Sample records for state key laboratory

  1. A Dichotomous Key to Tree Cones and Fruits of the Eastern United States.

    ERIC Educational Resources Information Center

    Collins, Linda T.

    1991-01-01

    The author presents a dichotomous key to 29 tree cones, fruits, and nuts of eastern United States. Students can use the key to identify at least 10 species in a 1-hour laboratory assignment. This key uses reproductive structures that are significantly different from others. These structures are durable enough to be used in the laboratory for many…

  2. A comprehensive Laboratory Services Survey of State Public Health Laboratories.

    PubMed

    Inhorn, Stanley L; Wilcke, Burton W; Downes, Frances Pouch; Adjanor, Oluwatosin Omolade; Cada, Ronald; Ford, James R

    2006-01-01

    In November 2004, the Association of Public Health Laboratories (APHL) conducted a Comprehensive Laboratory Services Survey of State Public Health Laboratories (SPHLs) in order to establish the baseline data necessary for Healthy People 2010 Objective 23-13. This objective aims to measure the increase in the proportion of health agencies that provide or assure access to comprehensive laboratory services to support essential public health services. This assessment addressed only SPHLs and served as a baseline to periodically evaluate the level of improvement in the provision of laboratory services over the decade ending 2010. The 2004 survey used selected questions that were identified as key indicators of provision of comprehensive laboratory services. The survey was developed in consultation with the Centers for Disease Control and Prevention National Center for Health Statistics, based on newly developed data sources. Forty-seven states and one territory responded to the survey. The survey was based on the 11 core functions of SPHLs as previously defined by APHL. The range of performance among individual laboratories for the 11 core functions (subobjectives) reflects the challenging issues that have confronted SPHLs in the first half of this decade. APHL is now working on a coordinated effort with other stakeholders to create seamless state and national systems for the provision of laboratory services in support of public health programs. These services are necessary to help face the threats raised by the specter of terrorism, emerging infections, and natural disasters.

  3. The State Public Health Laboratory System.

    PubMed

    Inhorn, Stanley L; Astles, J Rex; Gradus, Stephen; Malmberg, Veronica; Snippes, Paula M; Wilcke, Burton W; White, Vanessa A

    2010-01-01

    This article describes the development since 2000 of the State Public Health Laboratory System in the United States. These state systems collectively are related to several other recent public health laboratory (PHL) initiatives. The first is the Core Functions and Capabilities of State Public Health Laboratories, a white paper that defined the basic responsibilities of the state PHL. Another is the Centers for Disease Control and Prevention National Laboratory System (NLS) initiative, the goal of which is to promote public-private collaboration to assure quality laboratory services and public health surveillance. To enhance the realization of the NLS, the Association of Public Health Laboratories (APHL) launched in 2004 a State Public Health Laboratory System Improvement Program. In the same year, APHL developed a Comprehensive Laboratory Services Survey, a tool to measure improvement through the decade to assure that essential PHL services are provided.

  4. The First United States Microgravity Laboratory

    NASA Technical Reports Server (NTRS)

    Powers, C. Blake (Editor); Shea, Charlotte; Mcmahan, Tracy; Accardi, Denise; Mikatarian, Jeff

    1991-01-01

    The United States Microgravity Laboratory (USML-1) is one part of a science and technology program that will open NASA's next great era of discovery and establish the United States' leadership in space. A key component in the preparation for this new age of exploration, the USML-1 will fly in orbit for extended periods, providing greater opportunities for research in materials science, fluid dynamics, biotechnology, and combustion science. The major components of the USML-1 are the Crystal Growth Furnace, the Surface Tension Driven Convection Experiment (STDCE) Apparatus, and the Drop Physics Module. Other components of USML-1 include Astroculture, Generic Bioprocessing Apparatus, Extended Duration Orbiter Medical Project, Protein Crystal Growth, Space Acceleration Measurement System, Solid Surface Combustion Experiment, Zeolite Crystal Growth and Spacelab Glovebox provided by the European Space Agency.

  5. District, state or regional veterinary diagnostic laboratories.

    PubMed

    Gosser, H S; Morehouse, L G

    1998-08-01

    The district, regional or state laboratory is the local laboratory to which veterinarian practitioners usually submit samples, and consequently these laboratories are usually the first to observe a suspected disease problem. In most countries, these laboratories are under the jurisdiction of the State or region in which they are located. In the United States of America (USA), most veterinary diagnostic laboratories are State-associated and operate under the aegis of either the State Department of Agriculture or a university. The national laboratory provides reference assistance to the State laboratories. In the USA, the national Laboratory (the National Veterinary Services Laboratories) acts as a consultant to confirm difficult diagnoses and administer performance tests for State-associated laboratories. District, state or regional laboratories need to share information regarding technological advances in diagnostic procedures. This need was met in the USA by the formation of the American Association of Veterinary Laboratory Diagnosticians (AAVLD) in the late 1950s. Another requirement of district, state or regional diagnostic laboratories is a method to confirm quality assurance, which was fulfilled in the USA by an accreditation programme established through the AAVLD. The Accreditation Committee evaluates laboratories (on request) in terms of organisation, personnel, physical facilities and equipment, records, finance and budget. Those laboratories which meet the standards as established in the 'Essential Requirements for Accreditation' are given accreditation status, which indicates that they have the expertise and facilities to perform tests on food-producing animals for shipment in national or international commerce and on companion, laboratory or zoo animals. While confidentiality of test records is most important, it is becoming necessary to release certain types of animal disease test information if a country is to participate in the exportation of animals

  6. Secret key distillation from shielded two-qubit states

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bae, Joonwoo

    The quantum states corresponding to a secret key are characterized using the so-called private states, where the key part consisting of a secret key is shielded by the additional systems. Based on the construction, it was shown that a secret key can be distilled from bound entangled states. In this work, I consider the shielded two-qubit states in a key-distillation scenario and derive the conditions under which a secret key can be distilled using the recurrence protocol or the two-way classical distillation, advantage distillation together with one-way postprocessing. From the security conditions, it is shown that a secret key canmore » be distilled from bound entangled states in a much wider range. In addition, I consider the case that in which white noise is added to quantum states and show that the classical distillation protocol still works despite a certain amount of noise although the recurrence protocol does not.« less

  7. Key issues concerning environmental enrichment for laboratory-held fish species.

    PubMed

    Williams, T D; Readman, G D; Owen, S F

    2009-04-01

    An improved knowledge and understanding of the fundamental biological requirements is needed for many of the species of fish held in captivity and, without this knowledge it is difficult to determine the optimal conditions for laboratory culture. The aim of this paper is to review the key issues concerning environmental enrichment for laboratory-held fish species and identify where improvements are required. It provides background information on environmental enrichment, describes enrichment techniques currently used in aquatic ecotoxicology studies, identifies potential restrictions in their use and discusses why more detailed and species-specific guidance is needed.

  8. Improved key-rate bounds for practical decoy-state quantum-key-distribution systems

    NASA Astrophysics Data System (ADS)

    Zhang, Zhen; Zhao, Qi; Razavi, Mohsen; Ma, Xiongfeng

    2017-01-01

    The decoy-state scheme is the most widely implemented quantum-key-distribution protocol in practice. In order to account for the finite-size key effects on the achievable secret key generation rate, a rigorous statistical fluctuation analysis is required. Originally, a heuristic Gaussian-approximation technique was used for this purpose, which, despite its analytical convenience, was not sufficiently rigorous. The fluctuation analysis has recently been made rigorous by using the Chernoff bound. There is a considerable gap, however, between the key-rate bounds obtained from these techniques and that obtained from the Gaussian assumption. Here we develop a tighter bound for the decoy-state method, which yields a smaller failure probability. This improvement results in a higher key rate and increases the maximum distance over which secure key exchange is possible. By optimizing the system parameters, our simulation results show that our method almost closes the gap between the two previously proposed techniques and achieves a performance similar to that of conventional Gaussian approximations.

  9. Quantum Public Key Cryptosystem Based on Bell States

    NASA Astrophysics Data System (ADS)

    Wu, WanQing; Cai, QingYu; Zhang, HuanGuo; Liang, XiaoYan

    2017-11-01

    Classical public key cryptosystems ( P K C), such as R S A, E I G a m a l, E C C, are no longer secure in quantum algorithms, and quantum cryptography has become a novel research topic. In this paper we present a quantum asymmetrical cryptosystem i.e. quantum public key cryptosystem ( Q P K C) based on the Bell states. In particular, in the proposed QPKC the public key are given by the first n particles of Bell states and generalized Pauli operations. The corresponding secret key are the last n particles of Bell states and the inverse of generalized Pauli operations. The proposed QPKC encrypts the message using a public key and decrypts the ciphertext using a private key. By H o l e v o ' s theorem, we proved the security of the secret key and messages during the QPKC.

  10. Practical decoy state for quantum key distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma Xiongfeng; Qi Bing; Zhao Yi

    2005-07-15

    Decoy states have recently been proposed as a useful method for substantially improving the performance of quantum key distribution (QKD). Here, we present a general theory of the decoy state protocol based on only two decoy states and one signal state. We perform optimization on the choice of intensities of the two decoy states and the signal state. Our result shows that a decoy state protocol with only two types of decoy states - the vacuum and a weak decoy state - asymptotically approaches the theoretical limit of the most general type of decoy state protocol (with an infinite numbermore » of decoy states). We also present a one-decoy-state protocol. Moreover, we provide estimations on the effects of statistical fluctuations and suggest that, even for long-distance (larger than 100 km) QKD, our two-decoy-state protocol can be implemented with only a few hours of experimental data. In conclusion, decoy state quantum key distribution is highly practical.« less

  11. Securing quantum key distribution systems using fewer states

    NASA Astrophysics Data System (ADS)

    Islam, Nurul T.; Lim, Charles Ci Wen; Cahall, Clinton; Kim, Jungsang; Gauthier, Daniel J.

    2018-04-01

    Quantum key distribution (QKD) allows two remote users to establish a secret key in the presence of an eavesdropper. The users share quantum states prepared in two mutually unbiased bases: one to generate the key while the other monitors the presence of the eavesdropper. Here, we show that a general d -dimension QKD system can be secured by transmitting only a subset of the monitoring states. In particular, we find that there is no loss in the secure key rate when dropping one of the monitoring states. Furthermore, it is possible to use only a single monitoring state if the quantum bit error rates are low enough. We apply our formalism to an experimental d =4 time-phase QKD system, where only one monitoring state is transmitted, and obtain a secret key rate of 17.4 ±2.8 Mbits/s at a 4 dB channel loss and with a quantum bit error rate of 0.045 ±0.001 and 0.037 ±0.001 in time and phase bases, respectively, which is 58.4% of the secret key rate that can be achieved with the full setup. This ratio can be increased, potentially up to 100%, if the error rates in time and phase basis are reduced. Our results demonstrate that it is possible to substantially simplify the design of high-dimensional QKD systems, including those that use the spatial or temporal degrees of freedom of the photon, and still outperform qubit-based (d =2 ) protocols.

  12. Free-space measurement-device-independent quantum-key-distribution protocol using decoy states with orbital angular momentum

    NASA Astrophysics Data System (ADS)

    Wang, Le; Zhao, Sheng-Mei; Gong, Long-Yan; Cheng, Wei-Wen

    2015-12-01

    In this paper, we propose a measurement-device-independent quantum-key-distribution (MDI-QKD) protocol using orbital angular momentum (OAM) in free space links, named the OAM-MDI-QKD protocol. In the proposed protocol, the OAM states of photons, instead of polarization states, are used as the information carriers to avoid the reference frame alignment, the decoy-state is adopted to overcome the security loophole caused by the weak coherent pulse source, and the high efficient OAM-sorter is adopted as the measurement tool for Charlie to obtain the output OAM state. Here, Charlie may be an untrusted third party. The results show that the authorized users, Alice and Bob, could distill a secret key with Charlie’s successful measurements, and the key generation performance is slightly better than that of the polarization-based MDI-QKD protocol in the two-dimensional OAM cases. Simultaneously, Alice and Bob can reduce the number of flipping the bits in the secure key distillation. It is indicated that a higher key generation rate performance could be obtained by a high dimensional OAM-MDI-QKD protocol because of the unlimited degree of freedom on OAM states. Moreover, the results show that the key generation rate and the transmission distance will decrease as the growth of the strength of atmospheric turbulence (AT) and the link attenuation. In addition, the decoy states used in the proposed protocol can get a considerable good performance without the need for an ideal source. Project supported by the National Natural Science Foundation of China (Grant Nos. 61271238 and 61475075), the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20123223110003), the Natural Science Research Foundation for Universities of Jiangsu Province of China (Grant No. 11KJA510002), the Open Research Fund of Key Laboratory of Broadband Wireless Communication and Sensor Network Technology, Ministry of Education, China (Grant No. NYKL2015011), and the

  13. Continuous variable quantum key distribution with modulated entangled states.

    PubMed

    Madsen, Lars S; Usenko, Vladyslav C; Lassen, Mikael; Filip, Radim; Andersen, Ulrik L

    2012-01-01

    Quantum key distribution enables two remote parties to grow a shared key, which they can use for unconditionally secure communication over a certain distance. The maximal distance depends on the loss and the excess noise of the connecting quantum channel. Several quantum key distribution schemes based on coherent states and continuous variable measurements are resilient to high loss in the channel, but are strongly affected by small amounts of channel excess noise. Here we propose and experimentally address a continuous variable quantum key distribution protocol that uses modulated fragile entangled states of light to greatly enhance the robustness to channel noise. We experimentally demonstrate that the resulting quantum key distribution protocol can tolerate more noise than the benchmark set by the ideal continuous variable coherent state protocol. Our scheme represents a very promising avenue for extending the distance for which secure communication is possible.

  14. Quantum key distribution using continuous-variable non-Gaussian states

    NASA Astrophysics Data System (ADS)

    Borelli, L. F. M.; Aguiar, L. S.; Roversi, J. A.; Vidiella-Barranco, A.

    2016-02-01

    In this work, we present a quantum key distribution protocol using continuous-variable non-Gaussian states, homodyne detection and post-selection. The employed signal states are the photon added then subtracted coherent states (PASCS) in which one photon is added and subsequently one photon is subtracted from the field. We analyze the performance of our protocol, compared with a coherent state-based protocol, for two different attacks that could be carried out by the eavesdropper (Eve). We calculate the secret key rate transmission in a lossy line for a superior channel (beam-splitter) attack, and we show that we may increase the secret key generation rate by using the non-Gaussian PASCS rather than coherent states. We also consider the simultaneous quadrature measurement (intercept-resend) attack, and we show that the efficiency of Eve's attack is substantially reduced if PASCS are used as signal states.

  15. Quantum key distillation from Gaussian states by Gaussian operations.

    PubMed

    Navascués, M; Bae, J; Cirac, J I; Lewestein, M; Sanpera, A; Acín, A

    2005-01-14

    We study the secrecy properties of Gaussian states under Gaussian operations. Although such operations are useless for quantum distillation, we prove that it is possible to distill a secret key secure against any attack from sufficiently entangled Gaussian states with nonpositive partial transposition. Moreover, all such states allow for key distillation, when Eve is assumed to perform finite-size coherent attacks before the reconciliation process.

  16. Continuous Variable Quantum Key Distribution Using Polarized Coherent States

    NASA Astrophysics Data System (ADS)

    Vidiella-Barranco, A.; Borelli, L. F. M.

    We discuss a continuous variables method of quantum key distribution employing strongly polarized coherent states of light. The key encoding is performed using the variables known as Stokes parameters, rather than the field quadratures. Their quantum counterpart, the Stokes operators Ŝi (i=1,2,3), constitute a set of non-commuting operators, being the precision of simultaneous measurements of a pair of them limited by an uncertainty-like relation. Alice transmits a conveniently modulated two-mode coherent state, and Bob randomly measures one of the Stokes parameters of the incoming beam. After performing reconciliation and privacy amplification procedures, it is possible to distill a secret common key. We also consider a non-ideal situation, in which coherent states with thermal noise, instead of pure coherent states, are used for encoding.

  17. Bound entangled states with a private key and their classical counterpart.

    PubMed

    Ozols, Maris; Smith, Graeme; Smolin, John A

    2014-03-21

    Entanglement is a fundamental resource for quantum information processing. In its pure form, it allows quantum teleportation and sharing classical secrets. Realistic quantum states are noisy and their usefulness is only partially understood. Bound-entangled states are central to this question--they have no distillable entanglement, yet sometimes still have a private classical key. We present a construction of bound-entangled states with a private key based on classical probability distributions. From this emerge states possessing a new classical analogue of bound entanglement, distinct from the long-sought bound information. We also find states of smaller dimensions and higher key rates than previously known. Our construction has implications for classical cryptography: we show that existing protocols are insufficient for extracting private key from our distributions due to their "bound-entangled" nature. We propose a simple extension of existing protocols that can extract a key from them.

  18. Key Higher-Education Issues in the States

    ERIC Educational Resources Information Center

    Fischer, Karin; Hebel, Sara

    2007-01-01

    Legislatures are set to convene in January in 43 states. This article presents the key issues that are expected to be debated by legislatures in states this year. These issues include: (1) Annulment of a controversial law in Texas that guarantees students who graduate in the top 10 percent of their high-school classes admission to any public…

  19. Decoy-state quantum key distribution with biased basis choice

    PubMed Central

    Wei, Zhengchao; Wang, Weilong; Zhang, Zhen; Gao, Ming; Ma, Zhi; Ma, Xiongfeng

    2013-01-01

    We propose a quantum key distribution scheme that combines a biased basis choice with the decoy-state method. In this scheme, Alice sends all signal states in the Z basis and decoy states in the X and Z basis with certain probabilities, and Bob measures received pulses with optimal basis choice. This scheme simplifies the system and reduces the random number consumption. From the simulation result taking into account of statistical fluctuations, we find that in a typical experimental setup, the proposed scheme can increase the key rate by at least 45% comparing to the standard decoy-state scheme. In the postprocessing, we also apply a rigorous method to upper bound the phase error rate of the single-photon components of signal states. PMID:23948999

  20. Decoy-state quantum key distribution with biased basis choice.

    PubMed

    Wei, Zhengchao; Wang, Weilong; Zhang, Zhen; Gao, Ming; Ma, Zhi; Ma, Xiongfeng

    2013-01-01

    We propose a quantum key distribution scheme that combines a biased basis choice with the decoy-state method. In this scheme, Alice sends all signal states in the Z basis and decoy states in the X and Z basis with certain probabilities, and Bob measures received pulses with optimal basis choice. This scheme simplifies the system and reduces the random number consumption. From the simulation result taking into account of statistical fluctuations, we find that in a typical experimental setup, the proposed scheme can increase the key rate by at least 45% comparing to the standard decoy-state scheme. In the postprocessing, we also apply a rigorous method to upper bound the phase error rate of the single-photon components of signal states.

  1. Finite-key analysis for the 1-decoy state QKD protocol

    NASA Astrophysics Data System (ADS)

    Rusca, Davide; Boaron, Alberto; Grünenfelder, Fadri; Martin, Anthony; Zbinden, Hugo

    2018-04-01

    It has been shown that in the asymptotic case of infinite-key length, the 2-decoy state Quantum Key Distribution (QKD) protocol outperforms the 1-decoy state protocol. Here, we present a finite-key analysis of the 1-decoy method. Interestingly, we find that for practical block sizes of up to 108 bits, the 1-decoy protocol achieves for almost all experimental settings higher secret key rates than the 2-decoy protocol. Since using only one decoy is also easier to implement, we conclude that it is the best choice for QKD, in most common practical scenarios.

  2. Novel Multi-Party Quantum Key Agreement Protocol with G-Like States and Bell States

    NASA Astrophysics Data System (ADS)

    Min, Shi-Qi; Chen, Hua-Ying; Gong, Li-Hua

    2018-03-01

    A significant aspect of quantum cryptography is quantum key agreement (QKA), which ensures the security of key agreement protocols by quantum information theory. The fairness of an absolute security multi-party quantum key agreement (MQKA) protocol demands that all participants can affect the protocol result equally so as to establish a shared key and that nobody can determine the shared key by himself/herself. We found that it is difficult for the existing multi-party quantum key agreement protocol to withstand the collusion attacks. Put differently, it is possible for several cooperated and untruthful participants to determine the final key without being detected. To address this issue, based on the entanglement swapping between G-like state and Bell states, a new multi-party quantum key agreement protocol is put forward. The proposed protocol makes full use of EPR pairs as quantum resources, and adopts Bell measurement and unitary operation to share a secret key. Besides, the proposed protocol is fair, secure and efficient without involving a third party quantum center. It demonstrates that the protocol is capable of protecting users' privacy and meeting the requirement of fairness. Moreover, it is feasible to carry out the protocol with existing technologies.

  3. Novel Multi-Party Quantum Key Agreement Protocol with G-Like States and Bell States

    NASA Astrophysics Data System (ADS)

    Min, Shi-Qi; Chen, Hua-Ying; Gong, Li-Hua

    2018-06-01

    A significant aspect of quantum cryptography is quantum key agreement (QKA), which ensures the security of key agreement protocols by quantum information theory. The fairness of an absolute security multi-party quantum key agreement (MQKA) protocol demands that all participants can affect the protocol result equally so as to establish a shared key and that nobody can determine the shared key by himself/herself. We found that it is difficult for the existing multi-party quantum key agreement protocol to withstand the collusion attacks. Put differently, it is possible for several cooperated and untruthful participants to determine the final key without being detected. To address this issue, based on the entanglement swapping between G-like state and Bell states, a new multi-party quantum key agreement protocol is put forward. The proposed protocol makes full use of EPR pairs as quantum resources, and adopts Bell measurement and unitary operation to share a secret key. Besides, the proposed protocol is fair, secure and efficient without involving a third party quantum center. It demonstrates that the protocol is capable of protecting users' privacy and meeting the requirement of fairness. Moreover, it is feasible to carry out the protocol with existing technologies.

  4. 42 CFR 493.645 - Additional fee(s) applicable to approved State laboratory programs and laboratories issued a...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS General Administration § 493.645 Additional fee(s) applicable to approved State laboratory programs and... laboratory programs and laboratories issued a certificate of accreditation, certificate of waiver, or...

  5. [The microbiology laboratory: a key participant in transplantation].

    PubMed

    Pérez, José L; Pumarola, Tomàs

    2007-04-01

    Together with organ rejection, infectious complications are still the most important cause of morbidity and mortality in organ transplant recipients. Many infectious complications have an exogenous origin, including those produced by organ-transmitted pathogens, whereas others are caused by latent microorganisms that become reactivated in the recipient. Accurate pre-transplantation assessment of the organ donor as well as the recipient can prevent some infectious complications or reduce their detrimental effects during the post-transplant period. A wide range of primary and opportunistic microorganisms can affect transplant recipients, and a detailed description of these pathogens is beyond the scope of this study. However, the importance of microbiology laboratories in centers with transplant programs and the need for integration and active participation of clinical microbiologists in multidisciplinary transplant teams should be emphasized. The work of these professionals is a key requisite to establish accurate diagnoses of infectious complications, which will benefit the patient and optimize the expenditure of resources.

  6. Multi-party quantum key agreement with five-qubit brown states

    NASA Astrophysics Data System (ADS)

    Cai, Tao; Jiang, Min; Cao, Gang

    2018-05-01

    In this paper, we propose a multi-party quantum key agreement protocol with five-qubit brown states and single-qubit measurements. Our multi-party protocol ensures each participant to contribute equally to the agreement key. Each party performs three single-qubit unitary operations on three qubits of each brown state. Finally, by measuring brown states and decoding the measurement results, all participants can negotiate a shared secret key without classical bits exchange between them. With the analysis of security, our protocol demonstrates that it can resist against both outsider and participant attacks. Compared with other schemes, it also possesses a higher information efficiency. In terms of physical operation, it requires single-qubit measurements only which weakens the hardware requirements of participant and has a better operating flexibility.

  7. Two-party quantum key agreement with five-particle entangled states

    NASA Astrophysics Data System (ADS)

    He, Ye-Feng; Ma, Wen-Ping

    A two-party quantum key agreement protocol is proposed with five-particle entangled states and the delayed measurement technique. According to the measurement correlation property of five-particle entangled states, two participants can deduce the measurement results of each other’s initial quantum states. As a result, two parties can extract the secret keys of each other by using the publicly announced value or by performing the delayed measurement, respectively. Thus, a shared key is fairly established. Since each particle is transmitted only once in quantum channel, the protocol is congenitally free from the Trojan horse attacks. It is shown that the protocol not only is secure against both participant and outsider attacks but also has no information leakage problem. Moreover, it has high qubit efficiency.

  8. Obtaining patient test results from clinical laboratories: a survey of state law for pharmacists.

    PubMed

    Witry, Matthew J; Doucette, William R

    2009-01-01

    To identify states with laws that restrict to whom clinical laboratories may release copies of laboratory test results and to describe how these laws may affect pharmacists' ability to obtain patient laboratory test results. Researchers examined state statutes and administrative codes for all 50 states and the District of Columbia at the University of Iowa Law Library between June and July 2007. Researchers also consulted with lawyers, state Clinical Laboratory Improvement Amendments officers, and law librarians. Laws relating to the study objective were analyzed. 34 jurisdictions do not restrict the release of laboratory test results, while 17 states have laws that restrict to whom clinical laboratories can send copies of test results. In these states, pharmacists will have to use alternative sources, such as physician offices, to obtain test results. Pharmacists must consider state law before requesting copies of laboratory test results from clinical laboratories. This may be an issue that state pharmacy associations can address to increase pharmacist access to important patient information.

  9. Passive state preparation in the Gaussian-modulated coherent-states quantum key distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, Bing; Evans, Philip G.; Grice, Warren P.

    In the Gaussian-modulated coherent-states (GMCS) quantum key distribution (QKD) protocol, Alice prepares quantum states actively: For each transmission, Alice generates a pair of Gaussian-distributed random numbers, encodes them on a weak coherent pulse using optical amplitude and phase modulators, and then transmits the Gaussian-modulated weak coherent pulse to Bob. Here we propose a passive state preparation scheme using a thermal source. In our scheme, Alice splits the output of a thermal source into two spatial modes using a beam splitter. She measures one mode locally using conjugate optical homodyne detectors, and transmits the other mode to Bob after applying appropriatemore » optical attenuation. Under normal conditions, Alice's measurement results are correlated to Bob's, and they can work out a secure key, as in the active state preparation scheme. Given the initial thermal state generated by the source is strong enough, this scheme can tolerate high detector noise at Alice's side. Furthermore, the output of the source does not need to be single mode, since an optical homodyne detector can selectively measure a single mode determined by the local oscillator. Preliminary experimental results suggest that the proposed scheme could be implemented using an off-the-shelf amplified spontaneous emission source.« less

  10. Passive state preparation in the Gaussian-modulated coherent-states quantum key distribution

    DOE PAGES

    Qi, Bing; Evans, Philip G.; Grice, Warren P.

    2018-01-01

    In the Gaussian-modulated coherent-states (GMCS) quantum key distribution (QKD) protocol, Alice prepares quantum states actively: For each transmission, Alice generates a pair of Gaussian-distributed random numbers, encodes them on a weak coherent pulse using optical amplitude and phase modulators, and then transmits the Gaussian-modulated weak coherent pulse to Bob. Here we propose a passive state preparation scheme using a thermal source. In our scheme, Alice splits the output of a thermal source into two spatial modes using a beam splitter. She measures one mode locally using conjugate optical homodyne detectors, and transmits the other mode to Bob after applying appropriatemore » optical attenuation. Under normal conditions, Alice's measurement results are correlated to Bob's, and they can work out a secure key, as in the active state preparation scheme. Given the initial thermal state generated by the source is strong enough, this scheme can tolerate high detector noise at Alice's side. Furthermore, the output of the source does not need to be single mode, since an optical homodyne detector can selectively measure a single mode determined by the local oscillator. Preliminary experimental results suggest that the proposed scheme could be implemented using an off-the-shelf amplified spontaneous emission source.« less

  11. Experimental realization of equiangular three-state quantum key distribution

    PubMed Central

    Schiavon, Matteo; Vallone, Giuseppe; Villoresi, Paolo

    2016-01-01

    Quantum key distribution using three states in equiangular configuration combines a security threshold comparable with the one of the Bennett-Brassard 1984 protocol and a quantum bit error rate (QBER) estimation that does not need to reveal part of the key. We implement an entanglement-based version of the Renes 2004 protocol, using only passive optic elements in a linear scheme for the positive-operator valued measure (POVM), generating an asymptotic secure key rate of more than 10 kbit/s, with a mean QBER of 1.6%. We then demonstrate its security in the case of finite key and evaluate the key rate for both collective and general attacks. PMID:27465643

  12. Assessment of biosafety precautions in Khartoum state diagnostic laboratories, Sudan

    PubMed Central

    Elduma, Adel Hussein

    2012-01-01

    Background This study was conducted to evaluate the biosafety precautions that applied by diagnostic laboratories in Khartoum state, 2009. Methods A total number of 190 laboratories were surveyed about their compliance with standard biosafety precautions. These laboratories included 51 (27%) laboratories from government, 75 (39%) from private sectors and 64 (34%) laboratories belong to organization providing health care services. Results The study found that 32 (16.8%) of laboratories appointed biosafety officers. Only, ten (5.2%) participated in training about response to fire emergency, and 28 (14.7%) reported the laboratory accident occurred during work. 45 (23.7%) laboratories had a written standard operation procedures (SOPs), and 35 (18.4%) had written procedures for the lean-up of spills. Moreover, biosafety cabinet was found in 11 (5.8%) laboratories, autoclave in 28 (14.7%) and incinerator in only two (1.1%) laboratories. Sharp disposable containers were found in 84 (44.2%). Fire alarm system was found in 2 (1.1%) laboratories, fire extinguisher in 39 (20.5%) laboratories, and fire emergency exit found in 14 (7.4%) laboratories. Furthermore, 19 (10%) laboratories had a hepatitis B virus vaccination programme, 5 (6.2%) applied BCG vaccine, and 2 (1.1%0) vaccinated the staff against influenza. Conclusion The study concluded that the standards biosafety precautions adopted by the diagnostic laboratories in Khartoum state was very low. Further, the laboratory personnel awareness towards biosafety principles implementation was very low too. PMID:22514753

  13. Assessment of biosafety precautions in Khartoum state diagnostic laboratories, Sudan.

    PubMed

    Elduma, Adel Hussein

    2012-01-01

    This study was conducted to evaluate the biosafety precautions that applied by diagnostic laboratories in Khartoum state, 2009. A total number of 190 laboratories were surveyed about their compliance with standard biosafety precautions. These laboratories included 51 (27%) laboratories from government, 75 (39%) from private sectors and 64 (34%) laboratories belong to organization providing health care services. The study found that 32 (16.8%) of laboratories appointed biosafety officers. Only, ten (5.2%) participated in training about response to fire emergency, and 28 (14.7%) reported the laboratory accident occurred during work. 45 (23.7%) laboratories had a written standard operation procedures (SOPs), and 35 (18.4%) had written procedures for the lean-up of spills. Moreover, biosafety cabinet was found in 11 (5.8%) laboratories, autoclave in 28 (14.7%) and incinerator in only two (1.1%) laboratories. Sharp disposable containers were found in 84 (44.2%). Fire alarm system was found in 2 (1.1%) laboratories, fire extinguisher in 39 (20.5%) laboratories, and fire emergency exit found in 14 (7.4%) laboratories. Furthermore, 19 (10%) laboratories had a hepatitis B virus vaccination programme, 5 (6.2%) applied BCG vaccine, and 2 (1.1%0) vaccinated the staff against influenza. The study concluded that the standards biosafety precautions adopted by the diagnostic laboratories in Khartoum state was very low. Further, the laboratory personnel awareness towards biosafety principles implementation was very low too.

  14. Evaluating laboratory key performance using quality indicators in Alexandria University Hospital Clinical Chemistry Laboratories.

    PubMed

    Rizk, Mostafa M; Zaki, Adel; Hossam, Nermine; Aboul-Ela, Yasmin

    2014-12-01

    The performance of clinical laboratories plays a fundamental role in the quality and effectiveness of healthcare. To evaluate the laboratory performance in Alexandria University Hospital Clinical Laboratories using key quality indicators and to compare the performance before and after an improvement plan based on ISO 15189 standards. The study was carried out on inpatient samples for a period of 7 months that was divided into three phases: phase I included data collection for evaluation of the existing process before improvement (March-May 2012); an intermediate phase, which included corrective, preventive action, quality initiative and steps for improvement (June 2012); and phase II, which included data collection for evaluation of the process after improvement (July 2012-September 2012). In terms of the preanalytical indicators, incomplete request forms in phase I showed that the total number of received requests were 31 944, with a percentage of defected request of 33.66%; whereas in phase II, there was a significant reduction in all defected request items (P<0.001) with a percentage of defected requests of 9.64%. As for the analytical indicators, the proficiency testing accuracy score in phase I showed poor performance of 10 analytes in which total error (TE) exceeded total error allowable (TEa), with a corresponding sigma value of less than 3, which indicates test problems and an unreliable method. The remaining analytes showed an acceptable performance in which TE did not exceed the TEa, with a sigma value of more than 6. Following an intervention of 3 months, the performance showed marked improvement. Error tracking in phase I showed a TE of (5.11%), whereas in phase II it was reduced to 2.48% (P<0.001).For the postanalytical indicators, our results in phase I showed that the percentage of nonreported critical results was 26.07%. In phase II, there was a significant improvement (P<0.001). The percentage of nonreported results was 11.37%, the reasons were

  15. Making the decoy-state measurement-device-independent quantum key distribution practically useful

    NASA Astrophysics Data System (ADS)

    Zhou, Yi-Heng; Yu, Zong-Wen; Wang, Xiang-Bin

    2016-04-01

    The relatively low key rate seems to be the major barrier to its practical use for the decoy-state measurement-device-independent quantum key distribution (MDI-QKD). We present a four-intensity protocol for the decoy-state MDI-QKD that hugely raises the key rate, especially in the case in which the total data size is not large. Also, calculations show that our method makes it possible for secure private communication with fresh keys generated from MDI-QKD with a delay time of only a few seconds.

  16. Security of six-state quantum key distribution protocol with threshold detectors

    PubMed Central

    Kato, Go; Tamaki, Kiyoshi

    2016-01-01

    The security of quantum key distribution (QKD) is established by a security proof, and the security proof puts some assumptions on the devices consisting of a QKD system. Among such assumptions, security proofs of the six-state protocol assume the use of photon number resolving (PNR) detector, and as a result the bit error rate threshold for secure key generation for the six-state protocol is higher than that for the BB84 protocol. Unfortunately, however, this type of detector is demanding in terms of technological level compared to the standard threshold detector, and removing the necessity of such a detector enhances the feasibility of the implementation of the six-state protocol. Here, we develop the security proof for the six-state protocol and show that we can use the threshold detector for the six-state protocol. Importantly, the bit error rate threshold for the key generation for the six-state protocol (12.611%) remains almost the same as the one (12.619%) that is derived from the existing security proofs assuming the use of PNR detectors. This clearly demonstrates feasibility of the six-state protocol with practical devices. PMID:27443610

  17. Addressing the key communication barriers between microbiology laboratories and clinical units: a qualitative study

    PubMed Central

    Skodvin, Brita; Aase, Karina; Brekken, Anita Løvås; Charani, Esmita; Lindemann, Paul Christoffer; Smith, Ingrid

    2017-01-01

    Abstract Background Many countries are on the brink of establishing antibiotic stewardship programmes in hospitals nationwide. In a previous study we found that communication between microbiology laboratories and clinical units is a barrier to implementing efficient antibiotic stewardship programmes in Norway. We have now addressed the key communication barriers between microbiology laboratories and clinical units from a laboratory point of view. Methods Qualitative semi-structured interviews were conducted with 18 employees (managers, doctors and technicians) from six diverse Norwegian microbiological laboratories, representing all four regional health authorities. Interviews were recorded and transcribed verbatim. Thematic analysis was applied, identifying emergent themes, subthemes and corresponding descriptions. Results The main barrier to communication is disruption involving specimen logistics, information on request forms, verbal reporting of test results and information transfer between poorly integrated IT systems. Furthermore, communication is challenged by lack of insight into each other’s area of expertise and limited provision of laboratory services, leading to prolonged turnaround time, limited advisory services and restricted opening hours. Conclusions Communication between microbiology laboratories and clinical units can be improved by a review of testing processes, educational programmes to increase insights into the other’s area of expertise, an evaluation of work tasks and expansion of rapid and point-of-care test services. Antibiotic stewardship programmes may serve as a valuable framework to establish these measures. PMID:28633405

  18. Quantum key distribution with passive decoy state selection

    NASA Astrophysics Data System (ADS)

    Mauerer, Wolfgang; Silberhorn, Christine

    2007-05-01

    We propose a quantum key distribution scheme which closely matches the performance of a perfect single photon source. It nearly attains the physical upper bound in terms of key generation rate and maximally achievable distance. Our scheme relies on a practical setup based on a parametric downconversion source and present day, nonideal photon-number detection. Arbitrary experimental imperfections which lead to bit errors are included. We select decoy states by classical postprocessing. This allows one to improve the effective signal statistics and achievable distance.

  19. Addressing the key communication barriers between microbiology laboratories and clinical units: a qualitative study.

    PubMed

    Skodvin, Brita; Aase, Karina; Brekken, Anita Løvås; Charani, Esmita; Lindemann, Paul Christoffer; Smith, Ingrid

    2017-09-01

    Many countries are on the brink of establishing antibiotic stewardship programmes in hospitals nationwide. In a previous study we found that communication between microbiology laboratories and clinical units is a barrier to implementing efficient antibiotic stewardship programmes in Norway. We have now addressed the key communication barriers between microbiology laboratories and clinical units from a laboratory point of view. Qualitative semi-structured interviews were conducted with 18 employees (managers, doctors and technicians) from six diverse Norwegian microbiological laboratories, representing all four regional health authorities. Interviews were recorded and transcribed verbatim. Thematic analysis was applied, identifying emergent themes, subthemes and corresponding descriptions. The main barrier to communication is disruption involving specimen logistics, information on request forms, verbal reporting of test results and information transfer between poorly integrated IT systems. Furthermore, communication is challenged by lack of insight into each other's area of expertise and limited provision of laboratory services, leading to prolonged turnaround time, limited advisory services and restricted opening hours. Communication between microbiology laboratories and clinical units can be improved by a review of testing processes, educational programmes to increase insights into the other's area of expertise, an evaluation of work tasks and expansion of rapid and point-of-care test services. Antibiotic stewardship programmes may serve as a valuable framework to establish these measures. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy.

  20. State 'laboratories' test health care reform solutions.

    PubMed

    Elliott, B A

    1993-02-01

    Widely recognized by the states as a pressing policy issue, health care reform appears to have moved up on the national policy agenda as well. President Clinton has promised to address the issue during his first 100 days in office. Previously, however, the federal government has been deadlocked on health care reform, leaving the states to become the laboratories for developing and testing proposed solutions to our health care crisis. By passing MinnesotaCare in last year's legislative session, Minnesota joined the growing number of states attempting to provide access to affordable, quality health care to their citizens.

  1. Quantum key distribution using gaussian-modulated coherent states

    NASA Astrophysics Data System (ADS)

    Grosshans, Frédéric; Van Assche, Gilles; Wenger, Jérôme; Brouri, Rosa; Cerf, Nicolas J.; Grangier, Philippe

    2003-01-01

    Quantum continuous variables are being explored as an alternative means to implement quantum key distribution, which is usually based on single photon counting. The former approach is potentially advantageous because it should enable higher key distribution rates. Here we propose and experimentally demonstrate a quantum key distribution protocol based on the transmission of gaussian-modulated coherent states (consisting of laser pulses containing a few hundred photons) and shot-noise-limited homodyne detection; squeezed or entangled beams are not required. Complete secret key extraction is achieved using a reverse reconciliation technique followed by privacy amplification. The reverse reconciliation technique is in principle secure for any value of the line transmission, against gaussian individual attacks based on entanglement and quantum memories. Our table-top experiment yields a net key transmission rate of about 1.7 megabits per second for a loss-free line, and 75 kilobits per second for a line with losses of 3.1dB. We anticipate that the scheme should remain effective for lines with higher losses, particularly because the present limitations are essentially technical, so that significant margin for improvement is available on both the hardware and software.

  2. Multiparty quantum key agreement protocol based on locally indistinguishable orthogonal product states

    NASA Astrophysics Data System (ADS)

    Jiang, Dong-Huan; Xu, Guang-Bao

    2018-07-01

    Based on locally indistinguishable orthogonal product states, we propose a novel multiparty quantum key agreement (QKA) protocol. In this protocol, the private key information of each party is encoded as some orthogonal product states that cannot be perfectly distinguished by local operations and classical communications. To ensure the security of the protocol with small amount of decoy particles, the different particles of each product state are transmitted separately. This protocol not only can make each participant fairly negotiate a shared key, but also can avoid information leakage in the maximum extent. We give a detailed security proof of this protocol. From comparison result with the existing QKA protocols, we can know that the new protocol is more efficient.

  3. The State Laboratory of Hygiene's role in terrorism preparedness and response.

    PubMed

    Hintzman, Peggy L

    2003-01-01

    In the fall of 2001, the national public health system found itself responding to acts of terrorism. The intentional release of Bacillus anthracis spores on the East Coast tested the capacity of all state public health laboratories to respond. The impact on the public health system extended to the Wisconsin State Laboratory of Hygiene (WSLH). Fortunately, participation in the National Laboratory Response Network helped the WSLH meet the challenge of 24 hour/7 days a week coverage, and subsequent federal funding increases have enabled the WSLH to expand its technical capabilities and provide training and outreach to other Wisconsin laboratories to prepare them for their roles in man-made or naturally-occurring public health emergencies.

  4. Security proof of continuous-variable quantum key distribution using three coherent states

    NASA Astrophysics Data System (ADS)

    Brádler, Kamil; Weedbrook, Christian

    2018-02-01

    We introduce a ternary quantum key distribution (QKD) protocol and asymptotic security proof based on three coherent states and homodyne detection. Previous work had considered the binary case of two coherent states and here we nontrivially extend this to three. Our motivation is to leverage the practical benefits of both discrete and continuous (Gaussian) encoding schemes creating a best-of-both-worlds approach; namely, the postprocessing of discrete encodings and the hardware benefits of continuous ones. We present a thorough and detailed security proof in the limit of infinite signal states which allows us to lower bound the secret key rate. We calculate this is in the context of collective eavesdropping attacks and reverse reconciliation postprocessing. Finally, we compare the ternary coherent state protocol to other well-known QKD schemes (and fundamental repeaterless limits) in terms of secret key rates and loss.

  5. Bit-Oriented Quantum Public-Key Cryptosystem Based on Bell States

    NASA Astrophysics Data System (ADS)

    Wu, WanQing; Cai, QingYu; Zhang, HuanGuo; Liang, XiaoYan

    2018-02-01

    Quantum public key encryption system provides information confidentiality using quantum mechanics. This paper presents a quantum public key cryptosystem (Q P K C) based on the Bell states. By H o l e v o's theorem, the presented scheme provides the security of the secret key using one-wayness during the QPKC. While the QPKC scheme is information theoretic security under chosen plaintext attack (C P A). Finally some important features of presented QPKC scheme can be compared with other QPKC scheme.

  6. Bit-Oriented Quantum Public-Key Cryptosystem Based on Bell States

    NASA Astrophysics Data System (ADS)

    Wu, WanQing; Cai, QingYu; Zhang, HuanGuo; Liang, XiaoYan

    2018-06-01

    Quantum public key encryption system provides information confidentiality using quantum mechanics. This paper presents a quantum public key cryptosystem ( Q P K C) based on the Bell states. By H o l e v o' s theorem, the presented scheme provides the security of the secret key using one-wayness during the QPKC. While the QPKC scheme is information theoretic security under chosen plaintext attack ( C P A). Finally some important features of presented QPKC scheme can be compared with other QPKC scheme.

  7. Squeezed-state quantum key distribution with a Rindler observer

    NASA Astrophysics Data System (ADS)

    Zhou, Jian; Shi, Ronghua; Guo, Ying

    2018-03-01

    Lengthening the maximum transmission distance of quantum key distribution plays a vital role in quantum information processing. In this paper, we propose a directional squeezed-state protocol with signals detected by a Rindler observer in the relativistic quantum field framework. We derive an analytical solution to the transmission problem of squeezed states from the inertial sender to the accelerated receiver. The variance of the involved signal mode is closer to optimality than that of the coherent-state-based protocol. Simulation results show that the proposed protocol has better performance than the coherent-state counterpart especially in terms of the maximal transmission distance.

  8. Survey of safety practices among hospital laboratories in Oromia Regional State, Ethiopia.

    PubMed

    Sewunet, Tsegaye; Kebede, Wakjira; Wondafrash, Beyene; Workalemau, Bereket; Abebe, Gemeda

    2014-10-01

    Unsafe working practices, working environments, disposable waste products, and chemicals in clinical laboratories contribute to infectious and non-infectious hazards. Staffs, the community, and patients are less safe. Furthermore, such practices compromise the quality of laboratory services. We conducted a study to describe safety practices in public hospital laboratories of Oromia Regional State, Ethiopia. Randomly selected ten public hospital laboratories in Oromia Regional State were studied from Oct 2011- Feb 2012. Self-administered structured questionnaire and observation checklists were used for data collection. The respondents were heads of the laboratories, senior technicians, and safety officers. The questionnaire addressed biosafety label, microbial hazards, chemical hazards, physical/mechanical hazards, personal protective equipment, first aid kits and waste disposal system. The data was analyzed using descriptive analysis with SPSS version16 statistical software. All of the respondents reported none of the hospital laboratories were labeled with the appropriate safety label and safety symbols. These respondents also reported they may contain organisms grouped under risk group IV in the absence of microbiological safety cabinets. Overall, the respondents reported that there were poor safety regulations or standards in their laboratories. There were higher risks of microbial, chemical and physical/mechanical hazards. Laboratory safety in public hospitals of Oromia Regional State is below the standard. The laboratory workers are at high risk of combined physical, chemical and microbial hazards. Prompt recognition of the problem and immediate action is mandatory to ensure safe working environment in health laboratories.

  9. Continuous-variable quantum key distribution with a leakage from state preparation

    NASA Astrophysics Data System (ADS)

    Derkach, Ivan; Usenko, Vladyslav C.; Filip, Radim

    2017-12-01

    We address side-channel leakage in a trusted preparation station of continuous-variable quantum key distribution with coherent and squeezed states. We consider two different scenarios: multimode Gaussian modulation, directly accessible to an eavesdropper, or side-channel loss of the signal states prior to the modulation stage. We show the negative impact of excessive modulation on both the coherent- and squeezed-state protocols. The impact is more pronounced for squeezed-state protocols and may require optimization of squeezing in the case of noisy quantum channels. Further, we demonstrate that the coherent-state protocol is immune to side-channel signal state leakage prior to modulation, while the squeezed-state protocol is vulnerable to such attacks, becoming more sensitive to the noise in the channel. In the general case of noisy quantum channels the signal squeezing can be optimized to provide best performance of the protocol in the presence of side-channel leakage prior to modulation. Our results demonstrate that leakage from the trusted source in continuous-variable quantum key distribution should not be underestimated and squeezing optimization is needed to overcome coherent state protocols.

  10. An improved scheme on decoy-state method for measurement-device-independent quantum key distribution.

    PubMed

    Wang, Dong; Li, Mo; Guo, Guang-Can; Wang, Qin

    2015-10-14

    Quantum key distribution involving decoy-states is a significant application of quantum information. By using three-intensity decoy-states of single-photon-added coherent sources, we propose a practically realizable scheme on quantum key distribution which approaches very closely the ideal asymptotic case of an infinite number of decoy-states. We make a comparative study between this scheme and two other existing ones, i.e., two-intensity decoy-states with single-photon-added coherent sources, and three-intensity decoy-states with weak coherent sources. Through numerical analysis, we demonstrate the advantages of our scheme in secure transmission distance and the final key generation rate.

  11. An improved scheme on decoy-state method for measurement-device-independent quantum key distribution

    PubMed Central

    Wang, Dong; Li, Mo; Guo, Guang-Can; Wang, Qin

    2015-01-01

    Quantum key distribution involving decoy-states is a significant application of quantum information. By using three-intensity decoy-states of single-photon-added coherent sources, we propose a practically realizable scheme on quantum key distribution which approaches very closely the ideal asymptotic case of an infinite number of decoy-states. We make a comparative study between this scheme and two other existing ones, i.e., two-intensity decoy-states with single-photon-added coherent sources, and three-intensity decoy-states with weak coherent sources. Through numerical analysis, we demonstrate the advantages of our scheme in secure transmission distance and the final key generation rate. PMID:26463580

  12. Quantum key distribution session with 16-dimensional photonic states.

    PubMed

    Etcheverry, S; Cañas, G; Gómez, E S; Nogueira, W A T; Saavedra, C; Xavier, G B; Lima, G

    2013-01-01

    The secure transfer of information is an important problem in modern telecommunications. Quantum key distribution (QKD) provides a solution to this problem by using individual quantum systems to generate correlated bits between remote parties, that can be used to extract a secret key. QKD with D-dimensional quantum channels provides security advantages that grow with increasing D. However, the vast majority of QKD implementations has been restricted to two dimensions. Here we demonstrate the feasibility of using higher dimensions for real-world quantum cryptography by performing, for the first time, a fully automated QKD session based on the BB84 protocol with 16-dimensional quantum states. Information is encoded in the single-photon transverse momentum and the required states are dynamically generated with programmable spatial light modulators. Our setup paves the way for future developments in the field of experimental high-dimensional QKD.

  13. Quantum key distribution session with 16-dimensional photonic states

    NASA Astrophysics Data System (ADS)

    Etcheverry, S.; Cañas, G.; Gómez, E. S.; Nogueira, W. A. T.; Saavedra, C.; Xavier, G. B.; Lima, G.

    2013-07-01

    The secure transfer of information is an important problem in modern telecommunications. Quantum key distribution (QKD) provides a solution to this problem by using individual quantum systems to generate correlated bits between remote parties, that can be used to extract a secret key. QKD with D-dimensional quantum channels provides security advantages that grow with increasing D. However, the vast majority of QKD implementations has been restricted to two dimensions. Here we demonstrate the feasibility of using higher dimensions for real-world quantum cryptography by performing, for the first time, a fully automated QKD session based on the BB84 protocol with 16-dimensional quantum states. Information is encoded in the single-photon transverse momentum and the required states are dynamically generated with programmable spatial light modulators. Our setup paves the way for future developments in the field of experimental high-dimensional QKD.

  14. Security of a single-state semi-quantum key distribution protocol

    NASA Astrophysics Data System (ADS)

    Zhang, Wei; Qiu, Daowen; Mateus, Paulo

    2018-06-01

    Semi-quantum key distribution protocols are allowed to set up a secure secret key between two users. Compared with their full quantum counterparts, one of the two users is restricted to perform some "classical" or "semi-quantum" operations, which potentially makes them easily realizable by using less quantum resource. However, the semi-quantum key distribution protocols mainly rely on a two-way quantum channel. The eavesdropper has two opportunities to intercept the quantum states transmitted in the quantum communication stage. It may allow the eavesdropper to get more information and make the security analysis more complicated. In the past ten years, many semi-quantum key distribution protocols have been proposed and proved to be robust. However, there are few works concerning their unconditional security. It is doubted that how secure the semi-quantum ones are and how much noise they can tolerate to establish a secure secret key. In this paper, we prove the unconditional security of a single-state semi-quantum key distribution protocol proposed by Zou et al. (Phys Rev A 79:052312, 2009). We present a complete proof from information theory aspect by deriving a lower bound of the protocol's key rate in the asymptotic scenario. Using this bound, we figure out an error threshold value such that for all error rates that are less than this threshold value, the secure secret key can be established between the legitimate users definitely. Otherwise, the users should abort the protocol. We make an illustration of the protocol under the circumstance that the reverse quantum channel is a depolarizing one with parameter q. Additionally, we compare the error threshold value with some full quantum protocols and several existing semi-quantum ones whose unconditional security proofs have been provided recently.

  15. Illustrated Key to Skins and Skulls of Bats in the Southeastern and Mid-Atlantic States

    Treesearch

    Michael A. Menzel; Jennifer M. Menzel; Steven B. Castleberry; James Ozier; W. Mark Ford; John W. Edwards

    2002-01-01

    In teaching students and technicians how to identify the skins and skulls of southeastern bats in the field and laboratory, it was necessary to develop an illustrated key that makes identification both easy and reliable. Many of the existing keys are poorly illustrated, include bat species that are not applicable, and/or contain univariate discriminatory measurements...

  16. Six-State Quantum Key Distribution Using Photons with Orbital Angular Momentum

    NASA Astrophysics Data System (ADS)

    Li, Jun-Lin; Wang, Chuan

    2010-11-01

    A new implementation of high-dimensional quantum key distribution (QKD) protocol is discussed. Using three mutual unbiased bases, we present a d-level six-state QKD protocol that exploits the orbital angular momentum with the spatial mode of the light beam. The protocol shows that the feature of a high capacity since keys are encoded using photon modes in d-level Hilbert space. The devices for state preparation and measurement are also discussed. This protocol has high security and the alignment of shared reference frames is not needed between sender and receiver.

  17. Keys to the Common Genera of Marine Plants Taken Aboard the Orange County Floating Marine Laboratory.

    ERIC Educational Resources Information Center

    Williams, H. R.

    Provided is a dichotomous key to the common genera of marine algae and angiosperms which are taken aboard the Orange County Floating Marine Laboratory. It is designed primarily for use by junior and senior high school students. Drawings of representative members of the various genera are included. This work was prepared under an ESEA Title III…

  18. Multi-party Measurement-Device-Independent Quantum Key Distribution Based on Cluster States

    NASA Astrophysics Data System (ADS)

    Liu, Chuanqi; Zhu, Changhua; Ma, Shuquan; Pei, Changxing

    2018-03-01

    We propose a novel multi-party measurement-device-independent quantum key distribution (MDI-QKD) protocol based on cluster states. A four-photon analyzer which can distinguish all the 16 cluster states serves as the measurement device for four-party MDI-QKD. Any two out of four participants can build secure keys after the analyzers obtains successful outputs and the two participants perform post-processing. We derive a security analysis for the protocol, and analyze the key rates under different values of polarization misalignment. The results show that four-party MDI-QKD is feasible over 280 km in the optical fiber channel when the key rate is about 10- 6 with the polarization misalignment parameter 0.015. Moreover, our work takes an important step toward a quantum communication network.

  19. Quantum key distribution session with 16-dimensional photonic states

    PubMed Central

    Etcheverry, S.; Cañas, G.; Gómez, E. S.; Nogueira, W. A. T.; Saavedra, C.; Xavier, G. B.; Lima, G.

    2013-01-01

    The secure transfer of information is an important problem in modern telecommunications. Quantum key distribution (QKD) provides a solution to this problem by using individual quantum systems to generate correlated bits between remote parties, that can be used to extract a secret key. QKD with D-dimensional quantum channels provides security advantages that grow with increasing D. However, the vast majority of QKD implementations has been restricted to two dimensions. Here we demonstrate the feasibility of using higher dimensions for real-world quantum cryptography by performing, for the first time, a fully automated QKD session based on the BB84 protocol with 16-dimensional quantum states. Information is encoded in the single-photon transverse momentum and the required states are dynamically generated with programmable spatial light modulators. Our setup paves the way for future developments in the field of experimental high-dimensional QKD. PMID:23897033

  20. Continuous operation of four-state continuous-variable quantum key distribution system

    NASA Astrophysics Data System (ADS)

    Matsubara, Takuto; Ono, Motoharu; Oguri, Yusuke; Ichikawa, Tsubasa; Hirano, Takuya; Kasai, Kenta; Matsumoto, Ryutaroh; Tsurumaru, Toyohiro

    2016-10-01

    We report on the development of continuous-variable quantum key distribution (CV-QKD) system that are based on discrete quadrature amplitude modulation (QAM) and homodyne detection of coherent states of light. We use a pulsed light source whose wavelength is 1550 nm and repetition rate is 10 MHz. The CV-QKD system can continuously generate secret key which is secure against entangling cloner attack. Key generation rate is 50 kbps when the quantum channel is a 10 km optical fiber. The CV-QKD system we have developed utilizes the four-state and post-selection protocol [T. Hirano, et al., Phys. Rev. A 68, 042331 (2003).]; Alice randomly sends one of four states {|+/-α⟩,|+/-𝑖α⟩}, and Bob randomly performs x- or p- measurement by homodyne detection. A commercially available balanced receiver is used to realize shot-noise-limited pulsed homodyne detection. GPU cards are used to accelerate the software-based post-processing. We use a non-binary LDPC code for error correction (reverse reconciliation) and the Toeplitz matrix multiplication for privacy amplification.

  1. Hacking on decoy-state quantum key distribution system with partial phase randomization

    NASA Astrophysics Data System (ADS)

    Sun, Shi-Hai; Jiang, Mu-Sheng; Ma, Xiang-Chun; Li, Chun-Yan; Liang, Lin-Mei

    2014-04-01

    Quantum key distribution (QKD) provides means for unconditional secure key transmission between two distant parties. However, in practical implementations, it suffers from quantum hacking due to device imperfections. Here we propose a hybrid measurement attack, with only linear optics, homodyne detection, and single photon detection, to the widely used vacuum + weak decoy state QKD system when the phase of source is partially randomized. Our analysis shows that, in some parameter regimes, the proposed attack would result in an entanglement breaking channel but still be able to trick the legitimate users to believe they have transmitted secure keys. That is, the eavesdropper is able to steal all the key information without discovered by the users. Thus, our proposal reveals that partial phase randomization is not sufficient to guarantee the security of phase-encoding QKD systems with weak coherent states.

  2. Hacking on decoy-state quantum key distribution system with partial phase randomization.

    PubMed

    Sun, Shi-Hai; Jiang, Mu-Sheng; Ma, Xiang-Chun; Li, Chun-Yan; Liang, Lin-Mei

    2014-04-23

    Quantum key distribution (QKD) provides means for unconditional secure key transmission between two distant parties. However, in practical implementations, it suffers from quantum hacking due to device imperfections. Here we propose a hybrid measurement attack, with only linear optics, homodyne detection, and single photon detection, to the widely used vacuum + weak decoy state QKD system when the phase of source is partially randomized. Our analysis shows that, in some parameter regimes, the proposed attack would result in an entanglement breaking channel but still be able to trick the legitimate users to believe they have transmitted secure keys. That is, the eavesdropper is able to steal all the key information without discovered by the users. Thus, our proposal reveals that partial phase randomization is not sufficient to guarantee the security of phase-encoding QKD systems with weak coherent states.

  3. Long-distance measurement-device-independent quantum key distribution with coherent-state superpositions.

    PubMed

    Yin, H-L; Cao, W-F; Fu, Y; Tang, Y-L; Liu, Y; Chen, T-Y; Chen, Z-B

    2014-09-15

    Measurement-device-independent quantum key distribution (MDI-QKD) with decoy-state method is believed to be securely applied to defeat various hacking attacks in practical quantum key distribution systems. Recently, the coherent-state superpositions (CSS) have emerged as an alternative to single-photon qubits for quantum information processing and metrology. Here, in this Letter, CSS are exploited as the source in MDI-QKD. We present an analytical method that gives two tight formulas to estimate the lower bound of yield and the upper bound of bit error rate. We exploit the standard statistical analysis and Chernoff bound to perform the parameter estimation. Chernoff bound can provide good bounds in the long-distance MDI-QKD. Our results show that with CSS, both the security transmission distance and secure key rate are significantly improved compared with those of the weak coherent states in the finite-data case.

  4. Passive decoy-state quantum key distribution with practical light sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Curty, Marcos; Ma, Xiongfeng; Qi, Bing

    2010-02-15

    Decoy states have been proven to be a very useful method for significantly enhancing the performance of quantum key distribution systems with practical light sources. Although active modulation of the intensity of the laser pulses is an effective way of preparing decoy states in principle, in practice passive preparation might be desirable in some scenarios. Typical passive schemes involve parametric down-conversion. More recently, it has been shown that phase-randomized weak coherent pulses (WCP) can also be used for the same purpose [M. Curty et al., Opt. Lett. 34, 3238 (2009).] This proposal requires only linear optics together with a simplemore » threshold photon detector, which shows the practical feasibility of the method. Most importantly, the resulting secret key rate is comparable to the one delivered by an active decoy-state setup with an infinite number of decoy settings. In this article we extend these results, now showing specifically the analysis for other practical scenarios with different light sources and photodetectors. In particular, we consider sources emitting thermal states, phase-randomized WCP, and strong coherent light in combination with several types of photodetectors, like, for instance, threshold photon detectors, photon number resolving detectors, and classical photodetectors. Our analysis includes as well the effect that detection inefficiencies and noise in the form of dark counts shown by current threshold detectors might have on the final secret key rate. Moreover, we provide estimations on the effects that statistical fluctuations due to a finite data size can have in practical implementations.« less

  5. Progress in increasing electronic reporting of laboratory results to public health agencies--United States, 2013.

    PubMed

    2013-09-27

    Electronic reporting of laboratory results to public health agencies can improve public health surveillance for reportable diseases and conditions by making reporting more timely and complete. Since 2010, CDC has provided funding to 57 state, local, and territorial health departments through the Epidemiology and Laboratory Capacity for Infectious Diseases cooperative agreement to assist with improving electronic laboratory reporting (ELR) from clinical and public health laboratories to public health agencies. As part of this agreement, CDC and state and large local health departments are collaborating to monitor ELR implementation in the United States by developing data from each jurisdiction regarding total reporting laboratories, laboratories sending ELR by disease category and message format, and the number of ELR laboratory reports compared with the total number of laboratory reports. At the end of July 2013, 54 of the 57 jurisdictions were receiving at least some laboratory reports through ELR, and approximately 62% of 20 million laboratory reports were being received electronically, compared with 54% in 2012. Continued progress will require collaboration between clinical laboratories, laboratory information management system (LIMS) vendors, and public health agencies.

  6. Practical passive decoy state measurement-device-independent quantum key distribution with unstable sources.

    PubMed

    Liu, Li; Guo, Fen-Zhuo; Wen, Qiao-Yan

    2017-09-12

    Measurement-device-independent quantum key distribution (MDI-QKD) with the active decoy state method can remove all detector loopholes, and resist the imperfections of sources. But it may lead to side channel attacks and break the security of QKD system. In this paper, we apply the passive decoy state method to the MDI-QKD based on polarization encoding mode. Not only all attacks on detectors can be removed, but also the side channel attacks on sources can be overcome. We get that the MDI-QKD with our passive decoy state method can have a performance comparable to the protocol with the active decoy state method. To fit for the demand of practical application, we discuss intensity fluctuation in the security analysis of MDI-QKD protocol using passive decoy state method, and derive the key generation rate for our protocol with intensity fluctuation. It shows that intensity fluctuation has an adverse effect on the key generation rate which is non-negligible, especially in the case of small data size of total transmitting signals and long distance transmission. We give specific simulations on the relationship between intensity fluctuation and the key generation rate. Furthermore, the statistical fluctuation due to the finite length of data is also taken into account.

  7. Annual Report on the State of the DOE National Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2017-01-01

    This first Annual Report to Congress on the State of the DOE National Laboratories provides a comprehensive overview of the Lab system, covering S&T programs, management and strategic planning. The Department committed to prepare this report in response to recommendations from the Congressionally mandated Commission to Review the Effectiveness of the National Energy Laboratories (CRENEL) that the Department should better communicate the value that the Laboratories provide to the Nation. We expect that future annual reports will be much more compact, building on the extensive description of the Laboratories and of the governance structures that are part of this firstmore » report.« less

  8. Quantum cryptography using coherent states: Randomized encryption and key generation

    NASA Astrophysics Data System (ADS)

    Corndorf, Eric

    With the advent of the global optical-telecommunications infrastructure, an increasing number of individuals, companies, and agencies communicate information with one another over public networks or physically-insecure private networks. While the majority of the traffic flowing through these networks requires little or no assurance of secrecy, the same cannot be said for certain communications between banks, between government agencies, within the military, and between corporations. In these arenas, the need to specify some level of secrecy in communications is a high priority. While the current approaches to securing sensitive information (namely the public-key-cryptography infrastructure and deterministic private-key ciphers like AES and 3DES) seem to be cryptographically strong based on empirical evidence, there exist no mathematical proofs of secrecy for any widely deployed cryptosystem. As an example, the ubiquitous public-key cryptosystems infer all of their secrecy from the assumption that factoring of the product of two large primes is necessarily time consuming---something which has not, and perhaps cannot, be proven. Since the 1980s, the possibility of using quantum-mechanical features of light as a physical mechanism for satisfying particular cryptographic objectives has been explored. This research has been fueled by the hopes that cryptosystems based on quantum systems may provide provable levels of secrecy which are at least as valid as quantum mechanics itself. Unfortunately, the most widely considered quantum-cryptographic protocols (BB84 and the Ekert protocol) have serious implementation problems. Specifically, they require quantum-mechanical states which are not readily available, and they rely on unproven relations between intrusion-level detection and the information available to an attacker. As a result, the secrecy level provided by these experimental implementations is entirely unspecified. In an effort to provably satisfy the cryptographic

  9. Performance improvement of eight-state continuous-variable quantum key distribution with an optical amplifier

    NASA Astrophysics Data System (ADS)

    Guo, Ying; Li, Renjie; Liao, Qin; Zhou, Jian; Huang, Duan

    2018-02-01

    Discrete modulation is proven to be beneficial to improving the performance of continuous-variable quantum key distribution (CVQKD) in long-distance transmission. In this paper, we suggest a construct to improve the maximal generated secret key rate of discretely modulated eight-state CVQKD using an optical amplifier (OA) with a slight cost of transmission distance. In the proposed scheme, an optical amplifier is exploited to compensate imperfection of Bob's apparatus, so that the generated secret key rate of eight-state protocol is enhanced. Specifically, we investigate two types of optical amplifiers, phase-insensitive amplifier (PIA) and phase-sensitive amplifier (PSA), and thereby obtain approximately equivalent improved performance for eight-state CVQKD system when applying these two different amplifiers. Numeric simulation shows that the proposed scheme can well improve the generated secret key rate of eight-state CVQKD in both asymptotic limit and finite-size regime. We also show that the proposed scheme can achieve the relatively high-rate transmission at long-distance communication system.

  10. National assessment of capacity in public health, environmental, and agricultural laboratories--United States, 2011.

    PubMed

    2013-03-08

    In 2011, the University of Michigan's Center of Excellence in Public Health Workforce Studies and the Association of Public Health Laboratories (APHL) assessed the workforce and program capacity in U.S. public health, environmental, and agricultural laboratories. During April-August 2011, APHL sent a web-based questionnaire to 105 public health, environmental, and agricultural laboratory directors comprising all 50 state public health laboratories, 41 local public health laboratories, eight environmental laboratories, and six agricultural laboratories. This report summarizes the results of the assessment, which inquired about laboratory capacity, including total number of laboratorians by occupational classification and self-assessed ability to carry out functions in 19 different laboratory program areas. The majority of laboratorians (74%) possessed a bachelor's degree, associate's degree, or a high school education or equivalency; 59% of all laboratorians were classified as laboratory scientists. The greatest percentage of laboratories reported no, minimal, or partial program capacity in toxicology (45%), agricultural microbiology (54%), agricultural chemistry (50%), and education and training for their employees (51%). Nearly 50% of laboratories anticipated that more than 15% of their workforce would retire, resign, or be released within 5 years, lower than the anticipated retirement eligibility rate of 27% projected for state public health workers. However, APHL and partners in local, state, and federal public health should collaborate to address gaps in laboratory capacity and rebuild the workforce pipeline to ensure an adequate future supply of public health laboratorians.

  11. United States Air Force Summer Research Program -- 1993. Volume 8. Phillips Laboratory

    DTIC Science & Technology

    1993-12-01

    Research Program Phillips Laboratory Kirtland Air Force Base Albuquerque. New Mexico Sponsored by...Best Available Copy UNITED STATES AIR FORCE SUMMER RESEARCH PROGRAM -- 1993 SUMMER RESEARCH PROGRAM FINAL REPORTS VOLUME 8 PHILLIPS LABORATORY ...Alabama Box 870344 Tuscaloosa, AL 35487-0344 Final Report for: Graduate Student Research Program Phillips Laboratory , Hanscom AFB Sponsored by: Air

  12. Measurement-device-independent quantum key distribution with source state errors and statistical fluctuation

    NASA Astrophysics Data System (ADS)

    Jiang, Cong; Yu, Zong-Wen; Wang, Xiang-Bin

    2017-03-01

    We show how to calculate the secure final key rate in the four-intensity decoy-state measurement-device-independent quantum key distribution protocol with both source errors and statistical fluctuations with a certain failure probability. Our results rely only on the range of only a few parameters in the source state. All imperfections in this protocol have been taken into consideration without assuming any specific error patterns of the source.

  13. Second United States Microgravity Laboratory: One Year Report. Volume 1

    NASA Technical Reports Server (NTRS)

    Vlasse, M (Editor); McCauley, D. (Editor); Walker, C. (Editor)

    1998-01-01

    This document reports the one year science results for the important and highly successful Second United States Microgravity Laboratory (USML-2). The USML-2 mission consisted of a pressurized Spacelab module where the crew performed experiments. The mission also included a Glovebox where the crew performed additional experiments for the investigators. Together, about 36 major scientific experiments were performed, advancing the state of knowledge in fields such as fluid physics, solidification of metals, alloys, and semiconductors, combustion, and the growth of protein crystals. The results demonstrate the range of quality science that can be conducted utilizing orbital laboratories in microgravity and provide a look forward to a highly productive Space Station era.

  14. Second United States Microgravity Laboratory: One Year Report. Volume 2

    NASA Technical Reports Server (NTRS)

    Vlasse, M. (Editor); McCauley, D. (Editor); Walker, C. (Editor)

    1998-01-01

    This document reports the one year science results for the important and highly successful Second United States Microgravity Laboratory (USML-2). The USML-2 mission consisted of a pressurized Spacelab module where the crew performed experiments. The mission also included a Glovebox where the crew performed additional experiments for the investigators. Together, about 36 major scientific experiments were performed, advancing the state of knowledge in fields such as fluid physics, solidification of metals, alloys, and semiconductors, combustion, and the growth of protein crystals. The results demonstrate the range of quality science that can be conducted utilizing orbital laboratories in microgravity and provide a look forward to a highly productive Space Station era.

  15. Trends in cardiac catheterization laboratories in the United States.

    PubMed

    Sheldon, W C

    2001-05-01

    The Society for Cardiac Angiography and Interventions has periodically published a Directory of Cardiac Catheterization Laboratories in the United States. All known catheterization laboratories are surveyed and certain operational characteristics are queried. These surveys, in 1983, 1987, 1993, 1995 and 1998, have demonstrated a 2.5 fold increase in cardiac catheterization laboratories since 1983, corresponding increases in numbers of physicians that perform procedures, and in the numbers of procedures performed, reflecting advances in cardiovascular medicine and technology. These surveys have also documented the evolution of interventional techniques, and a shift away from film based imaging, to digitally based methods. These data provide a substrate for consideration of national cardiovascular objectives and planning of future resource allocation by cardiovascular physicians and their colleagues. Copyright 2001 Wiley-Liss, Inc.

  16. The Wisconsin State Laboratory of Hygiene and emerging enteric pathogens.

    PubMed

    Warshauer, David; Monson, Tim; Kurzynski, Terry

    2003-01-01

    At the turn of the 20th century, typhoid fever was common in Wisconsin, and was a major impetus for the establishment of the Wisconsin State Laboratory of Hygiene (WSLH) in 1903. By the 1940s, typhoid was virtually eliminated in the United States due to public health measures such as disinfection of drinking water, sewage treatment, pasteurization, and shellfish bed sanitation. However, new food and waterborne pathogens have emerged to take the place of Salmonella Typhi. Infections with non-typhoidal Salmonella strains in the United States have increased almost 10-fold since the 1950s. In the last 20 years, the emergence of foodborne pathogens, such as Escherichia coli O157:H7, Cyclospora cayetanensis, Noroviruses (Norwalk-like viruses), Cryptosporidium parvum, Campylobacter jejuni, Yersinia enterocolitica, and multi-drug-resistant Salmonella, has identified a need for accurate laboratory diagnosis of enteric disease and outbreaks.

  17. KEY COMPARISON: Final report of comparison of the calibrations of hydrometers for liquid density determination between SIM laboratories: SIM.M.D-K4

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar

    2009-01-01

    This SIM comparison on the calibration of high accuracy hydrometers was carried out within fourteen laboratories in the density range from 600 kg/m3 to 1300 kg/m3 in order to evaluate the degree of equivalence among participant laboratories. This key comparison anticipates the planned key comparison CCM.D-K4, and is intended to be linked with CCM.D-K4 when results are available. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  18. Round-robin differential-phase-shift quantum key distribution with a passive decoy state method

    PubMed Central

    Liu, Li; Guo, Fen-Zhuo; Qin, Su-Juan; Wen, Qiao-Yan

    2017-01-01

    Recently, a new type of protocol named Round-robin differential-phase-shift quantum key distribution (RRDPS QKD) was proposed, where the security can be guaranteed without monitoring conventional signal disturbances. The active decoy state method can be used in this protocol to overcome the imperfections of the source. But, it may lead to side channel attacks and break the security of QKD systems. In this paper, we apply the passive decoy state method to the RRDPS QKD protocol. Not only can the more environment disturbance be tolerated, but in addition it can overcome side channel attacks on the sources. Importantly, we derive a new key generation rate formula for our RRDPS protocol using passive decoy states and enhance the key generation rate. We also compare the performance of our RRDPS QKD to that using the active decoy state method and the original RRDPS QKD without any decoy states. From numerical simulations, the performance improvement of the RRDPS QKD by our new method can be seen. PMID:28198808

  19. Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600.

    PubMed

    Miler, Marijana; Nikolac Gabaj, Nora; Dukic, Lora; Simundic, Ana-Maria

    2017-12-27

    The aim of the study was to estimate improvement of work efficiency in the laboratory after implementation of total laboratory automation (TLA) by Abbott Accelerator a3600 in the laboratory with measuring different key performance indicators (KPIs) before and after TLA implementation. The objective was also to recommend steps for defining KPIs in other laboratories. For evaluation of improvement 10 organizational and/or technical KPIs were defined for all phases of laboratory work and measured before (November 2013) and after (from 2015 to 2017) TLA implementation. Out of 10 defined KPIs, 9 were successfully measured and significantly improved. Waiting time for registration of samples in the LIS was significantly reduced from 16 (9-28) to 9 (6-16) minutes after TLA (P < 0.001). After TLA all tests were performed at core biochemistry analyzers which significantly reduced walking distance for sample management (for more than 800 m per worker) and number of tube touches (for almost 50%). Analyzers downtime and engagement time for analyzers maintenance was reduced for 50 h and 28 h per month, respectively. TLA eliminated manual dilution of samples with extreme results with sigma values increment from 3.4 to >6 after TLA. Although median turnaround time TAT for potassium and troponin was higher (for approximately 20 min), number of outliers with TAT >60 min expressed as sigma values were satisfying (>3). Implementation of the TLA improved the most of the processes in our laboratory with 9 out of 10 properly defined and measured KPIs. With proper planning and defining of KPIs, every laboratory could measure changes in daily workflow.

  20. State Legislative Leaders: Keys to Effective Legislation for Children and Families. A Report.

    ERIC Educational Resources Information Center

    State Legislative Leaders Foundation, Centerville, MA.

    In 1993, the State Legislative Leaders Foundation launched a research project, "State Legislative Leaders: Keys To Effective Legislation for Children and Families." This report documents the findings of the project involving 177 of the most influential Republican and Democratic state legislature leaders from all 50 states. For more than…

  1. Optimising the laboratory supply chain: The key to effective laboratory services

    PubMed Central

    Williams, Jason; Smith, Peter; Kuritsky, Joel

    2014-01-01

    Background The Supply Chain Management System (SCMS) is a contract managed under the Partnership for Supply Chain Management (PFSCM) consortium by the United States Agency for International Development (USAID). SCMS procures commodities for programmes supported by the US President’s Emergency Plan for AIDS Relief (PEPFAR). From 2005 to mid-2012, PEPFAR, through SCMS, spent approximately $384 million on non-pharmaceutical commodities. Of this, an estimated $90m was used to purchase flow cytometry technology, largely for flow cytometry platforms and reagents. Objectives The purpose of this paper is to highlight the cost differences between low, medium and high utilisation rates of common CD4 testing instruments that have been procured though PEPFAR funding. Method A scale of costs per test as a function of test volume through the machine was calculated for the two most common CD4 testing machines used in HIV programmes: Becton Dickinson (BD) FACSCount™ and BD FACSCalibur™. Instrument utilisation data collected at the facility level in three selected countries were then used to calculate the onsite cost-per-test experienced in each country. Results Cost analyses indicated that a target of at least 40% utilisation for FACSCount™ and 15% utilisation for FACSCalibur™, respectively, closely approach maximal per-test cost efficiency. The average utilisation rate for CD4 testing instruments varies widely by country, level of laboratory and partner (0% − 68%). Conclusion Our analysis indicates that, because cost-per-test is related inversely to sample throughput, the underutilisation of flow cytometry machines is resulting in an increase in average cost-per-test for many instruments. PMID:29043175

  2. Radar research at The Pennsylvania State University Radar and Communications Laboratory

    NASA Astrophysics Data System (ADS)

    Narayanan, Ram M.

    2017-05-01

    The Radar and Communications Laboratory (RCL) at The Pennsylvania State University is at the forefront of radar technology and is engaged in cutting edge research in all aspects of radar, including modeling and simulation studies of novel radar paradigms, design and development of new types of radar architectures, and extensive field measurements in realistic scenarios. This paper summarizes the research at The Pennsylvania State University's Radar and Communications Laboratory and relevant collaborative research with several groups over the past 15 years in the field of radar and related technologies, including communications, radio frequency identification (RFID), and spectrum sensing.

  3. The laboratory efficiencies initiative: partnership for building a sustainable national public health laboratory system.

    PubMed

    Ridderhof, John C; Moulton, Anthony D; Ned, Renée M; Nicholson, Janet K A; Chu, May C; Becker, Scott J; Blank, Eric C; Breckenridge, Karen J; Waddell, Victor; Brokopp, Charles

    2013-01-01

    Beginning in early 2011, the Centers for Disease Control and Prevention and the Association of Public Health Laboratories launched the Laboratory Efficiencies Initiative (LEI) to help public health laboratories (PHLs) and the nation's entire PHL system achieve and maintain sustainability to continue to conduct vital services in the face of unprecedented financial and other pressures. The LEI focuses on stimulating substantial gains in laboratories' operating efficiency and cost efficiency through the adoption of proven and promising management practices. In its first year, the LEI generated a strategic plan and a number of resources that PHL directors can use toward achieving LEI goals. Additionally, the first year saw the formation of a dynamic community of practitioners committed to implementing the LEI strategic plan in coordination with state and local public health executives, program officials, foundations, and other key partners.

  4. The Laboratory Efficiencies Initiative: Partnership for Building a Sustainable National Public Health Laboratory System

    PubMed Central

    Moulton, Anthony D.; Ned, Renée M.; Nicholson, Janet K.A.; Chu, May C.; Becker, Scott J.; Blank, Eric C.; Breckenridge, Karen J.; Waddell, Victor; Brokopp, Charles

    2013-01-01

    Beginning in early 2011, the Centers for Disease Control and Prevention and the Association of Public Health Laboratories launched the Laboratory Efficiencies Initiative (LEI) to help public health laboratories (PHLs) and the nation's entire PHL system achieve and maintain sustainability to continue to conduct vital services in the face of unprecedented financial and other pressures. The LEI focuses on stimulating substantial gains in laboratories' operating efficiency and cost efficiency through the adoption of proven and promising management practices. In its first year, the LEI generated a strategic plan and a number of resources that PHL directors can use toward achieving LEI goals. Additionally, the first year saw the formation of a dynamic community of practitioners committed to implementing the LEI strategic plan in coordination with state and local public health executives, program officials, foundations, and other key partners. PMID:23997300

  5. Solid-State NMR Spectroscopy for the Physical Chemistry Laboratory

    ERIC Educational Resources Information Center

    Kinnun, Jacob J.; Leftin, Avigdor; Brown, Michael F.

    2013-01-01

    Solid-state nuclear magnetic resonance (NMR) spectroscopy finds growing application to inorganic and organic materials, biological samples, polymers, proteins, and cellular membranes. However, this technique is often neither included in laboratory curricula nor typically covered in undergraduate courses. On the other hand, spectroscopy and…

  6. 10 More States Enact Laws on Vandalizing Animal Laboratories.

    ERIC Educational Resources Information Center

    Blumenstyk, Goldie

    1991-01-01

    Twenty-two states now specifically outlaw such activities as entering a research laboratory without permission, releasing animals, disrupting experiments, and removing documents and photographs related to research. Several expand the definition of criminal activity to include videotaping or photographing facility interiors. Penalties vary by…

  7. Finite-key security analyses on passive decoy-state QKD protocols with different unstable sources.

    PubMed

    Song, Ting-Ting; Qin, Su-Juan; Wen, Qiao-Yan; Wang, Yu-Kun; Jia, Heng-Yue

    2015-10-16

    In quantum communication, passive decoy-state QKD protocols can eliminate many side channels, but the protocols without any finite-key analyses are not suitable for in practice. The finite-key securities of passive decoy-state (PDS) QKD protocols with two different unstable sources, type-II parametric down-convention (PDC) and phase randomized weak coherent pulses (WCPs), are analyzed in our paper. According to the PDS QKD protocols, we establish an optimizing programming respectively and obtain the lower bounds of finite-key rates. Under some reasonable values of quantum setup parameters, the lower bounds of finite-key rates are simulated. The simulation results show that at different transmission distances, the affections of different fluctuations on key rates are different. Moreover, the PDS QKD protocol with an unstable PDC source can resist more intensity fluctuations and more statistical fluctuation.

  8. Finite-key security analyses on passive decoy-state QKD protocols with different unstable sources

    PubMed Central

    Song, Ting-Ting; Qin, Su-Juan; Wen, Qiao-Yan; Wang, Yu-Kun; Jia, Heng-Yue

    2015-01-01

    In quantum communication, passive decoy-state QKD protocols can eliminate many side channels, but the protocols without any finite-key analyses are not suitable for in practice. The finite-key securities of passive decoy-state (PDS) QKD protocols with two different unstable sources, type-II parametric down-convention (PDC) and phase randomized weak coherent pulses (WCPs), are analyzed in our paper. According to the PDS QKD protocols, we establish an optimizing programming respectively and obtain the lower bounds of finite-key rates. Under some reasonable values of quantum setup parameters, the lower bounds of finite-key rates are simulated. The simulation results show that at different transmission distances, the affections of different fluctuations on key rates are different. Moreover, the PDS QKD protocol with an unstable PDC source can resist more intensity fluctuations and more statistical fluctuation. PMID:26471947

  9. 75 FR 48939 - National Superconducting Cyclotron Laboratory of Michigan State University; Notice of Decision on...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-12

    ... DEPARTMENT OF COMMERCE International Trade Administration National Superconducting Cyclotron Laboratory of Michigan State University; Notice of Decision on Applications for Duty-Free Entry of Scientific... Cyclotron Laboratory of Michigan State University. Instrument: Radio Frequency Quadropole Accelerator (RFQ...

  10. Security proof of a three-state quantum-key-distribution protocol without rotational symmetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fung, C.-H.F.; Lo, H.-K.

    2006-10-15

    Standard security proofs of quantum-key-distribution (QKD) protocols often rely on symmetry arguments. In this paper, we prove the security of a three-state protocol that does not possess rotational symmetry. The three-state QKD protocol we consider involves three qubit states, where the first two states |0{sub z}> and |1{sub z}> can contribute to key generation, and the third state |+>=(|0{sub z}>+|1{sub z}>)/{radical}(2) is for channel estimation. This protocol has been proposed and implemented experimentally in some frequency-based QKD systems where the three states can be prepared easily. Thus, by founding on the security of this three-state protocol, we prove that thesemore » QKD schemes are, in fact, unconditionally secure against any attacks allowed by quantum mechanics. The main task in our proof is to upper bound the phase error rate of the qubits given the bit error rates observed. Unconditional security can then be proved not only for the ideal case of a single-photon source and perfect detectors, but also for the realistic case of a phase-randomized weak coherent light source and imperfect threshold detectors. Our result in the phase error rate upper bound is independent of the loss in the channel. Also, we compare the three-state protocol with the Bennett-Brassard 1984 (BB84) protocol. For the single-photon source case, our result proves that the BB84 protocol strictly tolerates a higher quantum bit error rate than the three-state protocol, while for the coherent-source case, the BB84 protocol achieves a higher key generation rate and secure distance than the three-state protocol when a decoy-state method is used.« less

  11. Decoy-state quantum key distribution with polarized photons over 200 km.

    PubMed

    Liu, Yang; Chen, Teng-Yun; Wang, Jian; Cai, Wen-Qi; Wan, Xu; Chen, Luo-Kan; Wang, Jin-Hong; Liu, Shu-Bin; Liang, Hao; Yang, Lin; Peng, Cheng-Zhi; Chen, Kai; Chen, Zeng-Bing; Pan, Jian-Wei

    2010-04-12

    We report an implementation of decoy-state quantum key distribution (QKD) over 200 km optical fiber cable through photon polarization encoding. This is achieved by constructing the whole QKD system operating at 320 MHz repetition rate, and developing high-speed transmitter and receiver modules. A novel and economic way of synchronization method is designed and incorporated into the system, which allows to work at a low frequency of 40kHz and removes the use of highly precise clock. A final key rate of 15 Hz is distributed within the experimental time of 3089 seconds, by using super-conducting single photon detectors. This is longest decoy-state QKD yet demonstrated up to date. It helps to make a significant step towards practical secure communication in long-distance scope.

  12. Laboratory diagnostics of chronic kidney disease in Croatia: state of the art

    PubMed Central

    Honović, Lorena; Matica, Jasminka; Knežević, Branka; Vojak, Sanela Šimić

    2015-01-01

    Introduction Early identification and management of chronic kidney disease (CKD) is highly cost-effective and can reduce the risk of kidney failure progression and cardiovascular disease. In 2014, the Joint Croatian Working Group (JCWG) for laboratory diagnostic of CKD on the behalf of Croatian society of medical biochemistry and laboratory medicine (CSMBLM) and Croatian chamber of medical biochemists (CCMB) conducted a survey across Croatian medical-biochemistry laboratories to assess the current practice in this area of laboratory medicine. The aim of this study was to present the data collected through the survey and to give insight about laboratory diagnostics of chronic kidney disease in Croatia. Materials and methods An invitation to participate in the survey was sent to all Croatian medical-biochemistry laboratories (N = 196). The questionnaire was designed in a form of questions and statements, with possible multiple answers, comprising 24 questions. Results The response rate was 80/196 (40.8%). 39 answers were from primary medical-biochemistry laboratories. 31/78 (0.40) laboratories measure creatinine with non-standardized method (uncompensated Jaffe method). 58/78 (0.74) of laboratories that measure creatinine do not report eGFR values. Similar number of laboratories (58/80, 0.73) do not measure urine albumin or protein. Conclusions There is a large heterogeneity among Croatian laboratories regarding measuring methods, reporting units and reference intervals (cut-off values), both for creatinine and urine albumin or protein. The two key prerequisites for CKD screening, automatic reporting of eGFR and albuminuria or proteinuria assessment, are not implemented nationwide. There is a need for harmonization in laboratory diagnostics of CKD in Croatia. PMID:25672470

  13. Improvement of "Novel Multiparty Quantum Key Agreement Protocol with GHZ States"

    NASA Astrophysics Data System (ADS)

    Gu, Jun; Hwang, Tzonelih

    2017-10-01

    Quantum key agreement (QKA) protocol is a method for negotiating a fair and secure key among mutually untrusted participants. Recently, Xu et al. (Quantum Inf. Process. 13:2587-2594, 2014) proposed a multi-party QKA protocol based on Greenberger-Horne-Zeilinger (GHZ) states. However, this study points out that Xu et al.'s protocol cannot provide the fairness property. That is, the last involved participant in the protocol can manipulate the final shared secret key without being detected by the other participants. Moreover, according to Yu et al.'s research (2015), Xu et al.'s protocol cannot avoid the public discussion attack too. To avoid these weaknesses, an improved QKA protocol is proposed.

  14. Feasibility of continuous-variable quantum key distribution with noisy coherent states

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Usenko, Vladyslav C.; Department of Optics, Palacky University, CZ-772 07 Olomouc; Filip, Radim

    2010-02-15

    We address security of the quantum key distribution scheme based on the noisy modulation of coherent states and investigate how it is robust against noise in the modulation regardless of the particular technical implementation. As the trusted preparation noise is shown to be security breaking even for purely lossy channels, we reveal the essential difference between two types of trusted noise, namely sender-side preparation noise and receiver-side detection noise, the latter being security preserving. We consider the method of sender-side state purification to compensate the preparation noise and show its applicability in the realistic conditions of channel loss, untrusted channelmore » excess noise, and trusted detection noise. We show that purification makes the scheme robust to the preparation noise (i.e., even the arbitrary noisy coherent states can in principle be used for the purpose of quantum key distribution). We also take into account the effect of realistic reconciliation and show that the purification method is still efficient in this case up to a limited value of preparation noise.« less

  15. Part II--Factors Associated with School Nurse Ratios: Key State Informants' Perceptions

    ERIC Educational Resources Information Center

    Maughan, Erin

    2009-01-01

    This paper is the second of a two-part series examining factors influencing school nurse to pupil staffing ratios. The paper reports data from a qualitative study exploring the social and political factors that potentially influence ratios. Interviews were conducted with 30 key state informants from these states. Content analysis of the data…

  16. Gaussian-modulated coherent-state measurement-device-independent quantum key distribution

    NASA Astrophysics Data System (ADS)

    Ma, Xiang-Chun; Sun, Shi-Hai; Jiang, Mu-Sheng; Gui, Ming; Liang, Lin-Mei

    2014-04-01

    Measurement-device-independent quantum key distribution (MDI-QKD), leaving the detection procedure to the third partner and thus being immune to all detector side-channel attacks, is very promising for the construction of high-security quantum information networks. We propose a scheme to implement MDI-QKD, but with continuous variables instead of discrete ones, i.e., with the source of Gaussian-modulated coherent states, based on the principle of continuous-variable entanglement swapping. This protocol not only can be implemented with current telecom components but also has high key rates compared to its discrete counterpart; thus it will be highly compatible with quantum networks.

  17. Composable security proof for continuous-variable quantum key distribution with coherent States.

    PubMed

    Leverrier, Anthony

    2015-02-20

    We give the first composable security proof for continuous-variable quantum key distribution with coherent states against collective attacks. Crucially, in the limit of large blocks the secret key rate converges to the usual value computed from the Holevo bound. Combining our proof with either the de Finetti theorem or the postselection technique then shows the security of the protocol against general attacks, thereby confirming the long-standing conjecture that Gaussian attacks are optimal asymptotically in the composable security framework. We expect that our parameter estimation procedure, which does not rely on any assumption about the quantum state being measured, will find applications elsewhere, for instance, for the reliable quantification of continuous-variable entanglement in finite-size settings.

  18. A State-of-the-Art Experimental Laboratory for Cloud and Cloud-Aerosol Interaction Research

    NASA Technical Reports Server (NTRS)

    Fremaux, Charles M.; Bushnell, Dennis M.

    2011-01-01

    The state of the art for predicting climate changes due to increasing greenhouse gasses in the atmosphere with high accuracy is problematic. Confidence intervals on current long-term predictions (on the order of 100 years) are so large that the ability to make informed decisions with regard to optimum strategies for mitigating both the causes of climate change and its effects is in doubt. There is ample evidence in the literature that large sources of uncertainty in current climate models are various aerosol effects. One approach to furthering discovery as well as modeling, and verification and validation (V&V) for cloud-aerosol interactions is use of a large "cloud chamber" in a complimentary role to in-situ and remote sensing measurement approaches. Reproducing all of the complex interactions is not feasible, but it is suggested that the physics of certain key processes can be established in a laboratory setting so that relevant fluid-dynamic and cloud-aerosol phenomena can be experimentally simulated and studied in a controlled environment. This report presents a high-level argument for significantly improved laboratory capability, and is meant to serve as a starting point for stimulating discussion within the climate science and other interested communities.

  19. Final report on key comparison CCAUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Avison, Janine; Barham, Richard

    2014-01-01

    This document and the accompanying spreadsheets constitute the final report for key comparison CCAUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Twelve national measurement institutes took part in the key comparison and the National Physical Laboratory piloted the project. Two laboratory standard microphones IEC type LS1P were circulated to the participants and results in the form of regular calibration certificates were collected throughout the project. One of the microphones was subsequently deemed to have compromised stability for the purpose of deriving a reference value. Consequently the key comparison reference value (KCRV) has been made based on the weighted mean results for sensitivity level and for sensitivity phase from just one of the microphones. Corresponding degrees of equivalence (DoEs) have also been calculated and are presented. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Report on key comparison COOMET.AUV.A-K5: pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 kHz

    NASA Astrophysics Data System (ADS)

    Dobrowolska, D.; Kosterov, A.

    2016-01-01

    This is the final report for regional key comparison COOMET.AUV.A-K5 on the pressure calibration of laboratory standard microphones in the frequency range from 2 Hz to 10 kHz. Two laboratories—Central Office of Measures (GUM)—the national metrology institute for Poland and the State Enterprise Scientific-Research Institute for Metrology of Measurement and Control Systems (DP NDI Systema)— the designated institute for acoustics in Ukraine took part in this comparison with the GUM as a pilot. One travelling type LS1P microphone was circulated to the participants and results in the form of regular calibration certificates were collected. The results of the DP NDI Systema obtained in this comparison were linked to the CCAUV.A-K5 key comparison through the joint participation of the GUM. The degrees of equivalence were computed for DP NDI Systema with respect to the CCAUV.A-K5 key comparison reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  1. Is laboratory medicine ready for the era of personalized medicine? A survey addressed to laboratory directors of hospitals/academic schools of medicine in Europe.

    PubMed

    Malentacchi, Francesca; Mancini, Irene; Brandslund, Ivan; Vermeersch, Pieter; Schwab, Matthias; Marc, Janja; van Schaik, Ron H N; Siest, Gerard; Theodorsson, Elvar; Pazzagli, Mario; Di Resta, Chiara

    2015-06-01

    Developments in "-omics" are creating a paradigm shift in laboratory medicine leading to personalized medicine. This allows the increase in diagnostics and therapeutics focused on individuals rather than populations. In order to investigate whether laboratory medicine is ready to play a key role in the integration of personalized medicine in routine health care and set the state-of-the-art knowledge about personalized medicine and laboratory medicine in Europe, a questionnaire was constructed under the auspices of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) and the European Society of Pharmacogenomics and Personalised Therapy (ESPT). The answers of the participating laboratory medicine professionals indicate that they are aware that personalized medicine can represent a new and promising health model, and that laboratory medicine should play a key role in supporting the implementation of personalized medicine in the clinical setting. Participants think that the current organization of laboratory medicine needs additional/relevant implementations such as (i) new technological facilities in -omics; (ii) additional training for the current personnel focused on the new methodologies; (iii) incorporation in the laboratory of new competencies in data interpretation and counseling; and (iv) cooperation and collaboration among professionals of different disciplines to integrate information according to a personalized medicine approach.

  2. Faked state attacks on realistic round robin DPS quantum key distribution systems and countermeasure

    NASA Astrophysics Data System (ADS)

    Iwakoshi, T.

    2015-05-01

    In May 2014, a new quantum key distribution protocol named "Round Robin Differential-Phase-Shift Quantum Key Distribution (RR DPS QKD)" was proposed. It has a special feature that the key consumption via privacy amplification is a small constant because RR DPS QKD guarantees its security by information causality, not by information-disturbance trade-off. Therefore, the authors claimed that RR DPS QKD systems does not need to monitor the disturbance by an attacker in the quantum channel. However, this study shows that a modified Faked-State Attack (or so-called bright illumination attack) can hack a RR DPS QKD system almost perfectly if it is implemented with realistic detectors even information-causality guarantees the security of RR DPS QKD protocol. Therefore, this study also proposes a possible Measurement-Device-Independent RR DPS QKD system to avoid the modified Faked-State Attack.

  3. Public health laboratory workforce outreach in Hawai'i: CLIA-focused student internship pilot program at the state laboratories.

    PubMed

    Whelen, A Christian; Kitagawa, Kent

    2013-01-01

    Chronically understaffed public health laboratories depend on a decreasing number of employees who must assume broader responsibilities in order to sustain essential functions for the many clients the laboratories support. Prospective scientists considering a career in public health are often not aware of the requirements associated with working in a laboratory regulated by the Clinical Laboratory Improvement Amendments (CLIA). The purpose of this pilot internship was two-fold; introduce students to operations in a regulated laboratory early enough in their academics so that they could make good career decisions, and evaluate internship methodology as one possible solution to workforce shortages. Four interns were recruited from three different local universities, and were paired with an experienced State Laboratories Division (SLD) staff mentor. Students performed tasks that demonstrated the importance of CLIA regulations for 10-15 hours per week over a 14 week period. Students also attended several directed group sessions on regulatory lab practice and quality systems. Both interns and mentors were surveyed periodically during the semester. Surveys of mentors and interns indicated overall positive experiences. One-on-one pairing of experienced public health professionals and students seems to be a mutually beneficial arrangement. Interns reported that they would participate if the internship was lower paid, unpaid, or for credit only. The internship appeared to be an effective tool to expose students to employment in CLIA-regulated laboratories, and potentially help address public health laboratory staffing shortfalls. Longer term follow up with multiple classes of interns may provide a more informed assessment.

  4. Quantum displacement receiver for M-ary phase-shift-keyed coherent states

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Izumi, Shuro; Takeoka, Masahiro; Fujiwara, Mikio

    2014-12-04

    We propose quantum receivers for 3- and 4-ary phase-shift-keyed (PSK) coherent state signals to overcome the standard quantum limit (SQL). Our receiver, consisting of a displacement operation and on-off detectors with or without feedforward, provides an error probability performance beyond the SQL. We show feedforward operations can tolerate the requirement for the detector specifications.

  5. Four-State Continuous-Variable Quantum Key Distribution with Photon Subtraction

    NASA Astrophysics Data System (ADS)

    Li, Fei; Wang, Yijun; Liao, Qin; Guo, Ying

    2018-06-01

    Four-state continuous-variable quantum key distribution (CVQKD) is one of the discretely modulated CVQKD which generates four nonorthogonal coherent states and exploits the sign of the measured quadrature of each state to encode information rather than uses the quadrature \\hat {x} or \\hat {p} itself. It has been proven that four-state CVQKD is more suitable than Gaussian modulated CVQKD in terms of transmission distance. In this paper, we propose an improved four-state CVQKD using an non-Gaussian operation, photon subtraction. A suitable photon-subtraction operation can be exploited to improve the maximal transmission of CVQKD in point-to-point quantum communication since it provides a method to enhance the performance of entanglement-based (EB) CVQKD. Photon subtraction not only can lengthen the maximal transmission distance by increasing the signal-to-noise rate but also can be easily implemented with existing technologies. Security analysis shows that the proposed scheme can lengthen the maximum transmission distance. Furthermore, by taking finite-size effect into account we obtain a tighter bound of the secure distance, which is more practical than that obtained in the asymptotic limit.

  6. Parameter optimization in biased decoy-state quantum key distribution with both source errors and statistical fluctuations

    NASA Astrophysics Data System (ADS)

    Zhu, Jian-Rong; Li, Jian; Zhang, Chun-Mei; Wang, Qin

    2017-10-01

    The decoy-state method has been widely used in commercial quantum key distribution (QKD) systems. In view of the practical decoy-state QKD with both source errors and statistical fluctuations, we propose a universal model of full parameter optimization in biased decoy-state QKD with phase-randomized sources. Besides, we adopt this model to carry out simulations of two widely used sources: weak coherent source (WCS) and heralded single-photon source (HSPS). Results show that full parameter optimization can significantly improve not only the secure transmission distance but also the final key generation rate. And when taking source errors and statistical fluctuations into account, the performance of decoy-state QKD using HSPS suffered less than that of decoy-state QKD using WCS.

  7. Entangled-coherent-state quantum key distribution with entanglement witnessing

    NASA Astrophysics Data System (ADS)

    Simon, David S.; Jaeger, Gregg; Sergienko, Alexander V.

    2014-01-01

    An entanglement-witness approach to quantum coherent-state key distribution and a system for its practical implementation are described. In this approach, eavesdropping can be detected by a change in sign of either of two witness functions: an entanglement witness S or an eavesdropping witness W. The effects of loss and eavesdropping on system operation are evaluated as a function of distance. Although the eavesdropping witness W does not directly witness entanglement for the system, its behavior remains related to that of the true entanglement witness S. Furthermore, W is easier to implement experimentally than S. W crosses the axis at a finite distance, in a manner reminiscent of entanglement sudden death. The distance at which this occurs changes measurably when an eavesdropper is present. The distance dependence of the two witnesses due to amplitude reduction and due to increased variance resulting from both ordinary propagation losses and possible eavesdropping activity is provided. Finally, the information content and secure key rate of a continuous variable protocol using this witness approach are given.

  8. Laboratory automation: trajectory, technology, and tactics.

    PubMed

    Markin, R S; Whalen, S A

    2000-05-01

    Laboratory automation is in its infancy, following a path parallel to the development of laboratory information systems in the late 1970s and early 1980s. Changes on the horizon in healthcare and clinical laboratory service that affect the delivery of laboratory results include the increasing age of the population in North America, the implementation of the Balanced Budget Act (1997), and the creation of disease management companies. Major technology drivers include outcomes optimization and phenotypically targeted drugs. Constant cost pressures in the clinical laboratory have forced diagnostic manufacturers into less than optimal profitability states. Laboratory automation can be a tool for the improvement of laboratory services and may decrease costs. The key to improvement of laboratory services is implementation of the correct automation technology. The design of this technology should be driven by required functionality. Automation design issues should be centered on the understanding of the laboratory and its relationship to healthcare delivery and the business and operational processes in the clinical laboratory. Automation design philosophy has evolved from a hardware-based approach to a software-based approach. Process control software to support repeat testing, reflex testing, and transportation management, and overall computer-integrated manufacturing approaches to laboratory automation implementation are rapidly expanding areas. It is clear that hardware and software are functionally interdependent and that the interface between the laboratory automation system and the laboratory information system is a key component. The cost-effectiveness of automation solutions suggested by vendors, however, has been difficult to evaluate because the number of automation installations are few and the precision with which operational data have been collected to determine payback is suboptimal. The trend in automation has moved from total laboratory automation to a

  9. The Sanford Science Education Center: Addressing Key Design Challenges in Sharing Complex Science with Diverse Audiences

    ERIC Educational Resources Information Center

    Inverness Research, 2016

    2016-01-01

    In facilities throughout the United States and abroad, communities of scientists share infrastructure, instrumentation, and equipment to conduct scientific research. In these large facilities--laboratories, accelerators, telescope arrays, and research vessels--scientists are researching key questions that have the potential to make a significant…

  10. W-state Analyzer and Multi-party Measurement-device-independent Quantum Key Distribution

    PubMed Central

    Zhu, Changhua; Xu, Feihu; Pei, Changxing

    2015-01-01

    W-state is an important resource for many quantum information processing tasks. In this paper, we for the first time propose a multi-party measurement-device-independent quantum key distribution (MDI-QKD) protocol based on W-state. With linear optics, we design a W-state analyzer in order to distinguish the four-qubit W-state. This analyzer constructs the measurement device for four-party MDI-QKD. Moreover, we derived a complete security proof of the four-party MDI-QKD, and performed a numerical simulation to study its performance. The results show that four-party MDI-QKD is feasible over 150 km standard telecom fiber with off-the-shelf single photon detectors. This work takes an important step towards multi-party quantum communication and a quantum network. PMID:26644289

  11. New Quantum Key Distribution Scheme Based on Random Hybrid Quantum Channel with EPR Pairs and GHZ States

    NASA Astrophysics Data System (ADS)

    Yan, Xing-Yu; Gong, Li-Hua; Chen, Hua-Ying; Zhou, Nan-Run

    2018-05-01

    A theoretical quantum key distribution scheme based on random hybrid quantum channel with EPR pairs and GHZ states is devised. In this scheme, EPR pairs and tripartite GHZ states are exploited to set up random hybrid quantum channel. Only one photon in each entangled state is necessary to run forth and back in the channel. The security of the quantum key distribution scheme is guaranteed by more than one round of eavesdropping check procedures. It is of high capacity since one particle could carry more than two bits of information via quantum dense coding.

  12. Secure key from bound entanglement.

    PubMed

    Horodecki, Karol; Horodecki, Michał; Horodecki, Paweł; Oppenheim, Jonathan

    2005-04-29

    We characterize the set of shared quantum states which contain a cryptographically private key. This allows us to recast the theory of privacy as a paradigm closely related to that used in entanglement manipulation. It is shown that one can distill an arbitrarily secure key from bound entangled states. There are also states that have less distillable private keys than the entanglement cost of the state. In general, the amount of distillable key is bounded from above by the relative entropy of entanglement. Relationships between distillability and distinguishability are found for a class of states which have Bell states correlated to separable hiding states. We also describe a technique for finding states exhibiting irreversibility in entanglement distillation.

  13. Simple scheme to implement decoy-state reference-frame-independent quantum key distribution

    NASA Astrophysics Data System (ADS)

    Zhang, Chunmei; Zhu, Jianrong; Wang, Qin

    2018-06-01

    We propose a simple scheme to implement decoy-state reference-frame-independent quantum key distribution (RFI-QKD), where signal states are prepared in Z, X, and Y bases, decoy states are prepared in X and Y bases, and vacuum states are set to no bases. Different from the original decoy-state RFI-QKD scheme whose decoy states are prepared in Z, X and Y bases, in our scheme decoy states are only prepared in X and Y bases, which avoids the redundancy of decoy states in Z basis, saves the random number consumption, simplifies the encoding device of practical RFI-QKD systems, and makes the most of the finite pulses in a short time. Numerical simulations show that, considering the finite size effect with reasonable number of pulses in practical scenarios, our simple decoy-state RFI-QKD scheme exhibits at least comparable or even better performance than that of the original decoy-state RFI-QKD scheme. Especially, in terms of the resistance to the relative rotation of reference frames, our proposed scheme behaves much better than the original scheme, which has great potential to be adopted in current QKD systems.

  14. Quantum Key Recycling with 8-state encoding (The Quantum One-Time Pad is more interesting than we thought)

    NASA Astrophysics Data System (ADS)

    Škorić, Boris; de Vries, Manon

    Perfect encryption of quantum states using the Quantum One-Time Pad (QOTP) requires two classical key bits per qubit. Almost-perfect encryption, with information-theoretic security, requires only slightly more than 1. We slightly improve lower bounds on the key length. We show that key length n+2log1ɛ suffices to encrypt n qubits in such a way that the cipherstate’s L1-distance from uniformity is upperbounded by ɛ. For a stricter security definition involving the ∞-norm, we prove sufficient key length n+logn+2log1ɛ+1+1nlog1δ+logln21-ɛ, where δ is a small probability of failure. Our proof uses Pauli operators, whereas previous results on the ∞-norm needed Haar measure sampling. We show how to QOTP-encrypt classical plaintext in a nontrivial way: we encode a plaintext bit as the vector ±(1,1,1)/3 on the Bloch sphere. Applying the Pauli encryption operators results in eight possible cipherstates which are equally spread out on the Bloch sphere. This encoding, especially when combined with the half-keylength option of QOTP, has advantages over 4-state and 6-state encoding in applications such as Quantum Key Recycling (QKR) and Unclonable Encryption (UE). We propose a key recycling scheme that is more efficient and can tolerate more noise than a recent scheme by Fehr and Salvail. For 8-state QOTP encryption with pseudorandom keys, we do a statistical analysis of the cipherstate eigenvalues. We present numerics up to nine qubits.

  15. Unconditional security of a three state quantum key distribution protocol.

    PubMed

    Boileau, J-C; Tamaki, K; Batuwantudawe, J; Laflamme, R; Renes, J M

    2005-02-04

    Quantum key distribution (QKD) protocols are cryptographic techniques with security based only on the laws of quantum mechanics. Two prominent QKD schemes are the Bennett-Brassard 1984 and Bennett 1992 protocols that use four and two quantum states, respectively. In 2000, Phoenix et al. proposed a new family of three-state protocols that offers advantages over the previous schemes. Until now, an error rate threshold for security of the symmetric trine spherical code QKD protocol has been shown only for the trivial intercept-resend eavesdropping strategy. In this Letter, we prove the unconditional security of the trine spherical code QKD protocol, demonstrating its security up to a bit error rate of 9.81%. We also discuss how this proof applies to a version of the trine spherical code QKD protocol where the error rate is evaluated from the number of inconclusive events.

  16. To QC or not to QC: the key to a consistent laboratory?

    PubMed

    Lane, Michelle; Mitchell, Megan; Cashman, Kara S; Feil, Deanne; Wakefield, Sarah; Zander-Fox, Deirdre L

    2008-01-01

    A limiting factor in every embryology laboratory is its capacity to grow 'normal' embryos. In human in vitro fertilisation (IVF), there is considerable awareness that the environment of the laboratory itself can alter the quality of the embryos produced and the industry as a whole has moved towards the implementation of auditable quality management systems. Furthermore, in some countries, such as Australia, an established quality management system is mandatory for clinical IVF practice, but such systems are less frequently found in other embryology laboratories. Although the same challenges of supporting consistent and repeatable embryo development are paramount to success in all embryology laboratories, it could be argued that they are more important in a research setting where often the measured outcomes are at an intracellular or molecular level. In the present review, we have outlined the role and importance of quality control and quality assurance systems in any embryo laboratory and have highlighted examples of how simple monitoring can provide consistency and avoid the induction of artefacts, irrespective of the laboratory's purpose, function or species involved.

  17. Analysis of the secrecy of the running key in quantum encryption channels using coherent states of light

    NASA Astrophysics Data System (ADS)

    Nikulin, Vladimir V.; Hughes, David H.; Malowicki, John; Bedi, Vijit

    2015-05-01

    Free-space optical communication channels offer secure links with low probability of interception and detection. Despite their point-to-point topology, additional security features may be required in privacy-critical applications. Encryption can be achieved at the physical layer by using quantized values of photons, which makes exploitation of such quantum communication links extremely difficult. One example of such technology is keyed communication in quantum noise, a novel quantum modulation protocol that offers ultra-secure communication with competitive performance characteristics. Its utilization relies on specific coherent measurements to decrypt the signal. The process of measurements is complicated by the inherent and irreducible quantum noise of coherent states. This problem is different from traditional laser communication with coherent detection; therefore continuous efforts are being made to improve the measurement techniques. Quantum-based encryption systems that use the phase of the signal as the information carrier impose aggressive requirements on the accuracy of the measurements when an unauthorized party attempts intercepting the data stream. Therefore, analysis of the secrecy of the data becomes extremely important. In this paper, we present the results of a study that had a goal of assessment of potential vulnerability of the running key. Basic results of the laboratory measurements are combined with simulation studies and statistical analysis that can be used for both conceptual improvement of the encryption approach and for quantitative comparison of secrecy of different quantum communication protocols.

  18. Improved statistical fluctuation analysis for measurement-device-independent quantum key distribution with four-intensity decoy-state method.

    PubMed

    Mao, Chen-Chen; Zhou, Xing-Yu; Zhu, Jian-Rong; Zhang, Chun-Hui; Zhang, Chun-Mei; Wang, Qin

    2018-05-14

    Recently Zhang et al [ Phys. Rev. A95, 012333 (2017)] developed a new approach to estimate the failure probability for the decoy-state BB84 QKD system when taking finite-size key effect into account, which offers security comparable to Chernoff bound, while results in an improved key rate and transmission distance. Based on Zhang et al's work, now we extend this approach to the case of the measurement-device-independent quantum key distribution (MDI-QKD), and for the first time implement it onto the four-intensity decoy-state MDI-QKD system. Moreover, through utilizing joint constraints and collective error-estimation techniques, we can obviously increase the performance of practical MDI-QKD systems compared with either three- or four-intensity decoy-state MDI-QKD using Chernoff bound analysis, and achieve much higher level security compared with those applying Gaussian approximation analysis.

  19. Laboratory Information Systems.

    PubMed

    Henricks, Walter H

    2015-06-01

    Laboratory information systems (LISs) supply mission-critical capabilities for the vast array of information-processing needs of modern laboratories. LIS architectures include mainframe, client-server, and thin client configurations. The LIS database software manages a laboratory's data. LIS dictionaries are database tables that a laboratory uses to tailor an LIS to the unique needs of that laboratory. Anatomic pathology LIS (APLIS) functions play key roles throughout the pathology workflow, and laboratories rely on LIS management reports to monitor operations. This article describes the structure and functions of APLISs, with emphasis on their roles in laboratory operations and their relevance to pathologists. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Privacy and security of patient data in the pathology laboratory.

    PubMed

    Cucoranu, Ioan C; Parwani, Anil V; West, Andrew J; Romero-Lauro, Gonzalo; Nauman, Kevin; Carter, Alexis B; Balis, Ulysses J; Tuthill, Mark J; Pantanowitz, Liron

    2013-01-01

    Data protection and security are critical components of routine pathology practice because laboratories are legally required to securely store and transmit electronic patient data. With increasing connectivity of information systems, laboratory work-stations, and instruments themselves to the Internet, the demand to continuously protect and secure laboratory information can become a daunting task. This review addresses informatics security issues in the pathology laboratory related to passwords, biometric devices, data encryption, internet security, virtual private networks, firewalls, anti-viral software, and emergency security situations, as well as the potential impact that newer technologies such as mobile devices have on the privacy and security of electronic protected health information (ePHI). In the United States, the Health Insurance Portability and Accountability Act (HIPAA) govern the privacy and protection of medical information and health records. The HIPAA security standards final rule mandate administrative, physical, and technical safeguards to ensure the confidentiality, integrity, and security of ePHI. Importantly, security failures often lead to privacy breaches, invoking the HIPAA privacy rule as well. Therefore, this review also highlights key aspects of HIPAA and its impact on the pathology laboratory in the United States.

  1. Privacy and security of patient data in the pathology laboratory

    PubMed Central

    Cucoranu, Ioan C.; Parwani, Anil V.; West, Andrew J.; Romero-Lauro, Gonzalo; Nauman, Kevin; Carter, Alexis B.; Balis, Ulysses J.; Tuthill, Mark J.; Pantanowitz, Liron

    2013-01-01

    Data protection and security are critical components of routine pathology practice because laboratories are legally required to securely store and transmit electronic patient data. With increasing connectivity of information systems, laboratory work-stations, and instruments themselves to the Internet, the demand to continuously protect and secure laboratory information can become a daunting task. This review addresses informatics security issues in the pathology laboratory related to passwords, biometric devices, data encryption, internet security, virtual private networks, firewalls, anti-viral software, and emergency security situations, as well as the potential impact that newer technologies such as mobile devices have on the privacy and security of electronic protected health information (ePHI). In the United States, the Health Insurance Portability and Accountability Act (HIPAA) govern the privacy and protection of medical information and health records. The HIPAA security standards final rule mandate administrative, physical, and technical safeguards to ensure the confidentiality, integrity, and security of ePHI. Importantly, security failures often lead to privacy breaches, invoking the HIPAA privacy rule as well. Therefore, this review also highlights key aspects of HIPAA and its impact on the pathology laboratory in the United States. PMID:23599904

  2. Employee Spotlight: Baris Key

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Key, Baris

    2014-05-29

    Baris Key, an employee at Argonne National Laboratory, discusses the importance of national lab researchers and how they merge basic science, analyze and process in a way that the industry can benefit from.

  3. Employee Spotlight: Baris Key

    ScienceCinema

    Key, Baris

    2018-04-16

    Baris Key, an employee at Argonne National Laboratory, discusses the importance of national lab researchers and how they merge basic science, analyze and process in a way that the industry can benefit from.

  4. Evaluation of the MyWellness Key accelerometer.

    PubMed

    Herrmann, S D; Hart, T L; Lee, C D; Ainsworth, B E

    2011-02-01

    to examine the concurrent validity of the Technogym MyWellness Key accelerometer against objective and subjective physical activity (PA) measures. randomised, cross-sectional design with two phases. The laboratory phase compared the MyWellness Key with the ActiGraph GT1M and the Yamax SW200 Digiwalker pedometer during graded treadmill walking, increasing speed each minute. The free-living phase compared the MyWellness Key with the ActiGraph, Digiwalker, Bouchard Activity cord (BAR) and Global Physical Activity Questionnaire (GPAQ) for seven continuous days. Data were analysed using Spearman rank-order correlation coefficients for all comparisons. laboratory and free-living phases. sixteen participants randomly stratified from 41 eligible respondents by sex (n=8 men; n=8 women) and PA levels (n=4 low, n=8 middle and n=4 high active). there was a strong association between the MyWellness Key and the ActiGraph accelerometer during controlled graded treadmill walking (r=0.91, p<0.01) and in free-living settings (r=0.73-0.76 for light to vigorous PA, respectively, p<0.01). No associations were observed between the MyWellness Key and the BAR and GPAQ (p>0.05). the MyWellness Key has a high concurrent validity with the ActiGraph accelerometer to detect PA in both controlled laboratory and free-living settings.

  5. Creating Best Practices for the Submission of Actionable Food and Feed Testing Data Generated in State and Local Laboratories.

    PubMed

    Wangsness, Kathryn; Salfinger, Yvonne; Randolph, Robyn; Shea, Shari; Larson, Kirsten

    2017-07-01

    Laboratory accreditation provides a level of standardization in laboratories and confidence in generated food and feed testing results. For some laboratories, ISO/IEC 17025:2005 accreditation may not be fiscally viable, or a requested test method may be out of the scope of the laboratory's accreditation. To assist laboratories for whom accreditation is not feasible, the Association of Public Health Laboratories Data Acceptance Work Group developed a white paper entitled "Best Practices for Submission of Actionable Food and Feed Testing Data Generated in State and Local Laboratories." The basic elements of a quality management system, along with other best practices that state and local food and feed testing laboratories should follow, are included in the white paper. It also covers program-specific requirements that may need to be addressed. Communication with programs and end data users is regarded as essential for establishing the reliability and accuracy of laboratory data. Following these suggested best practices can facilitate the acceptance of laboratory data, which can result in swift regulatory action and the quick removal of contaminated product from the food supply, improving public health nationally.

  6. The American Society for Clinical Pathology's 2014 vacancy survey of medical laboratories in the United States.

    PubMed

    Garcia, Edna; Ali, Asma M; Soles, Ryan M; Lewis, D Grace

    2015-09-01

    To determine the extent and distribution of workforce shortages within the nation's medical laboratories. Historically, the results of this biennial survey have served as a basis for additional research on laboratory recruitment, retention, education, marketing, certification, and advocacy. The 2014 Vacancy Survey was conducted through collaboration between American Society for Clinical Pathology's Institute of Science, Technology, and Policy in Washington, DC, and the Evaluation, Measurement, and Assessment Department and Board of Certification in Chicago, Illinois. Data were collected via an Internet survey that was distributed to individuals who were able to report on staffing and certifications for their laboratories. Data reveal increased overall vacancy rates since 2012 for all departments surveyed except cytology and cytogenetics. Also, results show higher anticipated retirement rates for both staff and supervisors. Overall certification rates are highest among laboratory personnel in cytogenetics, hematology/coagulation, and flow cytometry departments and lowest among phlebotomy, specimen processing, and anatomic pathology. Factors such as retirement and the improving economy are driving the need for more laboratory professionals. Recruitment of qualified laboratory professionals in the workforce and students in laboratory programs will be the key in fulfilling the higher vacancies revealed from the survey results in 2014. Copyright© by the American Society for Clinical Pathology.

  7. Finite key analysis for symmetric attacks in quantum key distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, Tim; Kampermann, Hermann; Kleinmann, Matthias

    2006-10-15

    We introduce a constructive method to calculate the achievable secret key rate for a generic class of quantum key distribution protocols, when only a finite number n of signals is given. Our approach is applicable to all scenarios in which the quantum state shared by Alice and Bob is known. In particular, we consider the six state protocol with symmetric eavesdropping attacks, and show that for a small number of signals, i.e., below n{approx}10{sup 4}, the finite key rate differs significantly from the asymptotic value for n{yields}{infinity}. However, for larger n, a good approximation of the asymptotic value is found.more » We also study secret key rates for protocols using higher-dimensional quantum systems.« less

  8. Surveillance for laboratory-confirmed sporadic cases of cyclosporiasis--United States, 1997-2008.

    PubMed

    Hall, Rebecca L; Jones, Jeffrey L; Herwaldt, Barbara L

    2011-04-08

    Cyclosporiasis is an enteric disease caused by the parasite Cyclospora cayetanensis. Cyclosporiasis is reported most commonly in tropical and subtropical regions. In the United States, outbreaks of cyclosporiasis associated with various types of imported fresh produce have been documented and described since the mid-1990s. No molecular tools are available for linking C. cayetanensis cases. National data regarding laboratory-confirmed sporadic cases (i.e., cases not linked to documented outbreaks) have not been summarized previously. This summary includes laboratory-confirmed sporadic cases that occurred during 1997-2008 and were reported to CDC by 2009. In January 1999, cyclosporiasis became a nationally notifiable disease, and, as of 2008, it was a reportable condition in 37 states, New York City (NYC), and the District of Columbia. For 1997-2008, CDC was notified of laboratory-confirmed cases via two active surveillance systems (the Cyclospora Sentinel Surveillance Network and the Foodborne Diseases Active Surveillance Network), two passive systems (the National Notifiable Diseases Surveillance System and the Public Health Laboratory Information System), and informal mechanisms (e.g., electronic mail). CDC was notified of 1,110 laboratory-confirmed sporadic cases of cyclosporiasis that occurred during 1997-2008. The overall population-adjusted incidence rates ranged from a low of 0.01 cases per 100,000 persons in 1997 to a high of 0.07 in 2002. Of the 1,110 cases, 849 (76.5%) were reported by seven states: 498 (44.9%) occurred in residents of Florida (228 cases), NYC (200 cases), and elsewhere in New York state (70 cases); and >50 cases were reported by each of five other states (Connecticut, Georgia, Massachusetts, New Jersey, and Pennsylvania). Overall, the case-patients' median age was 44 years (range: 3 months-96 years); 50.5% were female, 47.2% were male, and the sex was unknown for 2.3%. A total of 372 case-patients (33.5%) had a documented history of

  9. "State of the Nation": A Discussion of Some of the Project's Key Findings

    ERIC Educational Resources Information Center

    Earley, Peter

    2010-01-01

    This paper considers several of the key findings of the State of the Nation research. Specific reference is made to three areas--impact evaluation, strategic leadership of professional development, and barriers and constraints to effective CPD practice--which are considered with reference to findings from the other TDA-funded projects conducted at…

  10. A Secure Key Distribution System of Quantum Cryptography Based on the Coherent State

    NASA Technical Reports Server (NTRS)

    Guo, Guang-Can; Zhang, Xiao-Yu

    1996-01-01

    The cryptographic communication has a lot of important applications, particularly in the magnificent prospects of private communication. As one knows, the security of cryptographic channel depends crucially on the secrecy of the key. The Vernam cipher is the only cipher system which has guaranteed security. In that system the key must be as long as the message and most be used only once. Quantum cryptography is a method whereby key secrecy can be guaranteed by a physical law. So it is impossible, even in principle, to eavesdrop on such channels. Quantum cryptography has been developed in recent years. Up to now, many schemes of quantum cryptography have been proposed. Now one of the main problems in this field is how to increase transmission distance. In order to use quantum nature of light, up to now proposed schemes all use very dim light pulses. The average photon number is about 0.1. Because of the loss of the optical fiber, it is difficult for the quantum cryptography based on one photon level or on dim light to realize quantum key-distribution over long distance. A quantum key distribution based on coherent state is introduced in this paper. Here we discuss the feasibility and security of this scheme.

  11. Mont Terri Underground Rock Laboratory, Switzerland-Research Program And Key Results

    NASA Astrophysics Data System (ADS)

    Nussbaum, C. O.; Bossart, P. J.

    2012-12-01

    Argillaceous formations generally act as aquitards because of their low hydraulic conductivities. This property, together with the large retention capacity of clays for cationic contaminants and the potential for self-sealing, has brought clay formations into focus as potential host rocks for the geological disposal of radioactive waste. Excavated in the Opalinus Clay formation, the Mont Terri underground rock laboratory in the Jura Mountains of NW Switzerland is an important international test site for researching clay formations. Research is carried out in the underground facility, which is located adjacent to the security gallery of the Mont Terri motorway tunnel. Fifteen partners from European countries, USA, Canada and Japan participate in the project. The objectives of the research program are to analyze the hydrogeological, geochemical and rock mechanical properties of the Opalinus Clay, to determine the changes induced by the excavation of galleries and by heating of the rock formation, to test sealing and container emplacement techniques and to evaluate and improve suitable investigation techniques. For the safety of deep geological disposal, it is of key importance to understand the processes occurring in the undisturbed argillaceous environment, as well as the processes in a disturbed system, during the operation of the repository. The objectives are related to: 1. Understanding processes and mechanisms in undisturbed clays and 2. Experiments related to repository-induced perturbations. Experiments of the first group are dedicated to: i) Improvement of drilling and excavation technologies and sampling methods; ii) Estimation of hydrogeological, rock mechanical and geochemical parameters of the undisturbed Opalinus Clay. Upscaling of parameters from laboratory to in situ scale; iii) Geochemistry of porewater and natural gases; evolution of porewater over time scales; iv) Assessment of long-term hydraulic transients associated with erosion and thermal

  12. Economic Impact of Pacific Northwest National Laboratory on the State of Washington in Fiscal Year 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Michael J.; Niemeyer, Jackie M.

    Pacific Northwest National Laboratory (PNNL) is a large economic entity, with $1.06 billion in annual funding, $936 million in total spending, and 4,344 employees in fiscal year (FY) 2013. Four thousand, one hundred and one (4,101) employees live in Washington State. The Laboratory directly and indirectly supports almost $1.31 billion in economic output, 6,802 jobs, and $514 million in Washington State wage income from current operations. The state also gains more than $1.21 billion in output, more than 6,400 jobs, and $459 million in income through closely related economic activities, such as visitors, health care spending, spending by resident retirees,more » and spinoff companies. PNNL affects Washington’s economy through commonly recognized economic channels, including spending on payrolls and other goods and services that support Laboratory operations. Less-commonly recognized channels also have their own impacts and include company-supported spending on health care for its staff members and retirees, spending of its resident retirees, Laboratory visitor spending, and the economic activities in a growing constellation of “spinoff” companies founded on PNNL research, technology, and managerial expertise. PNNL also has a significant impact on science and technology education and community nonprofit organizations. PNNL is an active participant in the future scientific enterprise in Washington with the state’s K-12 schools, colleges, and universities. The Laboratory sends staff members to the classroom and brings hundreds of students to the PNNL campus to help train the next generation of scientists, engineers, mathematicians, and technicians. This investment in human capital, though difficult to measure in terms of current dollars of economic output, is among the important lasting legacies of the Laboratory. Finally, PNNL contributes to the local community with millions of dollars’ worth of cash and in-kind corporate and staff contributions, all of

  13. Trustworthiness of detectors in quantum key distribution with untrusted detectors

    DOE PAGES

    Qi, Bing

    2015-02-25

    Measurement-device-independent quantum key distribution (MDI-QKD) protocol has been demonstrated as a viable solution to detector side-channel attacks. One of the main advantages of MDI-QKD is that the security can be proved without making any assumptions about how the measurement device works. The price to pay is the relatively low secure key rate comparing with conventional quantum key distribution (QKD), such as the decoy-state BB84 protocol. Recently a new QKD protocol, aiming at bridging the strong security of MDI-QKD with the high e ciency of conventional QKD, has been proposed. In this protocol, the legitimate receiver employs a trusted linear opticsmore » network to encode information on photons received from an insecure quantum channel, and then performs a Bell state measurement (BSM) using untrusted detectors. One crucial assumption made in most of these studies is that the untrusted BSM located inside the receiver's laboratory cannot send any unwanted information to the outside. Here in this paper, we show that if the BSM is completely untrusted, a simple scheme would allow the BSM to send information to the outside. Combined with Trojan horse attacks, this scheme could allow Eve to gain information of the quantum key without being detected. Ultimately, to prevent the above attack, either countermeasures to Trojan horse attacks or some trustworthiness to the "untrusted" BSM device is required.« less

  14. Updating the immunology curriculum in clinical laboratory science.

    PubMed

    Stevens, C D

    2000-01-01

    To determine essential content areas of immunology/serology courses at the clinical laboratory technician (CLT) and clinical laboratory scientist (CLS) levels. A questionnaire was designed which listed all major topics in immunology and serology. Participants were asked to place a check beside each topic covered. For an additional list of serological and immunological laboratory testing, participants were asked to indicate if each test was performed in either the didactic or clinical setting, or not performed at all. A national survey of 593 NAACLS approved CLT and CLS programs was conducted by mail under the auspices of ASCLS. Responses were obtained from 158 programs. Respondents from all across the United States included 60 CLT programs, 48 hospital-based CLS programs, 45 university-based CLS programs, and 5 university-based combined CLT and CLS programs. The survey was designed to enumerate major topics included in immunology and serology courses by a majority of participants at two distinct educational levels, CLT and CLS. Laboratory testing routinely performed in student laboratories as well as in the clinical setting was also determined for these two levels of practitioners. Certain key topics were common to most immunology and serology courses. There were some notable differences in the depth of courses at the CLT and CLS levels. Laboratory testing associated with these courses also differed at the two levels. Testing requiring more detailed interpretation, such as antinuclear antibody patterns (ANAs), was mainly performed by CLS students only. There are certain key topics as well as specific laboratory tests that should be included in immunology/serology courses at each of the two different educational levels to best prepare students for the workplace. Educators can use this information as a guide to plan a curriculum for such courses.

  15. Part II--Factors associated with school nurse ratios: key state informants' perceptions.

    PubMed

    Maughan, Erin

    2009-08-01

    This paper is the second of a two-part series examining factors influencing school nurse to pupil staffing ratios. The paper reports data from a qualitative study exploring the social and political factors that potentially influence ratios. Interviews were conducted with 30 key state informants from these states. Content analysis of the data identified common themes. Positive factors reported to influence ratios included: the approach taken to effect change, value placed upon school nurses, local support (from both educators and parents) and community buy-in, fear of litigation, and dynamic leadership. Barriers to improving ratios included: lack of funding and misunderstanding of the role of the school nurse. Philosophical beliefs and state geography were "swing" factors that influenced staffing positively or negatively. This study adds to our knowledge of the factors influencing staffing and highlights important social and political factors that school nurses can target to improve nurse to pupil ratios.

  16. 78 FR 33221 - Special Local Regulation; Annual Swim Around Key West, Atlantic Ocean and Gulf of Mexico; Key...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-04

    ... Fort Zach State Park, North through Key West Harbor, East through Flemming Cut, South on Cow Key... State Park, North through Key West Harbor, East through Flemming Cut, South on Cow Key Channel and West...

  17. United States Air Force Summer Research Program -- 1992 High School Apprenticeship Program (HSAP) Reports. Volume 13. Phillips Laboratory

    DTIC Science & Technology

    1992-01-01

    Research Program Phillips Laboratory I4oJ A*6Iv4 Sponsored by: Air Force Office of Scientific Research Kirtland Air ...UNITED STATES AIR FORCE SUMMER RESEARCH PROGki"A -- 1992 HIGH SCHOOL APPRENTICESHIP PROGRAM (HSAP) REPORTS VOLUME 13 (t PHILLIPS LABORATORY . RESEARCH ...Arlington High School Final Report for: Summer Research Program Geophysics Directorate Phillips Laboratory

  18. Proof-of-principle test of coherent-state continuous variable quantum key distribution through turbulent atmosphere (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Derkach, Ivan D.; Peuntinger, Christian; Ruppert, László; Heim, Bettina; Gunthner, Kevin; Usenko, Vladyslav C.; Elser, Dominique; Marquardt, Christoph; Filip, Radim; Leuchs, Gerd

    2016-10-01

    Continuous-variable quantum key distribution is a practical application of quantum information theory that is aimed at generation of secret cryptographic key between two remote trusted parties and that uses multi-photon quantum states as carriers of key bits. Remote parties share the secret key via a quantum channel, that presumably is under control of of an eavesdropper, and which properties must be taken into account in the security analysis. Well-studied fiber-optical quantum channels commonly possess stable transmittance and low noise levels, while free-space channels represent a simpler, less demanding and more flexible alternative, but suffer from atmospheric effects such as turbulence that in particular causes a non-uniform transmittance distribution referred to as fading. Nonetheless free-space channels, providing an unobstructed line-of-sight, are more apt for short, mid-range and potentially long-range (using satellites) communication and will play an important role in the future development and implementation of QKD networks. It was previously theoretically shown that coherent-state CV QKD should be in principle possible to implement over a free-space fading channel, but strong transmittance fluctuations result in the significant modulation-dependent channel excess noise. In this regime the post-selection of highly transmitting sub-channels may be needed, which can even restore the security of the protocol in the strongly turbulent channels. We now report the first proof-of-principle experimental test of coherent state CV QKD protocol using different levels Gaussian modulation over a mid-range (1.6-kilometer long) free-space atmospheric quantum channel. The transmittance of the link was characterized using intensity measurements for the reference but channel estimation using the modulated coherent states was also studied. We consider security against Gaussian collective attacks, that were shown to be optimal against CV QKD protocols . We assumed a

  19. [Revolution of the health care delivery system and its impacts on laboratory testing in the United States].

    PubMed

    Takemura, Y; Ishibashi, M

    2000-02-01

    Failure to slow the exponential growth of total health care expenditures in the United States through the government policies resulted in a rapid and progressive penetration of managed care organizations(MCOs) in the early 1990s. Diagnostic testing is viewed as a "commodity" rather than a medical service under the managed care environment. Traditional hospital-based laboratories are placed in a downward spiral with the advent of managed care era. A massive reduction of in-house testing resulted from shorter lengths of patients' hospital stay and a marked decrease in admission under the dominance of managed care urges them to develop strategies for restoring tests deprived by the managed care-associated new businesses: consolidation and networking, participation in the outreach-testing market, and point-of-care/satellite laboratory testing in non-traditional, ambulatory settings are major strategies for survival of hospital laboratories. A number of physicians' office laboratories(POLs) have been closed owing to regulatory restrictions imposed by the Clinical Laboratory Improvement Amendments of 1988(CLIA '88), and to the expanded penetration of MCOs which limit reimbursement to a very few in-house procedures. It seems likely that POLs and hospital laboratories continue to reduce test volumes, while commercial reference laboratories(CRLs) gain more tests through contracting with MCOs. In the current stream of managed care dominance in the United States, clinical laboratories are changing their basic operation focus and mission in response to the aggressively changing landscape. Traditional laboratories which are unwilling to adapt themselves to the new environment will not survive in this country.

  20. Work Keys USA.

    ERIC Educational Resources Information Center

    Work Keys USA, 1998

    1998-01-01

    "Work Keys" is a comprehensive program for assessing and teaching workplace skills. This serial "special issue" features 18 first-hand reports on Work Keys projects in action in states across North America. They show how the Work Keys is helping businesses and educators solve the challenge of building a world-class work force.…

  1. Quality in the molecular microbiology laboratory.

    PubMed

    Wallace, Paul S; MacKay, William G

    2013-01-01

    In the clinical microbiology laboratory advances in nucleic acid detection, quantification, and sequence analysis have led to considerable improvements in the diagnosis, management, and monitoring of infectious diseases. Molecular diagnostic methods are routinely used to make clinical decisions based on when and how to treat a patient as well as monitor the effectiveness of a therapeutic regime and identify any potential drug resistant strains that may impact on the long term patient treatment program. Therefore, confidence in the reliability of the result provided by the laboratory service to the clinician is essential for patient treatment. Hence, suitable quality assurance and quality control measures are important to ensure that the laboratory methods and service meet the necessary regulatory requirements both at the national and international level. In essence, the modern clinical microbiology laboratory ensures the appropriateness of its services through a quality management system that monitors all aspects of the laboratory service pre- and post-analytical-from patient sample receipt to reporting of results, from checking and upholding staff competency within the laboratory to identifying areas for quality improvements within the service offered. For most European based clinical microbiology laboratories this means following the common International Standard Organization (ISO9001) framework and ISO15189 which sets out the quality management requirements for the medical laboratory (BS EN ISO 15189 (2003) Medical laboratories-particular requirements for quality and competence. British Standards Institute, Bristol, UK). In the United States clinical laboratories performing human diagnostic tests are regulated by the Centers for Medicare and Medicaid Services (CMS) following the requirements within the Clinical Laboratory Improvement Amendments document 1988 (CLIA-88). This chapter focuses on the key quality assurance and quality control requirements within the

  2. Economic Impact of Pacific Northwest National Laboratory on the State of Washington in Fiscal Year 2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Michael J.; Niemeyer, Jackie M.

    PNNL is a large economic entity with a total of 4,308 employees, $939 million (M) in total funding, and $1.02 billion (B) in total spending during FY 2014. The number of employees that live in Washington State is 4,026 or 93 percent of the Laboratory staff. he Laboratory directly and indirectly supported $1.45 billion in economic output, 6,832 jobs, and $517 million in Washington State wage income from current operations. The state also gained more than $1.19 billion in output, over 6,200 jobs, and $444 million in income through closely related economic activities such as visitors, health care spending, spendingmore » by resident retirees, and spinoff companies. PNNL affects Washington’s economy through commonly recognized economic channels, including spending on payrolls and other goods and services that support Laboratory operations. Less commonly recognized channels also have their own impacts and include company-supported spending on health care for its staff members and retirees, spending of its resident retirees, Laboratory visitor spending, and the economic activities in a growing constellation of “spinoff” companies founded on PNNL research, technology, and managerial expertise. PNNL also has a significant impact on science and technology education and community not-for-profit organizations. PNNL is an active participant in the future scientific enterprise in Washington with the state’s K-12 schools, colleges, and universities. The Laboratory sends staff members to the classroom and brings hundreds of students to the PNNL campus to help train the next generation of scientists, engineers, mathematicians, and technicians. This investment in human capital, though difficult to measure in terms of current dollars of economic output, is among the important lasting legacies of the Laboratory. Finally, PNNL contributes to the local community with millions of dollars’ worth of cash and in-kind corporate and staff contributions, all of which strengthen

  3. Laboratory space physics: Investigating the physics of space plasmas in the laboratory

    NASA Astrophysics Data System (ADS)

    Howes, Gregory G.

    2018-05-01

    Laboratory experiments provide a valuable complement to explore the fundamental physics of space plasmas without the limitations inherent to spacecraft measurements. Specifically, experiments overcome the restriction that spacecraft measurements are made at only one (or a few) points in space, enable greater control of the plasma conditions and applied perturbations, can be reproducible, and are orders of magnitude less expensive than launching spacecraft. Here, I highlight key open questions about the physics of space plasmas and identify the aspects of these problems that can potentially be tackled in laboratory experiments. Several past successes in laboratory space physics provide concrete examples of how complementary experiments can contribute to our understanding of physical processes at play in the solar corona, solar wind, planetary magnetospheres, and the outer boundary of the heliosphere. I present developments on the horizon of laboratory space physics, identifying velocity space as a key new frontier, highlighting new and enhanced experimental facilities, and showcasing anticipated developments to produce improved diagnostics and innovative analysis methods. A strategy for future laboratory space physics investigations will be outlined, with explicit connections to specific fundamental plasma phenomena of interest.

  4. Current Guidelines, Common Clinical Pitfalls, and Future Directions for Laboratory Diagnosis of Lyme Disease, United States.

    PubMed

    Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul; Schriefer, Martin

    2016-07-01

    In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%-40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%-100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics.

  5. The challenge of spin–orbit-tuned ground states in iridates: a key issues review

    NASA Astrophysics Data System (ADS)

    Cao, Gang; Schlottmann, Pedro

    2018-04-01

    Effects of spin–orbit interactions in condensed matter are an important and rapidly evolving topic. Strong competition between spin–orbit, on-site Coulomb and crystalline electric field interactions in iridates drives exotic quantum states that are unique to this group of materials. In particular, the ‘J eff  =  ½’ Mott state served as an early signal that the combined effect of strong spin–orbit and Coulomb interactions in iridates has unique, intriguing consequences. In this Key Issues Review, we survey some current experimental studies of iridates. In essence, these materials tend to defy conventional wisdom: absence of conventional correlations between magnetic and insulating states, avoidance of metallization at high pressures, ‘S-shaped’ I–V characteristic, emergence of an odd-parity hidden order, etc. It is particularly intriguing that there exist conspicuous discrepancies between current experimental results and theoretical proposals that address superconducting, topological and quantum spin liquid phases. This class of materials, in which the lattice degrees of freedom play a critical role seldom seen in other materials, evidently presents some profound intellectual challenges that call for more investigations both experimentally and theoretically. Physical properties unique to these materials may help unlock a world of possibilities for functional materials and devices. We emphasize that, given the rapidly developing nature of this field, this Key Issues Review is by no means an exhaustive report of the current state of experimental studies of iridates.

  6. [Depressive-like state and sleep in laboratory mice].

    PubMed

    Strekalova, T V; Cespuglio, R; Koval'zon, V M

    2008-01-01

    In order to induce the state of anhedonia, a key symptom of depression, mice were subjected to a one-month stress procedure comprised of various stressors. Anhedonic state was defined by a reduction of preference for sucrose solution over tap water. Conventional cortical and neck-muscle electrodes were implanted to control and stressed animals under chloral-hydrate anesthesia. After a two-week recovery and habituation period, mice from chronically stressed group were re-subjected to five-day stress, and the anhedonic state was verified. As not all the stressed mice displayed a decrease in sucrose preference, animals were divided in two groups: stressed-non-anhedonic and stressed-anhedonic animals. Seven-day continuous polygraphic recording was carried out in animals from both stressed groups and the control group in recording chambers under conditions of 12/12-hour light/dark schedule. The anhedonic mice demonstrated a significant advanced shift in circadian distribution of paradoxical sleep and increased amount of paradoxical sleep during the light period. In the course of the dark period, the anhedonic group showed a slight but significant decrease in total amount of slow-wave sleep as compared to the non-anhedonic and control groups. The results suggest that the changes in sleep structure documented in the model of anhedonia are similar to those described for human depression.

  7. Laboratory Astrophysics as Key to Understanding the Universe

    NASA Astrophysics Data System (ADS)

    van Dishoeck, Ewine F.

    2012-05-01

    Modern astrophysics is blessed with an increasing amount of high quality observational data on astronomical sources, ranging from our own solar system to the edge of the Universe and from the lowest temperature clouds to the highest energy cosmic rays. Spectra containing thousands of features of atoms, molecules, ice and dust are routinely obtained for stars, planets, comets, the ISM andstar-forming regions, and in the near future even for the most distant galaxies. Realistic models of exo-planetary atmospheres require information on billions of lines. Theories of jets from young stars benefit from plasma experiments to benchmark them. Stellar evolution theories and cosmology rely heavily on accurate rates for nuclear fusion reactions. The first stars could not have formed without the simplest chemical reactions taking place in primordial clouds. Particle physics is at the heart of finding candidates for the mysterious dark matter. There is no doubt that laboratory astrophysics, which includes theoretical calculations, remains at the foundation of the interpretation of observations and truly 'makes astronomy tick'. In this talk, several recent developments in determining these fundamental data will be presented which have resulted in significant advances in our understanding of astrophysical environments. Often, a comparatively minor investment in basic studies can greatly enhance the scientific return from missions. Examples will be taken from each of the 6 themes of the new Laboratory Astrophysics dvision of the AAS (www.aas.org/labastro/lawg_charter.php): atomic, molecular, solid matter, plasma, nuclear, and particle physics. Special attention will be given to recent results from infrared and millimeter facilities, including Herschel and ALMA, which reveal rich spectra of water and organic molecules in star- and planet forming zones. Their interpretation is greatly added by the application of ultra-high vacuum surface science techniques to astrophysical problems.

  8. Long-distance continuous-variable quantum key distribution using non-Gaussian state-discrimination detection

    NASA Astrophysics Data System (ADS)

    Liao, Qin; Guo, Ying; Huang, Duan; Huang, Peng; Zeng, Guihua

    2018-02-01

    We propose a long-distance continuous-variable quantum key distribution (CVQKD) with a four-state protocol using non-Gaussian state-discrimination detection. A photon subtraction operation, which is deployed at the transmitter, is used for splitting the signal required for generating the non-Gaussian operation to lengthen the maximum transmission distance of the CVQKD. Whereby an improved state-discrimination detector, which can be deemed as an optimized quantum measurement that allows the discrimination of nonorthogonal coherent states beating the standard quantum limit, is applied at the receiver to codetermine the measurement result with the conventional coherent detector. By tactfully exploiting the multiplexing technique, the resulting signals can be simultaneously transmitted through an untrusted quantum channel, and subsequently sent to the state-discrimination detector and coherent detector, respectively. Security analysis shows that the proposed scheme can lengthen the maximum transmission distance up to hundreds of kilometers. Furthermore, by taking the finite-size effect and composable security into account we obtain the tightest bound of the secure distance, which is more practical than that obtained in the asymptotic limit.

  9. Clinical Microbiology Laboratories' Adoption of Culture-Independent Diagnostic Tests Is a Threat to Foodborne-Disease Surveillance in the United States.

    PubMed

    Shea, Shari; Kubota, Kristy A; Maguire, Hugh; Gladbach, Stephen; Woron, Amy; Atkinson-Dunn, Robyn; Couturier, Marc Roger; Miller, Melissa B

    2017-01-01

    INTRODUCTIONIn November 2015, the Centers for Disease Control and Prevention (CDC) sent a letter to state and territorial epidemiologists, state and territorial public health laboratory directors, and state and territorial health officials. In this letter, culture-independent diagnostic tests (CIDTs) for detection of enteric pathogens were characterized as "a serious and current threat to public health surveillance, particularly for Shiga toxin-producing Escherichia coli (STEC) and Salmonella" The document says CDC and its public health partners are approaching this issue, in part, by "reviewing regulatory authority in public health agencies to require culture isolates or specimen submission if CIDTs are used." Large-scale foodborne outbreaks are a continuing threat to public health, and tracking these outbreaks is an important tool in shortening them and developing strategies to prevent them. It is clear that the use of CIDTs for enteric pathogen detection, including both antigen detection and multiplex nucleic acid amplification techniques, is becoming more widespread. Furthermore, some clinical microbiology laboratories will resist the mandate to require submission of culture isolates, since it will likely not improve patient outcomes but may add significant costs. Specimen submission would be less expensive and time-consuming for clinical laboratories; however, this approach would be burdensome for public health laboratories, since those laboratories would need to perform culture isolation prior to typing. Shari Shea and Kristy Kubota from the Association of Public Health Laboratories, along with state public health laboratory officials from Colorado, Missouri, Tennessee, and Utah, will explain the public health laboratories' perspective on why having access to isolates of enteric pathogens is essential for public health surveillance, detection, and tracking of outbreaks and offer potential workable solutions which will allow them to do this. Marc Couturier of

  10. Making Stuff Outreach at the Ames Laboratory and Iowa State University

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ament, Katherine; Karsjen, Steven; Leshem-Ackerman, Adah

    The U. S. Department of Energy's Ames Laboratory in Ames, Iowa was a coalition partner for outreach activities connected with NOVA's Making Stuff television series on PBS. Volunteers affiliated with the Ames Laboratory and Iowa State University, with backgrounds in materials science, took part in activities including a science-themed Family Night at a local mall, Science Cafes at the Science Center of Iowa, teacher workshops, demonstrations at science nights in elementary and middle schools, and various other events. We describe a selection of the activities and present a summary of their outcomes and extent of their impact on Ames, Desmore » Moines and the surrounding communities in Iowa. In Part 2, results of a volunteer attitude survey are presented, which shed some light on the volunteer experience and show how the volunteers participation in outreach activities has affected their views of materials education.« less

  11. Critical laboratory values in hemostasis: toward consensus.

    PubMed

    Lippi, Giuseppe; Adcock, Dorothy; Simundic, Ana-Maria; Tripodi, Armando; Favaloro, Emmanuel J

    2017-09-01

    The term "critical values" can be defined to entail laboratory test results that significantly lie outside the normal (reference) range and necessitate immediate reporting to safeguard patient health, as well as those displaying a highly and clinically significant variation compared to previous data. The identification and effective communication of "highly pathological" values has engaged the minds of many clinicians, health care and laboratory professionals for decades, since these activities are vital to good laboratory practice. This is especially true in hemostasis, where a timely and efficient communication of critical values strongly impacts patient management. Due to the heterogeneity of available data, this paper is hence aimed to analyze the state of the art and provide an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis, thus providing a basic document for future consultation that assists laboratory professionals and clinicians alike. KEY MESSAGES Critical values are laboratory test results significantly lying outside the normal (reference) range and necessitating immediate reporting to safeguard patient health. A broad heterogeneity exists about critical values in hemostasis worldwide. We provide here an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis.

  12. Establishment of National Laboratory Standards in Public and Private Hospital Laboratories

    PubMed Central

    ANJARANI, Soghra; SAFADEL, Nooshafarin; DAHIM, Parisa; AMINI, Rana; MAHDAVI, Saeed; MIRAB SAMIEE, Siamak

    2013-01-01

    In September 2007 national standard manual was finalized and officially announced as the minimal quality requirements for all medical laboratories in the country. Apart from auditing laboratories, Reference Health Laboratory has performed benchmarking auditing of medical laboratory network (surveys) in provinces. 12th benchmarks performed in Tehran and Alborz provinces, Iran in 2010 in three stages. We tried to compare different processes, their quality and accordance with national standard measures between public and private hospital laboratories. The assessment tool was a standardized checklist consists of 164 questions. Analyzing process show although in most cases implementing the standard requirements are more prominent in private laboratories, there is still a long way to complete fulfillment of requirements, and it takes a lot of effort. Differences between laboratories in public and private sectors especially in laboratory personnel and management process are significant. Probably lack of motivation, plays a key role in obtaining less desirable results in laboratories in public sectors. PMID:23514840

  13. [Application of laboratory information system in the management of the key indicators of quality inspection].

    PubMed

    Guo, Ye; Chen, Qian; Wu, Wei; Cui, Wei

    2015-03-31

    To establish a system of monitoring the key indicator of quality for inspection (KIQI) on a laboratory information system (LIS), and to have a better management of KIQI. Clinical sample made in PUMCH were collected during the whole of 2014. Next, interactive input program were designed to accomplish data collecting of the disqualification rate of samples, the mistake rate of samples and the occasions of losing samples, etc. Then, a series moment of sample collection, laboratory sample arrived, sample test, sample check, response to critical value, namely, trajectory information left on LIS were recorded and the qualification rate of TAT, the notification rate of endangering result were calculated. Finally, the information about quality control were collected to build an internal quality control database and the KIQI, such as the out-of-control rate of quality control and the total error of test items were monitored. The inspection of the sample management shows the disqualification rates in 2014 were all below the target, but the rates in January and February were a little high and the rates of four wards were above 2%. The mistake rates of samples was 0.47 cases/10 000 cases, attaining the target (< 2 cases/10 000 cases). Also, there was no occasion of losing samples in 2014, attaining the target too. The inspection of laboratory reports shows the qualification rates of TAT was within the acceptable range (> 95%), however the rates of blood routine in November (94.75%) was out of range. We have solved the problem by optimizing the processes. The notification rate of endangering result attained the target (≥ 98%), while the rate of timely notification is needed to improve. Quality inspection shows the CV of APTT in August (5.02%) was rising significantly, beyond the accepted CV (5.0%). We have solved the problem by changing the reagent. The CV of TT in 2014 were all below the allowable CV, thus the allowable CV of the next year lower to 10%. It is an objective

  14. Current Guidelines, Common Clinical Pitfalls, and Future Directions for Laboratory Diagnosis of Lyme Disease, United States

    PubMed Central

    Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul

    2016-01-01

    In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%–40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%–100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics. PMID:27314832

  15. KEY COMPARISON: Final report on CCQM-K69 key comparison: Testosterone glucuronide in human urine

    NASA Astrophysics Data System (ADS)

    Liu, Fong-Ha; Mackay, Lindsey; Murby, John

    2010-01-01

    The CCQM-K69 key comparison of testosterone glucuronide in human urine was organized under the auspices of the CCQM Organic Analysis Working Group (OAWG). The National Measurement Institute Australia (NMIA) acted as the coordinating laboratory for the comparison. The samples distributed for the key comparison were prepared at NMIA with funding from the World Anti-Doping Agency (WADA). WADA granted the approval for this material to be used for the intercomparison provided the distribution and handling of the material were strictly controlled. Three national metrology institutes (NMIs)/designated institutes (DIs) developed reference methods and submitted data for the key comparison along with two other laboratories who participated in the parallel pilot study. A good selection of analytical methods and sample workup procedures was displayed in the results submitted considering the complexities of the matrix involved. The comparability of measurement results was successfully demonstrated by the participating NMIs. Only the key comparison data were used to estimate the key comparison reference value (KCRV), using the arithmetic mean approach. The reported expanded uncertainties for results ranged from 3.7% to 6.7% at the 95% level of confidence and all results agreed within the expanded uncertainty of the KCRV. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  16. Three key residues form a critical contact network in a protein folding transition state

    NASA Astrophysics Data System (ADS)

    Vendruscolo, Michele; Paci, Emanuele; Dobson, Christopher M.; Karplus, Martin

    2001-02-01

    Determining how a protein folds is a central problem in structural biology. The rate of folding of many proteins is determined by the transition state, so that a knowledge of its structure is essential for understanding the protein folding reaction. Here we use mutation measurements-which determine the role of individual residues in stabilizing the transition state-as restraints in a Monte Carlo sampling procedure to determine the ensemble of structures that make up the transition state. We apply this approach to the experimental data for the 98-residue protein acylphosphatase, and obtain a transition-state ensemble with the native-state topology and an average root-mean-square deviation of 6Å from the native structure. Although about 20 residues with small positional fluctuations form the structural core of this transition state, the native-like contact network of only three of these residues is sufficient to determine the overall fold of the protein. This result reveals how a nucleation mechanism involving a small number of key residues can lead to folding of a polypeptide chain to its unique native-state structure.

  17. The History of a Communications Skills Laboratory in the Middle School of New York State School District.

    ERIC Educational Resources Information Center

    Giddings, Louise R.

    An innovative communication skills laboratory, created in 1971 at the middle school of the Greenburgh School District of New York State, focused on non-verbal communication, as well as the language arts and literature. The laboratory was designed to replace an English program that stigmatized low achievers and separated them from their peers. A…

  18. To Improve Homicide Firearm Information Reporting - Rhode Island State Crime Laboratory.

    PubMed

    Jiang, Yongwen; Lyons, Dennis; Northup, Jane B; Hilliard, Dennis; Foss, Karen; Young, Shannon; Viner-Brown, Samara

    2018-05-01

    Information on homicide firearms can be used to help state and local communities understand the problems of violence and decrease injuries and deaths. However, it is difficult to collect these data. To our knowledge, in the public health arena, the National Violent Death Reporting System (NVDRS) is the only system that collects detailed firearm information. The Rhode Island State Crime Laboratory (RISCL) can provide detailed information about the firearms and cartridge cases\\bullets involved in firearm deaths. With help from the RISCL, the firearm information related to homicides in Rhode Island has improved dramatically. In 2015, information on caliber/gauge increased by 80%, the firearm type by 50%, the make by 50%, and the model by 20%. By documenting the process of using information from the RISCL, it is hoped that this process can be used as a model by other states when reporting on violent deaths. [Full article available at http://rimed.org/rimedicaljournal-2018-05.asp].

  19. Principles of visual key construction-with a visual identification key to the Fagaceae of the southeastern United States.

    PubMed

    Kirchoff, Bruce K; Leggett, Roxanne; Her, Va; Moua, Chue; Morrison, Jessica; Poole, Chamika

    2011-01-01

    Advances in digital imaging have made possible the creation of completely visual keys. By a visual key we mean a key based primarily on images, and that contains a minimal amount of text. Characters in visual keys are visually, not verbally defined. In this paper we create the first primarily visual key to a group of taxa, in this case the Fagaceae of the southeastern USA. We also modify our recently published set of best practices for image use in illustrated keys to make them applicable to visual keys. Photographs of the Fagaceae were obtained from internet and herbarium databases or were taken specifically for this project. The images were printed and then sorted into hierarchical groups. These hierarchical groups of images were used to create the 'couplets' in the key. A reciprocal process of key creation and testing was used to produce the final keys. Four keys were created, one for each of the parts-leaves, buds, fruits and bark. Species description pages consisting of multiple images were also created for each of the species in the key. Creation and testing of the key resulted in a modified list of best practices for image use visual keys. The inclusion of images into paper and electronic keys has greatly increased their ease of use. However, virtually all of these keys are still based upon verbally defined, atomistic characters. The creation of primarily visual keys allows us to overcome the well-known limitations of linguistic-based characters and create keys that are much easier to use, especially for botanical novices.

  20. An Efficient and Secure Arbitrary N-Party Quantum Key Agreement Protocol Using Bell States

    NASA Astrophysics Data System (ADS)

    Liu, Wen-Jie; Xu, Yong; Yang, Ching-Nung; Gao, Pei-Pei; Yu, Wen-Bin

    2018-01-01

    Two quantum key agreement protocols using Bell states and Bell measurement were recently proposed by Shukla et al. (Quantum Inf. Process. 13(11), 2391-2405, 2014). However, Zhu et al. pointed out that there are some security flaws and proposed an improved version (Quantum Inf. Process. 14(11), 4245-4254, 2015). In this study, we will show Zhu et al.'s improvement still exists some security problems, and its efficiency is not high enough. For solving these problems, we utilize four Pauli operations { I, Z, X, Y} to encode two bits instead of the original two operations { I, X} to encode one bit, and then propose an efficient and secure arbitrary N-party quantum key agreement protocol. In the protocol, the channel checking with decoy single photons is introduced to avoid the eavesdropper's flip attack, and a post-measurement mechanism is used to prevent against the collusion attack. The security analysis shows the present protocol can guarantee the correctness, security, privacy and fairness of quantum key agreement.

  1. Decoy-state quantum key distribution with more than three types of photon intensity pulses

    NASA Astrophysics Data System (ADS)

    Chau, H. F.

    2018-04-01

    The decoy-state method closes source security loopholes in quantum key distribution (QKD) using a laser source. In this method, accurate estimates of the detection rates of vacuum and single-photon events plus the error rate of single-photon events are needed to give a good enough lower bound of the secret key rate. Nonetheless, the current estimation method for these detection and error rates, which uses three types of photon intensities, is accurate up to about 1 % relative error. Here I report an experimentally feasible way that greatly improves these estimates and hence increases the one-way key rate of the BB84 QKD protocol with unbiased bases selection by at least 20% on average in realistic settings. The major tricks are the use of more than three types of photon intensities plus the fact that estimating bounds of the above detection and error rates is numerically stable, although these bounds are related to the inversion of a high condition number matrix.

  2. Laboratory characterization and astrophysical detection of vibrationally excited states of vinyl cyanide in Orion-KL

    NASA Astrophysics Data System (ADS)

    López, A.; Tercero, B.; Kisiel, Z.; Daly, A. M.; Bermúdez, C.; Calcutt, H.; Marcelino, N.; Viti, S.; Drouin, B. J.; Medvedev, I. R.; Neese, C. F.; Pszczółkowski, L.; Alonso, J. L.; Cernicharo, J.

    2014-12-01

    Context. We perform a laboratory characterization in the 18-1893 GHz range and astronomical detection between 80-280 GHz in Orion-KL with IRAM-30 m of CH2CHCN (vinyl cyanide) in its ground and vibrationally excited states. Aims: Our aim is to improve the understanding of rotational spectra of vibrationally excited vinyl cyanide with new laboratory data and analysis. The laboratory results allow searching for these excited state transitions in the Orion-KL line survey. Furthermore, rotational lines of CH2CHCN contribute to the understanding of the physical and chemical properties of the cloud. Methods: Laboratory measurements of CH2CHCN made on several different frequency-modulated spectrometers were combined into a single broadband 50-1900 GHz spectrum and its assignment was confirmed by Stark modulation spectra recorded in the 18-40 GHz region and by ab-initio anharmonic force field calculations. For analyzing the emission lines of vinyl cyanide detected in Orion-KL we used the excitation and radiative transfer code (MADEX) at LTE conditions. Results: Detailed characterization of laboratory spectra of CH2CHCN in nine different excited vibrational states: ν11 = 1, ν15 = 1, ν11 = 2, ν10 = 1 ⇔ (ν11 = 1,ν15 = 1), ν11 = 3/ν15 = 2/ν14 = 1, (ν11 = 1,ν10 = 1) ⇔ (ν11 = 2,ν15 = 1), ν9 = 1, (ν11 = 1,ν15 = 2) ⇔ (ν10 = 1,ν15 = 1) ⇔ (ν11 = 1,ν14 = 1), and ν11 = 4 are determined, as well as the detection of transitions in the ν11 = 2 and ν11 = 3 states for the first time in Orion-KL and of those in the ν10 = 1 ⇔ (ν11 = 1,ν15 = 1) dyad of states for the first time in space. The rotational transitions of the ground state of this molecule emerge from four cloud components of hot core nature, which trace the physical and chemical conditions of high mass star forming regions in the Orion-KL Nebula. The lowest energy vibrationally excited states of vinyl cyanide, such as ν11 = 1 (at 328.5 K), ν15 = 1 (at 478.6 K), ν11 = 2 (at 657.8 K), the ν10

  3. The "Key" Method of Identifying Igneous and Metamorphic Rocks in Introductory Laboratory.

    ERIC Educational Resources Information Center

    Eves, Robert Leo; Davis, Larry Eugene

    1987-01-01

    Proposes that identification keys provide an orderly strategy for the identification of igneous and metamorphic rocks in an introductory geology course. Explains the format employed in the system and includes the actual key guides for both igneous and metamorphic rocks. (ML)

  4. Current safety practices in nano-research laboratories in China.

    PubMed

    Zhang, Can; Zhang, Jing; Wang, Guoyu

    2014-06-01

    China has become a key player in the global nanotechnology field, however, no surveys have specifically examined safety practices in the Chinese nano-laboratories in depth. This study reports results of a survey of 300 professionals who work in research laboratories that handle nanomaterials in China. We recruited participants at three major nano-research laboratories (which carry out research in diverse fields such as chemistry, material science, and biology) and the nano-chemistry session of the national meeting of the Chinese Chemical Society. Results show that almost all nano-research laboratories surveyed had general safety regulations, whereas less than one third of respondents reported having nanospecific safety rules. General safety measures were in place in most surveyed nano-research laboratories, while nanospecific protective measures existed or were implemented less frequently. Several factors reported from the scientific literature including nanotoxicology knowledge gaps, technical limitations on estimating nano-exposure, and the lack of nano-occupational safety legislation may contribute to the current state of affairs. With these factors in mind and embracing the precautionary principle, we suggest strengthening or providing nanosafety training (including raising risk awareness) and establishing nanosafety guidelines in China, to better protect personnel in the nano-workplace.

  5. Presentation to Ohio State University Dept. of Electrical Engineering ElectroScience Laboratory

    NASA Technical Reports Server (NTRS)

    Fujikawa, Gene

    2002-01-01

    Presentation made during visit to The Ohio State University, ElectroScience Laboratory, on November 14, 2002. An overview of NASA and selected technology products from the Digital Communications Technology Branch (5650) for fiscal year 2003 are highlighted. The purpose of the meeting was to exchange technical information on current aeronautics and space communications research and technology being conducted at NASA Glenn Research Center and to promote faculty/student collaborations of mutual interest.

  6. A Good Name and Great Riches: Rebranding Solid State Physics for the National Laboratories

    NASA Astrophysics Data System (ADS)

    Martin, Joseph

    2012-03-01

    In 1943 Oliver Buckley, lamenting the inadequacy of term ``physics'' to evoke what physicists did, quoted the proverb, ``A good name is rather to be chosen than great riches.'' Some forty years later, solid state physicists confronted similar discontent with their name, precipitating the rise of the appellation ``condensed matter physics.'' Ostensibly a rebranding of a well-established field, the change signaled deeper conceptual and institutional realignment. Whereas ``solid state'' emerged in the 1940s in the service of institutional aims, ``condensed matter'' more accurately captured a distinct set of theoretical and experimental approaches. Reimagining the field around core conceptual approaches set condensed matter apart from the inchoate field of materials science, which subsumed a growing proportion of solid state funding and personnel through the 1980s. Federally funded research installations were the source of ``great riches'' for scientific research. The DOE National Laboratory System and the DARPA network of Interdisciplinary Laboratories, given their responsiveness to shifts in national funding priorities, provide a sensitive historical instrument through which to trace the transition from solid state to condensed matter. The reorganization of solid state in response to the evolution of national priorities and funding practices precipitated a sharpening of the field's intellectual mission. At the same time, it reflected the difficulties solid state faced articulating its intellectual--as opposed to technological--merit. The proverb continues, `` and loving favor rather than silver and gold.'' The adoption of a name that emphasized intellectual cohesion and associated social esteem exposed the growing tension between technology-oriented national funding goals for materials research and condensed matter physics' ascendant intellectual identity.

  7. State of laboratory manual instruction in California community college introductory (non-majors) biology laboratory instruction

    NASA Astrophysics Data System (ADS)

    Priest, Michelle

    College students must complete a life science course prior to graduation for a bachelor's degree. Generally, the course has lecture and laboratory components. It is in the laboratory where there are exceptional opportunities for exploration, challenge and application of the material learned. Optimally, this would utilize the best of inquiry based approaches. Most community colleges are using a home-grown or self written laboratory manual for the direction of work in the laboratory period. Little was known about the motivation, development and adaptation of use. It was also not known about the future of the laboratory manuals in light of the recent learning reform in California Community Colleges, Student Learning Outcomes. Extensive interviews were conducted with laboratory manual authors to determine the motivation, process of development, who was involved and learning framework used in the creation of the manuals. It was further asked of manual authors their ideas about the future of the manual, the development of staff and faculty and finally, the role Student Learning Outcomes would play in the manual. Science faculty currently teaching the non-majors biology laboratories for at least two semesters were surveyed on-line about actual practice of the manual, assessment, manual flexibility, faculty training and incorporation of Student Learning Outcomes. Finally, an evaluation of the laboratory manual was done using an established Laboratory Task Analysis Instrument. Laboratory manuals were evaluated on a variety of categories to determine the level of inquiry instruction done by students in the laboratory section. The results were that the development of homegrown laboratory manuals was done by community colleges in the Los Angeles and Orange Counties in an effort to minimize the cost of the manual to the students, to utilize all the exercises in a particular lab and to effectively utilize the materials already owned by the department. Further, schools wanted to

  8. Undergraduate Skills Laboratories at Sonoma State University

    NASA Astrophysics Data System (ADS)

    Gill, Amandeep; Zack, K.; Mills, H.; Cunningham, B.; Jackowski, S.

    2014-01-01

    Due to the current economic climate, funding sources for many laboratory courses have been cut from university budgets. However, it is still necessary for undergraduates to master laboratory skills to be prepared and competitive applicants when entering the professional world and/or graduate school. In this context, student-led programs may be able to compensate for this lack of formal instruction and reinforce concepts from lecture by applying research techniques to develop hands-on comprehension. The Sonoma State University Chapter of Society of Physics Students has established a peer-led skills lab to teach research techniques in the fields of astronomy and physics. The goal is to alleviate the pressures of both independently learning and efficiently applying techniques to junior and senior-level research projects. These skill labs are especially valuable for nontraditional students who, due to work or family duties, may not get a chance to fully commit to research projects. For example, a topic such as Arduino programming has a multitude of applications in both astronomy and physics, but is not taught in traditional university courses. Although some programming and electronics skills are taught in (separate) classes, they are usually not applied to actual research projects, which combined expertise is needed. For example, in astronomy, there are many situations involving programming telescopes and taking data with electronic cameras. Often students will carry out research using these tools but when something goes wrong, the students will not have the skills to trouble shoot and fix the system. Another astronomical topic to be taught in the skills labs is the analysis of astronomical data, including running remote telescopes, analyzing photometric variability, and understanding the concepts of star magnitudes, flat fields, and biases. These workshops provide a setting in which the student teacher may strengthen his or her understanding of the topic by presenting

  9. Limitations on quantum key repeaters.

    PubMed

    Bäuml, Stefan; Christandl, Matthias; Horodecki, Karol; Winter, Andreas

    2015-04-23

    A major application of quantum communication is the distribution of entangled particles for use in quantum key distribution. Owing to noise in the communication line, quantum key distribution is, in practice, limited to a distance of a few hundred kilometres, and can only be extended to longer distances by use of a quantum repeater, a device that performs entanglement distillation and quantum teleportation. The existence of noisy entangled states that are undistillable but nevertheless useful for quantum key distribution raises the question of the feasibility of a quantum key repeater, which would work beyond the limits of entanglement distillation, hence possibly tolerating higher noise levels than existing protocols. Here we exhibit fundamental limits on such a device in the form of bounds on the rate at which it may extract secure key. As a consequence, we give examples of states suitable for quantum key distribution but unsuitable for the most general quantum key repeater protocol.

  10. Astrochemistry and the Role of Laboratory and Theoretical Support

    NASA Technical Reports Server (NTRS)

    Herbst, E.

    2006-01-01

    We emphasize some current needs of astrochemists for laboratory data. The data are urgently required both to detect molecules in assorted regions and to produce robust models of these regions. Three areas of laboratory-based research are particularly crucial and yet are not being studied in the United States: (i) reactions more complex than the formation of molecular hydrogen occurring on interstellar grain analogs, (ii) molecular spectroscopy in the THz (far-infrared) region of the electromagnetic spectrum, and (iii) gas-phase kinetics of reactions leading to complex molecules. Without solid knowledge of many unstudied but key reactions, both in the gas and on grains, astrochemists will not be in position to keep up with the large amount of new information expected to come from the next generation of telescopes.

  11. Developing a competency framework for U.S. state food and feed testing laboratory personnel.

    PubMed

    Kaml, Craig; Weiss, Christopher C; Dezendorf, Paul; Ishida, Maria; Rice, Daniel H; Klein, Ron; Salfinger, Yvonne

    2014-01-01

    A competency-based training curriculum framework for U.S. state food and feed testing laboratories personnel is being developed by the International Food Protection Training Institute (IFPTI) and three partners. The framework will help laboratories catalog existing training courses/modules, identify training gaps, inform training curricula, and create career-spanning professional development learning paths, ensuring consistent performance expectations and increasing confidence in shared test results. Ultimately, the framework will aid laboratories in meeting the requirements of ISO/IEC 17025 (2005) international accreditation and the U.S. Food Safety Modernization Act (U.S. Public Law 111-353). In collaboration with the Association of Food and Drug Officials, the Association of Public Health Laboratories, and the Association of American Feed Control Officials, IFPTI is carrying out the project in two phases. In 2013, an expert panel of seven subject matter experts developed competency and curriculum frameworks for five professional levels (entry, mid-level, expert, supervisor/manager, and senior administration) across four competency domains (technical, communication, programmatic, and leadership) including approximately 80 competencies. In 2014 the expert panel will elicit feedback from peers and finalize the framework.

  12. Blood Cholesterol Measurement in Clinical Laboratories in the United States. Current Status. A Report from the Laboratory Standardization Panel of the National Cholesterol Education Program.

    ERIC Educational Resources Information Center

    National Heart, Lung, and Blood Inst. (DHHS/NIH), Bethesda, MD.

    Precise and accurate cholesterol measurements are required to identify and treat individuals with high blood cholesterol levels. However, the current state of reliability of blood cholesterol measurements suggests that considerable inaccuracy in cholesterol testing exists. This report describes the Laboratory Standardization Panel findings on the…

  13. A Hierarchical Modulation Coherent Communication Scheme for Simultaneous Four-State Continuous-Variable Quantum Key Distribution and Classical Communication

    NASA Astrophysics Data System (ADS)

    Yang, Can; Ma, Cheng; Hu, Linxi; He, Guangqiang

    2018-06-01

    We present a hierarchical modulation coherent communication protocol, which simultaneously achieves classical optical communication and continuous-variable quantum key distribution. Our hierarchical modulation scheme consists of a quadrature phase-shifting keying modulation for classical communication and a four-state discrete modulation for continuous-variable quantum key distribution. The simulation results based on practical parameters show that it is feasible to transmit both quantum information and classical information on a single carrier. We obtained a secure key rate of 10^{-3} bits/pulse to 10^{-1} bits/pulse within 40 kilometers, and in the meantime the maximum bit error rate for classical information is about 10^{-7}. Because continuous-variable quantum key distribution protocol is compatible with standard telecommunication technology, we think our hierarchical modulation scheme can be used to upgrade the digital communication systems to extend system function in the future.

  14. Security evaluation of the quantum key distribution system with two-mode squeezed states

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Osaki, M.; Ban, M.

    2003-08-01

    The quantum key distribution (QKD) system with two-mode squeezed states has been demonstrated by Pereira et al. [Phys. Rev. A 62, 042311 (2000)]. They evaluate the security of the system based on the signal to noise ratio attained by a homodyne detector. In this paper, we discuss its security based on the error probability individually attacked by eavesdropper with the unambiguous or the error optimum detection. The influence of the energy loss at transmission channels is also taken into account. It will be shown that the QKD system is secure under these conditions.

  15. Key cost drivers of pharmaceutical clinical trials in the United States.

    PubMed

    Sertkaya, Aylin; Wong, Hui-Hsing; Jessup, Amber; Beleche, Trinidad

    2016-04-01

    The increasing cost of clinical research has significant implications for public health, as it affects drug companies' willingness to undertake clinical trials, which in turn limits patient access to novel treatments. Thus, gaining a better understanding of the key cost drivers of clinical research in the United States is important. The study which is based on a report prepared by Eastern Research Group, Inc., for the US Department of Health and Human Services, examined different factors, such as therapeutic area, patient recruitment, administrative staff, and clinical procedure expenditures, and their contribution to pharmaceutical clinical trial costs in the United States by clinical trial phase. The study used aggregate data from three proprietary databases on clinical trial costs provided by Medidata Solutions. We evaluated per-study costs across therapeutic areas by aggregating detailed (per patient and per site) cost information. We also compared average expenditures on cost drivers with the use of weighted mean and standard deviation statistics. Therapeutic area was an important determinant of clinical trial costs by phase. The average cost of a Phase 1 study conducted at a US site ranged from US$1.4 million (pain and anesthesia) to US$6.6 million (immunomodulation), including estimated site overhead and monitoring costs of the sponsoring organization. A Phase 2 study cost from US$7.0 million (cardiovascular) to US$19.6 million (hematology), whereas a Phase 3 study cost ranged from US$11.5 million (dermatology) to US$52.9 (pain and anesthesia) on average. Across all study phases and excluding estimated site overhead costs and costs for sponsors to monitor the study, the top three cost drivers of clinical trial expenditures were clinical procedure costs (15%-22% of total), administrative staff costs (11%-29% of total), and site monitoring costs (9%-14% of total). The data were from 2004 through 2012 and were not adjusted for inflation. Additionally

  16. Teaching Laboratory Renovation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Zuhairi, Ali Jassim; Al-Dahhan, Wedad; Hussein, Falah

    Scientists at universities across Iraq are actively working to report actual incidents and accidents occurring in their laboratories, as well as structural improvements made to improve safety and security, to raise awareness and encourage openness, leading to widespread adoption of robust Chemical Safety and Security (CSS) practices. The improvement of students’ understanding of concepts in science and its applications, practical scientific skills and understanding of how science and scientists work in laboratory experiences have been considered key aspects of education in science for over 100 years. Facility requirements for the necessary level of safety and security combined with specific requirementsmore » relevant to the course to be conducted dictate the structural design of a particular laboratory, and the design process must address both. This manuscript is the second in a series of five case studies describing laboratory incidents, accidents, and laboratory improvements. We summarize the process used to guide a major renovation of the chemistry instructional laboratory facilities at Al-Nahrain University and discuss lessons learned from the project.« less

  17. Final report on APMP.T-K7 key comparison of water triple point cells

    NASA Astrophysics Data System (ADS)

    Tsai, S. F.; White, R.; Tamba, J.; Yamazawa, K.; Ho, M. K.; Tsui, C. M.; Zaid, G.; Achmadi, A.; Gam, K. S.; Othman, H.; Ali, N. M.; Yuan, K. H.; Shaochun, Y.; Liedberg, H.; Yaokulbodee, C.

    2016-01-01

    APMP.T-K7, was held from February 2008 to September 2009 to compare the national realizations of the water triple point among eleven NMIs. To reach the objective, each participating laboratory sent a transfer cell to CMS and stated a value for the temperature difference of the transfer cell, relative to the corresponding national standard, representing 273.16 K. CMS (Taiwan) organized the comparison, with the support from co-pilot institutes MSL (New Zealand) and NMIJ (Japan). The other eight participating laboratories included NMIA, SCL, KIM-LIPI, KRISS, NMIM/SIRIM, NMC, NMISA, and NIMT. This report presents the results of the TPW comparison, gives detailed information about the measurements made at the CMS and at the participating laboratories, and aims to link the results of APMP.T-K7 to CCT-K7. The results of this key comparison are also represented in the form of degrees of equivalence for the purposes of the MRA. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Laboratories new to the ICRM.

    PubMed

    Karam, Lisa; Anagnostakis, Marios J; Gudelis, Arunas; Marsoem, Pujadi; Mauring, Alexander; Wurdiyanto, Gatot; Yücel, Ülkü

    2012-09-01

    The Scientific Committee of the ICRM decided, for the 2011 Conference, to present laboratories that are at a key developmental stage in establishing, expanding or applying radionuclide metrology capabilities. The expansion of radionuclide metrology capabilities is crucial to meet evolving and emerging needs in health care, environmental monitoring, and nuclear energy. Five laboratories (from Greece, Lithuania, Indonesia, Norway and Turkey) agreed to participate. Each laboratory is briefly introduced, and examples of their capabilities and standardization activities are discussed. Published by Elsevier Ltd.

  19. Teaching pediatric laboratory medicine to pathology residents.

    PubMed

    Pysher, Theodore J; Bach, Philip R; Geaghan, Sharon M; Hamilton, Marilyn S; Laposata, Michael; Lockitch, Gillian; Brugnara, Carlo; Coffin, Cheryl M; Pasquali, Marzia; Rinaldo, Piero; Roberts, William L; Rutledge, Joe C; Ashwood, Edward R; Blaylock, Robert C; Campos, Joseph M; Goldsmith, Barbara; Jones, Patricia M; Lim, Megan; Meikle, A Wayne; Perkins, Sherrie L; Perry, Deborah A; Petti, Cathy A; Rogers, Beverly B; Steele, Paul E; Weiss, Ronald L; Woods, Gail

    2006-07-01

    Laboratory data are essential to the medical care of fetuses, infants, children, and adolescents. However, the performance and interpretation of laboratory tests on specimens from these patients, which may constitute a significant component of the workload in general hospitals and integrated health care systems as well as specialized perinatal or pediatric centers, present unique challenges to the clinical pathologist and the laboratory. Therefore, pathology residents should receive training in pediatric laboratory medicine. Children's Health Improvement through Laboratory Diagnostics, a group of pathologists and laboratory scientists with interest and expertise in pediatric laboratory medicine, convened a task force to develop a list of curriculum topics, key resources, and training experiences in pediatric laboratory medicine for trainees in anatomic and clinical pathology or straight clinical pathology residency programs and in pediatric pathology fellowship programs. Based on the experiences of 11 training programs, we have compiled a comprehensive list of pediatric topics in the areas of clinical chemistry, endocrinology, hematology, urinalysis, coagulation medicine, transfusion medicine, immunology, microbiology and virology, biochemical genetics, cytogenetics and molecular diagnostics, point of care testing, and laboratory management. This report also includes recommendations for training experiences and a list of key texts and other resources in pediatric laboratory medicine. Clinical pathologists should be trained to meet the laboratory medicine needs of pediatric patients and to assist the clinicians caring for these patients with the selection and interpretation of laboratory studies. This review helps program directors tailor their curricula to more effectively provide this training.

  20. Phillips Laboratory Geophysics Scholar Program

    DTIC Science & Technology

    1993-09-30

    research at Phillips Laboratory . Research sponsored by Air Force Geophysics Laboratory ...Geophysics Laboratory (now the Phillips Laboratory , Geophysics Directorate), United States Air Force for its sponsorship of this research through the Air ...September 1993 Approved for public release; distribution unlimited PHILLIPS LABORATORY Directorate of Geophysics AIR FORCE MATERIEL COMMAND

  1. State Differences: The Key to Demographics.

    ERIC Educational Resources Information Center

    Hodgkinson, Harold

    1999-01-01

    This companion piece to a 1997 article examines United States demographic trends, such as diversity by age, "race" and U.S. Census racial classifications, wealth, transiency, suburbanization and sprawl, and immigration, focusing on differences among states and metro regions. Nothing, including achievement scores, social services, and…

  2. Quantum key distribution with finite resources: Secret key rates via Renyi entropies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abruzzo, Silvestre; Kampermann, Hermann; Mertz, Markus

    A realistic quantum key distribution (QKD) protocol necessarily deals with finite resources, such as the number of signals exchanged by the two parties. We derive a bound on the secret key rate which is expressed as an optimization problem over Renyi entropies. Under the assumption of collective attacks by an eavesdropper, a computable estimate of our bound for the six-state protocol is provided. This bound leads to improved key rates in comparison to previous results.

  3. Oxygen key to the new superconductors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This paper has briefings from the 1987 Spring Meeting of the Materials Research Society that was held in Anaheim, California, from 21 to 24 April. Except for an impassioned presentation by Juei-Teng Chen of Wayne State University, who sought to convince listeners that a group there had seen clear signs of superconductivity at 240 K, which is ambient temperature during a cold night on the northern plains, no significant indications of room-temperature superconductivity were reported. The most skeptical view was that of Theodore Geballe of Stanford University, who suggested that some of the unreproducible signs seen in several laboratories couldmore » be due to something other than superconductivity, as similar effects disappeared in Stanford samples with repeated cycling between room and liquid-nitrogen temperature. If there was one theme at the symposium, it was that oxygen is the key to the family of rare-earth-based ceramic materials now in hand that remain superconducting up to about 100 K.« less

  4. Key results of battery performance and life tests at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1991-12-01

    Advanced battery technology evaluations are performed under simulated electric vehicle operating conditions at Argonne National Laboratory's & Diagnostic Laboratory (ADL). The ADL provide a common basis for both performance characterization and life evaluation with unbiased application of tests and analyses. This paper summarizes the performance characterizations and life evaluations conducted in 1991 on twelve single cells and eight 3- to 360-cell modules that encompass six battery technologies (Na/S, Li/MS, Ni/MH, Zn/Br, Ni/Fe, and Pb-Acid). These evaluations were performed for the Department of Energy, Office of Transportation Technologies, Electric and Hybrid Propulsion Division. The results measure progress in battery R & D programs, compare battery technologies, and provide basic data for modeling and continuing R & D to battery users, developers, and program managers.

  5. Final report of the APMP water flow key comparison: APMP.M.FF-K1

    NASA Astrophysics Data System (ADS)

    Lee, Kwang-Bock; Chun, Sejong; Terao, Yoshiya; Thai, Nguyen Hong; Tsair Yang, Cheng; Tao, Meng; Gutkin, Mikhail B.

    2011-01-01

    The key comparison, APMP.M.FF-K1, was undertaken by APMP/TCFF, the Technical Committee for Fluid Flow (TCFF) under the Asia Pacific Metrology Program (APMP). One objective of the key comparison was to demonstrate the degree of equivalence among six participating laboratories (KRISS, NMIJ, VMI, CMS, NIM and VNIIM) in water flow rate metrology by comparing the results with the key comparison reference value (KCRV) determined from the CCM.FF-K1 key comparison. The other objective of this key comparison was to provide supporting evidence for the calibration and measurement capabilities (CMCs), which had been declared by the participating laboratories during this key comparison. The Transfer Standard Package (TSP) was a Coriolis mass flowmeter, which had been used in the CCM.FF-K1 key comparison. Because the K-factors in the APMP.M.FF-K1 key comparison were slightly lower than the K-factors of the CCM.FF-K1 key comparison due to long-term drifts of the TSP, a correction value D was introduced. The value of D was given by a weighted sum between two link laboratories (NMIJ and KRISS), which participated in both the CCM.FF-K1 and the APMP.M.FF-K1 key comparisons. By this correction, the K-factors were laid between 12.004 and 12.017 at either low (Re = 254 000) or high (Re = 561 000) flow rates. Most of the calibration data were within expected uncertainty bounds. However, some data showed undulations, which gave large fluctuations of the metering factor at Re = 561 000. Calculation of degrees of equivalence showed that all the participating laboratories had deviations between -0.009 and 0.007 pulses/kg from the CCM.FF-K1 KCRV at either the low or the high flow rates. In case of En calculation, all the participating laboratories showed values less than 1, indicating that the corrected K-factors of all the laboratories were equivalent with the KCRV at both Re = 254 000 and 561 000. When the corrected K-factors from two participating laboratories were compared, all the

  6. Flexible Asymmetrical Solid-State Supercapacitors Based on Laboratory Filter Paper.

    PubMed

    Zhang, Leicong; Zhu, Pengli; Zhou, Fengrui; Zeng, Wenjin; Su, Haibo; Li, Gang; Gao, Jihua; Sun, Rong; Wong, Ching-Ping

    2016-01-26

    In this study, a flexible asymmetrical all-solid-state supercapacitor with high electrochemical performance was fabricated with Ni/MnO2-filter paper (FP) as the positive electrode and Ni/active carbon (AC)-filter paper as negative electrode, separated with poly(vinyl alcohol) (PVA)-Na2SO4 electrolyte. A simple procedure, such as electroless plating, was introduced to prepare the Ni/MnO2-FP electrode on the conventional laboratory FP, combined with the subsequent step of electrodeposition. Electrochemical results show that the as-prepared electrodes display outstanding areal specific capacitance (1900 mF/cm(2) at 5 mV/s) and excellent cycling performance (85.1% retention after 1000 cycles at 20 mA/cm(2)). Such a flexible supercapacitor assembled asymmetrically in the solid state exhibits a large volume energy density (0.78 mWh/cm(3)) and superior flexibility under different bending conditions. It has been demonstrated that the supercapacitors could be used as a power source to drive a 3 V light-emitting diode indicator. This study may provide an available method for designing and fabricating flexible supercapacitors with high performance in the application of wearable and portable electronics based on easily available materials.

  7. Laboratory research of fracture geometry in multistage HFF in triaxial state

    NASA Astrophysics Data System (ADS)

    Bondarenko, T. M.; Hou, B.; Chen, M.; Yan, L.

    2017-05-01

    Multistage hydraulic fracturing of formation (HFF) in wells with horizontal completion is an efficientmethod for intensifying oil extraction which, as a rule, is used to develop nontraditional collectors. It is assumed that the complicated character of HFF fractures significantly influences the fracture geometry in the rock matrix. Numerous theoretical models proposed to predict the fracture geometry and the character of interaction of mechanical stresses in the multistage HFF have not been proved experimentally. In this paper, we present the results of laboratory modeling of the multistage HFF performed on a contemporary laboratory-scale plant in the triaxial stress state by using a gel-solution as the HFF agent. As a result of the experiment, a fracturing pattern was formed in the cubic specimen of the model material. The laboratory results showed that a nearly plane fracture is formed at the firstHFF stage, while a concave fracture is formed at the second HFF stage. The interaction of the stress fields created by the two principal HFF fractures results in the growth of secondary fractures whose directions turned out to be parallel to the modeled well bore. But this stress interference leads to a decrease in the width of the second principal fracture. It is was discovered that the penny-shaped fracture model is more appropriate for predicting the geometry of HFF fractures in horizontal wells than the two-dimensional models of fracture propagation (PKN model, KGD model). A computational experiment based on the boundary element method was carried out to obtain the qualitative description of the multistage HFF processes. As a result, a mechanical model of fracture propagation was constructed,which was used to obtain the mechanical stress field (the stress contrast) and the fracture opening angle distribution over fracture length and fracture orientation direction. The conclusions made in the laboratory modeling of the multistage HFF technology agree well with the

  8. Final report on EUROMET key comparison EUROMET.M.D-K2 (EUROMET 627) "Comparison of density determinations of liquid samples"

    NASA Astrophysics Data System (ADS)

    Bettin, Horst; Heinonen, Martti; Gosset, André; Zelenka, Zoltán; Lorefice, Salvatore; Hellerud, Kristen; Durlik, Hanna; Jordaan, Werner; Field, Ireen

    2016-01-01

    The results of the key comparison EUROMET 627 (EUROMET.M.D-K2) are presented. This project covered the density measurements of three liquids: dodecane, water and an oil of high viscosity measured at 15 °C, 20 °C and 40 °C. Seven European metrology laboratories and the South African laboratory CSIR-NML (now: NMISA) measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards between 04 October 2001 and 18 December 2001. The stability and homogeneity of the liquids were investigated by the pilot laboratory PTB. The results generally show good agreement among the participants. Only for the simple Mohr-Westphal balances do the uncertainties seem to be underestimated by the laboratories. Furthermore, the measurement of high-viscosity oil was difficult for some laboratories. Nevertheless, the five laboratories PTB/DE, BNM/FR (now: LNE/FR), OMH/HU (now: MKEH/HU), IMGC/IT (now: INRIM/IT) and GUM/PL agree with each other for stated uncertainties of 0.05 kg/m3 or less. This satisfies the current needs of customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. No reference values were calculated since the subsequent CCM key comparison CCM.D-K2 had a different scope and the EUROMET 627 comparison was soon superseded by the EURAMET 1019 (EURAMET.M.D-K2) comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  9. Optimal attacks on qubit-based Quantum Key Recycling

    NASA Astrophysics Data System (ADS)

    Leermakers, Daan; Škorić, Boris

    2018-03-01

    Quantum Key Recycling (QKR) is a quantum cryptographic primitive that allows one to reuse keys in an unconditionally secure way. By removing the need to repeatedly generate new keys, it improves communication efficiency. Škorić and de Vries recently proposed a QKR scheme based on 8-state encoding (four bases). It does not require quantum computers for encryption/decryption but only single-qubit operations. We provide a missing ingredient in the security analysis of this scheme in the case of noisy channels: accurate upper bounds on the required amount of privacy amplification. We determine optimal attacks against the message and against the key, for 8-state encoding as well as 4-state and 6-state conjugate coding. We provide results in terms of min-entropy loss as well as accessible (Shannon) information. We show that the Shannon entropy analysis for 8-state encoding reduces to the analysis of quantum key distribution, whereas 4-state and 6-state suffer from additional leaks that make them less effective. From the optimal attacks we compute the required amount of privacy amplification and hence the achievable communication rate (useful information per qubit) of qubit-based QKR. Overall, 8-state encoding yields the highest communication rates.

  10. Protein crystal growth results from the United States Microgravity Laboratory-1 mission

    NASA Technical Reports Server (NTRS)

    Delucas, Lawrence J.; Moore, K. M.; Vanderwoerd, M.; Bray, T. L.; Smith, C.; Carson, M.; Narayana, S. V. L.; Rosenblum, W. M.; Carter, D.; Clark, A. D, Jr.

    1994-01-01

    Protein crystal growth experiments have been performed by this laboratory on 18 Space Shuttle missions since April, 1985. In addition, a number of microgravity experiments also have been performed and reported by other investigators. These Space Shuttle missions have been used to grow crystals of a variety of proteins using vapor diffusion, liquid diffusion, and temperature-induced crystallization techniques. The United States Microgravity Laboratory - 1 mission (USML-1, June 25 - July 9, 1992) was a Spacelab mission dedicated to experiments involved in materials processing. New protein crystal growth hardware was developed to allow in orbit examination of initial crystal growth results, the knowledge from which was used on subsequent days to prepare new crystal growth experiments. In addition, new seeding hardware and techniques were tested as well as techniques that would prepare crystals for analysis by x-ray diffraction, a capability projected for the planned Space Station. Hardware that was specifically developed for the USML-1 mission will be discussed along with the experimental results from this mission.

  11. Assessing Key Competences across the Curriculum--And Europe

    ERIC Educational Resources Information Center

    Pepper, David

    2011-01-01

    The development of key competences for lifelong learning has been an important policy imperative for EU Member States. The European Reference Framework of key competences (2006) built on previous developments by the OECD, UNESCO and Member States themselves. It defined key competences as knowledge, skills and attitudes applied appropriately to…

  12. Managing demand for laboratory tests: a laboratory toolkit.

    PubMed

    Fryer, Anthony A; Smellie, W Stuart A

    2013-01-01

    Healthcare budgets worldwide are facing increasing pressure to reduce costs and improve efficiency, while maintaining quality. Laboratory testing has not escaped this pressure, particularly since pathology investigations cost the National Health Service £2.5 billion per year. Indeed, the Carter Review, a UK Department of Health-commissioned review of pathology services in England, estimated that 20% of this could be saved by improving pathology services, despite an average annual increase of 8%-10% in workload. One area of increasing importance is managing the demands for pathology tests and reducing inappropriate requesting. The Carter Review estimated that 25% of pathology tests were unnecessary, representing a huge potential waste. Certainly, the large variability in levels of requesting between general practitioners suggests that inappropriate requesting is widespread. Unlocking the key to this variation and implementing measures to reduce inappropriate requesting would have major implications for patients and healthcare resources alike. This article reviews the approaches to demand management. Specifically, it aims to (a) define demand management and inappropriate requesting, (b) assess the drivers for demand management, (c) examine the various approaches used, illustrating the potential of electronic requesting and (d) provide a wider context. It will cover issues, such as educational approaches, information technology opportunities and challenges, vetting, duplicate request identification and management, the role of key performance indicators, profile composition and assessment of downstream impact of inappropriate requesting. Currently, many laboratories are exploring demand management using a plethora of disparate approaches. Hence, this review seeks to provide a 'toolkit' with the view to allowing laboratories to develop a standardised demand management strategy.

  13. Laboratory Response to Ebola - West Africa and United States.

    PubMed

    Sealy, Tara K; Erickson, Bobbie R; Taboy, Céline H; Ströher, Ute; Towner, Jonathan S; Andrews, Sharon E; Rose, Laura E; Weirich, Elizabeth; Lowe, Luis; Klena, John D; Spiropoulou, Christina F; Rayfield, Mark A; Bird, Brian H

    2016-07-08

    The 2014-2016 Ebola virus disease (Ebola) epidemic in West Africa highlighted the need to maintain organized laboratory systems or networks that can be effectively reorganized to implement new diagnostic strategies and laboratory services in response to large-scale events. Although previous Ebola outbreaks enabled establishment of critical laboratory practice safeguards and diagnostic procedures, this Ebola outbreak in West Africa highlighted the need for planning and preparedness activities that are better adapted to emerging pathogens or to pathogens that have attracted little commercial interest. The crisis underscored the need for better mechanisms to streamline development and evaluation of new diagnostic assays, transfer of material and specimens between countries and organizations, and improved processes for rapidly deploying health workers with specific laboratory expertise. The challenges and events of the outbreak forced laboratorians to examine not only the comprehensive capacities of existing national laboratory systems to recognize and respond to events, but also their sustainability over time and the mechanisms that need to be pre-established to ensure effective response. Critical to this assessment was the recognition of how response activities (i.e., infrastructure support, logistics, and workforce supplementation) can be used or repurposed to support the strengthening of national laboratory systems during the postevent transition to capacity building and recovery. This report compares CDC's domestic and international laboratory response engagements and lessons learned that can improve future responses in support of the International Health Regulations and Global Health Security Agenda initiatives.The activities summarized in this report would not have been possible without collaboration with many U.S. and international partners (http://www.cdc.gov/vhf/ebola/outbreaks/2014-west-africa/partners.html).

  14. Quality Indicators in Laboratory Medicine: from theory to practice. Preliminary data from the IFCC Working Group Project "Laboratory Errors and Patient Safety".

    PubMed

    Sciacovelli, Laura; O'Kane, Maurice; Skaik, Younis Abdelwahab; Caciagli, Patrizio; Pellegrini, Cristina; Da Rin, Giorgio; Ivanov, Agnes; Ghys, Timothy; Plebani, Mario

    2011-05-01

    The adoption of Quality Indicators (QIs) has prompted the development of tools to measure and evaluate the quality and effectiveness of laboratory testing, first in the hospital setting and subsequently in ambulatory and other care settings. While Laboratory Medicine has an important role in the delivery of high-quality care, no consensus exists as yet on the use of QIs focussing on all steps of the laboratory total testing process (TTP), and further research in this area is required. In order to reduce errors in laboratory testing, the IFCC Working Group on "Laboratory Errors and Patient Safety" (WG-LEPS) developed a series of Quality Indicators, specifically designed for clinical laboratories. In the first phase of the project, specific QIs for key processes of the TTP were identified, including all the pre-, intra- and post-analytic steps. The overall aim of the project is to create a common reporting system for clinical laboratories based on standardized data collection, and to define state-of-the-art and Quality Specifications (QSs) for each QI independent of: a) the size of organization and type of activities; b) the complexity of processes undertaken; and c) different degree of knowledge and ability of the staff. The aim of the present paper is to report the results collected from participating laboratories from February 2008 to December 2009 and to identify preliminary QSs. The results demonstrate that a Model of Quality Indicators managed as an External Quality Assurance Program can serve as a tool to monitor and control the pre-, intra- and post-analytical activities. It might also allow clinical laboratories to identify risks that lead to errors resulting in patient harm: identification and design of practices that eliminate medical errors; the sharing of information and education of clinical and laboratory teams on practices that reduce or prevent errors; the monitoring and evaluation of improvement activities.

  15. The State of Organic Teaching Laboratories

    ERIC Educational Resources Information Center

    Horowitz, Gail

    2007-01-01

    The changes that have taken place in the organic chemistry laboratory course since 1980s are reviewed with reference to the quantity and diversity of discovery-based experiments available to date. The data illustrates that significant progress is towards accomplishing dramatic changes such as the almost universal adoption of microscale, the use of…

  16. BSL-3 laboratory practices in the United States: comparison of select agent and non-select agent facilities.

    PubMed

    Richards, Stephanie L; Pompei, Victoria C; Anderson, Alice

    2014-01-01

    New construction of biosafety level 3 (BSL-3) laboratories in the United States has increased in the past decade to facilitate research on potential bioterrorism agents. The Centers for Disease Control and Prevention inspect BSL-3 facilities and review commissioning documentation, but no single agency has oversight over all BSL-3 facilities. This article explores the extent to which standard operating procedures in US BSL-3 facilities vary between laboratories with select agent or non-select agent status. Comparisons are made for the following variables: personnel training, decontamination, personal protective equipment (PPE), medical surveillance, security access, laboratory structure and maintenance, funding, and pest management. Facilities working with select agents had more complex training programs and decontamination procedures than non-select agent facilities. Personnel working in select agent laboratories were likely to use powered air purifying respirators, while non-select agent laboratories primarily used N95 respirators. More rigorous medical surveillance was carried out in select agent workers (although not required by the select agent program) and a higher level of restrictive access to laboratories was found. Most select agent and non-select agent laboratories reported adequate structural integrity in facilities; however, differences were observed in personnel perception of funding for repairs. Pest management was carried out by select agent personnel more frequently than non-select agent personnel. Our findings support the need to promote high quality biosafety training and standard operating procedures in both select agent and non-select agent laboratories to improve occupational health and safety.

  17. Laboratory Surge Response to Pandemic (H1N1) 2009 Outbreak, New York City Metropolitan Area, USA

    PubMed Central

    Crawford, James M.; Stallone, Robert; Zhang, Fan; Gerolimatos, Mary; Korologos, Diamanto D.; Sweetapple, Carolyn; de Geronimo, Marcella; Dlugacz, Yosef; Armellino, Donna M.

    2010-01-01

    The North Shore–Long Island Jewish Health System Laboratories serve 15 hospitals and affiliated regional physician practices in the New York City metropolitan area, with virus testing performed at a central reference laboratory. The influenza A pandemic (H1N1) 2009 outbreak began in this area on April 24, 2009, and within weeks respiratory virus testing increased 7.5 times. In response, laboratory and client service workforces were increased, physical plant build-out was completed, testing paradigms were converted from routine screening tests and viral culture to a high-capacity molecular assay for respiratory viruses, laboratory information system interfaces were built, and same-day epidemiologic reports were produced. Daily review by leadership of data from emergency rooms, hospital facilities, and the Health System Laboratories enabled real-time management of unfolding events. The ability of System laboratories to rapidly increase to high-volume comprehensive diagnostics, including influenza A subtyping, provided key epidemiologic information for local and state public health departments. PMID:20031036

  18. Laboratory surge response to pandemic (H1N1) 2009 outbreak, New York City metropolitan area, USA.

    PubMed

    Crawford, James M; Stallone, Robert; Zhang, Fan; Gerolimatos, Mary; Korologos, Diamanto D; Sweetapple, Carolyn; de Geronimo, Marcella; Dlugacz, Yosef; Armellino, Donna M; Ginocchio, Christine C

    2010-01-01

    The North Shore-Long Island Jewish Health System Laboratories serve 15 hospitals and affiliated regional physician practices in the New York City metropolitan area, with virus testing performed at a central reference laboratory. The influenza A pandemic (H1N1) 2009 outbreak began in this area on April 24, 2009, and within weeks respiratory virus testing increased 7.5 times. In response, laboratory and client service workforces were increased, physical plant build-out was completed, testing paradigms were converted from routine screening tests and viral culture to a high-capacity molecular assay for respiratory viruses, laboratory information system interfaces were built, and same-day epidemiologic reports were produced. Daily review by leadership of data from emergency rooms, hospital facilities, and the Health System Laboratories enabled real-time management of unfolding events. The ability of System laboratories to rapidly increase to high-volume comprehensive diagnostics, including influenza A subtyping, provided key epidemiologic information for local and state public health departments.

  19. Inverter testing at Sandia National Laboratories

    NASA Astrophysics Data System (ADS)

    Ginn, Jerry W.; Bonn, Russell H.; Sittler, Greg

    1997-02-01

    Inverters are key building blocks of photovoltaic (PV) systems that produce ac power. The balance of systems (BOS) portion of a PV system can account for up to 50% of the system cost, and its reliable operation is essential for a successful PV system. As part of its BOS program, Sandia National Laboratories (SNL) maintains a laboratory wherein accurate electrical measurements of power systems can be made under a variety of conditions. This paper outlines the work that is done in that laboratory.

  20. What are the keys to successful adrenal venous sampling (AVS) in patients with primary aldosteronism?

    PubMed

    Young, William F; Stanson, Anthony W

    2009-01-01

    Adrenal venous sampling (AVS) is the criterion standard to distinguish between unilateral and bilateral adrenal disease in patients with primary aldosteronism. The keys to successful AVS include appropriate patient selection, careful patient preparation, focused technical expertise, defined protocol, and accurate data interpretation. The use of AVS should be based on patient preferences, patient age, clinical comorbidities, and the clinical probability of finding an aldosterone-producing adenoma. AVS is optimally performed in the fasting state in the morning. AVS is an intricate procedure because the right adrenal vein is small and may be difficult to locate - the success rate depends on the proficiency of the angiographer. The key factors that determine the successful catheterization of both adrenal veins are experience, dedication and repetition. With experience, and focusing the expertise to 1 or 2 radiologists at a referral centre, the AVS success rate can be as high as 96%. A centre-specific, written protocol is mandatory. The protocol should be developed by an interested group of endocrinologists, radiologists and laboratory personnel. Safeguards should be in place to prevent mislabelling of the blood tubes in the radiology suite and to prevent sample mix-up in the laboratory.

  1. Observations of the Performance of the U.S. Laboratory Architecture

    NASA Technical Reports Server (NTRS)

    Jones, Rod

    2002-01-01

    The United States Laboratory Module "Destiny" was the product of many architectural, technology, manufacturing, schedule and cost constraints which spanned 15 years. Requirements for the Space Station pressurized elements were developed and baselined in the mid to late '80's. Although the station program went through several design changes the fundamental requirements that drove the architecture did not change. Manufacturing of the U.S. Laboratory began in the early 90's. Final assembly and checkout testing completed in December of 2000. Destiny was launched, mated to the International Space Station and successfully activated on the STS-98 mission in February of 2001. The purpose of this paper is to identify key requirements, which directly or indirectly established the architecture of the U.S. Laboratory. Provide an overview of how that architecture affected the manufacture, assembly, test, and activation of the module on-orbit. And finally, through observations made during the last year of operation, provide considerations in the development of future requirements and mission integration controls for space habitats.

  2. 7 CFR 996.21 - USDA laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.21 USDA laboratory. USDA laboratory means laboratories of the Science and Technology Programs, Agricultural Marketing...

  3. Redox states of Desulfovibrio vulgaris DsrC, a key protein in dissimilatory sulfite reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venceslau, Sofia S.; Cort, John R.; Baker, Erin S.

    2013-11-29

    Highlights: •DsrC is known to interact with the dissimilatory sulfite reductase enzyme (DsrAB). •We show that, however, most cellular DsrC is not associated with DsrAB. •A gel-shift assay was developed that allows monitoring of the DsrC redox state. •The DsrC intramolecularly oxidized state could only be produced by arginine treatment. -- Abstract: Dissimilatory reduction of sulfite is carried out by the siroheme enzyme DsrAB, with the involvement of the protein DsrC, which has two conserved redox-active cysteines. DsrC was initially believed to be a third subunit of DsrAB. Here, we report a study of the distribution of DsrC in cellmore » extracts to show that, in the model sulfate reducer Desulfovibrio vulgaris, the majority of DsrC is not associated with DsrAB and is thus free to interact with other proteins. In addition, we developed a cysteine-labelling gel-shift assay to monitor the DsrC redox state and behaviour, and procedures to produce the different redox forms. The oxidized state of DsrC with an intramolecular disulfide bond, which is proposed to be a key metabolic intermediate, could be successfully produced for the first time by treatment with arginine.« less

  4. Regulatory issues in accreditation of toxicology laboratories.

    PubMed

    Bissell, Michael G

    2012-09-01

    Clinical toxicology laboratories and forensic toxicology laboratories operate in a highly regulated environment. This article outlines major US legal/regulatory issues and requirements relevant to accreditation of toxicology laboratories (state and local regulations are not covered in any depth). The most fundamental regulatory distinction involves the purposes for which the laboratory operates: clinical versus nonclinical. The applicable regulations and the requirements and options for operations depend most basically on this consideration, with clinical toxicology laboratories being directly subject to federal law including mandated options for accreditation and forensic toxicology laboratories being subject to degrees of voluntary or state government–required accreditation.

  5. Teaching laboratory neuroscience at bowdoin: the laboratory instructor perspective.

    PubMed

    Hauptman, Stephen; Curtis, Nancy

    2009-01-01

    Bowdoin College is a small liberal arts college that offers a comprehensive Neuroscience major. The laboratory experience is an integral part of the major, and many students progress through three stages. A core course offers a survey of concepts and techniques. Four upper-level courses function to give students more intensive laboratory research experience in neurophysiology, molecular neurobiology, social behavior, and learning and memory. Finally, many majors choose to work in the individual research labs of the Neuroscience faculty. We, as laboratory instructors, are vital to the process, and are actively involved in all aspects of the lab-based courses. We provide student instruction in state of the art techniques in neuroscience research. By sharing laboratory teaching responsibilities with course professors, we help to prepare students for careers in laboratory neuroscience and also support and facilitate faculty research programs.

  6. Salaries and compensation practices in public health, environmental, and agricultural laboratories: findings from a 2010 national survey.

    PubMed

    DeBoy, John M; Boulton, Matthew L; Carpenter, David F

    2013-01-01

    The public health, environmental, and agricultural laboratory (PHEAL) workforce is a key component of the public health infrastructure. The national laboratory workforce faces an ongoing challenge of recruitment and retention of workers often related to pay and other compensation issues. To collect information on laboratory salaries and laboratory compensation practices using a national compensation survey targeting the PHEAL workforce. Seventy-three of 109 (67%) PHEAL directors in the 50 states and District of Columbia collectively employ 3723/4830 (77%) PHEAL employees in the United States. A standardized survey was developed and administered in 2010. Compensation data were compiled by job classification, geographic region, laboratory gross operating budget size, laboratory staff size, and laboratory type. Laboratory staff size ranged from 3 to 327 individuals (mean = 74 and median = 51). Median base salaries were lowest in the Southwest and South and highest in the Mountain and Pacific regions. Mean and median laboratory gross operating budgets for all participating PHEALs were $8 609 238 and $5 671 500, respectively. Extra cash compensation, used by 8 of 60 (13.3%) PHEALs, was more likely to go to a scientist-manager or scientist-supervisor. In 2010, a standardized national compensation survey of technical and scientific public health employees working in 73 PHEALs was effective in collecting previously unavailable data about laboratory salaries, laboratory budgets, and payroll practices. Laboratory salaries varied by geographic region and there was an uneven distribution of extra cash compensation among job classifications. The compensation data collected may be useful in characterizing and improving laboratory salary structures and practices to better support workforce recruitment and retention.

  7. BSL-3 Laboratory Practices in the United States: Comparison of Select Agent and Non–Select Agent Facilities

    PubMed Central

    Pompei, Victoria C.; Anderson, Alice

    2014-01-01

    New construction of biosafety level 3 (BSL-3) laboratories in the United States has increased in the past decade to facilitate research on potential bioterrorism agents. The Centers for Disease Control and Prevention inspect BSL-3 facilities and review commissioning documentation, but no single agency has oversight over all BSL-3 facilities. This article explores the extent to which standard operating procedures in US BSL-3 facilities vary between laboratories with select agent or non–select agent status. Comparisons are made for the following variables: personnel training, decontamination, personal protective equipment (PPE), medical surveillance, security access, laboratory structure and maintenance, funding, and pest management. Facilities working with select agents had more complex training programs and decontamination procedures than non–select agent facilities. Personnel working in select agent laboratories were likely to use powered air purifying respirators, while non–select agent laboratories primarily used N95 respirators. More rigorous medical surveillance was carried out in select agent workers (although not required by the select agent program) and a higher level of restrictive access to laboratories was found. Most select agent and non–select agent laboratories reported adequate structural integrity in facilities; however, differences were observed in personnel perception of funding for repairs. Pest management was carried out by select agent personnel more frequently than non–select agent personnel. Our findings support the need to promote high quality biosafety training and standard operating procedures in both select agent and non–select agent laboratories to improve occupational health and safety. PMID:24552359

  8. Numerical Investigation of Earthquake Nucleation on a Laboratory-Scale Heterogeneous Fault with Rate-and-State Friction

    NASA Astrophysics Data System (ADS)

    Higgins, N.; Lapusta, N.

    2014-12-01

    Many large earthquakes on natural faults are preceded by smaller events, often termed foreshocks, that occur close in time and space to the larger event that follows. Understanding the origin of such events is important for understanding earthquake physics. Unique laboratory experiments of earthquake nucleation in a meter-scale slab of granite (McLaskey and Kilgore, 2013; McLaskey et al., 2014) demonstrate that sample-scale nucleation processes are also accompanied by much smaller seismic events. One potential explanation for these foreshocks is that they occur on small asperities - or bumps - on the fault interface, which may also be the locations of smaller critical nucleation size. We explore this possibility through 3D numerical simulations of a heterogeneous 2D fault embedded in a homogeneous elastic half-space, in an attempt to qualitatively reproduce the laboratory observations of foreshocks. In our model, the simulated fault interface is governed by rate-and-state friction with laboratory-relevant frictional properties, fault loading, and fault size. To create favorable locations for foreshocks, the fault surface heterogeneity is represented as patches of increased normal stress, decreased characteristic slip distance L, or both. Our simulation results indicate that one can create a rate-and-state model of the experimental observations. Models with a combination of higher normal stress and lower L at the patches are closest to matching the laboratory observations of foreshocks in moment magnitude, source size, and stress drop. In particular, we find that, when the local compression is increased, foreshocks can occur on patches that are smaller than theoretical critical nucleation size estimates. The additional inclusion of lower L for these patches helps to keep stress drops within the range observed in experiments, and is compatible with the asperity model of foreshock sources, since one would expect more compressed spots to be smoother (and hence have

  9. Analyses of rocks from the laboratory of the United States Geological Survey, 1880-1903

    USGS Publications Warehouse

    Clarke, F.W.

    1904-01-01

    The present Geological Survey of the United States was organized in 1879. In 1880 a chemical laboratory was established at Denver, in connection with the Colorado work, in charge of Dr. W. F. Hillebrand, with whom were associated Mr. Antony Guyard and, later, Mr. L. G. Eakins. In 1882 Dr. W. H. Melville was placed in charge of a second laboratory at San Francisco, and in the autumn of 1883 the central laboratory was started in Washington, with myself as chief chemist. In November, 1885, Doctor Hillebrand was transferred to Washington; early in 1888 he was followed by Mr. Eakins, and the Denver laboratory was discontinued. In the spring of 1890 Doctor Melville also was transferred to Washington, and since then the chemical work of the Survey has been concentrated at headquarters.Up to January 1, 1904, over 5,300 analyses have been made in the laboratory at Washington. These represent rocks, minerals, ores, waters, sediments, coals, metals, and so on through all the range of substances with which geology has to do. There were also some hundreds of analyses made in the laboratories at Denver and San Francisco. A fair amount of research work upon mineralogical and analytical problems has also been done. In all of this work the following chemists have been employed: E. T. Allen, Charles Catlett, T. M. Chatard, F. W. Clarke, L. G. Eakins, F. A. Gooch, Antony Guyard, W. F. Hillebrand, W. H. Melville, R. B. Riggs, W. T. Schaller, E. A. Schneider, George Steiger, H. N. Stokes, E. C. Sullivan, William Valentine, and J. E. Whitfield. As many as eight of these have been at work simultaneously; at present only six are connected with the Survey. Other officers of the Survey have been occupied more or less with chemical questions; but the men named in this list were connected directly with the laboratory. Some work for the chemical division has also been done by chemists not regularly on the rolls of the Survey; but their analyses, with the exception of a single group to be

  10. Finite-key security analysis of quantum key distribution with imperfect light sources

    DOE PAGES

    Mizutani, Akihiro; Curty, Marcos; Lim, Charles Ci Wen; ...

    2015-09-09

    In recent years, the gap between theory and practice in quantum key distribution (QKD) has been significantly narrowed, particularly for QKD systems with arbitrarily flawed optical receivers. The status for QKD systems with imperfect light sources is however less satisfactory, in the sense that the resulting secure key rates are often overly dependent on the quality of state preparation. This is especially the case when the channel loss is high. Very recently, to overcome this limitation, Tamaki et al proposed a QKD protocol based on the so-called 'rejected data analysis', and showed that its security in the limit of infinitelymore » long keys is almost independent of any encoding flaw in the qubit space, being this protocol compatible with the decoy state method. Here, as a step towards practical QKD, we show that a similar conclusion is reached in the finite-key regime, even when the intensity of the light source is unstable. More concretely, we derive security bounds for a wide class of realistic light sources and show that the bounds are also efficient in the presence of high channel loss. Our results strongly suggest the feasibility of long distance provably secure communication with imperfect light sources.« less

  11. 7 CFR 996.21 - USDA laboratory.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false USDA laboratory. 996.21 Section 996.21 Agriculture... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.21 USDA laboratory. USDA laboratory means laboratories of the Science and Technology Programs, Agricultural Marketing...

  12. 7 CFR 996.21 - USDA laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false USDA laboratory. 996.21 Section 996.21 Agriculture... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.21 USDA laboratory. USDA laboratory means laboratories of the Science and Technology Programs, Agricultural Marketing...

  13. 7 CFR 996.21 - USDA laboratory.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false USDA laboratory. 996.21 Section 996.21 Agriculture... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.21 USDA laboratory. USDA laboratory means laboratories of the Science and Technology Programs, Agricultural Marketing...

  14. 7 CFR 996.21 - USDA laboratory.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false USDA laboratory. 996.21 Section 996.21 Agriculture... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.21 USDA laboratory. USDA laboratory means laboratories of the Science and Technology Programs, Agricultural Marketing...

  15. 7 CFR 802.1 - Qualified laboratories.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 7 2011-01-01 2011-01-01 false Qualified laboratories. 802.1 Section 802.1... REQUIREMENTS FOR GRAIN WEIGHING EQUIPMENT AND RELATED GRAIN HANDLING SYSTEMS § 802.1 Qualified laboratories. (a) Metrology laboratories. (1) Any State metrology laboratory currently approved by the NBS ongoing...

  16. Security of quantum key distribution with multiphoton components

    PubMed Central

    Yin, Hua-Lei; Fu, Yao; Mao, Yingqiu; Chen, Zeng-Bing

    2016-01-01

    Most qubit-based quantum key distribution (QKD) protocols extract the secure key merely from single-photon component of the attenuated lasers. However, with the Scarani-Acin-Ribordy-Gisin 2004 (SARG04) QKD protocol, the unconditionally secure key can be extracted from the two-photon component by modifying the classical post-processing procedure in the BB84 protocol. Employing the merits of SARG04 QKD protocol and six-state preparation, one can extract secure key from the components of single photon up to four photons. In this paper, we provide the exact relations between the secure key rate and the bit error rate in a six-state SARG04 protocol with single-photon, two-photon, three-photon, and four-photon sources. By restricting the mutual information between the phase error and bit error, we obtain a higher secure bit error rate threshold of the multiphoton components than previous works. Besides, we compare the performances of the six-state SARG04 with other prepare-and-measure QKD protocols using decoy states. PMID:27383014

  17. [Errors in laboratory daily practice].

    PubMed

    Larrose, C; Le Carrer, D

    2007-01-01

    Legislation set by GBEA (Guide de bonne exécution des analyses) requires that, before performing analysis, the laboratory directors have to check both the nature of the samples and the patients identity. The data processing of requisition forms, which identifies key errors, was established in 2000 and in 2002 by the specialized biochemistry laboratory, also with the contribution of the reception centre for biological samples. The laboratories follow a strict criteria of defining acceptability as a starting point for the reception to then check requisition forms and biological samples. All errors are logged into the laboratory database and analysis report are sent to the care unit specifying the problems and the consequences they have on the analysis. The data is then assessed by the laboratory directors to produce monthly or annual statistical reports. This indicates the number of errors, which are then indexed to patient files to reveal the specific problem areas, therefore allowing the laboratory directors to teach the nurses and enable corrective action.

  18. KEY COMPARISON: CCEM.RF-K18.CL (GT-RF/00-1): Noise in 50 Ω coaxial line at frequencies up to 1 GHz

    NASA Astrophysics Data System (ADS)

    Eiø, Christopher; Adamson, David; Randa, James; Allal, Djamel; Uzdin, Rinadij

    2006-01-01

    A measurement comparison of noise temperature has been carried out between four national metrology laboratories in coaxial line at 30 MHz, 60 MHz and 1 GHz. The identification of this intercomparison is CCEM.RF-K18.CL. Two noise sources have been measured. The following four national laboratories participated in this intercomparison: NPL (United Kingdom), NIST (United States of America), BNM-LNE (France) and VNIIFTRI (Russia). The National Physical Laboratory (UK) acted as the pilot laboratory for the comparison. It can be seen that there is generally good agreement between the laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  19. Optimizing Requirements Decisions with KEYS

    NASA Technical Reports Server (NTRS)

    Jalali, Omid; Menzies, Tim; Feather, Martin

    2008-01-01

    Recent work with NASA's Jet Propulsion Laboratory has allowed for external access to five of JPL's real-world requirements models, anonymized to conceal proprietary information, but retaining their computational nature. Experimentation with these models, reported herein, demonstrates a dramatic speedup in the computations performed on them. These models have a well defined goal: select mitigations that retire risks which, in turn, increases the number of attainable requirements. Such a non-linear optimization is a well-studied problem. However identification of not only (a) the optimal solution(s) but also (b) the key factors leading to them is less well studied. Our technique, called KEYS, shows a rapid way of simultaneously identifying the solutions and their key factors. KEYS improves on prior work by several orders of magnitude. Prior experiments with simulated annealing or treatment learning took tens of minutes to hours to terminate. KEYS runs much faster than that; e.g for one model, KEYS ran 13,000 times faster than treatment learning (40 minutes versus 0.18 seconds). Processing these JPL models is a non-linear optimization problem: the fewest mitigations must be selected while achieving the most requirements. Non-linear optimization is a well studied problem. With this paper, we challenge other members of the PROMISE community to improve on our results with other techniques.

  20. 2015 Key Water Power Program and National Laboratory Accomplishments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Office of Energy Efficiency and Renewable Energy

    The U.S. Department of Energy Water Power Program is committed to developing and deploying a portfolio of innovative technologies and market solutions for clean, domestic power generation from water resources across the United States.

  1. Corrective Action Plan in response to the March 1992 Tiger Team Assessment of the Ames Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-11-20

    On March 5, 1992, a Department of Energy (DOE) Tiger Team completed an assessment of the Ames Laboratory, located in Ames, Iowa. The purpose of the assessment was to provide the Secretary of Energy with a report on the status and performance of Environment, Safety and Health (ES H) programs at Ames Laboratory. Detailed findings of the assessment are presented in the report, DOE/EH-0237, Tiger Team Assessment of the Ames Laboratory. This document, the Ames Laboratory Corrective Action Plan (ALCAP), presents corrective actions to overcome deficiencies cited in the Tiger Team Assessment. The Tiger Team identified 53 Environmental findings, frommore » which the Team derived four key findings. In the Safety and Health (S H) area, 126 concerns were identified, eight of which were designated Category 11 (there were no Category I concerns). Seven key concerns were derived from the 126 concerns. The Management Subteam developed 19 findings which have been summarized in four key findings. The eight S H Category 11 concerns identified in the Tiger Team Assessment were given prompt management attention. Actions to address these deficiencies have been described in individual corrective action plans, which were submitted to DOE Headquarters on March 20, 1992. The ALCAP includes actions described in this early response, as well as a long term strategy and framework for correcting all remaining deficiencies. Accordingly, the ALCAP presents the organizational structure, management systems, and specific responses that are being developed to implement corrective actions and to resolve root causes identified in the Tiger Team Assessment. The Chicago Field Office (CH), IowaState University (ISU), the Institute for Physical Research and Technology (IPRT), and Ames Laboratory prepared the ALCAP with input from the DOE Headquarters, Office of Energy Research (ER).« less

  2. Corrective Action Plan in response to the March 1992 Tiger Team Assessment of the Ames Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-11-20

    On March 5, 1992, a Department of Energy (DOE) Tiger Team completed an assessment of the Ames Laboratory, located in Ames, Iowa. The purpose of the assessment was to provide the Secretary of Energy with a report on the status and performance of Environment, Safety and Health (ES&H) programs at Ames Laboratory. Detailed findings of the assessment are presented in the report, DOE/EH-0237, Tiger Team Assessment of the Ames Laboratory. This document, the Ames Laboratory Corrective Action Plan (ALCAP), presents corrective actions to overcome deficiencies cited in the Tiger Team Assessment. The Tiger Team identified 53 Environmental findings, from whichmore » the Team derived four key findings. In the Safety and Health (S&H) area, 126 concerns were identified, eight of which were designated Category 11 (there were no Category I concerns). Seven key concerns were derived from the 126 concerns. The Management Subteam developed 19 findings which have been summarized in four key findings. The eight S&H Category 11 concerns identified in the Tiger Team Assessment were given prompt management attention. Actions to address these deficiencies have been described in individual corrective action plans, which were submitted to DOE Headquarters on March 20, 1992. The ALCAP includes actions described in this early response, as well as a long term strategy and framework for correcting all remaining deficiencies. Accordingly, the ALCAP presents the organizational structure, management systems, and specific responses that are being developed to implement corrective actions and to resolve root causes identified in the Tiger Team Assessment. The Chicago Field Office (CH), IowaState University (ISU), the Institute for Physical Research and Technology (IPRT), and Ames Laboratory prepared the ALCAP with input from the DOE Headquarters, Office of Energy Research (ER).« less

  3. 40 CFR 141.705 - Approved laboratories.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...

  4. 40 CFR 141.705 - Approved laboratories.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...

  5. 40 CFR 141.705 - Approved laboratories.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...

  6. 40 CFR 141.705 - Approved laboratories.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...

  7. 40 CFR 141.705 - Approved laboratories.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Cryptosporidium analysis by an equivalent State laboratory certification program. (b) E. coli. Any laboratory... coliform or fecal coliform analysis under § 141.74 is approved for E. coli analysis under this subpart when the laboratory uses the same technique for E. coli that the laboratory uses for § 141.74. (c...

  8. Commercialization of a DOE Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stephenson, Barry A.

    2008-01-15

    On April 1, 1998, Materials and Chemistry Laboratory, Inc. (MCLinc) began business as an employee-owned, commercial, applied research laboratory offering services to both government and commercial clients. The laboratory had previously been a support laboratory to DoE's gaseous diffusion plant in Oak Ridge (K-25). When uranium enrichment was halted at the site, the laboratory was expanded to as an environmental demonstration center and served from 1992 until 1997 as a DOE Environmental User Facility. In 1997, after the laboratory was declared surplus, it was made available to the employee group who operated the laboratory for DOE as a government-owned, contractor-operatedmore » facility. This paper describes briefly the process of establishing the business. Attributes that contributed to the success of MCLinc are described. Some attention is given to lessons learned and to changes that could facilitate future attempts to make similar transitions. Lessons learnt: as with any business venture, operation over time has revealed that some actions taken by the laboratory founders have contributed to its successful operation while others were not so successful. Observations are offered in hopes that lessons learned may suggest actions that will facilitate future attempts to make similar transitions. First, the decision to vest significant ownership of the business in the core group of professionals operating the business is key to its success. Employee-owners of the laboratory have consistently provided a high level of service to its customers while conducting business in a cost-efficient manner. Secondly, an early decision to provide business support services in-house rather than purchasing them from support contractors on site have proven cost-effective. Laboratory employees do multiple tasks and perform overhead tasks in addition to their chargeable technical responsibilities. Thirdly, assessment of technical capabilities in view of market needs and a decision to

  9. Lawrence Berkeley National Laboratory 2015 Annual Financial Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, Kim, P

    FY2015 financial results reflect a year of significant scientific, operational and financial achievement for Lawrence Berkeley National Laboratory. Complementing many scientific accomplishments, Berkeley Lab completed construction of four new research facilities: the General Purpose Laboratory, Chu Hall, Wang Hall and the Flexlab Building Efficiency Testbed. These state-of-the-art facilities allow for program growth and enhanced collaboration, in part by enabling programs to return to the Lab’s Hill Campus from offsite locations. Detailed planning began for the new Integrative Genomics Building (IGB) that will house another major program currently located offsite. Existing site infrastructure was another key focus area. The Lab prioritizedmore » and increased investments in deferred maintenance in alignment with the Berkeley Lab Infrastructure Plan, which was developed under the leadership of the DOE Office of Science. With the expiration of American Recovery and Reinvestment Act (ARRA) funds, we completed the close-out of all of our 134 ARRA projects, recording total costs of $331M over the FY2009-2015 period. Download the report to read more.« less

  10. Laboratory considerations of United States Pharmacopeia Chapter <71> sterility tests and its application to pharmaceutical compounding.

    PubMed

    Hyde, Tiffany D

    2014-01-01

    The purpose of this article is to describe United States Pharmacopeia Chapter <71> Sterility Tests from the perspective of Current Good Manufacturing Practices in order to aid compounding pharmacists in understanding the details and complexities that are required. Compounding pharmacists face a unique challenge in the industry today, with their compounding practice and the U.S. Food and Drug Administration trying to impose Current Good Manufacturing Practices guidelines. Naturally, this becomes a challenge to contract testing laboratories as well, as they are caught between the testing for non-Current Good Manufacturing Practices compounding standards and Current Good Manufacturing Practices manufacturing. It is important that the compounding pharmacist and their partner testing laboratory work closely together to ensure appropriate requirements are being met.

  11. 7 CFR 996.22 - USDA-approved laboratory.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.22 USDA-approved laboratory. USDA-approved laboratory means laboratories approved by the Science and Technology Programs...

  12. [How to Interpret and Use Routine Laboratory Data--Our Methods to Interpret Routine Laboratory Data--Chairmen's Introductory Remarks].

    PubMed

    Honda, Takayuki; Tozuka, Minoru

    2015-09-01

    In the reversed clinicopathological conference (R-CPC), three specialists in laboratory medicine interpreted routine laboratory data independently in order to understand the detailed state of a patient. R-CPC is an educational method to use laboratory data appropriately, and it is also important to select differential diagnoses in a process of clinical reasoning in addition to the present illness and physical examination. Routine laboratory tests can be performed repeatedly at a relatively low cost, and their time-series analysis can be performed. Interpretation of routine laboratory data is almost the same as taking physical findings. General findings are initially checked and then the state of each organ is examined. Although routine laboratory tests cost little, we can gain much more information from them about the patient than physical examinations.

  13. Consolidated clinical microbiology laboratories.

    PubMed

    Sautter, Robert L; Thomson, Richard B

    2015-05-01

    The manner in which medical care is reimbursed in the United States has resulted in significant consolidation in the U.S. health care system. One of the consequences of this has been the development of centralized clinical microbiology laboratories that provide services to patients receiving care in multiple off-site, often remote, locations. Microbiology specimens are unique among clinical specimens in that optimal analysis may require the maintenance of viable organisms. Centralized laboratories may be located hours from patient care settings, and transport conditions need to be such that organism viability can be maintained under a variety of transport conditions. Further, since the provision of rapid results has been shown to enhance patient care, effective and timely means for generating and then reporting the results of clinical microbiology analyses must be in place. In addition, today, increasing numbers of patients are found to have infection caused by pathogens that were either very uncommon in the past or even completely unrecognized. As a result, infectious disease specialists, in particular, are more dependent than ever on access to high-quality diagnostic information from clinical microbiology laboratories. In this point-counterpoint discussion, Robert Sautter, who directs a Charlotte, NC, clinical microbiology laboratory that provides services for a 40-hospital system spread over 3 states in the southeastern United States explains how an integrated clinical microbiology laboratory service has been established in a multihospital system. Richard (Tom) Thomson of the NorthShore University HealthSystem in Evanston, IL, discusses some of the problems and pitfalls associated with large-scale laboratory consolidation. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  14. A method for developing outcome measures in the clinical laboratory.

    PubMed

    Jones, J

    1996-01-01

    Measuring and reporting outcomes in health care is becoming more important for quality assessment, utilization assessment, accreditation standards, and negotiating contracts in managed care. How does one develop an outcome measure for the laboratory to assess the value of the services? A method is described which outlines seven steps in developing outcome measures for a laboratory service or process. These steps include the following: 1. Identify the process or service to be monitored for performance and outcome assessment. 2. If necessary, form an multidisciplinary team of laboratory staff, other department staff, physicians, and pathologists. 3. State the purpose of the test or service including a review of published data for the clinical pathological correlation. 4. Prepare a process cause and effect diagram including steps critical to the outcome. 5. Identify key process variables that contribute to positive or negative outcomes. 6. Identify outcome measures that are not process measures. 7. Develop an operational definition, identify data sources, and collect data. Examples, including a process cause and effect diagram, process variables, and outcome measures, are given using the Therapeutic Drug Monitoring service (TDM). A summary of conclusions and precautions for outcome measurement is then provided.

  15. Nanotechnology Characterization Laboratory Unveils New Technical Services for Drug Developers | Frederick National Laboratory for Cancer Research

    Cancer.gov

    FREDERICK, Md. -- Drug developers now have access to a shared analytical technology, developed and provided by the Frederick National Laboratory for Cancer Research, that helps fine-tune nanomedicine formulations and overcomes a key hurdle on the pat

  16. Experimental quantum key distribution with source flaws

    NASA Astrophysics Data System (ADS)

    Xu, Feihu; Wei, Kejin; Sajeed, Shihan; Kaiser, Sarah; Sun, Shihai; Tang, Zhiyuan; Qian, Li; Makarov, Vadim; Lo, Hoi-Kwong

    2015-09-01

    Decoy-state quantum key distribution (QKD) is a standard technique in current quantum cryptographic implementations. Unfortunately, existing experiments have two important drawbacks: the state preparation is assumed to be perfect without errors and the employed security proofs do not fully consider the finite-key effects for general attacks. These two drawbacks mean that existing experiments are not guaranteed to be proven to be secure in practice. Here, we perform an experiment that shows secure QKD with imperfect state preparations over long distances and achieves rigorous finite-key security bounds for decoy-state QKD against coherent attacks in the universally composable framework. We quantify the source flaws experimentally and demonstrate a QKD implementation that is tolerant to channel loss despite the source flaws. Our implementation considers more real-world problems than most previous experiments, and our theory can be applied to general discrete-variable QKD systems. These features constitute a step towards secure QKD with imperfect devices.

  17. Developing laboratory networks: a practical guide and application.

    PubMed

    Kirk, Carol J; Shult, Peter A

    2010-01-01

    The role of the public health laboratory (PHL) in support of public health response has expanded beyond testing to include a number of other core functions, such as emergency response, training and outreach, communications, laboratory-based surveillance, and laboratory data management. These functions can only be accomplished by a network that includes public health and other agency laboratories and clinical laboratories. It is a primary responsibility of the PHL to develop and maintain such a network. In this article, we present practical recommendations-based on 17 years of network development experience-for the development of statewide laboratory networks. These recommendations, and examples of current laboratory networks, are provided to facilitate laboratory network development in other states. The development of laboratory networks will enhance each state's public health system and is critical to the development of a robust national Laboratory Response Network.

  18. The makeover of the Lakeshore General Hospital laboratories.

    PubMed

    Estioko-Taimuri, Teresa

    2006-01-31

    This article describes the expansion and reorganization of a moderate-sized Canadian laboratory from Day One to "Live Day." The key factors to the success of this project were organized planning by the laboratory staff and the introduction of core lab theories, team building, and organized training sessions. The successful makeover resulted in improved turnaround time for STAT tests, especially those coming from the Emergency Unit. The efforts of the laboratory personnel toward the improvement of laboratory services, in spite of budget, human resources constraints, and resistance to change, are addressed.

  19. United States Air Force Summer Research Program -- 1993. Volume 16. Arnold Engineering Development Center. Frank J. Seiler Research Laboratory. Wilford Hall Medical Center

    DTIC Science & Technology

    1993-12-01

    A I 7f t UNITED STATE AIR FORCE SUMMER RESEARCH PROGRAM -- 1993 SUMMER RESEARCH PROGRAM FINAL REPORTS VOLUME 16 ARNOLD ENGINEERING DEVELOPMENT CENTER...FRANK J. SELLER RESEARCH LABORATORY WILFORD HALL MEDICAL CENTER RESEARCH & DEVELOPMENT LABORATORIES 5800 Uplander Way Culver City, CA 90230-6608...National Rd. Vol-Page No: 15-44 Dist Tecumseh High School 8.4 New Carlisle, OH 45344-0000 Barber, Jason Laboratory: AL/CF 1000 10th St. Vol-Page No

  20. Assessing Student Learning in a Virtual Laboratory Environment

    ERIC Educational Resources Information Center

    Wolf, T.

    2010-01-01

    Laboratory experience is a key factor in technical and scientific education. Virtual laboratories have been proposed to reduce cost and simplify maintenance of lab facilities while still providing students with access to real systems. It is important to determine if such virtual labs are still effective for student learning. In the assessment of a…

  1. Key comparison of liquid density standards

    NASA Astrophysics Data System (ADS)

    Buchner, Christian; Zelenka, Zoltan; Kajastie, Heikki; Madec, Tanguy; Wolf, Henning; Vámossy, Csilla; Lorefice, Salvatore; Garberg, Torgunn; Lenard, Elżbieta; Spohr, Isabel; Mares, Gabriela; Spurný, Robert; Lumbreras, Angel; Medina, Nieves; Y Akçadağ, Ümit; Perkin, Michael

    2015-01-01

    Hydrostatic density determination for liquids is mainly performed by laboratories to provide means for calibrating liquid density measuring instruments such as oscillation-type density meters. From 2002 to 2005 the CIPM key comparison CCM.D-K2 'comparison of liquid density standards' was carried out piloted by the PTB. The aim was to compare the results of the density determination by the participating laboratories to support entries to the CMC tables in this sub-field. To provide further laboratories the possibility to support their entries to the CMC tables at the meeting of the EUROMET Working Group on Density in 2007 this comparison was agreed on. BEV (Austria) organized the comparison supported by the PTB (Germany). For the comparison samples of pentadecane, water, tetrachloroethylene and of an oil of high viscosity were measured in the temperature range from 5 °C to 60 °C at atmospheric pressure by hydrostatic weighing. The measurements were completed in 2008. The reference values of the first reports based on the draft of the CCM.D-K2. After the official publication of the CCM.D-K2 the reference values were recalculated and the report was finalised in 2015. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Communication Is Key to Common Core

    ERIC Educational Resources Information Center

    Maunsell, Patricia A.

    2014-01-01

    States, districts, and schools must work to develop effective implementation and communications plans around the Common Core State Standards and aligned assessments. The Education Trust commissioned research on the communication of changes to state assessments in the recent past and lessons learned from that effort identify key elements of an…

  3. Grid Modernization Laboratory Consortium - Testing and Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroposki, Benjamin; Skare, Paul; Pratt, Rob

    This paper highlights some of the unique testing capabilities and projects being performed at several national laboratories as part of the U. S. Department of Energy Grid Modernization Laboratory Consortium. As part of this effort, the Grid Modernization Laboratory Consortium Testing Network isbeing developed to accelerate grid modernization by enablingaccess to a comprehensive testing infrastructure and creating a repository of validated models and simulation tools that will be publicly available. This work is key to accelerating thedevelopment, validation, standardization, adoption, and deployment of new grid technologies to help meet U. S. energy goals.

  4. Laboratory Modelling of Volcano Plumbing Systems: a review

    NASA Astrophysics Data System (ADS)

    Galland, Olivier; Holohan, Eoghan P.; van Wyk de Vries, Benjamin; Burchardt, Steffi

    2015-04-01

    Earth scientists have, since the XIX century, tried to replicate or model geological processes in controlled laboratory experiments. In particular, laboratory modelling has been used study the development of volcanic plumbing systems, which sets the stage for volcanic eruptions. Volcanic plumbing systems involve complex processes that act at length scales of microns to thousands of kilometres and at time scales from milliseconds to billions of years, and laboratory models appear very suitable to address them. This contribution reviews laboratory models dedicated to study the dynamics of volcano plumbing systems (Galland et al., Accepted). The foundation of laboratory models is the choice of relevant model materials, both for rock and magma. We outline a broad range of suitable model materials used in the literature. These materials exhibit very diverse rheological behaviours, so their careful choice is a crucial first step for the proper experiment design. The second step is model scaling, which successively calls upon: (1) the principle of dimensional analysis, and (2) the principle of similarity. The dimensional analysis aims to identify the dimensionless physical parameters that govern the underlying processes. The principle of similarity states that "a laboratory model is equivalent to his geological analogue if the dimensionless parameters identified in the dimensional analysis are identical, even if the values of the governing dimensional parameters differ greatly" (Barenblatt, 2003). The application of these two steps ensures a solid understanding and geological relevance of the laboratory models. In addition, this procedure shows that laboratory models are not designed to exactly mimic a given geological system, but to understand underlying generic processes, either individually or in combination, and to identify or demonstrate physical laws that govern these processes. From this perspective, we review the numerous applications of laboratory models to

  5. 7 CFR 996.22 - USDA-approved laboratory.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 8 2013-01-01 2013-01-01 false USDA-approved laboratory. 996.22 Section 996.22... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.22 USDA-approved laboratory. USDA-approved laboratory means laboratories approved by the Science and Technology Programs...

  6. 7 CFR 996.22 - USDA-approved laboratory.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 8 2012-01-01 2012-01-01 false USDA-approved laboratory. 996.22 Section 996.22... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.22 USDA-approved laboratory. USDA-approved laboratory means laboratories approved by the Science and Technology Programs...

  7. 7 CFR 996.22 - USDA-approved laboratory.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 8 2014-01-01 2014-01-01 false USDA-approved laboratory. 996.22 Section 996.22... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.22 USDA-approved laboratory. USDA-approved laboratory means laboratories approved by the Science and Technology Programs...

  8. 7 CFR 996.22 - USDA-approved laboratory.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 8 2011-01-01 2011-01-01 false USDA-approved laboratory. 996.22 Section 996.22... STANDARDS FOR DOMESTIC AND IMPORTED PEANUTS MARKETED IN THE UNITED STATES Definitions § 996.22 USDA-approved laboratory. USDA-approved laboratory means laboratories approved by the Science and Technology Programs...

  9. Geology and hydrogeology of the Florida Keys

    USGS Publications Warehouse

    Halley, Robert B.; Vacher, H. L.; Shinn,

    1997-01-01

    This chapter discusses the geology and hydrogeology of the Florida Keys, and focuses on the islands formed of Pleistocene limestone. These islands, which are crossed when driving from Miami to Key West, are typically regarded as "the Florida Keys." The outstanding and fragile character of ecosystems on and around the Florida Keys has prompted State and Federal efforts to protect and preserve the remaining public portions of the region. The Florida Keys were largely ignored during the sixteenth, seventeenth, and eighteenth centuries, although the waters just offshore provided a major shipping thoroughfare to and from the New World. The Florida Keys are now recognized as one of the great recreational and environmental resources of the United States. The islands are outposts of a laid-back, tropical resort culture that has as its foundation warmth and clear water. A significant part of the attraction is fishing, diving, and boating around the area's coral reefs, which the islands protect. But the reefs were not always so highly valued. The Florida Keys that have protected the reefs for millennia, may now be the source of the agents that may accomplish what Agassiz thought was beyond man's power a century ago.

  10. Key performance indicators score (KPIs-score) based on clinical and laboratorial parameters can establish benchmarks for internal quality control in an ART program.

    PubMed

    Franco, José G; Petersen, Claudia G; Mauri, Ana L; Vagnini, Laura D; Renzi, Adriana; Petersen, Bruna; Mattila, M C; Comar, Vanessa A; Ricci, Juliana; Dieamant, Felipe; Oliveira, João Batista A; Baruffi, Ricardo L R

    2017-06-01

    KPIs have been employed for internal quality control (IQC) in ART. However, clinical KPIs (C-KPIs) such as age, AMH and number of oocytes collected are never added to laboratory KPIs (L-KPIs), such as fertilization rate and morphological quality of the embryos for analysis, even though the final endpoint is the evaluation of clinical pregnancy rates. This paper analyzed if a KPIs-score strategy with clinical and laboratorial parameters could be used to establish benchmarks for IQC in ART cycles. In this prospective cohort study, 280 patients (36.4±4.3years) underwent ART. The total KPIs-score was obtained by the analysis of age, AMH (AMH Gen II ELISA/pre-mixing modified, Beckman Coulter Inc.), number of metaphase-II oocytes, fertilization rates and morphological quality of the embryonic lot. The total KPIs-score (C-KPIs+L-KPIs) was correlated with the presence or absence of clinical pregnancy. The relationship between the C-KPIs and L-KPIs scores was analyzed to establish quality standards, to increase the performance of clinical and laboratorial processes in ART. The logistic regression model (LRM), with respect to pregnancy and total KPIs-score (280 patients/102 clinical pregnancies), yielded an odds ratio of 1.24 (95%CI = 1.16-1.32). There was also a significant difference (p<0.0001) with respect to the total KPIs-score mean value between the group of patients with clinical pregnancies (total KPIs-score=20.4±3.7) and the group without clinical pregnancies (total KPIs-score=15.9±5). Clinical pregnancy probabilities (CPP) can be obtained using the LRM (prediction key) with the total KPIs-score as a predictor variable. The mean C-KPIs and L-KPIs scores obtained in the pregnancy group were 11.9±2.9 and 8.5±1.7, respectively. Routinely, in all cases where the C-KPIs score was ≥9, after the procedure, the L-KPIs score obtained was ≤6, a revision of the laboratory procedure was performed to assess quality standards. This total KPIs-score could set up

  11. EURAMET.T-K7 Key Comparison of Water Triple-Point Cells

    NASA Astrophysics Data System (ADS)

    Peruzzi, A.; Bosma, R.; Kerkhof, O.; Rosenkranz, P.; Del Campo Maldonado, M. D.; Strnad, R.; Nielsen, J.; Anagnostou, M.; Veliki, T.; Zvizdic, D.; Grudnewicz, E.; Nedea, M.; Neagu, D. M.; Steur, P.; Filipe, E.; Lobo, I.; Antonsen, I.; Renaot, E.; Heinonen, M.; Weckstrom, T.; Bojkovski, J.; Turzo-Andras, E.; Nemeth, S.; White, M.; Tegeler, E.; Dobre, M.; Duris, S.; Kartal Dogan, A.; Uytun, A.; Augevicius, V.; Pauzha, A.; Pokhodun, A.; Simic, S.

    2011-12-01

    The results of a EURAMET key comparison of water triple-point cells (EURAMET.T-K7) are reported. The equipment used, the measuring conditions applied, and the procedures adopted for the water triple-point measurement at the participating laboratories are synthetically presented. The definitions of the national reference for the water triple-point temperature adopted by each laboratory are disclosed. The multiplicity of degrees of equivalence arising for the linking laboratories with respect to the "mother" comparison CCT-K7 is discussed in detail.

  12. Senior Laboratory Animal Technician | Center for Cancer Research

    Cancer.gov

    PROGRAM DESCRIPTION The Laboratory Animal Sciences Program (LASP) provides exceptional quality animal care and technical support services for animal research performed at the National Cancer Institute at the Frederick National Laboratory for Cancer Research. LASP executes this mission by providing a broad spectrum of state-of-the-art technologies and services that are focused on the design, generation, characterization and application of genetically engineered and biological animal models of human disease, which are aimed at the development of targeted diagnostics and therapies. LASP contributes to advancing human health, developing new treatments, and improving existing treatments for cancer and other diseases while ensuring safe and humane treatment of animals. KEY ROLES/RESPONSIBILITIES The Senior Laboratory Animal Technician will be responsible for: Daily tasks associated with the care, breeding and treatment of research animals for experimental purposes Management of rodent breeding colonies consisting of multiple, genetically complex strains and associated record keeping and database management Colony management procedures including: tail clipping, animal identification, weaning Data entry consistent with complex colony management Collection of routine diagnostic samples Coordinating shipment of live animals and specimens Performing rodent experimental procedures including basic necropsy and blood collection Observation and recording of physical signs of animal health Knowledge of safe working practices using chemical carcinogen and biological hazards Work schedule may include weekend and holiday hours This position is in support of the Center for Cancer Research (CCR).

  13. 21 CFR 225.158 - Laboratory assays.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Laboratory assays. 225.158 Section 225.158 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory assays. Where the results of laboratory assays of drug components, including assays by State feed...

  14. 21 CFR 225.158 - Laboratory assays.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Laboratory assays. 225.158 Section 225.158 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS... Laboratory assays. Where the results of laboratory assays of drug components, including assays by State feed...

  15. 1995 Laboratory-Directed Research and Development Annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cauffman, D.P.; Shoaf, D.L.; Hill, D.A.

    1995-12-31

    The Laboratory-Directed Research and Development Program (LDRD) is a key component of the discretionary research conducted by Lockheed Idaho Technologies Company (Lockheed Idaho) at the Idaho National Engineering Laboratory (INEL). The threefold purpose and goal of the LDRD program is to maintain the scientific and technical vitality of the INEL, respond to and support new technical opportunities, and enhance the agility and flexibility of the national laboratory and Lockheed Idaho to address the current and future missions of the Department of Energy.

  16. Pricing and components analysis of some key essential pediatric medicine in Odisha state

    PubMed Central

    Samal, Satyajit; Swain, Trupti Rekha

    2017-01-01

    Objective: Study highlighting prices, i.e., the patients actually pay at ground level is important for interventions such as alternate procurement schemes or to expedite regulatory assessment of essential medicines for children. The present study was undertaken to study pricing and component analysis of few key essential medicines in Odisha state. Methodology: Six child-specific medicines of different formulations were selected based on use in different disease condition and having widest pricing variation. Data were collected, entered, and analyzed in the price components data collection form of the World Health Organization-Health Action International (WHO-HAI) 2007 Workbook version 5 – Part II provided as part of the WHO/HAI methodology. The analysis includes the cumulative percent markup, total cumulative percent markup, and percent contribution of individual components to the final medicine price in both public and private sector of Odisha state. Results: Add-on costs such as taxes, wholesale, and retail markups contribute substantially to the final price of medicines in private sector, particularly for branded-generic products. The largest contributor to add-on costs is at the level of retailer shop. Conclusion: Policy should be framed to achieve a greater transparency and uniformity of the pricing of medicines at different health sectors of Odisha. PMID:28458429

  17. Pricing and components analysis of some key essential pediatric medicine in Odisha state.

    PubMed

    Samal, Satyajit; Swain, Trupti Rekha

    2017-01-01

    Study highlighting prices, i.e., the patients actually pay at ground level is important for interventions such as alternate procurement schemes or to expedite regulatory assessment of essential medicines for children. The present study was undertaken to study pricing and component analysis of few key essential medicines in Odisha state. Six child-specific medicines of different formulations were selected based on use in different disease condition and having widest pricing variation. Data were collected, entered, and analyzed in the price components data collection form of the World Health Organization-Health Action International (WHO-HAI) 2007 Workbook version 5 - Part II provided as part of the WHO/HAI methodology. The analysis includes the cumulative percent markup, total cumulative percent markup, and percent contribution of individual components to the final medicine price in both public and private sector of Odisha state. Add-on costs such as taxes, wholesale, and retail markups contribute substantially to the final price of medicines in private sector, particularly for branded-generic products. The largest contributor to add-on costs is at the level of retailer shop. Policy should be framed to achieve a greater transparency and uniformity of the pricing of medicines at different health sectors of Odisha.

  18. Continuous variable quantum key distribution: finite-key analysis of composable security against coherent attacks.

    PubMed

    Furrer, F; Franz, T; Berta, M; Leverrier, A; Scholz, V B; Tomamichel, M; Werner, R F

    2012-09-07

    We provide a security analysis for continuous variable quantum key distribution protocols based on the transmission of two-mode squeezed vacuum states measured via homodyne detection. We employ a version of the entropic uncertainty relation for smooth entropies to give a lower bound on the number of secret bits which can be extracted from a finite number of runs of the protocol. This bound is valid under general coherent attacks, and gives rise to keys which are composably secure. For comparison, we also give a lower bound valid under the assumption of collective attacks. For both scenarios, we find positive key rates using experimental parameters reachable today.

  19. A national and state profile of leading health problems and health care quality for US children: key insurance disparities and across-state variations.

    PubMed

    Bethell, Christina D; Kogan, Michael D; Strickland, Bonnie B; Schor, Edward L; Robertson, Julie; Newacheck, Paul W

    2011-01-01

    Parent/consumer-reported data is valuable and necessary for population-based assessment of many key child health and health care quality measures relevant to both the Children's Health Insurance Program Reauthorization Act (CHIPRA) of 2009 and the Patient Protection and Affordable Care Act of 2010 (ACA). The aim of this study was to evaluate national and state prevalence of health problems and special health care needs in US children; to estimate health care quality related to adequacy and consistency of insurance coverage, access to specialist, mental health and preventive medical and dental care, developmental screening, and whether children meet criteria for having a medical home, including care coordination and family centeredness; and to assess differences in health and health care quality for children by insurance type, special health care needs status, race/ethnicity, and/or state of residence. National and state level estimates were derived from the 2007 National Survey of Children's Health (N = 91,642; children aged 0-17 years). Variations between children with public versus private sector health insurance, special health care needs, specific conditions, race/ethnicity, and across states were evaluated using multivariate logistic regression and/or standardized statistical tests. An estimated 43% of US children (32 million) currently have at least 1 of 20 chronic health conditions assessed, increasing to 54.1% when overweight, obesity, or being at risk for developmental delays are included; 19.2% (14.2 million) have conditions resulting in a special health care need, a 1.6 point increase since 2003. Compared with privately insured children, the prevalence, complexity, and severity of health problems were systematically greater for the 29.1% of all children who are publicly insured children after adjusting for variations in demographic and socioeconomic factors. Forty-five percent of all children in the United States scored positively on a minimal quality

  20. Laboratory Manual, Electrical Engineering 25.

    ERIC Educational Resources Information Center

    Syracuse Univ., NY. Dept. of Electrical Engineering.

    Developed as part of a series of materials in the electrical engineering sequence developed under contract with the United States Office of Education, this laboratory manual provides nine laboratory projects suitable for a second course in electrical engineering. Dealing with resonant circuits, electrostatic fields, magnetic devices, and…

  1. Asparagine 285 plays a key role in transition state stabilization in rabbit muscle creatine kinase

    PubMed Central

    Borders, Charles L.; MacGregor, Katherine M.; Edmiston, Paul L.; Gbeddy, Elikem R.K.; Thomenius, Michael J.; Mulligan, Guy B.; Snider, Mark J.

    2003-01-01

    To explore the possibility that asparagine 285 plays a key role in transition state stabilization in phosphagen kinase catalysis, the N285Q, N285D, and N285A site-directed mutants of recombinant rabbit muscle creatine kinase (rmCK) were prepared and characterized. Kinetic analysis of phosphocreatine formation showed that the catalytic efficiency of each N285 mutant was reduced by approximately four orders of magnitude, with the major cause of activity loss being a reduction in kcat in comparison to the recombinant native CK. The data for N285Q still fit a random-order, rapid-equilibrium mechanism, with either MgATP or creatine binding first with affinities very nearly equal to those for native CK. However, the affinity for the binding of the second substrate is reduced approximately 10-fold, suggesting that addition of a single methylene group at position 285 disrupts the symphony of substrate binding. The data for the N285A mutant only fit an ordered binding mechanism, with MgATP binding first. Isosteric replacement to form the N285D mutant has almost no effect on the KM values for either creatine or MgATP, thus the decrease in activity is due almost entirely to a 5000-fold reduction in kcat. Using the quenching of the intrinsic CK tryptophan fluorescence by added MgADP (Borders et al. 2002), it was found that, unlike native CK, none of the mutants have the ability to form a quaternary TSAC. We use these data to propose that asparagine 285 indeed plays a key role in transition state stabilization in the reaction catalyzed by creatine kinase and other phosphagen kinases. PMID:12592023

  2. Asparagine 285 plays a key role in transition state stabilization in rabbit muscle creatine kinase.

    PubMed

    Borders, Charles L; MacGregor, Katherine M; Edmiston, Paul L; Gbeddy, Elikem R K; Thomenius, Michael J; Mulligan, Guy B; Snider, Mark J

    2003-03-01

    To explore the possibility that asparagine 285 plays a key role in transition state stabilization in phosphagen kinase catalysis, the N285Q, N285D, and N285A site-directed mutants of recombinant rabbit muscle creatine kinase (rmCK) were prepared and characterized. Kinetic analysis of phosphocreatine formation showed that the catalytic efficiency of each N285 mutant was reduced by approximately four orders of magnitude, with the major cause of activity loss being a reduction in k(cat) in comparison to the recombinant native CK. The data for N285Q still fit a random-order, rapid-equilibrium mechanism, with either MgATP or creatine binding first with affinities very nearly equal to those for native CK. However, the affinity for the binding of the second substrate is reduced approximately 10-fold, suggesting that addition of a single methylene group at position 285 disrupts the symphony of substrate binding. The data for the N285A mutant only fit an ordered binding mechanism, with MgATP binding first. Isosteric replacement to form the N285D mutant has almost no effect on the K(M) values for either creatine or MgATP, thus the decrease in activity is due almost entirely to a 5000-fold reduction in k(cat). Using the quenching of the intrinsic CK tryptophan fluorescence by added MgADP (Borders et al. 2002), it was found that, unlike native CK, none of the mutants have the ability to form a quaternary TSAC. We use these data to propose that asparagine 285 indeed plays a key role in transition state stabilization in the reaction catalyzed by creatine kinase and other phosphagen kinases.

  3. Postdoctoral Professional Fellowships in Laboratory Medicine.

    PubMed

    Straseski, Joely A

    2013-04-01

    Doctoral level scientists often pursue a traditional academic route, focusing their efforts on research and education. However, additional options exist for those that are interested in using their laboratory and research skills in a clinical setting. Clinical laboratory directors serve as the interface between the clinical laboratory and the users of laboratory test results. This article describes these career paths options for PhD scientists. Clinical laboratory directors are primarily trained via one of two routes: physicians that have been trained in clinical pathology or non-physician doctoral scientists that have completed professional fellowship training. This article will focus on the latter of these 2 routes. In the United States, completing a postdoctoral fellowship in laboratory-specific professional fields qualifies non-physician doctoral scientists as laboratory directors and consultants. Their expert consultation provides invaluable insight into testing procedures such as possible sources of interference or inaccurate test results, preferred testing for specific clinical situations, and confirmatory methods. They must also be knowledgeable about current instrumentation, assay limitations, and the newest available technologies. One of the older and more developed professional fellowships in the United States, clinical chemistry, encompasses many laboratory disciplines and will be highlighted in detail. Training information specific to clinical immunology, clinical microbiology, and clinical genetics is also discussed.

  4. The laboratory workforce shortage: a managerial perspective.

    PubMed

    Cortelyou-Ward, Kendall; Ramirez, Bernardo; Rotarius, Timothy

    2011-01-01

    Most clinical laboratories in the nation report severe difficulties in recruitment and retention of most types of personnel. Other important factors impacting this problem include work complexities, increased automation, and a graying workforce. As a further challenge, institutional needs for clinical laboratory personnel are expected to grow significantly in the next decade. This article examines the current situation of the clinical laboratory workforce. It analyzes the different types of personnel; the managerial, supervision, and line positions that are key for different types of laboratories; the job outlook and recent projections for different types of staff; and the current issues, trends, and challenges of the laboratory workforce. Laboratory managers need to take action with strategies suggested for overcoming these challenges. Most importantly, they need to become transformational leaders by developing effective staffing models, fostering healthy and productive work environments, and creating value with a strategic management culture and implementation of knowledge management.

  5. Compliance of clinical microbiology laboratories in the United States with current recommendations for processing respiratory tract specimens from patients with cystic fibrosis.

    PubMed

    Zhou, Juyan; Garber, Elizabeth; Desai, Manisha; Saiman, Lisa

    2006-04-01

    Respiratory tract specimens from patients with cystic fibrosis (CF) require unique processing by clinical microbiology laboratories to ensure detection of all potential pathogens. The present study sought to determine the compliance of microbiology laboratories in the United States with recently published recommendations for CF respiratory specimens. Microbiology laboratory protocols from 150 of 190 (79%) CF care sites were reviewed. Most described the use of selective media for Burkholderia cepacia complex (99%), Staphylococcus aureus (82%), and Haemophilus influenzae (89%) and identified the species of all gram-negative bacilli (87%). Only 52% delineated the use of agar diffusion assays for susceptibility testing of Pseudomonas aeruginosa. Standardizing laboratory practices will improve treatment, infection control, and our understanding of the changing epidemiology of CF microbiology.

  6. A professional development model for medical laboratory scientists working in the microbiology laboratory.

    PubMed

    Amerson, Megan H; Pulido, Lila; Garza, Melinda N; Ali, Faheem A; Greenhill, Brandy; Einspahr, Christopher L; Yarsa, Joseph; Sood, Pramilla K; Hu, Peter C

    2012-01-01

    The University of Texas M.D. Anderson Cancer Center, Division of Pathology and Laboratory Medicine is committed to providing the best pathology and medicine through: state-of-the art techniques, progressive ground-breaking research, education and training for the clinical diagnosis and research of cancer and related diseases. After surveying the laboratory staff and other hospital professionals, the Department administrators and Human Resource generalists developed a professional development model for Microbiology to support laboratory skills, behavior, certification, and continual education within its staff. This model sets high standards for the laboratory professionals to allow the labs to work at their fullest potential; it provides organization to training technologists based on complete laboratory needs instead of training technologists in individual areas in which more training is required if the laboratory needs them to work in other areas. This model is a working example for all microbiology based laboratories who want to set high standards and want their staff to be acknowledged for demonstrated excellence and professional development in the laboratory. The PDM model is designed to focus on the needs of the laboratory as well as the laboratory professionals.

  7. National Laboratory Planning: Developing Sustainable Biocontainment Laboratories in Limited Resource Areas.

    PubMed

    Yeh, Kenneth B; Adams, Martin; Stamper, Paul D; Dasgupta, Debanjana; Hewson, Roger; Buck, Charles D; Richards, Allen L; Hay, John

    2016-01-01

    Strategic laboratory planning in limited resource areas is essential for addressing global health security issues. Establishing a national reference laboratory, especially one with BSL-3 or -4 biocontainment facilities, requires a heavy investment of resources, a multisectoral approach, and commitments from multiple stakeholders. We make the case for donor organizations and recipient partners to develop a comprehensive laboratory operations roadmap that addresses factors such as mission and roles, engaging national and political support, securing financial support, defining stakeholder involvement, fostering partnerships, and building trust. Successful development occurred with projects in African countries and in Azerbaijan, where strong leadership and a clear management framework have been key to success. A clearly identified and agreed management framework facilitate identifying the responsibility for developing laboratory capabilities and support services, including biosafety and biosecurity, quality assurance, equipment maintenance, supply chain establishment, staff certification and training, retention of human resources, and sustainable operating revenue. These capabilities and support services pose rate-limiting yet necessary challenges. Laboratory capabilities depend on mission and role, as determined by all stakeholders, and demonstrate the need for relevant metrics to monitor the success of the laboratory, including support for internal and external audits. Our analysis concludes that alternative frameworks for success exist for developing and implementing capabilities at regional and national levels in limited resource areas. Thus, achieving a balance for standardizing practices between local procedures and accepted international standards is a prerequisite for integrating new facilities into a country's existing public health infrastructure and into the overall international scientific community.

  8. National Laboratory Planning: Developing Sustainable Biocontainment Laboratories in Limited Resource Areas

    PubMed Central

    Adams, Martin; Stamper, Paul D.; Dasgupta, Debanjana; Hewson, Roger; Buck, Charles D.; Richards, Allen L.; Hay, John

    2016-01-01

    Strategic laboratory planning in limited resource areas is essential for addressing global health security issues. Establishing a national reference laboratory, especially one with BSL-3 or -4 biocontainment facilities, requires a heavy investment of resources, a multisectoral approach, and commitments from multiple stakeholders. We make the case for donor organizations and recipient partners to develop a comprehensive laboratory operations roadmap that addresses factors such as mission and roles, engaging national and political support, securing financial support, defining stakeholder involvement, fostering partnerships, and building trust. Successful development occurred with projects in African countries and in Azerbaijan, where strong leadership and a clear management framework have been key to success. A clearly identified and agreed management framework facilitate identifying the responsibility for developing laboratory capabilities and support services, including biosafety and biosecurity, quality assurance, equipment maintenance, supply chain establishment, staff certification and training, retention of human resources, and sustainable operating revenue. These capabilities and support services pose rate-limiting yet necessary challenges. Laboratory capabilities depend on mission and role, as determined by all stakeholders, and demonstrate the need for relevant metrics to monitor the success of the laboratory, including support for internal and external audits. Our analysis concludes that alternative frameworks for success exist for developing and implementing capabilities at regional and national levels in limited resource areas. Thus, achieving a balance for standardizing practices between local procedures and accepted international standards is a prerequisite for integrating new facilities into a country's existing public health infrastructure and into the overall international scientific community. PMID:27559843

  9. Mapping Maize Genes: A Series of Research-Based Laboratory Exercises

    ERIC Educational Resources Information Center

    Makarevitch, Irina; Kralich, Elizabeth

    2011-01-01

    Open-ended, inquiry-based multiweek laboratory exercises are the key elements to increasing students' understanding and retention of the major biological concepts. Including original research into undergraduate teaching laboratories has also been shown to motivate students and improve their learning. Here, we present a series of original…

  10. Guidelines for biosafety laboratory competency: CDC and the Association of Public Health Laboratories.

    PubMed

    Delany, Judy R; Pentella, Michael A; Rodriguez, Joyce A; Shah, Kajari V; Baxley, Karen P; Holmes, David E

    2011-04-15

    These guidelines for biosafety laboratory competency outline the essential skills, knowledge, and abilities required for working with biologic agents at the three highest biosafety levels (BSLs) (levels 2, 3, and 4). The competencies are tiered to a worker's experience at three levels: entry level, midlevel (experienced), and senior level (supervisory or managerial positions). These guidelines were developed on behalf of CDC and the Association of Public Health Laboratories (APHL) by an expert panel comprising 27 experts representing state and federal public health laboratories, private sector clinical and research laboratories, and academic centers. They were then reviewed by approximately 300 practitioners representing the relevant fields. The guidelines are intended for laboratorians working with hazardous biologic agents, obtained from either samples or specimens that are maintained and manipulated in clinical, environmental, public health, academic, and research laboratories.

  11. Public Key Infrastructure Study

    DTIC Science & Technology

    1994-04-01

    commerce. This Public Key Infrastructure (PKI) study focuses on the United States Federal Government operations, but also addresses national and global ... issues in order to facilitate the interoperation of protected electronic commerce among the various levels of government in the U.S., private citizens

  12. Satellite-to-ground quantum key distribution.

    PubMed

    Liao, Sheng-Kai; Cai, Wen-Qi; Liu, Wei-Yue; Zhang, Liang; Li, Yang; Ren, Ji-Gang; Yin, Juan; Shen, Qi; Cao, Yuan; Li, Zheng-Ping; Li, Feng-Zhi; Chen, Xia-Wei; Sun, Li-Hua; Jia, Jian-Jun; Wu, Jin-Cai; Jiang, Xiao-Jun; Wang, Jian-Feng; Huang, Yong-Mei; Wang, Qiang; Zhou, Yi-Lin; Deng, Lei; Xi, Tao; Ma, Lu; Hu, Tai; Zhang, Qiang; Chen, Yu-Ao; Liu, Nai-Le; Wang, Xiang-Bin; Zhu, Zhen-Cai; Lu, Chao-Yang; Shu, Rong; Peng, Cheng-Zhi; Wang, Jian-Yu; Pan, Jian-Wei

    2017-09-07

    Quantum key distribution (QKD) uses individual light quanta in quantum superposition states to guarantee unconditional communication security between distant parties. However, the distance over which QKD is achievable has been limited to a few hundred kilometres, owing to the channel loss that occurs when using optical fibres or terrestrial free space that exponentially reduces the photon transmission rate. Satellite-based QKD has the potential to help to establish a global-scale quantum network, owing to the negligible photon loss and decoherence experienced in empty space. Here we report the development and launch of a low-Earth-orbit satellite for implementing decoy-state QKD-a form of QKD that uses weak coherent pulses at high channel loss and is secure because photon-number-splitting eavesdropping can be detected. We achieve a kilohertz key rate from the satellite to the ground over a distance of up to 1,200 kilometres. This key rate is around 20 orders of magnitudes greater than that expected using an optical fibre of the same length. The establishment of a reliable and efficient space-to-ground link for quantum-state transmission paves the way to global-scale quantum networks.

  13. Feasibility of Key Star Wars Technology at Center of Debate over Information a Cal. Laboratory Gave Government.

    ERIC Educational Resources Information Center

    McDonald, Kim

    1988-01-01

    The question of whether a university is responsible for the technical accuracy of information released by senior administrators of a laboratory it is charged with overseeing is examined in the case involving a dispute at the Lawrence Livermore National Laboratory that is overseen by the University of California. (MLW)

  14. United States Air Force Summer Research Program -- 1993. Volume 13. Phillips Laboratory

    DTIC Science & Technology

    1993-12-01

    Research Kirtland Air Force Base, Albuquerque, NM August 1993 14-1 My Summer Apprenticeship At Kirtland Air Force Base, Phillips Laboratory Andrea Garcia...AFOSR Summer Research Program Phillips Laboratory Sponsored By: Air Force Office of Scientific Research Kirtland Air Force Base, Albuquerque, NM... Phillips Laboratory Sponsored by: Air

  15. United States Air Force Summer Research Program -- 1993. Volume 3. Phillips Laboratory

    DTIC Science & Technology

    1993-12-01

    PHILLIPS LABORATORY KIRTLAND AIR FORCE BASE, NEW MEXICO SPONSORED BY: AIR FORCE OFFICE OF SCIENTIFIC RESEARCH ROLLING AIR FORCE BASE, WASHINGTON ,D.C...Report for. Summer Faculty Research Program at Phillips Laboratory Kirtland Air Force Base Sponsored by: Air Force Offlce of Scientific Research ...Prcgram Phillips Laboratory Kirtland

  16. Present and future free-space quantum key distribution

    NASA Astrophysics Data System (ADS)

    Nordholt, Jane E.; Hughes, Richard J.; Morgan, George L.; Peterson, C. Glen; Wipf, Christopher C.

    2002-04-01

    Free-space quantum key distribution (QKD), more popularly know as quantum cryptography, uses single-photon free-space optical communications to distribute the secret keys required for secure communications. At Los Alamos National Laboratory we have demonstrated a fully automated system that is capable of operations at any time of day over a horizontal range of several kilometers. This has proven the technology is capable of operation from a spacecraft to the ground, opening up the possibility of QKD between any group of users anywhere on Earth. This system, the prototyping of a new system for use on a spacecraft, and the techniques required for world-wide quantum key distribution will be described. The operational parameters and performance of a system designed to operate between low earth orbit (LEO) and the ground will also be discussed.

  17. Oklahoma's Mobile Computer Graphics Laboratory.

    ERIC Educational Resources Information Center

    McClain, Gerald R.

    This Computer Graphics Laboratory houses an IBM 1130 computer, U.C.C. plotter, printer, card reader, two key punch machines, and seminar-type classroom furniture. A "General Drafting Graphics System" (GDGS) is used, based on repetitive use of basic coordinate and plot generating commands. The system is used by 12 institutions of higher education…

  18. Linking results of key and supplementary comparisons of AC/DC voltage transfer references

    NASA Astrophysics Data System (ADS)

    Velychko, Oleh

    2018-04-01

    A regional key comparison (KC) COOMET.EM-K6.a and a supplementary comparison (SC) COOMET.EM-S1 of AC/DC voltage transfer references were conducted between participating laboratories from the Eurasian region. Measurements were made over the period 2004-2014. The results showed good agreement between all but one of the participating laboratories. The proposed procedure of linking results of key and SCs of regional metrology organization of AC/DC voltage transfer references is presented. Linking results is realized for COOMET.EM-K6.a and CCEM-K6.a KCs, and for COOMET.EM-K6.a KC and COOMET.EM-S1 SC.

  19. LACIE analyst interpretation keys

    NASA Technical Reports Server (NTRS)

    Baron, J. G.; Payne, R. W.; Palmer, W. F. (Principal Investigator)

    1979-01-01

    Two interpretation aids, 'The Image Analysis Guide for Wheat/Small Grains Inventories' and 'The United States and Canadian Great Plains Regional Keys', were developed during LACIE phase 2 and implemented during phase 3 in order to provide analysts with a better understanding of the expected ranges in color variation of signatures for individual biostages and of the temporal sequences of LANDSAT signatures. The keys were tested using operational LACIE data, and the results demonstrate that their use provides improved labeling accuracy in all analyst experience groupings, in all geographic areas within the U.S. Great Plains, and during all periods of crop development.

  20. Anomaly Monitoring Method for Key Components of Satellite

    PubMed Central

    Fan, Linjun; Xiao, Weidong; Tang, Jun

    2014-01-01

    This paper presented a fault diagnosis method for key components of satellite, called Anomaly Monitoring Method (AMM), which is made up of state estimation based on Multivariate State Estimation Techniques (MSET) and anomaly detection based on Sequential Probability Ratio Test (SPRT). On the basis of analysis failure of lithium-ion batteries (LIBs), we divided the failure of LIBs into internal failure, external failure, and thermal runaway and selected electrolyte resistance (R e) and the charge transfer resistance (R ct) as the key parameters of state estimation. Then, through the actual in-orbit telemetry data of the key parameters of LIBs, we obtained the actual residual value (R X) and healthy residual value (R L) of LIBs based on the state estimation of MSET, and then, through the residual values (R X and R L) of LIBs, we detected the anomaly states based on the anomaly detection of SPRT. Lastly, we conducted an example of AMM for LIBs, and, according to the results of AMM, we validated the feasibility and effectiveness of AMM by comparing it with the results of threshold detective method (TDM). PMID:24587703

  1. Biased three-intensity decoy-state scheme on the measurement-device-independent quantum key distribution using heralded single-photon sources.

    PubMed

    Zhang, Chun-Hui; Zhang, Chun-Mei; Guo, Guang-Can; Wang, Qin

    2018-02-19

    At present, most of the measurement-device-independent quantum key distributions (MDI-QKD) are based on weak coherent sources and limited in the transmission distance under realistic experimental conditions, e.g., considering the finite-size-key effects. Hence in this paper, we propose a new biased decoy-state scheme using heralded single-photon sources for the three-intensity MDI-QKD, where we prepare the decoy pulses only in X basis and adopt both the collective constraints and joint parameter estimation techniques. Compared with former schemes with WCS or HSPS, after implementing full parameter optimizations, our scheme gives distinct reduced quantum bit error rate in the X basis and thus show excellent performance, especially when the data size is relatively small.

  2. ISO 15189 accreditation: Requirements for quality and competence of medical laboratories, experience of a laboratory I.

    PubMed

    Guzel, Omer; Guner, Ebru Ilhan

    2009-03-01

    Medical laboratories are the key partners in patient safety. Laboratory results influence 70% of medical diagnoses. Quality of laboratory service is the major factor which directly affects the quality of health care. The clinical laboratory as a whole has to provide the best patient care promoting excellence. International Standard ISO 15189, based upon ISO 17025 and ISO 9001 standards, provides requirements for competence and quality of medical laboratories. Accredited medical laboratories enhance credibility and competency of their testing services. Our group of laboratories, one of the leading institutions in the area, had previous experience with ISO 9001 and ISO 17025 Accreditation at non-medical sections. We started to prepared for ISO 15189 Accreditation at the beginning of 2006 and were certified in March, 2007. We spent more than a year to prepare for accreditation. Accreditation scopes of our laboratory were as follows: clinical chemistry, hematology, immunology, allergology, microbiology, parasitology, molecular biology of infection serology and transfusion medicine. The total number of accredited tests is 531. We participate in five different PT programs. Inter Laboratory Comparison (ILC) protocols are performed with reputable laboratories. 82 different PT Program modules, 277 cycles per year for 451 tests and 72 ILC program organizations for remaining tests have been performed. Our laboratory also organizes a PT program for flow cytometry. 22 laboratories participate in this program, 2 cycles per year. Our laboratory has had its own custom made WEB based LIS system since 2001. We serve more than 500 customers on a real time basis. Our quality management system is also documented and processed electronically, Document Management System (DMS), via our intranet. Preparatory phase for accreditation, data management, external quality control programs, personnel related issues before, during and after accreditation process are presented. Every laboratory has

  3. How to implement decoy-state quantum key distribution for a satellite uplink with 50-dB channel loss

    NASA Astrophysics Data System (ADS)

    Meyer-Scott, Evan; Yan, Zhizhong; MacDonald, Allison; Bourgoin, Jean-Philippe; Hübel, Hannes; Jennewein, Thomas

    2011-12-01

    Quantum key distribution (QKD) takes advantage of fundamental properties of quantum physics to allow two distant parties to share a secret key; however, QKD is hampered by a distance limitation of a few hundred kilometers on Earth. The most immediate solution for global coverage is to use a satellite, which can receive separate QKD transmissions from two or more ground stations and act as a trusted node to link these ground stations. In this article we report on a system capable of performing QKD in the high loss regime expected in an uplink to a satellite using weak coherent pulses and decoy states. Such a scenario profits from the simplicity of its receiver payload, but has so far been considered to be infeasible due to very high transmission losses (40-50 dB). The high loss is overcome by implementing an innovative photon source and advanced timing analysis. Our system handles up to 57 dB photon loss in the infinite key limit, confirming the viability of the satellite uplink scenario. We emphasize that while this system was designed with a satellite uplink in mind, it could just as easily overcome high losses on any free space QKD link.

  4. Quantum key distribution without the wavefunction

    NASA Astrophysics Data System (ADS)

    Niestegge, Gerd

    A well-known feature of quantum mechanics is the secure exchange of secret bit strings which can then be used as keys to encrypt messages transmitted over any classical communication channel. It is demonstrated that this quantum key distribution allows a much more general and abstract access than commonly thought. The results include some generalizations of the Hilbert space version of quantum key distribution, but are based upon a general nonclassical extension of conditional probability. A special state-independent conditional probability is identified as origin of the superior security of quantum key distribution; this is a purely algebraic property of the quantum logic and represents the transition probability between the outcomes of two consecutive quantum measurements.

  5. 2011 Mars Science Laboratory Mission Design Overview

    NASA Technical Reports Server (NTRS)

    Abilleira, Fernando

    2010-01-01

    Scheduled to launch in the fall of 2011 with arrival at Mars occurring in the summer of 2012, NASA's Mars Science Laboratory will explore and assess whether Mars ever had conditions capable of supporting microbial life. In order to achieve its science objectives, the Mars Science Laboratory will be equipped with the most advanced suite of instruments ever sent to the surface of the Red Planet. Delivering the next mobile science laboratory safely to the surface of Mars has various key challenges derived from a strict set of requirements which include launch vehicle performance, spacecraft mass, communications coverage during Entry, Descent, and Landing, atmosphere-relative entry speeds, latitude accessibility, and dust storm season avoidance among others. The Mars Science Laboratory launch/arrival strategy selected after careful review satisfies all these mission requirements.

  6. Assessment of laboratory logistics management information system practice for HIV/AIDS and tuberculosis laboratory commodities in selected public health facilities in Addis Ababa, Ethiopia.

    PubMed

    Desale, Adino; Taye, Bineyam; Belay, Getachew; Nigatu, Alemayehu

    2013-01-01

    Logistics management information system for health commodities remained poorly implemented in most of developing countries. To assess the status of laboratory logistics management information system for HIV/AIDS and tuberculosis laboratory commodities in public health facilities in Addis Ababa. A cross-sectional descriptive study was conducted from September 2010-January 2011 at selected public health facilities. A stratified random sampling method was used to include a total of 43 facilities which, were investigated through quantitative methods using structured questionnaires interviews. Focus group discussion with the designated supply chain managers and key informant interviews were conducted for the qualitative method. There exists a well-designed logistics system for laboratory commodities with trained pharmacy personnel, distributed standard LMIS formats and established inventory control procedures. However, majority of laboratory professionals were not trained in LMIS. Majority of the facilities (60.5%) were stocked out for at least one ART monitoring and TB laboratory reagents and the highest stock out rate was for chemistry reagents. Expired ART monitoring laboratory commodities were found in 25 (73.5%) of facilities. Fifty percent (50%) of the assessed hospitals and 54% of health centers were currently using stock/bin cards for all HIV/AIDS and TB laboratory commodities in main pharmacy store, among these only 25% and 20.8% of them were updated with accurate information matching with the physical count done at the time of visit for hospitals and health centers respectively. Even though there exists a well designed laboratory LMIS, keeping quality stock/bin cards and LMIS reports were very low. Key ART monitoring laboratory commodities were stock out at many facilities at the day of visit and during the past six months. Based on findings, training of laboratory personnel's managing laboratory commodities and keeping accurate inventory control procedures

  7. Assessment of laboratory logistics management information system practice for HIV/AIDS and tuberculosis laboratory commodities in selected public health facilities in Addis Ababa, Ethiopia

    PubMed Central

    Desale, Adino; Taye, Bineyam; Belay, Getachew; Nigatu, Alemayehu

    2013-01-01

    Introduction Logistics management information system for health commodities remained poorly implemented in most of developing countries. To assess the status of laboratory logistics management information system for HIV/AIDS and tuberculosis laboratory commodities in public health facilities in Addis Ababa. Methods A cross-sectional descriptive study was conducted from September 2010-January 2011 at selected public health facilities. A stratified random sampling method was used to include a total of 43 facilities which, were investigated through quantitative methods using structured questionnaires interviews. Focus group discussion with the designated supply chain managers and key informant interviews were conducted for the qualitative method. Results There exists a well-designed logistics system for laboratory commodities with trained pharmacy personnel, distributed standard LMIS formats and established inventory control procedures. However, majority of laboratory professionals were not trained in LMIS. Majority of the facilities (60.5%) were stocked out for at least one ART monitoring and TB laboratory reagents and the highest stock out rate was for chemistry reagents. Expired ART monitoring laboratory commodities were found in 25 (73.5%) of facilities. Fifty percent (50%) of the assessed hospitals and 54% of health centers were currently using stock/bin cards for all HIV/AIDS and TB laboratory commodities in main pharmacy store, among these only 25% and 20.8% of them were updated with accurate information matching with the physical count done at the time of visit for hospitals and health centers respectively. Conclusion Even though there exists a well designed laboratory LMIS, keeping quality stock/bin cards and LMIS reports were very low. Key ART monitoring laboratory commodities were stock out at many facilities at the day of visit and during the past six months. Based on findings, training of laboratory personnel's managing laboratory commodities and keeping

  8. Laboratory measurements of trace gas emissions from biomass burning of fuel types from the southeastern and southwestern United States

    Treesearch

    I. R. Burling; R. J. Yokelson; D. W. T. Griffith; T. J. Johnson; P. Veres; J. M. Roberts; C. Warneke; S. P. Urbanski; J. Reardon; D. R. Weise; W. M. Hao; J. de Gouw

    2010-01-01

    Vegetation commonly managed by prescribed burning was collected from five southeastern and southwestern US military bases and burned under controlled conditions at the US Forest Service Fire Sciences Laboratory in Missoula, Montana. The smoke emissions were measured with a large suite of state-of-the-art instrumentation including an open-path Fourier transform infrared...

  9. Effects of Enhanced Laboratory Instructional Technique on Senior Secondary Students' Attitude toward Chemistry in Oyo Township, Oyo State, Nigeria

    ERIC Educational Resources Information Center

    Adesoji, Francis Adewumi; Raimi, Sikiru Morakinyo

    2004-01-01

    The study examined the effect of supplementing laboratory instruction with problem solving strategy and or practical skills teaching on students' attitude toward chemistry. A total of 286 senior secondary class II students (145 males and 141 females) drawn from four local government areas in Oyo township in Oyo state, Nigeria, took part in the…

  10. "Key to Freshwater Algae": A Web-Based Tool to Enhance Understanding of Microscopic Biodiversity

    ERIC Educational Resources Information Center

    Shayler, Hannah A.; Siver, Peter A.

    2006-01-01

    The Freshwater Ecology Laboratory at Connecticut College has developed an interactive, Web-based identification key to freshwater algal genera using the Lucid Professional and Lucid 3 software developed by the Centre for Biological Information Technology at the University of Queensland, Brisbane, Australia. The "Key to Freshwater Algae"…

  11. An Undergraduate Laboratory Experiment in Bioinorganic Chemistry: Ligation States of Myoglobin

    ERIC Educational Resources Information Center

    Bailey, James A.

    2011-01-01

    Although there are numerous inorganic model systems that are readily presented as undergraduate laboratory experiments in bioinorganic chemistry, there are few examples that explore the inorganic chemistry of actual biological molecules. We present a laboratory experiment using the oxygen-binding protein myoglobin that can be easily incorporated…

  12. NASA's Propulsion Research Laboratory

    NASA Technical Reports Server (NTRS)

    2004-01-01

    The grand opening of NASA's new, world-class laboratory for research into future space transportation technologies located at the Marshall Space Flight Center (MSFC) in Huntsville, Alabama, took place in July 2004. The state-of-the-art Propulsion Research Laboratory (PRL) serves as a leading national resource for advanced space propulsion research. Its purpose is to conduct research that will lead to the creation and development of innovative propulsion technologies for space exploration. The facility is the epicenter of the effort to move the U.S. space program beyond the confines of conventional chemical propulsion into an era of greatly improved access to space and rapid transit throughout the solar system. The laboratory is designed to accommodate researchers from across the United States, including scientists and engineers from NASA, the Department of Defense, the Department of Energy, universities, and industry. The facility, with 66,000 square feet of useable laboratory space, features a high degree of experimental capability. Its flexibility allows it to address a broad range of propulsion technologies and concepts, such as plasma, electromagnetic, thermodynamic, and propellant propulsion. An important area of emphasis is the development and utilization of advanced energy sources, including highly energetic chemical reactions, solar energy, and processes based on fission, fusion, and antimatter. The Propulsion Research Laboratory is vital for developing the advanced propulsion technologies needed to open up the space frontier, and sets the stage of research that could revolutionize space transportation for a broad range of applications.

  13. Decoy-state quantum key distribution with a leaky source

    NASA Astrophysics Data System (ADS)

    Tamaki, Kiyoshi; Curty, Marcos; Lucamarini, Marco

    2016-06-01

    In recent years, there has been a great effort to prove the security of quantum key distribution (QKD) with a minimum number of assumptions. Besides its intrinsic theoretical interest, this would allow for larger tolerance against device imperfections in the actual implementations. However, even in this device-independent scenario, one assumption seems unavoidable, that is, the presence of a protected space devoid of any unwanted information leakage in which the legitimate parties can privately generate, process and store their classical data. In this paper we relax this unrealistic and hardly feasible assumption and introduce a general formalism to tackle the information leakage problem in most of existing QKD systems. More specifically, we prove the security of optical QKD systems using phase and intensity modulators in their transmitters, which leak the setting information in an arbitrary manner. We apply our security proof to cases of practical interest and show key rates similar to those obtained in a perfectly shielded environment. Our work constitutes a fundamental step forward in guaranteeing implementation security of quantum communication systems.

  14. Quantum key distribution using basis encoding of Gaussian-modulated coherent states

    NASA Astrophysics Data System (ADS)

    Huang, Peng; Huang, Jingzheng; Zhang, Zheshen; Zeng, Guihua

    2018-04-01

    The continuous-variable quantum key distribution (CVQKD) has been demonstrated to be available in practical secure quantum cryptography. However, its performance is restricted strongly by the channel excess noise and the reconciliation efficiency. In this paper, we present a quantum key distribution (QKD) protocol by encoding the secret keys on the random choices of two measurement bases: the conjugate quadratures X and P . The employed encoding method can dramatically weaken the effects of channel excess noise and reconciliation efficiency on the performance of the QKD protocol. Subsequently, the proposed scheme exhibits the capability to tolerate much higher excess noise and enables us to reach a much longer secure transmission distance even at lower reconciliation efficiency. The proposal can work alternatively to strengthen significantly the performance of the known Gaussian-modulated CVQKD protocol and serve as a multiplier for practical secure quantum cryptography with continuous variables.

  15. 42 CFR 493.551 - General requirements for laboratories.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false General requirements for laboratories. 493.551... SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Accreditation by a Private, Nonprofit Accreditation Organization or Exemption Under an Approved State Laboratory Program § 493.551...

  16. 42 CFR 493.551 - General requirements for laboratories.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false General requirements for laboratories. 493.551... SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Accreditation by a Private, Nonprofit Accreditation Organization or Exemption Under an Approved State Laboratory Program § 493.551...

  17. Laboratory-based surveillance of paratyphoid fever in the United States: travel and antimicrobial resistance.

    PubMed

    Gupta, Sundeep K; Medalla, Felicita; Omondi, Michael W; Whichard, Jean M; Fields, Patricia I; Gerner-Smidt, Peter; Patel, Nehal J; Cooper, Kara L F; Chiller, Tom M; Mintz, Eric D

    2008-06-01

    The incidence of paratyphoid fever, including paratyphoid fever caused by antimicrobial-resistant strains, is increasing globally. However, the epidemiologic and laboratory characteristics of paratyphoid fever in the United States have never been studied. We attempted to interview all patients who had been infected with laboratory-confirmed Salmonella serotypes Paratyphi A, Paratyphi B, or Paratyphi C in the United States with specimens collected from 1 April 2005 through 31 March 2006. At the Centers for Disease Control and Prevention (CDC), isolates underwent serotype confirmation, antimicrobial susceptibility testing, and pulsed-field gel electrophoresis typing. Of 149 patients infected with Salmonella Paratyphi A, we obtained epidemiologic information for 89 (60%); 55 (62%) of 86 were hospitalized. Eighty-five patients (96%) reported having travel internationally, and 80 (90%) had traveled to South Asia. Of the 146 isolates received at the CDC, 127 (87%) were nalidixic acid resistant; nalidixic acid resistance was associated with travel to South Asia (odds ratio, 17.0; 95% confidence interval, 3.8-75.9). All nalidixic acid-resistant isolates showed decreased susceptibility to ciprofloxacin (minimum inhibitory concentration, > or = 0.12 microg/mL). Of 49 patients infected with Salmonella Paratyphi B, only 12 (24%) were confirmed to have Paratyphi B when tested at the CDC. Four (67%) of 6 patients were hospitalized, and 5 (83%) reported travel (4 to the Andean region of South America). One case of Salmonella Paratyphi C infection was reported in a traveler to West Africa with a urinary tract infection. Physicians should be aware of the increasing incidence of infection due to Salmonella Paratyphi A and treatment options given its widespread antimicrobial resistance. A paratyphoid fever vaccine is urgently needed. Continued surveillance for paratyphoid fever will help guide future prevention and treatment recommendations.

  18. Extended analysis of the Trojan-horse attack in quantum key distribution

    NASA Astrophysics Data System (ADS)

    Vinay, Scott E.; Kok, Pieter

    2018-04-01

    The discrete-variable quantum key distribution protocols based on the 1984 protocol of Bennett and Brassard (BB84) are known to be secure against an eavesdropper, Eve, intercepting the flying qubits and performing any quantum operation on them. However, these protocols may still be vulnerable to side-channel attacks. We investigate the Trojan-horse side-channel attack where Eve sends her own state into Alice's apparatus and measures the reflected state to estimate the key. We prove that the separable coherent state is optimal for Eve among the class of multimode Gaussian attack states, even in the presence of thermal noise. We then provide a bound on the secret key rate in the case where Eve may use any separable state.

  19. Anatomy of a value proposition for laboratory medicine.

    PubMed

    Price, Christopher P; St John, Andrew

    2014-09-25

    Value is now becoming a key driver in the ongoing development of healthcare delivery; key facets include the identification of what is valuable and how that value can be identified, leveraged, and delivered. The concept of a value proposition is widely used in business but can be used in healthcare as a statement of the benefits, costs and value that an organization can deliver to its customers. The foundation of this statement in laboratory medicine is evidence of clinical and cost effectiveness, not only for the patient, but also for other stakeholders involved in the delivery of healthcare, e.g., the carer, service provider, commissioner, purchaser, and the supplier of the test or device, as well as society as a whole. However the value of any laboratory medicine investigation is only achieved if the output (the test result(s)), is acted upon by the initiator of the investigation. Laboratory medicine is one part of a complex intervention, and so the value proposition should encompass the breadth of that intervention - from addressing the unmet need through the generation of clinical, operational and economic outcomes. A value proposition in laboratory medicine is central to successful innovation and quality improvement in healthcare. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Quantum Key Distribution

    NASA Astrophysics Data System (ADS)

    Hughes, Richard

    2004-05-01

    Quantum key distribution (QKD) uses single-photon communications to generate the shared, secret random number sequences that are used to encrypt and decrypt secret communications. The unconditional security of QKD is based on the interplay between fundamental principles of quantum physics and information theory. An adversary can neither successfully tap the transmissions, nor evade detection (eavesdropping raises the key error rate above a threshold value). QKD could be particularly attractive for free-space optical communications, both ground-based and for satellites. I will describe a QKD experiment performed over multi-kilometer line-of-sight paths, which serves as a model for a satellite-to-ground key distribution system. The system uses single-photon polarization states, without active polarization switching, and for the first time implements the complete BB84 QKD protocol including, reconciliation, privacy amplification and the all-important authentication stage. It is capable of continuous operation throughout the day and night, achieving the self-sustaining production of error-free, shared, secret bits. I will also report on the results of satellite-to-ground QKD modeling.

  1. Laboratory evidence for a key intermediate in the Venus atmosphere: Peroxychloroformyl radical

    PubMed Central

    Pernice, Holger; Garcia, Placido; Willner, Helge; Francisco, Joseph S.; Mills, Franklin P.; Allen, Mark; Yung, Yuk L.

    2004-01-01

    For two decades, the peroxychloroformyl radical, ClC(O)OO, has played a central role in models of the chemical stability of the Venus atmosphere. No confirmation, however, has been possible in the absence of laboratory measurements for ClC(O)OO. We report the isolation of ClC(O)OO in a cryogenic matrix and its infrared and ultraviolet spectral signatures. These experiments show that ClC(O)OO is thermally and photolytically stable in the Venus atmosphere. These experimental discoveries validate the existence of ClC(O)OO, confirm several longstanding model assumptions, and provide a basis for the astronomical search for this important radical species. PMID:15375212

  2. Laboratory Evidence for a Key Intermediate in the Venus Atmosphere: Peroxychloroformyl Radical

    NASA Technical Reports Server (NTRS)

    Pernice, Holger; Garcia, Placido; Willner, Helge; Francisco, Joseph S.; Mills, Franklin P.; Allen, Mark; Yung, Yuk L.

    2004-01-01

    For two decades, the peroxychloroformyl radical, ClC(O)OO, has played a central role in models of the chemical stability of the Venus atmosphere. No confirmation, however, has been possible in the absence of laboratory measurements for ClC(O)OO. We report the isolation of ClC(O)OO in a cryogenic matrix and its infrared and ultraviolet spectral signatures. These experiments show that ClC(O)OO is thermally and photolytically stable in the Venus atmosphere. These experimental discoveries validate the existence of ClC(O)OO, confirm several longstanding model assumptions, and provide a basis for the astronomical search for this important radical species.

  3. Quality of Liver and Kidney Function Tests among Public Medical Laboratories in Western Region of Amhara National Regional State of Ethiopia.

    PubMed

    Teka, Abaynesh; Kibatu, Girma

    2012-03-01

    Medical laboratories play essential roles in measurements of substances in body fluids for the purpose of diagnosis, treatment, prevention, and for greater understanding of the disease process. Thus, data generated from have to be reliable for which strict quality control, management and assurance are maintained. The aim of this study is to assess the accuracy and precision of clinical chemistry laboratories in western region of Amhara national regional state of Ethiopia in testing liver and kidney functions. Eight laboratories in hospitals and a Regional Health Research Laboratory Center participated in this study from February to March, 2011. Each participant was requested to measure six specimens for six chemistry tests from two control samples. Three hundred twenty four test results to be reported from all participant laboratories, if all measurements can be made, were designed to be collected and statistically evaluated. None of the study subject laboratories could deliver all the six tests for estimation of both liver and renal functions simultaneously during the study period. Only 213 values from the expected 324 values were reported and about 65 % of the 213 values reported fell outside of the allowable limits of errors for the chemistry tests of the control specimen used. This study finding showed that there were lack of accuracy and precision in chemistry measurements. A regular survey on medical laboratories should be conducted questioning the accuracy and precision of their analyses in order to sustain improvements in the quality of services provided by participating laboratories for the benefit of patients. Laboratory Quality Management Systems appreciate the need for regular quality control and quality assessment schemes in medical laboratories.

  4. United States Air Force Summer Research Program -- 1991. High School Apprenticeship Program (HSAP) Reports, Volume 12: Rome Laboratory, Arnold Engineering Development Plan

    DTIC Science & Technology

    1991-12-01

    UNITED STATES AIR FORCE SUMMER RESEARCH PROGRAM -- 19k’ HIGH SCF-0)OL APPRENTICESHIP PROGRAM (HSAP) REtFOC2TS VOLUME 12 ROME LABORATORY ARNOLD...capacity requirements. In the United States and Japan, it has 1.544 Mbps channels (23B+D), and Europe has 2.048 Mbps channels (30B+D). Both are provided over...because of the standard 64 kbps and the layered protocols. Even though the United States and Europe have different primary access channels, the basic

  5. Extending key sharing: how to generate a key tightly coupled to a network security policy

    NASA Astrophysics Data System (ADS)

    Kazantzidis, Matheos

    2006-04-01

    Current state of the art security policy technologies, besides the small scale limitation and largely manual nature of accompanied management methods, are lacking a) in real-timeliness of policy implementation and b) vulnerabilities and inflexibility stemming from the centralized policy decision making; even if, for example, a policy description or access control database is distributed, the actual decision is often a centralized action and forms a system single point of failure. In this paper we are presenting a new fundamental concept that allows implement a security policy by a systematic and efficient key distribution procedure. Specifically, we extend the polynomial Shamir key splitting. According to this, a global key is split into n parts, any k of which can re-construct the original key. In this paper we present a method that instead of having "any k parts" be able to re-construct the original key, the latter can only be reconstructed if keys are combined as any access control policy describes. This leads into an easily deployable key generation procedure that results a single key per entity that "knows" its role in the specific access control policy from which it was derived. The system is considered efficient as it may be used to avoid expensive PKI operations or pairwise key distributions as well as provides superior security due to its distributed nature, the fact that the key is tightly coupled to the policy, and that policy change may be implemented easier and faster.

  6. Electric-field assisted spin torque nano-oscillator and binary frequency shift keying modulation

    NASA Astrophysics Data System (ADS)

    Zhang, Xiangli; Chen, Hao-Hsuan; Zhang, Zongzhi; Liu, Yaowen

    2018-04-01

    Electric-controlled magnetization precession introduces technologically relevant possibility for developing spin torque nano-oscillators (STNO) with potential applications in microwave emission. Using the perpendicularly magnetized magnetic tunnel junction (MTJ), we show that the magnetization oscillation frequency can be tuned by the co-action of electric field and spin polarized current. The dynamical phase diagram of MTJ-based STNO is analytically predicted through coordinate transformation from the laboratory frame to the rotation frame, by which the nonstationary out-of-plane magnetization precession process is therefore transformed into the stationary process in the rotation frame. Furthermore, using this STNO as a microwave source, we numerically demonstrate that the bit signal can be transmitted by a binary frequency shift keying (BFSK) modulation technique. The BFSK scheme shows good modulation features with no transient state.

  7. Setting objectives for managing Key deer

    USGS Publications Warehouse

    Diefenbach, Duane R.; Wagner, Tyler; Stauffer, Glenn E.

    2014-01-01

    The U.S. Fish and Wildlife Service (FWS) is responsible for the protection and management of Key deer (Odocoileus virginianus clavium) because the species is listed as Endangered under the Endangered Species Act (ESA). The purpose of the ESA is to protect and recover imperiled species and the ecosystems upon which they depend. There are a host of actions that could possibly be undertaken to recover the Key deer population, but without a clearly defined problem and stated objectives it can be difficult to compare and evaluate alternative actions. In addition, management goals and the acceptability of alternative management actions are inherently linked to stakeholders, who should be engaged throughout the process of developing a decision framework. The purpose of this project was to engage a representative group of stakeholders to develop a problem statement that captured the management problem the FWS must address with Key deer and identify objectives that, if met, would help solve the problem. In addition, the objectives were organized in a hierarchical manner (i.e., an objectives network) to show how they are linked, and measurable attributes were identified for each objective. We organized a group of people who represented stakeholders interested in and potentially affected by the management of Key deer. These stakeholders included individuals who represented local, state, and federal governments, non-governmental organizations, the general public, and local businesses. This stakeholder group met five full days over the course of an eight-week period to identify objectives that would address the following problem:“As recovery and removal from the Endangered Species list is the purpose of the Endangered Species Act, the U.S. Fish and Wildlife Service needs a management approach that will ensure a sustainable, viable, and healthy Key deer population. Urbanization has affected the behavior and population dynamics of the Key deer and the amount and characteristics

  8. An Identification Key to Rodent Prey in Owl Pellets from the Northwestern and Southeastern United States: Employing Incisor Size to Distinguish among Genera

    ERIC Educational Resources Information Center

    Hager, Stephen B.; Cosentino, Bradley J.

    2006-01-01

    We present an identification key to the common rodent prey found in owl pellets from the Northwestern (NW) and Southeastern (SE) United States that is based on differences in incisor size (arc diameter) among genera.

  9. Ethics in the laboratory examination of patients

    PubMed Central

    Nyrhinen, T.; Leino-Kilpi, H.

    2000-01-01

    Various value problems are connected with the clinical examination of patients. The purpose of this literature review is to clarify: 1) in which patient examinations ethical problems are generally found; 2) what kind of ethical problems are found in the different phases of the examination process, and 3) what kind of ethical problems are found in connection with the use of examination results. Genetic testing, autopsy, prenatal and HIV examinations were ethically the most problematic laboratory examinations. The most problematic phase in the laboratory examination process proved to be the pre-analytic phase. At present the results of laboratory examination are used more and more often for the prediction of diseases. The problems appear when the examination results are used for discrimination and stigmatisation. Because of the lack of empirical ethical research, it is important to chart empirical knowledge about present value conflict situations involved in the laboratory examination process. Key Words: Ethic • laboratory • test • examination • diagnosis • patient PMID:10701173

  10. Undergraduate Student Satisfaction and Achievement at the GetWET Observatory: A Fluid Learning Experience at Colorado State University

    ERIC Educational Resources Information Center

    Rathburn, Sara L.; Weinberg, Andrea E.

    2011-01-01

    The GetWET Observatory was developed as part of an overall course redesign of the Introductory Geology Laboratory at Colorado State University to improve student learning of key surface and groundwater concepts for nonmajors in science, technology, engineering, and mathematics. Consisting of six groundwater monitoring wells, the GetWET Observatory…

  11. Selecting automation for the clinical chemistry laboratory.

    PubMed

    Melanson, Stacy E F; Lindeman, Neal I; Jarolim, Petr

    2007-07-01

    Laboratory automation proposes to improve the quality and efficiency of laboratory operations, and may provide a solution to the quality demands and staff shortages faced by today's clinical laboratories. Several vendors offer automation systems in the United States, with both subtle and obvious differences. Arriving at a decision to automate, and the ensuing evaluation of available products, can be time-consuming and challenging. Although considerable discussion concerning the decision to automate has been published, relatively little attention has been paid to the process of evaluating and selecting automation systems. To outline a process for evaluating and selecting automation systems as a reference for laboratories contemplating laboratory automation. Our Clinical Chemistry Laboratory staff recently evaluated all major laboratory automation systems in the United States, with their respective chemistry and immunochemistry analyzers. Our experience is described and organized according to the selection process, the important considerations in clinical chemistry automation, decisions and implementation, and we give conclusions pertaining to this experience. Including the formation of a committee, workflow analysis, submitting a request for proposal, site visits, and making a final decision, the process of selecting chemistry automation took approximately 14 months. We outline important considerations in automation design, preanalytical processing, analyzer selection, postanalytical storage, and data management. Selecting clinical chemistry laboratory automation is a complex, time-consuming process. Laboratories considering laboratory automation may benefit from the concise overview and narrative and tabular suggestions provided.

  12. The Virtual Robotics Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kress, R.L.; Love, L.J.

    The growth of the Internet has provided a unique opportunity to expand research collaborations between industry, universities, and the national laboratories. The Virtual Robotics Laboratory (VRL) is an innovative program at Oak Ridge National Laboratory (ORNL) that is focusing on the issues related to collaborative research through controlled access of laboratory equipment using the World Wide Web. The VRL will provide different levels of access to selected ORNL laboratory secondary education programs. In the past, the ORNL Robotics and Process Systems Division has developed state-of-the-art robotic systems for the Army, NASA, Department of Energy, Department of Defense, as well asmore » many other clients. After proof of concept, many of these systems sit dormant in the laboratories. This is not out of completion of all possible research topics. but from completion of contracts and generation of new programs. In the past, a number of visiting professors have used this equipment for their own research. However, this requires that the professor, and possibly his/her students, spend extended periods at the laboratory facility. In addition, only a very exclusive group of faculty can gain access to the laboratory and hardware. The VRL is a tool that enables extended collaborative efforts without regard to geographic limitations.« less

  13. Crime Laboratory Proficiency Testing Research Program.

    ERIC Educational Resources Information Center

    Peterson, Joseph L.; And Others

    A three-year research effort was conducted to design a crime laboratory proficiency testing program encompassing the United States. The objectives were to: (1) determine the feasibility of preparation and distribution of different classes of physical evidence; (2) assess the accuracy of criminalistics laboratories in the processing of selected…

  14. Ground State Structures of Boron-Rich Rhodium Boride: An Ab Initio Study

    NASA Astrophysics Data System (ADS)

    Chu, Bin-Hua; Zhao, Yuan; Yan, Jin-Liang; Li, Da

    2018-01-01

    Not Available Supported by the Natural Science Foundation of Shandong Province under Grant Nos ZR2016AP02, ZR2016FM38 and ZR2016EMP01, the Innovation Project of Ludong University under Grant No LB2016013, the Open Project of State Key Laboratory of Superhard Materials of Jilin University under Grant No 201605, and the National Natural Science Foundation of China under Grant Nos 11704170 and 61705097.

  15. Analyses of rocks and minerals from the laboratory of the United States Geological Survey, 1880 to 1914

    USGS Publications Warehouse

    Clarke, Frank Wigglesworth

    1915-01-01

    The present Geological Survey of the United States was organized in 1879. In 1880, in connection with the Colorado work, a chemical laboratory was established at Denver in charge of W. F. Hillebrand, with whom were associated Antony Guyard and, later, L. G. Eakins. In 1882 W. H. Melville was placed in charge of a second laboratory at San Francisco, and in the autumn of 1883 the central laboratory was started in Washington, with myself as chief chemist. In November, 1885, Dr. Hillebrand was transferred to Washington; early in 1888 he was followed by Mr. Eakins, and the Denver laboratory was discontinued. In the spring of 1890 Dr. Melville also was transferred to Washington, and since then the geochemical work of the Survey has been concentrated at headquarters. The special laboratories of the water-resources and technologic branches of the Survey are not included in this statement and their work is not represented in this bulletin.Up to January 1, 1914, nearly 8,000 analyses have been made in the laboratory at Washington of rocks, minerals, ores, waters, sediments, coals, metals, and other substances with which geology has to do. Some-hundreds of analyses were also made in the laboratories at Denver and San Francisco. A fair amount of research work upon mineralogical and analytical problems has also been done. In *all of this work the following chemists have been employed: E. T. Allen, R. K. Bailey, Charles Catlett, T. M. Chatard, F. W. Clarke, L. G. Eakins, J. G. Fairchild, F. A. Gooch, Antony Guyard, W. B. Hicks, W. F. Hillebrand, W. F. Hunt, W. H. Melville, H. C. McNeil, Chase Palmer, R. B. Riggs, W. T. Schaller, E. A. Schneider, George Steiger, H. N. Stokes, E. C. Sullivan, William Valentine, R. C. Wells, W. C. Wheeler, and J. E. Whitfield. At present, January 1, 1914, eight of these chemists are employed in the Survey. Other officers of the Survey have been occupied more or less with chemical questions, but the men named in this list were connected directly

  16. International Space Station United States Laboratory Module Water Recovery Management Subsystem Verification from Flight 5A to Stage ULF2

    NASA Technical Reports Server (NTRS)

    Williams, David E.; Labuda, Laura

    2009-01-01

    The International Space Station (ISS) Environmental Control and Life Support (ECLS) system comprises of seven subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), Vacuum System (VS), Water Recovery and Management (WRM), and Waste Management (WM). This paper provides a summary of the nominal operation of the United States (U.S.) Laboratory Module WRM design and detailed element methodologies utilized during the Qualification phase of the U.S. Laboratory Module prior to launch and the Qualification of all of the modification kits added to it from Flight 5A up and including Stage ULF2.

  17. CCM key comparison CCM.D-K4 'Hydrometer'

    NASA Astrophysics Data System (ADS)

    Lorefice, S.; Becerra, L. O.; Lenard, E.; Lee, Y. J.; Lee, W. G.; Madec, T.; Meury, P. A.; Caceres, J.; Santos, C.; Vamossy, C.; Man, J.; Fen, K.; Toda, K.; Wright, J.; Bettin, H.; Toth, H.

    2016-01-01

    This report presents the comparison philosophy, methodology, analysis and the results of the designed CCM.D-K4 key comparison that covered the calibration of high resolution hydrometers for liquid and alcoholometers in the density range 600 kg/m3 to 2000 kg/m3 at the temperature of 20°C. The main purpose of this comparison was not only to evaluate the degree of equivalence in the calibration of high accuracy hydrometers between NMI participants, but also to link, were it is possible, the results of previous comparisons to Key Comparison Reference Values (KCRVs) of CCM.D-K4. Eleven NMI laboratories took part in the CCM.D-K4 divided in two groups (petals). With the CCM.D-K4 purpose, two similar sets consisting of three hydrometers for liquid density determinations and an alcoholometer were circulated to the NMI participants as a travelling standard in the time interval from January 2011 to April 2012. Twelve Key Comparison Reference Values (KCRVs) for each petal have been obtained at the density values related to the tested density marks of the transfer standards by the results of participants. The KCRVs and corresponding uncertainties were calculated by the weighted mean in the case of consistent results, otherwise the median was used. The degree of equivalence (DoE) with respect to the corresponding KCRV was determined for each participant and, in this particular comparison, the Weighted Least Squares (WLS) method was used to link the individual DoE of each participant by a continuous function. Significant drift of the transfer standards was not detected. This report also gives instructions on calculating pair-wise degrees of equivalence, with the addition of any information on correlations that may be necessary to estimate more accurately as well as the procedure for linking international comparisons to the CCM.D-K4. Finally an example of linkage to the CCM.D-K4 is given by dealing with the results of the bilateral comparison between INRiM and NMIA, which was

  18. Rationale for cost-effective laboratory medicine.

    PubMed Central

    Robinson, A

    1994-01-01

    There is virtually universal consensus that the health care system in the United States is too expensive and that costs need to be limited. Similar to health care costs in general, clinical laboratory expenditures have increased rapidly as a result of increased utilization and inflationary trends within the national economy. Economic constraints require that a compromise be reached between individual welfare and limited societal resources. Public pressure and changing health care needs have precipitated both subtle and radical laboratory changes to more effectively use allocated resources. Responsibility for excessive laboratory use can be assigned primarily to the following four groups: practicing physicians, physicians in training, patients, and the clinical laboratory. The strategies to contain escalating health care costs have ranged from individualized physician education programs to government intervention. Laboratories have responded to the fiscal restraints imposed by prospective payment systems by attempting to reduce operational costs without adversely impacting quality. Although cost containment directed at misutilization and overutilization of existing services has conserved resources, to date, an effective cost control mechanism has yet to be identified and successfully implemented on a grand enough scale to significantly impact health care expenditures in the United States. PMID:8055467

  19. Clinical and laboratory variability in a cohort of patients diagnosed with type 1 VWD in the United States

    PubMed Central

    Christopherson, Pamela A.; Gill, Joan Cox; Friedman, Kenneth D.; Haberichter, Sandra L.; Bellissimo, Daniel B.; Udani, Rupa A.; Dasgupta, Mahua; Hoffmann, Raymond G.; Ragni, Margaret V.; Shapiro, Amy D.; Lusher, Jeanne M.; Lentz, Steven R.; Abshire, Thomas C.; Leissinger, Cindy; Hoots, W. Keith; Manco-Johnson, Marilyn J.; Gruppo, Ralph A.; Boggio, Lisa N.; Montgomery, Kate T.; Goodeve, Anne C.; James, Paula D.; Lillicrap, David; Peake, Ian R.; Montgomery, Robert R.

    2016-01-01

    von Willebrand disease (VWD) is the most common inherited bleeding disorder, and type 1 VWD is the most common VWD variant. Despite its frequency, diagnosis of type 1 VWD remains the subject of debate. In order to study the spectrum of type 1 VWD in the United States, the Zimmerman Program enrolled 482 subjects with a previous diagnosis of type 1 VWD without stringent laboratory diagnostic criteria. von Willebrand factor (VWF) laboratory testing and full-length VWF gene sequencing was performed for all index cases and healthy control subjects in a central laboratory. Bleeding phenotype was characterized using the International Society on Thrombosis and Haemostasis bleeding assessment tool. At study entry, 64% of subjects had VWF antigen (VWF:Ag) or VWF ristocetin cofactor activity below the lower limit of normal, whereas 36% had normal VWF levels. VWF sequence variations were most frequent in subjects with VWF:Ag <30 IU/dL (82%), whereas subjects with type 1 VWD and VWF:Ag ≥30 IU/dL had an intermediate frequency of variants (44%). Subjects whose VWF testing was normal at study entry had a similar rate of sequence variations as the healthy controls (14%). All subjects with severe type 1 VWD and VWF:Ag ≤5 IU/dL had an abnormal bleeding score (BS), but otherwise BS did not correlate with VWF:Ag. Subjects with a historical diagnosis of type 1 VWD had similar rates of abnormal BS compared with subjects with low VWF levels at study entry. Type 1 VWD in the United States is highly variable, and bleeding symptoms are frequent in this population. PMID:26862110

  20. Clinical and laboratory variability in a cohort of patients diagnosed with type 1 VWD in the United States.

    PubMed

    Flood, Veronica H; Christopherson, Pamela A; Gill, Joan Cox; Friedman, Kenneth D; Haberichter, Sandra L; Bellissimo, Daniel B; Udani, Rupa A; Dasgupta, Mahua; Hoffmann, Raymond G; Ragni, Margaret V; Shapiro, Amy D; Lusher, Jeanne M; Lentz, Steven R; Abshire, Thomas C; Leissinger, Cindy; Hoots, W Keith; Manco-Johnson, Marilyn J; Gruppo, Ralph A; Boggio, Lisa N; Montgomery, Kate T; Goodeve, Anne C; James, Paula D; Lillicrap, David; Peake, Ian R; Montgomery, Robert R

    2016-05-19

    von Willebrand disease (VWD) is the most common inherited bleeding disorder, and type 1 VWD is the most common VWD variant. Despite its frequency, diagnosis of type 1 VWD remains the subject of debate. In order to study the spectrum of type 1 VWD in the United States, the Zimmerman Program enrolled 482 subjects with a previous diagnosis of type 1 VWD without stringent laboratory diagnostic criteria. von Willebrand factor (VWF) laboratory testing and full-length VWF gene sequencing was performed for all index cases and healthy control subjects in a central laboratory. Bleeding phenotype was characterized using the International Society on Thrombosis and Haemostasis bleeding assessment tool. At study entry, 64% of subjects had VWF antigen (VWF:Ag) or VWF ristocetin cofactor activity below the lower limit of normal, whereas 36% had normal VWF levels. VWF sequence variations were most frequent in subjects with VWF:Ag <30 IU/dL (82%), whereas subjects with type 1 VWD and VWF:Ag ≥30 IU/dL had an intermediate frequency of variants (44%). Subjects whose VWF testing was normal at study entry had a similar rate of sequence variations as the healthy controls (14%). All subjects with severe type 1 VWD and VWF:Ag ≤5 IU/dL had an abnormal bleeding score (BS), but otherwise BS did not correlate with VWF:Ag. Subjects with a historical diagnosis of type 1 VWD had similar rates of abnormal BS compared with subjects with low VWF levels at study entry. Type 1 VWD in the United States is highly variable, and bleeding symptoms are frequent in this population. © 2016 by The American Society of Hematology.

  1. 48 CFR 3036.104-90 - Authority for one-step turn-key design-build contracting for the United States Coast Guard (USCG).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 7 2014-10-01 2014-10-01 false Authority for one-step turn-key design-build contracting for the United States Coast Guard (USCG). 3036.104-90 Section 3036.104-90 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND SECURITY ACQUISITION REGULATION (HSAR) SPECIAL CATEGORIES OF...

  2. KEY COMPARISON: Final report of International Comparison EUROMET.QM-K1c: Comparison of measurements of nitrogen monoxide in nitrogen

    NASA Astrophysics Data System (ADS)

    van der Veen, A. M. H.; Nieuwenkamp, G.; Oudwater, R.; Wessel, R. M.; Novak, J.; Perrochet, J.-F.; Ackermann, A.; Rakowska, A.; Cortez, L.; Dias, F.; Konopelko, L.; Kustikov, Y.; Sutour, C.; Masé, T.; Milton, M. J. T.; Uprichard, I. J.; Woods, P. T.; Walden, J.; Lopez Esteban, M. T.

    2005-01-01

    Following-up the key comparison CCQM-K1c, EUROMET organized a regional key comparison involving ten laboratories. The objectives of this EUROMET key comparison were essentially the same as for the CCQM-K1c comparison: to compare the measurement capabilities of national metrological institutes (NMIs) in measuring amount of substance fractions of nitrogen monoxide in nitrogen. The nominal amount of substance fraction of the standards used for the comparison was 100 µmol/mol. The pilot laboratory in this key comparison also piloted the CCQM key comparison and has long-term experience in the behaviour of these mixtures and the technical challenges in preparing batches of very similar mixtures. Most participants used chemiluminescence as the measurement method; two participants used UV techniques and one ND-IR. The degrees of equivalence between this comparison and CCQM-K1c were calculated; four laboratories participated in both key comparisons, thus providing sufficient data for demonstrating the comparability. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the Mutual Recognition Arrangement (MRA).

  3. Laboratory Needs for Interstellar Ice Studies

    NASA Astrophysics Data System (ADS)

    Boogert, Abraham C. A.

    2012-05-01

    A large fraction of the molecules in dense interstellar and circumstellar environments is stored in icy grain mantles. The mantles are formed by a complex interplay between chemical and physical processes. Key questions on the accretion and desorption processes and the chemistry on the grain surfaces and within the icy mantles can only be answered by laboratory experiments. Recent infrared (2-30 micron) spectroscopic surveys of large samples of Young Stellar Objects (YSOs) and background stars tracing quiescent cloud material have shown that the ice band profiles and depths vary considerably as a function of environment. Using laboratory spectra in the identification process, it is clear that a rather complex mixture of simple species (CH3OH, CO2, H2O, CO) exists even in the quiescent cloud phase. Variations of the local physical conditions (CO freeze out) and time scales (CH3OH formation) appear to be key factors in the observed variations. Sublimation and thermal processing dominate as YSOs heat their environments. The identification of several ice absorption features is still disputed. I will outline laboratory work (e.g., on salts, PAHs, and aliphatic hydrocarbons) needed to further constrain the ice band identification as well as the thermal and chemical history of the carriers. Such experiments will also be essential to interpret future high spectral resolution SOFIA and JWST observations.

  4. KEY COMPARISON: Key comparison CCQM-K60: Total selenium and selenomethionine in selenised wheat flour

    NASA Astrophysics Data System (ADS)

    Goenaga Infante, Heidi; Sargent, Mike

    2010-01-01

    Key comparison CCQM-K60 was performed to assess the analytical capabilities of national metrology institutes (NMIs) to accurately quantitate the mass fraction of selenomethionine (SeMet) and total selenium (at low mg kg-1 levels) in selenised wheat flour. It was organized by the Inorganic Analysis Working Group (IAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) as a follow-up key comparison to the previous pilot study CCQM-P86 on selenised yeast tablets. LGC Limited (Teddington, UK) and the Institute for National Measurement Standards, National Research Council Canada (NRCC, Ottawa, Canada) acted as the coordinating laboratories. CCQM-K60 was organized in parallel with a pilot study (CCQM-P86.1) involving not only NMIs but also expert laboratories worldwide, thus enabling them to assess their capabilities, discover problems and learn how to modify analytical procedures accordingly. Nine results for total Se and four results for SeMet were reported by the participant NMIs. Methods used for sample preparation were microwave assisted acid digestion for total Se and multiple-step enzymatic hydrolysis and hydrolysis with methanesulfonic acid for SeMet. For total Se, detection techniques included inductively coupled plasma mass spectrometry (ICP-MS) with external calibration, standard additions or isotope dilution analysis (IDMS); instrumental neutron activation analysis (INAA); and graphite furnace atomic absorption spectrometry (GFAAS) with external calibration. For determination of SeMet in the wheat flour sample, the four NMIs relied upon measurements using species-specific IDMS (using 76Se-enriched SeMet) with HPLC-ICP-MS. Eight of the nine participating NMIs reported results for total Se within 3.5% deviation from the key comparison reference value (KCRV). For SeMet, the four participating NMIs reported results within 3.2% deviation from the KCRV. This shows that the performance of the majority of the CCQM-K60 participants was very good

  5. Safety in the Chemical Laboratory: Contracts to Dispose of Laboratory Waste.

    ERIC Educational Resources Information Center

    Fischer, Kenneth E.

    1985-01-01

    Presents a sample contract for disposing of hazardous wastes in an environmentally sound, timely manner in accordance with all federal, state, and local requirements. Addresses situations where hazardous waste must be disposed of outside the laboratory and where alternate disposal methods are not feasible. (JN)

  6. KEY COMPARISON: Final report of the SIM 60Co air-kerma comparison SIM.RI(I)-K1

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co air kerma maintained by seven laboratories. Six of the laboratories are members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh is the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty of the comparison between any pair of laboratories ranged from 0.5% to 1.0%. The largest discrepancy between any two laboratories was 1.0%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  7. Protonation states of histidine and other key residues in deoxy normal human adult hemoglobin by neutron protein crystallography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kovalevsky, Andrey, E-mail: ayk@lanl.gov; Chatake, Toshiyuki; Shibayama, Naoya

    2010-11-01

    Using neutron diffraction analysis, the protonation states of 35 of 38 histidine residues were determined for the deoxy form of normal human adult hemoglobin. Distal and buried histidines may contribute to the increased affinity of the deoxy state for hydrogen ions and its decreased affinity for oxygen compared with the oxygenated form. The protonation states of the histidine residues key to the function of deoxy (T-state) human hemoglobin have been investigated using neutron protein crystallography. These residues can reversibly bind protons, thereby regulating the oxygen affinity of hemoglobin. By examining the OMIT F{sub o} − F{sub c} and 2F{sub o}more » − F{sub c} neutron scattering maps, the protonation states of 35 of the 38 His residues were directly determined. The remaining three residues were found to be disordered. Surprisingly, seven pairs of His residues from equivalent α or β chains, αHis20, αHis50, αHis58, αHis89, βHis63, βHis143 and βHis146, have different protonation states. The protonation of distal His residues in the α{sub 1}β{sub 1} heterodimer and the protonation of αHis103 in both subunits demonstrates that these residues may participate in buffering hydrogen ions and may influence the oxygen binding. The observed protonation states of His residues are compared with their ΔpK{sub a} between the deoxy and oxy states. Examination of inter-subunit interfaces provided evidence for interactions that are essential for the stability of the deoxy tertiary structure.« less

  8. The Master level optics laboratory at the Institute of Optics

    NASA Astrophysics Data System (ADS)

    Adamson, Per

    2017-08-01

    The master level optics laboratory is a biannual, intensive laboratory course in the fields of geometrical, physical and modern optics. This course is intended for the master level student though Ph.D. advisors which often recommend it to their advisees. The students are required to complete five standard laboratory experiments and an independent project during a semester. The goals of the laboratory experiments are for the students to get hands-on experience setting up optical laboratory equipment, collecting and analyzing data, as well as to communicate key results. The experimental methods, analysis, and results of the standard experiments are submitted in a journal style report, while an oral presentation is given for the independent project.

  9. Quantum-key-distribution protocol with pseudorandom bases

    NASA Astrophysics Data System (ADS)

    Trushechkin, A. S.; Tregubov, P. A.; Kiktenko, E. O.; Kurochkin, Y. V.; Fedorov, A. K.

    2018-01-01

    Quantum key distribution (QKD) offers a way for establishing information-theoretical secure communications. An important part of QKD technology is a high-quality random number generator for the quantum-state preparation and for post-processing procedures. In this work, we consider a class of prepare-and-measure QKD protocols, utilizing additional pseudorandomness in the preparation of quantum states. We study one of such protocols and analyze its security against the intercept-resend attack. We demonstrate that, for single-photon sources, the considered protocol gives better secret key rates than the BB84 and the asymmetric BB84 protocols. However, the protocol strongly requires single-photon sources.

  10. Final report of the key comparison of APMP.AUV.V-K2

    NASA Astrophysics Data System (ADS)

    Usuda, Takashi; Ota, Akihiro; Nozato, Hideaki; Ishigami, Tamio; Kokuyama, Wataru; Plangsangmas, Virat; Rattanangkul, Pairoj; Yih Tsuei, Kuang; Huang, Yu-Chung; Chee Keong, Chan; Shan, Cui

    2017-01-01

    A key comparison of vibration acceleration APMP.AUV.V-K2, which is an upgrade from APMP.AUV.V-K1.1, has been made within the Asia Pacific Metrology Programme (APMP) to include three national laboratories; the CMS-ITRI (Chinese Taipei), the NIMT (Thailand) and the A*Star (Singapore). One pilot laboratory, the NMIJ (Japan), participated to link the RMO APMP results to the CIPM CC key comparison (CCAUV.V-K2), according to the decision of the CCAUV10/D7 during the 10th CCAUV meeting. The admissible acceleration amplitude ranges from 10 m/s2 to 200 m/s2 over the frequency range from 40 Hz to 5 kHz. The RMO APMP results demonstrate the agreement with the key comparison reference value of CCAUV.V-K2 within the expanded uncertainties considering the armature effect of vibration exciter in a high-frequency range. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. U.S. Ebola Treatment Center Clinical Laboratory Support.

    PubMed

    Jelden, Katelyn C; Iwen, Peter C; Herstein, Jocelyn J; Biddinger, Paul D; Kraft, Colleen S; Saiman, Lisa; Smith, Philip W; Hewlett, Angela L; Gibbs, Shawn G; Lowe, John J

    2016-04-01

    Fifty-five hospitals in the United States have been designated Ebola treatment centers (ETCs) by their state and local health authorities. Designated ETCs must have appropriate plans to manage a patient with confirmed Ebola virus disease (EVD) for the full duration of illness and must have these plans assessed through a CDC site visit conducted by an interdisciplinary team of subject matter experts. This study determined the clinical laboratory capabilities of these ETCs. ETCs were electronically surveyed on clinical laboratory characteristics. Survey responses were returned from 47 ETCs (85%). Forty-one (87%) of the ETCs planned to provide some laboratory support (e.g., point-of-care [POC] testing) within the room of the isolated patient. Forty-four (94%) ETCs indicated that their hospital would also provide clinical laboratory support for patient care. Twenty-two (50%) of these ETC clinical laboratories had biosafety level 3 (BSL-3) containment. Of all respondents, 34 (72%) were supported by their jurisdictional public health laboratory (PHL), all of which had available BSL-3 laboratories. Overall, 40 of 44 (91%) ETCs reported BSL-3 laboratory support via their clinical laboratory and/or PHL. This survey provided a snapshot of the laboratory support for designated U.S. ETCs. ETCs have approached high-level isolation critical care with laboratory support in close proximity to the patient room and by distributing laboratory support among laboratory resources. Experts might review safety considerations for these laboratory testing/diagnostic activities that are novel in the context of biocontainment care. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  12. U.S. Ebola Treatment Center Clinical Laboratory Support

    PubMed Central

    Jelden, Katelyn C.; Iwen, Peter C.; Herstein, Jocelyn J.; Biddinger, Paul D.; Kraft, Colleen S.; Saiman, Lisa; Smith, Philip W.; Hewlett, Angela L.; Gibbs, Shawn G.

    2016-01-01

    Fifty-five hospitals in the United States have been designated Ebola treatment centers (ETCs) by their state and local health authorities. Designated ETCs must have appropriate plans to manage a patient with confirmed Ebola virus disease (EVD) for the full duration of illness and must have these plans assessed through a CDC site visit conducted by an interdisciplinary team of subject matter experts. This study determined the clinical laboratory capabilities of these ETCs. ETCs were electronically surveyed on clinical laboratory characteristics. Survey responses were returned from 47 ETCs (85%). Forty-one (87%) of the ETCs planned to provide some laboratory support (e.g., point-of-care [POC] testing) within the room of the isolated patient. Forty-four (94%) ETCs indicated that their hospital would also provide clinical laboratory support for patient care. Twenty-two (50%) of these ETC clinical laboratories had biosafety level 3 (BSL-3) containment. Of all respondents, 34 (72%) were supported by their jurisdictional public health laboratory (PHL), all of which had available BSL-3 laboratories. Overall, 40 of 44 (91%) ETCs reported BSL-3 laboratory support via their clinical laboratory and/or PHL. This survey provided a snapshot of the laboratory support for designated U.S. ETCs. ETCs have approached high-level isolation critical care with laboratory support in close proximity to the patient room and by distributing laboratory support among laboratory resources. Experts might review safety considerations for these laboratory testing/diagnostic activities that are novel in the context of biocontainment care. PMID:26842705

  13. Nuclear energy related capabilities at Sandia National Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pickering, Susan Y.

    2014-02-01

    Sandia National Laboratories' technology solutions are depended on to solve national and global threats to peace and freedom. Through science and technology, people, infrastructure, and partnerships, part of Sandia's mission is to meet the national needs in the areas of energy, climate and infrastructure security. Within this mission to ensure clean, abundant, and affordable energy and water is the Nuclear Energy and Fuel Cycle Programs. The Nuclear Energy and Fuel Cycle Programs have a broad range of capabilities, with both physical facilities and intellectual expertise. These resources are brought to bear upon the key scientific and engineering challenges facing themore » nation and can be made available to address the research needs of others. Sandia can support the safe, secure, reliable, and sustainable use of nuclear power worldwide by incorporating state-of-the-art technologies in safety, security, nonproliferation, transportation, modeling, repository science, and system demonstrations.« less

  14. 48 CFR 3036.104-90 - Authority for one-step turn-key design-build contracting for the United States Coast Guard (USCG).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Authority for one-step... General 3036.104-90 Authority for one-step turn-key design-build contracting for the United States Coast Guard (USCG). The Head of the Contracting Activity (HCA) of the U.S. Coast Guard may use one-step turn...

  15. The Nature of Laboratory Learning Experiences in Secondary Science Online

    NASA Astrophysics Data System (ADS)

    Crippen, Kent J.; Archambault, Leanna M.; Kern, Cindy L.

    2013-06-01

    Teaching science to secondary students in an online environment is a growing international trend. Despite this trend, reports of empirical studies of this phenomenon are noticeably missing. With a survey concerning the nature of laboratory activities, this study describes the perspective of 35-secondary teachers from 15-different U.S. states who are teaching science online. The type and frequency of reported laboratory activities are consistent with the tradition of face-to-face instruction, using hands-on and simulated experiments. While provided examples were student-centered and required the collection of data, they failed to illustrate key components of the nature of science. The features of student-teacher interactions, student engagement, and nonverbal communications were found to be lacking and likely constitute barriers to the enactment of inquiry. These results serve as a call for research and development focused on using existing communication tools to better align with the activity of science such that the nature of science is more clearly addressed, the work of students becomes more collaborative and authentic, and the formative elements of a scientific inquiry are more accessible to all participants.

  16. An active-learning laboratory on immunizations.

    PubMed

    Donohoe, Krista L; Mawyer, Tonya M; Stevens, J Tyler; Morgan, Laura A; Harpe, Spencer E

    2012-12-12

    To implement and evaluate an active-learning laboratory activity to teach pharmacy students about influenza, pneumococcal, and shingles vaccines. The laboratory session was divided into 6 immunization stations: 3 stations on influenza including a pediatrics station, and 1 station each for pneumococcal, shingles, and anaphylaxis. Although 118 of 123 (95.9%) students had completed an immunization training certificate prior to attending the laboratory, the average score on a pre-assessment to measure immunization knowledge and confidence was 56%. The post-assessment score was 87.4%. Students' confidence improved by 18.7% to 51.2% in each of the 5 areas assessed. Most respondents rated the activity overall as good or excellent on a post-activity evaluation. An active-learning approach to teaching immunizations allowed students to gain knowledge in simulated real-world experiences and reinforced key concepts on influenza, pneumococcal, and shingles vaccines.

  17. Quantum information transmission in the quantum wireless multihop network based on Werner state

    NASA Astrophysics Data System (ADS)

    Shi, Li-Hui; Yu, Xu-Tao; Cai, Xiao-Fei; Gong, Yan-Xiao; Zhang, Zai-Chen

    2015-05-01

    Many previous studies about teleportation are based on pure state. Study of quantum channel as mixed state is more realistic but complicated as pure states degenerate into mixed states by interaction with environment, and the Werner state plays an important role in the study of the mixed state. In this paper, the quantum wireless multihop network is proposed and the information is transmitted hop by hop through teleportation. We deduce a specific expression of the recovered state not only after one-hop teleportation but also across multiple intermediate nodes based on Werner state in a quantum wireless multihop network. We also obtain the fidelity of multihop teleportation. Project supported by the Prospective Future Network Project of Jiangsu Province, China (Grant No. BY2013095-1-18) and the Independent Project of State Key Laboratory of Millimeter Waves (Grant No. Z201504).

  18. Laboratory Automation and Intra-Laboratory Turnaround Time: Experience at the University Hospital Campus Bio-Medico of Rome.

    PubMed

    Angeletti, Silvia; De Cesaris, Marina; Hart, Jonathan George; Urbano, Michele; Vitali, Massimiliano Andrea; Fragliasso, Fulvio; Dicuonzo, Giordano

    2015-12-01

    Intra-laboratory turnaround time (TAT) is a key indicator of laboratory performance. Improving TAT is a complex task requiring staff education, equipment acquisition, and adequate TAT monitoring. The aim of the present study was to evaluate the intra-laboratory TAT after laboratory automation implementation (June 2013-June 2014) and to compare it to that in the preautomation period (July 2012-May 2013). Intra-laboratory TAT was evaluated both as the mean TAT registered and the percentage of outlier (OP) exams. The mean TAT was 36, 38, and 34 min during the study periods, respectively. These values respected the goal TAT established at 45 min. The OP, calculated at 45 min as well as at 60 min, decreased from 26 to 21 and from 11 to 5, respectively. From a focused analysis on blood count cell, troponin I, and prothrombin (PT) test, TAT improvement was more evident for tests requiring longer preanalytical process. The follow-up of TAT from June 2013 to June 2014 revealed the reduction of the mean TAT as well as of the OP exams after automation implementation and that automation more strongly affects the test in the preanalytical phase including centrifugation of the sample, such as troponin I and PT. © 2015 Society for Laboratory Automation and Screening.

  19. Laboratory Astrophysics White Paper

    NASA Technical Reports Server (NTRS)

    Brickhouse, Nancy; Federman, Steve; Kwong, Victor; Salama, Farid; Savin, Daniel; Stancil, Phillip; Weingartner, Joe; Ziurys, Lucy

    2006-01-01

    Laboratory astrophysics and complementary theoretical calculations are the foundations of astronomical and planetary research and will remain so for many generations to come. From the level of scientific conception to that of the scientific return, it is our understanding of the underlying processes that allows us to address fundamental questions regarding the origins and evolution of galaxies, stars, planetary systems, and life in the cosmos. In this regard, laboratory astrophysics is much like detector and instrument development at NASA and NSF; these efforts are necessary for the astronomical research being funded by the agencies. The NASA Laboratory Astrophysics Workshop met at the University of Nevada, Las Vegas (UNLV) from 14-16 February, 2006 to identify the current laboratory data needed to support existing and future NASA missions and programs in the Astrophysics Division of the Science Mission Directorate (SMD). Here we refer to both laboratory and theoretical work as laboratory astrophysics unless a distinction is necessary. The format for the Workshop involved invited talks by users of laboratory data, shorter contributed talks and poster presentations by both users and providers that highlighted exciting developments in laboratory astrophysics, and breakout sessions where users and providers discussed each others' needs and limitations. We also note that the members of the Scientific Organizing Committee are users as well as providers of laboratory data. As in previous workshops, the focus was on atomic, molecular, and solid state physics.

  20. 42 CFR 493.555 - Federal review of laboratory requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Federal review of laboratory requirements. 493.555... SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Accreditation by a Private, Nonprofit Accreditation Organization or Exemption Under an Approved State Laboratory Program § 493.555...

  1. 42 CFR 493.555 - Federal review of laboratory requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Federal review of laboratory requirements. 493.555... SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Accreditation by a Private, Nonprofit Accreditation Organization or Exemption Under an Approved State Laboratory Program § 493.555...

  2. National Water Quality Laboratory Profile

    USGS Publications Warehouse

    Raese, Jon W.

    1994-01-01

    The National Water Quality Laboratory determines organic and inorganic constituents in samples of surface and ground water, river and lake sediment, aquatic plant and animal material, and precipitation collected throughout the United States and its territories by the U.S. Geological Survey. In water year 1994, the Laboratory produced more than 900,000 analytical results for about 65,000 samples. The Laboratory also coordinates an extensive network of contract laboratories for the determination of radiochemical and stable isotopes and work for the U.S. Department of Defense Environmental Contamination Hydrology Program. Heightened concerns about water quality and about the possible effects of toxic chemicals at trace and ultratrace levels have contributed to an increased demand for impartial, objective, and independent data.

  3. Effects of gas periodic stimulation on key enzyme activity in gas double-dynamic solid state fermentation (GDD-SSF).

    PubMed

    Chen, Hongzhang; Shao, Meixue; Li, Hongqiang

    2014-03-05

    The heat and mass transfer have been proved to be the important factors in air pressure pulsation for cellulase production. However, as process of enzyme secretion, the cellulase formation has not been studied in the view of microorganism metabolism and metabolic key enzyme activity under air pressure pulsation condition. Two fermentation methods in ATPase activity, cellulase productivity, weight lose rate and membrane permeability were systematically compared. Results indicated that gas double-dynamic solid state fermentation had no obviously effect on cell membrane permeability. However, the relation between ATPase activity and weight loss rate was linearly dependent with r=0.9784. Meanwhile, the results also implied that gas periodic stimulation had apparently strengthened microbial metabolism through increasing ATPase activity during gas double-dynamic solid state fermentation, resulting in motivating the production of cellulase by Trichoderma reesei YG3. Therefore, the increase of ATPase activity would be another crucial factor to strengthen fermentation process for cellulase production under gas double-dynamic solid state fermentation. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. How can laboratory plasma experiments contribute to space and &astrophysics?

    NASA Astrophysics Data System (ADS)

    Yamada, M.

    Plasma physics plays key role in a wide range of phenomena in the universe, from laboratory plasmas to the magnetosphere, the solar corona, and to the tenuous interstellar and intergalactic gas. Despite the huge difference in physical scales, there are striking similarities in plasma behavior of laboratory and space plasmas. Similar plasma physics problems have been investigated independently by both laboratory plasma physicists and astrophysicists. Since 1991, cross fertilization has been increased among laboratory plasma physicists and space physicists through meeting such as IPELS [Interrelationship between Plasma Experiments in the Laboratory and Space] meeting. The advances in laboratory plasma physics, along with the recent surge of astronomical data from satellites, make this moment ripe for research collaboration to further advance plasma physics and to obtain new understanding of key space and astrophysical phenomena. The recent NRC review of astronomy and astrophysics notes the benefit that can accrue from stronger connection to plasma physics. The present talk discusses how laboratory plasma studies can contribute to the fundamental understandings of the space and astrophysical phenomena by covering common key physics topics such as magnetic reconnection, dynamos, angular momentum transport, ion heating, and magnetic self-organization. In particular, it has recently been recognized that "physics -issue- dedicated" laboratory experiments can contribute significantly to the understanding of the fundamental physics for space-astrophysical phenomena since they can create fundamental physics processes in controlled manner and provide well-correlated plasma parameters at multiple plasma locations simultaneously. Such dedicated experiments not only can bring about better understanding of the fundamental physics processes but also can lead to findings of new physics principles as well as new ideas for fusion plasma confinement. Several dedicated experiments have

  5. Translating a National Laboratory Strategic Plan into action through SLMTA in a district hospital laboratory in Botswana.

    PubMed

    Ntshambiwa, Keoratile; Ntabe-Jagwer, Winnie; Kefilwe, Chandapiwa; Samuel, Fredrick; Moyo, Sikhulile

    2014-01-01

    The Ministry of Health (MOH) of Botswana adopted Strengthening Laboratory Management Toward Accreditation (SLMTA), a structured quality improvement programme, as a key tool for the implementation of quality management systems in its public health laboratories. Coupled with focused mentorship, this programme aimed to help MOH achieve the goals of the National Laboratory Strategic Plan to provide quality and timely clinical diagnoses. This article describes the impact of implementing SLMTA in Sekgoma Memorial Hospital Laboratory (SMHL) in Serowe, Botswana. SLMTA implementation in SMHL included trainings, improvement projects, site visits and focused mentorship. To measure progress, audits using the Stepwise Laboratory Quality Improvement Process Towards Accreditation (SLIPTA) checklist were conducted at baseline and exit of the programme, with scores corresponding to a zero- to five-star scale. Turnaround times, customer satisfaction, and several other health service indicators were tracked. The laboratory scored 53% (zero stars) at the baseline audit and 80% (three stars) at exit. Nearly three years later, the laboratory scored 85% (four stars) in an official audit conducted by the African Society for Laboratory Medicine. Turnaround times became shorter after SLMTA implementation, with reductions ranging 19% to 52%; overall patient satisfaction increased from 56% to 73%; and clinician satisfaction increased from 41% to 72%. Improvements in inventory management led to decreases in discarded reagents, reducing losses from US $18 000 in 2011 to $40 in 2013. The SLMTA programme contributed to enhanced performance of the laboratory, which in turn yielded potential positive impacts for patient care at the hospital.

  6. Meta-analysis of the effectiveness of computer-based laboratory versus traditional hands-on laboratory in college and pre-college science instructions

    NASA Astrophysics Data System (ADS)

    Onuoha, Cajetan O.

    The purpose of this research study was to determine the overall effectiveness of computer-based laboratory compared with the traditional hands-on laboratory for improving students' science academic achievement and attitudes towards science subjects at the college and pre-college levels of education in the United States. Meta-analysis was used to synthesis the findings from 38 primary research studies conducted and/or reported in the United States between 1996 and 2006 that compared the effectiveness of computer-based laboratory with the traditional hands-on laboratory on measures related to science academic achievements and attitudes towards science subjects. The 38 primary research studies, with total subjects of 3,824 generated a total of 67 weighted individual effect sizes that were used in this meta-analysis. The study found that computer-based laboratory had small positive effect sizes over the traditional hands-on laboratory (ES = +0.26) on measures related to students' science academic achievements and attitudes towards science subjects (ES = +0.22). It was also found that computer-based laboratory produced more significant effects on physical science subjects compared to biological sciences (ES = +0.34, +0.17).

  7. A new species of Dicranophora Macquart (Diptera, Stratiomyidae) from Bahia State, Brazil and a key to species of the genus.

    PubMed

    De Godoi, Fabio Siqueira Pitaluga; Rafael, José Albertino

    2013-01-01

    A new species of the Neotropical Dicranophora Macquart is described and illustrated from six males collected in northeast Brazil, Bahia state (Encruzilhada district). Dicranophora femurspiculata sp. nov. is characterized by the specific pattern of spots on the frons, on the legs and on the abdomen, and by a distinct shape of the scutellar process and mid femur A key to the species of the genus and a distribution map are presented.

  8. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China.

    PubMed

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-01-01

    To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479/1307), 38% (228/598), and 36% (449/1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them.

  9. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China

    PubMed Central

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun

    2015-01-01

    Introduction To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. Materials and methods 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. Results The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479 / 1307), 38% (228 / 598), and 36% (449 / 1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Conclusions Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them. PMID:26110033

  10. United States Air Force Summer Research Program -- 1993. Volume 6. Arnold Engineering Development Center, Frank J. Seiler Research Laboratory, Wilford Hall Medical Center

    DTIC Science & Technology

    1993-12-01

    where negative charge state. The local symmetry of the Ge(I) and Ge(II) centers are CI and C2 respectively. (See also Fig. 1.) q=- 1 Ge(I) Ge(II) s p...Raymond Field: Dept. of Computer Science Dept, CEM. M•e s , PhD Laboratory: / 3200 Willow Creek Road zmbry-Riddle Aeronautical Univ Vol-Page No: 0- 0...Field: Electrical Engineering Assistant Professor, PhD Laboratory: PL/WS 2390 S . York Street University of Denver Vol-Page No: 3-35 Denver, CO 80209-0177

  11. Locally acquired Dengue--Key West, Florida, 2009-2010.

    PubMed

    2010-05-21

    Dengue is the most common vector-borne viral disease in the world, causing an estimated 50-100 million infections and 25,000 deaths each year. During 1946-1980, no cases of dengue acquired in the continental United States were reported. Since 1980, a few locally acquired U.S. cases have been confirmed along the Texas-Mexico border, temporally associated with large outbreaks in neighboring Mexican cities. On September 1, 2009, a New York physician notified the Monroe County (Florida) Health Department (MCHD) and the Florida Department of Health (FDOH) of a suspected dengue case in a New York state resident whose only recent travel was to Key West, Florida. CDC confirmed the diagnosis, and a press release was issued to notify the public and Key West physicians of the potential risk for locally acquired dengue infections. In the next 2 weeks, two dengue infections in Key West residents without recent travel were reported and confirmed. Subsequently, enhanced and active surveillance identified 24 more Key West cases during 2009. On April 13, 2010, another Key West dengue case was reported to FDOH, bringing the total to 28. This report describes the first three dengue cases reported in 2009, briefly summarizes the 2010 case, highlights preliminary findings from the ongoing investigation, and outlines measures used to mitigate and control the outbreak. Clinicians should include dengue in the differential diagnosis of acute febrile illnesses in patients who live in or have recently traveled to subtropical areas of the United States or to the tropics.

  12. Key Response Planning Factors for the Aftermath of Nuclear Terrorism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buddemeier, B R; Dillon, M B

    Despite hundreds of above-ground nuclear tests and data gathered from Hiroshima and Nagasaki, the effects of a ground-level, low-yield nuclear detonation in a modern urban environment are still the subject of considerable scientific debate. Extensive review of nuclear weapon effects studies and discussions with nuclear weapon effects experts from various federal agencies, national laboratories, and technical organizations have identified key issues and bounded some of the unknowns required to support response planning for a low-yield, ground-level nuclear detonation in a modern U.S. city. This study, which is focused primarily upon the hazards posed by radioactive fallout, used detailed fallout predictionsmore » from the advanced suite of three-dimensional (3-D) meteorology and plume/fallout models developed at Lawrence Livermore National Laboratory (LLNL), including extensive global Key Response Planning Factors for the Aftermath of Nuclear Terrorism geographical and real-time meteorological databases to support model calculations. This 3-D modeling system provides detailed simulations that account for complex meteorology and terrain effects. The results of initial modeling and analysis were presented to federal, state, and local working groups to obtain critical, broad-based review and feedback on strategy and messaging. This effort involved a diverse set of communities, including New York City, National Capitol Regions, Charlotte, Houston, Portland, and Los Angeles. The largest potential for reducing casualties during the post-detonation response phase comes from reducing exposure to fallout radiation. This can be accomplished through early, adequate sheltering followed by informed, delayed evacuation.B The response challenges to a nuclear detonation must be solved through multiple approaches of public education, planning, and rapid response actions. Because the successful response will require extensive coordination of a large number of organizations

  13. Iowa Central Quality Fuel Testing Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heach, Don; Bidieman, Julaine

    2013-09-30

    The objective of this project is to finalize the creation of an independent quality fuel testing laboratory on the campus of Iowa Central Community College in Fort Dodge, Iowa that shall provide the exploding biofuels industry a timely and cost-effective centrally located laboratory to complete all state and federal fuel and related tests that are required. The recipient shall work with various state regulatory agencies, biofuel companies and state and national industry associations to ensure that training and testing needs of their members and American consumers are met. The recipient shall work with the Iowa Department of Ag and Landmore » Stewardship on the development of an Iowa Biofuel Quality Standard along with the Development of a standard that can be used throughout industry.« less

  14. KEY COMPARISON: CCQM-K25: Determination of PCB congeners in sediment

    NASA Astrophysics Data System (ADS)

    Schantz, Michele; Wise, Stephen

    2004-01-01

    Polychlorinated biphenyls (PCBs) consist of 209 possible congeners depending on the substitution of the chlorine atoms around the biphenyl molecule. PCBs have been widely used as industrial fluids, flame retardants, diluents, hydraulic fluids, and dielectric fluids for capacitors and transformers. As a class of compounds, they are environmentally stable and tend to bioaccumulate. Of the 209 possible congeners, approximately 150 congeners have been reported in the environment. Congener-specific PCB methods, which are typically based on gas chromatography (GC) with electron capture detection (ECD) or mass spectrometric (MS) detection, are designed to measure selected priority congeners, but the congeners of interest change with the study and sponsoring agency. A pilot study (CCQM-P17) for the determination of PCB congeners in sediment was organized by NIST and NRC-Canada in 2000. Ten laboratories participated in the pilot study. After discussion and critical review of the data, there was agreement that the pilot study should be followed by a Key Comparison and that the Key Comparison Reference Value (KCRV) should be derived from isotope dilution GC/MS (ID-GC/MS) based methods that had been validated in the Pilot Study. The CCQM-K25 Key Comparison study utilized a sediment sample prepared by mixing known quantities of two sediment materials to simulate a moderately contaminated sample with respect to PCBs. Nine laboratories participated in CCQM-K25 and demonstrated a high level of equivalence in capabilities for determining five PCB congeners (congener numbers 28, 101, 105, 153, and 170) in a moderately contaminated sediment using GC/MS-based methods. The amount of substance concentration for the congeners measured ranged from ~10 ng/g to ~35 ng/g. The relative expanded uncertainties of the KCRVs ranged from 2% to 5%, indicating excellent agreement among the participants that used ID-GC/MS. Results from the one laboratory that used GC/MS with a non-labeled PCB

  15. Simple 2.5 GHz time-bin quantum key distribution

    NASA Astrophysics Data System (ADS)

    Boaron, Alberto; Korzh, Boris; Houlmann, Raphael; Boso, Gianluca; Rusca, Davide; Gray, Stuart; Li, Ming-Jun; Nolan, Daniel; Martin, Anthony; Zbinden, Hugo

    2018-04-01

    We present a 2.5 GHz quantum key distribution setup with the emphasis on a simple experimental realization. It features a three-state time-bin protocol based on a pulsed diode laser and a single intensity modulator. Implementing an efficient one-decoy scheme and finite-key analysis, we achieve record breaking secret key rates of 1.5 kbps over 200 km of standard optical fibers.

  16. USGS Scientific Visualization Laboratory

    USGS Publications Warehouse

    ,

    1995-01-01

    The U.S. Geological Survey's (USGS) Scientific Visualization Laboratory at the National Center in Reston, Va., provides a central facility where USGS employees can use state-of-the-art equipment for projects ranging from presentation graphics preparation to complex visual representations of scientific data. Equipment including color printers, black-and-white and color scanners, film recorders, video equipment, and DOS, Apple Macintosh, and UNIX platforms with software are available for both technical and nontechnical users. The laboratory staff provides assistance and demonstrations in the use of the hardware and software products.

  17. KEY COMPARISON: Results of the APMP Pressure key comparison APMP.M.P-K1c in gas media and gauge mode from 0.4 MPa to 4.0 MPa

    NASA Astrophysics Data System (ADS)

    Bandyopadhyay, A. K.; Woo, Sam Yong; Fitzgerald, Mark; Man, John; Ooiwa, Akira; Jescheck, M.; Jian, Wu; Fatt, Chen Soo; Chan, T. K.; Moore, Ken; El-Tawil, Alaaeldin A. E.

    2003-01-01

    This report summarizes the results of a regional key comparison (APMP-IC-2-97) under the aegis of the Asia Pacific Metrology Program (APMP) for pressure measurements in gas media and in gauge mode from 0.4 MPa to 4.0 MPa. The transfer standard was a pressure-balance with a piston-cylinder assembly with nominal effective area 8.4 mm2 (V-407) and was supplied by the National Metrology Institute of Japan [NMIJ]. Ten standard laboratories from the APMP region with one specially invited laboratory from the EUROMET region, namely Physikalisch-Technische Bundesanstalt (PTB), Germany, participated in this comparison. The comparison started in October 1998 and was completed in May 2001. The pilot laboratory prepared the calibration procedure [1] as per the guidelines of APMP and the International Bureau of Weights and Measures (BIPM) [2-4]. Detailed instructions for performing this key comparison were provided in the calibration protocol [1] and the required data were described in: (1) Annex 3 - characteristics of the laboratory standards, (2) Annex 4 - the effective area (A'p'/mm2) (the prime indicates values based on measured quantities) at 23°C of the travelling standard as a function of nominal pressure (p'/MPa) (five cycles both increasing and decreasing pressures at ten pre-determined pressure points) and (3) Annex 5 - the average effective area at 23°C (A'p'/mm2) obtained for each pressure p'/MPa with all uncertainty statements. The pilot laboratory processed the information and the data provided by the participants for these three annexes, starting with the information about the standards as provided in Annex 3. Based on this information, the participating laboratories are classified into two categories: (I) laboratories that are maintaining primary standards, and (II) laboratories that are maintaining standards loosely classified as secondary standards with a clear traceability as per norm of the BIPM. It is observed that out of these eleven laboratories, six

  18. Key Skills Influencing Student Achievement

    ERIC Educational Resources Information Center

    Balch, Tonya; Gruenert, Steve

    2009-01-01

    A predictive, non-experimental, cross-sectional design (Johnson, 2001) was used to conduct a study to determine if elementary administrators' key counseling skills and select demographics predicted state-level student performance indicators in their respective schools. A secondary purpose of this study was to develop a valid and reliable on-line…

  19. Coupled laboratory experiments and numerical models for generating ice-depth profiles of steady-state hydrogen peroxide concentrations on radiolytically processed icy worlds.

    NASA Astrophysics Data System (ADS)

    Hand, K. P.; Carlson, R. W.

    2007-12-01

    The presence of hydrogen peroxide and condensed phase molecular oxygen on the surface of Europa is now well established [1,2] and laboratory experiments have repeatedly demonstrated the viability of various radiolytic processes for explaining the observations [see e.g. 3, 4]. To date, however, both the Europa observations and the laboratory work have been limited to only the upper few, or few tens of microns, of ice. The spectrum of charged particles incident on the surface of Europa penetrates deeper, and deposits energy over a much greater range, than any laboratory experiment has aimed to replicate [5, 6]. Here we present results from laboratory work on hydrogen peroxide production using energetic electrons (4 keV - 16 keV) and couple these results with a numerical model for the integrated steady-state density of hydrogen peroxide as a function of depth into the ice. Production rates and steady-state peroxide levels for a range of initial electron energies are used to generate functions for the number of peroxide molecules produced per initial electron as it penetrates through the ice. We examined the electron energy spectrum from 0.01 MeV to 10 MeV and accounted for electrons incident to the surface over the solid angle from cosine(theta) = 0.3-1.0, where theta is the angle from the normal to the surface. We found that, accounting for production and destruction as a function of energy deposition, steady-state hydrogen peroxide concentrations resulting from electron radiolysis likely increases by a factor of a few to an order of magnitude at a depth of a few hundred microns. In other words, the 0.13 percent by number abundance of peroxide observed by NIMS [1] may be a low-end value; at depth the peroxide concentration could increase to a few percent by number relative to water. [1] Carlson et al. 1999. [2] Spencer and Calvin, 2002. [3] Moore and Hudson, 2000. [4] Loeffler et al., 2006. [5] Cooper et al., 2001 [6] Paranicas et al., 2001.

  20. Practical issues in quantum-key-distribution postprocessing

    NASA Astrophysics Data System (ADS)

    Fung, Chi-Hang Fred; Ma, Xiongfeng; Chau, H. F.

    2010-01-01

    Quantum key distribution (QKD) is a secure key generation method between two distant parties by wisely exploiting properties of quantum mechanics. In QKD, experimental measurement outcomes on quantum states are transformed by the two parties to a secret key. This transformation is composed of many logical steps (as guided by security proofs), which together will ultimately determine the length of the final secret key and its security. We detail the procedure for performing such classical postprocessing taking into account practical concerns (including the finite-size effect and authentication and encryption for classical communications). This procedure is directly applicable to realistic QKD experiments and thus serves as a recipe that specifies what postprocessing operations are needed and what the security level is for certain lengths of the keys. Our result is applicable to the BB84 protocol with a single or entangled photon source.

  1. Laboratory testing under managed care dominance in the USA

    PubMed Central

    Takemura, Y; Beck, J

    2001-01-01

    The uncontrolled escalation of total health care expenditure despite the government's endeavours during the past decades in the USA had led to the rapid infiltration of managed care organisations (MCOs). Traditional hospital based laboratories have been placed in a crucial situation with the advent of the managed care era. A massive reduction of in house testing urged them to develop strategies against financial difficulty. Consolidation and networking, participation in the outreach testing market, and emphasis on point of care/satellite laboratory testing in non-traditional, ambulatory settings are major strategies for the survival of hospital laboratories. Several physicians' office laboratories (POLS) have closed their doors in response both to regulatory restrictions imposed by the Clinical Laboratory Improvement Amendments of 1988 and to managed care infiltration. It seems likely that POLs and hospital laboratories will continue to reduce test volumes, whereas commercial reference laboratories will thrive through contracting with MCOs. In the current climate of managed care dominance in the USA, clinical laboratories are changing their basic operation focus and mission in response to the aggressively changing landscape. Key Words: laboratory testing • managed care organisations • survival strategies PMID:11215291

  2. The Undecided Have the Key: Interaction-Driven Opinion Dynamics in a Three State Model

    PubMed Central

    2015-01-01

    The effects of interpersonal interactions on individual’s agreements result in a social aggregation process which is reflected in the formation of collective states, as for instance, groups of individuals with a similar opinion about a given issue. This field, which has been a longstanding concern of sociologists and psychologists, has been extended into an area of experimental social psychology, and even has attracted the attention of physicists and mathematicians. In this article, we present a novel model of opinion formation in which agents may either have a strict preference for a choice, or be undecided. The opinion shift emerges, in a threshold process, as a consequence of a cumulative persuasion for either one of the two opinions in repeated interactions. There are two main ingredients which play key roles in determining the steady states: the initial fraction of undecided agents and the change in agents’ persuasion after each interaction. As a function of these two parameters, the model presents a wide range of solutions, among which there are consensus of each opinion and bi-polarization. We found that a minimum fraction of undecided agents is not crucial for reaching consensus only, but also to determine a dominant opinion in a polarized situation. In order to gain a deeper comprehension of the dynamics, we also present the theoretical framework of the model. The master equations are of special interest for their nontrivial properties and difficulties in being solved analytically. PMID:26436421

  3. Understanding dynamic friction through spontaneously evolving laboratory earthquakes

    PubMed Central

    Rubino, V.; Rosakis, A. J.; Lapusta, N.

    2017-01-01

    Friction plays a key role in how ruptures unzip faults in the Earth’s crust and release waves that cause destructive shaking. Yet dynamic friction evolution is one of the biggest uncertainties in earthquake science. Here we report on novel measurements of evolving local friction during spontaneously developing mini-earthquakes in the laboratory, enabled by our ultrahigh speed full-field imaging technique. The technique captures the evolution of displacements, velocities and stresses of dynamic ruptures, whose rupture speed range from sub-Rayleigh to supershear. The observed friction has complex evolution, featuring initial velocity strengthening followed by substantial velocity weakening. Our measurements are consistent with rate-and-state friction formulations supplemented with flash heating but not with widely used slip-weakening friction laws. This study develops a new approach for measuring local evolution of dynamic friction and has important implications for understanding earthquake hazard since laws governing frictional resistance of faults are vital ingredients in physically-based predictive models of the earthquake source. PMID:28660876

  4. A Laboratory Experiment on the Statistical Theory of Nuclear Reactions

    ERIC Educational Resources Information Center

    Loveland, Walter

    1971-01-01

    Describes an undergraduate laboratory experiment on the statistical theory of nuclear reactions. The experiment involves measuring the relative cross sections for formation of a nucleus in its meta stable excited state and its ground state by applying gamma-ray spectroscopy to an irradiated sample. Involves 3-4 hours of laboratory time plus…

  5. Seaworthy Quantum Key Distribution Design and Validation (SEAKEY)

    DTIC Science & Technology

    2015-11-12

    polarization control and the CV state and the LO state are separated at a polarizing beam splitter . The CV state is delayed relative to the LO state, and... splitter or loss imperfections. We have identified a number of risks associated with implementing this design . The two most critical risks are: • The...Contractor Address: 10 Moulton Street, Cambridge, MA 02138 Title of the Project: Seaworthy Quantum Key Distribution Design and Validation (SEAKEY

  6. Final report on the torque key komparison CCM.T-K1.2 measurand torque: 0 N.m, 500 N.m, 1000 N.m

    NASA Astrophysics Data System (ADS)

    Röske, Dirk

    2015-01-01

    The purpose of the CIPM subsequent bilateral comparison CCM.T-K1.2 was to link another participant, namely the National Institute of Metrology (Thailand), in short NIMT, to the CCM.T-K1 torque key comparison. The measuring capabilities up to 1000 N.m of dead-weight torque standard machines with supported lever were investigated. The pilot laboratory was the same in both comparisons—it was the Physikalisch-Technische Bundesanstalt (PTB, Braunschweig, Germany). The same two very stable torque transducers with well-known properties were used as travelling standards. The measurements at the participating laboratory were carried out between November 2007 and February 2008. According to the technical protocol, torque steps of 500 N.m and 1000 N.m had to be measured both in clockwise and anticlockwise directions. Corrections had to be applied to the results reported by the participants taking into account the use of different amplifiers, the creep (due to different loading times of the machines) and the environmental conditions in the laboratories (temperature and relative humidity of the ambient air). The results of the pilot laboratory in this bilateral comparison are in very good agreement with the same results obtained in the CCM.T-K1 comparison. For each of the transducers, the two torque steps and both senses of direction of the torque vector, the key comparison reference value of the CCM.T-K1 was taken, and the results of participant NIMT were calculated with respect to these values. The agreement between the results is very good. The smallest expanded (k = 2) relative uncertainty of the machine stated by the participant is 1 × 10-4. The results of the comparison support this uncertainty statement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by CCM, according

  7. Education Savings Accounts: Key Provisions and State Variations. Education Trends

    ERIC Educational Resources Information Center

    Railey, Hunter

    2016-01-01

    In 2011, the Arizona State Legislature adopted a law creating the first education savings account (ESA) in the United States. Following Arizona's lead, several other states, including Florida Tennessee,Mississippi and Nevada, have implemented ESA policies. Typical eligibility requirements include conditions such as a pupil's diagnosed disability,…

  8. Practical gigahertz quantum key distribution robust against channel disturbance.

    PubMed

    Wang, Shuang; Chen, Wei; Yin, Zhen-Qiang; He, De-Yong; Hui, Cong; Hao, Peng-Lei; Fan-Yuan, Guan-Jie; Wang, Chao; Zhang, Li-Jun; Kuang, Jie; Liu, Shu-Feng; Zhou, Zheng; Wang, Yong-Gang; Guo, Guang-Can; Han, Zheng-Fu

    2018-05-01

    Quantum key distribution (QKD) provides an attractive solution for secure communication. However, channel disturbance severely limits its application when a QKD system is transferred from the laboratory to the field. Here a high-speed Faraday-Sagnac-Michelson QKD system is proposed that can automatically compensate for the channel polarization disturbance, which largely avoids the intermittency limitations of environment mutation. Over a 50 km fiber channel with 30 Hz polarization scrambling, the practicality of this phase-coding QKD system was characterized with an interference fringe visibility of 99.35% over 24 h and a stable secure key rate of 306 k bits/s over seven days without active polarization alignment.

  9. Key Facts about Higher Education in Washington: 2009-10

    ERIC Educational Resources Information Center

    Washington Higher Education Coordinating Board, 2010

    2010-01-01

    First published in 2002, "Key Facts about Higher Education in Washington" provides valuable information on the ways higher education serves the state and its people. The most current data and information available is presented throughout this report to highlight the "Key Facts" about Washington's postsecondary institutions,…

  10. Feasibility of satellite quantum key distribution

    NASA Astrophysics Data System (ADS)

    Bonato, C.; Tomaello, A.; Da Deppo, V.; Naletto, G.; Villoresi, P.

    2009-04-01

    In this paper, we present a novel analysis of the feasibility of quantum key distribution between a LEO satellite and a ground station. First of all, we study signal propagation through a turbulent atmosphere for uplinks and downlinks, discussing the contribution of beam spreading and beam wandering. Then we introduce a model for the background noise of the channel during night-time and day-time, calculating the signal-to-noise ratio for different configurations. We also discuss the expected error-rate due to imperfect polarization compensation in the channel. Finally, we calculate the expected key generation rate of a secure key for different configurations (uplink, downlink) and for different protocols (BB84 with and without decoy states, entanglement-based Ekert91 protocol).

  11. UK dental laboratory technicians' views on the efficacy and teaching of clinical-laboratory communication.

    PubMed

    Juszczyk, A S; Clark, R K F; Radford, D R

    2009-05-23

    The General Dental Council states that 'good dental care is delivered by a team' and restorative treatment is enhanced by communication between team members. Commercial dental laboratories are ideally placed to comment on effective communication. To investigate contemporary attitudes and communication between dentist and dental technician from the technician's perspective. Eight hundred and three dental laboratories were invited to take part in a postal survey covering dentist/laboratory communication and the dentist's understanding of technical procedures. Forty percent of laboratories responded. Only 9% scored communication as very good, 48% scored communication with newly qualified dentists better than with established dentists but only 26% considered that dental students were taught to communicate with dental laboratories effectively. The free comments that the respondents were invited to make identified three distinct themes, 'recognition within the dental team', 'effective communication between dentist and dental technician' and 'dentists lack of technical knowledge'. Effective communication between dentist and dental technician is often poor. It was the view of the dental technicians who responded that newly qualified dentists do not have an appropriate understanding of technical techniques. Dental schools are still not preparing new graduates to communicate effectively with dental laboratories.

  12. Total laboratory automation: Do stat tests still matter?

    PubMed

    Dolci, Alberto; Giavarina, Davide; Pasqualetti, Sara; Szőke, Dominika; Panteghini, Mauro

    2017-07-01

    During the past decades the healthcare systems have rapidly changed and today hospital care is primarily advocated for critical patients and acute treatments, for which laboratory test results are crucial and need to be always reported in predictably short turnaround time (TAT). Laboratories in the hospital setting can face this challenge by changing their organization from a compartmentalized laboratory department toward a decision making-based laboratory department. This requires the implementation of a core laboratory, that exploits total laboratory automation (TLA) using technological innovation in analytical platforms, track systems and information technology, including middleware, and a number of satellite specialized laboratory sections cooperating with care teams for specific medical conditions. In this laboratory department model, the short TAT for all first-line tests performed by TLA in the core laboratory represents the key paradigm, where no more stat testing is required because all samples are handled in real-time and (auto)validated results dispatched in a time that fulfills clinical needs. To optimally reach this goal, laboratories should be actively involved in managing all the steps covering the total examination process, speeding up also extra-laboratory phases, such sample delivery. Furthermore, to warrant effectiveness and not only efficiency, all the processes, e.g. specimen integrity check, should be managed by middleware through a predefined set of rules defined in light of the clinical governance. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  13. Energy Systems Fabrication Laboratory | Energy Systems Integration Facility

    Science.gov Websites

    Fabrication The fuel cell fabrication hub includes laboratory spaces with local exhaust and chemical fume hoods that support electrolysis and other chemical process research. Key Infrastructure Perchloric acid washdown hood, local exhaust, specialty gas manifolding, deionized water, chemical fume hoods, glassware

  14. Harmonization of good laboratory practice requirements and laboratory accreditation programs.

    PubMed

    Royal, P D

    1994-09-01

    Efforts to harmonize Good Laboratory Practice (GLP) requirements have been underway through the Organization for Economic Cooperation and Development (OECD) since 1981. In 1985, a GLP panel was established to facilitate the practical implementation of the OECD/GLP program. Through the OECD/GLP program, Memoranda of Understanding (MOU) agreements which foster requirements for reciprocal data and study acceptance and unified GLP standards have been developed among member countries. Three OECD Consensus Workshops and three inspectors training workshops have been held. In concert with these efforts, several OECD countries have developed GLP accreditation programs, managed by local health and environmental ministries. In addition, Canada and the United States are investigating Laboratory Accreditation programs for environmental monitoring assessment and GLP-regulated studies. In the European Community (EC), the need for quality standards specifying requirements for production and international trade has promoted International Standards Organization (ISO) certification for certain products. ISO-9000 standards identify requirements for certification of quality systems. These certification programs may affect the trade and market of laboratories conducting GLP studies. Two goals identified by these efforts are common to both programs: first, harmonization and recognition of requirements, and second, confidence in the rigor of program components used to assess the integrity of data produced and study activities. This confidence can be promoted, in part, through laboratory inspection and screening processes. However, the question remains, will data produced by sanctioned laboratories be mutually accepted on an international basis?(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Gazing at the Hand: A Foucaultian View of the Teaching of Manipulative Skills to Introductory Chemistry Students in the United States and the Potential for Transforming Laboratory Instruction

    ERIC Educational Resources Information Center

    Demeo, Stephen

    2005-01-01

    Many studies of chemistry have described the rise of the academic chemical laboratory and laboratory skills in the United States as a result of famous men, important discoveries, and international influences. What is lacking is a perspective of the manifestations of the balances of power and knowledge between teacher and student. A Foucaultian…

  16. Dental Laboratory Career Ladder AFS 982X0.

    DTIC Science & Technology

    1982-09-01

    7ADA120 102 AIR FORCE OCCUPATIONAL MEASUREMENT CENTER RANDOLPH AFB TX F/6 Ri9 DENTAL LABORATORY CAREER LADDER AFS 982XO.(U) UNCLASSIFIED NLEEEili E...Eli E~lllllllllEEE EEEEEIIIEEEEEE EIEEEEIIEEEEEE IIIIIIIIIIIIIIlLZ UNITED STATES AIR FORCE 0! DENTAL LABORATORY CAREER LADDER DTlC AFS 982X0 ELEr.L_...LADDER STRUCTURE GROUPS ----------------------------------- 57 APPENDIX B - JOB DESCRIPTIONS FOR BASE AND AREA DENTAL LABORATORY PERSONNEL

  17. KEY COMPARISON: Final report of the SIM 60Co absorbed-dose-to-water comparison SIM.RI(I)-K4

    NASA Astrophysics Data System (ADS)

    Ross, C. K.; Shortt, K. R.; Saravi, M.; Meghzifene, A.; Tovar, V. M.; Barbosa, R. A.; da Silva, C. N.; Carrizales, L.; Seltzer, S. M.

    2008-01-01

    Transfer chambers were used to compare the standards for 60Co absorbed dose to water maintained by seven laboratories. Six of the laboratories were members of the Sistema Interamericano de Metrología (SIM) regional metrology organization while the seventh was the International Atomic Energy Agency (IAEA) laboratory in Vienna. The National Research Council (NRC) acted as the pilot laboratory for the comparison. Because of the participation of laboratories holding primary standards, the comparison results could be linked to the key comparison reference value maintained by the Bureau International des Poids et Mesures (BIPM). The results for all laboratories were within the expanded uncertainty (two standard deviations) of the reference value. The estimated relative standard uncertainty on the comparison between any pair of laboratories ranged from 0.6% to 1.4%. The largest discrepancy between any two laboratories was 1.3%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI Section I, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  18. The Influence of Laboratory Safety on Capital Planning.

    ERIC Educational Resources Information Center

    Francis, Robert A.

    1980-01-01

    Discusses state and federal legislation concerning the handling of dangerous materials and its impact on the design of college and university buildings. Lists federal legislation affecting laboratory safety, the objectives of each act, and the influence of each act on laboratory safety. (IRT)

  19. Visualizing geographic and temporal trends in rotavirus activity in the United States, 1991 to 1996. National Respiratory and Enteric Virus Surveillance System Collaborating Laboratories.

    PubMed

    Török, T J; Kilgore, P E; Clarke, M J; Holman, R C; Bresee, J S; Glass, R I

    1997-10-01

    Rotavirus is the leading cause of severe pediatric gastroenteritis worldwide. A vaccine may soon be licensed for use in the United States to prevent this disease. To characterize US geographic and temporal trends in rotavirus activity, we made contour maps showing the timing of peak rotavirus activity. From July, 1991, through June, 1996, 79 laboratories participating in the National Respiratory and Enteric Virus Surveillance System reported on a weekly basis the number of stool specimens that tested positive for rotavirus. The peak weeks in rotavirus detections from each laboratory were mapped using kriging, a modeling technique originally developed for geostatistics. During the 5-year period 118,716 fecal specimens were examined, of which 27,616 (23%) were positive for rotavirus. Timing of rotavirus activity varied by geographic location in a characteristic pattern in which peak activity occurred first in the Southwest from October through December and last in the Northeast in April or May. The Northwest exhibited considerable year-to-year variability (range, December to May) in the timing of peak activity, whereas the temporal pattern in the remainder of the contiguous 48 states was relatively constant. Kriging is a useful method for visualizing geographic and temporal trends in rotavirus activity in the United States. This analysis confirmed trends reported in previous years, and it also identified unexpected variability in the timing of peak rotavirus activity in the Northwest. The causes of the seasonal differences in rotavirus activity by region are unknown. Tracking of laboratory detections of rotavirus may provide an effective surveillance tool to assess the impact of a rotavirus vaccination campaign in the United States.

  20. Key Elements of a State Master Plan in Higher Education

    ERIC Educational Resources Information Center

    McHenry, Kristen L.; Flora, Bethany H.

    2017-01-01

    A master plan in higher education is developed to address the academic and workforce needs of a particular state. The master plan helps serve as the roadmap for implementation of proposed strategies to reach state goals in education and degree attainment. In Tennessee, Drive to 55 is a state-wide effort to increase the number of Tennesseans with a…

  1. Anatomic pathology laboratory information systems: a review.

    PubMed

    Park, Seung Lyung; Pantanowitz, Liron; Sharma, Gaurav; Parwani, Anil Vasdev

    2012-03-01

    The modern anatomic pathology laboratory depends on a reliable information infrastructure to register specimens, record gross and microscopic findings, regulate laboratory workflow, formulate and sign out report(s), disseminate them to the intended recipients across the whole health system, and support quality assurance measures. This infrastructure is provided by the Anatomical Pathology Laboratory Information Systems (APLIS), which have evolved over decades and now are beginning to support evolving technologies like asset tracking and digital imaging. As digital pathology transitions from "the way of the future" to "the way of the present," the APLIS continues to be one of the key effective enablers of the scope and practice of pathology. In this review, we discuss the evolution, necessary components, architecture and functionality of the APLIS that are crucial to today's practicing pathologist and address the demands of emerging trends on the future APLIS.

  2. Automated Generation of Tabular Equations of State with Uncertainty Information

    NASA Astrophysics Data System (ADS)

    Carpenter, John H.; Robinson, Allen C.; Debusschere, Bert J.; Mattsson, Ann E.

    2015-06-01

    As computational science pushes toward higher fidelity prediction, understanding the uncertainty associated with closure models, such as the equation of state (EOS), has become a key focus. Traditional EOS development often involves a fair amount of art, where expert modelers may appear as magicians, providing what is felt to be the closest possible representation of the truth. Automation of the development process gives a means by which one may demystify the art of EOS, while simultaneously obtaining uncertainty information in a manner that is both quantifiable and reproducible. We describe our progress on the implementation of such a system to provide tabular EOS tables with uncertainty information to hydrocodes. Key challenges include encoding the artistic expert opinion into an algorithmic form and preserving the analytic models and uncertainty information in a manner that is both accurate and computationally efficient. Results are demonstrated on a multi-phase aluminum model. *Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  3. Laboratory Animal Technician | Center for Cancer Research

    Cancer.gov

    PROGRAM DESCRIPTION The Laboratory Animal Sciences Program (LASP) provides exceptional quality animal care and technical support services for animal research performed at the National Cancer Institute at the Frederick National Laboratory for Cancer Research. LASP executes this mission by providing a broad spectrum of state-of-the-art technologies and services that are focused

  4. First Year Chemistry Laboratory Courses for Distance Learners: Development and Transfer Credit Acceptance

    ERIC Educational Resources Information Center

    Brewer, Sharon E.; Cinel, Bruno; Harrison, Michelle; Mohr, Christina L.

    2013-01-01

    In delivering chemistry courses by distance, a key challenge is to offer the learner an authentic and meaningful laboratory experience that still provides the rigour required to continue on in science. To satisfy this need, two distance general chemistry laboratory courses appropriate for Bachelor of Science (B.Sc.) students, including chemistry…

  5. Using Interorganizational Partnerships to Strengthen Public Health Laboratory Systems

    PubMed Central

    Kimsey, Paul; Buehring, Gertrude

    2013-01-01

    Due to the current economic environment, many local and state health departments are faced with budget reductions. Health department administrators and public health laboratory (PHL) directors need to assess strategies to ensure that their PHLs can provide the same level of service with decreased funds. Exploratory case studies of interorganizational partnerships among local PHLs in California were conducted to determine the impact on local PHL testing services and capacity. Our findings suggest that interorganizational forms of cooperation among local PHLs can help bolster laboratory capacity by capturing economies of scale, leveraging scarce resources, and ensuring access to affordable, timely, and quality laboratory testing services. Interorganizational partnerships will help local and state public health departments continue to maintain a strong and robust laboratory system that supports their role in communicable disease surveillance. PMID:23997305

  6. Laboratory and outside the laboratory measurements of ginned and ot ginned cotton for fiber micronaire and maturity by portable Near Infrared (NIR) Instruments

    USDA-ARS?s Scientific Manuscript database

    Micronaire is a key cotton quality assessment property, impacting downstream fiber processing and dye consistency. A component of micronaire is fiber maturity (degree of secondary wall development). Historically, micronaire and maturity are measured in a laboratory under tight environmental condit...

  7. Development of a competency based training programme to support multidisciplinary working in a combined biochemistry/haematology laboratory

    PubMed Central

    Woods, R; Longmire, W; Galloway, M; Smellie, W

    2000-01-01

    The aim of this study was to develop a competency based training programme to support multidisciplinary working in a combined biochemistry and haematology laboratory. The training programme was developed to document that staff were trained in the full range of laboratory tests that they were expected to perform. This programme subsequently formed the basis for the annual performance review of all staff. All staff successfully completed the first phase of the programme. This allowed laboratory staff to work unsupervised at night as part of a partial shift system. All staff are now working towards achieving a level of competence equivalent to the training level required for state registration by the Council for Professions Supplementary to Medicine. External evaluation of the training programme has included accreditation by the Council for Professions Supplementary to Medicine and reinspection by Clinical Pathology Accreditation (UK) Ltd. The development of a competency based training system has facilitated the introduction of multidisciplinary working in the laboratory. In addition, it enables the documentation of all staff to ensure that they are fully trained and are keeping up to date, because the continuing professional development programme in use in our laboratory has been linked to this training scheme. This approach to documentation of training facilitated a recent reinspection by Clinical Pathology Accreditation (UK) Ltd. Key Words: Keyword: multidisciplinary working • competency based training PMID:10889827

  8. Visiting Scholars Program | Frederick National Laboratory for Cancer Research

    Cancer.gov

    The Visiting Scholars Program (VSP) provides a unique opportunity for scientists to collaborate with the Frederick National Laboratory for Cancer Research (FNLCR), the only federal national laboratory in the United States devoted exclusively to b

  9. Proteotyping of laboratory-scale biogas plants reveals multiple steady-states in community composition.

    PubMed

    Kohrs, F; Heyer, R; Bissinger, T; Kottler, R; Schallert, K; Püttker, S; Behne, A; Rapp, E; Benndorf, D; Reichl, U

    2017-08-01

    Complex microbial communities are the functional core of anaerobic digestion processes taking place in biogas plants (BGP). So far, however, a comprehensive characterization of the microbiomes involved in methane formation is technically challenging. As an alternative, enriched communities from laboratory-scale experiments can be investigated that have a reduced number of organisms and are easier to characterize by state of the art mass spectrometric-based (MS) metaproteomic workflows. Six parallel laboratory digesters were inoculated with sludge from a full-scale BGP to study the development of enriched microbial communities under defined conditions. During the first three month of cultivation, all reactors (R1-R6) were functionally comparable regarding biogas productions (375-625 NL L reactor volume -1 d -1 ), methane yields (50-60%), pH values (7.1-7.3), and volatile fatty acids (VFA, <5 mM). Nevertheless, a clear impact of the temperature (R3, R4) and ammonia (R5, R6) shifts was observed for the respective reactors. In both reactors operated under thermophilic regime, acetic and propionic acid (10-20 mM) began to accumulate. While R4 recovered quickly from acidification, the levels of VFA remained to be high in R3 resulting in low pH values of 6.5-6.9. The digesters R5 and R6 operated under the high ammonia regime (>1 gNH 3 L -1 ) showed an increase to pH 7.5-8.0, accumulation of acetate (>10 mM), and decreasing biogas production (<125 NL L reactor volume -1 d -1 ). Tandem MS (MS/MS)-based proteotyping allowed the identification of taxonomic abundances and biological processes. Although all reactors showed similar performances, proteotyping and terminal restriction fragment length polymorphisms (T-RFLP) fingerprinting revealed significant differences in the composition of individual microbial communities, indicating multiple steady-states. Furthermore, cellulolytic enzymes and cellulosomal proteins of Clostridium thermocellum were identified to be specific

  10. Consensus building for interlaboratory studies, key comparisons, and meta-analysis

    NASA Astrophysics Data System (ADS)

    Koepke, Amanda; Lafarge, Thomas; Possolo, Antonio; Toman, Blaza

    2017-06-01

    Interlaboratory studies in measurement science, including key comparisons, and meta-analyses in several fields, including medicine, serve to intercompare measurement results obtained independently, and typically produce a consensus value for the common measurand that blends the values measured by the participants. Since interlaboratory studies and meta-analyses reveal and quantify differences between measured values, regardless of the underlying causes for such differences, they also provide so-called ‘top-down’ evaluations of measurement uncertainty. Measured values are often substantially over-dispersed by comparison with their individual, stated uncertainties, thus suggesting the existence of yet unrecognized sources of uncertainty (dark uncertainty). We contrast two different approaches to take dark uncertainty into account both in the computation of consensus values and in the evaluation of the associated uncertainty, which have traditionally been preferred by different scientific communities. One inflates the stated uncertainties by a multiplicative factor. The other adds laboratory-specific ‘effects’ to the value of the measurand. After distinguishing what we call recipe-based and model-based approaches to data reductions in interlaboratory studies, we state six guiding principles that should inform such reductions. These principles favor model-based approaches that expose and facilitate the critical assessment of validating assumptions, and give preeminence to substantive criteria to determine which measurement results to include, and which to exclude, as opposed to purely statistical considerations, and also how to weigh them. Following an overview of maximum likelihood methods, three general purpose procedures for data reduction are described in detail, including explanations of how the consensus value and degrees of equivalence are computed, and the associated uncertainty evaluated: the DerSimonian-Laird procedure; a hierarchical Bayesian

  11. Management of laboratory data and information exchange in the electronic health record.

    PubMed

    Wilkerson, Myra L; Henricks, Walter H; Castellani, William J; Whitsitt, Mark S; Sinard, John H

    2015-03-01

    In the era of the electronic health record, the success of laboratories and pathologists will depend on effective presentation and management of laboratory information, including test orders and results, and effective exchange of data between the laboratory information system and the electronic health record. In this third paper of a series that explores empowerment of pathology in the era of the electronic health record, we review key elements of managing laboratory information within the electronic health record and examine functional issues pertinent to pathologists and laboratories in the exchange of laboratory information between electronic health records and both anatomic and clinical pathology laboratory information systems. Issues with electronic order-entry and results-reporting interfaces are described, and considerations for setting up these interfaces are detailed in tables. The role of the laboratory medical director as mandated by the Clinical Laboratory Improvement Amendments of 1988 and the impacts of discordance between laboratory results and their display in the electronic health record are also discussed.

  12. Continuous high speed coherent one-way quantum key distribution.

    PubMed

    Stucki, Damien; Barreiro, Claudio; Fasel, Sylvain; Gautier, Jean-Daniel; Gay, Olivier; Gisin, Nicolas; Thew, Rob; Thoma, Yann; Trinkler, Patrick; Vannel, Fabien; Zbinden, Hugo

    2009-08-03

    Quantum key distribution (QKD) is the first commercial quantum technology operating at the level of single quanta and is a leading light for quantum-enabled photonic technologies. However, controlling these quantum optical systems in real world environments presents significant challenges. For the first time, we have brought together three key concepts for future QKD systems: a simple high-speed protocol; high performance detection; and integration both, at the component level and for standard fibre network connectivity. The QKD system is capable of continuous and autonomous operation, generating secret keys in real time. Laboratory and field tests were performed and comparisons made with robust InGaAs avalanche photodiodes and superconducting detectors. We report the first real world implementation of a fully functional QKD system over a 43 dB-loss (150 km) transmission line in the Swisscom fibre optic network where we obtained average real-time distribution rates over 3 hours of 2.5 bps.

  13. Laboratory investigation of hypercoagulability.

    PubMed

    Francis, J L

    1998-01-01

    For many years, the laboratory investigation of patients with thrombophilia has lagged behind that of patients with bleeding diathesis. Improved understanding of the mechanisms that control and regulate coagulation, and the resultant recognition of new defects, have greatly stimulated clinical laboratory interest in this area. Assays to detect resistance to activated protein C; deficiencies of antithrombin, protein C, and protein S; and the presence of antiphospholipid antibodies are widely available and should form part of the investigation of patients that present with idiopathic thrombosis. Such a work-up will likely provide an explanation for thrombosis in 40 to 60% of patients. Abnormalities of fibrinogen and fibrinolysis may explain still more, although such defects are currently considered rare. In addition, presently unrecognized defects almost certainly exist, and the identification of such individuals will undoubtedly improve our understanding of the hemostatic mechanism. Laboratory tests to define the hypercoagulable state are continually being developed. They include whole blood coagulation and platelet function tests and novel activation markers. However, acceptance of these approaches by clinical laboratories has been slow.

  14. Continuous-variable quantum authentication of physical unclonable keys

    NASA Astrophysics Data System (ADS)

    Nikolopoulos, Georgios M.; Diamanti, Eleni

    2017-04-01

    We propose a scheme for authentication of physical keys that are materialized by optical multiple-scattering media. The authentication relies on the optical response of the key when probed by randomly selected coherent states of light, and the use of standard wavefront-shaping techniques that direct the scattered photons coherently to a specific target mode at the output. The quadratures of the electromagnetic field of the scattered light at the target mode are analysed using a homodyne detection scheme, and the acceptance or rejection of the key is decided upon the outcomes of the measurements. The proposed scheme can be implemented with current technology and offers collision resistance and robustness against key cloning.

  15. Secondary School Chemistry Teacher's Current Use of Laboratory Activities and the Impact of Expense on Their Laboratory Choices

    ERIC Educational Resources Information Center

    Boesdorfer, Sarah B.; Livermore, Robin A.

    2018-01-01

    In the United States with the Next Generation Science Standards (NGSS)'s emphasis on learning science while doing science, laboratory activities in the secondary school chemistry continues to be an important component of a strong curriculum. Laboratory equipment and consumable materials create a unique expense which chemistry teachers and schools…

  16. Status of Undergraduate Pharmacology Laboratories in Colleges of Pharmacy in the United States

    ERIC Educational Resources Information Center

    Katz, Norman L.; And Others

    1978-01-01

    U.S. colleges of pharmacy were surveyed in 1976 to determine whether a trend exists in continuing, discontinuing, or restructuring laboratory time in pharmaceutical education. Data regarding core undergraduate pharmacology courses, undergraduate pharmacology laboratory status, and pharmacology faculty are presented. (LBH)

  17. Computer-Assisted Laboratory Stations.

    ERIC Educational Resources Information Center

    Snyder, William J., Hanyak, Michael E.

    1985-01-01

    Describes the advantages and features of computer-assisted laboratory stations for use in a chemical engineering program. Also describes a typical experiment at such a station: determining the response times of a solid state humidity sensor at various humidity conditions and developing an empirical model for the sensor. (JN)

  18. Benchmarking and the laboratory

    PubMed Central

    Galloway, M; Nadin, L

    2001-01-01

    This article describes how benchmarking can be used to assess laboratory performance. Two benchmarking schemes are reviewed, the Clinical Benchmarking Company's Pathology Report and the College of American Pathologists' Q-Probes scheme. The Clinical Benchmarking Company's Pathology Report is undertaken by staff based in the clinical management unit, Keele University with appropriate input from the professional organisations within pathology. Five annual reports have now been completed. Each report is a detailed analysis of 10 areas of laboratory performance. In this review, particular attention is focused on the areas of quality, productivity, variation in clinical practice, skill mix, and working hours. The Q-Probes scheme is part of the College of American Pathologists programme in studies of quality assurance. The Q-Probes scheme and its applicability to pathology in the UK is illustrated by reviewing two recent Q-Probe studies: routine outpatient test turnaround time and outpatient test order accuracy. The Q-Probes scheme is somewhat limited by the small number of UK laboratories that have participated. In conclusion, as a result of the government's policy in the UK, benchmarking is here to stay. Benchmarking schemes described in this article are one way in which pathologists can demonstrate that they are providing a cost effective and high quality service. Key Words: benchmarking • pathology PMID:11477112

  19. [Reversed clinicopathological conference (R-CPC)--interpreting laboratory data in the same way as physical findings].

    PubMed

    Sugano, Mitsutoshi; Shimada, Masashi; Moriyoshi, Miho; Kitagawa, Kiyoki; Nakashima, Hiromi; Wada, Hideo; Yanagihara, Katsunori; Fujisawa, Shinya; Yonekawa, Osamu; Honda, Takayuki

    2012-05-01

    Routine laboratory data are discussed by time series analysis in reversed clinicopathological conferences (R-CPC) at Shinshu University School of Medicine. We can identify fine changes in the laboratory data and the importance of negative data (without any changes) using time series analysis. Routine laboratory tests can be performed repeatedly and relatively cheaply, and time series analysis can be performed. The examination process of routine laboratory data in the R-CPC is almost the same as the process of taking physical findings. Firstly, general findings are checked and then the state of each organ is examined. Although routine laboratory data are cheap, we can obtain much more information about a patient's state than from physical examinations. In this R-CPC, several specialists in the various fields of laboratory medicine discussed the routine laboratory data of a patient, and we tried to understand the detailed state of the patient. R-CPC is an educational method to examine laboratory data and we, reconfirmed the usefulness of R-CPC to elucidate the clinical state of the patient.

  20. Fully device-independent quantum key distribution.

    PubMed

    Vazirani, Umesh; Vidick, Thomas

    2014-10-03

    Quantum cryptography promises levels of security that are impossible to replicate in a classical world. Can this security be guaranteed even when the quantum devices on which the protocol relies are untrusted? This central question dates back to the early 1990s when the challenge of achieving device-independent quantum key distribution was first formulated. We answer this challenge by rigorously proving the device-independent security of a slight variant of Ekert's original entanglement-based protocol against the most general (coherent) attacks. The resulting protocol is robust: While assuming only that the devices can be modeled by the laws of quantum mechanics and are spatially isolated from each other and from any adversary's laboratory, it achieves a linear key rate and tolerates a constant noise rate in the devices. In particular, the devices may have quantum memory and share arbitrary quantum correlations with the eavesdropper. The proof of security is based on a new quantitative understanding of the monogamous nature of quantum correlations in the context of a multiparty protocol.

  1. Fully Device-Independent Quantum Key Distribution

    NASA Astrophysics Data System (ADS)

    Vazirani, Umesh; Vidick, Thomas

    2014-10-01

    Quantum cryptography promises levels of security that are impossible to replicate in a classical world. Can this security be guaranteed even when the quantum devices on which the protocol relies are untrusted? This central question dates back to the early 1990s when the challenge of achieving device-independent quantum key distribution was first formulated. We answer this challenge by rigorously proving the device-independent security of a slight variant of Ekert's original entanglement-based protocol against the most general (coherent) attacks. The resulting protocol is robust: While assuming only that the devices can be modeled by the laws of quantum mechanics and are spatially isolated from each other and from any adversary's laboratory, it achieves a linear key rate and tolerates a constant noise rate in the devices. In particular, the devices may have quantum memory and share arbitrary quantum correlations with the eavesdropper. The proof of security is based on a new quantitative understanding of the monogamous nature of quantum correlations in the context of a multiparty protocol.

  2. Safety in the Chemical Laboratory. Epidemiology of Accidents in Academic Chemistry Laboratories, Part 2. Accident Intervention Study, Legal Aspects, and Observations.

    ERIC Educational Resources Information Center

    Hellmann, Margaret A.; And Others

    1986-01-01

    Reports on a chemistry laboratory accident intervention study conducted throughout the state of Colorado. Addresses the results of an initial survey of institutions of higher learning. Discusses some legal aspects concerning academic chemistry accidents. Provides some observations about academic chemistry laboratory accidents on the whole. (TW)

  3. External quality assessment of national public health laboratories in Africa, 2002–2009

    PubMed Central

    Perovic, Olga; Fensham, Vivian; McCarthy, Kerrigan; von Gottberg, Anne; de Gouveia, Linda; Poonsamy, Bhavani; Dini, Leigh; Rossouw, Jenny; Keddy, Karen; Alemu, Wondimagegnehu; Yahaya, Ali; Pierson, Antoine; Dolmazon, Virginie; Cognat, Sébastien; Ndihokubwayo, Jean Bosco

    2012-01-01

    Abstract Objective To describe findings from an external quality assessment programme involving laboratories in Africa that routinely investigate epidemic-prone diseases. Methods Beginning in 2002, the Regional Office for Africa of the World Health Organization (WHO) invited national public health laboratories and related facilities in Africa to participate in the programme. Three surveys comprising specimens and questionnaires associated with bacterial enteric diseases, bacterial meningitis, plague, tuberculosis and malaria were sent annually to test participants’ diagnostic proficiency. Identical surveys were sent to referee laboratories for quality control. Materials were prepared, packaged and shipped in accordance with standard protocols. Findings and reports were due within 30 days. Key methodological decisions and test results were categorized as acceptable or unacceptable on the basis of consensus feedback from referees, using established grading schemes. Findings Between 2002 and 2009, participation increased from 30 to 48 Member States of the WHO and from 39 to 78 laboratories. Each survey was returned by 64–93% of participants. Mean turnaround time was 25.9 days. For bacterial enteric diseases and meningitis components, bacterial identification was acceptable in 65% and 69% of challenges, respectively, but serotyping and antibiotic susceptibility testing and reporting were frequently unacceptable. Microscopy was acceptable for 73% of plague challenges. Tuberculosis microscopy was satisfactorily performed, with 87% of responses receiving acceptable scores. In the malaria component, 82% of responses received acceptable scores for species identification but only 51% of parasite quantitation scores were acceptable. Conclusion The external quality assessment programme consistently identified certain functional deficiencies requiring strengthening that were present in African public health microbiology laboratories. PMID:22461714

  4. Laboratory Information Management Systems for Forensic Laboratories: A White Paper for Directors and Decision Makers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anthony Hendrickson; Brian Mennecke; Kevin Scheibe

    2005-10-01

    Modern, forensics laboratories need Laboratory Information Management Systems (LIMS) implementations that allow the lab to track evidentiary items through their examination lifecycle and also serve all pertinent laboratory personnel. The research presented here presents LIMS core requirements as viewed by respondents serving in different forensic laboratory capacities as well as different forensic laboratory environments. A product-development methodology was employed to evaluate the relative value of the key features that constitute a LIMS, in order to develop a set of relative values for these features and the specifics of their implementation. In addition to the results of the product development analysis,more » this paper also provides an extensive review of LIMS and provides an overview of the preparation and planning process for the successful upgrade or implementation of a LIMS. Analysis of the data indicate that the relative value of LIMS components are viewed differently depending upon respondents' job roles (i.e., evidence technicians, scientists, and lab management), as well as by laboratory size. Specifically, the data show that: (1) Evidence technicians place the most value on chain of evidence capabilities and on chain of custody tracking; (2) Scientists generally place greatest value on report writing and generation, and on tracking daughter evidence that develops during their analyses; (3) Lab. Managers place the greatest value on chain of custody, daughter evidence, and not surprisingly, management reporting capabilities; and (4) Lab size affects LIMS preference in that, while all labs place daughter evidence tracking, chain of custody, and management and analyst report generation as their top three priorities, the order of this prioritization is size dependent.« less

  5. Remote sensing of smokestack emissions using a mobile environmental laboratory

    NASA Astrophysics Data System (ADS)

    Mosebach, Herbert W.; Eisenmann, T.; Schulz-Spahr, Y.; Neureither, I.; Bittner, Hermann; Rippel, Harald; Schaefer, Klaus; Wehner, Dieter; Haus, Rainer

    1993-03-01

    A mobile environmental laboratory has been developed. This laboratory consists of a van which is equipped with different environmental sensors. The FT-IR system K300 by Kayser- Threde is the key instrument. With this K300 the van can be used for remote measurements of the gaseous emissions from smoke stacks. In addition the laboratory is equipped with standard ambient air analyzers as well as meteorological sensors. A large battery system ensures current source free operation the whole day. Reloading of the batteries takes only one night. remote measurements with this van were carried out at different power plants. Several pollutants could be analyzed. First results are presented.

  6. Survey of 2014 Behavioral Management Programs for Laboratory Primates in the United States

    PubMed Central

    BAKER, KATE C.

    2016-01-01

    The behavioral management of laboratory nonhuman primates in the United States has not been thoroughly characterized since 2003. This article presents the results of a survey behavioral management programs at 27 facilities and covering a total of 59,636 primates, 27,916 housed in indoor cages and 31,720 in group enclosures. The survey included questions regarding program structure, implementation, and methodology associated with social housing, positive reinforcement training, positive human interaction, exercise enclosures, and several categories of inanimate enrichment. The vast majority of laboratory primates are housed socially (83%). Since 2003, the proportion of indoor-housed primates reported to be housed singly has fallen considerably, from 59% to 35% in the facilities surveyed. The use of social housing remains significantly constrained by: 1) research protocol requirements, highlighting the value of closely involved IACUCs for harmonizing research and behavioral management; and 2) the unavailability of compatible social partners, underscoring the necessity of objective analysis of the methods used to foster and maintain compatibility. Positive reinforcement training appears to have expanded and is now used at all facilities responding to the survey. The use of enrichment devices has also increased in the participating facilities. For most behavioral management techniques, concerns over the possibility of negative consequences to animals are expressed most frequently for social housing and destructible enrichment, while skepticism regarding efficacy is limited almost exclusively to sensory enrichment. Behavioral management program staffing has expanded over time in the facilities surveyed, due not only to increased numbers of dedicated behavioral management technicians but also to greater involvement of animal care technicians, suggesting an increase in the integration of behavioral care into animal husbandry. Broad awareness of common practice may assist

  7. Security Standards and Best Practice Considerations for Quantum Key Distribution (QKD)

    DTIC Science & Technology

    2012-03-01

    SECURITY STANDARDS AND BEST PRACTICE CONSIDERATIONS FOR QUANTUM KEY DISTRIBUTION (QKD) THESIS...protection in the United States. AFIT/GSE/ENV/12-M05 SECURITY STANDARDS AND BEST PRACTICE CONSIDERATIONS FOR QUANTUM KEY DISTRIBUTION (QKD...FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED. AFIT/GSE/ENV/12-M05 SECURITY STANDARDS AND BEST PRACTICE CONSIDERATIONS FOR QUANTUM KEY

  8. Proceedings of the NASA Laboratory Astrophysics Workshop

    NASA Technical Reports Server (NTRS)

    Weck, Phillippe F. (Editor); Kwong, Victor H. S. (Editor); Salama, Farid (Editor)

    2006-01-01

    This report is a collection of papers presented at the 2006 NASA Workshop on Laboratory Astrophysics held in the University of Nevada, Las Vegas (UNLV) from February 14 to 16, 2006. This workshop brings together producers and users of laboratory astrophysics data so that they can understand each other's needs and limitations in the context of the needs for NASA's missions. The last NASA-sponsored workshop was held in 2002 at Ames Research Center. Recent related meetings include the Topical Session at the AAS meeting and the European workshop at Pillnitz, Germany, both of which were held in June 2005. The former showcased the importance of laboratory astrophysics to the community at large, while the European workshop highlighted a multi-laboratory approach to providing the needed data. The 2006 NASA Workshop on Laboratory Astrophysics, sponsored by the NASA Astrophysics Division, focused on the current status of the field and its relevance to NASA. This workshop attracted 105 participants and 82 papers of which 19 were invited. A White Paper identifying the key issues in laboratory astrophysics during the break-out sessions was prepared by the Scientific Organizing Committee, and has been forwarded to the Universe Working Group (UWG) at NASA Headquarters. This White Paper, which represented the collective inputs and opinions from experts and stakeholders in the field of astrophysics, should serve as the working document for the future development of NASA's R&A program in laboratory astrophysics.

  9. [Accreditation of clinical laboratories based on ISO standards].

    PubMed

    Kawai, Tadashi

    2004-11-01

    International Organization for Standardization (ISO) have published two international standards (IS) to be used for accreditation of clinical laboratories; ISO/IEC 17025:1999 and ISO 15189:2003. Any laboratory accreditation body must satisfy the requirements stated in ISO/IEC Guide 58. In order to maintain the quality of the laboratory accreditation bodies worldwide, the International Laboratory Accreditation Cooperation (ILAC) has established the mutual recognition arrangement (MRA). In Japan, the International Accreditation Japan (IAJapan) and the Japan Accreditation Board for Conformity Assessment (JAB) are the members of the ILAC/MRA group. In 2003, the Japanese Committee for Clinical Laboratory Standards (JCCLS) and the JAB have established the Development Committee of Clinical Laboratory Accreditation Program (CLAP), in order to establish the CLAP, probably starting in 2005.

  10. Energy Systems Integration Laboratory | Energy Systems Integration Facility

    Science.gov Websites

    systems test hub includes a Class 1, Division 2 space for performing tests of high-pressure hydrogen Laboratory offers the following capabilities. High-Pressure Hydrogen Systems The high-pressure hydrogen infrastructure. Key Infrastructure Robotic arm; high-pressure hydrogen; natural gas supply; standalone SCADA

  11. Air Force Phillips Laboratory Battery Program overview

    NASA Technical Reports Server (NTRS)

    House, Shaun

    1992-01-01

    Battery development and testing efforts at Phillips Laboratory fall into three main categories: nickel hydrogen, sodium sulfur, and solid state batteries. Nickel hydrogen work is broken down into a Low Earth Orbit (LEO) Life Test Program, a LEO Pulse Test Program, and a Hydrogen Embrittlement Investigation. Sodium sulfur work is broken down into a Geosynchronous Earth Orbit (GEO) Battery Flight Test and a Hot Launch Evaluation. Solid state polymer battery work consists of a GEO Battery Development Program, a Pulse Power Battery Small Business Innovation Research (SBIR), and an in-house evaluation of current generation laboratory cells. An overview of the program is presented.

  12. Laboratory identification of arthropod ectoparasites.

    PubMed

    Mathison, Blaine A; Pritt, Bobbi S

    2014-01-01

    The collection, handling, identification, and reporting of ectoparasitic arthropods in clinical and reference diagnostic laboratories are discussed in this review. Included are data on ticks, mites, lice, fleas, myiasis-causing flies, and bed bugs. The public health importance of these organisms is briefly discussed. The focus is on the morphological identification and proper handling and reporting of cases involving arthropod ectoparasites, particularly those encountered in the United States. Other arthropods and other organisms not of public health concern, but routinely submitted to laboratories for identification, are also briefly discussed.

  13. Laboratory Identification of Arthropod Ectoparasites

    PubMed Central

    Pritt, Bobbi S.

    2014-01-01

    SUMMARY The collection, handling, identification, and reporting of ectoparasitic arthropods in clinical and reference diagnostic laboratories are discussed in this review. Included are data on ticks, mites, lice, fleas, myiasis-causing flies, and bed bugs. The public health importance of these organisms is briefly discussed. The focus is on the morphological identification and proper handling and reporting of cases involving arthropod ectoparasites, particularly those encountered in the United States. Other arthropods and other organisms not of public health concern, but routinely submitted to laboratories for identification, are also briefly discussed. PMID:24396136

  14. Science Laboratory Environment and Academic Performance

    NASA Astrophysics Data System (ADS)

    Aladejana, Francisca; Aderibigbe, Oluyemisi

    2007-12-01

    The study determined how students assess the various components of their science laboratory environment. It also identified how the laboratory environment affects students' learning outcomes. The modified ex-post facto design was used. A sample of 328 randomly selected students was taken from a population of all Senior Secondary School chemistry students in a state in Nigeria. The research instrument, Science Laboratory Environment Inventory (SLEI) designed and validated by Fraser et al. (Sci Educ 77:1-24, 1993) was administered on the selected students. Data analysis was done using descriptive statistics and Product Moment Correlation. Findings revealed that students could assess the five components (Student cohesiveness, Open-endedness, Integration, Rule clarity, and Material Environment) of the laboratory environment. Student cohesiveness has the highest assessment while material environment has the least. The results also showed that the five components of the science laboratory environment are positively correlated with students' academic performance. The findings are discussed with a view to improving the quality of the laboratory environment, subsequent academic performance in science and ultimately the enrolment and retaining of learners in science.

  15. State Policy Is Key to Building Strong Leaders

    ERIC Educational Resources Information Center

    von Frank, Valerie

    2010-01-01

    Collective, comprehensive and cohesive are the words Gene Wilhoit uses to talk about education reform that involves multiple levels of the education system--states, districts, and schools. Today it is widely accepted that education leadership is crucial to improving student performance, and Wilhoit, executive director of the Council of Chief State…

  16. Leveraging the real value of laboratory medicine with the value proposition.

    PubMed

    Price, Christopher P; John, Andrew St; Christenson, Robert; Scharnhorst, Volker; Oellerich, Michael; Jones, Patricia; Morris, Howard A

    2016-11-01

    Improving quality and patient safety, containing costs and delivering value-for-money are the key drivers of change in the delivery of healthcare and have stimulated a shift from an activity-based service to a service based on patient-outcomes. The delivery of an outcomes-based healthcare agenda requires that the real value of laboratory medicine to all stakeholders be understood, effectively defined and communicated. The value proposition of any product or service is the link between the provider and the needs of the customer describing the utility of the product or service in terms of benefit to the customer. The framework of a value proposition for laboratory medicine provides the core business case that drives key activities in the evolution and maintenance of high quality healthcare from research through to adoption and quality improvement in an established service. The framework of a value proposition for laboratory medicine is described. The content is endorsed by IFCC and WASPaLM. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Science and Technology: The Making of the Air Force Research Laboratory

    DTIC Science & Technology

    2000-01-01

    AFRL . . . . . . . . . . . 187 11 Air Force Research Laboratory : Before and After...United States Air Force during my tenure as chief of staff—the crea - tion of the Air Force Research Laboratory ( AFRL ). As the “high technology” service...consolidate four existing laboratories into one Air Force Research Laboratory ( AFRL ) designed to lead to a more efficient and streamlined

  18. Naval stores research at the Forest Products Laboratory, past and present

    Treesearch

    Duane F. Zinkel

    1987-01-01

    As many of you may not be familiar with Forest Products Laboratory, allow me to introduce it to you. The Forest Products Laboratory is a Federal government laboratory of the United States Department of Agriculture and, more specifically, of the Forest Service. The Laboratory was built in Madison, Wisconsin in close cooperation with the University of Wisconsin to serve...

  19. An Exploratory Study of Objective Attainment in the Divergent Physics Laboratory.

    ERIC Educational Resources Information Center

    Lerch, Robert Donald

    Students enrolled in the introductory physics laboratory at New Mexico State University participated in this study. A stated set of objectives, developed by Dr. John M. Fowler of the Commission on College Physics, was used in the laboratory. This study attempted to measure student achievement based on the use of these objectives as opposed to the…

  20. Deriving Equations of State for Specific Lakes and Inland Seas from Laboratory Measurements

    NASA Astrophysics Data System (ADS)

    Andrulionis, Natalia; Zavialov, Ivan; Zavialov, Peter; Osadchiev, Alexander; Kolokolova, Alexandra; Alukaeva, Alevtina; Izhitskiy, Alexander; Izhitskaya, Elena

    2017-04-01

    The equation of state is the dependence of water density on temperature, salinity, and pressure. It is important in many respects, in particular, for numerical modeling of marine systems. The widely used UNESCO equation of state, as well as the more recent and general TEOS-10 equation, are intended for the ocean waters. Hence, they are confined to salinities below 40 ‰ and, even more restrictively, valid only for ionic salt composition characteristic for the ocean. Both conditions do not hold for many lakes. Moreover, significant deviations of the ionic composition from the oceanic one have been documented for coastal zones, especially those exposed to river discharges. Therefore, the objective of this study was to find equations of state for areas or water bodies with non-oceanic ionic salt composition. In order to obtain the required equations, we analyzed water samples obtained in expeditions of 2014-2016 from the Black Sea, the Aral Sea, Lake Issyk-Kul and Caspian Sea. The filtered samples were submitted to high accuracy (up to 0.00001 g/cm3) density measurements in laboratory using the Anton Paar DMA 5000M in the temperature range from 1 to 29°C. The absolute salinity values of the initial samples were obtained through the dry residue method. Further, we diluted the samples by purified deionized water to produce different salinities. To control the accuracy of the dilution process, we used a reference sample of standard IAPSO-certified seawater at 35‰. The density versus salinity and temperature data obtained thereby were then approximated by a best fitting 2-order polynomial surface using the least squares method. This procedure yielded the approximate empirical equations of state for the selected marine areas (the Russian Black Sea shelf) and inland water bodies (the Aral Sea, the Lake Issyk-Kul, the Caspian Sea). The newly derived equations - even the one for the Black Sea shelf - are different from the oceanic equation significantly within the

  1. Regional Educational Laboratory Electronic Network Phase 2 System

    NASA Technical Reports Server (NTRS)

    Cradler, John

    1995-01-01

    The Far West Laboratory in collaboration with the other regional educational laboratories is establishing a regionally coordinated telecommunication network to electronically interconnect each of the ten regional laboratories with educators and education stakeholders from the school to the state level. For the national distributed information database, each lab is working with mid-level networks to establish a common interface for networking throughout the country and include topics of importance to education reform as assessment and technology planning.

  2. The future of the national laboratories

    PubMed Central

    Cohen, Linda R.; Noll, Roger G.

    1996-01-01

    The end of the Cold War has called into question the activities of the national laboratories and, more generally, the level of support now given to federal intramural research in the United States. This paper seeks to analyze the potential role of the laboratories, with particular attention to the possibility, on the one hand, of integrating private technology development into the laboratory’s menu of activities and, on the other hand, of outsourcing traditional mission activities. We review the economic efficiency arguments for intramural research and the political conditions that are likely to constrain the activities of the laboratories, and analyze the early history of programs intended to promote new technology via cooperative agreements between the laboratories and private industry. Our analysis suggests that the laboratories are likely to shrink considerably in size, and that the federal government faces a significant problem in deciding how to organize a downsizing of the federal research establishment. PMID:8917479

  3. Engines for experiment: laboratory revolution and industrial labor in the nineteenth-century city.

    PubMed

    Dierig, Sven

    2003-01-01

    This article brings together what until now have been separate fields of nineteenth-century history: the development of experimental physiology, the growth of mechanized industry, and the city, where their threads intertwined. The main argument is that the laboratory in the city employed the same technological and organizational approaches to modernize that the city used to industrialize. To bring the adoption of technology into focus, the article discusses laboratory research as it developed after the introduction of small-scale power engines. With its machines, the industrialized city provided not only the key metaphor of the nineteenth-century life sciences but also a key technology that shifted experimental practices in animal research from a kind of preindustrial craft to a more mechanized production of knowledge. With its "factory-laboratories," the late-nineteenth-century city became the birthplace for the first living, data-producing hybird---part animal and part machine.

  4. Myoglobin Structure and Function: A Multiweek Biochemistry Laboratory Project

    ERIC Educational Resources Information Center

    Silverstein, Todd P.; Kirk, Sarah R.; Meyer, Scott C.; Holman, Karen L. McFarlane

    2015-01-01

    We have developed a multiweek laboratory project in which students isolate myoglobin and characterize its structure, function, and redox state. The important laboratory techniques covered in this project include size-exclusion chromatography, electrophoresis, spectrophotometric titration, and FTIR spectroscopy. Regarding protein structure,…

  5. Multi-hop teleportation based on W state and EPR pairs

    NASA Astrophysics Data System (ADS)

    Hai-Tao, Zhan; Xu-Tao, Yu; Pei-Ying, Xiong; Zai-Chen, Zhang

    2016-05-01

    Multi-hop teleportation has significant value due to long-distance delivery of quantum information. Many studies about multi-hop teleportation are based on Bell pairs, partially entangled pairs or W state. The possibility of multi-hop teleportation constituted by partially entangled pairs relates to the number of nodes. The possibility of multi-hop teleportation constituted by double W states is after n-hop teleportation. In this paper, a multi-hop teleportation scheme based on W state and EPR pairs is presented and proved. The successful possibility of quantum information transmitted hop by hop through intermediate nodes is deduced. The possibility of successful transmission is after n-hop teleportation. Project supported by the National Natural Science Foundation of China (Grant No. 61571105), the Prospective Future Network Project of Jiangsu Province, China (Grant No. BY2013095-1-18), and the Independent Project of State Key Laboratory of Millimeter Waves, China (Grant No. Z201504).

  6. Laboratory-associated infections and biosafety.

    PubMed Central

    Sewell, D L

    1995-01-01

    An estimated 500,000 laboratory workers in the United States are at risk of exposure to infectious agents that cause disease ranging from inapparent to life-threatening infections, but the precise risk to a given worker unknown. The emergence of human immunodeficiency virus and hantavirus, the continuing problem of hepatitis B virus, and the reemergence of Mycobacterium tuberculosis have renewed interest in biosafety for the employees of laboratories and health care facilities. This review examines the history, the causes, and the methods for prevention of laboratory-associated infections. The initial step in a biosafety program is the assessment of risk to the employee. Risk assessment guidelines include the pathogenicity of the infectious agent, the method of transmission, worker-related risk factors, the source and route of infection, and the design of the laboratory facility. Strategies for the prevention and management of laboratory-associated infections are based on the containment of the infectious agent by physical separation from the laboratory worker and the environment, employee education about the occupational risks, and availability of an employee health program. Adherence to the biosafety guidelines mandated or proposed by various governmental and accrediting agencies reduces the risk of an occupational exposure to infectious agents handled in the workplace. PMID:7553572

  7. Photoproduction of hidden-charm states in the reaction near threshold

    NASA Astrophysics Data System (ADS)

    Huang, Yin; Xie, Ju-Jun; He, Jun; Chen, Xurong; Zhang, Hong-Fei

    2016-12-01

    We report on a theoretical study of the hidden charm states in the reaction near threshold within an effective Lagrangian approach. In addition to the contributions from the s-channel nucleon pole, the t-channel D0 exchange, the u-channel exchange and the contact term, we study the contributions from the states with spin-parity JP = 1/2- and 3/2-. The total and differential cross sections of the reaction are predicted. It is found that the contributions of these states give clear peak structures in the total cross sections. Thus, this reaction is another new platform to study the hidden-charm states. It is expected that our model calculation may be tested by future experiments. Supported by Major State Basic Research Development Program in China (2014CB845400), National Natural Science Foundation of China (11475227, 11275235, 11035006) and Chinese Academy of Sciences (Knowledge Innovation Project (KJCX2-EW-N01), Youth Innovation Promotion Association CAS (2016367), Open Project Program of State Key Laboratory of Theoretical Physics, Institute of Theoretical Physics, Chinese Academy of Sciences, China (Y5KF151CJ1)

  8. Continuous-variable quantum key distribution protocols over noisy channels.

    PubMed

    García-Patrón, Raúl; Cerf, Nicolas J

    2009-04-03

    A continuous-variable quantum key distribution protocol based on squeezed states and heterodyne detection is introduced and shown to attain higher secret key rates over a noisy line than any other one-way Gaussian protocol. This increased resistance to channel noise can be understood as resulting from purposely adding noise to the signal that is converted into the secret key. This notion of noise-enhanced tolerance to noise also provides a better physical insight into the poorly understood discrepancies between the previously defined families of Gaussian protocols.

  9. Quantum key distribution with an unknown and untrusted source

    NASA Astrophysics Data System (ADS)

    Zhao, Yi; Qi, Bing; Lo, Hoi-Kwong

    2008-05-01

    The security of a standard bidirectional “plug-and-play” quantum key distribution (QKD) system has been an open question for a long time. This is mainly because its source is equivalently controlled by an eavesdropper, which means the source is unknown and untrusted. Qualitative discussion on this subject has been made previously. In this paper, we solve this question directly by presenting the quantitative security analysis on a general class of QKD protocols whose sources are unknown and untrusted. The securities of standard Bennett-Brassard 1984 protocol, weak+vacuum decoy state protocol, and one-decoy state protocol, with unknown and untrusted sources are rigorously proved. We derive rigorous lower bounds to the secure key generation rates of the above three protocols. Our numerical simulation results show that QKD with an untrusted source gives a key generation rate that is close to that with a trusted source.

  10. AFRL Solid Propellant Laboratory Explosive Siting and Renovation Lessons Learned

    DTIC Science & Technology

    2010-05-19

    AFRL Solid Propellant Laboratory Explosive Siting and Renovation Lessons Learned Daniel F. Schwartz Air Force Research Laboratory ...9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) Air Force Research Laboratory (AFMC) AFRL /RZS...provide the United States Air Force with advanced rocket propulsion technologies, the Air Force Research

  11. Strategic establishment of an International Pharmacology Specialty Laboratory in a resource-limited setting.

    PubMed

    Mtisi, Takudzwa J; Maponga, Charles; Monera-Penduka, Tsitsi G; Mudzviti, Tinashe; Chagwena, Dexter; Makita-Chingombe, Faithful; DiFranchesco, Robin; Morse, Gene D

    2018-01-01

    A growing number of drug development studies that include pharmacokinetic evaluations are conducted in regions lacking a specialised pharmacology laboratory. This necessitated the development of an International Pharmacology Specialty Laboratory (IPSL) in Zimbabwe. The aim of this article is to describe the development of an IPSL in Zimbabwe. The IPSL was developed collaboratively by the University of Zimbabwe and the University at Buffalo Center for Integrated Global Biomedical Sciences. Key stages included infrastructure development, establishment of quality management systems and collaborative mentorship in clinical pharmacology study design and chromatographic assay development and validation. Two high performance liquid chromatography instruments were donated by an instrument manufacturer and a contract research organisation. Laboratory space was acquired through association with the Zimbabwe national drug regulatory authority. Operational policies, standard operating procedures and a document control system were established. Scientists and technicians were trained in aspects relevant to IPSL operations. A high-performance liquid chromatography method for nevirapine was developed with the guidance of the Clinical Pharmacology Quality Assurance programme and approved by the assay method review programme. The University of Zimbabwe IPSL is engaged with the United States National Institute of Allergy and Infectious Diseases Division of AIDS research networks and is poised to begin drug assays and pharmacokinetic analyses. An IPSL has been successfully established in a resource-limited setting through the efforts of an external partnership providing technical guidance and motivated internal faculty and staff. Strategic partnerships were beneficial in navigating challenges leading to laboratory development and training new investigators. The IPSL is now engaged in clinical pharmacology research.

  12. Practical quantum key distribution protocol without monitoring signal disturbance.

    PubMed

    Sasaki, Toshihiko; Yamamoto, Yoshihisa; Koashi, Masato

    2014-05-22

    Quantum cryptography exploits the fundamental laws of quantum mechanics to provide a secure way to exchange private information. Such an exchange requires a common random bit sequence, called a key, to be shared secretly between the sender and the receiver. The basic idea behind quantum key distribution (QKD) has widely been understood as the property that any attempt to distinguish encoded quantum states causes a disturbance in the signal. As a result, implementation of a QKD protocol involves an estimation of the experimental parameters influenced by the eavesdropper's intervention, which is achieved by randomly sampling the signal. If the estimation of many parameters with high precision is required, the portion of the signal that is sacrificed increases, thus decreasing the efficiency of the protocol. Here we propose a QKD protocol based on an entirely different principle. The sender encodes a bit sequence onto non-orthogonal quantum states and the receiver randomly dictates how a single bit should be calculated from the sequence. The eavesdropper, who is unable to learn the whole of the sequence, cannot guess the bit value correctly. An achievable rate of secure key distribution is calculated by considering complementary choices between quantum measurements of two conjugate observables. We found that a practical implementation using a laser pulse train achieves a key rate comparable to a decoy-state QKD protocol, an often-used technique for lasers. It also has a better tolerance of bit errors and of finite-sized-key effects. We anticipate that this finding will give new insight into how the probabilistic nature of quantum mechanics can be related to secure communication, and will facilitate the simple and efficient use of conventional lasers for QKD.

  13. Image use in field guides and identification keys: review and recommendations.

    PubMed

    Leggett, Roxanne; Kirchoff, Bruce K

    2011-01-01

    Although illustrations have played an important role in identification keys and guides since the 18th century, their use has varied widely. Some keys lack all illustrations, while others are heavily illustrated. Even within illustrated guides, the way in which images are used varies considerably. Here, we review image use in paper and electronic guides, and establish a set of best practices for image use in illustrated keys and guides. Our review covers image use in both paper and electronic guides, though we only briefly cover apps for mobile devices. With this one exception, we cover the full range of guides, from those that consist only of species descriptions with no keys, to lavishly illustrated technical keys. Emphasis is placed on how images are used, not on the operation of the guides and key, which has been reviewed by others. We only deal with operation when it impacts image use. Few illustrated keys or guides use images in optimal ways. Most include too few images to show taxonomic variation or variation in characters and character states. The use of multiple images allows easier taxon identification and facilitates the understanding of characters. Most images are usually not standardized, making comparison between images difficult. Although some electronic guides allow images to be enlarged, many do not. The best keys and guides use standardized images, displayed at sizes that are easy to see and arranged in a standardized manner so that similar images can be compared across species. Illustrated keys and glossaries should contain multiple images for each character state so that the user can judge variation in the state. Photographic backgrounds should not distract from the subject and, where possible, should be of a standard colour. When used, drawings should be prepared by professional botanical illustrators, and clearly labelled. Electronic keys and guides should allow images to be enlarged so that their details can be seen.

  14. Image use in field guides and identification keys: review and recommendations

    PubMed Central

    Leggett, Roxanne; Kirchoff, Bruce K.

    2011-01-01

    Background and aims Although illustrations have played an important role in identification keys and guides since the 18th century, their use has varied widely. Some keys lack all illustrations, while others are heavily illustrated. Even within illustrated guides, the way in which images are used varies considerably. Here, we review image use in paper and electronic guides, and establish a set of best practices for image use in illustrated keys and guides. Scope Our review covers image use in both paper and electronic guides, though we only briefly cover apps for mobile devices. With this one exception, we cover the full range of guides, from those that consist only of species descriptions with no keys, to lavishly illustrated technical keys. Emphasis is placed on how images are used, not on the operation of the guides and key, which has been reviewed by others. We only deal with operation when it impacts image use. Main points Few illustrated keys or guides use images in optimal ways. Most include too few images to show taxonomic variation or variation in characters and character states. The use of multiple images allows easier taxon identification and facilitates the understanding of characters. Most images are usually not standardized, making comparison between images difficult. Although some electronic guides allow images to be enlarged, many do not. Conclusions The best keys and guides use standardized images, displayed at sizes that are easy to see and arranged in a standardized manner so that similar images can be compared across species. Illustrated keys and glossaries should contain multiple images for each character state so that the user can judge variation in the state. Photographic backgrounds should not distract from the subject and, where possible, should be of a standard colour. When used, drawings should be prepared by professional botanical illustrators, and clearly labelled. Electronic keys and guides should allow images to be enlarged so that

  15. Environmental Response Laboratory Network (ERLN) Overview

    EPA Pesticide Factsheets

    The Environmental Response Laboratory Network provides Federal, State, and local decision-makers with reliable, high quality analytical data used to identify chemical, biological, and radiological contaminants collected in support of response and cleanup.

  16. Five Keys for Teaching Mental Math

    ERIC Educational Resources Information Center

    Olsen, James R.

    2015-01-01

    After studying the Common Core State Standards for Mathematics (CCSSM) and brain-based learning research, James Olsen believes mental math instruction in secondary school mathematics (grades 7-12) and in teacher education programs needs increased attention. The purpose of this article is to share some keys for teaching mental math. Olsen also…

  17. Experimental measurement-device-independent quantum key distribution with uncharacterized encoding.

    PubMed

    Wang, Chao; Wang, Shuang; Yin, Zhen-Qiang; Chen, Wei; Li, Hong-Wei; Zhang, Chun-Mei; Ding, Yu-Yang; Guo, Guang-Can; Han, Zheng-Fu

    2016-12-01

    Measurement-device-independent quantum key distribution (MDI QKD) is an efficient way to share secrets using untrusted measurement devices. However, the assumption on the characterizations of encoding states is still necessary in this promising protocol, which may lead to unnecessary complexity and potential loopholes in realistic implementations. Here, by using the mismatched-basis statistics, we present the first proof-of-principle experiment of MDI QKD with uncharacterized encoding sources. In this demonstration, the encoded states are only required to be constrained in a two-dimensional Hilbert space, and two distant parties (Alice and Bob) are resistant to state preparation flaws even if they have no idea about the detailed information of their encoding states. The positive final secure key rates of our system exhibit the feasibility of this novel protocol, and demonstrate its value for the application of secure communication with uncharacterized devices.

  18. Experimental Measurement-Device-Independent Quantum Key Distribution

    NASA Astrophysics Data System (ADS)

    Liu, Yang; Chen, Teng-Yun; Wang, Liu-Jun; Liang, Hao; Shentu, Guo-Liang; Wang, Jian; Cui, Ke; Yin, Hua-Lei; Liu, Nai-Le; Li, Li; Ma, Xiongfeng; Pelc, Jason S.; Fejer, M. M.; Peng, Cheng-Zhi; Zhang, Qiang; Pan, Jian-Wei

    2013-09-01

    Quantum key distribution is proven to offer unconditional security in communication between two remote users with ideal source and detection. Unfortunately, ideal devices never exist in practice and device imperfections have become the targets of various attacks. By developing up-conversion single-photon detectors with high efficiency and low noise, we faithfully demonstrate the measurement-device-independent quantum-key-distribution protocol, which is immune to all hacking strategies on detection. Meanwhile, we employ the decoy-state method to defend attacks on a nonideal source. By assuming a trusted source scenario, our practical system, which generates more than a 25 kbit secure key over a 50 km fiber link, serves as a stepping stone in the quest for unconditionally secure communications with realistic devices.

  19. Experimental measurement-device-independent quantum key distribution.

    PubMed

    Liu, Yang; Chen, Teng-Yun; Wang, Liu-Jun; Liang, Hao; Shentu, Guo-Liang; Wang, Jian; Cui, Ke; Yin, Hua-Lei; Liu, Nai-Le; Li, Li; Ma, Xiongfeng; Pelc, Jason S; Fejer, M M; Peng, Cheng-Zhi; Zhang, Qiang; Pan, Jian-Wei

    2013-09-27

    Quantum key distribution is proven to offer unconditional security in communication between two remote users with ideal source and detection. Unfortunately, ideal devices never exist in practice and device imperfections have become the targets of various attacks. By developing up-conversion single-photon detectors with high efficiency and low noise, we faithfully demonstrate the measurement-device-independent quantum-key-distribution protocol, which is immune to all hacking strategies on detection. Meanwhile, we employ the decoy-state method to defend attacks on a nonideal source. By assuming a trusted source scenario, our practical system, which generates more than a 25 kbit secure key over a 50 km fiber link, serves as a stepping stone in the quest for unconditionally secure communications with realistic devices.

  20. Delineation of Waters of the United States for Lawrence Livermore National Laboratory, Site 300

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Preston, R E

    2006-09-25

    This report presents the results of a delineation of waters of the United States, including wetlands, for Lawrence Livermore National Laboratory's Site 300 in Alameda and San Joaquin Counties, California. Jones & Stokes mapped vegetation at Site 300 in August, 2001, using Global Positioning System (GPS) data recorders to collect point locations and to record linear features and map unit polygons. We identified wetlands boundaries in the field on the basis of the plant community present. We returned to collect additional information on wetland soils on July 3, 2002. Forty-six wetlands were identified, with a total area of 3.482 hectaresmore » (8.605 acres). The wetlands include vernal pools, freshwater seeps, and seasonal ponds. Wetlands appearing to meet the criteria for federal jurisdictional total 1.776 hectares (4.388 acres). A delineation map is presented and a table is provided with information on the type, size, characteristic plant species of each wetland, and a preliminary jurisdictional assessment.« less

  1. Evaluations Key to State Chances for NCLB Waiver

    ERIC Educational Resources Information Center

    Sawchuk, Stephen

    2011-01-01

    Where their teacher-quality proposals are concerned, the fates of the 11 states that have bid for waivers of core principles of the No Child Left Behind (NCLB) Act appear to depend largely on how the peer reviewers--and, ultimately, U.S. Secretary of Education Arne Duncan--interpret their applications. The U.S. Department of Education's criteria…

  2. Quantum key distribution with entangled photon sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma Xiongfeng; Fung, Chi-Hang Fred; Lo, H.-K.

    2007-07-15

    A parametric down-conversion (PDC) source can be used as either a triggered single-photon source or an entangled-photon source in quantum key distribution (QKD). The triggering PDC QKD has already been studied in the literature. On the other hand, a model and a post-processing protocol for the entanglement PDC QKD are still missing. We fill in this important gap by proposing such a model and a post-processing protocol for the entanglement PDC QKD. Although the PDC model is proposed to study the entanglement-based QKD, we emphasize that our generic model may also be useful for other non-QKD experiments involving a PDCmore » source. Since an entangled PDC source is a basis-independent source, we apply Koashi and Preskill's security analysis to the entanglement PDC QKD. We also investigate the entanglement PDC QKD with two-way classical communications. We find that the recurrence scheme increases the key rate and the Gottesman-Lo protocol helps tolerate higher channel losses. By simulating a recent 144-km open-air PDC experiment, we compare three implementations: entanglement PDC QKD, triggering PDC QKD, and coherent-state QKD. The simulation result suggests that the entanglement PDC QKD can tolerate higher channel losses than the coherent-state QKD. The coherent-state QKD with decoy states is able to achieve highest key rate in the low- and medium-loss regions. By applying the Gottesman-Lo two-way post-processing protocol, the entanglement PDC QKD can tolerate up to 70 dB combined channel losses (35 dB for each channel) provided that the PDC source is placed in between Alice and Bob. After considering statistical fluctuations, the PDC setup can tolerate up to 53 dB channel losses.« less

  3. Side-channel-free quantum key distribution.

    PubMed

    Braunstein, Samuel L; Pirandola, Stefano

    2012-03-30

    Quantum key distribution (QKD) offers the promise of absolutely secure communications. However, proofs of absolute security often assume perfect implementation from theory to experiment. Thus, existing systems may be prone to insidious side-channel attacks that rely on flaws in experimental implementation. Here we replace all real channels with virtual channels in a QKD protocol, making the relevant detectors and settings inside private spaces inaccessible while simultaneously acting as a Hilbert space filter to eliminate side-channel attacks. By using a quantum memory we find that we are able to bound the secret-key rate below by the entanglement-distillation rate computed over the distributed states.

  4. Encryption key distribution via chaos synchronization

    NASA Astrophysics Data System (ADS)

    Keuninckx, Lars; Soriano, Miguel C.; Fischer, Ingo; Mirasso, Claudio R.; Nguimdo, Romain M.; van der Sande, Guy

    2017-02-01

    We present a novel encryption scheme, wherein an encryption key is generated by two distant complex nonlinear units, forced into synchronization by a chaotic driver. The concept is sufficiently generic to be implemented on either photonic, optoelectronic or electronic platforms. The method for generating the key bitstream from the chaotic signals is reconfigurable. Although derived from a deterministic process, the obtained bit series fulfill the randomness conditions as defined by the National Institute of Standards test suite. We demonstrate the feasibility of our concept on an electronic delay oscillator circuit and test the robustness against attacks using a state-of-the-art system identification method.

  5. Encryption key distribution via chaos synchronization

    PubMed Central

    Keuninckx, Lars; Soriano, Miguel C.; Fischer, Ingo; Mirasso, Claudio R.; Nguimdo, Romain M.; Van der Sande, Guy

    2017-01-01

    We present a novel encryption scheme, wherein an encryption key is generated by two distant complex nonlinear units, forced into synchronization by a chaotic driver. The concept is sufficiently generic to be implemented on either photonic, optoelectronic or electronic platforms. The method for generating the key bitstream from the chaotic signals is reconfigurable. Although derived from a deterministic process, the obtained bit series fulfill the randomness conditions as defined by the National Institute of Standards test suite. We demonstrate the feasibility of our concept on an electronic delay oscillator circuit and test the robustness against attacks using a state-of-the-art system identification method. PMID:28233876

  6. KEY COMPARISON: Final report on CCQM-K44: Trace elements in sewage sludge

    NASA Astrophysics Data System (ADS)

    Aregbe, Y.; Taylor, P. D. P.

    2009-01-01

    CCQM-K44 was an activity of the Inorganic Analysis Working Group (IAWG) of CCQM and was coordinated by the Joint Research Centre-Institute for Reference Materials and Measurements (IRMM, Geel, Belgium) of the European Commission (EC). In CCQM-K44 the amount contents of Cd, Cr, Cu, Pb, Hg, Ni and Zn in sewage sludge were the measurands under investigation. Results were reported by six national metrology institutes (NMIs). During the CCQM-IAWG Spring meeting in Paris, April 2006, the approaches to calculate the KCRV as proposed by the coordinating laboratory were discussed and agreed on. The final report was submitted in June 2006. After the final report had been submitted to the CCQM in June 2006 the coordinating laboratory was informed that MIRS/IJS was not a designated institute and therefore could not represent the Slovenian NMI in CCQM-K44. This was contrary to what MIRS confirmed to the coordinating laboratory at the beginning of CCQM-K44. After several discussions between MIRS and the CCQM the coordinating laboratory was asked to amend the final report accordingly. In this revised version of the CCQM-K44 final report the results of MIRS/IJS were taken out of CCQM-K44 and included in the pilot study CCQM-P70, which was organised in parallel to CCQM-K44. Due to the limited number of participants compared to previous key comparisons the mixture model median (MM-median) of all reported results could not be applied as KCRV for all the measurands. During the CCQM-IAWG Spring meeting in Paris, April 2006, the approaches to calculate the KCRV as proposed by the coordinating laboratory were discussed and first agreed on. As a result the final report and degrees of equivalence were finalised and submitted to the CCQM. Subsequent discussions between the IAWG and the CCQM were held, resulting in a different approach as proposed by the coordinating laboratory. Particularly Maurice Cox from NPL recommended the weighted mean and its standard uncertainty (k = 1) as KCRV

  7. Senior Laboratory Animal Technician | Center for Cancer Research

    Cancer.gov

    PROGRAM DESCRIPTION The Laboratory Animal Sciences Program (LASP) provides exceptional quality animal care and technical support services for animal research performed at the National Cancer Institute at the Frederick National Laboratory for Cancer Research. LASP executes this mission by providing a broad spectrum of state-of-the-art technologies and services that are focused

  8. United States Air Force Summer Research Program -- 1993. Volume 9. Rome Laboratory

    DTIC Science & Technology

    1993-12-01

    Walter Field: Electrical Engineering MS Laboratory: RL/IR Electrical Engineering University of Maine Vol-Page No: 9- 9 Orono, ME 4469-0000 Swindal, J...0000 Tipton, Kevin Field: Zoology MS Laboratory: AL/CF Nutrition and Food Scienc Auburn University Vol-Page No: 7-11 Auburn, AL 36849-5605 Tornow ...deterministic analysis assumed only 1-17 one handling. w ~vA-A-, PPIMAJý PATH Legen(3ND P"ysCaI LinK (forwarid VPC P’ýs Cal L-,* (reverse VPC) Figure 8. OPNET

  9. A brief review on key technologies in the battery management system of electric vehicles

    NASA Astrophysics Data System (ADS)

    Liu, Kailong; Li, Kang; Peng, Qiao; Zhang, Cheng

    2018-04-01

    Batteries have been widely applied in many high-power applications, such as electric vehicles (EVs) and hybrid electric vehicles, where a suitable battery management system (BMS) is vital in ensuring safe and reliable operation of batteries. This paper aims to give a brief review on several key technologies of BMS, including battery modelling, state estimation and battery charging. First, popular battery types used in EVs are surveyed, followed by the introduction of key technologies used in BMS. Various battery models, including the electric model, thermal model and coupled electro-thermal model are reviewed. Then, battery state estimations for the state of charge, state of health and internal temperature are comprehensively surveyed. Finally, several key and traditional battery charging approaches with associated optimization methods are discussed.

  10. Key-value store with internal key-value storage interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bent, John M.; Faibish, Sorin; Ting, Dennis P. J.

    A key-value store is provided having one or more key-value storage interfaces. A key-value store on at least one compute node comprises a memory for storing a plurality of key-value pairs; and an abstract storage interface comprising a software interface module that communicates with at least one persistent storage device providing a key-value interface for persistent storage of one or more of the plurality of key-value pairs, wherein the software interface module provides the one or more key-value pairs to the at least one persistent storage device in a key-value format. The abstract storage interface optionally processes one or moremore » batch operations on the plurality of key-value pairs. A distributed embodiment for a partitioned key-value store is also provided.« less

  11. Guidance, Navigation and Control Digital Emulation Technology Laboratory. Volume 1. Part 2. Task 1: Digital Emulation Technology Laboratory

    DTIC Science & Technology

    1991-09-27

    AD-A241 692 II I] II I11 ANNUAL REPORT VOLUME 1 PART 2 TASK 1: DIGITAL EMULATION TECHNOLOGY LABORATOIRY REPORT NO. AR-0142-91-001 September 27, 1991... DIGITAL EMULATION TECHNOLOGY LABORATORY Contract No. DASG60-89-C-0142 Sponsored By The United States Army ? trategic Defense Command COMPUTER...ANNUAL REPORT VOLUME 1 PART 2 TASK 1: DIGITAL EMULATION TECHNOLOGY LABORATORY September 27, 1991 Authors Thomas R. Collins and Stephen R. Wachtel

  12. Blended learning within an undergraduate exercise physiology laboratory.

    PubMed

    Elmer, Steven J; Carter, Kathryn R; Armga, Austin J; Carter, Jason R

    2016-03-01

    In physiological education, blended course formats (integration of face-to-face and online instruction) can facilitate increased student learning, performance, and satisfaction in classroom settings. There is limited evidence on the effectiveness of using blending course formats in laboratory settings. We evaluated the impact of blended learning on student performance and perceptions in an undergraduate exercise physiology laboratory. Using a randomized, crossover design, four laboratory topics were delivered in either a blended or traditional format. For blended laboratories, content was offloaded to self-paced video demonstrations (∼15 min). Laboratory section 1 (n = 16) completed blended laboratories for 1) neuromuscular power and 2) blood lactate, whereas section 2 (n = 17) completed blended laboratories for 1) maximal O2 consumption and 2) muscle electromyography. Both sections completed the same assignments (scored in a blinded manner using a standardized rubric) and practicum exams (evaluated by two independent investigators). Pre- and postcourse surveys were used to assess student perceptions. Most students (∼79%) watched videos for both blended laboratories. Assignment scores did not differ between blended and traditional laboratories (P = 0.62) or between sections (P = 0.91). Practicum scores did not differ between sections (both P > 0.05). At the end of the course, students' perceived value of the blended format increased (P < 0.01) and a greater percentage of students agreed that learning key foundational content through video demonstrations before class greatly enhanced their learning of course material compared with a preassigned reading (94% vs. 78%, P < 0.01). Blended exercise physiology laboratories provided an alternative method for delivering content that was favorably perceived by students and did not compromise student performance. Copyright © 2016 The American Physiological Society.

  13. Improved Fake-State Attack to the Quantum Key Distribution Systems

    NASA Astrophysics Data System (ADS)

    Zhang, Sheng; Wang, Jian; Tang, Chao-jing

    2012-09-01

    It has been showed that most commercial quantum cryptosystems are vulnerable to the fake-state attacks, which employ the loophole that the avalanche photodiodes as single photon detectors still produce detection events in the linear mode. However, previous fake-state attacks may be easily prevented by either installing a watch dog or reconfiguring the dead-time assigning component. In this paper, we present a new technique to counteract the after-pulse effect ever enhanced by the fake-state attacks, in order to lower the quantum bit error rate. Obviously, it is more difficult to detect the presented attack scheme. Indeed, it contributes to promoting of implementing a secure quantum cryptosystem in real life.

  14. Quantum key distribution with an unknown and untrusted source

    NASA Astrophysics Data System (ADS)

    Zhao, Yi; Qi, Bing; Lo, Hoi-Kwong

    2009-03-01

    The security of a standard bi-directional ``plug & play'' quantum key distribution (QKD) system has been an open question for a long time. This is mainly because its source is equivalently controlled by an eavesdropper, which means the source is unknown and untrusted. Qualitative discussion on this subject has been made previously. In this paper, we present the first quantitative security analysis on a general class of QKD protocols whose sources are unknown and untrusted. The securities of standard BB84 protocol, weak+vacuum decoy state protocol, and one-decoy decoy state protocol, with unknown and untrusted sources are rigorously proved. We derive rigorous lower bounds to the secure key generation rates of the above three protocols. Our numerical simulation results show that QKD with an untrusted source gives a key generation rate that is close to that with a trusted source. Our work is published in [1]. [4pt] [1] Y. Zhao, B. Qi, and H.-K. Lo, Phys. Rev. A, 77:052327 (2008).

  15. Use of Web-based training for quality improvement between a field immunohistochemistry laboratory in Nigeria and its United States-based partner institution.

    PubMed

    Oluwasola, Abideen O; Malaka, David; Khramtsov, Andrey Ilyich; Ikpatt, Offiong Francis; Odetunde, Abayomi; Adeyanju, Oyinlolu Olorunsogo; Sveen, Walmy Elisabeth; Falusi, Adeyinka Gloria; Huo, Dezheng; Olopade, Olufunmilayo Ibironke

    2013-12-01

    The importance of hormone receptor status in assigning treatment and the potential use of human epidermal growth factor receptor 2 (HER2)-targeted therapy have made it beneficial for laboratories to improve detection techniques. Because interlaboratory variability in immunohistochemistry (IHC) tests may also affect studies of breast cancer subtypes in different countries, we undertook a Web-based quality improvement training and a comparative study of accuracy of immunohistochemical tests of breast cancer biomarkers between a well-established laboratory in the United States (University of Chicago) and a field laboratory in Ibadan, Nigeria. Two hundred and thirty-two breast tumor blocks were evaluated for estrogen receptors (ERs), progesterone receptors (PRs), and HER2 status at both laboratories using tissue microarray technique. Initially, concordance analysis revealed κ scores of 0.42 (moderate agreement) for ER, 0.41 (moderate agreement) for PR, and 0.39 (fair agreement) for HER2 between the 2 laboratories. Antigen retrieval techniques and scoring methods were identified as important reasons for discrepancy. Web-based conferences using Web conferencing tools such as Skype and WebEx were then held periodically to discuss IHC staining protocols and standard scoring systems and to resolve discrepant cases. After quality assurance and training, the agreement improved to 0.64 (substantial agreement) for ER, 0.60 (moderate agreement) for PR, and 0.75 (substantial agreement) for HER2. We found Web-based conferences and digital microscopy useful and cost-effective tools for quality assurance of IHC, consultation, and collaboration between distant laboratories. Quality improvement exercises in testing of tumor biomarkers will reduce misclassification in epidemiologic studies of breast cancer subtypes and provide much needed capacity building in resource-poor countries. © 2013.

  16. Laboratory Directed Research and Development FY2001 Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Ayat, R

    2002-06-20

    Established by Congress in 1991, the Laboratory Directed Research and Development (LDRD) Program provides the Department of Energy (DOE)/National Nuclear Security Administration (NNSA) laboratories, like Lawrence Livermore National Laboratory (LLNL or the Laboratory), with the flexibility to invest up to 6% of their budget in long-term, high-risk, and potentially high payoff research and development (R&D) activities to support the DOE/NNSA's national security missions. By funding innovative R&D, the LDRD Program at LLNL develops and extends the Laboratory's intellectual foundations and maintains its vitality as a premier research institution. As proof of the Program's success, many of the research thrusts thatmore » started many years ago under LDRD sponsorship are at the core of today's programs. The LDRD Program, which serves as a proving ground for innovative ideas, is the Laboratory's most important single resource for fostering excellent science and technology for today's needs and tomorrow's challenges. Basic and applied research activities funded by LDRD enhance the Laboratory's core strengths, driving its technical vitality to create new capabilities that enable LLNL to meet DOE/NNSA's national security missions. The Program also plays a key role in building a world-class multidisciplinary workforce by engaging the Laboratory's best researchers, recruiting its future scientists and engineers, and promoting collaborations with all sectors of the larger scientific community.« less

  17. Measuring meaningful learning in the undergraduate chemistry laboratory

    NASA Astrophysics Data System (ADS)

    Galloway, Kelli R.

    The undergraduate chemistry laboratory has been an essential component in chemistry education for over a century. The literature includes reports on investigations of singular aspects laboratory learning and attempts to measure the efficacy of reformed laboratory curriculum as well as faculty goals for laboratory learning which found common goals among instructors for students to learn laboratory skills, techniques, experimental design, and to develop critical thinking skills. These findings are important for improving teaching and learning in the undergraduate chemistry laboratory, but research is needed to connect the faculty goals to student perceptions. This study was designed to explore students' ideas about learning in the undergraduate chemistry laboratory. Novak's Theory of Meaningful Learning was used as a guide for the data collection and analysis choices for this research. Novak's theory states that in order for meaningful learning to occur the cognitive, affective, and psychomotor domains must be integrated. The psychomotor domain is inherent in the chemistry laboratory, but the extent to which the cognitive and affective domains are integrated is unknown. For meaningful learning to occur in the laboratory, students must actively integrate both the cognitive domain and the affective domains into the "doing" of their laboratory work. The Meaningful Learning in the Laboratory Instrument (MLLI) was designed to measure students' cognitive and affective expectations and experiences within the context of conducting experiments in the undergraduate chemistry laboratory. Evidence for the validity and reliability of the data generated by the MLLI were collected from multiple quantitative studies: a one semester study at one university, a one semester study at 15 colleges and universities across the United States, and a longitudinal study where the MLLI was administered 6 times during two years of general and organic chemistry laboratory courses. Results from

  18. 2020 Foresight Forging the Future of Lawrence Livermore National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chrzanowski, P.

    2000-01-01

    The Lawrence Livermore National Laboratory (LLNL) of 2020 will look much different from the LLNL of today and vastly different from how it looked twenty years ago. We, the members of the Long-Range Strategy Project, envision a Laboratory not defined by one program--nuclear weapons research--but by several core programs related to or synergistic with LLNL's national security mission. We expect the Laboratory to be fully engaged with sponsors and the local community and closely partnering with other research and development (R&D) organizations and academia. Unclassified work will be a vital part of the Laboratory of 2020 and will visibly demonstratemore » LLNL's international science and technology strengths. We firmly believe that there will be a critical and continuing role for the Laboratory. As a dynamic and versatile multipurpose laboratory with a national security focus, LLNL will be applying its capabilities in science and technology to meet the needs of the nation in the 21st century. With strategic investments in science, outstanding technical capabilities, and effective relationships, the Laboratory will, we believe, continue to play a key role in securing the nation's future.« less

  19. Keys and the crisis in taxonomy: extinction or reinvention?

    PubMed

    Walter, David Evans; Winterton, Shaun

    2007-01-01

    Dichotomous keys that follow a single pathway of character state choices to an end point have been the primary tools for the identification of unknown organisms for more than two centuries. However, a revolution in computer diagnostics is now under way that may result in the replacement of traditional keys by matrix-based computer interactive keys that have many paths to a correct identification and make extensive use of hypertext to link to images, glossaries, and other support material. Progress is also being made on replacing keys entirely by optical matching of specimens to digital databases and DNA sequences. These new tools may go some way toward alleviating the taxonomic impediment to biodiversity studies and other ecological and evolutionary research, especially with better coordination between those who produce keys and those who use them and by integrating interactive keys into larger biological Web sites.

  20. Multiparty Quantum Key Agreement Based on Quantum Search Algorithm

    PubMed Central

    Cao, Hao; Ma, Wenping

    2017-01-01

    Quantum key agreement is an important topic that the shared key must be negotiated equally by all participants, and any nontrivial subset of participants cannot fully determine the shared key. To date, the embed modes of subkey in all the previously proposed quantum key agreement protocols are based on either BB84 or entangled states. The research of the quantum key agreement protocol based on quantum search algorithms is still blank. In this paper, on the basis of investigating the properties of quantum search algorithms, we propose the first quantum key agreement protocol whose embed mode of subkey is based on a quantum search algorithm known as Grover’s algorithm. A novel example of protocols with 5 – party is presented. The efficiency analysis shows that our protocol is prior to existing MQKA protocols. Furthermore it is secure against both external attack and internal attacks. PMID:28332610

  1. Calculation of key reduction for B92 QKD protocol

    NASA Astrophysics Data System (ADS)

    Mehic, Miralem; Partila, Pavol; Tovarek, Jaromir; Voznak, Miroslav

    2015-05-01

    It is well known that Quantum Key Distribution (QKD) can be used with the highest level of security for distribution of the secret key, which is further used for symmetrical encryption. B92 is one of the oldest QKD protocols. It uses only two non-orthogonal states, each one coding for one bit-value. It is much faster and simpler when compared to its predecessors, but with the idealized maximum efficiencies of 25% over the quantum channel. B92 consists of several phases in which initial key is significantly reduced: secret key exchange, extraction of the raw key (sifting), error rate estimation, key reconciliation and privacy amplification. QKD communication is performed over two channels: the quantum channel and the classical public channel. In order to prevent a man-in-the-middle attack and modification of messages on the public channel, authentication of exchanged values must be performed. We used Wegman-Carter authentication because it describes an upper bound for needed symmetric authentication key. We explained the reduction of the initial key in each of QKD phases.

  2. The Homestake Interim Laboratory and Homestake DUSEL

    NASA Astrophysics Data System (ADS)

    Lesko, Kevin T.

    2011-12-01

    The former Homestake gold mine in Lead South Dakota is proposed for the National Science Foundation's Deep Underground Science and Engineering Laboratory (DUSEL). The gold mine provides expedient access to depths in excess of 8000 feet below the surface (>7000 mwe). Homestake's long history of promoting scientific endeavours includes the Davis Solar Neutrino Experiment, a chlorine-based experiment that was hosted at the 4850 Level for more than 30 years. As DUSEL, Homestake would be uncompromised by competition with mining interests or other shared uses. The facility's 600-km of drifts would be available for conversion for scientific and educational uses. The State of South Dakota, under Governor Rounds' leadership, has demonstrated exceptionally strong support for Homestake and the creation of DUSEL. The State has provided funding totalling $46M for the preservation of the site for DUSEL and for the conversion and operation of the Homestake Interim Laboratory. Motivated by the strong educational and outreach potential of Homestake, the State contracted a Conversion Plan by world-recognized mine-engineering contractor to define the process of rehabilitating the facility, establishing the appropriate safety program, and regaining access to the facility. The State of South Dakota has established the South Dakota Science and Technology Authority to oversee the transfer of the Homestake property to the State and the rehabilitation and preservation of the facility. The Homestake Scientific Collaboration and the State of South Dakota's Science and Technology Authority has called for Letters of Interest from scientific, educational and engineering collaborations and institutions that are interested in hosting experiments and uses in the Homestake Interim Facility in advance of the NSF's DUSEL, to define experiments starting as early as 2007. The Homestake Program Advisory Committee has reviewed these Letters and their initial report has been released. Options for

  3. Implementation of quality management systems and progress towards accreditation of National Tuberculosis Reference Laboratories in Africa

    PubMed Central

    de Dieu Iragena, Jean; Kao, Kekeletso; Erni, Donatelle; Mekonen, Teferi

    2017-01-01

    Background Laboratory services are essential at all stages of the tuberculosis care cascade, from diagnosis and drug resistance testing to monitoring response to treatment. Enabling access to quality services is a challenge in low-resource settings. Implementation of a strong quality management system (QMS) and laboratory accreditation are key to improving patient care. Objectives The study objective was to determine the status of QMS implementation and progress towards accreditation of National Tuberculosis Reference Laboratories (NTRLs) in the African Region. Method An online questionnaire was administered to NTRL managers in 47 World Health Organization Regional Office for Africa member states in the region, between February and April 2015, regarding the knowledge of QMS tools and progress toward implementation to inform strategies for tuberculosis diagnostic services strengthening in the region. Results A total of 21 laboratories (43.0%) had received SLMTA/TB-SLMTA training, of which 10 had also used the Global Laboratory Initiative accreditation tool. However, only 36.7% of NTRLs had received a laboratory audit, a first step in quality improvement. Most NTRLs participated in acid-fast bacilli microscopy external quality assurance (95.8%), although external quality assurance for other techniques was lower (60.4% for first-line drug susceptibility testing, 25.0% for second-line drug susceptibility testing, and 22.9% for molecular testing). Barriers to accreditation included lack of training and accreditation programmes. Only 28.6% of NTRLs had developed strategic plans and budgets which included accreditation. Conclusion Good foundations are in place on the continent from which to scale up accreditation efforts. Laboratory audits should be conducted as a first step in developing quality improvement action plans. Political commitment and strong leadership are needed to drive accreditation efforts; advocacy will require clear evidence of patient impact and cost

  4. Implementation of continuous-variable quantum key distribution with discrete modulation

    NASA Astrophysics Data System (ADS)

    Hirano, Takuya; Ichikawa, Tsubasa; Matsubara, Takuto; Ono, Motoharu; Oguri, Yusuke; Namiki, Ryo; Kasai, Kenta; Matsumoto, Ryutaroh; Tsurumaru, Toyohiro

    2017-06-01

    We have developed a continuous-variable quantum key distribution (CV-QKD) system that employs discrete quadrature-amplitude modulation and homodyne detection of coherent states of light. We experimentally demonstrated automated secure key generation with a rate of 50 kbps when a quantum channel is a 10 km optical fibre. The CV-QKD system utilises a four-state and post-selection protocol and generates a secure key against the entangling cloner attack. We used a pulsed light source of 1550 nm wavelength with a repetition rate of 10 MHz. A commercially available balanced receiver is used to realise shot-noise-limited pulsed homodyne detection. We used a non-binary LDPC code for error correction (reverse reconciliation) and the Toeplitz matrix multiplication for privacy amplification. A graphical processing unit card is used to accelerate the software-based post-processing.

  5. Laboratory Directed Research and Development Annual Report FY 2017

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Kelly O.

    A national laboratory must establish and maintain an environment in which creativity and innovation are encouraged and supported in order to fulfill its missions and remain viable in the long term. As such, multiprogram laboratories are given discretion to allocate a percentage of their operating budgets to support research and development projects that align to PNNL’s and DOE’s missions and support the missions of other federal agencies, including DHS, DOD, and others. DOE Order 413.2C sets forth DOE’s Laboratory Directed Research and Development (LDRD) policy and guidelines for DOE multiprogram laboratories, and it authorizes the national laboratories to allocate upmore » to 6 percent of their operating budgets to fund the program. LDRD is innovative research and development, selected by the Laboratory Director or his/her designee, for the purpose of maintaining the scientific and technological vitality of the Laboratory. The projects supported by LDRD funding all have demonstrable ties to DOE/DHS missions and may also be relevant to the missions of other federal agencies that sponsor work at the Laboratory. The program plays a key role in attracting the best and brightest scientific staff, which is needed to serve the highest priority DOE mission objectives. Individual project reports comprise the bulk of this LDRD report. The Laboratory focuses its LDRD research on scientific assets that often address more than one scientific discipline.« less

  6. Laboratory Directed Research and Development Annual Report FY 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Kelly O.

    A national laboratory must establish and maintain an environment in which creativity and innovation are encouraged and supported in order to fulfill its missions and remain viable in the long term. As such, multiprogram laboratories are given discretion to allocate a percentage of their operating budgets to support research and development projects that align to PNNL’s and DOE’s missions and support the missions of other federal agencies, including DHS, DOD, and others. DOE Order 413.2C sets forth DOE’s Laboratory Directed Research and Development (LDRD) policy and guidelines for DOE multiprogram laboratories, and it authorizes the national laboratories to allocate upmore » to 6 percent of their operating budgets to fund the program. LDRD is innovative research and development, selected by the Laboratory Director or his/her designee, for the purpose of maintaining the scientific and technological vitality of the Laboratory. The projects supported by LDRD funding all have demonstrable ties to DOE/DHS missions and may also be relevant to the missions of other federal agencies that sponsor work at the Laboratory. The program plays a key role in attracting the best and brightest scientific staff, which is needed to serve the highest priority DOE mission objectives. Individual project reports comprise the bulk of this LDRD report. The Laboratory focuses its LDRD research on scientific assets that often address more than one scientific discipline.« less

  7. Artist's Concept of NASA's Propulsion Research Laboratory

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A new, world-class laboratory for research into future space transportation technologies is under construction at the Marshall Space Flight Center (MSFC) in Huntsville, AL. The state-of-the-art Propulsion Research Laboratory will serve as a leading national resource for advanced space propulsion research. Its purpose is to conduct research that will lead to the creation and development of irnovative propulsion technologies for space exploration. The facility will be the epicenter of the effort to move the U.S. space program beyond the confines of conventional chemical propulsion into an era of greatly improved access to space and rapid transit throughout the solar system. The Laboratory is designed to accommodate researchers from across the United States, including scientists and engineers from NASA, the Department of Defense, the Department of Energy, universities, and industry. The facility, with 66,000 square feet of useable laboratory space, will feature a high degree of experimental capability. Its flexibility will allow it to address a broad range of propulsion technologies and concepts, such as plasma, electromagnetic, thermodynamic, and propellantless propulsion. An important area of emphasis will be development and utilization of advanced energy sources, including highly energetic chemical reactions, solar energy, and processes based on fission, fusion, and antimatter. The Propulsion Research Laboratory is vital for developing the advanced propulsion technologies needed to open up the space frontier, and will set the stage of research that could revolutionize space transportation for a broad range of applications.

  8. LABORATORY AND COMPUTATIONAL INVESTIGATIONS OF THE ATMOSPHERIC CHEMISTRY OF KEY OXIDATION PRODUCTS CONTROLLING TROPOSPHERIC OZONE FORMATION

    EPA Science Inventory

    Major uncertainties remain in our ability to identify the key reactions and primary oxidation products of volatile hydrocarbons that contribute to ozone formation in the troposphere. To reduce these uncertainties, computational chemistry, mechanistic and process analysis techniqu...

  9. Experimental Demonstration of Polarization Encoding Measurement-Device-Independent Quantum Key Distribution

    NASA Astrophysics Data System (ADS)

    Tang, Zhiyuan; Liao, Zhongfa; Xu, Feihu; Qi, Bing; Qian, Li; Lo, Hoi-Kwong

    2014-05-01

    We demonstrate the first implementation of polarization encoding measurement-device-independent quantum key distribution (MDI-QKD), which is immune to all detector side-channel attacks. Active phase randomization of each individual pulse is implemented to protect against attacks on imperfect sources. By optimizing the parameters in the decoy state protocol, we show that it is feasible to implement polarization encoding MDI-QKD with commercial off-the-shelf devices. A rigorous finite key analysis is applied to estimate the secure key rate. Our work paves the way for the realization of a MDI-QKD network, in which the users only need compact and low-cost state-preparation devices and can share complicated and expensive detectors provided by an untrusted network server.

  10. Experimental demonstration of polarization encoding measurement-device-independent quantum key distribution.

    PubMed

    Tang, Zhiyuan; Liao, Zhongfa; Xu, Feihu; Qi, Bing; Qian, Li; Lo, Hoi-Kwong

    2014-05-16

    We demonstrate the first implementation of polarization encoding measurement-device-independent quantum key distribution (MDI-QKD), which is immune to all detector side-channel attacks. Active phase randomization of each individual pulse is implemented to protect against attacks on imperfect sources. By optimizing the parameters in the decoy state protocol, we show that it is feasible to implement polarization encoding MDI-QKD with commercial off-the-shelf devices. A rigorous finite key analysis is applied to estimate the secure key rate. Our work paves the way for the realization of a MDI-QKD network, in which the users only need compact and low-cost state-preparation devices and can share complicated and expensive detectors provided by an untrusted network server.

  11. NATIONAL RISK MANAGEMENT RESEARCH LABORATORY: PROVIDING SOLUTIONS FOR A BETTER TOMORROW

    EPA Science Inventory

    This small, two-fold flyer contains general information introducing EPA's National Risk Management Research Laboratory and its research program. The key overarching areas of research described are: Protection of drinking water; control of air pollution; pollution prevention and e...

  12. Learn About Laboratory Certification for Drinking Water

    EPA Pesticide Factsheets

    EPA’s Office of Water Technical Support Center implements the Drinking Water Laboratory Certification Program in partnership with EPA Regions, EPA’s Office of Research and Development, and States.

  13. Florida Keys

    NASA Image and Video Library

    2002-12-13

    The Florida Keys are a chain of islands, islets and reefs extending from Virginia Key to the Dry Tortugas for about 309 kilometers (192 miles). The keys are chiefly limestone and coral formations. The larger islands of the group are Key West (with its airport), Key Largo, Sugarloaf Key, and Boca Chica Key. A causeway extends from the mainland to Key West. This image was acquired on October 28, 2001, by the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) on NASA's Terra satellite. With its 14 spectral bands from the visible to the thermal infrared wavelength region, and its high spatial resolution of 15 to 90 meters (about 50 to 300 feet), ASTER images Earth to map and monitor the changing surface of our planet. http://photojournal.jpl.nasa.gov/catalog/PIA03890

  14. National Water Quality Laboratory - A Profile

    USGS Publications Warehouse

    Raese, Jon W.

    2001-01-01

    The U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL) is a full-service laboratory that specializes in environmental analytical chemistry. The NWQL's primary mission is to support USGS programs requiring environmental analyses that provide consistent methodology for national assessment and trends analysis. The NWQL provides the following: high-quality chemical data; consistent, published, state-of-the-art methodology; extremely low-detection levels; high-volume capability; biological unit for identifying benthic invertebrates; quality assurance for determining long-term water-quality trends; and a professional staff.

  15. An innovative educational approach to professional development of medical laboratory scientists in Botswana.

    PubMed

    Magowe, Mabel Km; Ledikwe, Jenny H; Kasvosve, Ishmael; Martin, Robert; Thankane, Kabo; Semo, Bazghina-Werq

    2014-01-01

    To address the shortage of laboratory scientists in Botswana, an innovative, one-year academic bridging program was initiated at the University of Botswana, to advance diploma-holding laboratory technicians towards becoming laboratory scientists holding Bachelor's degrees. An evaluation was conducted, which described the outcomes of the program and the lessons learned from this novel approach to meeting human resource needs. This was a cross-sectional, mixed-methods evaluation. Qualitative interviews were conducted with graduates of the Bachelor of Science (BSc) Medical Laboratory Sciences (MLS) bridging program, along with the graduates' current supervisors, and key informants who were involved in program development or implementation. The quantitative data collected included a written questionnaire, completed by program graduates, with a retrospective pre-test/post-test survey of graduates' confidence, in terms of key laboratory competencies. The BSc MLS bridging program produced thirty-three laboratory scientists over 3 years. There was a significant increase in confidence among graduates, for specified competencies, after the program (P<0.05). Graduates reported acquiring new skills and, often, accepting new responsibilities at their former workplace, particularly in relationship to leadership and management. Five graduates enrolled in advanced degree programs. Most graduates assumed increased responsibility. However, only two graduates were promoted after completing the training program. The lessons learned include: the importance of stakeholder involvement, the need for data to identify local needs, financial sustainability, catering for the needs of adult learners, and ensuring a technically challenging work environment, conducive to the application of skills learned during training. A strong public health and clinical laboratory system is essential for the rapid detection and control of emerging health threats, and for patient care. However, there is a need

  16. Crystal Growth Furnace System Configuration and Planned Experiments on the Second United States Microgravity Laboratory Mission

    NASA Technical Reports Server (NTRS)

    Srinivas, R.; Hambright, G.; Ainsworth, M.; Fiske, M.; Schaefer, D.

    1995-01-01

    The Crystal Growth Furnace (CGF) is currently undergoing modifications and refurbishment and is currently undergoing modifications and refurbishment and is manifested to refly on the Second United States Microgravity Laboratory (USML-2) mission scheduled for launch in September 1995. The CGF was developed for the National Aeronautics and Space Administration (NASA) under the Microgravity Science and Applications Division (MSAD) programs at NASA Headquarters. The refurbishment and reflight program is being managed by the Marshall Space Flight Center (MSFC) in Huntsville, Alabama. Funding and program support for the CGF project is provided to MSFC by the office of Life and Microgravity Sciences and Applications at NASA Headquarters. This paper presents an overview of the CGF system configuration for the USML-2 mission, and provides a brief description of the planned on-orbit experiment operation.

  17. Guidelines for Biosafety Training Programs for Workers Assigned to BSL-3 Research Laboratories.

    PubMed

    Homer, Lesley C; Alderman, T Scott; Blair, Heather Ann; Brocard, Anne-Sophie; Broussard, Elaine E; Ellis, Robert P; Frerotte, Jay; Low, Eleanor W; McCarthy, Travis R; McCormick, Jessica M; Newton, JeT'Aime M; Rogers, Francine C; Schlimgen, Ryan; Stabenow, Jennifer M; Stedman, Diann; Warfield, Cheryl; Ntiforo, Corrie A; Whetstone, Carol T; Zimmerman, Domenica; Barkley, Emmett

    2013-03-01

    The Guidelines for Biosafety Training Programs for Workers Assigned to BSL-3 Research Laboratories were developed by biosafety professionals who oversee training programs for the 2 national biocontainment laboratories (NBLs) and the 13 regional biocontainment laboratories (RBLs) that participate in the National Institute of Allergy and Infectious Diseases (NIAID) NBL/RBL Network. These guidelines provide a general training framework for biosafety level 3 (BSL-3) high-containment laboratories, identify key training concepts, and outline training methodologies designed to standardize base knowledge, understanding, and technical competence of laboratory personnel working in high-containment laboratories. Emphasis is placed on building a culture of risk assessment-based safety through competency training designed to enhance understanding and recognition of potential biological hazards as well as methods for controlling these hazards. These guidelines may be of value to other institutions and academic research laboratories that are developing biosafety training programs for BSL-3 research.

  18. Solid State Research, 1980:1.

    DTIC Science & Technology

    1980-02-15

    ESD-TR-79-325 H 1 Solid State Research 1980 Prepared under Electronic Systems Division Contract FI%28-80-C-0002 by Lincoln Laboratory MASSkCHIISETTS...it is no longer needed. MASSACHUSETTS IN*STITUTE OF TECHNOLOGY LINCOLN LABORATORY V SOLID STATE RESEARCH QUARTERLY TECHNICAL SUMMARY REPORT I NOVEMBER...January 1990. The topics covered a-e Solid State Device Research , Quantum Electronics, Materials Rese.rch, Microelec- tronics, and Analog Device

  19. Critical Value Reporting at Egyptian Laboratories.

    PubMed

    Mosallam, Rasha; Ibrahim, Samaa Zenhom

    2015-06-12

    To examine critical value reporting policies and practices and to identify critical value ranges for selected common laboratory assays at inpatient division of laboratories of Alexandria hospitals. A cross-sectional descriptive study design was used. Subjects were from inpatient division of all laboratories of Alexandria hospitals (40 laboratories). Data were collected using a questionnaire composed of 4 sections. The first section explored hospital and laboratory characteristics. The second section assessed policies and procedures of critical value reporting. The third section explored the reporting process. The fourth section explored critical value ranges for selected common laboratory assays. Written procedure for reporting of critical values was present in 77.5% of laboratories and a comprehensive list of critical values in 72.55%. For laboratories having a critical value list, the number of tests in the list ranged from 7 to 40. Three-fifths of laboratories had a policy for assessing the timeliness of reporting and 3 quarters stated that the laboratory policy requires feedback (60.0% and 75.0%, respectively). The hospital laboratory physician was responsible for critical value reporting followed by the laboratory technician (75.0% and 50.0%, respectively). The call is received mainly by nurses and physicians ordering the test (67.5% and 55.0%, respectively) and the channel of reporting is mainly the telephone or through sending test report to the ward (67.5% and 50.0%, respectively). Wireless technologies are used in reporting in only 10.0% of hospitals. The cutoff limits for reporting different assays showed considerable interlaboratory variation. Critical value policies and practices showed interinstitutional variation with deficiencies in some reporting practices. Selection of critical assays for notification and setting the limits of notification exhibited wide variation as well.

  20. Survey of 2014 behavioral management programs for laboratory primates in the United States.

    PubMed

    Baker, Kate C

    2016-07-01

    The behavioral management of laboratory nonhuman primates in the United States has not been thoroughly characterized since 2003. This article presents the results of a survey behavioral management programs at 27 facilities and covering a total of 59,636 primates, 27,916 housed in indoor cages and 31,720 in group enclosures. The survey included questions regarding program structure, implementation, and methodology associated with social housing, positive reinforcement training, positive human interaction, exercise enclosures, and several categories of inanimate enrichment. The vast majority of laboratory primates are housed socially (83%). Since 2003, the proportion of indoor-housed primates reported to be housed singly has fallen considerably, from 59% to 35% in the facilities surveyed. The use of social housing remains significantly constrained by: 1) research protocol requirements, highlighting the value of closely involved IACUCs for harmonizing research and behavioral management; and 2) the unavailability of compatible social partners, underscoring the necessity of objective analysis of the methods used to foster and maintain compatibility. Positive reinforcement training appears to have expanded and is now used at all facilities responding to the survey. The use of enrichment devices has also increased in the participating facilities. For most behavioral management techniques, concerns over the possibility of negative consequences to animals are expressed most frequently for social housing and destructible enrichment, while skepticism regarding efficacy is limited almost exclusively to sensory enrichment. Behavioral management program staffing has expanded over time in the facilities surveyed, due not only to increased numbers of dedicated behavioral management technicians but also to greater involvement of animal care technicians, suggesting an increase in the integration of behavioral care into animal husbandry. Broad awareness of common practice may assist

  1. Tritium laboratory with multiple purposes at NIPNE Magurele Romania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matei, L.; Postolache, C.

    2008-07-15

    The Tritium Laboratory from NIPNE (Romania)) is part of Radioisotope Research and Production Center. The Tritium Laboratory has been in operation since 1960, and carries out R and D activities involving tritium sources in gaseous, liquids and solid state, provides specialized service to CANDU NPP Cernavoda (Romania)), and provides tritium assay services to internal and external customers. The paper presents the activities and perspectives of Tritium Laboratory and its performances in accordance with Quality System Management. (authors)

  2. The role of laboratory testing in detection and classification of chronic kidney disease: national recommendations

    PubMed Central

    Biljak, Vanja Radišić; Honović, Lorena; Matica, Jasminka; Krešić, Branka; Vojak, Sanela Šimić

    2017-01-01

    Chronic kidney disease (CKD) is a common clinical condition with significant adverse consequences for the patient and it is recognized as a significant public health problem. The role of laboratory medicine in diagnosis and management of CKD is of great importance: the diagnosis and staging are based on estimation of glomerular filtration rate (eGFR) and assessment of albuminuria (or proteinuria). Therefore, the joint working group of the Croatian society of medical biochemistry and laboratory medicine and Croatian chamber of medical biochemists for laboratory diagnostics in CKD issued this national recommendation regarding laboratory diagnostics of CKD.
Key factors for laboratories implementing the national guidelines for the diagnosis and management of CKD are:
1. Ensure good communication between laboratory professionals and clinicians, such as nephrologists or specialists in general/family medicine,
2. Ensure all patients are provided with the same availability of laboratory diagnostics,
3. Ensure creatinine assays are traceable to isotope dilution mass spectrometry (IDMS) method and have minimal bias and acceptable imprecision,
4. Select the appropriate GFR estimating formula. Recommended equation is the 2009 Chronic Kidney Disease Epidemiology Collaboration (CKD – EPI) equation,
5. In reporting the key laboratory tests (creatinine, eGFR, urine albumin-to-creatinine ratio, urine protein-to-creatinine ratio) use the appropriate reporting units,
6. Provide adequate information on limitations of creatinine measurement.
The manuscript has been organized to identify critical points in laboratory tests used in basic laboratory diagnostics of CKD and is based on the Kidney Disease: Improving Global Outcomes (KDIGO) 2012 Clinical Practice Guideline for the Evaluation and Management of Chronic Kidney Disease. PMID:28392738

  3. Initial Public Health Laboratory Response After Hurricane Maria - Puerto Rico, 2017.

    PubMed

    Concepción-Acevedo, Jeniffer; Patel, Anita; Luna-Pinto, Carolina; Peña, Rafael González; Cuevas Ruiz, Rosa Ivette; Arbolay, Héctor Rivera; Toro, Mayra; Deseda, Carmen; De Jesus, Victor R; Ribot, Efrain; Gonzalez, Jennifer-Quiñones; Rao, Gouthami; De Leon Salazar, Alfonsina; Ansbro, Marisela; White, Brunilís B; Hardy, Margaret C; Georgi, Joaudimir Castro; Stinnett, Rita; Mercante, Alexandra M; Lowe, David; Martin, Haley; Starks, Angela; Metchock, Beverly; Johnston, Stephanie; Dalton, Tracy; Joglar, Olga; Stafford, Cortney; Youngblood, Monica; Klein, Katherine; Lindstrom, Stephen; Berman, LaShondra; Galloway, Renee; Schafer, Ilana J; Walke, Henry; Stoddard, Robyn; Connelly, Robin; McCaffery, Elaine; Rowlinson, Marie-Claire; Soroka, Stephen; Tranquillo, Darin T; Gaynor, Anne; Mangal, Chris; Wroblewski, Kelly; Muehlenbachs, Atis; Salerno, Reynolds M; Lozier, Matthew; Sunshine, Brittany; Shapiro, Craig; Rose, Dale; Funk, Renee; Pillai, Satish K; O'Neill, Eduardo

    2018-03-23

    Hurricane Maria made landfall in Puerto Rico on September 20, 2017, causing major damage to infrastructure and severely limiting access to potable water, electric power, transportation, and communications. Public services that were affected included operations of the Puerto Rico Department of Health (PRDOH), which provides critical laboratory testing and surveillance for diseases and other health hazards. PRDOH requested assistance from CDC for the restoration of laboratory infrastructure, surveillance capacity, and diagnostic testing for selected priority diseases, including influenza, rabies, leptospirosis, salmonellosis, and tuberculosis. PRDOH, CDC, and the Association of Public Health Laboratories (APHL) collaborated to conduct rapid needs assessments and, with assistance from the CDC Foundation, implement a temporary transport system for shipping samples from Puerto Rico to the continental United States for surveillance and diagnostic and confirmatory testing. This report describes the initial laboratory emergency response and engagement efforts among federal, state, and nongovernmental partners to reestablish public health laboratory services severely affected by Hurricane Maria. The implementation of a sample transport system allowed Puerto Rico to reinitiate priority infectious disease surveillance and laboratory testing for patient and public health interventions, while awaiting the rebuilding and reinstatement of PRDOH laboratory services.

  4. Election 2000: The Keys Point to Gore.

    ERIC Educational Resources Information Center

    Lichtman, Allan J.

    2000-01-01

    Asserts that Vice President Al Gore will be elected in 2000 based on the performance of the Clinton administration. Utilizes the key to the White House, 13 true-or-false diagnostic questions stated as propositions. If five or less are false then the party in power wins. (CMK)

  5. A Low Cost Microcomputer Laboratory for Investigating Computer Architecture.

    ERIC Educational Resources Information Center

    Mitchell, Eugene E., Ed.

    1980-01-01

    Described is a microcomputer laboratory at the United States Military Academy at West Point, New York, which provides easy access to non-volatile memory and a single input/output file system for 16 microcomputer laboratory positions. A microcomputer network that has a centralized data base is implemented using the concepts of computer network…

  6. Overview of EPA Pesticide Laboratories and Methods

    EPA Pesticide Factsheets

    EPA operates two pesticide laboratories that provide a variety of technical services to the Agency, other federal and state agencies, tribal groups and other organizations.The labs develop methods and procedures.

  7. The AAPT Advanced Laboratory Task Force Report

    NASA Astrophysics Data System (ADS)

    Dunham, Jeffrey

    2008-04-01

    In late 2005, the American Association of Physics Teachers (AAPT) assembled a seven-member Advanced Laboratory Task Force^ to recommend ways that AAPT could increase the degree and effectiveness of its interactions with physics teachers of upper-division physics laboratories, with the ultimate goal of improving the teaching of advanced laboratories. The task force completed its work during the first half of 2006 and its recommendations were presented to the AAPT Executive Committee in July 2006. This talk will present the recommendations of the task force and actions taken by AAPT in response to them. The curricular goals of the advanced laboratory course at various institutions will also be discussed. The talk will conclude with an appeal to the APS membership to support ongoing efforts to revitalize advanced laboratory course instruction. ^Members of the Advanced Laboratory Task Force: Van Bistrow, University of Chicago; Bob DeSerio, University of Florida; Jeff Dunham, Middlebury College (Chair); Elizabeth George, Wittenburg University; Daryl Preston, California State University, East Bay; Patricia Sparks, Harvey Mudd College; Gerald Taylor, James Madison University; and David Van Baak, Calvin College.

  8. Crystal Growth Furnace - An overview of the system configuration and planned experiments on the First United States Microgravity Laboratory mission

    NASA Technical Reports Server (NTRS)

    Srinivas, R.; Schaefer, D. A.

    1992-01-01

    The Crystal Growth Furnace (CGF) system configuration for the First United States Microgravity Laboratory (USML-1) mission is reviewed, and the planned on-orbit experiments are briefly described. The CGF is configured to accommodate four scientific experiments involving crystal growth which are based on the classical Bridgman method and CVT method, including vapor transport crystal growth of mercury cadmium telluride; crystal growth of mercury zinc telluride by directional solidification; seeded Bridgman growth of zinc-doped cadmium telluride; and Bridgman growth of selenium-doped gallium arsenide.

  9. Laboratory Molecular Astrophysics as an Invaluable Tool in understanding Astronomical Observations.

    NASA Astrophysics Data System (ADS)

    Fraser, Helen Jane

    2015-08-01

    We are entering the decade of molecular astrochemistry: spectroscopic data pertaining to the interactions between baryonic matter and electromagnetic radiation are now at the forefront of astronomical observations. Elucidating such data is reliant on inputs from laboratory experiments, modeling, and theoretical chemistry / physics, a field that is intended to be a key focus for the proposed new commission in Laboratory Astrophysics.Here, we propose a “tour de force” review of some recent successes since the last GA in molecular astrophysics, particularly those that have been directly facilitated by laboratory data in Astrochemistry. It is vital to highlight to the astronomers that the absence of laboratory data from the literature would otherwise have precluded advances in our astronomical understanding, e.g:the detection of gas-phase water deep in pre-stellar cores,the detection of water and other molecular species in gravitationally lensed galaxies at z~6“Jumps” in the appearance or disappearance of molecules, including the very recent detection of the first branched organic molecule in the ISM, iso-propyl-cyanide,disentangling dense spectroscopic features in the sub-mm as measured by ALMA, Herschel and SOFIA, the so-called “weeds” and “flowers”,the first ''image'' of a CO snow-line in a protoplanetary disk.Looking forward, the advent of high spatial and spectral resolution telescopes, particularly ALMA, SKA E-ELT and JWST, will continue to drive forward the needs and interests of laboratory astrochemistry in the coming decade. We will look forward to five key areas where advances are expected, and both observational and laboratory techniques are evolving:-(a) understanding star forming regions at very high spatial and spectral senstivity and resolution(b) extragalactic astrochemistry(c) (exo-)planetary atmospheres, surfaces and Solar System sample return - linkinginterstellar and planetary chemistry(d) astrobiology - linking simple molecular

  10. EPA/ORD NATIONAL EXPOSURE RESEARCH LABORATORY MEASUREMENT SCIENCE SUPPORT FOR HOMELAND SECURITY

    EPA Science Inventory

    This product describes the National Exposure Research Laboratory research and development support for homeland security through the proposed National Exposure Measurements Center (NEMC). Key NEMC functional areas depicted in this poster are: standardized analytical method develo...

  11. Function key and shortcut key use in airway facilities.

    DOT National Transportation Integrated Search

    2003-02-01

    This document provides information on the function keys and shortcut keys used by systems in the Federal Aviation Administration : Airway Facilities (AF) work environment. It includes a catalog of the function keys and shortcut keys used by each syst...

  12. The instruments in the first psychological laboratory in Mexico: antecedents, influence, and methods.

    PubMed

    Escobar, Rogelio

    2014-11-01

    Enrique O. Aragón established the first psychological laboratory in Mexico in 1916. This laboratory was inspired by Wundt's laboratory and by those created afterward in Germany and the United States. It was equipped with state-of-the art instruments imported from Germany in 1902 from Ernst Zimmermann who supplied instruments for Wundt's laboratory. Although previous authors have described the social events leading to the creation of the laboratory, there are limited descriptions of the instruments, their use, and their influence. With the aid of archival resources, the initial location of the laboratory was determined. The analysis of instruments revealed a previously overlooked relation with a previous laboratory of experimental physiology. The influence of the laboratory was traced by describing the careers of 4 students, 3 of them women, who worked with the instruments during the first 2 decades of the 20th century, each becoming accomplished scholars. In addition, this article, by identifying and analyzing the instruments shown in photographs of the psychological laboratory and in 1 motion film, provides information of the class demonstrations and the experiments conducted in this laboratory.

  13. Scaling up Evidence-based Practices for Children and Families in New York State: Towards Evidence-based Policies on Implementation for State Mental Health Systems

    PubMed Central

    Hoagwood, Kimberly Eaton; Olin, S. Serene; Horwitz, Sarah; McKay, Mary; Cleek, Andrew; Gleacher, Alissa; Lewandowski, Eric; Nadeem, Erum; Acri, Mary; Chor, Ka Ho Brian; Kuppinger, Anne; Burton, Geraldine; Weiss, Dara; Frank, Samantha; Finnerty, Molly; Bradbury, Donna M.; Woodlock, Kristin M.; Hogan, Michael

    2014-01-01

    Dissemination of innovations is widely considered the sine qua non for system improvement. At least two dozen states are rolling-out evidence-based mental health practices targeted at children and families using trainings, consultations, webinars, and learning collaboratives to improve quality and outcomes. In New York State (NYS) a group of researchers, policy-makers, providers and family support specialists have worked in partnership since 2002 to redesign and evaluate the children’s mental health system. Five system strategies driven by empirically-based practices and organized within a state-supported infrastructure have been used in the child and family service system with over 2,000 providers: (a) business practices; (b) use of health information technologies in quality improvement; (c) specific clinical interventions targeted at common childhood disorders; (d) parent activation; and (e) quality indicator development. The NYS system has provided a laboratory for naturalistic experiments. We describe these initiatives, key findings and challenges, lessons learned for scaling, and implications for creating evidence-based implementation policies in state systems. PMID:24460518

  14. Talk and community: The place of reporting in a life sciences laboratory

    NASA Astrophysics Data System (ADS)

    Swieringa, Robert Cecil

    This study investigates the routine situated communicative practice within the weekly meetings of a life sciences laboratory. The key, constitutive discourse of "reporting" is examined as an activity in which participants jointly sustain the work community of the laboratory and manage their own work within this community. This study seeks to contribute to studies of small groups by focusing upon the multifunctionality and situated nature of the meeting interactions within this enduring "bona fide" group as participants undertake multiple goals associated with their own progress and with the overlapping contexts of the setting. It also seeks to contribute to investigations of institutional talk and activity by examining "reporting" as interaction with institutional and community consequences for members of the community. This study takes a practice-oriented perspective to investigate the laboratory as a community of practice, focusing upon the "activity" of interaction as the overall unit of analysis. Ethnographic materials (involving observation, interviews, conversations, and activity logs) and discourse analysis techniques (involving audiotaping and transcriptions of meetings) were used to locate and record data within a university entomology laboratory over a two year period. Through triangulation of data, "reporting" is identified as a key discourse activity within the laboratory. As situated communicative practice within the weekly meetings, reporting is found to be compelled discourse through which interactants interactively manage one's ongoing goals and activity while temporally situating that activity within the broader stream of laboratory work. This study provides an example of how engagement in situated discursive activity provides for the coordination of individual lines of progress within the ongoing work of a community.

  15. Solution-Phase Synthesis of Dipeptides: A Capstone Project That Employs Key Techniques in an Organic Laboratory Course

    ERIC Educational Resources Information Center

    Marchetti, Louis; DeBoef, Brenton

    2015-01-01

    A contemporary approach to the synthesis and purification of several UV-active dipeptides has been developed for the second-year organic laboratory. This experiment exposes students to the important technique of solution-phase peptide synthesis and allows an instructor to highlight the parallel between what they are accomplishing in the laboratory…

  16. PULSAR: A High-Repetition-Rate, High-Power, CE Phase-Locked Laser for the J.R. Macdonald Laboratory at Kansas State University

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ben-Itzhak, Itzik; Carnes, Kevin D.; Cocke, C. Lew

    2014-05-09

    This instrumentation grant funded the development and installation of a state-of-the-art laser system to be used for the DOE funded research at the J.R. Macdonald Laboratory at Kansas State University. Specifically, we purchased a laser based on the KMLABs Red-Dragon design, which has a high repetition rate of 10-20 kHz crucial for multi-parameter coincidence measurements conducted in our lab. This laser system is carrier-envelope phase (CEP) locked and provides pulses as short as 21 fs directly from the amplifier (see details below). In addition, we have developed a pulse compression setup that provides sub 5 fs pulses and a CEPmore » tagging capability that allows for long measurements of CEP dependent processes.« less

  17. PaR-PaR Laboratory Automation Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linshiz, G; Stawski, N; Poust, S

    2013-05-01

    Labor-intensive multistep biological tasks, such as the construction and cloning of DNA molecules, are prime candidates for laboratory automation. Flexible and biology-friendly operation of robotic equipment is key to its successful integration in biological laboratories, and the efforts required to operate a robot must be much smaller than the alternative manual lab work. To achieve these goals, a simple high-level biology-friendly robot programming language is needed. We have developed and experimentally validated such a language: Programming a Robot (PaR-PaR). The syntax and compiler for the language are based on computer science principles and a deep understanding of biological workflows. PaR-PaRmore » allows researchers to use liquid-handling robots effectively, enabling experiments that would not have been considered previously. After minimal training, a biologist can independently write complicated protocols for a robot within an hour. Adoption of PaR-PaR as a standard cross-platform language would enable hand-written or software-generated robotic protocols to be shared across laboratories.« less

  18. PaR-PaR laboratory automation platform.

    PubMed

    Linshiz, Gregory; Stawski, Nina; Poust, Sean; Bi, Changhao; Keasling, Jay D; Hillson, Nathan J

    2013-05-17

    Labor-intensive multistep biological tasks, such as the construction and cloning of DNA molecules, are prime candidates for laboratory automation. Flexible and biology-friendly operation of robotic equipment is key to its successful integration in biological laboratories, and the efforts required to operate a robot must be much smaller than the alternative manual lab work. To achieve these goals, a simple high-level biology-friendly robot programming language is needed. We have developed and experimentally validated such a language: Programming a Robot (PaR-PaR). The syntax and compiler for the language are based on computer science principles and a deep understanding of biological workflows. PaR-PaR allows researchers to use liquid-handling robots effectively, enabling experiments that would not have been considered previously. After minimal training, a biologist can independently write complicated protocols for a robot within an hour. Adoption of PaR-PaR as a standard cross-platform language would enable hand-written or software-generated robotic protocols to be shared across laboratories.

  19. KEY COMPARISON: Final report on international key comparison CCQM-K53: Oxygen in nitrogen

    NASA Astrophysics Data System (ADS)

    Lee, Jeongsoon; Bok Lee, Jin; Moon, Dong Min; Seog Kim, Jin; van der Veen, Adriaan M. H.; Besley, Laurie; Heine, Hans-Joachim; Martin, Belén; Konopelko, L. A.; Kato, Kenji; Shimosaka, Takuya; Perez Castorena, Alejandro; Macé, Tatiana; Milton, Martin J. T.; Kelley, Mike; Guenther, Franklin; Botha, Angelique

    2010-01-01

    Gravimetry is used as the primary method for the preparation of primary standard gas mixtures in most national metrology institutes, and it requires the combined abilities of purity assessment, weighing technique and analytical skills. At the CCQM GAWG meeting in October 2005, it was agreed that KRISS should coordinate a key comparison, CCQM-K53, on the gravimetric preparation of gas, at a level of 100 µmol/mol of oxygen in nitrogen. KRISS compared the gravimetric value of each cylinder with an analytical instrument. A preparation for oxygen gas standard mixture requires particular care to be accurate, because oxygen is a major component of the atmosphere. Key issues for this comparison are related to (1) the gravimetric technique which needs at least two steps for dilution, (2) oxygen impurity in nitrogen, and (3) argon impurity in nitrogen. The key comparison reference value is obtained from the linear regression line (with origin) of a selected set of participants. The KCRV subset, except one, agree with each other. The standard deviation of the x-residuals of this group (which consists of NMIJ, VSL, NIST, NPL, BAM, KRISS and CENAM) is 0.056 µmol/mol and consistent with the uncertainties given to their standard mixtures. The standard deviation of the residuals of all participating laboratory is 0.182 µmol/mol. With respect to impurity analysis, overall argon amounts of the cylinders are in the region of about 3 µmol/mol however; four cylinders showed an argon amount fraction over 10 µmol/mol. Two of these are inconsistent with the KCRV subset. The explicit separation between two peaks of oxygen and argon in the GC chromatogram is essential to maintain analytical capability. Additionally oxygen impurity analysis in nitrogen is indispensable to ensure the preparative capability. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The

  20. Efficient multiparty quantum key agreement with collective detection.

    PubMed

    Huang, Wei; Su, Qi; Liu, Bin; He, Yuan-Hang; Fan, Fan; Xu, Bing-Jie

    2017-11-10

    As a burgeoning branch of quantum cryptography, quantum key agreement is a kind of key establishing processes where the security and fairness of the established common key should be guaranteed simultaneously. However, the difficulty on designing a qualified quantum key agreement protocol increases significantly with the increase of the number of the involved participants. Thus far, only few of the existing multiparty quantum key agreement (MQKA) protocols can really achieve security and fairness. Nevertheless, these qualified MQKA protocols are either too inefficient or too impractical. In this paper, an MQKA protocol is proposed with single photons in travelling mode. Since only one eavesdropping detection is needed in the proposed protocol, the qubit efficiency and measurement efficiency of it are higher than those of the existing ones in theory. Compared with the protocols which make use of the entangled states or multi-particle measurements, the proposed protocol is more feasible with the current technologies. Security and fairness analysis shows that the proposed protocol is not only immune to the attacks from external eavesdroppers, but also free from the attacks from internal betrayers.