed

    Tan, Clive M; Barnett, Daniel J; Stolz, Adam J; Links, Jonathan M

    2011-03-01

    Radiological terrorism has been recognized as a probable scenario with high impact. Radiological preparedness planning at the federal and state levels has been encouraging, but translating complex doctrines into operational readiness at the local level has proved challenging. Based on the authors' experience with radiological response planning for the City of Baltimore, this article describes an integrated approach to municipal-level radiological emergency preparedness planning, provides information on resources that are useful for radiological preparedness planning, and recommends a step-by-step process toward developing the plan with relevant examples from the experience in Baltimore. Local governmental agencies constitute the first line of response and are critical to the success of the operation. This article is intended as a starting framework for local governmental efforts toward developing a response plan for radiological incidents in their communities.

  7. Paint for detection of radiological or chemical agents

    DOEpatents

    Farmer, Joseph C [Tracy, CA; Brunk, James L [Martinez, CA; Day, Sumner Daniel [Danville, CA

    2010-08-24

    A paint that warns of radiological or chemical substances comprising a paint operatively connected to the surface, an indicator material carried by the paint that provides an indication of the radiological or chemical substances, and a thermo-activation material carried by the paint. In one embodiment, a method of warning of radiological or chemical substances comprising the steps of painting a surface with an indicator material, and monitoring the surface for indications of the radiological or chemical substances. In another embodiment, a paint is operatively connected to a vehicle and an indicator material is carried by the paint that provides an indication of the radiological or chemical substances.

  8. Justification and radiology: some ethical considerations.

    PubMed

    Sia, Santiago

    2009-07-01

    This paper, which seeks to address the issue of justification in radiology, intends firstly to comment on the current discussion of the ethical foundation of radiological practice that focuses on the move from utilitarianism to the rights-centred criterion. Secondly, and this constitutes the bulk of the paper, it aims to offer a philosophical perspective, which is hoped will lead to a consideration of certain specific areas in ethical decision-making in the attempts here to deal with the main issue of justification in radiology.

  9. Cascaded die mountings with spring-loaded contact-bond options

    DOEpatents

    Hsu, John S.; Adams, Donald J.; Su, Gui-Jia; Marlino, Laura D.; Ayers, Curtis W.; Coomer, Chester

    2005-08-16

    A cascaded die mounting device and method using spring contacts for die attachment, with or without metallic bonds between the contacts and the dies, is disclosed. One embodiment is for the direct refrigerant cooling of an inverter/converter carrying higher power levels than most of the low power circuits previously taught, and does not require using a heat sink.

  10. Analysis of radiology business models.

    PubMed

    Enzmann, Dieter R; Schomer, Donald F

    2013-03-01

    As health care moves to value orientation, radiology's traditional business model faces challenges to adapt. The authors describe a strategic value framework that radiology practices can use to best position themselves in their environments. This simplified construct encourages practices to define their dominant value propositions. There are 3 main value propositions that form a conceptual triangle, whose vertices represent the low-cost provider, the product leader, and the customer intimacy models. Each vertex has been a valid market position, but each demands specific capabilities and trade-offs. The underlying concepts help practices select value propositions they can successfully deliver in their competitive environments. Copyright © 2013 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. Comparison of surface modified zirconia implants with commercially available zirconium and titanium implants: a histological study in pigs.

    PubMed

    Gredes, Tomasz; Kubasiewicz-Ross, Pawel; Gedrange, Tomasz; Dominiak, Marzena; Kunert-Keil, Christiane

    2014-08-01

    New biomaterials and their various surface modifications should undergo in vitro and in vivo evaluation before clinical trials. The objective of our in vivo study was to evaluate the biocompatibility of newly created zirconium implant surfaces after implantation in the lower jaw of pigs and compare the osseointegration of these dental implants with commercially available zirconium and titanium implants. After a healing period of 12 weeks, a histological analysis of the soft and hard tissues and a histomorphometric analysis of the bone-implant contact (BIC) were performed. The implant surfaces showed an intimate connection to the adjacent bone for all tested implants. The 3 newly created zirconium implant surfaces achieved a BIC of 45% on average in comparison with a BIC of 56% from the reference zirconium implants and 35% from titanium implants. Furthermore, the new zirconium implants had a better attachment to gingival and bone tissues in the range of implant necks as compared with the reference implants. The results suggest that the new implants comparably osseointegrate within the healing period, and they have a good in vivo biocompatibility.

  12. Machining of Silicon-Ribbon-Forming Dies

    NASA Technical Reports Server (NTRS)

    Menna, A. A.

    1985-01-01

    Carbon extension for dies used in forming silicon ribbon crystals machined precisely with help of special tool. Die extension has edges beveled toward narrow flats at top, with slot precisely oriented and centered between flats and bevels. Cutting tool assembled from standard angle cutter and circular saw or saws. Angle cutters cuts bevels while slot saw cuts slot between them. In alternative version, custom-ground edges or additional circular saws also cut flats simultaneously.

  13. Use of a simulation laboratory to train radiology residents in the management of acute radiologic emergencies.

    PubMed

    Sarwani, Nabeel; Tappouni, Rafel; Flemming, Donald

    2012-08-01

    Simulation laboratories use realistic clinical scenarios to train physicians in a controlled environment, especially in potentially life-threatening complications that require prompt management. The objective of our study was to develop a comprehensive program using the simulation laboratory to train radiology residents in the management of acute radiologic emergencies. All radiology residents attended a dedicated simulation laboratory course lasting 3 hours, divided over two sessions. Training included basic patient management skills, management of a tension pneumothorax, massive hemorrhage, and contrast agent reactions. Participants were presented with 20 multiple-choice questions before and after the course. Pre- and posttest results were analyzed, and the McNemar test was used to compare correct responses by individual question. Twenty-six radiology residents attended the class. The average pre- and posttest scores and the average difference between the scores for all residents were 13.8, 17.1, and 3.3, respectively (p < 0.0001). Incorrect answers on the pretest examination that were subsequently answered correctly concerned administration of epinephrine for severe reactions, management of a tension pneumothorax, oxygen therapy, ECG placement, cardiopulmonary resuscitation technique, and where to stand during a code situation. Persistent incorrect answers concerned vasovagal reactions and emergency telephone numbers at an off-site imaging center. Simulation laboratories can be used to teach crisis management and crisis resource management for radiology residents and should be part of the education toolbox. Defined objectives lead to a comprehensive course dealing with the management of acute radiologic emergencies. Such programs can improve the role of radiologists as members of the health care team.

  14. Diagnostic Principles of Peri-Implantitis: a Systematic Review and Guidelines for Peri-Implantitis Diagnosis Proposal.

    PubMed

    Ramanauskaite, Ausra; Juodzbalys, Gintaras

    2016-01-01

    To review and summarize the literature concerning peri-implantitis diagnostic parameters and to propose guidelines for peri-implantitis diagnosis. An electronic literature search was conducted of the MEDLINE (Ovid) and EMBASE databases for articles published between 2011 and 2016. Sequential screening at the title/abstract and full-text levels was performed. Systematic reviews/guidelines of consensus conferences proposing classification or suggesting diagnostic parameters for peri-implantitis in the English language were included. The review was recorded on PROSPERO system with the code CRD42016033287. The search resulted in 10 articles that met the inclusion criteria. Four were papers from consensus conferences, two recommended diagnostic guidelines, three proposed classification of peri-implantitis, and one suggested an index for implant success. The following parameters were suggested to be used for peri-implantitis diagnosis: pain, mobility, bleeding on probing, probing depth, suppuration/exudate, and radiographic bone loss. In all of the papers, different definitions of peri-implantitis or implant success, as well as different thresholds for the above mentioned clinical and radiographical parameters, were used. Current evidence rationale for the diagnosis of peri-implantitis and classification based on consecutive evaluation of soft-tissue conditions and the amount of bone loss were suggested. Currently there is no single uniform definition of peri-implantitis or the parameters that should be used. Rationale for diagnosis and prognosis of peri-implantitis as well as classification of the disease is proposed.

  15. A prospective, split-mouth study comparing tilted implants with angulated connection versus conventional implants with angulated abutment.

    PubMed

    Van Weehaeghe, Manú; De Bruyn, Hugo; Vandeweghe, Stefan

    2017-12-01

    An angulation of the implant connection could overcome the problems related to angulated abutments. This study compares conventional implants with angulated abutment to tilted implants with an angulated connection. Twenty patients were treated in the edentulous mandible. In the posterior jaw locations, one conventional tilted implant with angulated abutment and one angulated implant without abutment were placed. In the anterior jaw, two conventional implants were placed, one with and one without abutment. Implants were immediately loaded and 3 months later, the final bridge (PFM or monolithic zirconia) was placed. After a follow-up of 48 months, 17 patients were available for clinical examination. The mean overall marginal bone loss (MBL) was 1.26 mm. No significant differences in implant survival, MBL, periodontal indices, patients' satisfaction, or complications was found between implants restored on abutment or implant level, between the posteriorly located angulated implant nor angulated abutment, and between both anterior implants with or without abutment. The posterior implants demonstrated less MBL compared to the anterior implants (P < .001). There was no significant difference in MBL between the implants restored with zirconia or PFM bridges (P = .294). Overall mean pocket depth was 2.83 mm. More plaque was found in the PFM group compared to the full-zirconia group, at the bridge (P = .042) and the implants (P = .029). There was no difference between both materials in pocket depth (P = .635) or bleeding (P = .821). One zirconia bridge fractured, two angulated abutment were replaced and four loose bridge screws connected to the angulated abutments had to be tightened. Patients were overall satisfied (4.74/5). An implant with angulated connection may results in a stronger connection but does not affect the marginal bone loss. No difference in MBL was seen between implants restored on abutment or implant level. Zirconia seems to reduce

  16. 25 CFR 301.3 - Specifications of dies.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Specifications of dies. 301.3 Section 301.3 Indians INDIAN ARTS AND CRAFTS BOARD, DEPARTMENT OF THE INTERIOR NAVAJO, PUEBLO, AND HOPI SILVER AND TURQUOISE... more mechanical than hand tools and vise. Dies shall contain only a single element of the design. ...

  17. A Comparative Study of Defibrillator Leads at a Large-Volume Implanting Hospital: Results From the Pacemaker and Implantable Defibrillator Leads Survival Study ("PAIDLESS").

    PubMed

    Cohen, Todd J; Asheld, Wilbur J; Germano, Joseph; Islam, Shahidul; Patel, Dhimesh

    2015-06-01

    The purpose of the study was to examine survival in the implantable defibrillator subset of implanted leads at a large-volume implanting hospital. Implantable lead survival has been the subject of many multicenter studies over the past decade. Fewer large implanting volume single-hospital studies have examined defibrillator lead failure as it relates to patient survival and lead construction. This investigator-initiated retrospective study examined defibrillator lead failure in those who underwent implantation of a defibrillator between February 1, 1996 and December 31, 2011. Lead failure was defined as: failure to capture/sense, abnormal pacing and/or defibrillator impedance, visual insulation defect or lead fracture, extracardiac stimulation, cardiac perforation, tricuspid valve entrapment, lead tip fracture and/or lead dislodgment. Patient characteristics, implant approach, lead manufacturers, lead models, recalled status, patient mortality, and core lead design elements were compared using methods that include Kaplan Meier analysis, univariate and multivariable Cox regression models. A total of 4078 defibrillator leads were implanted in 3802 patients (74% male; n = 2812) with a mean age of 70 ± 13 years at Winthrop University Hospital. Lead manufacturers included: Medtronic: [n = 1834; 801 recalled]; St. Jude Medical: [n = 1707; 703 recalled]; Boston Scientific: [n = 537; 0 recalled]. Kaplan-Meier analysis adjusted for multiple comparisons revealed that both Boston Scientific's and St. Jude Medical's leads had better survival than Medtronic's leads (P<.001 and P=.01, respectively). Lead survival was comparable between Boston Scientific and St. Jude Medical (P=.80). A total of 153 leads failed (3.5% of all leads) during the study. There were 99 lead failures from Medtronic (5.4% failure rate); 56 were recalled Sprint Fidelis leads. There were 36 lead failures from St. Jude (2.1% failure rate); 20 were recalled Riata or Riata ST leads. There were 18 lead

  18. Professional profile of radiologic technology educators.

    PubMed

    Legg, Jeffrey S; Pollard, Debra K; Fauber, Terri L

    2005-01-01

    Full-time radiologic technology educators (n = 565) were surveyed to determine their demographic characteristics and professional profile. Overall, the majority of radiologic technology educators surveyed were women between the ages of 40 and 59, had a bachelor's or master's degree, were certified in radiography and reported annual incomes from 40,001 dollars to 60,000 dollars. Most educators spent between 1 hour and 8 hours per week on classroom instruction/laboratory and in the clinical setting. Additionally, hospital or community college programs employed the majority of educators. Demographic characteristics of radiologic technology educators varied according to the type of institution in which they were employed and by education level. Study findings show a potential loss of qualified educators in the near future and the need for increased efforts to prepare and recruit radiologic technologists into the education career path.

  19. Apparatus for safeguarding a radiological source

    DOEpatents

    Bzorgi, Fariborz M

    2014-10-07

    A tamper detector is provided for safeguarding a radiological source that is moved into and out of a storage location through an access porthole for storage and use. The radiological source is presumed to have an associated shipping container approved by the U.S. Nuclear Regulatory Commission for transporting the radiological source. The tamper detector typically includes a network of sealed tubing that spans at least a portion of the access porthole. There is an opening in the network of sealed tubing that is large enough for passage therethrough of the radiological source and small enough to prevent passage therethrough of the associated shipping cask. Generally a gas source connector is provided for establishing a gas pressure in the network of sealed tubing, and a pressure drop sensor is provided for detecting a drop in the gas pressure below a preset value.

  20. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants.

    PubMed

    Ersoy, Ahmet Ersan; Turkyilmaz, Ilser; Ozan, Oguz; McGlumphy, Edwin A

    2008-08-01

    Dental implant placement requires precise planning with regard to anatomic limitations and restorative goals. The aim of this study was to evaluate the match between the positions and axes of the planned and placed implants using stereolithographic (SLA) surgical guides. Ninety-four implants were placed using SLA surgical guides generated from computed tomography (CT) between 2005 and 2006. Radiographic templates were used for all subjects during CT imaging. After obtaining three-dimensional CT images, each implant was virtually placed on the CT images. SLA surgical guides, fabricated using an SLA machine with a laser beam to polymerize the liquid photo-polymerized resin, were used during implant placement. A new CT scan was taken for each subject following implant placement. Special software was used to fuse the images of the planned and placed implants, and the locations and axes were compared. Compared to the planned implants, the placed implants showed angular deviation of 4.9 degrees+/-2.36 degrees, whereas the mean linear deviation was 1.22+/-0.85 mm at the implant neck and 1.51+/-1 mm at the implant apex. Compared to the implant planning, the angular deviation and linear deviation at the neck and apex of the placed maxillary implants were 5.31 degrees+/-0.36 degrees, 1.04+/-0.56 mm, and 1.57+/-0.97 mm, respectively, whereas corresponding figures for placed mandibular implants were 4.44 degrees+/-0.31 degrees, 1.42+/-1.05 mm, and 1.44+/-1.03 mm, respectively. SLA surgical guides using CT data may be reliable in implant placement and make flapless implant placement possible.