Sample records for routine clinical imaging

  1. Nonoperative management of blunt renal trauma: Is routine early follow-up imaging necessary?

    PubMed Central

    Malcolm, John B; Derweesh, Ithaar H; Mehrazin, Reza; DiBlasio, Christopher J; Vance, David D; Joshi, Salil; Wake, Robert W; Gold, Robert

    2008-01-01

    Background There is no consensus on the role of routine follow-up imaging during nonoperative management of blunt renal trauma. We reviewed our experience with nonoperative management of blunt renal injuries in order to evaluate the utility of routine early follow-up imaging. Methods We reviewed all cases of blunt renal injury admitted for nonoperative management at our institution between 1/2002 and 1/2006. Data were compiled from chart review, and clinical outcomes were correlated with CT imaging results. Results 207 patients were identified (210 renal units). American Association for the Surgery of Trauma (AAST) grades I, II, III, IV, and V were assigned to 35 (16%), 66 (31%), 81 (39%), 26 (13%), and 2 (1%) renal units, respectively. 177 (84%) renal units underwent routine follow-up imaging 24–48 hours after admission. In three cases of grade IV renal injury, a ureteral stent was placed after serial imaging demonstrated persistent extravasation. In no other cases did follow-up imaging independently alter clinical management. There were no urologic complications among cases for which follow-up imaging was not obtained. Conclusion Routine follow-up imaging is unnecessary for blunt renal injuries of grades I-III. Grade IV renovascular injuries can be followed clinically without routine early follow-up imaging, but urine extravasation necessitates serial imaging to guide management decisions. The volume of grade V renal injuries in this study is not sufficient to support or contest the need for routine follow-up imaging. PMID:18768088

  2. Limited utility of routine surveillance imaging for classical Hodgkin lymphoma patients in first complete remission.

    PubMed

    Pingali, Sai Ravi; Jewell, Sarah W; Havlat, Luiza; Bast, Martin A; Thompson, Jonathan R; Eastwood, Daniel C; Bartlett, Nancy L; Armitage, James O; Wagner-Johnston, Nina D; Vose, Julie M; Fenske, Timothy S

    2014-07-15

    The objective of this study was to compare the outcomes of patients with classical Hodgkin lymphoma (cHL) who achieved complete remission with frontline therapy and then underwent either clinical surveillance or routine surveillance imaging. In total, 241 patients who were newly diagnosed with cHL between January 2000 and December 2010 at 3 participating tertiary care centers and achieved complete remission after first-line therapy were retrospectively analyzed. Of these, there were 174 patients in the routine surveillance imaging group and 67 patients in the clinical surveillance group, based on the intended mode of surveillance. In the routine surveillance imaging group, the intended plan of surveillance included computed tomography and/or positron emission tomography scans; whereas, in the clinical surveillance group, the intended plan of surveillance was clinical examination and laboratory studies, and scans were obtained only to evaluate concerning signs or symptoms. Baseline patient characteristics, prognostic features, treatment records, and outcomes were collected. The primary objective was to compare overall survival for patients in both groups. For secondary objectives, we compared the success of second-line therapy and estimated the costs of imaging for each group. After 5 years of follow-up, the overall survival rate was 97% (95% confidence interval, 92%-99%) in the routine surveillance imaging group and 96% (95% confidence interval, 87%-99%) in the clinical surveillance group (P = .41). There were few relapses in each group, and all patients who relapsed in both groups achieved complete remission with second-line therapy. The charges associated with routine surveillance imaging were significantly higher than those for the clinical surveillance strategy, with no apparent clinical benefit. Clinical surveillance was not inferior to routine surveillance imaging in patients with cHL who achieved complete remission with frontline therapy. Routine

  3. Practical Considerations for Clinical PET/MR Imaging.

    PubMed

    Galgano, Samuel; Viets, Zachary; Fowler, Kathryn; Gore, Lael; Thomas, John V; McNamara, Michelle; McConathy, Jonathan

    2018-01-01

    Clinical PET/MR imaging is currently performed at a number of centers around the world as part of routine standard of care. This article focuses on issues and considerations for a clinical PET/MR imaging program, focusing on routine standard-of-care studies. Although local factors influence how clinical PET/MR imaging is implemented, the approaches and considerations described here intend to apply to most clinical programs. PET/MR imaging provides many more options than PET/computed tomography with diagnostic advantages for certain clinical applications but with added complexity. A recurring theme is matching the PET/MR imaging protocol to the clinical application to balance diagnostic accuracy with efficiency. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Practical Considerations for Clinical PET/MR Imaging.

    PubMed

    Galgano, Samuel; Viets, Zachary; Fowler, Kathryn; Gore, Lael; Thomas, John V; McNamara, Michelle; McConathy, Jonathan

    2017-05-01

    Clinical PET/MR imaging is currently performed at a number of centers around the world as part of routine standard of care. This article focuses on issues and considerations for a clinical PET/MR imaging program, focusing on routine standard-of-care studies. Although local factors influence how clinical PET/MR imaging is implemented, the approaches and considerations described here intend to apply to most clinical programs. PET/MR imaging provides many more options than PET/computed tomography with diagnostic advantages for certain clinical applications but with added complexity. A recurring theme is matching the PET/MR imaging protocol to the clinical application to balance diagnostic accuracy with efficiency. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Medical imaging: examples of clinical applications

    NASA Astrophysics Data System (ADS)

    Meinzer, H. P.; Thorn, M.; Vetter, M.; Hassenpflug, P.; Hastenteufel, M.; Wolf, I.

    Clinical routine is currently producing a multitude of diagnostic digital images but only a few are used in therapy planning and treatment. Medical imaging is involved in both diagnosis and therapy. Using a computer, existing 2D images can be transformed into interactive 3D volumes and results from different modalities can be merged. Furthermore, it is possible to calculate functional areas that were not visible in the primary images. This paper presents examples of clinical applications that are integrated into clinical routine and are based on medical imaging fundamentals. In liver surgery, the importance of virtual planning is increasing because surgery is still the only possible curative procedure. Visualisation and analysis of heart defects are also gaining in significance due to improved surgery techniques. Finally, an outlook is provided on future developments in medical imaging using navigation to support the surgeon's work. The paper intends to give an impression of the wide range of medical imaging that goes beyond the mere calculation of medical images.

  6. Diagnostic yield of a routine magnetic resonance imaging in tinnitus and clinical relevance of the anterior inferior cerebellar artery loops.

    PubMed

    Hoekstra, Carlijn E L; Prijs, Vera F; van Zanten, Gijsbert A

    2015-02-01

    To assess the diagnostic yield of a routine magnetic resonance imaging (MRI) scan in patients with (unilateral) chronic tinnitus, to define the frequency of incidental findings, and to assess the clinical relevance of potentially found anterior inferior cerebellar artery (AICA) loops. Retrospective cohort study. Tertiary Tinnitus Care Group at the University Medical Center Utrecht. Three hundred twenty-one patients with chronic tinnitus. Routine diagnostic magnetic resonance imaging (MRI) and diagnostic auditory brainstem responses (ABR) when an AICA loop was found. Relationship between abnormalities on MRI and tinnitus. In 138 patients (45%), an abnormality on the MRI scan was described. In only 7 patients (2.2%), the abnormality probably related to the patient's tinnitus. Results were not significantly better in patients with unilateral tinnitus (abnormalities in 3.2%). Incidental findings, not related to the tinnitus, were found in 41% of the patients. In 70 patients (23%), an AICA loop was found in the internal auditory canal. No significant relationships were found between the presence of an AICA loop and the side of the tinnitus, abnormalities on the ABR or complaints specific to nerve compression syndrome. A routine MRI is of little or no value in patients with tinnitus with persistent complaints. Anterior inferior cerebellar artery loops are often encountered on an MRI scan but rarely relate to the tinnitus and should thus be considered incidental findings. It is advised to only perform an MRI when on clinical grounds a specific etiology with tinnitus as the symptom seems probable.

  7. Toshiba General Hospital PACS for routine in- and outpatient clinics

    NASA Astrophysics Data System (ADS)

    Toshimitsu, Akihiro; Okazaki, Nobuo; Kura, Hiroyuki; Nishihara, Eitaro; Tsubura, Shinichi

    1996-05-01

    The Toshiba General Hospital introduced a departmental RIS/PACS (Radiology Information System/Picture Archiving and Communication System) in the radiology department in May, 1993. It has been used routinely since that time. In order to provide efficient means for clinicians to find and read many images, the system has been expanded to the neurosurgery and urology clinics and wards since May, 1995, and five image referring workstations now provide digital images to clinicians. In this paper we discuss an algorithm for image migration, one of the key issues to accomplish the expansion to outpatient clinics successfully, and propose the WYWIWYG (what you want is what you get) image transfer logic. This is the logic used to transfer images that physicians require refer without increasing the traffic between the image server and referring workstations. We accomplish the WYWIWYG logic by prioritizing exams the physicians have not yet viewed and by finding historical exams according to the modality, anatomy, and marking. Clinicians gave us comments from their first use of the system and suggested that the PACS enables clinicians to review images more efficiently compared to a film-based system. Our experience suggests that it is a key to the effective application of PACS in outpatient clinics to incorporate consideration patterns of clinicians on the migration algorithm.

  8. Time lapse imaging: is it time to incorporate this technology into routine clinical practice?

    PubMed

    Bhide, Priya; Maheshwari, Abha; Cutting, Rachel; Seenan, Susan; Patel, Anita; Khan, Khalid; Homburg, Roy

    2017-06-01

    Time-lapse imaging (TLI) systems for embryo incubation, assessment and selection are a novel technology available to in vitro fertilization (IVF) clinics. However, there is uncertainty about their clinical and cost-effectiveness and insufficient good quality evidence to warrant their routine use. Despite this, enthusiastic commercial marketing and slipping clinical equipoise have led to the widespread hasty introduction of this technology into practice, often at a considerable expense to the patient. We have reviewed the published literature and aim to summarize the strengths, weaknesses, opportunities and threats of these systems. These specialized incubators provide undisturbed embryo culture conditions and, by almost continuous monitoring of embryo development, generate morphokinetic parameters to aid embryo selection. They are thus hypothesized to improve outcomes following IVF. Although literature reports improved reproductive outcomes, these outcomes are largely surrogate and there is a paucity of studies reporting live births. The use of time lapse systems may reduce early pregnancy loss, increase elective single embryo transfers and limit multiple pregnancies through better embryo selection. However, the quality of the studies and hence the evidence so far, is low to moderate quality. We recommend further research producing robust high-quality evidence for and against the use of these systems.

  9. Investigation of Factors Affecting Body Temperature Changes During Routine Clinical Head Magnetic Resonance Imaging

    PubMed Central

    Kim, Myeong Seong

    2016-01-01

    Background Pulsed radiofrequency (RF) magnetic fields, required to produce magnetic resonance imaging (MRI) signals from tissue during the MRI procedure have been shown to heat tissues. Objectives To investigate the relationship between body temperature rise and the RF power deposited during routine clinical MRI procedures, and to determine the correlation between this effect and the body’s physiological response. Patients and Methods We investigated 69 patients from the Korean national cancer center to identify the main factors that contribute to an increase in body temperature (external factors and the body’s response) during a clinical brain MRI. A routine protocol sequence of MRI scans (1.5 T and 3.0 T) was performed. The patient’s tympanic temperature was recorded before and immediately after the MRI procedure and compared with changes in variables related to the body’s physiological response to heat. Results Our investigation of the physiological response to RF heating indicated a link between increasing age and body temperature. A higher increase in body temperature was observed in older patients after a 3.0-T MRI (r = 0.07, P = 0.29 for 1.5-T MRI; r = 0.45, P = 0.002 for 3.0-T MRI). The relationship between age and body heat was related to the heart rate (HR) and changes in HR during the MRI procedure; a higher RF power combined with a reduction in HR resulted in an increase in body temperature. Conclusion A higher magnetic field strength and a decrease in the HR resulted in an increase in body temperature during the MRI procedure. PMID:27895872

  10. Subthalamic Nucleus Visualization on Routine Clinical Preoperative MRI Scans: A Retrospective Study of Clinical and Image Characteristics Predicting Its Visualization.

    PubMed

    Ranjan, Manish; Boutet, Alexandre; Xu, David S; Lozano, Christopher S; Kumar, Rajeev; Fasano, Alfonso; Kucharczyk, Walter; Lozano, Andres M

    2018-05-30

    The visualization of the subthalamic nucleus (STN) on magnetic resonance imaging (MRI) is variable. Studies of the contribution of patient-related factors and intrinsic brain volumetrics to STN visualization have not been reported previously. To assess the visualization of the STN during deep brain stimulation (DBS) surgery in a clinical setting. Eighty-two patients undergoing pre-operative MRI to plan for STN DBS for Parkinson disease were retrospectively studied. The visualization of the STN and its borders was assessed and scored by 3 independent observers using a 4-point ordinal scale (from 0 = not seen to 3 = excellent visualization). This measure was then correlated with the patients' clinical information and brain volumes. The mean STN visualization scores were 1.68 and 1.63 for the right and left STN, respectively, with a good interobserver reliability (intraclass correlation coefficient: 0.744). Older age and decreased white matter volume were negatively correlated with STN visualization (p < 0.05). STN visualization is only fair to good on routine MRI with good concordance of interindividual rating. Advancing age and decreased white matter are associated with poor visualization of the STN. Knowledge about factors contributing to poor visualization of the STN could alert a surgeon to modify the imaging strategy to optimize surgical targeting. © 2018 S. Karger AG, Basel.

  11. Quantitative CT characterization of pediatric lung development using routine clinical imaging

    PubMed Central

    Stein, Jill M.; Walkup, Laura L.; Brody, Alan S.; Fleck, Robert J.

    2016-01-01

    Background The use of quantitative CT analysis in children is limited by lack of normal values of lung parenchymal attenuation. These characteristics are important because normal lung development yields significant parenchymal attenuation changes as children age. Objective To perform quantitative characterization of normal pediatric lung parenchymal X-ray CT attenuation under routine clinical conditions in order to establish a baseline comparison to that seen in pathological lung conditions. Materials and methods We conducted a retrospective query of normal CT chest examinations in children ages 0–7 years from 2004 to 2014 using standard clinical protocol. During these examinations semi-automated lung parenchymal segmentation was performed to measure lung volume and mean lung attenuation. Results We analyzed 42 CT examinations in 39 children, ages 3 days to 83 months (mean ± standard deviation [SD] = 42±27 months). Lung volume ranged 0.10–1.72 liters (L). Mean lung attenuation was much higher in children younger than 12 months, with values as high as −380 Hounsfield units (HU) in neonates (lung volume 0.10 L). Lung volume decreased to approximately −650 HU by age 2 years (lung volume 0.47 L), with subsequently slower exponential decrease toward a relatively constant value of −860 HU as age and lung volume increased. Conclusion Normal lung parenchymal X-ray CT attenuation decreases with increasing lung volume and age; lung attenuation decreases rapidly in the first 2 years of age and more slowly thereafter. This change in normal lung attenuation should be taken into account as quantitative CT methods are translated to pediatric pulmonary imaging. PMID:27576458

  12. Effect of Routine Surveillance Imaging on the Outcomes of Patients With Classical Hodgkin Lymphoma After Autologous Hematopoietic Cell Transplantation.

    PubMed

    Kapke, Jonathan T; Epperla, Narendranath; Shah, Namrata; Richardson, Kristin; Carrum, George; Hari, Parameswaran N; Pingali, Sai R; Hamadani, Mehdi; Karmali, Reem; Fenske, Timothy S

    2017-07-01

    Patients with relapsed and refractory classical Hodgkin lymphoma (cHL) are often treated with autologous hematopoietic cell transplantation (auto-HCT). After auto-HCT, most transplant centers implement routine surveillance imaging to monitor for disease relapse; however, there is limited evidence to support this practice. In this multicenter, retrospective study, we identified cHL patients (n = 128) who received auto-HCT, achieved complete remission (CR) after transplantation, and then were followed with routine surveillance imaging. Of these, 29 (23%) relapsed after day 100 after auto-HCT. Relapse was detected clinically in 14 patients and with routine surveillance imaging in 15 patients. When clinically detected relapse was compared with to radiographically detected relapse respectively, the median overall survival (2084 days [range, 225-4161] vs. 2737 days [range, 172-2750]; P = .51), the median time to relapse (247 days [range, 141-3974] vs. 814 days [range, 96-1682]; P = .30) and the median postrelapse survival (674 days [range, 13-1883] vs. 1146 days [range, 4-2548]; P = .52) were not statistically different. In patients who never relapsed after auto-HCT, a median of 4 (range, 1-25) surveillance imaging studies were performed over a median follow-up period of 3.5 years. A minority of patients with cHL who achieve CR after auto-HCT will ultimately relapse. Surveillance imaging detected approximately half of relapses; however, outcomes were similar for those whose relapse was detected using routine surveillance imaging versus detected clinically in between surveillance imaging studies. There appears to be limited utility for routine surveillance imaging in cHL patients who achieve CR after auto-HCT. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Utility of Routine Outpatient Cervical Spine Imaging Following Anterior Cervical Corpectomy and Fusion.

    PubMed

    Desai, Atman; Pendharkar, Arjun V; Swienckowski, Jessica G; Ball, Perry A; Lollis, Scott; Simmons, Nathan E

    2015-11-23

    Construct failure is an uncommon but well-recognized complication following anterior cervical corpectomy and fusion (ACCF). In order to screen for these complications, many centers routinely image patients at outpatient visits following surgery. There remains, however, little data on the utility of such imaging. The electronic medical record of all patients undergoing anterior cervical corpectomy and fusion at Dartmouth-Hitchcock Medical Center between 2004 and 2009 were reviewed. All patients had routine cervical spine radiographs performed perioperatively. Follow-up visits up to two years postoperatively were analyzed.  Sixty-five patients (mean age 52.2) underwent surgery during the time period. Eighteen patients were female. Forty patients had surgery performed for spondylosis, 20 for trauma, three for tumor, and two for infection. Forty-three patients underwent one-level corpectomy, 20 underwent two-level corpectomy, and two underwent three-level corpectomy, using an allograft, autograft, or both. Sixty-two of the fusions were instrumented using a plate and 13 had posterior augmentation. Fifty-seven patients had follow-up with imaging at four to 12 weeks following surgery, 54 with plain radiographs, two with CT scans, and one with an MRI scan. Unexpected findings were noted in six cases. One of those patients, found to have asymptomatic recurrent kyphosis following a two-level corpectomy, had repeat surgery because of those findings. Only one further patient was found to have abnormal imaging up to two years, and this patient required no further intervention. Routine imaging after ACCF can demonstrate asymptomatic occurrences of clinically significant instrument failure. In 43 consecutive single-level ACCF however, routine imaging did not change management, even when an abnormality was discovered. This may suggest a limited role for routine imaging after ACCF in longer constructs involving multiple levels.

  14. Impact of Routine Surveillance Imaging on Outcomes of Patients With Diffuse Large B-Cell Lymphoma After Autologous Hematopoietic Cell Transplantation.

    PubMed

    Epperla, Narendranath; Shah, Namrata; Hamadani, Mehdi; Richardson, Kristin; Kapke, Jonathan T; Patel, Asmita; Teegavarapu, Sravanthi P; Carrum, George; Hari, Parameswaran N; Pingali, Sai R; Karmali, Reem; Fenske, Timothy S

    2016-12-01

    For patients with relapsed or refractory diffuse large B-cell lymphoma (DLBCL), autologous hematopoietic cell transplantation (auto-HCT) is commonly used. After auto-HCT, DLBCL patients are often monitored with surveillance imaging. However, there is little evidence to support this practice. We performed a multicenter retrospective study of DLBCL patients who underwent auto-HCT (n = 160), who experienced complete remission after transplantation, and who then underwent surveillance imaging. Of these, only 45 patients experienced relapse after day +100 after auto-HCT, with relapse detected by routine imaging in 32 (71%) and relapse detected clinically in 13 (29%). Baseline patient characteristics were similar between the 2 groups. Comparing the radiographic and clinically detected relapse groups, the median time from diagnosis to auto-HCT (389 days vs. 621 days, P = .06) and the median follow-up after auto-HCT (2464 days vs. 1593 days P = .60) were similar. The median time to relapse after auto-HCT was 191 days in radiographically detected relapses compared to 492 days in clinically detected relapses (P = .35), and median postrelapse survival was 359 days in such patients compared to 123 days in patients with clinically detected relapse (P = .36). However, the median posttransplantation overall survival was not significantly different for patients with relapse detected by routine imaging versus relapse detected clinically (643 vs. 586 days, P = .68). A majority (71%) of DLBCL relapses after auto-HCT are detected by routine surveillance imaging. Overall, there appears to be limited utility for routine imaging after auto-HCT except in select cases where earlier detection and salvage therapy with allogeneic HCT is a potential option. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Routine Cross-Sectional Head Imaging Before Electroconvulsive Therapy: A Tertiary Center Experience.

    PubMed

    Sajedi, Payam I; Mitchell, Jason; Herskovits, Edward H; Raghavan, Prashant

    2016-04-01

    Electroconvulsive therapy (ECT) is generally contraindicated in patients with intracranial mass lesions or in the presence of increased intracranial pressure. The purpose of this study was to determine the prevalence of incidental abnormalities on routine cross-sectional head imaging, including CT and MRI, that would preclude subsequent ECT. This retrospective study involved a review of the electronic medical records of 105 patients (totaling 108 imaging studies) between April 27, 2007, and March 20, 2015, referred for cranial CT or MRI with the primary indication of pre-ECT evaluation. The probability of occurrence of imaging findings that would preclude ECT was computed. A cost analysis was also performed on the practice of routine pre-ECT imaging. Of the 105 patients who presented with the primary indication of ECT clearance (totaling 108 scans), 1 scan (0.93%) revealed findings that precluded ECT. None of the studies demonstrated findings that indicated increased intracranial pressure. A cost analysis revealed that at least $18,662.70 and 521.97 relative value units must be expended to identify one patient with intracranial pathology precluding ECT. The findings of this study demonstrate an extremely low prevalence of findings that preclude ECT on routine cross-sectional head imaging. The costs incurred in identifying a potential contraindication are high. The authors suggest that the performance of pre-ECT neuroimaging be driven by the clinical examination. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Incorporating prognostic imaging biomarkers into clinical practice

    PubMed Central

    Miles, Kenneth A.

    2013-01-01

    Abstract A prognostic imaging biomarker can be defined as an imaging characteristic that is objectively measurable and provides information on the likely outcome of the cancer disease in an untreated individual and should be distinguished from predictive imaging biomarkers and imaging markers of response. A range of tumour characteristics of potential prognostic value can be measured using a variety imaging modalities. However, none has currently been adopted into routine clinical practice. This article considers key examples of emerging prognostic imaging biomarkers and proposes an evaluation framework that aims to demonstrate clinical efficacy and so support their introduction into the clinical arena. With appropriate validation within an established evaluation framework, prognostic imaging biomarkers have the potential to contribute to individualized cancer care, in some cases reducing the financial burden of expensive cancer treatments by facilitating their more rational use. PMID:24060808

  17. Imaging tests in staging and surveillance of non-metastatic breast cancer: changes in routine clinical practice and cost implications.

    PubMed

    De Placido, S; De Angelis, C; Giuliano, M; Pizzi, C; Ruocco, R; Perrone, V; Bruzzese, D; Tommasielli, G; De Laurentiis, M; Cammarota, S; Arpino, G; Arpino, G

    2017-03-14

    Although guidelines do not recommend computerised tomography (CT), positron emission tomography (PET) or magnetic resonance imaging (MRI) for the staging or follow-up of asymptomatic patients with non-metastatic breast cancer, they are often requested in routine clinical practice. The aim of this study was to determine the staging and follow-up patterns, and relative costs in a large population of breast cancer patients living and treated in a Southern Italian region. We analysed the clinical computerised information recorded by 567 primary-care physicians assisting about 650 000 inhabitants in the Campania region. Patients with non-metastatic breast cancer were identified and divided into calendar years from 2001 to 2010. The number of diagnostic tests prescribed per 100 patients (N/Pts) and the mean cost per patient was determined 3 months before diagnosis and up to 1 year after diagnosis. Costs are expressed in constant 2011 euros. We identified 4680 newly diagnosed cases of asymptomatic non-metastatic breast cancer. N/Pts increased significantly (P<0.0001) from 2001 to 2010. The mean number of prescribed mammograms, bone scans, abdominal ultrasound and chest X-rays ('routine tests'), and costs was unchanged. However, the number of CT, PET scans and MRI ('new tests')prescriptions almost quadrupled and the mean cost per patient related to these procedures significantly increased from [euro ]357 in 2001 to [euro ]830 in 2010 (P<0.0001). New test prescriptions and relative costs significantly and steadily increased throughout the study period. At present there is no evidence that the delivery of new tests to asymptomatic patients improves breast cancer outcome. Well-designed clinical trials are urgently needed to shed light on the impact of these tests on clinical outcome and overall survival.

  18. Cost-effectiveness of routine imaging of suspected appendicitis.

    PubMed

    D'Souza, N; Marsden, M; Bottomley, S; Nagarajah, N; Scutt, F; Toh, S

    2018-01-01

    Introduction The misdiagnosis of appendicitis and consequent removal of a normal appendix occurs in one in five patients in the UK. On the contrary, in healthcare systems with routine cross-sectional imaging of suspected appendicitis, the negative appendicectomy rate is around 5%. If we could reduce the rate in the UK to similar numbers, would this be cost effective? This study aimed to calculate the financial impact of negative appendicectomy at the Queen Alexandra Hospital and to explore whether a policy of routine imaging of such patients could reduce hospital costs. Materials and methods We performed a retrospective analysis of all appendicectomies over a 1-year period at our institution. Data were extracted on outcomes including appendix histology, operative time and length of stay to calculate the negative appendicectomy rate and to analyse costs. Results A total of 531 patients over 5 years of age had an appendicectomy. The negative appendicectomy rate was 22% (115/531). The additional financial costs of negative appendicectomy to the hospital during this period were £270,861. Universal imaging of all patients with right iliac fossa pain that could result in a 5% negative appendicectomy rate would cost between £67,200 and £165,600 per year but could save £33,896 (magnetic resonance imaging), £105,896 (computed tomography) or £132,296 (ultrasound) depending on imaging modality used. Conclusions Negative appendicectomy is still too frequent and results in additional financial burden to the health service. Routine imaging of patients with suspected appendicitis would not only reduce the negative appendicectomy rate but could lead to cost savings and a better service for our patients.

  19. Screening Breast MRI Outcomes in Routine Clinical Practice: Comparison to BI-RADS Benchmarks.

    PubMed

    Strigel, Roberta M; Rollenhagen, Jennifer; Burnside, Elizabeth S; Elezaby, Mai; Fowler, Amy M; Kelcz, Frederick; Salkowski, Lonie; DeMartini, Wendy B

    2017-04-01

    The BI-RADS Atlas 5th Edition includes screening breast magnetic resonance imaging (MRI) outcome benchmarks. However, the metrics are from expert practices and clinical trials of women with hereditary breast cancer predispositions, and it is unknown if they are appropriate for routine practice. We evaluated screening breast MRI audit outcomes in routine practice across a spectrum of elevated risk patients. This Institutional Review Board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study included all consecutive screening breast MRI examinations from July 1, 2010 to June 30, 2013. Examination indications were categorized as gene mutation carrier (GMC), personal history (PH) breast cancer, family history (FH) breast cancer, chest radiation, and atypia/lobular carcinoma in situ (LCIS). Outcomes were determined by pathology and/or ≥12 months clinical and/or imaging follow-up. We calculated abnormal interpretation rate (AIR), cancer detection rate (CDR), positive predictive value of recommendation for tissue diagnosis (PPV2) and biopsy performed (PPV3), and median size and percentage of node-negative invasive cancers. Eight hundred and sixty examinations were performed in 566 patients with a mean age of 47 years. Indications were 367 of 860 (42.7%) FH, 365 of 860 (42.4%) PH, 106 of 860 (12.3%) GMC, 14 of 860 (1.6%) chest radiation, and 8 of 22 (0.9%) atypia/LCIS. The AIR was 134 of 860 (15.6%). Nineteen cancers were identified (13 invasive, 4 DCIS, two lymph nodes), resulting in CDR of 19 of 860 (22.1 per 1000), PPV2 of 19 of 88 (21.6%), and PPV3 of 19 of 80 (23.8%). Of 13 invasive breast cancers, median size was 10 mm, and 8 of 13 were node negative (61.5%). Performance outcomes of screening breast MRI in routine clinical practice across a spectrum of elevated risk patients met the American College of Radiology Breast Imaging Reporting and Data System benchmarks, supporting broad application of these metrics. The indication

  20. Screening Breast MRI Outcomes in Routine Clinical Practice: Comparison to BI-RADS Benchmarks

    PubMed Central

    Strigel, Roberta M.; Rollenhagen, Jennifer; Burnside, Elizabeth S.; Elezaby, Mai; Fowler, Amy M.; Kelcz, Frederick; Salkowski, Lonie; DeMartini, Wendy B.

    2017-01-01

    Rationale and Objectives The BI-RADS Atlas 5th Edition includes screening breast magnetic resonance imaging (MRI) outcome benchmarks. However, the metrics are from expert practices and clinical trials of women with hereditary breast cancer predispositions, and it is unknown if they are appropriate for routine practice. We evaluated screening breast MRI audit outcomes in routine practice across a spectrum of elevated risk patients. Materials and Methods This Institutional Review Board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study included all consecutive screening breast MRI examinations from July 1, 2010 to June 30, 2013. Examination indications were categorized as gene mutation carrier (GMC), personal history (PH) breast cancer, family history (FH) breast cancer, chest radiation, and atypia/lobular carcinoma in situ (LCIS). Outcomes were determined by pathology and/or ≥12 months clinical and/or imaging follow-up. We calculated abnormal interpretation rate (AIR), cancer detection rate (CDR), positive predictive value of recommendation for tissue diagnosis (PPV2) and biopsy performed (PPV3), and median size and percentage of node-negative invasive cancers. Results Eight hundred and sixty examinations were performed in 566 patients with a mean age of 47 years. Indications were 367 of 860 (42.7%) FH, 365 of 860 (42.4%) PH, 106 of 860 (12.3%) GMC, 14 of 860 (1.6%) chest radiation, and 8 of 22 (0.9%) atypia/LCIS. The AIR was 134 of 860 (15.6%). Nineteen cancers were identified (13 invasive, 4 DCIS, two lymph nodes), resulting in CDR of 19 of 860 (22.1 per 1000), PPV2 of 19 of 88 (21.6%), and PPV3 of 19 of 80 (23.8%). Of 13 invasive breast cancers, median size was 10 mm, and 8 of 13 were node negative (61.5%). Conclusions Performance outcomes of screening breast MRI in routine clinical practice across a spectrum of elevated risk patients met the American College of Radiology Breast Imaging Reporting and Data System

  1. Usefulness of 3-Tesla cardiac magnetic resonance imaging in the assessment of aortic stenosis severity in routine clinical practice.

    PubMed

    Levy, Franck; Iacuzio, Laura; Civaia, Filippo; Rusek, Stephane; Dommerc, Carine; Hugues, Nicolas; Alexandrescu, Clara; Dor, Vincent; Tribouilloy, Christophe; Dreyfus, Gilles

    2016-11-01

    Recently, 1.5-Tesla cardiac magnetic resonance imaging (CMR) was reported to provide a reliable alternative to transthoracic echocardiography (TTE) for the quantification of aortic stenosis (AS) severity. Few data are available using higher magnetic field strength MRI systems in this context. To evaluate the feasibility and reproducibility of the assessment of aortic valve area (AVA) using 3-Tesla CMR in routine clinical practice, and to assess concordance between TTE and CMR for the estimation of AS severity. Ninety-one consecutive patients (60 men; mean age 74±10years) with known AS documented by TTE were included prospectively in the study. All patients underwent comprehensive TTE and CMR examination, including AVA estimation using the TTE continuity equation (0.81±0.18cm 2 ), direct CMR planimetry (CMRp) (0.90±0.22cm 2 ) and CMR using Hakki's formula (CMRhk), a simplified Gorlin formula (0.70±0.19cm 2 ). Although significant agreement with TTE was found for CMRp (r=0.72) and CMRhk (r=0.66), CMRp slightly overestimated (bias=0.11±0.18cm 2 ) and CMRhk slightly underestimated (bias=-0.11±0.17cm 2 ) AVA compared with TTE. Inter- and intraobserver reproducibilities of CMR measurements were excellent (r=0.72 and r=0.74 for CMRp and r=0.88 and r=0.92 for peak aortic velocity, respectively). 3-Tesla CMR is a feasible, radiation-free, reproducible imaging modality for the estimation of severity of AS in routine practice, knowing that CMRp tends to overestimate AVA and CMRhk to underestimate AVA compared with TTE. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  2. Routine magnetic resonance imaging for idiopathic olfactory loss: a modeling-based economic evaluation.

    PubMed

    Rudmik, Luke; Smith, Kristine A; Soler, Zachary M; Schlosser, Rodney J; Smith, Timothy L

    2014-10-01

    Idiopathic olfactory loss is a common clinical scenario encountered by otolaryngologists. While trying to allocate limited health care resources appropriately, the decision to obtain a magnetic resonance imaging (MRI) scan to investigate for a rare intracranial abnormality can be difficult. To evaluate the cost-effectiveness of ordering routine MRI in patients with idiopathic olfactory loss. We performed a modeling-based economic evaluation with a time horizon of less than 1 year. Patients included in the analysis had idiopathic olfactory loss defined by no preceding viral illness or head trauma and negative findings of a physical examination and nasal endoscopy. Routine MRI vs no-imaging strategies. We developed a decision tree economic model from the societal perspective. Effectiveness, probability, and cost data were obtained from the published literature. Litigation rates and costs related to a missed diagnosis were obtained from the Physicians Insurers Association of America. A univariate threshold analysis and multivariate probabilistic sensitivity analysis were performed to quantify the degree of certainty in the economic conclusion of the reference case. The comparative groups included those who underwent routine MRI of the brain with contrast alone and those who underwent no brain imaging. The primary outcome was the cost per correct diagnosis of idiopathic olfactory loss. The mean (SD) cost for the MRI strategy totaled $2400.00 ($1717.54) and was effective 100% of the time, whereas the mean (SD) cost for the no-imaging strategy totaled $86.61 ($107.40) and was effective 98% of the time. The incremental cost-effectiveness ratio for the MRI strategy compared with the no-imaging strategy was $115 669.50, which is higher than most acceptable willingness-to-pay thresholds. The threshold analysis demonstrated that when the probability of having a treatable intracranial disease process reached 7.9%, the incremental cost-effectiveness ratio for MRI vs no

  3. Effect of routine diagnostic imaging for patients with musculoskeletal disorders: A meta-analysis.

    PubMed

    Karel, Yasmaine H J M; Verkerk, Karin; Endenburg, Silvio; Metselaar, Sven; Verhagen, Arianne P

    2015-10-01

    The increasing use of diagnostic imaging has led to high expenditures, unnecessary invasive procedures and/or false-positive diagnoses, without certainty that the patients actually benefit from these imaging procedures. This review explores whether diagnostic imaging leads to better patient-reported outcomes in individuals with musculoskeletal disorders. Databases were searched from inception to September 2013, together with scrutiny of selected bibliographies. Trials were eligible when: 1) a diagnostic imaging procedure was compared with any control group not getting or not receiving the results of imaging; 2) the population included individuals suffering from musculoskeletal disorders, and 3) if patient-reported outcomes were available. Primary outcome measures were pain and function. Secondary outcome measures were satisfaction and quality of life. Subgroup analysis was done for different musculoskeletal complaints and high technological medical imaging (MRI/CT). Eleven trials were eligible. The effects of diagnostic imaging were only evaluated in patients with low back pain (n=7) and knee complaints (n=4). Overall, there was a moderate level of evidence for no benefit of diagnostic imaging on all outcomes compared with controls. A significant but clinically irrelevant effect was found in favor of no (routine) imaging in low back pain patients in terms of pain severity at short [SMD 0.17 (0.04-0.31)] and long-term follow-up [SMD 0.13 (0.02-0.24)], and for overall improvement [RR 1.15 (1.03-1.28)]. Subgroup analysis did not significantly change these results. These results strengthen the available evidence that routine referral to diagnostic imaging by general practitioners for patients with knee and low back pain yields little to no benefit. Copyright © 2015 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  4. Quantitative Imaging in Cancer Clinical Trials

    PubMed Central

    Yankeelov, Thomas E.; Mankoff, David A.; Schwartz, Lawrence H.; Lieberman, Frank S.; Buatti, John M.; Mountz, James M.; Erickson, Bradley J.; Fennessy, Fiona M.M.; Huang, Wei; Kalpathy-Cramer, Jayashree; Wahl, Richard L.; Linden, Hannah M.; Kinahan, Paul; Zhao, Binsheng; Hylton, Nola M.; Gillies, Robert J.; Clarke, Laurence; Nordstrom, Robert; Rubin, Daniel L.

    2015-01-01

    As anti-cancer therapies designed to target specific molecular pathways have been developed, it has become critical to develop methods to assess the response induced by such agents. While traditional, anatomic CT and MRI exams are useful in many settings, there is increasing evidence that these methods cannot answer the fundamental biological and physiological questions essential for assessment and, eventually, prediction of treatment response in the clinical trial setting, especially in the critical period soon after treatment is initiated. To optimally apply advances in quantitative imaging methods to trials of targeted cancer therapy, new infrastructure improvements are needed that incorporate these emerging techniques into the settings where they are most likely to have impact. In this review, we first elucidate the needs for therapeutic response assessment in the era of molecularly targeted therapy and describe how quantitative imaging can most effectively provide scientifically and clinically relevant data. We then describe the tools and methods required to apply quantitative imaging and provide concrete examples of work making these advances practically available for routine application in clinical trials. We conclude by proposing strategies to surmount barriers to wider incorporation of these quantitative imaging methods into clinical trials and, eventually, clinical practice. Our goal is to encourage and guide the oncology community to deploy standardized quantitative imaging techniques in clinical trials to further personalize care for cancer patients, and to provide a more efficient path for the development of improved targeted therapies. PMID:26773162

  5. Yield of Routine Image-Guided Biopsy of Renal Mass Thermal Ablation Zones: 11-Year Experience.

    PubMed

    Wasnik, Ashish P; Higgins, Ellen J; Fox, Giovanna A; Caoili, Elaine M; Davenport, Matthew S

    2018-06-19

    To determine the yield of routine image-guided core biopsy of renal cell carcinoma (RCC) thermal ablation zones. Institutional review board approval was obtained for this Health Insurance Portability and Accountability Act-compliant quality improvement effort. Routine core biopsy of RCC ablation zones was performed 2 months postablation from July 2003 to December 2014. Routine nicotinamide adenine dinucleotide staining was performed by specialized genitourinary pathologists to assess cell viability. The original purpose of performing routine postablation biopsy was to verify, in addition to imaging, whether the mass was completely treated. Imaging was stratified as negative, indeterminate, or positive for viable malignancy. Histology was stratified as negative, indeterminate, positive, or nondiagnostic for viable malignancy. Histology results were compared to prebiopsy imaging findings. Routine ablation zone biopsy was performed after 50% (146/292) of index ablations (24 cryoablations, 122 radiofrequency ablations), and postablation imaging was performed more often with multiphasic computed tomography than magnetic resonance imaging (100 vs 46, p < 0.0001). When imaging was negative (n = 117), biopsy added no additional information (92% [n = 108] negative, 0.9% [n = 1] indeterminate, 7% [n = 8] nondiagnostic). When imaging was indeterminate (n = 19), 11% (n = 2) of biopsies had viable RCC and 89% (n = 17) were negative. When imaging was positive, biopsy detected viable neoplasm in only 10% (1/10) of cases; 80% (8/10) were negative and 10% (1/10) were nondiagnostic. Routine biopsy of renal ablation zones to validate postablation imaging results was not value-added and therefore was discontinued at the study institution. Copyright © 2018. Published by Elsevier Inc.

  6. Deformable image registration based automatic CT-to-CT contour propagation for head and neck adaptive radiotherapy in the routine clinical setting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumarasiri, Akila, E-mail: akumara1@hfhs.org; Siddiqui, Farzan; Liu, Chang

    2014-12-15

    Purpose: To evaluate the clinical potential of deformable image registration (DIR)-based automatic propagation of physician-drawn contours from a planning CT to midtreatment CT images for head and neck (H and N) adaptive radiotherapy. Methods: Ten H and N patients, each with a planning CT (CT1) and a subsequent CT (CT2) taken approximately 3–4 week into treatment, were considered retrospectively. Clinically relevant organs and targets were manually delineated by a radiation oncologist on both sets of images. Four commercial DIR algorithms, two B-spline-based and two Demons-based, were used to deform CT1 and the relevant contour sets onto corresponding CT2 images. Agreementmore » of the propagated contours with manually drawn contours on CT2 was visually rated by four radiation oncologists in a scale from 1 to 5, the volume overlap was quantified using Dice coefficients, and a distance analysis was done using center of mass (CoM) displacements and Hausdorff distances (HDs). Performance of these four commercial algorithms was validated using a parameter-optimized Elastix DIR algorithm. Results: All algorithms attained Dice coefficients of >0.85 for organs with clear boundaries and those with volumes >9 cm{sup 3}. Organs with volumes <3 cm{sup 3} and/or those with poorly defined boundaries showed Dice coefficients of ∼0.5–0.6. For the propagation of small organs (<3 cm{sup 3}), the B-spline-based algorithms showed higher mean Dice values (Dice = 0.60) than the Demons-based algorithms (Dice = 0.54). For the gross and planning target volumes, the respective mean Dice coefficients were 0.8 and 0.9. There was no statistically significant difference in the Dice coefficients, CoM, or HD among investigated DIR algorithms. The mean radiation oncologist visual scores of the four algorithms ranged from 3.2 to 3.8, which indicated that the quality of transferred contours was “clinically acceptable with minor modification or major modification in a small number of

  7. Very poor agreement between routine outpatient clinic office and ambulatory blood pressure: time to improve an old hospital outpatient clinic routine?

    PubMed

    Reinhard, Mark; Poulsen, Per L; Christensen, Kent L

    2016-12-01

    We investigated the agreement between elevated outpatient clinic office blood pressure (OC-OBP) as measured in the daily routine in our University Hospital Cardiology Outpatient Clinic and subsequent awake ambulatory blood pressure (AABP). In all patients referred for ambulatory blood pressure monitoring from our Cardiology Outpatient Clinic, we identified OC-OBP and changes in medication in the period from 1 January 2014 to 15 September 2015. The AABP was used as a reference measurement for the OC-OBP. A total of 183 patients were included in the study. Their mean age was 62.1±14.0 years and 49% were women. The mean systolic OC-OBP was 166.8±17.9 mmHg and the difference between the mean systolic OC-OBP and AABP was 28.0±19.5 mmHg (P<0.001) with 95% limits of agreement from -10.2 to +66.3 mmHg. The difference in mean systolic OC-OBP and AABP was 18.6±14.7 mmHg in patients less than 45 years (n=21), 24.8±18.2 mmHg in patients 45-74 years (n=121) and 42.3±18.5 mmHg in patients more than or equal to 75 years (n=41). In 32 (17%) of the patients, the antihypertensive treatment was intensified before the AABP, but in nine (28%) of these patients, the antihypertensive treatment was reduced again after the AABP because of low blood pressure. Routine OC-OBP in a busy cardiology clinic agrees poorly with AABP and may lead to unnecessary treatment and pharmacologically induced symptomatic hypotension, particularly in elderly patients. The results of this study urgently call for alternative solutions to routine OC-OBP in hospital outpatient clinics.

  8. An invertebrate embryologist's guide to routine processing of confocal images.

    PubMed

    von Dassow, George

    2014-01-01

    It is almost impossible to use a confocal microscope without encountering the need to transform the raw data through image processing. Adherence to a set of straightforward guidelines will help ensure that image manipulations are both credible and repeatable. Meanwhile, attention to optimal data collection parameters will greatly simplify image processing, not only for convenience but for quality and credibility as well. Here I describe how to conduct routine confocal image processing tasks, including creating 3D animations or stereo images, false coloring or merging channels, background suppression, and compressing movie files for display.

  9. Vascular access clinic results before and after implementing a multidisciplinary approach adding routine Doppler ultrasound.

    PubMed

    Aragoncillo Sauco, Inés; Ligero Ramos, José Manuel; Vega Martínez, Almudena; Morales Muñoz, Ángel Luis; Abad Estébanez, Soraya; Macías Carmona, Nicolás; Ruiz Chiriboga, Diego; García Pajares, Rosario; Cervera Bravo, Teresa; López-Gómez, Juan Manuel; Manzano Grossi, Soledad; Menéndez Sánchez, Elena; Río Gomez, Javier; García Prieto, Ana María; Linares Grávalos, Tania; Garcia Boyano, Fernando; Reparaz Asensio, Luis Manuel; Albalate Ramón, Marta; de Sequera Ortiz, Patricia; Gil Casares, Beatriz; Ampuero Mencía, Jara; Castellano, Sandra; Martín Pérez, Belén; Conty, José Luís Martín; Santos Garcia, Alba; Luño Fernandez, José

    2018-06-11

    A multidisciplinary approach and Doppler ultrasound (DU) assessment for the creation and maintenance of arteriovenous fistulas (AVF) for haemodialysis can improve prevalence and patency. The aim of this study was to analyse the impact of a new multidisciplinary vascular access (VA) clinic with routine DU. We analysed the VA clinic results from 2014 and 2015, before and after the implementation of a multidisciplinary team protocol (vascular surgeon/nephrologist) with routine DU in preoperative mapping and prevalent AVF. We analysed 345 and 364 patients from 2014 and 2015 respectively. The number of surgical interventions was similar in both periods (p=.289), with a trend towards an increase in preventive surgical repair of AVF in 2015 (17 vs. 29, p=.098). 155 vs. 169 new AVF were performed in 2014 and 2015, with a significantly lower primary failure rate in 2015 (26.4 vs. 15.3%, p=.015), and a non-significant increase in radiocephalic AVF, 25.8 vs. 33.2% (n=40 vs. 56), p=.159. The concordance between the indication at the clinic and the surgery performed also increased (81.3 vs. 93.5%, p=.001). Throughout 2015 fewer complementary imaging test were requested from the clinic (78 vs. 35, p <.001), with a corresponding reduction in costs (€87,716 vs. €59,445). Multidisciplinary approach with routine DU can improve VA results, with a decrease in primary failure rate, higher likelihood of radiocephalic AVF, better management of dis-functioning AVF and lower radiological test costs. Copyright © 2018 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Use of routine clinical multimodality imaging in a rabbit model of osteoarthritis--part I.

    PubMed

    Bouchgua, M; Alexander, K; d'Anjou, M André; Girard, C A; Carmel, E Norman; Beauchamp, G; Richard, H; Laverty, S

    2009-02-01

    To evaluate in vivo the evolution of osteoarthritis (OA) lesions temporally in a rabbit model of OA with clinically available imaging modalities: computed radiography (CR), helical single-slice computed tomography (CT), and 1.5 tesla (T) magnetic resonance imaging (MRI). Imaging was performed on knees of anesthetized rabbits [10 anterior cruciate ligament transection (ACLT) and contralateral sham joints and six control rabbits] at baseline and at intervals up to 12 weeks post-surgery. Osteophytosis, subchondral bone sclerosis, bone marrow lesions (BMLs), femoropatellar effusion and articular cartilage were assessed. CT had the highest sensitivity (90%) and specificity (91%) to detect osteophytes. A significant increase in total joint osteophyte score occurred at all time-points post-operatively in the ACLT group alone. BMLs were identified and occurred most commonly in the lateral femoral condyle of the ACLT joints and were not identified in the tibia. A significant increase in joint effusion was present in the ACLT joints until 8 weeks after surgery. Bone sclerosis or cartilage defects were not reliably assessed with the selected imaging modalities. Combined, clinically available CT and 1.5 T MRI allowed the assessment of most of the characteristic lesions of OA and at early time-points in the development of the disease. However, the selected 1.5 T MRI sequences and acquisition times did not permit the detection of cartilage lesions in this rabbit OA model.

  11. Impact of audit of routine second-trimester cardiac images using a novel image-scoring method.

    PubMed

    Sairam, S; Awadh, A M A; Cook, K; Papageorghiou, A T; Carvalho, J S

    2009-05-01

    To assess the impact of using an objective scoring method to audit cardiac images obtained as part of the routine 21-23-week anomaly scan. A prospective audit and re-audit (6 months later) were conducted on cardiac images obtained by sonographers during the routine anomaly scan. A new image-scoring method was devised based on expected features in the four-chamber and outflow tract views. For each patient, scores were awarded for documentation and quality of individual views. These were called 'Documentation Scores' and 'View Scores' and were added to give a 'Patient Score' which represented the quality of screening provided by the sonographer for that particular patient (maximum score, 15). In order to assess the overall performance of sonographers, an 'Audit Score' was calculated for each by averaging his or her Patient Scores. In addition, to assess each sonographer's performance in relation to particular aspects of the various views, each was given their own 'Sonographer View Scores', derived from image documentation and details of four-chamber view (magnification, valve offset and septum) and left and right outflow tract views. All images were scored by two reviewers, jointly in the primary audit and independently in the re-audit. The scores from primary and re-audit were compared to assess the impact of feedback from the primary audit. Eight sonographers participated in the study. The median Audit Score increased significantly (P < 0.01), from 10.8 (range, 9.8-12.4) in the primary audit to 12.4 (range, 10.4-13.6) in the re-audit. Scores allocated by the two reviewers in the re-audit were not significantly different (P = 0.08). Objective scoring of fetal heart images is feasible and has a positive impact on the quality of cardiac images acquired at the time of the routine anomaly scan. This audit tool has the potential to be applied in every obstetric scanning unit and may improve the effectiveness of screening for congenital heart defects.

  12. XML-based scripting of multimodality image presentations in multidisciplinary clinical conferences

    NASA Astrophysics Data System (ADS)

    Ratib, Osman M.; Allada, Vivekanand; Dahlbom, Magdalena; Marcus, Phillip; Fine, Ian; Lapstra, Lorelle

    2002-05-01

    We developed a multi-modality image presentation software for display and analysis of images and related data from different imaging modalities. The software is part of a cardiac image review and presentation platform that supports integration of digital images and data from digital and analog media such as videotapes, analog x-ray films and 35 mm cine films. The software supports standard DICOM image files as well as AVI and PDF data formats. The system is integrated in a digital conferencing room that includes projections of digital and analog sources, remote videoconferencing capabilities, and an electronic whiteboard. The goal of this pilot project is to: 1) develop a new paradigm for image and data management for presentation in a clinically meaningful sequence adapted to case-specific scenarios, 2) design and implement a multi-modality review and conferencing workstation using component technology and customizable 'plug-in' architecture to support complex review and diagnostic tasks applicable to all cardiac imaging modalities and 3) develop an XML-based scripting model of image and data presentation for clinical review and decision making during routine clinical tasks and multidisciplinary clinical conferences.

  13. Clinical outcomes and cost effectiveness of accelerated diagnostic protocol in a chest pain center compared with routine care of patients with chest pain.

    PubMed

    Asher, Elad; Reuveni, Haim; Shlomo, Nir; Gerber, Yariv; Beigel, Roy; Narodetski, Michael; Eldar, Michael; Or, Jacob; Hod, Hanoch; Shamiss, Arie; Matetzky, Shlomi

    2015-01-01

    The aim of this study was to compare in patients presenting with acute chest pain the clinical outcomes and cost-effectiveness of an accelerated diagnostic protocol utilizing contemporary technology in a chest pain unit versus routine care in an internal medicine department. Hospital and 90-day course were prospectively studied in 585 consecutive low-moderate risk acute chest pain patients, of whom 304 were investigated in a designated chest pain center using a pre-specified accelerated diagnostic protocol, while 281 underwent routine care in an internal medicine ward. Hospitalization was longer in the routine care compared with the accelerated diagnostic protocol group (p<0.001). During hospitalization, 298 accelerated diagnostic protocol patients (98%) vs. 57 (20%) routine care patients underwent non-invasive testing, (p<0.001). Throughout the 90-day follow-up, diagnostic imaging testing was performed in 125 (44%) and 26 (9%) patients in the routine care and accelerated diagnostic protocol patients, respectively (p<0.001). Ultimately, most patients in both groups had non-invasive imaging testing. Accelerated diagnostic protocol patients compared with those receiving routine care was associated with a lower incidence of readmissions for chest pain [8 (3%) vs. 24 (9%), p<0.01], and acute coronary syndromes [1 (0.3%) vs. 9 (3.2%), p<0.01], during the follow-up period. The accelerated diagnostic protocol remained a predictor of lower acute coronary syndromes and readmissions after propensity score analysis [OR = 0.28 (CI 95% 0.14-0.59)]. Cost per patient was similar in both groups [($2510 vs. $2703 for the accelerated diagnostic protocol and routine care group, respectively, (p = 0.9)]. An accelerated diagnostic protocol is clinically superior and as cost effective as routine in acute chest pain patients, and may save time and resources.

  14. Clinical Outcomes and Cost Effectiveness of Accelerated Diagnostic Protocol in a Chest Pain Center Compared with Routine Care of Patients with Chest Pain

    PubMed Central

    Asher, Elad; Reuveni, Haim; Shlomo, Nir; Gerber, Yariv; Beigel, Roy; Narodetski, Michael; Eldar, Michael; Or, Jacob; Hod, Hanoch; Shamiss, Arie; Matetzky, Shlomi

    2015-01-01

    Aims The aim of this study was to compare in patients presenting with acute chest pain the clinical outcomes and cost-effectiveness of an accelerated diagnostic protocol utilizing contemporary technology in a chest pain unit versus routine care in an internal medicine department. Methods and Results Hospital and 90-day course were prospectively studied in 585 consecutive low-moderate risk acute chest pain patients, of whom 304 were investigated in a designated chest pain center using a pre-specified accelerated diagnostic protocol, while 281 underwent routine care in an internal medicine ward. Hospitalization was longer in the routine care compared with the accelerated diagnostic protocol group (p<0.001). During hospitalization, 298 accelerated diagnostic protocol patients (98%) vs. 57 (20%) routine care patients underwent non-invasive testing, (p<0.001). Throughout the 90-day follow-up, diagnostic imaging testing was performed in 125 (44%) and 26 (9%) patients in the routine care and accelerated diagnostic protocol patients, respectively (p<0.001). Ultimately, most patients in both groups had non-invasive imaging testing. Accelerated diagnostic protocol patients compared with those receiving routine care was associated with a lower incidence of readmissions for chest pain [8 (3%) vs. 24 (9%), p<0.01], and acute coronary syndromes [1 (0.3%) vs. 9 (3.2%), p<0.01], during the follow-up period. The accelerated diagnostic protocol remained a predictor of lower acute coronary syndromes and readmissions after propensity score analysis [OR = 0.28 (CI 95% 0.14–0.59)]. Cost per patient was similar in both groups [($2510 vs. $2703 for the accelerated diagnostic protocol and routine care group, respectively, (p = 0.9)]. Conclusion An accelerated diagnostic protocol is clinically superior and as cost effective as routine in acute chest pain patients, and may save time and resources. PMID:25622029

  15. SU-E-P-10: Imaging in the Cardiac Catheterization Lab - Technologies and Clinical Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fetterly, K

    2014-06-01

    Purpose: Diagnosis and treatment of cardiovascular disease in the cardiac catheterization laboratory is often aided by a multitude of imaging technologies. The purpose of this work is to highlight the contributions to patient care offered by the various imaging systems used during cardiovascular interventional procedures. Methods: Imaging technologies used in the cardiac catheterization lab were characterized by their fundamental technology and by the clinical applications for which they are used. Whether the modality is external to the patient, intravascular, or intracavity was specified. Specific clinical procedures for which multiple modalities are routinely used will be highlighted. Results: X-ray imaging modalitiesmore » include fluoroscopy/angiography and angiography CT. Ultrasound imaging is performed with external, trans-esophageal echocardiography (TEE), and intravascular (IVUS) transducers. Intravascular infrared optical coherence tomography (IVOCT) is used to assess vessel endothelium. Relatively large (>0.5 mm) anatomical structures are imaged with x-ray and ultrasound. IVUS and IVOCT provide high resolution images of vessel walls. Cardiac CT and MRI images are used to plan complex cardiovascular interventions. Advanced applications are used to spatially and temporally merge images from different technologies. Diagnosis and treatment of coronary artery disease frequently utilizes angiography and intra-vascular imaging, and treatment of complex structural heart conditions routinely includes use of multiple imaging modalities. Conclusion: There are several imaging modalities which are routinely used in the cardiac catheterization laboratory to diagnose and treat both coronary artery and structural heart disease. Multiple modalities are frequently used to enhance the quality and safety of procedures. The cardiac catheterization laboratory includes many opportunities for medical physicists to contribute substantially toward advancing patient care.« less

  16. Taking a new biomarker into routine use – A perspective from the routine clinical biochemistry laboratory

    PubMed Central

    Sturgeon, Catharine; Hill, Robert; Hortin, Glen L; Thompson, Douglas

    2010-01-01

    There is increasing pressure to provide cost-effective healthcare based on “best practice.” Consequently, new biomarkers are only likely to be introduced into routine clinical biochemistry departments if they are supported by a strong evidence base and if the results will improve patient management and outcome. This requires convincing evidence of the benefits of introducing the new test, ideally reflected in fewer hospital admissions, fewer additional investigations and/or fewer clinic visits. Carefully designed audit and cost-benefit studies in relevant patient groups must demonstrate that introducing the biomarker delivers an improved and more effective clinical pathway. From the laboratory perspective, pre-analytical requirements must be thoroughly investigated at an early stage. Good stability of the biomarker in relevant physiological matrices is essential to avoid the need for special processing. Absence of specific timing requirements for sampling and knowledge of the effect of medications that might be used to treat the patients in whom the biomarker will be measured is also highly desirable. Analytically, automation is essential in modern high-throughput clinical laboratories. Assays must therefore be robust, fulfilling standard requirements for linearity on dilution, precision and reproducibility, both within- and between-run. Provision of measurements by a limited number of specialized reference laboratories may be most appropriate, especially when a new biomarker is first introduced into routine practice. PMID:21137030

  17. Routine pharmacogenetic testing in clinical practice: dream or reality?

    PubMed

    Grossman, Iris

    2007-10-01

    Pharmacogenetics (PGx) has become progressively popular in recent years, thanks to growing anticipation among scientists, healthcare providers and the general public for the incorporation of genetic tests into the diagnostic arsenal at the physician's disposal. Indeed, much research has been dedicated to elucidation of genetic determinants underlying interindividual variability in pharmacokinetic parameters, as well as drug safety and efficacy. However, few PGx applications have thus far been realized in healthcare management. This review uses examples from PGx research of psychiatric drugs to illustrate why the current published findings are inadequate and insufficient for utilization as routine clinical predictors of treatment safety, efficacy or dosing. I therefore suggest the necessary steps to demonstrate the validity, utility and cost-effectiveness of PGx. These recommendations include a whole range of aspects, starting from standardization of criteria and assessment of the technical quality of genotyping assays, up to design of prospective PGx studies, providing the basis for reimbursement programs to be recognized in routine clinical practice.

  18. Nanoscale imaging of clinical specimens using pathology-optimized expansion microscopy

    PubMed Central

    Zhao, Yongxin; Bucur, Octavian; Irshad, Humayun; Chen, Fei; Weins, Astrid; Stancu, Andreea L.; Oh, Eun-Young; DiStasio, Marcello; Torous, Vanda; Glass, Benjamin; Stillman, Isaac E.; Schnitt, Stuart J.; Beck, Andrew H.; Boyden, Edward S.

    2017-01-01

    Expansion microscopy (ExM), a method for improving the resolution of light microscopy by physically expanding the specimen, has not been applied to clinical tissue samples. Here we report a clinically optimized form of ExM that supports nanoscale imaging of human tissue specimens that have been fixed with formalin, embedded in paraffin, stained with hematoxylin and eosin (H&E), and/or fresh frozen. The method, which we call expansion pathology (ExPath), converts clinical samples into an ExM-compatible state, then applies an ExM protocol with protein anchoring and mechanical homogenization steps optimized for clinical samples. ExPath enables ~70 nm resolution imaging of diverse biomolecules in intact tissues using conventional diffraction-limited microscopes, and standard antibody and fluorescent DNA in situ hybridization reagents. We use ExPath for optical diagnosis of kidney minimal-change disease, which previously required electron microscopy (EM), and demonstrate high-fidelity computational discrimination between early breast neoplastic lesions that to date have challenged human judgment. ExPath may enable the routine use of nanoscale imaging in pathology and clinical research. PMID:28714966

  19. Nanoscale imaging of clinical specimens using pathology-optimized expansion microscopy.

    PubMed

    Zhao, Yongxin; Bucur, Octavian; Irshad, Humayun; Chen, Fei; Weins, Astrid; Stancu, Andreea L; Oh, Eun-Young; DiStasio, Marcello; Torous, Vanda; Glass, Benjamin; Stillman, Isaac E; Schnitt, Stuart J; Beck, Andrew H; Boyden, Edward S

    2017-08-01

    Expansion microscopy (ExM), a method for improving the resolution of light microscopy by physically expanding a specimen, has not been applied to clinical tissue samples. Here we report a clinically optimized form of ExM that supports nanoscale imaging of human tissue specimens that have been fixed with formalin, embedded in paraffin, stained with hematoxylin and eosin, and/or fresh frozen. The method, which we call expansion pathology (ExPath), converts clinical samples into an ExM-compatible state, then applies an ExM protocol with protein anchoring and mechanical homogenization steps optimized for clinical samples. ExPath enables ∼70-nm-resolution imaging of diverse biomolecules in intact tissues using conventional diffraction-limited microscopes and standard antibody and fluorescent DNA in situ hybridization reagents. We use ExPath for optical diagnosis of kidney minimal-change disease, a process that previously required electron microscopy, and we demonstrate high-fidelity computational discrimination between early breast neoplastic lesions for which pathologists often disagree in classification. ExPath may enable the routine use of nanoscale imaging in pathology and clinical research.

  20. How characteristic routines of clinical departments influence students' self-regulated learning: A grounded theory study.

    PubMed

    Berkhout, J J; Slootweg, I A; Helmich, E; Teunissen, P W; van der Vleuten, C P M; Jaarsma, A D C

    2017-11-01

    In clerkships, students are expected to self-regulate their learning. How clinical departments and their routine approach on clerkships influences students' self-regulated learning (SRL) is unknown. This study explores how characteristic routines of clinical departments influence medical students' SRL. Six focus groups including 39 purposively sampled participants from one Dutch university were organized to study how characteristic routines of clinical departments influenced medical students' SRL from a constructivist paradigm, using grounded theory methodology. The focus groups were audio recorded, transcribed verbatim and were analyzed iteratively using constant comparison and open, axial and interpretive coding. Students described that clinical departments influenced their SRL through routines which affected the professional relationships they could engage in and affected their perception of a department's invested effort in them. Students' SRL in a clerkship can be supported by enabling them to engage others in their SRL and by having them feel that effort is invested in their learning. Our study gives a practical insight in how clinical departments influenced students' SRL. Clinical departments can affect students' motivation to engage in SRL, influence the variety of SRL strategies that students can use and how meaningful students perceive their SRL experiences to be.

  1. Advance Care Planning: Understanding Clinical Routines and Experiences of Interprofessional Team Members in Diverse Health Care Settings.

    PubMed

    Arnett, Kelly; Sudore, Rebecca L; Nowels, David; Feng, Cindy X; Levy, Cari R; Lum, Hillary D

    2017-12-01

    Interprofessional health care team members consider advance care planning (ACP) to be important, yet gaps remain in systematic clinical routines to support ACP. A clearer understanding of the interprofessional team members' perspectives on ACP clinical routines in diverse settings is needed. One hundred eighteen health care team members from community-based clinics, long-term care facilities, academic clinics, federally qualified health centers, and hospitals participated in a 35-question, cross-sectional online survey to assess clinical routines, workflow processes, and policies relating to ACP. Respondents were 53% physicians, 18% advanced practice nurses, 11% nurses, and 18% other interprofessional team members including administrators, chaplains, social workers, and others. Regarding clinical routines, respondents reported that several interprofessional team members play a role in facilitating ACP (ie, physician, social worker, nurse, others). Most (62%) settings did not have, or did not know of, policies related to ACP documentation. Only 14% of settings had a patient education program. Two-thirds of the respondents said that addressing ACP is a high priority and 85% felt that nonphysicians could have ACP conversations with appropriate training. The clinical resources needed to improve clinical routines included training for providers and staff, dedicated staff to facilitate ACP, and availability of patient/family educational materials. Although interprofessional health care team members consider ACP a priority and several team members may be involved, clinical settings lack systematic clinical routines to support ACP. Patient educational materials, interprofessional team training, and policies to support ACP clinical workflows that do not rely solely on physicians could improve ACP across diverse clinical settings.

  2. Routine clinical application of virtual reality in abdominal surgery.

    PubMed

    Sampogna, Gianluca; Pugliese, Raffaele; Elli, Marco; Vanzulli, Angelo; Forgione, Antonello

    2017-06-01

    The advantages of 3D reconstruction, immersive virtual reality (VR) and 3D printing in abdominal surgery have been enunciated for many years, but still today their application in routine clinical practice is almost nil. We investigate their feasibility, user appreciation and clinical impact. Fifteen patients undergoing pancreatic, hepatic or renal surgery were studied realizing a 3D reconstruction of target anatomy. Then, an immersive VR environment was developed to import 3D models, and some details of the 3D scene were printed. All the phases of our workflow employed open-source software and low-cost hardware, easily implementable by other surgical services. A qualitative evaluation of the three approaches was performed by 20 surgeons, who filled in a specific questionnaire regarding a clinical case for each organ considered. Preoperative surgical planning and intraoperative guidance was feasible for all patients included in the study. The vast majority of surgeons interviewed scored their quality and usefulness as very good. Despite extra time, costs and efforts necessary to implement these systems, the benefits shown by the analysis of questionnaires recommend to invest more resources to train physicians to adopt these technologies routinely, even if further and larger studies are still mandatory.

  3. Companion diagnostics and molecular imaging-enhanced approaches for oncology clinical trials.

    PubMed

    Van Heertum, Ronald L; Scarimbolo, Robert; Ford, Robert; Berdougo, Eli; O'Neal, Michael

    2015-01-01

    In the era of personalized medicine, diagnostic approaches are helping pharmaceutical and biotechnology sponsors streamline the clinical trial process. Molecular assays and diagnostic imaging are routinely being used to stratify patients for treatment, monitor disease, and provide reliable early clinical phase assessments. The importance of diagnostic approaches in drug development is highlighted by the rapidly expanding global cancer diagnostics market and the emergent attention of regulatory agencies worldwide, who are beginning to offer more structured platforms and guidance for this area. In this paper, we highlight the key benefits of using companion diagnostics and diagnostic imaging with a focus on oncology clinical trials. Nuclear imaging using widely available radiopharmaceuticals in conjunction with molecular imaging of oncology targets has opened the door to more accurate disease assessment and the modernization of standard criteria for the evaluation, staging, and treatment responses of cancer patients. Furthermore, the introduction and validation of quantitative molecular imaging continues to drive and optimize the field of oncology diagnostics. Given their pivotal role in disease assessment and treatment, the validation and commercialization of diagnostic tools will continue to advance oncology clinical trials, support new oncology drugs, and promote better patient outcomes.

  4. Imaging: Guiding the Clinical Translation of Cardiac Stem Cell Therapy

    PubMed Central

    Nguyen, Patricia K.; Lan, Feng; Wang, Yongming; Wu, Joseph C.

    2011-01-01

    Stem cells have been touted as the holy grail of medical therapy with promises to regenerate cardiac tissue, but it appears the jury is still out on this novel therapy. Using advanced imaging technology, scientists have discovered that these cells do not survive nor engraft long-term. In addition, only marginal benefit has been observed in large animal studies and human trials. However, all is not lost. Further application of advanced imaging technology will help scientists unravel the mysteries of stem cell therapy and address the clinical hurdles facing its routine implementation. In this review, we will discuss how advanced imaging technology will help investigators better define the optimal delivery method, improve survival and engraftment, and evaluate efficacy and safety. Insights gained from this review may direct the development of future preclinical investigations and clinical trials. PMID:21960727

  5. The clinical information system GastroBase: integration of image processing and laboratory communication.

    PubMed

    Kocna, P

    1995-01-01

    GastroBase, a clinical information system, incorporates patient identification, medical records, images, laboratory data, patient history, physical examination, and other patient-related information. Program modules are written in C; all data is processed using Novell-Btrieve data manager. Patient identification database represents the main core of this information systems. A graphic library developed in the past year and graphic modules with a special video-card enables the storing, archiving, and linking of different images to the electronic patient-medical-record. GastroBase has been running for more than four years in daily routine and the database contains more than 25,000 medical records and 1,500 images. This new version of GastroBase is now incorporated into the clinical information system of University Clinic in Prague.

  6. Clinical Outcome of Degenerative Mitral Regurgitation: Critical Importance of Echocardiographic Quantitative Assessment in Routine Practice.

    PubMed

    Antoine, Clemence; Benfari, Giovanni; Michelena, Hector I; Malouf, Joseph F; Nkomo, Vuyisile T; Thapa, Prabin; Enriquez-Sarano, Maurice

    2018-05-31

    Background -Echocardiographic quantitation of degenerative mitral regurgitation (DMR) is recommended whenever possible in clinical guidelines but is criticized and its scalability to routine clinical practice doubted. We hypothesized that echocardiographic DMR quantitation, performed in routine clinical practice by multiple practitioners predicts independently long-term survival, and thus is essential to DMR management. Methods -We included patients diagnosed with isolated mitral-valve-prolapse 2003-2011 and any degree of MR quantified by any physician/sonographer in routine clinical practice. Clinical/echocardiographic data acquired at diagnosis were retrieved electronically. Endpoint was mortality under medical treatment analyzed by Kaplan-Meir method and Proportional-Hazard models. Results -The cohort included 3914 patients (55% male) aged 62±17 years, with left ventricular ejection fraction (LVEF) 63±8% and routinely measured effective regurgitant orifice area (EROA) 19[0-40] mm 2 During follow-up (6.7±3.1 years) 696 patients died under medical management and 1263 underwent mitral surgery. In multivariate analysis, routinely measured EROA was associated with mortality (adjusted-hazard-ratio 1.19[1.13-1.24] p<0.0001 per-10mm 2 ) independently of LVEF and end-systolic diameter, symptoms and age/comorbidities. The association between routinely measured EROA and mortality persisted with competitive risk modeling (adjusted hazard-ratio 1.15[1.10-1.20] per 10mm 2 p<0.0001), or in patients without guideline-based Class I/II surgical triggers (adjusted hazard ratio 1.19[1.10-1.28] per 10mm 2 p<0.0001) and in all subgroups examined (all p<0.01). Spline curve analysis showed that, compared with general population mortality, excess mortality appears for moderate DMR (EROA ≥20mm 2 ) becomes notable ≥EROA 30mm 2 and steadily increases with higher EROA levels, > 40 mm 2 threshold. Conclusions -Echocardiographic DMR quantitation is scalable to routine practice and is

  7. Experience of domestic violence routine screening in Family Planning NSW clinics.

    PubMed

    Hunter, Tara; Botfield, Jessica R; Estoesta, Jane; Markham, Pippa; Robertson, Sarah; McGeechan, Kevin

    2017-04-01

    This study reviewed implementation of the Domestic Violence Routine Screening (DVRS) program at Family Planning NSW and outcomes of screening to determine the feasibility of routine screening in a family planning setting and the suitability of this program in the context of women's reproductive and sexual health. A retrospective review of medical records was undertaken of eligible women attending Family Planning NSW clinics between 1 January and 31 December 2015. Modified Poisson regression was used to estimate prevalence ratios and assess association between binary outcomes and client characteristics. Of 13440 eligible women, 5491 were screened (41%). Number of visits, clinic attended, age, employment status and disability were associated with completion of screening. In all, 220 women (4.0%) disclosed domestic violence. Factors associated with disclosure were clinic attended, age group, region of birth, employment status, education and disability. Women who disclosed domestic violence were more likely to have discussed issues related to sexually transmissible infections in their consultation. All women who disclosed were assessed for any safety concerns and offered a range of suitable referral options. Although routine screening may not be appropriate in all health settings, given associations between domestic violence and sexual and reproductive health, a DVRS program is considered appropriate in sexual and reproductive health clinics and appears to be feasible in a service such as Family Planning NSW. Consistent implementation of the program should continue at Family Planning NSW and be expanded to other family planning services in Australia to support identification and early intervention for women affected by domestic violence.

  8. Quality of routine diagnostic abdominal images generated from a novel detector-based spectral CT scanner: a technical report on a phantom and clinical study.

    PubMed

    Hojjati, Mojgan; Van Hedent, Steven; Rassouli, Negin; Tatsuoka, Curtis; Jordan, David; Dhanantwari, Amar; Rajiah, Prabhakar

    2017-11-01

    To evaluate the image quality of routine diagnostic images generated from a novel detector-based spectral detector CT (SDCT) and compare it with CT images obtained from a conventional scanner with an energy-integrating detector (Brilliance iCT), Routine diagnostic (conventional/polyenergetic) images are non-material-specific images that resemble single-energy images obtained at the same radiation, METHODS: ACR guideline-based phantom evaluations were performed on both SDCT and iCT for CT adult body protocol. Retrospective analysis was performed on 50 abdominal CT scans from each scanner. Identical ROIs were placed at multiple locations in the abdomen and attenuation, noise, SNR, and CNR were measured. Subjective image quality analysis on a 5-point Likert scale was performed by 2 readers for enhancement, noise, and image quality. On phantom studies, SDCT images met the ACR requirements for CT number and deviation, CNR and effective radiation dose. In patients, the qualitative scores were significantly higher for the SDCT than the iCT, including enhancement (4.79 ± 0.38 vs. 4.60 ± 0.51, p = 0.005), noise (4.63 ± 0.42 vs. 4.29 ± 0.50, p = 0.000), and quality (4.85 ± 0.32, vs. 4.57 ± 0.50, p = 0.000). The SNR was higher in SDCT than iCT for liver (7.4 ± 4.2 vs. 7.2 ± 5.3, p = 0.662), spleen (8.6 ± 4.1 vs. 7.4 ± 3.5, p = 0.152), kidney (11.1 ± 6.3 vs. 8.7 ± 5.0, p = 0.033), pancreas (6.90 ± 3.45 vs 6.11 ± 2.64, p = 0.303), aorta (14.2 ± 6.2 vs. 11.0 ± 4.9, p = 0.007), but was slightly lower in lumbar-vertebra (7.7 ± 4.2 vs. 7.8 ± 4.5, p = 0.937). The CNR of the SDCT was also higher than iCT for all abdominal organs. Image quality of routine diagnostic images from the SDCT is comparable to images of a conventional CT scanner with energy-integrating detectors, making it suitable for diagnostic purposes.

  9. Lipemia interferences in routine clinical biochemical tests.

    PubMed

    Calmarza, Pilar; Cordero, José

    2011-01-01

    Lipemic specimens are a common and frequent, but yet unresolved problem in clinical chemistry, and may produce significant interferences in the analytical results of different biochemical parameters. The aim of this study was to examine the effect of lipid removal using ultracentrifugation of lipemic samples, on some routine biochemistry parameters. Among all the samples obtained daily in our laboratory, the ones which were visibly muddy were selected and underwent to a process of ultracentrifugation, being determined a variety of biochemical tests before and after ultracentrifugation. A total of 110 samples were studied. We found significant differences in all the parameters studied except for total bilirubin, glucose, gamma-glutamyl transferase (GGT) and aspartate aminotransferase (AST). The greatest differences in the parameters analyzed were found in the concentration of alanine aminotransferase (ALT) (7.36%) and the smallest ones in the concentration of glucose (0.014%). Clinically significant interferences were found for phosphorus, creatinine, total protein and calcium. Lipemia causes clinically significant interferences for phosphorus, creatinine, total protein and calcium measurement and those interferences could be effectively removed by ultracentrifugation.

  10. Evaluation of web-based annotation of ophthalmic images for multicentric clinical trials.

    PubMed

    Chalam, K V; Jain, P; Shah, V A; Shah, Gaurav Y

    2006-06-01

    An Internet browser-based annotation system can be used to identify and describe features in digitalized retinal images, in multicentric clinical trials, in real time. In this web-based annotation system, the user employs a mouse to draw and create annotations on a transparent layer, that encapsulates the observations and interpretations of a specific image. Multiple annotation layers may be overlaid on a single image. These layers may correspond to annotations by different users on the same image or annotations of a temporal sequence of images of a disease process, over a period of time. In addition, geometrical properties of annotated figures may be computed and measured. The annotations are stored in a central repository database on a server, which can be retrieved by multiple users in real time. This system facilitates objective evaluation of digital images and comparison of double-blind readings of digital photographs, with an identifiable audit trail. Annotation of ophthalmic images allowed clinically feasible and useful interpretation to track properties of an area of fundus pathology. This provided an objective method to monitor properties of pathologies over time, an essential component of multicentric clinical trials. The annotation system also allowed users to view stereoscopic images that are stereo pairs. This web-based annotation system is useful and valuable in monitoring patient care, in multicentric clinical trials, telemedicine, teaching and routine clinical settings.

  11. A new SPECT/CT reconstruction algorithm: reliability and accuracy in clinical routine for non-oncologic bone diseases.

    PubMed

    Delcroix, Olivier; Robin, Philippe; Gouillou, Maelenn; Le Duc-Pennec, Alexandra; Alavi, Zarrin; Le Roux, Pierre-Yves; Abgral, Ronan; Salaun, Pierre-Yves; Bourhis, David; Querellou, Solène

    2018-02-12

    xSPECT Bone® (xB) is a new reconstruction algorithm developed by Siemens® in bone hybrid imaging (SPECT/CT). A CT-based tissue segmentation is incorporated into SPECT reconstruction to provide SPECT images with bone anatomy appearance. The objectives of this study were to assess xB/CT reconstruction diagnostic reliability and accuracy in comparison with Flash 3D® (F3D)/CT in clinical routine. Two hundred thirteen consecutive patients referred to the Brest Nuclear Medicine Department for non-oncological bone diseases were evaluated retrospectively. Two hundred seven SPECT/CT were included. All SPECT/CT were independently interpreted by two nuclear medicine physicians (a junior and a senior expert) with xB/CT then with F3D/CT three months later. Inter-observer agreement (IOA) and diagnostic confidence were determined using McNemar test, and unweighted Kappa coefficient. The study objectives were then re-assessed for validation through > 18 months of clinical and paraclinical follow-up. No statistically significant differences between IOA xB and IOA F3D were found (p = 0.532). Agreement for xB after categorical classification of the diagnoses was high (κ xB = 0.89 [95% CI 0.84 -0.93]) but without statistically significant difference F3D (κ F3D = 0.90 [95% CI 0.86 - 0.94]). Thirty-one (14.9%) inter-reconstruction diagnostic discrepancies were observed of which 21 (10.1%) were classified as major. The follow-up confirmed the diagnosis of F3D in 10 cases, xB in 6 cases and was non-contributory in 5 cases. xB reconstruction algorithm was found reliable, providing high interobserver agreement and similar diagnostic confidence to F3D reconstruction in clinical routine.

  12. Correlation between Clinical Features and Magnetic Resonance Imaging Findings in Lumbar Disc Prolapse.

    PubMed

    Thapa, S S; Lakhey, R B; Sharma, P; Pokhrel, R K

    2016-05-01

    Magnetic resonance imaging is routinely done for diagnosis of lumbar disc prolapse. Many abnormalities of disc are observed even in asymptomatic patient.This study was conducted tocorrelate these abnormalities observed on Magnetic resonance imaging and clinical features of lumbar disc prolapse. A This prospective analytical study includes 57 cases of lumbar disc prolapse presenting to Department of Orthopedics, Tribhuvan University Teaching Hospital from March 2011 to August 2012. All patientshad Magnetic resonance imaging of lumbar spine and the findings regarding type, level and position of lumbar disc prolapse, any neural canal or foraminal compromise was recorded. These imaging findings were then correlated with clinical signs and symptoms. Chi-square test was used to find out p-value for correlation between clinical features and Magnetic resonance imaging findings using SPSS 17.0. This study included 57 patients, with mean age 36.8 years. Of them 41(71.9%) patients had radicular leg pain along specific dermatome. Magnetic resonance imaging showed 104 lumbar disc prolapselevel. Disc prolapse at L4-L5 and L5-S1 level constituted 85.5%.Magnetic resonance imaging findings of neural foramina compromise and nerve root compression were fairly correlated withclinical findings of radicular pain and neurological deficit. Clinical features and Magnetic resonance imaging findings of lumbar discprolasehad faircorrelation, but all imaging abnormalities do not have a clinical significance.

  13. Early clinical applications for imaging at microscopic detail: microfocus computed tomography (micro-CT).

    PubMed

    Hutchinson, J Ciaran; Shelmerdine, Susan C; Simcock, Ian C; Sebire, Neil J; Arthurs, Owen J

    2017-07-01

    Microfocus CT (micro-CT) has traditionally been used in industry and preclinical studies, although it may find new applicability in the routine clinical setting. It can provide high-resolution three-dimensional digital imaging data sets to the same level of detail as microscopic examination without the need for tissue dissection. Micro-CT is already enabling non-invasive detailed internal assessment of various tissue specimens, particularly in breast imaging and early gestational fetal autopsy, not previously possible from more conventional modalities such as MRI or CT. In this review, we discuss the technical aspects behind micro-CT image acquisition, how early work with small animal studies have informed our knowledge of human disease and the imaging performed so far on human tissue specimens. We conclude with potential future clinical applications of this novel and emerging technique.

  14. Support Routines for In Situ Image Processing

    NASA Technical Reports Server (NTRS)

    Deen, Robert G.; Pariser, Oleg; Yeates, Matthew C.; Lee, Hyun H.; Lorre, Jean

    2013-01-01

    This software consists of a set of application programs that support ground-based image processing for in situ missions. These programs represent a collection of utility routines that perform miscellaneous functions in the context of the ground data system. Each one fulfills some specific need as determined via operational experience. The most unique aspect to these programs is that they are integrated into the large, in situ image processing system via the PIG (Planetary Image Geometry) library. They work directly with space in situ data, understanding the appropriate image meta-data fields and updating them properly. The programs themselves are completely multimission; all mission dependencies are handled by PIG. This suite of programs consists of: (1)marscahv: Generates a linearized, epi-polar aligned image given a stereo pair of images. These images are optimized for 1-D stereo correlations, (2) marscheckcm: Compares the camera model in an image label with one derived via kinematics modeling on the ground, (3) marschkovl: Checks the overlaps between a list of images in order to determine which might be stereo pairs. This is useful for non-traditional stereo images like long-baseline or those from an articulating arm camera, (4) marscoordtrans: Translates mosaic coordinates from one form into another, (5) marsdispcompare: Checks a Left Right stereo disparity image against a Right Left disparity image to ensure they are consistent with each other, (6) marsdispwarp: Takes one image of a stereo pair and warps it through a disparity map to create a synthetic opposite- eye image. For example, a right eye image could be transformed to look like it was taken from the left eye via this program, (7) marsfidfinder: Finds fiducial markers in an image by projecting their approximate location and then using correlation to locate the markers to subpixel accuracy. These fiducial markets are small targets attached to the spacecraft surface. This helps verify, or improve, the

  15. SPIRIT: Systematic Planning of Intelligent Reuse of Integrated Clinical Routine Data. A Conceptual Best-practice Framework and Procedure Model.

    PubMed

    Hackl, W O; Ammenwerth, E

    2016-01-01

    Secondary use of clinical routine data is receiving an increasing amount of attention in biomedicine and healthcare. However, building and analysing integrated clinical routine data repositories are nontrivial, challenging tasks. As in most evolving fields, recognized standards, well-proven methodological frameworks, or accurately described best-practice approaches for the systematic planning of solutions for secondary use of routine medical record data are missing. We propose a conceptual best-practice framework and procedure model for the systematic planning of intelligent reuse of integrated clinical routine data (SPIRIT). SPIRIT was developed based on a broad literature overview and further refined in two case studies with different kinds of clinical routine data, including process-oriented nursing data from a large hospital group and high-volume multimodal clinical data from a neurologic intensive care unit. SPIRIT aims at tailoring secondary use solutions to specific needs of single departments without losing sight of the institution as a whole. It provides a general conceptual best-practice framework consisting of three parts: First, a secondary use strategy for the whole organization is determined. Second, comprehensive analyses are conducted from two different viewpoints to define the requirements regarding a clinical routine data reuse solution at the system level from the data perspective (BOTTOM UP) and at the strategic level from the future users perspective (TOP DOWN). An obligatory clinical context analysis (IN BETWEEN) facilitates refinement, combination, and integration of the different requirements. The third part of SPIRIT is dedicated to implementation, which comprises design and realization of clinical data integration and management as well as data analysis solutions. The SPIRIT framework is intended to be used to systematically plan the intelligent reuse of clinical routine data for multiple purposes, which often was not intended when the

  16. Three-dimensional anisotropy contrast periodically rotated overlapping parallel lines with enhanced reconstruction (3DAC PROPELLER) on a 3.0T system: a new modality for routine clinical neuroimaging.

    PubMed

    Nakada, Tsutomu; Matsuzawa, Hitoshi; Fujii, Yukihiko; Takahashi, Hitoshi; Nishizawa, Masatoyo; Kwee, Ingrid L

    2006-07-01

    Clinical magnetic resonance imaging (MRI) has recently entered the "high-field" era, and systems equipped with 3.0-4.0T superconductive magnets are becoming the gold standard for diagnostic imaging. While higher signal-to-noise ratio (S/N) is a definite advantage of higher field systems, higher susceptibility effect remains to be a significant trade-off. To take advantage of a higher field system in performing routine clinical images of higher anatomical resolution, we implemented a vector contrast image technique to 3.0T imaging, three-dimensional anisotropy contrast (3DAC), with a PROPELLER (Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction) sequence, a method capable of effectively eliminating undesired artifacts on rapid diffusion imaging sequences. One hundred subjects (20 normal volunteers and 80 volunteers with various central nervous system diseases) participated in the study. Anisotropic diffusion-weighted PROPELLER images were obtained on a General Electric (Waukesha, WI, USA) Signa 3.0T for each axis, with b-value of 1100 sec/mm(2). Subsequently, 3DAC images were constructed using in-house software written on MATLAB (MathWorks, Natick, MA, USA). The vector contrast allows for providing exquisite anatomical detail illustrated by clear identification of all major tracts through the entire brain. 3DAC images provide better anatomical resolution for brainstem glioma than higher-resolution T2 reversed images. Degenerative processes of disease-specific tracts were clearly identified as illustrated in cases of multiple system atrophy and Joseph-Machado disease. Anatomical images of significantly higher resolution than the best current standard, T2 reversed images, were successfully obtained. As a technique readily applicable under routine clinical setting, 3DAC PROPELLER on a 3.0T system will be a powerful addition to diagnostic imaging.

  17. An automated image processing routine for segmentation of cell cytoplasms in high-resolution autofluorescence images

    NASA Astrophysics Data System (ADS)

    Walsh, Alex J.; Skala, Melissa C.

    2014-02-01

    The heterogeneity of genotypes and phenotypes within cancers is correlated with disease progression and drug-resistant cellular sub-populations. Therefore, robust techniques capable of probing majority and minority cell populations are important both for cancer diagnostics and therapy monitoring. Herein, we present a modified CellProfiler routine to isolate cytoplasmic fluorescence signal on a single cell level from high resolution auto-fluorescence microscopic images.

  18. New clinical opportunities for retinal vascular imaging: adaptive optics to OCT angiography

    NASA Astrophysics Data System (ADS)

    Rosen, Richard; Chui, Toco; Weitz, Rishard; Dubra, Alfredo; Carroll, Joseph; Garcia, Patricia; Pinhas, Alexander; Scripsema, Nicole; Mo, Shelley; Agemy, Steven; Krawitz, Brian

    2018-03-01

    As techniques of retinal imaging have evolved, anatomic features that were only assessable in the laboratory have become available in the clinic for patient care. The retinal capillaries were initially described on microscope sections in the pathology laboratory. As optical methods have advanced these features have become part of the routine clinical landscape inspected daily by physicians. This paper briefly traces the evolution of these techniques and shows how they fit into the modern diagnostic armamentarium of ophthalmic retinal care.

  19. Fundamentals of functional imaging I: current clinical techniques.

    PubMed

    Luna, A; Martín Noguerol, T; Mata, L Alcalá

    2018-05-01

    Imaging techniques can establish a structural, physiological, and molecular phenotype for cancer, which helps enable accurate diagnosis and personalized treatment. In recent years, various imaging techniques that make it possible to study the functional characteristics of tumors quantitatively and reproducibly have been introduced and have become established in routine clinical practice. Perfusion studies enable us to estimate the microcirculation as well as tumor angiogenesis and permeability using ultrafast dynamic acquisitions with ultrasound, computed tomography, or magnetic resonance (MR) imaging. Diffusion-weighted sequences now form part of state-of-the-art MR imaging protocols to evaluate oncologic lesions in any anatomic location. Diffusion-weighted imaging provides information about the occupation of the extracellular and extravascular space and indirectly estimates the cellularity and apoptosis of tumors, having demonstrated its relation with biologic aggressiveness in various tumor lines and its usefulness in the evaluation of the early response to systemic and local targeted therapies. Another tool is hydrogen proton MR spectroscopy, which is used mainly in the study of the metabolic characteristics of brain tumors. However, the complexity of the technique and its lack of reproducibility have limited its clinical use in other anatomic areas, although much experience with the use of this technique in the assessment of prostate and breast cancers as well as liver lesions has also accumulated. This review analyzes the imaging techniques that make it possible to evaluate the physiological and molecular characteristics of cancer that have already been introduced into clinical practice, such as techniques that evaluate angiogenesis through dynamic acquisitions after the administration of contrast material, diffusion-weighted imaging, or hydrogen proton MR spectroscopy, as well as their principal applications in oncology. Copyright © 2018 SERAM. Publicado

  20. Image quality comparison of two adaptive statistical iterative reconstruction (ASiR, ASiR-V) algorithms and filtered back projection in routine liver CT.

    PubMed

    Chen, Li-Hong; Jin, Chao; Li, Jian-Ying; Wang, Ge-Liang; Jia, Yong-Jun; Duan, Hai-Feng; Pan, Ning; Guo, Jianxin

    2018-06-06

    To compare image quality of two adaptive statistical iterative reconstruction (ASiR and ASiR-V) algorithms using objective and subjective metrics for routine liver CT, with the conventional filtered back projection (FBP) reconstructions as reference standards. This institutional review board-approved study included 52 patients with clinically suspected hepatic metastases. Patients were divided equally into ASiR and ASiR-V groups with same scan parameters. Images were reconstructed with ASiR and ASiR-V from 0 (FBP) to 100% blending percentages at 10% interval in its respective group. Mean and standard deviation of CT numbers for liver parenchyma were recorded. Two experienced radiologists reviewed all images for image quality blindly and independently. Data were statistically analyzed. There was no difference in CT dose index between ASiR and ASiR-V groups. As the percentage of ASiR and ASiR-V increased from 10 to 100% , image noise reduced by 8.6 -57.9% and 8.9-81.6%, respectively, compared with FBP. There was substantial interobserver agreement in image quality assessment for ASiR and ASiR-V images. Compared with FBP reconstruction, subjective image quality scores of ASiR and ASiR-V improved significantly as percentage increased from 10 to 80% for ASiR (peaked at 50% with 32.2% noise reduction) and from 10 to 90% (peaked at 60% with 51.5% noise reduction) for ASiR-V. Both ASiR and ASiR-V improved the objective and subjective image quality for routine liver CT compared with FBP. ASiR-V provided further image quality improvement with higher acceptable percentage than ASiR, and ASiR-V60% had the highest image quality score. Advances in knowledge: (1) Both ASiR and ASiR-V significantly reduce image noise compared with conventional FBP reconstruction. (2) ASiR-V with 60 blending percentage provides the highest image quality score in routine liver CT.

  1. Clinical Amyloid Imaging.

    PubMed

    Mallik, Atul; Drzezga, Alex; Minoshima, Satoshi

    2017-01-01

    Amyloid plaques, along with neurofibrillary tangles, are a neuropathologic hallmark of Alzheimer disease (AD). Recently, amyloid PET radiotracers have been developed and approved for clinical use in the evaluation of suspected neurodegenerative disorders. In both research and clinical settings, amyloid PET imaging has provided important diagnostic and prognostic information for the management of patients with possible AD, mild cognitive impairment (MCI), and other challenging diagnostic presentations. Although the overall impact of amyloid imaging is still being evaluated, the Society of Nuclear Medicine and Molecular Imaging and Alzheimer's Association Amyloid Imaging Task Force have created appropriate use criteria for the standard clinical use of amyloid PET imaging. By the appropriate use criteria, amyloid imaging is appropriate for patients with (1) persistent or unexplained MCI, (2) AD as a possible but still uncertain diagnosis after expert evaluation and (3) atypically early-age-onset progressive dementia. To better understand the clinical and economic effect of amyloid imaging, the Imaging Dementia-Evidence for Amyloid Scanning (IDEAS) study is an ongoing large multicenter study in the United States, which is evaluating how amyloid imaging affects diagnosis, management, and outcomes for cognitively impaired patients who cannot be completely evaluated by clinical assessment alone. Multiple other large-scale studies are evaluating the prognostic role of amyloid PET imaging for predicting MCI progression to AD in general and high-risk populations. At the same time, amyloid imaging is an important tool for evaluating potential disease-modifying therapies for AD. Overall, the increased use of amyloid PET imaging has led to a better understanding of the strengths and limitations of this imaging modality and how it may best be used with other clinical, molecular, and imaging assessment techniques for the diagnosis and management of neurodegenerative disorders

  2. The quality of clinical maternal and neonatal healthcare - a strategy for identifying 'routine care signal functions'.

    PubMed

    Brenner, Stephan; De Allegri, Manuela; Gabrysch, Sabine; Chinkhumba, Jobiba; Sarker, Malabika; Muula, Adamson S

    2015-01-01

    A variety of clinical process indicators exists to measure the quality of care provided by maternal and neonatal health (MNH) programs. To allow comparison across MNH programs in low- and middle-income countries (LMICs), a core set of essential process indicators is needed. Although such a core set is available for emergency obstetric care (EmOC), the 'EmOC signal functions', a similar approach is currently missing for MNH routine care evaluation. We describe a strategy for identifying core process indicators for routine care and illustrate their usefulness in a field example. We first developed an indicator selection strategy by combining epidemiological and programmatic aspects relevant to MNH in LMICs. We then identified routine care process indicators meeting our selection criteria by reviewing existing quality of care assessment protocols. We grouped these indicators into three categories based on their main function in addressing risk factors of maternal or neonatal complications. We then tested this indicator set in a study assessing MNH quality of clinical care in 33 health facilities in Malawi. Our strategy identified 51 routine care processes: 23 related to initial patient risk assessment, 17 to risk monitoring, 11 to risk prevention. During the clinical performance assessment a total of 82 cases were observed. Birth attendants' adherence to clinical standards was lowest in relation to risk monitoring processes. In relation to major complications, routine care processes addressing fetal and newborn distress were performed relatively consistently, but there were major gaps in the performance of routine care processes addressing bleeding, infection, and pre-eclampsia risks. The identified set of process indicators could identify major gaps in the quality of obstetric and neonatal care provided during the intra- and immediate postpartum period. We hope our suggested indicators for essential routine care processes will contribute to streamlining MNH program

  3. Utility of routine psychological screening in the childhood cancer survivor clinic.

    PubMed

    Recklitis, Christopher; O'Leary, Tara; Diller, Lisa

    2003-03-01

    This study examined the utility of routine psychologic screening in a childhood cancer survivor clinic by evaluating patient acceptance, comparing subjects' symptoms to normative data, examining the utility of specific tests, and identifying risk factors associated with psychological distress. During their annual clinic visit, 101 adult survivors of childhood cancer (median age, 25 years) completed the Symptom Checklist 90 Revised (SCL-90), as well as the Short Form 36 (SF-36), Beck Depression Inventory (BDI), and one additional suicide question. Psychological distress was operationally defined according to the published SCL-90 clinical case rule, classifying subjects with a consistent pattern of symptom elevations as clinical cases. The majority of subjects (80%) completed the screening in less than 30 minutes and reported little (15%) or no (84%) distress. Sixty-four percent believed it would help "very much" or "moderately" in getting to know them, and 35% thought it would help "slightly." On the SCL-90, 32 subjects (31.7%) had a positive screen, indicating significant psychological distress. All subjects with clinically significant symptoms on the BDI and SF-36 Mental Health Scale were cases on the SCL-90 (case-positive). Suicidal symptoms were reported in 13.9% of the sample, all of whom were SCL-90 cases. In a logistic regression model, subjects' dissatisfaction with physical appearance, poor physical health, and treatment with cranial radiation were associated with psychological distress. Results demonstrate that routine psychological screening can be successfully integrated into the cancer survivor clinic and may be effective in identifying those survivors with significant distress who require further evaluation.

  4. Dose Adjustment for Normal Eating (DAFNE) in routine clinical practice: who benefits?

    PubMed

    Keen, A J A; Duncan, E; McKillop-Smith, A; Evans, N D; Gold, A E

    2012-05-01

    To explore the effectiveness of Dose Adjustment for Normal Eating in routine clinical practice in the UK. Participants were 124 adults with Type 1 diabetes who had completed a Dose Adjustment for Normal Eating course. Data were collected before the course and again 1 year later on a variety of biological, psychological and social measures. There were a range of significant benefits consistent with Dose Adjustment for Normal Eating aims, including: better control among those with baseline HbA(1c) ≥ 81 mmol/mol (9.6%) (z = -2.8, P = 0.004); reduced number of participants reporting severe hypoglycaemia (χ² = 4.27, P = 0.039); total eradication of diabetic ketoacidosis (χ² = 4.17, P = 0.041) and lower diabetes-related distress (z = -4.5, P < 0.001). The most deprived of the clinic population were significantly under-represented (χ² = 17.8, P = 0.001) and the levels of clinical depression were unusually low. These results indicate that Dose Adjustment for Normal Eating delivered in routine clinical practice is associated with a range of benefits and that certain clinical and psychosocial characteristics are associated with better outcomes. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.

  5. Implementation of large-scale routine diagnostics using whole slide imaging in Sweden: Digital pathology experiences 2006-2013

    PubMed Central

    Thorstenson, Sten; Molin, Jesper; Lundström, Claes

    2014-01-01

    Recent technological advances have improved the whole slide imaging (WSI) scanner quality and reduced the cost of storage, thereby enabling the deployment of digital pathology for routine diagnostics. In this paper we present the experiences from two Swedish sites having deployed routine large-scale WSI for primary review. At Kalmar County Hospital, the digitization process started in 2006 to reduce the time spent at the microscope in order to improve the ergonomics. Since 2008, more than 500,000 glass slides have been scanned in the routine operations of Kalmar and the neighboring Linköping University Hospital. All glass slides are digitally scanned yet they are also physically delivered to the consulting pathologist who can choose to review the slides on screen, in the microscope, or both. The digital operations include regular remote case reporting by a few hospital pathologists, as well as around 150 cases per week where primary review is outsourced to a private clinic. To investigate how the pathologists choose to use the digital slides, a web-based questionnaire was designed and sent out to the pathologists in Kalmar and Linköping. The responses showed that almost all pathologists think that ergonomics have improved and that image quality was sufficient for most histopathologic diagnostic work. 38 ± 28% of the cases were diagnosed digitally, but the survey also revealed that the pathologists commonly switch back and forth between digital and conventional microscopy within the same case. The fact that two full-scale digital systems have been implemented and that a large portion of the primary reporting is voluntarily performed digitally shows that large-scale digitization is possible today. PMID:24843825

  6. Semantic Technologies for Re-Use of Clinical Routine Data.

    PubMed

    Kreuzthaler, Markus; Martínez-Costa, Catalina; Kaiser, Peter; Schulz, Stefan

    2017-01-01

    Routine patient data in electronic patient records are only partly structured, and an even smaller segment is coded, mainly for administrative purposes. Large parts are only available as free text. Transforming this content into a structured and semantically explicit form is a prerequisite for querying and information extraction. The core of the system architecture presented in this paper is based on SAP HANA in-memory database technology using the SAP Connected Health platform for data integration as well as for clinical data warehousing. A natural language processing pipeline analyses unstructured content and maps it to a standardized vocabulary within a well-defined information model. The resulting semantically standardized patient profiles are used for a broad range of clinical and research application scenarios.

  7. Adiponectin as a routine clinical biomarker.

    PubMed

    Kishida, Ken; Funahashi, Tohru; Shimomura, Iichiro

    2014-01-01

    Adiponectin is a protein synthesized and secreted predominantly by adipocytes into the peripheral blood. However, circulating adiponectin level is inversely related with body weight, especially visceral fat accumulation. The mechanism of this paradoxical relation remains obscure. Low circulating adiponectin concentrations (hypoadiponectinemia; <4 μg/mL) are associated with a variety of diseases, including dysmetabolism (type 2 diabetes, insulin resistance, hypertension, dyslipidemia, metabolic syndrome, hyperuricemia), atherosclerosis (coronary artery disease, stroke, peripheral artery disease), sleep apnea, non-alcoholic fatty liver disease, gastritis and gastro-esophageal reflux disease, inflammatory bowel diseases, pancreatitis, osteoporosis, and cancer (endometrial cancer, postmenopausal breast cancer, leukemia, colon cancer, gastric cancer, prostate cancer). On the other hand, hyperadiponectinemia is associated with cardiac, renal and pulmonary diseases. This review article focuses on the significance of adiponectin as a clinical biomarker of obesity-related diseases. Routine measurement of adiponectin in patients with lifestyle-related diseases is highly recommended. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Non-invasive prenatal testing (NIPT): Europe's first multicenter post-market clinical follow-up study validating the quality in clinical routine.

    PubMed

    Flöck, Anne; Tu, Ngoc-Chi; Rüland, Anna; Holzgreve, Wolfgang; Gembruch, Ulrich; Geipel, Annegret

    2017-11-01

    Non-invasive prenatal tests (NIPT) for the determination of fetal aneuploidies from maternal blood are firmly established in clinical routine. For the first time, the accuracy of an NIPT for the determination of trisomies 21, 18 and 13 in singleton pregnancies was assessed by means of a prospective German-wide multicenter post-market clinical follow-up study, to reliably evaluate the quality in clinical routine. The study covered the indications for testing, the test results, the rate of invasive diagnostics and the pregnancy outcome. 2232 cases were tested for trisomy 21. Of these, 1946 cases were additionally examined for trisomy 18 and 13. Sensitivity and specificity for trisomy 21 (43/43) and for trisomy 13 (2/2) were 100%, for trisomy 18 the sensitivity was 80% (4/5) with a specificity of 99.8%. Three false-positive results for trisomy 18 were observed (FPR 0.15%). The no-call rate was 0.5%. In this subgroup, 27.3% (3/11) aneuploidies were diagnosed. The rate of invasive procedures was 2.6%. NIPT provides a very high quality for the fetal trisomies 21, 13 and 18 in clinical routine. The results support the recommendation that NIPT should be offered after genetic counseling and only in conjunction with a qualified ultrasound examination.

  9. Audit of the autoantibody test, EarlyCDT®-lung, in 1600 patients: an evaluation of its performance in routine clinical practice.

    PubMed

    Jett, James R; Peek, Laura J; Fredericks, Lynn; Jewell, William; Pingleton, William W; Robertson, John F R

    2014-01-01

    EarlyCDT(®)-Lung may enhance detection of early stage lung cancer by aiding physicians in assessing high-risk patients through measurement of biological markers (i.e., autoantibodies). The test's performance characteristics in routine clinical practice were evaluated by auditing clinical outcomes of 1613 US patients deemed at high risk for lung cancer by their physician, who ordered the EarlyCDT-Lung test for their patient. Clinical outcomes for all 1613 patients who provided HIPAA authorization are reported. Clinical data were collected from each patient's treating physician. Pathology reports when available were reviewed for diagnostic classification. Staging was assessed on histology, otherwise on imaging. Six month follow-up for the positives/negatives was 99%/93%. Sixty-one patients (4%) were identified with lung cancer, 25 of whom tested positive by EarlyCDT-Lung (sensitivity=41%). A positive EarlyCDT-Lung test on the current panel was associated with a 5.4-fold increase in lung cancer incidence versus a negative. Importantly, 57% (8/14) of non-small cell lung cancers detected as positive (where stage was known) were stage I or II. EarlyCDT-Lung has been extensively tested and validated in case-control settings and has now been shown in this audit to perform in routine clinical practice as predicted. EarlyCDT-Lung may be a complementary tool to CT for detection of early lung cancer. Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  10. Accuracy of routine magnetic resonance imaging in meniscal and ligamentous injuries of the knee: comparison with arthroscopy

    PubMed Central

    Behairy, Noha H.; Dorgham, Mohsen A.

    2008-01-01

    The aim of this study was to detect the accuracy of routine magnetic resonance imaging (MRI) done in different centres and its agreement with arthroscopy in meniscal and ligamentous injuries of the knee. We prospectively examined 70 patients ranging in age between 22 and 59 years. History taking, plain X-ray, clinical examination, routine MRI and arthroscopy were done for all patients. Sensitivity, specificity, accuracy, positive and negative predictive values, P value and kappa agreement measures were calculated. We found a sensitivity of 47 and 100%, specificity of 95 and 75% and accuracy of 73 and 78.5%, respectively, for the medial and lateral meniscus. A sensitivity of 77.8%, specificity of 100% and accuracy of 94% was noted for the anterior cruciate ligament (ACL). We found good kappa agreements (0.43 and 0.45) for both menisci and excellent agreement (0.84) for the ACL. MRI shows high accuracy and should be used as the primary diagnostic tool for selection of candidates for arthroscopy. Level of evidence: 4. PMID:18506445

  11. Imaging of autoimmune encephalitis--Relevance for clinical practice and hippocampal function.

    PubMed

    Heine, J; Prüss, H; Bartsch, T; Ploner, C J; Paul, F; Finke, C

    2015-11-19

    The field of autoimmune encephalitides associated with antibodies targeting cell-surface antigens is rapidly expanding and new antibodies are discovered frequently. Typical clinical presentations include cognitive deficits, psychiatric symptoms, movement disorders and seizures and the majority of patients respond well to immunotherapy. Pathophysiological mechanisms and clinical features are increasingly recognized and indicate hippocampal dysfunction in most of these syndromes. Here, we review the neuroimaging characteristics of autoimmune encephalitides, including N-methyl-d-aspartate (NMDA) receptor, leucine-rich glioma inactivated 1 (LGI1), contactin-associated protein-like 2 (CASPR2) encephalitis as well as more recently discovered and less frequent forms such as dipeptidyl-peptidase-like protein 6 (DPPX) or glycine receptor encephalitis. We summarize findings of routine magnetic resonance imaging (MRI) investigations as well as (18)F-fluoro-2-deoxy-d-glucose (FDG)-positron emission tomography (PET) and single photon emission tomography (SPECT) imaging and relate these observations to clinical features and disease outcome. We furthermore review results of advanced imaging analyses such as diffusion tensor imaging, volumetric analyses and resting-state functional MRI. Finally, we discuss contributions of these neuroimaging observations to the understanding of the pathophysiology of autoimmune encephalitides. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  12. A New Feedback-Based Method for Parameter Adaptation in Image Processing Routines.

    PubMed

    Khan, Arif Ul Maula; Mikut, Ralf; Reischl, Markus

    2016-01-01

    The parametrization of automatic image processing routines is time-consuming if a lot of image processing parameters are involved. An expert can tune parameters sequentially to get desired results. This may not be productive for applications with difficult image analysis tasks, e.g. when high noise and shading levels in an image are present or images vary in their characteristics due to different acquisition conditions. Parameters are required to be tuned simultaneously. We propose a framework to improve standard image segmentation methods by using feedback-based automatic parameter adaptation. Moreover, we compare algorithms by implementing them in a feedforward fashion and then adapting their parameters. This comparison is proposed to be evaluated by a benchmark data set that contains challenging image distortions in an increasing fashion. This promptly enables us to compare different standard image segmentation algorithms in a feedback vs. feedforward implementation by evaluating their segmentation quality and robustness. We also propose an efficient way of performing automatic image analysis when only abstract ground truth is present. Such a framework evaluates robustness of different image processing pipelines using a graded data set. This is useful for both end-users and experts.

  13. A New Feedback-Based Method for Parameter Adaptation in Image Processing Routines

    PubMed Central

    Mikut, Ralf; Reischl, Markus

    2016-01-01

    The parametrization of automatic image processing routines is time-consuming if a lot of image processing parameters are involved. An expert can tune parameters sequentially to get desired results. This may not be productive for applications with difficult image analysis tasks, e.g. when high noise and shading levels in an image are present or images vary in their characteristics due to different acquisition conditions. Parameters are required to be tuned simultaneously. We propose a framework to improve standard image segmentation methods by using feedback-based automatic parameter adaptation. Moreover, we compare algorithms by implementing them in a feedforward fashion and then adapting their parameters. This comparison is proposed to be evaluated by a benchmark data set that contains challenging image distortions in an increasing fashion. This promptly enables us to compare different standard image segmentation algorithms in a feedback vs. feedforward implementation by evaluating their segmentation quality and robustness. We also propose an efficient way of performing automatic image analysis when only abstract ground truth is present. Such a framework evaluates robustness of different image processing pipelines using a graded data set. This is useful for both end-users and experts. PMID:27764213

  14. Hepatitis B Virus Genotyping: Is the Time Ripe for Routine Clinical Use?

    PubMed Central

    Madan, Kaushal; Tyagi, Pankaj

    2012-01-01

    Hepatitis B is one of the major causes of end-stage liver disease and liver cancer worldwide. A number of host and viral factors influence the disease course and outcomes. One such viral factor is hepatitis B virus (HBV) genotypes. There are eight major HBV genotypes described from various geographic regions of the world. Although direct sequencing appears to be the gold standard for HBV genotyping, it is expensive and laborintensive and therefore cannot be applied for routine clinical use. The newer molecular methods including serotyping have made genotyping easier and simple to apply to large number of samples rapidly. The data collected mainly over the last decade have suggested that HBV genotypes may have a bearing over the natural course of the disease and its response to therapy. This review summarizes the available literature and highlights how genotyping could be incorporated into routine clinical practice in order to improve delivery of care to HBV-infected individuals. PMID:25755425

  15. A retrospective review of performance and utility of routine clinical pelvimetry.

    PubMed

    Blackadar, Charles S; Viera, Anthony J

    2004-01-01

    Some authorities have questioned the utility of performing clinical pelvimetry as part of routine prenatal care. This study determined the frequency with which clinical pelvimetry is still performed at two military hospitals and whether the results of pelvimetry influence the management of labor and delivery. We conducted a retrospective review of prenatal records at two military hospitals. One was an overseas hospital, and one was a family medicine teaching hospital in the United States. The records of 660 pregnant women were reviewed to identify documentation that pelvimetry was performed during prenatal care and whether there was evidence that the physician managing labor and delivery altered management based on pelvimetry results. Seventy percent (461) of the 660 records reviewed had all pelvimetry measurements documented as normal, or the provider had written "good for TOL (trial of labor)," "proven to XX pounds," or similar annotation that pelvimetry was normal. Nine percent (58 records) had no documentation of pelvimetry (pelvimetry section left blank). The remaining 21% (141 charts) had at least one pelvimetry measurement listed as abnormal on the initial prenatal exam. No admission note, progress note, or operative note recorded during labor and delivery made reference to clinical pelvimetry results. No abnormal pelvimetry result was referenced in follow-up visits or appeared to make any difference in mode of delivery or treatment in labor. Two women (one at each institution) had initial visit notes indicating the need to consider radiographic pelvimetry based on the results of clinical exam, but this test was not done in either case, and both women delivered vaginally. Our study indicates that clinical pelvimetry does not change management of pregnant patients. Current practice is to allow all women a trial of labor regardless of pelvimetry results. This makes the routine performance and recording of clinical pelvimetry a waste of time, a potential

  16. Generalized whole-body Patlak parametric imaging for enhanced quantification in clinical PET.

    PubMed

    Karakatsanis, Nicolas A; Zhou, Yun; Lodge, Martin A; Casey, Michael E; Wahl, Richard L; Zaidi, Habib; Rahmim, Arman

    2015-11-21

    We recently developed a dynamic multi-bed PET data acquisition framework to translate the quantitative benefits of Patlak voxel-wise analysis to the domain of routine clinical whole-body (WB) imaging. The standard Patlak (sPatlak) linear graphical analysis assumes irreversible PET tracer uptake, ignoring the effect of FDG dephosphorylation, which has been suggested by a number of PET studies. In this work: (i) a non-linear generalized Patlak (gPatlak) model is utilized, including a net efflux rate constant kloss, and (ii) a hybrid (s/g)Patlak (hPatlak) imaging technique is introduced to enhance contrast to noise ratios (CNRs) of uptake rate Ki images. Representative set of kinetic parameter values and the XCAT phantom were employed to generate realistic 4D simulation PET data, and the proposed methods were additionally evaluated on 11 WB dynamic PET patient studies. Quantitative analysis on the simulated Ki images over 2 groups of regions-of-interest (ROIs), with low (ROI A) or high (ROI B) true kloss relative to Ki, suggested superior accuracy for gPatlak. Bias of sPatlak was found to be 16-18% and 20-40% poorer than gPatlak for ROIs A and B, respectively. By contrast, gPatlak exhibited, on average, 10% higher noise than sPatlak. Meanwhile, the bias and noise levels for hPatlak always ranged between the other two methods. In general, hPatlak was seen to outperform all methods in terms of target-to-background ratio (TBR) and CNR for all ROIs. Validation on patient datasets demonstrated clinical feasibility for all Patlak methods, while TBR and CNR evaluations confirmed our simulation findings, and suggested presence of non-negligible kloss reversibility in clinical data. As such, we recommend gPatlak for highly quantitative imaging tasks, while, for tasks emphasizing lesion detectability (e.g. TBR, CNR) over quantification, or for high levels of noise, hPatlak is instead preferred. Finally, gPatlak and hPatlak CNR was systematically higher compared to routine SUV

  17. Generalized whole-body Patlak parametric imaging for enhanced quantification in clinical PET

    NASA Astrophysics Data System (ADS)

    Karakatsanis, Nicolas A.; Zhou, Yun; Lodge, Martin A.; Casey, Michael E.; Wahl, Richard L.; Zaidi, Habib; Rahmim, Arman

    2015-11-01

    We recently developed a dynamic multi-bed PET data acquisition framework to translate the quantitative benefits of Patlak voxel-wise analysis to the domain of routine clinical whole-body (WB) imaging. The standard Patlak (sPatlak) linear graphical analysis assumes irreversible PET tracer uptake, ignoring the effect of FDG dephosphorylation, which has been suggested by a number of PET studies. In this work: (i) a non-linear generalized Patlak (gPatlak) model is utilized, including a net efflux rate constant kloss, and (ii) a hybrid (s/g)Patlak (hPatlak) imaging technique is introduced to enhance contrast to noise ratios (CNRs) of uptake rate Ki images. Representative set of kinetic parameter values and the XCAT phantom were employed to generate realistic 4D simulation PET data, and the proposed methods were additionally evaluated on 11 WB dynamic PET patient studies. Quantitative analysis on the simulated Ki images over 2 groups of regions-of-interest (ROIs), with low (ROI A) or high (ROI B) true kloss relative to Ki, suggested superior accuracy for gPatlak. Bias of sPatlak was found to be 16-18% and 20-40% poorer than gPatlak for ROIs A and B, respectively. By contrast, gPatlak exhibited, on average, 10% higher noise than sPatlak. Meanwhile, the bias and noise levels for hPatlak always ranged between the other two methods. In general, hPatlak was seen to outperform all methods in terms of target-to-background ratio (TBR) and CNR for all ROIs. Validation on patient datasets demonstrated clinical feasibility for all Patlak methods, while TBR and CNR evaluations confirmed our simulation findings, and suggested presence of non-negligible kloss reversibility in clinical data. As such, we recommend gPatlak for highly quantitative imaging tasks, while, for tasks emphasizing lesion detectability (e.g. TBR, CNR) over quantification, or for high levels of noise, hPatlak is instead preferred. Finally, gPatlak and hPatlak CNR was systematically higher compared to routine SUV

  18. Preanalytical management: serum vacuum tubes validation for routine clinical chemistry.

    PubMed

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2012-01-01

    The validation process is essential in accredited clinical laboratories. Aim of this study was to validate five kinds of serum vacuum tubes for routine clinical chemistry laboratory testing. Blood specimens from 100 volunteers in five different serum vacuum tubes (Tube I: VACUETTE, Tube II: LABOR IMPORT, Tube III: S-Monovette, Tube IV: SST and Tube V: SST II) were collected by a single, expert phlebotomist. The routine clinical chemistry tests were analyzed on cobas 6000 module. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.005. Finally, the biases from Tube I, Tube II, Tube III, Tube IV and Tube V were compared with the current desirable quality specifications for bias (B), derived from biological variation. Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according him/her technical or economical reasons, in order to perform the following laboratory tests: glucose, total cholesterol, high density lipoprotein-cholesterol, triglycerides, total protein, albumin, blood urea nitrogen, uric acid, alkaline phosphatise, aspartate aminotransferase, gamma-glutamyltransferase, lactate dehydrogenase, creatine kinase, total bilirubin, direct bilirubin, calcium, iron, sodium and potassium. On the contrary special attention will be required if the laboratory already performs creatinine, amylase, phosphate and magnesium determinations and the quality laboratory manager intend to change the serum tubes. We suggest that laboratory management should both standardize the procedures and frequently evaluate the quality of in vitro diagnostic devices.

  19. Hospital integrated parallel cluster for fast and cost-efficient image analysis: clinical experience and research evaluation

    NASA Astrophysics Data System (ADS)

    Erberich, Stephan G.; Hoppe, Martin; Jansen, Christian; Schmidt, Thomas; Thron, Armin; Oberschelp, Walter

    2001-08-01

    In the last few years more and more University Hospitals as well as private hospitals changed to digital information systems for patient record, diagnostic files and digital images. Not only that patient management becomes easier, it is also very remarkable how clinical research can profit from Picture Archiving and Communication Systems (PACS) and diagnostic databases, especially from image databases. Since images are available on the finger tip, difficulties arise when image data needs to be processed, e.g. segmented, classified or co-registered, which usually demands a lot computational power. Today's clinical environment does support PACS very well, but real image processing is still under-developed. The purpose of this paper is to introduce a parallel cluster of standard distributed systems and its software components and how such a system can be integrated into a hospital environment. To demonstrate the cluster technique we present our clinical experience with the crucial but cost-intensive motion correction of clinical routine and research functional MRI (fMRI) data, as it is processed in our Lab on a daily basis.

  20. Routine operation of an Elliott 903 computer in a clinical chemistry laboratory

    PubMed Central

    Whitby, L. G.; Simpson, D.

    1973-01-01

    Experience gained in the last four years concerning the capabilities and limitations of an 8K Elliott 903 (18-bit word) computer with magnetic tape backing store in the routine operation of a clinical chemistry laboratory is described. Designed as a total system, routine operation has latterly had to be confined to data acquisition and process control functions, due primarily to limitations imposed by the choice of hardware early in the project. In this final report of a partially successful experiment the opportunity is taken to review mistakes made, especially at the start of the project, to warn potential computer users of pitfalls to be avoided. PMID:4580240

  1. Rapid targeted somatic mutation analysis of solid tumors in routine clinical diagnostics.

    PubMed

    Magliacane, Gilda; Grassini, Greta; Bartocci, Paola; Francaviglia, Ilaria; Dal Cin, Elena; Barbieri, Gianluca; Arrigoni, Gianluigi; Pecciarini, Lorenza; Doglioni, Claudio; Cangi, Maria Giulia

    2015-10-13

    Tumor genotyping is an essential step in routine clinical practice and pathology laboratories face a major challenge in being able to provide rapid, sensitive and updated molecular tests. We developed a novel mass spectrometry multiplexed genotyping platform named PentaPanel to concurrently assess single nucleotide polymorphisms in 56 hotspots of the 5 most clinically relevant cancer genes, KRAS, NRAS, BRAF, EGFR and PIK3CA for a total of 221 detectable mutations. To both evaluate and validate the PentaPanel performance, we investigated 1025 tumor specimens of 6 different cancer types (carcinomas of colon, lung, breast, pancreas, and biliary tract, and melanomas), systematically addressing sensitivity, specificity, and reproducibility of our platform. Sanger sequencing was also performed for all the study samples. Our data showed that PentaPanel is a high throughput and robust tool, allowing genotyping for targeted therapy selection of 10 patients in the same run, with a practical turnaround time of 2 working days. Importantly, it was successfully used to interrogate different DNAs isolated from routinely processed specimens (formalin-fixed paraffin embedded, frozen, and cytological samples), covering all the requirements of clinical tests. In conclusion, the PentaPanel platform can provide an immediate, accurate and cost effective multiplex approach for clinically relevant gene mutation analysis in many solid tumors and its utility across many diseases can be particularly relevant in multiple clinical trials, including the new basket trial approach, aiming to identify appropriate targeted drug combination strategies.

  2. Computer-aided diagnosis and artificial intelligence in clinical imaging.

    PubMed

    Shiraishi, Junji; Li, Qiang; Appelbaum, Daniel; Doi, Kunio

    2011-11-01

    Computer-aided diagnosis (CAD) is rapidly entering the radiology mainstream. It has already become a part of the routine clinical work for the detection of breast cancer with mammograms. The computer output is used as a "second opinion" in assisting radiologists' image interpretations. The computer algorithm generally consists of several steps that may include image processing, image feature analysis, and data classification via the use of tools such as artificial neural networks (ANN). In this article, we will explore these and other current processes that have come to be referred to as "artificial intelligence." One element of CAD, temporal subtraction, has been applied for enhancing interval changes and for suppressing unchanged structures (eg, normal structures) between 2 successive radiologic images. To reduce misregistration artifacts on the temporal subtraction images, a nonlinear image warping technique for matching the previous image to the current one has been developed. Development of the temporal subtraction method originated with chest radiographs, with the method subsequently being applied to chest computed tomography (CT) and nuclear medicine bone scans. The usefulness of the temporal subtraction method for bone scans was demonstrated by an observer study in which reading times and diagnostic accuracy improved significantly. An additional prospective clinical study verified that the temporal subtraction image could be used as a "second opinion" by radiologists with negligible detrimental effects. ANN was first used in 1990 for computerized differential diagnosis of interstitial lung diseases in CAD. Since then, ANN has been widely used in CAD schemes for the detection and diagnosis of various diseases in different imaging modalities, including the differential diagnosis of lung nodules and interstitial lung diseases in chest radiography, CT, and position emission tomography/CT. It is likely that CAD will be integrated into picture archiving and

  3. Imaging and Analytics: The changing face of Medical Imaging

    NASA Astrophysics Data System (ADS)

    Foo, Thomas

    There have been significant technological advances in imaging capability over the past 40 years. Medical imaging capabilities have developed rapidly, along with technology development in computational processing speed and miniaturization. Moving to all-digital, the number of images that are acquired in a routine clinical examination has increased dramatically from under 50 images in the early days of CT and MRI to more than 500-1000 images today. The staggering number of images that are routinely acquired poses significant challenges for clinicians to interpret the data and to correctly identify the clinical problem. Although the time provided to render a clinical finding has not substantially changed, the amount of data available for interpretation has grown exponentially. In addition, the image quality (spatial resolution) and information content (physiologically-dependent image contrast) has also increased significantly with advances in medical imaging technology. On its current trajectory, medical imaging in the traditional sense is unsustainable. To assist in filtering and extracting the most relevant data elements from medical imaging, image analytics will have a much larger role. Automated image segmentation, generation of parametric image maps, and clinical decision support tools will be needed and developed apace to allow the clinician to manage, extract and utilize only the information that will help improve diagnostic accuracy and sensitivity. As medical imaging devices continue to improve in spatial resolution, functional and anatomical information content, image/data analytics will be more ubiquitous and integral to medical imaging capability.

  4. Whole-slide imaging: routine pathologic diagnosis.

    PubMed

    Cornish, Toby C; Swapp, Ryan E; Kaplan, Keith J

    2012-05-01

    Digital pathology systems offer pathologists an alternate, emerging mechanism to manage and interpret information. They offer increasingly fast and scalable hardware platforms for slide scanning and software that facilitates remote viewing, slide conferencing, archiving, and image analysis. Deployed initially and validated largely within the research and biopharmaceutical industries, WSI is increasingly being implemented for direct patient care. Improvements in image quality, scan times, and imageviewing browsers will hopefully allow pathologists to more seamlessly convert to digital pathology, much like our radiology colleagues have done before us. However, WSI creates both opportunities and challenges. Although niche applications of WSI technology for clinical, educational, and research purposes are clearly successful, it is evident that several areas still require attention and careful consideration before more widespread clinical adoption of WSI takes place. These include regulatory issues, development of standards of practice and validation guidelines, workflow modifications, as well as defining situations where WSI technology will really improve practice in a cost-effective way. Current progress on these and other issues, along with improving technology, will no doubt pave the way for increased adoption over the next decade, allowing the pathology community as a whole to harness the true potential of WSI for patient care. The digital decade will likely redefine how pathology is practiced and the role of the pathologist.

  5. Clinical brain MR imaging prescriptions in Talairach space: technologist- and computer-driven methods.

    PubMed

    Weiss, Kenneth L; Pan, Hai; Storrs, Judd; Strub, William; Weiss, Jane L; Jia, Li; Eldevik, O Petter

    2003-05-01

    Variability in patient head positioning may yield substantial interstudy image variance in the clinical setting. We describe and test three-step technologist and computer-automated algorithms designed to image the brain in a standard reference system and reduce variance. Triple oblique axial images obtained parallel to the Talairach anterior commissure (AC)-posterior commissure (PC) plane were reviewed in a prospective analysis of 126 consecutive patients. Requisite roll, yaw, and pitch correction, as three authors determined independently and subsequently by consensus, were compared with the technologists' actual graphical prescriptions and those generated by a novel computer automated three-step (CATS) program. Automated pitch determinations generated with Statistical Parametric Mapping '99 (SPM'99) were also compared. Requisite pitch correction (15.2 degrees +/- 10.2 degrees ) far exceeded that for roll (-0.6 degrees +/- 3.7 degrees ) and yaw (-0.9 degrees +/- 4.7 degrees ) in terms of magnitude and variance (P <.001). Technologist and computer-generated prescriptions substantially reduced interpatient image variance with regard to roll (3.4 degrees and 3.9 degrees vs 13.5 degrees ), yaw (0.6 degrees and 2.5 degrees vs 22.3 degrees ), and pitch (28.6 degrees, 18.5 degrees with CATS, and 59.3 degrees with SPM'99 vs 104 degrees ). CATS performed worse than the technologists in yaw prescription, and it was equivalent in roll and pitch prescriptions. Talairach prescriptions better approximated standard CT canthomeatal angulations (9 degrees vs 24 degrees ) and provided more efficient brain coverage than that of routine axial imaging. Brain MR prescriptions corrected for direct roll, yaw, and Talairach AC-PC pitch can be readily achieved by trained technologists or automated computer algorithms. This ability will substantially reduce interpatient variance, allow better approximation of standard CT angulation, and yield more efficient brain coverage than that of

  6. The Quality of Clinical Maternal and Neonatal Healthcare – A Strategy for Identifying ‘Routine Care Signal Functions’

    PubMed Central

    Brenner, Stephan; De Allegri, Manuela; Gabrysch, Sabine; Chinkhumba, Jobiba; Sarker, Malabika; Muula, Adamson S.

    2015-01-01

    Background A variety of clinical process indicators exists to measure the quality of care provided by maternal and neonatal health (MNH) programs. To allow comparison across MNH programs in low- and middle-income countries (LMICs), a core set of essential process indicators is needed. Although such a core set is available for emergency obstetric care (EmOC), the ‘EmOC signal functions’, a similar approach is currently missing for MNH routine care evaluation. We describe a strategy for identifying core process indicators for routine care and illustrate their usefulness in a field example. Methods We first developed an indicator selection strategy by combining epidemiological and programmatic aspects relevant to MNH in LMICs. We then identified routine care process indicators meeting our selection criteria by reviewing existing quality of care assessment protocols. We grouped these indicators into three categories based on their main function in addressing risk factors of maternal or neonatal complications. We then tested this indicator set in a study assessing MNH quality of clinical care in 33 health facilities in Malawi. Results Our strategy identified 51 routine care processes: 23 related to initial patient risk assessment, 17 to risk monitoring, 11 to risk prevention. During the clinical performance assessment a total of 82 cases were observed. Birth attendants’ adherence to clinical standards was lowest in relation to risk monitoring processes. In relation to major complications, routine care processes addressing fetal and newborn distress were performed relatively consistently, but there were major gaps in the performance of routine care processes addressing bleeding, infection, and pre-eclampsia risks. Conclusion The identified set of process indicators could identify major gaps in the quality of obstetric and neonatal care provided during the intra- and immediate postpartum period. We hope our suggested indicators for essential routine care processes

  7. Echocardiographic and Fluoroscopic Fusion Imaging for Procedural Guidance: An Overview and Early Clinical Experience.

    PubMed

    Thaden, Jeremy J; Sanon, Saurabh; Geske, Jeffrey B; Eleid, Mackram F; Nijhof, Niels; Malouf, Joseph F; Rihal, Charanjit S; Bruce, Charles J

    2016-06-01

    There has been significant growth in the volume and complexity of percutaneous structural heart procedures in the past decade. Increasing procedural complexity and accompanying reliance on multimodality imaging have fueled the development of fusion imaging to facilitate procedural guidance. The first clinically available system capable of echocardiographic and fluoroscopic fusion for real-time guidance of structural heart procedures was approved by the US Food and Drug Administration in 2012. Echocardiographic-fluoroscopic fusion imaging combines the precise catheter and device visualization of fluoroscopy with the soft tissue anatomy and color flow Doppler information afforded by echocardiography in a single image. This allows the interventionalist to perform precise catheter manipulations under fluoroscopy guidance while visualizing critical tissue anatomy provided by echocardiography. However, there are few data available addressing this technology's strengths and limitations in routine clinical practice. The authors provide a critical review of currently available echocardiographic-fluoroscopic fusion imaging for guidance of structural heart interventions to highlight its strengths, limitations, and potential clinical applications and to guide further research into value of this emerging technology. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  8. Routine clinical heart examinations using SQUID magnetocardiography at University of Tsukuba Hospital

    NASA Astrophysics Data System (ADS)

    Inaba, T.; Nakazawa, Y.; Yoshida, K.; Kato, Y.; Hattori, A.; Kimura, T.; Hoshi, T.; Ishizu, T.; Seo, Y.; Sato, A.; Sekiguchi, Y.; Nogami, A.; Watanabe, S.; Horigome, H.; Kawakami, Y.; Aonuma, K.

    2017-11-01

    A 64-channel Nb-based DC-SQUID magnetocardiography (MCG) system was installed at the University of Tsukuba Hospital (UTH) in March 2007 after obtaining Japanese pharmaceutical approval and insurance reimbursement approval. In the period between 2008 and 2016, the total number of patients was 10 085. The heart diseases diagnosed in fetuses as well as adults are mainly atrial arrhythmia, abnormal repolarization, ventricular arrhythmia, and fetal arrhythmia. In most cases of insufficient diagnostic accuracy with electrocardiography, SQUID MCG precisely revealed these heart diseases as an abnormal electrical current distribution. Based on success in routine examinations, SQUID MCG is now an indispensable clinical instrument with diagnostic software tuned up during routine use at UTH.

  9. Preanalytical management: serum vacuum tubes validation for routine clinical chemistry

    PubMed Central

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2012-01-01

    Introduction The validation process is essential in accredited clinical laboratories. Aim of this study was to validate five kinds of serum vacuum tubes for routine clinical chemistry laboratory testing. Materials and methods: Blood specimens from 100 volunteers in five diff erent serum vacuum tubes (Tube I: VACUETTE®, Tube II: LABOR IMPORT®, Tube III: S-Monovette®, Tube IV: SST® and Tube V: SST II®) were collected by a single, expert phlebotomist. The routine clinical chemistry tests were analyzed on cobas® 6000 module. The significance of the diff erences between samples was assessed by paired Student’s t-test after checking for normality. The level of statistical significance was set at P < 0.005. Finally, the biases from Tube I, Tube II, Tube III, Tube IV and Tube V were compared with the current desirable quality specifications for bias (B), derived from biological variation. Results and conclusions: Basically, our validation will permit the laboratory or hospital managers to select the brand’s vacuum tubes validated according him/her technical or economical reasons, in order to perform the following laboratory tests: glucose, total cholesterol, high density lipoprotein-cholesterol, triglycerides, total protein, albumin, blood urea nitrogen, uric acid, alkaline phosphatise, aspartate aminotransferase, gamma-glutamyltransferase, lactate dehydrogenase, creatine kinase, total bilirubin, direct bilirubin, calcium, iron, sodium and potassium. On the contrary special attention will be required if the laboratory already performs creatinine, amylase, phosphate and magnesium determinations and the quality laboratory manager intend to change the serum tubes. We suggest that laboratory management should both standardize the procedures and frequently evaluate the quality of in vitro diagnostic devices. PMID:22838184

  10. A new vestibulo-ocular reflex recording system designed for routine vestibular clinical use.

    PubMed

    Funabiki, K; Naito, Y; Matsuda, K; Honjo, I

    1999-01-01

    A new vestibulo-ocular reflex (VOR) recording system was developed, which consists of an infrared eye camera, a small velocity sensor and a frequency modulator. Using this system, the head velocity signal was frequency modulated and simultaneously recorded as a sound signal on the audio track of a Hi8 video recorder with eye images. This device enabled recording of the VOR response in routine vestibular clinical practice. The reliability and effectiveness of this system were estimated by recording and analysing the VOR response against manually controlled rotation in normal subjects (n = 22) and in patients with unilateral severe vestibular hypofunction (n = 11). VOR gain on clockwise rotation viewed from the top was defined as R gain, and counterclockwise rotation as L gain. Directional preponderance (DP%) was also calculated. VOR gain towards the diseased side was significantly lower than that towards the intact side, and also significantly lower than that of normal subjects. DP% of unilateral vestibular hypofunction cases was significantly larger than that of normal subjects. These findings indicate that this VOR recording system reliably detects severe unilateral vestibular hypofunction.

  11. Cardiovascular Magnetic Resonance in Cardiology Practice: A Concise Guide to Image Acquisition and Clinical Interpretation.

    PubMed

    Valbuena-López, Silvia; Hinojar, Rocío; Puntmann, Valentina O

    2016-02-01

    Cardiovascular magnetic resonance plays an increasingly important role in routine cardiology clinical practice. It is a versatile imaging modality that allows highly accurate, broad and in-depth assessment of cardiac function and structure and provides information on pertinent clinical questions in diseases such as ischemic heart disease, nonischemic cardiomyopathies, and heart failure, as well as allowing unique indications, such as the assessment and quantification of myocardial iron overload or infiltration. Increasing evidence for the role of cardiovascular magnetic resonance, together with the spread of knowledge and skill outside expert centers, has afforded greater access for patients and wider clinical experience. This review provides a snapshot of cardiovascular magnetic resonance in modern clinical practice by linking image acquisition and postprocessing with effective delivery of the clinical meaning. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  12. Clinical significance of duodenal lymphangiectasia incidentally found during routine upper gastrointestinal endoscopy.

    PubMed

    Kim, J H; Bak, Y T; Kim, J S; Seol, S Y; Shin, B K; Kim, H K

    2009-06-01

    Although duodenal lymphangiectasia in individuals without clinical evidence of malabsorption has been reported, the prevalence and clinical significance in this situation are not yet known. The aim of this study was to evaluate the prevalence and clinical significance of incidentally found duodenal lymphangiectasia. A retrospective review of medical records was undertaken for consecutive patients who had undergone diagnostic upper endoscopy between January 2005 and June 2006. A prospective study was then performed in consecutive individuals undergoing routine upper endoscopy for health examination between July 2006 to October 2006. Endoscopic features of duodenal lymphangiectasia were classified into three types: (1) multiple scattered pinpoint white spots; (2) diffuse prominent villi with whitish-discolored tips; and (3) focal small whitish macule or nodule. The histologic grade of duodenal lymphangiectasia was classified according to the depth and severity of lymphatic duct dilatations. Prevalence and clinical data of incidentally found duodenal lymphangiectasia were evaluated in the retrospective and prospective studies. Among 1866 retrospective cases, duodenal lymphangiectasia was endoscopically suspected in 59 cases (3.2%), and histologically confirmed in 35 cases (1.9%). No clinical evidence of malabsorption was noted in the duodenal lymphangiectasia cases. The "scattered pinpoint white spots" type was the most frequently found endoscopic feature (40.0%). Duodenal lymphangiectasia was persistent in seven of 10 individuals who underwent repeat endoscopy after a median of 12 months. Among 134 prospective cases, duodenal lymphangiectasia was histologically confirmed in 12 cases (8.9%). There was no significant clinical difference between groups with and without duodenal lymphangiectasia. Lymphatic duct dilatation was histologically more severe in the "focal small whitish macule or nodule" type than in the other types. Duodenal lymphangiectasia without clinical

  13. The clinical value of daily routine chest radiographs in a mixed medical-surgical intensive care unit is low.

    PubMed

    Graat, Marleen E; Choi, Goda; Wolthuis, Esther K; Korevaar, Johanna C; Spronk, Peter E; Stoker, Jaap; Vroom, Margreeth B; Schultz, Marcus J

    2006-02-01

    The clinical value of daily routine chest radiographs (CXRs) in critically ill patients is unknown. We conducted this study to evaluate how frequently unexpected predefined major abnormalities are identified with daily routine CXRs, and how often these findings lead to a change in care for intensive care unit (ICU) patients. This was a prospective observational study conducted in a 28-bed, mixed medical-surgical ICU of a university hospital. Over a 5-month period, 2,457 daily routine CXRs were done in 754 consecutive ICU patients. The majority of these CXRs did not reveal any new predefined major finding. In only 5.8% of daily routine CXRs (14.3% of patients) was one or more new and unexpected abnormality encountered, including large atelectases (24 times in 20 patients), large infiltrates (23 in 22), severe pulmonary congestion (29 in 25), severe pleural effusion (13 in 13), pneumothorax/pneumomediastinum (14 in 13), and malposition of the orotracheal tube (32 in 26). Fewer than half of the CXRs with a new and unexpected finding were ultimately clinically relevant; in only 2.2% of all daily routine CXRs (6.4% of patients) did these radiologic abnormalities result in a change to therapy. Subgroup analysis revealed no differences between medical and surgical patients with regard to the incidence of new and unexpected findings on daily routine CXRs and the effect of new and unexpected CXR findings on daily care. In the ICU, daily routine CXRs seldom reveal unexpected, clinically relevant abnormalities, and they rarely prompt action. We propose that this diagnostic examination be abandoned in ICU patients.

  14. Challenges and opportunities in clinical translation of biomedical optical spectroscopy and imaging

    NASA Astrophysics Data System (ADS)

    Wilson, Brian C.; Jermyn, Michael; Leblond, Frederic

    2018-03-01

    Medical devices face many hurdles before they enter routine clinical practice to address unmet clinical needs. This is also the case for biomedical optical spectroscopy and imaging systems that are used here to illustrate the opportunities and challenges involved. Following initial concept, stages in clinical translation include instrument development, preclinical testing, clinical prototyping, clinical trials, prototype-to-product conversion, regulatory approval, commercialization, and finally clinical adoption and dissemination, all in the face of potentially competing technologies. Optical technologies face additional challenges from their being extremely diverse, often targeting entirely different diseases and having orders-of-magnitude differences in resolution and tissue penetration. However, these technologies can potentially address a wide variety of unmet clinical needs since they provide rich intrinsic biochemical and structural information, have high sensitivity and specificity for disease detection and localization, and are practical, safe (minimally invasive, nonionizing), and relatively affordable.

  15. Routine Computer Tomography Imaging for the Detection of Recurrences in High-Risk Melanoma Patients.

    PubMed

    Park, Tristen S; Phan, Giao Q; Yang, James C; Kammula, Udai; Hughes, Marybeth S; Trebska-McGowan, Kasia; Morton, Kathleen E; White, Donald E; Rosenberg, Steven A; Sherry, Richard M

    2017-04-01

    The use of routine CT imaging for surveillance in asymptomatic patients with cutaneous melanoma is controversial. We report our experience using a surveillance strategy that included CT imaging for a cohort of patients with high-risk melanoma. A total of 466 patients with high-risk cutaneous melanoma enrolled in adjuvant immunotherapy trials were followed for tumor progression by physical examination, labs, and CT imaging as defined by protocol. Evaluations were obtained at least every 6 months for year 1, every 6 months for year 2, and then annually for the remainder of the 5-year study. Time to tumor progression, sites of recurrence, and the method of relapse detection were identified. The patient cohort consisted of 115 stage II patients, 328 stage III patients, and 23 patients with resected stage IV melanoma. The medium time to progression for the 225 patients who developed tumor progression was 7 months. Tumor progression was detected by patients, physician examination or routine labs, or by CT imaging alone in 27, 14, and 59% of cases respectively. Melanoma recurrences were noted to be locoregional in 36% of cases and systemic in 64% of cases. Thirty percent of patients with locoregional relapse and 75% of patients with systemic relapse were detected solely by CT imaging. CT imaging alone detected the majority of sites of disease progression in our patients with high-risk cutaneous melanoma. This disease was not heralded by symptoms, physical examination, or blood work. Although the benefit of the early detection of advanced melanoma is unknown, this experience is relevant because of the rapid development and availability of potentially curative immunotherapies.

  16. Use of structured musculoskeletal examination routines in undergraduate medical education and postgraduate clinical practice - a UK survey.

    PubMed

    Baker, Kenneth F; Jandial, Sharmila; Thompson, Ben; Walker, David; Taylor, Ken; Foster, Helen E

    2016-10-21

    Structured examination routines have been developed as educational resources for musculoskeletal clinical skills teaching, including Gait-Arms-Legs-Spine (GALS), Regional Examination of the Musculoskeletal System (REMS) and paediatric GALS (pGALS). In this study, we aimed to assess the awareness and use of these examination routines in undergraduate medical teaching in UK medical schools and UK postgraduate clinical practice. Electronic questionnaires were distributed to adult and paediatric musculoskeletal teaching leads at UK medical schools and current UK doctors in training. Responses were received from 67 tutors representing teaching at 22/33 [67 %] of all UK medical schools, and 70 trainee doctors across a range of postgraduate training specialities. There was widespread adoption, at responding medical schools, of the adult examination routines within musculoskeletal teaching (GALS: 14/16 [88 %]; REMS: 12/16 [75 %]) and assessment (GALS: 13/16 [81 %]; REMS: 12/16 [75 %]). More trainees were aware of GALS (64/70 [91 %]) than REMS (14/67 [21 %]). Of the 39 trainees who used GALS in their clinical practice, 35/39 [90 %] reported that it had improved their confidence in musculoskeletal examination. Of the 17/22 responding medical schools that included paediatric musculoskeletal examination within their curricula, 15/17 [88 %] used the pGALS approach and this was included within student assessment at 4 medical schools. We demonstrate the widespread adoption of these examination routines in undergraduate education and significant uptake in postgraduate clinical practice. Further study is required to understand their impact upon clinical performance.

  17. Externally Acquired Radiological Data for the Clinical Routine - A Review of the Reimbursement Situation in Germany.

    PubMed

    Schreyer, Andreas G; Steinhäuser, René T; Rosenberg, Britta

    2018-02-07

     Interdisciplinary radiological conferences and boards can improve therapeutic pathways. Because of the reinterpretation and presentation of external image data, which already was read, an additional workload is created which is currently not considered by health care providers. In this review we discuss the ongoing basics and possibilities in health economy for a radiological second opinion for the outpatient and inpatient sector in Germany.  Based on up-to-date literature and jurisdiction, we discuss the most important questions for the reimbursement for second opinions and conference presentations of external image data in an FAQ format. Additionally, we focus on the recently introduced E-Health law accordingly.  Radiological services considering second opinion or board presentation of externally acquired image data are currently not adequately covered by health care providers. In particular, there is no reimbursement possibility for the inpatient sector. Only patients with private insurance or privately paid second opinions can be charged when these patients visit the radiologist directly.  Currently there is no adequate reimbursement possibility for a radiological second opinion or image demonstrations in clinical conferences. It will be essential to integrate adequate reimbursement by health care providers in the near future because of the importance of radiology as an essential diagnostic and therapeutic medical partner.   · Currently there is no reimbursement for image interpretation and presentation in boards.. · Second opinions can only be reimbursed for patients with private insurance or privately recompensed.. · The E-Health law allows reimbursement for tele-counsel in very complex situations.. · It will be crucial to integrate radiological second opinion in future reimbursement policies by health care providers.. · Schreyer AG, Steinhäuser RT, Rosenberg B. Externally Acquired Radiological Data for the Clinical Routine - A Review of

  18. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    NASA Astrophysics Data System (ADS)

    Gaona, Enrique; Alfonso, Beatriz Y. Álvarez; Castellanos, Gustavo Casian; Enríquez, Jesús Gabriel Franco

    2008-08-01

    The goal of the study was to evaluate the first CR digital mammography system (® Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.

  19. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez

    2008-08-11

    The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CRmore » Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.« less

  20. Quantitative echocardiographic measures in the assessment of single ventricle function post-Fontan: Incorporation into routine clinical practice.

    PubMed

    Rios, Rodrigo; Ginde, Salil; Saudek, David; Loomba, Rohit S; Stelter, Jessica; Frommelt, Peter

    2017-01-01

    Quantitative echocardiographic measurements of single ventricular (SV) function have not been incorporated into routine clinical practice. A clinical protocol, which included quantitative measurements of SV deformation (global circumferential and longitudinal strain and strain rate), standard deviation of time to peak systolic strain, myocardial performance index (MPI), dP/dT from an atrioventricular valve regurgitant jet, and superior mesenteric artery resistance index, was instituted for all patients with a history of Fontan procedure undergoing echocardiography. All measures were performed real time during clinically indicated studies and were included in clinical reports. A total of 100 consecutive patients (mean age = 11.95±6.8 years, range 17 months-31.3 years) completed the protocol between September 1, 2014 to April 29, 2015. Deformation measures were completed in 100% of the studies, MPI in 93%, dP/dT in 55%, and superior mesenteric artery Doppler in 82%. The studies were reviewed to assess for efficiency in completing the protocol. The average time for image acquisition was 27.4±8.8 (range 10-62 minutes). The average time to perform deformation measures was 10.8±5.5 minutes (range 5-35 minutes) and time from beginning of imaging to report completion was 53.4±13.7 minutes (range 27-107 minutes). There was excellent inter-observer reliability when deformation indices were blindly repeated. Patients with a single left ventricle had significantly higher circumferential strain and strain rate, longitudinal strain and strain rate, and dP/dT compared to a single right ventricle. There were no differences in quantitative indices of ventricular function between patients <10 vs. >10 years post-Fontan. Advanced quantitative assessment of SV function post-Fontan can be consistently and efficiently performed real time during clinically indicated echocardiograms with excellent reliability. © 2016, Wiley Periodicals, Inc.

  1. Evaluation of the articular cartilage of the knee joint: value of adding a T2 mapping sequence to a routine MR imaging protocol.

    PubMed

    Kijowski, Richard; Blankenbaker, Donna G; Munoz Del Rio, Alejandro; Baer, Geoffrey S; Graf, Ben K

    2013-05-01

    To determine whether the addition of a T2 mapping sequence to a routine magnetic resonance (MR) imaging protocol could improve diagnostic performance in the detection of surgically confirmed cartilage lesions within the knee joint at 3.0 T. This prospective study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The study group consisted of 150 patients (76 male and 74 female patients with an average age of 41.2 and 41.5 years, respectively) who underwent MR imaging and arthroscopy of the knee joint. MR imaging was performed at 3.0 T by using a routine protocol with the addition of a sagittal T2 mapping sequence. Images from all MR examinations were reviewed in consensus by two radiologists before surgery to determine the presence or absence of cartilage lesions on each articular surface, first by using the routine MR protocol alone and then by using the routine MR protocol with T2 maps. Each articular surface was then evaluated at arthroscopy. Generalized estimating equation models were used to compare the sensitivity and specificity of the routine MR imaging protocol with and without T2 maps in the detection of surgically confirmed cartilage lesions. The sensitivity and specificity in the detection of 351 cartilage lesions were 74.6% and 97.8%, respectively, for the routine MR protocol alone and 88.9% and 93.1% for the routine MR protocol with T2 maps. Differences in sensitivity and specificity were statistically significant (P < .001). The addition of T2 maps to the routine MR imaging protocol significantly improved the sensitivity in the detection of 24 areas of cartilage softening (from 4.2% to 62%, P < .001), 41 areas of cartilage fibrillation (from 20% to 66%, P < .001), and 96 superficial partial-thickness cartilage defects (from 71% to 88%, P = .004). The addition of a T2 mapping sequence to a routine MR protocol at 3.0 T improved sensitivity in the detection of cartilage lesions within the knee

  2. Gamification of Clinical Routine: The Dr. Fill Approach.

    PubMed

    Bukowski, Mark; Kühn, Martin; Zhao, Xiaoqing; Bettermann, Ralf; Jonas, Stephan

    2016-01-01

    Gamification is used in clinical context in the health care education. Furthermore, it has shown great promises to improve the performance of the health care staff in their daily routine. In this work we focus on the medication sorting task, which is performed manually in hospitals. This task is very error prone and needs to be performed daily. Nevertheless, errors in the medication are crucial and lead to serious complications. In this work we present a real world gamification approach of the medication sorting task in a patient's daily pill organizer. The player of the game needs to sort the correct medication into the correct dispenser slots and is rewarded or punished in real time. At the end of the game, a score is given and the user can register in a leaderboard.

  3. Delivering value in dermatology: insights from skin cancer detection in routine clinical visits.

    PubMed

    Enamandram, Monica; Duncan, Lyn M; Kimball, Alexandra B

    2015-02-01

    There are increasing demands to demonstrate and report on outcomes in dermatology. Skin cancer diagnosis through skin examination has been well studied, and is promising as a value-delivering intervention. This study seeks to identify the rate of skin cancer diagnosis during routine visits to a large tertiary dermatology clinic. Medical records of patients presenting for routine dermatologic care at Massachusetts General Hospital between March 28 and September 28, 2012, were retrospectively reviewed. All patients given a diagnosis of nonmelanoma skin cancer (NMSC) confirmed on biopsy specimen were identified. Billing data were used to identify the total number of patients evaluated during the study period. NMSC was diagnosed in 1266 skin biopsy specimens from 1047 (7.0%) of the 14,829 patients who presented for routine care. In all, 55% of patients with NMSC were men (mean age 70 years). Chief symptoms of patients with NMSC included general dermatologic concerns (37%), routine cancer screening (43%), and specific lesion(s) of concern (19%). Retrospective design and restriction to a single institution may limit the generalizability of our findings. The incidence of NMSC in routine dermatology is high; these findings validate the value of care provided by dermatologists and highlight the likely increasing need for their diagnostic skills as the population ages in the United States. Copyright © 2014 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Identifying complications of interventional procedures from UK routine healthcare databases: a systematic search for methods using clinical codes.

    PubMed

    Keltie, Kim; Cole, Helen; Arber, Mick; Patrick, Hannah; Powell, John; Campbell, Bruce; Sims, Andrew

    2014-11-28

    Several authors have developed and applied methods to routine data sets to identify the nature and rate of complications following interventional procedures. But, to date, there has been no systematic search for such methods. The objective of this article was to find, classify and appraise published methods, based on analysis of clinical codes, which used routine healthcare databases in a United Kingdom setting to identify complications resulting from interventional procedures. A literature search strategy was developed to identify published studies that referred, in the title or abstract, to the name or acronym of a known routine healthcare database and to complications from procedures or devices. The following data sources were searched in February and March 2013: Cochrane Methods Register, Conference Proceedings Citation Index - Science, Econlit, EMBASE, Health Management Information Consortium, Health Technology Assessment database, MathSciNet, MEDLINE, MEDLINE in-process, OAIster, OpenGrey, Science Citation Index Expanded and ScienceDirect. Of the eligible papers, those which reported methods using clinical coding were classified and summarised in tabular form using the following headings: routine healthcare database; medical speciality; method for identifying complications; length of follow-up; method of recording comorbidity. The benefits and limitations of each approach were assessed. From 3688 papers identified from the literature search, 44 reported the use of clinical codes to identify complications, from which four distinct methods were identified: 1) searching the index admission for specified clinical codes, 2) searching a sequence of admissions for specified clinical codes, 3) searching for specified clinical codes for complications from procedures and devices within the International Classification of Diseases 10th revision (ICD-10) coding scheme which is the methodology recommended by NHS Classification Service, and 4) conducting manual clinical

  5. Using Anatomic Magnetic Resonance Image Information to Enhance Visualization and Interpretation of Functional Images: A Comparison of Methods Applied to Clinical Arterial Spin Labeling Images

    PubMed Central

    Dai, Weiying; Soman, Salil; Hackney, David B.; Wong, Eric T.; Robson, Philip M.; Alsop, David C.

    2017-01-01

    Functional imaging provides hemodynamic and metabolic information and is increasingly being incorporated into clinical diagnostic and research studies. Typically functional images have reduced signal-to-noise ratio and spatial resolution compared to other non-functional cross sectional images obtained as part of a routine clinical protocol. We hypothesized that enhancing visualization and interpretation of functional images with anatomic information could provide preferable quality and superior diagnostic value. In this work, we implemented five methods (frequency addition, frequency multiplication, wavelet transform, non-subsampled contourlet transform and intensity-hue-saturation) and a newly proposed ShArpening by Local Similarity with Anatomic images (SALSA) method to enhance the visualization of functional images, while preserving the original functional contrast and quantitative signal intensity characteristics over larger spatial scales. Arterial spin labeling blood flow MR images of the brain were visualization enhanced using anatomic images with multiple contrasts. The algorithms were validated on a numerical phantom and their performance on images of brain tumor patients were assessed by quantitative metrics and neuroradiologist subjective ratings. The frequency multiplication method had the lowest residual error for preserving the original functional image contrast at larger spatial scales (55%–98% of the other methods with simulated data and 64%–86% with experimental data). It was also significantly more highly graded by the radiologists (p<0.005 for clear brain anatomy around the tumor). Compared to other methods, the SALSA provided 11%–133% higher similarity with ground truth images in the simulation and showed just slightly lower neuroradiologist grading score. Most of these monochrome methods do not require any prior knowledge about the functional and anatomic image characteristics, except the acquired resolution. Hence, automatic

  6. Mould routine identification in the clinical laboratory by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Cassagne, Carole; Ranque, Stéphane; Normand, Anne-Cécile; Fourquet, Patrick; Thiebault, Sandrine; Planard, Chantal; Hendrickx, Marijke; Piarroux, Renaud

    2011-01-01

    MALDI-TOF MS recently emerged as a valuable identification tool for bacteria and yeasts and revolutionized the daily clinical laboratory routine. But it has not been established for routine mould identification. This study aimed to validate a standardized procedure for MALDI-TOF MS-based mould identification in clinical laboratory. First, pre-extraction and extraction procedures were optimized. With this standardized procedure, a 143 mould strains reference spectra library was built. Then, the mould isolates cultured from sequential clinical samples were prospectively subjected to this MALDI-TOF MS based-identification assay. MALDI-TOF MS-based identification was considered correct if it was concordant with the phenotypic identification; otherwise, the gold standard was DNA sequence comparison-based identification. The optimized procedure comprised a culture on sabouraud-gentamicin-chloramphenicol agar followed by a chemical extraction of the fungal colonies with formic acid and acetonitril. The identification was done using a reference database built with references from at least four culture replicates. For five months, 197 clinical isolates were analyzed; 20 were excluded because they were not identified at the species level. MALDI-TOF MS-based approach correctly identified 87% (154/177) of the isolates analyzed in a routine clinical laboratory activity. It failed in 12% (21/177), whose species were not represented in the reference library. MALDI-TOF MS-based identification was correct in 154 out of the remaining 156 isolates. One Beauveria bassiana was not identified and one Rhizopus oryzae was misidentified as Mucor circinelloides. This work's seminal finding is that a standardized procedure can also be used for MALDI-TOF MS-based identification of a wide array of clinically relevant mould species. It thus makes it possible to identify moulds in the routine clinical laboratory setting and opens new avenues for the development of an integrated MALDI-TOF MS

  7. Comprehensive, powerful, efficient, intuitive: a new software framework for clinical imaging applications

    NASA Astrophysics Data System (ADS)

    Augustine, Kurt E.; Holmes, David R., III; Hanson, Dennis P.; Robb, Richard A.

    2006-03-01

    One of the greatest challenges for a software engineer is to create a complex application that is comprehensive enough to be useful to a diverse set of users, yet focused enough for individual tasks to be carried out efficiently with minimal training. This "powerful yet simple" paradox is particularly prevalent in advanced medical imaging applications. Recent research in the Biomedical Imaging Resource (BIR) at Mayo Clinic has been directed toward development of an imaging application framework that provides powerful image visualization/analysis tools in an intuitive, easy-to-use interface. It is based on two concepts very familiar to physicians - Cases and Workflows. Each case is associated with a unique patient and a specific set of routine clinical tasks, or a workflow. Each workflow is comprised of an ordered set of general-purpose modules which can be re-used for each unique workflow. Clinicians help describe and design the workflows, and then are provided with an intuitive interface to both patient data and analysis tools. Since most of the individual steps are common to many different workflows, the use of general-purpose modules reduces development time and results in applications that are consistent, stable, and robust. While the development of individual modules may reflect years of research by imaging scientists, new customized workflows based on the new modules can be developed extremely fast. If a powerful, comprehensive application is difficult to learn and complicated to use, it will be unacceptable to most clinicians. Clinical image analysis tools must be intuitive and effective or they simply will not be used.

  8. Image Display and Manipulation System (IDAMS) program documentation, Appendixes A-D. [including routines, convolution filtering, image expansion, and fast Fourier transformation

    NASA Technical Reports Server (NTRS)

    Cecil, R. W.; White, R. A.; Szczur, M. R.

    1972-01-01

    The IDAMS Processor is a package of task routines and support software that performs convolution filtering, image expansion, fast Fourier transformation, and other operations on a digital image tape. A unique task control card for that program, together with any necessary parameter cards, selects each processing technique to be applied to the input image. A variable number of tasks can be selected for execution by including the proper task and parameter cards in the input deck. An executive maintains control of the run; it initiates execution of each task in turn and handles any necessary error processing.

  9. Real-Time Patient Survey Data During Routine Clinical Activities for Rapid-Cycle Quality Improvement

    PubMed Central

    Jones, Robert E

    2015-01-01

    Background Surveying patients is increasingly important for evaluating and improving health care delivery, but practical survey strategies during routine care activities have not been available. Objective We examined the feasibility of conducting routine patient surveys in a primary care clinic using commercially available technology (Web-based survey creation, deployment on tablet computers, cloud-based management of survey data) to expedite and enhance several steps in data collection and management for rapid quality improvement cycles. Methods We used a Web-based data management tool (survey creation, deployment on tablet computers, real-time data accumulation and display of survey results) to conduct four patient surveys during routine clinic sessions over a one-month period. Each survey consisted of three questions and focused on a specific patient care domain (dental care, waiting room experience, care access/continuity, Internet connectivity). Results Of the 727 available patients during clinic survey days, 316 patients (43.4%) attempted the survey, and 293 (40.3%) completed the survey. For the four 3-question surveys, the average time per survey was overall 40.4 seconds, with a range of 5.4 to 20.3 seconds for individual questions. Yes/No questions took less time than multiple choice questions (average 9.6 seconds versus 14.0). Average response time showed no clear pattern by order of questions or by proctor strategy, but monotonically increased with number of words in the question (<20 words, 21-30 words, >30 words)—8.0, 11.8, 16.8, seconds, respectively. Conclusions This technology-enabled data management system helped capture patient opinions, accelerate turnaround of survey data, with minimal impact on a busy primary care clinic. This new model of patient survey data management is feasible and sustainable in a busy office setting, supports and engages clinicians in the quality improvement process, and harmonizes with the vision of a learning health

  10. Real-time patient survey data during routine clinical activities for rapid-cycle quality improvement.

    PubMed

    Wofford, James Lucius; Campos, Claudia L; Jones, Robert E; Stevens, Sheila F

    2015-03-12

    Surveying patients is increasingly important for evaluating and improving health care delivery, but practical survey strategies during routine care activities have not been available. We examined the feasibility of conducting routine patient surveys in a primary care clinic using commercially available technology (Web-based survey creation, deployment on tablet computers, cloud-based management of survey data) to expedite and enhance several steps in data collection and management for rapid quality improvement cycles. We used a Web-based data management tool (survey creation, deployment on tablet computers, real-time data accumulation and display of survey results) to conduct four patient surveys during routine clinic sessions over a one-month period. Each survey consisted of three questions and focused on a specific patient care domain (dental care, waiting room experience, care access/continuity, Internet connectivity). Of the 727 available patients during clinic survey days, 316 patients (43.4%) attempted the survey, and 293 (40.3%) completed the survey. For the four 3-question surveys, the average time per survey was overall 40.4 seconds, with a range of 5.4 to 20.3 seconds for individual questions. Yes/No questions took less time than multiple choice questions (average 9.6 seconds versus 14.0). Average response time showed no clear pattern by order of questions or by proctor strategy, but monotonically increased with number of words in the question (<20 words, 21-30 words, >30 words)-8.0, 11.8, 16.8, seconds, respectively. This technology-enabled data management system helped capture patient opinions, accelerate turnaround of survey data, with minimal impact on a busy primary care clinic. This new model of patient survey data management is feasible and sustainable in a busy office setting, supports and engages clinicians in the quality improvement process, and harmonizes with the vision of a learning health care system.

  11. Allergy to kiwi: is component-resolved diagnosis in routine clinical practice really impossible?

    PubMed

    Asero, R

    2012-04-01

    Kiwi allergy is frequent and can be the result of sensitization to a number of allergens showing different physicochemical characteristics. Component-resolved diagnosis of kiwi allergy is still unavailable in routine clinical practice. To investigate whether component resolved-diagnosis of kiwi allergy can be, at least in part, carried out by a proper combination of routinely available diagnostic tools. 63 adults with plant food allergy were studied 36 were kiwi-allergic while 27 were kiwi-tolerant and served as controls. Patients and controls underwent SPT with commercial peach and kiwi extracts, and with aprofilin-enriched date palm pollen extract (all by ALK-Abellò), and the measurement of IgE to birch, kiwi, and natural rubber latex. The in-vitro test showed poor sensitivity and specificity, as it scored positive in about 50% of patients and controls irrespective of clinical allergy to kiwi. The kiwi SPT showed overall poor sensitivity; however, it scored negative in all subjects with pollen food-allergy syndrome, was weakly positive in some lipid transfer protein-hypersensitive/kiwi tolerant subjects and in one latex-sensitized subject, and strongly positive in all subjects with primary kiwi sensitization. SPT with this commercial kiwi extract sensitively and specifically detects patients reacting to specific kiwi allergens. This can be useful to detect patients that are at risk of potentially severe reactions, particularly in case of co-sensitization to labile allergens, while we wait that the whole spectrum of kiwi allergens becomes available for routine in-vitro testing.

  12. Reliability of shear wave ultrasound elastography for neck lesions identified in routine clinical practice.

    PubMed

    Bhatia, K; Tong, C S L; Cho, C C M; Yuen, E H Y; Lee, J; Ahuja, A T

    2012-10-01

    To evaluate the reliability of shear wave ultrasound elastography (SWE) in the neck. 176 neck lesions (40 thyroid, 56 lymph nodes, 46 salivary, 34 miscellaneous) identified in a routine US clinic underwent SWE by one or two blinded radiologists. For this study, SWE required the operator to acquire three 10 second dynamic colour-coded SWE cineloops per lesion, select one static image per cineloop, and place circular regions-of-interest within the entire lesion and stiffest part to generate 3 SWE measurements per static image. For logistical reasons, one radiologist evaluated all 176 lesions and the other evaluated 58 lesions. Both radiologists also reviewed 27 archived cineloops independently to assess SWE excluding practical technique. Reliability was assessed using intraclass correlation coefficients (ICCs) concordance correlation coefficients (CCCs) and coefficients of repeatability (CORs). Test-retest ICCs for the radiologist evaluating 176 lesions were 0.78 - 0.85 (fair-excellent agreement), CCCs were 0.85 - 0.88 (substantial agreement), and CORs were 14.9 - 36.1 kPa. For both radiologists evaluating 58 lesions, intra-rater and inter-rater ICCs were 0.65 - 0.78 and 0.72 - 0.77 respectively. For SWE excluding practical technique, inter-rater ICCs were 0.97 - 0.98 (excellent agreement). ICCs differed according to tissue, being higher in thyroid lesions than lymph nodes (p < 0.001), and higher in benign than malignant lesions (p values < 0.001). Intra- and inter-rater reliability of SWE is fair to excellent according to ICCs. SWE reliability is influenced appreciably by acquisition technique. Nevertheless, CORs for SWE are not negligible. To determine whether these results are acceptable clinically, further research is required to establish SWE stiffness values of normal and pathological tissues in the neck. © Georg Thieme Verlag KG Stuttgart · New York.

  13. [Management of aflibercept in routine clinical practice].

    PubMed

    Cabrera López, F

    2015-03-01

    Aflibercept is a new anti-vegf drug that, unlike ranibizumab and bevacizumab blocks both vegf-A and placental growth factor. Moreover, it binds with much greater strength and affinity to human VEGF-A165 than other endogenous vegf receptors, conferring it with a more extended effect and allowing a lower frequency of intravitreal injections. This facilitates the adoption of fixed treatment regimens other than monthly or individual regimens such as "treat and extend". Aflibercept is indicated for the treatment of neovascular (exudative) age-related macular degeneration (ARMD), visual alteration due to macular edema secondary to central retinal vein occlusion (CRVO) and visual alteration due to diabetic macular edema (DME). The present article reviews the management of aflibercept in routine clinical practice, based on the specifications of its new core data sheet, which includes all the therapeutic indications in which its use has been approved and evaluating the distinct alternatives and treatment regimens after the initial loading doses. Copyright © 2015 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  14. Imaging Techniques for Clinical Burn Assessment with a Focus on Multispectral Imaging

    PubMed Central

    Thatcher, Jeffrey E.; Squiers, John J.; Kanick, Stephen C.; King, Darlene R.; Lu, Yang; Wang, Yulin; Mohan, Rachit; Sellke, Eric W.; DiMaio, J. Michael

    2016-01-01

    Significance: Burn assessments, including extent and severity, are some of the most critical diagnoses in burn care, and many recently developed imaging techniques may have the potential to improve the accuracy of these evaluations. Recent Advances: Optical devices, telemedicine, and high-frequency ultrasound are among the highlights in recent burn imaging advancements. We present another promising technology, multispectral imaging (MSI), which also has the potential to impact current medical practice in burn care, among a variety of other specialties. Critical Issues: At this time, it is still a matter of debate as to why there is no consensus on the use of technology to assist burn assessments in the United States. Fortunately, the availability of techniques does not appear to be a limitation. However, the selection of appropriate imaging technology to augment the provision of burn care can be difficult for clinicians to navigate. There are many technologies available, but a comprehensive review summarizing the tissue characteristics measured by each technology in light of aiding clinicians in selecting the proper device is missing. This would be especially valuable for the nonburn specialists who encounter burn injuries. Future Directions: The questions of when burn assessment devices are useful to the burn team, how the various imaging devices work, and where the various burn imaging technologies fit into the spectrum of burn care will continue to be addressed. Technologies that can image a large surface area quickly, such as thermography or laser speckle imaging, may be suitable for initial burn assessment and triage. In the setting of presurgical planning, ultrasound or optical microscopy techniques, including optical coherence tomography, may prove useful. MSI, which actually has origins in burn care, may ultimately meet a high number of requirements for burn assessment in routine clinical use. PMID:27602255

  15. ACR Appropriateness Criteria® Routine Chest Radiography.

    PubMed

    McComb, Barbara L; Chung, Jonathan H; Crabtree, Traves D; Heitkamp, Darel E; Iannettoni, Mark D; Jokerst, Clinton; Saleh, Anthony G; Shah, Rakesh D; Steiner, Robert M; Mohammed, Tan-Lucien H; Ravenel, James G

    2016-03-01

    Chest radiographs are sometimes taken before surgeries and interventional procedures on hospital admissions and outpatients. This manuscript summarizes the American College of Radiology review of the literature and recommendations on routinely performed chest radiographies in these settings. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every 3 years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer-reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances in which evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.

  16. Biomedical data mining in clinical routine: expanding the impact of hospital information systems.

    PubMed

    Müller, Marcel; Markó, Kornel; Daumke, Philipp; Paetzold, Jan; Roesner, Arnold; Klar, Rüdiger

    2007-01-01

    In this paper we want to describe how the promising technology of biomedical data mining can improve the use of hospital information systems: a large set of unstructured, narrative clinical data from a dermatological university hospital like discharge letters or other dermatological reports were processed through a morpho-semantic text retrieval engine ("MorphoSaurus") and integrated with other clinical data using a web-based interface and brought into daily clinical routine. The user evaluation showed a very high user acceptance - this system seems to meet the clinicians' requirements for a vertical data mining in the electronic patient records. What emerges is the need for integration of biomedical data mining into hospital information systems for clinical, scientific, educational and economic reasons.

  17. Advanced-stage Hodgkin lymphoma: US/chest radiography for detection of relapse in patients in first complete remission--a randomized trial of routine surveillance imaging procedures.

    PubMed

    Picardi, Marco; Pugliese, Novella; Cirillo, Michele; Zeppa, Pio; Cozzolino, Imma; Ciancia, Giuseppe; Pettinato, Guido; Salvatore, Claudia; Quintarelli, Concetta; Pane, Fabrizio

    2014-07-01

    To compare the use of fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) with the use of a combination of ultrasonography (US) and chest radiography for systematic follow-up of patients with high-risk Hodgkin lymphoma. Institutional review board approval and informed consent were obtained. In a single center between January 2001 and December 2009, patients with advanced-stage Hodgkin lymphoma who had responded completely to first-line treatment were randomly assigned (1:1) to follow-up with either PET/CT or US/chest radiography. Follow-up included clinical and imaging procedures at 4, 8, 12, 16, 20, 24, 30, 36, 48, 60, 84, and 108 months after treatment discontinuation. When clinical and/or imaging results were positive, recurrence was confirmed histologically. The primary endpoint was to compare the sensitivity of the two follow-up imaging approaches. Secondary endpoints were their specificity, positive and negative predictive values, time to recurrence detection, radiation risks, and costs. A total of 300 patients were randomized into the two arms. The study was closed after a median follow-up time of 60 months, with a relapse rate of 27%. Sensitivity for detection of Hodgkin lymphoma was similar for the two follow-up approaches. All of the relapses (40 of 40) were identified with FDG PET/CT (100%) and 39 of 40 relapses were identified with US/chest radiography (97.5%; P = .0001 for the equivalence test). US/chest radiography showed significantly higher specificity and positive predictive value than did PET/CT (96% [106 of 110] vs 86% [95 of 110], respectively; P = .02; and 91% [39 of 43] vs 73% [40 of 55], respectively; P = .01). Exposure to ionizing radiation was estimated to be 14.5 mSv for one PET/CT examination versus 0.1 mSv for one chest radiographic examination. Estimated cost per relapse diagnosed with routine PET/CT was 10-fold higher compared with that diagnosed with routine US/chest radiography. US and

  18. Barium swallow study in routine clinical practice: a prospective study in patients with chronic cough*,**

    PubMed Central

    Nin, Carlos Shuler; Marchiori, Edson; Irion, Klaus Loureiro; Paludo, Artur de Oliveira; Alves, Giordano Rafael Tronco; Hochhegger, Daniela Reis; Hochhegger, Bruno

    2013-01-01

    OBJECTIVE: To assess the routine use of barium swallow study in patients with chronic cough. METHODS: Between October of 2011 and March of 2012, 95 consecutive patients submitted to chest X-ray due to chronic cough (duration > 8 weeks) were included in the study. For study purposes, additional images were obtained immediately after the oral administration of 5 mL of a 5% barium sulfate suspension. Two radiologists systematically evaluated all of the images in order to identify any pathological changes. Fisher's exact test and the chi-square test for categorical data were used in the comparisons. RESULTS: The images taken immediately after barium swallow revealed significant pathological conditions that were potentially related to chronic cough in 12 (12.6%) of the 95 patients. These conditions, which included diaphragmatic hiatal hernia, esophageal neoplasm, achalasia, esophageal diverticulum, and abnormal esophageal dilatation, were not detected on the images taken without contrast. After appropriate treatment, the symptoms disappeared in 11 (91.6%) of the patients, whereas the treatment was ineffective in 1 (8.4%). We observed no complications related to barium swallow, such as contrast aspiration. CONCLUSIONS: Barium swallow improved the detection of significant radiographic findings related to chronic cough in 11.5% of patients. These initial findings suggest that the routine use of barium swallow can significantly increase the sensitivity of chest X-rays in the detection of chronic cough-related etiologies. PMID:24473762

  19. Intraoperative imaging during Mohs surgery with reflectance confocal microscopy: initial clinical experience

    NASA Astrophysics Data System (ADS)

    Flores, Eileen S.; Cordova, Miguel; Kose, Kivanc; Phillips, William; Rossi, Anthony; Nehal, Kishwer; Rajadhyaksha, Milind

    2015-06-01

    Mohs surgery for the removal of nonmelanoma skin cancers (NMSCs) is performed in stages, while being guided by the examination for residual tumor with frozen pathology. However, preparation of frozen pathology at each stage is time consuming and labor intensive. Real-time intraoperative reflectance confocal microscopy (RCM), combined with video mosaicking, may enable rapid detection of residual tumor directly in the surgical wounds on patients. We report our initial experience on 25 patients, using aluminum chloride for nuclear contrast. Imaging was performed in quadrants in the wound to simulate the Mohs surgeon's examination of pathology. Images and videos of the epidermal and dermal margins were found to be of clinically acceptable quality. Bright nuclear morphology was identified at the epidermal margin and detectable in residual NMSC tumors. The presence of residual tumor and normal skin features could be detected in the peripheral and deep dermal margins. Intraoperative RCM imaging may enable detection of residual tumor directly on patients during Mohs surgery, and may serve as an adjunct for frozen pathology. Ultimately, for routine clinical utility, a stronger tumor-to-dermis contrast may be necessary, and also a smaller microscope with an automated approach for imaging in the entire wound in a rapid and controlled manner.

  20. Value analysis of postoperative staging imaging for asymptomatic, early-stage breast cancer: implications of clinical variation on utility and cost.

    PubMed

    Pellet, Andrew C; Erten, Mujde Z; James, Ted A

    2016-06-01

    Routine staging imaging for early-stage breast cancer is not recommended. Despite this, there is clinical practice variation with imaging studies obtained for asymptomatic patients with a positive sentinel node (SN+). We characterize the utility, cost, and clinical implications of imaging studies obtained in asymptomatic SN+ patients. A retrospective review was performed of asymptomatic, clinically node-negative patients who were found to have a positive sentinel node after surgery. The type of imaging, subsequent tests/interventions, frequency of additional malignancy detected, and costs were recorded. From April 2009 to April 2013, a total of 50 of 113 (44%) asymptomatic patients underwent staging imaging for a positive sentinel node; 11 (22%) patients had at least 1 subsequent imaging study or diagnostic intervention. No instance of metastatic breast cancer was identified, with a total cost of imaging calculated at $116,905. Staging imaging for asymptomatic SN+ breast cancer demonstrates clinical variation. These tests were associated with low utility, increased costs, and frequent false positives leading to subsequent testing/intervention. Evidence-based standardization may help increase quality by decreasing unnecessary variation and cost. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Routine versus selective contrast imaging to identify the need for early re-intervention following laparoscopic fundoplication: A retrospective cohort study.

    PubMed

    Shahzad, Khalid; Menon, Ashok; Turner, Paul; Ward, Jeremy; Pursnani, Kishore; Alkhaffaf, Bilal

    2015-08-01

    The prompt recognition of complications is essential in reducing morbidity following anti-reflux surgery. Consequently, many centres employ a policy of routine post-operative contrast studies. The study aimed to examine whether routine contrast studies more effectively recognised early post-operative complications following anti-reflux surgery compared with selective use. This was a retrospective analysis of 240 adults who had undergone primary anti-reflux surgery. Selective use of water-soluble contrast swallows was employed for 115 patients (Group 1) while 125 patients (Group 2) had routine studies. 10 (0.9%) patients from Group 1 underwent contrast studies, four (40%) of which were abnormal. Routine studies in Group 2 identified thirty-two abnormalities (27%) however the inter-group difference was not significant (p = 0.32). Only one case from group 2 required immediate re-intervention. This was not statistically significant (p = 0.78). Multivariate analysis found no significant association between selective or routine imaging and re-intervention rates. One patient from group 2 presented three days following discharge with wrap migration requiring reoperation despite a normal post-operative study. Routine use of contrast imaging following anti-reflux and hiatus hernia surgery is not necessary. It does not identify a significantly greater number of post-operative complications in comparison to selective use. Additionally, routine use of contrast studies does not ensure the diagnosis of all complications in the post-operative period. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  2. Technical solutions for simultaneous MEG and SEEG recordings: towards routine clinical use.

    PubMed

    Badier, J M; Dubarry, A S; Gavaret, M; Chen, S; Trébuchon, A S; Marquis, P; Régis, J; Bartolomei, F; Bénar, C G; Carron, R

    2017-09-21

    The simultaneous recording of intracerebral EEG (stereotaxic EEG, SEEG) and magnetoencephalography (MEG) is a promising strategy that provides both local and global views on brain pathological activity. Yet, acquiring simultaneous signals poses difficult technical issues that hamper their use in clinical routine. Our objective was thus to develop a set of solutions for recording a high number of SEEG channels while preserving signal quality. We recorded data in a patient with drug resistant epilepsy during presurgical evaluation. We used dedicated insertion screws and optically insulated amplifiers. We recorded 137 SEEG contacts on 10 depth electrodes (5-15 contacts each) and 248 MEG channels (magnetometers). Signal quality was assessed by comparing the distribution of RMS values in different frequency bands to a reference set of MEG acquisitions. The quality of signals was excellent for both MEG and SEEG; for MEG, it was comparable to that of MEG signals without concurrent SEEG. Discharges involving several structures on SEEG were visible on MEG, whereas discharges limited in space were not seen at the surface. SEEG can now be recorded simultaneously with whole-head MEG in routine. This opens new avenues, both methodologically for understanding signals and improving signal processing methods, and clinically for future combined analyses.

  3. Clinical imaging of the pancreas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    May, G.; Gardiner, R.

    1987-01-01

    Featuring more than 300 high-quality radiographs and scan images, clinical imaging of the pancreas systematically reviews all appropriate imaging modalities for diagnosing and evaluating a variety of commonly encountered pancreatic disorders. After presenting a succinct overview of pancreatic embryology, anatomy, and physiology, the authors establish the clinical indications-including postoperative patient evaluation-for radiologic examination of the pancreas. The diagnostic capabilities and limitations of currently available imaging techniques for the pancreas are thoroughly assessed, with carefully selected illustrations depicting the types of images and data obtained using these different techniques. The review of acute and chronic pancreatitis considers the clinical features andmore » possible complications of their variant forms and offers guidance in selecting appropriate imaging studies.« less

  4. A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality

    PubMed Central

    Favazza, Christopher P.; Duan, Xinhui; Zhang, Yi; Yu, Lifeng; Leng, Shuai; Kofler, James M.; Bruesewitz, Michael R.; McCollough, Cynthia H.

    2015-01-01

    Through this investigation we developed a methodology to evaluate and standardize CT image quality from routine abdomen protocols across different manufacturers and models. The influence of manufacturer-specific automated exposure control systems on image quality was directly assessed to standardize performance across a range of patient sizes. We evaluated 16 CT scanners across our health system, including Siemens, GE, and Toshiba models. Using each practice’s routine abdomen protocol, we measured spatial resolution, image noise, and scanner radiation output (CTDIvol). Axial and in-plane spatial resolutions were assessed through slice sensitivity profile (SSP) and modulation transfer function (MTF) measurements, respectively. Image noise and CTDIvol values were obtained for three different phantom sizes. SSP measurements demonstrated a bimodal distribution in slice widths: an average of 6.2 ± 0.2 mm using GE’s “Plus” mode reconstruction setting and 5.0 ± 0.1 mm for all other scanners. MTF curves were similar for all scanners. Average spatial frequencies at 50%, 10%, and 2% MTF values were 3.24 ± 0.37, 6.20 ± 0.34, and 7.84 ± 0.70 lp/cm, respectively. For all phantom sizes, image noise and CTDIvol varied considerably: 6.5–13.3 HU (noise) and 4.8–13.3 mGy (CTDIvol) for the smallest phantom; 9.1–18.4 HU and 9.3–28.8 mGy for the medium phantom; and 7.8–23.4 HU and 16.0–48.1 mGy for the largest phantom. Using these measurements and benchmark SSP, MTF, and image noise targets, CT image quality can be standardized across a range of patient sizes. PMID:26459751

  5. Leveraging Clinical Imaging Archives for Radiomics: Reliability of Automated Methods for Brain Volume Measurement.

    PubMed

    Adduru, Viraj R; Michael, Andrew M; Helguera, Maria; Baum, Stefi A; Moore, Gregory J

    2017-09-01

    Purpose To validate the use of thick-section clinically acquired magnetic resonance (MR) imaging data for estimating total brain volume (TBV), gray matter (GM) volume (GMV), and white matter (WM) volume (WMV) by using three widely used automated toolboxes: SPM ( www.fil.ion.ucl.ac.uk/spm/ ), FreeSurfer ( surfer.nmr.mgh.harvard.edu ), and FSL (FMRIB software library; Oxford Centre for Functional MR Imaging of the Brain, Oxford, England, https://fsl.fmrib.ox.ac.uk/fsl ). Materials and Methods MR images from a clinical archive were used and data were deidentified. The three methods were applied to estimate brain volumes from thin-section research-quality brain MR images and routine thick-section clinical MR images acquired from the same 38 patients (age range, 1-71 years; mean age, 22 years; 11 women). By using these automated methods, TBV, GMV, and WMV were estimated. Thin- versus thick-section volume comparisons were made for each method by using intraclass correlation coefficients (ICCs). Results SPM exhibited excellent ICCs (0.97, 0.85, and 0.83 for TBV, GMV, and WMV, respectively). FSL exhibited ICCs of 0.69, 0.51, and 0.60 for TBV, GMV, and WMV, respectively, but they were lower than with SPM. FreeSurfer exhibited excellent ICC of 0.63 only for TBV. Application of SPM's voxel-based morphometry on the modulated images of thin-section images and interpolated thick-section images showed fair to excellent ICCs (0.37-0.98) for the majority of brain regions (88.47% [306924 of 346916 voxels] of WM and 80.35% [377 282 of 469 502 voxels] of GM). Conclusion Thick-section clinical-quality MR images can be reliably used for computing quantitative brain metrics such as TBV, GMV, and WMV by using SPM. © RSNA, 2017 Online supplemental material is available for this article.

  6. Clinical evaluation of watermarked medical images.

    PubMed

    Zain, Jasni M; Fauzi, Abdul M; Aziz, Azian A

    2006-01-01

    Digital watermarking medical images provides security to the images. The purpose of this study was to see whether digitally watermarked images changed clinical diagnoses when assessed by radiologists. We embedded 256 bits watermark to various medical images in the region of non-interest (RONI) and 480K bits in both region of interest (ROI) and RONI. Our results showed that watermarking medical images did not alter clinical diagnoses. In addition, there was no difference in image quality when visually assessed by the medical radiologists. We therefore concluded that digital watermarking medical images were safe in terms of preserving image quality for clinical purposes.

  7. Individualized radiotherapy by combining high-end irradiation and magnetic resonance imaging.

    PubMed

    Combs, Stephanie E; Nüsslin, Fridtjof; Wilkens, Jan J

    2016-04-01

    Image-guided radiotherapy (IGRT) has been integrated into daily clinical routine and can today be considered the standard especially with high-dose radiotherapy. Currently imaging is based on MV- or kV-CT, which has clear limitations especially in soft-tissue contrast. Thus, combination of magnetic resonance (MR) imaging and high-end radiotherapy opens a new horizon. The intricate technical properties of MR imagers pose a challenge to technology when combined with radiation technology. Several solutions that are almost ready for routine clinical application have been developed. The clinical questions include dose-escalation strategies, monitoring of changes during treatment as well as imaging without additional radiation exposure during treatment.

  8. Reliability of Classifying Multiple Sclerosis Disease Activity Using Magnetic Resonance Imaging in a Multiple Sclerosis Clinic

    PubMed Central

    Altay, Ebru Erbayat; Fisher, Elizabeth; Jones, Stephen E.; Hara-Cleaver, Claire; Lee, Jar-Chi; Rudick, Richard A.

    2013-01-01

    Objective To assess the reliability of new magnetic resonance imaging (MRI) lesion counts by clinicians in a multiple sclerosis specialty clinic. Design An observational study. Setting A multiple sclerosis specialty clinic. Patients Eighty-five patients with multiple sclerosis participating in a National Institutes of Health–supported longitudinal study were included. Intervention Each patient had a brain MRI scan at entry and 6 months later using a standardized protocol. Main Outcome Measures The number of new T2 lesions, newly enlarging T2 lesions, and gadolinium-enhancing lesions were measured on the 6-month MRI using a computer-based image analysis program for the original study. For this study, images were reanalyzed by an expert neuroradiologist and 3 clinician raters. The neuroradiologist evaluated the original image pairs; the clinicians evaluated image pairs that were modified to simulate clinical practice. New lesion counts were compared across raters, as was classification of patients as MRI active or inactive. Results Agreement on lesion counts was highest for gadolinium-enhancing lesions, intermediate for new T2 lesions, and poor for enlarging T2 lesions. In 18% to 25% of the cases, MRI activity was classified differently by the clinician raters compared with the neuroradiologist or computer program. Variability among the clinical raters for estimates of new T2 lesions was affected most strongly by the image modifications that simulated low image quality and different head position. Conclusions Between-rater variability in new T2 lesion counts may be reduced by improved standardization of image acquisitions, but this approach may not be practical in most clinical environments. Ultimately, more reliable, robust, and accessible image analysis methods are needed for accurate multiple sclerosis disease-modifying drug monitoring and decision making in the routine clinic setting. PMID:23599930

  9. COPD management: role of symptom assessment in routine clinical practice

    PubMed Central

    van der Molen, Thys; Miravitlles, Marc; Kocks, Janwillem WH

    2013-01-01

    Patients with chronic obstructive pulmonary disease (COPD) present with a variety of symptoms that significantly impair health-related quality of life. Despite this, COPD treatment and its management are mainly based on lung function assessments. There is increasing evidence that conventional lung function measures alone do not correlate well with COPD symptoms and their associated impact on patients’ everyday lives. Instead, symptoms should be assessed routinely, preferably by using patient-centered questionnaires that provide a more accurate guide to the actual burden of COPD. Numerous questionnaires have been developed in an attempt to find a simple and reliable tool to use in everyday clinical practice. In this paper, we review three such patient-reported questionnaires recommended by the latest Global Initiative for Chronic Obstructive Lung Disease guidelines, ie, the modified Medical Research Council questionnaire, the clinical COPD questionnaire, and the COPD Assessment Test, as well as other symptom-specific questionnaires that are currently being developed. PMID:24143085

  10. Osteochondral transplantation of the talus: long-term clinical and magnetic resonance imaging evaluation.

    PubMed

    Imhoff, Andreas B; Paul, Jochen; Ottinger, Benjamin; Wörtler, Klaus; Lämmle, Lena; Spang, Jeffrey; Hinterwimmer, Stefan

    2011-07-01

    Osteochondral lesions of the ankle are a common injury after ankle sprains, especially in young and active patients. The Osteochondral Autograft Transfer System (OATS) is the only 1-step surgical technique designed to replace the entire osteochondral unit. This study was conducted to evaluate the long-term clinical and radiographic outcomes of the OATS procedure for the talus and compare the results of patients who have had prior surgical interventions with patients for whom OATS represents the primary surgical treatment. Case series; Level of evidence, 4. The authors retrospectively analyzed 26 talus OATS procedures (25 patients) with an average follow-up of 84 months (range, 53-124 months); 9 patients had OATS as a second surgical intervention. The patients completed the American Orthopaedic Foot & Ankle Society (AOFAS) and Tegner scores plus the visual analog scale (VAS) preoperatively and at follow-up. Magnetic resonance imaging examinations were conducted on a 1.5-T whole-body magnet that assessed transplant congruency, adjacent surface of the talus, the corresponding distal tibia, and joint effusion. The authors found significant increases for the AOFAS score (50 to 78 points, P < .01) and the Tegner score (3.1 to 3.7, P < .05) and a significant decrease for the VAS (7.8 to 1.5, P < .01) from preoperative to postoperative. Patients with normal integration or minor incongruity of the transplant on magnetic resonance imaging (81%) had significantly better AOFAS scores (P = .03). Other magnetic resonance imaging criteria did not predict clinical results. Patients for whom OATS represented a second procedure had significantly worse clinical AOFAS and Tegner scores plus a higher VAS. Long-term clinical and magnetic resonance imaging results after osteochondral transplantation are good and patients significantly benefit from this surgery. Magnetic resonance imaging should not be a routine control but appears to be indicated when clinical symptoms persist after

  11. WE-G-204-09: Medical Physics 2.0 in Practice: Automated QC Assessment of Clinical Chest Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willis, C; Willis, C; Nishino, T

    2015-06-15

    Purpose: To determine whether a proposed suite of objective image quality metrics for digital chest radiographs is useful for monitoring image quality in our clinical operation. Methods: Seventeen gridless AP Chest radiographs from a GE Optima portable digital radiography (DR) unit (Group 1), seventeen (routine) PA Chest radiographs from a GE Discovery DR unit (Group 2), and sixteen gridless (non-routine) PA Chest radiographs from the same Discovery DR unit (Group 3) were chosen for analysis. Groups were selected to represent “sub-standard” (Group 1), “standard-of-care” (Group 2), and images with a gross technical error (Group 3). Group 1 images were acquiredmore » with lower kVp (90 vs. 125), shorter source-to-image distance (127cm vs 183cm) and were expected to have lower quality than images in Group 2. Group 3 was expected to have degraded contrast versus Group 2.This evaluation was approved by the institutional Quality Improvement Assurance Board (QIAB). Images were anonymized and securely transferred to the Duke University Clinical Imaging Physics Group for analysis using software previously described{sup 1} and validated{sup 2}. Image quality for individual images was reported in terms of lung grey level(Lgl); lung noise(Ln); rib-lung contrast(RLc); rib sharpness(Rs); mediastinum detail(Md), noise(Mn), and alignment(Ma); subdiaphragm-lung contrast(SLc); and subdiaphragm area(Sa). Metrics were compared across groups. Results: Metrics agreed with published Quality Consistency Ranges with three exceptions: higher Lgl, lower RLc, and SDc. Higher bit depth (16 vs 12) accounted for higher Lgl values in our images. Values were most internally consistent for Group 2. The most sensitive metric for distinguishing between groups was Mn followed closely by Ln. The least sensitive metrics were Md and RLc. Conclusion: The software appears promising for objectively and automatically identifying substandard images in our operation. The results can be used to

  12. Attempts to control clothes-borne infection in a burn unit, 2. Clothing routines in clinical use and the epidemiology of cross-colonization.

    PubMed Central

    Ransjö, U.

    1979-01-01

    Previous investigations have shown that cross-contamination in a burn unit is mainly clothes-borne. New barrier garments have been designed and tried experimentally. The aim of the present study was to investigate the effects of different clothing routines on cross-contamination. In a long-term study, the rates and routes of colonizations with Staphylococcus aureus, Streptococcus groups A, B, C, F, and G and Pseudomonas aeruginosa were examined. The exogenous colonization rates were, with S. aureus 77%, with Streptococcus species 52% and with Ps. aeruginosa 32%. The colonization rate with Ps. aeruginosa was higher in patients with larger burns. Patients dispersed Streptococcus and Ps. aeruginosa as well as S. aureus into the air of their rooms in considerable amounts, but dispersers were not more important as sources of cross-colonization than non-dispersers. In comparison of clothing routines, there was no difference in overall colonization rates. The newly designed barrier garment that was made from apparently particle-tight material did not reduce the transfer of bacteria from patient to patient. A less rigid routine than that previously used did not increase the risk of cross-contamination. A thorough change of barrier dress after close contact nursing delayed the first exogenous S. aureus colonization from day 6 to day 14 after admission. This routine might be recommended for clinical use. Otherwise, methods must be developed for adequate selection of materials intended for barrier garments. Images Plate 1 PMID:109498

  13. An alternative clinical routine for subjective refraction based on power vectors with trial frames.

    PubMed

    María Revert, Antonia; Conversa, Maria Amparo; Albarrán Diego, César; Micó, Vicente

    2017-01-01

    Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented at 0°/90° (J 0 component) and 45°/135° (J 45 component) for determination of astigmatism. This vector subjective refraction result (VR) is compared separately for right and left eyes of 25 subjects (mean age, 35 ± 4 years) against conventional sphero-cylindrical subjective refraction (RX) using a phoropter. The VR procedure was applied with both conventional tumbling E optotypes (VR1) and modified optotypes with oblique orientation (VR2). Bland-Altman plots and intra-class correlation coefficient showed good agreement between VR, and RX (with coefficient values above 0.82) and anova showed no significant differences in any of the power vector components between RX and VR. VR1 and VR2 procedure results were similar (p ≥ 0.77). The proposed routine determines the three components of refractive error in power vector notation [M, J 0 , J 45 ], with a refraction time similar to the one used in conventional subjective procedures. The proposed routine could be helpful for inexperienced clinicians and for experienced clinicians in those cases where it is difficult to get a valid starting point for conventional RX (irregular corneas, media opacities, etc.) and for refractive situations/places with inadequate refractive facilities/equipment. © 2016 The Authors Ophthalmic & Physiological

  14. A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality.

    PubMed

    Favazza, Christopher P; Duan, Xinhui; Zhang, Yi; Yu, Lifeng; Leng, Shuai; Kofler, James M; Bruesewitz, Michael R; McCollough, Cynthia H

    2015-11-07

    Through this investigation we developed a methodology to evaluate and standardize CT image quality from routine abdomen protocols across different manufacturers and models. The influence of manufacturer-specific automated exposure control systems on image quality was directly assessed to standardize performance across a range of patient sizes. We evaluated 16 CT scanners across our health system, including Siemens, GE, and Toshiba models. Using each practice's routine abdomen protocol, we measured spatial resolution, image noise, and scanner radiation output (CTDIvol). Axial and in-plane spatial resolutions were assessed through slice sensitivity profile (SSP) and modulation transfer function (MTF) measurements, respectively. Image noise and CTDIvol values were obtained for three different phantom sizes. SSP measurements demonstrated a bimodal distribution in slice widths: an average of 6.2  ±  0.2 mm using GE's 'Plus' mode reconstruction setting and 5.0  ±  0.1 mm for all other scanners. MTF curves were similar for all scanners. Average spatial frequencies at 50%, 10%, and 2% MTF values were 3.24  ±  0.37, 6.20  ±  0.34, and 7.84  ±  0.70 lp cm(-1), respectively. For all phantom sizes, image noise and CTDIvol varied considerably: 6.5-13.3 HU (noise) and 4.8-13.3 mGy (CTDIvol) for the smallest phantom; 9.1-18.4 HU and 9.3-28.8 mGy for the medium phantom; and 7.8-23.4 HU and 16.0-48.1 mGy for the largest phantom. Using these measurements and benchmark SSP, MTF, and image noise targets, CT image quality can be standardized across a range of patient sizes.

  15. Impact of imaging measurements on response assessment in glioblastoma clinical trials

    PubMed Central

    Reardon, David A.; Ballman, Karla V.; Buckner, Jan C.; Chang, Susan M.; Ellingson, Benjamin M.

    2014-01-01

    We provide historical and scientific guidance on imaging response assessment for incorporation into clinical trials to stimulate effective and expedited drug development for recurrent glioblastoma by addressing 3 fundamental questions: (i) What is the current validation status of imaging response assessment, and when are we confident assessing response using today's technology? (ii) What imaging technology and/or response assessment paradigms can be validated and implemented soon, and how will these technologies provide benefit? (iii) Which imaging technologies need extensive testing, and how can they be prospectively validated? Assessment of T1 +/− contrast, T2/FLAIR, diffusion, and perfusion-imaging sequences are routine and provide important insight into underlying tumor activity. Nonetheless, utility of these data within and across patients, as well as across institutions, are limited by challenges in quantifying measurements accurately and lack of consistent and standardized image acquisition parameters. Currently, there exists a critical need to generate guidelines optimizing and standardizing MRI sequences for neuro-oncology patients. Additionally, more accurate differentiation of confounding factors (pseudoprogression or pseudoresponse) may be valuable. Although promising, diffusion MRI, perfusion MRI, MR spectroscopy, and amino acid PET require extensive standardization and validation. Finally, additional techniques to enhance response assessment, such as digital T1 subtraction maps, warrant further investigation. PMID:25313236

  16. Clinical image quality evaluation for panoramic radiography in Korean dental clinics

    PubMed Central

    Choi, Bo-Ram; Choi, Da-Hye; Huh, Kyung-Hoe; Yi, Won-Jin; Heo, Min-Suk; Choi, Soon-Chul; Bae, Kwang-Hak

    2012-01-01

    Purpose The purpose of this study was to investigate the level of clinical image quality of panoramic radiographs and to analyze the parameters that influence the overall image quality. Materials and Methods Korean dental clinics were asked to provide three randomly selected panoramic radiographs. An oral and maxillofacial radiology specialist evaluated those images using our self-developed Clinical Image Quality Evaluation Chart. Three evaluators classified the overall image quality of the panoramic radiographs and evaluated the causes of imaging errors. Results A total of 297 panoramic radiographs were collected from 99 dental hospitals and clinics. The mean of the scores according to the Clinical Image Quality Evaluation Chart was 79.9. In the classification of the overall image quality, 17 images were deemed 'optimal for obtaining diagnostic information,' 153 were 'adequate for diagnosis,' 109 were 'poor but diagnosable,' and nine were 'unrecognizable and too poor for diagnosis'. The results of the analysis of the causes of the errors in all the images are as follows: 139 errors in the positioning, 135 in the processing, 50 from the radiographic unit, and 13 due to anatomic abnormality. Conclusion Panoramic radiographs taken at local dental clinics generally have a normal or higher-level image quality. Principal factors affecting image quality were positioning of the patient and image density, sharpness, and contrast. Therefore, when images are taken, the patient position should be adjusted with great care. Also, standardizing objective criteria of image density, sharpness, and contrast is required to evaluate image quality effectively. PMID:23071969

  17. CCCT - NCTN Steering Committees - Clinical Imaging

    Cancer.gov

    The Clinical Imaging Steering Committee serves as a forum for the extramural imaging and oncology communities to provide strategic input to the NCI regarding its significant investment in imaging activities in clinical trials.

  18. Clinical whole-genome sequencing from routine formalin-fixed, paraffin-embedded specimens: pilot study for the 100,000 Genomes Project.

    PubMed

    Robbe, Pauline; Popitsch, Niko; Knight, Samantha J L; Antoniou, Pavlos; Becq, Jennifer; He, Miao; Kanapin, Alexander; Samsonova, Anastasia; Vavoulis, Dimitrios V; Ross, Mark T; Kingsbury, Zoya; Cabes, Maite; Ramos, Sara D C; Page, Suzanne; Dreau, Helene; Ridout, Kate; Jones, Louise J; Tuff-Lacey, Alice; Henderson, Shirley; Mason, Joanne; Buffa, Francesca M; Verrill, Clare; Maldonado-Perez, David; Roxanis, Ioannis; Collantes, Elena; Browning, Lisa; Dhar, Sunanda; Damato, Stephen; Davies, Susan; Caulfield, Mark; Bentley, David R; Taylor, Jenny C; Turnbull, Clare; Schuh, Anna

    2018-02-01

    PurposeFresh-frozen (FF) tissue is the optimal source of DNA for whole-genome sequencing (WGS) of cancer patients. However, it is not always available, limiting the widespread application of WGS in clinical practice. We explored the viability of using formalin-fixed, paraffin-embedded (FFPE) tissues, available routinely for cancer patients, as a source of DNA for clinical WGS.MethodsWe conducted a prospective study using DNAs from matched FF, FFPE, and peripheral blood germ-line specimens collected from 52 cancer patients (156 samples) following routine diagnostic protocols. We compared somatic variants detected in FFPE and matching FF samples.ResultsWe found the single-nucleotide variant agreement reached 71% across the genome and somatic copy-number alterations (CNAs) detection from FFPE samples was suboptimal (0.44 median correlation with FF) due to nonuniform coverage. CNA detection was improved significantly with lower reverse crosslinking temperature in FFPE DNA extraction (80 °C or 65 °C depending on the methods). Our final data showed somatic variant detection from FFPE for clinical decision making is possible. We detected 98% of clinically actionable variants (including 30/31 CNAs).ConclusionWe present the first prospective WGS study of cancer patients using FFPE specimens collected in a routine clinical environment proving WGS can be applied in the clinic.GENETICS in MEDICINE advance online publication, 1 February 2018; doi:10.1038/gim.2017.241.

  19. Identification and treatment of patients with nicotine problems in routine clinical psychiatry practice.

    PubMed

    Montoya, Ivan D; Herbeck, Diane M; Svikis, Dace S; Pincus, Harold Alan

    2005-01-01

    The aim of this study is to assess the rates of nicotine problems diagnosed by psychiatrists, the characteristics of psychiatric patients who smoke, and the services provided to them in routine psychiatric practice. Data were obtained by asking psychiatrists participating in the American Psychiatric Institute for Psychiatric Research and Education's Practice Research Network to complete a self-administered questionnaire to provide detailed sociodemographic, clinical, and health plan information on three of their patients seen during routine clinical practice. A total of 615 psychiatrists provided information on 1,843 patients, of which 280 (16.6%) were reported to have a current nicotine problem. Of these, 9.1% were reported to receive treatment for nicotine dependence. Patients with nicotine problems were significantly more likely to be males, divorced or separated, disabled, and uninsured, and have fewer years of education. They also had significantly more co-morbid psychiatric disorders, particularly schizophrenia or alcohol/substance use disorders; a lower Global Assessment Functioning score; and poorer treatment compliance than their counterparts. The results suggest a very low rate of identification and treatment of nicotine problems among patients treated by psychiatrists, even though psychiatric patients who smoke seem to have more clinical and psychosocial stressors and more severe psychiatric problems than those who do not smoke. Programs should be developed to raise the awareness and ability of psychiatrists to diagnose and treat patients with nicotine problems, with a particular emphasis on the increased medical and psychosocial needs of psychiatric patients who smoke.

  20. Magnetic resonance imaging based functional imaging in paediatric oncology.

    PubMed

    Manias, Karen A; Gill, Simrandip K; MacPherson, Lesley; Foster, Katharine; Oates, Adam; Peet, Andrew C

    2017-02-01

    Imaging is central to management of solid tumours in children. Conventional magnetic resonance imaging (MRI) is the standard imaging modality for tumours of the central nervous system (CNS) and limbs and is increasingly used in the abdomen. It provides excellent structural detail, but imparts limited information about tumour type, aggressiveness, metastatic potential or early treatment response. MRI based functional imaging techniques, such as magnetic resonance spectroscopy, diffusion and perfusion weighted imaging, probe tissue properties to provide clinically important information about metabolites, structure and blood flow. This review describes the role of and evidence behind these functional imaging techniques in paediatric oncology and implications for integrating them into routine clinical practice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. White matter fiber tracking computation based on diffusion tensor imaging for clinical applications.

    PubMed

    Dellani, Paulo R; Glaser, Martin; Wille, Paulo R; Vucurevic, Goran; Stadie, Axel; Bauermann, Thomas; Tropine, Andrei; Perneczky, Axel; von Wangenheim, Aldo; Stoeter, Peter

    2007-03-01

    Fiber tracking allows the in vivo reconstruction of human brain white matter fiber trajectories based on magnetic resonance diffusion tensor imaging (MR-DTI), but its application in the clinical routine is still in its infancy. In this study, we present a new software for fiber tracking, developed on top of a general-purpose DICOM (digital imaging and communications in medicine) framework, which can be easily integrated into existing picture archiving and communication system (PACS) of radiological institutions. Images combining anatomical information and the localization of different fiber tract trajectories can be encoded and exported in DICOM and Analyze formats, which are valuable resources in the clinical applications of this method. Fiber tracking was implemented based on existing line propagation algorithms, but it includes a heuristic for fiber crossings in the case of disk-shaped diffusion tensors. We successfully performed fiber tracking on MR-DTI data sets from 26 patients with different types of brain lesions affecting the corticospinal tracts. In all cases, the trajectories of the central spinal tract (pyramidal tract) were reconstructed and could be applied at the planning phase of the surgery as well as in intraoperative neuronavigation.

  2. Clinical image processing engine

    NASA Astrophysics Data System (ADS)

    Han, Wei; Yao, Jianhua; Chen, Jeremy; Summers, Ronald

    2009-02-01

    Our group provides clinical image processing services to various institutes at NIH. We develop or adapt image processing programs for a variety of applications. However, each program requires a human operator to select a specific set of images and execute the program, as well as store the results appropriately for later use. To improve efficiency, we design a parallelized clinical image processing engine (CIPE) to streamline and parallelize our service. The engine takes DICOM images from a PACS server, sorts and distributes the images to different applications, multithreads the execution of applications, and collects results from the applications. The engine consists of four modules: a listener, a router, a job manager and a data manager. A template filter in XML format is defined to specify the image specification for each application. A MySQL database is created to store and manage the incoming DICOM images and application results. The engine achieves two important goals: reduce the amount of time and manpower required to process medical images, and reduce the turnaround time for responding. We tested our engine on three different applications with 12 datasets and demonstrated that the engine improved the efficiency dramatically.

  3. Optimized imaging of the midface and orbits

    PubMed Central

    Langner, Sönke

    2015-01-01

    A variety of imaging techniques are available for imaging the midface and orbits. This review article describes the different imaging techniques based on the recent literature and discusses their impact on clinical routine imaging. Imaging protocols are presented for different diseases and the different imaging modalities. PMID:26770279

  4. The Effectiveness of Online Cognitive Behavioral Treatment in Routine Clinical Practice

    PubMed Central

    Ruwaard, Jeroen; Lange, Alfred; Schrieken, Bart; Dolan, Conor V.; Emmelkamp, Paul

    2012-01-01

    Context Randomized controlled trails have identified online cognitive behavioral therapy as an efficacious intervention in the management of common mental health disorders. Objective To assess the effectiveness of online CBT for different mental disorders in routine clinical practice. Design An uncontrolled before-after study, with measurements at baseline, posttest, 6-week follow-up, and 1-year follow-up. Participants & Setting 1500 adult patients (female: 67%; mean age: 40 years) with a GP referral for psychotherapy were treated at a Dutch online mental health clinic for symptoms of depression (n = 413), panic disorder (n = 139), posttraumatic stress (n = 478), or burnout (n = 470). Interventions Manualized, web-based, therapist-assisted CBT, of which the efficacy was previously demonstrated in a series of controlled trials. Standardized duration of treatment varied from 5 weeks (online CBT for Posttraumatic stress) to 16 weeks (online CBT for Depression). Main Outcome Measures Validated self-report questionnaires of specific and general psychopathology, including the Beck Depression Inventory, the Impact of Event Scale, the Panic Disorder Severity Scale-Self Report, the Oldenburg Burnout Inventory, and the Depression Anxiety Stress Scales. Results Treatment adherence was 71% (n = 1071). Study attrition was 21% at posttest, 33% at 6-week FU and 65% at 1-year FU. Mixed-model repeated measures regression identified large short-term reductions in all measures of primary symptoms (d = 1.9±0.2 to d = 1.2±0.2; P<.001), which sustained up to one year after treatment. At posttest, rates of reliable improvement and recovery were 71% and 52% in the completer sample (full sample: 55%/40%). Patient satisfaction was high. Conclusions Results suggest that online therapist-assisted CBT may be as effective in routine practice as it is in clinical trials. Although pre-treatment withdrawal and long-term outcomes require further study, results warrant

  5. Routine Ultrasound and Limited Computed Tomography for the Diagnosis of Acute Appendicitis

    PubMed Central

    Wiersma, Fraukje; Bakker, Rutger F. R.; Merkus, Jos W. S.; Breslau, Paul J.; Hamming, Jaap F.

    2010-01-01

    Background Acute appendicitis continues to be a challenging diagnosis. Preoperative radiological imaging using ultrasound (US) or computed tomography (CT) has gained popularity as it may offer a more accurate diagnosis than classic clinical evaluation. The optimal implementation of these diagnostic modalities has yet to be established. The aim of the present study was to investigate a diagnostic pathway that uses routine US, limited CT, and clinical re-evaluation for patients with acute appendicitis. Methods A prospective analysis was performed of all patients presenting with acute abdominal pain at the emergency department from June 2005 until July 2006 using a structured diagnosis and management flowchart. Daily practice was mimicked, while ensuring a valid assessment of clinical and radiological diagnostic accuracies and the effect they had on patient management. Results A total of 802 patients were included in this analysis. Additional radiological imaging was performed in 96.3% of patients with suspected appendicitis (n = 164). Use of CT was kept to a minimum (17.9%), with a US:CT ratio of approximately 6:1. Positive and negative predictive values for the clinical diagnosis of appendicitis were 63 and 98%, respectively; for US 94 and 97%, respectively; and for CT 100 and 100%, respectively. The negative appendicitis rate was 3.3%, the perforation rate was 23.5%, and the missed perforated appendicitis rate was 3.4%. No (diagnostic) laparoscopies were performed. Conclusions A diagnostic pathway using routine US, limited CT, and clinical re-evaluation for patients with acute abdominal pain can provide excellent results for the diagnosis and treatment of appendicitis. PMID:20582544

  6. Correlation between the signal-to-noise ratio improvement factor (KSNR) and clinical image quality for chest imaging with a computed radiography system

    NASA Astrophysics Data System (ADS)

    Moore, C. S.; Wood, T. J.; Saunderson, J. R.; Beavis, A. W.

    2015-12-01

    This work assessed the appropriateness of the signal-to-noise ratio improvement factor (KSNR) as a metric for the optimisation of computed radiography (CR) of the chest. The results of a previous study in which four experienced image evaluators graded computer simulated chest images using a visual grading analysis scoring (VGAS) scheme to quantify the benefit of using an anti-scatter grid were used for the clinical image quality measurement (number of simulated patients  =  80). The KSNR was used to calculate the improvement in physical image quality measured in a physical chest phantom. KSNR correlation with VGAS was assessed as a function of chest region (lung, spine and diaphragm/retrodiaphragm), and as a function of x-ray tube voltage in a given chest region. The correlation of the latter was determined by the Pearson correlation coefficient. VGAS and KSNR image quality metrics demonstrated no correlation in the lung region but did show correlation in the spine and diaphragm/retrodiaphragmatic regions. However, there was no correlation as a function of tube voltage in any region; a Pearson correlation coefficient (R) of  -0.93 (p  =  0.015) was found for lung, a coefficient (R) of  -0.95 (p  =  0.46) was found for spine, and a coefficient (R) of  -0.85 (p  =  0.015) was found for diaphragm. All demonstrate strong negative correlations indicating conflicting results, i.e. KSNR increases with tube voltage but VGAS decreases. Medical physicists should use the KSNR metric with caution when assessing any potential improvement in clinical chest image quality when introducing an anti-scatter grid for CR imaging, especially in the lung region. This metric may also be a limited descriptor of clinical chest image quality as a function of tube voltage when a grid is used routinely.

  7. Routine Digital Pathology Workflow: The Catania Experience.

    PubMed

    Fraggetta, Filippo; Garozzo, Salvatore; Zannoni, Gian Franco; Pantanowitz, Liron; Rossi, Esther Diana

    2017-01-01

    Successful implementation of whole slide imaging (WSI) for routine clinical practice has been accomplished in only a few pathology laboratories worldwide. We report the transition to an effective and complete digital surgical pathology workflow in the pathology laboratory at Cannizzaro Hospital in Catania, Italy. All (100%) permanent histopathology glass slides were digitized at ×20 using Aperio AT2 scanners. Compatible stain and scanning slide racks were employed to streamline operations. eSlide Manager software was bidirectionally interfaced with the anatomic pathology laboratory information system. Virtual slide trays connected to the two-dimensional (2D) barcode tracking system allowed pathologists to confirm that they were correctly assigned slides and that all tissues on these glass slides were scanned. Over 115,000 glass slides were digitized with a scan fail rate of around 1%. Drying glass slides before scanning minimized them sticking to scanner racks. Implementation required introduction of a 2D barcode tracking system and modification of histology workflow processes. Our experience indicates that effective adoption of WSI for primary diagnostic use was more dependent on optimizing preimaging variables and integration with the laboratory information system than on information technology infrastructure and ensuring pathologist buy-in. Implementation of digital pathology for routine practice not only leveraged the benefits of digital imaging but also creates an opportunity for establishing standardization of workflow processes in the pathology laboratory.

  8. Knowledge on Irradiation, Medical Imaging Prescriptions, and Clinical Imaging Referral Guidelines among Physicians in a Sub-Saharan African Country (Cameroon)

    PubMed Central

    Tene, Ulrich; Samba Ngano, Odette; Tchemtchoua Youta, Justine; Simo, Augustin; Gonsu Fotsin, Joseph

    2017-01-01

    Background Clinical imaging guidelines (CIGs) are suitable tools to enhance justification of imaging procedures. Objective To assess physicians' knowledge on irradiation, their self-perception of imaging prescriptions, and the use of CIGs. Materials and Methods A questionnaire of 21 items was self-administered between July and August 2016 to 155 referring physicians working in seven university-affiliated hospitals in Yaoundé and Douala (Cameroon). This pretested questionnaire based on imaging referral practices, the use and the need of CIGs, knowledge on radiation doses of 11 specific radiologic procedures, and knowledge of injurious effects of radiation was completed in the presence of the investigator. Scores were allocated for each question. Results 155 questionnaires were completed out of 180 administered (86.1%). Participants were 90 (58%) females, 63 (40.64%) specialists, 53 (34.20%) residents/interns, and 39 (25.16%) general practitioners. The average professional experience was 7.4 years (1–25 years). The mean knowledge score was 11.5/59 with no influence of sex, years of experience, and professional category. CIGs users' score was better than nonusers (means 14.2 versus 10.6; p < 0.01). 80% of physicians (124/155) underrated radiation doses of routine imaging exams. Seventy-eight (50.3%) participants have knowledge on CIGs and half of them made use of them. “Impact on diagnosis” was the highest justification criteria follow by “impact on treatment decision.” Unjustified requests were mainly for “patient expectation or will” or for “research motivations.” 96% of interviewees believed that making available national CIGs will improve justification. Conclusion Most physicians did not have appropriate awareness about radiation doses for routine imaging procedures. A small number of physicians have knowledge on CIGs but they believe that making available CIGs will improve justification of imaging procedures. Continuous trainings on radiation

  9. Design and Validation of a Radio-Frequency Identification-Based Device for Routinely Assessing Gait Speed in a Geriatrics Clinic.

    PubMed

    Barry, Lisa C; Hatchman, Laura; Fan, Zhaoyan; Guralnik, Jack M; Gao, Robert X; Kuchel, George A

    2018-05-01

    To evaluate the feasibility, acceptability, and validity of a radio-frequency identification (RFID)-based system to measure gait speed in a clinical setting as a first step to using unobtrusive gait speed assessment in routine clinical care. Feasibility study comparing gait speed assessed using an RFID-based system with gait speed assessed using handheld stopwatch, the criterion standard. Outpatient geriatrics clinic at a Connecticut-based academic medical center. Clinic attendees who could walk independently with or without an assistive device (N=50) and healthcare providers (N=9). Gait speed was measured in twice using 2 methods each time before participants entered an examination room. Participants walked at their usual pace while gait speed was recorded simultaneously using the RFID-based system and a handheld stopwatch operated by a trained study investigator. After 2 trials, participants completed a brief survey regarding their experience. At the end of the study period, clinic healthcare providers completed a separate survey. Test-retest reliability of the RFID-based system was high (intraclass correlation coefficient = 0.953). The mean difference ± standard deviation in gait speed between the RFID-based system and the stopwatch was -0.003±0.035 m/s (p=.53) and did not differ significantly according to age, sex, or use of an assistive walking aid. Acceptability of the device was high, and 8 of 9 providers indicated that measuring gait speed using the RFID-based system should be a part of routine clinical care. RFID technology may offer a practical means of overcoming barriers to routine measurement of gait speed in real-world outpatient clinical settings. © 2018, Copyright the Authors Journal compilation © 2018, The American Geriatrics Society.

  10. Optimization of a simultaneous dual-isotope 201Tl/123I-MIBG myocardial SPECT imaging protocol with a CZT camera for trigger zone assessment after myocardial infarction for routine clinical settings: Are delayed acquisition and scatter correction necessary?

    PubMed

    D'estanque, Emmanuel; Hedon, Christophe; Lattuca, Benoît; Bourdon, Aurélie; Benkiran, Meriem; Verd, Aurélie; Roubille, François; Mariano-Goulart, Denis

    2017-08-01

    Dual-isotope 201 Tl/ 123 I-MIBG SPECT can assess trigger zones (dysfunctions in the autonomic nervous system located in areas of viable myocardium) that are substrate for ventricular arrhythmias after STEMI. This study evaluated the necessity of delayed acquisition and scatter correction for dual-isotope 201 Tl/ 123 I-MIBG SPECT studies with a CZT camera to identify trigger zones after revascularization in patients with STEMI in routine clinical settings. Sixty-nine patients were prospectively enrolled after revascularization to undergo 201 Tl/ 123 I-MIBG SPECT using a CZT camera (Discovery NM 530c, GE). The first acquisition was a single thallium study (before MIBG administration); the second and the third were early and late dual-isotope studies. We compared the scatter-uncorrected and scatter-corrected (TEW method) thallium studies with the results of magnetic resonance imaging or transthoracic echography (reference standard) to diagnose myocardial necrosis. Summed rest scores (SRS) were significantly higher in the delayed MIBG studies than the early MIBG studies. SRS and necrosis surface were significantly higher in the delayed thallium studies with scatter correction than without scatter correction, leading to less trigger zone diagnosis for the scatter-corrected studies. Compared with the scatter-uncorrected studies, the late thallium scatter-corrected studies provided the best diagnostic values for myocardial necrosis assessment. Delayed acquisitions and scatter-corrected dual-isotope 201 Tl/ 123 I-MIBG SPECT acquisitions provide an improved evaluation of trigger zones in routine clinical settings after revascularization for STEMI.

  11. Predicting the evolution of low back pain patients in routine clinical practice: results from a registry within the Spanish National Health Service.

    PubMed

    Kovacs, Francisco M; Seco, Jesús; Royuela, Ana; Corcoll Reixach, Josep; Abraira, Víctor

    2012-11-01

    The Spanish National Health Service (SNHS) is a tax-funded public organization that provides free health care to every resident in Spain. To develop models for predicting the evolution of low back pain (LBP) in routine clinical practice within SNHS. Analysis of a prospective registry in routine clinical practice, in 17 centers across SNHS. Patient sample includes 4,477 acute and chronic LBP patients treated in primary and hospital care. Pain and disability, measured through validated instruments. Patients treated for LBP were assessed at baseline and 3 months later. Data gathered were the following: sex, age, employment status, duration of pain, severity of LBP, pain down to the leg (LP) and disability, history of lumbar surgery, diagnostic procedures undertaken, imaging findings, and treatments used throughout the study period. Three separate multivariate logistic regression models were developed for predicting a clinically relevant improvement in LBP, LP, and disability at 3 months. In total, 4,261 patients (95.2%) attended follow-up. For all the models, calibration was reasonable and the area under the receiver operating characteristic curve was ≥0.640. For LBP, LP, and disability, factors associated with a higher probability of improvement at 3 months were the following: not having undergone lumbar surgery, higher baseline scores for the corresponding variable, lower ones for the rest, and being treated with neuroreflexotherapy. Additional factors were the following: for LBP, shorter pain duration; for LP, not undergoing electromyography; and for disability, shorter pain duration, not being diagnosed with disc degeneration, and being treated with muscle relaxants and not opioids. A prospective registry can be used for developing predictive models to quantify the odds that a given LBP patient will experience a clinically relevant improvement. This may empower patients for an informed shared decision making. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Clinical, electrophysiological and magnetic resonance imaging findings in carpal tunnel syndrome.

    PubMed

    Musluoğlu, L; Celik, M; Tabak, H; Forta, H

    2004-01-01

    To assess magnetic resonance imaging (MRI) findings in carpal tunnel syndrome (CTS) and to compare them with electrophysiological findings. Routine motor and sensory nerve conduction examinations and needle EMG were performed in 42 hands of 22 patients, who were clinically diagnosed as having CTS in at least one wrist. Of 29 wrists with clinically and electrophysiologically confirmed CTS, MRI could detect abnormality in 18 wrists (62%). Median nerve was found to be abnormal in MRI in 1 of 2 wrists with suspected clinical symptoms and proven CTS by electrophysiological examination. MRI was abnormal in 1 of 4 wrists with normal clinical and electrophysiological examination. MRI was abnormal in 46, 7% of wrists with mild CTS, in 61.6% of moderate CTS and in 100% of severe CTS. Volar bulging of the flexor retinaculum was detected in a single wrist with severe CTS. Enlargement of median nerve was observed in 3 of 5 severe CTS. MRI could be useful in the diagnosis of unproven cases in CTS. It also provides anatomical information that correlate well with electrophysiological findings in regard of the severity of median nerve compression.

  13. Integration of CBIR in radiological routine in accordance with IHE

    NASA Astrophysics Data System (ADS)

    Welter, Petra; Deserno, Thomas M.; Fischer, Benedikt; Wein, Berthold B.; Ott, Bastian; Günther, Rolf W.

    2009-02-01

    Increasing use of digital imaging processing leads to an enormous amount of imaging data. The access to picture archiving and communication systems (PACS), however, is solely textually, leading to sparse retrieval results because of ambiguous or missing image descriptions. Content-based image retrieval (CBIR) systems can improve the clinical diagnostic outcome significantly. However, current CBIR systems are not able to integrate their results with clinical workflow and PACS. Existing communication standards like DICOM and HL7 leave many options for implementation and do not ensure full interoperability. We present a concept of the standardized integration of a CBIR system for the radiology workflow in accordance with the Integrating the Healthcare Enterprise (IHE) framework. This is based on the IHE integration profile 'Post-Processing Workflow' (PPW) defining responsibilities as well as standardized communication and utilizing the DICOM Structured Report (DICOM SR). Because nowadays most of PACS and RIS systems are not yet fully IHE compliant to PPW, we also suggest an intermediate approach with the concepts of the CAD-PACS Toolkit. The integration is independent of the particular PACS and RIS system. Therefore, it supports the widespread application of CBIR in radiological routine. As a result, the approach is exemplarily applied to the Image Retrieval in Medical Applications (IRMA) framework.

  14. Reproducibility of Alzheimer’s Disease Cerebrospinal Fluid-Biomarker Measurements under Clinical Routine Conditions

    PubMed Central

    Vogelgsang, Jonathan; Wedekind, Dirk; Bouter, Caroline; Klafki, Hans-W.; Wiltfang, Jens

    2018-01-01

    Analysis of cerebrospinal fluid (CSF) is one of the key tools for the state-of-the-art differential diagnosis of dementias. Dementia due to Alzheimer’s disease (AD) is characterized by elevated CSF levels of total Tau (tTau) and phospho-181-Tau (pTau) and low CSF amyloid-β42 (Aβ42). Discrepancies in the laboratory analysis of human materials are well known and much effort has been put into harmonization procedures. In this study, we measured CSF biomarkers of more than 100 patients obtained under clinical routine conditions in two different clinical laboratories. The CSF biomarker levels obtained from the two different sites were significantly correlated: R2 = 0.7129 (tTau, p < 0.001), 0.7914 (pTau, p < 0.001), 0.5078 (Aβ42, p < 0.001), 0.5739 (Aβ40, p < 0.001), and 0.4308 (Aβ42/40, p < 0.001). However, the diagnostic classifications of the Aβ42, tTau, and pTau levels of identical subjects into normal versus pathological range made by the two different sites showed substantial discrepancies (31.5%, 29.6%, and 25.0% discordant cases, respectively). Applying Aβ42/40, instead of CSF Aβ42 alone, lead to a reduction of the discordant cases to 16.8%. Our findings suggest that CSF Aβ42/40 can outperform Aβ42 as a biomarker for AD neuropathology, not only under well-controlled study conditions but also in real life clinical routine. Thus, we recommend the inclusion of Aβ42/40 as a CSF biomarker in the diagnostic procedure. PMID:29439341

  15. Cost Effectiveness Analysis of Clinically Driven versus Routine Laboratory Monitoring of Antiretroviral Therapy in Uganda and Zimbabwe

    PubMed Central

    Medina Lara, Antonieta; Kigozi, Jesse; Amurwon, Jovita; Muchabaiwa, Lazarus; Nyanzi Wakaholi, Barbara; Mujica Mota, Ruben E.; Walker, A. Sarah; Kasirye, Ronnie; Ssali, Francis; Reid, Andrew; Grosskurth, Heiner; Babiker, Abdel G.; Kityo, Cissy; Katabira, Elly; Munderi, Paula; Mugyenyi, Peter; Hakim, James; Darbyshire, Janet; Gibb, Diana M.; Gilks, Charles F.

    2012-01-01

    Background Despite funding constraints for treatment programmes in Africa, the costs and economic consequences of routine laboratory monitoring for efficacy and toxicity of antiretroviral therapy (ART) have rarely been evaluated. Methods Cost-effectiveness analysis was conducted in the DART trial (ISRCTN13968779). Adults in Uganda/Zimbabwe starting ART were randomised to clinically-driven monitoring (CDM) or laboratory and clinical monitoring (LCM); individual patient data on healthcare resource utilisation and outcomes were valued with primary economic costs and utilities. Total costs of first/second-line ART, routine 12-weekly CD4 and biochemistry/haematology tests, additional diagnostic investigations, clinic visits, concomitant medications and hospitalisations were considered from the public healthcare sector perspective. A Markov model was used to extrapolate costs and benefits 20 years beyond the trial. Results 3316 (1660LCM;1656CDM) symptomatic, immunosuppressed ART-naive adults (median (IQR) age 37 (32,42); CD4 86 (31,139) cells/mm3) were followed for median 4.9 years. LCM had a mean 0.112 year (41 days) survival benefit at an additional mean cost of $765 [95%CI:685,845], translating into an adjusted incremental cost of $7386 [3277,dominated] per life-year gained and $7793 [4442,39179] per quality-adjusted life year gained. Routine toxicity tests were prominent cost-drivers and had no benefit. With 12-weekly CD4 monitoring from year 2 on ART, low-cost second-line ART, but without toxicity monitoring, CD4 test costs need to fall below $3.78 to become cost-effective (<3xper-capita GDP, following WHO benchmarks). CD4 monitoring at current costs as undertaken in DART was not cost-effective in the long-term. Conclusions There is no rationale for routine toxicity monitoring, which did not affect outcomes and was costly. Even though beneficial, there is little justification for routine 12-weekly CD4 monitoring of ART at current test costs in low-income African

  16. Machine Learning in Medical Imaging.

    PubMed

    Giger, Maryellen L

    2018-03-01

    Advances in both imaging and computers have synergistically led to a rapid rise in the potential use of artificial intelligence in various radiological imaging tasks, such as risk assessment, detection, diagnosis, prognosis, and therapy response, as well as in multi-omics disease discovery. A brief overview of the field is given here, allowing the reader to recognize the terminology, the various subfields, and components of machine learning, as well as the clinical potential. Radiomics, an expansion of computer-aided diagnosis, has been defined as the conversion of images to minable data. The ultimate benefit of quantitative radiomics is to (1) yield predictive image-based phenotypes of disease for precision medicine or (2) yield quantitative image-based phenotypes for data mining with other -omics for discovery (ie, imaging genomics). For deep learning in radiology to succeed, note that well-annotated large data sets are needed since deep networks are complex, computer software and hardware are evolving constantly, and subtle differences in disease states are more difficult to perceive than differences in everyday objects. In the future, machine learning in radiology is expected to have a substantial clinical impact with imaging examinations being routinely obtained in clinical practice, providing an opportunity to improve decision support in medical image interpretation. The term of note is decision support, indicating that computers will augment human decision making, making it more effective and efficient. The clinical impact of having computers in the routine clinical practice may allow radiologists to further integrate their knowledge with their clinical colleagues in other medical specialties and allow for precision medicine. Copyright © 2018. Published by Elsevier Inc.

  17. Clinical skin imaging using color spatial frequency domain imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Yang, Bin; Lesicko, John; Moy, Austin J.; Reichenberg, Jason; Tunnell, James W.

    2016-02-01

    Skin diseases are typically associated with underlying biochemical and structural changes compared with normal tissues, which alter the optical properties of the skin lesions, such as tissue absorption and scattering. Although widely used in dermatology clinics, conventional dermatoscopes don't have the ability to selectively image tissue absorption and scattering, which may limit its diagnostic power. Here we report a novel clinical skin imaging technique called color spatial frequency domain imaging (cSFDI) which enhances contrast by rendering color spatial frequency domain (SFD) image at high spatial frequency. Moreover, by tuning spatial frequency, we can obtain both absorption weighted and scattering weighted images. We developed a handheld imaging system specifically for clinical skin imaging. The flexible configuration of the system allows for better access to skin lesions in hard-to-reach regions. A total of 48 lesions from 31 patients were imaged under 470nm, 530nm and 655nm illumination at a spatial frequency of 0.6mm^(-1). The SFD reflectance images at 470nm, 530nm and 655nm were assigned to blue (B), green (G) and red (R) channels to render a color SFD image. Our results indicated that color SFD images at f=0.6mm-1 revealed properties that were not seen in standard color images. Structural features were enhanced and absorption features were reduced, which helped to identify the sources of the contrast. This imaging technique provides additional insights into skin lesions and may better assist clinical diagnosis.

  18. Effects of probiotic supplementation over 5 months on routine haematology and clinical chemistry measures in healthy active adults.

    PubMed

    Cox, A J; West, N P; Horn, P L; Lehtinen, M J; Koerbin, G; Pyne, D B; Lahtinen, S J; Fricker, P A; Cripps, A W

    2014-11-01

    Use of probiotic-containing foods and probiotic supplements is increasing; however, few studies document safety and tolerability in conjunction with defined clinical end points. This paper reports the effects of 150 days of supplementation with either a single- (Bifidobacterium animalis subsp. lactis Bl-04) or a double-strain (Lactobacillus acidophilus NCFM and Bifidobacterium animalis subsp. lactis Bi-07) probiotic on routine haematology and clinical chemistry measures in healthy active adults. Pre- to post-intervention changes in laboratory measures were determined and compared between supplement and placebo groups. Overall there were few differences in routine haematology and clinical chemistry measures between supplement and placebo groups post-intervention. Exceptions included plasma calcium (P=0.03) and urea (P=0.015); however, observed changes were small and within assay-specific laboratory reference ranges. These data provide evidence supporting the use of these probiotic supplements over a period of 5 months in healthy active adults without obvious safety or tolerability issues.

  19. Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCowan, P. M., E-mail: pmccowan@cancercare.mb.ca; McCurdy, B. M. C.; Medical Physics Department, CancerCare Manitoba, 675 McDermot Avenue, Winnipeg, Manitoba R3E 0V9

    Purpose: The in vivo 3D dose delivered to a patient during volumetric modulated arc therapy (VMAT) delivery can be calculated using electronic portal imaging device (EPID) images. These images must be acquired in cine-mode (i.e., “movie” mode) in order to capture the time-dependent delivery information. The angle subtended by each cine-mode EPID image during an arc can be changed via the frame averaging number selected within the image acquisition software. A large frame average number will decrease the EPID’s angular resolution and will result in a decrease in the accuracy of the dose information contained within each image. Alternatively, lessmore » EPID images acquired per delivery will decrease the overall 3D patient dose calculation time, which is appealing for large-scale clinical implementation. Therefore, the purpose of this study was to determine the optimal frame average value per EPID image, defined as the highest frame averaging that can be used without an appreciable loss in 3D dose reconstruction accuracy for VMAT treatments. Methods: Six different VMAT plans and six different SBRT-VMAT plans were delivered to an anthropomorphic phantom. Delivery was carried out on a Varian 2300ix model linear accelerator (Linac) equipped with an aS1000 EPID running at a frame acquisition rate of 7.5 Hz. An additional PC was set up at the Linac console area, equipped with specialized frame-grabber hardware and software packages allowing continuous acquisition of all EPID frames during delivery. Frames were averaged into “frame-averaged” EPID images using MATLAB. Each frame-averaged data set was used to calculate the in vivo dose to the patient and then compared to the single EPID frame in vivo dose calculation (the single frame calculation represents the highest possible angular resolution per EPID image). A mean percentage dose difference of low dose (<20% prescription dose) and high dose regions (>80% prescription dose) was calculated for each frame

  20. The impact of routine surveillance screening with magnetic resonance imaging (MRI) to detect tumour recurrence in children with central nervous system (CNS) tumours: protocol for a systematic review and meta-analysis.

    PubMed

    Main, Caroline; Stevens, Simon P; Bailey, Simon; Phillips, Robert; Pizer, Barry; Wheatley, Keith; Kearns, Pamela R; English, Martin; Wilne, Sophie; Wilson, Jayne S

    2016-08-31

    The aim of this study is to assess the impact of routine MRI surveillance to detect tumour recurrence in children with no new neurological signs or symptoms compared with alternative follow-up practices, including periodic clinical and physical examinations and the use of non-routine imaging upon presentation with disease signs or symptoms. Standard systematic review methods aimed at minimising bias will be employed for study identification, selection and data extraction. Ten electronic databases have been searched, and further citation searching and reference checking will be employed. Randomised and non-randomised controlled trials assessing the impact of routine surveillance MRI to detect tumour recurrence in children with no new neurological signs or symptoms compared to alternative follow-up schedules including imaging upon presentation with disease signs or symptoms will be included. The primary outcome is time to change in therapeutic intervention. Secondary outcomes include overall survival, surrogate survival outcomes, response rates, diagnostic yield per set of images, adverse events, quality of survival and validated measures of family psychological functioning and anxiety. Two reviewers will independently screen and select studies for inclusion. Quality assessment will be undertaken using the Cochrane Collaboration's tools for assessing risk of bias. Where possible, data will be summarised using combined estimates of effect for time to treatment change, survival outcomes and response rates using assumption-free methods. Further sub-group analyses and meta-regression models will be specified and undertaken to explore potential sources of heterogeneity between studies within each tumour type if necessary. Assessment of the impact of surveillance imaging in children with CNS tumours is methodologically complex. The evidence base is likely to be heterogeneous in terms of imaging protocols, definitions of radiological response and diagnostic accuracy of

  1. Routine upper gastrointestinal Gastrografin swallow after laparoscopic Roux-en-Y gastric bypass.

    PubMed

    Sims, Thomas L; Mullican, Mary A; Hamilton, Elizabeth C; Provost, David A; Jones, Daniel B

    2003-02-01

    Upper gastrointestinal (UGI) swallow radiographs following laparoscopic Roux-en-Y gastric bypass (LRYGBP) may detect an obstruction or an anastomotic leak. The aim of our study was to determine the efficacy of routine imaging following LRYGBP. Radiograph reports were reviewed for 201 consecutive LRYGBP operations between April 1999 and June 2001. UGI swallow used Gastrografin, static films, fluoroscopic video, and a delayed image at 10 minutes. Mean values with one standard deviation were tested for significance (P < 0.05) using the Mann-Whitney U test statistic. Of 198 available reports, UGI detected jejunal efferent (Roux) limb narrowing (n = 17), partial obstruction (n = 12), anastomotic leak (n = 3), complete bowel obstruction (n = 3), diverticulum (n = 1), hiatal hernia (n = 1), and proximal Roux limb narrowing (n = 1). A normal study was reported in 160 cases (81%). Partial obstruction resolved without intervention. Complete obstruction required re-operation. Compared to 6 patients who developed delayed leaks, early identification of a leak by routine UGI swallow resulted in a shorter hospital stay (mean 7.7 +/- 1.5 days vs 40.2 +/- 12.3 days, P < 0.03). Early intervention after UGI swallow may lessen morbidity. Routine UGI swallow following LRYGBP does not obviate the importance of close clinical follow-up.

  2. Ultrasound Molecular Imaging: Moving Towards Clinical Translation

    PubMed Central

    Abou-Elkacem, Lotfi; Bachawal, Sunitha V.; Willmann, Jürgen K.

    2015-01-01

    Ultrasound is a widely available, cost-effective, real-time, non-invasive and safe imaging modality widely used in the clinic for anatomical and functional imaging. With the introduction of novel molecularly-targeted ultrasound contrast agents, another dimension of ultrasound has become a reality: diagnosing and monitoring pathological processes at the molecular level. Most commonly used ultrasound molecular imaging contrast agents are micron sized, gas-containing microbubbles functionalized to recognize and attach to molecules expressed on inflamed or angiogenic vascular endothelial cells. There are several potential clinical applications currently being explored including earlier detection, molecular profiling, and monitoring of cancer, as well as visualization of ischemic memory in transient myocardial ischemia, monitoring of disease activity in inflammatory bowel disease, and assessment of arteriosclerosis. Recently, a first clinical grade ultrasound contrast agent (BR55), targeted at a molecule expressed in neoangiogenesis (vascular endothelial growth factor receptor type 2; VEGFR2) has been introduced and safety and feasibility of VEGFR2-targeted ultrasound imaging is being explored in first inhuman clinical trials in various cancer types. This review describes the design of ultrasound molecular imaging contrast agents, imaging techniques, and potential future clinical applications of ultrasound molecular imaging. PMID:25851932

  3. A data grid for imaging-based clinical trials

    NASA Astrophysics Data System (ADS)

    Zhou, Zheng; Chao, Sander S.; Lee, Jasper; Liu, Brent; Documet, Jorge; Huang, H. K.

    2007-03-01

    Clinical trials play a crucial role in testing new drugs or devices in modern medicine. Medical imaging has also become an important tool in clinical trials because images provide a unique and fast diagnosis with visual observation and quantitative assessment. A typical imaging-based clinical trial consists of: 1) A well-defined rigorous clinical trial protocol, 2) a radiology core that has a quality control mechanism, a biostatistics component, and a server for storing and distributing data and analysis results; and 3) many field sites that generate and send image studies to the radiology core. As the number of clinical trials increases, it becomes a challenge for a radiology core servicing multiple trials to have a server robust enough to administrate and quickly distribute information to participating radiologists/clinicians worldwide. The Data Grid can satisfy the aforementioned requirements of imaging based clinical trials. In this paper, we present a Data Grid architecture for imaging-based clinical trials. A Data Grid prototype has been implemented in the Image Processing and Informatics (IPI) Laboratory at the University of Southern California to test and evaluate performance in storing trial images and analysis results for a clinical trial. The implementation methodology and evaluation protocol of the Data Grid are presented.

  4. Rotigotine transdermal patch in combination therapy for Parkinson's disease--observations in routine clinical practice.

    PubMed

    Ceballos-Baumann, Andres; Häck, Hermann-Josef

    2011-10-01

    The dopamine agonist rotigotine has shown efficacy and safety for the treatment of early and advanced Parkinson's disease (PD) in controlled clinical trials. This observational study evaluated rotigotine administration in combination with other antiparkinsonian medication in routine clinical practice. Data were collected by 688 German practice-based neurologists, initiating rotigotine treatment in patients with idiopathic Parkinson's disease. Assessments included rotigotine maintenance dose, changes in concomitant PD medication, changes in sleep quality, and rotigotine tolerability over an observation period of 12-16 weeks. The median rotigotine maintenance dose was 6 mg/24 h (n = 969, full analysis set). The proportion of all other prescribed PD medications declined over the observation period; combination therapy decreased by 18.7%. Daily levodopa intake was markedly reduced by 87 mg (18.9%) in 47.6% of the patients with levodopa documentation; 7% no longer required levodopa after 12-16 weeks. Mean overall sleep quality (PD Sleep Scale item 1) improved by 21.4 points, the occurrence of nocturias (PDSS item 8) by 13.4 points, and 'turning in bed' (Unified Parkinson's Disease Rating Scale part II) by 0.6 points. Drug-related adverse events were reported for 7.9% of all patients (n = 1152, safety population). Application site reactions were the most common adverse events (2.2%) resulting in early discontinuation in 1.4% of patients. In routine clinical practice, treatment initiation with rotigotine transdermal patch was associated with a reduction of other prescribed PD medications and with an improvement of self-reported sleep quality.

  5. Issues in using whole slide imaging for diagnostic pathology: "routine" stains, immunohistochemistry and predictive markers.

    PubMed

    Taylor, C R

    2014-08-01

    The traditional microscope, together with the "routine" hematoxylin and eosin (H & E) stain, remains the "gold standard" for diagnosis of cancer and other diseases; remarkably, it and the majority of associated biological stains are more than 150 years old. Immunohistochemistry has added to the repertoire of "stains" available. Because of the need for specific identification and even measurement of "biomarkers," immunohistochemistry has increased the demand for consistency of performance and interpretation of staining results. Rapid advances in the capabilities of digital imaging hardware and software now offer a realistic route to improved reproducibility, accuracy and quantification by utilizing whole slide digital images for diagnosis, education and research. There also are potential efficiencies in work flow and the promise of powerful new analytical methods; however, there also are challenges with respect to validation of the quality and fidelity of digital images, including the standard H & E stain, so that diagnostic performance by pathologists is not compromised when they rely on whole slide images instead of traditional stained tissues on glass slides.

  6. Routine Digital Pathology Workflow: The Catania Experience

    PubMed Central

    Fraggetta, Filippo; Garozzo, Salvatore; Zannoni, Gian Franco; Pantanowitz, Liron; Rossi, Esther Diana

    2017-01-01

    Introduction: Successful implementation of whole slide imaging (WSI) for routine clinical practice has been accomplished in only a few pathology laboratories worldwide. We report the transition to an effective and complete digital surgical pathology workflow in the pathology laboratory at Cannizzaro Hospital in Catania, Italy. Methods: All (100%) permanent histopathology glass slides were digitized at ×20 using Aperio AT2 scanners. Compatible stain and scanning slide racks were employed to streamline operations. eSlide Manager software was bidirectionally interfaced with the anatomic pathology laboratory information system. Virtual slide trays connected to the two-dimensional (2D) barcode tracking system allowed pathologists to confirm that they were correctly assigned slides and that all tissues on these glass slides were scanned. Results: Over 115,000 glass slides were digitized with a scan fail rate of around 1%. Drying glass slides before scanning minimized them sticking to scanner racks. Implementation required introduction of a 2D barcode tracking system and modification of histology workflow processes. Conclusion: Our experience indicates that effective adoption of WSI for primary diagnostic use was more dependent on optimizing preimaging variables and integration with the laboratory information system than on information technology infrastructure and ensuring pathologist buy-in. Implementation of digital pathology for routine practice not only leveraged the benefits of digital imaging but also creates an opportunity for establishing standardization of workflow processes in the pathology laboratory. PMID:29416914

  7. Ultrasound molecular imaging: Moving toward clinical translation.

    PubMed

    Abou-Elkacem, Lotfi; Bachawal, Sunitha V; Willmann, Jürgen K

    2015-09-01

    Ultrasound is a widely available, cost-effective, real-time, non-invasive and safe imaging modality widely used in the clinic for anatomical and functional imaging. With the introduction of novel molecularly-targeted ultrasound contrast agents, another dimension of ultrasound has become a reality: diagnosing and monitoring pathological processes at the molecular level. Most commonly used ultrasound molecular imaging contrast agents are micron sized, gas-containing microbubbles functionalized to recognize and attach to molecules expressed on inflamed or angiogenic vascular endothelial cells. There are several potential clinical applications currently being explored including earlier detection, molecular profiling, and monitoring of cancer, as well as visualization of ischemic memory in transient myocardial ischemia, monitoring of disease activity in inflammatory bowel disease, and assessment of arteriosclerosis. Recently, a first clinical grade ultrasound contrast agent (BR55), targeted at a molecule expressed in neoangiogenesis (vascular endothelial growth factor receptor type 2; VEGFR2) has been introduced and safety and feasibility of VEGFR2-targeted ultrasound imaging is being explored in first inhuman clinical trials in various cancer types. This review describes the design of ultrasound molecular imaging contrast agents, imaging techniques, and potential future clinical applications of ultrasound molecular imaging. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, S; Wang, Y; Weng, H

    Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiationmore » dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle.« less

  9. Rheumatoid myositis, myth or reality? A clinical, imaging and histological study.

    PubMed

    Ancuţa, Codrina; Pomîrleanu, Daniela Cristina; Anton, Carmen Rodica; Moraru, Eovelina; Anton, Emil; Chirieac, Rodica Marieta; Ancuţa, Eugen

    2014-01-01

    Rheumatoid myositis (RM) is still poorly characterized, albeit the concept of muscle involvement in rheumatoid arthritis (RA) is well-recognized as being driven by a wide range of causes including inflammation, drugs, impaired joint flexibility, sedentarism. To describe clinical, serological, imaging and histological pattern of RM. This is a retrospective study on eight RM selected from a cohort of one hundred and three RA systematically assessed for skeletal muscle involvement. Data collected included clinical, serum muscle enzymes, muscle imaging and biopsy (Hematoxylin-Eosin, modified Gömöri trichrome staining). Routine muscle histology indicated both non-specific muscle fiber damage (changes in fiber size and internal structure: pleomorphic mitochondria, dilated sarcotubular system, multiple internal or subsarcommal nuclei; abnormal fiber types distribution: trend towards type II; atrophy; degenerative/regenerative modifications) and the presence of inflammatory deposits in all patients (mild to moderate, patchy B- and T-cells infiltrates, mainly perivascular and endomysial, but also in the perimysial region classified as polymyositis-like deposits). High levels of serum muscle enzymes, abnormal EMG (short duration, small amplitude, polyphasic motor unit action potentials) without insertional activity and fibrillations, active inflammation on both Doppler ultrasound and MRI were commonly reported. Traditional analysis of muscle biopsy specimens (Hematoxylin-Eosin, modified Gömöri trichrome staining) is faraway unsatisfactory, only documenting changes in muscle fibers size, architecture, internal structure, and, possibly, detecting perivascular, perimysial or endomysial inflammatory deposits. Upcoming research should address the value of muscle imaging for the diagnosis and evaluation of treatment response and muscle function in rheumatoid myositis.

  10. Modifying the Clinical Outcomes in Routine Evaluation Measure for Use with People Who Have a Learning Disability

    ERIC Educational Resources Information Center

    Marshall, Keith; Willoughby-Booth, Simon

    2007-01-01

    There are few reliable self-report measures suitable for people with a learning disability in reporting psychological distress. This study examines the modification of the Clinical Outcomes in Routine Evaluation-Outcome Measure (CORE-OM), exploring its reliability, using two different presentation styles. One style included a sequencing task then…

  11. Gene expression profiling in multiple myeloma--reporting of entities, risk, and targets in clinical routine.

    PubMed

    Meissner, Tobias; Seckinger, Anja; Rème, Thierry; Hielscher, Thomas; Möhler, Thomas; Neben, Kai; Goldschmidt, Hartmut; Klein, Bernard; Hose, Dirk

    2011-12-01

    Multiple myeloma is an incurable malignant plasma cell disease characterized by survival ranging from several months to more than 15 years. Assessment of risk and underlying molecular heterogeneity can be excellently done by gene expression profiling (GEP), but its way into clinical routine is hampered by the lack of an appropriate reporting tool and the integration with other prognostic factors into a single "meta" risk stratification. The GEP-report (GEP-R) was built as an open-source software developed in R for gene expression reporting in clinical practice using Affymetrix microarrays. GEP-R processes new samples by applying a documentation-by-value strategy to the raw data to be able to assign thresholds and grouping algorithms defined on a reference cohort of 262 patients with multiple myeloma. Furthermore, we integrated expression-based and conventional prognostic factors within one risk stratification (HM-metascore). The GEP-R comprises (i) quality control, (ii) sample identity control, (iii) biologic classification, (iv) risk stratification, and (v) assessment of target genes. The resulting HM-metascore is defined as the sum over the weighted factors gene expression-based risk-assessment (UAMS-, IFM-score), proliferation, International Staging System (ISS) stage, t(4;14), and expression of prognostic target genes (AURKA, IGF1R) for which clinical grade inhibitors exist. The HM-score delineates three significantly different groups of 13.1%, 72.1%, and 14.7% of patients with a 6-year survival rate of 89.3%, 60.6%, and 18.6%, respectively. GEP reporting allows prospective assessment of risk and target gene expression and integration of current prognostic factors in clinical routine, being customizable about novel parameters or other cancer entities. ©2011 AACR.

  12. Clinical decision making and outcome in routine care for people with severe mental illness (CEDAR): study protocol.

    PubMed

    Puschner, Bernd; Steffen, Sabine; Slade, Mike; Kaliniecka, Helena; Maj, Mario; Fiorillo, Andrea; Munk-Jørgensen, Povl; Larsen, Jens Ivar; Egerházi, Anikó; Nemes, Zoltan; Rössler, Wulf; Kawohl, Wolfram; Becker, Thomas

    2010-11-10

    A considerable amount of research has been conducted on clinical decision making (CDM) in short-term physical conditions. However, there is a lack of knowledge on CDM and its outcome in long-term illnesses, especially in care for people with severe mental illness. The study entitled "Clinical decision making and outcome in routine care for people with severe mental illness" (CEDAR) is carried out in six European countries (Denmark, Germany, Hungary, Italy, Switzerland and UK). First, CEDAR establishes a methodology to assess CDM in people with severe mental illness. Specific instruments are developed (and psychometric properties established) to measure CDM style, key elements of CDM in routine care, as well as CDM involvement and satisfaction from patient and therapist perspectives. Second, these instruments are being put to use in a multi-national prospective observational study (bimonthly assessments during a one-year observation period; N = 560). This study investigates the immediate, short- and long-term effect of CDM on crucial dimensions of clinical outcome (symptom level, quality of life, needs) by taking into account significant variables moderating the relationship between CDM and outcome. The results of this study will make possible to delineate quality indicators of CDM, as well as to specify prime areas for further improvement. Ingredients of best practice in CDM in the routine care for people with severe mental illness will be extracted and recommendations formulated. With its explicit focus on the patient role in CDM, CEDAR will also contribute to strengthening the service user perspective. This project will substantially add to improving the practice of CDM in mental health care across Europe. ISRCTN75841675.

  13. Setup in a clinical workflow and impact on radiotherapy routine of an in vivo dosimetry procedure with an electronic portal imaging device

    PubMed Central

    Piermattei, Angelo; Kang, Shengwei; Xiao, Mingyong; Tang, Bin; Liao, Xiongfei; Xin, Xin; Grusio, Mattia

    2018-01-01

    High conformal techniques such as intensity-modulated radiation therapy and volumetric-modulated arc therapy are widely used in overloaded radiotherapy departments. In vivo dosimetric screening is essential in this environment to avoid important dosimetric errors. This work examines the feasibility of introducing in vivo dosimetry (IVD) checks in a radiotherapy routine. The causes of dosimetric disagreements between delivered and planned treatments were identified and corrected during the course of treatment. The efficiency of the corrections performed and the added workload needed for the entire procedure were evaluated. The IVD procedure was based on an electronic portal imaging device. A total of 3682 IVD tests were performed for 147 patients who underwent head and neck, abdomen, pelvis, breast, and thorax radiotherapy treatments. Two types of indices were evaluated and used to determine if the IVD tests were within tolerance levels: the ratio R between the reconstructed and planned isocentre doses and a transit dosimetry based on the γ-analysis of the electronic portal images. The causes of test outside tolerance level were investigated and corrected and IVD test was repeated during subsequent fraction. The time needed for each step of the IVD procedure was registered. Pelvis, abdomen, and head and neck treatments had 10% of tests out of tolerance whereas breast and thorax treatments accounted for up to 25%. The patient setup was the main cause of 90% of the IVD tests out of tolerance and the remaining 10% was due to patient morphological changes. An average time of 42 min per day was sufficient to monitor a daily workload of 60 patients in treatment. This work shows that IVD performed with an electronic portal imaging device is feasible in an overloaded department and enables the timely realignment of the treatment quality indices in order to achieve a patient’s final treatment compliant with the one prescribed. PMID:29432473

  14. Advances in Clinical and Biomedical Applications of Photoacoustic Imaging

    PubMed Central

    Su, Jimmy L.; Wang, Bo; Wilson, Katheryne E.; Bayer, Carolyn L.; Chen, Yun-Sheng; Kim, Seungsoo; Homan, Kimberly A.; Emelianov, Stanislav Y.

    2010-01-01

    Importance of the field Photoacoustic imaging is an imaging modality that derives image contrast from the optical absorption coefficient of the tissue being imaged. The imaging technique is able to differentiate between healthy and diseased tissue with either deeper penetration or higher resolution than other functional imaging modalities currently available. From a clinical standpoint, photoacoustic imaging has demonstrated safety and effectiveness in diagnosing diseased tissue regions using either endogenous tissue contrast or exogenous contrast agents. Furthermore, the potential of photoacoustic imaging has been demonstrated in various therapeutic interventions ranging from drug delivery and release to image-guided therapy and monitoring. Areas covered in this review This article reviews the current state of photoacoustic imaging in biomedicine from a technological perspective, highlights various biomedical and clinical applications of photoacoustic imaging, and gives insights on future directions. What the reader will gain Readers will learn about the various applications of photoacoustic imaging, as well as the various contrast agents that can be used to assist photoacoustic imaging. This review will highlight both pre-clinical and clinical uses for photoacoustic imaging, as well as discuss some of the challenges that must be addressed to move photoacoustic imaging into the clinical realm. Take home message Photoacoustic imaging offers unique advantages over existing imaging modalities. The imaging field is broad with many exciting applications for detecting and diagnosing diseased tissue or processes. Photoacoustics is also used in therapeutic applications to identify and characterize the pathology and then to monitor the treatment. Although the technology is still in its infancy, much work has been done in the pre-clinical arena, and photoacoustic imaging is fast approaching the clinical setting. PMID:21344060

  15. Spinal infections: clinical and imaging features.

    PubMed

    Arbelaez, Andres; Restrepo, Feliza; Castillo, Mauricio

    2014-10-01

    Spinal infections represent a group of rare conditions affecting vertebral bodies, intervertebral discs, paraspinal soft tissues, epidural space, meninges, and spinal cord. The causal factors, clinical presentations, and imaging features are a challenge because the difficulty to differentiate them from other conditions, such as degenerative and inflammatory disorders and spinal neoplasm. They require early recognition because delay diagnosis, imaging, and intervention may have devastating consequences especially in children and the elderly. This article reviews the most common spinal infections, their pathophysiologic, clinical manifestation, and their imaging findings.

  16. Population Pharmacokinetics of Intravenous Methotrexate in Patients with Hematological Malignancies: Utilization of Routine Clinical Monitoring Parameters.

    PubMed

    Nader, Ahmed; Zahran, Noran; Alshammaa, Aya; Altaweel, Heba; Kassem, Nancy; Wilby, Kyle John

    2017-04-01

    Clinical response to methotrexate in cancer is variable and depends on several factors including serum drug exposure. This study aimed to develop a population pharmacokinetic model describing methotrexate disposition in cancer patients using retrospective chart review data available from routine clinical practice. A retrospective review of medical records was conducted for cancer patients in Qatar. Relevant data (methotrexate dosing/concentrations from multiple occasions, patient history, and laboratory values) were extracted and analyzed using NONMEM VII ® . A population pharmacokinetic model was developed and used to estimate inter-individual and inter-occasion variability terms on methotrexate pharmacokinetic parameters, as well as patient factors affecting methotrexate pharmacokinetics. Methotrexate disposition was described by a two-compartment model with clearance (CL) of 15.7 L/h and central volume of distribution (V c ) of 79.2 L. Patient weight and hematocrit levels were significant covariates on methotrexate V c and CL, respectively. Methotrexate CL changed by 50 % with changes in hematocrit levels from 23 to 50 %. Inter-occasion variability in methotrexate CL was estimated for patients administered the drug on multiple occasions (48 and 31 % for 2nd and 3rd visits, respectively). Therapeutic drug monitoring data collected during routine clinical practice can provide a useful tool for understanding factors affecting methotrexate pharmacokinetics. Patient weight and hematocrit levels may play a clinically important role in determining methotrexate serum exposure and dosing requirements. Future prospective studies are needed to validate results of the developed model and evaluate its usefulness to predict methotrexate exposure and optimize dosing regimens.

  17. Developing the public health role of a front line clinical service: integrating stop smoking advice into routine podiatry services.

    PubMed

    Gray, Jackie; Eden, Gary; Williams, Maria

    2007-06-01

    Although smoking is a major public health problem, many clinicians do not routinely provide evidence-based health improvement advice to smokers to help them to quit. Plan, Do, Study, Act (PDSA) cycle methodology was used to design and implement a service development so that health improvement advice for smokers featured in all podiatry consultations provided by a Primary Care Trust in North East England. IT systems were developed to record the number and proportion of patients for whom smoking status was assessed, and the number and proportion of smokers who were given advice to quit and referred for specialist support. A questionnaire to staff explored their perceptions of the development on their clinics and consultations. During a 6-month period, smoking status was recorded for all 8831 (100%) patients attending podiatry clinics; 83% of smokers were given brief advice to quit; 7% of smokers were given help to access specialist stop smoking support services. Improvements were introduced within existing budgets and did not prolong clinics. It is straightforward and inexpensive to develop clinical services so that public health guidance is routinely implemented. More widespread implementation of similar service developments could lead to national improvements in public health.

  18. Atrial Fibrillation Management Strategies in Routine Clinical Practice: Insights from the International RealiseAF Survey

    PubMed Central

    Chiang, Chern-En; Naditch-Brûlé, Lisa; Brette, Sandrine; Silva-Cardoso, José; Gamra, Habib; Murin, Jan; Zharinov, Oleg J.; Steg, Philippe Gabriel

    2016-01-01

    Background Atrial fibrillation (AF) can be managed with rhythm- or rate-control strategies. There are few data from routine clinical practice on the frequency with which each strategy is used and their correlates in terms of patients’ clinical characteristics, AF control, and symptom burden. Methods RealiseAF was an international, cross-sectional, observational survey of 11,198 patients with AF. The aim of this analysis was to describe patient profiles and symptoms according to the AF management strategy used. A multivariate logistic regression identified factors associated with AF management strategy at the end of the visit. Results Among 10,497 eligible patients, 53.7% used a rate-control strategy, compared with 34.5% who used a rhythm-control strategy. In 11.8% of patients, no clear strategy was stated. The proportion of patients with AF-related symptoms (EHRA Class > = II) was 78.1% (n = 4396/5630) for those using a rate-control strategy vs. 67.8% for those using a rhythm-control strategy (p<0.001). Multivariate logistic regression analysis revealed that age <75 years or the paroxysmal or persistent form of AF favored the choice of a rhythm-control strategy. A change in strategy was infrequent, even in patients with European Heart Rhythm Association (EHRA) Class > = II. Conclusions In the RealiseAF routine clinical practice survey, rate control was more commonly used than rhythm control, and a change in strategy was uncommon, even in symptomatic patients. In almost 12% of patients, no clear strategy was stated. Physician awareness regarding optimal management strategies for AF may be improved. PMID:26800084

  19. A mixed methods approach to adapting health-related quality of life measures for use in routine oncology clinical practice.

    PubMed

    Harley, Clare; Takeuchi, Elena; Taylor, Sally; Keding, Ada; Absolom, Kate; Brown, Julia; Velikova, Galina

    2012-04-01

    The current study reviewed and adapted existing health-related quality of life (HRQoL) instruments for use in routine clinical practice delivering outpatient chemotherapy for colorectal, breast and gynaecological cancers. 564 (288 gynaecological, 208 breast and 68 colorectal) outpatient consultations of 141 patients were audio-recorded and analysed to identify discussed issues. Issues were ranked from most to least commonly discussed within each disease group. Existing HRQoL instruments were evaluated against these lists and best fitting items entered into cancer-specific item banks. Item banks were evaluated during semi-structured interviews by twenty-one oncologists (13 consultants and 8 specialist registrars), four clinical nurse specialists and thirty patients, from breast, gynaecological and colorectal cancer practices. Pilot questionnaires were completed by 448 (145 breast, 148 gynaecological and 155 colorectal) patients attending outpatient clinics. Item selection and scale reliability was explored using descriptive data and psychometric methods alongside qualitative patient and clinician ratings. Each questionnaire includes five physical and three psychosocial function scales each with good internal consistency reliability (α > 0.70) plus disease-specific individual-symptom items identified as useful in clinical practice. Three cancer-specific health-related quality of life measures were developed for use in routine clinical practice. Initial analyses suggest good clinical utility and acceptable psychometric properties for the new instruments.

  20. Routine Responses to Disruption of Routines

    ERIC Educational Resources Information Center

    Guha, Mahua

    2015-01-01

    "Organisational routines" is a widely studied research area. However, there is a dearth of research on disruption of routines. The few studies on disruption of routines discussed problem-solving activities that are carried out in response to disruption. In contrast, this study develops a theory of "solution routines" that are a…

  1. Arterial Destiffening in Previously Untreated Mild Hypertensives After 1 Year of Routine Clinical Management.

    PubMed

    Rodilla, Enrique; Millasseau, Sandrine; Costa, Jose Antonio; Pascual, Jose Maria

    2017-05-01

    Arterial stiffness, measured with pulse wave velocity (PWV), is now classified as a marker of target organ damage (TOD) alongside left ventricular hypertrophy and moderately increased albuminuria. Interventional studies on treated hypertensive patients have shown that PWV could be improved. Our aim was to assess changes in arterial stiffness after 1 year of routine clinical practice in never-treated hypertensive patients. We studied 356 never-treated patients with suspected hypertension. After standard clinical assessment during which presence of TOD was evaluated, hypertension diagnosis was confirmed in 231 subjects who subsequently received standard routine care. Both hypertensive and the 125 controls came back for a follow-up visit after 1 year. Hypertensive patients were slightly older (46 ± 12 vs. 50 ± 12 years, P < 0.001), with higher mean arterial pressure (MAP)-adjusted PWV compared to controls (8.6 ± 2.0 vs. 8.0 ± 1.7 m/s, P < 0.001) and 47% of them presented 1 or more TOD. After 1 year of treatment, MAP was similar in both groups (94.9 vs. 96.2 mm Hg; P = ns), but adjusted PWV remained significantly higher in the hypertensive patients (7.8 ± 1.4 vs. 8.3 ± 1.7 m/s, P = 0.004). The prevalence of elevated PWV was reduced from 20% to 12%. All antihypertensive drugs achieved the same blood pressure (BP) and PWV reduction with the exception of vasodilating beta-blockers which gave slightly better results probably due to heart rate reduction. BP reduction in newly diagnosed hypertensive patients improves arterial stiffness within a year of real-life clinical practice. Patients with the highest PWV and the largest reduction of BP "destiffened" the most whatever antihypertensive class was used. © American Journal of Hypertension, Ltd 2016. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  2. Clinical lead poisoning in England: an analysis of routine sources of data.

    PubMed

    Elliott, P; Arnold, R; Barltrop, D; Thornton, I; House, I M; Henry, J A

    1999-12-01

    To examine the occurrence of clinical lead poisoning in England based on routine sources of data. Three routine data sources were examined, over different periods according to availability of data: (a) mortality for England, 1981-96; (b) hospital episode statistics data for England, for the 3 years 1 April 1992-31 March 1995; (c) statutory returns to the Health and Safety Executive under the reporting of injuries, diseases, and dangerous occurrences regulations (RIDDOR), also for the period 1 April 1992-31 March 1995. Also, analyses of blood lead concentrations carried out by the Medical Toxicology Unit, Guy's and St Thomas' Hospital Trust in London during the period 1 January 1991-31 December 1997 were examined. The analyses were performed both for industrial screening purposes and in response to clinicians' requests where lead poisoning was suspected. This is one of several laboratories carrying out such analyses in the United Kingdom. One death, of a 2 year old girl, was coded to lead poisoning in England during 1981-96. Analysis of hospital episode statistics data identified 83 hospital cases (124 admissions) over 3 years with any mention of lead poisoning, excluding two with admissions dating from 1965 and 1969. For these 83 cases the median hospital stay per admission was 3 days (range 0-115 days). Five were coded as having received intravenous treatment. Further clinical details of these cases beyond what is routinely recorded on the hospital episode statistics database were not available, except for blood lead concentrations in cases also identified on the Medical Toxicology Unit database. Eighteen cases (22%) were below 5 years of age of whom 10 (56%) came from the most deprived quintile of electoral wards. There was evidence to suggest spatial clustering of cases (p = 0.02). Six occupational cases were reported under RIDDOR in England during the period of study, two of whom were identified on the hospital episode statistics database. One further

  3. Clinical and Pharmacogenetic Predictors of Circulating Atorvastatin and Rosuvastatin Concentration in Routine Clinical Care

    PubMed Central

    DeGorter, Marianne K.; Tirona, Rommel G.; Schwarz, Ute I.; Choi, Yun-Hee; Dresser, George K.; Suskin, Neville; Myers, Kathryn; Zou, GuangYong; Iwuchukwu, Otito; Wei, Wei-Qi; Wilke, Russell A.; Hegele, Robert A.; Kim, Richard B.

    2014-01-01

    Background A barrier to statin therapy is myopathy associated with elevated systemic drug exposure. Our objective was to examine the association between clinical and pharmacogenetic variables and statin concentrations in patients. Methods and Results In total, 299 patients taking atorvastatin or rosuvastatin were prospectively recruited at an outpatient referral center. The contribution of clinical variables and transporter gene polymorphisms to statin concentration was assessed using multiple linear regression. We observed 45-fold variation in statin concentration among patients taking the same dose. After adjustment for gender, age, body mass index, ethnicity, dose, and time from last dose, SLCO1B1 c.521T>C (p < 0.001) and ABCG2 c.421C>A (p < 0.01) were important to rosuvastatin concentration (adjusted R2 = 0.56 for the final model). Atorvastatin concentration was associated with SLCO1B1 c.388A>G (p < 0.01) and c.521T>C (p < 0.05), and 4β-hydroxycholesterol, a CYP3A activity marker (adjusted R2 = 0.47). A second cohort of 579 patients from primary and specialty care databases were retrospectively genotyped. In this cohort, genotypes associated with statin concentration were not differently distributed among dosing groups, implying providers had not yet optimized each patient's risk-benefit ratio. Nearly 50% of patients in routine practice taking the highest doses were predicted to have statin concentrations greater than the 90th percentile. Conclusions Interindividual variability in statin exposure in patients is associated with uptake and efflux transporter polymorphisms. An algorithm incorporating genomic and clinical variables to avoid high atorvastatin and rosuvastatin levels is described; further study will determine if this approach reduces incidence of statin-myopathy. PMID:23876492

  4. Quantitative Clinical Imaging Methods for Monitoring Intratumoral Evolution.

    PubMed

    Kim, Joo Yeun; Gatenby, Robert A

    2017-01-01

    images in landscape ecology and, with appropriate application of Darwinian first principles and sophisticated image analytic methods, can be used to estimate regional variations in the molecular properties of cancer cells.We have initially examined this technique in glioblastoma, a malignant brain neoplasm which is morphologically complex and notorious for a fast progression from diagnosis to recurrence and death, making a suitable subject of noninvasive, rapidly repeated assessment of intratumoral evolution. Quantitative imaging analysis of routine clinical MRIs from glioblastoma has identified macroscopic morphologic characteristics which correlate with proteogenomics and prognosis. The key to the accurate detection and forecasting of intratumoral evolution using quantitative imaging analysis is likely to be in the understanding of the synergistic interactions between observable intratumoral subregions and the resulting tumor behavior.

  5. Validation of the Italian version of the Clinical Outcomes in Routine Evaluation Outcome Measure (CORE-OM).

    PubMed

    Palmieri, Gaspare; Evans, Chris; Hansen, Vidje; Brancaleoni, Greta; Ferrari, Silvia; Porcelli, Piero; Reitano, Francesco; Rigatelli, Marco

    2009-01-01

    The Clinical Outcomes in Routine Evaluation--Outcome Measure (CORE-OM) was translated into Italian and tested in non-clinical (n = 263) and clinical (n = 647) samples. The translation showed good acceptability, internal consistency and convergent validity in both samples. There were large and statistically significant differences between clinical and non-clinical datasets on all scores. The reliable change criteria were similar to those for the UK referential data. Some of the clinically significant change criteria, particularly for the men, were moderately different from the UK cutting points. The Italian version of the CORE-OM showed respectable psychometric parameters. However, it seemed plausible that non-clinical and clinical distributions of self-report scores on psychopathology and functioning measures may differ by language and culture. *A good quality Italian translation of the CORE-OM, and hence the GP-CORE, CORE-10 and CORE-5 measures also, is now available for use by practitioners and anyone surveying or exploring general psychological state. The measures can be obtained from CORE-IMS or yourself and practitioners are encouraged to share anonymised data so that good clinical and non-clinical referential databases can be established for Italy.

  6. Clinical Utility of Quantitative Imaging

    PubMed Central

    Rosenkrantz, Andrew B; Mendiratta-Lala, Mishal; Bartholmai, Brian J.; Ganeshan, Dhakshinamoorthy; Abramson, Richard G.; Burton, Kirsteen R.; Yu, John-Paul J.; Scalzetti, Ernest M.; Yankeelov, Thomas E.; Subramaniam, Rathan M.; Lenchik, Leon

    2014-01-01

    Quantitative imaging (QI) is increasingly applied in modern radiology practice, assisting in the clinical assessment of many patients and providing a source of biomarkers for a spectrum of diseases. QI is commonly used to inform patient diagnosis or prognosis, determine the choice of therapy, or monitor therapy response. Because most radiologists will likely implement some QI tools to meet the patient care needs of their referring clinicians, it is important for all radiologists to become familiar with the strengths and limitations of QI. The Association of University Radiologists Radiology Research Alliance Quantitative Imaging Task Force has explored the clinical application of QI and summarizes its work in this review. We provide an overview of the clinical use of QI by discussing QI tools that are currently employed in clinical practice, clinical applications of these tools, approaches to reporting of QI, and challenges to implementing QI. It is hoped that these insights will help radiologists recognize the tangible benefits of QI to their patients, their referring clinicians, and their own radiology practice. PMID:25442800

  7. Ultrasound transducer selection in clinical imaging practice.

    PubMed

    Szabo, Thomas L; Lewin, Peter A

    2013-04-01

    Many types of medical ultrasound transducers are used in clinical practice. They operate at different center frequencies, have different physical dimensions, footprints, and shapes, and provide different image formats. However, little information is available about which transducers are most appropriate for a given application, and the purpose of this article is to address this deficiency. Specifically, the relationship between the transducer, imaging format, and clinical applications is discussed, and systematic selection criteria that allow matching of transducers to specific clinical needs are presented. These criteria include access to and coverage of the region of interest, maximum scan depth, and coverage of essential diagnostic modes required to optimize a patient's diagnosis. Three comprehensive figures organize and summarize the imaging planes, scanning modes, and types of diagnostic transducers to facilitate their selection in clinical diagnosis.

  8. Semiautomated Workflow for Clinically Streamlined Glioma Parametric Response Mapping

    PubMed Central

    Keith, Lauren; Ross, Brian D.; Galbán, Craig J.; Luker, Gary D.; Galbán, Stefanie; Zhao, Binsheng; Guo, Xiaotao; Chenevert, Thomas L.; Hoff, Benjamin A.

    2017-01-01

    Management of glioblastoma multiforme remains a challenging problem despite recent advances in targeted therapies. Timely assessment of therapeutic agents is hindered by the lack of standard quantitative imaging protocols for determining targeted response. Clinical response assessment for brain tumors is determined by volumetric changes assessed at 10 weeks post-treatment initiation. Further, current clinical criteria fail to use advanced quantitative imaging approaches, such as diffusion and perfusion magnetic resonance imaging. Development of the parametric response mapping (PRM) applied to diffusion-weighted magnetic resonance imaging has provided a sensitive and early biomarker of successful cytotoxic therapy in brain tumors while maintaining a spatial context within the tumor. Although PRM provides an earlier readout than volumetry and sometimes greater sensitivity compared with traditional whole-tumor diffusion statistics, it is not routinely used for patient management; an automated and standardized software for performing the analysis and for the generation of a clinical report document is required for this. We present a semiautomated and seamless workflow for image coregistration, segmentation, and PRM classification of glioblastoma multiforme diffusion-weighted magnetic resonance imaging scans. The software solution can be integrated using local hardware or performed remotely in the cloud while providing connectivity to existing picture archive and communication systems. This is an important step toward implementing PRM analysis of solid tumors in routine clinical practice. PMID:28286871

  9. Breast Volume Measurement by Recycling the Data Obtained From 2 Routine Modalities, Mammography and Magnetic Resonance Imaging.

    PubMed

    Itsukage, Shizu; Sowa, Yoshihiro; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki

    2017-01-01

    Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes' principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging.

  10. Breast Volume Measurement by Recycling the Data Obtained From 2 Routine Modalities, Mammography and Magnetic Resonance Imaging

    PubMed Central

    Itsukage, Shizu; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki

    2017-01-01

    Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes’ principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging. PMID:29308107

  11. Narrative meaning making is associated with sudden gains in psychotherapy clients' mental health under routine clinical conditions.

    PubMed

    Adler, Jonathan M; Harmeling, Luke H; Walder-Biesanz, Ilana

    2013-10-01

    The present study had two aims: (a) to replicate previous findings regarding the characteristics of sudden gains (SGs) in psychotherapy under routine clinical conditions and (b) to examine whether clients' narrative meaning-making processes were associated with SGs in mental health. 54 psychotherapy clients completed the Systemic Therapy Inventory of Change (Pinsof et al., 2009) and wrote private narratives prior to beginning treatment and between every session for 12 assessment points over the course of psychotherapy for a variety of presenting problems. Clients' narratives were coded using existing systems (Adler, 2012; A. M. Hayes, Feldman, & Goldfried, 2006) to assess their content in eight themes: processing, avoidance, coherence, positive self, negative self, agency, hope, and hopelessness. The prevalence, magnitude, and timing of SGs in mental health observed in the present study were similar to those observed in prior research. Two narrative meaning-making processes-processing and coherence-were significantly associated with SGs in mental health. The present study significantly extends prior research on SGs, replicating the characteristics of these gains in routine clinical conditions with a measure of general functioning and identifying two narrative meaning-making processes that are associated with SGs in mental health.

  12. Lissencephaly: expanded imaging and clinical classification

    PubMed Central

    Di Donato, Nataliya; Chiari, Sara; Mirzaa, Ghayda M.; Aldinger, Kimberly; Parrini, Elena; Olds, Carissa; Barkovich, A. James; Guerrini, Renzo; Dobyns, William B.

    2017-01-01

    Lissencephaly (“smooth brain”, LIS) is a malformation of cortical development associated with deficient neuronal migration and abnormal formation of cerebral convolutions or gyri. The LIS spectrum includes agyria, pachygyria, and subcortical band heterotopia. Our first classification of LIS and subcortical band heterotopia (SBH) was developed to distinguish between the first two genetic causes of LIS – LIS1 (PAFAH1B1) and DCX. However, progress in molecular genetics has led to identification of 19 LIS-associated genes, leaving the existing classification system insufficient to distinguish the increasingly diverse patterns of LIS. To address this challenge, we reviewed clinical, imaging and molecular data on 188 patients with LIS-SBH ascertained during the last five years, and reviewed selected archival data on another ~1,400 patients. Using these data plus published reports, we constructed a new imaging based classification system with 21 recognizable patterns that reliably predict the most likely causative genes. These patterns do not correlate consistently with the clinical outcome, leading us to also develop a new scale useful for predicting clinical severity and outcome. Taken together, our work provides new tools that should prove useful for clinical management and genetic counselling of patients with LIS-SBH (imaging and severity based classifications), and guidance for prioritizing and interpreting genetic testing results (imaging based classification). PMID:28440899

  13. A new generation of cancer genome diagnostics for routine clinical use: overcoming the roadblocks to personalized cancer medicine.

    PubMed

    Heuckmann, J M; Thomas, R K

    2015-09-01

    The identification of 'druggable' kinase gene alterations has revolutionized cancer treatment in the last decade by providing new and successfully targetable drug targets. Thus, genotyping tumors for matching the right patients with the right drugs have become a clinical routine. Today, advances in sequencing technology and computational genome analyses enable the discovery of a constantly growing number of genome alterations relevant for clinical decision making. As a consequence, several technological approaches have emerged in order to deal with these rapidly increasing demands for clinical cancer genome analyses. Here, we describe challenges on the path to the broad introduction of diagnostic cancer genome analyses and the technologies that can be applied to overcome them. We define three generations of molecular diagnostics that are in clinical use. The latest generation of these approaches involves deep and thus, highly sensitive sequencing of all therapeutically relevant types of genome alterations-mutations, copy number alterations and rearrangements/fusions-in a single assay. Such approaches therefore have substantial advantages (less time and less tissue required) over PCR-based methods that typically have to be combined with fluorescence in situ hybridization for detection of gene amplifications and fusions. Since these new technologies work reliably on routine diagnostic formalin-fixed, paraffin-embedded specimens, they can help expedite the broad introduction of personalized cancer therapy into the clinic by providing comprehensive, sensitive and accurate cancer genome diagnoses in 'real-time'. © The Author 2015. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  14. Utility of routine postoperative visit after appendectomy and cholecystectomy with evaluation of mobile technology access in an urban safety net population.

    PubMed

    Chen, Diane W; Davis, Rachel W; Balentine, Courtney J; Scott, Aaron R; Gao, Yue; Tapia, Nicole M; Berger, David H; Suliburk, James W

    2014-08-01

    The value of routine postoperative visits after general surgery remains unclear. The objective of this study was to evaluate the utility of routine postoperative visits after appendectomy and cholecystectomy and to determine access to mobile technology as an alternative platform for follow-up. Retrospective review of 219 appendectomies and 200 cholecystectomies performed at a safety net hospital. One patient underwent both surgeries. Patient demographics, duration of clinic visit, and need for additional imaging, tests or readmissions were recorded. Access to mobile technology was surveyed by a validated questionnaire. Of 418 patients, 84% percent completed a postoperative visit. At follow-up, 58 patients (14%) required 70 interventions, including staple removal (16, 23%), suture removal (4, 6%), drain removal (8, 11%), additional follow-up (20, 28%), medication action (16, 21%), additional imaging (3, 4%), and readmission (1, 1%). Occupational paperwork (62) and nonsurgical clinic referrals (28) were also performed. Average check-in to check-out time was 100 ± 54 min per patient. One intervention was performed for every 7.8 h of time in the clinic. Additionally, 88% of the surveyed population reported access to cell phone technology, and 69% of patients <40 y had smartphone access. Routine in-person follow-up after surgery consumes significant time and resources for patients and healthcare systems but has little impact on patient care. Most of the work done in the clinic is administrative and could be completed using mobile technology, which is pervasive in our population. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Objections to routine clinical outcomes measurement in mental health services: any evidence so far?

    PubMed

    MacDonald, Alastair J D; Trauer, Tom

    2010-12-01

    Routine clinical outcomes measurement (RCOM) is gaining importance in mental health services. To examine whether criticisms published in advance of the development of RCOM have been borne out by data now available from such a programme. This was an observational study of routine ratings using HoNOS65+ at inception/admission and again at discharge in an old age psychiatry service from 1997 to 2008. Testable hypotheses were generated from each criticism amenable to empirical examination. Inter-rater reliability estimates were applied to observed differences between scores between community and ward patients using resampling. Five thousand one hundred eighty community inceptions and 862 admissions had HoNOS65+ ratings at referral/admission and discharge. We could find no evidence of gaming (artificially worse scores at inception and better at discharge), selection, attrition or detection bias, and ratings were consistent with diagnosis and level of service. Anticipated low levels of inter-rater reliability did not vitiate differences between levels of service. Although only hypotheses testable from within RCOM data were examined, and only 46% of eligible episodes had complete outcomes data, no evidence of the alleged biases were found. RCOM seems valid and practical in mental health services.

  16. Comparison between low (3:1) and high (6:1) pitch for routine abdominal/pelvic imaging with multislice computed tomography.

    PubMed

    Sahani, Dushyant; Saini, Sanjay; D'Souza, Roy V; O'Neill, Mary Jane; Prasad, Srinivasa R; Kalra, Mannudeep K; Halpern, Elkan F; Mueller, Peter

    2003-01-01

    The purpose of this study was to compare the performance of low helical pitch acquisition (3:1) and high helical pitch acquisition (6:1) for routine abdominal/pelvic imaging with multislice computed tomography (CT). Three hundred eighty-four patients referred for abdominal/pelvic CT were examined in a breath-hold on a multislice CT scanner (LightSpeed QX/I; General Electric Medical Systems, Milwaukee, WI). Patients were randomized and scanned with pitch of 3:1 or 6:1 using a constant 140 peak kV and 280-300 mA. Images were reconstructed at a 3.75-mm slice thickness. Direct comparison between the two pitches was possible in a subset of 40 patients who had a follow-up scan performed with the second pitch used in each patient. A comparison was also performed between standard dose CT using a pitch of 6:1 and 20% reduced radiation dose CT using a pitch of 3:1. Two readers performed a blind evaluation using a three-point scale for image quality, anatomic details, and motion artifacts. Statistical analysis was performed using a rank sum test and the Wilcoxon signed rank test. Overall image quality mean scores were 2.5 and 2.3 for a pitch of 3:1 and a pitch of 6:1, respectively (P = 0.134). Likewise, mean anatomic detail and motion artifact scores were 2.5 and 2.6 for a 3:1 pitch and 2.3 and 2.5 for a 6:1 pitch, respectively (P > 0.05). In patients with a direct comparison of the two pitches (with the standard radiation dose as well as with a 20% reduction in milliamperes), no statistically significant difference in the performance of the two pitches was observed (P > 0.05). Image quality with a high pitch (6:1) is acceptable for routine abdominal/pelvic CT.

  17. The significance of routines in nursing practice.

    PubMed

    Rytterström, Patrik; Unosson, Mitra; Arman, Maria

    2011-12-01

    The aim of this study was to illuminate the significance of routines in nursing practice. Clinical nursing is performed under the guidance of routines to varying degrees. In the nursing literature, routine is described as having both negative and positive aspects, but use of the term is inconsistent, and empirical evidence is sparse. In the research on organisational routines, a distinction is made between routine as a rule and routine as action. A qualitative design using a phenomenological-hermeneutic approach. Data collection from three focus groups focused on nurses' experience of routines. Seventeen individual interviews from a previous study focusing on caring culture were also analysed in a secondary qualitative analysis. All participants were employed as 'qualified nursing pool' nurses. Routines are experienced as pragmatic, obstructive and meaningful. The aim of the pragmatic routine was to ensure that daily working life works; this routine is practised more on the basis of rational arguments and obvious intentions. The obstructive routine had negative consequences for nursing practice and was described as nursing losing its humanity and violating the patient's integrity. The meaningful routine involved becoming one with the routine and for the nurses, it felt right and meaningful to adapt to it. Routines become meaningful when the individual action is in harmony with the cultural pattern on which the nursing work is based. Instead of letting contemporary practice passively become routine, routines can be assessed and developed using research and theoretical underpinnings as a starting point for nursing practice. Leaders have a special responsibility to develop and support meaningful routines. One approach could be to let wards examine their routines from a patient perspective on the basis of the themes of pragmatic, meaningful and obstructive routine. © 2010 Blackwell Publishing Ltd.

  18. Time-lapse microscopy and image analysis in basic and clinical embryo development research.

    PubMed

    Wong, C; Chen, A A; Behr, B; Shen, S

    2013-02-01

    Mammalian preimplantation embryo development is a complex process in which the exact timing and sequence of events are as essential as the accurate execution of the events themselves. Time-lapse microscopy (TLM) is an ideal tool to study this process since the ability to capture images over time provides a combination of morphological, dynamic and quantitative information about developmental events. Here, we systematically review the application of TLM in basic and clinical embryo research. We identified all relevant preimplantation embryo TLM studies published in English up to May 2012 using PubMed and Google Scholar. We then analysed the technical challenges involved in embryo TLM studies and how these challenges may be overcome with technological innovations. Finally, we reviewed the different types of TLM embryo studies, with a special focus on how TLM can benefit clinical assisted reproduction. Although new parameters predictive of embryo development potential may be discovered and used clinically to potentially increase the success rate of IVF, adopting TLM to routine clinical practice will require innovations in both optics and image analysis. Combined with such innovations, TLM may provide embryologists and clinicians with an important tool for making critical decisions in assisted reproduction. In this review, we perform a literature search of all published early embryo development studies that used time-lapse microscopy (TLM). From the literature, we discuss the benefits of TLM over traditional time-point analysis, as well as the technical difficulties and solutions involved in implementing TLM for embryo studies. We further discuss research that has successfully derived non-invasive markers that may increase the success rate of assisted reproductive technologies, primarily IVF. Most notably, we extend our discussion to highlight important considerations for the practical use of TLM in research and clinical settings. Copyright © 2012 Reproductive

  19. Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

    PubMed

    McCollough, Cynthia H; Chen, Guang Hong; Kalender, Willi; Leng, Shuai; Samei, Ehsan; Taguchi, Katsuyuki; Wang, Ge; Yu, Lifeng; Pettigrew, Roderic I

    2012-08-01

    This Special Report presents the consensus of the Summit on Management of Radiation Dose in Computed Tomography (CT) (held in February 2011), which brought together participants from academia, clinical practice, industry, and regulatory and funding agencies to identify the steps required to reduce the effective dose from routine CT examinations to less than 1 mSv. The most promising technologies and methods discussed at the summit include innovations and developments in x-ray sources; detectors; and image reconstruction, noise reduction, and postprocessing algorithms. Access to raw projection data and standard data sets for algorithm validation and optimization is a clear need, as is the need for new, clinically relevant metrics of image quality and diagnostic performance. Current commercially available techniques such as automatic exposure control, optimization of tube potential, beam-shaping filters, and dynamic z-axis collimators are important, and education to successfully implement these methods routinely is critically needed. Other methods that are just becoming widely available, such as iterative reconstruction, noise reduction, and postprocessing algorithms, will also have an important role. Together, these existing techniques can reduce dose by a factor of two to four. Technical advances that show considerable promise for additional dose reduction but are several years or more from commercial availability include compressed sensing, volume of interest and interior tomography techniques, and photon-counting detectors. This report offers a strategic roadmap for the CT user and research and manufacturer communities toward routinely achieving effective doses of less than 1 mSv, which is well below the average annual dose from naturally occurring sources of radiation.

  20. Current status of the joint Mayo Clinic-IBM PACS project

    NASA Astrophysics Data System (ADS)

    Hangiandreou, Nicholas J.; Williamson, Byrn, Jr.; Gehring, Dale G.; Persons, Kenneth R.; Reardon, Frank J.; Salutz, James R.; Felmlee, Joel P.; Loewen, M. D.; Forbes, Glenn S.

    1994-05-01

    A multi-phase collaboration between Mayo Clinic and IBM-Rochester was undertaken, with the goal of developing a picture archiving and communication system for routine clinical use in the Radiology Department. The initial phase of this project (phase 0) was started in 1988. The current system has been fully integrated into the clinical practice and, to date, over 6.5 million images from 16 imaging modalities have been archived. Phase 3 of this project has recently concluded.

  1. A review of biomechanically informed breast image registration

    NASA Astrophysics Data System (ADS)

    Hipwell, John H.; Vavourakis, Vasileios; Han, Lianghao; Mertzanidou, Thomy; Eiben, Björn; Hawkes, David J.

    2016-01-01

    Breast radiology encompasses the full range of imaging modalities from routine imaging via x-ray mammography, magnetic resonance imaging and ultrasound (both two- and three-dimensional), to more recent technologies such as digital breast tomosynthesis, and dedicated breast imaging systems for positron emission mammography and ultrasound tomography. In addition new and experimental modalities, such as Photoacoustics, Near Infrared Spectroscopy and Electrical Impedance Tomography etc, are emerging. The breast is a highly deformable structure however, and this greatly complicates visual comparison of imaging modalities for the purposes of breast screening, cancer diagnosis (including image guided biopsy), tumour staging, treatment monitoring, surgical planning and simulation of the effects of surgery and wound healing etc. Due primarily to the challenges posed by these gross, non-rigid deformations, development of automated methods which enable registration, and hence fusion, of information within and across breast imaging modalities, and between the images and the physical space of the breast during interventions, remains an active research field which has yet to translate suitable methods into clinical practice. This review describes current research in the field of breast biomechanical modelling and identifies relevant publications where the resulting models have been incorporated into breast image registration and simulation algorithms. Despite these developments there remain a number of issues that limit clinical application of biomechanical modelling. These include the accuracy of constitutive modelling, implementation of representative boundary conditions, failure to meet clinically acceptable levels of computational cost, challenges associated with automating patient-specific model generation (i.e. robust image segmentation and mesh generation) and the complexity of applying biomechanical modelling methods in routine clinical practice.

  2. Assessment of three frequently used blood glucose monitoring devices in clinical routine.

    PubMed

    Zueger, Thomas; Schuler, Vanessa; Stettler, Christoph; Diem, Peter; Christ, Emanuel R

    2012-07-12

    Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aimed to evaluate three frequently used blood glucose meters in daily clinical practice. Capillary blood glucose was measured simultaneous using the following glucose meters: Contour® (Bayer Diabetes Care, Zürich, Switzerland), Accu-Chek® aviva (Roche Diagnostics, Rotkreuz, Switzerland), Free-Style® lite (Abbott Diabetes Care, Baar, Switzerland). The reference method consisted of the HemoCue® Glucose 201+ System (HemoCue® AB, Ängelholm, Sweden) with plasma conversion. The devices were assessed by comparison of the Mean Absolute Relative Differences (MARD), the Clarke Error Grid Analysis (EGA) and the compliance with the International Organization of Standardization criteria (ISO 15197:2003). Capillary blood samples were obtained from 150 patients. MARD was 10.1 ± 0.65%, 7.0 ± 0.62% and 7.8 ± 0.48% for Contour®, Accu-Chek® and Free-Style®, respectively. EGA showed 99.3% (Contour®), 98.7% (Accu-Chek®) and 100% (Free-Style®) of all measurements in zone A and B (clinically acceptable). The ISO criteria were fulfilled by Accu-Chek® (95.3%) and Free-Style® (96%), but not by Contour® (92%). In the present study the three glucose meters provided good agreement with the reference and reliable results in daily clinical routine. Overall, the Free-Style® and Accu-Chek® device slightly outperformed the Contour® device.

  3. Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application.

    PubMed

    Karakatsanis, Nicolas A; Lodge, Martin A; Tahari, Abdel K; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-10-21

    Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single-bed-coverage limiting the axial field-of-view to ~15-20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole-body PET acquisition protocol of ~45 min total length is presented, composed of (i) an initial 6 min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (six passes × seven bed positions, each scanned for 45 s). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of ten different clinically

  4. Dynamic whole body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application

    PubMed Central

    Karakatsanis, Nicolas A.; Lodge, Martin A.; Tahari, Abdel K.; Zhou, Y.; Wahl, Richard L.; Rahmim, Arman

    2013-01-01

    Static whole body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single bed-coverage limiting the axial field-of-view to ~15–20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole body PET acquisition protocol of ~45min total length is presented, composed of (i) an initial 6-min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (6 passes x 7 bed positions, each scanned for 45sec). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares (OLS) Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of 10 different clinically

  5. Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application

    NASA Astrophysics Data System (ADS)

    Karakatsanis, Nicolas A.; Lodge, Martin A.; Tahari, Abdel K.; Zhou, Y.; Wahl, Richard L.; Rahmim, Arman

    2013-10-01

    Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single-bed-coverage limiting the axial field-of-view to ˜15-20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole-body PET acquisition protocol of ˜45 min total length is presented, composed of (i) an initial 6 min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (six passes × seven bed positions, each scanned for 45 s). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of ten different clinically

  6. Programmable Real-time Clinical Photoacoustic and Ultrasound Imaging System

    PubMed Central

    Kim, Jeesu; Park, Sara; Jung, Yuhan; Chang, Sunyeob; Park, Jinyong; Zhang, Yumiao; Lovell, Jonathan F.; Kim, Chulhong

    2016-01-01

    Photoacoustic imaging has attracted interest for its capacity to capture functional spectral information with high spatial and temporal resolution in biological tissues. Several photoacoustic imaging systems have been commercialized recently, but they are variously limited by non-clinically relevant designs, immobility, single anatomical utility (e.g., breast only), or non-programmable interfaces. Here, we present a real-time clinical photoacoustic and ultrasound imaging system which consists of an FDA-approved clinical ultrasound system integrated with a portable laser. The system is completely programmable, has an intuitive user interface, and can be adapted for different applications by switching handheld imaging probes with various transducer types. The customizable photoacoustic and ultrasound imaging system is intended to meet the diverse needs of medical researchers performing both clinical and preclinical photoacoustic studies. PMID:27731357

  7. Programmable Real-time Clinical Photoacoustic and Ultrasound Imaging System.

    PubMed

    Kim, Jeesu; Park, Sara; Jung, Yuhan; Chang, Sunyeob; Park, Jinyong; Zhang, Yumiao; Lovell, Jonathan F; Kim, Chulhong

    2016-10-12

    Photoacoustic imaging has attracted interest for its capacity to capture functional spectral information with high spatial and temporal resolution in biological tissues. Several photoacoustic imaging systems have been commercialized recently, but they are variously limited by non-clinically relevant designs, immobility, single anatomical utility (e.g., breast only), or non-programmable interfaces. Here, we present a real-time clinical photoacoustic and ultrasound imaging system which consists of an FDA-approved clinical ultrasound system integrated with a portable laser. The system is completely programmable, has an intuitive user interface, and can be adapted for different applications by switching handheld imaging probes with various transducer types. The customizable photoacoustic and ultrasound imaging system is intended to meet the diverse needs of medical researchers performing both clinical and preclinical photoacoustic studies.

  8. Multimodal tissue perfusion imaging using multi-spectral and thermographic imaging systems applied on clinical data

    NASA Astrophysics Data System (ADS)

    Klaessens, John H. G. M.; Nelisse, Martin; Verdaasdonk, Rudolf M.; Noordmans, Herke Jan

    2013-03-01

    Clinical interventions can cause changes in tissue perfusion, oxygenation or temperature. Real-time imaging of these phenomena could be useful for surgical strategy or understanding of physiological regulation mechanisms. Two noncontact imaging techniques were applied for imaging of large tissue areas: LED based multispectral imaging (MSI, 17 different wavelengths 370 nm-880 nm) and thermal imaging (7.5 to 13.5 μm). Oxygenation concentration changes were calculated using different analyzing methods. The advantages of these methods are presented for stationary and dynamic applications. Concentration calculations of chromophores in tissue require right choices of wavelengths The effects of different wavelength choices for hemoglobin concentration calculations were studied in laboratory conditions and consequently applied in clinical studies. Corrections for interferences during the clinical registrations (ambient light fluctuations, tissue movements) were performed. The wavelength dependency of the algorithms were studied and wavelength sets with the best results will be presented. The multispectral and thermal imaging systems were applied during clinical intervention studies: reperfusion of tissue flap transplantation (ENT), effectiveness of local anesthetic block and during open brain surgery in patients with epileptic seizures. The LED multispectral imaging system successfully imaged the perfusion and oxygenation changes during clinical interventions. The thermal images show local heat distributions over tissue areas as a result of changes in tissue perfusion. Multispectral imaging and thermal imaging provide complementary information and are promising techniques for real-time diagnostics of physiological processes in medicine.

  9. [Microdose clinical trial--impact of PET molecular imaging].

    PubMed

    Yano, Tsuneo; Watanabe, Yasuyoshi

    2010-10-01

    Microdose (MD) clinical trial and exploratory IND study including sub-therapeutic dose and therapeutic dose which are higher than microdoses are expected to bring about innovations in drug development. The outlines of guidances for microdose clinical trial and ICH-M3 (R2) issued by the MHLW in June, 2008, and February, 2010, are first explained, respectively, and some examples of their application to clinical developments of therapeutic drugs in the infection and cancer fields are introduced. Especially, thanks to the progress of molecular imaging research, a new field of drug development is explored by using imaging biomarkers for efficacy or safety evaluation which visualize biomarkers by PET imaging agents. Finally, the roadmap for drug development in infection and cancer fields utilizing PET molecular imaging is discussed.

  10. [How to Interpret and Use Routine Laboratory Data--Our Methods to Interpret Routine Laboratory Data--Chairmen's Introductory Remarks].

    PubMed

    Honda, Takayuki; Tozuka, Minoru

    2015-09-01

    In the reversed clinicopathological conference (R-CPC), three specialists in laboratory medicine interpreted routine laboratory data independently in order to understand the detailed state of a patient. R-CPC is an educational method to use laboratory data appropriately, and it is also important to select differential diagnoses in a process of clinical reasoning in addition to the present illness and physical examination. Routine laboratory tests can be performed repeatedly at a relatively low cost, and their time-series analysis can be performed. Interpretation of routine laboratory data is almost the same as taking physical findings. General findings are initially checked and then the state of each organ is examined. Although routine laboratory tests cost little, we can gain much more information from them about the patient than physical examinations.

  11. Assessing barriers to adherence in routine clinical care for pediatric kidney transplant patients.

    PubMed

    Varnell, Charles D; Rich, Kristin L; Nichols, Melissa; Dahale, Devesh; Goebel, Jens W; Pai, Ahna L H; Hooper, David K; Modi, Avani C

    2017-11-01

    Patient-identified barriers to immunosuppressive medications are associated with poor adherence and negative clinical outcomes in transplant patients. Assessment of adherence barriers is not part of routine post-transplant care, and studies regarding implementing such a process in a reliable way are lacking. Using the Model for Improvement and PDSA cycles, we implemented a system to identify adherence barriers, including patient-centered design of a barriers assessment tool, identification of eligible patients, clear roles for clinic staff, and creating a culture of non-judgmental discussion around adherence. We performed time-series analysis of our process measure. Secondary analyses examined the endorsement and concordance of adherence barriers between patient-caregiver dyads. After three methods of testing, the most reliable delivery system was an EHR-integrated tablet that alerted staff of patient eligibility for assessment. Barriers were endorsed by 35% of caregivers (n=85) and 43% of patients (n=60). The most frequently patient-endorsed barriers were forgetting, poor taste, and side effects. Caregivers endorsed forgetting and side effects. Concordance between patient-caregiver dyads was fair (k=0.299). Standardized adherence barriers assessment is feasible in the clinical care of pediatric kidney transplant patients. Features necessary for success included automation, redundant systems with designated staff to identify and mitigate failures, aligned reporting structures, and reliable measurement approaches. Future studies will examine whether barriers predict clinical outcomes (eg, organ rejection, graft loss). © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. SPECT-CT in routine clinical practice: increase in patient radiation dose compared with SPECT alone.

    PubMed

    Sharma, Punit; Sharma, Shekhar; Ballal, Sanjana; Bal, Chandrasekhar; Malhotra, Arun; Kumar, Rakesh

    2012-09-01

    To assess the patient radiation dose during routine clinical single-photon emission computed tomography-computed tomography (SPECT-CT) and measure the increase as compared with SPECT alone. Data pertaining to 357 consecutive patients who had undergone radioisotope imaging along with SPECT-CT of a selected volume were retrospectively evaluated. Dose of the injected radiopharmaceutical (MBq) was noted, and the effective dose (mSv) was calculated as per International Commission on Radiological Protection (ICRP) guidelines. The volume-weighted computed tomography dose index (CTDIvol) and dose length product of the CT were also assessed using standard phantoms. The effective dose (mSv) due to CT was calculated as the product of dose length product and a conversion factor depending on the region of investigation, using ICRP guidelines. The dose due to CT was compared among different investigations. The increase in effective dose was calculated as CT dose expressed as a percentage of radiopharmaceutical dose. The per-patient CT effective dose for different studies varied between 0.06 and 11.9 mSv. The mean CT effective dose was lowest for 99mTc-ethylene cysteine dimer brain SPECT-CT (0.9 ± 0.7) and highest for 99mTc-methylene diphosphonate bone SPECT-CT (4.2 ± 2.8). The increase in radiation dose (SPECT-CT vs. SPECT) varied widely (2.3-666.4% for 99mTc-tracers and 0.02-96.2% for 131I-tracers). However, the effective dose of CT in SPECT-CT was less than the values reported for conventional CT examinations of the same regions. Addition of CT to nuclear medicine imaging in the form of SPECT-CT increases the radiation dose to the patient, with the effective dose due to CT exceeding the effective dose of RP in many instances. Hence, appropriate utilization and optimization of the protocols of SPECT-CT is needed to maximize benefit to patients.

  13. Clinical study of imaging skin cancer margins using polarized light imaging

    NASA Astrophysics Data System (ADS)

    Samatham, Ravikant; Lee, Ken; Jacques, Steven L.

    2012-02-01

    Skin cancer is most commons type of cancer in United States that occur on sun-exposed cosmetically sensitive areas like face, neck, and forearms. Surgical excision of skin cancer is challenging as more than one-third the actual margins extend beyond the clinically determined margins. Polarized light camera (polCAM) provides images of the superficial layers of the tissue with enhanced contrast which was used to image skin cancer margins. In a NIH-funded pilot study polCAM was used to image skin cancer in patients undergoing Mohs micrographic surgery for skin cancer. Polarized light imaging utilizes the polarization properties of light to create an image of a lesion comprised only of light scattering from the superficial layers of the skin which yields a characteristic "fabric pattern" of the putative lesion and the surrounding normal tissue. In several case studies conducted with a system developed for the clinic, we have found that skin cancer disrupts this fabric pattern, allowing the doctor a new means of identifying the margins of the lesion. Data is acquired before the patient underwent surgery. The clinically determined skin cancer margins were compared with margins determined by examination of the polCAM images. The true margins were provided by the dermatophathologist on examination of the frozen sections. Our initial data suggests that the contrast due to polarization changes associated with cancerous lesions can elucidate margins that were not recognized by the surgeon under normal conditions but were later confirmed by the pathologist.

  14. Imaging mass spectrometry statistical analysis.

    PubMed

    Jones, Emrys A; Deininger, Sören-Oliver; Hogendoorn, Pancras C W; Deelder, André M; McDonnell, Liam A

    2012-08-30

    Imaging mass spectrometry is increasingly used to identify new candidate biomarkers. This clinical application of imaging mass spectrometry is highly multidisciplinary: expertise in mass spectrometry is necessary to acquire high quality data, histology is required to accurately label the origin of each pixel's mass spectrum, disease biology is necessary to understand the potential meaning of the imaging mass spectrometry results, and statistics to assess the confidence of any findings. Imaging mass spectrometry data analysis is further complicated because of the unique nature of the data (within the mass spectrometry field); several of the assumptions implicit in the analysis of LC-MS/profiling datasets are not applicable to imaging. The very large size of imaging datasets and the reporting of many data analysis routines, combined with inadequate training and accessible reviews, have exacerbated this problem. In this paper we provide an accessible review of the nature of imaging data and the different strategies by which the data may be analyzed. Particular attention is paid to the assumptions of the data analysis routines to ensure that the reader is apprised of their correct usage in imaging mass spectrometry research. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Imaging of femoroacetabular impingement-current concepts

    PubMed Central

    Albers, Christoph E.; Wambeek, Nicholas; Hanke, Markus S.; Schmaranzer, Florian; Prosser, Gareth H.; Yates, Piers J.

    2016-01-01

    Following the recognition of femoroacetabular impingement (FAI) as a clinical entity, diagnostic tools have continuously evolved. While the diagnosis of FAI is primarily made based on the patients’ history and clinical examination, imaging of FAI is indispensable. Routine diagnostic work-up consists of a set of plain radiographs, magnetic resonance imaging (MRI) and MR-arthrography. Recent advances in MRI technology include biochemically sensitive sequences bearing the potential to detect degenerative changes of the hip joint at an early stage prior to their appearance on conventional imaging modalities. Computed tomography may serve as an adjunct. Advantages of CT include superior bone to soft tissue contrast, making CT applicable for image-guiding software tools that allow evaluation of the underlying dynamic mechanisms causing FAI. This article provides a summary of current concepts of imaging in FAI and a review of the literature on recent advances, and their application to clinical practice. PMID:29632685

  16. Pulmonary aspiration of gastric contents during routine endoscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    La France, N.D.; Cole, P.; Wolfe, E.

    Radioactive tracer studies are a sensitive means to detect occult pulmonary aspiration of gastric contents. A complication of diagnostic endoscopy is aspiration of contents even in fasted patients. The authors have studied 21 hospitalized patients who underwent elective endoscopy (END) for suspected UGI pathology. Fifteen minutes before END, and prior to pharygeal anesthesia, 1 mCi Tc-99m-sulfur colloid, added to the usual 30cc of simethicone routinely administered before END, was given orally. END was performed as usual and 2 hours later anterior 100,000 count images of the chest were obtained. All the studies were interpreted without history or clinical information. Fevermore » developed within 24 hours (and septic shock in 1) in both patients with positive studies while no fever occurred in the remaining patients with negative studies (rho<.001). The authors conclude that oral radionuclide pulmonary aspiration studies may; detect aspiration not recognized by the endoscopist, reveal evidence of aspiration that preceeds adverse clinical signs and symptoms, and be influenced by systemic pre-END drugs known to affect GI secretions and motility.« less

  17. Clinical indicators for routine use in the evaluation of early psychosis intervention: development, training support and inter-rater reliability.

    PubMed

    Catts, Stanley V; Frost, Aaron D J; O'Toole, Brian I; Carr, Vaughan J; Lewin, Terry; Neil, Amanda L; Harris, Meredith G; Evans, Russell W; Crissman, Belinda R; Eadie, Kathy

    2011-01-01

    Clinical practice improvement carried out in a quality assurance framework relies on routinely collected data using clinical indicators. Herein we describe the development, minimum training requirements, and inter-rater agreement of indicators that were used in an Australian multi-site evaluation of the effectiveness of early psychosis (EP) teams. Surveys of clinician opinion and face-to-face consensus-building meetings were used to select and conceptually define indicators. Operationalization of definitions was achieved by iterative refinement until clinicians could be quickly trained to code indicators reliably. Calculation of percentage agreement with expert consensus coding was based on ratings of paper-based clinical vignettes embedded in a 2-h clinician training package. Consensually agreed upon conceptual definitions for seven clinical indicators judged most relevant to evaluating EP teams were operationalized for ease-of-training. Brief training enabled typical clinicians to code indicators with acceptable percentage agreement (60% to 86%). For indicators of suicide risk, psychosocial function, and family functioning this level of agreement was only possible with less precise 'broad range' expert consensus scores. Estimated kappa values indicated fair to good inter-rater reliability (kappa > 0.65). Inspection of contingency tables (coding category by health service) and modal scores across services suggested consistent, unbiased coding across services. Clinicians are able to agree upon what information is essential to routinely evaluate clinical practice. Simple indicators of this information can be designed and coding rules can be reliably applied to written vignettes after brief training. The real world feasibility of the indicators remains to be tested in field trials.

  18. Impact of a Routine, Opt-Out HIV Testing Program on HIV Testing and Case Detection in North Carolina Sexually-Transmitted Disease Clinics

    PubMed Central

    Klein, Pamela W.; Messer, Lynne C.; Myers, Evan R.; Weber, David J.; Leone, Peter A.; Miller, William C.

    2016-01-01

    The impact of routine, opt-out HIV testing programs in clinical settings is inconclusive. The objective of this study was to estimate the impact of an expanded, routine HIV testing program in North Carolina sexually transmitted disease (STD) clinics on HIV testing and case detection. Adults aged 18–64 who received an HIV test in a North Carolina STD clinic July 1, 2005 through June 30, 2011 were included in this analysis, dichotomized at the date of implementation on November 1, 2007. HIV testing and case detection counts and rates were analyzed using interrupted time series analysis, and Poisson and multilevel logistic regression. Pre-intervention, 426 new HIV-infected cases were identified from 128,029 tests (0.33%), whereas 816 new HIV-infected cases were found from 274,745 tests post-intervention (0.30%). Pre-intervention, HIV testing increased by 55 tests per month (95% confidence interval [CI]: 41, 72), but only 34 tests per month (95% CI: 26, 42) post-intervention. Increases in HIV testing rates were most pronounced in females and non-Hispanic whites. A slight pre-intervention decline in case detection was mitigated by the intervention (mean difference [MD]=0.01; 95% CI: −0.02, 0.05). Increases in case detection rates were observed among females and non-Hispanic blacks. The impact of a routine HIV screening in North Carolina STD clinics was marginal, with the greatest benefit among persons not traditionally targeted for HIV testing. The use of a pre-intervention comparison period identified important temporal trends that otherwise would have been ignored. PMID:24825338

  19. The Current State and Path Forward For Enterprise Image Viewing: HIMSS-SIIM Collaborative White Paper.

    PubMed

    Roth, Christopher J; Lannum, Louis M; Dennison, Donald K; Towbin, Alexander J

    2016-10-01

    Clinical specialties have widely varied needs for diagnostic image interpretation, and clinical image and video image consumption. Enterprise viewers are being deployed as part of electronic health record implementations to present the broad spectrum of clinical imaging and multimedia content created in routine medical practice today. This white paper will describe the enterprise viewer use cases, drivers of recent growth, technical considerations, functionality differences between enterprise and specialty viewers, and likely future states. This white paper is aimed at CMIOs and CIOs interested in optimizing the image-enablement of their electronic health record or those who may be struggling with the many clinical image viewers their enterprises may employ today.

  20. FFDM image quality assessment using computerized image texture analysis

    NASA Astrophysics Data System (ADS)

    Berger, Rachelle; Carton, Ann-Katherine; Maidment, Andrew D. A.; Kontos, Despina

    2010-04-01

    Quantitative measures of image quality (IQ) are routinely obtained during the evaluation of imaging systems. These measures, however, do not necessarily correlate with the IQ of the actual clinical images, which can also be affected by factors such as patient positioning. No quantitative method currently exists to evaluate clinical IQ. Therefore, we investigated the potential of using computerized image texture analysis to quantitatively assess IQ. Our hypothesis is that image texture features can be used to assess IQ as a measure of the image signal-to-noise ratio (SNR). To test feasibility, the "Rachel" anthropomorphic breast phantom (Model 169, Gammex RMI) was imaged with a Senographe 2000D FFDM system (GE Healthcare) using 220 unique exposure settings (target/filter, kVs, and mAs combinations). The mAs were varied from 10%-300% of that required for an average glandular dose (AGD) of 1.8 mGy. A 2.5cm2 retroareolar region of interest (ROI) was segmented from each image. The SNR was computed from the ROIs segmented from images linear with dose (i.e., raw images) after flat-field and off-set correction. Image texture features of skewness, coarseness, contrast, energy, homogeneity, and fractal dimension were computed from the Premium ViewTM postprocessed image ROIs. Multiple linear regression demonstrated a strong association between the computed image texture features and SNR (R2=0.92, p<=0.001). When including kV, target and filter as additional predictor variables, a stronger association with SNR was observed (R2=0.95, p<=0.001). The strong associations indicate that computerized image texture analysis can be used to measure image SNR and potentially aid in automating IQ assessment as a component of the clinical workflow. Further work is underway to validate our findings in larger clinical datasets.

  1. Achieving Routine Submillisievert CT Scanning: Report from the Summit on Management of Radiation Dose in CT

    PubMed Central

    Chen, Guang Hong; Kalender, Willi; Leng, Shuai; Samei, Ehsan; Taguchi, Katsuyuki; Wang, Ge; Yu, Lifeng; Pettigrew, Roderic I.

    2012-01-01

    This Special Report presents the consensus of the Summit on Management of Radiation Dose in Computed Tomography (CT) (held in February 2011), which brought together participants from academia, clinical practice, industry, and regulatory and funding agencies to identify the steps required to reduce the effective dose from routine CT examinations to less than 1 mSv. The most promising technologies and methods discussed at the summit include innovations and developments in x-ray sources; detectors; and image reconstruction, noise reduction, and postprocessing algorithms. Access to raw projection data and standard data sets for algorithm validation and optimization is a clear need, as is the need for new, clinically relevant metrics of image quality and diagnostic performance. Current commercially available techniques such as automatic exposure control, optimization of tube potential, beam-shaping filters, and dynamic z-axis collimators are important, and education to successfully implement these methods routinely is critically needed. Other methods that are just becoming widely available, such as iterative reconstruction, noise reduction, and postprocessing algorithms, will also have an important role. Together, these existing techniques can reduce dose by a factor of two to four. Technical advances that show considerable promise for additional dose reduction but are several years or more from commercial availability include compressed sensing, volume of interest and interior tomography techniques, and photon-counting detectors. This report offers a strategic roadmap for the CT user and research and manufacturer communities toward routinely achieving effective doses of less than 1 mSv, which is well below the average annual dose from naturally occurring sources of radiation. © RSNA, 2012 PMID:22692035

  2. Development of photoacoustic imaging technology overlaid on ultrasound imaging and its clinical application

    NASA Astrophysics Data System (ADS)

    Ishihara, Miya; Tsujita, Kazuhiro; Horiguchi, Akio; Irisawa, Kaku; Komatsu, Tomohiro; Ayaori, Makoto; Hirasawa, Takeshi; Kasamatsu, Tadashi; Hirota, Kazuhiro; Tsuda, Hitoshi; Ikewaki, Katsunori; Asano, Tomohiko

    2015-03-01

    Purpose: Photoacoustic imaging (PAI) enables one to visualize the distribution of hemoglobin and acquire a map of microvessels without using contrast agents. The purpose of our study is to develop a clinically applicable PAI system integrated with a clinical ultrasound (US) array system with handheld PAI probes providing coregistered PAI and US images. Clinical research trials were performed to evaluate the performance and feasibility of clinical value. Materials and Methods: We developed two types of handheld PAI probes: a linear PAI probe combining a conventional linear-array US probe with optical illumination and a transrectal ultrasonography (TRUS)-type PAI probe. We performed experiments with Japanese white rabbits and conducted clinical research trials of urology and vascular medicine with the approval of the medical human ethics committee of the National Defense Medical College. Results: We successfully acquired high-dynamic-range images of the vascular network ranging from capillaries to landmark arteries and identified the femoral vein, deep femoral vein, and great saphenous vein of rabbits. These major vessels in the rabbits groin are surrounded with microvessels connected to each other. Periprostatic microvessels were monitored during radical prostatectomy for localized prostate cancer and they were colocalized with nerve fibers, and their distribution was consistent with the corresponding PAI. The TRUS-type PAI probe clearly demonstrated the location and extent of the neurovascular bundle (NVB) better than does TRUS alone. Conclusions: The system, which can obtain a PAI, a US image, and a merged image, was innovatively designed so that medical doctors can easily find the location without any prior knowledge or extended skills to analyze the obtained images. Our pilot feasibility study confirms that PAI could be an imaging modality useful in the screening study and diagnostic biopsy.

  3. Online Magnetic Resonance Image Guided Adaptive Radiation Therapy: First Clinical Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Acharya, Sahaja; Fischer-Valuck, Benjamin W.; Kashani, Rojano

    Purpose: To demonstrate the feasibility of online adaptive magnetic resonance (MR) image guided radiation therapy (MR-IGRT) through reporting of our initial clinical experience and workflow considerations. Methods and Materials: The first clinically deployed online adaptive MR-IGRT system consisted of a split 0.35T MR scanner straddling a ring gantry with 3 multileaf collimator-equipped {sup 60}Co heads. The unit is supported by a Monte Carlo–based treatment planning system that allows real-time adaptive planning with the patient on the table. All patients undergo computed tomography and MR imaging (MRI) simulation for initial treatment planning. A volumetric MRI scan is acquired for each patient atmore » the daily treatment setup. Deformable registration is performed using the planning computed tomography data set, which allows for the transfer of the initial contours and the electron density map to the daily MRI scan. The deformed electron density map is then used to recalculate the original plan on the daily MRI scan for physician evaluation. Recontouring and plan reoptimization are performed when required, and patient-specific quality assurance (QA) is performed using an independent in-house software system. Results: The first online adaptive MR-IGRT treatments consisted of 5 patients with abdominopelvic malignancies. The clinical setting included neoadjuvant colorectal (n=3), unresectable gastric (n=1), and unresectable pheochromocytoma (n=1). Recontouring and reoptimization were deemed necessary for 3 of 5 patients, and the initial plan was deemed sufficient for 2 of the 5 patients. The reasons for plan adaptation included tumor progression or regression and a change in small bowel anatomy. In a subsequently expanded cohort of 170 fractions (20 patients), 52 fractions (30.6%) were reoptimized online, and 92 fractions (54.1%) were treated with an online-adapted or previously adapted plan. The median time for recontouring, reoptimization, and QA was 26

  4. Introduction to clinical and laboratory (small-animal) image registration and fusion.

    PubMed

    Zanzonico, Pat B; Nehmeh, Sadek A

    2006-01-01

    Imaging has long been a vital component of clinical medicine and, increasingly, of biomedical research in small-animals. Clinical and laboratory imaging modalities can be divided into two general categories, structural (or anatomical) and functional (or physiological). The latter, in particular, has spawned what has come to be known as "molecular imaging". Image registration and fusion have rapidly emerged as invaluable components of both clinical and small-animal imaging and has lead to the development and marketing of a variety of multi-modality, e.g. PET-CT, devices which provide registered and fused three-dimensional image sets. This paper briefly reviews the basics of image registration and fusion and available clinical and small-animal multi-modality instrumentation.

  5. [Proton imaging applications for proton therapy: state of the art].

    PubMed

    Amblard, R; Floquet, V; Angellier, G; Hannoun-Lévi, J M; Hérault, J

    2015-04-01

    Proton therapy allows a highly precise tumour volume irradiation with a low dose delivered to the healthy tissues. The steep dose gradients observed and the high treatment conformity require a precise knowledge of the proton range in matter and the target volume position relative to the beam. Thus, proton imaging allows an improvement of the treatment accuracy, and thereby, in treatment quality. Initially suggested in 1963, radiographic imaging with proton is still not used in clinical routine. The principal difficulty is the lack of spatial resolution, induced by the multiple Coulomb scattering of protons with nuclei. Moreover, its realization for all clinical locations requires relatively high energies that are previously not considered for clinical routine. Abandoned for some time in favor of X-ray technologies, research into new imaging methods using protons is back in the news because of the increase of proton radiation therapy centers in the world. This article exhibits a non-exhaustive state of the art in proton imaging. Copyright © 2015 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  6. The relationship of interictal epileptiform discharges to clinical epilepsy severity: A study of routine EEGs and review of the literature

    PubMed Central

    Selvitelli, Megan F.; Walker, Linsey M.; Schomer, Donald L.; Chang, Bernard S.

    2010-01-01

    Purpose EEGs are widely used to detect interictal epileptiform discharges (IEDs) in patients with a known history of seizures. However, prior studies have not found a consistent association between the presence or frequency of IEDs and clinical epilepsy severity, possibly because of differences in subject characteristics and recording techniques. We sought to investigate this relationship in a population and setting reflective of the most common clinical usage. Methods We analyzed EEGs and clinical records of all consenting patients with a history of at least two presumed focal-onset seizures who presented for routine EEG recording over one year’s time in an academic neurophysiology laboratory (n = 129). Results Despite adequate statistical power, we did not find an association between the presence or absence of IEDs or IED frequency and the most recently determined seizure frequency (median 4 per year). A higher IED incidence was seen in subjects with longer epilepsy duration (p = 0.04). Neither IED incidence nor frequency (median 10.0 per hour) correlated with age or antiepileptic drug use. Conclusions Our results differ from those of some prior studies, most of which focused on more narrow subject populations, suggesting that the patient’s clinical circumstances must be taken into account before assuming the utility of IEDs on routine EEG in predicting epilepsy severity. PMID:20234317

  7. Endogenous glucocorticoid analysis by liquid chromatography-tandem mass spectrometry in routine clinical laboratories.

    PubMed

    Hawley, James M; Keevil, Brian G

    2016-09-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a powerful analytical technique that offers exceptional selectivity and sensitivity. Used optimally, LC-MS/MS provides accurate and precise results for a wide range of analytes at concentrations that are difficult to quantitate with other methodologies. Its implementation into routine clinical biochemistry laboratories has revolutionised our ability to analyse small molecules such as glucocorticoids. Whereas immunoassays can suffer from matrix effects and cross-reactivity due to interactions with structural analogues, the selectivity offered by LC-MS/MS has largely overcome these limitations. As many clinical guidelines are now beginning to acknowledge the importance of the methodology used to provide results, the advantages associated with LC-MS/MS are gaining wider recognition. With their integral role in both the diagnosis and management of hypo- and hyperadrenal disorders, coupled with their widespread pharmacological use, the accurate measurement of glucocorticoids is fundamental to effective patient care. Here, we provide an up-to-date review of the LC-MS/MS techniques used to successfully measure endogenous glucocorticoids, particular reference is made to serum, urine and salivary cortisol. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Usefulness of component resolved analysis of cat allergy in routine clinical practice.

    PubMed

    Eder, Katharina; Becker, Sven; San Nicoló, Marion; Berghaus, Alexander; Gröger, Moritz

    2016-01-01

    Cat allergy is of great importance, and its prevalence is increasing worldwide. Cat allergens and house dust mite allergens represent the major indoor allergens; however, they are ubiquitous. Cat sensitization and allergy are known risk factors for rhinitis, bronchial hyperreactivity and asthma. Thus, the diagnosis of sensitization to cats is important for any allergist. 70 patients with positive skin prick tests for cats were retrospectively compared regarding their skin prick test results, as well as their specific immunoglobulin E antibody profiles with regard to their responses to the native cat extract, rFel d 1, nFel d 2 and rFel d 4. 35 patients were allergic to cats, as determined by positive anamnesis and/or nasal provocation with cat allergens, and 35 patients exhibited clinically non-relevant sensitization, as indicated by negative anamnesis and/or a negative nasal allergen challenge. Native cat extract serology testing detected 100% of patients who were allergic to cats but missed eight patients who showed sensitization in the skin prick test and did not have allergic symptoms. The median values of the skin prick test, as well as those of the specific immunoglobulin E antibodies against the native cat extract, were significantly higher for allergic patients than for patients with clinically non-relevant sensitization. Component based diagnostic testing to rFel d 1 was not as reliable. Sensitization to nFel d 2 and rFel d 4 was seen only in individual patients. Extract based diagnostic methods for identifying cat allergy and sensitization, such as the skin prick test and native cat extract serology, remain crucial in routine clinical practice. In our study, component based diagnostic testing could not replace these methods with regard to the detection of sensitization to cats and differentiation between allergy and sensitization without clinical relevance. However, component resolved allergy diagnostic tools have individual implications, and future

  9. Post-standardization of routine creatinine assays: are they suitable for clinical applications.

    PubMed

    Jassam, Nuthar; Weykamp, Cas; Thomas, Annette; Secchiero, Sandra; Sciacovelli, Laura; Plebani, Mario; Thelen, Marc; Cobbaert, Christa; Perich, Carmen; Ricós, Carmen; Paula, Faria A; Barth, Julian H

    2017-05-01

    Introduction Reliable serum creatinine measurements are of vital importance for the correct classification of chronic kidney disease and early identification of kidney injury. The National Kidney Disease Education Programme working group and other groups have defined clinically acceptable analytical limits for creatinine methods. The aim of this study was to re-evaluate the performance of routine creatinine methods in the light of these defined limits so as to assess their suitability for clinical practice. Method In collaboration with the Dutch External Quality Assurance scheme, six frozen commutable samples, with a creatinine concentration ranging from 80 to 239  μmol/L and traceable to isotope dilution mass spectrometry, were circulated to 91 laboratories in four European countries for creatinine measurement and estimated glomerular filtration rate calculation. Two out of the six samples were spiked with glucose to give high and low final concentrations of glucose. Results Results from 89 laboratories were analysed for bias, imprecision (%CV) for each creatinine assay and total error for estimated glomerular filtration rate. The participating laboratories used analytical instruments from four manufacturers; Abbott, Beckman, Roche and Siemens. All enzymatic methods in this study complied with the National Kidney Disease Education Programme working group recommended limits of bias of 5% above a creatinine concentration of 100  μmol/L. They also did not show any evidence of interference from glucose. In addition, they also showed compliance with the clinically recommended %CV of ≤4% across the analytical range. In contrast, the Jaffe methods showed variable performance with regard to the interference of glucose and unsatisfactory bias and precision. Conclusion Jaffe-based creatinine methods still exhibit considerable analytical variability in terms of bias, imprecision and lack of specificity, and this variability brings into question their clinical utility

  10. Towards clinically translatable in vivo nanodiagnostics

    NASA Astrophysics Data System (ADS)

    Park, Seung-Min; Aalipour, Amin; Vermesh, Ophir; Yu, Jung Ho; Gambhir, Sanjiv S.

    2017-05-01

    Nanodiagnostics as a field makes use of fundamental advances in nanobiotechnology to diagnose, characterize and manage disease at the molecular scale. As these strategies move closer to routine clinical use, a proper understanding of different imaging modalities, relevant biological systems and physical properties governing nanoscale interactions is necessary to rationally engineer next-generation bionanomaterials. In this Review, we analyse the background physics of several clinically relevant imaging modalities and their associated sensitivity and specificity, provide an overview of the materials currently used for in vivo nanodiagnostics, and assess the progress made towards clinical translation. This work provides a framework for understanding both the impressive progress made thus far in the nanodiagnostics field as well as presenting challenges that must be overcome to obtain widespread clinical adoption.

  11. Sequencing-based breast cancer diagnostics as an alternative to routine biomarkers.

    PubMed

    Rantalainen, Mattias; Klevebring, Daniel; Lindberg, Johan; Ivansson, Emma; Rosin, Gustaf; Kis, Lorand; Celebioglu, Fuat; Fredriksson, Irma; Czene, Kamila; Frisell, Jan; Hartman, Johan; Bergh, Jonas; Grönberg, Henrik

    2016-11-30

    Sequencing-based breast cancer diagnostics have the potential to replace routine biomarkers and provide molecular characterization that enable personalized precision medicine. Here we investigate the concordance between sequencing-based and routine diagnostic biomarkers and to what extent tumor sequencing contributes clinically actionable information. We applied DNA- and RNA-sequencing to characterize tumors from 307 breast cancer patients with replication in up to 739 patients. We developed models to predict status of routine biomarkers (ER, HER2,Ki-67, histological grade) from sequencing data. Non-routine biomarkers, including mutations in BRCA1, BRCA2 and ERBB2(HER2), and additional clinically actionable somatic alterations were also investigated. Concordance with routine diagnostic biomarkers was high for ER status (AUC = 0.95;AUC(replication) = 0.97) and HER2 status (AUC = 0.97;AUC(replication) = 0.92). The transcriptomic grade model enabled classification of histological grade 1 and histological grade 3 tumors with high accuracy (AUC = 0.98;AUC(replication) = 0.94). Clinically actionable mutations in BRCA1, BRCA2 and ERBB2(HER2) were detected in 5.5% of patients, while 53% had genomic alterations matching ongoing or concluded breast cancer studies. Sequencing-based molecular profiling can be applied as an alternative to histopathology to determine ER and HER2 status, in addition to providing improved tumor grading and clinically actionable mutations and molecular subtypes. Our results suggest that sequencing-based breast cancer diagnostics in a near future can replace routine biomarkers.

  12. Age and sex based reference values for incidental coronary artery and thoracic aorta calcifications on routine clinical chest CT: a powerful tool to appreciate available imaging findings.

    PubMed

    Jairam, Pushpa M; de Jong, Pim A; Mali, Willem P Th M; Gondrie, Martijn J A; Jacobs, Peter C A; van der Graaf, Yolanda

    2014-08-01

    To establish age and gender specific reference values for incidental coronary artery and thoracic aorta calcification scores on routine diagnostic CT scans. These reference values can aid in structured reporting and interpretation of readily available imaging data by chest CT readers in routine practice. A random sample of 1572 (57% male, median age 61 years) was taken from a study population of 12,063 subjects who underwent diagnostic chest CT for non-cardiovascular indications between January 2002 and December 2005. Coronary artery and thoracic aorta calcifications were graded using a validated ordinal score. The 25th, 50th and 75th percentile cut points were calculated for the coronary artery and thoracic aorta calcification scores within each age/gender stratum. The 75th percentile cut points for coronary artery calcification scores were higher for men than for women across all age groups, with the exception of the lowest age group. The 75th percentile cut points for thoracic aorta calcifications scores were comparable for both genders across all age groups. Based on the obtained age and gender reference values a calculation tool is provided, that allows one to enter an individual's age, gender and calcification scores to obtain the corresponding estimated percentiles. The calculation tool as provided in this study can be used in daily practice by CT readers to examine whether a subject has high calcifications scores relative to others with the same age and gender. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Effectiveness of Sucrose Used Routinely for Pain Relief and Neonatal Clinical Risk in Preterm Infants: A Nonrandomized Study.

    PubMed

    Valeri, Beatriz Oliveira; Gaspardo, Cláudia Maria; Martinez, Francisco Eulógio; Linhares, Maria Beatriz Martins

    2018-01-03

    Preterm infants (PI) requiring the Neonatal Intensive Care Unit (NICU) are exposed to early repetitive pain/distress. Little is known about how pain relief strategies interact with infants'clinical health status, such as severity of illness with pain responses. This study aimed to examine main and interactive effects of routine sucrose intervention and neonatal clinical risk (NCR) on biobehavioral pain reactivity-recovery in PI during painful blood collection procedures. Very-low birthweight PI (n=104) were assigned to Low and High Clinical Risk Groups, according to the Clinical Risk Index for Babies. Sucrose-Group (SG; n=52) received sucrose solution (25%; 0.5▒mL/Kg) two minutes before the procedures and Control-Group (CG) received standard-care. Biobehavioral pain reactivity-recovery was assessed according to the Neonatal Facial Coding System, Sleep-wake state scale, crying time, and heart rate (HR) at five phases (Baseline, Antisepsis, Puncture, Recovery-Dressing and Recovery-Resting). Repeated measure ANOVA with mixed-design was performed considering pain assessment phases, intervention group, and NCR. Independent of NCR, sucrose presented main effect in decreasing neonates' facial activity pain responses and crying time, during Puncture and Recovery-Resting. Independent of NCR level or routine sucrose intervention, all neonates displayed activated state in Puncture and decreased biobehavioral responses in Recovery-Resting phase. Although no sucrose or NCR effects were observed on physiological reactivity, all neonates exhibited physiological recovery 10 minutes after puncture, reaching the same HR patterns as the Baseline. Independent of NCR level, sucrose intervention for pain relief during acute painful procedures was effective to reduce pain intensity and increase biobehavioral regulation.

  14. Feasibility of real-time capture of routine clinical data in the electronic health record: a hospital-based, observational service-evaluation study

    PubMed Central

    Archbold, R Andrew; Weerackody, Roshan; Barnes, Michael R; Lee, Aaron M; Janjuha, Surjeet; Gutteridge, Charles; Robson, John; Timmis, Adam

    2018-01-01

    Objectives The electronic health record (EHR) is underused in the hospital setting. The aim of this service evaluation study was to respond to National Health Service (NHS) Digital’s ambition for a paperless NHS by capturing routinely collected cardiac outpatient data in the EHR to populate summary patient reports and provide a resource for audit and research. Design A PowerForm template was developed within the Cerner EHR, for real-time entry of routine clinical data by clinicians attending a cardiac outpatient clinic. Data captured within the PowerForm automatically populated a SmartTemplate to generate a view-only report that was immediately available for the patient and for electronic transmission to the referring general practitioner (GP). Results During the first 8 months, the PowerForm template was used in 61% (360/594) of consecutive outpatient referrals increasing from 42% to 77% during the course of the study. Structured patient reports were available for immediate sharing with the referring GP using Cerner Health Information Exchange technology while electronic transmission was successfully developed in a substudy of 64 cases, with direct delivery by the NHS Data Transfer Service in 29 cases and NHS mail in the remainder. In feedback, the report’s immediate availability was considered very or extremely important by >80% of the patients and GPs who were surveyed. Both groups reported preference of the patient report to the conventional typed letter. Deidentified template data for all 360 patients were successfully captured within the Trust system, confirming availability of these routinely collected outpatient data for audit and research. Conclusion Electronic template development tailored to the requirements of a specialist outpatient clinic facilitates capture of routinely collected data within the Cerner EHR. These data can be made available for audit and research. They can also be used to enhance communication by populating structured reports

  15. Using PACS and wavelet-based image compression in a wide-area network to support radiation therapy imaging applications for satellite hospitals

    NASA Astrophysics Data System (ADS)

    Smith, Charles L.; Chu, Wei-Kom; Wobig, Randy; Chao, Hong-Yang; Enke, Charles

    1999-07-01

    An ongoing PACS project at our facility has been expanded to include providing and managing images used for routine clinical operation of the department of radiation oncology. The intent of our investigation has been to enable out clinical radiotherapy service to enter the tele-medicine environment through the use of a PACS system initially implemented in the department of radiology. The backbone for the imaging network includes five CT and three MR scanners located across three imaging centers. A PC workstation in the department of radiation oncology was used to transmit CT imags to a satellite facility located approximately 60 miles from the primary center. Chest CT images were used to analyze network transmission performance. Connectivity established between the primary department and satellite has fulfilled all image criteria required by the oncologist. Establishing the link tot eh oncologist at the satellite diminished bottlenecking of imaging related tasks at the primary facility due to physician absence. A 30:1 compression ratio using a wavelet-based algorithm provided clinically acceptable images treatment planning. Clinical radiotherapy images can be effectively managed in a wide- area-network to link satellite facilities to larger clinical centers.

  16. How Imaging Can Impact Clinical Trial Design: Molecular Imaging as a Biomarker for Targeted Cancer Therapy.

    PubMed

    Mankoff, David A; Farwell, Michael D; Clark, Amy S; Pryma, Daniel A

    2015-01-01

    The ability to measure biochemical and molecular processes to guide cancer treatment represents a potentially powerful tool for trials of targeted cancer therapy. These assays have traditionally been performed by analysis of tissue samples. However, more recently, functional and molecular imaging has been developed that is capable of in vivo assays of cancer biochemistry and molecular biology and is highly complementary to tissue-based assays. Cancer imaging biomarkers can play a key role in increasing the efficacy and efficiency of therapeutic clinical trials and also provide insight into the biologic mechanisms that bring about a therapeutic response. Future progress will depend on close collaboration between imaging scientists and cancer physicians and on public and commercial sponsors, to take full advantage of what imaging has to offer for clinical trials of targeted cancer therapy. This review will provide examples of how molecular imaging can inform targeted cancer clinical trials and clinical decision making by (1) measuring regional expression of the therapeutic target, (2) assessing early (pharmacodynamic) response to treatment, and (3) predicting therapeutic outcome. The review includes a discussion of basic principles of molecular imaging biomarkers in cancer, with an emphasis on those methods that have been tested in patients. We then review clinical trials designed to evaluate imaging tests as integrated markers embedded in a therapeutic clinical trial with the goal of validating the imaging tests as integral markers that can aid patient selection and direct response-adapted treatment strategies. Examples of recently completed multicenter trials using imaging biomarkers are highlighted.

  17. Differentiating tumor recurrence from treatment necrosis: a review of neuro-oncologic imaging strategies

    PubMed Central

    Verma, Nishant; Cowperthwaite, Matthew C.; Burnett, Mark G.; Markey, Mia K.

    2013-01-01

    Abstract Differentiating treatment-induced necrosis from tumor recurrence is a central challenge in neuro-oncology. These 2 very different outcomes after brain tumor treatment often appear similarly on routine follow-up imaging studies. They may even manifest with similar clinical symptoms, further confounding an already difficult process for physicians attempting to characterize a new contrast-enhancing lesion appearing on a patient's follow-up imaging. Distinguishing treatment necrosis from tumor recurrence is crucial for diagnosis and treatment planning, and therefore, much effort has been put forth to develop noninvasive methods to differentiate between these disparate outcomes. In this article, we review the latest developments and key findings from research studies exploring the efficacy of structural and functional imaging modalities for differentiating treatment necrosis from tumor recurrence. We discuss the possibility of computational approaches to investigate the usefulness of fine-grained imaging characteristics that are difficult to observe through visual inspection of images. We also propose a flexible treatment-planning algorithm that incorporates advanced functional imaging techniques when indicated by the patient's routine follow-up images and clinical condition. PMID:23325863

  18. Safety of ranibizumab in routine clinical practice: 1-year retrospective pooled analysis of four European neovascular AMD registries within the LUMINOUS programme.

    PubMed

    Holz, Frank G; Bandello, Francesco; Gillies, Mark; Mitchell, Paul; Osborne, Aaron; Sheidow, Tom; Souied, Eric; Figueroa, Marta S

    2013-09-01

    Evaluation of 1-year safety profile of intravitreal ranibizumab 0.5 mg in neovascular age-related macular degeneration (NV-AMD) within routine clinical practice. The LUMINOUS programme comprises a prospective observational study assessing ranibizumab 'real-world' safety and clinical effectiveness across licensed indications worldwide and an annual retrospective pooled safety analysis from completed NV-AMD ranibizumab registries. 1-year data from four European registries are available. This retrospective pooled safety analysis assessed 1-year incidence rates for safety events of particular interest (key ocular or systemic events possibly related to the injection procedure or vascular endothelial growth factor inhibition) together with treatment exposure. Patients were treated according to local protocols within the ranibizumab licence. Data of 4444 patients from registries in Germany (n=3470), the Netherlands (n=243), Belgium (n=260) and Sweden (n=471) were retrospectively pooled. Between 70.4% and 84.4% of enrolled patients completed 1 year of follow-up. Most frequent overall ocular events of particular interest were retinal pigment epithelial tears (27 patients; <1%) and intraocular pressure-related events (12 patients; <0.3%). Most frequent non-ocular event of particular interest was stroke (19 patients; 0.4%); annual incidence of stroke was low across all registries (0.0-0.5%). Ranibizumab demonstrated favourable 1-year safety profile for NV-AMD in this routine clinical practice sample, consistent with previous reported trial data. Additional data from a larger patient population are needed to better describe the long-term safety profile of ranibizumab in routine clinical practice and further evaluate risk for infrequent but serious events in 'real-life' settings. The 5-year LUMINOUS prospective observational study will address this need.

  19. Benchmarking routine psychological services: a discussion of challenges and methods.

    PubMed

    Delgadillo, Jaime; McMillan, Dean; Leach, Chris; Lucock, Mike; Gilbody, Simon; Wood, Nick

    2014-01-01

    Policy developments in recent years have led to important changes in the level of access to evidence-based psychological treatments. Several methods have been used to investigate the effectiveness of these treatments in routine care, with different approaches to outcome definition and data analysis. To present a review of challenges and methods for the evaluation of evidence-based treatments delivered in routine mental healthcare. This is followed by a case example of a benchmarking method applied in primary care. High, average and poor performance benchmarks were calculated through a meta-analysis of published data from services working under the Improving Access to Psychological Therapies (IAPT) Programme in England. Pre-post treatment effect sizes (ES) and confidence intervals were estimated to illustrate a benchmarking method enabling services to evaluate routine clinical outcomes. High, average and poor performance ES for routine IAPT services were estimated to be 0.91, 0.73 and 0.46 for depression (using PHQ-9) and 1.02, 0.78 and 0.52 for anxiety (using GAD-7). Data from one specific IAPT service exemplify how to evaluate and contextualize routine clinical performance against these benchmarks. The main contribution of this report is to summarize key recommendations for the selection of an adequate set of psychometric measures, the operational definition of outcomes, and the statistical evaluation of clinical performance. A benchmarking method is also presented, which may enable a robust evaluation of clinical performance against national benchmarks. Some limitations concerned significant heterogeneity among data sources, and wide variations in ES and data completeness.

  20. A Foundation for Enterprise Imaging: HIMSS-SIIM Collaborative White Paper.

    PubMed

    Roth, Christopher J; Lannum, Louis M; Persons, Kenneth R

    2016-10-01

    Care providers today routinely obtain valuable clinical multimedia with mobile devices, scope cameras, ultrasound, and many other modalities at the point of care. Image capture and storage workflows may be heterogeneous across an enterprise, and as a result, they often are not well incorporated in the electronic health record. Enterprise Imaging refers to a set of strategies, initiatives, and workflows implemented across a healthcare enterprise to consistently and optimally capture, index, manage, store, distribute, view, exchange, and analyze all clinical imaging and multimedia content to enhance the electronic health record. This paper is intended to introduce Enterprise Imaging as an important initiative to clinical and informatics leadership, and outline its key elements of governance, strategy, infrastructure, common multimedia content, acquisition workflows, enterprise image viewers, and image exchange services.

  1. Availability of color calibration for consistent color display in medical images and optimization of reference brightness for clinical use

    NASA Astrophysics Data System (ADS)

    Iwai, Daiki; Suganami, Haruka; Hosoba, Minoru; Ohno, Kazuko; Emoto, Yutaka; Tabata, Yoshito; Matsui, Norihisa

    2013-03-01

    Color image consistency has not been accomplished yet except the Digital Imaging and Communication in Medicine (DICOM) Supplement 100 for implementing a color reproduction pipeline and device independent color spaces. Thus, most healthcare enterprises could not check monitor degradation routinely. To ensure color consistency in medical color imaging, monitor color calibration should be introduced. Using simple color calibration device . chromaticity of colors including typical color (Red, Green, Blue, Green and White) are measured as device independent profile connection space value called u'v' before and after calibration. In addition, clinical color images are displayed and visual differences are observed. In color calibration, monitor brightness level has to be set to quite lower value 80 cd/m2 according to sRGB standard. As Maximum brightness of most color monitors available currently for medical use have much higher brightness than 80 cd/m2, it is not seemed to be appropriate to use 80 cd/m2 level for calibration. Therefore, we propose that new brightness standard should be introduced while maintaining the color representation in clinical use. To evaluate effects of brightness to chromaticity experimentally, brightness level is changed in two monitors from 80 to 270cd/m2 and chromaticity value are compared with each brightness levels. As a result, there are no significant differences in chromaticity diagram when brightness levels are changed. In conclusion, chromaticity is close to theoretical value after color calibration. Moreover, chromaticity isn't moved when brightness is changed. The results indicate optimized reference brightness level for clinical use could be set at high brightness in current monitors .

  2. Development of imaging biomarkers and generation of big data.

    PubMed

    Alberich-Bayarri, Ángel; Hernández-Navarro, Rafael; Ruiz-Martínez, Enrique; García-Castro, Fabio; García-Juan, David; Martí-Bonmatí, Luis

    2017-06-01

    Several image processing algorithms have emerged to cover unmet clinical needs but their application to radiological routine with a clear clinical impact is still not straightforward. Moving from local to big infrastructures, such as Medical Imaging Biobanks (millions of studies), or even more, Federations of Medical Imaging Biobanks (in some cases totaling to hundreds of millions of studies) require the integration of automated pipelines for fast analysis of pooled data to extract clinically relevant conclusions, not uniquely linked to medical imaging, but in combination to other information such as genetic profiling. A general strategy for the development of imaging biomarkers and their integration in the cloud for the quantitative management and exploitation in large databases is herein presented. The proposed platform has been successfully launched and is being validated nowadays among the early adopters' community of radiologists, clinicians, and medical imaging researchers.

  3. Adoption of routine telemedicine in Norway: the current picture

    PubMed Central

    Zanaboni, Paolo; Knarvik, Undine; Wootton, Richard

    2014-01-01

    Background Telemedicine appears to be ready for wider adoption. Although existing research evidence is useful, the adoption of routine telemedicine in healthcare systems has been slow. Objective We conducted a study to explore the current use of routine telemedicine in Norway, at national, regional, and local levels, to provide objective and up-to-date information and to estimate the potential for wider adoption of telemedicine. Design A top-down approach was used to collect official data on the national use of telemedicine from the Norwegian Patient Register. A bottom-up approach was used to collect complementary information on the routine use of telemedicine through a survey conducted at the five largest publicly funded hospitals. Results Results show that routine telemedicine has been adopted in all health regions in Norway and in 68% of hospitals. Despite being widely adopted, the current level of use of telemedicine is low compared to the number of face-to-face visits. Examples of routine telemedicine can be found in several clinical specialties. Most services connect different hospitals in secondary care, and they are mostly delivered as teleconsultations via videoconference. Conclusions Routine telemedicine in Norway has been widely adopted, probably for geographical reasons, as in other settings. However, the level of use of telemedicine in Norway is rather low, and it has significant potential for further development as an alternative to face-to-face outpatient visits. This study is a first attempt to map routine telemedicine at regional, institutional, and clinical levels, and it provides useful information to understand the adoption of telemedicine in routine healthcare and to measure change in future updates. PMID:24433942

  4. Cognitive-behavioural therapy for outpatients with eating disorders: effectiveness for a transdiagnostic group in a routine clinical setting.

    PubMed

    Turner, Hannah; Marshall, Emily; Stopa, Lusia; Waller, Glenn

    2015-05-01

    Whilst there is a growing evidence to support the impact of cognitive-behavioural therapy (CBT) in the treatment of adults with eating disorders, much of this evidence comes from tightly controlled efficacy trials. This study aimed to add to the evidence regarding the effectiveness of CBT when delivered in a routine clinical setting. The participants were 203 adults presenting with a range of eating disorder diagnoses, who were offered CBT in an out-patient community eating disorders service in the UK. Patients completed measures of eating disorder pathology at the start of treatment, following the sixth session, and at the end of treatment. Symptoms of anxiety, depression, and psychosocial functioning were measured pre- and post-treatment. Approximately 55% of patients completed treatment, and there were no factors that predicted attrition. There were significant improvements in eating disorder psychopathology, anxiety, depression and general functioning, with particular changes in eating attitudes in the early part of therapy. Effect sizes were medium to large for both completer and intention to treat analyses. These findings confirm that evidence-based forms of CBT can be delivered with strong outcomes in routine clinical settings. Clinicians should be encouraged to deliver evidence-based treatments when working in these settings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Shading correction for cone-beam CT in radiotherapy: validation of dose calculation accuracy using clinical images

    NASA Astrophysics Data System (ADS)

    Marchant, T. E.; Joshi, K. D.; Moore, C. J.

    2017-03-01

    Cone-beam CT (CBCT) images are routinely acquired to verify patient position in radiotherapy (RT), but are typically not calibrated in Hounsfield Units (HU) and feature non-uniformity due to X-ray scatter and detector persistence effects. This prevents direct use of CBCT for re-calculation of RT delivered dose. We previously developed a prior-image based correction method to restore HU values and improve uniformity of CBCT images. Here we validate the accuracy with which corrected CBCT can be used for dosimetric assessment of RT delivery, using CBCT images and RT plans for 45 patients including pelvis, lung and head sites. Dose distributions were calculated based on each patient's original RT plan and using CBCT image values for tissue heterogeneity correction. Clinically relevant dose metrics were calculated (e.g. median and minimum target dose, maximum organ at risk dose). Accuracy of CBCT based dose metrics was determined using an "override ratio" method where the ratio of the dose metric to that calculated on a bulk-density assigned version of the image is assumed to be constant for each patient, allowing comparison to "gold standard" CT. For pelvis and head images the proportion of dose errors >2% was reduced from 40% to 1.3% after applying shading correction. For lung images the proportion of dose errors >3% was reduced from 66% to 2.2%. Application of shading correction to CBCT images greatly improves their utility for dosimetric assessment of RT delivery, allowing high confidence that CBCT dose calculations are accurate within 2-3%.

  6. Identifying pain-related concerns in routine follow-up clinics following oral and oropharyngeal cancer.

    PubMed

    Rogers, Simon N; Cleator, Alexander J; Lowe, Derek; Ghazali, Naseem

    2012-08-10

    To describe clinical characteristics of head and neck cancer (HNC) patients with pain and those wishing to discuss pain concerns during consultation. Cross-sectional, questionnaire study using University of Washington Quality of Life, version 4 (UW-QOL) and the Patients Concerns Inventory (PCI) in disease-free, post-treatment HNC cohort. Significant pain on UW-QOL and indicating "Pain in head and neck" and "Pain elsewhere" on PCI. One hundred and seventy-seven patients completed UW-QOL and PCI. The prevalence of self-reported pain issues was 38% (67/177) comprising 25% (44/177) with significant problems despite medications and 13% (23/177) with lesser or no problems but wishing to discuss pain. Patients aged under 65 years and patients having treatment involving radiotherapy were more likely to have pain issues. Just over half, 55% (24/44) of patients with significant pain did not express a need to discuss this. Those with significant pain or others wanting to discuss pain in clinic had greater problems in physical and social-emotional functioning, reported suboptimal QOL, and also had more additional PCI items to discuss in clinic compared to those without significant pain and not wishing to discuss pain. Significant HNC-related pain is prevalent in the disease-free, posttreatment cohort. Onward referral to a specialist pain team may be beneficial. The UW-QOL and PCI package is a valuable tool that may routinely screen for significant pain in outpatient clinics.

  7. A neurophysiological study of facial numbness in multiple sclerosis: Integration with clinical data and imaging findings.

    PubMed

    Koutsis, Georgios; Kokotis, Panagiotis; Papagianni, Aikaterini E; Evangelopoulos, Maria-Eleftheria; Kilidireas, Constantinos; Karandreas, Nikolaos

    2016-09-01

    To integrate neurophysiological findings with clinical and imaging data in a consecutive series of multiple sclerosis (MS) patients developing facial numbness during the course of an MS attack. Nine consecutive patients with MS and recent-onset facial numbness were studied clinically, imaged with routine MRI, and assessed neurophysiologically with trigeminal somatosensory evoked potential (TSEP), blink reflex (BR), masseter reflex (MR), facial nerve conduction, facial muscle and masseter EMG studies. All patients had unilateral facial hypoesthesia on examination and lesions in the ipsilateral pontine tegmentum on MRI. All patients had abnormal TSEPs upon stimulation of the affected side, excepting one that was tested following remission of numbness. BR was the second most sensitive neurophysiological method with 6/9 examinations exhibiting an abnormal R1 component. The MR was abnormal in 3/6 patients, always on the affected side. Facial conduction and EMG studies were normal in all patients but one. Facial numbness was always related to abnormal TSEPs. A concomitant R1 abnormality on BR allowed localization of the responsible pontine lesion, which closely corresponded with MRI findings. We conclude that neurophysiological assessment of MS patients with facial numbness is a sensitive tool, which complements MRI, and can improve lesion localization. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Using routine clinical and administrative data to produce a dataset of attendances at Emergency Departments following self-harm.

    PubMed

    Polling, C; Tulloch, A; Banerjee, S; Cross, S; Dutta, R; Wood, D M; Dargan, P I; Hotopf, M

    2015-07-16

    Self-harm is a significant public health concern in the UK. This is reflected in the recent addition to the English Public Health Outcomes Framework of rates of attendance at Emergency Departments (EDs) following self-harm. However there is currently no source of data to measure this outcome. Routinely available data for inpatient admissions following self-harm miss the majority of cases presenting to services. We aimed to investigate (i) if a dataset of ED presentations could be produced using a combination of routinely collected clinical and administrative data and (ii) to validate this dataset against another one produced using methods similar to those used in previous studies. Using the Clinical Record Interactive Search system, the electronic health records (EHRs) used in four EDs were linked to Hospital Episode Statistics to create a dataset of attendances following self-harm. This dataset was compared with an audit dataset of ED attendances created by manual searching of ED records. The proportion of total cases detected by each dataset was compared. There were 1932 attendances detected by the EHR dataset and 1906 by the audit. The EHR and audit datasets detected 77% and 76 of all attendances respectively and both detected 82% of individual patients. There were no differences in terms of age, sex, ethnicity or marital status between those detected and those missed using the EHR method. Both datasets revealed more than double the number of self-harm incidents than could be identified from inpatient admission records. It was possible to use routinely collected EHR data to create a dataset of attendances at EDs following self-harm. The dataset detected the same proportion of attendances and individuals as the audit dataset, proved more comprehensive than the use of inpatient admission records, and did not show a systematic bias in those cases it missed.

  9. Is routine drainage necessary after pancreaticoduodenectomy?

    PubMed Central

    Wang, Qiang; Jiang, Yong-Jian; Li, Ji; Yang, Feng; Di, Yang; Yao, Lie; Jin, Chen; Fu, De-Liang

    2014-01-01

    With the development of imaging technology and surgical techniques, pancreatic resections to treat pancreatic tumors, ampulla tumors, and other pancreatic diseases have increased. Pancreaticoduodenectomy, one type of pancreatic resection, is a complex surgery with the loss of pancreatic integrity and various anastomoses. Complications after pancreaticoduodenectomy such as pancreatic fistulas and anastomosis leakage are common and significantly associated with patient outcomes. Pancreatic fistula is one of the most important postoperative complications; this condition can cause intraperitoneal hemorrhage, septic shock, or even death. An effective way has not yet been found to avoid the occurrence of pancreatic fistula. In most medical centers, the frequency of pancreatic fistula has remained between 9% and 13%. The early detection and routine drainage of anastomotic fistulas, pancreatic fistulas, bleeding, or other intra-abdominal fluid collections after pancreatic resections are considered as important and effective ways to reduce postoperative complications and the mortality rate. However, many recent studies have argued that routine drainage after abdominal operations, including pancreaticoduodenectomies, does not affect the incidence of postoperative complications. Although inserting drains after pancreatic resections continues to be a routine procedure, its necessity remains controversial. This article reviews studies of the advantages and disadvantages of routine drainage after pancreaticoduodenectomy and discusses the necessity of this procedure. PMID:25009383

  10. Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction

    NASA Astrophysics Data System (ADS)

    Hollingsworth, Kieren Grant

    2015-11-01

    MRI is often the most sensitive or appropriate technique for important measurements in clinical diagnosis and research, but lengthy acquisition times limit its use due to cost and considerations of patient comfort and compliance. Once an image field of view and resolution is chosen, the minimum scan acquisition time is normally fixed by the amount of raw data that must be acquired to meet the Nyquist criteria. Recently, there has been research interest in using the theory of compressed sensing (CS) in MR imaging to reduce scan acquisition times. The theory argues that if our target MR image is sparse, having signal information in only a small proportion of pixels (like an angiogram), or if the image can be mathematically transformed to be sparse then it is possible to use that sparsity to recover a high definition image from substantially less acquired data. This review starts by considering methods of k-space undersampling which have already been incorporated into routine clinical imaging (partial Fourier imaging and parallel imaging), and then explains the basis of using compressed sensing in MRI. The practical considerations of applying CS to MRI acquisitions are discussed, such as designing k-space undersampling schemes, optimizing adjustable parameters in reconstructions and exploiting the power of combined compressed sensing and parallel imaging (CS-PI). A selection of clinical applications that have used CS and CS-PI prospectively are considered. The review concludes by signposting other imaging acceleration techniques under present development before concluding with a consideration of the potential impact and obstacles to bringing compressed sensing into routine use in clinical MRI.

  11. Non-adherence in seniors with dementia - a serious problem of routine clinical practice.

    PubMed

    Lužný, Jan; Ivanová, Kateřina; Juríčková, Lubica

    2014-01-01

    Non-adherence to treatment in seniors with dementia is a frequent and potentially dangerous phenomenon in routine clinical practice which might lead to the inappropriate treatment of a patient, including the risk of intoxication. There might be different causes of non-adherence in patients with dementia: memory impairment, sensory disturbances, limitations in mobility, economical reasons limiting access to health care and medication. Non-adherence leads to serious clinical consequences as well as being a challenge for public health. to estimate prevalence of non-adherence in seniors with dementia and to study correlation between cognitive decline and non-adherence. Prospective study, analyzing medical records of seniors with dementia admitted to the inpatient psychogeriatric ward in the Kromeriz mental hospital from January 2010 to January 2011. Cognitive decline measured by MMSE, prevalence of Non-adherence to treatment and reasons for patient Non-adherence were studied. Non-adherence to any treatment was detected in 31.3% of seniors; memory impairment was the most common cause of non-adherence to treatment. In conclusion, non-adherence to treatment in the studied group of seniors with dementia correlates with the severity of cognitive impairment - a higher cognitive decline correlates with a higher risk of non-adherence to treatment.

  12. Pediatric digital chest imaging.

    PubMed

    Tarver, R D; Cohen, M; Broderick, N J; Conces, D J

    1990-01-01

    The Philips Computed Radiography system performs well with pediatric portable chest radiographs, handling the throughout of a busy intensive care service 24 hours a day. Images are excellent and routinely provide a conventional (unenhanced) image and an edge-enhanced image. Radiation dose is decreased by the lowered frequency of repeat examinations and the ability of the plates to respond to a much lower dose and still provide an adequate image. The high quality and uniform density of serial PCR portable radiographs greatly enhances diagnostic content of the films. Decreased resolution has not been a problem clinically. Image manipulation and electronic transfer to remote viewing stations appear to be helpful and are currently being evaluated further. The PCR system provides a marked improvement in pediatric portable chest radiology.

  13. Safety of ranibizumab in routine clinical practice: 1-year retrospective pooled analysis of four European neovascular AMD registries within the LUMINOUS programme

    PubMed Central

    Holz, Frank G; Bandello, Francesco; Gillies, Mark; Mitchell, Paul; Osborne, Aaron; Sheidow, Tom; Souied, Eric; Figueroa, Marta S

    2013-01-01

    Purpose Evaluation of 1-year safety profile of intravitreal ranibizumab 0.5 mg in neovascular age-related macular degeneration (NV-AMD) within routine clinical practice. Methods The LUMINOUS programme comprises a prospective observational study assessing ranibizumab ‘real-world’ safety and clinical effectiveness across licensed indications worldwide and an annual retrospective pooled safety analysis from completed NV-AMD ranibizumab registries. 1-year data from four European registries are available. This retrospective pooled safety analysis assessed 1-year incidence rates for safety events of particular interest (key ocular or systemic events possibly related to the injection procedure or vascular endothelial growth factor inhibition) together with treatment exposure. Patients were treated according to local protocols within the ranibizumab licence. Results Data of 4444 patients from registries in Germany (n=3470), the Netherlands (n=243), Belgium (n=260) and Sweden (n=471) were retrospectively pooled. Between 70.4% and 84.4% of enrolled patients completed 1 year of follow-up. Most frequent overall ocular events of particular interest were retinal pigment epithelial tears (27 patients; <1%) and intraocular pressure-related events (12 patients; <0.3%). Most frequent non-ocular event of particular interest was stroke (19 patients; 0.4%); annual incidence of stroke was low across all registries (0.0–0.5%). Conclusions Ranibizumab demonstrated favourable 1-year safety profile for NV-AMD in this routine clinical practice sample, consistent with previous reported trial data. Additional data from a larger patient population are needed to better describe the long-term safety profile of ranibizumab in routine clinical practice and further evaluate risk for infrequent but serious events in ‘real-life’ settings. The 5-year LUMINOUS prospective observational study will address this need. PMID:23850682

  14. Application of Digital Image Analysis to Determine Pancreatic Islet Mass and Purity in Clinical Islet Isolation and Transplantation

    PubMed Central

    Wang, Ling-jia; Kissler, Hermann J; Wang, Xiaojun; Cochet, Olivia; Krzystyniak, Adam; Misawa, Ryosuke; Golab, Karolina; Tibudan, Martin; Grzanka, Jakub; Savari, Omid; Grose, Randall; Kaufman, Dixon B; Millis, Michael; Witkowski, Piotr

    2015-01-01

    Pancreatic islet mass, represented by islet equivalent (IEQ), is the most important parameter in decision making for clinical islet transplantation. To obtain IEQ, the sample of islets is routinely counted manually under a microscope and discarded thereafter. Islet purity, another parameter in islet processing, is routinely acquired by estimation only. In this study, we validated our digital image analysis (DIA) system developed using the software of Image Pro Plus for islet mass and purity assessment. Application of the DIA allows to better comply with current good manufacturing practice (cGMP) standards. Human islet samples were captured as calibrated digital images for the permanent record. Five trained technicians participated in determination of IEQ and purity by manual counting method and DIA. IEQ count showed statistically significant correlations between the manual method and DIA in all sample comparisons (r >0.819 and p < 0.0001). Statistically significant difference in IEQ between both methods was found only in High purity 100μL sample group (p = 0.029). As far as purity determination, statistically significant differences between manual assessment and DIA measurement was found in High and Low purity 100μL samples (p<0.005), In addition, islet particle number (IPN) and the IEQ/IPN ratio did not differ statistically between manual counting method and DIA. In conclusion, the DIA used in this study is a reliable technique in determination of IEQ and purity. Islet sample preserved as a digital image and results produced by DIA can be permanently stored for verification, technical training and islet information exchange between different islet centers. Therefore, DIA complies better with cGMP requirements than the manual counting method. We propose DIA as a quality control tool to supplement the established standard manual method for islets counting and purity estimation. PMID:24806436

  15. Design of CT reconstruction kernel specifically for clinical lung imaging

    NASA Astrophysics Data System (ADS)

    Cody, Dianna D.; Hsieh, Jiang; Gladish, Gregory W.

    2005-04-01

    In this study we developed a new reconstruction kernel specifically for chest CT imaging. An experimental flat-panel CT scanner was used on large dogs to produce 'ground-truth" reference chest CT images. These dogs were also examined using a clinical 16-slice CT scanner. We concluded from the dog images acquired on the clinical scanner that the loss of subtle lung structures was due mostly to the presence of the background noise texture when using currently available reconstruction kernels. This qualitative evaluation of the dog CT images prompted the design of a new recon kernel. This new kernel consisted of the combination of a low-pass and a high-pass kernel to produce a new reconstruction kernel, called the 'Hybrid" kernel. The performance of this Hybrid kernel fell between the two kernels on which it was based, as expected. This Hybrid kernel was also applied to a set of 50 patient data sets; the analysis of these clinical images is underway. We are hopeful that this Hybrid kernel will produce clinical images with an acceptable tradeoff of lung detail, reliable HU, and image noise.

  16. Hounsfield unit recovery in clinical cone beam CT images of the thorax acquired for image guided radiation therapy

    NASA Astrophysics Data System (ADS)

    Slot Thing, Rune; Bernchou, Uffe; Mainegra-Hing, Ernesto; Hansen, Olfred; Brink, Carsten

    2016-08-01

    A comprehensive artefact correction method for clinical cone beam CT (CBCT) images acquired for image guided radiation therapy (IGRT) on a commercial system is presented. The method is demonstrated to reduce artefacts and recover CT-like Hounsfield units (HU) in reconstructed CBCT images of five lung cancer patients. Projection image based artefact corrections of image lag, detector scatter, body scatter and beam hardening are described and applied to CBCT images of five lung cancer patients. Image quality is evaluated through visual appearance of the reconstructed images, HU-correspondence with the planning CT images, and total volume HU error. Artefacts are reduced and CT-like HUs are recovered in the artefact corrected CBCT images. Visual inspection confirms that artefacts are indeed suppressed by the proposed method, and the HU root mean square difference between reconstructed CBCTs and the reference CT images are reduced by 31% when using the artefact corrections compared to the standard clinical CBCT reconstruction. A versatile artefact correction method for clinical CBCT images acquired for IGRT has been developed. HU values are recovered in the corrected CBCT images. The proposed method relies on post processing of clinical projection images, and does not require patient specific optimisation. It is thus a powerful tool for image quality improvement of large numbers of CBCT images.

  17. Social Withdrawal Among Individuals Receiving Psychiatric Care: Derivation of a Scale Using Routine Clinical Assessment Data to Support Screening and Outcome Measurement.

    PubMed

    Rios, Sebastian; Perlman, Christopher M

    2017-04-24

    Social withdrawal is a symptom experienced by individuals with an array of mental health conditions, particularly those with schizophrenia and mood disorders. Assessments of social withdrawal are often lengthy and may not be routinely integrated within the comprehensive clinical assessment of the individual. This study utilized item response and classical test theory methods to derive a Social Withdrawal Scale (SWS) using items embedded within a routine clinical assessment, the RAI-Mental Health (RAI-MH). Using data from 60,571 inpatients in Ontario, Canada, a common factor analysis identified seven items from the RAI-MH that measure social withdrawal. A graded response model found that six items had acceptable discrimination parameters: lack of motivation, reduced interaction, decreased energy, flat affect, anhedonia, and loss of interest. Summing these items, the SWS was found to have strong internal consistency (Cronbach's alpha = 0.82) and showed a medium to large effect size (d = 0.77) from admission to discharge. Fewer individuals with high SWS scores participated in social activity or reported having a confidant compared to those with lower scores. Since the RAI-MH is available across clinical subgroups in several jurisdictions, the SWS is a useful tool for screening, clinical decision support, and evaluation.

  18. Antiretroviral Simplification with Darunavir/Ritonavir Monotherapy in Routine Clinical Practice: Safety, Effectiveness, and Impact on Lipid Profile

    PubMed Central

    Santos, José R.; Moltó, José; Llibre, Josep M.; Negredo, Eugenia; Bravo, Isabel; Ornelas, Arelly; Clotet, Bonaventura; Paredes, Roger

    2012-01-01

    Background Simplification of antiretroviral treatment (ART) with darunavir/ritonavir (DRV/r) monotherapy has achieved sustained suppression of plasma viral load (pVL) in clinical trials; however, its effectiveness and safety profile has not been evaluated in routine clinical practice. Methodology/Principal Findings We performed a retrospective cohort analysis of HIV-1-infected patients who initiated DRV/r monotherapy once daily with a pVL <50 copies/mL under ART and at least 1 subsequent follow-up visit in our clinic. The primary study endpoints were the percentage of patients with virological failure (VF, defined as 2 consecutive pVL>50 copies/mL) at week 48, and time to VF. Other causes of treatment discontinuation and changes in lipid profile were evaluated up to week 48. Ninety-two patients were followed for a median (IQR) of 73 (57–92) weeks. The median baseline and nadir CD4+ T-cell counts were 604 (433–837) and 238 (150–376) cells/mm3, respectively. Patients had previously received a median of 5 (3–9) ART lines and maintained a pVL<50 copies/mL for a median of 76 (32–176) weeks before initiating DRV/r monotherapy. Nine (9.8%) patients developed VF at week 48; time to VF was 47.1 (IQR: 36.1–47.8) weeks among patients with VF. Other reasons for changing ART were gastrointestinal disturbances (n = 3), rash (n = 1), and impaired CD4 recovery (n = 2). Median low-density lipoprotein cholesterol levels increased from 116.1 mg/dL at baseline to 137.3 mg/dL at 48 weeks (p = 0.001). Conclusions/Significance Treatment simplification with DRV/r monotherapy seems safe and effective in routine clinical practice. Further research is needed to elucidate the effect of DRV/r monotherapy on cholesterol levels. PMID:22666357

  19. The use of laser Doppler imaging as an aid in clinical management decision making in the treatment of vesicant burns.

    PubMed

    Brown, R F; Rice, P; Bennett, N J

    1998-12-01

    Vesicants are a group of chemicals recognised, under the terms of the Chemical Weapons Convention, as potential chemical warfare agents whose prime effect on the skin is to cause burns and blistering. Experience of the clinical management of these injuries is not readily available and therefore an accurate assessment of the severity of the lesion and extent of tissue involvement is an important factor when determining the subsequent clinical management strategy for such lesions. This study was performed to assess the use of laser Doppler imaging (LDI) as a noninvasive means of assessing wound microvascular perfusion following challenge with the vesicant agents (sulphur mustard or lewisite) by comparing the images obtained with histopathological analysis of the lesion. Large white pigs were challenged with sulphur mustard (1.91 mg cm(-2)) or lewisite (0.3 mg.cm(-2)) vapour for periods of up to 6 h At intervals of between 1 h and 7 days following vesicant challenge, LDI images were acquired and samples for routine histopathology were taken. The results from this study suggest that LDI was: (i) a simple, reproducible and noninvasive means of assessing changes in tissue perfusion, and hence tissue viability, in developing and healing vesicant burns; (ii) the LDI images correlates well with histopathological assessment of the resulting lesions and the technique was sufficiently sensitive enough to discriminate between skin lesions of different aetiology. These attributes suggest that LDI would be a useful investigative tool that could aid clinical management decision making in the early treatment of vesicant agent-induced skin burns.

  20. The use of routine EEG in acute ischemic stroke patients without seizures: generalized but not focal EEG pathology is associated with clinical deterioration.

    PubMed

    Wolf, Marc E; Ebert, Anne D; Chatzikonstantinou, Anastasios

    2017-05-01

    Specialized electroencephalography (EEG) methods have been used to provide clues about stroke features and prognosis. However, the value of routine EEG in stroke patients without (suspected) seizures has been somewhat neglected. We aimed to assess this in a group of acute ischemic stroke patients in regard to short-term prognosis and basic stroke features. We assessed routine (10-20) EEG findings in 69 consecutive acute ischemic stroke patients without seizures. Associations between EEG abnormalities and NIHSS scores, clinical improvement or deterioration as well as MRI stroke characteristics were evaluated. Mean age was 69 ± 18 years, 43 of the patients (62.3%) were men. Abnormal EEG was found in 40 patients (58%) and was associated with higher age (p = 0.021). The most common EEG pathology was focal slowing (30; 43.5%). No epileptiform potentials were found. Abnormal EEG in general and generalized or focal slowing in particular was significantly associated with higher NIHSS score on admission and discharge as well as with hemorrhagic transformation of the ischemic lesion. Abnormal EEG and generalized (but not focal) slowing were associated with clinical deterioration ( p = 0.036, p = 0.003). Patients with lacunar strokes had no EEG abnormalities. Abnormal EEG in general and generalized slowing in particular are associated with clinical deterioration after acute ischemic stroke. The study demonstrates the value of routine EEG as a simple diagnostic tool in the evaluation of stroke patients especially with regard to short-term prognosis.

  1. The impact of introducing intensity modulated radiotherapy into routine clinical practice.

    PubMed

    Miles, Elizabeth A; Clark, Catharine H; Urbano, M Teresa Guerrero; Bidmead, Margaret; Dearnaley, David P; Harrington, Kevin J; A'Hern, Roger; Nutting, Christopher M

    2005-12-01

    Intensity modulated radiotherapy (IMRT) at the Royal Marsden Hospital London was introduced in July 2001. Treatment delivery was dynamic using a single-phase technique. Concerns were raised regarding increased clinical workload due to introduction of new technology. The potential increased use of resources was assessed. IMRT patient selection was within guidelines of clinical trials and included patients undergoing prostate plus pelvic lymph node (PPN) irradiation and head and neck cancer (HNC) treatment. Patient planning, quality assurance and treatment times were collected for an initial IMRT patient group. A comparative group of patients with advanced HNC undergoing two- or three-phase conventional radiotherapy, requiring matched photon and electron fields, were also timed. The median overall total planning time for IMRT was greater for HNC patients compared to the PPN cohort. For HNC the overall IMRT planning time was significantly longer than for conventional. The median treatment time for conventional two- or three-phase HNC treatments, encompassing similar volumes to those treated with IMRT, was greater than that for the IMRT HNC patient cohort. A reduction in radiographer man hours per patient of 4.8h was recorded whereas physics time was increased by 4.9h per patient. IMRT currently increases overall planning time. Additional clinician input is required for target volume localisation. Physics time is increased, a significant component of this being patient specific QA. Radiographer time is decreased. For HNC a single phase IMRT treatment has proven to be more efficient than a multiple phase conventional treatment. IMRT has been integrated smoothly and efficiently into the existing treatment working day. This preliminary study suggests that IMRT could be a routine treatment with efficient use of current radiotherapy resources.

  2. Knee arthroscopy routines and practice.

    PubMed

    Brattwall, M; Jacobson, E; Forssblad, M; Jakobsson, J

    2010-12-01

    Knee arthroscopy is one of most commonly performed day-case orthopaedic procedures, thus consuming huge medical resources. The aim of the present questionnaire survey was to study knee arthroscopy routines and practice. An electronic web-based survey including questions around pre-, per- and postoperative routines for elective knee arthroscopy was send to all orthopaedic units associated to the Swedish Arthroscopic Society (n = 60). Responses covering 37 centres out of 60 (response rate 62%) were returned. Preoperative radiograph routines varied considerable between centres; conventional radiograph varied between 5 and 100% and preoperative MRI between 5 and 80% of patients. General anaesthesia was the preferred intra-operative technique used in all centres (median 79% of patients), local anaesthesia with or without light sedation was used in all 28 out of the 37 centres responding (median 10% of cases) and spinal anaesthesia was used in 15 centres (median 5% of cases). Intra-articular local anaesthesia was provided in all but one of centres. Perioperative administration of oral NSAIDs was common (31 out 37), 6 centres (all teaching hospitals) did not routinely give pre- or postoperative NSAID. Analgesic prescription was provided on a regular base in 18 (49%) of centres; an NSAID being the most commonly prescribed. All but one centre provided written information and instruction at discharge. Referral to physiotherapy, prescribed sick leave and scheduled follow-up in the outpatient clinic diverged considerably. Routines and practice associated to elective knee arthroscopy differed; however, no clear differences in practice were seen between teaching centres, general or local hospitals apart from a lower usage of NSAID for perioperative analgesia. There is an obvious room for further standardisation in the routine handling of patients undergoing elective arthroscopy of the knee.

  3. The increasing influence of medical image processing in clinical neuroimaging.

    PubMed

    Barillot, Christian

    2007-01-20

    This paper review the evolution of clinical neuroinformatics domain in the passed and gives an outlook how this research field will evolve in clinical neurology (e.g. Epilepsy, Multiple Sclerosis, Dementia) and neurosurgery (e.g. image guided surgery, intra-operative imaging, the definition of the Operation Room of the future). These different issues, as addressed by the VisAGeS research team, are discussed in more details and the benefits of a close collaboration between clinical scientists (radiologist, neurologist and neurosurgeon) and computer scientists are shown to give adequate answers to the series of problems which needs to be solved for a more effective use of medical images in clinical neurosciences.

  4. The clinical impact of using complex molecular profiling strategies in routine oncology practice.

    PubMed

    Laes, Jean-François; Aftimos, Philippe; Barthelemy, Philippe; Bellmunt, Joaquim; Berchem, Guy; Camps, Carlos; Peñas, Ramón de Las; Finzel, Ana; García-Foncillas, Jesús; Hervonen, Petteri; Wahid, Ibrahim; Joensuu, Timo; Kathan, Louis; Kong, Anthony; Mackay, James; Mikropoulos, Christos; Mokbel, Kefah; Mouysset, Jean-Loup; Odarchenko, Sergey; Perren, Timothy J; Pienaar, Rika; Regonesi, Carlos; Alkhayyat, Shadi Salem; El Kinge, Abdul Rahman; Abulkhair, Omalkhair; Galal, Khaled Morsi; Ghanem, Hady; El Karak, Fadi; Garcia, Angel; Ghitti, Gregori; Sadik, Helen

    2018-04-17

    Molecular profiling and functional assessment of signalling pathways of advanced solid tumours are becoming increasingly available. However, their clinical utility in guiding patients' treatment remains unknown. Here, we assessed whether molecular profiling helps physicians in therapeutic decision making by analysing the molecular profiles of 1057 advanced cancer patient samples after failing at least one standard of care treatment using a combination of next-generation sequencing (NGS), immunohistochemistry (IHC) and other specific tests. The resulting information was interpreted and personalized treatments for each patient were suggested. Our data showed that NGS alone provided the oncologist with useful information in 10-50% of cases (depending on cancer type), whereas the addition of IHC/other tests increased extensively the usefulness of the information provided. Using internet surveys, we investigated how therapy recommendations influenced treatment choice of the oncologist. For patients who were still alive after the provision of the molecular information (76.8%), 60.4% of their oncologists followed report recommendations. Most treatment decisions (93.4%) were made based on the combination of NGS and IHC/other tests, and an approved drug- rather than clinical trial enrolment- was the main treatment choice. Most common reasons given by physicians to explain the non-adherence to recommendations were drug availability and cost, which remain barriers to personalised precision medicine. Finally, we observed that 27% of patients treated with the suggested therapies had an overall survival > 12 months. Our study demonstrates that the combination of NGS and IHC/other tests provides the most useful information in aiding treatment decisions by oncologists in routine clinical practice.

  5. Imaging and Data Acquisition in Clinical Trials for Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    FitzGerald, Thomas J., E-mail: Thomas.Fitzgerald@umassmed.edu; Bishop-Jodoin, Maryann; Followill, David S.

    2016-02-01

    Cancer treatment evolves through oncology clinical trials. Cancer trials are multimodal and complex. Assuring high-quality data are available to answer not only study objectives but also questions not anticipated at study initiation is the role of quality assurance. The National Cancer Institute reorganized its cancer clinical trials program in 2014. The National Clinical Trials Network (NCTN) was formed and within it was established a Diagnostic Imaging and Radiation Therapy Quality Assurance Organization. This organization is Imaging and Radiation Oncology Core, the Imaging and Radiation Oncology Core Group, consisting of 6 quality assurance centers that provide imaging and radiation therapy qualitymore » assurance for the NCTN. Sophisticated imaging is used for cancer diagnosis, treatment, and management as well as for image-driven technologies to plan and execute radiation treatment. Integration of imaging and radiation oncology data acquisition, review, management, and archive strategies are essential for trial compliance and future research. Lessons learned from previous trials are and provide evidence to support diagnostic imaging and radiation therapy data acquisition in NCTN trials.« less

  6. Should image rotation be addressed during routine cone-beam CT quality assurance?

    PubMed

    Ayan, Ahmet S; Lin, Haibo; Yeager, Caitlyn; Deville, Curtiland; McDonough, James; Zhu, Timothy C; Anderson, Nathan; Bar Ad, Voichita; Lu, Hsiao-Ming; Both, Stefan

    2013-02-21

    The purpose of this study is to investigate whether quality assurance (QA) for cone-beam computed tomography (CBCT) image rotation is necessary in order to ensure the accuracy of CBCT based image-guided radiation therapy (IGRT) and adaptive radiotherapy (ART). Misregistration of angular coordinates during CBCT acquisition may lead to a rotated reconstructed image. If target localization is performed based on this image, an under- or over-dosage of the target volume (TV) and organs at risk (OARs) may occur. Therefore, patient CT image sets were rotated by 1° up to 3° and the treatment plans were recalculated to quantify changes in dose-volume histograms. A computer code in C++ was written to model the TV displacement and overlap area of an ellipse shape at the target and dose prescription levels corresponding to the image rotation. We investigated clinical scenarios in IGRT and ART in order to study the implications of image rotation on dose distributions for: (1) lateral TV and isocenter (SBRT), (2) central TV and isocenter (IMRT), (3) lateral TV and isocenter (IMRT). Mathematical analysis showed the dose coverage of TV depends on its shape, size, location, and orientation relative to the isocenter. Evaluation of three first scenario for θ = 1° showed variations in TV D95 in the context of IGRT and ART when compared to the original plan were within 2.7 ± 2.6% and 7.7 ± 6.9% respectively while variations in the second and third scenarios were less significant (<0.5%) for the angular range evaluated. However a larger degree of variation was found in terms of minimum and maximum doses for target and OARs. The rotation of CBCT image data sets may have significant dosimetric consequences in IGRT and ART. The TV's location relative to isocenter and shape determine the extent of alterations in dose indicators. Our findings suggest that a CBCT QA criterion of 1° would be a reasonable action level to ensure accurate dose delivery.

  7. Should image rotation be addressed during routine cone-beam CT quality assurance?

    NASA Astrophysics Data System (ADS)

    Ayan, Ahmet S.; Lin, Haibo; Yeager, Caitlyn; Deville, Curtiland; McDonough, James; Zhu, Timothy C.; Anderson, Nathan; Bar Ad, Voichita; Lu, Hsiao-Ming; Both, Stefan

    2013-02-01

    The purpose of this study is to investigate whether quality assurance (QA) for cone-beam computed tomography (CBCT) image rotation is necessary in order to ensure the accuracy of CBCT based image-guided radiation therapy (IGRT) and adaptive radiotherapy (ART). Misregistration of angular coordinates during CBCT acquisition may lead to a rotated reconstructed image. If target localization is performed based on this image, an under- or over-dosage of the target volume (TV) and organs at risk (OARs) may occur. Therefore, patient CT image sets were rotated by 1° up to 3° and the treatment plans were recalculated to quantify changes in dose-volume histograms. A computer code in C++ was written to model the TV displacement and overlap area of an ellipse shape at the target and dose prescription levels corresponding to the image rotation. We investigated clinical scenarios in IGRT and ART in order to study the implications of image rotation on dose distributions for: (1) lateral TV and isocenter (SBRT), (2) central TV and isocenter (IMRT), (3) lateral TV and isocenter (IMRT). Mathematical analysis showed the dose coverage of TV depends on its shape, size, location, and orientation relative to the isocenter. Evaluation of three first scenario for θ = 1° showed variations in TV D95 in the context of IGRT and ART when compared to the original plan were within 2.7 ± 2.6% and 7.7 ± 6.9% respectively while variations in the second and third scenarios were less significant (<0.5%) for the angular range evaluated. However a larger degree of variation was found in terms of minimum and maximum doses for target and OARs. The rotation of CBCT image data sets may have significant dosimetric consequences in IGRT and ART. The TV's location relative to isocenter and shape determine the extent of alterations in dose indicators. Our findings suggest that a CBCT QA criterion of 1° would be a reasonable action level to ensure accurate dose delivery.

  8. Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system

    PubMed Central

    Li, Ye; Pang, Yong; Vigneron, Daniel; Glenn, Orit; Xu, Duan; Zhang, Xiaoliang

    2011-01-01

    Fetal MRI on 1.5T clinical scanner has been increasingly becoming a powerful imaging tool for studying fetal brain abnormalities in vivo. Due to limited availability of dedicated fetal phased arrays, commercial torso or cardiac phased arrays are routinely used for fetal scans, which are unable to provide optimized SNR and parallel imaging performance with a small number coil elements, and insufficient coverage and filling factor. This poses a demand for the investigation and development of dedicated and efficient radiofrequency (RF) hardware to improve fetal imaging. In this work, an investigational approach to simulate the performance of multichannel flexible phased arrays is proposed to find a better solution to fetal MR imaging. A 32 channel fetal array is presented to increase coil sensitivity, coverage and parallel imaging performance. The electromagnetic field distribution of each element of the fetal array is numerically simulated by using finite-difference time-domain (FDTD) method. The array performance, including B1 coverage, parallel reconstructed images and artifact power, is then theoretically calculated and compared with the torso array. Study results show that the proposed array is capable of increasing B1 field strength as well as sensitivity homogeneity in the entire area of uterus. This would ensure high quality imaging regardless of the location of the fetus in the uterus. In addition, the paralleling imaging performance of the proposed fetal array is validated by using artifact power comparison with torso array. These results demonstrate the feasibility of the 32 channel flexible array for fetal MR imaging at 1.5T. PMID:22408747

  9. Process mining routinely collected electronic health records to define real-life clinical pathways during chemotherapy.

    PubMed

    Baker, Karl; Dunwoodie, Elaine; Jones, Richard G; Newsham, Alex; Johnson, Owen; Price, Christopher P; Wolstenholme, Jane; Leal, Jose; McGinley, Patrick; Twelves, Chris; Hall, Geoff

    2017-07-01

    There is growing interest in the use of routinely collected electronic health records to enhance service delivery and facilitate clinical research. It should be possible to detect and measure patterns of care and use the data to monitor improvements but there are methodological and data quality challenges. Driven by the desire to model the impact of a patient self-test blood count monitoring service in patients on chemotherapy, we aimed to (i) establish reproducible methods of process-mining electronic health records, (ii) use the outputs derived to define and quantify patient pathways during chemotherapy, and (iii) to gather robust data which is structured to be able to inform a cost-effectiveness decision model of home monitoring of neutropenic status during chemotherapy. Electronic Health Records at a UK oncology centre were included if they had (i) a diagnosis of metastatic breast cancer and received adjuvant epirubicin and cyclosphosphamide chemotherapy or (ii) colorectal cancer and received palliative oxaliplatin and infusional 5-fluorouracil chemotherapy, and (iii) were first diagnosed with cancer between January 2004 and February 2013. Software and a Markov model were developed, producing a schematic of patient pathways during chemotherapy. Significant variance from the assumed care pathway was evident from the data. Of the 535 patients with breast cancer and 420 with colorectal cancer there were 474 and 329 pathway variants respectively. Only 27 (5%) and 26 (6%) completed the planned six cycles of chemotherapy without having unplanned hospital contact. Over the six cycles, 169 (31.6%) patients with breast cancer and 190 (45.2%) patients with colorectal cancer were admitted to hospital. The pathways of patients on chemotherapy are complex. An iterative approach to addressing semantic and data quality issues enabled the effective use of routinely collected patient records to produce accurate models of the real-life experiences of chemotherapy patients and

  10. Assessment of acquisition protocols for routine imaging of Y-90 using PET/CT

    PubMed Central

    2013-01-01

    Background Despite the early theoretical prediction of the 0+-0+ transition of 90Zr, 90Y-PET underwent only recently a growing interest for the development of imaging radioembolization of liver tumors. The aim of this work was to determine the minimum detectable activity (MDA) of 90Y by PET imaging and the impact of time-of-flight (TOF) reconstruction on detectability and quantitative accuracy according to the lesion size. Methods The study was conducted using a Siemens Biograph® mCT with a 22 cm large axial field of view. An IEC torso-shaped phantom containing five coplanar spheres was uniformly filled to achieve sphere-to-background ratios of 40:1. The phantom was imaged nine times in 14 days over 30 min. Sinograms were reconstructed with and without TOF information. A contrast-to-noise ratio (CNR) index was calculated using the Rose criterion, taking partial volume effects into account. The impact of reconstruction parameters on quantification accuracy, detectability, and spatial localization of the signal was investigated. Finally, six patients with hepatocellular carcinoma and four patients included in different 90Y-based radioimmunotherapy protocols were enrolled for the evaluation of the imaging parameters in a clinical situation. Results The highest CNR was achieved with one iteration for both TOF and non-TOF reconstructions. The MDA, however, was found to be lower with TOF than with non-TOF reconstruction. There was no gain by adding TOF information in terms of CNR for concentrations higher than 2 to 3 MBq mL−1, except for infra-centimetric lesions. Recovered activity was highly underestimated when a single iteration or non-TOF reconstruction was used (10% to 150% less depending on the lesion size). The MDA was estimated at 1 MBq mL−1 for a TOF reconstruction and infra-centimetric lesions. Images from patients treated with microspheres were clinically relevant, unlike those of patients who received systemic injections of 90Y. Conclusions Only

  11. Training clinicians in how to use patient-reported outcome measures in routine clinical practice.

    PubMed

    Santana, Maria J; Haverman, Lotte; Absolom, Kate; Takeuchi, Elena; Feeny, David; Grootenhuis, Martha; Velikova, Galina

    2015-07-01

    Patient-reported outcome measures (PROs) were originally developed for comparing groups of people in clinical trials and population studies, and the results were used to support treatment recommendations or inform health policy, but there was not direct benefit for the participants providing PROs data. However, as the experience in using those measures increased, it became obvious the clinical value in using individual patient PROs profiles in daily practice to identify/monitor symptoms, evaluate treatment outcomes and support shared decision-making. A key issue limiting successful implementation is clinicians' lack of knowledge on how to effectively utilize PROs data in their clinical encounters. Using a change management theoretical framework, this paper describes the development and implementation of three programs for training clinicians to effectively use PRO data in routine practice. The training programs are in three diverse clinical areas (adult oncology, lung transplant and paediatrics), in three countries with different healthcare systems, thus providing a rare opportunity to pull out common approaches whilst recognizing specific settings. For each program, we describe the clinical and organizational setting, the program planning and development, the content of the training session with supporting material, subsequent monitoring of PROs use and evidence of adoption. The common successful components and practical steps are identified, leading to discussion and future recommendations. The results of the three training programs are described as the implementation. In the oncology program, PRO data have been developed and are currently evaluated; in the lung transplant program, PRO data are used in daily practice and the integration with electronic patient records is under development; and in the paediatric program, PRO data are fully implemented with around 7,600 consultations since the start of the implementation. Adult learning programs teaching clinicians

  12. Effect of On-Demand vs Routine Nebulization of Acetylcysteine With Salbutamol on Ventilator-Free Days in Intensive Care Unit Patients Receiving Invasive Ventilation: A Randomized Clinical Trial.

    PubMed

    van Meenen, David M P; van der Hoeven, Sophia M; Binnekade, Jan M; de Borgie, Corianne A J M; Merkus, Maruschka P; Bosch, Frank H; Endeman, Henrik; Haringman, Jasper J; van der Meer, Nardo J M; Moeniralam, Hazra S; Slabbekoorn, Mathilde; Muller, Marcella C A; Stilma, Willemke; van Silfhout, Bart; Neto, Ary Serpa; Ter Haar, Hans F M; Van Vliet, Jan; Wijnhoven, Jan Willem; Horn, Janneke; Juffermans, Nicole P; Pelosi, Paolo; Gama de Abreu, Marcelo; Schultz, Marcus J; Paulus, Frederique

    2018-03-13

    It remains uncertain whether nebulization of mucolytics with bronchodilators should be applied for clinical indication or preventively in intensive care unit (ICU) patients receiving invasive ventilation. To determine if a strategy that uses nebulization for clinical indication (on-demand) is noninferior to one that uses preventive (routine) nebulization. Randomized clinical trial enrolling adult patients expected to need invasive ventilation for more than 24 hours at 7 ICUs in the Netherlands. On-demand nebulization of acetylcysteine or salbutamol (based on strict clinical indications, n = 471) or routine nebulization of acetylcysteine with salbutamol (every 6 hours until end of invasive ventilation, n = 473). The primary outcome was the number of ventilator-free days at day 28, with a noninferiority margin for a difference between groups of -0.5 days. Secondary outcomes included length of stay, mortality rates, occurrence of pulmonary complications, and adverse events. Nine hundred twenty-two patients (34% women; median age, 66 (interquartile range [IQR], 54-75 years) were enrolled and completed follow-up. At 28 days, patients in the on-demand group had a median 21 (IQR, 0-26) ventilator-free days, and patients in the routine group had a median 20 (IQR, 0-26) ventilator-free days (1-sided 95% CI, -0.00003 to ∞). There was no significant difference in length of stay or mortality, or in the proportion of patients developing pulmonary complications, between the 2 groups. Adverse events (13.8% vs 29.3%; difference, -15.5% [95% CI, -20.7% to -10.3%]; P < .001) were more frequent with routine nebulization and mainly related to tachyarrhythmia (12.5% vs 25.9%; difference, -13.4% [95% CI, -18.4% to -8.4%]; P < .001) and agitation (0.2% vs 4.3%; difference, -4.1% [95% CI, -5.9% to -2.2%]; P < .001). Among ICU patients receiving invasive ventilation who were expected to not be extubated within 24 hours, on-demand compared with routine nebulization of

  13. The factor structure and psychometric properties of the Clinical Outcomes in Routine Evaluation – Outcome Measure (CORE-OM) in Norwegian clinical and non-clinical samples

    PubMed Central

    2013-01-01

    Background The Clinical Outcomes in Routine Evaluation - Outcome Measure (CORE-OM) is a 34-item instrument developed to monitor clinically significant change in out-patients. The CORE-OM covers four domains: well-being, problems/symptoms, functioning and risk, and sums up in two total scores: the mean of All items, and the mean of All non-risk items. The aim of this study was to examine the psychometric properties of the Norwegian translation of the CORE-OM. Methods A clinical sample of 527 out-patients from North Norwegian specialist psychiatric services, and a non-clinical sample of 464 persons were obtained. The non-clinical sample was a convenience sample consisting of friends and family of health personnel, and of students of medicine and clinical psychology. Students also reported psychological stress. Exploratory factor analysis (EFA) was employed in half the clinical sample. Confirmatory (CFA) factor analyses modelling the theoretical sub-domains were performed in the remaining half of the clinical sample. Internal consistency, means, and gender and age differences were studied by comparing the clinical and non-clinical samples. Stability, effect of language (Norwegian versus English), and of psychological stress was studied in the sub-sample of students. Finally, cut-off scores were calculated, and distributions of scores were compared between clinical and non-clinical samples, and between students reporting stress or no stress. Results The results indicate that the CORE-OM both measures general (g) psychological distress and sub-domains, of which risk of harm separates most clearly from the g factor. Internal consistency, stability and cut-off scores compared well with the original English version. No, or only negligible, language effects were found. Gender differences were only found for the well-being domain in the non-clinical sample and for the risk domain in the clinical sample. Current patient status explained differences between clinical and non-clinical

  14. Granulomatous mastitis: changing clinical and imaging features with image-guided biopsy correlation.

    PubMed

    Handa, Priyanka; Leibman, A Jill; Sun, Derek; Abadi, Maria; Goldberg, Aryeh

    2014-10-01

    To review clinical presentation, revisit patient demographics and imaging findings in granulomatous mastitis and determine the optimal biopsy method for diagnosis. A retrospective study was performed to review the clinical presentation, imaging findings and biopsy methods in patients with granulomatous mastitis. Twenty-seven patients with pathology-proven granulomatous mastitis were included. The average age at presentation was 38.0 years (range, 21-73 years). Seven patients were between 48 and 73 years old. Twenty-four patients presented with symptoms and three patients were asymptomatic. Nineteen patients were imaged with mammography demonstrating mammographically occult lesions as the predominant finding. Twenty-six patients were imaged with ultrasound and the most common finding was a mass lesion. Pathological diagnosis was made by image-guided biopsy in 44 % of patients. The imaging features of granulomatous mastitis on mammography are infrequently described. Our study demonstrates that granulomatous mastitis can occur in postmenopausal or asymptomatic patients, although previously reported exclusively in young women with palpable findings. Presentation on mammography as calcifications requiring mammographically guided vacuum-assisted biopsy has not been previously described. The diagnosis of granulomatous mastitis can easily be made by image-guided biopsy and surgical excision should be reserved for definitive treatment. • Characterizes radiographic appearance of granulomatous mastitis in postmenopausal or asymptomatic patients. • Granulomatous mastitis can present exclusively as calcifications on mammography. • The diagnosis of granulomatous mastitis is made by image-guided biopsy techniques.

  15. High resolution multimodal clinical ophthalmic imaging system

    PubMed Central

    Mujat, Mircea; Ferguson, R. Daniel; Patel, Ankit H.; Iftimia, Nicusor; Lue, Niyom; Hammer, Daniel X.

    2010-01-01

    We developed a multimodal adaptive optics (AO) retinal imager which is the first to combine high performance AO-corrected scanning laser ophthalmoscopy (SLO) and swept source Fourier domain optical coherence tomography (SSOCT) imaging modes in a single compact clinical prototype platform. Such systems are becoming ever more essential to vision research and are expected to prove their clinical value for diagnosis of retinal diseases, including glaucoma, diabetic retinopathy (DR), age-related macular degeneration (AMD), and retinitis pigmentosa. The SSOCT channel operates at a wavelength of 1 µm for increased penetration and visualization of the choriocapillaris and choroid, sites of major disease activity for DR and wet AMD. This AO system is designed for use in clinical populations; a dual deformable mirror (DM) configuration allows simultaneous low- and high-order aberration correction over a large range of refractions and ocular media quality. The system also includes a wide field (33 deg.) line scanning ophthalmoscope (LSO) for initial screening, target identification, and global orientation, an integrated retinal tracker (RT) to stabilize the SLO, OCT, and LSO imaging fields in the presence of lateral eye motion, and a high-resolution LCD-based fixation target for presentation of visual cues. The system was tested in human subjects without retinal disease for performance optimization and validation. We were able to resolve and quantify cone photoreceptors across the macula to within ~0.5 deg (~100-150 µm) of the fovea, image and delineate ten retinal layers, and penetrate to resolve features deep into the choroid. The prototype presented here is the first of a new class of powerful flexible imaging platforms that will provide clinicians and researchers with high-resolution, high performance adaptive optics imaging to help guide therapies, develop new drugs, and improve patient outcomes. PMID:20589021

  16. Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions: Endorsed by the Chinese Society of Cardiology.

    PubMed

    Räber, Lorenz; Mintz, Gary S; Koskinas, Konstantinos C; Johnson, Thomas W; Holm, Niels R; Onuma, Yoshinubo; Radu, Maria D; Joner, Michael; Yu, Bo; Jia, Haibo; Menevau, Nicolas; de la Torre Hernandez, Jose M; Escaned, Javier; Hill, Jonathan; Prati, Francesco; Colombo, Antonio; di Mario, Carlo; Regar, Evelyn; Capodanno, Davide; Wijns, William; Byrne, Robert A; Guagliumi, Giulio

    2018-05-22

    This Consensus Document is the first of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The first document appraises the role of intracoronary imaging to guide percutaneous coronary interventions (PCIs) in clinical practice. Current evidence regarding the impact of intracoronary imaging guidance on cardiovascular outcomes is summarized, and patients or lesions most likely to derive clinical benefit from an imaging-guided intervention are identified. The relevance of the use of IVUS or OCT prior to PCI for optimizing stent sizing (stent length and diameter) and planning the procedural strategy is discussed. Regarding post-implantation imaging, the consensus group recommends key parameters that characterize an optimal PCI result and provides cut-offs to guide corrective measures and optimize the stenting result. Moreover, routine performance of intracoronary imaging in patients with stent failure (restenosis or stent thrombosis) is recommended. Finally, strengths and limitations of IVUS and OCT for guiding PCI and assessing stent failures and areas that warrant further research are critically discussed.

  17. Experimental/clinical evaluation of EIT image reconstruction with l1 data and image norms

    NASA Astrophysics Data System (ADS)

    Mamatjan, Yasin; Borsic, Andrea; Gürsoy, Doga; Adler, Andy

    2013-04-01

    Electrical impedance tomography (EIT) image reconstruction is ill-posed, and the spatial resolution of reconstructed images is low due to the diffuse propagation of current and limited number of independent measurements. Generally, image reconstruction is formulated using a regularized scheme in which l2 norms are preferred for both the data misfit and image prior terms due to computational convenience which result in smooth solutions. However, recent work on a Primal Dual-Interior Point Method (PDIPM) framework showed its effectiveness in dealing with the minimization problem. l1 norms on data and regularization terms in EIT image reconstruction address both problems of reconstruction with sharp edges and dealing with measurement errors. We aim for a clinical and experimental evaluation of the PDIPM method by selecting scenarios (human lung and dog breathing) with known electrode errors, which require a rigorous regularization and cause the failure of reconstructions with l2 norm. Results demonstrate the applicability of PDIPM algorithms, especially l1 data and regularization norms for clinical applications of EIT showing that l1 solution is not only more robust to measurement errors in clinical setting, but also provides high contrast resolution on organ boundaries.

  18. Lesson Unplanning: Toward Transforming Routine Tasks into Non-Routine Problems

    ERIC Educational Resources Information Center

    Beghetto, Ronald A.

    2017-01-01

    How might teachers transform routine tasks into non-routine ones? The purpose of this article is to address this question. The article opens with a discussion of why non-routine problems require creative and original thought. Specifically, I discuss how non-routine problems require students to confront uncertainty and how uncertainty can serve as…

  19. Detecting breast microcalcifications using super-resolution ultrasound imaging: a clinical study

    NASA Astrophysics Data System (ADS)

    Huang, Lianjie; Labyed, Yassin; Hanson, Kenneth; Sandoval, Daniel; Pohl, Jennifer; Williamson, Michael

    2013-03-01

    Imaging breast microcalcifications is crucial for early detection and diagnosis of breast cancer. It is challenging for current clinical ultrasound to image breast microcalcifications. However, new imaging techniques using data acquired with a synthetic-aperture ultrasound system have the potential to significantly improve ultrasound imaging. We recently developed a super-resolution ultrasound imaging method termed the phase-coherent multiple-signal classification (PC-MUSIC). This signal subspace method accounts for the phase response of transducer elements to improve image resolution. In this paper, we investigate the clinical feasibility of our super-resolution ultrasound imaging method for detecting breast microcalcifications. We use our custom-built, real-time synthetic-aperture ultrasound system to acquire breast ultrasound data for 40 patients whose mammograms show the presence of breast microcalcifications. We apply our super-resolution ultrasound imaging method to the patient data, and produce clear images of breast calcifications. Our super-resolution ultrasound PC-MUSIC imaging with synthetic-aperture ultrasound data can provide a new imaging modality for detecting breast microcalcifications in clinic without using ionizing radiation.

  20. An estimation of the clinical mastitis incidence per 100 cows per year based on routinely collected herd data.

    PubMed

    Santman-Berends, I M G A; Lam, T J G M; Keurentjes, J; van Schaik, G

    2015-10-01

    The aim of this study was to evaluate whether it was possible to (1) estimate the clinical mastitis incidence rate (CMI) for all Dutch dairy herds and (2) to detect farms with a high CMI based on routinely collected herd data. For this study, 240 dairy farms with a conventional milking system that participated in the milk recording program every 4 to 6 wk were randomly selected and agreed to participate. From the initial 240 herds, data of clinical mastitis (CM) registrations and routinely collected herd data of 227 herds were complete and could be used for analysis. Routinely collected herd data consisted of identification and registration records, antimicrobial usage, test-day records from the milk recording program, bulk tank milk (BTM) somatic cell count data and results of diagnostic tests on BTM samples. For each of the 227 herds, the CMI per 100 cows per year was calculated per quarter of the year and was combined with the available herd data. Two models were developed to predict the CMI for all dairy herds and to detect individual herds that belonged to the 25% herds with the highest CMI. Records of 156 (67%) herds were used for development of the models and the remaining 71 (33%) were used for validation. The model that estimated the CMI in all herds consisted of 11 explanatory variables. The observed and predicted averages of the validation herds were not significantly different. The model estimated a CMI per 100 cows per year of 32.5 cases (95% confidence interval=30.2-34.8), whereas the farmers registered 33.4 cases (95% confidence interval=29.5-37.4). The model that aimed at detecting individual herds with a high CMI contained 6 explanatory variables and could correctly classify 77% of all validation herds at the quarter-year level. The most important variables in the model were antibiotic usage for treating CM and BTM somatic cell count. In conclusion, models based on routinely collected herd data gave an accurate prediction of CMI for all Dutch dairy

  1. Novel Developments in Instrumentation for PET Imaging

    NASA Astrophysics Data System (ADS)

    Karp, Joel

    2013-04-01

    Advances in medical imaging, in particular positron emission tomography (PET), have been based on technical developments in physics and instrumentation that have common foundations with detection systems used in other fields of physics. New detector materials are used in PET systems that maximize efficiency, timing characteristics and robustness, and which lead to improved image quality and quantitative accuracy for clinical imaging. Time of flight (TOF) techniques are now routinely used in commercial PET scanners that combine physiological imaging with anatomical imaging provided by x-ray computed tomography. Using new solid-state photo-sensors instead of traditional photo-multiplier tubes makes it possible to combine PET with magnetic resonance imaging which is a significant technical challenge, but one that is creating new opportunities for both research and clinical applications. An overview of recent advances in instrumentation, such as TOF and PET/MR will be presented, along with examples of imaging studies to demonstrate the impact on patient care and basic research of diseases.

  2. [Big data from clinical routine].

    PubMed

    Mansmann, U

    2018-04-01

    Over the past 100 years, evidence-based medicine has undergone several fundamental changes. Through the field of physiology, medical doctors were introduced to the natural sciences. Since the late 1940s, randomized and epidemiological studies have come to provide the evidence for medical practice, which led to the emergence of clinical epidemiology as a new field in the medical sciences. Within the past few years, big data has become the driving force behind the vision for having a comprehensive set of health-related data which tracks individual healthcare histories and consequently that of large populations. The aim of this article is to discuss the implications of data-driven medicine, and to examine how it can find a place within clinical care. The EU-wide discussion on the development of data-driven medicine is presented. The following features and suggested actions were identified: harmonizing data formats, data processing and analysis, data exchange, related legal frameworks and ethical challenges. For the effective development of data-driven medicine, pilot projects need to be conducted to allow for open and transparent discussion on the advantages and challenges. The Federal Ministry of Education and Research ("Bundesministerium für Bildung und Forschung," BMBF) Arthromark project is an important example. Another example is the Medical Informatics Initiative of the BMBF. The digital revolution affects clinic practice. Data can be generated and stored in quantities that are almost unimaginable. It is possible to take advantage of this for development of a learning healthcare system if the principles of medical evidence generation are integrated into innovative IT-infrastructures and processes.

  3. Development and Validation of the Pediatric Diabetes Routines Questionnaire for Adolescents.

    PubMed

    Pierce, Jessica S; Jordan, Sara S; Arnau, Randolph C

    2018-04-06

    This study describes the development and psychometric evaluation of an adolescent self-report version of the Pediatric Diabetes Routines Questionnaire (PDRQ:A), a measure of diabetes-specific routines for youth with type 1 diabetes, and further validation of the parent-version (PDRQ:P) in an adolescent sample. Participants included 120 parent-adolescent dyads (ages 12-17) and an additional 24 parents who completed measures of diabetes-specific adolescent routines, general adolescent routines, diabetes self-care, and family support of youth diabetes care. The PDRQ:P/A demonstrated good internal consistency, test-retest reliability, and parent-child agreement, and adequate validity coefficients. Confirmatory factor analysis supported a one-factor model. Promising results were obtained. The PDRQ:P/A is a clinically feasible parent- and self-report measure that can provide valuable information regarding how frequently adolescents engage in their diabetes management tasks in a consistent manner. Addition of an adolescent report format will enhance the utility of the measure for clinical and research use.

  4. Next-generation sequencing strategies enable routine detection of balanced chromosome rearrangements for clinical diagnostics and genetic research.

    PubMed

    Talkowski, Michael E; Ernst, Carl; Heilbut, Adrian; Chiang, Colby; Hanscom, Carrie; Lindgren, Amelia; Kirby, Andrew; Liu, Shangtao; Muddukrishna, Bhavana; Ohsumi, Toshiro K; Shen, Yiping; Borowsky, Mark; Daly, Mark J; Morton, Cynthia C; Gusella, James F

    2011-04-08

    The contribution of balanced chromosomal rearrangements to complex disorders remains unclear because they are not detected routinely by genome-wide microarrays and clinical localization is imprecise. Failure to consider these events bypasses a potentially powerful complement to single nucleotide polymorphism and copy-number association approaches to complex disorders, where much of the heritability remains unexplained. To capitalize on this genetic resource, we have applied optimized sequencing and analysis strategies to test whether these potentially high-impact variants can be mapped at reasonable cost and throughput. By using a whole-genome multiplexing strategy, rearrangement breakpoints could be delineated at a fraction of the cost of standard sequencing. For rearrangements already mapped regionally by karyotyping and fluorescence in situ hybridization, a targeted approach enabled capture and sequencing of multiple breakpoints simultaneously. Importantly, this strategy permitted capture and unique alignment of up to 97% of repeat-masked sequences in the targeted regions. Genome-wide analyses estimate that only 3.7% of bases should be routinely omitted from genomic DNA capture experiments. Illustrating the power of these approaches, the rearrangement breakpoints were rapidly defined to base pair resolution and revealed unexpected sequence complexity, such as co-occurrence of inversion and translocation as an underlying feature of karyotypically balanced alterations. These findings have implications ranging from genome annotation to de novo assemblies and could enable sequencing screens for structural variations at a cost comparable to that of microarrays in standard clinical practice. Copyright © 2011 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  5. Practical issues in implementing whole-genome-sequencing in routine diagnostic microbiology.

    PubMed

    Rossen, J W A; Friedrich, A W; Moran-Gilad, J

    2018-04-01

    Next generation sequencing (NGS) is increasingly being used in clinical microbiology. Like every new technology adopted in microbiology, the integration of NGS into clinical and routine workflows must be carefully managed. To review the practical aspects of implementing bacterial whole genome sequencing (WGS) in routine diagnostic laboratories. Review of the literature and expert opinion. In this review, we discuss when and how to integrate whole genome sequencing (WGS) in the routine workflow of the clinical laboratory. In addition, as the microbiology laboratories have to adhere to various national and international regulations and criteria for their accreditation, we deliberate on quality control issues for using WGS in microbiology, including the importance of proficiency testing. Furthermore, the current and future place of this technology in the diagnostic hierarchy of microbiology is described as well as the necessity of maintaining backwards compatibility with already established methods. Finally, we speculate on the question of whether WGS can entirely replace routine microbiology in the future and the tension between the fact that most sequencers are designed to process multiple samples in parallel whereas for optimal diagnosis a one-by-one processing of the samples is preferred. Special reference is made to the cost and turnaround time of WGS in diagnostic laboratories. Further development is required to improve the workflow for WGS, in particular to shorten the turnaround time, reduce costs, and streamline downstream data analyses. Only when these processes reach maturity will reliance on WGS for routine patient management and infection control management become feasible, enabling the transformation of clinical microbiology into a genome-based and personalized diagnostic field. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  6. Advanced endoscopic imaging in gastric neoplasia and preneoplasia

    PubMed Central

    Lee, Jonathan W J; Lim, Lee Guan; Yeoh, Khay Guan

    2017-01-01

    Conventional white light endoscopy remains the current standard in routine clinical practice for early detection of gastric cancer. However, it may not accurately diagnose preneoplastic gastric lesions. The technological advancements in the field of endoscopic imaging for gastric lesions are fast growing. This article reviews currently available advanced endoscopic imaging modalities, in particular chromoendoscopy, narrow band imaging and confocal laser endomicroscopy, and their corresponding evidence shown to improve diagnosis of preneoplastic gastric lesions. Raman spectrometry and polarimetry are also introduced as promising emerging technologies. PMID:28176895

  7. Electronic workflow for imaging in clinical research.

    PubMed

    Hedges, Rebecca A; Goodman, Danielle; Sachs, Peter B

    2014-08-01

    In the transition from paper to electronic workflow, the University of Colorado Health System's implementation of a new electronic health record system (EHR) forced all clinical groups to reevaluate their practices including the infrastructure surrounding clinical trials. Radiological imaging is an important piece of many clinical trials and requires a high level of consistency and standardization. With EHR implementation, paper orders were manually transcribed into the EHR, digitizing an inefficient work flow. A team of schedulers, radiologists, technologists, research personnel, and EHR analysts worked together to optimize the EHR to accommodate the needs of research imaging protocols. The transition to electronic workflow posed several problems: (1) there needed to be effective communication throughout the imaging process from scheduling to radiologist interpretation. (2) The exam ordering process needed to be automated to allow scheduling of specific research studies on specific equipment. (3) The billing process needed to be controlled to accommodate radiologists already supported by grants. (4) There needed to be functionality allowing exams to finalize automatically skipping the PACS and interpretation process. (5) There needed to be a way to alert radiologists that a specialized research interpretation was needed on a given exam. These issues were resolved through the optimization of the "visit type," allowing a high-level control of an exam at the time of scheduling. Additionally, we added columns and fields to work queues displaying grant identification numbers. The build solutions we implemented reduced the mistakes made and increased imaging quality and compliance.

  8. An experimental clinical evaluation of EIT imaging with ℓ1 data and image norms.

    PubMed

    Mamatjan, Yasin; Borsic, Andrea; Gürsoy, Doga; Adler, Andy

    2013-09-01

    Electrical impedance tomography (EIT) produces an image of internal conductivity distributions in a body from current injection and electrical measurements at surface electrodes. Typically, image reconstruction is formulated using regularized schemes in which ℓ2-norms are used for both data misfit and image prior terms. Such a formulation is computationally convenient, but favours smooth conductivity solutions and is sensitive to outliers. Recent studies highlighted the potential of ℓ1-norm and provided the mathematical basis to improve image quality and robustness of the images to data outliers. In this paper, we (i) extended a primal-dual interior point method (PDIPM) algorithm to 2.5D EIT image reconstruction to solve ℓ1 and mixed ℓ1/ℓ2 formulations efficiently, (ii) evaluated the formulation on clinical and experimental data, and (iii) developed a practical strategy to select hyperparameters using the L-curve which requires minimum user-dependence. The PDIPM algorithm was evaluated using clinical and experimental scenarios on human lung and dog breathing with known electrode errors, which requires a rigorous regularization and causes the failure of reconstruction with an ℓ2-norm solution. The results showed that an ℓ1 solution is not only more robust to unavoidable measurement errors in a clinical setting, but it also provides high contrast resolution on organ boundaries.

  9. A clinical perspective on the 2016 WHO brain tumor classification and routine molecular diagnostics.

    PubMed

    van den Bent, Martin J; Weller, Michael; Wen, Patrick Y; Kros, Johan M; Aldape, Ken; Chang, Susan

    2017-05-01

    The 2007 World Health Organization (WHO) classification of brain tumors did not use molecular abnormalities as diagnostic criteria. Studies have shown that genotyping allows a better prognostic classification of diffuse glioma with improved treatment selection. This has resulted in a major revision of the WHO classification, which is now for adult diffuse glioma centered around isocitrate dehydrogenase (IDH) and 1p/19q diagnostics. This revised classification is reviewed with a focus on adult brain tumors, and includes a recommendation of genes of which routine testing is clinically useful. Apart from assessment of IDH mutational status including sequencing of R132H-immunohistochemistry negative cases and testing for 1p/19q, several other markers can be considered for routine testing, including assessment of copy number alterations of chromosome 7 and 10 and of TERT promoter, BRAF, and H3F3A mutations. For "glioblastoma, IDH mutated" the term "astrocytoma grade IV" could be considered. It should be considered to treat IDH wild-type grades II and III diffuse glioma with polysomy of chromosome 7 and loss of 10q as glioblastoma. New developments must be more quickly translated into further revised diagnostic categories. Quality control and rapid integration of molecular findings into the final diagnosis and the communication of the final diagnosis to clinicians require systematic attention. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Systematic Reviews Published in Emergency Medicine Journals Do Not Routinely Search Clinical Trials Registries: A Cross-Sectional Analysis.

    PubMed

    Keil, Lukas G; Platts-Mills, Timothy F; Jones, Christopher W

    2015-10-01

    Publication bias compromises the validity of systematic reviews. This problem can be addressed in part through searching clinical trials registries to identify unpublished studies. This study aims to determine how often systematic reviews published in emergency medicine journals include clinical trials registry searches. We identified all systematic reviews published in the 6 highest-impact emergency medicine journals between January 1 and December 31, 2013. Systematic reviews that assessed the effects of an intervention were further examined to determine whether the authors described searching a clinical trials registry and whether this search identified relevant unpublished studies. Of 191 articles identified through PubMed search, 80 were confirmed to be systematic reviews. Our sample consisted of 41 systematic reviews that assessed a specific intervention. Eight of these 41 (20%) searched a clinical trials registry. For 4 of these 8 reviews, the registry search identified at least 1 relevant unpublished study. Systematic reviews published in emergency medicine journals do not routinely include searches of clinical trials registries. By helping authors identify unpublished trial data, the addition of registry searches may improve the validity of systematic reviews. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  11. Image analysis library software development

    NASA Technical Reports Server (NTRS)

    Guseman, L. F., Jr.; Bryant, J.

    1977-01-01

    The Image Analysis Library consists of a collection of general purpose mathematical/statistical routines and special purpose data analysis/pattern recognition routines basic to the development of image analysis techniques for support of current and future Earth Resources Programs. Work was done to provide a collection of computer routines and associated documentation which form a part of the Image Analysis Library.

  12. "There are too many, but never enough": qualitative case study investigating routine coding of clinical information in depression.

    PubMed

    Cresswell, Kathrin; Morrison, Zoe; Kalra, Dipak; Sheikh, Aziz

    2012-01-01

    We sought to understand how clinical information relating to the management of depression is routinely coded in different clinical settings and the perspectives of and implications for different stakeholders with a view to understanding how these may be aligned. Qualitative investigation exploring the views of a purposefully selected range of healthcare professionals, managers, and clinical coders spanning primary and secondary care. Our dataset comprised 28 semi-structured interviews, a focus group, documents relating to clinical coding standards and participant observation of clinical coding activities. We identified a range of approaches to coding clinical information including templates and order entry systems. The challenges inherent in clearly establishing a diagnosis, identifying appropriate clinical codes and possible implications of diagnoses for patients were particularly prominent in primary care. Although a range of managerial and research benefits were identified, there were no direct benefits from coded clinical data for patients or professionals. Secondary care staff emphasized the role of clinical coders in ensuring data quality, which was at odds with the policy drive to increase real-time clinical coding. There was overall no evidence of clear-cut direct patient care benefits to inform immediate care decisions, even in primary care where data on patients with depression were more extensively coded. A number of important secondary uses were recognized by healthcare staff, but the coding of clinical data to serve these ends was often poorly aligned with clinical practice and patient-centered considerations. The current international drive to encourage clinical coding by healthcare professionals during the clinical encounter may need to be critically examined.

  13. Pharmacovigilance during ibrutinib therapy for chronic lymphocytic leukemia (CLL)/small lymphocytic lymphoma (SLL) in routine clinical practice.

    PubMed

    Finnes, Heidi D; Chaffee, Kari G; Call, Timothy G; Ding, Wei; Kenderian, Saad S; Bowen, Deborah A; Conte, Michael; McCullough, Kristen B; Merten, Julianna A; Bartoo, Gabriel T; Smith, Matthew D; Leis, Jose; Chanan-Khan, Asher; Schwager, Susan M; Slager, Susan L; Kay, Neil E; Shanafelt, Tait D; Parikh, Sameer A

    2017-06-01

    Due to Cytochrome P450 3A (CYP3A) metabolism, clinical trials of ibrutinib-treated chronic lymphocytic leukemia (CLL) patients prohibited concurrent medications metabolized by CYP3A. We evaluated concomitant medication use in 118 ibrutinib-treated CLL patients outside the context of clinical trials. Seventy-five (64%) patients were on medications that could increase ibrutinib toxicity and 4 (3%) were on drugs that could decrease ibrutinib efficacy. Nineteen (16%) patients were on concomitant CYP3A inhibitors (11 moderate, 8 strong), and 4 (3%) were on CYP3A inducers (two patients were on both CYP3A inhibitors and inducers). Although the ibrutinib starting dose was changed in 18 patients on CYP3A interacting medications, no difference in 18-month progression-free survival or rate of ibrutinib discontinuation was observed in patients who were not. In routine clinical practice, 2 of 3 CLL patients commencing ibrutinib are on a concomitant medication with potential to influence ibrutinib metabolism. Formal medication review by a pharmacist should be considered in all patients initiating ibrutinib.

  14. No Value for Routine Chest Radiography in the Work-Up of Early Stage Cervical Cancer Patients

    PubMed Central

    Hoogendam, Jacob P.; Zweemer, Ronald P.; Verkooijen, Helena M.; de Jong, Pim A.; van den Bosch, Maurice A. A. J.; Verheijen, René H. M.; Veldhuis, Wouter B.

    2015-01-01

    Aim Evidence supporting the recommendation to include chest radiography in the work-up of all cervical cancer patients is limited. We investigated the diagnostic value of routine chest radiography in cervical cancer staging. Methods All consecutive cervical cancer patients who presented at our tertiary referral center in the Netherlands (January 2006 – September 2013), and for whom ≥6 months follow-up was available, were included. As part of the staging procedure, patients underwent a routine two-directional digital chest radiograph. Findings were compared to a composite reference standard consisting of all imaging studies and histology obtained during the 6 months following radiography. Results Of the 402 women who presented with cervical cancer, 288 (71.6%) underwent chest radiography and had ≥6 months follow-up. Early clinical stage (I/II) cervical cancer was present in 244/288 (84.7%) women, while 44 (15.3%) presented with advanced disease (stage III/IV). The chest radiograph of 1 woman – with advanced pre-radiograph stage (IVA) disease – showed findings consistent with pulmonary metastases. Radiographs of 7 other women – 4 early, 3 advanced stage disease – were suspicious for pulmonary metastases which was confirmed by additional imaging in only 1 woman (with pre-radiograph advanced stage (IIIB) disease) and excluded in 6 cases, including all women with early stage disease. In none of the 288 women were thoracic skeletal metastases identified on imaging or during 6 months follow up. Radiography was unremarkable in 76.4% of the study population, and showed findings unrelated to the cervical carcinoma in 21.2%. Conclusion Routine chest radiography was of no value for any of the early stage cervical cancer patients presenting at our tertiary center over a period of 7.7 years. PMID:26135733

  15. No Value for Routine Chest Radiography in the Work-Up of Early Stage Cervical Cancer Patients.

    PubMed

    Hoogendam, Jacob P; Zweemer, Ronald P; Verkooijen, Helena M; de Jong, Pim A; van den Bosch, Maurice A A J; Verheijen, René H M; Veldhuis, Wouter B

    2015-01-01

    Evidence supporting the recommendation to include chest radiography in the work-up of all cervical cancer patients is limited. We investigated the diagnostic value of routine chest radiography in cervical cancer staging. All consecutive cervical cancer patients who presented at our tertiary referral center in the Netherlands (January 2006 - September 2013), and for whom ≥6 months follow-up was available, were included. As part of the staging procedure, patients underwent a routine two-directional digital chest radiograph. Findings were compared to a composite reference standard consisting of all imaging studies and histology obtained during the 6 months following radiography. Of the 402 women who presented with cervical cancer, 288 (71.6%) underwent chest radiography and had ≥6 months follow-up. Early clinical stage (I/II) cervical cancer was present in 244/288 (84.7%) women, while 44 (15.3%) presented with advanced disease (stage III/IV). The chest radiograph of 1 woman - with advanced pre-radiograph stage (IVA) disease - showed findings consistent with pulmonary metastases. Radiographs of 7 other women - 4 early, 3 advanced stage disease - were suspicious for pulmonary metastases which was confirmed by additional imaging in only 1 woman (with pre-radiograph advanced stage (IIIB) disease) and excluded in 6 cases, including all women with early stage disease. In none of the 288 women were thoracic skeletal metastases identified on imaging or during 6 months follow up. Radiography was unremarkable in 76.4% of the study population, and showed findings unrelated to the cervical carcinoma in 21.2%. Routine chest radiography was of no value for any of the early stage cervical cancer patients presenting at our tertiary center over a period of 7.7 years.

  16. [Imaging center - optimization of the imaging process].

    PubMed

    Busch, H-P

    2013-04-01

    Hospitals around the world are under increasing pressure to optimize the economic efficiency of treatment processes. Imaging is responsible for a great part of the success but also of the costs of treatment. In routine work an excessive supply of imaging methods leads to an "as well as" strategy up to the limit of the capacity without critical reflection. Exams that have no predictable influence on the clinical outcome are an unjustified burden for the patient. They are useless and threaten the financial situation and existence of the hospital. In recent years the focus of process optimization was exclusively on the quality and efficiency of performed single examinations. In the future critical discussion of the effectiveness of single exams in relation to the clinical outcome will be more important. Unnecessary exams can be avoided, only if in addition to the optimization of single exams (efficiency) there is an optimization strategy for the total imaging process (efficiency and effectiveness). This requires a new definition of processes (Imaging Pathway), new structures for organization (Imaging Center) and a new kind of thinking on the part of the medical staff. Motivation has to be changed from gratification of performed exams to gratification of process quality (medical quality, service quality, economics), including the avoidance of additional (unnecessary) exams. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Quantitative imaging biomarkers: the application of advanced image processing and analysis to clinical and preclinical decision making.

    PubMed

    Prescott, Jeffrey William

    2013-02-01

    The importance of medical imaging for clinical decision making has been steadily increasing over the last four decades. Recently, there has also been an emphasis on medical imaging for preclinical decision making, i.e., for use in pharamaceutical and medical device development. There is also a drive towards quantification of imaging findings by using quantitative imaging biomarkers, which can improve sensitivity, specificity, accuracy and reproducibility of imaged characteristics used for diagnostic and therapeutic decisions. An important component of the discovery, characterization, validation and application of quantitative imaging biomarkers is the extraction of information and meaning from images through image processing and subsequent analysis. However, many advanced image processing and analysis methods are not applied directly to questions of clinical interest, i.e., for diagnostic and therapeutic decision making, which is a consideration that should be closely linked to the development of such algorithms. This article is meant to address these concerns. First, quantitative imaging biomarkers are introduced by providing definitions and concepts. Then, potential applications of advanced image processing and analysis to areas of quantitative imaging biomarker research are described; specifically, research into osteoarthritis (OA), Alzheimer's disease (AD) and cancer is presented. Then, challenges in quantitative imaging biomarker research are discussed. Finally, a conceptual framework for integrating clinical and preclinical considerations into the development of quantitative imaging biomarkers and their computer-assisted methods of extraction is presented.

  18. Brief sexual histories and routine HIV/STD testing by medical providers.

    PubMed

    Lanier, Yzette; Castellanos, Ted; Barrow, Roxanne Y; Jordan, Wilbert C; Caine, Virginia; Sutton, Madeline Y

    2014-03-01

    Clinicians who routinely take patient sexual histories have the opportunity to assess patient risk for sexually transmitted diseases (STDs), including human immunodeficiency virus (HIV), and make appropriate recommendations for routine HIV/STD screenings. However, less than 40% of providers conduct sexual histories with patients, and many do not receive formal sexual history training in school. After partnering with a national professional organization of physicians, we trained 26 (US and US territory-based) practicing physicians (58% female; median age=48 years) regarding sexual history taking using both in-person and webinar methods. Trainings occurred during either a 6-h onsite or 2-h webinar session. We evaluated their post-training experiences integrating sexual histories during routine medical visits. We assessed use of sexual histories and routine HIV/STD screenings. All participating physicians reported improved sexual history taking and increases in documented sexual histories and routine HIV/STD screenings. Four themes emerged from the qualitative evaluations: (1) the need for more sexual history training; (2) the importance of providing a gender-neutral sexual history tool; (3) the existence of barriers to routine sexual histories/testing; and (4) unintended benefits for providers who were conducting routine sexual histories. These findings were used to develop a brief, gender-neutral sexual history tool for clinical use. This pilot evaluation demonstrates that providers were willing to utilize a sexual history tool in clinical practice in support of HIV/STD prevention efforts.

  19. Brief Sexual Histories and Routine HIV/STD Testing by Medical Providers

    PubMed Central

    Lanier, Yzette; Castellanos, Ted; Barrow, Roxanne Y.; Jordan, Wilbert C.; Caine, Virginia

    2014-01-01

    Abstract Clinicians who routinely take patient sexual histories have the opportunity to assess patient risk for sexually transmitted diseases (STDs), including human immunodeficiency virus (HIV), and make appropriate recommendations for routine HIV/STD screenings. However, less than 40% of providers conduct sexual histories with patients, and many do not receive formal sexual history training in school. After partnering with a national professional organization of physicians, we trained 26 (US and US territory-based) practicing physicians (58% female; median age=48 years) regarding sexual history taking using both in-person and webinar methods. Trainings occurred during either a 6-h onsite or 2-h webinar session. We evaluated their post-training experiences integrating sexual histories during routine medical visits. We assessed use of sexual histories and routine HIV/STD screenings. All participating physicians reported improved sexual history taking and increases in documented sexual histories and routine HIV/STD screenings. Four themes emerged from the qualitative evaluations: (1) the need for more sexual history training; (2) the importance of providing a gender-neutral sexual history tool; (3) the existence of barriers to routine sexual histories/testing; and (4) unintended benefits for providers who were conducting routine sexual histories. These findings were used to develop a brief, gender-neutral sexual history tool for clinical use. This pilot evaluation demonstrates that providers were willing to utilize a sexual history tool in clinical practice in support of HIV/STD prevention efforts. PMID:24564387

  20. Stakeholders' views on the routine use of n-of-1 trials to improve clinical care and to make resource allocation decisions for drug use.

    PubMed

    Nikles, Jane; Mitchell, Geoffrey K; Clavarino, Alexandra; Yelland, Michael J; Del Mar, Christopher B

    2010-03-01

    N-of-1 trials are empirical formal tests using a within-patient randomised, double-blind, cross-over comparison of drug and placebo (or another drug), which we adapted to study individual patients' responses as a clinical tool to guide clinical management. We administered semi-structured interviews to gauge stakeholder perspectives on the possibility of using routine n-of-1 trials for this purpose. Stakeholders included government and non-government health care sector, and patient, clinician and consumer, organisations. Stakeholders supported more widespread implementation of n-of-1 trials, in a targeted fashion, with some caveats. Barriers to their widespread implementation included constraints on doctors' time, doctors' acceptance, drug company acceptance, patient willingness, and cost. Strategies for overcoming barriers included conditional Pharmaceutical Benefits Scheme listing if cost-effective. There was little consensus on which model of n-of-1 trial implementation would be most effective. We discuss different approaches to addressing the several concerns raised to enable widespread introduction of n-of-1 trials into routine clinical practice as a decision tool.

  1. Radically Reducing Radiation Exposure during Routine Medical Imaging

    Cancer.gov

    Exposure to radiation from medical imaging in the United States has increased dramatically. NCI and several partner organizations sponsored a 2011 summit to promote efforts to reduce radiation exposure from medical imaging.

  2. Chapter IX. Bedtime Routines in Toddlerhood: Prevalence, Consistency, and Associations with Nighttime Sleep

    PubMed Central

    Staples, Angela D.; Bates, John E.; Petersen, Isaac T.

    2016-01-01

    The ability to transition from wakefulness to sleep is one of the most important tasks in the development of sleep during early childhood. Although establishing regular bedtime routines for children with sleep problems can be clinically effective in reducing the number of signaled night awakenings and increasing amounts of sleep, it is unclear whether a regular bedtime routine would be associated with either the frequency of signaled night awakenings or nightly sleep minutes in a non-clinical sample of children. This study examined the role of a regular bedtime routine on the development of sleep regulation and consolidation in a community sample of young children. Adherence to a bedtime routine was concurrently associated with a greater amount of nightly sleep at 36 and 42 months. In addition, adherence to a bedtime routine predicted an increase in nightly sleep minutes over a six-month period. Finally, this study demonstrated that adherence to a bedtime routine was particularly supportive of developmental gains for children of mothers who used consistent parenting practices during the day. PMID:25704740

  3. Absence of Decline of Kidney Function in Human Immunodeficiency Virus-Infected Patients Under Routine Clinical Management.

    PubMed

    Boucquemont, Julie; Lawson-Ayayi, Sylvie; Rigothier, Claire; Bonnet, Fabrice; Proust-Lima, Cécile; Neau, Didier; Greib, Carine; Miremont-Salamé, Ghada; Dabis, François; Dupon, Michel; Dauchy, Frédéric-Antoine

    2017-01-01

    Since the introduction of antiretroviral therapy (ART), human immunodeficiency virus (HIV)-infected patients have a drastically improved prognosis but at the same time they are also more affected by non-HIV related complications, such as chronic kidney disease. The objective of our study was to investigate the effect of proteinuria and tenofovir (TDF)-containing ART regimens on the temporal evolution of estimated glomerular filtration rate (eGFR). Between April 2008 and October 2012, we enrolled 395 patients with a complete renal evaluation among patients from the ANRS C03 Aquitaine cohort, a prospective hospital-based cohort of HIV-1-infected patients under routine clinical management in southwestern France. eGFR was estimated at each patient follow-up visit. A linear mixed model was used to analyze eGFR dynamics, accounting for change in TDF by modeling eGFR trajectory according to treatment periods. At inclusion, 56.7% of patients were treated with TDF-containing ART regimens; prevalence of glomerular and tubular proteinuria was 7.9 and 10.8% respectively. A 1-year increase of cumulative exposure to TDF was significantly associated with a mean eGFR decrease of 1.27 mL/min/1.73 m2 (95% CI [-2.14 to -0.41]). Only a urine protein to creatinine ratio >100 mg/mmol and/or a urine albumin to creatinine ratio >70 mg/mmol were associated with eGFR trajectory (mean slope 6.18 mL/min/1.73 m2 per year; 95% CI [2.71 to 9.65]), whereas TDF use was not associated with such eGFR temporal evolution. Decline in kidney function is limited under routine clinical management with monitoring of renal function and interventions including decision to continue or discontinue TDF. © 2017 S. Karger AG, Basel.

  4. Developing everyday routines.

    PubMed

    McNamara, Paula; Humphry, Ruth

    2008-05-01

    This study obtains a deeper understanding of the processes supporting the formation of young children's routines in a child care classroom. Eight infants and toddlers and their teachers from two child care classrooms were observed for 4 to 6 months during periods of regularly occurring activities. Detailed, moment-to-moment descriptions of their behaviors and interactions were analyzed. Eleven processes supported the development of children's routines. Teachers structured and guided the children's experiences in learning routines, and children initiated requests to do routines. The study also identified three processes where children invited, coached, and modeled, supporting one another in learning routines. Finally, familiar objects used in routines elicited the children's engagement.

  5. Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

    PubMed

    Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R

    2013-07-01

    The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson's correlation coefficient. Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, p<0.033) and eDE (R=0.77, p<0.008) were observed. Medical physics experts may use the physical image quality metrics described here in quality assurance programmes and optimisation studies with a degree of confidence that they reflect the clinical image quality in chest CR images acquired without an antiscatter grid. A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography.

  6. Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system

    PubMed Central

    Wood, T J; Beavis, A W; Saunderson, J R

    2013-01-01

    Objective: The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. Methods: The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson’s correlation coefficient. Results: Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, p<0.033) and eDE (R=0.77, p<0.008) were observed. Conclusion: Medical physics experts may use the physical image quality metrics described here in quality assurance programmes and optimisation studies with a degree of confidence that they reflect the clinical image quality in chest CR images acquired without an antiscatter grid. Advances in knowledge: A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography. PMID:23568362

  7. Lunate chondromalacia: evaluation of routine MRI sequences.

    PubMed

    Bordalo-Rodrigues, Marcelo; Schweitzer, Mark; Bergin, Diane; Culp, Randall; Barakat, Mohamed S

    2005-05-01

    Chondromalacia is a commonly encountered abnormality at arthroscopy and may be responsible for significant clinical symptoms and disability. In the wrist, the most common location for chondromalacia is the lunate bone. Consequently, we sought to study the accuracy of clinical MRI in the assessment of lunate articular cartilage. MR images of 34 patients who underwent arthroscopy and had an MRI examination within 1 month of surgery were evaluated by two reviewers for the presence and location of lunate cartilage defects and subchondral edema. Lunate cartilage defects were seen on MRI in 10 of the 13 patients with chondromalacia, but these defects were also incorrectly noted in three of 21 of patients without chondromalacia. The visible locations for cartilage defects were the ulnar aspect of the proximal lunate bone (n = 3), radial aspect of the proximal lunate bone (n = 4), ulnar aspect of the distal lunate bone (n = 2), and radial aspect of the distal lunate bone (n = 1). Subchondral marrow edema was observed in six of the 10 patients with chondromalacia seen on MRI; in all six patients, the edema was seen in the same quadrant as the cartilage defect. Marrow edema was detected in one patient without chondromalacia. We conclude that lunate chondromalacia can be accurately assessed using routine MRI sequences, although there are occasional false-positive interpretations.

  8. TH-A-18A-01: Innovation in Clinical Breast Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, B; Yang, K; Yaffe, M

    Several novel modalities have been or are on the verge of being introduced into the breast imaging clinic. These include tomosynthesis imaging, dedicated breast CT, contrast-enhanced digital mammography, and automated breast ultrasound, all of which are covered in this course. Tomosynthesis and dedicated breast CT address the problem of tissue superimposition that limits mammography screening performance, by improved or full resolution of the 3D breast morphology. Contrast-enhanced digital mammography provides functional information that allows for visualization of tumor angiogenesis. 3D breast ultrasound has high sensitivity for tumor detection in dense breasts, but the imaging exam was traditionally performed by radiologists.more » In automated breast ultrasound, the scan is performed in an automated fashion, making for a more practical imaging tool, that is now used as an adjunct to digital mammography in breast cancer screening. This course will provide medical physicists with an in-depth understanding of the imaging physics of each of these four novel imaging techniques, as well as the rationale and implementation of QC procedures. Further, basic clinical applications and work flow issues will be discussed. Learning Objectives: To be able to describe the underlying physical and physiological principles of each imaging technique, and to understand the corresponding imaging acquisition process. To be able to describe the critical system components and their performance requirements. To understand the rationale and implementation of quality control procedures, as well as regulatory requirements for systems with FDA approval. To learn about clinical applications and understand risks and benefits/strength and weakness of each modality in terms of clinical breast imaging.« less

  9. Image-analysis library

    NASA Technical Reports Server (NTRS)

    1980-01-01

    MATHPAC image-analysis library is collection of general-purpose mathematical and statistical routines and special-purpose data-analysis and pattern-recognition routines for image analysis. MATHPAC library consists of Linear Algebra, Optimization, Statistical-Summary, Densities and Distribution, Regression, and Statistical-Test packages.

  10. [Possibilities of sonographic image fusion: Current developments].

    PubMed

    Jung, E M; Clevert, D-A

    2015-11-01

    For diagnostic and interventional procedures ultrasound (US) image fusion can be used as a complementary imaging technique. Image fusion has the advantage of real time imaging and can be combined with other cross-sectional imaging techniques. With the introduction of US contrast agents sonography and image fusion have gained more importance in the detection and characterization of liver lesions. Fusion of US images with computed tomography (CT) or magnetic resonance imaging (MRI) facilitates the diagnostics and postinterventional therapy control. In addition to the primary application of image fusion in the diagnosis and treatment of liver lesions, there are more useful indications for contrast-enhanced US (CEUS) in routine clinical diagnostic procedures, such as intraoperative US (IOUS), vascular imaging and diagnostics of other organs, such as the kidneys and prostate gland.

  11. Clinical Neuropathology practice news 1-2014: Pyrosequencing meets clinical and analytical performance criteria for routine testing of MGMT promoter methylation status in glioblastoma

    PubMed Central

    Preusser, Matthias; Berghoff, Anna S.; Manzl, Claudia; Filipits, Martin; Weinhäusel, Andreas; Pulverer, Walter; Dieckmann, Karin; Widhalm, Georg; Wöhrer, Adelheid; Knosp, Engelbert; Marosi, Christine; Hainfellner, Johannes A.

    2014-01-01

    Testing of the MGMT promoter methylation status in glioblastoma is relevant for clinical decision making and research applications. Two recent and independent phase III therapy trials confirmed a prognostic and predictive value of the MGMT promoter methylation status in elderly glioblastoma patients. Several methods for MGMT promoter methylation testing have been proposed, but seem to be of limited test reliability. Therefore, and also due to feasibility reasons, translation of MGMT methylation testing into routine use has been protracted so far. Pyrosequencing after prior DNA bisulfite modification has emerged as a reliable, accurate, fast and easy-to-use method for MGMT promoter methylation testing in tumor tissues (including formalin-fixed and paraffin-embedded samples). We performed an intra- and inter-laboratory ring trial which demonstrates a high analytical performance of this technique. Thus, pyrosequencing-based assessment of MGMT promoter methylation status in glioblastoma meets the criteria of high analytical test performance and can be recommended for clinical application, provided that strict quality control is performed. Our article summarizes clinical indications, practical instructions and open issues for MGMT promoter methylation testing in glioblastoma using pyrosequencing. PMID:24359605

  12. Patients' perceptions of sharing in decisions: a systematic review of interventions to enhance shared decision making in routine clinical practice.

    PubMed

    Légaré, France; Turcotte, Stéphane; Stacey, Dawn; Ratté, Stéphane; Kryworuchko, Jennifer; Graham, Ian D

    2012-01-01

    Shared decision making is the process in which a healthcare choice is made jointly by the health professional and the patient. Little is known about what patients view as effective or ineffective strategies to implement shared decision making in routine clinical practice. This systematic review evaluates the effectiveness of interventions to improve health professionals' adoption of shared decision making in routine clinical practice, as seen by patients. We searched electronic databases (PubMed, the Cochrane Library, EMBASE, CINAHL, and PsycINFO) from their inception to mid-March 2009. We found additional material by reviewing the reference lists of the studies found in the databases; systematic reviews of studies on shared decision making; the proceedings of various editions of the International Shared Decision Making Conference; and the transcripts of the Society for Medical Decision Making's meetings. In our study selection, we included randomized controlled trials, controlled clinical trials, controlled before-and-after studies, and interrupted time series analyses in which patients evaluated interventions to improve health professionals' adoption of shared decision making. The interventions in question consisted of the distribution of printed educational material; educational meetings; audit and feedback; reminders; and patient-mediated initiatives (e.g. patient decision aids). Two reviewers independently screened the studies and extracted data. Statistical analyses considered categorical and continuous process measures. We computed the standardized effect size for each outcome at the 95% confidence interval. The primary outcome of interest was health professionals' adoption of shared decision making as reported by patients in a self-administered questionnaire. Of the 6764 search results, 21 studies reported 35 relevant comparisons. Overall, the quality of the studies ranged from 0% to 83%. Only three of the 21 studies reported a clinically significant effect

  13. Recommendations for imaging tumor response in neurofibromatosis clinical trials

    PubMed Central

    Ardern-Holmes, Simone L.; Babovic-Vuksanovic, Dusica; Barker, Fred G.; Connor, Steve; Evans, D. Gareth; Fisher, Michael J.; Goutagny, Stephane; Harris, Gordon J.; Jaramillo, Diego; Karajannis, Matthias A.; Korf, Bruce R.; Mautner, Victor; Plotkin, Scott R.; Poussaint, Tina Y.; Robertson, Kent; Shih, Chie-Schin; Widemann, Brigitte C.

    2013-01-01

    Objective: Neurofibromatosis (NF)-related benign tumors such as plexiform neurofibromas (PN) and vestibular schwannomas (VS) can cause substantial morbidity. Clinical trials directed at these tumors have become available. Due to differences in disease manifestations and the natural history of NF-related tumors, response criteria used for solid cancers (1-dimensional/RECIST [Response Evaluation Criteria in Solid Tumors] and bidimensional/World Health Organization) have limited applicability. No standardized response criteria for benign NF tumors exist. The goal of the Tumor Measurement Working Group of the REiNS (Response Evaluation in Neurofibromatosis and Schwannomatosis) committee is to propose consensus guidelines for the evaluation of imaging response in clinical trials for NF tumors. Methods: Currently used imaging endpoints, designs of NF clinical trials, and knowledge of the natural history of NF-related tumors, in particular PN and VS, were reviewed. Consensus recommendations for response evaluation for future studies were developed based on this review and the expertise of group members. Results: MRI with volumetric analysis is recommended to sensitively and reproducibly evaluate changes in tumor size in clinical trials. Volumetric analysis requires adherence to specific imaging recommendations. A 20% volume change was chosen to indicate a decrease or increase in tumor size. Use of these criteria in future trials will enable meaningful comparison of results across studies. Conclusions: The proposed imaging response evaluation guidelines, along with validated clinical outcome measures, will maximize the ability to identify potentially active agents for patients with NF and benign tumors. PMID:24249804

  14. Recommendations for imaging tumor response in neurofibromatosis clinical trials.

    PubMed

    Dombi, Eva; Ardern-Holmes, Simone L; Babovic-Vuksanovic, Dusica; Barker, Fred G; Connor, Steve; Evans, D Gareth; Fisher, Michael J; Goutagny, Stephane; Harris, Gordon J; Jaramillo, Diego; Karajannis, Matthias A; Korf, Bruce R; Mautner, Victor; Plotkin, Scott R; Poussaint, Tina Y; Robertson, Kent; Shih, Chie-Schin; Widemann, Brigitte C

    2013-11-19

    Neurofibromatosis (NF)-related benign tumors such as plexiform neurofibromas (PN) and vestibular schwannomas (VS) can cause substantial morbidity. Clinical trials directed at these tumors have become available. Due to differences in disease manifestations and the natural history of NF-related tumors, response criteria used for solid cancers (1-dimensional/RECIST [Response Evaluation Criteria in Solid Tumors] and bidimensional/World Health Organization) have limited applicability. No standardized response criteria for benign NF tumors exist. The goal of the Tumor Measurement Working Group of the REiNS (Response Evaluation in Neurofibromatosis and Schwannomatosis) committee is to propose consensus guidelines for the evaluation of imaging response in clinical trials for NF tumors. Currently used imaging endpoints, designs of NF clinical trials, and knowledge of the natural history of NF-related tumors, in particular PN and VS, were reviewed. Consensus recommendations for response evaluation for future studies were developed based on this review and the expertise of group members. MRI with volumetric analysis is recommended to sensitively and reproducibly evaluate changes in tumor size in clinical trials. Volumetric analysis requires adherence to specific imaging recommendations. A 20% volume change was chosen to indicate a decrease or increase in tumor size. Use of these criteria in future trials will enable meaningful comparison of results across studies. The proposed imaging response evaluation guidelines, along with validated clinical outcome measures, will maximize the ability to identify potentially active agents for patients with NF and benign tumors.

  15. Multimodal image analysis of clinical influences on preterm brain development

    PubMed Central

    Ball, Gareth; Aljabar, Paul; Nongena, Phumza; Kennea, Nigel; Gonzalez‐Cinca, Nuria; Falconer, Shona; Chew, Andrew T.M.; Harper, Nicholas; Wurie, Julia; Rutherford, Mary A.; Edwards, A. David

    2017-01-01

    Objective Premature birth is associated with numerous complex abnormalities of white and gray matter and a high incidence of long‐term neurocognitive impairment. An integrated understanding of these abnormalities and their association with clinical events is lacking. The aim of this study was to identify specific patterns of abnormal cerebral development and their antenatal and postnatal antecedents. Methods In a prospective cohort of 449 infants (226 male), we performed a multivariate and data‐driven analysis combining multiple imaging modalities. Using canonical correlation analysis, we sought separable multimodal imaging markers associated with specific clinical and environmental factors and correlated to neurodevelopmental outcome at 2 years. Results We found five independent patterns of neuroanatomical variation that related to clinical factors including age, prematurity, sex, intrauterine complications, and postnatal adversity. We also confirmed the association between imaging markers of neuroanatomical abnormality and poor cognitive and motor outcomes at 2 years. Interpretation This data‐driven approach defined novel and clinically relevant imaging markers of cerebral maldevelopment, which offer new insights into the nature of preterm brain injury. Ann Neurol 2017;82:233–246 PMID:28719076

  16. Feasibility and Acceptability of Implementing Indirect Calorimetry Into Routine Clinical Care of Patients With Spinal Cord Injury

    PubMed Central

    Mayr, Hannah; Atresh, Sridhar; Kemp, Irene; Simmons, Joshua; Vivanti, Angela; Hickman, Ingrid J.

    2016-01-01

    Background: In the absence of reliable predictive equations, indirect calorimetry (IC) remains the gold standard for assessing energy requirements after spinal cord injury (SCI), but it is typically confined to a research setting. The purpose of this study is to assess the feasibility and acceptability of implementing IC into routine clinical care in an Australian SCI rehabilitation facility. Methods: Bedside IC (canopy hood) was performed, and patients completed an IC acceptability questionnaire (open-ended; yes/no; 5-point Likert scale). Fasted resting energy expenditure (REE) steady-state criteria were applied to assess data quality, and adherence to a test ≥20 minutes was recorded. Staff were surveyed to assess impact of IC on usual care. Results: Of 35 eligible patients, 9 declined (7 reported claustrophobia). One patient could not be tested before discharge and 25 underwent IC (84% male, injury level C2-L2, AIS A-D). Anxiety prevented one patient from completing IC, while another failed to fast. The remaining 23 patients achieved a steady-state REE (≥5 consecutive minutes with ≤10% coefficient of variation for VO2 and VCO2). Test-retest (n = 5) showed <10% variation in REE. Patients deemed the procedure acceptable, with 88% reporting a willingness to repeat IC. Eighty percent of patients and 90% of staff agreed it was acceptable for IC to be integrated into usual care. Conclusion: This study found that IC is a feasible and acceptable addition to the routine clinical care of patients recovering from SCI and may serve to improve accuracy of nutrition interventions for this patient population. PMID:29339868

  17. Clinical imaging in regenerative medicine

    PubMed Central

    Naumova, Anna V; Modo, Michel; Moore, Anna; Murry, Charles E; Frank, Joseph A

    2014-01-01

    In regenerative medicine, clinical imaging is indispensable for characterizing damaged tissue and for measuring the safety and efficacy of therapy. However, the ability to track the fate and function of transplanted cells with current technologies is limited. Exogenous contrast labels such as nanoparticles give a strong signal in the short term but are unreliable long term. Genetically encoded labels are good both short- and long-term in animals, but in the human setting they raise regulatory issues related to the safety of genomic integration and potential immunogenicity of reporter proteins. Imaging studies in brain, heart and islets share a common set of challenges, including developing novel labeling approaches to improve detection thresholds and early delineation of toxicity and function. Key areas for future research include addressing safety concerns associated with genetic labels and developing methods to follow cell survival, differentiation and integration with host tissue. Imaging may bridge the gap between cell therapies and health outcomes by elucidating mechanisms of action through longitudinal monitoring. PMID:25093889

  18. Image-guided cancer surgery using near-infrared fluorescence

    PubMed Central

    Vahrmeijer, Alexander L.; Hutteman, Merlijn; van der Vorst, Joost R.; van de Velde, C.J.H.; Frangioni, John V.

    2013-01-01

    Paradigm shifts in surgery arise when surgeons are empowered to perform surgery faster, better, and/or less expensively. Optical imaging that exploits invisible near-infrared fluorescent light has the potential to improve cancer surgery outcomes while minimizing anesthesia time and lowering healthcare costs. Because of this, the last few years have witnessed an explosion of proof-of-concept clinical trials in the field. In this review, we introduce the concept of near-infrared fluorescence imaging for cancer surgery, review the clinical trial literature to date, outline the key issues pertaining to imaging system and contrast agent optimization, discuss limitations and leverage, and provide a framework for making the technology available for the routine care of cancer patients in the near future. PMID:23881033

  19. Factors Associated with Routine Dental Attendance among Aboriginal Australians.

    PubMed

    Amarasena, Najith; Kapellas, Kostas; Skilton, Michael R; Maple-Brown, Louise J; Brown, Alex; Bartold, Mark; O'Dea, Kerin; Celermajer, David; Jamieson, Lisa M

    2016-01-01

    To determine factors associated with routine dental attendance in Aboriginal Australians. Data of 271 Aboriginal adults residing in Australia's Northern Territory were used. Routine dental attendance was defined as last visiting a dentist less than one year ago or visiting a dentist for a check-up. Both bivariate and multivariable analytical techniques were used. While 27% visited a dentist in the past year, 29% of these visited for a check-up. In bivariate analysis, being female, low psychological distress, and low clinical attachment loss (CAL) were associated with visiting a dentist within last year. Being aged younger than 39 years, male, no oral health impairment, being caries-free, low CAL, and low apolipoprotein B were associated with visiting for a check-up. Clinical attachment loss remained associated with visiting a dentist less than one year ago while being younger than 39 years and having no oral health impairment remained associated with usually visiting for a check-up in multivariable analysis. Younger age, no oral health impairment, and low CAL were associated with routine dental attendance among Indigenous Australians.

  20. Factors Associated with Routine Dental Attendance among Aboriginal Australians.

    PubMed

    Amarasena, Najith; Kapellas, Kostas; Skilton, Michael R; Maple-Brown, Louise J; Brown, Alex; Bartold, Mark; O'Dea, Kerin; Celermajer, David; Jamieson, Lisa M

    2016-02-01

    To determine factors associated with routine dental attendance in Aboriginal Australians. Data of 271 Aboriginal adults residing in Australia's Northern Territory were used. Routine dental attendance was defined as last visiting a dentist less than one year ago or visiting a dentist for a check-up. Both bivariate and multivariable analytical techniques were used. While 27% visited a dentist in the past year, 29% of these visited for a check-up. In bivariate analysis, being female, low psychological distress, and low clinical attachment loss (CAL) were associated with visiting a dentist within last year. Being aged younger than 39 years, male, no oral health impairment, being caries-free, low CAL, and low apolipoprotein B were associated with visiting for a check-up. Clinical attachment loss remained associated with visiting a dentist less than one year ago while being younger than 39 years and having no oral health impairment remained associated with usually visiting for a check-up in multivariable analysis. Younger age, no oral health impairment, and low CAL were associated with routine dental attendance among Indigenous Australians.

  1. Imaging of cartilage and bone: promises and pitfalls in clinical trials of osteoarthritis

    PubMed Central

    Eckstein, F.; Guermazi, A.; Gold, G.; Duryea, J.; Le Graverand, M.-P. Hellio; Wirth, W.; Miller, C.G.

    2015-01-01

    summary Imaging in clinical trials is used to evaluate subject eligibility, and/or efficacy of intervention, supporting decision making in drug development by ascertaining treatment effects on joint structure. This review focusses on imaging of bone and cartilage in clinical trials of (knee) osteoarthritis. We narratively review the full-text literature on imaging of bone and cartilage, adding primary experience in the implementation of imaging methods in clinical trials. Aims and constraints of applying imaging in clinical trials are outlined. The specific uses of semi-quantitative and quantitative imaging biomarkers of bone and cartilage in osteoarthritis trials are summarized, focusing on radiography and magnetic resonance imaging (MRI). Studies having compared both imaging methodologies directly and those having established a relationship between imaging biomarkers and clinical outcomes are highlighted. To make this review of practical use, recommendations are provided as to which imaging protocols are ideal for capturing specific aspects of bone and cartilage tissue, and pitfalls in their usage are highlighted. Further, the longitudinal sensitivity to change, of different imaging methods is reported for various patient strata. From these power calculations can be accomplished, provided the strength of the treatment effect is known. In conclusion, current imaging methodologies provide powerful tools for scoring and measuring morphological and compositional aspects of most articular tissues, capturing longitudinal change with reasonable to excellent sensitivity. When employed properly, imaging has tremendous potential for ascertaining treatment effects on various joint structures, potentially over shorter time scales than required for demonstrating effects on clinical outcomes. PMID:25278061

  2. [Clinical applications of molecular imaging methods for patients with ischemic stroke].

    PubMed

    Yamauchi, Hiroshi; Fukuyama, Hidenao

    2007-02-01

    Several molecular imaging methods have been developed to visualize pathophysiology of cerebral ischemia in humans in vivo. PET and SPECT with specific ligands have been mainly used as diagnostic tools for the clinical usage of molecular imaging in patients with ischemic stroke. Recently, cellular MR imaging with specific contrast agents has been developed to visualize targeted cells in human stroke patients. This article reviews the current status in the clinical applications of those molecular imaging methods for patients with ischemic stroke.

  3. Imaging evidence and recommendations for traumatic brain injury: advanced neuro- and neurovascular imaging techniques.

    PubMed

    Wintermark, M; Sanelli, P C; Anzai, Y; Tsiouris, A J; Whitlow, C T

    2015-02-01

    Neuroimaging plays a critical role in the evaluation of patients with traumatic brain injury, with NCCT as the first-line of imaging for patients with traumatic brain injury and MR imaging being recommended in specific settings. Advanced neuroimaging techniques, including MR imaging DTI, blood oxygen level-dependent fMRI, MR spectroscopy, perfusion imaging, PET/SPECT, and magnetoencephalography, are of particular interest in identifying further injury in patients with traumatic brain injury when conventional NCCT and MR imaging findings are normal, as well as for prognostication in patients with persistent symptoms. These advanced neuroimaging techniques are currently under investigation in an attempt to optimize them and substantiate their clinical relevance in individual patients. However, the data currently available confine their use to the research arena for group comparisons, and there remains insufficient evidence at the time of this writing to conclude that these advanced techniques can be used for routine clinical use at the individual patient level. TBI imaging is a rapidly evolving field, and a number of the recommendations presented will be updated in the future to reflect the advances in medical knowledge. © 2015 by American Journal of Neuroradiology.

  4. A novel multiwavelength fluorescence image-guided surgery imaging system

    NASA Astrophysics Data System (ADS)

    Volpi, D.; Tullis, I. D. C.; Laios, A.; Pathiraja, P. N. J.; Haldar, K.; Ahmed, A. A.; Vojnovic, B.

    2014-02-01

    We describe the development and performance analysis of two clinical near-infrared fluorescence image-guided surgery (FIGS) devices that aim to overcome some of the limitations of current FIGS systems. The devices operate in a widefield-imaging mode and can work (1) in conjunction with a laparoscope, during minimally invasive surgery, and (2) as a hand-held, open surgery imaging system. In both cases, narrow-band excitation light, delivered at multiple wavelengths, is efficiently combined with white reflectance light. Light is delivered to ~100 cm2 surgical field at 1-2 mW/cm2 for white light and 3-7 mW/cm2 (depending on wavelength) of red - near infrared excitation, at a typical working distance of 350 mm for the hand-held device and 100 mm for the laparoscope. A single, sensitive, miniaturized color camera collects both fluorescence and white reflectance light. The use of a single imager eliminates image alignment and software overlay complexity. A novel filtering and illumination arrangement allows simultaneous detection of white reflectance and fluorescence emission from multiple dyes in real-time. We will present both fluorescence detection sensitivity modeling and practical performance data. We have demonstrated the efficiency and the advantages of the devices both pre-clinically and during live surgery on humans. Both the hand-held and the laparoscopic systems have proved to be reliable and beneficial in an ongoing clinical trial involving sentinel lymph node detection in gynecological cancers. We will show preliminary results using two clinically approved dyes, Methylene blue and indocyanine green. We anticipate that this technology can be integrated and routinely used in a larger variety of surgical procedures.

  5. Prospective evaluation of the VITEK MS for the routine identification of bacteria and yeast in the clinical microbiology laboratory: assessment of accuracy of identification and turnaround time.

    PubMed

    Charnot-Katsikas, Angella; Tesic, Vera; Boonlayangoor, Sue; Bethel, Cindy; Frank, Karen M

    2014-02-01

    This study assessed the accuracy of bacterial and yeast identification using the VITEK MS, and the time to reporting of isolates before and after its implementation in routine clinical practice. Three hundred and sixty-two isolates of bacteria and yeast, consisting of a variety of clinical isolates and American Type Culture Collection strains, were tested. Results were compared with reference identifications from the VITEK 2 system and with 16S rRNA sequence analysis. The VITEK MS provided an acceptable identification to species level for 283 (78 %) isolates. Considering organisms for which genus-level identification is acceptable for routine clinical care, 315 isolates (87 %) had an acceptable identification. Six isolates (2 %) were identified incorrectly, five of which were Shigella species. Finally, the time for reporting the identifications was decreased significantly after implementation of the VITEK MS for a total mean reduction in time of 10.52 h (P<0.0001). Overall, accuracy of the VITEK MS was comparable or superior to that from the VITEK 2. The findings were also comparable to other studies examining the accuracy of the VITEK MS, although differences exist, depending on the diversity of species represented as well as on the versions of the databases used. The VITEK MS can be incorporated effectively into routine use in a clinical microbiology laboratory and future expansion of the database should provide improved accuracy for the identification of micro-organisms.

  6. X-Ray and near-infrared imaging: similarities, differences and combinations

    NASA Astrophysics Data System (ADS)

    Pogue, Brian W.

    2010-02-01

    The integration of x-ray imaging with optical imaging is becoming routine at the pre-clinical level, as both projection and tomography systems are now commercially integrated as packaged systems. Yet, the differences between their capabilities are wide, and there is still perhaps a lack of appreciation about how difference pre-clinical x-ray systems are from clinical x-ray systems. In this survey, the key advantages of each approach, x-ray and optical, are described, and the potential synergies and deficiencies are discussed. In simple terms, the major benefit of optical imaging is in the spectroscopic capabilities, which allow the potential for imaging fluorescent agents in vivo, and the future potential for imaging multiple species at a time with spectral discrimination or spectral fitting of the data. In comparison, multienergy x-ray systems are being realized in clinical use, or automated discrimination of soft versus hard tissues, and the combination of optical imaging with this type of dual-energy x-ray imaging will significantly enhance the capabilities of the hybrid systems. Unfortunately, the power of dual energy imaging is not as possible at the pre-clinical stage, because of the limitations of contrast-resolution and x-ray dose. This is discussed and future human systems outlined.

  7. Clinical use of an epinephrine-reduced (1/400,000) articaine solution in short-time dental routine treatments--a multicenter study.

    PubMed

    Daubländer, Monika; Kämmerer, Peer W; Willershausen, Brita; Leckel, Michael; Lauer, Hans-Christoph; Buff, Siegmar; Rösl, Benita

    2012-08-01

    The addition of epinephrine in dental local anaesthesia results in a longer and deeper anaesthesia under almost ischemic conditions. For short-time dental treatments, epinephrine-reduced anaesthetics may offer shorter and more individual anaesthesia with reduced potential side effects. The aim of this study was a clinical evaluation of anaesthetic potency and adverse effects of an epinephrine-reduced articaine formulation in dental patients undergoing short-time routine treatment. In a prospective clinical, not interventional, study between January 2008 and February 2009, 908 patients undergoing short-time dental treatment in five medical centers were anaesthetized with 4% articaine 1:400,000 epinephrine (Ubistesin, 3M/ESPE, Seefeld, Germany). Efficacy and safety in clinical use were evaluated. A follow-up after 1 day was conducted by telephone survey. A mean amount of 1.3-ml anaesthetic solution was needed to achieve a complete or sufficient anaesthesia in 97% (n = 876) of cases. A second injection had to be done in 3.7% (n = 34) before and in 11.9% (n = 108) during treatment. Here, the second injection had to be applied after a mean of 48.6 min. The mean duration of soft tissue anaesthesia after infiltration was 146.6 min, after nerve block 187.7 min. The painful treatment took a mean of 50.2 min and the total treatment time summed up to 68.8 min. In 1.7% cases (n = 15), unwanted side effects were observed. The results indicate that a lower concentration of epinephrine in combination with the 4% articaine solution leads to a high success rate of efficacy. The clinical use of a 4% articaine 1:400,000 epinephrine solution can be stated as safe and effective in short dental routine treatments. Reconsiderations concerning limitations of indication or additional contraindications are not necessary.

  8. SU-F-T-567: Sensitivity and Reproducibility of the Portal Imaging Panel for Routine FFF QC and Patient Plan Dose Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willett, A; Gilmore, M; Rowbottom, C

    2016-06-15

    Purpose: The purpose of this work was to see if the EPID is a viable alternative to other QA devices for routine FFF QA and plan dose measurements. Methods: Sensitivity measurements were made to assess response to small changes in field size and beam steering. QA plans were created where field size was varied from baseline values (5–5.5cm, 20–20.5cm). Beam steering was adjusted by altering values in service mode (Symmetry 0–3%). Plans were measured using the Varian portal imager (aS1200 DMI panel), QA3 (Sun Nuclear), and Starcheck Maxi (PTW). FFF beam parameters as stated in Fogliata et al were calculated.more » Constancy measurements were taken using all 3 QC devices to measure a MLC defined 20×20cm field. Two clinical SABR patient plans were measured on a Varian Edge linac, using the Portal Dosimetry module in ARIA, and results compared with analysis made using Delta4 (ScandiDos). Results: The EPID and the Starcheck performed better at detecting clinically relevant changes in field size with the QA3 performing better when detecting similar changes in beam symmetry. Consistency measurements with the EPID and Starcheck were equivalent, with comparable standard deviations. Clinical plan measurements on the EPID compared well with Delta4 results at 3%/1mm. Conclusion: Our results show that for FFF QA measurements such as field size and symmetry, using the EPID is a viable alternative to other QA devices. The EPID could potentially be used for QC measurements with a focus on geometric accuracy, such as MLC positional QA, due to its high resolution compared to other QA devices (EPID 0.34mm, Starcheck 3mm, QA3 5mm). Good agreement between Delta4 and portal dosimetry also indicated the EPID may be a suitable alternative for measurement of clinical plans.« less

  9. Magnetic particle imaging: from proof of principle to preclinical applications

    NASA Astrophysics Data System (ADS)

    Knopp, T.; Gdaniec, N.; Möddel, M.

    2017-07-01

    Tomographic imaging has become a mandatory tool for the diagnosis of a majority of diseases in clinical routine. Since each method has its pros and cons, a variety of them is regularly used in clinics to satisfy all application needs. Magnetic particle imaging (MPI) is a relatively new tomographic imaging technique that images magnetic nanoparticles with a high spatiotemporal resolution in a quantitative way, and in turn is highly suited for vascular and targeted imaging. MPI was introduced in 2005 and now enters the preclinical research phase, where medical researchers get access to this new technology and exploit its potential under physiological conditions. Within this paper, we review the development of MPI since its introduction in 2005. Besides an in-depth description of the basic principles, we provide detailed discussions on imaging sequences, reconstruction algorithms, scanner instrumentation and potential medical applications.

  10. SPECT and PET radiopharmaceuticals for molecular imaging of apoptosis: from bench to clinic

    PubMed Central

    Wang, Xiaobo; Feng, Han; Zhao, Shichao; Xu, Junling; Wu, Xinyu; Cui, Jing; Zhang, Ying; Qin, Yuhua; Liu, Zhiguo; Gao, Tang; Gao, Yongju; Zeng, Wenbin

    2017-01-01

    Owing to the central role of apoptosis in many human diseases and the wide-spread application of apoptosis-based therapeutics, molecular imaging of apoptosis in clinical practice is of great interest for clinicians, and holds great promises. Based on the well-defined biochemical changes for apoptosis, a rich assortment of probes and approaches have been developed for molecular imaging of apoptosis with various imaging modalities. Among these imaging techniques, nuclear imaging (including single photon emission computed tomography and positron emission tomography) remains the premier clinical method owing to their high specificity and sensitivity. Therefore, the corresponding radiopharmaceuticals have been a major focus, and some of them like 99mTc-Annexin V, 18F-ML-10, 18F-CP18, and 18F-ICMT-11 are currently under clinical investigations in Phase I/II or Phase II/III clinical trials on a wide scope of diseases. In this review, we summarize these radiopharmaceuticals that have been widely used in clinical trials and elaborate them in terms of radiosynthesis, pharmacokinetics and dosimetry, and their applications in different clinical stages. We also explore the unique features required to qualify a desirable radiopharmaceutical for imaging apoptosis in clinical practice. Particularly, a perspective of the impact of these clinical efforts, namely, apoptosis imaging as predictive and prognostic markers, early-response indicators and surrogate endpoints, is also the highlight of this review. PMID:28108738

  11. Comparison of clinical and physics scoring of PET images when image reconstruction parameters are varied.

    PubMed

    Walsh, C; Johnston, C; Sheehy, N; O' Reilly, G

    2013-02-01

    In this study the quantitative and qualitative image quality (IQ) measurements with clinical judgement of IQ in positron emission tomography (PET) were compared. The limitations of IQ metrics and the proposed criteria of acceptability for PET scanners are discussed. Phantom and patient images were reconstructed using seven different iterative reconstruction protocols. For each reconstructed set of images, IQ was scored based both on the visual analysis and on the quantitative metrics. The quantitative physics metrics did not rank the reconstruction protocols in the same order as the clinicians' scoring of perceived IQ (R(s)=-0.54). Better agreement was achieved when comparing the clinical perception of IQ to the physicist's visual assessment of IQ in the phantom images (R(s)=+0.59). The closest agreement was seen between the quantitative physics metrics and the measurement of the standard uptake values (SUVs) in small tumours (R(s)=+0.92). Given the disparity between the clinical perception of IQ and the physics metrics a cautious approach to use of IQ measurements for determining suspension levels is warranted.

  12. SU-E-T-23: A Developing Australian Network for Datamining and Modelling Routine Radiotherapy Clinical Data and Radiomics Information for Rapid Learning and Clinical Decision Support

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thwaites, D; Holloway, L; Bailey, M

    2015-06-15

    Purpose: Large amounts of routine radiotherapy (RT) data are available, which can potentially add clinical evidence to support better decisions. A developing collaborative Australian network, with a leading European partner, aims to validate, implement and extend European predictive models (PMs) for Australian practice and assess their impact on future patient decisions. Wider objectives include: developing multi-institutional rapid learning, using distributed learning approaches; and assessing and incorporating radiomics information into PMs. Methods: Two initial standalone pilots were conducted; one on NSCLC, the other on larynx, patient datasets in two different centres. Open-source rapid learning systems were installed, for data extraction andmore » mining to collect relevant clinical parameters from the centres’ databases. The European DSSs were learned (“training cohort”) and validated against local data sets (“clinical cohort”). Further NSCLC studies are underway in three more centres to pilot a wider distributed learning network. Initial radiomics work is underway. Results: For the NSCLC pilot, 159/419 patient datasets were identified meeting the PM criteria, and hence eligible for inclusion in the curative clinical cohort (for the larynx pilot, 109/125). Some missing data were imputed using Bayesian methods. For both, the European PMs successfully predicted prognosis groups, but with some differences in practice reflected. For example, the PM-predicted good prognosis NSCLC group was differentiated from a combined medium/poor prognosis group (2YOS 69% vs. 27%, p<0.001). Stage was less discriminatory in identifying prognostic groups. In the good prognosis group two-year overall survival was 65% in curatively and 18% in palliatively treated patients. Conclusion: The technical infrastructure and basic European PMs support prognosis prediction for these Australian patient groups, showing promise for supporting future personalized treatment decisions

  13. Clinical perspectives of hybrid proton-fluorine magnetic resonance imaging and spectroscopy.

    PubMed

    Wolters, Martijn; Mohades, Seyede G; Hackeng, Tilman M; Post, Mark J; Kooi, Marianne E; Backes, Walter H

    2013-05-01

    The number of applications of fluorine 19 (19F) magnetic resonance (MR) imaging and spectroscopy in biomedical and clinical research is steadily growing. The 100% natural abundance of fluorine and its relatively high sensitivity for MR (83% to that of protons) make it an interesting nucleus for a wide range of MR applications. Fluorinated contrast media have a number of advantages over the conventionally used gadolinium-based or iron-based contrast agents. The absence of an endogenous fluorine background intensity in the human body facilitates reliable quantification of fluorinated contrast medium or drugs. Anatomy can be visualized separately with proton MR imaging, creating the application of hybrid hydrogen 1 (1H)/19F MR imaging. The availability of 2 channels (ie, the 1H and 19F channels) enables dual-targeted molecular imaging. Recently, novel developments have emerged on fluorine-based contrast media in preclinical studies and imaging techniques. The developments in fluorine MR seem promising for clinical applications, with contributions in therapy monitoring, assessment of lung function, angiography, and molecular imaging. This review outlines the translation from recent advances in preclinical MR imaging and spectroscopy to future perspectives of clinical hybrid 1H/19/F MR imaging applications.

  14. Human brain diffusion tensor imaging at submillimeter isotropic resolution on a 3 Tesla clinical MRI scanner

    PubMed Central

    Chang, Hing-Chiu; Sundman, Mark; Petit, Laurent; Guhaniyogi, Shayan; Chu, Mei-Lan; Petty, Christopher; Song, Allen W.; Chen, Nan-kuei

    2015-01-01

    The advantages of high-resolution diffusion tensor imaging (DTI) have been demonstrated in a recent post-mortem human brain study (Miller et al., NeuroImage 2011;57(1):167–181), showing that white matter fiber tracts can be much more accurately detected in data at submillimeter isotropic resolution. To our knowledge, in vivo human brain DTI at submillimeter isotropic resolution has not been routinely achieved yet because of the difficulty in simultaneously achieving high resolution and high signal-to-noise ratio (SNR) in DTI scans. Here we report a 3D multi-slab interleaved EPI acquisition integrated with multiplexed sensitivity encoded (MUSE) reconstruction, to achieve high-quality, high-SNR and submillimeter isotropic resolution (0.85 × 0.85 × 0.85 mm3) in vivo human brain DTI on a 3 Tesla clinical MRI scanner. In agreement with the previously reported post-mortem human brain DTI study, our in vivo data show that the structural connectivity networks of human brains can be mapped more accurately and completely with high-resolution DTI as compared with conventional DTI (e.g., 2 × 2 × 2 mm3). PMID:26072250

  15. Intensive cognitive therapy for post-traumatic stress disorder in routine clinical practice: A matched comparison audit.

    PubMed

    Murray, Hannah; El-Leithy, Sharif; Billings, Jo

    2017-11-01

    Intensive cognitive therapy for post-traumatic stress disorder (PTSD) has been shown to be as effective as weekly treatment in controlled trials. In this study, outcome data comparing standard and intensive treatments delivered in routine clinical practice were analysed. A consecutive case series of intensive treatment cases were compared to matched control cases who had completed weekly treatment. Both groups showed significant improvements on PTSD and depression measures. The intensive group showed larger PTSD symptomatic improvement. There were differences between the groups in age and time since trauma, suggesting selection biases in who is offered, and/or who chooses intensive treatment. For some individuals, an intensive format may be more effective than weekly treatment. © 2017 The British Psychological Society.

  16. Randomized clinical trial of Appendicitis Inflammatory Response score-based management of patients with suspected appendicitis.

    PubMed

    Andersson, M; Kolodziej, B; Andersson, R E

    2017-10-01

    The role of imaging in the diagnosis of appendicitis is controversial. This prospective interventional study and nested randomized trial analysed the impact of implementing a risk stratification algorithm based on the Appendicitis Inflammatory Response (AIR) score, and compared routine imaging with selective imaging after clinical reassessment. Patients presenting with suspicion of appendicitis between September 2009 and January 2012 from age 10 years were included at 21 emergency surgical centres and from age 5 years at three university paediatric centres. Registration of clinical characteristics, treatments and outcomes started during the baseline period. The AIR score-based algorithm was implemented during the intervention period. Intermediate-risk patients were randomized to routine imaging or selective imaging after clinical reassessment. The baseline period included 1152 patients, and the intervention period 2639, of whom 1068 intermediate-risk patients were randomized. In low-risk patients, use of the AIR score-based algorithm resulted in less imaging (19·2 versus 34·5 per cent; P < 0·001), fewer admissions (29·5 versus 42·8 per cent; P < 0·001), and fewer negative explorations (1·6 versus 3·2 per cent; P = 0·030) and operations for non-perforated appendicitis (6·8 versus 9·7 per cent; P = 0·034). Intermediate-risk patients randomized to the imaging and observation groups had the same proportion of negative appendicectomies (6·4 versus 6·7 per cent respectively; P = 0·884), number of admissions, number of perforations and length of hospital stay, but routine imaging was associated with an increased proportion of patients treated for appendicitis (53·4 versus 46·3 per cent; P = 0·020). AIR score-based risk classification can safely reduce the use of diagnostic imaging and hospital admissions in patients with suspicion of appendicitis. Registration number: NCT00971438 ( http://www.clinicaltrials.gov). © 2017 BJS

  17. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies

    PubMed Central

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-01-01

    Objective To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Methods and results Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2  =  0.92 versus r2  =  0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (κ  =  0.87 v κ  =  0.75, p < 0.05). Conclusion MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine. PMID:15939722

  18. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies.

    PubMed

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-03-01

    To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2 = 0.92 versus r2 = 0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (kappa = 0.87 v kappa = 0.75, p < 0.05). MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine.

  19. NOVEL OBSERVATIONS AND POTENTIAL APPLICATIONS USING DIGITAL INFRARED IRIS IMAGING

    PubMed Central

    Roberts, Daniel K.; Lukic, Ana; Yang, Yongyi; Moroi, Sayoko E.; Wilensky, Jacob T.; Wernick, Miles N.

    2017-01-01

    Digital infrared (IR) iris photography using a modified digital camera system was carried out on about 300 subjects seen during routine clinical care and research at one facility. Since this image database offered opportunity to gain new insight into the potential utility of IR iris imaging, it was surveyed for unique image patterns. Then, a selection of photos was compiled that would illustrate the spectrum of this imaging experience. Potentially informative image patterns were observed in subjects with cataracts, diabetic retinopathy, Posner-Schlossman syndrome, iridociliary cysts, long anterior lens zonules, nevi, oculocutaneous albinism, pigment dispersion syndrome, pseudophakia, suspected vascular anomaly, and trauma. Image patterns were often unanticipated regardless of pre-existing information and suggest that IR iris imaging may have numerous potential clinical and research applications, some of which may still not be recognized. These observations suggest further development and study of this technology. PMID:19320317

  20. Clinical and Magnetic Resonance Imaging Findings of Neurotoxocariasis.

    PubMed

    Sánchez, Sofia S; García, Hector H; Nicoletti, Alessandra

    2018-01-01

    Human toxocariasis is one of the most prevalent helminthiases worldwide. Toxocara canis larvae can cross the blood-brain barrier leading to the neurotoxocariasis. The clinical presentation consists of a wide spectrum of neurological manifestations, but asymptomatic infection is probably common. Neurotoxocariasis is not a frequent diagnosis probably due to the non-specific nature of its symptoms as well as the lack of confirmatory diagnostic tests. Diagnosis of neurotoxocariasis is based on the presence of a high titer of anti- Toxocara antibody in the cerebrospinal fluid or in the serum, presence of eosinophilia in the serum or cerebrospinal fluid, and clinical and radiological improvement after anthelmintic therapy; however, universally accepted diagnostic criteria are lacking. Magnetic resonance imaging (MRI) findings include single or multiple, subcortical, cortical or white matter hyperintense lesions, best visualized on FLAIR and T2-weighted imaging, and usually isointense or hypointense on T1. These imaging findings are suggestive but not specific to neurotoxocariasis. Definitive diagnosis is made by histological confirmation, but it is rarely followed. This review provides an overview of the clinical manifestations, management options, and MRI findings of neurotoxocariasis.

  1. Clinical and Magnetic Resonance Imaging Findings of Neurotoxocariasis

    PubMed Central

    Sánchez, Sofia S.; García, Hector H.; Nicoletti, Alessandra

    2018-01-01

    Human toxocariasis is one of the most prevalent helminthiases worldwide. Toxocara canis larvae can cross the blood–brain barrier leading to the neurotoxocariasis. The clinical presentation consists of a wide spectrum of neurological manifestations, but asymptomatic infection is probably common. Neurotoxocariasis is not a frequent diagnosis probably due to the non-specific nature of its symptoms as well as the lack of confirmatory diagnostic tests. Diagnosis of neurotoxocariasis is based on the presence of a high titer of anti-Toxocara antibody in the cerebrospinal fluid or in the serum, presence of eosinophilia in the serum or cerebrospinal fluid, and clinical and radiological improvement after anthelmintic therapy; however, universally accepted diagnostic criteria are lacking. Magnetic resonance imaging (MRI) findings include single or multiple, subcortical, cortical or white matter hyperintense lesions, best visualized on FLAIR and T2-weighted imaging, and usually isointense or hypointense on T1. These imaging findings are suggestive but not specific to neurotoxocariasis. Definitive diagnosis is made by histological confirmation, but it is rarely followed. This review provides an overview of the clinical manifestations, management options, and MRI findings of neurotoxocariasis. PMID:29472889

  2. Using routinely recorded data in the UK to assess outcomes in a randomised controlled trial: The Trials of Access.

    PubMed

    Powell, G A; Bonnett, L J; Tudur-Smith, C; Hughes, D A; Williamson, P R; Marson, A G

    2017-08-23

    In the UK, routinely recorded data may benefit prospective studies including randomised controlled trials (RCTs). In an on-going study, we aim to assess the feasibility of access and agreement of routinely recorded clinical and non-clinical data compared to data collected during a RCT using standard prospective methods. This paper will summarise available UK routinely recorded data sources and discuss our experience with the feasibility of accessing routinely recorded data for participants of a RCT before finally proposing recommendations for improving the access and implementation of routinely recorded data in RCTs. Setting: the case study RCT is the Standard and New Antiepileptic Drugs II (SANAD II) trial, a pragmatic, UK, multicentre, phase IV RCT assessing the clinical and cost-effectiveness of antiepileptic drug treatments for newly diagnosed epilepsy. 98 participants have provided written consent to permit the request of routinely recorded data. Study procedures: routinely recorded clinical and non-clinical data were identified and data requested through formal applications from available data holders for the duration that participants have been recruited into SANAD II. The feasibility of accessing routinely recorded data during a RCT is assessed and recommendations for improving access proposed. Secondary-care clinical and socioeconomic data is recorded on a national basis and can be accessed, although there are limitations in the application process. Primary-care data are recorded by a number of organisations on a de-identified basis but access for specific individuals has not been feasible. Access to data recorded by non-clinical sources, including The Department for Work and Pensions and The Driving and Vehicle Licensing Agency, was not successful. Recommendations discussed include further research to assess the attributes of routinely recorded data, an assessment of public perceptions and the development of strategies to collaboratively improve access to

  3. [Diagnostic imaging of urolithiais. Current recommendations and new developments].

    PubMed

    Thalgott, M; Kurtz, F; Gschwend, J E; Straub, M

    2015-07-01

    Prevalence of urolithiasis is increasing in industrialized countries--in both adults and children, representing a unique diagnostic and therapeutic challenge. Risk-adapted diagnostic imaging currently means assessment with maximized sensitivity and specificity together with minimal radiation exposure. In clinical routine, imaging is performed by sonography, unenhanced computed tomography (NCCT) or intravenous urography (IVU) as well as plain kidney-ureter-bladder (KUB) radiographs. The aim of the present review is a critical guideline-based and therapy-aligned presentation of diagnostic imaging procedures for optimized treatment of urolithiasis considering the specifics in children and pregnant women.

  4. Vision 20/20: perspectives on automated image segmentation for radiotherapy.

    PubMed

    Sharp, Gregory; Fritscher, Karl D; Pekar, Vladimir; Peroni, Marta; Shusharina, Nadya; Veeraraghavan, Harini; Yang, Jinzhong

    2014-05-01

    Due to rapid advances in radiation therapy (RT), especially image guidance and treatment adaptation, a fast and accurate segmentation of medical images is a very important part of the treatment. Manual delineation of target volumes and organs at risk is still the standard routine for most clinics, even though it is time consuming and prone to intra- and interobserver variations. Automated segmentation methods seek to reduce delineation workload and unify the organ boundary definition. In this paper, the authors review the current autosegmentation methods particularly relevant for applications in RT. The authors outline the methods' strengths and limitations and propose strategies that could lead to wider acceptance of autosegmentation in routine clinical practice. The authors conclude that currently, autosegmentation technology in RT planning is an efficient tool for the clinicians to provide them with a good starting point for review and adjustment. Modern hardware platforms including GPUs allow most of the autosegmentation tasks to be done in a range of a few minutes. In the nearest future, improvements in CT-based autosegmentation tools will be achieved through standardization of imaging and contouring protocols. In the longer term, the authors expect a wider use of multimodality approaches and better understanding of correlation of imaging with biology and pathology.

  5. Vision 20/20: Perspectives on automated image segmentation for radiotherapy

    PubMed Central

    Sharp, Gregory; Fritscher, Karl D.; Pekar, Vladimir; Peroni, Marta; Shusharina, Nadya; Veeraraghavan, Harini; Yang, Jinzhong

    2014-01-01

    Due to rapid advances in radiation therapy (RT), especially image guidance and treatment adaptation, a fast and accurate segmentation of medical images is a very important part of the treatment. Manual delineation of target volumes and organs at risk is still the standard routine for most clinics, even though it is time consuming and prone to intra- and interobserver variations. Automated segmentation methods seek to reduce delineation workload and unify the organ boundary definition. In this paper, the authors review the current autosegmentation methods particularly relevant for applications in RT. The authors outline the methods’ strengths and limitations and propose strategies that could lead to wider acceptance of autosegmentation in routine clinical practice. The authors conclude that currently, autosegmentation technology in RT planning is an efficient tool for the clinicians to provide them with a good starting point for review and adjustment. Modern hardware platforms including GPUs allow most of the autosegmentation tasks to be done in a range of a few minutes. In the nearest future, improvements in CT-based autosegmentation tools will be achieved through standardization of imaging and contouring protocols. In the longer term, the authors expect a wider use of multimodality approaches and better understanding of correlation of imaging with biology and pathology. PMID:24784366

  6. How does routinely delivered cognitive-behavioural therapy for gambling disorder compare to "gold standard" clinical trial?

    PubMed

    Smith, David P; Fairweather-Schmidt, A Kate; Harvey, Peter W; Battersby, Malcolm W

    2018-03-01

    Currently, it is unknown whether treatment outcomes derived from randomized controlled trials (RCTs) of cognitive-behavioural therapy (CBT) for problem gamblers still hold when applied to patients seen in routine practice. Thus, data from an RCT of cognitive therapy versus exposure therapy for problem gambling versus patients of a gambling help service were compared. Assessments of problem gambling severity, psychosocial impairment, and alcohol use were undertaken at baseline and post-treatment and evaluated within a counterfactual framework. Findings showed that the contrast between routine CBT for pokies and horse betting had a significant effect, indicative of a 62% lower gambling urge score if routine CBT recipients had all been horse/track betters opposed to gambling with "pokies." However, the majority of contrasts indicated therapeutic outcomes achieved in routine CBT treatments were of equivalent robustness relative to RCT conditions. The present findings infer routine practice treatment outcomes are as efficacious as those generated in RCT contexts. Copyright © 2017 John Wiley & Sons, Ltd.

  7. [Is 3'-deoxy-3'- [18F] fluorothymidine ([18F]-FLT) the next tracer for routine clinical PET after R [18F]-FDG?].

    PubMed

    Couturier, Olivier; Leost, Françoise; Campone, Mario; Carlier, Thomas; Chatal, Jean-François; Hustinx, Roland

    2005-09-01

    Positron emission tomography (PET) with [18F]-FDG is now firmly established as a clinical tool in oncology. Its applications are however limited in some indications, due to the lack of specificity of its uptake mechanism for tumors, or the low avidity of some cancer types such as prostate. Alternative tracers are thus being developed, in order to fill up this void. Proliferation as a biological target is particularly attractive in cancer imaging. From that perspective, fluorothymidine ([18F]-FLT or FLT) has generated a strong interest among the scientific community, especially since the radiosynthesis process has been improved and simplified, thus making possible to envision a routine use for the tracer. This article aims at summarizing the status of the current scientific data regarding FLT. The uptake mechanism of FLT is well known, relying on the thymidine kinase 1 (TK1) enzymatic activity, and thus on DNA synthesis. Preclinical studies have shown a clear relationship between tracer accumulation and level of tumor proliferation, even though DNA salvage pathwayss intervene in the process and may complicate the interpretation of the results. Several clinical studies suggest a good specificity for tumor, albeit with a lower sensitivity than with FDG. In all likelihood however, the future of FLT lies in the evaluation of antitumor response and possibly the pretherapeutic prognostic characterization, rather than in the diagnosis and staging of malignancies. Although the scientific data regarding this issue remain limited, initial results are encouraging. Further significant work remains to be done in order to fully assess the clinical performances of the tracer, on the one hand, and to determine its place relative to FDG and other emerging tracers, on the other hand. Until these studies are completed, FLT should be considered as a promising tracer, but remaining at an experimental stage of its development.

  8. Molecular imaging using light-absorbing imaging agents and a clinical optical breast imaging system--a phantom study.

    PubMed

    van de Ven, Stephanie M W Y; Mincu, Niculae; Brunette, Jean; Ma, Guobin; Khayat, Mario; Ikeda, Debra M; Gambhir, Sanjiv S

    2011-04-01

    The aim of the study was to determine the feasibility of using a clinical optical breast scanner with molecular imaging strategies based on modulating light transmission. Different concentrations of single-walled carbon nanotubes (SWNT; 0.8-20.0 nM) and black hole quencher-3 (BHQ-3; 2.0-32.0 µM) were studied in specifically designed phantoms (200-1,570 mm(3)) with a clinical optical breast scanner using four wavelengths. Each phantom was placed in the scanner tank filled with optical matching medium. Background scans were compared to absorption scans, and reproducibility was assessed. All SWNT phantoms were detected at four wavelengths, with best results at 684 nm. Higher concentrations (≥8.0 µM) were needed for BHQ-3 detection, with the largest contrast at 684 nm. The optical absorption signal was dependent on phantom size and concentration. Reproducibility was excellent (intraclass correlation 0.93-0.98). Nanomolar concentrations of SWNT and micromolar concentrations of BHQ-3 in phantoms were reproducibly detected, showing the potential of light absorbers, with appropriate targeting ligands, as molecular imaging agents for clinical optical breast imaging.

  9. Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware.

    PubMed

    Vande Berg, Bruno; Malghem, Jacques; Maldague, Baudouin; Lecouvet, Frederic

    2006-12-01

    Multi-detector CT imaging (MDCT) becomes routine imaging modality in the assessment of the postoperative orthopedic patients with metallic instrumentation that degrades image quality at MR imaging. This article reviews the physical basis and CT appearance of such metal-related artifacts. It also addresses the clinical value of MDCT in postoperative orthopedic patients with emphasis on fracture healing, spinal fusion or arthrodesis, and joint replacement. MDCT imaging shows limitations in the assessment of the bone marrow cavity and of the soft tissues for which MR imaging remains the imaging modality of choice despite metal-related anatomic distortions and signal alteration.

  10. Technology-enabled examinations of cardiac rhythm, optic nerve, oral health, tympanic membrane, gait and coordination evaluated jointly with routine health screenings: an observational study at the 2015 Kumbh Mela in India

    PubMed Central

    Gupta, Otkrist; Patalano II, Vincent; Mohit, Mrinal; Merchant, Rikin; Subramanian, S V

    2018-01-01

    Objectives Technology-enabled non-invasive diagnostic screening (TES) using smartphones and other point-of-care medical devices was evaluated in conjunction with conventional routine health screenings for the primary care screening of patients. Design Dental conditions, cardiac ECG arrhythmias, tympanic membrane disorders, blood oxygenation levels, optic nerve disorders and neurological fitness were evaluated using FDA-approved advanced smartphone powered technologies. Routine health screenings were also conducted. A novel remote web platform was developed to allow expert physicians to examine TES data and compare efficacy with routine health screenings. Setting The study was conducted at a primary care centre during the 2015 Kumbh Mela in Maharashtra, India. Participants 494 consenting 18–90 years old adults attending the 2015 Kumbh Mela were tested. Results TES and routine health screenings identified unique clinical conditions in distinct patients. Intraoral fluorescent imaging classified 63.3% of the population with dental caries and periodontal diseases. An association between poor oral health and cardiovascular illnesses was also identified. Tympanic membrane imaging detected eardrum abnormalities in 13.0% of the population, several with a medical history of hearing difficulties. Gait and coordination issues were discovered in eight subjects and one subject had arrhythmia. Cross-correlations were observed between low oxygen saturation and low body mass index (BMI) with smokers (p=0.0087 and p=0.0122, respectively), and high BMI was associated with elevated blood pressure in middle-aged subjects. Conclusions TES synergistically identified clinically significant abnormalities in several subjects who otherwise presented as normal in routine health screenings. Physicians validated TES findings and used routine health screening data and medical history responses for comprehensive diagnoses for at-risk patients. TES identified high prevalence of oral diseases

  11. The young adult Strengths and Difficulties Questionnaire (SDQ) in routine clinical practice.

    PubMed

    Brann, Peter; Lethbridge, Melissa J; Mildred, Helen

    2018-06-01

    Expansion of the youth mental health sector has exposed a need for an outcome measure for young adults accessing services. The Strengths and Difficulties Questionnaire (SDQ) is a widely used consumer and carer outcome measure for children and adolescents. The aim of this study was to evaluate the psychometric properties of a young adult SDQ. The young adult SDQ was introduced for routine clinical practice at Eastern Health Child and Youth Mental Health Service (EH-CYMHS), complementing the well-established adolescent and child versions. Data for adolescents (aged 12-17) and young adults (aged 18-25) where both self-report and parent SDQs had been completed at entry point to the service were extracted from a two-year period. Overall, paired cases involved 532 adolescents and 125 young adults. Across both self-report and parent SDQs, a similar pattern of results was found between adolescents and young adults on mean scores, inter-scale correlations, internal consistency, and inter-rater agreement. The findings of the current study support the use of the young adult SDQ in public mental health as an instrument whose psychometric properties, to date, appear consistent with those of the adolescent version. Further investigation is warranted. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Visual acuity and central retinal thickness: fulfilment of retreatment criteria for recurrent neovascular AMD in routine clinical care.

    PubMed

    Reznicek, Lukas; Muhr, Johanna; Ulbig, Michael; Kampik, Anselm; Mayer, Wolfgang J; Haritoglou, Christos; Neubauer, Aljoscha; Wolf, Armin

    2014-10-01

    To evaluate the fulfillment of retreatment criteria in recurrent neovascular age-related macular degeneration (nAMD) for a pro-re-nata treatment regime with ranibizumab in routine clinical care. Data from patients with treatment-naive nAMD were analysed retrospectively. As an 'upload', all patients had received three-monthly intravitreal ranibizumab injections in a university eye hospital and were then seen by ophthalmologists in private practice who referred them back in case of recurrence. Recurrence was defined as a decrease of visual acuity (VA) of one line or more (functional retreatment criteria), a central retinal thickness (CRT) increase of at least 100 µm upon Optical Coherence Tomography (OCT) examination (morphological retreatment criteria) or a new macular haemorrhage (clinical retreatment criteria). We included 92 patients (36 men and 56 women). The mean VA before retreatment of a recurrence was -0.63 ± 0.33 logMAR and improved significantly (p<0.001) by 0.10 ± 0.16 logMAR to -0.53 ± 0.28 logMAR thereafter. Mean CRT before retreatment was 278.07 ± 87.56 µm and decreased significantly (p<0.001) by 71.22 ± 106.93 to 206.85 ± 60.30 µm. Evaluation of the fulfillment of retreatment criteria revealed functional retreatment criteria in 82.6% of patients. However, upon re-evaluation of VA using Early Treatment Diabetic Retinopathy Study (ETDRS) charts in the treatment centre, mean decrease of VA was 10 letters as compared with the end of upload therapy. All patients presented an increased CRT when treated for recurrence of nAMD (mean increase 69.47 µm), but the morphological retreatment criteria (CRT increase of 100 µm or more) were fulfilled in only 44.4% of patients upon Spectral Domain OCT (SD-OCT) evaluation in the treatment centre. In a routine clinical care, evaluation of VA using ETDRS charts seems to be more sensitive than Snellen VA testing. Quantitative OCT-based retreatment criteria (eg, increase of CRT of 100 µm or more) appear to be

  13. Automatic lumbar spine measurement in CT images

    NASA Astrophysics Data System (ADS)

    Mao, Yunxiang; Zheng, Dong; Liao, Shu; Peng, Zhigang; Yan, Ruyi; Liu, Junhua; Dong, Zhongxing; Gong, Liyan; Zhou, Xiang Sean; Zhan, Yiqiang; Fei, Jun

    2017-03-01

    Accurate lumbar spine measurement in CT images provides an essential way for quantitative spinal diseases analysis such as spondylolisthesis and scoliosis. In today's clinical workflow, the measurements are manually performed by radiologists and surgeons, which is time consuming and irreproducible. Therefore, automatic and accurate lumbar spine measurement algorithm becomes highly desirable. In this study, we propose a method to automatically calculate five different lumbar spine measurements in CT images. There are three main stages of the proposed method: First, a learning based spine labeling method, which integrates both the image appearance and spine geometry information, is used to detect lumbar and sacrum vertebrae in CT images. Then, a multiatlases based image segmentation method is used to segment each lumbar vertebra and the sacrum based on the detection result. Finally, measurements are derived from the segmentation result of each vertebra. Our method has been evaluated on 138 spinal CT scans to automatically calculate five widely used clinical spine measurements. Experimental results show that our method can achieve more than 90% success rates across all the measurements. Our method also significantly improves the measurement efficiency compared to manual measurements. Besides benefiting the routine clinical diagnosis of spinal diseases, our method also enables the large scale data analytics for scientific and clinical researches.

  14. [Use of PubMed to improve evidence-based medicine in routine urological practice].

    PubMed

    Rink, M; Kluth, L A; Shariat, S F; Chun, F K; Fisch, M; Dahm, P

    2013-03-01

    Applying evidence-based medicine in daily clinical practice is the basis of patient-centered medicine and knowledge of accurate literature acquisition skills is necessary for informed clinical decision-making. PubMed is an easy accessible, free bibliographic database comprising over 21 million citations from the medical field, life-science journals and online books. The article summarizes the effective use of PubMed in routine urological clinical practice based on a common case scenario. This article explains the simple use of PubMed to obtain the best search results with the highest evidence. Accurate knowledge about the use of PubMed in routine clinical practice can improve evidence-based medicine and also patient treatment.

  15. Infrared Imaging; A casebook in clinical medicine

    NASA Astrophysics Data System (ADS)

    Ring, Francis

    2015-09-01

    Infrared thermal imaging is a rapid and non-invasive procedure for mapping skin temperature distribution of the human body. Advanced software and high-resolution infrared detectors has allowed for a renaissance in the use of infrared thermal imaging or thermography in medical research and practice. After a review of theory, technology and methodology of medical infrared imaging, the remainder of the book consists of a collection of clinical case studies demonstrating the wide variety of applications of thermography in modern medicine. The combined expertise from a number of centres is used to create this database of images and cases that will be invaluable for medical researchers and practitioners in making diagnoses and measuring treatment efficacy. This book is recommended reading for practising and training radiographers, medical physicists and clinicians.

  16. Multispectral photoacoustic imaging of nerves with a clinical ultrasound system

    NASA Astrophysics Data System (ADS)

    Mari, Jean Martial; West, Simeon; Beard, Paul C.; Desjardins, Adrien E.

    2014-03-01

    Accurate and efficient identification of nerves is of great importance during many ultrasound-guided clinical procedures, including nerve blocks and prostate biopsies. It can be challenging to visualise nerves with conventional ultrasound imaging, however. One of the challenges is that nerves can have very similar appearances to nearby structures such as tendons. Several recent studies have highlighted the potential of near-infrared optical spectroscopy for differentiating nerves and adjacent tissues, as this modality can be sensitive to optical absorption of lipids that are present in intra- and extra-neural adipose tissue and in the myelin sheaths. These studies were limited to point measurements, however. In this pilot study, a custom photoacoustic system with a clinical ultrasound imaging probe was used to acquire multi-spectral photoacoustic images of nerves and tendons from swine ex vivo, across the wavelength range of 1100 to 1300 nm. Photoacoustic images were processed and overlaid in colour onto co-registered conventional ultrasound images that were acquired with the same imaging probe. A pronounced optical absorption peak centred at 1210 nm was observed in the photoacoustic signals obtained from nerves, and it was absent in those obtained from tendons. This absorption peak, which is consistent with the presence of lipids, provides a novel image contrast mechanism to significantly enhance the visualization of nerves. In particular, image contrast for nerves was up to 5.5 times greater with photoacoustic imaging (0.82 +/- 0.15) than with conventional ultrasound imaging (0.148 +/- 0.002), with a maximum contrast of 0.95 +/- 0.02 obtained in photoacoustic mode. This pilot study demonstrates the potential of photoacoustic imaging to improve clinical outcomes in ultrasound-guided interventions in regional anaesthesia and interventional oncology.

  17. Integrated clinical workstations for image and text data capture, display, and teleconsultation.

    PubMed Central

    Dayhoff, R.; Kuzmak, P. M.; Kirin, G.

    1994-01-01

    The Department of Veterans Affairs (VA) DHCP Imaging System digitally records clinically significant diagnostic images selected by medical specialists in a variety of hospital departments, including radiology, cardiology, gastroenterology, pathology, dermatology, hematology, surgery, podiatry, dental clinic, and emergency room. These images, which include true color and gray scale images, scanned documents, and electrocardiogram waveforms, are stored on network file servers and displayed on workstations located throughout a medical center. All images are managed by the VA's hospital information system (HIS), allowing integrated displays of text and image data from all medical specialties. Two VA medical centers currently have DHCP Imaging Systems installed, and other installations are underway. PMID:7949899

  18. Integrated clinical workstations for image and text data capture, display, and teleconsultation.

    PubMed

    Dayhoff, R; Kuzmak, P M; Kirin, G

    1994-01-01

    The Department of Veterans Affairs (VA) DHCP Imaging System digitally records clinically significant diagnostic images selected by medical specialists in a variety of hospital departments, including radiology, cardiology, gastroenterology, pathology, dermatology, hematology, surgery, podiatry, dental clinic, and emergency room. These images, which include true color and gray scale images, scanned documents, and electrocardiogram waveforms, are stored on network file servers and displayed on workstations located throughout a medical center. All images are managed by the VA's hospital information system (HIS), allowing integrated displays of text and image data from all medical specialties. Two VA medical centers currently have DHCP Imaging Systems installed, and other installations are underway.

  19. Normal feline brain: clinical anatomy using magnetic resonance imaging.

    PubMed

    Mogicato, G; Conchou, F; Layssol-Lamour, C; Raharison, F; Sautet, J

    2012-04-01

    The purpose of this study was to provide a clinical anatomy atlas of the feline brain using magnetic resonance imaging (MRI). Brains of twelve normal cats were imaged using a 1.5 T magnetic resonance unit and an inversion/recovery sequence (T1). Fourteen relevant MRI sections were chosen in transverse, dorsal, median and sagittal planes. Anatomic structures were identified and labelled using anatomical texts and Nomina Anatomica Veterinaria, sectioned specimen heads, and previously published articles. The MRI sections were stained according to the major embryological and anatomical subdivisions of the brain. The relevant anatomical structures seen on MRI will assist clinicians to better understand MR images and to relate this neuro-anatomy to clinical signs. © 2011 Blackwell Verlag GmbH.

  20. Shortwave infrared fluorescence imaging with the clinically approved near-infrared dye indocyanine green.

    PubMed

    Carr, Jessica A; Franke, Daniel; Caram, Justin R; Perkinson, Collin F; Saif, Mari; Askoxylakis, Vasileios; Datta, Meenal; Fukumura, Dai; Jain, Rakesh K; Bawendi, Moungi G; Bruns, Oliver T

    2018-04-24

    Fluorescence imaging is a method of real-time molecular tracking in vivo that has enabled many clinical technologies. Imaging in the shortwave IR (SWIR; 1,000-2,000 nm) promises higher contrast, sensitivity, and penetration depths compared with conventional visible and near-IR (NIR) fluorescence imaging. However, adoption of SWIR imaging in clinical settings has been limited, partially due to the absence of US Food and Drug Administration (FDA)-approved fluorophores with peak emission in the SWIR. Here, we show that commercially available NIR dyes, including the FDA-approved contrast agent indocyanine green (ICG), exhibit optical properties suitable for in vivo SWIR fluorescence imaging. Even though their emission spectra peak in the NIR, these dyes outperform commercial SWIR fluorophores and can be imaged in the SWIR, even beyond 1,500 nm. We show real-time fluorescence imaging using ICG at clinically relevant doses, including intravital microscopy, noninvasive imaging in blood and lymph vessels, and imaging of hepatobiliary clearance, and show increased contrast compared with NIR fluorescence imaging. Furthermore, we show tumor-targeted SWIR imaging with IRDye 800CW-labeled trastuzumab, an NIR dye being tested in multiple clinical trials. Our findings suggest that high-contrast SWIR fluorescence imaging can be implemented alongside existing imaging modalities by switching the detection of conventional NIR fluorescence systems from silicon-based NIR cameras to emerging indium gallium arsenide-based SWIR cameras. Using ICG in particular opens the possibility of translating SWIR fluorescence imaging to human clinical applications. Indeed, our findings suggest that emerging SWIR-fluorescent in vivo contrast agents should be benchmarked against the SWIR emission of ICG in blood.

  1. Quadruple Inversion-Recovery b-SSFP MRA of the Abdomen: Initial Clinical Validation

    PubMed Central

    Atanasova, Iliyana P.; Lim, Ruth P.; Chandarana, Hersh; Storey, Pippa; Bruno, Mary T; Kim, Daniel; Lee, Vivian S.

    2014-01-01

    The purpose of this study is to assess the image quality and diagnostic accuracy of non-contrast quadruple inversion-recovery balanced-SSFP MRA (QIR MRA) for detection of aortoiliac disease in a clinical population. QIR MRA was performed in 26 patients referred for routine clinical gadolinium-enhanced MRA (Gd-MRA) for known or suspected aortoiliac disease. Non-contrast images were independently evaluated for image qualityand degree of stenosisby two radiologists, usingconsensus Gd-MRA as the reference standard. Hemodynamically significant stenosis (≥ 50%) was found in 10% (22/226) of all evaluable segments on Gd-MRA. The sensitivity and specificity for stenosis evaluation by QIR MRA for the two readers were 86%/86% and 95%/93% respectively. Negative predictive value and positive predictive value were 98%/98% and 63%/53% respectively. For stenosis evaluation of the aortoiliac region QIR MRA showed good agreement with the reference standard with high negative predictive value and a tendency to overestimate mild disease presumably due to the flow-dependence of the technique. QIR MRA could be a reasonable alternative to Gd-MRA for ruling out stenosis when contrast is contraindicated due to impaired kidney function or in patients who undergo abdominal MRA for screening purposes. Further work is necessary to improve performance and justify routine clinical use. PMID:24998363

  2. Reproducibility of radiomics for deciphering tumor phenotype with imaging

    NASA Astrophysics Data System (ADS)

    Zhao, Binsheng; Tan, Yongqiang; Tsai, Wei-Yann; Qi, Jing; Xie, Chuanmiao; Lu, Lin; Schwartz, Lawrence H.

    2016-03-01

    Radiomics (radiogenomics) characterizes tumor phenotypes based on quantitative image features derived from routine radiologic imaging to improve cancer diagnosis, prognosis, prediction and response to therapy. Although radiomic features must be reproducible to qualify as biomarkers for clinical care, little is known about how routine imaging acquisition techniques/parameters affect reproducibility. To begin to fill this knowledge gap, we assessed the reproducibility of a comprehensive, commonly-used set of radiomic features using a unique, same-day repeat computed tomography data set from lung cancer patients. Each scan was reconstructed at 6 imaging settings, varying slice thicknesses (1.25 mm, 2.5 mm and 5 mm) and reconstruction algorithms (sharp, smooth). Reproducibility was assessed using the repeat scans reconstructed at identical imaging setting (6 settings in total). In separate analyses, we explored differences in radiomic features due to different imaging parameters by assessing the agreement of these radiomic features extracted from the repeat scans reconstructed at the same slice thickness but different algorithms (3 settings in total). Our data suggest that radiomic features are reproducible over a wide range of imaging settings. However, smooth and sharp reconstruction algorithms should not be used interchangeably. These findings will raise awareness of the importance of properly setting imaging acquisition parameters in radiomics/radiogenomics research.

  3. Clinical potential for imaging in patients with asthma and other lung disorders.

    PubMed

    DeBoer, Emily M; Spielberg, David R; Brody, Alan S

    2017-01-01

    The ability of lung imaging to phenotype patients, determine prognosis, and predict response to treatment is expanding in clinical and translational research. The purpose of this perspective is to describe current imaging modalities that might be useful clinical tools in patients with asthma and other lung disorders and to explore some of the new developments in imaging modalities of the lung. These imaging modalities include chest radiography, computed tomography, lung magnetic resonance imaging, electrical impedance tomography, bronchoscopy, and others. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  4. Microbiology and Biofilm Trends of Silicone Lacrimal Implants: Comparing Infected Versus Routinely Removed Stents.

    PubMed

    Samimi, David B; Ediriwickrema, Lilangi S; Bielory, Brett P; Miller, Darlene; Lee, Wendy; Johnson, Thomas E

    To investigate the pathogens and biofilms responsible for clinically significant infection of silicone stents implanted within the lacrimal system. Retrospective review of culture results and patient demographics for all silicone lacrimal stents removed early for clinically significant infection and sent to the Bascom Palmer Microbiology Laboratory through the end of year 2010. As a control, routinely removed, clinically noninfected stents from the same institution were prospectively sent for culture over a 6-month period. Four clinically infected and 6 clinically noninfected stents showing mucus within the lumen at removal were sent for scanning electron microscopy. Images were randomized and graded by a microbiologist for the presence of organisms, matrix deposits, organisms within matrix, and overall impression of significant biofilm formation. Nineteen stents were included in the study; 100% of clinically infected (n = 10) and noninfected (n = 9) stents were culture positive. Culture positivity for nontuberculous mycobacterium was found in 90% of infected stents and none of the noninfected stents (p < 0.001). Of infected stents, 50% grew Gram-positive organisms compared with 89% of noninfected stents (p = 0.07). Fifty percent of infected versus 67% of noninfected stents were culture positive for Gram-negative organisms (p = 0.46). Electron microscopy of stents revealed organisms consistent with culture results (size, shape) in planktonic and biofilm form. Masked observer image grading revealed a statistically significant higher amount of organism and biofilm on infected versus noninfected specimen. Nontuberculous mycobacteria comprise the primary pathogens responsible for clinically significant infection of silicone stents in the lacrimal system in South Florida. Robust biofilm production by this organism likely plays a role in pathogenesis. Further research into biofilm-related lacrimal implant infection may aid in the development of useful prevention and

  5. “There Are Too Many, but Never Enough": Qualitative Case Study Investigating Routine Coding of Clinical Information in Depression

    PubMed Central

    Cresswell, Kathrin; Morrison, Zoe; Sheikh, Aziz; Kalra, Dipak

    2012-01-01

    Background We sought to understand how clinical information relating to the management of depression is routinely coded in different clinical settings and the perspectives of and implications for different stakeholders with a view to understanding how these may be aligned. Materials and Methods Qualitative investigation exploring the views of a purposefully selected range of healthcare professionals, managers, and clinical coders spanning primary and secondary care. Results Our dataset comprised 28 semi-structured interviews, a focus group, documents relating to clinical coding standards and participant observation of clinical coding activities. We identified a range of approaches to coding clinical information including templates and order entry systems. The challenges inherent in clearly establishing a diagnosis, identifying appropriate clinical codes and possible implications of diagnoses for patients were particularly prominent in primary care. Although a range of managerial and research benefits were identified, there were no direct benefits from coded clinical data for patients or professionals. Secondary care staff emphasized the role of clinical coders in ensuring data quality, which was at odds with the policy drive to increase real-time clinical coding. Conclusions There was overall no evidence of clear-cut direct patient care benefits to inform immediate care decisions, even in primary care where data on patients with depression were more extensively coded. A number of important secondary uses were recognized by healthcare staff, but the coding of clinical data to serve these ends was often poorly aligned with clinical practice and patient-centered considerations. The current international drive to encourage clinical coding by healthcare professionals during the clinical encounter may need to be critically examined. PMID:22937106

  6. Clinical value of selective serial sectioning of laryngectomy specimens.

    PubMed Central

    Browning, G. G.

    1976-01-01

    A simple routine pathology method for examining laryngectomy specimens has been presented which (1) gives the clinician information regarding the probability of total excision of the tumour; (2) allows more accurate staging of laryngeal tumours; (3) will act as a basis for evaluation of preoperative investigations and future clinical trials of treatment. Images Fig 1 Fig 2 PMID:785476

  7. [Evaluating the maturity of IT-supported clinical imaging and diagnosis using the Digital Imaging Adoption Model : Are your clinical imaging processes ready for the digital era?

    PubMed

    Studzinski, J

    2017-06-01

    The Digital Imaging Adoption Model (DIAM) has been jointly developed by HIMSS Analytics and the European Society of Radiology (ESR). It helps evaluate the maturity of IT-supported processes in medical imaging, particularly in radiology. This eight-stage maturity model drives your organisational, strategic and tactical alignment towards imaging-IT planning. The key audience for the model comprises hospitals with imaging centers, as well as external imaging centers that collaborate with hospitals. The assessment focuses on different dimensions relevant to digital imaging, such as software infrastructure and usage, workflow security, clinical documentation and decision support, data exchange and analytical capabilities. With its standardised approach, it enables regional, national and international benchmarking. All DIAM participants receive a structured report that can be used as a basis for presenting, e.g. budget planning and investment decisions at management level.

  8. [Magnetic Resonance Imaging Conversion Predictors of Clinically Isolated Syndrome to Multiple Sclerosis].

    PubMed

    Peixoto, Sara; Abreu, Pedro

    2016-11-01

    Clinically isolated syndrome may be the first manifestation of multiple sclerosis, a chronic demyelinating disease of the central nervous system, and it is defined by a single clinical episode suggestive of demyelination. However, patients with this syndrome, even with long term follow up, may not develop new symptoms or demyelinating lesions that fulfils multiple sclerosis diagnostic criteria. We reviewed, in clinically isolated syndrome, what are the best magnetic resonance imaging findings that may predict its conversion to multiple sclerosis. A search was made in the PubMed database for papers published between January 2010 and June 2015 using the following terms: 'clinically isolated syndrome', 'cis', 'multiple sclerosis', 'magnetic resonance imaging', 'magnetic resonance' and 'mri'. In this review, the following conventional magnetic resonance imaging abnormalities found in literature were included: lesion load, lesion location, Barkhof's criteria and brain atrophy related features. The non conventional magnetic resonance imaging techniques studied were double inversion recovery, magnetization transfer imaging, spectroscopy and diffusion tensor imaging. The number and location of demyelinating lesions have a clear role in predicting clinically isolated syndrome conversion to multiple sclerosis. On the other hand, more data are needed to confirm the ability to predict this disease development of non conventional techniques and remaining neuroimaging abnormalities. In forthcoming years, in addition to the established predictive value of the above mentioned neuroimaging abnormalities, different clinically isolated syndrome neuroradiological findings may be considered in multiple sclerosis diagnostic criteria and/or change its treatment recommendations.

  9. Clinical feasibility of simultaneous multi-slice imaging with blipped-CAIPI for diffusion-weighted imaging and diffusion-tensor imaging of the brain.

    PubMed

    Yokota, Hajime; Sakai, Koji; Tazoe, Jun; Goto, Mariko; Imai, Hiroshi; Teramukai, Satoshi; Yamada, Kei

    2017-12-01

    Background Simultaneous multi-slice (SMS) imaging is starting to be used in clinical situation, although evidence of clinical feasibility is scanty. Purpose To prospectively assess the clinical feasibility of SMS diffusion-weighted imaging (DWI) and diffusion-tensor imaging (DTI) with blipped-controlled aliasing in parallel imaging for brain lesions. Material and Methods The institutional review board approved this study. This study included 156 hyperintense lesions on DWI from 32 patients. A slice acceleration factor of 2 was applied for SMS scans, which allowed shortening of the scan time by 41.3%. The signal-to-noise ratio (SNR) was calculated for brain tissue of a selected slice. The contrast-to-noise ratio (CNR), apparent diffusion coefficient (ADC), and fractional anisotropy (FA) were calculated in 36 hyperintense lesions with a diameter of three pixels or more. Visual assessment was performed for all 156 lesions. Tractography of the corticospinal tract of 29 patients was evaluated. The number of tracts and averaged tract length were used for quantitative analysis, and visual assessment was evaluated by grading. Results The SMS scan showed no bias and acceptable 95% limits of agreement compared to conventional scans in SNR, CNR, and ADC on Bland-Altman analyses. Only FA of the lesions was higher in the SMS scan by 9% ( P = 0.016), whereas FA of the surrounding tissues was similar. Quantitative analysis of tractography showed similar values. Visual assessment of DWI hyperintense lesions and tractography also resulted in comparable evaluation. Conclusion SMS imaging was clinically feasible for imaging quality and quantitative values compared with conventional DWI and DTI.

  10. Adaptive optics retinal imaging: emerging clinical applications.

    PubMed

    Godara, Pooja; Dubis, Adam M; Roorda, Austin; Duncan, Jacque L; Carroll, Joseph

    2010-12-01

    The human retina is a uniquely accessible tissue. Tools like scanning laser ophthalmoscopy and spectral domain-optical coherence tomography provide clinicians with remarkably clear pictures of the living retina. Although the anterior optics of the eye permit such non-invasive visualization of the retina and associated pathology, the same optics induce significant aberrations that obviate cellular-resolution imaging in most cases. Adaptive optics (AO) imaging systems use active optical elements to compensate for aberrations in the optical path between the object and the camera. When applied to the human eye, AO allows direct visualization of individual rod and cone photoreceptor cells, retinal pigment epithelium cells, and white blood cells. AO imaging has changed the way vision scientists and ophthalmologists see the retina, helping to clarify our understanding of retinal structure, function, and the etiology of various retinal pathologies. Here, we review some of the advances that were made possible with AO imaging of the human retina and discuss applications and future prospects for clinical imaging.

  11. Hybrid imaging in foot and ankle disorders.

    PubMed

    García Jiménez, R; García-Gómez, F J; Noriega Álvarez, E; Calvo Morón, C; Martín-Marcuartu, J J

    Disorders of the foot and ankle are some of the most frequent ones affecting the musculoskeletal system and have a great impact on patients' quality of life. Accurate diagnosis is an important clinical challenge because of the complex anatomy and function of the foot, that make it difficult to locate the source of the pain by routine clinical examination. In the study of foot pathology, anatomical imaging (radiography, magnetic resonance imaging [MRI], ultrasound and computed tomography [CT]) and functional imaging (bone scan, positron emission tomography [PET] and MRI) techniques have been used. Hybrid imaging combines the advantages of morphological and functional studies in a synergistic way, helping the clinician manage complex problems. In this article we delve into the anatomy and biomechanics of the foot and ankle and describe the potential indications for the current hybrid techniques available for the study of foot and ankle disease. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  12. Update on wide- and ultra-widefield retinal imaging

    PubMed Central

    Shoughy, Samir S; Arevalo, J Fernando; Kozak, Igor

    2015-01-01

    The peripheral retina is the site of pathology in many ocular diseases and ultra-widefield (UWF) imaging is one of the new technologies available to ophthalmologists to manage some of these diseases. Currently, there are several imaging systems used in practice for the purpose of diagnostic, monitoring disease progression or response to therapy, and telemedicine. These include modalities for both adults and pediatric patients. The current systems are capable of producing wide- and UWF color fundus photographs, fluorescein and indocyanine green angiograms, and autofluorescence images. Using this technology, important clinical observations have been made in diseases such as diabetic retinopathy, uveitides, retinal vascular occlusions and tumors, intraocular tumors, retinopathy of prematurity, and age-related macular degeneration. Widefield imaging offers excellent postoperative documentation of retinal detachment surgery. New applications will soon be available to integrate this technology into large volume routine clinical practice. PMID:26458474

  13. Quantitative analysis for peripheral vascularity assessment based on clinical photoacoustic and ultrasound images

    NASA Astrophysics Data System (ADS)

    Murakoshi, Dai; Hirota, Kazuhiro; Ishii, Hiroyasu; Hashimoto, Atsushi; Ebata, Tetsurou; Irisawa, Kaku; Wada, Takatsugu; Hayakawa, Toshiro; Itoh, Kenji; Ishihara, Miya

    2018-02-01

    Photoacoustic (PA) imaging technology is expected to be applied to clinical assessment for peripheral vascularity. We started a clinical evaluation with the prototype PA imaging system we recently developed. Prototype PA imaging system was composed with in-house Q-switched Alexandrite laser system which emits short-pulsed laser with 750 nm wavelength, handheld ultrasound transducer where illumination optics were integrated and signal processing for PA image reconstruction implemented in the clinical ultrasound (US) system. For the purpose of quantitative assessment of PA images, an image analyzing function has been developed and applied to clinical PA images. In this analyzing function, vascularity derived from PA signal intensity ranged for prescribed threshold was defined as a numerical index of vessel fulfillment and calculated for the prescribed region of interest (ROI). Skin surface was automatically detected by utilizing B-mode image acquired simultaneously with PA image. Skinsurface position is utilized to place the ROI objectively while avoiding unwanted signals such as artifacts which were imposed due to melanin pigment in the epidermal layer which absorbs laser emission and generates strong PA signals. Multiple images were available to support the scanned image set for 3D viewing. PA images for several fingers of patients with systemic sclerosis (SSc) were quantitatively assessed. Since the artifact region is trimmed off in PA images, the visibility of vessels with rather low PA signal intensity on the 3D projection image was enhanced and the reliability of the quantitative analysis was improved.

  14. Automatic classification and detection of clinically relevant images for diabetic retinopathy

    NASA Astrophysics Data System (ADS)

    Xu, Xinyu; Li, Baoxin

    2008-03-01

    We proposed a novel approach to automatic classification of Diabetic Retinopathy (DR) images and retrieval of clinically-relevant DR images from a database. Given a query image, our approach first classifies the image into one of the three categories: microaneurysm (MA), neovascularization (NV) and normal, and then it retrieves DR images that are clinically-relevant to the query image from an archival image database. In the classification stage, the query DR images are classified by the Multi-class Multiple-Instance Learning (McMIL) approach, where images are viewed as bags, each of which contains a number of instances corresponding to non-overlapping blocks, and each block is characterized by low-level features including color, texture, histogram of edge directions, and shape. McMIL first learns a collection of instance prototypes for each class that maximizes the Diverse Density function using Expectation- Maximization algorithm. A nonlinear mapping is then defined using the instance prototypes and maps every bag to a point in a new multi-class bag feature space. Finally a multi-class Support Vector Machine is trained in the multi-class bag feature space. In the retrieval stage, we retrieve images from the archival database who bear the same label with the query image, and who are the top K nearest neighbors of the query image in terms of similarity in the multi-class bag feature space. The classification approach achieves high classification accuracy, and the retrieval of clinically-relevant images not only facilitates utilization of the vast amount of hidden diagnostic knowledge in the database, but also improves the efficiency and accuracy of DR lesion diagnosis and assessment.

  15. Brand-to-generic levetiracetam switch in patients with epilepsy in a routine clinical setting.

    PubMed

    Markoula, Sofia; Chatzistefanidis, Dimitrios; Gatzonis, Stylianos; Siatouni, Anna; Siarava, Eleftheria; Verentzioti, Anastasia; Kyritsis, Athanassios P; Patsalos, Philip N

    2017-05-01

    The therapeutic equivalence of generic and brand antiepileptic drugs, based on studies performed on healthy volunteers, has been questioned. We compare, in a routine clinical setting, brand versus generic levetiracetam (LEV) bioequivalence in patients with epilepsy and also the clinical efficacy and tolerability of the substitution. A prospective, open-label, non-randomized, steady-state, multiple-dose, bioequivalence study was conducted in 12 patients with epilepsy (5 females), with a mean age of 38.4±16.2 years. Patients treated with the brand LEV (Keppra; UCB Pharma) were closely followed for a four-week period and subsequently switched to a generic LEV (Pharmaten) and followed for another four-week period. Blood samples were collected at the end of each 4-week period, during a dose interval for each formulation, for LEV concentration measurements by liquid chromatography mass spectrometry. Steady-state area under the curve (AUC) and peak plasma concentration (Cmax) data were subjected to conventional average bioequivalence analysis. Secondary clinical outcomes, including seizure frequency and adverse events, were recorded. Patients had epilepsy for a mean period of 14.1±10.6years and the mean daily LEV dose was 2583.3±763.7mg. The mean AUC±SD and Cmax±SD was 288.4±86.3(mg/L)h and 37.8±10.4mg/L respectively for brand LEV and 319.2±104.7(mg/L)h and 41.6±12.3mg/L respectively for the generic LEV. Statistic analysis showed no statistical significant difference in bioequivalence. Also, no change in seizures frequency and/or adverse events was recorded. In our clinical setting, generic LEV was determined to be bioequivalent to brand LEV. Furthermore, seizures frequency or/and adverse events were not affected upon switching from brand to generic LEV. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  16. Retrieving clinically relevant diabetic retinopathy images using a multi-class multiple-instance framework

    NASA Astrophysics Data System (ADS)

    Chandakkar, Parag S.; Venkatesan, Ragav; Li, Baoxin

    2013-02-01

    Diabetic retinopathy (DR) is a vision-threatening complication from diabetes mellitus, a medical condition that is rising globally. Unfortunately, many patients are unaware of this complication because of absence of symptoms. Regular screening of DR is necessary to detect the condition for timely treatment. Content-based image retrieval, using archived and diagnosed fundus (retinal) camera DR images can improve screening efficiency of DR. This content-based image retrieval study focuses on two DR clinical findings, microaneurysm and neovascularization, which are clinical signs of non-proliferative and proliferative diabetic retinopathy. The authors propose a multi-class multiple-instance image retrieval framework which deploys a modified color correlogram and statistics of steerable Gaussian Filter responses, for retrieving clinically relevant images from a database of DR fundus image database.

  17. Spectral imaging using clinical megavoltage beams and a novel multi-layer imager

    NASA Astrophysics Data System (ADS)

    Myronakis, Marios; Fueglistaller, Rony; Rottmann, Joerg; Hu, Yue-Houng; Wang, Adam; Baturin, Paul; Huber, Pascal; Morf, Daniel; Star-Lack, Josh; Berbeco, Ross

    2017-12-01

    We assess the feasibility of clinical megavoltage (MV) spectral imaging for material and bone separation with a novel multi-layer imager (MLI) prototype. The MLI provides higher detective quantum efficiency and lower noise than conventional electronic portal imagers. Simulated experiments were performed using a validated Monte Carlo model of the MLI to estimate energy absorption and energy separation between the MLI components. Material separation was evaluated experimentally using solid water and aluminum (Al), copper (Cu) and gold (Au) for 2.5 MV, 6 MV and 6 MV flattening filter free (FFF) clinical photon beams. An anthropomorphic phantom with implanted gold fiducials was utilized to further demonstrate bone/gold separation. Weighted subtraction imaging was employed for material and bone separation. The weighting factor (w) was iteratively estimated, with the optimal w value determined by minimization of the relative signal difference (Δ {{S}R} ) and signal-difference-to-noise ratio (SDNR) between material (or bone) and the background. Energy separation between layers of the MLI was mainly the result of beam hardening between components with an average energy separation between 34 and 47 keV depending on the x-ray beam energy. The minimum average energy of the detected spectrum in the phosphor layer was 123 keV in the top layer of the MLI with the 2.5 MV beam. The w values that minimized Δ {{S}R} and SDNR for Al, Cu and Au were 0.89, 0.76 and 0.64 for 2.5 MV; for 6 MV FFF, w was 0.98, 0.93 and 0.77 respectively. Bone suppression in the anthropomorphic phantom resulted in improved visibility of the gold fiducials with the 2.5 MV beam. Optimization of the MLI design is required to achieve optimal separation at clinical MV beam energies.

  18. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    PubMed

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  19. Cancer imaging phenomics toolkit: quantitative imaging analytics for precision diagnostics and predictive modeling of clinical outcome.

    PubMed

    Davatzikos, Christos; Rathore, Saima; Bakas, Spyridon; Pati, Sarthak; Bergman, Mark; Kalarot, Ratheesh; Sridharan, Patmaa; Gastounioti, Aimilia; Jahani, Nariman; Cohen, Eric; Akbari, Hamed; Tunc, Birkan; Doshi, Jimit; Parker, Drew; Hsieh, Michael; Sotiras, Aristeidis; Li, Hongming; Ou, Yangming; Doot, Robert K; Bilello, Michel; Fan, Yong; Shinohara, Russell T; Yushkevich, Paul; Verma, Ragini; Kontos, Despina

    2018-01-01

    The growth of multiparametric imaging protocols has paved the way for quantitative imaging phenotypes that predict treatment response and clinical outcome, reflect underlying cancer molecular characteristics and spatiotemporal heterogeneity, and can guide personalized treatment planning. This growth has underlined the need for efficient quantitative analytics to derive high-dimensional imaging signatures of diagnostic and predictive value in this emerging era of integrated precision diagnostics. This paper presents cancer imaging phenomics toolkit (CaPTk), a new and dynamically growing software platform for analysis of radiographic images of cancer, currently focusing on brain, breast, and lung cancer. CaPTk leverages the value of quantitative imaging analytics along with machine learning to derive phenotypic imaging signatures, based on two-level functionality. First, image analysis algorithms are used to extract comprehensive panels of diverse and complementary features, such as multiparametric intensity histogram distributions, texture, shape, kinetics, connectomics, and spatial patterns. At the second level, these quantitative imaging signatures are fed into multivariate machine learning models to produce diagnostic, prognostic, and predictive biomarkers. Results from clinical studies in three areas are shown: (i) computational neuro-oncology of brain gliomas for precision diagnostics, prediction of outcome, and treatment planning; (ii) prediction of treatment response for breast and lung cancer, and (iii) risk assessment for breast cancer.

  20. Workflow oriented software support for image guided radiofrequency ablation of focal liver malignancies

    NASA Astrophysics Data System (ADS)

    Weihusen, Andreas; Ritter, Felix; Kröger, Tim; Preusser, Tobias; Zidowitz, Stephan; Peitgen, Heinz-Otto

    2007-03-01

    Image guided radiofrequency (RF) ablation has taken a significant part in the clinical routine as a minimally invasive method for the treatment of focal liver malignancies. Medical imaging is used in all parts of the clinical workflow of an RF ablation, incorporating treatment planning, interventional targeting and result assessment. This paper describes a software application, which has been designed to support the RF ablation workflow under consideration of the requirements of clinical routine, such as easy user interaction and a high degree of robust and fast automatic procedures, in order to keep the physician from spending too much time at the computer. The application therefore provides a collection of specialized image processing and visualization methods for treatment planning and result assessment. The algorithms are adapted to CT as well as to MR imaging. The planning support contains semi-automatic methods for the segmentation of liver tumors and the surrounding vascular system as well as an interactive virtual positioning of RF applicators and a concluding numerical estimation of the achievable heat distribution. The assessment of the ablation result is supported by the segmentation of the coagulative necrosis and an interactive registration of pre- and post-interventional image data for the comparison of tumor and necrosis segmentation masks. An automatic quantification of surface distances is performed to verify the embedding of the tumor area into the thermal lesion area. The visualization methods support representations in the commonly used orthogonal 2D view as well as in 3D scenes.

  1. Use of imaging during symptomatic follow-up after resection of pancreatic ductal adenocarcinoma.

    PubMed

    Groot, Vincent P; Daamen, Lois A; Hagendoorn, Jeroen; Borel Rinkes, Inne H M; van Santvoort, Hjalmar C; Molenaar, I Quintus

    2018-01-01

    Controversy exists whether follow-up after resection of pancreatic ductal adenocarcinoma (PDAC) should include standardized imaging for the detection of disease recurrence. The purpose of this study was to evaluate how often patients undergo imaging in a setting where routine imaging is not performed. Secondly, the pattern, timing, and treatment of recurrent PDAC were assessed. This was a post hoc analysis of a prospective database of all consecutive patients undergoing pancreatic resection of PDAC between January 2011 and January 2015. Data on imaging procedures during follow-up, recurrence location, and treatment for recurrence were extracted and analyzed. Associations between clinical characteristics and post-recurrence survival were assessed with the log-rank test and Cox univariable and multivariable proportional hazards models. A total of 85 patients were included. Seventy-four patients (87%) underwent imaging procedures during follow-up at least once, with a mean amount of 3.1 ± 1.9 imaging procedures during the entire follow-up period. Sixty-eight patients (80%) were diagnosed with recurrence, 58 (85%) of whom after the manifestation of clinical symptoms. Additional tumor-specific treatment was administered in 17 of 68 patients (25%) with recurrence. Patients with isolated local recurrence, treatment after recurrence, and a recurrence-free survival >10 mo had longer post-recurrence survival. Even though a symptomatic follow-up strategy does not include routine imaging, the majority of patients with resected PDAC underwent additional imaging procedures during their follow-up period. Further prospective studies are needed to determine the actual clinical value, psychosocial implications, and cost-effectiveness of different forms of follow-up after resection of PDAC. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Tc-NGA imaging in liver transplantation: preliminary clinical experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodle, E.S.; Ward, R.E.; Stadalnik, R.C.

    1989-03-01

    Technetium-99m galactosyl-neoglycoalbumin (Tc-NGA) is a new liver imaging agent that binds to hepatic-binding protein, a hepatocyte-specific membrane receptor. The purpose of this study was to determine the potential of Tc-NGA imaging in clinical liver transplantation. A total of 25 studies were performed in nine patients. Imaging studies performed in the early posttransplant period in patients with good hepatic allograft function revealed diffuse patchiness in tracer distribution, a manifestation of preservation damage. Left lobar infarction was demonstrated within a few hours of ischemic injury. Right posterior segmental infarction was seen in another patient. Comparison of kinetic, clinical, and biochemical data revealedmore » good correlation between hepatic allograft function and Tc-NGA kinetics. Major kinetic alterations were noted during periods of preservation injury, hepatic infarction, and acute rejection. These studies indicate: (1) major alterations in Tc-NGA kinetics occur during preservation injury, hepatic infarction, and acute rejection, and (2) Tc-NGA kinetic data appear to provide an accurate reflection of hepatic allograft function. Tc-NGA imaging has the advantages of being noninvasive and of utilizing standard nuclear medicine instrumentation, including portable imaging devices. In conclusion, Tc-NGA imaging provides a promising noninvasive approach for evaluation of liver function in patients undergoing hepatic transplantation.« less

  3. A Review of Clinical and Imaging Findings in Eosinophilic Lung Diseases.

    PubMed

    Bernheim, Adam; McLoud, Theresa

    2017-05-01

    The purpose of this article is to review the clinical and imaging findings associated with eosinophilic lung diseases. The spectrum of eosinophilic lung diseases comprises a diverse group of pulmonary disorders that have an association with tissue or peripheral eosinophilia. These diseases have varied clinical presentations and may be associated with several other abnormalities. Characteristic imaging findings are often detected with chest radiography, and CT best shows parenchymal abnormalities. The integration of clinical, radiologic, and pathologic findings facilitates diagnosis and directs appropriate treatment.

  4. Performance Evaluation of an Automated ELISA System for Alzheimer's Disease Detection in Clinical Routine.

    PubMed

    Chiasserini, Davide; Biscetti, Leonardo; Farotti, Lucia; Eusebi, Paolo; Salvadori, Nicola; Lisetti, Viviana; Baschieri, Francesca; Chipi, Elena; Frattini, Giulia; Stoops, Erik; Vanderstichele, Hugo; Calabresi, Paolo; Parnetti, Lucilla

    2016-07-22

    The variability of Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers undermines their full-fledged introduction into routine diagnostics and clinical trials. Automation may help to increase precision and decrease operator errors, eventually improving the diagnostic performance. Here we evaluated three new CSF immunoassays, EUROIMMUNtrademark amyloid-β 1-40 (Aβ1-40), amyloid-β 1-42 (Aβ1-42), and total tau (t-tau), in combination with automated analysis of the samples. The CSF biomarkers were measured in a cohort consisting of AD patients (n = 28), mild cognitive impairment (MCI, n = 77), and neurological controls (OND, n = 35). MCI patients were evaluated yearly and cognitive functions were assessed by Mini-Mental State Examination. The patients clinically diagnosed with AD and MCI were classified according to the CSF biomarkers profile following NIA-AA criteria and the Erlangen score. Technical evaluation of the immunoassays was performed together with the calculation of their diagnostic performance. Furthermore, the results for EUROIMMUN Aβ1-42 and t-tau were compared to standard immunoassay methods (INNOTESTtrademark). EUROIMMUN assays for Aβ1-42 and t-tau correlated with INNOTEST (r = 0.83, p < 0.001 for both) and allowed a similar interpretation of the CSF profiles. The Aβ1-42/Aβ1-40 ratio measured with EUROIMMUN was the best parameter for AD detection and improved the diagnostic accuracy of Aβ1-42 (area under the curve = 0.93). In MCI patients, the Aβ1-42/Aβ1-40 ratio was associated with cognitive decline and clinical progression to AD.The diagnostic performance of the EUROIMMUN assays with automation is comparable to other currently used methods. The variability of the method and the value of the Aβ1-42/Aβ1-40 ratio in AD diagnosis need to be validated in large multi-center studies.

  5. Surveillance imaging for lymphoma: pros and cons.

    PubMed

    Lynch, Ryan C; Zelenetz, Andrew D; Armitage, James O; Carson, Kenneth R

    2014-01-01

    There is no international consensus on the optimal frequency or duration of computed tomography or positron emission tomography scanning for surveillance in patients who achieve complete remission after initial therapy for lymphoma. Although some clinical practice guidelines suggest periodic imaging is reasonable, others suggest little or no benefit to this practice. From a theoretical perspective, the frequency and duration of surveillance imaging is largely dependent upon the lymphoma subtype. Aggressive lymphomas with a fast growth rate will require surveillance more frequently and for a shorter duration compared to the indolent lymphomas. Historically, relapse has been detected in a majority of patients based upon clinically evident signs and symptoms. Currently, no study has demonstrated an overall survival difference for patients with relapse detected by imaging as opposed to clinical evaluation, although one study did demonstrate a lower second-line International Prognostic Index in patients with relapse detected by surveillance imaging. Enthusiasm for this finding has been tempered by recent studies highlighting the potential long-term risk of secondary malignancies because of ionizing radiation exposure from diagnostic imaging. These factors along with the significant costs associated with diagnostic imaging have contributed to an ongoing debate regarding the relative costs, risks, and benefits of radiographic surveillance. Herein we present perspectives for and against routine surveillance imaging in an effort to facilitate a better understanding of the issues relevant to what is ultimately a clinical decision made by an oncologist and his or her patient.

  6. Quantitative Metrics in Clinical Radiology Reporting: A Snapshot Perspective from a Single Mixed Academic-Community Practice

    PubMed Central

    Abramson, Richard G.; Su, Pei-Fang; Shyr, Yu

    2012-01-01

    Quantitative imaging has emerged as a leading priority on the imaging research agenda, yet clinical radiology has traditionally maintained a skeptical attitude toward numerical measurement in diagnostic interpretation. To gauge the extent to which quantitative reporting has been incorporated into routine clinical radiology practice, and to offer preliminary baseline data against which the evolution of quantitative imaging can be measured, we obtained all clinical computed tomography (CT) and magnetic resonance imaging (MRI) reports from two randomly selected weekdays in 2011 at a single mixed academic-community practice and evaluated those reports for the presence of quantitative descriptors. We found that 44% of all reports contained at least one “quantitative metric” (QM), defined as any numerical descriptor of a physical property other than quantity, but only 2% of reports contained an “advanced quantitative metric” (AQM), defined as a numerical parameter reporting on lesion function or composition, excluding simple size and distance measurements. Possible reasons for the slow translation of AQMs into routine clinical radiology reporting include perceptions that the primary clinical question may be qualitative in nature or that a qualitative answer may be sufficient; concern that quantitative approaches may obscure important qualitative information, may not be adequately validated, or may not allow sufficient expression of uncertainty; the feeling that “gestalt” interpretation may be superior to quantitative paradigms; and practical workflow limitations. We suggest that quantitative imaging techniques will evolve primarily as dedicated instruments for answering specific clinical questions requiring precise and standardized interpretation. Validation in real-world settings, ease of use, and reimbursement economics will all play a role in determining the rate of translation of AQMs into broad practice. PMID:22795791

  7. A clinical evaluation of placental growth factor in routine practice in high-risk women presenting with suspected pre-eclampsia and/or fetal growth restriction.

    PubMed

    Ormesher, L; Johnstone, E D; Shawkat, E; Dempsey, A; Chmiel, C; Ingram, E; Higgins, L E; Myers, J E

    2018-03-13

    To evaluate the use of plasma Placental Growth Factor (PlGF), recommended by the recent NICE guidance, in women with suspected pre-eclampsia (PE) and/or fetal growth restriction (FGR). Non-randomised prospective clinical evaluation study in high-risk antenatal clinics in a tertiary maternity unit. PlGF testing was performed in addition to routine clinical assessment in 260 women >20 weeks' gestation with chronic disease (hypertension, renal disease ± diabetes) with a change in maternal condition or in women with suspected FGR to determine the impact on clinical management. Results were revealed and standardised care pathways followed. Outcome of pregnancies with a low PlGF (<12 pg/ml and 13-100 pg/ml), impact on clinical service and the diagnostic accuracy of alternative PlGF cut-offs. 206/260 (79.2%) women had an adverse outcome (PE/birthweight < 10th centile/preterm birth). In our cohort, a low PlGF (<12 pg/ml) was associated with a shorter test-birth interval and universally (100% PPV) with an adverse pregnancy outcome, although 29/61 (47.5%) of women with PlGF < 12 pg/ml continued their pregnancy >14 days. The PlGF result altered clinical management (surveillance or timing of birth) in 196/260 (75.4%) cases. Alternative PlGF thresholds did not significantly improve diagnostic performance. Our evaluation confirms the value of PlGF as a diagnostic tool for placental dysfunction. However, low PlGF in isolation should not trigger iatrogenic delivery. Further research linking placental pathology, maternal disease and maternal PlGF levels is urgently needed before this test can be implemented in routine clinical practice. Copyright © 2018. Published by Elsevier B.V.

  8. An adaptive optics imaging system designed for clinical use.

    PubMed

    Zhang, Jie; Yang, Qiang; Saito, Kenichi; Nozato, Koji; Williams, David R; Rossi, Ethan A

    2015-06-01

    Here we demonstrate a new imaging system that addresses several major problems limiting the clinical utility of conventional adaptive optics scanning light ophthalmoscopy (AOSLO), including its small field of view (FOV), reliance on patient fixation for targeting imaging, and substantial post-processing time. We previously showed an efficient image based eye tracking method for real-time optical stabilization and image registration in AOSLO. However, in patients with poor fixation, eye motion causes the FOV to drift substantially, causing this approach to fail. We solve that problem here by tracking eye motion at multiple spatial scales simultaneously by optically and electronically integrating a wide FOV SLO (WFSLO) with an AOSLO. This multi-scale approach, implemented with fast tip/tilt mirrors, has a large stabilization range of ± 5.6°. Our method consists of three stages implemented in parallel: 1) coarse optical stabilization driven by a WFSLO image, 2) fine optical stabilization driven by an AOSLO image, and 3) sub-pixel digital registration of the AOSLO image. We evaluated system performance in normal eyes and diseased eyes with poor fixation. Residual image motion with incremental compensation after each stage was: 1) ~2-3 arc minutes, (arcmin) 2) ~0.5-0.8 arcmin and, 3) ~0.05-0.07 arcmin, for normal eyes. Performance in eyes with poor fixation was: 1) ~3-5 arcmin, 2) ~0.7-1.1 arcmin and 3) ~0.07-0.14 arcmin. We demonstrate that this system is capable of reducing image motion by a factor of ~400, on average. This new optical design provides additional benefits for clinical imaging, including a steering subsystem for AOSLO that can be guided by the WFSLO to target specific regions of interest such as retinal pathology and real-time averaging of registered images to eliminate image post-processing.

  9. An adaptive optics imaging system designed for clinical use

    PubMed Central

    Zhang, Jie; Yang, Qiang; Saito, Kenichi; Nozato, Koji; Williams, David R.; Rossi, Ethan A.

    2015-01-01

    Here we demonstrate a new imaging system that addresses several major problems limiting the clinical utility of conventional adaptive optics scanning light ophthalmoscopy (AOSLO), including its small field of view (FOV), reliance on patient fixation for targeting imaging, and substantial post-processing time. We previously showed an efficient image based eye tracking method for real-time optical stabilization and image registration in AOSLO. However, in patients with poor fixation, eye motion causes the FOV to drift substantially, causing this approach to fail. We solve that problem here by tracking eye motion at multiple spatial scales simultaneously by optically and electronically integrating a wide FOV SLO (WFSLO) with an AOSLO. This multi-scale approach, implemented with fast tip/tilt mirrors, has a large stabilization range of ± 5.6°. Our method consists of three stages implemented in parallel: 1) coarse optical stabilization driven by a WFSLO image, 2) fine optical stabilization driven by an AOSLO image, and 3) sub-pixel digital registration of the AOSLO image. We evaluated system performance in normal eyes and diseased eyes with poor fixation. Residual image motion with incremental compensation after each stage was: 1) ~2–3 arc minutes, (arcmin) 2) ~0.5–0.8 arcmin and, 3) ~0.05–0.07 arcmin, for normal eyes. Performance in eyes with poor fixation was: 1) ~3–5 arcmin, 2) ~0.7–1.1 arcmin and 3) ~0.07–0.14 arcmin. We demonstrate that this system is capable of reducing image motion by a factor of ~400, on average. This new optical design provides additional benefits for clinical imaging, including a steering subsystem for AOSLO that can be guided by the WFSLO to target specific regions of interest such as retinal pathology and real-time averaging of registered images to eliminate image post-processing. PMID:26114033

  10. The incremental impact of cardiac MRI on clinical decision-making.

    PubMed

    Rajwani, Adil; Stewart, Michael J; Richardson, James D; Child, Nicholas M; Maredia, Neil

    2016-01-01

    Despite a significant expansion in the use of cardiac MRI (CMR), there is inadequate evaluation of its incremental impact on clinical decision-making over and above other well-established modalities. We sought to determine the incremental utility of CMR in routine practice. 629 consecutive CMR studies referred by 44 clinicians from 9 institutions were evaluated. Pre-defined algorithms were used to determine the incremental influence on diagnostic thinking, influence on clinical management and thus the overall clinical utility. Studies were also subdivided and evaluated according to the indication for CMR. CMR provided incremental information to the clinician in 85% of cases, with incremental influence on diagnostic thinking in 85% of cases and incremental impact on management in 42% of cases. The overall incremental utility of CMR exceeded 90% in 7 out of the 13 indications, whereas in settings such as the evaluation of unexplained ventricular arrhythmia or mild left ventricular systolic dysfunction, this was <50%. CMR was frequently able to inform and influence decision-making in routine clinical practice, even with analyses that accepted only incremental clinical information and excluded a redundant duplication of imaging. Significant variations in yield were noted according to the indication for CMR. These data support a wider integration of CMR services into cardiac imaging departments. These data are the first to objectively evaluate the incremental value of a UK CMR service in clinical decision-making. Such data are essential when seeking justification for a CMR service.

  11. Adaptive optics imaging of geographic atrophy.

    PubMed

    Gocho, Kiyoko; Sarda, Valérie; Falah, Sabrina; Sahel, José-Alain; Sennlaub, Florian; Benchaboune, Mustapha; Ullern, Martine; Paques, Michel

    2013-05-01

    To report the findings of en face adaptive optics (AO) near infrared (NIR) reflectance fundus flood imaging in eyes with geographic atrophy (GA). Observational clinical study of AO NIR fundus imaging was performed in 12 eyes of nine patients with GA, and in seven controls using a flood illumination camera operating at 840 nm, in addition to routine clinical examination. To document short term and midterm changes, AO imaging sessions were repeated in four patients (mean interval between sessions 21 days; median follow up 6 months). As compared with scanning laser ophthalmoscope imaging, AO NIR imaging improved the resolution of the changes affecting the RPE. Multiple hyporeflective clumps were seen within and around GA areas. Time-lapse imaging revealed micrometric-scale details of the emergence and progression of areas of atrophy as well as the complex kinetics of some hyporeflective clumps. Such dynamic changes were observed within as well as outside atrophic areas. in eyes affected by GA, AO nir imaging allows high resolution documentation of the extent of RPE damage. this also revealed that a complex, dynamic process of redistribution of hyporeflective clumps throughout the posterior pole precedes and accompanies the emergence and progression of atrophy. therefore, these clumps are probably also a biomarker of rpe damage. AO NIR imaging may, therefore, be of interest to detect the earliest stages, to document the retinal pathology and to monitor the progression oF GA. (ClinicalTrials.gov number, NCT01546181.).

  12. Imaging intratumor heterogeneity: role in therapy response, resistance, and clinical outcome.

    PubMed

    O'Connor, James P B; Rose, Chris J; Waterton, John C; Carano, Richard A D; Parker, Geoff J M; Jackson, Alan

    2015-01-15

    Tumors exhibit genomic and phenotypic heterogeneity, which has prognostic significance and may influence response to therapy. Imaging can quantify the spatial variation in architecture and function of individual tumors through quantifying basic biophysical parameters such as CT density or MRI signal relaxation rate; through measurements of blood flow, hypoxia, metabolism, cell death, and other phenotypic features; and through mapping the spatial distribution of biochemical pathways and cell signaling networks using PET, MRI, and other emerging molecular imaging techniques. These methods can establish whether one tumor is more or less heterogeneous than another and can identify subregions with differing biology. In this article, we review the image analysis methods currently used to quantify spatial heterogeneity within tumors. We discuss how analysis of intratumor heterogeneity can provide benefit over more simple biomarkers such as tumor size and average function. We consider how imaging methods can be integrated with genomic and pathology data, instead of being developed in isolation. Finally, we identify the challenges that must be overcome before measurements of intratumoral heterogeneity can be used routinely to guide patient care. ©2014 American Association for Cancer Research.

  13. Lung magnetic resonance imaging for pneumonia in children.

    PubMed

    Liszewski, Mark C; Görkem, Süreyya; Sodhi, Kushaljit S; Lee, Edward Y

    2017-10-01

    Technical factors have historically limited the role of MRI in the evaluation of pneumonia in children in routine clinical practice. As imaging technology has advanced, recent studies utilizing practical MR imaging protocols have shown MRI to be an accurate potential alternative to CT for the evaluation of pneumonia and its complications. This article provides up-to-date MR imaging techniques that can be implemented in most radiology departments to evaluate pneumonia in children. Imaging findings in pneumonia on MRI are also reviewed. In addition, the current literature describing the diagnostic performance of MRI for pneumonia is discussed. Furthermore, potential risks and limitations of MRI for the evaluation of pneumonia in children are described.

  14. Optical Imaging of Ionizing Radiation from Clinical Sources.

    PubMed

    Shaffer, Travis M; Drain, Charles Michael; Grimm, Jan

    2016-11-01

    Nuclear medicine uses ionizing radiation for both in vivo diagnosis and therapy. Ionizing radiation comes from a variety of sources, including x-rays, beam therapy, brachytherapy, and various injected radionuclides. Although PET and SPECT remain clinical mainstays, optical readouts of ionizing radiation offer numerous benefits and complement these standard techniques. Furthermore, for ionizing radiation sources that cannot be imaged using these standard techniques, optical imaging offers a unique imaging alternative. This article reviews optical imaging of both radionuclide- and beam-based ionizing radiation from high-energy photons and charged particles through mechanisms including radioluminescence, Cerenkov luminescence, and scintillation. Therapeutically, these visible photons have been combined with photodynamic therapeutic agents preclinically for increasing therapeutic response at depths difficult to reach with external light sources. Last, new microscopy methods that allow single-cell optical imaging of radionuclides are reviewed. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  15. Modern nuclear cardiac imaging in diagnosis and clinical management of patients with left ventricular dysfunction.

    PubMed

    Abidov, A; Hachamovitch, R; Berman, D S

    2004-12-01

    Congestive heart failure (CHF) has become a large social burden in modern Western society, with very high morbidity and mortality and extremely large financial costs. The largest cause of CHF is coronary heart disease, with ventricular dysfunction that may or may not be reversible by revascularization. Thus, evaluation of the viable myocardial tissue in patients with ischemic left ventricular (LV) dysfunction has important clinical and therapeutic implications. Furthermore, since patients with ventricular dysfunction are at higher operative risk, cardiologists and cardiac surgeons are commonly faced with issues regarding the balance between the potential risk vs benefit of revascularization procedures. Cardiac nuclear imaging [myocardial perfusion SPECT (MPS) and positron emission tomography (PET)] provide objective information that augments standard clinical and angiographic assessments of patients with ventricular dysfunction with respect to diagnosis (etiology), prognosis, and potential benefit from intervention. Development of the technology and methodology of gated MPS, now the routine method for MPS, allows assessment of the extent and severity of inducible ischemia as well as hypoperfused but viable myocardium, and also provides measurements of LV ejection fraction, regional wall motion, LV volume measurements, diastolic function and LV geometry. With PET, myocardial metabolism and blood flow reserve can be added to the measurements provided by nuclear cardiology procedures. This paper provides insight into the current evidence regarding settings in which nuclear cardiac imaging procedures are helpful in assessment of patients in the setting of coronary artery disease with severe LV dysfunction. A risk-benefit approach to MPS results is proposed, with principal focus on identifying patients at risk for major cardiac events who may benefit from myocardial revascularization.

  16. A Picture is Worth 1,000 Words. The Use of Clinical Images in Electronic Medical Records.

    PubMed

    Ai, Angela C; Maloney, Francine L; Hickman, Thu-Trang; Wilcox, Allison R; Ramelson, Harley; Wright, Adam

    2017-07-12

    To understand how clinicians utilize image uploading tools in a home grown electronic health records (EHR) system. A content analysis of patient notes containing non-radiological images from the EHR was conducted. Images from 4,000 random notes from July 1, 2009 - June 30, 2010 were reviewed and manually coded. Codes were assigned to four properties of the image: (1) image type, (2) role of image uploader (e.g. MD, NP, PA, RN), (3) practice type (e.g. internal medicine, dermatology, ophthalmology), and (4) image subject. 3,815 images from image-containing notes stored in the EHR were reviewed and manually coded. Of those images, 32.8% were clinical and 66.2% were non-clinical. The most common types of the clinical images were photographs (38.0%), diagrams (19.1%), and scanned documents (14.4%). MDs uploaded 67.9% of clinical images, followed by RNs with 10.2%, and genetic counselors with 6.8%. Dermatology (34.9%), ophthalmology (16.1%), and general surgery (10.8%) uploaded the most clinical images. The content of clinical images referencing body parts varied, with 49.8% of those images focusing on the head and neck region, 15.3% focusing on the thorax, and 13.8% focusing on the lower extremities. The diversity of image types, content, and uploaders within a home grown EHR system reflected the versatility and importance of the image uploading tool. Understanding how users utilize image uploading tools in a clinical setting highlights important considerations for designing better EHR tools and the importance of interoperability between EHR systems and other health technology.

  17. The use and impact of cancer medicines in routine clinical care: methods and observations in a cohort of elderly Australians

    PubMed Central

    Pearson, Sallie-Anne; Schaffer, Andrea

    2014-01-01

    Introduction After medicines have been subsidised in Australia we know little about their use in routine clinical practice, impact on resource utilisation, effectiveness or safety. Routinely collected administrative health data are available to address these issues in large population-based pharmacoepidemiological studies. By bringing together cross-jurisdictional data collections that link drug exposure to real-world outcomes, this research programme aims to evaluate the use and impact of cancer medicines in a subset of elderly Australians in the real-world clinical setting. Methods and analysis This ongoing research programme involves a series of retrospective cohort studies of Australian Government Department of Veterans’ Affairs (DVA) clients. The study population includes 104 635 veterans who reside in New South Wales, Australia, and were aged 65 years and over as of 1 July 2004. We will investigate trends in cancer medicines use according to cancer type and other sociodemographic characteristics as well as predictors of the initiation of cancer medicines and other treatment modalities, survival and adverse outcomes among patients with cancer. The programme is underpinned by the linkage of eight health administrative databases under the custodianship of the DVA and the New South Wales Ministry of Health, including cancer notifications, medicines dispensing data, hospitalisation data and health services data. The cancer notifications database is available from 1994 with all other databases available from 2005 onwards. Ethics and dissemination Ethics approval has been granted by the DVA and New South Wales Population and Health Service Research Ethics Committees. Results Results will be reported in peer-reviewed publications, conference presentations and policy forums. The programme has high translational potential, providing invaluable evidence about cancer medicines in an elderly population who are under-represented in clinical trials. PMID:24793244

  18. Magnetic resonance microscopy of prostate tissue: How basic science can inform clinical imaging development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bourne, Roger

    2013-03-15

    This commentary outlines how magnetic resonance imaging (MRI) microscopy studies of prostate tissue samples and whole organs have shed light on a number of clinical imaging mysteries and may enable more effective development of new clinical imaging methods.

  19. Design of an image-distribution service from a clinical PACS

    NASA Astrophysics Data System (ADS)

    Gehring, Dale G.; Persons, Kenneth R.; Rothman, Melvyn L.; Felmlee, Joel P.; Gerhart, D. J.; Hangiandreou, Nicholas J.; Reardon, Frank J.; Shirk, M.; Forbes, Glenn S.; Williamson, Byrn, Jr.

    1994-05-01

    A PACS system has been developed through a multi-phase collaboration between the Mayo Clinic and IBM/Rochester. The current system has been fully integrated into the clinical practice of the Radiology Department for the primary purpose of digital image archival, retrieval, and networked workstation review. Work currently in progress includes the design and implementation of a gateway device for providing digital image data to third-party workstations, laser printers, and other devices, for users both within and outside of the Radiology Department.

  20. Psychometric characteristics of Clinical Reasoning Problems (CRPs) and its correlation with routine multiple choice question (MCQ) in Cardiology department

    PubMed Central

    DERAKHSHANDEH, ZAHRA; AMINI, MITRA; KOJURI, JAVAD; DEHBOZORGIAN, MARZIYEH

    2018-01-01

    Introduction: Clinical reasoning is one of the most important skills in the process of training a medical student to become an efficient physician. Assessment of the reasoning skills in a medical school program is important to direct students’ learning. One of the tests for measuring the clinical reasoning ability is Clinical Reasoning Problems (CRPs). The major aim of this study is to measure psychometric qualities of CRPs and define correlation between this test and routine MCQ in cardiology department of Shiraz medical school. Methods: This study was a descriptive study conducted on total cardiology residents of Shiraz Medical School. The study population consists of 40 residents in 2014. The routine CRPs and the MCQ tests was designed based on similar objectives and were carried out simultaneously. Reliability, item difficulty, item discrimination, and correlation between each item and the total score of CRPs were all measured by Excel and SPSS software for checking psycometeric CRPs test. Furthermore, we calculated the correlation between CRPs test and MCQ test. The mean differences of CRPs test score between residents’ academic year [second, third and fourth year] were also evaluated by Analysis of variances test (One Way ANOVA) using SPSS software (version 20)(α=0.05). Results: The mean and standard deviation of score in CRPs was 10.19 ±3.39 out of 20; in MCQ, it was 13.15±3.81 out of 20. Item difficulty was in the range of 0.27-0.72; item discrimination was 0.30-0.75 with question No.3 being the exception (that was 0.24). The correlation between each item and the total score of CRP was 0.26-0.87; the correlation between CRPs test and MCQ test was 0.68 (p<0.001). The reliability of the CRPs was 0.72 as calculated by using Cronbach's alpha. The mean score of CRPs was different among residents based on their academic year and this difference was statistically significant (p<0.001). Conclusion: The results of this present investigation revealed that CRPs

  1. Psychometric characteristics of Clinical Reasoning Problems (CRPs) and its correlation with routine multiple choice question (MCQ) in Cardiology department.

    PubMed

    Derakhshandeh, Zahra; Amini, Mitra; Kojuri, Javad; Dehbozorgian, Marziyeh

    2018-01-01

    Clinical reasoning is one of the most important skills in the process of training a medical student to become an efficient physician. Assessment of the reasoning skills in a medical school program is important to direct students' learning. One of the tests for measuring the clinical reasoning ability is Clinical Reasoning Problems (CRPs). The major aim of this study is to measure psychometric qualities of CRPs and define correlation between this test and routine MCQ in cardiology department of Shiraz medical school. This study was a descriptive study conducted on total cardiology residents of Shiraz Medical School. The study population consists of 40 residents in 2014. The routine CRPs and the MCQ tests was designed based on similar objectives and were carried out simultaneously. Reliability, item difficulty, item discrimination, and correlation between each item and the total score of CRPs were all measured by Excel and SPSS software for checking psycometeric CRPs test. Furthermore, we calculated the correlation between CRPs test and MCQ test. The mean differences of CRPs test score between residents' academic year [second, third and fourth year] were also evaluated by Analysis of variances test (One Way ANOVA) using SPSS software (version 20)(α=0.05). The mean and standard deviation of score in CRPs was 10.19 ±3.39 out of 20; in MCQ, it was 13.15±3.81 out of 20. Item difficulty was in the range of 0.27-0.72; item discrimination was 0.30-0.75 with question No.3 being the exception (that was 0.24). The correlation between each item and the total score of CRP was 0.26-0.87; the correlation between CRPs test and MCQ test was 0.68 (p<0.001). The reliability of the CRPs was 0.72 as calculated by using Cronbach's alpha. The mean score of CRPs was different among residents based on their academic year and this difference was statistically significant (p<0.001). The results of this present investigation revealed that CRPs could be reliable test for measuring clinical

  2. Role of routine abdominal ultrasonography in intensified tuberculosis case finding algorithms at HIV clinics in high TB burden settings.

    PubMed

    Spalgais, Sonam; Agarwal, Upasna; Sarin, Rohit; Chauhan, Devesh; Yadav, Anita; Jaiswal, Anand

    2017-05-18

    High proportion of TB in people living with HIV (PLHIV) is undiagnosed. Due to this active TB case finding is recommended for HIV clinics in high TB burden countries. Presently sputum examination and chest radiography are frontline tests recommended for HIV infected TB presumptives. Abdominal TB which occurs frequently in PLHIV may be missed even by existing programmatic intensified case finding protocols. This study evaluated the routine use of ultrasonography (USG) for active case finding of abdominal TB in HIV clinics. Retrospective analysis of eight years' data from an HIV Clinic in a TB hospital in India. Patients underwent chest x-ray, sputum examination, USG abdomen and routine blood tests at entry to HIV care. Case forms were scrutinized for diagnosis of TB, USG findings and CD4 cell counts. Abdominal TB was classified as probable or possible TB. Probable TB was based on presence of two major USG (abdomen) findings suggestive of active TB, or one major USG finding with at least two minor USG findings or at least two symptoms, or any USG finding with microbiologically confirmed active TB at another site. Possible TB was based on the presence of one major USG finding, or the presence of two minor USG findings with at least two symptoms. Bacteriological confirmation was not obtained. Eight hundred and eighty-nine people PLHIV underwent a baseline USG abdomen. One hundred and thirteen of 340 cases already diagnosed with TB and 87 of the 91 newly diagnosed with TB at time of HIV clinic registration had abdominal TB. Non-abdominal symptoms like weight loss, fever and cough were seen in 53% and 22% cases had no symptoms at all. Enlarged abdominal lymph nodes with central caseation, ascitis, splenic microabsesses, bowel thickening and hepatosplenomegaly were the USG findings in these cases. Abdominal TB is a frequent TB site in PLHIV presenting with non-abdominal symptoms. It can be easily detected on basis of features seen on a simple abdominal ultrasound

  3. Technetium-99m NGA functional hepatic imaging: preliminary clinical experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Vera, D.R.; Woodle, E.S.

    1985-11-01

    Technetium-99m galactosyl-neoglycoalbumin ( (Tc)NGA) is a radiolabeled ligand to hepatic binding protein, a receptor which resides at the plasma membrane of hepatocytes. This receptor-binding radiopharmaceutical and its kinetic model provide a noninvasive method for the assessment of liver function. Eighteen patients were studied: seven with hepatoma, eight with liver metastases, four with cirrhosis, and one patient with acute fulminant non-A, non-B hepatitis. Technetium-99m NGA liver imaging provided anatomic information of diagnostic quality comparable to that obtained with other routine imaging modalities, including computed tomography, angiography, ultrasound, and (Tc)sulfur colloid scintigraphy. Kinetic modeling of dynamic (Tc)NGA data produced estimates of standardizedmore » hepatic blood flow, Q (hepatic blood flow divided by total blood volume), and hepatic binding protein concentration, (HBP). Significant rank correlation was obtained between (HBP) estimates and CTC scores. This correlation supports the hypothesis that (HBP) is a measure of functional hepatocyte mass. The combination of decreased Q and markedly reduced (HBP) may have prognostic significance; all three patients with this combination died of hepatic failure within 6 wk of imaging.« less

  4. Clinical evaluation of reducing acquisition time on single-photon emission computed tomography image quality using proprietary resolution recovery software.

    PubMed

    Aldridge, Matthew D; Waddington, Wendy W; Dickson, John C; Prakash, Vineet; Ell, Peter J; Bomanji, Jamshed B

    2013-11-01

    A three-dimensional model-based resolution recovery (RR) reconstruction algorithm that compensates for collimator-detector response, resulting in an improvement in reconstructed spatial resolution and signal-to-noise ratio of single-photon emission computed tomography (SPECT) images, was tested. The software is said to retain image quality even with reduced acquisition time. Clinically, any improvement in patient throughput without loss of quality is to be welcomed. Furthermore, future restrictions in radiotracer supplies may add value to this type of data analysis. The aims of this study were to assess improvement in image quality using the software and to evaluate the potential of performing reduced time acquisitions for bone and parathyroid SPECT applications. Data acquisition was performed using the local standard SPECT/CT protocols for 99mTc-hydroxymethylene diphosphonate bone and 99mTc-methoxyisobutylisonitrile parathyroid SPECT imaging. The principal modification applied was the acquisition of an eight-frame gated data set acquired using an ECG simulator with a fixed signal as the trigger. This had the effect of partitioning the data such that the effect of reduced time acquisitions could be assessed without conferring additional scanning time on the patient. The set of summed data sets was then independently reconstructed using the RR software to permit a blinded assessment of the effect of acquired counts upon reconstructed image quality as adjudged by three experienced observers. Data sets reconstructed with the RR software were compared with the local standard processing protocols; filtered back-projection and ordered-subset expectation-maximization. Thirty SPECT studies were assessed (20 bone and 10 parathyroid). The images reconstructed with the RR algorithm showed improved image quality for both full-time and half-time acquisitions over local current processing protocols (P<0.05). The RR algorithm improved image quality compared with local processing

  5. The frequency and severity of capecitabine-induced hypertriglyceridaemia in routine clinical practice: a prospective study

    PubMed Central

    Michie, C O; Sakala, M; Rivans, I; Strachan, M W J; Clive, S

    2010-01-01

    Background: Capecitabine is known to rarely cause raised serum triglycerides (TG). In our centre, several patients receiving capecitabine developed raised TG levels corresponding to the ‘very high risk' category for potentially serious acute pancreatitis. Methods: A fasting blood lipid screening protocol was introduced into clinical practice for patients receiving capecitabine. Patients with TGs >5 mmol l−1 were treated and followed up. An 18-month prospective audit was performed to establish the incidence and severity of capecitabine-induced hypertriglyceridaemia (CIHT). Results: A total of 304 patients received capecitabine for colorectal cancer between January 2008 and June 2009. Of these, 212 patients (70%) were screened and 8 (3.7%) developed clinically significant hypertriglyceridaemia requiring lipid-lowering therapy. Two of the eight patients had diabetes and one had pre-existing dyslipidaemia. One suffered cerebral infarction during chemotherapy. There were no cases of acute pancreatitis. Follow-up showed that serum TGs safely and rapidly returned to normal with appropriate treatment without discontinuation of capecitabine. Conclusions: This is the first prospective study evaluating CIHT. These results suggest that it should be classed as a ‘common' undesired effect of capecitabine. Despite this, the incidence does not justify routine screening in all patients. Targeted screening in those with diabetes or pre-existing hyperlipidaemia is recommended, together with adoption of a clear management policy. PMID:20664584

  6. Medical image segmentation using 3D MRI data

    NASA Astrophysics Data System (ADS)

    Voronin, V.; Marchuk, V.; Semenishchev, E.; Cen, Yigang; Agaian, S.

    2017-05-01

    Precise segmentation of three-dimensional (3D) magnetic resonance imaging (MRI) image can be a very useful computer aided diagnosis (CAD) tool in clinical routines. Accurate automatic extraction a 3D component from images obtained by magnetic resonance imaging (MRI) is a challenging segmentation problem due to the small size objects of interest (e.g., blood vessels, bones) in each 2D MRA slice and complex surrounding anatomical structures. Our objective is to develop a specific segmentation scheme for accurately extracting parts of bones from MRI images. In this paper, we use a segmentation algorithm to extract the parts of bones from Magnetic Resonance Imaging (MRI) data sets based on modified active contour method. As a result, the proposed method demonstrates good accuracy in a comparison between the existing segmentation approaches on real MRI data.

  7. Prototypes for Content-Based Image Retrieval in Clinical Practice

    PubMed Central

    Depeursinge, Adrien; Fischer, Benedikt; Müller, Henning; Deserno, Thomas M

    2011-01-01

    Content-based image retrieval (CBIR) has been proposed as key technology for computer-aided diagnostics (CAD). This paper reviews the state of the art and future challenges in CBIR for CAD applied to clinical practice. We define applicability to clinical practice by having recently demonstrated the CBIR system on one of the CAD demonstration workshops held at international conferences, such as SPIE Medical Imaging, CARS, SIIM, RSNA, and IEEE ISBI. From 2009 to 2011, the programs of CADdemo@CARS and the CAD Demonstration Workshop at SPIE Medical Imaging were sought for the key word “retrieval” in the title. The systems identified were analyzed and compared according to the hierarchy of gaps for CBIR systems. In total, 70 software demonstrations were analyzed. 5 systems were identified meeting the criterions. The fields of application are (i) bone age assessment, (ii) bone fractures, (iii) interstitial lung diseases, and (iv) mammography. Bridging the particular gaps of semantics, feature extraction, feature structure, and evaluation have been addressed most frequently. In specific application domains, CBIR technology is available for clinical practice. While system development has mainly focused on bridging content and feature gaps, performance and usability have become increasingly important. The evaluation must be based on a larger set of reference data, and workflow integration must be achieved before CBIR-CAD is really established in clinical practice. PMID:21892374

  8. Clinical routine utility of basophil activation testing for diagnosis of hymenoptera-allergic patients with emphasis on individuals with negative venom-specific IgE antibodies.

    PubMed

    Korošec, Peter; Šilar, Mira; Eržen, Renato; Čelesnik, Nina; Bajrović, Nissera; Zidarn, Mihaela; Košnik, Mitja

    2013-01-01

    Previous reports suggest the usefulness of basophil activation testing (BAT) in Hymenoptera-allergic patients with negative venom-specific IgE antibodies. We sought to evaluate the diagnostic utility of this testing in a routine clinical laboratory setting. Twenty-one patients with anaphylactic reactions to Hymenoptera sting (median grade III) and negative venom-specific IgE were routinely and prospectively tested with BAT. We were able to diagnose 81% (17 of 21) of patients with BAT and 57% (12 of 21) with intradermal skin testing. Three wasp venom-allergic patients showed IgE positivity to rVes v 5. Four patients (19%) were negative for all tests. In the case of double-positive BAT, the culprit insect correlated with the venom that induced a significantly higher basophil response. BAT allows the identification of severe Hymenoptera-allergic patients with negative specific IgE and skin tests. The routine use of this cellular test should facilitate prescription of venom immunotherapy in complex cases with inconclusive diagnostic results. Copyright © 2013 S. Karger AG, Basel.

  9. Enhancements in hepatobiliary imaging: the spectrum of gadolinium-ethoxybenzyl diethylenetriaminepentaacetic acid usages in hepatobiliary magnetic resonance imaging.

    PubMed

    Channual, Stephanie; Pahwa, Anokh; Lu, David S; Raman, Steven S

    2016-09-01

    Gadolinium-ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) is a unique hepatocyte-specific contrast agent approved for clinical use in the United States in 2008. Gd-EOB-DTPA-enhanced MR has shown to improve detection and characterization of hepatic lesions. Gd-EOB-DTPA is now being routinely used in daily clinical practice worldwide. Therefore, it is important for radiologists to be familiar with the potential uses and pitfalls of Gd-EOB-DTPA, which extends beyond the assessment of focal hepatic lesions. The purpose of this article is to review the various usages of Gd-EOB-DTPA in hepatobiliary MR imaging.

  10. Optical Imaging of Ionizing Radiation from Clinical Sources

    PubMed Central

    Shaffer, Travis M.; Drain, Charles Michael

    2016-01-01

    Nuclear medicine uses ionizing radiation for both in vivo diagnosis and therapy. Ionizing radiation comes from a variety of sources, including x-rays, beam therapy, brachytherapy, and various injected radionuclides. Although PET and SPECT remain clinical mainstays, optical readouts of ionizing radiation offer numerous benefits and complement these standard techniques. Furthermore, for ionizing radiation sources that cannot be imaged using these standard techniques, optical imaging offers a unique imaging alternative. This article reviews optical imaging of both radionuclide- and beam-based ionizing radiation from high-energy photons and charged particles through mechanisms including radioluminescence, Cerenkov luminescence, and scintillation. Therapeutically, these visible photons have been combined with photodynamic therapeutic agents preclinically for increasing therapeutic response at depths difficult to reach with external light sources. Last, new microscopy methods that allow single-cell optical imaging of radionuclides are reviewed. PMID:27688469

  11. Clinical introduction of image lag correction for a cone beam CT system.

    PubMed

    Stankovic, Uros; Ploeger, Lennert S; Sonke, Jan-Jakob; van Herk, Marcel

    2016-03-01

    Image lag in the flat-panel detector used for Linac integrated cone beam computed tomography (CBCT) has a degrading effect on CBCT image quality. The most prominent visible artifact is the presence of bright semicircular structure in the transverse view of the scans, known also as radar artifact. Several correction strategies have been proposed, but until now the clinical introduction of such corrections remains unreported. In November 2013, the authors have clinically implemented a previously proposed image lag correction on all of their machines at their main site in Amsterdam. The purpose of this study was to retrospectively evaluate the effect of the correction on the quality of CBCT images and evaluate the required calibration frequency. Image lag was measured in five clinical CBCT systems (Elekta Synergy 4.6) using an in-house developed beam interrupting device that stops the x-ray beam midway through the data acquisition of an unattenuated beam for calibration. A triple exponential falling edge response was fitted to the measured data and used to correct image lag from projection images with an infinite response. This filter, including an extrapolation for saturated pixels, was incorporated in the authors' in-house developed clinical cbct reconstruction software. To investigate the short-term stability of the lag and associated parameters, a series of five image lag measurement over a period of three months was performed. For quantitative analysis, the authors have retrospectively selected ten patients treated in the pelvic region. The apparent contrast was quantified in polar coordinates for scans reconstructed using the parameters obtained from different dates with and without saturation handling. Visually, the radar artifact was minimal in scans reconstructed using image lag correction especially when saturation handling was used. In patient imaging, there was a significant reduction of the apparent contrast from 43 ± 16.7 to 15.5 ± 11.9 HU without the

  12. Clinical introduction of image lag correction for a cone beam CT system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stankovic, Uros; Ploeger, Lennert S.; Sonke, Jan-Jakob, E-mail: j.sonke@nki.nl

    Purpose: Image lag in the flat-panel detector used for Linac integrated cone beam computed tomography (CBCT) has a degrading effect on CBCT image quality. The most prominent visible artifact is the presence of bright semicircular structure in the transverse view of the scans, known also as radar artifact. Several correction strategies have been proposed, but until now the clinical introduction of such corrections remains unreported. In November 2013, the authors have clinically implemented a previously proposed image lag correction on all of their machines at their main site in Amsterdam. The purpose of this study was to retrospectively evaluate themore » effect of the correction on the quality of CBCT images and evaluate the required calibration frequency. Methods: Image lag was measured in five clinical CBCT systems (Elekta Synergy 4.6) using an in-house developed beam interrupting device that stops the x-ray beam midway through the data acquisition of an unattenuated beam for calibration. A triple exponential falling edge response was fitted to the measured data and used to correct image lag from projection images with an infinite response. This filter, including an extrapolation for saturated pixels, was incorporated in the authors’ in-house developed clinical CBCT reconstruction software. To investigate the short-term stability of the lag and associated parameters, a series of five image lag measurement over a period of three months was performed. For quantitative analysis, the authors have retrospectively selected ten patients treated in the pelvic region. The apparent contrast was quantified in polar coordinates for scans reconstructed using the parameters obtained from different dates with and without saturation handling. Results: Visually, the radar artifact was minimal in scans reconstructed using image lag correction especially when saturation handling was used. In patient imaging, there was a significant reduction of the apparent contrast from 43

  13. Respiratory-gated time-of-flight PET/CT during whole-body scan for lung lesions: feasibility in a routine clinical setting and quantitative analysis.

    PubMed

    Suzawa, Naohisa; Ichikawa, Yasutaka; Ishida, Masaki; Tomita, Yoya; Nakayama, Ryohei; Sakuma, Hajime

    2016-12-01

    To demonstrate the feasibility of respiratory gating during whole-body scan for lung lesions in routine 18 F-FDG PET/CT examinations using a time-of-flight (TOF)-capable scanner to determine the effect of respiratory gating on reduction of both misregistration (between CT and PET) and image blurring, and on improvement of the maximum standardized uptake value (SUVmax). Patients with lung lesions who received FDG PET/CT were prospectively studied. Misregistration, volume of PET (Vp), and SUVmax were compared between ungated and gated images. The difference in respiratory gating effects was compared between lesions located in the upper or middle lobes (UML) and the lower lobe (LL). The correlation between three parameters (% change in misregistration, % change in Vp, and lesion size) and % change in SUVmax was analyzed. The study population consisted of 60 patients (37 males, 23 females; age 68 ± 12 years) with lung lesions (2.5 ± 1.7 cm). Fifty-eight out of sixty respiratory gating studies were successfully completed with a total scan time of 20.9 ± 1.9 min. Eight patients' data were not suitable for analysis, while the remaining 50 patients' data were analyzed. Respiratory gating reduced both misregistration by 21.4 % (p < 0.001) and Vp by 14.2 % (p < 0.001). The SUVmax of gated images improved by 14.8 % (p < 0.001). The % change in misregistration, Vp, and SUVmax by respiratory gating tended to be larger in LL lesions than in UML lesions. The correlation with % change in SUVmax was stronger in % change in Vp (r = 0.57) than % change in misregistration (r = 0.35). There was no statistically significant correlation between lesion size and % change in SUVmax (r = -0.20). Respiratory gating during whole-body scan in routine TOF PET/CT examinations is feasible and can reduce both misregistration and PET image blurring, and improve the SUVmax of lung lesions located primarily in the LL.

  14. Multi-Frequency Intravascular Ultrasound (IVUS) Imaging

    PubMed Central

    Ma, Teng; Yu, Mingyue; Chen, Zeyu; Fei, Chunlong; Shung, K. Kirk; Zhou, Qifa

    2015-01-01

    Acute coronary syndrome (ACS) is frequently associated with the sudden rupture of a vulnerable atherosclerotic plaque within the coronary artery. Several unique physiological features, including a thin fibrous cap accompanied by a necrotic lipid core, are the targeted indicators for identifying the vulnerable plaques. Intravascular ultrasound (IVUS), a catheter-based imaging technology, has been routinely performed in clinics for more than 20 years to describe the morphology of the coronary artery and guide percutaneous coronary interventions. However, conventional IVUS cannot facilitate the risk assessment of ACS because of its intrinsic limitations, such as insufficient resolution. Renovation of the IVUS technology is essentially needed to overcome the limitations and enhance the coronary artery characterization. In this paper, a multi-frequency intravascular ultrasound (IVUS) imaging system was developed by incorporating a higher frequency IVUS transducer (80 to 150 MHz) with the conventional IVUS (30–50 MHz) system. The newly developed system maintains the advantage of deeply penetrating imaging with the conventional IVUS, while offering an improved higher resolution image with IVUS at a higher frequency. The prototyped multi-frequency catheter has a clinically compatible size of 0.95 mm and a favorable capability of automated image co-registration. In vitro human coronary artery imaging has demonstrated the feasibility and superiority of the multi-frequency IVUS imaging system to deliver a more comprehensive visualization of the coronary artery. This ultrasonic-only intravascular imaging technique, based on a moderate refinement of the conventional IVUS system, is not only cost-effective from the perspective of manufacturing and clinical practice, but also holds the promise of future translation into clinical benefits. PMID:25585394

  15. Imaging Intratumor Heterogeneity: Role in Therapy Response, Resistance, and Clinical Outcome

    PubMed Central

    O’Connor, James P.B.; Rose, Chris J.; Waterton, John C.; Carano, Richard A.D.; Parker, Geoff J.M.; Jackson, Alan

    2014-01-01

    Tumors exhibit genomic and phenotypic heterogeneity which has prognostic significance and may influence response to therapy. Imaging can quantify the spatial variation in architecture and function of individual tumors through quantifying basic biophysical parameters such as density or MRI signal relaxation rate; through measurements of blood flow, hypoxia, metabolism, cell death and other phenotypic features; and through mapping the spatial distribution of biochemical pathways and cell signaling networks. These methods can establish whether one tumor is more or less heterogeneous than another and can identify sub-regions with differing biology. In this article we review the image analysis methods currently used to quantify spatial heterogeneity within tumors. We discuss how analysis of intratumor heterogeneity can provide benefit over more simple biomarkers such as tumor size and average function. We consider how imaging methods can be integrated with genomic and pathology data, rather than be developed in isolation. Finally, we identify the challenges that must be overcome before measurements of intratumoral heterogeneity can be used routinely to guide patient care. PMID:25421725

  16. Molecular allergy diagnostics using multiplex assays: methodological and practical considerations for use in research and clinical routine: Part 21 of the Series Molecular Allergology.

    PubMed

    Jakob, Thilo; Forstenlechner, Peter; Matricardi, Paolo; Kleine-Tebbe, Jörg

    The availability of single allergens and their use in microarray technology enables the simultaneous determination of specific IgE (sIgE) to a multitude of different allergens (> 100) in a multiplex procedure requiring only minute amounts of serum. This allows extensive individual sensitization profiles to be determined from a single analysis. Combined with a patient's medical history, these profiles simplify identification of cross-reactivity; permit a more accurate estimation of the risk of severe reactions; and enable the indication for specific immunotherapy to be more precisely established, particularly in cases of polysensitization. Strictly speaking, a multiplex assay is not a single test, but instead more than 100 simultaneous tests. This places considerable demands on the production, quality assurance, and interpretation of data. The following chapter describes the multiplex test systems currently available and discusses their characteristics. Performance data are presented and the sIgE values obtained from multiplex and singleplex assays are compared. Finally, the advantages and limitations of molecular allergy diagnostics using multiplex assays in clinical routine are discussed, and innovative possibilities for clinical research are described. The multiplex diagnostic tests available for clinical routine have now become well established. The interpretation of test results is demanding, particularly since all individual results need to be checked for their plausibility and clinical relevance on the basis of previous history (patient history, clinical symptoms, challenge test results). There is still room for improvement in certain areas, for example with respect to the overall test sensitivity of the method, as well as the availability and quality of particular allergens. The current test systems are just the beginning of a continuous development that will influence and most likely change clinical allergology in the coming years.

  17. Telemedicine Interest for Routine Follow-Up Care Among Neurology Patients in Arkansas.

    PubMed

    Bashiri, Maryam; Greenfield, L John; Oliveto, Alison

    2016-06-01

    Teleneurology in Arkansas has been used primarily for management of acute stroke with a state-funded hub-and-spoke model allowing physicians at rural hospitals to access vascular neurologists in time to facilitate tissue plasminogen activator administration. Routine neurologic care has been provided only in small pilot studies. We wished to determine patient interest in participating in teleneurology for routine follow-up visits as well as demographic and medical factors associated with interest. New and established patients of the Neurology Outpatient Clinic at the University of Arkansas for Medical Sciences (UAMS) were surveyed between March 2011 and December 2012 to assess their interest in participating in teleneurology as well as potential factors associated with their interest. Of 1,441 respondents, 52.4% were interested in telemedicine. Of those interested versus uninterested in telemedicine, respectively, 68.9% versus 36.32% traveled more than 1 h to the clinic, 64.7% versus 35.3% had difficulty secondary to neurological conditions, 22.6% versus 6.8% had missed medical appointments due to travel problems, and 43.1% versus 9.4% had travel-imposed financial hardship. Telemedicine interest for routine follow-up visits was strong among patients at the UAMS Neurology Outpatient Clinic. Factors positively associated with interest included long travel distances, travel expenses, and transportation difficulties. These results suggest that implementing a telemedicine program for follow-up visits would be acceptable to neurology patients for routine ongoing care.

  18. Clinical experiences with an ASP model backup archive for PACS images

    NASA Astrophysics Data System (ADS)

    Liu, Brent J.; Cao, Fei; Documet, Luis; Huang, H. K.; Muldoon, Jean

    2003-05-01

    Last year we presented a Fault-Tolerant Backup Archive using an Application Service Provider (ASP) model for disaster recovery. The purpose of this paper is to update and provide clinical experiences related towards implementing the ASP model archive solution for short-term backup of clinical PACS image data as well as possible applications other than disaster recovery. The ASP backup archive provides instantaneous, automatic backup of acquired PACS image data and instantaneous recovery of stored PACS image data all at a low operational cost and with little human intervention. This solution can be used for a variety of scheduled and unscheduled downtimes that occur on the main PACS archive. A backup archive server with hierarchical storage was implemented offsite from the main PACS archive location. Clinical data from a hospital PACS is sent to this ASP storage server in parallel to the exams being archived in the main server. Initially, connectivity between the main archive and the ASP storage server is established via a T-1 connection. In the future, other more cost-effective means of connectivity will be researched such as the Internet 2. We have integrated the ASP model backup archive with a clinical PACS at Saint John's Health Center and has been operational for over 6 months. Pitfalls encountered during integration with a live clinical PACS and the impact to clinical workflow will be discussed. In addition, estimations of the cost of establishing such a solution as well as the cost charged to the users will be included. Clinical downtime scenarios, such as a scheduled mandatory downtime and an unscheduled downtime due to a disaster event to the main archive, were simulated and the PACS exams were sent successfully from the offsite ASP storage server back to the hospital PACS in less than 1 day. The ASP backup archive was able to recover PACS image data for comparison studies with no complex operational procedures. Furthermore, no image data loss was

  19. Quadruple inversion-recovery b-SSFP MRA of the abdomen: initial clinical validation.

    PubMed

    Atanasova, Iliyana P; Lim, Ruth P; Chandarana, Hersh; Storey, Pippa; Bruno, Mary T; Kim, Daniel; Lee, Vivian S

    2014-09-01

    The purpose of this study is to assess the image quality and diagnostic accuracy of non-contrast quadruple inversion-recovery balanced-SSFP MRA (QIR MRA) for detection of aortoiliac disease in a clinical population. QIR MRA was performed in 26 patients referred for routine clinical gadolinium-enhanced MRA (Gd-MRA) for known or suspected aortoiliac disease. Non-contrast images were independently evaluated for image quality and degree of stenosis by two radiologists, using consensus Gd-MRA as the reference standard. Hemodynamically significant stenosis (≥50%) was found in 10% (22/226) of all evaluable segments on Gd-MRA. The sensitivity and specificity for stenosis evaluation by QIR MRA for the two readers were 86%/86% and 95%/93% respectively. Negative predictive value and positive predictive value were 98%/98% and 63%/53% respectively. For stenosis evaluation of the aortoiliac region QIR MRA showed good agreement with the reference standard with high negative predictive value and a tendency to overestimate mild disease presumably due to the flow-dependence of the technique. QIR MRA could be a reasonable alternative to Gd-MRA for ruling out stenosis when contrast is contraindicated due to impaired kidney function or in patients who undergo abdominal MRA for screening purposes. Further work is necessary to improve performance and justify routine clinical use. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. The relationship between immediate relevant basic science knowledge and clinical knowledge: physiology knowledge and transthoracic echocardiography image interpretation.

    PubMed

    Nielsen, Dorte Guldbrand; Gotzsche, Ole; Sonne, Ole; Eika, Berit

    2012-10-01

    Two major views on the relationship between basic science knowledge and clinical knowledge stand out; the Two-world view seeing basic science and clinical science as two separate knowledge bases and the encapsulated knowledge view stating that basic science knowledge plays an overt role being encapsulated in the clinical knowledge. However, resent research has implied that a more complex relationship between the two knowledge bases exists. In this study, we explore the relationship between immediate relevant basic science (physiology) and clinical knowledge within a specific domain of medicine (echocardiography). Twenty eight medical students in their 3rd year and 45 physicians (15 interns, 15 cardiology residents and 15 cardiology consultants) took a multiple-choice test of physiology knowledge. The physicians also viewed images of a transthoracic echocardiography (TTE) examination and completed a checklist of possible pathologies found. A total score for each participant was calculated for the physiology test, and for all physicians also for the TTE checklist. Consultants scored significantly higher on the physiology test than did medical students and interns. A significant correlation between physiology test scores and TTE checklist scores was found for the cardiology residents only. Basic science knowledge of immediate relevance for daily clinical work expands with increased work experience within a specific domain. Consultants showed no relationship between physiology knowledge and TTE interpretation indicating that experts do not use basic science knowledge in routine daily practice, but knowledge of immediate relevance remains ready for use.

  1. Molecular imaging in neuroendocrine tumors: molecular uptake mechanisms and clinical results.

    PubMed

    Koopmans, Klaas P; Neels, Oliver N; Kema, Ido P; Elsinga, Philip H; Links, Thera P; de Vries, Elisabeth G E; Jager, Pieter L

    2009-09-01

    Neuroendocrine tumors can originate almost everywhere in the body and consist of a great variety of subtypes. This paper focuses on molecular imaging methods using nuclear medicine techniques in neuroendocrine tumors, coupling molecular uptake mechanisms of radiotracers with clinical results. A non-systematic review is presented on receptor based and metabolic imaging methods. Receptor-based imaging covers the molecular backgrounds of somatostatin, vaso-intestinal peptide (VIP), bombesin and cholecystokinin (CCK) receptors and their link with nuclear imaging. Imaging methods based on specific metabolic properties include meta-iodo-benzylguanide (MIBG) and dimercapto-sulphuric acid (DMSA-V) scintigraphy as well as more modern positron emission tomography (PET)-based methods using radio-labeled analogues of amino acids, glucose, dihydroxyphenylalanine (DOPA), dopamine and tryptophan. Diagnostic sensitivities are presented for each imaging method and for each neuroendocrine tumor subtype. Finally, a Forest plot analysis of diagnostic performance is presented for each tumor type in order to provide a comprehensive overview for clinical use.

  2. Quantitative Medical Image Analysis for Clinical Development of Therapeutics

    NASA Astrophysics Data System (ADS)

    Analoui, Mostafa

    There has been significant progress in development of therapeutics for prevention and management of several disease areas in recent years, leading to increased average life expectancy, as well as of quality of life, globally. However, due to complexity of addressing a number of medical needs and financial burden of development of new class of therapeutics, there is a need for better tools for decision making and validation of efficacy and safety of new compounds. Numerous biological markers (biomarkers) have been proposed either as adjunct to current clinical endpoints or as surrogates. Imaging biomarkers are among rapidly increasing biomarkers, being examined to expedite effective and rational drug development. Clinical imaging often involves a complex set of multi-modality data sets that require rapid and objective analysis, independent of reviewer's bias and training. In this chapter, an overview of imaging biomarkers for drug development is offered, along with challenges that necessitate quantitative and objective image analysis. Examples of automated and semi-automated analysis approaches are provided, along with technical review of such methods. These examples include the use of 3D MRI for osteoarthritis, ultrasound vascular imaging, and dynamic contrast enhanced MRI for oncology. Additionally, a brief overview of regulatory requirements is discussed. In conclusion, this chapter highlights key challenges and future directions in this area.

  3. Design of a Web-tool for diagnostic clinical trials handling medical imaging research.

    PubMed

    Baltasar Sánchez, Alicia; González-Sistal, Angel

    2011-04-01

    New clinical studies in medicine are based on patients and controls using different imaging diagnostic modalities. Medical information systems are not designed for clinical trials employing clinical imaging. Although commercial software and communication systems focus on storage of image data, they are not suitable for storage and mining of new types of quantitative data. We sought to design a Web-tool to support diagnostic clinical trials involving different experts and hospitals or research centres. The image analysis of this project is based on skeletal X-ray imaging. It involves a computerised image method using quantitative analysis of regions of interest in healthy bone and skeletal metastases. The database is implemented with ASP.NET 3.5 and C# technologies for our Web-based application. For data storage, we chose MySQL v.5.0, one of the most popular open source databases. User logins were necessary, and access to patient data was logged for auditing. For security, all data transmissions were carried over encrypted connections. This Web-tool is available to users scattered at different locations; it allows an efficient organisation and storage of data (case report form) and images and allows each user to know precisely what his task is. The advantages of our Web-tool are as follows: (1) sustainability is guaranteed; (2) network locations for collection of data are secured; (3) all clinical information is stored together with the original images and the results derived from processed images and statistical analysis that enable us to perform retrospective studies; (4) changes are easily incorporated because of the modular architecture; and (5) assessment of trial data collected at different sites is centralised to reduce statistical variance.

  4. Development of a novel imaging informatics-based system with an intelligent workflow engine (IWEIS) to support imaging-based clinical trials

    PubMed Central

    Wang, Ximing; Liu, Brent J; Martinez, Clarisa; Zhang, Xuejun; Winstein, Carolee J

    2015-01-01

    Imaging based clinical trials can benefit from a solution to efficiently collect, analyze, and distribute multimedia data at various stages within the workflow. Currently, the data management needs of these trials are typically addressed with custom-built systems. However, software development of the custom- built systems for versatile workflows can be resource-consuming. To address these challenges, we present a system with a workflow engine for imaging based clinical trials. The system enables a project coordinator to build a data collection and management system specifically related to study protocol workflow without programming. Web Access to DICOM Objects (WADO) module with novel features is integrated to further facilitate imaging related study. The system was initially evaluated by an imaging based rehabilitation clinical trial. The evaluation shows that the cost of the development of system can be much reduced compared to the custom-built system. By providing a solution to customize a system and automate the workflow, the system will save on development time and reduce errors especially for imaging clinical trials. PMID:25870169

  5. Wireless remote control clinical image workflow: utilizing a PDA for offsite distribution

    NASA Astrophysics Data System (ADS)

    Liu, Brent J.; Documet, Luis; Documet, Jorge; Huang, H. K.; Muldoon, Jean

    2004-04-01

    Last year we presented in RSNA an application to perform wireless remote control of PACS image distribution utilizing a handheld device such as a Personal Digital Assistant (PDA). This paper describes the clinical experiences including workflow scenarios of implementing the PDA application to route exams from the clinical PACS archive server to various locations for offsite distribution of clinical PACS exams. By utilizing this remote control application, radiologists can manage image workflow distribution with a single wireless handheld device without impacting their clinical workflow on diagnostic PACS workstations. A PDA application was designed and developed to perform DICOM Query and C-Move requests by a physician from a clinical PACS Archive to a CD-burning device for automatic burning of PACS data for the distribution to offsite. In addition, it was also used for convenient routing of historical PACS exams to the local web server, local workstations, and teleradiology systems. The application was evaluated by radiologists as well as other clinical staff who need to distribute PACS exams to offsite referring physician"s offices and offsite radiologists. An application for image workflow management utilizing wireless technology was implemented in a clinical environment and evaluated. A PDA application was successfully utilized to perform DICOM Query and C-Move requests from the clinical PACS archive to various offsite exam distribution devices. Clinical staff can utilize the PDA to manage image workflow and PACS exam distribution conveniently for offsite consultations by referring physicians and radiologists. This solution allows the radiologist to expand their effectiveness in health care delivery both within the radiology department as well as offisite by improving their clinical workflow.

  6. CERES: A Set of Automated Routines for Echelle Spectra

    NASA Astrophysics Data System (ADS)

    Brahm, Rafael; Jordán, Andrés; Espinoza, Néstor

    2017-03-01

    We present the Collection of Elemental Routines for Echelle Spectra (CERES). These routines were developed for the construction of automated pipelines for the reduction, extraction, and analysis of spectra acquired with different instruments, allowing the obtention of homogeneous and standardized results. This modular code includes tools for handling the different steps of the processing: CCD image reductions; identification and tracing of the echelle orders; optimal and rectangular extraction; computation of the wavelength solution; estimation of radial velocities; and rough and fast estimation of the atmospheric parameters. Currently, CERES has been used to develop automated pipelines for 13 different spectrographs, namely CORALIE, FEROS, HARPS, ESPaDOnS, FIES, PUCHEROS, FIDEOS, CAFE, DuPont/Echelle, Magellan/Mike, Keck/HIRES, Magellan/PFS, and APO/ARCES, but the routines can be easily used to deal with data coming from other spectrographs. We show the high precision in radial velocity that CERES achieves for some of these instruments, and we briefly summarize some results that have already been obtained using the CERES pipelines.

  7. Promoting early presentation of breast cancer in older women: sustained effect of an intervention to promote breast cancer awareness in routine clinical practice.

    PubMed

    Dodd, Rachael H; Forster, Alice S; Sellars, Sarah; Patnick, Julietta; Ramirez, Amanda J; Forbes, Lindsay J L

    2017-06-05

    Older women have poorer survival from breast cancer, which may be at least partly due to poor breast cancer awareness leading to delayed presentation and more advanced stage at diagnosis. In a randomised trial, an intervention to promote early presentation of breast cancer in older women increased breast cancer awareness at 1 year compared with usual care (24 versus 4%). We examined its effectiveness in routine clinical practice. We piloted the intervention delivered by practising health professionals to women aged about 70 in four breast screening services. We measured the effect on breast cancer awareness at 1 year compared with comparison services, where women did not receive the intervention. At 1 year, 25% of women in pilot services were breast cancer aware compared with 4% in comparison services (p = 0.001). The components of breast cancer awareness were knowledge of breast cancer non-lump symptoms (pilot: 63% vs comparison: 82% at 1 year; OR = 2.56, 95% CI 1.92-3.42), knowledge of age related risk (pilot: 8% vs comparison: 36% at 1 year; OR = 5.56, 95% CI 4.0-7.74) and reported breast checking (pilot: 70% vs comparison: 78% at 1 year; OR = 1.49, 95% CI 1.13-1.96). The intervention may be as effective in routine clinical practice as in a randomised controlled trial. This intervention has the potential to reduce patient delay in the diagnosis of breast cancer in older women. The PEP trial was registered with the International Standard Registered Clinical/soCial sTudy Number (ISRCTN) as a clinical trial ( ISRCTN31994827 ) on 3rd October 2007.

  8. Current Awareness and Use of the Strain Echocardiography in Routine Clinical Practices: Result of a Nationwide Survey in Korea.

    PubMed

    Lee, Ju-Hee; Park, Jae-Hyeong; Park, Seung Woo; Kim, Woo-Shik; Sohn, Il Suk; Chin, Jung Yeon; Cho, Jung Sun; Youn, Ho-Joong; Jung, Hae Ok; Lee, Sun Hwa; Kim, Seong-Hwan; Chung, Wook-Jin; Shim, Chi Young; Jeong, Jin-Won; Choi, Eui-Young; Rim, Se-Joong; Kim, Jang-Young; Kim, Kye Hun; Shin, Joon-Han; Kim, Dae-Hee; Jeon, Ung; Choi, Jung Hyun; Kim, Yong-Jin; Joo, Seung Jae; Kim, Ki-Hong; Cho, Kyoung Im; Cho, Goo-Yeong

    2017-09-01

    Because conventional echocardiographic parameters have several limitations, strain echocardiography has often been introduced in clinical practice. However, there are also obstacles in using it in clinical practice. Therefore, we wanted to find the current status of awareness on using strain echocardiography in Korea. We conducted a nationwide survey to evaluate current use and awareness of strain echocardiography from the members of the Korean Society of Echocardiography. We gathered total 321 questionnaires from 25 cardiology centers in Korea. All participants were able to perform or interpret echocardiographic examinations. All participating institutions performed strain echocardiography. Most of our study participants (97%) were aware of speckle tracking echocardiography and 185 (58%) performed it for clinical and research purposes. Two-dimensional strain echocardiography was the most commonly used modality and left ventricle (LV) was the most commonly used cardiac chamber (99%) for clinical purposes. Most of the participants (89%) did not think LV strain can replace LV ejection fraction (LVEF) in their clinical practice. The common reasons for not performing routine use of strain echocardiography was diversity of strain measurements and lack of normal reference value. Many participants had a favorable view of the future of strain echocardiography. Most of our study participants were aware of strain echocardiography, and all institutions performed strain echocardiography for clinical and research purposes. However, they did not think the LV strain values could replace LVEF. The diversity of strain measurements and lack of normal reference values were common reasons for not using strain echocardiography in clinical practice.

  9. [Routine fluoroscopic investigations after primary bariatric surgery].

    PubMed

    Gärtner, D; Ernst, A; Fedtke, K; Jenkner, J; Schöttler, A; Reimer, P; Blüher, M; Schön, M R

    2016-03-01

    Staple line and anastomotic leakages are life-threatening complications after bariatric surgery. Upper gastrointestinal (GI) tract X-ray examination with oral administration of a water-soluble contrast agent can be used to detect leaks. The aim of this study was to evaluate the impact of routine upper GI tract fluoroscopy after primary bariatric surgery. Between January 2009 and December 2014 a total of 658 bariatric interventions were carried out of which 442 were primary bariatric operations. Included in this single center study were 307 sleeve gastrectomies and 135 Roux-en-Y gastric bypasses. Up to December 2012 upper GI tract fluoroscopy was performed routinely between the first and third postoperative days and the detection of leakages was evaluated. In the investigation period 8 leakages (2.6 %) after sleeve gastrectomy, 1 anastomotic leakage in gastrojejunostomy and 1 in jejunojejunostomy after Roux-en-Y gastric bypass occurred. All patients developed clinical symptoms, such as abdominal pain, tachycardia or fever. In one case the leakage was detected by upper GI fluoroscopy and in nine cases radiological findings were unremarkable. No leakages were detected in asymptomatic patients. Routine upper GI fluoroscopy is not recommended for uneventful postoperative courses after primary bariatric surgery.

  10. How do youth with experience of violence victimization and/or risk drinking perceive routine inquiry about violence and alcohol consumption in Swedish youth clinics? A qualitative study.

    PubMed

    Palm, Anna; Danielsson, Ingela; Högberg, Ulf; Norbergh, Karl-Gustav

    2017-10-01

    To explore perceptions and experiences among youth who underwent structured questions about violence victimization and alcohol consumption when visiting Swedish youth clinics. This study is part of a larger research project examining the effect of including routine inquiry about violence victimization and alcohol consumption for youth visiting youth clinics. Fifteen youth with experiences of victimization and/or risk drinking (AUDIT-C≥5) were interviewed. Content analysis was used. The findings were grouped into three main categories: The first; "Disclosure - talking about violence" reflected the participants' experiences of being asked about victimization. Participants were in favor of routine inquiry about violence victimization, even when questions caused distress. The questions helped participants reflect on prior victimization and process what had happened to them. The second; "Influence on the life situation" demonstrated that many of the participants still were effected by prior victimization, but also how talking about violence sometimes led to the possibility of initiating change such as leaving a destructive relationship or starting therapy. In the third; "One's own alcohol consumption in black and white" participants considered it natural to be asked about alcohol consumption. However, most participants did not consider their drinking problematic, even when told they exceeded guidelines. They viewed risk drinking in terms of immediate consequences rather than in quantity or frequency of alcohol intake. Routine inquiry about violence victimization and risk drinking at youth clinics was well received. Questions about violence helped participants to interpret and process prior victimization and sometimes initiated change. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Automatic motion correction of clinical shoulder MR images

    NASA Astrophysics Data System (ADS)

    Manduca, Armando; McGee, Kiaran P.; Welch, Edward B.; Felmlee, Joel P.; Ehman, Richard L.

    1999-05-01

    A technique for the automatic correction of motion artifacts in MR images was developed. The algorithm uses only the raw (complex) data from the MR scanner, and requires no knowledge of the patient motion during the acquisition. It operates by searching over the space of possible patient motions and determining the motion which, when used to correct the image, optimizes the image quality. The performance of this algorithm was tested in coronal images of the rotator cuff in a series of 144 patients. A four observer comparison of the autocorrelated images with the uncorrected images demonstrated that motion artifacts were significantly reduced in 48% of the cases. The improvements in image quality were similar to those achieved with a previously reported navigator echo-based adaptive motion correction. The results demonstrate that autocorrelation is a practical technique for retrospectively reducing motion artifacts in a demanding clinical MRI application. It achieves performance comparable to a navigator based correction technique, which is significant because autocorrection does not require an imaging sequence that has been modified to explicitly track motion during acquisition. The approach is flexible and should be readily extensible to other types of MR acquisitions that are corrupted by global motion.

  12. What is the value of routinely testing full blood count, electrolytes and urea, and pulmonary function tests before elective surgery in patients with no apparent clinical indication and in subgroups of patients with common comorbidities: a systematic review of the clinical and cost-effective literature.

    PubMed

    Czoski-Murray, C; Lloyd Jones, M; McCabe, C; Claxton, K; Oluboyede, Y; Roberts, J; Nicholl, J P; Rees, A; Reilly, C S; Young, D; Fleming, T

    2012-12-01

    The evidence base which supported the National Institute for Health and Clinical Excellence (NICE) published Clinical Guideline 3 was limited and 50% was graded as amber. However, the use of tests as part of pre-operative work-up remains a low-cost but high-volume activity within the NHS, with substantial resource implications. The objective of this study was to identify, evaluate and synthesise the published evidence on the clinical effectiveness and cost-effectiveness of the routine use of three tests, full blood counts (FBCs), urea and electrolytes tests (U&Es) and pulmonary function tests, in the pre-operative work-up of otherwise healthy patients undergoing minor or intermediate surgery in the NHS. The aims of this study were to estimate the clinical effectiveness and cost-effectiveness of routine pre-operative testing of FBC, electrolytes and renal function and pulmonary function in adult patients classified as American Society of Anaesthesiologists (ASA) grades 1 and 2 undergoing elective minor (grade 1) or intermediate (grade 2) surgical procedures; to compare NICE recommendations with current practice; to evaluate the cost-effectiveness of mandating or withdrawing each of these tests in this patient group; and to identify the expected value of information and whether or not it has value to the NHS in commissioning further primary research into the use of these tests in this group of patients. The following electronic bibliographic databases were searched: (1) BIOSIS; (2) Cumulative Index to Nursing and Allied Health Literature; (3) Cochrane Database of Systematic Reviews; (4) Cochrane Central Register of Controlled Trials; (5) EMBASE; (6) MEDLINE; (7) MEDLINE In-Process & Other Non-Indexed Citations; (8) NHS Database of Abstracts of Reviews of Effects; (9) NBS Health Technology Assessment Database; and (10) Science Citation Index. To identify grey and unpublished literature, the Cochrane Register of Controlled Trials, National Research Register Archive

  13. Magnetic field measurements of a clinical MR imager at 1.5 tesla

    NASA Astrophysics Data System (ADS)

    Muhech, A.; Tellez, I.; Esteva, M.; Marrufo, O.; Jimenez, L.; Vazquez, F.; Taboada, J.; Rodriguez, A. O.

    2012-10-01

    In the clinical environment is mandatory to run periodically measurements of uniformity of the magnetic field produced by the magnet to assure good image quality. The phase difference method was used to measure the magnetic field uniformity of the 1.5 T scanner of the Instituto Nacional de Neurologia y Neurocirugia MVS. The uniformity field values showed that the imager performance is reasonably good for clinical imaging. Some concern was raised since results may not be good enough for magnetic resonance spectroscopy runs.

  14. Is daily routine important for sleep? An investigation of social rhythms in a clinical insomnia population.

    PubMed

    Moss, Taryn G; Carney, Colleen E; Haynes, Patricia; Harris, Andrea L

    2015-02-01

    Social rhythms, also known as daily routines (e.g. exercise, of school or work, recreation, social activities), have been identified as potential time cues to help to regulate the biological clock. Past research has shown links between regularity and healthy sleep. This study examined the regularity and frequency of daytime activities in a clinical insomnia population and a good sleeper comparison group. Participants (N = 69) prospectively monitored their sleep and daily activities for a 2-week period. Although participants with insomnia and good sleepers had similar levels of activity, relative to good sleepers, those with insomnia were less regular in their activities. Findings from this study add to the growing number of studies that highlight the relative importance of the regularity of daytime activities on sleep. Accordingly, future research should test treatment components that focus on regulating daytime activities, which would likely improve treatment outcomes.

  15. Clinics in diagnostic imaging (168).

    PubMed

    Lai, Yusheng Keefe; Mahmood, Rameysh Danovani

    2016-05-01

    A 16-year-old Chinese male patient presented with constipation lasting five days, colicky abdominal pain, lethargy, weakness and body aches. He was able to pass flatus. Abdominal radiography showed a distended stomach causing inferior displacement of the transverse colon. Computed tomography revealed a dilated oesophagus, stomach and duodenum up to its third portion, with a short aortomesenteric distance and narrow angle. There was also consolidation in the lungs bilaterally. Based on the constellation of clinical and imaging findings, a diagnosis of superior mesenteric artery syndrome complicated by aspiration pneumonia was made. The patient was subsequently started on intravenous hydration, nasogastric tube aspiration and antibiotics. Following stabilisation of his acute condition, a nasojejunal feeding tube was inserted and a feeding plan was implemented to promote weight gain. The clinical presentation, differentials, diagnosis and treatment of superior mesenteric artery syndrome are discussed. Copyright: © Singapore Medical Association.

  16. Operational experience with DICOM for the clinical specialties in the healthcare enterprise

    NASA Astrophysics Data System (ADS)

    Kuzmak, Peter M.; Dayhoff, Ruth E.

    2004-04-01

    A number of clinical specialties routinely use images in treating patients, for example ophthalmology, dentistry, cardiology, endoscopy, and surgery. These images are captured by a variety of commercial digital image acquisition systems. The US Department of Veterans Affairs has been working for several years on advancing the use of the Digital Imaging and Communications in Medicine (DICOM) Standard in these clinical specialties. This is an effort that has involved several facets: (1) working with the vendors to ensure that they satisfy existing DICOM requirements, (2) developing interface software to the VistA hospital information system (HIS), (3) field testing DICOM systems, (4) deploying these DICOM interfaces nation-wide to all VA medical centers, (5) working with the healthcare providers using the system, and (6) participating in the DICOM working groups to improve the standard. The VA is now beginning to develop clinical applications that make use of the DICOM interfaces in the clinical specialties. The first of these will be in ophthalmology to remotely screen patients for diabetic retinopathy.

  17. Prostate cancer localization with endorectal MR imaging and MR spectroscopic imaging: effect of clinical data on reader accuracy.

    PubMed

    Dhingsa, Rajpal; Qayyum, Aliya; Coakley, Fergus V; Lu, Ying; Jones, Kirk D; Swanson, Mark G; Carroll, Peter R; Hricak, Hedvig; Kurhanewicz, John

    2004-01-01

    To determine the effect of digital rectal examination findings, sextant biopsy results, and prostate-specific antigen (PSA) levels on reader accuracy in the localization of prostate cancer with endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging. This was a retrospective study of 37 patients (mean age, 57 years) with biopsy-proved prostate cancer. Transverse T1-weighted, transverse high-spatial-resolution, and coronal T2-weighted MR images and MR spectroscopic images were obtained. Two independent readers, unaware of clinical data, recorded the size and location of suspicious peripheral zone tumor nodules on a standardized diagram of the prostate. Readers also recorded their degree of diagnostic confidence for each nodule on a five-point scale. Both readers repeated this interpretation with knowledge of rectal examination findings, sextant biopsy results, and PSA level. Step-section histopathologic findings were the reference standard. Logistic regression analysis with generalized estimating equations was used to correlate tumor detection with clinical data, and alternative free-response receiver operating characteristic (AFROC) curve analysis was used to examine the overall effect of clinical data on all positive results. Fifty-one peripheral zone tumor nodules were identified at histopathologic evaluation. Logistic regression analysis showed awareness of clinical data significantly improved tumor detection rate (P <.02) from 15 to 19 nodules for reader 1 and from 13 to 19 nodules for reader 2 (27%-37% overall) by using both size and location criteria. AFROC analysis showed no significant change in overall reader performance because there was an associated increase in the number of false-positive findings with awareness of clinical data, from 11 to 21 for reader 1 and from 16 to 25 for reader 2. Awareness of clinical data significantly improves reader detection of prostate cancer nodules with endorectal MR imaging and MR spectroscopic imaging

  18. The role of PET quantification in cardiovascular imaging.

    PubMed

    Slomka, Piotr; Berman, Daniel S; Alexanderson, Erick; Germano, Guido

    2014-08-01

    Positron Emission Tomography (PET) has several clinical and research applications in cardiovascular imaging. Myocardial perfusion imaging with PET allows accurate global and regional measurements of myocardial perfusion, myocardial blood flow and function at stress and rest in one exam. Simultaneous assessment of function and perfusion by PET with quantitative software is currently the routine practice. Combination of ejection fraction reserve with perfusion information may improve the identification of severe disease. The myocardial viability can be estimated by quantitative comparison of fluorodeoxyglucose ( 18 FDG) and rest perfusion imaging. The myocardial blood flow and coronary flow reserve measurements are becoming routinely included in the clinical assessment due to enhanced dynamic imaging capabilities of the latest PET/CT scanners. Absolute flow measurements allow evaluation of the coronary microvascular dysfunction and provide additional prognostic and diagnostic information for coronary disease. Standard quantitative approaches to compute myocardial blood flow from kinetic PET data in automated and rapid fashion have been developed for 13 N-ammonia, 15 O-water and 82 Rb radiotracers. The agreement between software methods available for such analysis is excellent. Relative quantification of 82 Rb PET myocardial perfusion, based on comparisons to normal databases, demonstrates high performance for the detection of obstructive coronary disease. New tracers, such as 18 F-flurpiridaz may allow further improvements in the disease detection. Computerized analysis of perfusion at stress and rest reduces the variability of the assessment as compared to visual analysis. PET quantification can be enhanced by precise coregistration with CT angiography. In emerging clinical applications, the potential to identify vulnerable plaques by quantification of atherosclerotic plaque uptake of 18 FDG and 18 F-sodium fluoride tracers in carotids, aorta and coronary arteries

  19. Dermatological Feasibility of Multimodal Facial Color Imaging Modality for Cross-Evaluation of Facial Actinic Keratosis

    PubMed Central

    Bae, Youngwoo; Son, Taeyoon; Nelson, J. Stuart; Kim, Jae-Hong; Choi, Eung Ho; Jung, Byungjo

    2010-01-01

    Background/Purpose Digital color image analysis is currently considered as a routine procedure in dermatology. In our previous study, a multimodal facial color imaging modality (MFCIM), which provides a conventional, parallel- and cross-polarization, and fluorescent color image, was introduced for objective evaluation of various facial skin lesions. This study introduces a commercial version of MFCIM, DermaVision-PRO, for routine clinical use in dermatology and demonstrates its dermatological feasibility for cross-evaluation of skin lesions. Methods/Results Sample images of subjects with actinic keratosis or non-melanoma skin cancers were obtained at four different imaging modes. Various image analysis methods were applied to cross-evaluate the skin lesion and, finally, extract valuable diagnostic information. DermaVision-PRO is potentially a useful tool as an objective macroscopic imaging modality for quick prescreening and cross-evaluation of facial skin lesions. Conclusion DermaVision-PRO may be utilized as a useful tool for cross-evaluation of widely distributed facial skin lesions and an efficient database management of patient information. PMID:20923462

  20. Image-Guided Surgery using Invisible Near-Infrared Light: Fundamentals of Clinical Translation

    PubMed Central

    Gioux, Sylvain; Choi, Hak Soo; Frangioni, John V.

    2011-01-01

    The field of biomedical optics has matured rapidly over the last decade and is poised to make a significant impact on patient care. In particular, wide-field (typically > 5 cm), planar, near-infrared (NIR) fluorescence imaging has the potential to revolutionize human surgery by providing real-time image guidance to surgeons for tissue that needs to be resected, such as tumors, and tissue that needs to be avoided, such as blood vessels and nerves. However, to become a clinical reality, optimized imaging systems and NIR fluorescent contrast agents will be needed. In this review, we introduce the principles of NIR fluorescence imaging, analyze existing NIR fluorescence imaging systems, and discuss the key parameters that guide contrast agent development. We also introduce the complexities surrounding clinical translation using our experience with the Fluorescence-Assisted Resection and Exploration (FLARE™) imaging system as an example. Finally, we introduce state-of-the-art optical imaging techniques that might someday improve image-guided surgery even further. PMID:20868625

  1. Segmentation of white matter hyperintensities using convolutional neural networks with global spatial information in routine clinical brain MRI with none or mild vascular pathology.

    PubMed

    Rachmadi, Muhammad Febrian; Valdés-Hernández, Maria Del C; Agan, Maria Leonora Fatimah; Di Perri, Carol; Komura, Taku

    2018-06-01

    We propose an adaptation of a convolutional neural network (CNN) scheme proposed for segmenting brain lesions with considerable mass-effect, to segment white matter hyperintensities (WMH) characteristic of brains with none or mild vascular pathology in routine clinical brain magnetic resonance images (MRI). This is a rather difficult segmentation problem because of the small area (i.e., volume) of the WMH and their similarity to non-pathological brain tissue. We investigate the effectiveness of the 2D CNN scheme by comparing its performance against those obtained from another deep learning approach: Deep Boltzmann Machine (DBM), two conventional machine learning approaches: Support Vector Machine (SVM) and Random Forest (RF), and a public toolbox: Lesion Segmentation Tool (LST), all reported to be useful for segmenting WMH in MRI. We also introduce a way to incorporate spatial information in convolution level of CNN for WMH segmentation named global spatial information (GSI). Analysis of covariance corroborated known associations between WMH progression, as assessed by all methods evaluated, and demographic and clinical data. Deep learning algorithms outperform conventional machine learning algorithms by excluding MRI artefacts and pathologies that appear similar to WMH. Our proposed approach of incorporating GSI also successfully helped CNN to achieve better automatic WMH segmentation regardless of network's settings tested. The mean Dice Similarity Coefficient (DSC) values for LST-LGA, SVM, RF, DBM, CNN and CNN-GSI were 0.2963, 0.1194, 0.1633, 0.3264, 0.5359 and 5389 respectively. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  2. Is heart rate variability better than routine vital signs for prehospital identification of major hemorrhage?

    PubMed

    Edla, Shwetha; Reisner, Andrew T; Liu, Jianbo; Convertino, Victor A; Carter, Robert; Reifman, Jaques

    2015-02-01

    During initial assessment of trauma patients, metrics of heart rate variability (HRV) have been associated with high-risk clinical conditions. Yet, despite numerous studies, the potential of HRV to improve clinical outcomes remains unclear. Our objective was to evaluate whether HRV metrics provide additional diagnostic information, beyond routine vital signs, for making a specific clinical assessment: identification of hemorrhaging patients who receive packed red blood cell (PRBC) transfusion. Adult prehospital trauma patients were analyzed retrospectively, excluding those who lacked a complete set of reliable vital signs and a clean electrocardiogram for computation of HRV metrics. We also excluded patients who did not survive to admission. The primary outcome was hemorrhagic injury plus different PRBC transfusion volumes. We performed multivariate regression analysis using HRV metrics and routine vital signs to test the hypothesis that HRV metrics could improve the diagnosis of hemorrhagic injury plus PRBC transfusion vs routine vital signs alone. As univariate predictors, HRV metrics in a data set of 402 subjects had comparable areas under receiver operating characteristic curves compared with routine vital signs. In multivariate regression models containing routine vital signs, HRV parameters were significant (P<.05) but yielded areas under receiver operating characteristic curves with minimal, nonsignificant improvements (+0.00 to +0.05). A novel diagnostic test should improve diagnostic thinking and allow for better decision making in a significant fraction of cases. Our findings do not support that HRV metrics add value over routine vital signs in terms of prehospital identification of hemorrhaging patients who receive PRBC transfusion. Published by Elsevier Inc.

  3. Ultrashort Microwave-Pumped Real-Time Thermoacoustic Breast Tumor Imaging System.

    PubMed

    Ye, Fanghao; Ji, Zhong; Ding, Wenzheng; Lou, Cunguang; Yang, Sihua; Xing, Da

    2016-03-01

    We report the design of a real-time thermoacoustic (TA) scanner dedicated to imaging deep breast tumors and investigate its imaging performance. The TA imaging system is composed of an ultrashort microwave pulse generator and a ring transducer array with 384 elements. By vertically scanning the transducer array that encircles the breast phantom, we achieve real-time, 3D thermoacoustic imaging (TAI) with an imaging speed of 16.7 frames per second. The stability of the microwave energy and its distribution in the cling-skin acoustic coupling cup are measured. The results indicate that there is a nearly uniform electromagnetic field in each XY-imaging plane. Three plastic tubes filled with salt water are imaged dynamically to evaluate the real-time performance of our system, followed by 3D imaging of an excised breast tumor embedded in a breast phantom. Finally, to demonstrate the potential for clinical applications, the excised breast of a ewe embedded with an ex vivo human breast tumor is imaged clearly with a contrast of about 1:2.8. The high imaging speed, large field of view, and 3D imaging performance of our dedicated TAI system provide the potential for clinical routine breast screening.

  4. Utilizing data grid architecture for the backup and recovery of clinical image data.

    PubMed

    Liu, Brent J; Zhou, M Z; Documet, J

    2005-01-01

    Grid Computing represents the latest and most exciting technology to evolve from the familiar realm of parallel, peer-to-peer and client-server models. However, there has been limited investigation into the impact of this emerging technology in medical imaging and informatics. In particular, PACS technology, an established clinical image repository system, while having matured significantly during the past ten years, still remains weak in the area of clinical image data backup. Current solutions are expensive or time consuming and the technology is far from foolproof. Many large-scale PACS archive systems still encounter downtime for hours or days, which has the critical effect of crippling daily clinical operations. In this paper, a review of current backup solutions will be presented along with a brief introduction to grid technology. Finally, research and development utilizing the grid architecture for the recovery of clinical image data, in particular, PACS image data, will be presented. The focus of this paper is centered on applying a grid computing architecture to a DICOM environment since DICOM has become the standard for clinical image data and PACS utilizes this standard. A federation of PACS can be created allowing a failed PACS archive to recover its image data from others in the federation in a seamless fashion. The design reflects the five-layer architecture of grid computing: Fabric, Resource, Connectivity, Collective, and Application Layers. The testbed Data Grid is composed of one research laboratory and two clinical sites. The Globus 3.0 Toolkit (Co-developed by the Argonne National Laboratory and Information Sciences Institute, USC) for developing the core and user level middleware is utilized to achieve grid connectivity. The successful implementation and evaluation of utilizing data grid architecture for clinical PACS data backup and recovery will provide an understanding of the methodology for using Data Grid in clinical image data backup for

  5. Clinical and imaging features in different inner border-zone infarct patterns.

    PubMed

    Wang, Yujie; Wang, Jian

    2015-03-01

    The clinical and imaging features of different inner border-zone infarct patterns, corona radiata (CR) and centrum semiovale (CSO), is not quiet clear. Both are mostly reported together in previous studies. We intended to observe their clinical and imaging features. We observed 83 patients-47 cases with CR infarct lesion pattern and 36 cases with CSO. The lesion patterns were determined by diffusion-weighted imaging. Basic, clinical and radiologic features were compared between the patients with CR and CSO infarct lesion patterns. There was no significant difference between CR and CSO infarct patterns in terms of risk factors. However, patients with CR infarct had a higher initial National Institutes of Health Stroke Scale (NIHSS) score at admission (5.2 ± 2.3) than with CSO (3.9 ± 2.0, p = 0.009). Early clinical deterioration (OR, 2.42; 95% CI, 1.12-5.21; p = 0.024) and middle cerebral artery (MCA) stenosis (OR, 10.31; 95% CI, 3.30-32.19; p < 0.0001) were independently associated with the CR infarct lesion pattern. Partial infarct lesion shape (OR, 5.95; 95% CI, 1.40-25.33; p = 0.016) and internal carotid artery (ICA) stenosis (OR, 5.28; 95% CI, 1.92-14.51; p = 0.001) were independently correlated with the CSO infarct lesion pattern. Although CR and CSO infarct patterns might share common etiology and mechanisms, their clinical and imaging features are different.

  6. Routine Angiographic Follow-Up versus Clinical Follow-Up after Percutaneous Coronary Intervention in Acute Myocardial Infarction

    PubMed Central

    Kim, Yong Hoon; Her, Ae-Young; Choi, Byoung Geol; Shim, Minsuk; Choi, Se Yeon; Byun, Jae Kyeong; Li, Hu; Kim, Woohyeun; Kang, Jun Hyuk; Choi, Jah Yeon; Park, Eun Jin; Park, Sung Hun; Lee, Sunki; Na, Jin Oh; Choi, Cheol Ung; Lim, Hong Euy; Kim, Eung Ju; Park, Chang Gyu; Seo, Hong Seog; Oh, Dong Joo

    2017-01-01

    Purpose Differences in the utility of routine angiographic follow-up (RAF) and clinical follow-up (CF) after percutaneous coronary intervention (PCI) in acute myocardial infarction (AMI) are not well understood. The present study aimed to compare the 3-year clinical outcomes of RAF and CF in AMI patients who underwent PCI with drug-eluting stents (DES). Materials and Methods A total of 774 consecutive AMI patients who underwent PCI with DES were enrolled. RAF was performed at 6 to 9 months after index PCI (n=425). The remaining patients were medically managed and clinically followed (n=349); symptom-driven events were captured. To adjust for any potential confounders, a propensity score matched analysis was performed using a logistic regression model, and two propensity-matched groups (248 pairs, n=496, C-statistic=0.739) were generated. Cumulative clinical outcomes up to 3 years were compared between RAF and CF groups. Results During the 3-year follow-up period, the cumulative incidences of revascularization [target lesion revascularization: hazard ratio (HR), 2.40; 95% confidence interval (CI), 1.18–4.85; p=0.015, target vessel revascularization (TVR): HR, 3.33; 95% CI, 1.69–6.58; p=0.001, non-TVR: HR, 5.64; 95% CI, 1.90–16.6; p=0.002] and major adverse cardiac events (MACE; HR, 3.32; 95% CI, 1.92–5.73; p<0.001) were significantly higher in the RAF group than the CF group. However, the 3-year incidences of death and myocardial infarction were not different between the two groups. Conclusion RAF following index PCI with DES in AMI patients was associated with increased incidences of revascularization and MACE. Therefore, CF seems warranted for asymptomatic patients after PCI for AMI. PMID:28540983

  7. Multiplex Staining by Sequential Immunostaining and Antibody Removal on Routine Tissue Sections.

    PubMed

    Bolognesi, Maddalena Maria; Manzoni, Marco; Scalia, Carla Rossana; Zannella, Stefano; Bosisio, Francesca Maria; Faretta, Mario; Cattoretti, Giorgio

    2017-08-01

    Multiplexing, labeling for multiple immunostains in the very same cell or tissue section in situ, has raised considerable interest. The methods proposed include the use of labeled primary antibodies, spectral separation of fluorochromes, bleaching of the fluorophores or chromogens, blocking of previous antibody layers, all in various combinations. The major obstacles to the diffusion of this technique are high costs in custom antibodies and instruments, low throughput, and scarcity of specialized skills or facilities. We have validated a method based on common primary and secondary antibodies and diffusely available fluorescent image scanners. It entails rounds of four-color indirect immunofluorescence, image acquisition, and removal (stripping) of the antibodies, before another stain is applied. The images are digitally registered and the autofluorescence is subtracted. Removal of antibodies is accomplished by disulfide cleavage and a detergent or by a chaotropic salt treatment, this latter followed by antigen refolding. More than 30 different antibody stains can be applied to one single section from routinely fixed and embedded tissue. This method requires a modest investment in hardware and materials and uses freeware image analysis software. Multiplexing on routine tissue sections is a high throughput tool for in situ characterization of neoplastic, reactive, inflammatory, and normal cells.

  8. Gorlin-Goltz syndrome: incidental finding on routine ct scan following car accident

    PubMed Central

    2009-01-01

    Introduction Gorlin-Goltz syndrome is a rare hereditary disease. Pathogenesis of the syndrome is attributed to abnormalities in the long arm of chromosome 9 (q22.3-q31) and loss or mutations of human patched gene (PTCH1 gene). Multiple basal cell carcinomas (BCCs), odontogenic keratocysts, skeletal abnormalities, hyperkeratosis of palms and soles, intracranial ectopic calcifications of the falx cerebri and facial dysmorphism are considered the main clinical features. Diagnosis is based upon established major and minor clinical and radiological criteria and ideally confirmed by DNA analysis. Because of the different systems affected, a multidisciplinary approach team of various experts is required for a successful management. Case presentation We report the case of a 19 year-old female who was involved in a car accident and found to present imaging findings of Gorlin-Goltz syndrome during a routine whole body computed tomography (CT) scan in order to exclude traumatic injuries. Conclusion Radiologic findings of the syndrome are easily identifiable on CT scans and may prompt to early verification of the disease, which is very important for regular follow-up and better survival rates from the co-existent diseases. PMID:20062724

  9. Gorlin-Goltz syndrome: incidental finding on routine ct scan following car accident.

    PubMed

    Kalogeropoulou, Christina; Zampakis, Petros; Kazantzi, Santra; Kraniotis, Pantelis; Mastronikolis, Nicholas S

    2009-11-25

    Gorlin-Goltz syndrome is a rare hereditary disease. Pathogenesis of the syndrome is attributed to abnormalities in the long arm of chromosome 9 (q22.3-q31) and loss or mutations of human patched gene (PTCH1 gene). Multiple basal cell carcinomas (BCCs), odontogenic keratocysts, skeletal abnormalities, hyperkeratosis of palms and soles, intracranial ectopic calcifications of the falx cerebri and facial dysmorphism are considered the main clinical features. Diagnosis is based upon established major and minor clinical and radiological criteria and ideally confirmed by DNA analysis. Because of the different systems affected, a multidisciplinary approach team of various experts is required for a successful management. We report the case of a 19 year-old female who was involved in a car accident and found to present imaging findings of Gorlin-Goltz syndrome during a routine whole body computed tomography (CT) scan in order to exclude traumatic injuries. Radiologic findings of the syndrome are easily identifiable on CT scans and may prompt to early verification of the disease, which is very important for regular follow-up and better survival rates from the co-existent diseases.

  10. Photo acoustic imaging: technology, systems and market trends

    NASA Astrophysics Data System (ADS)

    Faucheux, Marc; d'Humières, Benoît; Cochard, Jacques

    2017-03-01

    Although the Photo Acoustic effect was observed by Graham Bell in 1880, the first applications (gas analysis) occurred in 1970's using the required energetic light pulses from lasers. During mid 1990's medical imaging research begun to use Photo Acoustic effect and in vivo images were obtained in mid-2000. Since 2009, the number of patent related to Photo Acoustic Imaging (PAI) has dramatically increased. PAI machines for pre-clinical and small animal imaging have been being used in a routine way for several years. Based on its very interesting features (non-ionizing radiation, noninvasive, high depth resolution ratio, scalability, moderate price) and because it is able to deliver not only anatomical, but functional and molecular information, PAI is a very promising clinical imaging modality. It penetrates deeper into tissue than OCT (Optical Coherence Tomography) and provides a higher resolution than ultrasounds. The PAI is one of the most growing imaging modality and some innovative clinical systems are planned to be on market in 2017. Our study analyzes the different approaches such as photoacoustic computed tomography, 3D photoacoustic microscopy, multispectral photoacoustic tomography and endoscopy with the recent and tremendous technological progress over the past decade: advances in image reconstruction algorithms, laser technology, ultrasound detectors and miniaturization. We analyze which medical domains and applications are the most concerned and explain what should be the forthcoming medical system in the near future. We segment the market in four parts: Components and R&D, pre-clinical, analytics, clinical. We analyzed what should be, quantitatively and qualitatively, the PAI medical markets in each segment and its main trends. We point out the market accessibility (patents, regulations, clinical evaluations, clinical acceptance, funding). In conclusion, we explain the main market drivers and challenges to overcome and give a road map for medical

  11. A preliminary study of simple voice assessment in a routine clinical setting to predict vocal cord paralysis after thyroid or parathyroid surgery.

    PubMed

    Hanna, B C; Brooker, D S

    2008-02-01

    To determine if a simple assessment of vocal cord function performed in a routine clinical setting can predict vocal cord paralysis on laryngoscopy in patients following thyroid or parathyroid surgery. Prospective observational cohort study of patients undergoing thyroid or parathyroid surgery. Vocal cord function was assessed in terms of an abnormality of voice or cough reported by the patient or detected by the examiner. Laryngoscopy was performed by indirect mirror examination or fibreoptic nasopharyngolaryngoscopy. Examiners included otolaryngology consultants, registrars, senior house officers and a general practitioner with a special interest in otolaryngology. The patient was often examined by a different clinician before and after surgery. Eighty-six patients participated in the study between August 2003 and July 2004. Eleven had a change in their voice postoperatively and one patient had difficulty coughing. Six of these patients had a vocal cord paralysis. A further five apparently asymptomatic patients had a vocal cord paralysis. The positive predictive value of voice assessment for vocal cord paralysis was 55%. In a routine clinical setting where the assessment of vocal cord function is often reported by different clinicians of varying experience at each patient attendance, the assessment of a patient's voice following thyroid or parathyroid surgery is not adequately predictive of vocal cord paralysis on indirect laryngoscopy or fibreoptic nasopharyngolaryngoscopy. Further study is required to determine reasons for this.

  12. Cyclophosphamide administration routine in autoimmune rheumatic diseases: a review.

    PubMed

    Teles, Kaian Amorim; Medeiros-Souza, Patricia; Lima, Francisco Aires Correa; Araújo, Bruno Gedeon de; Lima, Rodrigo Aires Correa

    Cyclophosphamide is an alkylating agent widely used for the treatment of malignant neoplasia and which can be used in the treatment of multiple rheumatic diseases. Medication administration errors may lead to its reduced efficacy or increased drug toxicity. Many errors occur in the administration of injectable drugs. The present study aimed at structuring a routine for cyclophosphamide use, as well as creating a document with pharmacotherapeutic guidelines for the patient. The routine is schematized in three phases: pre-chemotherapy, administration of cyclophosphamide, and post-chemotherapy, taking into account the drugs to be administered before and after cyclophosphamide in order to prevent adverse effects, including nausea and hemorrhagic cystitis. Adverse reactions can alter laboratory tests; thus, this routine included clinical management for changes in white blood cells, platelets, neutrophils, and sodium, including cyclophosphamide dose adjustment in the case of kidney disease. Cyclophosphamide is responsible for other rare - but serious - side effects, for instance, hepatotoxicity, severe hyponatremia and heart failure. Other adverse reactions include hair loss, amenorrhea and menopause. In this routine, we also entered guidelines to post-chemotherapy patients. The compatibility of injectable drugs with the vehicle used has been described, as well as stability and infusion times. The routine aimed at the rational use of cyclophosphamide, with prevention of adverse events and relapse episodes, factors that may burden the health care system. Copyright © 2016 Elsevier Editora Ltda. All rights reserved.

  13. Quantitative imaging of the human upper airway: instrument design and clinical studies

    NASA Astrophysics Data System (ADS)

    Leigh, M. S.; Armstrong, J. J.; Paduch, A.; Sampson, D. D.; Walsh, J. H.; Hillman, D. R.; Eastwood, P. R.

    2006-08-01

    Imaging of the human upper airway is widely used in medicine, in both clinical practice and research. Common imaging modalities include video endoscopy, X-ray CT, and MRI. However, no current modality is both quantitative and safe to use for extended periods of time. Such a capability would be particularly valuable for sleep research, which is inherently reliant on long observation sessions. We have developed an instrument capable of quantitative imaging of the human upper airway, based on endoscopic optical coherence tomography. There are no dose limits for optical techniques, and the minimally invasive imaging probe is safe for use in overnight studies. We report on the design of the instrument and its use in preliminary clinical studies, and we present results from a range of initial experiments. The experiments show that the instrument is capable of imaging during sleep, and that it can record dynamic changes in airway size and shape. This information is useful for research into sleep disorders, and potentially for clinical diagnosis and therapies.

  14. Routine intra-operative trans-oesophageal echocardiography yields better outcomes in surgical repair of CHD.

    PubMed

    Madriago, Erin J; Punn, Rajesh; Geeter, Natalie; Silverman, Norman H

    2016-02-01

    Trans-oesophageal echocardiographic imaging is valuable in the pre- and post-operative evaluation of children and adults with CHD; however, the frequency by which trans-oesophageal echocardiography guides the intra-operative course of patients is unknown. We retrospectively reviewed 1748 intra-operative trans-oesophageal echocardiograms performed between 1 October, 2005 and 31 December, 2010, and found 99 cases (5.7%) that required return to bypass, based in part upon the intra-operative echocardiographic findings. The diagnoses most commonly requiring further repair and subsequent imaging were mitral valve disease (20.9%), tricuspid valve disease (16.0%), atrioventricular canal defects (12.0%), and pulmonary valve disease (14.1%). The vast majority of those requiring immediate return to bypass benefited by avoiding subsequent operations and longer lengths of hospital stay. A total of 14 patients (0.8%) who received routine imaging required further surgical repair within 1 week, usually due to disease that developed over ensuing days. Patients who had second post-operative trans-oesophageal echocardiograms in the operating room rarely required re-operations, confirming the benefit of routine intra-operative imaging. This study represents a large single institutional review of intra-operative trans-oesophageal echocardiography, and confirms its applicability in the surgical repair of patients with CHD. Routine imaging accurately identifies patients requiring further intervention, does not confer additional risk of mortality or prolonged length of hospital stay, and prevents subsequent operations and associated sequelae in a substantial subset of patients. This study demonstrates the utility of echocardiography in intra-operative monitoring of surgical repair and highlights patients who are most likely to require return to bypass, as well as the co-morbidities of such manipulations.

  15. Clinics in diagnostic imaging (169). Intermuscular lipoma in the thenar eminence of the right hand.

    PubMed

    Venkatesh, Sandeep Halagatti; Wong, Bak Siew Steven

    2016-08-01

    A 54-year-old woman presented with a large mass on her right hand that was progressively enlarging over a period of a few years. She had cosmetic concerns about the enlarging mass and experienced interference with routine activity. Physical examination revealed a soft, mobile, non-tender, lobulated mass with well-defined margins. Magnetic resonance imaging showed the soft lump to be a lipomatous mass in the deep palmar space of the hand, which was subsequently surgically resected. The imaging features of deep palmar lipomas of the hand and other common benign lesions at this location are discussed. Copyright: © Singapore Medical Association.

  16. Establishing Quantitative Within-Subject Confidence Limits For Clinical Stereoroentgenographs

    NASA Astrophysics Data System (ADS)

    Korn, Edward L.; Baumrind, Sheldon; Chafetz, Neil; Curry, Sean; Moffitt, Francis

    1983-07-01

    It is now quite clear that under ideal conditions, discrete points can be located on x-ray films with standard deviations of less than 50 i. However, under routine clinical conditions, such considerations as individual variation in anatomy, movement of the subject between exposures, and variations in image quality combine to produce considerable reductions in the confidence which can be placed in quantitative assessments made from stereoroentgenographic films. This paper discusses some considerations involved in designing mathematical models in such a way as to optimize the use of imperfect data in answering specific clinical questions.

  17. PACS in the Utrecht University Hospital: final conclusions of the clinical evaluation

    NASA Astrophysics Data System (ADS)

    Wilmink, J. B.; ter Haar Romeny, Bart M.; Barneveld Binkhuysen, Frits H.; Achterberg, A. J.; Zuiderveld, Karel J.; Calkoen, P.; Kouwenberg, Jef M.

    1990-08-01

    In the past three years, a clinical evaluation of a PACS has been performed in the Utrecht University Hospital as part of the Dutch PACS project. The clinical evaluation focussed on the following aspects: technical evaluation of the prototype PACS equipment coupled to the HIS; diagnostic accuracy studies; studies concerning the impact on the organization of the radiology-department and the referring wards; and cost-savings analysis. Some of the results of these subprojects have already been presented at previous SPIE conferences. In this paper the general condusions are presented about the usefulness of the evaluated PAC-System in the daily routine of radiology department and clinic. By making available the images of radiological examinations fast, complete, reliable and continously on the ward, concrete improvements with regard to the current process could be realized. The possibilities of PACS caused an increasing enthousiasm among the clinicians. By the easier access to all images of their patients during 24 hours/day, they saw more images on the day of the examination and images could be more easily used at consultations of other specialists. The overall conclusion is positive, but a lot of work has to be done to transform PACS from an experimental setup into a routine production system on which a flimless hospital can be based. A complete PACS needs an inteffigent Image Management System, which indudes prefetching algorithms based on data from the Hospital Information System and automated procedures for removing obsolete images from the local buffers in the workstations. As yet PACS is very expensive, and the direct savings in the hospital cannot compensate for the high costs of investment. Possibly PACS can contribute to a shorter stay of patients in the hospital. This will lead to savings for government and health insurance companies and they can be expected to contribute to PAS implementation studies.

  18. Markerless motion estimation for motion-compensated clinical brain imaging

    NASA Astrophysics Data System (ADS)

    Kyme, Andre Z.; Se, Stephen; Meikle, Steven R.; Fulton, Roger R.

    2018-05-01

    Motion-compensated brain imaging can dramatically reduce the artifacts and quantitative degradation associated with voluntary and involuntary subject head motion during positron emission tomography (PET), single photon emission computed tomography (SPECT) and computed tomography (CT). However, motion-compensated imaging protocols are not in widespread clinical use for these modalities. A key reason for this seems to be the lack of a practical motion tracking technology that allows for smooth and reliable integration of motion-compensated imaging protocols in the clinical setting. We seek to address this problem by investigating the feasibility of a highly versatile optical motion tracking method for PET, SPECT and CT geometries. The method requires no attached markers, relying exclusively on the detection and matching of distinctive facial features. We studied the accuracy of this method in 16 volunteers in a mock imaging scenario by comparing the estimated motion with an accurate marker-based method used in applications such as image guided surgery. A range of techniques to optimize performance of the method were also studied. Our results show that the markerless motion tracking method is highly accurate (<2 mm discrepancy against a benchmarking system) on an ethnically diverse range of subjects and, moreover, exhibits lower jitter and estimation of motion over a greater range than some marker-based methods. Our optimization tests indicate that the basic pose estimation algorithm is very robust but generally benefits from rudimentary background masking. Further marginal gains in accuracy can be achieved by accounting for non-rigid motion of features. Efficiency gains can be achieved by capping the number of features used for pose estimation provided that these features adequately sample the range of head motion encountered in the study. These proof-of-principle data suggest that markerless motion tracking is amenable to motion-compensated brain imaging and holds

  19. CLINICAL AUDIT OF IMAGE QUALITY IN RADIOLOGY USING VISUAL GRADING CHARACTERISTICS ANALYSIS.

    PubMed

    Tesselaar, Erik; Dahlström, Nils; Sandborg, Michael

    2016-06-01

    The aim of this work was to assess whether an audit of clinical image quality could be efficiently implemented within a limited time frame using visual grading characteristics (VGC) analysis. Lumbar spine radiography, bedside chest radiography and abdominal CT were selected. For each examination, images were acquired or reconstructed in two ways. Twenty images per examination were assessed by 40 radiology residents using visual grading of image criteria. The results were analysed using VGC. Inter-observer reliability was assessed. The results of the visual grading analysis were consistent with expected outcomes. The inter-observer reliability was moderate to good and correlated with perceived image quality (r(2) = 0.47). The median observation time per image or image series was within 2 min. These results suggest that the use of visual grading of image criteria to assess the quality of radiographs provides a rapid method for performing an image quality audit in a clinical environment. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. An open architecture for medical image workstation

    NASA Astrophysics Data System (ADS)

    Liang, Liang; Hu, Zhiqiang; Wang, Xiangyun

    2005-04-01

    Dealing with the difficulties of integrating various medical image viewing and processing technologies with a variety of clinical and departmental information systems and, in the meantime, overcoming the performance constraints in transferring and processing large-scale and ever-increasing image data in healthcare enterprise, we design and implement a flexible, usable and high-performance architecture for medical image workstations. This architecture is not developed for radiology only, but for any workstations in any application environments that may need medical image retrieving, viewing, and post-processing. This architecture contains an infrastructure named Memory PACS and different kinds of image applications built on it. The Memory PACS is in charge of image data caching, pre-fetching and management. It provides image applications with a high speed image data access and a very reliable DICOM network I/O. In dealing with the image applications, we use dynamic component technology to separate the performance-constrained modules from the flexibility-constrained modules so that different image viewing or processing technologies can be developed and maintained independently. We also develop a weakly coupled collaboration service, through which these image applications can communicate with each other or with third party applications. We applied this architecture in developing our product line and it works well. In our clinical sites, this architecture is applied not only in Radiology Department, but also in Ultrasonic, Surgery, Clinics, and Consultation Center. Giving that each concerned department has its particular requirements and business routines along with the facts that they all have different image processing technologies and image display devices, our workstations are still able to maintain high performance and high usability.

  1. Moxifloxacin: Clinically compatible contrast agent for multiphoton imaging

    NASA Astrophysics Data System (ADS)

    Wang, Taejun; Jang, Won Hyuk; Lee, Seunghun; Yoon, Calvin J.; Lee, Jun Ho; Kim, Bumju; Hwang, Sekyu; Hong, Chun-Pyo; Yoon, Yeoreum; Lee, Gilgu; Le, Viet-Hoan; Bok, Seoyeon; Ahn, G.-One; Lee, Jaewook; Gho, Yong Song; Chung, Euiheon; Kim, Sungjee; Jang, Myoung Ho; Myung, Seung-Jae; Kim, Myoung Joon; So, Peter T. C.; Kim, Ki Hean

    2016-06-01

    Multiphoton microscopy (MPM) is a nonlinear fluorescence microscopic technique widely used for cellular imaging of thick tissues and live animals in biological studies. However, MPM application to human tissues is limited by weak endogenous fluorescence in tissue and cytotoxicity of exogenous probes. Herein, we describe the applications of moxifloxacin, an FDA-approved antibiotic, as a cell-labeling agent for MPM. Moxifloxacin has bright intrinsic multiphoton fluorescence, good tissue penetration and high intracellular concentration. MPM with moxifloxacin was demonstrated in various cell lines, and animal tissues of cornea, skin, small intestine and bladder. Clinical application is promising since imaging based on moxifloxacin labeling could be 10 times faster than imaging based on endogenous fluorescence.

  2. Multispectral, Fluorescent and Photoplethysmographic Imaging for Remote Skin Assessment

    PubMed Central

    Spigulis, Janis

    2017-01-01

    Optical tissue imaging has several advantages over the routine clinical imaging methods, including non-invasiveness (it does not change the structure of tissues), remote operation (it avoids infections) and the ability to quantify the tissue condition by means of specific image parameters. Dermatologists and other skin experts need compact (preferably pocket-size), self-sustaining and easy-to-use imaging devices. The operational principles and designs of ten portable in-vivo skin imaging prototypes developed at the Biophotonics Laboratory of Institute of Atomic Physics and Spectroscopy, University of Latvia during the recent five years are presented in this paper. Four groups of imaging devices are considered. Multi-spectral imagers offer possibilities for distant mapping of specific skin parameters, thus facilitating better diagnostics of skin malformations. Autofluorescence intensity and photobleaching rate imagers show a promising potential for skin tumor identification and margin delineation. Photoplethysmography video-imagers ensure remote detection of cutaneous blood pulsations and can provide real-time information on cardiovascular parameters and anesthesia efficiency. Multimodal skin imagers perform several of the abovementioned functions by taking a number of spectral and video images with the same image sensor. Design details of the developed prototypes and results of clinical tests illustrating their functionality are presented and discussed. PMID:28534815

  3. NIRS in clinical neurology - a 'promising' tool?

    PubMed

    Obrig, Hellmuth

    2014-01-15

    Near-infrared spectroscopy (NIRS) has become a relevant research tool in neuroscience. In special populations such as infants and for special tasks such as walking, NIRS has asserted itself as a low resolution functional imaging technique which profits from its ease of application, portability and the option to co-register other neurophysiological and behavioral data in a 'near natural' environment. For clinical use in neurology this translates into the option to provide a bed-side oximeter for the brain, broadly available at comparatively low costs. However, while some potential for routine brain monitoring during cardiac and vascular surgery and in neonatology has been established, NIRS is largely unknown to clinical neurologists. The article discusses some of the reasons for this lack of use in clinical neurology. Research using NIRS in three major neurologic diseases (cerebrovascular disease, epilepsy and headache) is reviewed. Additionally the potential to exploit the established position of NIRS as a functional imaging tool with regard to clinical questions such as preoperative functional assessment and neurorehabilitation is discussed. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Predictors and variation of routine home discharge in critically ill adults with cystic fibrosis.

    PubMed

    Oud, Lavi; Chan, Yiu Ming

    2018-06-01

    The short-term outcomes of patients with cystic fibrosis (CF) surviving critical illness were not examined systematically. To determine the factors associated with and variation in rates of routine home discharge among ICU-managed adult CF patients. Predictors of routine home discharge and its hospital-level variation were examined in ICU-managed adults with cystic fibrosis in Texas during 2004-2013. Older age, rural residence, and severity of illness decreased odds of routine home discharge, while hospitalization in facilities accredited as part of the Cystic Fibrosis Foundation Care Center Network nearly doubled the odds of routine home discharge. The median (interquartile) adjusted rate of routine home discharge was 62.0% (31.5-82.5). The identified determinants of routine home discharge can inform clinical decision-making, while the demonstrated wide variation in adjusted across-hospital rates of routine home discharge of ICU-managed adults with CF can provide benchmark data for future quality improvement efforts. Published by Elsevier Inc.

  5. Clinical indicators for recurrent cardiovascular events in acute coronary syndrome patients treated with statins under routine practice in Thailand: an observational study.

    PubMed

    Chinwong, Dujrudee; Patumanond, Jayanton; Chinwong, Surarong; Siriwattana, Khanchai; Gunaparn, Siriluck; Hall, John Joseph; Phrommintikul, Arintaya

    2015-06-16

    Acute coronary syndrome (ACS) patients are at very high cardiovascular risk and tend to have recurrent cardiovascular events. The clinical indicators for subsequent cardiovascular events are limited and need further investigation. This study aimed to explore clinical indicators that were associated with recurrent cardiovascular events following index hospitalization. The data of patients hospitalized with ACS at a tertiary care hospital in northern Thailand between January 2009 and December 2012 were retrospectively reviewed from medical charts and the electronic hospital database. The patients were classified into three groups based on the frequency of recurrent cardiovascular events (nonfatal ACS, nonfatal stroke, or all-cause death) they suffered: no recurrent events (0), single recurrent event (1), and multiple recurrent events (≥2). Ordinal logistic regression was performed to explore the clinical indicators for recurrent cardiovascular events. A total of 405 patients were included; 60 % were male; the average age was 64.9 ± 11.5 years; 40 % underwent coronary revascularization during admission. Overall, 359 (88.6 %) had no recurrent events, 36 (8.9 %) had a single recurrent event, and 10 (2.5 %) had multiple recurrent events. The significant clinical indicators associated with recurrent cardiovascular events were achieving an LDL-C goal of < 70 mg/dL (Adjusted OR = 0.43; 95 % CI = 0.27-0.69, p-value < 0.001), undergoing revascularization during admission (Adjusted OR = 0.44; 95 % CI = 0.24-0.81, p-value = 0.009), being male (Adjusted OR = 1.85; 95 % CI = 1.29-2.66, p-value = 0.001), and decrease estimated glomerular filtration rate (Adjusted OR = 2.46; 95 % CI = 2.21-2.75, p-value < 0.001). The routine clinical practice indicators assessed in ACS patients that were associated with recurrent cardiovascular events were that achieving the LDL-C goal and revascularization are protective factors

  6. Multiscale Integration of -Omic, Imaging, and Clinical Data in Biomedical Informatics

    PubMed Central

    Phan, John H.; Quo, Chang F.; Cheng, Chihwen; Wang, May Dongmei

    2016-01-01

    This paper reviews challenges and opportunities in multiscale data integration for biomedical informatics. Biomedical data can come from different biological origins, data acquisition technologies, and clinical applications. Integrating such data across multiple scales (e.g., molecular, cellular/tissue, and patient) can lead to more informed decisions for personalized, predictive, and preventive medicine. However, data heterogeneity, community standards in data acquisition, and computational complexity are big challenges for such decision making. This review describes genomic and proteomic (i.e., molecular), histopathological imaging (i.e., cellular/tissue), and clinical (i.e., patient) data; it includes case studies for single-scale (e.g., combining genomic or histopathological image data), multiscale (e.g., combining histopathological image and clinical data), and multiscale and multiplatform (e.g., the Human Protein Atlas and The Cancer Genome Atlas) data integration. Numerous opportunities exist in biomedical informatics research focusing on integration of multiscale and multiplatform data. PMID:23231990

  7. Multiscale integration of -omic, imaging, and clinical data in biomedical informatics.

    PubMed

    Phan, John H; Quo, Chang F; Cheng, Chihwen; Wang, May Dongmei

    2012-01-01

    This paper reviews challenges and opportunities in multiscale data integration for biomedical informatics. Biomedical data can come from different biological origins, data acquisition technologies, and clinical applications. Integrating such data across multiple scales (e.g., molecular, cellular/tissue, and patient) can lead to more informed decisions for personalized, predictive, and preventive medicine. However, data heterogeneity, community standards in data acquisition, and computational complexity are big challenges for such decision making. This review describes genomic and proteomic (i.e., molecular), histopathological imaging (i.e., cellular/tissue), and clinical (i.e., patient) data; it includes case studies for single-scale (e.g., combining genomic or histopathological image data), multiscale (e.g., combining histopathological image and clinical data), and multiscale and multiplatform (e.g., the Human Protein Atlas and The Cancer Genome Atlas) data integration. Numerous opportunities exist in biomedical informatics research focusing on integration of multiscale and multiplatform data.

  8. In Vivo Imaging and Monitoring of Transplanted Stem Cells: Clinical Applications

    PubMed Central

    Rodriguez-Porcel, Martin

    2010-01-01

    Regenerative medicine using stem cells has appeared as a potential therapeutic alternative for coronary artery disease, and stem cell clinical studies are currently on their way. However, initial results of these studies have provided mixed information, in part because of the inability to correlate organ functional information with the presence/absence of transplanted stem cells. Recent advances in molecular biology and imaging have allowed the successful noninvasive monitoring of transplanted stem cells in the living subject. In this article, different imaging strategies (direct labeling, indirect labeling with reporter genes) to study the viability and biology of stem cells are discussed. In addition, the limitations of each approach and imaging modality (eg, single photon emission computed tomography, positron emission tomography, and MRI) and their requirements for clinical use are addressed. Use of these strategies will be critical as the different regenerative therapies are being tested for clinical use. PMID:20425184

  9. Clinical and Imaging Heterogeneity of Polymicrogyria: A Study of 328 Patients

    ERIC Educational Resources Information Center

    Leventer, Richard J.; Jansen, Anna; Pilz, Daniela T.; Stoodley, Neil; Marini, Carla; Dubeau, Francois; Malone, Jodie; Mitchell, L. Anne; Mandelstam, Simone; Scheffer, Ingrid E.; Berkovic, Samuel F.; Andermann, Frederick; Andermann, Eva; Guerrini, Renzo; Dobyns, William B.

    2010-01-01

    Polymicrogyria is one of the most common malformations of cortical development and is associated with a variety of clinical sequelae including epilepsy, intellectual disability, motor dysfunction and speech disturbance. It has heterogeneous clinical manifestations and imaging patterns, yet large cohort data defining the clinical and imaging…

  10. Bioimpedance imaging: an overview of potential clinical applications.

    PubMed

    Bayford, Richard; Tizzard, Andrew

    2012-10-21

    Electrical Impedance Tomography (EIT) is an imaging technique based on multiple bio impedance measurements to produce a map (image) of impedance or changes in impedance across a region. Its origins lay in geophysics where it is still used to today. This review highlights potential clinical applications of EIT. Beginning with a brief overview of the underlying principles behind the modality, it describes the background research leading towards the development of the application of EIT for monitoring pulmonary function, detecting and localising tumours and monitoring brain function.

  11. Clinical comparative study with a large-area amorphous silicon flat-panel detector: image quality and visibility of anatomic structures on chest radiography.

    PubMed

    Fink, Christian; Hallscheidt, Peter J; Noeldge, Gerd; Kampschulte, Annette; Radeleff, Boris; Hosch, Waldemar P; Kauffmann, Günter W; Hansmann, Jochen

    2002-02-01

    The objective of this study was to compare clinical chest radiographs of a large-area, flat-panel digital radiography system and a conventional film-screen radiography system. The comparison was based on an observer preference study of image quality and visibility of anatomic structures. Routine follow-up chest radiographs were obtained from 100 consecutive oncology patients using a large-area, amorphous silicon flat-panel detector digital radiography system (dose equivalent to a 400-speed film system). Hard-copy images were compared with previous examinations of the same individuals taken on a conventional film-screen system (200-speed). Patients were excluded if changes in the chest anatomy were detected or if the time interval between the examinations exceeded 1 year. Observer preference was evaluated for the image quality and the visibility of 15 anatomic structures using a five-point scale. Dose measurements with a chest phantom showed a dose reduction of approximately 50% with the digital radiography system compared with the film-screen radiography system. The image quality and the visibility of all but one anatomic structure of the images obtained with the digital flat-panel detector system were rated significantly superior (p < or = 0.0003) to those obtained with the conventional film-screen radiography system. The image quality and visibility of anatomic structures on the images obtained by the flat-panel detector system were perceived as equal or superior to the images from conventional film-screen chest radiography. This was true even though the radiation dose was reduced approximately 50% with the digital flat-panel detector system.

  12. NCI Workshop Report: Clinical and Computational Requirements for Correlating Imaging Phenotypes with Genomics Signatures.

    PubMed

    Colen, Rivka; Foster, Ian; Gatenby, Robert; Giger, Mary Ellen; Gillies, Robert; Gutman, David; Heller, Matthew; Jain, Rajan; Madabhushi, Anant; Madhavan, Subha; Napel, Sandy; Rao, Arvind; Saltz, Joel; Tatum, James; Verhaak, Roeland; Whitman, Gary

    2014-10-01

    The National Cancer Institute (NCI) Cancer Imaging Program organized two related workshops on June 26-27, 2013, entitled "Correlating Imaging Phenotypes with Genomics Signatures Research" and "Scalable Computational Resources as Required for Imaging-Genomics Decision Support Systems." The first workshop focused on clinical and scientific requirements, exploring our knowledge of phenotypic characteristics of cancer biological properties to determine whether the field is sufficiently advanced to correlate with imaging phenotypes that underpin genomics and clinical outcomes, and exploring new scientific methods to extract phenotypic features from medical images and relate them to genomics analyses. The second workshop focused on computational methods that explore informatics and computational requirements to extract phenotypic features from medical images and relate them to genomics analyses and improve the accessibility and speed of dissemination of existing NIH resources. These workshops linked clinical and scientific requirements of currently known phenotypic and genotypic cancer biology characteristics with imaging phenotypes that underpin genomics and clinical outcomes. The group generated a set of recommendations to NCI leadership and the research community that encourage and support development of the emerging radiogenomics research field to address short-and longer-term goals in cancer research.

  13. NPS assessment of color medical image displays using a monochromatic CCD camera

    NASA Astrophysics Data System (ADS)

    Roehrig, Hans; Gu, Xiliang; Fan, Jiahua

    2012-10-01

    This paper presents an approach to Noise Power Spectrum (NPS) assessment of color medical displays without using an expensive imaging colorimeter. The R, G and B color uniform patterns were shown on the display under study and the images were taken using a high resolution monochromatic camera. A colorimeter was used to calibrate the camera images. Synthetic intensity images were formed by the weighted sum of the R, G, B and the dark screen images. Finally the NPS analysis was conducted on the synthetic images. The proposed method replaces an expensive imaging colorimeter for NPS evaluation, which also suggests a potential solution for routine color medical display QA/QC in the clinical area, especially when imaging of display devices is desired

  14. Development and Evaluation of Reference Standards for Image-based Telemedicine Diagnosis and Clinical Research Studies in Ophthalmology

    PubMed Central

    Ryan, Michael C.; Ostmo, Susan; Jonas, Karyn; Berrocal, Audina; Drenser, Kimberly; Horowitz, Jason; Lee, Thomas C.; Simmons, Charles; Martinez-Castellanos, Maria-Ana; Chan, R.V. Paul; Chiang, Michael F.

    2014-01-01

    Information systems managing image-based data for telemedicine or clinical research applications require a reference standard representing the correct diagnosis. Accurate reference standards are difficult to establish because of imperfect agreement among physicians, and discrepancies between clinical vs. image-based diagnosis. This study is designed to describe the development and evaluation of reference standards for image-based diagnosis, which combine diagnostic impressions of multiple image readers with the actual clinical diagnoses. We show that agreement between image reading and clinical examinations was imperfect (689 [32%] discrepancies in 2148 image readings), as was inter-reader agreement (kappa 0.490-0.652). This was improved by establishing an image-based reference standard defined as the majority diagnosis given by three readers (13% discrepancies with image readers). It was further improved by establishing an overall reference standard that incorporated the clinical diagnosis (10% discrepancies with image readers). These principles of establishing reference standards may be applied to improve robustness of real-world systems supporting image-based diagnosis. PMID:25954463

  15. Clinical imaging guidelines part 4: challenges in identifying, engaging and collaborating with stakeholders.

    PubMed

    Bettmann, Michael A; Oikarinen, Helja; Rehani, Madan; Holmberg, Ola; del Rosario Perez, Maria; Naidoo, Anusha; Do, Kyung-Hyun; Dreyer, Keith; Ebdon-Jackson, Steve

    2015-04-01

    The effective development and use of clinical imaging guidelines requires an understanding of who the stakeholders are, what their interests in the process are, and what roles they should play. If the appropriate stakeholders are not engaged in the right roles, it is unlikely that clinical imaging guidelines will be successfully developed, relied on, and actually used. Some stakeholders are obvious: for the development of clinical imaging guidelines, both imagers and those who request examinations, such as general practitioners, internists, and medical specialists, must be involved. To gain acceptance, other relevant groups are stakeholders, including medical societies, other health care professionals, insurers, health IT experts and vendors, and patients. The role of stakeholders must be dictated by their specific interest. For some, involvement in the creation of guidelines is the right role. For others, such as regulators or insurers, reviews or invitations to comment are required, and for others, such as medical educators, it is probably sufficient to provide information and create awareness. Only through a careful consideration of who the stakeholders are and what are their interests are the successful development, acceptance, and use of clinical imaging guidelines likely to occur. Future efforts must focus on collaboration, particularly among groups that create clinical imaging guidelines and those that can support their use, and on regulatory roles and mandates. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  16. Quantitative evaluation of high intensity signal on MIP images of carotid atherosclerotic plaques from routine TOF-MRA reveals elevated volumes of intraplaque hemorrhage and lipid rich necrotic core.

    PubMed

    Yamada, Kiyofumi; Song, Yan; Hippe, Daniel S; Sun, Jie; Dong, Li; Xu, Dongxiang; Ferguson, Marina S; Chu, Baocheng; Hatsukami, Thomas S; Chen, Min; Zhou, Cheng; Yuan, Chun

    2012-11-29

    Carotid intraplaque hemorrhage (IPH) and lipid rich necrotic core (LRNC) have been associated with accelerated plaque growth, luminal narrowing, future surface disruption and development of symptomatic events. The aim of this study was to evaluate the quantitative relationships between high intensity signals (HIS) in the plaque on TOF-MRA and IPH or LRNC volumes as measured by multicontrast weighted CMR. Seventy six patients with a suspected carotid artery stenosis or carotid plaque by ultrasonography underwent multicontrast carotid CMR. HIS presence and volume were measured from TOF-MRA MIP images while IPH and LRNC volumes were separately measured from multicontrast CMR. For detecting IPH, HIS on MIP images overall had high specificity (100.0%, 95% CI: 93.0 - 100.0%) but relatively low sensitivity (32%, 95% CI: 20.8 - 47.9%). However, the sensitivity had a significant increasing relationship with underlying IPH volume (p = 0.033) and degree of stenosis (p = 0.022). Mean IPH volume was 2.7 times larger in those with presence of HIS than in those without (142.8 ± 97.7 mm(3) vs. 53.4 ± 56.3 mm(3), p = 0.014). Similarly, mean LRNC volume was 3.4 times larger in those with HIS present (379.8 ± 203.4 mm(3) vs. 111.3 ± 122.7 mm(3), p = 0.001). There was a strong correlation between the volume of the HIS region and the IPH volume measured from multicontrast CMR (r = 0.96, p < 0.001). MIP images are easily reformatted from three minute, routine, clinical TOF sequences. High intensity signals in carotid plaque on TOF-MRA MIP images are associated with increased intraplaque hemorrhage and lipid-rich necrotic core volumes. The technique is most sensitive in patients with moderate to severe stenosis.

  17. Development and clinical trial of a practical vessel imaging system for vessel punctures in children

    NASA Astrophysics Data System (ADS)

    Cuper, Natasha J.; Verdaasdonk, Rudolf M.; de Roode, Rowland; Septer, Erica

    2008-02-01

    Venipunctures to draw blood for diagnostics can be cumbersome. Multiple puncture attempts are distressing, painful and traumatic, especially for small children. Drawing blood from babies, in particular, is a problem, due to the cutaneous baby fat, tiny veins and, worst case, a pigmented skin. We developed a practical vein viewing system based on IR translumination that, contrary to commercial systems available, has the advantage of: a) low cost, b) easily implemented in routine practice, c) normal and IR image simultaneously available, d) small add-on, e) child friendly IR illuminator and f) efficient IR light coupling. Before introducing the vessel viewer for clinical application in the children's department, parameters were measured in 194 patients (age 0-17 yrs): time to draw blood, number of attempts, skin characteristics, discomfort of patient, and experience of nurse. In this control group, time to draw blood increases significantly with decreasing age of the children. The instant feedback from the nurses has been valuable for the improvements of especially the illumination sources. A clinical trial has been performed in 125 patients (age 0-6 yrs) to prove effectivity of the system in the blood withdrawal procedure. There was a significant decrease from 13% to 2% in failure rate. Also time needed to search for a vein was significantly decreased. A practical and accessible vein viewing system has been developed and is being introduced for clinical application. Although the concept of patient friendliness is already accepted, measurements need to show the effectiveness for particular groups of patients.

  18. Magnetic resonance imaging protocols for examination of the neurocranium at 3 T.

    PubMed

    Schwindt, W; Kugel, H; Bachmann, R; Kloska, S; Allkemper, T; Maintz, D; Pfleiderer, B; Tombach, B; Heindel, W

    2003-09-01

    The increasing availability of high-field (3 T) MR scanners requires adapting and optimizing clinical imaging protocols to exploit the theoretically higher signal-to-noise ratio (SNR) of the higher field strength. Our aim was to establish reliable and stable protocols meeting the clinical demands for imaging the neurocranium at 3 T. Two hundred patients with a broad range of indications received an examination of the neurocranium with an appropriate assortment of imaging techniques at 3 T. Several imaging parameters were optimized. Keeping scan times comparable to those at 1.5 T we increased spatial resolution. Contrast-enhanced and non-enhanced T1-weighted imaging was best applying gradient-echo and inversion recovery (rather than spin-echo) techniques, respectively. For fluid-attenuated inversion recovery (FLAIR) imaging a TE of 120 ms yielded optimum contrast-to-noise ratio (CNR). High-resolution isotropic 3D data sets were acquired within reasonable scan times. Some artifacts were pronounced, but generally imaging profited from the higher SNR. We present a set of optimized examination protocols for neuroimaging at 3 T, which proved to be reliable in a clinical routine setting.

  19. Image acquisition context: procedure description attributes for clinically relevant indexing and selective retrieval of biomedical images.

    PubMed

    Bidgood, W D; Bray, B; Brown, N; Mori, A R; Spackman, K A; Golichowski, A; Jones, R H; Korman, L; Dove, B; Hildebrand, L; Berg, M

    1999-01-01

    To support clinically relevant indexing of biomedical images and image-related information based on the attributes of image acquisition procedures and the judgments (observations) expressed by observers in the process of image interpretation. The authors introduce the notion of "image acquisition context," the set of attributes that describe image acquisition procedures, and present a standards-based strategy for utilizing the attributes of image acquisition context as indexing and retrieval keys for digital image libraries. The authors' indexing strategy is based on an interdependent message/terminology architecture that combines the Digital Imaging and Communication in Medicine (DICOM) standard, the SNOMED (Systematized Nomenclature of Human and Veterinary Medicine) vocabulary, and the SNOMED DICOM microglossary. The SNOMED DICOM microglossary provides context-dependent mapping of terminology to DICOM data elements. The capability of embedding standard coded descriptors in DICOM image headers and image-interpretation reports improves the potential for selective retrieval of image-related information. This favorably affects information management in digital libraries.

  20. [Diagnostic imaging of high-grade astrocytoma: heterogeneity of clinical manifestation, image characteristics, and histopathological findings].

    PubMed

    Okajima, Kaoru; Ohta, Yoshio

    2012-10-01

    Recent developments in diagnostic radiology, which have enabled accurate differential diagnoses of brain tumors, have been well described in the last three decades. MR and PET imaging can also provide information to predict histological grades and prognoses that might influence treatment strategies. However, high-grade astrocytomas consist of many different subtypes that are associated with different imaging and histological characteristics. Hemorrhage and necrosis results in a variety of imaging features, and infiltrative tumor growth entrapping normal neurons may cause different clinical manifestations. We reviewed patients with high-grade astrocytomas that showed various imaging characteristics, with special emphasis on initial symptoms and histological features. Clinicopathological characteristics of astrocytomas were also compared with other malignant tumors. Neurological deficits were not notable in patients with grade 3-4 astrocytomas when they showed infiltrative tumor growth, while brain metastases with compact cellular proliferation caused more neurological symptoms. Infiltrative tumors did not show any enhancing masses on MR imaging, but these tumors may show intratumor heterogeneity. Seizures were reported to be more frequent in low-grade glioma and in secondary glioblastoma. Tumor heterogeneity was also reported in molecular genetic profile, and investigators identified some subsets of astrocytomas. They investigated IHD1/2 mutation, EGFR amplification, TP53 mutation, Ki-67 index, etc. In summary, high-grade astrocytomas are not homogenous groups of tumors, and this is associated with the heterogeneity of clinical manifestation, image characteristics, and histopathological findings. Molecular studies may explain the tumor heterogeneity in the near future.

  1. White Paper AGA: Advanced Imaging in Barrett's Esophagus.

    PubMed

    Sharma, Prateek; Brill, Joel; Canto, Marcia; DeMarco, Daniel; Fennerty, Brian; Gupta, Neil; Laine, Loren; Lieberman, David; Lightdale, Charles; Montgomery, Elizabeth; Odze, Robert; Tokar, Jeffrey; Kochman, Michael

    2015-12-01

    Enhanced imaging technologies such as narrow band imaging, flexible spectral imaging color enhancement, i-Scan, confocal laser endomicroscopy, and optical coherence tomography are readily available for use by endoscopists in routine clinical practice. In November 2014, the American Gastroenterological Association's Center for GI Innovation and Technology conducted a 2-day workshop to discuss endoscopic image enhancement technologies, focusing on their role in 2 specific clinical conditions (colon polyps and Barrett's esophagus) and on issues relating to training and implementation of these technologies (white papers). Although the majority of the studies that use enhanced imaging technologies have been positive, these techniques ideally need to be validated in larger cohorts and in community centers. As it stands today, detailed endoscopic examination with high-definition white-light endoscopy and random 4-quadrant biopsy remains the standard of care. However, the workshop panelists agreed that in the hands of endoscopists who have met the preservation and incorporation of valuable endoscopic innovation thresholds (diagnostic accuracy) with enhanced imaging techniques (specific technologies), use of the technique in Barrett's esophagus patients is appropriate. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.

  2. The Use of Routine Postoperative Microscopy and Culture Screening Following Elective Hip and Knee Arthroplasty: An Unnecessary Cost With No Effect on Clinical Management?

    PubMed

    Kemp, Mark A; Martina, Ka; Collins, Claire L; Salmon, Lucy J; Gooden, Benjamin R; Lyons, Matthew C

    2017-04-01

    The use of microscopy and culture screening to detect pathogenic microorganisms followed by a decolonization protocol is a widely performed practice prior to elective hip and knee arthroplasty. In our center, the routine care of hip and knee arthroplasty also involves postoperative screening including direct culture of the surgical site. The aim of this study was to assess the frequency of pathogen detection following these tests and to determine whether routine postoperative screening, with particular reference to postoperative surgical site culture, led to any change in clinical management of these patients. A series of 1000 patients undergoing hip or knee arthroplasty at The Mater Hospital between January 2014 and December 2015 were identified from our arthroplasty database. Results of preoperative and postoperative microscopy and culture screening were reviewed by 2 independent researchers. Of the 1000 subjects, positive microscopy and culture results were identified in 88 patients (8.8%) preoperatively and 5 patients (0.5%) postoperatively. None of the 1000 postoperative surgical site swabs had a positive microscopy and culture screen. All the 5 positive postoperative microscopy and culture screen results were in patients who had positive cultures preoperatively. There were no positive postoperative microscopy and culture screen results in patients who had had negative preoperative results. Postoperative screening was performed at a cost of AUS$213 per patient. Routine postoperative surgical site culture following hip and knee arthroplasty does not alter clinical management, has a significant associated financial cost, and has the potential to expose the patient to a risk of surgical site infection and is therefore not supported. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Comprehensive evaluation of an image segmentation technique for measuring tumor volume from CT images

    NASA Astrophysics Data System (ADS)

    Deng, Xiang; Huang, Haibin; Zhu, Lei; Du, Guangwei; Xu, Xiaodong; Sun, Yiyong; Xu, Chenyang; Jolly, Marie-Pierre; Chen, Jiuhong; Xiao, Jie; Merges, Reto; Suehling, Michael; Rinck, Daniel; Song, Lan; Jin, Zhengyu; Jiang, Zhaoxia; Wu, Bin; Wang, Xiaohong; Zhang, Shuai; Peng, Weijun

    2008-03-01

    Comprehensive quantitative evaluation of tumor segmentation technique on large scale clinical data sets is crucial for routine clinical use of CT based tumor volumetry for cancer diagnosis and treatment response evaluation. In this paper, we present a systematic validation study of a semi-automatic image segmentation technique for measuring tumor volume from CT images. The segmentation algorithm was tested using clinical data of 200 tumors in 107 patients with liver, lung, lymphoma and other types of cancer. The performance was evaluated using both accuracy and reproducibility. The accuracy was assessed using 7 commonly used metrics that can provide complementary information regarding the quality of the segmentation results. The reproducibility was measured by the variation of the volume measurements from 10 independent segmentations. The effect of disease type, lesion size and slice thickness of image data on the accuracy measures were also analyzed. Our results demonstrate that the tumor segmentation algorithm showed good correlation with ground truth for all four lesion types (r = 0.97, 0.99, 0.97, 0.98, p < 0.0001 for liver, lung, lymphoma and other respectively). The segmentation algorithm can produce relatively reproducible volume measurements on all lesion types (coefficient of variation in the range of 10-20%). Our results show that the algorithm is insensitive to lesion size (coefficient of determination close to 0) and slice thickness of image data(p > 0.90). The validation framework used in this study has the potential to facilitate the development of new tumor segmentation algorithms and assist large scale evaluation of segmentation techniques for other clinical applications.

  4. The art and science of using routine outcome measurement in mental health benchmarking.

    PubMed

    McKay, Roderick; Coombs, Tim; Duerden, David

    2014-02-01

    To report and critique the application of routine outcome measurement data when benchmarking Australian mental health services. The experience of the authors as participants and facilitators of benchmarking activities is augmented by a review of the literature regarding mental health benchmarking in Australia. Although the published literature is limited, in practice, routine outcome measures, in particular the Health of the National Outcomes Scales (HoNOS) family of measures, are used in a variety of benchmarking activities. Use in exploring similarities and differences in consumers between services and the outcomes of care are illustrated. This requires the rigour of science in data management and interpretation, supplemented by the art that comes from clinical experience, a desire to reflect on clinical practice and the flexibility to use incomplete data to explore clinical practice. Routine outcome measurement data can be used in a variety of ways to support mental health benchmarking. With the increasing sophistication of information development in mental health, the opportunity to become involved in benchmarking will continue to increase. The techniques used during benchmarking and the insights gathered may prove useful to support reflection on practice by psychiatrists and other senior mental health clinicians.

  5. [3D imaging benefits in clinical pratice of orthodontics].

    PubMed

    Frèrejouand, Emmanuel

    2016-12-01

    3D imaging possibilities raised up in the last few years in the orthodontic field. In 2016, it can be used for diagnosis improvement and treatment planning by using digital set up combined to CBCT. It is relevant for orthodontic mechanic updating by creating visible or invisible customised appliances. It forms the basis of numerous scientific researches. The author explains the progress 3D imaging brings to diagnosis and clinics but also highlights the requirements it creates. The daily use of these processes in orthodontic clinical practices needs to be regulated regarding the benefit/risk ratio and the patient satisfaction. The command of the digital work flow created by these technics requires habits modifications from the orthodontist and his staff. © EDP Sciences, SFODF, 2016.

  6. Clinical review: Lung imaging in acute respiratory distress syndrome patients - an update

    PubMed Central

    2013-01-01

    Over the past 30 years lung imaging has greatly contributed to the current understanding of the pathophysiology and the management of acute respiratory distress syndrome (ARDS). In the past few years, in addition to chest X-ray and lung computed tomography, newer functional lung imaging techniques, such as lung ultrasound, positron emission tomography, electrical impedance tomography and magnetic resonance, have been gaining a role as diagnostic tools to optimize lung assessment and ventilator management in ARDS patients. Here we provide an updated clinical review of lung imaging in ARDS over the past few years to offer an overview of the literature on the available imaging techniques from a clinical perspective. PMID:24238477

  7. Design and implementation of a controlled clinical trial to evaluate the effectiveness and efficiency of routine opt-out rapid human immunodeficiency virus screening in the emergency department.

    PubMed

    Haukoos, Jason S; Hopkins, Emily; Byyny, Richard L; Conroy, Amy A; Silverman, Morgan; Eisert, Sheri; Thrun, Mark; Wilson, Michael; Boyett, Brian; Heffelfinger, James D

    2009-08-01

    In 2006, the Centers for Disease Control and Prevention (CDC) released revised recommendations for performing human immunodeficiency virus (HIV) testing in health care settings, including implementing routine rapid HIV screening, the use of an integrated opt-out consent, and limited prevention counseling. Emergency departments (EDs) have been a primary focus of these efforts. These revised CDC recommendations were primarily based on feasibility studies and have not been evaluated through the application of rigorous research methods. This article describes the design and implementation of a large prospective controlled clinical trial to evaluate the CDC's recommendations in an ED setting. From April 15, 2007, through April 15, 2009, a prospective quasi-experimental equivalent time-samples clinical trial was performed to compare the clinical effectiveness and efficiency of routine (nontargeted) opt-out rapid HIV screening (intervention) to physician-directed diagnostic rapid HIV testing (control) in a high-volume urban ED. In addition, three nested observational studies were performed to evaluate the cost-effectiveness and patient and staff acceptance of the two rapid HIV testing methods. This article describes the rationale, methodologies, and study design features of this program evaluation clinical trial. It also provides details regarding the integration of the principal clinical trial and its nested observational studies. Such ED-based trials are rare, but serve to provide valid comparisons between testing approaches. Investigators should consider similar methodology when performing future ED-based health services research.

  8. [Clinical use of interventional MR imaging].

    PubMed

    Kahn, Thomas; Schulz, Thomas; Moche, Michael; Prothmann, Sascha; Schneider, Jens-Peter

    2003-01-01

    The integration of diagnostic and therapeutic procedures by MRI is based on the combination of excellent morphologic and functional imaging. The spectrum of MR-guided interventions includes biopsies, thermal ablation procedures, vascular applications, and intraoperative MRI. In all these applications, different scientific groups have obtained convincing results in basic developments as well as in clinical use. Interventional MRI (iMRI) is expected to attain an important role in interventional radiology, minimal invasive therapy, and monitoring of surgical procedures.

  9. What is the role of imaging in the clinical diagnosis of osteoarthritis and disease management?

    PubMed

    Wang, Xia; Oo, Win Min; Linklater, James M

    2018-05-01

    While OA is predominantly diagnosed on the basis of clinical criteria, imaging may aid with differential diagnosis in clinically suspected cases. While plain radiographs are traditionally the first choice of imaging modality, MRI and US also have a valuable role in assessing multiple pathologic features of OA, although each has particular advantages and disadvantages. Although modern imaging modalities provide the capability to detect a wide range of osseous and soft tissue (cartilage, menisci, ligaments, synovitis, effusion) OA-related structural damage, this extra information has not yet favourably influenced the clinical decision-making and management process. Imaging is recommended if there are unexpected rapid changes in clinical outcomes to determine whether it relates to disease severity or an additional diagnosis. On developing specific treatments, imaging serves as a sensitive tool to measure treatment response. This narrative review aims to describe the role of imaging modalities to aid in OA diagnosis, disease progression and management. It also provides insight into the use of these modalities in finding targeted treatment strategies in clinical research.

  10. Magnetic nanoparticles for MR imaging: agents, techniques and cardiovascular applications

    PubMed Central

    Sosnovik, David E.; Nahrendorf, Matthias; Weissleder, Ralph

    2008-01-01

    Magnetic nanoparticles (MNP) are playing an increasingly important role in cardiovascular molecular imaging. These agents are superparamagnetic and consist of a central core of iron-oxide surrounded by a carbohydrate or polymer coat. The size, physical properties and pharmacokinetics of MNP make them highly suited to cellular and molecular imaging of atherosclerotic plaque and myocardial injury. MNP have a sensitivity in the nanomolar range and can be detected with T1, T2, T2*, off resonance and steady state free precession sequences. Targeted imaging with MNP is being actively explored and can be achieved through either surface modification or through the attachment of an affinity ligand to the nanoparticle. First generation MNP are already in clinical use and second generation agents, with longer blood half lives, are likely to be approved for routine clinical use in the near future. PMID:18324368

  11. Development and Application of Stable Phantoms for the Evaluation of Photoacoustic Imaging Instruments

    PubMed Central

    Bohndiek, Sarah E.; Bodapati, Sandhya; Van De Sompel, Dominique; Kothapalli, Sri-Rajasekhar; Gambhir, Sanjiv S.

    2013-01-01

    Photoacoustic imaging combines the high contrast of optical imaging with the spatial resolution and penetration depth of ultrasound. This technique holds tremendous potential for imaging in small animals and importantly, is clinically translatable. At present, there is no accepted standard physical phantom that can be used to provide routine quality control and performance evaluation of photoacoustic imaging instruments. With the growing popularity of the technique and the advent of several commercial small animal imaging systems, it is important to develop a strategy for assessment of such instruments. Here, we developed a protocol for fabrication of physical phantoms for photoacoustic imaging from polyvinyl chloride plastisol (PVCP). Using this material, we designed and constructed a range of phantoms by tuning the optical properties of the background matrix and embedding spherical absorbing targets of the same material at different depths. We created specific designs to enable: routine quality control; the testing of robustness of photoacoustic signals as a function of background; and the evaluation of the maximum imaging depth available. Furthermore, we demonstrated that we could, for the first time, evaluate two small animal photoacoustic imaging systems with distinctly different light delivery, ultrasound imaging geometries and center frequencies, using stable physical phantoms and directly compare the results from both systems. PMID:24086557

  12. Real-time clinically oriented array-based in vivo combined photoacoustic and power Doppler imaging

    NASA Astrophysics Data System (ADS)

    Harrison, Tyler; Jeffery, Dean; Wiebe, Edward; Zemp, Roger J.

    2014-03-01

    Photoacoustic imaging has great potential for identifying vascular regions for clinical imaging. In addition to assessing angiogenesis in cancers, there are many other disease processes that result in increased vascularity that present novel targets for photoacoustic imaging. Doppler imaging can provide good localization of large vessels, but poor imaging of small or low flow speed vessels and is susceptible to motion artifacts. Photoacoustic imaging can provide visualization of small vessels, but due to the filtering effects of ultrasound transducers, only shows the edges of large vessels. Thus, we have combined photoacoustic imaging with ultrasound power Doppler to provide contrast agent- free vascular imaging. We use a research-oriented ultrasound array system to provide interlaced ultrasound, Doppler, and photoacoustic imaging. This system features realtime display of all three modalities with adjustable persistence, rejection, and compression. For ease of use in a clinical setting, display of each mode can be disabled. We verify the ability of this system to identify vessels with varying flow speeds using receiver operating characteristic curves, and find that as flow speed falls, photoacoustic imaging becomes a much better method for identifying blood vessels. We also present several in vivo images of the thyroid and several synovial joints to assess the practicality of this imaging for clinical applications.

  13. Can machine-learning improve cardiovascular risk prediction using routine clinical data?

    PubMed Central

    Kai, Joe; Garibaldi, Jonathan M.; Qureshi, Nadeem

    2017-01-01

    Background Current approaches to predict cardiovascular risk fail to identify many people who would benefit from preventive treatment, while others receive unnecessary intervention. Machine-learning offers opportunity to improve accuracy by exploiting complex interactions between risk factors. We assessed whether machine-learning can improve cardiovascular risk prediction. Methods Prospective cohort study using routine clinical data of 378,256 patients from UK family practices, free from cardiovascular disease at outset. Four machine-learning algorithms (random forest, logistic regression, gradient boosting machines, neural networks) were compared to an established algorithm (American College of Cardiology guidelines) to predict first cardiovascular event over 10-years. Predictive accuracy was assessed by area under the ‘receiver operating curve’ (AUC); and sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) to predict 7.5% cardiovascular risk (threshold for initiating statins). Findings 24,970 incident cardiovascular events (6.6%) occurred. Compared to the established risk prediction algorithm (AUC 0.728, 95% CI 0.723–0.735), machine-learning algorithms improved prediction: random forest +1.7% (AUC 0.745, 95% CI 0.739–0.750), logistic regression +3.2% (AUC 0.760, 95% CI 0.755–0.766), gradient boosting +3.3% (AUC 0.761, 95% CI 0.755–0.766), neural networks +3.6% (AUC 0.764, 95% CI 0.759–0.769). The highest achieving (neural networks) algorithm predicted 4,998/7,404 cases (sensitivity 67.5%, PPV 18.4%) and 53,458/75,585 non-cases (specificity 70.7%, NPV 95.7%), correctly predicting 355 (+7.6%) more patients who developed cardiovascular disease compared to the established algorithm. Conclusions Machine-learning significantly improves accuracy of cardiovascular risk prediction, increasing the number of patients identified who could benefit from preventive treatment, while avoiding unnecessary treatment of others

  14. Can machine-learning improve cardiovascular risk prediction using routine clinical data?

    PubMed

    Weng, Stephen F; Reps, Jenna; Kai, Joe; Garibaldi, Jonathan M; Qureshi, Nadeem

    2017-01-01

    Current approaches to predict cardiovascular risk fail to identify many people who would benefit from preventive treatment, while others receive unnecessary intervention. Machine-learning offers opportunity to improve accuracy by exploiting complex interactions between risk factors. We assessed whether machine-learning can improve cardiovascular risk prediction. Prospective cohort study using routine clinical data of 378,256 patients from UK family practices, free from cardiovascular disease at outset. Four machine-learning algorithms (random forest, logistic regression, gradient boosting machines, neural networks) were compared to an established algorithm (American College of Cardiology guidelines) to predict first cardiovascular event over 10-years. Predictive accuracy was assessed by area under the 'receiver operating curve' (AUC); and sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) to predict 7.5% cardiovascular risk (threshold for initiating statins). 24,970 incident cardiovascular events (6.6%) occurred. Compared to the established risk prediction algorithm (AUC 0.728, 95% CI 0.723-0.735), machine-learning algorithms improved prediction: random forest +1.7% (AUC 0.745, 95% CI 0.739-0.750), logistic regression +3.2% (AUC 0.760, 95% CI 0.755-0.766), gradient boosting +3.3% (AUC 0.761, 95% CI 0.755-0.766), neural networks +3.6% (AUC 0.764, 95% CI 0.759-0.769). The highest achieving (neural networks) algorithm predicted 4,998/7,404 cases (sensitivity 67.5%, PPV 18.4%) and 53,458/75,585 non-cases (specificity 70.7%, NPV 95.7%), correctly predicting 355 (+7.6%) more patients who developed cardiovascular disease compared to the established algorithm. Machine-learning significantly improves accuracy of cardiovascular risk prediction, increasing the number of patients identified who could benefit from preventive treatment, while avoiding unnecessary treatment of others.

  15. [COPD routine management in France: are guidelines used in clinical practice?].

    PubMed

    Jebrak, G

    2010-01-01

    COPD management guidelines have been proposed to improve the major outcomes for COPD patients. In clinical practice, COPD treatment is only partially consistent with current guidelines and recommendations. Global initiative for chronic obstructive lung disease (GOLD) guidelines are based on a COPD severity scale and are subject to change as the evidence based evolves. The main purpose of our study was to access whether the treatments prescribed to patients with COPD were consistent with these guidelines. Treatments prescribed by French physicians to 542 patients with COPD in stable conditions were recorded according to the severity of obstruction, using GOLD classification. We compared our prescription data base with the GOLD guidelines. Forty percent of the initial physicians were chest specialists. 78.3 % men, (64.8+/-10.8years) and 25 % were still smokers at inclusion. We found an important discrepancy between recommended treatment and COPD severity. Bronchodilators were commonly prescribed, but 11 % in severe COPD (stages III and IV) did not receive them. Inhaled steroids (ICS) were used respectively in 55.2 %, 59.4 % of patients in stages I, II (FEV1>50 %) (for whom they are not recommended) and 77.4 and 85.3 % in stages III and IV. Only 30 % of patients used ICS+beta2 agonists in the same device. Influenza vaccination had been performed in only half of patients whatever the severity of COPD. Pulmonary rehabilitation had been used by 10 % of patients, (stage II: 6.4 %, stage III: 9.6 %, stage IV: 20.6 %). We confirmed that there are discrepancies between COPD guidelines and routine treatments. Some treatments such as ICS were overused in mild phenotypes, whereas in a high proportion of cases influenza immunisation and rehabilitation were omitted.

  16. Content-based image retrieval from a database of fracture images

    NASA Astrophysics Data System (ADS)

    Müller, Henning; Do Hoang, Phuong Anh; Depeursinge, Adrien; Hoffmeyer, Pierre; Stern, Richard; Lovis, Christian; Geissbuhler, Antoine

    2007-03-01

    This article describes the use of a medical image retrieval system on a database of 16'000 fractures, selected from surgical routine over several years. Image retrieval has been a very active domain of research for several years. It was frequently proposed for the medical domain, but only few running systems were ever tested in clinical routine. For the planning of surgical interventions after fractures, x-ray images play an important role. The fractures are classified according to exact fracture location, plus whether and to which degree the fracture is damaging articulations to see how complicated a reparation will be. Several classification systems for fractures exist and the classification plus the experience of the surgeon lead in the end to the choice of surgical technique (screw, metal plate, ...). This choice is strongly influenced by the experience and knowledge of the surgeons with respect to a certain technique. Goal of this article is to describe a prototype that supplies similar cases to an example to help treatment planning and find the most appropriate technique for a surgical intervention. Our database contains over 16'000 fracture images before and after a surgical intervention. We use an image retrieval system (GNU Image Finding Tool, GIFT) to find cases/images similar to an example case currently under observation. Problems encountered are varying illumination of images as well as strong anatomic differences between patients. Regions of interest are usually small and the retrieval system needs to focus on this region. Results show that GIFT is capable of supplying similar cases, particularly when using relevance feedback, on such a large database. Usual image retrieval is based on a single image as search target but for this application we have to select images by case as similar cases need to be found and not images. A few false positive cases often remain in the results but they can be sorted out quickly by the surgeons. Image retrieval can

  17. Routine intracranial pressure monitoring in acute coma.

    PubMed

    Forsyth, Rob J; Raper, Joseph; Todhunter, Emma

    2015-11-02

    ; range 22 to 44), and all had severe traumatic brain injury, mostly due to traffic incidents. All were receiving care within intensive care units (ICUs) at one of six hospitals in either Bolivia or Ecuador. Investigators followed up 92% of participants for six months or until death. The trial excluded patients with a Glasgow Coma Score (GCS) less than three and fixed dilated pupils on admission on the basis that they had sustained brain injury of an unsalvageable severity.The study compared people managed using either an intracranial monitor or non-invasive monitoring (imaging and clinical examination) to identify potentially harmful raised intracranial pressure. Both study groups used imaging and clinical examination measures.Mortality at six months was 56/144 (39%) in the ICP-monitored group and 67/153 (44%) in the non-invasive group.Unfavourable outcome (defined as death or moderate to severe disability at six months) as assessed by the extended Glasgow Outcome Scale (GOS-E) was 80/144 (56%) in the ICP-monitored group and 93/153 (61%) in the non-invasive group.Six percent of participants in the ICP monitoring group had complications related to the monitoring, none of which met criteria for being a serious adverse event. There were no complications relating to the non-invasive group.Other complications and adverse events were comparable between treatment groups, 70/157 (45%) in the ICP-monitored group and 76/167 (46%) in the non-invasive group.Late mortality in both the monitored and non-invasive groups was high, with 35% of deaths occurring > 14 days after injury. The authors comment that this high late mortality may reflect inadequacies in post-ICU services for disabled survivors requiring specialist rehabilitation care. The data from the single RCT studying the role of routine ICP monitoring in acute traumatic coma fails to provide evidence to support the intervention.Research in this area is complicated by the fact that RCTs necessarily assess the combined impact

  18. Optimization of contrast-enhanced spectral mammography depending on clinical indication.

    PubMed

    Dromain, Clarisse; Canale, Sandra; Saab-Puong, Sylvie; Carton, Ann-Katherine; Muller, Serge; Fallenberg, Eva Maria

    2014-10-01

    The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality.

  19. [Clinical, pathological and imaging features of primary pelvic Ewing's sarcoma].

    PubMed

    Liu, J; Chen, Y; Ling, X L; Gong, Y; Ding, J P; Zhang, Z K; Wang, Y J

    2016-07-19

    To explore the clinical, pathological and imaging features of Ewing's sarcoma in pelvis and to improve knowledge and diagnosis of the disease. A retrospective analysis of the clinical, pathological and imaging data of pathologically confirmed 13 cases of Ewing's sarcoma in pelvis was carried out between May 2008 and March 2016 in the Affiliated Hospital of Hangzhou Normal University, the Third Hospital of Hebei Medical University and the Second Hospital of Hebei Medical University. The median age 13 cases of pelvic primary Ewing's sarcoma was 17 years old.The X-ray and CT imagings showed osteolytic and mixed bone destruction, CT showed mixed type in 10 cases, 8 cases of bone tumors as a flocculent, 10 cases of bone expansion failure, 10 cases of periosteal reaction, the layered 5 cases, radial in 5 cases.Thirteen cases showed soft tissue mass, soft tissue mass was equal or slightly lower density.Four cases showed heterogeneous contrast enhancement.The lesions showed low signal in T1WI and mixed high signal in T2WI of magnetic resonance imaging(MRI). The boundary of the lesions were obscure, and 5 cases had patchy necrosis area, and 9 cases had incomplete false capsule, surrounding soft tissue was violated.Four cases showed heterogeneous contrast enhancement after MRI enhancement scan. The age of onset of Ewing's sarcoma of the pelvis is more concentrated in about 15 years.The imaging feaures are mixed bone destruction and more bone is swelling and permeability damage, soft tissue mass is larger, bone tumor is cloudy or acicular, periosteal reaction in a layered and radial, most cases show that the false envelope is not complete.Combined with clinical and imaging examination, the diagnosis of the disease can be made.

  20. Image quality assessment of a pre-clinical flat-panel volumetric micro-CT scanner

    NASA Astrophysics Data System (ADS)

    Du, Louise Y.; Lee, Ting-Yim; Holdsworth, David W.

    2006-03-01

    Small animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. Current micro-CT systems are capable of achieving spatial resolution on the order of 10 μm, giving highly detailed anatomical information. However, the speed of data acquisition of these systems is relatively slow, when compared with clinical CT systems. Dynamic CT perfusion imaging has proven to be a powerful tool clinically in detecting and diagnosing cancer, stroke, pulmonary and ischemic heart diseases. In order to perform this technique in mice and rats, quantitative CT images must be acquired at a rate of at least 1 Hz. Recently, a research pre-clinical CT scanner (eXplore Ultra, GE Healthcare) has been designed specifically for dynamic perfusion imaging in small animals. Using an amorphous silicon flat-panel detector and a clinical slip-ring gantry, this system is capable of acquiring volumetric image data at a rate of 1 Hz, with in-plane resolution of 150 μm, while covering the entire thoracic region of a mouse or whole organs of a rat. The purpose of this study was to evaluate the principal imaging performance of the micro-CT system, in terms of spatial resolution, image uniformity, linearity, dose and voxel noise for the feasibility of imaging mice and rats. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.7 line pairs per mm and noise of 42 HU, using an acquisition interval of 8 seconds at an entrance dose of 6.4 cGy.