Sample records for t1-201 myocardial perfusion

  1. Myocardial perfusion imaging with thallium-201: correlation with coronary arteriography and electrocardiography

    PubMed Central

    Sternberg, Leonard; Wald, Robert W.; Feiglin, David H.I.; Morch, John E.

    1978-01-01

    Myocardial perfusion imaging with thallium-201 and electrocardiography with the subject at rest and undergoing submaximal treadmill exercise were performed in 19 men and 3 women. Selective coronary arteriography and left ventriculography showed that 7 had normal coronary arteries and 15 had coronary artery disease. The 11 persons with electrocardiographic evidence of an old myocardial infarct (q waves) had a perfusion defect at rest in the area of the infarct and a segmental abnormality of wall motion apparent on the left ventriculogram corresponding to the perfusion defect. Myocardial perfusion imaging and electrocardiography were equally sensitive in detecting coronary artery disease in exercising individuals: perfusion defects were noted in 7 of the 15 persons with coronary artery disease, and diagnostic ST-segment depression was present in 8 of the 15. Combination of the results of the two tests with exercise permitted the identification of 11 of the 15 persons and improved the sensitivity. Combination of the results of rest and exercise imaging and electrocardiography permitted the identification of 94% of the patients with coronary artery disease. Myocardial perfusion imaging with 201TI in the subject at rest is a sensitive indicator of previous myocardial infarction. Imaging after the subject has exercised is a useful adjunct to conventional exercise electrocardiography, especially in those whose exercise electrocardiogram is non-interpretable. ImagesFIG. 1FIG. 2FIG. 3FIG. 4FIG. 5 PMID:630487

  2. Effects of atrial fibrillation on myocardial washout rate of thallium-201 on myocardial perfusion single-photon emission computed tomography.

    PubMed

    Kurisu, Satoshi; Nitta, Kazuhiro; Sumimoto, Yoji; Ikenaga, Hiroki; Ishibashi, Ken; Fukuda, Yukihiro; Kihara, Yasuki

    2018-04-20

    Myocardial perfusion single-photon emission computed tomography (SPECT) with thallium (Tl)-201 is an established modality for evaluating myocardial ischemia. We assessed the effects of atrial fibrillation (AF) on the myocardial washout rate (WR) of Tl-201 on myocardial perfusion SPECT. A total of 231 patients with no evidence of myocardial ischemia were enrolled retrospectively in this study. Patients were divided into two groups on the basis of the ECG at the time of myocardial perfusion SPECT. The mean myocardial WR of Tl-201 was calculated from the stress and the redistribution Bull's eye maps. There were 34 patients with AF and 197 patients with sinus rhythm. There were no significant differences in clinical variables, except for older age and higher heart rate in patients with AF. Myocardial WR of Tl-201 was significantly lower in patients with AF than those with sinus rhythm (46±12 vs. 51±8%, P=0.03). Multivariate analysis including these factors showed that female sex (β=0.18, P=0.02), AF (β=-0.14 P=0.03), hemoglobin (β=-0.18, P<0.01), and serum creatinine (β=0.24, P<0.01) were determinants of myocardial WR of Tl-201. Our data suggest that AF is associated with reduced myocardial WR of Tl-201 on myocardial perfuison SPECT.

  3. Reversibility by dipyridamole of thallium-201 myocardial scan defects in patients with sarcoidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tellier, P.; Paycha, F.; Antony, I.

    1988-08-01

    In order to clarify the significance of anginal pain and myocardial thallium-201 scan defects in cardiac sarcoidosis, the pharmacologic effect of dipyridamole on myocardial perfusion was assessed by planar thallium-201 myocardial scintigraphy in patients with sarcoidosis. Thallium-201 myocardial scintigraphy was performed at rest and after 0.56 mg/kg intravenous dipyridamole during four minutes in 16 patients with sarcoidosis. The myocardial scan (45-degree and 70-degree left anterior oblique, and anterior views) was divided into 15 segments. Results were evaluated by the number of segmental defects and with a global perfusion score (from 0 to 60) by a semi-quantitative index depending on themore » size and severity of myocardial thallium-201 defects. Thirteen of the 16 patients showed partial or total reversion of their thallium-201 defects on redistribution scanning either at rest or after dipyridamole. The mean (+/- SD) number of myocardial perfusion defects that were present in all the patients decreased from 5.31 +/- 1.78 at rest to 3.25 +/- 2.52 after redistribution (p less than 0.001) and to 2.19 +/- 2.10 after dipyridamole (p less than 0.001). The mean global perfusion score increased from 53.2 +/- 3.0 at rest to 56.2 +/- 2.9 after redistribution (p less than 0.001) and to 57.2 +/- 2.7 after dipyridamole (p less than 0.001). A significant correlation (r = 0.82, p less than 0.001) was found between the increase of global perfusion score on redistribution and after dipyridamole. The reversibility of myocardial scan defects is a common finding in sarcoidosis. It makes unlikely the role of scar fibrosis or extensive confluent granulomas as a mechanism for such defects. The effect of dipyridamole suggests the presence of reversible disorders lying at the coronary microvascular level.« less

  4. SU-C-201-04: Quantification of Perfusion Heterogeneity Based On Texture Analysis for Fully Automatic Detection of Ischemic Deficits From Myocardial Perfusion Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fang, Y; Huang, H; Su, T

    Purpose: Texture-based quantification of image heterogeneity has been a popular topic for imaging studies in recent years. As previous studies mainly focus on oncological applications, we report our recent efforts of applying such techniques on cardiac perfusion imaging. A fully automated procedure has been developed to perform texture analysis for measuring the image heterogeneity. Clinical data were used to evaluate the preliminary performance of such methods. Methods: Myocardial perfusion images of Thallium-201 scans were collected from 293 patients with suspected coronary artery disease. Each subject underwent a Tl-201 scan and a percutaneous coronary intervention (PCI) within three months. The PCImore » Result was used as the gold standard of coronary ischemia of more than 70% stenosis. Each Tl-201 scan was spatially normalized to an image template for fully automatic segmentation of the LV. The segmented voxel intensities were then carried into the texture analysis with our open-source software Chang Gung Image Texture Analysis toolbox (CGITA). To evaluate the clinical performance of the image heterogeneity for detecting the coronary stenosis, receiver operating characteristic (ROC) analysis was used to compute the overall accuracy, sensitivity and specificity as well as the area under curve (AUC). Those indices were compared to those obtained from the commercially available semi-automatic software QPS. Results: With the fully automatic procedure to quantify heterogeneity from Tl-201 scans, we were able to achieve a good discrimination with good accuracy (74%), sensitivity (73%), specificity (77%) and AUC of 0.82. Such performance is similar to those obtained from the semi-automatic QPS software that gives a sensitivity of 71% and specificity of 77%. Conclusion: Based on fully automatic procedures of data processing, our preliminary data indicate that the image heterogeneity of myocardial perfusion imaging can provide useful information for automatic

  5. Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects.

    PubMed

    Matsuo, Shinro; Nakajima, Kenichi; Onoguchi, Masahisa; Wakabayash, Hiroshi; Okuda, Koichi; Kinuya, Seigo

    2015-06-01

    A novel multifocal collimator, IQ-SPECT (Siemens) consists of SMARTZOOM, cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 ((201)Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging. Forty patients (eight women, mean age of 75 years) who underwent myocardial perfusion imaging were included in the study. All patients underwent one-day protocol perfusion scan after an adenosine-stress test and at rest after administering (201)Tl and showed normal results. Acquisition was performed on a Symbia T6 equipped with a conventional dual-headed gamma camera system (Siemens ECAM) and with a multifocal SMARTZOOM collimator. Imaging was performed with a conventional system followed by IQ-SPECT/computed tomography (CT). Reconstruction was performed with or without X-ray CT-derived attenuation correction (AC). Two nuclear physicians blinded to clinical information interpreted all myocardial perfusion images. A semi-quantitative myocardial perfusion was analyzed by a 17-segment model with a 5-point visual scoring. The uptake of each segment was measured and left ventricular functions were analyzed by QPS software. IQ-SPECT provided good or excellent image quality. The quality of IQ-SPECT images without AC was similar to those of conventional LEHR study. Mid-inferior defect score (0.3 ± 0.5) in the conventional LEHR study was increased significantly in IQ-SPECT with AC (0 ± 0). IQ-SPECT with AC improved the mid-inferior decreased perfusion shown in conventional images. The apical tracer count in IQ-SPECT with AC was decreased compared to that in LEHR (0.1 ± 0.3 vs. 0.5 ± 0.7, p < 0.05). The left ventricular ejection fraction from IQ-SPECT was significantly higher than that from the LEHR collimator (p = 0.0009). The images of IQ-SPECT acquired in a

  6. First-pass myocardial perfusion imaging with whole-heart coverage using L1-SPIRiT accelerated variable density spiral trajectories

    PubMed Central

    Yang, Yang; Kramer, Christopher M.; Shaw, Peter W.; Meyer, Craig H.; Salerno, Michael

    2015-01-01

    Purpose To design and evaluate 2D L1-SPIRiT accelerated spiral pulse sequences for first-pass myocardial perfusion imaging with whole heart coverage capable of measuring 8 slices at 2 mm in-plane resolution at heart rates up to 125 beats per minute (BPM). Methods Combinations of 5 different spiral trajectories and 4 k-t sampling patterns were retrospectively simulated in 25 fully sampled datasets and reconstructed with L1-SPIRiT to determine the best combination of parameters. Two candidate sequences were prospectively evaluated in 34 human subjects to assess in-vivo performance. Results A dual density broad transition spiral trajectory with either angularly uniform or golden angle in time k-t sampling pattern had the largest structural similarity (SSIM) and smallest root mean square error (RMSE) from the retrospective simulation, and the L1-SPIRiT reconstruction had well-preserved temporal dynamics. In vivo data demonstrated that both of the sampling patterns could produce high quality perfusion images with whole-heart coverage. Conclusion First-pass myocardial perfusion imaging using accelerated spirals with optimized trajectory and k-t sampling pattern can produce high quality 2D-perfusion images with wholeheart coverage at the heart rates up to 125 BPM. PMID:26538511

  7. First-pass myocardial perfusion imaging with whole-heart coverage using L1-SPIRiT accelerated variable density spiral trajectories.

    PubMed

    Yang, Yang; Kramer, Christopher M; Shaw, Peter W; Meyer, Craig H; Salerno, Michael

    2016-11-01

    To design and evaluate two-dimensional (2D) L1-SPIRiT accelerated spiral pulse sequences for first-pass myocardial perfusion imaging with whole heart coverage capable of measuring eight slices at 2 mm in-plane resolution at heart rates up to 125 beats per minute (BPM). Combinations of five different spiral trajectories and four k-t sampling patterns were retrospectively simulated in 25 fully sampled datasets and reconstructed with L1-SPIRiT to determine the best combination of parameters. Two candidate sequences were prospectively evaluated in 34 human subjects to assess in vivo performance. A dual density broad transition spiral trajectory with either angularly uniform or golden angle in time k-t sampling pattern had the largest structural similarity and smallest root mean square error from the retrospective simulation, and the L1-SPIRiT reconstruction had well-preserved temporal dynamics. In vivo data demonstrated that both of the sampling patterns could produce high quality perfusion images with whole-heart coverage. First-pass myocardial perfusion imaging using accelerated spirals with optimized trajectory and k-t sampling pattern can produce high quality 2D perfusion images with whole-heart coverage at the heart rates up to 125 BPM. Magn Reson Med 76:1375-1387, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.

  8. Normal results of post-race thallium-201 myocardial perfusion imaging in marathon runners with elevated serum MB creatine kinase levels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siegel, A.J.; Silverman, L.M.; Holman, B.L.

    1985-10-01

    Elevated cardiac enzyme values in asymptomatic marathon runners after competition can arise from skeletal muscle through exertional rhabdomyolysis, silent injury to the myocardium, or a combined tissue source. Peak post-race levels of the MB isoenzyme of creatine kinase are similar to values in patients with acute myocardial infarction. Previously reported normal results of infarct-avid myocardial scintigraphy with technetium 99m pyrophosphate in runners after competition suggest a non-cardiac source but cannot exclude silent injury to the myocardium. Therefore, thallium 201 myocardial perfusion imaging was performed in runners immediately after competition together with determination of sequential cardiac enzyme levels. Among 15 runnersmore » tested, the average peak in serum MB creatine kinase 24 hours after the race was 128 IU/liter with a cumulative MB creatine kinase release of 117 IU/liter; these values are comparable to those in patients with acute transmural myocardial infarction. Thallium 201 myocardial scintigraphic results were normal in five runners randomly selected from those who volunteered for determination of sequential blood levels. It is concluded that elevations of serum MB creatine kinase in marathon runners arise from a skeletal muscle source and that thallium 201 myocardial scintigraphy is useful to assess runners for myocardial injury when clinical questions arise.« less

  9. Myocardial perfusion characteristics during machine perfusion for heart transplantation.

    PubMed

    Peltz, Matthias; Cobert, Michael L; Rosenbaum, David H; West, LaShondra M; Jessen, Michael E

    2008-08-01

    Optimal parameters for machine perfusion preservation of hearts prior to transplantation have not been determined. We sought to define regional myocardial perfusion characteristics of a machine perfusion device over a range of conditions in a large animal model. Dog hearts were connected to a perfusion device (LifeCradle, Organ Transport Systems, Inc, Frisco, TX) and cold perfused at differing flow rates (1) at initial device startup and (2) over the storage interval. Myocardial perfusion was determined by entrapment of colored microspheres. Myocardial oxygen consumption (MVO(2)) was estimated from inflow and outflow oxygen differences. Intra-myocardial lactate was determined by (1)H magnetic resonance spectroscopy. MVO(2) and tissue perfusion increased up to flows of 15 mL/100 g/min, and the ratio of epicardial:endocardial perfusion remained near 1:1. Perfusion at lower flow rates and when low rates were applied during startup resulted in decreased capillary flow and greater non-nutrient flow. Increased tissue perfusion correlated with lower myocardial lactate accumulation but greater edema. Myocardial perfusion is influenced by flow rates during device startup and during the preservation interval. Relative declines in nutrient flow at low flow rates may reflect greater aortic insufficiency. These factors may need to be considered in clinical transplant protocols using machine perfusion.

  10. k-t SENSE-accelerated Myocardial Perfusion MR Imaging at 3.0 Tesla - comparison with 1.5 Tesla

    PubMed Central

    Plein, Sven; Schwitter, Juerg; Suerder, Daniel; Greenwood, John P.; Boesiger, Peter; Kozerke, Sebastian

    2008-01-01

    Purpose To determine the feasibility and diagnostic accuracy of high spatial resolution myocardial perfusion MR at 3.0 Tesla using k-space and time domain undersampling with sensitivity encoding (k-t SENSE). Materials and Methods The study was reviewed and approved by the local ethic review board. k-t SENSE perfusion MR was performed at 1.5 Tesla and 3.0 Tesla (saturation recovery gradient echo pulse sequence, repetition time/echo time 3.0ms/1.0ms, flip angle 15°, 5x k-t SENSE acceleration, spatial resolution 1.3×1.3×10mm3). Fourteen volunteers were studied at rest and 37 patients during adenosine stress. In volunteers, comparison was also made with standard-resolution (2.5×2.5×10mm3) 2x SENSE perfusion MR at 3.0 Tesla. Image quality, artifact scores, signal-to-noise ratios (SNR) and contrast-enhancement ratios (CER) were derived. In patients, diagnostic accuracy of visual analysis to detect >50% diameter stenosis on quantitative coronary angiography was determined by receiver-operator-characteristics (ROC). Results In volunteers, image quality and artifact scores were similar for 3.0 Tesla and 1.5 Tesla, while SNR was higher (11.6 vs. 5.6) and CER lower (1.1 vs. 1.5, p=0.012) at 3.0 Tesla. Compared with standard-resolution perfusion MR, image quality was higher for k-t SENSE (3.6 vs. 3.1, p=0.04), endocardial dark rim artifacts were reduced (artifact thickness 1.6mm vs. 2.4mm, p<0.001) and CER similar. In patients, area under the ROC curve for detection of coronary stenosis was 0.89 and 0.80, p=0.21 for 3.0 Tesla and 1.5 Tesla, respectively. Conclusions k-t SENSE accelerated high-resolution perfusion MR at 3.0 Tesla is feasible with similar artifacts and diagnostic accuracy as at 1.5 Tesla. Compared with standard-resolution perfusion MR, image quality is improved and artifacts are reduced. PMID:18936311

  11. Disagreement between splenic switch-off and myocardial T1-mapping after caffeine intake.

    PubMed

    Kuijpers, Dirkjan; van Dijk, Randy; van Assen, Marly; Kaandorp, Theodorus A M; van Dijkman, Paul R M; Vliegenthart, Rozemarijn; van der Harst, Pim; Oudkerk, Matthijs

    2018-04-01

    Caffeine is an adenosine receptor antagonist and a possible cause of inadequate stress perfusion. Splenic switch-off (SSO) and splenic rest-stress T1-mapping have been proposed as indicators of stress adequacy during perfusion cardiac magnetic resonance (CMR). We compared myocardial rest-stress T1-mapping with SSO and splenic rest-stress T1-mapping in patients with and without recent coffee intake. We analyzed 344 consecutive patients suspected of myocardial ischemia with adenosine perfusion CMR. All 146 normal CMR studies with a normal T1-rest of the myocardium, used as standard of reference, were included and divided in two groups. 22 patients accidentally ingested coffee < 4 h before CMR, compared to control group of 124 patients without self-reported coffee intake. Two independent readers graded SSO visually. T1-reactivity (ΔT1) was defined as percentual difference in T1-rest and T1-stress. Follow-up data were extracted from electronic patients records. In patients with recent coffee intake SSO was identified in 96%, which showed no significant difference with SSO in controls (94%, p = 0.835), however event rates were significantly different (13.6 and 0.8%, respectively (p < 0.001), median FU 17 months). Myocardial ΔT1 in the coffee group (- 5.2%) was significantly lower compared to control (+ 4.0%, p < 0.001), in contrast to the splenic ΔT1 (- 3.7 and - 4.0%, p = 0.789). The splenic T1-mapping results failed to predict false negative results. SSO and splenic rest-stress T1-mapping are not reliable indicators of stress adequacy in patients with recent coffee intake. Therefore, the dark spleen sign does not indicate adequate myocardial stress in patients with recent caffeine intake. Myocardial rest-stress T1-mapping is an excellent indicator of stress adequacy during adenosine perfusion CMR.

  12. [Evaluation of left ventricular perfusion and regional wall motion in myocardial infarction: using 201Tl myocardial SPECT and 99mTc-HSAD multigated cardiac blood pool emission computed tomography].

    PubMed

    Nanjyo, S

    1994-09-01

    In order to evaluate left ventricular regional wall motion and regional myocardial perfusion, 99mTc-HSAD multigated cardiac blood pool emission computed tomography (cardiac pool SPECT) and 201Tl myocardial SPECT (Tl) were performed on 12 patients with acute myocardial infarction (AMI), 6 patients had treated with only thrombolysis in group I and 6 patients had treated with thrombolysis and selective PTCA in group II, 17 patients with old myocardial infarction (OMI) in group III and 5 normal volunteers (controls). The relationship between left ventricular regional wall motion and regional myocardial perfusion was estimated. The relationship between % length shortening (%LS) by cardiac pool SPECT and %Tl uptake (%TU) was good (r = 0.820) in group III. The value for %TU in the segments of akinesia was low (35%) and in the those of severe hypokinesia was higher (48%). In all phases, two groups showed significant relationships between %LS and %TU in group I and II. The %TU was unchanged in the akinetic segment, the %LS changed 30% in group I and the %LS changed to 49% in group II. If the %TU is more than 50% (AMI) or 40% (OMI), we would observe viable muscle. The combination of Tl and cardiac pool SPECT are useful for evaluating myocardial viability in the patients with AMI.

  13. Myocardial perfusion abnormalities in asymptomatic patients with systemic lupus erythematosus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosenpud, J.D.; Montanaro, A.; Hart, M.V.

    1984-08-01

    Accelerated coronary artery disease and myocardial infarction in young patients with systemic lupus erythematosus is well documented; however, the prevalence of coronary involvement is unknown. Accordingly, 26 patients with systemic lupus were selected irrespective of previous cardiac history to undergo exercise thallium-201 cardiac scintigraphy. Segmental perfusion abnormalities were present in 10 of the 26 studies (38.5 percent). Five patients had reversible defects suggesting ischemia, four patients had persistent defects consistent with scar, and one patient had both reversible and persistent defects in two areas. There was no correlation between positive thallium results and duration of disease, amount of corticosteroid treatment,more » major organ system involvement or age. Only a history of pericarditis appeared to be associated with positive thallium-201 results (p less than 0.05). It is concluded that segmental myocardial perfusion abnormalities are common in patients with systemic lupus erythematosus. Whether this reflects large-vessel coronary disease or small-vessel abnormalities remains to be determined.« less

  14. Assessment of residual tissue viability by exercise testing in recent myocardial infarction: comparison of the electrocardiogram and myocardial perfusion scintigraphy.

    PubMed

    Margonato, A; Ballarotto, C; Bonetti, F; Cappelletti, A; Sciammarella, M; Cianflone, D; Chierchia, S L

    1992-04-01

    The assessment of residual myocardial viability in infarcted areas is relevant for subsequent management and prognosis but requires expensive technology. To evaluate the possibility that simple, easily obtainable clinical markers may detect the presence of within-infarct viable tissue, the significance of exercise-induced ST elevation occurring in leads exploring the area of a recent Q wave myocardial infarction was assessed. Twenty-five patients with recent (less than 6 months) myocardial infarction were studied. All had angiographically documented coronary artery disease, diagnostic Q waves (n = 24) or negative T waves (n = 25) on the rest 12-lead electrocardiogram and exhibited during exercise greater than or equal to 1.5 mm ST segment elevation (n = 17) or isolated T wave pseudonormalization (n = 8) in the infarct-related leads. ST-T wave changes were reproduced in all patients during thallium-201 exercise myocardial scintigraphy. A fixed perfusion defect was observed in 24 of the 25 patients. A reversible defect was seen in 16 (94%) of 17 patients who exhibited transient ST elevation during exercise but in only 4 (50%) of the 8 patients who had only T wave pseudonormalization. In conclusion, in patients with recent myocardial infarction, analysis of simple ST segment variables obtained during exercise testing may allow a first-line discrimination of those who may potentially benefit from a revascularization procedure.

  15. Myocardial scintigraphy with 201thallium in pediatric cardiology: A review of 52 cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bjoerkhem, G.E.; Evander, E.; White, T.

    1990-01-01

    We report our experience of myocardial scintigraphy with 201thallium (201Tl) in 52 children, aged 4 days to 18 years, in which 80 studies were made primarily to demonstrate or exclude impaired myocardial perfusion. For analysis, the patients were divided into the following eight groups: group I, coronary artery malformations (five patients); group II, Kawasaki's syndrome (six patients); group III, arterial switch operation (seven patients); group IV, dilated cardiomyopathy (18 patients); group V, hypertrophic cardiomyopathy (four patients); group VI, myocardial dysfunction after surgery for congenital heart disease (five patients); group VII, pulmonary atresia (three patients); and group VIII, miscellaneous (four patients).more » Myocardial scintigraphy was performed with a planar or tomographic technique at rest or after exercise (four patients). Isotope-uptake defects, indicating impaired myocardial perfusion, were present in 14 patients, including small infants. Defects were seen in all groups except those with hypertrophic cardiomyopathy and pulmonary atresia. The absence of such defects in several of the patients with Kawasaki's syndrome was particularly valuable as it made coronary angiography unnecessary. In the other groups of patients myocardial scintigraphy was a valuable adjunct to other investigations.« less

  16. The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

    PubMed

    Okudan, Berna; Smitherman, Thomas C

    2004-06-01

    Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2-day rest/stress Tc-99m sestamibi protocols are time-consuming. Hence, the dual isotope rest thallium-201/stress technetium-99m sestamibi gated single-photon emission tomography protocol has gained increasing popularity for these applications. Combining the use of thallium-201 with technetium-99m agents permits optimal image resolution and simultaneous assessment of viability. Dual-isotope imaging may be separate or simultaneous acquisition set-up. The more rapid completion of these studies is appreciated as an advantage by patients, technologists, interpreting and referring physicians, nurses and hospital management. Simultaneous imaging has the potential advantages of precise pixel registration and artifacts, if present, are identical in both thallium and sestamibi, and require only one set of imaging. Also, there are some disadvantages of spillover of activity from the Tc-99m to the Tl-201 window. Fortunately, despite this problem it can be overcome. Separate acquisition dual isotope also has some disadvantages. Difference in defect resolution in attenuation and scatter between T-201 and Tc-99m sestamibi potentially results in interpretation problems. But, studies about cost-effectiveness of dual isotope imaging showed that some selective elimination of the rest studies may decrease the cost of the nuclear procedures and should be considered in the current care health system.

  17. [Myokard-Perfusions-SPECT. Myocardial perfusion SPECT - Update S1 guideline].

    PubMed

    Lindner, Oliver; Bengel, Frank; Burchert, Wolfgang; Dörr, Rolf; Hacker, Marcus; Schäfer, Wolfgang; Schäfers, Michael A; Schmidt, Matthias; Schwaiger, Markus; Vom Dahl, Jürgen; Zimmermann, Rainer

    2017-08-14

    The S1 guideline for myocardial perfusion SPECT has been published by the Association of the Scientific Medical Societies in Germany (AWMF) and is valid until 2/2022. This paper is a short summary with comments on all chapters and subchapters wich were modified and amended.

  18. Myocardial perfusion and left ventricular function indices assessed by gated myocardial perfusion SPECT in methamphetamine abusers.

    PubMed

    Dadpour, Bita; Dabbagh Kakhki, Vahid R; Afshari, Reza; Dorri-Giv, Masoumeh; Mohajeri, Seyed A R; Ghahremani, Somayeh

    2016-12-01

    Methamphetamine (MA) is associated with alterations of cardiac structure and function, although it is less known. In this study, we assessed possible abnormality in myocardial perfusion and left ventricular function using gated myocardial perfusion SPECT. Fifteen patients with MA abuse, on the basis of Diagnostic and Statistical Manual of Mental Disorders, 4th ed. (DSM-IV) MA dependency determined by Structured Clinical Interview for DSM-IV, underwent 2-day dipyridamole stress/rest Tc-sestamibi gated myocardial perfusion SPECT. An average daily dose of MA use was 0.91±1.1 (0.2-4) g. The duration of MA use was 3.4±2.1 (1-7) years. In visual and semiquantitative analyses, all patients had normal gated myocardial perfusion SPECT, with no perfusion defects. In all gated SPECT images, there was no abnormality in left ventricular wall motion and thickening. All summed stress scores and summed rest scores were below 3. Calculated left ventricular functional indices including the end-diastolic volume, end-systolic volume, and left ventricular ejection fraction were normal. Many cardiac findings because of MA mentioned in previous reports are less likely because of significant epicardial coronary artery stenosis.

  19. IQ-SPECT for thallium-201 myocardial perfusion imaging: effect of normal databases on quantification.

    PubMed

    Konishi, Takahiro; Nakajima, Kenichi; Okuda, Koichi; Yoneyama, Hiroto; Matsuo, Shinro; Shibutani, Takayuki; Onoguchi, Masahisa; Kinuya, Seigo

    2017-07-01

    Although IQ-single-photon emission computed tomography (SPECT) provides rapid acquisition and attenuation-corrected images, the unique technology may create characteristic distribution different from the conventional imaging. This study aimed to compare the diagnostic performance of IQ-SPECT using Japanese normal databases (NDBs) with that of the conventional SPECT for thallium-201 ( 201 Tl) myocardial perfusion imaging (MPI). A total of 36 patients underwent 1-day 201 Tl adenosine stress-rest MPI. Images were acquired with IQ-SPECT at approximately one-quarter of the standard time of conventional SPECT. Projection data acquired with the IQ-SPECT system were reconstructed via an ordered subset conjugate gradient minimizer method with or without scatter and attenuation correction (SCAC). Projection data obtained using the conventional SPECT were reconstructed via a filtered back projection method without SCAC. The summed stress score (SSS) was calculated using NDBs created by the Japanese Society of Nuclear Medicine working group, and scores were compared between IQ-SPECT and conventional SPECT using the acquisition condition-matched NDBs. The diagnostic performance of the methods for the detection of coronary artery disease was also compared. SSSs were 6.6 ± 8.2 for the conventional SPECT, 6.6 ± 9.4 for IQ-SPECT without SCAC, and 6.5 ± 9.7 for IQ-SPECT with SCAC (p = n.s. for each comparison). The SSS showed a strong positive correlation between conventional SPECT and IQ-SPECT (r = 0.921 and p < 0.0001), and the correlation between IQ-SPECT with and without SCAC was also good (r = 0.907 and p < 0.0001). Regarding diagnostic performance, the sensitivity, specificity, and accuracy were 80.8, 78.9, and 79.4%, respectively, for the conventional SPECT; 80.8, 80.3, and 82.0%, respectively, for IQ-SPECT without SCAC; and 88.5, 86.8, and 87.3%, respectively, for IQ-SPECT with SCAC, respectively. The area under the curve obtained via receiver operating

  20. Creation and characterization of normal myocardial perfusion imaging databases using the IQ·SPECT system.

    PubMed

    Okuda, Koichi; Nakajima, Kenichi; Matsuo, Shinro; Kondo, Chisato; Sarai, Masayoshi; Horiguchi, Yoriko; Konishi, Takahiro; Onoguchi, Masahisa; Shimizu, Takeshi; Kinuya, Seigo

    2017-01-03

    Image acquisition by short-time single-photon emission-computed tomography (SPECT) has been made feasible by IQ·SPECT. The aim of this study was to generate normal databases (NDBs) of thallium-201 ( 201 Tl) myocardial perfusion imaging for IQ·SPECT, and characterize myocardial perfusion distribution. We retrospectively enrolled 159 patients with a low likelihood of cardiac diseases from four hospitals in Japan. All patients underwent short-time 201 Tl myocardial perfusion IQ·SPECT with or without attenuation and scatter correction (ACSC) in either supine or prone position. The mean myocardial counts were calculated using 17-segment polar maps. Three NDBs were derived from supine and prone images as well as supine images with ACSC. Differences between the supine and prone positions were observed in the uncorrected sex-segregated NDBs in the mid-inferolateral counts (p ≤ 0.016 for males and p ≤ 0.002 for females). Differences between IQ·SPECT and conventional SPECT were also observed in the mid-anterior, inferolateral, and apical lateral counts (p ≤ 0.009 for males and p ≤ 0.003 for females). Apical low counts attributed to myocardial thinning were observed in the apical anterior and apex segments in the supine IQ·SPECT NDB with ACSC. There were significant differences between uncorrected supine and prone NDBs, between uncorrected supine NDB and supine NDB with ACSC, and between uncorrected supine NDB and conventional SPECT NDB. Understanding the pattern of normal distribution in IQ-SPECT short-time acquisitions with and without ACSC will be helpful for interpretation of imaging findings in patients with coronary artery disease (CAD) or low likelihood of CAD and the NDBs will aid in quantitative analysis.

  1. Assessment of stenosis severity: Correlation of angiography, T1-201 scintigraphy, and intracoronary pressure gradients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bateman, T.; Raymond, M.; Czer, L.

    1984-01-01

    To clarify the relationship between angiographic and hemodynamic stenosis severity and the appearance during stress-redistribution myocardial T1-201 scintigraphy (Ex-T1) of a visual (V) or quantitative (Q) perfusion defect (PD) or washout (WO) abnormality, 24 pts with CAD underwent intracoronary pressure gradient study at bypass surgery (CABG). All had pre-CABG Ex-T1 without interval deterioration. The mean diastolic pressure gradient (MDG) measured at reproducible hyperemic flow rates was determined for 34 stenoses (13 LAD, 7 LCX, 14 RCA) and compared with the results of Ex-T1 in subtended myocardial regions (LAD=anterior; LCX=posterolateral; RCA=inferior). Fourteen stenoses (50-99% diameter narrowing) were unassociated with VPD despitemore » maximal exercise: MDG was 9 +- 5mmHg, with MDG/mean aortic diastolic pressure (ADP) ratio of 0.12 +- 0.07. QPD and QWO analysis detected 8 of these. Thirteen stenoses (90-100% severity) led to reversible VPD: MDG was 36 +- 11 mm Hg, MDG/ADP ratio was 0.52 +- 0.17, and Q analysis was abnormal in 12/13. Seven stenoses (90-100% severity) subtended infarcted myocardium: MDG was 42 +- 21 mm Hg, MDG/ADP ratio was 0.52 +- 0.18, and V and Q analyses were abnormal in all. From this study, the authors derive the following conclusion: 1) Ex-T1 correlates better with hemodynamic severity of stenoses than does angiography; 2) V abnormalities identify stenoses of major angiographic and hemodynamic severity, while Q analysis detects some (57% in this study) stenoses of lesser severity; and 3) stenoses causing reversible Ex-T1 abnormalities present similar hemodynamic impediments to those causing myocardial infarcts.« less

  2. Myocardial contusion in patients with blunt chest trauma as evaluated by thallium 201 myocardial scintigraphy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bodin, L.; Rouby, J.J.; Viars, P.

    1988-07-01

    Fifty five patients suffering from blunt chest trauma were studied to assess the diagnosis of myocardial contusion using thallium 201 myocardial scintigraphy. Thirty-eight patients had consistent scintigraphic defects and were considered to have a myocardial contusion. All patients with scintigraphic defects had paroxysmal arrhythmias and/or ECG abnormalities. Of 38 patients, 32 had localized ST-T segment abnormalities; 29, ST-T segment abnormalities suggesting involvement of the same cardiac area as scintigraphic defects; 21, echocardiographic abnormalities. Sixteen patients had segmental hypokinesia involving the same cardiac area as the scintigraphic defects. Fifteen patients had clinical signs suggestive of myocardial contusion and scintigraphic defects. Almostmore » 70 percent of patients with blunt chest trauma had scintigraphic defects related to areas of myocardial contusion. When thallium 201 myocardial scintigraphy directly showed myocardial lesion, two-dimensional echocardiography and standard ECG detected related functional consequences of cardiac trauma.« less

  3. Comparison of personnel radiation dosimetry from myocardial perfusion scintigraphy: Technetium-99m-sestamibi versus thallium-201

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Culver, C.M.; Dworkin, H.J.

    1993-07-01

    The whole-body and hand radiation doses to our technical staff were retrospectively compared for three distinct 4-mo periods when either 201TI or 99mTc-sestamibi were exclusively used for stress myocardial perfusion imaging. During the initial 4-mo period when 99mTc-sestamibi replaced 201TI, the mean whole-body film badge readings increased from 100 to 450 microSv/mo (p < 0.001) for nuclear medicine technologists (n = 10) and from 240 to 560 microSv/mo (p < 0.05) for radiopharmacy technologists (n = 2). Mean TLD readings to the hands also increased, although the differences were not statistically significant for the nuclear medicine technologists. Noninvasive cardiology staffmore » were monitored with film badges and the mean whole-body film badge reading, when 99mTc-sestamibi was the imaging agent, was 360 microSv per month. Radiation reduction methods that decreased radiation exposure to staff were utilized. The most effective included the use of a lead face shield and lead lined storage container in the noninvasive imaging area, handling spills by shielding instead of decontamination and methods to reduce time spent in close proximity to the patient.« less

  4. Myocardial perfusion imaging with PET

    PubMed Central

    Nakazato, Ryo; Berman, Daniel S; Alexanderson, Erick; Slomka, Piotr

    2013-01-01

    PET-myocardial perfusion imaging (MPI) allows accurate measurement of myocardial perfusion, absolute myocardial blood flow and function at stress and rest in a single study session performed in approximately 30 min. Various PET tracers are available for MPI, and rubidium-82 or nitrogen-13-ammonia is most commonly used. In addition, a new fluorine-18-based PET-MPI tracer is currently being evaluated. Relative quantification of PET perfusion images shows very high diagnostic accuracy for detection of obstructive coronary artery disease. Dynamic myocardial blood flow analysis has demonstrated additional prognostic value beyond relative perfusion imaging. Patient radiation dose can be reduced and image quality can be improved with latest advances in PET/CT equipment. Simultaneous assessment of both anatomy and perfusion by hybrid PET/CT can result in improved diagnostic accuracy. Compared with SPECT-MPI, PET-MPI provides higher diagnostic accuracy, using lower radiation doses during a shorter examination time period for the detection of coronary artery disease. PMID:23671459

  5. Investigation of optimal acquisition time of myocardial perfusion scintigraphy using cardiac focusing-collimator

    NASA Astrophysics Data System (ADS)

    Niwa, Arisa; Abe, Shinji; Fujita, Naotoshi; Kono, Hidetaka; Odagawa, Tetsuro; Fujita, Yusuke; Tsuchiya, Saki; Kato, Katsuhiko

    2015-03-01

    Recently myocardial perfusion SPECT imaging acquired using the cardiac focusing-collimator (CF) has been developed in the field of nuclear cardiology. Previously we have investigated the basic characteristics of CF using physical phantoms. This study was aimed at determining the acquisition time for CF that enables to acquire the SPECT images equivalent to those acquired by the conventional method in 201TlCl myocardial perfusion SPECT. In this study, Siemens Symbia T6 was used by setting the torso phantom equipped with the cardiac, pulmonary, and hepatic components. 201TlCl solution were filled in the left ventricular (LV) myocardium and liver. Each of CF, the low energy high resolution collimator (LEHR), and the low medium energy general purpose collimator (LMEGP) was set on the SPECT equipment. Data acquisitions were made by regarding the center of the phantom as the center of the heart in CF at various acquisition times. Acquired data were reconstructed, and the polar maps were created from the reconstructed images. Coefficient of variation (CV) was calculated as the mean counts determined on the polar maps with their standard deviations. When CF was used, CV was lower at longer acquisition times. CV calculated from the polar maps acquired using CF at 2.83 min of acquisition time was equivalent to CV calculated from those acquired using LEHR in a 180°acquisition range at 20 min of acquisition time.

  6. Myocardial perfusion imaging with technetium-99m SQ30217: Comparison with thallium-201 and coronary anatomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seldin, D.W.; Johnson, L.L.; Blood, D.K.

    1989-03-01

    Myocardial perfusion in ten normal volunteers and 20 patients with coronary artery disease documented by recent coronary arteriography was studied with 99mTc-labeled SQ30217 and /sup 201/TI. Plantar /sup 201/TI imaging followed standard treadmill exercise and planar SQ30217 imaging followed upright bicycle exercise, performed to angina, or the same double product achieved on the treadmill test. Upright anterior, 30 degrees left anterior oblique, and 60 degrees left anterior oblique images were obtained for 3, 6, and 9 min, respectively, starting 2 min after injection of 15 mCi of 99mTc SQ30217. A second 15-mCi dose was injected at rest approximately 2 hrmore » later, and the same imaging protocol was followed. No adverse reactions or laboratory abnormalities attributable to SQ30217 were observed. All scans on the normal volunteers were interpreted as normal. Qualitative readings of both tests were equally sensitive for detecting patients with coronary disease (SQ30217 - 16/20, TI - 17/20, p = NS) and identifying abnormal vessels (SQ30217 - 19/45, TI - 21/45, p = NS). Both agents were falsely positive in 1/15 vessels. Ten vascular regions showed persistent abnormalities on resting SQ30217 scans; eight of these were distal to stenoses of at least 90% and three were also abnormal on thallium redistribution images. Hepatic uptake of SQ30217 obscured inferoapical segments in some views in 14/20 patients but did not interfere with abnormal vessel identification.« less

  7. Comparison of conventional and cadmium-zinc-telluride single-photon emission computed tomography for analysis of thallium-201 myocardial perfusion imaging: an exploratory study in normal databases for different ethnicities.

    PubMed

    Ishihara, Masaru; Onoguchi, Masahisa; Taniguchi, Yasuyo; Shibutani, Takayuki

    2017-12-01

    The aim of this study was to clarify the differences in thallium-201-chloride (thallium-201) myocardial perfusion imaging (MPI) scans evaluated by conventional anger-type single-photon emission computed tomography (conventional SPECT) versus cadmium-zinc-telluride SPECT (CZT SPECT) imaging in normal databases for different ethnic groups. MPI scans from 81 consecutive Japanese patients were examined using conventional SPECT and CZT SPECT and analyzed with the pre-installed quantitative perfusion SPECT (QPS) software. We compared the summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) for the two SPECT devices. For a normal MPI reference, we usually use Japanese databases for MPI created by the Japanese Society of Nuclear Medicine, which can be used with conventional SPECT but not with CZT SPECT. In this study, we used new Japanese normal databases constructed in our institution to compare conventional and CZT SPECT. Compared with conventional SPECT, CZT SPECT showed lower SSS (p < 0.001), SRS (p = 0.001), and SDS (p = 0.189) using the pre-installed SPECT database. In contrast, CZT SPECT showed no significant difference from conventional SPECT in QPS analysis using the normal databases from our institution. Myocardial perfusion analyses by CZT SPECT should be evaluated using normal databases based on the ethnic group being evaluated.

  8. Validation and evaluation of model-based crosstalk compensation method in simultaneous /sup 99m/Tc stress and /sup 201/Tl rest myocardial perfusion SPECT

    NASA Astrophysics Data System (ADS)

    Song, X.; Frey, E. C.; Wang, W. T.; Du, Y.; Tsui, B. M. W.

    2004-02-01

    Simultaneous acquisition of /sup 99m/Tc stress and /sup 201/Tl rest myocardial perfusion SPECT has several potential advantages, but the image quality is degraded by crosstalk between the Tc and Tl data. We have previously developed a crosstalk model that includes estimates of the downscatter and Pb X-ray for use in crosstalk compensation. In this work, we validated the model by comparing the crosstalk from /sup 99m/Tc to the Tl window calculated using a combination of the SimSET-MCNP Monte Carlo simulation codes. We also evaluated the model-based crosstalk compensation method using both simulated data from the 3-D MCAT phantom and experimental data from a physical phantom with a myocardial defect. In these studies, the Tl distributions were reconstructed from crosstalk contaminated data without crosstalk compensation, with compensation using the model-based crosstalk estimate, and with compensation using the known true crosstalk, and were compared with the Tl distribution reconstructed from uncontaminated Tl data. Results show that the model gave good estimates of both the downscatter photons and Pb X-rays in the simultaneous dual-isotopes myocardial perfusion SPECT. The model-based compensation method provided image quality that was significantly improved as compared to no compensation and was very close to that from the separate acquisition.

  9. Relationship between HgbA1c and myocardial blood flow reserve in patients with type 2 diabetes mellitus: noninvasive assessment using real-time myocardial perfusion echocardiography.

    PubMed

    Huang, Runqing; Abdelmoneim, Sahar S; Nhola, Lara F; Mulvagh, Sharon L

    2014-01-01

    To study the relationship between glycosylated hemoglobin (HgbA1c) and myocardial perfusion in type 2 diabetes mellitus (T2DM) patients, we prospectively enrolled 24 patients with known or suspected coronary artery disease (CAD) who underwent adenosine stress by real-time myocardial perfusion echocardiography (RTMPE). HgbA1c was measured at time of RTMPE. Microbubble velocity (β min(-1)), myocardial blood flow (MBF, mL/min/g), and myocardial blood flow reserve (MBFR) were quantified. Quantitative MCE analysis was feasible in all patients (272/384 segments, 71%). Those with HgbA1c > 7.1% had significantly lower βreserve and MBFR than those with HgbA1c ≤ 7.1% (P < 0.05). In patients with suspected CAD, there was a significant inverse correlation between MBFR and HgbA1c (r = -0.279, P = 0.01); however, in those with known CAD, this relationship was not significant (r = -0.117, P = 0.129). Using a MBFR cutoff value > 2 as normal, HgbA1c > 7.1% significantly increased the risk for abnormal MBFR, (adjusted odds ratio: 1.92, 95% CI: 1.12-3.35, P = 0.02). Optimal glycemic control is associated with preservation of MBFR as determined by RTMPE, in T2DM patients at risk for CAD.

  10. High-resolution myocardial stress perfusion at 3 T in patients with suspected coronary artery disease.

    PubMed

    Meyer, Carsten; Strach, Katharina; Thomas, Daniel; Litt, Harold; Nähle, Claas P; Tiemann, Klaus; Schwenger, Ulrich; Schild, Hans H; Sommer, Torsten

    2008-02-01

    To implement a high-resolution first-pass myocardial perfusion imaging protocol (HRPI) at 3 T, and to evaluate the feasibility, image quality and accuracy of this approach prospectively in patients with suspected CAD. We hypothesized that utilizing the gain in SNR at 3 T to increase spatial resolution would reduce partial volume effects and subendocardial dark rim artifacts in comparison to 1.5 T. HRPI studies were performed on 60 patients using a segmented k-space gradient echo sequence (in plane resolution 1.97 x 1.94 mm(2)). Semiquantitative assessment of dark rim artifacts was performed for the stress studies on a slice-by-slice basis. Qualitative visual analysis was compared to quantitative coronary angiography (QCA) results; hemodynamically significant CAD was defined as stenosis >or=70% at QCA. Dark rim artifacts appeared in 108 of 180 slices (average extent 1.3 +/- 1.2 mm representing 11.8 +/- 10.8% of the transmural myocardial thickness). Sensitivity, specifity, and test accuracy for the detection of significant CAD were 89%,79%, and 85%. HRPI studies at 3 T are feasible in a clinical setting, providing good image quality and high accuracy for detection of significant CAD. The presence of dark rim artifacts does not appear to represent a diagnostic problem when using a HRPI approach.

  11. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    PubMed

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  12. Nuclear cardiology. I - Radionuclide angiographic assessment of left ventricular contraction: uses, limitations and future directions. II - The role of myocardial perfusion imaging using thallium-201 in diagnosis of coronary heart disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bodenheimer, M.M.; Banka, V.S.; Helfant, R.H.

    1980-01-01

    The current status of radionuclide angiography is reviewed. First pass and gated equilibrium methods for determining left ventricular contraction are compared. Some clinical applications of radionuclide angiography are then examined, including the detection of discrete versus diffuse asynergy and the assessment of myocardial infarction. The second part of this work reviews the uses and limitations of thallium-201 perfusion imaging in the diagnosis of the acute and chronic manifestations of coronary heart disease. Theoretical and technical considerations of thallium-201 imaging are reviewed along with the clinical implications of the technique.

  13. False-negative dipyridamole-thallium-201 myocardial imaging after caffeine infusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smits, P.; Corstens, F.H.; Aengevaeren, W.R.

    1991-08-01

    The vasodilator effect of intravenously administered dipyridamole may be caused by an increase in endogenous plasma adenosine levels. The authors evaluated the effect of caffeine, an adenosine receptor antagonist, on the diagnostic results of dipyridamole-201Tl myocardial imaging in eight patients with coronary artery disease. Caffeine infusion significantly attenuated the dipyridamole-induced fall in blood pressure and the accompanied increase in heart rate. The infusion of dipyridamole alone resulted in chest pain and ST-segment depressions on the electrocardiogram in four patients, whereas none of these problems occurred when the tests were repeated after caffeine. In six of eight patients, caffeine was responsiblemore » for false-negative dipyridamole-201Tl tests. Semiquantitive scores of the dipyridamole-induced 201Tl perfusion defects were decreased by caffeine from 9.0 {plus minus} 0.9 to 2.0 {plus minus} 1.1 points (p less than 0.05). Computerized analysis revealed a caffeine-mediated reduction in the percent reversibility of the images from 46% {plus minus} 16% to 6% {plus minus} 10% (p less than 0.05). They conclude that the use of caffeinated products prior to dipyridamole-201Tl testing may be responsible for false-negative findings.« less

  14. Meta-Analysis of Stress Myocardial Perfusion Imaging

    ClinicalTrials.gov

    2017-06-06

    Coronary Disease; Echocardiography; Fractional Flow Reserve, Myocardial; Hemodynamics; Humans; Magnetic Resonance Imaging; Myocardial Perfusion Imaging; Perfusion; Predictive Value of Tests; Single Photon Emission Computed Tomography; Positron Emission Tomography; Multidetector Computed Tomography; Echocardiography, Stress; Coronary Angiography

  15. Quantification of myocardial perfusion based on signal intensity of flow sensitized MRI

    NASA Astrophysics Data System (ADS)

    Abeykoon, Sumeda B.

    The quantitative assessment of perfusion is important for early recognition of a variety of heart diseases, determination of disease severity and their cure. In conventional approach of measuring cardiac perfusion by arterial spin labeling, the relative difference in the apparent T1 relaxation times in response to selective and non-selective inversion of blood entering the region of interest is related to perfusion via a two-compartment tissue model. But accurate determination of T1 in small animal hearts is difficult and prone to errors due to long scan times. The purpose of this study is to develop a fast, robust and simple method to quantitatively assess myocardial perfusion using arterial spin labeling. The proposed method is based on signal intensities (SI) of inversion recovery slice-select, non-select and steady-state images. Especially in this method data are acquired at a single inversion time and at short repetition times. This study began by investigating the accuracy of assessment of perfusion using a two compartment system. First, determination of perfusion by T1 and SI were implemented to a simple, two-compartment phantom model. Mathematical model developed for full spin exchange models (in-vivo experiments) by solving a modified Bloch equation was modified to develop mathematical models (T1 and SI) for a phantom (zero spin exchange). The phantom result at different flow rates shows remarkable evidence of accuracy of the two-compartment model and SI, T1 methods: the SI method has less propagation error and less scan time. Next, twelve healthy C57BL/6 mice were scanned for quantitative perfusion assessment and three of them were repeatedly scanned at three different time points for a reproducibility test. The myocardial perfusion of healthy mice obtained by the SI-method, 5.7+/-1.6 ml/g/min, was similar (p=0.38) to that obtained by the conventional T1 method, 5.6+/- 2.3 ml/g/min. The reproducibility of the SI method shows acceptable results: the

  16. An alternative method for neonatal cerebro-myocardial perfusion.

    PubMed

    Luciani, Giovanni Battista; De Rita, Fabrizio; Faggian, Giuseppe; Mazzucco, Alessandro

    2012-05-01

    Several techniques have already been described for selective cerebral perfusion during repair of aortic arch pathology in children. One method combining cerebral with myocardial perfusion has also been proposed. A novel technique is reported here for selective and independent cerebro-myocardial perfusion for neonatal and infant arch surgery. Technical aspects and potential advantages are discussed.

  17. An alternative method for neonatal cerebro-myocardial perfusion

    PubMed Central

    Luciani, Giovanni Battista; De Rita, Fabrizio; Faggian, Giuseppe; Mazzucco, Alessandro

    2012-01-01

    Several techniques have already been described for selective cerebral perfusion during repair of aortic arch pathology in children. One method combining cerebral with myocardial perfusion has also been proposed. A novel technique is reported here for selective and independent cerebro-myocardial perfusion for neonatal and infant arch surgery. Technical aspects and potential advantages are discussed. PMID:22307393

  18. Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strydhorst, Jared H., E-mail: jared.strydhorst@gmail.com; Ruddy, Terrence D.; Wells, R. Glenn

    2015-04-15

    Purpose: Our goal in this work was to investigate the impact of CT-based attenuation correction on measurements of rat myocardial perfusion with {sup 99m}Tc and {sup 201}Tl single photon emission computed tomography (SPECT). Methods: Eight male Sprague-Dawley rats were injected with {sup 99m}Tc-tetrofosmin and scanned in a small animal pinhole SPECT/CT scanner. Scans were repeated weekly over a period of 5 weeks. Eight additional rats were injected with {sup 201}Tl and also scanned following a similar protocol. The images were reconstructed with and without attenuation correction, and the relative perfusion was analyzed with the commercial cardiac analysis software. The absolutemore » uptake of {sup 99m}Tc in the heart was also quantified with and without attenuation correction. Results: For {sup 99m}Tc imaging, relative segmental perfusion changed by up to +2.1%/−1.8% as a result of attenuation correction. Relative changes of +3.6%/−1.0% were observed for the {sup 201}Tl images. Interscan and inter-rat reproducibilities of relative segmental perfusion were 2.7% and 3.9%, respectively, for the uncorrected {sup 99m}Tc scans, and 3.6% and 4.3%, respectively, for the {sup 201}Tl scans, and were not significantly affected by attenuation correction for either tracer. Attenuation correction also significantly increased the measured absolute uptake of tetrofosmin and significantly altered the relationship between the rat weight and tracer uptake. Conclusions: Our results show that attenuation correction has a small but statistically significant impact on the relative perfusion measurements in some segments of the heart and does not adversely affect reproducibility. Attenuation correction had a small but statistically significant impact on measured absolute tracer uptake.« less

  19. Do thallium myocardial perfusion scan abnormalities predict survival in sarcoid patients without cardiac symptoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinney, E.L.; Caldwell, J.W.

    1990-07-01

    Whereas the total mortality rate for sarcoidosis is 0.2 per 100,000, the prognosis, when the heart is involved, is very much worse. The authors used the difference in mortality rate to infer whether thallium 201 myocardial perfusion scan abnormalities correspond to myocardial sarcoid by making the simplifying assumption that if they do, then patients with abnormal scans will be found to have a death rate similar to patients with sarcoid heart disease. The authors therefore analyzed complete survival data on 52 sarcoid patients without cardiac symptoms an average of eighty-nine months after they had been scanned as part of amore » protocol. By use of survival analysis (the Cox proportional hazards model), the only variable that was significantly associated with survival was age. The patients' scan pattern, treatment status, gender, and race were not significantly related to survival. The authors conclude that thallium myocardial perfusion scans cannot reliably be used to diagnose sarcoid heart disease in sarcoid patients without cardiac symptoms.« less

  20. External detection of regional myocardial metabolism with radioiodinated hexadecenoic acid in the dog heart.

    PubMed

    van der Wall, E E; Westera, G; den Hollander, W; Visser, F C

    1981-04-01

    In a previous study we have demonstrated that terminally iodinated hexadecenoic acid (131I-HA) and Thallium-201 (201T1) are comparable in myocardial uptake and distribution in the ischemic dog heart (Westera et al. 1980). In the present study the potential value of 131I-HA was proved in determining regional myocardial metabolism in 19 dog experiments. In ten dogs, 131I-HA was administered 5 min after occlusion of a coronary artery (group II), in six dogs after a 90 min occlusion period (group III). Three dogs served as controls (group I). The turnover rates (t 1/2) of 131I-HA were calculated from mono-exponential time-activity curves, obtained by external detection over ischemic and normally perfused areas during a 30 min period after IV injection of 0.7-1.5 mCi 131I-HA. The t 1/2 values in ischemic regions were found to be significantly longer (group II, 25.1 +/- 2.6 min; group III, 22.6 +/- 1.8 min) than in non-ischemic areas (group II, 12.5 +/- 1.8 min; group III, 14.2 +/- 1.4 min). The t 1/2 values in the control dogs (group I, 13.4 +/- 1.4 min) were not significantly different from the turnover rates in the non-ischemic areas of the occluded hearts. We conclude that the study of turnover rates of radioiodinated free fatty acids allows the determination of regional myocardial metabolism and offers a means to distinguish normally perfused from ischemic myocardial tissue.

  1. Accelerating free breathing myocardial perfusion MRI using multi coil radial k - t SLR

    NASA Astrophysics Data System (ADS)

    Goud Lingala, Sajan; DiBella, Edward; Adluru, Ganesh; McGann, Christopher; Jacob, Mathews

    2013-10-01

    The clinical utility of myocardial perfusion MR imaging (MPI) is often restricted by the inability of current acquisition schemes to simultaneously achieve high spatio-temporal resolution, good volume coverage, and high signal to noise ratio. Moreover, many subjects often find it difficult to hold their breath for sufficiently long durations making it difficult to obtain reliable MPI data. Accelerated acquisition of free breathing MPI data can overcome some of these challenges. Recently, an algorithm termed as k - t SLR has been proposed to accelerate dynamic MRI by exploiting sparsity and low rank properties of dynamic MRI data. The main focus of this paper is to further improve k - t SLR and demonstrate its utility in considerably accelerating free breathing MPI. We extend its previous implementation to account for multi-coil radial MPI acquisitions. We perform k - t sampling experiments to compare different radial trajectories and determine the best sampling pattern. We also introduce a novel augmented Lagrangian framework to considerably improve the algorithm’s convergence rate. The proposed algorithm is validated using free breathing rest and stress radial perfusion data sets from two normal subjects and one patient with ischemia. k - t SLR was observed to provide faithful reconstructions at high acceleration levels with minimal artifacts compared to existing MPI acceleration schemes such as spatio-temporal constrained reconstruction and k - t SPARSE/SENSE.

  2. Accelerating free breathing myocardial perfusion MRI using multi coil radial k-t SLR

    PubMed Central

    Lingala, Sajan Goud; DiBella, Edward; Adluru, Ganesh; McGann, Christopher; Jacob, Mathews

    2013-01-01

    The clinical utility of myocardial perfusion MR imaging (MPI) is often restricted by the inability of current acquisition schemes to simultaneously achieve high spatio-temporal resolution, good volume coverage, and high signal to noise ratio. Moreover, many subjects often find it difficult to hold their breath for sufficiently long durations making it difficult to obtain reliable MPI data. Accelerated acquisition of free breathing MPI data can overcome some of these challenges. Recently, an algorithm termed as k − t SLR has been proposed to accelerate dynamic MRI by exploiting sparsity and low rank properties of dynamic MRI data. The main focus of this paper is to further improve k − t SLR and demonstrate its utility in considerably accelerating free breathing MPI. We extend its previous implementation to account for multi-coil radial MPI acquisitions. We perform k − t sampling experiments to compare different radial trajectories and determine the best sampling pattern. We also introduce a novel augmented Lagrangian framework to considerably improve the algorithm's convergence rate. The proposed algorithm is validated using free breathing rest and stress radial perfusion data sets from two normal subjects and one patient with ischemia. k − t SLR was observed to provide faithful reconstructions at high acceleration levels with minimal artifacts compared to existing MPI acceleration schemes such as spatio-temporal constrained reconstruction (STCR) and k − t SPARSE/SENSE. PMID:24077063

  3. Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification.

    PubMed

    Kellman, Peter; Hansen, Michael S; Nielles-Vallespin, Sonia; Nickander, Jannike; Themudo, Raquel; Ugander, Martin; Xue, Hui

    2017-04-07

    Quantification of myocardial blood flow requires knowledge of the amount of contrast agent in the myocardial tissue and the arterial input function (AIF) driving the delivery of this contrast agent. Accurate quantification is challenged by the lack of linearity between the measured signal and contrast agent concentration. This work characterizes sources of non-linearity and presents a systematic approach to accurate measurements of contrast agent concentration in both blood and myocardium. A dual sequence approach with separate pulse sequences for AIF and myocardial tissue allowed separate optimization of parameters for blood and myocardium. A systems approach to the overall design was taken to achieve linearity between signal and contrast agent concentration. Conversion of signal intensity values to contrast agent concentration was achieved through a combination of surface coil sensitivity correction, Bloch simulation based look-up table correction, and in the case of the AIF measurement, correction of T2* losses. Validation of signal correction was performed in phantoms, and values for peak AIF concentration and myocardial flow are provided for 29 normal subjects for rest and adenosine stress. For phantoms, the measured fits were within 5% for both AIF and myocardium. In healthy volunteers the peak [Gd] was 3.5 ± 1.2 for stress and 4.4 ± 1.2 mmol/L for rest. The T2* in the left ventricle blood pool at peak AIF was approximately 10 ms. The peak-to-valley ratio was 5.6 for the raw signal intensities without correction, and was 8.3 for the look-up-table (LUT) corrected AIF which represents approximately 48% correction. Without T2* correction the myocardial blood flow estimates are overestimated by approximately 10%. The signal-to-noise ratio of the myocardial signal at peak enhancement (1.5 T) was 17.7 ± 6.6 at stress and the peak [Gd] was 0.49 ± 0.15 mmol/L. The estimated perfusion flow was 3.9 ± 0.38 and 1.03 ± 0.19

  4. Quantitative Myocardial Perfusion Imaging Versus Visual Analysis in Diagnosing Myocardial Ischemia: A CE-MARC Substudy.

    PubMed

    Biglands, John D; Ibraheem, Montasir; Magee, Derek R; Radjenovic, Aleksandra; Plein, Sven; Greenwood, John P

    2018-05-01

    This study sought to compare the diagnostic accuracy of visual and quantitative analyses of myocardial perfusion cardiovascular magnetic resonance against a reference standard of quantitative coronary angiography. Visual analysis of perfusion cardiovascular magnetic resonance studies for assessing myocardial perfusion has been shown to have high diagnostic accuracy for coronary artery disease. However, only a few small studies have assessed the diagnostic accuracy of quantitative myocardial perfusion. This retrospective study included 128 patients randomly selected from the CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) study population such that the distribution of risk factors and disease status was proportionate to the full population. Visual analysis results of cardiovascular magnetic resonance perfusion images, by consensus of 2 expert readers, were taken from the original study reports. Quantitative myocardial blood flow estimates were obtained using Fermi-constrained deconvolution. The reference standard for myocardial ischemia was a quantitative coronary x-ray angiogram stenosis severity of ≥70% diameter in any coronary artery of >2 mm diameter, or ≥50% in the left main stem. Diagnostic performance was calculated using receiver-operating characteristic curve analysis. The area under the curve for visual analysis was 0.88 (95% confidence interval: 0.81 to 0.95) with a sensitivity of 81.0% (95% confidence interval: 69.1% to 92.8%) and specificity of 86.0% (95% confidence interval: 78.7% to 93.4%). For quantitative stress myocardial blood flow the area under the curve was 0.89 (95% confidence interval: 0.83 to 0.96) with a sensitivity of 87.5% (95% confidence interval: 77.3% to 97.7%) and specificity of 84.5% (95% confidence interval: 76.8% to 92.3%). There was no statistically significant difference between the diagnostic performance of quantitative and visual analyses (p = 0.72). Incorporating rest myocardial

  5. Thallium myocardial perfusion scans for the assessment of right ventricular hypertrophy in patients with cystic fibrosis. A comparison with other noninvasive techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Newth, C.J.; Corey, M.L.; Fowler, R.S.

    1981-01-01

    The incidence of right ventricular hypertrophy in 32 patients with cystic fibrosis was studied using thallium 201 (TI-201) myocardial perfusion scans, and compared with other noninvasive techniques including electrocardiography, vectorcardiography, and M-mode echocardiography. The patients (mean age, 17.3 yr; range, 7 to 33) had a wide range of clinical and pulmonary abnormalities (mean Shwachman-Kulczycki score, 66.6). In the total study group, TI-201 scans, like the vectorcardiograms and the M-mode echocardiograms, gave a surprisingly high proportion of positive predictions for right ventricular hypertrophy (RVH) (44%). The correlations with all other noninvasive methods were uniformly poor, so caution must be exercised inmore » using this technique to predict early RVH in order to follow the natural history of cor pulmonale in cystic fibrosis. At the time of the study, 6 patients had clinical evidence of right ventricular failure, and in this disease setting must have had RVH. In 3 patients, RVH was confirmed at autopsy, and it was successfully predicted by TI-201 scans in 5 of the 6 patients. The false negative scan may have been due to regional myocardial ischemia secondary to severe right ventricular failure. In contrast, the vectorcardiogram, using Fowler's new criteria, made a successful prediction of RVH in all 6 patients, and the electro cardiogram in only 3. Although the M-mode echocardiogram was abnormal in all patients, it would have predicted RVH (with increased right ventricular anterior wall thickness) in only 1 patient. We concluded that TI-201 myocardial perfusion cans are good at confirming RVH in cases with established right ventricular failure, but have no advantage over vectorcardiographic assessments, which are logistically easier to perform and carry no radiation risks.« less

  6. Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    PubMed

    Natsume, Takahiro; Ishida, Masaki; Kitagawa, Kakuya; Nagata, Motonori; Sakuma, Hajime; Ichihara, Takashi

    2015-11-01

    The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models requires faithful recording of contrast content in the blood and myocardium. Typically, the arterial input function (AIF) is obtained by setting a region of interest in the left ventricular cavity. However, there is a small delay between the AIF and the myocardial curves, and such time discrepancies can lead to errors in flow estimation using Patlak plot analysis. In this study, the time discrepancies between the arterial TSI curve and the myocardial tissue TSI curve were estimated based on the compartment model. In the early phase after the arrival of the contrast agent in the myocardium, the relationship between rate constant K1 and the concentrations of Gd-DTPA contrast agent in the myocardium and arterial blood (LV blood) can be described by the equation K1={dCmyo(tpeak)/dt}/Ca(tpeak), where Cmyo(t) and Ca(t) are the relative concentrations of Gd-DTPA contrast agent in the myocardium and in the LV blood, respectively, and tpeak is the time corresponding to the peak of Ca(t). In the ideal case, the time corresponding to the maximum upslope of Cmyo(t), tmax, is equal to tpeak. In practice, however, there is a small difference in the arrival times of the contrast agent into the LV and into the myocardium. This difference was estimated to correspond to the difference between tpeak and tmax. The magnitudes of such time discrepancies and the effectiveness of the correction for these time discrepancies were measured in 18 subjects who underwent myocardial perfusion MRI under rest and stress conditions. The effects of the time discrepancies could be corrected effectively in the myocardial perfusion estimates. Copyright © 2015 Elsevier Inc. All rights

  7. Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tao, Yinghua; Chen, Guang-Hong; Hacker, Timothy A.

    Purpose: Dynamic CT myocardial perfusion imaging has the potential to provide both functional and anatomical information regarding coronary artery stenosis. However, radiation dose can be potentially high due to repeated scanning of the same region. The purpose of this study is to investigate the use of statistical iterative reconstruction to improve parametric maps of myocardial perfusion derived from a low tube current dynamic CT acquisition. Methods: Four pigs underwent high (500 mA) and low (25 mA) dose dynamic CT myocardial perfusion scans with and without coronary occlusion. To delineate the affected myocardial territory, an N-13 ammonia PET perfusion scan wasmore » performed for each animal in each occlusion state. Filtered backprojection (FBP) reconstruction was first applied to all CT data sets. Then, a statistical iterative reconstruction (SIR) method was applied to data sets acquired at low dose. Image voxel noise was matched between the low dose SIR and high dose FBP reconstructions. CT perfusion maps were compared among the low dose FBP, low dose SIR and high dose FBP reconstructions. Numerical simulations of a dynamic CT scan at high and low dose (20:1 ratio) were performed to quantitatively evaluate SIR and FBP performance in terms of flow map accuracy, precision, dose efficiency, and spatial resolution. Results: Forin vivo studies, the 500 mA FBP maps gave −88.4%, −96.0%, −76.7%, and −65.8% flow change in the occluded anterior region compared to the open-coronary scans (four animals). The percent changes in the 25 mA SIR maps were in good agreement, measuring −94.7%, −81.6%, −84.0%, and −72.2%. The 25 mA FBP maps gave unreliable flow measurements due to streaks caused by photon starvation (percent changes of +137.4%, +71.0%, −11.8%, and −3.5%). Agreement between 25 mA SIR and 500 mA FBP global flow was −9.7%, 8.8%, −3.1%, and 26.4%. The average variability of flow measurements in a nonoccluded region was 16.3%, 24.1%, and

  8. Protective effect of active perfusion in porcine models of acute myocardial ischemia

    PubMed Central

    Feng, Zanxiang; Mao, Zhifu; Dong, Shengjun; Liu, Baohui

    2016-01-01

    Mortality rates associated with off-pump coronary artery bypass (CAB) are relatively high, as the majority of patients requiring CAB are at a high risk for cardiac events. The present study aimed to establish porcine models of acute myocardial ischemia, and evaluate the protective role of shunt and active perfusion. A total of 30 pigs were randomly assigned to five groups, as follows: i) Sham (control); ii) A1 (shunt; stenosis rate, 55%); iii) A2 (shunt; stenosis rate, 75%); iv) B1 (active perfusion; stenosis rate, 55%); and v) B2 (active perfusion; stenosis rate, 75%) groups. Aortic pressure (P0), left anterior descending coronary pressure (P1), and coronary effective perfusion pressure (P1/P0) were measured. The expression levels of tumor necrosis factor-α (TNF-α), cardiac troponin (cTnI), creatine kinase-myocardial band (CK-MB), interleukin (IL)-6, IL-10, B-cell lymphoma 2 (Bcl-2), and caspase-3 were detected using enzyme-linked immunosorbent assay or western blotting. The myocardial apoptosis rate was determined using the terminal deoxynucleotidyl transferase dUTP nick end labeling assay. Ischemia models with stenosis rates of 55 and 75% were successfully constructed following suturing of the descending artery. Compared with the control, the 55 and 75% stenosis groups demonstrated significantly decreased P1/P0, increased expression levels of TNF-α, cTnI, CK-MB, IL-6, IL-10 and caspase-3, an increased rate of myocardial apoptosis, and a decreased expression level of anti-apoptotic protein, Bcl-2. At 30 min following successful establishment of the model (ST segment elevation to 1 mm), group B demonstrated significantly increased P1/P0, decreased expression levels of TNF-α, cTnI, CK-MB, IL-6, IL-10 and caspase-3, a decreased rate of myocardial apoptosis, and an increased expression level of anti-apoptotic protein, Bcl-2. Furthermore, the current study indicated that active perfusion was more efficacious in maintaining myocardial perfusion and alleviating

  9. New imaging technology: measurement of myocardial perfusion by contrast echocardiography

    NASA Technical Reports Server (NTRS)

    Rubin, D. N.; Thomas, J. D.

    2000-01-01

    Myocardial perfusion imaging has long been a goal for the non-invasive echocardiographic assessment of the heart. However, many factors at play in perfusion imaging have made this goal elusive. Harmonic imaging and triggered imaging with newer contrast agents have made myocardial perfusion imaging potentially practical in the very near future. The application of indicator dilution theory to the coronary circulation and bubble contrast agents is fraught with complexities and sources of error. Therefore, quantification of myocardial perfusion by non-invasive echocardiographic imaging requires further investigation in order to make this technique clinically viable.

  10. Visualisation of exercise-induced ischaemia of the right ventricle by thallium-201 single photon emission computed tomography.

    PubMed Central

    Chiba, J.; Takeishi, Y.; Abe, S.; Tomoike, H.

    1997-01-01

    OBJECTIVE: Exercise thallium-201 (201T1) single photon emission computed tomography (SPECT) has been used to detect potential ischaemia in the left ventricular myocardium but not in the right ventricle. The purpose of this study was to establish the clinical usefulness of a right ventricular polar map of 201T1 SPECT for visualisation of exercise-induced right ventricular ischaemia. METHODS: Myocardial 201T1 SPECT was obtained immediately after treadmill exercise in 97 patients with suspected coronary artery disease. A region of interest was placed over the right ventricle (RV) on post-stress transaxial images. Short axis images of this region were generated and reconstructed as a bull's eye polar map. Normal ranges of RV 201T1 uptake were determined in 12 patients with normal coronary arteries. Scintigraphic criteria for identifying RV perfusion abnormality were derived from 25 patients with right coronary artery (RCA) stenosis greater than 75%. These criteria were applied to 60 consecutive patients with suspected coronary artery disease. RESULTS: Perfusion defects in the RV were larger in patients with proximal RCA stenosis than in those with distal RCA stenosis (mean (SD) 28 (16)% v 6 (5)%, P < 0.001). The sensitivity and specificity of the RV polar map for the detection of proximal RCA stenosis were 67% (8/12) and 98% (47/48), respectively. RV perfusion defects became undetectable in 9 patients who had successful percutaneous transluminal coronary angioplasty to a proximal RCA lesion. CONCLUSIONS: A right ventricular polar map display was useful for visualising exercise-induced right ventricular ischaemia. Images PMID:9038692

  11. Simultaneous Myocardial Strain and Dark-Blood Perfusion Imaging Using a Displacement-Encoded MRI Pulse Sequence

    PubMed Central

    Le, Yuan; Stein, Ashley; Berry, Colin; Kellman, Peter; Bennett, Eric E.; Taylor, Joni; Lucas, Katherine; Kopace, Rael; Chefd’Hotel, Christophe; Lorenz, Christine H.; Croisille, Pierre; Wen, Han

    2010-01-01

    The purpose of this study is to develop and evaluate a displacement-encoded pulse sequence for simultaneous perfusion and strain imaging. Displacement-encoded images in 2–3 myocardial slices were repeatedly acquired using a single shot pulse sequence for 3 to 4 minutes, which covers a bolus infusion of Gd. The magnitudes of the images were T1 weighted and provided quantitative measures of perfusion, while the phase maps yielded strain measurements. In an acute coronary occlusion swine protocol (n=9), segmental perfusion measurements were validated against microsphere reference standard with a linear regression (slope 0.986, R2 = 0.765, Bland-Altman standard deviation = 0.15 ml/min/g). In a group of ST-elevation myocardial infarction(STEMI) patients (n=11), the scan success rate was 76%. Short-term contrast washout rate and perfusion are highly correlated (R2=0.72), and the pixel-wise relationship between circumferential strain and perfusion was better described with a sigmoidal Hill curve than linear functions. This study demonstrates the feasibility of measuring strain and perfusion from a single set of images. PMID:20544714

  12. SPECT imaging with Tl-201 and Ga-67 in myocardial sarcoidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurata, C.; Sakata, K.; Taguchi, T.

    1990-06-01

    Two patients with myocardial sarcoidosis are presented, both of whom underwent SPECT imaging with Tl-201 and Ga-67. The first had Ga-67 myocardial uptake with a Tl-201 defect, which disappeared with corticosteroid therapy. The second had multiple Tl-201 defects without Ga-67 uptake, which persisted despite corticosteroid therapy. Therefore, the combination of Tl-201 and Ga-67 imaging may be useful for recognizing myocardial sarcoidosis and for predicting the response to corticosteroid therapy.

  13. Optimal reproducibility of gated sestamibi and thallium myocardial perfusion study left ventricular ejection fractions obtained on a solid-state CZT cardiac camera requires operator input.

    PubMed

    Cherk, Martin H; Ky, Jason; Yap, Kenneth S K; Campbell, Patrina; McGrath, Catherine; Bailey, Michael; Kalff, Victor

    2012-08-01

    To evaluate the reproducibility of serial re-acquisitions of gated Tl-201 and Tc-99m sestamibi left ventricular ejection fraction (LVEF) measurements obtained on a new generation solid-state cardiac camera system during myocardial perfusion imaging and the importance of manual operator optimization of left ventricular wall tracking. Resting blinded automated (auto) and manual operator optimized (opt) LVEF measurements were measured using ECT toolbox (ECT) and Cedars-Sinai QGS software in two separate cohorts of 55 Tc-99m sestamibi (MIBI) and 50 thallium (Tl-201) myocardial perfusion studies (MPS) acquired in both supine and prone positions on a cadmium zinc telluride (CZT) solid-state camera system. Resting supine and prone automated LVEF measurements were similarly obtained in a further separate cohort of 52 gated cardiac blood pool scans (GCBPS) for validation of methodology and comparison. Appropriate use of Bland-Altman, chi-squared and Levene's equality of variance tests was used to analyse the resultant data comparisons. For all radiotracer and software combinations, manual checking and optimization of valve planes (+/- centre radius with ECT software) resulted in significant improvement in MPS LVEF reproducibility that approached that of planar GCBPS. No difference was demonstrated between optimized MIBI/Tl-201 QGS and planar GCBPS LVEF reproducibility (P = .17 and P = .48, respectively). ECT required significantly more manual optimization compared to QGS software in both supine and prone positions independent of radiotracer used (P < .02). Reproducibility of gated sestamibi and Tl-201 LVEF measurements obtained during myocardial perfusion imaging with ECT toolbox or QGS software packages using a new generation solid-state cardiac camera with improved image quality approaches that of planar GCBPS however requires visual quality control and operator optimization of left ventricular wall tracking for best results. Using this superior cardiac technology, Tl-201

  14. Measurement of myocardial perfusion and infarction size using computer-aided diagnosis system for myocardial contrast echocardiography.

    PubMed

    Du, Guo-Qing; Xue, Jing-Yi; Guo, Yanhui; Chen, Shuang; Du, Pei; Wu, Yan; Wang, Yu-Hang; Zong, Li-Qiu; Tian, Jia-Wei

    2015-09-01

    Proper evaluation of myocardial microvascular perfusion and assessment of infarct size is critical for clinicians. We have developed a novel computer-aided diagnosis (CAD) approach for myocardial contrast echocardiography (MCE) to measure myocardial perfusion and infarct size. Rabbits underwent 15 min of coronary occlusion followed by reperfusion (group I, n = 15) or 60 min of coronary occlusion followed by reperfusion (group II, n = 15). Myocardial contrast echocardiography was performed before and 7 d after ischemia/reperfusion, and images were analyzed with the CAD system on the basis of eliminating particle swarm optimization clustering analysis. The myocardium was quickly and accurately detected using contrast-enhanced images, myocardial perfusion was quantitatively calibrated and a color-coded map calibrated by contrast intensity and automatically produced by the CAD system was used to outline the infarction region. Calibrated contrast intensity was significantly lower in infarct regions than in non-infarct regions, allowing differentiation of abnormal and normal myocardial perfusion. Receiver operating characteristic curve analysis documented that -54-pixel contrast intensity was an optimal cutoff point for the identification of infarcted myocardium with a sensitivity of 95.45% and specificity of 87.50%. Infarct sizes obtained using myocardial perfusion defect analysis of original contrast images and the contrast intensity-based color-coded map in computerized images were compared with infarct sizes measured using triphenyltetrazolium chloride staining. Use of the proposed CAD approach provided observers with more information. The infarct sizes obtained with myocardial perfusion defect analysis, the contrast intensity-based color-coded map and triphenyltetrazolium chloride staining were 23.72 ± 8.41%, 21.77 ± 7.8% and 18.21 ± 4.40% (% left ventricle) respectively (p > 0.05), indicating that computerized myocardial contrast echocardiography can

  15. Myocardial perfusion MRI with sliding-window conjugate-gradient HYPR.

    PubMed

    Ge, Lan; Kino, Aya; Griswold, Mark; Mistretta, Charles; Carr, James C; Li, Debiao

    2009-10-01

    First-pass perfusion MRI is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. In this study we investigated the feasibility of using a method that combines sliding window and CG-HYPR methods (SW-CG-HYPR) to reduce the acquisition window for each slice while maintaining the temporal resolution of one frame per heartbeat in myocardial perfusion MRI. This method allows an increased number of slices, reduced motion artifacts, and preserves the relatively high SNR and spatial resolution of the "composite images." Results from eight volunteers demonstrate the feasibility of SW-CG-HYPR for accelerated myocardial perfusion imaging with accurate signal intensity changes of left ventricle blood pool and myocardium. Using this method the acquisition time per cardiac cycle was reduced by a factor of 4 and the number of slices was increased from 3 to 8 as compared to the conventional technique. The SNR of the myocardium at peak enhancement with SW-CG-HYPR (13.83 +/- 2.60) was significantly higher (P < 0.05) than the conventional turbo-FLASH protocol (8.40 +/- 1.62). Also, the spatial resolution of the myocardial perfection images was significantly improved. SW-CG-HYPR is a promising technique for myocardial perfusion MRI. (c) 2009 Wiley-Liss, Inc.

  16. Transmyocardial laser revascularization in the acute ischaemic heart: no improvement of acute myocardial perfusion or prevention of myocardial infarction.

    PubMed

    Eckstein, F S; Scheule, A M; Vogel, U; Schmid, S T; Miller, S; Jurmann, M J; Ziemer, G

    1999-05-01

    Transmyocardial laser revascularization (TMLR) has been used to provide enhanced myocardial perfusion in patients not suitable for coronary revascularization or angioplasty. This study investigates the acute changes in myocardial perfusion after TMLR with a Holmium:Yttrium-Aluminium-Garnet (YAG) laser with a thermal imaging camera in a model of acute ischaemia, and confirms its midterm effects by post-mortem investigation of magnetic resonance imaging and histopathological examination. Acute myocardial ischaemia was induced by occlusion of the dominant diagonal branch in ten sheep. Perfusion measurements were undertaken first in the unaffected myocardium, then after temporary occlusion of the coronary to obtain a control measurement for ischaemic myocardium. Myocardial perfusion was then evaluated during reperfusion after release of coronary occlusion. Then the coronary was permanently occluded and 20.5+/-2 channels were drilled with the Holmium:YAG laser and perfusion was measured again. The other four sheep served as control with untreated ischaemia. All animals were sacrificed after 28 days following administration of gadolinium i.v. to serve as contrast medium for magnetic resonance tomography. The hearts were subjected to magnetic resonance tomography and histopathological examination. Intraoperative perfusion measurements revealed a decreased perfusion after temporary occlusion and an increased perfusion in reperfused myocardium. After TMLR, no improvement of myocardial perfusion above the ischaemic level could be shown. Magnetic resonance images could neither confirm patent laser channels nor viable myocardium within ischaemic areas. On histology no patent endocardial laser channel could be detected. The transmural features were myocardial infarct with scar tissue. In the presented sheep model with acute ischaemia, TMLR with a Holmium:YAG laser did not provide acute improvement of myocardial perfusion as assessed by a thermal imaging camera. This would

  17. Dynamic CT myocardial perfusion imaging: performance of 3D semi-automated evaluation software.

    PubMed

    Ebersberger, Ullrich; Marcus, Roy P; Schoepf, U Joseph; Lo, Gladys G; Wang, Yining; Blanke, Philipp; Geyer, Lucas L; Gray, J Cranston; McQuiston, Andrew D; Cho, Young Jun; Scheuering, Michael; Canstein, Christian; Nikolaou, Konstantin; Hoffmann, Ellen; Bamberg, Fabian

    2014-01-01

    To evaluate the performance of three-dimensional semi-automated evaluation software for the assessment of myocardial blood flow (MBF) and blood volume (MBV) at dynamic myocardial perfusion computed tomography (CT). Volume-based software relying on marginal space learning and probabilistic boosting tree-based contour fitting was applied to CT myocardial perfusion imaging data of 37 subjects. In addition, all image data were analysed manually and both approaches were compared with SPECT findings. Study endpoints included time of analysis and conventional measures of diagnostic accuracy. Of 592 analysable segments, 42 showed perfusion defects on SPECT. Average analysis times for the manual and software-based approaches were 49.1 ± 11.2 and 16.5 ± 3.7 min respectively (P < 0.01). There was strong agreement between the two measures of interest (MBF, ICC = 0.91, and MBV, ICC = 0.88, both P < 0.01) and no significant difference in MBF/MBV with respect to diagnostic accuracy between the two approaches for both MBF and MBV for manual versus software-based approach; respectively; all comparisons P > 0.05. Three-dimensional semi-automated evaluation of dynamic myocardial perfusion CT data provides similar measures and diagnostic accuracy to manual evaluation, albeit with substantially reduced analysis times. This capability may aid the integration of this test into clinical workflows. • Myocardial perfusion CT is attractive for comprehensive coronary heart disease assessment. • Traditional image analysis methods are cumbersome and time-consuming. • Automated 3D perfusion software shortens analysis times. • Automated 3D perfusion software increases standardisation of myocardial perfusion CT. • Automated, standardised analysis fosters myocardial perfusion CT integration into clinical practice.

  18. A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism.

    PubMed

    Ko, Toshiyuki; Utanohara, Yuko; Suzuki, Yasuhiro; Kurihara, Makiko; Iguchi, Nobuo; Umemura, Jun; Sumiyoshi, Tetsuya; Tomoike, Hitonobu

    2016-01-01

    Simultaneous dual-isotope SPECT imaging with 201Tl and (123)I-β-methyl-p-iodophenylpentadecanoic acid (BMIPP) is used to study the perfusion-metabolism mismatch. It predicts post-ischemic functional recovery by detecting stunned myocardium. On the other hand, (99m)Tc-MIBI is another radioisotope widely used in myocardial perfusion imaging because of its better image quality and lower radiation exposure than 201Tl. However, since the photopeak energies of (99m)Tc and (123)I are very similar, crosstalk hampers the simultaneous use of these two radioisotopes. To overcome this problem, we conducted simultaneous dual-isotope imaging study using the D-SPECT scanner (Spectrum-Dynamics, Israel) which has a novel detector design and excellent energy resolution. We first conducted a basic experiment using cardiac phantom to simulate the condition of normal perfusion and impaired fatty acid metabolism. Subsequently, we prospectively recruited 30 consecutive patients who underwent successful percutaneous coronary intervention for acute myocardial infarction, and performed (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging within 5 days after reperfusion. Images were interpreted by two experienced cardiovascular radiologists to identify the infarcted and stunned areas based on the coronary artery territories. As a result, cardiac phantom experiment revealed no significant crosstalk between (99m)Tc and (123)I. In the subsequent clinical study, (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging in all participant yielded excellent image quality and detected infarcted and stunned areas correctly when compared with coronary angiographic findings. Furthermore, we were able to reduce radiation exposure to significantly approximately one-eighth. In conclusion, we successfully demonstrated the practical application of simultaneous assessment of myocardial perfusion and fatty acid metabolism by (99m)Tc-MIBI and (123)I-BMIPP using a D-SPECT cardiac scanner. Compared with conventional (201)Tl

  19. Development of an Ex Vivo, Beating Heart Model for CT Myocardial Perfusion

    PubMed Central

    Das, Marco; Haberland, Ulrike; Slump, Cees; Handayani, Astri; van Tuijl, Sjoerd; Stijnen, Marco; Oudkerk, Matthijs; Wildberger, Joachim E.; Vliegenthart, Rozemarijn

    2015-01-01

    Objective. To test the feasibility of a CT-compatible, ex vivo, perfused porcine heart model for myocardial perfusion CT imaging. Methods. One porcine heart was perfused according to Langendorff. Dynamic perfusion scanning was performed with a second-generation dual source CT scanner. Circulatory parameters like blood flow, aortic pressure, and heart rate were monitored throughout the experiment. Stenosis was induced in the circumflex artery, controlled by a fractional flow reserve (FFR) pressure wire. CT-derived myocardial perfusion parameters were analysed at FFR of 1 to 0.10/0.0. Results. CT images did not show major artefacts due to interference of the model setup. The pacemaker-induced heart rhythm was generally stable at 70 beats per minute. During most of the experiment, blood flow was 0.9–1.0 L/min, and arterial pressure varied between 80 and 95 mm/Hg. Blood flow decreased and arterial pressure increased by approximately 10% after inducing a stenosis with FFR ≤ 0.50. Dynamic perfusion scanning was possible across the range of stenosis grades. Perfusion parameters of circumflex-perfused myocardial segments were affected at increasing stenosis grades. Conclusion. An adapted Langendorff porcine heart model is feasible in a CT environment. This model provides control over physiological parameters and may allow in-depth validation of quantitative CT perfusion techniques. PMID:26185756

  20. Improvement of myocardial perfusion in coronary patients after intermittent hypobaric hypoxia.

    PubMed

    del Pilar Valle, Maria; García-Godos, Félix; Woolcott, Orison O; Marticorena, José M; Rodríguez, Víctor; Gutiérrez, Isabel; Fernández-Dávila, Luis; Contreras, Abel; Valdivia, Luis; Robles, Juan; Marticorena, Emilio A

    2006-01-01

    Persons living at high altitude (exposed to hypoxia) have a greater number of coronary and peripheral branches in the heart than persons living at sea level. In this study we investigated the effect of intermittent hypobaric hypoxia on myocardial perfusion in patients with coronary heart disease. We studied 6 male patients (aged>or=53 years) with severe stable coronary heart disease. All patients were born at sea level and lived in that environment. They underwent 14 sessions of exposure to intermittent hypobaric hypoxia (equivalent to a simulated altitude of 4200 m). Myocardial perfusion was assessed at baseline and after treatment with hypoxia by use of exercise perfusion imaging with technetium 99m sestamibi. After the sessions of hypoxia, myocardial perfusion was significantly improved. The summed stress score for hypoperfusion, in arbitrary units, decreased from 9.5+ to 4.5+ after treatment (P=.036). There was no evidence of impairment of myocardial perfusion in any patient after treatment. Intermittent hypobaric hypoxia improved myocardial perfusion in patients with severe coronary heart disease. Though preliminary, our results suggest that exposure to intermittent hypobaric hypoxia could be an alternative for the management of patients with chronic coronary heart disease.

  1. Myocardial Perfusion and Function Are Distinctly Altered by Sevoflurane Anesthesia in Diet-Induced Prediabetic Rats.

    PubMed

    van den Brom, Charissa E; Boly, Chantal A; Bulte, Carolien S E; van den Akker, Rob F P; Kwekkeboom, Rick F J; Loer, Stephan A; Boer, Christa; Bouwman, R Arthur

    2016-01-01

    Preservation of myocardial perfusion during surgery is particularly important in patients with increased risk for perioperative complications, such as diabetes. Volatile anesthetics, like sevoflurane, have cardiodepressive effects and may aggravate cardiovascular complications. We investigated the effect of sevoflurane on myocardial perfusion and function in prediabetic rats. Rats were fed a western diet (WD; n = 18) or control diet (CD; n = 18) for 8 weeks and underwent (contrast) echocardiography to determine perfusion and function during baseline and sevoflurane exposure. Myocardial perfusion was estimated based on the product of microvascular filling velocity and blood volume. WD-feeding resulted in a prediabetic phenotype characterized by obesity, hyperinsulinemia, hyperlipidemia, glucose intolerance, and hyperglycemia. At baseline, WD-feeding impaired myocardial perfusion and systolic function compared to CD-feeding. Exposure of healthy rats to sevoflurane increased the microvascular filling velocity without altering myocardial perfusion but impaired systolic function. In prediabetic rats, sevoflurane did also not affect myocardial perfusion; however, it further impaired systolic function. Diet-induced prediabetes is associated with impaired myocardial perfusion and function in rats. While sevoflurane further impaired systolic function, it did not affect myocardial perfusion in prediabetic rats. Our findings suggest that sevoflurane anesthesia leads to uncoupling of myocardial perfusion and function, irrespective of the metabolic state.

  2. Effects of the repeated administration of adenosine and heparin on myocardial perfusion in patients with chronic stable angina pectoris.

    PubMed

    Barron, H V; Sciammarella, M G; Lenihan, K; Michaels, A D; Botvinick, E H

    2000-01-01

    The mechanism by which ischemia stimulates angiogenesis is unknown. Adenosine is released during myocardial ischemia and may be a mediator of this process. Experimental data suggest that heparin may enhance this effect. The purpose of this open-labeled, placebo-controlled trial was to determine whether repeated intravenous administration of adenosine and heparin could mimic physiologic angiogenesis and reduce the amount of exercise-induced myocardial ischemia in patients with coronary artery disease. Subjects with chronic stable angina refractory to conventional medical therapy and not suitable for revascularization received either adenosine (140 microg/kg/min for 6 minutes) and heparin (10,000 U bolus), (n = 14), or placebo, (n = 7) daily for 10 days. All patients underwent baseline and follow-up exercise testing with thallium-201 single-photon emission computed tomography myocardial perfusion imaging. A semiquantitative assessment of the extent and severity of the perfusion abnormalities was calculated by 2 blinded investigators. There was no significant change in exercise duration or in the peak heart rate systolic blood pressure product associated with adenosine and heparin compared with placebo treatment. There was, however, a 9% reduction in the extent (60.6 +/- 4.0 vs 54.9 +/- 4.1, p = 0.03) and a 14% improvement in severity (41.5 +/- 3.2 vs 35.7 +/- 2.9, p = 0.01) of the myocardial perfusion abnormalities seen in patients who received adenosine and heparin compared with placebo. Thus, in this pilot study, repeated administration of adenosine and heparin reduced the amount of exercise-induced ischemia in patients with chronic stable angina refractory to conventional treatment.

  3. Myocardial Perfusion Pattern for Stratification of Ischemic Mitral Regurgitation Response to Percutaneous Coronary Intervention

    PubMed Central

    Goyal, Parag; Kim, Jiwon; Feher, Attila; Ma, Claudia L.; Gurevich, Sergey; Veal, David R.; Szulc, Massimiliano; Wong, Franklin J.; Ratcliffe, Mark B.; Levine, Robert A.; Devereux, Richard B.; Weinsaft, Jonathan W.

    2015-01-01

    Objective Ischemic mitral regurgitation (MR) is common, but its response to percutaneous coronary intervention (PCI) is poorly understood. This study tested utility of myocardial perfusion imaging (MPI) for stratification of MR response to PCI. Methods MPI and echo were performed among patients undergoing PCI. MPI was used to assess stress/rest myocardial perfusion. MR was assessed via echo (performed pre- and post-PCI). Results 317 patients with abnormal myocardial perfusion on MPI underwent echo 25±39 days prior to PCI. MR was present in 52%, among whom 24% had advanced (≥moderate) MR. MR was associated with LV chamber dilation on MPI and echo (both p<0.001). Magnitude of global LV perfusion deficits increased in relation to MR severity (p<0.01). Perfusion differences were greatest for global summed rest scores, which were 1.6-fold higher among patients with advanced MR vs. those with mild MR (p=0.004), and 2.4-fold higher vs. those without MR (p<0.001). In multivariate analysis, advanced MR was associated with fixed perfusion defect size on MPI (OR 1.16 per segment [CI 1.002–1.34], p=0.046) independent of LV volume (OR 1.10 per 10ml [CI 1.04–1.17], p=0.002). Follow-up via echo (1.0±0.6 years) demonstrated MR to decrease (≥1 grade) in 31% of patients, and increase in 12%. Patients with increased MR after PCI had more severe inferior perfusion defects on baseline MPI (p=0.028), whereas defects in other distributions and LV volumes were similar (p=NS). Conclusions Extent and distribution of SPECT-evidenced myocardial perfusion defects impacts MR response to revascularization. Increased magnitude of inferior fixed perfusion defects predicts post-PCI progression of MR. PMID:26049923

  4. [Assessment of myocardial perfusion and left ventricular function with 99mTc-PPN 1011].

    PubMed

    Kumita, S; Mizumura, S; Oishi, T; Kumazaki, T; Sano, J; Yamazaki, Y; Munakata, K

    1993-04-01

    First-pass radionuclide angiography (FPRNA) was performed with the new myocardial perfusion agent 99mTc-1,2,bis[bis(2-ethoxyethyl)phosphino] ethane (99mTc-PPN 1011) on stress and at rest. One hour after that, myocardial perfusion was counted by 99mTc-PPN 1011 SPECT. Left ventricular ejection fraction (LVEF) obtained by FPRNA correlated with that by multigated image with 99mTc-HSAD (r = 0.94, n = 11). The reduction of left ventricular function under the exercise (delta LVEF) and the increase of severity score (delta Severity score) have a good relation (r = 0.88) in 7 patients with prior myocardial infarction. Thus 99mTc-PPN 1011 appears to be an ideal radiopharmaceutical for evaluation of ventricular function and myocardial perfusion.

  5. Detection of myocardial ischemia by automated, motion-corrected, color-encoded perfusion maps compared with visual analysis of adenosine stress cardiovascular magnetic resonance imaging at 3 T: a pilot study.

    PubMed

    Doesch, Christina; Papavassiliu, Theano; Michaely, Henrik J; Attenberger, Ulrike I; Glielmi, Christopher; Süselbeck, Tim; Fink, Christian; Borggrefe, Martin; Schoenberg, Stefan O

    2013-09-01

    The purpose of this study was to compare automated, motion-corrected, color-encoded (AMC) perfusion maps with qualitative visual analysis of adenosine stress cardiovascular magnetic resonance imaging for detection of flow-limiting stenoses. Myocardial perfusion measurements applying the standard adenosine stress imaging protocol and a saturation-recovery temporal generalized autocalibrating partially parallel acquisition (t-GRAPPA) turbo fast low angle shot (Turbo FLASH) magnetic resonance imaging sequence were performed in 25 patients using a 3.0-T MAGNETOM Skyra (Siemens Healthcare Sector, Erlangen, Germany). Perfusion studies were analyzed using AMC perfusion maps and qualitative visual analysis. Angiographically detected coronary artery (CA) stenoses greater than 75% or 50% or more with a myocardial perfusion reserve index less than 1.5 were considered as hemodynamically relevant. Diagnostic performance and time requirement for both methods were compared. Interobserver and intraobserver reliability were also assessed. A total of 29 CA stenoses were included in the analysis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for detection of ischemia on a per-patient basis were comparable using the AMC perfusion maps compared to visual analysis. On a per-CA territory basis, the attribution of an ischemia to the respective vessel was facilitated using the AMC perfusion maps. Interobserver and intraobserver reliability were better for the AMC perfusion maps (concordance correlation coefficient, 0.94 and 0.93, respectively) compared to visual analysis (concordance correlation coefficient, 0.73 and 0.79, respectively). In addition, in comparison to visual analysis, the AMC perfusion maps were able to significantly reduce analysis time from 7.7 (3.1) to 3.2 (1.9) minutes (P < 0.0001). The AMC perfusion maps yielded a diagnostic performance on a per-patient and on a per-CA territory basis comparable with the visual analysis

  6. Prognostic value of high-dose dobutamine stress magnetic resonance imaging in 1,493 consecutive patients: assessment of myocardial wall motion and perfusion.

    PubMed

    Korosoglou, Grigorios; Elhmidi, Yacine; Steen, Henning; Schellberg, Dieter; Riedle, Nina; Ahrens, Johannes; Lehrke, Stephanie; Merten, Constanze; Lossnitzer, Dirk; Radeleff, Jannis; Zugck, Christian; Giannitsis, Evangelos; Katus, Hugo A

    2010-10-05

    This study sought to determine the prognostic value of wall motion and perfusion assessment during high-dose dobutamine stress (DS) cardiac magnetic resonance imaging (MRI) in a large patient cohort. DS-MRI offers the possibility to integrate myocardial perfusion and wall motion analysis in a single examination for the detection of coronary artery disease (CAD). A total of 1,493 consecutive patients with suspected or known CAD underwent DS-MRI, using a standard protocol in a 1.5-T magnetic resonance scanner. Wall motion and perfusion were assessed at baseline and during stress, and outcome data including cardiac death, nonfatal myocardial infarction ("hard events"), and "late" revascularization performed >90 days after the MR scans were collected during a 2 ± 1 year follow-up period. Fifty-three hard events, including 14 cardiac deaths and 39 nonfatal infarctions, occurred during the follow-up period, whereas 85 patients underwent "late" revascularization. Using multivariable regression analysis, an abnormal result for wall motion or perfusion during stress yielded the strongest independent prognostic value for both hard events and late revascularization, clearly surpassing that of clinical and baseline magnetic resonance parameters (for wall motion: adjusted hazard ratio [HR] of 5.9 [95% confidence interval (CI): 2.5 to 13.6] for hard events and of 3.1 [95% CI: 1.7 to 5.6] for late revascularization, and for perfusion: adjusted HR of 5.4 [95% CI: 2.3 to 12.9] for hard events and of 6.2 [95% CI: 3.3 to 11.3] for late revascularization, p < 0.001 for all). DS-MRI can accurately identify patients who are at increased risk for cardiac death and myocardial infarction, separating them from those with normal findings, who have very low risk for future cardiac events. (Prognostic Value of High Dose Dobutamine Stress Magnetic Resonance Imaging; NCT00837005). Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Fractional flow reserve and myocardial viability as assessed by SPECT perfusion scintigraphy in patients with prior myocardial infarction.

    PubMed

    Beleslin, Branko; Dobric, Milan; Sobic-Saranovic, Dragana; Giga, Vojislav; Stepanovic, Jelena; Djordjevic-Dikic, Ana; Nedeljkovic, Milan; Stojkovic, Sinisa; Vukcevic, Vladan; Stankovic, Goran; Orlic, Dejan; Petrasinovic, Zorica; Pavlovic, Smiljana; Obradovic, Vladimir; Ostojic, Miodrag

    2010-10-01

    In patients with previous myocardial infarction (MI), assessment of myocardial viability and physiological significance of coronary artery stenoses are essential for appropriate guidance of revascularization. The aim of the study was to evaluate the relation between fractional flow reserve (FFR) and myocardial viability as assessed by gated SPECT MIBI perfusion scintigraphy in patients with previous MI undergoing elective PCI. The study population consisted of 26 patients (mean age 55 ± 7 years; 21 male) with a previous MI and a significant coronary stenosis in a single infarct-related coronary vessel for which PCI was being performed. In all patients, FFR was evaluated before and immediately after PCI. SPECT imaging was done before and 3 ± 1 months after PCI. A region representing the MI was considered viable if MIBI uptake was ≥55% of the normal region. Improvement in perfusion after revascularization was considered achieved if perfusion abnormalities decreased by 5% or more and there was a decrease in segmental score of ≥1 in three segments in PCI-related vascular territory. Extent of perfusion abnormalities decreased from 32 ± 16% to 27 ± 19% after PCI (P < .001). In patients with myocardial viability in comparison to patients with no viability, there was significant difference in FFR before PCI (.57 ± .14 vs .76 ± .12, P = .002), despite almost the same values of diameter stenosis of infarct-related artery (63 ± 8% vs 64 ± 3%, respectively, P = .572). In addition, FFR prior to PCI was related to improvement in perfusion abnormalities after revascularization (P = .047), as well as with peak activity of creatine-kinase measured during previous MI (r = .56, P = .005). Lower values of FFR before angioplasty are associated with myocardial viability and functional improvement as assessed by SPECT perfusion scintigraphy.

  8. One-year follow-up of myocardial perfusion and function evaluated by gated SPECT MIBI in patients with earlier myocardial infarction and chronic total occlusion.

    PubMed

    Pavlovic, Smiljana V; Sobic-Saranovic, Dragana P; Beleslin, Branko D; Ostojic, Miodrag C; Nedeljkovic, Milan A; Giga, Vojislav L; Petrasinovic, Zorica R; Artiko, Vera M; Todorovic-Tirnanic, Mila V; Obradovic, Vladimir B

    2009-01-01

    Optimal treatment for chronic total occlusion (CTO) in the infarct-related coronary artery is not clear. Our aim was to assess myocardial perfusion, left ventricular ejection fraction (EF), and left ventricular size using gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging with 99mTc-methoxy-isobutyl-isonitrile in patients with CTO before and 1 year after recanalization. Thirty patients with earlier myocardial infarction and at least one CTO underwent percutaneous coronary intervention (PCI) as well as nitrate-enhanced gated SPECT myocardial perfusion and dobutamine stress echocardiography before and 11 +/- 1 months after recanalization. They were divided into three groups based on the outcome of the follow-up angiography: (i) successful recanalization with no evidence of in-stent restenosis (n=13); (ii) successful recanalization with in-stent restenosis (n=7) and (iii) unsuccessful recanalization (n=10). Overall success of recanalization for CTO was 74%. In group 1, myocardial viability was preserved in 11 of 13 (85%) patients at baseline. Gated SPECT at 1 year showed a significant decrease in perfusion abnormalities (29 +/- 12 to 23 +/- 14%, P < 0.05) and left ventricular end-diastolic volume (EDV) (168 +/- 47 to 151 +/- 47 ml, P < 0.05). Improvement in EF (51 +/- 11 to 54 +/- 13%, P > 0.05) and reduction in left ventricular end-systolic volume (ESV) (84 +/- 37 to 77 +/- 40 ml, P > 0.05) did not reach the level of significance. Myocardial viability was preserved in only two of seven patients (28%) in group 2. Neither mean perfusion abnormalities (37 +/- 24 to 35 +/- 22%, P > 0.05) nor global left ventricular parameters (EF 41 +/- 15 vs. 42 +/- 19%, EDV 298 +/- 33 vs. 299 +/- 57 mL, ESV 197 +/- 12 vs. 195 +/- 32 ml; P > 0.05) changed at the follow-up. In group 3, myocardial viability was preserved in seven of 10 patients (70%) at baseline, but no significant changes in perfusion (40 +/- 18 vs. 41 +/- 19%, P > 0.05) and left

  9. Budget impact of applying appropriateness criteria for myocardial perfusion scintigraphy: The perspective of a developing country.

    PubMed

    Dos Santos, Mauro Augusto; Santos, Marisa Silva; Tura, Bernardo Rangel; Félix, Renata; Brito, Adriana Soares X; De Lorenzo, Andrea

    2016-10-01

    Myocardial perfusion imaging is widely used for the risk stratification of coronary artery disease. In view of its cost, besides radiation issues, judicious evaluation of the appropriateness of its indications is essential to prevent an unnecessary economic burden on the health system. We evaluated, at a tertiary-care, public Brazilian hospital, the appropriateness of myocardial perfusion scintigraphy indications, and estimated the budget impact of applying appropriateness criteria. An observational, cross-sectional study of 190 patients with suspected or known coronary artery disease referred for myocardial perfusion imaging was conducted. The appropriateness of myocardial perfusion imaging indications was evaluated with the Appropriate Use Criteria for Cardiac Radionuclide Imaging published in 2009. Budget impact analysis was performed with a deterministic model. The prevalence of appropriate requests was 78%; of inappropriate indications, 12%; and of uncertain indications, 10%. Budget impact analysis showed that the use of appropriateness criteria, applied to the population referred to myocardial perfusion scintigraphy within 1 year, could generate savings of $ 64,252.04 dollars. The 12% inappropriate requests for myocardial perfusion scintigraphy at a tertiary-care hospital suggest that a reappraisal of MPI indications is needed. Budget impact analysis estimated resource savings of 18.6% with the establishment of appropriateness criteria for MPI.

  10. 3D perfusion mapping in the intact mouse heart after myocardial infarction using myocardial contrast echocardiography

    NASA Astrophysics Data System (ADS)

    Li, Yinbo; Yang, Zequan; French, Brent A.; Hossack, John A.

    2005-04-01

    An intact mouse model of surgically-induced myocardial infarction (MI) caused by permanent occlusion of the Left Anterior Descending (LAD) coronary artery was studied. Normal mice with no occlusion were also studied as controls. For each mouse, contrast enhanced ultrasound images of the heart were acquired in parallel cross-sections perpendicular to the sternum at millimeter increments. For accurate 3D reconstruction, ECG gating and a tri-axial adjustable micromanipulator were used for temporal and spatial registration. Ultrasound images at steady-state of blood refilling were color-coded in each slice to show relative perfusion. Myocardial perfusion defects and necrosis were also examined postmortem by staining with Phthalo blue and TTC red dyes. Good correlation (R>0.93) in perfused area size was observed between in vivo measurements and histological staining. A 3D multi-slice model and a 3D rendering of perfusion distribution were created and showed a promising match with postmortem results, lending further credence to its use as a more comprehensive and more reliable tool for in vivo assessment of myocardial perfusion than 2D tomographic analysis.

  11. Selective Cerebro-Myocardial Perfusion in Complex Neonatal Aortic Arch Pathology: Midterm Results.

    PubMed

    Hoxha, Stiljan; Abbasciano, Riccardo Giuseppe; Sandrini, Camilla; Rossetti, Lucia; Menon, Tiziano; Barozzi, Luca; Linardi, Daniele; Rungatscher, Alessio; Faggian, Giuseppe; Luciani, Giovanni Battista

    2018-04-01

    Aortic arch repair in newborns and infants has traditionally been accomplished using a period of deep hypothermic circulatory arrest. To reduce neurologic and cardiac dysfunction related to circulatory arrest and myocardial ischemia during complex aortic arch surgery, an alternative and novel strategy for cerebro-myocardial protection was recently developed, where regional low-flow perfusion is combined with controlled and independent coronary perfusion. The aim of the present retrospective study was to assess short-term and mid-term results of selective and independent cerebro-myocardial perfusion in neonatal aortic arch surgery. From April 2008 to August 2015, 28 consecutive neonates underwent aortic arch surgery under cerebro-myocardial perfusion. There were 17 male and 11 female, with median age of 15 days (3-30 days) and median body weight of 3 kg (1.6-4.2 kg), 9 (32%) of whom with low body weight (<2.5 kg). The spectrum of pathologies treated was heterogeneous and included 13 neonates having single-stage biventricular repair (46%), 7 staged biventricular repair (25%), and 8 single-ventricle repair (29%). All operations were performed under moderate hypothermia and with a "beating heart and brain." Average cardiopulmonary bypass time was 131 ± 64 min (42-310 min). A period of cardiac arrest to complete intra-cardiac repair was required in nine patients (32%), and circulatory arrest in 1 to repair total anomalous pulmonary venous connection. Average time of splanchnic ischemia during cerebro-myocardial perfusion was 30 ± 11 min (15-69 min). Renal dysfunction, requiring a period of peritoneal dialysis was observed in 10 (36%) patients, while liver dysfunction was noted only in 3 (11%). There were three (11%) early and two late deaths during a median follow-up of 2.9 years (range 6 months-7.7 years), with an actuarial survival of 82% at 7 years. At latest follow-up, no patient showed signs of cardiac or neurologic dysfunction. The present experience

  12. T1-201 chloride scintigraphy for bone tumors and soft part sarcomas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terui, S.; Oyamada, H.; Nishikawa, K.

    1984-01-01

    The author investigated T1-201 chloride as a tumor scanning agent of both tumors and soft part sarcomas. Six bone tumors (2 with Ewing sarcoma, 3 with osteosarcoma and 1 with giant cell tumor) and 3 soft part sarcoma (1 with liposarcoma and 2 with malignant fibrous histiocytoma (MFH)) were examined. All but one MFH were untreated primary cases. The diagnosis was determined from biopsy specimen. One patient with Ewing sarcoma had bone metastases. All cases were subsequently received chemotherpeutic agents. Surgery or local irradiation were also used in treatment. T1-201 scintigraphy were performed with intravenous administration of 2 mCi ofmore » T1-201 chloride before initiation of therapy. In addition, follow-up examinations were done in 4 patients (2 with Ewing sarcoma and 2 with osteosarcoma) to study the effect of chemotherapy on T1-201 uptake by the tumor. Tc-99m bone scans were available for comparison in 6 tumor. Ga-67 citrate scans were also examined for the 3 soft part sarcomas. The untreated tumors even in the metastatic lesions of Ewing sarcoma were distinctly visualized with T1-201 in all cases. The distribution of T1-201 in the tumors was sometimes different from that of Tc-99m and similar to that of Ga-67. Of 3 out of the 4 follow-up patients, the post-therapy scan showed reduction in T1-201 uptake more markedly than Tc-99m uptake during effective chemotherapy. The other one patient had not responded to the treatment so that the scan showed no changes in T1-201 uptake. These findings indicate that the tumor imaging with T1-201 is useful in the diagnosis of these malignant tumors and may be of value in assessing the response of bone tumors to chemotherapy.« less

  13. Hyperemic stress myocardial perfusion cardiovascular magnetic resonance in mice at 3 Tesla: initial experience and validation against microspheres.

    PubMed

    Jogiya, Roy; Makowski, Markus; Phinikaridou, Alkystsis; Patel, Ashish S; Jansen, Christian; Zarinabad, Niloufar; Chiribiri, Amedeo; Botnar, Rene; Nagel, Eike; Kozerke, Sebastian; Plein, Sven

    2013-07-21

    Dynamic first pass contrast-enhanced myocardial perfusion is the standard CMR method for the estimation of myocardial blood flow (MBF) and MBF reserve in man, but it is challenging in rodents because of the high temporal and spatial resolution requirements. Hyperemic first pass myocardial perfusion CMR during vasodilator stress in mice has not been reported. Five C57BL/6 J mice were scanned on a clinical 3.0 Tesla Achieva system (Philips Healthcare, Netherlands). Vasodilator stress was induced via a tail vein catheter with an injection of dipyridamole. Dynamic contrast-enhanced perfusion imaging (Gadobutrol 0.1 mmol/kg) was based on a saturation recovery spoiled gradient echo method with 10-fold k-space and time domain undersampling (k-t PCA). One week later the mice underwent repeat anaesthesia and LV injections of fluorescent microspheres at rest and at stress. Microspheres were analysed using confocal microscopy and fluorescence-activated cell sorting. Mean MBF at rest measured by Fermi-function constrained deconvolution was 4.1 ± 0.5 ml/g/min and increased to 9.6 ± 2.5 ml/g/min during dipyridamole stress (P = 0.005). The myocardial perfusion reserve was 2.4 ± 0.54. The mean count ratio of stress to rest microspheres was 2.4 ± 0.51 using confocal microscopy and 2.6 ± 0.46 using fluorescence. There was good agreement between cardiovascular magnetic resonance CMR and microspheres with no significant difference (P = 0.84). First-pass myocardial stress perfusion CMR in a mouse model is feasible at 3 Tesla. Rest and stress MBF values were consistent with existing literature and perfusion reserve correlated closely to microsphere analysis. Data were acquired on a 3 Tesla scanner using an approach similar to clinical acquisition protocols, potentially facilitating translation of imaging findings between rodent and human studies.

  14. Thallium-201 scintigraphy in the diagnosis and management of myocardial sarcoidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fields, C.L.; Ossorio, M.A.; Roy, T.M.

    1990-03-01

    We have described three patients with clinical evidence of myocardial sarcoidosis to illustrate the utility of thallium-201 scintigraphy in demonstrating the myocardial lesions. Both the symptomatic and asymptomatic individuals studied showed the characteristic reverse redistribution phenomenon. No abnormalities were seen during the exercise phase of the thallium study, but myocardial defects were detected in each patient when repeat studies were obtained at rest six hours later. Steroid therapy resolved the defects in each case. We propose thallium-201 scintigraphy of the heart as a safe and useful tool for documenting myocardial involvement in sarcoidosis and following the effects of therapy.

  15. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols.

    PubMed

    Verger, Antoine; Djaballah, Wassila; Fourquet, Nicolas; Rouzet, François; Koehl, Grégoire; Imbert, Laetitia; Poussier, Sylvain; Fay, Renaud; Roch, Véronique; Le Guludec, Dominique; Karcher, Gilles; Marie, Pierre-Yves

    2013-02-01

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving (201)Tl (n = 120) or (99m)Tc-sestamibi injected at low dose at stress ((99m)Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ((99m)Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, (201)Tl 92 %, (99m)Tc-Low 86 %, (99m)Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p < 0.001). This larger extent was mainly observed in 50 obese patients who were in the (201)Tl or (99m)Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 ± 101 kcounts) and dramatically enhanced with CZT SPECT (+279 ± 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT.

  16. Geographic and demographic variabilities of quantitative parameters in stress myocardial computed tomography perfusion.

    PubMed

    Park, Jinoh; Kim, Hyun-Sook; Hwang, Hye Jeon; Yang, Dong Hyun; Koo, Hyun Jung; Kang, Joon-Won; Kim, Young-Hak

    2017-09-01

    To evaluate the geographic and demographic variabilities of the quantitative parameters of computed tomography perfusion (CTP) of the left ventricular (LV) myocardium in patients with normal coronary artery on computed tomography angiography (CTA). From a multicenter CTP registry of stress and static computed tomography, we retrospectively recruited 113 patients (mean age, 60 years; 57 men) without perfusion defect on visual assessment and minimal (< 20% of diameter stenosis) or no coronary artery disease on CTA. Using semiautomatic analysis software, quantitative parameters of the LV myocardium, including the myocardial attenuation in stress and rest phases, transmural perfusion ratio (TPR), and myocardial perfusion reserve index (MPRI), were evaluated in 16 myocardial segments. In the lateral wall of the LV myocardium, all quantitative parameters except for MPRI were significantly higher compared with those in the other walls. The MPRI showed consistent values in all myocardial walls (anterior to lateral wall: range, 25% to 27%; p = 0.401). At the basal level of the myocardium, all quantitative parameters were significantly lower than those at the mid- and apical levels. Compared with men, women had significantly higher values of myocardial attenuation and TPR. Age, body mass index, and Framingham risk score were significantly associated with the difference in myocardial attenuation. Geographic and demographic variabilities of quantitative parameters in stress myocardial CTP exist in healthy subjects without significant coronary artery disease. This information may be helpful when assessing myocardial perfusion defects in CTP.

  17. Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT.

    PubMed

    Ghaly, Michael; Links, Jonathan M; Frey, Eric C

    2015-07-07

    Dual-isotope simultaneous-acquisition (DISA) rest-stress myocardial perfusion SPECT (MPS) protocols offer a number of advantages over separate acquisition. However, crosstalk contamination due to scatter in the patient and interactions in the collimator degrade image quality. Compensation can reduce the effects of crosstalk, but does not entirely eliminate image degradations. Optimizing acquisition parameters could further reduce the impact of crosstalk. In this paper we investigate the optimization of the rest Tl-201 energy window width and relative injected activities using the ideal observer (IO), a realistic digital phantom population and Monte Carlo (MC) simulated Tc-99m and Tl-201 projections as a means to improve image quality. We compared performance on a perfusion defect detection task for Tl-201 acquisition energy window widths varying from 4 to 40 keV centered at 72 keV for a camera with a 9% energy resolution. We also investigated 7 different relative injected activities, defined as the ratio of Tc-99m and Tl-201 activities, while keeping the total effective dose constant at 13.5 mSv. For each energy window and relative injected activity, we computed the IO test statistics using a Markov chain Monte Carlo (MCMC) method for an ensemble of 1,620 triplets of fixed and reversible defect-present, and defect-absent noisy images modeling realistic background variations. The volume under the 3-class receiver operating characteristic (ROC) surface (VUS) was estimated and served as the figure of merit. For simultaneous acquisition, the IO suggested that relative Tc-to-Tl injected activity ratios of 2.6-5 and acquisition energy window widths of 16-22% were optimal. For separate acquisition, we observed a broad range of optimal relative injected activities from 2.6 to 12.1 and acquisition energy window of widths 16-22%. A negative correlation between Tl-201 injected activity and the width of the Tl-201 energy window was observed in these ranges. The results

  18. Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT

    PubMed Central

    Ghaly, Michael; Links, Jonathan M; Frey, Eric C

    2015-01-01

    Dual-isotope simultaneous-acquisition (DISA) rest-stress myocardial perfusion SPECT (MPS) protocols offer a number of advantages over separate acquisition. However, crosstalk contamination due to scatter in the patient and interactions in the collimator degrade image quality. Compensation can reduce the effects of crosstalk, but does not entirely eliminate image degradations. Optimizing acquisition parameters could further reduce the impact of crosstalk. In this paper we investigate the optimization of the rest Tl-201 energy window width and relative injected activities using the ideal observer (IO), a realistic digital phantom population and Monte Carlo (MC) simulated Tc-99m and Tl-201 projections as a means to improve image quality. We compared performance on a perfusion defect detection task for Tl-201 acquisition energy window widths varying from 4 to 40 keV centered at 72 keV for a camera with a 9% energy resolution. We also investigated 7 different relative injected activities, defined as the ratio of Tc-99m and Tl-201 activities, while keeping the total effective dose constant at 13.5 mSv. For each energy window and relative injected activity, we computed the IO test statistics using a Markov chain Monte Carlo (MCMC) method for an ensemble of 1,620 triplets of fixed and reversible defect-present, and defect-absent noisy images modeling realistic background variations. The volume under the 3-class receiver operating characteristic (ROC) surface (VUS) was estimated and served as the figure of merit. For simultaneous acquisition, the IO suggested that relative Tc-to-Tl injected activity ratios of 2.6–5 and acquisition energy window widths of 16–22% were optimal. For separate acquisition, we observed a broad range of optimal relative injected activities from 2.6 to 12.1 and acquisition energy window of widths 16–22%. A negative correlation between Tl-201 injected activity and the width of the Tl-201 energy window was observed in these ranges. The results

  19. Influence of angiographic collateral circulation on myocardial perfusion in patients with chronic total occlusion of a single coronary artery and no prior myocardial infarction.

    PubMed

    Aboul-Enein, Fatma; Kar, Saibal; Hayes, Sean W; Sciammarella, Maria; Abidov, Aiden; Makkar, Raj; Friedman, John D; Eigler, Neal; Berman, Daniel S

    2004-06-01

    The functional role of various angiographic grades for coronary collaterals remains controversial. The aim of this study was to assess the influence of the Rentrop angiographic grading of coronary collaterals on myocardial perfusion in patients with single-vessel chronic total occlusion (CTO) and no prior myocardial infarction (MI). The study included 56 patients with single-vessel CTO and no prior MI who underwent rest-stress myocardial perfusion SPECT and coronary angiography within 6 mo. All patients had angiographic evidence of coronary collaterals. Patients were divided according to the Rentrop classification: Group I had grade 1 or 2 (n = 25) and group II had grade 3 collaterals (n = 31). Group I had a higher frequency of resting regional wall motion abnormalities on left ventriculography (52.6% vs. 19.2% [P = 0.019]). The mean perfusion scores of the overall population showed severe and extensive stress perfusion defects (summed stress score of 14.1 +/- 7.1 and summed difference score of 12.9 +/- 6.9) but minimal resting perfusion defects (summed rest score of 1.0 +/- 2.7). No perfusion scores differed between the 2 groups. The perfusion findings suggested that chronic stunning rather than hibernation is the principal cause of regional wall motion abnormalities in these patients. In the setting of single-vessel CTO and no prior MI, coronary collaterals appear to protect against resting perfusion defects. Excellent angiographic collaterals may prevent resting regional wall motion abnormalities but do not appear to protect against stress-induced perfusion defects.

  20. Automated quantification of myocardial perfusion SPECT using simplified normal limits.

    PubMed

    Slomka, Piotr J; Nishina, Hidetaka; Berman, Daniel S; Akincioglu, Cigdem; Abidov, Aiden; Friedman, John D; Hayes, Sean W; Germano, Guido

    2005-01-01

    To simplify development of normal limits for myocardial perfusion SPECT (MPS), we implemented a quantification scheme in which normal limits are derived without visual scoring of abnormal scans or optimization of regional thresholds. Normal limits were derived from same-day TI-201 rest/Tc-99m-sestamibi stress scans of male (n = 40) and female (n = 40) low-likelihood patients. Defect extent, total perfusion deficit (TPD), and regional perfusion extents were derived by comparison to normal limits in polar-map coordinates. MPS scans from 256 consecutive patients without known coronary artery disease, who underwent coronary angiography, were analyzed. The new method of quantification (TPD) was compared with our previously developed quantification system and visual scoring. The receiver operator characteristic area under the curve for detection of 50% or greater stenoses by TPD (0.88 +/- 0.02) was higher than by visual scoring (0.83 +/- 0.03) ( P = .039) or standard quantification (0.82 +/- 0.03) ( P = .004). For detection of 70% or greater stenoses, it was higher for TPD (0.89 +/- 0.02) than for standard quantification (0.85 +/- 0.02) ( P = .014). Sensitivity and specificity were 93% and 79%, respectively, for TPD; 81% and 85%, respectively, for visual scoring; and 80% and 73%, respectively, for standard quantification. The use of stress mode-specific normal limits did not improve performance. Simplified quantification achieves performance better than or equivalent to visual scoring or quantification based on per-segment visual optimization of abnormality thresholds.

  1. Normal Databases for the Relative Quantification of Myocardial Perfusion

    PubMed Central

    Rubeaux, Mathieu; Xu, Yuan; Germano, Guido; Berman, Daniel S.; Slomka, Piotr J.

    2016-01-01

    Purpose of review Myocardial perfusion imaging (MPI) with SPECT is performed clinically worldwide to detect and monitor coronary artery disease (CAD). MPI allows an objective quantification of myocardial perfusion at stress and rest. This established technique relies on normal databases to compare patient scans against reference normal limits. In this review, we aim to introduce the process of MPI quantification with normal databases and describe the associated perfusion quantitative measures that are used. Recent findings New equipment and new software reconstruction algorithms have been introduced which require the development of new normal limits. The appearance and regional count variations of normal MPI scan may differ between these new scanners and standard Anger cameras. Therefore, these new systems may require the determination of new normal limits to achieve optimal accuracy in relative myocardial perfusion quantification. Accurate diagnostic and prognostic results rivaling those obtained by expert readers can be obtained by this widely used technique. Summary Throughout this review, we emphasize the importance of the different normal databases and the need for specific databases relative to distinct imaging procedures. use of appropriate normal limits allows optimal quantification of MPI by taking into account subtle image differences due to the hardware and software used, and the population studied. PMID:28138354

  2. [Performance of Thallium 201 rest-redistribution spect to predict viability in recent myocardial infarction].

    PubMed

    Coll, Claudia; González, Patricio; Massardo, Teresa; Sierralta, Paulina; Humeres, Pamela; Jofré, Josefina; Yovanovich, Jorge; Aramburú, Ivonne; Brugère, Solange; Chamorro, Hernán; Ramírez, Alfredo; Kunstmann, Sonia; López, Héctor

    2002-03-01

    The detection of viability after acute myocardial infarction is primordial to select the most appropriate therapy, to decrease cardiac events and abnormal remodeling. Thallium201 SPECT is one of the radionuclide techniques used to detect viability. To evaluate the use of Thallium201 rest-redistribution SPECT to detect myocardial viability in reperfused patients after a recent myocardial infarction. Forty one patients with up to of 24 days of evolution of a myocardial infarction were studied. All had angiographically demonstrated coronary artery disease and were subjected to a successful thrombolysis, angioplasty or bypass grafting. SPECT Thallium201 images were acquired at rest and after 4 h of redistribution. These results were compared with variations in wall motion score, studied at baseline and after 3 or 4 months with echocardiography. The sensitivity of rest-redistribution Thallium201 SPECT, to predict recovery of wall motion was 91% when patient analysis was performed and 79% when segmental analysis was done in the culprit region. The figures for specificity were 56 and 73% respectively. Rest-distribution Thallium201 SPECT has an excellent sensitivity to predict myocardial viability in recent myocardial infarction. The data obtained in this study is similar to that reported for chronic coronary artery disease.

  3. Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera.

    PubMed

    Ben-Haim, Simona; Kacperski, Krzysztof; Hain, Sharon; Van Gramberg, Dean; Hutton, Brian F; Erlandsson, Kjell; Sharir, Tali; Roth, Nathaniel; Waddington, Wendy A; Berman, Daniel S; Ell, Peter J

    2010-08-01

    We compared simultaneous dual-radionuclide (DR) stress and rest myocardial perfusion imaging (MPI) with a novel solid-state cardiac camera and a conventional SPECT camera with separate stress and rest acquisitions. Of 27 consecutive patients recruited, 24 (64.5+/-11.8 years of age, 16 men) were injected with 74 MBq of (201)Tl (rest) and 250 MBq (99m)Tc-MIBI (stress). Conventional MPI acquisition times for stress and rest are 21 min and 16 min, respectively. Rest (201)Tl for 6 min and simultaneous DR 15-min list mode gated scans were performed on a D-SPECT cardiac scanner. In 11 patients DR D-SPECT was performed first and in 13 patients conventional stress (99m)Tc-MIBI SPECT imaging was performed followed by DR D-SPECT. The DR D-SPECT data were processed using a spill-over and scatter correction method. DR D-SPECT images were compared with rest (201)Tl D-SPECT and with conventional SPECT images by visual analysis employing the 17-segment model and a five-point scale (0 normal, 4 absent) to calculate the summed stress and rest scores. Image quality was assessed on a four-point scale (1 poor, 4 very good) and gut activity was assessed on a four-point scale (0 none, 3 high). Conventional MPI studies were abnormal at stress in 17 patients and at rest in 9 patients. In the 17 abnormal stress studies DR D-SPECT MPI showed 113 abnormal segments and conventional MPI showed 93 abnormal segments. In the nine abnormal rest studies DR D-SPECT showed 45 abnormal segments and conventional MPI showed 48 abnormal segments. The summed stress and rest scores on conventional SPECT and DR D-SPECT were highly correlated (r=0.9790 and 0.9694, respectively). The summed scores of rest (201)Tl D-SPECT and DR-DSPECT were also highly correlated (r=0.9968, p<0.0001 for all). In six patients stress perfusion defects were significantly larger on stress DR D-SPECT images, and five of these patients were imaged earlier by D-SPECT than by conventional SPECT. Fast and high-quality simultaneous DR

  4. Selective cerebro-myocardial perfusion in complex congenital aortic arch pathology: a novel technique.

    PubMed

    De Rita, Fabrizio; Lucchese, Gianluca; Barozzi, Luca; Menon, Tiziano; Faggian, Giuseppe; Mazzucco, Alessandro; Luciani, Giovanni Battista

    2011-11-01

    Simultaneous cerebro-myocardial perfusion has been described in neonatal and infant arch surgery, suggesting a reduction in cardiac morbidity. Here reported is a novel technique for selective cerebral perfusion combined with controlled and independent myocardial perfusion during surgery for complex or recurrent aortic arch lesions. From April 2008 to April 2011, 10 patients with arch pathology underwent surgery (two hypoplastic left heart syndrome [HLHS], four recurrent arch obstruction, two aortic arch hypoplasia + ventricular septal defect [VSD], one single ventricle + transposition of the great arteries + arch hypoplasia, one interrupted aortic arch type B + VSD). Median age was 63 days (6 days-36 years) and median weight 4.0 kg (1.6-52). Via midline sternotomy, an arterial cannula (6 or 8 Fr for infants) was directly inserted into the innominate artery or through a polytetrafluoroethylene (PTFE) graft (for neonates <2.0 kg). A cardioplegia delivery system was inserted into the aortic root. Under moderate hypothermia, ascending and descending aorta were cross-clamped, and "beating heart and brain" aortic arch repair was performed. Arch repair was composed of patch augmentation in five, end-to-side anastomosis in three, and replacement in two patients. Average cardiopulmonary bypass time was 163 ± 68 min (71-310). In two patients only (one HLHS, one complex single ventricle), a period of cardiac arrest was required to complete intracardiac repair. In such cases, antegrade blood cardioplegia was delivered directly via the same catheter used for selective myocardial perfusion. Average time of splanchnic ischemia during cerebro-myocardial perfusion was 39 ± 18 min (17-69). Weaning from cardiopulmonary bypass was achieved without inotropic support in three and with low dose in seven patients. One patient required veno-arterial extracorporeal membrane oxygenation. Four patients, body weight <3.0 kg, needed delayed sternal closure. No neurologic dysfunction was noted

  5. Detecting Myocardial Ischemia With 99mTechnetium-Tetrofosmin Myocardial Perfusion Imaging in Ischemic Stroke.

    PubMed

    Giannopoulos, Sotirios; Markoula, Sofia; Sioka, Chrissa; Zouroudi, Sofia; Spiliotopoulou, Maria; Naka, Katerina K; Michalis, Lampros K; Fotopoulos, Andreas; Kyritsis, Athanassios P

    2017-10-01

    To assess the myocardial status in patients with stroke, employing myocardial perfusion imaging (MPI) with 99m Technetium-tetrofosmin ( 99m Tc-TF)-single-photon emission computed tomography (SPECT). Fifty-two patients with ischemic stroke were subjected to 99m Tc-TF-SPECT MPI within 1 month after stroke occurrence. None of the patients had any history or symptoms of coronary artery disease or other heart disease. Myocardial perfusion imaging was evaluated visually using a 17-segment polar map. Myocardial ischemia (MIS) was defined as present when the summed stress score (SSS) was >4; MIS was defined as mild when SSS was 4 to 8, and moderate/severe with SSS ≥9. Patients with SSS >4 were compared to patients with SSS <4. Parameters such as age, body mass index, waist perimeter, smoking habits, and medical history (diabetes mellitus, dyslipidemia, etc) were evaluated according to MPI results. Myocardial ischemia was present in 32 (62%) of 52 patients with stroke. Among them, 20 (62%) of 32 patients had mild abnormalities and 12 (38%) of 32 had moderate/severe. The age and waist perimeter showed a tendency to relate to severe MIS when patients with SSS >9 were compared to patients with SSS <4. In MPI-positive patients, an age was to be association with SSS, with the oldest age exhibiting the highest SSS ( P = .01). The association of age with SSS remained statistically significant in the multivariate analysis ( P = .04). The study suggested that more than half of patients with stroke without a history of cardiac disease have MIS. Although most of them have mild MIS, we suggest a thorough cardiological evaluation in this group of patients for future prevention of severe myocardial outcome.

  6. Contrast-enhanced 3T MR Perfusion of Musculoskeletal Tumours: T1 Value Heterogeneity Assessment and Evaluation of the Influence of T1 Estimation Methods on Quantitative Parameters.

    PubMed

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Chen, Bailiang; De Verbizier, Jacques; Beaumont, Marine; Badr, Sammy; Cotten, Anne; Blum, Alain

    2017-12-01

    To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. • T1 value variation in musculoskeletal tumours is considerable. • T1 values in muscle and tumours are significantly different. • Patient-specific T1 estimation is needed for comparison of inter-patient perfusion parameters. • Technical variation is higher in permeability than semiquantitative perfusion parameters.

  7. [Myocardial perfusion scintigraphy - short form of the German guideline].

    PubMed

    Lindner, O; Burchert, W; Hacker, M; Schaefer, W; Schmidt, M; Schober, O; Schwaiger, M; vom Dahl, J; Zimmermann, R; Schäfers, M

    2013-01-01

    This guideline is a short summary of the guideline for myocardial perfusion scintigraphy published by the Association of the Scientific Medical Societies in Ger-many (AWMF). The purpose of this guideline is to provide practical assistance for indication and examination procedures as well as image analysis and to present the state-of-the-art of myocardial-perfusion-scintigraphy. After a short introduction on the fundamentals of imaging, precise and detailed information is given on the indications, patient preparation, stress testing, radiopharmaceuticals, examination protocols and techniques, radiation exposure, data reconstruction as well as information on visual and quantitative image analysis and interpretation. In addition possible pitfalls, artefacts and key elements of reporting are described.

  8. Nuclear cardiology: Myocardial perfusion and function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seldin, D.W.

    1991-08-01

    Myocardial perfusion studies continue to be a major focus of research, with new investigations of the relationship of exercise-redistribution thallium imaging to diagnosis, prognosis, and case management. The redistribution phenomenon, which seemed to be fairly well understood a few years ago, is now recognized to be much more complex than originally thought, and various strategies have been proposed to clarify the meaning of persistent defects. Pharmacologic intervention with dipyridamole and adenosine has become available as an alternative to exercise, and comparisons with exercise imaging and catheterization results have been described. Thallium itself is no longer the sole single-photon perfusion radiopharmaceutical;more » two new technetium agents are now widely available. In addition to perfusion studies, advances in the study of ventricular function have been made, including reports of studies performed in conjunction with technetium perfusion studies, new insights into cardiac physiology, and the prognostic and case-management information that function studies provide. Finally, work has continued with monoclonal antibodies for the identification of areas of myocyte necrosis. 41 references.« less

  9. Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient HYPR methods in canine with stenotic coronary arteries.

    PubMed

    Ge, Lan; Kino, Aya; Lee, Daniel; Dharmakumar, Rohan; Carr, James C; Li, Debiao

    2010-01-01

    First-pass perfusion magnetic resonance imaging (MRI) is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. A combination of sliding window and conjugate-gradient HighlY constrained back-PRojection reconstruction (SW-CG-HYPR) method has been proposed in healthy volunteer studies to reduce the acquisition window for each slice while maintaining the temporal resolution of 1 frame per heartbeat in myocardial perfusion MRI. This method allows for improved spatial coverage, resolution, and SNR. In this study, we use a controlled animal model to test whether the myocardial territory supplied by a stenotic coronary artery can be detected accurately by SW-CG-HYPR perfusion method under pharmacological stress. Results from 6 mongrel dogs (15-25 kg) studies demonstrate the feasibility of SW-CG-HYPR to detect regional perfusion defects. Using this method, the acquisition time per cardiac cycle was reduced by a factor of 4, and the spatial coverage was increased from 2 to 3 slices to 6 slices as compared with the conventional techniques including both turbo-Fast Low Angle Short (FLASH) and echoplanar imaging (EPI). The SNR of the healthy myocardium at peak enhancement with SW-CG-HYPR (12.68 ± 2.46) is significantly higher (P < 0.01) than the turbo-FLASH (8.65 ± 1.93) and EPI (5.48 ± 1.24). The spatial resolution of SW-CG-HYPR images is 1.2 × 1.2 × 8.0 mm, which is better than the turbo-FLASH (1.8 × 1.8 × 8.0 mm) and EPI (2.0 × 1.8 × 8.0 mm). Sliding-window CG-HYPR is a promising technique for myocardial perfusion MRI. This technique provides higher image quality with respect to significantly improved SNR and spatial resolution of the myocardial perfusion images, which might improve myocardial perfusion imaging in a clinical setting.

  10. Effects of aortic tortuosity on left ventricular diastolic parameters derived from gated myocardial perfusion single photon emission computed tomography in patients with normal myocardial perfusion.

    PubMed

    Kurisu, Satoshi; Nitta, Kazuhiro; Sumimoto, Yoji; Ikenaga, Hiroki; Ishibashi, Ken; Fukuda, Yukihiro; Kihara, Yasuki

    2018-06-01

    Aortic tortuosity is often found on chest radiograph, especially in aged patients. We tested the hypothesis that aortic tortuosity was associated with LV diastolic parameters derived from gated SPECT in patients with normal myocardial perfusion. One-hundred and twenty-two patients with preserved LV ejection fraction and normal myocardial perfusion were enrolled. Descending aortic deviation was defined as the horizontal distance from the left line of the aortic knob to the most prominent left line of the descending aorta. This parameter was measured for the quantitative assessment of aortic tortuosity. Peak filling rate (PFR) and one-third mean filling rate (1/3 MFR) were obtained from redistribution images as LV diastolic parameters. Descending aortic deviation ranged from 0 to 22 mm with a mean distance of 4.5 ± 6.3 mm. Descending aortic deviation was significantly correlated with age (r = 0.38, p < 0.001) and estimated glomerular filtration rate (eGFR) (r = - 0.21, p = 0.02). Multivariate linear regression analysis revealed that eGFR (β = 0.23, p = 0.02) and descending aortic deviation (β = - 0.23, p = 0.01) were significantly associated with PFR, and that only descending aortic deviation (β = - 0.21, p = 0.03) was significantly associated with 1/3 MFR. Our data suggest that aortic tortuosity is associated with LV diastolic parameters derived from gated SPECT in patients with normal myocardial perfusion.

  11. Association between plasma ceramides and inducible myocardial ischemia in patients with established or suspected coronary artery disease undergoing myocardial perfusion scintigraphy.

    PubMed

    Mantovani, Alessandro; Bonapace, Stefano; Lunardi, Gianluigi; Salgarello, Matteo; Dugo, Clementina; Canali, Guido; Byrne, Christopher D; Gori, Stefania; Barbieri, Enrico; Targher, Giovanni

    2018-05-16

    Recent studies have suggested that specific plasma ceramides are independently associated with major adverse cardiovascular events in patients with coronary artery disease (CAD), but it is currently unknown whether plasma ceramide levels are associated with stress-induced reversible myocardial ischemia. We measured six previously identified high-risk plasma ceramide molecules [Cer(d18:1/16:0), Cer(d18:1/18:0), Cer(d18:1/20:0), Cer(d18:1/22:0), Cer(d18:1/24:0), and Cer(d18:1/24:1)] in 167 consecutive patients with established or suspected CAD who underwent either exercise or dypiridamole myocardial perfusion scintigraphy (MPS) for various clinical indications. Plasma ceramide levels were measured by a targeted liquid chromatography-tandem mass spectrometry assay both at baseline and after MPS. Seventy-eight patients had inducible myocardial ischemia on stress MPS. Women had significantly higher circulating levels of basal and post-stress Cer(d18:1/16:0) and Cer(d18:1/18:0) compared to men, whereas all other plasma ceramides did not differ between the sexes. Of the six measured plasma ceramides, basal Cer(d18:1/24:1) showed the strongest association with the presence of stress-induced myocardial perfusion defects in univariate analysis (unadjusted-odds ratio 1.48 per 1-SD increment, 95% confidence interval 1.08-2.04). Notably, after adjustment for age, sex, smoking, dyslipidemia, hypertension, diabetes, prior history of CAD, left ventricular ejection fraction, and type of stress testing (exercise vs. dypiridamole), all measured ceramides, except for plasma Cer(d18:1/24:0), were independently associated with the presence of inducible myocardial ischemia. Distinct plasma ceramides are positive and independent predictors of stress-induced myocardial perfusion defects in patients with established or suspected CAD referred for clinically indicated MPS. Further research is needed to examine whether distinct plasma ceramides could be a useful therapeutic target for

  12. [The development of a computer model in the quantitative assessment of thallium-201 myocardial scintigraphy].

    PubMed

    Raineri, M; Traina, M; Rotolo, A; Candela, B; Lombardo, R M; Raineri, A A

    1993-05-01

    Thallium-201 scintigraphy is a widely used noninvasive procedure for the detection and prognostic assessment of patients with suspected or proven coronary artery disease. Thallium uptake can be evaluated by a visual analysis or by a quantitative interpretation. Quantitative scintigraphy enhances disease detection in individual coronary arteries, provides a more precise estimate of the amount of ischemic myocardium, distinguishing scar from hypoperfused tissue. Due to the great deal of data, analysis, interpretation and comparison of thallium uptake can be very complex. We designed a computer-based system for the interpretation of quantitative thallium-201 scintigraphy data uptake. We used a database (DataEase 4.2-DataEase Italia). Our software has the following functions: data storage; calculation; conversion of numerical data into different definitions classifying myocardial perfusion; uptake data comparison; automatic conclusion; comparison of different scintigrams for the same patient. Our software is made up by 4 sections: numeric analysis, descriptive analysis, automatic conclusion, clinical remarks. We introduced in the computer system appropriate information, "logical paths", that use the "IF ... THEN" rules. The software executes these rules in order to analyze the myocardial regions in the 3 phases of scintigraphic analysis (stress, redistribution, re-injection), in the 3 projections (LAO 45 degrees, LAT,ANT), considering our uptake cutoff, obtaining, finally, the automatic conclusions. For these reasons, our computer-based system could be considered a real "expert system".

  13. A tourniquet assisted cardiopulmonary resuscitation augments myocardial perfusion in a porcine model of cardiac arrest.

    PubMed

    Yang, Zhengfei; Tang, David; Wu, Xiaobo; Hu, Xianwen; Xu, Jiefeng; Qian, Jie; Yang, Min; Tang, Wanchun

    2015-01-01

    During cardiopulmonary resuscitation (CPR), myocardial blood flow generated by chest compression rarely exceeds 35% of its normal level. Cardiac output generated by chest compression decreases gradually with the prolongation of cardiac arrest and resuscitation. Early studies have demonstrated that myocardial blood flow during CPR is largely dependent on peripheral vascular resistance. In this study, we investigated the effects of chest compression in combination with physical control of peripheral vascular resistance assisted by tourniquets on myocardial blood flow during CPR. Ventricular fibrillation was induced and untreated for 7 min in ten male domestic pigs weighing between 33 and 37 kg. The animals were then randomized to receive CPR alone or a tourniquet assisted CPR (T-CPR). In the CPR alone group, chest compression was performed by a miniaturized mechanical chest compressor. In the T-CPR group, coincident with the start of resuscitation, the thin elastic tourniquets were wrapped around the four limbs from the distal end to the proximal part. After 2 min of CPR, epinephrine (20 μg/kg) was administered via the femoral vein. After 5 min of CPR, defibrillation was attempted by a single 150 J shock. If resuscitation was not successful, CPR was resumed for 2 min before the next defibrillation. The protocol was continued until successful resuscitation or for a total of 15 min. Five minutes after resuscitation, the elastic tourniquets were removed. The resuscitated animals were observed for 2h. T-CPR generated significantly greater coronary perfusion pressure, end-tidal carbon dioxide and carotid blood flow. There was no difference in both intrathoracic positive and negative pressures between the two groups. All animals were successfully resuscitated with a single shock in both groups. There were no significant changes in hemodynamics observed in the animals treated in the T-CPR group before-and-after the release of tourniquets at post-resuscitation 5 min. T

  14. Radiation-induced myocardial perfusion abnormalities in breast cancer patients following external beam radiation therapy.

    PubMed

    Eftekhari, Mohammad; Anbiaei, Robabeh; Zamani, Hanie; Fallahi, Babak; Beiki, Davood; Ameri, Ahmad; Emami-Ardekani, Alireza; Fard-Esfahani, Armaghan; Gholamrezanezhad, Ali; Seid Ratki, Kazem Razavi; Roknabadi, Alireza Momen

    2015-01-01

    Radiation therapy for breast cancer can induce myocardial capillary injury and increase cardiovascular morbidity and mortality. A prospective cohort was conducted to study the prevalence of myocardial perfusion abnormalities following radiation therapy of left-sided breast cancer patients as compared to those with right-sided cancer. To minimize potential confounding factors, only those patients with low 10-year risk of coronary artery disease (based on Framingham risk scoring) were included. All patients were initially treated by modified radical mastectomy and then were managed by postoperative 3D Conformal Radiation Therapy (CRT) to the surgical bed with an additional 1-cm margin, delivered by 46-50 Gy (in 2 Gy daily fractions) over a 5-week course. The same dose-adjusted chemotherapy regimen (including anthracyclines, cyclophosphamide and taxol) was given to all patients. Six months after radiation therapy, all patients underwent cardiac SPECT for the evaluation of myocardial perfusion. A total of 71 patients with a mean age of 45.3±7.2 years [35 patients with leftsided breast cancer (exposed) and 36 patients with right-sided cancer (controls)] were enrolled. Dose-volume histogram (DVH) [showing the percentage of the heart exposed to >50% of radiation] was significantly higher in patients with left-sided breast cancer. Visual interpretation detected perfusion abnormalities in 42.9% of cases and 16.7% of controls (P=0.02, Odds ratio=1.46). In semiquantitative segmental analysis, only apical (28.6% versus 8.3%, P=0.03) and anterolateral (17.1% versus 2.8%, P=0.049) walls showed significantly reduced myocardial perfusion in the exposed group. Summed Stress Score (SSS) of>3 was observed in twelve cases (34.3%), while in five of the controls (13.9%),(Odds ratio=1.3). There was no significant difference between the groups regarding left ventricular ejection fraction. The risk of radiation induced myocardial perfusion abnormality in patients treated with CRT on the

  15. Biokinetics of radiolabeled Iodophenylpentadecanoic acid (I-123-IPPA) and thallium-201 in a rabbit model of chronic myocardial infarction measured using a series of thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Medich, David Christopher

    1997-09-01

    The biokinetics of Iodophenylpentadecanoic acid (123I-IPPA) during a chronic period of myocardial infarction were determined and compared to 201Tl. IPPA was assessed as a perfusion and metabolic tracer in the scintigraphic diagnosis of coronary artery disease. The myocardial clearance kinetics were measured by placing a series of thermoluminescent dosimeters (TLDs) on normal and infarcted tissue to measure the local myocardial activity content over time. The arterial blood pool activity was fit to a bi-exponential function for 201Tl and a tri-exponential function for 123I-IPPA to estimate the left ventricle contribution to TLD response. At equilibrium, the blood pool contribution was estimated experimentally to be less than 5% of the total TLD response. The method was unable to resolve the initial uptake of the imaging agent due in part to the 2 minute TLD response integration time and in part to the 30 second lag time for the first TLD placement. A noticeable disparity was observed between the tracer concentrations of IPPA in normal and ischemic tissue of approximately 2:1. The fitting parameters (representing the biokinetic eigenvalue rate constants) were related to the fundamental rate constants of a recycling biokinetic model. The myocardial IPPA content within normal tissue was elevated after approximately 130 minutes post injection. This phenomenon was observed in all but one (950215) of the IPPA TLD kinetics curves.

  16. Myocardial Perfusion SPECT 2015 in Germany

    PubMed Central

    Burchert, Wolfgang; Schäfer, Wolfgang; Hacker, Marcus

    2016-01-01

    Summary Aim The working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine presents the results of the 7th survey of myocardial perfusion SPECT (MPS) of the reporting year 2015. Method 268 questionnaires (173 practices [PR], 67 hospitals [HO], 28 university hospitals [UH]) were evaluated. Results of the last survey from 2012 are set in squared brackets. Results MPS of 121 939 [105 941] patients were reported. 98 % [95 %] of all MPS were performed with Tc-99m radiopharmaceuticals and 2 % [5 %] with Tl-201. 78 % [79 %] of all patients were studied in PR, 14 % [15 %] in HO, and 8 % [6 %] in UH. A pharmacological stress test was performed in 43 % [39 %] (22 % [24 %] adenosine, 20 % [9 %] regadenoson, 1% [6 %] dipyridamole or dobutamine). Attenuation correction was applied in 25 % [2009: 10 %] of MPS. Gated SPECT was performed in 78 % [70 %] of all rest MPS, in 80 % [73 %] of all stress and in 76 % [67 %] of all stress and rest MPS. 53 % [33 %] of all nuclear medicine departments performed MPS scoring by default, whereas 24 % [41 %] did not apply any quantification. 31 % [26 %] of all departments noticed an increase in their counted MPS and 29 % [29 %] no changes. Data from 89 departments which participated in all surveys showed an increase in MPS count of 11.1 % (PR: 12.2 %, HO: 4.8 %, UH: 18.4 %). 70 % [60 %] of the MPS were requested by ambulatory care cardiologists. Conclusion The 2015 MPS survey reveals a high-grade adherence of routine MPS practice to current guidelines. The positive trend in MPS performance and number of MPS already observed in 2012 continues. Educational training remains necessary in the field of SPECT scoring. PMID:27909712

  17. Toward a practical template-based approach to semiquantitative SPECT myocardial perfusion imaging.

    PubMed

    Hughes, Tyler; Celler, Anna

    2012-03-01

    Our template-based quantitative perfusion single photon emission computed tomography (SPECT) method (T-QPS) performs semiquantitative analysis for myocardial perfusion imaging (MPI) without the use of normal databases. However, in its current form, T-QPS requires extensive calculations, which limits its clinical application. In the interest of clinical feasibility, the authors examine the trade-off between accuracy and processing time as the method is simplified. The T-QPS method uses the reconstructed SPECT image of the patient to create a 3D digital template of his∕her healthy heart. This template is then projected, reconstructed, and sampled into the bulls-eye map domain. A ratio of the patient and template images produces a final corrected image in which a threshold is applied to identify perfusion defects. In principle, the template should be constructed with the heart and all extracardiac activity, and the projection step should include primary and scatter components; however, this leads to lengthy calculations. In an attempt to shorten the processing time, the authors analyzed the performance of four template (T) generation methods: T(P-HRT), T(PS-HRT), T(P-HRTBKG), and T(PS-HRTBKG), where P and S represent primary and scattered photons included in the projection step, respectively; and HRT and HRTBKG represent template constructed with the heart only and the heart with background activity, respectively. Forty-eight thorax phantoms and 21 randomly selected patient studies were analyzed using each approach. All studies used GE's Infinia Hawkeye SPECT∕CT system and followed a standard cardiac acquisition protocol. Approximate processing times for the T(P-HRT), T(PS-HRT), T(P-HRTBKG), and T(PS-HRTBKG) methods were less than a minute, 2-3 h, less than a minute and 3-4 h, respectively. In both the simulation and patient studies, a significant reduction in the quality of perfusion defect definition was exhibited by the T(P-HRT) method relative to the other

  18. Advances in PET myocardial perfusion imaging: F-18 labeled tracers.

    PubMed

    Rischpler, Christoph; Park, Min-Jae; Fung, George S K; Javadi, Mehrbod; Tsui, Benjamin M W; Higuchi, Takahiro

    2012-01-01

    Coronary artery disease and its related cardiac disorders represent the most common cause of death in the USA and Western world. Despite advancements in treatment and accompanying improvements in outcome with current diagnostic and therapeutic modalities, it is the correct assignment of these diagnostic techniques and treatment options which are crucial. From a diagnostic standpoint, SPECT myocardial perfusion imaging (MPI) using traditional radiotracers like thallium-201 chloride, Tc-99m sestamibi or Tc-99m tetrofosmin is the most utilized imaging technique. However, PET MPI using N-13 ammonia, rubidium-82 chloride or O-15 water is increasing in availability and usage as a result of the growing number of medical centers with new-generation PET/CT systems taking advantage of the superior imaging properties of PET over SPECT. The routine clinical use of PET MPI is still limited, in part because of the short half-life of conventional PET MPI tracers. The disadvantages of these conventional PET tracers include expensive onsite production and inconvenient on-scanner tracer administration making them unsuitable for physical exercise stress imaging. Recently, two F-18 labeled radiotracers with longer radioactive half-lives than conventional PET imaging agents have been introduced. These are flurpiridaz F 18 (formerly known as F-18 BMS747158-02) and F-18 fluorobenzyltriphenylphosphonium. These longer half-life F-18 labeled perfusion tracers can overcome the production and protocol limitations of currently used radiotracers for PET MPI.

  19. Confluence of depression and acute psychological stress among patients with stable coronary heart disease: effects on myocardial perfusion.

    PubMed

    Burg, Matthew M; Meadows, Judith; Shimbo, Daichi; Davidson, Karina W; Schwartz, Joseph E; Soufer, Robert

    2014-10-30

    Depression is prevalent in coronary heart disease (CHD) patients and increases risk for acute coronary syndrome (ACS) recurrence and mortality despite optimal medical care. The pathways underlying this risk remain elusive. Psychological stress (PS) can provoke impairment in myocardial perfusion and trigger ACS. A confluence of acute PS with depression might reveal coronary vascular mechanisms of risk. We tested whether depression increased risk for impaired myocardial perfusion during acute PS among patients with stable CHD. Patients (N=146) completed the Beck Depression Inventory-I (BDI-I), a measure of depression linked to recurrent ACS and post-ACS mortality, and underwent single-photon emission computed tomography myocardial perfusion imaging at rest and during acute PS. The likelihood of new/worsening impairment in myocardial perfusion from baseline to PS as a function of depression severity was tested. On the BDI-I, 41 patients scored in the normal range, 48 in the high normal range, and 57 in the depressed range previously linked to CHD prognosis. A BDI-I score in the depressed range was associated with a significantly greater likelihood of new/worsening impairment in myocardial perfusion from baseline to PS (odds ratio =2.89, 95% CI: 1.26 to 6.63, P=0.012). This remained significant in models controlling ACS recurrence/mortality risk factors and medications. There was no effect for selective serotonin reuptake inhibitor medications. Depressed patients with CHD are particularly susceptible to impairment in myocardial perfusion during PS. The confluence of PS with depression may contribute to a better understanding of the depression-associated risk for ACS recurrence and mortality. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  20. Relationship between regional myocardial blood flow and thallium-201 distribution in the presence of coronary artery stenosis and dipyridamole-induced vasodilation.

    PubMed Central

    Mays, A E; Cobb, F R

    1984-01-01

    This study assesses the relationship between the distribution of thallium-201 and myocardial blood flow during coronary vasodilation induced by intravenous dipyridamole in canine models of partial and complete coronary artery stenosis. 10 dogs were chronically instrumented with catheters in the left atrium and aorta and with a balloon occluder and electromagnetic flow probe on the proximal left circumflex coronary artery. Regional myocardial blood flow was measured during control conditions with radioisotope-labeled microspheres, and the phasic reactive hyperemic response to a 20-s transient occlusion was then recorded. Dipyridamole was then infused intravenously until phasic coronary blood flow increased to match peak hyperemic values. The left circumflex coronary artery was either partially occluded to reduce phasic blood flow to control values (group 1) or it was completely occluded (group 2), and thallium-201 and a second microsphere label were injected. 5 min later, the animals were sacrificed, the left ventricle was sectioned into 1-2-g samples, and thallium-201 activity and regional myocardial blood flow were measured. Curvilinear regression analyses between thallium-201 localization and myocardial blood flow during dipyridamole infusion demonstrated a slightly better fit to a second- as compared with a first-order model, indicating a slight roll-off of thallium activity as myocardial blood flow increases. During the dipyridamole infusion, the increases in phasic blood flow, the distributions of regional myocardial blood flow, and the relationships between thallium-201 localization and regional blood flow were comparable to values previously observed in exercising dogs with similar occlusions. These data provide basic validation that supports the use of intravenous dipyridamole and thallium-201 as an alternative to exercise stress and thallium-201 for evaluating the effects of coronary occlusive lesions on the distribution of regional myocardial blood flow

  1. Real-time myocardial perfusion imaging for pharmacologic stress testing: added value to single photon emission computed tomography.

    PubMed

    Korosoglou, Grigorios; Dubart, Alain-Eric; DaSilva, K Gaspar C; Labadze, Nino; Hardt, Stefan; Hansen, Alexander; Bekeredjian, Raffi; Zugck, Christian; Zehelein, Joerg; Katus, Hugo A; Kuecherer, Helmut

    2006-01-01

    Little is known about the incremental value of real-time myocardial contrast echocardiography (MCE) as an adjunct to pharmacologic stress testing. This study was performed to evaluate the diagnostic value of MCE to detect abnormal myocardial perfusion by technetium Tc 99m sestamibi-single photon emission computed tomography (SPECT) and anatomically significant coronary artery disease (CAD) by angiography. Myocardial contrast echocardiography was performed at rest and during vasodilator stress in consecutive patients (N = 120) undergoing SPECT imaging for known or suspected CAD. Myocardial opacification, wall motion, and tracer uptake were visually analyzed in 12 myocardial segments by 2 pairs of blinded observers. Concordance between the 2 methods was assessed using the kappa statistic. Of 1356 segments, 1025 (76%) were interpretable by MCE, wall motion, and SPECT. Sensitivity of wall motion was 75%, specificity 83%, and accuracy 81% for detecting abnormal myocardial perfusion by SPECT (kappa = 0.53). Myocardial contrast echocardiography and wall motion together yielded significantly higher sensitivity (85% vs 74%, P < .05), specificity of 83%, and accuracy of 85% (kappa = 0.64) for the detection of abnormal myocardial perfusion. In 89 patients who underwent coronary angiography, MCE and wall motion together yielded higher sensitivity (83% vs 64%, P < .05) and accuracy (77% vs 68%, P < .05) but similar specificity (72%) compared with SPECT for the detection of high-grade, stenotic (> or = 75%) coronary lesions. Assessment of myocardial perfusion adds value to conventional stress echocardiography by increasing its sensitivity for the detection of functionally abnormal myocardial perfusion. Myocardial contrast echocardiography and wall motion together provide higher sensitivity and accuracy for detection of CAD compared with SPECT.

  2. Prevalence of silent myocardial ischaemia during exercise stress testing. Its relation to effort tolerance and myocardial perfusion abnormalities.

    PubMed

    Fragasso, G; Sciammarella, M G; Rossetti, E E; Xuereb, R G; Xuereb, M; Bonetti, F; Carandente, O M; Margonato, A; Chierchia, S L

    1992-07-01

    The number of underperfused myocardial segments, the extent of coronary artery disease and the severity of impairment of coronary flow reserve were compared in 147 consecutive patients exhibiting painful or painless ischaemic ST segment depression on exercise testing. Of 147 patients, only 61 (41%) experienced angina (group 1) whilst 86 (59%) did not (group 2). In the two groups coronary disease was comparable for both extent and distribution, and neither the location of transient perfusion defects nor their relation to areas of old myocardial necrosis appeared to influence the presence or absence of chest pain. However, exercise duration, exercise time and rate-pressure product at the beginning of ischaemia were lower in group 1. Furthermore, a greater proportion of asymptomatic patients had only one ischaemic segment on 99mTc-MIBI perfusion scintigraphy. We conclude that: (1) in patients with effort angina and coronary disease, the incidence of electrocardiographic silent ischaemic events induced by exercise is similar to that observed in studies based on continuous ECG monitoring. (2) Exertional angina is more frequently associated with greater ischaemic areas and with more severe degrees of impairment of residual coronary flow reserve. (3) The presence of an old myocardial infarction does not appear to influence the incidence of ischaemic cardiac pain.

  3. Assessment of myocardial fibrosis with T1 mapping MRI.

    PubMed

    Everett, R J; Stirrat, C G; Semple, S I R; Newby, D E; Dweck, M R; Mirsadraee, S

    2016-08-01

    Myocardial fibrosis can arise from a range of pathological processes and its presence correlates with adverse clinical outcomes. Cardiac magnetic resonance (CMR) can provide a non-invasive assessment of cardiac structure, function, and tissue characteristics, which includes late gadolinium enhancement (LGE) techniques to identify focal irreversible replacement fibrosis with a high degree of accuracy and reproducibility. Importantly the presence of LGE is consistently associated with adverse outcomes in a range of common cardiac conditions; however, LGE techniques are qualitative and unable to detect diffuse myocardial fibrosis, which is an earlier form of fibrosis preceding replacement fibrosis that may be reversible. Novel T1 mapping techniques allow quantitative CMR assessment of diffuse myocardial fibrosis with the two most common measures being native T1 and extracellular volume (ECV) fraction. Native T1 differentiates normal from infarcted myocardium, is abnormal in hypertrophic cardiomyopathy, and may be particularly useful in the diagnosis of Anderson-Fabry disease and amyloidosis. ECV is a surrogate measure of the extracellular space and is equivalent to the myocardial volume of distribution of the gadolinium-based contrast medium. It is reproducible and correlates well with fibrosis on histology. ECV is abnormal in patients with cardiac failure and aortic stenosis, and is associated with functional impairment in these groups. T1 mapping techniques promise to allow earlier detection of disease, monitor disease progression, and inform prognosis; however, limitations remain. In particular, reference ranges are lacking for T1 mapping values as these are influenced by specific CMR techniques and magnetic field strength. In addition, there is significant overlap between T1 mapping values in healthy controls and most disease states, particularly using native T1, limiting the clinical application of these techniques at present. Copyright © 2016 The Royal College

  4. Functional CT assessment of extravascular contrast distribution volume and myocardial perfusion in acute myocardial infarction.

    PubMed

    So, Aaron; Wisenberg, Gerald; Teefy, Patrick; Yadegari, Andrew; Bagur, Rodrigo; Hadway, Jennifer; Morrison, Laura; MacDonald, Anna; Gaskin, Dave; Butler, John; Biernaski, Heather; Skanes, Stephanie; Park, Stella DohYeoun; Islam, Ali; Hsieh, Jiang; Lee, Ting-Yim

    2018-04-26

    In a pig model of acute myocardial infarction (AMI), we validated a functional computed tomography (CT) technique for concomitant assessment of myocardial edema and ischemia through extravscualar contrast distribution volume (ECDV) and myocardial perfusion (MP) measurements from a single dynamic imaging session using a single contrast bolus injection. In seven pigs, balloon catheter was used to occlude the distal left anterior descending artery for one hour followed by reperfusion. CT and cardiac magnetic resonance (CMR) imaging studies were acquired on 3 days and 12 ± 3 day post ischemic insult. In each CT study, 0.7 ml/kg of iodinated contrast was intravenously injected at 3-4 ml/s before dynamic contrast-enhanced (DCE) cardiac images were acquired with breath-hold using a 64-row CT scanner. DCE cardiac images were analyzed with a model-based deconvolution to generate ECDV and MP maps. ECDV as an imaging marker of edema was validated against CMR T2 weighted imaging in normal and infarcted myocardium delineated from ex-vivo histological staining. ECDV in infarcted myocardium was significantly higher (p < 0.05) than that in normal myocardium on both days post AMI and was in agreement with the findings of CMR T2 weighted imaging. MP was significantly lower (p < 0.05) in the infarcted region compared to normal on both days post AMI. This imaging technique can rapidly and simultaneously assess myocardial edema and ischemia through ECDV and MP measurements, and may be useful for delineation of salvageable tissue within at-risk myocardium to guide reperfusion therapy. Copyright © 2017. Published by Elsevier B.V.

  5. Optimization of Spiral-Based Pulse Sequences for First Pass Myocardial Perfusion Imaging

    PubMed Central

    Salerno, Michael; Sica, Christopher T.; Kramer, Christopher M.; Meyer, Craig H.

    2010-01-01

    While spiral trajectories have multiple attractive features such as their isotropic resolution, acquisition efficiency, and robustness to motion, there has been limited application of these techniques to first pass perfusion imaging because of potential off-resonance and inconsistent data artifacts. Spiral trajectories may also be less sensitive to dark-rim artifacts (DRA) that are caused, at least in part, by cardiac motion. By careful consideration of the spiral trajectory readout duration, flip angle strategy, and image reconstruction strategy, spiral artifacts can be abated to create high quality first pass myocardial perfusion images with high SNR. The goal of this paper was to design interleaved spiral pulse sequences for first-pass myocardial perfusion imaging, and to evaluate them clinically for image quality and the presence of dark-rim, blurring, and dropout artifacts. PMID:21590802

  6. Diagnostic value of thallium-201 myocardial perfusion IQ-SPECT without and with computed tomography-based attenuation correction to predict clinically significant and insignificant fractional flow reserve

    PubMed Central

    Tanaka, Haruki; Takahashi, Teruyuki; Ohashi, Norihiko; Tanaka, Koichi; Okada, Takenori; Kihara, Yasuki

    2017-01-01

    Abstract The aim of this study was to clarify the predictive value of fractional flow reserve (FFR) determined by myocardial perfusion imaging (MPI) using thallium (Tl)-201 IQ-SPECT without and with computed tomography-based attenuation correction (CT-AC) for patients with stable coronary artery disease (CAD). We assessed 212 angiographically identified diseased vessels using adenosine-stress Tl-201 MPI-IQ-SPECT/CT in 84 consecutive, prospectively identified patients with stable CAD. We compared the FFR in 136 of the 212 diseased vessels using visual semiquantitative interpretations of corresponding territories on MPI-IQ-SPECT images without and with CT-AC. FFR inversely correlated most accurately with regional summed difference scores (rSDS) in images without and with CT-AC (r = −0.584 and r = −0.568, respectively, both P < .001). Receiver-operating characteristics analyses using rSDS revealed an optimal FFR cut-off of <0.80 without and with CT-AC. Although the diagnostic accuracy of FFR <0.80 did not significantly differ, FFR ≥0.82 was significantly more accurate with, than without CT-AC. Regions with rSDS ≥2 without or with CT-AC predicted FFR <0.80, and those with rSDS ≤1 without and with CT-AC predicted FFR ≥0.81, with 73% and 83% sensitivity, 84% and 67% specificity, and 79% and 75% accuracy, respectively. Although limited by the sample size and the single-center design, these findings showed that the IQ-SPECT system can predict FFR at an optimal cut-off of <0.80, and we propose a novel application of CT-AC to MPI-IQ-SPECT for predicting clinically significant and insignificant FFR even in nonobese patients. PMID:29390486

  7. Comparison between fragmented QRS and Q waves in myocardial scar detection using myocardial perfusion single photon emission computed tomography.

    PubMed

    Dabbagh Kakhki, Vahid Reza; Ayati, Narjess; Zakavi, Seyed Rasoul; Sadeghi, Ramin; Tayyebi, Mohammad; Shariati, Farzaneh

    2015-01-01

    Accurate diagnosis of myocardial infarction (MI) is of paramount importance in patient management, which necessitates the development of efficient and accurate diagnostic methods. Q wave is not present in all patients with MI, and its prevalence is declining. Recently, fragmented QRS (fQRS) complex has been introduced as a marker of prior MI. To investigate diagnostic value of fQRS compared to Q wave. We included 500 consecutive patients with known or suspected coronary artery disease who underwent two days of gated myocardial perfusion imaging using dipyridamole pharmacologic stress. Electrocardiogram (ECG) was evaluated to detect fQRS as well as Q-wave. Finally, subjects were compared in terms of ventricular perfusion and function indices. A total of 207 men and 269 women with mean age of 57.06 ± 12 years were studied. ECG analysis showed that 14.3% of the patients had both fQRS and Q waves, 30.7% had fQRS, and 3.8% had Q waves. Fixed myocardial perfusion defect was noted in 22.3% of patients according to MPIs. Sensitivity, specificity, and positive and negative predictive values for myocardial scar detection were 78%, 65%, 39%, and 91%, respectively, for fQRS and 61%, 94%, 76%, and 89%, respectively, for Q wave. Although fQRS had lower specificity compared to Q wave in the detection of myocardial scar, due to higher sensitivity and negative predictive value can be an invaluable diagnostic index. There is also an incremental value for fQRS in association with Q-wave in myocardial scar assessment.

  8. Exercise thallium-201 perfusion scintigraphy in the assessment of coronary artery disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahmarian, J.J.; Verani, M.S.

    1991-05-21

    Exercise thallium-201 perfusion scintigraphy has been used extensively over the last decade for the detection and localization of coronary artery disease. Single-photon emission computed tomography (SPECT) is a refinement of presently available techniques, offering improved identification over planar imaging of individual vessel stenosis and quantification of the extent of abnormally perfused myocardium. In this review, the planar and SPECT techniques are discussed in light of the most recently published large patient series, and with regard to the many factors that affect the sensitivity and specificity of perfusion imaging in identifying coronary artery disease. The clinical implications of exercise perfusion scintigraphymore » and its future applications in cardiology practice are discussed.67 references.« less

  9. Simultaneous assessment of myocardial perfusion and function during mental stress in patients with chronic coronary artery disease.

    PubMed

    Arrighi, James A; Burg, Matthew; Cohen, Ira S; Soufer, Robert

    2003-01-01

    Mental stress (MS) is an important provocateur of myocardial ischemia in many patients with chronic coronary artery disease. The majority of laboratory assessments of ischemia in response to MS have included measurements of either myocardial perfusion or function alone. We performed this study to determine the relationship between alterations in perfusion and ventricular function during MS. Methods and results Twenty-eight patients with reversible perfusion defects on exercise or pharmacologic stress myocardial perfusion imaging (MPI) underwent simultaneous technetium 99m sestamibi single photon emission computed tomography (SPECT) MPI and transthoracic echocardiography at rest and during MS according to a mental arithmetic protocol. In all cases the MS study was performed within 4 weeks of the initial exercise or pharmacologic MPI that demonstrated ischemia. SPECT studies were analyzed visually with the use of a 13-segment model and quantitatively by semiautomated circumferential profile analysis. Echocardiograms were graded on a segmental model for regional wall motion on a 4-point scale. Of 28 patients, 18 (64%) had perfusion defects and/or left ventricular dysfunction develop during MS: 9 (32%) had myocardial perfusion defects develop, 6 (21%) had regional or global left ventricular dysfunction develop, and 3 (11%) had both perfusion defects and left ventricular dysfunction develop. The overall concordance between perfusion and function criteria for ischemia during MS was only 46%. Among 9 patients with MS-induced left ventricular dysfunction, 5 had new regional wall motion abnormalities and 4 had a global decrement in function. In patients with MS-induced ischemia by SPECT, the number of reversible perfusion defects was similar during both MS and exercise/pharmacologic stress (2.8 +/- 2.0 vs 3.5 +/- 1.8, P =.41). Hemodynamic changes during MS were similar whether patients were divided on the basis of perfusion defects or left ventricular dysfunction during MS

  10. Resting electrocardiogram and stress myocardial perfusion imaging in the determination of left ventricular systolic function: an assessment enhancing the performance of gated SPET.

    PubMed

    Moralidis, Efstratios; Spyridonidis, Tryfon; Arsos, Georgios; Skeberis, Vassilios; Anagnostopoulos, Constantinos; Gavrielidis, Stavros

    2010-01-01

    This study aimed to determine systolic dysfunction and estimate resting left ventricular ejection fraction (LVEF) from information collected during routine evaluation of patients with suspected or known coronary heart disease. This approach was then compared to gated single photon emission tomography (SPET). Patients having undergone stress (201)Tl myocardial perfusion imaging followed by equilibrium radionuclide angiography (ERNA) were separated into derivation (n=954) and validation (n=309) groups. Logistic regression analysis was used to develop scoring systems, containing clinical, electrocardiographic (ECG) and scintigraphic data, for the discrimination of an ERNA-LVEF<0.50. Linear regression analysis provided equations predicting ERNA-LVEF from those scores. In 373 patients LVEF was also assessed with (201)Tl gated SPET. Our results showed that an ECG-Scintigraphic scoring system was the best simple predictor of an ERNA-LVEF<0.50 in comparison to other models including ECG, clinical and scintigraphic variables in both the derivation and validation subpopulations. A simple linear equation was derived also for the assessment of resting LVEF from the ECG-Scintigraphic model. Equilibrium radionuclide angiography-LVEF had a good correlation with the ECG-Scintigraphic model LVEF (r=0.716, P=0.000), (201)Tl gated SPET LVEF (r=0.711, P=0.000) and the average LVEF from those assessments (r=0.796, P=0.000). The Bland-Altman statistic (mean+/-2SD) provided values of 0.001+/-0.176, 0.071+/-0.196 and 0.040+/-0.152, respectively. The average LVEF was a better discriminator of systolic dysfunction than gated SPET-LVEF in receiver operating characteristic (ROC) analysis and identified more patients (89%) with a myocardial perfusion imaging variables. This model provides reliable LVEF

  11. [Myocardial perfusion imaging by digital subtraction angiography].

    PubMed

    Kadowaki, H; Ishikawa, K; Ogai, T; Katori, R

    1986-03-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. 123I-BMIPP fatty acid analogue imaging is a novel diagnostic and prognostic approach following acute myocardial infarction.

    PubMed

    Biswas, S K; Sarai, M; Hishida, H; Ozaki, Y

    2009-10-01

    Fatty acid oxidation is the most efficient mode of myocardial energy production which requires a large amount of oxygen. Thus, alteration of fatty acid oxidation is considered to be a sensitive marker of ischaemia and myocardial damage. (123)I-BMIPP ([123]I-beta-methyl-p-iodophenylpentadecanoic acid) is a newly-investigated single-photon branching free fatty acid radiopharmaceutical with slow metabolism; thus, it is well-suited for single-photon emission computed tomography (SPECT). Assessment of fatty acid metabolism by radionuclide techniques has a potential role for the early detection of myocardial ischaemia and the assessment of the severity of ischaemic heart disease. Although stable patients with a healed myocardial infarction may have a relatively good prognosis, risk stratification in the predischarge period should be valuable for deciding upon appropriate management. In this respect, the presence of discordant BMIPP uptake relative to (201)Tl perfusion appears to be the best predictor of future cardiac events among all other cardiovascular imaging modalities. Since discordant BMIPP uptake correlates well with redistribution on stress (201)Tl imaging and perfusion-metabolism mismatch on positron emission tomography, it is considered that such BMIPP and (201)Tl discordance may identify a high-risk subgroup among patients with acute myocardial infarction. A BMIPP scan may reflect prior severe ischaemia after recovery of perfusion, the so-called "ischaemic memory". Gated BMIPP SPECT has been recently introduced for simultaneous assessment of myocardial metabolism and ventricular function. Such a new technique seems to be valuable for a better understanding of the pathophysiological state of heart failure and cardiomyopathy.

  13. Regional cardiac wall motion from gated myocardial perfusion SPECT studies

    NASA Astrophysics Data System (ADS)

    Smith, M. F.; Brigger, P.; Ferrand, S. K.; Dilsizian, V.; Bacharach, S. L.

    1999-06-01

    A method for estimating regional epicardial and endocardial wall motion from gated myocardial perfusion SPECT studies has been developed. The method uses epicardial and endocardial boundaries determined from four long-axis slices at each gate of the cardiac cycle. The epicardial and endocardial wall position at each time gate is computed with respect to stationary reference ellipsoids, and wall motion is measured along lines normal to these ellipsoids. An initial quantitative evaluation of the method was made using the beating heart from the dynamic mathematical cardiac torso (MCAT) phantom, with and without a 1.5-cm FWHM Gaussian blurring filter. Epicardial wall motion was generally well-estimated within a fraction of a 3.56-mm voxel, although apical motion was overestimated with the Gaussian filter. Endocardial wall motion was underestimated by about two voxels with and without the Gaussian filter. The MCAT heart phantom was modified to model hypokinetic and dyskinetic wall motion. The wall motion analysis method enabled this abnormal motion to be differentiated from normal motion. Regional cardiac wall motion also was analyzed for /sup 201/Tl patient studies. Estimated wall motion was consistent with a nuclear medicine physician's visual assessment of motion from gated long-axis slices for male and female study examples. Additional research is required for a comprehensive evaluation of the applicability of the method to patient studies with normal and abnormal wall motion.

  14. Direct comparison of rest and adenosine stress myocardial perfusion CT with rest and stress SPECT

    PubMed Central

    Okada, David R.; Ghoshhajra, Brian B.; Blankstein, Ron; Rocha-Filho, Jose A.; Shturman, Leonid D.; Rogers, Ian S.; Bezerra, Hiram G.; Sarwar, Ammar; Gewirtz, Henry; Hoffmann, Udo; Mamuya, Wilfred S.; Brady, Thomas J.; Cury, Ricardo C.

    2010-01-01

    Introduction We have recently described a technique for assessing myocardial perfusion using adenosine-mediated stress imaging (CTP) with dual source computed tomography. SPECT myocardial perfusion imaging (SPECT-MPI) is a widely utilized and extensively validated method for assessing myocardial perfusion. The aim of this study was to determine the level of agreement between CTP and SPECT-MPI at rest and under stress on a per-segment, per-vessel, and per-patient basis. Methods Forty-seven consecutive patients underwent CTP and SPECT-MPI. Perfusion images were interpreted using the 17 segment AHA model and were scored on a 0 (normal) to 3 (abnormal) scale. Summed rest and stress scores were calculated for each vascular territory and patient by adding corresponding segmental scores. Results On a per-segment basis (n = 799), CTP and SPECT-MPI demonstrated excellent correlation: Goodman-Kruskall γ = .59 (P < .0001) for stress and .75 (P < .0001) for rest. On a per-vessel basis (n = 141), CTP and SPECT-MPI summed scores demonstrated good correlation: Pearson r = .56 (P < .0001) for stress and .66 (P < .0001) for rest. On a per-patient basis (n = 47), CTP and SPECT-MPI demonstrated good correlation: Pearson r = .60 (P < .0001) for stress and .76 (P < .0001) for rest. Conclusions CTP compares favorably with SPECT-MPI for detection, extent, and severity of myocardial perfusion defects at rest and stress. PMID:19936863

  15. Myocardial perfusion scintigraphy: the evidence

    PubMed Central

    Anagnostopoulos, C.; Cerqueira, M.; Ell, P. J.; Flint, E. J.; Harbinson, M.; Kelion, A. D.; Al-Mohammad, A.; Prvulovich, E. M.; Shaw, L. J.; Tweddel, A. C.

    2003-01-01

    This review summarises the evidence for the role of myocardial perfusion scintigraphy (MPS) in patients with known or suspected coronary artery disease. It is the product of a consensus conference organised by the British Cardiac Society, the British Nuclear Cardiology Society and the British Nuclear Medicine Society and is endorsed by the Royal College of Physicians of London and the Royal College of Radiologists. It was used to inform the UK National Institute of Clinical Excellence in their appraisal of MPS in patients with chest pain and myocardial infarction. MPS is a well-established, non-invasive imaging technique with a large body of evidence to support its effectiveness in the diagnosis and management of angina and myocardial infarction. It is more accurate than the exercise ECG in detecting myocardial ischaemia and it is the single most powerful technique for predicting future coronary events. The high diagnostic accuracy of MPS allows reliable risk stratification and guides the selection of patients for further interventions, such as revascularisation. This in turn allows more appropriate utilisation of resources, with the potential for both improved clinical outcomes and greater cost-effectiveness. Evidence from modelling and observational studies supports the enhanced cost-effectiveness associated with MPS use. In patients presenting with stable or acute chest pain, strategies of investigation involving MPS are more cost-effective than those not using the technique. MPS also has particular advantages over alternative techniques in the management of a number of patient subgroups, including women, the elderly and those with diabetes, and its use will have a favourable impact on cost-effectiveness in these groups. MPS is already an integral part of many clinical guidelines for the investigation and management of angina and myocardial infarction. However, the technique is underutilised in the UK, as judged by the inappropriately long waiting times and by

  16. Diagnostic and clinical benefit of combined coronary calcium and perfusion assessment in patients undergoing PET/CT myocardial perfusion stress imaging.

    PubMed

    Bybee, Kevin A; Lee, John; Markiewicz, Richard; Longmore, Ryan; McGhie, A Iain; O'Keefe, James H; Hsu, Bai-Ling; Kennedy, Kevin; Thompson, Randall C; Bateman, Timothy M

    2010-04-01

    A limitation of stress myocardial perfusion imaging (MPI) is the inability to detect non-obstructive coronary artery disease (CAD). One advantage of MPI with a hybrid CT device is the ability to obtain same-setting measurement of the coronary artery calcium score (CACS). Utilizing our single-center nuclear database, we identified 760 consecutive patients with: (1) no CAD history; (2) a normal clinically indicated Rb-82 PET/CT stress perfusion study; and (3) a same-setting CAC scan. 487 of 760 patients (64.1%) had subclinical CAD based on an abnormal CACS. Of those with CAC, the CACS was > or =100, > or =400, and > or =1000 in 47.0%, 22.4%, and 8.4% of patients, respectively. Less than half of the patients with CAC were receiving aspirin or statin medications prior to PET/CT imaging. Patients with CAC were more likely to be initiated or optimized on proven medical therapy for CAD immediately following PET/CT MPI compared to those without CAC. Subclinical CAD is common in patients without known CAD and normal myocardial perfusion assessed by hybrid PET/CT imaging. Identification of CAC influences subsequent physician prescribing patterns such that those with CAC are more likely to be treated with proven medical therapy for the treatment of CAD.

  17. Importance of tissue perfusion in ST segment elevation myocardial infarction patients undergoing reperfusion strategies: role of adenosine.

    PubMed

    Forman, Mervyn B; Jackson, Edwin K

    2007-11-01

    High risk ST segment elevation myocardial infarction (STEMI) patients undergoing reperfusion therapy continue to exhibit significant morbidity and mortality due in part to myocardial reperfusion injury. Importantly, preclinical studies demonstrate that progressive microcirculatory failure (the "no-reflow" phenomenon) contributes significantly to myocardial reperfusion injury. Diagnostic techniques to measure tissue perfusion have validated this concept in humans, and it is now clear that abnormal tissue perfusion occurs frequently in STEMI patients undergoing reperfusion therapy. Moreover, because tissue perfusion correlates poorly with epicardial blood flow (TIMI flow grade), clinical studies show that tissue perfusion is an independent predictor of early and late mortality in STEMI patients and is associated with infarct size, ventricular function, CHF and ventricular arrhythmias. The mechanisms responsible for abnormal tissue perfusion are multifactorial and include both mechanical obstruction and vasoconstrictor humoral factors. Adenosine, an endogenous nucleoside, maintains microcirculatory flow following reperfusion by activating four well-characterized extracellular receptors. Because activation of adenosine receptors attenuates the mechanical and functional mechanisms leading to the "no reflow" phenomenon and activates other cardioprotective pathways as well, it is not surprising that both experimental and clinical studies show striking myocardial salvage with intravenous infusions of adenosine administered in the peri-reperfusion period. For example, a post hoc analysis of the AMISTAD II trial indicates a significant reduction in 1 and 6-month mortality in STEMI patients undergoing reperfusion therapy who are treated with adenosine within 3 hours of symptoms. In conclusion, adenosine's numerous cardioprotective effects, including attenuation of the "no-reflow" phenomenon, support its use in high risk STEMI undergoing reperfusion.

  18. Prevalence of ECG changes during adenosine stress and its association with perfusion defect on myocardial perfusion scintigraphy.

    PubMed

    Taywade, Sameer K; Ramaiah, Vijayaraghavan L; Basavaraja, Harish; Venkatasubramaniam, Parameswaran R; Selvakumar, Job

    2017-04-01

    Myocardial perfusion scintigraphy (MPS) is a valuable, noninvasive imaging modality in the evaluation of patients with coronary artery disease. Adenosine stress may occasionally be associated with ECG changes. This study evaluated the strength of association between adenosine stress-related ECG changes and perfusion defects on Tc-MPS. 117 (mean age: 61.25±9.27 years; sex: men 87, women 30) patients with known/suspected coronary artery disease underwent adenosine stress MPS. ECG was monitored continuously during adenosine stress for ST-depression. On the basis of the summed difference score, reversible perfusion defects were categorized as follows: normal: less than 4, mild: 4-8, moderate: 9-13, and severe: more than 13. ST-depression was observed in 27/117 (23.1%) and reversible perfusion defects were observed in 18/27 (66.66%) patients. 2/27, 6/27, and 10/27 patients had mild, moderate, and severe ischemia, respectively. 9/27 patients had normal perfusion. ECG changes and perfusion defects showed a moderate strength of association (correlation coefficient r=0.35, P=0.006). The sensitivity, specificity, positive predictive value, and negative predictive value of ECG findings for prediction of ischemia were 35.29, 86.36, 67.67, and 63.33%, respectively. ECG changes during adenosine stress are not uncommon. It shows a moderate strength of association with reversible perfusion defects. ECG changes during adenosine merit critical evaluation of MPS findings.

  19. Functional Cardiac Magnetic Resonance Imaging (MRI) in the Assessment of Myocardial Viability and Perfusion

    PubMed Central

    2003-01-01

    Executive Summary Objective The objective of this health technology policy assessment was to determine the effectiveness safety and cost-effectiveness of using functional cardiac magnetic resonance imaging (MRI) for the assessment of myocardial viability and perfusion in patients with coronary artery disease and left ventricular dysfunction. Results Functional MRI has become increasingly investigated as a noninvasive method for assessing myocardial viability and perfusion. Most patients in the published literature have mild to moderate impaired LV function. It is possible that the severity of LV dysfunction may be an important factor that can alter the diagnostic accuracy of imaging techniques. There is some evidence of comparable or better performance of functional cardiac MRI for the assessment of myocardial viability and perfusion compared with other imaging techniques. However limitations to most of the studies included: Functional cardiac MRI studies that assess myocardial viability and perfusion have had small sample sizes. Some studies assessed myocardial viability/perfusion in patients who had already undergone revascularization, or excluded patients with a prior MI (Schwitter et al., 2001). Lack of explicit detail of patient recruitment. Patients with LVEF >35%. Interstudy variability in post MI imaging time(including acute or chronic MI), when patients with a prior MI were included. Poor interobserver agreement (kappa statistic) in the interpretation of the results. Traditionally, 0.80 is considered “good”. Cardiac MRI measurement of myocardial perfusion to as an adjunct tool to help diagnose CAD (prior to a definitive coronary angiography) has also been examined in some studies, with methodological limitations, yielding comparable results. Many studies examining myocardial viability and perfusion report on the accuracy of imaging methods with limited data on long-term patient outcome and management. Kim et al. (2000) revealed that the transmural

  20. Image registration and analysis for quantitative myocardial perfusion: application to dynamic circular cardiac CT.

    PubMed

    Isola, A A; Schmitt, H; van Stevendaal, U; Begemann, P G; Coulon, P; Boussel, L; Grass, M

    2011-09-21

    Large area detector computed tomography systems with fast rotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively, ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce x-ray dose and limit motion artefacts. Even in the case of highly accurate prospective triggering and stable heart rate, spatial misalignment of the cardiac volumes acquired and reconstructed per cardiac cycle may occur due to small motion pattern variations from cycle to cycle. These misalignments reduce the accuracy of the quantitative analysis of myocardial perfusion parameters on a per voxel basis. An image-based solution to this problem is elastic 3D image registration of dynamic volume sequences with variable contrast, as it is introduced in this contribution. After circular cone-beam CT reconstruction of cardiac volumes covering large areas of the myocardial tissue, the complete series is aligned with respect to a chosen reference volume. The results of the registration process and the perfusion analysis with and without registration are evaluated quantitatively in this paper. The spatial alignment leads to improved quantification of myocardial perfusion for three different pig data sets.

  1. Evaluation of mechanical dyssynchrony and myocardial perfusion using phase analysis of gated SPECT imaging in patients with left ventricular dysfunction

    PubMed Central

    Trimble, Mark A.; Borges-Neto, Salvador; Honeycutt, Emily F.; Shaw, Linda K.; Pagnanelli, Robert; Chen, Ji; Iskandrian, Ami E.; Garcia, Ernest V.; Velazquez, Eric J.

    2010-01-01

    Background Using phase analysis of gated single photon emission computed tomography (SPECT) imaging, we examined the relation between myocardial perfusion, degree of electrical dyssynchrony, and degree of SPECT-derived mechanical dyssynchrony in patients with left ventricular (LV) dysfunction. Methods and Results We retrospectively examined 125 patients with LV dysfunction and ejection fraction of 35% or lower. Fourier analysis converts regional myocardial counts into a continuous thickening function, allowing resolution of phase of onset of myocardial thickening. The SD of LV phase distribution (phase SD) and histogram bandwidth describe LV phase dispersion as a measure of dyssynchrony. Heart failure (HF) patients with perfusion abnormalities ities have higher degrees of dyssynchrony measured by median phase SD (45.5° vs 27.7°, P < .0001) and bandwidth (117.0° vs 73.0°, P = .0006). HF patients with prolonged QRS durations have higher degrees of dyssynchrony measured by median phase SD (54.1° vs 34.7°, P < .0001) and bandwidth (136.5° vs 99.0°, P = .0005). Mild to moderate correlations exist between QRS duration and phase analysis indices of phase SD (r = 0.50) and bandwidth (r = 0.40). Mechanical dyssynchrony (phase SD >43°) was 43.2%. Conclusions HF patients with perfusion abnormalities or prolonged QRS durations QRS durations have higher degrees of mechanical dyssynchrony. Gated SPECT myocardial perfusion imaging can quantify myocardial function, perfusion, and dyssynchrony and may help in evaluating patients for cardiac resynchronization therapy. PMID:18761269

  2. Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient highly constrained back-projection reconstruction for detection of coronary artery disease.

    PubMed

    Ma, Heng; Yang, Jun; Liu, Jing; Ge, Lan; An, Jing; Tang, Qing; Li, Han; Zhang, Yu; Chen, David; Wang, Yong; Liu, Jiabin; Liang, Zhigang; Lin, Kai; Jin, Lixin; Bi, Xiaoming; Li, Kuncheng; Li, Debiao

    2012-04-15

    Myocardial perfusion magnetic resonance imaging (MRI) with sliding-window conjugate-gradient highly constrained back-projection reconstruction (SW-CG-HYPR) allows whole left ventricular coverage, improved temporal and spatial resolution and signal/noise ratio, and reduced cardiac motion-related image artifacts. The accuracy of this technique for detecting coronary artery disease (CAD) has not been determined in a large number of patients. We prospectively evaluated the diagnostic performance of myocardial perfusion MRI with SW-CG-HYPR in patients with suspected CAD. A total of 50 consecutive patients who were scheduled for coronary angiography with suspected CAD underwent myocardial perfusion MRI with SW-CG-HYPR at 3.0 T. The perfusion defects were interpreted qualitatively by 2 blinded observers and were correlated with x-ray angiographic stenoses ≥50%. The prevalence of CAD was 56%. In the per-patient analysis, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of SW-CG-HYPR was 96% (95% confidence interval 82% to 100%), 82% (95% confidence interval 60% to 95%), 87% (95% confidence interval 70% to 96%), 95% (95% confidence interval 74% to100%), and 90% (95% confidence interval 82% to 98%), respectively. In the per-vessel analysis, the corresponding values were 98% (95% confidence interval 91% to 100%), 89% (95% confidence interval 80% to 94%), 86% (95% confidence interval 76% to 93%), 99% (95% confidence interval 93% to 100%), and 93% (95% confidence interval 89% to 97%), respectively. In conclusion, myocardial perfusion MRI using SW-CG-HYPR allows whole left ventricular coverage and high resolution and has high diagnostic accuracy in patients with suspected CAD. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Effect of beam hardening on transmural myocardial perfusion quantification in myocardial CT imaging

    NASA Astrophysics Data System (ADS)

    Fahmi, Rachid; Eck, Brendan L.; Levi, Jacob; Fares, Anas; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    The detection of subendocardial ischemia exhibiting an abnormal transmural perfusion gradient (TPG) may help identify ischemic conditions due to micro-vascular dysfunction. We evaluated the effect of beam hardening (BH) artifacts on TPG quantification using myocardial CT perfusion (CTP). We used a prototype spectral detector CT scanner (Philips Healthcare) to acquire dynamic myocardial CTP scans in a porcine ischemia model with partial occlusion of the left anterior descending (LAD) coronary artery guided by pressure wire-derived fractional flow reserve (FFR) measurements. Conventional 120 kVp and 70 keV projection-based mono-energetic images were reconstructed from the same projection data and used to compute myocardial blood flow (MBF) using the Johnson-Wilson model. Under moderate LAD occlusion (FFR~0.7), we used three 5 mm short axis slices and divided the myocardium into three LAD segments and three remote segments. For each slice and each segment, we characterized TPG as the mean "endo-to-epi" transmural flow ratio (TFR). BH-induced hypoenhancement on the ischemic anterior wall at 120 kVp resulted in significantly lower mean TFR value as compared to the 70 keV TFR value (0.29+/-0.01 vs. 0.55+/-0.01 p<1e-05). No significant difference was measured between 120 kVp and 70 keV mean TFR values on segments moderately affected or unaffected by BH. In the entire ischemic LAD territory, 120 kVp mean endocardial flow was significantly reduced as compared to mean epicardial flow (15.80+/-10.98 vs. 40.85+/-23.44 ml/min/100g; p<1e-04). At 70 keV, BH was effectively minimized resulting in mean endocardial MBF of 40.85+/-15.3407 ml/min/100g vs. 74.09+/-5.07 ml/min/100g (p=0.0054) in the epicardium. We also found that BH artifact in the conventional 120 kVp images resulted in falsely reduced MBF measurements even under non-ischemic conditions.

  4. Automated three-dimensional quantification of myocardial perfusion and brain SPECT.

    PubMed

    Slomka, P J; Radau, P; Hurwitz, G A; Dey, D

    2001-01-01

    To allow automated and objective reading of nuclear medicine tomography, we have developed a set of tools for clinical analysis of myocardial perfusion tomography (PERFIT) and Brain SPECT/PET (BRASS). We exploit algorithms for image registration and use three-dimensional (3D) "normal models" for individual patient comparisons to composite datasets on a "voxel-by-voxel basis" in order to automatically determine the statistically significant abnormalities. A multistage, 3D iterative inter-subject registration of patient images to normal templates is applied, including automated masking of the external activity before final fit. In separate projects, the software has been applied to the analysis of myocardial perfusion SPECT, as well as brain SPECT and PET data. Automatic reading was consistent with visual analysis; it can be applied to the whole spectrum of clinical images, and aid physicians in the daily interpretation of tomographic nuclear medicine images.

  5. Association between left ventricular perfusion defects and myocardial deformation indexes in heart transplantation recipients.

    PubMed

    D'Andrea, Antonello; De Rimini, Maria Luisa; America, Raffaella; Cirillo, Chiara; Riegler, Lucia; Limongelli, Giuseppe; D'Alto, Michele; Salerno, Gemma; Maiello, Ciro; Muto, Pietro; Russo, Maria Giovanna; Calabrò, Raffaele; Bossone, Eduardo; Pacileo, Giuseppe

    2017-10-01

    The aim of the study was to analyze possible correlations between strain echocardiography (STE) and PET myocardial perfusion in a population of heart transplantation (HTx) recipients showing preserved left ventricular (LV) ejection fraction. By STE, LV global longitudinal strain (LV GLS) was lower in HTx. PET showed no transient or chronic ischemia in 83 of 115 HTx (73%). Fixed perfusion defects were observed in 17% of HTx and reversible ischemia in 10%. Significant coronary stenosis was observed only in 10 cases. GLS was independently associated with age at HTx and fixed perfusion defects (HR 0.41; P<.001). Such relationships underline STE ability to early identify HTx pts with subclinical myocardial dysfunction during long-term follow-up. © 2017, Wiley Periodicals, Inc.

  6. A novel gallium bisaminothiolate complex as a myocardial perfusion imaging agent

    PubMed Central

    Plössl, Karl; Chandra, Rajesh; Qu, Wenchao; Lieberman, Brian P.; Kung, Mei-Ping; Zhou, Rong; Huang, Bin; Kung, Hank F.

    2010-01-01

    The development of new myocardial perfusion imaging agents for positron emission tomography (PET) may improve the resolution and quantitation of changes in regional myocardial perfusion measurement. It is known that a 68Ge/68Ga generator can provide a convenient source of PET tracers because of the long physical half-life of 68Ge (271 days). A new ligand, 7,8-dithia-16,24-diaza-trispiro[5.2.5.2.5.3] pentacosa-15,24-diene, which consists of a N2S2-chelating core incorporated into three cyclohexyl rings, was prepared. To test feasibility and potential utility, the N2S2 ligand was successfully labeled and tested with 67Ga (half-life=3.26 day; γ=93.3, 184.6 and 300.2 keV), which showed >92% radiochemical purity. The corresponding “cold” Ga complex was synthesized, and its structure containing a pyramidal N2S2 chloride core was elucidated with X-ray crystallography. In vivo biodistribution of this novel 67Ga complex, evaluated in normal rats, exhibited excellent heart uptake and retention, with 2.1% and 0.9% initial dose/organ at 2 and 60 min, respectively, after an intravenous injection. Autoradiography was performed in normal rats and in rats that had the left anterior descending coronary artery permanently ligated surgically. Autoradiography showed an even uptake of activity in the normal heart, and there was a distinctively lower uptake in the damaged side of the surgically modified heart. In conclusion, the new N2S2 ligand was readily prepared and labeled with radioactive 67Ga. Biodistribution in rats revealed high initial heart uptake and relatively high retention reflecting regional myocardial perfusion. PMID:18158947

  7. Beam hardening artifact reduction using dual energy computed tomography: implications for myocardial perfusion studies

    PubMed Central

    Carrascosa, Patricia; Cipriano, Silvina; De Zan, Macarena; Deviggiano, Alejandro; Capunay, Carlos; Cury, Ricardo C.

    2015-01-01

    Background Myocardial computed tomography perfusion (CTP) using conventional single energy (SE) imaging is influenced by the presence of beam hardening artifacts (BHA), occasionally resembling perfusion defects and commonly observed at the left ventricular posterobasal wall (PB). We therefore sought to explore the ability of dual energy (DE) CTP to attenuate the presence of BHA. Methods Consecutive patients without history of coronary artery disease who were referred for computed tomography coronary angiography (CTCA) due to atypical chest pain and a normal stress-rest SPECT and had absence or mild coronary atherosclerosis constituted the study population. The study group was acquired using DE and the control group using SE imaging. Results Demographical characteristics were similar between groups, as well as the heart rate and the effective radiation dose. Myocardial signal density (SD) levels were evaluated in 280 basal segments among the DE group (140 PB segments for each energy level from 40 to 100 keV; and 140 reference segments), and in 40 basal segments (at the same locations) among the SE group. Among the DE group, myocardial SD levels and myocardial SD ratio evaluated at the reference segment were higher at low energy levels, with significantly lower SD levels at increasing energy levels. Myocardial signal-to-noise ratio was not significantly influenced by the energy level applied, although 70 keV was identified as the energy level with the best overall signal-to-noise ratio. Significant differences were identified between the PB segment and the reference segment among the lower energy levels, whereas at ≥70 keV myocardial SD levels were similar. Compared to DE reconstructions at the best energy level (70 keV), SE acquisitions showed no significant differences overall regarding myocardial SD levels among the reference segments. Conclusions BHA that influence the assessment of myocardial perfusion can be attenuated using DE at 70 keV or higher. PMID

  8. Effects of pimobendan on myocardial perfusion and pulmonary transit time in dogs with myxomatous mitral valve disease: a pilot study.

    PubMed

    Apple, S M; Menciotti, G; Braz-Ruivo, L; Crosara, S; Häggström, J; Borgarelli, M

    2016-09-01

    To describe pulmonary transit time (nPTT) and myocardial perfusion (nMP) normalised to heart rate in dogs with stable ACVIM stage C myxomatous mitral valve disease (MMVD) and to assess short-term effects of pimobendan on these variables. We hypothesised that nPTT and nMP would increase in dogs with MMVD compared with normal dogs. Additionally, we hypothesised that treatment with pimobendan would decrease nMP and nPTT in dogs with MMVD. Prospective, single-blind study involving 6 normal dogs and 12 dogs with MMVD. Dogs with MMVD were treated with enalapril and furosemide for at least 1 month prior to examination. All dogs underwent standard and contrast echocardiographic examinations at the beginning of the study (T0). At this time, MMVD dogs were randomly assigned to receive either pimobendan (0.4-0.6 mg/kg) or not. All dogs with MMVD were re-evaluated by standard and contrast echocardiography after 1 week (T1) and nPTT and nMP were measured. nPTT was significantly increased in dogs with MMVD (P = 0.0063), compared with normal dogs. It was significantly decreased at T1 in dogs receiving pimobendan (P = 0.0250). The nMP was not significantly different in dogs with MMVD, compared with healthy dogs (P = 0.2552), and it was not significantly different at T1 in the treatment group (P = 0.8798). Contrast echocardiography was a valid, complementary tool for echocardiographic analysis of dogs with MMVD. Pimobendan decreased nPTT in dogs affected by MMVD. Myocardial perfusion was not different in dogs with severe MMVD. © 2016 Australian Veterinary Association.

  9. Kinetics and dosimetry of thallium-201 in human testes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rao, D.V.; Shepstone, B.J.; Wilkins, H.B.

    Thallous chloride ({sup 201}Tl) is a well-known imaging agent. It has been shown to accumulate in the testes. In view of this, the testicular kinetics of {sup 201}Tl is investigated in humans and the absorbed dose to the organ calculated. Thallous chloride {sup 201}Tl was injected intravenously into four patients for myocardial perfusion studies. After clinical evaluation, the testicular uptake and clearance of {sup 201}Tl were monitored for about 1 wk using a gamma camera. Testicular uptake of {sup 201}Tl was rapid with a mean biological uptake half-time of 0.67 hr and mean biological clearance half-time of 280 hr. Themore » mean maximum testicular uptake of {sup 201}Tl was about 0.4% of the injected activity. These data were utilized to calculate the average absorbed dose to the testes. The absorbed dose to the testes was calculated to be 3.5 x 10{sup {minus}4} Gy/MBq (1.3 rad/mCi) of injected activity. When the relative biological effectiveness of the Auger emitter {sup 201}Tl is taken into account, the equivalent dose to the testes is 9.5 x 10{sup {minus}4} Sv/MBq (3.5 rem/mCi). 14 refs., 1 fig., 2 tabs.« less

  10. Quantitative myocardial perfusion from static cardiac and dynamic arterial CT

    NASA Astrophysics Data System (ADS)

    Bindschadler, Michael; Branch, Kelley R.; Alessio, Adam M.

    2018-05-01

    Quantitative myocardial blood flow (MBF) estimation by dynamic contrast enhanced cardiac computed tomography (CT) requires multi-frame acquisition of contrast transit through the blood pool and myocardium to inform the arterial input and tissue response functions. Both the input and the tissue response functions for the entire myocardium are sampled with each acquisition. However, the long breath holds and frequent sampling can result in significant motion artifacts and relatively high radiation dose. To address these limitations, we propose and evaluate a new static cardiac and dynamic arterial (SCDA) quantitative MBF approach where (1) the input function is well sampled using either prediction from pre-scan timing bolus data or measured from dynamic thin slice ‘bolus tracking’ acquisitions, and (2) the whole-heart tissue response data is limited to one contrast enhanced CT acquisition. A perfusion model uses the dynamic arterial input function to generate a family of possible myocardial contrast enhancement curves corresponding to a range of MBF values. Combined with the timing of the single whole-heart acquisition, these curves generate a lookup table relating myocardial contrast enhancement to quantitative MBF. We tested the SCDA approach in 28 patients that underwent a full dynamic CT protocol both at rest and vasodilator stress conditions. Using measured input function plus single (enhanced CT only) or plus double (enhanced and contrast free baseline CT’s) myocardial acquisitions yielded MBF estimates with root mean square (RMS) error of 1.2 ml/min/g and 0.35 ml/min/g, and radiation dose reductions of 90% and 83%, respectively. The prediction of the input function based on timing bolus data and the static acquisition had an RMS error compared to the measured input function of 26.0% which led to MBF estimation errors greater than threefold higher than using the measured input function. SCDA presents a new, simplified approach for quantitative

  11. Qualitative evaluation of coronary flow during anesthetic induction using thallium-201 perfusion scans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kleinman, B.; Henkin, R.E.; Glisson, S.N.

    Qualitative distribution of coronary flow using thallium-201 perfusion scans immediately postintubation was studied in 22 patients scheduled for elective coronary artery bypass surgery. Ten patients received a thiopental (4 mg/kg) and halothane induction. Twelve patients received a fentanyl (100 micrograms/kg) induction. Baseline thallium-201 perfusion scans were performed 24 h prior to surgery. These scans were compared with the scans performed postintubation. A thallium-positive scan was accepted as evidence of relative hypoperfusion. Baseline hemodynamic and ECG data were obtained prior to induction of anesthesia. These data were compared with the data obtained postintubation. Ten patients developed postintubation thallium-perfusion scan defects (thallium-positivemore » scan), even though there was no statistical difference between their baseline hemodynamics and hemodynamics at the time of intubation. There was no difference in the incidence of thallium-positive scans between those patients anesthetized by fentanyl and those patients anesthetized with thiopental-halothane. The authors conclude that relative hypoperfusion, and possibly ischemia, occurred in 45% of patients studied, despite stable hemodynamics, and that the incidence of these events was the same with two different anesthetic techniques.« less

  12. Time-resolved 3D pulmonary perfusion MRI: comparison of different k-space acquisition strategies at 1.5 and 3 T.

    PubMed

    Attenberger, Ulrike I; Ingrisch, Michael; Dietrich, Olaf; Herrmann, Karin; Nikolaou, Konstantin; Reiser, Maximilian F; Schönberg, Stefan O; Fink, Christian

    2009-09-01

    Time-resolved pulmonary perfusion MRI requires both high temporal and spatial resolution, which can be achieved by using several nonconventional k-space acquisition techniques. The aim of this study is to compare the image quality of time-resolved 3D pulmonary perfusion MRI with different k-space acquisition techniques in healthy volunteers at 1.5 and 3 T. Ten healthy volunteers underwent contrast-enhanced time-resolved 3D pulmonary MRI on 1.5 and 3 T using the following k-space acquisition techniques: (a) generalized autocalibrating partial parallel acquisition (GRAPPA) with an internal acquisition of reference lines (IRS), (b) GRAPPA with a single "external" acquisition of reference lines (ERS) before the measurement, and (c) a combination of GRAPPA with an internal acquisition of reference lines and view sharing (VS). The spatial resolution was kept constant at both field strengths to exclusively evaluate the influences of the temporal resolution achieved with the different k-space sampling techniques on image quality. The temporal resolutions were 2.11 seconds IRS, 1.31 seconds ERS, and 1.07 VS at 1.5 T and 2.04 seconds IRS, 1.30 seconds ERS, and 1.19 seconds VS at 3 T.Image quality was rated by 2 independent radiologists with regard to signal intensity, perfusion homogeneity, artifacts (eg, wrap around, noise), and visualization of pulmonary vessels using a 3 point scale (1 = nondiagnostic, 2 = moderate, 3 = good). Furthermore, the signal-to-noise ratio in the lungs was assessed. At 1.5 T the lowest image quality (sum score: 154) was observed for the ERS technique and the highest quality for the VS technique (sum score: 201). In contrast, at 3 T images acquired with VS were hampered by strong artifacts and image quality was rated significantly inferior (sum score: 137) compared with IRS (sum score: 180) and ERS (sum score: 174). Comparing 1.5 and 3 T, in particular the overall rating of the IRS technique (sum score: 180) was very similar at both field

  13. Panic attack triggering myocardial ischemia documented by myocardial perfusion imaging study. A case report

    PubMed Central

    2012-01-01

    Background Chest pain, a key element in the investigation of coronary artery disease is often regarded as a benign prognosis when present in panic attacks. However, panic disorder has been suggested as an independent risk factor for long-term prognosis of cardiovascular diseases and a trigger of acute myocardial infarction. Objective Faced with the extreme importance in differentiate from ischemic to non-ischemic chest pain, we report a case of panic attack induced by inhalation of 35% carbon dioxide triggering myocardial ischemia, documented by myocardial perfusion imaging study. Discussion Panic attack is undoubtedly a strong component of mental stress. Patients with coronary artery disease may present myocardial ischemia in mental stress response by two ways: an increase in coronary vasomotor tone or a sympathetic hyperactivity leading to a rise in myocardial oxygen consumption. Coronary artery spasm was presumed to be present in cases of cardiac ischemia linked to panic disorder. Possibly the carbon dioxide challenge test could trigger myocardial ischemia by the same mechanisms. Conclusion The use of mental stress has been suggested as an alternative method for myocardial ischemia investigation. Based on translational medicine objectives the use of CO2 challenge followed by Sestamibi SPECT could be a useful method to allow improved application of research-based knowledge to the medical field, specifically at the interface of PD and cardiovascular disease. PMID:22999016

  14. Panic attack triggering myocardial ischemia documented by myocardial perfusion imaging study. A case report.

    PubMed

    Soares-Filho, Gastão Luiz Fonseca; Mesquita, Claudio Tinoco; Mesquita, Evandro Tinoco; Arias-Carrión, Oscar; Machado, Sergio; González, Manuel Menéndez; Valença, Alexandre Martins; Nardi, Antonio Egidio

    2012-09-21

    Chest pain, a key element in the investigation of coronary artery disease is often regarded as a benign prognosis when present in panic attacks. However, panic disorder has been suggested as an independent risk factor for long-term prognosis of cardiovascular diseases and a trigger of acute myocardial infarction. Faced with the extreme importance in differentiate from ischemic to non-ischemic chest pain, we report a case of panic attack induced by inhalation of 35% carbon dioxide triggering myocardial ischemia, documented by myocardial perfusion imaging study. Panic attack is undoubtedly a strong component of mental stress. Patients with coronary artery disease may present myocardial ischemia in mental stress response by two ways: an increase in coronary vasomotor tone or a sympathetic hyperactivity leading to a rise in myocardial oxygen consumption. Coronary artery spasm was presumed to be present in cases of cardiac ischemia linked to panic disorder. Possibly the carbon dioxide challenge test could trigger myocardial ischemia by the same mechanisms. The use of mental stress has been suggested as an alternative method for myocardial ischemia investigation. Based on translational medicine objectives the use of CO2 challenge followed by Sestamibi SPECT could be a useful method to allow improved application of research-based knowledge to the medical field, specifically at the interface of PD and cardiovascular disease.

  15. Evaluation of heart perfusion in patients with acute myocardial infarction using dynamic contrast-enhanced magnetic resonance imaging.

    PubMed

    Nielsen, Gitte; Fritz-Hansen, Thomas; Dirks, Christina G; Jensen, Gorm B; Larsson, Henrik B W

    2004-09-01

    To investigate the diagnostic ability of quantitative magnetic resonance imaging (MRI) heart perfusion in acute heart patients, a fast, multislice dynamic contrast-enhanced MRI sequence was applied to patients with acute myocardial infarction. Seven patients with acute transmural myocardial infarction were studied using a Turbo-fast low angle shot (FLASH) MRI sequence to monitor the first pass of an extravascular contrast agent (CA), gadolinium diethylene triamine pentaacetic acid (Gd-DTPA). Quantitation of perfusion, expressed as Ki (mL/100 g/minute), in five slices, each having 60 sectors, provided an estimation of the severity and extent of the perfusion deficiency. Reperfusion was assessed both by noninvasive criteria and by coronary angiography (CAG). The Ki maps clearly delineated the infarction in all patients. Thrombolytic treatment was clearly beneficial in one case, but had no effect in the two other cases. Over the time-course of the study, normal perfusion values were not reestablished following thrombolytic treatment in all cases investigated. This study shows that quantitative MRI perfusion values can be obtained from acutely ill patients following acute myocardial infarction. The technique provides information on both the volume and severity of affected myocardial tissue, enabling the power of treatment regimes to be assessed objectively, and this approach should aid individual patient stratification and prognosis. Copyright 2004 Wiley-Liss, Inc.

  16. Review: comparison of PET rubidium-82 with conventional SPECT myocardial perfusion imaging

    PubMed Central

    Ghotbi, Adam A; Kjær, Andreas; Hasbak, Philip

    2014-01-01

    Nuclear cardiology has for many years been focused on gamma camera technology. With ever improving cameras and software applications, this modality has developed into an important assessment tool for ischaemic heart disease. However, the development of new perfusion tracers has been scarce. While cardiac positron emission tomography (PET) so far largely has been limited to centres with on-site cyclotron, recent developments with generator produced perfusion tracers such as rubidium-82, as well as an increasing number of PET scanners installed, may enable a larger patient flow that may supersede that of gamma camera myocardial perfusion imaging. PMID:24028171

  17. Computerized study with 201T1 of the cold thyroid node.

    PubMed

    Palermo, F; Saitta, B; Coghetto, F; Tiberio, M; Caldato, L

    1982-02-01

    Because of its physical and potassium-metabolic characteristics 201T1 is more suitable than 131Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behavior for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 microCi/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential 201T1 uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different 201T1 kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular disappearance-index.

  18. Routine Clinical Quantitative Rest Stress Myocardial Perfusion for Managing Coronary Artery Disease: Clinical Relevance of Test-Retest Variability.

    PubMed

    Kitkungvan, Danai; Johnson, Nils P; Roby, Amanda E; Patel, Monika B; Kirkeeide, Richard; Gould, K Lance

    2017-05-01

    Positron emission tomography (PET) quantifies stress myocardial perfusion (in cc/min/g) and coronary flow reserve to guide noninvasively the management of coronary artery disease. This study determined their test-retest precision within minutes and daily biological variability essential for bounding clinical decision-making or risk stratification based on low flow ischemic thresholds or follow-up changes. Randomized trials of fractional flow reserve-guided percutaneous coronary interventions established an objective, quantitative, outcomes-driven standard of physiological stenosis severity. However, pressure-derived fractional flow reserve requires invasive coronary angiogram and was originally validated by comparison to noninvasive PET. The time course and test-retest precision of serial quantitative rest-rest and stress-stress global myocardial perfusion by PET within minutes and days apart in the same patient were compared in 120 volunteers undergoing serial 708 quantitative PET perfusion scans using rubidium 82 (Rb-82) and dipyridamole stress with a 2-dimensional PET-computed tomography scanner (GE DST 16) and University of Texas HeartSee software with our validated perfusion model. Test-retest methodological precision (coefficient of variance) for serial quantitative global myocardial perfusion minutes apart is ±10% (mean ΔSD at rest ±0.09, at stress ±0.23 cc/min/g) and for days apart is ±21% (mean ΔSD at rest ±0.2, at stress ±0.46 cc/min/g) reflecting added biological variability. Global myocardial perfusion at 8 min after 4-min dipyridamole infusion is 10% higher than at standard 4 min after dipyridamole. Test-retest methodological precision of global PET myocardial perfusion by serial rest or stress PET minutes apart is ±10%. Day-to-different-day biological plus methodological variability is ±21%, thereby establishing boundaries of variability on physiological severity to guide or follow coronary artery disease management. Maximum stress

  19. Synthesis of fluorine-18 labeled rhodamine B: A potential PET myocardial perfusion imaging agent

    PubMed Central

    Heinrich, Tobias K.; Gottumukkala, Vijay; Snay, Erin; Dunning, Patricia; Fahey, Frederic H; Treves, S. Ted; Packard, Alan B.

    2009-01-01

    There is considerable interest in developing an 18F-labeled PET myocardial perfusion agent. Rhodamine dyes share several properties with 99mTc-MIBI, the most commonly used single-photon myocardial perfusion agent, suggesting that an 18F-labeled rhodamine dye might prove useful for this application. In addition to being lipophilic cations, like 99mTc-MIBI, rhodamine dyes are known to accumulate in the myocardium and are substrates for Pgp, the protein implicated in MDR1 multidrug resistance. As the first step in determining whether 18F-labeled rhodamines might be useful as myocardial perfusion agents for PET, our objective was to develop synthetic methods for preparing the 18F-labeled compounds so that they could be evaluated in vivo. Rhodamine B was chosen as the prototype compound for development of the synthesis because the ethyl substituents on the amine moieties of rhodamine B protect them from side reactions, thus eliminating the need to include (and subsequently remove) protecting groups. The 2′-[18F]fluoroethyl ester of rhodamine B was synthesized by heating rhodamine B lactone with [18F]fluoroethyltosylate in acetonitrile at 165°C for 30 min.using [18F]fluoroethyl tosylate, which was prepared by the reaction of ethyleneglycol ditosylate with Kryptofix 2.2.2, K2CO3, and [18F]NaF in acetonitrile for 10 min. at 90°C. The product was purified by semi-preparative HPLC to produce the 2′-[18F]-fluoroethylester in >97% radiochemical purity with a specific activity of 1.3 GBq/μmol, an isolated decay corrected yield of 35%, and a total synthesis time of 90 min. PMID:19783150

  20. Optimization of Rb-82 PET acquisition and reconstruction protocols for myocardial perfusion defect detection

    NASA Astrophysics Data System (ADS)

    Tang, Jing; Rahmim, Arman; Lautamäki, Riikka; Lodge, Martin A.; Bengel, Frank M.; Tsui, Benjamin M. W.

    2009-05-01

    The purpose of this study is to optimize the dynamic Rb-82 cardiac PET acquisition and reconstruction protocols for maximum myocardial perfusion defect detection using realistic simulation data and task-based evaluation. Time activity curves (TACs) of different organs under both rest and stress conditions were extracted from dynamic Rb-82 PET images of five normal patients. Combined SimSET-GATE Monte Carlo simulation was used to generate nearly noise-free cardiac PET data from a time series of 3D NCAT phantoms with organ activities modeling different pre-scan delay times (PDTs) and total acquisition times (TATs). Poisson noise was added to the nearly noise-free projections and the OS-EM algorithm was applied to generate noisy reconstructed images. The channelized Hotelling observer (CHO) with 32× 32 spatial templates corresponding to four octave-wide frequency channels was used to evaluate the images. The area under the ROC curve (AUC) was calculated from the CHO rating data as an index for image quality in terms of myocardial perfusion defect detection. The 0.5 cycle cm-1 Butterworth post-filtering on OS-EM (with 21 subsets) reconstructed images generates the highest AUC values while those from iteration numbers 1 to 4 do not show different AUC values. The optimized PDTs for both rest and stress conditions are found to be close to the cross points of the left ventricular chamber and myocardium TACs, which may promote an individualized PDT for patient data processing and image reconstruction. Shortening the TATs for <~3 min from the clinically employed acquisition time does not affect the myocardial perfusion defect detection significantly for both rest and stress studies.

  1. TU-G-204-03: Dynamic CT Myocardial Perfusion Measurement Using First Pass Analysis and Maximum Slope Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hubbard, L; Ziemer, B; Sadeghi, B

    Purpose: To evaluate the accuracy of dynamic CT myocardial perfusion measurement using first pass analysis (FPA) and maximum slope models. Methods: A swine animal model was prepared by percutaneous advancement of an angioplasty balloon into the proximal left anterior descending (LAD) coronary artery to induce varying degrees of stenosis. Maximal hyperaemia was achieved in the LAD with an intracoronary adenosine drip (240 µg/min). Serial microsphere and contrast (370 mg/mL iodine, 30 mL, 5mL/s) injections were made over a range of induced stenoses, and dynamic imaging was performed using a 320-row CT scanner at 100 kVp and 200 mA. The FPAmore » CT perfusion technique was used to make vessel-specific myocardial perfusion measurements. CT perfusion measurements using the FPA and maximum slope models were validated using colored microspheres as the reference gold standard. Results: Perfusion measurements using the FPA technique (P-FPA) showed good correlation with minimal offset when compared to perfusion measurements using microspheres (P- Micro) as the reference standard (P -FPA = 0.96 P-Micro + 0.05, R{sup 2} = 0.97, RMSE = 0.19 mL/min/g). In contrast, the maximum slope model technique (P-MS) was shown to underestimate perfusion when compared to microsphere perfusion measurements (P-MS = 0.42 P -Micro −0.48, R{sup 2} = 0.94, RMSE = 3.3 mL/min/g). Conclusion: The results indicate the potential for significant improvements in accuracy of dynamic CT myocardial perfusion measurement using the first pass analysis technique as compared with the standard maximum slope model.« less

  2. Sex and age differences in the association of heart rate responses to adenosine and myocardial ischemia in patients undergoing myocardial perfusion imaging.

    PubMed

    Gebhard, Catherine; Messerli, Michael; Lohmann, Christine; Treyer, Valerie; Bengs, Susan; Benz, Dominik C; Giannopoulos, Andreas A; Kudura, Ken; von Felten, Elia; Schwyzer, Moritz; Gaemperli, Oliver; Gräni, Christoph; Pazhenkottil, Aju P; Buechel, Ronny R; Kaufmann, Philipp A

    2018-04-23

    In light of growing cardiovascular mortality rates observed in young women, sexual dimorphism in cardiac autonomic nervous control is gaining increasing attention. Heart rate responses to adenosine mirror autonomic activity and may carry important prognostic information. Hemodynamic changes during adenosine stress were retrospectively analysed in a propensity-matched cohort of 1932 consecutive patients undergoing myocardial perfusion single-photon-emission computed tomography (MPI-SPECT). Heart rate (HR) and systolic blood pressure (SBP) increased during adenosine infusion (P < 0.001). The increase in SBP and HR (heart rate reserve, HRR), was significantly more pronounced in women compared with men (P < 0.05). Patients ≤ 55 years had a higher HRR compared with patients > 55 years (46.8% vs 37.5%, P = 0.015). Women ≤ 55 years with a reversible perfusion defect on MPI-SPECT exhibited the highest HRR (89.2%), while age-matched men showed a blunted HR response to adenosine (26.4%, P = 0.01). Accordingly, age and an interaction term of female sex and increased HRR were identified as significant predictors of myocardial ischemia in a multiple regression analysis (OR 1.4, 95% CI 1.02-1.9, P = 0.038). HRR during adenosine infusion is influenced by age and sex. Our data suggest a stronger, sympathetic-driven, hemodynamic response to adenosine in younger women with myocardial ischemia.

  3. [Diagnosis of myocardial infarction by cine MR imaging--a comparative study with thallium-201 myocardial SPECT].

    PubMed

    Shiozaki, H

    1993-01-25

    The usefulness of cine magnetic resonance (MR) imaging was evaluated in 41 patients with acute (4 cases), subacute (21 cases) and chronic (16 cases) myocardial infarctions on the basis of the findings of thallium-201 myocardial SPECT. The overall rate of diagnostic accordance between cine MR imaging and SPECT was 85.0% (408/480). It was highest at the middle of the left ventricle (89.0%, 146/164) and lowest at the base (82.7%, 129/156). Measurement of wall thickness using the images printed on films was possible in 87.1% of segments (418/480). There was a significant difference in end-diastolic wall thickness and %-thickening between the infarcted and non-infarcted sites except for the base of the left ventricle. However, diastolic wall thinning was not remarkable in acute cases of less than one week after onset. In these cases %-thickening may be useful. Partial volume averaging on MR imaging and the inaccuracy of SPECT findings at the base also made meaningful comparison difficult. The most important diagnostic findings of myocardial infarction on cine MR imaging were end-diastolic wall thinning and abnormal motion such as akinesis and dyskinesis. It is concluded that cine MR imaging is a useful noninvasive examination method for evaluating the status of cardiac function in myocardial infarction.

  4. 3D image fusion of whole-heart dynamic cardiac MR perfusion and late gadolinium enhancement: Intuitive delineation of myocardial hypoperfusion and scar.

    PubMed

    von Spiczak, Jochen; Mannil, Manoj; Kozerke, Sebastian; Alkadhi, Hatem; Manka, Robert

    2018-03-30

    Since patients with myocardial hypoperfusion due to coronary artery disease (CAD) with preserved viability are known to benefit from revascularization, accurate differentiation of hypoperfusion from scar is desirable. To develop a framework for 3D fusion of whole-heart dynamic cardiac MR perfusion and late gadolinium enhancement (LGE) to delineate stress-induced myocardial hypoperfusion and scar. Prospective feasibility study. Sixteen patients (61 ± 14 years, two females) with known/suspected CAD. 1.5T (nine patients); 3.0T (seven patients); whole-heart dynamic 3D cardiac MR perfusion (3D-PERF, under adenosine stress); 3D LGE inversion recovery sequences (3D-SCAR). A software framework was developed for 3D fusion of 3D-PERF and 3D-SCAR. Computation steps included: 1) segmentation of the left ventricle in 3D-PERF and 3D-SCAR; 2) semiautomatic thresholding of perfusion/scar data; 3) automatic calculation of ischemic/scar burden (ie, pathologic relative to total myocardium); 4) projection of perfusion/scar values onto artificial template of the left ventricle; 5) semiautomatic coregistration to an exemplary heart contour easing 3D orientation; and 6) 3D rendering of the combined datasets using automatically defined color tables. All tasks were performed by two independent, blinded readers (J.S. and R.M.). Intraclass correlation coefficients (ICC) for determining interreader agreement. Image acquisition, postprocessing, and 3D fusion were feasible in all cases. In all, 10/16 patients showed stress-induced hypoperfusion in 3D-PERF; 8/16 patients showed LGE in 3D-SCAR. For 3D-PERF, semiautomatic thresholding was possible in all patients. For 3D-SCAR, automatic thresholding was feasible where applicable. Average ischemic burden was 11 ± 7% (J.S.) and 12 ± 7% (R.M.). Average scar burden was 8 ± 5% (J.S.) and 7 ± 4% (R.M.). Interreader agreement was excellent (ICC for 3D-PERF = 0.993, for 3D-SCAR = 0.99). 3D fusion of 3D-PERF and 3D

  5. CT myocardial perfusion imaging: current status and future perspectives.

    PubMed

    Yang, Dong Hyun; Kim, Young-Hak

    2017-07-01

    Computed tomography myocardial perfusion (CTP) combined with coronary computed tomography angiography (CCTA) may constitute a "1-stop shop" for the noninvasive diagnosis of hemodynamically significant coronary stenosis during a single CT examination. CTP shows high diagnostic performance and provides incremental value over CCTA for the detection of hemodynamically significant coronary stenosis in patients with a high Agatston calcium score or coronary artery stents. Future studies should determine the optimal protocol and clinical value of CTP for guiding revascularization strategy and prognostication. In this article, we review the current status and future perspectives of CTP, focusing on technical considerations, clinical applications, and future research topics.

  6. Sex differences in absolute myocardial perfusion. Non-invasive H2(15)O-PET in young healthy adults.

    PubMed

    Range, Felix T; Kies, Peter; Schäfers, Klaus P; Breithardt, Günter; Schober, Otmar; Wichter, Thomas; Schäfers, Michael A

    2016-09-26

    To investigate sex differences in myocardial perfusion especially in healthy individuals since former studies are rare and findings are controversial. Participants, methods: 26 subjects were enrolled: 16 healthy women (age: 34 ±7 years) were compared with 10 healthy men (age: 34 ± 3 years; p = ns). Myocardial blood flow (MBF) and coronary vascular resistance (CVR) were quantified at rest, during adenosine infusion and cold-pressor-testing, using positron emission tomography and radioactive-labelled water (H2(15)O-PET). Women showed higher MBF than men at rest (1.10 ± 0.18 vs. 0.85 ± 0.20 ml/min/ml; p = 0.003) and cold-stress (1.39 ± 0.38 vs. 1.06 ± 0.28 ml/min/ml; p = 0.026). Corrected for rate-pressure-product, baseline findings maintained significance (1.41 ± 0.33 vs. 1.16 ± 0.19 ml/min/ml; p = 0.024). CVR was lower in women at baseline (81 ± 14 vs. 107 ± 22 mmHg*ml(-1)*min*ml; p = 0.006) and during cold-pressor-testing (71 ± 17 vs. 91 ± 20 mmHg*ml(-1)*min*ml; p = 0.013). Under adenosine neither maximal MBF (4.06 ± 1.0 vs. 3.91 ± 0.88 ml/min/ml; p = ns) nor coronary flow reserve (3.07 ± 1.12 vs. 3.44 ± 0.92; p = ns) nor CVR (24 ± 8 vs. 24 ± 6 mmHg*ml(-1)*min*ml; p = ns) showed sex-related differences. Women show higher myocardial perfusion and lower coronary vascular resistance than men in physiologic states. Maximum perfusion and vasodilation under adenosine are not sex-specific.

  7. Parametric techniques for characterizing myocardial tissue by magnetic resonance imaging (part 1): T1 mapping.

    PubMed

    Perea Palazón, R J; Ortiz Pérez, J T; Prat González, S; de Caralt Robira, T M; Cibeira López, M T; Solé Arqués, M

    2016-01-01

    The development of myocardial fibrosis is a common process in the appearance of ventricular dysfunction in many heart diseases. Magnetic resonance imaging makes it possible to accurately evaluate the structure and function of the heart, and its role in the macroscopic characterization of myocardial fibrosis by late enhancement techniques has been widely validated clinically. Recent studies have demonstrated that T1-mapping techniques can quantify diffuse myocardial fibrosis and the expansion of the myocardial extracellular space in absolute terms. However, further studies are necessary to validate the usefulness of this technique in the early detection of tissue remodeling at a time when implementing early treatment would improve a patient's prognosis. This article reviews the state of the art for T1 mapping of the myocardium, its clinical applications, and its limitations. Copyright © 2016 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  8. Caffeine reduces dipyridamole-induced myocardial ischemia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smits, P.; Aengevaeren, W.R.; Corstens, F.H.

    1989-10-01

    The mechanism of action of coronary vasodilation after dipyridamole may be based on inhibition of cellular uptake of circulating endogenous adenosine. Since caffeine has been reported to be a competitive antagonist of adenosine we studied the effect of caffeine on the outcome of dipiridamole-{sup 201}Tl cardiac imaging in one patient. During caffeine abstinence dipyridamole induced myocardial ischemia with down-slope ST depressions on the ECG, and reversible perfusion defects on the scintigrams. When the test was repeated 1 wk later on similar conditions, but now shortly after infusion of caffeine (4 mg/kg), the ECG showed nodepressions, and the scintigrams only slightmore » signs of ischemia. We conclude that when caffeine abstinence is not sufficient, the widespread use of coffee and related products may be responsible for false-negative findings in dipyridamole-201Tl cardiac imaging.« less

  9. T1 and T2 mapping for evaluation of myocardial involvement in patients with ANCA-associated vasculitides.

    PubMed

    Greulich, Simon; Mayr, Agnes; Kitterer, Daniel; Latus, Joerg; Henes, Joerg; Steubing, Hannah; Kaesemann, Philipp; Patrascu, Alexandru; Greiser, Andreas; Groeninger, Stefan; Braun, Niko; Alscher, M Dominik; Sechtem, Udo; Mahrholdt, Heiko

    2017-01-06

    Myocardial involvement in AAV patients might be silent, presenting with no or nonspecific symptoms, normal ECG, and preserved left-ventricular ejection fraction (LV-EF). Since up to 50% of deaths in these patients may be due to myocardial involvement, a reliable diagnostic tool is warranted. In contrast to LGE-CMR, which has its strengths in detecting focal inflammatory or fibrotic processes, recent mapping techniques are able to detect even subtle, diffuse inflammatory or fibrotic processes. Our study sought to investigate ANCA (antineutrophil cytoplasmic antibody) associated vasculitides (AAV) patients for myocardial involvement by a cardiovascular magnetic resonance (CMR) protocol, including late gadolinium enhancement (LGE) and mapping sequences. Thirty seven AAV patients were prospectively enrolled and underwent CMR imaging. Twenty healthy volunteers served as controls. Mean LV-EF was 64%; LGE prevalence of the AAV patients was 43%. AAV patients had higher median native T1 (988 vs. 952 ms, p < 0.001), lower post-contrast T1 (488 vs. 524 ms, p = 0.03), expanded extracellular volume (ECV) (27.5 vs. 24.5%, p < 0.001), and higher T2 (53 vs. 49 ms, p < 0.001) compared to controls, with most parameters independent of the LGE status. Native T1 and T2 in AAV patients showed the highest prevalence of abnormally increased values beyond the 95% percentile of controls. AAV patients demonstrated increased T1, ECV, and T2 values, with native T1 and T2 showing the highest prevalence of values beyond the 95% percentile of normal. Since these findings seem to be independent of LGE, mapping techniques may provide complementary information to LGE-CMR in the assessment of myocardial involvement in patients with AAV.

  10. Myocardial perfusion imaging study of CO(2)-induced panic attack.

    PubMed

    Soares-Filho, Gastão L F; Machado, Sergio; Arias-Carrión, Oscar; Santulli, Gaetano; Mesquita, Claudio T; Cosci, Fiammetta; Silva, Adriana C; Nardi, Antonio E

    2014-01-15

    Chest pain is often seen alongside with panic attacks. Moreover, panic disorder has been suggested as a risk factor for cardiovascular disease and even a trigger for acute coronary syndrome. Patients with coronary artery disease may have myocardial ischemia in response to mental stress, in which panic attack is a strong component, by an increase in coronary vasomotor tone or sympathetic hyperactivity setting off an increase in myocardial oxygen consumption. Indeed, coronary artery spasm was presumed to be present in cases of cardiac ischemia linked to panic disorder. These findings correlating panic disorder with coronary artery disease lead us to raise questions about the favorable prognosis of chest pain in panic attack. To investigate whether myocardial ischemia is the genesis of chest pain in panic attacks, we developed a myocardial perfusion study through research by myocardial scintigraphy in patients with panic attacks induced in the laboratory by inhalation of 35% carbon dioxide. In conclusion, from the data obtained, some hypotheses are discussed from the viewpoint of endothelial dysfunction and microvascular disease present in mental stress response. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. An audit of half-count myocardial perfusion imaging using resolution recovery software.

    PubMed

    Lawson, Richard S; White, Duncan; Nijran, Kuldip; Cade, Sarah C; Hall, David O; Kenny, Bob; Knight, Andy; Livieratos, Lefteris; Murray, Anthony; Towey, David

    2014-05-01

    The Nuclear Medicine Software Quality Group of the Institute of Physics and Engineering in Medicine has conducted a multicentre, multivendor audit to evaluate the use of resolution recovery software from several manufacturers when applied to myocardial perfusion data with half the normal counts acquired under a variety of clinical protocols in a range of departments. The objective was to determine whether centres could obtain clinical results with half-count data processed with resolution recovery software that were equivalent to those obtained using their normal protocols. Sixteen centres selected 50 routine myocardial perfusion studies each, from which the Nuclear Medicine Software Quality Group generated simulated half-count studies using Poisson resampling. These half-count studies were reconstructed using resolution recovery and the clinical reports compared with the original reports from the full-count data. A total of 769 patient studies were processed and compared. Eight centres found only a small number of clinically relevant discrepancies between the two reports, whereas eight had an unacceptably high number of discrepancies. There were no significant differences in acquisition parameters between the two groups, although centres finding a high number of discrepancies were more likely to perform both rest and stress scans on normal studies. Half of the participating centres could potentially make use of resolution recovery to reduce the administered activity for myocardial perfusion scans without changing their routine acquisition protocols. The other half could consider adjusting the reconstruction parameters used with their resolution recovery software if they wish to use reduced activity successfully.

  12. Effect of spinal cord stimulation on myocardial perfusion reserve in patients with refractory angina pectoris.

    PubMed

    Saraste, Antti; Ukkonen, Heikki; Varis, Antti; Vasankari, Tuija; Tunturi, Satu; Taittonen, Markku; Rautakorpi, Pirkka; Luotolahti, Matti; Airaksinen, K E Juhani; Knuuti, Juhani

    2015-04-01

    Epidural spinal cord stimulation (SCS) provides symptom relief in refractory angina pectoris, but its mechanism of action remains incompletely understood. We studied effects of short-term SCS therapy on myocardial ischaemia tolerance, myocardial perfusion reserve (MPR), and endothelium-mediated vasodilatation induced by cold pressor test (CPT) in patients with refractory angina pectoris. We prospectively recruited 18 patients with refractory angina pectoris and studied them after implantation of SCS device at baseline before starting the therapy and after 3 weeks of continuous SCS therapy. Myocardial ischaemia was evaluated by dobutamine stress echocardiography. Global and regional myocardial blood flow (MBF) were measured using positron emission tomography and (15)O-water at rest, during adenosine stress, and in response to CPT. Systemic haemodynamics were comparable before and after 3 weeks of SCS at rest, during adenosine stress and during CPT. Appearance of angina pectoris induced by dobutamine stress was delayed after SCS therapy. Global MPR increased (P = 0.02) from 1.7 ± 0.6 at baseline to 2.0 ± 0.6 after 3-week SCS therapy. This was associated with a significant reduction in global MBF at rest and increase in MBF induced by adenosine in the ischaemic regions. Global MBF response to CPT was improved after SCS (0.27 ± 0.20 vs. 0.40 ± 0.15, P = 0.03). Short-term SCS therapy improved myocardial ischaemia tolerance, absolute MPR, and endothelium-mediated vasomotor function in refractory angina pectoris, indicating that this therapy can alleviate myocardial perfusion abnormalities in advanced CAD. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  13. Normalization of reverse redistribution of thallium-201 with procainamide pretreatment in Wolff-Parkinson-White syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nii, T.; Nakashima, Y.; Nomoto, J.

    1991-03-01

    Stress thallium-201 myocardial perfusion imaging was performed in a patient with Wolff-Parkinson-White syndrome. Reverse redistribution phenomenon was observed in the absence of coronary artery disease. This seems to be the first report of normalization of this phenomenon in association with reversion of accessory pathway to normal atrioventricular conduction after pretreatment with procainamide.

  14. First-pass myocardial perfusion MRI with reduced subendocardial dark-rim artifact using optimized Cartesian sampling.

    PubMed

    Zhou, Zhengwei; Bi, Xiaoming; Wei, Janet; Yang, Hsin-Jung; Dharmakumar, Rohan; Arsanjani, Reza; Bairey Merz, C Noel; Li, Debiao; Sharif, Behzad

    2017-02-01

    The presence of subendocardial dark-rim artifact (DRA) remains an ongoing challenge in first-pass perfusion (FPP) cardiac magnetic resonance imaging (MRI). We propose a free-breathing FPP imaging scheme with Cartesian sampling that is optimized to minimize the DRA and readily enables near-instantaneous image reconstruction. The proposed FPP method suppresses Gibbs ringing effects-a major underlying factor for the DRA-by "shaping" the underlying point spread function through a two-step process: 1) an undersampled Cartesian sampling scheme that widens the k-space coverage compared to the conventional scheme; and 2) a modified parallel-imaging scheme that incorporates optimized apodization (k-space data filtering) to suppress Gibbs-ringing effects. Healthy volunteer studies (n = 10) were performed to compare the proposed method against the conventional Cartesian technique-both using a saturation-recovery gradient-echo sequence at 3T. Furthermore, FPP imaging studies using the proposed method were performed in infarcted canines (n = 3), and in two symptomatic patients with suspected coronary microvascular dysfunction for assessment of myocardial hypoperfusion. Width of the DRA and the number of DRA-affected myocardial segments were significantly reduced in the proposed method compared to the conventional approach (width: 1.3 vs. 2.9 mm, P < 0.001; number of segments: 2.6 vs. 8.7; P < 0.0001). The number of slices with severe DRA was markedly lower for the proposed method (by 10-fold). The reader-assigned image quality scores were similar (P = 0.2), although the quantified myocardial signal-to-noise ratio was lower for the proposed method (P < 0.05). Animal studies showed that the proposed method can detect subendocardial perfusion defects and patient results were consistent with the gold-standard invasive test. The proposed free-breathing Cartesian FPP imaging method significantly reduces the prevalence of severe DRAs compared to the conventional approach

  15. Stress Cardiac MRI in Women With Myocardial Infarction and Nonobstructive Coronary Artery Disease.

    PubMed

    Mauricio, Rina; Srichai, Monvadi B; Axel, Leon; Hochman, Judith S; Reynolds, Harmony R

    2016-10-01

    In a prospective study, cardiac MRI (CMR) and intravascular ultrasound were performed in women with myocardial infarction (MI) and nonobstructive coronary artery disease (MINOCA). Forty participants underwent adenosine-stress CMR (sCMR). Abnormal perfusion may co-localize with ischemic late gadolinium enhancement (LGE) and T2-weighted signal hyperintensity (T2+), suggesting microvascular dysfunction contributed to MI. Qualitative perfusion analysis was performed by 2 independent readers. Abnormal myocardial perfusion reserve index (MPRI) was defined as global average ≤1.84. Abnormal rest perfusion was present in 10 patients (25%) and stress perfusion abnormalities in 25 (63%). Abnormal stress perfusion was not associated with LGE but tended to occur with T2+. Among patients with abnormal perfusion and LGE, the LGE pattern was ischemic in half. The locations of abnormal perfusion and LGE matched in 75%, T2+ in 100%. Abnormal stress perfusion was not associated with plaque disruption and matched in location in 63%. MPRI was abnormal in 10 patients (25%) and was not associated with LGE, T2+ or plaque disruption. Abnormal perfusion on sCMR is common among women with MINOCA. Abnormal perfusion usually co-localized with LGE and/or T2+ when present. Variability in LGE pattern leads to uncertainty about whether the finding of abnormal perfusion was cause or consequence of the tissue state leading to LGE. Low MPRI, possibly indicating diffuse microvascular disease, was observed with and without LGE and T2+. Multiple mechanisms may lead to abnormal perfusion on sCMR. Microvascular dysfunction may contribute to the pathogenesis of and coexist with other causes of MINOCA. © 2016 Wiley Periodicals, Inc.

  16. Assessment of cardiac function using myocardial perfusion imaging technique on SPECT with 99mTc sestamibi

    NASA Astrophysics Data System (ADS)

    Gani, M. R. A.; Nazir, F.; Pawiro, S. A.; Soejoko, D. S.

    2016-03-01

    Suspicion on coronary heart disease can be confirmed by observing the function of left ventricle cardiac muscle with Myocardial Perfusion Imaging techniques. The function perfusion itself is indicated by the uptake of radiopharmaceutical tracer. The 31 patients were studied undergoing the MPI examination on Gatot Soebroto Hospital using 99mTc-sestamibi radiopharmaceutical with stress and rest conditions. Stress was stimulated by physical exercise or pharmacological agent. After two hours, the patient did rest condition on the same day. The difference of uptake percentage between stress and rest conditions will be used to determine the malfunction of perfusion due to ischemic or infarct. Degradation of cardiac function was determined based on the image-based assessment of five segments of left ventricle cardiac. As a result, 8 (25.8%) patients had normal myocardial perfusion and 11 (35.5%) patients suspected for having partial ischemia. Total ischemia occurred to 8 (25.8%) patients with reversible and irreversible ischemia and the remaining 4 (12.9%) patients for partial infarct with characteristic the percentage of perfusion ≤50%. It is concluded that MPI technique of image-based assessment on uptake percentage difference between stress and rest conditions can be employed to predict abnormal perfusion as complementary information to diagnose the cardiac function.

  17. Prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia: study by 99mTc-sestamibi radionuclide scintigraphy.

    PubMed

    Ismail, Ahmed M; Rayan, Mona; Adel, Amr; Demerdash, Salah; Atef, Mohamed; Abdallah, Mohamed; Nammas, Wail

    2014-02-01

    We explored the prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia (CAE), as demonstrated by (99m)Tc-sestamibi scintigraphy. Prospectively, we enrolled 35 patients with angiographically documented CAE and no significant coronary obstruction, who underwent elective coronary angiography. Patients underwent Stress-rest (99m)Tc-sestamibi scintigraphy within 4 days of coronary angiography. They were divided into 2 groups: group I: with normal perfusion scan; and group II: with reversible perfusion defects. The mean age was 49.6 ± 6.9 years; 34 (97.1 %) were males. Seventy-nine (75.2 %) arteries were affected by CAE. Among 79 arteries affected by CAE, affection was diffuse in 37 (46.8 %). Thirteen (37.1 %) patients had normal perfusion scan (group I), whereas 22 (62.9 %) had reversible perfusion defects (group II). Among 22 patients with reversible perfusion defects, 20 (90.9 %) had mild and 2 (9.1 %) had moderate ischemia. Among 49 myocardial segments with reversible perfusion defects, 22 (44.9 %) were basal, 18 (36.7 %) mid-, and 9 (18.4 %) apical segments. Diffuse CAE was significantly more prevalent in group II versus group I, in all 3 major coronary arteries (p < 0.05 for all). In patients with isolated CAE who underwent elective coronary angiography, reversible perfusion defects demonstrated by (99m)Tc-sestamibi scintigraphy were rather prevalent, mostly mild, more likely to affect the basal and mid-segments of the myocardium, and more frequently associated with diffuse ectasia.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kahan, A.; Devaux, J.Y.; Amor, B.

    In systemic sclerosis, abnormalities of myocardial perfusion are common and may be caused by a disturbance of the coronary microcirculation. We evaluated the long-term effect of captopril (75 to 150 mg per day) on thallium 201 myocardial perfusion in 12 normotensive patients with systemic sclerosis. Captopril significantly decreased the mean (+/- SD) number of segments with thallium 201 myocardial perfusion defects (6.5 +/- 1.9 at baseline and 4.4 +/- 2.7 after 1 year of treatment with captopril; p less than 0.02) and increased the mean global thallium score (9.6 +/- 1.7 at baseline and 11.4 +/- 2.1 after captopril; pmore » less than 0.05). In a control group of eight normotensive patients with systemic sclerosis who did not receive captopril, no significant modification in thallium results occurred. Side effects with captopril included hypotension (six patients), taste disturbances (one patient), and skin rash (one patient). These side effects subsided when the dosage was reduced. These findings demonstrate that captopril improves thallium 201 myocardial perfusion in patients with systemic sclerosis and may therefore have a beneficial effect on scleroderma myocardial disease.« less

  19. Present assessment of myocardial viability by nuclear imaging.

    PubMed

    Saha, G B; MacIntyre, W J; Brunken, R C; Go, R T; Raja, S; Wong, C O; Chen, E Q

    1996-10-01

    Prospective delineation of viable from nonviable myocardium in patients with coronary artery disease in an important factor in deciding whether a patient should be revascularized or treated medically. Two common techniques--single-photon emission computed tomography (SPECT) and positron-emission computed tomography (PET)--are used in nuclear medicine using various radiopharmaceuticals for the detection of myocardial viability in patients. Thallium-201 (201Tl) and technetium-99m (99mTc)-sestamibi are the common radiopharmaceuticals used in different protocols using SPECT, whereas fluoride-18 (18F)-fluorodeoxyglucose (FDG) and rubidium-82 (82Rb) are most widely used in PET. The SPECT protocols involve stress/redistribution, stress/redistribution/reinjection, and rest/redistribution imaging techniques. Many studies have compared the results of 201Tl and (99mTc)-sestamibi SPECT with those of FDG PET; in some studies, concordant results have been found between delayed thallium and FDG results, indicating that 201Tl, although considered a perfusion agent, shows myocardial viability. Discordant results in a number of studies have been found between sestamibi and FDG, suggesting that the efficacy of sestamibi as a viability marker has yet to be established. Radiolabeled fatty acids such as iodine-123 (123I)-para-iodophenylpentadecanoic acid and carbon-11 (11C)-palmitic acid have been used for the assessment of myocardial viability with limited success. 11C-labeled acetate is a good marker of oxidative metabolism in the heart and has been used to predict the reversibility of wall motion abnormalities. (18F)-FDG is considered the marker of choice for myocardial viability, although variable results are obtained under different physiological conditions. Detection of myocardial viability can be greatly improved by developing new equipment and radiopharmaceuticals of better quality.

  20. Pilot study testing the effect of physical training over the myocardial perfusion and quality of life in patients with primary microvascular angina.

    PubMed

    de Carvalho, Eduardo Elias Vieira; Santi, Giovani Luiz; Crescêncio, Júlio César; de Oliveira, Luciano Fonseca Lemos; dos Reis, Daniela Caetano Costa; Figueiredo, Alexandre Baldini; Pintya, Antonio Osvaldo; Lima-Filho, Moyses Oliveira; Gallo-Júnior, Lourenço; Marin-Neto, José Antonio; Simões, Marcus Vinícius

    2015-02-01

    Primary microvascular angina (PMA) is a common clinical condition associated to negative impact on quality of life (QOL) and reduced physical capacity. This study aimed at evaluating the effects of aerobic physical training (APT) on myocardial perfusion, physical capacity, and QOL in patients with PMA. We investigated 12 patients (53.8 ± 9.7 years old; 7 women) with PMA, characterized by angina, angiographycally normal coronary arteries, and reversible perfusion defects (RPDs) detected on (99m)Tc-sestamibi-SPECT myocardial perfusion scintigraphy (MPS). At baseline and after 4 month of APT, the patients underwent MPS, cardiopulmonary test, and QOL questionnaire. Stress-rest MPS images were visually analyzed by attributing semi-quantitative scores (0 = normal; 4 = absent uptake), using a 17-segment left ventricular model. Summed stress, rest, and difference scores (SDS) were calculated. In comparison to the baseline, in the post-training we observed a significant increase in peak-VO2 (19.4 ± 4.8 and 22.1 ± 6.2 mL·kg(-1)·minute(-1), respectively, P = .01), reduction of SDS (10.1 ± 8.8 and 2.8 ± 4.9, P = .008), and improvement in QOL scores. Physical training in patients with PMA is associated with reduction of myocardial perfusion abnormalities, increasing of physical capacity, and improvement in QOL. The findings of this hypothesis-generating study suggest that APT can be a valid therapeutic option for patients with PMA.

  1. High-frequency Electrocardiogram Analysis in the Ability to Predict Reversible Perfusion Defects during Adenosine Myocardial Perfusion Imaging

    NASA Technical Reports Server (NTRS)

    Tragardh, Elin; Schlegel, Todd T.; Carlsson, Marcus; Pettersson, Jonas; Nilsson, Klas; Pahlm, Olle

    2007-01-01

    Background: A previous study has shown that analysis of high-frequency QRS components (HF-QRS) is highly sensitive and reasonably specific for detecting reversible perfusion defects on myocardial perfusion imaging (MPI) scans during adenosine. The purpose of the present study was to try to reproduce those findings. Methods: 12-lead high-resolution electrocardiogram recordings were obtained from 100 patients before (baseline) and during adenosine Tc-99m-tetrofosmin MPI tests. HF-QRS were analyzed regarding morphology and changes in root mean square (RMS) voltages from before the adenosine infusion to peak infusion. Results: The best area under the curve (AUC) was found in supine patients (AUC=0.736) in a combination of morphology and RMS changes. None of the measurements, however, were statistically better than tossing a coin (AUC=0.5). Conclusion: Analysis of HF-QRS was not significantly better than tossing a coin for determining reversible perfusion defects on MPI scans.

  2. Resveratrol Improves Myocardial Perfusion in a Swine Model of Hypercholesterolemia and Chronic Myocardial Ischemia

    PubMed Central

    Robich, Michael P.; Osipov, Robert M.; Nezafat, Reza; Feng, Jun; Clements, Richard T.; Bianchi, Cesario; Boodhwani, Munir; Coady, Michael A.; Laham, Roger J.; Sellke, Frank W.

    2010-01-01

    Introduction Resveratrol may provide protection against coronary artery disease. We hypothesized that supplemental resveratrol will improve cardiac perfusion in the ischemic territory of swine with hypercholesterolemia and chronic myocardial ischemia. Methods and Results Yorkshire swine were fed either a normal diet (control, n=7), a hypercholesterolemic diet (HCC, n=7), or a hypercholesterolemic diet with supplemental resveratrol (100 mg/kg/day orally, HCRV, n=7). Four weeks later, an ameroid constrictor was placed on the left circumflex artery. Animals underwent cardiac magnetic resonance imaging and coronary angiography 7 weeks later, prior to sacrifice and tissue harvest. Total cholesterol was lowered about 30% in HCRV animals (p<0.001). Regional wall motion analysis demonstrated a significant decrease in inferolateral function from baseline to 7 weeks in HCC swine (p=0.04). There was no significant change in regional function in HCRV swine from baseline to 7 weeks (p=0.32). Tissue blood flow during stress was 2.8 fold greater in HCRV swine when compared to HCC swine (p=0.04). Endothelial dependent microvascular relaxation response to Substance P was diminished in HCC swine which was rescued by resveratrol treatment (p=0.004). Capillary density (PECAM-1 staining) demonstrated fewer capillaries in both HCC and HCRV swine v. control swine (p=0.02). Immunoblot analysis demonstrated significantly greater expression in HCRV v. HCC swine of the following markers of angiogenesis: VEGF (p=0.002), peNOS(ser1177)(p=0.04), NFkB (p=0.004), and pAkt(thr308)(p=0.001). Conclusion Supplemental resveratrol attenuates regional wall motion abnormalities, improves myocardial perfusion in the collateral dependent region, preserves endothelial dependent coronary vessel function, and upregulates markers of angiogenesis associated with the VEGF signaling pathway. PMID:20837905

  3. The dream of a one-stop-shop: Meta-analysis on myocardial perfusion CT.

    PubMed

    Pelgrim, Gert Jan; Dorrius, Monique; Xie, Xueqian; den Dekker, Martijn A M; Schoepf, U Joseph; Henzler, Thomas; Oudkerk, Matthijs; Vliegenthart, Rozemarijn

    2015-12-01

    To determine the diagnostic performance of computed tomography (CT) perfusion techniques for the detection of functionally relevant coronary artery disease (CAD) in comparison to reference standards, including invasive coronary angiography (ICA), single photon emission computed tomography (SPECT), and magnetic resonance imaging (MRI). PubMed, Web of Knowledge and Embase were searched from January 1, 1998 until July 1, 2014. The search yielded 9475 articles. After duplicate removal, 6041 were screened on title and abstract. The resulting 276 articles were independently analyzed in full-text by two reviewers, and included if the inclusion criteria were met. The articles reporting diagnostic parameters including true positive, true negative, false positive and false negative were subsequently evaluated for the meta-analysis. Results were pooled according to CT perfusion technique, namely snapshot techniques: single-phase rest, single-phase stress, single-phase dual-energy stress and combined coronary CT angiography [rest] and single-phase stress, as well the dynamic technique: dynamic stress CT perfusion. Twenty-two articles were included in the meta-analysis (1507 subjects). Pooled per-patient sensitivity and specificity of single-phase rest CT compared to rest SPECT were 89% (95% confidence interval [CI], 82-94%) and 88% (95% CI, 78-94%), respectively. Vessel-based sensitivity and specificity of single-phase stress CT compared to ICA-based >70% stenosis were 82% (95% CI, 64-92%) and 78% (95% CI, 61-89%). Segment-based sensitivity and specificity of single-phase dual-energy stress CT in comparison to stress MRI were 75% (95% CI, 60-85%) and 95% (95% CI, 80-99%). Segment-based sensitivity and specificity of dynamic stress CT perfusion compared to stress SPECT were 77% (95% CI, 67-85) and 89% (95% CI, 78-95%). For combined coronary CT angiography and single-phase stress CT, vessel-based sensitivity and specificity in comparison to ICA-based >50% stenosis were 84% (95

  4. Navigator-gated 3D blood oxygen level-dependent CMR at 3.0-T for detection of stress-induced myocardial ischemic reactions.

    PubMed

    Jahnke, Cosima; Gebker, Rolf; Manka, Robert; Schnackenburg, Bernhard; Fleck, Eckart; Paetsch, Ingo

    2010-04-01

    This study determined the value of navigator-gated 3-dimensional blood oxygen level-dependent (BOLD) cardiac magnetic resonance (CMR) at 3.0-T for the detection of stress-induced myocardial ischemic reactions. Although BOLD CMR has been introduced for characterization of myocardial oxygenation status, previously reported CMR approaches suffered from a low signal-to-noise ratio and motion-related artifacts with impaired image quality and a limited diagnostic value in initial patient studies. Fifty patients with suspected or known coronary artery disease underwent CMR at 3.0-T followed by invasive X-ray angiography within 48 h. Three-dimensional BOLD images were acquired during free breathing with full coverage of the left ventricle in a short-axis orientation. The BOLD imaging was performed at rest and under adenosine stress, followed by stress and rest first-pass perfusion and delayed enhancement imaging. Quantitative coronary X-ray angiography (QCA) was used for coronary stenosis definition (diameter reduction > or =50%). The BOLD and first-pass perfusion images were semiquantitatively evaluated (for BOLD imaging, signal intensity differences between stress and rest [DeltaSI]; for perfusion imaging, myocardial perfusion reserve index [MPRI]). The image quality of BOLD CMR at rest and during adenosine stress was considered good to excellent in 90% and 84% of the patients, respectively. The DeltaSI measurements differed significantly between normal myocardium, myocardium supplied by a stenotic coronary artery, and infarcted myocardium (p < 0.001). The receiver-operator characteristic analysis identified a cutoff value of DeltaSI = 2.7% for the detection of coronary stenosis, resulting in a sensitivity and specificity of 85.0% and 80.5%, respectively. An MPRI cutoff value of 1.35 yielded a sensitivity and specificity of 89.5% and 85.8%, respectively. The DeltaSI significantly correlated with the degree of coronary stenosis (r = -0.65, p < 0.001). Additionally, Delta

  5. MR fingerprinting for rapid quantification of myocardial T1 , T2 , and proton spin density.

    PubMed

    Hamilton, Jesse I; Jiang, Yun; Chen, Yong; Ma, Dan; Lo, Wei-Ching; Griswold, Mark; Seiberlich, Nicole

    2017-04-01

    To introduce a two-dimensional MR fingerprinting (MRF) technique for quantification of T 1 , T 2 , and M 0 in myocardium. An electrocardiograph-triggered MRF method is introduced for mapping myocardial T 1 , T 2 , and M 0 during a single breath-hold in as short as four heartbeats. The pulse sequence uses variable flip angles, repetition times, inversion recovery times, and T 2 preparation dephasing times. A dictionary of possible signal evolutions is simulated for each scan that incorporates the subject's unique variations in heart rate. Aspects of the sequence design were explored in simulations, and the accuracy and precision of cardiac MRF were assessed in a phantom study. In vivo imaging was performed at 3 Tesla in 11 volunteers to generate native parametric maps. T 1 and T 2 measurements from the proposed cardiac MRF sequence correlated well with standard spin echo measurements in the phantom study (R 2  > 0.99). A Bland-Altman analysis revealed good agreement for myocardial T 1 measurements between MRF and MOLLI (bias 1 ms, 95% limits of agreement -72 to 72 ms) and T 2 measurements between MRF and T 2 -prepared balanced steady-state free precession (bias, -2.6 ms; 95% limits of agreement, -8.5 to 3.3 ms). MRF can provide quantitative single slice T 1 , T 2 , and M 0 maps in the heart within a single breath-hold. Magn Reson Med 77:1446-1458, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. [Clinical significance of myocardial 123I-BMIPP imaging in patients with myocardial infarction].

    PubMed

    Narita, M; Kurihara, T; Shindoh, T; Honda, M

    1997-03-01

    In order to clarify the characteristics of fatty acid metabolism in patients with myocardial infarction (MI), we performed myocardial imaging with 123I-beta-methyl-p-iodophenylpentadecanoic acid (BMIPP) and we compared these findings with exercise stress (Ex) and resting myocardial perfusion imaging with 99mTc-methoxyisobutylisonitrile (MIBI) and left ventricular wall motion index (WMI) which were obtained by left ventriculography. We studied 55 patients with MI, 14 patients with recent MI (RMI) and 41 patients with old MI (OMI), and myocardial images were divided into 17 segments and myocardial uptake of the radionuclide was graded from 0 (normal) to 3 (maximal abnormality). In 28 patients we compared segmental defect score (SDS) with WMI which were obtained by centerline method at the corresponded segments. As a whole, the mean total defect scores (TDSs) of BMIPP and Ex were similar and they were greater than the mean TDS of resting perfusion. In 30 patient (55%) TDS of BMIPP was greater than that of TDS of resting perfusion. In 24 patients perfusion abnormality developed by Ex and the location of BMIPP abnormality coincided with the abnormality of Ex. But in the other 6 patients Ex did not induce any abnormality and they were all RMI and infarcted coronary artery was patent. However in the group with TDS of BMIPP identical to TDS of resting perfusion (25 patients), 92% did not show myocardial perfusion abnormality after Ex. In the comparison of SDS and WMI, myocardial segments were divided into 3 groups; both SDSs of BMIPP and resting perfusion were normal or borderline abnormality (Group 1, 82 segments), SDS of resting perfusion was normal or borderline and SDS of BMIPP was definitely abnormal (Group 2, 10 segments) and both SDSs of BMIPP and resting perfusion were definitely abnormal (Group 3, 48 segments). In Group 1, WMS (-0.41 +/- 0.77) was significantly (p < 0.001) greater than those of Group 2 (-2.14 +/- 0.50) and Group 3 (-2.32 +/- 0.67). But there was

  7. Comparison of 18F-Labeled Fluoroalkylphosphonium Cations with 13N-NH3 for PET Myocardial Perfusion Imaging.

    PubMed

    Kim, Dong-Yeon; Kim, Hyeon Sik; Reder, Sybille; Zheng, Jin Hai; Herz, Michael; Higuchi, Takahiro; Pyo, A Young; Bom, Hee-Seung; Schwaiger, Markus; Min, Jung-Joon

    2015-10-01

    Despite substantial advances in the diagnosis of cardiovascular disease, there is a need for 18F-labeled myocardial perfusion agents for the diagnosis of ischemic heart disease because current PET tracers for myocardial perfusion imaging have a short half-life that limits their widespread clinical use in PET. Thus, 18F-labeled fluoroalkylphosphonium derivatives (18F-FATPs), including (5-18F-fluoropentyl)triphenylphosphonium cation (18F-FPTP), (6-18F-fluorohexyl)triphenylphosphonium cation (18F-FHTP), and (2-(2-18F-fluoroethoxy)ethyl)triphenylphosphonium cation (18F-FETP), were synthesized. The myocardial extraction and image quality of the 18F-FATPs were compared with those of 13N-NH3 in rat models. The first-pass extraction fraction (EF) values of the 18F-FATPs (18F-FPTP, 18F-FHTP, 18F-FETP) and 13N-NH3 were measured in isolated rat hearts perfused with the Langendorff method (flow velocities, 0.5, 4.0, 8.0, and 16.0 mL/min). Normal and myocardial infarction rats were imaged with small-animal PET after intravenous injection of 37 MBq of 18F-FATPs and 13N-NH3. To determine pharmacokinetics, a region of interest was drawn around the heart, and time-activity curves of the 18F-FATPs and 13N-NH3 were generated to obtain the counts per pixel per second. Defect size was analyzed on the basis of polar map images of 18F-FATPs and 13N-NH3. The EF values of 18F-FATPs and 13N-NH3 were comparable at low flow velocity (0.5 mL/min), whereas at higher flows EF values of 18F-FATPs were significantly higher than those of 13N-NH3 (4.0, 8.0, and 16.0 mL/min, P<0.05). Myocardium-to-liver ratios of 18F-FPTP, 18F-FHTP, 18F-FETP, and 13N-NH3 were 2.10±0.30, 4.36±0.20, 3.88±1.03, and 0.70±0.09, respectively, 10 min after injection, whereas myocardium-to-lung ratios were 5.00±0.25, 4.33±0.20, 7.98±1.23, and 2.26±0.14, respectively. Although 18F-FATPs and 13N-NH3 sharply delineated myocardial perfusion defects, defect size on the 13N-NH3 images was significantly smaller than on the

  8. Myocardial uptake of cocaine and effects of cocaine on myocardial substrate utilization and perfusion in hypertensive rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Som, P.; Wang, G.J.; Oster, Z.H.

    Cocaine abuse is a problem causing world-wide concern and the number of deaths following cocaine use is increasing. Cardiovascular complications following cocaine include severe tachyarrythmias, pulmonary edema, myocardial infarction, and acute renal failure, which are major problems confronting emergency facilities. While the studies of cocaine effects on the brain have been given the most attention, it is clear that the effects of cocaine on the cardiovascular system are of great importance, given the increasing number of reports on sudden death and myocardial infarctions in young adults related to cocaine use. The precise mechanisms of cardiotoxic actions of cocaine are unclear.more » We investigated the whole-body distribution of C-14-labeled cocaine to determine the cocaine-binding sites, including blocking experiments to determine the nature of regional binding sites, and differential response of the normal vs. diseased heart (hypertensive cardiomyopathy) in an animal model to mimic a potentially high risk population. We investigated the acute effects of cocaine on myocardial metabolism using two myocardial energy substrate analogs, fatty acid and glucose with comparison with regional perfusion.« less

  9. Dipyridamole stress myocardial perfusion by computed tomography in patients with left bundle branch block.

    PubMed

    Cabeda, Estêvan Vieira; Falcão, Andréa Maria Gomes; Soares, José; Rochitte, Carlos Eduardo; Nomura, César Higa; Ávila, Luiz Francisco Rodrigues; Parga, José Rodrigues

    2015-12-01

    Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution's ethics committee. The patients' mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.

  10. Temporal Trends in the Prevalence, Severity, and Localization of Myocardial Ischemia and Necrosis at Myocardial Perfusion Imaging After Myocardial Infarction.

    PubMed

    Nudi, Francesco; Schillaci, Orazio; Di Belardino, Natale; Versaci, Francesco; Tomai, Fabrizio; Pinto, Annamaria; Neri, Giandomenico; Procaccini, Enrica; Nudi, Alessandro; Frati, Giacomo; Biondi-Zoccai, Giuseppe

    2017-10-15

    The definition, presentation, and management of myocardial infarction (MI) have changed substantially in the last decade. Whether these changes have impacted on the presence, severity, and localization of necrosis at myocardial perfusion imaging (MPI) has not been appraised to date. Subjects undergoing MPI and reporting a history of clinical MI were shortlisted. We focused on the presence, severity, and localization of necrosis at MPI with a retrospective single-center analysis. A total of 10,476 patients were included, distinguishing 5 groups according to the period in which myocardial perfusion scintigraphy had been performed (2004 to 2005, 2006 to 2007, 2008 to 2009, 2010 to 2011, 2012 to 2013). Trend analysis showed over time a significant worsening in baseline features (e.g., age, diabetes mellitus, and Q waves at electrocardiogram), whereas medical therapy and revascularization were offered with increasing frequency. Over the years, there was also a lower prevalence of normal MPI (from 16.8% to 13.6%) and ischemic MPI (from 35.6% to 32.8%), and a higher prevalence of ischemic and necrotic MPI (from 12.0% to 12.7%) or solely necrotic MPI (from 35.7% to 40.9%, p <0.001). Yet the prevalence of severe ischemia decreased over time from 11.4% to 2.0%, with a similar trend for moderate ischemia (from 15.9% to 11.8%, p <0.001). Similarly sobering results were wound for the prevalence of severe necrosis (from 19.8% to 8.2%) and moderate necrosis (from 8.5% to 7.8%, p = 0.028). These trends were largely confirmed at regional level and after propensity score matching. In conclusion, the outlook of stable patients with previous MI has substantially improved in the last decade, with a decrease in the severity of residual myocardial ischemia and necrosis, despite an apparent worsening in baseline features. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Robust dynamic myocardial perfusion CT deconvolution using adaptive-weighted tensor total variation regularization

    NASA Astrophysics Data System (ADS)

    Gong, Changfei; Zeng, Dong; Bian, Zhaoying; Huang, Jing; Zhang, Xinyu; Zhang, Hua; Lu, Lijun; Feng, Qianjin; Liang, Zhengrong; Ma, Jianhua

    2016-03-01

    Dynamic myocardial perfusion computed tomography (MPCT) is a promising technique for diagnosis and risk stratification of coronary artery disease by assessing the myocardial perfusion hemodynamic maps (MPHM). Meanwhile, the repeated scanning of the same region results in a relatively large radiation dose to patients potentially. In this work, we present a robust MPCT deconvolution algorithm with adaptive-weighted tensor total variation regularization to estimate residue function accurately under the low-dose context, which is termed `MPD-AwTTV'. More specifically, the AwTTV regularization takes into account the anisotropic edge property of the MPCT images compared with the conventional total variation (TV) regularization, which can mitigate the drawbacks of TV regularization. Subsequently, an effective iterative algorithm was adopted to minimize the associative objective function. Experimental results on a modified XCAT phantom demonstrated that the present MPD-AwTTV algorithm outperforms and is superior to other existing deconvolution algorithms in terms of noise-induced artifacts suppression, edge details preservation and accurate MPHM estimation.

  12. Simultaneous Assessment of Myocardial Perfusion, Wall Motion, and Deformation during Myocardial Contrast Echocardiography: A Feasibility Study.

    PubMed

    Zoppellaro, Giacomo; Venneri, Lucia; Khattar, Rajdeep S; Li, Wei; Senior, Roxy

    2016-06-01

    Ultrasound contrast agents may be used for the assessment of regional wall motion and myocardial perfusion, but are generally considered not suitable for deformation analysis. The aim of our study was to assess the feasibility of deformation imaging on contrast-enhanced images using a novel methodology. We prospectively enrolled 40 patients who underwent stress echocardiography with continuous intravenous infusion of SonoVue for the assessment of myocardial perfusion imaging with flash replenishment technique. We compared longitudinal strain (Lε) values, assessed with a vendor-independent software (2D CPA), on 68 resting contrast-enhanced and 68 resting noncontrast recordings. Strain analysis on contrast recordings was evaluated in the first cardiac cycles after the flash. Tracking of contrast images was deemed feasible in all subjects and in all views. Contrast administration improved image quality and increased the number of segments used for deformation analysis. Lε of noncontrast and contrast-enhanced images were statistically different (-18.8 ± 4.5% and -22.8 ± 5.4%, respectively; P < 0.001), but their correlation was good (ICC 0.65, 95%CI 0.42-0.78). Patients with resting wall-motion abnormalities showed lower Lε values on contrast recordings (-18.6 ± 6.0% vs. -24.2 ± 5.5%, respectively; P < 0.01). Intra-operator and inter-operator reproducibility was good for both noncontrast and contrast images with no statistical differences. Our study shows that deformation analysis on postflash contrast-enhanced images is feasible and reproducible. Therefore, it would be possible to perform a simultaneous evaluation of wall-motion abnormalities, volumes, ejection fraction, perfusion defects, and cardiac deformation on the same contrast recording. © 2016, Wiley Periodicals, Inc.

  13. The effect of time-of-flight and point spread function modeling on 82Rb myocardial perfusion imaging of obese patients.

    PubMed

    Dasari, Paul K R; Jones, Judson P; Casey, Michael E; Liang, Yuanyuan; Dilsizian, Vasken; Smith, Mark F

    2018-06-15

    The effect of time-of-flight (TOF) and point spread function (PSF) modeling in image reconstruction has not been well studied for cardiac PET. This study assesses their separate and combined influence on 82 Rb myocardial perfusion imaging in obese patients. Thirty-six obese patients underwent rest-stress 82 Rb cardiac PET. Images were reconstructed with and without TOF and PSF modeling. Perfusion was quantitatively compared using the AHA 17-segment model for patients grouped by BMI, cross-sectional body area in the scanner field of view, gender, and left ventricular myocardial volume. Summed rest scores (SRS), summed stress scores (SSS), and summed difference scores (SDS) were compared. TOF improved polar map visual uniformity and increased septal wall perfusion by up to 10%. This increase was greater for larger patients, more evident for patients grouped by cross-sectional area than by BMI, and more prominent for females. PSF modeling increased perfusion by about 1.5% in all cardiac segments. TOF modeling generally decreased SRS and SSS with significant decreases between 2.4 and 3.0 (P < .05), which could affect risk stratification; SDS remained about the same. With PSF modeling, SRS, SSS, and SDS were largely unchanged. TOF and PSF modeling affect regional and global perfusion, SRS, and SSS. Clinicians should consider these effects and gender-dependent differences when interpreting 82 Rb perfusion studies.

  14. A relative quantitative assessment of myocardial perfusion by first-pass technique: animal study

    NASA Astrophysics Data System (ADS)

    Chen, Jun; Zhang, Zhang; Yu, Xuefang; Zhou, Kenneth J.

    2015-03-01

    The purpose of this study is to quantitatively assess the myocardial perfusion by first-pass technique in swine model. Numerous techniques based on the analysis of Computed Tomography (CT) Hounsfield Unit (HU) density have emerged. Although these methods proposed to be able to assess haemodynamically significant coronary artery stenosis, their limitations are noticed. There are still needs to develop some new techniques. Experiments were performed upon five (5) closed-chest swine. Balloon catheters were placed into the coronary artery to simulate different degrees of luminal stenosis. Myocardial Blood Flow (MBF) was measured using color microsphere technique. Fractional Flow Reserve (FFR) was measured using pressure wire. CT examinations were performed twice during First-pass phase under adenosine-stress condition. CT HU Density (HUDCT) and CT HU Density Ratio (HUDRCT) were calculated using the acquired CT images. Our study presents that HUDRCT shows a good (y=0.07245+0.09963x, r2=0.898) correlation with MBF and FFR. In receiver operating characteristic (ROC) curve analyses, HUDRCT provides excellent diagnostic performance for the detection of significant ischemia during adenosine-stress as defined by FFR indicated by the value of Area Under the Curve (AUC) of 0.927. HUDRCT has the potential to be developed as a useful indicator of quantitative assessment of myocardial perfusion.

  15. Blunted Myocardial Oxygenation Response During Vasodilator Stress in Patients With Hypertrophic Cardiomyopathy

    PubMed Central

    Karamitsos, Theodoros D.; Dass, Sairia; Suttie, Joseph; Sever, Emily; Birks, Jacqueline; Holloway, Cameron J.; Robson, Matthew D.; Jerosch-Herold, Michael; Watkins, Hugh; Neubauer, Stefan

    2013-01-01

    Objectives This study sought to assess myocardial perfusion and tissue oxygenation during vasodilator stress in patients with overt hypertrophic cardiomyopathy (HCM), as well as in HCM mutation carriers without left ventricular (LV) hypertrophy, and to compare findings to those in athletes with comparable hypertrophy and normal controls. Background Myocardial perfusion under vasodilator stress is impaired in patients with HCM. Whether this is associated with impaired myocardial oxygenation and tissue ischemia is unknown. Furthermore, it is not known whether perfusion and oxygenation are impaired in HCM mutation carriers without left ventricular hypertrophy (LVH). Methods A total of 27 patients with overt HCM, 10 HCM mutation carriers without LVH, 11 athletes, and 20 healthy controls underwent cardiovascular magnetic resonance (CMR) scanning at 3-T. Myocardial function, perfusion (perfusion reserve index [MPRI]), and oxygenation (blood-oxygen level dependent signal intensity [SI] change) under adenosine stress were assessed. Results MPRI was significantly reduced in HCM (1.3 ± 0.1) compared to controls (1.8 ± 0.1, p < 0.001) and athletes (2.0 ± 0.1, p < 0.001), but remained normal in HCM mutation carriers without LVH (1.7 ± 0.1; p = 0.61 vs. controls, p = 0.02 vs. overt HCM). Oxygenation response was attenuated in overt HCM (SI change 6.9 ± 1.4%) compared to controls (18.9 ± 1.4%, p < 0.0001) and athletes (18.7 ± 2.0%, p < 0.001). Interestingly, HCM mutation carriers without LVH also showed an impaired oxygenation response to adenosine (10.4 ± 2.0%; p = 0.001 vs. controls, p = 0.16 vs. overt HCM, p = 0.003 vs. athletes). Conclusions In overt HCM, both perfusion and oxygenation are impaired during vasodilator stress. However, in HCM mutation carriers without LVH, only oxygenation is impaired. In athletes, stress perfusion and oxygenation are normal. CMR assessment of myocardial oxygenation has the potential to become a novel risk factor in HCM. PMID:23498131

  16. A Comparison of Theory-Based and Experimentally Determined Myocardial Signal Intensity Correction Methods in First-Pass Perfusion Magnetic Resonance Imaging.

    PubMed

    Fluckiger, Jacob U; Benefield, Brandon C; Bakhos, Lara; Harris, Kathleen R; Lee, Daniel C

    2015-01-01

    To evaluate the impact of correcting myocardial signal saturation on the accuracy of absolute myocardial blood flow (MBF) measurements. We performed 15 dual bolus first-pass perfusion studies in 7 dogs during global coronary vasodilation and variable degrees of coronary artery stenosis. We compared microsphere MBF to MBF calculated from uncorrected and corrected MRI signal. Four correction methods were tested, two theoretical methods (Th1 and Th2) and two empirical methods (Em1 and Em2). The correlations with microsphere MBF (n = 90 segments) were: uncorrected (y = 0.47x + 1.1, r = 0.70), Th1 (y = 0.53x + 1.0, r = 0.71), Th2 (y = 0.62x + 0.86, r = 0.73), Em1 (y = 0.82x + 0.86, r = 0.77), and Em2 (y = 0.72x + 0.84, r = 0.75). All corrected methods were not significantly different from microspheres, while uncorrected MBF values were significantly lower. For the top 50% of microsphere MBF values, flows were significantly underestimated by uncorrected SI (31%), Th1 (25%), and Th2 (19%), while Em1 (1%), and Em2 (9%) were similar to microsphere MBF. Myocardial signal saturation should be corrected prior to flow modeling to avoid underestimation of MBF by MR perfusion imaging.

  17. Cardiac contraction motion compensation in gated myocardial perfusion SPECT: A comparative study.

    PubMed

    Salehi, Narges; Rahmim, Arman; Fatemizadeh, Emad; Akbarzadeh, Afshin; Farahani, Mohammad Hossein; Farzanefar, Saeed; Ay, Mohammad Reza

    2018-05-01

    Cardiac contraction significantly degrades quality and quantitative accuracy of gated myocardial perfusion SPECT (MPS) images. In this study, we aimed to explore different techniques in motion-compensated temporal processing of MPS images and their impact on image quality and quantitative accuracy. 50 patients without known heart condition underwent gated MPS. 3D motion compensation methods using Motion Freezing by Cedars Sinai (MF), Log-domain Diffeomorphic Demons (LDD) and Free-Form Deformation (FFD) were applied to warp all image phases to fit the end-diastolic (ED) phase. Afterwards, myocardial wall thickness, myocardial to blood pool contrast, and image contrast-to noise ratio (CNR) were measured in summed images with no motion compensation (NoMC) and compensated images (MF, LDD and FFD). Total Perfusion Defect (TPD) was derived from Cedars-Sinai software, on the basis of sex-specific normal limits. Left ventricle (LV) lateral wall thickness was reduced after applying motion compensation (p < 0.05). Myocardial to blood pool contrast and CNR in compensated images were greater than NoMC (p < 0.05). TPD_LDD was in good agreement with the corresponding TPD_MF (p = 0.13). All methods have improved image quality and quantitative performance relative to NoMC. LDD and FFD are fully automatic and do not require any manual intervention, while MF is dependent on contour definition. In terms of diagnostic parameters LDD is in good agreement with MF which is a clinically accepted method. Further investigation along with diagnostic reference standards, in order to specify diagnostic value of each technique is recommended. Copyright © 2018 Associazione Italiana di Fisica Medica. All rights reserved.

  18. Impact of myocardial viability assessed by myocardial perfusion imaging on ventricular tachyarrhythmias in cardiac resynchronization therapy.

    PubMed

    Žižek, David; Cvijić, Marta; Ležaić, Luka; Salobir, Barbara Gužič; Zupan, Igor

    2013-12-01

    The presence of myocardial fibrosis is associated with ventricular tachyarrhythmia (VT) occurrence irrespective of cardiomyopathy etiology. The aim of our study was to evaluate the impact of global and regional viability on VTs in patients undergoing cardiac resynchronization therapy (CRT). Fifty-seven patients with advanced heart failure (age 62.3 ± 10.2; 38 men; 24 ischemic etiology) were evaluated using single-photon emission computed tomography myocardial perfusion imaging before CRT defibrillator device implantation. Global myocardial viability was determined by the number of viable segments in a 20-segment model. Regional viability was calculated as the mean tracer activity in the corresponding segments at left ventricular (LV) lead position. LV lead segments were determined at implant venography using 2 projections (left anterior oblique 30 and right anterior oblique 30) of coronary sinus tributaries. Patients were followed 30 (24-34) months for the occurrence of VTs. VTs were registered in 18 patients (31.6%). Patients without VTs had significantly more viable segments (17.6 ± 2.35 vs 14.2 ± 4.0; P = .002) and higher regional myocardial viability at LV lead position (66.1% ± 10.3% vs 54.8% ± 11.4% of tracer activity; P = .001) than those with VTs. In multivariate logistic regression models, the number of viable segments (OR = 0.66; 95% confidence interval (CI) 0.53-0.85; P = .001) and regional viability (OR = 0.90; 95% CI 0.85-0.97; P = .003) were the only independent predictors of VT occurrence. Global and regional myocardial viability are independently related to the occurrence of VTs in patients after CRT.

  19. Associations Between Fibrocytes and Postcontrast Myocardial T1 Times in Hypertrophic Cardiomyopathy

    PubMed Central

    Fang, Lu; Beale, Anna; Ellims, Andris H.; Moore, Xiao‐lei; Ling, Liang‐han; Taylor, Andrew J.; Chin‐Dusting, Jaye; Dart, Anthony M.

    2013-01-01

    Background Fibrocytes are bone marrow‐derived mesenchymal progenitors that have been linked to various fibrotic disorders. This study was undertaken to investigate whether fibrocytes are increased in diffuse myocardial fibrosis in humans. Methods and Results Thirty‐seven patients with hypertrophic cardiomyopathy (HCM) and 20 healthy controls were recruited. Cardiac magnetic resonance imaging with postcontrast T1 mapping was performed to non‐invasively quantify diffuse myocardial fibrosis and these patients were classified into 2 groups (T1<470 ms or T1≥470 ms, as likely or unlikely to have diffuse fibrosis, respectively). Circulating fibrocytes (CD45+/CD34+/collagen I+) were measured by flow cytometry. Peripheral blood mononuclear cells (PBMCs) were cultured for 13 days and fibrocytes were quantitated by flow cytometry (CD45+/collagen I+) and real‐time PCR (gene expression of matrix proteins). Plasma cytokines/chemokines mediating fibrocyte trafficking and differentiation were measured by multiplex assays. Circulating fibrocytes were decreased in HCM patients compared to controls. The proportion of fibrocytes derived from PBMCs was increased in patients with diffuse fibrosis compared with those without or controls (31.1±4.1% versus 18.9±3.9% and 10.9±2.0%, P<0.05 and P<0.001, respectively), and the proportion of fibrocytes was inversely correlated with T1 time (r=−0.37, P=0.03). Plasma levels of stromal cell‐derived factor‐1 were elevated in patients with diffuse fibrosis compared with those without or controls (5131±271 pg/mL versus 3893±356 pg/mL and 4172±185 pg/mL, respectively, both P<0.05). Conclusions HCM patients with diffuse fibrosis as assessed by postcontrast T1 mapping have elevated plasma SDF and an enhanced ability of PBMCs to differentiate into fibrocytes, suggesting that fibrocytes may contribute to the pathogenesis of myocardial fibrosis. PMID:24125844

  20. Fully automatic registration and segmentation of first-pass myocardial perfusion MR image sequences.

    PubMed

    Gupta, Vikas; Hendriks, Emile A; Milles, Julien; van der Geest, Rob J; Jerosch-Herold, Michael; Reiber, Johan H C; Lelieveldt, Boudewijn P F

    2010-11-01

    Derivation of diagnostically relevant parameters from first-pass myocardial perfusion magnetic resonance images involves the tedious and time-consuming manual segmentation of the myocardium in a large number of images. To reduce the manual interaction and expedite the perfusion analysis, we propose an automatic registration and segmentation method for the derivation of perfusion linked parameters. A complete automation was accomplished by first registering misaligned images using a method based on independent component analysis, and then using the registered data to automatically segment the myocardium with active appearance models. We used 18 perfusion studies (100 images per study) for validation in which the automatically obtained (AO) contours were compared with expert drawn contours on the basis of point-to-curve error, Dice index, and relative perfusion upslope in the myocardium. Visual inspection revealed successful segmentation in 15 out of 18 studies. Comparison of the AO contours with expert drawn contours yielded 2.23 ± 0.53 mm and 0.91 ± 0.02 as point-to-curve error and Dice index, respectively. The average difference between manually and automatically obtained relative upslope parameters was found to be statistically insignificant (P = .37). Moreover, the analysis time per slice was reduced from 20 minutes (manual) to 1.5 minutes (automatic). We proposed an automatic method that significantly reduced the time required for analysis of first-pass cardiac magnetic resonance perfusion images. The robustness and accuracy of the proposed method were demonstrated by the high spatial correspondence and statistically insignificant difference in perfusion parameters, when AO contours were compared with expert drawn contours. Copyright © 2010 AUR. Published by Elsevier Inc. All rights reserved.

  1. Non-contrast T1-mapping detects acute myocardial edema with high diagnostic accuracy: a comparison to T2-weighted cardiovascular magnetic resonance

    PubMed Central

    2012-01-01

    Background T2w-CMR is used widely to assess myocardial edema. Quantitative T1-mapping is also sensitive to changes in free water content. We hypothesized that T1-mapping would have a higher diagnostic performance in detecting acute edema than dark-blood and bright-blood T2w-CMR. Methods We investigated 21 controls (55 ± 13 years) and 21 patients (61 ± 10 years) with Takotsubo cardiomyopathy or acute regional myocardial edema without infarction. CMR performed within 7 days included cine, T1-mapping using ShMOLLI, dark-blood T2-STIR, bright-blood ACUT2E and LGE imaging. We analyzed wall motion, myocardial T1 values and T2 signal intensity (SI) ratio relative to both skeletal muscle and remote myocardium. Results All patients had acute cardiac symptoms, increased Troponin I (0.15-36.80 ug/L) and acute wall motion abnormalities but no LGE. T1 was increased in patient segments with abnormal and normal wall motion compared to controls (1113 ± 94 ms, 1029 ± 59 ms and 944 ± 17 ms, respectively; p < 0.001). T2 SI ratio using STIR and ACUT2E was also increased in patient segments with abnormal and normal wall motion compared to controls (all p < 0.02). Receiver operator characteristics analysis showed that T1-mapping had a significantly larger area-under-the-curve (AUC = 0.94) compared to T2-weighted methods, whether the reference ROI was skeletal muscle or remote myocardium (AUC = 0.58-0.89; p < 0.03). A T1 value of greater than 990 ms most optimally differentiated segments affected by edema from normal segments at 1.5 T, with a sensitivity and specificity of 92 %. Conclusions Non-contrast T1-mapping using ShMOLLI is a novel method for objectively detecting myocardial edema with a high diagnostic performance. T1-mapping may serve as a complementary technique to T2-weighted imaging for assessing myocardial edema in ischemic and non-ischemic heart disease, such as quantifying area-at-risk and diagnosing

  2. Septal and Anterior Reverse Mismatch of Myocardial Perfusion and Metabolism in Patients With Coronary Artery Disease and Left Bundle Branch Block

    PubMed Central

    Wang, Jian-Guang; Fang, Wei; Yang, Min-Fu; Tian, Yue-Qin; Zhang, Xiao-Li; Shen, Rui; Sun, Xiao-Xin; Guo, Feng; Wang, Dao-Yu; He, Zuo-Xiang

    2015-01-01

    Abstract The effects of left bundle branch block (LBBB) on left ventricular myocardial metabolism have not been well investigated. This study evaluated these effects in patients with coronary artery disease (CAD). Sixty-five CAD patients with complete LBBB (mean age, 61.8 ± 9.7 years) and 65 without LBBB (mean age, 59.9 ± 8.4 years) underwent single photon emission computed tomography, positron emission tomography, and contrast coronary angiography. The relationship between myocardial perfusion and metabolism and reverse mismatch score, and that between QRS length and reverse mismatch score and wall motion score were evaluated. The incidence of left ventricular septum and anterior wall reverse mismatching between the two groups was significantly different (P < 0.001 and P = 0.002, respectively). The incidences of normal myocardial perfusion and metabolism in the left ventricular lateral and inferior walls were also significantly different between the two groups (P < 0.001 and P < 0.001, respectively). The incidence of septal reverse mismatching in patients with mild to moderate perfusion was significantly higher among those with LBBB than among those without LBBB (P < 0.001). In CAD patients with LBBB, septal reverse mismatching was significantly more common among those with mild to moderate perfusion than among those with severe perfusion defects (P = 0.002). The correlation between the septal reverse mismatch score and QRS length was significant (P = 0.026). In patients with CAD and LBBB, septal and anterior reverse mismatching of myocardial perfusion and metabolism was frequently present; the septal reverse mismatch score negatively correlated with the QRS interval. PMID:25997045

  3. Quantitative evaluation of ischemic myocardial scar tissue by unenhanced T1 mapping using 3.0 Tesla MR scanner

    PubMed Central

    Okur, Aylin; Kantarcı, Mecit; Kızrak, Yeşim; Yıldız, Sema; Pirimoğlu, Berhan; Karaca, Leyla; Oğul, Hayri; Sevimli, Serdar

    2014-01-01

    PURPOSE We aimed to use a noninvasive method for quantifying T1 values of chronic myocardial infarction scar by cardiac magnetic resonance imaging (MRI), and determine its diagnostic performance. MATERIALS AND METHODS We performed cardiac MRI on 29 consecutive patients with known coronary artery disease (CAD) on 3.0 Tesla MRI scanner. An unenhanced T1 mapping technique was used to calculate T1 relaxation time of myocardial scar tissue, and its diagnostic performance was evaluated. Chronic scar tissue was identified by delayed contrast-enhancement (DE) MRI and T2-weighted images. Sensitivity, specificity, and accuracy values were calculated for T1 mapping using DE images as the gold standard. RESULTS Four hundred and forty-two segments were analyzed in 26 patients. While myocardial chronic scar was demonstrated in 45 segments on DE images, T1 mapping MRI showed a chronic scar area in 54 segments. T1 relaxation time was higher in chronic scar tissue, compared with remote areas (1314±98 ms vs. 1099±90 ms, P < 0.001). Therefore, increased T1 values were shown in areas of myocardium colocalized with areas of DE and normal signal on T2-weighted images. There was a significant correlation between T1 mapping and DE images in evaluation of myocardial wall injury extent (P < 0.05). We calculated sensitivity, specificity, and accuracy as 95.5%, 97%, and 96%, respectively. CONCLUSION The results of the present study reveal that T1 mapping MRI combined with T2-weighted images might be a feasible imaging modality for detecting chronic myocardial infarction scar tissue. PMID:25010366

  4. Novel cardiac magnetic resonance biomarkers: native T1 and extracellular volume myocardial mapping.

    PubMed

    Cannaò, Paola Maria; Altabella, Luisa; Petrini, Marcello; Alì, Marco; Secchi, Francesco; Sardanelli, Francesco

    2016-04-28

    Cardiac magnetic resonance (CMR) is a non-invasive diagnostic tool playing a key role in the assessment of cardiac morphology and function as well as in tissue characterization. Late gadolinium enhancement is a fundamental CMR technique for detecting focal or regional abnormalities such as scar tissue, replacement fibrosis, or inflammation using qualitative, semi-quantitative, or quantitative methods, but not allowing for evaluating the whole myocardium in the presence of diffuse disease. The novel T1 mapping approach permits a quantitative assessment of the entire myocardium providing a voxel-by-voxel map of native T1 relaxation time, obtained before the intravenous administration of gadolinium-based contrast material. Combining T1 data obtained before and after contrast injection, it is also possible to calculate the voxel-by-voxel extracellular volume (ECV), resulting in another myocardial parametric map. This article describes technical challenges and clinical perspectives of these two novel CMR biomarkers: myocardial native T1 and ECV mapping.

  5. Multicenter evaluation of stress-first myocardial perfusion image triage by nuclear technologists and automated quantification.

    PubMed

    Chaudhry, Waseem; Hussain, Nasir; Ahlberg, Alan W; Croft, Lori B; Fernandez, Antonio B; Parker, Mathew W; Swales, Heather H; Slomka, Piotr J; Henzlova, Milena J; Duvall, W Lane

    2017-06-01

    A stress-first myocardial perfusion imaging (MPI) protocol saves time, is cost effective, and decreases radiation exposure. A limitation of this protocol is the requirement for physician review of the stress images to determine the need for rest images. This hurdle could be eliminated if an experienced technologist and/or automated computer quantification could make this determination. Images from consecutive patients who were undergoing a stress-first MPI with attenuation correction at two tertiary care medical centers were prospectively reviewed independently by a technologist and cardiologist blinded to clinical and stress test data. Their decision on the need for rest imaging along with automated computer quantification of perfusion results was compared with the clinical reference standard of an assessment of perfusion images by a board-certified nuclear cardiologist that included clinical and stress test data. A total of 250 patients (mean age 61 years and 55% female) who underwent a stress-first MPI were studied. According to the clinical reference standard, 42 (16.8%) and 208 (83.2%) stress-first images were interpreted as "needing" and "not needing" rest images, respectively. The technologists correctly classified 229 (91.6%) stress-first images as either "needing" (n = 28) or "not needing" (n = 201) rest images. Their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 66.7%, 96.6%, 80.0%, and 93.5%, respectively. An automated stress TPD score ≥1.2 was associated with optimal sensitivity and specificity and correctly classified 179 (71.6%) stress-first images as either "needing" (n = 31) or "not needing" (n = 148) rest images. Its sensitivity, specificity, PPV, and NPV were 73.8%, 71.2%, 34.1%, and 93.1%, respectively. In a model whereby the computer or technologist could correct for the other's incorrect classification, 242 (96.8%) stress-first images were correctly classified. The composite

  6. Multicenter evaluation of stress-first myocardial perfusion image triage by nuclear technologists and automated quantification

    PubMed Central

    Chaudhry, Waseem; Hussain, Nasir; Ahlberg, Alan W.; Croft, Lori B.; Fernandez, Antonio B.; Parker, Mathew W.; Swales, Heather H.; Slomka, Piotr J.; Henzlova, Milena J.; Duvall, W. Lane

    2016-01-01

    Background A stress-first myocardial perfusion imaging (MPI) protocol saves time, is cost effective, and decreases radiation exposure. A limitation of this protocol is the requirement for physician review of the stress images to determine the need for rest images. This hurdle could be eliminated if an experienced technologist and/or automated computer quantification could make this determination. Methods Images from consecutive patients who were undergoing a stress-first MPI with attenuation correction at two tertiary care medical centers were prospectively reviewed independently by a technologist and cardiologist blinded to clinical and stress test data. Their decision on the need for rest imaging along with automated computer quantification of perfusion results was compared with the clinical reference standard of an assessment of perfusion images by a board-certified nuclear cardiologist that included clinical and stress test data. Results A total of 250 patients (mean age 61 years and 55% female) who underwent a stress-first MPI were studied. According to the clinical reference standard, 42 (16.8%) and 208 (83.2%) stress-first images were interpreted as “needing” and “not needing” rest images, respectively. The technologists correctly classified 229 (91.6%) stress-first images as either “needing” (n = 28) or “not needing” (n = 201) rest images. Their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 66.7%, 96.6%, 80.0%, and 93.5%, respectively. An automated stress TPD score ≥1.2 was associated with optimal sensitivity and specificity and correctly classified 179 (71.6%) stress-first images as either “needing” (n = 31) or “not needing” (n = 148) rest images. Its sensitivity, specificity, PPV, and NPV were 73.8%, 71.2%, 34.1%, and 93.1%, respectively. In a model whereby the computer or technologist could correct for the other's incorrect classification, 242 (96.8%) stress-first images were

  7. Myocardial perfusion quantification using simultaneously acquired 13 NH3 -ammonia PET and dynamic contrast-enhanced MRI in patients at rest and stress.

    PubMed

    Kunze, Karl P; Nekolla, Stephan G; Rischpler, Christoph; Zhang, Shelley HuaLei; Hayes, Carmel; Langwieser, Nicolas; Ibrahim, Tareq; Laugwitz, Karl-Ludwig; Schwaiger, Markus

    2018-04-19

    Systematic differences with respect to myocardial perfusion quantification exist between DCE-MRI and PET. Using the potential of integrated PET/MRI, this study was conceived to compare perfusion quantification on the basis of simultaneously acquired 13 NH 3 -ammonia PET and DCE-MRI data in patients at rest and stress. Twenty-nine patients were examined on a 3T PET/MRI scanner. DCE-MRI was implemented in dual-sequence design and additional T 1 mapping for signal normalization. Four different deconvolution methods including a modified version of the Fermi technique were compared against 13 NH 3 -ammonia results. Cohort-average flow comparison yielded higher resting flows for DCE-MRI than for PET and, therefore, significantly lower DCE-MRI perfusion ratios under the common assumption of equal arterial and tissue hematocrit. Absolute flow values were strongly correlated in both slice-average (R 2  = 0.82) and regional (R 2  = 0.7) evaluations. Different DCE-MRI deconvolution methods yielded similar flow result with exception of an unconstrained Fermi method exhibiting outliers at high flows when compared with PET. Thresholds for Ischemia classification may not be directly tradable between PET and MRI flow values. Differences in perfusion ratios between PET and DCE-MRI may be lifted by using stress/rest-specific hematocrit conversion. Proper physiological constraints are advised in model-constrained deconvolution. © 2018 International Society for Magnetic Resonance in Medicine.

  8. A hypertensive response to exercise is associated with transient ischemic dilation on myocardial perfusion SPECT imaging.

    PubMed

    Smelley, Matthew P; Virnich, Daniel E; Williams, Kim A; Ward, R Parker

    2007-07-01

    A hypertensive response to exercise (HRE) is associated with false-positive stress echocardiograms and myocardial perfusion single photon emission computed tomography (myocardial perfusion imaging [MPI]) defects even in the absence of coronary artery disease (CAD). Transient ischemic dilation (TID) of the left ventricle on stress MPI is a marker of severe CAD and future cardiac events. This study evaluated the association between an HRE and TID. Blinded quantitative TID assessment was performed in 125 patients who had an HRE and a summed stress score (SSS) of less than 4, as well as 125 control patients with an SSS of less than 4 and without an HRE matched for age, gender, and resting systolic blood pressure. Cardiac comorbidities, pretest Framingham risk, and exercise results were recorded. TID was defined as a stress-to-rest volume ratio of 1.22 or greater. An HRE was associated with a high prevalence of TID and significantly more TID than no HRE (25.6% vs 11.2%; odds ratio, 3.00 [95% confidence interval, 1.41-6.38]). TID was more prevalent even in subgroups with a low pretest probability CAD, including those without diabetes mellitus or angina. On conditional logistic regression analysis, an HRE was found to be independently associated with TID after consideration of other clinical and exercise MPI variables (odds ratio, 2.72 [95% confidence interval, 1.01-7.31]). An HRE is associated with a high prevalence of TID in patients without other significant perfusion defects, possibly as a result of global subendocardial ischemia induced by the HRE.

  9. Diagnostic accuracy and functional parameters of myocardial perfusion scintigraphy using accelerated cardiac acquisition with IQ SPECT technique in comparison to conventional imaging.

    PubMed

    Pirich, Christian; Keinrath, Peter; Barth, Gabriele; Rendl, Gundula; Rettenbacher, Lukas; Rodrigues, Margarida

    2017-03-01

    IQ SPECT consists of a new pinhole-like collimator, cardio-centric acquisition, and advanced 3D iterative SPECT reconstruction. The aim of this paper was to compare diagnostic accuracy and functional parameters obtained with IQ SPECT versus conventional SPECT in patients undergoing myocardial perfusion scintigraphy with adenosine stress and at rest. Eight patients with known or suspected coronary artery disease underwent [99mTc] tetrofosmin gated SPECT. Acquisition was performed on a Symbia T6 equipped with IQ SPECT and on a conventional gamma camera system. Gated SPECT data were used to calculate functional parameters. Scores analysis was performed on a 17-segment model. Coronary angiography and clinical follow-up were considered as diagnostic reference standard. Mean acquisition time was 4 minutes with IQ SPECT and 21 minutes with conventional SPECT. Agreement degree on the diagnostic accuracy between both systems was 0.97 for stress studies, 0.91 for rest studies and 0.96 for both studies. Perfusion abnormalities scores obtained by using IQ SPECT and conventional SPECT were not significant different: SSS, 9.7±8.8 and 10.1±6.4; SRS, 7.1±6.1 and 7.5±7.3; SDS, 4.0±6.1 and 3.9±4.3, respectively. However, a significant difference was found in functional parameters derived from IQ SPECT and conventional SPECT both after stress and at rest. Mean LVEF was 8% lower using IQ SPECT. Differences in LVEF were found in patients with normal LVEF and patients with reduced LVEF. Functional parameters using accelerated cardiac acquisition with IQ SPECT are significantly different to those obtained with conventional SPECT, while agreement for clinical interpretation of myocardial perfusion scintigraphy with both techniques is high.

  10. Energy demand of cardioplegically perfused human hearts.

    PubMed

    Preusse, C J; Winter, J; Schulte, H D; Bircks, W

    1985-01-01

    Human adult hearts with aortic valve disease (n = 20) and hypertrophic obstructive cardiomyopathy (n = 1) were perfused intraoperatively with cold histidine buffered Bretschneider solution. During a seven minute cardioplegic perfusion the temperature level, the electrolyte level, the resistance of the left (LCA) and right coronary artery (RCA), and myocardial O2 consumption were analysed. Equilibration of K+ was terminated shortly after the start of the perfusion while Na+ equilibration lasted for about 5 minutes. Resistance of RCA did not change significantly, but that of the LCA was diminished significantly (p less than 0.025) within the perfusion period indicating a delayed washout of calcium from the extracellular space. Myocardial O2 consumption was reduced from 2.71 ml/min (1. minute) to 1.51 ml/min (4. minute) to 0.93 ml/min (7. minute) although the temperature had reached a low level after 3 minutes. The difference between 4. to 7. minutes is significant (p less than 0.001). By our results it is concluded that in adult hearts high-volume cardioplegic perfusion at a flow rate of 1 ml/min X gm at a perfusion pressure of 40 to 50 mmHg should be performed for at least 6 to 7 minutes to achieve a sufficient intra-ischemic myocardial protection.

  11. Evaluation of the novel myocardial perfusion positron-emission tomography tracer 18F-BMS-747158-02: comparison to 13N-ammonia and validation with microspheres in a pig model.

    PubMed

    Nekolla, S G; Reder, S; Saraste, A; Higuchi, T; Dzewas, G; Preissel, A; Huisman, M; Poethko, T; Schuster, T; Yu, M; Robinson, S; Casebier, D; Henke, J; Wester, H J; Schwaiger, M

    2009-05-05

    Positron-emission tomography (PET) tracers for myocardial perfusion are commonly labeled with short-lived isotopes that limit their widespread clinical use. 18F-BMS-747158-02 (18F-BMS) is a novel pyridaben derivative that was evaluated for assessment of myocardial perfusion by comparison with 13N-ammonia (13NH3) and with radioactive microspheres in a pig model. Fourteen pigs injected with 500 MBq of 13NH3 or 100 to 200 MBq of 18F-BMS underwent dynamic PET at rest and during pharmacological stress. In 8 of these pigs, 18F-BMS was injected during stress combined with transient, 2.5-minute constriction of the left anterior descending coronary artery. Radioactive microspheres were coinjected with 18F-BMS. Ratios of myocardial tracer uptake to surrounding tissues were determined, and myocardial blood flow was quantified by compartmental modeling. Both tracers showed high and homogeneous myocardial uptake. Compared with 13NH3, 18F-BMS showed higher activity ratios between myocardium and blood (rest 2.5 versus 4.1; stress 2.1 versus 5.8), liver (rest 1.2 versus 1.8; stress 0.7 versus 2.0), and lungs (rest 2.5 versus 4.2; stress 2.9 versus 6.4). Regional myocardial blood flow assessed with 18F-BMS PET showed good correlation (r=0.88, slope=0.84) and agreement (mean difference -0.10 [25th percentile -0.3, 75th percentile 0.1 mL x min(-1) x g(-1)]) with that measured with radioactive microspheres over a flow range from 0.1 to 3.0 mL x min(-1) x g(-1). The extent of defects induced by left anterior descending coronary artery constriction measured by 18F-BMS and microspheres also correlated closely (r=0.63, slope=1.1). 18F-BMS-747158-02 is a very attractive new PET perfusion tracer that allows quantitative assessment of regional myocardial perfusion over a wide flow range. The long half-life of 18F renders this tracer useful for clinical PET/CT applications in the workup of patients with suspected or proven coronary artery disease.

  12. Quantification of myocardial blood flow with dynamic perfusion 3.0 Tesla MRI: Validation with (15) O-water PET.

    PubMed

    Tomiyama, Yuuki; Manabe, Osamu; Oyama-Manabe, Noriko; Naya, Masanao; Sugimori, Hiroyuki; Hirata, Kenji; Mori, Yuki; Tsutsui, Hiroyuki; Kudo, Kohsuke; Tamaki, Nagara; Katoh, Chietsugu

    2015-09-01

    To develop and validate a method for quantifying myocardial blood flow (MBF) using dynamic perfusion magnetic resonance imaging (MBFMRI ) at 3.0 Tesla (T) and compare the findings with those of (15) O-water positron emission tomography (MBFPET ). Twenty healthy male volunteers underwent magnetic resonance imaging (MRI) and (15) O-water positron emission tomography (PET) at rest and during adenosine triphosphate infusion. The single-tissue compartment model was used to estimate the inflow rate constant (K1). We estimated the extraction fraction of Gd-DTPA using K1 and MBF values obtained from (15) O-water PET for the first 10 subjects. For validation, we calculated MBFMRI values for the remaining 10 subjects and compared them with the MBFPET values. In addition, we compared MBFMRI values of 10 patients with coronary artery disease with those of healthy subjects. The mean resting and stress MBFMRI values were 0.76 ± 0.10 and 3.04 ± 0.82 mL/min/g, respectively, and showed excellent correlation with the mean MBFPET values (r = 0.96, P < 0.01). The mean stress MBFMRI value was significantly lower for the patients (1.92 ± 0.37) than for the healthy subjects (P < 0.001). The use of dynamic perfusion MRI at 3T is useful for estimating MBF and can be applied for patients with coronary artery disease. © 2014 Wiley Periodicals, Inc.

  13. Stress Perfusion Cardiac Magnetic Resonance Imaging Effectively Risk Stratifies Diabetic Patients With Suspected Myocardial Ischemia.

    PubMed

    Heydari, Bobak; Juan, Yu-Hsiang; Liu, Hui; Abbasi, Siddique; Shah, Ravi; Blankstein, Ron; Steigner, Michael; Jerosch-Herold, Michael; Kwong, Raymond Y

    2016-04-01

    Diabetics remain at high risk of cardiovascular disease and mortality despite advancements in medical therapy. Noninvasive cardiac risk profiling is often more difficult in diabetics owing to the prevalence of silent ischemia with unrecognized myocardial infarction, reduced exercise capacity, nondiagnostic electrocardiographic changes, and balanced ischemia from diffuse epicardial coronary atherosclerosis and microvascular dysfunction. A consecutive cohort of 173 patients with diabetes mellitus (mean age, 61.7±11.9 years; 37% women) with suspected myocardial ischemia underwent stress perfusion cardiac magnetic resonance imaging. Patients were evaluated for adverse cardiac events after cardiac magnetic resonance imaging with mean follow-up time of 2.9±2.5 years. Mean hemoglobin A1c for the population was 7.9±1.8%. Primary end point was a composite of cardiac death and nonfatal myocardial infarction. Diabetics with no inducible ischemia (n=94) experienced an annualized event rate of 1.4% compared with 8.2% (P=0.0003) in those with inducible ischemia (n=79). Diabetics without late gadolinium enhancement or inducible ischemia had a low annual cardiac event rate (0.5% per year). The presence of inducible ischemia was the strongest unadjusted predictor (hazard ratio, 4.86; P<0.01) for cardiac death and nonfatal myocardial infarction. This association remained robust in adjusted stepwise multivariable Cox regression analysis (hazard ratio, 4.28; P=0.02). In addition, categorical net reclassification index using 5-year risk cutoffs of 5% and 10% resulted in reclassification of 43.4% of the diabetic cohort with net reclassification index of 0.38 (95% confidence interval, 0.20-0.56; P<0.0001). Stress perfusion cardiac magnetic resonance imaging provided independent prognostic utility and effectively reclassified risk in patients with diabetes mellitus referred for ischemic assessment. Further evaluation is required to determine whether a noninvasive imaging strategy with

  14. Measurement of myocardial blood flow by cardiovascular magnetic resonance perfusion: comparison of distributed parameter and Fermi models with single and dual bolus.

    PubMed

    Papanastasiou, Giorgos; Williams, Michelle C; Kershaw, Lucy E; Dweck, Marc R; Alam, Shirjel; Mirsadraee, Saeed; Connell, Martin; Gray, Calum; MacGillivray, Tom; Newby, David E; Semple, Scott Ik

    2015-02-17

    Mathematical modeling of cardiovascular magnetic resonance perfusion data allows absolute quantification of myocardial blood flow. Saturation of left ventricle signal during standard contrast administration can compromise the input function used when applying these models. This saturation effect is evident during application of standard Fermi models in single bolus perfusion data. Dual bolus injection protocols have been suggested to eliminate saturation but are much less practical in the clinical setting. The distributed parameter model can also be used for absolute quantification but has not been applied in patients with coronary artery disease. We assessed whether distributed parameter modeling might be less dependent on arterial input function saturation than Fermi modeling in healthy volunteers. We validated the accuracy of each model in detecting reduced myocardial blood flow in stenotic vessels versus gold-standard invasive methods. Eight healthy subjects were scanned using a dual bolus cardiac perfusion protocol at 3T. We performed both single and dual bolus analysis of these data using the distributed parameter and Fermi models. For the dual bolus analysis, a scaled pre-bolus arterial input function was used. In single bolus analysis, the arterial input function was extracted from the main bolus. We also performed analysis using both models of single bolus data obtained from five patients with coronary artery disease and findings were compared against independent invasive coronary angiography and fractional flow reserve. Statistical significance was defined as two-sided P value < 0.05. Fermi models overestimated myocardial blood flow in healthy volunteers due to arterial input function saturation in single bolus analysis compared to dual bolus analysis (P < 0.05). No difference was observed in these volunteers when applying distributed parameter-myocardial blood flow between single and dual bolus analysis. In patients, distributed parameter

  15. Normal myocardial perfusion scan portends a benign prognosis independent from the pretest probability of coronary artery disease. Sub-analysis of the J-ACCESS study.

    PubMed

    Imamura, Yosihiro; Fukuyama, Takaya; Nishimura, Sigeyuki; Nishimura, Tsunehiko

    2009-08-01

    We assessed the usefulness of gated stress/rest 99mTc-tetrofosmin myocardial perfusion single photon emission computed tomography (SPECT) to predict ischemic cardiac events in Japanese patients with various estimated pretest probabilities of coronary artery disease (CAD). Of the 4031 consecutively registered patients for a J-ACCESS (Japanese Assessment of Cardiac Events and Survival Study by Quantitative Gated SPECT) study, 1904 patients without prior cardiac events were selected. Gated stress/rest myocardial perfusion SPECT was performed and segmental perfusion scores and quantitative gated SPECT results were derived. The pretest probability for having CAD was estimated using the American College of Cardiology/American Heart Association/American College of Physicians-American Society of Internal Medicine guideline data for the management of patients with chronic stable angina, which includes age, gender, and type of chest discomfort. The patients were followed up for three years. During the three-year follow-up period, 96 developed ischemic cardiac events: 17 cardiac deaths, 8 nonfatal myocardial infarction, and 71 clinically driven revascularization. The summed stress score (SSS) was the most powerful independent predictor of all ischemic cardiac events (hazard ratio 1.077, CI 1.045-1.110). Abnormal SSS (> 3) was associated with a significantly higher cardiac event rate in patients with an intermediate to high pretest probability of CAD. Normal SSS (< or = 3) was associated with a low event rate in patients with any pretest probability of CAD. Myocardial perfusion SPECT is useful for further risk-stratification of patients with suspected CAD. The abnormal scan result (SSS > 3) is discriminative for subsequent cardiac events only in the groups with an intermediate to high pretest probability of CAD. The salient result is that normal scan results portend a benign prognosis independent from the pretest probability of CAD.

  16. High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P less than 0.00l). Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

  17. High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

    NASA Technical Reports Server (NTRS)

    Rahman, Atiar

    2006-01-01

    Background: Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). Methods and Results: 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P<0.001). Conclusions: Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

  18. Left ventricular eccentricity index measured with SPECT myocardial perfusion imaging: An additional parameter of adverse cardiac remodeling.

    PubMed

    Gimelli, Alessia; Liga, Riccardo; Clemente, Alberto; Marras, Gavino; Kusch, Annette; Marzullo, Paolo

    2017-01-12

    Single-photon emission computed-tomography (SPECT) allows the quantification of LV eccentricity index (EI), a measure of cardiac remodeling. We sought to evaluate the feasibility of EI measurement with SPECT myocardial perfusion imaging and its interactions with relevant LV functional and structural parameters. Four-hundred and fifty-six patients underwent myocardial perfusion imaging on a Cadmium-Zinc-Telluride (CZT) camera. The summed rest, stress, and difference scores were calculated. From rest images, the LV end-diastolic (EDV) and end-systolic volumes, ejection fraction (EF), and peak filling rate (PFR) were calculated. In every patient, the EI, ranging from 0 (sphere) to 1 (line), was computed using a dedicated software (QGS/QPS; Cedars-Sinai Medical Center). Three-hundred and thirty-eight/456 (74%) patients showed a normal EF (>50%), while 26% had LV systolic dysfunction. The EI was computed from CZT images with excellent reproducibility (interclass correlation coefficient: 0.99, 95% CI 0.98-0.99). More impaired EI values correlated with the presence of a more abnormal LV perfusion (P < .001), function (EF and PFR, P < .001), and structure (EDV, P < .001). On multivariate analysis, higher EDV (P < .001) and depressed EF (P = .014) values were independent predictors of abnormal EI. The evaluation of LV eccentricity is feasible on gated CZT images. Abnormal EI associates with significant cardiac structural and functional abnormalities.

  19. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision.

    PubMed

    Verberne, Hein J; Acampa, Wanda; Anagnostopoulos, Constantinos; Ballinger, Jim; Bengel, Frank; De Bondt, Pieter; Buechel, Ronny R; Cuocolo, Alberto; van Eck-Smit, Berthe L F; Flotats, Albert; Hacker, Marcus; Hindorf, Cecilia; Kaufmann, Philip A; Lindner, Oliver; Ljungberg, Michael; Lonsdale, Markus; Manrique, Alain; Minarik, David; Scholte, Arthur J H A; Slart, Riemer H J A; Trägårdh, Elin; de Wit, Tim C; Hesse, Birger

    2015-11-01

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines. A large number of minor changes have been described in more detail in the fully revised version available at the EANM home page: http://eanm.org/publications/guidelines/2015_07_EANM_FINAL_myocardial_perfusion_guideline.pdf .

  20. Cardiovascular outcomes after pharmacologic stress myocardial perfusion imaging.

    PubMed

    Lee, Douglas S; Husain, Mansoor; Wang, Xuesong; Austin, Peter C; Iwanochko, Robert M

    2016-04-01

    While pharmacologic stress single photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) is used for noninvasive evaluation of patients who are unable to perform treadmill exercise, its impact on net reclassification improvement (NRI) of prognosis is unknown. We evaluated the prognostic value of pharmacologic stress MPI for prediction of cardiovascular death or non-fatal myocardial infarction (MI) within 1 year at a single-center, university-based laboratory. We examined continuous and categorical NRI of pharmacologic SPECT-MPI for prediction of outcomes beyond clinical factors alone. Six thousand two hundred forty patients (median age 66 years [IQR 56-74], 3466 men) were studied and followed for 5963 person-years. SPECT-MPI variables associated with increased risk of cardiovascular death or non-fatal MI included summed stress score, stress ST-shift, and post-stress resting left ventricular ejection fraction ≤50%. Compared to a clinical model which included age, sex, cardiovascular disease, risk factors, and medications, model χ(2) (210.5 vs. 281.9, P < .001) and c-statistic (0.74 vs. 0.78, P < .001) were significantly increased by addition of SPECT-MPI predictors (summed stress score, stress ST-shift and stress resting left ventricular ejection fraction). SPECT-MPI predictors increased continuous NRI by 49.4% (P < .001), reclassifying 66.5% of patients as lower risk and 32.8% as higher risk of cardiovascular death or non-fatal MI. Addition of MPI predictors to clinical factors using risk categories, defined as <1%, 1% to 3%, and >3% annualized risk of cardiovascular death or non-fatal MI, yielded a 15.0% improvement in NRI (95% CI 7.6%-27.6%, P < .001). Pharmacologic stress MPI substantially improved net reclassification of cardiovascular death or MI risk beyond that afforded by clinical factors. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Promote quantitative ischemia imaging via myocardial perfusion CT iterative reconstruction with tensor total generalized variation regularization

    NASA Astrophysics Data System (ADS)

    Gu, Chengwei; Zeng, Dong; Lin, Jiahui; Li, Sui; He, Ji; Zhang, Hao; Bian, Zhaoying; Niu, Shanzhou; Zhang, Zhang; Huang, Jing; Chen, Bo; Zhao, Dazhe; Chen, Wufan; Ma, Jianhua

    2018-06-01

    Myocardial perfusion computed tomography (MPCT) imaging is commonly used to detect myocardial ischemia quantitatively. A limitation in MPCT is that an additional radiation dose is required compared to unenhanced CT due to its repeated dynamic data acquisition. Meanwhile, noise and streak artifacts in low-dose cases are the main factors that degrade the accuracy of quantifying myocardial ischemia and hamper the diagnostic utility of the filtered backprojection reconstructed MPCT images. Moreover, it is noted that the MPCT images are composed of a series of 2/3D images, which can be naturally regarded as a 3/4-order tensor, and the MPCT images are globally correlated along time and are sparse across space. To obtain higher fidelity ischemia from low-dose MPCT acquisitions quantitatively, we propose a robust statistical iterative MPCT image reconstruction algorithm by incorporating tensor total generalized variation (TTGV) regularization into a penalized weighted least-squares framework. Specifically, the TTGV regularization fuses the spatial correlation of the myocardial structure and the temporal continuation of the contrast agent intake during the perfusion. Then, an efficient iterative strategy is developed for the objective function optimization. Comprehensive evaluations have been conducted on a digital XCAT phantom and a preclinical porcine dataset regarding the accuracy of the reconstructed MPCT images, the quantitative differentiation of ischemia and the algorithm’s robustness and efficiency.

  2. Detection of right ventricular pressure overloading by thallium-201 myocardial scintigraphy. Results in 57 patients with chronic respiratory diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weitzenblum, E.; Moyses, B.; Dickele, M.C.

    1984-02-01

    The diagnostic value of thallium 201 (/sup 201/Tl) myocardial imaging was studied in 57 patients with chronic respiratory diseases, most with COPD (n . 46), by comparing the results to hemodynamic findings. In healthy subjects, the right ventricle (RV) is not visualized; therefore, any recorded activity of the RV was considered as indicating RV hypertrophy due to RV pressure overloading (RVPO). RV activity was graded from 0 (no activity) to 3 (activity greater than or equal to that of the left ventricle). Patients were divided into three groups according to the level of the pulmonary artery mean pressure (PPA): PPAmore » less than or equal to 20 mm Hg (no pulmonary arterial hypertension (PAH) ) . group 1, n . 20; PPA ranging from 21 to 30 mm Hg (mild to moderate PAH) . group 2, n . 20; PPA greater than 30 mm Hg (marked PAH) . group 3, n . 17. RV was visualized in 14 patients in group 3 (82 percent) and in 13 patients in group 2 (65 percent). For all patients with PAH (2 + 3) the sensitivity of /sup 201/Tl imaging for the diagnosis of RVPO was of 73 percent, higher than that of ECG and echocardiography (both 51 percent). The sensitivity of /sup 201/Tl, even if moderate (65 percent) was better than that of ECG (30 percent) or echo (40 percent) in patients with mild-to-moderate PAH (group 2). A high RV activity (grade 3) was observed in only three patients. The specificity of this method (obtained from results in group 1) was of 80 percent vs 89 percent for echo and 100 percent for ECG. These results suggest that 201Tl myocardial imaging is a rather sensitive method and could be of interest for the noninvasive diagnosis of RVPO in COPD patients.« less

  3. Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    NASA Astrophysics Data System (ADS)

    Salasiah, M.; Nordin, A. J.; Fathinul Fikri, A. S.; Hishar, H.; Tamchek, N.; Taiman, K.; Ahmad Bazli, A. K.; Abdul-Rashid, H. A.; Mahdiraji, G. A.; Mizanur, R.; Noor, Noramaliza M.

    2013-05-01

    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient's eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose.

  4. Design of a digital phantom population for myocardial perfusion SPECT imaging research

    NASA Astrophysics Data System (ADS)

    Ghaly, Michael; Du, Yong; Fung, George S. K.; Tsui, Benjamin M. W.; Links, Jonathan M.; Frey, Eric

    2014-06-01

    Digital phantoms and Monte Carlo (MC) simulations have become important tools for optimizing and evaluating instrumentation, acquisition and processing methods for myocardial perfusion SPECT (MPS). In this work, we designed a new adult digital phantom population and generated corresponding Tc-99m and Tl-201 projections for use in MPS research. The population is based on the three-dimensional XCAT phantom with organ parameters sampled from the Emory PET Torso Model Database. Phantoms included three variations each in body size, heart size, and subcutaneous adipose tissue level, for a total of 27 phantoms of each gender. The SimSET MC code and angular response functions were used to model interactions in the body and the collimator-detector system, respectively. We divided each phantom into seven organs, each simulated separately, allowing use of post-simulation summing to efficiently model uptake variations. Also, we adapted and used a criterion based on the relative Poisson effective count level to determine the required number of simulated photons for each simulated organ. This technique provided a quantitative estimate of the true noise in the simulated projection data, including residual MC simulation noise. Projections were generated in 1 keV wide energy windows from 48-184 keV assuming perfect energy resolution to permit study of the effects of window width, energy resolution, and crosstalk in the context of dual isotope MPS. We have developed a comprehensive method for efficiently simulating realistic projections for a realistic population of phantoms in the context of MPS imaging. The new phantom population and realistic database of simulated projections will be useful in performing mathematical and human observer studies to evaluate various acquisition and processing methods such as optimizing the energy window width, investigating the effect of energy resolution on image quality and evaluating compensation methods for degrading factors such as crosstalk in

  5. Normothermic machine perfusion of donor livers without the need for human blood products

    PubMed Central

    Matton, Alix P. M.; Burlage, Laura C.; van Rijn, Rianne; de Vries, Yvonne; Karangwa, Shanice A.; Nijsten, Maarten W.; Gouw, Annette S. H.; Wiersema‐Buist, Janneke; Adelmeijer, Jelle; Westerkamp, Andrie C.; Lisman, Ton

    2018-01-01

    Normothermic machine perfusion (NMP) enables viability assessment of donor livers prior to transplantation. NMP is frequently performed by using human blood products including red blood cells (RBCs) and fresh frozen plasma (FFP). Our aim was to examine the efficacy of a novel machine perfusion solution based on polymerized bovine hemoglobin‐based oxygen carrier (HBOC)‐201. Twenty‐four livers declined for transplantation were transported by using static cold storage. Upon arrival, livers underwent NMP for 6 hours using pressure‐controlled portal and arterial perfusion. A total of 12 livers were perfused using a solution based on RBCs and FFPs (historical cohort), 6 livers with HBOC‐201 and FFPs, and another 6 livers with HBOC‐201 and gelofusine, a gelatin‐based colloid solution. Compared with RBC + FFP perfused livers, livers perfused with HBOC‐201 had significantly higher hepatic adenosine triphosphate content, cumulative bile production, and portal and arterial flows. Biliary secretion of bicarbonate, bilirubin, bile salts, and phospholipids was similar in all 3 groups. The alanine aminotransferase concentration in perfusate was lower in the HBOC‐201perfused groups. In conclusion, NMP of human donor livers can be performed effectively using HBOC‐201 and gelofusine, eliminating the need for human blood products. Perfusing livers with HBOC‐201 is at least similar to perfusion with RBCs and FFP. Some of the biomarkers of liver function and injury even suggest a possible superiority of an HBOC‐201–based perfusion solution and opens a perspective for further optimization of machine perfusion techniques. Liver Transplantation 24 528–538 2018 AASLD. PMID:29281862

  6. Comparison of parathyroid hormone and G-CSF treatment after myocardial infarction on perfusion and stem cell homing.

    PubMed

    Huber, Bruno C; Fischer, Rebekka; Brunner, Stefan; Groebner, Michael; Rischpler, Christoph; Segeth, Alexander; Zaruba, Marc M; Wollenweber, Tim; Hacker, Marcus; Franz, Wolfgang-Michael

    2010-05-01

    Mobilization of stem cells by granulocyte colony-stimulating factor (G-CSF) was shown to have protective effects after myocardial infarction (MI); however, clinical trials failed to be effective. In search for alternative cytokines, parathyroid hormone (PTH) was recently shown to promote cardiac repair by enhanced neovascularization and cell survival. To compare the impact of the two cytokines G-CSF and PTH on myocardial perfusion, mice were noninvasively and repetitively investigated by pinhole single-photon emission computed tomography (SPECT) after MI. Mobilization and homing of bone marrow-derived stem cells (BMCs) was analyzed by fluorescence-activated cell sorter (FACS) analysis. Mice (C57BL/6J) were infarcted by left anterior descending artery ligation. PTH (80 mug/kg) and G-CSF (100 mug/kg) were injected for 5 days. Perfusion defects were determined by (99m)Tc-sestamibi SPECT at days 6 and 30 after MI. The number of BMCs characterized by Lin(-)/Sca-1(+)/c-kit(+) cells in peripheral blood and heart was analyzed by FACS. Both G-CSF and PTH treatment resulted in an augmented mobilization of BMCs in the peripheral blood. Contrary to G-CSF and controls, PTH and the combination showed significant migration of BMCs in ischemic myocardium associated with a significant reduction of perfusion defects from day 6 to day 30. A combination of both cytokines had no additional effects on migration and perfusion. In our preclinical model, SPECT analyses revealed the functional potential of PTH reducing size of infarction together with an enhanced homing of BMCs to the myocardium in contrast to G-CSF. A combination of both cytokines did not improve the functional outcome, suggesting clinical applications of PTH in ischemic heart diseases.

  7. Assessment of myocardial viability by dynamic tomographic iodine 123 iodophenylpentadecanoic acid imaging: comparison with rest-redistribution thallium 201 imaging.

    PubMed

    Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J

    1995-01-01

    This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.

  8. Detection and differentiation of early acute and following age stages of myocardial infarction with quantitative post-mortem cardiac 1.5T MR.

    PubMed

    Schwendener, Nicole; Jackowski, Christian; Persson, Anders; Warntjes, Marcel J; Schuster, Frederick; Riva, Fabiano; Zech, Wolf-Dieter

    2017-01-01

    Recently, quantitative MR sequences have started being used in post-mortem imaging. The goal of the present study was to evaluate if early acute and following age stages of myocardial infarction can be detected and discerned by quantitative 1.5T post-mortem cardiac magnetic resonance (PMCMR) based on quantitative T1, T2 and PD values. In 80 deceased individuals (25 female, 55 male), a cardiac MR quantification sequence was performed prior to cardiac dissection at autopsy in a prospective study. Focal myocardial signal alterations detected in synthetically generated MR images were MR quantified for their T1, T2 and PD values. The locations of signal alteration measurements in PMCMR were targeted at autopsy heart dissection and cardiac tissue specimens were taken for histologic examinations. Quantified signal alterations in PMCMR were correlated to their according histologic age stage of myocardial infarction. In PMCMR seventy-three focal myocardial signal alterations were detected in 49 of 80 investigated hearts. These signal alterations were diagnosed histologically as early acute (n=39), acute (n=14), subacute (n=10) and chronic (n=10) age stages of myocardial infarction. Statistical analysis revealed that based on their quantitative T1, T2 and PD values, a significant difference between all defined age groups of myocardial infarction can be determined. It can be concluded that quantitative 1.5T PMCMR quantification based on quantitative T1, T2 and PD values is feasible for characterization and differentiation of early acute and following age stages of myocardial infarction. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Quantitative diagnostic performance of myocardial perfusion SPECT with attenuation correction in women.

    PubMed

    Wolak, Arik; Slomka, Piotr J; Fish, Mathews B; Lorenzo, Santiago; Berman, Daniel S; Germano, Guido

    2008-06-01

    Attenuation correction (AC) for myocardial perfusion SPECT (MPS) had not been evaluated separately in women despite specific considerations in this group because of breast photon attenuation. We aimed to evaluate the performance of AC in women by using automated quantitative analysis of MPS to avoid any bias. Consecutive female patients--134 with a low likelihood (LLk) of coronary artery disease (CAD) and 114 with coronary angiography performed within less than 3 mo of MPS--who were referred for rest-stress electrocardiography-gated 99mTc-sestamibi MPS with AC were considered. Imaging data were evaluated for contour quality control. An additional 50 LLk studies in women were used to create equivalent normal limits for studies with AC and with no correction (NC). An experienced technologist unaware of the angiography and other results performed the contour quality control. All other processing was performed in a fully automated manner. Quantitative analysis was performed with the Cedars-Sinai myocardial perfusion analysis package. All automated segmental analyses were performed with the 17-segment, 5-point American Heart Association model. Summed stress scores (SSS) of > or =3 were considered abnormal. CAD (> or =70% stenosis) was present in 69 of 114 patients (60%). The normalcy rates were 93% for both NC and AC studies. The SSS for patients with CAD and without CAD for NC versus AC were 10.0 +/- 9.0 (mean +/- SD) versus 10.2 +/- 8.5 and 1.6 +/- 2.3 versus 1.8 +/- 2.5, respectively; P was not significant (NS) for all comparisons of NC versus AC. The SSS for LLk patients for NC versus AC were 0.51 +/- 1.0 versus 0.6 +/- 1.1, respectively; P was NS. The specificity for both NC and AC was 73%. The sensitivities for NC and AC were 80% and 81%, respectively, and the accuracies for NC and AC were 77% and 78%, respectively; P was NS for both comparisons. There are no significant diagnostic differences between automated quantitative MPS analyses performed in studies

  10. Myocardial Uptake of 7′-(Z)-[123I]Iodorotenone During Vasodilator Stress in Dogs With Critical Coronary Stenoses

    PubMed Central

    Broisat, Alexis; Ruiz, Mirta; Goodman, Norman C.; Hanrahan, Stephen M.; Reutter, Bryan W.; Brennan, Kathleen M.; Janabi, Mustafa; Schaefer, Saul; Watson, Denny D.; Beller, George A.; VanBrocklin, Henry F.; Glover, David K.

    2013-01-01

    Background There is a well-recognized need for a new generation of single photon emission computed tomography (SPECT) perfusion tracers with improved myocardial extraction over a wide flow range. Radiotracers that target complex I of the mitochondrial electron transport chain have been proposed as a new class of myocardial perfusion imaging agents. 7-(Z)-[125I]iodorotenone (125I-ZIROT) has demonstrated superior myocardial extraction and retention characteristics in rats and in isolated perfused rabbit hearts. We sought to fully characterize the biodistribution and myocardial extraction versus flow relationship of 123I-ZIROT in an intact large-animal model. Methods and Results The 123I-ZIROT was administered during adenosine A2A agonist-induced hyperemia in 5 anesthetized dogs with critical left anterior descending (LAD) stenoses. When left circumflex (LCx) flow was maximal, 123I-ZIROT and microspheres were coinjected and the dogs were euthanized 5 minutes later. 123I-ZIROT biodistribution was evaluated in 2 additional dogs by in vivo planar imaging. At 123I-ZIROT injection, transmural LAD flow was unchanged from baseline (mean±SEM, 0.90±0.22 versus 0.87±0.11 mL/[min · g]; P=0.92), whereas LCx zone flow increased significantly (mean±SEM, 3.25±0.51 versus 1.00±0.17 mL/[min · g]; P<0.05). Myocardial 123I-ZIROT extraction tracked regional myocardial flow better than either thallium-201 or 99mTc-sestamibi from previous studies using a similar model. Furthermore, the 123I-ZIROT LAD/LCx activity ratios by ex vivo imaging or well counting (mean±SEM, 0.42±0.08 and 0.45±0.1, respectively) only slightly underestimated the LAD/LCx microsphere flow ratio (0.32±0.09). Conclusions The ability of 123I-ZIROT to more linearly track blood flow over a wide range makes it a promising new SPECT myocardial perfusion imaging agent with potential for improved coronary artery disease detection and better quantitative estimation of the severity of flow impairment. PMID:21917783

  11. Diagnostic performance of dual-energy CT stress myocardial perfusion imaging: direct comparison with cardiovascular MRI.

    PubMed

    Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K

    2014-12-01

    The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.

  12. Double-gated myocardial ASL perfusion imaging is robust to heart rate variation.

    PubMed

    Do, Hung Phi; Yoon, Andrew J; Fong, Michael W; Saremi, Farhood; Barr, Mark L; Nayak, Krishna S

    2017-05-01

    Cardiac motion is a dominant source of physiological noise (PN) in myocardial arterial spin labeled (ASL) perfusion imaging. This study investigates the sensitivity to heart rate variation (HRV) of double-gated myocardial ASL compared with the more widely used single-gated method. Double-gating and single-gating were performed on 10 healthy volunteers (n = 10, 3F/7M; age, 23-34 years) and eight heart transplant recipients (n = 8, 1F/7M; age, 26-76 years) at rest in the randomized order. Myocardial blood flow (MBF), PN, temporal signal-to-noise ratio (SNR), and HRV were measured. HRV ranged from 0.2 to 7.8 bpm. Double-gating PN did not depend on HRV, while single-gating PN increased with HRV. Over all subjects, double-gating provided a significant reduction in global PN (from 0.20 ± 0.15 to 0.11 ± 0.03 mL/g/min; P = 0.01) and per-segment PN (from 0.33 ± 0.23 to 0.21 ± 0.12 mL/g/min; P < 0.001), with significant increases in global temporal SNR (from 11 ± 8 to 18 ± 8; P = 0.02) and per-segment temporal SNR (from 7 ± 4 to 11 ± 12; P < 0.001) without significant difference in measured MBF. Single-gated myocardial ASL suffers from reduced temporal SNR, while double-gated myocardial ASL provides consistent temporal SNR independent of HRV. Magn Reson Med 77:1975-1980, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  13. [Intracoronary, human autologous stem cell transplantation for myocardial regeneration following myocardial infarction].

    PubMed

    Strauer, B E; Brehm, M; Zeus, T; Gattermann, N; Hernandez, A; Sorg, R V; Kögler, G; Wernet, P

    2001-08-24

    The regenerative potential of human autologous adult stem cells on myocardial regeneration and neovascularisation after myocardial infarction may contribute to healing of the infarction area. But no clinical application has previously been reported. We here describe for the first time the results of this method applied in a patient who had sustained an acute myocardial infarction. 14 hours after the onset of left precordial pain a 46-year-old man was admitted to our hospital for interventional diagnosis and treatment. Coronary angiography demonstrated occlusion of the anterior descending branch of the left coronary artery with transmural infarction. This was treated by percutaneous transluminal catheter angioplasty and stent placement. Mononuclear bone marrow cells of the patient were prepared and 6 days after infaction 1,2 infinity 107 cells were transplanted at low pressure via a percutaneous transluminal catheter placed in the infarct-related artery. Before and 10 weeks after this procedure left ventricular function, infarct size, ventricular geometry and myocardial perfusion were measured by (201)thallium SPECT both at rest and on exercise, together with bull's-eye analysis, dobutamine stress echocardiography, right heart catheterisation and radionuclide ventriculography. At 10 weeks after the stem cell transplantation the transmural infarct area had been reduced from 24.6 % to 15.7 % of left ventricular circumference, while ejection fraction, cardiac index and stroke volume had increased by 20-30 %. On exercise the end diastolic volume had decreased by 30 % and there was a comparable fall in left ventricular filling pressure (mean pulmonary capillary pressure). These results for the first time demonstrate that selective intracoronary transplantation of human autologous adult stem cells is possible under clinical conditions and that it can lead to regeneration of the myocardial scar after transmural infarction. The therapeutic effects may be ascribed to stem

  14. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies

    PubMed Central

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-01-01

    Objective To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Methods and results Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2  =  0.92 versus r2  =  0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (κ  =  0.87 v κ  =  0.75, p < 0.05). Conclusion MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine. PMID:15939722

  15. Usefulness of myocardial parametric imaging to evaluate myocardial viability in experimental and in clinical studies.

    PubMed

    Korosoglou, G; Hansen, A; Bekeredjian, R; Filusch, A; Hardt, S; Wolf, D; Schellberg, D; Katus, H A; Kuecherer, H

    2006-03-01

    To evaluate whether myocardial parametric imaging (MPI) is superior to visual assessment for the evaluation of myocardial viability. Myocardial contrast echocardiography (MCE) was assessed in 11 pigs before, during, and after left anterior descending coronary artery occlusion and in 32 patients with ischaemic heart disease by using intravenous SonoVue administration. In experimental studies perfusion defect area assessment by MPI was compared with visually guided perfusion defect planimetry. Histological assessment of necrotic tissue was the standard reference. In clinical studies viability was assessed on a segmental level by (1) visual analysis of myocardial opacification; (2) quantitative estimation of myocardial blood flow in regions of interest; and (3) MPI. Functional recovery between three and six months after revascularisation was the standard reference. In experimental studies, compared with visually guided perfusion defect planimetry, planimetric assessment of infarct size by MPI correlated more significantly with histology (r2 = 0.92 versus r2 = 0.56) and had a lower intraobserver variability (4% v 15%, p < 0.05). In clinical studies, MPI had higher specificity (66% v 43%, p < 0.05) than visual MCE and good accuracy (81%) for viability detection. It was less time consuming (3.4 (1.6) v 9.2 (2.4) minutes per image, p < 0.05) than quantitative blood flow estimation by regions of interest and increased the agreement between observers interpreting myocardial perfusion (kappa = 0.87 v kappa = 0.75, p < 0.05). MPI is useful for the evaluation of myocardial viability both in animals and in patients. It is less time consuming than quantification analysis by regions of interest and less observer dependent than visual analysis. Thus, strategies incorporating this technique may be valuable for the evaluation of myocardial viability in clinical routine.

  16. Automatic regional analysis of myocardial native T1 values: left ventricle segmentation and AHA parcellations.

    PubMed

    Huang, Hsiao-Hui; Huang, Chun-Yu; Chen, Chiao-Ning; Wang, Yun-Wen; Huang, Teng-Yi

    2018-01-01

    Native T1 value is emerging as a reliable indicator of abnormal heart conditions related to myocardial fibrosis. Investigators have extensively used the standardized myocardial segmentation of the American Heart Association (AHA) to measure regional T1 values of the left ventricular (LV) walls. In this paper, we present a fully automatic system to analyze modified Look-Locker inversion recovery images and to report regional T1 values of AHA segments. Ten healthy individuals participated in the T1 mapping study with a 3.0 T scanner after providing informed consent. First, we obtained masks of an LV blood-pool region and LV walls by using an image synthesis method and a layer-growing method. Subsequently, the LV walls were divided into AHA segments by identifying the boundaries of the septal regions and by using a radial projection method. The layer-growing method significantly enhanced the accuracy of the derived myocardium mask. We compared the T1 values that were obtained using manual region of interest selections and those obtained using the automatic system. The average T1 difference of the calculated segments was 4.6 ± 1.5%. This study demonstrated a practical and robust method of obtaining native T1 values of AHA segments in LV walls.

  17. Myocardial perfusion imaging: Lessons learned and work to be done-update.

    PubMed

    Iskandrian, Ami E; Dilsizian, Vasken; Garcia, Ernest V; Beanlands, Rob S; Cerqueira, Manuel; Soman, Prem; Berman, Daniel S; Cuocolo, Alberto; Einstein, Andrew J; Morgan, Charity J; Hage, Fadi G; Schelbert, Heinrich R; Bax, Jeroen J; Wu, Joseph C; Shaw, Leslee J; Sadeghi, Mehran M; Tamaki, Nagara; Kaufmann, Philipp A; Gropler, Robert; Dorbala, Sharmila; Van Decker, William

    2018-02-01

    As the second term of our commitment to Journal begins, we, the editors, would like to reflect on a few topics that have relevance today. These include prognostication and paradigm shifts; Serial testing: How to handle data? Is the change in perfusion predictive of outcome and which one? Ischemia-guided therapy: fractional flow reserve vs perfusion vs myocardial blood flow; positron emission tomography (PET) imaging using Rubidium-82 vs N-13 ammonia vs F-18 Flurpiridaz; How to differentiate microvascular disease from 3-vessel disease by PET? The imaging scene outside the United States, what are the differences and similarities? Radiation exposure; Special issues with the new cameras? Is attenuation correction needed? Are there normal databases and are these specific to each camera system? And finally, hybrid imaging with single-photon emission tomography or PET combined with computed tomography angiography or coronary calcium score. We hope these topics are of interest to our readers.

  18. Stress Computed Tomography Myocardial Perfusion Imaging: A New Topic in Cardiology.

    PubMed

    Seitun, Sara; Castiglione Morelli, Margherita; Budaj, Irilda; Boccalini, Sara; Galletto Pregliasco, Athena; Valbusa, Alberto; Cademartiri, Filippo; Ferro, Carlo

    2016-02-01

    Since its introduction about 15 years ago, coronary computed tomography angiography has become today the most accurate clinical instrument for noninvasive assessment of coronary atherosclerosis. Important technical developments have led to a continuous stream of new clinical applications together with a significant reduction in radiation dose exposure. Latest generation computed tomography scanners (≥ 64 slices) allow the possibility of performing static or dynamic perfusion imaging during stress by using coronary vasodilator agents (adenosine, dipyridamole, or regadenoson), combining both functional and anatomical information in the same examination. In this article, the emerging role and state-of-the-art of myocardial computed tomography perfusion imaging are reviewed and are illustrated by clinical cases from our experience with a second-generation dual-source 128-slice scanner (Somatom Definition Flash, Siemens; Erlangen, Germany). Technical aspects, data analysis, diagnostic accuracy, radiation dose and future prospects are reviewed. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  19. 48 CFR 201.201-1 - The two councils.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false The two councils. 201.201-1 Section 201.201-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 201.201-1 The two...

  20. 48 CFR 201.201-1 - The two councils.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false The two councils. 201.201-1 Section 201.201-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 201.201-1 The two...

  1. 48 CFR 201.201-1 - The two councils.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false The two councils. 201.201-1 Section 201.201-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 201.201-1 The two...

  2. 48 CFR 201.201-1 - The two councils.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false The two councils. 201.201-1 Section 201.201-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 201.201-1 The two...

  3. 48 CFR 201.201-1 - The two councils.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false The two councils. 201.201-1 Section 201.201-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 201.201-1 The two...

  4. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    PubMed Central

    McCommis, Kyle S.; Goldstein, Thomas A.; Abendschein, Dana R.; Misselwitz, Bernd; Pilgram, Thomas; Gropler, Robert J.

    2010-01-01

    Objective To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. Methods A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99mTc-labeled red blood cells were injected to obtain respective gold standards. Results Microsphere-measured MBF and 99mTc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. Conclusions MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. PMID:20182731

  5. Underestimation of myocardial blood flow by dynamic perfusion CT: Explanations by two-compartment model analysis and limited temporal sampling of dynamic CT.

    PubMed

    Ishida, Masaki; Kitagawa, Kakuya; Ichihara, Takashi; Natsume, Takahiro; Nakayama, Ryohei; Nagasawa, Naoki; Kubooka, Makiko; Ito, Tatsuro; Uno, Mio; Goto, Yoshitaka; Nagata, Motonori; Sakuma, Hajime

    2016-01-01

    Previous studies using dynamic perfusion CT and volume perfusion CT (VPCT) software consistently underestimated the stress myocardial blood flow (MBF) in normal myocardium to be 1.1-1.4 ml/min/g, whilst the O 15-water PET studies demonstrated the normal stress MBF of 3-5 ml/min/g. We hypothesized that the MBF determined by VPCT (MBF-VPCT) is actually presenting the blood-to-myocardium transfer constant, K1. In this study, we determined K1 using Patlak plot (K1-Patlak) and compared the results with MBF-VPCT. 17 patients (66 ± 9 years, 7 males) with suspected coronary artery disease (CAD) underwent stress dynamic perfusion CT, followed by rest coronary CT angiography (CTA). Arterial input and myocardial output curves were analyzed with Patlak plot to quantify myocardial K1. Significant CAD was defined as >50% stenosis on CTA. A simulation study was also performed to investigate the influence of limited temporal sampling in dynamic CT acquisition on K1 using the undersampling data generated from MRI. There were 3 patients with normal CTA, 7 patients with non-significant CAD, and 7 patients with significant CAD. K1-patlak was 0.98 ± 0.35 (range 0.22-1.67) ml/min/g, whereas MBF-VPCT was 0.83 ± 0.23 (range 0.34-1.40) ml/min/g. There was a linear relationship between them: (MBF-VPCT) = 0.58 x (K1-patlak) + 0.27 (r(2) = 0.65, p < 0.001). The simulation study done on MRI data demonstrated that Patlak plot substantially underestimated true K1 by 41% when true K1 was 2.0 ml/min/g with the temporal sampling of 2RR for arterial input and 4RR for myocardial output functions. The results of our study are generating hypothesis that MBF-VPCT is likely to be calculating K1-patlak equivalent, not MBF. In addition, these values may be substantially underestimated because of limited temporal sampling rate. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  6. Human Umbilical Cord-Derived Mesenchymal Stromal Cells Improve Left Ventricular Function, Perfusion, and Remodeling in a Porcine Model of Chronic Myocardial Ischemia

    PubMed Central

    Liu, Chuan-Bin; Huang, He; Sun, Ping; Ma, Shi-Ze; Liu, An-Heng; Xue, Jian; Fu, Jin-Hui; Liang, Yu-Qian; Liu, Bing; Wu, Dong-Ying

    2016-01-01

    Stem cell therapy has emerged as a new strategy for treatment of ischemic heart disease. Although umbilical cord-derived mesenchymal stromal cells (UC-MSCs) have been used preferentially in the acute ischemia model, data for the chronic ischemia model are lacking. In this study, we investigated the effect of UC-MSCs originated from Wharton’s jelly in the treatment of chronic myocardial ischemia in a porcine model induced by ameroid constrictor. Four weeks after ameroid constrictor placement, the surviving animals were divided randomly into two groups to undergo saline injection (n = 6) or UC-MSC transplantation (n = 6) through the left main coronary artery. Two additional intravenous administrations of UC-MSCs were performed in the following 2 weeks to enhance therapeutic effect. Cardiac function and perfusion were examined just before and at 4 weeks after intracoronary transplantation. The results showed that pigs with UC-MSC transplantation exhibited significantly greater left ventricular ejection fraction compared with control animals (61.3% ± 1.3% vs. 50.3% ± 2.0%, p < .05). The systolic thickening fraction in the infarcted left ventricular wall was also improved (41.2% ± 3.3% vs. 46.2% ± 2.3%, p < .01). Additionally, the administration of UC-MSCs promoted collateral development and myocardial perfusion. The indices of fibrosis and apoptosis were also significantly reduced. Immunofluorescence staining showed clusters of CM-DiI-labeled cells in the border zone, some of which expressed von Willebrand factor. These results suggest that UC-MSC treatment improves left ventricular function, perfusion, and remodeling in a porcine model with chronic myocardial ischemia. Significance Ischemic heart disease is the leading cause of death worldwide. Many patients with chronic myocardial ischemia are not suitable for surgery and have no effective drug treatment; they are called “no-option” patients. This study finds that umbilical cord-derived mesenchymal stromal

  7. Human Umbilical Cord-Derived Mesenchymal Stromal Cells Improve Left Ventricular Function, Perfusion, and Remodeling in a Porcine Model of Chronic Myocardial Ischemia.

    PubMed

    Liu, Chuan-Bin; Huang, He; Sun, Ping; Ma, Shi-Ze; Liu, An-Heng; Xue, Jian; Fu, Jin-Hui; Liang, Yu-Qian; Liu, Bing; Wu, Dong-Ying; Lü, Shuang-Hong; Zhang, Xiao-Zhong

    2016-08-01

    : Stem cell therapy has emerged as a new strategy for treatment of ischemic heart disease. Although umbilical cord-derived mesenchymal stromal cells (UC-MSCs) have been used preferentially in the acute ischemia model, data for the chronic ischemia model are lacking. In this study, we investigated the effect of UC-MSCs originated from Wharton's jelly in the treatment of chronic myocardial ischemia in a porcine model induced by ameroid constrictor. Four weeks after ameroid constrictor placement, the surviving animals were divided randomly into two groups to undergo saline injection (n = 6) or UC-MSC transplantation (n = 6) through the left main coronary artery. Two additional intravenous administrations of UC-MSCs were performed in the following 2 weeks to enhance therapeutic effect. Cardiac function and perfusion were examined just before and at 4 weeks after intracoronary transplantation. The results showed that pigs with UC-MSC transplantation exhibited significantly greater left ventricular ejection fraction compared with control animals (61.3% ± 1.3% vs. 50.3% ± 2.0%, p < .05). The systolic thickening fraction in the infarcted left ventricular wall was also improved (41.2% ± 3.3% vs. 46.2% ± 2.3%, p < .01). Additionally, the administration of UC-MSCs promoted collateral development and myocardial perfusion. The indices of fibrosis and apoptosis were also significantly reduced. Immunofluorescence staining showed clusters of CM-DiI-labeled cells in the border zone, some of which expressed von Willebrand factor. These results suggest that UC-MSC treatment improves left ventricular function, perfusion, and remodeling in a porcine model with chronic myocardial ischemia. Ischemic heart disease is the leading cause of death worldwide. Many patients with chronic myocardial ischemia are not suitable for surgery and have no effective drug treatment; they are called "no-option" patients. This study finds that umbilical cord-derived mesenchymal stromal cells

  8. Noninvasive assessment of T-wave abnormalities on precordial electrocardiograms in middle-aged professional bicyclists

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nishimura, T.; Kambara, H.; Chen, C.H.

    Six middle-aged, active, professional bicyclists with T-wave abnormalities on precordial ECGs were studied noninvasively. Twenty-five aged-matched bicyclists without T-wave abnormalities served as the control subjects. Increased voltage of SV1 + RV5 was demonstrated in all subjects. A 5-year follow-up study revealed that these abnormalities of T-wave inversion became more pronounced with age, except in one case. VCGs showed enlargement of anterior QRS loop and discordant T loop, in all cases. On echocardiography, thickness of both the interventricular septum and the left ventricular posterior wall, and left ventricular mass were significantly increased compared with the control group. 201Tl myocardial scintigraphy atmore » rest and during exercise revealed no regional perfusion defects of the tracer in either case. We conclude that: (1) T-wave abnormalities of precordial ECGs in six middle-aged athletes were progressive in nature; and (2) these electrocardiographic abnormalities seem to be related to left ventricular hypertrophy induced by steady and strenuous training rather than to coronary artery disease.« less

  9. Myocardial perfusion SPECT 2015 in Germany. Results of the 7th survey.

    PubMed

    Lindner, Oliver; Burchert, Wolfgang; Schäfer, Wolfgang; Hacker, Marcus

    2017-02-14

    The working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine presents the results of the 7th survey of myocardial perfusion SPECT (MPS) of the reporting year 2015. 268 questionnaires (173 practices [PR], 67 hospitals [HO], 28 university hospitals [UH]) were evaluated. Results of the last survey from 2012 are set in squared brackets. MPS of 121 939 [105 941] patients were reported. 98 % [95 %] of all MPS were performed with Tc-99m radiopharmaceuticals and 2 % [5 %] with Tl-201. 78 % [79 %] of all patients were studied in PR, 14 % [15 %] in HO, and 8 % [6 %] in UH. A pharmacological stress test was performed in 43 % [39 %] (22 % [24 %] adenosine, 20 % [9 %] regadenoson, 1 % [6 %] dipyridamole or dobutamine). Attenuation correction was applied in 25 % [2009: 10 %] of MPS. Gated SPECT was performed in 78 % [70 %] of all rest MPS, in 80 % [73 %] of all stress and in 76 % [67 %] of all stress and rest MPS. 53 % [33 %] of all nuclear medicine departments performed MPS scoring by default, whereas 24 % [41 %] did not apply any quantification. 31 % [26 %] of all departments noticed an increase in their counted MPS and 29 % [29 %] no changes. Data from 89 departments which participated in all surveys showed an increase in MPS count of 11.1 % (PR: 12.2 %, HO: 4.8 %, UH: 18.4 %). 70 % [60 %] of the MPS were requested by ambulatory care cardiologists. The 2015 MPS survey reveals a high-grade adherence of routine MPS practice to current guidelines. The positive trend in MPS performance and number of MPS already observed in 2012 continues. Educational training remains necessary in the field of SPECT scoring.

  10. Characterization of breast lesion using T1-perfusion magnetic resonance imaging: Qualitative vs. quantitative analysis.

    PubMed

    Thakran, S; Gupta, P K; Kabra, V; Saha, I; Jain, P; Gupta, R K; Singh, A

    2018-06-14

    The objective of this study was to quantify the hemodynamic parameters using first pass analysis of T 1 -perfusion magnetic resonance imaging (MRI) data of human breast and to compare these parameters with the existing tracer kinetic parameters, semi-quantitative and qualitative T 1 -perfusion analysis in terms of lesion characterization. MRI of the breast was performed in 50 women (mean age, 44±11 [SD] years; range: 26-75) years with a total of 15 benign and 35 malignant breast lesions. After pre-processing, T 1 -perfusion MRI data was analyzed using qualitative approach by two radiologists (visual inspection of the kinetic curve into types I, II or III), semi-quantitative (characterization of kinetic curve types using empirical parameters), generalized-tracer-kinetic-model (tracer kinetic parameters) and first pass analysis (hemodynamic-parameters). Chi-squared test, t-test, one-way analysis-of-variance (ANOVA) using Bonferroni post-hoc test and receiver-operating-characteristic (ROC) curve were used for statistical analysis. All quantitative parameters except leakage volume (Ve), qualitative (type-I and III) and semi-quantitative curves (type-I and III) provided significant differences (P<0.05) between benign and malignant lesions. Kinetic parameters, particularly volume transfer coefficient (K trans ) provided a significant difference (P<0.05) between all grades except grade-II vs III. The hemodynamic parameter (relative-leakage-corrected-breast-blood-volume [rBBVcorr) provided a statistically significant difference (P<0.05) between all grades. It also provided highest sensitivity and specificity among all parameters in differentiation between different grades of malignant breast lesions. Quantitative parameters, particularly rBBVcorr and K trans provided similar sensitivity and specificity in differentiating benign from malignant breast lesions for this cohort. Moreover, rBBVcorr provided better differentiation between different grades of malignant breast

  11. Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging.

    PubMed

    Lauzier, Pascal Theriault; Tang, Jie; Speidel, Michael A; Chen, Guang-Hong

    2012-07-01

    To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Images reconstructed using FBP showed a highly nonuniform spatial distribution of noise. This spatial

  12. Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lauzier, Pascal Theriault; Tang Jie; Speidel, Michael A.

    Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise andmore » streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial

  13. Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging

    PubMed Central

    Lauzier, Pascal Thériault; Tang, Jie; Speidel, Michael A.; Chen, Guang-Hong

    2012-01-01

    Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution

  14. [Anomalous origin of the left coronary artery from the pulmonary trunk with myocardial infarction and severe left ventricular dysfunction in infancy--assessment of myocardial damage using SPECT studies with 201TlCl and 123I-BMIPP].

    PubMed

    Miyamoto, T; Horigome, H; Sato, H; Yamada, M; Inai, K; Takeda, T; Ishikawa, N; Hoshino, H; Itai, Y

    1996-02-01

    A 4-month-old male infant with Bland-White-Garland (BWG) syndrome complicated myocardial infarction was reported. Signs included tachypnea, coughing, and failure to thrive. However, there was no sign of myocardial infarction. A chest radiograph revealed cardiomegaly (CTR = 65%) and electrocardiogram showed abnormal Q waves in I, aVL, V6 leads. Cardiac catheterization and angiography revealed marked dilatation of left ventricle (end-diastolic volume = 384 ml/m2) and extremely depressed ejection fraction (16%), confirming the diagnosis of BWG syndrome. A 201TlCl-myocardial SPECT demonstrated apical defect and hypoperfusion in the anterolateral, inferoposterior walls, whereas 123I-beta-methyl-p-iodophenylpentadecanoic-acid (123I-BMIPP) SPECT showed a wider defect area. SPECT studies with 201TlCl and 123I-BMIPP, are useful to assess myocardial viability more accurately in BWG syndrome.

  15. Feasibility of high-resolution quantitative perfusion analysis in patients with heart failure.

    PubMed

    Sammut, Eva; Zarinabad, Niloufar; Wesolowski, Roman; Morton, Geraint; Chen, Zhong; Sohal, Manav; Carr-White, Gerry; Razavi, Reza; Chiribiri, Amedeo

    2015-02-12

    Cardiac magnetic resonance (CMR) is playing an expanding role in the assessment of patients with heart failure (HF). The assessment of myocardial perfusion status in HF can be challenging due to left ventricular (LV) remodelling and wall thinning, coexistent scar and respiratory artefacts. The aim of this study was to assess the feasibility of quantitative CMR myocardial perfusion analysis in patients with HF. A group of 58 patients with heart failure (HF; left ventricular ejection fraction, LVEF ≤ 50%) and 33 patients with normal LVEF (LVEF >50%), referred for suspected coronary artery disease, were studied. All subjects underwent quantitative first-pass stress perfusion imaging using adenosine according to standard acquisition protocols. The feasibility of quantitative perfusion analysis was then assessed using high-resolution, 3 T kt perfusion and voxel-wise Fermi deconvolution. 30/58 (52%) subjects in the HF group had underlying ischaemic aetiology. Perfusion abnormalities were seen amongst patients with ischaemic HF and patients with normal LV function. No regional perfusion defect was observed in the non-ischaemic HF group. Good agreement was found between visual and quantitative analysis across all groups. Absolute stress perfusion rate, myocardial perfusion reserve (MPR) and endocardial-epicardial MPR ratio identified areas with abnormal perfusion in the ischaemic HF group (p = 0.02; p = 0.04; p = 0.02, respectively). In the Normal LV group, MPR and endocardial-epicardial MPR ratio were able to distinguish between normal and abnormal segments (p = 0.04; p = 0.02 respectively). No significant differences of absolute stress perfusion rate or MPR were observed comparing visually normal segments amongst groups. Our results demonstrate the feasibility of high-resolution voxel-wise perfusion assessment in patients with HF.

  16. Sulfamethoxazole Induces a Switch Mechanism in T Cell Receptors Containing TCRVβ20-1, Altering pHLA Recognition

    PubMed Central

    Watkins, Stephan; Pichler, Werner J.

    2013-01-01

    T cell receptors (TCR) containing Vβ20-1 have been implicated in a wide range of T cell mediated disease and allergic reactions, making it a target for understanding these. Mechanics of T cell receptors are largely unexplained by static structures available from x-ray crystallographic studies. A small number of molecular dynamic simulations have been conducted on TCR, however are currently lacking either portions of the receptor or explanations for differences between binding and non-binding TCR recognition of respective peptide-HLA. We performed molecular dynamic simulations of a TCR containing variable domain Vβ20-1, sequenced from drug responsive T cells. These were initially from a patient showing maculopapular eruptions in response to the sulfanilamide-antibiotic sulfamethoxazole (SMX). The CDR2β domain of this TCR was found to dock SMX with high affinity. Using this compound as a perturbation, overall mechanisms involved in responses mediated by this receptor were explored, showing a chemical action on the TCR free from HLA or peptide interaction. Our simulations show two completely separate modes of binding cognate peptide-HLA complexes, with an increased affinity induced by SMX bound to the Vβ20-1. Overall binding of the TCR is mediated through a primary recognition by either the variable β or α domain, and a switch in recognition within these across TCR loops contacting the peptide and HLA occurs when SMX is present in the CDR2β loop. Large binding affinity differences are induced by summed small amino acid changes primarily by SMX modifying only three critical CDR2β loop amino acid positions. These residues, TYRβ57, ASPβ64, and LYSβ65 initially hold hydrogen bonds from the CDR2β to adjacent CDR loops. Effects from SMX binding are amplified and traverse longer distances through internal TCR hydrogen bonding networks, controlling the overall TCR conformation. Thus, the CDR2β of Vβ20-1 acts as a ligand controlled switch affecting overall TCR

  17. Comparison of the sensitivity and specificity of 5 image sets of dual-energy computed tomography for detecting first-pass myocardial perfusion defects compared with positron emission tomography.

    PubMed

    Li, Wenhuan; Zhu, Xiaolian; Li, Jing; Peng, Cheng; Chen, Nan; Qi, Zhigang; Yang, Qi; Gao, Yan; Zhao, Yang; Sun, Kai; Li, Kuncheng

    2014-12-01

    The sensitivity and specificity of 5 different image sets of dual-energy computed tomography (DECT) for the detection of first-pass myocardial perfusion defects have not systematically been compared using positron emission tomography (PET) as a reference standard. Forty-nine consecutive patients, with known or strongly suspected of coronary artery disease, were prospectively enrolled in our study. Cardiac DECT was performed at rest state using a second-generation 128-slice dual-source CT. The DECT data were reconstructed to iodine maps, monoenergetic images, 100 kV images, nonlinearly blended images, and linearly blended images by different postprocessing techniques. The myocardial perfusion defects on DECT images were visually assessed by 5 observers, using standard 17-segment model. Diagnostic accuracy of 5 image sets was assessed using nitrogen-13 ammonia PET as the gold standard. Discrimination was quantified using the area under the receiver operating characteristic curve (AUC), and AUCs were compared using the method of DeLong. The DECT and PET examinations were successfully completed in 30 patients and a total of 90 territories and 510 segments were analyzed. Cardiac PET revealed myocardial perfusion defects in 56 territories (62%) and 209 segments (41%). The AUC of iodine maps, monoenergetic images, 100 kV images, nonlinearly blended images, and linearly blended images were 0.986, 0.934, 0.913, 0.881, and 0.871, respectively, on a per-territory basis. These values were 0.922, 0.813, 0.779, 0.763, and 0.728, respectively, on a per-segment basis. DECT iodine maps shows high sensitivity and specificity, and is superior to other DECT image sets for the detection of myocardial perfusion defects in the first-pass myocardial perfusion.

  18. Intracoronary Administration of Allogeneic Adipose Tissue-Derived Mesenchymal Stem Cells Improves Myocardial Perfusion But Not Left Ventricle Function, in a Translational Model of Acute Myocardial Infarction.

    PubMed

    Bobi, Joaquim; Solanes, Núria; Fernández-Jiménez, Rodrigo; Galán-Arriola, Carlos; Dantas, Ana Paula; Fernández-Friera, Leticia; Gálvez-Montón, Carolina; Rigol-Monzó, Elisabet; Agüero, Jaume; Ramírez, José; Roqué, Mercè; Bayés-Genís, Antoni; Sánchez-González, Javier; García-Álvarez, Ana; Sabaté, Manel; Roura, Santiago; Ibáñez, Borja; Rigol, Montserrat

    2017-05-03

    Autologous adipose tissue-derived mesenchymal stem cells (ATMSCs) therapy is a promising strategy to improve post-myocardial infarction outcomes. In a porcine model of acute myocardial infarction, we studied the long-term effects and the mechanisms involved in allogeneic ATMSCs administration on myocardial performance. Thirty-eight pigs underwent 50 minutes of coronary occlusion; the study was completed in 33 pigs. After reperfusion, allogeneic ATMSCs or culture medium (vehicle) were intracoronarily administered. Follow-ups were performed at short (2 days after acute myocardial infarction vehicle-treated, n=10; ATMSCs-treated, n=9) or long term (60 days after acute myocardial infarction vehicle-treated, n=7; ATMSCs-treated, n=7). At short term, infarcted myocardium analysis showed reduced apoptosis in the ATMSCs-treated animals (48.6±6% versus 55.9±5.7% in vehicle; P =0.017); enhancement of the reparative process with up-regulated vascular endothelial growth factor, granulocyte macrophage colony-stimulating factor, and stromal-derived factor-1α gene expression; and increased M2 macrophages (67.2±10% versus 54.7±10.2% in vehicle; P =0.016). In long-term groups, increase in myocardial perfusion at the anterior infarct border was observed both on day-7 and day-60 cardiac magnetic resonance studies in ATMSCs-treated animals, compared to vehicle (87.9±28.7 versus 57.4±17.7 mL/min per gram at 7 days; P =0.034 and 99±22.6 versus 43.3±14.7 22.6 mL/min per gram at 60 days; P =0.0001, respectively). At day 60, higher vascular density was detected at the border zone in the ATMSCs-treated animals (118±18 versus 92.4±24.3 vessels/mm 2 in vehicle; P =0.045). Cardiac magnetic resonance-measured left ventricular ejection fraction of left ventricular volumes was not different between groups at any time point. In this porcine acute myocardial infarction model, allogeneic ATMSCs-based therapy was associated with increased cardioprotective and reparative

  19. Discordance Between Appropriate Use Criteria for Nuclear Myocardial Perfusion Imaging From Different Specialty Societies: A Potential Concern for Health Policy.

    PubMed

    Winchester, David E; Wolinsky, David; Beyth, Rebecca J; Shaw, Leslee J

    2016-05-01

    Appropriate use criteria (AUC) assist health care professionals in making decisions about procedures and diagnostic testing. In some cases, multiple AUC exist for a single procedure or test. To date, the extent of agreement between multiple AUC has not been evaluated. To measure discordance between the American College of Cardiology Foundation (ACCF) AUC and the American College of Radiology (ACR) Appropriateness Criteria for gauging the appropriateness of nuclear myocardial perfusion imaging. Retrospective cohort study at an academically affiliated Veterans Affairs medical center. Participants were Veteran patients who underwent nuclear myocardial perfusion imaging between December 2010 and July 2011 with rating of appropriateness by the ACCF and ACR criteria. Analysis was performed in March 2015. The primary outcome was the agreement of appropriateness category as measured by κ statistic. The secondary outcome was a comparison of nuclear myocardial perfusion imaging results and frequency of ischemia across appropriateness categories for the 2 rating methods. Of 67 indications in the ACCF AUC, 35 (52.2%) could not be matched to an ACR rating, 18 (26.9%) had the same appropriateness category, and 14 (20.9%) disagreed on appropriateness. The study cohort comprised 592 individuals. Their mean (SD) age was 62.6 (9.4) years, and 570 of 592 (96.2%) were male. When applied to the patient cohort, 111 patients (18.8%) could not be matched to an ACR rating, 349 patients (59.0%) had the same appropriateness category for the ACR and ACCF methods, and 132 patients (22.3%) were discordant. Overall, the agreement of appropriateness between the 2 methods was poor (κ = 0.34, P < .001). Ischemia was rare among patients rated as "inappropriate" by the ACCF AUC (1 of 39 patients [2.6%]), while ischemia was more common among patients rated as "usually not appropriate" by the ACR Appropriateness Criteria (14 of 80 patients [17.5%]). Substantial discordance may exist between

  20. Use of myocardial perfusion imaging and estimation of associated radiation doses in Germany from 2005 to 2012.

    PubMed

    Lindner, O; Bengel, F M; Hacker, M; Schäfer, W; Burchert, W

    2014-05-01

    For several years the Working Group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine has been performing a regular survey to obtain information on technique, utilization and development of myocardial perfusion scintigraphy (MPS). Currently, data of six surveys from 2005 to 2012 are available. The aim of this paper is to deliver a general and comprehensive overview of all surveys documenting the course of patient doses over time and the development of the method. A one-page questionnaire with number of MPS patients, number of stress and rest MPS, referral structure and several technical issues was sent to all centres performing MPS in Germany and evaluated. With the data on protocol utilization, effective MPS patient doses were estimated. MPS per million population (pmp) varied between 2,380 and 2,770. In 2012, MPS pmp showed a slight increase for the first time. From 2005 to 2009 the angiography to MPS ratio increased from 3.4 to 4.4, and the revascularization to MPS ratio decreased from 0.66 to 0.53. In 2012, both indices demonstrated an opposite trend for the first time (4.1 and 0.55). A total of 108 centres participated in all surveys. They showed an increase in MPS patients of 4.0 % over the reporting period. In 2012, more than 50 % of the centres experienced no change or an increase in MPS numbers. The leading single competitor was MRI, followed by angiography and stress echocardiography. (201)Tl studies have decreased since 2005 from 20 to 5 %. (99m)Tc MPS studies showed a mild increase in 2-day protocols. In 2012, the average effective dose per patient was estimated at 7.4 mSv. Due to the decreasing use of (201)Tl, a mild decline over the observation period can be documented. Dynamic exercise stress was the most common stress test and adenosine the leading pharmacological stress agent, with a growing percentage. In 2012, the regadenoson percentage was 9 %. Gated single photon emission computed tomography (SPECT) noted an increasing

  1. Dynamic iterative beam hardening correction (DIBHC) in myocardial perfusion imaging using contrast-enhanced computed tomography.

    PubMed

    Stenner, Philip; Schmidt, Bernhard; Allmendinger, Thomas; Flohr, Thomas; Kachelrie, Marc

    2010-06-01

    only 1 HU for the simulations and the corrected values show an increase of up to 61 HU for the measurements. One iteration of DIBHC greatly reduces the beam hardening artifacts induced by the contrast agent dynamics (and those due to bone) now allowing for an improved assessment of contrast agent uptake in the myocardium which is essential for determining myocardial perfusion.

  2. Association between aortic valve calcification and myocardial ischemia, especially in asymptomatic patients.

    PubMed

    Yamazato, Ryo; Yamamoto, Hideya; Tadehara, Futoshi; Teragawa, Hiroki; Kurisu, Satoshi; Dohi, Yoshihiro; Ishibashi, Ken; Kunita, Eiji; Utsunomiya, Hiroto; Oka, Toshiharu; Kihara, Yasuki

    2012-08-01

    Aortic valve calcification (AVC) is recognized as a manifestation of systemic arteriosclerosis. However, it is unclear whether AVC is associated with myocardial ischemia. Stress myocardial perfusion SPECT (MPS) is widely used for the diagnosis of myocardial ischemia. However, routine MPS is not recommended, particularly in asymptomatic patients. Accordingly, we investigated the hypothesis that the presence of AVC is strongly associated with inducible myocardial ischemia, even among asymptomatic patients. We investigated 669 consecutive patients who underwent both adenosine stress (201)Tl MPS and echocardiography. We evaluated the extent and severity of myocardial ischemia by the summed difference score (SDS). We defined the presence of myocardial ischemia as SDS ≥ 3 and moderate to severe ischemia as SDS ≥ 8. We classified the severity of AVC according to the number of affected aortic leaflets. We also compared the mean SDS and the prevalence of SDS ≥ 3 and SDS ≥ 8 among patients stratified by the severity of AVC. The presence of AVC was significantly associated with myocardial ischemia (odds ratio [OR], 1.56; 95% confidence interval [CI], 1.10-2.23; P = 0.013) and moderate to severe ischemia (OR, 2.16; 95% CI, 1.26-3.80; P = 0.0061). In 311 asymptomatic patients, AVC was strongly associated with moderate to severe ischemia (OR, 4.31; 95% CI, 1.67-12.8; P = 0.0043). However, the SDS value and the prevalence of SDS ≥ 3 and SDS ≥ 8 did not increase with increasing number of affected aortic leaflets. The presence of AVC may be associated with the presence of myocardial ischemia, particularly in asymptomatic patients. However, we found no association between the extent of AVC and inducible myocardial ischemia. The presence of AVC may be a useful anatomic marker to help identify patients at high risk of myocardial ischemia, particularly asymptomatic patients.

  3. Multicenter Evaluation of a 0-Hour/1-Hour Algorithm in the Diagnosis of Myocardial Infarction With High-Sensitivity Cardiac Troponin T.

    PubMed

    Mueller, Christian; Giannitsis, Evangelos; Christ, Michael; Ordóñez-Llanos, Jorge; deFilippi, Christopher; McCord, James; Body, Richard; Panteghini, Mauro; Jernberg, Tomas; Plebani, Mario; Verschuren, Franck; French, John; Christenson, Robert; Weiser, Silvia; Bendig, Garnet; Dilba, Peter; Lindahl, Bertil

    2016-07-01

    We aim to prospectively validate the diagnostic accuracy of the recently developed 0-h/1-h algorithm, using high-sensitivity cardiac troponin T (hs-cTnT) for the early rule-out and rule-in of acute myocardial infarction. We enrolled patients presenting with suspected acute myocardial infarction and recent (<6 hours) onset of symptoms to the emergency department in a global multicenter diagnostic study. Hs-cTnT (Roche Diagnostics) and sensitive cardiac troponin I (Siemens Healthcare) were measured at presentation and after 1 hour, 2 hours, and 4 to 14 hours in a central laboratory. Patient triage according to the predefined hs-cTnT 0-hour/1-hour algorithm (hs-cTnT below 12 ng/L and Δ1 hour below 3 ng/L to rule out; hs-cTnT at least 52 ng/L or Δ1 hour at least 5 ng/L to rule in; remaining patients to the "observational zone") was compared against a centrally adjudicated final diagnosis by 2 independent cardiologists (reference standard). The final diagnosis was based on all available information, including coronary angiography and echocardiography results, follow-up data, and serial measurements of sensitive cardiac troponin I, whereas adjudicators remained blinded to hs-cTnT. Among 1,282 patients enrolled, acute myocardial infarction was the final diagnosis for 213 (16.6%) patients. Applying the hs-cTnT 0-hour/1-hour algorithm, 813 (63.4%) patients were classified as rule out, 184 (14.4%) were classified as rule in, and 285 (22.2%) were triaged to the observational zone. This resulted in a negative predictive value and sensitivity for acute myocardial infarction of 99.1% (95% confidence interval [CI] 98.2% to 99.7%) and 96.7% (95% CI 93.4% to 98.7%) in the rule-out zone (7 patients with false-negative results), a positive predictive value and specificity for acute myocardial infarction of 77.2% (95% CI 70.4% to 83.0%) and 96.1% (95% CI 94.7% to 97.2%) in the rule-in zone, and a prevalence of acute myocardial infarction of 22.5% in the observational zone. The hs-cTnT

  4. Myocardial T1 mapping at 3.0 tesla using an inversion recovery spoiled gradient echo readout and bloch equation simulation with slice profile correction (BLESSPC) T1 estimation algorithm.

    PubMed

    Shao, Jiaxin; Rapacchi, Stanislas; Nguyen, Kim-Lien; Hu, Peng

    2016-02-01

    To develop an accurate and precise myocardial T1 mapping technique using an inversion recovery spoiled gradient echo readout at 3.0 Tesla (T). The modified Look-Locker inversion-recovery (MOLLI) sequence was modified to use fast low angle shot (FLASH) readout, incorporating a BLESSPC (Bloch Equation Simulation with Slice Profile Correction) T1 estimation algorithm, for accurate myocardial T1 mapping. The FLASH-MOLLI with BLESSPC fitting was compared with different approaches and sequences with regards to T1 estimation accuracy, precision and image artifact based on simulation, phantom studies, and in vivo studies of 10 healthy volunteers and three patients at 3.0 Tesla. The FLASH-MOLLI with BLESSPC fitting yields accurate T1 estimation (average error = -5.4 ± 15.1 ms, percentage error = -0.5% ± 1.2%) for T1 from 236-1852 ms and heart rate from 40-100 bpm in phantom studies. The FLASH-MOLLI sequence prevented off-resonance artifacts in all 10 healthy volunteers at 3.0T. In vivo, there was no significant difference between FLASH-MOLLI-derived myocardial T1 values and "ShMOLLI+IE" derived values (1458.9 ± 20.9 ms versus 1464.1 ± 6.8 ms, P = 0.50); However, the average precision by FLASH-MOLLI was significantly better than that generated by "ShMOLLI+IE" (1.84 ± 0.36% variance versus 3.57 ± 0.94%, P < 0.001). The FLASH-MOLLI with BLESSPC fitting yields accurate and precise T1 estimation, and eliminates banding artifacts associated with bSSFP at 3.0T. © 2015 Wiley Periodicals, Inc.

  5. Direct Quantification of Post-Stress-Rest Left Ventricular Motion and Thickening Changes for Myocardial Perfusion SPECT

    PubMed Central

    Karimi-Ashtiani, Shahryar; Arsanjani, Reza; Fish, Mathews; Kavanagh, Paul; Germano, Guido; Berman, Daniel; Slomka, Piotr

    2012-01-01

    Changes in myocardial wall motion and thickening during myocardial perfusion single-photon emission computed tomography (MPS) are typically assessed separately from gated studies to assess for stress induced functional abnormalities. We sought to develop and validate a novel approach for automatic quantification of post-stress-rest myocardial motion and thickening changes (MTC). Methods Endocardial surfaces at the end-diastolic and end-systolic frames for post-stress and rest studies were registered automatically to each other by matching ventricular surfaces. Myocardial MTCs were computed and normal limits of change were determined as the mean and standard deviation for each polar sample. Normal limits were utilized to quantify the MTCs for each map and the accumulated sample values were used for abnormality assessments in segmental regions. A hybrid method was devised by combining the Total Perfusion Deficit (TPD) and MTC for each vessel territory. Normal limits were obtained from 100 subjects with low likelihood (LLK) of coronary artery disease (CAD). For validation, 623 subjects with correlating invasive angiography were studied. All subjects had a stress/rest 99mTc-sestamibi exercise or adenosine test, and all had coronary angiography within 3 months of MPS. All MTC and TPD measurements were derived automatically. The diagnostic accuracy for detection of coronary artery disease for MTC+TPD was compared to TPD alone. Results Segmental normal values for motion change were between −1.3 and −4.1 mm and between −30.1% and −9.8% for thickening change. MTC combined with TPD achieved 61% sensitivity for 3-vessel disease (3VD), 63% for 2-vessel disease (2VD), and 90% for 1-vessel disease (1VD) detection vs. 32% for 3VD (P <0.0001), 53% for 2VD (P < 0.001), and 90% for 1VD (P = 1.0) detection with TPD alone method. The specificity for the combined method was 71% for 3VD, 72% for 2VD, and 47% for 1 VD detection vs. 90% for 3VD (P < 0.0001), 80% for 2VD (P <0

  6. Design of a digital phantom population for myocardial perfusion SPECT imaging research.

    PubMed

    Ghaly, Michael; Du, Yong; Fung, George S K; Tsui, Benjamin M W; Links, Jonathan M; Frey, Eric

    2014-06-21

    Digital phantoms and Monte Carlo (MC) simulations have become important tools for optimizing and evaluating instrumentation, acquisition and processing methods for myocardial perfusion SPECT (MPS). In this work, we designed a new adult digital phantom population and generated corresponding Tc-99m and Tl-201 projections for use in MPS research. The population is based on the three-dimensional XCAT phantom with organ parameters sampled from the Emory PET Torso Model Database. Phantoms included three variations each in body size, heart size, and subcutaneous adipose tissue level, for a total of 27 phantoms of each gender. The SimSET MC code and angular response functions were used to model interactions in the body and the collimator-detector system, respectively. We divided each phantom into seven organs, each simulated separately, allowing use of post-simulation summing to efficiently model uptake variations. Also, we adapted and used a criterion based on the relative Poisson effective count level to determine the required number of simulated photons for each simulated organ. This technique provided a quantitative estimate of the true noise in the simulated projection data, including residual MC simulation noise. Projections were generated in 1 keV wide energy windows from 48-184 keV assuming perfect energy resolution to permit study of the effects of window width, energy resolution, and crosstalk in the context of dual isotope MPS. We have developed a comprehensive method for efficiently simulating realistic projections for a realistic population of phantoms in the context of MPS imaging. The new phantom population and realistic database of simulated projections will be useful in performing mathematical and human observer studies to evaluate various acquisition and processing methods such as optimizing the energy window width, investigating the effect of energy resolution on image quality and evaluating compensation methods for degrading factors such as crosstalk

  7. Prognostic significance of normal quantitative Tl-201 stress scintigraphy in relation to pretest likelihood of coronary artery disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russo, D.J.; Russo, D.; Clements, J.

    A previous study reported an excellent prognosis and low cardiac event rate in patients(pts) with chest pain and normal quantitative T1-201 scintigraphy(SC). Such result would not be unexpected if the population under study had a predominance of pts with low pre-T1-201 likelihood(L) of significant coronary artery disease (CAD). Hence, the authors undertook telephone follow-up in pts with chest pain syndrome and normal quantitative T1-201 exercise SC, and related outcome to pretest L of CAD. Pretest L was determined by serial L analysis on the basis of: symptoms, age, sex, and exercise ECG. All pts had T1-201 SC immediately post exercisemore » and 2 hrs later. After interpolative background correction, circumferential count and washout profiles were generated. All pts had unequivocally normal studies. Of a total of 96 pts studied in 1981-82, 20 pts were lost to follow-up. Of the remaining 76 pts, 45 were males and 31 females. The pretest L of CAD had an inverted Gaussian distribution: thirty-four pts(47%) had <33% L of CAD, 3 pts (5%) had 33-66% L of CAD, and 35 pts(48%) had >66% L of CAD. Mean follow-up was 22+- 3 months. No deaths occurred. Two pts(3%) (with pretest L of 54% and 94%) had myocardial infarctions, 8 and 22 months respectively after T1-201 stress SC. One pt underwent percutaneous transluminal coronary angioplasty (PTCA) 16 months after T1-201 stress SC. These findings confirm excellent prognostic significance of normal quantitative T1-201 stress scintigraphy.« less

  8. Efficacy of full-fat milk and diluted lemon juice in reducing infra-cardiac activity of (99m)Tc sestamibi during myocardial perfusion imaging.

    PubMed

    Purbhoo, Khushica; Vangu, Mboyo Di Tamba Willy

    2015-01-01

    When using (99m)Tc sestamibi for myocardial perfusion imaging, increased splanchnic activity creates a problem in the visual and quantitative interpretation of the inferior and infero-septal walls of the left ventricle. We sought to determine whether the administration of diluted lemon juice or full-fat milk would be effective in reducing interfering infra-cardiac activity and therefore result in an improvement in image quality. We compared the administration of full-fat milk and diluted lemon juice to a control group that had no intervention. The study was carried out prospectively. All patients referred to our institution for myocardial perfusion imaging from November 2009 to May 2012 were invited to be enrolled in the study. A total of 630 patients were randomised into three groups. Group 0 (G0), 246 patients, were given diluted lemon juice, group 1 (G1), 313 patients, were given full-fat milk, and group 2 (G2), 71 patients, had no intervention (control group). A routine two-day protocol was used and the patients were given the same intervention on both days. Raw data of both the stress and rest images were visually assessed for the presence of infra-cardiac activity, and quantitative grading of the relative intensity of myocardial activity to infra-cardiac activity was determined. The physicians were blinded to the intervention received and the data were reviewed simultaneously. The overall incidence of interfering infra-cardiac activity at stress was 84.1, 84.5 and 96.6% in G0, G1 and G2, respectively (p = 0.005). At rest it was 91.7, 90.1 and 100% in G0, G1 and G2, respectively (p = 0.0063). The visual and quantitative results favoured both milk and lemon juice in reducing the amount of interfering infra-cardiac activity versus no intervention. The administration of milk or lemon juice resulted in a significant decrease in the intensity of infra-cardiac activity compared to the control group. This reduction in intensity was even more significant in the milk

  9. Comparison of myocardial perfusion imaging between the new high-speed gamma camera and the standard anger camera.

    PubMed

    Tanaka, Hirokazu; Chikamori, Taishiro; Hida, Satoshi; Uchida, Kenji; Igarashi, Yuko; Yokoyama, Tsuyoshi; Takahashi, Masaki; Shiba, Chie; Yoshimura, Mana; Tokuuye, Koichi; Yamashina, Akira

    2013-01-01

    Cadmium-zinc-telluride (CZT) solid-state detectors have been recently introduced into the field of myocardial perfusion imaging. The aim of this study was to prospectively compare the diagnostic performance of the CZT high-speed gamma camera (Discovery NM 530c) with that of the standard 3-head gamma camera in the same group of patients. The study group consisted of 150 consecutive patients who underwent a 1-day stress-rest (99m)Tc-sestamibi or tetrofosmin imaging protocol. Image acquisition was performed first on a standard gamma camera with a 15-min scan time each for stress and for rest. All scans were immediately repeated on a CZT camera with a 5-min scan time for stress and a 3-min scan time for rest, using list mode. The correlations between the CZT camera and the standard camera for perfusion and function analyses were strong within narrow Bland-Altman limits of agreement. Using list mode analysis, image quality for stress was rated as good or excellent in 97% of the 3-min scans, and in 100% of the ≥4-min scans. For CZT scans at rest, similarly, image quality was rated as good or excellent in 94% of the 1-min scans, and in 100% of the ≥2-min scans. The novel CZT camera provides excellent image quality, which is equivalent to standard myocardial single-photon emission computed tomography, despite a short scan time of less than half of the standard time.

  10. All-Systolic Non-ECG-gated Myocardial Perfusion MRI: Feasibility of Multi-Slice Continuous First-Pass Imaging

    PubMed Central

    Sharif, Behzad; Arsanjani, Reza; Dharmakumar, Rohan; Bairey Merz, C. Noel; Berman, Daniel S.; Li, Debiao

    2015-01-01

    Purpose To develop and test the feasibility of a new method for non-ECG-gated first-pass perfusion (FPP) cardiac MR capable of imaging multiple short-axis slices at the same systolic cardiac phase. Methods A magnetization-driven pulse sequence was developed for non-ECG-gated FPP imaging without saturation-recovery preparation using continuous slice-interleaved radial sampling. The image reconstruction method, dubbed TRACE, employed self-gating based on reconstruction of a real-time image-based navigator combined with reference-constrained compressed sensing. Data from ischemic animal studies (n=5) was used in a simulation framework to evaluate temporal fidelity. Healthy subjects (n=5) were studied using both the proposed and conventional method to compare the myocardial contrast-to-noise ratio (CNR). Patients (n=2) underwent adenosine stress studies using the proposed method. Results Temporal fidelity of the developed method was shown to be sufficient at high heart-rates. The healthy volunteers studies demonstrated normal perfusion and no artifacts. Compared to the conventional scheme, myocardial CNR for the proposed method was slightly higher (8.6±0.6 vs. 8.0±0.7). Patient studies showed stress-induced perfusion defects consistent with invasive angiography. Conclusions The presented methods and results demonstrate feasibility of the proposed approach for high-resolution non-ECG-gated FPP imaging and indicate its potential for achieving desirable image quality (high CNR, no dark-rim artifacts) with a 3-slice spatial coverage, all imaged at the same systolic phase. PMID:26052843

  11. Right ventricle performances with echocardiography and 99mTc myocardial perfusion imaging in pulmonary arterial hypertension patients.

    PubMed

    Liu, Jie; Fei, Lei; Huang, Guang-Qing; Shang, Xiao-Ke; Liu, Mei; Pei, Zhi-Jun; Zhang, Yong-Xue

    2018-05-01

    Right heart catheterization is commonly used to measure right ventricle hemodynamic parameters and is the gold standard for pulmonary arterial hypertension diagnosis; however, it is not suitable for patients' long-term follow-up. Non-invasive echocardiography and nuclear medicine have been applied to measure right ventricle anatomy and function, but the guidelines for the usefulness of clinical parameters remain to be established. The goal of this study is to identify reliable clinical parameters of right ventricle function in pulmonary arterial hypertension patients and analyze the relationship of these clinical parameters with the disease severity of pulmonary arterial hypertension. In this study, 23 normal subjects and 23 pulmonary arterial hypertension patients were recruited from January 2015 to March 2016. Pulmonary arterial hypertension patients were classified into moderate and severe pulmonary arterial hypertension groups according to their mean pulmonary arterial pressure levels. All the subjects were subjected to physical examination, chest X-ray, 12-lead electrocardiogram, right heart catheterization, two-dimensional echocardiography, and technetium 99m ( 99m Tc) myocardial perfusion imaging. Compared to normal subjects, the right heart catheterization indexes including right ventricle systolic pressure, right ventricle end diastolic pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, pulmonary vascular resistance, and right ventricle end systolic pressure increased in pulmonary arterial hypertension patients and were correlated with mean pulmonary arterial pressure levels. Echocardiography parameters, including tricuspid regurgitation peak velocity, tricuspid regurgitation pressure gradient, tricuspid annular plane systolic excursion and fractional area, right ventricle-myocardial performance index, were significantly associated with the mean pulmonary arterial pressure levels in pulmonary arterial hypertension patients

  12. A Generator-Produced Gallium-68 Radiopharmaceutical for PET Imaging of Myocardial Perfusion

    PubMed Central

    Sharma, Vijay; Sivapackiam, Jothilingam; Harpstrite, Scott E.; Prior, Julie L.; Gu, Hannah; Rath, Nigam P.; Piwnica-Worms, David

    2014-01-01

    Lipophilic cationic technetium-99m-complexes are widely used for myocardial perfusion imaging (MPI). However, inherent uncertainties in the supply chain of molybdenum-99, the parent isotope required for manufacturing 99Mo/99mTc generators, intensifies the need for discovery of novel MPI agents incorporating alternative radionuclides. Recently, germanium/gallium (Ge/Ga) generators capable of producing high quality 68Ga, an isotope with excellent emission characteristics for clinical PET imaging, have emerged. Herein, we report a novel 68Ga-complex identified through mechanism-based cell screening that holds promise as a generator-produced radiopharmaceutical for PET MPI. PMID:25353349

  13. Early myocardial damage assessment in dystrophinopathies using (99)Tc(m)-MIBI gated myocardial perfusion imaging.

    PubMed

    Zhang, Li; Liu, Zhe; Hu, Ke-You; Tian, Qing-Bao; Wei, Ling-Ge; Zhao, Zhe; Shen, Hong-Rui; Hu, Jing

    2015-01-01

    Early detection of muscular dystrophy (MD)-associated cardiomyopathy is important because early medical treatment may slow cardiac remodeling and attenuate symptoms of cardiac dysfunction; however, no sensitive and standard diagnostic method for MD at an earlier stage has been well-recognized. Thus, the aim of this study was to test the early diagnostic value of technetium 99m-methoxyisobutylisonitrile ((99)Tc(m)-MIBI) gated myocardial perfusion imaging (G-MPI) for MD. Ninety-one patients underwent (99)Tc(m)-MIBI G-MPI examinations when they were diagnosed with Duchenne muscular dystrophy (DMD) (n=77) or Becker muscular dystrophy (BMD; n=14). (99)Tc(m)-MIBI G-MPI examinations were repeated in 43 DMD patients who received steroid treatments for 2 years as a follow-up examination. Myocardial defects were observed in nearly every segment of the left ventricular wall in both DMD and BMD patients compared with controls, especially in the inferior walls and the apices by using (99)Tc(m)-MIBI G-MPI. Cardiac wall movement impairment significantly correlated with age in the DMD and BMD groups (r s=0.534 [P<0.05] and r s=0.784 [P<0.05], respectively). Intermittent intravenous doses of glucocorticoids and continuation with oral steroid treatments significantly improved myocardial function in DMD patients (P<0.05), but not in BMD patients. (99)Tc(m)-MIBI G-MPI is a sensitive and safe approach for early evaluation of cardiomyopathy in patients with DMD or BMD, and can serve as a candidate method for the evaluation of progression, prognosis, and assessment of the effect of glucocorticoid treatment in these patients.

  14. Targeted Imaging of the Spatial and Temporal Variation of Matrix Metalloproteinase Activity in Porcine Model of Post-Infarct Remodeling: Relationship to Myocardial Dysfunction

    PubMed Central

    Sahul, Zakir H.; Mukherjee, Rupak; Song, James; McAteer, Jarod; Stroud, Robert E.; Dione, Donald P.; Staib, Lawrence; Papademetris, Xenophon; Dobrucki, Lawrence W.; Duncan, James S.; Spinale, Francis G.; Sinusas, Albert J.

    2011-01-01

    Background Matrix metalloproteinases (MMPs) are known to modulate left ventricular (LV) remodeling after a myocardial infarction (MI). However, the temporal and spatial variation of MMP activation and their relationship to mechanical dysfunction post MI remains undefined. Methods and Results MI was surgically induced in pigs (n=23) and cine MR and dual isotope hybrid SPECT/CT imaging obtained using thallium-201 (201Tl) and a technetium-99m labeled MMP targeted tracer (99mTc-RP805) at 1, 2 and 4 weeks post MI along with controls (n=5). Regional myocardial strain was computed from MR images and related to MMP zymography and ex vivo myocardial 99mTc-RP805 retention. MMP activation as assessed by in vivo and ex vivo 99mTc-RP805 imaging/retention studies was increased nearly 5-fold within the infarct region at 1 week post-MI and remained elevated up to 1 month post-MI. The post-MI change in LV end-diastolic volumes was correlated with MMP activity (y=31.34e0.48x, p=0.04). MMP activity was increased within the border and remote regions early post-MI, but declined over 1 month. There was a high concordance between regional 99mTc-RP805 uptake and ex vivo MMP-2 activity. Conclusions A novel, multimodality non-invasive hybrid SPECT/CT imaging approach was validated and applied for in vivo evaluation of MMP activation in combination with cine MR analysis of LV deformation. Increased 99mTc-RP805 retention was seen throughout the heart early post-MI and was not purely a reciprocal of 201Tl perfusion. 99mTc-RP805 SPECT/CT imaging may provide unique information regarding regional myocardial MMP activation and predict late post-MI LV remodeling. PMID:21505092

  15. Minimizing rubidium-82 tracer activity for relative PET myocardial perfusion imaging.

    PubMed

    Huizing, Eline D; van Dijk, Joris D; van Dalen, Jorn A; Timmer, Jorik R; Arkies, Hester; Slump, Cees H; Jager, Pieter L

    2017-08-01

    Recommended rubidium-82 activities for relative myocardial perfusion imaging (MPI) using present-generation PET scanners may be unnecessarily high. Our aim was to derive the minimum activity for a reliable relative PET MPI assessment. We analyzed 140 scans from 28 consecutive patients who underwent rest-stress MPI-PET (Ingenuity TF). Scans of 852, 682, 511, and 341 MBq were simulated from list-mode data and compared with a reference scan using 1023 MBq. Differences in the summed rest score, total perfusion deficit, and image quality were obtained between the reference and each of the simulated rest scans. Combined stress-rest scans obtained at a selected activity of 682 MBq were diagnostically interpreted by experts and outcome was compared with the reference scan interpretation. Differences in summed rest score more than or equal to 3 were found using 682, 511, and 341 MBq in two (7%), four (14%), and five (18%) patients, respectively. Differences in total perfusion deficit more than 7% were only found at 341 MBq in one patient. Image quality deteriorated significantly only for the 341 MBq scans (P<0.001). Interpretation of stress-rest scans did not differ between 682 and 1023 MBq scans. A significant reduction in administered Rb-82 activity is feasible in relative MPI. An activity of 682 MBq resulted in reliable diagnostic outcomes and image quality, and can therefore be considered for clinical adoption.

  16. An unsupervised approach for measuring myocardial perfusion in MR image sequences

    NASA Astrophysics Data System (ADS)

    Discher, Antoine; Rougon, Nicolas; Preteux, Francoise

    2005-08-01

    Quantitatively assessing myocardial perfusion is a key issue for the diagnosis, therapeutic planning and patient follow-up of cardio-vascular diseases. To this end, perfusion MRI (p-MRI) has emerged as a valuable clinical investigation tool thanks to its ability of dynamically imaging the first pass of a contrast bolus in the framework of stress/rest exams. However, reliable techniques for automatically computing regional first pass curves from 2D short-axis cardiac p-MRI sequences remain to be elaborated. We address this problem and develop an unsupervised four-step approach comprising: (i) a coarse spatio-temporal segmentation step, allowing to automatically detect a region of interest for the heart over the whole sequence, and to select a reference frame with maximal myocardium contrast; (ii) a model-based variational segmentation step of the reference frame, yielding a bi-ventricular partition of the heart into left ventricle, right ventricle and myocardium components; (iii) a respiratory/cardiac motion artifacts compensation step using a novel region-driven intensity-based non rigid registration technique, allowing to elastically propagate the reference bi-ventricular segmentation over the whole sequence; (iv) a measurement step, delivering first-pass curves over each region of a segmental model of the myocardium. The performance of this approach is assessed over a database of 15 normal and pathological subjects, and compared with perfusion measurements delivered by a MRI manufacturer software package based on manual delineations by a medical expert.

  17. Position of Subcutaneous Implantable Cardioverter-Defibrillators and Possible Interference on Myocardial Perfusion Imaging.

    PubMed

    Kahaly, Omar Ray; Shafiei, Fereidoon; Hardebeck, Charles; Houmsse, Mahmoud

    2017-06-01

    Implanted cardioverter-defibrillators can prevent sudden cardiac death in at-risk patients. In comparison with conventional transvenous systems, entirely subcutaneous implantable cardioverter-defibrillators have produced similar reductions in the rate of sudden cardiac death but with fewer sequelae. An infrequently reported drawback of subcutaneous devices, however, is the potential for generating attenuation artifact during nuclear myocardial perfusion imaging. We had concerns about potential attenuation artifact in a 65-year-old man with coronary artery disease but found that having positioned the pulse generator in the midaxillary zone avoided problems.

  18. Time course evaluation of myocardial perfusion after reperfusion therapy by 99mTc-tetrofosmin SPECT in patients with acute myocardial infarction.

    PubMed

    Tanaka, R; Nakamura, T

    2001-09-01

    Myocardial perfusion imaging with 99mTc-labeled agents immediately after reperfusion therapy can underestimate myocardial salvage. It is also conceivable that delayed imaging is useful for assessing the risk area. However, to our knowledge, very few studies have sequentially evaluated these image changes. We conducted 99mTc-tetrofosmin (TF) and 123I-beta-methyl-p-iodophenylpentadecanoic acid (BMIPP) SPECT before and after reperfusion to treat acute myocardial infarction and quantified changes in TF myocardial accumulation and reverse redistribution. Seventeen patients with a first myocardial infarction underwent successful reperfusion. We examined SPECT images obtained at the onset (preimage), those acquired 30 min (early image) and 6 h (delayed image) after TF injection, and images acquired 1, 4, 7, and 20 d after reperfusion (post-1-d, post-4-d, post-7-d, and post-20-d image, respectively). We also examined BMIPP SPECT images after 7 +/- 1.8 d (BMIPP image). Polar maps were divided into 48 segments to calculate percentage uptake, and time course changes in segment numbers below 60% were observed as abnormal area. Moreover, cardiac function was analyzed by gated TF SPECT on 1 and 20 d after reperfusion. In reference to the abnormal area on the early images, the post-1-d image was significantly improved compared with the preimage (P < 0.01) as was the post-7-d image compared with the post-1-d and post-4-d images (P < 0.05, respectively). However, post-20-d and post-7-d images did not significantly differ. Therefore, the improvement in myocardial accumulation reached a plateau 7 d after reperfusion. On the other hand, the abnormal area on the delayed images was significantly greater (P < 0.01) compared with that on the early images from 4 to 20 d after reperfusion, as the value was essentially constant. The correlations of the abnormal area between the preimage and the post-7-d delayed image, the preimage and the BMIPP image, and the post-7-d delayed image and the

  19. Quantitative Analysis of First-Pass Contrast-Enhanced Myocardial Perfusion Multidetector CT Using a Patlak Plot Method and Extraction Fraction Correction During Adenosine Stress

    NASA Astrophysics Data System (ADS)

    Ichihara, Takashi; George, Richard T.; Silva, Caterina; Lima, Joao A. C.; Lardo, Albert C.

    2011-02-01

    The purpose of this study was to develop a quantitative method for myocardial blood flow (MBF) measurement that can be used to derive accurate myocardial perfusion measurements from dynamic multidetector computed tomography (MDCT) images by using a compartment model for calculating the first-order transfer constant (K1) with correction for the capillary transit extraction fraction (E). Six canine models of left anterior descending (LAD) artery stenosis were prepared and underwent first-pass contrast-enhanced MDCT perfusion imaging during adenosine infusion (0.14-0.21 mg/kg/min). K1 , which is the first-order transfer constant from left ventricular (LV) blood to myocardium, was measured using the Patlak plot method applied to time-attenuation curve data of the LV blood pool and myocardium. The results were compared against microsphere MBF measurements, and the extraction fraction of contrast agent was calculated. K1 is related to the regional MBF as K1=EF, E=(1-exp(-PS/F)), where PS is the permeability-surface area product and F is myocardial flow. Based on the above relationship, a look-up table from K1 to MBF can be generated and Patlak plot-derived K1 values can be converted to the calculated MBF. The calculated MBF and microsphere MBF showed a strong linear association. The extraction fraction in dogs as a function of flow (F) was E=(1-exp(-(0.2532F+0.7871)/F)) . Regional MBF can be measured accurately using the Patlak plot method based on a compartment model and look-up table with extraction fraction correction from K1 to MBF.

  20. New Trends in Radionuclide Myocardial Perfusion Imaging

    PubMed Central

    Hung, Guang-Uei; Wang, Yuh-Feng; Su, Hung-Yi; Hsieh, Te-Chun; Ko, Chi-Lun; Yen, Ruoh-Fang

    2016-01-01

    Radionuclide myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) has been widely used clinically as one of the major functional imaging modalities for patients with coronary artery disease (CAD) for decades. Ample evidence has supported the use of MPI as a useful and important tool in the diagnosis, risk stratification and treatment planning for CAD. Although popular in the United States, MPI has become the most frequently used imaging modality among all nuclear medicine tests in Taiwan. However, it should be acknowledged that MPI SPECT does have its limitations. These include false-positive results due to certain artifacts, false-negative due to balanced ischemia, complexity and adverse reaction arising from current pharmacological stressors, time consuming nature of the imaging procedure, no blood flow quantitation and relatively high radiation exposure. The purpose of this article was to review the recent trends in nuclear cardiology, including the utilization of positron emission tomography (PET) for MPI, new stressor, new SPECT camera with higher resolution and higher sensitivity, dynamic SPECT protocol for blood flow quantitation, new software of phase analysis for evaluation of LV dyssynchrony, and measures utilized for reducing radiation exposure of MPI. PMID:27122946

  1. Neonatal repair of right interrupted aortic arch with cerebro-myocardial perfusion technique.

    PubMed

    Takeuchi, Koh; Masuzawa, Akihiro; Kobayashi, Jotaro; Tsuchiya, Keiji

    2011-10-01

    Right interrupted aortic arch and descending aorta is exceedingly rare and most likely cause respiratory presentation, since patent ductus arteriosus (PDA) courses over the right mainstem bronchus. We report a case of successful neonatal biventricular repair of a right interrupted aortic arch (type B), with an aberrant right subclavian artery ventricular septal defect (VSD) in a 2.7 kg term neonate with DiGeorge syndrome. Patient presented in severe respiratory distress and acidosis at one day old. Two-dimensional (2D) echocardiography revealed aortic arch interruption beyond the common carotid arteries with large perimembranous outlet VSD. Aortic annulus diameter was 4.8 mm and there was no left ventricle (LV) outflow tract obstruction. Three-dimensional (3D) CT-scan confirmed these findings and identified a right-sided ductal arch that continued over the right mainstem bronchus into a right-sided descending aorta and aberrant right subclavian artery. Brachiocephalic perfusion and ductal perfusion was employed for cooling during cardiopulmonary bypass. Under deep hypothermia (27 °C rectal temperature), selective cerebro-myocardial perfusion was used for successful aortic arch repair without sacrificing the aberrant right subclavian artery. A direct tension-free anastomosis was attained. Her postoperative course was uneventful and her respiratory symptoms disappeared postoperatively. Early surgical correction is mandatory for these patients with unique anatomy and presentation.

  2. Prediction of revascularization after myocardial perfusion SPECT by machine learning in a large population.

    PubMed

    Arsanjani, Reza; Dey, Damini; Khachatryan, Tigran; Shalev, Aryeh; Hayes, Sean W; Fish, Mathews; Nakanishi, Rine; Germano, Guido; Berman, Daniel S; Slomka, Piotr

    2015-10-01

    We aimed to investigate if early revascularization in patients with suspected coronary artery disease can be effectively predicted by integrating clinical data and quantitative image features derived from perfusion SPECT (MPS) by machine learning (ML) approach. 713 rest (201)Thallium/stress (99m)Technetium MPS studies with correlating invasive angiography with 372 revascularization events (275 PCI/97 CABG) within 90 days after MPS (91% within 30 days) were considered. Transient ischemic dilation, stress combined supine/prone total perfusion deficit (TPD), supine rest and stress TPD, exercise ejection fraction, and end-systolic volume, along with clinical parameters including patient gender, history of hypertension and diabetes mellitus, ST-depression on baseline ECG, ECG and clinical response during stress, and post-ECG probability by boosted ensemble ML algorithm (LogitBoost) to predict revascularization events. These features were selected using an automated feature selection algorithm from all available clinical and quantitative data (33 parameters). Tenfold cross-validation was utilized to train and test the prediction model. The prediction of revascularization by ML algorithm was compared to standalone measures of perfusion and visual analysis by two experienced readers utilizing all imaging, quantitative, and clinical data. The sensitivity of machine learning (ML) (73.6% ± 4.3%) for prediction of revascularization was similar to one reader (73.9% ± 4.6%) and standalone measures of perfusion (75.5% ± 4.5%). The specificity of ML (74.7% ± 4.2%) was also better than both expert readers (67.2% ± 4.9% and 66.0% ± 5.0%, P < .05), but was similar to ischemic TPD (68.3% ± 4.9%, P < .05). The receiver operator characteristics areas under curve for ML (0.81 ± 0.02) was similar to reader 1 (0.81 ± 0.02) but superior to reader 2 (0.72 ± 0.02, P < .01) and standalone measure of perfusion (0.77 ± 0.02, P < .01). ML approach is comparable or better than

  3. Prognostic value of myocardial perfusion SPECT versus exercise electrocardiography in patients with ST-segment depression on resting electrocardiography.

    PubMed

    De Lorenzo, Andrea; Hachamovitch, Rory; Kang, Xingping; Gransar, Heidi; Sciammarella, Maria G; Hayes, Sean W; Friedman, John D; Cohen, Ishac; Germano, Guido; Berman, Daniel S

    2005-01-01

    The value of exercise-induced ST-segment depression for the prognostic evaluation of patients with 1 mm of ST depression or greater on the resting electrocardiogram is controversial. Patients who underwent exercise myocardial perfusion single photon emission computed tomography (MPS) and had resting ST depression of 1 mm or greater with a nondiagnostic exercise electrocardiographic response (n = 1122) were followed up for 3.4 +/- 2.3 years. Those with paced rhythm, pre-excitation, left bundle branch block, or myocardial revascularization within the first 60 days after MPS were excluded. Additional exercise-induced ST-segment depression was considered significant if > or = 2 mm MPS was scored semiquantitatively by use of a 20-segment model of the left ventricle; the percentage of myocardium involved with stress defects (% myo) was derived by normalizing to the maximal possible score of 80. Hard events were defined as nonfatal myocardial infarction or cardiac death. A Cox analysis was used to determine independent predictors of hard events among clinical, exercise, and nuclear variables. Hard event rates increased as a function of % myo for either patients with exercise-induced ST depression (1.4%/y for normal MPS vs 4.1%/y for % myo >10%, P < .03) or those without it (0.7%/y for normal MPS vs 3.0%/y for % myo >10%, P = .0001). Age, diabetes mellitus, shortness of breath as the presenting symptom, and % myo were independent predictors of hard events. Exercise-induced ST depression was predictive of hard events only when it was 3 mm or greater. The presence and extent of perfusion defects, reflected in the % myo, had incremental prognostic value over clinical variables and also over all degrees of exercise-induced ST depression. Although MPS effectively risk-stratifies patients with resting ST depression of 1 mm or greater, the prognostic value of exercise-induced ST depression is limited in these patients, with a small added risk when severe (> or = 3 mm).

  4. Usefulness of the novel risk estimation software, Heart Risk View, for the prediction of cardiac events in patients with normal myocardial perfusion SPECT.

    PubMed

    Sakatani, Tomohiko; Shimoo, Satoshi; Takamatsu, Kazuaki; Kyodo, Atsushi; Tsuji, Yumika; Mera, Kayoko; Koide, Masahiro; Isodono, Koji; Tsubakimoto, Yoshinori; Matsuo, Akiko; Inoue, Keiji; Fujita, Hiroshi

    2016-12-01

    Myocardial perfusion single-photon emission-computed tomography (SPECT) can predict cardiac events in patients with coronary artery disease with high accuracy; however, pseudo-negative cases sometimes occur. Heart Risk View, which is based on the prospective cohort study (J-ACCESS), is a software for evaluating cardiac event probability. We examined whether Heart Risk View was useful to evaluate the cardiac risk in patients with normal myocardial perfusion SPECT (MPS). We studied 3461 consecutive patients who underwent MPS to detect myocardial ischemia and those who had normal MPS were enrolled in this study (n = 698). We calculated cardiac event probability by Heart Risk View and followed-up for 3.8 ± 2.4 years. The cardiac events were defined as cardiac death, non-fatal myocardial infarction, and heart failure requiring hospitalization. During the follow-up period, 21 patients (3.0 %) had cardiac events. The event probability calculated by Heart Risk View was higher in the event group (5.5 ± 2.6 vs. 2.9 ± 2.6 %, p < 0.001). According to the receiver-operating characteristics curve, the cut-off point of the event probability for predicting cardiac events was 3.4 % (sensitivity 0.76, specificity 0.72, and AUC 0.85). Kaplan-Meier curves revealed that a higher event rate was observed in the high-event probability group by the log-rank test (p < 0.001). Although myocardial perfusion SPECT is useful for the prediction of cardiac events, risk estimation by Heart Risk View adds more prognostic information, especially in patients with normal MPS.

  5. Sevoflurane postconditioning improves myocardial mitochondrial respiratory function and reduces myocardial ischemia-reperfusion injury by up-regulating HIF-1

    PubMed Central

    Yang, Long; Xie, Peng; Wu, Jianjiang; Yu, Jin; Yu, Tian; Wang, Haiying; Wang, Jiang; Xia, Zhengyuan; Zheng, Hong

    2016-01-01

    Background: Sevoflurane postconditioning (SPostC) can exert myocardial protective effects similar to ischemic preconditioning. However, the exact myocardial protection mechanism by SPostC is unclear. Studies indicate that hypoxia-inducible factor-1 (HIF-1) maintains cellular respiration homeostasis by regulating mitochondrial respiratory chain enzyme activity under hypoxic conditions. This study investigated whether SPostC could regulate the expression of myocardial HIF-1α and to improve mitochondrial respiratory function, thereby relieving myocardial ischemia-reperfusion injury in rats. Methods: The myocardial ischemia-reperfusion rat model was established using the Langendorff isolated heart perfusion apparatus. Additionally, postconditioning was performed using sevoflurane alone or in combination with the HIF-1α inhibitor 2-methoxyestradiol (2ME2). The changes in hemodynamic parameters, HIF-1α protein expression levels, mitochondrial respiratory function and enzyme activity, mitochondrial reactive oxygen species (ROS) production rates, and mitochondrial ultrastructure were measured or observed. Results: Compared to the ischemia-reperfusion (I/R) group, HIF-1α expression in the SPostC group was significantly up-regulated. Additionally, cardiac function indicators, mitochondrial state 3 respiratory rate, respiratory control ratio (RCR), cytochrome C oxidase (CcO), NADH oxidase (NADHO), and succinate oxidase (SUCO) activities, mitochondrial ROS production rate, and mitochondrial ultrastructure were significantly better than those in the I/R group. However, these advantages were completely reversed by the HIF-1α specific inhibitor 2ME2 (P<0.05). Conclusion: The myocardial protective function of SPostC might be associated with the improvement of mitochondrial respiratory function after up-regulation of HIF-1α expression. PMID:27830025

  6. Sevoflurane postconditioning improves myocardial mitochondrial respiratory function and reduces myocardial ischemia-reperfusion injury by up-regulating HIF-1.

    PubMed

    Yang, Long; Xie, Peng; Wu, Jianjiang; Yu, Jin; Yu, Tian; Wang, Haiying; Wang, Jiang; Xia, Zhengyuan; Zheng, Hong

    2016-01-01

    Sevoflurane postconditioning (SPostC) can exert myocardial protective effects similar to ischemic preconditioning. However, the exact myocardial protection mechanism by SPostC is unclear. Studies indicate that hypoxia-inducible factor-1 (HIF-1) maintains cellular respiration homeostasis by regulating mitochondrial respiratory chain enzyme activity under hypoxic conditions. This study investigated whether SPostC could regulate the expression of myocardial HIF-1α and to improve mitochondrial respiratory function, thereby relieving myocardial ischemia-reperfusion injury in rats. The myocardial ischemia-reperfusion rat model was established using the Langendorff isolated heart perfusion apparatus. Additionally, postconditioning was performed using sevoflurane alone or in combination with the HIF-1α inhibitor 2-methoxyestradiol (2ME2). The changes in hemodynamic parameters, HIF-1α protein expression levels, mitochondrial respiratory function and enzyme activity, mitochondrial reactive oxygen species (ROS) production rates, and mitochondrial ultrastructure were measured or observed. Compared to the ischemia-reperfusion (I/R) group, HIF-1α expression in the SPostC group was significantly up-regulated. Additionally, cardiac function indicators, mitochondrial state 3 respiratory rate, respiratory control ratio (RCR), cytochrome C oxidase (C c O), NADH oxidase (NADHO), and succinate oxidase (SUCO) activities, mitochondrial ROS production rate, and mitochondrial ultrastructure were significantly better than those in the I/R group. However, these advantages were completely reversed by the HIF-1α specific inhibitor 2ME2 ( P <0.05). The myocardial protective function of SPostC might be associated with the improvement of mitochondrial respiratory function after up-regulation of HIF-1α expression.

  7. [Myocardial imaging in acute myocardial infarction using beta-methyl-p-(123I)-iodophenylpentadecanoic acid: comparison with 201Tl imaging and wall motion].

    PubMed

    Naruse, H; Itano, M; Kondo, T; Kogame, T; Yamamoto, J; Morita, M; Kawamoto, H; Fukutake, N; Ohyanagi, M; Iwasaki, T

    1992-01-01

    Myocardial imaging using beta-methyl-p-(123I)-iodophenylpentadecanoic acid (BMIPP) was performed in 11 patients with acute myocardial infarction. The left ventricular images were divided into 12 segments, and myocardial imagings with BMIPP were compared with coronary angiography (CAG), thallium-201 myocardial scintigraphy (TL) and wall motion obtained by two-dimensional echocardiography (WM). When the culprit lesion was at the proximal point of the left anterior descending artery (LAD), all segments showed depressed uptake. In 3 cases with single vessel disease of the LAD, inferior wall of the basis showed reduced uptake of BMIPP despite the location of the culprit lesion. In cases with discordant uptake between the two tracers, BMIPP frequently showed more severely depressed uptake than TL in the subacute phase, although the uptake of BMIPP correlated with that of TL (tau = 0.82, p less than 0.001). In such cases, the discordance was related to the improvement in WM from the acute phase to the convalescent phase. BMIPP uptake correlated with WM in the subacute phase (tau = 0.50, p less than 0.001). BMIPP showed more severely depressed uptake while WM showed mild asynergy in most cases in which discordance was found between the BMIPP and WM findings. However, there was no correlation between the change in WM from the acute to subacute phases, or the uptakes of BMIPP and TL alone. We concluded that the myocardial condition can be evaluated in detail in acute myocardial infarction by comparing the findings of BMIPP with those of TL and WM.

  8. Persistent T-wave inversion predicts myocardial damage after ST-elevation myocardial infarction.

    PubMed

    Reindl, Martin; Reinstadler, Sebastian Johannes; Feistritzer, Hans-Josef; Niess, Lea; Koch, Constantin; Mayr, Agnes; Klug, Gert; Metzler, Bernhard

    2017-08-15

    Persistent T-wave inversion (PTI) after ST-elevation myocardial infarction (STEMI) is associated with worse clinical outcome; however, the underlying mechanism between PTI and poor prognosis is incompletely understood. We sought to investigate the relationship between PTI and myocardial damage assessed by cardiac magnetic resonance (CMR) following STEMI. In this prospective observational study, we included 142 consecutive revascularized STEMI patients. Electrocardiography to determine the presence and amplitude of PTI and pathological Q-waves was conducted 4months after infarction. CMR was performed within 1week after infarction and at 4months follow-up to evaluate infarct characteristics and myocardial function. Patients with PTI (n=103, 73%) showed a larger acute (21[11-29] vs. 6[1-13]%; p<0.001) and chronic infarct size (IS) (14[8-19] vs. 3[1-8]%; p<0.001) and more frequently microvascular obstruction (59 vs. 33%; p=0.02). The association between PTI and chronic IS remained significant (odds ratio: 9.02, 95%CI 3.49-23.35; p<0.001) after adjustment for pathological Q-wave and other IS estimators (high-sensitivity cardiac troponin T and C-reactive protein, N-terminal pro B-type natriuretic peptide, culprit vessel, pre-interventional TIMI flow). The value of PTI amplitude for the prediction of large chronic IS>11% (AUC: 0.84, 95%CI 0.77-0.90) was significantly higher compared to Q-wave amplitude (AUC: 0.72, 95%CI 0.63-0.80; p=0.009); the combination of PTI with pathological Q-wave (Q-wave/T-wave score) led to a net reclassification improvement of 0.43 (95% CI 0.29-0.57; p<0.001) as compared to PTI alone. PTI following STEMI is independently and incrementally associated with more extensive myocardial damage as visualized by CMR. An electrocardiographic score combining PTI with pathological Q-wave allows for a highly accurate IS estimation post-STEMI. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Improved First Pass Spiral Myocardial Perfusion Imaging with Variable Density Trajectories

    PubMed Central

    Salerno, Michael; Sica, Christopher; Kramer, Christopher M.; Meyer, Craig H.

    2013-01-01

    Purpose To develop and evaluate variable-density (VD) spiral first-pass perfusion pulse sequences for improved efficiency and off-resonance performance and to demonstrate the utility of an apodizing density compensation function (DCF) to improve SNR and reduce dark-rim artifact caused by cardiac motion and Gibbs Ringing. Methods Three variable density spiral trajectories were designed, simulated, and evaluated in 18 normal subjects, and in 8 patients with cardiac pathology on a 1.5T scanner. Results By utilizing a density compensation function (DCF) which intentionally apodizes the k-space data, the side-lobe amplitude of the theoretical PSF is reduced by 68%, with only a 13% increase in the FWHM of the main-lobe as compared to the same data corrected with a conventional VD DCF, and has an 8% higher resolution than a uniform density spiral with the same number of interleaves and readout duration. Furthermore, this strategy results in a greater than 60% increase in measured SNR as compared to the same VD spiral data corrected with a conventional DCF (p<0.01). Perfusion defects could be clearly visualized with minimal off-resonance and dark-rim artifacts. Conclusion VD spiral pulse sequences using an apodized DCF produce high-quality first-pass perfusion images with minimal dark-rim and off-resonance artifacts, high SNR and CNR and good delineation of resting perfusion abnormalities. PMID:23280884

  10. Pitfalls in classical nuclear medicine: myocardial perfusion imaging

    NASA Astrophysics Data System (ADS)

    Fragkaki, C.; Giannopoulou, Ch

    2011-09-01

    Scintigraphic imaging is a complex functional procedure subject to a variety of artefacts and pitfalls that may limit its clinical and diagnostic accuracy. It is important to be aware of and to recognize them when present and to eliminate them whenever possible. Pitfalls may occur at any stage of the imaging procedure and can be related with the γ-camera or other equipment, personnel handling, patient preparation, image processing or the procedure itself. Often, potential causes of artefacts and pitfalls may overlap. In this short review, special interest will be given to cardiac scintigraphic imaging. Most common causes of artefact in myocardial perfusion imaging are soft tissue attenuation as well as motion and gating errors. Additionally, clinical problems like cardiac abnormalities may cause interpretation pitfalls and nuclear medicine physicians should be familiar with these in order to ensure the correct evaluation of the study. Artefacts or suboptimal image quality can also result from infiltrated injections, misalignment in patient positioning, power instability or interruption, flood field non-uniformities, cracked crystal and several other technical reasons.

  11. Nitrogen-13-labeled ammonia for myocardial imaging.

    PubMed

    Walsh, W F; Fill, H R; Harper, P V

    1977-01-01

    Cyclotron-produced nitrogen-13 (half-life 10 min), as labeled ammonia (13NH4+), has been evaluated as a myocardial perfusion imaging agent. The regional myocardial uptake of 13NH4+ has been shown to be proportional to regional tissue perfusion in animal studies. Intravenously administered 13NH4+ is rapidly cleared from the circulation, being extracted by the liver (15%), lungs, myocardium (2%-4%), brain, kidney, and bladder. Myocardial ammonia is metabolized mainly to glutamine via the glutamine synthetase pathway. Pulmonary uptake is substantial, but usually transient, except in smokers where clearance may be delayed. The position annihilation irradiation (511 keV) of 13N may be imaged with a scintillation camera, using either a specially designed tungsten collimator or a pinhole collimator. After early technical problems with collimation and the production method of 13NH4+ were overcome, reproducible high quality myocardial images were consistently obtained. The normal myocardial image was established to be of a homogeneous "doughnut" configuration. Imaging studies performed in patients with varying manifestations of ischemic and valvular heart disease showed a high incidence of localized perfusion defects, especially in patients with acute myocardial infarction. Sequential studies at short intervals in patients with acute infarction showed correlation between alterations in regional perfusion and the clinical course of the patient. It is concluded that myocardial imaging with 13NH4+ and a scintillation camera provides a valid and noninvasive means of assessing regional myocardial perfusion. This method is especially suitable for sequential studies of acute cardiac patients at short intervals. Coincidence imaging of the 511 keV annihilation irradiation provides a tomographic and potentially quantitative assessment of the regional myocardial uptake of 13NH4+.

  12. Cardiac sarcoidosis demonstrated by Tl-201 and Ga-67 SPECT imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taki, J.; Nakajima, K.; Bunko, H.

    1990-09-01

    Ga-67 and Tl-201 SPECT was performed to evaluate cardiac sarcoidosis in a 15-year-old boy. Tl-201 SPECT imaging showed decreased uptake in the inferior to lateral wall and Ga-67 accumulation in the area of decreased Tl-201 uptake. These findings suggested cardiac sarcoidosis, and cardiac biopsy confirmed this diagnosis. After corticosteroid therapy, myocardial uptake of Ga-67 disappeared and myocardial TI-201 uptake became more homogeneous.

  13. The role of T1 perfusion-based classification in magnetic resonance-guided high-intensity focused ultrasound ablation of uterine fibroids.

    PubMed

    Keserci, Bilgin; Duc, Nguyen Minh

    2017-12-01

    To comparatively evaluate the role of magnetic resonance (MR) T1 perfusion-based time-signal intensity (SI) curves of fibroid tissue and the myometrium in classification of fibroids for predicting treatment outcomes of high-intensity focused ultrasound (HIFU) treatment. The fibroids of 74 women who underwent MR-HIFU treatment were classified into group A (time-SI curve of fibroid lower than that of the myometrium) and group B (time-SI curve of fibroid equal to or higher than that of the myometrium). Non-perfused volume (NPV) ratios immediately after treatment and fibroid volume reduction ratios and symptom severity scores (SSS) at the 6-month follow-up were retrospectively assessed. The immediate NPV ratios in groups A and B were 95.3 ± 6.3% (n = 62) and 63.8 ± 11% (n = 12), respectively. At the 6-month follow-up, the fibroid volume reduction ratios in groups A and B were 0.52 ± 0.14 (n = 50) and 0.07 ± 0.14 (n = 11), with the corresponding improvement in mean transformed SSS being 0.86 ± 0.14 and 0.19 ± 0.3, respectively. No serious adverse effects were reported. Our novel classification method could play an important role in classifying fibroids for predicting the immediate outcomes of HIFU treatment. • MRI is an important modality for outcome prediction in HIFU treatment • Patient selection is a significant factor for achieving high NPV ratio • NPV ratio is very strongly correlated with T1 perfusion-based classification • T1 perfusion-based classification is a strong predictor of treatment outcome.

  14. Regional Myocardial Blood Volume and Flow: First-Pass MR Imaging with Polylysine-Gd-DTPA

    PubMed Central

    Wilke, Norbert; Kroll, Keith; Merkle, Hellmut; Wang, Ying; Ishibashi, Yukata; Xu, Ya; Zhang, Jiani; Jerosch-Herold, Michael; Mühler, Andreas; Stillman, Arthur E.; Bassingthwaighte, James B.; Bache, Robert; Ugurbil, Kamil

    2010-01-01

    The authors investigated the utility of an intravascular magnetic resonance (MR) contrast agent, poly-L-lysine-gadolinium diethylenetriaminepentaacetic acid (DTPA), for differentiating acutely ischemic from normally perfused myocardium with first-pass MR imaging. Hypoperfused regions, identified with microspheres, on the first-pass images displayed significantly decreased signal intensities compared with normally perfused myocardium (P < .0007). Estimates of regional myocardial blood content, obtained by measuring the ratio of areas under the signal intensity-versus-time curves in tissue regions and the left ventricular chamber, averaged 0.12 mL/g ± 0.04 (n = 35), compared with a value of 0.11 mL/g ± 0.05 measured with radiolabeled albumin in the same tissue regions. To obtain MR estimates of regional myocardial blood flow, in situ calibration curves were used to transform first-pass intensity-time curves into content-time curves for analysis with a multiple-pathway, axially distributed model. Flow estimates, obtained by automated parameter optimization, averaged 1.2 mL/min/g ± 0.5 [n = 29), compared with 1.3 mL/min/g ± 0.3 obtained with tracer microspheres in the same tissue specimens at the same time. The results represent a combination of T1-weighted first-pass imaging, intravascular relaxation agents, and a spatially distributed perfusion model to obtain absolute regional myocardial blood flow and volume. PMID:7766986

  15. CD4+ Foxp3+ T-cells contribute to myocardial ischemia-reperfusion injury.

    PubMed

    Mathes, Denise; Weirather, Johannes; Nordbeck, Peter; Arias-Loza, Anahi-Paula; Burkard, Matthias; Pachel, Christina; Kerkau, Thomas; Beyersdorf, Niklas; Frantz, Stefan; Hofmann, Ulrich

    2016-12-01

    The present study analyzed the effect of CD4 + Forkhead box protein 3 negative (Foxp3 - ) T-cells and Foxp3 + CD4 + T-cells on infarct size in a mouse myocardial ischemia-reperfusion model. We examined the infarct size as a fraction of the area-at-risk as primary study endpoint in mice after 30minutes of coronary ligation followed by 24hours of reperfusion. CD4 + T-cell deficient MHC-II KO mice showed smaller histologically determined infarct size (34.5±4.7% in MHCII KO versus 59.4±4.9% in wildtype (WT)) and better preserved ejection fraction determined by magnetic resonance tomography (56.9±2.8% in MHC II KO versus 39.0±4.2% in WT). MHC-II KO mice also displayed better microvascular perfusion than WT mice after 24hours of reperfusion. Also CD4 + T-cell sufficient OT-II mice, which express an in this context irrelevant T-cell receptor, revealed smaller infarct sizes compared to WT mice. However, MHC-II blocking anti-I-A/I-E antibody treatment was not able to reduce infarct size indicating that autoantigen recognition is not required for the activation of CD4 + T-cells during reperfusion. Flow-cytometric analysis also did not detect CD4 + T-cell activation in heart draining lymph nodes in response to 24hours of ischemia-reperfusion. Adoptive transfer of CD4 + T-cells in CD4 KO mice increased the infarct size only when including the Foxp3 + CD25 + subset. Depletion of CD4 + Foxp3 + T-cells in DEREG mice enabling specific conditional ablation of this subset by treatment with diphtheria toxin attenuated infarct size as compared to diphtheria toxin treated WT mice. CD4 + Foxp3 + T-cells enhance myocardial ischemia-reperfusion injury. CD4 + T-cells exert injurious effects without the need for prior activation by MHC-II restricted autoantigen recognition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Correction of Hysteretic Respiratory Motion in SPECT Myocardial Perfusion Imaging: Simulation and Patient Studies

    PubMed Central

    Dasari, Paul K. R.; Könik, Arda; Pretorius, P. Hendrik; Johnson, Karen L.; Segars, William P.; Shazeeb, Mohammed. S.; King, Michael A.

    2017-01-01

    Purpose Amplitude based respiratory gating is known to capture the extent of respiratory motion (RM) accurately but results in residual motion in the presence of respiratory hysteresis. In our previous study, we proposed and developed a novel approach to account for respiratory hysteresis by applying the Bouc-Wen (BW) model of hysteresis to external surrogate signals of anterior / posterior motion of the abdomen and chest with respiration. In this work using simulated and clinical SPECT myocardial perfusion imaging (MPI) studies, we investigate the effects of respiratory hysteresis and evaluate the benefit of correcting it using the proposed BW model in comparison with the abdomen signal typically employed clinically. Methods The MRI navigator data acquired in free breathing human volunteers were used in the specially modified 4-D NCAT phantoms to allow simulating three types of respiratory patterns: monotonic, mild-hysteresis, and strong-hysteresis with normal myocardial uptake, and perfusion defects in the anterior, lateral, inferior, and septal locations of the mid-ventricular wall. Clinical scans were performed using a 99mTc-Sestamibi MPI protocol while recording respiratory signals from thoracic and abdomen regions using a Visual Tracking System (VTS). The performance of the correction using the respiratory signals was assessed through polar map analysis in phantom and ten clinical studies selected on the basis of having substantial RM. Results In phantom studies, simulations illustrating normal myocardial uptake showed significant differences (p<0.001) in the uniformity of the polar maps between the RM uncorrected and corrected. No significant differences were seen in the polar map uniformity across the RM corrections. Studies simulating perfusion defects showed significantly decreased errors (p<0.001) in defect severity and extent for the RM corrected compared to the uncorrected. Only for the strong-hysteretic pattern was there a significant difference (p<0

  17. Measurement of myocardial native T1 in cardiovascular diseases and norm in 1291 subjects.

    PubMed

    Liu, Joanna M; Liu, Alexander; Leal, Joana; McMillan, Fiona; Francis, Jane; Greiser, Andreas; Rider, Oliver J; Myerson, Saul; Neubauer, Stefan; Ferreira, Vanessa M; Piechnik, Stefan K

    2017-09-28

    Native T1-mapping provides quantitative myocardial tissue characterization for cardiovascular diseases (CVD), without the need for gadolinium. However, its translation into clinical practice is hindered by differences between techniques and the lack of established reference values. We provide typical myocardial T1-ranges for 18 commonly encountered CVDs using a single T1-mapping technique - Shortened Look-Locker Inversion Recovery (ShMOLLI), also used in the large UK Biobank and Hypertrophic Cardiomyopathy Registry study. We analyzed 1291 subjects who underwent CMR (1.5-Tesla, MAGNETOM-Avanto, Siemens Healthcare, Erlangen, Germany) between 2009 and 2016, who had a single CVD diagnosis, with mid-ventricular T1-map assessment. A region of interest (ROI) was placed on native T1-maps in the "most-affected myocardium", characterized by the presence of late gadolinium enhancement (LGE), or regional wall motion abnormalities (RWMA) on cines. Another ROI was placed in the "reference myocardium" as far as possible from LGE/RWMA, and in the septum if no focal abnormality was present. To further define normality, we included native T1 of healthy subjects from an existing dataset after sub-endocardial pixel-erosions. Native T1 of patients with normal CMR (938 ± 21 ms) was similar compared to healthy subjects (941 ± 23 ms). Across all patient groups (57 ± 19 yrs., 65% males), focally affected myocardium had significantly different T1 value compared to reference myocardium (all p < 0.001). In the affected myocardium, cardiac amyloidosis (1119 ± 61 ms) had the highest native T1 compared to normal and all other CVDs, while iron-overload (795 ± 58 ms) and Anderson-Fabry disease (863 ± 23 ms) had the lowest native reference T1 (all p < 0.001). Future studies designed to detect the large T1 differences between affected and reference myocardium are estimated to require small sample-sizes (n < 50). However, studies designed to detect the small T1

  18. 1 CFR 20.1 - Liaison officers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false Liaison officers. 20.1 Section 20.1 General... DOCUMENTS HANDLING OF THE UNITED STATES GOVERNMENT MANUAL STATEMENTS § 20.1 Liaison officers. (a) Each of... United States Government Manual: (1) Agencies of the legislative and judicial branches. (2) Executive...

  19. 1 CFR 20.1 - Liaison officers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 1 General Provisions 1 2011-01-01 2011-01-01 false Liaison officers. 20.1 Section 20.1 General... DOCUMENTS HANDLING OF THE UNITED STATES GOVERNMENT MANUAL STATEMENTS § 20.1 Liaison officers. (a) Each of... United States Government Manual: (1) Agencies of the legislative and judicial branches. (2) Executive...

  20. 1 CFR 20.1 - Liaison officers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 1 General Provisions 1 2013-01-01 2012-01-01 true Liaison officers. 20.1 Section 20.1 General... DOCUMENTS HANDLING OF THE UNITED STATES GOVERNMENT MANUAL STATEMENTS § 20.1 Liaison officers. (a) Each of... United States Government Manual: (1) Agencies of the legislative and judicial branches. (2) Executive...

  1. 1 CFR 20.1 - Liaison officers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 1 General Provisions 1 2012-01-01 2012-01-01 false Liaison officers. 20.1 Section 20.1 General... DOCUMENTS HANDLING OF THE UNITED STATES GOVERNMENT MANUAL STATEMENTS § 20.1 Liaison officers. (a) Each of... United States Government Manual: (1) Agencies of the legislative and judicial branches. (2) Executive...

  2. 1 CFR 20.1 - Liaison officers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 1 General Provisions 1 2014-01-01 2012-01-01 true Liaison officers. 20.1 Section 20.1 General... DOCUMENTS HANDLING OF THE UNITED STATES GOVERNMENT MANUAL STATEMENTS § 20.1 Liaison officers. (a) Each of... United States Government Manual: (1) Agencies of the legislative and judicial branches. (2) Executive...

  3. Myonecrosis following stent placement: association between impaired TIMI myocardial perfusion grade and MRI visualization of microinfarction.

    PubMed

    Choi, James W; Gibson, C Michael; Murphy, Sabina A; Davidson, Charles J; Kim, Raymond J; Ricciardi, Mark J

    2004-04-01

    Contrast-enhanced cardiac MRI (ceMRI) and TIMI myocardial perfusion grade analysis (TMPG) are proven methods for visualization of microinfarction and assessment of microvascular perfusion, respectively. To determine whether microvascular obstruction accounts for procedure-related myonecrosis, 14 poststent patients, 9 with procedural CK-MB elevation and 5 controls, underwent ceMRI and TMPG. All had TIMI 3 flow pre- and poststent. TMPG was normal in 12/14 pre- and 7/14 poststent. Those with poststent decline in TMPG had higher CK-MB (median, 41.0 vs. 7.4 ng/mL; P = 0.01) and larger infarct mass (median, 3.1 vs. 0.89 g; P = 0.04). More extensive myonecrosis (CK-MB > 3 x normal; infarct mass > 3 g) was observed more frequently if there was a poststent decline in TMPG (3/3, 100%, vs. 2/11, 18.2%; P = 0.03). These data support the theory that distal embolization and microvascular obstruction are associated with myonecrosis following otherwise successful coronary stent placement and provide further insight into its pathophysiology. Copyright 2004 Wiley-Liss, Inc.

  4. Regional glucose utilization in infarcted and remote myocardium: its relation to coronary anatomy and perfusion.

    PubMed

    Fragasso, G; Chierchia, S L; Landoni, C; Lucignani, G; Rossetti, E; Sciammarella, M; Vanoli, G E; Fazio, F

    1998-07-01

    We studied the relationship between coronary anatomy, perfusion and metabolism in myocardial segments exhibiting transient and persistent perfusion defects on stress/rest 99Tcm-MIBI single photon emission tomography in 35 patients (31 males, 4 females, mean age 56 +/- 7 years) with a previous myocardial infarction. Quantitative coronary angiography and assessment of myocardial perfusion reserve and glucose metabolism were performed within 1 week of one another. Perfusion was assessed by SPET after the intravenous injection of 740 MBq of 99Tcm-MIBI at rest and after exercise. Regional myocardial glucose metabolism was assessed by position emission tomography at rest (200 MBq of 18F-2-deoxyglucose, FDG) after an overnight fast with no glucose loading. All 35 patients exhibited persistent perfusion defects consistent with the clinically identified infarct site, and 27 (77%) also showed various degrees of within-infarct FDG uptake; 11 patients developed exercise-induced transient perfusion defects within, or in the vicinity of, 15 infarct segments and resting FDG uptake was present in 10 of these segments (67%). Five patients also showed exercise-induced transient perfusion defects in nine segments remote from the site of infarct: resting FDG uptake was present in six of these regions (67%). Finally, nine patients had increased glucose uptake in non-infarcted regions not showing transient perfusion defects upon exercise testing and perfused by coronary arteries with only minor irregularities. Our results confirm the presence of viable tissue in a large proportion of infarct sites. Moreover, FDG uptake can be seen in regions perfused by coronary arteries showing minor irregularities, not necessarily resulting in detectable transient perfusion defects on a MIBI stress scan. Since the clinical significance of such findings is not clear, further studies should be conducted to assess the long-term evolution of perfusion, function and metabolism in non

  5. Myocardial Drug Distribution Generated from Local Epicardial Application: Potential Impact of Cardiac Capillary Perfusion in a Swine Model Using Epinephrine

    PubMed Central

    Maslov, Mikhail Y.; Edelman, Elazer R.; Pezone, Matthew J.; Wei, Abraham E.; Wakim, Matthew G.; Murray, Michael R.; Tsukada, Hisashi; Gerogiannis, Iraklis S.; Groothuis, Adam; Lovich, Mark A.

    2014-01-01

    Prior studies in small mammals have shown that local epicardial application of inotropic compounds drives myocardial contractility without systemic side effects. Myocardial capillary blood flow, however, may be more significant in larger species than in small animals. We hypothesized that bulk perfusion in capillary beds of the large mammalian heart enhances drug distribution after local release, but also clears more drug from the tissue target than in small animals. Epicardial (EC) drug releasing systems were used to apply epinephrine to the anterior surface of the left heart of swine in either point-sourced or distributed configurations. Following local application or intravenous (IV) infusion at the same dose rates, hemodynamic responses, epinephrine levels in the coronary sinus and systemic circulation, and drug deposition across the ventricular wall, around the circumference and down the axis, were measured. EC delivery via point-source release generated transmural epinephrine gradients directly beneath the site of application extending into the middle third of the myocardial thickness. Gradients in drug deposition were also observed down the length of the heart and around the circumference toward the lateral wall, but not the interventricular septum. These gradients extended further than might be predicted from simple diffusion. The circumferential distribution following local epinephrine delivery from a distributed source to the entire anterior wall drove drug toward the inferior wall, further than with point-source release, but again, not to the septum. This augmented drug distribution away from the release source, down the axis of the left ventricle, and selectively towards the left heart follows the direction of capillary perfusion away from the anterior descending and circumflex arteries, suggesting a role for the coronary circulation in determining local drug deposition and clearance. The dominant role of the coronary vasculature is further suggested by

  6. Assessment of myocardial metabolic flexibility and work efficiency in human type 2 diabetes using 16-[18F]fluoro-4-thiapalmitate, a novel PET fatty acid tracer

    PubMed Central

    Hutchins, G. D.; Perry, K.; Territo, W.; Chisholm, R.; Acton, A.; Glick-Wilson, B.; Considine, R. V.; Moberly, S.; DeGrado, T. R.

    2015-01-01

    Altered myocardial fuel selection likely underlies cardiac disease risk in diabetes, affecting oxygen demand and myocardial metabolic flexibility. We investigated myocardial fuel selection and metabolic flexibility in human type 2 diabetes mellitus (T2DM), using positron emission tomography to measure rates of myocardial fatty acid oxidation {16-[18F]fluoro-4-thia-palmitate (FTP)} and myocardial perfusion and total oxidation ([11C]acetate). Participants underwent paired studies under fasting conditions, comparing 3-h insulin + glucose euglycemic clamp conditions (120 mU·m−2·min−1) to 3-h saline infusion. Lean controls (n = 10) were compared with glycemically controlled volunteers with T2DM (n = 8). Insulin augmented heart rate, blood pressure, and stroke index in both groups (all P < 0.01) and significantly increased myocardial oxygen consumption (P = 0.04) and perfusion (P = 0.01) in both groups. Insulin suppressed available nonesterified fatty acids (P < 0.0001), but fatty acid concentrations were higher in T2DM under both conditions (P < 0.001). Insulin-induced suppression of fatty acid oxidation was seen in both groups (P < 0.0001). However, fatty acid oxidation rates were higher under both conditions in T2DM (P = 0.003). Myocardial work efficiency was lower in T2DM (P = 0.006) and decreased in both groups with the insulin-induced increase in work and shift in fuel utilization (P = 0.01). Augmented fatty acid oxidation is present under baseline and insulin-treated conditions in T2DM, with impaired insulin-induced shifts away from fatty acid oxidation. This is accompanied by reduced work efficiency, possibly due to greater oxygen consumption with fatty acid metabolism. These observations suggest that improved fatty acid suppression, or reductions in myocardial fatty acid uptake and retention, could be therapeutic targets to improve myocardial ischemia tolerance in T2DM. PMID:26732686

  7. Assessment of myocardial metabolic flexibility and work efficiency in human type 2 diabetes using 16-[18F]fluoro-4-thiapalmitate, a novel PET fatty acid tracer.

    PubMed

    Mather, K J; Hutchins, G D; Perry, K; Territo, W; Chisholm, R; Acton, A; Glick-Wilson, B; Considine, R V; Moberly, S; DeGrado, T R

    2016-03-15

    Altered myocardial fuel selection likely underlies cardiac disease risk in diabetes, affecting oxygen demand and myocardial metabolic flexibility. We investigated myocardial fuel selection and metabolic flexibility in human type 2 diabetes mellitus (T2DM), using positron emission tomography to measure rates of myocardial fatty acid oxidation {16-[(18)F]fluoro-4-thia-palmitate (FTP)} and myocardial perfusion and total oxidation ([(11)C]acetate). Participants underwent paired studies under fasting conditions, comparing 3-h insulin + glucose euglycemic clamp conditions (120 mU·m(-2)·min(-1)) to 3-h saline infusion. Lean controls (n = 10) were compared with glycemically controlled volunteers with T2DM (n = 8). Insulin augmented heart rate, blood pressure, and stroke index in both groups (all P < 0.01) and significantly increased myocardial oxygen consumption (P = 0.04) and perfusion (P = 0.01) in both groups. Insulin suppressed available nonesterified fatty acids (P < 0.0001), but fatty acid concentrations were higher in T2DM under both conditions (P < 0.001). Insulin-induced suppression of fatty acid oxidation was seen in both groups (P < 0.0001). However, fatty acid oxidation rates were higher under both conditions in T2DM (P = 0.003). Myocardial work efficiency was lower in T2DM (P = 0.006) and decreased in both groups with the insulin-induced increase in work and shift in fuel utilization (P = 0.01). Augmented fatty acid oxidation is present under baseline and insulin-treated conditions in T2DM, with impaired insulin-induced shifts away from fatty acid oxidation. This is accompanied by reduced work efficiency, possibly due to greater oxygen consumption with fatty acid metabolism. These observations suggest that improved fatty acid suppression, or reductions in myocardial fatty acid uptake and retention, could be therapeutic targets to improve myocardial ischemia tolerance in T2DM. Copyright © 2016 the American Physiological Society.

  8. FAIR exempting separate T (1) measurement (FAIREST): a novel technique for online quantitative perfusion imaging and multi-contrast fMRI.

    PubMed

    Lai, S; Wang, J; Jahng, G H

    2001-01-01

    A new pulse sequence, dubbed FAIR exempting separate T(1) measurement (FAIREST) in which a slice-selective saturation recovery acquisition is added in addition to the standard FAIR (flow-sensitive alternating inversion recovery) scheme, was developed for quantitative perfusion imaging and multi-contrast fMRI. The technique allows for clean separation between and thus simultaneous assessment of BOLD and perfusion effects, whereas quantitative cerebral blood flow (CBF) and tissue T(1) values are monitored online. Online CBF maps were obtained using the FAIREST technique and the measured CBF values were consistent with the off-line CBF maps obtained from using the FAIR technique in combination with a separate sequence for T(1) measurement. Finger tapping activation studies were carried out to demonstrate the applicability of the FAIREST technique in a typical fMRI setting for multi-contrast fMRI. The relative CBF and BOLD changes induced by finger-tapping were 75.1 +/- 18.3 and 1.8 +/- 0.4%, respectively, and the relative oxygen consumption rate change was 2.5 +/- 7.7%. The results from correlation of the T(1) maps with the activation images on a pixel-by-pixel basis show that the mean T(1) value of the CBF activation pixels is close to the T(1) of gray matter while the mean T(1) value of the BOLD activation pixels is close to the T(1) range of blood and cerebrospinal fluid. Copyright 2001 John Wiley & Sons, Ltd.

  9. Improved first-pass spiral myocardial perfusion imaging with variable density trajectories.

    PubMed

    Salerno, Michael; Sica, Christopher; Kramer, Christopher M; Meyer, Craig H

    2013-11-01

    To develop and evaluate variable-density spiral first-pass perfusion pulse sequences for improved efficiency and off-resonance performance and to demonstrate the utility of an apodizing density compensation function (DCF) to improve signal-to-noise ratio (SNR) and reduce dark-rim artifact caused by cardiac motion and Gibbs Ringing. Three variable density spiral trajectories were designed, simulated, and evaluated in 18 normal subjects, and in eight patients with cardiac pathology on a 1.5T scanner. By using a DCF, which intentionally apodizes the k-space data, the sidelobe amplitude of the theoretical point spread function (PSF) is reduced by 68%, with only a 13% increase in the full-width at half-maximum of the main-lobe when compared with the same data corrected with a conventional variable-density DCF, and has an 8% higher resolution than a uniform density spiral with the same number of interleaves and readout duration. Furthermore, this strategy results in a greater than 60% increase in measured SNR when compared with the same variable-density spiral data corrected with a conventional DCF (P < 0.01). Perfusion defects could be clearly visualized with minimal off-resonance and dark-rim artifacts. Variable-density spiral pulse sequences using an apodized DCF produce high-quality first-pass perfusion images with minimal dark-rim and off-resonance artifacts, high SNR and contrast-to-noise ratio, and good delineation of resting perfusion abnormalities. Copyright © 2012 Wiley Periodicals, Inc.

  10. Optimization of a protocol for myocardial perfusion scintigraphy by using an anthropomorphic phantom.

    PubMed

    Ramos, Susie Medeiros Oliveira; Glavam, Adriana Pereira; Kubo, Tadeu Takao Almodovar; de Sá, Lidia Vasconcellos

    2014-01-01

    To develop a study aiming at optimizing myocardial perfusion imaging. Imaging of an anthropomorphic thorax phantom with a GE SPECT Ventri gamma camera, with varied activities and acquisition times, in order to evaluate the influence of these parameters on the quality of the reconstructed medical images. The (99m)Tc-sestamibi radiotracer was utilized, and then the images were clinically evaluated on the basis of data such as summed stress score, and on the technical image quality and perfusion. The software ImageJ was utilized in the data quantification. The results demonstrated that for the standard acquisition time utilized in the procedure (15 seconds per angle), the injected activity could be reduced by 33.34%. Additionally, even if the standard scan time is reduced by 53.34% (7 seconds per angle), the standard injected activity could still be reduced by 16.67%, without impairing the image quality and the diagnostic reliability. The described method and respective results provide a basis for the development of a clinical trial of patients in an optimized protocol.

  11. Optimization of a protocol for myocardial perfusion scintigraphy by using an anthropomorphic phantom*

    PubMed Central

    Ramos, Susie Medeiros Oliveira; Glavam, Adriana Pereira; Kubo, Tadeu Takao Almodovar; de Sá, Lidia Vasconcellos

    2014-01-01

    Objective To develop a study aiming at optimizing myocardial perfusion imaging. Materials and Methods Imaging of an anthropomorphic thorax phantom with a GE SPECT Ventri gamma camera, with varied activities and acquisition times, in order to evaluate the influence of these parameters on the quality of the reconstructed medical images. The 99mTc-sestamibi radiotracer was utilized, and then the images were clinically evaluated on the basis of data such as summed stress score, and on the technical image quality and perfusion. The software ImageJ was utilized in the data quantification. Results The results demonstrated that for the standard acquisition time utilized in the procedure (15 seconds per angle), the injected activity could be reduced by 33.34%. Additionally, even if the standard scan time is reduced by 53.34% (7 seconds per angle), the standard injected activity could still be reduced by 16.67%, without impairing the image quality and the diagnostic reliability. Conclusion The described method and respective results provide a basis for the development of a clinical trial of patients in an optimized protocol. PMID:25741088

  12. The predictive value of 201Tl rest-redistribution and 18F-fluorodeoxyglucose SPECT for wall motion recovery after recent reperfused myocardial infarction.

    PubMed

    González, Patricio; Massardo, Teresa; Coll, Claudia; Humeres, Pamela; Sierralta, Paulina; Jofré, M Josefina; Yovanovich, Jorge; Aramburu, Ivonne; Brugère, Solange; Chamorro, Hernán

    2004-04-01

    201Tl and 18F-FDG are useful for acute myocardial infarction (MI) assessment. The goal of this study was to compare their predictive value for wall motion recovery in the culprit area after a recent reperfused MI using SPECT technique. Forty-one patients (mean age: 56 +/- 12 years) were included, 81% of them male; all were studied within 1-24 days post MI. They underwent angioplasty in 27 cases (12 primary); bypass grafting in 10 cases and successful thrombolysis in 4. SPECT 201Tl injected at rest and redistribution (R-R) and also 18F-FDG, were performed on different days. Processed tomograms were interpreted blinded to clinical or angiographic data. Segmental wall motion assessed with echocardiography at baseline was compared with the 3 month follow up. Sensitivity [Confidence Interval] for 201Tl R-R was 74.6% [60.5-84.5], for FDG it was 82.1% [70.8-90.4]; specificities were 73% [64.3-80.5] and 54.8% [45.6-63.7], respectively. 18F-FDG tended to be more sensitive than 201Tl R-R, but the latter was more specific (p < 0.0004). Both 201Tl RR and 18F-FDG presented high negative predictive value (p: ns). In recent MI, SPECT 201Tl R-R is a valuable and widely available technique for viability detection, with similar sensitivity and significant better specificity than SPECT 18F-FDG.

  13. Coronary Artery Disease: Analysis of Diagnostic Performance of CT Perfusion and MR Perfusion Imaging in Comparison with Quantitative Coronary Angiography and SPECT-Multicenter Prospective Trial.

    PubMed

    Rief, Matthias; Chen, Marcus Y; Vavere, Andrea L; Kendziora, Benjamin; Miller, Julie M; Bandettini, W Patricia; Cox, Christopher; George, Richard T; Lima, João; Di Carli, Marcelo; Plotkin, Michail; Zimmermann, Elke; Laule, Michael; Schlattmann, Peter; Arai, Andrew E; Dewey, Marc

    2018-02-01

    Purpose To compare the diagnostic performance of stress myocardial computed tomography (CT) perfusion with that of stress myocardial magnetic resonance (MR) perfusion imaging in the detection of coronary artery disease (CAD). Materials and Methods All patients gave written informed consent prior to inclusion in this institutional review board-approved study. This two-center substudy of the prospective Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-Detector Row Computed Tomography (CORE320) multicenter trial included 92 patients (mean age, 63.1 years ± 8.1 [standard deviation]; 73% male). All patients underwent perfusion CT and perfusion MR imaging with either adenosine or regadenoson stress. The predefined reference standards were combined quantitative coronary angiography (QCA) and single-photon emission CT (SPECT) or QCA alone. Results from coronary CT angiography were not included, and diagnostic performance was evaluated with the Mantel-Haenszel test stratified by disease status. Results The prevalence of CAD was 39% (36 of 92) according to QCA and SPECT and 64% (59 of 92) according to QCA alone. When compared with QCA and SPECT, per-patient diagnostic accuracy of perfusion CT and perfusion MR imaging was 63% (58 of 92) and 75% (69 of 92), respectively (P = .11); sensitivity was 92% (33 of 36) and 83% (30 of 36), respectively (P = .45); and specificity was 45% (25 of 56) and 70% (39 of 56), respectively (P < .01). When compared with QCA alone, diagnostic accuracy of CT perfusion and MR perfusion imaging was 82% (75 of 92) and 74% (68 of 92), respectively (P = .27); sensitivity was 90% (53 of 59) and 69% (41 of 59), respectively (P < .01); and specificity was 67% (22 of 33) and 82% (27 of 33), respectively (P = .27). Conclusion This multicenter study shows that the diagnostic performance of perfusion CT is similar to that of perfusion MR imaging in the detection of CAD. © RSNA, 2017 Online supplemental material is

  14. Novel synthesis and initial preclinical evaluation of (18)F-[FDG] labeled rhodamine: a potential PET myocardial perfusion imaging agent.

    PubMed

    AlJammaz, Ibrahim; Al-Otaibi, Basim; AlHindas, Hussein; Okarvi, Subhani M

    2015-10-01

    Myocardial perfusion imaging is one of the most commonly performed investigations in nuclear medicine studies. Due to the clinical importance of [(18)F]-fluoro-2-deoxy-D-glucose ([(18)F]-FDG) and its availability in almost every PET center, a new radiofluorinated [(18)F]-FDG-rhodamine conjugate was synthesized using [(18)F]-FDG as a prosthetic group. In a convenient and simple one-step radiosynthesis, [(18)F]-FDG-rhodamine conjugate was prepared in quantitative radiochemical yields, with total synthesis time of nearly 20 min and radiochemical purity of greater than 98%, without the need for HPLC purification, which make these approaches amenable for automation. Biodistribution studies in normal rats at 60 min post-injection demonstrated a high uptake in the heart (>11% ID/g) and favorable pharmacokinetics. Additionally, [(18)F]-FDG-rhodamine showed an extraction value of 27.63%±5.12% in rat hearts. These results demonstrate that [(18)F]-FDG-rhodamine conjugate may be useful as an imaging agent for the positron emission tomography evaluation of myocardial perfusion. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Increased Regional Epicardial Fat Volume Associated with Reversible Myocardial Ischemia in Patients with Suspected Coronary Artery Disease

    PubMed Central

    Khawaja, Tuba; Greer, Christine; Thadani, Samir R.; Kato, Tomoko S.; Bhatia, Ketan; Shimbo, Daichi; Konkak, Andrew; Bokhari, Sabahat; Einstein, Andrew J.; Schulze, P. Christian

    2015-01-01

    Epicardial adipose tissue is a source of pro-inflammatory cytokines and has been linked to the development of coronary artery disease. No study has systematically assessed the relationship between local epicardial fat volume (EFV) and myocardial perfusion defects. We analyzed EFV in patients undergoing SPECT myocardial perfusion imaging combined with computed tomography (CT) for attenuation correction. Low-dose CT without contrast was performed in 396 consecutive patients undergoing SPECT imaging for evaluation of coronary artery disease. Regional thickness, cross-sectional areas, and total EFV were assessed. 295 patients had normal myocardial perfusion scans and 101 had abnormal perfusion scans. Mean EFVs in normal, ischemic, and infarcted hearts were 99.8 ± 82.3 cm3, 156.4 ± 121.9 cm3, and 96.3 ± 102.1 cm3, respectively (P < 0.001). Reversible perfusion defects were associated with increased local EFV compared to normal perfusion in the distribution of the right (69.2 ± 51.5 vs 46.6 ± 32.0 cm3; P = 0.03) and left anterior descending coronary artery (87.1 ± 76.4 vs 46.7 ± 40.6 cm3; P = 0.005). Our results demonstrate increased regional epicardial fat in patients with active myocardial ischemia compared to patients with myocardial scar or normal perfusion on nuclear perfusion scans. Our results suggest a potential role for cardiac CT to improve risk stratification in patients with suspected coronary artery disease. PMID:25339129

  16. Comparative utility of gated myocardial perfusion imaging and transthoracic coronary flow reserve for the assessment of coronary artery disease in patients with left bundle branch block.

    PubMed

    Pavlovic, Smiljana; Sobic-Saranovic, Dragana; Djordjevic-Dikic, Ana; Beleslin, Branko; Stepanovic, Jelena; Artiko, Vera; Giga, Vojislav; Petrasinovic, Zorica; Ostojic, Miodrag; Vujisic-Tesic, Bosiljka; Obradovic, Vladimir

    2010-04-01

    To compare the diagnostic utility of gated single-photon emission computed tomography (SPECT) methoxy isobutyl isonitrile (MIBI) myocardial perfusion imaging and transthoracic Doppler echocardiography (TTDE) coronary flow reserve (CFR) to coronary angiography for detecting coronary artery disease (CAD) in patients with left bundle branch block (LBBB). Forty-three patients with complete LBBB and an intermediate pretest probability for CAD underwent dipyridamole stress TTDE and gated SPECT MIBI during the same session and coronary angiography within a month. The parameters of myocardial perfusion (summed stress score, summed difference scores) regional wall function (wall motion score, wall thickening score) and ejection fraction were derived using the 17-segment model and 4D-MSPECT software. TTDE variables included peak flow velocity at rest and during hyperemia in left anterior descending artery (LAD), based on which CFR was calculated (normal>2). Perfusion ischemic scores were significantly higher in group 1 with angiographic evidence of greater than 50% LAD stenosis compared with group 2 with less than 50% LAD stenosis (summed stress score 12.4+/-5.5 vs. 8.3+/-3.5, P<0.05, summed difference score 3.7+/-1.2 vs. 1.1+/-0.3, P<0.01, respectively). Left ventricular regional wall function and ejection fraction were not different between the two groups. CFR was significantly lower in group 1 than in group 2 (1.65+/-0.21 vs. 2.31+/-0.28, P<0.001). Gated SPECT MIBI and CFR had similar sensitivity (88 vs. 88%), specificity (80 vs. 84%), and accuracy (84 vs. 86%) for detecting CAD in patients with LBBB. The agreement between the two methods was 85%. Our results show comparable diagnostic utility and high agreement between gated SPECT MIBI perfusion imaging and TTDE CFR assessment for detecting CAD in patients with LBBB. The advantage of gated SPECT MIBI over TTDE CFR measurements is the ability to assess the perfusion abnormalities in multiple vascular territories during

  17. Development and Evaluation of Heartbeat: A Machine Perfusion Heart Preservation System.

    PubMed

    Li, Yongnan; Zeng, Qingdong; Liu, Gang; Du, Junzhe; Gao, Bingren; Wang, Wei; Zheng, Zhe; Hu, Shengshou; Ji, Bingyang

    2017-11-01

    Static cold storage is accompanied with a partial safe ischemic interval for donor hearts. In this current study, a machine perfusion system was built to provide a better preservation for the donor heart and assessment for myocardial function. Chinese mini-swine (weight 30-35 kg, n = 16) were randomly divided into HTK, Celsior, and Heartbeat groups. All donor hearts were respectively preserved for 8 hours under static cold storage or machine perfusion. The perfusion solution is aimed to maintain its homeostasis based on monitoring the Heartbeat group. The ultrastructure of myocardium suggests better myocardial protection in the Heartbeat group compared with HTK or Celsior-preserved hearts. The myocardial and coronary artery structural and functional integrity was evaluated by immunofluorescence and Western blots in the Heartbeat. In the Heartbeat group, donor hearts maintained a high adenosine triphosphate level. Bcl-2 and Beclin-1 protein demonstrates high expression in the Celsior group. The Heartbeat system can be used to preserve donor hearts, and it could guarantee the myocardial and endothelial function of hearts during machine perfusion. Translating Heartbeat into clinical practice, it is such as to impact on donor heart preservation for cardiac transplantation. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  18. Myocardial contrast echocardiography in mice: technical and physiological aspects.

    PubMed

    Verkaik, Melissa; van Poelgeest, Erik M; Kwekkeboom, Rick F J; Ter Wee, Piet M; van den Brom, Charissa E; Vervloet, Marc G; Eringa, Etto C

    2018-03-01

    Myocardial contrast echocardiography (MCE) offers the opportunity to study myocardial perfusion defects in mice in detail. The value of MCE compared with single-photon emission computed tomography, positron emission tomography, and computed tomography consists of high spatial resolution, the possibility of quantification of blood volume, and relatively low costs. Nevertheless, a number of technical and physiological aspects should be considered to ensure reproducibility among research groups. The aim of this overview is to describe technical aspects of MCE and the physiological parameters that influence myocardial perfusion data obtained with this technique. First, technical aspects of MCE discussed in this technical review are logarithmic compression of ultrasound data by ultrasound systems, saturation of the contrast signal, and acquisition of images during different phases of the cardiac cycle. Second, physiological aspects of myocardial perfusion that are affected by the experimental design are discussed, including the anesthesia regimen, systemic cardiovascular effects of vasoactive agents used, and fluctuations in body temperature that alter myocardial perfusion. When these technical and physiological aspects of MCE are taken into account and adequately standardized, MCE is an easily accessible technique for mice that can be used to study the control of myocardial perfusion by a wide range of factors.

  19. [Hypertrophic cardiomyopathy showing no 123I-BMIPP myocardial accumulation with type I CD36 deficiency].

    PubMed

    Watanabe, K; Miyajima, S; Kusano, Y; Tanabe, N; Hirokawa, Y

    1997-07-01

    A 57 years old male consulted our hospital in complaining chest oppression and short of breath. Familial and dilated phase hypertrophic cardiomyopathy (HCM) was detected by ECG, echocardiography, left ventriculography and left ventricular endomyocardial biopsy. 201T1 SPECT showed regional increased accumulation in the ventricular septum, however, no myocardial accumulation of 123I-beta-methyl-p-iodophenylpentadecanoic acid (123I-BMIPP) was observed. We analyzed CD36 in this patient, and found he had type 1 CD36 deficiency. Myocardial uptake of long-chain fatty acids occurs via a specific transporter, which is homologous with human CD36. We hypothesize that CD36 deficiency, especially type 1 CD36 deficiency, might be one factor of no myocardial 123I-BMIPP uptake.

  20. Prognostic validation of a 17-segment score derived from a 20-segment score for myocardial perfusion SPECT interpretation.

    PubMed

    Berman, Daniel S; Abidov, Aiden; Kang, Xingping; Hayes, Sean W; Friedman, John D; Sciammarella, Maria G; Cohen, Ishac; Gerlach, James; Waechter, Parker B; Germano, Guido; Hachamovitch, Rory

    2004-01-01

    Recently, a 17-segment model of the left ventricle has been recommended as an optimally weighted approach for interpreting myocardial perfusion single photon emission computed tomography (SPECT). Methods to convert databases from previous 20- to new 17-segment data and criteria for abnormality for the 17-segment scores are needed. Initially, for derivation of the conversion algorithm, 65 patients were studied (algorithm population) (pilot group, n = 28; validation group, n = 37). Three conversion algorithms were derived: algorithm 1, which used mid, distal, and apical scores; algorithm 2, which used distal and apical scores alone; and algorithm 3, which used maximal scores of the distal septal, lateral, and apical segments in the 20-segment model for 3 corresponding segments of the 17-segment model. The prognosis population comprised 16,020 consecutive patients (mean age, 65 +/- 12 years; 41% women) who had exercise or vasodilator stress technetium 99m sestamibi myocardial perfusion SPECT and were followed up for 2.1 +/- 0.8 years. In this population, 17-segment scores were derived from 20-segment scores by use of algorithm 2, which demonstrated the best agreement with expert 17-segment reading in the algorithm population. The prognostic value of the 20- and 17-segment scores was compared by converting the respective summed scores into percent myocardium abnormal. Conversion algorithm 2 was found to be highly concordant with expert visual analysis by the 17-segment model (r = 0.982; kappa = 0.866) in the algorithm population. In the prognosis population, 456 cardiac deaths occurred during follow-up. When the conversion algorithm was applied, extent and severity of perfusion defects were nearly identical by 20- and derived 17-segment scores. The receiver operating characteristic curve areas by 20- and 17-segment perfusion scores were identical for predicting cardiac death (both 0.77 +/- 0.02, P = not significant). The optimal prognostic cutoff value for either 20

  1. Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR

    NASA Astrophysics Data System (ADS)

    Petibon, Yoann; Guehl, Nicolas J.; Reese, Timothy G.; Ebrahimi, Behzad; Normandin, Marc D.; Shoup, Timothy M.; Alpert, Nathaniel M.; El Fakhri, Georges; Ouyang, Jinsong

    2017-01-01

    PET is an established modality for myocardial perfusion imaging (MPI) which enables quantification of absolute myocardial blood flow (MBF) using dynamic imaging and kinetic modeling. However, heart motion and partial volume effects (PVE) significantly limit the spatial resolution and quantitative accuracy of PET MPI. Simultaneous PET-MR offers a solution to the motion problem in PET by enabling MR-based motion correction of PET data. The aim of this study was to develop a motion and PVE correction methodology for PET MPI using simultaneous PET-MR, and to assess its impact on both static and dynamic PET MPI using 18F-Flurpiridaz, a novel 18F-labeled perfusion tracer. Two dynamic 18F-Flurpiridaz MPI scans were performed on healthy pigs using a PET-MR scanner. Cardiac motion was tracked using a dedicated tagged-MRI (tMR) sequence. Motion fields were estimated using non-rigid registration of tMR images and used to calculate motion-dependent attenuation maps. Motion correction of PET data was achieved by incorporating tMR-based motion fields and motion-dependent attenuation coefficients into image reconstruction. Dynamic and static PET datasets were created for each scan. Each dataset was reconstructed as (i) Ungated, (ii) Gated (end-diastolic phase), and (iii) Motion-Corrected (MoCo), each without and with point spread function (PSF) modeling for PVE correction. Myocardium-to-blood concentration ratios (MBR) and apparent wall thickness were calculated to assess image quality for static MPI. For dynamic MPI, segment- and voxel-wise MBF values were estimated by non-linear fitting of a 2-tissue compartment model to tissue time-activity-curves. MoCo and Gating respectively decreased mean apparent wall thickness by 15.1% and 14.4% and increased MBR by 20.3% and 13.6% compared to Ungated images (P  <  0.01). Combined motion and PSF correction (MoCo-PSF) yielded 30.9% (15.7%) lower wall thickness and 82.2% (20.5%) higher MBR compared to Ungated data reconstructed

  2. Pharmacological stress myocardial perfusion imaging with the potent and selective A(2A) adenosine receptor agonists ATL193 and ATL146e administered by either intravenous infusion or bolus injection.

    PubMed

    Glover, D K; Ruiz, M; Takehana, K; Petruzella, F D; Riou, L M; Rieger, J M; Macdonald, T L; Watson, D D; Linden, J; Beller, G A

    2001-09-04

    Adenosine (Ado) and dipyridamole are alternatives to exercise stress for myocardial perfusion imaging. Though generally safe, side effects frequently occur that cause patient discomfort and sometimes lead to premature termination of the study or require aminophylline administration. Recently, a new class of A(2A) Ado receptor agonists was synthesized. ATL193 and ATL146e are 2-propynylcyclohexyl-5'-N-ethylcarboxamido derivatives of Ado. The study goals were to evaluate the potency and selectivity of these new compounds on recombinant canine Ado receptors and to evaluate their hemodynamic properties in dogs to assess their usefulness as vasodilators for myocardial perfusion imaging. In assays of recombinant canine Ado receptors, ATL-193 and ATL-146e were highly selective for the A(2A) over the A(1) and A(3) receptors and were more potent than MRE-0470 and CGS-21680. In 16 anesthetized dogs, the agonists were administered by infusion (ATL-193; n=7 normal) or bolus injection (ATL-146e; n=9 critical left anterior descending coronary artery stenosis), and hemodynamic responses were compared with those of Ado. Both agonists produced dose-dependent coronary flow (CF) elevation without provoking the hypotension observed with Ado. After an ATL-146e bolus, the CF increase was sustained for several minutes, providing ample time for injection and myocardial uptake of (99m)Tc-sestamibi, and CF returned to baseline within 20 minutes. The CF increase was completely blocked by the selective A(2A) antagonist ZM241385 (3 microgram. kg(-1). min(-1)). ATL-193 and ATL-146e are highly potent and selective Ado A(2A) receptor agonists with excellent potential for use as vasodilators for myocardial perfusion imaging. An important advantage of ATL-146e is the ability to administer it by bolus injection.

  3. Myocardial Blood Volume Is Associated with Myocardial Oxygen Consumption: An Experimental Study with CMR in a Canine Model

    PubMed Central

    McCommis, Kyle S.; Zhang, Haosen; Goldstein, Thomas A.; Misselwitz, Bernd; Abendschein, Dana R.; Gropler, Robert J.; Zheng, Jie

    2009-01-01

    OBJECTIVES To evaluate the feasibility of cardiovascular MR (CMR) to determine regional myocardial perfusion and O2 metabolism, and assess the role of myocardial blood volume (MBV) on oxygen supply. BACKGROUND Coronary artery disease presents as an imbalance of myocardial oxygen supply and demand. We have developed relevant CMR methods to determine the relationship of myocardial blood flow (MBF) and MBV to oxygen consumption (MVO2) during pharmacologic hyperemia. METHODS Twenty-one mongrel dogs were studied with varying stenosis severities imposed on the proximal left anterior descending (LAD) coronary artery. MBF and MBV were determined by CMR first-pass perfusion, while the oxygen extraction fraction (OEF) and MVO2 were determined by the myocardial Blood-Oxygen-Level-Dependent (BOLD) effect and Fick’s law, respectively. MR imaging was performed at rest, and during either dipyridamole-induced vasodilation or dobutamine-induced hyperemia. Regional differences in myocardial perfusion and oxygenation were then evaluated. RESULTS Dipyridamole and dobutamine both led to 145–200% increases in MBF and 50–80% increases in MBV in normal perfused myocardium. As expected, MVO2 increased more significantly with dobutamine (~175%) than dipyridamole (~40%). Coronary stenosis resulted in an attenuation of MBF, MBV, and MVO2 in both the LAD-subtended stenosis region and the left circumflex subtended remote region. Liner regression analysis showed that MBV reserve appears to be more correlated with MVO2 reserve during dobutamine stress than MBF reserve, particularly in the stenotic regions. Conversely, MBF reserve appears to be more correlated with MVO2 reserve during dipyridamole, although neither of these differences was significant. CONCLUSIONS Noninvasive evaluation of both myocardial perfusion and oxygenation by CMR facilitates direct monitoring of regional myocardial ischemia and provides a valuable tool for better understanding microvascular pathophysiology. These

  4. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in-vivo studies

    PubMed Central

    Petibon, Yoann; Rakvongthai, Yothin; Fakhri, Georges El; Ouyang, Jinsong

    2017-01-01

    Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves -TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in-vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans - each containing 1/8th of the total number of events - were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard Ordered Subset Expectation Maximization (OSEM) reconstruction algorithm on one side, and the One-Step Late Maximum a Posteriori (OSL-MAP) algorithm on the other

  5. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies

    NASA Astrophysics Data System (ADS)

    Petibon, Yoann; Rakvongthai, Yothin; El Fakhri, Georges; Ouyang, Jinsong

    2017-05-01

    Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans—each containing 1/8th of the total number of events—were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other

  6. Early detection of radiation-induced heart disease using (99m)Tc-MIBI SPECT gated myocardial perfusion imaging in patients with oesophageal cancer during radiotherapy.

    PubMed

    Zhang, Peng; Hu, Xudong; Yue, Jinbo; Meng, Xue; Han, Dali; Sun, Xindong; Yang, Guoren; Wang, Shijiang; Wang, Xiaohui; Yu, Jinming

    2015-05-01

    The primary aim of this prospective study was to investigate the value of (99m)Tc-methoxyisobutylisonitrile (MIBI) single photon emission computed tomography (SPECT) gated myocardial perfusion imaging (GMPI) in the detection of radiation-induced heart disease (RIHD) as early as during radiotherapy (RT) for oesophageal cancer (EC). The second aim was to analyse the correlation between cardiac toxicity and the dose-volume factors. The (99m)Tc-MIBI SPECT GMPI was performed both pre-RT and during RT (40Gray). The results of the SPECT were quantitatively analysed with QGS/QPS software and read by two experienced nuclear medicine physicians. The correlation between the changes in the SPECT parameters and the RT dosimetric data was analysed. Eighteen patients with locally advanced EC were enrolled in the study. Compared with the baseline, the imaging during RT showed not only significant decreases in the wall motion (WM) (1/20 segments), wall thickening (WT) (2/20 segments), end-diastolic perfusion (EDP) (5/20 segments) and end-systolic perfusion (ESP) (8/20 segments) (p<0.05) but also a significant increase in the heart rate (74.63±7.79 vs 81.49±9.90, p=0.036). New myocardial perfusion defects were observed in 8 of the 18 patients. The V37-V40 was significantly higher (p<0.05) in the patients with the new perfusion defects during RT than in the patients who did not exhibit these defects. Radiotherapy for EC induces cardiac damage from an early stage. (99m)Tc-MIBI SPECT GMPI can detect the occurrence of cardiac impairment during RT. The WM, WT, EDP and ESP may be valuable as early indicators of RIHD. The percentage of the heart volume that receives a high dose is an important factor that is correlated with RIHD. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. Myocardial aging as a T-cell–mediated phenomenon

    PubMed Central

    Ramos, Gustavo Campos; van den Berg, Anne; Nunes-Silva, Vânia; Weirather, Johannes; Peters, Laura; Burkard, Matthias; Friedrich, Mike; Pinnecker, Jürgen; Abeßer, Marco; Heinze, Katrin G.; Schuh, Kai; Beyersdorf, Niklas; Kerkau, Thomas; Demengeot, Jocelyne; Frantz, Stefan; Hofmann, Ulrich

    2017-01-01

    In recent years, the myocardium has been rediscovered under the lenses of immunology, and lymphocytes have been implicated in the pathogenesis of cardiomyopathies with different etiologies. Aging is an important risk factor for heart diseases, and it also has impact on the immune system. Thus, we sought to determine whether immunological activity would influence myocardial structure and function in elderly mice. Morphological, functional, and molecular analyses revealed that the age-related myocardial impairment occurs in parallel with shifts in the composition of tissue-resident leukocytes and with an accumulation of activated CD4+ Foxp3− (forkhead box P3) IFN-γ+ T cells in the heart-draining lymph nodes. A comprehensive characterization of different aged immune-deficient mouse strains revealed that T cells significantly contribute to age-related myocardial inflammation and functional decline. Upon adoptive cell transfer, the T cells isolated from the mediastinal lymph node (med-LN) of aged animals exhibited increased cardiotropism, compared with cells purified from young donors or from other irrelevant sites. Nevertheless, these cells caused rather mild effects on cardiac functionality, indicating that myocardial aging might stem from a combination of intrinsic and extrinsic (immunological) factors. Taken together, the data herein presented indicate that heart-directed immune responses may spontaneously arise in the elderly, even in the absence of a clear tissue damage or concomitant infection. These observations might shed new light on the emerging role of T cells in myocardial diseases, which primarily affect the elderly population. PMID:28255084

  8. Myocardial strain in healthy adults across a broad age range as revealed by cardiac magnetic resonance imaging at 1.5 and 3.0T: Associations of myocardial strain with myocardial region, age, and sex.

    PubMed

    Mangion, Kenneth; Clerfond, Guillaume; McComb, Christie; Carrick, David; Rauhalammi, Samuli M; McClure, John; Corcoran, David S; Woodward, Rosemary; Orchard, Vanessa; Radjenovic, Aleksandra; Zhong, Xiaodong; Berry, Colin

    2016-11-01

    To assess myocardial strain using cine displacement encoding with stimulated echoes (DENSE) using 1.5T and 3.0T MRI in healthy adults. Healthy adults without any history of cardiovascular disease underwent magnetic resonance imaging (MRI) at 1.5T and 3.0T within 2 days. The MRI protocol included balanced steady-state free-precession (b-SSFP), 2D cine-echo planar imaging (EPI)-DENSE, and late gadolinium enhancement in subjects >45 years. Acquisitions were divided into six segments; global and segmental peak longitudinal and circumferential strain were derived and analyzed by field strength, age, and gender. In all, 89 volunteers (mean age 44.8 ± 18.0 years, range: 18-87 years) underwent MRI at 1.5T, and 88 of these subjects underwent MRI at 3.0T (1.4 ± 1.4 days between the scans). Compared with 3.0T, the magnitudes of global circumferential (-19.5 ± 2.6% vs. -18.47 ± 2.6%; P = 0.001) and longitudinal (-12.47 ± 3.2% vs. -10.53 ± 3.1%; P = 0.004) strain were greater at 1.5T. At 1.5T, longitudinal strain was greater in females than in males: -10.17 ± 3.4% vs. -13.67 ± 2.4%; P = 0.001. Similar observations occurred for circumferential strain at 1.5T (-18.72 ± 2.2% vs. -20.10 ± 2.7%; P = 0.014) and at 3.0T (-17.92 ± 1.8% vs. -19.1 ± 3.1%; P = 0.047). At 1.5T, longitudinal and circumferential strain were not associated with age after accounting for sex (longitudinal strain P = 0.178, circumferential strain P = 0.733). At 3.0T, longitudinal and circumferential strain were associated with age (P < 0.05). Longitudinal strain values were greater in the apico-septal, basal-lateral, and mid-lateral segments and circumferential strain in the inferior, infero-lateral, and antero-lateral LV segments. Myocardial strain parameters as revealed by cine-DENSE at different MRI field strengths were associated with myocardial region, age, and sex. J. Magn. Reson. Imaging 2016;44:1197-1205. © 2016 The Authors Journal of Magnetic Resonance Imaging published by Wiley Periodicals

  9. Prognostic implications of atrial fibrillation in patients undergoing myocardial perfusion single-photon emission computed tomography.

    PubMed

    Abidov, Aiden; Hachamovitch, Rory; Rozanski, Alan; Hayes, Sean W; Santos, Marcia M; Sciammarella, Maria G; Cohen, Ishac; Gerlach, James; Friedman, John D; Germano, Guido; Berman, Daniel S

    2004-09-01

    The aim of this research was to determine whether presence of atrial fibrillation (AF) provides incremental prognostic information relative to myocardial perfusion single-photon emission computed tomography (MPS) with respect to risk of cardiac death (CD). The prognostic significance of AF in patients undergoing MPS is not known. A total of 16,048 consecutive patients undergoing MPS were followed-up for a mean of 2.21 +/- 1.15 years for the development of CD. Of those, 384 patients (2.4%) had AF. Cox proportional hazards method was used to compare clinical and perfusion data for the prediction of CD in patients with and without AF. Atrial fibrillation was a significant predictor of CD in patients with normal (1.6% per year vs. 0.4% per year in non-AF patients), mildly abnormal (6.3% per year vs. 1.2% per year), and severely abnormal MPS (6.4% per year vs. 3.7% per year) (p < 0.001 for all). By multivariable analysis, AF patients had worse survival (p = 0.001) even after adjustment for the variables most predictive of CD: age, diabetes, shortness of breath, use of vasodilator stress, rest heart rate, and the nuclear variables. In the 4,239 patients with left ventricular ejection fraction evaluated by gated MPS, AF demonstrated incremental prognostic value not only over clinical and nuclear variables, but also over left ventricular ejection in predicting CD (p = 0.014). The presence of AF independently increases the risk of cardiac events over perfusion and function variables in patients undergoing MPS. Patients with AF have a high risk of CD, even when MPS is only mildly abnormal. Whether patients with AF and mildly abnormal MPS constitute a group more deserving of early referral to cardiac catheterization is a question warranting further study.

  10. Predictive value of myocardial perfusion single-photon emission computed tomography and the impact of renal function on cardiac death.

    PubMed

    Hakeem, Abdul; Bhatti, Sabha; Dillie, Kathryn Sullivan; Cook, Jeffrey R; Samad, Zainab; Roth-Cline, Michelle D; Chang, Su Min

    2008-12-09

    Patients with chronic kidney disease (CKD) have worse cardiovascular outcomes than those without CKD. The prognostic utility of myocardial perfusion single-photon emission CT (MPS) in patients with varying degrees of renal dysfunction and the impact of CKD on cardiac death prediction in patients undergoing MPS have not been investigated. We followed up 1652 consecutive patients who underwent stress MPS (32% exercise, 95% gated) for cardiac death for a mean of 2.15+/-0.8 years. MPS defects were defined with a summed stress score (normal summed stress score <4, abnormal summed stress score>or=4). Ischemia was defined as a summed stress score >or=4 plus a summed difference score >or=2, and scar was defined as a summed difference score <2 plus a summed stress score >or=4. Renal function was calculated with the Modified Diet in Renal Disease equation. CKD (estimated glomerular filtration rate <60 mL . min(-1) . 1.73 m(-2)) was present in 36%. Cardiac death increased with worsening levels of perfusion defects across the entire spectrum of renal function. Presence of ischemia was independently predictive of cardiac death, all-cause mortality, and nonfatal myocardial infarction. Patients with normal MPS and CKD had higher unadjusted cardiac death event rates than those with no CKD and normal MPS (2.7% versus 0.8%, P=0.001). Multivariate Cox proportional hazards models revealed that both perfusion defects (hazard ratio 1.90, 95% CI 1.47 to 2.46) and CKD (hazard ratio 1.96, 95% CI 1.29 to 2.95) were independent predictors of cardiac death after accounting for risk factors, left ventricular dysfunction, pharmacological stress, and symptom status. Both MPS and CKD had incremental power for cardiac death prediction over baseline risk factors and left ventricular dysfunction (global chi(2) 207.5 versus 169.3, P<0.0001). MPS provides effective risk stratification across the entire spectrum of renal function. Renal dysfunction is also an important independent predictor of cardiac

  11. Accelerated Dual-contrast First-pass Perfusion MRI of the Mouse Heart: Development and Application to Diet-induced Obese Mice

    PubMed Central

    Naresh, Nivedita K.; Chen, Xiao; Roy, Rene J.; Antkowiak, Patrick F.; Annex, Brian H.; Epstein, Frederick H.

    2014-01-01

    Background Gene-modified mice may be used to elucidate molecular mechanisms underlying abnormal myocardial blood flow (MBF). We sought to develop a quantitative myocardial perfusion imaging technique for mice and to test the hypothesis that myocardial perfusion reserve (MPR) is reduced in a mouse model of diet-induced obesity (DIO). Methods A dual-contrast saturation-recovery sequence with ky-t undersampling and a motion-compensated compressed sensing reconstruction algorithm was developed for first-pass MRI on a small-bore 7T system. Control mice were imaged at rest and with the vasodilators ATL313 and Regadenoson (n=6 each). In addition, we imaged mice fed a high-fat diet (HFD) for 24 weeks. Results In control mice, MBF was 5.7±0.8 ml/g/min at rest and it increased to 11.8±0.6 ml/g/min with ATL313 and to 10.4±0.3 ml/g/min with Regadenoson. In HFD mice we detected normal resting MBF (5.6±0.4 vs. 5.0±0.3 on control diet), low MBF at stress (7.7±0.4 vs. 10.4±0.3 on control diet, p<0.05), and reduced MPR (1.4±0.2 vs. 2.0±0.3 on control diet, p<0.05). Conclusions Accelerated dual-contrast first-pass MRI with motion-compensated compressed sensing provides spatiotemporal resolution suitable for measuring MBF in free-breathing mice, and detected reduced MPR in DIO mice. These techniques may be used to study molecular mechanisms that underlie abnormal myocardial perfusion. PMID:24760707

  12. Cardiac CT for myocardial ischaemia detection and characterization--comparative analysis.

    PubMed

    Bucher, A M; De Cecco, C N; Schoepf, U J; Wang, R; Meinel, F G; Binukrishnan, S R; Spearman, J V; Vogl, T J; Ruzsics, B

    2014-11-01

    The assessment of patients presenting with symptoms of myocardial ischaemia remains one of the most common and challenging clinical scenarios faced by physicians. Current imaging modalities are capable of three-dimensional, functional and anatomical views of the heart and as such offer a unique contribution to understanding and managing the pathology involved. Evidence has accumulated that visual anatomical coronary evaluation does not adequately predict haemodynamic relevance and should be complemented by physiological evaluation, highlighting the importance of functional assessment. Technical advances in CT technology over the past decade have progressively moved cardiac CT imaging into the clinical workflow. In addition to anatomical evaluation, cardiac CT is capable of providing myocardial perfusion parameters. A variety of CT techniques can be used to assess the myocardial perfusion. The single energy first-pass CT and dual energy first-pass CT allow static assessment of myocardial blood pool. Dynamic cardiac CT imaging allows quantification of myocardial perfusion through time-resolved attenuation data. CT-based myocardial perfusion imaging (MPI) is showing promising diagnostic accuracy compared with the current reference modalities. The aim of this review is to present currently available myocardial perfusion techniques with a focus on CT imaging in light of recent clinical investigations. This article provides a comprehensive overview of currently available CT approaches of static and dynamic MPI and presents the results of corresponding clinical trials.

  13. Cardiovascular magnetic resonance profiling of coronary atherosclerosis: vessel wall remodelling and related myocardial blood flow alterations.

    PubMed

    Jahnke, Cosima; Manka, Robert; Kozerke, Sebastian; Schnackenburg, Bernhard; Gebker, Rolf; Marx, Nikolaus; Paetsch, Ingo

    2014-12-01

    To determine the association between coronary vessel wall morphology and haemodynamic consequences to the myocardium using a combined cardiovascular magnetic resonance (CMR) imaging protocol. Non-invasive CMR profiling of coronary atherosclerotic wall changes and related myocardial blood flow impairment has not been established yet. Sixty-three patients (45 men, 61.5 ± 10.7 years) with suspected or known coronary artery disease underwent 3.0 Tesla CMR imaging. The combined CMR protocol consisted of the following imaging modules at rest: 3D vessel wall imaging and flow measurement of the proximal right coronary artery (RCA), myocardial T2*, and first-pass perfusion imaging. During adenosine stress coronary flow, T2* and first-pass perfusion imaging were repeated. Coronary X-ray angiography classified patient groups: (i) all-smooth (n = 19); (ii) luminal irregular (diameter reduction < 30%; n = 35); and (iii) stenosed RCA (diameter reduction ≥ 50%; n = 9). The ratio of CMR-derived vessel wall area-to-lumen area significantly increased stepwise for the comparison of all-smooth vs. luminal irregular vs. stenosed RCA (1.9 ± 0.6 vs. 2.6 ± 0.6 vs. 3.6 ± 0.9, P < 0.01). Epicardial coronary flow reserve exhibited a stepwise significant decrease (3.4 ± 0.5 vs. 2.9 ± 0.7 vs. 1.7 ± 0.3, P < 0.01). On the myocardial level, stress-induced percentage gain of T2* values (ΔT2*) was significantly decreased between groups (29.2 ± 10.6 vs. 9.0 ± 9.8 vs. 2.2 ± 11.8%, P < 0.01) while perfusion reserve index decreased in the presence of stenosed RCA only (2.2 ± 0.6 vs. 2.0 ± 0.4 vs. 1.3 ± 0.3, P = ns and P < 0.01, respectively). The proposed comprehensive CMR imaging protocol provided a non-invasive approach for direct assessment of coronary vessel wall remodelling and resultant pathophysiological consequences on the level of epicardial coronary and myocardial blood flow in patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The

  14. Cardiac T1 mapping in congenital heart disease: bolus vs. infusion protocols for measurements of myocardial extracellular volume fraction.

    PubMed

    Al-Wakeel-Marquard, Nadya; Rastin, Sanaz; Muench, Frédéric; O H-Ici, Darach; Yilmaz, Sevim; Berger, Felix; Kuehne, Titus; Messroghli, Daniel R

    2017-12-01

    Myocardial extracellular volume fraction (ECV) reflecting diffuse myocardial fibrosis can be measured with T1 mapping cardiovascular magnetic resonance (CMR) before and after the application of a gadolinium-based extracellular contrast agent. The equilibrium between blood and myocardium contrast concentration required for ECV measurements can be obtained with a primed contrast infusion (equilibrium contrast-CMR). We hypothesized that equilibrium can also be achieved with a single contrast bolus to accurately measure diffuse myocardial fibrosis in patients with congenital heart disease (CHD). Healthy controls (n = 17; median age 24.0 years) and patients with CHD (n = 19; 25.0 years) were prospectively enrolled. Using modified Look-Locker inversion recovery T1 mapping before, 15 min after bolus injection, and during constant infusion of gadolinium-DOTA, T1 values were obtained for blood pool and myocardium of the left ventricle (LV), the interventricular septum (IVS), and the right ventricle (RV) in a single midventricular plane in short axis or in transverse orientation. ECV of LV, IVS and RV by bolus-only and bolus-infusion correlated significantly in CHD patients (r = 0.94, 0.95, and 0.74; p < 0.01, respectively) and healthy controls (r = 0.96, 0.89, and 0.64; p < 0.05, respectively). Bland-Altman plots revealed no significant bias between the techniques for any of the analyzed regions. ECV of LV and RV myocardium measured by bolus-only T1 mapping agrees well with bolus-infusion measurements in patients with CHD. The use of a bolus-only approach facilitates the integration of ECV measurements into existing CMR imaging protocols, allowing for assessment of diffuse myocardial fibrosis in CHD in clinical routine.

  15. Dobutamine stress myocardial perfusion imaging: 8-year outcomes in patients with diabetes mellitus.

    PubMed

    Boiten, Hendrik J; van Domburg, Ron T; Valkema, Roelf; Zijlstra, Felix; Schinkel, Arend F L

    2016-08-01

    Many studies have examined the prognostic value of myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) for the prediction of short- to medium-term outcomes. However, the long-term prognostic value of MPI in patients with diabetes mellitus remains unclear. Therefore, this study assessed the long-term prognostic value of MPI in a high-risk cohort of patients with diabetes mellitus. A high-risk cohort of 207 patients with diabetes mellitus who were unable to undergo exercise testing underwent dobutamine stress MPI. Follow-up was successful in 206 patients; 12 patients were excluded due to early revascularization. The current data are based on the remaining 194 patients. Follow-up end points were all-cause mortality, cardiac mortality, and nonfatal myocardial infarction. The Kaplan-Meier survival curves were constructed, and univariable and multivariable analyses were performed to identify predictors of long-term outcome. During a mean follow-up of 8.1 ± 5.9 years, 134 (69%) patients died of which 68 (35%) died due to cardiac causes. Nonfatal myocardial infarction occurred in 24 patients (12%), and late (>60 days) coronary revascularization was performed in 61 (13%) patients. Survival analysis showed that MPI provided optimal risk stratification up to 4 years after testing. After that period, the outcome was comparable in patients with normal and abnormal MPI. Multivariable analyses showed that MPI provided incremental prognostic value up to 4 years after testing. In high-risk patients with diabetes mellitus, dobutamine MPI provides incremental prognostic information in addition to clinical data for a 4-year period after testing. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  16. Interrupted infusion of echocardiographic contrast as a basis for accurate measurement of myocardial perfusion: ex vivo validation and analysis procedures.

    PubMed

    Toledo, Eran; Collins, Keith A; Williams, Ursula; Lammertin, Georgeanne; Bolotin, Gil; Raman, Jai; Lang, Roberto M; Mor-Avi, Victor

    2005-12-01

    Echocardiographic quantification of myocardial perfusion is based on analysis of contrast replenishment after destructive high-energy ultrasound impulses (flash-echo). This technique is limited by nonuniform microbubble destruction and the dependency on exponential fitting of a small number of noisy time points. We hypothesized that brief interruptions of contrast infusion (ICI) would result in uniform contrast clearance followed by slow replenishment and, thus, would allow analysis from multiple data points without exponential fitting. Electrocardiographic-triggered images were acquired in 14 isolated rabbit hearts (Langendorff) at 3 levels of coronary flow (baseline, 50%, and 15%) during contrast infusion (Definity) with flash-echo and with a 20-second infusion interruption. Myocardial videointensity was measured over time from flash-echo sequences, from which characteristic constant beta was calculated using an exponential fit. Peak contrast inflow rate was calculated from ICI data using analysis of local time derivatives. Computer simulations were used to investigate the effects of noise on the accuracy of peak contrast inflow rate and beta calculations. ICI resulted in uniform contrast clearance and baseline replenishment times of 15 to 25 cardiac cycles. Calculated peak contrast inflow rate followed the changes in coronary flow in all hearts at both levels of reduced flow (P < .05) and had a low intermeasurement variability of 7 +/- 6%. With flash-echo, contrast clearance was less uniform and baseline replenishment times were only 4 to 6 cardiac cycles. beta Decreased significantly only at 15% flow, and had intermeasurement variability of 42 +/- 33%. Computer simulations showed that measurement errors in both perfusion indices increased with noise, but beta had larger errors at higher rates of contrast inflow. ICI provides the basis for accurate and reproducible quantification of myocardial perfusion using fast and robust numeric analysis, and may constitute

  17. Prognostic Value of Myocardial Perfusion Analysis in Patients with Coronary Artery Disease: A Meta-Analysis.

    PubMed

    Xiu, Jiancheng; Cui, Kai; Wang, Yuegang; Zheng, Hua; Chen, Gangbin; Feng, Qian; Bin, Jianping; Wu, Juefei; Porter, Thomas R

    2017-03-01

    Myocardial perfusion (MP) imaging during stress myocardial contrast echocardiography (MCE) improves the detection of coronary artery disease (CAD). However, its prognostic value to predict cardiac events in patients with known or suspected CAD is still undefined. A search was conducted for single- or multicenter prospective studies that evaluated the prognostic value of stress MCE in patients with known or suspected CAD. A database search was performed through June 2015. Effect sizes of relative risk ratios (RRs) with their corresponding 95% CIs were used to evaluate the association between the occurrence of total cardiac events (cardiac death, nonfatal myocardial infarction, coronary revascularization) and hard cardiac events (cardiac death and nonfatal myocardial infarction) in subjects with normal and abnormal MP measured by MCE. The Cochran Q statistic and the I 2 statistic were used to assess heterogeneity. A comprehensive literature search of the MEDLINE, Google Scholar, Cochrane, and Embase databases identified 11 studies enrolling a total of 4,045 patients. The overall analysis of RRs revealed that patients with abnormal MP were at higher risk for total cardiac events compared with patients with normal MP (RR, 5.58; 95% CI, 3.64-8.57; P < .001), with low heterogeneity among trials (I 2  = 48.15%, Q = 7.71, P = .103). Similarly, patients with abnormal MP were at higher risk for hard cardiac events compared with patients with normal MP (RR, 4.99; 95% CI, 1.75-14.32; P = .003), with significant heterogeneity among trials (I 2  = 81.48%, Q = 21.59, P < .001). The results of this meta-analysis suggest that MP assessment using stress MCE is an effective prognostic tool for predicting the occurrence of cardiac events in patients with known or suspected CAD. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  18. Evaluation of (99)  (m)TcN-MPO as a new myocardial perfusion imaging agent in normal dogs and in an acute myocardial infarction canine model: comparison with (99)  (m)Tc-sestamibi.

    PubMed

    Bu, Lihong; Li, Renfei; Jin, Zhongnan; Wen, Xiaofei; Liu, Shuang; Yang, Baofeng; Shen, Baozhong; Chen, Xiaoyuan

    2011-02-01

    (99)  (m)TcN-MPO ([(99)  (m)TcN(mpo)(PNP5)](+): mpo = 2-mercaptopyridine oxide and PNP5 = N-ethoxyethyl-N,N-bis[2-(bis(3-methoxypropyl)phosphino)ethyl]amine) is a cationic (99)  (m)Tc-nitrido complex, which has favorable biodistribution and myocardial uptake with rapid liver clearance in Sprague Dawley rats. The objective of this study was to compare the biodistribution and pharmacokinetics of (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi in normal dogs, and to evaluate the potential of (99)  (m)TcN-MPO as a myocardial perfusion agent in canines with acute myocardial infarction. Five normal mongrel dogs were injected intravenously with (99)  (m)TcN-MPO. Venous blood samples were collected via a femoral vein catheter at 0.5, 1, 2, 3, 4, 5, 10, 20, 30, 40, 60, and 90 min post-injection (p.i.). Anterior-posterior planar images were acquired by γ-camera at 10, 20, 30, 60, 90, and 120 min p.i. Regions of interest (ROIs) were drawn around the heart, liver, and lungs. The heart/liver and heart/lung ratios were calculated by dividing the mean counts in heart ROI by the mean counts in the liver and lung ROI, respectively. For comparison, (99)  (m)Tc-sestamibi was also evaluated in the same five dogs. The interval period between the two examinations was 1 week to eliminate possible interference between these two radiotracers. In addition, single positron emission computed tomography (SPECT) images in the canine infarct model were collected 24 h after myocardial infarction at 30 and 60 min after the administration of (99)  (m)TcN-MPO (n = 4) or (99)  (m)Tc-Sestamibi (n = 4). It was found that (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi displayed very similar blood clearance characteristics during the first 90 min p.i. Both (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi had a rapid blood clearance with less than 50% of initial radioactivity remaining at 1 min and less than 5% at 30 min p.i. (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi both showed good

  19. Thrombus Aspiration in ThrOmbus containing culpRiT lesions in Non-ST-Elevation Myocardial Infarction (TATORT-NSTEMI): study protocol for a randomized controlled trial

    PubMed Central

    2013-01-01

    Background Current guidelines recommend thrombus aspiration in patients with ST-elevation myocardial infarction (STEMI); however, there are insufficient data to unequivocally support thrombectomy in patients with non-STEMI (NSTEMI). Methods/Design The TATORT-NSTEMI (Thrombus Aspiration in ThrOmbus containing culpRiT lesions in Non-ST-Elevation Myocardial Infarction) trial is a prospective, controlled, multicenter, randomized, open-label trial enrolling 460 patients. The hypothesis is that, against a background of early revascularization, adjunctive thrombectomy leads to less microvascular obstruction (MO) compared with conventional percutaneous coronary intervention (PCI) alone, as assessed by cardiac magnetic resonance imaging (CMR) in patients with NSTEMI. Patients will be randomized in a 1:1 fashion to one of the two treatment arms. The primary endpoint is the extent of late MO assessed by CMR. Secondary endpoints include early MO, infarct size, and myocardial salvage assessed by CMR as well as enzymatic infarct size and angiographic parameters, such as thrombolysis in myocardial infarction flow post-PCI and myocardial blush grade. Furthermore, clinical endpoints including death, myocardial re-infarction, target vessel revascularization, and new congestive heart failure will be recorded at 6 and 12 months. Safety will be assessed by the incidence of bleeding and stroke. Summary The TATORT-NSTEMI trial has been designed to test the hypothesis that thrombectomy will improve myocardial perfusion in patients with NSTEMI and relevant thrombus burden in the culprit vessel reperfused by early PCI. Trial registration The trial is registered under http://www.clinicaltrials.gov: NCT01612312. PMID:23782681

  20. The influence of microvascular injury on native T1 and T2* relaxation values after acute myocardial infarction: implications for non-contrast-enhanced infarct assessment.

    PubMed

    Robbers, Lourens F H J; Nijveldt, Robin; Beek, Aernout M; Teunissen, Paul F A; Hollander, Maurits R; Biesbroek, P Stefan; Everaars, Henk; van de Ven, Peter M; Hofman, Mark B M; van Royen, Niels; van Rossum, Albert C

    2018-02-01

    Native T1 mapping and late gadolinium enhancement (LGE) imaging offer detailed characterisation of the myocardium after acute myocardial infarction (AMI). We evaluated the effects of microvascular injury (MVI) and intramyocardial haemorrhage on local T1 and T2* values in patients with a reperfused AMI. Forty-three patients after reperfused AMI underwent cardiovascular magnetic resonance imaging (CMR) at 4 [3-5] days, including native MOLLI T1 and T2* mapping, STIR, cine imaging and LGE. T1 and T2* values were determined in LGE-defined regions of interest: the MI core incorporating MVI when present, the core-adjacent MI border zone (without any areas of MVI), and remote myocardium. Average T1 in the MI core was higher than in the MI border zone and remote myocardium. However, in the 20 (47%) patients with MVI, MI core T1 was lower than in patients without MVI (MVI 1048±78ms, no MVI 1111±89ms, p=0.02). MI core T2* was significantly lower in patients with MVI than in those without (MVI 20 [18-23]ms, no MVI 31 [26-39]ms, p<0.001). The presence of MVI profoundly affects MOLLI-measured native T1 values. T2* mapping suggested that this may be the result of intramyocardial haemorrhage. These findings have important implications for the interpretation of native T1 values shortly after AMI. • Microvascular injury after acute myocardial infarction affects local T1 and T2* values. • Infarct zone T1 values are lower if microvascular injury is present. • T2* mapping suggests that low infarct T1 values are likely haemorrhage. • T1 and T2* values are complimentary for correctly assessing post-infarct myocardium.

  1. [Acute stent thrombosis and reverse transient left ventricular dilatation after performing a single-photon emission computed tomography myocardial perfusion].

    PubMed

    Miranda, B; Pizzi, M N; Aguadé-Bruix, S; Domingo, E; Candell-Riera, J

    2015-01-01

    A 63-year-old male patient with a history of stent implantation in the left anterior descending three months before. Due to the presentation of vegetative symptoms, he was referred for gated-SPECT myocardial perfusion. During acquisition of the resting images he presented chest pain and ST segment elevation, so that urgent cardiac catheterization was performed, showing stent thrombosis. Rest perfusion imaging showed a defect in anterior and apical perfusion, more severe and extensive than in the stress images, with striking left ventricular dilatation and a fall in the ejection fraction related to the acute ischemia phenomenon. Intense exercise is associated with a transient activation of the coagulation system and hemodynamic changes that might induce thrombosis, especially in recently implanted coronary stents that probably still have not become completely endothelialized. Copyright © 2014 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  2. Myocardial T2* Mapping at Ultrahigh Field: Physics and Frontier Applications

    NASA Astrophysics Data System (ADS)

    Huelnhagen, Till; Paul, Katharina; Ku, Min-Chi; Serradas Duarte, Teresa; Niendorf, Thoralf

    2017-06-01

    Cardiovascular magnetic resonance imaging (CMR) has become an indispensable clinical tool for the assessment of morphology, function and structure of the heart muscle. By exploiting quantification of the effective transverse relaxation time (T2*) CMR also affords myocardial tissue characterization and probing of cardiac physiology, both being in the focus of ongoing research. These developments are fueled by the move to ultrahigh magnetic field strengths, which permits enhanced sensitivity and spatial resolution that help to overcome limitations of current clinical MR systems with the goal to contribute to a better understanding of myocardial (patho)physiology in vivo. In this context, the aim of this report is to introduce myocardial T2* mapping at ultrahigh magnetic fields as a promising technique to non-invasively assess myocardial (patho)physiology. For this purpose the basic principles of T2* assessment, the biophysical mechanisms determining T2* and (pre)clinical applications of myocardial T2* mapping are presented. Technological challenges and solutions for T2* sensitized CMR at ultrahigh magnetic field strengths are discussed followed by a review of acquisition techniques and post processing approaches. Preliminary results derived from myocardial T2* mapping in healthy subjects and cardiac patients at 7.0 Tesla are presented. A concluding section discusses remaining questions and challenges and provides an outlook on future developments and potential clinical applications.

  3. Right Ventricular Dysfunction Impairs Effort Tolerance Independent of Left Ventricular Function Among Patients Undergoing Exercise Stress Myocardial Perfusion Imaging.

    PubMed

    Kim, Jiwon; Di Franco, Antonino; Seoane, Tania; Srinivasan, Aparna; Kampaktsis, Polydoros N; Geevarghese, Alexi; Goldburg, Samantha R; Khan, Saadat A; Szulc, Massimiliano; Ratcliffe, Mark B; Levine, Robert A; Morgan, Ashley E; Maddula, Pooja; Rozenstrauch, Meenakshi; Shah, Tara; Devereux, Richard B; Weinsaft, Jonathan W

    2016-11-01

    Right ventricular (RV) and left ventricular (LV) function are closely linked due to a variety of factors, including common coronary blood supply. Altered LV perfusion holds the potential to affect the RV, but links between LV ischemia and RV performance, and independent impact of RV dysfunction on effort tolerance, are unknown. The population comprised 2051 patients who underwent exercise stress myocardial perfusion imaging and echo (5.5±7.9 days), among whom 6% had echo-evidenced RV dysfunction. Global summed stress scores were ≈3-fold higher among patients with RV dysfunction, attributable to increments in inducible and fixed LV perfusion defects (all P≤0.001). Regional inferior and lateral wall ischemia was greater among patients with RV dysfunction (both P<0.01), without difference in corresponding anterior defects (P=0.13). In multivariable analysis, inducible inferior and lateral wall perfusion defects increased the likelihood of RV dysfunction (both P<0.05) independent of LV function, fixed perfusion defects, and pulmonary artery pressure. Patients with RV dysfunction demonstrated lesser effort tolerance whether measured by exercise duration (6.7±2.8 versus 7.9±2.9 minutes; P<0.001) or peak treadmill stage (2.6±0.9 versus 3.1±1.0; P<0.001), paralleling results among patients with LV dysfunction (7.0±2.9 versus 8.0±2.9; P<0.001|2.7±1.0 versus 3.1±1.0; P<0.001 respectively). Exercise time decreased stepwise in relation to both RV and LV dysfunction (P<0.001) and was associated with each parameter independent of age or medication regimen. Among patients with known or suspected coronary artery disease, regional LV ischemia involving the inferior and lateral walls confers increased likelihood of RV dysfunction. RV dysfunction impairs exercise tolerance independent of LV dysfunction. © 2016 American Heart Association, Inc.

  4. Optimization of OSEM parameters in myocardial perfusion imaging reconstruction as a function of body mass index: a clinical approach*

    PubMed Central

    de Barros, Pietro Paolo; Metello, Luis F.; Camozzato, Tatiane Sabriela Cagol; Vieira, Domingos Manuel da Silva

    2015-01-01

    Objective The present study is aimed at contributing to identify the most appropriate OSEM parameters to generate myocardial perfusion imaging reconstructions with the best diagnostic quality, correlating them with patients’ body mass index. Materials and Methods The present study included 28 adult patients submitted to myocardial perfusion imaging in a public hospital. The OSEM method was utilized in the images reconstruction with six different combinations of iterations and subsets numbers. The images were analyzed by nuclear cardiology specialists taking their diagnostic value into consideration and indicating the most appropriate images in terms of diagnostic quality. Results An overall scoring analysis demonstrated that the combination of four iterations and four subsets has generated the most appropriate images in terms of diagnostic quality for all the classes of body mass index; however, the role played by the combination of six iterations and four subsets is highlighted in relation to the higher body mass index classes. Conclusion The use of optimized parameters seems to play a relevant role in the generation of images with better diagnostic quality, ensuring the diagnosis and consequential appropriate and effective treatment for the patient. PMID:26543282

  5. Evaluation of changes in perfusion defect and left ventricular systolic function using Tc-99m Tetrofosmin single photon emission computed tomography over 3 month period in patients of Acute Myocardial Infarction undergoing primary angioplasty.

    PubMed

    Kumar, Avs Anil; Kumar, P G; Swami, Ajay; Dinker, Yateendra

    2018-01-01

    After a primary transluminal coronary angioplasty (PTCA) following AMI (acute myocardial infarction), the perfusion defect and LV (left ventricular) function recover/change over a period of time. The analysis immediately after the procedure may not be true depiction of the exact success of the procedure. There is varying and scanty information available on the natural course of changes in these parameters after a successful PTCA. We hypothesized that majority of change occurs at 3-4 month period. Hence, we undertook this study on the natural course of recovery/changes occurring in perfusion defect size and LV function in first 3 months after primary angioplasty MATERIAL AND METHODS: 30 consecutive cases of first AMI who were taken up for Primary angioplasty were enrolled into the study. Resting MPI(Myocardial perfusion imaging) was done within 24-72 hrs of admission using Tc-99m-Tetrofosmin and after 10-14 weeks. Analysis of LVEF (left ventricular ejection fraction), summed segmental score and extent of perfusion defect was done. Images were processed using autocardiac software of emory tool box and quantification was done using QPS (quantitative perfusion SPECT) and QGS (qualitative perfusion SPECT) softwares. 20 segment scoring method was used for quantification on bull's eye images. Student t test (two tailed, dependent) was used to find the significance of study parameters on continuous scale within each group. Effect size was computed to find the effect. Pearson correlation between perfusion defect and LVEF was performed at acute stage and after 10-14 weeks. The average acute perfusion defect extent was 19.76 ± 12.89% which after 3months became 16.79 ± 12.61%. The summed segmental score changed from 14.31 ± 10.58 to 11.38 ± 10.03 and LVEF improved from 48.40 ± 13.15% to 53.37 ± 12.8%. There was significant improvement in LVEF from acute setting to 10-14 weeks (p = 0.001). There was significant lowering of summed score (p = 0.007). Perfusion defect size

  6. Distribution and Determinants of Myocardial Perfusion Grade Following Late Mechanical Recanalization of Occluded Infarct-Related Arteries Postmyocardial Infarction: A Report From the Occluded Artery Trial

    PubMed Central

    Jorapur, Vinod; Steigen, Terje K.; Buller, Christopher E.; Dẑavík, Vladimír; Webb, John G.; Strauss, Bradley H.; Yeoh, Eunice E.S.; Kurray, Peter; Sokalski, Leszek; Machado, Mauricio C.; Kronsberg, Shari S.; Lamas, Gervasio A.; Hochman, Judith S.; John Mancini, G.B.

    2010-01-01

    Objective To evaluate the distribution and determinants of myocardial perfusion grade (MPG) following late recanalization of persistently occluded infarct-related arteries (IRA). Background MPG reflects microvascular integrity. It is an independent prognostic factor following myocardial infarction, but has been studied mainly in the setting of early reperfusion. The occluded artery trial (OAT) enrolled stable patients with persistently occluded IRAs beyond 24 hr and up to 28 days post-MI. Methods Myocardial blush was assessed using TIMI MPG grading in 261 patients with TIMI 3 epicardial flow following IRA PCI. Patients demonstrating impaired (0–1) versus preserved (2–3) MPG were compared with regard to baseline clinical and pre-PCI angiographic characteristics. Results Impaired MPG was observed in 60 of 261 patients (23%). By univariate analysis, impaired MPG was associated with failed fibrinolytic therapy, higher heart rate, lower systolic blood pressure, lower ejection fraction, LAD occlusion, absence of collaterals (P < 0.01) and ST elevation MI, lower diastolic blood pressure, and higher systolic sphericity index (P < 0.05). By multivariable analysis, higher heart rate, LAD occlusion, absence of collaterals and higher systolic sphericity index (P < 0.01), and lower systolic blood pressure (P < 0.05) were independently associated with impaired MPG. Conclusion Preserved microvascular integrity was present in a high proportion of patients following late recanalization of occluded IRAs post-MI. Presence of collaterals was independently associated with preserved MPG and likely accounted for the high frequency of preserved myocardial perfusion in this clinical setting. Impaired MPG was associated with baseline clinical and angiographic features consistent with larger infarct size. PMID:18798327

  7. Platelet counts on admission affect coronary flow, myocardial perfusion and left ventricular systolic function after primary percutaneous coronary intervention.

    PubMed

    Sharif, Dawod; Abu-Salem, Mira; Sharif-Rasslan, Amal; Rosenschein, Uri

    2017-10-01

    Patients with acute ST-elevation myocardial infarction (STEMI) and increased platelet count treated by fibrinolysis have worse outcomes. The aim of this study was to test the hypothesis that platelet blood count at admission in patients with acute STEMI treated by primary percutaneous coronary intervention affects coronary flow, myocardial perfusion and recovery of left ventricular systolic function. A total of 174 patients presenting with acute anterior STEMI and treated with primary percutaneous coronary intervention were included and divided into subgroups of admission platelet blood count of <200 K, 200-300 K, 300-400 K and >400 K. Evaluation of coronary artery flow and myocardial blush grade was performed according to the TIMI criteria. Electrocardiographic ST elevation resolution post-primary percutaneous coronary intervention was evaluated. Doppler echocardiographic evaluation of left anterior descending coronary artery velocities early and late after primary percutaneous coronary intervention and assessment of left ventricular ejection fraction and wall motion score index (WMSI) of left ventricular and left anterior descending coronary artery territory were performed. Post-primary percutaneous coronary intervention TIMI, myocardial blush grade and ST elevation resolution were similar in all groups. Patients with platelet counts <200 K had higher peak diastolic left anterior descending coronary artery velocity both early and late after primary percutaneous coronary intervention, and higher prevalence of left anterior descending coronary artery velocity deceleration time exceeding 600 ms, (45.5% vs. 40%, P<0.05). Patients with platelet counts >400 K presented with worse left ventricular ejection fraction, left ventricular WMSI and left anterior descending coronary artery WMSI, and before discharge this subgroup had worse left ventricular WMSI and left anterior descending coronary artery WMSI, P<0.01. Patients with anterior STEMI treated by primary

  8. Nuclear cardiology: Part 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berger, H.J.; Zaret, B.L.

    1981-10-01

    A review of recent developments and future directions in nuclear cardiology is presented. Myocardial perfusion imaging is discussed with special emphasis on thallium-201 methods. Infarct-avid imaging is also discussed with emphasis on technetium-99m labelled in diagnosis, and emission computed tomography is briefly reviewed. In addition, new biologically based radiotracers such as indium-111-labeled blood cells, gallium-67 citrate, and new positron- and gamma-emittng radiotracers are reviewed.

  9. Impact of rosiglitazone and glyburide on nitrosative stress and myocardial blood flow regulation in type 2 diabetes mellitus.

    PubMed

    Pop-Busui, Rodica; Oral, Elif; Raffel, David; Byun, Jaeman; Bajirovic, Valida; Vivekanandan-Giri, Anuradha; Kellogg, Aaron; Pennathur, Subramaniam; Stevens, Martin J

    2009-07-01

    Cardiovascular disease, the leading cause of death in patients with type 2 diabetes mellitus (T2DM), is usually preceded by endothelial dysfunction and altered myocardial blood flow (MBF) regulation. Hyperglycemia, oxidative-nitrosative stress, systemic inflammation, and insulin resistance are implicated in the pathogenesis of abnormal MBF regulation, myocardial ischemia, and apoptosis. However, the impact of oral antihyperglycemic therapy on myocardial perfusion is controversial. Our objective was to explore the effect of rosiglitazone and glyburide on nitrosative stress and MBF regulation in subjects with T2DM. [(13)N]ammonia positron emission tomography and cold pressor testing were used in 27 diabetic subjects (mean age, 49 +/- 11 years; glycohemoglobin, 7% +/- 1.5%) randomized to either rosiglitazone 8 mg/d or glyburide 10 mg/d for 6 months. Isotope dilution gas chromatography-mass spectrometry was used to quantify plasma 3-nitrotyrosine, a stable marker of reactive nitrogen species. At 6 months, there were no significant differences between groups in the mean glycohemoglobin, blood pressure, or plasma lipids. Rosiglitazone significantly reduced plasma nitrotyrosine, high-sensitivity C-reactive protein, and von Willebrand antigen (P < .03 for all) and significantly increased plasma adiponectin (P < .05). No significant changes in these parameters were observed with glyburide. Treatment with glyburide, but not rosiglitazone, resulted in a significant deterioration in both resting and stress MBF. Rosiglitazone, but not glyburide, ameliorated markers of nitrosative stress and inflammation in subjects with T2DM without impairing myocardial perfusion.

  10. Biodistribution and Stability Studies of [18F]Fluoroethylrhodamine B, a Potential PET Myocardial Perfusion Agent

    PubMed Central

    Gottumukkala, Vijay; Heinrich, Tobias K.; Baker, Amanda; Dunning, Patricia; Fahey, Frederick H; Treves, S. Ted; Packard, Alan B.

    2010-01-01

    Introduction Fluorine-18-labeled rhodamine B was developed as a potential PET tracer for the evaluation of myocardial perfusion, but preliminary studies in mice showed no accumulation in the heart suggesting that it was rapidly hydrolyzed in vivo in mice. A study was, therefore, undertaken to further evaluate this hypothesis. Methods [18F]Fluoroethylrhodamine B was equilibrated for 2 h at 37 °C in human, rat and mouse serum and in PBS. Samples were removed periodically and assayed by HPLC. Based on the results of the stability study, microPET imaging and a biodistribution study were carried out in rats. Results In vitro stability studies demonstrated that [18F]fluoroethylrhodamine B much more stable in rat and human sera than in mouse serum. After 2 h, the compound was >80% intact in rat serum but <30% intact in mouse serum. The microPET imaging and biodistribution studies in rats confirmed this result showing high and persistent tracer accumulation in the myocardium compared with the absence of uptake by the myocardium in mice thereby validating our original hypothesis that 18F-labeled rhodamines should accumulate in the heart. Conclusions [18F]Fluoroethyl rhodamine B is more stable in rat and human sera than it is in mouse serum. This improved stability is demonstrated by the high uptake of the tracer in the rat heart in comparison to the absence of visible uptake in the mouse heart. These observations suggest that 18F-labeled rhodamines are promising candidates for more extensive evaluation as PET tracers for the evaluation of myocardial perfusion. PMID:20346876

  11. High-resolution myocardial T1 mapping using single-shot inversion recovery fast low-angle shot MRI with radial undersampling and iterative reconstruction

    PubMed Central

    Joseph, Arun A; Kalentev, Oleksandr; Merboldt, Klaus-Dietmar; Voit, Dirk; Roeloffs, Volkert B; van Zalk, Maaike; Frahm, Jens

    2016-01-01

    Objective: To develop a novel method for rapid myocardial T1 mapping at high spatial resolution. Methods: The proposed strategy represents a single-shot inversion recovery experiment triggered to early diastole during a brief breath-hold. The measurement combines an adiabatic inversion pulse with a real-time readout by highly undersampled radial FLASH, iterative image reconstruction and T1 fitting with automatic deletion of systolic frames. The method was implemented on a 3-T MRI system using a graphics processing unit-equipped bypass computer for online application. Validations employed a T1 reference phantom including analyses at simulated heart rates from 40 to 100 beats per minute. In vivo applications involved myocardial T1 mapping in short-axis views of healthy young volunteers. Results: At 1-mm in-plane resolution and 6-mm section thickness, the inversion recovery measurement could be shortened to 3 s without compromising T1 quantitation. Phantom studies demonstrated T1 accuracy and high precision for values ranging from 300 to 1500 ms and up to a heart rate of 100 beats per minute. Similar results were obtained in vivo yielding septal T1 values of 1246 ± 24 ms (base), 1256 ± 33 ms (mid-ventricular) and 1288 ± 30 ms (apex), respectively (mean ± standard deviation, n = 6). Conclusion: Diastolic myocardial T1 mapping with use of single-shot inversion recovery FLASH offers high spatial resolution, T1 accuracy and precision, and practical robustness and speed. Advances in knowledge: The proposed method will be beneficial for clinical applications relying on native and post-contrast T1 quantitation. PMID:27759423

  12. Myocardial imaging with 99mTc-Tetrofosmin: Influence of post-stress acquisition time, regional radiotracer uptake, and wall motion abnormalities on the clinical result.

    PubMed

    Giorgetti, Assuero; Kusch, Annette; Casagranda, Mirta; Tagliavia, Irene D'Aragona; Marzullo, Paolo

    2010-04-01

    We previously demonstrated that early (15', T1) post-stress myocardial imaging with Tetrofosmin could be more accurate than standard acquisitions (45', T2) in identifying coronary artery disease. To clarify this phenomenon, 120 subjects (age 61 +/- 10 years) with both T1 and T2 scans were divided into Group 1 (53/120 pts) with more ischemia at T1 vs T2 imaging (T1-T2SDS > or = 3); Group 2 (67/120 pts) with similar results (T1-T2SDS < or = 2). Myocardial areas were categorized as control nonischemic, ischemic, and scarred on the basis of perfusion/contraction properties and coronary anatomy. In each area, regional myocardial count statistic and semiquantitative wall motion/thickening values were obtained. Analysis of T1 and T2 post-stress myocardial counts demonstrated a significant Tetrofosmin wash-out rate that was higher in Group 1 control nonischemic regions (15 +/- 8% vs 13.6 +/- 9.6%, P < .02), significantly lower in Group 1 ischemic regions (7 +/- 10% vs 12.2 +/- 9.5%, P < .0001), and comparable between scarred areas of the two groups (P = NS). Delta post-stress wall thickening (T1-T2) was lower in Group 1 ischemic regions (-4.5 +/- 9.15% vs -1.90 +/- 7.0%, P < .001) and comparable in both control nonischemic and scarred areas of the two groups (P = NS). The clinical result of Tetrofosmin gated-SPECT can be influenced by the post-stress acquisition time because of ischemic-induced regional wall thickening abnormalities and the existence of a differential radiotracer myocardial wash-out.

  13. 22 CFR 20.1 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Definitions. 20.1 Section 20.1 Foreign Relations DEPARTMENT OF STATE PERSONNEL BENEFITS FOR CERTAIN FORMER SPOUSES § 20.1 Definitions. As used in this part, unless otherwise specified, the following have the meaning indicated: COLA means cost-of...

  14. 22 CFR 20.1 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 22 Foreign Relations 1 2014-04-01 2014-04-01 false Definitions. 20.1 Section 20.1 Foreign Relations DEPARTMENT OF STATE PERSONNEL BENEFITS FOR CERTAIN FORMER SPOUSES § 20.1 Definitions. As used in this part, unless otherwise specified, the following have the meaning indicated: COLA means cost-of...

  15. 22 CFR 20.1 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 22 Foreign Relations 1 2012-04-01 2012-04-01 false Definitions. 20.1 Section 20.1 Foreign Relations DEPARTMENT OF STATE PERSONNEL BENEFITS FOR CERTAIN FORMER SPOUSES § 20.1 Definitions. As used in this part, unless otherwise specified, the following have the meaning indicated: COLA means cost-of...

  16. 22 CFR 20.1 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Definitions. 20.1 Section 20.1 Foreign Relations DEPARTMENT OF STATE PERSONNEL BENEFITS FOR CERTAIN FORMER SPOUSES § 20.1 Definitions. As used in this part, unless otherwise specified, the following have the meaning indicated: COLA means cost-of...

  17. 22 CFR 20.1 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Definitions. 20.1 Section 20.1 Foreign Relations DEPARTMENT OF STATE PERSONNEL BENEFITS FOR CERTAIN FORMER SPOUSES § 20.1 Definitions. As used in this part, unless otherwise specified, the following have the meaning indicated: COLA means cost-of...

  18. Cardiac T1 Imaging

    PubMed Central

    Jerosch-Herold, Michael; Kwong, Raymond Y.

    2014-01-01

    T1 mapping of the heart has evolved into a valuable tool to evaluate myocardial tissue properties, with or without contrast injection, including assessment of myocardial edema and free water content, extra-cellular volume (expansion), and most recently cardiomyocyte hypertrophy. The MRI pulse sequence techniques developed for these applications have had to address at least two important considerations for cardiac applications: measure magnetization inversion recoveries during cardiac motion with sufficient temporal resolution for the shortest expected T1 values, and, secondly, obtain these measurements within a time during which a patient can comfortably suspend breathing. So-called Look-Locker techniques, and variants thereof, which all sample multiple points of a magnetization recovery after each magnetization preparation have therefore become a mainstay in this field. The rapid pace of advances and new findings based on cardiac T1 mapping for assessment of diffuse fibrosis, or myocardial edema show that these techniques enrich the capabilities of MRI for myocardial tissue profiling, which is arguably unmatched by other cardiac imaging modalities. PMID:24509619

  19. 4 CFR 201.1 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 4 Accounts 1 2010-01-01 2010-01-01 false Scope. 201.1 Section 201.1 Accounts RECOVERY ACCOUNTABILITY AND TRANSPARENCY BOARD PUBLIC INFORMATION AND REQUESTS § 201.1 Scope. This part sets forth the... access to documents under the Freedom of Information Act (FOIA or the Act), 5 U.S.C. 552. The provisions...

  20. Gated-SPECT myocardial perfusion imaging as a complementary technique to magnetic resonance imaging in chronic myocardial infarction patients.

    PubMed

    Cuberas-Borrós, Gemma; Pineda, Victor; Aguadé-Bruix, Santiago; Romero-Farina, Guillermo; Pizzi, M Nazarena; de León, Gustavo; Castell-Conesa, Joan; García-Dorado, David; Candell-Riera, Jaume

    2013-09-01

    The aim of this study was to compare magnetic resonance and gated-SPECT myocardial perfusion imaging in patients with chronic myocardial infarction. Magnetic resonance imaging and gated-SPECT were performed in 104 patients (mean age, 61 [12] years; 87.5% male) with a previous infarction. Left ventricular volumes and ejection fraction and classic late gadolinium enhancement viability criteria (<75% transmurality) were correlated with those of gated-SPECT (uptake >50%) in the 17 segments of the left ventricle. Motion, thickening, and ischemia on SPECT were analyzed in segments showing nonviable tissue or equivocal enhancement features (50%-75% transmurality). A good correlation was observed between the 2 techniques for volumes, ejection fraction (P<.05), and estimated necrotic mass (P<.01). In total, 82 of 264 segments (31%) with >75% enhancement had >50% single SPECT uptake. Of the 106 equivocal segments on magnetic resonance imaging, 68 (64%) had >50% uptake, 41 (38.7%) had normal motion, 46 (43.4%) had normal thickening, and 17 (16%) had ischemic criteria on SPECT. A third of nonviable segments on magnetic resonance imaging showed >50% uptake on SPECT. Gated-SPECT can be useful in the analysis of motion, thickening, and ischemic criteria in segments with questionable viability on magnetic resonance imaging. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  1. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies.

    PubMed

    Petibon, Yoann; Rakvongthai, Yothin; El Fakhri, Georges; Ouyang, Jinsong

    2017-05-07

    Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18 F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans-each containing 1/8th of the total number of events-were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18 F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other

  2. Intravenous Xenogeneic Transplantation of Human Adipose-Derived Stem Cells Improves Left Ventricular Function and Microvascular Integrity in Swine Myocardial Infarction Model

    PubMed Central

    Jun Hong, Soon; Rogers, Pamela I.; Kihlken, John; Warfel, Jessica; Bull, Chris; Deuter-Reinhard, Maja; Feng, Dongni; Xie, Jie; Kyle, Aaron; Merfeld-Clauss, Stephanie; Johnstone, Brian H.; Traktuev, Dmitry O.; Chen, Peng-Sheng; Lindner, Jonathan R.; March, Keith L.

    2018-01-01

    Objectives The potential for beneficial effects of adipose-derived stem cells(ASCs) on myocardial perfusion and left ventricular dysfunction in myocardial ischemia(MI) has not been tested following intravenous delivery. Methods Surviving pigs following induction of MI were randomly assigned to 1 of 3 different groups: the placebo group (n=7), the single bolus group (SB)(n=7, 15×107 ASCs), or the divided dose group (DD)(n=7, 5×107 ASCs/day for three consecutive days). Myocardial perfusion defect area and coronary flow reserve (CFR) were compared during the 28-day follow-up. Also, serial changes in the absolute number of circulating CD4+T and CD8+T cells were measured. Results The increases in ejection fraction were significantly greater in both the SB and the DD groups compared to the placebo group (5.4±0.9%, 3.7±0.7%, and -0.4±0.6%, respectively), and the decrease in the perfusion defect area was significantly greater in the SB group than the placebo group (-36.3±1.8 and -11.5±2.8). CFR increased to a greater degree in the SB and the DD groups than in the placebo group (0.9±0.2, 0.8±0.1, and 0.2±0.2, respectively). The circulating number of CD8+T cells was significantly greater in the SB and DD groups than the placebo group at day 7(3,687±317/μL, 3,454±787/μL, and 1,928±457/μL, respectively). The numbers of small vessels were significantly greater in the SB and the DD groups than the placebo group in the peri-infarct area. Conclusions Both intravenous SB and DD delivery of ASCs are effective modalities for the treatment of MI in swine. Intravenous delivery of ASCs, with its immunomodulatory and angiogenic effects, is an attractive noninvasive approach for myocardial rescue. PMID:24905889

  3. Direct T2 Quantification of Myocardial Edema in Acute Ischemic Injury

    PubMed Central

    Verhaert, David; Thavendiranathan, Paaladinesh; Giri, Shivraman; Mihai, Georgeta; Rajagopalan, Sanjay; Simonetti, Orlando P.; Raman, Subha V.

    2014-01-01

    OBJECTIVES To evaluate the utility of rapid, quantitative T2 mapping compared with conventional T2-weighted imaging in patients presenting with various forms of acute myocardial infarction. BACKGROUND T2-weighted cardiac magnetic resonance (CMR) identifies myocardial edema before the onset of irreversible ischemic injury and has shown value in risk-stratifying patients with chest pain. Clinical acceptance of T2-weighted CMR has, however, been limited by well-known technical problems associated with existing techniques. T2 quantification has recently been shown to overcome these problems; we hypothesized that T2 measurement in infarcted myocardium versus remote regions versus zones of microvascular obstruction in acute myocardial infarction patients could help reduce uncertainty in interpretation of T2-weighted images. METHODS T2 values using a novel mapping technique were prospectively recorded in 16 myocardial segments in 27 patients admitted with acute myocardial infarction. Regional T2 values were averaged in the infarct zone and remote myocardium, both defined by a reviewer blinded to the results of T2 mapping. Myocardial T2 was also measured in a group of 21 healthy volunteers. RESULTS T2 of the infarct zone was 69 ± 6 ms compared with 56 ± 3.4 ms for remote myocardium (p < 0.0001). No difference in T2 was observed between remote myocardium and myocardium of healthy volunteers (56 ± 3.4 ms and 55.5 ± 2.3 ms, respectively, p = NS). T2 mapping allowed for the detection of edematous myocardium in 26 of 27 patients; by comparison, segmented breath-hold T2-weighted short tau inversion recovery images were negative in 7 and uninterpretable in another 2 due to breathing artifacts. Within the infarct zone, areas of microvascular obstruction were characterized by a lower T2 value (59 ± 6 ms) compared with areas with no microvascular obstruction (71.6 ± 10 ms, p < 0.0001). T2 mapping provided consistent high-quality results in patients unable to breath-hold and in

  4. Cardiac phase-synchronized myocardial thallium-201 single-photon emission tomography using list mode data acquisition and iterative tomographic reconstruction.

    PubMed

    Vemmer, T; Steinbüchel, C; Bertram, J; Eschner, W; Kögler, A; Luig, H

    1997-03-01

    The purpose of this study was to determine whether data acquisition in the list mode and iterative tomographic reconstruction would render feasible cardiac phase-synchronized thallium-201 single-photon emission tomography (SPET) of the myocardium under routine conditions without modifications in tracer dose, acquisition time, or number of steps of the a gamma camera. Seventy non-selected patients underwent 201T1 SPET imaging according to a routine protocol (74 MBq/2 mCi 201T1, 180 degrees rotation of the gamma camera, 32 steps, 30 min). Gamma camera data, ECG, and a time signal were recorded in list mode. The cardiac cycle was divided into eight phases, the end-diastolic phase encompassing the QRS complex, and the end-systolic phase the T wave. Both phase- and non-phase-synchronized tomograms based on the same list mode data were reconstructed iteratively. Phase-synchronized and non-synchronized images were compared. Patients were divided into two groups depending on whether or not coronary artery disease had been definitely diagnosed prior to SPET imaging. The numbers of patients in both groups demonstrating defects visible on the phase-synchronized but not on the non-synchronized images were compared. It was found that both postexercise and redistribution phase tomograms were suited for interpretation. The changes from end-diastolic to end-systolic images allowed a comparative assessment of regional wall motility and tracer uptake. End-diastolic tomograms provided the best definition of defects. Additional defects not apparent on non-synchronized images were visible in 40 patients, six of whom did not show any defect on the non-synchronized images. Of 42 patients in whom coronary artery disease had been definitely diagnosed, 19 had additional defects not visible on the non-synchronized images, in comparison to 21 of 28 in whom coronary artery disease was suspected (P < 0.02; chi 2). It is concluded that cardiac phase-synchronized 201T1 SPET of the myocardium was

  5. Localized Spatio-Temporal Constraints for Accelerated CMR Perfusion

    PubMed Central

    Akçakaya, Mehmet; Basha, Tamer A.; Pflugi, Silvio; Foppa, Murilo; Kissinger, Kraig V.; Hauser, Thomas H.; Nezafat, Reza

    2013-01-01

    Purpose To develop and evaluate an image reconstruction technique for cardiac MRI (CMR)perfusion that utilizes localized spatio-temporal constraints. Methods CMR perfusion plays an important role in detecting myocardial ischemia in patients with coronary artery disease. Breath-hold k-t based image acceleration techniques are typically used in CMR perfusion for superior spatial/temporal resolution, and improved coverage. In this study, we propose a novel compressed sensing based image reconstruction technique for CMR perfusion, with applicability to free-breathing examinations. This technique uses local spatio-temporal constraints by regularizing image patches across a small number of dynamics. The technique is compared to conventional dynamic-by-dynamic reconstruction, and sparsity regularization using a temporal principal-component (pc) basis, as well as zerofilled data in multi-slice 2D and 3D CMR perfusion. Qualitative image scores are used (1=poor, 4=excellent) to evaluate the technique in 3D perfusion in 10 patients and 5 healthy subjects. On 4 healthy subjects, the proposed technique was also compared to a breath-hold multi-slice 2D acquisition with parallel imaging in terms of signal intensity curves. Results The proposed technique results in images that are superior in terms of spatial and temporal blurring compared to the other techniques, even in free-breathing datasets. The image scores indicate a significant improvement compared to other techniques in 3D perfusion (2.8±0.5 vs. 2.3±0.5 for x-pc regularization, 1.7±0.5 for dynamic-by-dynamic, 1.1±0.2 for zerofilled). Signal intensity curves indicate similar dynamics of uptake between the proposed method with a 3D acquisition and the breath-hold multi-slice 2D acquisition with parallel imaging. Conclusion The proposed reconstruction utilizes sparsity regularization based on localized information in both spatial and temporal domains for highly-accelerated CMR perfusion with potential utility in free

  6. 48 CFR 1.201-1 - The two councils.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false The two councils. 1.201-1 Section 1.201-1 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 1.201-1 The two councils. (a) Subject to the authorities...

  7. The Effect of the Prosthetic Group on the Pharmacologic Properties of 18F-labeled Rhodamine B, a Potential Myocardial Perfusion Agent for PET

    PubMed Central

    Bartholomä, Mark D.; Gottumukkala, Vijay; Zhang, Shaohui; Baker, Amanda; Dunning, Patricia; Fahey, Frederic H.; Treves, S. Ted; Packard, Alan B.

    2013-01-01

    We recently reported the development of the 2-[18F]fluoroethyl ester of rhodamine B as a potential positron emission tomography (PET) tracer for myocardial perfusion imaging. This compound, which was prepared using a [18F]fluoroethyl prosthetic group, has significant uptake in the myocardium in rats, but also demonstrates relatively high liver uptake and is rapidly hydrolyzed in vivo in mice. We have now prepared 18F-labeled rhodamine B using three additional prosthetic groups (propyl, diethylene glycol, and triethylene glycol) and found that the prosthetic group has a significant effect on the in vitro and in vivo properties of these compounds. Of the esters prepared to date, the diethylene glycol ester is superior in terms of in vitro stability and pharmacokinetics. These observations suggest that the prosthetic group plays a significant role in determining the pharmacological properties of 18F-labeled compounds. They also support the value of continued investigation of 18F-labeled rhodamines as PET radiopharmaceuticals for myocardial perfusion imaging. PMID:23210516

  8. Radionuclide Myocardial Perfusion Imaging for the Evaluation of Patients With Known or Suspected Coronary Artery Disease in the Era of Multimodality Cardiovascular Imaging

    PubMed Central

    Taqueti, Viviany R.; Di Carli, Marcelo F.

    2018-01-01

    Over the last several decades, radionuclide myocardial perfusion imaging (MPI) with single photon emission tomography and positron emission tomography has been a mainstay for the evaluation of patients with known or suspected coronary artery disease (CAD). More recently, technical advances in separate and complementary imaging modalities including coronary computed tomography angiography, computed tomography perfusion, cardiac magnetic resonance imaging, and contrast stress echocardiography have expanded the toolbox of diagnostic testing for cardiac patients. While the growth of available technologies has heralded an exciting era of multimodality cardiovascular imaging, coordinated and dispassionate utilization of these techniques is needed to implement the right test for the right patient at the right time, a promise of “precision medicine.” In this article, we review the maturing role of MPI in the current era of multimodality cardiovascular imaging, particularly in the context of recent advances in myocardial blood flow quantitation, and as applied to the evaluation of patients with known or suspected CAD. PMID:25770849

  9. Right Ventricular Perfusion: Physiology and Clinical Implications.

    PubMed

    Crystal, George J; Pagel, Paul S

    2018-01-01

    Regulation of blood flow to the right ventricle differs significantly from that to the left ventricle. The right ventricle develops a lower systolic pressure than the left ventricle, resulting in reduced extravascular compressive forces and myocardial oxygen demand. Right ventricular perfusion has eight major characteristics that distinguish it from left ventricular perfusion: (1) appreciable perfusion throughout the entire cardiac cycle; (2) reduced myocardial oxygen uptake, blood flow, and oxygen extraction; (3) an oxygen extraction reserve that can be recruited to at least partially offset a reduction in coronary blood flow; (4) less effective pressure-flow autoregulation; (5) the ability to downregulate its metabolic demand during coronary hypoperfusion and thereby maintain contractile function and energy stores; (6) a transmurally uniform reduction in myocardial perfusion in the presence of a hemodynamically significant epicardial coronary stenosis; (7) extensive collateral connections from the left coronary circulation; and (8) possible retrograde perfusion from the right ventricular cavity through the Thebesian veins. These differences promote the maintenance of right ventricular oxygen supply-demand balance and provide relative resistance to ischemia-induced contractile dysfunction and infarction, but they may be compromised during acute or chronic increases in right ventricle afterload resulting from pulmonary arterial hypertension. Contractile function of the thin-walled right ventricle is exquisitely sensitive to afterload. Acute increases in pulmonary arterial pressure reduce right ventricular stroke volume and, if sufficiently large and prolonged, result in right ventricular failure. Right ventricular ischemia plays a prominent role in these effects. The risk of right ventricular ischemia is also heightened during chronic elevations in right ventricular afterload because microvascular growth fails to match myocyte hypertrophy and because microvascular

  10. Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timmins, Rachel; Klein, Ran; Petryk, Julia

    Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress.more » Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision.« less

  11. Area at risk can be assessed by iodine-123-meta-iodobenzylguanidine single-photon emission computed tomography after myocardial infarction: a prospective study.

    PubMed

    Hedon, Christophe; Huet, Fabien; Ben Bouallegue, Fayçal; Vernhet, Hélène; Macia, Jean-Christophe; Cung, Thien-Tri; Leclercq, Florence; Cade, Stéphane; Cransac, Frédéric; Lattuca, Benoit; Vandenberghe, D'Arcy; Bourdon, Aurélie; Benkiran, Meriem; Vauchot, Fabien; Gervasoni, Richard; D'estanque, Emmanuel; Mariano-Goulart, Denis; Roubille, François

    2018-02-01

    Myocardial salvage is an important surrogate endpoint to estimate the impact of treatments in patients with ST-segment elevation myocardial infarction (STEMI). The aim of this study was to evaluate the correlation between cardiac sympathetic denervation area assessed by single-photon emission computed tomography (SPECT) using iodine-123-meta-iodobenzylguanidine (I-MIBG) and myocardial area at risk (AAR) assessed by cardiac magnetic resonance (CMR) (gold standard). A total of 35 postprimary reperfusion STEMI patients were enrolled prospectively to undergo SPECT using I-MIBG (evaluates cardiac sympathetic denervation) and thallium-201 (evaluates myocardial necrosis), and to undergo CMR imaging using T2-weighted spin-echo turbo inversion recovery for AAR and postgadolinium T1-weighted phase sensitive inversion recovery for scar assessment. I-MIBG imaging showed a wider denervated area (51.1±16.0% of left ventricular area) in comparison with the necrosis area on thallium-201 imaging (16.1±14.4% of left ventricular area, P<0.0001). CMR and SPECT provided similar evaluation of the transmural necrosis (P=0.10) with a good correlation (R=0.86, P<0.0001). AAR on CMR was not different compared with the denervated area (P=0.23) and was adequately correlated (R=0.56, P=0.0002). Myocardial salvage evaluated by SPECT imaging (mismatch denervated but viable myocardium) was significantly higher than by CMR (P=0.02). In patients with STEMI, I-MIBG SPECT, assessing cardiac sympathetic denervation may precisely evaluate the AAR, providing an alternative to CMR for AAR assessment.

  12. Cardiac PET perfusion tracers: current status and future directions.

    PubMed

    Maddahi, Jamshid; Packard, René R S

    2014-09-01

    PET myocardial perfusion imaging (MPI) is increasingly being used for noninvasive detection and evaluation of coronary artery disease. However, the widespread use of PET MPI has been limited by the shortcomings of the current PET perfusion tracers. The availability of these tracers is limited by the need for an onsite ((15)O water and (13)N ammonia) or nearby ((13)N ammonia) cyclotron or commitment to costly generators ((82)Rb). Owing to the short half-lives, such as 76 seconds for (82)Rb, 2.06 minutes for (15)O water, and 9.96 minutes for (13)N ammonia, their use in conjunction with treadmill exercise stress testing is either not possible ((82)Rb and (15)O water) or not practical ((13)N ammonia). Furthermore, the long positron range of (82)Rb makes image resolution suboptimal and its low myocardial extraction limits its defect resolution. In recent years, development of an (18)F-labeled PET perfusion tracer has gathered considerable interest. The longer half-life of (18)F (109 minutes) would make the tracer available as a unit dose from regional cyclotrons and allow use in conjunction with treadmill exercise testing. Furthermore, the short positron range of (18)F would result in better image resolution. Flurpiridaz F 18 is by far the most thoroughly studied in animal models and is the only (18)F-based PET MPI radiotracer currently undergoing clinical evaluation. Preclinical and clinical experience with Flurpiridaz F 18 demonstrated a high myocardial extraction fraction, high image and defect resolution, high myocardial uptake, slow myocardial clearance, and high myocardial-to-background contrast that was stable over time-important properties of an ideal PET MPI radiotracer. Preclinical data from other (18)F-labeled myocardial perfusion tracers are encouraging. Copyright © 2014. Published by Elsevier Inc.

  13. Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

    PubMed

    Srichai, Monvadi B; Lim, Ruth P; Lath, Narayan; Babb, James; Axel, Leon; Kim, Daniel

    2013-01-01

    We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (<30 days) troponin elevation greater than 2 times the upper limit of normal as the reference standard for acute myocardial injury. Of the 65 patients, there were 21 (32%) with acute myocardial injury. Image quality and artifact scores were significantly better with FSE-SPAIR compared with FSE-STIR (2.15 vs 2.68, P < 0.01; 2.62 vs 3.05, P < 0.01, respectively). The sensitivity, specificity, positive predictive value, and negative predictive value for acute myocardial injury were as follows: 29%, 93%, 67%, and 73% for FSE-SPAIR; 38%, 91%, 67%, and 75% for FSE-STIR; 71%, 98%, 94%, and 88% for clinical interpretation including LGE, T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence

  14. Dynamic susceptibility contrast-enhanced perfusion MR imaging at 1.5 T predicts final infarct size in a rat stroke model.

    PubMed

    Chen, Feng; Suzuki, Yasuhiro; Nagai, Nobuo; Peeters, Ronald; Marchal, Guy; Ni, Yicheng

    2005-01-30

    The purpose of the present animal experiment was to determine whether source images from dynamic susceptibility contrast-enhanced perfusion weighted imaging (DSC-PWI) at a 1.5T MR scanner, performed early after photochemically induced thrombosis (PIT) of cerebral middle artery (MCA), is feasible to predict final cerebral infarct size in a rat stroke model. Fifteen rats were subjected to PIT of proximal MCA. T2 weighted imaging (T2WI), diffusion-weighted imaging (DWI), and contrast-enhanced PWI were obtained at 1 h and 24 h after MCA occlusion. The relative lesion size (RLS) was defined as lesion volume/brain volume x 100% and measured for MR images, and compared with the final RLS on the gold standard triphenyl tetrazolium chloride (TTC) staining at 24 h. One hour after MCA occlusion, the RLS with DSC-PWI was 24.9 +/- 6.3%, which was significantly larger than 17.6 +/- 4.8% with DWI (P < 0.01). At 24 h, the final RLS on TTC was 24.3 +/- 4.8%, which was comparable to 25.1 +/- 3.5%, 24.6 +/- 3.6% and 27.9 +/- 6.8% with T2WI, DWI and DSC-PWI respectively (P > 0.05). The fact that at 1 h after MCA occlusion only the displayed perfusion deficit was similar to the final infarct size on TTC (P > 0.05) suggests that early source images from DSC-PWI at 1.5T MR scanner is feasible to noninvasively predict the final infarct size in rat models of stroke.

  15. Combined thallium-201 and dynamic iodine-123 iodophenylpentadecanoic acid single-photon emission computed tomography in patients after acute myocardial infarction with effective reperfusion.

    PubMed

    Richter, W S; Beckmann, S; Cordes, M; Schuppenhauer, T; Schartl, M; Munz, D L

    2000-12-01

    Considerable derangements of energy metabolism are to be expected during ischemia and reperfusion. In ischemic myocardium, the oxidative degradation of carbohydrates is shifted toward the anaerobic production of lactate and the oxidation of fatty acids is suppressed. The aim of this study was to examine the uptake and metabolism of iodine-123 (123I) iodophenylpentadecanoic acid (IPPA) in stunned myocardium. In 15 patients, SPECT with 201Tl and 123I IPPA as well as echocardiography with low-dose dobutamine stimulation were performed 12 +/- 5 days after myocardial infarction with reperfusion. Follow-up echocardiography was carried out 24 +/- 8 days later for documentation of functional improvement. Uptake of 201Tl and 123I IPPA were obtained in five left ventricular segments, and dynamic SPECT imaging was used for calculation of the fast and the slow components of the biexponential myocardial 123I IPPA clearance. Wall motion improved in 14 of 26 dysfunctional segments (54%). Stunned segments were characterized by a reduced 123I IPPA extraction, a shorter half-life of the fast, and a longer half-life of the slow clearance component. All parameters of the combined 201Tl/123I IPPA study predicted functional recovery with similar accuracies (area under the receiver operator characteristic curves between 0.68 and 0.76; p = NS). Analysis of 201Tl uptake alone could not predict functional recovery in this study. Stunned myocardium is characterized by a disturbance of fatty acid metabolism. For prediction of functional improvement, 123I IPPA imaging added significant diagnostic information.

  16. TH-CD-206-07: Determination of Patient-Specific Myocardial Mass at Risk Using Computed Tomography Angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hubbard, L; Ziemer, B; Malkasian, S

    Purpose: To evaluate the accuracy of a patient-specific coronary perfusion territory assignment algorithm that uses CT angiography (CTA) and a minimum-cost-path approach to assign coronary perfusion territories on a voxel-by-voxel basis for determination of myocardial mass at risk. Methods: Intravenous (IV) contrast (370 mg/mL iodine, 25 mL, 7 mL/s) was injected centrally into five swine (35–45 kg) and CTA was performed using a 320-slice CT scanner at 100 kVp and 200 mA. Additionally, a 4F catheter was advanced into the left anterior descending (LAD), left circumflex (LCX), and right coronary artery (RCA) and contrast (30 mg/mL iodine, 10 mL, 1.5more » mL/s) was directly injected into each coronary artery for isolation of reference coronary perfusion territories. Semiautomatic myocardial segmentation of the CTA data was then performed and the centerlines of the LAD, LCX, and RCA were digitally extracted through image processing. Individual coronary perfusion territories were then assigned using a minimum-cost-path approach, and were quantitatively compared to the reference coronary perfusion territories. Results: The results of the coronary perfusion territory assignment algorithm were in good agreement with the reference coronary perfusion territories. The average volumetric assignment error from mitral orifice to apex was 5.5 ± 1.1%, corresponding to 2.1 ± 0.7 grams of myocardial mass misassigned for each coronary perfusion territory. Conclusion: The results indicate that accurate coronary perfusion territory assignment is possible on a voxel-by-voxel basis using CTA data and an assignment algorithm based on a minimum-cost-path approach. Thus, the technique can potentially be used to accurately determine patient-specific myocardial mass at risk distal to a coronary stenosis, improving coronary lesion assessment and treatment. Conflict of Interest (only if applicable): Grant funding from Toshiba America Medical Systems.« less

  17. Radionuclide imaging of myocardial infarction using Tc-99m TBI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holman, B.L.; Campbell, S.; Kirshenbaum, J.M.

    The cationic complex Tc-99m t-butylisonitrile (TBI) concentrates in the myocardial tissue of several animal species. Its myocardial distribution is proportional to blood flow both in zones of ischemia and in normal myocardium at rest. Planar, tomographic, and gated myocardial images have been obtained using Tc-99m TBI in the human. The authors investigated the potential application of Tc-99m TBI imaging to detect and localize myocardial infarction. Four subjects without clinical evidence of cardiovascular disease and five patients with ECG evidence of previous myocardial infarction were studied. Tc-99m TBI (10mCi) was injected intravenously with the patient in a resting state with planarmore » imaging in the anterior, 30 and 70 degree LAO projections beginning one hr after injection. The distribution of the tracer was homogeneous throughout the left ventricular wall in the normal subjects. Regional perfusion defects were present in 4/5 of the patients with myocardial infarction. Location of the defects corresponded to the location of the infarct using ECG criteria (2 inferoposterior and 2 anterior). The patient in whom the Tc-99m TBI image appeared normal had sustained a subendocardial myocardial infarct which could not be localized by ECG; the other 4 pts had transmural infarcts. Anterior and 30 degree LAO images were of excellent quality in all cases; there was overlap of the liver on the inferior wall of the left ventricle on the 70 degree LAO views. The authors conclude that accurate perfusion imaging may be possible using Tc-99m TBI in patients with transmural myocardial infarction.« less

  18. Myocardial perfusion and oxidative stress after 21% vs. 100% oxygen ventilation and uninterrupted chest compressions in severely asphyxiated piglets.

    PubMed

    Solevåg, Anne Lee; Schmölzer, Georg M; O'Reilly, Megan; Lu, Min; Lee, Tze-Fun; Hornberger, Lisa K; Nakstad, Britt; Cheung, Po-Yin

    2016-09-01

    Despite the minimal evidence, neonatal resuscitation guidelines recommend using 100% oxygen when chest compressions (CC) are needed. Uninterrupted CC in adult cardiopulmonary resuscitation (CPR) may improve CPR hemodynamics. We aimed to examine 21% oxygen (air) vs. 100% oxygen in 3:1 CC:ventilation (C:V) CPR or continuous CC with asynchronous ventilation (CCaV) in asphyxiated newborn piglets following cardiac arrest. Piglets (1-3 days old) were progressively asphyxiated until cardiac arrest and randomized to 4 experimental groups (n=8 each): air and 3:1 C:V CPR, 100% oxygen and 3:1 C:V CPR, air and CCaV, or 100% oxygen and CCaV. Time to return of spontaneous circulation (ROSC), mortality, and clinical and biochemical parameters were compared between groups. We used echocardiography to measure left ventricular (LV) stroke volume at baseline, at 30min and 4h after ROSC. Left common carotid artery blood pressure was measured continuously. Time to ROSC (heart rate ≥100min(-1)) ranged from 75 to 592s and mortality 50-75%, with no differences between groups. Resuscitation with air was associated with higher LV stroke volume after ROSC and less myocardial oxidative stress compared to 100% oxygen groups. CCaV was associated with lower mean arterial blood pressure after ROSC and higher myocardial lactate than those of 3:1 C:V CPR. In neonatal asphyxia-induced cardiac arrest, using air during CC may reduce myocardial oxidative stress and improve cardiac function compared to 100% oxygen. Although overall recovery may be similar, CCaV may impair tissue perfusion compared to 3:1 C:V CPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Positron emission tomography for the assessment of myocardial viability: an evidence-based analysis.

    PubMed

    2010-01-01

    myocardial viability. Intravenous contrast agents, which are high molecular weight inert gas microbubbles that act like red blood cells in the vascular space, can be used during echocardiography to assess myocardial viability. These agents allow for the assessment of myocardial blood flow (perfusion) and contractile function (as described above), as well as the simultaneous assessment of perfusion to make it possible to distinguish between stunned and hibernating myocardium. SPECT: SPECT can be performed using thallium-201 (Tl-201), a potassium analogue, or technetium-99 m labelled tracers. When Tl-201 is injected intravenously into a patient, it is taken up by the myocardial cells through regional perfusion, and Tl-201 is retained in the cell due to sodium/potassium ATPase pumps in the myocyte membrane. The stress-redistribution-reinjection protocol involves three sets of images. The first two image sets (taken immediately after stress and then three to four hours after stress) identify perfusion defects that may represent scar tissue or viable tissue that is severely hypoperfused. The third set of images is taken a few minutes after the re-injection of Tl-201 and after the second set of images is completed. These re-injection images identify viable tissue if the defects exhibit significant fill-in (> 10% increase in tracer uptake) on the re-injection images. The other common Tl-201 viability imaging protocol, rest-redistribution, involves SPECT imaging performed at rest five minutes after Tl-201 is injected and again three to four hours later. Viable tissue is identified if the delayed images exhibit significant fill-in of defects identified in the initial scans (> 10% increase in uptake) or if defects are fixed but the tracer activity is greater than 50%. There are two technetium-99 m tracers: sestamibi (MIBI) and tetrofosmin. The uptake and retention of these tracers is dependent on regional perfusion and the integrity of cellular membranes. Viability is assessed using

  20. Low-dose dynamic myocardial perfusion CT image reconstruction using pre-contrast normal-dose CT scan induced structure tensor total variation regularization

    NASA Astrophysics Data System (ADS)

    Gong, Changfei; Han, Ce; Gan, Guanghui; Deng, Zhenxiang; Zhou, Yongqiang; Yi, Jinling; Zheng, Xiaomin; Xie, Congying; Jin, Xiance

    2017-04-01

    Dynamic myocardial perfusion CT (DMP-CT) imaging provides quantitative functional information for diagnosis and risk stratification of coronary artery disease by calculating myocardial perfusion hemodynamic parameter (MPHP) maps. However, the level of radiation delivered by dynamic sequential scan protocol can be potentially high. The purpose of this work is to develop a pre-contrast normal-dose scan induced structure tensor total variation regularization based on the penalized weighted least-squares (PWLS) criteria to improve the image quality of DMP-CT with a low-mAs CT acquisition. For simplicity, the present approach was termed as ‘PWLS-ndiSTV’. Specifically, the ndiSTV regularization takes into account the spatial-temporal structure information of DMP-CT data and further exploits the higher order derivatives of the objective images to enhance denoising performance. Subsequently, an effective optimization algorithm based on the split-Bregman approach was adopted to minimize the associative objective function. Evaluations with modified dynamic XCAT phantom and preclinical porcine datasets have demonstrated that the proposed PWLS-ndiSTV approach can achieve promising gains over other existing approaches in terms of noise-induced artifacts mitigation, edge details preservation, and accurate MPHP maps calculation.

  1. Automatic detection of left and right ventricles from CTA enables efficient alignment of anatomy with myocardial perfusion data.

    PubMed

    Piccinelli, Marina; Faber, Tracy L; Arepalli, Chesnal D; Appia, Vikram; Vinten-Johansen, Jakob; Schmarkey, Susan L; Folks, Russell D; Garcia, Ernest V; Yezzi, Anthony

    2014-02-01

    Accurate alignment between cardiac CT angiographic studies (CTA) and nuclear perfusion images is crucial for improved diagnosis of coronary artery disease. This study evaluated in an animal model the accuracy of a CTA fully automated biventricular segmentation algorithm, a necessary step for automatic and thus efficient PET/CT alignment. Twelve pigs with acute infarcts were imaged using Rb-82 PET and 64-slice CTA. Post-mortem myocardium mass measurements were obtained. Endocardial and epicardial myocardial boundaries were manually and automatically detected on the CTA and both segmentations used to perform PET/CT alignment. To assess the segmentation performance, image-based myocardial masses were compared to experimental data; the hand-traced profiles were used as a reference standard to assess the global and slice-by-slice robustness of the automated algorithm in extracting myocardium, LV, and RV. Mean distances between the automated and the manual 3D segmented surfaces were computed. Finally, differences in rotations and translations between the manual and automatic surfaces were estimated post-PET/CT alignment. The largest, smallest, and median distances between interactive and automatic surfaces averaged 1.2 ± 2.1, 0.2 ± 1.6, and 0.7 ± 1.9 mm. The average angular and translational differences in CT/PET alignments were 0.4°, -0.6°, and -2.3° about x, y, and z axes, and 1.8, -2.1, and 2.0 mm in x, y, and z directions. Our automatic myocardial boundary detection algorithm creates surfaces from CTA that are similar in accuracy and provide similar alignments with PET as those obtained from interactive tracing. Specific difficulties in a reliable segmentation of the apex and base regions will require further improvements in the automated technique.

  2. Optimization of a simultaneous dual-isotope 201Tl/123I-MIBG myocardial SPECT imaging protocol with a CZT camera for trigger zone assessment after myocardial infarction for routine clinical settings: Are delayed acquisition and scatter correction necessary?

    PubMed

    D'estanque, Emmanuel; Hedon, Christophe; Lattuca, Benoît; Bourdon, Aurélie; Benkiran, Meriem; Verd, Aurélie; Roubille, François; Mariano-Goulart, Denis

    2017-08-01

    Dual-isotope 201 Tl/ 123 I-MIBG SPECT can assess trigger zones (dysfunctions in the autonomic nervous system located in areas of viable myocardium) that are substrate for ventricular arrhythmias after STEMI. This study evaluated the necessity of delayed acquisition and scatter correction for dual-isotope 201 Tl/ 123 I-MIBG SPECT studies with a CZT camera to identify trigger zones after revascularization in patients with STEMI in routine clinical settings. Sixty-nine patients were prospectively enrolled after revascularization to undergo 201 Tl/ 123 I-MIBG SPECT using a CZT camera (Discovery NM 530c, GE). The first acquisition was a single thallium study (before MIBG administration); the second and the third were early and late dual-isotope studies. We compared the scatter-uncorrected and scatter-corrected (TEW method) thallium studies with the results of magnetic resonance imaging or transthoracic echography (reference standard) to diagnose myocardial necrosis. Summed rest scores (SRS) were significantly higher in the delayed MIBG studies than the early MIBG studies. SRS and necrosis surface were significantly higher in the delayed thallium studies with scatter correction than without scatter correction, leading to less trigger zone diagnosis for the scatter-corrected studies. Compared with the scatter-uncorrected studies, the late thallium scatter-corrected studies provided the best diagnostic values for myocardial necrosis assessment. Delayed acquisitions and scatter-corrected dual-isotope 201 Tl/ 123 I-MIBG SPECT acquisitions provide an improved evaluation of trigger zones in routine clinical settings after revascularization for STEMI.

  3. 40 CFR 246.201-1 - Requirement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Requirement. 246.201-1 Section 246.201-1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES SOURCE SEPARATION FOR MATERIALS RECOVERY GUIDELINES Requirements and Recommended Procedures § 246.201-1 Requirement...

  4. 40 CFR 246.201-1 - Requirement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Requirement. 246.201-1 Section 246.201-1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES SOURCE SEPARATION FOR MATERIALS RECOVERY GUIDELINES Requirements and Recommended Procedures § 246.201-1 Requirement...

  5. 40 CFR 246.201-1 - Requirement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Requirement. 246.201-1 Section 246.201-1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES SOURCE SEPARATION FOR MATERIALS RECOVERY GUIDELINES Requirements and Recommended Procedures § 246.201-1 Requirement...

  6. DNA double-strand breaks in blood lymphocytes induced by two-day 99mTc-MIBI myocardial perfusion scintigraphy.

    PubMed

    Rief, Matthias; Hartmann, Lisa; Geisel, Dominik; Richter, Felicitas; Brenner, Winfried; Dewey, Marc

    2018-07-01

    To investigate DNA double-strand breaks (DSBs) in blood lymphocytes induced by two-day 99m Tc-MIBI myocardial perfusion scintigraphy (MPS) using y-H2AX immunofluorescence microscopy and to correlate the results with 99m Tc activity in blood samples. Eleven patients who underwent two-day MPS were included. DSB blood sampling was performed before and 5min, 1h and 24h after the first and second radiotracer injections. 99m Tc activity was measured in each blood sample. For immunofluorescence microscopy, distinct foci representing DSBs were quantified in lymphocytes after staining for the phosphorylated histone variant y-H2AX. The 99m Tc-MIBI activity measured on days one and two was similar (254±25 and 258±27 MBq; p=0.594). Compared with baseline DSB foci (0.09±0.05/cell), a significant increase was found at 5min (0.19±0.04/cell) and 1h (0.18±0.04/cell) after the first injection and at 5min and 1h after the second injection (0.21±0.03 and 0.19±0.04/cell, respectively; p=0.003 for both). At 24h after the first and second injections, the number of DSB foci had returned to baseline (0.06±0.02 and 0.12±0.05/cell, respectively). 99m Tc activity levels in peripheral blood samples correlated well with DSB counts (r=0.451). DSB counts reflect 99m Tc-MIBI activity after injection for two-day MPS, and might allow individual monitoring of biological effects of cardiac nuclear imaging. • Myocardial perfusion scintigraphy using 99m Tc induces time-dependent double-strand breaks (DSBs) • γ-H2AX immunofluorescence microscopy shows DSB as an early response to radiotracer injection • Activity measurements of 99m Tc correlate well with detected DSB • DSB foci induced by 99m Tc return to baseline 24h after radiotracer injection.

  7. Dynamic CT myocardial perfusion imaging: detection of ischemia in a porcine model with FFR verification

    NASA Astrophysics Data System (ADS)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    Dynamic cardiac CT perfusion (CTP) is a high resolution, non-invasive technique for assessing myocardial blood ow (MBF), which in concert with coronary CT angiography enable CT to provide a unique, comprehensive, fast analysis of both coronary anatomy and functional ow. We assessed perfusion in a porcine model with and without coronary occlusion. To induce occlusion, each animal underwent left anterior descending (LAD) stent implantation and angioplasty balloon insertion. Normal ow condition was obtained with balloon completely de ated. Partial occlusion was induced by balloon in ation against the stent with FFR used to assess the extent of occlusion. Prospective ECG-triggered partial scan images were acquired at end systole (45% R-R) using a multi-detector CT (MDCT) scanner. Images were reconstructed using FBP and a hybrid iterative reconstruction (iDose4, Philips Healthcare). Processing included: beam hardening (BH) correction, registration of image volumes using 3D cubic B-spline normalized mutual-information, and spatio-temporal bilateral ltering to reduce partial scan artifacts and noise variation. Absolute blood ow was calculated with a deconvolutionbased approach using singular value decomposition (SVD). Arterial input function was estimated from the left ventricle (LV) cavity. Regions of interest (ROIs) were identi ed in healthy and ischemic myocardium and compared in normal and occluded conditions. Under-perfusion was detected in the correct LAD territory and ow reduction agreed well with FFR measurements. Flow was reduced, on average, in LAD territories by 54%.

  8. 16 CFR 20.1 - Deception generally.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Deception generally. 20.1 Section 20.1 Commercial Practices FEDERAL TRADE COMMISSION GUIDES AND TRADE PRACTICE RULES GUIDES FOR THE REBUILT, RECONDITIONED AND OTHER USED AUTOMOBILE PARTS INDUSTRY § 20.1 Deception generally. (a) It is unfair or deceptive...

  9. 16 CFR 20.1 - Deception generally.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Deception generally. 20.1 Section 20.1 Commercial Practices FEDERAL TRADE COMMISSION GUIDES AND TRADE PRACTICE RULES GUIDES FOR THE REBUILT, RECONDITIONED AND OTHER USED AUTOMOBILE PARTS INDUSTRY § 20.1 Deception generally. (a) It is unfair or deceptive...

  10. 16 CFR 20.1 - Deception generally.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Deception generally. 20.1 Section 20.1 Commercial Practices FEDERAL TRADE COMMISSION GUIDES AND TRADE PRACTICE RULES GUIDES FOR THE REBUILT, RECONDITIONED AND OTHER USED AUTOMOBILE PARTS INDUSTRY § 20.1 Deception generally. (a) It is unfair or deceptive...

  11. 16 CFR 20.1 - Deception generally.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Deception generally. 20.1 Section 20.1 Commercial Practices FEDERAL TRADE COMMISSION GUIDES AND TRADE PRACTICE RULES GUIDES FOR THE REBUILT, RECONDITIONED AND OTHER USED AUTOMOBILE PARTS INDUSTRY § 20.1 Deception generally. (a) It is unfair or deceptive...

  12. 16 CFR 20.1 - Deception generally.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Deception generally. 20.1 Section 20.1 Commercial Practices FEDERAL TRADE COMMISSION GUIDES AND TRADE PRACTICE RULES GUIDES FOR THE REBUILT, RECONDITIONED AND OTHER USED AUTOMOBILE PARTS INDUSTRY § 20.1 Deception generally. (a) It is unfair or deceptive...

  13. In Search of the Optimal Heart Perfusion Ultrasound Imaging Platform.

    PubMed

    Grishenkov, Dmitry; Gonon, Adrian; Janerot-Sjoberg, Birgitta

    2015-09-01

    Quantification of myocardial perfusion by contrast echocardiography remains a challenge. Existing imaging phantoms used to evaluate the performance of ultrasound scanners do not comply with perfusion basics in the myocardium, where perfusion and motion are inherently coupled. To contribute toward an improvement, we developed a contrast echocardiographic perfusion imaging platform based on an isolated rat heart coupled to an ultrasound scanner. Perfusion was assessed by using 3 different types of contrast agents: dextran-based Promiten (Meda AB, Solna, Sweden), phospholipid-shelled SonoVue (Bracco Diagnostics, Inc, Princeton, NJ), and polymer-shelled MB-pH5-RT, developed in-house. The myocardial video intensity was monitored over time from contrast agent administration to peak, and 2 characteristic constants were calculated by using an exponential fit: A, representing capillary volume; and β, representing inflow velocity. Acquired experimental evidence demonstrates that the application of all 3 contrast agents allows sonographic estimation of myocardial perfusion in the isolated rat heart. Video intensity maps show that an increase in contrast concentration increases the late-plateau values, A, mimicking increased capillary volume. Estimated values of the flow, proportional to A × β, increase when the pressure of the perfusate column increases from 80 to 110 cm of water. This finding is in agreement with the true values of the coronary flow increase measured by a flowmeter attached to the aortic cannula. The contrast echocardiographic perfusion imaging platform described holds promise for standardized evaluation and optimization of contrast perfusion ultrasound imaging in which real-time inflow curves at low acoustic power semiquantitatively reflect coronary flow. © 2015 by the American Institute of Ultrasound in Medicine.

  14. Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks

    NASA Astrophysics Data System (ADS)

    Ghaly, Michael; Du, Yong; Links, Jonathan M.; Frey, Eric C.

    2016-03-01

    In SPECT imaging, collimators are a major factor limiting image quality and largely determine the noise and resolution of SPECT images. In this paper, we seek the collimator with the optimal tradeoff between image noise and resolution with respect to performance on two tasks related to myocardial perfusion SPECT: perfusion defect detection and joint detection and localization. We used the Ideal Observer (IO) operating on realistic background-known-statistically (BKS) and signal-known-exactly (SKE) data. The areas under the receiver operating characteristic (ROC) and localization ROC (LROC) curves (AUCd, AUCd+l), respectively, were used as the figures of merit for both tasks. We used a previously developed population of 54 phantoms based on the eXtended Cardiac Torso Phantom (XCAT) that included variations in gender, body size, heart size and subcutaneous adipose tissue level. For each phantom, organ uptakes were varied randomly based on distributions observed in patient data. We simulated perfusion defects at six different locations with extents and severities of 10% and 25%, respectively, which represented challenging but clinically relevant defects. The extent and severity are, respectively, the perfusion defect’s fraction of the myocardial volume and reduction of uptake relative to the normal myocardium. Projection data were generated using an analytical projector that modeled attenuation, scatter, and collimator-detector response effects, a 9% energy resolution at 140 keV, and a 4 mm full-width at half maximum (FWHM) intrinsic spatial resolution. We investigated a family of eight parallel-hole collimators that spanned a large range of sensitivity-resolution tradeoffs. For each collimator and defect location, the IO test statistics were computed using a Markov Chain Monte Carlo (MCMC) method for an ensemble of 540 pairs of defect-present and -absent images that included the aforementioned anatomical and uptake variability. Sets of test statistics were

  15. Prognostic impact of location and extent of vessel-related ischemia at myocardial perfusion scintigraphy in patients with or at risk for coronary artery disease.

    PubMed

    Nudi, Francesco; Schillaci, Orazio; Neri, Giandomenico; Pinto, Annamaria; Procaccini, Enrica; Vetere, Maurizio; Frati, Giacomo; Tomai, Fabrizio; Biondi-Zoccai, Giuseppe

    2016-04-01

    Myocardial perfusion scintigraphy (MPS) has an established diagnostic and prognostic role in patients with or at risk for coronary artery disease, with ischemia severity and extent having already been identified as key predictors. Whether this is affected by the location of myocardial ischemia is uncertain. We aimed at comparing the prognostic outlook of patients undergoing MPS according to the site of ischemia. Our institutional database was queried for subjects undergoing MPS, without myocardial necrosis or recent revascularization. We focused on the prognostic impact of location of vessel-related ischemia (VRI) at MPS, distinguishing four mutually exclusive groups: single-VRI involving left anterior descending (LAD), single-VRI not involving LAD, multi-VRI involving LAD, and multi-VRI not involving LAD. The primary outcome was the long-term (>1 year) rate of death or myocardial infarction (D/MI). A total of 13,254 patients were included. Moderate or severe VRI occurred in 2,627 (20%) patients. Clinical outcomes were significantly different among the groups of patients with moderate or severe VRI, including death, cardiac death, non-fatal myocardial infarction or their composites (overall P < .001). Specifically, and excluding subjects undergoing revascularization as first follow-up event, D/MI occurred in 8.4% of patients with single-VRI involving LAD, 5.5% of subjects with single-VRI not involving LAD, 16.5% of those with multi-VRI involving LAD, and 7.3% of patients with multi-VRI not involving LAD (overall P < .001). Even at incremental multivariable Cox proportional analysis, hierarchical VRI was independently associated with an increased risk of D/MI [hazard ratio = 1.17 (1.04-1.08) for each class increment, P = .010]. Location and extent of myocardial ischemia at MPS according to the VRI concept have a hierarchical predictive impact, with multi-VRI involving LAD being significantly and independently more prognostically ominous than other types of VRI.

  16. 47 CFR 20.1 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Purpose. 20.1 Section 20.1 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES COMMERCIAL MOBILE RADIO SERVICES... to commercial mobile radio service providers. ...

  17. The clinical implications of myocardial perfusion abnormalities in patients with esophageal or lung cancer after chemoradiation therapy.

    PubMed

    Gayed, Isis; Gohar, Salman; Liao, Zhongxing; McAleer, Mary; Bassett, Roland; Yusuf, Syed Wamique

    2009-06-01

    This study aims to identify the clinical implications of myocardial perfusion defects after chemoradiation therapy (CRT) in patients with esophageal and lung cancer. We retrospectively compared myocardial perfusion imaging (MPI) results before and after CRT in 16 patients with esophageal cancer and 24 patients with lung cancer. New MPI defects in the radiation therapy (RT) fields were considered related to RT. Follow-up to evaluate for cardiac complications and their relation with the results of MPI was performed. Statistical analysis identified predictors of cardiac morbidities. Eleven females and twenty nine males at a mean age of 66.7 years were included. Five patients (31%) with esophageal cancer and seven patients (29%) with lung cancer developed myocardial ischemia in the RT field at mean intervals of 7.0 and 8.4 months after RT. The patients were followed-up for mean intervals of 15 and 23 months in the esophageal and lung cancer groups, respectively. Seven patients in each of the esophageal (44%) and lung (29%) cancer patients (P = 0.5) developed cardiac complications of which one patient with esophageal cancer died of complete heart block. Six out of the fourteen patients (43%) with cardiac complication had new ischemia on MPI after CRT of which only one developed angina. The remaining eight patients with cardiac complications had normal MPI results. MPI result was not a statistically significant predictor of future cardiac complications after CRT. A history of congestive heart failure (CHF) (P = 0.003) or arrhythmia (P = 0.003) is a significant predictor of cardiac morbidity after CRT in univariate analysis but marginal predictors when multivariate analysis was performed (P = 0.06 and 0.06 for CHF and arrhythmia, respectively). Cardiac complications after CRT are more common in esophageal than lung cancer patients but the difference is not statistically significant. MPI abnormalities are frequently seen after CRT but are not predictive of future cardiac

  18. Microvascular autonomic dysfunction may justify false-positive stress myocardial perfusion imaging in patients with liver cirrhosis undergoing liver transplantation.

    PubMed

    Senzolo, M; Bassanello, M; Graziotto, A; Zucchetta, P; Cillo, U; Maraglino, G; Loreno, M; Bellotto, F; Davià, G; Burra, P

    2008-01-01

    Up to 15% of liver transplant candidates have asymptomatic coronary artery diseases, which increase the risk of cardiac complications during and after transplantation. The aim of this study was to prospectively investigate the usefulness of an integrated cardiological approach in cirrhotic patients undergoing liver transplantation. Twenty-four consecutive patients undergoing evaluation for liver transplantation were studied by assessing risk factors for coronary artery diseases, electrocardiogram with QTc interval determination, chest X-ray, echocardiography, 24-hour Holter monitor, myocardial perfusion scintigraphy (99mTc)MIBI-GSPECT at rest and after dipyridamole infusion. Cardiac (123)I-metaiodobenzylguanidine (MIBG) scan and coronarography were performed in patients with myocardial perfusion defects. Twenty three of 24 patients underwent successful liver transplantation; one patient died on the waiting list. Before liver transplantation, 29% of patients were diabetic and 41% were smokers. Eleven of 24 patients had a prolonged QTc interval, and 3/24 had positive myocardioscintigraphy after dipyridamole infusion: in two coronarography was negative, while the (123)I-MIBG washout was altered. No cardiac events were recorded during the short-and long-term follow-up after surgery. Predictive value of positive cardiac (99mTc)MIBI-GSPECT in patients with liver cirrhosis is low, and this may be due to alterations of cardiac microvascular tone as showed by cardiac (123)I-MIBG scan.

  19. Detailing magnetic field strength dependence and segmental artifact distribution of myocardial effective transverse relaxation rate at 1.5, 3.0, and 7.0 T.

    PubMed

    Meloni, Antonella; Hezel, Fabian; Positano, Vincenzo; Keilberg, Petra; Pepe, Alessia; Lombardi, Massimo; Niendorf, Thoralf

    2014-06-01

    Realizing the challenges and opportunities of effective transverse relaxation rate (R2 *) mapping at high and ultrahigh fields, this work examines magnetic field strength (B0 ) dependence and segmental artifact distribution of myocardial R2 * at 1.5, 3.0, and 7.0 T. Healthy subjects were considered. Three short-axis views of the left ventricle were examined. R2 * was calculated for 16 standard myocardial segments. Global and mid-septum R2 * were determined. For each segment, an artifactual factor was estimated as the deviation of segmental from global R2 * value. The global artifactual factor was significantly enlarged at 7.0 T versus 1.5 T (P = 0.010) but not versus 3.0 T. At 7.0 T, the most severe susceptibility artifacts were detected in the inferior lateral wall. The mid-septum showed minor artifactual factors at 7.0 T, similar to those at 1.5 and 3.0 T. Mean R2 * increased linearly with the field strength, with larger changes for global heart R2 * values. At 7.0 T, segmental heart R2 * analysis is challenging due to macroscopic susceptibility artifacts induced by the heart-lung interface and the posterior vein. Myocardial R2 * depends linearly on the magnetic field strength. The increased R2 * sensitivity at 7.0 T might offer means for susceptibility-weighted and oxygenation level-dependent MR imaging of the myocardium. Copyright © 2013 Wiley Periodicals, Inc.

  20. Effect of the prosthetic group on the pharmacologic properties of 18F-labeled rhodamine B, a potential myocardial perfusion agent for positron emission tomography (PET).

    PubMed

    Bartholomä, Mark D; Gottumukkala, Vijay; Zhang, Shaohui; Baker, Amanda; Dunning, Patricia; Fahey, Frederic H; Treves, S Ted; Packard, Alan B

    2012-12-27

    We recently reported the development of the 2-[(18)F]fluoroethyl ester of rhodamine B as a potential positron emission tomography (PET) tracer for myocardial perfusion imaging. This compound, which was prepared using a [(18)F]fluoroethyl prosthetic group, has significant uptake in the myocardium in rats but also demonstrates relatively high liver uptake and is rapidly hydrolyzed in vivo in mice. We have now prepared (18)F-labeled rhodamine B using three additional prosthetic groups (propyl, diethylene glycol, and triethylene glycol) and found that the prosthetic group has a significant effect on the in vitro and in vivo properties of these compounds. Of the esters prepared to date, the diethylene glycol ester is superior in terms of in vitro stability and pharmacokinetics. These observations suggest that the prosthetic group plays a significant role in determining the pharmacological properties of (18)F-labeled compounds. They also support the value of continued investigation of (18)F-labeled rhodamines as PET radiopharmaceuticals for myocardial perfusion imaging.

  1. Radionuclide imaging in myocardial sarcoidosis. Demonstration of myocardial uptake of /sup 99m/Tc pyrophosphate and gallium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forman, M.B.; Sandler, M.P.; Sacks, G.A.

    1983-03-01

    A patient had severe congestive cardiomyopathy secondary to myocardial sarcoidosis. The clinical diagnosis was confirmed by radionuclide ventriculography, /sup 201/Tl, /sup 67/Ga, and /sup 99m/Tc pyrophosphate (TcPYP) scintigraphy. Myocardial TcPYP uptake has not been reported previously in sarcoidosis. In this patient, TcPYP was as useful as gallium scanning and thallium imaging in documenting the myocardial process.

  2. Myocardial effective transverse relaxation time T2* Correlates with left ventricular wall thickness: A 7.0 T MRI study.

    PubMed

    Huelnhagen, Till; Hezel, Fabian; Serradas Duarte, Teresa; Pohlmann, Andreas; Oezerdem, Celal; Flemming, Bert; Seeliger, Erdmann; Prothmann, Marcel; Schulz-Menger, Jeanette; Niendorf, Thoralf

    2017-06-01

    Myocardial effective relaxation time T2* is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence T2*. To this end, this study investigates the relationship between T2* and cardiac macromorphology given by left ventricular (LV) wall thickness and left ventricular radius, and provides interpretation of the results in the physiological context. High spatio-temporally resolved myocardial CINE T2* mapping was performed in 10 healthy volunteers using a 7.0 Tesla (T) full-body MRI system. Ventricular septal wall thickness, left ventricular inner radius, and T2* were analyzed. Macroscopic magnetic field changes were elucidated using cardiac phase-resolved magnetic field maps. Ventricular septal T2* changes periodically over the cardiac cycle, increasing in systole and decreasing in diastole. Ventricular septal wall thickness and T2* showed a significant positive correlation, whereas the inner LV radius and T2* were negatively correlated. The effect of macroscopic magnetic field gradients on T2* can be considered minor in the ventricular septum. Our findings suggest that myocardial T2* is related to tissue blood volume fraction. Temporally resolved T2* mapping could be beneficial for myocardial tissue characterization and for understanding cardiac (patho)physiology in vivo. Magn Reson Med 77:2381-2389, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  3. Progressive impairment of regional myocardial perfusion after initial restoration of postischemic blood flow.

    PubMed

    Ambrosio, G; Weisman, H F; Mannisi, J A; Becker, L C

    1989-12-01

    The "no-reflow" phenomenon, the occurrence of areas with very low flow in hearts reperfused after ischemia, is thought to be largely established at the time of reperfusion as a result of microvascular damage induced by ischemia. In the present study we sought to determine whether additional impairment of tissue perfusion might also occur during the course of reperfusion. Open-chest dogs were subjected to 90 minutes of left circumflex coronary artery occlusion and reperfused for 2 minutes (n = 7) or 3.5 hours (n = 8). Myocardial perfusion was visualized in left ventricular slices following in vivo injection of the fluorescent dye thioflavin-S just before killing. The area of impaired perfusion (absent thioflavin) averaged 9.5 +/- 3.0% of the risk region in dogs reperfused for 2 minutes, whereas it was nearly three times as large in dogs reperfused for 3.5 hours (25.9 +/- 8.2% of the risk region, p less than 0.05). Serial measurements of flow by microspheres during reperfusion demonstrated zones within the postischemic myocardium that were hyperemic 2 minutes after reperfusion, with adequate flow still present at 30 minutes, but with a subsequent marked fall in perfusion. After 3.5 hours these areas showed negligible flow (0.13 +/- 0.3 ml/min/g) and no thioflavin uptake. Tissue samples showing postischemic impairment in perfusion has received virtually no collateral flow during ischemia (less than 0.01 ml/min/g), whereas collateral flow was significantly higher in adjacent thioflavin-positive zones (0.04 +/- 0.01 ml/min/g in endocardial samples and 0.07 +/- 0.02 ml/min/g in samples from the midmyocardium, p less than 0.001 vs. thioflavin-negative areas). Areas that showed late impairment of flow invariably demonstrated contraction band necrosis, which contrasted with the pattern of coagulation necrosis observed in areas of "true" (i.e., immediate) no-reflow. Intracapillary erythrocyte stasis and marked intravascular neutrophil accumulation (to levels greater than 20

  4. Early changes in myocardial repolarization and coronary perfusion after cardiopulmonary bypass surgery for ASD repair in children.

    PubMed

    Aburawi, Elhadi H; Souid, Abdul-Kader; Liuba, Petru; Zoubeidi, Taoufik; Pesonen, Erkki

    2013-09-10

    In adults, impaired myocardial repolarization and increased risk of arrhythmia are known consequences of open heart surgery. Little is known, however, about post-operative consequences of cardiopulmonary bypass surgery in children. The aim of this study was to assess ventricular repolarization and coronary perfusion after bypass surgery for atrial septal defect (ASD) repair in children. Twelve patients with ASD were assessed one day before and 5-6 days after ASD repair. Myocardial repolarization (corrected QT interval, QTc, QT dispersion, QTd, and PQ interval) was determined on 12-lead electrocardiograms. Coronary flow in proximal left anterior descending artery (peak flow velocity in diastole, PFVd) was assessed by transthoracic Doppler echocardiography. Ten of the 12 (83%) children had normal myocardial repolarization before and after surgery. After surgery, QTc increased 1-9% in 5 (42%) patients, decreased 2-11% in 5 (42%) patients and did not change in 2 (16%) patients. Post-op QTc positively correlated with bypass time (R=0.686, p=0.014) and changes in PFVd (R=0.741, p=0.006). After surgery, QTd increased 33-67% in 4 (33%) patients, decreased 25-50% in 6 patients (50%) and did not change in 2 (16%) patients. After surgery, PQ interval increased 5-30% in 4 (33%) patients, decreased 4-29% in 6 (50%) patients and did not change in 1 (8%) patient. Post-op PQ positively correlated with bypass time (R=0.636, p=0.027). As previously reported, PFVd significantly increased after surgery (p<0.001). Changes in QTc, PQ and PFVd are common in young children undergoing surgery for ASD repair. Post-op QTc significantly correlates with bypass time, suggesting prolonged cardiopulmonary bypass may impair ventricular repolarization. Post-op QTc significantly correlates with PFVd changes, suggesting increased coronary flow may also impair ventricular repolarization. The clinical significance and reversibility of these alternations require further investigations.

  5. Value of automatic patient motion detection and correction in myocardial perfusion imaging using a CZT-based SPECT camera.

    PubMed

    van Dijk, Joris D; van Dalen, Jorn A; Mouden, Mohamed; Ottervanger, Jan Paul; Knollema, Siert; Slump, Cornelis H; Jager, Pieter L

    2018-04-01

    Correction of motion has become feasible on cadmium-zinc-telluride (CZT)-based SPECT cameras during myocardial perfusion imaging (MPI). Our aim was to quantify the motion and to determine the value of automatic correction using commercially available software. We retrospectively included 83 consecutive patients who underwent stress-rest MPI CZT-SPECT and invasive fractional flow reserve (FFR) measurement. Eight-minute stress acquisitions were reformatted into 1.0- and 20-second bins to detect respiratory motion (RM) and patient motion (PM), respectively. RM and PM were quantified and scans were automatically corrected. Total perfusion deficit (TPD) and SPECT interpretation-normal, equivocal, or abnormal-were compared between the noncorrected and corrected scans. Scans with a changed SPECT interpretation were compared with FFR, the reference standard. Average RM was 2.5 ± 0.4 mm and maximal PM was 4.5 ± 1.3 mm. RM correction influenced the diagnostic outcomes in two patients based on TPD changes ≥7% and in nine patients based on changed visual interpretation. In only four of these patients, the changed SPECT interpretation corresponded with FFR measurements. Correction for PM did not influence the diagnostic outcomes. Respiratory motion and patient motion were small. Motion correction did not appear to improve the diagnostic outcome and, hence, the added value seems limited in MPI using CZT-based SPECT cameras.

  6. Comparison of Post-Processing Techniques for the Detection of Perfusion Defects by Cardiac Computed Tomography in Patients Presenting with Acute ST Segment Elevation Myocardial Infarction

    PubMed Central

    Rogers, Ian S.; Cury, Ricardo C.; Blankstein, Ron; Shapiro, Michael D.; Nieman, Koen; Hoffmann, Udo; Brady, Thomas J.; Abbara, Suhny

    2010-01-01

    Background Despite rapid advances in cardiac computed tomography (CT), a strategy for optimal visualization of perfusion abnormalities on CT has yet to be validated. Objective To evaluate the performance of several post-processing techniques of source data sets to detect and characterize perfusion defects in acute myocardial infarctions with cardiac CT. Methods Twenty-one subjects (18 men; 60 ± 13 years) that were successfully treated with percutaneous coronary intervention for ST-segment myocardial infarction underwent 64-slice cardiac CT and 1.5 Tesla cardiac MRI scans following revascularization. Delayed enhancement MRI images were analyzed to identify the location of infarcted myocardium. Contiguous short axis images of the left ventricular myocardium were created from the CT source images using 0.75mm multiplanar reconstruction (MPR), 5mm MPR, 5mm maximal intensity projection (MIP), and 5mm minimum intensity projection (MinIP) techniques. Segments already confirmed to contain infarction by MRI were then evaluated qualitatively and quantitatively with CT. Results Overall, 143 myocardial segments were analyzed. On qualitative analysis, the MinIP and thick MPR techniques had greater visibility and definition than the thin MPR and MIP techniques (p < 0.001). On quantitative analysis, the absolute difference in Hounsfield Unit (HU) attenuation between normal and infarcted segments was significantly greater for the MinIP (65.4 HU) and thin MPR (61.2 HU) techniques. However, the relative difference in HU attenuation was significantly greatest for the MinIP technique alone (95%, p < 0.001). Contrast to noise was greatest for the MinIP (4.2) and thick MPR (4.1) techniques (p < 0.001). Conclusion The results of our current investigation found that MinIP and thick MPR detected infarcted myocardium with greater visibility and definition than MIP and thin MPR. PMID:20579617

  7. Myocardial Blood Flow and Inflammatory Cardiac Sarcoidosis.

    PubMed

    Kruse, Matthew J; Kovell, Lara; Kasper, Edward K; Pomper, Martin G; Moller, David R; Solnes, Lilja; Chen, Edward S; Schindler, Thomas H

    2017-02-01

    This study sought to evaluate the effects of inflammatory sarcoid disease on coronary circulatory function and the response to immune-suppressive treatment. Although positron emission tomography assessment of myocardial inflammation is increasingly applied to identify active cardiac sarcoidosis, its effect on coronary flow and immune-suppressive treatment remains to be characterized. Thirty-two individuals, who were referred for positron emission tomography/computed tomography, were evaluated for known or suspected cardiac sarcoidosis applying 18 F-fluorodeoxyglucose to determine inflammation and 13 N-ammonia to assess for perfusion deficits following a high-fat/low-carbohydrate diet and fasting state >12 h to suppress myocardial glucose uptake. Inflammation was quantified with standardized uptake value and regional myocardial blood flow at rest and during regadenoson-stimulated hyperemia was determined in ml/g/min. Positron emission tomography studies were repeated in 18 cases with a median follow-up of 2.5 years (interquartile range [IQR]:1.3 to 3.4 years). Twenty-five exams had normal perfusion but evidence of regional inflammation (group 1), and 21 exams presented a regional perfusion deficit associated with inflammation (group 2). Median myocardial blood flow did not differ between inflamed and noninflamed myocardium in both groups (0.86 ml/g/min [IQR: 0.66 to 1.11 ml/g/min] vs. 0.83 ml/g/min [IQR: 0.64 to 1.12 ml/g/min] and 0.74 ml/g/min [IQR: 0.60 to 0.93 ml/g/min] vs. 0.77 ml/g/min [IQR: 0.59 to 0.95 ml/g/min], respectively). As regards median hyperemic myocardial blood flows, they were significantly lower in the inflamed than in the remote regions in group 1 and 2 (2.31 ml/g/min [IQR: 1.81 to 2.95 ml/g/min] vs. 2.70 ml/g/min [IQR: 2.07 to 3.30 ml/g/min] and 1.61 ml/g/min [IQR: 1.17 to 2.18 ml/g/min] vs. 1.94 ml/g/min [IQR: 1.49 to 2.39 ml/g/min]; p < 0.001, respectively). Immune-suppression-mediated decrease in inflammation was associated with

  8. 48 CFR 30.201-1 - CAS applicability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false CAS applicability. 30.201-1 Section 30.201-1 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL CONTRACTING REQUIREMENTS COST ACCOUNTING STANDARDS ADMINISTRATION CAS Program Requirements 30.201-1 CAS...

  9. 48 CFR 1.201-2 - FAR Secretariat.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false FAR Secretariat. 1.201-2 Section 1.201-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 1.201-2 FAR Secretariat. (a) The General Services Administration...

  10. Deep Learning for Prediction of Obstructive Disease From Fast Myocardial Perfusion SPECT: A Multicenter Study.

    PubMed

    Betancur, Julian; Commandeur, Frederic; Motlagh, Mahsaw; Sharir, Tali; Einstein, Andrew J; Bokhari, Sabahat; Fish, Mathews B; Ruddy, Terrence D; Kaufmann, Philipp; Sinusas, Albert J; Miller, Edward J; Bateman, Timothy M; Dorbala, Sharmila; Di Carli, Marcelo; Germano, Guido; Otaki, Yuka; Tamarappoo, Balaji K; Dey, Damini; Berman, Daniel S; Slomka, Piotr J

    2018-03-12

    The study evaluated the automatic prediction of obstructive disease from myocardial perfusion imaging (MPI) by deep learning as compared with total perfusion deficit (TPD). Deep convolutional neural networks trained with a large multicenter population may provide improved prediction of per-patient and per-vessel coronary artery disease from single-photon emission computed tomography MPI. A total of 1,638 patients (67% men) without known coronary artery disease, undergoing stress 99m Tc-sestamibi or tetrofosmin MPI with new generation solid-state scanners in 9 different sites, with invasive coronary angiography performed within 6 months of MPI, were studied. Obstructive disease was defined as ≥70% narrowing of coronary arteries (≥50% for left main artery). Left ventricular myocardium was segmented using clinical nuclear cardiology software and verified by an expert reader. Stress TPD was computed using sex- and camera-specific normal limits. Deep learning was trained using raw and quantitative polar maps and evaluated for prediction of obstructive stenosis in a stratified 10-fold cross-validation procedure. A total of 1,018 (62%) patients and 1,797 of 4,914 (37%) arteries had obstructive disease. Area under the receiver-operating characteristic curve for disease prediction by deep learning was higher than for TPD (per patient: 0.80 vs. 0.78; per vessel: 0.76 vs. 0.73: p < 0.01). With deep learning threshold set to the same specificity as TPD, per-patient sensitivity improved from 79.8% (TPD) to 82.3% (deep learning) (p < 0.05), and per-vessel sensitivity improved from 64.4% (TPD) to 69.8% (deep learning) (p < 0.01). Deep learning has the potential to improve automatic interpretation of MPI as compared with current clinical methods. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Hyperintense Vessels on T2-PROPELLER-FLAIR in Patients with Acute MCA Stroke: Prediction of Arterial Stenosis and Perfusion Abnormality.

    PubMed

    Ahn, S J; Suh, S H; Lee, K-Y; Kim, J H; Seo, K-D; Lee, S

    2015-11-01

    Fluid-attenuated inversion recovery hyperintense vessels in stroke represent leptomeningeal collateral flow. We presumed that FLAIR hyperintense vessels would be more closely associated with arterial stenosis and perfusion abnormality in ischemic stroke on T2-PROPELLER-FLAIR than on T2-FLAIR. We retrospectively reviewed 35 patients with middle cerebral territorial infarction who underwent MR imaging. FLAIR hyperintense vessel scores were graded according to the number of segments with FLAIR hyperintense vessels in the MCA ASPECTS areas. We compared the predictability of FLAIR hyperintense vessels between T2-PROPELLER-FLAIR and T2-FLAIR for large-artery stenosis. The interagreement between perfusion abnormality and FLAIR hyperintense vessels was assessed. In subgroup analysis (9 patients with MCA horizontal segment occlusion), the association of FLAIR hyperintense vessels with ischemic lesion volume and perfusion abnormality volume was evaluated. FLAIR hyperintense vessel scores were significantly higher on T2-PROPELLER-FLAIR than on T2-FLAIR (3.50 ± 2.79 versus 1.21 ± 1.47, P < .01), and the sensitivity for large-artery stenosis was significantly improved on T2-PROPELLER-FLAIR (93% versus 68%, P = .03). FLAIR hyperintense vessels on T2-PROPELLER-FLAIR were more closely associated with perfusion abnormalities than they were on T2-FLAIR (κ = 0.64 and κ = 0.27, respectively). In subgroup analysis, FLAIR hyperintense vessels were positively correlated with ischemic lesion volume on T2-FLAIR, while the mismatch of FLAIR hyperintense vessels between the 2 sequences was negatively correlated with ischemic lesion volume (P = .01). In MCA stroke, FLAIR hyperintense vessels were more prominent on T2-PROPELLER-FLAIR compared with T2-FLAIR. In addition, FLAIR hyperintense vessels on T2-PROPELLER-FLAIR have a significantly higher sensitivity for predicting large-artery stenosis than they do on T2-FLAIR. Moreover, the areas showing FLAIR hyperintense vessels on T2-PROPELLER

  12. Myocardial Creatine Levels Do Not Influence Response to Acute Oxidative Stress in Isolated Perfused Heart

    PubMed Central

    Aksentijević, Dunja; Zervou, Sevasti; Faller, Kiterie M. E.; McAndrew, Debra J.; Schneider, Jurgen E.; Neubauer, Stefan; Lygate, Craig A.

    2014-01-01

    Background Multiple studies suggest creatine mediates anti-oxidant activity in addition to its established role in cellular energy metabolism. The functional significance for the heart has yet to be established, but antioxidant activity could contribute to the cardioprotective effect of creatine in ischaemia/reperfusion injury. Objectives To determine whether intracellular creatine levels influence responses to acute reactive oxygen species (ROS) exposure in the intact beating heart. We hypothesised that mice with elevated creatine due to over-expression of the creatine transporter (CrT-OE) would be relatively protected, while mice with creatine-deficiency (GAMT KO) would fare worse. Methods and Results CrT-OE mice were pre-selected for creatine levels 20–100% above wild-type using in vivo 1H–MRS. Hearts were perfused in isovolumic Langendorff mode and cardiac function monitored throughout. After 20 min equilibration, hearts were perfused with either H2O2 0.5 µM (30 min), or the anti-neoplastic drug doxorubicin 15 µM (100 min). Protein carbonylation, creatine kinase isoenzyme activities and phospho-PKCδ expression were quantified in perfused hearts as markers of oxidative damage and apoptotic signalling. Wild-type hearts responded to ROS challenge with a profound decline in contractile function that was ameliorated by co-administration of catalase or dexrazoxane as positive controls. In contrast, the functional deterioration in CrT-OE and GAMT KO hearts was indistinguishable from wild-type controls, as was the extent of oxidative damage and apoptosis. Exogenous creatine supplementation also failed to protect hearts from doxorubicin-induced dysfunction. Conclusions Intracellular creatine levels do not influence the response to acute ROS challenge in the intact beating heart, arguing against creatine exerting (patho-)physiologically relevant anti-oxidant activity. PMID:25272153

  13. Dynamic CT perfusion imaging of the myocardium: a technical note on improvement of image quality.

    PubMed

    Muenzel, Daniela; Kabus, Sven; Gramer, Bettina; Leber, Vivian; Vembar, Mani; Schmitt, Holger; Wildgruber, Moritz; Fingerle, Alexander A; Rummeny, Ernst J; Huber, Armin; Noël, Peter B

    2013-01-01

    To improve image and diagnostic quality in dynamic CT myocardial perfusion imaging (MPI) by using motion compensation and a spatio-temporal filter. Dynamic CT MPI was performed using a 256-slice multidetector computed tomography scanner (MDCT). Data from two different patients-with and without myocardial perfusion defects-were evaluated to illustrate potential improvements for MPI (institutional review board approved). Three datasets for each patient were generated: (i) original data (ii) motion compensated data and (iii) motion compensated data with spatio-temporal filtering performed. In addition to the visual assessment of the tomographic slices, noise and contrast-to-noise-ratio (CNR) were measured for all data. Perfusion analysis was performed using time-density curves with regions-of-interest (ROI) placed in normal and hypoperfused myocardium. Precision in definition of normal and hypoperfused areas was determined in corresponding coloured perfusion maps. The use of motion compensation followed by spatio-temporal filtering resulted in better alignment of the cardiac volumes over time leading to a more consistent perfusion quantification and improved detection of the extend of perfusion defects. Additionally image noise was reduced by 78.5%, with CNR improvements by a factor of 4.7. The average effective radiation dose estimate was 7.1±1.1 mSv. The use of motion compensation and spatio-temporal smoothing will result in improved quantification of dynamic CT MPI using a latest generation CT scanner.

  14. Scaling of myocardial mass to flow and morphometry of coronary arteries.

    PubMed

    Choy, Jenny Susana; Kassab, Ghassan S

    2008-05-01

    There is no doubt that scaling relations exist between myocardial mass and morphometry of coronary vasculature. The purpose of this study is to quantify several morphological (diameter, length, and volume) and functional (flow) parameters of the coronary arterial tree in relation to myocardial mass. Eight normal porcine hearts of 117-244 g (mean of 177.5 +/- 32.7) were used in this study. Various coronary subtrees of the left anterior descending, right coronary, and left circumflex arteries were perfused at pressure of 100 mmHg with different colors of a polymer (Microfil) to obtain rubber casts of arterial trees corresponding to different regions of myocardial mass. Volume, diameter, and cumulative length of coronary arteries were reconstructed from casts to analyze their relationship to the perfused myocardial mass. Volumetric flow was measured in relationship with perfused myocardial mass. Our results show that arterial volume is linearly related to regional myocardial mass, whereas the sum of coronary arterial branch lengths, vessel diameters, and volumetric flow show an approximately 3/4, 3/8, and 3/4 power-law relationship, respectively, in relation to myocardial mass. These scaling laws suggest fundamental design principles underlying the structure-function relationship of the coronary arterial tree that may facilitate diagnosis and management of diffuse coronary artery disease.

  15. Automated myocardial perfusion from coronary x-ray angiography

    NASA Astrophysics Data System (ADS)

    Storm, Corstiaan J.; Slump, Cornelis H.

    2010-03-01

    The purpose of our study is the evaluation of an algorithm to determine the physiological relevance of a coronary lesion as seen in a coronary angiogram. The aim is to extract as much as possible information from a standard coronary angiogram to decide if an abnormality, percentage of stenosis, as seen in the angiogram, results in physiological impairment of the blood supply of the region nourished by the coronary artery. Coronary angiography, still the golden standard, is used to determine the cause of angina pectoris based on the demonstration of an important stenose in a coronary artery. Dimensions of a lesion such as length and percentage of narrowing can at present easily be calculated by using an automatic computer algorithm such as Quantitative Coronary Angiography (QCA) techniques resulting in just anatomical information ignoring the physiological relevance of the lesion. In our study we analyze myocardial perfusion images in standard coronary angiograms in rest and in artificial hyperemic phases, using a drug e.g. papaverine intracoronary. Setting a Region of Interest (ROI) in the angiogram without overlying major vessels makes it possible to calculate contrast differences as a function of time, so called time-density curves, in the basal and hyperemic phases. In minimizing motion artifacts, end diastolic images are selected ECG based in basal and hyperemic phase in an identical ROI in the same angiographic projection. The development of new algorithms for calculating differences in blood supply in the region as set are presented together with the results of a small clinical case study using the standard angiographic procedure.

  16. T-Wave Abnormality as Electrocardiographic Signature of Myocardial Edema in Non-ST-Elevation Acute Coronary Syndromes.

    PubMed

    Cardona, Andrea; Zareba, Karolina M; Nagaraja, Haikady N; Schaal, Stephen F; Simonetti, Orlando P; Ambrosio, Giuseppe; Raman, Subha V

    2018-01-26

    T-wave abnormalities are common during the acute phase of non-ST-segment elevation acute coronary syndromes, but mechanisms underlying their occurrence are unclear. We hypothesized that T-wave abnormalities in the presentation of non-ST-segment elevation acute coronary syndromes correspond to the presence of myocardial edema. Secondary analysis of a previously enrolled prospective cohort of patients presenting with non-ST-segment elevation acute coronary syndromes was conducted. Twelve-lead electrocardiography (ECG) and cardiac magnetic resonance with T2-weighted imaging were acquired before invasive coronary angiography. ECGs were classified dichotomously (ie, ischemic versus normal/nonischemic) and nominally according to patterns of presentation: no ST- or T-wave abnormalities, isolated T-wave abnormality, isolated ST depression, ST depression+T-wave abnormality. Myocardial edema was determined by expert review of T2-weighted images. Of 86 subjects (65% male, 59.4 years), 36 showed normal/nonischemic ECG, 25 isolated T-wave abnormalities, 11 isolated ST depression, and 14 ST depression+T-wave abnormality. Of 30 edema-negative subjects, 24 (80%) had normal/nonischemic ECGs. Isolated T-wave abnormality was significantly more prevalent in edema-positive versus edema-negative subjects (41.1% versus 6.7%, P =0.001). By multivariate analysis, an ischemic ECG showed a strong association with myocardial edema (odds ratio 12.23, 95% confidence interval 3.65-40.94, P <0.0001). Among individual ECG profiles, isolated T-wave abnormality was the single strongest predictor of myocardial edema (odds ratio 23.84, 95% confidence interval 4.30-132, P <0.0001). Isolated T-wave abnormality was highly specific (93%) but insensitive (43%) for detecting myocardial edema. T-wave abnormalities in the setting of non-ST-segment elevation acute coronary syndromes are related to the presence of myocardial edema. High specificity of this ECG alteration identifies a change in ischemic

  17. Sensitivity of mechanical and metabolic functions to changes in coronary perfusion: A metabolic basis of perfusion-contraction coupling.

    PubMed

    Askenasy, N

    2000-05-01

    Experimental evidence indicates a metabolic basis of contraction-perfusion coupling during an increase in cardiac work load. This study aims to characterize adjustment of myocardial energy metabolism in response to acute low flow ischemia (LFI), and to determine its involvement in perfusion-contraction coupling. Intracellular parameters were measured in isolated rat hearts by NMR spectroscopy and biochemical methods during 30 min of graded LFI and reperfusion as compared to continuous perfusion (control). Oxygen pressure was set to reach maximal oxygen extraction at 70% coronary flow rate (CFR), therefore oxygen limitation was proportional to coronary underperfusion. At 69, 38 and 10% CFR left ventricular pressures decreased to 71, 43 and 25% of pre-ischemic values respectively (P<0.005 v 97% in control) without an increase in diastolic tone, and recovered to 92+/-3% after 30 min of reperfusion. Despite hydrolysis of high energy phosphates and cellular acidification, ADP concentrations were stable in underperfused hearts. At 69, 38 and 10% CFR, cytosolic phosphorylation potentials (PP) decreased from 74+/-10 m M(-1)during pre-ischemia to 40+/-6, 25+/-4 and 14+/-4 m M(-1)respectively (P<0.05 v 63+/-9 m M(-1)in control), and lactate efflux increased to 256+/-18, 386+/-22 and 490+/-43 micromol /gdw respectively (P<0.005 v 186+/-22 micromol/gdw in control). Glycogen contents decreased (P<0.005 v control) and accounted for 27-30% of lactate efflux. These results indicate: (a) proportionate depression of contraction force and glycogen contents, and increased glucose uptake and anaerobic energy production in the underperfused myocardium. Coordinated modulation of these parameters attributes cytosolic PP a regulatory function; (b) resetting of cytosolic PP to lower levels mediates perfusion-contraction coupling during graded LFI. The data are consistent with the concept that glycolytic energy production improves myocardial tolerance to ischemia. Copyright 2000 Academic

  18. Experience of low-dose aminophylline use to relieve minor adverse effects of dipyridamole in patients undergoing stress myocardial perfusion imaging.

    PubMed

    Lin, Li-Fan; Cheng, Cheng-Yi; Hou, Cheng-Han; Ku, Chih-Hung; Tseng, Neng-Chuan; Shen, Daniel H Y

    2014-06-01

    Intravenous administration of aminophylline is widely adopted to reverse dipyridamole-related adverse effects (AEs) during stress myocardial perfusion imaging (MPI). The study aimed to investigate the efficacy of lower-dose aminophylline to relieve minor AEs. 2,250 consecutive patients undergoing dipyridamole-stressed MPI were enrolled. Information concerning AE occurrence and dosages of aminophylline was collected to evaluate the efficacy of lower-dose aminophylline. A logistic regression was used to determine independent predictors of dipyridamole-related AE occurrence. No severe AE was noted. Overall mild AE incidence was 37.0% (833/2,250 patients). Initial low-dose (25 mg) aminophylline relieved symptoms in 98.8% of patients with mild AEs (823/833 patients). An extra 25 mg aminophylline sufficed to reverse all such AEs. Mean body mass index (BMI) differed significantly between patients with and without any AE [25.6 vs 25.1 (P = .009)]. There was no significant difference between two subgroups in mean age, male gender prevalence, body height and weight, dipyridamole dose/BMI, or prevalence of significant perfusion defect(s) on MPI. Multivariable logistic regression demonstrated BMI remained the independent predictor of dipyridamole-related AE occurrence (odds ratio 1.028, 95% confidence interval 1.007-1.049, P = .01). Low-dose (≦50 mg, and usually 25 mg) aminophylline seems sufficient to relieve mild dipyridamole-related AEs during stress MPI.

  19. The DD genotype of the angiotensin converting enzyme gene independently associates with CMR-derived abnormal microvascular perfusion in patients with a first anterior ST-segment elevation myocardial infarction treated with thrombolytic agents.

    PubMed

    Bodi, Vicente; Sanchis, Juan; Nunez, Julio; Aliño, Salvador F; Herrero, Maria J; Chorro, Francisco J; Mainar, Luis; Lopez-Lereu, Maria P; Monmeneu, Jose V; Oltra, Ricardo; Chaustre, Fabian; Forteza, Maria J; Husser, Oliver; Riegger, Günter A; Llacer, Angel

    2009-12-01

    The role of the angiotensin converting enzyme (ACE) gene on the result of thrombolysis at the microvascular level has not been addressed so far. We analyzed the implications of the insertion/deletion (I/D) polymorphism of the ACE gene on the presence of abnormal cardiovascular magnetic resonance (CMR)-derived microvascular perfusion after ST-segment elevation myocardial infarction (STEMI). We studied 105 patients with a first anterior STEMI treated with thrombolytic agents and an open left anterior descending artery. Microvascular perfusion was assessed using first-pass perfusion CMR at 7+/-1 days. CMR studies were repeated 184+/-11 days after STEMI. The ACE gene insertion/deletion (I/D) polymorphism was determined using polymerase chain reaction amplification. Overall genotype frequencies were II-ID 58% and DD 42%. Abnormal perfusion (> or = 1 segment) was detected in 56% of patients. The DD genotype associated to a higher risk of abnormal microvascular perfusion (68% vs. 47%, p=0.03) and to a larger extent of perfusion deficit (median [percentile 25 - percentile 75]: 4 [0-6] vs. 0 [0-4] segments, p=0.003). Once adjusted for baseline characteristics, the DD genotype independently increased the risk of abnormal microvascular perfusion (odds ratio [95% confidence intervals]: 2.5 [1.02-5.9], p=0.04). Moreover, DD patients displayed a larger infarct size (35+/-17 vs. 27+/-15 g, p=0.01) and a lower ejection fraction at 6 months (48+/-14 vs. 54+/-14%, p=0.03). The DD genotype associates to a higher risk of abnormal microvascular perfusion after STEMI.

  20. 7 CFR 201.1 - Meaning of words.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Meaning of words. 201.1 Section 201.1 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS Definitions § 201.1 Meaning of words. Words in the regulations in this part in the singular form...

  1. 19 CFR 201.1 - Applicability of part.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Applicability of part. 201.1 Section 201.1 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION GENERAL RULES OF GENERAL APPLICATION § 201.1 Applicability of part. This part relates generally to functions and activities of the Commission under various...

  2. 19 CFR 201.1 - Applicability of part.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 3 2012-04-01 2012-04-01 false Applicability of part. 201.1 Section 201.1 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION GENERAL RULES OF GENERAL APPLICATION § 201.1 Applicability of part. This part relates generally to functions and activities of the Commission under various...

  3. 19 CFR 201.1 - Applicability of part.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 3 2013-04-01 2013-04-01 false Applicability of part. 201.1 Section 201.1 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION GENERAL RULES OF GENERAL APPLICATION § 201.1 Applicability of part. This part relates generally to functions and activities of the Commission under various...

  4. 19 CFR 201.1 - Applicability of part.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 3 2011-04-01 2011-04-01 false Applicability of part. 201.1 Section 201.1 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION GENERAL RULES OF GENERAL APPLICATION § 201.1 Applicability of part. This part relates generally to functions and activities of the Commission under various...

  5. 19 CFR 201.1 - Applicability of part.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 3 2014-04-01 2014-04-01 false Applicability of part. 201.1 Section 201.1 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION GENERAL RULES OF GENERAL APPLICATION § 201.1 Applicability of part. This part relates generally to functions and activities of the Commission under various...

  6. A template-based approach to semi-quantitative SPECT myocardial perfusion imaging: Independent of normal databases.

    PubMed

    Hughes, Tyler; Shcherbinin, Sergey; Celler, Anna

    2011-07-01

    Normal patient databases (NPDs) are used to distinguish between normal and abnormal perfusion in SPECT myocardial perfusion imaging (MPI) and have gained wide acceptance in the clinical environment, yet there are limitations to this approach. This study introduces a template-based method for semi-quantitative MPI, which attempts to overcome some of the NPD limitations. Our approach involves the construction of a 3D digital healthy heart template from the delineation of the patient's left ventricle in the SPECT image. This patient-specific template of the heart, filled with uniform activity, is then analytically projected and reconstructed using the same algorithm as the original image. Subsequent to generating bulls-eye maps for the patient image (PB) and the template image (TB), a ratio (PB/TB) is calculated, which produces a reconstruction-artifact corrected image (CB). Finally, a threshold is used to define defects within CB enabling measurements of the perfusion defect extent (EXT). The SPECT-based template (Ts) measurements were compared to those of a CT-based "ideal" template (TI). Twenty digital phantoms were simulated: male and female, each with one healthy heart and nine hearts with various defects. Four physical phantom studies were performed modeling a healthy heart and three hearts with different defects. The phantom represented a thorax with spine, lung, and left ventricle inserts. Images were acquired on General Electric's (GE) Infinia Hawkeye SPECT/CT camera using standard clinical MPI protocol. Finally, our method was applied to 14 patient MPI rest/stress studies acquired on the GE Infinia Hawkeye SPECT/CT camera and compared to the results obtained from Cedars-Sinai's QPS software. In the simulation studies, the true EXT correlated well with the TI (slope= 1.08; offset = -0.40%; r = 0.99) and Ts (slope = 0.90; offset = 0.27%; r = 0.99) methods with no significant differences between them. Similarly, strong correlations were measured for EXT

  7. Revision of gonadal radiation dose to man from thallium-201

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosain, P.; Hosain, F.

    1981-06-01

    Thallium-201 as thallous chloride is now routinely used for myocardial imaging. We observed a biological translocation of T1-201 leading to a gradual increase in the concentration of radioactivity in the testes which facilitated testicular imaging. The initial distribution of intravenously injected tracer dose is greatly dependent on the distribution of cardiac output, but its metabolic fate is analogous to the potassium ion. We have extensively studied the kinetics of thallium in rats, and also carried out limited comparative studies in different species. An attempt was also made to compare the uptake values that could be obtained in dogs by quantitativemore » imaging and by autopsy. Separation of scrotum, epididymis and testes revealed that the increase in uptake occurred predominantly in the testes. The uptake increased with time for about 1 day, and after 2 days it declined with a biological half-life of approximately 2 days. The later phase of testicular clearance was similar to the rate of clearance from other organs. The testicular uptake of T1-201 was highest in rats: the initial value at 10 to 15 min was 0.48 +- 0.09% of the injected dose which increased to 1.77 +- 0.20% by 1 day. The initial uptake in mice was low (0.18 +- 0.06%) but it increased to about 4 folds by 1 day. Values in human, extrapolated from limited quantitative imaging, was similar to mice. These studies indicated the need for the revision of the gonadal radiation dose to man. Calculations show, contrary to the accepted value of about 0.5 rads/mCi, an approximate value of 1.5 rads/mCi is more realistic.« less

  8. Left ventricular functional parameters by gated SPECT myocardial perfusion imaging in a Latin American country.

    PubMed

    Kapitan, Miguel; Beltran, Alvaro; Beretta, Mario; Mut, Fernando

    2018-04-01

    There is paucity of data on left ventricular (LV) functional parameters using gated SPECT myocardial perfusion imaging (MPI) from the Latin American region. This study provides detailed information in low-risk patients both at rest and during exercise. We studied 90 patients (50 men) with a very low likelihood of coronary artery disease. Gated-SPECT MPI was performed with Tc-99m MIBI using a 2-day protocol, with 16 frames/R-R cycle. The LV ejection fraction and volumes were not different between the rest and post-stress images. LVEF was 68 ± 7% post-stress and 70 ± 7% at rest in women, and 62 ± 7% and 63 ± 7%, respectively, in men (P = .19, .26). LV volumes were larger in men than women (P < .01). There were no differences in most variables obtained at rest or post-stress. Transient ischemic dilatation was similar, with upper limits of 1.20 and 1.19 in women and men, respectively (P = NS). These data could prove helpful for the interpretation of gated SPECT MPI data in Latin America using identical protocol as used in this study.

  9. Accelerated dual-contrast first-pass perfusion MRI of the mouse heart: development and application to diet-induced obese mice.

    PubMed

    Naresh, Nivedita K; Chen, Xiao; Roy, Rene J; Antkowiak, Patrick F; Annex, Brian H; Epstein, Frederick H

    2015-03-01

    Gene-modified mice may be used to elucidate molecular mechanisms underlying abnormal myocardial blow flow (MBF). We sought to develop a quantitative myocardial perfusion imaging technique for mice and to test the hypothesis that myocardial perfusion reserve (MPR) is reduced in a mouse model of diet-induced obesity (DIO). A dual-contrast saturation-recovery sequence with ky -t undersampling and a motion-compensated compressed sensing reconstruction algorithm was developed for first-pass MRI on a small-bore 7 Tesla system. Control mice were imaged at rest and with the vasodilators ATL313 and Regadenoson (n = 6 each). In addition, we imaged mice fed a high-fat diet (HFD) for 24 weeks. In control mice, MBF was 5.7 ± 0.8 mL/g/min at rest and it increased to 11.8 ± 0.6 mL/g/min with ATL313 and to 10.4 ± 0.3 mL/g/min with Regadenoson. In HFD mice, we detected normal resting MBF (5.6 ± 0.4 versus 5.0 ± 0.3 on control diet), low MBF at stress (7.7 ± 0.4 versus 10.4 ± 0.3 on control diet, P < 0.05), and reduced MPR (1.4 ± 0.2 versus 2.0 ± 0.3 on control diet, P < 0.05). Accelerated dual-contrast first-pass MRI with motion-compensated compressed sensing provides spatiotemporal resolution suitable for measuring MBF in free-breathing mice, and detected reduced MPR in DIO mice. These techniques may be used to study molecular mechanisms that underlie abnormal myocardial perfusion. © 2014 Wiley Periodicals, Inc.

  10. Highly automatic quantification of myocardial oedema in patients with acute myocardial infarction using bright blood T2-weighted CMR

    PubMed Central

    2013-01-01

    Background T2-weighted cardiovascular magnetic resonance (CMR) is clinically-useful for imaging the ischemic area-at-risk and amount of salvageable myocardium in patients with acute myocardial infarction (MI). However, to date, quantification of oedema is user-defined and potentially subjective. Methods We describe a highly automatic framework for quantifying myocardial oedema from bright blood T2-weighted CMR in patients with acute MI. Our approach retains user input (i.e. clinical judgment) to confirm the presence of oedema on an image which is then subjected to an automatic analysis. The new method was tested on 25 consecutive acute MI patients who had a CMR within 48 hours of hospital admission. Left ventricular wall boundaries were delineated automatically by variational level set methods followed by automatic detection of myocardial oedema by fitting a Rayleigh-Gaussian mixture statistical model. These data were compared with results from manual segmentation of the left ventricular wall and oedema, the current standard approach. Results The mean perpendicular distances between automatically detected left ventricular boundaries and corresponding manual delineated boundaries were in the range of 1-2 mm. Dice similarity coefficients for agreement (0=no agreement, 1=perfect agreement) between manual delineation and automatic segmentation of the left ventricular wall boundaries and oedema regions were 0.86 and 0.74, respectively. Conclusion Compared to standard manual approaches, the new highly automatic method for estimating myocardial oedema is accurate and straightforward. It has potential as a generic software tool for physicians to use in clinical practice. PMID:23548176

  11. Use of atropine in patients with submaximal heart rate during exercise myocardial perfusion SPECT.

    PubMed

    De Lorenzo, Andrea; Foerster, James; Sciammarella, Maria G; Suey, Cathy; Hayes, Sean W; Friedman, John D; Berman, Daniel S

    2003-01-01

    Failure to reach 85% of maximal predicted heart rate (MPHR) during exercise may render a myocardial perfusion single photon emission computed tomography (MPS) study nondiagnostic for ischemia detection. Although commonly used to increase heart rate (HR) during dobutamine stress, the administration of atropine for patients failing to achieve 85% of MPHR during exercise performed for MPS is still infrequent. Patients undergoing dual-isotope MPS were considered candidates for the study when, during exercise treadmill testing, they had less than 85% of MPHR and were unable to continue because of fatigue, without an ischemic response. Forty-seven patients (aged 65.3 +/- 12.5 years, 78.7% men) received atropine (0.6-1.2 mg). Maximal HR achieved before and after atropine was 118.0 +/- 14.8 beats/min (76.3% +/- 6.2% of MPHR) and 146.4 +/- 12.6 beats/min (94.4% +/- 8.1% of MPHR), respectively (P < .001). Of patients, 44 (93.6%) reached at least 85% of MPHR after atropine and had diagnostic MPS studies. After atropine, arrhythmias occurred in 14 patients (29.8%) and other minor side effects in 1 (2.1%). Atropine allows patients initially failing to achieve 85% of MPHR during exercise to increase HR and have a diagnostic MPS study, without major complications. It may provide an alternative to pharmacologic stress for patients with a blunted HR response to exercise.

  12. An investigation of the trade-off between the count level and image quality in myocardial perfusion SPECT using simulated images: the effects of statistical noise and object variability on defect detectability

    NASA Astrophysics Data System (ADS)

    He, Xin; Links, Jonathan M.; Frey, Eric C.

    2010-09-01

    Quantum noise as well as anatomic and uptake variability in patient populations limits observer performance on a defect detection task in myocardial perfusion SPECT (MPS). The goal of this study was to investigate the relative importance of these two effects by varying acquisition time, which determines the count level, and assessing the change in performance on a myocardial perfusion (MP) defect detection task using both mathematical and human observers. We generated ten sets of projections of a simulated patient population with count levels ranging from 1/128 to around 15 times a typical clinical count level to simulate different levels of quantum noise. For the simulated population we modeled variations in patient, heart and defect size, heart orientation and shape, defect location, organ uptake ratio, etc. The projection data were reconstructed using the OS-EM algorithm with no compensation or with attenuation, detector response and scatter compensation (ADS). The images were then post-filtered and reoriented to generate short-axis slices. A channelized Hotelling observer (CHO) was applied to the short-axis images, and the area under the receiver operating characteristics (ROC) curve (AUC) was computed. For each noise level and reconstruction method, we optimized the number of iterations and cutoff frequencies of the Butterworth filter to maximize the AUC. Using the images obtained with the optimal iteration and cutoff frequency and ADS compensation, we performed human observer studies for four count levels to validate the CHO results. Both CHO and human observer studies demonstrated that observer performance was dependent on the relative magnitude of the quantum noise and the patient variation. When the count level was high, the patient variation dominated, and the AUC increased very slowly with changes in the count level for the same level of anatomic variability. When the count level was low, however, quantum noise dominated, and changes in the count level

  13. Cardiac MOLLI T1 mapping at 3.0 T: comparison of patient-adaptive dual-source RF and conventional RF transmission.

    PubMed

    Rasper, Michael; Nadjiri, Jonathan; Sträter, Alexandra S; Settles, Marcus; Laugwitz, Karl-Ludwig; Rummeny, Ernst J; Huber, Armin M

    2017-06-01

    To prospectively compare image quality and myocardial T 1 relaxation times of modified Look-Locker inversion recovery (MOLLI) imaging at 3.0 T (T) acquired with patient-adaptive dual-source (DS) and conventional single-source (SS) radiofrequency (RF) transmission. Pre- and post-contrast MOLLI T 1 mapping using SS and DS was acquired in 27 patients. Patient wise and segment wise analysis of T 1 times was performed. The correlation of DS MOLLI measurements with a reference spin echo sequence was analysed in phantom experiments. DS MOLLI imaging reduced T 1 standard deviation in 14 out of 16 myocardial segments (87.5%). Significant reduction of T 1 variance could be obtained in 7 segments (43.8%). DS significantly reduced myocardial T 1 variance in 16 out of 25 patients (64.0%). With conventional RF transmission, dielectric shading artefacts occurred in six patients causing diagnostic uncertainty. No according artefacts were found on DS images. DS image findings were in accordance with conventional T 1 mapping and late gadolinium enhancement (LGE) imaging. Phantom experiments demonstrated good correlation of myocardial T 1 time between DS MOLLI and spin echo imaging. Dual-source RF transmission enhances myocardial T 1 homogeneity in MOLLI imaging at 3.0 T. The reduction of signal inhomogeneities and artefacts due to dielectric shading is likely to enhance diagnostic confidence.

  14. Washout of ⁸²Rb as a marker of impaired tissue integrity, obtained by list-mode cardiac PET/CT: relationship with perfusion/metabolism patterns of myocardial viability.

    PubMed

    Chien, David T; Bravo, Paco; Higuchi, Takahiro; Merrill, Jennifer; Bengel, Frank M

    2011-08-01

    Myocardial washout of the potassium analogue (82)Rb may indicate tissue impairment. Few studies have evaluated its usefulness for viability assessment, and controversial results were reported. We revisited this topic using list-mode positron emission tomography (PET)/CT. A total of 22 patients with chronic ischemic cardiomyopathy (ICM) and 11 control subjects with normal CT coronary angiogram were studied. Rest (82)Rb PET/CT studies were acquired in list mode and resampled to static, gated, and dynamic images. Using a 17-segment model, (82)Rb washout was determined by monoexponential fitting of myocardial time-activity curves. In ICM patients, (18)F-fluorodeoxyglucose (FDG) studies were obtained in the same session and segments were classified as normally perfused, mismatch, or matched defect. (82)Rb washout was minimal and homogeneous in control subjects. Normally perfused segments of ICM did not differ (p = 0.33). ICM patients had a left ventricular ejection fraction (LVEF) of 25 ± 12%, 25/353 mismatched, and 46/353 matched defect segments. (82)Rb washout was higher in hypoperfused vs normal segments (p < 0.05), but not different between mismatch and matched defect (p = 0.18). Intraindividual analysis in nine patients showing both FDG mismatch and matched defect confirmed absence of differences. Overall, segmental (82)Rb washout correlated inversely with (82)Rb uptake (r = -0.70; p < 0.05) and less well with FDG uptake (r = -0.31; p < 0.05). Using state-of-the-art PET/CT technology for myocardial viability assessment, (82)Rb washout does not distinguish between perfusion/metabolism patterns of hibernating myocardium and scar. Tissue integrity may be at least partially impaired in hibernation.

  15. Use of bio-informatics assessment schema (BIAS) to improve diagnosis and prognosis of myocardial perfusion data: results from the NHLBI-sponsored women's ischemia syndrome evaluation (WISE).

    PubMed

    Doyle, Mark; Pohost, Gerald M; Bairey Merz, C Noel; Shaw, Leslee J; Sopko, George; Rogers, William J; Sharaf, Barry L; Pepine, Carl J; Thompson, Diane V; Rayarao, Geetha; Tauxe, Lindsey; Kelsey, Sheryl F; Biederman, Robert W W

    2016-10-01

    We introduce an algorithmic approach to optimize diagnostic and prognostic value of gated cardiac single photon emission computed tomography (SPECT) and magnetic resonance (MR) myocardial perfusion imaging (MPI) modalities in women with suspected myocardial ischemia. The novel approach: bio-informatics assessment schema (BIAS) forms a mathematical model utilizing MPI data and cardiac metrics generated by one modality to predict the MPI status of another modality. The model identifies cardiac features that either enhance or mask the image-based evidence of ischemia. For each patient, the BIAS model value is used to set an appropriate threshold for the detection of ischemia. Women (n=130), with symptoms and signs of suspected myocardial ischemia, underwent MPI assessment for regional perfusion defects using two different modalities: gated SPECT and MR. To determine perfusion status, MR data were evaluated qualitatively (MRI QL ) and semi-quantitatively (MRI SQ ) while SPECT data were evaluated using conventional clinical criteria. Evaluators were masked to results of the alternate modality. These MPI status readings were designated "original". Two regression models designated "BIAS" models were generated to model MPI status obtained with one modality (e.g., MRI) compared with a second modality (e.g., SPECT), but importantly, the BIAS models did not include the primary Original MPI reading of the predicting modality. Instead, the BIAS models included auxiliary measurements like left ventricular chamber volumes and myocardial wall thickness. For each modality, the BIAS model was used to set a progressive threshold for interpretation of MPI status. Women were then followed for 38±14 months for the development of a first major adverse cardiovascular event [MACE: CV death, nonfatal myocardial infarction (MI) or hospitalization for heart failure]. Original and BIAS-augmented perfusion status were compared in their ability to detect coronary artery disease (CAD) and for

  16. Combined anatomical and functional imaging using coronary CT angiography and myocardial perfusion SPECT in symptomatic adults with abnormal origin of a coronary artery.

    PubMed

    Uebleis, C; Groebner, M; von Ziegler, F; Becker, A; Rischpler, C; Tegtmeyer, R; Becker, C; Lehner, S; Haug, A R; Cumming, P; Bartenstein, P; Franz, W M; Hacker, M

    2012-10-01

    There has been a lack of standardized workup guidelines for patients with congenital abnormal origin of a coronary artery from the opposite sinus (ACAOS). We aimed to evaluate the use of cardiac hybrid imaging using multi-detector row CT (MDCT) for coronary CT angiography (Coronary CTA) and stress-rest myocardial perfusion SPECT (MPS) for comprehensive diagnosis of symptomatic adult patients with ACAOS. Seventeen symptomatic patients (12 men; 54 ± 13 years) presenting with ACAOS underwent coronary CTA and MPS. Imaging data were analyzed by conventional means, and with additional use of 3D image fusion to allocate stress induced perfusion defects (PD) to their supplying coronary arteries. An anomalous RCA arose from the left anterior sinus in eight patients, an abnormal origin from the right sinus was detected in nine patients (5 left coronary arteries, LCA and 4 LCx). Five of the 17 patients (29%) demonstrated a reversible PD in MPS. There was no correlation between the anatomical variants of ACAOS and the presence of myocardial ischemia. Image fusion enabled the allocation of reversible PD to the anomalous vessel in three patients (two cases in the RCA and the other in the LCA territory); PD in two patients were allocated to the territory of artery giving rise to the anomalies, rather than the anomalies themselves. In a small cohort of adult symptomatic patients with ACAOS anomaly there was no relation found between the specific anatomical variant and the appearance of stress induced myocardial ischemia using cardiac hybrid imaging.

  17. Myocardial viability assessed with fluorodeoxyglucose and PET in patients with Q wave myocardial infarction receiving thrombolysis: relationship to coronary anatomy and ventricular function.

    PubMed

    Fragasso, G; Chierchia, S L; Rossetti, E; Sciammarella, M G; Conversano, A; Lucignani, G; Landoni, C; Calori, G; Margonato, A; Fazio, F

    1997-03-01

    In previously thrombolysed patients, we analysed residual myocardial viability using the PET-FDG technique and correlated its presence and extent to the angiographic appearance of the infarct-related vessel and left ventricular function. Thirty-six patients who had undergone intravenous thromboloysis for acute myocardial infarction 4.8 +/- 7.2 months previously were studied. Coronary angiography, left ventriculography, and assessment of myocardial perfusion and metabolism were all performed within 1 week. All patients exhibited perfusion defects consistent with the clinically identified myocardial infarction site. Residual viability, as assessed by the PET-FDG technique, was present in 53% of cases. The infarct-related coronary artery was patent in 19 (53%) patients (TIMI grade 3, 79%); of the remaining 17 with occluded infarct-related arteries, 11 had collaterals to the infarct area. Significant FDG uptake was observed in 63% of patients with a patent infarct-related artery and in 41% of those with an occluded infarct-related artery. The same study protocol was adopted in a control group of 30 patients with myocardial infarction who did not receive thrombolysis. The number of infarct-related patent vessels was significantly lower in these patients (30 vs 53%) (TIMI grade 3, 56%), but the overall percentage of PET viability was again 53%. Qualitative analysis of the regional perfusion pattern showed that the magnitude and severity of the perfusion defect was similar in the two groups, regardless of the presence or absence of FDG uptake. Global left ventricular function was also similar in the two groups. However, regional wall motion was significantly better in the thrombolysed patients with a patent infarct-related artery than in those who had not received thrombolysis and whose culprit vessel was also patent. In conclusion, the results of our study support the notion that early recanalization of the infarct-related artery is critical for preserving left

  18. Scaling of Myocardial Mass to Flow and Morphometry of Coronary Arteries

    PubMed Central

    Choy, Jenny Susana; Kassab, Ghassan S.

    2009-01-01

    There is no doubt that scaling relations exist between myocardial mass and morphometry of coronary vasculature. The purpose of this study is to quantify several morphological (diameter, length, and volume) and functional (flow) parameters of the coronary arterial tree in relation to myocardial mass. Eight normal porcine hearts of 117-244 g (mean of 177.5±32.7) were used in this study. Various coronary sub-trees of the Left Anterior Descending (LAD), Right Coronary (RCA) and Left Circumflex (LCX) arteries were perfused at pressure of 100 mmHg with different colors of a polymer (Microfil) in order to obtain rubber casts of arterial trees corresponding to different regions of myocardial mass. Volume, diameter and cumulative length of coronary arteries were reconstructed from casts to analyze their relationship to the perfused myocardial mass. Volumetric flow was measured in relationship with perfused myocardial mass. Our results show that arterial volume is linearly related to regional myocardial mass, whereas the sum of coronary arterial branch lengths, vessel diameters and volumetric flow show an approximately 3/4, 3/8 and 3/4 power-law relationship, respectively, in relation to myocardial mass. These scaling laws suggest fundamental design principles underlying the structure-function relationship of the coronary arterial tree that may facilitate diagnosis and management of diffuse coronary artery disease. PMID:18323461

  19. Applying the J-optimal channelized quadratic observer to SPECT myocardial perfusion defect detection

    NASA Astrophysics Data System (ADS)

    Kupinski, Meredith K.; Clarkson, Eric; Ghaly, Michael; Frey, Eric C.

    2016-03-01

    To evaluate performance on a perfusion defect detection task from 540 image pairs of myocardial perfusion SPECT image data we apply the J-optimal channelized quadratic observer (J-CQO). We compare AUC values of the linear Hotelling observer and J-CQO when the defect location is fixed and when it occurs in one of two locations. As expected, when the location is fixed a single channels maximizes AUC; location variability requires multiple channels to maximize the AUC. The AUC is estimated from both the projection data and reconstructed images. J-CQO is quadratic since it uses the first- and second- order statistics of the image data from both classes. The linear data reduction by the channels is described by an L x M channel matrix and in prior work we introduced an iterative gradient-based method for calculating the channel matrix. The dimensionality reduction from M measurements to L channels yields better estimates of these sample statistics from smaller sample sizes, and since the channelized covariance matrix is L x L instead of M x M, the matrix inverse is easier to compute. The novelty of our approach is the use of Jeffrey's divergence (J) as the figure of merit (FOM) for optimizing the channel matrix. We previously showed that the J-optimal channels are also the optimum channels for the AUC and the Bhattacharyya distance when the channel outputs are Gaussian distributed with equal means. This work evaluates the use of J as a surrogate FOM (SFOM) for AUC when these statistical conditions are not satisfied.

  20. Prognostic Value of Real Time Myocardial Contrast Echocardiography after Percutaneous Coronary Intervention.

    PubMed

    Yang, Lixia; Xia, Chunmei; Mu, Yuming; Guan, Lina; Wang, Chunmei; Tang, Qi; Verocai, Flavia Gomes; Fonseca, Lea Mirian Barbosa da; Shih, Ming Chi

    2016-03-01

    Real time myocardial contrast echocardiography (RTMCE) is a cost-effective and simple method to quantify coronary flow reserve (CFR). We aimed to determine the value of RTMCE to predict cardiac events after percutaneous coronary intervention (PCI). We have studied myocardial blood volume (A), velocity (β), flow indexes (MBF, A × β), and vasodilator reserve (stress-to-rest ratios) in 36 patients with acute coronary syndrome (ACS) who underwent PCI. CFR (MBF at stress/MBF at rest) was calculated for each patient. Perfusion scores were used for visual interpretation by MCE and correlation with TIMI flow grade. In qualitative RTMCE assessment, post-PCI visual perfusion scores were higher than pre-PCI (Z = -7.26, P < 0.01). Among 271 arteries with TIMI flow grade 3 post-PCI, 72 (36%) did not reach visual perfusion score 1. The β- and A × β-reserve of the abnormal segments supplied by obstructed arteries increased after PCI comparing to pre-PCI values (P < 0.01). Patients with adverse cardiac events had significantly lower β- and lower A × β-reserve than patients without adverse cardiac events. In the former group, the CFR was ≥ 1.5 both pre- and post-PCI. CFR estimation by RTMCE can quantify myocardial perfusion in patients with ACS who underwent PCI. The parameters β-reserve and CFR combined might predict cardiac events on the follow-up. © 2015, Wiley Periodicals, Inc.

  1. Myocardial perfusion in patients with suspected coronary artery disease: comparison between 320-MDCT and rubidium-82 PET.

    PubMed

    Dantas, Roberto Nery; Assuncao, Antonildes Nascimento; Marques, Ismar Aguiar; Fahel, Mateus Guimaraes; Nomura, Cesar Higa; Avila, Luiz Francisco Rodrigues; Giorgi, Maria Clementina Pinto; Soares, Jose; Meneghetti, Jose Claudio; Parga, Jose Rodrigues

    2018-06-01

    Despite advances in non-invasive myocardial perfusion imaging (MPI) evaluation, computed tomography (CT) multiphase MPI protocols have not yet been compared with the highly accurate rubidium-82 positron emission tomography ( 82 RbPET) MPI. Thus, this study aimed to evaluate agreement between 82 RbPET and 320-detector row CT (320-CT) MPI using a multiphase protocol in suspected CAD patients. Forty-four patients referred for MPI evaluation were prospectively enrolled and underwent dipyridamole stress 82 RbPET and multiphase 320-CT MPI (five consecutive volumetric acquisitions during stress). Statistical analyses were performed using the R software. There was high agreement for recognizing summed stress scores ≥ 4 (kappa 0.77, 95% CI 0.55-0.98, p < 0.001) and moderate for detecting SDS ≥ 2 (kappa 0.51, 95% CI 0.23-0.80, p < 0.001). In a per segment analysis, agreement was high for the presence of perfusion defects during stress and rest (kappa 0.75 and 0.82, respectively) and was moderate for impairment severity (kappa 0.58 and 0.65, respectively). The 320-CT protocol was safe, with low radiation burden (9.3 ± 2.4 mSv). There was a significant agreement between dipyridamole stress 320-CT MPI and 82 RbPET MPI in the evaluation of suspected CAD patients of intermediate risk. The multiphase 320-CT MPI protocol was feasible, diagnostic and with relatively low radiation exposure. • Rubidium-82 PET and 320-MDCT can perform MPI studies for CAD investigation. • There is high agreement between rubidium-82 PET and 320-MDCT for MPI assessment. • Multiphase CT perfusion protocols are feasible and with low radiation. • Multiphase CT perfusion protocols can identify image artefacts.

  2. 29 CFR 2530.201-1 - Coverage; general.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 9 2013-07-01 2013-07-01 false Coverage; general. 2530.201-1 Section 2530.201-1 Labor... Provisions § 2530.201-1 Coverage; general. Coverage of the provisions of part 2 of title I of the Act is... § 2510.3-2). Second, the employee benefit plan must be subject to title I of the Act. Coverage for title...

  3. 29 CFR 2530.201-1 - Coverage; general.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 9 2012-07-01 2012-07-01 false Coverage; general. 2530.201-1 Section 2530.201-1 Labor... Provisions § 2530.201-1 Coverage; general. Coverage of the provisions of part 2 of title I of the Act is... § 2510.3-2). Second, the employee benefit plan must be subject to title I of the Act. Coverage for title...

  4. 29 CFR 2530.201-1 - Coverage; general.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 9 2014-07-01 2014-07-01 false Coverage; general. 2530.201-1 Section 2530.201-1 Labor... Provisions § 2530.201-1 Coverage; general. Coverage of the provisions of part 2 of title I of the Act is... § 2510.3-2). Second, the employee benefit plan must be subject to title I of the Act. Coverage for title...

  5. Quantification of both the area-at-risk and acute myocardial infarct size in ST-segment elevation myocardial infarction using T1-mapping.

    PubMed

    Bulluck, Heerajnarain; Hammond-Haley, Matthew; Fontana, Marianna; Knight, Daniel S; Sirker, Alex; Herrey, Anna S; Manisty, Charlotte; Kellman, Peter; Moon, James C; Hausenloy, Derek J

    2017-08-01

    A comprehensive cardiovascular magnetic resonance (CMR) in reperfused ST-segment myocardial infarction (STEMI) patients can be challenging to perform and can be time-consuming. We aimed to investigate whether native T1-mapping can accurately delineate the edema-based area-at-risk (AAR) and post-contrast T1-mapping and synthetic late gadolinium (LGE) images can quantify MI size at 1.5 T. Conventional LGE imaging and T2-mapping could then be omitted, thereby shortening the scan duration. Twenty-eight STEMI patients underwent a CMR scan at 1.5 T, 3 ± 1 days following primary percutaneous coronary intervention. The AAR was quantified using both native T1 and T2-mapping. MI size was quantified using conventional LGE, post-contrast T1-mapping and synthetic magnitude-reconstructed inversion recovery (MagIR) LGE and synthetic phase-sensitive inversion recovery (PSIR) LGE, derived from the post-contrast T1 maps. Native T1-mapping performed as well as T2-mapping in delineating the AAR (41.6 ± 11.9% of the left ventricle [% LV] versus 41.7 ± 12.2% LV, P = 0.72; R 2 0.97; ICC 0.986 (0.969-0.993); bias -0.1 ± 4.2% LV). There were excellent correlation and inter-method agreement with no bias, between MI size by conventional LGE, synthetic MagIR LGE (bias 0.2 ± 2.2%LV, P = 0.35), synthetic PSIR LGE (bias 0.4 ± 2.2% LV, P = 0.060) and post-contrast T1-mapping (bias 0.3 ± 1.8% LV, P = 0.10). The mean scan duration was 58 ± 4 min. Not performing T2 mapping (6 ± 1 min) and conventional LGE (10 ± 1 min) would shorten the CMR study by 15-20 min. T1-mapping can accurately quantify both the edema-based AAR (using native T1 maps) and acute MI size (using post-contrast T1 maps) in STEMI patients without major cardiovascular risk factors. This approach would shorten the duration of a comprehensive CMR study without significantly compromising on data acquisition and would obviate the need to perform T2 maps and LGE imaging.

  6. Systemic pretreatment with dimethyloxalylglycine increases myocardial HIF-1α and VEGF production and improves functional recovery after acute ischemia/reperfusion.

    PubMed

    Poynter, Jeffrey A; Manukyan, Mariuxi C; Wang, Yue; Brewster, Benjamin D; Herrmann, Jeremy L; Weil, Brent R; Abarbanell, Aaron M; Meldrum, Daniel R

    2011-08-01

    Stem cells protect the heart from ischemic damage in part by the release of cytoprotective growth factors, particularly vascular endothelial growth factor (VEGF). Production of VEGF is regulated in part by levels of the transcription factor hypoxia inducible factor 1-α (HIF-1α). Dimethyloxalylglycine (DMOG) prevents the deactivation of HIF-1α and increases VEGF production. However, the effects of systemic DMOG treatment on myocardial tolerance for ischemia are unknown. We hypothesized that systemic pretreatment with DMOG would improve myocardial ischemic tolerance. To study this hypothesis, adult male rats were randomly given an intraperitoneal injection of DMOG (40 mg/kg in 1 mL saline, n = 5) or saline (1 mL, n = 6) 24 h before cardiectomy and isolated heart perfusion. All hearts were subjected to 15 min equilibration, 25 min ischemia and 40 min reperfusion. Myocardial function was continuously monitored. Following reperfusion, myocardial homogenates were analyzed for HIF-1α and VEGF production. We observed that hearts in the DMOG group exhibited greater recovery of left ventricular developed pressure LVDP, +dP/dt and -dP/dt. Myocardial HIF-1α and VEGF levels were increased by DMOG therapy. In conclusion, systemic pretreatment with DMOG augments post-ischemic myocardial functional recovery through increased HIF-1α levels and greater VEGF production. Copyright © 2011 Mosby, Inc. All rights reserved.

  7. [The relation between the low T3 syndrome in the clinical course of myocardial infarction and heart failure].

    PubMed

    Frączek, Magdalena Maria; Gackowski, Andrzej; Przybylik-Mazurek, Elwira; Nessler, Jadwiga

    2016-06-01

    It has been proven that either excess or deficiency of thyroid hormones has harmful influence on the cardiovascular system function. On the other hand, severe systemic conditions like myocardial infarction or severe heart failure may affect thyroid hormones secretion and their peripheral conversion, leading to low T3 syndrome. Amongst many mechanisms causing T4 to T3 conversion disturbances, important role plays decreased activity of D1 deiodinase and increased activity of D3 deiodinase. The animal research confirmed that thyroid hormones influence cardiomiocytes phenotype and morphology. They inhibit inflammation, apoptosis and cardiac remodelling after myocardial infarction. It was also proven that free triiodothyronine similarly to brain natriuretic peptide predict long-term prognosis in chronic and acute heart failure patients. Potential influence of low T3 syndrome on the course of myocardial infarction and heart failure may have significant impact on the future research on individualization of myocardial infarction and heart failure treatment depending on patient's thyroid status. © 2016 MEDPRESS.

  8. Diagnostic Performance of Artificial Neural Network for Detecting Ischemia in Myocardial Perfusion Imaging.

    PubMed

    Nakajima, Kenichi; Matsuo, Shinro; Wakabayashi, Hiroshi; Yokoyama, Kunihiko; Bunko, Hisashi; Okuda, Koichi; Kinuya, Seigo; Nyström, Karin; Edenbrandt, Lars

    2015-01-01

    The purpose of this study was to apply an artificial neural network (ANN) in patients with coronary artery disease (CAD) and to characterize its diagnostic ability compared with conventional visual and quantitative methods in myocardial perfusion imaging (MPI). A total of 106 patients with CAD were studied with MPI, including multiple vessel disease (49%), history of myocardial infarction (27%) and coronary intervention (30%). The ANN detected abnormal areas with a probability of stress defect and ischemia. The consensus diagnosis based on expert interpretation and coronary stenosis was used as the gold standard. The left ventricular ANN value was higher in the stress-defect group than in the no-defect group (0.92±0.11 vs. 0.25±0.32, P<0.0001) and higher in the ischemia group than in the no-ischemia group (0.70±0.40 vs. 0.004±0.032, P<0.0001). Receiver-operating characteristics curve analysis showed comparable diagnostic accuracy between ANN and the scoring methods (0.971 vs. 0.980 for stress defect, and 0.882 vs. 0.937 for ischemia, both P=NS). The relationship between the ANN and defect scores was non-linear, with the ANN rapidly increased in ranges of summed stress score of 2-7 and summed defect score of 2-4. Although the diagnostic ability of ANN was similar to that of conventional scoring methods, the ANN could provide a different viewpoint for judging abnormality, and thus is a promising method for evaluating abnormality in MPI.

  9. 40 CFR 243.201-1 - Requirement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... protect the health and safety of personnel associated with the operation. ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Requirement. 243.201-1 Section 243.201-1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR...

  10. 40 CFR 243.201-1 - Requirement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... protect the health and safety of personnel associated with the operation. ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Requirement. 243.201-1 Section 243.201-1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR...

  11. 40 CFR 243.201-1 - Requirement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... protect the health and safety of personnel associated with the operation. ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Requirement. 243.201-1 Section 243.201-1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR...

  12. 40 CFR 243.201-1 - Requirement.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... protect the health and safety of personnel associated with the operation. ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Requirement. 243.201-1 Section 243.201-1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR...

  13. 40 CFR 243.201-1 - Requirement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... protect the health and safety of personnel associated with the operation. ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Requirement. 243.201-1 Section 243.201-1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR...

  14. Review of cardiovascular imaging in the Journal of Nuclear Cardiology in 2017. Part 2 of 2: Myocardial perfusion imaging.

    PubMed

    Hage, Fadi G; AlJaroudi, Wael A

    2018-04-16

    In 2017, the Journal of Nuclear Cardiology published many high-quality articles. In this review, we will summarize a selection of these articles to provide a concise review of the main advancements that have recently occurred in the field. In the first article of this 2-part series, we focused on publications dealing with positron emission tomography, computed tomography, and magnetic resonance. This review will place emphasis on myocardial perfusion imaging using single-photon emission computed tomography summarizing advances in the field including prognosis, safety and tolerability, the impact of imaging on management, and the use of novel imaging protocols.

  15. Use of carbonated water in reduction of adjacent gastric activity in 456 consecutive technetium-99m myocardial perfusion imaging studies.

    PubMed

    Thomas, Dustin M; Lee, Joshua S; Charmforoush, Anthony; Rubal, Bernard J; Rosenblatt, Stephen A; Butler, Joshua T; Clemenshaw, Michael; Cheezum, Michael K; Slim, Ahmad M

    2015-12-01

    Small, observational trials have suggested a reduction in adjacent gastric activity with ingestion of soda water in myocardial perfusion imaging (MPI). We report our findings prior to and after implementation of soda water in 467 consecutive MPI studies. Consecutive MPI studies performed at a high-volume facility referred for vasodilator (VD) or exercise treadmill testing (ETT) were retrospectively reviewed before and after implementation of the soda water protocol. Patients undergoing the soda water protocol received 100 ml of soda water administered 30 min prior to image acquisition and after stress. Studies were performed using a same day rest/stress protocol. Incidence of adjacent gastric activity, diaphragmatic attenuation, stress and rest perfusion defects, and major adverse cardiovascular events (MACE) outcomes defined as death, myocardial infarction, stroke, reevaluation for chest pain, and late revascularization (>90 days from MPI) were abstracted using International Classification of Diseases, Ninth Revision (ICD-9) search. Two hundred and eighteen studies were performed prior to implementation of the soda water protocol and 249 studies were performed with the use of soda water. Baseline demographic data were equal between the groups with the exception of more patients undergoing VD stress receiving soda water (p < 0.001). Soda water was not associated with a decreased incidence of adjacent gastric activity with stress (54.7% versus 61.9% with no soda water, p = 0.129) or rest (68.6% versus 69.5% with no soda water, p = 0.919) imaging. Less adjacent gastric activity was observed with patients undergoing ETT who received soda water (42.5% versus 56.9% with no soda water, p = 0.031), but no difference was observed between the groups with VD stress (69.0% versus 68.1% with no soda water, p = 1.000). The use of soda water prior to technetium-99m MPI was associated with lower rates of adjacent gastric activity only in patients undergoing ETT stress but not

  16. [Effect of Moxibustion Preconditioning with Seed-sized Moxa Cones on Myocardial Infarction Size and Beclin 1 Expression in Myocardial Ischemia-reperfusion Injury Rats].

    PubMed

    Bai, Hua; Lu, Sheng-Feng; Chen, Wan-Ying; Zhong, Ze-Hao; Gu, Yi-Huang

    2017-12-25

    To observe the effect of moxibustion (Moxi) preconditioning with seed-sized moxa cones on myocardial ischemia-reperfusion injury (MI/RI) at different stages, and to analyze the correlation between this effect and the expression of autophagy related protein Beclin 1. This study contains two parts: 1) changes of myocardial pathological injury and percentages of myocardial infarcted area at different time-points after modeling and Moxi intervention, and 2) effect of Moxi on contents of serum cardiac troponin T(cTnT) and expression of myocardial Bcl-2, Bax and Beclin 1 proteins. In the first part, 42 SD rats were randomly divided into model group, 1 day (d) Moxi group, 2 d Moxi group, 3 d Moxi group,4 d Moxi group, 5 d Moxi group and 7 d Moxi group. The model of MI/RI was established by ligating the left anterior descending coronary artery (LAD) for 30 min and reperfusion for 240 min. The electrocardiogram (ECG) of standard limb lead Ⅱ was monitored and the heart was taken 4 h after reperfusion for examining myocardial infarcted size with triphenyl tetrazolium chloride (TTC) staining. In the second part, 48 SD rats were randomized into sham-operation, model, moxibustion and autophagy inhibitor (3-MA) groups, with 12 rats in each group. The serum cTnT level was assayed and histopathological changes of the myocardial tissue below the ligation site were examined with HE staining, and the expression levels of Bcl-2, Bax and Beclin 1 proteins in the myocardial tissue below the LAD-ligated site were detected using Western blot. Compared with the model group, the percentages of myocardial infarcted area were significantly decreased in the 4 d, 5 d and 7 d Moxi groups ( P <0.05), but without significant differences among the 3 Moxi groups ( P >0.05). The state of MI-induced breakage and disordered arrangement of myocardial fibers with interstitial edema and inflammatory cell infiltration at the MI stage in the Moxi group and at the reperfusion stage in the autophagy

  17. MR contrast media for myocardial viability, microvascular integrity and perfusion.

    PubMed

    Saeed, M; Wendland, M F; Watzinger, N; Akbari, H; Higgins, C B

    2000-06-01

    Cardiovascular imaging requires an appreciation of rapidly evolving MR imaging sequences as well as careful utilization of intravascular, extracellular and intracellular MR contrast media. At the present time, clinical studies are restricted to the use of extracellular MR contrast media. MR imaging has the potential to noninvasively measure multiple parameters of the cardiovascular system in a single imaging session. Recent advances in fast and ultrafast MR imaging have considerably enhanced the capability of this technique, beyond the assessment of left ventricular wall motion and morphology into visualization of the coronary arteries and measurement of blood flow. During the course of the last several years, multiple strategies for imaging viable myocardium have been developed and validated using MR contrast media. Contrast enhanced dynamic MR imaging provides information regarding microvascular integrity and perfusion. Because these information can be provided noninvasively by MR imaging, repeated measurements can be performed in longitudinal studies to monitor the progression or regression of myocardial injury. Similar studies are needed to examine the effects of newly developed cardioprotective therapeutics. Development of suitable intravascular MR contrast medium may be essential for visualization of the coronary arteries and interventional therapies. MR imaging may emerge as one-stop-shop for evaluating the heart and coronary system. This capability will make MR imaging cost-effective in the first decade of this millennium.

  18. Quantification of myocardial area at risk in the absence of collateral flow: the validation of angiographic scores by myocardial perfusion single-photon emission computed tomography.

    PubMed

    Rodríguez-Palomares, José F; Alonso, Albert; Martí, Gerard; Aguadé-Bruix, Santiago; González-Alujas, M T; Romero-Farina, Guillermo; Candell-Riera, Jaume; García del Blanco, Bruno; Evangelista, Artur; García-Dorado, David

    2013-02-01

    Our study aimed to compare the area at risk (AAR) determined by single-photon emission computed tomography (SPECT) with the Bypass Angioplasty Revascularization Investigation (BARI) and modified Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease (APPROACH) angiographic scores in the setting of patients undergoing coronary angioplasty for either unstable angina or an STEMI. Radionuclide myocardial perfusion imaging prior to reperfusion has classically been the most widely practised technique for assessing the AAR and has been successfully used to compare the efficacy of various reperfusion strategies in patients with an ST-segment elevation myocardial infarction (STEMI). The BARI and modified APPROACH scores are angiographic methods widely used to provide a rapid estimation of the AAR; however, they have not been directly validated with myocardial perfusion single-photon emission computed tomography (SPECT). Fifty-five patients with no previous myocardial infarction who underwent coronary angioplasty for single-vessel disease (unstable angina: n = 25 or an STEMI: n = 30) with no evidence of collaterals (Rentrop Collateral Score <2) were included in a prospective study. In STEMI patients, the (99m)Tc-tetrofosmin was injected prior to opening of the occluded vessel and, in patients with unstable angina after 10-15 seconds of balloon inflation. Acquisition was performed with a dual-head gammacamera with a low-energy and high-resolution collimator. A total of 60 projections were acquired using a non-circular orbit. No attenuation or scatter correction was used. Maximal contours of hypoperfusion regions corresponding to each coronary artery occlusion were delineated over a polar map of 17 segments and compared with the estimated AAR determined by two experienced interventional cardiologists using both angiographic scores. Mean AAR percentage in SPECT was 35.0 (10.0%-56.0%). A high correlation was found between BARI and APPROACH scores (r = 0.9, P

  19. Myocardial function and perfusion in the CREST syndrome variant of progressive systemic sclerosis. Exercise radionuclide evaluation and comparison with diffuse scleroderma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Follansbee, W.P.; Curtiss, E.I.; Medsger, T.A. Jr.

    1984-09-01

    Myocardial function and perfusion were evaluated in 22 patients with progressive systemic sclerosis with the CREST syndrome using exercise and radionuclide techniques, pulmonary function testing, and chest roentgenography. The results were compared with a similar study of 26 patients with progressive systemic sclerosis with diffuse scleroderma. The prevalence of thallium perfusion abnormalities was similar in the groups with CREST syndrome and diffuse scleroderma, (64 percent versus 77 percent), but the defects were significantly smaller in the CREST syndrome (p less than 0.01). Reperfusion thallium defects in the absence of extramural coronary artery disease were seen in 38 percent of patientsmore » with diffuse scleroderma. This finding was not seen in any of the patients with the CREST syndrome. In diffuse scleroderma, abnormalities of both right and left ventricular function were related to larger thallium perfusion defects. In the CREST syndrome, abnormalities of left ventricular function were minor, were seen only during exercise, and were unrelated to thallium perfusion defects. Abnormal resting right ventricular function was seen in 36 percent of the patients with the CREST syndrome and was associated with an isolated decrease in diffusing capacity of carbon monoxide. It is concluded that the cardiac manifestations of the CREST syndrome are distinct from those found in diffuse scleroderma. Unlike diffuse scleroderma, abnormalities of left ventricular function in the CREST syndrome are minor and are unrelated to abnormalities of coronary perfusion. Right ventricular dysfunction in the CREST syndrome appears to be primarily related to pulmonary vascular disease.« less

  20. Use of bio-informatics assessment schema (BIAS) to improve diagnosis and prognosis of myocardial perfusion data: results from the NHLBI-sponsored women’s ischemia syndrome evaluation (WISE)

    PubMed Central

    Pohost, Gerald M.; Bairey Merz, C. Noel; Shaw, Leslee J.; Sopko, George; Rogers, William J.; Sharaf, Barry L.; Pepine, Carl J.; Thompson, Diane V.; Rayarao, Geetha; Tauxe, Lindsey; Kelsey, Sheryl F.; Biederman, Robert W. W.

    2016-01-01

    Background We introduce an algorithmic approach to optimize diagnostic and prognostic value of gated cardiac single photon emission computed tomography (SPECT) and magnetic resonance (MR) myocardial perfusion imaging (MPI) modalities in women with suspected myocardial ischemia. The novel approach: bio-informatics assessment schema (BIAS) forms a mathematical model utilizing MPI data and cardiac metrics generated by one modality to predict the MPI status of another modality. The model identifies cardiac features that either enhance or mask the image-based evidence of ischemia. For each patient, the BIAS model value is used to set an appropriate threshold for the detection of ischemia. Methods Women (n=130), with symptoms and signs of suspected myocardial ischemia, underwent MPI assessment for regional perfusion defects using two different modalities: gated SPECT and MR. To determine perfusion status, MR data were evaluated qualitatively (MRIQL) and semi-quantitatively (MRISQ) while SPECT data were evaluated using conventional clinical criteria. Evaluators were masked to results of the alternate modality. These MPI status readings were designated “original”. Two regression models designated “BIAS” models were generated to model MPI status obtained with one modality (e.g., MRI) compared with a second modality (e.g., SPECT), but importantly, the BIAS models did not include the primary Original MPI reading of the predicting modality. Instead, the BIAS models included auxiliary measurements like left ventricular chamber volumes and myocardial wall thickness. For each modality, the BIAS model was used to set a progressive threshold for interpretation of MPI status. Women were then followed for 38±14 months for the development of a first major adverse cardiovascular event [MACE: CV death, nonfatal myocardial infarction (MI) or hospitalization for heart failure]. Original and BIAS-augmented perfusion status were compared in their ability to detect coronary artery

  1. A single CT for attenuation correction of both rest and stress SPECT myocardial perfusion imaging: a retrospective feasibility study

    PubMed Central

    Ahlman, Mark A; Nietert, Paul J; Wahlquist, Amy E; Serguson, Jill M; Berry, Max W; Suranyi, Pal; Liu, Songtao; Spicer, Kenneth M

    2014-01-01

    Purpose: In the effort to reduce radiation exposure to patients undergoing myocardial perfusion imaging (MPI) with SPECT/CT, we evaluate the feasibility of a single CT for attenuation correction (AC) of single-day rest (R)/stress (S) perfusion. Methods: Processing of 20 single isotope and 20 dual isotope MPI with perfusion defects were retrospectively repeated in three steps: (1) the standard method using a concurrent R-CT for AC of R-SPECT and S-CT for S-SPECT; (2) the standard method repeated; and (3) with the R-CT used for AC of S-SPECT, and the S-CT used for AC of R-SPECT. Intra-Class Correlation Coefficients (ICC) and Choen’s kappa were used to measure intra-operator variability in sum scoring. Results: The highest level of intra-operator reliability was seen with the reproduction of the sum rest score (SRS) and sum stress score (SSS) (ICC > 95%). ICCs were > 85% for SRS and SSS when alternate CTs were used for AC, but when sum difference scores were calculated, ICC values were much lower (~22% to 27%), which may imply that neither CT substitution resulted in a reproducible difference score. Similar results were seen when evaluating dichotomous outcomes (sum scores difference of ≥ 4) when comparing different processing techniques (kappas ~0.32 to 0.43). Conclusions: When a single CT is used for AC of both rest and stress SPECT, there is disproportionately high variability in sum scoring that is independent of user error. This information can be used to direct further investigation in radiation reduction for common imaging exams in nuclear medicine. PMID:24482701

  2. T1 and T2 Mapping in Cardiology: "Mapping the Obscure Object of Desire".

    PubMed

    Mavrogeni, Sophie; Apostolou, Dimitris; Argyriou, Panayiotis; Velitsista, Stella; Papa, Lilika; Efentakis, Stelios; Vernardos, Evangelos; Kanoupaki, Mikela; Kanoupakis, George; Manginas, Athanassios

    The increasing use of cardiovascular magnetic resonance (CMR) is based on its capability to perform biventricular function assessment and tissue characterization without radiation and with high reproducibility. The use of late gadolinium enhancement (LGE) gave the potential of non-invasive biopsy for fibrosis quantification. However, LGE is unable to detect diffuse myocardial disease. Native T1 mapping and extracellular volume fraction (ECV) provide knowledge about pathologies affecting both the myocardium and interstitium that is otherwise difficult to identify. Changes of myocardial native T1 reflect cardiac diseases (acute coronary syndromes, infarction, myocarditis, and diffuse fibrosis, all with high T1) and systemic diseases such as cardiac amyloid (high T1), Anderson-Fabry disease (low T1), and siderosis (low T1). The ECV, an index generated by native and post-contrast T1 mapping, measures the cellular and extracellular interstitial matrix (ECM) compartments. This myocyte-ECM dichotomy has important implications for identifying specific therapeutic targets of great value for heart failure treatment. On the other hand, T2 mapping is superior compared with myocardial T1 and ECM for assessing the activity of myocarditis in recent-onset heart failure. Although these indices can significantly affect the clinical decision making, multicentre studies and a community-wide approach (including MRI vendors, funding, software, contrast agent manufacturers, and clinicians) are still missing. © 2017 S. Karger AG, Basel.

  3. 40 CFR 240.201-1 - Requirement.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... chemical and biological characteristics of the waste, environmental and health effects, and the safety of... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Requirement. 240.201-1 Section 240.201-1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR...

  4. 40 CFR 240.201-1 - Requirement.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... chemical and biological characteristics of the waste, environmental and health effects, and the safety of... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Requirement. 240.201-1 Section 240.201-1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR...

  5. 40 CFR 240.201-1 - Requirement.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... chemical and biological characteristics of the waste, environmental and health effects, and the safety of... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Requirement. 240.201-1 Section 240.201-1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR...

  6. 45 CFR 201.1 - General definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 2 2011-10-01 2011-10-01 false General definitions. 201.1 Section 201.1 Public Welfare Regulations Relating to Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS TO STATES FOR PUBLIC...

  7. 45 CFR 201.1 - General definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 2 2013-10-01 2012-10-01 true General definitions. 201.1 Section 201.1 Public Welfare Regulations Relating to Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS TO STATES FOR PUBLIC...

  8. 45 CFR 201.1 - General definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 2 2014-10-01 2012-10-01 true General definitions. 201.1 Section 201.1 Public Welfare Regulations Relating to Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS TO STATES FOR PUBLIC...

  9. 45 CFR 201.1 - General definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 2 2012-10-01 2012-10-01 false General definitions. 201.1 Section 201.1 Public Welfare Regulations Relating to Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS TO STATES FOR PUBLIC...

  10. 45 CFR 201.1 - General definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false General definitions. 201.1 Section 201.1 Public Welfare Regulations Relating to Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS TO STATES FOR PUBLIC...

  11. Fully quantitative pixel-wise analysis of cardiovascular magnetic resonance perfusion improves discrimination of dark rim artifact from perfusion defects associated with epicardial coronary stenosis.

    PubMed

    Ta, Allison D; Hsu, Li-Yueh; Conn, Hannah M; Winkler, Susanne; Greve, Anders M; Shanbhag, Sujata M; Chen, Marcus Y; Patricia Bandettini, W; Arai, Andrew E

    2018-03-08

    Dark rim artifacts in first-pass cardiovascular magnetic resonance (CMR) perfusion images can mimic perfusion defects and affect diagnostic accuracy for coronary artery disease (CAD). We evaluated whether quantitative myocardial blood flow (MBF) can differentiate dark rim artifacts from true perfusion defects in CMR perfusion. Regadenoson perfusion CMR was performed at 1.5 T in 76 patients. Significant CAD was defined by quantitative invasive coronary angiography (QCA) ≥ 50% diameter stenosis. Non-significant CAD (NonCAD) was defined as stenosis by QCA < 50% diameter stenosis or computed tomographic coronary angiography (CTA) < 30% in all major epicardial arteries. Dark rim artifacts had study specific and guideline-based definitions for comparison purposes. MBF was quantified at the pixel-level and sector-level. In a NonCAD subgroup with dark rim artifacts, stress MBF was lower in the subendocardial than midmyocardial and epicardial layers (2.17 ± 0.61 vs. 3.06 ± 0.75 vs. 3.24 ± 0.80 mL/min/g, both p < 0.001) and was also 30% lower than in remote regions (2.17 ± 0.61 vs. 2.83 ± 0.67 mL/min/g, p < 0.001). However, subendocardial stress MBF in dark rim artifacts was 37-56% higher than in true perfusion defects (2.17 ± 0.61 vs. 0.95 ± 0.43 mL/min/g, p < 0.001). Absolute stress MBF differentiated CAD from NonCAD with an accuracy ranging from 86 to 89% (all p < 0.001) using pixel-level analyses. Similar results were seen at a sector level. Quantitative stress MBF is lower in dark rim artifacts than remote myocardium but significantly higher than in true perfusion defects. If confirmed in larger series, this approach may aid the interpretation of clinical stress perfusion exams. ClinicalTrials.gov Identifier: NCT00027170 ; first posted 11/28/2001; updated 11/27/2017.

  12. Pharmacologic Effects of Cannabidiol on Acute Reperfused Myocardial Infarction in Rabbits: Evaluated With 3.0T Cardiac Magnetic Resonance Imaging and Histopathology.

    PubMed

    Feng, Yuanbo; Chen, Feng; Yin, Ting; Xia, Qian; Liu, Yewei; Huang, Gang; Zhang, Jian; Oyen, Raymond; Ni, Yicheng

    2015-10-01

    Cannabidiol (CBD) has anti-inflammatory effects. We explored its therapeutic effects on cardiac ischemia-reperfusion injury with an experimental imaging platform. Reperfused acute myocardial infarction (AMI) was induced in rabbits with a 90-minute coronary artery occlusion followed by 24-hour reperfusion. Before reperfusion, rabbits received 2 intravenous doses of 100 μg/kg CBD (n = 10) or vehicle (control, n = 10). Evans blue was intravenously injected for later detection of the AMI core. Cardiac magnetic resonance imaging was performed to evaluate cardiac morphology and function. After euthanasia, blood troponin I (cTnI) was assessed, and the heart was excised and infused with multifunctional red iodized oil dye. The heart was sliced for digital radiography to quantify the perfusion density rate, area at risk (AAR), and myocardial salvage index, followed by histomorphologic staining. Compared with controls, CBD treatment improved systolic wall thickening (P < 0.05), significantly increased blood flow in the AAR (P < 0.05), significantly decreased microvascular obstruction (P < 0.05), increased the perfusion density rate by 1.7-fold, lowered the AMI core/AAR ratio (P < 0.05), and increased the myocardial salvage index (P < 0.05). These improvements were associated with reductions in serum cTnI, cardiac leukocyte infiltration, and myocellular apoptosis (P < 0.05). Thus, CBD therapy reduced AMI size and facilitated restoration of left ventricular function. We demonstrated that this experimental platform has potential theragnostic utility.

  13. Age Dependency of Myocardial Triglyceride Content: A 3T High-Field 1H-MR Spectroscopy Study.

    PubMed

    Petritsch, B; Gassenmaier, T; Kunz, A S; Donhauser, J; Goltz, J P; Bley, T A; Horn, M

    2015-11-01

    The role of myocardial triglyceride (mTG) content in the aging human heart is not entirely understood. The aim of this study was to measure concentrations of mTG content from healthy volunteers and to determine the association between age, mTG content and systolic heart function. Furthermore, the technical stability of the (1)H-magnetic resonance spectroscopy ((1)H-MRS) and the reliability of peak evaluation at 3 T were evaluated. The total study population of 47 healthy volunteers was divided into 4 age classes, according to the age of the subjects (1(st) cohort 20 - 29 years (yrs.), n = 20; 2(nd) cohort 30 - 39 yrs., n = 10; 3(rd) cohort 40 - 49 yrs., n = 9; 4(th) cohort 50 - 60 yrs., n = 8). Cardiac MRI and double triggered (1)H-MRS of the myocardium were consecutively performed using a 3 T scanner. Each participant underwent spectroscopic measurements twice in the same investigation. mTG content increases with age. The correlation of age and mTG is minimal (r = 0.48; p < 0.001). The following age-averaged mTG content values expressed as % of mTG signal compared to the water signal were determined for each cohort: 1(st) cohort 0.25 % (± 0.17); 2(nd) cohort 0.48 % (± 0.30); 3(rd) cohort 0.48 % (± 0.18); 4(th) cohort 0.77 % (± 0.70). There was no significant correlation (r = 0.04; p = n.s.) between LV mass and mTG content in healthy volunteers. Within our cohorts, no effects of age or mTG content on systolic heart function were seen (r = - 0.01; p = n.s.). The intraclass correlation coefficient of spectroscopic measurements was high (r = 0.965; p < 0.001). Myocardial TG content increases with age. The normal age-dependent concentration ranges of myocardial lipid metabolites reported in this study may be helpful for the correction of acquired (1)H-MRS data in patients when evaluating metabolic and cardiovascular diseases in future magnetic resonance spectroscopy studies.

  14. 14 CFR 201.1 - Formal requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Formal requirements. 201.1 Section 201.1 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC... papers. (b) Any person desiring to provide air transportation as a commuter air carrier must comply with...

  15. Patient-specific coronary blood supply territories for quantitative perfusion analysis

    PubMed Central

    Zakkaroff, Constantine; Biglands, John D.; Greenwood, John P.; Plein, Sven; Boyle, Roger D.; Radjenovic, Aleksandra; Magee, Derek R.

    2018-01-01

    Abstract Myocardial perfusion imaging, coupled with quantitative perfusion analysis, provides an important diagnostic tool for the identification of ischaemic heart disease caused by coronary stenoses. The accurate mapping between coronary anatomy and under-perfused areas of the myocardium is important for diagnosis and treatment. However, in the absence of the actual coronary anatomy during the reporting of perfusion images, areas of ischaemia are allocated to a coronary territory based on a population-derived 17-segment (American Heart Association) AHA model of coronary blood supply. This work presents a solution for the fusion of 2D Magnetic Resonance (MR) myocardial perfusion images and 3D MR angiography data with the aim to improve the detection of ischaemic heart disease. The key contribution of this work is a novel method for the mediated spatiotemporal registration of perfusion and angiography data and a novel method for the calculation of patient-specific coronary supply territories. The registration method uses 4D cardiac MR cine series spanning the complete cardiac cycle in order to overcome the under-constrained nature of non-rigid slice-to-volume perfusion-to-angiography registration. This is achieved by separating out the deformable registration problem and solving it through phase-to-phase registration of the cine series. The use of patient-specific blood supply territories in quantitative perfusion analysis (instead of the population-based model of coronary blood supply) has the potential of increasing the accuracy of perfusion analysis. Quantitative perfusion analysis diagnostic accuracy evaluation with patient-specific territories against the AHA model demonstrates the value of the mediated spatiotemporal registration in the context of ischaemic heart disease diagnosis. PMID:29392098

  16. Thymoquinone Attenuates Myocardial Ischemia/Reperfusion Injury Through Activation of SIRT1 Signaling.

    PubMed

    Lu, Yunyang; Feng, Yingda; Liu, Dan; Zhang, Zhiran; Gao, Kai; Zhang, Wei; Tang, Haifeng

    2018-06-15

    Myocardial ischemia/reperfusion (MI/R) injury is a leading factor responsible for damage in myocardial infarction, resulting in additional injury to cardiac tissues involved in oxidative stress, inflammation, and apoptosis. Thymoquinone (TQ), the main constituent of Nigella sativa L. seeds, has been reported to possess various biological activities. However, few reports regarding myocardial protection are available at present. Therefore, this study was conducted aiming to investigate the protective effect of TQ against MI/R injury and to clarify its potential mechanism. MI/R injury models of isolated rat hearts and neonatal rat cardiomyocytes were established. The Langendorff isolated perfused heart system, triphenyltetrazolium chloride staining, gene transfection, TransLaser scanning confocal microscopy, and western blotting were employed to evaluate the cardioprotection effect of TQ against MI/R injury. Compared with the MI/R group, TQ treatment could remarkably improve left ventricular function, decrease myocardial infarct size and production of lactate dehydrogenase (LDH), and attenuate mitochondrial oxidative damage by elevating superoxide dismutase (SOD) activity and reducing production of hydrogen peroxide (H2O2) and malonaldehyde (MDA). Moreover, the cardioprotective effect of TQ was accompanied by up-regulated expression of SIRT1 and inhibition of p53 acetylation. Additionally, TQ treatment could also enhance mitochondrial function and reduce the number of apoptotic cardiomyocytes. Nonetheless, the cardioprotective effect of TQ could be mitigated by SIRT1 inhibitor sirtinol and SIRT1 siRNA, respectively, which was achieved through inhibition of the SIRT1 signaling pathway. The findings in this study demonstrate that TQ is efficient in attenuating MI/R injury through activation of the SIRT1 signaling pathway, which can thus reduce mitochondrial oxidative stress damage and cardiomyocyte apoptosis. © 2018 The Author(s). Published by S. Karger AG, Basel.

  17. ONC201 selectively induces apoptosis in cutaneous T-cell lymphoma cells via activating pro-apoptotic integrated stress response and inactivating JAK/STAT and NF-κB pathways

    PubMed Central

    Ni, Xiao; Zhang, Xiang; Hu, Cheng-Hui; Langridge, Timothy; Tarapore, Rohinton S.; Allen, Joshua E.; Oster, Wolfgang; Duvic, Madeleine

    2017-01-01

    Cutaneous T-cell lymphomas (CTCLs) are extremely symptomatic and still incurable, and more effective and less toxic therapies are urgently needed. ONC201, an imipridone compound, has shown efficacy in pre-clinical studies in multiple advanced cancers. This study was to evaluate the anti-tumor activity of ONC201 on CTCL cells. The effect of ONC201 on the cell growth and apoptosis were evaluated in CTCL cell lines (n=8) and primary CD4+ malignant T cells isolated from CTCL patients (n=5). ONC201 showed a time-dependent cell growth inhibition in all treated cell lines with a concentration range of 1.25-10.0 μM. ONC201 also induced apoptosis in tested cells with a narrow concentration range of 2.5-10.0 μM, evidenced by increased Annexin V+ cells, accompanied by accumulated sub-G1 portions. ONC201 only induced apoptosis in CD4+ malignant T cells, not in normal CD4+ T cells. The activating transcription factor 4 (ATF4), a hallmark of integrated stress response, was upregulated in response to ONC201 whereas Akt was downregulated. In addition, molecules in JAK/STAT and NF-κB pathways, as well as IL-32β, were downregulated following ONC201 treatment. Thus, ONC201 exerts a potent and selective anti-tumor effect on CTCL cells. Its efficacy may involve activating integrated stress response through ATF4 and inactivating JAK/STAT and NF-κB pathways. PMID:28977902

  18. ONC201 selectively induces apoptosis in cutaneous T-cell lymphoma cells via activating pro-apoptotic integrated stress response and inactivating JAK/STAT and NF-κB pathways.

    PubMed

    Ni, Xiao; Zhang, Xiang; Hu, Cheng-Hui; Langridge, Timothy; Tarapore, Rohinton S; Allen, Joshua E; Oster, Wolfgang; Duvic, Madeleine

    2017-09-22

    Cutaneous T-cell lymphomas (CTCLs) are extremely symptomatic and still incurable, and more effective and less toxic therapies are urgently needed. ONC201, an imipridone compound, has shown efficacy in pre-clinical studies in multiple advanced cancers. This study was to evaluate the anti-tumor activity of ONC201 on CTCL cells. The effect of ONC201 on the cell growth and apoptosis were evaluated in CTCL cell lines (n=8) and primary CD4 + malignant T cells isolated from CTCL patients (n=5). ONC201 showed a time-dependent cell growth inhibition in all treated cell lines with a concentration range of 1.25-10.0 μM. ONC201 also induced apoptosis in tested cells with a narrow concentration range of 2.5-10.0 μM, evidenced by increased Annexin V + cells, accompanied by accumulated sub-G1 portions. ONC201 only induced apoptosis in CD4 + malignant T cells, not in normal CD4 + T cells. The activating transcription factor 4 (ATF4), a hallmark of integrated stress response, was upregulated in response to ONC201 whereas Akt was downregulated. In addition, molecules in JAK/STAT and NF-κB pathways, as well as IL-32β, were downregulated following ONC201 treatment. Thus, ONC201 exerts a potent and selective anti-tumor effect on CTCL cells. Its efficacy may involve activating integrated stress response through ATF4 and inactivating JAK/STAT and NF-κB pathways.

  19. Myocardial T1 mapping and extracellular volume quantification: a Society for Cardiovascular Magnetic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement

    PubMed Central

    2013-01-01

    Rapid innovations in cardiovascular magnetic resonance (CMR) now permit the routine acquisition of quantitative measures of myocardial and blood T1 which are key tissue characteristics. These capabilities introduce a new frontier in cardiology, enabling the practitioner/investigator to quantify biologically important myocardial properties that otherwise can be difficult to ascertain clinically. CMR may be able to track biologically important changes in the myocardium by: a) native T1 that reflects myocardial disease involving the myocyte and interstitium without use of gadolinium based contrast agents (GBCA), or b) the extracellular volume fraction (ECV)–a direct GBCA-based measurement of the size of the extracellular space, reflecting interstitial disease. The latter technique attempts to dichotomize the myocardium into its cellular and interstitial components with estimates expressed as volume fractions. This document provides recommendations for clinical and research T1 and ECV measurement, based on published evidence when available and expert consensus when not. We address site preparation, scan type, scan planning and acquisition, quality control, visualisation and analysis, technical development. We also address controversies in the field. While ECV and native T1 mapping appear destined to affect clinical decision making, they lack multi-centre application and face significant challenges, which demand a community-wide approach among stakeholders. At present, ECV and native T1 mapping appear sufficiently robust for many diseases; yet more research is required before a large-scale application for clinical decision-making can be recommended. PMID:24124732

  20. Positron-emitting myocardial blood flow tracers and clinical potential.

    PubMed

    Schindler, Thomas H

    2015-01-01

    Positron-emitting myocardial flow radiotracers such as (15)O-water, (13)N-ammonia and (82)Rubidium in conjunction with positron-emission-tomography (PET) are increasingly applied in clinical routine for coronary artery disease (CAD) detection, yielding high diagnostic accuracy, while providing valuable information on cardiovascular (CV) outcome. Owing to a cyclotron dependency of (15)O-water and (13)N-ammonia, their clinical use for PET myocardial perfusion imaging is limited to a few centers. This limitation could be overcome by the increasing use of (82)Rubidium as it can be eluted from a commercially available (82)Strontium generator and, thus, is independent of a nearby cyclotron. Another novel F-18-labeled myocardial flow radiotracer is flurpiridaz which has attracted increasing interest due to its excellent radiotracer characteristics for perfusion and flow imaging with PET. In particular, the relatively long half-life of 109 minutes of flurpiridaz may afford a general application of this radiotracer for PET perfusion imaging comparable to technetium-99m-labeled single-photon emission computed tomography (SPECT). The ability of PET in conjunction with several radiotracers to assess myocardial blood flow (MBF) in ml/g/min at rest and during vasomotor stress has contributed to unravel pathophysiological mechanisms underlying coronary artery disease (CAD), to improve the detection and characterization of CAD burden in multivessel disease, and to provide incremental prognostic information in individuals with subclinical and clinically-manifest CAD. The concurrent evaluation of myocardial perfusion and MBF may lead to a new era of a personalized, image-guided therapy approach that may offer potential to further improve clinical outcome in CV disease patients but needing validation in large-scale clinical trials. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Silent myocardial ischemia in patients with symptomatic intracranial atherosclerosis: associated factors.

    PubMed

    Arenillas, Juan F; Candell-Riera, Jaume; Romero-Farina, Guillermo; Molina, Carlos A; Chacón, Pilar; Aguadé-Bruix, Santiago; Montaner, Joan; de León, Gustavo; Castell-Conesa, Joan; Alvarez-Sabín, José

    2005-06-01

    Optimization of coronary risk evaluation in stroke patients has been encouraged. The relationship between symptomatic intracranial atherosclerosis and occult coronary artery disease (CAD) has not been evaluated sufficiently. We aimed to investigate the prevalence of silent myocardial ischemia in patients with symptomatic intracranial atherosclerosis and to identify factors associated with its presence. From 186 first-ever transient ischemic attack or ischemic stroke patients with intracranial stenoses, 65 fulfilled selection criteria, including angiographic confirmation of a symptomatic atherosclerotic stenosis and absence of known CAD. All patients underwent a maximal-stress myocardial perfusion single-photon emission computed tomography (SPECT). Lipoprotein(a) [Lp(a)], C-reactive protein, and homocysteine (Hcy) levels were determined before SPECT. Stress-rest SPECT detected reversible myocardial perfusion defects in 34 (52%) patients. Vascular risk factors associated with a pathologic SPECT were hypercholesterolemia (P=0.045), presence of >2 risk factors (P=0.004) and high Lp(a) (P=0.023) and Hcy levels (P=0.018). Ninety percent of patients with high Lp(a) and Hcy levels had a positive SPECT. Existence of a stenosed intracranial internal carotid artery (ICA; odds ratio [OR], 7.22, 2.07 to 25.23; P=0.002) and location of the symptomatic stenosis in vertebrobasilar arteries (OR, 4.89, 1.19 to 20.12; P=0.027) were independently associated with silent myocardial ischemia after adjustment by age, sex, and risk factors. More than 50% of the patients with symptomatic intracranial atherosclerosis and not overt CAD show myocardial perfusion defects on stress-rest SPECT. Stenosed intracranial ICA, symptomatic vertebrobasilar stenosis and presence of high Lp(a) and Hcy levels may characterize the patients at a higher risk for occult CAD.

  2. VO(2peak), myocardial hypertrophy, and myocardial blood flow in endurance-trained men.

    PubMed

    Laaksonen, Marko S; Heinonen, Ilkka; Luotolahti, Matti; Knuuti, Juhani; Kalliokoski, Kari K

    2014-08-01

    Endurance training induces cardiovascular and metabolic adaptations, leading to enhanced endurance capacity and exercise performance. Previous human studies have shown contradictory results in functional myocardial vascular adaptations to exercise training, and we hypothesized that this may be related to different degrees of hypertrophy in the trained heart. We studied the interrelationships between peak aerobic power (V˙O2peak), myocardial blood flow (MBF) at rest and during adenosine-induced vasodilation, and parameters of myocardial hypertrophy in endurance-trained (ET, n = 31) and untrained (n = 17) subjects. MBF and myocardial hypertrophy were studied using positron emission tomography and echocardiography, respectively. Both V˙O2peak (P < 0.001) and left ventricular (LV) mass index (P < 0.001) were higher in the ET group. Basal MBF was similar between the groups. MBF during adenosine was significantly lower in the ET group (2.88 ± 1.01 vs 3.64 ± 1.11 mL·g·min, P < 0.05) but not when the difference in LV mass was taken into account. V˙O2peak correlated negatively with adenosine-stimulated MBF, but when LV mass was taken into account as a partial correlate, this correlation disappeared. The present results show that increased LV mass in ET subjects explains the reduced hyperemic myocardial perfusion in this subject population and suggests that excessive LV hypertrophy has negative effect on cardiac blood flow capacity.

  3. FMLP provokes coronary vasoconstriction and myocardial ischemia in rabbits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gillespie, M.N.; Booth, D.C.; Friedman, B.J.

    Recent pathological studies of coronary arteries from humans with suspected coronary spasm have revealed an augmented intramural burden of inflammatory cells. To test the hypothesis than inappropriate activation of inflammatory cells participates in the evolution of coronary vasospasm, the present experiment employed a newly developed coronary arteriographic technique for use in pentobarbital-anesthetized rabbits to evaluate the coronary vasomotor actions of the nonselective inflammatory cell stimulant, N-formyl-L-methionyl-L-leucyl-L-phenylalanine (fMLP). In 10 of 10 animals, selective left intracoronary injection of 200 ng fMLP evoked profound left coronary narrowing accompanied in all cases by ST segment deviation and dysrhythmias. Thallium-201 scintigraphy demonstrated hypoperfusion ofmore » the left ventricular free wall and septum supplied by the spastic coronary artery. The fMLP-induced epicardial vasoconstriction, ischemic electrocardiogram (ECG) changes, and thallium perfusion defects were reversed by intravenous nitroglycerin. Neither the right coronary artery nor its distribution were influenced by left coronary injection of fMLP. Additional experiments in isolated, salt solution-perfused rabbit hearts demonstrated that fMLP failed to exert direct coronary vasoconstrictor effects. These observations indicate that the nonselective inflammatory cell stimulant, fMLP, provokes arteriographically demonstrable coronary spasm with attendant myocardial hypoperfusion and ischemic ECG changes in anesthetized rabbits. Such a model may be useful in exploring the dynamic role of inflammatory cells in development of coronary spasm.« less

  4. Minimal role of nitric oxide in basal coronary flow regulation and cardiac energetics of blood-perfused isolated canine heart.

    PubMed Central

    Saeki, A; Recchia, F A; Senzaki, H; Kass, D A

    1996-01-01

    1. The role of nitric oxide (NO) in the regulation of basal coronary perfusion and ventricular chamber energetics was studied in isovolumetrically contracting isolated blood-perfused canine hearts. Hearts were cross-perfused by a donor animal prior to isolation, and chamber volume controlled by a servo-pump. Coronary sinus flow and arterial-coronary sinus oxygen difference were measured to determine energetic efficiency. 2. NO synthase (NOS) was competitively inhibited by NG-monomethyl-L-arginine (L-NMMA; 0.5 mg kg-1, intracoronary), resulting in a reduction of acetylcholine (50 micrograms min-1)-induced flow augmentation from 143 to 62% (P < 0.001). 3. NOS inhibition had no significant effect on basal coronary flow. Coronary pressure-flow relationships were determined at a constant cardiac workload by varying mean perfusion pressure between 20 and 150 mmHg. Neither the shape of the relationship, nor the low-pressure value at which flow regulation was substantially diminished were altered by NOS inhibition. 4. Myocardial efficiency was assessed by the relationship between myocardial oxygen consumption and total pressure-volume area (PVA), with cavity volume altered to generate varying PVAs. This relative load-independent measure of energetic efficiency was minimally altered by NOS inhibition. 5. These results contrast with isolated crystalloid-perfused heart experiments and suggest that in hearts with highly controlled ventricular loading and whole-blood perfusion, effects of basal NO production on coronary perfusion and left ventricular energetics are minimal. PMID:8866868

  5. Magnetic resonance imaging (MRI) for the assessment of myocardial viability: an evidence-based analysis.

    PubMed

    2010-01-01

    diagnostic accuracy of echocardiographic assessment of myocardial viability. Intravenous contrast agents, which are high molecular weight inert gas microbubbles that act like red blood cells in the vascular space, can be used during echocardiography to assess myocardial viability. These agents allow for the assessment of myocardial blood flow (perfusion) and contractile function (as described above), as well as the simultaneous assessment of perfusion to make it possible to distinguish between stunned and hibernating myocardium. SPECT: SPECT can be performed using thallium-201 (Tl-201), a potassium analogue, or technetium-99 m labelled tracers. When Tl-201 is injected intravenously into a patient, it is taken up by the myocardial cells through regional perfusion, and Tl-201 is retained in the cell due to sodium/potassium ATPase pumps in the myocyte membrane. The stress-redistribution-reinjection protocol involves three sets of images. The first two image sets (taken immediately after stress and then three to four hours after stress) identify perfusion defects that may represent scar tissue or viable tissue that is severely hypoperfused. The third set of images is taken a few minutes after the re-injection of Tl-201 and after the second set of images is completed. These re-injection images identify viable tissue if the defects exhibit significant fill-in (> 10% increase in tracer uptake) on the re-injection images. The other common Tl-201 viability imaging protocol, rest-redistribution, involves SPECT imaging performed at rest five minutes after Tl-201 is injected and again three to four hours later. Viable tissue is identified if the delayed images exhibit significant fill-in of defects identified in the initial scans (> 10% increase in uptake) or if defects are fixed but the tracer activity is greater than 50%. There are two technetium-99 m tracers: sestamibi (MIBI) and tetrofosmin. The uptake and retention of these tracers is dependent on regional perfusion and the

  6. Impaired global myocardial flow dynamics despite normal left ventricular function and regional perfusion in chronic kidney disease: a quantitative analysis of clinical 82Rb PET/CT studies.

    PubMed

    Fukushima, Kenji; Javadi, Mehrbod S; Higuchi, Takahiro; Bravo, Paco E; Chien, David; Lautamäki, Riikka; Merrill, Jennifer; Nekolla, Stephan G; Bengel, Frank M

    2012-06-01

    Impaired global myocardial flow reserve (MFR) may be associated with increased risk for cardiac events and coronary artery disease progression. Chronic kidney disease (CKD) is also considered a risk factor for cardiovascular disease. We sought to investigate the effect of CKD on the myocardial microcirculation in patients referred for clinical (82)Rb PET/CT, who had normal left ventricular (LV) function and no flow-limiting coronary artery disease. Estimated glomerular filtration rate (eGFR) was available for 230 patients who had undergone rest and pharmacologic stress (82)Rb PET/CT for suspected coronary artery disease. CKD was defined as an eGFR less than 60 mL/min/1.73 m(2). After patients with hemodialysis, a renal transplant, abnormal regional perfusion (summed stress score > 4), or reduced LV function (LV ejection fraction < 45%) were excluded, 40 CKD patients remained. Those were compared with a control group without CKD, which was matched for age, sex, coronary risk factors, and systemic hemodynamics (n = 42). List-mode acquisition of PET enabled quantification of myocardial blood flow (MBF) and MFR using a previously validated retention model with correction for (82)Rb extraction. Rest MBF was normalized to rate-pressure product. Mean eGFR in the CKD group was reduced (44 ± 14 vs. 99 ± 28 mL/min/1.73 m(2); P < 0.0001), and creatinine was significantly elevated, compared with controls (1.9 ± 1.1 vs. 0.8 ± 0.2 mg/dL; P < 0.0001). MFR was significantly reduced in CKD (2.2 ± 1.0 vs. 3.0 ± 1.2 for controls; P = 0.027). This reduction was mainly due to increased rest MBF (1.1 ± 0.4 in CKD vs. 0.8 ± 0.2 mL/min/g in controls; P = 0.007). Stress myocardial flow was comparable between both groups (2.3 ± 0.9 vs. 2.3 ± 0.8 mL/min/g; P = 0.08). Overall, MFR was significantly correlated with eGFR (r = 0.41; P = 0.0005). Stress MBF did not correlate with eGFR (r = 0.002; P = 0.45), but rest MBF showed an inverse correlation (r = -0.49; P < 0.0001). Rest MBF was

  7. "Metabolically healthy" obesity: Prevalence, clinical features and association with myocardial ischaemia.

    PubMed

    De Lorenzo, Andrea; Glerian, Leticia; Amaral, Ana Carolina; Reis, Thiago B; Lima, Ronaldo S L

    To evaluate the prevalence of the "metabolically healthy" (MH) or "metabolically unhealthy" (MU) obesity phenotypes and their association with cardiorespiratory fitness and inducible myocardial ischaemia. Individuals without known coronary artery disease undergoing myocardial perfusion single-photon emission computed tomography (MPS) were studied. Those without dyslipidemia, hypertension, or diabetes were considered MH, and when ≥1 of these was present, MU status was considered present. Summed stress and difference perfusion scores (SSS and SDS, respectively) were calculated; a SDS >1 defined ischaemic MPS. MH patients were 35.0% of the nonobese population and 23.5% of the obese (p<0.001). The prevalence of ischaemia was not significantly different between MH patients with obesity or MH patients without obesity (10.9% vs 9.1%, p=0.3), except for patients with body mass index ≥40kg/m 2 (21.9%). MH obese patients were less frequently able to exercise and had lower exercise capacity than the nonobese patients. The prevalence of myocardial ischaemia was not significantly different between MH obese or nonobese individuals, supporting the concept of the "metabolically healthy obesity". However, there are other factors involved, such as the ability to exercise, that influence the risk of myocardial ischaemia, limiting the "safety" of that obesity phenotype. Copyright © 2016 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  8. Myocardial Gene Expression of T-bet, GATA-3, Ror-γt, FoxP3, and Hallmark Cytokines in Chronic Chagas Disease Cardiomyopathy: An Essentially Unopposed TH1-Type Response

    PubMed Central

    Nogueira, Luciana Gabriel; Santos, Ronaldo Honorato Barros; Fiorelli, Alfredo Inácio; Mairena, Eliane Conti; Benvenuti, Luiz Alberto; Bocchi, Edimar Alcides; Stolf, Noedir Antonio; Kalil, Jorge; Cunha-Neto, Edecio

    2014-01-01

    Background. Chronic Chagas disease cardiomyopathy (CCC), a late consequence of Trypanosoma cruzi infection, is an inflammatory cardiomyopathy with prognosis worse than those of noninflammatory etiology (NIC). Although the T cell-rich myocarditis is known to play a pathogenetic role, the relative contribution of each of the functional T cell subsets has never been thoroughly investigated. We therefore assessed gene expression of cytokines and transcription factors involved in differentiation and effector function of each functional T cell subset (TH1/TH2/TH17/Treg) in CCC, NIC, and heart donor myocardial samples. Methods and Results. Quantitative PCR showed markedly upregulated expression of IFN-γ and transcription factor T-bet, and minor increases of GATA-3; FoxP3 and CTLA-4; IL-17 and IL-18 in CCC as compared with NIC samples. Conversely, cytokines expressed by TH2 cells (IL-4, IL-5, and IL-13) or associated with Treg (TGF-β and IL-10) were not upregulated in CCC myocardium. Expression of TH1-related genes such as T-bet, IFN-γ, and IL-18 correlated with ventricular dilation, FoxP3, and CTLA-4. Conclusions. Results are consistent with a strong local TH1-mediated response in most samples, possibly associated with pathological myocardial remodeling, and a proportionally smaller FoxP3+CTLA4+ Treg cell population, which is unable to completely curb IFN-γ production in CCC myocardium, therefore fueling inflammation. PMID:25152568

  9. Quantitative evaluation improves specificity of myocardial perfusion SPECT in the assessment of functionally significant intermediate coronary artery stenoses: a comparative study with fractional flow reserve measurements.

    PubMed

    Sahiner, Ilgin; Akdemir, Umit O; Kocaman, Sinan A; Sahinarslan, Asife; Timurkaynak, Timur; Unlu, Mustafa

    2013-02-01

    Myocardial perfusion SPECT (MPS) is a noninvasive method commonly used for assessment of the hemodynamic significance of intermediate coronary stenoses. Fractional flow reserve (FFR) measurement is a well-validated invasive method used for the evaluation of intermediate stenoses. We aimed to determine the association between MPS and FFR findings in intermediate degree stenoses and evaluate the added value of quantification in MPS. Fifty-eight patients who underwent intracoronary pressure measurement in the catheterization laboratory to assess the physiological significance of intermediate (40-70%) left anterior descending (LAD) artery lesions, and who also underwent stress myocardial perfusion SPECT either for the assessment of an intermediate stenosis or for suspected coronary artery disease were analyzed retrospectively in the study. Quantitative analysis was performed using the 4DMSPECT program, with visual assessment performed by two experienced nuclear medicine physicians blinded to the angiographic findings. Summed stress scores (SSS) and summed difference scores (SDS) in the LAD artery territory according to the 20 segment model were calculated. A summed stress score of ≥ 3 and an SDS of ≥ 2 were assumed as pathologic, indicating significance of the lesion; a cutoff value of 0.75 was used to define abnormal FFR. Both visual and quantitative assessment results were compared with FFR using Chi-square (χ²) test. The mean time interval between two studies was 13 ± 11 days. FFR was normal in 45 and abnormal in 13 patients. Considering the FFR results as the gold standard method for assessing the significance of the lesion, the sensitivity and specificity of quantitative analysis determining the abnormal flow reserve were 85 and 84%, respectively, while visual analysis had a sensitivity of 77% and a specificity of 51%. There was a good agreement between the observers (κ = 0.856). Summed stress and difference scores demonstrated moderate inverse

  10. Circadian rhythms in myocardial metabolism and contractile function: influence of workload and oleate.

    PubMed

    Durgan, David J; Moore, Michael W S; Ha, Ngan P; Egbejimi, Oluwaseun; Fields, Anna; Mbawuike, Uchenna; Egbejimi, Anu; Shaw, Chad A; Bray, Molly S; Nannegari, Vijayalakshmi; Hickson-Bick, Diane L; Heird, William C; Dyck, Jason R B; Chandler, Margaret P; Young, Martin E

    2007-10-01

    Multiple extracardiac stimuli, such as workload and circulating nutrients (e.g., fatty acids), known to influence myocardial metabolism and contractile function exhibit marked circadian rhythms. The aim of the present study was to investigate whether the rat heart exhibits circadian rhythms in its responsiveness to changes in workload and/or fatty acid (oleate) availability. Thus, hearts were isolated from male Wistar rats (housed during a 12:12-h light-dark cycle: lights on at 9 AM) at 9 AM, 3 PM, 9 PM, and 3 AM and perfused in the working mode ex vivo with 5 mM glucose plus either 0.4 or 0.8 mM oleate. Following 20-min perfusion at normal workload (i.e., 100 cm H(2)O afterload), hearts were challenged with increased workload (140 cm H(2)O afterload plus 1 microM epinephrine). In the presence of 0.4 mM oleate, myocardial metabolism exhibited a marked circadian rhythm, with decreased rates of glucose oxidation, increased rates of lactate release, decreased glycogenolysis capacity, and increased channeling of oleate into nonoxidative pathways during the light phase. Rat hearts also exhibited a modest circadian rhythm in responsiveness to the workload challenge when perfused in the presence of 0.4 mM oleate, with increased myocardial oxygen consumption at the dark-to-light phase transition. However, rat hearts perfused in the presence of 0.8 mM oleate exhibited a markedly blunted contractile function response to the workload challenge during the light phase. In conclusion, these studies expose marked circadian rhythmicities in myocardial oxidative and nonoxidative metabolism as well as responsiveness of the rat heart to changes in workload and fatty acid availability.

  11. Acute insulin resistance in ST-segment elevation myocardial infarction in non-diabetic patients is associated with incomplete myocardial reperfusion and impaired coronary microcirculatory function

    PubMed Central

    2014-01-01

    Background Insulin resistance (IR) assessed by the Homeostatic Model Assessment (HOMA) index in the acute phase of myocardial infarction in non-diabetic patients was recently established as an independent predictor of intrahospital mortality. In this study we postulated that acute IR is a dynamic phenomenon associated with the development of myocardial and microvascular injury and larger final infarct size in patients with ST-segment elevation myocardial infarction (STEMI) treated by primary percutaneous coronary intervention (pPCI). Methods In 104 consecutive patients with the first anterior STEMI without diabetes, the HOMA index was determined on the 2nd and 7th day after pPCI. Worst-lead residual ST-segment elevation (ST-E) on postprocedural ECG, coronary flow reserve (CFR) determined by transthoracic Doppler echocardiography on the 2nd day after pPCI and fixed perfusion defect on single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) determined six weeks after pPCI were analyzed according to HOMA indices. Results IR was present in 55 % and 58 % of patients on day 2 and day 7, respectively. Incomplete post-procedural ST-E resolution was more frequent in patients with IR compared to patients without IR, both on day 2 (p = 0.001) and day 7 (p < 0.001). The HOMA index on day 7 correlated with SPECT-MPI perfusion defect (r = 0.331), whereas both HOMA indices correlated well with CFR (r = -0.331 to -0.386) (p < 0.01 for all). In multivariable backward logistic regression analysis adjusted for significant univariate predictors and potential confounding variables, IR on day 2 was an independent predictor of residual ST-E ≥ 2 mm (OR 11.70, 95% CI 2.46-55.51, p = 0.002) and CFR < 2 (OR = 5.98, 95% CI 1.88-19.03, p = 0.002), whereas IR on day 7 was an independent predictor of SPECT-MPI perfusion defect > 20% (OR 11.37, 95% CI 1.34-96.21, p = 0.026). Conclusion IR assessed by the HOMA index during the

  12. Nasal vaccination with troponin reduces troponin specific T-cell responses and improves heart function in myocardial ischemia–reperfusion injury

    PubMed Central

    Frenkel, Dan; Pachori, Alok S.; Zhang, Lunan; Dembinsky-Vaknin, Adi; Farfara, Dorit; Petrovic-Stojkovic, Sanja; Dzau, Victor J.

    2009-01-01

    Myocardial ischemia with subsequent reperfusion (MI/R) can lead to significant myocardial damage. Ischemia initiates inflammation at the blood–microvascular endothelial cell interface and contributes significantly to both acute injury and repair of the damaged tissue. We have found that MI/R injury in mice is associated with a cellular immune response to troponin. Myocardial cells exclusively synthesize troponin and release the troponin into the bloodstream following injury. Mucosally administered proteins induce T cells that secrete anti-inflammatory cytokines such as IL-10 and transforming growth factor β at the anatomical site where the protein localizes. We found that nasal administration of the three subunits of troponin (C, I and T isoforms), given prior to or 1 h following MI/R, decreased infarct size by 40% measured 24 h later. At 1.5 months following MI/R, there was a 50% reduction in infarct size and improvement in cardiac function as measured by echocardiography. Protection was associated with a reduction of cellular immunity to troponin. Immunohistochemistry demonstrated increased IL-10 and reduced IFN-γ in the area surrounding the ischemic infarct following nasal troponin. Adoptive transfer of CD4+ T cells to mice from nasally troponin-treated mice 1 h after the MI/R decreased infarct size by 72%, whereas CD4+ T cells from IL-10−/− mice or nasally BSA-treated mice had no effect. Our results demonstrate that IL-10-secreting CD4+ T cells induced by nasal troponin reduce injury following MI/R. Modulation of cardiac inflammation by nasal troponin provides a novel treatment to decrease myocardial damage and enhance recovery after myocardial ischemia. PMID:19515797

  13. Transient myocardial tissue and function changes during a marathon in less fit marathon runners.

    PubMed

    Gaudreault, Valerie; Tizon-Marcos, Helena; Poirier, Paul; Pibarot, Philippe; Gilbert, Philippe; Amyot, Marc; Rodés-Cabau, Josep; Després, Jean-Pierre; Bertrand, Olivier; Larose, Eric

    2013-10-01

    Although regular physical activity improves health, strenuous exercise might transiently increase cardiac risk. Training and fitness might provide protection. We prospectively studied 20 recreational marathon runners without known cardiovascular disease or symptoms: at peak training before, immediately after, and 3 months after a 42.2-km marathon. Changes in global/segmental myocardial function, edema, resting perfusion, and fibrosis were measured. At peak training, runners exercised 8.1 ± 2.3 hours and 62 ± 18 km per week with mean maximal oxygen consumption (VO2max) of 53.2 ± 8.3 mL/kg/min. In response to the marathon, global left ventricular and right ventricular ejection fraction decreased in half of the runners; these runners had poorer peak training distance, training time, and fitness level. Change in global left ventricular ejection fraction was associated with VO2max. Overall, 36% of segments developed edema, 53% decreased function, and 59% decreased perfusion. Significant agreement was observed between segment decreasing function, decreasing perfusion, and developing edema. Myocardial changes were reversible at 3 months. Completing a marathon leads to localized myocardial edema, diminished perfusion, and decreased function occurring more extensively in less trained and fit runners. Although reversible, these changes might contribute to the transient increase in cardiac risk reported during sustained vigorous exercise. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  14. Positron Emission Tomography for the Assessment of Myocardial Viability

    PubMed Central

    2010-01-01

    , harmonic imaging, and power doppler imaging may help to improve the diagnostic accuracy of echocardiographic assessment of myocardial viability. Stress Echocardiography with Contrast Intravenous contrast agents, which are high molecular weight inert gas microbubbles that act like red blood cells in the vascular space, can be used during echocardiography to assess myocardial viability. These agents allow for the assessment of myocardial blood flow (perfusion) and contractile function (as described above), as well as the simultaneous assessment of perfusion to make it possible to distinguish between stunned and hibernating myocardium. SPECT SPECT can be performed using thallium-201 (Tl-201), a potassium analogue, or technetium-99 m labelled tracers. When Tl-201 is injected intravenously into a patient, it is taken up by the myocardial cells through regional perfusion, and Tl-201 is retained in the cell due to sodium/potassium ATPase pumps in the myocyte membrane. The stress-redistribution-reinjection protocol involves three sets of images. The first two image sets (taken immediately after stress and then three to four hours after stress) identify perfusion defects that may represent scar tissue or viable tissue that is severely hypoperfused. The third set of images is taken a few minutes after the re-injection of Tl-201 and after the second set of images is completed. These re-injection images identify viable tissue if the defects exhibit significant fill-in (> 10% increase in tracer uptake) on the re-injection images. The other common Tl-201 viability imaging protocol, rest-redistribution, involves SPECT imaging performed at rest five minutes after Tl-201 is injected and again three to four hours later. Viable tissue is identified if the delayed images exhibit significant fill-in of defects identified in the initial scans (> 10% increase in uptake) or if defects are fixed but the tracer activity is greater than 50%. There are two technetium-99 m tracers: sestamibi (MIBI

  15. Protective effect of sevoflurane on myocardial ischemia-reperfusion injury in rat hearts and its impact on HIF-1α and caspase-3 expression.

    PubMed

    Zhou, Tao; Guo, Shanliang; Wang, Shaolin; Li, Qiong; Zhang, Mingsheng

    2017-11-01

    This study was designed to investigate possible protective effects of sevoflurane on myocardial ischemia-reperfusion injury (MIRI) and its impact on expression of HIF-1α and caspase-3 in rats, so as to provide new insights for the treatment of MIRI. Forty SD rats were randomly divided into four groups (n=10) including Sham operation (Sham), ischemia-reperfusion (IR), sevoflurane preconditioning group (Sevo-Pre) and sevoflurane post-conditioning (Sevo-Post) groups. Perfusion was performed using ex vivo heart perfusion. The baseline values of cardiac function were recorded in each group at the end of balanced perfusion and after 60 min of reperfusion. Myocardial infarct size (MIS) was calculated at the end of perfusion using TTC staining. Levels of HIF-1α and caspase-3 protein and HIF-1α (western blotting) and Bcl-2 mRNA (RT-qPCR) were detected at the end of reperfusion. Our results showed no significant differences in cardiac function between the groups at the end of the balanced perfusion. After reperfusion for 60 min, however, the cardiac functions of the Sevo-Pre and Sevo-Post groups were significantly better than those in the IR group, and the MIS at the end of reperfusion was significantly decreased. Western blotting and RT-qPCR showed that expression of HIF-1α protein was significantly increased, expression of caspase-3 protein was significantly decreased and expression of HIF-1α and Bcl-2 mRNA were significantly increased in Sevo-Pre and Sevo-Post groups compared with the levels in the IR group at the end of reperfusion. There were no significant differences in experimental results between Sevo-Pre and Sevo-Post groups. Our data support the idea that sevoflurane can improve MIRI in rats by improving cardiac function and reducing MIS. This protective effect seems to be achieved by activation of HIF-1α and inhibition of caspase-3.

  16. Effect of Outflow Tract Contributions to 82Rb-PET Global Myocardial Blood Flow Computations.

    PubMed

    Van Tosh, Andrew; Reichek, Nathaniel; Palestro, Christopher J; Nichols, Kenneth J

    2016-06-01

    Algorithms are able to compute myocardial blood flow (MBF) from dynamic PET data for each of the 17 left ventricular segments, with global MBF obtained by averaging segmental values. This study was undertaken to compare MBFs with and without the basal-septal segments. Data were examined retrospectively for 196 patients who underwent rest and regadenoson-stress (82)Rb PET/CT scanning for evaluation of known or suspected coronary artery disease. MBF data were acquired in gated list mode and rebinned to isolate the first-pass dynamic portion. Coronary vascular resistance (CVR) was computed as mean arterial pressure divided by MBF. MBF inhomogeneity was computed as the ratio of SD to mean MBF. Relative perfusion scores were obtained using (82)Rb-specific normal limits applied to polar maps of myocardial perfusion generated from myocardial equilibrium portions of PET data. MBF and CVRs from 17 and 14 segments were compared. Mean MBFs were lower for 17- than 14-segment means for rest (0.78 ± 0.50 vs. 0.85 ± 0.54 mL/g/min, paired t test P < 0.0001) and stress (1.50 ± 0.88 vs. 1.67 ± 0.96 mL/g/min, P < 0.0001). Bland-Altman plots of MBF differences versus means exhibited nonzero intercept (-0.04 ± 0.01, P = 0.0004) and significant correlation (r = -0.64, P < 0.0001), with slopes significantly different from 0.0 (-7.2% ± 0.6% and -8.3% ± 0.7% for rest and stress MBF; P < 0.0001). Seventeen-segment CVRs were higher than 14-segment CVRs for rest (159 ± 86 vs. 147 ± 81 mm Hg/mL/g/min, paired t test P < 0.0001) and stress CVR (85 ± 52 vs. 76 ± 48 mm Hg/mL/g/min, P < 0.0001). MBF inhomogeneity correlated significantly (P < 0.0001) with summed perfusion scores, but values correlated significantly more strongly for 14- than 17-segment values for rest (r = 0.67 vs. r = 0.52, P = 0.02) and stress (r = 0.69 vs. r = 0.47, P = 0.001). When basal segments were included in MBF determinations, perfusion inhomogeneity was greater both for rest (39% ± 10% vs. 31% ± 10%, P < 0

  17. 20 CFR 201.1 - Words and phrases.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Words and phrases. 201.1 Section 201.1 Employees' Benefits RAILROAD RETIREMENT BOARD REGULATIONS UNDER THE RAILROAD RETIREMENT ACT DEFINITIONS... as defined in the act and part 220 of this chapter. (e) Compensation. The term “compensation” means...

  18. Creation of an ensemble of simulated cardiac cases and a human observer study: tools for the development of numerical observers for SPECT myocardial perfusion imaging

    NASA Astrophysics Data System (ADS)

    O'Connor, J. Michael; Pretorius, P. Hendrik; Gifford, Howard C.; Licho, Robert; Joffe, Samuel; McGuiness, Matthew; Mehurg, Shannon; Zacharias, Michael; Brankov, Jovan G.

    2012-02-01

    Our previous Single Photon Emission Computed Tomography (SPECT) myocardial perfusion imaging (MPI) research explored the utility of numerical observers. We recently created two hundred and eighty simulated SPECT cardiac cases using Dynamic MCAT (DMCAT) and SIMIND Monte Carlo tools. All simulated cases were then processed with two reconstruction methods: iterative ordered subset expectation maximization (OSEM) and filtered back-projection (FBP). Observer study sets were assembled for both OSEM and FBP methods. Five physicians performed an observer study on one hundred and seventy-nine images from the simulated cases. The observer task was to indicate detection of any myocardial perfusion defect using the American Society of Nuclear Cardiology (ASNC) 17-segment cardiac model and the ASNC five-scale rating guidelines. Human observer Receiver Operating Characteristic (ROC) studies established the guidelines for the subsequent evaluation of numerical model observer (NO) performance. Several NOs were formulated and their performance was compared with the human observer performance. One type of NO was based on evaluation of a cardiac polar map that had been pre-processed using a gradient-magnitude watershed segmentation algorithm. The second type of NO was also based on analysis of a cardiac polar map but with use of a priori calculated average image derived from an ensemble of normal cases.

  19. Transient giant negative T wave in acute anterior myocardial infarction predicts R wave recovery and preservation of left ventricular function.

    PubMed Central

    Agetsuma, H.; Hirai, M.; Hirayama, H.; Suzuki, A.; Takanaka, C.; Yabe, S.; Inagaki, H.; Takatsu, F.; Hayashi, H.; Saito, H.

    1996-01-01

    OBJECTIVE: To investigate the value of a giant negative T wave (> or = 1.0 mV) in precordial leads of 12-lead electrocardiograms in the acute phase of Q wave myocardial infarction as a predictor of myocardial salvage. METHODS: Coronary angiographic and electrocardiographic findings, left ventricular ejection fraction in the chronic stage, and levels of cardiac enzymes were compared in patients with myocardial infarction with (group GNT, n = 31) and without (group N, n = 20) a giant negative T wave. GNT patients were divided into two subgroups according to the presence (GNT:R[+], n = 10) or absence (GNT: R[-], n = 21) of R wave recovery with an amplitude > or = 0.1 mV in at least one lead that had shown Q waves. RESULTS: The maximum level of creatine kinase and the total creatine kinase were lower in group GNT compared with group N (P < 0.05). The left ventricular ejection fraction was higher in group GNT than in group N (P < 0.05). The maximum creatine kinase and total creatine kinase were lower in GNT:R(+) than in GNT:R(-) (P < 0.01). The left ventricular ejection fraction was higher in GNT:R(+) than in GNT:R(-) (P < 0.01). The frequency of R wave recovery was significantly higher when giant negative T waves appeared within 100 h of myocardial infarction or when the maximum potential was > or = 1.4 mV. The appearance of a giant negative T wave > or = 1.4 mV had a sensitivity of 90%, a specificity of 71.4%, a diagnostic accuracy of 77.4%, a positive predictive value of 60%, and a negative predictive value of 93.8% for prediction of R wave recovery. CONCLUSIONS: The appearance of a giant negative T wave, especially within 100 h of the onset of myocardial infarction, with a maximum potential of > or = 1.4 mV, may predict a reappearance of the R wave and a better left ventricular function in patients in the chronic stage of anterior myocardial infarction. PMID:8800983

  20. Dose reduction assessment in dynamic CT myocardial perfusion imaging in a porcine balloon-induced-ischemia model

    NASA Astrophysics Data System (ADS)

    Fahmi, Rachid; Eck, Brendan L.; Vembar, Mani; Bezerra, Hiram G.; Wilson, David L.

    2014-03-01

    We investigated the use of an advanced hybrid iterative reconstruction (IR) technique (iDose4, Philips Health- care) for low dose dynamic myocardial CT perfusion (CTP) imaging. A porcine model was created to mimic coronary stenosis through partial occlusion of the left anterior descending (LAD) artery with a balloon catheter. The severity of LAD occlusion was adjusted with FFR measurements. Dynamic CT images were acquired at end-systole (45% R-R) using a multi-detector CT (MDCT) scanner. Various corrections were applied to the acquired scans to reduce motion and imaging artifacts. Absolute myocardial blood flow (MBF) was computed with a deconvolution-based approach using singular value decomposition (SVD). We compared a high and a low dose radiation protocol corresponding to two different tube-voltage/tube-current combinations (80kV p/100mAs and 120kV p/150mAs). The corresponding radiation doses for these protocols are 7.8mSv and 34.3mSV , respectively. The images were reconstructed using conventional FBP and three noise-reduction strengths of the IR method, iDose. Flow contrast-to-noise ratio, CNRf, as obtained from MBF maps, was used to quantitatively evaluate the effect of reconstruction on contrast between normal and ischemic myocardial tissue. Preliminary results showed that the use of iDose to reconstruct low dose images provide better or comparable CNRf to that of high dose images reconstructed with FBP, suggesting significant dose savings. CNRf was improved with the three used levels of iDose compared to FBP for both protocols. When using the entire 4D dynamic sequence for MBF computation, a 77% dose reduction was achieved, while considering only half the scans (i.e., every other heart cycle) allowed even further dose reduction while maintaining relatively higher CNRf.

  1. Regional myocardial oxygen tension: 19F MRI of sequestered perfluorocarbon.

    PubMed

    Shukla, H P; Mason, R P; Bansal, N; Antich, P P

    1996-06-01

    A novel noninvasive method of measuring local myocardial oxygen tension (pO2) in the perfused rat heart using 19F MRI is demonstrated. Tissue pO2 was determined on the basis of the 19F spin-lattice relaxation rate (R1) of perflubron (perfluorooctyl bromide) sequestered in the heart after IV infusion of an emulsion. Spectroscopic measurement of R1 was previously used to measure a global weighted average of oxygen status. 19F MRI now provides 3D spatial resolution indicating local cardiac pO2 under normally perfused, globally ischemic, and regionally ischemic conditions.

  2. Experimental Study of the Effects of EIPA, Losartan, and BQ-123 on Electrophysiological Changes Induced by Myocardial Stretch.

    PubMed

    Chorro, Francisco J; Canto, Irene Del; Brines, Laia; Such-Miquel, Luis; Calvo, Conrado; Soler, Carlos; Zarzoso, Manuel; Trapero, Isabel; Tormos, Álvaro; Such, Luis

    2015-12-01

    Mechanical response to myocardial stretch has been explained by various mechanisms, which include Na(+)/H(+) exchanger activation by autocrine-paracrine system activity. Drug-induced changes were analyzed to investigate the role of these mechanisms in the electrophysiological responses to acute myocardial stretch. Multiple epicardial electrodes and mapping techniques were used to analyze changes in ventricular fibrillation induced by acute myocardial stretch in isolated perfused rabbit hearts. Four series were studied: control (n = 9); during perfusion with the angiotensin receptor blocker losartan (1 μM, n = 8); during perfusion with the endothelin A receptor blocker BQ-123 (0.1 μM, n = 9), and during perfusion with the Na(+)/H(+) exchanger inhibitor EIPA (5-[N-ethyl-N-isopropyl]-amiloride) (1 μM, n = 9). EIPA attenuated the increase in the dominant frequency of stretch-induced fibrillation (control=40.4%; losartan=36% [not significant]; BQ-123=46% [not significant]; and EIPA=22% [P<.001]). During stretch, the activation maps were less complex (P<.0001) and the spectral concentration of the arrhythmia was greater (greater regularity) in the EIPA series: control=18 (3%); EIPA = 26 (9%) (P < .02); losartan=18 (5%) (not significant); and BQ-123=18 (4%) (not significant). The Na(+)/H(+) exchanger inhibitor EIPA attenuated the electrophysiological effects responsible for the acceleration and increased complexity of ventricular fibrillation induced by acute myocardial stretch. The angiotensin II receptor antagonist losartan and the endothelin A receptor blocker BQ-123 did not modify these effects. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  3. Stress myocardial perfusion imaging in the emergency department--new techniques for speed and diagnostic accuracy.

    PubMed

    Harrison, Sheri D; Harrison, Mark A; Duvall, W Lane

    2012-05-01

    Emergency room evaluations of patients presenting with chest pain continue to rise, and these evaluations which often include cardiac imaging, are an increasing area of resource utilization in the current health system. Myocardial perfusion imaging from the emergency department remains a vital component of the diagnosis or exclusion of coronary artery disease as the etiology of chest pain. Recent advances in camera technology, and changes to the imaging protocols have allowed MPI to become a more efficient way of providing this diagnostic information. Compared with conventional SPECT, new high-efficiency CZT cameras provide a 3-5 fold increase in photon sensitivity, 1.65-fold improvement in energy resolution and a 1.7-2.5-fold increase in spatial resolution. With stress-only imaging, rest images are eliminated if stress images are normal, as they provide no additional prognostic or diagnostic value and cancelling the rest images would shorten the length of the test which is of particular importance to the ED population. The rapid but accurate triage of patients in an ED CPU is essential to their care, and stress-only imaging and new CZT cameras allow for shorter test time, lower radiation doses and lower costs while demonstrating good clinical outcomes. These changes to nuclear stress testing can allow for faster throughput of patients through the emergency department while providing a safe and efficient evaluation of chest pain.

  4. 9 CFR 201.1 - Meaning of words.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Meaning of words. 201.1 Section 201.1 Animals and Animal Products GRAIN INSPECTION, PACKERS AND STOCKYARDS ADMINISTRATION (PACKERS AND... plural, and vice versa, as the case may demand. [19 FR 4524, July 22, 1954] ...

  5. Biological characterization of F-18-labeled rhodamine B, a potential positron emission tomography perfusion tracer.

    PubMed

    Bartholomä, Mark D; He, Huamei; Pacak, Christina A; Dunning, Patricia; Fahey, Frederic H; McGowan, Francis X; Cowan, Douglas B; Treves, S Ted; Packard, Alan B

    2013-11-01

    Myocardial infarction is the leading cause of death in western countries, and positron emission tomography (PET) plays an increasing role in the diagnosis and treatment planning for this disease. However, the absence of an (18)F-labeled PET myocardial perfusion tracer hampers the widespread use of PET in myocardial perfusion imaging (MPI). We recently reported a potential MPI agent based on (18)F-labeled rhodamine B. The goal of this study was to more completely define the biological properties of (18)F-labeled rhodamine B with respect to uptake and localization in an animal model of myocardial infarction and to evaluate the uptake (18)F-labeled rhodamine B by cardiomyocytes. A total of 12 female Sprague Dawley rats with a permanent ligation of the left anterior descending artery (LAD) were studied with small-animal PET. The animals were injected with 100-150 μCi of (18)F-labeled rhodamine B diethylene glycol ester ([(18)F]RhoBDEGF) and imaged two days before ligation. The animals were imaged again two to ten days post-ligation. After the post-surgery scans, the animals were euthanized and the hearts were sectioned into 1mm slices and myocardial infarct size was determined by phosphorimaging and 2,3,5-triphenyltetrazolium chloride staining (TTC). In addition, the uptake of [(18)F]RhoBDEGF in isolated rat neonatal cardiomyocytes was determined by fluorescence microscopy. Small-animal PET showed intense and uniform uptake of [(18)F]RhoBDEGF throughout the myocardium in healthy rats. After LAD ligation, well defined perfusion defects were observed in the PET images. The defect size was highly correlated with the infarct size as determined ex vivo by phosphorimaging and TTC staining. In vitro, [(18)F]RhoBDEGF was rapidly internalized into rat cardiomyocytes with ~40 % of the initial activity internalized within the 60 min incubation time. Fluorescence microscopy clearly demonstrated localization of [(18)F]RhoBDEGF in the mitochondria of rat cardiomyocytes. Fluorine-18

  6. Biological Characterization of F-18-Labeled Rhodamine B, a Potential Positron Emission Tomography Perfusion Tracer

    PubMed Central

    Bartholomä, Mark D.; He, Huamei; Pacak, Christina; Dunning, Patricia; Fahey, Frederic H.; McGowan, Francis; Cowan, Douglas; Treves, S. Ted; Packard, Alan B.

    2013-01-01

    Introduction Myocardial infarction is the leading cause of death in western countries, and positron emission tomography (PET) plays an increasing role in the diagnosis and treatment planning for this disease. However, the absence of an F-18-labeled PET myocardial perfusion tracer hampers the widespread use of PET in myocardial perfusion imaging (MPI). We recently reported a potential MPI agent based on F-18-labeled rhodamine B. The goal of this study was to more completely define the biological properties of F-18-labeled rhodamine B with respect to uptake and localization in an animal model of myocardial infarction and to evaluate the uptake F-18-labeled rhodamine B by cardiomyocytes. Methods A total of 12 female Sprague Dawley rats with a permanent ligation of the left anterior descending artery (LAD) were studied with small-animal PET. The animals were injected with 100–150 µCi of F-18-labeled rhodamine B diethylene glycol ester ([18F]RhoBDEGF) and imaged two days before ligation. The animals were imaged again two to ten days post-ligation. After the post-surgery scans, the animals were euthanized and the hearts were sectioned into 1 mm slices and myocardial infarct size was determined by phosphorimaging and 2,3,5-triphenyltetrazolium chloride staining (TTC). In addition, the uptake of [18F]RhoBDEGF in isolated rat neonatal cardiomyocytes was determined by fluorescence microscopy. Results Small-animal PET showed intense and uniform uptake of [18F]RhoBDEGF throughout the myocardium in healthy rats. After LAD ligation, well defined perfusion defects were observed in the PET images. The defect size was highly correlated with the infarct size as determined ex vivo by phosphorimaging and TTC staining. In vitro, [18F]RhoBDEGF was rapidly internalized into rat cardiomyocytes with ~40 % of the initial activity internalized within the 60 min incubation time. Fluorescence microscopy clearly demonstrated localization of [18F]RhoBDEGF in the mitochondria of rat

  7. Increase in electrocardiographic R-waves after revascularization in patients with acute myocardial infarction.

    PubMed

    Isobe, Satoshi; Takada, Yasuo; Ando, Akitada; Ohshima, Satoru; Yamada, Kiyoyasu; Nanasato, Mamoru; Unno, Kazumasa; Ogawa, Takuo; Kondo, Takahisa; Izawa, Hideo; Inden, Yasuya; Hirai, Makoto; Murohara, Toyoaki

    2006-11-01

    The physiological mechanism of the increase in the electrocardiographic (ECG) R-wave voltage after revascularization in patients with acute myocardial infarction (MI) needs to be elucidated. One hundred and thirty-eight MI patients (83: anterior MI, 45: inferior MI, 10: lateral MI) underwent ECG and echocardiography in both the acute and subacute phases after emergency revascularization, as well as a resting thallium-201/iodine-123 15-p-iodophenyl-3-(R,S)-methyl pentadecanoic acid myocardial scintigraphy in the acute phase. The total sum of the R-wave voltage (SigmaR) was calculated over multiple leads on ECG for each infarcted lesion. Scintigraphic defect on each tracer was expressed as the percentage (%) defect of the total left ventricular (LV) myocardium. The % defect-discordance on both images in the acute phase and the % increase in SigmaR and the absolute increase in LV ejection fraction from the acute to the subacute phase (DeltaEF) were also calculated. The SigmaR in the subacute phase was significantly greater than that in the acute phase (p<0.0001). The % increase in SigmaR significantly correlated with the DeltaEF (r=0.57, p<0.0001). The % increase in SigmaR also correlated with the % defect-discordance (r=0.68, p<0.0001). The increase in the ECG R-wave voltage reflects not only the improvement in myocardial perfusion but also the presence of salvaged myocardium after revascularization in acute MI patients.

  8. CD8+CD28+ T cells might mediate injury of cardiomyocytes in acute myocardial infarction.

    PubMed

    Zhang, Lili; Wang, Zhiyan; Wang, Di; Zhu, Jumo; Wang, Yi

    2018-06-07

    CD8 + T cells accumulate in the necrotic myocardium of acute myocardial infarction (AMI). It is unclear whether CD8 + CD28 + T cells, a specific subset of CD8 + T cells, contribute to myocardial injury. In this study, 92 consecutive patients with AMI and 28 healthy control subjects were enrolled. The frequency of CD8 + CD28 + T cells in peripheral blood samples was assayed by flow cytometry. Plasma cardiac troponin I (TNI) and left ventricular ejection fraction (LVEF) were determined. Long-term prognosis of the patients was evaluated by major adverse cardiac and cerebrovascular events (MACCE) over a 12-month follow-up period. Our findings indicated that patients with AMI who presented with high numbers of CD8 + CD28 + T cells had an increased infarction size and aggravated ventricular function. We proposed that cytotoxic CD8 + CD28 + T cell-mediated myocardial necrosis may act as a novel and alternative pathway of AMI. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. 38 CFR 20.1 - Rule 1. Purpose and construction of Rules of Practice.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Rule 1. Purpose and construction of Rules of Practice. 20.1 Section 20.1 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) BOARD OF VETERANS' APPEALS: RULES OF PRACTICE General § 20.1 Rule 1. Purpose...

  10. 38 CFR 20.1 - Rule 1. Purpose and construction of Rules of Practice.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Rule 1. Purpose and construction of Rules of Practice. 20.1 Section 20.1 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) BOARD OF VETERANS' APPEALS: RULES OF PRACTICE General § 20.1 Rule 1. Purpose...

  11. Exercise testing and thallium-201 myocardial perfusion scintigraphy in the clinical evaluation of patients with Wolff Parkinson White syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poyatos, M.E.; Suarez, L.; Lerman, J.

    1986-10-01

    In 58 patients with Wolff Parkinson White syndrome (WPW), we performed exercise stress testing in order to investigate the incidence of normalization of the auriculo-ventricular conduction and the ST-segment changes. For a more accurate evaluation of the latter, exercise and redistribution radionuclide images with Thallium-201 were obtained in 18 cases. Forty-nine had type A and nine had type B of WPW. Forty-eight had permanent, four had alternant and six had no pre-excitation (PE) when they started the test. Mean maximal functional capacity, mean maximal heart rate and mean maximal double product were not different when compared to an age-matched controlmore » group. Of the 48 patients who began the test with PE, in 23 (48%) it disappeared while PE persisted in 25 (52%). In 16 cases the disappearance of the PE was sudden and in seven it was progressive. Pre-excitation persisted in 39.5% of patients with type A and in 88.8% with type B (p less than 0.01). ST-segment depression was observed in 76.6% of patients with PE and in 28.6% of cases without PE (p less than 0.01). ST-segment depression occurred in 44.8% of patients with type A and in 100% of cases with type B (p less than 0.05). Transient abnormal Thallium-201 scans were observed in 62.5% of patients without PE and in 20% with PE. No patients showed exertional arrhythmias. This study suggests the possibility of measuring the duration of the refractory period of the accessory pathway in those patients n which the PE disappears suddenly, at a given heart rate.« less

  12. Gender differences in the diagnostic accuracy of SPECT myocardial perfusion imaging: a bivariate meta-analysis.

    PubMed

    Iskandar, Aline; Limone, Brendan; Parker, Matthew W; Perugini, Andrew; Kim, Hyejin; Jones, Charles; Calamari, Brian; Coleman, Craig I; Heller, Gary V

    2013-02-01

    It remains controversial whether the diagnostic accuracy of single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) is different in men as compared to women. We performed a meta-analysis to investigate gender differences of SPECT MPI for the diagnosis of CAD (≥50% stenosis). Two investigators independently performed a systematic review of the MEDLINE and EMBASE databases from inception through January 2012 for English-language studies determining the diagnostic accuracy of SPECT MPI. We included prospective studies that compared SPECT MPI with conventional coronary angiography which provided sufficient data to calculate gender-specific true and false positives and negatives. Data from studies evaluating <20 patients of one gender were excluded. Bivariate meta-analysis was used to create summary receiver operating curves. Twenty-six studies met inclusion criteria, representing 1,148 women and 1,142 men. Bivariate meta-analysis yielded a mean sensitivity and specificity of 84.2% (95% confidence interval [CI] 78.7%-88.6%) and 78.7% (CI 70.0%-85.3%) for SPECT MPI in women and 89.1% (CI 84.0%-92.7%) and 71.2% (CI 60.8%-79.8%) for SPECT MPI in men. There was no significant difference in the sensitivity (P = .15) or specificity (P = .23) between male and female subjects. In a bivariate meta-analysis of the available literature, the diagnostic accuracy of SPECT MPI is similar for both men and women.

  13. Different Causes of Death in Patients with Myocardial Infarction Type 1, Type 2, and Myocardial Injury.

    PubMed

    Lambrecht, Sascha; Sarkisian, Laura; Saaby, Lotte; Poulsen, Tina S; Gerke, Oke; Hosbond, Susanne; Diederichsen, Axel C P; Thygesen, Kristian; Mickley, Hans

    2018-05-01

    Data outlining the mortality and the causes of death in patients with type 1 myocardial infarction, type 2 myocardial infarction, and those with myocardial injury are limited. During a 1-year period from January 2010 to January 2011, all hospitalized patients who had cardiac troponin I measured on clinical indication were prospectively studied. Patients with at least one cardiac troponin I value >30 ng/L underwent case ascertainment and individual evaluation by an experienced adjudication committee. Patients were classified as having type 1 myocardial infarction, type 2 myocardial infarction, or myocardial injury according to the criteria of the universal definition of myocardial infarction. Follow-up was ensured until December 31, 2014. Data on mortality and causes of death were obtained from the Danish Civil Registration System and the Danish Register of Causes of Death. Overall, 3762 consecutive patients were followed for a mean of 3.2 years (interquartile range 1.3-3.6 years). All-cause mortality differed significantly among categories: Type 1 myocardial infarction 31.7%, type 2 myocardial infarction 62.2%, myocardial injury 58.7%, and 22.2% in patients with nonelevated troponin values (log-rank test; P < .0001). In patients with type 1 myocardial infarction, 61.3% died from cardiovascular causes, vs 42.6% in patients with type 2 myocardial infarction (P = .015) and 41.2% in those with myocardial injury (P < .0001). The overall mortality and the causes of death did not differ substantially between patients with type 2 myocardial infarction and those with myocardial injury. Patients with type 2 myocardial infarction and myocardial injury exhibit a significantly higher long-term mortality compared with patients with type 1 myocardial infarction . However, most patients with type 1 myocardial infarction die from cardiovascular causes in contrast to patients with type 2 myocardial infarction and myocardial injury, in whom noncardiovascular causes of death

  14. Australian and New Zealand Perfusion Survey: Management and Procedure

    PubMed Central

    Tuble, Sigrid C.; Willcox, Timothy W.; Baker, Robert A.

    2009-01-01

    Abstract: In this report, we will discuss management and procedural aspects of perfusion practice. This report allows us to compare and contrast recent trends and changes in perfusion with historic practices. A survey comprised of 233 single-answer and 12 open-ended questions was sent by e-mail to senior perfusionists or individuals in charge of perfusion in 40 hospital groups. The survey encompasses a review of the perfusion practices for the calendar year of 2003, and respondents were required to answer the survey based on the predominant practice in their institutions. Standard management of routine adult cardiopulmonary bypass (CPB) in 2003 consisted of perfusion strategies that achieved a target temperature of 32.0°C (range, 28.0–35.0°C), a flow index of 2.4 L/min/m2 (range, 1.6–3.0 L/min/m2) during normothermia and 1.8 L/min/m2 (range, 1.2–3.0 L/min/m2) during hypothermia, and a pressure during CPB between 50 (range, 30–65 mmHg) and 70 mmHg (range, 60–95 mmHg). Myocardial protection with blood cardioplegia was used in 77% of the 20,688 CPB cases, whereas in 53% cases, cardiotomy blood was never processed. Pre-operatively, 76% of perfusion groups assessed their patients (21% directly with the patient), and 85% responded that perfusionists performed or participated in a formal pre-bypass checklist. The majority of the perfusion groups used a handwritten perfusion record (62%), 12% used an electronic perfusion record, and 26% used both, whereas more than one half of the groups were involved in quality assurance (79%), incident reporting (74%), audits (62%), research (53%), participating in interdisciplinary meetings (53%), and morbidity and mortality meetings (65%). Only 26% conducted formal perfusion team meetings. This report outlines the status of clinical management and procedural performance for perfusion practices in Australia and New Zealand in 2003. Awareness of these trends will allow perfusionists to assess both individual practices and

  15. State of the Art: Clinical Applications of Cardiac T1 Mapping.

    PubMed

    Schelbert, Erik B; Messroghli, Daniel R

    2016-03-01

    While cardiovascular magnetic resonance (MR) has become the noninvasive tool of choice for the assessment of myocardial viability and for the detection of acute myocardial edema, cardiac T1 mapping is believed to further extend the ability of cardiovascular MR to characterize the myocardium. Fundamentally, cardiovascular MR can improve diagnosis of disease that historically has been challenging to establish with other imaging modalities. For example, decreased native T1 values appear highly specific to detect and quantify disease severity related to myocardial iron overload states or glycosphingolipid accumulation in Anderson-Fabry disease, whereas high native T1 values are observed with edema, amyloid, and other conditions. Cardiovascular MR can also improve the assessment of prognosis with parameters that relate to myocardial structure and composition that complement the familiar functional parameters around which contemporary cardiology decision making revolves. In large cohorts, extracellular volume fraction (ECV) has been shown to quantify the full extent of myocardial fibrosis in noninfarcted myocardium. ECV may predict outcomes at least as effectively as left ventricular ejection fraction. This uncommon statistical observation (of potentially being more strongly associated with outcomes than ejection fraction) suggests prime biologic importance for the cardiac interstitium that may rank highly in the hierarchy of vast myocardial changes occurring in cardiac pathophysiology. This article presents current and developing clinical applications of cardiac T1 mapping and reviews the existing evidence on their diagnostic and prognostic value in various clinical conditions. This article also contextualizes these advances and explores how T1 mapping and ECV may affect major "global" issues such as diagnosis of disease, risk stratification, and paradigms of disease, and ultimately how we conceptualize patient vulnerability.

  16. High Concordance Between Mental Stress-Induced and Adenosine-Induced Myocardial Ischemia Assessed Using SPECT in Heart Failure Patients: Hemodynamic and Biomarker Correlates.

    PubMed

    Wawrzyniak, Andrew J; Dilsizian, Vasken; Krantz, David S; Harris, Kristie M; Smith, Mark F; Shankovich, Anthony; Whittaker, Kerry S; Rodriguez, Gabriel A; Gottdiener, John; Li, Shuying; Kop, Willem; Gottlieb, Stephen S

    2015-10-01

    Mental stress can trigger myocardial ischemia, but the prevalence of mental stress-induced ischemia in congestive heart failure (CHF) patients is unknown. We characterized mental stress-induced and adenosine-induced changes in myocardial perfusion and neurohormonal activation in CHF patients with reduced left-ventricular function using SPECT to precisely quantify segment-level myocardial perfusion. Thirty-four coronary artery disease patients (mean age±SD, 62±10 y) with CHF longer than 3 mo and ejection fraction less than 40% underwent both adenosine and mental stress myocardial perfusion SPECT on consecutive days. Mental stress consisted of anger recall (anger-provoking speech) followed by subtraction of serial sevens. The presence and extent of myocardial ischemia was quantified using the conventional 17-segment model. Sixty-eight percent of patients had 1 ischemic segment or more during mental stress and 81% during adenosine. On segment-by-segment analysis, perfusion with mental stress and adenosine were highly correlated. No significant differences were found between any 2 time points for B-type natriuretic peptide, tumor necrosis factor-α, IL-1b, troponin, vascular endothelin growth factor, IL-17a, matrix metallopeptidase-9, or C-reactive protein. However, endothelin-1 and IL-6 increased, and IL-10 decreased, between the stressor and 30 min after stress. Left-ventricular end diastolic dimension was 179±65 mL at rest and increased to 217±71 after mental stress and 229±86 after adenosine (P<0.01 for both). Resting end systolic volume was 129±60 mL at rest and increased to 158±66 after mental stress (P<0.05) and 171±87 after adenosine (P<0.07), with no significant differences between adenosine and mental stress. Ejection fraction was 30±12 at baseline, 29±11 with mental stress, and 28±10 with adenosine (P=not significant). There was high concordance between ischemic perfusion defects induced by adenosine and mental stress, suggesting that mental

  17. Magnetic Resonance Imaging (MRI) for the Assessment of Myocardial Viability

    PubMed Central

    2010-01-01

    techniques including echocardiography using contrast agents, harmonic imaging, and power doppler imaging may help to improve the diagnostic accuracy of echocardiographic assessment of myocardial viability. Stress Echocardiography with Contrast Intravenous contrast agents, which are high molecular weight inert gas microbubbles that act like red blood cells in the vascular space, can be used during echocardiography to assess myocardial viability. These agents allow for the assessment of myocardial blood flow (perfusion) and contractile function (as described above), as well as the simultaneous assessment of perfusion to make it possible to distinguish between stunned and hibernating myocardium. SPECT SPECT can be performed using thallium-201 (Tl-201), a potassium analogue, or technetium-99 m labelled tracers. When Tl-201 is injected intravenously into a patient, it is taken up by the myocardial cells through regional perfusion, and Tl-201 is retained in the cell due to sodium/potassium ATPase pumps in the myocyte membrane. The stress-redistribution-reinjection protocol involves three sets of images. The first two image sets (taken immediately after stress and then three to four hours after stress) identify perfusion defects that may represent scar tissue or viable tissue that is severely hypoperfused. The third set of images is taken a few minutes after the re-injection of Tl-201 and after the second set of images is completed. These re-injection images identify viable tissue if the defects exhibit significant fill-in (> 10% increase in tracer uptake) on the re-injection images. The other common Tl-201 viability imaging protocol, rest-redistribution, involves SPECT imaging performed at rest five minutes after Tl-201 is injected and again three to four hours later. Viable tissue is identified if the delayed images exhibit significant fill-in of defects identified in the initial scans (> 10% increase in uptake) or if defects are fixed but the tracer activity is greater than 50

  18. Automatic 3D registration of dynamic stress and rest (82)Rb and flurpiridaz F 18 myocardial perfusion PET data for patient motion detection and correction.

    PubMed

    Woo, Jonghye; Tamarappoo, Balaji; Dey, Damini; Nakazato, Ryo; Le Meunier, Ludovic; Ramesh, Amit; Lazewatsky, Joel; Germano, Guido; Berman, Daniel S; Slomka, Piotr J

    2011-11-01

    The authors aimed to develop an image-based registration scheme to detect and correct patient motion in stress and rest cardiac positron emission tomography (PET)/CT images. The patient motion correction was of primary interest and the effects of patient motion with the use of flurpiridaz F 18 and (82)Rb were demonstrated. The authors evaluated stress/rest PET myocardial perfusion imaging datasets in 30 patients (60 datasets in total, 21 male and 9 female) using a new perfusion agent (flurpiridaz F 18) (n = 16) and (82)Rb (n = 14), acquired on a Siemens Biograph-64 scanner in list mode. Stress and rest images were reconstructed into 4 ((82)Rb) or 10 (flurpiridaz F 18) dynamic frames (60 s each) using standard reconstruction (2D attenuation weighted ordered subsets expectation maximization). Patient motion correction was achieved by an image-based registration scheme optimizing a cost function using modified normalized cross-correlation that combined global and local features. For comparison, visual scoring of motion was performed on the scale of 0 to 2 (no motion, moderate motion, and large motion) by two experienced observers. The proposed registration technique had a 93% success rate in removing left ventricular motion, as visually assessed. The maximum detected motion extent for stress and rest were 5.2 mm and 4.9 mm for flurpiridaz F 18 perfusion and 3.0 mm and 4.3 mm for (82)Rb perfusion studies, respectively. Motion extent (maximum frame-to-frame displacement) obtained for stress and rest were (2.2 ± 1.1, 1.4 ± 0.7, 1.9 ± 1.3) mm and (2.0 ± 1.1, 1.2 ±0 .9, 1.9 ± 0.9) mm for flurpiridaz F 18 perfusion studies and (1.9 ± 0.7, 0.7 ± 0.6, 1.3 ± 0.6) mm and (2.0 ± 0.9, 0.6 ± 0.4, 1.2 ± 1.2) mm for (82)Rb perfusion studies, respectively. A visually detectable patient motion threshold was established to be ≥2.2 mm, corresponding to visual user scores of 1 and 2. After motion correction, the average

  19. Short intra-aortic balloon pump in a swine model of myocardial ischaemia: a proof-of-concept study.

    PubMed

    Gelsomino, Sandro; Lozekoot, Pieter W J; Lorusso, Roberto; de Jong, Monique M J; Parise, Orlando; Matteucci, Francesco; Lucà, Fabiana; La Meir, Mark; Gensini, Gian Franco; Maessen, Jos G

    2016-03-01

    This proof-of-concept study examined the haemodynamic performance as well as the coronary and visceral organ perfusion using a new short balloon for intra-aortic counterpulsation (IABP) in a swine model of myocardial ischaemia. Eighteen healthy pigs underwent 120-min ligation of the left anterior descending coronary artery followed by 6 h of reperfusion, and they were randomly assigned into 3 groups undergoing IABP implantation with a 35-ml short balloon (n = 6), a 40-ml short balloon (n = 6) or no IABP implantation (controls, n = 6). Haemodynamics, and visceral and coronary flows were measured at baseline (t0), at 2 h of ischaemia (t1) and every hour thereafter until 6 h of reperfusion (from tR1 to tR6), respectively. Mesenteric and renal flows increased significantly at tR1 only in the IABP groups (all, P < 0.001) and were significantly higher than controls throughout the reperfusion periods (P < 0.001). Coronary systolic and diastolic blood flows increased only at tR1 in the IABP groups (all, P < 0.001) but were higher than controls at tR1-tR6. The IABP was associated with enhanced haemodynamics compared with controls. No difference was detected using different balloon volumes (all, P > 0.05). The new short balloon significantly increased visceral flow, enhanced haemodynamics and improved coronary circulation during reperfusion following myocardial ischaemia in our experimental model. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Cardiovascular Magnetic Resonance Imaging of Myocardial Infarction, Viability, and Cardiomyopathies

    PubMed Central

    West, Amy M.; Kramer, Christopher M.

    2010-01-01

    Cardiovascular magnetic resonance provides the opportunity for a truly comprehensive evaluation of patients with a history of MI, with regards to characterizing the extent of disease, impact on LV function and degree of viable myocardium. The use of contrast-enhanced CMR for first-pass perfusion and late gadolinium enhancement is a powerful technique for delineating areas of myocardial ischemia and infarction. Using a combination of T2-weighted and contrast-enhanced CMR images, information about the acuity of an infarct can be obtained. There is an extensive amount of literature using contrast-enhanced CMR to predict myocardial functional recovery with revascularization in patients with ischemic cardiomyopathies. In addition, CMR imaging in patients with cardiomyopathies can distinguish between ischemic and non-ischemic etiologies, with the ability to further characterize the underlying pathology for non-ischemic cardiomyopathies. PMID:20197150