Sample records for t1 weighted images

  1. Hybrid nanotrimers for dual T 1 and T 2-weighted magnetic resonance imaging

    DOE PAGES

    Cheng, Kai; Yang, Meng; Zhang, Ruiping; ...

    2014-10-04

    Development of multifunctional nanoparticle-based probes for dual T 1- and T 2-weighted magnetic resonance imaging (MRI) could allow us to image and diagnose the tumors or other abnormalities in an exceptionally accurate and reliable manner. In this study, by fusing distinct nanocrystals via solid-state interfaces, we built hybrid heteronanostructures to combine both T 1 and T 2- weighted contrast agents together for MRI with high accuracy and reliability. The resultant hybrid heterotrimers showed high stability in physiological conditions and could induce both simultaneous positive and negative contrast enhancements in MR images. Small animal positron emission tomography imaging study revealed thatmore » the hybrid heterostructures displayed favorable biodistribution and were suitable for in vivo imaging. Furthermore, their potential as dual contrast agents for T 1 and T 2-weighted MRI was further demonstrated by in vitro and in vivo imaging and relaxivity measurements.« less

  2. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, J; Son, J; Arun, B

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a singlemore » acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol

  3. T1ρ-weighted Dynamic Glucose-enhanced MR Imaging in the Human Brain.

    PubMed

    Paech, Daniel; Schuenke, Patrick; Koehler, Christina; Windschuh, Johannes; Mundiyanapurath, Sibu; Bickelhaupt, Sebastian; Bonekamp, David; Bäumer, Philipp; Bachert, Peter; Ladd, Mark E; Bendszus, Martin; Wick, Wolfgang; Unterberg, Andreas; Schlemmer, Heinz-Peter; Zaiss, Moritz; Radbruch, Alexander

    2017-12-01

    Purpose To evaluate the ability to detect intracerebral regions of increased glucose concentration at T1ρ-weighted dynamic glucose-enhanced (DGE) magnetic resonance (MR) imaging at 7.0 T. Materials and Methods This prospective study was approved by the institutional review board. Nine patients with newly diagnosed glioblastoma and four healthy volunteers were included in this study from October 2015 to July 2016. Adiabatically prepared chemical exchange-sensitive spin-lock imaging was performed with a 7.0-T whole-body unit with a temporal resolution of approximately 7 seconds, yielding the time-resolved DGE contrast. T1ρ-weighted DGE MR imaging was performed with injection of 100 mL of 20% d-glucose via the cubital vein. Glucose enhancement, given by the relative signal intensity change at T1ρ-weighted MR imaging (DGEρ), was quantitatively investigated in brain gray matter versus white matter of healthy volunteers and in tumor tissue versus normal-appearing white matter of patients with glioblastoma. The median signal intensities of the assessed brain regions were compared by using the Wilcoxon rank-sum test. Results In healthy volunteers, the median signal intensity in basal ganglia gray matter (DGEρ = 4.59%) was significantly increased compared with that in white matter tissue (DGEρ = 0.65%) (P = .028). In patients, the median signal intensity in the glucose-enhanced tumor region as displayed on T1ρ-weighted DGE images (DGEρ = 2.02%) was significantly higher than that in contralateral normal-appearing white matter (DGEρ = 0.08%) (P < .0001). Conclusion T1ρ-weighted DGE MR imaging in healthy volunteers and patients with newly diagnosed, untreated glioblastoma enabled visualization of brain glucose physiology and pathophysiologically increased glucose uptake and may have the potential to provide information about glucose metabolism in tumor tissue. © RSNA, 2017 Online supplemental material is available for this article.

  4. SU-F-R-35: Repeatability of Texture Features in T1- and T2-Weighted MR Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahon, R; Weiss, E; Karki, K

    Purpose: To evaluate repeatability of lung tumor texture features from inspiration/expiration MR image pairs for potential use in patient specific care models and applications. Repeatability is a desirable and necessary characteristic of features included in such models. Methods: T1-weighted Volumetric Interpolation Breath-Hold Examination (VIBE) and/or T2-weighted MRI scans were acquired for 15 patients with non-small cell lung cancer before and during radiotherapy for a total of 32 and 34 same session inspiration-expiration breath-hold image pairs respectively. Bias correction was applied to the VIBE (VIBE-BC) and T2-weighted (T2-BC) images. Fifty-nine texture features at five wavelet decomposition ratios were extracted from themore » delineated primary tumor including: histogram(HIST), gray level co-occurrence matrix(GLCM), gray level run length matrix(GLRLM), gray level size zone matrix(GLSZM), and neighborhood gray tone different matrix (NGTDM) based features. Repeatability of the texture features for VIBE, VIBE-BC, T2-weighted, and T2-BC image pairs was evaluated by the concordance correlation coefficient (CCC) between corresponding image pairs, with a value greater than 0.90 indicating repeatability. Results: For the VIBE image pairs, the percentage of repeatable texture features by wavelet ratio was between 20% and 24% of the 59 extracted features; the T2-weighted image pairs exhibited repeatability in the range of 44–49%. The percentage dropped to 10–20% for the VIBE-BC images, and 12–14% for the T2-BC images. In addition, five texture features were found to be repeatable in all four image sets including two GLRLM, two GLZSM, and one NGTDN features. No single texture feature category was repeatable among all three image types; however, certain categories performed more consistently on a per image type basis. Conclusion: We identified repeatable texture features on T1- and T2-weighted MRI scans. These texture features should be further investigated

  5. Cortical pathology in multiple sclerosis detected by the T1/T2‐weighted ratio from routine magnetic resonance imaging

    PubMed Central

    Righart, Ruthger; Biberacher, Viola; Jonkman, Laura E.; Klaver, Roel; Schmidt, Paul; Buck, Dorothea; Berthele, Achim; Kirschke, Jan S.; Zimmer, Claus; Hemmer, Bernhard; Geurts, Jeroen J. G.

    2017-01-01

    Objective In multiple sclerosis, neuropathological studies have shown widespread changes in the cerebral cortex. In vivo imaging is critical, because the histopathological substrate of most measurements is unknown. Methods Using a novel magnetic resonance imaging analysis technique, based on the ratio of T1‐ and T2‐weighted signal intensities, we studied the cerebral cortex of a large cohort of patients in early stages of multiple sclerosis. A total of 168 patients with clinically isolated syndrome or relapsing–remitting multiple sclerosis (Expanded Disability Status Scale: median = 1, range = 0–3.5) and 80 age‐ and sex‐matched healthy controls were investigated. We also searched for the histopathological substrate of the T1/T2‐weighted ratio by combining postmortem imaging and histopathology in 9 multiple sclerosis brain donors. Results Patients showed lower T1/T2‐weighted ratio values in parietal and occipital areas. The 4 most significant clusters appeared in the medial occipital and posterior cingulate cortex (each left and right). The decrease of the T1/T2‐weighted ratio in the posterior cingulate was related to performance in attention. Analysis of the T1/T2‐weighted ratio values of postmortem imaging yielded a strong correlation with dendrite density but none of the other parameters including myelin. Interpretation The T1/T2‐weighted ratio decreases in early stages of multiple sclerosis in a widespread manner, with a preponderance of posterior areas and with a contribution to attentional performance; it seems to reflect dendrite pathology. As the method is broadly available and applicable to available clinical scans, we believe that it is a promising candidate for studying and monitoring cortical pathology or therapeutic effects in multiple sclerosis. Ann Neurol 2017;82:519–529 PMID:28833433

  6. Fat suppression at three-dimensional T1-weighted MR imaging of the hands: Dixon method versus CHESS technique.

    PubMed

    Kirchgesner, T; Perlepe, V; Michoux, N; Larbi, A; Vande Berg, B

    2018-01-01

    To compare the effectiveness of fat suppression and the image quality of the Dixon method with those of the chemical shift-selective (CHESS) technique in hands of normal subjects at non-enhanced three-dimensional (3D) T1-weighted MR imaging. Both hands of 14 healthy volunteers were imaged with 3D fast spoiled gradient echo (FSPGR) T1-weighted Dixon, 3D FSPGR T1-weighted CHESS and 3D T1-weighted fast spin echo (FSE) CHESS sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFS BM ) and soft tissues (EFS ST ) in 20 joints per subject. One radiologist measured the signal-to-noise ratio (SNR) in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects (P<0.0083), paired t-test (P<0.05) and observed agreement to assess differences in effectiveness of fat suppression, differences in SNR and interobserver agreement. EFS BM was statistically significantly higher for the 3D FSPGR T1-weighted Dixon than for the 3D FSPGR T1-weighted CHESS sequence and the 3D FSE T1-weighted CHESS sequence (P<0.0001). EFS ST was statistically significantly higher for the 3D FSPGR T1-weighted Dixon than for the 3D FSPGR T1-weighted CHESS sequence (P<0.0011) and for the 3D FSE T1-weighted CHESS sequence in the axial plane (P=0.0028). Mean SNR was statistically significantly higher for 3D FSPGR T1-weighted Dixon sequence than for 3D FSPGR T1-weighted CHESS and 3D FSE T1-weighted CHESS sequences (P<0.0001). The Dixon method yields more effective fat suppression and higher SNR than the CHESS technique at 3D T1-weighted MR imaging of the hands. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  7. High signal intensity of intervertebral calcified disks on T1-weighted MR images resulting from fat content.

    PubMed

    Malghem, Jacques; Lecouvet, Frédéric E; François, Robert; Vande Berg, Bruno C; Duprez, Thierry; Cosnard, Guy; Maldague, Baudouin E

    2005-02-01

    To explain a cause of high signal intensity on T1-weighted MR images in calcified intervertebral disks associated with spinal fusion. Magnetic resonance and radiological examinations of 13 patients were reviewed, presenting one or several intervertebral disks showing a high signal intensity on T1-weighted MR images, associated both with the presence of calcifications in the disks and with peripheral fusion of the corresponding spinal segments. Fusion was due to ligament ossifications (n=8), ankylosing spondylitis (n=4), or posterior arthrodesis (n=1). Imaging files included X-rays and T1-weighted MR images in all cases, T2-weighted MR images in 12 cases, MR images with fat signal suppression in 7 cases, and a CT scan in 1 case. Histological study of a calcified disk from an anatomical specimen of an ankylosed lumbar spine resulting from ankylosing spondylitis was examined. The signal intensity of the disks was similar to that of the bone marrow or of perivertebral fat both on T1-weighted MR images and on all sequences, including those with fat signal suppression. In one of these disks, a strongly negative absorption coefficient was focally measured by CT scan, suggesting a fatty content. The histological examination of the ankylosed calcified disk revealed the presence of well-differentiated bone tissue and fatty marrow within the disk. The high signal intensity of some calcified intervertebral disks on T1-weighted MR images can result from the presence of fatty marrow, probably related to a disk ossification process in ankylosed spines.

  8. Breast cancer detection using double reading of unenhanced MRI including T1-weighted, T2-weighted STIR, and diffusion-weighted imaging: a proof of concept study.

    PubMed

    Trimboli, Rubina M; Verardi, Nicola; Cartia, Francesco; Carbonaro, Luca A; Sardanelli, Francesco

    2014-09-01

    The purpose of this study was to investigate the diagnostic performance of unenhanced MRI in detecting breast cancer and to assess the impact of double reading. A total of 116 breasts of 67 women who were 36-89 years old were studied at 1.5 T using an unenhanced protocol including axial T1-weighted gradient-echo, T2-weighted STIR, and echo-planar diffusion-weighted imaging (DWI). Two blinded readers (R1 and R2) independently evaluated unenhanced images using the BIRADS scale. A combination of pathology and negative follow-up served as the reference standard. McNemar and kappa statistics were used. Per-breast cancer prevalence was 37 of 116 (32%): 30 of 37 (81%) invasive ductal carcinoma, five of 37 (13%) ductal carcinoma in situ, and two of 37 (6%) invasive lobular carcinoma. Per-breast sensitivity of unenhanced MRI was 29 of 37 (78%) for R1, 28 of 37 (76%) for R2, and 29 of 37 (78%) for double reading. Specificity was 71 of 79 (90%) for both R1 and R2 and 69 of 79 (87%) for double reading. Double reading did not provide a significant increase in sensitivity. Interobserver agreement was almost perfect (Cohen κ = 0.873). An unenhanced breast MRI protocol composed of T1-weighted gradient echo, T2-weighted STIR, and echo-planar DWI enabled breast cancer detection with sensitivity of 76-78% and specificity of 90% without a gain in sensitivity from double reading.

  9. Optimization of PROPELLER reconstruction for free-breathing T1-weighted cardiac imaging.

    PubMed

    Huang, Teng-Yi; Tseng, Yu-Shen; Tang, Yu-Wei; Lin, Yi-Ru

    2012-08-01

    Clinical cardiac MR imaging techniques generally require patients to hold their breath during the scanning process to minimize respiratory motion-related artifacts. However, some patients cannot hold their breath because of illness or limited breath-hold capacity. This study aims to optimize the PROPELLER reconstruction for free-breathing myocardial T1-weighted imaging. Eight healthy volunteers (8 men; mean age 26.4 years) participated in this study after providing institutionally approved consent. The PROPELLER encoding method can reconstruct a low-resolution image from every blade because of k-space center oversampling. This study investigated the feasibility of extracting a respiratory trace from the PROPELLER blades by implementing a fully automatic region of interest selection and introducing a best template index to account for the property of the human respiration cycle. Results demonstrated that the proposed algorithm significantly improves the contrast-to-noise ratio and the image sharpness (p < 0.05). The PROPELLER method is expected to provide a robust tool for clinical application in free-breathing myocardial T1-weighted imaging. It could greatly facilitate the acquisition procedures during such a routine examination.

  10. Spot Sign in Acute Intracerebral Hemorrhage in Dynamic T1-Weighted Magnetic Resonance Imaging.

    PubMed

    Schindlbeck, Katharina A; Santaella, Anna; Galinovic, Ivana; Krause, Thomas; Rocco, Andrea; Nolte, Christian H; Villringer, Kersten; Fiebach, Jochen B

    2016-02-01

    In computed tomographic imaging of acute intracerebral hemorrhage spot sign on computed tomographic angiography has been established as a marker for hematoma expansion and poor clinical outcome. Although, magnetic resonance imaging (MRI) can accurately visualize acute intracerebral hemorrhage, a corresponding MRI marker is lacking to date. We prospectively examined 50 consecutive patients with acute intracerebral hemorrhage within 24 hours of symptom onset. The MRI protocol consisted of a standard stroke protocol and dynamic contrast-enhanced T1-weighted imaging with a time resolution of 7.07 s/batch. Stroke scores were assessed at admission and at time of discharge. Volume measurements of hematoma size and spot sign were performed with MRIcron. Contrast extravasation within sites of the hemorrhage (MRI spot sign) was seen in 46% of the patients. Patients with an MRI spot sign had a significantly shorter time to imaging than those without (P<0.001). The clinical outcome measured by the modified Rankin Scale was significantly worse in patients with spot sign compared with those without (P≤0.001). Hematoma expansion was observed in the spot sign group compared with the nonspot sign group, although the differences were not significant. Spot sign can be detected using MRI on postcontrast T1-weighted and dynamic T1-weighted images. It is associated with worse clinical outcome. The time course of contrast extravasation in dynamic T1 images indicates that these spots represent ongoing bleeding. © 2015 American Heart Association, Inc.

  11. STrategically Acquired Gradient Echo (STAGE) imaging, part I: Creating enhanced T1 contrast and standardized susceptibility weighted imaging and quantitative susceptibility mapping.

    PubMed

    Chen, Yongsheng; Liu, Saifeng; Wang, Yu; Kang, Yan; Haacke, E Mark

    2018-02-01

    To provide whole brain grey matter (GM) to white matter (WM) contrast enhanced T1W (T1WE) images, multi-echo quantitative susceptibility mapping (QSM), proton density (PD) weighted images, T1 maps, PD maps, susceptibility weighted imaging (SWI), and R2* maps with minimal misregistration in scanning times <5min. Strategically acquired gradient echo (STAGE) imaging includes two fully flow compensated double echo gradient echo acquisitions with a resolution of 0.67×1.33×2.0mm 3 acquired in 5min for 64 slices. Ten subjects were recruited and scanned at 3 Tesla. The optimum pair of flip angles (6° and 24° with TR=25ms at 3T) were used for both T1 mapping with radio frequency (RF) transmit field correction and creating enhanced GM/WM contrast (the T1WE). The proposed T1WE image was created from a combination of the proton density weighted (6°, PDW) and T1W (24°) images and corrected for RF transmit field variations. Prior to the QSM calculation, a multi-echo phase unwrapping strategy was implemented using the unwrapped short echo to unwrap the longer echo to speed up computation. R2* maps were used to mask deep grey matter and veins during the iterative QSM calculation. A weighted-average sum of susceptibility maps was generated to increase the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). The proposed T1WE image has a significantly improved CNR both for WM to deep GM and WM to cortical GM compared to the acquired T1W image (the first echo of 24° scan) and the T1MPRAGE image. The weighted-average susceptibility maps have 80±26%, 55±22%, 108±33% SNR increases across the ten subjects compared to the single echo result of 17.5ms for the putamen, caudate nucleus, and globus pallidus, respectively. STAGE imaging offers the potential to create a standardized brain imaging protocol providing four pieces of quantitative tissue property information and multiple types of qualitative information in just 5min. Published by Elsevier Inc.

  12. A voxel based comparative analysis using magnetization transfer imaging and T1-weighted magnetic resonance imaging in progressive supranuclear palsy

    PubMed Central

    Sandhya, Mangalore; Saini, Jitender; Pasha, Shaik Afsar; Yadav, Ravi; Pal, Pramod Kumar

    2014-01-01

    Aims: In progressive supranuclear palsy (PSP) tissue damage occurs in specific cortical and subcortical regions. Voxel based analysis using T1-weighted images depict quantitative gray matter (GM) atrophy changes. Magnetization transfer (MT) imaging depicts qualitative changes in the brain parenchyma. The purpose of our study was to investigate whether MT imaging could indicate abnormalities in PSP. Settings and Design: A total of 10 patients with PSP (9 men and 1 woman) and 8 controls (5 men and 3 women) were studied with T1-weighted magnetic resonance imaging (MRI) and 3DMT imaging. Voxel based analysis of T1-weighted MRI was performed to investigate brain atrophy while MT was used to study qualitative abnormalities in the brain tissue. We used SPM8 to investigate group differences (with two sample t-test) using the GM and white matter (WM) segmented data. Results: T1-weighted imaging and MT are equally sensitive to detect changes in GM and WM in PSP. Magnetization transfer ratio images and magnetization-prepared rapid acquisition of gradient echo revealed extensive bilateral volume and qualitative changes in the orbitofrontal, prefrontal cortex and limbic lobe and sub cortical GM. The prefrontal structures involved were the rectal gyrus, medial, inferior frontal gyrus (IFG) and middle frontal gyrus (MFG). The anterior cingulate, cingulate gyrus and lingual gyrus of limbic lobe and subcortical structures such as caudate, thalamus, insula and claustrum were also involved. Cerebellar involvement mainly of anterior lobe was also noted. Conclusions: The findings suggest that voxel based MT imaging permits a whole brain unbiased investigation of central nervous system structural integrity in PSP. PMID:25024571

  13. Europium-doped gadolinium sulfide nanoparticles as a dual-mode imaging agent for T1-weighted MR and photoluminescence imaging.

    PubMed

    Jung, Jongjin; Kim, Mi Ae; Cho, Jee-Hyun; Lee, Seung Jae; Yang, Ilseung; Cho, Janggeun; Kim, Seong Keun; Lee, Chulhyun; Park, Joung Kyu

    2012-08-01

    We present a facile synthesis of europium-doped gadolinium sulfide (GdS:Eu(3+)) opto-magnetic nanoparticles (NPs) via sonochemistry. Their photoluminescence and strong paramagnetic properties enable these NPs to be utilized as an in vitro cell imaging and in vivo T(1)-weighted MR imaging probe. The GdS:Eu(3+) NPs have a prominent longitudinal (r(1)) relaxivity value, which is a critical parameter for T(1)-weighted MR imaging. Here, we showed not only their strong positive contrast effect to blood vessels and organs of mice, but also blood half-life and biodistribution including clearance from organs, in order to assess the GdS:Eu(3+) NPs as a competent nanocrystal-based T(1) contrast agent. We further showed confocal images of breast cancer cells containing GdS:Eu(3+) NPs to evaluate as a photoluminescence probe. Dual-mode imaging capability obtained from the GdS:Eu(3+) NPs will allow target-oriented cellular imaging as well as the resulting disease-specific MR imaging. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Contrast-enhanced fluid-attenuated inversion recovery vs. contrast-enhanced spin echo T1-weighted brain imaging.

    PubMed

    Falzone, Cristian; Rossi, Federica; Calistri, Maurizio; Tranquillo, Massimo; Baroni, Massimo

    2008-01-01

    In humans, contrast-enhanced fluid-attenuated inversion recovery (FLAIR) imaging plays an important role in detecting brain disease. The aim of this study was to define the clinical utility of contrast-enhanced FLAIR imaging by comparing the results with those with contrast-enhanced spin echo T1-weighted images (SE T1WI) in animals with different brain disorders. Forty-one dogs and five cats with a clinical suspicion of brain disease and 30 normal animals (25 dogs and five cats) were evaluated using a 0.2 T permanent magnet. Before contrast medium injection, spin echo T1-weighted, SE T1WI, and FLAIR sequences were acquired in three planes. SE T1WI and FLAIR images were also acquired after gadolinium injection. Sensitivity in detecting the number, location, margin, and enhancement pattern and rate were evaluated. No lesions were found in a normal animal. In affected animals, 48 lesions in 34 patients were detected in contrast-enhanced SE T1WI whereas 81 lesions in 44 patients were detected in contrast-enhanced FLAIR images. There was no difference in the characteristics of the margins or enhancement pattern of the detected lesions. The objective enhancement rate, the mean value between lesion-to-white matter ratio and lesion-to-gray matter ratio, although representing an overlap of T1 and T2 effects and not pure contrast medium shortening of T1 relaxation, was better in contrast-enhanced FLAIR images. These results suggest a superiority of contrast-enhanced FLAIR images as compared with contrast-enhanced SE T1WI in detecting enhancing brain lesions.

  15. Three-dimensional T1rho-weighted MRI at 1.5 Tesla.

    PubMed

    Borthakur, Arijitt; Wheaton, Andrew; Charagundla, Sridhar R; Shapiro, Erik M; Regatte, Ravinder R; Akella, Sarma V S; Kneeland, J Bruce; Reddy, Ravinder

    2003-06-01

    To design and implement a magnetic resonance imaging (MRI) pulse sequence capable of performing three-dimensional T(1rho)-weighted MRI on a 1.5-T clinical scanner, and determine the optimal sequence parameters, both theoretically and experimentally, so that the energy deposition by the radiofrequency pulses in the sequence, measured as the specific absorption rate (SAR), does not exceed safety guidelines for imaging human subjects. A three-pulse cluster was pre-encoded to a three-dimensional gradient-echo imaging sequence to create a three-dimensional, T(1rho)-weighted MRI pulse sequence. Imaging experiments were performed on a GE clinical scanner with a custom-built knee-coil. We validated the performance of this sequence by imaging articular cartilage of a bovine patella and comparing T(1rho) values measured by this sequence to those obtained with a previously tested two-dimensional imaging sequence. Using a previously developed model for SAR calculation, the imaging parameters were adjusted such that the energy deposition by the radiofrequency pulses in the sequence did not exceed safety guidelines for imaging human subjects. The actual temperature increase due to the sequence was measured in a phantom by a MRI-based temperature mapping technique. Following these experiments, the performance of this sequence was demonstrated in vivo by obtaining T(1rho)-weighted images of the knee joint of a healthy individual. Calculated T(1rho) of articular cartilage in the specimen was similar for both and three-dimensional and two-dimensional methods (84 +/- 2 msec and 80 +/- 3 msec, respectively). The temperature increase in the phantom resulting from the sequence was 0.015 degrees C, which is well below the established safety guidelines. Images of the human knee joint in vivo demonstrate a clear delineation of cartilage from surrounding tissues. We developed and implemented a three-dimensional T(1rho)-weighted pulse sequence on a 1.5-T clinical scanner. Copyright 2003

  16. Quantitative DLA-based compressed sensing for T1-weighted acquisitions

    NASA Astrophysics Data System (ADS)

    Svehla, Pavel; Nguyen, Khieu-Van; Li, Jing-Rebecca; Ciobanu, Luisa

    2017-08-01

    High resolution Manganese Enhanced Magnetic Resonance Imaging (MEMRI), which uses manganese as a T1 contrast agent, has great potential for functional imaging of live neuronal tissue at single neuron scale. However, reaching high resolutions often requires long acquisition times which can lead to reduced image quality due to sample deterioration and hardware instability. Compressed Sensing (CS) techniques offer the opportunity to significantly reduce the imaging time. The purpose of this work is to test the feasibility of CS acquisitions based on Diffusion Limited Aggregation (DLA) sampling patterns for high resolution quantitative T1-weighted imaging. Fully encoded and DLA-CS T1-weighted images of Aplysia californica neural tissue were acquired on a 17.2T MRI system. The MR signal corresponding to single, identified neurons was quantified for both versions of the T1 weighted images. For a 50% undersampling, DLA-CS can accurately quantify signal intensities in T1-weighted acquisitions leading to only 1.37% differences when compared to the fully encoded data, with minimal impact on image spatial resolution. In addition, we compared the conventional polynomial undersampling scheme with the DLA and showed that, for the data at hand, the latter performs better. Depending on the image signal to noise ratio, higher undersampling ratios can be used to further reduce the acquisition time in MEMRI based functional studies of living tissues.

  17. Comparison of contrast-enhanced T1-weighted FLAIR with BLADE, and spin-echo T1-weighted sequences in intracranial MRI.

    PubMed

    Alkan, Ozlem; Kizilkiliç, Osman; Yildirim, Tülin; Alibek, Sedat

    2009-06-01

    We compared periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER, BLADE) MR technique with spin echo (SE) technique for evaluation of artifacts, and detection and delineation of brain lesions. Contrast-enhanced T1-weighted fluid attenuated inversion recovery (FLAIR) images with BLADE technique (CE T1W-FLAIR BLADE) and contrast-enhanced T1-weighted SE (CE T1W-SE) were performed in 50 patients with intracranial enhancing lesions. These techniques were compared by two neuroradiologists for qualitative analysis of artifacts, lesion detectability, lesion delineation from adjacent structures, and preferred imaging technique; and for quantitative variables, i.e., lesion-to-background and lesion-to-cerebrospinal fluid (CSF) contrast-to-noise (CNR) ratios. Reader agreement was assessed by kappa statistics. All lesions depicted with the CE T1W-SE were also detected with the CE T1W-FLAIR BLADE technique. Delineation of lesions was better on CE T1W-FLAIR BLADE in the majority of patients. Flow-related artifacts were considerably reduced with CE T1W-FLAIR BLADE. A star-like artifact at the level of the 4(th) ventricle was noted on CE T1W-FLAIR BLADE but not on CE T1W-SE. The lesion-to-background CNR and lesion-to-CSF CNR did not show a statistically significant difference between the two techniques. CE T1W-FLAIR BLADE images were preferred by the observers over the CE T1w-SE images, indicating good interobserver agreement (k = 0.70). CE T1W-FLAIR BLADE technique is superior to CE T1WSE for delineation of lesions and reduction of flow-related artifacts, especially within the posterior fossa, and is preferred by readers. CE T1W-FLAIR BLADE may be an alternative approach to imaging, especially for posterior fossa lesions.

  18. Low-Molecular-Weight Iron Chelates May Be an Alternative to Gadolinium-based Contrast Agents for T1-weighted Contrast-enhanced MR Imaging.

    PubMed

    Boehm-Sturm, Philipp; Haeckel, Akvile; Hauptmann, Ralf; Mueller, Susanne; Kuhl, Christiane K; Schellenberger, Eyk A

    2018-02-01

    Purpose To synthesize two low-molecular-weight iron chelates and compare their T1 contrast effects with those of a commercial gadolinium-based contrast agent for their applicability in dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging. Materials and Methods The animal experiments were approved by the local ethics committee. Two previously described iron (Fe) chelates of pentetic acid (Fe-DTPA) and of trans-cyclohexane diamine tetraacetic acid (Fe-tCDTA) were synthesized with stability constants several orders of magnitude higher than those of gadolinium-based contrast agents. The T1 contrast effects of the two chelates were compared with those of gadopentetate dimeglumine in blood serum phantoms at 1.5 T, 3 T, and 7 T. For in vivo studies, a human breast cancer cell line (MDA-231) was implanted in five mice per group. The dynamic contrast effects of the chelates were compared by performing DCE MR imaging with intravenous application of Fe-DTPA or Fe-tCDTA on day 1 and DCE MR imaging in the same tumors with gadopentetate dimeglumine on day 2. Quantitative DCE maps were generated with software and were compared by means of a one-tailed Pearson correlation test. Results Relaxivities in serum (0.94 T at room temperature) of Fe-tCDTA (r1 = 2.2 mmol -1 · sec -1 , r2 = 2.5 mmol -1 · sec -1 ) and Fe-DTPA (r1 = 0.9 mmol -1 · sec -1 , r2 = 0.9 mmol -1 · sec -1 ) were approximately twofold and fivefold lower, respectively, compared with those of gadopentetate dimeglumine (r1 = 4.1 mmol -1 · sec -1 , r2 = 4.8 mmol -1 · sec -1 ). Used at moderately higher concentrations, however, iron chelates generated similar contrast effects at T1-weighted MR imaging in vitro in serum, in vivo in blood, and for DCE MR imaging of breast cancer xenografts. The volume transfer constant values for Fe-DTPA and Fe-tCDTA in the same tumors correlated well with those observed for gadopentetate dimeglumine (Fe-tCDTA Pearson R, 0.99; P = .0003; Fe-DTPA Pearson R, 0.97; P

  19. Preoperative detection of malignant liver tumors: Comparison of 3D-T2-weighted sequences with T2-weighted turbo spin-echo and single shot T2 at 1.5 T.

    PubMed

    Barat, Maxime; Soyer, Philippe; Dautry, Raphael; Pocard, Marc; Lo-Dico, Rea; Najah, Haythem; Eveno, Clarisse; Cassinotto, Christophe; Dohan, Anthony

    2018-03-01

    To assess the performances of three-dimensional (3D)-T2-weighted sequences compared to standard T2-weighted turbo spin echo (T2-TSE), T2-half-Fourier acquisition single-shot turbo spin-echo (T2-HASTE), diffusion weighted imaging (DWI) and 3D-T1-weighted VIBE sequences in the preoperative detection of malignant liver tumors. From 2012 to 2015, all patients of our institution undergoing magnetic resonance imaging (MRI) examination for suspected malignant liver tumors were prospectively included. Patients had contrast-enhanced 3D-T1-weighted, DWI, 3D-T2-SPACE, T2-HASTE and T2-TSE sequences. Imaging findings were compared with those obtained at follow-up, surgery and histopathological analysis. Sensitivities for the detection of malignant liver tumors were compared for each sequence using McNemar test. A subgroup analysis was conducted for HCCs. Image artifacts were analyzed and compared using Wilcoxon paired signed rank-test. Thirty-three patients were included: 13 patients had 40 hepatocellular carcinomas (HCC) and 20 had 54 liver metastases. 3D-T2-weighted sequences had a higher sensitivity than T2-weighted TSE sequences for the detection of malignant liver tumors (79.8% versus 68.1%; P < 0.001). The difference did not reach significance for HCC. T1-weighted VIBE and DWI had a higher sensitivity than T2-weighted sequences. 3D-T2-weighted-SPACE sequences showed significantly less artifacts than T2-weitghted TSE. 3D-T2-weighted sequences show very promising performances for the detection of liver malignant tumors compared to T2-weighted TSE sequences. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Acoustic noise reduction in T 1- and proton-density-weighted turbo spin-echo imaging.

    PubMed

    Ott, Martin; Blaimer, Martin; Breuer, Felix; Grodzki, David; Heismann, Björn; Jakob, Peter

    2016-02-01

    To reduce acoustic noise levels in T 1-weighted and proton-density-weighted turbo spin-echo (TSE) sequences, which typically reach acoustic noise levels up to 100 dB(A) in clinical practice. Five acoustic noise reduction strategies were combined: (1) gradient ramps and shapes were changed from trapezoidal to triangular, (2) variable-encoding-time imaging was implemented to relax the phase-encoding gradient timing, (3) RF pulses were adapted to avoid the need for reversing the polarity of the slice-rewinding gradient, (4) readout bandwidth was increased to provide more time for gradient activity on other axes, (5) the number of slices per TR was reduced to limit the total gradient activity per unit time. We evaluated the influence of each measure on the acoustic noise level, and conducted in vivo measurements on a healthy volunteer. Sound recordings were taken for comparison. An overall acoustic noise reduction of up to 16.8 dB(A) was obtained by the proposed strategies (1-4) and the acquisition of half the number of slices per TR only. Image quality in terms of SNR and CNR was found to be preserved. The proposed measures in this study allowed a threefold reduction in the acoustic perception of T 1-weighted and proton-density-weighted TSE sequences compared to a standard TSE-acquisition. This could be achieved without visible degradation of image quality, showing the potential to improve patient comfort and scan acceptability.

  1. [Imaging characteristics of PROPELLER T2-weighted imaging].

    PubMed

    Goto, Masami; Aoki, Shigeki; Hayashi, Naoto; Mori, Harushi; Watanabe, Yasushi; Ino, Kenji; Satake, Yoshirou; Nishida, Katuji; Sato, Haruo; Iida, Kyouhito; Mima, Kazuo; Ohtomo, Kuni

    2004-11-01

    As the PROPELLER sequence is a combination of the radial scan and fast-spin-echo (FSE) sequence, it can be considered an FSE sequence with a motion correlation. However, there are some differences between PROPELLER and FSE owing to differences in k-space trajectory. We clarified the imaging characteristics of PROPELLER T2-weighted imaging (T2WI) for different parameters in comparison with usual FSE T2WI. When the same parameters were used, PROPELLER T2WI showed a higher signal-to-noise ratio (SNR) and lower spatial resolution than usual FSE. Effective echo time (TE) changed with different echo train lengths (ETL) or different bandwidths on PROPELLER, and imaging contrast changed accordingly to be more effective.

  2. 3D T2-weighted imaging to shorten multiparametric prostate MRI protocols.

    PubMed

    Polanec, Stephan H; Lazar, Mathias; Wengert, Georg J; Bickel, Hubert; Spick, Claudio; Susani, Martin; Shariat, Shahrokh; Clauser, Paola; Baltzer, Pascal A T

    2018-04-01

    To determine whether 3D acquisitions provide equivalent image quality, lesion delineation quality and PI-RADS v2 performance compared to 2D acquisitions in T2-weighted imaging of the prostate at 3 T. This IRB-approved, prospective study included 150 consecutive patients (mean age 63.7 years, 35-84 years; mean PSA 7.2 ng/ml, 0.4-31.1 ng/ml). Two uroradiologists (R1, R2) independently rated image quality and lesion delineation quality using a five-point ordinal scale and assigned a PI-RADS score for 2D and 3D T2-weighted image data sets. Data were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. Image quality was similarly good to excellent for 2D T2w (mean score R1, 4.3 ± 0.81; R2, 4.7 ± 0.83) and 3D T2w (mean score R1, 4.3 ± 0.82; R2, 4.7 ± 0.69), p = 0.269. Lesion delineation was rated good to excellent for 2D (mean score R1, 4.16 ± 0.81; R2, 4.19 ± 0.92) and 3D T2w (R1, 4.19 ± 0.94; R2, 4.27 ± 0.94) without significant differences (p = 0.785). ROC analysis showed an equivalent performance for 2D (AUC 0.580-0.623) and 3D (AUC 0.576-0.629) T2w (p > 0.05, respectively). Three-dimensional acquisitions demonstrated equivalent image and lesion delineation quality, and PI-RADS v2 performance, compared to 2D in T2-weighted imaging of the prostate. Three-dimensional T2-weighted imaging could be used to considerably shorten prostate MRI protocols in clinical practice. • 3D shows equivalent image quality and lesion delineation compared to 2D T2w. • 3D T2w and 2D T2w image acquisition demonstrated comparable diagnostic performance. • Using a single 3D T2w acquisition may shorten the protocol by 40%. • Combined with short DCE, multiparametric protocols of 10 min are feasible.

  3. Contrast-enhanced Magnetic Resonance Imaging of Pelvic Bone Metastases at 3.0 T: Comparison Between 3-dimensional T1-weighted CAIPIRINHA-VIBE Sequence and 2-dimensional T1-weighted Turbo Spin-Echo Sequence.

    PubMed

    Yoon, Min A; Hong, Suk-Joo; Lee, Kyu-Chong; Lee, Chang Hee

    2018-06-12

    This study aimed to compare 3-dimensional T1-weighted gradient-echo sequence (CAIPIRINHA-volumetric interpolated breath-hold examination [VIBE]) with 2-dimensional T1-weighted turbo spin-echo sequence for contrast-enhanced magnetic resonance imaging (MRI) of pelvic bone metastases at 3.0 T. Thirty-one contrast-enhanced MRIs of pelvic bone metastases were included. Two contrast-enhanced sequences were evaluated for the following parameters: overall image quality, sharpness of pelvic bone, iliac vessel clarity, artifact severity, and conspicuity and edge sharpness of the smallest metastases. Quantitative analysis was performed by calculating signal-to-noise ratio and contrast-to-noise ratio of the smallest metastases. Significant differences between the 2 sequences were assessed. CAIPIRINHA-VIBE had higher scores for overall image quality, pelvic bone sharpness, iliac vessel clarity, and edge sharpness of the metastatic lesions, and had less artifacts (all P < 0.05). There was no significant difference in conspicuity, signal-to-noise ratio, or contrast-to-noise ratio of the smallest metastases (P > 0.05). Our results suggest that CAIPIRINHA-VIBE may be superior to turbo spin-echo for contrast-enhanced MRI of pelvic bone metastases at 3.0 T.

  4. T1- or T2-weighted magnetic resonance imaging: what is the best choice to evaluate atrophy of the hippocampus?

    PubMed

    Fischbach-Boulanger, C; Fitsiori, A; Noblet, V; Baloglu, S; Oesterle, H; Draghici, S; Philippi, N; Duron, E; Hanon, O; Dietemann, J-L; Blanc, F; Kremer, S

    2018-05-01

    Magnetic resonance imaging is part of the diagnostic criteria for Alzheimer's disease (AD) through the evaluation of hippocampal atrophy. The objective of this study was to evaluate which sequence of T1-weighted (T1WI) and T2-weighted (T2WI) imaging allowed the best visual evaluation of hippocampal atrophy. Visual qualitative ratings of the hippocampus of 100 patients with mild cognitive impairment (MCI) and 50 patients with AD were made independently by four operators according to the medial temporal lobe atrophy score based either on T1WI or T2WI. These two evaluations were compared in terms of interobserver reproducibility, concordance with a quantitative volumetric measure, discrimination power between AD and MCI groups, and correlation with several neuropsychological tests. The medial temporal lobe atrophy score evaluated on either T1WI or T2WI exhibited similar interobserver variability and accordance with quantitative volumetric evaluation. However, the visual evaluation on T2WI seemed to provide better discrimination power between AD and MCI groups for both left (T1WI, P = 0.0001; T2WI, P = 7.072 × 10 -5 ) and right (T1WI, P = 0.008; T2WI, P = 0.001) hippocampus, and a higher overall correlation with neuropsychological tests. The present study suggests that T2WI provides a more adequate visual rating of hippocampal atrophy. © 2018 EAN.

  5. Whole brain myelin mapping using T1- and T2-weighted MR imaging data

    PubMed Central

    Ganzetti, Marco; Wenderoth, Nicole; Mantini, Dante

    2014-01-01

    Despite recent advancements in MR imaging, non-invasive mapping of myelin in the brain still remains an open issue. Here we attempted to provide a potential solution. Specifically, we developed a processing workflow based on T1-w and T2-w MR data to generate an optimized myelin enhanced contrast image. The workflow allows whole brain mapping using the T1-w/T2-w technique, which was originally introduced as a non-invasive method for assessing cortical myelin content. The hallmark of our approach is a retrospective calibration algorithm, applied to bias-corrected T1-w and T2-w images, that relies on image intensities outside the brain. This permits standardizing the intensity histogram of the ratio image, thereby allowing for across-subject statistical analyses. Quantitative comparisons of image histograms within and across different datasets confirmed the effectiveness of our normalization procedure. Not only did the calibrated T1-w/T2-w images exhibit a comparable intensity range, but also the shape of the intensity histograms was largely corresponding. We also assessed the reliability and specificity of the ratio image compared to other MR-based techniques, such as magnetization transfer ratio (MTR), fractional anisotropy (FA), and fluid-attenuated inversion recovery (FLAIR). With respect to these other techniques, T1-w/T2-w had consistently high values, as well as low inter-subject variability, in brain structures where myelin is most abundant. Overall, our results suggested that the T1-w/T2-w technique may be a valid tool supporting the non-invasive mapping of myelin in the brain. Therefore, it might find important applications in the study of brain development, aging and disease. PMID:25228871

  6. T1 vs. T2 weighted magnetic resonance imaging to assess total kidney volume in patients with autosomal dominant polycystic kidney disease.

    PubMed

    van Gastel, Maatje D A; Messchendorp, A Lianne; Kappert, Peter; Kaatee, Merel A; de Jong, Marissa; Renken, Remco J; Ter Horst, Gert J; Mahesh, Shekar V K; Gansevoort, Ron T

    2018-05-01

    In ADPKD patients total kidney volume (TKV) measurement using MRI is performed to predict rate of disease progression. Historically T1 weighted images (T1) were used, but the methodology of T2 weighted imaging (T2) has evolved. We compared the performance of both sequences. 40 ADPKD patients underwent an abdominal MRI at baseline and follow-up. TKV was measured by manual tracing with Analyze Direct 11.0 software. Three readers established intra- and interreader coefficients of variation (CV). T1 and T2 measured kidney volumes and growth rates were compared with ICC and Bland-Altman analyses. Participants were 49.7 ± 7.0 years of age, 55.0% female, with estimated GFR of 50.1 ± 11.5 mL/min/1.73 m 2 . CVs were low and comparable for T2 and T1 (intrareader: 0.83% [0.48-1.79] vs. 1.15% [0.34-1.77], P = 0.9, interreader: 2.18% [1.59-2.61] vs. 1.69% [1.07-3.87], P = 0.9). TKV was clinically similar, but statistically significantly different between T2 and T1: 1867 [1172-2721] vs. 1932 [1180-2551] mL, respectively (P = 0.006), with a bias of only 0.8% and high agreement (ICC 0.997). Percentage kidney growth during 2.2 ± 0.3 years was similar for T2 and T1 (9.3 ± 10.6% vs. 7.8 ± 9.9%, P = 0.1, respectively), with a bias of 1.5% and high agreement (ICC 0.843). T2 was more often of sufficient quality for volume measurement (86.7% vs. 71.1%, P < 0.001). In patients with ADPKD, measurement of kidney volume and growth rate performs similarly when using T2 compared to T1 weighted images, although T2 performs better on secondary outcome parameters; they are more often of sufficient quality for volume measurement and result in slightly lower intra- and interreader variability.

  7. Diagnostic value of T1-weighted gradient-echo in-phase images added to MRCP in differentiation of hepatolithiasis and intrahepatic pneumobilia.

    PubMed

    Erden, Ayşe; Haliloğlu, Nuray; Genç, Yasemin; Erden, Ilhan

    2014-01-01

    The purpose of this article is to determine the added diagnostic value of T1-weighted gradient-echo in-phase images obtained during MRCP in the detection and differentiation of hepatolithiasis and intrahepatic pneumobilia. Intrahepatic bile ducts in 47 patients were scored in terms of their possibility of containing biliary stone and air. MRI was performed with a 1-T system for 32 patients and with a 3-T system for 15 patients. Two radiologists independently reviewed two sets of MRI scans: set 1 included T2-weighted MRCP images, and set 2 included T2-weighted MRCP images plus T1-weighted gradient-echo in-phase images. The diagnostic performances of set 1 and set 2 in the evaluation of the bile ducts containing air or stone and bile ducts containing neither of them were analyzed using the area under the receiver operating characteristic curve (AUC) for clustered data. The sensitivities and specificities of both image sets to detect intrahepatic stone or air were also calculated and compared. For the diagnosis of hepatolithiasis, the AUC obtained from set 2 (0.983) was significantly higher than that obtained from set 1 (0.879; p = 0.037). For the diagnosis of pneumobilia, the AUC obtained from set 2 (0.965) was also significantly higher than that of set 1 (0.765; p = 0.002). With use of percutaneous transhepatic cholangiography, ERCP, and CT as the reference standards, the sensitivity of set 2 (97.1%; 95% CI, 91.1-100%) was significantly higher than that of set 1 (74.3%; 95% CI, 56.7-91.9%) in detecting intrahepatic stones (p = 0.011). For the detection of pneumobilia, the sensitivity of set 2 (98.5%; 95% CI, 95.4-100%) was also significantly higher than that of set 1 (70.8%; 95% CI, 57.7-83.3%; p = 0.000). The addition of T1-weighted gradient-echo in-phase images to standard MRCP sequences improves the detection and differentiation of hepatolithiasis and intrahepatic pneumobilia.

  8. T1-weighted brain imaging with a 32-channel coil at 3T using TurboFLASH BLADE compared with standard cartesian k-space sampling.

    PubMed

    Attenberger, Ulrike I; Runge, Val M; Williams, Kenneth D; Stemmer, Alto; Michaely, Henrik J; Schoenberg, Stefan O; Reiser, Maximilian F; Wintersperger, Bernd J

    2009-03-01

    Motion artifacts often markedly degrade image quality in clinical scans. The BLADE technique offers an alternative k-space sampling scheme reducing the effect of patient related motion on image quality. The purpose of this study is the comparison of imaging artifacts, signal-to-noise (SNR), and contrast-to-noise ratio (CNR) of a new turboFLASH BLADE k-space trajectory with the standard Cartesian k-space sampling for brain imaging, using a 32-channel coil at 3T. The results from 32 patients included after informed consent are reported. This study was performed with a 32-channel head coil on a 3T scanner. Sagittal and axial T1-weighted FLASH sequences (TR/TE 250/2.46 milliseconds, flip angle 70-degree), acquired with Cartesian k-space sampling and T1-weighted turboFLASH sequences (TR/TE/TIsag/TIax 3200/2.77/1144/1056 milliseconds, flip angle 20-degree), using PROPELLER (BLADE) k-space trajectory, were compared. SNR and CNR were evaluated using a paired student t test. The frequency of motion artifacts was assessed in a blinded read. To analyze the differences between both techniques a McNemar test was performed. A P value <0.05 was considered statistically significant. From the blinded read, the overall preference in terms of diagnostic image quality was statistically significant in favor of the BLADE turboFLASH data sets, compared with standard FLASH for both sagittal (P < 0.0001) and axial (P < 0.0001) planes. The frequency of motion artifacts from the scalp was higher for standard FLASH sequences than for BLADE sequences on both axial (47%, P < 0.0003) and sagittal (69%, P < 0.0001) planes. BLADE was preferred in 100% (sagittal plane) and 80% (axial plane) of in-patient data sets and in 68% (sagittal plane) and 73% (axial plane) of out-patient data sets.The BLADE T1 scan did have lower SNRmean (BLADEax 179 +/- 98, Cartesianax 475 +/- 145, BLADEsag 171 +/- 51, and Cartesiansag 697 +/- 129) with P values indicating accordingly a statistically significant difference

  9. Ultrasmall water-soluble metal-iron oxide nanoparticles as T1-weighted contrast agents for magnetic resonance imaging.

    PubMed

    Zeng, Leyong; Ren, Wenzhi; Zheng, Jianjun; Cui, Ping; Wu, Aiguo

    2012-02-28

    Using an improved hydrolysis method of inorganic salts assisted with water-bath incubation, ultrasmall water-soluble metal-iron oxide nanoparticles (including Fe(3)O(4), ZnFe(2)O(4) and NiFe(2)O(4) nanoparticles) were synthesized in aqueous solutions, which were used as T(1)-weighted contrast agents for magnetic resonance imaging (MRI). The morphology, structure, MRI relaxation properties and cytotoxicity of the as-prepared metal-iron oxide nanoparticles were characterized, respectively. The results showed that the average sizes of nanoparticles were about 4 nm, 4 nm and 5 nm for Fe(3)O(4), ZnFe(2)O(4) and NiFe(2)O(4) nanoparticles, respectively. Moreover, the nanoparticles have good water dispersibility and low cytotoxicity. The MRI test showed the strong T(1)-weighted, but the weak T(2)-weighted MRI performance of metal-iron oxide nanoparticles. The high T(1)-weighted MRI performance can be attributed to the ultrasmall size of metal-iron oxide nanoparticles. Therefore, the as-prepared metal-iron oxide nanoparticles with good water dispersibility and ultrasmall size can have potential applications as T(1)-weighted contrast agent materials for MRI.

  10. RGD-functionalized ultrasmall iron oxide nanoparticles for targeted T1-weighted MR imaging of gliomas

    NASA Astrophysics Data System (ADS)

    Luo, Yu; Yang, Jia; Yan, Yu; Li, Jingchao; Shen, Mingwu; Zhang, Guixiang; Mignani, Serge; Shi, Xiangyang

    2015-08-01

    We report a convenient approach to prepare ultrasmall Fe3O4 nanoparticles (NPs) functionalized with an arginylglycylaspartic acid (RGD) peptide for in vitro and in vivo magnetic resonance (MR) imaging of gliomas. In our work, stable sodium citrate-stabilized Fe3O4 NPs were prepared by a solvothermal route. Then, the carboxylated Fe3O4 NPs stabilized with sodium citrate were conjugated with polyethylene glycol (PEG)-linked RGD. The formed ultrasmall RGD-functionalized nanoprobe (Fe3O4-PEG-RGD) was fully characterized using different techniques. We show that these Fe3O4-PEG-RGD particles with a size of 2.7 nm are water-dispersible, stable, cytocompatible and hemocompatible in a given concentration range, and display targeting specificity to glioma cells overexpressing αvβ3 integrin in vitro. With the relatively high r1 relaxivity (r1 = 1.4 mM-1 s-1), the Fe3O4-PEG-RGD particles can be used as an efficient nanoprobe for targeted T1-weighted positive MR imaging of glioma cells in vitro and the xenografted tumor model in vivo via an active RGD-mediated targeting pathway. The developed RGD-functionalized Fe3O4 NPs may hold great promise to be used as a nanoprobe for targeted T1-weighted MR imaging of different αvβ3 integrin-overexpressing cancer cells or biological systems.We report a convenient approach to prepare ultrasmall Fe3O4 nanoparticles (NPs) functionalized with an arginylglycylaspartic acid (RGD) peptide for in vitro and in vivo magnetic resonance (MR) imaging of gliomas. In our work, stable sodium citrate-stabilized Fe3O4 NPs were prepared by a solvothermal route. Then, the carboxylated Fe3O4 NPs stabilized with sodium citrate were conjugated with polyethylene glycol (PEG)-linked RGD. The formed ultrasmall RGD-functionalized nanoprobe (Fe3O4-PEG-RGD) was fully characterized using different techniques. We show that these Fe3O4-PEG-RGD particles with a size of 2.7 nm are water-dispersible, stable, cytocompatible and hemocompatible in a given concentration

  11. Assessment of cerebral venous sinus thrombosis using T2*-weighted gradient echo magnetic resonance imaging sequences

    PubMed Central

    Bidar, Fatemeh; Faeghi, Fariborz; Ghorbani, Askar

    2016-01-01

    Background: The purpose of this study is to demonstrate the advantages of gradient echo (GRE) sequences in the detection and characterization of cerebral venous sinus thrombosis compared to conventional magnetic resonance sequences. Methods: A total of 17 patients with cerebral venous thrombosis (CVT) were evaluated using different magnetic resonance imaging (MRI) sequences. The MRI sequences included T1-weighted spin echo (SE) imaging, T*2-weighted turbo SE (TSE), fluid attenuated inversion recovery (FLAIR), T*2-weighted conventional GRE, and diffusion weighted imaging (DWI). MR venography (MRV) images were obtained as the golden standard. Results: Venous sinus thrombosis was best detectable in T*2-weighted conventional GRE sequences in all patients except in one case. Venous thrombosis was undetectable in DWI. T*2-weighted GRE sequences were superior to T*2-weighted TSE, T1-weighted SE, and FLAIR. Enhanced MRV was successful in displaying the location of thrombosis. Conclusion: T*2-weighted conventional GRE sequences are probably the best method for the assessment of cerebral venous sinus thrombosis. The mentioned method is non-invasive; therefore, it can be employed in the clinical evaluation of cerebral venous sinus thrombosis. PMID:27326365

  12. On the fallacy of quantitative segmentation for T1-weighted MRI

    NASA Astrophysics Data System (ADS)

    Plassard, Andrew J.; Harrigan, Robert L.; Newton, Allen T.; Rane, Swati; Pallavaram, Srivatsan; D'Haese, Pierre F.; Dawant, Benoit M.; Claassen, Daniel O.; Landman, Bennett A.

    2016-03-01

    T1-weighted magnetic resonance imaging (MRI) generates contrasts with primary sensitivity to local T1 properties (with lesser T2 and PD contributions). The observed signal intensity is determined by these local properties and the sequence parameters of the acquisition. In common practice, a range of acceptable parameters is used to ensure "similar" contrast across scanners used for any particular study (e.g., the ADNI standard MPRAGE). However, different studies may use different ranges of parameters and report the derived data as simply "T1-weighted". Physics and imaging authors pay strong heed to the specifics of the imaging sequences, but image processing authors have historically been more lax. Herein, we consider three T1-weighted sequences acquired the same underlying protocol (MPRAGE) and vendor (Philips), but "normal study-to-study variation" in parameters. We show that the gray matter/white matter/cerebrospinal fluid contrast is subtly but systemically different between these images and yields systemically different measurements of brain volume. The problem derives from the visually apparent boundary shifts, which would also be seen by a human rater. We present and evaluate two solutions to produce consistent segmentation results across imaging protocols. First, we propose to acquire multiple sequences on a subset of the data and use the multi-modal imaging as atlases to segment target images any of the available sequences. Second (if additional imaging is not available), we propose to synthesize atlases of the target imaging sequence and use the synthesized atlases in place of atlas imaging data. Both approaches significantly improve consistency of target labeling.

  13. T2-weighted images are superior to other MR image types for the determination of diffuse intrinsic pontine glioma intratumoral heterogeneity.

    PubMed

    Harward, Stephen; Harrison Farber, S; Malinzak, Michael; Becher, Oren; Thompson, Eric M

    2018-03-01

    Diffuse intrinsic pontine glioma (DIPG) remains the main cause of death in children with brain tumors. Given the inefficacy of numerous peripherally delivered agents to treat DIPG, convection enhanced delivery (CED) of therapeutic agents is a promising treatment modality. The purpose of this study was to determine which MR imaging type provides the best discrimination of intratumoral heterogeneity to guide future stereotactic implantation of CED catheters into the most cellular tumor regions. Patients ages 18 years or younger with a diagnosis of DIPG from 2000 to 2015 were included. Radiographic heterogeneity index (HI) of the tumor was calculated by measuring the standard deviation of signal intensity of the tumor (SD Tumor ) normalized to the genu of the corpus callosum (SD Corpus Callosum ). Four MR image types (T2-weighted, contrast-enhanced T1-weighted, FLAIR, and ADC) were analyzed at several time points both before and after radiotherapy and chemotherapy. HI values across these MR image types were compared and correlated with patient survival. MR images from 18 patients with DIPG were evaluated. The mean survival ± standard deviation was 13.8 ± 13.7 months. T2-weighted images had the highest HI (mean ± SD, 5.1 ± 2.5) followed by contrast-enhanced T1-weighted images (3.7 ± 1.5), FLAIR images (3.0 ± 1.1), and ADC maps (1.6 ± 0.4). ANOVA demonstrated that HI values were significantly higher for T2-weighted images than FLAIR (p < 0.01) and ADC (p < 0.0001). Following radiotherapy, T2-weighted and contrast-enhanced T1-weighted image HI values increased, while FLAIR and ADC HI values decreased. Univariate and multivariate analyses did not reveal a relationship between HI values and patient survival (p > 0.05). For children with DIPG, T2-weighted MRI demonstrates the greatest signal intensity variance suggesting tumor heterogeneity. Within this heterogeneity, T2-weighted signal hypointensity is known to correlate with

  14. T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

    PubMed

    Van de Moortele, Pierre-François; Auerbach, Edwards J; Olman, Cheryl; Yacoub, Essa; Uğurbil, Kâmil; Moeller, Steen

    2009-06-01

    At high magnetic field, MR images exhibit large, undesirable signal intensity variations commonly referred to as "intensity field bias". Such inhomogeneities mostly originate from heterogeneous RF coil B(1) profiles and, with no appropriate correction, are further pronounced when utilizing rooted sum of square reconstruction with receive coil arrays. These artifacts can significantly alter whole brain high resolution T(1)-weighted (T(1)w) images that are extensively utilized for clinical diagnosis, for gray/white matter segmentation as well as for coregistration with functional time series. In T(1) weighted 3D-MPRAGE sequences, it is possible to preserve a bulk amount of T(1) contrast through space by using adiabatic inversion RF pulses that are insensitive to transmit B(1) variations above a minimum threshold. However, large intensity variations persist in the images, which are significantly more difficult to address at very high field where RF coil B(1) profiles become more heterogeneous. Another characteristic of T(1)w MPRAGE sequences is their intrinsic sensitivity to Proton Density and T(2)(*) contrast, which cannot be removed with post-processing algorithms utilized to correct for receive coil sensitivity. In this paper, we demonstrate a simple technique capable of producing normalized, high resolution T(1)w 3D-MPRAGE images that are devoid of receive coil sensitivity, Proton Density and T(2)(*) contrast. These images, which are suitable for routinely obtaining whole brain tissue segmentation at 7 T, provide higher T(1) contrast specificity than standard MPRAGE acquisitions. Our results show that removing the Proton Density component can help in identifying small brain structures and that T(2)(*) induced artifacts can be removed from the images. The resulting unbiased T(1)w images can also be used to generate Maximum Intensity Projection angiograms, without additional data acquisition, that are inherently registered with T(1)w structural images. In addition

  15. T1 weighted Brain Images at 7 Tesla Unbiased for Proton Density, T2* contrast and RF Coil Receive B1 Sensitivity with Simultaneous Vessel Visualization

    PubMed Central

    Van de Moortele, Pierre-François; Auerbach, Edwards J.; Olman, Cheryl; Yacoub, Essa; Uğurbil, Kâmil; Moeller, Steen

    2009-01-01

    At high magnetic field, MR images exhibit large, undesirable signal intensity variations commonly referred to as “intensity field bias”. Such inhomogeneities mostly originate from heterogeneous RF coil B1 profiles and, with no appropriate correction, are further pronounced when utilizing rooted sum of square reconstruction with receive coil arrays. These artifacts can significantly alter whole brain high resolution T1-weighted (T1w) images that are extensively utilized for clinical diagnosis, for gray/white matter segmentation as well as for coregistration with functional time series. In T1 weighted 3D-MPRAGE sequences, it is possible to preserve a bulk amount of T1 contrast through space by using adiabatic inversion RF pulses that are insensitive to transmit B1 variations above a minimum threshold. However, large intensity variations persist in the images, which are significantly more difficult to address at very high field where RF coil B1 profiles become more heterogeneous. Another characteristic of T1w MPRAGE sequences is their intrinsic sensitivity to Proton Density and T2* contrast, which cannot be removed with post-processing algorithms utilized to correct for receive coil sensitivity. In this paper, we demonstrate a simple technique capable of producing normalized, high resolution T1w 3D-MPRAGE images that are devoid of receive coil sensitivity, Proton Density and T2* contrast. These images, which are suitable for routinely obtaining whole brain tissue segmentation at 7 Tesla, provide higher T1 contrast specificity than standard MPRAGE acquisitions. Our results show that removing the Proton Density component can help identifying small brain structures and that T2* induced artifacts can be removed from the images. The resulting unbiased T1w images can also be used to generate Maximum Intensity Projection angiograms, without additional data acquisition, that are inherently registered with T1w structural images. In addition, we introduce a simple technique

  16. Whole-brain intracranial vessel wall imaging at 3 Tesla using cerebrospinal fluid-attenuated T1-weighted 3D turbo spin echo.

    PubMed

    Fan, Zhaoyang; Yang, Qi; Deng, Zixin; Li, Yuxia; Bi, Xiaoming; Song, Shlee; Li, Debiao

    2017-03-01

    Although three-dimensional (3D) turbo spin echo (TSE) with variable flip angles has proven to be useful for intracranial vessel wall imaging, it is associated with inadequate suppression of cerebrospinal fluid (CSF) signals and limited spatial coverage at 3 Tesla (T). This work aimed to modify the sequence and develop a protocol to achieve whole-brain, CSF-attenuated T 1 -weighted vessel wall imaging. Nonselective excitation and a flip-down radiofrequency pulse module were incorporated into a commercial 3D TSE sequence. A protocol based on the sequence was designed to achieve T 1 -weighted vessel wall imaging with whole-brain spatial coverage, enhanced CSF-signal suppression, and isotropic 0.5-mm resolution. Human volunteer and pilot patient studies were performed to qualitatively and quantitatively demonstrate the advantages of the sequence. Compared with the original sequence, the modified sequence significantly improved the T 1 -weighted image contrast score (2.07 ± 0.19 versus 3.00 ± 0.00, P = 0.011), vessel wall-to-CSF contrast ratio (0.14 ± 0.16 versus 0.52 ± 0.30, P = 0.007) and contrast-to-noise ratio (1.69 ± 2.18 versus 4.26 ± 2.30, P = 0.022). Significant improvement in vessel wall outer boundary sharpness was observed in several major arterial segments. The new 3D TSE sequence allows for high-quality T 1 -weighted intracranial vessel wall imaging at 3 T. It may potentially aid in depicting small arteries and revealing T 1 -mediated high-signal wall abnormalities. Magn Reson Med 77:1142-1150, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  17. Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference.

    PubMed

    Wagner, Mathilde; Maggiori, Léon; Ronot, Maxime; Paradis, Valérie; Vilgrain, Valérie; Panis, Yves; Van Beers, Bernard E

    2013-08-01

    To compare diffusion-weighted (DW) and T2-weighted MR imaging in detecting colorectal liver metastases in a rat model, using histological examination as a reference method. Eighteen rats had four liver injections of colon cancer cells. MR examinations at 7 T included FSE-T2-weighted imaging and SE-DW MR imaging (b = 0, 20 and 150 s/mm(2)) and were analysed by two independent readers. Histological examination was performed on 0.4-mm slices. McNemar's test was used to compare the sensitivities and the Wilcoxon matched pairs test to compare the average number of false-positives per rat. One hundred and sixty-six liver metastases were identified on histological examination. The sensitivity in detecting liver metastases was significantly higher on DW MR than on T2-weighted images (99/166 (60 %) (reader 1) and 92/166 (55 %) (reader 2) versus 77/166 (46 %), P ≤ 0.001), without an increase in false-positives per rat (P = 0.773/P = 0.850). After stratification according to metastasis diameter, DW MR imaging had a significantly higher sensitivity than T2-weighted imaging only for metastases with a diameter (0.6-1.2 mm) similar to that of the spatial resolution of MR imaging in the current study. This MR study with histological correlations shows the higher sensitivity of DW relative to T2-weighted imaging at 7 T for detecting liver metastases, especially small ones. • Diffusion weighted (DW) sequences are increasingly used in magnetic resonance imaging (MRI). • DW has higher sensitivity for liver metastases than T2-weighted imaging at 7 T. • This increase in sensitivity is especially marked for small liver metastasis detection. • This higher sensitivity is confirmed in an animal model with histological correlation. • DW imaging has the potential for earlier diagnosis of small liver metastases.

  18. Normalization of white matter intensity on T1-weighted images of patients with acquired central nervous system demyelination.

    PubMed

    Ghassemi, Rezwan; Brown, Robert; Narayanan, Sridar; Banwell, Brenda; Nakamura, Kunio; Arnold, Douglas L

    2015-01-01

    Intensity variation between magnetic resonance images (MRI) hinders comparison of tissue intensity distributions in multicenter MRI studies of brain diseases. The available intensity normalization techniques generally work well in healthy subjects but not in the presence of pathologies that affect tissue intensity. One such disease is multiple sclerosis (MS), which is associated with lesions that prominently affect white matter (WM). To develop a T1-weighted (T1w) image intensity normalization method that is independent of WM intensity, and to quantitatively evaluate its performance. We calculated median intensity of grey matter and intraconal orbital fat on T1w images. Using these two reference tissue intensities we calculated a linear normalization function and applied this to the T1w images to produce normalized T1w (NT1) images. We assessed performance of our normalization method for interscanner, interprotocol, and longitudinal normalization variability, and calculated the utility of the normalization method for lesion analyses in clinical trials. Statistical modeling showed marked decreases in T1w intensity differences after normalization (P < .0001). We developed a WM-independent T1w MRI normalization method and tested its performance. This method is suitable for longitudinal multicenter clinical studies for the assessment of the recovery or progression of disease affecting WM. Copyright © 2014 by the American Society of Neuroimaging.

  19. The image evaluation of iterative motion correction reconstruction algorithm PROPELLER T2-weighted imaging compared with MultiVane T2-weighted imaging

    NASA Astrophysics Data System (ADS)

    Lee, Suk-Jun; Yu, Seung-Man

    2017-08-01

    The purpose of this study was to evaluate the usefulness and clinical applications of MultiVaneXD which was applying iterative motion correction reconstruction algorithm T2-weighted images compared with MultiVane images taken with a 3T MRI. A total of 20 patients with suspected pathologies of the liver and pancreatic-biliary system based on clinical and laboratory findings underwent upper abdominal MRI, acquired using the MultiVane and MultiVaneXD techniques. Two reviewers analyzed the MultiVane and MultiVaneXD T2-weighted images qualitatively and quantitatively. Each reviewer evaluated vessel conspicuity by observing motion artifacts and the sharpness of the portal vein, hepatic vein, and upper organs. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated by one reviewer for quantitative analysis. The interclass correlation coefficient was evaluated to measure inter-observer reliability. There were significant differences between MultiVane and MultiVaneXD in motion artifact evaluation. Furthermore, MultiVane was given a better score than MultiVaneXD in abdominal organ sharpness and vessel conspicuity, but the difference was insignificant. The reliability coefficient values were over 0.8 in every evaluation. MultiVaneXD (2.12) showed a higher value than did MultiVane (1.98), but the difference was insignificant ( p = 0.135). MultiVaneXD is a motion correction method that is more advanced than MultiVane, and it produced an increased SNR, resulting in a greater ability to detect focal abdominal lesions.

  20. Comparison of axial T1 spin-echo and T1 fat-saturation magnetic resonance imaging techniques in the diagnosis of chondromalacia patellae.

    PubMed

    Vanarthos, W J; Pope, T L; Monu, J U

    1994-12-01

    To test the diagnostic value of T1 spin-echo and T1 fat-saturated magnetic resonance images (MRIs), we reviewed axial T1-weighted images with and without fat saturation in 20 patients with clinically suspected chondromalacia of the patella. All scans were obtained on 1.5-MR units. The scans were randomly ordered and reviewed independently at different times by two radiologists without knowledge of the arthroscopy results. The sensitivity of the individual techniques for detecting grade 3 or 4 chondromalacia patellae was 92% for fat-saturated axial T1-weighted images alone, and 67% for axial T1-weighted images without fat saturation. The sensitivity of the combined techniques was 100% for grades 3 and 4 and 90% for all grades (0 to 4). Chondromalacia patellae is diagnosed more accurately by using T1 fat saturation than by using T1 spin-echo images. With a combination of the two techniques, accuracy is 90% to 100%.

  1. Abdominal MRI at 3.0 T: LAVA-Flex compared with conventional fat suppression T1-weighted images.

    PubMed

    Li, Xing Hui; Zhu, Jiang; Zhang, Xiao Ming; Ji, Yi Fan; Chen, Tian Wu; Huang, Xiao Hua; Yang, Lin; Zeng, Nan Lin

    2014-07-01

    To study liver imaging with volume acceleration-flexible (LAVA-Flex) for abdominal magnetic resonance imaging (MRI) at 3.0 T and compare the image quality of abdominal organs between LAVA-Flex and fast spoiled gradient-recalled (FSPGR) T1-weighted imaging. Our Institutional Review Board approval was obtained in this retrospective study. Sixty-nine subjects had both FSPGR and LAVA-Flex sequences. Two radiologists independently scored the acquisitions for image quality, fat suppression quality, and artifacts and the values obtained were compared with the Wilcoxon signed rank test. According to the signal intensity (SI) measurements, the uniformity of fat suppression, the contrast between muscle and fat and normal liver and liver lesions were compared by the paired t-test. The liver and spleen SI on the fat-only phase were analyzed in the fatty liver patients. Compared with FSPGR imaging, LAVA-Flex images had better and more homogenous fat suppression and lower susceptibility artifact (qualitative scores: 4.70 vs. 4.00, 4.86% vs. 7.14%, 4.60 and 4.10, respectively). The contrast between muscle and fat and between the liver and pathologic lesions was significantly improved on the LAVA-Flex sequence. The contrast value of the fatty liver and spleen was higher than that of the liver and spleen. The LAVA-Flex sequence offers superior and more homogenous fat suppression of the abdomen than does the FSPGR sequence. The fat-only phase can be a simple and effective method of assessing fatty liver. © 2013 Wiley Periodicals, Inc.

  2. Effect of Renal Function on Gadolinium-Related Signal Increases on Unenhanced T1-Weighted Brain Magnetic Resonance Imaging.

    PubMed

    Cao, Yan; Zhang, Yang; Shih, George; Zhang, Yan; Bohmart, Andrew; Hecht, Elizabeth M; Prince, Martin R

    2016-11-01

    The purpose of this study was to determine if renal function affects signal changes in the deep brain nuclei on unenhanced T1-weighted images after administration of linear gadolinium-based contrast agents (GBCAs). An electronic medical records search of 2 large medical centers identified 25 patients who received linear GBCA while on hemodialysis and had unenhanced T1-weighted images of the brain before and after. The dentate-to-cerebellar peduncle (DCP) ratio, globus pallidus-to-mid thalamus (GPT) ratio, and choroid plexus-to-nearby white matter ratio were measured and compared with 25 age/sex/GBCA exposure-matched control patients with normal or near-normal renal function (estimated glomerular filtration rate >60 mL/min per 1.73 m). Two additional control groups included 13 patients on hemodialysis without GBCA exposure and 13 age/sex-matched patients with estimated glomerular filtration rate greater than 60 mL/min per 1.73 m. Hemodialysis patients (n = 25) with an average of 1.8 linear GBCA administrations had a 4.9% mean increase (1.00 ± 0.04 vs 1.05 ± 0.05; P < 0.001) in DCP, which was greater than the 1.6% change (0.99 ± 0.04 vs 1.00 ± 0.05; P = 0.08) observed in matched controls (P = 0.01). There was no significant signal change in the DCP ratio in the 13 hemodialysis patients (0.99 ± 0.04 vs 0.99 ± 0.04; P = 0.78) and 13 age/sex-matched patients (0.99 ± 0.02 vs 0.99 ± 0.03; P = 0.78) who did not receive GBCA. The hemodialysis patients had a baseline GPT that was higher than nondialysis patients (P < 0.001). However, the GPT change after GBCA administration was not significantly different from controls. Increased signal in the choroid plexus on unenhanced T1-weighted images after GBCA administration was noted in hemodialysis patients (0.72 ± 0.20 vs 0.86 ± 0.23; P = 0.006); however, a multivariate analysis showed this to be primarily related to hemodialysis (P = 0.003) with only a trend toward relating to GBCA exposure (P = 0.07). Hemodialysis

  3. Breast MRI at 7 Tesla with a bilateral coil and T1-weighted acquisition with robust fat suppression: image evaluation and comparison with 3 Tesla.

    PubMed

    Brown, Ryan; Storey, Pippa; Geppert, Christian; McGorty, KellyAnne; Leite, Ana Paula Klautau; Babb, James; Sodickson, Daniel K; Wiggins, Graham C; Moy, Linda

    2013-11-01

    To evaluate the image quality of T1-weighted fat-suppressed breast MRI at 7 T and to compare 7-T and 3-T images. Seventeen subjects were imaged using a 7-T bilateral transmit-receive coil and 3D gradient echo sequence with adiabatic inversion-based fat suppression (FS). Images were graded on a five-point scale and quantitatively assessed through signal-to-noise ratio (SNR), fibroglandular/fat contrast and signal uniformity measurements. Image scores at 7 and 3 T were similar on standard-resolution images (1.1 × 1.1 × 1.1-1.6 mm(3)), indicating that high-quality breast imaging with clinical parameters can be performed at 7 T. The 7-T SNR advantage was underscored on 0.6-mm isotropic images, where image quality was significantly greater than at 3 T (4.2 versus 3.1, P ≤ 0.0001). Fibroglandular/fat contrast was more than two times higher at 7 T than at 3 T, owing to effective adiabatic inversion-based FS and the inherent 7-T signal advantage. Signal uniformity was comparable at 7 and 3 T (P < 0.05). Similar 7-T image quality was observed in all subjects, indicating robustness against anatomical variation. The 7-T bilateral transmit-receive coil and adiabatic inversion-based FS technique produce image quality that is as good as or better than at 3 T. • High image quality bilateral breast MRI is achievable with clinical parameters at 7 T. • 7-T high-resolution imaging improves delineation of subtle soft tissue structures. • Adiabatic-based fat suppression provides excellent fibroglandular/fat contrast at 7 T. • 7- and 3-T 3D T1-weighted gradient-echo images have similar signal uniformity. • The 7-T dual solenoid coil enables bilateral imaging without compromising uniformity.

  4. MR of Toxoplasma encephalitis: Signal characteristics on T2-weighted images and pathologic correlation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brightbill, T.C.; Hensley, G.T.; Ruiz, A.

    1996-05-01

    Our goal was to determine if there are any T2-weighted MR signal characteristics of Toxoplasma encephalitis that might be useful in diagnosis and/or in gauging the effectiveness of medical therapy. We retrospectively analyzed the MR, CT, thallium-201 SPECT brain scans, and medical records of 27 patients with medically proven (26) and biopsy proven (1) Toxoplasma encephalitis, supplemented by autopsy findings in 4 additional patients, 2 of whom had postmortem MR correlation. The neuropathologic literature was also reviewed. Among the 27 patients, we discovered three distinct imaging patterns. Ten (37%) patients had predominantly T2-weighted hyperintense lesions and had been on medicalmore » therapy an average of 3 days (excluding one outlier). Ten (37%) patients had T2-weighted isointense lesions and had received medical therapy an average of 61 days. Seven (26%) patients had lesions with mixed signal on T2-weighted images and bad been on treatment an average of 6 days. Analysis of autopsy material from the four additional patients revealed the presence of organizing abscesses in three and necrotizing encephalitis in one, while the patient who had a brain biopsy demonstrated both types of pathologic lesions. In both cases having postmortem MRI, organizing abscesses appeared isointense to hypointense on T2-weighted images. There is a definite variation in the appearance of lesions of Toxoplasma encephalitis on T2-weighted images that precludes a definitive diagnosis based on signal characteristics alone. Pathologically, our data suggest that T2-weighted hyperintensity correlates with necrotizing encephalitis and T2-weighted isointensity with organizing abscesses. Furthermore, in patients on medical therapy the T2-weighted MR appearance may be a transition from hyperintensity to isointensity as a function of a positive response to antibiotic treatment, indicating that the signal change might be used to gauge the effectiveness of medical therapy. 15 refs., 6 figs.« less

  5. High-resolution in vivo Wistar rodent brain atlas based on T1 weighted image

    NASA Astrophysics Data System (ADS)

    Huang, Su; Lu, Zhongkang; Huang, Weimin; Seramani, Sankar; Ramasamy, Boominathan; Sekar, Sakthivel; Guan, Cuntai; Bhakoo, Kishore

    2016-03-01

    Image based atlases for rats brain have a significant impact on pre-clinical research. In this project we acquired T1-weighted images from Wistar rodent brains with fine 59μm isotropical resolution for generation of the atlas template image. By applying post-process procedures using a semi-automatic brain extraction method, we delineated the brain tissues from source data. Furthermore, we applied a symmetric group-wise normalization method to generate an optimized template of T1 image of rodent brain, then aligned our template to the Waxholm Space. In addition, we defined several simple and explicit landmarks to corresponding our template with the well known Paxinos stereotaxic reference system. Anchoring at the origin of the Waxholm Space, we applied piece-wise linear transformation method to map the voxels of the template into the coordinates system in Paxinos' stereotoxic coordinates to facilitate the labelling task. We also cross-referenced our data with both published rodent brain atlas and image atlases available online, methodologically labelling the template to produce a Wistar brain atlas identifying more than 130 structures. Particular attention was paid to the cortex and cerebellum, as these areas encompass the most researched aspects of brain functions. Moreover, we adopted the structure hierarchy and naming nomenclature common to various atlases, so that the names and hierarchy structure presented in the atlas are readily recognised for easy use. It is believed the atlas will present a useful tool in rodent brain functional and pharmaceutical studies.

  6. Deep embedding convolutional neural network for synthesizing CT image from T1-Weighted MR image.

    PubMed

    Xiang, Lei; Wang, Qian; Nie, Dong; Zhang, Lichi; Jin, Xiyao; Qiao, Yu; Shen, Dinggang

    2018-07-01

    Recently, more and more attention is drawn to the field of medical image synthesis across modalities. Among them, the synthesis of computed tomography (CT) image from T1-weighted magnetic resonance (MR) image is of great importance, although the mapping between them is highly complex due to large gaps of appearances of the two modalities. In this work, we aim to tackle this MR-to-CT synthesis task by a novel deep embedding convolutional neural network (DECNN). Specifically, we generate the feature maps from MR images, and then transform these feature maps forward through convolutional layers in the network. We can further compute a tentative CT synthesis from the midway of the flow of feature maps, and then embed this tentative CT synthesis result back to the feature maps. This embedding operation results in better feature maps, which are further transformed forward in DECNN. After repeating this embedding procedure for several times in the network, we can eventually synthesize a final CT image in the end of the DECNN. We have validated our proposed method on both brain and prostate imaging datasets, by also comparing with the state-of-the-art methods. Experimental results suggest that our DECNN (with repeated embedding operations) demonstrates its superior performances, in terms of both the perceptive quality of the synthesized CT image and the run-time cost for synthesizing a CT image. Copyright © 2018. Published by Elsevier B.V.

  7. Prostate Postbrachytherapy Seed Distribution: Comparison of High-Resolution, Contrast-Enhanced, T1- and T2-Weighted Endorectal Magnetic Resonance Imaging Versus Computed Tomography: Initial Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bloch, B. Nicolas; Department of Radiology, General Hospital Vienna, Medical University Vienna, Vienna; Lenkinski, Robert E.

    2007-09-01

    Purpose: To compare contrast-enhanced, T1-weighted, three-dimensional magnetic resonance imaging (CEMR) and T2-weighted magnetic resonance imaging (T2MR) with computed tomography (CT) for prostate brachytherapy seed location for dosimetric calculations. Methods and Materials: Postbrachytherapy prostate MRI was performed on a 1.5 Tesla unit with combined surface and endorectal coils in 13 patients. Both CEMR and T2MR used a section thickness of 3 mm. Spiral CT used a section thickness of 5 mm with a pitch factor of 1.5. All images were obtained in the transverse plane. Two readers using CT and MR imaging assessed brachytherapy seed distribution independently. The dependency of datamore » read by both readers for a specific subject was assessed with a linear mixed effects model. Results: The mean percentage ({+-} standard deviation) values of the readers for seed detection and location are presented. Of 1205 implanted seeds, CEMR, T2MR, and CT detected 91.5% {+-} 4.8%, 78.5% {+-} 8.5%, and 96.1% {+-} 2.3%, respectively, with 11.8% {+-} 4.5%, 8.5% {+-} 3.5%, 1.9% {+-} 1.0% extracapsular, respectively. Assignment to periprostatic structures was not possible with CT. Periprostatic seed assignments for CEMR and T2MR, respectively, were as follows: neurovascular bundle, 3.5% {+-} 1.6% and 2.1% {+-} 0.9%; seminal vesicles, 0.9% {+-} 1.8% and 0.3% {+-} 0.7%; periurethral, 7.1% {+-} 3.3% and 5.8% {+-} 2.9%; penile bulb, 0.6% {+-} 0.8% and 0.3% {+-} 0.6%; Denonvillier's Fascia/rectal wall, 0.5% {+-} 0.6% and 0%; and urinary bladder, 0.1% {+-} 0.3% and 0%. Data dependency analysis showed statistical significance for the type of imaging but not for reader identification. Conclusion: Both enumeration and localization of implanted seeds are readily accomplished with CEMR. Calculations with MRI dosimetry do not require CT data. Dose determinations to specific extracapsular sites can be obtained with MRI but not with CT.« less

  8. Effect of Intensive Statin Therapy on Coronary High-Intensity Plaques Detected by Noncontrast T1-Weighted Imaging: The AQUAMARINE Pilot Study.

    PubMed

    Noguchi, Teruo; Tanaka, Atsushi; Kawasaki, Tomohiro; Goto, Yoichi; Morita, Yoshiaki; Asaumi, Yasuhide; Nakao, Kazuhiro; Fujiwara, Reiko; Nishimura, Kunihiro; Miyamoto, Yoshihiro; Ishihara, Masaharu; Ogawa, Hisao; Koga, Nobuhiko; Narula, Jagat; Yasuda, Satoshi

    2015-07-21

    Coronary high-intensity plaques detected by noncontrast T1-weighted imaging may represent plaque instability. High-intensity plaques can be quantitatively assessed by a plaque-to-myocardium signal-intensity ratio (PMR). This pilot, hypothesis-generating study sought to investigate whether intensive statin therapy would lower PMR. Prospective serial noncontrast T1-weighted magnetic resonance imaging and computed tomography angiography were performed in 48 patients with coronary artery disease at baseline and after 12 months of intensive pitavastatin treatment with a target low-density lipoprotein cholesterol level <80 mg/dl. The control group consisted of coronary artery disease patients not treated with statins that were matched by propensity scoring (n = 48). The primary endpoint was the 12-month change in PMR. Changes in computed tomography angiography parameters and high-sensitivity C-reactive protein levels were analyzed. In the statin group, 12 months of statin therapy significantly improved low-density lipoprotein cholesterol levels (125 to 70 mg/dl; p < 0.001), PMR (1.38 to 1.11, an 18.9% reduction; p < 0.001), low-attenuation plaque volume, and the percentage of total atheroma volume on computed tomography. In the control group, the PMR increased significantly (from 1.22 to 1.49, a 19.2% increase; p < 0.001). Changes in PMR were correlated with changes in low-density lipoprotein cholesterol (r = 0.533; p < 0.001), high-sensitivity C-reactive protein (r = 0.347; p < 0.001), percentage of atheroma volume (r = 0.477; p < 0.001), and percentage of low-attenuation plaque volume (r = 0.416; p < 0.001). Statin treatment significantly reduced the PMR of high-intensity plaques. Noncontrast T1-weighted magnetic resonance imaging could become a useful technique for repeated quantitative assessment of plaque composition. (Attempts at Plaque Vulnerability Quantification with Magnetic Resonance Imaging Using Noncontrast T1-weighted Technique [AQUAMARINE

  9. Comparison among T1-weighted magnetic resonance imaging, modified dixon method, and magnetic resonance spectroscopy in measuring bone marrow fat.

    PubMed

    Shen, Wei; Gong, Xiuqun; Weiss, Jessica; Jin, Ye

    2013-01-01

    An increasing number of studies are utilizing different magnetic resonance (MR) methods to quantify bone marrow fat due to its potential role in osteoporosis. Our aim is to compare the measurements of bone marrow fat among T1-weighted magnetic resonance imaging (MRI), modified Dixon method (also called fat fraction MRI (FFMRI)), and magnetic resonance spectroscopy (MRS). Contiguous MRI scans were acquired in 27 Caucasian postmenopausal women with a modified Dixon method (i.e., FFMRI). Bone marrow adipose tissue (BMAT) of T1-weighted MRI and bone marrow fat fraction of the L3 vertebra and femoral necks were quantified using SliceOmatic and Matlab. MRS was also acquired at the L3 vertebra. Correlation among the three MR methods measured bone marrow fat fraction and BMAT ranges from 0.78 to 0.88 (P < 0.001) in the L3 vertebra. Correlation between BMAT measured by T1-weighted MRI and bone marrow fat fraction measured by modified FFMRI is 0.86 (P < 0.001) in femoral necks. There are good correlations among T1-weighted MRI, FFMRI, and MRS for bone marrow fat quantification. The inhomogeneous distribution of bone marrow fat, the threshold segmentation of the T1-weighted MRI, and the ambiguity of the FFMRI may partially explain the difference among the three methods.

  10. Comparison among T1-Weighted Magnetic Resonance Imaging, Modified Dixon Method, and Magnetic Resonance Spectroscopy in Measuring Bone Marrow Fat

    PubMed Central

    Shen, Wei; Gong, Xiuqun; Weiss, Jessica; Jin, Ye

    2013-01-01

    Introduction. An increasing number of studies are utilizing different magnetic resonance (MR) methods to quantify bone marrow fat due to its potential role in osteoporosis. Our aim is to compare the measurements of bone marrow fat among T1-weighted magnetic resonance imaging (MRI), modified Dixon method (also called fat fraction MRI (FFMRI)), and magnetic resonance spectroscopy (MRS). Methods. Contiguous MRI scans were acquired in 27 Caucasian postmenopausal women with a modified Dixon method (i.e., FFMRI). Bone marrow adipose tissue (BMAT) of T1-weighted MRI and bone marrow fat fraction of the L3 vertebra and femoral necks were quantified using SliceOmatic and Matlab. MRS was also acquired at the L3 vertebra. Results. Correlation among the three MR methods measured bone marrow fat fraction and BMAT ranges from 0.78 to 0.88 (P < 0.001) in the L3 vertebra. Correlation between BMAT measured by T1-weighted MRI and bone marrow fat fraction measured by modified FFMRI is 0.86 (P < 0.001) in femoral necks. Conclusion. There are good correlations among T1-weighted MRI, FFMRI, and MRS for bone marrow fat quantification. The inhomogeneous distribution of bone marrow fat, the threshold segmentation of the T1-weighted MRI, and the ambiguity of the FFMRI may partially explain the difference among the three methods. PMID:23606951

  11. Hyperintense Dentate Nuclei on T1-Weighted MRI: Relation to Repeat Gadolinium Administration

    PubMed Central

    Adin, M.E.; Kleinberg, L.; Vaidya, D.; Zan, E.; Mirbagheri, S.; Yousem, D.M.

    2016-01-01

    BACKGROUND AND PURPOSE A hyperintense appearance of the dentate nucleus on T1-weighted MR images has been related to various clinical conditions, but the etiology remains indeterminate. We aimed to investigate the possible associations between a hyperintense appearance of the dentate nucleus on T1-weighted MR images in patients exposed to radiation and factors including, but not limited to, the cumulative number of contrast-enhanced MR images, amount of gadolinium administration, dosage of ionizing radiation, and patient demographics. MATERIALS AND METHODS The medical records of 706 consecutive patients who were treated with brain irradiation at The Johns Hopkins Medical Institutions between 1995 and 2010 were blindly reviewed by 2 readers. RESULTS One hundred eighty-four subjects were included for dentate nuclei analysis. Among the 184 subjects who cumulatively underwent 2677 MR imaging studies following intravenous gadolinium administration, 103 patients had hyperintense dentate nuclei on precontrast T1-weighted MR images. The average number of gadolinium-enhanced MR imaging studies performed in the group with normal dentate nuclei was significantly lower than that of the group with hyperintense dentate nuclei. The average follow-up time was 62.5 months. No significant difference was observed between hyperintense and normal dentate nuclei groups in terms of exposed radiation dose, serum creatinine and calcium/phosphate levels, patient demographics, history of chemotherapy, and strength of the scanner. No dentate nuclei abnormalities were found on the corresponding CT scans of patients with hyperintense dentate nuclei (n = 44). No dentate nuclei abnormalities were found in 53 healthy volunteers. CONCLUSIONS Repeat performance of gadolinium-enhanced studies likely contributes to a long-standing hyperintense appearance of dentate nuclei on precontrast T1-weighted-MR images. PMID:26294649

  12. Comparison of amyloid plaque contrast generated by T2-, T2*-, and susceptibility-weighted imaging methods in transgenic mouse models of Alzheimer’s disease

    PubMed Central

    Chamberlain, Ryan; Reyes, Denise; Curran, Geoffrey L.; Marjanska, Malgorzata; Wengenack, Thomas M.; Poduslo, Joseph F.; Garwood, Michael; Jack, Clifford R.

    2009-01-01

    One of the hallmark pathologies of Alzheimer’s disease (AD) is amyloid plaque deposition. Plaques appear hypointense on T2- and T2*-weighted MR images probably due to the presence of endogenous iron, but no quantitative comparison of various imaging techniques has been reported. We estimated the T1, T2, T2*, and proton density values of cortical plaques and normal cortical tissue and analyzed the plaque contrast generated by a collection of T2-, T2*-, and susceptibility-weighted imaging (SWI) methods in ex vivo transgenic mouse specimens. The proton density and T1 values were similar for both cortical plaques and normal cortical tissue. The T2 and T2* values were similar in cortical plaques, which indicates that the iron content of cortical plaques may not be as large as previously thought. Ex vivo plaque contrast was increased compared to a previously reported spin echo sequence by summing multiple echoes and by performing SWI; however, gradient echo and susceptibility weighted imaging was found to be impractical for in vivo imaging due to susceptibility interface-related signal loss in the cortex. PMID:19253386

  13. Independent value of image fusion in unenhanced breast MRI using diffusion-weighted and morphological T2-weighted images for lesion characterization in patients with recently detected BI-RADS 4/5 x-ray mammography findings.

    PubMed

    Bickelhaupt, Sebastian; Tesdorff, Jana; Laun, Frederik Bernd; Kuder, Tristan Anselm; Lederer, Wolfgang; Teiner, Susanne; Maier-Hein, Klaus; Daniel, Heidi; Stieber, Anne; Delorme, Stefan; Schlemmer, Heinz-Peter

    2017-02-01

    The aim of this study was to evaluate the accuracy and applicability of solitarily reading fused image series of T2-weighted and high-b-value diffusion-weighted sequences for lesion characterization as compared to sequential or combined image analysis of these unenhanced sequences and to contrast- enhanced breast MRI. This IRB-approved study included 50 female participants with suspicious breast lesions detected in screening X-ray mammograms, all of which provided written informed consent. Prior to biopsy, all women underwent MRI including diffusion-weighted imaging (DWIBS, b = 1500s/mm 2 ). Images were analyzed as follows: prospective image fusion of DWIBS and T2-weighted images (FU), side-by-side analysis of DWIBS and T2-weighted series (CO), combination of the first two methods (CO+FU), and full contrast-enhanced diagnostic protocol (FDP). Diagnostic indices, confidence, and image quality of the protocols were compared by two blinded readers. Reading the CO+FU (accuracy 0.92; NPV 96.1 %; PPV 87.6 %) and the CO series (0.90; 96.1 %; 83.7 %) provided a diagnostic performance similar to the FDP (0.95; 96.1 %; 91.3 %; p > 0.05). FU reading alone significantly reduced the diagnostic accuracy (0.82; 93.3 %; 73.4 %; p = 0.023). MR evaluation of suspicious BI-RADS 4 and 5 lesions detected on mammography by using a non-contrast-enhanced T2-weighted and DWIBS sequence protocol is most accurate if MR images were read using the CO+FU protocol. • Unenhanced breast MRI with additional DWIBS/T2w-image fusion allows reliable lesion characterization. • Abbreviated reading of fused DWIBS/T2w-images alone decreases diagnostic confidence and accuracy. • Reading fused DWIBS/T2w-images as the sole diagnostic method should be avoided.

  14. Diffusion-weighted magnetic resonance imaging combined with T2-weighted images in the detection of small breast cancer: a single-center multi-observer study.

    PubMed

    Wu, Lian-Ming; Chen, Jie; Hu, Jiani; Gu, Hai-Yan; Xu, Jian-Rong; Hua, Jia

    2014-02-01

    Breast cancer is the most common cancer in women worldwide. However, it remains a difficult diagnosis problem to differentiate between benign and malignant breast lesions, especially in small early breast lesions. To assess the diagnostic value of diffusion-weighted imaging (DWI) combined with T2-weighted imaging (T2WI) for small breast cancer characterization. Fifty-eight patients (65 lesions) with a lesion <2 cm in diameter underwent 3.0 Tesla breast magnetic resonance imaging (MRI) including DWI and histological analysis. Three observers with varying experience levels reviewed MRI. The probability of breast cancer in each lesion on MR images was recorded with a 5-point scale. Areas under the receiver-operating characteristic curve (AUCs) were compared by using the Z test; sensitivity and specificity were determined with the Z test after adjusting for data clustering. AUC of T2WI and DWI (Observer 1, 0.95; Observer 2, 0.91; Observer 3, 0.83) was greater than that of T2WI (Observer 1, 0.80; Observer 2, 0.74; Observer 3, 0.70) for all observers (P < 0.0001 in all comparisons). Sensitivity of T2WI and DWI (Observer 1, 90%; Observer 2, 93%; and Observer 3, 86%) was greater than that of T2WI alone (Observer 1, 76%; Observer 2, 83%; Observer 3, 79%) for all observers (P < 0.0001 in all comparisons). Specificity of T2WI and DWI was greater than that of T2WI alone for observer 1 (89% vs. 72%, P < 0.01) and observer 2 (94% vs. 78%, P < 0.001). DWI combined with T2WI can improve the diagnostic performance of MRI in small breast cancer characterization. It should be considered selectively in the preoperative evaluation of patients with small lesions of the breast.

  15. T1ρ MR Imaging of Human Musculoskeletal System

    PubMed Central

    Wang, Ligong; Regatte, Ravinder R.

    2014-01-01

    Magnetic resonance imaging (MRI) offers the direct visualization of human musculoskeletal (MSK) system, especially all diarthrodial tissues including cartilage, bone, menisci, ligaments, tendon, hip, synovium etc. Conventional MR imaging techniques based on T1- and T2-weighted, proton density (PD) contrast are inconclusive in quantifying early biochemically degenerative changes in MSK system in general and articular cartilage in particular. In recent years, quantitative MR parameter mapping techniques have been used to quantify the biochemical changes in articular cartilage with a special emphasis on evaluating joint injury, cartilage degeneration, and soft tissue repair. In this article, we will focus on cartilage biochemical composition, basic principles of T1ρ MR imaging, implementation of T1ρ pulse sequences, biochemical validation, and summarize the potential applications of T1ρ MR imaging technique in MSK diseases including osteoarthritis (OA), anterior cruciate ligament (ACL) injury, and knee joint repair. Finally, we will also review the potential advantages, challenges, and future prospects of T1ρ MR imaging for widespread clinical translation. PMID:24935818

  16. Technique of diffusion weighted imaging and its application in stroke

    NASA Astrophysics Data System (ADS)

    Li, Enzhong; Tian, Jie; Han, Ying; Wang, Huifang; Li, Wu; He, Huiguang

    2003-05-01

    To study the application of diffusion weighted imaging and image post processing in the diagnosis of stroke, especially in acute stroke, 205 patients were examined by 1.5 T or 1.0 T MRI scanner and the images such as T1, T2 and diffusion weighted images were obtained. Image post processing was done with "3D Med System" developed by our lab to analyze data and acquire the apparent diffusion coefficient (ADC) map. In acute and subacute stage of stroke, the signal in cerebral infarction areas changed to hyperintensity in T2- and diffusion-weighted images, normal or hypointensity in T1-weighted images. In hyperacute stage, however, the signal was hyperintense just in the diffusion weighted imaes; others were normal. In the chronic stage, the signal in T1- and diffusion-weighted imaging showed hypointensity and hyperintensity in T2 weighted imaging. Because ADC declined obviously in acute and subacute stage of stroke, the lesion area was hypointensity in ADC map. With the development of the disease, ADC gradually recovered and then changed to hyperintensity in ADC map in chronic stage. Using diffusion weighted imaging and ADC mapping can make a diagnosis of stroke, especially in the hyperacute stage of stroke, and can differentiate acute and chronic stroke.

  17. Evaluation of neonatal brain myelination using the T1- and T2-weighted MRI ratio.

    PubMed

    Soun, Jennifer E; Liu, Michael Z; Cauley, Keith A; Grinband, Jack

    2017-09-01

    To validate the T1- and T2-weighted (T1w/T2w) MRI ratio technique in evaluating myelin in the neonatal brain. T1w and T2w MR images of 10 term neonates with normal-appearing brain parenchyma were obtained from a single 1.5 Tesla MRI and retrospectively analyzed. T1w/T2w ratio images were created with a postprocessing pipeline and qualitatively compared with standard clinical sequences (T1w, T2w, and apparent diffusion coefficient [ADC]). Quantitative assessment was also performed to assess the ratio technique in detecting areas of known myelination (e.g., posterior limb of the internal capsule) and very low myelination (e.g., optic radiations) using linear regression analysis and the Michelson Contrast equation, a measure of luminance contrast intensity. The ratio image provided qualitative improvements in the ability to visualize regional variation in myelin content of neonates. Linear regression analysis demonstrated a significant inverse relationship between the ratio intensity values and ADC values in the posterior limb of the internal capsule and the optic radiations (R 2  = 0.96 and P < 0.001). The Michelson Contrast equation showed that contrast differences between these two regions for the ratio images were 1.6 times higher than T1w, 2.6 times higher than T2w, and 1.8 times higher than ADC (all P < 0.001). Finally, the ratio improved visualization of the corticospinal tract, one of the earliest myelinated pathways. The T1w/T2w ratio accentuates contrast between myelinated and less myelinated structures and may enhance our diagnostic ability to detect myelination patterns in the neonatal brain. 2 Technical Efficacy: Stage2 J. MAGN. RESON. IMAGING 2017;46:690-696. © 2016 International Society for Magnetic Resonance in Medicine.

  18. A study of T2-weighted MR image texture features and diffusion-weighted MR image features for computer-aided diagnosis of prostate cancer

    NASA Astrophysics Data System (ADS)

    Peng, Yahui; Jiang, Yulei; Antic, Tatjana; Giger, Maryellen L.; Eggener, Scott; Oto, Aytekin

    2013-02-01

    The purpose of this study was to study T2-weighted magnetic resonance (MR) image texture features and diffusionweighted (DW) MR image features in distinguishing prostate cancer (PCa) from normal tissue. We collected two image datasets: 23 PCa patients (25 PCa and 23 normal tissue regions of interest [ROIs]) imaged with Philips MR scanners, and 30 PCa patients (41 PCa and 26 normal tissue ROIs) imaged with GE MR scanners. A radiologist drew ROIs manually via consensus histology-MR correlation conference with a pathologist. A number of T2-weighted texture features and apparent diffusion coefficient (ADC) features were investigated, and linear discriminant analysis (LDA) was used to combine select strong image features. Area under the receiver operating characteristic (ROC) curve (AUC) was used to characterize feature effectiveness in distinguishing PCa from normal tissue ROIs. Of the features studied, ADC 10th percentile, ADC average, and T2-weighted sum average yielded AUC values (+/-standard error) of 0.95+/-0.03, 0.94+/-0.03, and 0.85+/-0.05 on the Phillips images, and 0.91+/-0.04, 0.89+/-0.04, and 0.70+/-0.06 on the GE images, respectively. The three-feature combination yielded AUC values of 0.94+/-0.03 and 0.89+/-0.04 on the Phillips and GE images, respectively. ADC 10th percentile, ADC average, and T2-weighted sum average, are effective in distinguishing PCa from normal tissue, and appear robust in images acquired from Phillips and GE MR scanners.

  19. 3D T2-weighted and Gd-EOB-DTPA-enhanced 3D T1-weighted MR cholangiography for evaluation of biliary anatomy in living liver donors.

    PubMed

    Cai, Larry; Yeh, Benjamin M; Westphalen, Antonio C; Roberts, John; Wang, Zhen J

    2017-03-01

    To investigate whether the addition of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced 3D T1-weighted MR cholangiography (T1w-MRC) to 3D T2-weighted MRC (T2w-MRC) improves the confidence and diagnostic accuracy of biliary anatomy in living liver donors. Two abdominal radiologists retrospectively and independently reviewed pre-operative MR studies in 58 consecutive living liver donors. The second-order bile duct visualization on T1w- and T2w-MRC images was rated on a 4-point scale. The readers also independently recorded the biliary anatomy and their diagnostic confidence using (1) combined T1w- and T2w-MRC, and (2) T2w-MRC. In the 23 right lobe donors, the biliary anatomy at imaging and the imaging-predicted number of duct orifices at surgery were compared to intra-operative findings. T1w-MRC had a higher proportion of excellent visualization than T2w-MRC, 66% vs. 45% for reader 1 and 60% vs. 31% for reader 2. The median confidence score for biliary anatomy diagnosis was significantly higher with combined T1w- and T2w-MRC than T2w-MRC alone for both readers (Reader 1: 3 vs. 2, p < 0.001; Reader 2: 3 vs. 1, p < 0.001). Compared to intra-operative findings, the accuracy of imaging-predicted number of duct orifices using combined T1w-and T2w-MRC was significantly higher than that using T2w-MRC alone (p = 0.034 for reader 1, p = 0.0082 for reader 2). The addition of Gd-EOB-DTPA-enhanced 3D T1w-MRC to 3D T2w-MRC improves second-order bile duct visualization and increases the confidence in biliary anatomy diagnosis and the accuracy in the imaging-predicted number of duct orifices acquired during right lobe harvesting.

  20. Registration of T2-weighted and diffusion-weighted MR images of the prostate: comparison between manual and landmark-based methods

    NASA Astrophysics Data System (ADS)

    Peng, Yahui; Jiang, Yulei; Soylu, Fatma N.; Tomek, Mark; Sensakovic, William; Oto, Aytekin

    2012-02-01

    Quantitative analysis of multi-parametric magnetic resonance (MR) images of the prostate, including T2-weighted (T2w) and diffusion-weighted (DW) images, requires accurate image registration. We compared two registration methods between T2w and DW images. We collected pre-operative MR images of 124 prostate cancer patients (68 patients scanned with a GE scanner and 56 with Philips scanners). A landmark-based rigid registration was done based on six prostate landmarks in both T2w and DW images identified by a radiologist. Independently, a researcher manually registered the same images. A radiologist visually evaluated the registration results by using a 5-point ordinal scale of 1 (worst) to 5 (best). The Wilcoxon signed-rank test was used to determine whether the radiologist's ratings of the results of the two registration methods were significantly different. Results demonstrated that both methods were accurate: the average ratings were 4.2, 3.3, and 3.8 for GE, Philips, and all images, respectively, for the landmark-based method; and 4.6, 3.7, and 4.2, respectively, for the manual method. The manual registration results were more accurate than the landmark-based registration results (p < 0.0001 for GE, Philips, and all images). Therefore, the manual method produces more accurate registration between T2w and DW images than the landmark-based method.

  1. Optimization of T2-weighted imaging for shoulder magnetic resonance arthrography by synthetic magnetic resonance imaging.

    PubMed

    Lee, Seung Hyun; Lee, Young Han; Hahn, Seok; Yang, Jaemoon; Song, Ho-Taek; Suh, Jin-Suck

    2017-01-01

    Background Synthetic magnetic resonance imaging (MRI) allows reformatting of various synthetic images by adjustment of scanning parameters such as repetition time (TR) and echo time (TE). Optimized MR images can be reformatted from T1, T2, and proton density (PD) values to achieve maximum tissue contrast between joint fluid and adjacent soft tissue. Purpose To demonstrate the method for optimization of TR and TE by synthetic MRI and to validate the optimized images by comparison with conventional shoulder MR arthrography (MRA) images. Material and Methods Thirty-seven shoulder MRA images acquired by synthetic MRI were retrospectively evaluated for PD, T1, and T2 values at the joint fluid and glenoid labrum. Differences in signal intensity between the fluid and labrum were observed between TR of 500-6000 ms and TE of 80-300 ms in T2-weighted (T2W) images. Conventional T2W and synthetic images were analyzed for diagnostic agreement of supraspinatus tendon abnormalities (kappa statistics) and image quality scores (one-way analysis of variance with post-hoc analysis). Results Optimized mean values of TR and TE were 2724.7 ± 1634.7 and 80.1 ± 0.4, respectively. Diagnostic agreement for supraspinatus tendon abnormalities between conventional and synthetic MR images was excellent (κ = 0.882). The mean image quality score of the joint space in optimized synthetic images was significantly higher compared with those in conventional and synthetic images (2.861 ± 0.351 vs. 2.556 ± 0.607 vs. 2.750 ± 0.439; P < 0.05). Conclusion Synthetic MRI with optimized TR and TE for shoulder MRA enables optimization of soft-tissue contrast.

  2. Prostate segmentation in MRI using fused T2-weighted and elastography images

    NASA Astrophysics Data System (ADS)

    Nir, Guy; Sahebjavaher, Ramin S.; Baghani, Ali; Sinkus, Ralph; Salcudean, Septimiu E.

    2014-03-01

    Segmentation of the prostate in medical imaging is a challenging and important task for surgical planning and delivery of prostate cancer treatment. Automatic prostate segmentation can improve speed, reproducibility and consistency of the process. In this work, we propose a method for automatic segmentation of the prostate in magnetic resonance elastography (MRE) images. The method utilizes the complementary property of the elastogram and the corresponding T2-weighted image, which are obtained from the phase and magnitude components of the imaging signal, respectively. It follows a variational approach to propagate an active contour model based on the combination of region statistics in the elastogram and the edge map of the T2-weighted image. The method is fast and does not require prior shape information. The proposed algorithm is tested on 35 clinical image pairs from five MRE data sets, and is evaluated in comparison with manual contouring. The mean absolute distance between the automatic and manual contours is 1.8mm, with a maximum distance of 5.6mm. The relative area error is 7.6%, and the duration of the segmentation process is 2s per slice.

  3. Breast MRI at 7 Tesla with a bilateral coil and T1-weighted acquisition with robust fat suppression: image evaluation and comparison with 3 Tesla

    PubMed Central

    Brown, Ryan; Storey, Pippa; Geppert, Christian; McGorty, KellyAnne; Leite, Ana Paula Klautau; Babb, James; Sodickson, Daniel K.; Wiggins, Graham C.; Moy, Linda

    2014-01-01

    Objectives To evaluate the image quality of T1-weighted fat-suppressed breast MRI at 7 T, and to compare 7-T and 3-T images. Methods Seventeen subjects were imaged using a 7-T bilateral transmit-receive coil and adiabatic inversion-based fat suppression (FS). Images were graded on a five-point scale and quantitatively assessed through signal-to-noise ratio (SNR), fibroglandular/fat contrast and signal uniformity measurements. Results Image scores at 7 T and 3 T were similar on standard-resolution images (1.1× 1.1×1.11.6 mm3), indicating that high-quality breast imaging with clinical parameters can be performed at 7 T. The 7-T SNR advantage was underscored on 0.6-mm isotropic images, where image quality was significantly greater than at 3 T (4.2 versus 3.1, P≤0.0001). Fibroglandular/fat contrast was more than two times higher at 7 T over 3 T, owing to effective adiabatic inversion-based FS and the inherent 7 T signal advantage. Signal uniformity was comparable at 7 T and 3 T (P<0.05). Similar 7-T image quality was observed in all subjects, indicating robustness against anatomical variation. Conclusion The 7-T bilateral transmit-receive coil and adiabatic inversion-based FS technique mitigate the impact of high-field heterogeneity to produce image quality that is as good as or better than at 3 T PMID:23896763

  4. [Parametrial infiltration of cervix carcinoma: diagnostic value of contrast-enhanced fat-suppressed T1-weighted SE sequences at 1.5 tesla].

    PubMed

    Scheidler, J; Heuck, A; Wencke, K; Kimmig, R; Müller-Lisse, U; Reiser, M

    1997-04-01

    To determine whether contrast-enhanced and fat-suppressed sequences contribute to the MR imaging diagnosis of parametrial invasion. 21 patients with carcinoma of the cervix were prospectively examined with a phased-array coil and a 1.5T MR-scanner using the following sequences: transverse T2-weighted turbo spin echo (T2-TSE), T1-weighted spin echo (T1-SE) and fat suppressed T1-weighted SE sequences before and after Gd-DTPA. The sequences were evaluated separately for the presence of parametrial invasion. Image quality and diagnostic confidence were classified on a scale of 0-10 (nondiagnostic-excellent). Findings were compared to the results of the pathohistological examination. Sensitivity, specificity and diagnostic accuracy were highest for T2-TSE sequences (100%, 79% and 86%, respectively). Contrast-enhanced T1-SE sequences with fat-suppression (71%, 79%, and 76%) showed no improvement compared to T2-TSE. Unenhanced fat-suppressed T1-SE (100%, 30%, and 56%) and unenhanced T1-SE (100%, 7%, and 38%) as well as contrast-enhanced T1-SE (86%, 20%, and 47%) were significantly worse than T2-TSE. With similar image quality (p < 0.05) diagnostic confidence was higher on T2-TSE than on any of the other sequences (p < 0.001). Considering the cost-effectiveness of the examination, for the MR diagnosis of parametrial invasion the use of fat-suppressed contrast-enhanced sequences can be abandoned in favour of T2-weighted TSE sequences.

  5. A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo.

    PubMed

    Li, Z; Hu, H H; Miller, J H; Karis, J P; Cornejo, P; Wang, D; Pipe, J G

    2016-04-01

    A challenge with the T1-weighted postcontrast Cartesian spin-echo and turbo spin-echo brain MR imaging is the presence of flow artifacts. Our aim was to develop a rapid 2D spiral spin-echo sequence for T1-weighted MR imaging with minimal flow artifacts and to compare it with a conventional Cartesian 2D turbo spin-echo sequence. T1-weighted brain imaging was performed in 24 pediatric patients. After the administration of intravenous gadolinium contrast agent, a reference Cartesian TSE sequence with a scanning time of 2 minutes 30 seconds was performed, followed by the proposed spiral spin-echo sequence with a scanning time of 1 minutes 18 seconds, with similar spatial resolution and volumetric coverage. The results were reviewed independently and blindly by 3 neuroradiologists. Scores from a 3-point scale were assigned in 3 categories: flow artifact reduction, subjective preference, and lesion conspicuity, if any. The Wilcoxon signed rank test was performed to evaluate the reviewer scores. The t test was used to evaluate the SNR. The Fleiss κ coefficient was calculated to examine interreader agreement. In 23 cases, spiral spin-echo was scored over Cartesian TSE in flow artifact reduction (P < .001). In 21 cases, spiral spin-echo was rated superior in subjective preference (P < .001). Ten patients were identified with lesions, and no statistically significant difference in lesion conspicuity was observed between the 2 sequences. There was no statistically significant difference in SNR between the 2 techniques. The Fleiss κ coefficient was 0.79 (95% confidence interval, 0.65-0.93). The proposed spiral spin-echo pulse sequence provides postcontrast images with minimal flow artifacts at a faster scanning time than its Cartesian TSE counterpart. © 2016 by American Journal of Neuroradiology.

  6. High-resolution T2-weighted cervical cancer imaging: a feasibility study on ultra-high-field 7.0-T MRI with an endorectal monopole antenna.

    PubMed

    Hoogendam, Jacob P; Kalleveen, Irene M L; de Castro, Catalina S Arteaga; Raaijmakers, Alexander J E; Verheijen, René H M; van den Bosch, Maurice A A J; Klomp, Dennis W J; Zweemer, Ronald P; Veldhuis, Wouter B

    2017-03-01

    We studied the feasibility of high-resolution T 2 -weighted cervical cancer imaging on an ultra-high-field 7.0-T magnetic resonance imaging (MRI) system using an endorectal antenna of 4.7-mm thickness. A feasibility study on 20 stage IB1-IIB cervical cancer patients was conducted. All underwent pre-treatment 1.5-T MRI. At 7.0-T MRI, an external transmit/receive array with seven dipole antennae and a single endorectal monopole receive antenna were used. Discomfort levels were assessed. Following individualised phase-based B 1 + shimming, T 2 -weighted turbo spin echo sequences were completed. Patients had stage IB1 (n = 9), IB2 (n = 4), IIA1 (n = 1) or IIB (n = 6) cervical cancer. Discomfort (ten-point scale) was minimal at placement and removal of the endorectal antenna with a median score of 1 (range, 0-5) and 0 (range, 0-2) respectively. Its use did not result in adverse events or pre-term session discontinuation. To demonstrate feasibility, T 2 -weighted acquisitions from 7.0-T MRI are presented in comparison to 1.5-T MRI. Artefacts on 7.0-T MRI were due to motion, locally destructive B 1 interference, excessive B 1 under the external antennae and SENSE reconstruction. High-resolution T 2 -weighted 7.0-T MRI of stage IB1-IIB cervical cancer is feasible. The addition of an endorectal antenna is well tolerated by patients. • High resolution T 2 -weighted 7.0-T MRI of the inner female pelvis is challenging • We demonstrate a feasible approach for T 2 -weighted 7.0-T MRI of cervical cancer • An endorectal monopole receive antenna is well tolerated by participants • The endorectal antenna did not lead to adverse events or session discontinuation.

  7. Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient?

    PubMed

    Alibek, Sedat; Adamietz, Boris; Cavallaro, Alexander; Stemmer, Alto; Anders, Katharina; Kramer, Manuel; Bautz, Werner; Staatz, Gundula

    2008-08-01

    We compared contrast-enhanced T1-weighted magnetic resonance (MR) imaging of the brain using different types of data acquisition techniques: periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER, BLADE) imaging versus standard k-space sampling (conventional spin-echo pulse sequence) in the unsedated pediatric patient with focus on artifact reduction, overall image quality, and lesion detectability. Forty-eight pediatric patients (aged 3 months to 18 years) were scanned with a clinical 1.5-T whole body MR scanner. Cross-sectional contrast-enhanced T1-weighted spin-echo sequence was compared to a T1-weighted dark-fluid fluid-attenuated inversion-recovery (FLAIR) BLADE sequence for qualitative and quantitative criteria (image artifacts, image quality, lesion detectability) by two experienced radiologists. Imaging protocols were matched for imaging parameters. Reader agreement was assessed using the exact Bowker test. BLADE images showed significantly less pulsation and motion artifacts than the standard T1-weighted spin-echo sequence scan. BLADE images showed statistically significant lower signal-to-noise ratio but higher contrast-to-noise ratios with superior gray-white matter contrast. All lesions were demonstrated on FLAIR BLADE imaging, and one false-positive lesion was visible in spin-echo sequence images. BLADE MR imaging at 1.5 T is applicable for central nervous system imaging of the unsedated pediatric patient, reduces motion and pulsation artifacts, and minimizes the need for sedation or general anesthesia without loss of relevant diagnostic information.

  8. Molecular Imaging of Tumors Using a Quantitative T1 Mapping Technique via Magnetic Resonance Imaging

    PubMed Central

    Herrmann, Kelsey; Johansen, Mette L.; Craig, Sonya E.; Vincent, Jason; Howell, Michael; Gao, Ying; Lu, Lan; Erokwu, Bernadette; Agnes, Richard S.; Lu, Zheng-Rong; Pokorski, Jonathan K.; Basilion, James; Gulani, Vikas; Griswold, Mark; Flask, Chris; Brady-Kalnay, Susann M.

    2015-01-01

    Magnetic resonance imaging (MRI) of glioblastoma multiforme (GBM) with molecular imaging agents would allow for the specific localization of brain tumors. Prior studies using T1-weighted MR imaging demonstrated that the SBK2-Tris-(Gd-DOTA)3 molecular imaging agent labeled heterotopic xenograft models of brain tumors more intensely than non-specific contrast agents using conventional T1-weighted imaging techniques. In this study, we used a dynamic quantitative T1 mapping strategy to more objectively compare intra-tumoral retention of the SBK2-Tris-(Gd-DOTA)3 agent over time in comparison to non-targeted control agents. Our results demonstrate that the targeted SBK2-Tris-(Gd-DOTA)3 agent, a scrambled-Tris-(Gd-DOTA)3 control agent, and the non-specific clinical contrast agent Optimark™ all enhanced flank tumors of human glioma cells with similar maximal changes on T1 mapping. However, the retention of the agents differs. The non-specific agents show significant recovery within 20 min by an increase in T1 while the specific agent SBK2-Tris-(Gd-DOTA)3 is retained in the tumors and shows little recovery over 60 min. The retention effect is demonstrated by percent change in T1 values and slope calculations as well as by calculations of gadolinium concentration in tumor compared to muscle. Quantitative T1 mapping demonstrates the superior binding and retention in tumors of the SBK2-Tris-(Gd-DOTA)3 agent over time compared to the non-specific contrast agent currently in clinical use. PMID:26435847

  9. T1-Weighted MR imaging of liver tumor by gadolinium-encapsulated glycol chitosan nanoparticles without non-specific toxicity in normal tissues

    NASA Astrophysics Data System (ADS)

    Na, Jin Hee; Lee, Sangmin; Koo, Heebeom; Han, Hyounkoo; Lee, Kyung Eun; Han, Seung Jin; Choi, Seung Hong; Kim, Hyuncheol; Lee, Seulki; Kwon, Ick Chan; Choi, Kuiwon; Kim, Kwangmeyung

    2016-05-01

    Herein, we have synthesized Gd(iii)-encapsulated glycol chitosan nanoparticles (Gd(iii)-CNPs) for tumor-targeted T1-weighted magnetic resonance (MR) imaging. The T1 contrast agent, Gd(iii), was successfully encapsulated into 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-modified CNPs to form stable Gd(iii)-encapsulated CNPs (Gd(iii)-CNPs) with an average particle size of approximately 280 nm. The stable nanoparticle structure of Gd(iii)-CNPs is beneficial for liver tumor accumulation by the enhanced permeation and retention (EPR) effect. Moreover, the amine groups on the surface of Gd(iii)-CNPs could be protonated and could induce fast cellular uptake at acidic pH in tumor tissue. To assay the tumor-targeting ability of Cy5.5-labeled Gd(iii)-CNPs, near-infrared fluorescence (NIRF) imaging and MR imaging were used in a liver tumor model as well as a subcutaneous tumor model. Cy5.5-labeled Gd(iii)-CNPs generated highly intense fluorescence and T1 MR signals in tumor tissues after intravenous injection, while DOTAREM®, the commercialized control MR contrast agent, showed very low tumor-targeting efficiency on MR images. Furthermore, damaged tissues were found in the livers and kidneys of mice injected with DOTAREM®, but there were no obvious adverse effects with Gd(iii)-CNPs. Taken together, these results demonstrate the superiority of Gd(iii)-CNPs as a tumor-targeting T1 MR agent.Herein, we have synthesized Gd(iii)-encapsulated glycol chitosan nanoparticles (Gd(iii)-CNPs) for tumor-targeted T1-weighted magnetic resonance (MR) imaging. The T1 contrast agent, Gd(iii), was successfully encapsulated into 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-modified CNPs to form stable Gd(iii)-encapsulated CNPs (Gd(iii)-CNPs) with an average particle size of approximately 280 nm. The stable nanoparticle structure of Gd(iii)-CNPs is beneficial for liver tumor accumulation by the enhanced permeation and retention (EPR) effect. Moreover, the

  10. T1ρ magnetic resonance: basic physics principles and applications in knee and intervertebral disc imaging.

    PubMed

    Wáng, Yì-Xiáng J; Zhang, Qinwei; Li, Xiaojuan; Chen, Weitian; Ahuja, Anil; Yuan, Jing

    2015-12-01

    T1ρ relaxation time provides a new contrast mechanism that differs from T1- and T2-weighted contrast, and is useful to study low-frequency motional processes and chemical exchange in biological tissues. T1ρ imaging can be performed in the forms of T1ρ-weighted image, T1ρ mapping and T1ρ dispersion. T1ρ imaging, particularly at low spin-lock frequency, is sensitive to B0 and B1 inhomogeneity. Various composite spin-lock pulses have been proposed to alleviate the influence of field inhomogeneity so as to reduce the banding-like spin-lock artifacts. T1ρ imaging could be specific absorption rate (SAR) intensive and time consuming. Efforts to address these issues and speed-up data acquisition are being explored to facilitate wider clinical applications. This paper reviews the T1ρ imaging's basic physic principles, as well as its application for cartilage imaging and intervertebral disc imaging. Compared to more established T2 relaxation time, it has been shown that T1ρ provides more sensitive detection of proteoglycan (PG) loss at early stages of cartilage degeneration. T1ρ has also been shown to provide more sensitive evaluation of annulus fibrosis (AF) degeneration of the discs.

  11. The interplay of T1- and T2-relaxation on T1-weighted MRI of hMSCs induced by Gd-DOTA-peptides.

    PubMed

    Cao, Limin; Li, Binbin; Yi, Peiwei; Zhang, Hailu; Dai, Jianwu; Tan, Bo; Deng, Zongwu

    2014-04-01

    Three Gd-DOTA-peptide complexes with different peptide sequence are synthesized and used as T1 contrast agent to label human mesenchymal stem cells (hMSCs) for magnetic resonance imaging study. The peptides include a universal cell penetrating peptide TAT, a linear MSC-specific peptide EM7, and a cyclic MSC-specific peptide CC9. A significant difference in labeling efficacy is observed between the Gd-DOTA-peptides as well as a control Dotarem. All Gd-DOTA-peptides as well as Dotarem induce significant increase in T1 relaxation rate which is in favor of T1-weighted MR imaging. Gd-DOTA-CC9 yields the maximum labeling efficacy but poor T1 contrast enhancement. Gd-DOTA-EM7 yields the minimum labeling efficacy but better T1 contrast enhancement. Gd-DOTA-TAT yields a similar labeling efficacy as Gd-DOTA-CC9 and similar T1 contrast enhancement as Gd-DOTA-EM7. The underlying mechanism that governs T1 contrast enhancement effect is discussed. Our results suggest that T1 contrast enhancement induced by Gd-DOTA-peptides depends not only on the introduced cellular Gd content, but more importantly on the effect that Gd-DOTA-peptides exert on the T1-relaxation and T2-relaxation processes/rates. Both T1 and particularly T2 relaxation rate have to be taken into account to interpret T1 contrast enhancement. In addition, the interpretation has to be based on cellular instead of aqueous longitudinal and transverse relaxivities of Gd-DOTA-peptides. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Differentiation between cavernous hemangiomas and untreated malignant neoplasms of the liver with free-breathing diffusion-weighted MR imaging: comparison with T2-weighted fast spin-echo MR imaging.

    PubMed

    Soyer, Philippe; Corno, Lucie; Boudiaf, Mourad; Aout, Mounir; Sirol, Marc; Placé, Vinciane; Duchat, Florent; Guerrache, Youcef; Fargeaudou, Yann; Vicaut, Eric; Pocard, Marc; Hamzi, Lounis

    2011-11-01

    To test interobserver variability of ADC measurements and compare the diagnostic performances of free-breathing diffusion-weighted (FBDW) with that of T2-weighted FSE (T2WFSE) MR imaging for differentiating between cavernous hemangiomas and untreated malignant hepatic neoplasms. Thirty-five patients with cavernous hemangiomas and 35 with untreated hepatic malignant neoplasms had FBDW and T2WFSE MR imaging. Hepatic lesions were characterized with ADC measurement and visual evaluation. Interobserver agreement for ADC measurement was calculated. Association between ADC value and lesion type was assessed using univariate analysis. Sensitivity, specificity and accuracy of ADC values and visual evaluation of MR images for the diagnosis of untreated malignant hepatic neoplasm were compared. ADC measurements showed excellent interobserver correlation (intraclass correlation coefficient=0.980). Malignant neoplasms had lower ADC values than hemangiomas for the two observers (1.11×10(-3) mm2/s±.21×10(-3) vs. 1.77×10(-3) mm2/s±.29×10(-3) for observer 1 and 1.11×10(-3) mm2/s±.19×10(-3) vs. 1.79×10(-3) mm2/s±.32×10(-3) for observer 2) and univariate analysis found significant correlations between lesion type and ADC values. Depending on ADC threshold value, accuracy for the diagnosis of malignant neoplasm varied from 82.9% to 94.3%. Using visual evaluation, FBDW showed better specificity and accuracy than T2WFSE MR images for the diagnosis of malignant neoplasm (97.1% vs. 77.1% and 94.3% vs. 62.9%, respectively). FBDW imaging provides reproducible quantitative information and surpasses the value of T2WFSE MR imaging for differentiating between cavernous hemangiomas and untreated malignant hepatic neoplasms. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  13. Abdominal applications of 3.0-T MR imaging: comparative review versus a 1.5-T system.

    PubMed

    Choi, Jin-Young; Kim, Myeong-Jin; Chung, Yong Eun; Kim, Ji Youn; Jones, Alun C; de Becker, Jan; van Cauteren, Marc

    2008-01-01

    With the development of dedicated receiver coils and increased gradient performance, 3.0-T magnetic resonance (MR) systems are gaining wider acceptance in clinical practice. The expected twofold increase in signal-to-noise ratio (SNR) compared with that of 1.5-T MR systems may help improve spatial resolution or increase temporal resolution when used with parallel acquisition techniques. Several issues must be considered when applying 3.0-T MR in the abdomen, including the alteration of the radiofrequency field and relaxation time, increase in energy deposition and susceptibility effects, and problems associated with motion artifacts. For the evaluation of liver lesions, higher SNR and greater resolution achieved with the 3.0-T system could translate into better detection of malignant lesions on T2-weighted images obtained with adjusted imaging parameters. For the evaluation of pancreatic and biliary diseases, high-resolution T2-weighted imaging using single-shot turbo spin-echo sequences is useful; improvement in SNR was noticeable on two-dimensional MR cholangiopancreatographic images. For the preoperative imaging of rectal cancer, a single-shot sequence is useful for dramatically decreasing imaging time while maintaining image quality. Substantial modification of examination protocols, with optimized imaging parameters and sequence designs along with ongoing development of hardware, could contribute to an increased role of the 3.0-T system for abdominal MR examinations.

  14. Near-infrared light-activated red-emitting upconverting nanoplatform for T1-weighted magnetic resonance imaging and photodynamic therapy.

    PubMed

    Tang, Xiang-Long; Wu, Jun; Lin, Ben-Lan; Cui, Sheng; Liu, Hong-Mei; Yu, Ru-Tong; Shen, Xiao-Dong; Wang, Ting-Wei; Xia, Wei

    2018-05-12

    Photodynamic therapy (PDT) has increasingly become an efficient and attractive cancer treatment modality based on reactive oxygen species (ROS) that can induce tumor death after irradiation with ultraviolet or visible light. Herein, to overcome the limited tissue penetration in traditional PDT, a novel near-infrared (NIR) light-activated NaScF 4 : 40% Yb, 2% Er@CaF 2 upconversion nanoparticle (rUCNP) is successfully designed and synthesized. Chlorin e6, a photosensitizer and a chelating agent for Mn 2+ , is loaded into human serum albumin (HSA) that further conjugates onto rUCNPs. To increase the ability to target glioma tumor, an acyclic Arg-Gly-Asp peptide (cRGDyK) is linked to rUCNPs@HSA(Ce6-Mn). This nanoplatform enables efficient adsorption and conversion of NIR light (980 nm) into bright red emission (660 nm), which can trigger the photosensitizer Ce6-Mn complex for PDT and T 1 -weighted magnetic resonance imaging (T 1 -weighted MRI) for glioma diagnosis. Our in vitro and in vivo experiments demonstrate that NIR light-activated and glioma tumor-targeted PDT can generate large amounts of intracellular ROS that induce U87 cell apoptosis and suppress glioma tumor growth owing to the deep tissue penetration of irradiated light and excellent tumor-targeting ability. Thus, this nanoplatform holds potential for applications in T 1 -weighted MRI diagnosis and PDT of glioma for antitumor therapy. A near-infrared (NIR) light-activated nanoplatform for photodynamic therapy (PDT) was designed and synthesized. The Red-to-Green (R/G) ratio of NaScF 4 : 40% Yb, 2% Er almost reached 9, a value that was much higher than that of a traditional Yb/Er-codoped upconversion nanoparticle (rUCNP). By depositing a CaF 2 shell, the red-emission intensities of the rUCNPs were seven times strong as that of NaScF 4 : 40% Yb, 2% Er. The enhanced red-emitting rUCNPs could be applied in many fields such as bioimaging, controlled release, and real-time diagnosis. The nanoplatform had a

  15. Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence.

    PubMed

    Naganawa, Shinji; Satake, Hiroko; Iwano, Shingo; Kawai, Hisashi; Kubota, Seiji; Komada, Tomohiro; Kawamura, Minako; Sakurai, Yasuo; Fukatsu, Hiroshi

    2008-02-01

    The BLADE and PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) techniques have been proposed to reduce the effect of head motion. Preliminary results have shown that BLADE also reduces pulsation artifacts from venous sinuses. The purpose of this study was to compare T1-weighted FLAIR acquired with BLADE (T1W-FLAIR BLADE) and T1-weighted spin-echo (T1W-SE) for the detection of contrast enhancement in a phantom and in patients with suspected brain lesions and to compare the degree of flow-related artifacts in the patients. A phantom filled with diluted Gd-DTPA was scanned in addition to 27 patients. In the phantom study, the peak contrast-to-noise ratio of T1W-FLAIR BLADE was larger than that of T1W-SE, and the position of the peak was shifted to a lower concentration. In patients, the degree of flow-related artifacts was significantly higher in T1W-SE. Among the 27 patients, 9 had metastatic tumor, and 18 did not. On a patient-by-patient basis, the sensitivity and specificity for the detection of metastatic lesions on axial T1W-SE were 100% and 55.6% respectively, while on axial T1W-FLAIR BLADE they were 100% and 100%. T1W-FLAIR BLADE seems to be capable of replacing T1W-SE, at least for axial post-contrast imaging to detect brain metastases.

  16. Evaluation of multimodal segmentation based on 3D T1-, T2- and FLAIR-weighted images - the difficulty of choosing.

    PubMed

    Lindig, Tobias; Kotikalapudi, Raviteja; Schweikardt, Daniel; Martin, Pascal; Bender, Friedemann; Klose, Uwe; Ernemann, Ulrike; Focke, Niels K; Bender, Benjamin

    2018-04-15

    Voxel-based morphometry is still mainly based on T1-weighted MRI scans. Misclassification of vessels and dura mater as gray matter has been previously reported. Goal of the present work was to evaluate the effect of multimodal segmentation methods available in SPM12, and their influence on identification of age related atrophy and lesion detection in epilepsy patients. 3D T1-, T2- and FLAIR-images of 77 healthy adults (mean age 35.8 years, 19-66 years, 45 females), 7 patients with malformation of cortical development (MCD) (mean age 28.1 years,19-40 years, 3 females), and 5 patients with left hippocampal sclerosis (LHS) (mean age 49.0 years, 25-67 years, 3 females) from a 3T scanner were evaluated. Segmentation based on T1-only, T1+T2, T1+FLAIR, T2+FLAIR, and T1+T2+FLAIR were compared in the healthy subjects. Clinical VBM results based on the different segmentation approaches for MCD and for LHS were compared. T1-only segmentation overestimated total intracranial volume by about 80ml compared to the other segmentation methods. This was due to misclassification of dura mater and vessels as GM and CSF. Significant differences were found for several anatomical regions: the occipital lobe, the basal ganglia/thalamus, the pre- and postcentral gyrus, the cerebellum, and the brainstem. None of the segmentation methods yielded completely satisfying results for the basal ganglia/thalamus and the brainstem. The best correlation with age could be found for the multimodal T1+T2+FLAIR segmentation. Highest T-scores for identification of LHS were found for T1+T2 segmentation, while highest T-scores for MCD were dependent on lesion and anatomical location. Multimodal segmentation is superior to T1-only segmentation and reduces the misclassification of dura mater and vessels as GM and CSF. Depending on the anatomical region and the pathology of interest (atrophy, lesion detection, etc.), different combinations of T1, T2 and FLAIR yield optimal results. Copyright © 2017 Elsevier

  17. Urinary bladder cancer T-staging from T2-weighted MR images using an optimal biomarker approach

    NASA Astrophysics Data System (ADS)

    Wang, Chuang; Udupa, Jayaram K.; Tong, Yubing; Chen, Jerry; Venigalla, Sriram; Odhner, Dewey; Guzzo, Thomas J.; Christodouleas, John; Torigian, Drew A.

    2018-02-01

    Magnetic resonance imaging (MRI) is often used in clinical practice to stage patients with bladder cancer to help plan treatment. However, qualitative assessment of MR images is prone to inaccuracies, adversely affecting patient outcomes. In this paper, T2-weighted MR image-based quantitative features were extracted from the bladder wall in 65 patients with bladder cancer to classify them into two primary tumor (T) stage groups: group 1 - T stage < T2, with primary tumor locally confined to the bladder, and group 2 - T stage < T2, with primary tumor locally extending beyond the bladder. The bladder was divided into 8 sectors in the axial plane, where each sector has a corresponding reference standard T stage that is based on expert radiology qualitative MR image review and histopathologic results. The performance of the classification for correct assignment of T stage grouping was then evaluated at both the patient level and the sector level. Each bladder sector was divided into 3 shells (inner, middle, and outer), and 15,834 features including intensity features and texture features from local binary pattern and gray-level co-occurrence matrix were extracted from the 3 shells of each sector. An optimal feature set was selected from all features using an optimal biomarker approach. Nine optimal biomarker features were derived based on texture properties from the middle shell, with an area under the ROC curve of AUC value at the sector and patient level of 0.813 and 0.806, respectively.

  18. T1ρ magnetic resonance: basic physics principles and applications in knee and intervertebral disc imaging

    PubMed Central

    Zhang, Qinwei; Li, Xiaojuan; Chen, Weitian; Ahuja, Anil; Yuan, Jing

    2015-01-01

    T1ρ relaxation time provides a new contrast mechanism that differs from T1- and T2-weighted contrast, and is useful to study low-frequency motional processes and chemical exchange in biological tissues. T1ρ imaging can be performed in the forms of T1ρ-weighted image, T1ρ mapping and T1ρ dispersion. T1ρ imaging, particularly at low spin-lock frequency, is sensitive to B0 and B1 inhomogeneity. Various composite spin-lock pulses have been proposed to alleviate the influence of field inhomogeneity so as to reduce the banding-like spin-lock artifacts. T1ρ imaging could be specific absorption rate (SAR) intensive and time consuming. Efforts to address these issues and speed-up data acquisition are being explored to facilitate wider clinical applications. This paper reviews the T1ρ imaging’s basic physic principles, as well as its application for cartilage imaging and intervertebral disc imaging. Compared to more established T2 relaxation time, it has been shown that T1ρ provides more sensitive detection of proteoglycan (PG) loss at early stages of cartilage degeneration. T1ρ has also been shown to provide more sensitive evaluation of annulus fibrosis (AF) degeneration of the discs. PMID:26807369

  19. Diagnostic Utility of Contrast-enhanced 3D T1-weighted Imaging in Acute Cerebral Infarction Associated with Graves Disease.

    PubMed

    Gon, Yasufumi; Sakaguchi, Manabu; Oyama, Naoki; Mochizuki, Hideki

    2017-02-01

    Graves disease is rarely complicated with cerebrovascular steno-occlusive diseases. Previous studies have suggested several hypotheses for this occurrence, including excess thyroid hormone, which stimulates the sympathetic nervous system, which in turn causes an abnormal hemodynamic response with consequent atherosclerotic changes, and antithyroid antibodies cause local vascular inflammation in patients with Graves disease. However, radiological findings of vasculitis in patients with Graves disease and cerebral infarction remain less known. We report the case of a 30-year-old Japanese woman with acute cerebral infarction due to vasculitis associated with Graves disease. She was admitted to our hospital with a 4-day history of intermittent transient dysarthria and limb shaking of the left leg when standing. Three weeks before admission, she went to a local hospital because of general malaise and was diagnosed with Graves disease. Neurological examination revealed paralytic dysarthria, left central facial nerve palsy, and left hemiparesis (manual muscle testing, 4 of 5). Blood examinations showed hyperthyroidism (thyroid-stimulating hormone ≤.010 µU/mL; free T3 ≥25.0 pg/mL; free T4 ≥8.0 ng/dL) and elevation of antithyroid antibody levels (thyroid peroxidase antibody, 87 IU/mL). The vessel wall of the right internal carotid artery was markedly enhanced on contrast-enhanced three-dimensional T1-weighted magnetic resonance imaging, suggesting vasculitis. Magnetic resonance angiography revealed right internal carotid artery occlusion after the branching ophthalmic artery. Arterial stenosis due to vasculitis was considered the cause of hemodynamic ischemic stroke. Vessel wall imaging such as high-resolution contrast-enhanced T1-weighted imaging seems useful for assessing the underlying mechanism of stroke in patients with Graves disease. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  20. SU-E-J-157: Improving the Quality of T2-Weighted 4D Magnetic Resonance Imaging for Clinical Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Du, D; Mutic, S; Hu, Y

    2014-06-01

    Purpose: To develop an imaging technique that enables us to acquire T2- weighted 4D Magnetic Resonance Imaging (4DMRI) with sufficient spatial coverage, temporal resolution and spatial resolution for clinical evaluation. Methods: T2-weighed 4DMRI images were acquired from a healthy volunteer using a respiratory amplitude triggered T2-weighted Turbo Spin Echo sequence. 10 respiratory states were used to equally sample the respiratory range based on amplitude (0%, 20%i, 40%i, 60%i, 80%i, 100%, 80%e, 60%e, 40%e and 20%e). To avoid frequent scanning halts, a methodology was devised that split 10 respiratory states into two packages in an interleaved manner and packages were acquiredmore » separately. Sixty 3mm sagittal slices at 1.5mm in-plane spatial resolution were acquired to offer good spatial coverage and reasonable spatial resolution. The in-plane field of view was 375mm × 260mm with nominal scan time of 3 minutes 42 seconds. Acquired 2D images at the same respiratory state were combined to form the 3D image set corresponding to that respiratory state and reconstructed in the coronal view to evaluate whether all slices were at the same respiratory state. 3D image sets of 10 respiratory states represented a complete 4D MRI image set. Results: T2-weighted 4DMRI image were acquired in 10 minutes which was within clinical acceptable range. Qualitatively, the acquired MRI images had good image quality for delineation purposes. There were no abrupt position changes in reconstructed coronal images which confirmed that all sagittal slices were in the same respiratory state. Conclusion: We demonstrated it was feasible to acquire T2-weighted 4DMRI image set within a practical amount of time (10 minutes) that had good temporal resolution (10 respiratory states), spatial resolution (1.5mm × 1.5mm × 3.0mm) and spatial coverage (60 slices) for future clinical evaluation.« less

  1. IVIM diffusion-weighted imaging of the liver at 3.0 T: Comparison with 1.5 T

    PubMed Central

    Cui, Yong; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Taouli, Bachir

    2015-01-01

    Purpose To compare intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver between 1.5 T and 3.0 T in terms of parameter quantification and inter-platform reproducibility. Materials and methods In this IRB approved prospective study, 19 subjects (17 patients with chronic liver disease and 2 healthy volunteers) underwent two repeat scans at 1.5 T and 3.0 T. Each scan included IVIM DWI using 16 b values from 0 to 800 s/mm2. A single observer measured IVIM parameters for each platform and estimated signal to noise ratio (eSNR) at b0, 200, 400 and 800 s/mm2. Wilcoxon paired tests were used to compare liver eSNR and IVIM parameters. Inter-platform reproducibility was assessed by calculating within-subject coefficient of variation (CV) and Bland–Altman limits of agreement. An ice water phantom was used to test ADC variability between the two MRI systems. Results The mean invitro difference in ADC between the two platforms was 6.8%. eSNR was significantly higher at 3.0T for all selected b values (p = 0.006–0.020), except for b0 (p = 0.239). Liver IVIM parameters were significantly different between 1.5 T and 3.0 T (p = 0.005–0.044), except for ADC (p = 0.748). The inter-platform reproducibility of true diffusion coefficient (D) and ADC were good, with mean CV of 10.9% and 11.1%, respectively. Perfusion fraction (PF) and pseudodiffusion coefficient (D*) showed more limited inter-platform reproducibility (mean CV of 22.6% for PF and 46.9% for D*). Conclusion Liver D and ADC values showed good reproducibility between 1.5 T and 3.0 T platforms; while there was more variability in PF, and large variability in D* parameters between the two platforms. These findings may have implications for drug trials assessing the role of IVIM DWI in tumor response and liver fibrosis. PMID:26393236

  2. Clinical Feasibility of Free-Breathing Dynamic T1-Weighted Imaging With Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging Using a Combination of Variable Density Sampling and Compressed Sensing.

    PubMed

    Yoon, Jeong Hee; Yu, Mi Hye; Chang, Won; Park, Jin-Young; Nickel, Marcel Dominik; Son, Yohan; Kiefer, Berthold; Lee, Jeong Min

    2017-10-01

    The purpose of the study was to investigate the clinical feasibility of free-breathing dynamic T1-weighted imaging (T1WI) using Cartesian sampling, compressed sensing, and iterative reconstruction in gadoxetic acid-enhanced liver magnetic resonance imaging (MRI). This retrospective study was approved by our institutional review board, and the requirement for informed consent was waived. A total of 51 patients at high risk of breath-holding failure underwent dynamic T1WI in a free-breathing manner using volumetric interpolated breath-hold (BH) examination with compressed sensing reconstruction (CS-VIBE) and hard gating. Timing, motion artifacts, and image quality were evaluated by 4 radiologists on a 4-point scale. For patients with low image quality scores (<3) on the late arterial phase, respiratory motion-resolved (extradimension [XD]) reconstruction was additionally performed and reviewed in the same manner. In addition, in 68.6% (35/51) patients who had previously undergone liver MRI, image quality and motion artifacts on dynamic phases using CS-VIBE were compared with previous BH-T1WIs. In all patients, adequate arterial-phase timing was obtained at least once. Overall image quality of free-breathing T1WI was 3.30 ± 0.59 on precontrast and 2.68 ± 0.70, 2.93 ± 0.65, and 3.30 ± 0.49 on early arterial, late arterial, and portal venous phases, respectively. In 13 patients with lower than average image quality (<3) on the late arterial phase, motion-resolved reconstructed T1WI (XD-reconstructed CS-VIBE) significantly reduced motion artifacts (P < 0.002-0.021) and improved image quality (P < 0.0001-0.002). In comparison with previous BH-T1WI, CS-VIBE with hard gating or XD reconstruction showed less motion artifacts and better image quality on precontrast, arterial, and portal venous phases (P < 0.0001-0.013). Volumetric interpolated breath-hold examination with compressed sensing has the potential to provide consistent, motion-corrected free-breathing dynamic T

  3. Evaluation of Image Quality in Three-dimensional Fat-suppressed T1-weighted Images with Fast Acquisition Mode for Upper Abdomen.

    PubMed

    Saito, Shigeyoshi; Tanaka, Keiko; Tarewaki, Hiroyuki; Koyama, Yoshihiro; Hashido, Takashi

    2016-01-01

    We compared the uniformity of fat-suppression and image quality using three-dimensional fat-suppressed T 1 -weighted gradient-echo sequences that are liver acquisition with volume acceleration (LAVA) and Turbo-LAVA at 3.0T-MRI. The subjects were seven patients with liver disease (mean age, 66.7±8.2 years). The axial slices of two LAVA sequences were used for the comparison of the uniformity of fat-suppression and image quality at a region-of-interest (ROI) of the liver dome, the porta, and the renal hilum. To yield a quantitative measurement of the uniformity of fat suppression, the percentage standard deviation (%SD) was calculated by comparing two sequences. For image signal to noise ratio (SNR), the contrast between the liver and fat (C liver-fat ), and the liver and muscle (C liver-muscle ), the other ROIs were placed in the superficial fat, liver, spleen, pancreas, and muscle. The %SD in Turbo-LAVA (28.1±16.8%) was lower than that in LAVA (41.5±13.4%). The SNRs in Turbo-LAVA (17.8±4.1 [liver], 12.5±3.0 [pancreas], 14.7±1.6 [spleen], 8.2±3.5 [fat]) were lower than those in LAVA (20.9±6.1 [liver], 16.8±4.1 [pancreas], 17.4±2.4 [spleen], 12.0±4.5 [fat]). While, the C liver-fat in the Turbo-LAVA (0.72±0.06) was significantly higher than that in LAVA (0.59±0.07). Turbo-LAVA sequence offers superior and more homogenous fat-suppression in comparison to LAVA sequence.

  4. Individual T1-weighted/T2-weighted ratio brain networks: Small-worldness, hubs and modular organization

    NASA Astrophysics Data System (ADS)

    Wu, Huijun; Wang, Hao; Lü, Linyuan

    Applying network science to investigate the complex systems has become a hot topic. In neuroscience, understanding the architectures of complex brain networks was a vital issue. An enormous amount of evidence had supported the brain was cost/efficiency trade-off with small-worldness, hubness and modular organization through the functional MRI and structural MRI investigations. However, the T1-weighted/T2-weighted (T1w/T2w) ratio brain networks were mostly unexplored. Here, we utilized a KL divergence-based method to construct large-scale individual T1w/T2w ratio brain networks and investigated the underlying topological attributes of these networks. Our results supported that the T1w/T2w ratio brain networks were comprised of small-worldness, an exponentially truncated power-law degree distribution, frontal-parietal hubs and modular organization. Besides, there were significant positive correlations between the network metrics and fluid intelligence. Thus, the T1w/T2w ratio brain networks open a new avenue to understand the human brain and are a necessary supplement for future MRI studies.

  5. Non-contrast magnetic resonance imaging for bladder cancer: fused high b value diffusion-weighted imaging and T2-weighted imaging helps evaluate depth of invasion.

    PubMed

    Lee, Minsu; Shin, Su-Jin; Oh, Young Taik; Jung, Dae Chul; Cho, Nam Hoon; Choi, Young Deuk; Park, Sung Yoon

    2017-09-01

    To investigate the utility of fused high b value diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) for evaluating depth of invasion in bladder cancer. We included 62 patients with magnetic resonance imaging (MRI) and surgically confirmed urothelial carcinoma in the urinary bladder. An experienced genitourinary radiologist analysed the depth of invasion (T stage <2 or ≥2) using T2WI, DWI, T2WI plus DWI, and fused DWI and T2WI (fusion MRI). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were investigated. Area under the curve (AUC) was analysed to identify T stage ≥2. The rate of patients with surgically confirmed T stage ≥2 was 41.9% (26/62). Sensitivity, specificity, PPV, NPV and accuracy were 50.0%, 55.6%, 44.8%, 60.6% and 53.2%, respectively, with T2WI; 57.7%, 77.8%, 65.2%, 71.8% and 69.4%, respectively, with DWI; 65.4%, 80.6%, 70.8%, 76.3% and 74.2%, respectively, with T2WI plus DWI and 80.8%, 77.8%, 72.4%, 84.9% and 79.0%, respectively, with fusion MRI. AUC was 0.528 with T2WI, 0.677 with DWI, 0.730 with T2WI plus DWI and 0.793 with fusion MRI for T stage ≥2. Fused high b value DWI and T2WI may be a promising non-contrast MRI technique for assessing depth of invasion in bladder cancer. • Accuracy of fusion MRI was 79.0% for T stage ≥2 in bladder cancer. • AUC of fusion MRI was 0.793 for T stage ≥2 in bladder cancer. • Diagnostic performance of fusion MRI was comparable with T2WI plus DWI. • As a non-contrast MRI technique, fusion MRI is useful for bladder cancer.

  6. Body weight lower limits of fetal postmortem MRI at 1.5 T.

    PubMed

    Jawad, N; Sebire, N J; Wade, A; Taylor, A M; Chitty, L S; Arthurs, O J

    2016-07-01

    To evaluate the diagnostic yield of postmortem magnetic resonance imaging (PM-MRI) compared with conventional autopsy in fetuses of early gestational age and low body weight. Fetuses of < 31 weeks' gestation that underwent 1.5-T PM-MRI and conventional autopsy were included. The findings of PM-MRI and conventional autopsy were reported blinded to each other. The reports of conventional autopsy and PM-MRI for each organ system (cardiovascular, neurological, abdominal, non-cardiac thoracic and musculoskeletal) were classified as either diagnostic or non-diagnostic. The likelihood of a non-diagnostic examination by PM-MRI was calculated according to fetal gestational age and body weight. Full datasets were examined of 204 fetuses, with mean gestational age of 20.95 ± 3.82 weeks (range, 12.0-30.7 weeks) and body-weight range of 15.9-1872 g. Body weight was the most significant predictor of diagnostic yield of PM-MRI. There was 95% confidence that 90% of fetuses will show diagnostic images by PM-MRI for all five organ systems when fetal body weight is ≥ 535 g, but < 50% of fetuses will have all five systems diagnostic on PM-MRI when body weight is < 122 g. PM-MRI is highly likely to provide adequate diagnostic images for fetuses with a body weight > 500 g. Below this weight, the diagnostic yield of standard 1.5-T PM-MRI decreases significantly. These data should help inform parents and clinicians on the suitability of performing PM-MRI in fetuses with low body weight. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  7. Accuracy for detection of simulated lesions: comparison of fluid-attenuated inversion-recovery, proton density--weighted, and T2-weighted synthetic brain MR imaging

    NASA Technical Reports Server (NTRS)

    Herskovits, E. H.; Itoh, R.; Melhem, E. R.

    2001-01-01

    OBJECTIVE: The objective of our study was to determine the effects of MR sequence (fluid-attenuated inversion-recovery [FLAIR], proton density--weighted, and T2-weighted) and of lesion location on sensitivity and specificity of lesion detection. MATERIALS AND METHODS: We generated FLAIR, proton density-weighted, and T2-weighted brain images with 3-mm lesions using published parameters for acute multiple sclerosis plaques. Each image contained from zero to five lesions that were distributed among cortical-subcortical, periventricular, and deep white matter regions; on either side; and anterior or posterior in position. We presented images of 540 lesions, distributed among 2592 image regions, to six neuroradiologists. We constructed a contingency table for image regions with lesions and another for image regions without lesions (normal). Each table included the following: the reviewer's number (1--6); the MR sequence; the side, position, and region of the lesion; and the reviewer's response (lesion present or absent [normal]). We performed chi-square and log-linear analyses. RESULTS: The FLAIR sequence yielded the highest true-positive rates (p < 0.001) and the highest true-negative rates (p < 0.001). Regions also differed in reviewers' true-positive rates (p < 0.001) and true-negative rates (p = 0.002). The true-positive rate model generated by log-linear analysis contained an additional sequence-location interaction. The true-negative rate model generated by log-linear analysis confirmed these associations, but no higher order interactions were added. CONCLUSION: We developed software with which we can generate brain images of a wide range of pulse sequences and that allows us to specify the location, size, shape, and intrinsic characteristics of simulated lesions. We found that the use of FLAIR sequences increases detection accuracy for cortical-subcortical and periventricular lesions over that associated with proton density- and T2-weighted sequences.

  8. Diagnostic value of brain chronic black holes on T1-weighted MR images in clinically isolated syndromes.

    PubMed

    Mitjana, Raquel; Tintoré, Mar; Rocca, Maria A; Auger, Cristina; Barkhof, Frederik; Filippi, Massimo; Polman, Chris; Fazekas, Franz; Huerga, Elena; Montalban, Xavier; Rovira, Alex

    2014-10-01

    Non-enhancing black holes (neBHs) are more common in multiple sclerosis (MS) patients with longer disease durations and progressive disease subtypes. Our aim was to analyse the added value of neBHs in patients with clinically isolated syndromes (CISs) for predicting conversion to clinically definite MS (CDMS). Patients were classified based on the presence or absence of neBHs and on the number of Barkhof-Tintoré (B-T) criteria fulfilled. Dissemination in space (DIS) was defined as the presence of at least three of the four B-T criteria. Dissemination in time (DIT)1 was defined by simultaneous presence of enhancing and non-enhancing lesions. DIT2 was defined by simultaneous presence of neBHs and T2 lesions not apparent on T1-weighted images. Focal T2-hyperintense brain lesions were identified in 87.7% of the 520 CIS patients, and 41.4% of them presented at least one neBH. Patients meeting DIS, DIT1, and DIT2 had a significantly higher rate of conversion to CDMS. After adjusting for DIS, only patients who fulfilled DIT1 preserved a significant increase in CDMS conversion. Non-enhancing black holes in CIS patients are associated with a higher risk of conversion to CDMS. However, the predictive value of this finding is lost when added to the DIS criteria. © The Author(s) 2014.

  9. T1-weighted dynamic contrast-enhanced brain magnetic resonance imaging: A preliminary study with low infusion rate in pediatric patients.

    PubMed

    Rochetams, Bruno-Bernard; Marechal, Bénédicte; Cottier, Jean-Philippe; Gaillot, Kathleen; Sembely-Taveau, Catherine; Sirinelli, Dominique; Morel, Baptiste

    2017-10-01

    Background The aim of this preliminary study is to evaluate the results of T1-weighted dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) in pediatric patients at 1.5T, with a low peripheral intravenous gadoteric acid injection rate of 1 ml/s. Materials and methods Children with neurological symptoms were examined prospectively with conventional MRI and T1-weighted DCE MRI. An magnetic resonance perfusion analysis method was used to obtain time-concentration curves (persistent pattern, type-I; plateau pattern, type-II; washout pattern, type-III) and to calculate pharmacokinetic parameters. A total of two radiologists manually defined regions of interest (ROIs) in the part of the lesion exhibiting the greatest contrast enhancement and in the surrounding normal or contralateral tissue. Lesion/surrounding tissue or contralateral tissue pharmacokinetic parameter ratios were calculated. Tumors were categorized by grade (I-IV) using the World Health Organization (WHO) Grade. Mann-Whitney testing and receiver-operating characteristic (ROC) curves were performed. Results A total of nine boys and nine girls (mean age 10.5 years) were included. Lesions consisted of 10 brain tumors, 3 inflammatory lesions, 3 arteriovenous malformations and 2 strokes. We obtained analyzable concentration-time curves for all patients (6 type-I, 9 type-II, 3 type-III). K trans between tumor tissue and surrounding or contralateral tissue was significantly different ( p = 0.034). K trans ratios were significantly different between grade I tumors and grade IV tumors ( p = 0.027) and a K trans ratio value superior to 0.63 appeared to be discriminant to determine a grade IV of malignancy. Conclusions Our results confirm the feasibility of pediatric T1-weighted DCE MRI at 1.5T with a low injection rate, which could be of great value in differentiating brain tumor grades.

  10. Development of PEGylated KMnF3 nanoparticles as a T1-weighted contrast agent: chemical synthesis, in vivo brain MR imaging, and accounting for high relaxivity

    NASA Astrophysics Data System (ADS)

    Liu, Zhi-Jun; Song, Xiao-Xia; Tang, Qun

    2013-05-01

    Magnetic nanoparticles consisting of manganese-based T1-weighted contrast agents have rapidly achieved clinical application, however low proton relaxivity impedes further development. In this report, by analyzing nanoparticles' surface oxidation states we propose the possible reason for the low r1 relaxivity of common MnO nanoparticles and develop PEGylated fluoroperovskite KMnF3 nanoparticles as new T1-weighted contrast agents, which exhibit the highest longitudinal relaxivity (r1 = 23.15 mM-1 s-1) among all the reported manganese-based T1-weighted contrast agents. We, for the first time, illustrate a typical example showing that the surface oxidation states of metal ions exposed on the nanoparticles' surfaces are able to influence not only the optical, magnetic, electronic or catalytic properties but also water proton longitudinal relaxivity when applied as an MRI contrast agent. Cytotoxicity tests demonstrate that the PEGylated KMnF3 nanoparticles are free from toxicity. Further in vivo MRI experiments distinctively depict fine anatomical features in brain imaging at a low dose of 5 mg of Mn per kg and possible removal from the kidneys due to their small size and biocompatibility.Magnetic nanoparticles consisting of manganese-based T1-weighted contrast agents have rapidly achieved clinical application, however low proton relaxivity impedes further development. In this report, by analyzing nanoparticles' surface oxidation states we propose the possible reason for the low r1 relaxivity of common MnO nanoparticles and develop PEGylated fluoroperovskite KMnF3 nanoparticles as new T1-weighted contrast agents, which exhibit the highest longitudinal relaxivity (r1 = 23.15 mM-1 s-1) among all the reported manganese-based T1-weighted contrast agents. We, for the first time, illustrate a typical example showing that the surface oxidation states of metal ions exposed on the nanoparticles' surfaces are able to influence not only the optical, magnetic, electronic or

  11. Advantages of T2 Weighted Three Dimensional and T1 Weighted Three Dimensional Contrast Medium Enhanced Magnetic Resonance Urography in Examination of the Child Population.

    PubMed

    Sehic, Adnan; Julardzija, Fuad; Vegar-Zubovic, Sandra; Sefic-Pasic, Irmina

    2017-03-01

    The aim of this study is to prove the advantages of combined use of T2 weighted three dimensional (T2 W 3D) and T1 weighted three dimensional contrast medium enhanced (T1 W 3D CE) magnetic resonance (MR) urography in displaying urinary tract in child population. Total of 120 patients were included in the study, 71 (59%) male patients and 49 (41%) female patients. The study was conducted on the Radiology clinic, University of Sarajevo Clinical Center, during the period from February to November 2016. Patients were examined on the 1.5T and 3T MRI, with standard protocol which includes T2 W 3D and T1 W 3D contrast medium enhanced MR urography. In the post procesing quantitative measurement of signal intensity and evaluation of the display quality in the area of renal pelvis, middle of ureter and the mouth of the ureter were done. Measurement was concluded on Syngo software B13. Analyzing the acquired data and statistically processing them we got results which have shown higher signal intensity of measured structures on T1 W 3D contrast medium enhanced MR urography on the level p<0.01 and p<0.05 compared to T2 W 3D MR urography in patients that had normal dynamics of contrast medium secretion. However, in kidneys with decreased function, T2 W 3D MR urography provided higher signal intensity and better display compared to T1 W 3D contrast medium enhanced MR urography on the level p<0.05 and p<0.01. T2 W3D MR urography is useful in imaging nonfunctional kidney as well as in patients prone to allergic reactions, where as T1 W3D CE MR urography is at an advantage over T2 W 3D MR urography in imaging the kidney functionality, kidney dynamics measurement, it provides higher MRI signal intensity required for clear 3D reconstructions.

  12. High-Quality T2-Weighted 4-Dimensional Magnetic Resonance Imaging for Radiation Therapy Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Du, Dongsu; Caruthers, Shelton D.; Glide-Hurst, Carri

    2015-06-01

    Purpose: The purpose of this study was to improve triggering efficiency of the prospective respiratory amplitude-triggered 4-dimensional magnetic resonance imaging (4DMRI) method and to develop a 4DMRI imaging protocol that could offer T2 weighting for better tumor visualization, good spatial coverage and spatial resolution, and respiratory motion sampling within a reasonable amount of time for radiation therapy applications. Methods and Materials: The respiratory state splitting (RSS) and multi-shot acquisition (MSA) methods were analytically compared and validated in a simulation study by using the respiratory signals from 10 healthy human subjects. The RSS method was more effective in improving triggering efficiency.more » It was implemented in prospective respiratory amplitude-triggered 4DMRI. 4DMRI image datasets were acquired from 5 healthy human subjects. Liver motion was estimated using the acquired 4DMRI image datasets. Results: The simulation study showed the RSS method was more effective for improving triggering efficiency than the MSA method. The average reductions in 4DMRI acquisition times were 36% and 10% for the RSS and MSA methods, respectively. The human subject study showed that T2-weighted 4DMRI with 10 respiratory states, 60 slices at a spatial resolution of 1.5 × 1.5 × 3.0 mm{sup 3} could be acquired in 9 to 18 minutes, depending on the individual's breath pattern. Based on the acquired 4DMRI image datasets, the ranges of peak-to-peak liver displacements among 5 human subjects were 9.0 to 12.9 mm, 2.5 to 3.9 mm, and 0.5 to 2.3 mm in superior-inferior, anterior-posterior, and left-right directions, respectively. Conclusions: We demonstrated that with the RSS method, it was feasible to acquire high-quality T2-weighted 4DMRI within a reasonable amount of time for radiation therapy applications.« less

  13. Breast Lesions: Diagnosis Using Diffusion Weighted Imaging at 1.5T and 3.0T-Systematic Review and Meta-analysis.

    PubMed

    Shi, Ruo-Yang; Yao, Qiu-Ying; Wu, Lian-Ming; Xu, Jian-Rong

    2018-06-01

    We compared the diagnostic performance of diffusion weighted imaging (DWI) acquired with 1.5T and 3.0T magnetic resonance (MR) units in differentiating malignant breast lesions from benign ones. A comprehensive search of the PubMed and Embase databases was performed for studies reported from January 1, 2000 to February 19, 2016. The quality of the included studies was assessed. Statistical analysis included pooling of diagnostic sensitivity and specificity and assessing data inhomogeneity and publication bias. A total of 61 studies were included after a full-text review. These included 4778 patients and 5205 breast lesions. The overall sensitivity and specificity were 90% (95% confidence interval [CI], 88%-92%) and 86% (95% CI, 82%-89%), respectively. The pooled diagnostic odds ratio was 53 (95% CI, 37-74). For breast cancer versus benign lesions, the area under the curve was 0.94 (95% CI, 0.92-0.96). For the 44 studies that used a 1.5T MR unit, the pooled sensitivity and specificity were 91% (95% CI, 89%-92%) and 86% (95% CI, 81%-90%), respectively. For the 17 studies that used a 3.0T MR unit, the pooled sensitivity and specificity were 88% (95% CI, 83%-91%) and 84% (95% CI, 0.78-0.89), respectively. Publication bias and significant heterogeneity were observed; however, no threshold was found among the 61 studies. No significant difference was found in the sensitivity or specificity between the subgroups. The results of the comparison between the subgroups that had used either a 1.5T or 3.0T MR unit suggest that the diagnostic accuracy for breast cancer compared with benign lesions is not significantly different. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Quantitative T1 and T2* carotid atherosclerotic plaque imaging using a three-dimensional multi-echo phase-sensitive inversion recovery sequence: a feasibility study.

    PubMed

    Fujiwara, Yasuhiro; Maruyama, Hirotoshi; Toyomaru, Kanako; Nishizaka, Yuri; Fukamatsu, Masahiro

    2018-06-01

    Magnetic resonance imaging (MRI) is widely used to detect carotid atherosclerotic plaques. Although it is important to evaluate vulnerable carotid plaques containing lipids and intra-plaque hemorrhages (IPHs) using T 1 -weighted images, the image contrast changes depending on the imaging settings. Moreover, to distinguish between a thrombus and a hemorrhage, it is useful to evaluate the iron content of the plaque using both T 1 -weighted and T 2 *-weighted images. Therefore, a quantitative evaluation of carotid atherosclerotic plaques using T 1 and T 2 * values may be necessary for the accurate evaluation of plaque components. The purpose of this study was to determine whether the multi-echo phase-sensitive inversion recovery (mPSIR) sequence can improve T 1 contrast while simultaneously providing accurate T 1 and T 2 * values of an IPH. T 1 and T 2 * values measured using mPSIR were compared to values from conventional methods in phantom and in vivo studies. In the phantom study, the T 1 and T 2 * values estimated using mPSIR were linearly correlated with those of conventional methods. In the in vivo study, mPSIR demonstrated higher T 1 contrast between the IPH phantom and sternocleidomastoid muscle than the conventional method. Moreover, the T 1 and T 2 * values of the blood vessel wall and sternocleidomastoid muscle estimated using mPSIR were correlated with values measured by conventional methods and with values reported previously. The mPSIR sequence improved T 1 contrast while simultaneously providing accurate T 1 and T 2 * values of the neck region. Although further study is required to evaluate the clinical utility, mPSIR may improve carotid atherosclerotic plaque detection and provide detailed information about plaque components.

  15. Fast T2*-weighted MRI of the prostate at 3 Tesla.

    PubMed

    Hardman, Rulon L; El-Merhi, Fadi; Jung, Adam J; Ware, Steve; Thompson, Ian M; Friel, Harry T; Peng, Qi

    2011-04-01

    To describe a rapid T2*-weighted (T2*W), three-dimensional (3D) echo planar imaging (EPI) sequence and its application in mapping local magnetic susceptibility variations in 3 Tesla (T) prostate MRI. To compare the sensitivity of T2*W EPI with routinely used T1-weighted turbo-spin echo sequence (T1W TSE) in detecting hemorrhage and the implications on sequences sensitive to field inhomogeneities such as MR spectroscopy (MRS). B(0) susceptibility weighted mapping was performed using a 3D EPI sequence featuring a 2D spatial excitation pulse with gradients of spiral k-space trajectory. A series of 11 subjects were imaged using 3T MRI and combination endorectal (ER) and six-channel phased array cardiac coils. T1W TSE and T2*W EPI sequences were analyzed quantitatively for hemorrhage contrast. Point resolved spectroscopy (PRESS MRS) was performed and data quality was analyzed. Two types of susceptibility variation were identified: hemorrhagic and nonhemorrhagic T2*W-positive areas. Post-biopsy hemorrhage lesions showed on average five times greater contrast on the T2*W images than T1W TSE images. Six nonhemorrhage regions of severe susceptibility artifact were apparent on the T2*W images that were not seen on standard T1W or T2W images. All nonhemorrhagic susceptibility artifact regions demonstrated compromised spectral quality on 3D MRS. The fast T2*W EPI sequence identifies hemorrhagic and nonhemorrhagic areas of susceptibility variation that may be helpful in prostate MRI planning at 3.0T. Copyright © 2011 Wiley-Liss, Inc.

  16. T2*-based MR imaging (gradient echo or susceptibility-weighted imaging) in midline and off-midline intracranial germ cell tumors: a pilot study.

    PubMed

    Morana, Giovanni; Alves, Cesar Augusto; Tortora, Domenico; Finlay, Jonathan L; Severino, Mariasavina; Nozza, Paolo; Ravegnani, Marcello; Pavanello, Marco; Milanaccio, Claudia; Maghnie, Mohamad; Rossi, Andrea; Garrè, Maria Luisa

    2018-01-01

    The role of T2*-based MR imaging in intracranial germ cell tumors (GCTs) has not been fully elucidated. The aim of this study was to evaluate the susceptibility-weighted imaging (SWI) or T2* gradient echo (GRE) features of germinomas and non-germinomatous germ cell tumors (NGGCTs) in midline and off-midline locations. We retrospectively evaluated all consecutive pediatric patients referred to our institution between 2005 and 2016, for newly diagnosed, treatment-naïve intracranial GCT, who underwent MRI, including T2*-based MR imaging (T2* GRE sequences or SWI). Standard pre- and post-contrast T1- and T2-weighted imaging characteristics along with T2*-based MR imaging features of all lesions were evaluated. Diagnosis was performed in accordance with the SIOP CNS GCT protocol criteria. Twenty-four subjects met the inclusion criteria (17 males and 7 females). There were 17 patients with germinomas, including 5 basal ganglia primaries, and 7 patients with secreting NGGCT. All off-midline germinomas presented with SWI or GRE hypointensity; among midline GCT, all NGGCTs showed SWI or GRE hypointensity whereas all but one pure germinoma were isointense or hyperintense to normal parenchyma. A significant difference emerged on T2*-based MR imaging among midline germinomas, NGGCTs, and off-midline germinomas (p < 0.001). Assessment of the SWI or GRE characteristics of intracranial GCT may potentially assist in differentiating pure germinomas from NGGCT and in the characterization of basal ganglia involvement. T2*-based MR imaging is recommended in case of suspected intracranial GCT.

  17. Automated image quality evaluation of T2 -weighted liver MRI utilizing deep learning architecture.

    PubMed

    Esses, Steven J; Lu, Xiaoguang; Zhao, Tiejun; Shanbhogue, Krishna; Dane, Bari; Bruno, Mary; Chandarana, Hersh

    2018-03-01

    To develop and test a deep learning approach named Convolutional Neural Network (CNN) for automated screening of T 2 -weighted (T 2 WI) liver acquisitions for nondiagnostic images, and compare this automated approach to evaluation by two radiologists. We evaluated 522 liver magnetic resonance imaging (MRI) exams performed at 1.5T and 3T at our institution between November 2014 and May 2016 for CNN training and validation. The CNN consisted of an input layer, convolutional layer, fully connected layer, and output layer. 351 T 2 WI were anonymized for training. Each case was annotated with a label of being diagnostic or nondiagnostic for detecting lesions and assessing liver morphology. Another independently collected 171 cases were sequestered for a blind test. These 171 T 2 WI were assessed independently by two radiologists and annotated as being diagnostic or nondiagnostic. These 171 T 2 WI were presented to the CNN algorithm and image quality (IQ) output of the algorithm was compared to that of two radiologists. There was concordance in IQ label between Reader 1 and CNN in 79% of cases and between Reader 2 and CNN in 73%. The sensitivity and the specificity of the CNN algorithm in identifying nondiagnostic IQ was 67% and 81% with respect to Reader 1 and 47% and 80% with respect to Reader 2. The negative predictive value of the algorithm for identifying nondiagnostic IQ was 94% and 86% (relative to Readers 1 and 2). We demonstrate a CNN algorithm that yields a high negative predictive value when screening for nondiagnostic T 2 WI of the liver. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:723-728. © 2017 International Society for Magnetic Resonance in Medicine.

  18. Stimulated echo diffusion tensor imaging and SPAIR T2-weighted imaging in Chronic Exertional Compartment Syndrome of the lower leg muscles

    PubMed Central

    Sigmund, Eric E.; Sui, Dabang; Ukpebor, Obehi; Baete, Steven; Fieremans, Els; Babb, James S.; Mechlin, Michael; Liu, Kecheng; Kwon, Jane; Mcgorty, KellyAnne; Hodnett, Phil; Bencardino, Jenny

    2013-01-01

    Purpose To evaluate the performance of diffusion tensor imaging (DTI) in the evaluation of chronic exertional compartment syndrome (CECS) as compared to T2-weighted imaging. Materials and Methods Using an IRB-approved HIPAA-compliant protocol, spectral adiabatic inversion recovery (SPAIR) T2-weighted imaging (T2w) and stimulated echo DTI were applied to 8 healthy volunteers and 14 suspected CECS patients before and after exertion. Longitudinal and transverse diffusion eigenvalues, mean diffusivity (MD), and fractional anisotropy (FA) were measured in 7 calf muscle compartments, which in patients were classified by their response on T2w: normal (<20% change), and CECS (>20% change). Mixed model analysis of variance compared subject groups and compartments in terms of response factors (post-/pre-exercise ratios) of DTI parameters. Results All diffusivities significantly increased (p<0.0001) and FA decreased (p=.0014) with exercise. Longitudinal diffusion responses were significantly smaller than transversal diffusion responses (p<0.0001). 19 of 98 patient compartments were classified as CECS on T2w. MD increased by 3.8±3.4% (volunteer), 7.4±4.2 % (normal), and 9.1±7.0% (CECS) with exercise. Conclusion DTI shows promise as an ancillary imaging method in the diagnosis and understanding of the pathophysiology in CECS. Future studies may explore its utility in predicting response to treatment. PMID:23440764

  19. Radiofrequency power deposition near metallic wires during MR imaging: feasibility study using T1-weighted thermal imaging.

    PubMed

    Oulmane, F; Detti, V; Grenier, D; Perrin, E; Saint-Jalmes, H

    2007-01-01

    The presence of metallic conductors (implants, wires or catheters) is prohibited in MR imaging for safety purpose with respect to radiofrequency (RF) power deposition caused by RF excitation B1 field. This work describes the use of T1-weigthed MR imaging for estimating a thermal map around a metallic (copper) wire located in the center of a MR imaging unit during an imaging sequence. The experimental set up and the methodology used for capturing the elevation of temperature created by radiofrequency power deposition around the wire is presented. A proof of its efficiency to followup temperature elevation about 0,5 degrees C in a milimetric region of interest (pixel size: 1 x 1 mm2, slice thickness 5 mm) located around the wire is given, leading to further developments of MR imaging in presence of metallic implants, coils or catheters.

  20. SU-E-P-33: Critical Role of T2-Weighted Imaging Combined with Diffusion-Weighted Imaging of MRI in Diagnosis of Loco-Regional Recurrent Esophageal Cancer After Radical Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, G; Qiao, L; Liang, N

    Purpose: We perform this study to investigate the diagnostic efficacy of T2-weighted MRI (T2WI) and diffusion-weighted MRI (DWI) in confirming local relapses of esophageal cancer in patients highly suspected of recurrence after eradicating surgery. Methods: Forty-two postoperative esophageal cancer patients with clinical suspicions of cancer recurrence underwent 3.0T MRI applying axial, coronal, sagittal T2WI and axial DWI sequences. Two experienced radiologists (R1 and R2) both used two methods (T2WI, T2WI+DWI) to observe the images, and graded the patients ranging from 1 to 5 to represent severity of the disease based on visual signal intensity (patients equal to or more thanmore » grade 3 was confirmed as recurrent disease) Results: 27/42patients were verified of recurrent disease by pathologic findings and/or imaging findings during follow-up. The sensitivity, specificity and accuracy of R1 applying T2WI+DWI are 96%, 87% and 93% versus 81%, 80% and 77% on T2WI, these figures by R2 were 96%, 93% and 95% versus 89%, 93% and 90%. The receiver operating curve (ROC) analyses suggest that both of the two readers can obtain better accuracy when adding DWI to T2WI compared with T2WI alone. Kappa test between R1 and R2 indicates excellent inter-observer agreement on T2WI+DWI. Conclusion: Standard T2WI in combination DWI can achieve better accuracy than T2WI alone in diagnosing local recurrence of esophageal cancer, and improve consistency between different readers.« less

  1. Coagulative interstitial laser-induced thermotherapy of benign prostatic hyperplasia: online imaging with a T2-weighted fast spin-echo MR sequence--experience in six patients.

    PubMed

    Mueller-Lisse, U G; Thoma, M; Faber, S; Heuck, A F; Muschter, R; Schneede, P; Weninger, E; Hofstetter, A G; Reiser, M F

    1999-02-01

    To determine if hypointense lesions clearly outline on T2-weighted fast spin-echo (SE) magnetic resonance (MR) images obtained during coagulative interstitial laser-induced thermotherapy (LITT) of a prostate with benign hyperplasia. In six patients with benign prostatic hyperplasia (BPH), 12 LITT treatments were followed online with repetitive axial T2-weighted fast SE imaging (repetition time, 3,700 msec; echo time, 138 msec; acquisition time, 19 seconds). Development, time course, correlation with interstitial tissue temperature, and diameters of hypointense lesions around the laser diffusor tip were investigated. Lesion diameters on T2-weighted images acquired during LITT were compared with diameters of final lesions on T2-weighted images and unperfused lesions on enhanced T1-weighted SE images obtained at the end of therapy. Hypointense lesions developed within 20-40 seconds of LITT. Average correlation coefficients between interstitial temperature development and signal intensity development were 0.92 during LITT and 0.90 after LITT. Regression slopes were significantly steeper during LITT (0.67% signal intensity change per degree Celsius) than after LITT (0.47% per degree Celsius; P = .038). Lesions remained visible after LITT for all procedures. Average maximum diameters of lesions were 1-3 mm larger during LITT than after LITT (P = .0006-.019). Repetitive T2-weighted fast SE MR imaging during interstitial coagulative LITT of BPH demonstrates the development of permanent hypointense prostate lesions. However, posttherapeutic lesion diameters tend to be overestimated during LITT.

  2. Detailed T1-Weighted Profiles from the Human Cortex Measured in Vivo at 3 Tesla MRI.

    PubMed

    Ferguson, Bart; Petridou, Natalia; Fracasso, Alessio; van den Heuvel, Martijn P; Brouwer, Rachel M; Hulshoff Pol, Hilleke E; Kahn, René S; Mandl, René C W

    2018-04-01

    Studies into cortical thickness in psychiatric diseases based on T1-weighted MRI frequently report on aberrations in the cerebral cortex. Due to limitations in image resolution for studies conducted at conventional MRI field strengths (e.g. 3 Tesla (T)) this information cannot be used to establish which of the cortical layers may be implicated. Here we propose a new analysis method that computes one high-resolution average cortical profile per brain region extracting myeloarchitectural information from T1-weighted MRI scans that are routinely acquired at a conventional field strength. To assess this new method, we acquired standard T1-weighted scans at 3 T and compared them with state-of-the-art ultra-high resolution T1-weighted scans optimised for intracortical myelin contrast acquired at 7 T. Average cortical profiles were computed for seven different brain regions. Besides a qualitative comparison between the 3 T scans, 7 T scans, and results from literature, we tested if the results from dynamic time warping-based clustering are similar for the cortical profiles computed from 7 T and 3 T data. In addition, we quantitatively compared cortical profiles computed for V1, V2 and V7 for both 7 T and 3 T data using a priori information on their relative myelin concentration. Although qualitative comparisons show that at an individual level average profiles computed for 7 T have more pronounced features than 3 T profiles the results from the quantitative analyses suggest that average cortical profiles computed from T1-weighted scans acquired at 3 T indeed contain myeloarchitectural information similar to profiles computed from the scans acquired at 7 T. The proposed method therefore provides a step forward to study cortical myeloarchitecture in vivo at conventional magnetic field strength both in health and disease.

  3. T2-weighted four dimensional magnetic resonance imaging with result-driven phase sorting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Yilin; Yin, Fang-Fang; Cai, Jing, E-mail: jing.cai@duke.edu

    2015-08-15

    involved in an IRB-approved study to investigate the feasibility of this technique. Results: 4D data acquisition completeness (C{sub p}) increases as NR increases in an inverse-exponential fashion (C{sub p} = 100 − 99 × exp(−0.18 × N{sub R}), when N{sub B} = 6, fitted using 29 patients’ data). The N{sub R} required for 4D-MRI reconstruction (defined as achieving 95% completeness, C{sub p} = 95%, N{sub R} = N{sub R,95}) is proportional to N{sub B} (N{sub R,95} ∼ 2.86 × N{sub B}, r = 1.0), but independent of N{sub S} and P{sub 0}. Simulated XCAT 4D-MRI showed a clear pattern of respiratory motion. Tumor motion trajectories measured on 4D-MRI were comparable to the average input signal, with a mean relative amplitude error of 2.7% ± 2.9%. Reconstructed 4D-MRI for healthy volunteers illustrated clear respiratory motion on three orthogonal planes, with minimal image artifacts. The artifacts were presumably caused by breathing irregularity and incompleteness of data acquisition (95% acquired only). The mean relative amplitude error between critical structure trajectory and average breathing curve for 12 healthy volunteers is 2.5 ± 0.3 mm in superior–inferior direction. Conclusions: A novel T2-weighted retrospective phase sorting 4D-MRI technique has been developed and successfully applied on digital phantom and healthy volunteers.« less

  4. High-resolution T2-weighted abdominal magnetic resonance imaging using respiratory triggering: impact of butylscopolamine on image quality.

    PubMed

    Wagner, M; Klessen, C; Rief, M; Elgeti, T; Taupitz, M; Hamm, B; Asbach, P

    2008-05-01

    Respiratory triggering allows the acquisition of high-resolution magnetic resonance (MR) images of the upper abdomen. However, the depiction of organs close to the gastrointestinal tract can be considerably impaired by ghosting artifacts and blurring caused by bowel peristalsis. To evaluate the effect of gastrointestinal motion suppression by intramuscular butylscopolamine administration on the image quality of a respiratory-triggered T2-weighted turbo spin-echo (T2w TSE) sequence of the upper abdomen. Images of 46 patients were retrospectively analyzed. Twenty-four patients had received intramuscular injection of 40 mg butylscopolamine immediately before MR imaging. Fourteen of the 24 patients in the butylscopolamine group underwent repeat imaging after a mean of 29 min. Quantitative analysis of the ghosting artifacts was done by measuring signal intensities in regions of interest placed in air anterior to the patient. In addition, image quality was assessed qualitatively by two radiologists by consensus. Spasmolytic medication with butylscopolamine reduced ghosting artifacts and significantly improved image quality of the respiratory-triggered T2w TSE sequence. The most pronounced effect of butylscopolamine administration on image quality was found for the pancreas and the left hepatic lobe. The rate of examinations with excellent or good depiction of the pancreas and the left hepatic lobe in the group without premedication and in the butylscopolamine group was 55% vs. 96% (pancreatic head), 35% vs. 88% (pancreatic body), 43% vs. 96% (pancreatic tail), and 45% vs. 83% (left hepatic lobe), respectively. Regarding the duration of the effect of intramuscular butylscopolamine, repeat imaging after a mean of 29 min did not result in a significant deterioration of image quality. Intramuscular butylscopolamine administration significantly improves image quality of respiratory-triggered T2-weighted abdominal MR imaging by persistent reduction of peristaltic artifacts. MR

  5. Diffusion-Weighted Magnetic Resonance Imaging of Cholesteatoma Using PROPELLER at 1.5T: A Single-Centre Retrospective Study.

    PubMed

    Clarke, Sharon E; Mistry, Dipan; AlThubaiti, Talal; Khan, M Naeem; Morris, David; Bance, Manohar

    2017-05-01

    The purpose of this study was to evaluate the sensitivity, specificity, and positive and negative predictive values of the diffusion-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique in the detection of cholesteatoma at our institution with surgical confirmation in all cases. A retrospective review of 21 consecutive patients who underwent diffusion-weighted PROPELLER magnetic resonance imaging (MRI) on a 1.5T MRI scanner prior to primary or revision/second-look surgery for suspected cholesteatoma from 2009-2012 was performed. Diffusion-weighted PROPELLER had a sensitivity of 75%, specificity of 60%, positive predictive value of 86%, and negative predictive value of 43%. In the 15 patients for whom the presence or absence of cholesteatoma was correctly predicted, there were 2 cases where the reported locations of diffusion restriction did not correspond to the location of the cholesteatoma observed at surgery. On the basis of our retrospective study, we conclude that diffusion-weighted PROPELLER MRI is not sufficiently accurate to replace second look surgery at our institution. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Evaluation of the Subscapularis Tendon Tears on 3T Magnetic Resonance Arthrography: Comparison of Diagnostic Performance of T1-Weighted Spectral Presaturation with Inversion-Recovery and T2-Weighted Turbo Spin-Echo Sequences.

    PubMed

    Lee, Hoseok; Ahn, Joong Mo; Kang, Yusuhn; Oh, Joo Han; Lee, Eugene; Lee, Joon Woo; Kang, Heung Sik

    2018-01-01

    To compare the T1-weighted spectral presaturation with inversion-recovery sequences (T1 SPIR) with T2-weighted turbo spin-echo sequences (T2 TSE) on 3T magnetic resonance arthrography (MRA) in the evaluation of the subscapularis (SSC) tendon tear with arthroscopic findings as the reference standard. This retrospective study included 120 consecutive patients who had undergone MRA within 3 months between April and December 2015. Two musculoskeletal radiologists blinded to the arthroscopic results evaluated T1 SPIR and T2 TSE images in separate sessions for the integrity of the SSC tendon, examining normal/articular-surface partial-thickness tear (PTTa)/full-thickness tear (FTT). Diagnostic performance of T1 SPIR and T2 TSE was calculated with arthroscopic results as the reference standard, and sensitivity, specificity, and accuracy were compared using the McNemar test. Interobserver agreement was measured with kappa (κ) statistics. There were 74 SSC tendon tears (36 PTTa and 38 FTT) confirmed by arthroscopy. Significant differences were found in the sensitivity and accuracy between T1 SPIR and T2 TSE using the McNemar test, with respective rates of 95.9-94.6% vs. 71.6-75.7% and 90.8-91.7% vs. 79.2-83.3% for detecting tear; 55.3% vs. 31.6-34.2% and 85.8% vs. 78.3-79.2%, respectively, for FTT; and 91.7-97.2% vs. 58.3-61.1% and 89% vs. 78-79.3%, respectively, for PTTa. Interobserver agreement for T1 SPIR was almost perfect for T1 SPIR (κ = 0.839) and substantial for T2 TSE (κ = 0.769). T1-weighted spectral presaturation with inversion-recovery sequences is more sensitive and accurate compared to T2 TSE in detecting SSC tendon tear on 3T MRA.

  7. Biocompatible and high-performance amino acids-capped MnWO4 nanocasting as a novel non-lanthanide contrast agent for X-ray computed tomography and T1-weighted magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Dong, Kai; Liu, Zhen; Liu, Jianhua; Huang, Sa; Li, Zhenhua; Yuan, Qinghai; Ren, Jinsong; Qu, Xiaogang

    2014-01-01

    In the present work, a novel non-lanthanide dual-modality contrast agent, manganese tungstate (MnWO4), has been successfully constructed by a facile and versatile hydrothermal route. With the merits of a high atomic number and a well-positioned K-edge energy of tungsten, our well-prepared non-lanthanide nanoprobes provide a higher contrast efficacy than routine iodine-based agents in clinics. Additionally, the presence of Mn in these nanoparticles endow them with excellent T1-weighted MR imaging capabilities. As an alternative to T2-weighted MRI and CT dual-modality contrast agents, the nanoprobes can provide a positive contrast signal, which prevents confusion with the dark signals from hemorrhage and blood clots. To the best of our knowledge, this is the first report that a non-lanthanide imaging nanoprobe is applied for CT and T1-weighted MRI simultaneously. Moreover, comparing with gadolinium-based T1-weighted MRI and CT dual-modality contrast agents that were associated with nephrogenic systemic fibrosis (NSF), our contrast agents have superior biocompatibility, which is proved by a detailed study of the pharmacokinetics, biodistribution, and in vivo toxicology. Together with excellent dispersibility, high biocompatibility and superior contrast efficacy, these nanoprobes provide detailed and complementary information from dual-modality imaging over traditional single-mode imaging and bring more opportunities to the new generation of non-lanthanide nanoparticulate-based contrast agents.In the present work, a novel non-lanthanide dual-modality contrast agent, manganese tungstate (MnWO4), has been successfully constructed by a facile and versatile hydrothermal route. With the merits of a high atomic number and a well-positioned K-edge energy of tungsten, our well-prepared non-lanthanide nanoprobes provide a higher contrast efficacy than routine iodine-based agents in clinics. Additionally, the presence of Mn in these nanoparticles endow them with excellent T1

  8. Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T.

    PubMed

    Morelli, John; Porter, David; Ai, Fei; Gerdes, Clint; Saettele, Megan; Feiweier, Thorsten; Padua, Abraham; Dix, James; Marra, Michael; Rangaswamy, Rajesh; Runge, Val

    2013-04-01

    Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. SNR and CNR were greatest with rs-EPI (8.1 ± 0.2 SNR vs. 6.0 ± 0.2; P <10(-4) at 3T). Spatial distortions were greater with single-shot (0.23 ± 0.03 at 3T; P <0.001) than with rs-EPI (0.12 ± 0.02 at 3T). Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain.

  9. Reference-tissue correction of T2-weighted signal intensity for prostate cancer detection

    NASA Astrophysics Data System (ADS)

    Peng, Yahui; Jiang, Yulei; Oto, Aytekin

    2014-03-01

    The purpose of this study was to investigate whether correction with respect to reference tissue of T2-weighted MRimage signal intensity (SI) improves its effectiveness for classification of regions of interest (ROIs) as prostate cancer (PCa) or normal prostatic tissue. Two image datasets collected retrospectively were used in this study: 71 cases acquired with GE scanners (dataset A), and 59 cases acquired with Philips scanners (dataset B). Through a consensus histology- MR correlation review, 175 PCa and 108 normal-tissue ROIs were identified and drawn manually. Reference-tissue ROIs were selected in each case from the levator ani muscle, urinary bladder, and pubic bone. T2-weighted image SI was corrected as the ratio of the average T2-weighted image SI within an ROI to that of a reference-tissue ROI. Area under the receiver operating characteristic curve (AUC) was used to evaluate the effectiveness of T2-weighted image SIs for differentiation of PCa from normal-tissue ROIs. AUC (+/- standard error) for uncorrected T2-weighted image SIs was 0.78+/-0.04 (datasets A) and 0.65+/-0.05 (datasets B). AUC for corrected T2-weighted image SIs with respect to muscle, bladder, and bone reference was 0.77+/-0.04 (p=1.0), 0.77+/-0.04 (p=1.0), and 0.75+/-0.04 (p=0.8), respectively, for dataset A; and 0.81+/-0.04 (p=0.002), 0.78+/-0.04 (p<0.001), and 0.79+/-0.04 (p<0.001), respectively, for dataset B. Correction in reference to the levator ani muscle yielded the most consistent results between GE and Phillips images. Correction of T2-weighted image SI in reference to three types of extra-prostatic tissue can improve its effectiveness for differentiation of PCa from normal-tissue ROIs, and correction in reference to the levator ani muscle produces consistent T2-weighted image SIs between GE and Phillips MR images.

  10. 3D Fast Spin Echo T2-weighted Contrast for Imaging the Female Cervix

    NASA Astrophysics Data System (ADS)

    Vargas Sanchez, Andrea Fernanda

    Magnetic Resonance Imaging (MRI) with T2-weighted contrast is the preferred modality for treatment planning and monitoring of cervical cancer. Current clinical protocols image the volume of interest multiple times with two dimensional (2D) T2-weighted MRI techniques. It is of interest to replace these multiple 2D acquisitions with a single three dimensional (3D) MRI acquisition to save time. However, at present the image contrast of standard 3D MRI does not distinguish cervical healthy tissue from cancerous tissue. The purpose of this thesis is to better understand the underlying factors that govern the contrast of 3D MRI and exploit this understanding via sequence modifications to improve the contrast. Numerical simulations are developed to predict observed contrast alterations and to propose an improvement. Improvements of image contrast are shown in simulation and with healthy volunteers. Reported results are only preliminary but a promising start to establish definitively 3D MRI for cervical cancer applications.

  11. High-resolution T1-weighted 3D real IR imaging of the temporal bone using triple-dose contrast material.

    PubMed

    Naganawa, Shinji; Koshikawa, Tokiko; Nakamura, Tatsuya; Fukatsu, Hiroshi; Ishigaki, Takeo; Aoki, Ikuo

    2003-12-01

    The small structures in the temporal bone are surrounded by bone and air. The objectives of this study were (a) to compare contrast-enhanced T1-weighted images acquired by fast spin-echo-based three-dimensional real inversion recovery (3D rIR) against those acquired by gradient echo-based 3D SPGR in the visualization of the enhancement of small structures in the temporal bone, and (b) to determine whether either 3D rIR or 3D SPGR is useful for visualizing enhancement of the cochlear lymph fluid. Seven healthy men (age range 27-46 years) volunteered to participate in this study. All MR imaging was performed using a dedicated bilateral quadrature surface phased-array coil for temporal bone imaging at 1.5 T (Visart EX, Toshiba, Tokyo, Japan). The 3D rIR images (TR/TE/TI: 1800 ms/10 ms/500 ms) and flow-compensated 3D SPGR images (TR/TE/FA: 23 ms/10 ms/25 degrees) were obtained with a reconstructed voxel size of 0.6 x 0.7 x 0.8 mm3. Images were acquired before and 1, 90, 180, and 270 min after the administration of triple-dose Gd-DTPA-BMA (0.3 mmol/kg). In post-contrast MR images, the degree of enhancement of the cochlear aqueduct, endolymphatic sac, subarcuate artery, geniculate ganglion of the facial nerve, and cochlear lymph fluid space was assessed by two radiologists. The degree of enhancement was scored as follows: 0 (no enhancement); 1 (slight enhancement); 2 (intermediate between 1 and 3); and 3 (enhancement similar to that of vessels). Enhancement scores for the endolymphatic sac, subarcuate artery, and geniculate ganglion were higher in 3D rIR than in 3D SPGR. Washout of enhancement in the endolymphatic sac appeared to be delayed compared with that in the subarcuate artery, suggesting that the enhancement in the endolymphatic sac may have been due in part to non-vascular tissue enhancement. Enhancement of the cochlear lymph space was not observed in any of the subjects in 3D rIR and 3D SPGR. The 3D rIR sequence may be more sensitive than the 3D SPGR sequence

  12. Artifact Suppression in Imaging of Myocardial Infarction Using B1-Weighted Phased-Array Combined Phase-Sensitive Inversion Recovery

    PubMed Central

    Kellman, Peter; Dyke, Christopher K.; Aletras, Anthony H.; McVeigh, Elliot R.; Arai, Andrew E.

    2007-01-01

    Regions of the body with long T1, such as cerebrospinal fluid (CSF), may create ghost artifacts on gadolinium-hyperenhanced images of myocardial infarction when inversion recovery (IR) sequences are used with a segmented acquisition. Oscillations in the transient approach to steady state for regions with long T1 may cause ghosts, with the number of ghosts being equal to the number of segments. B1-weighted phased-array combining provides an inherent degree of ghost artifact suppression because the ghost artifact is weighted less than the desired signal intensity by the coil sensitivity profiles. Example images are shown that illustrate the suppression of CSF ghost artifacts by the use of B1-weighted phased-array combining of multiple receiver coils. PMID:14755669

  13. Acute pancreatitis with gradient echo T2*-weighted magnetic resonance imaging

    PubMed Central

    Tang, Meng Yue; Chen, Tian Wu; Huang, Xiao Hua; Li, Xing Hui; Wang, Si Yue; Liu, Nian

    2016-01-01

    Background To study gradient recalled echo (GRE) T2*-weighted imaging (T2*WI) for normal pancreas and acute pancreatitis (AP). Methods Fifty-one patients without any pancreatic disorders (control group) and 117 patients with AP were recruited. T2* values derived from T2*WI of the pancreas were measured for the two groups. The severity of AP was graded by the magnetic resonance severity index (MRSI) and the Acute Physiology and Chronic Healthy Evaluation II (APACHE II) scoring system. Logistic regression was used to analyze the relationship between the T2* values and AP severity. The usefulness of the T2* value for diagnosing AP and the relationship between the T2* values and the severity of AP were analyzed. Results On GRE-T2*WI, the normal pancreas showed a well-marinated and consistently homogeneous isointensity. Edematous AP, as well as the non-necrotic area in necrotizing AP, showed ill-defined but homogeneous signal intensity. AP with pancreatic hemorrhage showed a decreased T2* value and a signal loss on the signal decay curve. The T2* value of pancreas in the AP group was higher than that of the control group (t=−8.20, P<0.05). The T2* value tended to increase along with the increase in MRSI scores but not with the APACHE II scores (P>0.05). AP was associated with a one standard deviation increment in the T2* value (OR =1.37; 95% CI: 1.216–1.532). Conclusions T2*WI demonstrates a few characteristics of the normal pancreas and AP, which could potentially be helpful for detecting hemorrhage, and contributes to diagnosing AP and its severity. PMID:27190768

  14. Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: impact on lesion detection and PI-RADS classification.

    PubMed

    Meier-Schroers, Michael; Marx, Christian; Schmeel, Frederic Carsten; Wolter, Karsten; Gieseke, Jürgen; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Willinek, Winfried; Schild, Hans Heinz; Kukuk, Guido Matthias

    2018-01-01

    To evaluate revised PROPELLER (RevPROP) for T2-weighted imaging (T2WI) of the prostate as a substitute for turbo spin echo (TSE). Three-Tesla MR images of 50 patients with 55 cancer-suspicious lesions were prospectively evaluated. Findings were correlated with histopathology after MRI-guided biopsy. T2 RevPROP, T2 TSE, diffusion-weighted imaging, dynamic contrast enhancement, and MR-spectroscopy were acquired. RevPROP was compared to TSE concerning PI-RADS scores, lesion size, lesion signal-intensity, lesion contrast, artefacts, and image quality. There were 41 carcinomas in 55 cancer-suspicious lesions. RevPROP detected 41 of 41 carcinomas (100%) and 54 of 55 lesions (98.2%). TSE detected 39 of 41 carcinomas (95.1%) and 51 of 55 lesions (92.7%). RevPROP showed fewer artefacts and higher image quality (each p < 0.001). No differences were observed between single and overall PI-RADS scores based on RevPROP or TSE (p = 0.106 and p = 0.107). Lesion size was not different (p = 0.105). T2-signal intensity of lesions was higher and T2-contrast of lesions was lower on RevPROP (each p < 0.001). For prostate cancer detection RevPROP is superior to TSE with respect to motion robustness, image quality and detection rates of lesions. Therefore, RevPROP might be used as a substitute for T2WI. • Revised PROPELLER can be used as a substitute for T2-weighted prostate imaging. • Revised PROPELLER detected more carcinomas and more suspicious lesions than TSE. • Revised PROPELLER showed fewer artefacts and better image quality compared to TSE. • There were no significant differences in PI-RADS scores between revised PROPELLER and TSE. • The lower T2-contrast of revised PROPELLER did not impair its diagnostic quality.

  15. Comparative study of microelectrode recording-based STN location and MRI-based STN location in low to ultra-high field (7.0 T) T2-weighted MRI images

    NASA Astrophysics Data System (ADS)

    Verhagen, Rens; Schuurman, P. Richard; van den Munckhof, Pepijn; Fiorella Contarino, M.; de Bie, Rob M. A.; Bour, Lo J.

    2016-12-01

    Objective. The correspondence between the anatomical STN and the STN observed in T2-weighted MRI images used for deep brain stimulation (DBS) targeting remains unclear. Using a new method, we compared the STN borders seen on MRI images with those estimated by intraoperative microelectrode recordings (MER). Approach. We developed a method to automatically generate a detailed estimation of STN shape and the location of its borders, based on multiple-channel MER measurements. In 33 STNs of 19 Parkinson patients, we quantitatively compared the dorsal and lateral borders of this MER-based STN model with the STN borders visualized by 1.5 T (n = 14), 3.0 T (n = 10) and 7.0 T (n = 9) T2-weighted MRI. Main results. The dorsal border was identified more dorsally on coronal T2 MRI than by the MER-based STN model, with a significant difference in the 3.0 T (range 0.97-1.19 mm) and 7.0 T (range 1.23-1.25 mm) groups. The lateral border was significantly more medial on 1.5 T (mean: 1.97 mm) and 3.0 T (mean: 2.49 mm) MRI than in the MER-based STN; a difference that was not found in the 7.0 T group. Significance. The STN extends further in the dorsal direction on coronal T2 MRI images than is measured by MER. Increasing MRI field strength to 3.0 T or 7.0 T yields similar discrepancies between MER and MRI at the dorsal STN border. In contrast, increasing MRI field strength to 7.0 T may be useful for identification of the lateral STN border and thereby improve DBS targeting.

  16. Composite iron oxide-Prussian blue nanoparticles for magnetically guided T1-weighted magnetic resonance imaging and photothermal therapy of tumors.

    PubMed

    Kale, Shraddha S; Burga, Rachel A; Sweeney, Elizabeth E; Zun, Zungho; Sze, Raymond W; Tuesca, Anthony; Subramony, J Anand; Fernandes, Rohan

    2017-01-01

    Theranostic nanoparticles offer the potential for mixing and matching disparate diagnostic and therapeutic functionalities within a single nanoparticle for the personalized treatment of diseases. In this article, we present composite iron oxide-gadolinium-containing Prussian blue nanoparticles (Fe 3 O 4 @GdPB) as a novel theranostic agent for T 1 -weighted magnetic resonance imaging (MRI) and photothermal therapy (PTT) of tumors. These particles combine the well-described properties and safety profiles of the constituent Fe 3 O 4 nanoparticles and gadolinium-containing Prussian blue nanoparticles. The Fe 3 O 4 @GdPB nanoparticles function both as effective MRI contrast agents and PTT agents as determined by characterizing studies performed in vitro and retain their properties in the presence of cells. Importantly, the Fe 3 O 4 @GdPB nanoparticles function as effective MRI contrast agents in vivo by increasing signal:noise ratios in T 1 -weighted scans of tumors and as effective PTT agents in vivo by decreasing tumor growth rates and increasing survival in an animal model of neuroblastoma. These findings demonstrate the potential of the Fe 3 O 4 @GdPB nanoparticles to function as effective theranostic agents.

  17. Composite iron oxide–Prussian blue nanoparticles for magnetically guided T1-weighted magnetic resonance imaging and photothermal therapy of tumors

    PubMed Central

    Kale, Shraddha S; Burga, Rachel A; Sweeney, Elizabeth E; Zun, Zungho; Sze, Raymond W; Tuesca, Anthony; Subramony, J Anand; Fernandes, Rohan

    2017-01-01

    Theranostic nanoparticles offer the potential for mixing and matching disparate diagnostic and therapeutic functionalities within a single nanoparticle for the personalized treatment of diseases. In this article, we present composite iron oxide-gadolinium-containing Prussian blue nanoparticles (Fe3O4@GdPB) as a novel theranostic agent for T1-weighted magnetic resonance imaging (MRI) and photothermal therapy (PTT) of tumors. These particles combine the well-described properties and safety profiles of the constituent Fe3O4 nanoparticles and gadolinium-containing Prussian blue nanoparticles. The Fe3O4@GdPB nanoparticles function both as effective MRI contrast agents and PTT agents as determined by characterizing studies performed in vitro and retain their properties in the presence of cells. Importantly, the Fe3O4@GdPB nanoparticles function as effective MRI contrast agents in vivo by increasing signal:noise ratios in T1-weighted scans of tumors and as effective PTT agents in vivo by decreasing tumor growth rates and increasing survival in an animal model of neuroblastoma. These findings demonstrate the potential of the Fe3O4@GdPB nanoparticles to function as effective theranostic agents. PMID:28919744

  18. Acoustic-noise-optimized diffusion-weighted imaging.

    PubMed

    Ott, Martin; Blaimer, Martin; Grodzki, David M; Breuer, Felix A; Roesch, Julie; Dörfler, Arnd; Heismann, Björn; Jakob, Peter M

    2015-12-01

    This work was aimed at reducing acoustic noise in diffusion-weighted MR imaging (DWI) that might reach acoustic noise levels of over 100 dB(A) in clinical practice. A diffusion-weighted readout-segmented echo-planar imaging (EPI) sequence was optimized for acoustic noise by utilizing small readout segment widths to obtain low gradient slew rates and amplitudes instead of faster k-space coverage. In addition, all other gradients were optimized for low slew rates. Volunteer and patient imaging experiments were conducted to demonstrate the feasibility of the method. Acoustic noise measurements were performed and analyzed for four different DWI measurement protocols at 1.5T and 3T. An acoustic noise reduction of up to 20 dB(A) was achieved, which corresponds to a fourfold reduction in acoustic perception. The image quality was preserved at the level of a standard single-shot (ss)-EPI sequence, with a 27-54% increase in scan time. The diffusion-weighted imaging technique proposed in this study allowed a substantial reduction in the level of acoustic noise compared to standard single-shot diffusion-weighted EPI. This is expected to afford considerably more patient comfort, but a larger study would be necessary to fully characterize the subjective changes in patient experience.

  19. Au Nanocage Functionalized with Ultra-small Fe3O4 Nanoparticles for Targeting T1-T2Dual MRI and CT Imaging of Tumor

    NASA Astrophysics Data System (ADS)

    Wang, Guannan; Gao, Wei; Zhang, Xuanjun; Mei, Xifan

    2016-06-01

    Diagnostic approaches based on multimodal imaging of clinical noninvasive imaging (eg. MRI/CT scanner) are highly developed in recent years for accurate selection of the therapeutic regimens in critical diseases. Therefore, it is highly demanded in the development of appropriate all-in-one multimodal contrast agents (MCAs) for the MRI/CT multimodal imaging. Here a novel ideal MCAs (F-AuNC@Fe3O4) were engineered by assemble Au nanocages (Au NC) and ultra-small iron oxide nanoparticles (Fe3O4) for simultaneous T1-T2dual MRI and CT contrast imaging. In this system, the Au nanocages offer facile thiol modification and strong X-ray attenuation property for CT imaging. The ultra-small Fe3O4 nanoparticles, as excellent contrast agent, is able to provide great enhanced signal of T1- and T2-weighted MRI (r1 = 6.263 mM-1 s-1, r2 = 28.117 mM-1 s-1) due to their ultra-refined size. After functionalization, the present MCAs nanoparticles exhibited small average size, low aggregation and excellent biocompatible. In vitro and In vivo studies revealed that the MCAs show long-term circulation time, renal clearance properties and outstanding capability of selective accumulation in tumor tissues for simultaneous CT imaging and T1- and T2-weighted MRI. Taken together, these results show that as-prepared MCAs are excellent candidates as MRI/CT multimodal imaging contrast agents.

  20. Tumor segmentation of multi-echo MR T2-weighted images with morphological operators

    NASA Astrophysics Data System (ADS)

    Torres, W.; Martín-Landrove, M.; Paluszny, M.; Figueroa, G.; Padilla, G.

    2009-02-01

    In the present work an automatic brain tumor segmentation procedure based on mathematical morphology is proposed. The approach considers sequences of eight multi-echo MR T2-weighted images. The relaxation time T2 characterizes the relaxation of water protons in the brain tissue: white matter, gray matter, cerebrospinal fluid (CSF) or pathological tissue. Image data is initially regularized by the application of a log-convex filter in order to adjust its geometrical properties to those of noiseless data, which exhibits monotonously decreasing convex behavior. Finally the regularized data is analyzed by means of an 8-dimensional morphological eccentricity filter. In a first stage, the filter was used for the spatial homogenization of the tissues in the image, replacing each pixel by the most representative pixel within its structuring element, i.e. the one which exhibits the minimum total distance to all members in the structuring element. On the filtered images, the relaxation time T2 is estimated by means of least square regression algorithm and the histogram of T2 is determined. The T2 histogram was partitioned using the watershed morphological operator; relaxation time classes were established and used for tissue classification and segmentation of the image. The method was validated on 15 sets of MRI data with excellent results.

  1. Development of PEGylated KMnF3 nanoparticles as a T1-weighted contrast agent: chemical synthesis, in vivo brain MR imaging, and accounting for high relaxivity.

    PubMed

    Liu, Zhi-jun; Song, Xiao-xia; Tang, Qun

    2013-06-07

    Magnetic nanoparticles consisting of manganese-based T1-weighted contrast agents have rapidly achieved clinical application, however low proton relaxivity impedes further development. In this report, by analyzing nanoparticles' surface oxidation states we propose the possible reason for the low r1 relaxivity of common MnO nanoparticles and develop PEGylated fluoroperovskite KMnF3 nanoparticles as new T1-weighted contrast agents, which exhibit the highest longitudinal relaxivity (r1 = 23.15 mM(-1) s(-1)) among all the reported manganese-based T1-weighted contrast agents. We, for the first time, illustrate a typical example showing that the surface oxidation states of metal ions exposed on the nanoparticles' surfaces are able to influence not only the optical, magnetic, electronic or catalytic properties but also water proton longitudinal relaxivity when applied as an MRI contrast agent. Cytotoxicity tests demonstrate that the PEGylated KMnF3 nanoparticles are free from toxicity. Further in vivo MRI experiments distinctively depict fine anatomical features in brain imaging at a low dose of 5 mg of Mn per kg and possible removal from the kidneys due to their small size and biocompatibility.

  2. High resolution T2(*)-weighted Magnetic Resonance Imaging at 3 Tesla using PROPELLER-EPI.

    PubMed

    Krämer, Martin; Reichenbach, Jürgen R

    2014-05-01

    We report the application of PROPELLER-EPI for high resolution T2(*)-weighted imaging with sub-millimeter in-plane resolution on a clinical 3 Tesla scanner. Periodically rotated blades of a long-axis PROPELLER-EPI sequence were acquired with fast gradient echo readout and acquisition matrix of 320 × 50 per blade. Images were reconstructed by using 2D-gridding, phase and geometric distortion correction and compensation of resonance frequency drifts that occurred during extended measurements. To characterize these resonance frequency offsets, short FID calibration measurements were added to the PROPELLER-EPI sequence. Functional PROPELLER-EPI was performed with volunteers using a simple block design of right handed finger tapping. Results indicate that PROPELLER-EPI can be employed for fast, high resolution T2(*)-weighted imaging provided geometric distortions and possible resonance frequency drifts are properly corrected. Even small resonance frequency drifts below 10 Hz as well as non-corrected geometric distortions degraded image quality substantially. In the initial fMRI experiment image quality and signal-to-noise ratio was sufficient for obtaining high resolution functional activation maps. Copyright © 2014. Published by Elsevier GmbH.

  3. Hepatic lesions: improved image quality and detection with the periodically rotated overlapping parallel lines with enhanced reconstruction technique--evaluation of SPIO-enhanced T2-weighted MR images.

    PubMed

    Hirokawa, Yuusuke; Isoda, Hiroyoshi; Maetani, Yoji S; Arizono, Shigeki; Shimada, Kotaro; Okada, Tomohisa; Shibata, Toshiya; Togashi, Kaori

    2009-05-01

    To evaluate the effectiveness of the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique for superparamagnetic iron oxide (SPIO)-enhanced T2-weighted magnetic resonance (MR) imaging with respiratory compensation with the prospective acquisition correction (PACE) technique in the detection of hepatic lesions. The institutional human research committee approved this prospective study, and all patients provided written informed consent. Eighty-one patients (mean age, 58 years) underwent hepatic 1.5-T MR imaging. Fat-saturated T2-weighted turbo spin-echo images were acquired with the PACE technique and with and without the PROPELLER method after administration of SPIO. Images were qualitatively evaluated for image artifacts, depiction of liver edge and intrahepatic vessels, overall image quality, and presence of lesions. Three radiologists independently assessed these characteristics with a five-point confidence scale. Diagnostic performance was assessed with receiver operating characteristic (ROC) curve analysis. Quantitative analysis was conducted by measuring the liver signal-to-noise ratio (SNR) and the lesion-to-liver contrast-to-noise ratio (CNR). The Wilcoxon signed rank test and two-tailed Student t test were used, and P < .05 indicated a significant difference. MR imaging with the PROPELLER and PACE techniques resulted in significantly improved image quality, higher sensitivity, and greater area under the ROC curve for hepatic lesion detection than did MR imaging with the PACE technique alone (P < .001). The mean liver SNR and the lesion-to-liver CNR were higher with the PROPELLER technique than without it (P < .001). T2-weighted MR imaging with the PROPELLER and PACE technique and SPIO enhancement is a promising method with which to improve the detection of hepatic lesions. (c) RSNA, 2009.

  4. [The use of the T2-weighted turbo-spin-echo sequence in studying the neurocranium. A comparison with the conventional T2-weighted spin-echo sequence].

    PubMed

    Siewert, C; Hosten, N; Felix, R

    1994-07-01

    T2-weighted spin-echo imaging is the standard screening procedure in MR imaging of the neurocranium. We evaluated fast spin-echo T2-weighted imaging (TT2) of the neurocranium in comparison to conventional spin-echo T2-weighted imaging (T2). Signal-to-noise and contrast-to-noise ratio of normal brain tissues (basal ganglia, grey and white matter, CSF fluid) and different pathologies were calculated. Signal-to-noise ratio and contrast-to-noise ratio were significantly higher in TT2 than in T2 (with the exception of gray-to-white matter contrast). Tissues with increased content of water protons (mobile protons) showed the highest contrast to surrounding tissues. The increased signal intensity of fat must be given due attention in fatty lesions. Because the contrast-to-noise ratio between white matter and basal ganglia is less in TT2, Parkinson patients have to be examined by conventional T2. If these limitations are taken into account, fast spin-echo T2-weighted imaging is well appropriate for MR imaging of the neurocranium, resulting in heavy T2-weighting achieved in a short acquisition time.

  5. Comparison of 3T and 7T susceptibility-weighted angiography of the substantia nigra in diagnosing Parkinson disease.

    PubMed

    Cosottini, M; Frosini, D; Pesaresi, I; Donatelli, G; Cecchi, P; Costagli, M; Biagi, L; Ceravolo, R; Bonuccelli, U; Tosetti, M

    2015-03-01

    Standard neuroimaging fails in defining the anatomy of the substantia nigra and has a marginal role in the diagnosis of Parkinson disease. Recently 7T MR target imaging of the substantia nigra has been useful in diagnosing Parkinson disease. We performed a comparative study to evaluate whether susceptibility-weighted angiography can diagnose Parkinson disease with a 3T scanner. Fourteen patients with Parkinson disease and 13 healthy subjects underwent MR imaging examination at 3T and 7T by using susceptibility-weighted angiography. Two expert blinded observers and 1 neuroradiology fellow evaluated the 3T and 7T images of the sample to identify substantia nigra abnormalities indicative of Parkinson disease. Diagnostic accuracy and intra- and interobserver agreement were calculated separately for 3T and 7T acquisitions. Susceptibility-weighted angiography 7T MR imaging can diagnose Parkinson disease with a mean sensitivity of 93%, specificity of 100%, and diagnostic accuracy of 96%. 3T MR imaging diagnosed Parkinson disease with a mean sensitivity of 79%, specificity of 94%, and diagnostic accuracy of 86%. Intraobserver and interobserver agreement was excellent at 7T. At 3T, intraobserver agreement was excellent for experts, and interobserver agreement ranged between good and excellent. The less expert reader obtained a diagnostic accuracy of 89% at 3T. Susceptibility-weighted angiography images obtained at 3T and 7T differentiate controls from patients with Parkinson disease with a higher diagnostic accuracy at 7T. The capability of 3T in diagnosing Parkinson disease might encourage its use in clinical practice. The use of the more accurate 7T should be supported by a dedicated cost-effectiveness study. © 2015 by American Journal of Neuroradiology.

  6. Introduction of High Throughput Magnetic Resonance T2-Weighted Image Texture Analysis for WHO Grade 2 and 3 Gliomas.

    PubMed

    Kinoshita, Manabu; Sakai, Mio; Arita, Hideyuki; Shofuda, Tomoko; Chiba, Yasuyoshi; Kagawa, Naoki; Watanabe, Yoshiyuki; Hashimoto, Naoya; Fujimoto, Yasunori; Yoshimine, Toshiki; Nakanishi, Katsuyuki; Kanemura, Yonehiro

    2016-01-01

    Reports have suggested that tumor textures presented on T2-weighted images correlate with the genetic status of glioma. Therefore, development of an image analyzing framework that is capable of objective and high throughput image texture analysis for large scale image data collection is needed. The current study aimed to address the development of such a framework by introducing two novel parameters for image textures on T2-weighted images, i.e., Shannon entropy and Prewitt filtering. Twenty-two WHO grade 2 and 28 grade 3 glioma patients were collected whose pre-surgical MRI and IDH1 mutation status were available. Heterogeneous lesions showed statistically higher Shannon entropy than homogenous lesions (p = 0.006) and ROC curve analysis proved that Shannon entropy on T2WI was a reliable indicator for discrimination of homogenous and heterogeneous lesions (p = 0.015, AUC = 0.73). Lesions with well-defined borders exhibited statistically higher Edge mean and Edge median values using Prewitt filtering than those with vague lesion borders (p = 0.0003 and p = 0.0005 respectively). ROC curve analysis also proved that both Edge mean and median values were promising indicators for discrimination of lesions with vague and well defined borders and both Edge mean and median values performed in a comparable manner (p = 0.0002, AUC = 0.81 and p < 0.0001, AUC = 0.83, respectively). Finally, IDH1 wild type gliomas showed statistically lower Shannon entropy on T2WI than IDH1 mutated gliomas (p = 0.007) but no difference was observed between IDH1 wild type and mutated gliomas in Edge median values using Prewitt filtering. The current study introduced two image metrics that reflect lesion texture described on T2WI. These two metrics were validated by readings of a neuro-radiologist who was blinded to the results. This observation will facilitate further use of this technique in future large scale image analysis of glioma.

  7. Multiparametric Magnetic Resonance Imaging of the Prostate for Tumour Detection and Local Staging: Imaging in 1.5T and Histopathologic Correlation.

    PubMed

    Loggitsi, Dimitra; Gyftopoulos, Anastasios; Economopoulos, Nikolaos; Apostolaki, Aikaterini; Kalogeropoulos, Theodoros; Thanos, Anastasios; Alexopoulou, Efthimia; Kelekis, Nikolaos L

    2017-11-01

    The study sought to prospectively evaluate which technique among T2-weighted images, dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI), diffusion-weighted (DW) MRI, or a combination of the 2, is best suited for prostate cancer detection and local staging. Twenty-seven consecutive patients with biopsy-proven adenocarcinoma of the prostate underwent MRI on a 1.5T scanner with a surface phased-array coil prior radical prostatectomy. Combined anatomical and functional imaging was performed with the use of T2-weighted sequences, DCE MRI, and DW MRI. We compared the imaging results with whole mount histopathology. For the multiparametric approach, significantly higher sensitivity values, that is, 53% (95% confidence interval [CI]: 41.0-64.1) were obtained as compared with each modality alone or any combination of the 3 modalities (P < .05). The specificity for this multiparametric approach, being 90.3% (95% CI: 86.3-93.3) was not significantly higher (P < .05) as compared with the values of the combination of T2+DCE MRI, DW+DCE MRI, or DCE MRI alone. Among the 3 techniques, DCE had the best performance for tumour detection in both the peripheral and the transition zone. High negative predictive value rates (>86%) were obtained for both tumour detection and local staging. The combination of T2-weighted sequences, DCE MRI, and DW MRI yields higher diagnostic performance for tumour detection and local staging than can any of these techniques alone or even any combination of them. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  8. Diagnosis of complications associated with acute cholecystitis using computed tomography and diffusion-weighted imaging with background body signal suppression/T2 image fusion.

    PubMed

    Tomizawa, Minoru; Shinozaki, Fuminobu; Tanaka, Satomi; Sunaoshi, Takafumi; Kano, Daisuke; Sugiyama, Eriko; Shite, Misaki; Haga, Ryouta; Fukamizu, Yoshiya; Fujita, Toshiyuki; Kagayama, Satoshi; Hasegawa, Rumiko; Shirai, Yoshinori; Motoyoshi, Yasufumi; Sugiyama, Takao; Yamamoto, Shigenori; Ishige, Naoki

    2017-07-01

    In a clinical setting, it is important to diagnose complications of acute cholecystitis accurately. Diffusion-weighted whole body imaging with background body signal suppression/T2-weighted image fusion (DWIBS/T2) provides high signal intensity with a strong contrast against surrounding tissues in anatomical settings. In the present study, patients who were being treated for acute cholecystitis and underwent DWIBS/T2 in the National Hospital Organization Shimoshizu Hospital between December 2012 and August 2015 were enrolled. A total of 10 men and 4 women underwent DWIBS/T2. Records, including DWIBS/T2 and computed tomography (CT) imaging, were retrospectively analyzed for patients with acute cholecystitis. CT images revealed thickened gallbladder walls in patients with acute cholecystitis, and high signal intensity was observed in DWIBS/T2 images for the thickened gallbladder wall. Inflammation of the pericholecystic space and the liver resulted in high intensity signals with DWIBS/T2 imaging, whereas CT imaging revealed a low-density area in the cholecystic space. Plain CT scanning identified a low-density area in the liver, which became more obvious with contrast-enhanced CT. DWIBS/T2 imaging showed the inflammation of the liver and pericholesyctic space as an area of high signal intensity. Detectability of inflammation of the pericholecystic space and the liver was the same for DWIBS/T2 and CT, which suggests that DWIBS/T2 has the same sensitivity as CT scanning for the diagnosis of complicated acute cholecystitis. However, the strong contrast shown by DWIBS/T2 allows for easier evaluation of acute cholecystitis than CT scanning.

  9. Physiological noise in murine solid tumours using T2*-weighted gradient-echo imaging: a marker of tumour acute hypoxia?

    PubMed

    Baudelet, Christine; Ansiaux, Réginald; Jordan, Bénédicte F; Havaux, Xavier; Macq, Benoit; Gallez, Bernard

    2004-08-07

    T2*-weighted gradient-echo magnetic resonance imaging (T2*-weighted GRE MRI) was used to investigate spontaneous fluctuations in tumour vasculature non-invasively. FSa fibrosarcomas, implanted intramuscularly (i.m.) in the legs of mice, were imaged at 4.7 T, over a 30 min or 1 h sampling period. On a voxel-by-voxel basis, time courses of signal intensity were analysed using a power spectrum density (PSD) analysis to isolate voxels for which signal changes did not originate from Gaussian white noise or linear drift. Under baseline conditions, the tumours exhibited spontaneous signal fluctuations showing spatial and temporal heterogeneity over the tumour. Statistically significant fluctuations occurred at frequencies ranging from 1 cycle/3 min to 1 cycle/h. The fluctuations were independent of the scanner instabilities. Two categories of signal fluctuations were reported: (i) true fluctuations (TFV), i.e., sequential signal increase and decrease, and (ii) profound drop in signal intensity with no apparent signal recovery (SDV). No temporal correlation between tumour and contralateral muscle fluctuations was observed. Furthermore, treatments aimed at decreasing perfusion-limited hypoxia, such as carbogen combined with nicotinamide and flunarizine, decreased the incidence of tumour T2*-weighted GRE fluctuations. We also tracked dynamic changes in T2* using multiple GRE imaging. Fluctuations of T2* were observed; however, fluctuation maps using PSD analysis could not be generated reliably. An echo-time dependency of the signal fluctuations was observed, which is typical to physiological noise. Finally, at the end of T2*-weighted GRE MRI acquisition, a dynamic contrast-enhanced MRI was performed to characterize the microenvironment in which tumour signal fluctuations occurred in terms of vessel functionality, vascularity and microvascular permeability. Our data showed that TFV were predominantly located in regions with functional vessels, whereas SDV occurred in regions

  10. Diffusion-weighted magnetic resonance imaging of uterine cervical cancer.

    PubMed

    Liu, Ying; Bai, Renju; Sun, Haoran; Liu, Haidong; Wang, Dehua

    2009-01-01

    To determine the feasibility of diffusion-weighted magnetic resonance (MR) imaging (DWI) of uterine cervical cancer and to investigate whether the apparent diffusion coefficient (ADC) values of cervical cancer differ from those of normal cervix and whether they could indicate the histologic type and the pathologic grade of tumor. Forty-two female patients with histopathologically proven uterine cervical cancer and 15 female patients with uterine leiomyomas underwent preoperative MR examinations using a 1.5-T clinical scanner (GE 1.5T Twin-Speed Infinity with Excite II scanner; GE Healthcare, Waukesha, Wis). Scanning sequences included T2-weighted fast spin-echo imaging, T2-weighted fast spin-echo with fat suppression imaging, T1-weighted spin-echo imaging, and DWI with diffusion factors of 0 and 1000 s/mm2. Parameters evaluated consisted of ADC values of uterine cervical cancer and normal cervix. Histologic specimens were stained with hematoxylin and eosin. The cellular densities of 32 uterine cervical cancers were calculated, which were regarded as the ratio of the total area of tumor cell nuclei divided by the area of sample image. Apparent diffusion coefficient value was statistically different (P = 0.000) between normal and cancerous tissue in the uterine cervix; the former one was (mean [SD], 1.50 [0.16]) x 10(-3) mm2/s, and the latter one was (0.88 [0.15]) x 10(-3) mm2/s. Apparent diffusion coefficient value of squamous carcinoma was statistically lower than that of adenocarcinoma (P = 0.040). The ADC value of uterine cervical cancer correlated negatively with cellular density (r = -0.711, P = 0.000) and the grading of tumor (r = -0.778, P = 0.000). Diffusion-weighted MR imaging has a potential ability to differentiate between normal and cancerous tissue in the uterine cervix, and it can indicate the histologic type of uterine cervical cancer as well. The ADC value of uterine cervical cancer represents tumor cellular density, thus providing a new method for

  11. Perfusion weighted imaging and its application in stroke

    NASA Astrophysics Data System (ADS)

    Li, Enzhong; Tian, Jie; Han, Ying; Wang, Huifang; Li, Xingfeng; Zhu, Fuping

    2003-05-01

    To study the technique and application of perfusion weighted imaging (PWI) in the diagnosis and medical treatment of acute stroke, 25 patients were examined by 1.5 T or 1.0 T MRI scanner. The Data analysis was done with "3D Med System" developed by our Lab to process the data and obtain apparent diffusion coefficient (ADC) map, cerebral blood volume (CBV) map, cerebral blood flow (CBF) map as well as mean transit time (MTT) map. In accute stage of stroke, normal or slightly hypointensity in T1-, hyperintensity in T2- and diffusion-weighted images were seen in the cerebral infarction areas. There were hypointensity in CBV map, CBF map and ADC map; and hyperintensity in MTT map that means this infarct area could be saved. If the hyperintensity area in MTT map was larger than the area in diffusion weighted imaging (DWI), the larger part was called penumbra and could be cured by an appropriate thrombolyitic or other therapy. The CBV, CBF and MTT maps are very important in the diagnosis and medical treatment of acute especially hyperacute stroke. Comparing with DWI, we can easily know the situation of penumbra and the effect of curvative therapy. Besides, we can also make a differential diagnosis with this method.

  12. Mapping Human Cortical Areas in vivo Based on Myelin Content as Revealed by T1- and T2-weighted MRI

    PubMed Central

    Glasser, Matthew F.; Van Essen, David C.

    2011-01-01

    Non-invasively mapping the layout of cortical areas in humans is a continuing challenge for neuroscience. We present a new method of mapping cortical areas based on myelin content as revealed by T1-weighted (T1w) and T2-weighted (T2w) MRI. The method is generalizable across different 3T scanners and pulse sequences. We use the ratio of T1w/T2w image intensities to eliminate the MR-related image intensity bias and enhance the contrast to noise ratio for myelin. Data from each subject was mapped to the cortical surface and aligned across individuals using surface-based registration. The spatial gradient of the group average myelin map provides an observer-independent measure of sharp transitions in myelin content across the surface—i.e. putative cortical areal borders. We found excellent agreement between the gradients of the myelin maps and the gradients of published probabilistic cytoarchitectonically defined cortical areas that were registered to the same surface-based atlas. For other cortical regions, we used published anatomical and functional information to make putative identifications of dozens of cortical areas or candidate areas. In general, primary and early unimodal association cortices are heavily myelinated and higher, multi-modal, association cortices are more lightly myelinated, but there are notable exceptions in the literature that are confirmed by our results. The overall pattern in the myelin maps also has important correlations with the developmental onset of subcortical white matter myelination, evolutionary cortical areal expansion in humans compared to macaques, postnatal cortical expansion in humans, and maps of neuronal density in non-human primates. PMID:21832190

  13. Safety of MR Imaging at 1.5 T in Fetuses: A Retrospective Case-Control Study of Birth Weights and the Effects of Acoustic Noise.

    PubMed

    Strizek, Brigitte; Jani, Jacques C; Mucyo, Eugène; De Keyzer, Frederik; Pauwels, Inge; Ziane, Samir; Mansbach, Anne-Laure; Deltenre, Paul; Cos, Teresa; Cannie, Mieke M

    2015-05-01

    To evaluate the effects of exposure to routine magnetic resonance (MR) imaging at 1.5 T during pregnancy on fetal growth and neonatal hearing function in relation to the dose and timing of in utero exposure in a group of newborns at low risk for congenital hearing impairment or deafness. This retrospective case-control study was approved by the local ethics committee, and written informed consent was waived. Between January 2008 and December 2012, a group of 751 neonates exposed to MR imaging in utero and a group of control subjects comprising 10 042 nonexposed neonates, both groups with no risk factors for hearing impairment at birth, were included. Neonatal hearing screening was performed by means of otoacoustic emission testing and auditory brain stem response according to national guidelines, and the prevalence of hearing impairment in the two groups was compared by using a noninferiority test with Wilson score confidence intervals. The effect of MR exposure on birth weight percentile was examined between the singleton neonates in the exposed group and a randomly chosen subset of 1805 singleton newborns of the nonexposed group by performing an analysis of variance. The rate of hearing impairment or deafness was found to be 0% (0 of 751) in the neonates in the exposed group and was not inferior to that in the nonexposed group (34 of 10 042 [0.34%], P < .05). There was no between-group difference in birth weight percentiles (50.6% for exposed vs 48.4% for nonexposed; P = .22). This study showed no adverse effects of exposure to 1.5-T MR imaging in utero on neonatal hearing function or birth weight percentiles. (©) RSNA, 2015.

  14. Voxel-based automated detection of focal cortical dysplasia lesions using diffusion tensor imaging and T2-weighted MRI data.

    PubMed

    Wang, Yanming; Zhou, Yawen; Wang, Huijuan; Cui, Jin; Nguchu, Benedictor Alexander; Zhang, Xufei; Qiu, Bensheng; Wang, Xiaoxiao; Zhu, Mingwang

    2018-05-21

    The aim of this study was to automatically detect focal cortical dysplasia (FCD) lesions in patients with extratemporal lobe epilepsy by relying on diffusion tensor imaging (DTI) and T2-weighted magnetic resonance imaging (MRI) data. We implemented an automated classifier using voxel-based multimodal features to identify gray and white matter abnormalities of FCD in patient cohorts. In addition to the commonly used T2-weighted image intensity feature, DTI-based features were also utilized. A Gaussian processes for machine learning (GPML) classifier was tested on 12 patients with FCD (8 with histologically confirmed FCD) scanned at 1.5 T and cross-validated using a leave-one-out strategy. Moreover, we compared the multimodal GPML paradigm's performance with that of single modal GPML and classical support vector machine (SVM). Our results demonstrated that the GPML performance on DTI-based features (mean AUC = 0.63) matches with the GPML performance on T2-weighted image intensity feature (mean AUC = 0.64). More promisingly, GPML yielded significantly improved performance (mean AUC = 0.76) when applying DTI-based features to multimodal paradigm. Based on the results, it can also be clearly stated that the proposed GPML strategy performed better and is robust to unbalanced dataset contrary to SVM that performed poorly (AUC = 0.69). Therefore, the GPML paradigm using multimodal MRI data containing DTI modality has promising result towards detection of the FCD lesions and provides an effective direction for future researches. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Test – Retest Reliability and Concurrent Validity of in vivo Myelin Content Indices: Myelin Water Fraction and Calibrated T1w/T2w Image Ratio

    PubMed Central

    Arshad, Muzamil; Stanley, Jeffrey A.; Raz, Naftali

    2016-01-01

    In an age-heterogeneous sample of healthy adults, we examined test-retest reliability (with and without participant re-positioning) of two popular MRI methods of estimating myelin content: modeling the short spin-spin (T2) relaxation component of multi-echo imaging data and computing the ratio of T1-weighted and T2-weighted images (T1w/T2w). Taking the myelin water fraction (MWF) index of myelin content derived from the multi-component T2 relaxation data as a standard, we evaluate the concurrent and differential validity of T1w/T2w ratio images. The results revealed high reliability of MWF and T1w/T2w ratio. However, we found significant correlations of low to moderate magnitude between MWF and the T1w/T2w ratio in only two of six examined regions of the cerebral white matter. Notably, significant correlations of the same or greater magnitude were observed for T1w/T2w ratio and the intermediate T2 relaxation time constant, which is believed to reflect differences in the mobility of water between the intracellular and extracellular compartments. We conclude that although both methods are highly reliable and thus well-suited for longitudinal studies, T1w/T2w ratio has low criterion validity and may be not an optimal index of subcortical myelin content. PMID:28009069

  16. Test-retest reliability and concurrent validity of in vivo myelin content indices: Myelin water fraction and calibrated T1 w/T2 w image ratio.

    PubMed

    Arshad, Muzamil; Stanley, Jeffrey A; Raz, Naftali

    2017-04-01

    In an age-heterogeneous sample of healthy adults, we examined test-retest reliability (with and without participant repositioning) of two popular MRI methods of estimating myelin content: modeling the short spin-spin (T 2 ) relaxation component of multi-echo imaging data and computing the ratio of T 1 -weighted and T 2 -weighted images (T 1 w/T 2 w). Taking the myelin water fraction (MWF) index of myelin content derived from the multi-component T 2 relaxation data as a standard, we evaluate the concurrent and differential validity of T 1 w/T 2 w ratio images. The results revealed high reliability of MWF and T 1 w/T 2 w ratio. However, we found significant correlations of low to moderate magnitude between MWF and the T 1 w/T 2 w ratio in only two of six examined regions of the cerebral white matter. Notably, significant correlations of the same or greater magnitude were observed for T 1 w/T 2 w ratio and the intermediate T 2 relaxation time constant, which is believed to reflect differences in the mobility of water between the intracellular and extracellular compartments. We conclude that although both methods are highly reliable and thus well-suited for longitudinal studies, T 1 w/T 2 w ratio has low criterion validity and may be not an optimal index of subcortical myelin content. Hum Brain Mapp 38:1780-1790, 2017. © 2017 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Texture analysis of ultrahigh field T2*-weighted MR images of the brain: application to Huntington's disease.

    PubMed

    Doan, Nhat Trung; van den Bogaard, Simon J A; Dumas, Eve M; Webb, Andrew G; van Buchem, Mark A; Roos, Raymund A C; van der Grond, Jeroen; Reiber, Johan H C; Milles, Julien

    2014-03-01

    To develop a framework for quantitative detection of between-group textural differences in ultrahigh field T2*-weighted MR images of the brain. MR images were acquired using a three-dimensional (3D) T2*-weighted gradient echo sequence on a 7 Tesla MRI system. The phase images were high-pass filtered to remove phase wraps. Thirteen textural features were computed for both the magnitude and phase images of a region of interest based on 3D Gray-Level Co-occurrence Matrix, and subsequently evaluated to detect between-group differences using a Mann-Whitney U-test. We applied the framework to study textural differences in subcortical structures between premanifest Huntington's disease (HD), manifest HD patients, and controls. In premanifest HD, four phase-based features showed a difference in the caudate nucleus. In manifest HD, 7 magnitude-based features showed a difference in the pallidum, 6 phase-based features in the caudate nucleus, and 10 phase-based features in the putamen. After multiple comparison correction, significant differences were shown in the putamen in manifest HD by two phase-based features (both adjusted P values=0.04). This study provides the first evidence of textural heterogeneity of subcortical structures in HD. Texture analysis of ultrahigh field T2*-weighted MR images can be useful for noninvasive monitoring of neurodegenerative diseases. Copyright © 2013 Wiley Periodicals, Inc.

  18. Disruptive chemical doping in a ferritin-based iron oxide nanoparticle to decrease r2 and enhance detection with T1-weighted MRI.

    PubMed

    Clavijo Jordan, M Veronica; Beeman, Scott C; Baldelomar, Edwin J; Bennett, Kevin M

    2014-01-01

    Inorganic doping was used to create flexible, paramagnetic nanoparticle contrast agents for in vivo molecular magnetic resonance imaging (MRI) with low transverse relaxivity (r2). Most nanoparticle contrast agents formed from superparamagnetic metal oxides are developed with high r2. While sensitive, they can have limited in vivo detection due to a number of constraints with T2 or T2*-weighted imaging. T1-weighted imaging is often preferred for molecular MRI, but most T1-shortening agents are small chelates with low metal payload or are nanoparticles that also shorten T2 and limit the range of concentrations detectable with T1-weighting. Here we used tungsten and iron deposition to form doped iron oxide crystals inside the apoferritin cavity to form a WFe nanoparticle with a disordered crystal and un-coupled atomic magnetic moments. The atomic magnetic moments were thus localized, resulting in a principally paramagnetic nanoparticle. The WFe nanoparticles had no coercivity or saturation magnetization at 5 K and sweeping up to ± 20,000 Oe, while native ferritin had a coercivity of 3000 Oe and saturation at ± 20,000 Oe. This tungsten-iron crystal paramagnetism resulted in an increased WFe particle longitudinal relaxivity (r1) of 4870 mm(-1) s(-1) and a reduced transverse relaxivity (r2) of 9076 mm(-1) s(-1) compared with native ferritin. The accumulation of the particles was detected with T1-weighted MRI in concentrations from 20 to 400 nm in vivo, both injected in the rat brain and targeted to the rat kidney glomerulus. The WFe apoferritin nanoparticles were not cytotoxic up to 700 nm particle concentrations, making them potentially important for targeted molecular MRI. Copyright © 2014 John Wiley & Sons, Ltd.

  19. Characterizing iron deposition in multiple sclerosis lesions using susceptibility weighted imaging

    PubMed Central

    Haacke, E. Mark; Makki, Malek; Ge, Yulin; Maheshwari, Megha; Sehgal, Vivek; Hu, Jiani; Selvan, Madeswaran; Wu, Zhen; Latif, Zahid; Xuan, Yang; Khan, Omar; Garbern, James; Grossman, Robert I.

    2009-01-01

    Purpose To investigate whether the variable forms of putative iron deposition seen with susceptibility weighted imaging (SWI) will lead to a set of multiple sclerosis (MS) lesion characteristics different than that seen in conventional MR imaging. Materials and Methods Twenty-seven clinically definite MS patients underwent brain scans using magnetic resonance imaging including: pre- and post-contrast T1-weighted, T2-weighted, FLAIR, and SWI at 1.5T, 3T and 4T. MS lesions were identified separately in each imaging sequence. Lesions identified in SWI were re-evaluated for their iron content using the SWI filtered phase images. Results There were a variety of new lesion characteristics identified by SWI and these were classified into six types. A total of 75 lesions were seen only with conventional imaging, 143 only with SWI and 204 by both. From the iron quantification measurements, a moderate linear correlation between signal intensity and iron content (phase) was established. Conclusion The amount of iron deposition in the brain may serve as a surrogate biomarker for different MS lesion characteristics. SWI showed many lesions missed by conventional methods and six different lesion characteristics. SWI was particularly effective at recognizing the presence of iron in MS lesions and in the basal ganglia and pulvinar thalamus. PMID:19243035

  20. Intramuscular adipose tissue determined by T1-weighted MRI at 3T primarily reflects extramyocellular lipids.

    PubMed

    Akima, Hiroshi; Hioki, Maya; Yoshiko, Akito; Koike, Teruhiko; Sakakibara, Hisataka; Takahashi, Hideyuki; Oshida, Yoshiharu

    2016-05-01

    The purpose of this study was to assess relationships between intramuscular adipose tissue (IntraMAT) content determined by MRI and intramyocellular lipids (IMCL) and extramyocellular lipids (EMCL) determined by (1)H magnetic resonance spectroscopy ((1)H MRS) or echo intensity determined by B-mode ultrasonography of human skeletal muscles. Thirty young and elderly men and women were included. T1-weighted MRI was taken from the right mid-thigh to measure IntraMAT content of the vastus lateralis (VL) and biceps femoris (BF) using a histogram shape-based thresholding technique. IMCL and EMCL were measured from the VL and BF at the right mid-thigh using (1)H MRS. Ultrasonographic images were taken from the VL and BF of the right mid-thigh to measure echo intensity based on gray-scale level for quantitative analysis. There was a significant correlation between IntraMAT content by MRI and EMCL of the VL and BF (VL, r=0.506, P<0.01; BF, r=0.591, P<0.001) and between echo intensity and EMCL of the VL and BF (VL, r=0.485, P<0.05; BF, r=0.648, P<0.01). IntraMAT content was also significantly correlated with echo intensity of the VL and BF (VL, r=0.404, P<0.05; BF, r=0.493, P<0.01). Our study suggests that IntraMAT content determined by T1-weighted MRI at 3T primarily reflects extramyocellular lipids, not intramyocellular lipids, in human skeletal muscles. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Non-contrast T1-mapping detects acute myocardial edema with high diagnostic accuracy: a comparison to T2-weighted cardiovascular magnetic resonance

    PubMed Central

    2012-01-01

    Background T2w-CMR is used widely to assess myocardial edema. Quantitative T1-mapping is also sensitive to changes in free water content. We hypothesized that T1-mapping would have a higher diagnostic performance in detecting acute edema than dark-blood and bright-blood T2w-CMR. Methods We investigated 21 controls (55 ± 13 years) and 21 patients (61 ± 10 years) with Takotsubo cardiomyopathy or acute regional myocardial edema without infarction. CMR performed within 7 days included cine, T1-mapping using ShMOLLI, dark-blood T2-STIR, bright-blood ACUT2E and LGE imaging. We analyzed wall motion, myocardial T1 values and T2 signal intensity (SI) ratio relative to both skeletal muscle and remote myocardium. Results All patients had acute cardiac symptoms, increased Troponin I (0.15-36.80 ug/L) and acute wall motion abnormalities but no LGE. T1 was increased in patient segments with abnormal and normal wall motion compared to controls (1113 ± 94 ms, 1029 ± 59 ms and 944 ± 17 ms, respectively; p < 0.001). T2 SI ratio using STIR and ACUT2E was also increased in patient segments with abnormal and normal wall motion compared to controls (all p < 0.02). Receiver operator characteristics analysis showed that T1-mapping had a significantly larger area-under-the-curve (AUC = 0.94) compared to T2-weighted methods, whether the reference ROI was skeletal muscle or remote myocardium (AUC = 0.58-0.89; p < 0.03). A T1 value of greater than 990 ms most optimally differentiated segments affected by edema from normal segments at 1.5 T, with a sensitivity and specificity of 92 %. Conclusions Non-contrast T1-mapping using ShMOLLI is a novel method for objectively detecting myocardial edema with a high diagnostic performance. T1-mapping may serve as a complementary technique to T2-weighted imaging for assessing myocardial edema in ischemic and non-ischemic heart disease, such as quantifying area-at-risk and diagnosing

  2. Localization of Coronary High-Intensity Signals on T1-Weighted MR Imaging: Relation to Plaque Morphology and Clinical Severity of Angina Pectoris.

    PubMed

    Matsumoto, Kenji; Ehara, Shoichi; Hasegawa, Takao; Sakaguchi, Mikumo; Otsuka, Kenichiro; Yoshikawa, Junichi; Shimada, Kenei

    2015-10-01

    This study sought to investigate the relationship between localization of high-intensity signals (HISs) on T1-weighted imaging (T1WI) with the noncontrast magnetic resonance technique and plaque morphology detected on optical coherence tomography, and the clinical severity of angina pectoris. Since the introduction of the T1WI noncontrast magnetic resonance technique for plaque imaging, some groups have reported that HISs in the coronary artery on T1WI are associated with a vulnerable morphology and future cardiac events. However, the association between the localization of HISs, such as coronary intrawall or intraluminal, and plaque morphology has not been investigated. One hundred lesions with either stable or unstable angina were included and divided into 3 groups according to the following criteria using T1WI. First, the plaques with the ratio between the signal intensities of coronary plaque and cardiac muscle ≤1.0 were classified as non-HISs (n = 39). Then, HISs with the ratio between the signal intensities of coronary plaque and cardiac muscle >1.0 were classified into 2 types by using cross-sectional T1WI. Those localized within the coronary wall when the lumen was identified were defined as intrawall HISs (n = 37), whereas those occupying the lumen when the lumen was not, or even if only partly, identified, were defined as intraluminal HISs (n = 24). Multivariate analysis revealed that intrawall HISs were associated with macrophage accumulation and the absence of calcification assessed by using optical coherence tomography. In contrast, thrombus and intimal vasculature were independent factors associated with intraluminal HISs. Furthermore, 50% of patients with intraluminal HISs experienced rest angina, such as Braunwald class II or III. This study shows that intrawall and intraluminal HISs on T1WI in patients with angina are related to the different types of vulnerable plaque morphology and the clinical severity. Copyright © 2015 American College of

  3. Adaptive Registration of Varying Contrast-Weighted Images for Improved Tissue Characterization (ARCTIC): Application to T1 Mapping

    PubMed Central

    Roujol, Sébastien; Foppa, Murilo; Weingartner, Sebastian; Manning, Warren J.; Nezafat, Reza

    2014-01-01

    Purpose To propose and evaluate a novel non-rigid image registration approach for improved myocardial T1 mapping. Methods Myocardial motion is estimated as global affine motion refined by a novel local non-rigid motion estimation algorithm. A variational framework is proposed, which simultaneously estimates motion field and intensity variations, and uses an additional regularization term to constrain the deformation field using automatic feature tracking. The method was evaluated in 29 patients by measuring the DICE similarity coefficient (DSC) and the myocardial boundary error (MBE) in short axis and four chamber data. Each image series was visually assessed as “no motion” or “with motion”. Overall T1 map quality and motion artifacts were assessed in the 85 T1 maps acquired in short axis view using a 4-point scale (1-non diagnostic/severe motion artifact, 4-excellent/no motion artifact). Results Increased DSC (0.78±0.14 to 0.87±0.03, p<0.001), reduced MBE (1.29±0.72mm to 0.84±0.20mm, p<0.001), improved overall T1 map quality (2.86±1.04 to 3.49±0.77, p<0.001), and reduced T1 map motion artifacts (2.51±0.84 to 3.61±0.64, p<0.001) were obtained after motion correction of “with motion” data (~56% of data). Conclusion The proposed non-rigid registration approach reduces the respiratory-induced motion that occurs during breath-hold T1 mapping, and significantly improves T1 map quality. PMID:24798588

  4. Potential of fluid-attenuated inversion recovery (FLAIR) in identification of temporomandibular joint effusion compared with T2-weighted images.

    PubMed

    Imoto, Kenichi; Otonari-Yamamoto, Mika; Nishikawa, Keiichi; Sano, Tsukasa; Yamamoto, Aya

    2011-08-01

    The purpose of this study was to determine the potential of fluid-attenuated inversion recovery (FLAIR) sequence images in the identification of joint effusion (JE) compared with T2-weighted images. A total of 31 joints (28 patients) with JE were investigated by magnetic resonance imaging (MRI). Regions of interest were placed over JE, cerebrospinal fluid (CSF), and gray matter (GM) on T2-weighted and FLAIR images and their signal intensities compared. The signal intensity ratios (SIRs) of JE and CSF were calculated with GM as the reference point. The Pearson product-moment correlation coefficient was used for the statistical analysis. The SIR of JE showed a strong correlation between T2-weighted and FLAIR images. However, no correlation was observed for CSF. The average suppression ratio for JE was lower than that for CSF. MRI using FLAIR sequences revealed that JE was not just water content, but a fluid accumulation containing elements such as protein. Further studies are needed, and FLAIR sequences could be useful for the diagnosis of pain and symptoms of the temporomandibular joint (TMJ). Copyright © 2011 Mosby, Inc. All rights reserved.

  5. Texture features on T2-weighted magnetic resonance imaging: new potential biomarkers for prostate cancer aggressiveness

    NASA Astrophysics Data System (ADS)

    Vignati, A.; Mazzetti, S.; Giannini, V.; Russo, F.; Bollito, E.; Porpiglia, F.; Stasi, M.; Regge, D.

    2015-04-01

    To explore contrast (C) and homogeneity (H) gray-level co-occurrence matrix texture features on T2-weighted (T2w) Magnetic Resonance (MR) images and apparent diffusion coefficient (ADC) maps for predicting prostate cancer (PCa) aggressiveness, and to compare them with traditional ADC metrics for differentiating low- from intermediate/high-grade PCas. The local Ethics Committee approved this prospective study of 93 patients (median age, 65 years), who underwent 1.5 T multiparametric endorectal MR imaging before prostatectomy. Clinically significant (volume ≥0.5 ml) peripheral tumours were outlined on histological sections, contoured on T2w and ADC images, and their pathological Gleason Score (pGS) was recorded. C, H, and traditional ADC metrics (mean, median, 10th and 25th percentile) were calculated on the largest lesion slice, and correlated with the pGS through the Spearman correlation coefficient. The area under the receiver operating characteristic curve (AUC) assessed how parameters differentiate pGS = 6 from pGS ≥ 7. The dataset included 49 clinically significant PCas with a balanced distribution of pGS. The Spearman ρ and AUC values on ADC were: -0.489, 0.823 (mean) -0.522, 0.821 (median) -0.569, 0.854 (10th percentile) -0.556, 0.854 (25th percentile) -0.386, 0.871 (C); 0.533, 0.923 (H); while on T2w they were: -0.654, 0.945 (C); 0.645, 0.962 (H). AUC of H on ADC and T2w, and C on T2w were significantly higher than that of the mean ADC (p = 0.05). H and C calculated on T2w images outperform ADC parameters in correlating with pGS and differentiating low- from intermediate/high-risk PCas, supporting the role of T2w MR imaging in assessing PCa biological aggressiveness.

  6. Accounting for the Confound of Meninges in Segmenting Entorhinal and Perirhinal Cortices in T1-Weighted MRI.

    PubMed

    Xie, Long; Wisse, Laura E M; Das, Sandhitsu R; Wang, Hongzhi; Wolk, David A; Manjón, Jose V; Yushkevich, Paul A

    2016-10-01

    Quantification of medial temporal lobe (MTL) cortices, including entorhinal cortex (ERC) and perirhinal cortex (PRC), from in vivo MRI is desirable for studying the human memory system as well as in early diagnosis and monitoring of Alzheimer's disease. However, ERC and PRC are commonly over-segmented in T1-weighted (T1w) MRI because of the adjacent meninges that have similar intensity to gray matter in T1 contrast. This introduces errors in the quantification and could potentially confound imaging studies of ERC/PRC. In this paper, we propose to segment MTL cortices along with the adjacent meninges in T1w MRI using an established multi-atlas segmentation framework together with super-resolution technique. Experimental results comparing the proposed pipeline with existing pipelines support the notion that a large portion of meninges is segmented as gray matter by existing algorithms but not by our algorithm. Cross-validation experiments demonstrate promising segmentation accuracy. Further, agreement between the volume and thickness measures from the proposed pipeline and those from the manual segmentations increase dramatically as a result of accounting for the confound of meninges. Evaluated in the context of group discrimination between patients with amnestic mild cognitive impairment and normal controls, the proposed pipeline generates more biologically plausible results and improves the statistical power in discriminating groups in absolute terms comparing to other techniques using T1w MRI. Although the performance of the proposed pipeline is inferior to that using T2-weighted MRI, which is optimized to image MTL sub-structures, the proposed pipeline could still provide important utilities in analyzing many existing large datasets that only have T1w MRI available.

  7. Automatic identification of the reference system based on the fourth ventricular landmarks in T1-weighted MR images.

    PubMed

    Fu, Yili; Gao, Wenpeng; Chen, Xiaoguang; Zhu, Minwei; Shen, Weigao; Wang, Shuguo

    2010-01-01

    The reference system based on the fourth ventricular landmarks (including the fastigial point and ventricular floor plane) is used in medical image analysis of the brain stem. The objective of this study was to develop a rapid, robust, and accurate method for the automatic identification of this reference system on T1-weighted magnetic resonance images. The fully automated method developed in this study consisted of four stages: preprocessing of the data set, expectation-maximization algorithm-based extraction of the fourth ventricle in the region of interest, a coarse-to-fine strategy for identifying the fastigial point, and localization of the base point. The method was evaluated on 27 Brain Web data sets qualitatively and 18 Internet Brain Segmentation Repository data sets and 30 clinical scans quantitatively. The results of qualitative evaluation indicated that the method was robust to rotation, landmark variation, noise, and inhomogeneity. The results of quantitative evaluation indicated that the method was able to identify the reference system with an accuracy of 0.7 +/- 0.2 mm for the fastigial point and 1.1 +/- 0.3 mm for the base point. It took <6 seconds for the method to identify the related landmarks on a personal computer with an Intel Core 2 6300 processor and 2 GB of random-access memory. The proposed method for the automatic identification of the reference system based on the fourth ventricular landmarks was shown to be rapid, robust, and accurate. The method has potentially utility in image registration and computer-aided surgery.

  8. Diffusion-weighted imaging of the breast: principles and clinical applications.

    PubMed

    Woodhams, Reiko; Ramadan, Saadallah; Stanwell, Peter; Sakamoto, Satoko; Hata, Hirofumi; Ozaki, Masanori; Kan, Shinichi; Inoue, Yusuke

    2011-01-01

    Diffusion-weighted imaging provides a novel contrast mechanism in magnetic resonance (MR) imaging and has a high sensitivity in the detection of changes in the local biologic environment. A significant advantage of diffusion-weighted MR imaging over conventional contrast material-enhanced MR imaging is its high sensitivity to change in the microscopic cellular environment without the need for intravenous contrast material injection. Approaches to the assessment of diffusion-weighted breast imaging findings include assessment of these data alone and interpretation of the data in conjunction with T2-weighted imaging findings. In addition, the analysis of apparent diffusion coefficient (ADC) value can be undertaken either in isolation or in combination with diffusion-weighted and T2-weighted imaging. Most previous studies have evaluated ADC value alone; however, overlap in the ADC values of malignant and benign disease has been observed. This overlap may be partly due to selection of b value, which can influence the concomitant effect of perfusion and emphasize the contribution of multicomponent model influences. The simultaneous assessment of diffusion-weighted and T2-weighted imaging data and ADC value has the potential to improve specificity. In addition, the use of diffusion-weighted imaging in a standard breast MR imaging protocol may heighten sensitivity and thereby improve diagnostic accuracy. Standardization of diffusion-weighted imaging parameters is needed to allow comparison of multicenter studies and assessment of the clinical utility of diffusion-weighted imaging and ADC values in breast evaluation.

  9. Dynamic susceptibility contrast-enhanced perfusion MR imaging at 1.5 T predicts final infarct size in a rat stroke model.

    PubMed

    Chen, Feng; Suzuki, Yasuhiro; Nagai, Nobuo; Peeters, Ronald; Marchal, Guy; Ni, Yicheng

    2005-01-30

    The purpose of the present animal experiment was to determine whether source images from dynamic susceptibility contrast-enhanced perfusion weighted imaging (DSC-PWI) at a 1.5T MR scanner, performed early after photochemically induced thrombosis (PIT) of cerebral middle artery (MCA), is feasible to predict final cerebral infarct size in a rat stroke model. Fifteen rats were subjected to PIT of proximal MCA. T2 weighted imaging (T2WI), diffusion-weighted imaging (DWI), and contrast-enhanced PWI were obtained at 1 h and 24 h after MCA occlusion. The relative lesion size (RLS) was defined as lesion volume/brain volume x 100% and measured for MR images, and compared with the final RLS on the gold standard triphenyl tetrazolium chloride (TTC) staining at 24 h. One hour after MCA occlusion, the RLS with DSC-PWI was 24.9 +/- 6.3%, which was significantly larger than 17.6 +/- 4.8% with DWI (P < 0.01). At 24 h, the final RLS on TTC was 24.3 +/- 4.8%, which was comparable to 25.1 +/- 3.5%, 24.6 +/- 3.6% and 27.9 +/- 6.8% with T2WI, DWI and DSC-PWI respectively (P > 0.05). The fact that at 1 h after MCA occlusion only the displayed perfusion deficit was similar to the final infarct size on TTC (P > 0.05) suggests that early source images from DSC-PWI at 1.5T MR scanner is feasible to noninvasively predict the final infarct size in rat models of stroke.

  10. Lingering fat signals with CHESS in simultaneous imaging of both hands can be improved with rice pads in both 1.5T and 3.0T.

    PubMed

    Moriya, Susumu; Miki, Yukio; Kamishima, Tamotsu; Miyati, Tosiaki; Kanagaki, Mitsunori; Matsuno, Yukako; Yokobayashi, Tsuneo

    2013-09-01

    To investigate whether rice pads can eliminate lingering fat signals of the complex surface shape of both hands that occur with chemical shift selective (CHESS) at 1.5T and 3.0T. T1-weighted images were obtained with CHESS using 1.5T and 3.0T systems. The same imaging parameters were used with and without rice pads on the coronal plane of both hands in 10 healthy volunteers. The fat-suppression effects were classified into four categories and scored for images, and visual evaluations were performed by one radiologist and one radiologic technologist. At 1.5T, the mean evaluation score was 1.55 for images obtained without rice pads and 3.50 for images obtained with rice pads. At 3.0T, the mean evaluation score was 1.10 for images obtained without rice pads and 3.20 for images obtained with rice pads. With both systems, images obtained with the rice pads showed significantly better fat suppression effects than images obtained without rice pads (P<0.0001, P<0.0001). It was confirmed that lingering fat signals are eliminated and good fat-suppressed images are obtained with the use of rice pads at 1.5T and 3.0T. Rice pads are therefore useful with at 1.5T and 3.0T, which are currently becoming more widely used. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Comparison of Different Magnetic Resonance Cholangiography Techniques in Living Liver Donors Including Gd-EOB-DTPA Enhanced T1-Weighted Sequences

    PubMed Central

    Kinner, Sonja; Steinweg, Verena; Maderwald, Stefan; Radtke, Arnold; Sotiropoulos, Georgios; Forsting, Michael; Schroeder, Tobias

    2014-01-01

    Objectives Preoperative evaluation of potential living liver donors (PLLDs) includes the assessment of the biliary anatomy to avoid postoperative complications. Aim of this study was to compare T2-weighted (T2w) and Gd-EOB-DTPA enhanced T1-weighted (T1w) magnetic resonance cholangiography (MRC) techniques in the evaluation of PLLDs. Materials and Methods 30 PLLDs underwent MRC on a 1.5 T Magnetom Avanto (Siemens, Erlangen, Germany) using (A) 2D T2w HASTE (Half Fourier Acquisition Single Shot Turbo Spin Echo) fat saturated (fs) in axial plane, (B) 2D T2w HASTE fs thick slices in coronal plane, (C) free breathing 3D T2w TSE (turbo spin echo) RESTORE (high-resolution navigator corrected) plus (D) maximum intensity projections (MIPs), (E) T2w SPACE (sampling perfection with application optimized contrasts using different flip angle evolutions) plus (F) MIPs and (G) T2w TSE BLADE as well as Gd-EOB-DTPA T1w images without (G) and with (H) inversion recovery. Contrast enhanced CT cholangiography served as reference imaging modality. Two independent reviewers evaluated the biliary tract anatomy on a 5-point scale subjectively and objectively. Data sets were compared using a Mann-Whitney-U-test. Kappa values were also calculated. Results Source images and maximum intensity projections of 3D T2w TSE sequences (RESTORE and SPACE) proved to be best for subjective and objective evaluation directly followed by 2D HASTE sequences. Interobserver variabilities were good to excellent (k = 0.622–0.804). Conclusions 3D T2w sequences are essential for preoperative biliary tract evaluation in potential living liver donors. Furthermore, our results underline the value of different MRCP sequence types for the evaluation of the biliary anatomy in PLLDs including Gd-EOB-DTPA enhanced T1w MRC. PMID:25426932

  12. A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque.

    PubMed

    Lv, Peng; Dai, Yuanyuan; Lin, Jiang; Zhang, Weisheng; Liu, Hao; Liu, Hui; Tang, Xiao

    2017-03-01

    The aim of this study was to compare 3D T2-weighted sampling perfection with application optimized contrast using different flip angle evolutions (T2w SPACE) with conventional 2D T2w turbo-spin echo (TSE) in plaque imaging of carotid artery. 45 patients underwent 3.0-T MRI for carotid arteries imaging. MR sequences included T2w SPACE, T2w TSE, Time of flight (TOF) and T1-weighted (T1w) TSE. The signal intensity of intra-plaque hemorrhage (IPH), lipid-rich necrotic core (LRNC), and loose matrix (LM) were measured and their contrast ratios (CRs) against adjacent muscle were calculated. CRs from T2w SPACE and T2w TSE were compared to each other. CRs of LM, LRNC, and IPH measured on T2w SPACE were 1.74-3.04 (2.44), 0.98-1.66 (1.39), and 1.91-2.93 (2.51), respectively. CRs of LM, LRNC, and IPH on T2w TSE were 1.97-3.41 (2.44), 1.18-1.73 (1.43), and 2.26-3.75 (2.26), respectively. There was no significant difference of CR of the carotid plaques between T2w SPACE and T2w TSE (p = 0.455). Markedly significant differences of CRs were found between LM and LRNC (p < 0.001), and between LRNC and IPH (p < 0.001) on T2w SPACE and T2w TSE. T2w SPACE was comparable with conventional T2w TSE in characterization of carotid plaque.

  13. Engineered contrast agents in a single structure for T1-T2 dual magnetic resonance imaging.

    PubMed

    Cabrera-García, Alejandro; Checa-Chavarria, Elisa; Pacheco-Torres, Jesús; Bernabeu-Sanz, Ángela; Vidal-Moya, Alejandro; Rivero-Buceta, Eva; Sastre, Germán; Fernández, Eduardo; Botella, Pablo

    2018-04-05

    The development of contrast agents (CAs) for Magnetic Resonance Imaging (MRI) with T1-T2 dual-mode relaxivity requires the accurate assembly of T1 and T2 magnetic centers in a single structure. In this context, we have synthesized a novel hybrid material by monitoring the formation of Prussian Blue analogue Gd(H2O)4[Fe(CN)6] nanoparticles with tailored shape (from nanocrosses to nanorods) and size, and further protection with a thin and homogeneous silica coating through hydrolysis and polymerization of silicate at neutral pH. The resulting Gd(H2O)4[Fe(CN)6]@SiO2 magnetic nanoparticles are very stable in biological fluids. Interestingly, this combination of Gd and Fe magnetic centers closely packed in the crystalline network promotes a magnetic synergistic effect, which results in significant improvement of longitudinal relaxivity with regards to soluble Gd3+ chelates, whilst keeping the high transversal relaxivity inherent to the iron component. As a consequence, this material shows excellent activity as MRI CA, improving positive and negative contrasts in T1- and T2-weighted MR images, both in in vitro (e.g., phantom) and in vivo (e.g., Sprague-Dawley rats) models. In addition, this hybrid shows a high biosafety profile and has strong ability to incorporate organic molecules on the surface with variable functionality, displaying great potential for further clinical application.

  14. Histogram Profiling of Postcontrast T1-Weighted MRI Gives Valuable Insights into Tumor Biology and Enables Prediction of Growth Kinetics and Prognosis in Meningiomas.

    PubMed

    Gihr, Georg Alexander; Horvath-Rizea, Diana; Kohlhof-Meinecke, Patricia; Ganslandt, Oliver; Henkes, Hans; Richter, Cindy; Hoffmann, Karl-Titus; Surov, Alexey; Schob, Stefan

    2018-06-14

    Meningiomas are the most frequently diagnosed intracranial masses, oftentimes requiring surgery. Especially procedure-related morbidity can be substantial, particularly in elderly patients. Hence, reliable imaging modalities enabling pretherapeutic prediction of tumor grade, growth kinetic, realistic prognosis, and-as a consequence-necessity of surgery are of great value. In this context, a promising diagnostic approach is advanced analysis of magnetic resonance imaging data. Therefore, our study investigated whether histogram profiling of routinely acquired postcontrast T1-weighted images is capable of separating low-grade from high-grade lesions and whether histogram parameters reflect Ki-67 expression in meningiomas. Pretreatment T1-weighted postcontrast volumes of 44 meningioma patients were used for signal intensity histogram profiling. WHO grade, tumor volume, and Ki-67 expression were evaluated. Comparative and correlative statistics investigating the association between histogram profile parameters and neuropathology were performed. None of the investigated histogram parameters revealed significant differences between low-grade and high-grade meningiomas. However, significant correlations were identified between Ki-67 and the histogram parameters skewness and entropy as well as between entropy and tumor volume. Contrary to previously reported findings, pretherapeutic postcontrast T1-weighted images can be used to predict growth kinetics in meningiomas if whole tumor histogram analysis is employed. However, no differences between distinct WHO grades were identifiable in out cohort. As a consequence, histogram analysis of postcontrast T1-weighted images is a promising approach to obtain quantitative in vivo biomarkers reflecting the proliferative potential in meningiomas. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Gadolinium-based nanoparticles for highly efficient T1-weighted magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Lim, Eun-Kyung; Kang, Byunghoon; Choi, Yuna; Jang, Eunji; Han, Seungmin; Lee, Kwangyeol; Suh, Jin-Suck; Haam, Seungjoo; Huh, Yong-Min

    2014-06-01

    We developed Pyrene-Gadolinium (Py-Gd) nanoparticles as pH-sensitive magnetic resonance imaging (MRI) contrast agents capable of showing a high-Mr signal in cancer-specific environments, such as acidic conditions. Py-Gd nanoparticles were prepared by coating Py-Gd, which is a complex of gadolinium with pyrenyl molecules, with pyrenyl polyethyleneglycol PEG using a nano-emulsion method. These particles show better longitudinal relaxation time (T1) MR signals in acidic conditions than they do in neutral conditions. Furthermore, the particles exhibit biocompatibility and MR contrast effects in both in vitro and in vivo studies. From these results, we confirm that Py-Gd nanoparticles have the potential to be applied for accurate cancer diagnosis and therapy.

  16. Stimulated echo diffusion tensor imaging and SPAIR T2 -weighted imaging in chronic exertional compartment syndrome of the lower leg muscles.

    PubMed

    Sigmund, Eric E; Sui, Dabang; Ukpebor, Obehi; Baete, Steven; Fieremans, Els; Babb, James S; Mechlin, Michael; Liu, Kecheng; Kwon, Jane; McGorty, KellyAnne; Hodnett, Philip A; Bencardino, Jenny

    2013-11-01

    To evaluate the performance of diffusion tensor imaging (DTI) in the evaluation of chronic exertional compartment syndrome (CECS) as compared to T2 -weighted (T2w) imaging. Using an Institutional Review Board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant protocol, spectral adiabatic inversion recovery (SPAIR) T2w imaging and stimulated echo DTI were applied to eight healthy volunteers and 14 suspected CECS patients before and after exertion. Longitudinal and transverse diffusion eigenvalues, mean diffusivity (MD), and fractional anisotropy (FA) were measured in seven calf muscle compartments, which in patients were classified by their response on T2w: normal (<20% change), and CECS (>20% change). Mixed model analysis of variance compared subject groups and compartments in terms of response factors (post/pre-exercise ratios) of DTI parameters. All diffusivities significantly increased (P < 0.0001) and FA decreased (P = 0.0014) with exercise. Longitudinal diffusion responses were significantly smaller than transversal diffusion responses (P < 0.0001). Nineteen of 98 patient compartments were classified as CECS on T2w. MD increased by 3.8 ± 3.4% (volunteer), 7.4 ± 4.2% (normal), and 9.1 ± 7.0% (CECS) with exercise. DTI shows promise as an ancillary imaging method in the diagnosis and understanding of the pathophysiology in CECS. Future studies may explore its utility in predicting response to treatment. Copyright © 2013 Wiley Periodicals, Inc.

  17. Magnetic resonance T1 gradient-echo imaging in hepatolithiasis.

    PubMed

    Safar, F; Kamura, T; Okamuto, K; Sasai, K; Gejyo, F

    2005-01-01

    We examined the role of magnetic resonance T1-weighted gradient-echo (MRT1-GE) imaging in hepatolithiasis. MRT1-GE, precontrast computed tomography (CT), and magnetic resonance cholangiopancreatography (MRCP) of 10 patients with hepatolithiasis were compared for their diagnostic accuracies in the detection and localization of intrahepatic calculi. The diagnosis of hepatolithiasis was confirmed by surgery. For localization of the stone, we divided the bile ducts into six areas: right and left hepatic ducts and bile ducts of the lateral, medial, right anterior, and right posterior segments of the liver. Chemical analysis of the stones was performed in eight patients. The total number of segments proved by surgery to contain stones was 18. Although not significantly different, the sensitivity of MRT1-GE was 77.8% (14 of 18 segments), higher than that of MRCP (66.7%, 12 of 18 segments) and that of CT (50%, nine of 18 segments). The sensitivity of magnetic resonance imaging (MRCP + MRT1) was significantly higher than that of CT (p < 0.01). Multiple logistic regression analysis showed that the result of surgery was significantly affected only by the result of magnetic resonance imaging. On MRT1-GE, all the depicted stones appeared as high-intensity signal areas within the low-intensity bile duct irrespective of their chemical composition. MRT1-GE imaging provides complementary information concerning hepatolithiasis.

  18. Automatic Brain Tumor Detection in T2-weighted Magnetic Resonance Images

    NASA Astrophysics Data System (ADS)

    Dvořák, P.; Kropatsch, W. G.; Bartušek, K.

    2013-10-01

    This work focuses on fully automatic detection of brain tumors. The first aim is to determine, whether the image contains a brain with a tumor, and if it does, localize it. The goal of this work is not the exact segmentation of tumors, but the localization of their approximate position. The test database contains 203 T2-weighted images of which 131 are images of healthy brain and the remaining 72 images contain brain with pathological area. The estimation, whether the image shows an afflicted brain and where a pathological area is, is done by multi resolution symmetry analysis. The first goal was tested by five-fold cross-validation technique with 100 repetitions to avoid the result dependency on sample order. This part of the proposed method reaches the true positive rate of 87.52% and the true negative rate of 93.14% for an afflicted brain detection. The evaluation of the second part of the algorithm was carried out by comparing the estimated location to the true tumor location. The detection of the tumor location reaches the rate of 95.83% of correct anomaly detection and the rate 87.5% of correct tumor location.

  19. Pulmonary nodule detection in oncological patients - Value of respiratory-triggered, periodically rotated overlapping parallel T2-weighted imaging evaluated with PET/CT-MR.

    PubMed

    de Galiza Barbosa, Felipe; Geismar, Jan Henning; Delso, Gaspar; Messerli, Michael; Huellner, Martin; Stolzmann, Paul; Veit-Haibach, Patrick

    2018-01-01

    To prospectively evaluate the detection and conspicuity of pulmonary nodules in an oncological population, using a tri-modality PET/CT-MR protocol including a respiration-gated T2-PROPELLER sequence for possible integration into a simultaneous PET/MR protocol. 149 patients referred for staging of malignancy were prospectively enrolled in this single-center study. Imaging was performed on a tri-modality PET/CT-MR setup and was comprised of PET/CT and 3T-MR imaging with 3D dual-echo GRE pulse sequence (Dixon) and an axial respiration-gated T2-weighted PROPELLER (T2-P) sequence. Images were assessed for presence, conspicuity, size and interpretation of the pulmonary parenchymal nodules. McNemar's test was used to evaluate paired differences in nodule detection rates between MR and CT from PET/CT. The correlation of pulmonary nodule size in CT and MR imaging was assessed using Pearson correlation coefficient. 299 pulmonary nodules were detected on PET/CT. The detectability was significantly higher on T2-P (60%, p<0.01) compared to T1-weighted Dixon-type sequences (16.1-37.8%). T2-P had a significantly higher detection rate among FDG-positive (92.4%) and among confirmed malignant nodules (75.9%) compared to T1-Dixon. Nodules <10mm were detected less often by MR sequences than by CT (p < 0.01). However, nodules >10mm were detected equally well with T2-P (92.2%) and CT (p >0.05). In a per-patient analysis, there was no significant change in the clinical interpretation of the nodules detected with T2-P and CT. Despite the overall lower detection rate compared with CT, the free-breathing respiratory gating T2-w sequence showed higher detectability in all evaluated categories compared to breath-hold T1-weighted MR sequences. Specifically, the T2-P was found to be not statistically different from CT in FDG-positive nodules, in detection of nodules >10mm and concerning conspicuity of pulmonary nodules. Overall, the additional time investment into T2-P seems to be justified

  20. A review of technical aspects of T1-weighted dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in human brain tumors.

    PubMed

    Bergamino, M; Bonzano, L; Levrero, F; Mancardi, G L; Roccatagliata, L

    2014-09-01

    In the last few years, several imaging methods, such as magnetic resonance imaging (MRI) and computed tomography, have been used to investigate the degree of blood-brain barrier (BBB) permeability in patients with neurological diseases including multiple sclerosis, ischemic stroke, and brain tumors. One promising MRI method for assessing the BBB permeability of patients with neurological diseases in vivo is T1-weighted dynamic contrast-enhanced (DCE)-MRI. Here we review the technical issues involved in DCE-MRI in the study of human brain tumors. In the first part of this paper, theoretical models for the DCE-MRI analysis will be described, including the Toft-Kety models, the adiabatic approximation to the tissue homogeneity model and the two-compartment exchange model. These models can be used to estimate important kinetic parameters related to BBB permeability. In the second part of this paper, details of the data acquisition, issues related to the arterial input function, and procedures for DCE-MRI image analysis are illustrated. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Reticular Appearance on Gadolinium-enhanced T1- and Diffusion-weighted MRI, and Low Apparent Diffusion Coefficient Values in Microcystic Meningioma Cysts.

    PubMed

    Terada, Yukinori; Toda, Hiroki; Okumura, Ryosuke; Ikeda, Naokado; Yuba, Yoshiaki; Katayama, Toshiro; Iwasaki, Koichi

    2018-03-01

    Microcystic meningioma, a rare meningioma subtype, can present diagnostic difficulty. We aimed to investigate the historadiological properties of microcystic meningioma using conventional magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) analysis. We retrospectively analyzed conventional MRI and DWI results of six microcystic meningioma cases by examining their appearance and determining their apparent diffusion coefficient (ADC) values. The ADC values of the intratumoral components were normalized with ADC values of the cerebrospinal fluid in the lateral ventricle (ADC ratios). As cystic formations are frequently associated with microcystic meningiomas, their MRI characteristics were compared with the imaging data from 11 cystic meningiomas of non-microcystic subtypes. We found that cysts in microcystic meningioma tended to have a reticular appearance on DWI, as they did on gadolinium-enhanced T1-weighted imaging. Additionally, these reticular cysts had significantly lower ADC ratios than microcystic non-reticular and non-microcystic cysts. These DWI characteristics likely reflect the histological properties of microcystic meningioma. A reticular appearance on gadolinium-enhanced T1-weighted MRI and DWI, and cyst formation with relatively low ADC values can be diagnostic markers of microcystic meningiomas.

  2. T2-Weighted Dixon Turbo Spin Echo for Accelerated Simultaneous Grading of Whole-Body Skeletal Muscle Fat Infiltration and Edema in Patients With Neuromuscular Diseases.

    PubMed

    Schlaeger, Sarah; Klupp, Elisabeth; Weidlich, Dominik; Cervantes, Barbara; Foreman, Sarah C; Deschauer, Marcus; Schoser, Benedikt; Katemann, Christoph; Kooijman, Hendrik; Rummeny, Ernst J; Zimmer, Claus; Kirschke, Jan S; Karampinos, Dimitrios C

    2018-04-02

    The assessment of fatty infiltration and edema in the musculature of patients with neuromuscular diseases (NMDs) typically requires the separate performance of T1-weighted and fat-suppressed T2-weighted sequences. T2-weighted Dixon turbo spin echo (TSE) enables the generation of T2-weighted fat- and water-separated images, which can be used to assess both pathologies simultaneously. The present study examines the diagnostic performance of T2-weighted Dixon TSE compared with the standard sequences in 10 patients with NMDs and 10 healthy subjects. Whole-body magnetic resonance imaging was performed including T1-weighted Dixon fast field echo, T2-weighted short-tau inversion recovery, and T2-weighted Dixon TSE. Fatty infiltration and intramuscular edema were rated by 2 radiologists using visual semiquantitative rating scales. To assess intermethod and interrater agreement, weighted Cohen's κ coefficients were calculated. The ratings of fatty infiltration showed high intermethod and high interrater agreement (T1-weighted Dixon fast field echo vs T2-weighted Dixon TSE fat image). The evaluation of edematous changes showed high intermethod and good interrater agreement (T2-weighted short-tau inversion recovery vs T2-weighted Dixon TSE water image). T2-weighted Dixon TSE imaging is an alternative for accelerated simultaneous grading of whole-body skeletal muscle fat infiltration and edema in patients with NMDs.

  3. Local staging and assessment of colon cancer with 1.5-T magnetic resonance imaging

    PubMed Central

    Blake, Helena; Jeyadevan, Nelesh; Abulafi, Muti; Swift, Ian; Toomey, Paul; Brown, Gina

    2016-01-01

    Objective: The aim of this study was to assess the accuracy of 1.5-T MRI in the pre-operative local T and N staging of colon cancer and identification of extramural vascular invasion (EMVI). Methods: Between 2010 and 2012, 60 patients with adenocarcinoma of the colon were prospectively recruited at 2 centres. 55 patients were included for final analysis. Patients received pre-operative 1.5-T MRI with high-resolution T2 weighted, gadolinium-enhanced T1 weighted and diffusion-weighted images. These were blindly assessed by two expert radiologists. Accuracy of the T-stage, N-stage and EMVI assessment was evaluated using post-operative histology as the gold standard. Results: Results are reported for two readers. Identification of T3 disease demonstrated an accuracy of 71% and 51%, sensitivity of 74% and 42% and specificity of 74% and 83%. Identification of N1 disease demonstrated an accuracy of 57% for both readers, sensitivity of 26% and 35% and specificity of 81% and 74%. Identification of EMVI demonstrated an accuracy of 74% and 69%, sensitivity 63% and 26% and specificity 80% and 91%. Conclusion: 1.5-T MRI achieved a moderate accuracy in the local evaluation of colon cancer, but cannot be recommended to replace CT on the basis of this study. Advances in knowledge: This study confirms that MRI is a viable alternative to CT for the local assessment of colon cancer, but this study does not reproduce the very high accuracy reported in the only other study to assess the accuracy of MRI in colon cancer staging. PMID:27226219

  4. High spatial resolution diffusion weighted imaging on clinical 3 T MRI scanners using multislab spiral acquisitions

    PubMed Central

    Holtrop, Joseph L.; Sutton, Bradley P.

    2016-01-01

    Abstract. A diffusion weighted imaging (DWI) approach that is signal-to-noise ratio (SNR) efficient and can be applied to achieve sub-mm resolutions on clinical 3 T systems was developed. The sequence combined a multislab, multishot pulsed gradient spin echo diffusion scheme with spiral readouts for imaging data and navigators. Long data readouts were used to keep the number of shots, and hence total imaging time, for the three-dimensional acquisition short. Image quality was maintained by incorporating a field-inhomogeneity-corrected image reconstruction to remove distortions associated with long data readouts. Additionally, multiple shots were required for the high-resolution images, necessitating motion induced phase correction through the use of efficiently integrated navigator data. The proposed approach is compared with two-dimensional (2-D) acquisitions that use either a spiral or a typical echo-planar imaging (EPI) acquisition to demonstrate the improved SNR efficiency. The proposed technique provided 71% higher SNR efficiency than the standard 2-D EPI approach. The adaptability of the technique to achieve high spatial resolutions is demonstrated by acquiring diffusion tensor imaging data sets with isotropic resolutions of 1.25 and 0.8 mm. The proposed approach allows for SNR-efficient sub-mm acquisitions of DWI data on clinical 3 T systems. PMID:27088107

  5. Tissue-Specific Imaging Is a Robust Methodology to Differentiate In Vivo T1 Black Holes with Advanced Multiple Sclerosis–Induced Damage

    PubMed Central

    Riva, M.; Ikonomidou, V.N.; Ostuni, J.J.; van Gelderen, P.; Auh, S.; Ohayon, J.M.; Tovar-Moll, F.; Richert, N.D.; Duyn, J.H.; Bagnato, F.

    2017-01-01

    BACKGROUND AND PURPOSE Brains of patients with multiple sclerosis (MS) characteristically have “black holes” (BHs), hypointense lesions on T1-weighted (T1W) spin-echo (SE) images. Although conventional MR imaging can disclose chronic BHs (CBHs), it cannot stage the degree of their pathologic condition. Tissue-specific imaging (TSI), a recently introduced MR imaging technique, allows selective visualization of white matter (WM), gray matter (GM), and CSF on the basis of T1 values of classes of tissue. We investigated the ability of TSI-CSF to separate CBHs with longer T1 values, which likely represent lesions containing higher levels of destruction and unbound water. MATERIALS AND METHODS Eighteen patients with MS, who had already undergone MR imaging twice (24 months apart) on a 1.5T scanner, underwent a 3T MR imaging examination. Images acquired at 1.5T included sequences of precontrast and postcontrast T1W SE, T2-weighted (T2W) SE, and magnetization transfer (MT). Sequences obtained at 3T included precontrast and postcontrast T1W SE, T2W SE, T1 inversion recovery prepared fast spoiled gradient recalled-echo (IR-FSPGR) and TSI. A BH on the 3T-IR-FSPGR was defined as a CBH if seen as a hypointense, nonenhancing lesion with a corresponding T2 abnormality for at least 24 months. CBHs were separated into 2 groups: those visible as hyperintensities on TSI-CSF (group A), and those not appearing on the TSI-CSF (group B). RESULTS Mean MT ratios of group-A lesions (0.22 ± 0.06, 0.13–0.35) were lower (F1,13 = 60.39; P < .0001) than those of group-B lesions (0.32 ± 0.03, 0.27–0.36). CONCLUSIONS Group-A lesions had more advanced tissue damage; thus, TSI is a potentially valuable method for qualitative and objective identification. PMID:19406765

  6. T2-weighted MRI of the upper abdomen: comparison of four fat-suppressed T2-weighted sequences including PROPELLER (BLADE) technique.

    PubMed

    Bayramoglu, Sibel; Kilickesmez, Ozgür; Cimilli, Tan; Kayhan, Arda; Yirik, Gülseren; Islim, Filiz; Alibek, Sedat

    2010-03-01

    The aim of this study was to compare four different fat-suppressed T2-weighted sequences with different techniques with regard to image quality and lesion detection in upper abdominal magnetic resonance imaging (MRI) scans. Thirty-two consecutive patients referred for upper abdominal MRI for the evaluation of various suspected pathologies were included in this study. Different T2-weighted sequences (free-breathing navigator-triggered turbo spin-echo [TSE], free-breathing navigator-triggered TSE with restore pulse (RP), breath-hold TSE with RP, and free-breathing navigator-triggered TSE with RP using the periodically rotated overlapping parallel lines with enhanced reconstruction technique [using BLADE, a Siemens implementation of this technique]) were used on all patients. All images were assessed independently by two radiologists. Assessments of motion artifacts; the edge sharpness of the liver, pancreas, and intrahepatic vessels; depictions of the intrahepatic vessels; and overall image quality were performed qualitatively. Quantitative analysis was performed by calculation of the signal-to-noise ratios for liver tissue and gallbladder as well as contrast-to-noise ratios of liver to spleen. Liver and gallbladder signal-to-noise ratios as well as liver to spleen contrast-to-noise ratios were significantly higher (P < .05) for the BLADE technique compared to all other sequences. In qualitative analysis, the severity of motion artifacts was significantly lower with T2-weighted free-breathing navigator-triggered BLADE sequences compared to other sequences (P < .01). The edge sharpness of the liver, pancreas, and intrahepatic vessels; depictions of the intrahepatic vessels; and overall image quality were significantly better with the BLADE sequence (P < .05). The T2-weighted free-breathing navigator-triggered TSE sequence with the BLADE technique is a promising approach for reducing motion artifacts and improving image quality in upper abdominal MRI scans.

  7. Magnetic resonance characteristics and susceptibility weighted imaging of the brain in gadolinium encephalopathy.

    PubMed

    Samardzic, Dejan; Thamburaj, Krishnamoorthy

    2015-01-01

    To report the brain imaging features on magnetic resonance imaging (MRI) in inadvertent intrathecal gadolinium administration. A 67-year-old female with gadolinium encephalopathy from inadvertent high dose intrathecal gadolinium administration during an epidural steroid injection was studied with multisequence 3T MRI. T1-weighted imaging shows pseudo-T2 appearance with diffusion of gadolinium into the brain parenchyma, olivary bodies, and membranous labyrinth. Nulling of cerebrospinal fluid (CSF) signal is absent on fluid attenuation recovery (FLAIR). Susceptibility-weighted imaging (SWI) demonstrates features similar to subarachnoid hemorrhage. CT may demonstrate a pseudo-cerebral edema pattern given the high attenuation characteristics of gadolinium. Intrathecal gadolinium demonstrates characteristic imaging features on MRI of the brain and may mimic subarachnoid hemorrhage on susceptibility-weighted imaging. Identifying high dose gadolinium within the CSF spaces on MRI is essential to avoid diagnostic and therapeutic errors. Copyright © 2013 by the American Society of Neuroimaging.

  8. Susceptibility-weighted imaging at 7 T: Improved diagnosis of cerebral cavernous malformations and associated developmental venous anomalies☆☆☆

    PubMed Central

    Frischer, Josa M.; Göd, Sabine; Gruber, Andreas; Saringer, Walter; Grabner, Günther; Gatterbauer, Brigitte; Kitz, Klaus; Holzer, Sabrina; Kronnerwetter, Claudia; Hainfellner, Johannes A.; Knosp, Engelbert; Trattnig, Siegfried

    2012-01-01

    Background and aim In the diagnosis of cerebral cavernous malformations (CCMs) magnetic resonance imaging is established as the gold standard. Conventional MRI techniques have their drawbacks in the diagnosis of CCMs and associated venous malformations (DVAs). The aim of our study was to evaluate susceptibility weighted imaging SWI for the detection of CCM and associated DVAs at 7 T in comparison with 3 T. Patients and methods 24 patients (14 female, 10 male; median age: 38.3 y (21.1 y–69.1 y) were included in the study. Patients enrolled in the study received a 3 T and a 7 T MRI on the same day. The following sequences were applied on both field strengths: a T1 weighted 3D GRE sequence (MP-RAGE) and a SWI sequence. After obtaining the study MRIs, eleven patients underwent surgery and 13 patients were followed conservatively or were treated radio-surgically. Results Patients initially presented with haemorrhage (n = 4, 16.7%), seizures (n = 2, 8.3%) or other neurology (n = 18, 75.0%). For surgical resected lesions histopathological findings verified the diagnosis of CCMs. A significantly higher number of CCMs was diagnosed at 7 T SWI sequences compared with 3 T SWI (p < 0.05). Additionally diagnosed lesions on 7 T MRI were significantly smaller compared to the initial lesions on 3 T MRIs (p < 0.001). Further, more associated DVAs were diagnosed at 7 T MRI compared to 3 T MRI. Conclusion SWI sequences at ultra-high-field MRI improve the diagnosis of CCMs and associated DVAs and therefore add important pre-operative information. PMID:24179744

  9. PCA based clustering for brain tumor segmentation of T1w MRI images.

    PubMed

    Kaya, Irem Ersöz; Pehlivanlı, Ayça Çakmak; Sekizkardeş, Emine Gezmez; Ibrikci, Turgay

    2017-03-01

    Medical images are huge collections of information that are difficult to store and process consuming extensive computing time. Therefore, the reduction techniques are commonly used as a data pre-processing step to make the image data less complex so that a high-dimensional data can be identified by an appropriate low-dimensional representation. PCA is one of the most popular multivariate methods for data reduction. This paper is focused on T1-weighted MRI images clustering for brain tumor segmentation with dimension reduction by different common Principle Component Analysis (PCA) algorithms. Our primary aim is to present a comparison between different variations of PCA algorithms on MRIs for two cluster methods. Five most common PCA algorithms; namely the conventional PCA, Probabilistic Principal Component Analysis (PPCA), Expectation Maximization Based Principal Component Analysis (EM-PCA), Generalize Hebbian Algorithm (GHA), and Adaptive Principal Component Extraction (APEX) were applied to reduce dimensionality in advance of two clustering algorithms, K-Means and Fuzzy C-Means. In the study, the T1-weighted MRI images of the human brain with brain tumor were used for clustering. In addition to the original size of 512 lines and 512 pixels per line, three more different sizes, 256 × 256, 128 × 128 and 64 × 64, were included in the study to examine their effect on the methods. The obtained results were compared in terms of both the reconstruction errors and the Euclidean distance errors among the clustered images containing the same number of principle components. According to the findings, the PPCA obtained the best results among all others. Furthermore, the EM-PCA and the PPCA assisted K-Means algorithm to accomplish the best clustering performance in the majority as well as achieving significant results with both clustering algorithms for all size of T1w MRI images. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Diffusion weighted imaging with background body signal suppression / T2 image fusion in magnetic resonance mammography for breast cancer diagnosis.

    PubMed

    Nechifor-Boilă, I A; Bancu, S; Buruian, M; Charlot, M; Decaussin-Petrucci, M; Krauth, J-S; Nechifor-Boilă, A C; Borda, A

    2013-01-01

    Dynamic Contrast-Enhanced Magnetic Resonance Mammography (DCE-MRM) represents the most sensitive examination for breast cancer (BC) diagnosis. However literature data reports very inhomogeneous specificity. The aim of our study was to evaluate the clinical efficiency of a new MRM technique - diffusion weighted imaging with background body signal suppression T2 image fusion in BC diagnosis, compared to DCE-MRM. We retrospectively analyzed 50 consecutive DCE-MRM examinations with DWIBS sequence from the archives of the Department of Radiology, Lyon Sud Hospital, (02.2010- 02.2011), summing up to 64 breast lesions. Fusions were created using the Osirix software from the DWIBS images (b=1000 s mm2) and their T2 correspondents. Interpretation was performed using an adapted BI-RADS system. The final histopathological examination or a minimum 6-months follow-up served as gold standard. Out of the 64 examined breast lesions, 35(54.7%) were classified as malignant by DCE-MRM and 24(37.5%) cases by DWIBS T2, respectively. Thus the DWIBS T2 fusion had a Sensitivity of 62.5%(95%CI:35.4-84.8) and a Specificity of 70.8%(95%CI:55.9-83.3) while DCE-MRM had a higher Sensitivity: 87.5%(95%CI:61.6-98.4) but a lower Specificity: 56.2%(95%CI:41.1-70.5). DWIBS T2 fusion is an innovative MRM technique, with a specificity superior to DCE-MRM, showing a large potential for improving the clinical efficiency of classical MRM. Celsius.

  11. Cardiac T1 Imaging

    PubMed Central

    Jerosch-Herold, Michael; Kwong, Raymond Y.

    2014-01-01

    T1 mapping of the heart has evolved into a valuable tool to evaluate myocardial tissue properties, with or without contrast injection, including assessment of myocardial edema and free water content, extra-cellular volume (expansion), and most recently cardiomyocyte hypertrophy. The MRI pulse sequence techniques developed for these applications have had to address at least two important considerations for cardiac applications: measure magnetization inversion recoveries during cardiac motion with sufficient temporal resolution for the shortest expected T1 values, and, secondly, obtain these measurements within a time during which a patient can comfortably suspend breathing. So-called Look-Locker techniques, and variants thereof, which all sample multiple points of a magnetization recovery after each magnetization preparation have therefore become a mainstay in this field. The rapid pace of advances and new findings based on cardiac T1 mapping for assessment of diffuse fibrosis, or myocardial edema show that these techniques enrich the capabilities of MRI for myocardial tissue profiling, which is arguably unmatched by other cardiac imaging modalities. PMID:24509619

  12. Effectiveness of a Rapid Lumbar Spine MRI Protocol Using 3D T2-Weighted SPACE Imaging Versus a Standard Protocol for Evaluation of Degenerative Changes of the Lumbar Spine.

    PubMed

    Sayah, Anousheh; Jay, Ann K; Toaff, Jacob S; Makariou, Erini V; Berkowitz, Frank

    2016-09-01

    Reducing lumbar spine MRI scanning time while retaining diagnostic accuracy can benefit patients and reduce health care costs. This study compares the effectiveness of a rapid lumbar MRI protocol using 3D T2-weighted sampling perfection with application-optimized contrast with different flip-angle evolutions (SPACE) sequences with a standard MRI protocol for evaluation of lumbar spondylosis. Two hundred fifty consecutive unenhanced lumbar MRI examinations performed at 1.5 T were retrospectively reviewed. Full, rapid, and complete versions of each examination were interpreted for spondylotic changes at each lumbar level, including herniations and neural compromise. The full examination consisted of sagittal T1-weighted, T2-weighted turbo spin-echo (TSE), and STIR sequences; and axial T1- and T2-weighted TSE sequences (time, 18 minutes 40 seconds). The rapid examination consisted of sagittal T1- and T2-weighted SPACE sequences, with axial SPACE reformations (time, 8 minutes 46 seconds). The complete examination consisted of the full examination plus the T2-weighted SPACE sequence. Sensitivities and specificities of the full and rapid examinations were calculated using the complete study as the reference standard. The rapid and full studies had sensitivities of 76.0% and 69.3%, with specificities of 97.2% and 97.9%, respectively, for all degenerative processes. Rapid and full sensitivities were 68.7% and 66.3% for disk herniation, 85.2% and 81.5% for canal compromise, 82.9% and 69.1% for lateral recess compromise, and 76.9% and 69.7% for foraminal compromise, respectively. Isotropic SPACE T2-weighted imaging provides high-quality imaging of lumbar spondylosis, with multiplanar reformatting capability. Our SPACE-based rapid protocol had sensitivities and specificities for herniations and neural compromise comparable to those of the protocol without SPACE. This protocol fits within a 15-minute slot, potentially reducing costs and discomfort for a large subgroup of

  13. Fluorescence lifetime imaging of lipids during 3T3-L1 cell differentiation

    NASA Astrophysics Data System (ADS)

    Song, Young Sik; Won, Young Jae; Lee, Sang-Hak; Kim, Dug Young

    2014-03-01

    Obesity is becoming a big health problem in these days. Since increased body weight is due to increased number and size of the triglyceride-storing adipocytes, many researchers are working on differentiation conditions and processes of adipocytes. Adipocytes also work as regulators of whole-body energy homeostasis by secreting several proteins that regulate processes as diverse as haemostasis, blood pressure, immune function, angiogenesis and energy balance. 3T3-L1 cells are widely used cell line for studying adipogenesis because it can differentiate into an adipocyte-like phenotype under appropriate conditions. In this paper, we propose an effective fluorescence lifetime imaging technique which can easily distinguish lipids in membrane and those in lipid droplets. Nile red dyes are attached to lipids in 3T3-L1 cells. Fluorescence lifetime images were taken for 2 week during differentiation procedure of 3T3-L1 cells into adipocytes. We used 488 nm pulsed laser with 5MHz repetition rate and emission wavelength is 520 nm of Nile Red fluorescent dye. Results clearly show that the lifetime of Nile red in lipid droplets are smaller than those in cell membrane. Our results suggest that fluorescence lifetime imaging can be a very powerful tool to monitor lipid droplet formation in adipocytes from 3T3-L1 cells.

  14. Stability of polyelectrolyte-coated iron nanoparticles for T2-weighted magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    McGrath, Andrew J.; Dolan, Ciaran; Cheong, Soshan; Herman, David A. J.; Naysmith, Briar; Zong, Fangrong; Galvosas, Petrik; Farrand, Kathryn J.; Hermans, Ian F.; Brimble, Margaret; Williams, David E.; Jin, Jianyong; Tilley, Richard D.

    2017-10-01

    Iron nanoparticles are highly-effective magnetic nanoparticles for T2 magnetic resonance imaging (MRI). However, the stability of their magnetic properties is dependent on good protection of the iron core from oxidation in aqueous media. Here we report the synthesis of custom-synthesized phosphonate-grafted polyelectrolytes (PolyM3) of various chain lengths, for efficient coating of iron nanoparticles with a native iron oxide shell. The size of the nanoparticle-polyelectrolyte assemblies was investigated by transmission electron microscopy and dynamic light scattering, while surface attachment was confirmed by Fourier transform infrared spectroscopy. Low cytotoxicity was observed for each of the nanoparticle-polyelectrolyte ("Fe-PolyM3") assemblies, with good cell viability (>80%) remaining up to 100 μg mL-1 Fe in HeLa cells. When applied in T2-weighted MRI, corresponding T2 relaxivities (r2) of the Fe-PolyM3 assemblies were found to be dependent on the chain length of the polyelectrolyte. A significant increase in contrast was observed when polyelectrolyte chain length was increased from 6 to 65 repeating units, implying a critical chain length required for stabilization of the α-Fe nanoparticle core.

  15. Diagnosis of hepatic metastasis: comparison of respiration-triggered diffusion-weighted echo-planar MRI and five t2-weighted turbo spin-echo sequences.

    PubMed

    Bruegel, Melanie; Gaa, Jochen; Waldt, Simone; Woertler, Klaus; Holzapfel, Konstantin; Kiefer, Berthold; Rummeny, Ernst J

    2008-11-01

    The purpose of this study was to compare the value of respiration-triggered diffusion-weighted (DW) single-shot echo-planar MRI (EPI) and five variants of T2-weighted turbo spin-echo (TSE) sequences in the diagnosis of hepatic metastasis. Fifty-two patients with extrahepatic primary malignant tumors underwent 1.5-T MRI that included DW EPI and the following variants of T2-weighted TSE techniques: breath-hold fat-suppressed HASTE, breath-hold fat-supressed TSE, respiration-triggered fat-suppressed TSE, breath-hold STIR, and respiration-triggered STIR. Images were reviewed independently by two blinded observers who used a 5-point confidence scale to identify lesions. Results were correlated with surgical and histopathologic findings and follow-up imaging findings. The accuracy of each technique was measured with free-response receiver operating characteristic analysis. A total of 118 hepatic metastatic lesions (mean diameter, 12.8 mm; range, 3-84 mm) were evaluated. Accuracy values were higher (p < 0.001) with DW EPI (0.91-0.92) than with the T2-weighted TSE techniques (0.47-0.67). Imaging with the HASTE sequence (0.47-0.52) was less accurate (p < 0.05) than imaging with the breath-hold TSE, breath-hold STIR, respiration-triggered TSE, and respiration-triggered STIR sequences (0.59-0.67). Sensitivity was higher (p < 0.001) with DW EPI (0.88-0.91) than with T2-weighted TSE techniques (0.45-0.62). For small (< or = 10 mm) metastatic lesions only, the differences in sensitivity between DW EPI (0.85) and T2-weighted TSE techniques (0.26-0.44) were even more pronounced. DW EPI was more sensitive and more accurate than imaging with T2-weighted TSE techniques. Because of the black-blood effect on vessels and low susceptibility to motion artifacts, DW EPI was particularly useful for the detection of small (< or = 10 mm) metastatic lesions.

  16. Artifacts correction for T1rho imaging with constant amplitude spin-lock

    NASA Astrophysics Data System (ADS)

    Chen, Weitian

    2017-01-01

    T1rho imaging with constant amplitude spin-lock is prone to artifacts in the presence of B1 RF and B0 field inhomogeneity. Despite significant technological progress, improvements on the robustness of constant amplitude spin-lock are necessary in order to use it for routine clinical practice. This work proposes methods to simultaneously correct for B1 RF and B0 field inhomogeneity in constant amplitude spin-lock. By setting the maximum B1 amplitude of the excitation adiabatic pulses equal to the expected constant amplitude spin-lock frequency, the spins become aligned along the effective field throughout the spin-lock process. This results in T1rho-weighted images free of artifacts, despite the spatial variation of the effective field caused by B1 RF and B0 field inhomogeneity. When the pulse is long, the relaxation effect during the adiabatic half passage may result in a non-negligible error in the mono-exponential relaxation model. A two-acquisition approach is presented to solve this issue. Simulation, phantom, and in-vivo scans demonstrate the proposed methods achieve superior image quality compared to existing methods, and that the two-acquisition method is effective in resolving the relaxation effect during the adiabatic half passage.

  17. 3.0T MR imaging of the ankle: Axial traction for morphological cartilage evaluation, quantitative T2 mapping and cartilage diffusion imaging-A preliminary study.

    PubMed

    Jungmann, Pia M; Baum, Thomas; Schaeffeler, Christoph; Sauerschnig, Martin; Brucker, Peter U; Mann, Alexander; Ganter, Carl; Bieri, Oliver; Rummeny, Ernst J; Woertler, Klaus; Bauer, Jan S

    2015-08-01

    To determine the impact of axial traction during high resolution 3.0T MR imaging of the ankle on morphological assessment of articular cartilage and quantitative cartilage imaging parameters. MR images of n=25 asymptomatic ankles were acquired with and without axial traction (6kg). Coronal and sagittal T1-weighted (w) turbo spin echo (TSE) sequences with a driven equilibrium pulse and sagittal fat-saturated intermediate-w (IMfs) TSE sequences were acquired for morphological evaluation on a four-point scale (1=best, 4=worst). For quantitative assessment of cartilage degradation segmentation was performed on 2D multislice-multiecho (MSME) SE T2, steady-state free-precession (SSFP; n=8) T2 and SSFP diffusion-weighted imaging (DWI; n=8) images. Wilcoxon-tests and paired t-tests were used for statistical analysis. With axial traction, joint space width increased significantly and delineation of cartilage surfaces was rated superior (P<0.05). Cartilage surfaces were best visualized on coronal T1-w images (P<0.05). Differences for cartilage matrix evaluation were smaller. Subchondral bone evaluation, motion artifacts and image quality were not significantly different between the acquisition methods (P>0.05). T2 values were lower at the tibia than at the talus (P<0.001). Reproducibility was better for images with axial traction. Axial traction increased the joint space width, allowed for better visualization of cartilage surfaces and improved compartment discrimination and reproducibility of quantitative cartilage parameters. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Discrimination of benign and malignant lymph nodes at 7.0T compared to 1.5T magnetic resonance imaging using ultrasmall particles of iron oxide: a feasibility preclinical study.

    PubMed

    Kinner, Sonja; Maderwald, Stefan; Albert, Juliane; Parohl, Nina; Corot, Claire; Robert, Philippe; Baba, Hideo A; Barkhausen, Jörg

    2013-12-01

    To investigate the feasibility and performance of 7T magnetic resonance imaging compared to 1.5T imaging to discriminate benign (normal and inflammatory changed) from tumor-bearing lymph nodes in rabbits using ultrasmall particles of iron oxide (USPIO)-based contrast agents. Six New Zealand White rabbits were inoculated with either complete Freund's adjuvant cell suspension (n = 3) to induce reactively enlarged lymph nodes or with VX2 tumor cells to produce metastatic lymph nodes (n = 3). Image acquisition was performed before and 24 hours after bolus injection of an USPIO contrast agent at 1.5T and afterward at 7T using T1-weighted and T2*-weighted sequences. Sensitivities, specificities, and negative and positive predictive values for the detection of lymph node metastases were calculated for both field strengths with histopathology serving as reference standard. Sizes of lymph nodes with no, inflammatory, and malignant changes were compared using a Mann-Whitney U-test. All 24 lymph nodes were detected at 1.5T as well as at 7T. At 1.5T, sensitivity amounted to 0.67, while specificity reached a value of 1. At the higher field strength (7T), imaging was able to reach sensitivity and specificity values of 1. No statistical differences were detected concerning lymph node sizes. Magnetic resonance lymphography with USPIO contrast agents allows for differentiation of normal and reactively enlarged lymph nodes compared to metastatic nodes. First experiments at 7T show promising results compared to 1.5T, which have to be evaluated in further trials. Copyright © 2013. Published by Elsevier Inc.

  19. 7T MRI in focal epilepsy with unrevealing conventional field strength imaging.

    PubMed

    De Ciantis, Alessio; Barba, Carmen; Tassi, Laura; Cosottini, Mirco; Tosetti, Michela; Costagli, Mauro; Bramerio, Manuela; Bartolini, Emanuele; Biagi, Laura; Cossu, Massimo; Pelliccia, Veronica; Symms, Mark R; Guerrini, Renzo

    2016-03-01

    To assess the diagnostic yield of 7T magnetic resonance imaging (MRI) in detecting and characterizing structural lesions in patients with intractable focal epilepsy and unrevealing conventional (1.5 or 3T) MRI. We conducted an observational clinical imaging study on 21 patients (17 adults and 4 children) with intractable focal epilepsy, exhibiting clinical and electroencephalographic features consistent with a single seizure-onset zone (SOZ) and unrevealing conventional MRI. Patients were enrolled at two tertiary epilepsy surgery centers and imaged at 7T, including whole brain (three-dimensional [3D] T1 -weighted [T1W] fast-spoiled gradient echo (FSPGR), 3D susceptibility-weighted angiography [SWAN], 3D fluid-attenuated inversion recovery [FLAIR]) and targeted imaging (2D T2*-weighted dual-echo gradient-recalled echo [GRE] and 2D gray-white matter tissue border enhancement [TBE] fast spin echo inversion recovery [FSE-IR]). MRI studies at 1.5 or 3T deemed unrevealing at the referral center were reviewed by three experts in epilepsy imaging. Reviewers were provided information regarding the suspected localization of the SOZ. The same team subsequently reviewed 7T images. Agreement in imaging interpretation was reached through consensus-based discussions based on visual identification of structural abnormalities and their likely correlation with clinical and electrographic data. 7T MRI revealed structural lesions in 6 (29%) of 21 patients. The diagnostic gain in detection was obtained using GRE and FLAIR images. Four of the six patients with abnormal 7T underwent epilepsy surgery. Histopathology revealed focal cortical dysplasia (FCD) in all. In the remaining 15 patients (71%), 7T MRI remained unrevealing; 4 of the patients underwent epilepsy surgery and histopathologic evaluation revealed gliosis. 7T MRI improves detection of epileptogenic FCD that is not visible at conventional field strengths. A dedicated protocol including whole brain FLAIR and GRE images at 7T

  20. A pediatric brain structure atlas from T1-weighted MR images

    NASA Astrophysics Data System (ADS)

    Shan, Zuyao Y.; Parra, Carlos; Ji, Qing; Ogg, Robert J.; Zhang, Yong; Laningham, Fred H.; Reddick, Wilburn E.

    2006-03-01

    In this paper, we have developed a digital atlas of the pediatric human brain. Human brain atlases, used to visualize spatially complex structures of the brain, are indispensable tools in model-based segmentation and quantitative analysis of brain structures. However, adult brain atlases do not adequately represent the normal maturational patterns of the pediatric brain, and the use of an adult model in pediatric studies may introduce substantial bias. Therefore, we proposed to develop a digital atlas of the pediatric human brain in this study. The atlas was constructed from T1 weighted MR data set of a 9 year old, right-handed girl. Furthermore, we extracted and simplified boundary surfaces of 25 manually defined brain structures (cortical and subcortical) based on surface curvature. Higher curvature surfaces were simplified with more reference points; lower curvature surfaces, with fewer. We constructed a 3D triangular mesh model for each structure by triangulation of the structure's reference points. Kappa statistics (cortical, 0.97; subcortical, 0.91) indicated substantial similarities between the mesh-defined and the original volumes. Our brain atlas and structural mesh models (www.stjude.org/BrainAtlas) can be used to plan treatment, to conduct knowledge and modeldriven segmentation, and to analyze the shapes of brain structures in pediatric patients.

  1. Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

    PubMed

    Srichai, Monvadi B; Lim, Ruth P; Lath, Narayan; Babb, James; Axel, Leon; Kim, Daniel

    2013-01-01

    We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (<30 days) troponin elevation greater than 2 times the upper limit of normal as the reference standard for acute myocardial injury. Of the 65 patients, there were 21 (32%) with acute myocardial injury. Image quality and artifact scores were significantly better with FSE-SPAIR compared with FSE-STIR (2.15 vs 2.68, P < 0.01; 2.62 vs 3.05, P < 0.01, respectively). The sensitivity, specificity, positive predictive value, and negative predictive value for acute myocardial injury were as follows: 29%, 93%, 67%, and 73% for FSE-SPAIR; 38%, 91%, 67%, and 75% for FSE-STIR; 71%, 98%, 94%, and 88% for clinical interpretation including LGE, T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence

  2. Facile preparation of multifunctional uniform magnetic microspheres for T1-T2 dual modal magnetic resonance and optical imaging.

    PubMed

    Zhang, Li; Liang, Shuang; Liu, Ruiqing; Yuan, Tianmeng; Zhang, Shulai; Xu, Zushun; Xu, Haibo

    2016-08-01

    Molecular imaging is of significant importance for early detection and diagnosis of cancer. Herein, a novel core-shell magnetic microsphere for dual modal magnetic resonance imaging (MRI) and optical imaging was produced by one-pot emulsifier-free emulsion polymerization, which could provide high resolution rate of histologic structure information and realize high sensitive detection at the same time. The synthesized magnetic microspheres composed of cores containing oleic acid (OA) and sodium undecylenate (NaUA) modified Fe3O4 nanoparticles and styrene (St), Glycidyl methacrylate (GMA), and polymerizable lanthanide complexes (Gd(AA)3Phen and Eu(AA)3Phen) polymerized on the surface for outer shells. Fluorescence spectra show characteristic emission peaks from Eu(3+) at 590nm and 615nm and vivid red fluorescence luminescence can be observed by 2-photon confocal scanning laser microscopy (CLSM). In vitro cytotoxicity tests based on the MTT assay demonstrate good cytocompatibility, the composites have longitudinal relaxivity value (r1) of 8.39mM(-1)s(-1) and also have transverse relaxivity value (r2) of 71.18mM(-1)s(-1) at clinical 3.0 T MR scanner. In vitro and in vivo MRI studies exhibit high signal enhancement on both T1- and T2-weighted MR images. These fascinating multifunctional properties suggest that the polymer microspheres have large clinical potential as multi-modal MRI/optical probes. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  3. ``Smart'' theranostic lanthanide nanoprobes with simultaneous up-conversion fluorescence and tunable T1-T2 magnetic resonance imaging contrast and near-infrared activated photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Das, Gautom Kumar; Vijayaragavan, Vimalan; Xu, Qing Chi; Padmanabhan, Parasuraman; Bhakoo, Kishore K.; Tamil Selvan, Subramanian; Tan, Timothy Thatt Yang

    2014-10-01

    The current work reports a type of ``smart'' lanthanide-based theranostic nanoprobe, NaDyF4:Yb3+/NaGdF4:Yb3+,Er3+, which is able to circumvent the up-converting poisoning effect of Dy3+ ions to give efficient near infrared (980 nm) triggered up-conversion fluorescence, and offers not only excellent dark T2-weighted MR contrast but also tunable bright and T1-weighted MR contrast properties. Due to the efficient up-converted energy transfer from the nanocrystals to chlorin e6 (Ce6) photosensitizers loaded onto the nanocrystals, cytotoxic singlet oxygen was generated and photodynamic therapy was demonstrated. Therefore, the current multifunctional nanocrystals could be potentially useful in various image-guided diagnoses where bright or dark MRI contrast could be selectively tuned to optimize image quality, but also as an efficient and more penetrative near-infrared activated photodynamic therapy agent.The current work reports a type of ``smart'' lanthanide-based theranostic nanoprobe, NaDyF4:Yb3+/NaGdF4:Yb3+,Er3+, which is able to circumvent the up-converting poisoning effect of Dy3+ ions to give efficient near infrared (980 nm) triggered up-conversion fluorescence, and offers not only excellent dark T2-weighted MR contrast but also tunable bright and T1-weighted MR contrast properties. Due to the efficient up-converted energy transfer from the nanocrystals to chlorin e6 (Ce6) photosensitizers loaded onto the nanocrystals, cytotoxic singlet oxygen was generated and photodynamic therapy was demonstrated. Therefore, the current multifunctional nanocrystals could be potentially useful in various image-guided diagnoses where bright or dark MRI contrast could be selectively tuned to optimize image quality, but also as an efficient and more penetrative near-infrared activated photodynamic therapy agent. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr01717j

  4. Utility of diffusion-weighted MR imaging in the diagnosis of placenta accreta spectrum abnormality.

    PubMed

    Sannananja, Bhagya; Ellermeier, Anna; Hippe, Daniel S; Winter, Thomas C; Kang, Stella K; Lee, Susanna I; Kilgore, Mark R; Dighe, Manjiri K

    2018-04-17

    The aim of this study was to evaluate the utility of added DWI sequences as an adjunct to traditional MR imaging in the evaluation of abnormal placentation in patients with suspicion for placenta accreta spectrum abnormality or morbidly adherent placenta (MAP). The study was approved by local ethics committee. The subjects included pregnant women with prenatal MRI performed between July 2013 to July 2015. All imaging was performed on a Philips 1.5T MR scanner using pelvic phased-array coil. Only T2-weighted and diffusion-weighted imaging (DWI) series were compiled for review. Two randomized imaging sets were created: set 1 included T2-weighted series only (T2W); set 2 included T2W with DWI series together (T2W + DWI). Three radiologists, blinded to history and pathology, reviewed the imaging, with 2 weeks of time between the two image sets. Sensitivity, specificity, and overall accuracy for MAP were calculated and compared between T2W only and T2W + DWI reads. Associations between imaging findings and invasion on pathology were tested using the Chi-squared test. Confidence scores, inter-reader agreement, and systematic differences were documented. A total of 17 pregnant women were included in the study. 8 cases were pathologically diagnosed with MAP. There were no significant differences in the diagnostic accuracy between T2W and T2W + DWI in the diagnosis of MAP in terms of overall accuracy (62.7% for T2W vs. 68.6% for T2W + DWI, p = 0.68), sensitivity (70.8% for T2W vs. 95.8% for T2W + DWI, p = 0.12), and specificity (55.6% for T2W vs. 44.4% for T2W + DWI, p = 0.49). There was no significant difference in the diagnostic confidence between the review of T2W images alone and the T2W + DWI review (mean 7.3 ± 1.8 for T2W vs. 7.5 ± 1.8 for T2W + DWI, p = 0.37). With the current imaging technique, addition of DWI sequence to the traditional T2W images cannot be shown to significantly increase the accuracy or

  5. Intensity-based dual model method for generation of synthetic CT images from standard T2-weighted MR images - Generalized technique for four different MR scanners.

    PubMed

    Koivula, Lauri; Kapanen, Mika; Seppälä, Tiina; Collan, Juhani; Dowling, Jason A; Greer, Peter B; Gustafsson, Christian; Gunnlaugsson, Adalsteinn; Olsson, Lars E; Wee, Leonard; Korhonen, Juha

    2017-12-01

    Recent studies have shown that it is possible to conduct entire radiotherapy treatment planning (RTP) workflow using only MR images. This study aims to develop a generalized intensity-based method to generate synthetic CT (sCT) images from standard T2-weighted (T2 w ) MR images of the pelvis. This study developed a generalized dual model HU conversion method to convert standard T2 w MR image intensity values to synthetic HU values, separately inside and outside of atlas-segmented bone volume contour. The method was developed and evaluated with 20 and 35 prostate cancer patients, respectively. MR images with scanning sequences in clinical use were acquired with four different MR scanners of three vendors. For the generated synthetic CT (sCT) images of the 35 prostate patients, the mean (and maximal) HU differences in soft and bony tissue volumes were 16 ± 6 HUs (34 HUs) and -46 ± 56 HUs (181 HUs), respectively, against the true CT images. The average of the PTV mean dose difference in sCTs compared to those in true CTs was -0.6 ± 0.4% (-1.3%). The study provides a generalized method for sCT creation from standard T2 w images of the pelvis. The method produced clinically acceptable dose calculation results for all the included scanners and MR sequences. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. SU-E-J-217: Multiparametric MR Imaging of Cranial Tumors On a Dedicated 1.0T MR Simulator Prior to Stereotactic Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wen, N; Glide-Hurst, C; Liu, M

    Purpose: Quantitative magnetic resonance imaging (MRI) of cranial lesions prior to stereotactic radiosurgery (SRS) may improve treatment planning and provide potential prognostic value. The practicality and logistics of acquiring advanced multiparametric MRI sequences to measure vascular and cellular properties of cerebral tumors are explored on a 1.0 Tesla MR Simulator. Methods: MR simulation was performed immediately following routine CT simulation on a 1T MR Simulator. MR sequences used were in the order they were performed: T2-Weighted Turbo Spin Echo (T2W-TSE), T2 FLAIR, Diffusion-weighted (DWI, b = 0, 800 to generate an apparent diffusion coefficient (ADC) map), 3D T1-Weighted Fast Fieldmore » Echo (T1W-FFE), Dynamic Contrast Enhanced (DCE) and Post Gadolinium Contrast Enhanced 3D T1W-FFE images. T1 pre-contrast values was generated by acquiring six different flip angles. The arterial input function was derived from arterial pixels in the perfusion images selected manually. The extended Tofts model was used to generate the permeability maps. Routine MRI scans took about 30 minutes to complete; the additional scans added 12 minutes. Results: To date, seven patients with cerebral tumors have been imaged and tumor physiology characterized. For example, on a glioblastoma patient, the volume contoured on T1 Gd images, ADC map and the pharmacokinetic map (Ktrans) were 1.9, 1.4, and 1.5 cc respectively with strong spatial correlation. The mean ADC value of the entire volume was 1141 μm2/s while the value in the white matter was 811 μm2/s. The mean value of Ktrans was 0.02 min-1 in the tumor volume and 0.00 in the normal white matter. Conclusion: Our initial results suggest that multiparametric MRI sequences may provide a more quantitative evaluation of vascular and tumor properties. Implementing functional imaging during MR-SIM may be particularly beneficial in assessing tumor extent, differentiating radiation necrosis from tumor recurrence, and establishing

  7. T1-T2 dual-modal MRI of brain gliomas using PEGylated Gd-doped iron oxide nanoparticles.

    PubMed

    Xiao, Ning; Gu, Wei; Wang, Hao; Deng, Yunlong; Shi, Xin; Ye, Ling

    2014-03-01

    To overcome the negative contrast limitations of iron oxide-based contrast agents and to improve the biocompatibility of Gd-chelate contrast agents, PEGylated Gd-doped iron oxide (PEG-GdIO) NPs as a T1-T2 dual-modal contrast agent were synthesized by the polyol method. The transverse relaxivity (r2) and longitudinal relaxivity (r1) of PEG-GdIO were determined to be 66.9 and 65.9 mM(-1) s(-1), respectively. The high r1 value and low r2/r1 ratio make PEG-GdIO NPs suitable as a T1-T2 dual-modal contrast agent. The in vivo MRI demonstrated a brighter contrast enhancement in T1-weighted image and a simultaneous darken effect in T2-weighted MR image compared to the pre-contrast image in the region of glioma. Furthermore, the biocompatibility of PEG-GdIO NPs was confirmed by the in vitro MTT cytotoxicity and in vivo histological analyses (H&E). Therefore, PEG-GdIO NPs hold great potential in T1-T2 dual-modal imaging for the diagnosis of brain glioma. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. [Carotid plaque assessment using inversion recovery T1 weighted-3 dimensions variable refocus flip angle turbo spin echo sampling perfection with application optimized contrast using different angle evolutions black blood imaging].

    PubMed

    Inoue, Yuji; Yoneyama, Masami; Nakamura, Masanobu; Ozaki, Satoshi; Ito, Kenjiro; Hiura, Mikio

    2012-01-01

    Vulnerable plaque can be attributed to induction of ischemic symptoms and magnetic resonance imaging of carotid artery is valuable to detect the plaque. Magnetization prepared rapid acquisition with gradient echo (MPRAGE) method could detect hemorrhagic vulnerable plaque as high intensity signal; however, blood flow is not sufficiently masked by this method. The contrast for plaque in T1 weighted image (T1WI) could not be obtained sufficiently with black blood image (BBI) by sampling perfection with application optimized contrast using different angle evolutions (SPACE) method as turbo spin echo (TSE). In addition, an appearance of artifact by slow flow is a problem. Considering these controversial situations in plaque imaging, we examined the modified BBI inversion recovery (IR)-SPACE in which IR was added for SPACE method so that the contrast for plaque in T1WI was optimized. We investigated the application of this method in plaque imaging. As a result of phantom imaging, the contrast for plaque in T1WI was definitely obtained by choosing an appropriate inversion time (TI) for the corresponding repetition time. In clinical cases, blood flow was sufficiently masked by IR-SPACE method and the plaque imaging was clearly obtained in clinical cases to the same extent as MPRAGE method. Since BBI with IR-SPACE method was derived from both IR pulse and flow void effect, this method could obtain the blood flow masking effect definitely. The present study suggested that SPACE method might be applicable to estimate properties of carotid artery plaque.

  9. Fully automatic detection of deep white matter T1 hypointense lesions in multiple sclerosis

    NASA Astrophysics Data System (ADS)

    Spies, Lothar; Tewes, Anja; Suppa, Per; Opfer, Roland; Buchert, Ralph; Winkler, Gerhard; Raji, Alaleh

    2013-12-01

    A novel method is presented for fully automatic detection of candidate white matter (WM) T1 hypointense lesions in three-dimensional high-resolution T1-weighted magnetic resonance (MR) images. By definition, T1 hypointense lesions have similar intensity as gray matter (GM) and thus appear darker than surrounding normal WM in T1-weighted images. The novel method uses a standard classification algorithm to partition T1-weighted images into GM, WM and cerebrospinal fluid (CSF). As a consequence, T1 hypointense lesions are assigned an increased GM probability by the standard classification algorithm. The GM component image of a patient is then tested voxel-by-voxel against GM component images of a normative database of healthy individuals. Clusters (≥0.1 ml) of significantly increased GM density within a predefined mask of deep WM are defined as lesions. The performance of the algorithm was assessed on voxel level by a simulation study. A maximum dice similarity coefficient of 60% was found for a typical T1 lesion pattern with contrasts ranging from WM to cortical GM, indicating substantial agreement between ground truth and automatic detection. Retrospective application to 10 patients with multiple sclerosis demonstrated that 93 out of 96 T1 hypointense lesions were detected. On average 3.6 false positive T1 hypointense lesions per patient were found. The novel method is promising to support the detection of hypointense lesions in T1-weighted images which warrants further evaluation in larger patient samples.

  10. Functional magnetic porous silica for T 1-T 2 dual-modal magnetic resonance imaging and pH-responsive drug delivery of basic drugs

    NASA Astrophysics Data System (ADS)

    Li, Ling; Zhang, Run; Guo, Yi; Zhang, Cheng; Zhao, Wei; Xu, Zhiping; Whittaker, Andrew K.

    2016-12-01

    A smart magnetic-targeting drug carrier γ-Fe2O3@p-silica comprising a γ-Fe2O3 core and porous shell has been prepared and characterized. The particles have a uniform size of about 60 nm, and a porous shell of thickness 3 nm. Abundant hydroxyl groups and a large surface area enabled the γ-Fe2O3@p-silica to be readily loaded with a large payload of the basic model drug rhodamine B (RB) (up to 73 mg g-1). Cytotoxicity assays of the γ-Fe2O3@p-silica particles indicated that the particles were biocompatible and suitable for carrying drugs. It was found that the RB was released rapidly at pH 5.5 but at pH 7.4 the rate and extent of release was greatly attenuated. The particles therefore demonstrate an excellent pH-triggered drug release. In addition, the γ-Fe2O3@p-silica particles could be tracked by magnetic resonance imaging (MRI). A clear dose-dependent contrast enhancement in both T 1-weighted and T 2-weighted MR images indicated the potential of the γ-Fe2O3@p-silica particles to act as dual-mode T 1 and T 2 MRI contrast agents.

  11. WE-G-BRD-09: Prediction of Local Control/Failure by Using Feature Histogram Selection in Follow-Up T2-Weighted MR Image in Spinal Tumors After Stereotactic Body Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, J; Harb, J; Jawad, M

    2014-06-15

    Purpose: In follow-up T2-weighted MR images of spinal tumor patients treated with stereotactic body radiation therapy (SBRT), high intensity features embedded in dark surroundings may suggest a local failure (LF). We investigated image intensity histogram in imaging features to predict LF and local control (LC). Methods: Sixty-seven spinal tumors were treated with SBRT at our institution with scheduled follow-up MR T2-weighted (TR 3200–6600ms; TE 75-132ms) imaging. The LF group included 10 tumors with 8.7 months median follow-up, while the LC group had 11 tumors with 24.1 months median follow-up. The follow-up images were fused to the planning CT. Image intensitymore » histograms of the GTV were calculated. Voxels in greater than 90% (V90), 80% (V80), and peak (Vpeak) of the histogram were grouped into sub-ROIs to determine the best feature histogram. The intensity of each sub-ROI was evaluated using the mean T2-weighted signal ratio (intensity in sub-ROI / intensity in normal vertebrae). An ROC curve in predicting LF for each sub-ROI was calculated to determine the best feature histogram parameter for LF prediction. Results: Mean T2-weighted signal ratio in the LF group was significantly higher than that in the LC group for all sub-ROIs (1.1±0.4 vs. 0.7±0.2, 1.2±0.4 vs. 0.8±0.2, 1.4±0.5 vs. 0.8±0.2, for V90, V80, and Vpeak, p=0.02, 0.02, and 0.002, respectively). The corresponding areas-under-curve (AUC) of ROC were 0.78, 0.80, and 0.87, p=0.02, 0.03, 0.004, respectively. No correlation was found between T2-weighted signal ratio in Vpeak and follow-up time (Pearson's ρ=0.15). Conclusion: Increased T2-weighted signal can be used to identify local failure while decreased signal indicates local control after spinal SBRT. By choosing the best histogram parameter (here the Vpeak), the AUC of the ROC can be substantially improved, which implies reliable prediction of LC and LF. These results are being further studied and validated with large multi

  12. Effect of low refocusing angle in T1-weighted spin echo and fast spin echo MRI on low-contrast detectability: a comparative phantom study at 1.5 and 3 Tesla.

    PubMed

    Sarkar, Subhendra N; Mangosing, Jason L; Sarkar, Pooja R

    2013-01-01

    MRI tissue contrast is not well preserved at high field. In this work, we used a phantom with known, intrinsic contrast (3.6%) for model tissue pairs to test the effects of low angle refocusing pulses and magnetization transfer from adjacent slices on intrinsic contrast at 1.5 and 3 Tesla. Only T1-weighted spin echo sequences were tested since for such sequences the contrast loss, tissue heating, and image quality degradation at high fields seem to present significant diagnostic and quality issues. We hypothesized that the sources of contrast loss could be attributed to low refocusing angles that do not fulfill the Hahn spin echo conditions or to magnetization transfer effects from adjacent slices in multislice imaging. At 1.5 T the measured contrast was 3.6% for 180° refocusing pulses and 2% for 120° pulses, while at 3 T, it was 4% for 180° and only 1% for 120° refocusing pulses. There was no significant difference between single slice and multislice imaging suggesting little or no role played by magnetization transfer in the phantom chosen. Hence, one may conclude that low angle refocusing pulses not fulfilling the Hahn spin echo conditions are primarily responsible for significant deterioration of T1-weighted spin echo image contrast in high-field MRI.

  13. Distortion correction of echo-planar diffusion-weighted images of uterine cervix.

    PubMed

    deSouza, Nandita M; Orton, Matthew; Downey, Kate; Morgan, Veronica A; Collins, David J; Giles, Sharon L; Payne, Geoffrey S

    2016-05-01

    To investigate the clinical utility of the reverse gradient algorithm in correcting distortions in diffusion-weighted images of the cervix and for increasing diagnostic performance. Forty-one patients ages 25-72 years (mean 40 ± 11 years) with suspected or early stage cervical cancer were imaged at 3T using an endovaginal coil. T2 -weighted (W) and diffusion-weighted images with right and left phase-encode gradient directions were obtained coronal to the cervix (b = 0, 100, 300, 500, 800 s mm(-2) ). Differences in angle of the endocervical canal to the x-axis between T2 W and right-gradient, left-gradient, and corrected images were measured. Uncorrected and corrected images were assessed for diagnostic performance when viewed together with T2 W images by two independent observers against subsequent histology. The angles of the endocervical canal relative to the x-axis were significantly different between the T2 W images and the right-gradient images (P = 0.007), approached significance for left-gradient images (P = 0.055), and were not significantly different after correction (P = 0.95). Corrected images enabled a definitive diagnosis in 34% (n = 14) of patients classified as equivocal on uncorrected images. Tumor volume in this subset was 0.18 ± 0.44 cm(3) (mean ± SD; sensitivity of detection 100% [8/8], specificity 50% [3/6] for an experienced observer). Correction did not improve diagnostic performance for the less-experienced observer. Distortion-corrected diffusion-weighted images improved correspondence with T2 W images and diagnostic performance in a third of cases. © 2015 The Authors Journal of Magnetic Resonance Imaging published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  14. Evaluation of Renal Oxygenation Level Changes after Water Loading Using Susceptibility-Weighted Imaging and T2* Mapping.

    PubMed

    Ding, Jiule; Xing, Wei; Wu, Dongmei; Chen, Jie; Pan, Liang; Sun, Jun; Xing, Shijun; Dai, Yongming

    2015-01-01

    To assess the feasibility of susceptibility-weighted imaging (SWI) while monitoring changes in renal oxygenation level after water loading. Thirty-two volunteers (age, 28.0 ± 2.2 years) were enrolled in this study. SWI and multi-echo gradient echo sequence-based T2(*) mapping were used to cover the kidney before and after water loading. Cortical and medullary parameters were measured using small regions of interest, and their relative changes due to water loading were calculated based on baseline and post-water loading data. An intraclass correlation coefficient analysis was used to assess inter-observer reliability of each parameter. A receiver operating characteristic curve analysis was conducted to compare the performance of the two methods for detecting renal oxygenation changes due to water loading. Both medullary phase and medullary T2(*) values increased after water loading (p < 0.001), although poor correlations were found between the phase changes and the T2(*) changes (p > 0.05). Interobserver reliability was excellent for the T2(*) values, good for SWI cortical phase values, and moderate for the SWI medullary phase values. The area under receiver operating characteristic curve of the SWI medullary phase values was 0.85 and was not different from the medullary T2(*) value (0.84). Susceptibility-weighted imaging enabled monitoring changes in the oxygenation level in the medulla after water loading, and may allow comparable feasibility to detect renal oxygenation level changes due to water loading compared with that of T2(*) mapping.

  15. SU-E-J-224: Using UTE and T1 Weighted Spin Echo Pulse Sequences for MR-Only Treatment Planning; Phantom Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, H; Fatemi, A; Sahgal, A

    Purpose: Investigating a new approach in MRI based treatment planning using the combination of (Ultrashort Echo Time) UTE and T1 weighted spin echo pulse sequences to delineate air, bone and water (soft tissues) in generating pseudo CT images comparable with CT. Methods: A gel phantom containing chicken bones, ping pang balls filled with distilled water and air bubbles, was made. It scanned with MRI using UTE and 2D T1W SE pulse sequences with (in plane resolution= 0.53mm, slice thickness= 2 mm) and CT with (in plane resolution= 0.5 mm and slice thickness= 0.75mm) as a ground truth for geometrical accuracy.more » The UTE and T1W SE images were registered with CT using mutual information registration algorithm provided by Philips Pinnacle treatment planning system. The phantom boundaries were detected using Canny edge detection algorithm for CT, and MR images. The bone, air bubbles and water in ping pong balls were segmented from CT images using threshold 300HU, - 950HU and 0HU, respectively. These tissue inserts were automatically segmented from combined UTE and T1W SE images using edge detection and relative intensity histograms of the phantom. The obtained segmentations of air, bone and water inserts were evaluated with those obtained from CT. Results: Bone and air can be clearly differentiated in UTE images comparable to CT. Combining UTE and T1W SE images successfully segmented the air, bone and water. The maximum segmentation differences from combine MRI images (UTE and T1W SE) and CT are within 1.3 mm, 1.1mm for bone, air, respectively. The geometric distortion of UTE sequence is small less than 1 pixel (0.53 mm) of MR image resolution. Conclusion: Our approach indicates that MRI can be used solely for treatment planning and its quality is comparable with CT.« less

  16. Simultaneous dual contrast weighting using double echo rapid acquisition with relaxation enhancement (RARE) imaging.

    PubMed

    Fuchs, Katharina; Hezel, Fabian; Klix, Sabrina; Mekle, Ralf; Wuerfel, Jens; Niendorf, Thoralf

    2014-12-01

    This work proposes a dual contrast rapid acquisition with relaxation enhancement (RARE) variant (2in1-RARE), which provides simultaneous proton density (PD) and T2 * contrast in a single acquisition. The underlying concept of 2in1-RARE is the strict separation of spin echoes and stimulated echoes. This approach offers independent weighting of spin echoes and stimulated echoes. 2in1-RARE was evaluated in phantoms including signal-to-noise ratio (SNR) and point spread function assessment. 2in1-RARE was benchmarked versus coherent RARE and a split-echo RARE variant. The applicability of 2in1-RARE for brain imaging was demonstrated in a small cohort of healthy subjects (n = 10) and, exemplary, a multiple sclerosis patient at 3 Tesla as a precursor to a broader clinical study. 2in1-RARE enables the simultaneous acquisition of dual contrast weighted images without any significant image degradation and without sacrificing SNR versus split-echo RARE. This translates into a factor of two speed gain over multi-contrast, sequential split-echo RARE. A 15% broadening of the point spread function was observed in 2in1-RARE. T1 relaxation effects during the mixing time can be neglected for brain tissue. 2in1-RARE offers simultaneous acquisition of images of anatomical (PD) and functional (T2 *) contrast. It presents an alternative to address scan time constraints frequently encountered during sequential acquisition of T2 * or PD-weighted RARE. © 2013 Wiley Periodicals, Inc.

  17. High-resolution heavily T2-weighted magnetic resonance imaging for evaluation of the pituitary stalk in children with ectopic neurohypophysis.

    PubMed

    El Sanharawi, Imane; Tzarouchi, Loukia; Cardoen, Liesbeth; Martinerie, Laetitia; Leger, Juliane; Carel, Jean-Claude; Elmaleh-Berges, Monique; Alison, Marianne

    2017-05-01

    In anterior pituitary deficiency, patients with non visible pituitary stalk have more often multiple deficiencies and persistent deficiency than patients with visible pituitary stalk. To compare the diagnostic value of a high-resolution heavily T2-weighted sequence to 1.5-mm-thick unenhanced and contrast-enhanced sagittal T1-weighted sequences to assess the presence of the pituitary stalk in children with ectopic posterior pituitary gland. We retrospectively evaluated the MRI data of 14 children diagnosed with ectopic posterior pituitary gland between 2010 and 2014. We evaluated the presence of a pituitary stalk using a sagittal high-resolution heavily T2-weighted sequence and a 1.5-mm sagittal T1-weighted turbo spin-echo sequence before and after contrast medium administration. A pituitary stalk was present on at least one of the sequences in 10 of the 14 children (71%). T2-weighted sequence depicted the pituitary stalk in all 10 children, whereas the 1.5-mm-thick T1-weighted sequence depicted 2/10 (20%) before contrast injection and 8/10 (80%) after contrast injection (P=0.007). Compared with 1.5-mm-thick contrast-enhanced T1-weighted sequences, high-resolution heavily T2-weighted sequence demonstrates better sensitivity in detecting the pituitary stalk in children with ectopic posterior pituitary gland, suggesting that contrast injection is unnecessary to assess the presence of a pituitary stalk in this setting.

  18. Detection of the index tumour and tumour volume in prostate cancer using T2-weighted and diffusion-weighted magnetic resonance imaging (MRI) alone.

    PubMed

    Rud, Erik; Klotz, Dagmar; Rennesund, Kristin; Baco, Eduard; Berge, Viktor; Lien, Diep; Svindland, Aud; Lundeby, Eskild; Berg, Rolf E; Eri, Lars M; Eggesbø, Heidi B

    2014-12-01

    To examine the performance of T2-weighted (T2W) and diffusion-weighted (DW) magnetic resonance imaging (MRI) for detecting the index tumour in patients with prostate cancer and to examine the agreement between MRI and histology when assessing tumour volume (TV) and overall tumour burden. The study included 199 consecutive patients with biopsy confirmed prostate cancer randomised to MRI before radical prostatectomy from December 2009 to July 2012. MRI-detected tumours (MRTs) were ranked from 1 to 3 according to decreasing volume and were compared with histologically detected tumours (HTs) ranked from 1 to 3, with HT 1 = index tumour. Whole-mount section histology was used as a reference standard. The TVs of true-positive MRTs (MRTVs 1-3) were compared with the TVs found by histology (HTVs 1-3). All tumours were registered on a 30-sector map and by classifying each sector as positive/negative, the rate of true-positive and -negative sectors was calculated. The detection rate for the HT 1 (index tumour) was 92%; HT 2, 45%; and HT 3, 37%. The MRTV 1-3 vs the HTV 1-3 were 2.8 mL vs 4.0 mL (index tumour, P < 0.001), 1.0 mL vs 0.9 mL (tumour 2, P = 0.413), and 0.6 mL vs 0.5 mL (tumour 3, P = 0.492). The rate of true-positive and -negative sectors was 50% and 88%, κ = 0.39. A combination of T2W and DW MRI detects the index tumour in 92% of cases, although MRI underestimates both TV and tumour burden compared with histology. © 2014 The Authors. BJU International © 2014 BJU International.

  19. Sensitivity and specificity of unenhanced MR mammography (DWI combined with T2-weighted TSE imaging, ueMRM) for the differentiation of mass lesions.

    PubMed

    Baltzer, Pascal A T; Benndorf, Matthias; Dietzel, Matthias; Gajda, Mieczyslaw; Camara, Oumar; Kaiser, Werner A

    2010-05-01

    This study was performed to assess the sensitivity and specificity for malignant and benign mass lesions of a diagnostic approach combining DWI with T2-weighted images (unenhanced MR mammography, ueMRM) and compare the results with contrast-enhanced MR mammography (ceMRM). Consecutive patients undergoing histopathological verification of mass lesions after MR mammography without prior breast interventions (contrast-enhanced T1-weighted, T2-weighted and DWI sequences) were eligible for this retrospective investigation. Two blinded observers first rated ueMRM and then ceMRM according to the BIRADS scale. Lesion size, ADC values and T2-weighted TSE descriptors were assessed. This study examined 81 lesions (27 benign, 54 malignant). Sensitivity of ueMRM was 93% (observer 1) and 86% (observer 2), respectively. Sensitivity of ceMRM was 96.5% (observer 1) and 98.3% (observer 2). Specificity was 85.2% (ueMRM) and 92.6% (ceMRM) for both observers. The differences between both methods and observers were not significant (P > or = 0.09). Lesion size measurements did not differ significantly among all sequences analyzed. Tumor visibility was worse using ueMRM for both benign (P < 0.001) and malignant lesions (P = 0.004). Sensitivity and specificity of ueMRM in mass lesions equal that of ceMRM. However, a reduced lesion visibility in ueMRM may lead to more false-negative findings.

  20. Simultaneous Measurement of T2 and Apparent Diffusion Coefficient (T2+ADC) in the Heart With Motion-Compensated Spin Echo Diffusion-Weighted Imaging

    PubMed Central

    Aliotta, Eric; Moulin, Kévin; Zhang, Zhaohuan; Ennis, Daniel B.

    2018-01-01

    Purpose To evaluate a technique for simultaneous quantitative T2 and apparent diffusion coefficient (ADC) mapping in the heart (T2+ADC) using spin echo (SE) diffusion-weighted imaging (DWI). Theory and Methods T2 maps from T2+ADC were compared with single-echo SE in phantoms and with T2-prepared (T2-prep) balanced steady-state free precession (bSSFP) in healthy volunteers. ADC maps from T2+ADC were compared with conventional DWI in phantoms and in vivo. T2+ADC was also demonstrated in a patient with acute myocardial infarction (MI). Results Phantom T2 values from T2+ADC were closer to a single-echo SE reference than T2-prep bSSFP (−2.3 ± 6.0% vs 22.2 ± 16.3%; P < 0.01), and ADC values were in excellent agreement with DWI (0.28 ± 0.4%). In volunteers, myocardial T2 values from T2+ADC were significantly shorter than T2-prep bSSFP (35.8 ± 3.1 vs 46.8 ± 3.8 ms; P < 0.01); myocardial ADC was not significantly (N.S.) different between T2+ADC and conventional motion-compensated DWI (1.39 ± 0.18 vs 1.38 ± 0.18 mm2/ms; P = N.S.). In the patient, T2 and ADC were both significantly elevated in the infarct compared with remote myocardium (T2: 40.4 ± 7.6 vs 56.8 ± 22.0; P < 0.01; ADC: 1.47 ± 0.59 vs 1.65 ± 0.65 mm2/ms; P < 0.01). Conclusion T2+ADC generated coregistered, free-breathing T2 and ADC maps in healthy volunteers and a patient with acute MI with no cost in accuracy, precision, or scan time compared with DWI. PMID:28516485

  1. Pitfalls of diffusion-weighted imaging of the female pelvis

    PubMed Central

    Duarte, Ana Luisa; Dias, João Lopes; Cunha, Teresa Margarida

    2018-01-01

    Diffusion-weighted imaging (DWI) is widely used in protocols for magnetic resonance imaging (MRI) of the female pelvis. It provides functional and structural information about biological tissues, without the use of ionizing radiation or intravenous administration of contrast medium. High signal intensity on DWI with simultaneous low signal intensity on apparent diffusion coefficient maps is usually associated with malignancy. However, that pattern can also be seen in many benign lesions, a fact that should be recognized by radiologists. Correlating DWI findings with those of conventional (T1- and T2-weighted) MRI sequences and those of contrast-enhanced MRI sequences is mandatory in order to avoid potential pitfalls. The aim of this review article is the description of the most relevant physiological and benign pathological conditions of the female pelvis that can show restricted diffusion on DWI. PMID:29559764

  2. Singleshot T1 Mapping using Simultaneous Acquisitions of Spin- and STimulated-Echo Planar Imaging (2D ss-SESTEPI)

    PubMed Central

    Shi, Xianfeng; Kim, Seong-Eun; Jeong, Eun-Kee

    2011-01-01

    The conventional stimulated-echo NMR sequence only measures the longitudinal component, while discarding the transverse component, after tipping up the prepared magnetization. This transverse magnetization can be used to measure a spin-echo, in addition to the stimulated-echo. 2D ss-SESTEPI is an EPI-based singleshot imaging technique that simultaneously acquires a spin-echo-planar image (SEPI) and a stimulated-echo-planar image (STEPI) after a single RF excitation. The magnitudes of SEPI and STEPI differ by T1 decay and diffusion weighting for perfect 90° RF, and thus can be used to rapidly measure T1. However, the spatial variation of B1 amplitude induces un-even splitting of the transverse magnetization for SEPI and STEPI within the imaging FOV. Correction for B1 inhomogeneity is therefore critical for 2D ss-SESTEPI to be used for T1 measurement. We developed a method for B1 inhomogeneity correction by acquiring an additional STEPI with minimal mixing time, calculating the difference between the spin-echo and the stimulated-echo and multiplying the STEPI by the inverse functional map. Diffusion-induced decay is corrected by measuring the average diffusivity during the prescanning. Rapid singleshot T1 mapping may be useful for various applications, such as dynamic T1 mapping for real-time estimation of the concentration of contrast agent in DCE-MRI. PMID:20564579

  3. MR-Guided Freehand Biopsy of Liver Lesions With Fast Continuous Imaging Using a 1.0-T Open MRI Scanner: Experience in 50 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischbach, Frank, E-mail: frank.fischbach@med.ovgu.de; Bunke, Juergen; Thormann, Markus

    2011-02-15

    The purpose of this study was to assess a new open system with a field-strength of 1.0 T for the feasibility of liver biopsy using the freehand technique with fast continuous imaging. Fifty patients with focal liver lesions measuring 5 to 30 mm in diameter were included in the study. Guidance and monitoring was performed using a 1.0-T open magnetic resonance (MR) scanner (Panorama HFO; Philips Healthcare, Best, The Netherlands). With fast continuous imaging using a T1-weighted (T1W) gradient echo (GRE) sequence after administration of gadolinium (Gd)-EOB-DTPA, the needle was placed into the lesion. An interface for interactive dynamic viewingmore » in two perpendicular planes prevented needle deviations T2-weighted turbo spin echo (TSE) fat-suppressed sequence was added to rule out postinterventional hematoma or biloma. All lesions were visible on the interventional images. Biopsy was technically successful, and solid specimens were obtained in all cases. Forty-six patients showed a histopathologic pattern other than native liver tissue, thus confirming correct position of the needle. Time between determination of the lesion and performance of the control scan was on average 18 min. No major complications were recorded. MR guidance with the new 1-T open system must be considered an attractive alternative for liver punction. An interface for dynamic imaging of needle guidance and T1W-GRE imaging with administration of Gd-EOB-DTPA for contrast enhancement allows the pinpoint puncture of liver lesions.« less

  4. Comparison of Diffusion-Weighted Imaging in the Human Brain Using Readout-Segmented EPI and PROPELLER Turbo Spin Echo With Single-Shot EPI at 7 T MRI.

    PubMed

    Kida, Ikuhiro; Ueguchi, Takashi; Matsuoka, Yuichiro; Zhou, Kun; Stemmer, Alto; Porter, David

    2016-07-01

    The purpose of the present study was to compare periodically rotated overlapping parallel lines with enhanced reconstruction-type turbo spin echo diffusion-weighted imaging (pTSE-DWI) and readout-segmented echo planar imaging (rsEPI-DWI) with single-shot echo planar imaging (ssEPI-DWI) in a 7 T human MR system. We evaluated the signal-to-noise ratio (SNR), image distortion, and apparent diffusion coefficient values in the human brain. Six healthy volunteers were included in this study. The study protocol was approved by our institutional review board. All measurements were performed at 7 T using pTSE-DWI, rsEPI-DWI, and ssEPI-DWI sequences. The spatial resolution was 1.2 × 1.2 mm in-plane with a 3-mm slice thickness. Signal-to-noise ratio was measured using 2 scans. The ssEPI-DWI sequence showed significant image blurring, whereas pTSE-DWI and rsEPI-DWI sequences demonstrated high image quality with low geometrical distortion compared with reference T2-weighted, turbo spin echo images. Signal loss in ventral regions near the air-filled paranasal sinus/nasal cavity was found in ssEPI-DWI and rsEPI-DWI but not pTSE-DWI. The apparent diffusion coefficient values for ssEPI-DWI were 824 ± 17 × 10 and 749 ± 25 × 10 mm/s in the gray matter and white matter, respectively; the values obtained for pTSE-DWI were 798 ± 21 × 10 and 865 ± 40 × 10 mm/s; and the values obtained for rsEPI-DWI were 730 ± 12 × 10 and 722 ± 25 × 10 mm/s. The pTSE-DWI images showed no additional distortion comparison to the T2-weighted images, but had a lower SNR than ssEPI-DWI and rsEPI-DWI. The rsEPI-DWI sequence provided high-quality images with minor distortion and a similar SNR to ssEPI-DWI. Our results suggest that the benefits of the rsEPI-DWI and pTSE-DWI sequences, in terms of SNR, image quality, and image distortion, appear to outweigh those of ssEPI-DWI. Thus, pTSE-DWI and rsEPI-DWI at 7 T have great potential use for clinical diagnoses. However, it is noteworthy that both

  5. Density‐weighted concentric circle trajectories for high resolution brain magnetic resonance spectroscopic imaging at 7T

    PubMed Central

    Hingerl, Lukas; Moser, Philipp; Považan, Michal; Hangel, Gilbert; Heckova, Eva; Gruber, Stephan; Trattnig, Siegfried; Strasser, Bernhard

    2017-01-01

    Purpose Full‐slice magnetic resonance spectroscopic imaging at ≥7 T is especially vulnerable to lipid contaminations arising from regions close to the skull. This contamination can be mitigated by improving the point spread function via higher spatial resolution sampling and k‐space filtering, but this prolongs scan times and reduces the signal‐to‐noise ratio (SNR) efficiency. Currently applied parallel imaging methods accelerate magnetic resonance spectroscopic imaging scans at 7T, but increase lipid artifacts and lower SNR‐efficiency further. In this study, we propose an SNR‐efficient spatial‐spectral sampling scheme using concentric circle echo planar trajectories (CONCEPT), which was adapted to intrinsically acquire a Hamming‐weighted k‐space, thus termed density‐weighted‐CONCEPT. This minimizes voxel bleeding, while preserving an optimal SNR. Theory and Methods Trajectories were theoretically derived and verified in phantoms as well as in the human brain via measurements of five volunteers (single‐slice, field‐of‐view 220 × 220 mm2, matrix 64 × 64, scan time 6 min) with free induction decay magnetic resonance spectroscopic imaging. Density‐weighted‐CONCEPT was compared to (a) the originally proposed CONCEPT with equidistant circles (here termed e‐CONCEPT), (b) elliptical phase‐encoding, and (c) 5‐fold Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration accelerated elliptical phase‐encoding. Results By intrinsically sampling a Hamming‐weighted k‐space, density‐weighted‐CONCEPT removed Gibbs‐ringing artifacts and had in vivo +9.5%, +24.4%, and +39.7% higher SNR than e‐CONCEPT, elliptical phase‐encoding, and the Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration accelerated elliptical phase‐encoding (all P < 0.05), respectively, which lead to improved metabolic maps. Conclusion Density‐weighted‐CONCEPT provides clinically attractive full‐slice high

  6. A study on the flip angle for an optimal T1-weighted image based on the 3D-THRIVE MRI technique: Focusing on the detection of a hepatocellular carcinoma (HCC)

    NASA Astrophysics Data System (ADS)

    Dong, Kyung-Rae; Goo, Eun-Hoe; Lee, Jae-Seung; Chung, Woon-Kwan; Kim, Young-Jae

    2014-04-01

    This study examined the optimal flip angle (FA) for a T1-weighted image in the detection of a hepatocellular carcinoma (HCC). A 3D-T1-weighted high-resolution isotropic volume examination (THRIVE) technique was used to determine the dependence of the signal to noise ratio (SNR) and the contrast-to-noise ratio (CNR) on the change in FA. This study targeted 40 liver cancer patients (25 men and 15 women aged 50 to 70 years with a mean age of 60.32 ± 6.2 years) who visited this hospital to undergo an abdominal MRI examination from January to June 2013. A 3.0 Tesla MRI machine (Philips, Medical System, Achieva) and a MRI receiver coil for data reception with a 16-channel multicoil were used in this study. The THRIVE (repetition time (TR): 8.1 ms, echo time (TE): 3.7 ms, matrix: 172 × 172, slice thickness: 4 mm, gap: 2 mm, field of view (FOV): 350 mm, and band width (BW): 380.1 Hz) technique was applied as a pulse sequence. The time required for the examination was 19 seconds, and the breath-hold technique was used. Axial images were obtained at five FAs: 5, 10, 15, 20 and 25°. The signal intensities of the liver, the lesion and the background noise were measured based on the acquired images before the SNR and the CNR were calculated. To evaluate the image at the FA, we used SPSS for Windows ver. 17.0 to conduct a one-way ANOVA test. A Bonferroni test was conducted as a post-hoc test. The SNRs of the hemorrhagic HCC in the 3D-THRIVE technique were 35.50 ± 4.12, 97.00 ± 10.24, 66.09 ± 7.29, 53.84 ± 5.43, and 42.92 ± 5.11 for FAs of 5, 10, 15, 20, and 25°, respectively (p = 0.0430), whereas the corresponding CNRs were 30.50 ± 3.84, 43.00 ± 5.42, 36.54 ± 4.09, 32.30 ± 2.79, and 31.69 ± 3.21 (p = 0.0003). At a small FA of 10, the SNR and the CNR showed the highest values. As the FA was increased, the SNR and the CNR values showed a decreasing tendency. In conclusion, the optimal T1-weighted image FA should be set to 10° to detect a HCC by using the 3D

  7. Carr-Purcell-Meiboom-Gill imaging of prostate cancer: quantitative T2 values for cancer discrimination.

    PubMed

    Roebuck, Joseph R; Haker, Steven J; Mitsouras, Dimitris; Rybicki, Frank J; Tempany, Clare M; Mulkern, Robert V

    2009-05-01

    Quantitative, apparent T(2) values of suspected prostate cancer and healthy peripheral zone tissue in men with prostate cancer were measured using a Carr-Purcell-Meiboom-Gill (CPMG) imaging sequence in order to assess the cancer discrimination potential of tissue T(2) values. The CPMG imaging sequence was used to image the prostates of 18 men with biopsy-proven prostate cancer. Whole gland coverage with nominal voxel volumes of 0.54 x 1.1 x 4 mm(3) was obtained in 10.7 min, resulting in data sets suitable for generating high-quality images with variable T(2)-weighting and for evaluating quantitative T(2) values on a pixel-by-pixel basis. Region-of-interest analysis of suspected healthy peripheral zone tissue and suspected cancer, identified on the basis of both T(1)- and T(2)-weighted signal intensities and available histopathology reports, yielded significantly (P<.0001) longer apparent T(2) values in suspected healthy tissue (193+/-49 ms) vs. suspected cancer (100+/-26 ms), suggesting potential utility of this method as a tissue specific discrimination index for prostate cancer. We conclude that CPMG imaging of the prostate can be performed in reasonable scan times and can provide advantages over T(2)-weighted fast spin echo (FSE) imaging alone, including quantitative T(2) values for cancer discrimination as well as proton density maps without the point spread function degradation associated with short effective echo time FSE sequences.

  8. Wideband Arrhythmia-Insensitive-Rapid (AIR) Pulse Sequence for Cardiac T1 mapping without Image Artifacts induced by ICD

    PubMed Central

    Hong, KyungPyo; Jeong, Eun-Kee; Wall, T. Scott; Drakos, Stavros G.; Kim, Daniel

    2015-01-01

    Purpose To develop and evaluate a wideband arrhythmia-insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by implantable-cardioverter-defibrillator (ICD). Methods We developed a wideband AIR pulse sequence by incorporating a saturation pulse with wide frequency bandwidth (8.9 kHz), in order to achieve uniform T1 weighting in the heart with ICD. We tested the performance of original and “wideband” AIR cardiac T1 mapping pulse sequences in phantom and human experiments at 1.5T. Results In 5 phantoms representing native myocardium and blood and post-contrast blood/tissue T1 values, compared with the control T1 values measured with an inversion-recovery pulse sequence without ICD, T1 values measured with original AIR with ICD were considerably lower (absolute percent error >29%), whereas T1 values measured with wideband AIR with ICD were similar (absolute percent error <5%). Similarly, in 11 human subjects, compared with the control T1 values measured with original AIR without ICD, T1 measured with original AIR with ICD was significantly lower (absolute percent error >10.1%), whereas T1 measured with wideband AIR with ICD was similar (absolute percent error <2.0%). Conclusion This study demonstrates the feasibility of a wideband pulse sequence for cardiac T1 mapping without significant image artifacts induced by ICD. PMID:25975192

  9. Semiautomated Segmentation of Polycystic Kidneys in T2-Weighted MR Images.

    PubMed

    Kline, Timothy L; Edwards, Marie E; Korfiatis, Panagiotis; Akkus, Zeynettin; Torres, Vicente E; Erickson, Bradley J

    2016-09-01

    The objective of the present study is to develop and validate a fast, accurate, and reproducible method that will increase and improve institutional measurement of total kidney volume and thereby avoid the higher costs, increased operator processing time, and inherent subjectivity associated with manual contour tracing. We developed a semiautomated segmentation approach, known as the minimal interaction rapid organ segmentation (MIROS) method, which results in human interaction during measurement of total kidney volume on MR images being reduced to a few minutes. This software tool automatically steps through slices and requires rough definition of kidney boundaries supplied by the user. The approach was verified on T2-weighted MR images of 40 patients with autosomal dominant polycystic kidney disease of varying degrees of severity. The MIROS approach required less than 5 minutes of user interaction in all cases. When compared with the ground-truth reference standard, MIROS showed no significant bias and had low variability (mean ± 2 SD, 0.19% ± 6.96%). The MIROS method will greatly facilitate future research studies in which accurate and reproducible measurements of cystic organ volumes are needed.

  10. MRI of the hip at 7T: feasibility of bone microarchitecture, high-resolution cartilage, and clinical imaging.

    PubMed

    Chang, Gregory; Deniz, Cem M; Honig, Stephen; Egol, Kenneth; Regatte, Ravinder R; Zhu, Yudong; Sodickson, Daniel K; Brown, Ryan

    2014-06-01

    To demonstrate the feasibility of performing bone microarchitecture, high-resolution cartilage, and clinical imaging of the hip at 7T. This study had Institutional Review Board approval. Using an 8-channel coil constructed in-house, we imaged the hips of 15 subjects on a 7T magnetic resonance imaging (MRI) scanner. We applied: 1) a T1-weighted 3D fast low angle shot (3D FLASH) sequence (0.23 × 0.23 × 1-1.5 mm(3) ) for bone microarchitecture imaging; 2) T1-weighted 3D FLASH (water excitation) and volumetric interpolated breath-hold examination (VIBE) sequences (0.23 × 0.23 × 1.5 mm(3) ) with saturation or inversion recovery-based fat suppression for cartilage imaging; 3) 2D intermediate-weighted fast spin-echo (FSE) sequences without and with fat saturation (0.27 × 0.27 × 2 mm) for clinical imaging. Bone microarchitecture images allowed visualization of individual trabeculae within the proximal femur. Cartilage was well visualized and fat was well suppressed on FLASH and VIBE sequences. FSE sequences allowed visualization of cartilage, the labrum (including cartilage and labral pathology), joint capsule, and tendons. This is the first study to demonstrate the feasibility of performing a clinically comprehensive hip MRI protocol at 7T, including high-resolution imaging of bone microarchitecture and cartilage, as well as clinical imaging. Copyright © 2013 Wiley Periodicals, Inc.

  11. Three-dimensional functional magnetic resonance imaging of human brain on a clinical 1.5-T scanner.

    PubMed Central

    van Gelderen, P; Ramsey, N F; Liu, G; Duyn, J H; Frank, J A; Weinberger, D R; Moonen, C T

    1995-01-01

    Functional magnetic resonance imaging (fMRI) is a tool for mapping brain function that utilizes neuronal activity-induced changes in blood oxygenation. An efficient three-dimensional fMRI method is presented for imaging brain activity on conventional, widely available, 1.5-T scanners, without additional hardware. This approach uses large magnetic susceptibility weighting based on the echo-shifting principle combined with multiple gradient echoes per excitation. Motor stimulation, induced by self-paced finger tapping, reliably produced significant signal increase in the hand region of the contralateral primary motor cortex in every subject tested. Images Fig. 2 Fig. 3 PMID:7624341

  12. Comparison of post-contrast 3D-T1-MPRAGE, 3D-T1-SPACE and 3D-T2-FLAIR MR images in evaluation of meningeal abnormalities at 3-T MRI.

    PubMed

    Jeevanandham, Balaji; Kalyanpur, Tejas; Gupta, Prashant; Cherian, Mathew

    2017-06-01

    This study was to assess the usefulness of newer three-dimensional (3D)-T 1 sampling perfection with application optimized contrast using different flip-angle evolutions (SPACE) and 3D-T 2 fluid-attenuated inversion recovery (FLAIR) sequences in evaluation of meningeal abnormalities. 78 patients who presented with high suspicion of meningeal abnormalities were evaluated using post-contrast 3D-T 2 -FLAIR, 3D-T 1 magnetization-prepared rapid gradient-echo (MPRAGE) and 3D-T 1 -SPACE sequences. The images were evaluated independently by two radiologists for cortical gyral, sulcal space, basal cisterns and dural enhancement. The diagnoses were confirmed by further investigations including histopathology. Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images yielded significantly more information than MPRAGE images (p < 0.05 for both SPACE and FLAIR images) in detection of meningeal abnormalities. SPACE images best demonstrated abnormalities in dural and sulcal spaces, whereas FLAIR was useful for basal cisterns enhancement. Both SPACE and FLAIR performed equally well in detection of gyral enhancement. In all 10 patients, where both SPACE and T 2 -FLAIR images failed to demonstrate any abnormality, further analysis was also negative. The 3D-T 1 -SPACE sequence best demonstrated abnormalities in dural and sulcal spaces, whereas FLAIR was useful for abnormalities in basal cisterns. Both SPACE and FLAIR performed holds good for detection of gyral enhancement. Post-contrast SPACE and FLAIR sequences are superior to the MPRAGE sequence for evaluation of meningeal abnormalities and when used in combination have the maximum sensitivity for leptomeningeal abnormalities. The negative-predictive value is nearly 100%, where no leptomeningeal abnormality was detected on these sequences. Advances in knowledge: Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images are more useful than 3D-T 1 -MPRAGE images in evaluation of meningeal abnormalities.

  13. T1 weighted fat/water separated PROPELLER acquired with dual bandwidths.

    PubMed

    Rydén, Henric; Berglund, Johan; Norbeck, Ola; Avventi, Enrico; Skare, Stefan

    2018-04-24

    To describe a fat/water separated dual receiver bandwidth (rBW) spin echo PROPELLER sequence that eliminates the dead time associated with single rBW sequences. A nonuniform noise whitening by regularization of the fat/water inverse problem is proposed, to enable dual rBW reconstructions. Bipolar, flyback, and dual spin echo sequences were developed. All sequences acquire two echoes with different rBW without dead time. Chemical shift displacement was corrected by performing the fat/water separation in k-space, prior to gridding. The proposed sequences were compared to fat saturation, and single rBW sequences, in terms of SNR and CNR efficiency, using clinically relevant acquisition parameters. The impact of motion was investigated. Chemical shift correction greatly improved the image quality, especially at high resolution acquired with low rBW, and also improved motion estimates. SNR efficiency of the dual spin echo sequence was up to 20% higher than the single rBW acquisition, while CNR efficiency was 50% higher for the bipolar acquisition. Noise whitening was deemed necessary for all dual rBW acquisitions, rendering high image quality with strong and homogenous fat suppression. Dual rBW sequences eliminate the dead time present in single rBW sequences, which improves SNR efficiency. In combination with the proposed regularization, this enables highly efficient T1-weighted PROPELLER images without chemical shift displacement. © 2018 International Society for Magnetic Resonance in Medicine.

  14. Carr-Purcell-Meiboom-Gill (CPMG) Imaging of Prostate Cancer: Quantitative T2 Values for Cancer Discrimination

    PubMed Central

    Roebuck, Joseph R.; Haker, Steven J.; Mitsouras, Dimitris; Rybicki, Frank J.; Tempany, Clare M.; Mulkern, Robert V.

    2009-01-01

    Quantitative, apparent T2 values of suspected prostate cancer and healthy peripheral zone tissue in men with prostate cancer were measured using a Carr-Purcell-Meiboom-Gill (CPMG) imaging sequence in order to assess the cancer discrimination potential of tissue T2 values. The CPMG imaging sequence was used to image the prostates of 18 men with biopsy proven prostate cancer. Whole gland coverage with nominal voxel volumes of 0.54 × 1.1 × 4 mm3 was obtained in 10.7 minutes, resulting in data sets suitable for generating high quality images with variable T2-weighting and for evaluating quantitative T2 values on a pixel-by-pixel basis. Region-of-interest analysis of suspected healthy peripheral zone tissue and suspected cancer, identified on the basis of both T1- and T2-weighted signal intensities and available histopathology reports, yielded significantly (p < 0.0001) longer apparent T2 values in suspected healthy tissue (193 ± 49 ms) vs. suspected cancer (100 ± 26 ms), suggesting potential utility of this method as a tissue specific discrimination index for prostate cancer. We conclude that CPMG imaging of the prostate can be performed in reasonable scan times and can provide advantages over T2-weighted fast spin echo imaging alone, including quantitative T2 values for cancer discrimination as well as proton density maps without the point spread function degradation associated with short effective echo time fast spin echo (FSE) sequences. PMID:18823731

  15. Body image and weight control in South Africans 15 years or older: SANHANES-1.

    PubMed

    Mchiza, Zandile J; Parker, Whadi-Ah; Makoae, Mokhantso; Sewpaul, Ronel; Kupamupindi, Takura; Labadarios, Demetre

    2015-09-30

    South African studies have suggested that differences in obesity prevalence between groups may be partly related to differences in body image and body size dissatisfaction. However, there has never been a national study that measured body image and its relationship to weight control in the country. Hence, the main aim of the study was to examine body image in relation to body mass index and weight control in South Africa. A cross-sectional survey and a secondary analyses of data were undertaken for 6 411 South Africans (15+ years) participating in the first South African National Health and Nutrition Examination Survey. Body image was investigated in relation to weight status and attempts to lose or gain weight. Data were analysed using STATA version 11.0. Descriptive statistics are presented as counts (numbers), percentages, means, standard error of means, and 95 % confidence intervals. Any differences in values were considered to be significantly different if the confidence intervals did not overlap. Overall, 84.5 % participants had a largely distorted body image and 45.3 % were highly dissatisfied about their body size. Overweight and obese participants under estimated their body size and desired to be thinner. On the other hand, normal- and under-weight participants over estimated their body size and desired to be fatter. Only 12.1 and 10.1 % of participants attempted to lose or gain weight, respectively, mainly by adjusting dietary intake and physical activity. Body mass index appears to influence body image and weight adjustment in South Africa. South Africans at the extreme ends of the body mass index range have a largely distorted body image and are highly dissatisfied by it. This suggests a need for health education and beneficial weight control strategies to halt the obesity epidemic in the country.

  16. Tuning the non-covalent confinement of Gd(III) complexes in silica nanoparticles for high T1-weighted MR imaging capability.

    PubMed

    Fedorenko, Svetlana V; Grechkina, Svetlana L; Mustafina, Asiya R; Kholin, Kirill V; Stepanov, Alexey S; Nizameev, Irek R; Ismaev, Ildus E; Kadirov, Marsil K; Zairov, Rustem R; Fattakhova, Alfia N; Amirov, Rustem R; Soloveva, Svetlana E

    2017-01-01

    The present work introduces deliberate synthesis of Gd(III)-doped silica nanoparticles with high relaxivity at magnetic field strengths below 1.5T. Modified microemulsion water-in-oil procedure was used in order to achieve superficial localization of Gd(III) complexes within 40-55nm sized silica spheres. The relaxivities of the prepared nanoparticles were measured at 0.47, 1.41 and 1.5T with the use of both NMR analyzer and whole body NMR scanner. Longitudinal relaxivities of the obtained silica nanoparticles reveal significant dependence on the confinement mode, changing from 4.1 to 49.6mM -1 s -1 at 0.47T when the localization of Gd(III) complexes changes from core to superficial zones of the silica spheres. The results highlight predominant contribution of the complexes located close to silica/water interface to the relaxivity of the nanoparticles. Low effect of blood proteins on the relaxivity in the aqueous colloids of the nanoparticles was exemplified by serum bovine albumin. T 1 - weighted MRI data indicate that the nanoparticles provide strong positive contrast at 1.5T, which along with low cytotoxicity effect make a good basis for their application as contrast agents. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. "Smart" theranostic lanthanide nanoprobes with simultaneous up-conversion fluorescence and tunable T1-T2 magnetic resonance imaging contrast and near-infrared activated photodynamic therapy.

    PubMed

    Zhang, Yan; Das, Gautom Kumar; Vijayaragavan, Vimalan; Xu, Qing Chi; Padmanabhan, Parasuraman; Bhakoo, Kishore K; Selvan, Subramanian Tamil; Tan, Timothy Thatt Yang

    2014-11-07

    The current work reports a type of "smart" lanthanide-based theranostic nanoprobe, NaDyF4:Yb(3+)/NaGdF4:Yb(3+),Er(3+), which is able to circumvent the up-converting poisoning effect of Dy(3+) ions to give efficient near infrared (980 nm) triggered up-conversion fluorescence, and offers not only excellent dark T2-weighted MR contrast but also tunable bright and T1-weighted MR contrast properties. Due to the efficient up-converted energy transfer from the nanocrystals to chlorin e6 (Ce6) photosensitizers loaded onto the nanocrystals, cytotoxic singlet oxygen was generated and photodynamic therapy was demonstrated. Therefore, the current multifunctional nanocrystals could be potentially useful in various image-guided diagnoses where bright or dark MRI contrast could be selectively tuned to optimize image quality, but also as an efficient and more penetrative near-infrared activated photodynamic therapy agent.

  18. Repeatability of Brain Volume Measurements Made with the Atlas-based Method from T1-weighted Images Acquired Using a 0.4 Tesla Low Field MR Scanner.

    PubMed

    Goto, Masami; Suzuki, Makoto; Mizukami, Shinya; Abe, Osamu; Aoki, Shigeki; Miyati, Tosiaki; Fukuda, Michinari; Gomi, Tsutomu; Takeda, Tohoru

    2016-10-11

    An understanding of the repeatability of measured results is important for both the atlas-based and voxel-based morphometry (VBM) methods of magnetic resonance (MR) brain volumetry. However, many recent studies that have investigated the repeatability of brain volume measurements have been performed using static magnetic fields of 1-4 tesla, and no study has used a low-strength static magnetic field. The aim of this study was to investigate the repeatability of measured volumes using the atlas-based method and a low-strength static magnetic field (0.4 tesla). Ten healthy volunteers participated in this study. Using a 0.4 tesla magnetic resonance imaging (MRI) scanner and a quadrature head coil, three-dimensional T 1 -weighted images (3D-T 1 WIs) were obtained from each subject, twice on the same day. VBM8 software was used to construct segmented normalized images [gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) images]. The regions-of-interest (ROIs) of GM, WM, CSF, hippocampus (HC), orbital gyrus (OG), and cerebellum posterior lobe (CPL) were generated using WFU PickAtlas. The percentage change was defined as[100 × (measured volume with first segmented image - mean volume in each subject)/(mean volume in each subject)]The average percentage change was calculated as the percentage change in the 6 ROIs of the 10 subjects. The mean of the average percentage changes for each ROI was as follows: GM, 0.556%; WM, 0.324%; CSF, 0.573%; HC, 0.645%; OG, 1.74%; and CPL, 0.471%. The average percentage change was higher for the orbital gyrus than for the other ROIs. We consider that repeatability of the atlas-based method is similar between 0.4 and 1.5 tesla MR scanners. To our knowledge, this is the first report to show that the level of repeatability with a 0.4 tesla MR scanner is adequate for the estimation of brain volume change by the atlas-based method.

  19. Contrasting weight changes with LY2605541, a novel long-acting insulin, and insulin glargine despite similar improved glycaemic control in T1DM and T2DM.

    PubMed

    Jacober, S J; Rosenstock, J; Bergenstal, R M; Prince, M J; Qu, Y; Beals, J M

    2014-04-01

    The basal insulin analogue LY2605541, a PEGylated insulin lispro with prolonged duration of action, was previously shown to be associated with modest weight loss in Phase 2, randomized, open-label trials in type 2 (N=288) and type 1 (N=137) diabetes mellitus (T2DM and T1DM), compared with modest weight gain with insulin glargine. Exploratory analyses were conducted to further characterize these findings. Pearson correlations between change in body weight and other variables were calculated. Continuous variables were analysed using a mixed linear model with repeated measurements. Proportions of subjects with weight loss were analysed using Fisher's exact test for T2DM and Nagelkerke's method for T1DM. Weight loss was more common in LY2605541-treated patients than in patients treated with insulin glargine (T2DM: 56.9 vs. 40.2%, p=0.011; T1DM: 66.1 vs. 40.3%, p<0.001). More LY2605541-treated patients experienced ≥5% weight loss compared to patients treated with glargine (T2DM: 4.8 vs. 0%, p=0.033; T1DM: 11.9 vs. 0.8%, p<0.001). In both the T1DM and T2DM studies, weight change did not correlate with baseline body mass index (BMI), or change in HDL-cholesterol in either treatment group. No consistent correlations were found across both studies between weight change and any of the variables assessed; however, weight change was significantly correlated with hypoglycaemia rate in glargine-treated T2DM patients. In two Phase 2 trials, improved glycaemic control with long-acting basal insulin analogue LY2605541 is associated with weight loss in previously insulin-treated patients. This weight change is independent of baseline BMI or hypoglycaemia.

  20. Intensity standardisation of 7T MR images for intensity-based segmentation of the human hypothalamus

    PubMed Central

    Schreiber, Jan; Bazin, Pierre-Louis; Trampel, Robert; Anwander, Alfred; Geyer, Stefan; Schönknecht, Peter

    2017-01-01

    The high spatial resolution of 7T MRI enables us to identify subtle volume changes in brain structures, providing potential biomarkers of mental disorders. Most volumetric approaches require that similar intensity values represent similar tissue types across different persons. By applying colour-coding to T1-weighted MP2RAGE images, we found that the high measurement accuracy achieved by high-resolution imaging may be compromised by inter-individual variations in the image intensity. To address this issue, we analysed the performance of five intensity standardisation techniques in high-resolution T1-weighted MP2RAGE images. Twenty images with extreme intensities in the GM and WM were standardised to a representative reference image. We performed a multi-level evaluation with a focus on the hypothalamic region—analysing the intensity histograms as well as the actual MR images, and requiring that the correlation between the whole-brain tissue volumes and subject age be preserved during standardisation. The results were compared with T1 maps. Linear standardisation using subcortical ROIs of GM and WM provided good results for all evaluation criteria: it improved the histogram alignment within the ROIs and the average image intensity within the ROIs and the whole-brain GM and WM areas. This method reduced the inter-individual intensity variation of the hypothalamic boundary by more than half, outperforming all other methods, and kept the original correlation between the GM volume and subject age intact. Mixed results were obtained for the other four methods, which sometimes came at the expense of unwarranted changes in the age-related pattern of the GM volume. The mapping of the T1 relaxation time with the MP2RAGE sequence is advertised as being especially robust to bias field inhomogeneity. We found little evidence that substantiated the T1 map’s theoretical superiority over the T1-weighted images regarding the inter-individual image intensity homogeneity. PMID

  1. Boosting the SNR by adding a receive-only endorectal monopole to an external antenna array for high-resolution, T2 -weighted imaging of early-stage cervical cancer with 7-T MRI.

    PubMed

    van Kalleveen, I M L; Hoogendam, J P; Raaijmakers, A J E; Visser, F; Arteaga de Castro, C S; Verheijen, R H M; Luijten, P R; Zweemer, R P; Veldhuis, W B; Klomp, D W J

    2017-09-01

    The aim of this study was to investigate the signal-to-noise ratio (SNR) gain in early-stage cervical cancer at ultrahigh-field MRI (e.g. 7 T) using a combination of multiple external antennas and a single endorectal antenna. In particular, we used an endorectal monopole antenna to increase the SNR in cervical magnetic resonance imaging (MRI). This should allow high-resolution, T 2 -weighted imaging and magnetic resonance spectroscopy (MRS) for metabolic staging, which could facilitate the local tumor status assessment. In a prospective feasibility study, five healthy female volunteers and six patients with histologically proven stage IB1-IIB cervical cancer were scanned at 7 T. We used seven external fractionated dipole antennas for transmit-receive (transceive) and an endorectally placed monopole antenna for reception only. A region of interest, containing both normal cervix and tumor tissue, was selected for the SNR measurement. Separated signal and noise measurements were obtained in the region of the cervix for each element and in the near field of the monopole antenna (radius < 30 mm) to calculate the SNR gain of the endorectal antenna in each patient. We obtained high-resolution, T 2 -weighted images with a voxel size of 0.7 × 0.8 × 3.0 mm 3 . In four cases with optimal placement of the endorectal antenna (verified on the T 2 -weighted images), a mean gain of 2.2 in SNR was obtained at the overall cervix and tumor tissue area. Within a radius of 30 mm from the monopole antenna, a mean SNR gain of 3.7 was achieved in the four optimal cases. Overlap between the two different regions of the SNR calculations was around 24%. We have demonstrated that the use of an endorectal monopole antenna substantially increases the SNR of 7-T MRI at the cervical anatomy. Combined with the intrinsically high SNR of ultrahigh-field MRI, this gain may be employed to obtain metabolic information using MRS and to enhance spatial resolutions to assess tumor invasion

  2. T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI

    PubMed Central

    Kang, Kyung A; Kim, EunJu; Jeong, Woo Kyoung; Choi, Dongil; Lee, Won Jae; Jung, Sin-Ho; Baek, Sun-Young

    2015-01-01

    Objective To assess the value of applying MultiVane to liver T2-weighted imaging (T2WI) compared with conventional T2WIs with emphasis on detection of focal liver lesions. Materials and Methods Seventy-eight patients (43 men and 35 women) with 86 hepatic lesions and 20 pancreatico-biliary diseases underwent MRI including T2WIs acquired using breath-hold (BH), respiratory-triggered (RT), and MultiVane technique at 3T. Two reviewers evaluated each T2WI with respect to artefacts, organ sharpness, and conspicuity of intrahepatic vessels, hilar duct, and main lesion using five-point scales, and made pairwise comparisons between T2WI sequences for these categories. Diagnostic accuracy (Az) and sensitivity for hepatic lesion detection were evaluated using alternative free-response receiver operating characteristic analysis. Results MultiVane T2WI was significantly better than BH-T2WI or RT-T2WI for organ sharpness and conspicuity of intrahepatic vessels and main lesion in both separate reviews and pairwise comparisons (p < 0.001). With regard to motion artefacts, MultiVane T2WI or BH-T2WI was better than RT-T2WI (p < 0.001). Conspicuity of hilar duct was better with BH-T2WI than with MultiVane T2WI (p = 0.030) or RT-T2WI (p < 0.001). For detection of 86 hepatic lesions, sensitivity (mean, 97.7%) of MultiVane T2WI was significantly higher than that of BH-T2WI (mean, 89.5%) (p = 0.008) or RT-T2WI (mean, 84.9%) (p = 0.001). Conclusion Applying the MultiVane technique to T2WI of the liver is a promising approach to improving image quality that results in increased detection of focal liver lesions compared with conventional T2WI. PMID:26357498

  3. T2- and diffusion-weighted magnetic resonance imaging at 3T for the detection of prostate cancer with and without endorectal coil: An intraindividual comparison of image quality and diagnostic performance.

    PubMed

    Baur, Alexander D J; Daqqaq, Tareef; Wagner, Moritz; Maxeiner, Andreas; Huppertz, Alexander; Renz, Diane; Hamm, Bernd; Fischer, Thomas; Durmus, Tahir

    2016-06-01

    To intraindividually compare image quality and diagnostic performance of multiparametric MRI (mpMRI) at 3T for the detection of prostate cancer (PCa) using a pelvic phased-array coil (PAC) and a combined endorectal and pelvic phased-array coil (ERC-PAC). Forty-five patients were prospectively included and received mpMRI of the prostate using a PAC and an ERC-PAC during one imaging session. Two radiologists evaluated image quality and the most suspicious lesion according to the PI-RADS scoring system. Results of MRI-TRUS-fusion biopsy of the prostate served as reference standard. Patient comfort and acceptance were assessed using a standardized questionnaire. Overall image quality for T2WI was rated significantly better with an ERC-PAC compared to a PAC (p=0.0038). The weighted kappa for PI-RADS scores for T2WI and DWI with a PAC and an ERC-PAC was 0.70 and 0.73, respectively. For a PI-RADS sum score including T2WI and DWI the area under the curve with a PAC and an ERC-PAC were 0.95-0.99 and 0.93-0.97, respectively (p=0.1395). For T2WI and DWI performed at 3T index PCa lesion identification and evaluation did not differ significantly with both coil setups. Patients preferred MRI without an ERC. Therefore, the use of an ERC may be omitted in a prostate cancer detection setting. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Gd-doped BNNTs as T2-weighted MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Ciofani, Gianni; Boni, Adriano; Calucci, Lucia; Forte, Claudia; Gozzi, Alessandro; Mazzolai, Barbara; Mattoli, Virgilio

    2013-08-01

    This work describes, for the first time, doping of boron nitride nanotubes (BNNTs) with gadolinium (Gd@BNNTs), a stable functionalization that permits non-invasive BNNT tracking via magnetic resonance imaging (MRI). We report the structure, Gd loading, and relaxometric properties in water suspension at 7 T of Gd@BNNTs, and show the behaviour of these nanostructures as promising T2-weighted contrast agents. Finally, we demonstrate their complete biocompatibility in vitro on human neuroblastoma cells, together with their ability to effectively label and affect contrast in MRI images at 7 T.

  5. Early Detection of Hypothermic Neuroprotection Using T2-Weighted Magnetic Resonance Imaging in a Mouse Model of Hypoxic Ischemic Encephalopathy.

    PubMed

    Doman, Sydney E; Girish, Akanksha; Nemeth, Christina L; Drummond, Gabrielle T; Carr, Patrice; Garcia, Maxine S; Johnston, Michael V; Kannan, Sujatha; Fatemi, Ali; Zhang, Jiangyang; Wilson, Mary Ann

    2018-01-01

    Perinatal hypoxic-ischemic encephalopathy (HIE) can lead to neurodevelopmental disorders, including cerebral palsy. Standard care for neonatal HIE includes therapeutic hypothermia, which provides partial neuroprotection; magnetic resonance imaging (MRI) is often used to assess injury and predict outcome after HIE. Immature rodent models of HIE are used to evaluate mechanisms of injury and to examine the efficacy and mechanisms of neuroprotective interventions such as hypothermia. In this study, we first confirmed that, in the CD1 mouse model of perinatal HIE used for our research, MRI obtained 3 h after hypoxic ischemia (HI) could reliably assess initial brain injury and predict histopathological outcome. Mice were subjected to HI (unilateral carotid ligation followed by exposure to hypoxia) on postnatal day 7 and were imaged with T2-weighted MRI and diffusion-weighted MRI (DWI), 3 h after HI. Clearly defined regions of increased signal were comparable in T2 MRI and DWI, and we found a strong correlation between T2 MRI injury scores 3 h after HI and histopathological brain injury 7 days after HI, validating this method for evaluating initial injury in this model of HIE. The more efficient, higher resolution T2 MRI was used to score initial brain injury in subsequent studies. In mice treated with hypothermia, we found a significant reduction in T2 MRI injury scores 3 h after HI, compared to normothermic littermates. Early hypothermic neuroprotection was maintained 7 days after HI, in both T2 MRI injury scores and histopathology. In the normothermic group, T2 MRI injury scores 3 h after HI were comparable to those obtained 7 days after HI. However, in the hypothermic group, brain injury was significantly less 7 days after HI than at 3 h. Thus, early neuroprotective effects of hypothermia were enhanced by 7 days, which may reflect the additional 3 h of hypothermia after imaging or effects on later mechanisms of injury, such as delayed cell

  6. Early Detection of Hypothermic Neuroprotection Using T2-Weighted Magnetic Resonance Imaging in a Mouse Model of Hypoxic Ischemic Encephalopathy

    PubMed Central

    Doman, Sydney E.; Girish, Akanksha; Nemeth, Christina L.; Drummond, Gabrielle T.; Carr, Patrice; Garcia, Maxine S.; Johnston, Michael V.; Kannan, Sujatha; Fatemi, Ali; Zhang, Jiangyang; Wilson, Mary Ann

    2018-01-01

    Perinatal hypoxic-ischemic encephalopathy (HIE) can lead to neurodevelopmental disorders, including cerebral palsy. Standard care for neonatal HIE includes therapeutic hypothermia, which provides partial neuroprotection; magnetic resonance imaging (MRI) is often used to assess injury and predict outcome after HIE. Immature rodent models of HIE are used to evaluate mechanisms of injury and to examine the efficacy and mechanisms of neuroprotective interventions such as hypothermia. In this study, we first confirmed that, in the CD1 mouse model of perinatal HIE used for our research, MRI obtained 3 h after hypoxic ischemia (HI) could reliably assess initial brain injury and predict histopathological outcome. Mice were subjected to HI (unilateral carotid ligation followed by exposure to hypoxia) on postnatal day 7 and were imaged with T2-weighted MRI and diffusion-weighted MRI (DWI), 3 h after HI. Clearly defined regions of increased signal were comparable in T2 MRI and DWI, and we found a strong correlation between T2 MRI injury scores 3 h after HI and histopathological brain injury 7 days after HI, validating this method for evaluating initial injury in this model of HIE. The more efficient, higher resolution T2 MRI was used to score initial brain injury in subsequent studies. In mice treated with hypothermia, we found a significant reduction in T2 MRI injury scores 3 h after HI, compared to normothermic littermates. Early hypothermic neuroprotection was maintained 7 days after HI, in both T2 MRI injury scores and histopathology. In the normothermic group, T2 MRI injury scores 3 h after HI were comparable to those obtained 7 days after HI. However, in the hypothermic group, brain injury was significantly less 7 days after HI than at 3 h. Thus, early neuroprotective effects of hypothermia were enhanced by 7 days, which may reflect the additional 3 h of hypothermia after imaging or effects on later mechanisms of injury, such as delayed cell

  7. MR imaging of meniscal tears: comparison of intermediate-weighted FRFSE imaging with intermediate-weighted FSE imaging.

    PubMed

    Tokuda, Osamu; Harada, Yuko; Ueda, Takaaki; Iida, Etsushi; Shiraishi, Gen; Motomura, Tetsuhisa; Fukuda, Kouji; Matsunaga, Naofumi

    2012-11-01

    We compared intermediate-weighted fast spin-echo (IW-FSE) images with intermediate-weighted fast-recovery FSE (IW-FRFSE) images in the diagnosis of meniscal tears. First, 64 patients were recruited, and the arthroscopic findings (n = 40) and image analysis (n = 19) identified 59 torn menisci with 36 patients. Both the diagnostic performance and image quality in assessing meniscal tears was evaluated for IW-FSE and IW-FRFSE images using a four-point scale. Signal-to-noise ratio (SNR) calculation was performed for both sets of images. IW-FRFSE image specificity (100 %) for diagnosing the posterior horn of the medial meniscus (MM) tear with reader 1 was significantly higher than that of IW-FSE images (90 %). Mean ratings of the contrast between the lesion and normal signal intensity within the meniscus were significantly higher for the IW-FRFSE image ratings than the IW-FSE images in most meniscal tears. Mean SNRs were significantly higher for IW-FSE images than for IW-FRFSE images (P < 0.05). IW-FRFSE imaging can be used as an alternative to the IW-FSE imaging to evaluate meniscal tears.

  8. Normalization of cortical thickness measurements across different T1 magnetic resonance imaging protocols by novel W-Score standardization.

    PubMed

    Chung, Jinyong; Yoo, Kwangsun; Lee, Peter; Kim, Chan Mi; Roh, Jee Hoon; Park, Ji Eun; Kim, Sang Joon; Seo, Sang Won; Shin, Jeong-Hyeon; Seong, Joon-Kyung; Jeong, Yong

    2017-10-01

    The use of different 3D T1-weighted magnetic resonance (T1 MR) imaging protocols induces image incompatibility across multicenter studies, negating the many advantages of multicenter studies. A few methods have been developed to address this problem, but significant image incompatibility still remains. Thus, we developed a novel and convenient method to improve image compatibility. W-score standardization creates quality reference values by using a healthy group to obtain normalized disease values. We developed a protocol-specific w-score standardization to control the protocol effect, which is applied to each protocol separately. We used three data sets. In dataset 1, brain T1 MR images of normal controls (NC) and patients with Alzheimer's disease (AD) from two centers, acquired with different T1 MR protocols, were used (Protocol 1 and 2, n = 45/group). In dataset 2, data from six subjects, who underwent MRI with two different protocols (Protocol 1 and 2), were used with different repetition times, echo times, and slice thicknesses. In dataset 3, T1 MR images from a large number of healthy normal controls (Protocol 1: n = 148, Protocol 2: n = 343) were collected for w-score standardization. The protocol effect and disease effect on subjects' cortical thickness were analyzed before and after the application of protocol-specific w-score standardization. As expected, different protocols resulted in differing cortical thickness measurements in both NC and AD subjects. Different measurements were obtained for the same subject when imaged with different protocols. Multivariate pattern difference between measurements was observed between the protocols. Classification accuracy between two protocols was nearly 90%. After applying protocol-specific w-score standardization, the differences between the protocols substantially decreased. Most importantly, protocol-specific w-score standardization reduced both univariate and multivariate differences in the images while

  9. Evaluating Mesorectal Lymph Nodes in Rectal Cancer Before and After Neoadjuvant Chemoradiation Using Thin-Section T2-Weighted Magnetic Resonance Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koh, Dow-Mu; Chau, Ian; Tait, Diana

    2008-06-01

    Purpose: To apply thin-section T2-weighted magnetic resoance imaging (MRI) to evaluate the number, size, distribution, and morphology of benign and malignant mesorectal lymph nodes before and after chemoradiation treatment compared with histopathologic findings. Methods and Materials: Twenty-five patients with poor-risk adenocarcinoma of the rectum treated with neoadjuvant chemoradiation were evaluated prospectively. Thin-section T2-weighted MR images obtained before and after chemoradiation treatment were independently reviewed in consensus by 2 expert radiologists to determine the tumor stage, nodal size, nodal distribution, and nodal stage. Total mesorectal excision surgery after chemoradiation allowed MR nodal stage to be compared with histopathology using {kappa} statistics.more » Nodal downstaging was compared using the Chi-square test. Results: Before chemoradiation, 152 mesorectal nodes were visible (mean, 6.2 mm; 100 benign, 52 malignant) and 4 of 52 malignant nodes were in contact with the mesorectal fascia. The nodal staging was 7/25 N0, 10/25 N1, and 7/25 N2. After chemoradiation, only 29 nodes (mean, 4.1 mm; 24 benign, 5 malignant) were visible, and none were in contact with the mesorectal fascia. Nodal downstaging was observed: 20/25 N0 and 5/25 N1 (p < 0.01, Chi-square test). There was good agreement between MRI and pathologic T-staging ({kappa} = 0.64) and N-staging ({kappa} = 0.65) after chemoradiation. Conclusions: Neoadjuvant chemoradiation treatment resulted in a decrease in size and number of malignant- and benign-appearing mesorectal nodes on MRI. Nodal downstaging and nodal regression from the mesorectal fascia were observed after treatment. MRI is a useful tool for assessing nodal response to neoadjuvant treatment.« less

  10. Magnetic resonance fingerprinting using echo-planar imaging: Joint quantification of T1 and T2∗ relaxation times.

    PubMed

    Rieger, Benedikt; Zimmer, Fabian; Zapp, Jascha; Weingärtner, Sebastian; Schad, Lothar R

    2017-11-01

    To develop an implementation of the magnetic resonance fingerprinting (MRF) paradigm for quantitative imaging using echo-planar imaging (EPI) for simultaneous assessment of T 1 and T2∗. The proposed MRF method (MRF-EPI) is based on the acquisition of 160 gradient-spoiled EPI images with rapid, parallel-imaging accelerated, Cartesian readout and a measurement time of 10 s per slice. Contrast variation is induced using an initial inversion pulse, and varying the flip angles, echo times, and repetition times throughout the sequence. Joint quantification of T 1 and T2∗ is performed using dictionary matching with integrated B1+ correction. The quantification accuracy of the method was validated in phantom scans and in vivo in 6 healthy subjects. Joint T 1 and T2∗ parameter maps acquired with MRF-EPI in phantoms are in good agreement with reference measurements, showing deviations under 5% and 4% for T 1 and T2∗, respectively. In vivo baseline images were visually free of artifacts. In vivo relaxation times are in good agreement with gold-standard techniques (deviation T 1 : 4 ± 2%, T2∗: 4 ± 5%). The visual quality was comparable to the in vivo gold standard, despite substantially shortened scan times. The proposed MRF-EPI method provides fast and accurate T 1 and T2∗ quantification. This approach offers a rapid supplement to the non-Cartesian MRF portfolio, with potentially increased usability and robustness. Magn Reson Med 78:1724-1733, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  11. Early postnatal myelin content estimate of white matter via T1w/T2w ratio

    NASA Astrophysics Data System (ADS)

    Lee, Kevin; Cherel, Marie; Budin, Francois; Gilmore, John; Zaldarriaga Consing, Kirsten; Rasmussen, Jerod; Wadhwa, Pathik D.; Entringer, Sonja; Glasser, Matthew F.; Van Essen, David C.; Buss, Claudia; Styner, Martin

    2015-03-01

    To develop and evaluate a novel processing framework for the relative quantification of myelin content in cerebral white matter (WM) regions from brain MRI data via a computed ratio of T1 to T2 weighted intensity values. We employed high resolution (1mm3 isotropic) T1 and T2 weighted MRI from 46 (28 male, 18 female) neonate subjects (typically developing controls) scanned on a Siemens Tim Trio 3T at UC Irvine. We developed a novel, yet relatively straightforward image processing framework for WM myelin content estimation based on earlier work by Glasser, et al. We first co-register the structural MRI data to correct for motion. Then, background areas are masked out via a joint T1w and T2 foreground mask computed. Raw T1w/T2w-ratios images are computed next. For purpose of calibration across subjects, we first coarsely segment the fat-rich facial regions via an atlas co-registration. Linear intensity rescaling based on median T1w/T2w-ratio values in those facial regions yields calibrated T1w/T2wratio images. Mean values in lobar regions are evaluated using standard statistical analysis to investigate their interaction with age at scan. Several lobes have strongly positive significant interactions of age at scan with the computed T1w/T2w-ratio. Most regions do not show sex effects. A few regions show no measurable effects of change in myelin content change within the first few weeks of postnatal development, such as cingulate and CC areas, which we attribute to sample size and measurement variability. We developed and evaluated a novel way to estimate white matter myelin content for use in studies of brain white matter development.

  12. T1, diffusion tensor, and quantitative magnetization transfer imaging of the hippocampus in an Alzheimer's disease mouse model.

    PubMed

    Whittaker, Heather T; Zhu, Shenghua; Di Curzio, Domenico L; Buist, Richard; Li, Xin-Min; Noy, Suzanna; Wiseman, Frances K; Thiessen, Jonathan D; Martin, Melanie

    2018-07-01

    Alzheimer's disease (AD) pathology causes microstructural changes in the brain. These changes, if quantified with magnetic resonance imaging (MRI), could be studied for use as an early biomarker for AD. The aim of our study was to determine if T 1 relaxation, diffusion tensor imaging (DTI), and quantitative magnetization transfer imaging (qMTI) metrics could reveal changes within the hippocampus and surrounding white matter structures in ex vivo transgenic mouse brains overexpressing human amyloid precursor protein with the Swedish mutation. Delineation of hippocampal cell layers using DTI color maps allows more detailed analysis of T 1 -weighted imaging, DTI, and qMTI metrics, compared with segmentation of gross anatomy based on relaxation images, and with analysis of DTI or qMTI metrics alone. These alterations are observed in the absence of robust intracellular Aβ accumulation or plaque deposition as revealed by histology. This work demonstrates that multiparametric quantitative MRI methods are useful for characterizing changes within the hippocampal substructures and surrounding white matter tracts of mouse models of AD. Copyright © 2018. Published by Elsevier Inc.

  13. Topographic Diagnosis of Craniopharyngiomas: The Accuracy of MRI Findings Observed on Conventional T1 and T2 Images.

    PubMed

    Prieto, R; Pascual, J M; Barrios, L

    2017-11-01

    The topography of craniopharyngiomas has proved fundamental in predicting the involvement of vital brain structures and the possibility of achieving a safe radical resection. Beyond the imprecise term "suprasellar," indiscriminately used for craniopharyngiomas, an accurate definition of craniopharyngioma topography should be assessed by preoperative MR imaging. The objective of this study was to investigate the MRI findings that help define craniopharyngioma topography. This study retrospectively investigated a cohort of 200 surgically treated craniopharyngiomas with their corresponding preoperative midsagittal and coronal conventional T1- and T2-weighted MR images, along with detailed descriptions of the surgical findings. Radiologic variables related to the occupation of the tumor of intracranial compartments and the distortions of anatomic structures along the sella turcica-third ventricle axis were analyzed and correlated with the definitive craniopharyngioma topography observed during the surgical procedures. A predictive model for craniopharyngioma topography was generated by multivariate analysis. Five major craniopharyngioma topographies can be defined according to the degree of hypothalamic distortion caused by the tumor: sellar-suprasellar, pseudointraventricular, secondary intraventricular, not strictly intraventricular, and strictly intraventricular. Seven key radiologic variables identified on preoperative MRI allowed a correct overall prediction of craniopharyngioma topography in 86% of cases: 1) third ventricle occupation, 2) pituitary stalk distortion, 3) relative level of the hypothalamus in relation to the tumor, 4) chiasmatic cistern occupation, 5) mammillary body angle, 6) type of chiasm distortion, and 7) tumor shape. Systematic assessment of these 7 variables on conventional preoperative T1 and T2 MRI is a useful and reliable method to ascertain individual craniopharyngioma topography. © 2017 by American Journal of Neuroradiology.

  14. Image quality stability of whole-body diffusion weighted imaging.

    PubMed

    Chen, Yun-bin; Hu, Chun-miao; Zhong, Jing; Sun, Fei

    2009-06-01

    To assess the reproducibility of whole-body diffusion weighted imaging (WB-DWI) technique in healthy volunteers under normal breathing with background body signal suppression. WB-DWI was performed on 32 healthy volunteers twice within two-week period using short TI inversion-recovery diffusion-weighted echo-planar imaging sequence and built-in body coil. The volunteers were scanned across six stations continuously covering the entire body from the head to the feet under normal breathing. The bone apparent diffusion coefficient (ADC) and exponential ADC (eADC) of regions of interest (ROIs) were measured. We analyzed correlation of the results using paired-t-test to assess the reproducibility of the WB-DWI technique. We were successful in collecting and analyzing data of 64 WB-DWI images. There was no significant difference in bone ADC and eADC of 824 ROIs between the paired observers and paired scans (P>0.05). Most of the images from all stations were of diagnostic quality. The measurements of bone ADC and eADC have good reproducibility. WB-DWI technique under normal breathing with background body signal suppression is adequate.

  15. GRE T2∗-Weighted MRI: Principles and Clinical Applications

    PubMed Central

    Tang, Meng Yue; Chen, Tian Wu; Zhang, Xiao Ming; Huang, Xiao Hua

    2014-01-01

    The sequence of a multiecho gradient recalled echo (GRE) T2*-weighted imaging (T2*WI) is a relatively new magnetic resonance imaging (MRI) technique. In contrast to T2 relaxation, which acquires a spin echo signal, T2* relaxation acquires a gradient echo signal. The sequence of a GRE T2*WI requires high uniformity of the magnetic field. GRE T2*WI can detect the smallest changes in uniformity in the magnetic field and can improve the rate of small lesion detection. In addition, the T2* value can indirectly reflect changes in tissue biochemical components. Moreover, it can be used for the early diagnosis and quantitative diagnosis of some diseases. This paper reviews the principles and clinical applications as well as the advantages and disadvantages of GRE T2*WI. PMID:24987676

  16. Is the Susceptibility Vessel Sign on 3-Tesla Magnetic Resonance T2*-Weighted Imaging a Useful Tool to Predict Recanalization in Intravenous Tissue Plasminogen Activator?

    PubMed

    Yamamoto, N; Satomi, J; Harada, M; Izumi, Y; Nagahiro, S; Kaji, R

    2016-09-01

    The aim of this study was to investigate the independent factors associated with the absence of recanalization approximately 24 h after intravenous administration of tissue-type plasminogen activator (IV TPA). The previous studies have been conducted using 1.5-Tesla (T) magnetic resonance imaging (MRI). We studied whether the characteristics of 3-T MRI findings were useful to predict outcome and recanalization after IV tPA. Patients with internal carotid artery (ICA) or middle cerebral artery (MCA) (horizontal portion, M1; Sylvian portion, M2) occlusion and treated by IV tPA were enrolled. We studied whether the presence of susceptibility vessel sign (SVS) at M1 and low clot burden score on T2*-weighted imaging (T2*-CBS) on 3-T MRI were associated with the absence of recanalization. A total of 49 patients were enrolled (27 men; mean age, 73.9 years). MR angiography obtained approximately 24 h after IV tPA revealed recanalization in 21 (42.9 %) patients. Independent factors associated with the absence of recanalization included ICA or proximal M1 occlusion (odds ratio, 69.6; 95 % confidence interval, 5.05-958.8, p = 0.002). In this study, an independent factor associated with the absence of recanalization may be proximal occlusion of the cerebral arteries rather than SVS in the MCA or low T2*-CBS on 3-T MRI.

  17. Patellar cartilage lesions: comparison of magnetic resonance imaging and T2 relaxation-time mapping.

    PubMed

    Hannila, I; Nieminen, M T; Rauvala, E; Tervonen, O; Ojala, R

    2007-05-01

    To evaluate the detection and the size of focal patellar cartilage lesions in T2 mapping as compared to standard clinical magnetic resonance imaging (MRI) at 1.5T. Fifty-five consecutive clinical patients referred to knee MRI were imaged both with a standard knee MRI protocol (proton-density-weighted sagittal and axial series, T2-weighted sagittal and coronal series, and T1-weighted coronal series) and with an axial multislice multi-echo spin-echo measurement to determine the T2 relaxation time of the patellar cartilage. MR images and T2 maps of patellar cartilage were evaluated for focal lesions. The lesions were evaluated for lesion width (mm), lesion depth (1/3, 2/3, or 3/3 of cartilage thickness), and T2 value (20-40 ms, 40-60 ms, or 60-80 ms) based on visual evaluation. Altogether, 36 focal patellar cartilage lesions were detected from 20 human subjects (11 male, nine female, mean age 40+/-15 years). Twenty-eight lesions were detected both on MRI and T2 maps, while eight lesions were only visible on T2 maps. Cartilage lesions were significantly wider (P = 0.001) and thicker (P<0.001) on T2 maps as compared to standard knee MRI. Most lesions 27 had moderately (T2 40-60 ms) increased T2 values, while two lesions had slightly (T2 20-40 ms) and seven lesions remarkably (T2 60-80 ms) increased T2 relaxation times. T2 mapping of articular cartilage is feasible in the clinical setting and may reveal early cartilage lesions not visible with standard clinical MRI.

  18. Application of Curved MPR Algorithm to High Resolution 3 Dimensional T2 Weighted CISS Images for Virtual Uncoiling of Membranous Cochlea as an Aid for Cochlear Morphometry.

    PubMed

    Kumar, Joish Upendra; Kavitha, Y

    2017-02-01

    With the use of various surgical techniques, types of implants, the preoperative assessment of cochlear dimensions is becoming increasingly relevant prior to cochlear implantation. High resolution CISS protocol MRI gives a better assessment of membranous cochlea, cochlear nerve, and membranous labyrinth. Curved Multiplanar Reconstruction (MPR) algorithm provides better images that can be used for measuring dimensions of membranous cochlea. To ascertain the value of curved multiplanar reconstruction algorithm in high resolution 3-Dimensional T2 Weighted Gradient Echo Constructive Interference Steady State (3D T2W GRE CISS) imaging for accurate morphometry of membranous cochlea. Fourteen children underwent MRI for inner ear assessment. High resolution 3D T2W GRE CISS sequence was used to obtain images of cochlea. Curved MPR reconstruction algorithm was used to virtually uncoil the membranous cochlea on the volume images and cochlear measurements were done. Virtually uncoiled images of membranous cochlea of appropriate resolution were obtained from the volume data obtained from the high resolution 3D T2W GRE CISS images, after using curved MPR reconstruction algorithm mean membranous cochlear length in the children was 27.52 mm. Maximum apical turn diameter of membranous cochlea was 1.13 mm, mid turn diameter was 1.38 mm, basal turn diameter was 1.81 mm. Curved MPR reconstruction algorithm applied to CISS protocol images facilitates in getting appropriate quality images of membranous cochlea for accurate measurements.

  19. High-speed multislice T1 mapping using inversion-recovery echo-planar imaging.

    PubMed

    Ordidge, R J; Gibbs, P; Chapman, B; Stehling, M K; Mansfield, P

    1990-11-01

    Tissue contrast in MR images is a strong function of spin-lattice (T1) and spin-spin (T2) relaxation times. However, the T1 relaxation time is rarely quantified because of the long scan time required to produce an accurate T1 map of the subject. In a standard 2D FT technique, this procedure may take up to 30 min. Modifications of the echo-planar imaging (EPI) technique which incorporate the principle of inversion recovery (IR) enable multislice T1 maps to be produced in total scan times varying from a few seconds up to a minute. Using IR-EPI, rapid quantification of T1 values may thus lead to better discrimination between tissue types in an acceptable scan time.

  20. Prognostic usefulness of derived T2-weighted fetal magnetic resonance imaging measurements in congenital diaphragmatic hernia.

    PubMed

    Sebastià, C; Gomez, O; Salvador, R; Buñesch, L; Garcia, R; Nicolau, C

    2015-01-01

    To determine the usefulness of various parameters based on T2-weighted fetal magnetic resonance (MR) imaging measurements of the uninvolved lung for the neonatal prognosis of congenital diaphragmatic hernia (CDH). We used ultrasonography and MR imaging to study 28 fetuses with CDH. We retrospectively analyzed a) on fetal ultrasonography, the observed-to-expected lung to head ratio (O/E LHR) and the position of the liver, and b) on fetal MR imaging, the lung-liver signal ratio (LLSR) and the lungcerebrospinal fluid ratio (L/CSF SR). To determine the prognostic value of these parameters, we compared them with the following postnatal parameters: survival, pulmonary hypertension, need for oxygen supplementation, and need for extracorporeal membrane oxygenation. We found significant differences between O/E LHR and the need for postnatal extracorporeal membrane oxygenation (P=.033) and postnatal survival (P=.01). We also found significant differences in LLSR between fetuses that survived more than 45 days and those that died within 45 days (1.91 vs. 2.56; P=.039). In fetuses with CDH, the LLSR correlates with postnatal survival and can potentially be used as a prognostic parameter in CDH. Copyright © 2013 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  1. Tuning the relaxation rates of dual-mode T1/T2 nanoparticle contrast agents: a study into the ideal system

    NASA Astrophysics Data System (ADS)

    Keasberry, Natasha A.; Bañobre-López, Manuel; Wood, Christopher; Stasiuk, Graeme. J.; Gallo, Juan; Long, Nicholas. J.

    2015-09-01

    Magnetic resonance imaging (MRI) is an excellent imaging modality. However the low sensitivity of the technique poses a challenge to achieving an accurate image of function at the molecular level. To overcome this, contrast agents are used; typically gadolinium based agents for T1 weighted imaging, or iron oxide based agents for T2 imaging. Traditionally, only one imaging mode is used per diagnosis although several physiological situations are known to interfere with the signal induced by the contrast agents in each individual imaging mode acquisition. Recently, the combination of both T1 and T2 imaging capabilities into a single platform has emerged as a tool to reduce uncertainties in MR image analysis. To date, contradicting reports on the effect on the contrast of the coupling of a T1 and T2 agent have hampered the application of these specialised probes. Herein, we present a systematic experimental study on a range of gadolinium-labelled magnetite nanoparticles envisioned to bring some light into the mechanism of interaction between T1 and T2 components, and advance towards the design of efficient (dual) T1 and T2 MRI probes. Unexpected behaviours observed in some of the constructs will be discussed. In this study, we demonstrate that the relaxivity of such multimodal probes can be rationally tuned to obtain unmatched potentials in MR imaging, exemplified by preparation of the magnetite-based nanoparticle with the highest T2 relaxivity described to date.Magnetic resonance imaging (MRI) is an excellent imaging modality. However the low sensitivity of the technique poses a challenge to achieving an accurate image of function at the molecular level. To overcome this, contrast agents are used; typically gadolinium based agents for T1 weighted imaging, or iron oxide based agents for T2 imaging. Traditionally, only one imaging mode is used per diagnosis although several physiological situations are known to interfere with the signal induced by the contrast agents in

  2. Topographical Variation of Human Femoral Articular Cartilage Thickness, T1rho and T2 Relaxation Times Is Related to Local Loading during Walking.

    PubMed

    Van Rossom, Sam; Wesseling, Mariska; Van Assche, Dieter; Jonkers, Ilse

    2018-01-01

    Objective Early detection of degenerative changes in the cartilage matrix composition is essential for evaluating early interventions that slow down osteoarthritis (OA) initiation. T1rho and T2 relaxation times were found to be effective for detecting early changes in proteoglycan and collagen content. To use these magnetic resonance imaging (MRI) methods, it is important to document the topographical variation in cartilage thickness, T1rho and T2 relaxation times in a healthy population. As OA is partially mechanically driven, the relation between these MRI-based parameters and localized mechanical loading during walking was investigated. Design MR images were acquired in 14 healthy adults and cartilage thickness and T1rho and T2 relaxation times were determined. Experimental gait data was collected and processed using musculoskeletal modeling to identify weight-bearing zones and estimate the contact force impulse during gait. Variation of the cartilage properties (i.e., thickness, T1rho, and T2) over the femoral cartilage was analyzed and compared between the weight-bearing and non-weight-bearing zone of the medial and lateral condyle as well as the trochlea. Results Medial condyle cartilage thickness was correlated to the contact force impulse ( r = 0.78). Lower T1rho, indicating increased proteoglycan content, was found in the medial weight-bearing zone. T2 was higher in all weight-bearing zones compared with the non-weight-bearing zones, indicating lower relative collagen content. Conclusions The current results suggest that medial condyle cartilage is adapted as a long-term protective response to localized loading during a frequently performed task and that the weight-bearing zone of the medial condyle has superior weight bearing capacities compared with the non-weight-bearing zones.

  3. T1-weighted in vivo human whole brain MRI dataset with an ultrahigh isotropic resolution of 250 μm.

    PubMed

    Lüsebrink, Falk; Sciarra, Alessandro; Mattern, Hendrik; Yakupov, Renat; Speck, Oliver

    2017-03-14

    We present an ultrahigh resolution in vivo human brain magnetic resonance imaging (MRI) dataset. It consists of T 1 -weighted whole brain anatomical data acquired at 7 Tesla with a nominal isotropic resolution of 250 μm of a single young healthy Caucasian subject and was recorded using prospective motion correction. The raw data amounts to approximately 1.2 TB and was acquired in eight hours total scan time. The resolution of this dataset is far beyond any previously published in vivo structural whole brain dataset. Its potential use is to build an in vivo MR brain atlas. Methods for image reconstruction and image restoration can be improved as the raw data is made available. Pre-processing and segmentation procedures can possibly be enhanced for high magnetic field strength and ultrahigh resolution data. Furthermore, potential resolution induced changes in quantitative data analysis can be assessed, e.g., cortical thickness or volumetric measures, as high quality images with an isotropic resolution of 1 and 0.5 mm of the same subject are included in the repository as well.

  4. T1-weighted in vivo human whole brain MRI dataset with an ultrahigh isotropic resolution of 250 μm

    NASA Astrophysics Data System (ADS)

    Lüsebrink, Falk; Sciarra, Alessandro; Mattern, Hendrik; Yakupov, Renat; Speck, Oliver

    2017-03-01

    We present an ultrahigh resolution in vivo human brain magnetic resonance imaging (MRI) dataset. It consists of T1-weighted whole brain anatomical data acquired at 7 Tesla with a nominal isotropic resolution of 250 μm of a single young healthy Caucasian subject and was recorded using prospective motion correction. The raw data amounts to approximately 1.2 TB and was acquired in eight hours total scan time. The resolution of this dataset is far beyond any previously published in vivo structural whole brain dataset. Its potential use is to build an in vivo MR brain atlas. Methods for image reconstruction and image restoration can be improved as the raw data is made available. Pre-processing and segmentation procedures can possibly be enhanced for high magnetic field strength and ultrahigh resolution data. Furthermore, potential resolution induced changes in quantitative data analysis can be assessed, e.g., cortical thickness or volumetric measures, as high quality images with an isotropic resolution of 1 and 0.5 mm of the same subject are included in the repository as well.

  5. Quantitative evaluation of ischemic myocardial scar tissue by unenhanced T1 mapping using 3.0 Tesla MR scanner

    PubMed Central

    Okur, Aylin; Kantarcı, Mecit; Kızrak, Yeşim; Yıldız, Sema; Pirimoğlu, Berhan; Karaca, Leyla; Oğul, Hayri; Sevimli, Serdar

    2014-01-01

    PURPOSE We aimed to use a noninvasive method for quantifying T1 values of chronic myocardial infarction scar by cardiac magnetic resonance imaging (MRI), and determine its diagnostic performance. MATERIALS AND METHODS We performed cardiac MRI on 29 consecutive patients with known coronary artery disease (CAD) on 3.0 Tesla MRI scanner. An unenhanced T1 mapping technique was used to calculate T1 relaxation time of myocardial scar tissue, and its diagnostic performance was evaluated. Chronic scar tissue was identified by delayed contrast-enhancement (DE) MRI and T2-weighted images. Sensitivity, specificity, and accuracy values were calculated for T1 mapping using DE images as the gold standard. RESULTS Four hundred and forty-two segments were analyzed in 26 patients. While myocardial chronic scar was demonstrated in 45 segments on DE images, T1 mapping MRI showed a chronic scar area in 54 segments. T1 relaxation time was higher in chronic scar tissue, compared with remote areas (1314±98 ms vs. 1099±90 ms, P < 0.001). Therefore, increased T1 values were shown in areas of myocardium colocalized with areas of DE and normal signal on T2-weighted images. There was a significant correlation between T1 mapping and DE images in evaluation of myocardial wall injury extent (P < 0.05). We calculated sensitivity, specificity, and accuracy as 95.5%, 97%, and 96%, respectively. CONCLUSION The results of the present study reveal that T1 mapping MRI combined with T2-weighted images might be a feasible imaging modality for detecting chronic myocardial infarction scar tissue. PMID:25010366

  6. An automated tool for cortical feature analysis: Application to differences on 7 Tesla T2* -weighted images between young and older healthy subjects.

    PubMed

    Doan, Nhat Trung; van Rooden, Sanneke; Versluis, Maarten J; Buijs, Mathijs; Webb, Andrew G; van der Grond, Jeroen; van Buchem, Mark A; Reiber, Johan H C; Milles, Julien

    2015-07-01

    High field T 2 * -weighted MR images of the cerebral cortex are increasingly used to study tissue susceptibility changes related to aging or pathologies. This paper presents a novel automated method for the computation of quantitative cortical measures and group-wise comparison using 7 Tesla T 2 * -weighted magnitude and phase images. The cerebral cortex was segmented using a combination of T 2 * -weighted magnitude and phase information and subsequently was parcellated based on an anatomical atlas. Local gray matter (GM)/white matter (WM) contrast and cortical profiles, which depict the magnitude or phase variation across the cortex, were computed from the magnitude and phase images in each parcellated region and further used for group-wise comparison. Differences in local GM/WM contrast were assessed using linear regression analysis. Regional cortical profiles were compared both globally and locally using permutation testing. The method was applied to compare a group of 10 young volunteers with a group of 15 older subjects. Using local GM/WM contrast, significant differences were revealed in at least 13 of 17 studied regions. Highly significant differences between cortical profiles were shown in all regions. The proposed method can be a useful tool for studying cortical changes in normal aging and potentially in neurodegenerative diseases. Magn Reson Med 74:240-248, 2015. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  7. Texture Analysis of T1-Weighted and Fluid-Attenuated Inversion Recovery Images Detects Abnormalities That Correlate With Cognitive Decline in Small Vessel Disease.

    PubMed

    Tozer, Daniel J; Zeestraten, Eva; Lawrence, Andrew J; Barrick, Thomas R; Markus, Hugh S

    2018-06-04

    Magnetic resonance imaging may be useful to assess disease severity in cerebral small vessel disease (SVD), identify those individuals who are most likely to progress to dementia, monitor disease progression, and act as surrogate markers to test new therapies. Texture analysis extracts information on the relationship between signal intensities of neighboring voxels. A potential advantage over techniques, such as diffusion tensor imaging, is that it can be used on clinically obtained magnetic resonance sequences. We determined whether texture parameters (TP) were abnormal in SVD, correlated with cognitive impairment, predicted cognitive decline, or conversion to dementia. In the prospective SCANS study (St George's Cognition and Neuroimaging in Stroke), we assessed TP in 121 individuals with symptomatic SVD at baseline, 99 of whom attended annual cognitive testing for 5 years. Conversion to dementia was recorded for all subjects during the 5-year period. Texture analysis was performed on fluid-attenuated inversion recovery and T1-weighted images. The TP obtained from the SVD cohort were cross-sectionally compared with 54 age-matched controls scanned on the same magnetic resonance imaging system. There were highly significant differences in several TP between SVD cases and controls. Within the SVD population, TP were highly correlated to other magnetic resonance imaging parameters (brain volume, white matter lesion volume, lacune count). TP correlated with executive function and global function at baseline and predicted conversion to dementia, after controlling for age, sex, premorbid intelligence quotient, and magnetic resonance parameters. TP, which can be obtained from routine clinical images, are abnormal in SVD, and the degree of abnormality correlates with executive dysfunction and global cognition at baseline and decline during 5 years. TP may be useful to assess disease severity in clinically collected data. This needs testing in data clinically acquired

  8. Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.

    PubMed

    Vos, Eline K; Sambandamurthy, Sriram; Kamel, Maged; McKenney, Robert; van Uden, Mark J; Hoeks, Caroline M A; Yakar, Derya; Scheenen, Tom W J; Fütterer, Jurgen J

    2014-01-01

    The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal coil (ERC) for prostate magnetic resonance imaging at both 1.5 and 3 T. The study was approved by the institutional review board, and written informed consent was obtained from all patients. In total, 8 consecutive patients with prostate cancer underwent a local staging magnetic resonance examination with the successive use of both coils in 1 session (4 patients at 1.5 T and 4 other patients at 3 T). Quantitative comparison of both coils was performed for the apex, mid-gland and base levels at both field strengths by calculating SNR profiles in the axial plane on an imaginary line in the anteroposterior direction perpendicular to the coil surface. Two radiologists independently assessed the image quality of the T2-weighted and apparent diffusion coefficient maps calculated from diffusion-weighted imaging using a 5-point scale. Improvement of geometric distortion on diffusion-weighted imaging with the use of parallel imaging was explored. Statistical analysis included a paired Wilcoxon signed rank test for SNR and image quality evaluation as well as κ statistics for interobserver agreement. No adverse events were reported. The SNR was higher for the NG-ERC compared with the ERC up to a distance of approximately 40 mm from the surface of the coil at 1.5 T (P < 0.0001 for the apex, the mid-gland, and the base) and approximately 17 mm (P = 0.015 at the apex level) and 30 mm at 3 T (P < 0.0001 for the mid-gland and base). Beyond this distance, the SNR profiles of both coils were comparable. Overall, T2-weighted image quality was considered better for NG-ERC at both field strengths. Quality of apparent diffusion coefficient maps with the use of parallel imaging was

  9. Closed-form expressions for flip angle variation that maximize total signal in T1-weighted rapid gradient echo MRI.

    PubMed

    Drobnitzky, Matthias; Klose, Uwe

    2017-03-01

    Magnetization-prepared rapid gradient-echo (MPRAGE) sequences are commonly employed for T1-weighted structural brain imaging. Following a contrast preparation radiofrequency (RF) pulse, the data acquisition proceeds under nonequilibrium conditions of the relaxing longitudinal magnetization. Variation of the flip angle can be used to maximize total available signal. Simulated annealing or greedy algorithms have so far been published to numerically solve this problem, with signal-to-noise ratios optimized for clinical imaging scenarios by adhering to a predefined shape of the signal evolution. We propose an unconstrained optimization of the MPRAGE experiment that employs techniques from resource allocation theory. A new dynamic programming solution is introduced that yields closed-form expressions for optimal flip angle variation. Flip angle series are proposed that maximize total transverse magnetization (Mxy) for a range of physiologic T1 values. A 3D MPRAGE sequence is modified to allow for a controlled variation of the excitation angle. Experiments employing a T1 contrast phantom are performed at 3T. 1D acquisitions without phase encoding permit measurement of the temporal development of Mxy. Image mean signal and standard deviation for reference flip angle trains are compared in 2D measurements. Signal profiles at sharp phantom edges are acquired to access image blurring related to nonuniform Mxy development. A novel closed-form expression for flip angle variation is found that constitutes the optimal policy to reach maximum total signal. It numerically equals previously published results of other authors when evaluated under their simplifying assumptions. Longitudinal magnetization (Mz) is exhaustively used without causing abrupt changes in the measured MR signal, which is a prerequisite for artifact free images. Phantom experiments at 3T verify the expected benefit for total accumulated k-space signal when compared with published flip angle series. Describing

  10. Magnetic resonance imaging protocols for examination of the neurocranium at 3 T.

    PubMed

    Schwindt, W; Kugel, H; Bachmann, R; Kloska, S; Allkemper, T; Maintz, D; Pfleiderer, B; Tombach, B; Heindel, W

    2003-09-01

    The increasing availability of high-field (3 T) MR scanners requires adapting and optimizing clinical imaging protocols to exploit the theoretically higher signal-to-noise ratio (SNR) of the higher field strength. Our aim was to establish reliable and stable protocols meeting the clinical demands for imaging the neurocranium at 3 T. Two hundred patients with a broad range of indications received an examination of the neurocranium with an appropriate assortment of imaging techniques at 3 T. Several imaging parameters were optimized. Keeping scan times comparable to those at 1.5 T we increased spatial resolution. Contrast-enhanced and non-enhanced T1-weighted imaging was best applying gradient-echo and inversion recovery (rather than spin-echo) techniques, respectively. For fluid-attenuated inversion recovery (FLAIR) imaging a TE of 120 ms yielded optimum contrast-to-noise ratio (CNR). High-resolution isotropic 3D data sets were acquired within reasonable scan times. Some artifacts were pronounced, but generally imaging profited from the higher SNR. We present a set of optimized examination protocols for neuroimaging at 3 T, which proved to be reliable in a clinical routine setting.

  11. Evaluation of grades 3 and 4 chondromalacia of the knee using T2*-weighted 3D gradient-echo articular cartilage imaging.

    PubMed

    Murphy, B J

    2001-06-01

    To determine the accuracy of T2*-weighted three-dimensional (3D) gradient-echo articular cartilage imaging in the identification of grades 3 and 4 chondromalacia of the knee. A retrospective evaluation of 80 patients who underwent both arthroscopic and MRI evaluation was performed. The 3D images were interpreted by one observer without knowledge of the surgical results. The medial and lateral femoral condyles, the medial and lateral tibial plateau, the patellar cartilage and trochlear groove were evaluated. MR cartilage images were considered positive if focal reduction of cartilage thickness was present (grade 3 chondromalacia) or if complete loss of cartilage was present (grade 4 chondromalacia). Comparison of the 3D MR results with the arthroscopic findings was performed. Eighty patients were included in the study group. A total of 480 articular cartilage sites were evaluated with MRI and arthroscopy. Results of MR identification of grades 3 and 4 chondromalacia, all sites combined, were: sensitivity 83%, specificity 97%, false negative rate 17%, false positive rate 3%, positive predictive value 87%, negative predictive value 95%, overall accuracy 93%. The results demonstrate that T2*-weighted 3D gradient-echo articular cartilage imaging can identify grades 3 and 4 chondromalacia of the knee.

  12. A highly stable l-alanine-based mono(aquated) Mn(ii) complex as a T1-weighted MRI contrast agent.

    PubMed

    Khannam, Mahmuda; Weyhermüller, Thomas; Goswami, Upashi; Mukherjee, Chandan

    2017-08-08

    The synthesized lithium (S)-6,6'-(1-carboxyethylazanediyl)bis(methylene)dipicolinate (Li 3 cbda) is a new chiral, alanine-based ligand bearing two picolinate functionalities. The trianionic form of the ligand [(cbda) 3- ] constitutes a seven-coordinate, water-soluble, pentagonal bipyramidal Mn(ii) complex (1). The structural analysis reveals the presence of a water coordinating site in the complex. The complex is thermodynamically very stable, and the stability is not affected by the presence of physiological anions (HCO 3 - , PO 4 3- , and F - ). The pH of the medium exerts a small effect on the stability of the complex. The r 1 relaxivity of 3.02 mM -1 s -1 is exhibited by the complex at 1.41 T, pH ∼7.4, and 25 °C. Phantom images obtained via a clinical MRI BRIVO MR355 system established concentration-dependent signal enhancement by the complex. The cytotoxicity test confirmed complex 1 as a biocompatible potential T 1 -weighted MRI contrast agent.

  13. T1ρ MRI Quantification of Arthroscopically-Confirmed Cartilage Degeneration

    PubMed Central

    Witschey, Walter RT; Borthakur, Arijitt; Fenty, Matt; Kneeland, J Bruce; Lonner, Jess H; McArdle, Erin L.; Sochor, Matt; Reddy, Ravinder

    2010-01-01

    9 asymptomatic subjects and 6 patients underwent T1ρ MRI to determine whether Outerbridge grade 1 or 2 cartilage degeneration observed during arthroscopy could be detected noninvasively. MRI was performed 2–3 months post-arthroscopy using sagittal T1-weighted and axial and coronal T1ρ MRI from which spatial T1ρ relaxation maps were calculated from segmented T1-weighted images. Median T1ρ relaxation times of patients with arthroscopically documented cartilage degeneration and asymptomatic subjects were significantly different (p < 0.001) and median T1ρ exceeded asymptomatic articular cartilage median T1ρ by 2.5 to 9.2 ms. In 8 observations of mild cartilage degeneration at arthroscopy (Outerbridge grades 1 and 2), mean compartment T1ρ was elevated in 5, but in all observations, large foci of increased T1ρ were observed. It was determined that T1ρ could detect some, but not all, Outerbridge grade 1 and 2 cartilage degeneration but that a larger patient population is needed to determine the sensitivity to these changes. PMID:20432308

  14. Breast MRI at Very Short TE (minTE): Image Analysis of minTE Sequences on Non-Fat-Saturated, Subtracted T1-Weighted Images.

    PubMed

    Wenkel, Evelyn; Janka, Rolf; Geppert, Christian; Kaemmerer, Nadine; Hartmann, Arndt; Uder, Michael; Hammon, Matthias; Brand, Michael

    2017-02-01

    temporal resolution for a better in-flow curve.. · Dynamic breast MRI with a shorter TE time is possible without relevant loss of information.. · Possible decrease of the overall scan time.. Citation Format · Wenkel E, Janka R, Geppert C et al. Breast MRI at Very Short TE (minTE): Image Analysis of minTE Sequences on Non-Fat-Saturated, Subtracted T1-Weighted Images. Fortschr Röntgenstr 2017; 189: 137 - 145. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Gas-induced susceptibility artefacts on diffusion-weighted MRI of the rectum at 1.5 T - Effect of applying a micro-enema to improve image quality.

    PubMed

    van Griethuysen, Joost J M; Bus, Elyse M; Hauptmann, Michael; Lahaye, Max J; Maas, Monique; Ter Beek, Leon C; Beets, Geerard L; Bakers, Frans C H; Beets-Tan, Regina G H; Lambregts, Doenja M J

    2018-02-01

    Assess whether application of a micro-enema can reduce gas-induced susceptibility artefacts in Single-shot Echo Planar Imaging (EPI) Diffusion-weighted imaging of the rectum at 1.5 T. Retrospective analysis of n = 50 rectal cancer patients who each underwent multiple DWI-MRIs (1.5 T) from 2012 to 2016 as part of routine follow-up during a watch-and-wait approach after chemoradiotherapy. From March 2014 DWI-MRIs were routinely acquired after application of a preparatory micro-enema (Microlax ® ; 5 ml; self-administered shortly before acquisition); before March 2014 no bowel preparation was given. In total, 335 scans were scored by an experienced reader for the presence/severity of gas-artefacts (on b1000 DWI), ranging from 0 (no artefact) to 5 (severe artefact). A score ≥3 (moderate-severe) was considered a clinically relevant artefact. A random sample of 100 scans was re-assessed by a second independent reader to study inter-observer effects. Scores were compared between the scans performed without and with a preparatory micro-enema using univariable and multivariable logistic regression taking into account potential confounding factors (age/gender, acquisition parameters, MRI-hardware, rectoscopy prior to MRI). Clinically relevant gas-artefacts were seen in 24.3% (no micro-enema) vs. 3.7% (micro-enema), odds ratios were 0.118 in univariable and 0.230 in multivariable regression (P = 0.0005 and 0.0291). Mean severity score (±SD) was 1.19 ± 1.71 (no-enema) vs 0.32 ± 0.77 (micro-enema), odds ratios were 0.321 (P < 0.0001) and 0.489 (P = 0.0461) in uni- and multivariable regression, respectively. Inter-observer agreement was excellent (κ0.85). Use of a preparatory micro-enema shortly before rectal EPI-DWI examinations performed at 1.5 T MRI significantly reduces both the incidence and severity of gas-induced artefacts, compared to examinations performed without bowel preparation. Copyright © 2017 Elsevier B.V. All rights

  16. MR imaging detection of cerebral microbleeds: effect of susceptibility-weighted imaging, section thickness, and field strength.

    PubMed

    Nandigam, R N K; Viswanathan, A; Delgado, P; Skehan, M E; Smith, E E; Rosand, J; Greenberg, S M; Dickerson, B C

    2009-02-01

    The emergence of cerebral microbleeds (CMB) as common MR imaging findings raises the question of how MR imaging parameters influence CMB detection. To evaluate the effects of modified gradient recalled-echo (GRE) MR imaging methods, we performed an analysis of sequence, section thickness, and field strength on CMB imaging properties and detection in subjects with cerebral amyloid angiopathy (CAA), a condition associated with microhemorrhage. Multiple MR images were obtained from subjects with probable CAA, with varying sequences (GRE versus susceptibility-weighted imaging [SWI]), section thicknesses (1.2-1.5 versus 5 mm), and magnetic field strengths (1.5T versus 3T). Individual CMB were manually identified and analyzed for contrast index (lesion intensity normalized to normal-appearing white matter signal intensity) and diameter. CMB counts were compared between 1.5T thick-section GRE and thin-section SWI for 3 subjects who underwent both protocols in the same scanning session. With other parameters constant, use of SWI, thinner sections, and a higher field strength yielded medium-to-large gains in CMB contrast index (CI; Cohen d 0.71-1.87). SWI was also associated with small increases in CMB diameter (Cohen d <0.3). Conventional thick-section GRE identified only 33% of CMB (103 of 310) seen on thin-section SWI. Lesions prospectively identified on GRE had significantly greater CI and diameter measured on the GRE image than those not prospectively identified. The examined alternatives to conventional GRE MR imaging yield substantially improved CMB contrast and sensitivity for detection. Future studies based on these techniques will most likely yield even higher prevalence estimates for CMB.

  17. MR Imaging Detection of Cerebral Microbleeds: Effect of Susceptibility-Weighted Imaging, Section Thickness, and Field Strength

    PubMed Central

    Nandigam, R.N.K.; Viswanathan, A.; Delgado, P.; Skehan, M.E.; Smith, E.E.; Rosand, J.; Greenberg, S.M.; Dickerson, B.C.

    2009-01-01

    BACKGROUND AND PURPOSE: The emergence of cerebral microbleeds (CMB) as common MR imaging findings raises the question of how MR imaging parameters influence CMB detection. To evaluate the effects of modified gradient recalled-echo (GRE) MR imaging methods, we performed an analysis of sequence, section thickness, and field strength on CMB imaging properties and detection in subjects with cerebral amyloid angiopathy (CAA), a condition associated with microhemorrhage. MATERIALS AND METHODS: Multiple MR images were obtained from subjects with probable CAA, with varying sequences (GRE versus susceptibility-weighted imaging [SWI]), section thicknesses (1.2–1.5 versus 5 mm), and magnetic field strengths (1.5T versus 3T). Individual CMB were manually identified and analyzed for contrast index (lesion intensity normalized to normal-appearing white matter signal intensity) and diameter. CMB counts were compared between 1.5T thick-section GRE and thin-section SWI for 3 subjects who underwent both protocols in the same scanning session. RESULTS: With other parameters constant, use of SWI, thinner sections, and a higher field strength yielded medium-to-large gains in CMB contrast index (CI; Cohen d 0.71–1.87). SWI was also associated with small increases in CMB diameter (Cohen d <0.3). Conventional thick-section GRE identified only 33% of CMB (103 of 310) seen on thin-section SWI. Lesions prospectively identified on GRE had significantly greater CI and diameter measured on the GRE image than those not prospectively identified. CONCLUSIONS: The examined alternatives to conventional GRE MR imaging yield substantially improved CMB contrast and sensitivity for detection. Future studies based on these techniques will most likely yield even higher prevalence estimates for CMB. PMID:19001544

  18. 3D segmentation of annulus fibrosus and nucleus pulposus from T2-weighted magnetic resonance images

    NASA Astrophysics Data System (ADS)

    Castro-Mateos, Isaac; Pozo, Jose M.; Eltes, Peter E.; Del Rio, Luis; Lazary, Aron; Frangi, Alejandro F.

    2014-12-01

    Computational medicine aims at employing personalised computational models in diagnosis and treatment planning. The use of such models to help physicians in finding the best treatment for low back pain (LBP) is becoming popular. One of the challenges of creating such models is to derive patient-specific anatomical and tissue models of the lumbar intervertebral discs (IVDs), as a prior step. This article presents a segmentation scheme that obtains accurate results irrespective of the degree of IVD degeneration, including pathological discs with protrusion or herniation. The segmentation algorithm, employing a novel feature selector, iteratively deforms an initial shape, which is projected into a statistical shape model space at first and then, into a B-Spline space to improve accuracy. The method was tested on a MR dataset of 59 patients suffering from LBP. The images follow a standard T2-weighted protocol in coronal and sagittal acquisitions. These two image volumes were fused in order to overcome large inter-slice spacing. The agreement between expert-delineated structures, used here as gold-standard, and our automatic segmentation was evaluated using Dice Similarity Index and surface-to-surface distances, obtaining a mean error of 0.68 mm in the annulus segmentation and 1.88 mm in the nucleus, which are the best results with respect to the image resolution in the current literature.

  19. Value of 3.0 T MR imaging in refractory partial epilepsy and negative 1.5 T MRI.

    PubMed

    Nguyen, Dang Khoa; Rochette, Emilie; Leroux, Jean-Maxime; Beaudoin, Gilles; Cossette, Patrick; Lassonde, Maryse; Guilbert, François

    2010-10-01

    High-field 3.0 T MR scanners provide an improved signal-to-noise ratio which can be translated in higher image resolution, possibly allowing critical detection of subtle epileptogenic lesions missed on standard-field 1.0-1.5 T MRIs. In this study, the authors explore the potential value of re-imaging at 3.0 T patients with refractory partial epilepsy and negative 1.5 T MRI. We retrospectively identified all patients with refractory partial epilepsy candidate for surgery who had undergone a 3.0 T MR study after a negative 1.5 T MR study. High-field 3.0 T MRIs were reviewed qualitatively by neuroradiologists experienced in interpreting epilepsy studies with access to clinical information. Relevance and impact on clinical management were assessed by an epileptologist. Between November 2006 and August 2009, 36 patients with refractory partial epilepsy candidate for surgery underwent 3.0 T MR study after a 1.5 T MR study failed to disclose a relevant epileptogenic lesion. A potential lesion was found only in two patients (5.6%, 95% CI: 1.5-18.1%). Both were found to have hippocampal atrophy congruent with other presurgical localization techniques which resulted in omission of an invasive EEG study and direct passage to surgery. The frequency of detection of a new lesion by re-imaging at 3.0 T patients with refractory partial epilepsy candidate for surgery was found to be low, but seems to offer the potential of a significant clinical impact for selected patients. This finding needs to be validated in a prospective controlled study. Copyright © 2010 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  20. Quantitative and qualitative comparison of MR imaging of the temporomandibular joint at 1.5 and 3.0 T using an optimized high-resolution protocol.

    PubMed

    Manoliu, Andrei; Spinner, Georg; Wyss, Michael; Erni, Stefan; Ettlin, Dominik A; Nanz, Daniel; Ulbrich, Erika J; Gallo, Luigi M; Andreisek, Gustav

    2016-01-01

    To quantitatively and qualitatively compare MRI of the temporomandibular joint (TMJ) using an optimized high-resolution protocol at 3.0 T and a clinical standard protocol at 1.5 T. A phantom and 12 asymptomatic volunteers were MR imaged using a 2-channel surface coil (standard TMJ coil) at 1.5 and 3.0 T (Philips Achieva and Philips Ingenia, respectively; Philips Healthcare, Best, Netherlands). Imaging protocol consisted of coronal and oblique sagittal proton density-weighted turbo spin echo sequences. For quantitative evaluation, a spherical phantom was imaged. Signal-to-noise ratio (SNR) maps were calculated on a voxelwise basis. For qualitative evaluation, all volunteers underwent MRI of the TMJ with the jaw in closed position. Two readers independently assessed visibility and delineation of anatomical structures of the TMJ and overall image quality on a 5-point Likert scale. Quantitative and qualitative measurements were compared between field strengths. The quantitative analysis showed similar SNR for the high-resolution protocol at 3.0 T compared with the clinical protocol at 1.5 T. The qualitative analysis showed significantly better visibility and delineation of clinically relevant anatomical structures of the TMJ, including the TMJ disc and pterygoid muscle as well as better overall image quality at 3.0 T than at 1.5 T. The presented results indicate that expected gains in SNR at 3.0 T can be used to increase the spatial resolution when imaging the TMJ, which translates into increased visibility and delineation of anatomical structures of the TMJ. Therefore, imaging at 3.0 T should be preferred over 1.5 T for imaging the TMJ.

  1. Defining intrahepatic biliary anatomy in living liver transplant donor candidates at mangafodipir trisodium-enhanced MR cholangiography versus conventional T2-weighted MR cholangiography.

    PubMed

    Lee, Vivian S; Krinsky, Glenn A; Nazzaro, Carol A; Chang, Jerry S; Babb, James S; Lin, Jennifer C; Morgan, Glyn R; Teperman, Lewis W

    2004-12-01

    To compare three-dimensional (3D) mangafodipir trisodium-enhanced T1-weighted magnetic resonance (MR) cholangiography with conventional T2-weighted MR cholangiography for depiction and definition of intrahepatic biliary anatomy in liver transplant donor candidates. One hundred eight healthy liver transplant donor candidates were examined with two MR cholangiographic methods. All candidates gave written informed consent, and the study was approved by the institutional review board. First, breath-hold transverse and coronal half-Fourier single-shot turbo spin-echo and breath-hold oblique coronal heavily T2-weighted turbo spin-echo sequences were performed. Second, mangafodipir trisodium-enhanced breath-hold fat-suppressed 3D gradient-echo sequences were performed through the ducts (oblique coronal plane) and through the entire liver (transverse plane). Interpretation of biliary anatomy findings, particularly variants affecting right liver lobe biliary drainage, and degree of interpretation confidence at both 3D mangafodipir trisodium-enhanced MR cholangiography and T2-weighted MR cholangiography were recorded and compared by using the Wilcoxon signed rank test. Then, consensus interpretations of both MR image sets together were performed. Intraoperative cholangiography was the reference-standard examination for 51 subjects who underwent right lobe hepatectomy. The McNemar test was used to compare the accuracies of the individual MR techniques with that of the consensus interpretation of both image sets together and to compare each technique with intraoperative cholangiography. Biliary anatomy was visualized with mangafodipir trisodium enhancement in all patients. Mangafodipir trisodium-enhanced image findings agreed with findings seen at combined interpretations significantly more often than did T2-weighted image findings (in 107 [99%] vs 88 [82%] of 108 donor candidates, P < .001). Confidence was significantly higher with the mangafodipir trisodium-enhanced images

  2. Indeterminate orbital masses: restricted diffusion at MR imaging with echo-planar diffusion-weighted imaging predicts malignancy.

    PubMed

    Sepahdari, Ali R; Aakalu, Vinay K; Setabutr, Pete; Shiehmorteza, Masoud; Naheedy, John H; Mafee, Mahmood F

    2010-08-01

    To determine whether magnetic resonance (MR) imaging with diffusion-weighted (DW) imaging can help discriminate between radiologically indeterminate benign and malignant orbital masses and to identify optimal apparent diffusion coefficient (ADC) thresholds for such discrimination. Informed consent was waived for this HIPAA-compliant institutional review board-approved retrospective study. Forty-seven orbital masses imaged with echo-planar DW imaging were identified in 47 patients (25 female patients, 22 male patients; average age, 35 years). A fellowship-trained orbital surgeon determined reference-standard diagnoses on the basis of chart review, and a neuroradiology fellow and senior neuroradiologist who were blinded to the diagnoses selected a region of interest for each lesion by consensus. ADC was calculated from signal intensity on DW images obtained with b = 1000 and b = 0 sec/mm(2). Lesion ADC was also compared with that of normal-appearing white matter (ADC ratio). The Student t test was used to compare groups. Receiver operating characteristic analysis was performed. Intraobserver agreement was assessed with a repeat data collection. Malignant lesions had lower ADCs than benign lesions, irrespective of patient age (P < .02) and in adults specifically (P < .05). Lymphomas had lower ADCs than pseudotumors (P < .001). An ADC of less than 1.0 x 10(-3) mm(2)/sec and an ADC ratio of less than 1.2 were optimal for predicting malignancy (sensitivity, 63% for both; specificity, 84% and 90%, respectively; and accuracy, 77% and 81%, respectively). Lymphoma was differentiated from pseudotumor with 100% accuracy (in 16 of 16 cases) by using these values. Infiltrative lesions that were hypointense on T2-weighted images were better characterized with DW imaging than lesions that were hyperintense or well defined. Echo-planar DW MR imaging can help characterize indeterminate orbital masses.

  3. Pre-treatment functional MRI of breast cancer: T2* evaluation at 3 T and relationship to dynamic contrast-enhanced and diffusion-weighted imaging.

    PubMed

    Kousi, Evanthia; O'Flynn, Elizabeth A M; Borri, Marco; Morgan, Veronica A; deSouza, Nandita M; Schmidt, Maria A

    2018-05-31

    Baseline T2* relaxation time has been proposed as an imaging biomarker in cancer, in addition to Dynamic Contrast-Enhanced (DCE) MRI and diffusion-weighted imaging (DWI) parameters. The purpose of the current work is to investigate sources of error in T2* measurements and the relationship between T2* and DCE and DWI functional parameters in breast cancer. Five female volunteers and thirty-two women with biopsy proven breast cancer were scanned at 3 T, with Research Ethics Committee approval. T2* values of the normal breast were acquired from high-resolution, low-resolution and fat-suppressed gradient-echo sequences in volunteers, and compared. In breast cancer patients, pre-treatment T2*, DCE MRI and DWI were performed at baseline. Pathologically complete responders at surgery and non-responders were identified and compared. Principal component analysis (PCA) and cluster analysis (CA) were performed. There were no significant differences between T2* values from high-resolution, low-resolution and fat-suppressed datasets (p > 0.05). There were not significant differences between baseline functional parameters in responders and non-responders (p > 0.05). However, there were differences in the relationship between T2* and contrast-agent uptake in responders and non-responders. Voxels of similar characteristics were grouped in 5 clusters, and large intra-tumoural variations of all parameters were demonstrated. Breast T2* measurements at 3 T are robust, but spatial resolution should be carefully considered. T2* of breast tumours at baseline is unrelated to DCE and DWI parameters and contribute towards describing functional heterogeneity of breast tumours. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Imaging the Vessel Wall in Major Peripheral Arteries using Susceptibility Weighted Imaging

    PubMed Central

    Yang, Qi; Liu, Jiantao; Barnes, Samuel R.S.; Wu, Zhen; Li, Kuncheng; Neelavalli, Jaladhar; Hu, Jiani; Haacke, E. Mark

    2009-01-01

    Purpose To demonstrate a novel contrast mechanism for imaging the vessel wall and vessel wall calcification using susceptibility weighted imaging (SWI). Materials and Methods 18 subjects were imaged with multi-detector computed tomography (MDCT) and high resolution SWI at 3T. The SWI imaging parameters were optimized to allow for the best visualization of the femoral artery lumen and the arterial wall in magnitude and phase images, respectively. SWI filtered phase data were used to evaluate the diamagnetic susceptibility of vessel wall and of putative vessel wall calcification. Imaging was performed using TE = 15.6 ms (in-phase for fat); TR = 25 ms, FA = 10°, BW = 80 Hz/pixel, resolution = 0.5mm ×0.5mm in-plane and 1.0mm through-plane, an acquisition matrix of 512 × 384 × 64 (for read, phase and slice-select directions) and a total scan time of 8 minutes. Results Nineteen calcifications were identified in CT and SWI and they correlated well in both size and position. The contrast-to-noise ratio between the blood signal in the lumen of the artery and arterial wall was 11.7:1 and 7.4:1 in magnitude and in phase images, respectively. Conclusion SWI provides a novel means to visualize vessel wall and recognize the presence of calcification. PMID:19629989

  5. Quantitative and qualitative comparison of MR imaging of the temporomandibular joint at 1.5 and 3.0 T using an optimized high-resolution protocol

    PubMed Central

    Spinner, Georg; Wyss, Michael; Erni, Stefan; Ettlin, Dominik A; Nanz, Daniel; Ulbrich, Erika J; Gallo, Luigi M; Andreisek, Gustav

    2016-01-01

    Objectives: To quantitatively and qualitatively compare MRI of the temporomandibular joint (TMJ) using an optimized high-resolution protocol at 3.0 T and a clinical standard protocol at 1.5 T. Methods: A phantom and 12 asymptomatic volunteers were MR imaged using a 2-channel surface coil (standard TMJ coil) at 1.5 and 3.0 T (Philips Achieva and Philips Ingenia, respectively; Philips Healthcare, Best, Netherlands). Imaging protocol consisted of coronal and oblique sagittal proton density-weighted turbo spin echo sequences. For quantitative evaluation, a spherical phantom was imaged. Signal-to-noise ratio (SNR) maps were calculated on a voxelwise basis. For qualitative evaluation, all volunteers underwent MRI of the TMJ with the jaw in closed position. Two readers independently assessed visibility and delineation of anatomical structures of the TMJ and overall image quality on a 5-point Likert scale. Quantitative and qualitative measurements were compared between field strengths. Results: The quantitative analysis showed similar SNR for the high-resolution protocol at 3.0 T compared with the clinical protocol at 1.5 T. The qualitative analysis showed significantly better visibility and delineation of clinically relevant anatomical structures of the TMJ, including the TMJ disc and pterygoid muscle as well as better overall image quality at 3.0 T than at 1.5 T. Conclusions: The presented results indicate that expected gains in SNR at 3.0 T can be used to increase the spatial resolution when imaging the TMJ, which translates into increased visibility and delineation of anatomical structures of the TMJ. Therefore, imaging at 3.0 T should be preferred over 1.5 T for imaging the TMJ. PMID:26371077

  6. Pilot Study of the Use of Hybrid Multidimensional T2-Weighted Imaging-DWI for the Diagnosis of Prostate Cancer and Evaluation of Gleason Score.

    PubMed

    Sadinski, Meredith; Karczmar, Gregory; Peng, Yahui; Wang, Shiyang; Jiang, Yulei; Medved, Milica; Yousuf, Ambereen; Antic, Tatjana; Oto, Aytekin

    2016-09-01

    The objective of our study was to evaluate the role of a hybrid T2-weighted imaging-DWI sequence for prostate cancer diagnosis and differentiation of aggressive prostate cancer from nonaggressive prostate cancer. Twenty-one patients with prostate cancer who underwent preoperative 3-T MRI and prostatectomy were included in this study. Patients underwent a hybrid T2-weighted imaging-DWI examination consisting of DW images acquired with TEs of 47, 75, and 100 ms and b values of 0 and 750 s/mm(2). The apparent diffusion coefficient (ADC) and T2 were calculated for cancer and normal prostate ROIs at each TE and b value. Changes in ADC and T2 as a function of increasing the TE and b value, respectively, were analyzed. A new metric termed "PQ4" was defined as the percentage of voxels within an ROI that has increasing T2 with increasing b value and has decreasing ADC with increasing TE. ADC values were significantly higher in normal ROIs than in cancer ROIs at all TEs (p < 0.0001). With increasing TE, the mean ADC increased 3% in cancer ROIs and increased 12% in normal ROIs. T2 was significantly higher in normal ROIs than in cancer ROIs at both b values (p ≤ 0.0002). The mean T2 decreased with increasing b value in cancer ROIs (ΔT2 = -17 ms) and normal ROIs (ΔT2 = -52 ms). PQ4 clearly differentiated normal ROIs from prostate cancer ROIs (p = 0.0004) and showed significant correlation with Gleason score (ρ = 0.508, p < 0.0001). Hybrid MRI measures the response of ADC and T2 to changing TEs and b values, respectively. This approach shows promise for detecting prostate cancer and determining its aggressiveness noninvasively.

  7. Susceptibility-Weighted Phase Imaging and Oxygen Extraction Fraction Measurement during Sedation and Sedation Recovery using 7T MRI.

    PubMed

    Goodwin, Jonathan A; Kudo, Kohsuke; Shinohe, Yutaka; Higuchi, Satomi; Uwano, Ikuko; Yamashita, Fumio; Sasaki, Makoto

    2015-01-01

    In this work, we demonstrate oxygen extraction fraction (OEF) measurement using 7T MRI with susceptibility-weighted imaging (SWI), in sedated and nonsedated adults. Ten healthy subjects (30.3 ± 4.5 years, 9 men, 1 woman) formed control (n = 5) and sedation groups (n = 5). Midazolam and propofol injection was administered to the same sedation group subjects during 2 different scanning sessions. Two-dimensional SPGR imaging was performed before, during, and twice after (propofol, +10, +30 minutes; midazolam, +10, +40 minutes) conscious sedation. The equivalent procedure was performed with the control group without sedation. After SWI analysis, change in OEF between scans was quantified, and parcelated ΔOEF maps were generated with 77 gray matter (GM)-containing volumes-of-interest (VOIs). Significant decreases in OEF were shown in 14 GM VOIs during sedation relative to the control group, most notably during midazolam sedation (P < .05). In contrast, no significant decrease was observed after 10 minutes and in only 4 VOIs after 40 minutes recovery. Significant change in ΔOEF during conscious sedation using midazolam and propofol could be measured using SWI at 7T in vivo. This may be a potentially useful approach for the noninvasive assessment of OEF in the brain on a clinical basis. Copyright © 2014 by the American Society of Neuroimaging.

  8. Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study.

    PubMed

    Hussain, Shahid M; De Becker, Jan; Hop, Wim C J; Dwarkasing, Soendersing; Wielopolski, Piotr A

    2005-03-01

    To optimize and assess the feasibility of a single-shot black-blood T2-weighted spin-echo echo-planar imaging (SSBB-EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2-weighted turbo spin-echo (TSE) sequence. Six volunteers and 16 patients were scanned at 1.5T (Philips Intera). In the volunteer study, we optimized the SSBB-EPI sequence by interactively changing the parameters (i.e., the resolution, echo time (TE), diffusion weighting with low b-values, and polarity of the phase-encoding gradient) with regard to distortion, suppression of the blood signal, and sensitivity to motion. The influence of each change was assessed. The optimized SSBB-EPI sequence was applied in patients (N = 16). A number of items, including the overall image quality (on a scale of 1-5), were used for graded evaluation. In addition, the signal-to-noise ratio (SNR) of the liver was calculated. Statistical analysis was carried out with the use of Wilcoxon's signed rank test for comparison of the SSBB-EPI and TSE sequences, with P = 0.05 considered the limit for significance. The SSBB-EPI sequence was improved by the following steps: 1) less frequency points than phase-encoding steps, 2) a b-factor of 20, and 3) a reversed polarity of the phase-encoding gradient. In patients, the mean overall image quality score for the optimized SSBB-EPI (3.5 (range: 1-4)) and TSE (3.6 (range: 3-4)), and the SNR of the liver on SSBB-EPI (mean +/- SD = 7.6 +/- 4.0) and TSE (8.9 +/- 4.6) were not significantly different (P > .05). Optimized SSBB-EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory-triggered T2-weighted TSE sequence. (c) 2005 Wiley-Liss, Inc.

  9. Resource atlases for multi-atlas brain segmentations with multiple ontology levels based on T1-weighted MRI.

    PubMed

    Wu, Dan; Ma, Ting; Ceritoglu, Can; Li, Yue; Chotiyanonta, Jill; Hou, Zhipeng; Hsu, John; Xu, Xin; Brown, Timothy; Miller, Michael I; Mori, Susumu

    2016-01-15

    Technologies for multi-atlas brain segmentation of T1-weighted MRI images have rapidly progressed in recent years, with highly promising results. This approach, however, relies on a large number of atlases with accurate and consistent structural identifications. Here, we introduce our atlas inventories (n=90), which cover ages 4-82years with unique hierarchical structural definitions (286 structures at the finest level). This multi-atlas library resource provides the flexibility to choose appropriate atlases for various studies with different age ranges and structure-definition criteria. In this paper, we describe the details of the atlas resources and demonstrate the improved accuracy achievable with a dynamic age-matching approach, in which atlases that most closely match the subject's age are dynamically selected. The advanced atlas creation strategy, together with atlas pre-selection principles, is expected to support the further development of multi-atlas image segmentation. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Water-dispersible magnetic carbon nanotubes as T2-weighted MRI contrast agents.

    PubMed

    Liu, Yue; Hughes, Timothy C; Muir, Benjamin W; Waddington, Lynne J; Gengenbach, Thomas R; Easton, Christopher D; Hinton, Tracey M; Moffat, Bradford A; Hao, Xiaojuan; Qiu, Jieshan

    2014-01-01

    An efficient MRI T2-weighted contrast agent incorporating a potential liver targeting functionality was synthesized via the combination of superparamagnetic iron oxide (SPIO) nanoparticles with multiwalled carbon nanotubes (MWCNTs). Poly(diallyldimethylammonium chloride) (PDDA) was coated on the surface of acid treated MWCNTs via electrostatic interactions and SPIO nanoparticles modified with a potential targeting agent, lactose-glycine adduct (Lac-Gly), were subsequently immobilized on the surface of the PDDA-MWCNTs. A narrow magnetic hysteresis loop indicated that the product displayed superparamagnetism at room temperature which was further confirmed by ZFC (zero field cooling)/FC (field cooling) curves measured by SQUID. The multifunctional MWCNT-based magnetic nanocomposites showed low cytotoxicity in vitro to HEK293 and Huh7 cell lines. Enhanced T2 relaxivities were observed for the hybrid material (186 mM(-1) s(-1)) in comparison with the pure magnetic nanoparticles (92 mM(-1) s(-1)) due to the capacity of the MWCNTs to "carry" more nanoparticles as clusters. More importantly, after administration of the composite material to an in vivo liver cancer model in mice, a significant increase in tumor to liver contrast ratio (277%) was observed in T2 weighted magnetic resonance images. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  11. 3.0 T plaque imaging.

    PubMed

    Hinton-Yates, Denise P; Cury, Ricardo C; Wald, Lawrence L; Wiggins, Graham C; Keil, Boris; Seethmaraju, Ravi; Gangadharamurthy, Dakshinamurthy; Ogilvy, Christopher S; Dai, Guangping; Houser, Stuart L; Stone, James R; Furie, Karen L

    2007-10-01

    The aim of this article is to evaluate 3.0 T magnetic resonance imaging for characterization of vessel morphology and plaque composition. Emphasis is placed on early and moderate stages of carotid atherosclerosis, where increases in signal-to-noise (SNR) and contrast-to-noise (CNR) ratios compared with 1.5 T are sought. Comparison of in vivo 3.0 T imaging to histopathology is performed for validation. Parallel acceleration methods applied with an 8-channel carotid array are investigated as well as higher field ex vivo imaging to explore even further gains. The overall endeavor is to improve prospective assessment of atherosclerosis stage and stability for reduction of atherothrombotic event risk. A total of 10 male and female subjects ranging in age from 22 to 72 years (5 healthy and 5 with cardiovascular disease) participated. Custom-built array coils were used with endogenous and exogenous multicontrast bright and black-blood protocols for 3.0 T carotid imaging. Comparisons were performed to 1.5 T, and ex vivo plaque was stained with hematoxylin and eosin for histology. Imaging (9.4 T) was also performed on intact specimens. The factor of 2 gain in signal-to-noise SNR is realized compared with 1.5 T along with improved wall-lumen and plaque component CNR. Post-contrast black-blood imaging within 5-10 minutes of gadolinium injection is optimal for detection of the necrotic lipid component. In a preliminary 18-month follow-up study, this method provided measurement of a 50% reduction in lipid content with minimal change in plaque size in a subject receiving aggressive statin therapy. Parallel imaging applied with signal averaging further improves 3.0 T black-blood vessel wall imaging. The use of 3.0 T for carotid plaque imaging has demonstrated increases in SNR and CNR compared with 1.5 T. Quantitative prospective studies of moderate and early plaques are feasible at 3.0 T. Continued improvements in coil arrays, 3-dimensional pulse sequences, and the use of novel

  12. Gd-EOB-DTPA-enhanced T1ρ imaging vs diffusion metrics for assessment liver inflammation and early stage fibrosis of nonalcoholic steatohepatitis in rabbits.

    PubMed

    Xie, Yuanliang; Zhang, Hongfeng; Jin, Chaoling; Wang, Xiang; Wang, Xiaoqi; Chen, Jingting; Xu, Yikai

    2018-05-01

    To assess the value of T1ρ,T1ρ on hepatobiliary phase (HBP) and diffusion metrics in staging of Non-alcoholic fatty liver disease (NAFLD) activity scores, inflammation, fibrosis in NASH rabbits model. Non-alcoholic steatohepatitis (NASH) rabbits model was induced by feeding a varied duration of high-fat, high-cholesterol diet. T1ρ,T1ρ (HBP) 20min after administration of Gd-EOB-DTPA, and Intravoxel incoherent motion imaging (IVIM) diffusion-weighted imaging were performed on a 3.0T magnetic resonance (MR) imaging unit. The diagnostic value of each parameter for NAS, inflammation and fibrosis severity were determined. T1ρ (r=0.658) and T1ρ (HBP) (r=0.750) have strong association with NASH overall activity, T1ρ (HBP) is strongly relevant to inflammation stage (r=0.812). There was negative association between f and inflammation (r=-0.480), whilst no significant relation between other three parameters (apparent diffusion coefficient (ADC), pseudo-diffusion coefficient (D*) and true diffusion coefficient (D)) and inflammation or overall activity. The areas under the receiver operating characteristic curves (AUCs) of f, ADC, T1ρ and T1ρ-HBP were 0.871, 0.728, 0.849 and 0.949 for differentiating NASH; 0.731, 0.552, 0.925 and 0.922 for G2-3 inflammation; and 0.767, 0.625, 0.816, and 0.882 for S1-2 fibrosis. Comparison of ROC curve showed T1ρ (HBP) had an optimal diagnostic performance for NASH [T1ρ (HBP) vs ADC, AUC:0.949 vs 0.728, P=0.043], inflammation [T1ρ (HBP) vs ADC, AUC:0.922 vs 0.552, P=0.003], fibrosis [T1ρ (HBP) vs ADC, AUC:0.882 vs 0.625, P=0.046]. The combination of T1ρ (HBP)+perfusion fraction (f) showed highest diagnostic value for NASH (AUC:0.971), inflammation (AUC:0.935). Among T1ρ imaging and IVIM diffusion metrics, combination of T1rho (HBP)+f was found to be superior noninvasive imaging biomarker for NASH activity assessment. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Assessment of carotid stenosis using three-dimensional T2-weighted dark blood imaging: Initial experience.

    PubMed

    Mihai, Georgeta; Winner, Marshall W; Raman, Subha V; Rajagopalan, Sanjay; Simonetti, Orlando P; Chung, Yiu-Cho

    2012-02-01

    To evaluate the use of a T2-weighted SPACE sequence (T2w-SPACE) to assess carotid stenosis via several methods and compare its performance with contrast-enhanced magnetic resonance angiography (ceMRA). Fifteen patients with carotid atherosclerosis underwent dark blood (DB)-MRI using a 3D turbo spin echo with variable flip angles sequence (T2w-SPACE) and ceMRA. Images were coregistered and evaluated by two observers. Comparisons were made for luminal diameter, luminal area, degree of luminal stenosis (NASCET: North American Symptomatic Endarterectomy Trial; ECST: European Carotid Surgery Trial, and area stenosis), and vessel wall area. Degree of NASCET stenosis was clinically classified as mild (<50%), moderate (50%-69%), or severe (>69%). Excellent agreement was seen between ceMRA and T2w-SPACE and between observers for assessment of lumen diameter, lumen area, vessel wall area, and degree of NASCET stenosis (r > 0.80, P < 0.001). ECST stenosis was consistently higher than NASCET stenosis (48 ± 14% vs. 24 ± 22%, P < 0.001). Area stenosis (72 ± 2%) was significantly higher (P < 0.001) than both ESCT and NASCET stenosis. DB-MRI of carotid arteries using T2w-SPACE is clinically feasible. It provides accurate measurements of lumen size and degree of stenosis in comparison with ceMRA and offers a more reproducible measure of ECST stenosis than ceMRA. Copyright © 2011 Wiley Periodicals, Inc.

  14. Transcriptomic characterization of MRI contrast with focus on the T1-w/T2-w ratio in the cerebral cortex.

    PubMed

    Ritchie, Jacob; Pantazatos, Spiro P; French, Leon

    2018-07-01

    Magnetic resonance (MR) images of the brain are of immense clinical and research utility. At the atomic and subatomic levels, the sources of MR signals are well understood. However, we lack a comprehensive understanding of the macromolecular correlates of MR signal contrast. To address this gap, we used genome-wide measurements to correlate gene expression with MR signal intensity across the cerebral cortex in the Allen Human Brain Atlas (AHBA). We focused on the ratio of T1-weighted and T2-weighted intensities (T1-w/T2-w ratio image), which is considered to be a useful proxy for myelin content. As expected, we found enrichment of positive correlations between myelin-associated genes and the ratio image, supporting its use as a myelin marker. Genome-wide, there was an association with protein mass, with genes coding for heavier proteins expressed in regions with high T1-w/T2-w values. Oligodendrocyte gene markers were strongly correlated with the T1-w/T2-w ratio, but this was not driven by myelin-associated genes. Mitochondrial genes exhibit the strongest relationship, showing higher expression in regions with low T1-w/T2-w ratio. This may be due to the pH gradient in mitochondria as genes up-regulated by pH in the brain were also highly correlated with the ratio. While we corroborate associations with myelin and synaptic plasticity, differences in the T1-w/T2-w ratio across the cortex are more strongly linked to molecule size, oligodendrocyte markers, mitochondria, and pH. We evaluate correlations between AHBA transcriptomic measurements and a group averaged T1-w/T2-w ratio image, showing agreement with in-sample results. Expanding our analysis to the whole brain results in strong positive T1-w/T2-w correlations for immune system, inflammatory disease, and microglia marker genes. Genes with negative correlations were enriched for neuron markers and synaptic plasticity genes. Lastly, our findings are similar when performed on T1-w or inverted T2-w intensities alone

  15. Gadolinium embedded iron oxide nanoclusters as T1-T2 dual-modal MRI-visible vectors for safe and efficient siRNA delivery

    NASA Astrophysics Data System (ADS)

    Wang, Xiaoyong; Zhou, Zijian; Wang, Zhiyong; Xue, Yunxin; Zeng, Yun; Gao, Jinhao; Zhu, Lei; Zhang, Xianzhong; Liu, Gang; Chen, Xiaoyuan

    2013-08-01

    This report illustrates a new strategy of designing a T1-T2 dual-modal magnetic resonance imaging (MRI)-visible vector for siRNA delivery and MRI. Hydrophobic gadolinium embedded iron oxide (GdIO) nanocrystals are self-assembled into nanoclusters in the water phase with the help of stearic acid modified low molecular weight polyethylenimine (stPEI). The resulting water-dispersible GdIO-stPEI nanoclusters possess good stability, monodispersity with narrow size distribution and competitive T1-T2 dual-modal MR imaging properties. The nanocomposite system is capable of binding and delivering siRNA for knockdown of a gene of interest while maintaining its magnetic properties and biocompatibility. This new gadolinium embedded iron oxide nanocluster provides an important platform for safe and efficient gene delivery with non-invasive T1-T2 dual-modal MRI monitoring capability.This report illustrates a new strategy of designing a T1-T2 dual-modal magnetic resonance imaging (MRI)-visible vector for siRNA delivery and MRI. Hydrophobic gadolinium embedded iron oxide (GdIO) nanocrystals are self-assembled into nanoclusters in the water phase with the help of stearic acid modified low molecular weight polyethylenimine (stPEI). The resulting water-dispersible GdIO-stPEI nanoclusters possess good stability, monodispersity with narrow size distribution and competitive T1-T2 dual-modal MR imaging properties. The nanocomposite system is capable of binding and delivering siRNA for knockdown of a gene of interest while maintaining its magnetic properties and biocompatibility. This new gadolinium embedded iron oxide nanocluster provides an important platform for safe and efficient gene delivery with non-invasive T1-T2 dual-modal MRI monitoring capability. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr02797j

  16. Effects of different cooling treatments on water diffusion, microcirculation, and water content within exercised muscles: evaluation by magnetic resonance T2-weighted and diffusion-weighted imaging.

    PubMed

    Yanagisawa, Osamu; Takahashi, Hideyuki; Fukubayashi, Toru

    2010-09-01

    In this study, we determined the effects of different cooling treatments on exercised muscles. Seven adults underwent four post-exercise treatments (20-min ice-bag application, 60-min gel-pack application at 10 degrees C and 17 degrees C, and non-cooling treatment) with at least 1 week between treatments. Magnetic resonance diffusion- and T2-weighted images were obtained to calculate the apparent diffusion coefficients (apparent diffusion coefficient 1, which reflects intramuscular water diffusion and microcirculation, and apparent diffusion coefficient 2, which is approximately equal to the true diffusion coefficient that excludes as much of the effect of intramuscular microcirculation as possible) and the T2 values (intramuscular water content level) of the ankle dorsiflexors, respectively, before and after ankle dorsiflexion exercise and after post-exercise treatment. The T2 values increased significantly after exercise and returned to pre-exercise values after each treatment; no significant differences were observed among the four post-exercise treatments. Both apparent diffusion coefficients also increased significantly after exercise and decreased significantly after the three cooling treatments; no significant difference was detected among the three cooling treatments. Local cooling suppresses both water diffusion and microcirculation within exercised muscles. Moreover, although the treatment time was longer, adequate cooling effects could be achieved using the gel-pack applications at relatively mild cooling temperatures.

  17. Improved fat-suppression homogeneity with mDIXON turbo spin echo (TSE) in pediatric spine imaging at 3.0 T.

    PubMed

    Pokorney, Amber L; Chia, Jonathan M; Pfeifer, Cory M; Miller, Jeffrey H; Hu, Houchun H

    2017-11-01

    Background Robust fat suppression remains essential in clinical MRI to improve tissue signal contrast, minimize fat-related artifacts, and enhance image quality. Purpose To compare fat suppression between mDIXON turbo spin echo (TSE) and conventional frequency-selective and inversion-recovery methods in pediatric spine MRI. Material and Methods Images from T1-weighted (T1W) and T2-weighted (T2W) TSE sequences coupled with conventional methods and the mDIXON technique were compared in 36 patients (5.8 ± 5.4 years) at 3.0 T. Images from 42 pairs of T1W (n = 16) and T2W (n = 26) scans were acquired. Two radiologists reviewed the data and rated images using a three-point scale in two categories, including the uniformity of fat suppression and overall diagnostic image quality. The Wilcoxon rank-sum test was used to compare the scores. Results The Cohen's kappa coefficient for inter-rater agreement was 0.69 (95% confidence interval [CI], 0.56-0.83). Images from mDIXON TSE were considered superior in fat suppression ( P < 0.01) in 22 (rater 1) and 25 (rater 2) cases, respectively. In 13 (rater 1) and 11 (rater 2) cases, mDIXON TSE demonstrated improved diagnostic image quality ( P < 0.01). In three cases, fat suppression was superior using inversion-recovery and likewise in one case mDIXON had poorer image diagnostic quality. Lastly, mDIXON and conventional fat-suppression methods performed similarly in 17 (rater 1) and 14 (rater 2) cases, and yielded equal diagnostic image quality in 28 (rater 1) and 30 (rater 2) cases. Conclusion Robust fat suppression can be achieved with mDixon TSE pediatric spine imaging at 3.0 T and should be considered as a permanent replacement of traditional methods, in particular frequency-selective techniques.

  18. The preprocessed connectomes project repository of manually corrected skull-stripped T1-weighted anatomical MRI data.

    PubMed

    Puccio, Benjamin; Pooley, James P; Pellman, John S; Taverna, Elise C; Craddock, R Cameron

    2016-10-25

    Skull-stripping is the procedure of removing non-brain tissue from anatomical MRI data. This procedure can be useful for calculating brain volume and for improving the quality of other image processing steps. Developing new skull-stripping algorithms and evaluating their performance requires gold standard data from a variety of different scanners and acquisition methods. We complement existing repositories with manually corrected brain masks for 125 T1-weighted anatomical scans from the Nathan Kline Institute Enhanced Rockland Sample Neurofeedback Study. Skull-stripped images were obtained using a semi-automated procedure that involved skull-stripping the data using the brain extraction based on nonlocal segmentation technique (BEaST) software, and manually correcting the worst results. Corrected brain masks were added into the BEaST library and the procedure was repeated until acceptable brain masks were available for all images. In total, 85 of the skull-stripped images were hand-edited and 40 were deemed to not need editing. The results are brain masks for the 125 images along with a BEaST library for automatically skull-stripping other data. Skull-stripped anatomical images from the Neurofeedback sample are available for download from the Preprocessed Connectomes Project. The resulting brain masks can be used by researchers to improve preprocessing of the Neurofeedback data, as training and testing data for developing new skull-stripping algorithms, and for evaluating the impact on other aspects of MRI preprocessing. We have illustrated the utility of these data as a reference for comparing various automatic methods and evaluated the performance of the newly created library on independent data.

  19. Intensity ratio curve analysis of small renal masses on T2-weighted magnetic resonance imaging: Differentiation of fat-poor angiomyolipoma from renal cell carcinoma.

    PubMed

    Moriyama, Shingo; Yoshida, Soichiro; Tanaka, Hajime; Tanaka, Hiroshi; Yokoyama, Minato; Ishioka, Junichiro; Matsuoka, Yoh; Saito, Kazutaka; Kihara, Kazunori; Fujii, Yasuhisa

    2018-03-25

    To assess the diagnostic ability of a pixel intensity-based analysis in evaluating the magnetic resonance imaging characteristics of small renal masses, especially in differentiating fat-poor angiomyolipoma from renal cell carcinoma. T2-weighted images from 121 solid small renal masses (<4 cm) without visible fat (14 fat-poor angiomyolipomas, 92 clear cell renal cell carcinomas, six chromophobe renal cell carcinomas and nine papillary renal cell carcinomas) were retrospectively evaluated. An intensity ratio curve was plotted using intensity ratios, which were ratios of signal intensities of tumor pixels (each pixel along a linear region of interest drawn across the renal tumor on T2-weighted image) to the signal intensity of a normal renal cortex. The diagnostic ability of the intensity ratio curve analysis was evaluated. The tumors were classified into three types: intensity ratio fat-poor angiomyolipoma (n = 19) with no pseudocapsule, iso-low intensity and no heterogeneity; intensity ratio clear cell renal cell carcinoma (n = 76) with a pseudocapsule, iso-high intensity and heterogeneity; and other type of intensity ratio (n = 26), including tumors that did not fall into the above two categories. The sensitivity/specificity/accuracy of the intensity ratio curve analysis in diagnosing fat-poor angiomyolipoma was 93%/94%/94%, respectively. When the intensity ratio curve analysis was applied only to the tumor with undetermined radiological diagnosis, the sensitivity for diagnosing fat-poor angiomyolipoma compared with subjective reading alone significantly improved (93% vs 50%; P = 0.014). Our novel semiquantitative model for combined assessment of key features of fat-poor angiomyolipoma, including low intensity, homogeneity and absence of a pseudocapsule on T2-weighted image, might make diagnosis of fat-poor angiomyolipoma more accurate. © 2018 The Japanese Urological Association.

  20. Pediatric Patients Demonstrate Progressive T1-Weighted Hyperintensity in the Dentate Nucleus following Multiple Doses of Gadolinium-Based Contrast Agent.

    PubMed

    Roberts, D R; Chatterjee, A R; Yazdani, M; Marebwa, B; Brown, T; Collins, H; Bolles, G; Jenrette, J M; Nietert, P J; Zhu, X

    2016-12-01

    While there have been recent reports of brain retention of gadolinium following gadolinium-based contrast agent administration in adults, a retrospective series of pediatric patients has not previously been reported, to our knowledge. We investigated the relationship between the number of prior gadolinium-based contrast agent doses and increasing T1 signal in the dentate nucleus on unenhanced T1-weighted MR imaging. We hypothesized that despite differences in pediatric physiology and the smaller gadolinium-based contrast agent doses that pediatric patients are typically administered based on weighted-adjusted dosing, the pediatric brain would also demonstrate dose-dependent increasing T1 signal in the dentate nucleus. We included children with multiple gadolinium-based contrast agent administrations at our institution. A blinded reader placed ROIs within the dentate nucleus and adjacent cerebellar white matter. To eliminate reader bias, we also performed automated ROI delineation of the dentate nucleus, cerebellar white matter, and pons. Dentate-to-cerebellar white matter and dentate-to pons ratios were compared with the number of gadolinium-based contrast agent administrations. During 20 years at our institution, 280 patients received at least 5 gadolinium-based contrast agent doses, with 1 patient receiving 38 doses. Sixteen patients met the inclusion/exclusion criteria for ROI analysis. Blinded reader dentate-to-cerebellar white matter ratios were significantly associated with gadolinium-based contrast agent doses (r s = 0.77, P = .001). The dentate-to-pons ratio and dentate-to-cerebellar white matter ratios based on automated ROI placement were also significantly correlated with gadolinium-based contrast agent doses (t = 4.98, P < .0001 and t = 2.73, P < .02, respectively). In pediatric patients, the number of prior gadolinium-based contrast agent doses is significantly correlated with progressive T1-weighted dentate hyperintensity. Definitive confirmation of

  1. Added value of high-b-value (b = 3000 s/mm2) diffusion-weighted imaging at 3 T in relation to fluid-attenuated inversion recovery images for the evaluation of cortical lesions in inflammatory brain diseases.

    PubMed

    Iwashita, Koya; Hirai, Toshinori; Kitajima, Mika; Shigematsu, Yoshinori; Uetani, Hiroyuki; Iryo, Yasuhiko; Azuma, Minako; Hayashida, Eri; Ando, Yukio; Murakami, Ryuji; Yamashita, Yasuyuki

    2013-01-01

    The purpose of this study was to determine how the gray-to-white matter contrast in healthy subjects changes on high-b-value diffusion-weighted imaging (DWI) acquired at 3 T and evaluate whether high-b-value DWI at 3 T is useful for the detection of cortical lesions in inflammatory brain diseases. Ten healthy volunteers underwent DWI at b = 1000, 2000, 3000, 4000, and 5000 s/mm(2) on a 3-T MRI unit. On DW images, 1 radiologist performed region-of-interest measurements of the signal intensity of 8 gray matter structures. The gray-to-white matter contrast ratio (GWCR) was calculated. Ten patients with inflammatory cortical lesions were also included. All patients underwent conventional MRI and DWI at b = 1000 and 3000 s/mm(2). Using a 4-point grading system, 2 radiologists independently assessed the presence of additional information on DW images compared with fluid-attenuated inversion recovery images. Interobserver agreement was assessed by κ statistics. In the healthy subjects, the b value increased as the GWCR decreased in all evaluated gray matter structures. On DW images acquired at b = 3000 s/mm(2), mean GWCR was less than 1.0 in 7 of 8 structures. For both reviewers, DWI at b = 3000 s/mm(2) yielded significantly more additional information than did DWI at b = 1000 s/mm(2) (P < 0.05). Interobserver agreement for DWI at b = 1000 s/mm(2) and b = 3000 s/mm(2) was fair (κ = 0.35) and excellent (κ = 1.0), respectively. At 3-T DWI, the gray-to-white matter contrast in most gray matter structures reverses at b = 3000 s/mm. In the evaluation of cortical lesions in patients with inflammatory brain diseases, 3-T DWI at b = 3000 s/mm was more useful than b = 1000 s/mm(2).

  2. Feasibility of imaging superficial palmar arch using micro-ultrasound, 7T and 3T magnetic resonance imaging.

    PubMed

    Pruzan, Alison N; Kaufman, Audrey E; Calcagno, Claudia; Zhou, Yu; Fayad, Zahi A; Mani, Venkatesh

    2017-02-28

    To demonstrate feasibility of vessel wall imaging of the superficial palmar arch using high frequency micro-ultrasound, 7T and 3T magnetic resonance imaging (MRI). Four subjects (ages 22-50 years) were scanned on a micro-ultrasound system with a 45-MHz transducer (Vevo 2100, VisualSonics). Subjects' hands were then imaged on a 3T clinical MR scanner (Siemens Biograph MMR) using an 8-channel special purpose phased array carotid coil. Lastly, subjects' hands were imaged on a 7T clinical MR scanner (Siemens Magnetom 7T Whole Body Scanner) using a custom built 8-channel transmit receive carotid coil. All three imaging modalities were subjectively analyzed for image quality and visualization of the vessel wall. Results of this very preliminary study indicated that vessel wall imaging of the superficial palmar arch was feasible with a whole body 7T and 3T MRI in comparison with micro-ultrasound. Subjective analysis of image quality (1-5 scale, 1: poorest, 5: best) from B mode, ultrasound, 3T SPACE MRI and 7T SPACE MRI indicated that the image quality obtained at 7T was superior to both 3T MRI and micro-ultrasound. The 3D SPACE sequence at both 7T and 3T MRI with isotropic voxels allowed for multi-planar reformatting of images and allowed for less operator dependent results as compared to high frequency micro-ultrasound imaging. Although quantitative analysis revealed that there was no significant difference between the three methods, the 7T Tesla trended to have better visibility of the vessel and its wall. Imaging of smaller arteries at the 7T is feasible for evaluating atherosclerosis burden and may be of clinical relevance in multiple diseases.

  3. Is There an Additional Value of {sup 11}C-Choline PET-CT to T2-weighted MRI Images in the Localization of Intraprostatic Tumor Nodules?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van den Bergh, Laura, E-mail: laura.vandenbergh@uzleuven.be; Koole, Michel; Isebaert, Sofie

    2012-08-01

    Purpose: To investigate the additional value of {sup 11}C-choline positron emission tomography (PET)-computed tomography (CT) to T2-weighted (T2w) magnetic resonance imaging (MRI) for localization of intraprostatic tumor nodules. Methods and Materials: Forty-nine prostate cancer patients underwent T2w MRI and {sup 11}C-choline PET-CT before radical prostatectomy and extended lymphadenectomy. Tumor regions were outlined on the whole-mount histopathology sections and on the T2w MR images. Tumor localization was recorded in the basal, middle, and apical part of the prostate by means of an octant grid. To analyze {sup 11}C-choline PET-CT images, the same grid was used to calculate the standardized uptake valuesmore » (SUV) per octant, after rigid registration with the T2w MR images for anatomic reference. Results: In total, 1,176 octants were analyzed. Sensitivity, specificity, and accuracy of T2w MRI were 33.5%, 94.6%, and 70.2%, respectively. For {sup 11}C-choline PET-CT, the mean SUV{sub max} of malignant octants was significantly higher than the mean SUV{sub max} of benign octants (3.69 {+-} 1.29 vs. 3.06 {+-} 0.97, p < 0.0001) which was also true for mean SUV{sub mean} values (2.39 {+-} 0.77 vs. 1.94 {+-} 0.61, p < 0.0001). A positive correlation was observed between SUV{sub mean} and absolute tumor volume (Spearman r = 0.3003, p = 0.0362). No correlation was found between SUVs and prostate-specific antigen, T-stage or Gleason score. The highest accuracy (61.1%) was obtained with a SUV{sub max} cutoff of 2.70, resulting in a sensitivity of 77.4% and a specificity of 44.9%. When both modalities were combined (PET-CT or MRI positive), sensitivity levels increased as a function of SUV{sub max} but at the cost of specificity. When only considering suspect octants on {sup 11}C-choline PET-CT (SUV{sub max} {>=} 2.70) and T2w MRI, 84.7% of these segments were in agreement with the gold standard, compared with 80.5% for T2w MRI alone. Conclusions: The additional value

  4. Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist.

    PubMed

    Park, Hee Jin; Lee, So Yeon; Kang, Kyung A; Kim, Eun Young; Shin, Hun Kyu; Park, Se Jin; Park, Jai Hyung; Kim, Eugene

    2018-04-01

    To compare image quality of three-dimensional volume isotropic T 2 weighted fast spin echo (3D VISTA) and two-dimensional (2D) T 2 weighted images (T2WI) for evaluation of triangular fibrocartilage (TFC) and to investigate whether 3D VISTA can replace 2D T 2 WI in evaluating TFC injury. This retrospective study included 69 patients who received wrist MRIs using both 2D T 2 WI and 3D VISTA techniques for assessment of wrist pathology, including TFC injury. Two radiologists measured the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) of the two sequences. The anatomical identification score and diagnostic performance were independently assessed by two interpreters. The diagnostic abilities of 3D VISTA and 2D T 2 WI were analysed by sensitivity, specificity and accuracy for diagnosing TFC injury using surgically or clinically confirmed diagnostic reference standards. 17 cases (25%) were classified as having TFC injury. 2 cases (12%) were diagnosed surgically, and 15 cases (88%) were diagnosed by physical examination. 52 cases (75%) were diagnosed as having intact TFC. 8 of these cases (15%) were surgically confirmed, while the others were diagnosed by physical examination and clinical findings. The 3D VISTA images had significantly higher SNR and CNR values for the TFC than 2D T 2 WI images. The scores of 3D VISTA's total length, full width and sharpness were similar to those of 2D T 2 WI. We were unable to find a significant difference between 3D VISTA and 2D T 2 WI in the ability to diagnose TFC injury. 3D VISTA image quality is similar to that of 2D T 2 WI for TFC evaluation and is also excellent for tissue contrast. 3D VISTA can replace 2D images in TFC injury assessment. Advances in knowledge: 3D VISTA image quality is similar to that of 2D T 2 WI for TFC evaluation and is also excellent for tissue contrast. 3D VISTA can replace 2D images in TFC injury assessment.

  5. Primary Uterine Peripheral T-cell Lymphoma

    PubMed Central

    Gong, Jing; Dong, Aisheng; Wang, Yang; Zhang, Xuefeng; Yang, Panpan; Wang, Li; Jing, Wei

    2016-01-01

    Abstract Primary uterine non-Hodgkin's lymphoma is extremely rare accounting for <1% of all extranodal non-Hodgkin's lymphomas. Imaging findings of primary uterine lymphoma have rarely been reported before. We present magnetic resonance imaging (MRI) and fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT findings in a patient with primary uterine peripheral T-cell lymphoma. A 27-year-old female presented with intermittent fever with neutropenia for 7 months. MRI showed an ill-defined mass involved both the uterine corpus and cervix, resulting in diffuse enlargement of the uterus. This mass showed inhomogeneous hypointensity on unenhanced T1-weighted images, hyperintensity on diffusion-weighted imaging, relative hypointensity compared to the surrounding myometrium on T2-weighted images and lower enhancement than the surrounding myometrium on enhanced T1-weighted images. FDG PET/CT showed intense FDG uptake in the thickened wall of the uterine corpus and cervix with SUVmax of 26.9. There were multiple hypermetabolic lymph nodes in the pelvis and retroperitoneum. Uterine curettage and CT-guided biopsy of the uterine mass revealed peripheral T-cell lymphoma. Bone marrow biopsy revealed no evidence of lymphomatous involvement. The imaging and pathologic findings were consistent with primary uterine lymphoma. After 3 circles of chemotherapy, follow-up enhanced MRI showed decreased thickness of the uterine wall. Despite its rarity, primary uterine non-Hodgkin's lymphoma should be taken into consideration when a uterine tumor shows large size, relative hypointesity on both T2-weighted images and enhanced T1-weighted images compared to the surrounding myometrium, and intense FDG uptake on PET/CT. MRI may be helpful for describing the relationship between the tumor and adjacent structures. FDG PET/CT may be useful for tumor detection and staging. PMID:27124063

  6. Evaluation of MRI sequences for quantitative T1 brain mapping

    NASA Astrophysics Data System (ADS)

    Tsialios, P.; Thrippleton, M.; Glatz, A.; Pernet, C.

    2017-11-01

    T1 mapping constitutes a quantitative MRI technique finding significant application in brain imaging. It allows evaluation of contrast uptake, blood perfusion, volume, providing a more specific biomarker of disease progression compared to conventional T1-weighted images. While there are many techniques for T1-mapping there is a wide range of reported T1-values in tissues, raising the issue of protocols reproducibility and standardization. The gold standard for obtaining T1-maps is based on acquiring IR-SE sequence. Widely used alternative sequences are IR-SE-EPI, VFA (DESPOT), DESPOT-HIFI and MP2RAGE that speed up scanning and fitting procedures. A custom MRI phantom was used to assess the reproducibility and accuracy of the different methods. All scans were performed using a 3T Siemens Prisma scanner. The acquired data processed using two different codes. The main difference was observed for VFA (DESPOT) which grossly overestimated T1 relaxation time by 214 ms [126 270] compared to the IR-SE sequence. MP2RAGE and DESPOT-HIFI sequences gave slightly shorter time than IR-SE (~20 to 30ms) and can be considered as alternative and time-efficient methods for acquiring accurate T1 maps of the human brain, while IR-SE-EPI gave identical result, at a cost of a lower image quality.

  7. Low signal intensity in motor cortex on susceptibility-weighted MR imaging is correlated with clinical signs of amyotrophic lateral sclerosis: a pilot study.

    PubMed

    Endo, Hironobu; Sekiguchi, Kenji; Shimada, Hitoshi; Ueda, Takehiro; Kowa, Hisatomo; Kanda, Fumio; Toda, Tatsushi

    2018-03-01

    There is no reliable objective indicator for upper motor neuron dysfunction in amyotrophic lateral sclerosis (ALS). To determine the clinical significance and potential utility of magnetic resonance (MR) signals, we investigated the relationship between clinical symptoms and susceptibility changes in the motor cortex measured using susceptibility-weighted MR imaging taken by readily available 3-T MRI in clinical practice. Twenty-four ALS patients and 14 control subjects underwent 3-T MR T1-weighted imaging and susceptibility-weighted MR imaging with the principles of echo-shifting with a train of observations (PRESTO) sequence. We analysed relationships between relative susceptibility changes in the motor cortex assessed using voxel-based analysis (VBA) and clinical scores, including upper motor neuron score, ALS functional rating scale revised score, and Medical Research Council sum score on physical examination. Patients with ALS exhibited significantly lower signal intensity in the precentral gyrus on susceptibility-weighted MR imaging compared with controls. Clinical scores were significantly correlated with susceptibility changes. Importantly, the extent of the susceptibility changes in the bilateral precentral gyri was significantly correlated with upper motor neuron scores. The results of our pilot study using VBA indicated that low signal intensity in motor cortex on susceptibility-weighted MR imaging may correspond to clinical symptoms, particularly upper motor neuron dysfunction. Susceptibility-weighted MR imaging may be a useful diagnostic tool as an objective indicator of upper motor neuron dysfunction.

  8. The correlation between biological activity and diffusion-weighted MR imaging and ADC value in cases with prostate cancer.

    PubMed

    Sokmen, Bedriye Koyuncu; Sokmen, Dogukan; Ucar, Nese; Ozkurt, Huseyin; Simsek, Abdulmuttalip

    2017-12-31

    Firstly, we aimed to investigate the correlation among dynamic contrasted magnetic resonance (MR) images, diffusion-weighted MR images, and apparent diffusion coefficent (ADC) values in patients with prostate cancer. Secondly, we aimed to investigate the roles of these variables on clinical risk classification and the biological behavior of the prostate cancer. A total of sixty with prostatic adenocarcinoma patients diagnosed between January 2011 and May 2013 were retrospectively included in the study. Risk classification of patients were evaluated as low-risk (Group 1) (n = 20) (Stage T1c-T2a, PSA < 10 ng/ml, Gleason Score < 7), moderate-risk (Group 2) (n = 18) (Stage T1b-T2c, PSA = 10-20 ng/ml, Gleason Score = 7) and high-risk (Group 3) (n = 22) (Stage > T3a, PSA > 20 ng/ml, Gleason Score > 7). Diffusion-weighted MR images, dynamic contrasted MR images, and ADC values of the prostates were correlated. ADC values of the cases in Group 3 were lower than those of the other groups (p < 0.001). ADC values of the areas without malignancy did not differ significantly between groups (p > 0.05). Biological activity of the tumor tissue was determined by GS, while a negative correlation was observed between GSs and ADC values of the patients, (p < 0.001). In tumors with higher Gleason scores, lower ADC values were obtained. These measured values can play a role in the noninvasive determination of the cellularity of the tumoral mass.

  9. Hyperecho PROPELLER-MRI: Application to rapid high-resolution motion-insensitive T2 -weighted black-blood imaging of the carotid arterial vessel wall and plaque.

    PubMed

    Yoneyama, Masami; Nakamura, Masanobu; Obara, Makoto; Okuaki, Tomoyuki; Sashi, Ryuji; Sawano, Seishi; Tatsuno, Satoshi; Van Cauteren, Marc

    2017-02-01

    To demonstrate the usefulness of hyperecho and PROPELLER (HEP) for carotid arterial vessel wall imaging by using a quantitative comparison with conventional methods. PROPELLER is a motion-insensitive turbo spin-echo (TSE) sequence and has recently been utilized in magnetic resonance (MR) plaque imaging instead of double inversion recovery TSE (DIR-TSE). Wider blade-width, higher k-space density, and an improved blood suppression effect result in better image quality. In this study we introduce a new combination of HEP. A total of 17 subjects were examined on a 3.0T system. We conducted quantitative comparisons for signal-to-noise ratio (SNR), contrast-to-noise-ratio, and image sharpness among HEP, DIR-TSE, and conventional PROPELLER (c-PROPELLER). Subsequently, images obtained with DIR-TSE, c-PROPELLER, and HEP were visually evaluated using a three-point scale by two board-certified radiologists. HEP showed high SNR similar to c-PROPELLER, good T 2 contrast approximating DIR-TSE, and better blood suppression compared with the other two methods (P < 0.05). The image sharpness of HEP (2.55 ± 0.53) was higher than that of DIR-TSE (1.89 ± 0.33) and the absence of ghost or streak artifacts in HEP (2.89 ± 0.33) was better than that in both other methods (2.22 ± 0.83 for DIR-TSE and 2.00 ± 0.50 for c-PROPELLER) (P < 0.05). Furthermore, the degree of blood suppression, particularly in cases of slow or turbulent flow close to the atherosclerotic plaque, was identical for HEP (2.80 ± 0.45) and DIR-TSE (2.80 ± 0.45) but was significantly better than for c-PROPELLER (1.60 ± 0.55) (P < 0.05). This study demonstrates the usefulness of HEP in the carotid arteries. HEP can provide higher-resolution T 2 -weighted black-blood imaging without flow- and/or motion-related artifacts, compared to conventional techniques. 3 J. Magn. Reson. Imaging 2017;45:515-524. © 2016 International Society for Magnetic Resonance in Medicine.

  10. Optic radiations are thinner and show signs of iron deposition in patients with long-standing remitting-relapsing multiple sclerosis: an enhanced T2*-weighted angiography imaging study.

    PubMed

    Zeng, Chun; Du, Silin; Han, Yongliang; Fu, Jialiang; Luo, Qi; Xiang, Yayun; Chen, Xiaoya; Luo, Tianyou; Li, Yongmei; Zheng, Yineng

    2018-04-30

    This study aimed to investigate iron deposition and thickness and signal changes in optic radiation (OR) by enhanced T 2 * -weighted angiography imaging (ESWAN) in patients with relapsing-remitting multiple sclerosis (RRMS) with unilateral and bilateral lesions or no lesions. Fifty-one RRMS patients (42 patients with a disease duration [DD] ≥ 2 years [group Mor], nine patients with a DD < 2 years [group Les]) and 51 healthy controls (group Con) underwent conventional magnetic resonance imaging (MRI) and ESWAN at 3.0 T. The mean phase value (MPV) of the OR was measured on the phase image, and thickness and signal changes of the OR were observed on the magnitude image. The average MPVs for the OR were 1,981.55 ± 7.75 in group Mor, 1,998.45 ± 2.01 in group Les, and 2,000.48 ± 5.53 in group Con. In group Mor, 28 patients with bilateral OR lesions showed bilateral OR thinning with a heterogeneous signal, and 14 patients with unilateral OR lesions showed ipsilateral OR thinning with a heterogeneous signal. In the remaining nine patients without OR lesions and in group Con, the bilateral OR had a normal appearance. In the patients, a negative correlation was found between DD and OR thickness and a positive correlation was found between MPV and OR thickness. We confirmed iron deposition in the OR in the RRMS patients, and the OR thickness was lower in the patients than in the controls. • Enhanced T 2 * -weighted magnetic resonance angiography (ESWAN) provides new insights into multiple sclerosis (MS). • Focal destruction of the optic radiation (OR) is detectable by ESWAN. • Iron deposition in OR can be measured on ESWAN phase image in MS patients. • OR thickness was lower in the patients than in the controls. • Iron deposition and thickness changes of the OR are associated with disease duration.

  11. T1 and susceptibility contrast at high fields

    NASA Astrophysics Data System (ADS)

    Neelavalli, Jaladhar

    partly because of the invariance of most tissue susceptibilities with field strength. This essentially ensures a constant available phase contrast between tissues across field strengths. In fact, with the increased SNR at high fields, the phase CNR actually increases with field strength which is even better. Susceptibility weighted imaging, which uniquely combines this phase and magnitude information to generate enhanced susceptibility contrast magnitude images, has proven to be an important tool in the study of various neurological conditions like, Alzheimer's, Parkinson's, Huntington's disease and multiple sclerosis even at conventional field strength of 1.5T and should have more applicability at high fields. A major issue in using phase images for susceptibility contrast, directly or as processed SWI magnitude images, is the large scale background phase variations that obscure the local susceptibility based contrast. A novel method is proposed for removing such geometrically induced large scale phase variations using a Fourier Transform based field calculation method. It is shown that the new method is capable of successfully removing the background field effects. It is shown that the new method is not only capable of successfully removing the background field effects but also helps in preserving more local phase information.

  12. Cardiac Magnetic Resonance Imaging Using an Open 1.0T MR Platform: A Comparative Study with a 1.5T Tunnel System.

    PubMed

    Fischbach, Katharina; Kosiek, Otrud; Friebe, Björn; Wybranski, Christian; Schnackenburg, Bernhard; Schmeisser, Alexander; Smid, Jan; Ricke, Jens; Pech, Maciej

    2017-01-01

    Cardiac magnetic resonance imaging (cMRI) has become the non-invasive reference standard for the evaluation of cardiac function and viability. The introduction of open, high-field, 1.0T (HFO) MR scanners offers advantages for examinations of obese, claustrophobic and paediatric patients.The aim of our study was to compare standard cMRI sequences from an HFO scanner and those from a cylindrical, 1.5T MR system. Fifteen volunteers underwent cMRI both in an open HFO and in a cylindrical MR system. The protocol consisted of cine and unenhanced tissue sequences. The signal-to-noise ratio (SNR) for each sequence and blood-myocardium contrast for the cine sequences were assessed. Image quality and artefacts were rated. The location and number of non-diagnostic segments was determined. Volunteers' tolerance to examinations in both scanners was investigated. SNR was significantly lower in the HFO scanner (all p<0.001). However, the contrast of the cine sequence was significantly higher in the HFO platform compared to the 1.5T MR scanner (0.685±0.41 vs. 0.611±0.54; p<0.001). Image quality was comparable for all sequences (all p>0.05). Overall, only few non-diagnostic myocardial segments were recorded: 6/960 (0.6%) by the HFO and 17/960 (1.8%) segments by the cylindrical system. The volunteers expressed a preference for the open MR system (p<0.01). Standard cardiac MRI sequences in an HFO platform offer a high image quality that is comparable to the quality of images acquired in a cylindrical 1.5T MR scanner. An open scanner design may potentially improve tolerance of cardiac MRI and therefore allow to examine an even broader patient spectrum.

  13. Abdominopelvic 1.5-T and 3.0-T MR Imaging in Healthy Volunteers: Relationship to Formation of DNA Double-Strand Breaks.

    PubMed

    Suntharalingam, Saravanabavaan; Mladenov, Emil; Sarabhai, Theresia; Wetter, Axel; Kraff, Oliver; Quick, Harald H; Forsting, Michael; Iliakis, Georg; Nassenstein, Kai

    2018-05-01

    Purpose To investigate the relationship between abdominopelvic magnetic resonance (MR) imaging and formation of DNA double-strand breaks (DSBs) in peripheral blood lymphocytes among a cohort of healthy volunteers. Materials and Methods Blood samples were obtained from 40 healthy volunteers (23 women and 17 men; mean age, 27.2 years [range, 21-37 years]) directly before and 5 and 30 minutes after abdominopelvic MR imaging performed at 1.5 T (n = 20) or 3.0 T (n = 20). The number of DNA DSBs in isolated blood lymphocytes was quantified after indirect immunofluorescent staining of a generally accepted DSB marker, γ-H2AX, by means of high-throughput automated microscopy. As a positive control of DSB induction, blood lymphocytes from six volunteers were irradiated in vitro with x-rays at a dose of 1 Gy (70-90 keV). Statistical analysis was performed by using a Friedman test. Results No significant alteration in the frequency of DNA DSB induction was observed after MR imaging (before imaging: 0.22 foci per cell, interquartile range [IQR] = 0.54 foci per cell; 5 minutes after MR imaging: 0.08 foci per cell, IQR = 0.39 foci per cell; 30 minutes after MR imaging: 0.09 foci per cell, IQR = 0.63 foci per cell; P = .057). In vitro radiation of lymphocytes with 1 Gy led to a significant increase in DSBs (0.22 vs 3.43 foci per cell; P = .0312). The frequency of DSBs did not differ between imaging at 1.5 T and at 3.0 T (5 minutes after MR imaging: 0.23 vs 0.06 foci per cell, respectively [P = .57]; 30 minutes after MR imaging: 0.12 vs 0.08 foci per cell [P = .76]). Conclusion Abdominopelvic MR imaging performed at 1.5 T or 3.0 T does not affect the formation of DNA DSBs in peripheral blood lymphocytes. © RSNA, 2018.

  14. Evaluation of dual-source parallel RF excitation for diffusion-weighted whole-body MR imaging with background body signal suppression at 3.0 T.

    PubMed

    Mürtz, Petra; Kaschner, Marius; Träber, Frank; Kukuk, Guido M; Büdenbender, Sarah M; Skowasch, Dirk; Gieseke, Jürgen; Schild, Hans H; Willinek, Winfried A

    2012-11-01

    To evaluate the use of dual-source parallel RF excitation (TX) for diffusion-weighted whole-body MRI with background body signal suppression (DWIBS) at 3.0 T. Forty consecutive patients were examined on a clinical 3.0-T MRI system using a diffusion-weighted (DW) spin-echo echo-planar imaging sequence with a combination of short TI inversion recovery and slice-selective gradient reversal fat suppression. DWIBS of the neck (n=5), thorax (n=8), abdomen (n=6) and pelvis (n=21) was performed both with TX (2:56 min) and with standard single-source RF excitation (4:37 min). The quality of DW images and reconstructed inverted maximum intensity projections was visually judged by two readers (blinded to acquisition technique). Signal homogeneity and fat suppression were scored as "improved", "equal", "worse" or "ambiguous". Moreover, the apparent diffusion coefficient (ADC) values were measured in muscles, urinary bladder, lymph nodes and lesions. By the use of TX, signal homogeneity was "improved" in 25/40 and "equal" in 15/40 cases. Fat suppression was "improved" in 17/40 and "equal" in 23/40 cases. These improvements were statistically significant (p<0.001, Wilcoxon signed-rank test). In five patients, fluid-related dielectric shading was present, which improved remarkably. The ADC values did not significantly differ for the two RF excitation methods (p=0.630 over all data, pairwise Student's t-test). Dual-source parallel RF excitation improved image quality of DWIBS at 3.0 T with respect to signal homogeneity and fat suppression, reduced scan time by approximately one-third, and did not influence the measured ADC values. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  15. Differentiation of malignant from benign soft tissue tumours: use of additive qualitative and quantitative diffusion-weighted MR imaging to standard MR imaging at 3.0 T.

    PubMed

    Lee, So-Yeon; Jee, Won-Hee; Jung, Joon-Yong; Park, Michael Y; Kim, Sun-Ki; Jung, Chan-Kwon; Chung, Yang-Guk

    2016-03-01

    To determine the added value of diffusion-weighted imaging (DWI) to standard magnetic resonance imaging (MRI) to differentiate malignant from benign soft tissue tumours at 3.0 T. 3.0 T MR images including DWI in 63 patients who underwent surgery for soft tissue tumours were retrospectively analyzed. Two readers independently interpreted MRI for the presence of malignancy in two steps: standard MRI alone, standard MRI and DWI with qualitative and quantitative analysis combined. There were 34 malignant and 29 non-malignant soft tissue tumours. In qualitative analysis, hyperintensity relative to skeletal muscle was more frequent in malignant than benign tumours on DWI (P=0.003). In quantitative analysis, ADCs of malignant tumours were significantly lower than those of non-malignant tumours (P≤0.002): 759±385 vs. 1188±423 μm(2)/sec minimum ADC value, 941±440 vs. 1310±440 μm(2)/sec average ADC value. The mean sensitivity, specificity and accuracy of both readers were 96%, 72%, and 85% on standard MRI alone and 97%, 90%, and 94% on standard MRI with DWI. The addition of DWI to standard MRI improves the diagnostic accuracy for differentiation of malignant from benign soft tissue tumours at 3.0 T. DWI has added value for differentiating malignant from benign soft tissue tumours. Addition of DWI to standard MRI at 3.0 T improves the diagnostic accuracy. Measurements of both ADC min within solid portion and ADC av are helpful.

  16. Sodium and T1ρ MRI for molecular and diagnostic imaging of articular cartilage†

    PubMed Central

    Borthakur, Arijitt; Mellon, Eric; Niyogi, Sampreet; Witschey, Walter; Kneeland, J. Bruce; Reddy, Ravinder

    2010-01-01

    In this article, both sodium magnetic resonance (MR) and T1ρ relaxation mapping aimed at measuring molecular changes in cartilage for the diagnostic imaging of osteoarthritis are reviewed. First, an introduction to structure of cartilage, its degeneration in osteoarthritis (OA) and an outline of diagnostic imaging methods in quantifying molecular changes and early diagnostic aspects of cartilage degeneration are described. The sodium MRI section begins with a brief overview of the theory of sodium NMR of biological tissues and is followed by a section on multiple quantum filters that can be used to quantify both bi-exponential relaxation and residual quadrupolar interaction. Specifically, (i) the rationale behind the use of sodium MRI in quantifying proteoglycan (PG) changes, (ii) validation studies using biochemical assays, (iii) studies on human OA specimens, (iv) results on animal models and (v) clinical imaging protocols are reviewed. Results demonstrating the feasibility of quantifying PG in OA patients and comparison with that in healthy subjects are also presented. The section concludes with the discussion of advantages and potential issues with sodium MRI and the impact of new technological advancements (e.g. ultra-high field scanners and parallel imaging methods). In the theory section on T1ρ, a brief description of (i) principles of measuring T1ρ relaxation, (ii) pulse sequences for computing T1ρ relaxation maps, (iii) issues regarding radio frequency power deposition, (iv) mechanisms that contribute to T1ρ in biological tissues and (v) effects of exchange and dipolar interaction on T1ρ dispersion are discussed. Correlation of T1ρ relaxation rate with macromolecular content and biomechanical properties in cartilage specimens subjected to trypsin and cytokine-induced glycosaminoglycan depletion and validation against biochemical assay and histopathology are presented. Experimental T1ρ data from osteoarthritic specimens, animal models, healthy human

  17. Sodium and T1rho MRI for molecular and diagnostic imaging of articular cartilage.

    PubMed

    Borthakur, Arijitt; Mellon, Eric; Niyogi, Sampreet; Witschey, Walter; Kneeland, J Bruce; Reddy, Ravinder

    2006-11-01

    In this article, both sodium magnetic resonance (MR) and T1rho relaxation mapping aimed at measuring molecular changes in cartilage for the diagnostic imaging of osteoarthritis are reviewed. First, an introduction to structure of cartilage, its degeneration in osteoarthritis (OA) and an outline of diagnostic imaging methods in quantifying molecular changes and early diagnostic aspects of cartilage degeneration are described. The sodium MRI section begins with a brief overview of the theory of sodium NMR of biological tissues and is followed by a section on multiple quantum filters that can be used to quantify both bi-exponential relaxation and residual quadrupolar interaction. Specifically, (i) the rationale behind the use of sodium MRI in quantifying proteoglycan (PG) changes, (ii) validation studies using biochemical assays, (iii) studies on human OA specimens, (iv) results on animal models and (v) clinical imaging protocols are reviewed. Results demonstrating the feasibility of quantifying PG in OA patients and comparison with that in healthy subjects are also presented. The section concludes with the discussion of advantages and potential issues with sodium MRI and the impact of new technological advancements (e.g. ultra-high field scanners and parallel imaging methods). In the theory section on T1rho, a brief description of (i) principles of measuring T1rho relaxation, (ii) pulse sequences for computing T1rho relaxation maps, (iii) issues regarding radio frequency power deposition, (iv) mechanisms that contribute to T1rho in biological tissues and (v) effects of exchange and dipolar interaction on T1rho dispersion are discussed. Correlation of T1rho relaxation rate with macromolecular content and biomechanical properties in cartilage specimens subjected to trypsin and cytokine-induced glycosaminoglycan depletion and validation against biochemical assay and histopathology are presented. Experimental T1rho data from osteoarthritic specimens, animal models

  18. Correlation of the near-infrared spectroscopy signals with signal intensity in T(2)-weighted magnetic resonance imaging of the human masseter muscle.

    PubMed

    Kuboki, T; Suzuki, K; Maekawa, K; Inoue-Minakuchi, M; Acero, C O; Yanagi, Y; Wakasa, T; Kishi, K; Yatani, H; Clark, G T

    2001-08-01

    The purpose of this study was to compare and contrast blood volume changes transcutaneously measured using near-infrared (NIR) spectroscopy against water signal intensity changes taken from a transverse T(2)-weighted MR image of the masseter muscle in healthy human subjects before, during and after contraction. Eight healthy non-smoking males with no history of chronic muscle pain or vascular headaches participated (mean age: 23.9+/-0.6 years). The MRI data were gathered using a turbo spin echo sequence (TR: 2300 ms; TE: 90 ms; FOV: 188x300 mm; scanning time: 30 s; slice thickness: 10 mm) and the slice level was set at the mid-point between the origin and insertion of the masseter. Intramuscular haemoglobin (Hb) levels and water content of the right masseter muscle were continuously monitored for 2 min before, 30 s during and 15 min after a maximum voluntary clenching (MVC) task. Both the near-infrared and MRI data were baseline-corrected and normalized and mean levels were established and plotted. Plots of the data showed that both near-infrared-based total Hb and T(2)-weighted MRI-based signal-intensity levels clearly decreased during contraction and a clear post-contraction rebound response was evident after the contraction. The near-infrared data were found to be highly correlated with MRI-based signal-intensity data (Pearson's r=0.909, P<0.0001). In conclusion, these data provide powerful evidence that near-infrared data (total Hb), transcutaneously taken from the masseter muscle in humans, will reflect the intramuscular water signal intensity changes seen using a T(2)-weighted MRI imaging method.

  19. A Comparison of Ultrasonography, Computerised Tomography, and Conventional MRI Findings for Splenic Nodules Associated with Type 1 Gaucher’s Disease with Diffusion-Weighted MRI Findings

    PubMed Central

    Albayrak, Eda; Sonmezgoz, Fitnet; Ozmen, Zafer; Aktas, Fatma; Altunkas, Aysegul

    2017-01-01

    A 26-year-old female patient with Type 1 Gaucher’s disease (GD) was admitted to our clinic with complaints of stomachache and signs of anemia. The patient underwent ultrasonography (US), computerised tomography (CT), and magnetic resonance imaging (MRI) scan. Imaging studies revealed massive hepatosplenomegaly, choledocolithiasis, and six nodules in the spleen with a mean size of 14 mm. The nodules appeared hyperechoic, hypoechoic, and of mixed echogenicity on the US and hypodense on the CT. While the nodules were observed to be iso-hypointense in T1-weighted (T1WI) images, they appeared to be hyperintense in the T2-weighted (T2WI) images. There were no diffusion restrictions in these nodules that appeared on the diffusion-weighted magnetic resonance imaging (DWI). A nodule located at the lower pole was observed to be hypointense in the T2WI images. The nodule located at the lower pole, which appeared hypointense in T2WI series, had restricted diffusion upon DWI. In this study, we aimed to present the properties of splenic GD nodules using US, CT, and conventional MRI, together with DWI. This case report is the first to apply US, CT, and conventional MRI, together with DWI, to the splenic nodules associated with Gaucher’s disease. PMID:29386979

  20. In vivo High Angular Resolution Diffusion-Weighted Imaging of Mouse Brain at 16.4 Tesla

    PubMed Central

    Alomair, Othman I.; Brereton, Ian M.; Smith, Maree T.; Galloway, Graham J.; Kurniawan, Nyoman D.

    2015-01-01

    Magnetic Resonance Imaging (MRI) of the rodent brain at ultra-high magnetic fields (> 9.4 Tesla) offers a higher signal-to-noise ratio that can be exploited to reduce image acquisition time or provide higher spatial resolution. However, significant challenges are presented due to a combination of longer T 1 and shorter T 2/T2* relaxation times and increased sensitivity to magnetic susceptibility resulting in severe local-field inhomogeneity artefacts from air pockets and bone/brain interfaces. The Stejskal-Tanner spin echo diffusion-weighted imaging (DWI) sequence is often used in high-field rodent brain MRI due to its immunity to these artefacts. To accurately determine diffusion-tensor or fibre-orientation distribution, high angular resolution diffusion imaging (HARDI) with strong diffusion weighting (b >3000 s/mm2) and at least 30 diffusion-encoding directions are required. However, this results in long image acquisition times unsuitable for live animal imaging. In this study, we describe the optimization of HARDI acquisition parameters at 16.4T using a Stejskal-Tanner sequence with echo-planar imaging (EPI) readout. EPI segmentation and partial Fourier encoding acceleration were applied to reduce the echo time (TE), thereby minimizing signal decay and distortion artefacts while maintaining a reasonably short acquisition time. The final HARDI acquisition protocol was achieved with the following parameters: 4 shot EPI, b = 3000 s/mm2, 64 diffusion-encoding directions, 125×150 μm2 in-plane resolution, 0.6 mm slice thickness, and 2h acquisition time. This protocol was used to image a cohort of adult C57BL/6 male mice, whereby the quality of the acquired data was assessed and diffusion tensor imaging (DTI) derived parameters were measured. High-quality images with high spatial and angular resolution, low distortion and low variability in DTI-derived parameters were obtained, indicating that EPI-DWI is feasible at 16.4T to study animal models of white matter (WM

  1. [Diffusion weighted imaging and perfusion weighted imaging in the differential diagnosis of benign and malignant renal masses on 3.0 T MRI].

    PubMed

    Xu, Xiaowen; Wang, Peijun; Ma, Liang; Shao, Zhihong; Zhang, Min

    2015-01-20

    To explore the value of diffusion weighted imaging (DWI) and perfusion weighted imaging (PWI) in identifying benign and malignant renal masses and differentiating the histological types of renal masses. Fifteen healthy volunteers and 46 patients with renal masses proven by pathology, including clear cell carcinomas (n = 18), papillary carcinomas (n = 8), chromophobe carcinomas (n = 7) and angiomyolipomas (n = 13), were examined with DWI and PWI scan at 3.0 T MRI. ANOVA was employed to compare the values of transfer constant (K(trans)), rate constant of backflux (Kep) and extra-vascular extra-cellular space fractional volume (Ve) proceeded by PWI and the value of ADC resulted from DWI between normal kidney and different histological types of renal masses. Receiver operating characteristics (ROC) curve was used to analyze and compare the diagnostic value of the methods of PWI and DWI in differentiating benign and malignant renal masses. The ADC value of normal renal parenchyma was (2.10 ± 0.24) × 10⁻³ mm²/s, which was statistically higher than benign and malignant renal masses (P < 0.05). The ADC value of benign masses was statistically higher than that of all histological types of malignant masses (P < 0.05). Among three histological types of malignancies, clear cell carcinoma showed the statistically highest ADC value (P < 0.05). But the difference between papillary carcinoma and chromophobe carcinoma had no statistical significance (P > 0.05).Values of K(trans), Kep and Ve between normal renal parenchyma and different histological types of renal masses had statistical differences.Values of K(trans) and Ve in three histological types of malignant renal masses were statistically higher than those of benign renal masses.Kep value of clear cell carcinoma was significantly higher than that of benign renal masses (P < 0.05).However, other histological types of malignant masses had no significant difference with benign masses.For three malignant masses, K(trans) of

  2. Usefulness of IDEAL T2 imaging for homogeneous fat suppression and reducing susceptibility artefacts in brachial plexus MRI at 3.0 T.

    PubMed

    Tagliafico, Alberto; Bignotti, Bianca; Tagliafico, Giulio; Martinoli, Carlo

    2016-01-01

    To quantitatively and qualitatively compare fat-suppressed MR imaging quality using iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) with that using frequency-selective fat-suppressed (FSFS) T2 images of the brachial plexus at 3.0 T. Prospective MR image analysis was performed in 40 volunteers and 40 patients at a single centre. Oblique-sagittal and coronal IDEAL fat-suppressed T2 images and FSFS T2 images were compared. Visual assessment was performed by two independent musculoskeletal radiologists with respect to: (1) susceptibility artefacts around the neck, (2) homogeneity of fat suppression, (3) image sharpness and (4) tissue resolution contrast of pathologies. The signal-to-noise ratios (SNR) for each image sequence were assessed. Compared to FSFS sequences, IDEAL fat-suppressed T2 images significantly reduced artefacts around the brachial plexus and significantly improved homogeneous fat suppression (p < 0.05). IDEAL significantly improved sharpness and lesion-to-tissue contrast (p < 0.05). The mean SNRs were significantly improved on T2-weighted IDEAL images (p < 0.05). IDEAL technique improved image quality by reducing artefacts around the brachial plexus while maintaining a high SNR and provided superior homogeneous fat suppression than FSFS sequences.

  3. Assessment of Arterial Wall Enhancement for Differentiation of Parent Artery Disease from Small Artery Disease: Comparison between Histogram Analysis and Visual Analysis on 3-Dimensional Contrast-Enhanced T1-Weighted Turbo Spin Echo MR Images at 3T.

    PubMed

    Jang, Jinhee; Kim, Tae-Won; Hwang, Eo-Jin; Choi, Hyun Seok; Koo, Jaseong; Shin, Yong Sam; Jung, So-Lyung; Ahn, Kook-Jin; Kim, Bum-Soo

    2017-01-01

    The purpose of this study was to compare the histogram analysis and visual scores in 3T MRI assessment of middle cerebral arterial wall enhancement in patients with acute stroke, for the differentiation of parent artery disease (PAD) from small artery disease (SAD). Among the 82 consecutive patients in a tertiary hospital for one year, 25 patients with acute infarcts in middle cerebral artery (MCA) territory were included in this study including 15 patients with PAD and 10 patients with SAD. Three-dimensional contrast-enhanced T1-weighted turbo spin echo MR images with black-blood preparation at 3T were analyzed both qualitatively and quantitatively. The degree of MCA stenosis, and visual and histogram assessments on MCA wall enhancement were evaluated. A statistical analysis was performed to compare diagnostic accuracy between qualitative and quantitative metrics. The degree of stenosis, visual enhancement score, geometric mean (GM), and the 90th percentile (90P) value from the histogram analysis were significantly higher in PAD than in SAD ( p = 0.006 for stenosis, < 0.001 for others). The receiver operating characteristic curve area of GM and 90P were 1 (95% confidence interval [CI], 0.86-1.00). A histogram analysis of a relevant arterial wall enhancement allows differentiation between PAD and SAD in patients with acute stroke within the MCA territory.

  4. Chondromalacia patellae: diagnosis with MR imaging.

    PubMed

    McCauley, T R; Kier, R; Lynch, K J; Jokl, P

    1992-01-01

    Most previous studies of MR imaging for detection of chondromalacia have used T1-weighted images. We correlated findings on axial MR images of the knee with arthroscopic findings to determine MR findings of chondromalacia patellae on T2-weighted and proton density-weighted images. The study population included 52 patients who had MR examination of the knee with a 1.5-T unit and subsequent arthroscopy, which documented chondromalacia patellae in 29 patients and normal cartilage in 23. The patellar cartilage was assessed retrospectively for MR signal and contour characteristics. MR diagnosis based on the criteria of focal signal or focal contour abnormality on either the T2-weighted or proton density-weighted images yielded the highest correlation with the arthroscopic diagnosis of chondromalacia. When these criteria were used, patients with chondromalacia were detected with 86% sensitivity, 74% specificity, and 81% accuracy. MR diagnosis based on T2-weighted images alone was more sensitive and accurate than was diagnosis based on proton density-weighted images alone. In conclusion, most patients with chondromalacia patellae have focal signal or focal contour defects in the patellar cartilage on T2-weighted MR images. These findings are absent in most patients with arthroscopically normal cartilage.

  5. Acute interstitial edematous pancreatitis: Findings on non-enhanced MR imaging

    PubMed Central

    Zhang, Xiao-Ming; Feng, Zhi-Song; Zhao, Qiong-Hui; Xiao, Chun-Ming; Mitchell, Donald G; Shu, Jian; Zeng, Nan-Lin; Xu, Xiao-Xue; Lei, Jun-Yang; Tian, Xiao-Bing

    2006-01-01

    AIM: To study the appearances of acute interstitial edematous pancreatitis (IEP) on non-enhanced MR imaging. METHODS: A total of 53 patients with IEP diagnosed by clinical features and laboratory findings were underwent MR imaging. MR imaging sequences included fast spoiled gradient echo (FSPGR) fat saturation axial T1-weighted imaging, gradient echo T1-weighted (in phase), single shot fast spin echo (SSFSE) T2-weighted, respiratory triggered (R-T) T2-weighted with fat saturation, and MR cholangiopancreatography. Using the MR severity score index, pancreatitis was graded as mild (0-2 points), moderate (3-6 points) and severe (7-10 points). RESULTS: Among the 53 patients, IEP was graded as mild in 37 patients and as moderate in 16 patients. Forty-seven of 53 (89%) patients had at least one abnormality on MR images. Pancreas was hypointense relative to liver on FSPGR T1-weighted images in 18.9% of patients, and hyperintense in 25% and 30% on SSFSE T2-weighted and R-T T2-weighted images, respectively. The prevalences of the findings of IEP on R-T T2-weighted images were, respectively, 85% for pancreatic fascial plane, 77% for left renal fascial plane, 55% for peripancreatic fat stranding, 42% for right renal fascial plane, 45% for perivascular fluid, 40% for thickened pancreatic lobular septum and 25% for peripancreatic fluid, which were markedly higher than those on in-phase or SSFSE T2-weighted images (P < 0.001). CONCLUSION: IEP primarily manifests on non-enhanced MR images as thickened pancreatic fascial plane, left renal fascial plane, peripancreatic fat stranding, and peripancreatic fluid. R-T T2-weighted imaging is more sensitive than in-phase and SSFSE T2-weighted imaging for depicting IEP. PMID:17007053

  6. Acute interstitial edematous pancreatitis: Findings on non-enhanced MR imaging.

    PubMed

    Zhang, Xiao-Ming; Feng, Zhi-Song; Zhao, Qiong-Hui; Xiao, Chun-Ming; Mitchell, Donald-G; Shu, Jian; Zeng, Nan-Lin; Xu, Xiao-Xue; Lei, Jun-Yang; Tian, Xiao-Bing

    2006-09-28

    To study the appearances of acute interstitial edematous pancreatitis (IEP) on non-enhanced MR imaging. A total of 53 patients with IEP diagnosed by clinical features and laboratory findings were underwent MR imaging. MR imaging sequences included fast spoiled gradient echo (FSPGR) fat saturation axial T1-weighted imaging, gradient echo T1-weighted (in phase), single shot fast spin echo (SSFSE) T2-weighted, respiratory triggered (R-T) T2-weighted with fat saturation, and MR cholangiopancreatography. Using the MR severity score index, pancreatitis was graded as mild (0-2 points), moderate (3-6 points) and severe (7-10 points). Among the 53 patients, IEP was graded as mild in 37 patients and as moderate in 16 patients. Forty-seven of 53 (89%) patients had at least one abnormality on MR images. Pancreas was hypointense relative to liver on FSPGR T1-weighted images in 18.9% of patients, and hyperintense in 25% and 30% on SSFSE T2-weighted and R-T T2-weighted images, respectively. The prevalences of the findings of IEP on R-T T2-weighted images were, respectively, 85% for pancreatic fascial plane, 77% for left renal fascial plane, 55% for peripancreatic fat stranding, 42% for right renal fascial plane, 45% for perivascular fluid, 40% for thickened pancreatic lobular septum and 25% for peripancreatic fluid, which were markedly higher than those on in-phase or SSFSE T2-weighted images (P<0.001). IEP primarily manifests on non-enhanced MR images as thickened pancreatic fascial plane, left renal fascial plane, peripancreatic fat stranding, and peripancreatic fluid. R-T T2-weighted imaging is more sensitive than in-phase and SSFSE T2-weighted imaging for depicting IEP.

  7. T1 bright appendix sign to exclude acute appendicitis in pregnant women.

    PubMed

    Shin, Ilah; An, Chansik; Lim, Joon Seok; Kim, Myeong-Jin; Chung, Yong Eun

    2017-08-01

    To evaluate the diagnostic value of the T1 bright appendix sign for the diagnosis of acute appendicitis in pregnant women. This retrospective study included 125 pregnant women with suspected appendicitis who underwent magnetic resonance (MR) imaging. The T1 bright appendix sign was defined as a high intensity signal filling more than half length of the appendix on T1-weighted imaging. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the T1 bright appendix sign for normal appendix identification were calculated in all patients and in those with borderline-sized appendices (6-7 mm). The T1 bright appendix sign was seen in 51% of patients with normal appendices, but only in 4.5% of patients with acute appendicitis. The overall sensitivity, specificity, PPV, and NPV of the T1 bright appendix sign for normal appendix diagnosis were 44.9%, 95.5%, 97.6%, and 30.0%, respectively. All four patients with borderline sized appendix with appendicitis showed negative T1 bright appendix sign. The T1 bright appendix sign is a specific finding for the diagnosis of a normal appendix in pregnant women with suspected acute appendicitis. • Magnetic resonance imaging is increasingly used in emergency settings. • Acute appendicitis is the most common cause of acute abdomen. • Magnetic resonance imaging is widely used in pregnant population. • T1 bright appendix sign can be a specific sign representing normal appendix.

  8. Clinical equivalence assessment of T2 synthesized pediatric brain magnetic resonance imaging.

    PubMed

    Kerleroux, Basile; Kober, Tobias; Hilbert, Tom; Serru, Maxence; Sirinelli, Dominique; Morel, Baptiste

    2018-05-04

    Automated synthetic magnetic resonance imaging (MRI) provides qualitative, weighted image contrasts as well as quantitative information from one scan and is well-suited for various applications such as analysis of white matter disorders. However, the synthesized contrasts have been poorly evaluated in pediatric applications. The purpose of this study was to compare the image quality of synthetic T2 to conventional turbo spin echo (TSE) T2 in pediatric brain MRI. This was a mono-center prospective study. Synthetic and conventional MRI acquisitions at 1.5 Tesla were performed for each patient during the same session using a prototype accelerated T2 mapping sequence package (TA synthetic =3:07min, TA conventional =2:33min). Image sets were blindly and randomly analyzed by pediatric neuro-radiologists. Global image quality, morphologic legibility of standard structures and artifacts were assessed using a 4-point Likert scale. Inter-observer kappa agreements were calculated. The capability of the synthesized contrasts and conventional TSE T2 to discern normal and pathologic cases was evaluated. Sixty patients were included. The overall diagnostic quality of the synthesized contrasts was non-inferior to conventional imaging scale (p=0.06). There was no significant difference in the legibility of normal and pathological anatomic structures of synthetized and conventional TSE T2 (all p > 0.05) as well as for artifacts except for phase encoding (p=0.008). Interobserver agreement was good to almost perfect (kappa between 0.66 and 1). T2 synthesized contrasts, which also provides quantitative T2 information that could be useful, could be suggested as an equivalent technique in pediatric neuro-imaging, compared to conventional TSE T2. Copyright © 2018. Published by Elsevier Masson SAS.

  9. Correlation Between Expression of High Temperature Requirement Serine Protease A1 (HtrA1) in Nucleus Pulposus and T2 Value of Magnetic Resonance Imaging.

    PubMed

    Li, Dapeng; Yue, Jiawei; Jiang, Lu; Huang, Yonghui; Sun, Jifu; Wu, Yan

    2017-04-22

    BACKGROUND Degrading enzymes play an important role in the process of disc degeneration. The objective of this study was to investigate the correlation between the expression of high temperature requirement serine protease A1 (HtrA1) in the nucleus pulposus and the T2 value of the nucleus pulposus region in magnetic resonance imaging (MRI). MATERIAL AND METHODS Thirty-six patients who had undergone surgical excision of the nucleus pulposus were examined by MRI before surgery. Pfirrmann grading of the target intervertebral disc was performed according to the sagittal T2-weighted imaging, and the T2 value of the target nucleus pulposus was measured according to the median sagittal T2 mapping. The correlation between the Pfirrmann grade and the T2 value was analyzed. The expression of HtrA1 in the nucleus pulposus was analyzed by RT-PCR and Western blot. The correlation between the expression of HtrA1 and the T2 value was analyzed. RESULTS The T2 value of the nucleus pulposus region was 33.11-167.91 ms, with an average of 86.64±38.73 ms. According to Spearman correlation analysis, there was a rank correlation between T2 value and Pfirrmann grade (P<0.0001), and the correlation coefficient (rs)=-0.93617. There was a linear correlation between the mRNA level of HtrA1 and T2 value in nucleus pulposus tissues (a=3.88, b=-0.019, F=112.63, P<0.0001), normalized regression coefficient=-0.88. There was a linear correlation between the expression level of HtrA1 protein and the T2 value in the nucleus pulposus tissues (a=3.30, b=-0.016, F=93.15, P<0.0001) and normalized regression coefficient=-0.86. CONCLUSIONS The expression of HtrA1 was strongly related to the T2 value, suggesting that HtrA1 plays an important role in the pathological process of intervertebral disc degeneration.

  10. Effect of body image on pregnancy weight gain.

    PubMed

    Mehta, Ushma J; Siega-Riz, Anna Maria; Herring, Amy H

    2011-04-01

    The majority of women gain more weight during pregnancy than what is recommended. Since gestational weight gain is related to short and long-term maternal health outcomes, it is important to identify women at greater risk of not adhering to guidelines. The objective of this study was to examine the relationship between body image and gestational weight gain. The Body Image Assessment for Obesity tool was used to measure ideal and current body sizes in 1,192 women participating in the Pregnancy, Infection and Nutrition Study. Descriptive and multivariable techniques were used to assess the effects of ideal body size and discrepancy score (current-ideal body sizes), which reflected the level of body dissatisfaction, on gestational weight gain. Women who preferred to be thinner had increased risk of excessive gain if they started the pregnancy at a BMI ≤26 kg/m(2) but a decreased risk if they were overweight or obese. Comparing those who preferred thin body silhouettes to those who preferred average size silhouettes, low income women had increased risk of inadequate weight gain [RR = 1.76 (1.08, 2.88)] while those with lower education were at risk of excessive gain [RR = 1.11 (1.00, 1.22)]. Our results revealed that body image was associated with gestational weight gain but the relationship is complex. Identifying factors that affect whether certain women are at greater risk of gaining outside of guidelines may improve our ability to decrease pregnancy-related health problems.

  11. Diffusion-weighted imaging in pediatric body MR imaging: principles, technique, and emerging applications.

    PubMed

    Chavhan, Govind B; Alsabban, Zehour; Babyn, Paul S

    2014-01-01

    Diffusion-weighted (DW) imaging is an emerging technique in body imaging that provides indirect information about the microenvironment of tissues and lesions and helps detect, characterize, and follow up abnormalities. Two main challenges in the application of DW imaging to body imaging are the decreased signal-to-noise ratio of body tissues compared with neuronal tissues due to their shorter T2 relaxation time, and image degradation related to physiologic motion (eg, respiratory motion). Use of smaller b values and newer motion compensation techniques allow the evaluation of anatomic structures with DW imaging. DW imaging can be performed as a breath-hold sequence or a free-breathing sequence with or without respiratory triggering. Depending on the mobility of water molecules in their microenvironment, different normal tissues have different signals at DW imaging. Some normal tissues (eg, lymph nodes, spleen, ovarian and testicular parenchyma) are diffusion restricted, whereas others (eg, gallbladder, corpora cavernosa, endometrium, cartilage) show T2 shine-through. Epiphyses that contain fatty marrow and bone cortex appear dark on both DW images and apparent diffusion coefficient maps. Current and emerging applications of DW imaging in pediatric body imaging include tumor detection and characterization, assessment of therapy response and monitoring of tumors, noninvasive detection and grading of liver fibrosis and cirrhosis, detection of abscesses, and evaluation of inflammatory bowel disease. RSNA, 2014

  12. 3T diffusion-weighted MRI of the thyroid gland with reduced distortion: preliminary results

    PubMed Central

    Nagala, S; Priest, A N; McLean, M A; Jani, P; Graves, M J

    2013-01-01

    Objective: Single-shot diffusion-weighted (DW) echo planar imaging (EPI), which is commonly used for imaging the thyroid, is characterised by severe blurring and distortion. The objectives of this work were: 1, to show that a reduced-field of view (r-FOV) DW EPI technique can improve image quality; and 2, to investigate the effect of different reconstruction strategies on the resulting apparent diffusion coefficients (ADCs). Methods: We implemented a single-shot, r-FOV DW EPI technique with a two-dimensional radiofrequency excitation pulse for DW imaging of the thyroid at 3T. Images were reconstructed using root sum of squares (SOS) and an optimal-B1 reconstruction (OBR). Phantom and in vivo experiments were performed to compare r-FOV and conventional full-FOV DW EPI with root SOS and OBR. Results: r-FOV with OBR substantially improved image quality at 3T. In phantoms, r-FOV gave more accurate ADCs than full-FOV. In vivo r-FOV always gave lower ADC values with respect to the full-FOV technique irrespective of the reconstruction used and whether only two or multiple b-values were used to compute the ADCs. Conclusion: r-FOV DW EPI can reduce image blurring and distortion at the expense of a low signal-to-noise ratio. OBR is a promising reconstruction technique for accurate ADC measurements in lower signal-to-noise ratio regimes, although further studies are needed to characterise its performance. Advances in knowledge: DW imaging of the thyroid at 3T could potentially benefit from r-FOV acquisition strategies, such as the r-FOV DW EPI technique proposed in this paper. PMID:23770539

  13. Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla.

    PubMed

    Fallah, Faezeh; Machann, Jürgen; Martirosian, Petros; Bamberg, Fabian; Schick, Fritz; Yang, Bin

    2017-04-01

    To evaluate and compare conventional T1-weighted 2D turbo spin echo (TSE), T1-weighted 3D volumetric interpolated breath-hold examination (VIBE), and two-point 3D Dixon-VIBE sequences for automatic segmentation of visceral adipose tissue (VAT) volume at 3 Tesla by measuring and compensating for errors arising from intensity nonuniformity (INU) and partial volume effects (PVE). The body trunks of 28 volunteers with body mass index values ranging from 18 to 41.2 kg/m 2 (30.02 ± 6.63 kg/m 2 ) were scanned at 3 Tesla using three imaging techniques. Automatic methods were applied to reduce INU and PVE and to segment VAT. The automatically segmented VAT volumes obtained from all acquisitions were then statistically and objectively evaluated against the manually segmented (reference) VAT volumes. Comparing the reference volumes with the VAT volumes automatically segmented over the uncorrected images showed that INU led to an average relative volume difference of -59.22 ± 11.59, 2.21 ± 47.04, and -43.05 ± 5.01 % for the TSE, VIBE, and Dixon images, respectively, while PVE led to average differences of -34.85 ± 19.85, -15.13 ± 11.04, and -33.79 ± 20.38 %. After signal correction, differences of -2.72 ± 6.60, 34.02 ± 36.99, and -2.23 ± 7.58 % were obtained between the reference and the automatically segmented volumes. A paired-sample two-tailed t test revealed no significant difference between the reference and automatically segmented VAT volumes of the corrected TSE (p = 0.614) and Dixon (p = 0.969) images, but showed a significant VAT overestimation using the corrected VIBE images. Under similar imaging conditions and spatial resolution, automatically segmented VAT volumes obtained from the corrected TSE and Dixon images agreed with each other and with the reference volumes. These results demonstrate the efficacy of the signal correction methods and the similar accuracy of TSE and Dixon imaging for automatic volumetry of VAT at 3 Tesla.

  14. TU-EF-BRA-02: Longitudinal Proton Spin Relaxation and T1-Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lemen, L.

    NMR, and Proton Density MRI of the 1D Patient - Anthony Wolbarst Net Voxel Magnetization, m(x,t). T1-MRI; The MRI Device - Lisa Lemen ‘Classical’ NMR; FID Imaging in 1D via k-Space - Nathan Yanasak Spin-Echo; S-E/Spin Warp in a 2D Slice - Ronald Price Magnetic resonance imaging not only reveals the structural, anatomic details of the body, as does CT, but also it can provide information on the physiological status and pathologies of its tissues, like nuclear medicine. It can display high-quality slice and 3D images of organs and vessels viewed from any perspective, with resolution better than 1 mm.more » MRI is perhaps most extraordinary and notable for the plethora of ways in which it can create unique forms of image contrast, reflective of fundamentally different biophysical phenomena. As with ultrasound, there is no risk from ionizing radiation to the patient or staff, since no X-rays or radioactive nuclei are involved. Instead, MRI harnesses magnetic fields and radio waves to probe the stable nuclei of the ordinary hydrogen atoms (isolated protons) occurring in water and lipid molecules within and around cells. MRI consists, in essence, of creating spatial maps of the electromagnetic environments around these hydrogen nuclei. Spatial variations in the proton milieus can be related to clinical differences in the biochemical and physiological properties and conditions of the associated tissues. Imaging of proton density (PD), and of the tissue proton spin relaxation times known as T1 and T2, all can reveal important clinical information, but they do so with approaches so dissimilar from one another that each is chosen for only certain clinical situations. T1 and T2 in a voxel are determined by different aspects of the rotations and other motions of the water and lipid molecules involved, as constrained by the local biophysical surroundings within and between its cells – and they, in turn, depend on the type of tissue and its state of health. Three other

  15. Microbleeds in postmortem brains of patients with Alzheimer disease: a T2*-weighted gradient-echo 7.0 T magnetic resonance imaging study.

    PubMed

    De Reuck, Jacques L; Cordonnier, Charlotte; Deramecourt, Vincent; Auger, Florent; Durieux, Nicolas; Bordet, Regis; Maurage, Claude-Alain; Leys, Didier; Pasquier, Florence

    2013-01-01

    This study aims to determine the distribution and to quantify microbleeds (MBs) in postmortem brains of patients with Alzheimer disease (AD) on T2*-weighted gradient-echo 7.0 T magnetic resonance imaging. Twenty-eight AD brains were compared with 5 controls. The AD brains were subdivided further: 18 without and 10 with additional severe cerebral amyloid angiopathy (AD-CAA). The distribution and the number of cortical focal signal intensity losses, representing MBs, were assessed on coronal sections at the frontal, the central, and the occipital level of a cerebral hemisphere. MBs prevailed in the central sections (P=0.005) of AD brains without CAA, whereas in AD-CAA brains, they were more frequent in all coronal sections (P≤0.002). They prevailed in the deep cortical layers of the AD brains and of the controls (P≤0.03). They were significantly increased in all cortical layers of the AD-CAA brains (P≤0.04), compared with the controls. MBs prevalence in brains of AD patients had a different topographic distribution according to the absence or presence of severe CAA.

  16. 3D Ultrashort TE MRI for Evaluation of Cartilaginous Endplate of Cervical Disk In Vivo: Feasibility and Correlation With Disk Degeneration in T2-Weighted Spin-Echo Sequence.

    PubMed

    Kim, Yeo Ju; Cha, Jang Gyu; Shin, Yoon Sang; Chaudhari, Akshay S; Suh, Young Ju; Hwan Yoon, Seung; Gold, Garry E

    2018-05-01

    The purpose of this study was to evaluate the feasibility of 3D ultrashort TE (UTE) MRI in depicting the cartilaginous endplate (CEP) and its abnormalities and to investigate the association between CEP abnormalities and disk degeneration on T2-weighted spin-echo (SE) MR images in cervical disks in vivo. Eight healthy volunteers and 70 patients were examined using 3-T MRI with the 3D UTE cones trajectory technique (TR/TE, 16.1/0.032, 6.6). In the volunteer study, quantitative and qualitative assessments of CEP depiction were conducted for the 3D UTE and T2-weighted SE imaging. In the patient study, CEP abnormalities were analyzed. Intersequence agreement between the images obtained with the first-echo 3D UTE sequence and the images created by subtracting the second-echo from the first-echo 3D UTE sequence (subtracted 3D UTE) and the intraobserver and interobserver agreements for 3D UTE overall were also tested. The CEP abnormalities on the 3D UTE images correlated with the Miyazaki grading of the T2-weighted SE images. In the volunteer study, the CEP was well visualized on 3D UTE images but not on T2-weighted SE images (p < 0.001). In the patient study, for evaluation of CEP abnormalities, intersequence agreements were substantial to almost perfect, intraobserver agreements were substantial to almost perfect, and interobserver agreements were moderate to substantial (p < 0.001). All of the CEP abnormalities correlated with the Miyazaki grade with statistical significance (p < 0.001). Three-dimensional UTE MRI feasibly depicts the CEP and CEP abnormalities, which may be associated with the severity of disk degeneration on T2-weighted SE MRI.

  17. Inorganic nanoparticle-based T1 and T1/T2 magnetic resonance contrast probes

    NASA Astrophysics Data System (ADS)

    Hu, Fengqin; Zhao, Yong Sheng

    2012-09-01

    Magnetic resonance imaging (MRI) yields high spatially resolved contrast with anatomical details for diagnosis, deeper penetration depth and rapid 3D scanning. To improve imaging sensitivity, adding contrast agents accelerates the relaxation rate of water molecules, thereby greatly increasing the contrast between specific issues or organs of interest. Currently, the majority of T1 contrast agents are paramagnetic molecular complexes, typically Gd(iii) chelates. Various nanoparticulate T1 and T1/T2 contrast agents have recently been investigated as novel agents possessing the advantages of both the T1 contrast effect and nanostructural characteristics. In this minireview, we describe the recent progress of these inorganic nanoparticle-based MRI contrast agents. Specifically, we mainly report on Gd and Mn-based inorganic nanoparticles and ultrasmall iron oxide/ferrite nanoparticles.

  18. Cerebral signal intensity abnormalities on T2-weighted MR images in HIV patients with highly active antiretroviral therapy: relationship with clinical parameters and interval changes.

    PubMed

    Hanning, Uta; Husstedt, Ingo W; Niederstadt, Thomas-Ulrich; Evers, Stefan; Heindel, Walter; Kloska, Stephan P

    2011-09-01

    The aim of this study was to assess the relationship between immune state and cerebral signal intensity abnormalities (SIAs) on T2-weighted magnetic resonance images in subjects with human immunodeficiency virus type 1 infection and highly active antiretroviral therapy. Thirty-two subjects underwent a total of 109 magnetic resonance studies. The presence of human immunodeficiency virus-associated neurocognitive disorder, categorized CD4(+) T lymphocyte count, and plasma viral load were assessed for relationship with the severity and interval change of SIAs for different anatomic locations of the brain. Subjects with multifocal patterns of SIAs had CD4(+) cell counts < 200 cells/μL in 66.0%, whereas subjects with diffuse patterns of SIAs had CD4(+) cell counts < 200 cells/μL in only 31.4% (P < .001). Subjects without SIAs in the basal ganglia had CD4(+) cell counts < 200 cells/μL in 37.0%, whereas subjects with minor and moderate SIAs in the basal ganglia had CD4(+) cell counts < 200 cells/μL in 78.3% and 80.0%, respectively (P < .005). The percentage of subjects with CD4(+) cell counts < 200 cells/μL was 85.7% when there were progressive periventricular SIA changes and 45.5% when periventricular SIA changes were stable in follow-up (P < .05). The presence and progression of cerebral SIAs on T2-weighted magnetic resonance images reflecting cerebral infection with human immunodeficiency virus are significantly related to impaired immune state as measured by CD4(+) cell count. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  19. [Visualization of Anterolateral Ligament of the Knee Using 3D Reconstructed Variable Refocus Flip Angle-Turbo Spin Echo T2 Weighted Image].

    PubMed

    Yokosawa, Kenta; Sasaki, Kana; Muramatsu, Koichi; Ono, Tomoya; Izawa, Hiroyuki; Hachiya, Yudo

    2016-05-01

    Anterolateral ligament (ALL) is one of the lateral structures in the knee that contributes to the internal rotational stability of tibia. ALL has been referred to in some recent reports to re-emphasize its importance. We visualized the ALL on 3D-MRI in 32 knees of 27 healthy volunteers (23 male knees, 4 female knees; mean age: 37 years). 3D-MRIs were performed using 1.5-T scanner [T(2) weighted image (WI), SPACE: Sampling Perfection with Application optimized Contrast using different flip angle Evolutions] in the knee extended positions. The visualization rate of the ALL, the mean angle to the lateral collateral ligament (LCL), and the width and the thickness of the ALL at the joint level were investigated. The visualization rate was 100%. The mean angle to the LCL was 10.6 degrees. The mean width and the mean thickness of the ALL were 6.4 mm and 1.0 mm, respectively. The ALL is a very thin ligament with a somewhat oblique course between the lateral femoral epicondyle and the mid-third area of lateral tibial condyle. Therefore, the slice thickness and the slice angle can easily affect the ALL visualization. 3D-MRI enables acquiring thin-slice imaging data over a relatively short time, and arbitrary sections aligned with the course of the ALL can later be selected.

  20. Quantification of hepatic steatosis with T1-independent, T2-corrected MR imaging with spectral modeling of fat: blinded comparison with MR spectroscopy.

    PubMed

    Meisamy, Sina; Hines, Catherine D G; Hamilton, Gavin; Sirlin, Claude B; McKenzie, Charles A; Yu, Huanzhou; Brittain, Jean H; Reeder, Scott B

    2011-03-01

    To prospectively compare an investigational version of a complex-based chemical shift-based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24-71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r(2)), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2 correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction were used (r(2

  1. Biochemical magnetic resonance imaging of knee articular cartilage: T1rho and T2 mapping as cartilage degeneration biomarkers.

    PubMed

    Le, Jenna; Peng, Qi; Sperling, Karen

    2016-11-01

    Osteoarthritis (OA) is a disease whose hallmark is the degeneration of articular cartilage. There is a worsening epidemic of OA in the United States today, with considerable economic costs. In order to develop more effective treatments for OA, noninvasive biomarkers that permit early diagnosis and treatment monitoring are necessary. T1rho and T2 mapping are two magnetic resonance imaging techniques that have shown great promise as noninvasive biomarkers of cartilage degeneration. Each of the two techniques is endowed with advantages and disadvantages: T1rho can discern earlier biochemical changes of OA than T2 mapping, while T2 mapping is more widely available and can be incorporated into existing imaging protocols in a more time-efficient manner than T1rho. Both techniques have been applied in numerous instances to study how cartilage is affected by OA risk factors, such as age and exercise. Additionally, both techniques have been repeatedly applied to the study of posttraumatic OA in patients with torn anterior cruciate ligaments. © 2016 New York Academy of Sciences.

  2. Fetal intracranial hemorrhage. Imaging by ultrasound and magnetic resonance imaging.

    PubMed

    Kirkinen, P; Partanen, K; Ryynänen, M; Ordén, M R

    1997-08-01

    To describe the magnetic resonance imaging (MRI) findings associated with fetal intracranial hemorrhage and to compare them with ultrasound findings. In four pregnancies complicated by fetal intracranial hemorrhage, fetal imaging was carried out using T2-weighted fast spin echo sequences and T1-weighted fast low angle shot imaging sequences and by transabdominal ultrasonography. An antepartum diagnosis of hemorrhage was made by ultrasound in one case and by MRI in two. Retrospectively, the hemorrhagic area could be identified from the MRI images in an additional two cases and from the ultrasound images in one case. In the cases of intraventricular hemorrhage, the MRI signal intensity in the T1-weighted images was increased in the hemorrhagic area as compared to the contralateral ventricle and brain parenchyma. In a case with subdural hemorrhage, T2-weighted MRI signals from the hemorrhagic area changed from low-to high-intensity signals during four weeks of follow-up. Better imaging of the intracranial anatomy was possible by MRI than by transabdominal ultrasonography. MRI can be used for imaging and dating fetal intracranial hemorrhages. Variable ultrasound and MRI findings are associated with this complication, depending on the age and location of the hemorrhage.

  3. Rapid Parametric Mapping of the Longitudinal Relaxation Time T1 Using Two-Dimensional Variable Flip Angle Magnetic Resonance Imaging at 1.5 Tesla, 3 Tesla, and 7 Tesla

    PubMed Central

    Dieringer, Matthias A.; Deimling, Michael; Santoro, Davide; Wuerfel, Jens; Madai, Vince I.; Sobesky, Jan; von Knobelsdorff-Brenkenhoff, Florian; Schulz-Menger, Jeanette; Niendorf, Thoralf

    2014-01-01

    Introduction Visual but subjective reading of longitudinal relaxation time (T1) weighted magnetic resonance images is commonly used for the detection of brain pathologies. For this non-quantitative measure, diagnostic quality depends on hardware configuration, imaging parameters, radio frequency transmission field (B1+) uniformity, as well as observer experience. Parametric quantification of the tissue T1 relaxation parameter offsets the propensity for these effects, but is typically time consuming. For this reason, this study examines the feasibility of rapid 2D T1 quantification using a variable flip angles (VFA) approach at magnetic field strengths of 1.5 Tesla, 3 Tesla, and 7 Tesla. These efforts include validation in phantom experiments and application for brain T1 mapping. Methods T1 quantification included simulations of the Bloch equations to correct for slice profile imperfections, and a correction for B1+. Fast gradient echo acquisitions were conducted using three adjusted flip angles for the proposed T1 quantification approach that was benchmarked against slice profile uncorrected 2D VFA and an inversion-recovery spin-echo based reference method. Brain T1 mapping was performed in six healthy subjects, one multiple sclerosis patient, and one stroke patient. Results Phantom experiments showed a mean T1 estimation error of (-63±1.5)% for slice profile uncorrected 2D VFA and (0.2±1.4)% for the proposed approach compared to the reference method. Scan time for single slice T1 mapping including B1+ mapping could be reduced to 5 seconds using an in-plane resolution of (2×2) mm2, which equals a scan time reduction of more than 99% compared to the reference method. Conclusion Our results demonstrate that rapid 2D T1 quantification using a variable flip angle approach is feasible at 1.5T/3T/7T. It represents a valuable alternative for rapid T1 mapping due to the gain in speed versus conventional approaches. This progress may serve to enhance the capabilities of

  4. Rapid parametric mapping of the longitudinal relaxation time T1 using two-dimensional variable flip angle magnetic resonance imaging at 1.5 Tesla, 3 Tesla, and 7 Tesla.

    PubMed

    Dieringer, Matthias A; Deimling, Michael; Santoro, Davide; Wuerfel, Jens; Madai, Vince I; Sobesky, Jan; von Knobelsdorff-Brenkenhoff, Florian; Schulz-Menger, Jeanette; Niendorf, Thoralf

    2014-01-01

    Visual but subjective reading of longitudinal relaxation time (T1) weighted magnetic resonance images is commonly used for the detection of brain pathologies. For this non-quantitative measure, diagnostic quality depends on hardware configuration, imaging parameters, radio frequency transmission field (B1+) uniformity, as well as observer experience. Parametric quantification of the tissue T1 relaxation parameter offsets the propensity for these effects, but is typically time consuming. For this reason, this study examines the feasibility of rapid 2D T1 quantification using a variable flip angles (VFA) approach at magnetic field strengths of 1.5 Tesla, 3 Tesla, and 7 Tesla. These efforts include validation in phantom experiments and application for brain T1 mapping. T1 quantification included simulations of the Bloch equations to correct for slice profile imperfections, and a correction for B1+. Fast gradient echo acquisitions were conducted using three adjusted flip angles for the proposed T1 quantification approach that was benchmarked against slice profile uncorrected 2D VFA and an inversion-recovery spin-echo based reference method. Brain T1 mapping was performed in six healthy subjects, one multiple sclerosis patient, and one stroke patient. Phantom experiments showed a mean T1 estimation error of (-63±1.5)% for slice profile uncorrected 2D VFA and (0.2±1.4)% for the proposed approach compared to the reference method. Scan time for single slice T1 mapping including B1+ mapping could be reduced to 5 seconds using an in-plane resolution of (2×2) mm2, which equals a scan time reduction of more than 99% compared to the reference method. Our results demonstrate that rapid 2D T1 quantification using a variable flip angle approach is feasible at 1.5T/3T/7T. It represents a valuable alternative for rapid T1 mapping due to the gain in speed versus conventional approaches. This progress may serve to enhance the capabilities of parametric MR based lesion detection and

  5. Three-Dimensional Isotropic Fat-Suppressed Proton Density-Weighted MRI at 3 Tesla Using a T/R-Coil Can Replace Multiple Plane Two-Dimensional Sequences in Knee Imaging.

    PubMed

    Homsi, R; Gieseke, J; Luetkens, J A; Kupczyk, P; Maedler, B; Kukuk, G M; Träber, F; Agha, B; Rauch, M; Rajakaruna, N; Willinek, W; Schild, H H; Hadizadeh, D R

    2016-10-01

    To evaluate whether a 3 D proton density-weighted fat-suppressed sequence (PDwFS) of the knee is able to replace multiplanar 2D-PDwFS. 52 patients (26 men, mean age: 41.9 ± 14.5years) underwent magnetic resonance imaging (MRI) of the knee at 3.0 Tesla using a T/R-coil. The imaging protocol included 3 planes of 2D-PDwFS (acquisition time (AT): 6:40 min; voxel sizes: 0.40 - 0.63 × 0.44 - 0.89 × 3mm³) and a 3D-PDwFS (AT: 6:31 min; voxel size: 0.63 × 0.68 × 0.63mm³). Homogeneity of fat suppression (HFS), artifacts, and image sharpness (IS) were evaluated on a 5-point scale (5[excellent] - 1[non-diagnostic]). The sum served as a measure for the overall image quality (OIQ). Contrast ratios (CR) compared to popliteal muscle were calculated for the meniscus (MEN), anterior (ACL) and posterior cruciate ligaments (PCL). In 13 patients who underwent arthroscopic knee surgery, two radiologists evaluated the presence of meniscal, ligamental and cartilage lesions to estimate the sensitivity and specificity of lesion detection. The CR was higher in the ACL, PCL and MEN in 3D- PDwFS compared to 2D-PDwFS (p < 0.01 for ACL and PCL; p = 0.07 for MEN). Compared to 2 D images, the OIQ was rated higher in 3D-PDwFS images (p < 0.01) due to fewer artifacts and HFS despite the lower IS (p < 0.01). The sensitivity and specificity of lesion detection in 3D- and 2D-PDwFS were similar. Compared to standard multiplanar 2D-PDwFS knee imaging, isotropic high spatial resolution 3D-PDwFS of the knee at 3.0 T can be acquired with high image quality in a reasonable scan time. Multiplanar reformations in arbitrary planes may serve as an additional benefit of 3D-PDwFS. • 3D-PDwFS of the knee is acquired with high image quality• 3D-PDwFS can be achieved in only one measurement with a reasonable scan time• 3D-PDwFS with the advantage of multiplanar reformation may replace 2D-PD-weighted knee MRI Citation Format: • Homsi R, Gieseke

  6. Phase sensitive reconstruction of T1-weighted inversion recovery in the evaluation of the cervical cord lesions in multiple Sclerosis; is it similarly eligible in 1.5 T magnet fields?

    PubMed

    Shayganfar, A; Sarrami, A H; Fathi, S; Shaygannejad, V; Shamsian, S

    2018-04-22

    In primary studies with 3 T Magnets, phase sensitive reconstruction of T1-weighted inversion recovery (PSIR) have showed ability to depict the cervical multiple sclerosis (MS) lesions some of which may not be detected by short tau inversion recovery (STIR). Regarding to more availability of 1.5 T MRI, this study was designed to evaluate the eligibility of PSIR in 1.5 T for detection of spinal cord MS lesions. In a study between September 2016 till March 2017 the patients with proven diagnosis of MS enrolled to the study. The standard protocol (sagittal STIR and T2W FSE and axial T2W FSE) as well as sagittal PSIR sequences were performed using a 1.5 T magnet. The images were studied and the lesions were localized and recorded as sharp or faint on each sequence. Of 25 patients (22 females and 3 males, with mean age of 33.5 ± 9.8 years and mean disease duration of 5.4 ± 3.9 years) 69 lesions in STIR, 53 lesions in T2W FSE, 47 lesions in Magnitude reconstruction of PSIR (Magnitude), and 30 lesions in phase sensitive (real) reconstruction PSIR were detected. A Wilcoxon signed-rank test showed STIR has a statistically significant higher detection rate of the plaques rather than other three sequences. (STIR and T2W FSE, Z = -4.000, p < 0.0001, STIR and Magnitude, Z = -4.690, p < 0.0001, STIR and PSIR, Z = -6.245, p = 0.002) Also, STIR had a statistically significant superiority in the boundary definition of the plaques rather than other three sequences. This study shows that in the setting of a 1.5 T magnet field, STIR significantly has a superiority over both of the PSIR reconstructions (i.e. real and magnitude) for the detection as well as the boundary definition of the cervical cord lesions of MS. These results have a good relevance to clinical practice by using MRI scanners and sequences routinely available, however, it is discrepant with other reports performed by 3 T Magnet fields. Copyright © 2018 Elsevier B.V. All rights

  7. The knee: Surface-coil MR imaging at 1. 5 T

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beltran, J.; Noto, A.M.; Mosure, J.C.

    1986-06-01

    Seven normal knees (in five volunteers) and seven injured knees (in seven patients) were examined by high-resolution magnetic resonance (MR) imaging at 1.5 T with a surface coil. Seven medial meniscal tears, three anterior cruciate ligament tears, one posterior cruciate ligament avulsion, an old osteochondral fracture, femoral condylar chondro-malacia, and one case of semimembranous tendon reinsertion were identified. MR images correlated well with recent double-contrast arthrograms or results of surgery. All tears were identified in both the sagittal and coronal planes. Because of its ability to demonstrate small meniscal lesions and ligamentous injuries readily, MR imaging with a surface coilmore » may eventually replace the more invasive arthrography.« less

  8. Can T1 w/T2 w ratio be used as a myelin-specific measure in subcortical structures? Comparisons between FSE-based T1 w/T2 w ratios, GRASE-based T1 w/T2 w ratios and multi-echo GRASE-based myelin water fractions.

    PubMed

    Uddin, Md Nasir; Figley, Teresa D; Marrie, Ruth Ann; Figley, Chase R

    2018-03-01

    Given the growing popularity of T 1 -weighted/T 2 -weighted (T 1 w/T 2 w) ratio measurements, the objective of the current study was to evaluate the concordance between T 1 w/T 2 w ratios obtained using conventional fast spin echo (FSE) versus combined gradient and spin echo (GRASE) sequences for T 2 w image acquisition, and to compare the resulting T 1 w/T 2 w ratios with histologically validated myelin water fraction (MWF) measurements in several subcortical brain structures. In order to compare these measurements across a relatively wide range of myelin concentrations, whole-brain T 1 w magnetization prepared rapid acquisition gradient echo (MPRAGE), T 2 w FSE and three-dimensional multi-echo GRASE data were acquired from 10 participants with multiple sclerosis at 3 T. Then, after high-dimensional, non-linear warping, region of interest (ROI) analyses were performed to compare T 1 w/T 2 w ratios and MWF estimates (across participants and brain regions) in 11 bilateral white matter (WM) and four bilateral subcortical grey matter (SGM) structures extracted from the JHU_MNI_SS 'Eve' atlas. Although the GRASE sequence systematically underestimated T 1 w/T 2 w values compared to the FSE sequence (revealed by Bland-Altman and mountain plots), linear regressions across participants and ROIs revealed consistently high correlations between the two methods (r 2 = 0.62 for all ROIs, r 2 = 0.62 for WM structures and r 2 = 0.73 for SGM structures). However, correlations between either FSE-based or GRASE-based T 1 w/T 2 w ratios and MWFs were extremely low in WM structures (FSE-based, r 2 = 0.000020; GRASE-based, r 2 = 0.0014), low across all ROIs (FSE-based, r 2 = 0.053; GRASE-based, r 2 = 0.029) and moderate in SGM structures (FSE-based, r 2 = 0.20; GRASE-based, r 2 = 0.17). Overall, our findings indicated a high degree of correlation (but not equivalence) between FSE-based and GRASE-based T 1 w/T 2 w ratios, and low correlations between T 1 w/T 2 w ratios and MWFs. This

  9. Diffusion-weighted MR imaging findings of kidneys in patients with early phase of obstruction.

    PubMed

    Bozgeyik, Zulkif; Kocakoc, Ercan; Sonmezgoz, Fitnet

    2009-04-01

    Diffusion-weighted (DW) magnetic resonance (MR) imaging is an MR technique used to show molecular diffusion. The apparent diffusion coefficient (ADC), as a quantitative parameter calculated from the DW MR images. The purpose of this study is to evaluate the ability of DW MR imaging in early phase of obstruction due to urolithiasis. Twenty-six patients with acute dilatation of the pelvicalyceal system detected by intravenous urography were included in this study. MR imaging was performed using a 1.5 T whole-body superconducting MR scanner. DW imaging can be performed using single-shot spin-echo, echo-planar imaging (EPI) sequences with the following diffusion gradient b values: 100, 600, 1000 s/mm(2). Circular region of interest (ROI) was placed in the renal parenchyma for the measurement of ADC values in the normal and obstructed kidney. For statistical analyses, Paired t test were used. In spite of obstructed kidneys had the lower ADC values compared to normal kidneys, these alterations were statistically insignificant. We did not observe significantly different ADC values of early phase of obstructed kidneys compared to normal kidneys.

  10. Quantification of red myotomal muscle volume and geometry in the shortfin mako shark (Isurus oxyrinchus) and the salmon shark (Lamna ditropis) using T1-weighted magnetic resonance imaging.

    PubMed

    Perry, Cameron N; Cartamil, Daniel P; Bernal, Diego; Sepulveda, Chugey A; Theilmann, Rebecca J; Graham, Jeffrey B; Frank, Lawrence R

    2007-04-01

    T1-weighted magnetic resonance imaging (MRI) in conjunction with image and segmentation analysis (i.e., the process of digitally partitioning tissues based on specified MR image characteristics) was evaluated as a noninvasive alternative for differentiating muscle fiber types and quantifying the amounts of slow, red aerobic muscle in the shortfin mako shark (Isurus oxyrinchus) and the salmon shark (Lamna ditropis). MRI-determinations of red muscle quantity and position made for the mid-body sections of three mako sharks (73.5-110 cm fork length, FL) are in close agreement (within the 95% confidence intervals) with data obtained for the same sections by the conventional dissection method involving serial cross-sectioning and volumetric analyses, and with previously reported findings for this species. The overall distribution of salmon shark red muscle as a function of body fork length was also found to be consistent with previously acquired serial dissection data for this species; however, MR imaging revealed an anterior shift in peak red muscle cross-sectional area corresponding to an increase in body mass. Moreover, MRI facilitated visualization of the intact and anatomically correct relationship of tendon linking the red muscle and the caudal peduncle. This study thus demonstrates that MRI is effective in acquiring high-resolution three-dimensional digital data with high contrast between different fish tissue types. Relative to serial dissection, MRI allows more precise quantification of the position, volume, and other details about the types of muscle within the fish myotome, while conserving specimen structural integrity. Copyright (c) 2007 Wiley-Liss, Inc.

  11. Prospective and retrospective high order eddy current mitigation for diffusion weighted echo planar imaging.

    PubMed

    Xu, Dan; Maier, Joseph K; King, Kevin F; Collick, Bruce D; Wu, Gaohong; Peters, Robert D; Hinks, R Scott

    2013-11-01

    The proposed method is aimed at reducing eddy current (EC) induced distortion in diffusion weighted echo planar imaging, without the need to perform further image coregistration between diffusion weighted and T2 images. These ECs typically have significant high order spatial components that cannot be compensated by preemphasis. High order ECs are first calibrated at the system level in a protocol independent fashion. The resulting amplitudes and time constants of high order ECs can then be used to calculate imaging protocol specific corrections. A combined prospective and retrospective approach is proposed to apply correction during data acquisition and image reconstruction. Various phantom, brain, body, and whole body diffusion weighted images with and without the proposed method are acquired. Significantly reduced image distortion and misregistration are consistently seen in images with the proposed method compared with images without. The proposed method is a powerful (e.g., effective at 48 cm field of view and 30 cm slice coverage) and flexible (e.g., compatible with other image enhancements and arbitrary scan plane) technique to correct high order ECs induced distortion and misregistration for various diffusion weighted echo planar imaging applications, without the need for further image post processing, protocol dependent prescan, or sacrifice in signal-to-noise ratio. Copyright © 2013 Wiley Periodicals, Inc.

  12. Endometrial cancer: magnetic resonance imaging.

    PubMed

    Manfredi, R; Gui, B; Maresca, G; Fanfani, F; Bonomo, L

    2005-01-01

    Carcinoma of the endometrium is the most common invasive gynecologic malignancy of the female genital tract. Clinically, patients with endometrial carcinoma present with abnormal uterine bleeding. The role of magnetic resonance imaging (MRI) in endometrial carcinoma is disease staging and treatment planning. MRI has been shown to be the most valuable imaging mod-ality in this task, compared with endovaginal ultrasound and computed tomography, because of its intrinsic contrast resolution and multiplanar capability. MRI protocol includes axial T1-weighted images; axial, sagittal, and coronal T2-weighted images; and dynamic gadolinium-enhanced T1-weighted imaging. MR examination is usually performed in the supine position with a phased array multicoil using a four-coil configuration. Endometrial carcinoma is isointense with the normal endometrium and myometrium on noncontrast T1-weighted images and has a variable appearance on T2-weighted images demonstrating heterogeneous signal intensity. The appearance of noninvasive endometrial carcinoma on MRI is characterized by a normal or thickened endometrium, with an intact junctional zone and a sharp tumor-myometrium interface. Invasive endometrial carcinoma is characterized disruption or irregularity of the junctional zone by intermediate signal intensity mass on T2-weighted images. Invasion of the cervical stroma is diagnosed when the low signal intensity cervical stroma is disrupted by the higher signal intensity endometrial carcinoma. MRI in endometrial carcinoma performs better than other imaging modalities in disease staging and treatment planning. Further, the accuracy and the cost of MRI are equivalent to those of surgical staging.

  13. Dynamic characteristics of T2*-weighted signal in calf muscles of peripheral artery disease during low-intensity exercise.

    PubMed

    Li, Zhijun; Muller, Matthew D; Wang, Jianli; Sica, Christopher T; Karunanayaka, Prasanna; Sinoway, Lawrence I; Yang, Qing X

    2017-07-01

    To evaluate the dynamic characteristics of T2* -weighted signal change in exercising skeletal muscle of healthy subjects and peripheral artery disease (PAD) patients under a low-intensity exercise paradigm. Nine PAD patients and nine age- and sex-matched healthy volunteers underwent a low-intensity exercise paradigm while magnetic resonance imaging (MRI) (3.0T) was obtained. T2*-weighted signal time-courses in lateral gastrocnemius, medial gastrocnemius, soleus, and tibialis anterior were acquired and analyzed. Correlations were performed between dynamic T2*-weighted signal and changes in heart rate, mean arterial pressure, leg pain, and perceived exertion. A significant signal decrease was observed during exercise in soleus and tibialis anterior of healthy participants (P = 0.0007-0.04 and 0.001-0.009, respectively). In PAD, negative signals were observed (P = 0.008-0.02 and 0.003-0.01, respectively) in soleus and lateral gastrocnemius during the early exercise stage. Then the signal gradually increased above the baseline in the lateral gastrocnemius during and after exercise in six of the eight patients who completed the study. This signal increase in patients' lateral gastrocnemius was significantly greater than in healthy subjects' during the later exercise stage (two-sample t-tests, P = 0.001-0.03). Heart rate and mean arterial pressure responses to exercise were significantly higher in PAD than healthy subjects (P = 0.036 and 0.008, respectively) and the patients experienced greater leg pain and exertion (P = 0.006 and P = 0.0014, respectively). During low-intensity exercise, there were different dynamic T2*-weighted signal behavior in the healthy and PAD exercising muscles. 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:40-48. © 2016 International Society for Magnetic Resonance in Medicine.

  14. Quantification of Hepatic Steatosis with T1-independent, T2*-corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR Spectroscopy

    PubMed Central

    Hines, Catherine D. G.; Hamilton, Gavin; Sirlin, Claude B.; McKenzie, Charles A.; Yu, Huanzhou; Brittain, Jean H.; Reeder, Scott B.

    2011-01-01

    Purpose: To prospectively compare an investigational version of a complex-based chemical shift–based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. Materials and Methods: This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24–71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2* correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r2), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2* correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Results: Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2* correction, spectral modeling of fat, and magnitude

  15. Susceptibility-weighted imaging of the venous networks around the brain stem.

    PubMed

    Cai, Ming; Zhang, Xiao-Fen; Qiao, Hui-Huang; Lin, Zhong-Xiao; Ren, Chuan-Gen; Li, Jian-Ce; Chen, Cheng-Chun; Zhang, Nu

    2015-02-01

    The venous network of the brainstem is complex and significant. Susceptibility-weighted imaging (SWI) is a practical technique which is sensitive to veins, especially tiny veins. Our purpose of this study was to evaluate the visualization of the venous network of brainstem by using SWI at 3.0 T. The occurrence rate of each superficial veins of brainstem was evaluated by using SWI on a 3 T MR imaging system in 60 volunteers. The diameter of the lateral mesencephalic vein and peduncular vein were measured by SWI using the reconstructed mIP images in the sagittal view. And the outflow of the veins of brainstem were studied and described according to the reconstructed images. The median anterior pontomesencephalic vein, median anterior medullary vein, peduncular vein, right vein of the pontomesencephalic sulcus, and right lateral anterior pontomesencephalic vein were detected in all the subjects (100%). The outer diameter of peduncular vein was 1.38 ± 0.26 mm (range 0.8-1.8 mm). The lateral mesencephalic vein was found in 75% of the subjects and the mean outer diameter was 0.81 ± 0.2 mm (range 0.5-1.2 mm). The inner veins of mesencephalon were found by using SWI. The venous networks around the brain stem can be visualized by SWI clearly. This result can not only provide data for anatomical study, but also may be available for the surgical planning in the infratentorial region.

  16. Spatially weighted mutual information image registration for image guided radiation therapy.

    PubMed

    Park, Samuel B; Rhee, Frank C; Monroe, James I; Sohn, Jason W

    2010-09-01

    To develop a new metric for image registration that incorporates the (sub)pixelwise differential importance along spatial location and to demonstrate its application for image guided radiation therapy (IGRT). It is well known that rigid-body image registration with mutual information is dependent on the size and location of the image subset on which the alignment analysis is based [the designated region of interest (ROI)]. Therefore, careful review and manual adjustments of the resulting registration are frequently necessary. Although there were some investigations of weighted mutual information (WMI), these efforts could not apply the differential importance to a particular spatial location since WMI only applies the weight to the joint histogram space. The authors developed the spatially weighted mutual information (SWMI) metric by incorporating an adaptable weight function with spatial localization into mutual information. SWMI enables the user to apply the selected transform to medically "important" areas such as tumors and critical structures, so SWMI is neither dominated by, nor neglects the neighboring structures. Since SWMI can be utilized with any weight function form, the authors presented two examples of weight functions for IGRT application: A Gaussian-shaped weight function (GW) applied to a user-defined location and a structures-of-interest (SOI) based weight function. An image registration example using a synthesized 2D image is presented to illustrate the efficacy of SWMI. The convergence and feasibility of the registration method as applied to clinical imaging is illustrated by fusing a prostate treatment planning CT with a clinical cone beam CT (CBCT) image set acquired for patient alignment. Forty-one trials are run to test the speed of convergence. The authors also applied SWMI registration using two types of weight functions to two head and neck cases and a prostate case with clinically acquired CBCT/ MVCT image sets. The SWMI registration with

  17. "Black butterfly" sign on T2*-weighted and susceptibility-weighted imaging: A novel finding of chronic venous congestion of the brain stem and spinal cord associated with dural arteriovenous fistulas.

    PubMed

    Enokizono, Mikako; Sato, Noriko; Morikawa, Minoru; Kimura, Yukio; Sugiyama, Atsuhiko; Maekawa, Tomoko; Sone, Daichi; Takewaki, Daiki; Okamoto, Tomoko; Takahashi, Yuji; Horie, Nobutaka; Matsuo, Takayuki

    2017-08-15

    A dural arteriovenous fistula (DAVF) with spinal perimedullary venous drainage can cause progressive myelopathy, and it is sometimes incorrectly diagnosed as another spinal cord disease. Here we report the cases of three individuals with a DAVF (one craniocervical junction DAVF and two tentorial DAVFs) with progressive myelopathy showing unique magnetic resonance (MR) imaging findings. MR T2*WI or susceptibility-weighted imaging (SWI) demonstrated symmetrical dark signal intensity lesions predominantly in the dorsal aspect of medulla and the central gray matter of cervical spinal cord that showed the "black butterfly" silhouette. Cerebral angiography revealed DAVFs draining into anterior and posterior spinal veins. Dark signals on T2*WI and SWI were presumed to be hemorrhages, which were probably caused by prolonged venous congestion. Identifying this "black butterfly" sign can facilitate the diagnosis of DAVF, differentiating DAVF from other spinal cord diseases such as demyelinating lesions and neoplasms. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Development and Evaluation of a Semi-automated Segmentation Tool and a Modified Ellipsoid Formula for Volumetric Analysis of the Kidney in Non-contrast T2-Weighted MR Images.

    PubMed

    Seuss, Hannes; Janka, Rolf; Prümmer, Marcus; Cavallaro, Alexander; Hammon, Rebecca; Theis, Ragnar; Sandmair, Martin; Amann, Kerstin; Bäuerle, Tobias; Uder, Michael; Hammon, Matthias

    2017-04-01

    Volumetric analysis of the kidney parenchyma provides additional information for the detection and monitoring of various renal diseases. Therefore the purposes of the study were to develop and evaluate a semi-automated segmentation tool and a modified ellipsoid formula for volumetric analysis of the kidney in non-contrast T2-weighted magnetic resonance (MR)-images. Three readers performed semi-automated segmentation of the total kidney volume (TKV) in axial, non-contrast-enhanced T2-weighted MR-images of 24 healthy volunteers (48 kidneys) twice. A semi-automated threshold-based segmentation tool was developed to segment the kidney parenchyma. Furthermore, the three readers measured renal dimensions (length, width, depth) and applied different formulas to calculate the TKV. Manual segmentation served as a reference volume. Volumes of the different methods were compared and time required was recorded. There was no significant difference between the semi-automatically and manually segmented TKV (p = 0.31). The difference in mean volumes was 0.3 ml (95% confidence interval (CI), -10.1 to 10.7 ml). Semi-automated segmentation was significantly faster than manual segmentation, with a mean difference = 188 s (220 vs. 408 s); p < 0.05. Volumes did not differ significantly comparing the results of different readers. Calculation of TKV with a modified ellipsoid formula (ellipsoid volume × 0.85) did not differ significantly from the reference volume; however, the mean error was three times higher (difference of mean volumes -0.1 ml; CI -31.1 to 30.9 ml; p = 0.95). Applying the modified ellipsoid formula was the fastest way to get an estimation of the renal volume (41 s). Semi-automated segmentation and volumetric analysis of the kidney in native T2-weighted MR data delivers accurate and reproducible results and was significantly faster than manual segmentation. Applying a modified ellipsoid formula quickly provides an accurate kidney volume.

  19. Weight changes in children in foster care for 1 year.

    PubMed

    Schneiderman, Janet U; Smith, Caitlin; Arnold-Clark, Janet S; Fuentes, Jorge; Duan, Lei

    2013-10-01

    The aims of this study of predominately racial/ethnic minority children in foster care (N=360, birth to 19 years old) in Los Angeles, CA were to examine the (1) prevalence of obesity (≥ 95 percentile) and overweight/obese (≥ 85 percentile) upon entrance to foster care (T1) and after 1 year in foster care (T2); (2) comparison of high weight categories to national statistics; (3) relationship of changes in weight status to age, reason for entry into foster care, and placement. Chi-square test and McNemar test comparing paired proportions were used to determine whether there were significant changes in the proportion of high weight categories between T1 and T2. Chi-square test or Fisher's exact test were used to evaluate the association between age, placement, and reason for foster care with the change in weight category. Changes in weight were categorized as (1) decreased in weight, (2) remained at overweight or obese, (3) increased in weight, or (4) remained normal. The proportion of obese and obese/overweight children between ages 2 and 5 were significantly lower at T2 than T1. There were no significant changes in the prevalence of obesity for the total population at T2. Children age 6 or older had a higher prevalence of obesity and overweight/obesity compared to national statistics. Of children at all ages, 64.7% of children of all ages entered foster care with a normal weight and stayed in the normal range during their first year in foster care, 12.2% decreased their weight, 15.4% remained overweight or obese, and 7.7% increased their weight. Age and parental substance use was related to change in weight category from T1 to T2. Children did not become more overweight or obese in foster care; however 28% of the children were obese or overweight upon entry into foster care. Children who are 6 years or older and obese upon entering foster care should be targeted for weight reduction. The pediatric community and child welfare system need to work together by

  20. Exogenous T3 toxicosis following consumption of a contaminated weight loss supplement.

    PubMed

    D'Arcy, R; McDonnell, M; Spence, K; Courtney, C H

    2017-01-01

    A 42-year-old male presented with a one-week history of palpitations and sweating episodes. The only significant history was of longstanding idiopathic dilated cardiomyopathy. Initial ECG demonstrated a sinus tachycardia. Thyroid function testing, undertaken as part of the diagnostic workup, revealed an un-measureable thyroid-stimulating hormone (TSH) and free thyroxine (T 4 ). Upon questioning the patient reported classical thyrotoxic symptoms over the preceding weeks. Given the persistence of symptoms free tri-iodothyronine (T 3 ) was measured and found to be markedly elevated at 48.9 pmol/L (normal range: 3.1-6.8 pmol/L). No goitre or nodular disease was palpable in the neck. Historically there had never been any amiodarone usage. Radionucleotide thyroid uptake imaging ( 123 I) demonstrated significantly reduced tracer uptake in the thyroid. Upon further questioning the patient reported purchasing a weight loss product online from India which supposedly contained sibutramine. He provided one of the tablets and laboratory analysis confirmed the presence of T 3 in the tablet. Full symptomatic resolution and normalised thyroid function ensued upon discontinuation of the supplement. Free tri-iodothyronine (T 3 ) measurement may be useful in the presence of symptoms suggestive of thyrotoxicosis with discordant thyroid function tests.Thyroid uptake scanning can be a useful aid to differentiating exogenous hormone exposure from endogenous hyperthyroidism.Ingestion of thyroid hormone may be inadvertent in cases of exogenous thyrotoxicosis.Medicines and supplements sourced online for weight loss may contain thyroxine (T 4 ) or T 3 and should be considered as a cause of unexplained exogenous hyperthyroidism.

  1. SU-G-IeP1-09: MRI Evaluation of a Direction-Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer On 3T

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soliman, A; Safigholi, H; Sunnybrook Health Sciences Centre, Toronto, ON

    2016-06-15

    Purpose: To assess image quality and artifact extent of a novel direction modulated brachytherapy (DMBT) tandem applicator on a 3T MRI using various clinical imaging sequences. Methods: The tandem applicator is composed of a tungsten alloy with 6 peripheral grooves covered with a PEEK tip. An MR-compatible phantom with similar dimensions to the female pelvis was manufactured. To visually assess the spatial shift of the applicator’s tip, a mountable radial-fiducial with 4 plastic rods, each of 3mm diameter, was designed to tightly fit on the applicator. The rods are separated by 16 mm and mounted at 90-degree relative to onemore » another. The pelvis phantom was filled with a solution of MnCl2 to mimic T2 relaxation time of the cervix (60-80 ms at 3T).Imaging was performed on a 3T Philips Achieva using a 16-channel Torso coil array. Four MR sequences were tested: T2-weighted fast spin-echo (T2w-FSE), proton density weighted FSE (PDw-FSE), T1-weighted FSE (T1w-FSE) and T1 weighted spoiled gradient echo (T1w-GE). The spatial resolution was kept the same between all sequences: 0.6 × 0.6 × 3 mm{sup 3} with no slice gaps. Para-sagittal images were acquired with the applicator fixed at a 30-degree angle anterior to the B0- field to mimic clinical settings. Results: Minimal artifacts were observed on T2w-FSE, PDw-FSE and T1-FSE, while significant artifacts were seen on T1w-GE images. Artifacts induced in all 3 FSE sequences did not hinder accurate localisation of the tip and the applicator boundaries. The drift of the applicator’s centreline from the radial fiducials was measured and found to be < 1 mm for the 3 FSE sequences. Conclusion: The tungsten–based DMBT applicator can be potentially used on 3T with various clinical sequences without inducing significant artifacts. Further validation on patients as well as the evaluation of relative SNR among the different sequences is required.« less

  2. Ultrahigh-field imaging of the biliary tract at 7 T: initial results of gadoxetic acid-enhanced magnetic resonance cholangiography.

    PubMed

    Fischer, Anja; Kraff, Oliver; Orzada, Stephan; Nensa, Felix; Schäfer, Lena C; Ladd, Mark E; Umutlu, Lale; Lauenstein, Thomas C

    2014-05-01

    The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2-weighted turbo-spin-echo sequence, T1-w volume-interpolated breath-hold examination (VIBE), and fast low-angle shot (FLASH) with inversion recovery (IR) were acquired in coronal orientation. For dynamic imaging, gadoxetic acid was administrated and data were collected for a period of 5 to 40 minutes after injection. The volunteers underwent subsequent T2-w respiratory-gated MRC at 3 T. For qualitative analysis, a 5-point scale was used. Contrast ratios (CRs) were calculated for quantitative assessment. Contrast-enhanced T1-w MRC at 7 T showed a homogeneous depiction of the intrahepatic and extrahepatic biliary tract with a maximum enhancement of 20 minutes after contrast. Volume-interpolated breath-hold examination and FLASH IR provided a good image quality for the intrahepatic (VIBE, 3.60; FLASH IR, 3.67) and extrahepatic bile ducts (VIBE, 3.50; FLASH IR, 3.72). The quantitative analysis revealed high CR values for FLASH IR (intrahepatic CR, 0.41; extrahepatic CR, 0.45) because of an effective suppression of hepatic tissue and vessels. The T2-w TSE at 7 T showed only a poor image quality without diagnostic potential (intrahepatic, 2.22; extrahepatic, 1.93). Seven-tesla VIBE and FLASH revealed superiority in the depiction of the intrahepatic bile ducts, whereas 3-T MRC was superior in the delineation of the extrahepatic biliary tract. Our results demonstrate the feasibility of contrast-enhanced imaging of the biliary ducts at 7 T.

  3. Optimizing T2-weighted magnetic resonance sequences for surface coil microimaging of the eye with regard to lid, eyeball and head moving artifacts.

    PubMed

    Obata, Takayuki; Uemura, Koji; Nonaka, Hiroi; Tamura, Mitsuru; Tanada, Shuji; Ikehira, Hiroo

    2006-01-01

    To acquire high-resolution magnetic resonance (MR) images, we developed a new blinking artifact reduced pulse (BARP) sequence with a surface coil specialized for microscopic imaging (47 mm in diameter). To reduce eye movement, we ascertained that the subjects' eyes were kept open and fixated to the target in the 1.5-T MR gantry. To reduce motion artifacts from blinking, we inserted rest periods for blinking (1.5 s within every 5 s) during MR scanning (T2-weighted fast spin echo; repetition time, 5 s; echo time, 100 ms; echo train, 11; matrix, 256 x 128; field of view, 5 cm; 1-mm thickness x 30 slices). Three scans (100 s x 3) were performed for each normal subject, and they were added together after automatic adjustment for location to reduce quality loss caused by head motion. T2-weighted MR images were acquired with a high resolution and a high signal-to-noise ratio. Motion artifacts were reduced with BARP, as compared with those with random blinking. Intraocular structures such as the iris and ciliary muscles were clearly visualized. Because the whole eye can be covered with a 1-mm thickness by this method, three-dimensional maps can easily be generated from the obtained images. The application of BARP with a surface coil of the human eye might become a useful and widely adopted procedure for MR microimaging.

  4. Free-breathing echo-planar imaging based diffusion-weighted magnetic resonance imaging of the liver with prospective acquisition correction.

    PubMed

    Asbach, Patrick; Hein, Patrick A; Stemmer, Alto; Wagner, Moritz; Huppertz, Alexander; Hamm, Bernd; Taupitz, Matthias; Klessen, Christian

    2008-01-01

    To evaluate soft tissue contrast and image quality of a respiratory-triggered echo-planar imaging based diffusion-weighted sequence (EPI-DWI) with different b values for magnetic resonance imaging (MRI) of the liver. Forty patients were examined. Quantitative and qualitative evaluation of contrast was performed. Severity of artifacts and overall image quality in comparison with a T2w turbo spin-echo (T2-TSE) sequence were scored. The liver-spleen contrast was significantly higher (P < 0.05) for the EPI-DWI compared with the T2-TSE sequence (0.47 +/- 0.11 (b50); 0.48 +/- 0.13 (b300); 0.47 +/- 0.13 (b600) vs 0.38 +/- 0.11). Liver-lesion contrast strongly depends on the b value of the DWI sequence and decreased with higher b values (b50, 0.47 +/- 0.19; b300, 0.40 +/- 0.20; b600, 0.28 +/- 0.23). Severity of artifacts and overall image quality were comparable to the T2-TSE sequence when using a low b value (P > 0.05), artifacts increased and image quality decreased with higher b values (P < 0.05). Respiratory-triggered EPI-DWI of the liver is feasible because good image quality and favorable soft tissue contrast can be achieved.

  5. Applicability of T1-weighted MRI in the assessment of forensic age based on the epiphyseal closure of the humeral head.

    PubMed

    Ekizoglu, Oguzhan; Inci, Ercan; Ors, Suna; Kacmaz, Ismail Eralp; Basa, Can Doruk; Can, Ismail Ozgur; Kranioti, Elena F

    2018-05-26

    This work investigates the value of magnetic resonance imaging analysis of proximal epiphyseal fusion in research examining the growth and development of the humerus and its potential utility in establishing forensic age estimation. In this study, 428 proximal humeral epiphyses (patient age, 12-30 years) were evaluated with T1-weighted turbo spin echo (T1 TSE) sequences in coronal oblique orientation on shoulder MRI images. A scoring system was created following a combination of the Schmeling and Kellinghaus methods. Spearman's rank correlation analysis revealed a significant positive relationship between age and ossification stage of the proximal humeral epiphysis (all subjects: rho = 0.664, p < 0.001; males: 0.631, p < 0.001; females: rho = 0.651, p < 0.001). The intra- and inter-observer reliability assessed using Cohen's kappa statistic was κ = 0.898 and κ = 0.828, respectively. The earliest age of epiphysis closure was 17 years for females and 18 years for males. MRI of the proximal humeral epiphysis can be considered advantageous for forensic age estimation of living individuals in a variety of situations, ranging from monitoring public health to estimating the age of illegal immigrants/asylum seekers, minors engaged in criminal activities, and illegal participants in competitive sports, without the danger of radiation exposure.

  6. T2-weighted prostate MRI at 7 Tesla using a simplified external transmit-receive coil array: correlation with radical prostatectomy findings in two prostate cancer patients.

    PubMed

    Rosenkrantz, Andrew B; Zhang, Bei; Ben-Eliezer, Noam; Le Nobin, Julien; Melamed, Jonathan; Deng, Fang-Ming; Taneja, Samir S; Wiggins, Graham C

    2015-01-01

    To report design of a simplified external transmit-receive coil array for 7 Tesla (T) prostate MRI, including demonstration of the array for tumor localization using T2-weighted imaging (T2WI) at 7T before prostatectomy. Following simulations of transmitter designs not requiring parallel transmission or radiofrequency-shimming, a coil array was constructed using loop elements, with anterior and posterior rows comprising one transmit-receive element and three receive-only elements. This coil structure was optimized using a whole-body phantom. In vivo sequence optimization was performed to optimize achieved flip angle (FA) and signal to noise ratio (SNR) in prostate. The system was evaluated in a healthy volunteer at 3T and 7T. The 7T T2WI was performed in two prostate cancer patients before prostatectomy, and localization of dominant tumors was subjectively compared with histopathological findings. Image quality was compared between 3T and 7T in these patients. Simulations of the B1(+) field in prostate using two-loop design showed good magnitude (B1(+) of 0.245 A/m/w(1/2)) and uniformity (nonuniformity [SD/mean] of 10.4%). In the volunteer, 90° FA was achieved in prostate using 225 v 1 ms hard-pulse (indicating good efficiency), FA maps confirmed good uniformity (14.1% nonuniformity), and SNR maps showed SNR gain of 2.1 at 7T versus 3T. In patients, 7T T2WI showed excellent visual correspondence with prostatectomy findings. 7T images demonstrated higher estimated SNR (eSNR) in benign peripheral zone (PZ) and tumor compared with 3T, but lower eSNR in fat and slight decreases in tumor-to-PZ contrast and PZ-homogeneity. We have demonstrated feasibility of a simplified external coil array for high-resolution T2-weighted prostate MRI at 7T. © 2013 Wiley Periodicals, Inc.

  7. Everyman's prostate phantom: kiwi-fruit substitute for human prostates at magnetic resonance imaging, diffusion-weighted imaging and magnetic resonance spectroscopy.

    PubMed

    Mueller-Lisse, Ullrich G; Murer, Sophie; Mueller-Lisse, Ulrike L; Kuhn, Marissa; Scheidler, Juergen; Scherr, Michael

    2017-08-01

    To apply an easy-to-assemble phantom substitute for human prostates in T2-weighted magnetic resonance imaging (T2WI), diffusion-weighted imaging (DWI) and 3D magnetic resonance spectroscopy (MRS). Kiwi fruit were fixed with gel hot and cold compress packs on two plastic nursery pots, separated by a plastic plate, and submerged in tap water inside a 1-L open-spout plastic watering can for T2WI (TR/TE 7500/101 ms), DWI (5500/61 ms, ADC b50-800 s/mm 2 map) and MRS (940/145 ms) at 3.0 T, with phased array surface coils. One green kiwi fruit was additionally examined with an endorectal coil. Retrospective comparison with benign peripheral zone (PZ) and transitional zone (TZ) of prostate (n = 5), Gleason 6-7a prostate cancer (n = 8) and Gleason 7b-9 prostate cancer (n = 7) validated the phantom. Mean contrast between central placenta (CP) and outer pericarp (OP, 0.346-0.349) or peripheral placenta (PP, 0.364-0.393) of kiwi fruit was similar to Gleason 7b-9 prostate cancer and PZ (0.308) in T2WI. ADC values of OP and PP (1.27 ± 0.07-1.37 ± 0.08 mm 2 /s × 10 -3 ) resembled PZ and TZ (1.39 ± 0.17-1.60 ± 0.24 mm 2 /s × 10 -3 ), while CP (0.91 ± 0.14-0.99 ± 0.10 mm 2 /s × 10 -3 ) resembled Gleason 7b-9 prostate cancer (1.00 ± 0.25 mm 2 /s × 10 -3 ). MR spectra showed peaks of citrate and myo-inositol in kiwi fruit, and citrate and "choline+creatine" in prostates. The phantom worked with an endorectal coil, too. The kiwi fruit phantom reproducibly showed zones similar to PZ, TZ and cancer in human prostates in T2WI and DWI and two metabolite peaks in MRS and appears suitable to compare different MR protocols, coil systems and scanners. • Kiwi fruit appear suitable as phantoms for human prostate in MR examinations. • Kiwi fruit show zonal anatomy like human prostates in T2-weighted MRI and DWI. • MR spectroscopy reliably shows peaks in kiwi fruit (citrate/inositol) and human prostates (citrate

  8. MRI image plane nonuniformity in evaluation of ferrous sulphate dosimeter gel (FeGel) by means of T1-relaxation time.

    PubMed

    Magnusson, P; Bäck, S A; Olsson, L E

    1999-11-01

    MR image nonuniformity can vary significantly with the spin-echo pulse sequence repetition time. When MR images with different nonuniformity shapes are used in a T1-calculation the resulting T1-image becomes nonuniform. As shown in this work the uniformity TR-dependence of the spin-echo pulse sequence is a critical property for T1 measurements in general and for ferrous sulfate dosimeter gel (FeGel) applications in particular. The purpose was to study the characteristics of the MR image plane nonuniformity in FeGel evaluation. This included studies of the possibility of decreasing nonuniformities by selecting uniformity optimized repetition times, studies of the transmitted and received RF-fields and studies of the effectiveness of the correction methods background subtraction and quotient correction. A pronounced MR image nonuniformity variation with repetition and T1 relaxation time was observed, and was found to originate from nonuniform RF-transmission in combination with the inherent differences in T1 relaxation for different repetition times. The T1 calculation itself, the uniformity optimized repetition times, nor none of the correction methods studied could sufficiently correct the nonuniformities observed in the T1 images. The nonuniformities were found to vary considerably less with inversion time for the inversion-recovery pulse sequence, than with repetition time for the spin-echo pulse sequence, resulting in considerably lower T1 image nonuniformity levels.

  9. Comparison of T2, T1rho, and diffusion metrics in assessment of liver fibrosis in rats.

    PubMed

    Zhang, Hui; Yang, Qihua; Yu, Taihui; Chen, Xiaodong; Huang, Jingwen; Tan, Cui; Liang, Biling; Guo, Hua

    2017-03-01

    To evaluate the value of T 2 , T 1 rho, and diffusion metrics in assessment of liver fibrosis in rats. Liver fibrosis in a rat model (n = 72) was induced by injection of carbon tetrachloride (CCl 4 ) at 3T. T 2 , T 1 rho, and diffusion parameters (apparent diffusion coefficient (ADC), D true ) via spin echo (SE) diffusion-weighted imaging (DWI) and stimulated echo acquisition mode (STEAM) DWI with three diffusion times (DT: 80, 106, 186 msec) were obtained in surviving rats with hepatic fibrosis (n = 52) and controls (n = 8). Liver fibrosis stage (F0-F6) was identified based on pathological results using the traditional liver fibrosis staging method for rodents. Nonparametric statistical methods and receiver operating characteristic (ROC) curve analysis were employed to determine the diagnostic accuracy. Mean T 2 , T 1 rho, ADC, and D true with DT = 186 msec correlated with the severity of fibrosis with r = 0.73, 0.83, -0.83, and -0.85 (all P < 0.001), respectively. The average areas under the ROC curve at different stages for T 1 rho and diffusion parameters (DT = 186 msec) were larger than those of T 2 and SE DWI (0.92, 0.92, and 0.92 vs. 0.86, 0.82, and 0.83). The corresponding average sensitivity and specificity for T 1 rho and diffusion parameters with a long DT were larger (89.35 and 88.90, 88.36 and 89.97, 90.16 and 87.13) than T 2 and SE DWI (90.28 and 79.93, 85.30 and 77.64, 78.21 and 82.41). The performances of T 1 rho and D true (DT = 186 msec) were comparable (average AUC: 0.92 and 0.92). Among the evaluated sequences, T 1 rho and STEAM DWI with a long DT may serve as superior imaging biomarkers for assessing liver fibrosis and monitoring disease severity. 1 J. Magn. Reson. Imaging 2017;45:741-750. © 2016 International Society for Magnetic Resonance in Medicine.

  10. Fast CSF MRI for brain segmentation; Cross-validation by comparison with 3D T1-based brain segmentation methods.

    PubMed

    van der Kleij, Lisa A; de Bresser, Jeroen; Hendrikse, Jeroen; Siero, Jeroen C W; Petersen, Esben T; De Vis, Jill B

    2018-01-01

    In previous work we have developed a fast sequence that focusses on cerebrospinal fluid (CSF) based on the long T2 of CSF. By processing the data obtained with this CSF MRI sequence, brain parenchymal volume (BPV) and intracranial volume (ICV) can be automatically obtained. The aim of this study was to assess the precision of the BPV and ICV measurements of the CSF MRI sequence and to validate the CSF MRI sequence by comparison with 3D T1-based brain segmentation methods. Ten healthy volunteers (2 females; median age 28 years) were scanned (3T MRI) twice with repositioning in between. The scan protocol consisted of a low resolution (LR) CSF sequence (0:57min), a high resolution (HR) CSF sequence (3:21min) and a 3D T1-weighted sequence (6:47min). Data of the HR 3D-T1-weighted images were downsampled to obtain LR T1-weighted images (reconstructed imaging time: 1:59 min). Data of the CSF MRI sequences was automatically segmented using in-house software. The 3D T1-weighted images were segmented using FSL (5.0), SPM12 and FreeSurfer (5.3.0). The mean absolute differences for BPV and ICV between the first and second scan for CSF LR (BPV/ICV: 12±9/7±4cc) and CSF HR (5±5/4±2cc) were comparable to FSL HR (9±11/19±23cc), FSL LR (7±4, 6±5cc), FreeSurfer HR (5±3/14±8cc), FreeSurfer LR (9±8, 12±10cc), and SPM HR (5±3/4±7cc), and SPM LR (5±4, 5±3cc). The correlation between the measured volumes of the CSF sequences and that measured by FSL, FreeSurfer and SPM HR and LR was very good (all Pearson's correlation coefficients >0.83, R2 .67-.97). The results from the downsampled data and the high-resolution data were similar. Both CSF MRI sequences have a precision comparable to, and a very good correlation with established 3D T1-based automated segmentations methods for the segmentation of BPV and ICV. However, the short imaging time of the fast CSF MRI sequence is superior to the 3D T1 sequence on which segmentation with established methods is performed.

  11. Dual-mode T1 and T2 magnetic resonance imaging contrast agent based on ultrasmall mixed gadolinium-dysprosium oxide nanoparticles: synthesis, characterization, and in vivo application

    NASA Astrophysics Data System (ADS)

    Tegafaw, Tirusew; Xu, Wenlong; Wasi Ahmad, Md; Baeck, Jong Su; Chang, Yongmin; Bae, Ji Eun; Chae, Kwon Seok; Kim, Tae Jeong; Lee, Gang Ho

    2015-09-01

    A new type of dual-mode T1 and T2 magnetic resonance imaging (MRI) contrast agent based on mixed lanthanide oxide nanoparticles was synthesized. Gd3+ (8S7/2) plays an important role in T1 MRI contrast agents because of its large electron spin magnetic moment resulting from its seven unpaired 4f-electrons, and Dy3+ (6H15/2) has the potential to be used in T2 MRI contrast agents because of its very large total electron magnetic moment: among lanthanide oxide nanoparticles, Dy2O3 nanoparticles have the largest magnetic moments at room temperature. Using these properties of Gd3+ and Dy3+ and their oxide nanoparticles, ultrasmall mixed gadolinium-dysprosium oxide (GDO) nanoparticles were synthesized and their potential to act as a dual-mode T1 and T2 MRI contrast agent was investigated in vitro and in vivo. The D-glucuronic acid coated GDO nanoparticles (davg = 1.0 nm) showed large r1 and r2 values (r2/r1 ≈ 6.6) and as a result clear dose-dependent contrast enhancements in R1 and R2 map images. Finally, the dual-mode imaging capability of the nanoparticles was confirmed by obtaining in vivo T1 and T2 MR images.

  12. Glioma infiltration sign on high b-value diffusion-weighted imaging in gliomas and its prognostic value.

    PubMed

    Zeng, Qiang; Ling, Chenhan; Shi, Feina; Dong, Fei; Jiang, Biao; Zhang, Jianmin

    2018-03-01

    Glioma cells may infiltrate beyond the tumor margins revealed on conventional structural images. To investigate whether the presence of a glioma infiltration sign on high b-value diffusion-weighted imaging (DWI) can predict the prognosis of gliomas. Retrospective cohort. Fifty-two patients with gliomas (14 WHO grade II; 13 WHO grade III; 25 WHO grade IV). 3.0T, including a T 1 -weighted contrast-enhanced (T 1 w-CE) sequence, contrast-enhanced T 2 -flair sequence, and a DWI sequence. T 1 w-CE images and contrast-enhanced T 2 -flair images were used for identifying the tumor region for enhancing and nonenhancing gliomas, respectively. The glioma infiltration sign was defined as the presence of a peritumoral abnormal high signal region on DWI map, which was adjacent to the tumor region and had higher signal than surrounding areas. This sign was assessed on a high b-value DWI map with b = 3000 s/mm 2 . For patients with glioma infiltration sign, DWI3000 max , DWI1000 max , ADC3000 min , and ADC1000 min were measured by drawing a region of interest over the peritumoral abnormal high signal region. Survival analysis was conducted by using Cox regression. Glioma infiltration sign was observed in 28 (53.8%) patients. The occurrence rate of this sign was 92.0% in grade IV gliomas, 30.8% in grade III gliomas, and 7.1% in grade II gliomas. The glioma infiltration sign could independently predict both the progression-free survival (hazard ratio [HR], 95% confidence interval [CI] = 8.58 [3.19-23.03], P < 0.001) and overall survival (HR, 95% CI = 11.90 [3.41-41.55], P < 0.001) after adjustment. For patients with glioma infiltration sign, DWI3000 max (P = 0.005) and ADC3000 min (P = 0.008) were both independent predictors of overall survival after adjustment, while DWI1000 max and ADC1000 min were not. The glioma infiltration sign on high b-value DWI is an independent predictor of poor prognosis in glioma patients. High b-value DWI might be a

  13. Diffusion-weighted imaging in patients with acute brain ischemia at 3 T: current possibilities and future perspectives comparing conventional echoplanar diffusion-weighted imaging and fast spin echo diffusion-weighted imaging sequences using BLADE (PROPELLER).

    PubMed

    Fries, Peter; Runge, Val M; Kirchin, Miles A; Stemmer, Alto; Naul, L Gill; Wiliams, Kenneth D; Reith, Wolfgang; Bücker, Arno; Schneider, Günther

    2009-06-01

    To compare diffusion-weighted imaging (DWI) based on a fast spin echo (FSE) sequence using BLADE (PROPELLER) with conventional DWI-echoplanar imaging (EPI) techniques at 3 T and to demonstrate the influence of hardware developments on signal-to-noise ratio (SNR) with these techniques using 12- and 32-channel head coils. Fourteen patients with brain ischemia were evaluated with DWI using EPI and FSE BLADE sequences, with a 12-channel head coil, in the axial plane and 1 additional plane (either sagittal or coronal). SNR and CNR were calculated from region-of-interest measurements. Scans were evaluated in a blinded fashion by 2 experienced neuroradiologists. SNR of both DWI techniques was evaluated in 12 healthy volunteers using different parallel imaging (PI) factors (for the EPI sequence) and both the 12- and 32-channel coils. DWI-BLADE sequences acquired with the 12-channel coil revealed a significant reduction in SNR (mean +/- SD) of ischemic lesions (SNR(lesion) [5.0 +/- 2.5]), normal brain (SNR(brain) [3.0 +/- 1.9]), and subsequently in CNR (3.0 +/- 1.8) as compared with the DWI-EPI sequence (SNR(lesion) [9.3 +/- 5.2], SNR(brain) [7.7 +/- 3.5], CNR [6.1 +/- 2.8], P < 0.001). Despite this reduction in SNR and CNR, the blinded read revealed a marked preference for the DWI-BLADE sequence, or equality between the sequences, in the majority of patients because lesion detection was degraded by susceptibility artifacts on axial DWI-EPI scans in 14% to 43% of cases (but in no instance with the DWI-BLADE sequence). In particular, preference for the DWI-BLADE sequence or equality between the 2 techniques for lesion detection in the brainstem and cerebellum was observed. On some DWI-BLADE scans, in the additional plane, radial-like artifacts degraded lesion detection.In volunteers, SNR was significantly improved using the 32-channel coil, irrespective of scan technique. Comparing DWI-EPI acquired with the 12-channel coil (iPAT = 2) to DWI-BLADE acquired with the 32-channel

  14. The role of magnetic resonance diffusion-weighted imaging and three-dimensional arterial spin labelling perfusion imaging in the differentiation of parasellar meningioma and cavernous haemangioma.

    PubMed

    Xiao, Hua-Feng; Lou, Xin; Liu, Meng-Yu; Wang, Yu-Lin; Wang, Yan; Chen, Zhi-Ye; Shi, Kai-Ning; Ma, Lin

    2014-08-01

    To evaluate the diagnostic value of magnetic resonance diffusion-weighted imaging (DWI) and three-dimensional arterial spin labelling perfusion imaging (3D-ASL) in distinguishing cavernous haemangioma from parasellar meningioma, using histological data as a reference standard. Patients with parasellar meningioma or parasellar cavernous haemangioma underwent conventional T1- and T2-weighted magnetic resonance imaging (MRI) followed by DWI and 3D-ASL using a 3.0 Tesla MRI. The minimum apparent diffusion coefficient (minADC) from DWI and the maximal normalized cerebral blood flow (nCBF) from 3D-ASL were measured in each tumour. Diagnosis was confirmed by histology. MinADC was significantly lower and nCBF significantly higher in meningioma (n = 19) than cavernous haemangioma (n = 15). There was a significant negative correlation between minADC and nCBF (r = -0.605). DWI and 3D-ASL are useful in differentiating cavernous haemangiomas from parasellar meningiomas, particularly in situations when the appearance on conventional MRI sequences is otherwise ambiguous. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Extended T2-IVIM model for correction of TE dependence of pseudo-diffusion volume fraction in clinical diffusion-weighted magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Jerome, N. P.; d'Arcy, J. A.; Feiweier, T.; Koh, D.-M.; Leach, M. O.; Collins, D. J.; Orton, M. R.

    2016-12-01

    The bi-exponential intravoxel-incoherent-motion (IVIM) model for diffusion-weighted MRI (DWI) fails to account for differential T 2 s in the model compartments, resulting in overestimation of pseudodiffusion fraction f. An extended model, T2-IVIM, allows removal of the confounding echo-time (TE) dependence of f, and provides direct compartment T 2 estimates. Two consented healthy volunteer cohorts (n  =  5, 6) underwent DWI comprising multiple TE/b-value combinations (Protocol 1: TE  =  62-102 ms, b  =  0-250 mm-2s, 30 combinations. Protocol 2: 8 b-values 0-800 mm-2s at TE  =  62 ms, with 3 additional b-values 0-50 mm-2s at TE  =  80, 100 ms scanned twice). Data from liver ROIs were fitted with IVIM at individual TEs, and with the T2-IVIM model using all data. Repeat-measures coefficients of variation were assessed for Protocol 2. Conventional IVIM modelling at individual TEs (Protocol 1) demonstrated apparent f increasing with longer TE: 22.4  ±  7% (TE  =  62 ms) to 30.7  ±  11% (TE  =  102 ms) T2-IVIM model fitting accounted for all data variation. Fitting of Protocol 2 data using T2-IVIM yielded reduced f estimates (IVIM: 27.9  ±  6%, T2-IVIM: 18.3  ±  7%), as well as T 2  =  42.1  ±  7 ms, 77.6  ±  30 ms for true and pseudodiffusion compartments, respectively. A reduced Protocol 2 dataset yielded comparable results in a clinical time frame (11 min). The confounding dependence of IVIM f on TE can be accounted for using additional b/TE images and the extended T2-IVIM model.

  16. MR imaging with i.v. superparamagnetic iron oxide: efficacy in the detection of focal hepatic lesions.

    PubMed

    Winter, T C; Freeny, P C; Nghiem, H V; Mack, L A; Patten, R M; Thomas, C R; Elliott, S

    1993-12-01

    The purpose of this study was to evaluate the efficacy of superparmagnetic iron oxide (SPIO) in the detection of focal hepatic lesions on MR images. The study included 21 patients with 115 focal hepatic lesions and eight patients without focal hepatic lesions. T1- and T2-weighted MR images were obtained at 1.5 T before and 60 min after the end of injection of an SPIO agent. Contrast-enhanced CT scans were obtained in all patients within 10 days after MR imaging. The effect of SPIO on the signal intensity of the liver and spleen was assessed by using quantitative analysis of the region of interest. Efficacy was evaluated by using multiple criteria and unenhanced and SPIO-enhanced images. Evaluations included subjective assessment of image quality, counting the number of lesions detected, and statistical analysis of quantitative changes in the signal intensity of lesions and of normal liver. By all criteria, SPIO-enhanced T2-weighted MR images were superior to unenhanced T2-weighted images and to contrast-enhanced CT scans. Conversely, by all criteria, SPIO-enhanced T1-weighted MR images were worse than unenhanced T1-weighted images and contrast-enhanced CT scans. The mean lesion-to-liver contrast on T2-weighted images was 317% on unenhanced images and 1745% on SPIO-enhanced images. For T1-weighted, the mean contrast was 26% on unenhanced images and 18% on SPIO-enhanced images. SPIO is an efficacious contrast agent for the detection of focal hepatic lesions when T2-weighted MR images are used.

  17. 1T Pixel Using Floating-Body MOSFET for CMOS Image Sensors.

    PubMed

    Lu, Guo-Neng; Tournier, Arnaud; Roy, François; Deschamps, Benoît

    2009-01-01

    We present a single-transistor pixel for CMOS image sensors (CIS). It is a floating-body MOSFET structure, which is used as photo-sensing device and source-follower transistor, and can be controlled to store and evacuate charges. Our investigation into this 1T pixel structure includes modeling to obtain analytical description of conversion gain. Model validation has been done by comparing theoretical predictions and experimental results. On the other hand, the 1T pixel structure has been implemented in different configurations, including rectangular-gate and ring-gate designs, and variations of oxidation parameters for the fabrication process. The pixel characteristics are presented and discussed.

  18. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results.

    PubMed

    Nketiah, Gabriel; Elschot, Mattijs; Kim, Eugene; Teruel, Jose R; Scheenen, Tom W; Bathen, Tone F; Selnæs, Kirsten M

    2017-07-01

    To evaluate the diagnostic relevance of T2-weighted (T2W) MRI-derived textural features relative to quantitative physiological parameters derived from diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in Gleason score (GS) 3+4 and 4+3 prostate cancers. 3T multiparametric-MRI was performed on 23 prostate cancer patients prior to prostatectomy. Textural features [angular second moment (ASM), contrast, correlation, entropy], apparent diffusion coefficient (ADC), and DCE pharmacokinetic parameters (K trans and V e ) were calculated from index tumours delineated on the T2W, DW, and DCE images, respectively. The association between the textural features and prostatectomy GS and the MRI-derived parameters, and the utility of the parameters in differentiating between GS 3+4 and 4+3 prostate cancers were assessed statistically. ASM and entropy correlated significantly (p < 0.05) with both GS and median ADC. Contrast correlated moderately with median ADC. The textural features correlated insignificantly with K trans and V e . GS 4+3 cancers had significantly lower ASM and higher entropy than 3+4 cancers, but insignificant differences in median ADC, K trans , and V e . The combined texture-MRI parameters yielded higher classification accuracy (91%) than the individual parameter sets. T2W MRI-derived textural features could serve as potential diagnostic markers, sensitive to the pathological differences in prostate cancers. • T2W MRI-derived textural features correlate significantly with Gleason score and ADC. • T2W MRI-derived textural features differentiate Gleason score 3+4 from 4+3 cancers. • T2W image textural features could augment tumour characterization.

  19. 7T T₂*-weighted magnetic resonance imaging reveals cortical phase differences between early- and late-onset Alzheimer's disease.

    PubMed

    van Rooden, Sanneke; Doan, Nhat Trung; Versluis, Maarten J; Goos, Jeroen D C; Webb, Andrew G; Oleksik, Ania M; van der Flier, Wiesje M; Scheltens, Philip; Barkhof, Frederik; Weverling-Rynsburger, Annelies W E; Blauw, Gerard Jan; Reiber, Johan H C; van Buchem, Mark A; Milles, Julien; van der Grond, Jeroen

    2015-01-01

    The aim of this study is to explore regional iron-related differences in the cerebral cortex, indicative of Alzheimer's disease pathology, between early- and late-onset Alzheimer's disease (EOAD, LOAD, respectively) patients using 7T magnetic resonance phase images. High-resolution T2(∗)-weighted scans were acquired in 12 EOAD patients and 17 LOAD patients with mild to moderate disease and 27 healthy elderly control subjects. Lobar peak-to-peak phase shifts and regional mean phase contrasts were computed. An increased peak-to-peak phase shift was found for all lobar regions in EOAD patients compared with LOAD patients (p < 0.05). Regional mean phase contrast in EOAD patients was higher than in LOAD patients in the superior medial and middle frontal gyrus, anterior and middle cingulate gyrus, postcentral gyrus, superior and inferior parietal gyrus, and precuneus (p ≤ 0.042). These data suggest that EOAD patients have an increased iron accumulation, possibly related to an increased amyloid deposition, in specific cortical regions as compared with LOAD patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Diagnostic performance and reproducibility of T2w based and diffusion weighted imaging (DWI) based PI-RADSv2 lexicon descriptors for prostate MRI.

    PubMed

    Benndorf, Matthias; Hahn, Felix; Krönig, Malte; Jilg, Cordula Annette; Krauss, Tobias; Langer, Mathias; Dovi-Akué, Philippe

    2017-08-01

    To examine the diagnostic performance of PI-RADSv2 T2w and diffusion weighted imaging (DWI) based lexicon descriptors, inter-observer agreement for descriptor assignment and diagnostic accuracy of the PI-RADSv2 assessment categories for multiparametric prostate MRI. 176 lesions in 79 consecutive patients are analyzed, lesions are histopathologically verified by MRI-ultrasound fusion biopsy. All lesions are rated according to the PI-RADSv2 lexicon, descriptors for T2w and DWI sequences and resulting assessment categories are assigned by two independent blinded radiologists. We perform receiver-operating-characteristic analysis using the assessment categories. To analyze inter-observer agreement, we calculate weighted kappa values for assessment category assignment and unweighted kappa values for descriptor assignment. PI-RADSv2 assessment categories yield an area under the curve of 0.76/0.74 (radiologist 1/radiologist 2), P >0.05. Weighted kappa for agreement is 0.601 in the peripheral zone and 0.580 in the transition zone. We detect a difference in the cancer rate for PI-RADSv2 category 3 between peripheral zone (32%) and transition zone (12%), P <0.05. We obtain moderate agreement at most for descriptor assignment with kappa values ranging from 0.082 (T2w shape in the transition zone) to 0.407 (T2w signal intensity in the peripheral zone) and 0.493 (ADC pattern in the peripheral zone). Our analysis corroborates typical descriptors for benign/malignant lesions, but also reveals insights into potential pitfalls - T2w wedge shaped lesions in the peripheral zone have a considerable cancer rate, despite being labelled category 2 in the lexicon. Agreement for descriptor assignment in the PI-RADSv2 lexicon is at most moderate in our study. Typical descriptors for benign and malignant lesions are validated, whereas the discriminatory power of some descriptors is challenged. The difference in the cancer rate for PI-RADSv2 category 3 between peripheral zone and transition

  1. [Contrastive analysis of artifacts produced by metal dental crowns in 3.0 T magnetic resonance imaging with six sequences].

    PubMed

    Lan, Gao; Yunmin, Lian; Pu, Wang; Haili, Huai

    2016-06-01

    This study aimed to observe and evaluate six 3.0 T sequences of metallic artifacts produced by metal dental crowns. Dental crowns fabricated with four different materials (Co-Gr, Ni-Gr, Ti alloy and pure Ti) were evaluated. A mature crossbreed dog was used as the experimental animal, and crowns were fabricated for its upper right second premolar. Each crown was examined through head MRI (3.0 T) with six sequences, namely, T₁ weighted-imaging of spin echo (T₁W/SE), T₂ weighted-imaging of inversion recovery (T₂W/IR), T₂ star gradient echo (T₂*/GRE), T2 weighted-imaging of fast spin echo (T₂W/FSE), T₁ weighted-imaging of fluid attenuate inversion recovery (T₂W/FLAIR), and T₂ weighted-imaging of propeller (T₂W/PROP). The largest area and layers of artifacts were assessed and compared. The artifact in the T₂*/GRE sequence was significantly wider than those in the other sequences (P < 0.01), whose artifact extent was not significantly different (P > 0.05). T₂*/GRE exhibit the strongest influence on the artifact, whereas the five other sequences contribute equally to artifact generation.

  2. Preclinical Magnetic Resonance Fingerprinting (MRF) at 7 T: Effective Quantitative Imaging for Rodent Disease Models

    PubMed Central

    Gao, Ying; Chen, Yong; Ma, Dan; Jiang, Yun; Herrmann, Kelsey A.; Vincent, Jason A.; Dell, Katherine M.; Drumm, Mitchell L.; Brady-Kalnay, Susann M.; Griswold, Mark A.; Flask, Chris A.; Lu, Lan

    2015-01-01

    High field, preclinical magnetic resonance imaging (MRI) scanners are now commonly used to quantitatively assess disease status and efficacy of novel therapies in a wide variety of rodent models. Unfortunately, conventional MRI methods are highly susceptible to respiratory and cardiac motion artifacts resulting in potentially inaccurate and misleading data. We have developed an initial preclinical, 7.0 T MRI implementation of the highly novel Magnetic Resonance Fingerprinting (MRF) methodology that has been previously described for clinical imaging applications. The MRF technology combines a priori variation in the MRI acquisition parameters with dictionary-based matching of acquired signal evolution profiles to simultaneously generate quantitative maps of T1 and T2 relaxation times and proton density. This preclinical MRF acquisition was constructed from a Fast Imaging with Steady-state Free Precession (FISP) MRI pulse sequence to acquire 600 MRF images with both evolving T1 and T2 weighting in approximately 30 minutes. This initial high field preclinical MRF investigation demonstrated reproducible and differentiated estimates of in vitro phantoms with different relaxation times. In vivo preclinical MRF results in mouse kidneys and brain tumor models demonstrated an inherent resistance to respiratory motion artifacts as well as sensitivity to known pathology. These results suggest that MRF methodology may offer the opportunity for quantification of numerous MRI parameters for a wide variety of preclinical imaging applications. PMID:25639694

  3. Preclinical MR fingerprinting (MRF) at 7 T: effective quantitative imaging for rodent disease models.

    PubMed

    Gao, Ying; Chen, Yong; Ma, Dan; Jiang, Yun; Herrmann, Kelsey A; Vincent, Jason A; Dell, Katherine M; Drumm, Mitchell L; Brady-Kalnay, Susann M; Griswold, Mark A; Flask, Chris A; Lu, Lan

    2015-03-01

    High-field preclinical MRI scanners are now commonly used to quantitatively assess disease status and the efficacy of novel therapies in a wide variety of rodent models. Unfortunately, conventional MRI methods are highly susceptible to respiratory and cardiac motion artifacts resulting in potentially inaccurate and misleading data. We have developed an initial preclinical 7.0-T MRI implementation of the highly novel MR fingerprinting (MRF) methodology which has been described previously for clinical imaging applications. The MRF technology combines a priori variation in the MRI acquisition parameters with dictionary-based matching of acquired signal evolution profiles to simultaneously generate quantitative maps of T1 and T2 relaxation times and proton density. This preclinical MRF acquisition was constructed from a fast imaging with steady-state free precession (FISP) MRI pulse sequence to acquire 600 MRF images with both evolving T1 and T2 weighting in approximately 30 min. This initial high-field preclinical MRF investigation demonstrated reproducible and differentiated estimates of in vitro phantoms with different relaxation times. In vivo preclinical MRF results in mouse kidneys and brain tumor models demonstrated an inherent resistance to respiratory motion artifacts as well as sensitivity to known pathology. These results suggest that MRF methodology may offer the opportunity for the quantification of numerous MRI parameters for a wide variety of preclinical imaging applications. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Automated brain tumor segmentation using spatial accuracy-weighted hidden Markov Random Field.

    PubMed

    Nie, Jingxin; Xue, Zhong; Liu, Tianming; Young, Geoffrey S; Setayesh, Kian; Guo, Lei; Wong, Stephen T C

    2009-09-01

    A variety of algorithms have been proposed for brain tumor segmentation from multi-channel sequences, however, most of them require isotropic or pseudo-isotropic resolution of the MR images. Although co-registration and interpolation of low-resolution sequences, such as T2-weighted images, onto the space of the high-resolution image, such as T1-weighted image, can be performed prior to the segmentation, the results are usually limited by partial volume effects due to interpolation of low-resolution images. To improve the quality of tumor segmentation in clinical applications where low-resolution sequences are commonly used together with high-resolution images, we propose the algorithm based on Spatial accuracy-weighted Hidden Markov random field and Expectation maximization (SHE) approach for both automated tumor and enhanced-tumor segmentation. SHE incorporates the spatial interpolation accuracy of low-resolution images into the optimization procedure of the Hidden Markov Random Field (HMRF) to segment tumor using multi-channel MR images with different resolutions, e.g., high-resolution T1-weighted and low-resolution T2-weighted images. In experiments, we evaluated this algorithm using a set of simulated multi-channel brain MR images with known ground-truth tissue segmentation and also applied it to a dataset of MR images obtained during clinical trials of brain tumor chemotherapy. The results show that more accurate tumor segmentation results can be obtained by comparing with conventional multi-channel segmentation algorithms.

  5. Comparison of [{sup 11}C]choline Positron Emission Tomography With T2- and Diffusion-Weighted Magnetic Resonance Imaging for Delineating Malignant Intraprostatic Lesions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Joe H.; University of Melbourne, Victoria; Lim Joon, Daryl

    2015-06-01

    Purpose: The purpose of this study was to compare the accuracy of [{sup 11}C]choline positron emission tomography (CHOL-PET) with that of the combination of T2-weighted and diffusion-weighted (T2W/DW) magnetic resonance imaging (MRI) for delineating malignant intraprostatic lesions (IPLs) for guiding focal therapies and to investigate factors predicting the accuracy of CHOL-PET. Methods and Materials: This study included 21 patients who underwent CHOL-PET and T2W/DW MRI prior to radical prostatectomy. Two observers manually delineated IPL contours for each scan, and automatic IPL contours were generated on CHOL-PET based on varying proportions of the maximum standardized uptake value (SUV). IPLs identified onmore » prostatectomy specimens defined reference standard contours. The imaging-based contours were compared with the reference standard contours using Dice similarity coefficient (DSC), and sensitivity and specificity values. Factors that could potentially predict the DSC of the best contouring method were analyzed using linear models. Results: The best automatic contouring method, 60% of the maximum SUV (SUV{sub 60}) , had similar correlations (DSC: 0.59) with the manual PET contours (DSC: 0.52, P=.127) and significantly better correlations than the manual MRI contours (DSC: 0.37, P<.001). The sensitivity and specificity values were 72% and 71% for SUV{sub 60}; 53% and 86% for PET manual contouring; and 28% and 92% for MRI manual contouring. The tumor volume and transition zone pattern could independently predict the accuracy of CHOL-PET. Conclusions: CHOL-PET is superior to the combination of T2W/DW MRI for delineating IPLs. The accuracy of CHOL-PET is insufficient for gland-sparing focal therapies but may be accurate enough for focal boost therapies. The transition zone pattern is a new classification that may predict how well CHOL-PET delineates IPLs.« less

  6. Distinguishing liver haemangiomas from metastatic tumours using gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced diffusion-weighted imaging at 1.5T MRI.

    PubMed

    Saito, Kazuhiro; Yoshimura, Nobutaka; Shirota, Natsuhiko; Saguchi, Toru; Sugimoto, Katsutoshi; Tokuuye, Koichi

    2016-10-01

    The aim of this study to evaluate the effectiveness of enhanced diffusion-weighted imaging (DWI) for distinguishing liver haemangiomas from metastatic tumours (mets). This study included 23 patients with 27 haemangiomas and 26 patients with 46 mets. Breath-holding diffusion-weighted imaging (DWI) (b-values of 0, 50, 100, 150, 200, 400 and 800 s/mm 2 ) were obtained before and 20 min after injection of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA). Lesion contrast-to-noise ratios (CNRs) were calculated. The data were processed using the bi-exponential model of intravoxel incoherent motion (IVIM). Receiver operating characteristic analysis was performed to compare the diagnostic performance when distinguishing haemangioma from mets. The CNRs of haemangioma and mets at post-contrast enhancement increased. All IVIM parameters for liver haemangioma and mets showed no significant differences between pre- and post-contrast enhancement. The highest A z value of CNR and IVIM parameters occurred at a post-contrast b-value of 0 s/mm 2 and true diffusion (D). The highest qualitative evaluation occurred at a b-value of 800 s/mm 2 . The sensitivity and specificity, with a CNR of 100 or higher at a post-contrast b-value of 0 s/mm 2 and considered to be haemangioma, were 89% and 67% (<10 mm, 91%, 77%) respectively. The sensitivity and specificity, when D was higher than 1.4 × 10 -3 mm 2 /s, were 74% and 83% (<10 mm, 64%, 77%) respectively. The sensitivity and specificity of qualitative evaluation by enhanced DWI were 74% and 76% (<10 mm, 64%, 80%) respectively. The accuracy of the CNR was highest with b = 0; however, examination at high b-values had advantages in the qualitative evaluation of some small-size lesions. © 2016 The Royal Australian and New Zealand College of Radiologists.

  7. [Value of 3T magnetic resonance dynamic contrast-enhanced and diffusion-weighted imaging in differential diagnosis of musculoskeletal tumors].

    PubMed

    Qi, Zi-hua; Li, Chuan-fu; Ma, Xiang-xing; Yang, Hui; Jiang, Bao-dong; Zhang, Kai; Yu, De-xin

    2012-04-01

    To evaluate the value of magnetic resonance dynamic contrast-enhanced (MR-DCE) and magnetic resonance diffusion-weighted imaging (MR-DWI) in the differentiation of benign and malignant musculoskeletal tumors. Sixty-three patients with pathologically confirmed musculoskeletal tumors were examined with MR-DCE and MR-DWI. Using single shot spin echo planar imaging sequence and different b values of 400, 600, 800 and 1000 s/mm(2), we obtained the apparent diffusion coefficient (ADC) of the lesions. ADC values were measured before and after MR-DCE, with a b value of 600 s/mm(2). The 3D fast acquired multiple phase enhanced fast spoiled gradient recalled echo sequence was obtained for multi-slice of the entire lesion. The time-signal intensity curve (TIC), dynamic contrast-enhanced parameters, maximum slope of increase (MSI), positive enhancement integral, signal enhancement ratio, and time to peak (T(peak)) were also recorded. ADC showed no significant difference between benign and malignant tumors when the b value was 400, 600, 800, or 1000 s/mm(2), and it was not significantly different between benign and malignant tumors in both pre-MR-DCE and post-MR-DCE with b value of 600 s/mm(2). TIC were classified into four types type1 showed rapid progression and gradual drainage; type2 showed rapid progression but had no or slight progression; type 3 showed gradual progression; and type 4 had no or slight progression. Most lesions of type1 or type2 were malignant, whereas most lesions of type 3 or type 4 were benign. When using type1 and type 2 as the standards of malignancy, the diagnostic sensitivity and specificity was 87.23% and 50.00%, respectively. The types of TIC showed significant difference between benign and malignant musculoskeletal tumors(χ(2)=17.009,P=0.001). When using MSI 366.62 ± 174.84 as the standard of malignancy, the diagnostic sensitivity and specificity was 86.78% and 78.67%, respectively. When using T(peak)≤70s as the standard of malignancy, the

  8. Effect of gadolinium injection on diffusion-weighted imaging with background body signal suppression (DWIBS) imaging of breast lesions.

    PubMed

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2014-12-01

    Diffusion-weighted imaging with background body signal suppression (DWIBS) provides both qualitative and quantitative imaging of breast lesions and are usually performed before contrast material injection (CMI). This study aims to assess whether the administration of gadolinium significantly affects DWIBS imaging. 200 patients were prospectively evaluated by MRI with STIR, TSE-T2, pre-CMI DWIBS, contrast enhanced THRIVE-T1 and post-CMI DWIBS sequences. Pre and post-CMI DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤1.44×10(-3) mm(2)/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated for both sequences and represented by ROC analysis. Pre and post-CMI ADC values were compared by using the paired t test. In 150/200 (59%) patients, pre and post-CMI DWIBS indicated the presence of breast lesions, 53 (35%) with ADC values of >1.44×10(-3) mm(2)/s and 97 (65%) with ADC≤1.44×10(-3) mm(2)/s. Pre-CMI and post-DWIBS sequences obtained the same sensitivity, specificity, DA, PPV and NPV values of 97%, 83%, 89%, 79% and 98%. The mean ADC value of benign lesions was 1.831±0.18×10(-3) mm(2)/s before and 1.828±0.18×10(-3) mm(2)/s after CMI. The mean ADC value of the malignant lesions was 1.146±0.16×10(-3) mm(2)/s before and 1.144±0.16×10(-3) mm(2)/s after CMI. No significant difference was found between pre and post CMI ADC values (p>0.05). DWIBS imaging is not influenced by CMI. Breast MR protocol could be modified by placing DWIBS after dynamic contrast enhanced sequences in order to maximize patient cooperation. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Utility of unenhanced fat-suppressed T1-weighted MRI in children with sickle cell disease -- can it differentiate bone infarcts from acute osteomyelitis?

    PubMed

    Delgado, Jorge; Bedoya, Maria A; Green, Abby M; Jaramillo, Diego; Ho-Fung, Victor

    2015-12-01

    Children with sickle cell disease (SCD) are at risk of bone infarcts and acute osteomyelitis. The clinical differentiation between a bone infarct and acute osteomyelitis is a diagnostic challenge. Unenhanced T1-W fat-saturated MR images have been proposed as a potential tool to differentiate bone infarcts from osteomyelitis. To evaluate the reliability of unenhanced T1-W fat-saturated MRI for differentiation between bone infarcts and acute osteomyelitis in children with SCD. We retrospectively reviewed the records of 31 children (20 boys, 11 girls; mean age 10.6 years, range 1.1-17.9 years) with SCD and acute bone pain who underwent MR imaging including unenhanced T1-W fat-saturated images from 2005 to 2010. Complete clinical charts were reviewed by a pediatric hematologist with training in infectious diseases to determine a clinical standard to define the presence or absence of osteomyelitis. A pediatric radiologist reviewed all MR imaging and was blinded to clinical information. Based on the signal intensity in T1-W fat-saturated images, the children were further classified as positive for osteomyelitis (low bone marrow signal intensity) or positive for bone infarct (high bone marrow signal intensity). Based on the clinical standard, 5 children were classified as positive for osteomyelitis and 26 children as positive for bone infarct (negative for osteomyelitis). The bone marrow signal intensity on T1-W fat-saturated imaging was not significant for the differentiation between bone infarct and osteomyelitis (P = 0.56). None of the additional evaluated imaging parameters on unenhanced MRI proved reliable in differentiating these diagnoses. The bone marrow signal intensity on unenhanced T1-W fat-saturated MR images is not a reliable criterion to differentiate bone infarcts from osteomyelitis in children.

  10. Evaluation of image quality of a 32-channel versus a 12-channel head coil at 1.5T for MR imaging of the brain.

    PubMed

    Parikh, P T; Sandhu, G S; Blackham, K A; Coffey, M D; Hsu, D; Liu, K; Jesberger, J; Griswold, M; Sunshine, J L

    2011-02-01

    Multichannel phased-array head coils are undergoing exponential escalation of coil element numbers. While previous technical studies have found gains in SNR and spatial resolution with the addition of element coils, it remains to be determined how these gains affect clinical reading. The purpose of this clinical study was to determine if the SNR and spatial resolution characteristics of a 32-channel head coil result in improvements in perceived image quality and lesion evaluation. Twenty-one patients underwent MR imaging of the brain at 1.5T sequentially with both a 12-channel and a 32-channel receive-only phased-array head coil. Axial T2WIs, T1WIs, FLAIR images, and DWIs were acquired. Anonymized images were compared side-by-side and by sequence for image quality, lesion evaluation, and artifacts by 3 neuroradiologists. Results of the comparison were analyzed for the preference for a specific head coil. FLAIR and DWI images acquired with the 32-channel coil showed significant improvement in image quality in several parameters. T2WIs also improved significantly with acquisition by the 32-channel coil, while T1WIs improved in a limited number of parameters. While lesion evaluation also improved with acquisition of images by the 32-channel coil, there was no apparent improvement in diagnostic quality. There was no difference in artifacts between the 2 coils. Improvements in SNR and spatial resolution attributed to image acquisition with a 32-channel head coil are paralleled by perceived improvements in image quality.

  11. Fast ℓ1-SPIRiT Compressed Sensing Parallel Imaging MRI: Scalable Parallel Implementation and Clinically Feasible Runtime

    PubMed Central

    Murphy, Mark; Alley, Marcus; Demmel, James; Keutzer, Kurt; Vasanawala, Shreyas; Lustig, Michael

    2012-01-01

    We present ℓ1-SPIRiT, a simple algorithm for auto calibrating parallel imaging (acPI) and compressed sensing (CS) that permits an efficient implementation with clinically-feasible runtimes. We propose a CS objective function that minimizes cross-channel joint sparsity in the Wavelet domain. Our reconstruction minimizes this objective via iterative soft-thresholding, and integrates naturally with iterative Self-Consistent Parallel Imaging (SPIRiT). Like many iterative MRI reconstructions, ℓ1-SPIRiT’s image quality comes at a high computational cost. Excessively long runtimes are a barrier to the clinical use of any reconstruction approach, and thus we discuss our approach to efficiently parallelizing ℓ1-SPIRiT and to achieving clinically-feasible runtimes. We present parallelizations of ℓ1-SPIRiT for both multi-GPU systems and multi-core CPUs, and discuss the software optimization and parallelization decisions made in our implementation. The performance of these alternatives depends on the processor architecture, the size of the image matrix, and the number of parallel imaging channels. Fundamentally, achieving fast runtime requires the correct trade-off between cache usage and parallelization overheads. We demonstrate image quality via a case from our clinical experimentation, using a custom 3DFT Spoiled Gradient Echo (SPGR) sequence with up to 8× acceleration via poisson-disc undersampling in the two phase-encoded directions. PMID:22345529

  12. Contrast-enhanced dynamic and diffusion-weighted magnetic resonance imaging at 3.0 T to assess early-stage nasopharyngeal carcinoma.

    PubMed

    Ni, Liangping; Liu, Ying

    2018-04-01

    The present study aimed to assess early-stage nasopharyngeal carcinoma (NPC) with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging (DWI) at 3.0 T. A total of 44 patients newly diagnosed with NPC were included in the present study. All patients underwent MR examination at 3.0 T using DCE-MRI and DWI. The volume transfer constant ( K trans ), flux rate constant between extravascular extracellular space and plasma ( K ep ), the volume of extravascular extracellular space per unit volume of tissue ( V e ) and the apparent diffusion coefficient (ADC) of tumours were investigated. Furthermore, the correlation between clinical stages and ADC value and K trans were analysed. The diagnostic accuracy of K trans and ADC were estimated using receiver operating characteristic curves. NPC stage correlated positively with K trans and negatively with ADC values. Additionally, tumour K trans negatively correlated with ADC value. The sensitivity and accuracy of combined K trans and ADC in distinguishing between stage II and stage III and stage III and IV were higher than the values of either measurement used separately. The present study suggested that K trans and ADC derived from DCE-MRI and DWI may be useful to detect stage early NPC accurately. K trans and ADC in combination were superior than either alone.

  13. [The Role of Imaging in Central Nervous System Infections].

    PubMed

    Yokota, Hajime; Tazoe, Jun; Yamada, Kei

    2015-07-01

    Many infections invade the central nervous system. Magnetic resonance imaging (MRI) is the main tool that is used to evaluate infectious lesions of the central nervous system. The useful sequences on MRI are dependent on the locations, such as intra-axial, extra-axial, and spinal cord. For intra-axial lesions, besides the fundamental sequences, including T1-weighted images, T2-weighted images, and fluid-attenuated inversion recovery (FLAIR) images, advanced sequences, such as diffusion-weighted imaging, diffusion tensor imaging, susceptibility-weighted imaging, and MR spectroscopy, can be applied. They are occasionally used as determinants for quick and correct diagnosis. For extra-axial lesions, understanding the differences among 2D-conventional T1-weighted images, 2D-fat-saturated T1-weighted images, 3D-Spin echo sequences, and 3D-Gradient echo sequence after the administration of gadolinium is required to avoid wrong interpretations. FLAIR plus gadolinium is a useful tool for revealing abnormal enhancement on the brain surface. For the spinal cord, the sequences are limited. Evaluating the distribution and time course of the spinal cord are essential for correct diagnoses. We summarize the role of imaging in central nervous system infections and show the pitfalls, key points, and latest information in them on clinical practices.

  14. Ultra-low field T1 vs. T1rho at 3T and 7T: study of rotationally immobilized protein gels and animal brain tissues

    NASA Astrophysics Data System (ADS)

    Dong, Hui; Inglis, Ben; Barr, Ian; Clarke, John

    2015-03-01

    Clinical magnetic resonance imaging (MRI) machines operating in static fields of typically 1.5 T or 3 T can capture information on slow molecular dynamics utilizing the so-called T1rho technique. This technique, in which a radiofrequency (RF) spin-lock field is applied with microtesla amplitude, has been used, for example, to determine the onset time of stroke in studies on rats. The long RF pulse, however, may exceed the specific absorption rate (SAR) limit, putting subjects at risk. Ultra-low-field (ULF) MRI, based on Superconducting Quantum Interference Devices (SQUIDs), directly detects proton signals at a static magnetic field of typically 50-250 μT. Using our ULF MRI system with adjustable static field of typically 55 to 240 μT, we systematically measured the T1 and T2 dispersion profiles of rotationally immobilized protein gels (bovine serum albumin), ex vivo pig brains, and ex vivo rat brains with induced stroke. Comparing the ULF results with T1rho dispersion obtained at 3 T and 7 T, we find that the degree of protein immobilization determines the frequency-dependence of both T1 and T1rho. Furthermore, T1rho and ULF T1 show similar results for stroke, suggesting that ULF MRI may be used to image traumatic brain injury with negligible SAR. This research was supported by the Henry H. Wheeler, Jr. Brain Imaging Center and the Donaldson Trust.

  15. MR imaging of hand and wrist with a dedicated 0.1-T low-field imaging system.

    PubMed

    Gries, P; Constantinesco, A; Brunot, B; Facello, A

    1991-01-01

    We describe the first results of a new magnetic resonance imaging (MRI) system specially developed for hand and wrist imaging. The system uses a small resistive water-cooled magnet with a vertical magnetic field of 0.1 T in an air gap of 15 cm. The console is based on a microcomputer with a vector signal processor and an image-processing board. There is actually no Faraday cage. For the whole hand, the in-plane spatial resolution is less than 1 mm in the 128 x 128-pixels format for typical slice thicknesses of 3 to 5 mm. Solenoidal volume coils for fingers were developed, giving, in the same matrix format, an in-plane high spatial resolution of 0.22 mm for a typical slice thickness of 3 mm.

  16. Detection of soft-tissue sarcoma recurrence: added value of functional MR imaging techniques at 3.0 T.

    PubMed

    Del Grande, Filippo; Subhawong, Ty; Weber, Kristy; Aro, Michael; Mugera, Charles; Fayad, Laura M

    2014-05-01

    To determine the added value of functional magnetic resonance (MR) sequences (dynamic contrast material-enhanced [DCE] and quantitative diffusion-weighted [DW] imaging with apparent diffusion coefficient [ADC] mapping) for the detection of recurrent soft-tissue sarcomas following surgical resection. This retrospective study was approved by the institutional review board. The requirement to obtain informed consent was waived. Thirty-seven patients referred for postoperative surveillance after resection of soft-tissue sarcoma (35 with high-grade sarcoma) were studied. Imaging at 3.0 T included conventional (T1-weighted, fluid-sensitive, and contrast-enhanced T1-weighted imaging) and functional (DCE MR imaging, DW imaging with ADC mapping) sequences. Recurrences were confirmed with biopsy or resection. A disease-free state was determined with at least 6 months of follow-up. Two readers independently recorded the signal and morphologic characteristics with conventional sequences, the presence or absence of arterial enhancement at DCE MR imaging, and ADCs of the surgical bed. The accuracy of conventional MR imaging in the detection of recurrence was compared with that with the addition of functional sequences. The Fisher exact and Wilcoxon rank sum tests were used to define the accuracy of imaging features, the Cohen κ and Lin interclass correlation were used to define interobserver variability, and receiver operating characteristic analysis was used to define a threshold to detect recurrence and assess reader confidence after the addition of functional imaging to conventional sequences. There were six histologically proved recurrences in 37 patients. Sensitivity and specificity of MR imaging in the detection of tumor recurrence were 100% (six of six patients) and 52% (16 of 31 patients), respectively, with conventional sequences, 100% (six of six patients) and 97% (30 of 31 patients) with the addition of DCE MR imaging, and 60% (three of five patients) and 97% (30 of

  17. TH-A-18C-10: Dynamic Intensity Weighted Region of Interest Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pearson, E; Pan, X; Pelizzari, C

    2014-06-15

    Purpose: For image guidance tasks full image quality is not required throughout the entire image. With dynamic filtration of the kV imaging beam the noise properties of the CT image can be locally controlled, providing a high quality image around the target volume with a lower quality surrounding region while providing substantial dose sparing to the patient as well as reduced scatter fluence on the detector. Methods: A dynamic collimation device with 3mm copper blades has been designed to mount in place of the bowtie filter on the On-Board Imager (Varian Medical Systems). The beam intensity is reduced by 95%more » behind the copper filters and the aperture is controlled dynamically to conformally illuminate a given ROI during a standard cone-beam CT scan. A data correction framework to account for the physical effects of the collimator prior to reconstruction was developed. Furthermore, to determine the dose savings and scatter reduction a monte carlo model was built in BEAMnrc with specifics from the Varian Monte Carlo Data Package. The MC model was validated with Gafchromic film. Results: The reconstructed image shows image quality comparable to a standard scan in the specified ROI, with higher noise and streaks in the outer region but still sufficient information for alignment to high contrast structures. The monte carlo modeling showed that the scatter-to-primary ratio was reduced from 1.26 for an unfiltered scan to 0.45 for an intensity weighted scan, suggesting that image quality may be improved in the inner ROI. Dose in the inner region was reduced 10–15% due to reduced scatter and by as much as 75% in the outer region. Conclusion: Dynamic intensity-weighted ROI imaging allows reduction of imaging dose to sensitive organs away from the target region while providing images that retain their utility for patient setup and procedure guidance. Funding was provided in part by Varian Medical Systems and NIH Grants 1RO1CA120540, T32EB002103, S10 RR021039 and P

  18. MR imaging of the prostate at 3 Tesla: comparison of an external phased-array coil to imaging with an endorectal coil at 1.5 Tesla.

    PubMed

    Sosna, Jacob; Pedrosa, Ivan; Dewolf, William C; Mahallati, Houman; Lenkinski, Robert E; Rofsky, Neil M

    2004-08-01

    To qualitatively compare the image quality of torso phased-array 3-Tesla (3T) imaging of the prostate with that of endorectal 1.5-Tesla imaging. Twenty cases of torso phased-array prostate imaging performed at 3-Tesla with FSE T2 weighted images were evaluated by two readers independently for visualization of the posterior border (PB), seminal vesicles (SV), neurovascular bundles (NVB), and image quality rating (IQR). Studies were performed at large fields of view(FOV) (25 cm) (14 cases) (3TL) and smaller FOV (14 cm) (19 cases) (3TS). A comparison was made to 20 consecutive cases of 1.5-T endorectal evaluation performed during the same time period.Results. 3TL produced a significantly better image quality compared with the small FOV for PB (P = .0001), SV (P =.0001), and IQR (P = .0001). There was a marginally significant difference within the NVB category (P = .0535). 3TL produced an image of similar quality to image quality at 1.5 T for PB (P = .3893), SV (P = .8680), NB (P = .2684), and IQR (P = .8599). Prostate image quality at 3T with a torso phased-array coil can be comparable with that of endorectal 1.5-T imaging. These findings suggest that additional options are now available for magnetic resonance imaging of the prostate gland.

  19. Fast CSF MRI for brain segmentation; Cross-validation by comparison with 3D T1-based brain segmentation methods

    PubMed Central

    de Bresser, Jeroen; Hendrikse, Jeroen; Siero, Jeroen C. W.; Petersen, Esben T.; De Vis, Jill B.

    2018-01-01

    Objective In previous work we have developed a fast sequence that focusses on cerebrospinal fluid (CSF) based on the long T2 of CSF. By processing the data obtained with this CSF MRI sequence, brain parenchymal volume (BPV) and intracranial volume (ICV) can be automatically obtained. The aim of this study was to assess the precision of the BPV and ICV measurements of the CSF MRI sequence and to validate the CSF MRI sequence by comparison with 3D T1-based brain segmentation methods. Materials and methods Ten healthy volunteers (2 females; median age 28 years) were scanned (3T MRI) twice with repositioning in between. The scan protocol consisted of a low resolution (LR) CSF sequence (0:57min), a high resolution (HR) CSF sequence (3:21min) and a 3D T1-weighted sequence (6:47min). Data of the HR 3D-T1-weighted images were downsampled to obtain LR T1-weighted images (reconstructed imaging time: 1:59 min). Data of the CSF MRI sequences was automatically segmented using in-house software. The 3D T1-weighted images were segmented using FSL (5.0), SPM12 and FreeSurfer (5.3.0). Results The mean absolute differences for BPV and ICV between the first and second scan for CSF LR (BPV/ICV: 12±9/7±4cc) and CSF HR (5±5/4±2cc) were comparable to FSL HR (9±11/19±23cc), FSL LR (7±4, 6±5cc), FreeSurfer HR (5±3/14±8cc), FreeSurfer LR (9±8, 12±10cc), and SPM HR (5±3/4±7cc), and SPM LR (5±4, 5±3cc). The correlation between the measured volumes of the CSF sequences and that measured by FSL, FreeSurfer and SPM HR and LR was very good (all Pearson’s correlation coefficients >0.83, R2 .67–.97). The results from the downsampled data and the high-resolution data were similar. Conclusion Both CSF MRI sequences have a precision comparable to, and a very good correlation with established 3D T1-based automated segmentations methods for the segmentation of BPV and ICV. However, the short imaging time of the fast CSF MRI sequence is superior to the 3D T1 sequence on which

  20. Time-Dependent Changes in T1 during Fracture Healing in Juvenile Rats: A Quantitative MR Approach

    PubMed Central

    Baron, Katharina; Neumayer, Bernhard; Amerstorfer, Eva; Scheurer, Eva; Diwoky, Clemens; Stollberger, Rudolf; Sprenger, Hanna; Weinberg, Annelie M.

    2016-01-01

    Quantitative magnetic resonance imaging (qMRI) offers several advantages in imaging and determination of soft tissue alterations when compared to qualitative imaging techniques. Although applications in brain and muscle tissues are well studied, its suitability to quantify relaxation times of intact and injured bone tissue, especially in children, is widely unknown. The objective observation of a fracture including its age determination can become of legal interest in cases of child abuse or maltreatment. Therefore, the aim of this study is the determination of time dependent changes in intact and corresponding injured bones in immature rats via qMRI, to provide the basis for an objective and radiation-free approach for fracture dating. Thirty-five MR scans of 7 Sprague-Dawley rats (male, 4 weeks old, 100 ± 5 g) were acquired on a 3T MRI scanner (TimTrio, Siemens AG, Erlangen, Germany) after the surgical infliction of an epiphyseal fracture in the tibia. The images were taken at days 1, 3, 7, 14, 28, 42 and 82 post-surgery. A proton density-weighted and a T1-weighted 3D FLASH sequence were acquired to calculate the longitudinal relaxation time T1 of the fractured region and the surrounding tissues. The calculation of T1 in intact and injured bone resulted in a quantitative observation of bone development in intact juvenile tibiae as well as the bone healing process in the injured tibiae. In both areas, T1 decreased over time. To evaluate the differences in T1 behaviour between the intact and injured bone, the relative T1 values (bone-fracture) were calculated, showing clear detectable alterations of T1 after fracture occurrence. These results indicate that qMRI has a high potential not only for clinically relevant applications to detect growth defects or developmental alterations in juvenile bones, but also for forensically relevant applications such as the dating of fractures in cases of child abuse or maltreatment. PMID:27832068

  1. Lightweight, compact, and high-performance 3T MR system for imaging the brain and extremities.

    PubMed

    Foo, Thomas K F; Laskaris, Evangelos; Vermilyea, Mark; Xu, Minfeng; Thompson, Paul; Conte, Gene; Van Epps, Christopher; Immer, Christopher; Lee, Seung-Kyun; Tan, Ek T; Graziani, Dominic; Mathieu, Jean-Baptise; Hardy, Christopher J; Schenck, John F; Fiveland, Eric; Stautner, Wolfgang; Ricci, Justin; Piel, Joseph; Park, Keith; Hua, Yihe; Bai, Ye; Kagan, Alex; Stanley, David; Weavers, Paul T; Gray, Erin; Shu, Yunhong; Frick, Matthew A; Campeau, Norbert G; Trzasko, Joshua; Huston, John; Bernstein, Matt A

    2018-03-13

    To build and evaluate a small-footprint, lightweight, high-performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole-body clinical 3T MRI scanners, while achieving substantial reductions in installation costs. A conduction-cooled magnet was developed that uses less than 12 liters of liquid helium in a gas-charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42-cm inner-diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet-gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80-mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1-MVA gradient drivers. In a comparison of anatomical imaging in 16 patients using T 2 -weighted 3D fluid-attenuated inversion recovery (FLAIR) between the compact 3T and whole-body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80-mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain. The compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole-body MRI. The increased gradient performance has reliably resulted in consistently improved image quality. © 2018 International Society for Magnetic Resonance in Medicine.

  2. Estimation of T2* Relaxation Time of Breast Cancer: Correlation with Clinical, Imaging and Pathological Features

    PubMed Central

    Seo, Mirinae; Jahng, Geon-Ho; Sohn, Yu-Mee; Rhee, Sun Jung; Oh, Jang-Hoon; Won, Kyu-Yeoun

    2017-01-01

    Objective The purpose of this study was to estimate the T2* relaxation time in breast cancer, and to evaluate the association between the T2* value with clinical-imaging-pathological features of breast cancer. Materials and Methods Between January 2011 and July 2013, 107 consecutive women with 107 breast cancers underwent multi-echo T2*-weighted imaging on a 3T clinical magnetic resonance imaging system. The Student's t test and one-way analysis of variance were used to compare the T2* values of cancer for different groups, based on the clinical-imaging-pathological features. In addition, multiple linear regression analysis was performed to find independent predictive factors associated with the T2* values. Results Of the 107 breast cancers, 92 were invasive and 15 were ductal carcinoma in situ (DCIS). The mean T2* value of invasive cancers was significantly longer than that of DCIS (p = 0.029). Signal intensity on T2-weighted imaging (T2WI) and histologic grade of invasive breast cancers showed significant correlation with T2* relaxation time in univariate and multivariate analysis. Breast cancer groups with higher signal intensity on T2WI showed longer T2* relaxation time (p = 0.005). Cancer groups with higher histologic grade showed longer T2* relaxation time (p = 0.017). Conclusion The T2* value is significantly longer in invasive cancer than in DCIS. In invasive cancers, T2* relaxation time is significantly longer in higher histologic grades and high signal intensity on T2WI. Based on these preliminary data, quantitative T2* mapping has the potential to be useful in the characterization of breast cancer. PMID:28096732

  3. In vivo magnetization transfer and diffusion-weighted magnetic resonance imaging detects thrombus composition in a mouse model of deep vein thrombosis.

    PubMed

    Phinikaridou, Alkystis; Andia, Marcelo E; Saha, Prakash; Modarai, Bijan; Smith, Alberto; Botnar, René M

    2013-05-01

    Deep vein thrombosis remains a major health problem necessitating accurate diagnosis. Thrombolysis is associated with significant morbidity and is effective only for the treatment of unorganized thrombus. We tested the feasibility of in vivo magnetization transfer (MT) and diffusion-weighted magnetic resonance imaging to detect thrombus organization in a murine model of deep vein thrombosis. Deep vein thrombosis was induced in the inferior vena cava of male BALB/C mice. Magnetic resonance imaging was performed at days 1, 7, 14, 21, and 28 after thrombus induction using MT, diffusion-weighted, inversion-recovery, and T1-mapping protocols. Delayed enhancement and T1 mapping were repeated 2 hours after injection of a fibrin contrast agent. Finally, excised thrombi were used for histology. We found that MT and diffusion-weighted imaging can detect histological changes associated with thrombus aging. MT rate (MTR) maps and percentage of MT rate (%MTR) allowed visualization and quantification of the thrombus protein content, respectively. The %MTR increased with thrombus organization and was significantly higher at days 14, 21, and 28 after thrombus induction (days 1, 7, 14, 21, 28: %MTR=2483±451, 2079±1210, 7029±2490, 10 295±4356, 32 994±25 449; PANOVA<0.05). There was a significant positive correlation between the %MTR and the histological protein content of the thrombus (r=0.70; P<0.05). The apparent diffusion coefficient was lower in erythrocyte-rich and collagen-rich thrombus (0.72±0.10 and 0.69±0.05 [×10(-3) mm(2)/s]). Thrombus at days 7 and 14 had the highest apparent diffusion coefficient values (0.95±0.09 and 1.10±0.18 [×10(-3) mm(2)/s]). MT and diffusion-weighted magnetic resonance imaging sequences are promising for the staging of thrombus composition and could be useful in guiding medical intervention.

  4. Detection of compression vessels in trigeminal neuralgia by surface-rendering three-dimensional reconstruction of 1.5- and 3.0-T magnetic resonance imaging.

    PubMed

    Shimizu, Masahiro; Imai, Hideaki; Kagoshima, Kaiei; Umezawa, Eriko; Shimizu, Tsuneo; Yoshimoto, Yuhei

    2013-01-01

    Surface-rendered three-dimensional (3D) 1.5-T magnetic resonance (MR) imaging is useful for presurgical simulation of microvascular decompression. This study compared the sensitivity and specificity of 1.5- and 3.0-T surface-rendered 3D MR imaging for preoperative identification of the compression vessels of trigeminal neuralgia. One hundred consecutive patients underwent microvascular decompression for trigeminal neuralgia. Forty and 60 patients were evaluated by 1.5- and 3.0-T MR imaging, respectively. Three-dimensional MR images were constructed on the basis of MR imaging, angiography, and venography data and evaluated to determine the compression vessel before surgery. MR imaging findings were compared with the microsurgical findings to compare the sensitivity and specificity of 1.5- and 3.0-T MR imaging. The agreement between MR imaging and surgical findings depended on the compression vessels. For superior cerebellar artery, 1.5- and 3.0-T MR imaging had 84.4% and 82.7% sensitivity and 100% and 100% specificity, respectively. For anterior inferior cerebellar artery, 1.5- and 3.0-T MR imaging had 33.3% and 50% sensitivity and 92.9% and 95% specificity, respectively. For the petrosal vein, 1.5- and 3.0-T MR imaging had 75% and 64.3% sensitivity and 79.2% and 78.1% specificity, respectively. Complete pain relief was obtained in 36 of 40 and 55 of 60 patients undergoing 1.5- and 3.0-T MR imaging, respectively. The present study showed that both 1.5- and 3.0-T MR imaging provided high sensitivity and specificity for preoperative assessment of the compression vessels of trigeminal neuralgia. Preoperative 3D imaging provided very high quality presurgical simulation, resulting in excellent clinical outcomes. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Diffusion Kurtosis Imaging of Acute Infarction: Comparison with Routine Diffusion and Follow-up MR Imaging.

    PubMed

    Yin, Jianzhong; Sun, Haizhen; Wang, Zhiyun; Ni, Hongyan; Shen, Wen; Sun, Phillip Zhe

    2018-05-01

    Purpose To determine the relationship between diffusion-weighted imaging (DWI) and diffusion kurtosis imaging (DKI) in patients with acute stroke at admission and the tissue outcome 1 month after onset of stroke. Materials and Methods Patients with stroke underwent DWI (b values = 0, 1000 sec/mm 2 along three directions) and DKI (b values = 0, 1000, 2000 sec/mm 2 along 20 directions) within 24 hours after symptom onset and 1 month after symptom onset. For large lesions (diameter ≥ 1 cm), acute lesion volumes at DWI and DKI were compared with those at follow-up T2-weighted imaging by using Spearman correlation analysis. For small lesions (diameter < 1 cm), the number of acute lesions at DWI and DKI and follow-up T2-weighted imaging was counted and compared by using the McNemar test. Results Thirty-seven patients (mean age, 58 years; range, 35-82 years) were included. There were 32 large lesions and 138 small lesions. For large lesions, the volumes of acute lesions on kurtosis maps showed no difference from those on 1-month follow-up T2-weighted images (P = .532), with a higher correlation coefficient than those on the apparent diffusion coefficient and mean diffusivity maps (R 2 = 0.730 vs 0.479 and 0.429). For small lesions, the number of acute lesions on DKI, but not on DWI, images was consistent with that on the follow-up T2-weighted images (P = .125). Conclusion DKI complements DWI for improved prediction of outcome of acute ischemic stroke. © RSNA, 2018.

  6. Differentiating Laryngeal Carcinomas from Precursor Lesions by Diffusion-Weighted Magnetic Resonance Imaging at 3.0 T: A Preliminary Study

    PubMed Central

    Shang, De-Sheng; Ruan, Ling-Xiang; Zhou, Shui-Hong; Bao, Yang-Yang; Cheng, Ke-Jia; Wang, Qin-Ying

    2013-01-01

    Background Diffusion-weighted magnetic resonance imaging (DWI) has been introduced in head and neck cancers. Due to limitations in the performance of laryngeal DWI, including the complex anatomical structure of the larynx leading to susceptibility effects, the value of DWI in differentiating benign from malignant laryngeal lesions has largely been ignored. We assessed whether a threshold for the apparent diffusion coefficient (ADC) was useful in differentiating preoperative laryngeal carcinomas from precursor lesions by turbo spin-echo (TSE) DWI and 3.0-T magnetic resonance. Methods We evaluated DWI and the ADC value in 33 pathologically proven laryngeal carcinomas and 17 precancerous lesions. Results The sensitivity, specificity, and accuracy were 81.8%, 64.7%, 76.0% by laryngostroboscopy, respectively. The sensitivity, specificity, and accuracy of conventional magnetic resonance imaging were 90.9%, 76.5%, 86.0%, respectively. Qualitative DWI analysis produced sensitivity, specificity, and accuracy values of 100.0, 88.2, and 96.0%, respectively. The ADC values were lower for patients with laryngeal carcinoma (mean 1.195±0.32×10−3 mm2/s) versus those with laryngeal precancerous lesions (mean 1.780±0.32×10−3 mm2/s; P<0.001). ROC analysis showed that the area under the curve was 0.956 and the optimum threshold for the ADC was 1.455×10−3 mm2/s, resulting in a sensitivity of 94.1%, a specificity of 90.9%, and an accuracy of 92.9%. Conclusions Despite some limitations, including the small number of laryngeal carcinomas included, DWI may detect changes in tumor size and shape before they are visible by laryngostroboscopy. The ADC values were lower for patients with laryngeal carcinoma than for those with laryngeal precancerous lesions. The proposed cutoff for the ADC may help distinguish laryngeal carcinomas from laryngeal precancerous lesions. PMID:23874693

  7. Combined Fat Imaging/Look Locker for mapping of lipid spin-lattice (T1) relaxation time

    NASA Astrophysics Data System (ADS)

    Jihyun Park, Annie; Yung, Andrew; Kozlowski, Piotr; Reinsberg, Stefan

    2012-10-01

    Tumor hypoxia is a main problem arising in the treatment of cancer due to its resistance to cytotoxic therapy such as radiation and chemotherapy, and selection for more aggressive tumor phenotypes. Attempts to improve and quantify tumor oxygenation are in development and tools to assess the success of such schemes are required. Monitoring oxygen level with MRI using T1 based method (where oxygen acts as T1 shortening agent) is a dynamic and noninvasive way to study tumor characteristics. The method's sensitivity to oxygen is higher in lipids than in water due to higher oxygen solubility in lipid. Our study aims to develop a time-efficient method to spatially map T1 of fat inside the tumor. We are combining two techniques: Fat/Water imaging and Look Locker (a rapid T1 measurement technique). Fat/Water Imaging is done with either Dixon or Direct Phase Encoding (DPE) method. The combination of these techniques poses new challenges that are tackled using spin dynamics simulations as well as experiments in vitro and in vivo.

  8. Magnetic resonance enteroclysis in patients with Crohn's disease: fat saturated T2-weighted sequences for evaluation of inflammatory activity.

    PubMed

    Grieser, Christian; Denecke, Timm; Steffen, Ingo G; Werner, Scarlett; Kröncke, Thomas; Guckelberger, Olaf; Pape, Ulrich-Frank; Meier, Johannes; Thiel, Regina; Kivelitz, Dietmar; Sturm, Andreas; Hamm, Bernd; Röttgen, Rainer

    2012-04-01

    To evaluate fat saturated (fs) T2-weighted (w) fast relaxation fast spin echo (FRFSE)-sequences compared to the standard protocol with contrast agent for the evaluation of inflammatory activity in patients with Crohn's Disease (CD). Fourty-eight patients (male, 17; female, 33; mean age, 37 years) with suspicion of inflammatory activity in proven CD who underwent MR enteroclysis (MRE) at 1.5T (GE Healthcare) were retrospectively included. Two blinded radiologists analyzed MRE images for presence and extent of CD lesions and degree of local inflammation for fsT2-w FRFSE and contrast enhanced T1-w images (T2-activity; T1-activity; score, 1-4) in consensus. Furthermore, mural signal intensity (SI) ratios (T2-ratio; T1-ratio) were recorded. Patient based MRE findings were correlated with endoscopic (45 patients), surgical (6 patients), histopathological, and clinical data (CDAI) as a surrogate reference standard. In total, 24 of 48 eligible patients presented with acute inflammatory activity with 123 affected bowel segments. ROC analysis of the total inflammatory score presented an AUC of 0.93 (p<0.001) for T2-activity (T1-activity, AUC 0.63; p=0.019). ROC analysis revealed an AUC of 0.76 (p<0.001) for the T2-ratio (T1-ratio, AUC 0.51; p=0.93). General linear regression model revealed T2-activity (p=0.001) and age (p=0.024) as predictive factors of acute bowel inflammation. T2-w FRFSE-sequences can depict CD lesions and help to assess the inflammation activity, even with improved accuracy as compared to contrast-enhanced T1-w sequences. Copyright © 2011 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.

  9. Reconstruction of 7T-Like Images From 3T MRI

    PubMed Central

    Bahrami, Khosro; Shi, Feng; Zong, Xiaopeng; Shin, Hae Won; An, Hongyu

    2016-01-01

    In the recent MRI scanning, ultra-high-field (7T) MR imaging provides higher resolution and better tissue contrast compared to routine 3T MRI, which may help in more accurate and early brain diseases diagnosis. However, currently, 7T MRI scanners are more expensive and less available at clinical and research centers. These motivate us to propose a method for the reconstruction of images close to the quality of 7T MRI, called 7T-like images, from 3T MRI, to improve the quality in terms of resolution and contrast. By doing so, the post-processing tasks, such as tissue segmentation, can be done more accurately and brain tissues details can be seen with higher resolution and contrast. To do this, we have acquired a unique dataset which includes paired 3T and 7T images scanned from same subjects, and then propose a hierarchical reconstruction based on group sparsity in a novel multi-level Canonical Correlation Analysis (CCA) space, to improve the quality of 3T MR image to be 7T-like MRI. First, overlapping patches are extracted from the input 3T MR image. Then, by extracting the most similar patches from all the aligned 3T and 7T images in the training set, the paired 3T and 7T dictionaries are constructed for each patch. It is worth noting that, for the training, we use pairs of 3T and 7T MR images from each training subject. Then, we propose multi-level CCA to map the paired 3T and 7T patch sets to a common space to increase their correlations. In such space, each input 3T MRI patch is sparsely represented by the 3T dictionary and then the obtained sparse coefficients are used together with the corresponding 7T dictionary to reconstruct the 7T-like patch. Also, to have the structural consistency between adjacent patches, the group sparsity is employed. This reconstruction is performed with changing patch sizes in a hierarchical framework. Experiments have been done using 13 subjects with both 3T and 7T MR images. The results show that our method outperforms previous

  10. Various ligand-coated ultrasmall gadolinium-oxide nanoparticles: Water proton relaxivity and in-vivo T1 MR image

    NASA Astrophysics Data System (ADS)

    Park, Ja Young; Kim, Sung June; Lee, Gang Ho; Jin, Seonguk; Chang, Yongmin; Bae, Ji Eun; Chae, Kwon Seok

    2015-04-01

    Surface coating of nanoparticles with ligands is essential in magnetic resonance imaging (MRI) because of solubility in water and biocompatibility. In this study, five organic molecules were used for surface coating of ultrasmall gadolinium-oxide (Gd2O3) nanoparticles (d avg = 2.0 nm). All of the samples showed large longitudinal (r1) and transverse (r2) water proton relaxivities with r2/r1 ratios that were close to one, corresponding to ideal conditions for T1 MRI contrast agents. Finally, in-vivo T1 MR images were acquired to prove the effectiveness of the surface-coated ultrasmall Gd2O3 nanoparticles as a T1 MRI contrast agent.

  11. Rectal cancer: assessment of complete response to preoperative combined radiation therapy with chemotherapy--conventional MR volumetry versus diffusion-weighted MR imaging.

    PubMed

    Curvo-Semedo, Luís; Lambregts, Doenja M J; Maas, Monique; Thywissen, Thomas; Mehsen, Rana T; Lammering, Guido; Beets, Geerard L; Caseiro-Alves, Filipe; Beets-Tan, Regina G H

    2011-09-01

    To determine diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging for assessment of complete tumor response (CR) after combined radiation therapy with chemotherapy (CRT) in patients with locally advanced rectal cancer (LARC) by means of volumetric signal intensity measurements and apparent diffusion coefficient (ADC) measurements and to compare the performance of DW imaging with that of T2-weighted MR volumetry. A retrospective analysis of 50 patients with LARC, for whom clinical and imaging data were retrieved from a previous imaging study approved by the local institutional ethical committee and for which all patients provided informed consent, was conducted. Patients underwent pre- and post-CRT standard T2-weighted MR and DW MR. Two independent readers placed free-hand regions of interest (ROIs) in each tumor-containing section on both data sets to determine pre- and post-CRT tumor volumes and tumor volume reduction rates (volume). ROIs were copied to an ADC map to calculate tumor ADCs. Histopathologic findings were the standard of reference. Receiver operating characteristic (ROC) curves were generated to compare performance of T2-weighted and DW MR volumetry and ADC. The intraclass correlation coefficient (ICC) was used to evaluate interobserver variability and the correlation between T2-weighted and DW MR volumetry. Areas under the ROC curve (AUCs) for identification of a CR that was based on pre-CRT volume, post-CRT volume, and volume, respectively, were 0.57, 0.70, and 0.84 for T2-weighted MR versus 0.63, 0.93, and 0.92 for DW MR volumetry (P = .15, .02, .42). Pre- and post-CRT ADC and ADC AUCs were 0.55, 0.54, and 0.51, respectively. Interobserver agreement was excellent for all pre-CRT measurements (ICC, 0.91-0.96) versus good (ICC, 0.61-0.79) for post-CRT measurements. ICC between T2-weighted and DW MR volumetry was excellent (0.97) for pre-CRT measurements versus fair (0.25) for post-CRT measurements. Post-CRT DW MR

  12. Further exploration of MRI techniques for liver T1rho quantification.

    PubMed

    Zhao, Feng; Yuan, Jing; Deng, Min; Lu, Pu-Xuan; Ahuja, Anil T; Wang, Yi-Xiang J

    2013-12-01

    With biliary duct ligation and CCl4 induced rat liver fibrosis models, recent studies showed that MR T1rho imaging is able to detect liver fibrosis, and the degree of fibrosis is correlated with the degree of elevation of the T1rho measurements, suggesting liver T1rho quantification may play an important role for liver fibrosis early detection and grading. It has also been reported it is feasible to obtain consistent liver T1rho measurement for human subjects at 3 Tesla (3 T), and preliminary clinical data suggest liver T1rho is increased in patients with cirrhosis. In these previous studies, T1rho imaging was used with the rotary-echo spin-lock pulse for T1rho preparation, and number of signal averaging (NSA) was 2. Due to the presence of inhomogeneous B0 field, artifacts may occur in the acquired T1rho-weighted images. The method described by Dixon et al. (Magn Reson Med 1996;36:90-4), which is a hard RF pulse with 135° flip angle and same RF phase as the spin-locking RF pulse is inserted right before and after the spin-locking RF pulse, has been proposed to reduce sensitivity to B0 field inhomogeneity in T1rho imaging. In this study, we compared the images scanned by rotary-echo spin-lock pulse method (sequence 1) and the pulse modified according to Dixon method (sequence 2). When the artifacts occurred in T1rho images, we repeated the same scan until satisfactory. We accepted images if artifact in liver was less than 10% of liver area by visual estimation. When NSA =2, the breath-holding duration for data acquisition of one slice scanning was 8 sec due to a delay time of 6,000 ms for magnetization restoration. If NSA =1, the duration was shortened to be 2 sec. In previous studies, manual region of interest (ROI) analysis of T1rho map was used. In this current study, histogram analysis was also applied to evaluate liver T1rho value on T1rho maps. MRI data acquisition was performed on a 3 T clinical scanner. There were 29 subjects with 61 examinations obtained

  13. Weight-adapted iodinated contrast media administration in abdomino-pelvic CT: Can image quality be maintained?

    PubMed

    Perrin, E; Jackson, M; Grant, R; Lloyd, C; Chinaka, F; Goh, V

    2018-02-01

    In many centres, a fixed method of contrast-media administration is used for CT regardless of patient body habitus. The aim of this trial was to assess contrast enhancement of the aorta, portal vein, liver and spleen during abdomino-pelvic CT imaging using a weight-adapted contrast media protocol compared to the current fixed dose method. Thirty-nine oncology patients, who had previously undergone CT abdomino-pelvic imaging at the institution using a fixed contrast media dose, were prospectively imaged using a weight-adapted contrast media dose (1.4 ml/kg). The two sets of images were assessed for contrast enhancement levels (HU) at locations in the liver, aorta, portal vein and spleen during portal-venous enhancement phase. The t-test was used to compare the difference in results using a non-inferiority margin of 10 HU. When the contrast dose was tailored to patient weight, contrast enhancement levels were shown to be non-inferior to the fixed dose method (liver p < 0.001; portal vein p = 0.003; aorta p = 0.001; spleen p = 0.001). As a group, patients received a total contrast dose reduction of 165 ml using the weight-adapted method compared to the fixed dose method, with a mean cost per patient of £6.81 and £7.19 respectively. Using a weight-adapted method of contrast media administration was shown to be non-inferior to a fixed dose method of contrast media administration. Patients weighing 76 kg, or less, received a lower contrast dose which may have associated cost savings. A weight-adapted contrast media protocol should be implemented for portal-venous phase abdomino-pelvic CT for oncology patients with adequate renal function (>70 ml/min/1.73 m 2 ). Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  14. Implementation and assessment of diffusion-weighted partial Fourier readout-segmented echo-planar imaging.

    PubMed

    Frost, Robert; Porter, David A; Miller, Karla L; Jezzard, Peter

    2012-08-01

    Single-shot echo-planar imaging has been used widely in diffusion magnetic resonance imaging due to the difficulties in correcting motion-induced phase corruption in multishot data. Readout-segmented EPI has addressed the multishot problem by introducing a two-dimensional nonlinear navigator correction with online reacquisition of uncorrectable data to enable acquisition of high-resolution diffusion data with reduced susceptibility artifact and T*(2) blurring. The primary shortcoming of readout-segmented EPI in its current form is its long acquisition time (longer than similar resolution single-shot echo-planar imaging protocols by approximately the number of readout segments), which limits the number of diffusion directions. By omitting readout segments at one side of k-space and using partial Fourier reconstruction, readout-segmented EPI imaging times could be reduced. In this study, the effects of homodyne and projection onto convex sets reconstructions on estimates of the fractional anisotropy, mean diffusivity, and diffusion orientation in fiber tracts and raw T(2)- and trace-weighted signal are compared, along with signal-to-noise ratio results. It is found that projections onto convex sets reconstruction with 3/5 segments in a 2 mm isotropic diffusion tensor image acquisition and 9/13 segments in a 0.9 × 0.9 × 4.0 mm(3) diffusion-weighted image acquisition provide good fidelity relative to the full k-space parameters. This allows application of readout-segmented EPI to tractography studies, and clinical stroke and oncology protocols. Copyright © 2011 Wiley-Liss, Inc.

  15. Design and Application of Combined 8-Channel Transmit and 10-Channel Receive Arrays and Radiofrequency Shimming for 7-T Shoulder Magnetic Resonance Imaging

    PubMed Central

    Brown, Ryan; Deniz, Cem Murat; Zhang, Bei; Chang, Gregory; Sodickson, Daniel K.; Wiggins, Graham C.

    2014-01-01

    Objective The objective of the study was to investigate the feasibility of 7-T shoulder magnetic resonance imaging by developing transmit and receive radiofrequency (RF) coil arrays and exploring RF shim methods. Materials and Methods A mechanically flexible 8-channel transmit array and an anatomically conformable 10-channel receive array were designed and implemented. The transmit performance of various RF shim methods was assessed through local flip angle measurements in the right and left shoulders of 6 subjects. The receive performance was assessed through signal-to-noise ratio measurements using the developed 7-T coil and a baseline commercial 3-T coil. Results The 7-T transmit array driven with phase-coherent RF shim weights provided adequate B1+ efficiency and uniformity for turbo spin echo shoulder imaging. B1+ twisting that is characteristic of high-field loop coils necessitates distinct RF shim weights in the right and left shoulders. The 7-T receive array provided a 2-fold signal-to-noise ratio improvement over the 3-T array in the deep articular shoulder cartilage. Conclusions Shoulder imaging at 7-T is feasible with a custom transmit/receive array either in a single-channel transmit mode with a fixed RF shim or in a parallel transmit mode with a subject-specific RF shim. PMID:24056112

  16. Three-dimensional T1 and T2* mapping of human lung parenchyma using interleaved saturation recovery with dual echo ultrashort echo time imaging (ITSR-DUTE).

    PubMed

    Gai, Neville D; Malayeri, Ashkan A; Bluemke, David A

    2017-04-01

    To develop and assess a new technique for three-dimensional (3D) full lung T1 and T2* mapping using a single free breathing scan during a clinically feasible time. A 3D stack of dual-echo ultrashort echo time (UTE) radial acquisition interleaved with and without a WET (water suppression enhanced through T1 effects) saturation pulse was used to map T1 and T2* simultaneously in a single scan. Correction for modulation due to multiple views per segment was derived. Bloch simulations were performed to study saturation pulse excitation profile on lung tissue. Optimization of the saturation delay time (for T1 mapping) and echo time (for T2* mapping) was performed. Monte Carlo simulation was done to predict accuracy and precision of the sequence with signal-to-noise ratio of in vivo images used in the simulation. A phantom study was carried out using the 3D interleaved saturation recovery with dual echo ultrashort echo time imaging (ITSR-DUTE) sequence and reference standard inversion recovery spin echo sequence (IR-SE) to compare accuracy of the sequence. Nine healthy volunteers were imaged and mean (SD) of T1 and T2* in lung parenchyma at 3T were estimated through manually assisted segmentation. 3D lung coverage with a resolution of 2.5 × 2.5 × 6 mm 3 was performed and nominal scan time was recorded for the scans. Repeatability was assessed in three of the volunteers. Regional differences in T1/T2* values were also assessed. The phantom study showed accuracy of T1 values to be within 2.3% of values obtained from IR-SE. Mean T1 value in lung parenchyma was 1002 ± 82 ms while T2* was 0.85 ± 0.1 ms. Scan time was ∼10 min for volunteer scans. Mean coefficient of variation (CV) across slices was 0.057 and 0.09, respectively. Regional variation along the gravitational direction and between right and left lung were not significant (P = 0.25 and P = 0.06, respectively) for T1. T2* showed significant variation (P = 0.03) along the

  17. Comparison and Optimization of 3.0 T Breast Images Quality of Diffusion-Weighted Imaging with Multiple B-Values.

    PubMed

    Han, Xiaowei; Li, Junfeng; Wang, Xiaoyi

    2017-04-01

    Breast 3.0 T magnetic resonance diffusion-weighted imaging (MR-DWI) of benign and malignant lesions were obtained to measure and calculate the signal-to-noise ratio (SNR), signal intensity ratio (SIR), and contrast-to-noise ratio (CNR) of lesions at different b-values. The variation patterns of SNR and SIR were analyzed with different b-values and the images of DWI were compared at four different b-values with higher image quality. The effect of SIR on the differential diagnostic efficiency of benign and malignant lesions was compared using receiver operating characteristic curves to provide a reference for selecting the optimal b-value. A total of 96 qualified patients with 112 lesions and 14 patients with their contralateral 14 normal breasts were included in this study. The single-shot echo planar imaging sequence was used to perform the DWI and a total of 13 b-values were used: 0, 50, 100, 200, 400, 600, 800, 1000, 1200, 1500, 1800, 2000, and 2500 s/mm 2 . On DWI, the suitable regions of interest were selected. The SNRs of normal breasts (SNR normal ), SNR lesions , SIR, and CNR of benign and malignant lesions were measured on DWI with different b-values and calculated. The variation patterns of SNR, SIR, and CNR values on DWI for normal breasts, benign lesions, and malignant lesions with different b-values were analyzed by using Pearson correlation analysis. The SNR and SIR of benign and malignant lesions with the same b-values were compared using t-tests. The diagnostic efficiencies of SIR with different b-values for benign and malignant lesions were evaluated using receiver operating characteristic curves. Breast DWI had higher CNR for b-values ranging from 600 to 1200 s/mm 2 . It had the best CNR at b = 1000 s/mm 2 for the benign lesions and at b = 1200 s/mm 2 for the malignant lesions. The signal intensity and SNR values of normal breasts decreased with increasing b-values, with a negative correlation (r = -0.945, P < 0.01). The

  18. Fully convolutional networks (FCNs)-based segmentation method for colorectal tumors on T2-weighted magnetic resonance images.

    PubMed

    Jian, Junming; Xiong, Fei; Xia, Wei; Zhang, Rui; Gu, Jinhui; Wu, Xiaodong; Meng, Xiaochun; Gao, Xin

    2018-06-01

    Segmentation of colorectal tumors is the basis of preoperative prediction, staging, and therapeutic response evaluation. Due to the blurred boundary between lesions and normal colorectal tissue, it is hard to realize accurate segmentation. Routinely manual or semi-manual segmentation methods are extremely tedious, time-consuming, and highly operator-dependent. In the framework of FCNs, a segmentation method for colorectal tumor was presented. Normalization was applied to reduce the differences among images. Borrowing from transfer learning, VGG-16 was employed to extract features from normalized images. We conducted five side-output blocks from the last convolutional layer of each block of VGG-16 along the network, these side-output blocks can deep dive multiscale features, and produced corresponding predictions. Finally, all of the predictions from side-output blocks were fused to determine the final boundaries of the tumors. A quantitative comparison of 2772 colorectal tumor manual segmentation results from T2-weighted magnetic resonance images shows that the average Dice similarity coefficient, positive predictive value, specificity, sensitivity, Hammoude distance, and Hausdorff distance were 83.56, 82.67, 96.75, 87.85%, 0.2694, and 8.20, respectively. The proposed method is superior to U-net in colorectal tumor segmentation (P < 0.05). There is no difference between cross-entropy loss and Dice-based loss in colorectal tumor segmentation (P > 0.05). The results indicate that the introduction of FCNs contributed to accurate segmentation of colorectal tumors. This method has the potential to replace the present time-consuming and nonreproducible manual segmentation method.

  19. Automatic selection of landmarks in T1-weighted head MRI with regression forests for image registration initialization.

    PubMed

    Wang, Jianing; Liu, Yuan; Noble, Jack H; Dawant, Benoit M

    2017-10-01

    Medical image registration establishes a correspondence between images of biological structures, and it is at the core of many applications. Commonly used deformable image registration methods depend on a good preregistration initialization. We develop a learning-based method to automatically find a set of robust landmarks in three-dimensional MR image volumes of the head. These landmarks are then used to compute a thin plate spline-based initialization transformation. The process involves two steps: (1) identifying a set of landmarks that can be reliably localized in the images and (2) selecting among them the subset that leads to a good initial transformation. To validate our method, we use it to initialize five well-established deformable registration algorithms that are subsequently used to register an atlas to MR images of the head. We compare our proposed initialization method with a standard approach that involves estimating an affine transformation with an intensity-based approach. We show that for all five registration algorithms the final registration results are statistically better when they are initialized with the method that we propose than when a standard approach is used. The technique that we propose is generic and could be used to initialize nonrigid registration algorithms for other applications.

  20. Discrete pre-processing step effects in registration-based pipelines, a preliminary volumetric study on T1-weighted images.

    PubMed

    Muncy, Nathan M; Hedges-Muncy, Ariana M; Kirwan, C Brock

    2017-01-01

    Pre-processing MRI scans prior to performing volumetric analyses is common practice in MRI studies. As pre-processing steps adjust the voxel intensities, the space in which the scan exists, and the amount of data in the scan, it is possible that the steps have an effect on the volumetric output. To date, studies have compared between and not within pipelines, and so the impact of each step is unknown. This study aims to quantify the effects of pre-processing steps on volumetric measures in T1-weighted scans within a single pipeline. It was our hypothesis that pre-processing steps would significantly impact ROI volume estimations. One hundred fifteen participants from the OASIS dataset were used, where each participant contributed three scans. All scans were then pre-processed using a step-wise pipeline. Bilateral hippocampus, putamen, and middle temporal gyrus volume estimations were assessed following each successive step, and all data were processed by the same pipeline 5 times. Repeated-measures analyses tested for a main effects of pipeline step, scan-rescan (for MRI scanner consistency) and repeated pipeline runs (for algorithmic consistency). A main effect of pipeline step was detected, and interestingly an interaction between pipeline step and ROI exists. No effect for either scan-rescan or repeated pipeline run was detected. We then supply a correction for noise in the data resulting from pre-processing.

  1. Discrete pre-processing step effects in registration-based pipelines, a preliminary volumetric study on T1-weighted images

    PubMed Central

    2017-01-01

    Pre-processing MRI scans prior to performing volumetric analyses is common practice in MRI studies. As pre-processing steps adjust the voxel intensities, the space in which the scan exists, and the amount of data in the scan, it is possible that the steps have an effect on the volumetric output. To date, studies have compared between and not within pipelines, and so the impact of each step is unknown. This study aims to quantify the effects of pre-processing steps on volumetric measures in T1-weighted scans within a single pipeline. It was our hypothesis that pre-processing steps would significantly impact ROI volume estimations. One hundred fifteen participants from the OASIS dataset were used, where each participant contributed three scans. All scans were then pre-processed using a step-wise pipeline. Bilateral hippocampus, putamen, and middle temporal gyrus volume estimations were assessed following each successive step, and all data were processed by the same pipeline 5 times. Repeated-measures analyses tested for a main effects of pipeline step, scan-rescan (for MRI scanner consistency) and repeated pipeline runs (for algorithmic consistency). A main effect of pipeline step was detected, and interestingly an interaction between pipeline step and ROI exists. No effect for either scan-rescan or repeated pipeline run was detected. We then supply a correction for noise in the data resulting from pre-processing. PMID:29023597

  2. New-Generation Laser-lithographed Dual-Axis Magnetically Assisted Remote-controlled Endovascular Catheter for Interventional MR Imaging: In Vitro Multiplanar Navigation at 1.5 T and 3 T versus X-ray Fluoroscopy.

    PubMed

    Moftakhar, Parham; Lillaney, Prasheel; Losey, Aaron D; Cooke, Daniel L; Martin, Alastair J; Thorne, Bradford R H; Arenson, Ronald L; Saeed, Maythem; Wilson, Mark W; Hetts, Steven W

    2015-12-01

    To assess the feasibility of multiplanar vascular navigation with a new magnetically assisted remote-controlled (MARC) catheter with real-time magnetic resonance (MR) imaging at 1.5 T and 3 T and to compare it with standard x-ray guidance in simulated endovascular catheterization procedures. A 1.6-mm-diameter custom clinical-grade microcatheter prototype with lithographed double-saddle coils at the distal tip was deflected with real-time MR imaging. Two inexperienced operators and two experienced operators catheterized anteroposterior (celiac, superior mesenteric, and inferior mesenteric arteries) and mediolateral (renal arteries) branch vessels in a cryogel abdominal aortic phantom. This was repeated with conventional x-ray fluoroscopy by using clinical catheters and guidewires. Mean procedure times and percentage success data were analyzed with linear mixed-effects regression. The MARC catheter tip was visible at 1.5 T and 3 T. Among inexperienced operators, MARC MR imaging guidance was not statistically different from x-ray guidance at 1.5 T (67% successful vessel selection turns with MR imaging vs 76% with x-ray guidance, P = .157) and at 3 T (75% successful turns with MR imaging vs 76% with x-ray guidance, P = .869). Experienced operators were more successful in catheterizing vessels with x-ray guidance (98% success within 60 seconds) than with 1.5-T (65%, P < .001) or 3-T (75%) MR imaging. Among inexperienced operators, mean procedure time was nearly equivalent by using MR imaging (31 seconds) and x-ray guidance (34 seconds, P = .436). Among experienced operators, catheterization was faster with x-ray guidance (20 seconds) compared with 1.5-T MR imaging (42 seconds, P < .001), but MARC guidance improved at 3 T (31 seconds). MARC MR imaging guidance at 3 T was not significantly different from x-ray guidance for the celiac (P = .755), superior mesenteric (P = .358), and inferior mesenteric (P = .065) arteries. Multiplanar navigation with a new MARC catheter

  3. New-Generation Laser-lithographed Dual-Axis Magnetically Assisted Remote-controlled Endovascular Catheter for Interventional MR Imaging: In Vitro Multiplanar Navigation at 1.5 T and 3 T versus X-ray Fluoroscopy

    PubMed Central

    Moftakhar, Parham; Lillaney, Prasheel; Losey, Aaron D.; Cooke, Daniel L.; Martin, Alastair J.; Thorne, Bradford R. H.; Arenson, Ronald L.; Saeed, Maythem; Wilson, Mark W.

    2015-01-01

    Purpose To assess the feasibility of multiplanar vascular navigation with a new magnetically assisted remote-controlled (MARC) catheter with real-time magnetic resonance (MR) imaging at 1.5 T and 3 T and to compare it with standard x-ray guidance in simulated endovascular catheterization procedures. Materials and Methods A 1.6-mm–diameter custom clinical-grade microcatheter prototype with lithographed double-saddle coils at the distal tip was deflected with real-time MR imaging. Two inexperienced operators and two experienced operators catheterized anteroposterior (celiac, superior mesenteric, and inferior mesenteric arteries) and mediolateral (renal arteries) branch vessels in a cryogel abdominal aortic phantom. This was repeated with conventional x-ray fluoroscopy by using clinical catheters and guidewires. Mean procedure times and percentage success data were analyzed with linear mixed-effects regression. Results The MARC catheter tip was visible at 1.5 T and 3 T. Among inexperienced operators, MARC MR imaging guidance was not statistically different from x-ray guidance at 1.5 T (67% successful vessel selection turns with MR imaging vs 76% with x-ray guidance, P = .157) and at 3 T (75% successful turns with MR imaging vs 76% with x-ray guidance, P = .869). Experienced operators were more successful in catheterizing vessels with x-ray guidance (98% success within 60 seconds) than with 1.5-T (65%, P < .001) or 3-T (75%) MR imaging. Among inexperienced operators, mean procedure time was nearly equivalent by using MR imaging (31 seconds) and x-ray guidance (34 seconds, P = .436). Among experienced operators, catheterization was faster with x-ray guidance (20 seconds) compared with 1.5-T MR imaging (42 seconds, P < .001), but MARC guidance improved at 3 T (31 seconds). MARC MR imaging guidance at 3 T was not significantly different from x-ray guidance for the celiac (P = .755), superior mesenteric (P = .358), and inferior mesenteric (P = .065) arteries. Conclusion

  4. Vanishing Parotid Tumors on MR Imaging

    PubMed Central

    Matsusue, Eiji; Fujihara, Yoshio; Matsuda, Eiken; Tokuyasu, Yusuke; Nakamoto, Shu; Nakamura, Kazuhiko; Ogawa, Toshihide

    2018-01-01

    Background Of all parotid gland tumors, only oncocytoma has been reported to appear isointense to the parotid gland, namely vanishing, on fat-saturated T2 and T1 postcontrast gadolinium-enhanced magnetic resonance imaging (MRI). The purpose of this study was to evaluate vanishing of parotid tumors on conventional MRI with and/or without postcontrast gadolinium-enhancement and on diffusion weighted imaging (DWI). Methods In 8 of 51 patients, ten parotid gland tumors had homogeneously enhanced lesions and were retrospectively analysed. Comparisons of signal intensity between those parotid tumors and parotid glands and evaluations of vanishing were performed on T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), fat-suppressed T2WI (FS-T2WI), postcontrast gadolinium-enhanced T1WI (CE-T1WI) and fat-suppressed CE-T1WI (FS-CE-T1WI), DWI as well as apparent diffusion coefficient (ADC). Results Ten parotid gland tumors consisted of five Warthin tumors, two pleomorphic adenomas, two parotid carcinomas (small cell carcinoma and adenoid cystic carcinoma) and one oncocytoma. All tumors showed hypointensity on T1WI and hyperintensity on DWI. Nine of ten tumors showed vanishing on the other MR sequences. All Warthin tumors showed vanishing on FS-T2WI, FS-CE-T1WI and the ADC map. One oncocytoma showed vanishing on FS-T2WI and the ADC map and hyperintensity on FS-CE-T1WI. All pleomorphic adenomas showed vanishing on T2WI and CE-T1WI. One adenoid cystic carcinoma showed vanishing only on CE-T1WI. Conclusion Vanishing of parotid tumors can be observed not only on FS-T2WI and FS-CE-T1WI but also on T2WI, CE-T1WI and ADC mapping. PMID:29599620

  5. MR imaging of breast implants.

    PubMed

    Gorczyca, D P

    1994-11-01

    MR imaging has proved to be an excellent imaging modality in locating free silicone and evaluating an implant for rupture, with a sensitivity of approximately 94% and specificity of 97%. Silicone has a unique MR resonance frequency and long T1 and T2 relaxation times, which allows several MR sequences to provide excellent diagnostic images. The most commonly used sequences include T2-weighted, STIR, and chemical shift imaging (Figs. 3, 13, and 14). The T2-weighted and STIR sequences are often used in conjunction with chemical water suppression. The most reliable findings on MR images for detection of implant rupture include identification of the collapsed implant shell (linguine sign) and free silicone within the breast parenchyma.

  6. 3D isotropic T2-weighted fast spin echo (VISTA) versus 2D T2-weighted fast spin echo in evaluation of the calcaneofibular ligament in the oblique coronal plane.

    PubMed

    Park, H J; Lee, S Y; Choi, Y J; Hong, H P; Park, S J; Park, J H; Kim, E

    2017-02-01

    To investigate whether the image quality of three-dimensional (3D) volume isotropic fast spin echo acquisition (VISTA) magnetic resonance imaging (MRI) of the calcaneofibular ligament (CFL) view is comparable to that of 2D fast spin echo T2-weighted images (2D T2 FSE) for the evaluation of the CFL, and whether 3D VISTA can replace 2D T2 FSE for the evaluation of CFL injuries. This retrospective study included 76 patients who underwent ankle MRI with CFL views of both 2D T2 FSE MRI and 3D VISTA. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of both techniques were measured. The anatomical identification score and diagnostic performances were evaluated by two readers independently. The diagnostic performances of 3D VISTA and 2D T2 FSE were analysed by sensitivity, specificity, and accuracy for diagnosing CFL injury with reference standards of surgically or clinically confirmed diagnoses. Surgical correlation was performed in 29% of the patients, and clinical examination was used in those who did not have surgery (71%). The SNRs and CNRs of 3D VISTA were significantly higher than those of 2D T2 FSE. The anatomical identification scores on 3D VISTA were inferior to those on 2D T2 FSE, and the differences were statistically significant (p<0.05). There were no significant differences in diagnostic performance between the two sequences when diagnoses were classified as normal or abnormal. Although the image quality of 3D VISTA MRI of the CFL view is not equal to that of 2D T2 FSE for the anatomical evaluation of CFL, 3D VISTA has a diagnostic performance comparable to that of 2D T2 FSE for the diagnosis of CFL injuries. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. [MRI in chronic epicondylitis humeri radialis using 1.0 T equipment--contrast medium administration necessary?].

    PubMed

    Herber, S; Kalden, P; Kreitner, K F; Riedel, C; Rompe, J D; Thelen, M

    2001-05-01

    Evaluation of the diagnostic value and confidence of contrast-enhanced MR imaging in patients with lateral epicondylitis in comparison to clinical diagnosis. 42 consecutive patients with clinically proven chronic lateral epicondylitis and 10 elbow joints of healthy controls have been examined on a 1.0 T MR-unit. Criteria for inclusion in the prospective study were: persistent pain and a failed conservative therapy. The MR protocol included STIR sequence, a native, T2-weighted, fat-suppressed TSE sequence, and a Flash-2-D sequence. Also, fat-suppressed, T1-weighted SE sequences before and after administration of Gd-DTPA contrast media have been recorded. In 39/42 patients the STIR sequence showed an increased SI of the common extensor tendon. Increased MR signal of the lateral collateral ligament combined with a thickening and a partial rupture or a full thickness tear have been observed in 15/42 cases. A bone marrow edema at the lateral epicondilus was noticed in 6 of the studied patients and a joint effusion in 18/42 patients. After administration of contrast media we noticed an average increase of SI by about 150%. However, enhanced MR imaging did not provide additional information. In MR imaging of chronic epicondylitis administration of gadolinium-DTPA does not provide additional information.

  8. Fast susceptibility-weighted imaging with three-dimensional short-axis propeller (SAP)-echo-planar imaging.

    PubMed

    Holdsworth, Samantha J; Yeom, Kristen W; Moseley, Michael E; Skare, S

    2015-05-01

    Susceptibility-weighted imaging (SWI) in neuroimaging can be challenging due to long scan times of three-dimensional (3D) gradient recalled echo (GRE), while faster techniques such as 3D interleaved echo-planar imaging (iEPI) are prone to motion artifacts. Here we outline and implement a 3D short-axis propeller echo-planar imaging (SAP-EPI) trajectory as a faster, motion-correctable approach for SWI. Experiments were conducted on a 3T MRI system. The 3D SAP-EPI, 3D iEPI, and 3D GRE SWI scans were acquired on two volunteers. Controlled motion experiments were conducted to test the motion-correction capability of 3D SAP-EPI. The 3D SAP-EPI SWI data were acquired on two pediatric patients as a potential alternative to 2D GRE used clinically. The 3D GRE images had a better target resolution (0.47 × 0.94 × 2 mm, scan time = 5 min), iEPI and SAP-EPI images (resolution = 0.94 × 0.94 × 2 mm) were acquired in a faster scan time (1:52 min) with twice the brain coverage. SAP-EPI showed motion-correction capability and some immunity to undersampling from rejected data. While 3D SAP-EPI suffers from some geometric distortion, its short scan time and motion-correction capability suggest that SAP-EPI may be a useful alternative to GRE and iEPI for use in SWI, particularly in uncooperative patients. © 2014 Wiley Periodicals, Inc.

  9. Histogram analysis of T2*-based pharmacokinetic imaging in cerebral glioma grading.

    PubMed

    Liu, Hua-Shan; Chiang, Shih-Wei; Chung, Hsiao-Wen; Tsai, Ping-Huei; Hsu, Fei-Ting; Cho, Nai-Yu; Wang, Chao-Ying; Chou, Ming-Chung; Chen, Cheng-Yu

    2018-03-01

    To investigate the feasibility of histogram analysis of the T2*-based permeability parameter volume transfer constant (K trans ) for glioma grading and to explore the diagnostic performance of the histogram analysis of K trans and blood plasma volume (v p ). We recruited 31 and 11 patients with high- and low-grade gliomas, respectively. The histogram parameters of K trans and v p , derived from the first-pass pharmacokinetic modeling based on the T2* dynamic susceptibility-weighted contrast-enhanced perfusion-weighted magnetic resonance imaging (T2* DSC-PW-MRI) from the entire tumor volume, were evaluated for differentiating glioma grades. Histogram parameters of K trans and v p showed significant differences between high- and low-grade gliomas and exhibited significant correlations with tumor grades. The mean K trans derived from the T2* DSC-PW-MRI had the highest sensitivity and specificity for differentiating high-grade gliomas from low-grade gliomas compared with other histogram parameters of K trans and v p . Histogram analysis of T2*-based pharmacokinetic imaging is useful for cerebral glioma grading. The histogram parameters of the entire tumor K trans measurement can provide increased accuracy with additional information regarding microvascular permeability changes for identifying high-grade brain tumors. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Automated segmentation of multifocal basal ganglia T2*-weighted MRI hypointensities

    PubMed Central

    Glatz, Andreas; Bastin, Mark E.; Kiker, Alexander J.; Deary, Ian J.; Wardlaw, Joanna M.; Valdés Hernández, Maria C.

    2015-01-01

    Multifocal basal ganglia T2*-weighted (T2*w) hypointensities, which are believed to arise mainly from vascular mineralization, were recently proposed as a novel MRI biomarker for small vessel disease and ageing. These T2*w hypointensities are typically segmented semi-automatically, which is time consuming, associated with a high intra-rater variability and low inter-rater agreement. To address these limitations, we developed a fully automated, unsupervised segmentation method for basal ganglia T2*w hypointensities. This method requires conventional, co-registered T2*w and T1-weighted (T1w) volumes, as well as region-of-interest (ROI) masks for the basal ganglia and adjacent internal capsule generated automatically from T1w MRI. The basal ganglia T2*w hypointensities were then segmented with thresholds derived with an adaptive outlier detection method from respective bivariate T2*w/T1w intensity distributions in each ROI. Artefacts were reduced by filtering connected components in the initial masks based on their standardised T2*w intensity variance. The segmentation method was validated using a custom-built phantom containing mineral deposit models, i.e. gel beads doped with 3 different contrast agents in 7 different concentrations, as well as with MRI data from 98 community-dwelling older subjects in their seventies with a wide range of basal ganglia T2*w hypointensities. The method produced basal ganglia T2*w hypointensity masks that were in substantial volumetric and spatial agreement with those generated by an experienced rater (Jaccard index = 0.62 ± 0.40). These promising results suggest that this method may have use in automatic segmentation of basal ganglia T2*w hypointensities in studies of small vessel disease and ageing. PMID:25451469

  11. MR images of mouse brain using clinical 3T MR scanner and 4CH-Mouse coil

    NASA Astrophysics Data System (ADS)

    Lim, Soo Mee; Park, Eun Mi; Lyoo, In Kyoon; Lee, Junghyun; Han, Bo Mi; Lee, Jeong Kyong; Lee, Su Bin

    2015-07-01

    Objectives: Although small-bore high-field magnets are useful for research in small rodent models,this technology, however, has not been easily accessible to most researchers. This current study, thus,tried to evaluate the usability of 4CH-Mouse coil (Philips Healthcare, Best, the Netherlands) forpreclinical investigations in clinical 3T MR scan environment. We evaluated the effects of ischemicpreconditioning (IP) in the mouse stroke model with clinical 3T MR scanner and 4CH-Mouse coil. Materials and Methods: Experiments were performed on male C57BL/6 mice that either received the IP or sham operation (control). Three different MR sequences including diffusion weighted images (DWI), T2-weighted images (T2WI), and fluid attenuated inversion recovery (FLAIR) were performed on the mouse brains following 24, 72 hours of middle cerebral artery occlusion (MCAO) and analyzed for infarct lesions. Results: The images showed that the IP-treated mouse brains had significantly smaller infarct volumes compared to the control group. Of the MR sequences employed, the T2WI showed the highest level of correlations with postmortem infarct volume measurements. Conclusions: The clinical 3T MR scanner turned out to have a solid potential as a practical tool for imaging small animal brains. MR sequences including DWI, T2WI, FLAIR were obtained with acceptable resolution and in a reasonable time constraint in evaluating a mouse stroke model brain.

  12. Development of Bifunctional Gadolinium-Labeled Superparamagnetic Nanoparticles (Gd-MnMEIO) for In Vivo MR Imaging of the Liver in an Animal Model.

    PubMed

    Kuo, Yu-Ting; Chen, Chiao-Yun; Liu, Gin-Chung; Wang, Yun-Ming

    2016-01-01

    Liver tumors are common and imaging methods, particularly magnetic resonance imaging (MRI), play an important role in their non-invasive diagnosis. Previous studies have shown that detection of liver tumors can be improved by injection of two different MR contrast agents. Here, we developed a new contrast agent, Gd-manganese-doped magnetism-engineered iron oxide (Gd-MnMEIO), with enhancement effects on both T1- and T2-weighted MR images of the liver. A 3.0T clinical MR scanner equipped with transmit/receiver coil for mouse was used to obtain both T1-weighted spoiled gradient-echo and T2-weighted fast spin-echo axial images of the liver before and after intravenous contrast agent injection into Balb/c mice with and without tumors. After pre-contrast scanning, six mice per group were intravenously injected with 0.1 mmol/kg Gd-MnMEIO, or the control agents, i.e., Gd-DTPA or SPIO. The scanning time points for T1-weighted images were 0.5, 5, 10, 15, 20, 25, and 30 min after contrast administration. The post-enhanced T2-weighted images were then acquired immediately after T1-weighted acquisition. We found that T1-weighted images were positively enhanced by both Gd-DTPA and Gd-MnMEIO and negatively enhanced by SPIO. The enhancement by both Gd-DTPA and Gd-MnMEIO peaked at 0.5 min and gradually declined thereafter. Gd-MnMEIO (like Gd-DTPA) enhanced T1-weighted images and (like SPIO) T2-weighted images. Marked vascular enhancement was clearly visible on dynamic T1-weighted images with Gd-MnMEIO. In addition, the T2 signal was significantly decreased at 30 min after administration of Gd-MnMEIO. Whereas the effects of Gd-MnMEIO and SPIO on T2-weighted images were similar (p = 0.5824), those of Gd-MnMEIO and Gd-DTPA differed, with Gd-MnMEIO having a significant T2 contrast effect (p = 0.0086). Our study confirms the feasibility of synthesizing an MR contrast agent with both T1 and T2 shortening effects and using such an agent in vivo. This agent enables tumor detection and

  13. Optimization image of magnetic resonance imaging (MRI) T2 fast spin echo (FSE) with variation echo train length (ETL) on the rupture tendon achilles case

    NASA Astrophysics Data System (ADS)

    Muzamil, Akhmad; Haries Firmansyah, Achmad

    2017-05-01

    The research was done the optimization image of Magnetic Resonance Imaging (MRI) T2 Fast Spin Echo (FSE) with variation Echo Train Length (ETL) on the Rupture Tendon Achilles case. This study aims to find the variations Echo Train Length (ETL) from the results of ankle’s MRI image and find out how the value of Echo Train Length (ETL) works on the MRI ankle to produce optimal image. In this research, the used ETL variations were 12 and 20 with the interval 2 on weighting T2 FSE sagittal. The study obtained the influence of Echo Train Length (ETL) on the quality of ankle MRI image sagittal using T2 FSE weighting and analyzed in 25 images of five patients. The data analysis has done quantitatively with the Region of Interest (ROI) directly on computer MRI image planes which conducted statistical tests Signal to Noise Ratio (SNR) and Contras to Noise Ratio (CNR). The Signal to Noise Ratio (SNR) was the highest finding on fat tissue, while the Contras to Noise Ratio (CNR) on the Tendon-Fat tissue with ETL 12 found in two patients. The statistics test showed the significant SNR value of the 0.007 (p<0.05) of Tendon tissue, 0.364 (p>0.05) of the Fat, 0.912 (p>0.05) of the Fibula, and 0.436 (p>0.05) of the Heel Bone. For the contrast to noise ratio (CNR) of the Tendon-FAT tissue was about 0.041 (p>0.05). The results of the study showed that ETL variation with T2 FSE sagittal weighting had difference at Tendon tissue and Tendon-Fat tissue for MRI imaging quality. SNR and CNR were an important aspect on imaging optimization process to give the diagnose information.

  14. Effect of eicosapentaenoic acid/docosahexaenoic acid on coronary high-intensity plaques detected with non-contrast T1-weighted imaging (the AQUAMARINE EPA/DHA study): study protocol for a randomized controlled trial.

    PubMed

    Nakao, Kazuhiro; Noguchi, Teruo; Asaumi, Yasuhide; Morita, Yoshiaki; Kanaya, Tomoaki; Fujino, Masashi; Hosoda, Hayato; Yoneda, Shuichi; Kawakami, Shoji; Nagai, Toshiyuki; Nishihira, Kensaku; Nakashima, Takahiro; Kumasaka, Reon; Arakawa, Tetsuo; Otsuka, Fumiyuki; Nakanishi, Michio; Kataoka, Yu; Tahara, Yoshio; Goto, Yoichi; Yamamoto, Haruko; Hamasaki, Toshimitsu; Yasuda, Satoshi

    2018-01-08

    Despite the success of HMG-CoA reductase inhibitor (statin) therapy in reducing atherosclerotic cardiovascular events, a residual risk for cardiovascular events in patients with coronary artery disease (CAD) remains. Long-chain n-3 polyunsaturated fatty acids (LC n-3 PUFAs), especially eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), are promising anti-atherosclerosis agents that might reduce the residual CAD risk. Non-contrast T1-weighted imaging (T1WI) with cardiac magnetic resonance (CMR) less invasively identifies high-risk coronary plaques as high-intensity signals. These high-intensity plaques (HIPs) are quantitatively assessed using the plaque-to-myocardium signal intensity ratio (PMR). Our goal is to assess the effect of EPA/DHA on coronary HIPs detected with T1WI in patients with CAD on statin treatment. This prospective, controlled, randomized, open-label study examines the effect of 12 months of EPA/DHA therapy and statin treatment on PMR of HIPs detected with CMR and computed tomography angiography (CTA) in patients with CAD. The primary endpoint is the change in PMR after EPA/DHA treatment. Secondary endpoints include changes in Hounsfield units, plaque volume, vessel area, and plaque area measured using CTA. Subjects are randomly assigned to either of three groups: the 2 g/day EPA/DHA group, the 4 g/day EPA/DHA group, or the no-treatment group. This trial will help assess whether EPA/DHA has an anti-atherosclerotic effect using PMR of HIPs detected by CMR. The trial outcomes will provide novel insights into the effect of EPA/DHA on high-risk coronary plaques and may provide new strategies for lowering the residual risk in patients with CAD on statin therapy. The University Hospital Medical Information Network (UMIN) Clinical Trials Registry, ID: UMIN000015316 . Registered on 2 October 2014.

  15. Accelerated T1ρ acquisition for knee cartilage quantification using compressed sensing and data-driven parallel imaging: A feasibility study.

    PubMed

    Pandit, Prachi; Rivoire, Julien; King, Kevin; Li, Xiaojuan

    2016-03-01

    Quantitative T1ρ imaging is beneficial for early detection for osteoarthritis but has seen limited clinical use due to long scan times. In this study, we evaluated the feasibility of accelerated T1ρ mapping for knee cartilage quantification using a combination of compressed sensing (CS) and data-driven parallel imaging (ARC-Autocalibrating Reconstruction for Cartesian sampling). A sequential combination of ARC and CS, both during data acquisition and reconstruction, was used to accelerate the acquisition of T1ρ maps. Phantom, ex vivo (porcine knee), and in vivo (human knee) imaging was performed on a GE 3T MR750 scanner. T1ρ quantification after CS-accelerated acquisition was compared with non CS-accelerated acquisition for various cartilage compartments. Accelerating image acquisition using CS did not introduce major deviations in quantification. The coefficient of variation for the root mean squared error increased with increasing acceleration, but for in vivo measurements, it stayed under 5% for a net acceleration factor up to 2, where the acquisition was 25% faster than the reference (only ARC). To the best of our knowledge, this is the first implementation of CS for in vivo T1ρ quantification. These early results show that this technique holds great promise in making quantitative imaging techniques more accessible for clinical applications. © 2015 Wiley Periodicals, Inc.

  16. The Value of Diffusion-Weighted Imaging in Combination With Conventional Magnetic Resonance Imaging for Improving Tumor Detection for Early Cervical Carcinoma Treated With Fertility-Sparing Surgery.

    PubMed

    Li, Xiulei; Wang, Ling; Li, Yong; Song, Peiji

    2017-10-01

    This study aimed to investigate the value of diffusion-weighted imaging (DWI) in combination with conventional magnetic resonance imaging (MRI) for improving tumor detection in young patients treated with fertility-sparing surgery because of early cervical carcinoma. Fifty-four patients with stage Ia or Ib1 cervical carcinoma were enrolled into this study. Magnetic resonance examinations were performed for these patients using conventional MRI (including T1-weighted imaging, T2-weighted imaging, and dynamic contrast-enhanced MRI) and DWI. The apparent diffusion coefficient (ADC) values of cervical carcinoma were analyzed quantitatively and compared with that of adjacent epithelium. Sensitivity, positive predictive value, and accuracy of 2 sets of MRI sequences were calculated on the basis of histologic results, and the diagnostic ability of conventional MRI/DWI combinations was compared with that of conventional MRI. The mean ADC value from cervical carcinoma (mean, 786 × 10 mm/s ± 100) was significantly lower than that from adjacent epithelium (mean, 1352 × 10 mm/s ± 147) (P = 0.01). When the threshold ADC value set as 1010 × 10 mm/s, the sensitivity and specificity for differentiating cervical carcinoma from nontumor epithelium were 78.2% and 67.2%, respectively. The sensitivity and accuracy of conventional MRI for tumor detection were 76.0% and 70.4%, whereas the sensitivity and accuracy of conventional MRI/DWI combinations were 91.7% and 90.7%, respectively. Conventional MRI/DWI combinations revealed a positive predictive value of 97.8% and only 4 false-negative findings. The addition of DWI to conventional MRI considerably improves the sensitivity and accuracy of tumor detection in young patients treated with fertility-sparing surgery, which supports the inclusion quantitative analysis of ADC value in routine MRI protocol before fertility-sparing surgery.

  17. Ultrahigh-resolution imaging of the human brain with phase-cycled balanced steady-state free precession at 7 T.

    PubMed

    Zeineh, Michael M; Parekh, Mansi B; Zaharchuk, Greg; Su, Jason H; Rosenberg, Jarrett; Fischbein, Nancy J; Rutt, Brian K

    2014-05-01

    The objectives of this study were to acquire ultra-high resolution images of the brain using balanced steady-state free precession (bSSFP) at 7 T and to identify the potential utility of this sequence. Eight volunteers participated in this study after providing informed consent. Each volunteer was scanned with 8 phase cycles of bSSFP at 0.4-mm isotropic resolution using 0.5 number of excitations and 2-dimensional parallel acceleration of 1.75 × 1.75. Each phase cycle required 5 minutes of scanning, with pauses between the phase cycles allowing short periods of rest. The individual phase cycles were aligned and then averaged. The same volunteers underwent scanning using 3-dimensional (3D) multiecho gradient recalled echo at 0.8-mm isotropic resolution, 3D Cube T2 at 0.7-mm isotropic resolution, and thin-section coronal oblique T2-weighted fast spin echo at 0.22 × 0.22 × 2.0-mm resolution for comparison. Two neuroradiologists assessed image quality and potential research and clinical utility. The volunteers generally tolerated the scan sessions well, and composite high-resolution bSSFP images were produced for each volunteer. Rater analysis demonstrated that bSSFP had a superior 3D visualization of the microarchitecture of the hippocampus, very good contrast to delineate the borders of the subthalamic nucleus, and relatively good B1 homogeneity throughout. In addition to an excellent visualization of the cerebellum, subtle details of the brain and skull base anatomy were also easier to identify on the bSSFP images, including the line of Gennari, membrane of Liliequist, and cranial nerves. Balanced steady-state free precession had a strong iron contrast similar to or better than the comparison sequences. However, cortical gray-white contrast was significantly better with Cube T2 and T2-weighted fast spin echo. Balanced steady-state free precession can facilitate ultrahigh-resolution imaging of the brain. Although total imaging times are long, the individually short

  18. Brain MR imaging at ultra-low radiofrequency power.

    PubMed

    Sarkar, Subhendra N; Alsop, David C; Madhuranthakam, Ananth J; Busse, Reed F; Robson, Philip M; Rofsky, Neil M; Hackney, David B

    2011-05-01

    To explore the lower limits for radiofrequency (RF) power-induced specific absorption rate (SAR) achievable at 1.5 T for brain magnetic resonance (MR) imaging without loss of tissue signal or contrast present in high-SAR clinical imaging in order to create a potentially viable MR method at ultra-low RF power to image tissues containing implanted devices. An institutional review board-approved HIPAA-compliant prospective MR study design was used, with written informed consent from all subjects prior to MR sessions. Seven healthy subjects were imaged prospectively at 1.5 T with ultra-low-SAR optimized three-dimensional (3D) fast spin-echo (FSE) and fluid-attenuated inversion-recovery (FLAIR) T2-weighted sequences and an ultra-low-SAR 3D spoiled gradient-recalled acquisition in the steady state T1-weighted sequence. Corresponding high-SAR two-dimensional (2D) clinical sequences were also performed. In addition to qualitative comparisons, absolute signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) for multicoil, parallel imaging acquisitions were generated by using a Monte Carlo method for quantitative comparison between ultra-low-SAR and high-SAR results. There were minor to moderate differences in the absolute tissue SNR and CNR values and in qualitative appearance of brain images obtained by using ultra-low-SAR and high-SAR techniques. High-SAR 2D T2-weighted imaging produced slightly higher SNR, while ultra-low-SAR 3D technique not only produced higher SNR for T1-weighted and FLAIR images but also higher CNRs for all three sequences for most of the brain tissues. The 3D techniques adopted here led to a decrease in the absorbed RF power by two orders of magnitude at 1.5 T, and still the image quality was preserved within clinically acceptable imaging times. RSNA, 2011

  19. Synthesis of Ferromagnetic Fe0.6 Mn0.4 O Nanoflowers as a New Class of Magnetic Theranostic Platform for In Vivo T1 -T2 Dual-Mode Magnetic Resonance Imaging and Magnetic Hyperthermia Therapy.

    PubMed

    Liu, Xiao Li; Ng, Cheng Teng; Chandrasekharan, Prashant; Yang, Hai Tao; Zhao, Ling Yun; Peng, Erwin; Lv, Yun Bo; Xiao, Wen; Fang, Jie; Yi, Jia Bao; Zhang, Huan; Chuang, Kai-Hsiang; Bay, Boon Huat; Ding, Jun; Fan, Hai Ming

    2016-08-01

    Uniform wüstite Fe0.6 Mn0.4 O nanoflowers have been successfully developed as an innovative theranostic agent with T1 -T2 dual-mode magnetic resonance imaging (MRI), for diagnostic applications and therapeutic interventions via magnetic hyperthermia. Unlike their antiferromagnetic bulk counterpart, the obtained Fe0.6 Mn0.4 O nanoflowers show unique room-temperature ferromagnetic behavior, probably due to the presence of an exchange coupling effect. Combined with the flower-like morphology, ferromagnetic Fe0.6 Mn0.4 O nanoflowers are demonstrated to possess dual-modal MRI sensitivity, with longitudinal relaxivity r1 and transverse relaxivity r2 as high as 4.9 and 61.2 mm(-1) s(-1) [Fe]+[Mn], respectively. Further in vivo MRI carried out on the mouse orthotopic glioma model revealed gliomas are clearly delineated in both T1 - and T2 -weighted MR images, after administration of the Fe0.6 Mn0.4 O nanoflowers. In addition, the Fe0.6 Mn0.4 O nanoflowers also exhibit excellent magnetic induction heating effects. Both in vitro and in vivo magnetic hyperthermia experimentation has demonstrated that magnetic hyperthermia by using the innovative Fe0.6 Mn0.4 O nanoflowers can induce MCF-7 breast cancer cell apoptosis and a complete tumor regression without appreciable side effects. The results have demonstrated that the innovative Fe0.6 Mn0.4 O nanoflowers can be a new magnetic theranostic platform for in vivo T1 -T2 dual-mode MRI and magnetic thermotherapy, thereby achieving a one-stop diagnosis cum effective therapeutic modality in cancer management. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Investigation of cyano-bridged coordination nanoparticles Gd3+/[Fe(CN)6]3-/d-mannitol as T1-weighted MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Perrier, M.; Gallud, A.; Ayadi, A.; Kennouche, S.; Porredon, C.; Gary-Bobo, M.; Larionova, J.; Goze-Bac, Ch.; Zanca, M.; Garcia, M.; Basile, I.; Long, J.; de Lapuente, J.; Borras, M.; Guari, Y.

    2015-07-01

    Cyano-bridged Gd3+/[Fe(CN)6]3- coordination polymer nanoparticles of 3-4 nm stabilized with d-mannitol presenting a high r1 relaxivity value of 11.4 mM-1 s-1 were investigated in vivo as contrast agents (CA) for Magnetic Resonance Imaging (MRI). They allow an increase of the MR image contrast and can act as an efficient intravascular T1 CA with a relatively long blood-circulation lifetime (60 min) without specific toxicity.Cyano-bridged Gd3+/[Fe(CN)6]3- coordination polymer nanoparticles of 3-4 nm stabilized with d-mannitol presenting a high r1 relaxivity value of 11.4 mM-1 s-1 were investigated in vivo as contrast agents (CA) for Magnetic Resonance Imaging (MRI). They allow an increase of the MR image contrast and can act as an efficient intravascular T1 CA with a relatively long blood-circulation lifetime (60 min) without specific toxicity. Electronic supplementary information (ESI) available: Experimental details and procedures, toxicological data, physical characterization. See DOI: 10.1039/c5nr01557j

  1. Weight status and body image perceptions in adolescents: current perspectives.

    PubMed

    Voelker, Dana K; Reel, Justine J; Greenleaf, Christy

    2015-01-01

    Adolescence represents a pivotal stage in the development of positive or negative body image. Many influences exist during the teen years including transitions (eg, puberty) that affect one's body shape, weight status, and appearance. Weight status exists along a spectrum between being obese (ie, where one's body weight is in the 95th percentile for age and gender) to being underweight. Salient influences on body image include the media, which can target adolescents, and peers who help shape beliefs about the perceived body ideal. Internalization of and pressures to conform to these socially prescribed body ideals help to explain associations between weight status and body image. The concepts of fat talk and weight-related bullying during adolescence greatly contribute to an overemphasis on body weight and appearance as well as the development of negative body perceptions and dissatisfaction surrounding specific body parts. This article provides an overview of the significance of adolescent development in shaping body image, the relationship between body image and adolescent weight status, and the consequences of having a negative body image during adolescence (ie, disordered eating, eating disorders, and dysfunctional exercise). Practical implications for promoting a healthy weight status and positive body image among adolescents will be discussed.

  2. Weight status and body image perceptions in adolescents: current perspectives

    PubMed Central

    Voelker, Dana K; Reel, Justine J; Greenleaf, Christy

    2015-01-01

    Adolescence represents a pivotal stage in the development of positive or negative body image. Many influences exist during the teen years including transitions (eg, puberty) that affect one’s body shape, weight status, and appearance. Weight status exists along a spectrum between being obese (ie, where one’s body weight is in the 95th percentile for age and gender) to being underweight. Salient influences on body image include the media, which can target adolescents, and peers who help shape beliefs about the perceived body ideal. Internalization of and pressures to conform to these socially prescribed body ideals help to explain associations between weight status and body image. The concepts of fat talk and weight-related bullying during adolescence greatly contribute to an overemphasis on body weight and appearance as well as the development of negative body perceptions and dissatisfaction surrounding specific body parts. This article provides an overview of the significance of adolescent development in shaping body image, the relationship between body image and adolescent weight status, and the consequences of having a negative body image during adolescence (ie, disordered eating, eating disorders, and dysfunctional exercise). Practical implications for promoting a healthy weight status and positive body image among adolescents will be discussed. PMID:26347007

  3. Optimization and Clinical Feasibility of Free-breathing Diffusion-weighted Imaging of the Liver: Comparison with Respiratory-Triggered Diffusion-weighted Imaging.

    PubMed

    Takayama, Yukihisa; Nishie, Akihiro; Asayama, Yoshiki; Ishigami, Kousei; Kakihara, Daisuke; Ushijima, Yasuhiro; Fujita, Nobuhiro; Yoshiura, Takashi; Takemura, Atsushi; Obara, Makoto; Takahara, Taro; Honda, Hiroshi

    2015-01-01

    We compared the image quality of free-breathing diffusion-weighted imaging (FB-DWI) to that of respiratory-triggered DWI (RT-DWI) after proper optimization. Three healthy subjects were scanned to optimize magnetic resonance (MR) parameters of FB-DWI to improve image quality, including spatial resolution, image noise, and chemical shift artifacts. After this optimization, we scanned 32 patients with liver disease to assess the clinical feasibility of the optimized FB-DWI. Of the 32 patients, 14 had a total of 28 hepatocellular carcinomas (HCCs), four had a total of 15 metastatic liver tumors, and the other 14 had no tumor. Qualitatively, we compared the image quality scores of FB-DWI with those of RT-DWI with the Wilcoxon signed-rank test. Quantitatively, we compared the signal-to-noise ratios (SNRs) of the liver parenchyma, lesion-to-nonlesion contrast-to-noise ratios (CNRs) and apparent diffusion coefficient (ADC) values of the liver parenchyma and liver tumor by the paired t-test. The average scores of image quality for sharpness of liver contour, image noise, and chemical shift artifacts were significantly higher for FB-DWI than RT-DWI (P < 0.05). SNRs, CNRs, and ADC values of the liver parenchyma and tumors did not differ significantly between the 2 DWI methods. Compared with RT-DWI, the optimized FB-DWI provided better spatial resolution, fewer artifacts, and comparable SNRs, lesion-to-nonlesion CNRs, and ADC values.

  4. Investigation of contrast-enhanced subtracted breast CT images with MAP-EM based on projection-based weighting imaging.

    PubMed

    Zhou, Zhengdong; Guan, Shaolin; Xin, Runchao; Li, Jianbo

    2018-06-01

    Contrast-enhanced subtracted breast computer tomography (CESBCT) images acquired using energy-resolved photon counting detector can be helpful to enhance the visibility of breast tumors. In such technology, one challenge is the limited number of photons in each energy bin, thereby possibly leading to high noise in separate images from each energy bin, the projection-based weighted image, and the subtracted image. In conventional low-dose CT imaging, iterative image reconstruction provides a superior signal-to-noise compared with the filtered back projection (FBP) algorithm. In this paper, maximum a posteriori expectation maximization (MAP-EM) based on projection-based weighting imaging for reconstruction of CESBCT images acquired using an energy-resolving photon counting detector is proposed, and its performance was investigated in terms of contrast-to-noise ratio (CNR). The simulation study shows that MAP-EM based on projection-based weighting imaging can improve the CNR in CESBCT images by 117.7%-121.2% compared with FBP based on projection-based weighting imaging method. When compared with the energy-integrating imaging that uses the MAP-EM algorithm, projection-based weighting imaging that uses the MAP-EM algorithm can improve the CNR of CESBCT images by 10.5%-13.3%. In conclusion, MAP-EM based on projection-based weighting imaging shows significant improvement the CNR of the CESBCT image compared with FBP based on projection-based weighting imaging, and MAP-EM based on projection-based weighting imaging outperforms MAP-EM based on energy-integrating imaging for CESBCT imaging.

  5. Ultra-high field upper extremity peripheral nerve and non-contrast enhanced vascular imaging

    PubMed Central

    Raval, Shailesh B.; Britton, Cynthia A.; Zhao, Tiejun; Krishnamurthy, Narayanan; Santini, Tales; Gorantla, Vijay S.; Ibrahim, Tamer S.

    2017-01-01

    Objective The purpose of this study was to explore the efficacy of Ultra-high field [UHF] 7 Tesla [T] MRI as compared to 3T MRI in non-contrast enhanced [nCE] imaging of structural anatomy in the elbow, forearm, and hand [upper extremity]. Materials and method A wide range of sequences including T1 weighted [T1] volumetric interpolate breath-hold exam [VIBE], T2 weighted [T2] double-echo steady state [DESS], susceptibility weighted imaging [SWI], time-of-flight [TOF], diffusion tensor imaging [DTI], and diffusion spectrum imaging [DSI] were optimized and incorporated with a radiofrequency [RF] coil system composed of a transverse electromagnetic [TEM] transmit coil combined with an 8-channel receive-only array for 7T upper extremity [UE] imaging. In addition, Siemens optimized protocol/sequences were used on a 3T scanner and the resulting images from T1 VIBE and T2 DESS were compared to that obtained at 7T qualitatively and quantitatively [SWI was only qualitatively compared]. DSI studio was utilized to identify nerves based on analysis of diffusion weighted derived fractional anisotropy images. Images of forearm vasculature were extracted using a paint grow manual segmentation method based on MIPAV [Medical Image Processing, Analysis, and Visualization]. Results High resolution and high quality signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]—images of the hand, forearm, and elbow were acquired with nearly homogeneous 7T excitation. Measured [performed on the T1 VIBE and T2 DESS sequences] SNR and CNR values were almost doubled at 7T vs. 3T. Cartilage, synovial fluid and tendon structures could be seen with higher clarity in the 7T T1 and T2 weighted images. SWI allowed high resolution and better quality imaging of large and medium sized arteries and veins, capillary networks and arteriovenous anastomoses at 7T when compared to 3T. 7T diffusion weighted sequence [not performed at 3T] demonstrates that the forearm nerves are clearly delineated by

  6. Black TiO2-based nanoprobes for T1-weighted MRI-guided photothermal therapy in CD133 high expressed pancreatic cancer stem-like cells.

    PubMed

    Wang, Siqi; Ren, Wenzhi; Wang, Jianhua; Jiang, Zhenqi; Saeed, Madiha; Zhang, Lili; Li, Aiguo; Wu, Aiguo

    2018-06-27

    At present, transmembrane glycoprotein CD133 highly expressed pancreatic cancer stem cells (PCSCs), with the features of chemotherapeutic/radiotherapeutic resistance and exclusive tumorigenic potential, are considered as the primary cause of metastasis and recurrence in pancreatic cancer, and therefore are an effective target in the disease treatment. Furthermore, with the launch of precision medicine, multifunctional nanoprobes have been applied as an efficient strategy for the magnetic resonance imaging (MRI)-guided photothermal therapy (PTT) of pancreatic cancer. In this research, with the aim of achieving precise MRI-guided PTT in CD133 highly expressed PCSCs, novel bTiO2-Gd-CD133mAb nanoprobes were designed and successfully prepared by loading Gd-DOTA and CD133 monoclonal antibodies on black TiO2 nanoparticles. It was very interesting to find that the r1 relaxivity value of the nanoprobes was 34.394 mM-1 s-1, about 7.5 times that of commercial Magnevist (4.5624 mM-1 s-1), which indicates that the nanoprobes have good potential as MRI T1 contrast agents with excellent performance. Herein, CD133 highly expressed PANC-1 cells were selected and verified as PCSCs model. In vitro experiments demonstrated that the nanoprobes exhibited active-targeting ability in PANC-1 cells, and consequently could specially enhance T1-weighted MR imaging and 808 nm near-infrared (NIR)-triggered PTT efficiency in the PCSCs model. Our study not only provides a new strategy for the effective treatment of pancreatic cancer and its' stem cells, but also further broadens the application of black TiO2 in the field of cancer theranostics.

  7. Subaru Near Infrared Coronagraphic Images of T Tauri

    NASA Astrophysics Data System (ADS)

    Mayama, Satoshi; Tamura, Motohide; Hayashi, Masahiko; Itoh, Yoichi; Fukagawa, Misato; Suto, Hiroshi; Ishii, Miki; Murakawa, Koji; Oasa, Yumiko; Hayashi, Saeko S.; Yamashita, Takuya; Morino, Junichi; Oya, Shin; Naoi, Takahiro; Pyo, Tae-Soo; Nishikawa, Takayuki; Kudo, Tomoyuki; Usuda, Tomonori; Ando, Hiroyasu; Miyama, Shoken M.; Kaifu, Norio

    2006-04-01

    High angular resolution near-infrared (JHK) adaptive optics images of T Tau were obtained with the infrared camera Coronagraphic Imager with Adaptive Optics (CIAO) mounted on the 8.2m Subaru Telescope in 2002 and 2004. The images resolve a complex circumstellar structure around a multiple system. We resolved T Tau Sa and Sb as well as T Tau N and S. The estimated orbit of T Tau Sb indicates that it is probably bound to T Tau Sa. The K band flux of T Tau S decreased by ˜ 1.7 Jy in 2002 November compared with that in 2001 mainly because T Tau Sa became fainter. The arc-like ridge detected in our near-infrared images is consistent with what is seen at visible wavelengths, supporting the interpretation in previous studies that the arc is part of the cavity wall seen relatively pole-on. Halo emission is detected out to ˜2''from T Tau N. This may be light scattered off the common envelope surrounding the T Tauri multiple system.

  8. Body Weight and Body Image

    PubMed Central

    Olmsted, Marion P; McFarlane, Traci

    2004-01-01

    Health Issue Body weight is of physical and psychological importance to Canadian women; it is associated with health status, physical activity, body image, and self-esteem. Although the problems associated with overweight and obesity are indeed serious, there are also problems connected to being underweight. Weight prejudice and the dieting industry intensify body image concerns for Canadian women and can have a major negative impact on self-esteem. Key Findings Women have lower BMIs than men, a lower incidence of being overweight and a higher incidence of being underweight. However, women across all weight categories are more dissatisfied with their bodies. Sixty percent of women are inactive, and women with a BMI of 27 or higher are more likely to be inactive than women with lower BMIs. The data show that women are aware of the health benefits of exercise, but there is a gap between knowledge and practice. When asked about barriers to health improvement, 39.7% of women cited lack of time and 39.2% lack of willpower. Data Gaps and Recommendations Weight prejudice must be made unacceptable and positive body image should be encouraged and diversity valued. Health policies should encourage healthy eating and healthy activity. Health curricula for young students should include information about healthy eating, active lifestyle, and self-esteem. Physical activities that mothers can participate in with their families should be encouraged. Research should be funded to elucidate the most effective methods of getting women to become and remain physically active without focusing on appearance. PMID:15345068

  9. Magnetic Resonance Imaging in Patients With Mechanical Low Back Pain Using a Novel Rapid-Acquisition Three-Dimensional SPACE Sequence at 1.5-T: A Pilot Study Comparing Lumbar Stenosis Assessment With Routine Two-Dimensional Magnetic Resonance Sequences.

    PubMed

    Swami, Vimarsha G; Katlariwala, Mihir; Dhillon, Sukhvinder; Jibri, Zaid; Jaremko, Jacob L

    2016-11-01

    To minimize the burden of overutilisation of lumbar spine magnetic resonance imaging (MRI) on a resource-constrained public healthcare system, it may be helpful to image some patients with mechanical low-back pain (LBP) using a simplified rapid MRI screening protocol at 1.5-T. A rapid-acquisition 3-dimensional (3D) SPACE (Sampling Perfection with Application-optimized Contrasts using different flip angle Evolution) sequence can demonstrate common etiologies of LBP. We compared lumbar spinal canal stenosis (LSCS) and neural foraminal stenosis (LNFS) assessment on 3D SPACE against conventional 2-dimensional (2D) MRI. We prospectively performed 3D SPACE and 2D spin-echo MRI sequences (axial or sagittal T1-weighted or T2-weighted) at 1.5-T in 20 patients. Two blinded readers assessed levels L3-4, L4-5 and L5-S1 using: 1) morphologic grading systems, 2) global impression on the presence or absence of clinically significant stenosis (n = 60 disc levels for LSCS, n = 120 foramina for LNFS). Reliability statistics were calculated. Acquisition time was ∼5 minutes for SPACE and ∼20 minutes for 2D MRI sequences. Interobserver agreement of LSCS was substantial to near perfect on both sequences (morphologic grading: kappa [k] = 0.71 SPACE, k = 0.69 T2-weighted; global impression: k = 0.85 SPACE, k = 0.78 T2-weighted). LNFS assessment had superior interobserver reliability using SPACE than T1-weighted (k = 0.54 vs 0.37). Intersequence agreement of findings between SPACE and 2D MRI was substantial to near perfect by global impression (LSCS: k = 0.78 Reader 1, k = 0.85 Reader 2; LNFS: k = 0.63 Reader 1, k = 0.66 Reader 2). 3D SPACE was acquired in one-quarter the time as the conventional 2D MRI protocol, had excellent agreement with 2D MRI for stenosis assessment, and had interobserver reliability superior to 2D MRI. These results justify future work to explore the role of 3D SPACE in a rapid MRI screening protocol at 1.5-T for mechanical LBP. Copyright

  10. T1 hyperintense disc in alkaptonuria.

    PubMed

    Sag, Alan A; Silbergleit, Richard; Olson, Rick E; Wilson, Jon; Krishnan, Anant

    2012-10-01

    Case report. To report a rare case of alkaptonuria presenting as a T1-hyperintense disc herniation. A 46-year-old man without previous diagnosis of alkaptonuria underwent evaluation for progressive back pain revealing a T1-hyperintense disc herniation at the L3-L4 level. Discectomy recovered a blackened disc that was pathologically confirmed to be nucleus pulposus with alkaptonuric involvement. The differential diagnosis of a T1-hyperintense, T2-hypointense disc on magnetic resonance imaging is discussed, with emphasis on the pathophysiology of alkaptonuria. A single patient is reported. Pathologically proven patient presentation with radiological and pathological images. We report a rare case of alkaptonuria presenting as a T1-hyperintense disc herniation.

  11. Diffusion-weighted imaging of the liver at 3 T using section-selection gradient reversal: emphasis on chemical shift artefacts and lesion conspicuity.

    PubMed

    Lee, J S; Kim, Y K; Jeong, W K; Choi, D; Lee, W J

    2015-04-01

    To assess the value of section-selection gradient reversal (SSGR) in liver diffusion-weighted imaging (DWI) by comparing it to conventional DWI with an emphasis on chemical shift artefacts and lesion conspicuity. Forty-eight patients (29 men and 19 women; age range 33-80 years) with 48 liver lesions underwent two DWI examinations using spectral presaturation with inversion recovery fat suppression with and without SSGR at 3 T. Two reviewers evaluated each DWI (b = 100 and b = 800 image) with respect to chemical shift artefacts and liver lesion conspicuity using five-point scales and performed pairwise comparisons between the two DWIs. The signal-to-noise ratio (SNR) of the liver and the lesion and the lesion-liver contrast-to-noise ratio (CNR) were also calculated. SSGR-DWI was significantly better than conventional DWI with respect to chemical shift artefacts and lesion conspicuity in both separate reviews and pairwise comparisons (p < 0.05). There were significant differences in the SNR of the liver (b = 100 and b = 800 images) and lesion (b = 800) between SSGR-DWI and conventional DWI (p < 0.05). Applying the SSGR method to DWI using SPIR fat suppression at 3 T could significantly reduce chemical shift artefacts without incurring additional acquisition time or SNR penalties, which leads to increased conspicuity of focal liver lesions. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  12. Breath-hold black-blood T1rho mapping improves liver T1rho quantification in healthy volunteers.

    PubMed

    Wáng, Yì Xiáng J; Deng, Min; Lo, Gladys G; Liang, Dong; Yuan, Jing; Chen, Weitian

    2018-03-01

    Background Recent researches suggest that T1rho may be a non-invasive and quantitative technique for detecting and grading liver fibrosis. Purpose To compare a multi-breath-hold bright-blood fast gradient echo (GRE) imaging and a single breath-hold single-shot fast spin echo (FSE) imaging with black-blood effect for liver parenchyma T1rho measurement and to study liver physiological T1rho value in healthy volunteers. Material and Methods The institutional Ethics Committee approved this study. 28 healthy participants (18 men, 10 women; age = 29.6 ± 5.1 years) underwent GRE liver T1rho imaging, and 20 healthy participants (10 men, 10 women; age = 36.9 ± 10.3 years) underwent novel black-blood FSE liver T1rho imaging, both at 3T with spin-lock frequency of 500 Hz. The FSE technique allows simultaneous acquisition of four spin lock times (TSLs; 1 ms, 10 ms, 30 ms, 50msec) in 10 s. Results For FSE technique the intra-scan repeatability intraclass correlation coefficient (ICC) was 0.98; while the inter-scan reproducibility ICC was 0.82 which is better than GRE technique's 0.76. Liver T1rho value in women tended to have a higher value than T1rho values in men (FSE: 42.28 ± 4.06 ms for women and 39.13 ± 2.12 ms for men; GRE: 44.44 ± 1.62 ms for women and 42.36 ± 2.00 ms for men) and FSE technique showed liver T1rho value decreased slightly as age increased. Conclusion Single breath-hold black-blood FSE sequence has better scan-rescan reproducibility than multi-breath-hold bright-blood GRE sequence. Gender and age dependence of liver T1rho in healthy participants is observed, with young women tending to have a higher T1rho measurement.

  13. In Vivo Magnetization Transfer and Diffusion-Weighted Magnetic Resonance Imaging Detects Thrombus Composition in a Mouse Model of Deep Vein Thrombosis

    PubMed Central

    Saha, Prakash; Modarai, Bijan; Smith, Alberto; Botnar, René M.

    2014-01-01

    Background Deep vein thrombosis remains a major health problem necessitating accurate diagnosis. Thrombolysis is associated with significant morbidity and is effective only for the treatment of unorganized thrombus. We tested the feasibility of in vivo magnetization transfer (MT) and diffusion-weighted magnetic resonance imaging to detect thrombus organization in a murine model of deep vein thrombosis. Methods and Results Deep vein thrombosis was induced in the inferior vena cava of male BALB/C mice. Magnetic resonance imaging was performed at days 1, 7, 14, 21, and 28 after thrombus induction using MT, diffusion-weighted, inversion-recovery, and T1-mapping protocols. Delayed enhancement and T1 mapping were repeated 2 hours after injection of a fibrin contrast agent. Finally, excised thrombi were used for histology. We found that MT and diffusion-weighted imaging can detect histological changes associated with thrombus aging. MT rate (MTR) maps and percentage of MT rate (%MTR) allowed visualization and quantification of the thrombus protein content, respectively. The %MTR increased with thrombus organization and was significantly higher at days 14, 21, and 28 after thrombus induction (days 1, 7, 14, 21, 28: %MTR=2483±451, 2079±1210, 7029±2490, 10 295±4356, 32 994±25 449; Panova<0.05). There was a significant positive correlation between the %MTR and the histological protein content of the thrombus (r=0.70; P<0.05). The apparent diffusion coefficient was lower in erythrocyte-rich and collagen-rich thrombus (0.72±0.10 and 0.69±0.05 [×10−3 mm2/s]). Thrombus at days 7 and 14 had the highest apparent diffusion coefficient values (0.95±0.09 and 1.10±0.18 [×10−3 mm2/s]). Conclusions MT and diffusion-weighted magnetic resonance imaging sequences are promising for the staging of thrombus composition and could be useful in guiding medical intervention. PMID:23564561

  14. First-pass myocardial perfusion imaging with whole-heart coverage using L1-SPIRiT accelerated variable density spiral trajectories

    PubMed Central

    Yang, Yang; Kramer, Christopher M.; Shaw, Peter W.; Meyer, Craig H.; Salerno, Michael

    2015-01-01

    Purpose To design and evaluate 2D L1-SPIRiT accelerated spiral pulse sequences for first-pass myocardial perfusion imaging with whole heart coverage capable of measuring 8 slices at 2 mm in-plane resolution at heart rates up to 125 beats per minute (BPM). Methods Combinations of 5 different spiral trajectories and 4 k-t sampling patterns were retrospectively simulated in 25 fully sampled datasets and reconstructed with L1-SPIRiT to determine the best combination of parameters. Two candidate sequences were prospectively evaluated in 34 human subjects to assess in-vivo performance. Results A dual density broad transition spiral trajectory with either angularly uniform or golden angle in time k-t sampling pattern had the largest structural similarity (SSIM) and smallest root mean square error (RMSE) from the retrospective simulation, and the L1-SPIRiT reconstruction had well-preserved temporal dynamics. In vivo data demonstrated that both of the sampling patterns could produce high quality perfusion images with whole-heart coverage. Conclusion First-pass myocardial perfusion imaging using accelerated spirals with optimized trajectory and k-t sampling pattern can produce high quality 2D-perfusion images with wholeheart coverage at the heart rates up to 125 BPM. PMID:26538511

  15. k-t SENSE-accelerated Myocardial Perfusion MR Imaging at 3.0 Tesla - comparison with 1.5 Tesla

    PubMed Central

    Plein, Sven; Schwitter, Juerg; Suerder, Daniel; Greenwood, John P.; Boesiger, Peter; Kozerke, Sebastian

    2008-01-01

    Purpose To determine the feasibility and diagnostic accuracy of high spatial resolution myocardial perfusion MR at 3.0 Tesla using k-space and time domain undersampling with sensitivity encoding (k-t SENSE). Materials and Methods The study was reviewed and approved by the local ethic review board. k-t SENSE perfusion MR was performed at 1.5 Tesla and 3.0 Tesla (saturation recovery gradient echo pulse sequence, repetition time/echo time 3.0ms/1.0ms, flip angle 15°, 5x k-t SENSE acceleration, spatial resolution 1.3×1.3×10mm3). Fourteen volunteers were studied at rest and 37 patients during adenosine stress. In volunteers, comparison was also made with standard-resolution (2.5×2.5×10mm3) 2x SENSE perfusion MR at 3.0 Tesla. Image quality, artifact scores, signal-to-noise ratios (SNR) and contrast-enhancement ratios (CER) were derived. In patients, diagnostic accuracy of visual analysis to detect >50% diameter stenosis on quantitative coronary angiography was determined by receiver-operator-characteristics (ROC). Results In volunteers, image quality and artifact scores were similar for 3.0 Tesla and 1.5 Tesla, while SNR was higher (11.6 vs. 5.6) and CER lower (1.1 vs. 1.5, p=0.012) at 3.0 Tesla. Compared with standard-resolution perfusion MR, image quality was higher for k-t SENSE (3.6 vs. 3.1, p=0.04), endocardial dark rim artifacts were reduced (artifact thickness 1.6mm vs. 2.4mm, p<0.001) and CER similar. In patients, area under the ROC curve for detection of coronary stenosis was 0.89 and 0.80, p=0.21 for 3.0 Tesla and 1.5 Tesla, respectively. Conclusions k-t SENSE accelerated high-resolution perfusion MR at 3.0 Tesla is feasible with similar artifacts and diagnostic accuracy as at 1.5 Tesla. Compared with standard-resolution perfusion MR, image quality is improved and artifacts are reduced. PMID:18936311

  16. Proton Density Fat Fraction Measurements at 1.5- and 3-T Hepatic MR Imaging: Same-Day Agreement among Readers and across Two Imager Manufacturers.

    PubMed

    Serai, Suraj D; Dillman, Jonathan R; Trout, Andrew T

    2017-07-01

    Purpose To determine the agreement of proton density fat fraction (PDFF) measurements obtained with hepatic magnetic resonance (MR) imaging among readers, imager manufacturers, and field strengths. Materials and Methods This HIPAA-compliant study was approved by the institutional review board. After providing informed consent, 24 adult volunteers underwent imaging with one 1.5-T MR unit (Ingenia; Philips Healthcare, Best, the Netherlands) and two different 3.0-T units (750 W [GE Healthcare, Waukesha, Wis] and Ingenia) on the same day to estimate hepatic PDFF. A single-breath-hold multipoint Dixon-based acquisition was performed with commercially available pulse sequences provided by the MR imager manufacturers (mDIXON Quant [Philips Healthcare], IDEAL IQ [GE Healthcare]). Five readers placed one large region of interest, inclusive of as much liver parenchyma as possible in the right lobe while avoiding large vessels, on imager-generated parametric maps to measure hepatic PDFF. Two-way single-measure intraclass correlation coefficients (ICCs) were used to assess interreader agreement and agreement across the three imaging platforms. Results Excellent interreader agreement for hepatic PDFF measurements was obtained with mDIXON Quant and the Philips 1.5-T unit (ICC, 0.995; 95% confidence interval [CI]: 0.991, 0.998), mDIXON Quant and the Philips 3.0-T unit (ICC, 0.992; 95% CI: 0.986, 0.996), and IDEAL IQ and the GE 3.0-T unit (ICC, 0.966; 95% CI: 0.939, 0.984). Individual reader ICCs for hepatic PDFF measurements across all three imager manufacturer-field strength combinations also showed excellent interimager agreement, ranging from 0.914 to 0.954. Conclusion Estimation of PDFF with hepatic MR imaging by using multipoint Dixon techniques is highly reproducible across readers, field strengths, and imaging platforms. © RSNA, 2017.

  17. T2-weighted high-intensity signals in the basal ganglia as an interesting image finding in Unverricht-Lundborg disease.

    PubMed

    Korja, Miikka; Ferlazzo, Edoardo; Soilu-Hänninen, Merja; Magaudda, Adriana; Marttila, Reijo; Genton, Pierre; Parkkola, Riitta

    2010-01-01

    We conducted a search for white matter changes (WMCs) in 13 Unverricht-Lundborg disease patients and compared the prevalence of WMCs in these patients to age-matched long-term epileptics and healthy controls. ULD patients had significantly more T2-weighted high-intensity signals on MRI than control subjects, due to the increased prevalence of these signals in the basal ganglia. Interestingly, ULD patients with the basal ganglia changes were overweight. Basal ganglia T2-weighted high-intensity signals are novel findings in ULD. 2009 Elsevier B.V. All rights reserved.

  18. Comparison of gadolinium-EOB-DTPA-enhanced and diffusion-weighted liver MRI for detection of small hepatic metastases.

    PubMed

    Shimada, Kotaro; Isoda, Hiroyoshi; Hirokawa, Yuusuke; Arizono, Shigeki; Shibata, Toshiya; Togashi, Kaori

    2010-11-01

    To compare the accuracy of gadolinium ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI with that of diffusion-weighted MRI (DWI) in the detection of small hepatic metastases (2 cm or smaller). Forty-five patients underwent abdominal MRI at 3 T, including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), heavily T2WI (HASTE), DWI with a b-value of 500 s/mm(2) and contrast-enhanced MRI with Gd-EOB-DTPA. Two groups were assigned and compared: group A (T1WI, T2WI, HASTE and contrast-enhanced study with Gd-EOB-DTPA), and group B (T1WI, T2WI, HASTE and DWI). Two observers independently interpreted the images obtained in a random order. For all hepatic metastases, the diagnostic performance using each imaging set was evaluated by receiver-operating characteristic (ROC) curve analysis. A total of 51 hepatic metastases were confirmed. The area under the ROC curve (Az) of group A was larger than that of group B, and the difference in the mean Az values between the two image sets was statistically significant, whereas, there were three metastases that lay near thin vessels or among multiple cysts and were better visualised in group B than in group A. Gd-EOB-DTPA-enhanced MRI showed higher accuracy in the detection of small metastases than DWI.

  19. Texture analysis of T1-w and T2-w MR images allows a quantitative evaluation of radiation-induced changes of internal obturator muscles after radiotherapy for prostate cancer.

    PubMed

    Scalco, Elisa; Rancati, Tiziana; Pirovano, Ileana; Mastropietro, Alfonso; Palorini, Federica; Cicchetti, Alessandro; Messina, Antonella; Avuzzi, Barbara; Valdagni, Riccardo; Rizzo, Giovanna

    2018-04-01

    To investigate the potential of texture analysis applied on T2-w and postcontrast T1-w images acquired before radiotherapy for prostate cancer (PCa) and 12 months after its completion in quantitatively characterizing local radiation effect on the muscular component of internal obturators, as organs potentially involved in urinary toxicity. T2-w and postcontrast T1-w MR images were acquired at 1.5 T before treatment (MRI1) and at 12 months of follow-up (MRI2) in 13 patients treated with radiotherapy for PCa. Right and left internal obturator muscle contours were manually delineated upon MRI1 and then automatically propagated on MRI2 by an elastic registration method. Planning CT images were coregistered to both MRIs and dose maps were deformed accordingly. A high-dose region receiving >55 Gy and a low-dose region receiving <55 Gy were identified in each muscle volume. Eighteen textural features were extracted from each region of interest and differences between MRI1 and MRI2 were evaluated. A signal increase was highlighted in both T2-w and T1-w images in the portion of the obturators near the prostate, i.e., in the region receiving medium-high doses. A change in the spatial organization was identified, as an increase in homogeneity and a decrease in contrast and complexity, compatible with an inflammatory status. In particular, the region receiving medium-high doses presented more significant or, at least, stronger differences. Texture analysis applied on T1-w and T2-w MR images has demonstrated its ability in quantitative evaluating radiation-induced changes in obturator muscles after PCa radiotherapy. © 2018 American Association of Physicists in Medicine.

  20. Detection of benign prostatic hyperplasia nodules in T2W MR images using fuzzy decision forest

    NASA Astrophysics Data System (ADS)

    Lay, Nathan; Freeman, Sabrina; Turkbey, Baris; Summers, Ronald M.

    2016-03-01

    Prostate cancer is the second leading cause of cancer-related death in men MRI has proven useful for detecting prostate cancer, and CAD may further improve detection. One source of false positives in prostate computer-aided diagnosis (CAD) is the presence of benign prostatic hyperplasia (BPH) nodules. These nodules have a distinct appearance with a pseudo-capsule on T2 weighted MR images but can also resemble cancerous lesions in other sequences such as the ADC or high B-value images. Describing their appearance with hand-crafted heuristics (features) that also exclude the appearance of cancerous lesions is challenging. This work develops a method based on fuzzy decision forests to automatically learn discriminative features for the purpose of BPH nodule detection in T2 weighted images for the purpose of improving prostate CAD systems.

  1. Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system.

    PubMed

    Zhang, Xiaoyong; Qiu, Bensheng; Wei, Zijun; Yan, Fei; Shi, Caiyun; Su, Shi; Liu, Xin; Ji, Jim X; Xie, Guoxi

    2017-01-01

    To develop and assess a three-dimensional (3D) self-gated technique for the evaluation of myocardial infarction (MI) in mouse model without the use of external electrocardiogram (ECG) trigger and respiratory motion sensor on a 3T clinical MR system. A 3D T1-weighted GRE sequence with stack-of-stars sampling trajectories was developed and performed on six mice with MIs that were injected with a gadolinium-based contrast agent at a 3T clinical MR system. Respiratory and cardiac self-gating signals were derived from the Cartesian mapping of the k-space center along the partition encoding direction by bandpass filtering in image domain. The data were then realigned according to the predetermined self-gating signals for the following image reconstruction. In order to accelerate the data acquisition, image reconstruction was based on compressed sensing (CS) theory by exploiting temporal sparsity of the reconstructed images. In addition, images were also reconstructed from the same realigned data by conventional regridding method for demonstrating the advantageous of the proposed reconstruction method. Furthermore, the accuracy of detecting MI by the proposed method was assessed using histological analysis as the standard reference. Linear regression and Bland-Altman analysis were used to assess the agreement between the proposed method and the histological analysis. Compared to the conventional regridding method, the proposed CS method reconstructed images with much less streaking artifact, as well as a better contrast-to-noise ratio (CNR) between the blood and myocardium (4.1 ± 2.1 vs. 2.9 ± 1.1, p = 0.031). Linear regression and Bland-Altman analysis demonstrated that excellent correlation was obtained between infarct sizes derived from the proposed method and histology analysis. A 3D T1-weighted self-gating technique for mouse cardiac imaging was developed, which has potential for accurately evaluating MIs in mice at 3T clinical MR system without the use of external

  2. Detection of hepatocellular carcinoma in transgenic mice by Gd-DTPA- and rhodamine 123-conjugated human serum albumin nanoparticles in T1 magnetic resonance imaging.

    PubMed

    Watcharin, Waralee; Schmithals, Christian; Pleli, Thomas; Köberle, Verena; Korkusuz, Hüdayi; Hübner, Frank; Waidmann, Oliver; Zeuzem, Stefan; Korf, Horst-Werner; Terfort, Andreas; Gelperina, Svetlana; Vogl, Thomas J; Kreuter, Jörg; Piiper, Albrecht

    2015-02-10

    Nanoparticle (NP)-based contrast agents that enable high resolution anatomic T1-weighted magnetic resonance imaging (MRI) offer the prospect of improving differential diagnosis of liver tumors such as hepatocellular carcinoma (HCC). In the present study, we investigated the possibility of employing novel non-toxic human serum albumin nanoparticles conjugated with Gd-DTPA and rhodamine 123 (Gd-Rho-HSA-NPs) for the detection of HCC by T1-weighted MRI. In addition, the influence of surface coating of the NPs with poloxamine 908, which alters the absorptive behavior of NPs and changes their distribution between the liver and tumor was examined. MRI of transgenic mice with endogenously formed HCCs following intravenous injection of Gd-Rho-HSA-NPs revealed a strong negative contrast of the tumors. Contrasting of the HCCs by NP-enhanced MRI required less Gd as compared to gadolinium-ethoxybenzyl-diethylenetriaminepentaacetic acid-enhanced MRI, which currently provides the most sensitive detection of HCC in patients. Immunohistochemical analyses revealed that the Gd-Rho-HSA-NPs were localized to macrophages, which were - similar to HCC in patients - fewer in number in HCC as compared to the liver tissue, which is in agreement with the negative contrasting of HCC in Gd-Rho-HSA-NP-enhanced MRI. Poloxamine-coated NPs showed lower accumulation in the tumor macrophages and caused a longer lasting enhancement of the MRI signal. These data indicate that Gd-Rho-HSA-NPs enable sensitive detection of HCC by T1-weighted MRI in mice with endogenous HCC through their uptake by macrophages. Poloxamine coating of the NPs delayed the tumor localization of the NPs. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Improve Image Quality of Transversal Relaxation Time PROPELLER and FLAIR on Magnetic Resonance Imaging

    NASA Astrophysics Data System (ADS)

    Rauf, N.; Alam, D. Y.; Jamaluddin, M.; Samad, B. A.

    2018-03-01

    The Magnetic Resonance Imaging (MRI) is a medical imaging technique that uses the interaction between the magnetic field and the nuclear spins. MRI can be used to show disparity of pathology by transversal relaxation time (T2) weighted images. Some techniques for producing T2-weighted images are Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction (PROPELLER) and Fluid Attenuated Inversion Recovery (FLAIR). A comparison of T2 PROPELLER and T2 FLAIR parameters in MRI image has been conducted. And improve Image Quality the image by using RadiAnt DICOM Viewer and ENVI software with method of image segmentation and Region of Interest (ROI). Brain images were randomly selected. The result of research showed that Time Repetition (TR) and Time Echo (TE) values in all types of images were not influenced by age. T2 FLAIR images had longer TR value (9000 ms), meanwhile T2 PROPELLER images had longer TE value (100.75 - 102.1 ms). Furthermore, areas with low and medium signal intensity appeared clearer by using T2 PROPELLER images (average coefficients of variation for low and medium signal intensity were 0.0431 and 0.0705, respectively). As for areas with high signal intensity appeared clearer by using T2 FLAIR images (average coefficient of variation was 0.0637).

  4. Susceptibility weighted imaging of cartilage canals in porcine epiphyseal growth cartilage ex vivo and in vivo.

    PubMed

    Nissi, Mikko J; Toth, Ferenc; Zhang, Jinjin; Schmitter, Sebastian; Benson, Michael; Carlson, Cathy S; Ellermann, Jutta M

    2014-06-01

    High-resolution visualization of cartilage canals has been restricted to histological methods and contrast-enhanced imaging. In this study, the feasibility of non-contrast-enhanced susceptibility weighted imaging (SWI) for visualization of the cartilage canals was investigated ex vivo at 9.4 T, further explored at 7 and 3 T and demonstrated in vivo at 7 T, using a porcine animal model. SWI scans of specimens of distal femur and humerus from 1 to 8 week-old piglets were conducted at 9.4 T using 3D-GRE sequence and SWI post-processing. The stifle joints of a 2-week old piglet were scanned ex vivo at 7 and 3 T. Finally, the same sites of a 3-week-old piglet were scanned, in vivo, at 7 T under general anesthesia using the vendor-provided sequences. High-contrast visualization of the cartilage canals was obtained ex vivo, especially at higher field strengths; the results were confirmed histologically. In vivo feasibility was demonstrated at 7 T and comparison of ex vivo scans at 3 and 7 T indicated feasibility of using SWI at 3 T. High-resolution 3D visualization of cartilage canals was demonstrated using SWI. This demonstration of fully noninvasive visualization opens new avenues to explore skeletal maturation and the role of vascular supply for diseases such as osteochondrosis. Copyright © 2013 Wiley Periodicals, Inc.

  5. Comparison of qualitative and quantitative analysis of T2-weighted MRI scans in chronic-progressive multiple sclerosis

    NASA Astrophysics Data System (ADS)

    Adams, Hans-Peter; Wagner, Simone; Koziol, James A.

    1998-06-01

    Magnetic resonance imaging (MRI) is routinely used for the diagnosis of multiple sclerosis (MS), and for objective assessment of the extent of disease as a marker of treatment efficacy in MS clinical trials. The purpose of this study is to compare the evaluation of T2-weighted MRI scans in MS patients using a semi-automated quantitative technique with an independent assessment by a neurologist. Baseline, 6- month, and 12-month T2-weighted MRI scans from 41 chronic progressive MS patients were examined. The lesion volume ranged from 0.50 to 51.56 cm2 (mean: 8.08 cm2). Reproducibility of the quantitative technique was assessed by the re-evaluation of a random subset of 20 scans, the coefficient of variation of the replicate determinations was 8.2%. The reproducibility of the neurologist evaluations was assessed by the re-evaluation of a random subset of 10 patients. The rank correlation between the results of the two methods was 0.097, which did not significantly differ from zero. Disease-related activity in T2-weighted MRI scans is a multi-dimensional construct, and is not adequately summarized solely by determination of lesion volume. In this setting, image analysis software should not only support storage and retrieval as sets of pixels, but should also support links to an anatomical dictionary.

  6. Effect of intravenous gadolinium-DTPA on diffusion-weighted imaging for prostate lesions and normal tissue at 3.0-Tesla magnetic resonance imaging.

    PubMed

    Liu, Xiaohang; Zhou, Liangping; Peng, Weijun; Qian, Min

    2011-06-01

    Post-contrast diffusion-weighted imaging (DWI) is occasionally necessary when the results of the pre-contrast DWI differ from that of the dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), however, the effects of contrast material on DWI image and apparent diffusion coefficient (ADC) values have not been fully examined. To assess whether the administration of gadolinium-DTPA (Gd-DTPA) significantly affects the DWI of prostate lesions or normal tissue at the 3.0 Tesla magnetic resonance imaging (3.0 T MRI). Fifty-one patients with 52 prostate lesions, including 32 prostate cancer (25 in the peripheral zone [PZ] and seven that could not be confidently located) and 20 benign lesions (11 in PZ and nine in central grand [CG]), underwent echo-planar imaging (EPI)-DWI with b values of 0, 1000 s/mm(2) before and after administration of Gd-DTPA at 3.0 T MRI. Regions of interest (ROI) were drawn in all lesions, 42 normal PZ, 44 CG tissue and air to calculate the signal-to-noise ratio (SNR) and ADC values of lesions and normal tissue, and contrast-to-noise ratio (CNR) of lesions for pre- and post-contrast images. Statistical differences between pre- and post-contrast data were assessed by use of a paired t test. No significant differences between pre- and post-contrast images were found in the CNR of lesions and SNR of all the tissue except CG, which showed a statistically significant decline (9.6%, p < 0.0001) in SNR after contrast relative to the pre-contrast images. The post-contrast ADC values were statistically significantly lower than pre-contrast for prostate cancer (0.80 ± 0.11 mm(2)/s Vs 0.89 ± 0.12 mm(2)/s, p < 0.0001) and benign lesions (1.14 ± 0.30 mm(2)/s vs. 1.2 ± 0.29 mm(2)/s, p < 0.0001). No significant differences were detected for normal tissue. The administration of Gd-DTPA can slightly affect the DWI image quality of the prostate and reduce the ADC value of lesions at 3.0T MRI. Applications of post-contrast DWI require caution in

  7. Child dermoid cyst mimicking a craniopharyngioma: the benefit of MRI T2-weighted diffusion sequence.

    PubMed

    Amelot, Aymeric; Borha, Alin; Calmon, Raphael; Barbet, Patrick; Puget, Stephanie

    2018-02-01

    Brain dermoid cysts are very rare lesions. Although benign, these cysts may be associated with devastating complications due to mass effect or meningitis. The discovery of completely asymptomatic dermoid cysts in the pediatric population is exceedingly rare. Despite the advances in imaging modalities, it sometimes remains difficult to exclude the differential diagnosis of craniopharyngioma. We describe a 12-year-old boy addressed for suspicion of craniopharyngioma diagnosed by decreased visual acuity, bitemporal hemianopia and a CT scan showing a large hypodense suprasellar lesion with intralesional calcifications. Despite the unusual localization and size of this lesion, the absence of dermal sinus commonly found, and before visualizing a hyperintense mass on MRI-diffusion, the diagnosis of craniopharyngioma was ruled out in favor of a dermoid cyst. Radical excision was performed. In the suprasellar area, craniopharyngioma and dermoid cyst may have very similar radiological aspects: low density masses on CT scan and a hyperintense signal on T1-weighted MRI sequences with a variable signal on T2-weighted sequences. Hitherto, only two cases in literature have described suprasellar dermoid cyst. Their initial diagnosis was facilitated by the presence of a dermal sinus.

  8. Correlation study between facet joint cartilage and intervertebral discs in early lumbar vertebral degeneration using T2, T2* and T1ρ mapping

    PubMed Central

    Zhang, Yi; Hu, Jianzhong; Duan, Chunyue; Hu, Ping; Lu, Hongbin; Peng, Xianjing

    2017-01-01

    Recent advancements in magnetic resonance imaging have allowed for the early detection of biochemical changes in intervertebral discs and articular cartilage. Here, we assessed the feasibility of axial T2, T2* and T1ρ mapping of the lumbar facet joints (LFJs) to determine correlations between cartilage and intervertebral discs (IVDs) in early lumbar vertebral degeneration. We recruited 22 volunteers and examined 202 LFJs and 101 IVDs with morphological (sagittal and axial FSE T2-weighted imaging) and axial biochemical (T2, T2* and T1ρ mapping) sequences using a 3.0T MRI scanner. IVDs were graded using the Pfirrmann system. Mapping values of LFJs were recorded according to the degeneration grades of IVDs at the same level. The feasibility of T2, T2* and T1ρ in IVDs and LFJs were analyzed by comparing these mapping values across subjects with different rates of degeneration using Kruskal-Wallis tests. A Pearson’s correlation analysis was used to compare T2, T2* and T1ρ values of discs and LFJs. We found excellent reproducibility in the T2, T2* and T1ρ values for the nucleus pulposus (NP), anterior and posterior annulus fibrosus (PAF), and LFJ cartilage (intraclass correlation coefficients 0.806–0.955). T2, T2* and T1ρ mapping (all P<0.01) had good Pfirrmann grade performances in the NP with IVD degeneration. LFJ T2* values were significantly different between grades I and IV (PL = 0.032, PR = 0.026), as were T1ρ values between grades II and III (PL = 0.002, PR = 0.006) and grades III and IV (PL = 0.006, PR = 0.001). Correlations were moderately negative for T1ρ values between LFJ cartilage and NP (rL = −0.574, rR = −0.551), and between LFJ cartilage and PAF (rL = −0.551, rR = −0.499). T1ρ values of LFJ cartilage was weakly correlated with T2 (r = 0.007) and T2* (r = −0.158) values. Overall, we show that axial T1ρ effectively assesses early LFJ cartilage degeneration. Using T1ρ analysis, we propose a link between LFJ degeneration and IVD NP or

  9. Mn(II) based T1 and T2 potential MRI contrast agent appended with tryptamine: Recognition moiety for Aβ-plaques.

    PubMed

    Rastogi, Neeraj; Tyagi, Nidhi; Singh, Ovender; Hemanth Kumar, B S; Singh, Udai P; Ghosh, Kaushik; Roy, Raja

    2017-12-01

    We report the synthesis and characterization of manganese(II) complexes having pentadentate ligands L 1 (2,6-bis(1-(2-phenyl-2-(pyridin-2-yl)hydrazono)ethyl)pyridine), L 2 (methyl 2,6-bis((E)-1-(2-phenyl-2-(pyridin-2yl)hydrazono)ethyl)isonicotinate), L 3 (N-(2-(1H-indol-3-yl)ethyl)-2,6-bis((E)-1-(2-phenyl-2-(pyridin2yl)hydrazono)ethyl)isonicotiamide) and their application as dual contrast agents for simultaneous T 1 and T 2 weighted magnetic resonance imaging. Single crystal analysis of all the complexes [Mn II L 1 , Mn II L 2 and Mn II L 3 ] confirm the formation of novel seven-coordinate manganese complexes with an inner sphere water and perchlorate ion. The Magnetic Resonance Imaging (MRI) contrast agent [MnL 2 ] was further modified by incorporating tryptamine as a binding moiety specific to Amyloid Beta-fibrils (Aβ-fibrils) in Alzhiemer's disease (AD) and it's in vitro evaluation for specific binding with Aβ-fibrils indicated as a bio-marker of AD. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Magnetic resonance imaging metallic artifact of commonly encountered surgical implants and foreign material.

    PubMed

    Sutherland-Smith, James; Tilley, Brenda

    2012-01-01

    Magnetic resonance imaging (MRI) artifacts secondary to metallic implants and foreign bodies are well described. Herein, we provide quantitative data from veterinary implants including total hip arthroplasty implants, cranial cruciate repair implants, surgical screws, a skin staple, ligation clips, an identification microchip, ameroid constrictor, and potential foreign bodies including air gun and BB projectiles and a sewing needle. The objects were scanned in a gelatin phantom with plastic grid using standardized T2-weighted turbo-spin echo (TSE), T1-weighted spin echo, and T2*-weighted gradient recalled echo (GRE) image acquisitions at 1.5 T. Maximum linear dimensions and areas of signal voiding and grid distortion were calculated using a DICOM workstation for each sequence and object. Artifact severity was similar between the T2-weighted TSE and T1-weighted images, while the T2*-weighted images were most susceptible to artifact. Metal type influenced artifact size with the largest artifacts arising from steel objects followed by surgical stainless steel, titanium, and lead. For animals with metallic surgical implants or foreign bodies, the quantification of the artifact size will help guide clinicians on the viability of MRI. © 2012 Veterinary Radiology & Ultrasound.

  11. Imaging cellularity in benign and malignant peripheral nerve sheath tumors: Utility of the "target sign" by diffusion weighted imaging.

    PubMed

    Ahlawat, Shivani; Fayad, Laura M

    2018-05-01

    To determine the utility of "target sign" on diffusion weighted imaging (DWI) and apparent diffusion coefficient (ADC) mapping for peripheral nerve sheath tumor (PNST) characterization. This IRB-approved, HIPAA-compliant study retrospectively reviewed the MR imaging (comprised of T2- FS, DWI (b-values 50, 400, 800 s/mm 2 and ADC mapping), and static contrast-enhanced (CE) T1-W imaging) of 42 patients (mean age: 40 years (range 8-68 years), 48% (20/42) females) with 15 malignant PNSTs (MPNSTs) and 33 benign PNSTs (BPNSTs). MPNSTs were histologically confirmed while BPNSTs were histologically-proven or with stable clinical and imaging appearance for at least 12 months. Two radiologists assessed imaging characteristics (size, signal intensity, heterogeneity, perilesional edema or enhancement) and the presence or absence of "target sign," on each sequence. A "target sign" was defined as a biphasic pattern of peripheral hyperintensity and homogeneous central hypointensity. Descriptive statistics are reported. Cohen's κ statistic or interclass correlation coefficient (ICC) were used to evaluate interobserver agreement between two observers. Univariate and multiple logistic regression analysis were performed to identify MRI features with predictive values. MPNSTs were larger than BPNSTs (6.3 ± 2.5 cm vs 3.5 ± -2.1 cm, p = 0.0002), had perilesional edema (87%(13/15) vs 18%(6/33), p < 0.0001), heterogeneous enhancement (71%(10/14) vs 13%(4/31), p = 0.0001) and perilesional enhancement (79%(11/14) vs 18%(6/31), p = 0.0001), respectively. The "target sign" was present in: 24%(8/33) BPNSTs vs 0/15 MPNST on T2-FS (p = 0.26); 39%(13/33) BPNSTs vs 20%(3/15) MPNST on DWI using b-value = 50 s/mm 2 (p = 0.5); 55%(18/33) BPNSTs vs 6%(1/15) MPNST on DWI using b-value = 400 s/mm 2 (p = 0.002); 48%(16/33) BPNSTs vs 6%(1/15) MPNST on DWI using b-value = 800 s/mm 2 (p = 0.005) and 64%(21/33) benign vs 0/15 MPNST on ADC

  12. Comparison of 7T and 3T MRI in patients with moyamoya disease.

    PubMed

    Oh, Byeong Ho; Moon, Hyeong Cheol; Baek, Hyeon Man; Lee, Youn Joo; Kim, Sang Woo; Jeon, Young Jai; Lee, Gun Seok; Kim, Hong Rae; Choi, Jai Ho; Min, Kyung Soo; Lee, Mou Seop; Kim, Young Gyu; Kim, Dong Ho; Kim, Won Seop; Park, Young Seok

    2017-04-01

    Magnetic resonance imaging and magnetic resonance angiography (MRI/MRA) are widely used for evaluating the moyamoya disease (MMD). This study compared the diagnostic accuracy of 7Tesla (T) and 3T MRI/MRA in MMD. In this case control study, 12 patients [median age: 34years; range (10-66years)] with MMD and 12 healthy controls [median age: 25years; range (22-59years)] underwent both 7T and 3T MRI/MRA. To evaluate the accuracy of MRI/MRA in MMD, five criteria were compared between imaging systems of 7T and 3T: Suzuki grading system, internal carotid artery (ICA) diameter, ivy sign, flow void of the basal ganglia on T2-weighted images, and high signal intensity areas of the basal ganglia on time-of-flight (TOF) source images. No difference was observed between 7T and 3T MRI/MRA in Suzuki stage, ICA diameter, and ivy sign score; while, 7T MRI/MRA showed a higher detection rate in the flow void on T2-weighted images and TOF source images (p<0.001). Receiver operating characteristic curves of both T2 and TOF criteria showed that 7T MRI/MRA had higher sensitivity and specificity than 3T MRI/MRA. Our findings indicate that 7T MRI/MRA is superior to 3T MRI/MRA for the diagnosis of MMD in point of detecting the flow void in basal ganglia by T2-weighted and TOF images. Copyright © 2016. Published by Elsevier Inc.

  13. Assessment of cerebral microbleeds by susceptibility-weighted imaging in Alzheimer's disease patients: A neuroimaging biomarker of the disease.

    PubMed

    Sparacia, Gianvincenzo; Agnello, Francesco; La Tona, Giuseppe; Iaia, Alberto; Midiri, Federico; Sparacia, Benedetta

    2017-08-01

    Purpose The objective of this study was to correlate the presence and distribution of cerebral microbleeds in Alzheimer's disease patients with cerebrospinal fluid biomarkers (amyloid-beta and phosphorylated tau 181 protein levels) and cognitive decline by using susceptibility-weighted imaging magnetic resonance sequences at 1.5 T. Material and methods Fifty-four consecutive Alzheimer's disease patients underwent brain magnetic resonance imaging at 1.5 T to assess the presence and distribution of cerebral microbleeds on susceptibility-weighted imaging images. The images were analyzed in consensus by two neuroradiologists, each with at least 10 years' experience. Dementia severity was assessed with the Mini-Mental State Examination score. A multiple regression analysis was performed to assess the associations between the number and location of cerebral microbleed lesions with the age, sex, duration of the disease, cerebrospinal fluid amyloid-beta and phosphorylated tau 181 protein levels, and cognitive functions. Results A total of 296 microbleeds were observed in 54 patients; 38 patients (70.4%) had lobar distribution, 13 patients (24.1%) had non-lobar distribution, and the remaining three patients (5.6%) had mixed distribution, demonstrating that Alzheimer's disease patients present mainly a lobar distribution of cerebral microbleeds. The age and the duration of the disease were correlated with the number of lobar cerebral microbleeds ( P < 0.001). Cerebrospinal fluid amyloid-beta, phosphorylated tau 181 protein levels, and cognitive decline were correlated with the number of lobar cerebral microbleeds in Alzheimer's disease patients ( P < 0.001). Conclusion Lobar distribution of cerebral microbleeds is associated with Alzheimer's disease and the number of lobar cerebral microbleeds directly correlates with cerebrospinal fluid amyloid-beta and phosphorylated tau 181 protein levels and with the cognitive decline of Alzheimer's disease patients.

  14. Diffusion-weighted magnetic resonance imaging in monitoring rectal cancer response to neoadjuvant chemoradiotherapy.

    PubMed

    Barbaro, Brunella; Vitale, Renata; Valentini, Vincenzo; Illuminati, Sonia; Vecchio, Fabio M; Rizzo, Gianluca; Gambacorta, Maria Antonietta; Coco, Claudio; Crucitti, Antonio; Persiani, Roberto; Sofo, Luigi; Bonomo, Lorenzo

    2012-06-01

    To prospectively monitor the response in patients with locally advanced nonmucinous rectal cancer after chemoradiotherapy (CRT) using diffusion-weighted magnetic resonance imaging. The histopathologic finding was the reference standard. The institutional review board approved the present study. A total of 62 patients (43 men and 19 women; mean age, 64 years; range, 28-83) provided informed consent. T(2)- and diffusion-weighted magnetic resonance imaging scans (b value, 0 and 1,000 mm(2)/s) were acquired before, during (mean 12 days), and 6-8 weeks after CRT. We compared the median apparent diffusion coefficients (ADCs) between responders and nonresponders and examined the associations with the Mandard tumor regression grade (TRG). The postoperative nodal status (ypN) was evaluated. The Mann-Whitney/Wilcoxon two-sample test was used to evaluate the relationships among the pretherapy ADCs, extramural vascular invasion, early percentage of increases in ADCs, and preoperative ADCs. Low pretreatment ADCs (<1.0 × 10(-3)mm(2)/s) were correlated with TRG 4 scores (p = .0011) and associated to extramural vascular invasion with ypN+ (85.7% positive predictive value for ypN+). During treatment, the mean percentage of increase in tumor ADC was significantly greater in the responders than in the nonresponders (p < .0001) and a >23% ADC increase had a 96.3% negative predictive value for TRG 4. In 9 of 16 complete responders, CRT-related tumor downsizing prevented ADC evaluations. The preoperative ADCs were significantly different (p = .0012) between the patients with and without downstaging (preoperative ADC ≥1.4 × 10(-3)mm(2)/s showed a positive and negative predictive value of 78.9% and 61.8%, respectively, for response assessment). The TRG 1 and TRG 2-4 groups were not significantly different. Diffusion-weighted magnetic resonance imaging seems to be a promising tool for monitoring the response to CRT. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Diffusion-Weighted Magnetic Resonance Imaging in Monitoring Rectal Cancer Response to Neoadjuvant Chemoradiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barbaro, Brunella, E-mail: bbarbaro@rm.unicatt.it; Vitale, Renata; Valentini, Vincenzo

    2012-06-01

    Purpose: To prospectively monitor the response in patients with locally advanced nonmucinous rectal cancer after chemoradiotherapy (CRT) using diffusion-weighted magnetic resonance imaging. The histopathologic finding was the reference standard. Methods and Materials: The institutional review board approved the present study. A total of 62 patients (43 men and 19 women; mean age, 64 years; range, 28-83) provided informed consent. T{sub 2}- and diffusion-weighted magnetic resonance imaging scans (b value, 0 and 1,000 mm{sup 2}/s) were acquired before, during (mean 12 days), and 6-8 weeks after CRT. We compared the median apparent diffusion coefficients (ADCs) between responders and nonresponders and examinedmore » the associations with the Mandard tumor regression grade (TRG). The postoperative nodal status (ypN) was evaluated. The Mann-Whitney/Wilcoxon two-sample test was used to evaluate the relationships among the pretherapy ADCs, extramural vascular invasion, early percentage of increases in ADCs, and preoperative ADCs. Results: Low pretreatment ADCs (<1.0 Multiplication-Sign 10{sup -3}mm{sup 2}/s) were correlated with TRG 4 scores (p = .0011) and associated to extramural vascular invasion with ypN+ (85.7% positive predictive value for ypN+). During treatment, the mean percentage of increase in tumor ADC was significantly greater in the responders than in the nonresponders (p < .0001) and a >23% ADC increase had a 96.3% negative predictive value for TRG 4. In 9 of 16 complete responders, CRT-related tumor downsizing prevented ADC evaluations. The preoperative ADCs were significantly different (p = .0012) between the patients with and without downstaging (preoperative ADC {>=}1.4 Multiplication-Sign 10{sup -3}mm{sup 2}/s showed a positive and negative predictive value of 78.9% and 61.8%, respectively, for response assessment). The TRG 1 and TRG 2-4 groups were not significantly different. Conclusion: Diffusion-weighted magnetic resonance imaging seems to be a

  16. Novel Imaging Contrast Methods for Hyperpolarized 13 C Magnetic Resonance Imaging

    NASA Astrophysics Data System (ADS)

    Reed, Galen Durant

    Magnetic resonance imaging using hyperpolarized 13C-labeled small molecules has emerged as an extremely powerful tool for the in vivo monitoring of perfusion and metabolism. This work presents methods for improved imaging, parameter mapping, and image contrast generation for in vivo hyperpolarized 13C MRI. Angiography using hyperpolarized urea was greatly improved with a highly T2-weighted acquisition in combination with 15N labeling of the urea amide groups. This is due to the fact that the T2 of [13C]urea is strongly limited by the scalar coupling to the neighboring quadrupolar 14N. The long in vivo T2 values of [13C, 15N2]urea were utilized for sub-millimeter projection angiography using a contrast agent that could be safely injected in concentrations of 10-100 mM while still tolerated in patients with renal insufficiency. This study also presented the first method for in vivo T2 mapping of hyperpolarized 13C compounds. The in vivo T2 of urea was short in the blood and long within the kidneys. This persistent signal component was isolated to the renal filtrate, thus enabling for the first time direct detection of an imaging contrast agent undergoing glomerular filtration. While highly T2-weighted acquisitions select for molecules with short rotational correlation times, high diffusion weighting selects for those with the long translational correlation times. A specialized spin-echo EPI sequence was developed in order to generate highly diffusion-weighted hyperpolarized 13C images on a clinical MRI system operating within clinical peak- RF and gradient amplitude constraints. Low power adiabatic spin echo pulses were developed in order to generate a sufficiently large refocused bandwidth while maintaining low nominal power. This diffusion weighted acquisition gave enhanced tumor contrast-to-noise ratio when imaging [1-13C]lactate after infusion of [1-13C]pyruvate. Finally, the first in-man hyperpolarized 13C MRI clinical trial is discussed.

  17. Detection and staging of chondromalacia patellae: relative efficacies of conventional MR imaging, MR arthrography, and CT arthrography.

    PubMed

    Gagliardi, J A; Chung, E M; Chandnani, V P; Kesling, K L; Christensen, K P; Null, R N; Radvany, M G; Hansen, M F

    1994-09-01

    Chondromalacia patellae is a condition characterized by softening, fraying, and ulceration of patellar articular cartilage. We compare the sensitivity, specificity, and accuracy of conventional MR imaging, MR arthrography, and CT arthrography in detecting and staging this abnormality. Twenty-seven patients with pain in the anterior part of the knee were prospectively examined with MR imaging, including T1-weighted (650/16), proton density-weighted (2000/20), T2-weighted (2000/80), and spoiled two-dimensional gradient-recalled acquisition in the steady state (SPGR/)/35 degrees (51/10) with fat saturation pulse sequences. All were also examined with T1-weighted MR imaging after intraarticular injection of dilute gadopentetate dimeglumine and with double-contrast CT arthrography. Each imaging technique was evaluated independently by two observers, who reached a consensus interpretation. The signal characteristics of cartilage on MR images and contour abnormalities noted with all imaging techniques were evaluated and graded according to a modification of the classification of Shahriaree. Twenty-six of the 54 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity, and accuracy of each imaging technique in the diagnosis of each stage of chondromalacia patellae were determined and compared by using the McNemar two-tailed analysis. Arthroscopy showed that 28 facets were normal. Grade 1 chondromalacia patellae was diagnosed only with MR and CT arthrography in two (29%) of seven facets. Intermediate (grade 2 or 3) chondromalacia patellae was detected in two (13%) of 15 facets with T1-weighted and SPGR MR imaging, in three (20%) of 15 facets with proton density-weighted MR imaging, in seven (47%) of 15 facets with T2-weighted MR imaging, in 11 (73%) of 15 facets with CT arthrography, and in 12 (80%) of 15 facets with MR arthrography. Grade 4 was detected in three (75%) of four facets with T1-, proton

  18. First-pass myocardial perfusion imaging with whole-heart coverage using L1-SPIRiT accelerated variable density spiral trajectories.

    PubMed

    Yang, Yang; Kramer, Christopher M; Shaw, Peter W; Meyer, Craig H; Salerno, Michael

    2016-11-01

    To design and evaluate two-dimensional (2D) L1-SPIRiT accelerated spiral pulse sequences for first-pass myocardial perfusion imaging with whole heart coverage capable of measuring eight slices at 2 mm in-plane resolution at heart rates up to 125 beats per minute (BPM). Combinations of five different spiral trajectories and four k-t sampling patterns were retrospectively simulated in 25 fully sampled datasets and reconstructed with L1-SPIRiT to determine the best combination of parameters. Two candidate sequences were prospectively evaluated in 34 human subjects to assess in vivo performance. A dual density broad transition spiral trajectory with either angularly uniform or golden angle in time k-t sampling pattern had the largest structural similarity and smallest root mean square error from the retrospective simulation, and the L1-SPIRiT reconstruction had well-preserved temporal dynamics. In vivo data demonstrated that both of the sampling patterns could produce high quality perfusion images with whole-heart coverage. First-pass myocardial perfusion imaging using accelerated spirals with optimized trajectory and k-t sampling pattern can produce high quality 2D perfusion images with whole-heart coverage at the heart rates up to 125 BPM. Magn Reson Med 76:1375-1387, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.

  19. Diffusion-Weighted Magnetic Resonance Imaging Early After Chemoradiotherapy to Monitor Treatment Response in Head-and-Neck Squamous Cell Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vandecaveye, Vincent, E-mail: Vincent.Vandecaveye@uzleuven.be; Dirix, Piet; De Keyzer, Frederik

    2012-03-01

    Purpose: To evaluate diffusion-weighted imaging (DWI) for assessment of treatment response in head and neck squamous cell carcinoma (HNSCC) three weeks after the end of chemoradiotherapy (CRT). Methods and Materials: Twenty-nine patients with HNSCC underwent magnetic resonance imaging (MRI) prior to and 3 weeks after CRT, including T{sub 2}-weighted and pre- and postcontrast T{sub 1}-weighted sequences and an echo-planar DWI sequence with six b values (0 to 1,000 s/mm{sup 2}), from which the apparent diffusion coefficient (ADC) was calculated. ADC changes 3 weeks posttreatment compared to baseline ( Increment ADC) between responding and nonresponding primary lesions and adenopathies were correlatedmore » with 2 years locoregional control and compared with a Mann-Whitney test. In a blinded manner, the Increment ADC was compared to conventional MRI 3 weeks post-CRT and the routinely implemented CT, on average 3 months post-CRT, which used size-related and morphological criteria. Positive and negative predictive values (PPV and NPV, respectively) were compared between the Increment ADC and anatomical imaging. Results: The Increment ADC of lesions with later tumor recurrence was significantly lower than lesions with complete remission for both primary lesions (-2.3% {+-} 0.3% vs. 80% {+-} 41%; p < 0.0001) and adenopathies (19.9% {+-} 32% vs. 63% {+-} 36%; p = 0.003). The Increment ADC showed a PPV of 89% and an NPV of 100% for primary lesions and a PPV of 70% and an NPV of 96% for adenopathies per neck side. DWI improved PPV and NPV compared to anatomical imaging. Conclusion: DWI with the Increment ADC 3 weeks after concluding CRT for HNSCC allows for early assessment of treatment response.« less

  20. 7T MRI-Histologic Correlation Study of Low Specific Absorption Rate T2-Weighted GRASE Sequences in the Detection of White Matter Involvement in Multiple Sclerosis.

    PubMed

    Bagnato, Francesca; Hametner, Simon; Pennell, David; Dortch, Richard; Dula, Adrienne N; Pawate, Siddharama; Smith, Seth A; Lassmann, Hans; Gore, John C; Welch, Edward B

    2015-01-01

    The high value of the specific absorption rate (SAR) of radio-frequency (RF) energy arising from the series of RF refocusing pulses in T2-weighted (T2-w) turbo spin echo (TSE) MRI hampers its clinical application at 7.0 Tesla (7T). T2-w gradient and spin echo (GRASE) uses the speed from gradient refocusing in combination with the chemical-shift/static magnetic field (B0) inhomogeneity insensitivity from spin-echo refocusing to acquire T2-w images with a limited number of refocusing RF pulses, thus reducing SAR. To investigate whether low SAR T2-w GRASE could replace T2-w TSE in detecting white matter (WM) disease in MS patients imaged at 7T. The .7 mm3 isotropic T2-w TSE and T2-w GRASE images with variable echo times (TEs) and echo planar imaging (EPI) factors were obtained on a 7T scanner from postmortem samples of MS brains. These samples were derived from brains of 3 female MS patients. WM lesions (WM-Ls) and normal-appearing WM (NAWM) signal intensity, WM-Ls/NAWM contrast-to-noise ratio (CNR) and MRI/myelin staining sections comparisons were obtained. GRASE sequences with EPI factor/TE = 3/50 and 3/75 ms were comparable to the SE technique for measures of CNR in WM-Ls and NAWM and for detection of WM-Ls. In all sequences, however, identification of areas with remyelination, Wallerian degeneration, and gray matter demyelination, as depicted by myelin staining, was not possible. T2-w GRASE images may replace T2-w TSE for clinical use. However, even at 7T, both sequences fail in detecting and characterizing MS disease beyond visible WM-Ls. Copyright © 2015 by the American Society of Neuroimaging.

  1. Local T1-T2 distribution measurements in porous media

    NASA Astrophysics Data System (ADS)

    Vashaee, S.; Li, M.; Newling, B.; MacMillan, B.; Marica, F.; Kwak, H. T.; Gao, J.; Al-harbi, A. M.; Balcom, B. J.

    2018-02-01

    A novel slice-selective T1-T2 measurement is proposed to measure spatially resolved T1-T2 distributions. An adiabatic inversion pulse is employed for slice-selection. The slice-selective pulse is able to select a quasi-rectangular slice, on the order of 1 mm, at an arbitrary position within the sample. The method does not employ conventional selective excitation in which selective excitation is often accomplished by rotation of the longitudinal magnetization in the slice of interest into the transverse plane, but rather a subtraction based on CPMG data acquired with and without adiabatic inversion slice selection. T1 weighting is introduced during recovery from the inversion associated with slice selection. The local T1-T2 distributions measured are of similar quality to bulk T1-T2 measurements. The new method can be employed to characterize oil-water mixtures and other fluids in porous media. The method is beneficial when a coarse spatial distribution of the components is of interest.

  2. Detection of liver metastasis: is diffusion-weighted imaging needed in Gd-EOB-DTPA-enhanced MR imaging for evaluation of colorectal liver metastases?

    PubMed

    Tajima, Taku; Akahane, Masaaki; Takao, Hidemasa; Akai, Hiroyuki; Kiryu, Shigeru; Imamura, Hiroshi; Watanabe, Yasushi; Kokudo, Norihiro; Ohtomo, Kuni

    2012-10-01

    We compared diagnostic ability for detecting hepatic metastases between gadolinium ethoxy benzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) on a 1.5-T system, and determined whether DWI is necessary in Gd-EOB-DTPA-enhanced MRI for diagnosing colorectal liver metastases. We assessed 29 consecutive prospectively enrolled patients with suspected metachronous colorectal liver metastases; all patients underwent surgery and had preoperative Gd-EOB-DTPA-enhanced MRI. Overall detection rate, sensitivity for detecting metastases and benign lesions, positive predictive value, and diagnostic accuracy (Az value) were compared among three image sets [unenhanced MRI (DWI set), Gd-EOB-DTPA-enhanced MRI excluding DWI (EOB set), and combined set]. Gd-EOB-DTPA-enhanced MRI yielded better overall detection rate (77.8-79.0 %) and sensitivity (87.1-89.4 %) for detecting metastases than the DWI set (55.9 % and 64.7 %, respectively) for one observer (P < 0.001). No statistically significant difference was seen between the EOB and combined sets, although several metastases were newly detected on additional DWI. Gd-EOB-DTPA-enhanced MRI yielded a better overall detection rate and higher sensitivity for detecting metastases compared with unenhanced MRI. Additional DWI may be able to reduce oversight of lesions in Gd-EOB-DTPA-enhanced 1.5-T MRI for detecting colorectal liver metastases.

  3. Advantages of high b-value diffusion-weighted imaging to diagnose pseudo-responses in patients with recurrent glioma after bevacizumab treatment.

    PubMed

    Yamasaki, Fumiyuki; Kurisu, Kaoru; Aoki, Tomokazu; Yamanaka, Masami; Kajiwara, Yoshinori; Watanabe, Yosuke; Takayasu, Takeshi; Akiyama, Yuji; Sugiyama, Kazuhiko

    2012-10-01

    The diagnosis of pseudo-responses after bevacizumab treatment is difficult. Because diffusion-weighted imaging (DWI) is associated with cell density, it may facilitate the differentiation between true- and pseudo-responses. Furthermore, as high b-value DWI is even more sensitive to diffusion, it has been reported to be diagnostically useful in various clinical settings. Between September 2008 and May 2011, 10 patients (5 males, 5 females; age range 6-65 years) with recurrent glioma were treated with bevacizumab. All underwent pre- and post-treatment MRI including T2- or FLAIR imaging, post-gadolinium contrast T1-weighted imaging, and DWI with b-1000 and b-4000. Response rates were evaluated by MacDonald- and by response assessment in neuro-oncology working group (RANO) criteria. We also assessed the response rate by calculating the size of high intensity areas using high b-value diffusion-weighted criteria. Prognostic factors were evaluated using Kaplan-Meier survival curves (log-rank test). It was easier to identify pseudo-responses with RANO- than MacDonald criteria, however the reduction of edema by bevacizumab rendered the early diagnosis of tumor progression difficult by RANO criteria. In some patients with recurrent glioma treated with bevacizumab, high b-value diffusion-weighted criteria did, while MacDonald- and RANO criteria did not identify pseudo-responses at an early point after the start of therapy. High b-value DWI reflects cell density more accurately than regular b-value DWI. Our findings suggest that in patients with recurrent glioma, high b-value diffusion-weighted criteria are useful for the differentiation between pseudo- and true responses to treatment with bevacizumab. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. 3D Cones Acquisition of Human Extremity Imaging Using a 1.5T Superconducting Magnet and an Unshielded Gradient Coil Set.

    PubMed

    Setoi, Ayana; Kose, Katsumi

    2018-05-16

    We developed ultrashort echo-time (UTE) imaging sequences with 3D Cones trajectories for a home-built compact MRI system using a 1.5T superconducting magnet and an unshielded gradient coil set. We achieved less than 7 min imaging time and obtained clear in vivo images of a human forearm with a TE of 0.4 ms. We concluded that UTE imaging using 3D Cones acquisition was successfully implemented in our 1.5T MRI system.

  5. High-b-value diffusion-weighted MR imaging for pretreatment prediction and early monitoring of tumor response to therapy in mice.

    PubMed

    Roth, Yiftach; Tichler, Thomas; Kostenich, Genady; Ruiz-Cabello, Jesus; Maier, Stephan E; Cohen, Jack S; Orenstein, Arie; Mardor, Yael

    2004-09-01

    To evaluate the use of diffusion-weighted magnetic resonance (MR) imaging with standard and high b values for pretreatment prediction and early detection of tumor response to various antineoplastic therapies in an animal model. Mice bearing C26 colon carcinoma tumors were treated with doxorubicin (n = 25) and with aminolevulinic acid-based photodynamic therapy (n = 23). Fourteen mice served as controls. Conventional T2-weighted fast spin-echo and diffusion-weighted MR images were acquired once before therapy and at 6, 24, and 48 hours after treatment. Pretreatment and early (1-2 days) posttreatment water diffusion parameters were calculated and compared with later changes in tumor volumes measured on conventional MR images by using the Pearson correlation test. In chemotherapy-treated tumors, a significant correlation (P <.002, r = 0.6) was observed between diffusion parameters that reflected tumor viability, measured prior to treatment, and changes in tumor volumes after therapy. This correlation implies that tumors with high pretreatment viability will respond better to chemotherapy than more necrotic tumors. In tumors treated with photodynamic therapy, no such correlation was found. Changes observed in water diffusion 1-2 days after treatment significantly correlated with later tumor growth rate for both therapies (P <.002, r = 0.54 for photodynamic therapy; P <.0003, r = 0.61 for chemotherapy). High-b-value diffusion-weighted MR imaging has potential use for the early detection of response to therapy and for predicting treatment outcome prior to initiation of chemotherapy. Copyright RSNA, 2004

  6. Grading of Gliomas by Using Monoexponential, Biexponential, and Stretched Exponential Diffusion-weighted MR Imaging and Diffusion Kurtosis MR Imaging

    PubMed Central

    Bai, Yan; Lin, Yusong; Tian, Jie; Shi, Dapeng; Cheng, Jingliang; Haacke, E. Mark; Hong, Xiaohua; Ma, Bo; Zhou, Jinyuan

    2016-01-01

    Purpose To quantitatively compare the potential of various diffusion parameters obtained from monoexponential, biexponential, and stretched exponential diffusion-weighted imaging models and diffusion kurtosis imaging in the grading of gliomas. Materials and Methods This study was approved by the local ethics committee, and written informed consent was obtained from all subjects. Both diffusion-weighted imaging and diffusion kurtosis imaging were performed in 69 patients with pathologically proven gliomas by using a 3-T magnetic resonance (MR) imaging unit. An isotropic apparent diffusion coefficient (ADC), true ADC, pseudo-ADC, and perfusion fraction were calculated from diffusion-weighted images by using a biexponential model. A water molecular diffusion heterogeneity index and distributed diffusion coefficient were calculated from diffusion-weighted images by using a stretched exponential model. Mean diffusivity, fractional anisotropy, and mean kurtosis were calculated from diffusion kurtosis images. All values were compared between high-grade and low-grade gliomas by using a Mann-Whitney U test. Receiver operating characteristic and Spearman rank correlation analysis were used for statistical evaluations. Results ADC, true ADC, perfusion fraction, water molecular diffusion heterogeneity index, distributed diffusion coefficient, and mean diffusivity values were significantly lower in high-grade gliomas than in low-grade gliomas (U = 109, 56, 129, 6, 206, and 229, respectively; P < .05). Pseudo-ADC and mean kurtosis values were significantly higher in high-grade gliomas than in low-grade gliomas (U = 98 and 8, respectively; P < .05). Both water molecular diffusion heterogeneity index (area under the receiver operating characteristic curve [AUC] = 0.993) and mean kurtosis (AUC = 0.991) had significantly greater AUC values than ADC (AUC = 0.866), mean diffusivity (AUC = 0.722), and fractional anisotropy (AUC = 0.500) in the differentiation of low-grade and high

  7. Focal liver lesions segmentation and classification in nonenhanced T2-weighted MRI.

    PubMed

    Gatos, Ilias; Tsantis, Stavros; Karamesini, Maria; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Hazle, John D; Kagadis, George C

    2017-07-01

    To automatically segment and classify focal liver lesions (FLLs) on nonenhanced T2-weighted magnetic resonance imaging (MRI) scans using a computer-aided diagnosis (CAD) algorithm. 71 FLLs (30 benign lesions, 19 hepatocellular carcinomas, and 22 metastases) on T2-weighted MRI scans were delineated by the proposed CAD scheme. The FLL segmentation procedure involved wavelet multiscale analysis to extract accurate edge information and mean intensity values for consecutive edges computed using horizontal and vertical analysis that were fed into the subsequent fuzzy C-means algorithm for final FLL border extraction. Texture information for each extracted lesion was derived using 42 first- and second-order textural features from grayscale value histogram, co-occurrence, and run-length matrices. Twelve morphological features were also extracted to capture any shape differentiation between classes. Feature selection was performed with stepwise multilinear regression analysis that led to a reduced feature subset. A multiclass Probabilistic Neural Network (PNN) classifier was then designed and used for lesion classification. PNN model evaluation was performed using the leave-one-out (LOO) method and receiver operating characteristic (ROC) curve analysis. The mean overlap between the automatically segmented FLLs and the manual segmentations performed by radiologists was 0.91 ± 0.12. The highest classification accuracies in the PNN model for the benign, hepatocellular carcinoma, and metastatic FLLs were 94.1%, 91.4%, and 94.1%, respectively, with sensitivity/specificity values of 90%/97.3%, 89.5%/92.2%, and 90.9%/95.6% respectively. The overall classification accuracy for the proposed system was 90.1%. Our diagnostic system using sophisticated FLL segmentation and classification algorithms is a powerful tool for routine clinical MRI-based liver evaluation and can be a supplement to contrast-enhanced MRI to prevent unnecessary invasive procedures. © 2017 American

  8. Semiautomated spleen volumetry with diffusion-weighted MR imaging.

    PubMed

    Lee, Jeongjin; Kim, Kyoung Won; Lee, Ho; Lee, So Jung; Choi, Sanghyun; Jeong, Woo Kyoung; Kye, Heewon; Song, Gi-Won; Hwang, Shin; Lee, Sung-Gyu

    2012-07-01

    In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-MR images. Manual spleen volumetry was performed on DW-MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW-MR (r = 0.99; P < 0.0001; mean percentage absolute difference, 1.43 ± 0.94) and CT (r = 0.99; P < 0.0001; 1.76 ± 1.07). Mean total processing time for semiautomated volumetry was significantly shorter compared to that of manual volumetry with DW-MR (P < 0.0001) and CT (P < 0.0001). In conclusion, semiautomated spleen volumetry with DW-MR images can be performed rapidly and accurately when compared with standard manual volumetry. Copyright © 2011 Wiley Periodicals, Inc.

  9. Parametric techniques for characterizing myocardial tissue by magnetic resonance imaging (part 1): T1 mapping.

    PubMed

    Perea Palazón, R J; Ortiz Pérez, J T; Prat González, S; de Caralt Robira, T M; Cibeira López, M T; Solé Arqués, M

    2016-01-01

    The development of myocardial fibrosis is a common process in the appearance of ventricular dysfunction in many heart diseases. Magnetic resonance imaging makes it possible to accurately evaluate the structure and function of the heart, and its role in the macroscopic characterization of myocardial fibrosis by late enhancement techniques has been widely validated clinically. Recent studies have demonstrated that T1-mapping techniques can quantify diffuse myocardial fibrosis and the expansion of the myocardial extracellular space in absolute terms. However, further studies are necessary to validate the usefulness of this technique in the early detection of tissue remodeling at a time when implementing early treatment would improve a patient's prognosis. This article reviews the state of the art for T1 mapping of the myocardium, its clinical applications, and its limitations. Copyright © 2016 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  10. Imaging Human Brain Perfusion with Inhaled Hyperpolarized 129Xe MR Imaging.

    PubMed

    Rao, Madhwesha R; Stewart, Neil J; Griffiths, Paul D; Norquay, Graham; Wild, Jim M

    2018-02-01

    Purpose To evaluate the feasibility of directly imaging perfusion of human brain tissue by using magnetic resonance (MR) imaging with inhaled hyperpolarized xenon 129 ( 129 Xe). Materials and Methods In vivo imaging with 129 Xe was performed in three healthy participants. The combination of a high-yield spin-exchange optical pumping 129 Xe polarizer, custom-built radiofrequency coils, and an optimized gradient-echo MR imaging protocol was used to achieve signal sensitivity sufficient to directly image hyperpolarized 129 Xe dissolved in the human brain. Conventional T1-weighted proton (hydrogen 1 [ 1 H]) images and perfusion images by using arterial spin labeling were obtained for comparison. Results Images of 129 Xe uptake were obtained with a signal-to-noise ratio of 31 ± 9 and demonstrated structural similarities to the gray matter distribution on conventional T1-weighted 1 H images and to perfusion images from arterial spin labeling. Conclusion Hyperpolarized 129 Xe MR imaging is an injection-free means of imaging the perfusion of cerebral tissue. The proposed method images the uptake of inhaled xenon gas to the extravascular brain tissue compartment across the intact blood-brain barrier. This level of sensitivity is not readily available with contemporary MR imaging methods. © RSNA, 2017.

  11. Role of apparent diffusion coefficients with diffusion-weighted magnetic resonance imaging in differentiating between benign and malignant bone tumors.

    PubMed

    Wang, Tingting; Wu, Xiangru; Cui, Yanfen; Chu, Caiting; Ren, Gang; Li, Wenhua

    2014-11-29

    Benign and malignant bone tumors can present similar imaging features. This study aims to evaluate the significance of apparent diffusion coefficients (ADC) in differentiating between benign and malignant bone tumors. A total of 187 patients with 198 bone masses underwent diffusion-weighted (DW) magnetic resonance (MR) imaging. The ADC values in the solid components of the bone masses were assessed. Statistical differences between the mean ADC values in the different tumor types were determined by Student's t-test. Histological analysis showed that 84/198 (42.4%) of the bone masses were benign and 114/198 (57.6%) were malignant. There was a significant difference between the mean ADC values in the benign and malignant bone lesions (P<0.05). However, no significant difference was found in the mean ADC value between non-ossifying fibromas, osteofibrous dysplasia, and malignant bone tumors. When an ADC cutoff value≥1.10×10(-3) mm2/s was applied, malignant bone lesions were excluded with a sensitivity of 89.7%, a specificity of 84.5%, a positive predictive value of 82.6%, and a negative predictive value of 95.3%. The combination of DW imaging with ADC quantification and T2-weighted signal characteristics of the solid components in lesions can facilitate differentiation between benign and malignant bone tumors.

  12. Design of universal parallel-transmit refocusing kT -point pulses and application to 3D T2 -weighted imaging at 7T.

    PubMed

    Gras, Vincent; Mauconduit, Franck; Vignaud, Alexandre; Amadon, Alexis; Le Bihan, Denis; Stöcker, Tony; Boulant, Nicolas

    2018-07-01

    T 2 -weighted sequences are particularly sensitive to the radiofrequency (RF) field inhomogeneity problem at ultra-high-field because of the errors accumulated by the imperfections of the train of refocusing pulses. As parallel transmission (pTx) has proved particularly useful to counteract RF heterogeneities, universal pulses were recently demonstrated to save precious time and computational efforts by skipping B 1 calibration and online RF pulse tailoring. Here, we report a universal RF pulse design for non-selective refocusing pulses to mitigate the RF inhomogeneity problem at 7T in turbo spin-echo sequences with variable flip angles. Average Hamiltonian theory was used to synthetize a single non-selective refocusing pulse with pTx while optimizing its scaling properties in the presence of static field offsets. The design was performed under explicit power and specific absorption rate constraints on a database of 10 subjects using a 8Tx-32Rx commercial coil at 7T. To validate the proposed design, the RF pulses were tested in simulation and applied in vivo on 5 additional test subjects. The root-mean-square rotation angle error (RA-NRMSE) evaluation and experimental data demonstrated great improvement with the proposed universal pulses (RA-NRMSE ∼8%) compared to the standard circularly polarized mode of excitation (RA-NRMSE ∼26%). This work further completes the spectrum of 3D universal pulses to mitigate RF field inhomogeneity throughout all 3D MRI sequences without any pTx calibration. The approach returns a single pulse that can be scaled to match the desired flip angle train, thereby increasing the modularity of the proposed plug and play approach. Magn Reson Med 80:53-65, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. High-resolution 3D-constructive interference in steady-state MR imaging and 3D time-of-flight MR angiography in neurovascular compression: a comparison between 3T and 1.5T.

    PubMed

    Garcia, M; Naraghi, R; Zumbrunn, T; Rösch, J; Hastreiter, P; Dörfler, A

    2012-08-01

    High-resolution MR imaging is useful for diagnosis and preoperative planning in patients with NVC. Because high-field MR imaging promises higher SNR and resolution, the aim of this study was to determine the value of high-resolution 3D-CISS and 3D-TOF MRA at 3T compared with 1.5T in patients with NVC. Forty-seven patients with NVC, trigeminal neuralgia, hemifacial spasm, and glossopharyngeal neuralgia were examined at 1.5T and 3T, including high-resolution 3D-CISS and 3D-TOF MRA sequences. Delineation of anatomic structures, overall image quality, severity of artifacts, visibility of NVC, and assessment of the SNR and CNR were compared between field strengths. SNR and CNR were significantly higher at 3T (P < .001). Significantly better anatomic conspicuity, including delineation of CNs, nerve branches, and assessment of small vessels, was obtained at 3T (P < .02). Severity of artifacts was significantly lower at 3T (P < .001). Consequently, overall image quality was significantly higher at 3T. NVC was significantly better delineated at 3T (P < .001). Six patients in whom NVC was not with certainty identifiable at 1.5T were correctly diagnosed at 3T. Patients with NVC may benefit from the higher resolution and greater sensitivity of 3T for preoperative assessment of NVC, and 3T may be of particular value when 1.5T is equivocal.

  14. Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system

    PubMed Central

    Li, Ye; Pang, Yong; Vigneron, Daniel; Glenn, Orit; Xu, Duan; Zhang, Xiaoliang

    2011-01-01

    Fetal MRI on 1.5T clinical scanner has been increasingly becoming a powerful imaging tool for studying fetal brain abnormalities in vivo. Due to limited availability of dedicated fetal phased arrays, commercial torso or cardiac phased arrays are routinely used for fetal scans, which are unable to provide optimized SNR and parallel imaging performance with a small number coil elements, and insufficient coverage and filling factor. This poses a demand for the investigation and development of dedicated and efficient radiofrequency (RF) hardware to improve fetal imaging. In this work, an investigational approach to simulate the performance of multichannel flexible phased arrays is proposed to find a better solution to fetal MR imaging. A 32 channel fetal array is presented to increase coil sensitivity, coverage and parallel imaging performance. The electromagnetic field distribution of each element of the fetal array is numerically simulated by using finite-difference time-domain (FDTD) method. The array performance, including B1 coverage, parallel reconstructed images and artifact power, is then theoretically calculated and compared with the torso array. Study results show that the proposed array is capable of increasing B1 field strength as well as sensitivity homogeneity in the entire area of uterus. This would ensure high quality imaging regardless of the location of the fetus in the uterus. In addition, the paralleling imaging performance of the proposed fetal array is validated by using artifact power comparison with torso array. These results demonstrate the feasibility of the 32 channel flexible array for fetal MR imaging at 1.5T. PMID:22408747

  15. Ultra high spatial and temporal resolution breast imaging at 7T.

    PubMed

    van de Bank, B L; Voogt, I J; Italiaander, M; Stehouwer, B L; Boer, V O; Luijten, P R; Klomp, D W J

    2013-04-01

    There is a need to obtain higher specificity in the detection of breast lesions using MRI. To address this need, Dynamic Contrast-Enhanced (DCE) MRI has been combined with other structural and functional MRI techniques. Unfortunately, owing to time constraints structural images at ultra-high spatial resolution can generally not be obtained during contrast uptake, whereas the relatively low spatial resolution of functional imaging (e.g. diffusion and perfusion) limits the detection of small lesions. To be able to increase spatial as well as temporal resolution simultaneously, the sensitivity of MR detection needs to increase as well as the ability to effectively accelerate the acquisition. The required gain in signal-to-noise ratio (SNR) can be obtained at 7T, whereas acceleration can be obtained with high-density receiver coil arrays. In this case, morphological imaging can be merged with DCE-MRI, and other functional techniques can be obtained at higher spatial resolution, and with less distortion [e.g. Diffusion Weighted Imaging (DWI)]. To test the feasibility of this concept, we developed a unilateral breast coil for 7T. It comprises a volume optimized dual-channel transmit coil combined with a 30-channel receive array coil. The high density of small coil elements enabled efficient acceleration in any direction to acquire ultra high spatial resolution MRI of close to 0.6 mm isotropic detail within a temporal resolution of 69 s, high spatial resolution MRI of 1.5 mm isotropic within an ultra high temporal resolution of 6.7 s and low distortion DWI at 7T, all validated in phantoms, healthy volunteers and a patient with a lesion in the right breast classified as Breast Imaging Reporting and Data System (BI-RADS) IV. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Diffusion Weighted/Tensor Imaging, Functional MRI and Perfusion Weighted Imaging in Glioblastoma-Foundations and Future.

    PubMed

    Salama, Gayle R; Heier, Linda A; Patel, Praneil; Ramakrishna, Rohan; Magge, Rajiv; Tsiouris, Apostolos John

    2017-01-01

    In this article, we review the basics of diffusion tensor imaging and functional MRI, their current utility in preoperative neurosurgical mapping, and their limitations. We also discuss potential future applications, including implementation of resting state functional MRI. We then discuss perfusion and diffusion-weighted imaging and their application in advanced neuro-oncologic practice. We explain how these modalities can be helpful in guiding surgical biopsies and differentiating recurrent tumor from treatment related changes.

  17. Diffusion Weighted/Tensor Imaging, Functional MRI and Perfusion Weighted Imaging in Glioblastoma—Foundations and Future

    PubMed Central

    Salama, Gayle R.; Heier, Linda A.; Patel, Praneil; Ramakrishna, Rohan; Magge, Rajiv; Tsiouris, Apostolos John

    2018-01-01

    In this article, we review the basics of diffusion tensor imaging and functional MRI, their current utility in preoperative neurosurgical mapping, and their limitations. We also discuss potential future applications, including implementation of resting state functional MRI. We then discuss perfusion and diffusion-weighted imaging and their application in advanced neuro-oncologic practice. We explain how these modalities can be helpful in guiding surgical biopsies and differentiating recurrent tumor from treatment related changes. PMID:29403420

  18. Detection of cerebral amyloid angiopathy by 3-T magnetic resonance imaging and amyloid positron emission tomography in a patient with subcortical ischaemic vascular dementia.

    PubMed

    Kida, Hirotaka; Satoh, Masayuki; Ii, Yuichiro; Fukuyama, Hidenao; Maeda, Masayuki; Tomimoto, Hidekazu

    2017-01-01

    The patient was an 81-year-old man who had been treated for hypertension for several decades. In 2012, he developed gait disturbance and mild amnesia. One year later, his gait disturbance worsened, and he developed urinary incontinence. Conventional brain magnetic resonance imaging using T 2 -weighted images and fluid-attenuated inversion recovery showed multiple lacunar infarctions. These findings fulfilled the diagnostic criteria for subcortical ischaemic vascular dementia. However, susceptibility weighted imaging showed multiple lobar microbleeds in the bilateral occipitoparietal lobes, and double inversion recovery and 3-D fluid-attenuated inversion recovery images on 3-T magnetic resonance imaging revealed cortical microinfarctions in the left parietal-temporo-occipito region. Pittsburgh compound B-positron emission tomography revealed diffuse uptake in the cerebral cortex. Therefore, we diagnosed the patient with subcortical ischaemic vascular dementia associated with Alzheimer's disease. The use of the double inversion recovery and susceptibility weighted imaging on 3-T magnetic resonance imaging may be a supplemental strategy for diagnosing cerebral amyloid angiopathy, which is closely associated with Alzheimer's disease. © 2016 The Authors. Psychogeriatrics © 2016 Japanese Psychogeriatric Society.

  19. Image quality assessment of silent T2 PROPELLER sequence for brain imaging in infants.

    PubMed

    Kim, Hyun Gi; Choi, Jin Wook; Yoon, Soo Han; Lee, Sieun

    2018-02-01

    Infants are vulnerable to high acoustic noise. Acoustic noise generated by MR scanning can be reduced by a silent sequence. The purpose of this study is to compare the image quality of the conventional and silent T2 PROPELLER sequences for brain imaging in infants. A total of 36 scans were acquired from 24 infants using a 3 T MR scanner. Each patient underwent both conventional and silent T2 PROPELLER sequences. Acoustic noise level was measured. Quantitative and qualitative assessments were performed with the images taken with each sequence. The sound pressure level of the conventional T2 PROPELLER imaging sequence was 92.1 dB and that of the silent T2 PROPELLER imaging sequence was 73.3 dB (reduction of 20%). On quantitative assessment, the two sequences (conventional vs silent T2 PROPELLER) did not show significant difference in relative contrast (0.069 vs 0.068, p value = 0.536) and signal-to-noise ratio (75.4 vs 114.8, p value = 0.098). Qualitative assessment of overall image quality (p value = 0.572), grey-white differentiation (p value = 0.986), shunt-related artefact (p value > 0.999), motion artefact (p value = 0.801) and myelination degree in different brain regions (p values ≥ 0.092) did not show significant difference between the two sequences. The silent T2 PROPELLER sequence reduces acoustic noise and generated comparable image quality to that of the conventional sequence. Advances in knowledge: This is the first report to compare silent T2 PROPELLER images with that of conventional T2 PROPELLER images in children.

  20. T1 mapping combined with Gd-EOB-DTPA-enhanced magnetic resonance imaging in predicting the pathologic grading of hepatocellular carcinoma.

    PubMed

    Chen, C Y; Chen, J; Xia, C C; Huang, Z X; Song, B

    2017-01-01

    The aim of this study was to investigate the value of Gd-EOB-DTPA-enhanced MRI on hepatobiliary phase (HBP) imaging and T1 mapping sequence in the differentiation of hepatocellular carcinoma (HCC). A total of 45 patients with HCC who were to undergo a resection were enrolled in this study. Gd-EOB-DTPA-enhanced magnetic resonance examination was performed prior to resection. T1 mapping was performed before and 20 min after injection of Gd-EOB-DTPA. T1 values of the lesions were measured on pre-contrast (T1p) and during HBP (T1-HBP) on T1 maps. The signal intensity, the diameter and the margin of HCC lesions on HBP images were analyzed. The reduction in T1 value (T1d) and the reduction rate (ΔT1%) of T1 mapping between pre-contrast and HBP were calculated. The Edmondson-Steiner classification of each lesion was made after surgery. The SPSS software package was used for statistical analysis and the analysis of receiver operator characteristic (ROC) curve and area under the curve (AUC) were carried out by using MedCalc software package. Mean values of T1p and T1-HBP were 1935.4±730.8 ms and 1257.1±529.1 ms, respectively. T1p accuracy (AUC = 0.685, p = 0.037) in predicting pathological grading was similar to that of T1-HBP (AUC = 0.751, p = 0.005). A T1p of 1648.2 ms or greater had a sensitivity and specificity of 85.19% and 61.11%, respectively. A T1-HBP of 1006 ms or greater had a sensitivity and specificity of 81.84% and 61.11%, respectively. The number of HCCs with a non-smooth tumor margin was 20 (44.4%), and a non-smooth tumor margin correlated moderately with the Edmondson-Steiner grade (Spearman r = 0.491, p = 0.041). There was no significant correlation between T1d, ΔT1%, HCC signal intensity on HBP image and lesion diameter with pathologic grading. T1 mapping in pre-contrast and HBP of Gd-EOB-DTPA-enhanced MRI, a non-smooth tumor margin in the HBP of Gd-EOB-DTPA-enhanced MRI, are useful in predicting the pathologic grading of HCC.

  1. MR textural analysis on T2 FLAIR images for the prediction of true oligodendroglioma by the 2016 WHO genetic classification.

    PubMed

    Rui, Wenting; Ren, Yan; Wang, Yin; Gao, Xinyi; Xu, Xiao; Yao, Zhenwei

    2017-11-15

    The genetic status of 1p/19q is important for differentiating oligodendroglioma, isocitrate-dehydrogenase (IDH)-mutant, and 1p/19q-codeleted from diffuse astrocytoma, IDH-mutant according to the 2016 World Health Organization (WHO) criteria. To assess the value of magnetic resonance textural analysis (MRTA) on T 2 fluid-attenuated inversion recovery (FLAIR) images for making a genetically integrated diagnosis of true oligodendroglioma by WHO guidelines. Retrospective case control. In all, there were 54 patients with a histopathological diagnosis of diffuse glioma (grade II). All were tested for IDH and 1p/19q. 3.0T, including T 2 FLAIR sequence, axial T 1 -weighted, and T 2 -weighted sequence. MRTA on a representative tumor region of interest (ROI) was made on preoperative T 2 FLAIR images around the area that had the largest diameter of solid tumor using Omni Kinetics software. Differences between IDH-mutant and 1p/19q-codeleted and IDH-mutant and 1p/19q-intact gliomas were analyzed by the Mann-Whitney rank sum test. Receiver operating characteristic curves (ROC) were created to assess MRTA diagnostic performance. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated with a cutoff value according to the Youden Index. Comparisons demonstrated significant differences in kurtosis (P = 0.007), energy (0.008), entropy (0.008), mean deviation (MD) (<0.001), and high gray-level run emphasis (HGLRE) (0.002), cluster shade (0.025), and sum average (0.002). First-order features comprising entropy (area under the curve [AUC] = 0.718, sensitivity = 97.1%) and energy (0.719, 94.1%) had the highest sensitivity but lower specificity (both 45%). Second-order features such as HGLRE (AUC = 0.750, sensitivity = 73.5%, specificity = 80.0%) and sum average (0.751, 70.6%, 80.0%) had relatively higher specificity, and all had AUC >0.7. MD had the highest diagnostic performance, with AUC = 0

  2. CLOCK 3111 T/C SNP interacts with emotional eating behavior for weight-loss in a Mediterranean population

    USDA-ARS?s Scientific Manuscript database

    The goals of this research was (1) to analyze the role of emotional eating behavior on weight-loss progression during a 30-week weight-loss program in 1,272 individuals from a large Mediterranean population and (2) to test for interaction between CLOCK 3111 T/C SNP and emotional eating behavior on t...

  3. Comparison of qualitative and quantitative evaluation of diffusion-weighted MRI and chemical-shift imaging in the differentiation of benign and malignant vertebral body fractures.

    PubMed

    Geith, Tobias; Schmidt, Gerwin; Biffar, Andreas; Dietrich, Olaf; Dürr, Hans Roland; Reiser, Maximilian; Baur-Melnyk, Andrea

    2012-11-01

    The objective of our study was to compare the diagnostic value of qualitative diffusion-weighted imaging (DWI), quantitative DWI, and chemical-shift imaging in a single prospective cohort of patients with acute osteoporotic and malignant vertebral fractures. The study group was composed of patients with 26 osteoporotic vertebral fractures (18 women, eight men; mean age, 69 years; age range, 31 years 6 months to 86 years 2 months) and 20 malignant vertebral fractures (nine women, 11 men; mean age, 63.4 years; age range, 24 years 8 months to 86 years 4 months). T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW reverse fast imaging with steady-state free precession (PSIF) sequence at different delta values was evaluated qualitatively. A DW echo-planar imaging (EPI) sequence and a DW single-shot turbo spin-echo (TSE) sequence at different b values were evaluated qualitatively and quantitatively using the apparent diffusion coefficient. Opposed-phase sequences were used to assess signal intensity qualitatively. The signal loss between in- and opposed-phase images was determined quantitatively. Two-tailed Fisher exact test, Mann-Whitney test, and receiver operating characteristic analysis were performed. Sensitivities, specificities, and accuracies were determined. Qualitative DW-PSIF imaging (delta = 3 ms) showed the best performance for distinguishing between benign and malignant fractures (sensitivity, 100%; specificity, 88.5%; accuracy, 93.5%). Qualitative DW-EPI (b = 50 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.50]) and DW single-shot TSE imaging (b = 100 s/mm(2) [p = 1.00]; b = 250 s/mm(2) [p = 0.18]; b = 400 s/mm(2) [p = 0.18]; b = 600 s/mm(2) [p = 0.39]) did not indicate significant differences between benign and malignant fractures. DW-EPI using a b value of 500 s/mm(2) (p = 0.01) indicated significant differences between benign and malignant vertebral fractures. Quantitative DW-EPI (p = 0.09) and qualitative opposed-phase imaging (p = 0

  4. MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T

    PubMed Central

    Kuhn, Felix P; Spinner, Georg; Del Grande, Filippo; Wyss, Michael; Piccirelli, Marco; Erni, Stefan; Pfister, Pascal; Ho, Michael; Sah, Bert-Ram; Filli, Lukas; Ettlin, Dominik A; Gallo, Luigi M; Andreisek, Gustav

    2017-01-01

    Objectives: To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol. Methods: Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively. Results: TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed similar signal-to-noise ratio for both field strengths (mean ± SD; 7.0 T, 13.02 ± 3.92; 3.0 T, 14.02 ± 3.41; two-sample t-tests, p = 0.188). At 7.0 T, qualitative analysis yielded better visibility of all anatomical subregions of the temporomandibular disc (anterior band, intermediate zone and posterior band) than 3.0 T (Wilcoxon signed-rank tests, p < 0.05, corrected for multiple comparisons). Conclusions: MRI of the TMJ at 7.0 T using high-permittivity dielectric pads yields superior visibility of the temporomandibular disc compared with 3.0 T. PMID:27704872

  5. MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T.

    PubMed

    Kuhn, Felix P; Spinner, Georg; Del Grande, Filippo; Wyss, Michael; Piccirelli, Marco; Erni, Stefan; Pfister, Pascal; Ho, Michael; Sah, Bert-Ram; Filli, Lukas; Ettlin, Dominik A; Gallo, Luigi M; Andreisek, Gustav; Manoliu, Andrei

    2017-01-01

    To qualitatively and quantitatively compare MRI of the temporomandibular joint (TMJ) at 7.0 T using high-permittivity dielectric pads and 3.0 T using a clinical high-resolution protocol. Institutional review board-approved study with written informed consent. 12 asymptomatic volunteers were imaged at 7.0 and 3.0 T using 32-channel head coils. High-permittivity dielectric pads consisting of barium titanate in deuterated suspension were used for imaging at 7.0 T. Imaging protocol consisted of oblique sagittal proton density weighted turbo spin echo sequences. For quantitative analysis, pixelwise signal-to-noise ratio maps of the TMJ were calculated. For qualitative analysis, images were evaluated by two independent readers using 5-point Likert scales. Quantitative and qualitative results were compared using t-tests and Wilcoxon signed-rank tests, respectively. TMJ imaging at 7.0 T using high-permittivity dielectric pads was feasible in all volunteers. Quantitative analysis showed similar signal-to-noise ratio for both field strengths (mean ± SD; 7.0 T, 13.02 ± 3.92; 3.0 T, 14.02 ± 3.41; two-sample t-tests, p = 0.188). At 7.0 T, qualitative analysis yielded better visibility of all anatomical subregions of the temporomandibular disc (anterior band, intermediate zone and posterior band) than 3.0 T (Wilcoxon signed-rank tests, p < 0.05, corrected for multiple comparisons). MRI of the TMJ at 7.0 T using high-permittivity dielectric pads yields superior visibility of the temporomandibular disc compared with 3.0 T.

  6. Role of diffusion-weighted MRI in differentiation of hepatic abscesses from non-infected fluid collections.

    PubMed

    Schmid-Tannwald, C; Schmid-Tannwald, C M; Morelli, J N; Neumann, R; Reiser, M F; Nikolaou, K; Rist, C

    2014-07-01

    To evaluate the role of diffusion-weighted magnetic resonance imaging (DW-MRI) in the differentiation of hepatic abscesses from non-infected fluid collections. In this retrospective study, 22 hepatic abscesses and 27 non-infected hepatic fluid collections were examined in 27 patients who underwent abdominal MRI including DW-MRI. Two independent observers reviewed T2-weighted + DW-MRI and T2-weighted + contrast-enhanced T1-weighted (CET1W) images in two sessions. Detection rates and confidence levels were calculated and compared using McNemar's and Wilcoxon's signed rank tests, respectively. Apparent diffusion coefficient (ADC) values of abscesses and non-infected fluid collections were compared using the t-test. Receiver operating characteristic (ROC) curves were constructed. There was no statistically significant difference in the accuracy of detecting abscesses using T2-weighted + DW-MRI (both observers: 21/22, 95.5%) versus T2-weighted + CET1W images (observer 1: 21/22, 95.5%; observer 2: 22/22, 100%; p < 0.01). Mean ADC values were significantly lower with abscesses versus non-infected fluid collections (0.83 ± 0.24 versus 2.25 ± 0.61 × 10(-3) mm(2)/s; p < 0.001). With ROC analysis there was good discrimination of abscess from non-infected fluid collections at a threshold ADC value of 1.36 × 10(-3) mm(2)/s. DW-MRI allows qualitative and quantitative differentiation of abscesses from non-infected fluid collections in the liver. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. Magnetic single-walled carbon nanotubes as efficient drug delivery nanocarriers in breast cancer murine model: noninvasive monitoring using diffusion-weighted magnetic resonance imaging as sensitive imaging biomarker.

    PubMed

    Al Faraj, Achraf; Shaik, Abjal Pasha; Shaik, Asma Sultana

    2015-01-01

    Targeting doxorubicin (DOX) by means of single-walled carbon nanotube (SWCNT) nanocarriers may help improve the clinical utility of this highly active therapeutic agent. Active targeting of SWCNTs using tumor-specific antibody and magnetic attraction by tagging the nanotubes with iron oxide nanoparticles can potentially reduce the unnecessary side effects and provide enhanced theranostics. In the current study, the in vitro and in vivo efficacy of DOX-loaded SWCNTs as theranostic nanoprobes was evaluated in a murine breast cancer model. Iron-tagged SWCNTs conjugated with Endoglin/CD105 antibody with or without DOX were synthetized and extensively characterized. Their biocompatibility was assessed in vitro in luciferase (Luc2)-expressing 4T1 (4T1-Luc2) murine breast cancer cells using TiterTACS™ Colorimetric Apoptosis Detection Kit (apoptosis induction), poly (ADP-ribose) polymerase (marker for DNA damage), and thiobarbituric acid-reactive substances (oxidative stress generation) assays, and the efficacy of DOX-loaded SWCNTs was evaluated by measuring the radiance efficiency using bioluminescence imaging (BLI). Tumor progression and growth were monitored after 4T1-Luc2 cells inoculation using noninvasive BLI and magnetic resonance imaging (MRI) before and after subsequent injection of SWCNT complexes actively and magnetically targeted to tumor sites. Significant increases in apoptosis, DNA damage, and oxidative stress were induced by DOX-loaded SWCNTs. In addition, a tremendous decrease in bioluminescence was observed in a dose- and time-dependent manner. Noninvasive BLI and MRI revealed successful tumor growth and subsequent attenuation along with metastasis inhibition following DOX-loaded SWCNTs injection. Magnetic tagging of SWCNTs was found to produce significant discrepancies in apparent diffusion coefficient values providing a higher contrast to detect treatment-induced variations as noninvasive imaging biomarker. In addition, it allowed their sensitive

  8. The immediate effect of long-distance running on T2 and T2* relaxation times of articular cartilage of the knee in young healthy adults at 3.0 T MR imaging

    PubMed Central

    Welsch, Goetz H; Laqmani, Azien; Henes, Frank O; Kaul, Michael G; Schoen, Gerhard; Adam, Gerhard; Regier, Marc

    2016-01-01

    Objective: To quantitatively assess the immediate effect of long-distance running on T2 and T2* relaxation times of the articular cartilage of the knee at 3.0 T in young healthy adults. Methods: 30 healthy male adults (18–31 years) who perform sports at an amateur level underwent an initial MRI at 3.0 T with T2 weighted [16 echo times (TEs): 9.7–154.6 ms] and T2* weighted (24 TEs: 4.6–53.6 ms) relaxation measurements. Thereafter, all participants performed a 45-min run. After the run, all individuals were immediately re-examined. Data sets were post-processed using dedicated software (ImageJ; National Institute of Health, Bethesda, MD). 22 regions of interest were manually drawn in segmented areas of the femoral, tibial and patellar cartilage. For statistical evaluation, Pearson product–moment correlation coefficients and confidence intervals were computed. Results: Mean initial values were 35.7 ms for T2 and 25.1 ms for T2*. After the run, a significant decrease in the mean T2 and T2* relaxation times was observed for all segments in all participants. A mean decrease of relaxation time was observed for T2 with 4.6 ms (±3.6 ms) and for T2* with 3.6 ms (±5.1 ms) after running. Conclusion: A significant decrease could be observed in all cartilage segments for both biomarkers. Both quantitative techniques, T2 and T2*, seem to be valuable parameters in the evaluation of immediate changes in the cartilage ultrastructure after running. Advances in knowledge: This is the first direct comparison of immediate changes in T2 and T2* relaxation times after running in healthy adults. PMID:27336705

  9. The immediate effect of long-distance running on T2 and T2* relaxation times of articular cartilage of the knee in young healthy adults at 3.0 T MR imaging.

    PubMed

    Behzadi, Cyrus; Welsch, Goetz H; Laqmani, Azien; Henes, Frank O; Kaul, Michael G; Schoen, Gerhard; Adam, Gerhard; Regier, Marc

    2016-08-01

    To quantitatively assess the immediate effect of long-distance running on T2 and T2* relaxation times of the articular cartilage of the knee at 3.0 T in young healthy adults. 30 healthy male adults (18-31 years) who perform sports at an amateur level underwent an initial MRI at 3.0 T with T2 weighted [16 echo times (TEs): 9.7-154.6 ms] and T2* weighted (24 TEs: 4.6-53.6 ms) relaxation measurements. Thereafter, all participants performed a 45-min run. After the run, all individuals were immediately re-examined. Data sets were post-processed using dedicated software (ImageJ; National Institute of Health, Bethesda, MD). 22 regions of interest were manually drawn in segmented areas of the femoral, tibial and patellar cartilage. For statistical evaluation, Pearson product-moment correlation coefficients and confidence intervals were computed. Mean initial values were 35.7 ms for T2 and 25.1 ms for T2*. After the run, a significant decrease in the mean T2 and T2* relaxation times was observed for all segments in all participants. A mean decrease of relaxation time was observed for T2 with 4.6 ms (±3.6 ms) and for T2* with 3.6 ms (±5.1 ms) after running. A significant decrease could be observed in all cartilage segments for both biomarkers. Both quantitative techniques, T2 and T2*, seem to be valuable parameters in the evaluation of immediate changes in the cartilage ultrastructure after running. This is the first direct comparison of immediate changes in T2 and T2* relaxation times after running in healthy adults.

  10. Mitochondria‐targeted antioxidant MitoQ reduced renal damage caused by ischemia‐reperfusion injury in rodent kidneys: Longitudinal observations of T 2‐weighted imaging and dynamic contrast‐enhanced MRI

    PubMed Central

    Liu, Xiaoge; Murphy, Michael P.; Xing, Wei; Wu, Huanhuan; Zhang, Rui

    2017-01-01

    Purpose To investigate the effect of mitochondria‐targeted antioxidant MitoQ in reducing the severity of renal ischemia‐reperfusion injury (IRI) in rats using T2‐weighted imaging and dynamic contrast‐enhanced MRI (DCE‐MRI). Methods Ischemia‐reperfusion injury was induced by temporarily clamping the left renal artery. Rats were pretreated with MitoQ or saline. The MRI examination was performed before and after IRI (days 2, 5, 7, and 14). The T2‐weighted standardized signal intensity of the outer stripe of the outer medulla (OSOM) was measured. The unilateral renal clearance rate kcl was derived from DCE‐MRI. Histopathology was evaluated after the final MRI examination. Results The standardized signal intensity of the OSOM on IRI kidneys with MitoQ were lower than those with saline on days 5 and 7 (P = 0.004, P < 0.001, respectively). Kcl values of IRI kidneys with MitoQ were higher than those with saline at all time points (P = 0.002, P < 0.001, P = 0.001, P < 0.001). Histopathology showed that renal damage was the most predominant on the OSOM of IRI kidneys with saline, which was less obvious with MitoQ (P < 0.001). Conclusions These findings demonstrate that MitoQ can reduce the severity of renal damage in rodent IRI models using T2‐weighted imaging and DCE‐MRI. Magn Reson Med 79:1559–1667, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. PMID:28608403

  11. Feasibility of 3.0T pelvic MR imaging in the evaluation of endometriosis.

    PubMed

    Manganaro, L; Fierro, F; Tomei, A; Irimia, D; Lodise, P; Sergi, M E; Vinci, V; Sollazzo, P; Porpora, M G; Delfini, R; Vittori, G; Marini, M

    2012-06-01

    Endometriosis represents an important clinical problem in women of reproductive age with high impact on quality of life, work productivity and health care management. The aim of this study is to define the role of 3T magnetom system MRI in the evaluation of endometriosis. Forty-six women, with transvaginal (TV) ultrasound examination positive for endometriosis, with pelvic pain, or infertile underwent an MR 3.0T examination with the following protocol: T2 weighted FRFSE HR sequences, T2 weighted FRFSE HR CUBE 3D sequences, T1 w FSE sequences, LAVA-flex sequences. Pelvic anatomy, macroscopic endometriosis implants, deep endometriosis implants, fallopian tube involvement, adhesions presence, fluid effusion in Douglas pouch, uterus and kidney pathologies or anomalies associated and sacral nervous routes were considered by two radiologists in consensus. Laparoscopy was considered the gold standard. MRI imaging diagnosed deep endometriosis in 22/46 patients, endometriomas not associated to deep implants in 9/46 patients, 15/46 patients resulted negative for endometriosis, 11 of 22 patients with deep endometriosis reported ovarian endometriosis cyst. We obtained high percentages of sensibility (96.97%), specificity (100.00%), VPP (100.00%), VPN (92.86%). Pelvic MRI performed with 3T system guarantees high spatial and contrast resolution, providing accurate information about endometriosis implants, with a good pre-surgery mapping of the lesions involving both bowels and bladder surface and recto-uterine ligaments. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  12. Diffusion weighted imaging: a comprehensive evaluation of a fast spin echo DWI sequence with BLADE (PROPELLER) k-space sampling at 3 T, using a 32-channel head coil in acute brain ischemia.

    PubMed

    Attenberger, Ulrike I; Runge, Val M; Stemmer, Alto; Williams, Kenneth D; Naul, L Gill; Michaely, Henrik J; Schoenberg, Stefan O; Reiser, Maximilian F; Wintersperger, Bernd J

    2009-10-01

    To evaluate the signal-to-noise ratio (SNR) and diagnostic quality of diffusion weighted imaging (DWI) using a fast spin echo (FSE) sequence with BLADE k-space trajectory at 3 T in combination with a 32-channel head coil. The scan was compared with a standard spin echo (SE) echo-planar imaging (EPI) DWI and a high resolution SE EPI DWI sequence. Fourteen patients with acute brain ischemia were included in this Institutional Review Board approved study. All patients were evaluated with 3 different image sequences, using a 3 T scanner and a 32-channel head coil: (a) a standard SE EPI DWI (matrix size 192 x 192), (b) a high resolution SE EPI DWI (matrix size of 256 x 256) and (c) a FSE DWI BLADE (matrix size 192 x 192). The SNR of the 3 scans was compared in 10 healthy volunteers by a paired student t test. Image quality was evaluated with 4 dedicated questions in a blinded read: (1) The scans were ranked in terms of bulk susceptibility artifact. (2) The scan preference for diagnosis of any diffusion abnormality that might occur and (3) the preference for visualization of the diffusion abnormality actually present was determined. (4) The influence of bulk susceptibility on image evaluation for the diffusion abnormality present was assessed. For visualization of the diffusion abnormality present, BLADE DWI was the scan sequence preferred most by both readers (reader 1: 41.7%, reader 2: 35.7%). For visualization of any diffusion abnormality present, BLADE DWI was the preferred scan in 13 of 14 cases for reader 1 (93%) and in 11 of 14 cases for reader 2 (78.6%). No high resolution SE EPI DWI scan was rated best by reader 1. Reader 2 rated the high resolution SE EPI DWI scan superior in only 1 of 56 judgments. The standard EPI DWI sequence (21.8 +/- 5.3) had in comparison to the high resolution EPI DWI (11.9 +/- 2.6) and the BLADE DWI scans (11.3 +/- 3.8) significantly higher SNR mean values. Our preliminary data demonstrates the feasibility of a FSE EPI DWI scan with

  13. Evaluation of patellar chondromalacia with MR: comparison between T2-weighted FSE SPIR and GE MTC.

    PubMed

    Macarini, Luca; Perrone, Alessandra; Murrone, Mario; Marini, Stefania; Stefanelli, Michele

    2004-09-01

    To compare two different MR sequences to tissue signal suppression in the study of patellar cartilage abnormalities. We examined 26 patients with magnetic resonance (MR) imaging: sequences included spectral presaturation with inversion recovery (SPIR), with fat suppression and T2-weighted images, magnetization transfer contrast (MTC) sequences, T1-weighted and T2-weighted spin-echo sequences. All patients underwent conventional knee arthroscopy and in all patients a hyaline cartilage lesion was assessed in three articular zones: the patellar medial facet, the lateral facet and the patellar crista. Was assessed 78 articular facets. The lesions were classified using a standard arthroscopic grading system adapted to MR imaging: normal cartilage that corresponds to the grade 0 according to the Noyes grading system, low grade lesions that correspond to the grade I e IIa and high grade lesions that correspond to grades IIb and III. The arthroscopic results were compared with MR images. We assessed the MR diagnostic accuracy, sensitivity, specificity and MR positive predictive value and negative predictive value of the two sequences taking into consideration total lesions, and high-grade and low grade lesions separately. Twenty-four low grade lesions (16 grade I e 8 grade IIa) and 18 high grade lesions (10 grade IIb e 8 grade III) were diagnosed by arthroscopy. Regarding low grade and high-grade lesions together, the accuracy was 77% for MTC sequences and 90% for SPIR sequences. In identifying low-grade lesions, the sensitivity was 88% for SPIR sequence and 42% for MTC sequences. Specificity for the detection of all lesions was 89% for the SPIR sequences and 94% for the MTC sequences. The SPIR sequence visualised water content abnormalities in degenerating cartilage, which are representative of low-grade lesions. The sensitivity of the sequence enabled us to obtain improved contrast for detecting cartilage surface irregularities. The MTC sequences allowed us to grade high

  14. PET imaging of T cells: Target identification and feasibility assessment.

    PubMed

    Auberson, Yves P; Briard, Emmanuelle; Rudolph, Bettina; Kaupmann, Klemen; Smith, Paul; Oberhauser, Berndt

    2018-06-01

    Imaging T cells using positron emission tomography (PET) would be highly useful for diagnosis and monitoring in immunology and oncology patients. There are however no obvious targets that can be used to develop imaging agents for this purpose. We evaluated several potential target proteins with selective expression in T cells, and for which lead molecules were available: PKC , Lck, ZAP70 and Itk. Ultimately, we focused on Itk (interleukin-2-inducible T cell kinase) and identified a tool molecule with properties suitable for in vivo imaging of T cells, (5aR)-5,5-difluoro-5a-methyl-N-(1-((S)-3-(methylsulfonyl)-phenyl)(tetrahydro-2H-pyran-4-yl)methyl)-1H-pyrazol-4-yl)-1,4,4a,5,5a,6-hexahydro-cyclopropa[f]-indazole-3-carboxamide (23). While not having the optimal profile for clinical use, this molecule indicates that it might be possible to develop Itk-selective PET ligands for imaging the distribution of T cells in patients. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Cardiac MOLLI T1 mapping at 3.0 T: comparison of patient-adaptive dual-source RF and conventional RF transmission.

    PubMed

    Rasper, Michael; Nadjiri, Jonathan; Sträter, Alexandra S; Settles, Marcus; Laugwitz, Karl-Ludwig; Rummeny, Ernst J; Huber, Armin M

    2017-06-01

    To prospectively compare image quality and myocardial T 1 relaxation times of modified Look-Locker inversion recovery (MOLLI) imaging at 3.0 T (T) acquired with patient-adaptive dual-source (DS) and conventional single-source (SS) radiofrequency (RF) transmission. Pre- and post-contrast MOLLI T 1 mapping using SS and DS was acquired in 27 patients. Patient wise and segment wise analysis of T 1 times was performed. The correlation of DS MOLLI measurements with a reference spin echo sequence was analysed in phantom experiments. DS MOLLI imaging reduced T 1 standard deviation in 14 out of 16 myocardial segments (87.5%). Significant reduction of T 1 variance could be obtained in 7 segments (43.8%). DS significantly reduced myocardial T 1 variance in 16 out of 25 patients (64.0%). With conventional RF transmission, dielectric shading artefacts occurred in six patients causing diagnostic uncertainty. No according artefacts were found on DS images. DS image findings were in accordance with conventional T 1 mapping and late gadolinium enhancement (LGE) imaging. Phantom experiments demonstrated good correlation of myocardial T 1 time between DS MOLLI and spin echo imaging. Dual-source RF transmission enhances myocardial T 1 homogeneity in MOLLI imaging at 3.0 T. The reduction of signal inhomogeneities and artefacts due to dielectric shading is likely to enhance diagnostic confidence.

  16. Multi-model Analysis of Diffusion-weighted Imaging of Normal Testes at 3.0 T: Preliminary Findings.

    PubMed

    Min, Xiangde; Feng, Zhaoyan; Wang, Liang; Cai, Jie; Li, Basen; Ke, Zan; Zhang, Peipei; You, Huijuan; Yan, Xu

    2018-04-01

    This study aimed to establish diffusion quantitative parameters (apparent diffusion coefficient [ADC], DDC, α, D app , and K app ) in normal testes at 3.0 T. Sixty-four healthy volunteers in two age groups (A: 10-39 years; B: ≥ 40 years) underwent diffusion-weighted imaging scanning at 3.0 T. ADC 1000 , ADC 2000 , ADC 3000 , DDC, α, D app , and K app were calculated using the mono-exponential, stretched-exponential, and kurtosis models. The correlations between parameters and the age were analyzed. The parameters were compared between the age groups and between the right and the left testes. The average ADC 1000 , ADC 2000 , ADC 3000 , DDC, α, D app , and K app values did not significantly differ between the right and the left testes (P > .05 for all). The following significant correlations were found: positive correlations between age and testicular ADC 1000 , ADC 2000 , ADC 3000 , DDC, and D app (r = 0.516, 0.518, 0.518, 0.521, and 0.516, respectively; P < .01 for all) and negative correlations between age and testicular α and K app (r = -0.363, -0.427, respectively; P < .01 for both). Compared to group B, in group A, ADC 1000 , ADC 2000 , ADC 3000 , DDC, and D app were significantly lower (P < .05 for all), but α and K app were significantly higher (P < .05 for both). Our study demonstrated the applicability of the testicular mono-exponential, stretched-exponential, and kurtosis models. Our results can help establish a baseline for the normal testicular parameters in these diffusion models. The contralateral normal testis can serve as a suitable reference for evaluating the abnormalities of the other side. The effect of age on these parameters requires further attention. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  17. Non-enhanced magnetic resonance imaging of the small bowel at 7 Tesla in comparison to 1.5 Tesla: First steps towards clinical application.

    PubMed

    Hahnemann, Maria L; Kraff, Oliver; Maderwald, Stefan; Johst, Soeren; Orzada, Stephan; Umutlu, Lale; Ladd, Mark E; Quick, Harald H; Lauenstein, Thomas C

    2016-06-01

    To perform non-enhanced (NE) magnetic resonance imaging (MRI) of the small bowel at 7 Tesla (7T) and to compare it with 1.5 Tesla (1.5T). Twelve healthy subjects were prospectively examined using a 1.5T and 7T MRI system. Coronal and axial true fast imaging with steady-state precession (TrueFISP) imaging and a coronal T2-weighted (T2w) half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence were acquired. Image analysis was performed by 1) visual evaluation of tissue contrast and detail detectability, 2) measurement and calculation of contrast ratios and 3) assessment of artifacts. NE MRI of the small bowel at 7T was technically feasible. In the vast majority of the cases, tissue contrast and image details were equivalent at both field strengths. At 7T, two cases revealed better detail detectability in the TrueFISP, and better contrast in the HASTE. Susceptibility artifacts and B1 inhomogeneities were significantly increased at 7T. This study provides first insights into NE ultra-high field MRI of the small bowel and may be considered an important step towards high quality T2w abdominal imaging at 7T MRI. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Idiopathic and diabetic skeletal muscle necrosis: evaluation by magnetic resonance imaging.

    PubMed

    Kattapuram, Taj M; Suri, Rajeev; Rosol, Michael S; Rosenberg, Andrew E; Kattapuram, Susan V

    2005-04-01

    Idiopathic and diabetic-associated muscle necrosis are similar, uncommon clinical entities requiring conservative management and minimal intervention to avoid complications and prolonged hospitalization. An early noninvasive diagnosis is therefore essential. We evaluated the magnetic resonance imaging (MRI) characteristics of muscle necrosis in 14 patients, in eight of whom the diagnoses were confirmed histologically. Two experienced musculoskeletal radiologists performed retrospective evaluations of the MRI studies of 14 patients with the diagnoses of skeletal muscle infarction. In 10 cases gadolinium-enhanced (T1-weighted fat-suppressed) sequences were available along with T1-weighted, T2-weighted images and STIR sequences, while in four cases contrast-enhanced images were not available. Eight patients had underlying diabetes and in six patients the cause of the myonecrosis was considered idiopathic. T1-weighted images demonstrated isointense swelling of the involved muscle, with mildly displaced fascial planes. There was effacement of the fat signal intensity within the muscle. Fat-suppressed T2-weighted images showed diffuse heterogeneous high signal intensity in the muscles suggestive of edema. Perifascial fluid collection was seen in eight cases. Subcutaneous edema was present in seven patients. Following intravenous gadolinium administration, MRI demonstrated a focal area of heterogeneously enhancing mass with peripheral enhancement. Within this focal lesion, linear dark areas were seen with serpentine enhancing streaks separating them in eight cases. In two cases, a central relatively nonenhancing mass with irregular margins and peripheral enhancement was noted. The peripheral enhancement involved a significant part of the muscle. No focal fluid collection was noted. We believe that the constellation of imaging findings on T1- and T2-weighted images and post-gadolinium sequences is highly suggestive of muscle necrosis. We consider certain specific findings

  19. Diffusion-weighted imaging of mucinous carcinoma of the breast: evaluation of apparent diffusion coefficient and signal intensity in correlation with histologic findings.

    PubMed

    Woodhams, Reiko; Kakita, Satoko; Hata, Hirofumi; Iwabuchi, Keiichi; Umeoka, Shigeaki; Mountford, Carolyn E; Hatabu, Hiroto

    2009-07-01

    The purposes of this study were to compare the apparent diffusion coefficient (ADC) of mucinous carcinoma of the breast with that of other breast tumors and to analyze correlations between signal intensity on diffusion-weighted images and the histologic features of mucinous carcinoma. Two hundred seventy-six patients with 277 lesions, including 15 mucinous carcinomas (13 pure type, two mixed type), 204 other malignant tumors, and 58 benign lesions, were examined with 1.5-T MRI at b values of 0 and 1,500 s/mm(2). The correlations between cellularity and ADC, homogeneity of signal intensity on diffusion-weighted images, and histopathologic findings were analyzed. The difference was statistically significant (p < 0.05). The mean ADC of mucinous carcinoma (1.8 +/- 0.4 x 10(-3) mm(2)/s) was statistically higher than that of benign lesions (1.3+/- 0.3 x 10(-3) mm(2)/s) and other malignant tumors (0.9 +/- 0.2 x 10(-3) mm(2)/s) (p < 0.001). The ADC of pure type mucinous carcinoma (1.8 +/- 0.3 x 10(-3) mm(2)/s) was higher than that of mixed type mucinous carcinoma (1.2 +/- 0.2 x 10(-3) mm(2)/s) (p < 0.001) and other histologic types (p > 0.05). The correlation between mean cellularity and the ADC of mucinous carcinoma was significant (rho(s) = -0.754; p = 0.001). The homogeneity of signal intensity on diffusion-weighted images correlated with the homogeneity of histologic structures of mucinous carcinoma (p < 0.001; kappa = 0.826). Mucinous carcinoma can be clearly differentiated from other breast tumors on the basis of ADC. The low signal intensity of mucinous carcinoma on diffusion-weighted images appears to reflect the presence of mucin and low cellularity. High signal intensity on diffusion-weighted images may reflect the presence of fibrovascular bundles, increased cell density, or a combination of these features.

  20. Accuracy of magnetic resonance imaging in differentiating between benign and malignant vertebral lesions: role of diffusion-weighted imaging, in-phase/opposed-phase imaging and apparent diffusion coefficient.

    PubMed

    Martel Villagrán, J; Bueno Horcajadas, Á; Pérez Fernández, E; Martín Martín, S

    2015-01-01

    To determine the ability of MRI to distinguish between benign and malignant vertebral lesions. We included 85 patients and studied a total of 213 vertebrae (both pathologic and normal). For each vertebra, we determined whether the lesion was hypointense in T1-weighted sequences and whether it was hyperintense in STIR and in diffusion-weighted sequences. We calculated the in-phase/out-of-phase quotient and the apparent diffusion coefficient for each vertebra. We combined parameters from T1-weighted, diffusion-weighted, and STIR sequences to devise a formula to distinguish benign from malignant lesions. The group comprised 60 (70.6%) women and 25 (29.4%) men with a mean age of 67±13.5 years (range, 33-90 y). Of the 85 patients, 26 (30.6%) had a known primary tumor. When the lesion was hypointense on T1-weighted sequences, hyperintense on STIR and diffusion-weighted sequences, and had a signal intensity quotient greater than 0.8, the sensitivity was 97.2%, the specificity was 90%, and the diagnostic accuracy was 91.2%. If the patient had a known primary tumor, these values increased to 97.2%, 99.4%, and 99%, respectively. Benign lesions can be distinguished from malignant lesions if we combine the information from T1-weighted, STIR, and diffusion-weighted sequences together with the in-phase/out-of-phase quotient of the lesion detected in the vertebral body on MRI. Copyright © 2013 SERAM. Published by Elsevier España, S.L.U. All rights reserved.