Sample records for tables reference materials

  1. 40 CFR 92.5 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...: (1) ASTM material. The following table sets forth material from the American Society for Testing and...., Philadelphia, PA 19103. The table follows: Document number and name 40 CFR part 92 reference ASTM D 86-95, Standard Test Method for Distillation of Petroleum Products § 92.113 ASTM D 93-94, Standard Test Methods...

  2. Fast mix table construction for material discretization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, S. R.

    2013-07-01

    An effective hybrid Monte Carlo-deterministic implementation typically requires the approximation of a continuous geometry description with a discretized piecewise-constant material field. The inherent geometry discretization error can be reduced somewhat by using material mixing, where multiple materials inside a discrete mesh voxel are homogenized. Material mixing requires the construction of a 'mix table,' which stores the volume fractions in every mixture so that multiple voxels with similar compositions can reference the same mixture. Mix table construction is a potentially expensive serial operation for large problems with many materials and voxels. We formulate an efficient algorithm to construct a sparse mixmore » table in O(number of voxels x log number of mixtures) time. The new algorithm is implemented in ADVANTG and used to discretize continuous geometries onto a structured Cartesian grid. When applied to an end-of-life MCNP model of the High Flux Isotope Reactor with 270 distinct materials, the new method improves the material mixing time by a factor of 100 compared to a naive mix table implementation. (authors)« less

  3. Fast Mix Table Construction for Material Discretization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Seth R

    2013-01-01

    An effective hybrid Monte Carlo--deterministic implementation typically requires the approximation of a continuous geometry description with a discretized piecewise-constant material field. The inherent geometry discretization error can be reduced somewhat by using material mixing, where multiple materials inside a discrete mesh voxel are homogenized. Material mixing requires the construction of a ``mix table,'' which stores the volume fractions in every mixture so that multiple voxels with similar compositions can reference the same mixture. Mix table construction is a potentially expensive serial operation for large problems with many materials and voxels. We formulate an efficient algorithm to construct a sparse mix table inmore » $$O(\\text{number of voxels}\\times \\log \\text{number of mixtures})$$ time. The new algorithm is implemented in ADVANTG and used to discretize continuous geometries onto a structured Cartesian grid. When applied to an end-of-life MCNP model of the High Flux Isotope Reactor with 270 distinct materials, the new method improves the material mixing time by a factor of 100 compared to a naive mix table implementation.« less

  4. 40 CFR 1048.810 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....org. Table 1 follows: Table 1 of § 1048.810—SAE Materials Document number and name Part 1048reference..., Switzerland or http://www.iso.org. Table 2 follows: Table 2 of § 1048.810—ISO Materials Document number and...

  5. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (a) ASTM material. Table 1 to this section lists material from the American Society for Testing and..., West Conshohocken, PA 19428 or http://www.astm.com. Table 1 follows: Table 1 to § 1060.810—ASTM Materials Document number and name Part 1060reference ASTM D471-06, Standard Test Method for Rubber Property...

  6. 40 CFR 94.5 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .../code_of_federal_regulations/ibr_locations.html. (a) ASTM material. Table 1 of § 94.5 lists material... of § 94.5—ASTM Materials Document No. and name Part 94 reference ASTM D 86-01, Standard Test Method for Distillation of Petroleum Products at Atmospheric Pressure 94.108 ASTM D 93-02, Standard Test...

  7. 40 CFR 90.7 - Reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS General § 90.7 Reference materials... Fuels by the Research Method Appendix A to subpart D, Table 3. ASTM D2700-92: Standard Test Method for...

  8. 40 CFR 90.7 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS General § 90.7 Reference materials... Fuels by the Research Method Appendix A to subpart D, Table 3. ASTM D2700-92: Standard Test Method for...

  9. 40 CFR 90.7 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS General § 90.7 Reference materials... Fuels by the Research Method Appendix A to subpart D, Table 3. ASTM D2700-92: Standard Test Method for...

  10. 40 CFR 1045.810 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Definitions and Other Reference Information § 1045.810 What materials does this part reference? Documents... material. Table 1 to this section lists material from the Society of Automotive Engineers that we have... the Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096 or http://www.sae...

  11. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., July 26, 2004 1060.105, 1060.240 (d) American Boat and Yacht Council Material. Table 4 to this section lists material from the American Boat and Yacht Council that we have incorporated by reference. The... Yacht Council, 613 Third Street, Suite 10, Annapolis, MD 21403 or http://www.abycinc.org/. Table 4...

  12. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY... Speciation, December 2003 1060.801 (c) California Air Resources Board material. Table 3 to this section lists material from the California Air Resources Board that we have incorporated by reference. The first column...

  13. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY... Speciation, December 2003 1060.801 (c) California Air Resources Board material. Table 3 to this section lists material from the California Air Resources Board that we have incorporated by reference. The first column...

  14. 40 CFR 1060.810 - What materials does this part reference?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND STATIONARY... Speciation, December 2003 1060.801 (c) California Air Resources Board material. Table 3 to this section lists material from the California Air Resources Board that we have incorporated by reference. The first column...

  15. The AME2016 atomic mass evaluation (II). Tables, graphs and references

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Meng; Audi, G.; Kondev, F. G.

    This paper is the second part of the new evaluation of atomic masses, Ame2016. Using least-squares adjustments to all evaluated and accepted experimental data, described in Part I, we derive tables with numerical values and graphs to replace those given in Ame2012. The first table lists the recommended atomic mass values and their uncertainties. It is followed by a table of the influences of data on primary nuclides, a table of various reaction and decay energies, and finally, a series of graphs of separation and decay energies. The last section of this paper lists all references of the input datamore » used in the Ame2016 and the Nubase2016 evaluations (first paper in this issue). Amdc: http://amdc.impcas.ac.cn/« less

  16. 49 CFR 172.101 - Purpose and use of hazardous materials table.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Purpose and use of hazardous materials table. 172.101 Section 172.101 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS HAZARDOUS MATERIALS TABLE, SPECIAL PROVISIONS,...

  17. 49 CFR 172.101 - Purpose and use of hazardous materials table.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Purpose and use of hazardous materials table. 172.101 Section 172.101 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS HAZARDOUS MATERIALS TABLE, SPECIAL PROVISIONS,...

  18. 49 CFR 172.101 - Purpose and use of hazardous materials table.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Purpose and use of hazardous materials table. 172.101 Section 172.101 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS HAZARDOUS MATERIALS TABLE, SPECIAL PROVISIONS,...

  19. 78 FR 69310 - Hazardous Materials Table, Special Provisions, Hazardous Materials Communications, Emergency...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-19

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part 172 Hazardous Materials Table, Special Provisions, Hazardous Materials Communications, Emergency Response Information, Training Requirements, and Security Plans CFR Correction In Title 49 of the Code of...

  20. 14 CFR Appendix B to Part 382 - Cross-Reference Table

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Cross-Reference Table B Appendix B to Part 382 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) SPECIAL REGULATIONS NONDISCRIMINATION ON THE BASIS OF DISABILITY IN AIR TRAVEL Pt. 382, App. B Appendix B...

  1. 14 CFR Appendix B to Part 382 - Cross-Reference Table

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Cross-Reference Table B Appendix B to Part 382 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) SPECIAL REGULATIONS NONDISCRIMINATION ON THE BASIS OF DISABILITY IN AIR TRAVEL Pt. 382, App. B Appendix B...

  2. 9 CFR 354.247 - Table showing types of materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Table showing types of materials. 354.247 Section 354.247 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF... Sanitary Conditions and Precautions Against Contamination of Products § 354.247 Table showing types of...

  3. Investigation on Suitability of Natural Fibre as Replacement Material for Table Tennis Blade

    NASA Astrophysics Data System (ADS)

    Arifin, A. M. T.; Fahrul Hassan, M.; Ismail, A. E.; Zulafif Rahim, M.; Rasidi Ibrahim, M.; Haq, R. H. Abdul; Rahman, M. N. A.; Yunos, M. Z.; Amin, M. H. M.

    2017-08-01

    This paper presents an investigation of suitability natural fibre as replacement material for table tennis blade, due to low cost, lightweight and apparently environmentally. Nowadays, natural fibre are one of the materials often used in replaced the main material on manufacturing sector, such as automotive, and construction. The objective of this study is to investigate and evaluate the suitability natural fiber materials to replace wood as a structure on table tennis blade. The mechanical properties of the different natural fibre material were examined, and correlated with characteristic of table tennis blade. The natural fibre selected for the study are kenaf (Hibiscus Cannabinus), jute, hemp, sisal (Agave Sisalana) and ramie. A further comparison was made with the corresponding properties of each type of natural fiber using Quality Function Deployment (QFD) and Theory of Inventive Problem Solving (TRIZ). TRIZ has been used to determine the most appropriate solution in producing table tennis blade. The results showed the most appropriate solution in producing table tennis blade using natural fibre is kenaf natural fibre. The selected on suitability natural fibre used as main structure on table tennis blade are based on the characteristics need for good performance of table tennis blade, such as energy absorption, lightweight, strength and hardness. Therefore, it shows an opportunity for replacing existing materials with a higher strength, lower cost alternative that is environmentally friendly.

  4. USGS reference materials

    USGS Publications Warehouse

    ,

    1995-01-01

    Every year in the United States, millions of measurements are made on the chemical composition of items that affect us on a daily basis. Determining the accuracy of these measurements is based on the analysis of appropriate reference materials whose composition was previously determined through rigorous testing. Today, reference materials help us evaluate the composition of the food we eat, medicine we use, soil we grow our crops in, and hundreds of other products that affect our everyday lives.

  5. 40 CFR 94.5 - Reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., Washington, DC 20460 or at the National Archives and Records Administration (NARA). For information on the.../code_of_federal_regulations/ibr_locations.html. (a) ASTM material. Table 1 of § 94.5 lists material... internal combustion engines—Exhaust emission measurement—Part 1: Test-bed measurement of gaseous and...

  6. Composite slip table of dissimilar materials for damping longitudinal modes

    DOEpatents

    Gregory, Danny L.; Priddy, Tommy G.; Smallwood, David O.; Woodall, Tommy D.

    1991-01-01

    A vibration slip table for use in a vibration testing apparatus. The table s comprised of at least three composite layers of material; a first metal layer, a second damping layer, and a third layer having a high acoustic velocity relative to the first layer. The different acoustic velocities between the first and third layers cause relative shear displacements between the layers with the second layer damping the displacements between the first and third layers to reduce the table longitudinal vibration modes.

  7. Composite slip table of dissimilar materials for damping longitudinal modes

    DOEpatents

    Gregory, D.L.; Priddy, T.G.; Smallwood, D.O.; Woodall, T.D.

    1991-06-18

    A vibration slip table for use in a vibration testing apparatus is disclosed. The tables comprised of at least three composite layers of material; a first metal layer, a second damping layer, and a third layer having a high acoustic velocity relative to the first layer. The different acoustic velocities between the first and third layers cause relative shear displacements between the layers with the second layer damping the displacements between the first and third layers to reduce the table longitudinal vibration modes. 6 figures.

  8. 40 CFR 1043.100 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Reference materials. 1043.100 Section... § 1043.100 Reference materials. Documents listed in this section have been incorporated by reference into... the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  9. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Reference materials. 1042.910 Section... Other Reference Information § 1042.910 Reference materials. Documents listed in this section have been... information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  10. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Reference materials. 1042.910 Section... Other Reference Information § 1042.910 Reference materials. Documents listed in this section have been... information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov...

  11. Effect of Transitioning from Standard Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering

    DTIC Science & Technology

    2016-04-01

    Reference Material 2806b for Light Obscuration Particle Countering April 2016 UNCLASSIFIED UNCLASSIFIED Joel Schmitigal 27809 Standard Form 298 (Rev...Standard Reference Material 2806b for Light Obscuration Particle Countering 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering Joel Schmitigal Force Projection

  12. Certified reference materials and reference methods for nuclear safeguards and security.

    PubMed

    Jakopič, R; Sturm, M; Kraiem, M; Richter, S; Aregbe, Y

    2013-11-01

    Confidence in comparability and reliability of measurement results in nuclear material and environmental sample analysis are established via certified reference materials (CRMs), reference measurements, and inter-laboratory comparisons (ILCs). Increased needs for quality control tools in proliferation resistance, environmental sample analysis, development of measurement capabilities over the years and progress in modern analytical techniques are the main reasons for the development of new reference materials and reference methods for nuclear safeguards and security. The Institute for Reference Materials and Measurements (IRMM) prepares and certifices large quantities of the so-called "large-sized dried" (LSD) spikes for accurate measurement of the uranium and plutonium content in dissolved nuclear fuel solutions by isotope dilution mass spectrometry (IDMS) and also develops particle reference materials applied for the detection of nuclear signatures in environmental samples. IRMM is currently replacing some of its exhausted stocks of CRMs with new ones whose specifications are up-to-date and tailored for the demands of modern analytical techniques. Some of the existing materials will be re-measured to improve the uncertainties associated with their certified values, and to enable laboratories to reduce their combined measurement uncertainty. Safeguards involve the quantitative verification by independent measurements so that no nuclear material is diverted from its intended peaceful use. Safeguards authorities pay particular attention to plutonium and the uranium isotope (235)U, indicating the so-called 'enrichment', in nuclear material and in environmental samples. In addition to the verification of the major ratios, n((235)U)/n((238)U) and n((240)Pu)/n((239)Pu), the minor ratios of the less abundant uranium and plutonium isotopes contain valuable information about the origin and the 'history' of material used for commercial or possibly clandestine purposes, and

  13. A new thorium-229 reference material

    DOE PAGES

    Essex, Richard M.; Mann, Jaqueline L.; Williams, Ross W.; ...

    2017-07-27

    A new reference material was characterized for 229Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230Th)/n( 229Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232Th)/n( 229Th) ratio is (3.815 ± 0.092)×10 -4.

  14. A new thorium-229 reference material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Essex, Richard M.; Mann, Jaqueline L.; Williams, Ross W.

    A new reference material was characterized for 229Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230Th)/n( 229Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232Th)/n( 229Th) ratio is (3.815 ± 0.092)×10 -4.

  15. Bisphenol A polycarbonate as a reference material

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.; Williams, J. B.

    1977-01-01

    Test methods require reference materials to standardize and maintain quality control. Various materials have been evaluated as possible reference materials, including a sample of bisphenol A polycarbonate without additives. Screening tests for relative toxicity under various experimental conditions were performed using male mice exposed to pyrolysis effluents over a 200-800 C temperature range. It was found that the bisphenol A polycarbonate served as a suitable reference material as it is available in large quantities, and does not significantly change with time.

  16. Value assignment of nutrient concentrations in five standard reference materials and six reference materials.

    PubMed

    Sharpless, K E; Gill, L M

    2000-01-01

    A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of

  17. 40 CFR 1045.810 - What materials does this part reference?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... material. Table 1 to this section lists material from the Society of Automotive Engineers that we have... the Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096 or http://www.sae...

  18. 40 CFR 1045.810 - What materials does this part reference?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... material. Table 1 to this section lists material from the Society of Automotive Engineers that we have... the Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096 or http://www.sae...

  19. Isotope reference materials

    USGS Publications Warehouse

    Coplen, Tyler B.

    2010-01-01

    Measurement of the same isotopically homogeneous sample by any laboratory worldwide should yield the same isotopic composition within analytical uncertainty. International distribution of light element isotopic reference materials by the International Atomic Energy Agency and the U.S. National Institute of Standards and Technology enable laboratories to achieve this goal.

  20. 40 CFR 89.6 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... set forth the material that has been incorporated by reference in this part. (1) ASTM material. The... 19428-2959. Document number and name 40 CFR part 89 reference ASTM D86-97: “Standard Test Method for Distillation of Petroleum Products at Atmospheric Pressure” Appendix A to Subpart D. ASTM D93-97: “Standard...

  1. The use of reference materials in quality assurance programmes in food microbiology laboratories.

    PubMed

    In't Veld, P H

    1998-11-24

    Nine different reference materials (RMs) for use in food and water microbiology have been developed with the support of the European Commission (EC). The production process of RMs is based on spray drying bacteria suspended in milk. The highly contaminated milk powder (HCMP) obtained is mixed with sterile milk powder to achieve the desired level of contamination and is subsequently filled into gelatine capsules. The HCMP may need to be stabilised by storage for more than a year before a stable RM can be prepared. The HCMP are mixed with sterile milk powder using a pestle and mortar in order to produce homogeneous RMs. For routine use of RMs Shewhart control charts can be produced. Based on log10 transformed counts, control limits are calculated. Rules for the interpretation of results facilitate the detection of out of control situations. Besides RMs there are also CRMs (Certified Reference Materials) that are certified by the EC Community Bureau of Reference (BCR) and are intended for occasional use. Based on the BCR certificate, user tables are produced presenting the 95% confidence limits for the number of capsules likely to be examined in practice. Also power analysis is made to indicate the minimum difference between the certified value and the observed geometric mean value in relation to the number of capsules examined.

  2. Reference Materials: Significance, General Requirements, and Demand.

    PubMed

    Kiełbasa, Anna; Gadzała-Kopciuch, Renata; Buszewski, Bogusław

    2016-05-03

    Reference materials play an important part in the quality control of measurements. Rapid development of such new scientific disciplines as proteomics, metabolomics, and genomics also necessitates development of new reference materials. This is a great challenge due to the complexity of the production of new reference materials and difficulties associated with achieving their homogeneity and stability. CRMs of tissue are of particular importance. They can be counted among the matrices that are most complex and time consuming in preparation. Tissue is the place of transformation and accumulation of many substances (e.g., metabolites, which are intermediate or end products resulting from metabolic processes). Trace amounts of many substances in tissues must be determined with adequate precision and accuracy. To meet the needs stemming from research and from problems and challenges faced by chemists, analysts, and toxicologists, the number of certified reference materials should be continuously increased.

  3. Installation Torque Tables for Noncritical Applications

    NASA Technical Reports Server (NTRS)

    Rivera-Rosario, Hazel T.; Powell, Joseph S.

    2017-01-01

    The objective of this project is to define torque values for bolts and screws when loading is not a concern. Fasteners require a certain torque to fulfill its function and prevent failure. NASA Glenn Research Center did not have a set of fastener torque tables for non-critical applications without loads, usually referring to hand-tight or wrench-tight torqueing. The project is based on two formulas, torque and pullout load. Torque values are calculated giving way to preliminary data tables. Testing is done to various bolts and metal plates, torqueing them until the point of failure. Around 640 torque tables were developed for UNC, UNF, and M fasteners. Different lengths of thread engagement were analyzed for the 5 most common materials used at GRC. The tables were put together in an Excel spreadsheet and then formatted into a Word document. The plan is to later convert this to an official technical publication or memorandum.

  4. 40 CFR 1068.95 - What materials does this part reference?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... material. Table 1 to this section lists material from the Society of Automotive Engineers that we have... the Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096 or http://www.sae... SAE J1930, Electrical/Electronic Systems Diagnostic Terms, Definitions, Abbreviations, and Acronyms...

  5. 40 CFR 1068.95 - What materials does this part reference?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... material. Table 1 to this section lists material from the Society of Automotive Engineers that we have... the Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096 or http://www.sae... SAE J1930, Electrical/Electronic Systems Diagnostic Terms, Definitions, Abbreviations, and Acronyms...

  6. 40 CFR 1068.95 - What materials does this part reference?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... material. Table 1 to this section lists material from the Society of Automotive Engineers that we have... the Society of Automotive Engineers, 400 Commonwealth Drive, Warrendale, PA 15096 or http://www.sae... SAE J1930, Electrical/Electronic Systems Diagnostic Terms, Definitions, Abbreviations, and Acronyms...

  7. The importance of reference materials in doping-control analysis.

    PubMed

    Mackay, Lindsey G; Kazlauskas, Rymantas

    2011-08-01

    Currently a large range of pure substance reference materials are available for calibration of doping-control methods. These materials enable traceability to the International System of Units (SI) for the results generated by World Anti-Doping Agency (WADA)-accredited laboratories. Only a small number of prohibited substances have threshold limits for which quantification is highly important. For these analytes only the highest quality reference materials that are available should be used. Many prohibited substances have no threshold limits and reference materials provide essential identity confirmation. For these reference materials the correct identity is critical and the methods used to assess identity in these cases should be critically evaluated. There is still a lack of certified matrix reference materials to support many aspects of doping analysis. However, in key areas a range of urine matrix materials have been produced for substances with threshold limits, for example 19-norandrosterone and testosterone/epitestosterone (T/E) ratio. These matrix-certified reference materials (CRMs) are an excellent independent means of checking method recovery and bias and will typically be used in method validation and then regularly as quality-control checks. They can be particularly important in the analysis of samples close to threshold limits, in which measurement accuracy becomes critical. Some reference materials for isotope ratio mass spectrometry (IRMS) analysis are available and a matrix material certified for steroid delta values is currently under production. In other new areas, for example the Athlete Biological Passport, peptide hormone testing, designer steroids, and gene doping, reference material needs still need to be thoroughly assessed and prioritised.

  8. Reproducibility of polycarbonate reference material in toxicity evaluation

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Huttlinger, P. A.

    1981-01-01

    A specific lot of bisphenol A polycarbonate has been used for almost four years as the reference material for the NASA-USF-PSC toxicity screening test method. The reproducibility of the test results over this period of time indicate that certain plastics may be more suitable reference materials than the more traditional cellulosic materials.

  9. FLIS Procedures Manual Multiple Application References/Instructions/Tables and Grids.

    DTIC Science & Technology

    1996-10-01

    Agency OUSD ATIN: DCB/IIS Washington, DC 20505 62 Department of Health , Education, and Welfare Food and Drug Administration ATTN: Supply Requirements...Table 206 3 3 Table 209 1 thru 6 1 thru 6 Table 214 -- 1 thru 3 11. SIGNIFICANT CHANGES A. The page replacements are effective upon receipt. B... Effective Date (ED) Processing Conflict Conditions .......................................................................... 99 Effective Dated (ED

  10. STANDARD REFERENCE MATERIALS FOR THE POLYMERS INDUSTRY.

    PubMed

    McDonough, Walter G; Orski, Sara V; Guttman, Charles M; Migler, Kalman D; Beers, Kathryn L

    2016-01-01

    The National Institute of Standards and Technology (NIST) provides science, industry, and government with a central source of well-characterized materials certified for chemical composition or for some chemical or physical property. These materials are designated Standard Reference Materials ® (SRMs) and are used to calibrate measuring instruments, to evaluate methods and systems, or to produce scientific data that can be referred readily to a common base. In this paper, we discuss the history of polymer based SRMs, their current status, and challenges and opportunities to develop new standards to address industrial measurement challenges.

  11. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  12. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  13. 40 CFR 91.6 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... EMISSIONS FROM MARINE SPARK-IGNITION ENGINES General § 91.6 Reference materials. (a) Incorporation by... the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock... 40 CFR part 91 reference SAE J1228/ISO 8665 November 1991 Small Craft-Marine Propulsion Engine and...

  14. Some possible reference materials for fire toxicity tests

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Solis, A. N.

    1977-01-01

    Suitable reference materials need to be selected in order to standardize any test method. The evaluation of cotton, polyethylene, polyether sulfone, polycarbonate, polystyrene, and polyurethane flexible and rigid foams as possible reference materials for the University of San Francisco/NASA toxicity screening test method is discussed.

  15. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  16. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  17. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  18. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  19. 15 CFR 200.104 - Standard reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the NIST National Measurement Laboratory administers a program to provide many types of well... be readily referred to a common base. NIST SP 260 is a catalog of Standard Reference Materials available from NIST. ...

  20. 40 CFR 1068.95 - What materials does this part reference?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... material from the Society of Automotive Engineers that we have incorporated by reference. The first column... reference it. Anyone may purchase copies of these materials from the Society of Automotive Engineers, 400... Materials Document number and name Part 1068reference SAE J1930, Electrical/Electronic Systems Diagnostic...

  1. 40 CFR 1068.95 - What materials does this part reference?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... material from the Society of Automotive Engineers that we have incorporated by reference. The first column... reference it. Anyone may purchase copies of these materials from the Society of Automotive Engineers, 400... Materials Document number and name Part 1068reference SAE J1930, Electrical/Electronic Systems Diagnostic...

  2. 10 CFR 431.105 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Storage Tanks Test Procedures § 431.105 Materials incorporated by reference. (a) The Department... Water Supply Boilers, and Unfired Hot Water Storage Tanks,” Docket No. EE-RM/TP-99-480, Forrestal... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 431.105 Section 431...

  3. Studies, Summary Tables, and Data Related to the Advancing Sustainable Materials Management Report

    EPA Pesticide Factsheets

    This webpage provides further information about how EPA measures data for the annual Advancing Materials Management Report. Researchers can use the tables and studies to better understand how waste in managed in America

  4. Biological and environmental reference materials in CENAM.

    PubMed

    Arvizu-Torres, R; Perez-Castorena, A; Salas-Tellez, J A; Mitani-Nakanishi, Y

    2001-06-01

    Since 1994, when the NIST/NOAA Quality Assurance Program in Chemical Measurements was discussed in Queretaro, CENAM, the National Measurement Institute (NMI) of Mexico, has become involved in the development of reference materials. In the field of biological and environmental reference materials, in particular, the NORAMET collaboration program with NIST and NRC, and the North-American Environmental Cooperation signed among three free-trade treaty organizations, have greatly helped the development of the materials metrology program in the newly established CENAM. This paper describes some particularly significant efforts of CENAM in the development of biological and environmental reference materials, on the basis of inter-comparison studies organized with local and governmental environmental agencies of Mexico. In the field of water pollution CENAM has developed a practical proficiency testing (PT) scheme for field laboratories, as a part of registration by local government in the metropolitan area, according to the Mexican Ecological Regulation. The results from these eight PTs in the last 5 years have demonstrated that this scheme has helped ensure the reliability of analytical capability of more than 50 field laboratories in three states, Mexico, D.F., and the States of Mexico and Queretaro. Similar experience has been obtained for more than 70 service units of stack emission measurements in the three states in 1998 and 1999, as a result of the design of a PT scheme for reference gas mixtures. This PT scheme has been accomplished successfully by 30 analytical laboratories who provide monitoring services and perform research on toxic substances (Hg, methylmercury, PCB, etc.) in Mexico. To support these activities, reference samples have been produced through the NIST SRMs, and efforts have been made to increase CENAM's capability in the preparation of primary reference materials in spectrometric solutions and gas mixtures. Collaboration among NMIs has also

  5. Polyfluorinated substances in abiotic standard reference materials

    EPA Science Inventory

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, meth...

  6. Preparation of Reference Material 8504, Transformer Oil

    PubMed Central

    Poster, Dianne L.; Schantz, Michele M.; Wise, Stephen A.

    2005-01-01

    A new reference material (RM), RM 8504, has been prepared for use as a diluent oil with Aroclors in transformer oil Standard Reference Materials (SRMs) 3075 to 3080 and SRM 3090 when developing and validating methods for the determination of polychlorinated biphenyls (PCBs) as Aroclors in transformer oil or similar matrices. SRMs 3075-3080 and SRM 3090 consist of individual Aroclors in the same transformer oil that was used to prepare RM 8504. A unit of RM 8504 consists of one bottle containing approximately 100 mL of transformer oil. No additional constituents have been added to the oil. PMID:27308183

  7. Knowledge of childhood: materiality, text, and the history of science - an interdisciplinary round table discussion.

    PubMed

    Rietmann, Felix; Schildmann, Mareike; Arni, Caroline; Cook, Daniel Thomas; Giuriato, Davide; Göhlsdorf, Novina; Muigai, Wangui

    2017-03-01

    This round table discussion takes the diversity of discourse and practice shaping modern knowledge about childhood as an opportunity to engage with recent historiographical approaches in the history of science. It draws attention to symmetries and references among scientific, material, literary and artistic cultures and their respective forms of knowledge. The five participating scholars come from various fields in the humanities and social sciences and allude to historiographical and methodological questions through a range of examples. Topics include the emergence of children's rooms in US consumer magazines, research on the unborn in nineteenth-century sciences of development, the framing of autism in nascent child psychiatry, German literary discourses about the child's initiation into writing, and the sociopolitics of racial identity in the photographic depiction of African American infant corpses in the early twentieth century. Throughout the course of the paper, childhood emerges as a topic particularly amenable to interdisciplinary perspectives that take the history of science as part of a broader history of knowledge.

  8. delta 15N and non-carbonate delta 13C values for two petroleum source rock reference materials and a marine sediment reference material

    USGS Publications Warehouse

    Dennen, Kristin O.; Johnson, Craig A.; Otter, Marshall L.; Silva, Steven R.; Wandless, Gregory A.

    2006-01-01

    Samples of United States Geological Survey (USGS) Certified Reference Materials USGS Devonian Ohio Shale (SDO-1), and USGS Eocene Green River Shale (SGR-1), and National Research Council Canada (NRCC) Certified Marine Sediment Reference Material (PACS-2), were sent for analysis to four separate analytical laboratories as blind controls for organic rich sedimentary rock samples being analyzed from the Red Dog mine area in Alaska. The samples were analyzed for stable isotopes of carbon (delta13Cncc) and nitrogen (delta15N), percent non-carbonate carbon (Wt % Cncc) and percent nitrogen (Wt % N). SDO-1, collected from the Huron Member of the Ohio Shale, near Morehead, Kentucky, and SGR-1, collected from the Mahogany zone of the Green River Formation are petroleum source rocks used as reference materials for chemical analyses of sedimentary rocks. PACS-2 is modern marine sediment collected from the Esquimalt, British Columbia harbor. The results presented in this study are, with the exceptions noted below, the first published for these reference materials. There are published information values for the elemental concentrations of 'organic' carbon (Wt % Corg measured range is 8.98 - 10.4) and nitrogen (Wt % Ntot 0.347 with SD 0.043) only for SDO-1. The suggested values presented here should be considered 'information values' as defined by the NRCC Institute for National Measurement Reference Materials and should be useful for the analysis of 13C, 15N, C and N in organic material in sedimentary rocks.

  9. Reference Materials and Subject Matter Knowledge Codes for Airman Knowledge Testing

    DOT National Transportation Integrated Search

    2004-06-08

    The listings of reference materials and subject matter knowledge codes have been : prepared by the Federal Aviation Administration (FAA) to establish specific : references for all knowledge standards. The listings contain reference materials : to be ...

  10. Stream Tables and Watershed Geomorphology Education.

    ERIC Educational Resources Information Center

    Lillquist, Karl D.; Kinner, Patricia W.

    2002-01-01

    Reviews copious stream tables and provides a watershed approach to stream table exercises. Results suggest that this approach to learning the concepts of fluvial geomorphology is effective. (Contains 39 references.) (DDR)

  11. Recent developments in the field of environmental reference materials at the JRC Ispra.

    PubMed

    Muntau, H

    2001-06-01

    The production of reference materials for environmental analysis started in the Joint Research Centre at Ispra/Italy in 1972 with the objective of later certification by the BCR, but for obvious budget reasons only a fraction of the total production achieved at Ispra ever reached certification level, although all materials were produced according to the severe quality requirements requested for certified reference materials. Therefore, the materials not destinated to certification are in growing demand as inter-laboratory test materials and as laboratory reference materials, for internal quality control, e.g., by control charts. The history of reference material production within the Joint Research Centre is briefly reviewed and the latest additions described. New developments such as micro-scale reference materials intended for analytical methods requiring sample intakes at milligram or sub-milligram level and therefor not finding supply on the reference material market, and "wet" environmental reference materials, which meet more precisely the "real-world" environmental analysis conditions, are presented and the state-of-the-art discussed.

  12. 10 CFR 431.15 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... approval, and a notice of any change in the material will be published in the Federal Register. All... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.15 Section 431.15... INDUSTRIAL EQUIPMENT Electric Motors Test Procedures, Materials Incorporated and Methods of Determining...

  13. National Nutrition Education Clearing House Reference List, Secondary Teaching Materials and Teacher References.

    ERIC Educational Resources Information Center

    National Nutrition Education Clearing House, Berkeley, CA.

    A reference list of teaching materials and teacher guides in the field of nutrition is compiled in this pamphlet. Primary emphasis is on resources for secondary grades. The section on teaching materials includes books, pamphlets, leaflets, posters, charts, transparencies, ditto masters, kits, games, films, filmstrips, records, TV videotapes, and…

  14. 10 CFR 431.443 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the date of the approval and a notice of any change in the material will be published in the Federal... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.443 Section 431... AND INDUSTRIAL EQUIPMENT Small Electric Motors Test Procedures § 431.443 Materials incorporated by...

  15. New reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Gwinn, C. J.; Coplen, T. B.

    1993-01-01

    Three new reference materials were manufactured for calibration of relative stable nitrogen-isotope-ratio measurements: USGS25 (ammonium sulfate) d15N' = -30 per mil; USGS26 (ammonium sulfate) d15N' = +54 per mil; USGS32 (potassium nitrate) d15N' = +180 per mil, where d15N', relative to atmospheric nitrogen, is an approximate value subject to change following interlaboratory comparisons. These materials are isotopically homogeneous in aliquots at least as small as 10 µmol N2 (or about 1-2 mg of salt). The new reference materials greatly extend the range of d15N values of internationally distributed standards, and they allow normalization of d15N measurements over almost the full range of known natural isotope variation on Earth. The methods used to produce these materials may be adapted to produce homogeneous local laboratory standards for routine use.

  16. 40 CFR 90.7 - Reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Appendix A to subpart D, Table 3. ASTM D2699-92: Standard Test Method for Knock Characteristics of Motor... Knock Characteristics of Motor and Aviation Fuels by the Motor Method Appendix A to subpart D, Table 3...

  17. 40 CFR 90.7 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Appendix A to subpart D, Table 3. ASTM D2699-92: Standard Test Method for Knock Characteristics of Motor... Knock Characteristics of Motor and Aviation Fuels by the Motor Method Appendix A to subpart D, Table 3...

  18. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... incorporated by reference into this part. The Director of the Federal Register approved the incorporation by... and Radiation Docket and Information Center, 1301 Constitution Ave., NW., Room B102, EPA West Building.../federal_register/code_of_federal_regulations/ibr_locations.html. (a) IMO material. This paragraph (a...

  19. 40 CFR 1043.100 - Reference materials.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... this part. The Director of the Federal Register approved the incorporation by reference as prescribed... Docket and Information Center, 1301 Constitution Ave., NW., Room B102, EPA West Building, Washington, DC.../federal_register/code_of_federal_regulations/ibr_locations.html. (a) IMO material. This paragraph (a...

  20. 40 CFR 1043.100 - Reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... this part. The Director of the Federal Register approved the incorporation by reference as prescribed... Docket and Information Center, 1301 Constitution Ave., NW., Room B102, EPA West Building, Washington, DC.../federal_register/code_of_federal_regulations/ibr_locations.html. (a) IMO material. This paragraph (a...

  1. 40 CFR 1042.910 - Reference materials.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... incorporated by reference into this part. The Director of the Federal Register approved the incorporation by... and Radiation Docket and Information Center, 1301 Constitution Ave., NW., Room B102, EPA West Building.../federal_register/code_of_federal_regulations/ibr_locations.html. (a) IMO material. This paragraph (a...

  2. 40 CFR 1065.1010 - Reference materials.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... § 1065.1010—Institute of Petroleum Materials Document No. and name Part 1065 reference IP-470... atomic absorption spectrometry 1065.705 IP-500, Determination of the phosphorus content of residual fuels by ultra-violet spectrometry 1065.705 IP-501, Determination of aluminum, silicon, vanadium, nickel...

  3. Teaching about Asia: Professional Materials and Reference Books.

    ERIC Educational Resources Information Center

    Hantula, James N.

    This two-part document serves as a guide to basic materials on Asia. The first part provides the teacher of Asian studies with nonserial examples of pertinent professional materials and reference books in print since 1979. Criteria used in selecting the items are given and a brief comparison between materials available in 1969 and 1985 is made.…

  4. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  5. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  6. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  7. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  8. 14 CFR 171.71 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Headquarters. An historical file of these materials is maintained at Headquarters, Federal Aviation... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 171.71 Section 171.71 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION...

  9. [The water content reference material of water saturated octanol].

    PubMed

    Wang, Haifeng; Ma, Kang; Zhang, Wei; Li, Zhanyuan

    2011-03-01

    The national standards of biofuels specify the technique specification and analytical methods. A water content certified reference material based on the water saturated octanol was developed in order to satisfy the needs of the instrument calibration and the methods validation, assure the accuracy and consistency of results in water content measurements of biofuels. Three analytical methods based on different theories were employed to certify the water content of the reference material, including Karl Fischer coulometric titration, Karl Fischer volumetric titration and quantitative nuclear magnetic resonance. The consistency of coulometric and volumetric titration was achieved through the improvement of methods. The accuracy of the certified result was improved by the introduction of the new method of quantitative nuclear magnetic resonance. Finally, the certified value of reference material is 4.76% with an expanded uncertainty of 0.09%.

  10. 49 CFR 587.5 - Incorporated materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... incorporated by reference. For materials subject to change, only the specific version approved by the Director of the Federal Register and specified in the regulation are incorporated. A notice of any change will... reference are listed in the Finding Aid Table found at the end of this volume of the Code of Federal...

  11. Certification of biological candidates reference materials by neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Kabanov, Denis V.; Nesterova, Yulia V.; Merkulov, Viktor G.

    2018-03-01

    The paper gives the results of interlaboratory certification of new biological candidate reference materials by neutron activation analysis recommended by the Institute of Nuclear Chemistry and Technology (Warsaw, Poland). The correctness and accuracy of the applied method was statistically estimated for the determination of trace elements in candidate reference materials. The procedure of irradiation in the reactor thermal fuel assembly without formation of fast neutrons was carried out. It excluded formation of interfering isotopes leading to false results. The concentration of more than 20 elements (e.g., Ba, Br, Ca, Co, Ce, Cr, Cs, Eu, Fe, Hf, La, Lu, Rb, Sb, Sc, Ta, Th, Tb, Yb, U, Zn) in candidate references of tobacco leaves and bottom sediment compared to certified reference materials were determined. It was shown that the average error of the applied method did not exceed 10%.

  12. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the US Government`s Certifying Authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy (DOE) complex and at nuclear facilities around the world. Environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasis on requirementsmore » for characterization of waste materials, difficulties in transporting nuclear materials, and International factors, including International Atomic Energy Agency (IAEA) inspection of excess US nuclear materials, are all contributing influences. During these changing times, ft is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  13. A new basaltic glass microanalytical reference material for multiple techniques

    USGS Publications Warehouse

    Wilson, Steve; Koenig, Alan; Lowers, Heather

    2012-01-01

    The U.S. Geological Survey (USGS) has been producing reference materials since the 1950s. Over 50 materials have been developed to cover bulk rock, sediment, and soils for the geological community. These materials are used globally in geochemistry, environmental, and analytical laboratories that perform bulk chemistry and/or microanalysis for instrument calibration and quality assurance testing. To answer the growing demand for higher spatial resolution and sensitivity, there is a need to create a new generation of microanalytical reference materials suitable for a variety of techniques, such as scanning electron microscopy/X-ray spectrometry (SEM/EDS), electron probe microanalysis (EPMA), laser ablation inductively coupled mass spectrometry (LA-ICP-MS), and secondary ion mass spectrometry (SIMS). As such, the microanalytical reference material (MRM) needs to be stable under the beam, be homogeneous at scales of better than 10–25 micrometers for the major to ultra-trace element level, and contain all of the analytes (elements or isotopes) of interest. Previous development of basaltic glasses intended for LA-ICP-MS has resulted in a synthetic basaltic matrix series of glasses (USGS GS-series) and a natural basalt series of glasses (BCR-1G, BHVO-2G, and NKT-1G). These materials have been useful for the LA-ICP-MS community but were not originally intended for use by the electron or ion beam community. A material developed from start to finish with intended use in multiple microanalytical instruments would be useful for inter-laboratory and inter-instrument platform comparisons. This article summarizes the experiments undertaken to produce a basalt glass reference material suitable for distribution as a multiple-technique round robin material. The goal of the analytical work presented here is to demonstrate that the elemental homogeneity of the new glass is acceptable for its use as a reference material. Because the round robin exercise is still underway, only

  14. Certification of reference materials for the determination of alkylphenols.

    PubMed

    Hanari, Nobuyasu; Ishikawa, Keiichiro; Shimizu, Yoshitaka; Otsuka, Satoko; Iwasawa, Ryoko; Fujiki, Naomi; Numata, Masahiko; Yarita, Takashi; Kato, Kenji

    2015-04-01

    Certified reference materials (CRMs) are playing an increasingly important role in national and international standardizing activities. In Japan, primary standard solutions for analyses of endocrine disrupters are supplied under the national standards dissemination system named the Japan Calibration Service System (JCSS). For the traceability on reference materials used for preparation of the primary standard solutions based on the JCSS, the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed and certified high-purity reference materials of alkylphenols as NMIJ CRMs, such as 4-n-nonylphenol, 4-tert-octylphenol, 4-n-heptylphenol, 4-tert-butylphenol, and 2,4-dichlorophenol. Thereafter, it is essential to determine the alkylphenols by using these solutions based on the JCSS for environmental monitoring and risk assessments because analytical values obtained by using the solutions can ensure the reliability and traceability of the chemical analyses.

  15. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasismore » on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  16. Diffusion-controlled reference material for VOC emissions testing: proof of concept.

    PubMed

    Cox, S S; Liu, Z; Little, J C; Howard-Reed, C; Nabinger, S J; Persily, A

    2010-10-01

    Because of concerns about indoor air quality, there is growing awareness of the need to reduce the rate at which indoor materials and products emit volatile organic compounds (VOCs). To meet consumer demand for low emitting products, manufacturers are increasingly submitting materials to independent laboratories for emissions testing. However, the same product tested by different laboratories can result in very different emissions profiles because of a general lack of test validation procedures. There is a need for a reference material that can be used as a known emissions source and that will have the same emission rate when tested by different laboratories under the same conditions. A reference material was created by loading toluene into a polymethyl pentene film. A fundamental emissions model was used to predict the toluene emissions profile. Measured VOC emissions profiles using small-chamber emissions tests compared reasonably well to the emissions profile predicted using the emissions model, demonstrating the feasibility of the proposed approach to create a diffusion-controlled reference material. To calibrate emissions test chambers and improve the reproducibility of VOC emission measurements among different laboratories, a reference material has been created using a polymer film loaded with a representative VOC. Initial results show that the film's VOC emission profile measured in a conventional test chamber compares well to predictions based on independently determined material/chemical properties and a fundamental emissions model. The use of such reference materials has the potential to build consensus and confidence in emissions testing as well as 'level the playing field' for product testing laboratories and manufacturers.

  17. 40 CFR Table N-1 to Subpart N of... - CO2 Emission Factors for Carbonate-Based Raw Materials

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-Based Raw Materials N Table N-1 to Subpart N of Part 98 Protection of Environment ENVIRONMENTAL... Raw Materials Carbonate-basedraw material—mineral CO2 emission factor a Limestone—CaCO3 0.440 Dolomite... in units of metric tons of CO2 emitted per metric ton of carbonate-based raw material charged to the...

  18. 40 CFR Table 5 to Subpart Ooo of... - Reports Required by This Subpart

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Table 5 to Subpart OOO of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Resins Pt. 63, Subpt. OOO, Table 5 Table 5 to Subpart OOO of Part 63—Reports Required by This Subpart Reference Description of report Due date § 63.1400(j) and Subpart A of this part Refer to Table 1 and...

  19. 40 CFR Table 5 to Subpart Ooo of... - Reports Required by This Subpart

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Table 5 to Subpart OOO of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Resins Pt. 63, Subpt. OOO, Table 5 Table 5 to Subpart OOO of Part 63—Reports Required by This Subpart Reference Description of report Due date § 63.1400(j) and Subpart A of this part Refer to Table 1 and...

  20. 40 CFR Table 5 to Subpart Ooo of... - Reports Required by This Subpart

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Table 5 to Subpart OOO of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Resins Pt. 63, Subpt. OOO, Table 5 Table 5 to Subpart OOO of Part 63—Reports Required by This Subpart Reference Description of report Due date § 63.1400(j) and Subpart A of this part Refer to Table 1 and...

  1. [Development of the certified reference material of mercury in lyophilized human urine].

    PubMed

    Zhao, Wei; Zhang, Fu-gang; DU, Hui-fang; Pan, Ya-juan; Yan, Hui-fang

    2011-02-01

    To develop the certified reference material of mercury in lyophilized human urine. Human urine samples from normal level mercury districts were filtered, homogenized, dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories. The certified values are as follows: low level was (35.6 ± 2.1) µg/L, high level was (50.5 ± 3.0) µg/L. The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.

  2. Transportation research synthesis : ADA compliance reference and training materials.

    DOT National Transportation Integrated Search

    2010-03-01

    Our findings are presented in three categories: Reference Materials, Training Materials and State DOT Current : Practices. Appendix A to this report contains an updated list of ADA contacts for all 50 states and the District of : Columbia, and Append...

  3. Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Coplen, Tyler B.

    1995-01-01

    Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).

  4. Preparation and stability of milk somatic cell reference materials.

    PubMed

    Di Marzo, Larissa; Wojciechowski, Karen L; Barbano, David M

    2016-09-01

    Our objectives were to develop a method to produce milk somatic cell count (SCC) reference materials for calibration of electronic somatic cell count (ESCC) using gravity separation and to determine the effect of refrigerated storage (4°C) and freeze-thaw stability of the skim and whole milk SCC reference materials. Whole raw milk was high-temperature short-time pasteurized and split into 2 portions. One portion was gravity separated at 4°C for 22 h and the second portion was centrifugally separated to produce skim milk that was also gravity separated with somatic cells rising to the surface. After 22 h, stock solutions (low SCC skim milk, high SCC skim milk, high SCC whole milk) were prepared and preserved (bronopol). Two experiments were conducted, one to compare the shelf-life of skim and whole milk SCC standards at 4°C and one to determine the effect of freezing and thawing on SCC standards. Both experiments were replicated 3 times. Gravity separation was an effective approach to isolate and concentrate somatic cells from bovine milk and redistribute them in a skim or whole milk matrix to create a set of reference materials with a wider and more uniformly distributed range of SCC than current calibration sets. The liquid SCC reference materials stored using the common industry practice at 4°C were stable (i.e., fit for purpose, no large decrease in SCC) for a 2-wk period, whereas frozen and thawed reference materials may have a much longer useful life. A gradual decrease occurred in residual difference in ESCC (SCC × 1,000/mL) versus original assigned reference SCC over duration of refrigerated storage for both skim and whole milk SCC samples, indicating that milk ESCC of the preserved milks was gradually decreasing during 28 d of storage at 4°C by about 15,000 SCC/mL. No difference in the ESCC for skim milk was detected between refrigerated and frozen storage, whereas for whole milk the ESCC for frozen was lower than refrigerated samples. Future work is

  5. National Nutrition Education Clearing House Reference List, Preschool, Primary and Intermediate Teaching Materials and Teacher References.

    ERIC Educational Resources Information Center

    National Nutrition Education Clearing House, Berkeley, CA.

    This is a reference list of teaching materials and teacher references of importance to teachers in the field of nutrition and nutrition education. It emphasizes resources for preschool, primary and intermediate grades. Although not a comprehensive list, resources include books, pamphlets, curriculum guides, article reprints, films and filmstrips,…

  6. Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)

    USGS Publications Warehouse

    Brand, Willi A.; Coplen, Tyler B.; Vogl, Jochen; Rosner, Martin; Prohaska, Thomas

    2014-01-01

    Since the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.

  7. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 Pt. 53...

  8. 49 CFR 572.110 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Materials incorporated by reference. 572.110 Section 572.110 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Side...

  9. 49 CFR 572.110 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Materials incorporated by reference. 572.110 Section 572.110 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Side...

  10. 49 CFR 572.110 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Materials incorporated by reference. 572.110 Section 572.110 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Side...

  11. Kepler Certified False Positive Table

    NASA Technical Reports Server (NTRS)

    Bryson, Stephen T.; Batalha, Natalie Marie; Colon, Knicole Dawn; Coughlin, Jeffrey Langer; Haas, Michael R.; Henze, Chris; Huber, Daniel; Morton, Tim; Rowe, Jason Frank; Mullally, Susan Elizabeth; hide

    2017-01-01

    This document describes the Kepler Certied False Positive table hosted at the Exoplanet Archive1, herein referred to as the CFP table. This table is the result of detailed examination by the Kepler False Positive Working Group (FPWG) of declared false positives in the Kepler Object of Interest (KOI) tables (see, for example, Batalha et al. (2012); Burke et al.(2014); Rowe et al. (2015); Mullally et al. (2015); Coughlin et al. (2015b)) at the Exoplanet Archive. A KOI is considered a false positive if it is not due to a planet orbiting the KOI's target star. The CFP table contains all KOIs in the Exoplanet Archive cumulative KOI table. The purpose of the CFP table is to provide a list of certified false positive KOIs. A KOI is certified as a false positive when, in the judgement of the FPWG, there is no plausible planetary interpretation of the observational evidence, which we summarize by saying that the evidence for a false positive is compelling. This certification process involves detailed examination using all available data for each KOI, establishing a high-reliability ground truth set. The CFP table can be used to estimate the reliability of, for example, the KOI tables which are created using only Kepler photometric data, so the disposition of individual KOIs may differ in the KOI and CFP tables. Follow-up observers may find the CFP table useful to avoid observing false positives.

  12. Preparation of canine C-reactive protein serum reference material: A feasibility study.

    PubMed

    Canalias, Francesca; Piñeiro, Matilde; Pato, Raquel; Peña, Raquel; Bosch, Lluís; Soler, Lourdes; García, Natalia; Lampreave, Fermín; Saco, Yolanda; Bassols, Anna

    2018-03-01

    The availability of a species-specific reference material is essential for the harmonization of results obtained in different laboratories by different methods. We describe the preparation of a canine C-reactive protein (cCRP) serum reference material containing purified cCRP stabilized in a serum matrix. The material can be used by manufacturers to assign values to their calibrator and control materials. The serum matrix was obtained using blood collected from healthy dogs, stabilized and submitted for a delipidation process. The reference material was prepared by diluting purified cCRP in the serum matrix containing 1.0 mol/L HEPES buffer, 3.0 mmol/L calcium chloride, 80,000 kUI/L aprotinin, and 1.0 mmol/L benzamidine hydrochloride monohydrate at a pH of 7.2, and dispensing (0.5 mL) the matrix into vials that were then frozen. The pilot batch of 200 vials was shown to be homogeneous and stable after a stability study at various temperatures and over a total time of 110 days. The prepared material was submitted to an assignment value study. Eight laboratories from different European countries participated by using the same reagents for an immunoturbidimetric method adapted for different analyzers. The obtained cCRP concentration in the reference material was 78.5 mg/L with an expanded uncertainty (k = 2) of 4.2 mg/L. Canine C-reactive protein serum reference material has been produced that allows harmonization of results obtained by different methods and different laboratories, thus reducing the possibility of errors and misunderstandings. © 2018 American Society for Veterinary Clinical Pathology.

  13. Standard and reference materials for marine science. Third edition. Technical memo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantillo, A.Y.

    1992-08-01

    The third edition of the catalog of reference materials suited for use in marine science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists close to 2,000 reference materials from sixteen producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds. The catalog is being published independently by both NOAA and IOC/UNEP and is available from NOAA/NOS/ORCA in electronic form.

  14. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  15. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  16. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  17. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  18. 9 CFR 77.1 - Material incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AGRICULTURE INTERSTATE TRANSPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS TUBERCULOSIS General Provisions § 77.1 Material incorporated by reference. Uniform Methods and Rules—Bovine Tuberculosis Eradication. The Uniform Methods and Rules—Bovine Tuberculosis Eradication (January 22, 1999, edition) has...

  19. Toward Worldwide Hepcidin Assay Harmonization: Identification of a Commutable Secondary Reference Material.

    PubMed

    van der Vorm, Lisa N; Hendriks, Jan C M; Laarakkers, Coby M; Klaver, Siem; Armitage, Andrew E; Bamberg, Alison; Geurts-Moespot, Anneke J; Girelli, Domenico; Herkert, Matthias; Itkonen, Outi; Konrad, Robert J; Tomosugi, Naohisa; Westerman, Mark; Bansal, Sukhvinder S; Campostrini, Natascia; Drakesmith, Hal; Fillet, Marianne; Olbina, Gordana; Pasricha, Sant-Rayn; Pitts, Kelly R; Sloan, John H; Tagliaro, Franco; Weykamp, Cas W; Swinkels, Dorine W

    2016-07-01

    Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary reference material to accomplish this goal. We applied technical procedures to achieve harmonization developed by the Consortium for Harmonization of Clinical Laboratory Results. Eleven plasma hepcidin measurement procedures (5 mass spectrometry based and 6 immunochemical based) quantified native individual plasma samples (n = 32) and native plasma pools (n = 8) to assess analytical performance and current and achievable equivalence. In addition, 8 types of candidate reference materials (3 concentrations each, n = 24) were assessed for their suitability, most notably in terms of commutability, to serve as secondary reference material. Absolute hepcidin values and reproducibility (intrameasurement procedure CVs 2.9%-8.7%) differed substantially between measurement procedures, but all were linear and correlated well. The current equivalence (intermeasurement procedure CV 28.6%) between the methods was mainly attributable to differences in calibration and could thus be improved by harmonization with a common calibrator. Linear regression analysis and standardized residuals showed that a candidate reference material consisting of native lyophilized plasma with cryolyoprotectant was commutable for all measurement procedures. Mathematically simulated harmonization with this calibrator resulted in a maximum achievable equivalence of 7.7%. The secondary reference material identified in this study has the potential to substantially improve equivalence between hepcidin measurement procedures and contributes to the establishment of a traceability chain that will ultimately allow standardization of hepcidin measurement results. © 2016 American Association for Clinical Chemistry.

  20. Supplemental Tables to the Annual Energy Outlook

    EIA Publications

    2017-01-01

    The Annual Energy Outlook (AEO) Supplemental tables were generated for the reference case of the AEO using the National Energy Modeling System, a computer-based model which produces annual projections of energy markets. Most of the tables were not published in the AEO, but contain regional and other more detailed projections underlying the AEO projections.

  1. 10 CFR 435.3 - Material incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Material incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435...

  2. 10 CFR 435.3 - Material incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Material incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435...

  3. 10 CFR 431.293 - Materials incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2010-01-01 2010-01-01 false Materials incorporated by reference. 431.293 Section 431.293 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  4. 10 CFR 433.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 433.3 Section 433.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL COMMERCIAL.... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, Sixth...

  5. 10 CFR 431.293 - Materials incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2011-01-01 2011-01-01 false Materials incorporated by reference. 431.293 Section 431.293 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  6. 10 CFR 431.293 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 431.293 Section 431.293 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  7. 10 CFR 431.63 - Materials incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2011-01-01 2011-01-01 false Materials incorporated by reference. 431.63 Section 431.63 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  8. 10 CFR 431.95 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Energy Efficiency and Renewable Energy, Hearings and Dockets, “Test Procedures and Efficiency Standards... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 431.95 Section 431.95 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  9. 10 CFR 431.323 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 431.323 Section 431.323 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  10. 10 CFR 431.105 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor, 950 L'Enfant... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.105 Section 431.105 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  11. 10 CFR 431.63 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.63 Section 431.63 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  12. 10 CFR 431.105 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor, 950 L'Enfant... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 431.105 Section 431.105 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  13. 10 CFR 433.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 433.3 Section 433.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL COMMERCIAL.... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, Sixth...

  14. 10 CFR 431.63 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 431.63 Section 431.63 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  15. 10 CFR 431.293 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.293 Section 431.293 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  16. 10 CFR 431.293 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 431.293 Section 431.293 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  17. 10 CFR 431.63 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    .... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 431.63 Section 431.63 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  18. 10 CFR 433.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 433.3 Section 433.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL COMMERCIAL.... Department of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, Sixth...

  19. 10 CFR 431.323 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.323 Section 431.323 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL...

  20. Table-sized matrix model in fractional learning

    NASA Astrophysics Data System (ADS)

    Soebagyo, J.; Wahyudin; Mulyaning, E. C.

    2018-05-01

    This article provides an explanation of the fractional learning model i.e. a Table-Sized Matrix model in which fractional representation and its operations are symbolized by the matrix. The Table-Sized Matrix are employed to develop problem solving capabilities as well as the area model. The Table-Sized Matrix model referred to in this article is used to develop an understanding of the fractional concept to elementary school students which can then be generalized into procedural fluency (algorithm) in solving the fractional problem and its operation.

  1. 10 CFR 435.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE... Renewable Energy, Building Technologies Program, Sixth Floor, 950 L'Enfant Plaza, SW., Washington, DC 20024...

  2. 10 CFR 431.75 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... available for inspection at U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 431.75 Section 431.75 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  3. 10 CFR 431.75 - Materials incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... available for inspection at U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy... 10 Energy 3 2014-01-01 2014-01-01 false Materials incorporated by reference. 431.75 Section 431.75 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND...

  4. 10 CFR 435.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Materials incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE... Renewable Energy, Building Technologies Program, Sixth Floor, 950 L'Enfant Plaza, SW., Washington, DC 20024...

  5. 10 CFR 435.3 - Materials incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Materials incorporated by reference. 435.3 Section 435.3 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE... Renewable Energy, Building Technologies Program, Sixth Floor, 950 L'Enfant Plaza, SW., Washington, DC 20024...

  6. [Effect of emotional content and self reference of learning materials on recall performance].

    PubMed

    Spies, K

    1994-01-01

    It is assumed that high affective value and high self-reference of learning material help to improve memory performance as these factors allow better memory consolidation (activation hypothesis) or better integration of the new material into existing knowledge structures (extent-of-processing hypothesis). To test this assumption, 60 subjects were shown 16 short advertising films characterized by low vs. high affective value and low vs. high self-reference. Both factors were varied within subjects. After the films had each been presented twice, subjects had to recall the product names and answer two questions to each film. Results showed for both dependent variables that films with high affective values were better remembered than films with low affective values. The same held true--though to a lower extent--with respect to self-reference. According to the expected linear trend, performance was best for material scoring high on affective value as well as on self-reference, while it was worst for material scoring low on both factors.

  7. [Development and application of reference materials containing mixed degradation products of amoxicillin and ampicillin].

    PubMed

    Li, Wei; Zhang, Wei-Qing; Li, Xiang; Hu, Chang-Qin

    2014-09-01

    Reference materials containing mixed degradation products of amoxicillin and ampicillin were developed after optimization of preparation processes. The target impurities were obtained by controlled stress testing, and each major component was identified with HPLC-MS and compared with single traceable reference standard each. The developed reference materials were applied to system suitability test for verifying HPLC system performed in accordance with set forth in China Pharmacopeia and identification of major impurities in samples based on retention and spectra information, which have advantages over the methods put forth in foreign pharmacopoeias. The development and application of the reference materials offer an effective way for rapid identification of impurities in chromatograms, and provide references for analyzing source of impurities and evaluation of drug quality.

  8. 5 CFR 294.401 - References.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false References. 294.401 Section 294.401 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS AVAILABILITY OF OFFICIAL INFORMATION Cross References § 294.401 References. The table below provides assistance in locating other OPM...

  9. Interlaboratory comparison program for nondestructive assay of prototype uranium reference materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trahey, N.M.; Smith, M.M.; Voeks, A.M.

    The US Department of Energy (DOE), New Brunswick Laboratory (NBS), designed and administered an interlaboratory comparison program based on the measurement of NBL-produced prototype uranium nondestructive assay (NDA) reference materials for scrap and waste. The objectives of the program were to evaluate the reliability of NDA techniques as applied to nuclear safeguards materials control and accountability needs and to investigate the feasibility of providing practical NDA scrap and waste reference materials for use throughout the nuclear safeguards community. Fourteen facilities representing seven DOE contractors, four US Nuclear Regulatory Commission (NRC) licensees, one EURATOM Laboratory, and NBL, participated in this program.more » Three stable, well-characterized uranium reference materials were developed and certified for this program. Synthetic calcined ash, cellulose fiber, and ion-exchange resin simulate selected uranium scrap and waste forms which are often encountered in fabrication and recovery operations. The synthetic calcined ash represents an intermediate density inorganic matrix while the cellulose fiber and ion-exchange resin are representative of low-density organic matrices. The materials, containing from 0 to 13% uranium enriched at 93% /sup 235/U, were sealed in specially selected containers. Nineteen prototype reference samples, plus three empty containers, one to accompany each set, was circulated to the participants between August 1979 and May 1984. Triplicate measurements for /sup 235/U on each of the 19 filled containers were required. In addition, participants could opt to perform modular configuration measurements using containers from Sets IIA and IIB to simulate non-homogeneously dispersed uranium in waste containers. All data were reported to NBL for evaluation.« less

  10. APEX (Air Pollution Exercise) Volume 20: Reference Materials.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Research Triangle Park, NC. Office of Manpower Development.

    The Reference Materials Manual is part of a set of 21 manuals (AA 001 009-001 029) used in APEX (Air Pollution Exercise), a computerized college and professional level "real world" game simulation of a community with urban and rural problems, industrial activities, and air pollution difficulties. For the purposes of the gaming exercise, APEX…

  11. High-precision isotopic characterization of USGS reference materials by TIMS and MC-ICP-MS

    NASA Astrophysics Data System (ADS)

    Weis, Dominique; Kieffer, Bruno; Maerschalk, Claude; Barling, Jane; de Jong, Jeroen; Williams, Gwen A.; Hanano, Diane; Pretorius, Wilma; Mattielli, Nadine; Scoates, James S.; Goolaerts, Arnaud; Friedman, Richard M.; Mahoney, J. Brian

    2006-08-01

    The Pacific Centre for Isotopic and Geochemical Research (PCIGR) at the University of British Columbia has undertaken a systematic analysis of the isotopic (Sr, Nd, and Pb) compositions and concentrations of a broad compositional range of U.S. Geological Survey (USGS) reference materials, including basalt (BCR-1, 2; BHVO-1, 2), andesite (AGV-1, 2), rhyolite (RGM-1, 2), syenite (STM-1, 2), granodiorite (GSP-2), and granite (G-2, 3). USGS rock reference materials are geochemically well characterized, but there is neither a systematic methodology nor a database for radiogenic isotopic compositions, even for the widely used BCR-1. This investigation represents the first comprehensive, systematic analysis of the isotopic composition and concentration of USGS reference materials and provides an important database for the isotopic community. In addition, the range of equipment at the PCIGR, including a Nu Instruments Plasma MC-ICP-MS, a Thermo Finnigan Triton TIMS, and a Thermo Finnigan Element2 HR-ICP-MS, permits an assessment and comparison of the precision and accuracy of isotopic analyses determined by both the TIMS and MC-ICP-MS methods (e.g., Nd isotopic compositions). For each of the reference materials, 5 to 10 complete replicate analyses provide coherent isotopic results, all with external precision below 30 ppm (2 SD) for Sr and Nd isotopic compositions (27 and 24 ppm for TIMS and MC-ICP-MS, respectively). Our results also show that the first- and second-generation USGS reference materials have homogeneous Sr and Nd isotopic compositions. Nd isotopic compositions by MC-ICP-MS and TIMS agree to within 15 ppm for all reference materials. Interlaboratory MC-ICP-MS comparisons show excellent agreement for Pb isotopic compositions; however, the reproducibility is not as good as for Sr and Nd. A careful, sequential leaching experiment of three first- and second-generation reference materials (BCR, BHVO, AGV) indicates that the heterogeneity in Pb isotopic compositions

  12. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  13. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  14. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  15. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  16. Determination of Perfluorinated Alkyl Acid Concentrations in Biological Standard Reference Materials

    EPA Science Inventory

    Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned ...

  17. Analysis of standard reference materials by absolute INAA

    NASA Astrophysics Data System (ADS)

    Heft, R. E.; Koszykowski, R. F.

    1981-07-01

    Three standard reference materials: flyash, soil, and ASI 4340 steel, are analyzed by a method of absolute instrumental neutron activation analysis. Two different light water pool-type reactors were used to produce equivalent analytical results even though the epithermal to thermal flux ratio in one reactor was higher than that in the other by a factor of two.

  18. Bibliography of Testing and Evaluation Reference Material

    DTIC Science & Technology

    1989-08-01

    Society. ** [Basl84a] Basili, V.R., and J. Ramsey . September 1984. Structural Coverage of Functional Testing . University of Maryland. Technical Report TR...r’V1 r~CN <T { L Copy 2 0 of 36 copies N FINAL cc CID It- IDA MEMORANDUM REPORT M-496 BIBLIOGRAPHY OF TESTING AND EVALUATION REFERENCE MATERIAL Bill...blank) 2. REPORT DATE 3. REPORT TYPE AND DATES COVERED August 1989 Final -TITLE AND SUBTITLE 5. FUNDING NUMBERS * Bibliography of Testing and

  19. Homogeneity study of a corn flour laboratory reference material candidate for inorganic analysis.

    PubMed

    Dos Santos, Ana Maria Pinto; Dos Santos, Liz Oliveira; Brandao, Geovani Cardoso; Leao, Danilo Junqueira; Bernedo, Alfredo Victor Bellido; Lopes, Ricardo Tadeu; Lemos, Valfredo Azevedo

    2015-07-01

    In this work, a homogeneity study of a corn flour reference material candidate for inorganic analysis is presented. Seven kilograms of corn flour were used to prepare the material, which was distributed among 100 bottles. The elements Ca, K, Mg, P, Zn, Cu, Fe, Mn and Mo were quantified by inductively coupled plasma optical emission spectrometry (ICP OES) after acid digestion procedure. The method accuracy was confirmed by analyzing the rice flour certified reference material, NIST 1568a. All results were evaluated by analysis of variance (ANOVA) and principal component analysis (PCA). In the study, a sample mass of 400mg was established as the minimum mass required for analysis, according to the PCA. The between-bottle test was performed by analyzing 9 bottles of the material. Subsamples of a single bottle were analyzed for the within-bottle test. No significant differences were observed for the results obtained through the application of both statistical methods. This fact demonstrates that the material is homogeneous for use as a laboratory reference material. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Development of candidate reference materials for the measurement of lead in bone

    PubMed Central

    Hetter, Katherine M.; Bellis, David J.; Geraghty, Ciaran; Todd, Andrew C.; Parsons, Patrick J.

    2010-01-01

    The production of modest quantities of candidate bone lead (Pb) reference materials is described, and an optimized production procedure is presented. The reference materials were developed to enable an assessment of the interlaboratory agreement of laboratories measuring Pb in bone; method validation; and for calibration of solid sampling techniques such as laser ablation ICP-MS. Long bones obtained from Pb-dosed and undosed animals were selected to produce four different pools of a candidate powdered bone reference material. The Pb concentrations of these pools reflect both environmental and occupational exposure levels in humans. The animal bones were harvested post mortem, cleaned, defatted, and broken into pieces using the brittle fracture technique at liquid nitrogen temperature. The bone pieces were then ground in a knife mill to produce fragments of 2-mm size. These were further ground in an ultra-centrifugal mill, resulting in finely powdered bone material that was homogenized and then sampled-scooped into vials. Testing for contamination and homogeneity was performed via instrumental methods of analysis. PMID:18421443

  1. Carboxyhaemoglobin: a possible reference material for haemoglobin assay.

    PubMed Central

    Rideout, J M; Louderback, A

    1982-01-01

    The inter- and intralaboratory quality control of haemoglobin estimation in remote laboratories requires a more rugged control haemolysate than is commercially available. The stabilities of oxyhaemoglobin and carboxyhaemoglobin forms of an ethanediol-containing haemolysate were studied over a three-year period. From the results obtained, carboxyhaemoglobin under nitrogen is proposed as a possible candidate reference material for haemoglobin assay. PMID:7068921

  2. MIL-HDBK-338-Environmental Conversion Table Correction

    NASA Technical Reports Server (NTRS)

    Hark, Frank; Novack, Steve

    2017-01-01

    In reliability analysis for space launch vehicles, limited data is frequently a challenge due to the pure number of launches. A common solution is to use surrogate historical data of similar components from other industries (military data). The operating environment of the common data may be different from that of the necessary target analysis. The military electronic design handbook (MIL-HDBK-338) has a table for converting Mean Time Between Failure (MTBF) data from one environment to another. However, the table has some discrepancies and rounding of complementary conversions; namely going from environment A to B does not given the same result as going from B to A. This presentation will show the discrepancies in the original conversation table, the greater than expected magnitude, the problem with the updated published table and a suggested corrected table to reference when doing MTBF data environment conversion.

  3. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    PubMed

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  4. Requirements for the Development of Bacillus Anthracis Spore Reference Materials Used to Test Detection Systems

    PubMed Central

    Almeida, Jamie L.; Wang, Lili; Morrow, Jayne B.; Cole, Kenneth D.

    2006-01-01

    Bacillus anthracis spores have been used as biological weapons and the possibility of their further use requires surveillance systems that can accurately and reliably detect their presence in the environment. These systems must collect samples from a variety of matrices, process the samples, and detect the spores. The processing of the sample may include removal of inhibitors, concentration of the target, and extraction of the target in a form suitable for detection. Suitable reference materials will allow the testing of each of these steps to determine the sensitivity and specificity of the detection systems. The development of uniform and well-characterized reference materials will allow the comparison of different devices and technologies as well as assure the continued performance of detection systems. This paper discusses the special requirements of reference materials for Bacillus anthracis spores that could be used for testing detection systems. The detection of Bacillus anthracis spores is based on recognition of specific characteristics (markers) on either the spore surface or in the nucleic acids (DNA). We have reviewed the specific markers and their relevance to characterization of reference materials. We have also included the approach for the characterization of candidate reference materials that we are developing at the NIST laboratories. Additional applications of spore reference materials would include testing sporicidal treatments, techniques for sampling the environment, and remediation of spore-contaminated environments. PMID:27274929

  5. 40 CFR Table 5 to Subpart Ooo of... - Reports Required by This Subpart

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Table 5 to Subpart OOO of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Amino/Phenolic Resins Pt. 63, Subpt. OOO, Table 5 Table 5 to Subpart OOO of Part 63—Reports Required by... Table 1 and Subpart A of this part Refer to Subpart A of this part. 63.1417(d) Precompliance Report...

  6. 40 CFR Table 5 to Subpart Ooo of... - Reports Required by This Subpart

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Table 5 to Subpart OOO of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Amino/Phenolic Resins Pt. 63, Subpt. OOO, Table 5 Table 5 to Subpart OOO of Part 63—Reports Required by... Table 1 and Subpart A of this part Refer to Subpart A of this part. 63.1417(d) Precompliance Report...

  7. 26 CFR 1.401(a)(9)-9 - Life expectancy and distribution period tables.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 5 2014-04-01 2014-04-01 false Life expectancy and distribution period tables... Plans, Etc. § 1.401(a)(9)-9 Life expectancy and distribution period tables. Q-1. What is the life...)(9)? A-1 The following table, referred to as the Single Life Table, is used for determining the life...

  8. Development of certified reference materials for electrolytes in human serum (GBW09124-09126).

    PubMed

    Feng, Liuxing; Wang, Jun; Cui, Yanjie; Shi, Naijie; Li, Haifeng; Li, Hongmei

    2017-05-01

    Three reference materials, at relatively low, middle, and high concentrations, were developed for analysis of the mass fractions of electrolytes (K, Ca, Na, Mg, Cl, and Li) in human serum. The reference materials were prepared by adding high purity chloride salts to normal human serum. The concentration range of the three levels is within ±20% of normal human serum. It was shown that 14 units with duplicate analysis is enough to demonstrate the homogeneity of these candidate reference materials. The statistical results also showed no significant trends in both short-term stability test for 1 week at 40 °C and long-term stability test for 14 months. The certification methods of the six elements include isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS), inductively coupled plasma optical emission spectroscopy (ICP-OES), atomic absorption spectroscopy (AAS), ion chromatography (IC), and ion-selective electrode (ISE). The certification methods were validated by international comparisons among a number of national metrology institutes (NMIs). The combined relative standard uncertainties of the property values were estimated by considering the uncertainties of the analytical methods, homogeneity, and stability. The range of the expanded uncertainties of all the elements is from 2.2% to 3.9%. The certified reference materials (CRMs) are primarily intended for use in the calibration and validation of procedures in clinical analysis for the determination of electrolytes in human serum or plasma. Graphical Abstract Certified reference materials for K, Ca, Mg, Na, Cl and Li in human serum (GBW09124-09126).

  9. NIST gold nanoparticle reference materials do not induce oxidative DNA damage.

    PubMed

    Nelson, Bryant C; Petersen, Elijah J; Marquis, Bryce J; Atha, Donald H; Elliott, John T; Cleveland, Danielle; Watson, Stephanie S; Tseng, I-Hsiang; Dillon, Andrew; Theodore, Mellisa; Jackman, Joany

    2013-02-01

    One primary challenge in nanotoxicology studies is the lack of well-characterised nanoparticle reference materials which could be used as positive or negative nanoparticle controls. The National Institute of Standards and Technology (NIST) has developed three gold nanoparticle (AuNP) reference materials (10, 30 and 60 nm). The genotoxicity of these nanoparticles was tested using HepG2 cells and calf-thymus DNA. DNA damage was assessed based on the specific and sensitive measurement of four oxidatively-modified DNA lesions (8-hydroxy-2´-deoxyguanosine, 8-hydroxy-2´-deoxyadenosine, (5´S)-8,5´-cyclo-2´-deoxyadenosine and (5´R)-8,5´-cyclo-2´-deoxyadenosine) using liquid chromatography/tandem mass spectrometry. Significantly elevated, dose-dependent DNA damage was not detected at concentrations up to 0.2 μg/ml, and free radicals were not detected using electron paramagnetic resonance spectroscopy. These data suggest that the NIST AuNPs could potentially serve as suitable negative-control nanoparticle reference materials for in vitro and in vivo genotoxicity studies. NIST AuNPs thus hold substantial promise for improving the reproducibility and reliability of nanoparticle genotoxicity studies.

  10. Development of new reference material neohesperidin for quality control of dietary supplements.

    PubMed

    Gong, Ningbo; Zhang, Baoxi; Yang, Dezhi; Gao, Zhaolin; Du, Guanhua; Lu, Yang

    2015-07-01

    Neohesperidin is an important natural flavanone glycoside distributed in several citrus species. This compound is widely used as a raw material for food additives in the food industry. The request for certified reference materials (CRMs) in dietary supplements was stipulated by the National Administrative Committee for CRMs and was underpinned by the need to improve the accuracy and comparability of measurement data and to establish metrological traceability of analytical results. This paper reports the sample preparation methodology, homogeneity and stability studies, value assignment and uncertainty estimation of a new certified reference material of neohesperidin (GBW09522). Differential scanning calorimetry, coulometric titration and mass balance methods proved to be sufficiently reliable and accurate for certification purposes. The certified value of neohesperidin CRM is 994 g kg(-1) with an expanded uncertainty of 4 g kg(-1) (k = 2). The reference material described above was homogeneous and stable for 12 months at a storage temperature of 25 °C. The new CRM of neohesperidin can be used to validate analytical methods and improve the accuracy of measurement data as well as quality control of neohesperidin-related dietary supplements, foods, traditional herbs and pharmaceutical formulations. © 2014 Society of Chemical Industry.

  11. Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions

    National Institute of Standards and Technology Data Gateway

    SRD 124 NISStopping-Power and Range Tables for Electrons, Protons, and Helium Ions (Web, free access)   The databases ESTAR, PSTAR, and ASTAR calculate stopping-power and range tables for electrons, protons, or helium ions. Stopping-power and range tables can be calculated for electrons in any user-specified material and for protons and helium ions in 74 materials.

  12. Queuing Theory and Reference Transactions.

    ERIC Educational Resources Information Center

    Terbille, Charles

    1995-01-01

    Examines the implications of applying the queuing theory to three different reference situations: (1) random patron arrivals; (2) random durations of transactions; and (3) use of two librarians. Tables and figures represent results from spreadsheet calculations of queues for each reference situation. (JMV)

  13. Characterization of Ricin and R. communis Agglutinin Reference Materials.

    PubMed

    Worbs, Sylvia; Skiba, Martin; Söderström, Martin; Rapinoja, Marja-Leena; Zeleny, Reinhard; Russmann, Heiko; Schimmel, Heinz; Vanninen, Paula; Fredriksson, Sten-Åke; Dorner, Brigitte G

    2015-11-26

    Ricinus communis intoxications have been known for centuries and were attributed to the toxic protein ricin. Due to its toxicity, availability, ease of preparation, and the lack of medical countermeasures, ricin attracted interest as a potential biological warfare agent. While different technologies for ricin analysis have been established, hardly any universally agreed-upon "gold standards" are available. Expert laboratories currently use differently purified in-house materials, making any comparison of accuracy and sensitivity of different methods nearly impossible. Technically challenging is the discrimination of ricin from R. communis agglutinin (RCA120), a less toxic but highly homologous protein also contained in R. communis. Here, we established both highly pure ricin and RCA120 reference materials which were extensively characterized by gel electrophoresis, liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI MS/MS), and matrix-assisted laser desorption ionization-time of flight approaches as well as immunological and functional techniques. Purity reached >97% for ricin and >99% for RCA120. Different isoforms of ricin and RCA120 were identified unambiguously and distinguished by LC-ESI MS/MS. In terms of function, a real-time cytotoxicity assay showed that ricin is approximately 300-fold more toxic than RCA120. The highly pure ricin and RCA120 reference materials were used to conduct an international proficiency test.

  14. The table of isotopes-8th edition and beyond

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Firestone, R.B.

    A new edition of the Table of Isotopes has been published this year by John Wiley and Sons, Inc. This edition is the eighth in a series started by Glenn T. Seaborg in 1940. The two-volume, 3168-page, cloth-bound edition is twice the size of the previous edition published in 1978. It contains nuclear structure and decay data, based mainly on the Evaluated Nuclear Structure Data File (ENSDF), for >3100 isotopes and isomers. Approximately 24000 references are cited, and the appendices have been updated and extended. The book is packaged with an interactive CD-ROM that contains the Table of Isotopes inmore » Adobe Acrobat Portable Document Format for convenient viewing on personal computer (PC) and UNIX workstations. The CD-ROM version contains a chart of the nuclides graphical index and separate indices organized for radioisotope users and nuclear structure physicists. More than 100000 hypertext links are provided to move the user quickly through related information free from the limitations of page size. Complete references with keyword abstracts are provided. The CD-ROM also contains the Table of Super-deformed Nuclear Bands and Fission Isomers; Tables of Atoms, Atomic Nuclei, and Subatomic Particles by Ivan P. Selinov; the ENSDF and nuclear structure reference (NSR) databases; the ENSDF manual by Jagdish K. Tuli; and Abode Acrobat Reader software.« less

  15. [Report of the NEDO project "Research and development to promote the creation and utilization of an intellectual infrastructure: development of reference materials for laboratory medicine" "Development of pure substance-type certified reference materials"].

    PubMed

    Takatsu, Akiko

    2009-06-01

    There is an increasing demand to establish a metrological traceability system for in vitro diagnostics and medical devices. Pure substance-type reference materials are playing key roles in metrological traceability, because they form the basis for many traceability chains in chemistry. The National Metrology Institute of Japan (NMIJ), in the National Institute of Advanced Industrial Science and Technology (AIST), has been developing purity-certified reference materials (CRMs) in this field, such as cholesterol, creatinine, and urea. In the New Energy and Industrial Technology Development Organization (NEDO) project, entitled: "Research and Development to Promote the Creation and Utilization of an Intellectual Infrastructure: Development of Reference Materials for Laboratory Medicine", several pure substance-type CRMs were developed. For a pure protein solution CRM, amino acid analysis and nitrogen determination were chosen as the certification methods. The development and certification processes for the C-reactive protein (CRP) solution CRM were completed, with the recombinant human CRP solution as a candidate material. This CRP solution CRM is now available as NMIJ CRM. For cortisol CRM, a purified candidate material and highly pure primary reference material were prepared. Each impure compound in the materials was identified and quantified. The pure cortisol CRM will be available in 2009. These two CRMs provide a traceability link between routine clinical methods and the SI unit.

  16. Compositional analysis of biomass reference materials: Results from an interlaboratory study

    DOE PAGES

    Templeton, David W.; Wolfrum, Edward J.; Yen, James H.; ...

    2015-10-29

    Biomass compositional methods are used to compare different lignocellulosic feedstocks, to measure component balances around unit operations and to determine process yields and therefore the economic viability of biomass-to-biofuel processes. Four biomass reference materials (RMs NIST 8491–8494) were prepared and characterized, via an interlaboratory comparison exercise in the early 1990s to evaluate biomass summative compositional methods, analysts, and laboratories. Having common, uniform, and stable biomass reference materials gives the opportunity to assess compositional data compared to other analysts, to other labs, and to a known compositional value. The expiration date for the original characterization of these RMs was reached andmore » an effort to assess their stability and recharacterize the reference values for the remaining material using more current methods of analysis was initiated. We sent samples of the four biomass RMs to 11 academic, industrial, and government laboratories, familiar with sulfuric acid compositional methods, for recharacterization of the component reference values. In this work, we have used an expanded suite of analytical methods that are more appropriate for herbaceous feedstocks, to recharacterize the RMs’ compositions. We report the median values and the expanded uncertainty values for the four RMs on a dry-mass, whole-biomass basis. The original characterization data has been recalculated using median statistics to facilitate comparisons with this data. We found improved total component closures for three out of the four RMs compared to the original characterization, and the total component closures were near 100 %, which suggests that most components were accurately measured and little double counting occurred. Here, the major components were not statistically different in the recharacterization which suggests that the biomass materials are stable during storage and that additional components, not seen in the original

  17. Interlaboratory Reproducibility of Droplet Digital Polymerase Chain Reaction Using a New DNA Reference Material Format.

    PubMed

    Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R

    2017-11-07

    Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.

  18. 29 CFR 1910.122 - Table of contents.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 5 2012-07-01 2012-07-01 false Table of contents. 1910.122 Section 1910.122 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Hazardous Materials Dipping and Coating Operations § 1910.122 Table of...

  19. Development of Lentivirus-Based Reference Materials for Ebola Virus Nucleic Acid Amplification Technology-Based Assays.

    PubMed

    Mattiuzzo, Giada; Ashall, James; Doris, Kathryn S; MacLellan-Gibson, Kirsty; Nicolson, Carolyn; Wilkinson, Dianna E; Harvey, Ruth; Almond, Neil; Anderson, Robert; Efstathiou, Stacey; Minor, Philip D; Page, Mark

    2015-01-01

    The 2013-present Ebola virus outbreak in Western Africa has prompted the production of many diagnostic assays, mostly based on nucleic acid amplification technologies (NAT). The calibration and performance assessment of established assays and those under evaluation requires reference materials that can be used in parallel with the clinical sample to standardise or control for every step of the procedure, from extraction to the final qualitative/quantitative result. We have developed safe and stable Ebola virus RNA reference materials by encapsidating anti sense viral RNA into HIV-1-like particles. The lentiviral particles are replication-deficient and non-infectious due to the lack of HIV-1 genes and Envelope protein. Ebola virus genes were subcloned for encapsidation into two lentiviral preparations, one containing NP-VP35-GP and the other VP40 and L RNA. Each reference material was formulated as a high-titre standard for use as a calibrator for secondary or internal standards, and a 10,000-fold lower titre preparation to serve as an in-run control. The preparations have been freeze-dried to maximise stability. These HIV-Ebola virus RNA reference materials were suitable for use with in-house and commercial quantitative RT-PCR assays and with digital RT-PCR. The HIV-Ebola virus RNA reference materials are stable at up to 37°C for two weeks, allowing the shipment of the material worldwide at ambient temperature. These results support further evaluation of the HIV-Ebola virus RNA reference materials as part of an International collaborative study for the establishment of the 1st International Standard for Ebola virus RNA.

  20. Development of potential candidate reference materials for drugs in bottom sediment, cod and herring tissues.

    PubMed

    Baranowska, Irena; Buszewski, Bogusław; Namieśnik, Jacek; Konieczka, Piotr; Magiera, Sylwia; Polkowska-Motrenko, Halina; Kościelniak, Paweł; Gadzała-Kopciuch, Renata; Woźniakiewicz, Aneta; Samczyński, Zbigniew; Kochańska, Kinga; Rutkowska, Małgorzata

    2017-02-01

    Regular use of a reference material and participation in a proficiency testing program can improve the reliability of analytical data. This paper presents the preparation of candidate reference materials for the drugs metoprolol, propranolol, carbamazepine, naproxen, and acenocoumarol in freshwater bottom sediment and cod and herring tissues. These reference materials are not available commercially. Drugs (between 7 ng/g and 32 ng/g) were added to the samples, and the spiked samples were freeze-dried, pulverized, sieved, homogenized, bottled, and sterilized by γ-irradiation to prepare the candidate materials. Procedures for extraction and liquid chromatography coupled with tandem mass spectrometry were developed to determine the drugs of interest in the studied material. Each target drug was quantified using two analytical procedures, and the results obtained from these two procedures were in good agreement with each other. Stability and homogeneity assessments were performed, and the relative uncertainties due to instability (for an expiration date of 12 months) and inhomogeneity were 10-25% and 4.0-6.8%, respectively. These procedures will be useful in the future production of reference materials. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Automated Coastal Engineering System: Technical Reference

    DTIC Science & Technology

    1992-09-01

    of Contents ACES Technical Reference Wave Transmission Through Permeable Structures ..................................... 5-4 Littoral Processes...A-2 Table A-4: Grain-Size Scales ( Soil Classification) ..................................... A-3 Table A-5: Major Tidal Constituents... Permeable Structures Lonphore Sediment Tranaport Littoral Numerical Si~ulation of Time-Dependent Beach and Dune Erosion Processes Calculation of Composite

  2. Characterization of Ricin and R. communis Agglutinin Reference Materials

    PubMed Central

    Worbs, Sylvia; Skiba, Martin; Söderström, Martin; Rapinoja, Marja-Leena; Zeleny, Reinhard; Russmann, Heiko; Schimmel, Heinz; Vanninen, Paula; Fredriksson, Sten-Åke; Dorner, Brigitte G.

    2015-01-01

    Ricinus communis intoxications have been known for centuries and were attributed to the toxic protein ricin. Due to its toxicity, availability, ease of preparation, and the lack of medical countermeasures, ricin attracted interest as a potential biological warfare agent. While different technologies for ricin analysis have been established, hardly any universally agreed-upon “gold standards” are available. Expert laboratories currently use differently purified in-house materials, making any comparison of accuracy and sensitivity of different methods nearly impossible. Technically challenging is the discrimination of ricin from R. communis agglutinin (RCA120), a less toxic but highly homologous protein also contained in R. communis. Here, we established both highly pure ricin and RCA120 reference materials which were extensively characterized by gel electrophoresis, liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI MS/MS), and matrix-assisted laser desorption ionization–time of flight approaches as well as immunological and functional techniques. Purity reached >97% for ricin and >99% for RCA120. Different isoforms of ricin and RCA120 were identified unambiguously and distinguished by LC-ESI MS/MS. In terms of function, a real-time cytotoxicity assay showed that ricin is approximately 300-fold more toxic than RCA120. The highly pure ricin and RCA120 reference materials were used to conduct an international proficiency test. PMID:26703723

  3. Preparation of reference material for UGT1A1 (TA)n polymorphism genotyping.

    PubMed

    Mlakar, Vid; Mlakar, Simona Jurković; Marc, Janja; Ostanek, Barbara

    2014-08-05

    Gilbert's syndrome is one of the most common metabolic syndromes in the human population characterised by mild unconjugated hyperbilirubinemia resulting from reduced activity of the bilirubin conjugating enzyme UDP-glucuronosyltransferase (UGT1A1). Although Gilbert's syndrome is usually quite benign UGT1A1(TA)n genotyping is important in exclusion of more serious causes of hyperbilirubinemia and since it has significant implications for personalised medicine. The aim of our study was to develop plasmid based reference materials which could be used for UGT1A1(TA)n genotyping. Plasmids were generated using recombinant DNA technology and their number of repeats as well as the entire sequence verified by Sanger sequencing. Their suitability as reference materials was tested using sizing by capillary electrophoresis and denaturing high performance liquid chromatography. Plasmids containing all four different alleles (TA)5, (TA)6, (TA)7 and (TA)8 that are present in the human population as well as a plasmid with (TA)4 repeats were successfully generated. Prepared plasmid reference materials allow the creation of all possible UGT1A1(TA)n polymorphism genotypes and can serve as an efficient substitute for the human genomic DNA reference material in routine genotyping and in the development of new genotyping tests. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Real-time sonoelastography using an external reference material: test-retest reliability of healthy Achilles tendons.

    PubMed

    Schneebeli, Alessandro; Del Grande, Filippo; Vincenzo, Gabriele; Cescon, Corrado; Clijsen, Ron; Biordi, Fulvio; Barbero, Marco

    2016-08-01

    To establish the test-retest reliability of sonoelastography (SE) on healthy Achilles tendons in contracted and relaxed states using an external reference system. Forty-eight Achilles tendons from 24 healthy volunteers were assessed using ultrasound and real-time SE with an external reference material. Tendons were analyzed under relaxed and contracted conditions. Strain ratios between the tendons and the reference material were calculated. The intraclass correlation coefficient (ICC2.k) and Bland-Altman plot were used to assess test-retest reliability. The reliability of SE measurements under relaxed conditions ranged from high to very high, with an ICC2.k of 0.84 (95 % CI: 0.64-0.92) for reference material, 0.91 (95 % CI: 0.83-0.95) for Achilles tendons and 0.95 (95 % CI: 0.91-0.97) for Kager fat pads (KFP). The ICC2.k value for skin was 0.30 (95 % CI: -0.26 to 0.61). Reliability for measurements in the contracted state ranged from high to very high, with an ICC2.k of 0.93 (95 % CI: 0.87-0.96) for reference material, 0.72 (95 % CI: 0.50-0.84) for skin, 0.93 (95 % CI: 0.87-0.96) for Achilles tendons, and 0.81 (95 % CI: 0.66-0.89) for KFP. Reliability of the strain ratio (tendon/reference) under relaxed conditions was high with an ICC2.k of 0.87 (95 % CI: 0.75-0.93), and in the contracted state, it was very high with an ICC2.k of 0.94 (95 % CI: 0.90-0.97). Sonoelastography using an external reference material is a reliable and simple technique for the assessment of the elasticity of healthy Achilles tendons. The use of an external material as a reference, along with strain ratios, could provide a quantitative measure of elasticity.

  5. Reference materials and representative test materials to develop nanoparticle characterization methods: the NanoChOp project case

    NASA Astrophysics Data System (ADS)

    Roebben, Gert; Kestens, Vikram; Varga, Zoltan; Charoud-Got, Jean; Ramaye, Yannic; Gollwitzer, Christian; Bartczak, Dorota; Geißler, Daniel; Noble, James; Mazoua, Stéphane; Meeus, Nele; Corbisier, Philippe; Palmai, Marcell; Mihály, Judith; Krumrey, Michael; Davies, Julie; Resch-Genger, Ute; Kumarswami, Neelam; Minelli, Caterina; Sikora, Aneta; Goenaga-Infante, Heidi

    2015-10-01

    This paper describes the production and characteristics of the nanoparticle test materials prepared for common use in the collaborative research project NanoChOp (Chemical and optical characterisation of nanomaterials in biological systems), in casu suspensions of silica nanoparticles and CdSe/CdS/ZnS quantum dots. This paper is the first to illustrate how to assess whether nanoparticle test materials meet the requirements of a 'reference material' (ISO Guide 30:2015) or rather those of the recently defined category of 'representative test material' (ISO TS 16195:2013). The NanoChOp test materials were investigated with small-angle X-ray scattering (SAXS), dynamic light scattering (DLS) and centrifugal liquid sedimentation (CLS) to establish whether they complied with the required monomodal particle size distribution. The presence of impurities, aggregates, agglomerates and viable microorganisms in the suspensions was investigated with DLS, CLS, optical and electron microscopy and via plating on nutrient agar. Suitability of surface functionalization was investigated with attenuated total reflection Fourier transform infrared spectrometry (ATR-FTIR) and via the capacity of the nanoparticles to be fluorescently labeled or to bind antibodies. Between-unit homogeneity and stability were investigated in terms of particle size and zeta potential. This paper shows that only based on the outcome of a detailed characterization process one can raise the status of a test material to representative test material or reference material, and how this status depends on its intended use.

  6. 40 CFR Table C-2 to Subpart C of... - Sequence of Test Measurements

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Sequence of Test Measurements C Table C-2 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Comparability Between Candidate Methods and Reference Methods Pt. 53, Subpt. C, Table C-2 Table C-2 to Subpart C...

  7. 40 CFR Table C-2 to Subpart C of... - Sequence of Test Measurements

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Sequence of Test Measurements C Table C-2 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Comparability Between Candidate Methods and Reference Methods Pt. 53, Subpt. C, Table C-2 Table C-2 to Subpart C...

  8. 40 CFR Table C-2 to Subpart C of... - Sequence of Test Measurements

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Sequence of Test Measurements C Table C-2 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Comparability Between Candidate Methods and Reference Methods Pt. 53, Subpt. C, Table C-2 Table C-2 to Subpart C...

  9. 40 CFR Table C-2 to Subpart C of... - Sequence of Test Measurements

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Sequence of Test Measurements C Table C-2 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Comparability Between Candidate Methods and Reference Methods Pt. 53, Subpt. C, Table C-2 Table C-2 to Subpart C...

  10. 40 CFR Table C-2 to Subpart C of... - Sequence of Test Measurements

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Sequence of Test Measurements C Table C-2 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Comparability Between Candidate Methods and Reference Methods Pt. 53, Subpt. C, Table C-2 Table C-2 to Subpart C...

  11. Interaction of Learner Characteristics with Learning from Three Models of the Periodic Table.

    ERIC Educational Resources Information Center

    Lehman, Jeffrey R.; And Others

    1984-01-01

    Explored the effects of learning on structural modifications to the periodic table; the location of a periodic table within instructional materials; and the presence of a two-page schema showing relationships between the topics explained in the written materials and the periodic table. Results obtained from 160 students are reported and discussed.…

  12. Certified reference materials (GBW09170 and 09171) of creatinine in human serum.

    PubMed

    Dai, Xinhua; Fang, Xiang; Shao, Mingwu; Li, Ming; Huang, Zejian; Li, Hongmei; Jiang, You; Song, Dewei; He, Yajuan

    2011-02-15

    Creatinine is the most widely used clinical marker for assessing renal function. Concentrations of creatinine in human serum need to be carefully checked in order to ensure accurate diagnosis of renal function. Therefore, development of certified reference materials (CRMs) of creatinine in serum is of increasing importance. In this study, two new CRMs (Nos. GBW09170 and 09171) for creatinine in human serum have been developed. They were prepared with mixtures of several dozens of healthy people's and kidney disease patient's serum, respectively. The certified values of 8.10, 34.1 mg/kg for these two CRMs have been assigned by liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) method which was validated by using standard reference material (SRM) of SRM909b (a reference material obtained from National Institute of Standards and Technology, NIST). The expanded uncertainties of certified values for low and high concentrations were estimated to be 1.2 and 1.1%, respectively. The certified values were further confirmed by an international intercomparison for the determination of creatinine in human serum (Consultative Committee for Amount of Substance, CCQM) of K80 (CCQM-K80). These new CRMs of creatinine in human serum pool are totally native without additional creatinine spiked for enrichment. These new CRMs are capable of validating routine clinical methods for ensuring accuracy, reliability and comparability of analytical results from different clinical laboratories. They can also be used for instrument validation, development of secondary reference materials, and evaluating the accuracy of high order clinical methods for the determination of creatinine in human serum. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. 2003 Oregon state highway accident rate tables

    DOT National Transportation Integrated Search

    2005-01-01

    The three major sections of this publication are: : I Results of Analysis - containing comparative tables and cross-reference : lists of highways by number, name and route; : II Highway crash rates for the last five years; and : III Summaries of this...

  14. Development and Characterization of Reference Materials for Genetic Testing: Focus on Public Partnerships.

    PubMed

    Kalman, Lisa V; Datta, Vivekananda; Williams, Mickey; Zook, Justin M; Salit, Marc L; Han, Jin Yeong

    2016-11-01

    Characterized reference materials (RMs) are needed for clinical laboratory test development and validation, quality control procedures, and proficiency testing to assure their quality. In this article, we review the development and characterization of RMs for clinical molecular genetic tests. We describe various types of RMs and how to access and utilize them, especially focusing on the Genetic Testing Reference Materials Coordination Program (Get-RM) and the Genome in a Bottle (GIAB) Consortium. This review also reinforces the need for collaborative efforts in the clinical genetic testing community to develop additional RMs.

  15. Development of NIST standard reference material 2373: Genomic DNA standards for HER2 measurements.

    PubMed

    He, Hua-Jun; Almeida, Jamie L; Lund, Steve P; Steffen, Carolyn R; Choquette, Steve; Cole, Kenneth D

    2016-06-01

    NIST standard reference material (SRM) 2373 was developed to improve the measurements of the HER2 gene amplification in DNA samples. SRM 2373 consists of genomic DNA extracted from five breast cancer cell lines with different amounts of amplification of the HER2 gene. The five components are derived from the human cell lines SK-BR-3, MDA-MB-231, MDA-MB-361, MDA-MB-453, and BT-474. The certified values are the ratios of the HER2 gene copy numbers to the copy numbers of selected reference genes DCK, EIF5B, RPS27A, and PMM1. The ratios were measured using quantitative polymerase chain reaction and digital PCR, methods that gave similar ratios. The five components of SRM 2373 have certified HER2 amplification ratios that range from 1.3 to 17.7. The stability and homogeneity of the reference materials were shown by repeated measurements over a period of several years. SRM 2373 is a well characterized genomic DNA reference material that can be used to improve the confidence of the measurements of HER2 gene copy number.

  16. A Development Strategy for Creating a Suite of Reference Materials for the in-situ Microanalysis of Non-conventional Raw Materials

    NASA Astrophysics Data System (ADS)

    Renno, A. D.; Merchel, S.; Michalak, P. P.; Munnik, F.; Wiedenbeck, M.

    2010-12-01

    Recent economic trends regarding the supply of rare metals readily justify scientific research into non-conventional raw materials, where a particular need is a better understanding of the relationship between mineralogy, microstructure and the distribution of key metals within ore deposits (geometallurgy). Achieving these goals will require an extensive usage of in-situ microanalytical techniques capable of spatially resolving material heterogeneities which can be key for understanding better resource utilization. The availability of certified reference materials (CRMs) is an essential prerequisite for (1) validating new analytical methods, (2) demonstrating data quality to the contracting authorities, (3) supporting method development and instrument calibration, and (4) establishing traceability between new analytical approaches and existing data sets. This need has led to the granting of funding by the European Union and the German Free State of Saxony for a program to develop such reference materials . This effort will apply the following strategies during the selection of the phases: (1) will use exclusively synthetic minerals, thereby providing large volumes of homogeneous starting material. (2) will focus on matrices which are capable of incorporating many ‘important’ elements while avoid exotic compositions which would not be optimal matrix matches. (3) will emphasise those phases which remain stable during the various microanalytical procedure. This initiative will assess the homogeneity of the reference materials at sampling sizes ranging between 50 and 1 µm; it is also intended to document crystal structural homogeneity too, as this too may potentially impact specific analytical methods. As far as possible both definitive methods as well as methods involving matrix corrections will be used for determining the compositions of the of the individual materials. A critical challenge will be the validation of the determination of analytes concentrations

  17. 40 CFR Table 1 to Subpart W of... - General Provisions Applicability to Subpart W

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart W 1 Table 1 to Subpart W of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Polyamides Production Pt. 63, Subpt. W, Table 1 Table 1 to Subpart W of Part 63—General Provisions Applicability to Subpart W Reference Applies to subpart W BLR WSR WSR alternative standard, and BLR equipment...

  18. Problem Posing with the Multiplication Table

    ERIC Educational Resources Information Center

    Dickman, Benjamin

    2014-01-01

    Mathematical problem posing is an important skill for teachers of mathematics, and relates readily to mathematical creativity. This article gives a bit of background information on mathematical problem posing, lists further references to connect problem posing and creativity, and then provides 20 problems based on the multiplication table to be…

  19. Analysis of street drugs in seized material without primary reference standards.

    PubMed

    Laks, Suvi; Pelander, Anna; Vuori, Erkki; Ali-Tolppa, Elisa; Sippola, Erkki; Ojanperä, Ilkka

    2004-12-15

    A novel approach was used to analyze street drugs in seized material without primary reference standards. Identification was performed by liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS), essentially based on accurate mass determination using a target library of 735 exact monoisotopic masses. Quantification was carried out by liquid chromatography/chemiluminescence nitrogen detection (LC/CLND) with a single secondary standard (caffeine), utilizing the detector's equimolar response to nitrogen. Sample preparation comprised dilution, first with methanol and further with the LC mobile phase. Altogether 21 seized drug samples were analyzed blind by the present method, and results were compared to accredited reference methods utilizing identification by gas chromatography/mass spectrometry and quantification by gas chromatography or liquid chromatography. The 31 drug findings by LC/TOFMS comprised 19 different drugs-of-abuse, byproducts, and adulterants, including amphetamine and tryptamine designer drugs, with one unresolved pair of compounds having an identical mass. By the reference methods, 27 findings could be confirmed, and among the four unconfirmed findings, only 1 apparent false positive was found. In the quantitative analysis of 11 amphetamine, heroin, and cocaine findings, mean relative difference between the results of LC/CLND and the reference methods was 11% (range 4.2-21%), without any observable bias. Mean relative standard deviation for three parallel LC/CLND results was 6%. Results suggest that the present combination of LC/TOFMS and LC/CLND offers a simple solution for the analysis of scheduled and designer drugs in seized material, independent of the availability of primary reference standards.

  20. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets.

    PubMed

    Turk, Gregory C; Sharpless, Katherine E; Cleveland, Danielle; Jongsma, Candice; Mackey, Elizabeth A; Marlow, Anthony F; Oflaz, Rabia; Paul, Rick L; Sieber, John R; Thompson, Robert Q; Wood, Laura J; Yu, Lee L; Zeisler, Rolf; Wise, Stephen A; Yen, James H; Christopher, Steven J; Day, Russell D; Long, Stephen E; Greene, Ella; Harnly, James; Ho, I-Pin; Betz, Joseph M

    2013-01-01

    Standard Reference Material 3280 Multivitamin/ Multielement Tablets was issued by the National Institute of Standards and Technology in 2009, and has certified and reference mass fraction values for 13 vitamins, 26 elements, and two carotenoids. Elements were measured using two or more analytical methods at NIST with additional data contributed by collaborating laboratories. This reference material is expected to serve a dual purpose: to provide quality assurance in support of a database of dietary supplement products and to provide a means for analysts, dietary supplement manufacturers, and researchers to assess the appropriateness and validity of their analytical methods and the accuracy of their results.

  1. Evaluation of droplet digital PCR for characterizing plasmid reference material used for quantifying ammonia oxidizers and denitrifiers.

    PubMed

    Dong, Lianhua; Meng, Ying; Wang, Jing; Liu, Yingying

    2014-02-01

    DNA reference materials of certified value have a critical function in many analytical processes of DNA measurement. Quantification of amoA genes in ammonia oxidizing bacteria (AOB) and archaea (AOA), and of nirS and nosZ genes in the denitrifiers is very important for determining their distribution and abundance in the natural environment. A plasmid reference material containing nirS, nosZ, amoA-AOB, and amoA-AOA is developed to provide a DNA standard with copy number concentration for ensuring comparability and reliability of quantification of these genes. Droplet digital PCR (ddPCR) was evaluated for characterization of the plasmid reference material. The result revealed that restriction endonuclease digestion of plasmids can improve amplification efficiency and minimize the measurement bias of ddPCR. Compared with the conformation of the plasmid, the size of the DNA fragment containing the target sequence and the location of the restriction site relative to the target sequence are not significant factors affecting plasmid quantification by ddPCR. Liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) was used to provide independent data for quantifying the plasmid reference material. The copy number concentration of the digested plasmid determined by ddPCR agreed well with that determined by LC-IDMS, improving both the accuracy and reliability of the plasmid reference material. The reference value, with its expanded uncertainty (k = 2), of the plasmid reference material was determined to be (5.19 ± 0.41) × 10(9) copies μL(-1) by averaging the results of two independent measurements. Consideration of the factors revealed in this study can improve the reliability and accuracy of ddPCR; thus, this method has the potential to accurately quantify DNA reference materials.

  2. 40 CFR Table 1 to Subpart S of... - General Provisions Applicability to Subpart S a

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart S a 1 Table 1 to Subpart S of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY..., Subpt. S, Table 1 Table 1 to Subpart S of Part 63—General Provisions Applicability to Subpart S a Reference Applies to Subpart S Comment 63.1(a)(1)-(3) Yes 63.1(a)(4) Yes Subpart S (this table) specifies...

  3. Determination of perfluorinated alkyl acid concentrations in biological standard reference materials.

    PubMed

    Reiner, Jessica L; O'Connell, Steven G; Butt, Craig M; Mabury, Scott A; Small, Jeff M; De Silva, Amila O; Muir, Derek C G; Delinsky, Amy D; Strynar, Mark J; Lindstrom, Andrew B; Reagen, William K; Malinsky, Michelle; Schäfer, Sandra; Kwadijk, Christiaan J A F; Schantz, Michele M; Keller, Jennifer M

    2012-11-01

    Standard reference materials (SRMs) are homogeneous, well-characterized materials used to validate measurements and improve the quality of analytical data. The National Institute of Standards and Technology (NIST) has a wide range of SRMs that have mass fraction values assigned for legacy pollutants. These SRMs can also serve as test materials for method development, method validation, and measurement for contaminants of emerging concern. Because inter-laboratory comparison studies have revealed substantial variability of measurements of perfluoroalkyl acids (PFAAs), future analytical measurements will benefit from determination of consensus values for PFAAs in SRMs to provide a means to demonstrate method-specific performance. To that end, NIST, in collaboration with other groups, has been measuring concentrations of PFAAs in a variety of SRMs. Here we report levels of PFAAs and perfluorooctane sulfonamide (PFOSA) determined in four biological SRMs: fish tissue (SRM 1946 Lake Superior Fish Tissue, SRM 1947 Lake Michigan Fish Tissue), bovine liver (SRM 1577c), and mussel tissue (SRM 2974a). We also report concentrations for three in-house quality-control materials: beluga whale liver, pygmy sperm whale liver, and white-sided dolphin liver. Measurements in SRMs show an array of PFAAs, with perfluorooctane sulfonate (PFOS) being the most frequently detected. Reference and information values are reported for PFAAs measured in these biological SRMs.

  4. The NIH analytical methods and reference materials program for dietary supplements.

    PubMed

    Betz, Joseph M; Fisher, Kenneth D; Saldanha, Leila G; Coates, Paul M

    2007-09-01

    Quality of botanical products is a great uncertainty that consumers, clinicians, regulators, and researchers face. Definitions of quality abound, and include specifications for sanitation, adventitious agents (pesticides, metals, weeds), and content of natural chemicals. Because dietary supplements (DS) are often complex mixtures, they pose analytical challenges and method validation may be difficult. In response to product quality concerns and the need for validated and publicly available methods for DS analysis, the US Congress directed the Office of Dietary Supplements (ODS) at the National Institutes of Health (NIH) to accelerate an ongoing methods validation process, and the Dietary Supplements Methods and Reference Materials Program was created. The program was constructed from stakeholder input and incorporates several federal procurement and granting mechanisms in a coordinated and interlocking framework. The framework facilitates validation of analytical methods, analytical standards, and reference materials.

  5. Online Periodic Table: A Cautionary Note

    NASA Astrophysics Data System (ADS)

    Izci, Kemal; Barrow, Lloyd H.; Thornhill, Erica

    2013-08-01

    The purpose of this study was (a) to evaluate ten online periodic table sources for their accuracy and (b) to compare the types of information and links provided to users. Limited studies have been reported on online periodic table (Diener and Moore 2011; Slocum and Moore in J Chem Educ 86(10):1167, 2009). Chemistry students' understanding of periodic table is vital for their success in chemistry, and the online periodic table has the potential to advance learners' understanding of chemical elements and fundamental chemistry concepts (Brito et al. in J Res Sci Teach 42(1):84-111, 2005). The ten sites were compared for accuracy of data with the Handbook of Chemistry and Physics (HCP, Haynes in CRC handbook of chemistry and physics: a ready-reference book of chemical and physical data. CRC Press, Boca Raton 2012). The 10 sites are the most visited periodic table Web sites available. Four different elements, carbon, gold, argon, and plutonium, were selected for comparison, and 11 different attributes for each element were identified for evaluating accuracy. A wide variation of accuracy was found among the 10 periodic table sources. Chemicool was the most accurate information provider with 66.67 % accuracy when compared to the HCP. The 22 types of information including meaning of name and use in industry and society provided by these sites were, also, compared. WebElements, "Chemicool", "Periodic Table Live", and "the Photographic Periodic Table of the Elements" were the most information providers, providing 86.36 % of information among the 10 Web sites. "WebElements" provides the most links among the 10 Web sites. It was concluded that if an individual teacher or student desires only raw physical data from element, the Internet might not be the best choice.

  6. 40 CFR Table 1 to Subpart Jj of... - General Provisions Applicability to Subpart JJ

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart JJ 1 Table 1 to Subpart JJ of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY.... JJ, Table 1 Table 1 to Subpart JJ of Part 63—General Provisions Applicability to Subpart JJ Reference Applies to subpart JJ Comment 63.1(a) Yes 63.1(b)(1) No Subpart JJ specifies applicability. 63.1(b)(2) Yes...

  7. On the traceability of gaseous reference materials

    NASA Astrophysics Data System (ADS)

    Brown, Richard J. C.; Brewer, Paul J.; Harris, Peter M.; Davidson, Stuart; van der Veen, Adriaan M. H.; Ent, Hugo

    2017-06-01

    The complex and multi-parameter nature of chemical composition measurement means that establishing traceability is a challenging task. As a result incorrect interpretations about the origin of the metrological traceability of chemical measurement results can occur. This discussion paper examines why this is the case by scrutinising the peculiarities of the gas metrology area. It considers in particular: primary methods, dissemination of metrological traceability and the role of documentary standards and accreditation bodies in promulgating best practice. There is also a discussion of documentary standards relevant to the NMI and reference material producer community which need clarification, and the impact which key stakeholders in the quality infrastructure can bring to these issues.

  8. Reference-material system for estimating health and environmental risks of selected material cycles and energy systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crowther, M.A.; Moskowitz, P.D.

    1981-07-01

    Sample analyses and detailed documentation are presented for a Reference Material System (RMS) to estimate health and environmental risks of different material cycles and energy systems. Data inputs described include: end-use material demands, efficiency coefficients, environmental emission coefficients, fuel demand coefficients, labor productivity estimates, and occupational health and safety coefficients. Application of this model permits analysts to estimate fuel use (e.g., Btu), occupational risk (e.g., fatalities), and environmental emissions (e.g., sulfur oxide) for specific material trajectories or complete energy systems. Model uncertainty is quantitatively defined by presenting a range of estimates for each data input. Systematic uncertainty not quantified relatesmore » to the boundaries chosen for analysis and reference system specification. Although the RMS can be used to analyze material system impacts for many different energy technologies, it was specifically used to examine the health and environmental risks of producing the following four types of photovoltaic devices: silicon n/p single-crystal cells produced by a Czochralski process; silicon metal/insulator/semiconductor (MIS) cells produced by a ribbon-growing process; cadmium sulfide/copper sulfide backwall cells produced by a spray deposition process; and gallium arsenide cells with 500X concentrator produced by a modified Czochralski process. Emission coefficients for particulates, sulfur dioxide and nitrogen dioxide; solid waste; total suspended solids in water; and, where applicable, air and solid waste residuals for arsenic, cadmium, gallium, and silicon are examined and presented. Where data are available the coefficients for particulates, sulfur oxides, and nitrogen oxides include both process and on-site fuel-burning emissions.« less

  9. The Pythagorean table of opposites, symbolic classification, and Aristotle.

    PubMed

    Goldin, Owen

    2015-06-01

    At Metaphysics A 5 986a22-b2, Aristotle refers to a Pythagorean table, with two columns of paired opposites. I argue that 1) although Burkert and Zhmud have argued otherwise, there is sufficient textual evidence to indicate that the table, or one much like it, is indeed of Pythagorean origin; 2) research in structural anthropology indicates that the tables are a formalization of arrays of "symbolic classification" which express a pre-scientific world view with social and ethical implications, according to which the presence of a principle on one column of the table will carry with it another principle within the same column; 3) a close analysis of Aristotle's arguments shows that he thought that the table expresses real causal relationships; and 4) Aristotle faults the table of opposites with positing its principles as having universal application and with not distinguishing between those principles that are causally prior and those that are posterior. Aristotle's account of scientific explanation and his own explanations that he developed in accordance with this account are in part the result of his critical encounter with this prescientific Pythagorean table.

  10. 30 CFR 285.115 - Documents incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... incorporating by reference the documents listed in the table in paragraph (e) of this section. The Director of...: ER29AP09.104 (e) This paragraph lists documents incorporated by reference. To easily reference text of the... 30 Mineral Resources 2 2011-07-01 2011-07-01 false Documents incorporated by reference. 285.115...

  11. Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry-recommended reference measurement procedure and reference materials for glycated albumin determination.

    PubMed

    Takei, Izumi; Hoshino, Tadao; Tominaga, Makoto; Ishibashi, Midori; Kuwa, Katsuhiko; Umemoto, Masao; Tani, Wataru; Okahashi, Mikiko; Yasukawa, Keiko; Kohzuma, Takuji; Sato, Asako

    2016-01-01

    Glycated albumin is an intermediate glycaemic control marker for which there are several measurement procedures with entirely different reference intervals. We have developed a reference measurement procedure for the purpose of standardizing glycated albumin measurements. The isotope dilution liquid chromatography/tandem mass spectrometry method was developed as a reference measurement procedure for glycated albumin. The stable isotopes of lysine and fructosyl-lysine, which serve as an internal standard, were added to albumin isolated from serum, followed by hydrogenation. After hydrolysis of albumin with hot hydrochloric acid, the liberated lysine and fructosyl-lysine were measured by liquid chromatography/tandem mass spectrometry, and their concentrations were determined from each isotope ratio. The reference materials (JCCRM611) for determining of glycated albumin were prepared from pooled patient blood samples. The isotope dilution-tandem mass spectrometry calibration curve of fructosyl-lysine and lysine showed good linearity (r = 0.999). The inter-assay and intra-assay coefficient of variation values of glycated albumin measurement were 1.2 and 1.4%, respectively. The glycated albumin values of serum in patients with diabetes assessed through the use of this method showed a good relationship with routine measurement procedures (r = 0.997). The relationship of glycated albumin values of the reference material (JCCRM611) between these two methods was the same as the relationship with the patient serum samples. The Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry recommends the isotope dilution liquid chromatography/tandem mass spectrometry method as a reference measurement procedure, and JCCRM611 as a certified reference material for glycated albumin measurement. In addition, we recommend the traceability system for glycated albumin measurement. © The Author(s) 2015.

  12. Characterization of a Recombinant Adeno-Associated Virus Type 2 Reference Standard Material

    PubMed Central

    Lock, Martin; McGorray, Susan; Auricchio, Alberto; Ayuso, Eduard; Beecham, E. Jeffrey; Blouin-Tavel, Véronique; Bosch, Fatima; Bose, Mahuya; Byrne, Barry J.; Caton, Tina; Chiorini, John A.; Chtarto, Abdelwahed; Clark, K. Reed; Conlon, Thomas; Darmon, Christophe; Doria, Monica; Douar, Anne; Flotte, Terence R.; Francis, Joyce D.; Francois, Achille; Giacca, Mauro; Korn, Michael T.; Korytov, Irina; Leon, Xavier; Leuchs, Barbara; Lux, Gabriele; Melas, Catherine; Mizukami, Hiroaki; Moullier, Philippe; Müller, Marcus; Ozawa, Keiya; Philipsberg, Tina; Poulard, Karine; Raupp, Christina; Rivière, Christel; Roosendaal, Sigrid D.; Samulski, R. Jude; Soltys, Steven M.; Surosky, Richard; Tenenbaum, Liliane; Thomas, Darby L.; van Montfort, Bart; Veres, Gabor; Wright, J. Fraser; Xu, Yili; Zelenaia, Olga; Zentilin, Lorena

    2010-01-01

    Abstract A recombinant adeno-associated virus serotype 2 Reference Standard Material (rAAV2 RSM) has been produced and characterized with the purpose of providing a reference standard for particle titer, vector genome titer, and infectious titer for AAV2 gene transfer vectors. Production and purification of the reference material were carried out by helper virus–free transient transfection and chromatographic purification. The purified bulk material was vialed, confirmed negative for microbial contamination, and then distributed for characterization along with standard assay protocols and assay reagents to 16 laboratories worldwide. Using statistical transformation and modeling of the raw data, mean titers and confidence intervals were determined for capsid particles ({X}, 9.18 × 1011 particles/ml; 95% confidence interval [CI], 7.89 × 1011 to 1.05 × 1012 particles/ml), vector genomes ({X}, 3.28 × 1010 vector genomes/ml; 95% CI, 2.70 × 1010 to 4.75 × 1010 vector genomes/ml), transducing units ({X}, 5.09 × 108 transducing units/ml; 95% CI, 2.00 × 108 to 9.60 × 108 transducing units/ml), and infectious units ({X}, 4.37 × 109 TCID50 IU/ml; 95% CI, 2.06 × 109 to 9.26 × 109 TCID50 IU/ml). Further analysis confirmed the identity of the reference material as AAV2 and the purity relative to nonvector proteins as greater than 94%. One obvious trend in the quantitative data was the degree of variation between institutions for each assay despite the relatively tight correlation of assay results within an institution. This relatively poor degree of interlaboratory precision and accuracy was apparent even though attempts were made to standardize the assays by providing detailed protocols and common reagents. This is the first time that such variation between laboratories has been thoroughly documented and the findings emphasize the need in the field for universal reference standards. The rAAV2 RSM has been deposited

  13. The NISTmAb Reference Material 8671 lifecycle management and quality plan.

    PubMed

    Schiel, John E; Turner, Abigail

    2018-03-01

    Comprehensive analysis of monoclonal antibody therapeutics involves an ever expanding cadre of technologies. Lifecycle-appropriate application of current and emerging techniques requires rigorous testing followed by discussion between industry and regulators in a pre-competitive space, an effort that may be facilitated by a widely available test metric. Biopharmaceutical quality materials, however, are often difficult to access and/or are protected by intellectual property rights. The NISTmAb, humanized IgG1κ Reference Material 8671 (RM 8671), has been established with the intent of filling that void. The NISTmAb embodies the quality and characteristics of a typical biopharmaceutical product, is widely available to the biopharmaceutical community, and is an open innovation tool for development and dissemination of results. The NISTmAb lifecyle management plan described herein provides a hierarchical strategy for maintenance of quality over time through rigorous method qualification detailed in additional submissions in the current publication series. The NISTmAb RM 8671 is a representative monoclonal antibody material and provides a means to continually evaluate current best practices, promote innovative approaches, and inform regulatory paradigms as technology advances. Graphical abstract The NISTmAb Reference Material (RM) 8671 is intended to be an industry standard monoclonal antibody for pre-competitive harmonization of best practices and designing next generation characterization technologies for identity, quality, and stability testing.

  14. 40 CFR Table 1 to Subpart R of... - General Provisions Applicability to Subpart R

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Subpart R 1 Table 1 to Subpart R of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Pipeline Breakout Stations) Pt. 63, Subpt. R, Table 1 Table 1 to Subpart R of Part 63—General Provisions Applicability to Subpart R Reference Applies to subpart R Comment 63.1(a)(1) Yes 63.1(a)(2) Yes 63.1(a)(3) Yes...

  15. 40 CFR Table 1 to Subpart R of... - General Provisions Applicability to Subpart R

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Subpart R 1 Table 1 to Subpart R of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Pipeline Breakout Stations) Pt. 63, Subpt. R, Table 1 Table 1 to Subpart R of Part 63—General Provisions Applicability to Subpart R Reference Applies to subpart R Comment 63.1(a)(1) Yes 63.1(a)(2) Yes 63.1(a)(3) Yes...

  16. 40 CFR Table 1 to Subpart R of... - General Provisions Applicability to Subpart R

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Subpart R 1 Table 1 to Subpart R of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Pipeline Breakout Stations) Pt. 63, Subpt. R, Table 1 Table 1 to Subpart R of Part 63—General Provisions Applicability to Subpart R Reference Applies to subpart R Comment 63.1(a)(1) Yes 63.1(a)(2) Yes 63.1(a)(3) Yes...

  17. 40 CFR Table 1 to Subpart R of... - General Provisions Applicability to Subpart R

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart R 1 Table 1 to Subpart R of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Pipeline Breakout Stations) Pt. 63, Subpt. R, Table 1 Table 1 to Subpart R of Part 63—General Provisions Applicability to Subpart R Reference Applies to subpart R Comment 63.1(a)(1) Yes 63.1(a)(2) Yes 63.1(a)(3) Yes...

  18. 40 CFR Table 1 to Subpart R of... - General Provisions Applicability to Subpart R

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Subpart R 1 Table 1 to Subpart R of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Pipeline Breakout Stations) Pt. 63, Subpt. R, Table 1 Table 1 to Subpart R of Part 63—General Provisions Applicability to Subpart R Reference Applies to subpart R Comment 63.1(a)(1) Yes 63.1(a)(2) Yes 63.1(a)(3) Yes...

  19. 40 CFR Table 1 to Subpart X of... - General Provisions Applicability to Subpart X

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Subpart X 1 Table 1 to Subpart X of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY..., Subpt. X, Table 1 Table 1 to Subpart X of Part 63—General Provisions Applicability to Subpart X Reference Applies to subpart X Comment 63.1 Yes. 63.2 Yes. 63.3 Yes. 63.4 Yes. 63.5 Yes. 63.6(a), (b), (c...

  20. 40 CFR Table 1 to Subpart X of... - General Provisions Applicability to Subpart X

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Subpart X 1 Table 1 to Subpart X of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY..., Subpt. X, Table 1 Table 1 to Subpart X of Part 63—General Provisions Applicability to Subpart X Reference Applies to subpart X Comment 63.1 Yes. 63.2 Yes. 63.3 Yes. 63.4 Yes. 63.5 Yes. 63.6(a), (b), (c...

  1. 40 CFR Table 1 to Subpart X of... - General Provisions Applicability to Subpart X

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Subpart X 1 Table 1 to Subpart X of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY..., Subpt. X, Table 1 Table 1 to Subpart X of Part 63—General Provisions Applicability to Subpart X Reference Applies to subpart X Comment 63.1 Yes. 63.2 Yes. 63.3 Yes. 63.4 Yes. 63.5 Yes. 63.6(a), (b), (c...

  2. Reading Materials in Large Print: A Resource Guide. Reference Circular No. 97-02.

    ERIC Educational Resources Information Center

    Mendle, Gillian, Comp.

    This reference circular contains information about large-print materials. Section 1 is an annotated list of selected sources of large-print materials available for purchase or loan. The sources are publishers or distributors, specialized libraries, and associations for persons with visual impairments. Several of these sources also provide general…

  3. Characterization of Viscoelastic Materials Using Group Shear Wave Speeds.

    PubMed

    Rouze, Ned C; Deng, Yufeng; Trutna, Courtney A; Palmeri, Mark L; Nightingale, Kathryn R

    2018-05-01

    Recent investigations of viscoelastic properties of materials have been performed by observing shear wave propagation following localized, impulsive excitations, and Fourier decomposing the shear wave signal to parameterize the frequency-dependent phase velocity using a material model. This paper describes a new method to characterize viscoelastic materials using group shear wave speeds , , and determined from the shear wave displacement, velocity, and acceleration signals, respectively. Materials are modeled using a two-parameter linear attenuation model with phase velocity and dispersion slope at a reference frequency of 200 Hz. Analytically calculated lookup tables are used to determine the two material parameters from pairs of measured group shear wave speeds. Green's function calculations are used to validate the analytic model. Results are reported for measurements in viscoelastic and approximately elastic phantoms and demonstrate good agreement with phase velocities measured using Fourier analysis of the measured shear wave signals. The calculated lookup tables are relatively insensitive to the excitation configuration. While many commercial shear wave elasticity imaging systems report group shear wave speeds as the measures of material stiffness, this paper demonstrates that differences , , and of group speeds are first-order measures of the viscous properties of materials.

  4. Certification of elements in and use of standard reference material 3280 multivitamin/multielement tablets

    USDA-ARS?s Scientific Manuscript database

    Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets was issued by the National Institute of Standards and Technology (NIST) in 2009 and has certified and reference mass fraction values for 13 vitamins, 26 elements, and 2 carotenoids. Elements were measured using two or more ana...

  5. Electrochemistry of Silicon: Instrumentation, Science, Materials and Applications

    NASA Astrophysics Data System (ADS)

    Lehmann, Volker

    2002-04-01

    Silicon has been and will most probably continue to be the dominant material in semiconductor technology. Although the defect-free silicon single crystal is one of the best understood systems in materails science, its electrochemistry to many people is still a kind of "alchemy". This view is partly due to the interdisciplinary aspects of the topic: Physics meets chemistry at the silicon-electrolyte interface. This book gives a comprehensive overview of this important aspect of silicon technology as well as examples of applications ranging from photonic crystals to biochips. It will serve materials scientists as well as engineers involved in silicon technology as a quick reference with its more than 150 technical tables and diagrams and ca. 1000 references cited for easy access of the original literature.

  6. History of reference materials for food and nutrition metrology: As represented in the series of BERM Symposia

    USDA-ARS?s Scientific Manuscript database

    Establishment of a metrology-based measurement system requires the solid foundation of traceability of measurements to available, appropriate certified reference materials (CRM). In the early 1970s the first “biological” Reference Material (RM) of Bowens Kale, Orchard Leaves, and Bovine Liver from ...

  7. Polyfluorinated substances in abiotic standard reference materials.

    PubMed

    Reiner, Jessica L; Blaine, Andrea C; Higgins, Christopher P; Huset, Carin; Jenkins, Thomas M; Kwadijk, Christiaan J A F; Lange, Cleston C; Muir, Derek C G; Reagen, William K; Rich, Courtney; Small, Jeff M; Strynar, Mark J; Washington, John W; Yoo, Hoon; Keller, Jennifer M

    2015-04-01

    The National Institute of Standards and Technology (NIST) has a wide range of Standard Reference Materials (SRMs) which have values assigned for legacy organic pollutants and toxic elements. Existing SRMs serve as homogenous materials that can be used for method development, method validation, and measurement for contaminants that are now of concern. NIST and multiple groups have been measuring the mass fraction of a group of emerging contaminants, polyfluorinated substances (PFASs), in a variety of SRMs. Here we report levels determined in an interlaboratory comparison of up to 23 PFASs determined in five SRMs: sediment (SRMs 1941b and 1944), house dust (SRM 2585), soil (SRM 2586), and sludge (SRM 2781). Measurements presented show an array of PFASs, with perfluorooctane sulfonate being the most frequently detected. SRMs 1941b, 1944, and 2586 had relatively low concentrations of most PFASs measured while 23 PFASs were at detectable levels in SRM 2585 and most of the PFASs measured were at detectable levels in SRM 2781. The measurements made in this study were used to add values to the Certificates of Analysis for SRMs 2585 and 2781.

  8. Molecularly uniform poly(ethylene glycol) certified reference material

    NASA Astrophysics Data System (ADS)

    Takahashi, Kayori; Matsuyama, Shigetomo; Kinugasa, Shinichi; Ehara, Kensei; Sakurai, Hiromu; Horikawa, Yoshiteru; Kitazawa, Hideaki; Bounoshita, Masao

    2015-02-01

    A certified reference material (CRM) for poly(ethylene glycol) with no distribution in the degree of polymerization was developed. The degree of polymerization of the CRM was accurately determined to be 23. Supercritical fluid chromatography (SFC) was used to separate the molecularly uniform polymer from a standard commercial sample with wide polydispersity in its degree of polymerization. Through the use of a specific fractionation system coupled with SFC, we are able to obtain samples of poly(ethylene glycol) oligomer with exact degrees of polymerization, as required for a CRM produced by the National Metrology Institute of Japan.

  9. Critical outlook and trends for environmental reference materials at the Measurements & Testing Generic Activity (European Commission).

    PubMed

    Quevauviller, P; Bennink, D; Bøwadt, S

    2001-05-01

    It is now well recognised that the quality control (QC) of all types of analyses, including environmental analyses depends on the appropriate use of reference materials. One of the ways to check the accuracy of methods is based on the use of Certified Reference Materials (CRMs), whereas other types of (not certified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g. proficiency testing). The perception of these materials, in particular with respect to their production and use, differs widely according to various perspectives (e.g. RM producers, routine laboratories, researchers). This review discusses some critical aspects of RM use and production for the QC of environmental analyses and describes the new approach followed by the Measurements & Testing Generic Activity (European Commission) to tackle new research and production needs.

  10. Reference Materials for Food and Nutrition Metrology: Past, Present and Future

    USDA-ARS?s Scientific Manuscript database

    Establishment of a metrology-based measurement system requires the solid foundation of traceability of measurements to available, appropriate certified reference materials (CRM). In the early 1970’s the first “biological” RM of Bowens Kale, as well as Orchard Leaves and Bovine Liver SRMs, from the ...

  11. Enantiomer fractions of polychlorinated biphenyls in three selected Standard Reference Materials.

    PubMed

    Morrissey, Joshua A; Bleackley, Derek S; Warner, Nicholas A; Wong, Charles S

    2007-01-01

    The enantiomer composition of six chiral polychlorinated biphenyls (PCBs) were measured in three different certified Standard Reference Materials (SRMs) from the US National Institute of Standards and Technology (NIST): SRM 1946 (Lake Superior fish tissue), SRM 1939a (PCB Congeners in Hudson River Sediment), and SRM 2978 (organic contaminants in mussel tissue--Raritan Bay, New Jersey) to aid in quality assurance/quality control methodologies in the study of chiral pollutants in sediments and biota. Enantiomer fractions (EFs) of PCBs 91, 95, 136, 149, 174, and 183 were measured using a suite of chiral columns by gas chromatography/mass spectrometry. Concentrations of target analytes were in agreement with certified values. Target analyte EFs in reference materials were measured precisely (<2% relative standard deviation), indicating the utility of SRM in quality assurance/control methodologies for analyses of chiral compounds in environmental samples. Measured EFs were also in agreement with previously published analyses of similar samples, indicating that similar enantioselective processes were taking place in these environmental matrices.

  12. A note on scrap in the 1992 U.S. input-output tables

    USGS Publications Warehouse

    Swisko, George M.

    2000-01-01

    Introduction A key concern of industrial ecology and life cycle analysis is the disposal and recycling of scrap. One might conclude that the U.S. input-output tables are appropriate tools for analyzing scrap flows. Duchin, for instance, has suggested using input-output analysis for industrial ecology, indicating that input-output economics can trace the stocks and flows of energy and other materials from extraction through production and consumption to recycling or disposal. Lave and others use input-output tables to design life cycle assessment models for studying product design, materials use, and recycling strategies, even with the knowledge that these tables suffer from a lack of comprehensive and detailed data that may never be resolved. Although input-output tables can offer general guidance about the interdependence of economic and environmental processes, data reporting by industry and the economic concepts underlying these tables pose problems for rigorous material flow examinations. This is especially true for analyzing the output of scrap and scrap flows in the United States and estimating the amount of scrap that can be recycled. To show how data reporting has affected the values of scrap in recent input-output tables, this paper focuses on metal scrap generated in manufacturing. The paper also briefly discusses scrap that is not included in the input-output tables and some economic concepts that limit the analysis of scrap flows.

  13. Copper Oxide Precipitates in NBS Standard Reference Material 482

    PubMed Central

    Windsor, Eric S.; Carlton, Robert A.; Gillen, Greg; Wight, Scott A.; Bright, David S.

    2002-01-01

    Copper oxide has been detected in the copper containing alloys of NBS Standard Reference Material (SRM) 482. This occurrence is significant because it represents heterogeneity within a standard reference material that was certified to be homogeneous on a micrometer scale. Oxide occurs as elliptically to spherically shaped precipitates whose size differs with alloy composition. The largest precipitates occur in the Au20-Cu80 alloy and range in size from submicrometer up to 2 μm in diameter. Precipitates are observed using light microscopy, electron microscopy, and secondary ion mass spectrometry (SIMS). SIMS has demonstrated that the precipitates are present within all the SRM 482 wires that contain copper. Only the pure gold wire is precipitate free. Initial results from the analysis of the Au20-Cu80 alloy indicate that the percentage of precipitates is less than 1 % by area. Electron probe microanalysis (EPMA) of large (2 μm) precipitates in this same alloy indicates that precipitates are detectable by EPMA and that their composition differs significantly from the certified alloy composition. The small size and low percentage of these oxide precipitates minimizes the impact that they have upon the intended use of this standard for electron probe microanalysis. Heterogeneity caused by these oxide precipitates may however preclude the use of this standard for automated EPMA analyses and other microanalysis techniques. PMID:27446759

  14. 40 CFR Table 1 to Subpart Q of... - General Provisions Applicability to Subpart Q

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart Q 1 Table 1 to Subpart Q of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY.... 63, Subpt. Q, Table 1 Table 1 to Subpart Q of Part 63—General Provisions Applicability to Subpart Q Reference Applies to Subpart Q Comment 63.1 Yes 63.2 Yes 63.3 No 63.4 Yes 63.5 No 63.6 (a), (b), (c), and (j...

  15. 40 CFR Table 1 to Subpart Q of... - General Provisions Applicability to Subpart Q

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Subpart Q 1 Table 1 to Subpart Q of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY.... 63, Subpt. Q, Table 1 Table 1 to Subpart Q of Part 63—General Provisions Applicability to Subpart Q Reference Applies to Subpart Q Comment 63.1 Yes 63.2 Yes 63.3 No 63.4 Yes 63.5 No 63.6 (a), (b), (c), and (j...

  16. 40 CFR Table 1 to Subpart Q of... - General Provisions Applicability to Subpart Q

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Subpart Q 1 Table 1 to Subpart Q of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY.... 63, Subpt. Q, Table 1 Table 1 to Subpart Q of Part 63—General Provisions Applicability to Subpart Q Reference Applies to Subpart Q Comment 63.1 Yes 63.2 Yes 63.3 No 63.4 Yes 63.5 No 63.6 (a), (b), (c), and (j...

  17. 40 CFR Table 1 to Subpart Q of... - General Provisions Applicability to Subpart Q

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Subpart Q 1 Table 1 to Subpart Q of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY.... 63, Subpt. Q, Table 1 Table 1 to Subpart Q of Part 63—General Provisions Applicability to Subpart Q Reference Applies to Subpart Q Comment 63.1 Yes 63.2 Yes 63.3 No 63.4 Yes 63.5 No 63.6 (a), (b), (c), and (j...

  18. 40 CFR Table 1 to Subpart Q of... - General Provisions Applicability to Subpart Q

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Subpart Q 1 Table 1 to Subpart Q of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY.... 63, Subpt. Q, Table 1 Table 1 to Subpart Q of Part 63—General Provisions Applicability to Subpart Q Reference Applies to Subpart Q Comment 63.1 Yes 63.2 Yes 63.3 No 63.4 Yes 63.5 No 63.6 (a), (b), (c), and (j...

  19. GROUND WATER ISSUE: NONAQUEOUS PHASE LIQUIDS COMPATIBILITY WITH MATERIALS USED IN WELL CONSTRUCTION, SAMPLING, AND REMEDIATION.

    EPA Science Inventory

    This issue paper provides a comprehensive literature review regarding the compatibility of NAPLs with a wide variety of materials used at hazardous waste sites. A condensed reference table of compatibility data for 207 chemicals and 28 commonly used well construction and sampling...

  20. Aluminium-gold reference material for the k0-standardisation of neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Ingelbrecht, C.; Peetermans, F.; De Corte, F.; De Wispelaere, A.; Vandecasteele, C.; Courtijn, E.; D'Hondt, P.

    1991-05-01

    Gold is an excellent comparator material for the k0-standardisation of neutron activation analysis because of its convenient and well defined nuclear properties. The most suitable form for a reference material is a dilute aluminium-gold alloy, for which the self-shielding effect for neutrons is small. Castings of composition Al-0.1 wt.% Au were prepared by crucible-less levitation melting, which gives close control of ingot composition with minimal contamination of the melt. The alloy composition was checked using induction-coupled plasma source emission spectrometry. The homogeneity of the alloy was measured by neutron activation analysis and a relative standard deviation of the gold content of 0.30% was found (10 mg samples). Metallography revealed a homogeneous distribution of AuAl 2 particles. The alloy was certified as Reference Material CBNM-530, with certified gold mass fraction 0.100±0.002 wt.%.

  1. River bottom sediment from the Vistula as matrix of candidate for a new reference material.

    PubMed

    Kiełbasa, Anna; Buszewski, Bogusław

    2017-08-01

    Bottom sediments are very important in aquatic ecosystems. The sediments accumulate heavy metals and compounds belonging to the group of persistent organic pollutants. The accelerated solvent extraction (ASE) was used for extraction of 16 compounds from PAH group from bottom sediment of Vistula. For the matrix of candidate of a new reference material, moisture content, particle size, loss on ignition, pH, and total organic carbon were determined. A gas chromatograph with a selective mass detector (GC/MS) was used for the final analysis. The obtained recoveries were from 86% (SD=6.9) for anthracene to 119% (SD=5.4) for dibenzo(ah)anthracene. For the candidate for a new reference material, homogeneity and analytes content were determined using a validated method. The results are a very important part of the development and certification of a new reference materials. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. The characterization and certification of a quantitative reference material for Legionella detection and quantification by qPCR.

    PubMed

    Baume, M; Garrelly, L; Facon, J P; Bouton, S; Fraisse, P O; Yardin, C; Reyrolle, M; Jarraud, S

    2013-06-01

    The characterization and certification of a Legionella DNA quantitative reference material as a primary measurement standard for Legionella qPCR. Twelve laboratories participated in a collaborative certification campaign. A candidate reference DNA material was analysed through PCR-based limiting dilution assays (LDAs). The validated data were used to statistically assign both a reference value and an associated uncertainty to the reference material. This LDA method allowed for the direct quantification of the amount of Legionella DNA per tube in genomic units (GU) and the determination of the associated uncertainties. This method could be used for the certification of all types of microbiological standards for qPCR. The use of this primary standard will improve the accuracy of Legionella qPCR measurements and the overall consistency of these measurements among different laboratories. The extensive use of this certified reference material (CRM) has been integrated in the French standard NF T90-471 (April 2010) and in the ISO Technical Specification 12 869 (Anon 2012 International Standardisation Organisation) for validating qPCR methods and ensuring the reliability of these methods. © 2013 The Society for Applied Microbiology.

  3. Standard reference materials (SRMs) for determination of organic contaminants in environmental samples.

    PubMed

    Wise, Stephen A; Poster, Dianne L; Kucklick, John R; Keller, Jennifer M; Vanderpol, Stacy S; Sander, Lane C; Schantz, Michele M

    2006-10-01

    For the past 25 years the National Institute of Standards and Technology (NIST) has developed certified reference materials (CRMs), known as standard reference materials (SRMs), for determination of organic contaminants in environmental matrices. Assignment of certified concentrations has usually been based on combining results from two or more independent analytical methods. The first-generation environmental-matrix SRMs were issued with certified concentrations for a limited number (5 to 10) of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Improvements in the analytical certification approach significantly expanded the number and classes of contaminants determined. Environmental-matrix SRMs currently available include air and diesel particulate matter, coal tar, marine and river sediment, mussel tissue, fish oil and tissue, and human serum, with concentrations typically assigned for 50 to 90 organic contaminants, for example PAHs, nitro-substituted PAHs, PCBs, chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs).

  4. Characterization of Three Berry Standard Reference Materials for Nutrients

    PubMed Central

    Wood, Laura J.; Sharpless, Katherine E.; Pichon, Monique; Porter, Barbara J.; Yen, James H.; Ehling, Stefan

    2011-01-01

    The National Institute of Standards and Technology (NIST) has been working with the National Institutes of Health Office of Dietary Supplements to produce Standard Reference Materials (SRMs) of interest to analysts of dietary supplements. Some of these SRMs are traditional foods including SRM 3281 Cranberry (Fruit), SRM 3282 Low-Calorie Cranberry Juice Cocktail, and SRM 3287 Blueberry (Fruit), which have been characterized for nine nutritional elements and sugars. The blueberries have also been characterized for proximates, two water-soluble vitamins, and amino acids. These new materials are intended for use in method development and validation as well as for quality assurance and traceability when assigning values to in-house control materials. Foods can be difficult to analyze because of matrix effects. With the addition of these three new SRMs, it is now possible to more closely match controls to matrices and analyte levels for fruit and vegetable test samples. Several nutritional elements in these three SRMs are present at lower levels than those in other food-matrix SRMs. PMID:21688777

  5. Junior High Basals: Effective Hi/Lo Materials for Remedial High School Readers.

    ERIC Educational Resources Information Center

    Alvermann, Donna E.

    1981-01-01

    Discusses the results of an analysis of the appropriateness of eighth-grade basal reading materials for remedial instruction of ninth- and tenth-grade students who read two to three years below grade level. Readability, interest appeal, and representation of content areas are considered. Three data tables and a 14-item reference list are included.…

  6. 26 CFR 1.6038A-0 - Table of contents.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Material profit and loss statements. (4) Existing records test. (5) Significant industry segment test. (i... 26 Internal Revenue 13 2014-04-01 2014-04-01 false Table of contents. 1.6038A-0 Section 1.6038A-0...) INCOME TAXES (CONTINUED) Information Returns § 1.6038A-0 Table of contents. This section lists the...

  7. 26 CFR 1.6038A-0 - Table of contents.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Material profit and loss statements. (4) Existing records test. (5) Significant industry segment test. (i... 26 Internal Revenue 13 2013-04-01 2013-04-01 false Table of contents. 1.6038A-0 Section 1.6038A-0...) INCOME TAXES (CONTINUED) Information Returns § 1.6038A-0 Table of contents. This section lists the...

  8. 26 CFR 1.6038A-0 - Table of contents.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Material profit and loss statements. (4) Existing records test. (5) Significant industry segment test. (i... 26 Internal Revenue 13 2011-04-01 2011-04-01 false Table of contents. 1.6038A-0 Section 1.6038A-0...) INCOME TAXES (CONTINUED) Information Returns § 1.6038A-0 Table of contents. This section lists the...

  9. 26 CFR 1.6038A-0 - Table of contents.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Material profit and loss statements. (4) Existing records test. (5) Significant industry segment test. (i... 26 Internal Revenue 13 2012-04-01 2012-04-01 false Table of contents. 1.6038A-0 Section 1.6038A-0...) INCOME TAXES (CONTINUED) Information Returns § 1.6038A-0 Table of contents. This section lists the...

  10. NBS/EPA (NATIONAL BUREAU OF STANDARDS/ENVIRONMENTAL PROTECTION AGENCY) CERTIFIED REFERENCE MATERIAL PERFORMANCE AUDIT PROGRAM: STATUS REPORT 1

    EPA Science Inventory

    A traceability procedure has been established which allows specialty gas producers to prepare gaseous pollutant Certified Reference Materials (CRMs). The accuracy, stability and homogeneity of the CRMs approach those of NBS Standard Reference Materials (SRMs). Part of this proced...

  11. NBS/EPA (NATIONAL BUREAU OF STANDARDS/ENVIRONMENTAL PROTECTION AGENCY) CERTIFIED REFERENCE MATERIAL PERFORMANCE AUDIT PROGRAM: STATUS REPORT 2

    EPA Science Inventory

    A traceability procedure has been established which allows specialty gas producers to prepare gaseous pollutant Certified Reference Materials (CRM's). The accuracy, stability and homogeneity of the CRM's approach those of NBS Standard Reference Materials (SRM's). As of October 19...

  12. Development of an extended straightness measurement reference

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schenz, R.F.; Griffith, L.V.; Sommargren, G.E.

    1988-09-06

    The most accurate diamond turning machines have used physical straightness references. These references commonly are made of optical materials, such as Zerodur, and are flat enough to permit straightness measurements with an accuracy of 100--150 nm (4--6 microinches) p-v. In most cases, the flatness error is stable and can be accommodated by using a calibration table. The straightedges for the Large Optics Diamond Turning Machine (LODTM) at Lawrence Livermore National Laboratory (LLNL) are 1.1 meters in length and allow a straightness reference accuracy of 25--50 nm (1--2 microinches) p-v after calibration. Fabrication problems become insurmountable when a straightness reference formore » a length of up to 4 meters is desired. Moreover, the method of calibration by straightedge reversal does not account for gravitational sag when the sensing direction is vertical. Vertical sensing would be required in a four meter system and sag would become unacceptably large. Recent developments published in the literature suggest that the use of a laser beam for a reference may be feasible. Workers at Osaka University have reported a laser beam straightness reference that has a resolution of 3.5 nm, although tests were done only over a 200 mm length. LLNL has begun an investigation on the use of a directionally stabilized laser beam as a straightness measurement reference. The goal of the investigation is to provide a reference that is accurate to 25 nm (1 microinch) over a four meter distance. 3 refs., 2 figs.« less

  13. 40 CFR Table 1 of Subpart Ppp of... - Applicability of General Provisions to Subpart PPP Affected Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Subpart PPP Affected Sources 1 Table 1 of Subpart PPP of Part 63 Protection of Environment ENVIRONMENTAL... Emissions for Polyether Polyols Production Pt. 63, Subpt. PPP, Table 1 Table 1 of Subpart PPP of Part 63—Applicability of General Provisions to Subpart PPP Affected Sources Reference Applies tosubpart PPP Explanation...

  14. 40 CFR Table 1 of Subpart Ppp of... - Applicability of General Provisions to Subpart PPP Affected Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Subpart PPP Affected Sources 1 Table 1 of Subpart PPP of Part 63 Protection of Environment ENVIRONMENTAL... Emissions for Polyether Polyols Production Pt. 63, Subpt. PPP, Table 1 Table 1 of Subpart PPP of Part 63—Applicability of General Provisions to Subpart PPP Affected Sources Reference Applies tosubpart PPP Explanation...

  15. 40 CFR Table 2 of Subpart Ppp of... - Applicability of General Provisions to Subpart PPP Affected Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart PPP Affected Sources 2 Table 2 of Subpart PPP of Part 63 Protection of Environment ENVIRONMENTAL... Polyether Polyols Production Pt. 63, Subpt. PPP, Table 2 Table 2 of Subpart PPP of Part 63—Applicability of General Provisions to Subpart PPP Affected Sources Reference Applies to subpart PPP Explanation Applicable...

  16. 40 CFR Table 2 of Subpart Ppp of... - Applicability of General Provisions to Subpart PPP Affected Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Subpart PPP Affected Sources 2 Table 2 of Subpart PPP of Part 63 Protection of Environment ENVIRONMENTAL... Polyether Polyols Production Pt. 63, Subpt. PPP, Table 2 Table 2 of Subpart PPP of Part 63—Applicability of General Provisions to Subpart PPP Affected Sources Reference Applies to subpart PPP Explanation Applicable...

  17. 40 CFR Table 2 of Subpart Ppp of... - Applicability of General Provisions to Subpart PPP Affected Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Subpart PPP Affected Sources 2 Table 2 of Subpart PPP of Part 63 Protection of Environment ENVIRONMENTAL... Polyether Polyols Production Pt. 63, Subpt. PPP, Table 2 Table 2 of Subpart PPP of Part 63—Applicability of General Provisions to Subpart PPP Affected Sources Reference Applies to subpart PPP Explanation Applicable...

  18. 10 CFR 32.24 - Same: Table of organ doses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... blood-forming organs; gonads: or lens of eye 0.001 0.01 0.5 15 Hands and forearms; feet and ankles... 10 Energy 1 2010-01-01 2010-01-01 false Same: Table of organ doses. 32.24 Section 32.24 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.24 Same: Table of organ doses. Part of...

  19. 10 CFR 32.28 - Same: Table of organ doses.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... organs; gonads; or lens of eye 0.005 0.5 15 Hands and forearms; feet and ankles; localized areas of skin... 10 Energy 1 2014-01-01 2014-01-01 false Same: Table of organ doses. 32.28 Section 32.28 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.28 Same: Table of organ doses. Part of...

  20. 10 CFR 32.24 - Same: Table of organ doses.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... blood-forming organs; gonads: or lens of eye 0.001 0.01 0.5 15 Hands and forearms; feet and ankles... 10 Energy 1 2014-01-01 2014-01-01 false Same: Table of organ doses. 32.24 Section 32.24 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.24 Same: Table of organ doses. Part of...

  1. 10 CFR 32.28 - Same: Table of organ doses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... organs; gonads; or lens of eye 0.005 0.5 15 Hands and forearms; feet and ankles; localized areas of skin... 10 Energy 1 2011-01-01 2011-01-01 false Same: Table of organ doses. 32.28 Section 32.28 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.28 Same: Table of organ doses. Part of...

  2. 10 CFR 32.28 - Same: Table of organ doses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... organs; gonads; or lens of eye 0.005 0.5 15 Hands and forearms; feet and ankles; localized areas of skin... 10 Energy 1 2012-01-01 2012-01-01 false Same: Table of organ doses. 32.28 Section 32.28 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.28 Same: Table of organ doses. Part of...

  3. 10 CFR 32.28 - Same: Table of organ doses.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... organs; gonads; or lens of eye 0.005 0.5 15 Hands and forearms; feet and ankles; localized areas of skin... 10 Energy 1 2013-01-01 2013-01-01 false Same: Table of organ doses. 32.28 Section 32.28 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.28 Same: Table of organ doses. Part of...

  4. 10 CFR 32.24 - Same: Table of organ doses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... blood-forming organs; gonads: or lens of eye 0.001 0.01 0.5 15 Hands and forearms; feet and ankles... 10 Energy 1 2011-01-01 2011-01-01 false Same: Table of organ doses. 32.24 Section 32.24 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.24 Same: Table of organ doses. Part of...

  5. 10 CFR 32.28 - Same: Table of organ doses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... organs; gonads; or lens of eye 0.005 0.5 15 Hands and forearms; feet and ankles; localized areas of skin... 10 Energy 1 2010-01-01 2010-01-01 false Same: Table of organ doses. 32.28 Section 32.28 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.28 Same: Table of organ doses. Part of...

  6. 10 CFR 32.24 - Same: Table of organ doses.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... blood-forming organs; gonads: or lens of eye 0.001 0.01 0.5 15 Hands and forearms; feet and ankles... 10 Energy 1 2013-01-01 2013-01-01 false Same: Table of organ doses. 32.24 Section 32.24 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.24 Same: Table of organ doses. Part of...

  7. 10 CFR 32.24 - Same: Table of organ doses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... blood-forming organs; gonads: or lens of eye 0.001 0.01 0.5 15 Hands and forearms; feet and ankles... 10 Energy 1 2012-01-01 2012-01-01 false Same: Table of organ doses. 32.24 Section 32.24 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.24 Same: Table of organ doses. Part of...

  8. 26 CFR 1.6038A-0 - Table of contents.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Material profit and loss statements. (4) Existing records test. (5) Significant industry segment test. (i... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Table of contents. 1.6038A-0 Section 1.6038A-0...) INCOME TAXES Information Returns § 1.6038A-0 Table of contents. This section lists the captions that...

  9. Establishing the traceability of a uranyl nitrate solution to a standard reference material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, C.H.; Clark, J.P.

    1978-01-01

    A uranyl nitrate solution for use as a Working Calibration and Test Material (WCTM) was characterized, using a statistically designed procedure to document traceability to National Bureau of Standards Reference Material (SPM-960). A Reference Calibration and Test Material (PCTM) was prepared from SRM-960 uranium metal to approximate the acid and uranium concentration of the WCTM. This solution was used in the characterization procedure. Details of preparing, handling, and packaging these solutions are covered. Two outside laboratories, each having measurement expertise using a different analytical method, were selected to measure both solutions according to the procedure for characterizing the WCTM. Twomore » different methods were also used for the in-house characterization work. All analytical results were tested for statistical agreement before the WCTM concentration and limit of error values were calculated. A concentration value was determined with a relative limit of error (RLE) of approximately 0.03% which was better than the target RLE of 0.08%. The use of this working material eliminates the expense of using SRMs to fulfill traceability requirements for uranium measurements on this type material. Several years' supply of uranyl nitrate solution with NBS traceability was produced. The cost of this material was less than 10% of an equal quantity of SRM-960 uranium metal.« less

  10. Extensive sequencing of seven human genomes to characterize benchmark reference materials

    PubMed Central

    Zook, Justin M.; Catoe, David; McDaniel, Jennifer; Vang, Lindsay; Spies, Noah; Sidow, Arend; Weng, Ziming; Liu, Yuling; Mason, Christopher E.; Alexander, Noah; Henaff, Elizabeth; McIntyre, Alexa B.R.; Chandramohan, Dhruva; Chen, Feng; Jaeger, Erich; Moshrefi, Ali; Pham, Khoa; Stedman, William; Liang, Tiffany; Saghbini, Michael; Dzakula, Zeljko; Hastie, Alex; Cao, Han; Deikus, Gintaras; Schadt, Eric; Sebra, Robert; Bashir, Ali; Truty, Rebecca M.; Chang, Christopher C.; Gulbahce, Natali; Zhao, Keyan; Ghosh, Srinka; Hyland, Fiona; Fu, Yutao; Chaisson, Mark; Xiao, Chunlin; Trow, Jonathan; Sherry, Stephen T.; Zaranek, Alexander W.; Ball, Madeleine; Bobe, Jason; Estep, Preston; Church, George M.; Marks, Patrick; Kyriazopoulou-Panagiotopoulou, Sofia; Zheng, Grace X.Y.; Schnall-Levin, Michael; Ordonez, Heather S.; Mudivarti, Patrice A.; Giorda, Kristina; Sheng, Ying; Rypdal, Karoline Bjarnesdatter; Salit, Marc

    2016-01-01

    The Genome in a Bottle Consortium, hosted by the National Institute of Standards and Technology (NIST) is creating reference materials and data for human genome sequencing, as well as methods for genome comparison and benchmarking. Here, we describe a large, diverse set of sequencing data for seven human genomes; five are current or candidate NIST Reference Materials. The pilot genome, NA12878, has been released as NIST RM 8398. We also describe data from two Personal Genome Project trios, one of Ashkenazim Jewish ancestry and one of Chinese ancestry. The data come from 12 technologies: BioNano Genomics, Complete Genomics paired-end and LFR, Ion Proton exome, Oxford Nanopore, Pacific Biosciences, SOLiD, 10X Genomics GemCode WGS, and Illumina exome and WGS paired-end, mate-pair, and synthetic long reads. Cell lines, DNA, and data from these individuals are publicly available. Therefore, we expect these data to be useful for revealing novel information about the human genome and improving sequencing technologies, SNP, indel, and structural variant calling, and de novo assembly. PMID:27271295

  11. Development of a reference material of a single DNA molecule for the quality control of PCR testing.

    PubMed

    Mano, Junichi; Hatano, Shuko; Futo, Satoshi; Yoshii, Junji; Nakae, Hiroki; Naito, Shigehiro; Takabatake, Reona; Kitta, Kazumi

    2014-09-02

    We developed a reference material of a single DNA molecule with a specific nucleotide sequence. The double-strand linear DNA which has PCR target sequences at the both ends was prepared as a reference DNA molecule, and we named the PCR targets on each side as confirmation sequence and standard sequence. The highly diluted solution of the reference molecule was dispensed into 96 wells of a plastic PCR plate to make the average number of molecules in a well below one. Subsequently, the presence or absence of the reference molecule in each well was checked by real-time PCR targeting for the confirmation sequence. After an enzymatic treatment of the reaction mixture in the positive wells for the digestion of PCR products, the resultant solution was used as the reference material of a single DNA molecule with the standard sequence. PCR analyses revealed that the prepared samples included only one reference molecule with high probability. The single-molecule reference material developed in this study will be useful for the absolute evaluation of a detection limit of PCR-based testing methods, the quality control of PCR analyses, performance evaluations of PCR reagents and instruments, and the preparation of an accurate calibration curve for real-time PCR quantitation.

  12. 40 CFR Table 1 of Subpart Ppp of... - Applicability of General Provisions to Subpart PPP Affected Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Subpart PPP Affected Sources 1 Table 1 of Subpart PPP of Part 63 Protection of Environment ENVIRONMENTAL... Polyether Polyols Production Pt. 63, Subpt. PPP, Table 1 Table 1 of Subpart PPP of Part 63—Applicability of General Provisions to Subpart PPP Affected Sources Reference Applies tosubpart PPP Explanation 63.1(a)(1...

  13. 40 CFR Table 1 of Subpart Ppp of... - Applicability of General Provisions to Subpart PPP Affected Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart PPP Affected Sources 1 Table 1 of Subpart PPP of Part 63 Protection of Environment ENVIRONMENTAL... Polyether Polyols Production Pt. 63, Subpt. PPP, Table 1 Table 1 of Subpart PPP of Part 63—Applicability of General Provisions to Subpart PPP Affected Sources Reference Applies tosubpart PPP Explanation 63.1(a)(1...

  14. 40 CFR Table 2 of Subpart Ppp of... - Applicability of General Provisions to Subpart PPP Affected Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Subpart PPP Affected Sources 2 Table 2 of Subpart PPP of Part 63 Protection of Environment ENVIRONMENTAL... Emissions for Polyether Polyols Production Pt. 63, Subpt. PPP, Table 2 Table 2 of Subpart PPP of Part 63—Applicability of General Provisions to Subpart PPP Affected Sources Reference Applies to subpart PPP Explanation...

  15. 40 CFR Table 2 of Subpart Ppp of... - Applicability of HON Provisions to Subpart PPP Affected Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Subpart PPP Affected Sources 2 Table 2 of Subpart PPP of Part 63 Protection of Environment ENVIRONMENTAL... Emissions for Polyether Polyols Production Pt. 63, Subpt. PPP, Table 2 Table 2 of Subpart PPP of Part 63—Applicability of HON Provisions to Subpart PPP Affected Sources Reference Applies to subpart PPP Explanation...

  16. 40 CFR Table 1 of Subpart Ppp of... - Applicability of General Provisions to Subpart PPP Affected Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Subpart PPP Affected Sources 1 Table 1 of Subpart PPP of Part 63 Protection of Environment ENVIRONMENTAL... Polyether Polyols Production Pt. 63, Subpt. PPP, Table 1 Table 1 of Subpart PPP of Part 63—Applicability of General Provisions to Subpart PPP Affected Sources Reference Applies tosubpart PPP Explanation 63.1(a)(1...

  17. Analysis of polycyclic aromatic hydrocarbons in sediment reference materials by microwave-assisted extraction.

    PubMed

    Shu, Y Y; Lao, R C; Chiu, C H; Turle, R

    2000-12-01

    The microwave-assisted extraction (MAE) of polycyclic aromatic hydrocarbons (PAHs) from harbor sediment reference material EC-1, marine sediment reference material HS-2 and PAH-spiked river bed soil was conducted. The extraction conditions for EC-1 were carried out at 70 degrees C and 100 degrees C under pressure in closed vessels with cyclohexane acetone (1:1), cyclohexane-water (3:1), hexane acetone (1:1), and hexane-water (3:1) for 10 min. A comparison between MAE and a 16-h Soxhlet extraction (SX) method showed that both techniques gave comparable results with certified values. MAE has advantages over the currently used Soxhlet technique due to a faster extraction time and lower quantity of solvent used. The consumption of organic solvent of the microwave method was less than one-tenth compared to Soxhlet.

  18. HOW OLD IS IT? - 241PU/241AM NUCLEAR FORENSIC CHRONOLOGY REFERENCE MATERIALS

    PubMed Central

    Fitzgerald, Ryan; Inn, Kenneth G.W.; Horgan, Christopher

    2018-01-01

    One material attribute for nuclear forensics is material age. 241Pu is almost always present in uranium- and plutonium-based nuclear weapons, which pose the greatest threat to our security. The in-growth of 241Am due to the decay of 241Pu provides an excellent chronometer of the material. A well-characterized 241Pu/241Am standard is needed to validate measurement capability, as a basis for between-laboratory comparability, and as material for verifying laboratory performance. This effort verifies the certification of a 38 year old 241Pu Standard Reference Material (SRM4340) through alpha-gamma anticoincidence counting, and also establishes the separation date to two weeks of the documented date. PMID:29720779

  19. A feasibility study for producing an egg matrix candidate reference material for the polyether ionophore salinomycin.

    PubMed

    Ferreira, Rosana Gomes; Monteiro, Mychelle Alves; Pereira, Mararlene Ulberg; da Costa, Rafaela Pinto; Spisso, Bernardete Ferraz; Calado, Veronica

    2016-08-01

    The aim of this work was to study the feasibility of producing an egg matrix candidate reference material for salinomycin. Preservation techniques investigated were freeze-drying and spray drying dehydration. Homogeneity and stability studies of the produced batches were conducted according to ISO Guides 34 and 35. The results showed that all produced batches were homogeneous and both freeze-drying and spray drying techniques were suitable for matrix dehydrating, ensuring the material stability. In order to preserve the material integrity, it must be transported within the temperature range of -20 up to 25°C. The results constitute an important step towards the development of an egg matrix reference material for salinomycin is possible. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Mesa = Table

    NASA Technical Reports Server (NTRS)

    2006-01-01

    10 August 2006 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows two mesas on the northern plains of Mars. 'Mesa' is the Spanish word for 'table,' and that is a very good description of the two elliptical features captured in this MOC image. In both cases, the mesa tops and the material beneath them, down to the level of the surrounding, rugged plain, are remnants of a once more extensive layer (or layers) of material that has been largely eroded away. The circular feature near the center of the larger mesa is the site of a filled and buried impact crater.

    Location near: 53.5oN, 153.5oW Image width: 3 km (1.9 mi) Illumination from: lower left Season: Northern Spring

  1. Development of saw palmetto (Serenoa repens) fruit and extract standard reference materials.

    PubMed

    Schantz, Michele M; Bedner, Mary; Long, Stephen E; Molloy, John L; Murphy, Karen E; Porter, Barbara J; Putzbach, Karsten; Rimmer, Catherine A; Sander, Lane C; Sharpless, Katherine E; Thomas, Jeanice B; Wise, Stephen A; Wood, Laura J; Yen, James H; Yarita, Takashi; NguyenPho, Agnes; Sorenson, Wendy R; Betz, Joseph M

    2008-10-01

    As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.

  2. A Table! (At the Table).

    ERIC Educational Resources Information Center

    Terry, Robert M.

    A review of French dining habits and table manners outlines: elements of the place setting, courtesies used at the table, serving conventions, restaurant tipping, the size and content of the different meals of the day, subtle differences in common foods, restaurant types, menu types, general wine and cheese choices, waiter-client communication,…

  3. New Wavenumber Calibration Tables From Heterodyne Frequency Measurements

    PubMed Central

    Maki, Arthur G.; Wells, Joseph S.

    1992-01-01

    This new calibration atlas is based on frequency rather than wavelength calibration techniques for absolute references. Since a limited number of absolute frequency measurements is possible, additional data from alternate methodology are used for difference frequency measurements within each band investigated by the frequency measurements techniques. Data from these complementary techniques include the best Fourier transform measurements available. Included in the text relating to the atlas are a description of the heterodyne frequency measurement techniques and details of the analysis, including the Hamiltonians and least-squares-fitting and calculation. Also included are other relevant considerations such as intensities and lincshape parameters. A 390-entry bibliography which contains all data sources used and a subsequent section on errors conclude the text portion. The primary calibration molecules are the linear triatomics, carbonyl sulfide and nitrous oxide, which cover portions of the infrared spectrum ranging from 488 to 3120 cm−1. Some gaps in the coverage afforded by OCS and N2O are partially covered by NO, CO, and CS2. An additional region from 4000 to 4400 cm−1 is also included. The tabular portion of the atlas is too lengthy to include in an archival journal. Furthermore, different users have different requirements for such an atlas. In an effort to satisfy most users, we have made two different options available. The first is NIST Special Publication 821, which has a spectral map/facing table format. The spectral maps (as well as the facing tables) are calculated from molecular constants derived for the work. A complete list of all of the molecular transitions that went into making the maps is too long (perhaps by a factor of 4 or 5) to include in the facing tables. The second option for those not interested in maps (or perhaps to supplement Special Publication 821) is the complete list (tables-only) which is available in computerized format as

  4. Apollo by the Numbers: A Statistical Reference

    NASA Technical Reports Server (NTRS)

    Orloff, Richard; Garber, Stephen (Technical Monitor)

    2000-01-01

    The purpose of this work is to provide researchers, students, and space enthusiasts with a comprehensive reference for facts about Project Apollo, America's effort to put humans in the Moon. Research for this work started in 1988, when the author discovered that, despite the number of excellent books that focused on the drama of events that highlighted Apollo, there were none that focused on the drama of the numbers. This book is separated into two parts. The first part contains narratives for the Apollo 1 fire and the 11 flown Apollo missions. Included after each narrative is a series of data tables, followed by a comprehensive timeline of events from just before liftoff to just after crew and spacecraft recovery. The second part contains more than 50 tables. These tables organize much of the data from the narratives in one place so they can be compared among all missions. The tables offer additional data as well. The reader can select a specific mission narrative or specific data table by consulting the Table of Contents.

  5. Certified reference materials for testing of the presence/absence of Staphylococcus aureus enterotoxin A (SEA) in cheese.

    PubMed

    Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric

    2016-08-01

    Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.

  6. Validation of reference materials for uranium radiochronometry in the frame of nuclear forensic investigations

    DOE PAGES

    Varga, Z.; Mayer, K.; Bonamici, C. E.; ...

    2015-05-11

    The results of a joint effort by expert nuclear forensic laboratories in the area of age dating of uranium, i.e. the elapsed time since the last chemical purification of the material are presented and discussed. Completely separated uranium materials of known production date were distributed among the laboratories, and the samples were dated according to routine laboratory procedures by the measurement of the ²²⁰Th/²³⁴U ratio. The measurement results were in good agreement with the known production date showing that the concept for preparing uranium age dating reference material based on complete separation is valid. Detailed knowledge of the laboratory proceduresmore » used for uranium age dating allows the identification of possible improvements in the current protocols and the development of improved practice in the future. The availability of age dating reference materials as well as the evolvement of the age dating best-practice protocol will increase the relevance and applicability of age dating as part of the tool-kit available for nuclear forensic investigations.« less

  7. Validation of reference materials for uranium radiochronometry in the frame of nuclear forensic investigations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varga, Z.; Mayer, K.; Bonamici, C. E.

    The results of a joint effort by expert nuclear forensic laboratories in the area of age dating of uranium, i.e. the elapsed time since the last chemical purification of the material are presented and discussed. Completely separated uranium materials of known production date were distributed among the laboratories, and the samples were dated according to routine laboratory procedures by the measurement of the ²²⁰Th/²³⁴U ratio. The measurement results were in good agreement with the known production date showing that the concept for preparing uranium age dating reference material based on complete separation is valid. Detailed knowledge of the laboratory proceduresmore » used for uranium age dating allows the identification of possible improvements in the current protocols and the development of improved practice in the future. The availability of age dating reference materials as well as the evolvement of the age dating best-practice protocol will increase the relevance and applicability of age dating as part of the tool-kit available for nuclear forensic investigations.« less

  8. Selected Bibliography on Culture and Cultural Materials, Preliminary Edition. Series A: Reference Materials, Human Relations in Cultural Context.

    ERIC Educational Resources Information Center

    Condon, E. C.; And Others

    Included in this bibliography are references to resources and materials available to the teacher and educator on human relations and cultural education. The bibliography is divided into three sections on culture, specific culture, and adult bilingual-bicultural education. The section on culture presents background information on the relation of…

  9. Quantification of the predominant monomeric catechins in baking chocolate standard reference material by LC/APCI-MS.

    PubMed

    Nelson, Bryant C; Sharpless, Katherine E

    2003-01-29

    Catechins are polyphenolic plant compounds (flavonoids) that may offer significant health benefits to humans. These benefits stem largely from their anticarcinogenic, antioxidant, and antimutagenic properties. Recent epidemiological studies suggest that the consumption of flavonoid-containing foods is associated with reduced risk of cardiovascular disease. Chocolate is a natural cocoa bean-based product that reportedly contains high levels of monomeric, oligomeric, and polymeric catechins. We have applied solid-liquid extraction and liquid chromatography coupled with atmospheric pressure chemical ionization-mass spectrometry to the identification and determination of the predominant monomeric catechins, (+)-catechin and (-)-epicatechin, in a baking chocolate Standard Reference Material (NIST Standard Reference Material 2384). (+)-Catechin and (-)-epicatechin are detected and quantified in chocolate extracts on the basis of selected-ion monitoring of their protonated [M + H](+) molecular ions. Tryptophan methyl ester is used as an internal standard. The developed method has the capacity to accurately quantify as little as 0.1 microg/mL (0.01 mg of catechin/g of chocolate) of either catechin in chocolate extracts, and the method has additionally been used to certify (+)-catechin and (-)-epicatechin levels in the baking chocolate Standard Reference Material. This is the first reported use of liquid chromatography/mass spectrometry for the quantitative determination of monomeric catechins in chocolate and the only report certifying monomeric catechin levels in a food-based Standard Reference Material.

  10. Bute's "Botanical tables": dictated by nature.

    PubMed

    Lazarus, Maureen H; Pardoe, Heather S

    2009-10-01

    In the final years of his life, after a long and turbulent political career, John Stuart, third Earl of Bute, was at last free to indulge in one of his passions: botany. The publication of Linnaeus's "Systema naturae" in 1735 threw the botanical world into disarray and academic argument raged throughout Europe. The production of the "Botanical tables" (1785) was an ambitious project to explain Bute's individual view of Linnaeus's system of taxonomy and was particularly composed for the "Fair Sex". Twelve volumes were published privately and presented to family, royalty and botanical colleagues across Europe. The "Botanical tables" were illustrated by the renowned botanical artist, John Miller. The illustrations are both aesthetically pleasing and scientifically correct. In this paper we consider the circumstances of the production of the "Botanical tables" and explore how the original sets of this publication and original material have been dispersed.

  11. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, R W; Gaffney, A M; Kristo, M J

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumptionmore » of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.« less

  12. On the status of IAEA delta-13C stable isotope reference materials.

    NASA Astrophysics Data System (ADS)

    Assonov, Sergey; Groening, Manfred; Fajgelj, Ales

    2016-04-01

    For practical reasons all isotope measurements are performed on relative scales realized through the use of international, scale-defining primary standards. In fact these standards were materials (artefacts, similar to prototypes of meter and kg) selected based on their properties. The VPDB delta-13C scale is realised via two highest-level reference materials NBS19 and LSVEC, the first defining the scale and the second aimed to normalise lab-to-lab calibrations. These two reference materials (RMs) have been maintained and distributed by IAEA and NIST. The priority task is to maintain these primary RMs at the required uncertainty level, thus ensuring the long-term scale consistency. The second task is to introduce replacements when needed (currently for exhausted NBS19, work in progress). The next is to produce a family of lower level RMs (secondary, tertiary) addressing needs of various applications (with different delta values, in different physical-chemical forms) and their needs for the uncertainty; these RMs should be traceable to the highest level RMs. Presently three is a need for a range of RMs addressing existing and newly emerging analytical techniques (e.g. optical isotopic analysers) in form of calibrated CO2 gases with different delta-13C values. All that implies creating a family of delta-13C stable isotope reference materials. Presently IAEA works on replacement for NBS19 and planning new RMs. Besides, we found that LSVEC (introduced as second anchor for the VPDB scale in 2006) demonstrate a considerable scatter of its delta-13C value which implies a potential bias of the property value and increased value uncertainty which may conflict with uncertainty requirements for atmospheric monitoring. That is not compatible with the status of LSVEC, and therefore it should be replaced as soon as possible. The presentation will give an overview of the current status, the strategic plan of developments and the near future steps.

  13. Data tables for the 1994 National Transit Database report year

    DOT National Transportation Integrated Search

    1995-12-01

    The Data Tables For the 1994 National Transit Database Report Year is one of three publications also referred to as the National Transit Databse Reporting System. The report provides detailed summaries of financial and operating data submitted to FTA...

  14. Software Management Environment (SME) release 9.4 user reference material

    NASA Technical Reports Server (NTRS)

    Hendrick, R.; Kistler, D.; Manter, K.

    1992-01-01

    This document contains user reference material for the Software Management Environment (SME) prototype, developed for the Systems Development Branch (Code 552) of the Flight Dynamics Division (FDD) of Goddard Space Flight Center (GSFC). The SME provides an integrated set of management tools that can be used by software development managers in their day-to-day management and planning activities. This document provides an overview of the SME, a description of all functions, and detailed instructions concerning the software's installation and use.

  15. A New Method for Generating Probability Tables in the Unresolved Resonance Region

    DOE PAGES

    Holcomb, Andrew M.; Leal, Luiz C.; Rahnema, Farzad; ...

    2017-04-18

    One new method for constructing probability tables in the unresolved resonance region (URR) has been developed. This new methodology is an extensive modification of the single-level Breit-Wigner (SLBW) pseudo-resonance pair sequence method commonly used to generate probability tables in the URR. The new method uses a Monte Carlo process to generate many pseudo-resonance sequences by first sampling the average resonance parameter data in the URR and then converting the sampled resonance parameters to the more robust R-matrix limited (RML) format. Furthermore, for each sampled set of pseudo-resonance sequences, the temperature-dependent cross sections are reconstructed on a small grid around themore » energy of reference using the Reich-Moore formalism and the Leal-Hwang Doppler broadening methodology. We then use the effective cross sections calculated at the energies of reference to construct probability tables in the URR. The RML cross-section reconstruction algorithm has been rigorously tested for a variety of isotopes, including 16O, 19F, 35Cl, 56Fe, 63Cu, and 65Cu. The new URR method also produced normalized cross-section factor probability tables for 238U that were found to be in agreement with current standards. The modified 238U probability tables were shown to produce results in excellent agreement with several standard benchmarks, including the IEU-MET-FAST-007 (BIG TEN), IEU-MET-FAST-003, and IEU-COMP-FAST-004 benchmarks.« less

  16. STILTS -- Starlink Tables Infrastructure Library Tool Set

    NASA Astrophysics Data System (ADS)

    Taylor, Mark

    STILTS is a set of command-line tools for processing tabular data. It has been designed for, but is not restricted to, use on astronomical data such as source catalogues. It contains both generic (format-independent) table processing tools and tools for processing VOTable documents. Facilities offered include crossmatching, format conversion, format validation, column calculation and rearrangement, row selection, sorting, plotting, statistical calculations and metadata display. Calculations on cell data can be performed using a powerful and extensible expression language. The package is written in pure Java and based on STIL, the Starlink Tables Infrastructure Library. This gives it high portability, support for many data formats (including FITS, VOTable, text-based formats and SQL databases), extensibility and scalability. Where possible the tools are written to accept streamed data so the size of tables which can be processed is not limited by available memory. As well as the tutorial and reference information in this document, detailed on-line help is available from the tools themselves. STILTS is available under the GNU General Public Licence.

  17. Preparation and characterization of a suite of ephedra-containing standard reference materials.

    PubMed

    Sharpless, Katherine E; Anderson, David L; Betz, Joseph M; Butler, Therese A; Capar, Stephen G; Cheng, John; Fraser, Catharine A; Gardner, Graeme; Gay, Martha L; Howell, Daniel W; Ihara, Toshihide; Khan, Mansoor A; Lam, Joseph W; Long, Stephen E; McCooeye, Margaret; Mackey, Elizabeth A; Mindak, William R; Mitvalsky, Staci; Murphy, Karen E; NguyenPho, Agnes; Phinney, Karen W; Porter, Barbara J; Roman, Mark; Sander, Lane C; Satterfield, Mary B; Scriver, Christine; Sturgeon, Ralph; Thomas, Jeanice Brown; Vocke, Robert D; Wise, Stephen A; Wood, Laura J; Yang, Lu; Yen, James H; Ziobro, George C

    2006-01-01

    The National Institute of Standards and Technology, the U.S. Food and Drug Administration, Center for Drug Evaluation and Research and Center for Food Safety and Applied Nutrition, and the National Institutes of Health, Office of Dietary Supplements, are collaborating to produce a series of Standard Reference Materials (SRMs) for dietary supplements. A suite of ephedra materials is the first in the series, and this paper describes the acquisition, preparation, and value assignment of these materials: SRMs 3240 Ephedra sinica Stapf Aerial Parts, 3241 E. sinica Stapf Native Extract, 3242 E. sinica Stapf Commercial Extract, 3243 Ephedra-Containing Solid Oral Dosage Form, and 3244 Ephedra-Containing Protein Powder. Values are assigned for ephedrine alkaloids and toxic elements in all 5 materials. Values are assigned for other analytes (e.g., caffeine, nutrient elements, proximates, etc.) in some of the materials, as appropriate. Materials in this suite of SRMs are intended for use as primary control materials when values are assigned to in-house (secondary) control materials and for validation of analytical methods for the measurement of alkaloids, toxic elements, and, in the case of SRM 3244, nutrients in similar materials.

  18. Life expectancy--a commentary on this life table variable.

    PubMed

    Singer, Richard B

    2005-01-01

    In 1992, I wrote an article on a method of modifying the Decennial US Life Table to accommodate any pattern of excess mortality expressed in terms of excess death rate (EDR), for the specific purpose of calculating the reduced life expectancy, e. I believe this was the first article published in the Journal of Insurance Medicine (JIM) that dealt specifically with life expectancy as an index of survival and risk appraisal, never used in the classification of extra mortality risk in applicants for life insurance. In this commentary, I discuss the 1989-91 US Decennial Life Table in detail. I link the subject matter of the 1992 article with several more recent articles that also focus on the utility of life expectancy in underwriting structured settlement annuities and preparing reports on life expectancy for an attorney in a tort case. A few references are given for further reading on life table methodology and its use in the most accurate estimate of life expectancy, given the inherent limitations of the life table and the limited duration of follow-up studies.

  19. Synthetic Reference Materials Based on Polymer Films for the Control of Welding Fumes Composition

    NASA Astrophysics Data System (ADS)

    Kuznetsova, O. V.; Kuznetsova, A. N.; Begunova, L. A.

    2017-04-01

    Analysis of the current hygienic situation in the welding production showed that the intensification of welding processes involves the deterioration of air quality, which negatively affects the welders health. Welders are exposed to a variety of metal fumes, including manganese that may elevate the risk for neurological diseases. The control of metals concentration in the air of the working area is difficult due to the lack of reference materials. The creation of reference materials of welding fumes composition is a challenge due to chemical characteristics of their physical properties. Synthetic samples in a form of the polymer film containing powder particles of welding fumes were create. Studies on the selection of the polymer were done. Experiments proved that the qualitative materials of synthetic welding fumes are obtained by using polyvinyl alcohol. The metals concentration in the samples was determined by X-ray fluorescence analysis. The obtained data demonstrates indirectly the uniform distribution of welding fumes powder particles on the polymer film.

  20. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. II. Selection of direct Kjeldahl analysis and its preliminary performance parameters.

    PubMed

    Vinklárková, Bára; Chromý, Vratislav; Šprongl, Luděk; Bittová, Miroslava; Rikanová, Milena; Ohnútková, Ivana; Žaludová, Lenka

    2015-01-01

    To select a Kjeldahl procedure suitable for the determination of total protein in reference materials used in laboratory medicine, we reviewed in our previous article Kjeldahl methods adopted by clinical chemistry and found an indirect two-step analysis by total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. In this article, we compare both procedures on various reference materials. An indirect Kjeldahl method gave falsely lower results than a direct analysis. Preliminary performance parameters qualify the direct Kjeldahl analysis as a suitable primary reference procedure for the certification of total protein in reference laboratories.

  1. Mortality table construction

    NASA Astrophysics Data System (ADS)

    Sutawanir

    2015-12-01

    Mortality tables play important role in actuarial studies such as life annuities, premium determination, premium reserve, valuation pension plan, pension funding. Some known mortality tables are CSO mortality table, Indonesian Mortality Table, Bowers mortality table, Japan Mortality table. For actuary applications some tables are constructed with different environment such as single decrement, double decrement, and multiple decrement. There exist two approaches in mortality table construction : mathematics approach and statistical approach. Distribution model and estimation theory are the statistical concepts that are used in mortality table construction. This article aims to discuss the statistical approach in mortality table construction. The distributional assumptions are uniform death distribution (UDD) and constant force (exponential). Moment estimation and maximum likelihood are used to estimate the mortality parameter. Moment estimation methods are easier to manipulate compared to maximum likelihood estimation (mle). However, the complete mortality data are not used in moment estimation method. Maximum likelihood exploited all available information in mortality estimation. Some mle equations are complicated and solved using numerical methods. The article focus on single decrement estimation using moment and maximum likelihood estimation. Some extension to double decrement will introduced. Simple dataset will be used to illustrated the mortality estimation, and mortality table.

  2. Spectral Retrieval of Latent Heating Profiles from TRMM PR Data: Comparison of Look-Up Tables

    NASA Technical Reports Server (NTRS)

    Shige, Shoichi; Takayabu, Yukari N.; Tao, Wei-Kuo; Johnson, Daniel E.; Shie, Chung-Lin

    2003-01-01

    The primary goal of the Tropical Rainfall Measuring Mission (TRMM) is to use the information about distributions of precipitation to determine the four dimensional (i.e., temporal and spatial) patterns of latent heating over the whole tropical region. The Spectral Latent Heating (SLH) algorithm has been developed to estimate latent heating profiles for the TRMM Precipitation Radar (PR) with a cloud- resolving model (CRM). The method uses CRM- generated heating profile look-up tables for the three rain types; convective, shallow stratiform, and anvil rain (deep stratiform with a melting level). For convective and shallow stratiform regions, the look-up table refers to the precipitation top height (PTH). For anvil region, on the other hand, the look- up table refers to the precipitation rate at the melting level instead of PTH. For global applications, it is necessary to examine the universality of the look-up table. In this paper, we compare the look-up tables produced from the numerical simulations of cloud ensembles forced with the Tropical Ocean Global Atmosphere (TOGA) Coupled Atmosphere-Ocean Response Experiment (COARE) data and the GARP Atlantic Tropical Experiment (GATE) data. There are some notable differences between the TOGA-COARE table and the GATE table, especially for the convective heating. First, there is larger number of deepest convective profiles in the TOGA-COARE table than in the GATE table, mainly due to the differences in SST. Second, shallow convective heating is stronger in the TOGA COARE table than in the GATE table. This might be attributable to the difference in the strength of the low-level inversions. Third, altitudes of convective heating maxima are larger in the TOGA COARE table than in the GATE table. Levels of convective heating maxima are located just below the melting level, because warm-rain processes are prevalent in tropical oceanic convective systems. Differences in levels of convective heating maxima probably reflect

  3. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specification

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Measurements Required, and Maximum Discrepancy Specification C Table C-1 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges..., June 22, 2010, table C-1 to subpart C was revised, effective Aug. 23, 2010. For the convenience of the...

  4. The determination of water in crude oil and transformer oil reference materials.

    PubMed

    Margolis, Sam A; Hagwood, Charles

    2003-05-01

    The measurement of the amount of water in oils is of significant economic importance to the industrial community, particularly to the electric power and crude oil industries. The amount of water in transformer oils is critical to their normal function and the amount of water in crude oils affects the cost of the crude oil at the well head, the pipeline, and the refinery. Water in oil Certified Reference Materials (CRM) are essential for the accurate calibration of instruments that are used by these industries. Three NIST Standard Reference Materials (SRMs) have been prepared for this purpose. The water in these oils has been measured by both coulometric and volumetric Karl Fischer methods. The compounds (such as sulfur compounds) that interfere with the Karl Fischer reaction (interfering substances) and inflate the values for water by also reacting with iodine have been measured coulometrically. The measured water content of Reference Material (RM) 8506a Transformer Oil is 12.1+/-1.9 mg kg(-1) (plus an additional 6.2+/-0.9 mg kg(-1) of interfering substances). The measured water content of SRM 2722 Sweet Crude Oil, is 99+/-6 mg kg(-1) (plus an additional 5+/-2 mg kg(-1) of interfering substances). The measured water content of SRM 2721 Sour Crude Oil, is 134+/-18 mg kg(-1) plus an additional 807+/-43 mg kg(-1) of interfering substances. Interlaboratory studies conducted with these oil samples (using SRM 2890, water saturated 1-octanol, as a calibrant) are reported. Some of the possible sources of bias in these measurements were identified, These include: improperly calibrated instruments, inability to measure the calibrant accurately, Karl Fischer reagent selection, and volatilization of the interfering substances in SRM 2721.

  5. Metrological approaches to organic chemical purity: primary reference materials for vitamin D metabolites.

    PubMed

    Nelson, Michael A; Bedner, Mary; Lang, Brian E; Toman, Blaza; Lippa, Katrice A

    2015-11-01

    Given the critical role of pure, organic compound primary reference standards used to characterize and certify chemical Certified Reference Materials (CRMs), it is essential that associated mass purity assessments be fit-for-purpose, represented by an appropriate uncertainty interval, and metrologically sound. The mass fraction purities (% g/g) of 25-hydroxyvitamin D (25(OH)D) reference standards used to produce and certify values for clinical vitamin D metabolite CRMs were investigated by multiple orthogonal quantitative measurement techniques. Quantitative (1)H-nuclear magnetic resonance spectroscopy (qNMR) was performed to establish traceability of these materials to the International System of Units (SI) and to directly assess the principal analyte species. The 25(OH)D standards contained volatile and water impurities, as well as structurally-related impurities that are difficult to observe by chromatographic methods or to distinguish from the principal 25(OH)D species by one-dimensional NMR. These impurities have the potential to introduce significant biases to purity investigations in which a limited number of measurands are quantified. Combining complementary information from multiple analytical methods, using both direct and indirect measurement techniques, enabled mitigation of these biases. Purities of 25(OH)D reference standards and associated uncertainties were determined using frequentist and Bayesian statistical models to combine data acquired via qNMR, liquid chromatography with UV absorbance and atmospheric pressure-chemical ionization mass spectrometric detection (LC-UV, LC-ACPI-MS), thermogravimetric analysis (TGA), and Karl Fischer (KF) titration.

  6. Development of a mushroom powder Certified Reference Material for calcium, arsenic, cadmium and lead measurements.

    PubMed

    Chew, Gina; Sim, Lay Peng; Ng, Sin Yee; Ding, Yi; Shin, Richard Y C; Lee, Tong Kooi

    2016-01-01

    Isotope dilution mass spectrometry and standard addition techniques were developed for the analysis of four elements (Ca, As, Cd and Pb) in a mushroom powder material. Results from the validated methods were compared to those of other national metrology institutes in the CCQM-K89 intercomparisons and the results were in excellent agreement with the reference values. The same methods were then used for the assignment of reference values to a mushroom powder Certified Reference Material (CRM). The certified values obtained for Ca, As, Cd and Pb were 1.444 ± 0.099 mg/g, 5.61 ± 0.59 mg/kg, 1.191 ± 0.079 mg/kg and 5.23 ± 0.94 mg/kg, respectively. The expanded measurement uncertainties were obtained by combining the uncertainty contributions from characterization (uchar) and between-bottle homogeneity (ubb). Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Preparation and certification of Re-Os dating reference materials: Molybdenites HLP and JDC

    USGS Publications Warehouse

    Du, A.; Wu, S.; Sun, D.; Wang, Shaoming; Qu, W.; Markey, R.; Stain, H.; Morgan, J.; Malinovskiy, D.

    2004-01-01

    Two Re-Os dating reference material molybdenites were prepared. Molybdenite JDC and molybdenite HLP are from a carbonate vein-type molybdenum-(lead)- uranium deposit in the Jinduicheng-Huanglongpu area of Shaanxi province, China. The samples proved to be homogeneous, based on the coefficient of variation of analytical results and an analysis of variance test. The sampling weight was 0.1 g for JDC and 0.025 g for HLP. An isotope dilution method was used for the determination of Re and Os. Sample decomposition and preconcentration of Re and Os prior to measurement were accomplished using a variety of methods: acid digestion, alkali fusion, ion exchange and solvent extraction. Negative thermal ionisation mass spectrometry and inductively coupled plasma-mass spectrometry were used for the determination of Re and 187Os concentration and isotope ratios. The certified values include the contents of Re and Os and the model ages. For HLP, the Re content was 283.8 ?? 6.2 ??g g-1, 187Os was 659 ?? 14 ng g-1 and the Re-Os model age was 221.4 ?? 5.6 Ma. For JDC, the Re content was 17.39 ?? 0.32 ng g-1, 187Os was 25.46 ?? 0.60 ng g-1 and the Re-Os model age was 139.6 ?? 3.8 Ma. Uncertainties for both certified reference materials are stated at the 95% level of confidence. Three laboratories (from three countries: P.R. China, USA, Sweden) joined in the certification programme. These certified reference materials are primarily useful for Re-Os dating of molybdenite, sulfides, black shale, etc.

  8. 30 CFR 250.198 - Documents incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Conditions, May 2007; incorporated by reference at § 250.901; (3) API Bulletin 2INT-EX, Interim Guidance for...; incorporated by reference at § 250.1202; (34) API MPMS, Chapter 11.1—Volume Correction Factors, Volume 1, Table...; (35) API MPMS, Chapter 11.2.2—Compressibility Factors for Hydrocarbons: 0.350-0.637 Relative Density...

  9. 30 CFR 250.198 - Documents incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Conditions, May 2007; incorporated by reference at § 250.901; (3) API Bulletin 2INT-EX, Interim Guidance for...; incorporated by reference at § 250.1202; (34) API MPMS, Chapter 11.1—Volume Correction Factors, Volume 1, Table...; (35) API MPMS, Chapter 11.2.2—Compressibility Factors for Hydrocarbons: 0.350-0.637 Relative Density...

  10. New Ca-Tims and La-Icp Analyses of GJ-1, Plesovice, and FC1 Reference Materials

    NASA Astrophysics Data System (ADS)

    Feldman, J. D.; Möller, A.; Walker, J. D.

    2014-12-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) U-Pb zircon geochronology relies on external reference standards to monitor and correct for different mass fractionation effects and instrument drift. Common zircon reference materials used within the community, including the KU Isotope Geochemistry Laboratory, are GJ-1 (207Pb/206Pb age: 608.53 +/- 0.37Ma; Jackson et al., 2004), Plesovice (337.13 +/- 0.37 Ma; Slama et al., 2008), and FC-1 (1099.0 +/-0.6 Ma; Paces and Miller, 1993). The age distribution of zircon reference material varies slightly from sample fraction to sample fraction, and the published results for GJ-1 are slightly discordant. As a result, using the published data for the distributed standard splits can lead to small systematic variations when comparing datasets from different labs, and more high precision data are needed to evaluate potential inhomogeneity of sample splits used in different laboratories. Here we characterize these reference materials with cathodoluminescence, LA-ICP-MS traverses across grains, and high precision CA-TIMS to better constrain the ages and assess zoning of these standards, and present the data for comparison with other laboratories. Reducing systematic error by dating our own reference material lends confidence to our analyses and allows for inter-laboratory age reproducibility of unknowns. Additionally, the reduction in propagated uncertainties (especially in GJ-1, for which both the red and yellow variety will be analyzed) will be used to improve long-term reproducibility, comparisons between samples of similar age, detrital populations and composite pluton zircons. Jackson, S.E., et al., 2004, Chemical Geology, v. 211, p. 47-69. Paces, J.B. & Miller, J.D., 1993, Journal of Geophysical Research, v. 80, p. 13997-14013. Slama, J., et al., 2008, Chemical Geology, v. 249. p. 1-35.

  11. Energetics of Table Tennis and Table Tennis-Specific Exercise Testing.

    PubMed

    Zagatto, Alessandro Moura; Leite, Jorge Vieira de Mello; Papoti, Marcelo; Beneke, Ralph

    2016-11-01

    To test the hypotheses that the metabolic profile of table tennis is dominantly aerobic, anaerobic energy is related to the accumulated duration and intensity of rallies, and activity and metabolic profile are interrelated with the individual fitness profile determined via table tennis-specific tests. Eleven male experienced table tennis players (22 ± 3 y, 77.6 ± 18.9 kg, 177.1 ± 8.1 cm) underwent 2 simulated table tennis matches to analyze aerobic (W OXID ) energy, anaerobic glycolytic (W BLC ) energy, and phosphocreatine breakdown (W PCr ); a table tennis-specific graded exercise test to measure ventilatory threshold and peak oxygen uptake; and an exhaustive supramaximal table tennis effort to determine maximal accumulated deficit of oxygen. W OXID , W BLC , and W PCr corresponded to 96.5% ± 1.7%, 1.0% ± 0.7%, and 2.5% ± 1.4%, respectively. W OXID was interrelated with rally duration (r = .81) and number of shots per rally (r = .77), whereas match intensity was correlated with WPCr (r = .62) and maximal accumulated oxygen deficit (r = .58). The metabolic profile of table tennis is predominantly aerobic and interrelated with the individual fitness profile determined via table tennis-specific tests. Table tennis-specific ventilatory threshold determines the average oxygen uptake and overall W OXID , whereas table tennis-specific maximal accumulated oxygen deficit indicates the ability to use and sustain slightly higher blood lactate concentration and W BLC during the match.

  12. Development of a Genomic DNA Reference Material Panel for Myotonic Dystrophy Type 1 (DM1) Genetic Testing

    PubMed Central

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E.; Luebbe, Elizabeth A.; Moxley, Richard T.; Toji, Lorraine

    2014-01-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3′ untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. PMID:23680132

  13. The Ability of Elite Table Tennis Players with Intellectual Disabilities to Adapt Their Service/Return

    ERIC Educational Resources Information Center

    Van Biesen, Debbie; Verellen, Joeri; Meyer, Christophe; Mactavish, Jennifer; Van de Vliet, Peter; Vanlandewijck, Yves

    2010-01-01

    In this study the ability of elite table tennis players with intellectual disability (ID) to adapt their service/return to specific ball spin characteristics was investigated. This was done by examining the performance of 39 players with ID and a reference group of 8 players without ID on a standardized table tennis specific test battery. The…

  14. Superconductivity theory applied to the periodic table of the elements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elifritz, T.L.

    1994-12-31

    The modern theory of superconductivity, based upon the BCS to Bose-Einstein transition, is applied to the periodic table of the elements, in order to isolate the essential features of high temperature superconductivity and to predict its occurrence within the periodic table. It is predicted that Sodium-Ammonia, Sodium Zinc Phosphide and Bismuth (I) Iodide are promising materials for experimental explorations of high temperature superconductivity.

  15. Superconductivity theory applied to the periodic table of the elements

    NASA Technical Reports Server (NTRS)

    Elifritz, Thomas Lee

    1995-01-01

    The modern theory of superconductivity, based upon the BCS to Bose-Einstein transition is applied to the periodic table of the elements, in order to isolate the essential features of of high temperature superconductivity and to predict its occurrence with the periodic table. It is predicted that Sodium-Ammonia, Sodium Zinc Phosphide and Bismuth (I) Iodide are promising materials for experimental explorations of high temperature superconductivity.

  16. Reference manual for data base on Nevada well logs

    USGS Publications Warehouse

    Bauer, E.M.; Cartier, K.D.

    1995-01-01

    The U.S. Geological Survey and Nevada Division of Water Resources are cooperatively using a data base for are cooperatively using a data base for managing well-log information for the State of Nevada. The Well-Log Data Base is part of an integrated system of computer data bases using the Ingres Relational Data-Base Management System, which allows efficient storage and access to water information from the State Engineer's office. The data base contains a main table, two ancillary tables, and nine lookup tables, as well as a menu-driven system for entering, updating, and reporting on the data. This reference guide outlines the general functions of the system and provides a brief description of data tables and data-entry screens.

  17. Reference Material Kydex(registered trademark)-100 Test Data Message for Flammability Testing

    NASA Technical Reports Server (NTRS)

    Engel, Carl D.; Richardson, Erin; Davis, Eddie

    2003-01-01

    The Marshall Space Flight Center (MSFC) Materials and Processes Technical Information System (MAPTIS) database contains, as an engineering resource, a large amount of material test data carefully obtained and recorded over a number of years. Flammability test data obtained using Test 1 of NASA-STD-6001 is a significant component of this database. NASA-STD-6001 recommends that Kydex 100 be used as a reference material for testing certification and for comparison between test facilities in the round-robin certification testing that occurs every 2 years. As a result of these regular activities, a large volume of test data is recorded within the MAPTIS database. The activity described in this technical report was undertaken to mine the database, recover flammability (Test 1) Kydex 100 data, and review the lessons learned from analysis of these data.

  18. 41 CFR 102-117.170 - What reference materials are available to ship freight?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... are available to ship freight? 102-117.170 Section 102-117.170 Public Contracts and Property... TRANSPORTATION 117-TRANSPORTATION MANAGEMENT Shipping Freight § 102-117.170 What reference materials are available to ship freight? (a) The following is a partial list of handbooks and guides available from GSA...

  19. 41 CFR 102-117.170 - What reference materials are available to ship freight?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... are available to ship freight? 102-117.170 Section 102-117.170 Public Contracts and Property... TRANSPORTATION 117-TRANSPORTATION MANAGEMENT Shipping Freight § 102-117.170 What reference materials are available to ship freight? (a) The following is a partial list of handbooks and guides available from GSA...

  20. 41 CFR 102-117.170 - What reference materials are available to ship freight?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... are available to ship freight? 102-117.170 Section 102-117.170 Public Contracts and Property... TRANSPORTATION 117-TRANSPORTATION MANAGEMENT Shipping Freight § 102-117.170 What reference materials are available to ship freight? (a) The following is a partial list of handbooks and guides available from GSA...

  1. 41 CFR 102-117.170 - What reference materials are available to ship freight?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... are available to ship freight? 102-117.170 Section 102-117.170 Public Contracts and Property... TRANSPORTATION 117-TRANSPORTATION MANAGEMENT Shipping Freight § 102-117.170 What reference materials are available to ship freight? (a) The following is a partial list of handbooks and guides available from GSA...

  2. 41 CFR 102-117.170 - What reference materials are available to ship freight?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... are available to ship freight? 102-117.170 Section 102-117.170 Public Contracts and Property... TRANSPORTATION 117-TRANSPORTATION MANAGEMENT Shipping Freight § 102-117.170 What reference materials are available to ship freight? (a) The following is a partial list of handbooks and guides available from GSA...

  3. Contrast material-enhanced, moving-table MR angiography versus digital subtraction angiography for surveillance of peripheral arterial bypass grafts.

    PubMed

    Loewe, Christian; Cejna, Manfred; Schoder, Maria; Loewe-Grgurin, Maria; Wolf, Florian; Lammer, Johannes; Thurnher, Siegfried A

    2003-09-01

    To assess the accuracy of moving-table MR angiography (MRA) in the evaluation of peripheral bypass grafts. There were 39 patients who had had peripheral bypass graft surgery and then subsequently underwent digital subtraction angiography (DSA) and contrast material-enhanced MRA, which was performed with moving-table software on a 1.0-T system before and during administration of 40 mL gadolinium. For evaluation, every bypass graft was divided into three parts and every leg into 14 segments. Disease severity was scored in four categories (0%-29%, 30%-69%, 70%-99%, 100%). Results were compared with those of the DSA. A total of 147 bypass graft segments and 938 vessel segments were classified. In 132 of the assessable 147 bypass segments, disease gradings with both methods were congruent; however, 13 stenoses were misinterpreted by MRA for one grade and two additional lesions by two grades, leading to an accuracy in precise stenoses detection of 89.9%. The sensitivity and specificity values in the detection of bypass graft stenoses >69% (grade 3 + 4 lesions) reached 90.0% and 98.3%, respectively. In 821 of 938 vessel segments the accuracy of MRA in stenoses detection reached 87.5%. The sensitivity and specificity values in the detection of grade 3 + 4 lesions were 95.6% and 94.0% for the native vessels, respectively. Moving-table MRA was as accurate in assessing bypass grafts as it was for the native arteries and showed a great accuracy in stenosis detection compared with DSA. Therefore, MRA is a promising modality for bypass graft surveillance and might be a noninvasive alternative to DSA in this regard.

  4. 40 CFR Table 2 to Subpart Ggggg of... - Control Levels as Required by § 63.7895(a) for Tanks Managing Remediation Material With a Maximum...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....7895(a) for Tanks Managing Remediation Material With a Maximum HAP Vapor Pressure Less Than 76.6 kPa 2 Table 2 to Subpart GGGGG of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Site Remediation Pt. 63...

  5. 40 CFR Table 2 to Subpart Ggggg of... - Control Levels as Required by § 63.7895(a) for Tanks Managing Remediation Material With a Maximum...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....7895(a) for Tanks Managing Remediation Material With a Maximum HAP Vapor Pressure Less Than 76.6 kPa 2 Table 2 to Subpart GGGGG of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Site Remediation Pt. 63...

  6. 40 CFR Table 2 to Subpart Ggggg of... - Control Levels as Required by § 63.7895(a) for Tanks Managing Remediation Material With a Maximum...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....7895(a) for Tanks Managing Remediation Material With a Maximum HAP Vapor Pressure Less Than 76.6 kPa 2 Table 2 to Subpart GGGGG of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Site Remediation Pt. 63...

  7. 40 CFR Table 2 to Subpart Ggggg of... - Control Levels as Required by § 63.7895(a) for Tanks Managing Remediation Material With a Maximum...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....7895(a) for Tanks Managing Remediation Material With a Maximum HAP Vapor Pressure Less Than 76.6 kPa 2 Table 2 to Subpart GGGGG of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Site Remediation Pt. 63...

  8. Determination of perfluorinated alkyl acid concentrations in human serum and milk standard reference materials.

    PubMed

    Keller, Jennifer M; Calafat, Antonia M; Kato, Kayoko; Ellefson, Mark E; Reagen, William K; Strynar, Mark; O'Connell, Steven; Butt, Craig M; Mabury, Scott A; Small, Jeff; Muir, Derek C G; Leigh, Stefan D; Schantz, Michele M

    2010-05-01

    Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.

  9. The production and certification of a plutonium equal-atom reference material: NBL CRM 128

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, D.W.; Gradle, C.G.; Soriano, M.D.

    This report describes the design, production, and certification of the New Brunswick Laboratory plutonium equal-atom certified reference material (CRM), NBL CRM 128. The primary use of this CRM is for the determination of bias corrections encountered in the operation of a mass spectrometer. This reference material is available to the US Department of Energy contractor-operated and government-operated laboratories, as well as to the international nuclear safeguards community. The absolute, or unbiased, certified value for the CRM's Pu-242/Pu-239 ratio is 1.00063 {plus minus} 0.00026 (95% confidence interval) as of October 1, 1984. This value was obtained through the quantitative blending ofmore » high-purity, chemically and isotopically characterized separated isotopes, as well as through intercomparisons of CRM samples with calibration mixtures using thermal ionization mass spectrometry. 32 tabs.« less

  10. CRISPR/Cas9 Technology-Based Xenograft Tumors as Candidate Reference Materials for Multiple EML4-ALK Rearrangements Testing.

    PubMed

    Peng, Rongxue; Zhang, Rui; Lin, Guigao; Yang, Xin; Li, Ziyang; Zhang, Kuo; Zhang, Jiawei; Li, Jinming

    2017-09-01

    The echinoderm microtubule-associated protein-like 4 and anaplastic lymphoma kinase (ALK) receptor tyrosine kinase (EML4-ALK) rearrangement is an important biomarker that plays a pivotal role in therapeutic decision making for non-small-cell lung cancer (NSCLC) patients. Ensuring accuracy and reproducibility of EML4-ALK testing by fluorescence in situ hybridization, immunohistochemistry, RT-PCR, and next-generation sequencing requires reliable reference materials for monitoring assay sensitivity and specificity. Herein, we developed novel reference materials for various kinds of EML4-ALK testing. CRISPR/Cas9 was used to edit various NSCLC cell lines containing EML4-ALK rearrangement variants 1, 2, and 3a/b. After s.c. inoculation, the formalin-fixed, paraffin-embedded (FFPE) samples from xenografts were prepared and tested for suitability as candidate reference materials by fluorescence in situ hybridization, immunohistochemistry, RT-PCR, and next-generation sequencing. Sample validation and commutability assessments showed that all types of FFPE samples derived from xenograft tumors have typical histological structures, and EML4-ALK testing results were similar to the clinical ALK-positive NSCLC specimens. Among the four methods for EML4-ALK detection, the validation test showed 100% concordance. Furthermore, these novel FFPE reference materials showed good stability and homogeneity. Without limitations on variant types and production, our novel FFPE samples based on CRISPR/Cas9 editing and xenografts are suitable as candidate reference materials for the validation, verification, internal quality control, and proficiency testing of EML4-ALK detection. Copyright © 2017 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  11. Incorporating water table dynamics in climate modeling: 1. Water table observations and equilibrium water table simulations

    NASA Astrophysics Data System (ADS)

    Fan, Ying; Miguez-Macho, Gonzalo; Weaver, Christopher P.; Walko, Robert; Robock, Alan

    2007-05-01

    Soil moisture is a key participant in land-atmosphere interactions and an important determinant of terrestrial climate. In regions where the water table is shallow, soil moisture is coupled to the water table. This paper is the first of a two-part study to quantify this coupling and explore its implications in the context of climate modeling. We examine the observed water table depth in the lower 48 states of the United States in search of salient spatial and temporal features that are relevant to climate dynamics. As a means to interpolate and synthesize the scattered observations, we use a simple two-dimensional groundwater flow model to construct an equilibrium water table as a result of long-term climatic and geologic forcing. Model simulations suggest that the water table depth exhibits spatial organization at watershed, regional, and continental scales, which may have implications for the spatial organization of soil moisture at similar scales. The observations suggest that water table depth varies at diurnal, event, seasonal, and interannual scales, which may have implications for soil moisture memory at these scales.

  12. 40 CFR Table E-2 to Subpart E of... - Spectral Energy Distribution and Permitted Tolerance for Conducting Radiative Tests

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Permitted Tolerance for Conducting Radiative Tests E Table E-2 to Subpart E of Part 53 Protection of... Reference Methods and Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 Pt. 53, Subpt. E, Table E-2 Table E-2 to Subpart E of Part 53—Spectral Energy Distribution and Permitted Tolerance for...

  13. Development of a genomic DNA reference material panel for myotonic dystrophy type 1 (DM1) genetic testing.

    PubMed

    Kalman, Lisa; Tarleton, Jack; Hitch, Monica; Hegde, Madhuri; Hjelm, Nick; Berry-Kravis, Elizabeth; Zhou, Lili; Hilbert, James E; Luebbe, Elizabeth A; Moxley, Richard T; Toji, Lorraine

    2013-07-01

    Myotonic dystrophy type 1 (DM1) is caused by expansion of a CTG triplet repeat in the 3' untranslated region of the DMPK gene that encodes a serine-threonine kinase. Patients with larger repeats tend to have a more severe phenotype. Clinical laboratories require reference and quality control materials for DM1 diagnostic and carrier genetic testing. Well-characterized reference materials are not available. To address this need, the Centers for Disease Control and Prevention-based Genetic Testing Reference Material Coordination Program, in collaboration with members of the genetic testing community, the National Registry of Myotonic Dystrophy and Facioscapulohumeral Muscular Dystrophy Patients and Family Members, and the Coriell Cell Repositories, has established and characterized cell lines from patients with DM1 to create a reference material panel. The CTG repeats in genomic DNA samples from 10 DM1 cell lines were characterized in three clinical genetic testing laboratories using PCR and Southern blot analysis. DMPK alleles in the samples cover four of five DM1 clinical categories: normal (5 to 34 repeats), mild (50 to 100 repeats), classical (101 to 1000 repeats), and congenital (>1000 repeats). We did not identify or establish Coriell cell lines in the premutation range (35 to 49 repeats). These samples are publicly available for quality control, proficiency testing, test development, and research and should help improve the accuracy of DM1 testing. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  14. REFERENCE MATERIALS AND QUALITY ASSURANCE FOR THE CHARACTERIZATION OF ORGANIC COMPOUNDS IN PARTICULATE MATTER

    EPA Science Inventory

    One of the first environmental matrix Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST) for determination of organic species was SRM 1649 Urban Dust, ambient total suspended particulate matter (PM) collected in Washington D...

  15. Reference materials for cellular therapeutics.

    PubMed

    Bravery, Christopher A; French, Anna

    2014-09-01

    The development of cellular therapeutics (CTP) takes place over many years, and, where successful, the developer will anticipate the product to be in clinical use for decades. Successful demonstration of manufacturing and quality consistency is dependent on the use of complex analytical methods; thus, the risk of process and method drift over time is high. The use of reference materials (RM) is an established scientific principle and as such also a regulatory requirement. The various uses of RM in the context of CTP manufacturing and quality are discussed, along with why they are needed for living cell products and the analytical methods applied to them. Relatively few consensus RM exist that are suitable for even common methods used by CTP developers, such as flow cytometry. Others have also identified this need and made proposals; however, great care will be needed to ensure any consensus RM that result are fit for purpose. Such consensus RM probably will need to be applied to specific standardized methods, and the idea that a single RM can have wide applicability is challenged. Written standards, including standardized methods, together with appropriate measurement RM are probably the most appropriate way to define specific starting cell types. The characteristics of a specific CTP will to some degree deviate from those of the starting cells; consequently, a product RM remains the best solution where feasible. Each CTP developer must consider how and what types of RM should be used to ensure the reliability of their own analytical measurements. Copyright © 2014 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  16. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications C Table C-1 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges...

  17. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications C Table C-1 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges...

  18. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications C Table C-1 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges...

  19. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specifications C Table C-1 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges...

  20. Polychlorinated biphenyls (PCB), chlorinated pesticides, and polycyclic aromatic hydrocarbons (PAHs) in environmental standard reference materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poster, D.L.; Schantz, M.M.; Parris, R.M.

    1995-12-31

    Standard reference materials (SRMs) are certified reference materials issued by the National Institute of Standards and Technology (NIST). Natural matrix environmental sample SRMs have been developed the Analytical Chemistry Division to assist in validating measurements for organic contaminants in the environment. Many of these are well characterized for contaminants such as polychlorinated biphenyls (PCBs), chlorinated pesticides, and polycyclic aromatic hydrocarbons (PAHs). SRM 1649, Organics in Urban Dust, is currently available with certified concentrations for 5 PAHs but because of the widespread use of this material in air pollution monitoring programs and to expand the usefulness of this material, the authorsmore » are further characterizing the material for a larger number of PAHs as well as PCBs and chlorinated pesticides. They will also soon issue a diesel particulate extract (SRM 1975) that is well characterized for PAHS, including many nitrogen substituted compounds. In addition to natural matrix materials, solutions useful for calibrating chromatographic detector response factors and retention times, and spiking sample blanks for determination of analyte recoveries, are also available. Solution SRMs currently available contain PCS congeners, chlorinated pesticides, and PAHs. New solution SRMs in preparation will contain additional chlorinated pesticides, PCB congeners (e.g., non-ortho substituted chlorobiphenyls), and perdeuterated PAHs. Recent SRM work will be presented with particular attention on the methods used for determining organic contaminant concentrations in the urban dust material and in the diesel particulate extract.« less

  1. The role of adequate reference materials in density measurements in hemodialysis

    NASA Astrophysics Data System (ADS)

    Furtado, A.; Moutinho, J.; Moura, S.; Oliveira, F.; Filipe, E.

    2015-02-01

    In hemodialysis, oscillation-type density meters are used to measure the density of the acid component of the dialysate solutions used in the treatment of kidney patients. An incorrect density determination of this solution used in hemodialysis treatments can cause several and adverse events to patients. Therefore, despite the Fresenius Medical Care (FME) tight control of the density meters calibration results, this study shows the benefits of mimic the matrix usually measured to produce suitable reference materials for the density meter calibrations.

  2. Development of benzene, toluene, ethylbenzene and xylenes certified gaseous reference materials

    NASA Astrophysics Data System (ADS)

    Brum, M. C.; Sobrinho, D. C. G.; Fagundes, F. A.; Oudwater, R. J.; Augusto, C. R.

    2016-07-01

    The work describes the production of certified gaseous reference materials of benzene, toluene, ethylbenzene and xylenes (BTEX) in nitrogen from the gravimetric production up to the long term stability tests followed by the certifying step. The uncertainty in the amount fractions of the compounds in these mixtures was approximately 4% (relative) for the range studied from 2 to 16 µmol/mol. Also the adsorption of the BTEX on the cylinder surface and the tubing were investigated as potential uncertainty source.

  3. Reference Materials for Trace Element Microanalysis of Carbonates by SIMS and other Mass Spectrometric Techniques

    NASA Astrophysics Data System (ADS)

    Layne, G. D.

    2009-12-01

    Today, many areas of geochemical research utilize microanalytical determinations of trace elements in carbonate minerals. In particular, there has been an explosion in the application of Secondary Ion Mass Spectrometry (SIMS) to studies of marine biomineralization. SIMS provides highly precise determinations of Mg and Sr at the concentration levels normally encountered in corals, mollusks or fish otoliths. It is also a highly effective means for determining a wide range of other trace elements at ppm levels (e.g., Na, Fe, Mn, Ba, REE, Pb, Th, and U) in a variety of naturally occurring calcite and aragonite matrices - and so is potentially valuable in studies of diagenesis, hydrothermal fluids and carbonatitic magmas. For SIMS, modest time per spot (often <5 min), lateral spatial resolution (<10 μm), sample volume consumption (<10 ng) and overall reproducibility compare extremely favorably with other microanalytical techniques for these applications. However, accuracy and reproducibility are currently wholly limited by the homogeneity of available solid reference material - which is far inferior to the tenths of a percent levels of precision achieved by SIMS. Due to variation in the sputtered ion yields of most elements with the major element composition of the sample matrix, accuracy of SIMS depends intimately on matrix-matched solid reference materials. Despite its rapidly increasing use for trace element analyses of carbonates, there remains a dearth of certified reference materials suitable for calibrating SIMS. The pressed powders used by some analysts to calibrate LA-ICP-MS do not perform well for SIMS - they are not perfectly dense or homogeneous to the desired level at the micron scale of sampling. Further, they often prove incompatible with the sample high vacuum compatibility requirement for stable SIMS analysis (10-8 to 10-9 torr). Some naturally occurring calcite has apparent utility as a reference material. For example, equigranular calcite from some

  4. Nicotine, acetanilide and urea multi-level2H-,13C- and15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry

    USGS Publications Warehouse

    Schimmelmann, A.; Albertino, A.; Sauer, P.E.; Qi, H.; Molinie, R.; Mesnard, F.

    2009-01-01

    Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the S values of these reference materials should bracket the isotopic range of samples with unknown S values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for ??13C and ??13N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: ??2Hnicotine -162 to -45%o, ??13Cnicotine -30.05 to +7.72%, ?? 15Nnicotine -6.03 to +33.62%; ??15N acetanilide +1-18 to +40.57%; ??13Curea -34.13 to +11.71%, ??15Nurea +0.26 to +40.61% (recommended ?? values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different ??13N

  5. Pivot tables for mortality analysis, or who needs life tables anyway?

    PubMed

    Wesley, David; Cox, Hugh F

    2007-01-01

    Actuarial life-table analysis has long been used by life insurance medical directors for mortality abstraction from clinical studies. Ironically, today's life actuary instead uses pivot tables to analyze mortality. Pivot tables (a feature/function in MS Excel) collapse various dimensions of data that were previously arranged in an "experience study" format. Summary statistics such as actual deaths, actual and expected mortality (usually measured in dollars), and calculated results such as actual to expected ratios, are then displayed in a 2-dimensional grid. The same analytic process, excluding the dollar focus, can be used for clinical mortality studies. For raw survival data, especially large datasets, this combination of experience study data and pivot tables has clear advantages over life-table analysis in both accuracy and flexibility. Using the SEER breast cancer data, we compare the results of life-table analysis and pivot-table analysis.

  6. Preparation of an in-house reference material containing fumonisins in Thai rice and matrix extension of the analytical method for Japanese rice.

    PubMed

    Awaludin, Norhafniza; Nagata, Reiko; Kawasaki, Tomomi; Kushiro, Masayo

    2009-12-01

    Mycotoxin contamination in rice is less reported, compared to that in wheat or maize, however, some Fusarium fungi occasionally infect rice in the paddy field. Fumonisins are mycotoxins mainly produced by Fusarium verticillioides, which often ruins maize. Rice adherent fungus Gibberella fujikuroi is taxonomically near to F. verticillioides, and there are sporadic reports of fumonisin contamination in rice from Asia, Europe and the United States. Therefore, there exists the potential risk of fumonisin contamination in rice as well as the need for the validated analytical method for fumonisins in rice. Although both natural and spiked reference materials are available for some Fusarium mycotoxins in matrices of wheat and maize, there are no reference materials for Fusarium mycotoxins in rice. In this study, we have developed a method for the preparation of a reference material containing fumonisins in Thai rice. A ShakeMaster grinding machine was used for the preparation of a mixed material of blank Thai rice and F. verticillioides-infected Thai rice. The homogeneity of the mixed material was confirmed by one-way analysis of variance, which led this material to serve as an in-house reference material. Using this reference material, several procedures to extract fumonisins from Thai rice were compared. Accordingly, we proved the applicability of an effective extraction procedure for the determination of fumonisins in Japanese rice.

  7. Preparation of an In-House Reference Material Containing Fumonisins in Thai Rice and Matrix Extension of the Analytical Method for Japanese Rice

    PubMed Central

    Awaludin, Norhafniza; Nagata, Reiko; Kawasaki, Tomomi; Kushiro, Masayo

    2009-01-01

    Mycotoxin contamination in rice is less reported, compared to that in wheat or maize, however, some Fusarium fungi occasionally infect rice in the paddy field. Fumonisins are mycotoxins mainly produced by Fusarium verticillioides, which often ruins maize. Rice adherent fungus Gibberella fujikuroi is taxonomically near to F. verticillioides, and there are sporadic reports of fumonisin contamination in rice from Asia, Europe and the United States. Therefore, there exists the potential risk of fumonisin contamination in rice as well as the need for the validated analytical method for fumonisins in rice. Although both natural and spiked reference materials are available for some Fusarium mycotoxins in matrices of wheat and maize, there are no reference materials for Fusarium mycotoxins in rice. In this study, we have developed a method for the preparation of a reference material containing fumonisins in Thai rice. A ShakeMaster grinding machine was used for the preparation of a mixed material of blank Thai rice and F. verticillioides-infected Thai rice. The homogeneity of the mixed material was confirmed by one-way analysis of variance, which led this material to serve as an in-house reference material. Using this reference material, several procedures to extract fumonisins from Thai rice were compared. Accordingly, we proved the applicability of an effective extraction procedure for the determination of fumonisins in Japanese rice. PMID:22069540

  8. Applications of New Synthetic Uranium Reference Materials for Research in Geochemistry

    NASA Astrophysics Data System (ADS)

    Richter, Stephan; Alonso, Adolfo; Aregbe, Yetunde; Eykens, Roger; Jacobsson, Ulf; Kuehn, Heinz; Verbruggen, Andre; Weyer, Stefan

    2010-05-01

    For many applications in geochemistry research isotope ratio measurements play a significant role. In geochronology isotope abundances of uranium and its daughter products thorium and lead are being used to determine the age and history of various samples of geological interest. For measuring the isotopic compositions of these elements by mass spectrometry, suitable isotope reference materials are needed to validate measurement procedures and to calibrate multi-collector and ion counting detector systems. IRMM is a recognized provider for nuclear isotope reference materials to the nuclear industry and nuclear safeguards authorities, which are also being applied widely for geochemical applications. Firstly, the double spike IRMM-3636 with a 233U/236U ratio of 1:1 was prepared which allows internal mass fractionation correction for high precision 235U/238U ratio measurements. The 234U abundance of this double spike material is low enough to allow an accurate and precise correction of 234U/238U ratios, even for measurements of close to equilibrium uranium samples. The double spike IRMM-3636 is offered in 3 concentrations: 1mg/g, 0.1mg/g and 0.005mg/g. Secondly, the 236U single spike IRMM-3660 was prepared and is offered in 3 concentrations: 1mg/g, 0.1mg/g and 0.01mg/g. Thirdly, a "Quad"-isotope reference material, IRMM-3101, has been prepared which is characterized by 233U/235U/236U/238U=1/1/1/1. This material is useful for checking Faraday cup efficiencies and inter-calibration of MIC (multiple ion counting) detectors. The quad-IRM is offered in 3 concentrations: 1mg/g, 0.1mg/g and 0.01mg/g. As one example for the significant influence of synthetic reference materials for geochemical research, the IRMM-074 series of gravimetrically prepared uranium mixtures for linearity testing of secondary electron multipliers (SEMs) has been applied for the redetermination of the secular equilibrium 234U/238U value and the 234U half-life by Cheng et al (2009). Due to the use of

  9. Results of a Saxitoxin Proficiency Test Including Characterization of Reference Material and Stability Studies

    PubMed Central

    Harju, Kirsi; Rapinoja, Marja-Leena; Avondet, Marc-André; Arnold, Werner; Schär, Martin; Luginbühl, Werner; Kremp, Anke; Suikkanen, Sanna; Kankaanpää, Harri; Burrell, Stephen; Söderström, Martin; Vanninen, Paula

    2015-01-01

    A saxitoxin (STX) proficiency test (PT) was organized as part of the Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk (EQuATox) project. The aim of this PT was to provide an evaluation of existing methods and the European laboratories’ capabilities for the analysis of STX and some of its analogues in real samples. Homogenized mussel material and algal cell materials containing paralytic shellfish poisoning (PSP) toxins were produced as reference sample matrices. The reference material was characterized using various analytical methods. Acidified algal extract samples at two concentration levels were prepared from a bulk culture of PSP toxins producing dinoflagellate Alexandrium ostenfeldii. The homogeneity and stability of the prepared PT samples were studied and found to be fit-for-purpose. Thereafter, eight STX PT samples were sent to ten participating laboratories from eight countries. The PT offered the participating laboratories the possibility to assess their performance regarding the qualitative and quantitative detection of PSP toxins. Various techniques such as official Association of Official Analytical Chemists (AOAC) methods, immunoassays, and liquid chromatography-mass spectrometry were used for sample analyses. PMID:26602927

  10. Determination of the purity of pharmaceutical reference materials by 1H NMR using the standardless PULCON methodology.

    PubMed

    Monakhova, Yulia B; Kohl-Himmelseher, Matthias; Kuballa, Thomas; Lachenmeier, Dirk W

    2014-11-01

    A fast and reliable nuclear magnetic resonance spectroscopic method for quantitative determination (qNMR) of targeted molecules in reference materials has been established using the ERETIC2 methodology (electronic reference to access in vivo concentrations) based on the PULCON principle (pulse length based concentration determination). The developed approach was validated for the analysis of pharmaceutical samples in the context of official medicines control, including ibandronic acid, amantadine, ambroxol and lercanidipine. The PULCON recoveries were above 94.3% and coefficients of variation (CVs) obtained by quantification of different targeted resonances ranged between 0.7% and 2.8%, demonstrating that the qNMR method is a precise tool for rapid quantification (approximately 15min) of reference materials and medicinal products. Generally, the values were within specification (certified values) provided by the manufactures. The results were in agreement with NMR quantification using an internal standard and validated reference HPLC analysis. The PULCON method was found to be a practical alternative with competitive precision and accuracy to the classical internal reference method and it proved to be applicable to different solvent conditions. The method can be recommended for routine use in medicines control laboratories, especially when the availability and costs of reference compounds are problematic. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. 46 CFR 150.140 - Cargoes not listed in Table I or II.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Cargoes not listed in Table I or II. 150.140 Section 150.140 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES COMPATIBILITY OF CARGOES § 150.140 Cargoes not listed in Table I or II. A cargo of hazardous material not listed...

  12. 46 CFR 150.140 - Cargoes not listed in Table I or II.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Cargoes not listed in Table I or II. 150.140 Section 150.140 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES COMPATIBILITY OF CARGOES § 150.140 Cargoes not listed in Table I or II. A cargo of hazardous material not listed...

  13. 46 CFR 150.140 - Cargoes not listed in Table I or II.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Cargoes not listed in Table I or II. 150.140 Section 150.140 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES COMPATIBILITY OF CARGOES § 150.140 Cargoes not listed in Table I or II. A cargo of hazardous material not listed...

  14. 46 CFR 150.140 - Cargoes not listed in Table I or II.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Cargoes not listed in Table I or II. 150.140 Section 150.140 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES COMPATIBILITY OF CARGOES § 150.140 Cargoes not listed in Table I or II. A cargo of hazardous material not listed...

  15. 46 CFR 150.140 - Cargoes not listed in Table I or II.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Cargoes not listed in Table I or II. 150.140 Section 150.140 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES COMPATIBILITY OF CARGOES § 150.140 Cargoes not listed in Table I or II. A cargo of hazardous material not listed...

  16. Database of natural matrix reference materials (NMRM) for organic constituents.

    PubMed

    Iyengar, G V; Bleise, A R

    2001-06-01

    The International Atomic Energy Agency maintains a database of internationally available certified reference materials (CRM) of natural matrices. This database is periodically updated, and presently documents nearly 25,000 measurands in 1,700 materials. The organic constituents are classified in five major groups of analytes aliphatic and aromatic hydrocarbons (A), chlorinated hydrocarbons (B), pesticides (C), organometallic compounds (D) and other organic constituents (nutrients, etc.) (E). The matrices include natural materials such as body fluids, food products, soils, and sediments, terrestrial (e.g. plants), and anthropogenic products (e.g. dust, fly ash). These five organic groups of analytes encompass more than 2000 measurands for 420 different analytes in 230 materials. Of these measurands, 1,682 (68%) are certified, and 768 (32%) are provided as informational values. Within each major group of analytes, measurands reported as informational values accounted for: A (35%); B (35%); C (26%); D (10%), and E (22%). The high proportion of informational values (i.e. non-certified values) for A, B, and C, compares well with a similar but undesirable situation faced in the nineteen-seventies in the inorganic area when simultaneous multielement techniques became available. In the case of D and E, it appears that mostly targeted analytes are measured, leading to a cohesive certification profile. Although the IAEA database is not equally comprehensive for all groups of analytes cited above, it can still serve as an useful indicator of the status of organic constituents in RMs.

  17. Reference manual for data base on Nevada water-rights permits

    USGS Publications Warehouse

    Cartier, K.D.; Bauer, E.M.; Farnham, J.L.

    1995-01-01

    The U.S. Geological Survey and Nevada Division of Water Resources have cooperatively developed and implemented a data-base system for managing water-rights permit information for the State of Nevada. The Water-Rights Permit data base is part of an integrated system of computer data bases using the Ingres Relational Data-Base Manage-ment System, which allows efficient storage and access to water information from the State Engineer's office. The data base contains a main table, three ancillary tables, and five lookup tables, as well as a menu-driven system for entering, updating, and reporting on the data. This reference guide outlines the general functions of the system and provides a brief description of data tables and data-entry screens.

  18. 40 CFR 61.156 - Cross-reference to other asbestos regulations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Cross-reference to other asbestos... for Asbestos § 61.156 Cross-reference to other asbestos regulations. In addition to this subpart, the regulations referenced in Table 1 also apply to asbestos and may be applicable to those sources specified in...

  19. 40 CFR 61.156 - Cross-reference to other asbestos regulations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Cross-reference to other asbestos... for Asbestos § 61.156 Cross-reference to other asbestos regulations. In addition to this subpart, the regulations referenced in Table 1 also apply to asbestos and may be applicable to those sources specified in...

  20. 40 CFR 61.156 - Cross-reference to other asbestos regulations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Cross-reference to other asbestos... for Asbestos § 61.156 Cross-reference to other asbestos regulations. In addition to this subpart, the regulations referenced in Table 1 also apply to asbestos and may be applicable to those sources specified in...

  1. 40 CFR 61.156 - Cross-reference to other asbestos regulations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Cross-reference to other asbestos... for Asbestos § 61.156 Cross-reference to other asbestos regulations. In addition to this subpart, the regulations referenced in Table 1 also apply to asbestos and may be applicable to those sources specified in...

  2. 40 CFR 61.156 - Cross-reference to other asbestos regulations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Cross-reference to other asbestos... for Asbestos § 61.156 Cross-reference to other asbestos regulations. In addition to this subpart, the regulations referenced in Table 1 also apply to asbestos and may be applicable to those sources specified in...

  3. Accurate determination of reference materials and natural isolates by means of quantitative (1)h NMR spectroscopy.

    PubMed

    Frank, Oliver; Kreissl, Johanna Karoline; Daschner, Andreas; Hofmann, Thomas

    2014-03-26

    A fast and precise proton nuclear magnetic resonance (qHNMR) method for the quantitative determination of low molecular weight target molecules in reference materials and natural isolates has been validated using ERETIC 2 (Electronic REference To access In vivo Concentrations) based on the PULCON (PULse length based CONcentration determination) methodology and compared to the gravimetric results. Using an Avance III NMR spectrometer (400 MHz) equipped with a broad band observe (BBO) probe, the qHNMR method was validated by determining its linearity, range, precision, and accuracy as well as robustness and limit of quantitation. The linearity of the method was assessed by measuring samples of l-tyrosine, caffeine, or benzoic acid in a concentration range between 0.3 and 16.5 mmol/L (r(2) ≥ 0.99), whereas the interday and intraday precisions were found to be ≤2%. The recovery of a range of reference compounds was ≥98.5%, thus demonstrating the qHNMR method as a precise tool for the rapid quantitation (~15 min) of food-related target compounds in reference materials and natural isolates such as nucleotides, polyphenols, or cyclic peptides.

  4. RBS as a new primary direct reference method for measuring quantity of material

    NASA Astrophysics Data System (ADS)

    Jeynes, C.

    2017-09-01

    The quantity of material in thin films can be measured reliably, non-destructively, and at an absolute traceable accuracy with a combined standard uncertainty of 1% by Rutherford backscattering spectrometry (RBS). We have demonstrated a measurement protocol for the determination of quantity of material by RBS that has been accredited at this accuracy to the ISO 17025 standard by the United Kingdom Accreditation Service (UKAS). The method is entirely traceable to SI units relying on no artefacts, and thus qualifies as a primary direct reference method as defined by the ISO Guide 35:1985 (paragraph 9.4.1).

  5. Data tables for the 1993 National Transit Database section 15 report year

    DOT National Transportation Integrated Search

    1994-12-01

    The Data Tables For the 1993 National Transit Database Section 15 Report Year is one of three publications comprising the 1993 Annual Report. Also referred to as the National Transit Database Reporting System, it is administered by the Federal Transi...

  6. Review of footnotes and annotations to the 1949–2013 tables of standard atomic weights and tables of isotopic compositions of the elements (IUPAC Technical Report)

    DOE PAGES

    Coplen, Tyler B.; Holden, Norman E.

    2016-01-01

    Abstract The Commission on Isotopic Abundances and Atomic Weights uses annotations given in footnotes that are an integral part of the Tables of Standard Atomic Weights to alert users to the possibilities of quite extraordinary occurrences, as well as sources with abnormal atomic-weight values outside an otherwise acceptable range. The basic need for footnotes to the Standard Atomic Weights Table and equivalent annotations to the Table of Isotopic Compositions of the Elements arises from the necessity to provide users with information that is relevant to one or more elements, but that cannot be provided using numerical data in columns. Anymore » desire to increase additional information conveyed by annotations to these Tables is tempered by the need to preserve a compact format and a style that can alert users, who would not be inclined to consult either the last full element-by-element review or the full text of a current Standard Atomic Weights of the Elements report. Since 1989, the footnotes of the Tables of Standard Atomic Weights and the annotations in column 5 of the Table of Isotopic Compositions of the Elements have been harmonized by use of three lowercase footnotes, “g”, “m”, and “r”, that signify geologically exceptionally specimens (“g”), modified isotopic compositions in material subjected to undisclosed or inadvertent isotopic fractionation (“m”), and the range in isotopic composition of normal terrestrial material prevents more precise atomic-weight value being given (“r”). As some elements are assigned intervals for their standard atomic-weight values (applies to 12 elements since 2009), footnotes “g” and “r” are no longer needed for these elements.« less

  7. Review of footnotes and annotations to the 1949–2013 tables of standard atomic weights and tables of isotopic compositions of the elements (IUPAC Technical Report)

    USGS Publications Warehouse

    Coplen, Tyler B.; Holden, Norman E.

    2016-01-01

    The Commission on Isotopic Abundances and Atomic Weights uses annotations given in footnotes that are an integral part of the Tables of Standard Atomic Weights to alert users to the possibilities of quite extraordinary occurrences, as well as sources with abnormal atomic-weight values outside an otherwise acceptable range. The basic need for footnotes to the Standard Atomic Weights Table and equivalent annotations to the Table of Isotopic Compositions of the Elements arises from the necessity to provide users with information that is relevant to one or more elements, but that cannot be provided using numerical data in columns. Any desire to increase additional information conveyed by annotations to these Tables is tempered by the need to preserve a compact format and a style that can alert users, who would not be inclined to consult either the last full element-by-element review or the full text of a current Standard Atomic Weights of the Elements report. Since 1989, the footnotes of the Tables of Standard Atomic Weights and the annotations in column 5 of the Table of Isotopic Compositions of the Elements have been harmonized by use of three lowercase footnotes, “g”, “m”, and “r”, that signify geologically exceptionally specimens (“g”), modified isotopic compositions in material subjected to undisclosed or inadvertent isotopic fractionation (“m”), and the range in isotopic composition of normal terrestrial material prevents more precise atomic-weight value being given (“r”). As some elements are assigned intervals for their standard atomic-weight values (applies to 12 elements since 2009), footnotes “g” and “r” are no longer needed for these elements.

  8. Constraints on transportation of reagents, reference materials and samples, difficulties and possible solutions: a user's perspective.

    PubMed

    Blanchard, P C

    2006-01-01

    The air transportation of infectious materials is regulated by international air transport associations and based on United Nations Model regulations which have become more practical in addressing animal disease agents. However, individual countries' import and interstate requirements determine what materials can be imported and transported, and this approval process can be long, resulting in delays in organism confirmation, use of international OIE and other reference laboratories, and acquisition of reference materials, proficiency test panels, and reagents for performing necessary testing. Delays can be prevented for permits that are required for the routine work performed by a laboratory through the use of comprehensive and annually renewed permits. This process, however, does not address new and exotic agents where time is critical to an effective emergency response. This paper suggests actions by both the OIE and regulatory authorities which can assist in streamlining and expediting the permit process.

  9. New Carbonate Standard Reference Materials for Boron Isotope Geochemistry

    NASA Astrophysics Data System (ADS)

    Stewart, J.; Christopher, S. J.; Day, R. D.

    2015-12-01

    The isotopic composition of boron (δ11B) in marine carbonates is well established as a proxy for past ocean pH. Yet, before palaeoceanographic interpretation can be made, rigorous assessment of analytical uncertainty of δ11B data is required; particularly in light of recent interlaboratory comparison studies that reported significant measurement disagreement between laboratories [1]. Well characterised boron standard reference materials (SRMs) in a carbonate matrix are needed to assess the accuracy and precision of carbonate δ11B measurements throughout the entire procedural chemistry; from sample cleaning, to ionic separation of boron from the carbonate matrix, and final δ11B measurement by multi-collector inductively coupled plasma mass spectrometry. To date only two carbonate reference materials exist that have been value-assigned by the boron isotope measurement community [2]; JCp-1 (porites coral) and JCt-1 (Giant Clam) [3]. The National Institute of Standards and Technology (NIST) will supplement these existing standards with new solution based inorganic carbonate boron SRMs that replicate typical foraminiferal and coral B/Ca ratios and δ11B values. These new SRMs will not only ensure quality control of full procedural chemistry between laboratories, but have the added benefits of being both in abundant supply and free from any restrictions associated with shipment of biogenic samples derived from protected species. Here we present in-house δ11B measurements of these new boron carbonate SRM solutions. These preliminary data will feed into an interlaboratory comparison study to establish certified values for these new NIST SRMs. 1. Foster, G.L., et al., Chemical Geology, 2013. 358(0): p. 1-14. 2. Gutjahr, M., et al., Boron Isotope Intercomparison Project (BIIP): Development of a new carbonate standard for stable isotopic analyses. Geophysical Research Abstracts, EGU General Assembly 2014, 2014. 16(EGU2014-5028-1). 3. Inoue, M., et al., Geostandards and

  10. 40 CFR 60.711 - Definitions, symbols, and cross reference tables.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... audio or video recording or information storage. (14) Natural draft opening means any opening in a room... control device. (18) Utilize refers to the use of solvent that is delivered to coating mix preparation... participate in atmospheric photochemical reactions or that are measured by Method 18, 24, 25, or 25A or an...

  11. 40 CFR 60.711 - Definitions, symbols, and cross reference tables.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... audio or video recording or information storage. (14) Natural draft opening means any opening in a room... control device. (18) Utilize refers to the use of solvent that is delivered to coating mix preparation... participate in atmospheric photochemical reactions or that are measured by Method 18, 24, 25, or 25A or an...

  12. 40 CFR 60.711 - Definitions, symbols, and cross reference tables.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... audio or video recording or information storage. (14) Natural draft opening means any opening in a room... control device. (18) Utilize refers to the use of solvent that is delivered to coating mix preparation... participate in atmospheric photochemical reactions or that are measured by Method 18, 24, 25, or 25A or an...

  13. 40 CFR 60.711 - Definitions, symbols, and cross reference tables.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... audio or video recording or information storage. (14) Natural draft opening means any opening in a room... control device. (18) Utilize refers to the use of solvent that is delivered to coating mix preparation... participate in atmospheric photochemical reactions or that are measured by Method 18, 24, 25, or 25A or an...

  14. 40 CFR 60.711 - Definitions, symbols, and cross reference tables.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... audio or video recording or information storage. (14) Natural draft opening means any opening in a room... control device. (18) Utilize refers to the use of solvent that is delivered to coating mix preparation... participate in atmospheric photochemical reactions or that are measured by Method 18, 24, 25, or 25A or an...

  15. Measurements of plutonium, 237Np, and 137Cs in the BCR 482 lichen reference material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lavelle, Kevin B.; Miller, Jeffrey L.; Hanson, Susan K.

    Select anthropogenic radionuclides were measured in lichen reference material, BCR 482. This material was originally collected in Axalp, Switzerland in 1991 and is composed of the epiphytic lichen Pseudevernia furfuracea. Samples from three separate bottles of BCR 482 were analyzed for uranium, neptunium, and plutonium isotopes by inductively coupled plasma mass spectrometry (ICP-MS) and analyzed for cesium-137 by gamma-ray spectrometry. The isotopic composition of the radionuclides measured in BCR 482 suggests contributions from both global fallout resulting from historical nuclear weapons testing and more volatile materials released following the Chernobyl accident.

  16. Measurements of plutonium, 237Np, and 137Cs in the BCR 482 lichen reference material

    DOE PAGES

    Lavelle, Kevin B.; Miller, Jeffrey L.; Hanson, Susan K.; ...

    2015-10-01

    Select anthropogenic radionuclides were measured in lichen reference material, BCR 482. This material was originally collected in Axalp, Switzerland in 1991 and is composed of the epiphytic lichen Pseudevernia furfuracea. Samples from three separate bottles of BCR 482 were analyzed for uranium, neptunium, and plutonium isotopes by inductively coupled plasma mass spectrometry (ICP-MS) and analyzed for cesium-137 by gamma-ray spectrometry. The isotopic composition of the radionuclides measured in BCR 482 suggests contributions from both global fallout resulting from historical nuclear weapons testing and more volatile materials released following the Chernobyl accident.

  17. User testing and stakeholder feedback contributed to the development of understandable and useful Summary of Findings tables for Cochrane reviews.

    PubMed

    Rosenbaum, Sarah E; Glenton, Claire; Nylund, Hilde Kari; Oxman, Andrew D

    2010-06-01

    To develop a Summary of Findings (SoF) table for use in Cochrane reviews that is understandable and useful for health professionals, acceptable to Cochrane Collaboration stakeholders, and feasible to implement. We gathered stakeholder feedback on the format and content of an SoF table from an advisory group of more than 50 participants and their constituencies through e-mail consultations. We conducted user tests using a think-aloud protocol method, collecting feedback from 21 health professionals and researchers in Norway and the UK. We analyzed the feedback, defined problem areas, and generated new solutions in brainstorming workshops. Stakeholders were concerned about precision in the data representation and about production feasibility. User testing revealed unexpected comprehension problems, mainly confusion about what the different numbers referred to (class reference). Resolving the tension between achieving table precision and table simplicity became the main focus of the working group. User testing led to a table more useful and understandable for clinical audiences. We arrived at an SoF table that was acceptable to the stakeholders and in principle feasible to implement technically. Some challenges remain, including presenting continuous outcomes and technical/editorial implementation.

  18. Nicotine, acetanilide and urea multi-level 2H-, 13C- and 15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry.

    PubMed

    Schimmelmann, Arndt; Albertino, Andrea; Sauer, Peter E; Qi, Haiping; Molinie, Roland; Mesnard, François

    2009-11-01

    Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for delta13C and delta15N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: delta2H(nicotine) -162 to -45 per thousand, delta13C(nicotine) -30.05 to +7.72 per thousand, delta15N(nicotine) -6.03 to +33.62 per thousand; delta15N(acetanilide) +1.18 to +40.57 per thousand; delta13C(urea) -34.13 to +11.71 per thousand, delta15N(urea) +0.26 to +40.61 per thousand (recommended delta values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as

  19. The dosimetric impact of including the patient table in CT dose estimates

    NASA Astrophysics Data System (ADS)

    Nowik, Patrik; Bujila, Robert; Kull, Love; Andersson, Jonas; Poludniowski, Gavin

    2017-12-01

    The purpose of this study was to evaluate the dosimetric impact of including the patient table in Monte Carlo CT dose estimates for both spiral scans and scan projection radiographs (SPR). CT scan acquisitions were simulated for a Siemens SOMATOM Force scanner (Siemens Healthineers, Forchheim, Germany) with and without a patient table present. An adult male, an adult female and a pediatric female voxelized phantom were simulated. The simulated scans included tube voltages of 80 and 120 kVp. Spiral scans simulated without a patient table resulted in effective doses that were overestimated by approximately 5% compared to the same simulations performed with the patient table present. Doses in selected individual organs (breast, colon, lung, red bone marrow and stomach) were overestimated by up to 8%. Effective doses from SPR acquired with the x-ray tube stationary at 6 o’clock (posterior-anterior) were overestimated by 14-23% when the patient table was not included, with individual organ dose discrepancies (breast, colon, lung red bone marrow and stomach) all exceeding 13%. The reference entrance skin dose to the back were in this situation overestimated by 6-15%. These results highlight the importance of including the patient table in patient dose estimates for such scan situations.

  20. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. I. A review of Kjeldahl methods adopted by laboratory medicine.

    PubMed

    Chromý, Vratislav; Vinklárková, Bára; Šprongl, Luděk; Bittová, Miroslava

    2015-01-01

    We found previously that albumin-calibrated total protein in certified reference materials causes unacceptable positive bias in analysis of human sera. The simplest way to cure this defect is the use of human-based serum/plasma standards calibrated by the Kjeldahl method. Such standards, commutative with serum samples, will compensate for bias caused by lipids and bilirubin in most human sera. To find a suitable primary reference procedure for total protein in reference materials, we reviewed Kjeldahl methods adopted by laboratory medicine. We found two methods recommended for total protein in human samples: an indirect analysis based on total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. The methods found will be assessed in a subsequent article.

  1. Standard wool fabric as a reference material. [for fire toxicity tests

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Cumming, H. J.

    1977-01-01

    Standard wool fabric is investigated as a potential reference material. A screening test method for relative toxicity exposes four albino male rats enclosed in a 4.2 liter hemispherical chamber to pyrolysis effluents produced by pyrolyzing a 1.00 g sample under a variety of test conditions (200-800 C with a 40 C/min heating rate). It is found that for fabrics containing 86-100% wool, animal response remains virtually unchanged, although a 100% wool fabric is preferred as it eliminates local composition differences as a source of variation.

  2. Uncertainty evaluation in normalization of isotope delta measurement results against international reference materials.

    PubMed

    Meija, Juris; Chartrand, Michelle M G

    2018-01-01

    Isotope delta measurements are normalized against international reference standards. Although multi-point normalization is becoming a standard practice, the existing uncertainty evaluation practices are either undocumented or are incomplete. For multi-point normalization, we present errors-in-variables regression models for explicit accounting of the measurement uncertainty of the international standards along with the uncertainty that is attributed to their assigned values. This manuscript presents framework to account for the uncertainty that arises due to a small number of replicate measurements and discusses multi-laboratory data reduction while accounting for inevitable correlations between the laboratories due to the use of identical reference materials for calibration. Both frequentist and Bayesian methods of uncertainty analysis are discussed.

  3. Biscayne aquifer drinking water (USGS45): a new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Lorenz, Jennifer M.; Tarbox, Lauren V.; Buck, Bryan; Qi, Haiping; Coplen, Tyler B.

    2014-01-01

    RATIONALE As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. METHODS This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. RESULTS The δ2H and δ18O values of this reference material are –10.3 ± 0.4 ‰ and –2.238 ± 0.011 ‰, respectively, relative to VSMOW, on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. CONCLUSIONS This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. 

  4. Axial point groups: rank 1, 2, 3 and 4 property tensor tables.

    PubMed

    Litvin, Daniel B

    2015-05-01

    The form of a physical property tensor of a quasi-one-dimensional material such as a nanotube or a polymer is determined from the material's axial point group. Tables of the form of rank 1, 2, 3 and 4 property tensors are presented for a wide variety of magnetic and non-magnetic tensor types invariant under each point group in all 31 infinite series of axial point groups. An application of these tables is given in the prediction of the net polarization and magnetic-field-induced polarization in a one-dimensional longitudinal conical magnetic structure in multiferroic hexaferrites.

  5. Density-Functional-Theory-Based Equation-of-State Table of Beryllium for Inertial Confinement Fusion Applications

    NASA Astrophysics Data System (ADS)

    Ding, Y. H.; Hu, S. X.

    2017-10-01

    Beryllium has been considered a superior ablator material for inertial confinement fusion target designs. Based on density-functional-theory calculations, we have established a wide-range beryllium equation-of-state (EOS) table of density ρ = 0.001 to ρ = 500 g/cm3 and temperature T = 2000 to 108 K. Our first-principles equation-of-state (FPEOS) table is in better agreement with widely used SESAMEEOS table (SESAME2023) than the average-atom INFERNOmodel and the Purgatoriomodel. For the principal Hugoniot, our FPEOS prediction shows 10% stiffer behavior than the last two models at maximum compression. Comparisons between FPEOS and SESAMEfor off-Hugoniot conditions show that both the pressure and internal energy differences are within 20% between two EOS tables. By implementing the FPEOS table into the 1-D radiation-hydrodynamics code LILAC, we studied the EOS effects on beryllium target-shell implosions. The FPEOS simulation predicts up to an 15% higher neutron yield compared to the simulation using the SESAME2023 EOS table. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  6. Determination of polychlorinated biphenyl congeners and chlorinated pesticides in a fish tissue standard reference material.

    PubMed

    Poster, Dianne L; Kucklick, John R; Schantz, Michele M; Porter, Barbara J; Leigh, Stefan D; Wise, Stephen A

    2003-01-01

    The concentrations of a wide range of polychlorinated biphenyl congeners (PCBs) and chlorinated pesticides in a fish tissue Standard Reference Material (SRM) have been determined using multiple methods of analysis. This material, SRM 1946, Lake Superior Fish Tissue, was recently issued by the National Institute of Standards and Technology (NIST) and complements a suite of marine environmental natural-matrix SRMs that are currently available from NIST for the determination of organic contaminants such as aliphatic hydrocarbons, polycyclic aromatic hydrocarbons (PAHs), PCBs, and chlorinated pesticides. SRM 1946 is a fresh tissue homogenate (frozen) prepared from filleted adult lake trout (Salvelinus namaycush namaycush) collected from the Apostle Islands region of Lake Superior. SRM 1946 has certified and reference concentrations for PCB congeners, including the three non- ortho PCB congeners, and chlorinated pesticides. Certified concentrations are available for 30 PCB congeners and 15 chlorinated pesticides. Reference concentrations are available for 12 PCB congeners and 2 chlorinated pesticides. In addition, SRM 1946 is characterized for additional chemical constituents and properties: fatty acids, extractable fat, methylmercury, total mercury, selected trace elements, proximates, and caloric content. The characterization of chlorinated compounds is described in this paper with an emphasis on the approach used for the certification of the concentrations of PCB congeners and chlorinated pesticides. The PCB congener and chlorinated pesticide data are also compared to concentrations in other marine natural-matrix reference materials available from NIST (fish oil, mussel tissue, whale blubber, and a second fresh frozen fish tissue homogenate prepared from filleted adult lake trout collected from Lake Michigan) and from other organizations such as the National Research Council Canada (ground whole carp), the International Atomic Energy Agency (fish homogenate), and the

  7. Doorways III: Teacher Reference Materials. On School-Related Gender-Based Violence Prevention and Response

    ERIC Educational Resources Information Center

    US Agency for International Development, 2009

    2009-01-01

    The Doorways training program was designed by the U.S. Agency for International Development (USAID)-funded Safe Schools Program (Safe Schools) to enable teachers, community members and students to prevent and respond to school-related gender-based violence (SRGBV). This booklet, "Doorways III: Teacher Reference Materials on School-Related…

  8. 40 CFR Table 1 to Subpart Ccc of... - Applicability of General Provisions (40 CFR Part 63, Subpart A) to Subpart CCC

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (40 CFR Part 63, Subpart A) to Subpart CCC 1 Table 1 to Subpart CCC of Part 63 Protection of... Pt. 63, Subpt. CCC, Table 1 Table 1 to Subpart CCC of Part 63—Applicability of General Provisions (40 CFR Part 63, Subpart A) to Subpart CCC Reference Applies to Subpart CCC Explanation 63.1-63.5 Yes. 63...

  9. 40 CFR Table 1 to Subpart Ccc of... - Applicability of General Provisions (40 CFR Part 63, Subpart A) to Subpart CCC

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (40 CFR Part 63, Subpart A) to Subpart CCC 1 Table 1 to Subpart CCC of Part 63 Protection of... Pt. 63, Subpt. CCC, Table 1 Table 1 to Subpart CCC of Part 63—Applicability of General Provisions (40 CFR Part 63, Subpart A) to Subpart CCC Reference Applies to Subpart CCC Explanation 63.1-63.5 Yes. 63...

  10. 40 CFR Table 1 to Subpart Ccc of... - Applicability of General Provisions (40 CFR Part 63, Subpart A) to Subpart CCC

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (40 CFR Part 63, Subpart A) to Subpart CCC 1 Table 1 to Subpart CCC of Part 63 Protection of... Pt. 63, Subpt. CCC, Table 1 Table 1 to Subpart CCC of Part 63—Applicability of General Provisions (40 CFR Part 63, Subpart A) to Subpart CCC Reference Applies to Subpart CCC Explanation 63.1-63.5 Yes. 63...

  11. 40 CFR Table 1 to Subpart Ccc of... - Applicability of General Provisions (40 CFR Part 63, Subpart A) to Subpart CCC

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (40 CFR Part 63, Subpart A) to Subpart CCC 1 Table 1 to Subpart CCC of Part 63 Protection of... Pt. 63, Subpt. CCC, Table 1 Table 1 to Subpart CCC of Part 63—Applicability of General Provisions (40 CFR Part 63, Subpart A) to Subpart CCC Reference Applies to Subpart CCC Explanation 63.1-63.5 Yes. 63...

  12. 40 CFR Table 1 to Subpart Ccc of... - Applicability of General Provisions (40 CFR Part 63, Subpart A) to Subpart CCC

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (40 CFR Part 63, Subpart A) to Subpart CCC 1 Table 1 to Subpart CCC of Part 63 Protection of... Pt. 63, Subpt. CCC, Table 1 Table 1 to Subpart CCC of Part 63—Applicability of General Provisions (40 CFR Part 63, Subpart A) to Subpart CCC Reference Applies to Subpart CCC Explanation 63.1-63.5 Yes. 63...

  13. 40 CFR Table B-2 to Subpart B of... - Test Atmospheres

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of ASTM Standards, American Society for Testing and Materials, 1916 Race St., Philadelphia, PA..., American Society for Testing and Materials, 1916 Race St., Philadelphia, PA 19103. ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Test Atmospheres B Table B-2 to Subpart...

  14. 40 CFR Table B-2 to Subpart B of... - Test Atmospheres

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of ASTM Standards, American Society for Testing and Materials, 1916 Race St., Philadelphia, PA..., American Society for Testing and Materials, 1916 Race St., Philadelphia, PA 19103. ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Test Atmospheres B Table B-2 to Subpart...

  15. 40 CFR Table B-2 to Subpart B of... - Test Atmospheres

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of ASTM Standards, American Society for Testing and Materials, 1916 Race St., Philadelphia, PA..., American Society for Testing and Materials, 1916 Race St., Philadelphia, PA 19103. ... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Test Atmospheres B Table B-2 to Subpart...

  16. Characterization of NIST food-matrix Standard Reference Materials for their vitamin C content.

    PubMed

    Thomas, Jeanice B; Yen, James H; Sharpless, Katherine E

    2013-05-01

    The vitamin C concentrations in three food-matrix Standard Reference Materials (SRMs) from the National Institute of Standards and Technology (NIST) have been determined by liquid chromatography (LC) with absorbance detection. These materials (SRM 1549a Whole Milk Powder, SRM 1849a Infant/Adult Nutritional Formula, and SRM 3233 Fortified Breakfast Cereal) have been characterized to support analytical measurements made by food processors that are required to provide information about their products' vitamin C content on the labels of products distributed in the United States. The SRMs are primarily intended for use in validating analytical methods for the determination of selected vitamins, elements, fatty acids, and other nutrients in these materials and in similar matrixes. They can also be used for quality assurance in the characterization of test samples or in-house control materials, and for establishing measurement traceability. Within-day precision of the LC method used to measure vitamin C in the food-matrix SRMs characterized in this study ranged from 2.7% to 6.5%.

  17. Turning the table on advice programs for parents: Using placemats to enhance family interaction at restaurants

    PubMed Central

    Green, Richard B.; Hardison, William L.; Greene, Brandon F.

    1984-01-01

    There are many opportunities in a family's daily routine to enrich the interactions among its members. One such opportunity arises at family restaurants. Surveys of restaurant personnel and customers suggested the possibility of enriching family interactions by redesigning indigenous materials such as table placemats. Accordingly, we developed Table-Talk placemats that provided conversational topics and illustrated games in which the entire family could participate. After some testing of these placemats in a preschool, a field experiment was conducted with families dining in restaurants. Table-Talk placements occasioned more social and educational dialogue among family members than either traditional-placemat or no-material conditions. Social validation ratings provided by mental health counselors and the parents suggested that Table-Talk placemats occasioned healthy and enjoyable interactions among family members. PMID:16795680

  18. Preparation and certification of arsenate [As(V)] reference material, NMIJ CRM 7912-a.

    PubMed

    Narukawa, Tomohiro; Kuroiwa, Takayoshi; Narushima, Izumi; Jimbo, Yasujiro; Suzuki, Toshihiro; Chiba, Koichi

    2010-05-01

    Arsenate [As(V)] solution reference material, National Metrology Institute of Japan (NMIJ) certified reference material (CRM) 7912-a, for speciation of arsenic species was developed and certified by NMIJ, the National Institute of Advanced Industrial Science and Technology. High-purity As(2)O(3) reagent powder was dissolved in 0.8 M HNO(3) solution and As(III) was oxidized to As(V) with HNO(3) to prepare 100 mg kg(-1) of As(V) candidate CRM solution. The solution was bottled in 400 bottles (50 mL each). The concentration of As(V) was determined by four independent analytical techniques-inductively coupled plasma mass spectrometry, inductively coupled plasma optical emission spectrometry, graphite furnace atomic absorption spectrometry, and liquid chromatography inductively coupled plasma mass spectrometry-according to As(V) calibration solutions, which were prepared from the arsenic standard of the Japan Calibration Service system and whose species was guaranteed to be As(V) by NMIJ. The uncertainties of all the measurements and preparation procedures were evaluated. The certified value of As(V) in the CRM is (99.53 +/- 1.67) mg kg(-1) (k = 2).

  19. In Vitro Investigations of Human Bioaccessibility from Reference Materials Using Simulated Lung Fluids

    PubMed Central

    Pelfrêne, Aurélie; Cave, Mark R.; Wragg, Joanna; Douay, Francis

    2017-01-01

    An investigation for assessing pulmonary bioaccessibility of metals from reference materials is presented using simulated lung fluids. The objective of this paper was to contribute to an enhanced understanding of airborne particulate matter and its toxic potential following inhalation. A large set of metallic elements (Ba, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sr, and Zn) was investigated using three lung fluids (phosphate-buffered saline, Gamble’s solution and artificial lysosomal fluid) on three standard reference materials representing different types of particle sources. Composition of the leaching solution and four solid-to-liquid (S/L) ratios were tested. The results showed that bioaccessibility was speciation- (i.e., distribution) and element-dependent, with percentages varying from 0.04% for Pb to 86.0% for Cd. The higher extraction of metallic elements was obtained with the artificial lysosomal fluid, in which a relative stability of bioaccessibility was observed in a large range of S/L ratios from 1/1000 to 1/10,000. For further investigations, it is suggested that this method be used to assess lung bioaccessibility of metals from smelter-impacted dusts. PMID:28125027

  20. Development of a standard reference material for Cr(vi) in contaminated soil

    USGS Publications Warehouse

    Nagourney, S.J.; Wilson, S.A.; Buckley, B.; Kingston, H.M.S.; Yang, S.-Y.; Long, S.E.

    2008-01-01

    Over the last several decades, considerable contamination by hexavalent chromium has resulted from the land disposal of Chromite Ore Processing Residue (COPR). COPR contains a number of hexavalent chromium-bearing compounds that were produced in high temperature industrial processes. Concern over the carcinogenic potential of this chromium species, and its environmental mobility, has resulted in efforts to remediate these waste sites. To provide support to analytical measurements of hexavalent chromium, a candidate National Institute of Standards and Technology (NIST) Standard Reference Material?? (SRM 2701), having a hexavalent chromium content of approximately 500 mg kg -1, has been developed using material collected from a waste site in Hudson County, New Jersey, USA. The collection, processing, preparation and preliminary physico-chemical characterization of the material are discussed. A two-phase multi-laboratory testing study was carried out to provide data on material homogeneity and to assess the stability of the material over the duration of the study. The study was designed to incorporate several United States Environmental Protection Agency (USEPA) determinative methods for hexavalent chromium, including Method 6800 which is based on speciated isotope dilution mass spectrometry (SIDMS), an approach which can account for chromium species inter-conversion during the extraction and measurement sequence. This journal is ?? The Royal Society of Chemistry 2008.

  1. Symbol Tables and Branch Tables: Linking Applications Together

    NASA Technical Reports Server (NTRS)

    Handler, Louis M.

    2011-01-01

    This document explores the computer techniques used to execute software whose parts are compiled and linked separately. The computer techniques include using a branch table or indirect address table to connect the parts. Methods of storing the information in data structures are discussed as well as differences between C and C++.

  2. 76 FR 2883 - Folding Metal Tables and Chairs From the People's Republic of China: Final Results of 2007-2008...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-18

    ...; and, Banquet tables. A banquet table is a rectangular table with a plastic or laminated wood table top...; and those that have seats or backs made of plastic or other materials. The subject merchandise is... and a seat and back of plastic, with measurements of: height: 32.5 inches; width: 18.5 inches; and...

  3. Critical assessment of the performance of electronic moisture analyzers for small amounts of environmental samples and biological reference materials.

    PubMed

    Krachler, M

    2001-12-01

    Two electronic moisture analyzers were critically evaluated with regard to their suitability for determining moisture in small amounts (< or = 200 mg) of various environmental matrices such as leaves, needles, soil, peat, sediments, and sewage sludge, as well as various biological reference materials. To this end, several homogeneous bulk materials were prepared which were subsequently employed for the development and optimization of all analytical procedures. The key features of the moisture analyzers included a halogen or ceramic heater and an integrated balance with a resolution of 0.1 mg, which is an essential prerequisite for obtaining precise results. Oven drying of the bulk materials in a conventional oven at 105 degrees C until constant mass served as reference method. A heating temperature of 65degrees C was found to provide accurate and precise results for almost all matrices investigated. To further improve the accuracy and precision, other critical parameters such as handling of sample pans, standby temperature, and measurement delay were optimized. Because of its ponderous heating behavior, the performance of the ceramic radiator was inferior to that of the halogen heater, which produced moisture results comparable to those obtained by oven drying. The developed drying procedures were successfully applied to the fast moisture analysis (1.4-6.3 min) of certified biological reference materials of similar provenance to the investigated the bulk materials. Moisture results for 200 mg aliquots ranged from 1.4 to 7.8% and good agreement was obtained between the recommended drying procedure for the reference materials and the electronic moisture analyzers with absolute uncertainties amounting to 0.1% and 0.2-0.3%, respectively.

  4. Tables for technical writers

    Treesearch

    E. vH. Larson

    1947-01-01

    Practically every publication we issue contains tables of some sort. Tables offer a convenient way of presenting many kinds of information. And tables are badly abused. There are few places a writer can go to find out how to construct clear, compact, easy-to-read tables, and how to use them.

  5. Biscayne aquifer drinking water (USGS45): a new isotopic reference material for δ2H and δ18O measurements of water.

    PubMed

    Lorenz, Jennifer M; Tarbox, Lauren; Buck, Bryan; Qi, Haiping; Coplen, Tyler B

    2014-10-15

    As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. The δ(2)H and δ(18)O values of this reference material are -10.3 ± 0.4‰ and -2.238 ± 0.011‰, respectively, relative to VSMOW, on scales normalized such that the δ(2)H and δ(18)O values of SLAP reference water are, respectively, -428 and -55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc ) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.

  6. TableSeer: Automatic Table Extraction, Search, and Understanding

    ERIC Educational Resources Information Center

    Liu, Ying

    2009-01-01

    Tables are ubiquitous with a history that pre-dates that of sentential text. Authors often report a summary of their most important findings using tabular structure in documents. For example, scientists widely use tables to present the latest experimental results or statistical data in a condensed fashion. Along with the explosive development of…

  7. Determination of tungsten in geochemical reference material basalt Columbia River 2 by radiochemical neutron activation analysis and inductively coupled plasma mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morrison, Samuel S.; Beck, Chelsie L.; Bowen, James M.

    Environmental tungsten (W) analyses are inhibited by a lack of reference materials and practical methods to remove isobaric and radiometric interferences. We present a method that evaluates the potential use of commercially available sediment, Basalt Columbia River-2 (BCR-2), as a reference material using neutron activation analysis (NAA) and mass spectrometry. Tungsten concentrations using both methods are in statistical agreement at the 95% confidence interval (92 ± 4 ng/g for NAA and 100 ±7 ng/g for mass spectrometry) with recoveries greater than 95%. These results indicate that BCR-2 may be suitable as a reference material for future studies.

  8. Challenges in the size analysis of a silica nanoparticle mixture as candidate certified reference material

    NASA Astrophysics Data System (ADS)

    Kestens, Vikram; Roebben, Gert; Herrmann, Jan; Jämting, Åsa; Coleman, Victoria; Minelli, Caterina; Clifford, Charles; De Temmerman, Pieter-Jan; Mast, Jan; Junjie, Liu; Babick, Frank; Cölfen, Helmut; Emons, Hendrik

    2016-06-01

    A new certified reference material for quality control of nanoparticle size analysis methods has been developed and produced by the Institute for Reference Materials and Measurements of the European Commission's Joint Research Centre. The material, ERM-FD102, consists of an aqueous suspension of a mixture of silica nanoparticle populations of distinct particle size and origin. The characterisation relied on an interlaboratory comparison study in which 30 laboratories of demonstrated competence participated with a variety of techniques for particle size analysis. After scrutinising the received datasets, certified and indicative values for different method-defined equivalent diameters that are specific for dynamic light scattering (DLS), centrifugal liquid sedimentation (CLS), scanning and transmission electron microscopy (SEM and TEM), atomic force microscopy (AFM), particle tracking analysis (PTA) and asymmetrical-flow field-flow fractionation (AF4) were assigned. The value assignment was a particular challenge because metrological concepts were not always interpreted uniformly across all participating laboratories. This paper presents the main elements and results of the ERM-FD102 characterisation study and discusses in particular the key issues of measurand definition and the estimation of measurement uncertainty.

  9. Comprehensive inter-laboratory calibration of reference materials for δ18O versus VSMOW using various on-line high-temperature conversion techniques

    USGS Publications Warehouse

    Brand, Willi A.; Coplen, Tyler B.; Aerts-Bijma, Anita T.; Bohlke, John Karl; Gehre, Matthias; Geilmann, Heike; Groning, Manfred; Jansen, Henk G.; Meijer, Harro A. J.; Mroczkowski, Stanley J.; Qi, Haiping; Soergel, Karin; Stuart-Williams, Hilary; Weise, Stephan M.; Werner, Roland A.

    2009-01-01

    Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC) in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125‰, an artificially enriched reference water (δ18O of +78.91‰) and two barium sulfates (one depleted and one enriched in 18O) were prepared and calibrated relative to VSMOW2 and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded:Reference materialδ18O and estimated combined uncertainty IAEA-602 benzoic acid+71.28 ± 0.36‰USGS35 sodium nitrate+56.81 ± 0.31‰IAEA-NO-3 potassium nitrate+25.32 ± 0.29‰IAEA-601 benzoic acid+23.14 ± 0.19‰IAEA-SO-5 barium sulfate+12.13 ± 0.33‰NBS 127 barium sulfate+8.59 ± 0.26‰VSMOW2 water0‰IAEA-600 caffeine−3.48 ± 0.53‰IAEA-SO-6 barium sulfate−11.35 ± 0.31‰USGS34 potassium nitrate−27.78 ± 0.37‰SLAP water−55.5‰The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for δ18O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (δ18O) of nitrates, sulfates, or organic material should explicitly state in their reports the δ18O values of two or more internationally distributed nitrates (USGS34, IAEA-NO-3, and USGS35), sulfates (IAEA-SO-5, IAEA

  10. Applications of New Synthetic Uranium Reference Materials for Geochemistry Research (Invited)

    NASA Astrophysics Data System (ADS)

    Richter, S.; Weyer, S.; Alonso, A.; Aregbe, Y.; Kuehn, H.; Eykens, R.; Verbruggen, A.; Wellum, R.

    2009-12-01

    For many applications in geochemistry research isotope ratio measurements play a significant role. In geochronology isotope abundances of uranium and its daughter products thorium and lead are being used to determine the age and history of various samples of geological interest. For measuring the isotopic compositions of these elements by mass spectrometry, suitable isotope reference materials are needed to validate measurement procedures and to calibrate multi-collector and ion counting detector systems. IRMM is a recognized provider for nuclear isotope reference materials to the nuclear industry and nuclear safeguards authorities, which are also being applied widely for geochemical applications. The preparation of several new synthetic uranium reference materials at IRMM during the recent five years has provided significant impacts on geochemical research. As an example, the IRMM-074 series of gravimetrically prepared uranium mixtures for linearity testing of secondary electron multipliers (SEMs) has been applied for the redetermination of the secular equilibrium 234U/238U value and the 234U half-life by Cheng et al (2009). Due to the use of IRMM-074, results with smaller uncertainties were obtained, which are shifted by about 0.04% compared to the commonly used values published earlier by Cheng et al. in 2000. This has a significant impact for U isotope measurements in geochemistry.. As a further example, the new double spike IRMM-3636 with a 233U/236U ratio of 1:1 and an expanded uncertainty as low as 0.016% (coverage factor k=2, 95% confidence level) was prepared gravimetrically. This double spike allows internal mass fractionation correction for high precision 235U/238U ratio measurements of close to natural samples. Using the new double spike IRMM-3636, the 235U/238U ratios for several commonly used natural U standard materials from NIST/NBL and IRMM, such as e.g. NBS960 (=NBL CRM-112a), NBS950a,b and IRMM-184, have been re-measured with improved precision

  11. Quality Control of Next-generation Sequencing-based In vitro Diagnostic Test for Onco-relevant Mutations Using Multiplex Reference Materials in Plasma.

    PubMed

    Liu, Donglai; Zhou, Haiwei; Shi, Dawei; Shen, Shu; Tian, Yabin; Wang, Lin; Lou, Jiatao; Cong, Rong; Lu, Juan; Zhang, Henghui; Zhao, Meiru; Zhu, Shida; Cao, Zhisheng; Jin, Ruilin; Wang, Yin; Zhang, Xiaoni; Yang, Guohua; Wang, Youchun; Zhang, Chuntao

    2018-01-01

    Background: Widespread clinical implementation of next-generation sequencing (NGS)-based cancer in vitro diagnostic tests (IVDs) highlighted the urgency to establish reference materials which could provide full control of the process from nucleic acid extraction to test report generation. The formalin-fixed, paraffin-embedded (FFPE) tissue and blood plasma containing circulating tumor deoxyribonucleic acid (ctDNA) were mostly used for clinically detecting onco-relevant mutations. Methods: We respectively developed multiplex FFPE and plasma reference materials covering three clinically onco-relevant mutations within the epidermal growth factor receptor ( EGFR ) gene at serial allelic frequencies. All reference materials were quantified and validated via droplet digital polymerase chain reaction (ddPCR), and then were distributed to eight domestic manufacturers for the collaborative evaluation of the performance of several domestic NGS-based cancer IVDs covering four major NGS platforms (NextSeq, HiSeq, Ion Proton and BGISEQ). Results: All expected mutations except one at extremely low allelic frequencies were detected, despite some differences in coefficient of variation (CV) which increased with the decrease of allelic frequency (CVs ranging from 18% to 106%). It was worth noting that the CV value seemed to correlate with a particular mutation as well. The repeatability of determination of different mutations was L858R>T790M>19del. Conclusions: The results indicated our reference materials would be pivotal for quality control of NGS-based cancer IVDs and would guide the further development of reference materials covering more onco-relevant mutations.

  12. TogoTable: cross-database annotation system using the Resource Description Framework (RDF) data model.

    PubMed

    Kawano, Shin; Watanabe, Tsutomu; Mizuguchi, Sohei; Araki, Norie; Katayama, Toshiaki; Yamaguchi, Atsuko

    2014-07-01

    TogoTable (http://togotable.dbcls.jp/) is a web tool that adds user-specified annotations to a table that a user uploads. Annotations are drawn from several biological databases that use the Resource Description Framework (RDF) data model. TogoTable uses database identifiers (IDs) in the table as a query key for searching. RDF data, which form a network called Linked Open Data (LOD), can be searched from SPARQL endpoints using a SPARQL query language. Because TogoTable uses RDF, it can integrate annotations from not only the reference database to which the IDs originally belong, but also externally linked databases via the LOD network. For example, annotations in the Protein Data Bank can be retrieved using GeneID through links provided by the UniProt RDF. Because RDF has been standardized by the World Wide Web Consortium, any database with annotations based on the RDF data model can be easily incorporated into this tool. We believe that TogoTable is a valuable Web tool, particularly for experimental biologists who need to process huge amounts of data such as high-throughput experimental output. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  13. Production and certification of NIST Standard Reference Material 2372 Human DNA Quantitation Standard.

    PubMed

    Kline, Margaret C; Duewer, David L; Travis, John C; Smith, Melody V; Redman, Janette W; Vallone, Peter M; Decker, Amy E; Butler, John M

    2009-06-01

    Modern highly multiplexed short tandem repeat (STR) assays used by the forensic human-identity community require tight control of the initial amount of sample DNA amplified in the polymerase chain reaction (PCR) process. This, in turn, requires the ability to reproducibly measure the concentration of human DNA, [DNA], in a sample extract. Quantitative PCR (qPCR) techniques can determine the number of intact stretches of DNA of specified nucleotide sequence in an extremely small sample; however, these assays must be calibrated with DNA extracts of well-characterized and stable composition. By 2004, studies coordinated by or reported to the National Institute of Standards and Technology (NIST) indicated that a well-characterized, stable human DNA quantitation certified reference material (CRM) could help the forensic community reduce within- and among-laboratory quantitation variability. To ensure that the stability of such a quantitation standard can be monitored and that, if and when required, equivalent replacement materials can be prepared, a measurement of some stable quantity directly related to [DNA] is required. Using a long-established conventional relationship linking optical density (properly designated as decadic attenuance) at 260 nm with [DNA] in aqueous solution, NIST Standard Reference Material (SRM) 2372 Human DNA Quantitation Standard was issued in October 2007. This SRM consists of three quite different DNA extracts: a single-source male, a multiple-source female, and a mixture of male and female sources. All three SRM components have very similar optical densities, and thus very similar conventional [DNA]. The materials perform very similarly in several widely used gender-neutral assays, demonstrating that the combination of appropriate preparation methods and metrologically sound spectrophotometric measurements enables the preparation and certification of quantitation [DNA] standards that are both maintainable and of practical utility.

  14. Hot cell examination table

    DOEpatents

    Gaal, Peter S.; Ebejer, Lino P.; Kareis, James H.; Schlegel, Gary L.

    1991-01-01

    A table for use in a hot cell or similar controlled environment for use in examining specimens. The table has a movable table top that can be moved relative to a table frame. A shaft is fixedly mounted to the frame for axial rotation. A shaft traveler having a plurality of tilted rollers biased against the shaft is connected to the table top such that rotation of the shaft causes the shaft traveler to roll along the shaft. An electromagnetic drive is connected to the shaft and the frame for controllably rotating the shaft.

  15. Determination of polychlorinated dibenzo-p-dioxin and dibenzofuran congeners in air particulate and marine sediment standard reference materials (SRMs).

    PubMed

    Chiu, C H; Turle, R; Poole, G; Thibert, B; Brubaker, W W; Schantz, M M; Wise, S A

    2001-02-01

    Due to the limited number of environmental matrix certified reference materials (CRMs) with assigned values for natural levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), an interlaboratory study was undertaken by the National Institute of Standards and Technology (NIST) and Environment Canada to establish reference concentration values for selected PCDD/Fs in two well-characterized NIST Standard Reference Materials (SRMs): SRM 1649a (Urban Dust) and SRM 1944 (New York/New Jersey Waterway Sediment). Results from 14 laboratories were used to provide reference values for the seventeen 2, 3, 7, 8-substituted PCDD/F congeners, the totals for individual tetra- through hepta-substituted PCDD/F homologues, and the total amount of tetra- through hepta-substituted PCDD/Fs. The mass fractions for the individual 2, 3, 7, 8-substituted congeners range from approximately 0.01 microg/kg to 7 microg/kg dry mass.

  16. [Preparation and certification of mussel reference material for organochlorine pesticides and polychlorinated biphenyls using isotope dilution-high resolution mass spectrometry].

    PubMed

    Lu, Xianbo; Chen, Jiping; Wang, Shuqiu; Zou, Lili; Tian, Yuzeng; Ni, Yuwen; Su, Fan

    2012-09-01

    A method for the preparation and certification of the reference material of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in mussel tissue is described. The mussel tissue from Dalian Bay was frozen-dried, comminuted, sieved, homogenized, packaged, and sterilized by 60Co radiation sterilization in turn. The certified values for 18 OCPs and 16 PCBs were determined by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) using isotope dilution and internal standard quantitation techniques. The certified values were validated and given based on seven accredited laboratories, and these values are traceable to the SI (international system of units) through gravimetrically prepared standards of established purity and measurement intercomparisons. The certified values of PCBs and OCPs in mussel span 4 orders of magnitude with a relative uncertainty of about 10%. This material is a natural biological material with confirmed good homogeneity and stability, and it was approved as the grade "primary reference material" (GBW10069) in June 2012 in China. This reference material provided necessary quality control products for our country to implement the Stockholm Treaty on the monitoring of persistent organic pollutants (POPs). The material is intended to be used for the method validation and quality control in the determination of OCPs and PCBs in biota samples.

  17. Nanoscale reference materials for environmental, health and safety measurements: needs, gaps and opportunities.

    PubMed

    Stefaniak, Aleksandr B; Hackley, Vincent A; Roebben, Gert; Ehara, Kensei; Hankin, Steve; Postek, Michael T; Lynch, Iseult; Fu, Wei-En; Linsinger, Thomas P J; Thünemann, Andreas F

    2013-12-01

    The authors critically reviewed published lists of nano-objects and their physico-chemical properties deemed important for risk assessment and discussed metrological challenges associated with the development of nanoscale reference materials (RMs). Five lists were identified that contained 25 (classes of) nano-objects; only four (gold, silicon dioxide, silver, titanium dioxide) appeared on all lists. Twenty-three properties were identified for characterisation; only (specific) surface area appeared on all lists. The key themes that emerged from this review were: 1) various groups have prioritised nano-objects for development as "candidate RMs" with limited consensus; 2) a lack of harmonised terminology hinders accurate description of many nano-object properties; 3) many properties identified for characterisation are ill-defined or qualitative and hence are not metrologically traceable; 4) standardised protocols are critically needed for characterisation of nano-objects as delivered in relevant media and as administered to toxicological models; 5) the measurement processes being used to characterise a nano-object must be understood because instruments may measure a given sample in a different way; 6) appropriate RMs should be used for both accurate instrument calibration and for more general testing purposes (e.g., protocol validation); 7) there is a need to clarify that where RMs are not available, if "(representative) test materials" that lack reference or certified values may be useful for toxicology testing and 8) there is a need for consensus building within the nanotechnology and environmental, health and safety communities to prioritise RM needs and better define the required properties and (physical or chemical) forms of the candidate materials.

  18. Slavic Americans: A Comparative and Critical Analysis of Leading Reference Sources.

    ERIC Educational Resources Information Center

    Wertsman, Vladimir F.

    2002-01-01

    Examines how Slavic American groups are treated in a variety of reference sources and what should be done in the future to provide more complete and accurate information to interested researchers. A table compares the 10 reference sources (excluding the U.S. Census) with respect to the information they provide on the 20 Slavic American groups. (SM)

  19. Types of architectural structures and the use of smart materials

    NASA Astrophysics Data System (ADS)

    Tavşan, Cengiz; Sipahi, Serkan

    2017-07-01

    about smart materials; the second discusses the types and characteristics of smart materials over the tables detailing their utilization and functions in the structures included in the set of examples. The final section of the study, on the other hand, elaborates on the findings, discussing them with reference to the types of structures.

  20. NIST Standard Reference Material 3600: Absolute Intensity Calibration Standard for Small-Angle X-ray Scattering

    DOE PAGES

    Allen, Andrew J.; Zhang, Fan; Kline, R. Joseph; ...

    2017-03-07

    The certification of a new standard reference material for small-angle scattering [NIST Standard Reference Material (SRM) 3600: Absolute Intensity Calibration Standard for Small-Angle X-ray Scattering (SAXS)], based on glassy carbon, is presented. Creation of this SRM relies on the intrinsic primary calibration capabilities of the ultra-small-angle X-ray scattering technique. This article describes how the intensity calibration has been achieved and validated in the certified Q range, Q = 0.008–0.25 Å –1, together with the purpose, use and availability of the SRM. The intensity calibration afforded by this robust and stable SRM should be applicable universally to all SAXS instruments thatmore » employ a transmission measurement geometry, working with a wide range of X-ray energies or wavelengths. As a result, the validation of the SRM SAXS intensity calibration using small-angle neutron scattering (SANS) is discussed, together with the prospects for including SANS in a future renewal certification.« less

  1. NIST Standard Reference Material 3600: Absolute Intensity Calibration Standard for Small-Angle X-ray Scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, Andrew J.; Zhang, Fan; Kline, R. Joseph

    The certification of a new standard reference material for small-angle scattering [NIST Standard Reference Material (SRM) 3600: Absolute Intensity Calibration Standard for Small-Angle X-ray Scattering (SAXS)], based on glassy carbon, is presented. Creation of this SRM relies on the intrinsic primary calibration capabilities of the ultra-small-angle X-ray scattering technique. This article describes how the intensity calibration has been achieved and validated in the certified Q range, Q = 0.008–0.25 Å –1, together with the purpose, use and availability of the SRM. The intensity calibration afforded by this robust and stable SRM should be applicable universally to all SAXS instruments thatmore » employ a transmission measurement geometry, working with a wide range of X-ray energies or wavelengths. As a result, the validation of the SRM SAXS intensity calibration using small-angle neutron scattering (SANS) is discussed, together with the prospects for including SANS in a future renewal certification.« less

  2. NIST Standard Reference Material 3600: Absolute Intensity Calibration Standard for Small-Angle X-ray Scattering.

    PubMed

    Allen, Andrew J; Zhang, Fan; Kline, R Joseph; Guthrie, William F; Ilavsky, Jan

    2017-04-01

    The certification of a new standard reference material for small-angle scattering [NIST Standard Reference Material (SRM) 3600: Absolute Intensity Calibration Standard for Small-Angle X-ray Scattering (SAXS)], based on glassy carbon, is presented. Creation of this SRM relies on the intrinsic primary calibration capabilities of the ultra-small-angle X-ray scattering technique. This article describes how the intensity calibration has been achieved and validated in the certified Q range, Q = 0.008-0.25 Å -1 , together with the purpose, use and availability of the SRM. The intensity calibration afforded by this robust and stable SRM should be applicable universally to all SAXS instruments that employ a transmission measurement geometry, working with a wide range of X-ray energies or wavelengths. The validation of the SRM SAXS intensity calibration using small-angle neutron scattering (SANS) is discussed, together with the prospects for including SANS in a future renewal certification.

  3. Helium tables.

    NASA Technical Reports Server (NTRS)

    Havill, Clinton H

    1928-01-01

    These tables are intended to provide a standard method and to facilitate the calculation of the quantity of "Standard Helium" in high pressure containers. The research data and the formulas used in the preparation of the tables were furnished by the Research Laboratory of Physical Chemistry, of the Massachusetts Institute of Technology.

  4. Some References on Metric Information.

    ERIC Educational Resources Information Center

    National Bureau of Standards (DOC), Washington, DC.

    This resource work lists metric information published by the U.S. Government and the American National Standards Institute. Also organizations marketing metric materials for education are given. A short table of conversions is included as is a listing of basic metric facts for everyday living. (LS)

  5. 40 CFR Table C-5 to Subpart C of... - Summary of Comparability Field Testing Campaign Site and Seasonal Requirements for Class II and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Campaign Site and Seasonal Requirements for Class II and III FEMs for PM10â2.5 and PM2.5 C Table C-5 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Between Candidate Methods and Reference Methods Pt. 53, Subpt. C, Table C-5 Table C-5 to Subpart C of Part...

  6. 40 CFR Table C-5 to Subpart C of... - Summary of Comparability Field Testing Campaign Site and Seasonal Requirements for Class II and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Campaign Site and Seasonal Requirements for Class II and III FEMs for PM 10-2,5 and PM 2.5 C Table C-5 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Between Candidate Methods and Reference Methods Pt. 53, Subpt. C, Table C-5 Table C-5 to Subpart C of Part...

  7. 40 CFR Table C-5 to Subpart C of... - Summary of Comparability Field Testing Campaign Site and Seasonal Requirements for Class II and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Campaign Site and Seasonal Requirements for Class II and III FEMs for PM 10-2.5 and PM 2.5 C Table C-5 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Between Candidate Methods and Reference Methods Pt. 53, Subpt. C, Table C-5 Table C-5 to Subpart C of Part...

  8. 40 CFR Table C-5 to Subpart C of... - Summary of Comparability Field Testing Campaign Site and Seasonal Requirements for Class II and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Campaign Site and Seasonal Requirements for Class II and III FEMs for PM10â2.5 and PM2.5 C Table C-5 to Subpart C of Part 53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Between Candidate Methods and Reference Methods Pt. 53, Subpt. C, Table C-5 Table C-5 to Subpart C of Part...

  9. Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

    PubMed Central

    Tarmizi, Azmil Haizam Ahmad; Lin, Siew Wai; Kuntom, Ainie

    2008-01-01

    This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of −20 °C, 0 °C, 6 °C and 24 °C upon storage for one year. PMID:19609396

  10. Comprehensive Pb-Sr-Nd-Hf isotopic, trace element, and mineralogical characterization of mafic to ultramafic rock reference materials

    NASA Astrophysics Data System (ADS)

    Fourny, Anaïs.; Weis, Dominique; Scoates, James S.

    2016-03-01

    Controlling the accuracy and precision of geochemical analyses requires the use of characterized reference materials with matrices similar to those of the unknown samples being analyzed. We report a comprehensive Pb-Sr-Nd-Hf isotopic and trace element concentration data set, combined with quantitative phase analysis by XRD Rietveld refinement, for a wide range of mafic to ultramafic rock reference materials analyzed at the Pacific Centre for Isotopic and Geochemical Research, University of British Columbia. The samples include a pyroxenite (NIM-P), five basalts (BHVO-2, BIR-1a, JB-3, BE-N, GSR-3), a diabase (W-2), a dolerite (DNC-1), a norite (NIM-N), and an anorthosite (AN-G); results from a leucogabbro (Stillwater) are also reported. Individual isotopic ratios determined by MC-ICP-MS and TIMS, and multielement analyses by HR-ICP-MS are reported with 4-12 complete analytical duplicates for each sample. The basaltic reference materials have coherent Sr and Nd isotopic ratios with external precision below 50 ppm (2SD) and below 100 ppm for Hf isotopes (except BIR-1a). For Pb isotopic reproducibility, several of the basalts (JB-3, BHVO-2) require acid leaching prior to dissolution. The plutonic reference materials also have coherent Sr and Nd isotopic ratios (<50 ppm), however, obtaining good reproducibility for Pb and Hf isotopic ratios is more challenging for NIM-P, NIM-N, and AN-G due to a variety of factors, including postcrystallization Pb mobility and the presence of accessory zircon. Collectively, these results form a comprehensive new database that can be used by the geochemical community for evaluating the radiogenic isotope and trace element compositions of volcanic and plutonic mafic-ultramafic rocks.

  11. Doorways II: Community Counselor Reference Materials. On School-Related Gender-Based Violence Prevention and Response

    ERIC Educational Resources Information Center

    US Agency for International Development, 2009

    2009-01-01

    The Doorways training program was designed by the U.S. Agency for International Development (USAID)-funded Safe Schools Program (Safe Schools) to enable teachers, community members and students to prevent and respond to school-related gender-based violence (SRGBV). This booklet, "Doorways II: Community Counselor Reference Materials on…

  12. Development and certification of a coal fly ash certified reference material for selected polycyclic aromatic hydrocarbons.

    PubMed

    Cao, X; Xu, X; Cui, W; Xi, Z

    2001-08-01

    The development and certification of a coal fly ash certified reference material (CRM) for polycyclic aromatic hydrocarbons (PAH) is described; this is the first natural matrix CRM for organic environmental analysis in China. The homogeneity and stability of this material have been tested by HPLC. The concentrations of several PAH were determined by use of two independent, different methods--solvent extraction-HPLC analysis with UV detection coupled with fluorescence detection (FLD) and solvent extraction, isolation with a silica column, and GC analysis with flame ionization detection (FID). Five certified values were determined: phenanthrene 7.1 +/- 2.6 microg g(-1), anthracene 2.0 +/- 0.8 microg g(-1), fluoranthene 7.4 +/- 1.9 microg g(-1), pyrene 7 +/- 2 microg g(-1), and benzo[a]pyrene 1.3 +/- 0.3 microg g(-1). Reference values for several other PAH are also suggested.

  13. International Standards and Reference Materials for Quantitative Molecular Infectious Disease Testing

    PubMed Central

    Madej, Roberta M.; Davis, Jack; Holden, Marcia J.; Kwang, Stan; Labourier, Emmanuel; Schneider, George J.

    2010-01-01

    The utility of quantitative molecular diagnostics for patient management depends on the ability to relate patient results to prior results or to absolute values in clinical practice guidelines. To do this, those results need to be comparable across time and methods, either by producing the same value across methods and test versions or by using reliable and stable conversions. Universally available standards and reference materials specific to quantitative molecular technologies are critical to this process but are few in number. This review describes recent history in the establishment of international standards for nucleic acid test development, organizations involved in current efforts, and future issues and initiatives. PMID:20075208

  14. Reference materials for the monitoring of the aquatic environment--a review with special emphasis on organic priority pollutants.

    PubMed

    Bercaru, Ofelia; Gawlik, Bernd Manfred; Ulberth, Franz; Vandecasteele, Carlo

    2003-08-01

    During recent years, the awareness of quality assurance and quality control in environmental analyses has constantly increased, especially due to the implementation of new guidelines and regulations at both the national and international level. Achieving comparable results by using certified reference materials is one of the primary concerns of the scientific community. As a result, there is a growing demand for certified reference materials to cover different matrices and pollutants. Moreover, these CRMs should be in close relationship to the determinants and target concentrations required by environmental bodies and European Directives as well. Supplementary information to this paper presents an inventory of reference materials available on the market from different suppliers against the priority pollutants listed in the Water Framework Directive. These CRMs cover matrices such as water, sediment and biota. The use of CRMs in relationship to appropriate analytical methods and relevant determinants is discussed and the need for matrix-CRMs, particularly for organic pollutants is emphasised. The use of proficiency testing schemes as an alternative for the lack of appropriate CRMs and future trends in the production of CRMs within the BCR framework are also discussed.

  15. Laboratory Reference Spectroscopy of Icy Satellite Candidate Surface Materials (Invited)

    NASA Astrophysics Data System (ADS)

    Dalton, J. B.; Jamieson, C. S.; Shirley, J. H.; Pitman, K. M.; Kariya, M.; Crandall, P.

    2013-12-01

    The bulk of our knowledge of icy satellite composition continues to be derived from ultraviolet, visible and infrared remote sensing observations. Interpretation of remote sensing observations relies on availability of laboratory reference spectra of candidate surface materials. These are compared directly to observations, or incorporated into models to generate synthetic spectra representing mixtures of the candidate materials. Spectral measurements for the study of icy satellites must be taken under appropriate conditions (cf. Dalton, 2010; also http://mos.seti.org/icyworldspectra.html for a database of compounds) of temperature (typically 50 to 150 K), pressure (from 10-9 to 10-3 Torr), viewing geometry, (i.e., reflectance), and optical depth (must manifest near infrared bands but avoid saturation in the mid-infrared fundamentals). The Planetary Ice Characterization Laboratory (PICL) is being developed at JPL to provide robust reference spectra for icy satellite surface materials. These include sulfate hydrates, hydrated and hydroxylated minerals, and both organic and inorganic volatile ices. Spectral measurements are performed using an Analytical Spectral Devices FR3 portable grating spectrometer from .35 to 2.5 microns, and a Thermo-Nicolet 6500 Fourier-Transform InfraRed (FTIR) spectrometer from 1.25 to 20 microns. These are interfaced with the Basic Extraterrestrial Environment Simulation Testbed (BEEST), a vacuum chamber capable of pressures below 10-9 Torr with a closed loop liquid helium cryostat with custom heating element capable of temperatures from 30-800 Kelvins. To generate optical constants (real and imaginary index of refraction) for use in nonlinear mixing models (i.e., Hapke, 1981 and Shkuratov, 1999), samples are ground and sieved to six different size fractions or deposited at varying rates to provide a range of grain sizes for optical constants calculations based on subtractive Kramers-Kronig combined with Hapke forward modeling (Dalton and

  16. A soil sampling reference site: the challenge in defining reference material for sampling.

    PubMed

    de Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Fajgelj, Ales; Jacimovic, Radojko; Jeran, Zvonka; Sansone, Umberto; van der Perk, Marcel

    2008-11-01

    In the frame of the international SOILSAMP project, funded and coordinated by the Italian Environmental Protection Agency, an agricultural area was established as a reference site suitable for performing soil sampling inter-comparison exercises. The reference site was characterized for trace element content in soil, in terms of the spatial and temporal variability of their mass fraction. Considering that the behaviour of long-lived radionuclides in soil can be expected to be similar to that of some stable trace elements and that the distribution of these trace elements in soil can simulate the distribution of radionuclides, the reference site characterised in term of trace elements, can be also used to compare the soil sampling strategies developed for radionuclide investigations.

  17. Database of Geoscientific References Through 2007 for Afghanistan, Version 2

    USGS Publications Warehouse

    Eppinger, Robert G.; Sipeki, Julianna; Scofield, M.L. Sco

    2007-01-01

    This report describes an accompanying database of geoscientific references for the country of Afghanistan. Included is an accompanying Microsoft? Access 2003 database of geoscientific references for the country of Afghanistan. The reference compilation is part of a larger joint study of Afghanistan's energy, mineral, and water resources, and geologic hazards, currently underway by the U.S. Geological Survey, the British Geological Survey, and the Afghanistan Geological Survey. The database includes both published (n = 2,462) and unpublished (n = 174) references compiled through September, 2007. The references comprise two separate tables in the Access database. The reference database includes a user-friendly, keyword-searchable, interface and only minimum knowledge of the use of Microsoft? Access is required.

  18. Homogeneity of the geochemical reference material BRP-1 (paraná basin basalt) and assessment of minimum mass

    USGS Publications Warehouse

    Cotta, Aloisio J. B.; Enzweiler, Jacinta; Wilson, Stephen A.; Perez, Carlos A.; Nardy, Antonio J. R.; Larizzatti, Joao H.

    2007-01-01

    Reference materials (RM) are required for quantitative analyses and their successful use is associated with the degree of homogeneity, and the traceability and confidence limits of the values established by characterisation. During the production of a RM, the chemical characterisation can only commence after it has been demonstrated that the material has the required level of homogeneity. Here we describe the preparation of BRP-1, a proposed geochemical reference material, and the results of the tests to evaluate its degree of homogeneity between and within bottles. BRP-1 is the first of two geochemical RM being produced by Brazilian institutions in collaboration with the United States Geological Survey (USGS) and the International Association of Geoanalysts (IAG). Two test portions of twenty bottles of BRP-1 were analysed by wavelength dispersive-XRF spectrometry and major, minor and eighteen trace elements were determined. The results show that for most of the investigated elements, the units of BRP-1 were homogeneous at conditions approximately three times more rigorous than those strived for by the test of “sufficient homogeneity”. Furthermore, the within bottle homogeneity of BRP-1 was evaluated using small beam (1 mm2) synchrotron radiation XRF spectrometry and, for comparison, the USGS reference materials BCR-2 and GSP-2 were also evaluated. From our data, it has been possible to assign representative minimum masses for some major constituents (1 mg) and for some trace elements (1-13 mg), except Zr in GSP-2, for which test portions of 74 mg are recommended.

  19. Characterizing Vaccinium berry Standard Reference Materials by GC-MS using NIST spectral libraries.

    PubMed

    Lowenthal, Mark S; Andriamaharavo, Nirina R; Stein, Stephen E; Phinney, Karen W

    2013-05-01

    A gas chromatography-mass spectrometry (GC-MS)-based method was developed for qualitative characterization of metabolites found in Vaccinium fruit (berry) dietary supplement Standard Reference Materials (SRMs). Definitive identifications are provided for 98 unique metabolites determined among six Vaccinium-related SRMs. Metabolites were enriched using an organic liquid/liquid extraction, and derivatized prior to GC-MS analysis. Electron ionization (EI) fragmentation spectra were searched against EI spectra of authentic standards compiled in the National Institute of Standards and Technology's mass spectral libraries, as well as spectra selected from the literature. Metabolite identifications were further validated using a retention index match along with prior probabilities and were compared with results obtained in a previous effort using collision-induced dissociation (CID) MS/MS datasets from liquid chromatography coupled to mass spectrometry experiments. This manuscript describes a nontargeted metabolite profile of Vaccinium materials, compares results among related materials and from orthogonal experimental platforms, and discusses the feasibility and development of using mass spectral library matching for nontargeted metabolite identification.

  20. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods.

    PubMed

    Shehata, A B; Rizk, M S; Rend, E A

    2016-10-01

    Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis. Copyright © 2016. Published by Elsevier B.V.

  1. Reference Books in Special Media. Reference Circular No. 82-4.

    ERIC Educational Resources Information Center

    Library of Congress, Washington, DC. National Library Service for the Blind and Physically Handicapped.

    Based on information contained in producers' catalogs and on responses to a survey conducted by the Reference Section of the Library of Congress National Library Service (NLS) for the Blind and Physically Handicapped, this publication lists reference materials produced in braille or in large type, and sound recordings of reference works available…

  2. Diagnostic articulation tables

    NASA Astrophysics Data System (ADS)

    Mikhailov, V. G.

    2002-09-01

    In recent years, considerable progress has been made in the development of instrumental methods for general speech quality and intelligibility evaluation on the basis of modeling the auditory perception of speech and measuring the signal-to-noise ratio. Despite certain advantages (fast measurement procedures with a low labor consumption), these methods are not universal and, in essence, secondary, because they rely on the calibration based on subjective-statistical measurements. At the same time, some specific problems of speech quality evaluation, such as the diagnostics of the factors responsible for the deviation of the speech quality from standard (e.g., accent features of a speaker or individual voice distortions), can be solved by psycholinguistic methods. This paper considers different kinds of diagnostic articulation tables: tables of minimal pairs of monosyllabic words (DRT) based on the Jacobson differential features, tables consisting of multisyllabic quartets of Russian words (the choice method), and tables of incomplete monosyllables of the _VC/CV_ type (the supplementary note method). Comparative estimates of the tables are presented along with the recommendations concerning their application.

  3. Statistical Analysis of a Round-Robin Measurement Survey of Two Candidate Materials for a Seebeck Coefficient Standard Reference Material

    PubMed Central

    Lu, Z. Q. J.; Lowhorn, N. D.; Wong-Ng, W.; Zhang, W.; Thomas, E. L.; Otani, M.; Green, M. L.; Tran, T. N.; Caylor, C.; Dilley, N. R.; Downey, A.; Edwards, B.; Elsner, N.; Ghamaty, S.; Hogan, T.; Jie, Q.; Li, Q.; Martin, J.; Nolas, G.; Obara, H.; Sharp, J.; Venkatasubramanian, R.; Willigan, R.; Yang, J.; Tritt, T.

    2009-01-01

    In an effort to develop a Standard Reference Material (SRM™) for Seebeck coefficient, we have conducted a round-robin measurement survey of two candidate materials—undoped Bi2Te3 and Constantan (55 % Cu and 45 % Ni alloy). Measurements were performed in two rounds by twelve laboratories involved in active thermoelectric research using a number of different commercial and custom-built measurement systems and techniques. In this paper we report the detailed statistical analyses on the interlaboratory measurement results and the statistical methodology for analysis of irregularly sampled measurement curves in the interlaboratory study setting. Based on these results, we have selected Bi2Te3 as the prototype standard material. Once available, this SRM will be useful for future interlaboratory data comparison and instrument calibrations. PMID:27504212

  4. 49 CFR Table 1 to Subpart B of... - Minimum Coefficient of Retroreflection (RA) (in Candela/Lux/Meter2) Requirement for...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) 1 Table 1 to Subpart B of Part 224 Transportation Other Regulations Relating to Transportation... ROLLING STOCK Application, Inspection, and Maintenance of Retroreflective Material Pt. 224, Subpt. B, Table 1 Table 1 to Subpart B of Part 224—Minimum Coefficient of Retroreflection (RA) (in Candela/Lux...

  5. 49 CFR Table 1 to Subpart B of... - Minimum Coefficient of Retroreflection (RA) (in Candela/Lux/Meter2) Requirement for...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) 1 Table 1 to Subpart B of Part 224 Transportation Other Regulations Relating to Transportation... ROLLING STOCK Application, Inspection, and Maintenance of Retroreflective Material Pt. 224, Subpt. B, Table 1 Table 1 to Subpart B of Part 224—Minimum Coefficient of Retroreflection (RA) (in Candela/Lux...

  6. HANFORD WASTE MINERALOGY REFERENCE REPORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DISSELKAMP RS

    2010-06-29

    This report lists the observed mineral phases present in the Hanford tanks. This task was accomplished by performing a review of numerous reports that used experimental techniques including, but not limited to: x-ray diffraction, polarized light microscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, electron energy loss spectroscopy, and particle size distribution analyses. This report contains tables that can be used as a quick reference to identify the crystal phases observed in Hanford waste.

  7. HANFORD WASTE MINEROLOGY REFERENCE REPORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DISSELKAMP RS

    2010-06-18

    This report lists the observed mineral phase phases present in the Hanford tanks. This task was accomplished by performing a review of numerous reports using experimental techniques including, but not limited to: x-ray diffraction, polarized light microscopy, scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, electron energy loss spectroscopy, and particle size distribution analyses. This report contains tables that can be used as a quick reference to identify the crystal phases present observed in Hanford waste.

  8. 238U/235U determinations of some commonly used reference materials and U-bearing accessory minerals (Invited)

    NASA Astrophysics Data System (ADS)

    Condon, D.; Noble, S.; McLean, N.; Bowring, S. A.

    2009-12-01

    We have determined 238U/235U ratios for a suite of commonly used natural (CRM 112a, SRM 950a, HU-1) and synthetic (IRMM 184 and CRM U500) uranium reference materials in addition to several U-bearing accessory phases (zircon and monazite) by thermal ionisation mass-spectrometry (TIMS) using the IRMM 3636 233U-236U double spike to accurately correct for mass fractionation. The 238U/235U values for the natural uranium reference materials differ, by up to 0.1%, from the widely used ‘consensus’ value (137.88) with all having 238U/235U values less than 137.88. Similarly, initial 238U/235U data from zircon and monazite yield 238U/235U values that are lower than the ‘consensus’ value. The data obtained from U-bearing minerals is used to assess how the uncertainty in the 238U/235U ratio contributes to the systematic discordance observed in 238U/206Pb and 235U/207Pb dates (Mattinson, 2000; Schoene et al., 2006) which has traditionally been wholly attributed to error in the U decay constants. The 238U/235U determinations made on the synthetic reference materials yield results that are considerably more precise and accurate than the certified values (0.02% vs. 0.1% for CRM U500). The calibration of isotopic tracers used for U-daughter geochronology that are partially based upon these reference materials, and the resultant age determinations, will benefit from increased accuracy and precision. Mattinson, J.M., 2000. Revising the “gold standard”—the uranium decay constants of Jaffey et al., 1971. Eos Trans. AGU, Spring Meet. Suppl., Abstract V61A-02. Schoene B., Crowley J.L., Condon D.C., Schmitz M.D., Bowring S.A., 2006, Reassessing the uranium decay constants for geochronology using ID-TIMS U-Pb data. Geochimica et Cosmochimica Acta 70: 426-445

  9. Characterization of 137 Genomic DNA Reference Materials for 28 Pharmacogenetic Genes

    PubMed Central

    Pratt, Victoria M.; Everts, Robin E.; Aggarwal, Praful; Beyer, Brittany N.; Broeckel, Ulrich; Epstein-Baak, Ruth; Hujsak, Paul; Kornreich, Ruth; Liao, Jun; Lorier, Rachel; Scott, Stuart A.; Smith, Chingying Huang; Toji, Lorraine H.; Turner, Amy; Kalman, Lisa V.

    2017-01-01

    Pharmacogenetic testing is increasingly available from clinical laboratories. However, only a limited number of quality control and other reference materials are currently available to support clinical testing. To address this need, the Centers for Disease Control and Prevention–based Genetic Testing Reference Material Coordination Program, in collaboration with members of the pharmacogenetic testing community and the Coriell Cell Repositories, has characterized 137 genomic DNA samples for 28 genes commonly genotyped by pharmacogenetic testing assays (CYP1A1, CYP1A2, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4, CYP3A5, CYP4F2, DPYD, GSTM1, GSTP1, GSTT1, NAT1, NAT2, SLC15A2, SLC22A2, SLCO1B1, SLCO2B1, TPMT, UGT1A1, UGT2B7, UGT2B15, UGT2B17, and VKORC1). One hundred thirty-seven Coriell cell lines were selected based on ethnic diversity and partial genotype characterization from earlier testing. DNA samples were coded and distributed to volunteer testing laboratories for targeted genotyping using a number of commercially available and laboratory developed tests. Through consensus verification, we confirmed the presence of at least 108 variant pharmacogenetic alleles. These samples are also being characterized by other pharmacogenetic assays, including next-generation sequencing, which will be reported separately. Genotyping results were consistent among laboratories, with most differences in allele assignments attributed to assay design and variability in reported allele nomenclature, particularly for CYP2D6, UGT1A1, and VKORC1. These publicly available samples will help ensure the accuracy of pharmacogenetic testing. PMID:26621101

  10. Production of highly-enriched 134Ba for a reference material for isotope dilution mass spectrometry measurements

    DOE PAGES

    Horkley, J. J.; Carney, K. P.; Gantz, E. M.; ...

    2015-03-17

    Isotope dilution mass spectrometry (IDMS) is an analytical technique capable of providing accurate and precise quantitation of trace isotope abundance and assay providing measurement uncertainties below 1 %. To achieve these low uncertainties, the IDMS method ideally utilizes chemically pure “spike” solutions that consist of a single highly enriched isotope that is well-characterized relating to the abundance of companion isotopes and concentration in solution. To address a current demand for accurate 137Cs/137Ba ratio measurements for “age” determination of radioactive 137Cs sources, Idaho National Laboratory (INL) is producing enriched 134Ba isotopes that are tobe used for IDMS spikes to accurately determinemore » 137Ba accumulation from the decay of 137Cs. The final objective of this work it to provide a homogenous set of reference materials that the National Institute of Standards and Technology can certify as standard reference materials used for IDMS. The process that was developed at INL for the separation and isolation of Ba isotopes, chemical purification of the isotopes in solution, and the encapsulation of the materials will be described.« less

  11. Development and application of a general plasmid reference material for GMO screening.

    PubMed

    Wu, Yuhua; Li, Jun; Wang, Yulei; Li, Xiaofei; Li, Yunjing; Zhu, Li; Li, Jun; Wu, Gang

    The use of analytical controls is essential when performing GMO detection through screening tests. Additionally, the presence of taxon-specific sequences is analyzed mostly for quality control during GMO detection. In this study, 11 commonly used genetic elements involving three promoters (P-35S, P-FMV35S and P-NOS), four marker genes (Bar, NPTII, HPT and Pmi), and four terminators (T-NOS, T-35S, T-g7 and T-e9), together with the reference gene fragments from six major crops of maize, soybean, rapeseed, rice, cotton and wheat, were co-integrated into the same single plasmid to construct a general reference plasmid pBI121-Screening. The suitability test of pBI121-Screening plasmid as reference material indicated that the non-target sequence on the pBI121-Screening plasmid did not affect the PCR amplification efficiencies of screening methods and taxon-specific methods. The sensitivity of screening and taxon-specific assays ranged from 5 to 10 copies of pBI121-Screening plasmid, meeting the sensitivity requirement of GMO detection. The construction of pBI121-Screening solves the lack of a general positive control for screening tests, thereby reducing the workload and cost of preparing a plurality of the positive control. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Investigation of Shock Wave Attenuation in Porous Materials

    DTIC Science & Technology

    2009-12-01

    Foam ...... 38 Table 4. Summary of Material Characteristics of Polyurethane Foams ............ 40 Table 5. Summary of Experiment Results...polyurethane foam , he performed a simple symmetric impact simulation to investigate the material properties and wave propagation characteristics of the...describes the characteristics of the two foam materials studied in this research, namely the aluminum metal foam and rigid polyurethane foam , which

  13. 30 CFR 75.501 - Permissible electric face equipment; coal seams above water table.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Permissible electric face equipment; coal seams... Equipment-General § 75.501 Permissible electric face equipment; coal seams above water table. [Statutory Provision] On and after March 30, 1974, all electric face equipment, other than equipment referred to in...

  14. Periodic reference tracking control approach for smart material actuators with complex hysteretic characteristics

    NASA Astrophysics Data System (ADS)

    Sun, Zhiyong; Hao, Lina; Song, Bo; Yang, Ruiguo; Cao, Ruimin; Cheng, Yu

    2016-10-01

    Micro/nano positioning technologies have been attractive for decades for their various applications in both industrial and scientific fields. The actuators employed in these technologies are typically smart material actuators, which possess inherent hysteresis that may cause systems behave unexpectedly. Periodic reference tracking capability is fundamental for apparatuses such as scanning probe microscope, which employs smart material actuators to generate periodic scanning motion. However, traditional controller such as PID method cannot guarantee accurate fast periodic scanning motion. To tackle this problem and to conduct practical implementation in digital devices, this paper proposes a novel control method named discrete extended unparallel Prandtl-Ishlinskii model based internal model (d-EUPI-IM) control approach. To tackle modeling uncertainties, the robust d-EUPI-IM control approach is investigated, and the associated sufficient stabilizing conditions are derived. The advantages of the proposed controller are: it is designed and represented in discrete form, thus practical for digital devices implementation; the extended unparallel Prandtl-Ishlinskii model can precisely represent forward/inverse complex hysteretic characteristics, thus can reduce modeling uncertainties and benefits controllers design; in addition, the internal model principle based control module can be utilized as a natural oscillator for tackling periodic references tracking problem. The proposed controller was verified through comparative experiments on a piezoelectric actuator platform, and convincing results have been achieved.

  15. Trace elements in a commercial freeze-dried human urine reference material.

    PubMed

    Veillon, C; Patterson, K Y

    1996-07-01

    A large batch of freeze-dried human urine reference material, Seronorm Trace Elements Urine, Lot 101021, was prepared commercially (Nycomed Pharma AS, Oslo, Norway) for quality control purposes in trace element analysis. Analytes are being determined by a voluntary, international co-operative effort so that the material will be available to the scientific community at modest cost. The material is in stoppered glass vials and is to be reconstituted with 5.00 ml of water prior to use. We have evaluated the trace element content for several elements, including chromium and zinc, elements for which we have two independent methods available for the determinations, namely isotope dilution mass spectrometry (IDMS) and atomic absorption spectrometry (AAS). We also report on other trace elements measured by IDMS alone, such as Se, for which we have enriched stable isotopes available. Results for chromium indicate a mean +/- standard deviation (n = 10) of 1.2 +/- 0.3 (by IDMS) and 1.4 +/- 0.3 (by AAS) ng Cr per ml of reconstituted urine, indicating possible inhomogeneity and/or contamination (21-25% relative standard deviation, RSD). Approximately half of the observed chromium originates from the sample container. The values observed for zinc were 590 +/- 90 ng ml-1 (15% RSD) for freshly reconstituted material, 760 +/- 60 ng ml-1 (8% RSD) for material reconstituted 4 d earlier, and 940 +/- 60 ng ml-1 (6% RSD) 2 months after reconstitution. Selenium values by IDMS were very reproducible, with a mean concentration of 16 +/- 0.15 ng g-1 (0.9% RSD), suggesting little or no contamination and a high degree of sample homogeneity for this element. The source of potential contaminants has been evaluated by multielement determinations of leachates of the vials and stoppers. Elements noted in significant amounts include B, Ba, Sr, Mo, Cu and Zn, with most of the zinc coming from the rubber stopper.

  16. Measurement of the high-temperature Seebeck coefficient of thin films by means of an epitaxially regrown thermometric reference material.

    PubMed

    Ramu, Ashok T; Mages, Phillip; Zhang, Chong; Imamura, Jeffrey T; Bowers, John E

    2012-09-01

    The Seebeck coefficient of a typical thermoelectric material, silicon-doped InGaAs lattice-matched to InP, is measured over a temperature range from 300 K to 550 K. By depositing and patterning a thermometric reference bar of silicon-doped InP adjacent to a bar of the material under test, temperature differences are measured directly. This is in contrast to conventional two-thermocouple techniques that subtract two large temperatures to yield a small temperature difference, a procedure prone to errors. The proposed technique retains the simple instrumentation of two-thermocouple techniques while eliminating the critical dependence of the latter on good thermal contact. The repeatability of the proposed technique is demonstrated to be ±2.6% over three temperature sweeps, while the repeatability of two-thermocouple measurements is about ±5%. The improved repeatability is significant for reliable reporting of the ZT figure of merit, which is proportional to the square of the Seebeck coefficient. The accuracy of the proposed technique depends on the accuracy with which the high-temperature Seebeck coefficient of the reference material may be computed or measured. In this work, the Seebeck coefficient of the reference material, n+ InP, is computed by rigorous solution of the Boltzmann transport equation. The accuracy and repeatability of the proposed technique can be systematically improved by scaling, and the method is easily extensible to other material systems currently being investigated for high thermoelectric energy conversion efficiency.

  17. Cross-reference identification within a PDF document

    NASA Astrophysics Data System (ADS)

    Li, Sida; Gao, Liangcai; Tang, Zhi; Yu, Yinyan

    2015-01-01

    Cross-references, such like footnotes, endnotes, figure/table captions, references, are a common and useful type of page elements to further explain their corresponding entities in the target document. In this paper, we focus on cross-reference identification in a PDF document, and present a robust method as a case study of identifying footnotes and figure references. The proposed method first extracts footnotes and figure captions, and then matches them with their corresponding references within a document. A number of novel features within a PDF document, i.e., page layout, font information, lexical and linguistic features of cross-references, are utilized for the task. Clustering is adopted to handle the features that are stable in one document but varied in different kinds of documents so that the process of identification is adaptive with document types. In addition, this method leverages results from the matching process to provide feedback to the identification process and further improve the algorithm accuracy. The primary experiments in real document sets show that the proposed method is promising to identify cross-reference in a PDF document.

  18. Feasibility study on production of a matrix reference material for cyanobacterial toxins.

    PubMed

    Hollingdale, Christie; Thomas, Krista; Lewis, Nancy; Békri, Khalida; McCarron, Pearse; Quilliam, Michael A

    2015-07-01

    The worldwide increase in cyanobacterial contamination of freshwater lakes and rivers is of great concern as many cyanobacteria produce potent hepatotoxins and neurotoxins (cyanotoxins). Such toxins pose a threat to aquatic ecosystems, livestock, and drinking water supplies. In addition, dietary supplements prepared from cyanobacteria can pose a risk to consumers if they contain toxins. Analytical monitoring for toxins in the environment and in consumer products is essential for the protection of public health. Reference materials (RMs) are an essential tool for the development and validation of analytical methods and are necessary for ongoing quality control of monitoring operations. Since the availability of appropriate RMs for cyanotoxins has been very limited, the present study was undertaken to examine the feasibility of producing a cyanobacterial matrix RM containing various cyanotoxins. The first step was large-scale culturing of various cyanobacterial cultures that produce anatoxins, microcystins, and cylindrospermopsins. After harvesting, the biomass was lyophilized, blended, homogenized, milled, and bottled. The moisture content and physical characteristics were assessed in order to evaluate the effectiveness of the production process. Toxin levels were measured by liquid chromatography with tandem mass spectrometry and ultraviolet detection. The reference material was found to be homogeneous for toxin content. Stability studies showed no significant degradation of target toxins over a period of 310 days at temperatures up to +40 °C except for the anatoxin-a, which showed some degradation at +40 °C. These results show that a fit-for-purpose matrix RM for cyanotoxins can be prepared using the processes and techniques applied in this work.

  19. 47 CFR 73.698 - Tables.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Tables. 73.698 Section 73.698 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES Television Broadcast Stations § 73.698 Tables. Table I [Reserved] Table II (1)—Channel (2)—31.4 kilometers (19.5 miles...

  20. Production development of organic nonflammable spacecraft potting encapsulating and conformal coating compounds. Volume 2: Tables

    NASA Technical Reports Server (NTRS)

    Lieberman, S. L.

    1974-01-01

    Tables are presented which include: material properties; elemental analysis; silicone RTV formulations; polyester systems and processing; epoxy preblends and processing; urethane materials and processing; epoxy-urethanes elemental analysis; flammability test results, and vacuum effects.

  1. Periodic Table of Students.

    ERIC Educational Resources Information Center

    Johnson, Mike

    1998-01-01

    Presents an exercise in which an eighth-grade science teacher decorated the classroom with a periodic table of students. Student photographs were arranged according to similarities into vertical columns. Students were each assigned an atomic number according to their placement in the table. The table is then used to teach students about…

  2. Nondestructive Evaluation of Airport Pavements. Volume I. Program References,

    DTIC Science & Technology

    1979-09-01

    greater than its original capacity (see test 13 on Fig. 2.5). During the material tests by Majidzadeh, the dynamic E-value of frozen subgrade soil was...Sample the base and subbase material by conventional spoon and identify the material by standard soil -aggregate classification and penetration...such as shaker table. The new testing specification is designed for all paving materials including subgrade soils . The specifications of material

  3. Synthetic musk fragrances in environmental Standard Reference Materials.

    PubMed

    Peck, Aaron M; Kucklick, John R; Schantz, Michele M

    2007-04-01

    Synthetic musk fragrances have been measured in water, air, sediments, sewage sludge, and biota worldwide. As the study of the environmental fate and impacts of these compounds progresses, the need for Standard Reference Materials (SRMs) for these compounds to facilitate analytical method improvement and interlaboratory comparisons becomes increasingly important. The National Institute of Standards and Technology (NIST) issues environmental matrix SRMs with certified concentrations for a variety of persistent organic pollutants including polycyclic aromatic hydrocarbons (PAHs), chlorinated pesticides, and polychlorinated biphenyl congeners (PCBs). Until now synthetic musk fragrance concentrations have not been reported in NIST SRMs. The objective of this study was to provide reference values for several commonly detected synthetic musk fragrances in several NIST natural matrix SRMs. In this study five polycyclic musk fragrances [HHCB (1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethylcyclopenta-gamma-2-benzopyran), AHTN (7-acetyl-1,1,3,4,4,6-hexamethyl-1,2,3,4-tetrahydronaphthalene), ADBI (4-acetyl-1,1-dimethyl-6-tert-butylindane), AHMI (6-acetyl-1,1,2,3,3,5-hexamethylindane), and ATII (5-acetyl-1,1,2,6-tetramethyl-3-isopropylindane] and two nitro musk fragrances [musk xylene (1-tert-butyl-3,5-dimethyl-2,4,6-trinitrobenzene) and musk ketone (4-tert-butyl-3,5-dinitro-2,6-dimethylacetophenone)] were measured in selected environmental SRMs. Gas chromatography-electron impact mass spectrometry (GC/EI-MS) was used for all analyses. HHCB was the most frequently detected synthetic musk fragrance and was detected in SRM 2585 Organic Contaminants in House Dust, SRM 2781 Domestic Sludge, SRM 1974b Organics in Mussel Tissue (Mytilus edulis), and SRM 1947 Lake Michigan Fish Tissue. It was not detected in SRM 1946 Lake Superior Fish Tissue or SRM 1945 Organics in Whale Blubber. Concentrations of HHCB in these SRMs ranged from 1.12 ng/g in SRM 1947 to 92,901 ng/g in SRM 2781. All of

  4. Three new mussel tissue standard reference materials (SRMs) for the determination of organic contaminants.

    PubMed

    Poster, Dianne L; Schantz, Michele M; Kucklick, John R; Lopez de Alda, Maria J; Porter, Barbara J; Pugh, Rebecca; Wise, Stephen A

    2004-03-01

    Three new mussel tissue standard reference materials (SRMs) have been developed by the National Institute of Standards and Technology (NIST) for the determination of the concentrations of organic contaminants. The most recently prepared material, SRM 1974b, is a fresh frozen tissue homogenate prepared from mussels ( Mytilus edulis) collected in Boston Harbor, Massachusetts. The other two materials, SRMs 2977 and 2978, are freeze-dried tissue homogenates prepared from mussels collected in Guanabara Bay, Brazil and Raritan Bay, New Jersey, respectively. All three new mussel tissue SRMs complement the current suite of marine natural-matrix SRMs available from NIST that are characterized for a wide range of contaminants (organic and inorganic). SRM 1974b has been developed to replace its predecessor SRM 1974a, Organics in Mussel Tissue, for which the supply is depleted. Similarly, SRMs 2977 and 2978 were developed to replace a previously available (supply depleted) freeze-dried version of SRM 1974a, SRM 2974, Organics in Freeze-Dried Mussel Tissue. SRM 1974b is the third in a series of fresh frozen mussel tissue homogenate SRMs prepared from mussels collected in Boston Harbor starting in 1988. SRM 1974b has certified concentration values for 22 polycyclic aromatic hydrocarbons (PAHs), 31 polychlorinated biphenyl congeners (PCBs), and 7 chlorinated pesticides. Reference values are provided for additional constituents: 16 PAHs, 8 PCBs plus total PCBs, 6 pesticides, total extractable organics, methylmercury, and 11 trace elements. PAH concentrations range from about 2 ng g(-1 )dry mass (cyclopenta[ cd]pyrene) to 180 ng g(-1 )dry mass (pyrene). PCB concentrations range from about 2 ng g(-1 )dry mass (PCB 157) to 120 ng g(-1 )dry mass (PCB 153). The reference value for total PCBs in SRM 1974b is (2020 +/- 420) ng g(-1 )dry mass. Pesticide concentrations range from about 4 ng g(-1 )dry mass (4,4'-DDT) to 40 ng g(-1 )dry mass (4,4'-DDE). SRM 2977 has certified values for 14

  5. Oxygen isotopes in nitrate: New reference materials for 18O:17O:16O measurements and observations on nitrate-water equilibration

    USGS Publications Warehouse

    Böhlke, J.K.; Mroczkowski, S.J.; Coplen, T.B.

    2003-01-01

    Despite a rapidly growing literature on analytical methods and field applications of O isotope-ratio measurements of NO3− in environmental studies, there is evidence that the reported data may not be comparable because reference materials with widely varying δ18O values have not been readily available. To address this problem, we prepared large quantities of two nitrate salts with contrasting O isotopic compositions for distribution as reference materials for O isotope-ratio measurements: USGS34 (KNO3) with low δ18O and USGS35 (NaNO3) with high δ18O and ‘mass-independent’ δ17O. The procedure used to produce USGS34 involved equilibration of HNO3 with 18O-depleted meteoric water. Nitric acid equilibration is proposed as a simple method for producing laboratory NO3− reference materials with a range of δ18O values and normal (mass-dependent) 18O:17O:16O variation. Preliminary data indicate that the equilibrium O isotope-fractionation factor (α) between [NO3−] and H2O decreases with increasing temperature from 1.0215 at 22°C to 1.0131 at 100°C. USGS35 was purified from the nitrate ore deposits of the Atacama Desert in Chile and has a high 17O:18O ratio owing to its atmospheric origin. These new reference materials, combined with previously distributed NO3− isotopic reference materials IAEA-N3 (=IAEA-NO-3) and USGS32, can be used to calibrate local laboratory reference materials for determining offset values, scale factors, and mass-independent effects on N and O isotope-ratio measurements in a wide variety of environmental NO3− samples. Preliminary analyses yield the following results (normalized with respect to VSMOW and SLAP, with reproducibilities of ±0.2–0.3‰, 1σ): IAEA-N3 has δ18O = +25.6‰ and δ17O = +13.2‰; USGS32 has δ18O = +25.7‰; USGS34 has δ18O = −27.9‰ and δ17O = −14.8‰; and USGS35 has δ18O = +57.5‰ and δ17O = +51.5‰.

  6. Empirical yield tables for Minnesota.

    Treesearch

    Jerold T. Hahn; Gerhard K. Raile

    1982-01-01

    Describes the tables derived from the 1977 Forest Survey of Minnesota and presents examples of how the tables can be used. These tables are broken down according to Minnesota's four Forest Survey Units, 14 forest types, and 5 site index classes. Presents 210 of the 350 possible tables that contained sufficient data to justify publication.

  7. Use of gelatin gels as a reference material for performance evaluation of meat shear force measurements

    USDA-ARS?s Scientific Manuscript database

    Establishing standards for meat tenderness based on Warner-Bratzler shear force (WBSF) is complicated by the lack of methods for certifying WBSF testing among texture systems or laboratories. The objective of this study was to determine the suitability of using gelatin gels as a reference material ...

  8. 40 CFR Table C-4 to Subpart C of... - Test Specifications for PM 10, PM 2.5 and PM 10-2.5 Candidate Equivalent Methods

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Test Specifications for PM 10, PM 2.5 and PM 10-2.5 Candidate Equivalent Methods C Table C-4 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-4 Table C-4 to Subpart C of Part 53—Test Specifications for PM...

  9. 40 CFR Table C-4 to Subpart C of... - Test Specifications for PM 10, PM 2.5 and PM 10-2.5 Candidate Equivalent Methods

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Test Specifications for PM 10, PM 2.5 and PM 10-2.5 Candidate Equivalent Methods C Table C-4 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-4 Table C-4 to Subpart C of Part 53—Test Specifications for PM...

  10. RADIOACTIVE ELEMENTS IN THE STANDARD ATOMIC WEIGHTS TABLE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holden, N.E.; Holden, N.; Holden,N.E.

    2011-07-27

    composition, from which an atomic weight value could be calculated to five or more figure accuracy, without prior knowledge of the sample involved. These elements were again listed in the Atomic Weights Table with no further information, i.e., with no mass number or atomic weight value. For the elements, which have no stable characteristic terrestrial isotopic composition, the data on the half-lives and the relative atomic masses for the nuclides of interest for those elements have been evaluated. The values of the half-lives with their uncertainties are listed in the table. The uncertainties are given for the last digit quoted of the half-life and are given in parentheses. A half-life entry for the Table having a value and an uncertainty of 7 {+-} 3 is listed in the half-life column as 7 (3). The criteria to include data in this Table, is to be the same as it has been for over sixty years. It is the same criteria, which are used for all data that are evaluated for inclusion in the Standard Table of Atomic Weights. If a report of data is published in a peer-reviewed journal, that data is evaluated and considered for inclusion in the appropriate table of the biennial report of the Atomic Weights Commission. As better data becomes available in the future, the information that is contained in either of the Tables of Standard Atomic Weights or in the Table of Radioactive Elements may be modified. It should be noted that the appearance of any datum in the Table of the Radioactive Elements is merely for the purposes of calculating an atomic mass value for any sample of a radioactive material, which might have a variety of isotopic compositions and it has no implication as to the priority for claiming discovery of a given element and is not intended to. The atomic mass values have been taken primarily from the 2003 Atomic Mass Table. Mass values for those radioisotopes that do not appear in the 2003 Atomic mass Table have been taken from preliminary data of the Atomic Mass Data

  11. Large field of view quantitative phase imaging of induced pluripotent stem cells and optical pathlength reference materials

    NASA Astrophysics Data System (ADS)

    Kwee, Edward; Peterson, Alexander; Stinson, Jeffrey; Halter, Michael; Yu, Liya; Majurski, Michael; Chalfoun, Joe; Bajcsy, Peter; Elliott, John

    2018-02-01

    Induced pluripotent stem cells (iPSCs) are reprogrammed cells that can have heterogeneous biological potential. Quality assurance metrics of reprogrammed iPSCs will be critical to ensure reliable use in cell therapies and personalized diagnostic tests. We present a quantitative phase imaging (QPI) workflow which includes acquisition, processing, and stitching multiple adjacent image tiles across a large field of view (LFOV) of a culture vessel. Low magnification image tiles (10x) were acquired with a Phasics SID4BIO camera on a Zeiss microscope. iPSC cultures were maintained using a custom stage incubator on an automated stage. We implement an image acquisition strategy that compensates for non-flat illumination wavefronts to enable imaging of an entire well plate, including the meniscus region normally obscured in Zernike phase contrast imaging. Polynomial fitting and background mode correction was implemented to enable comparability and stitching between multiple tiles. LFOV imaging of reference materials indicated that image acquisition and processing strategies did not affect quantitative phase measurements across the LFOV. Analysis of iPSC colony images demonstrated mass doubling time was significantly different than area doubling time. These measurements were benchmarked with prototype microsphere beads and etched-glass gratings with specified spatial dimensions designed to be QPI reference materials with optical pathlength shifts suitable for cell microscopy. This QPI workflow and the use of reference materials can provide non-destructive traceable imaging method for novel iPSC heterogeneity characterization.

  12. Development of a candidate reference material for adventitious virus detection in vaccine and biologicals manufacturing by deep sequencing

    PubMed Central

    Mee, Edward T.; Preston, Mark D.; Minor, Philip D.; Schepelmann, Silke; Huang, Xuening; Nguyen, Jenny; Wall, David; Hargrove, Stacey; Fu, Thomas; Xu, George; Li, Li; Cote, Colette; Delwart, Eric; Li, Linlin; Hewlett, Indira; Simonyan, Vahan; Ragupathy, Viswanath; Alin, Voskanian-Kordi; Mermod, Nicolas; Hill, Christiane; Ottenwälder, Birgit; Richter, Daniel C.; Tehrani, Arman; Jacqueline, Weber-Lehmann; Cassart, Jean-Pol; Letellier, Carine; Vandeputte, Olivier; Ruelle, Jean-Louis; Deyati, Avisek; La Neve, Fabio; Modena, Chiara; Mee, Edward; Schepelmann, Silke; Preston, Mark; Minor, Philip; Eloit, Marc; Muth, Erika; Lamamy, Arnaud; Jagorel, Florence; Cheval, Justine; Anscombe, Catherine; Misra, Raju; Wooldridge, David; Gharbia, Saheer; Rose, Graham; Ng, Siemon H.S.; Charlebois, Robert L.; Gisonni-Lex, Lucy; Mallet, Laurent; Dorange, Fabien; Chiu, Charles; Naccache, Samia; Kellam, Paul; van der Hoek, Lia; Cotten, Matt; Mitchell, Christine; Baier, Brian S.; Sun, Wenping; Malicki, Heather D.

    2016-01-01

    Background Unbiased deep sequencing offers the potential for improved adventitious virus screening in vaccines and biotherapeutics. Successful implementation of such assays will require appropriate control materials to confirm assay performance and sensitivity. Methods A common reference material containing 25 target viruses was produced and 16 laboratories were invited to process it using their preferred adventitious virus detection assay. Results Fifteen laboratories returned results, obtained using a wide range of wet-lab and informatics methods. Six of 25 target viruses were detected by all laboratories, with the remaining viruses detected by 4–14 laboratories. Six non-target viruses were detected by three or more laboratories. Conclusion The study demonstrated that a wide range of methods are currently used for adventitious virus detection screening in biological products by deep sequencing and that they can yield significantly different results. This underscores the need for common reference materials to ensure satisfactory assay performance and enable comparisons between laboratories. PMID:26709640

  13. 40 CFR Table 1 to Subpart IIIii of... - Work Practice Standards-Design, Operation, and Maintenance Requirements

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 1 Table 1 to... . . . 1. Cell rooms a. For new or modified cell rooms, construct each cell room interior using materials... mercury spills or accumulations, and are easy to clean. b. Limit access around and beneath mercury cells...

  14. Realtime Hourly Data Table

    Science.gov Websites

    Tables View the latest hourly text summary CLICK ON UNDERLINED HOUR / SHADED BOX FOR THE LATEST CYCLE 00z Dump Tables View the latest rap text summary CLICK ON UNDERLINED HOUR / SHADED BOX FOR THE LATEST CYCLE Data Dump Tables View the latest model data text summary NAM GFS GDS CLICK ON UNDERLINED HOUR / SHADED

  15. Vibration Damping Response of Composite Materials

    DTIC Science & Technology

    1991-04-01

    using a diamond-impregnated cutoff wheel mounted on a milling machine . This procedure was followed to minimize damage to the composite specimens prior to...Development Report Vibration Damping Response of Composite Materials by Roger M. Crane 0E DTIC0 • ELECTE 16 - MAY 28 19914S8 0 E 5; 91--00524 Approved for...Damping Response of Composite Materials by Roger M. Crane TABLE OF CONTENTS Page LIST OF TABLES

  16. Evolution and perspectives of cultivar identification and traceability from tree to oil and table olives by means of DNA markers.

    PubMed

    Pasqualone, Antonella; Montemurro, Cinzia; di Rienzo, Valentina; Summo, Carmine; Paradiso, Vito Michele; Caponio, Francesco

    2016-08-01

    In recent years, an increasing number of typicality marks has been awarded to high-quality olive oils produced from local cultivars. In this case, quality control requires effective varietal checks of the starting materials. Moreover, accurate cultivar identification is essential in vegetative-propagated plants distributed by nurseries and is a pre-requisite to register new cultivars. Food genomics provides many tools for cultivar identification and traceability from tree to oil and table olives. The results of the application of different classes of DNA markers to olive with the purpose of checking cultivar identity and variability of plant material are extensively discussed in this review, with special regard to repeatability issues and polymorphism degree. The characterization of olive germplasm from all countries of the Mediterranean basin and from less studied geographical areas is described and innovative high-throughput molecular tools to manage reference collections are reviewed. Then the transferability of DNA markers to processed products - virgin olive oils and table olives - is overviewed to point out strengths and weaknesses, with special regard to (i) the influence of processing steps and storage time on the quantity and quality of residual DNA, (ii) recent advances to overcome the bottleneck of DNA extraction from processed products, (iii) factors affecting whole comparability of DNA profiles between fresh plant materials and end-products, (iv) drawbacks in the analysis of multi-cultivar versus single-cultivar end-products and (v) the potential of quantitative polymerase chain reaction (PCR)-based techniques. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  17. Recovery of PET from packaging plastics mixtures by wet shaking table.

    PubMed

    Carvalho, M T; Agante, E; Durão, F

    2007-01-01

    Recycling requires the separation of materials appearing in a mass of wastes of heterogeneous composition and characteristics, into single, almost pure, component/material flows. The separation of materials (e.g., some types of plastics) with similar physical properties (e.g., specific gravity) is often accomplished by human sorting. This is the case of the separation of packaging plastics in municipal solid wastes (MSW). The low cost of virgin plastics and low value of recycled plastics necessitate the utilization of low cost techniques and processes in the recycling of packaging plastics. An experimental study was conducted to evaluate the feasibility of production of a PET product, cleaned from PVC and PS, using a wet shaking table. The wet shaking table is an environmentally friendly process, widely used to separate minerals, which has low capital and operational costs. Some operational variables of the equipment, as well as different feed characteristics, were considered. The results show that the separation of these plastics is feasible although, similarly to the mineral field, in somewhat complex flow sheets.

  18. Role of chromatography in the development of Standard Reference Materials for organic analysis.

    PubMed

    Wise, Stephen A; Phinney, Karen W; Sander, Lane C; Schantz, Michele M

    2012-10-26

    The certification of chemical constituents in natural-matrix Standard Reference Materials (SRMs) at the National Institute of Standards and Technology (NIST) can require the use of two or more independent analytical methods. The independence among the methods is generally achieved by taking advantage of differences in extraction, separation, and detection selectivity. This review describes the development of the independent analytical methods approach at NIST, and its implementation in the measurement of organic constituents such as contaminants in environmental materials, nutrients and marker compounds in food and dietary supplement matrices, and health diagnostic and nutritional assessment markers in human serum. The focus of this review is the important and critical role that separation science techniques play in achieving the necessary independence of the analytical steps in the measurement of trace-level organic constituents in natural matrix SRMs. Published by Elsevier B.V.

  19. A PROCEDURE FOR ESTABLISHING TRACEABILITY OF GAS MIXTURES TO CERTAIN NATIONAL BUREAU OF STANDARDS STANDARD REFERENCE MATERIALS

    EPA Science Inventory

    This procedure includes the specifications and requirements that must be followed by gas manufacturers during the preparation of compressed cylinder gas Certified Reference Materials (CRM). A CRM is a certified gas standard prepared at a concentration that does not exceed + or - ...

  20. Liquid chromatography with absorbance detection and with isotope-dilution mass spectrometry for determination of isoflavones in soy standard reference materials.

    PubMed

    Phillips, Melissa M; Bedner, Mary; Reitz, Manuela; Burdette, Carolyn Q; Nelson, Michael A; Yen, James H; Sander, Lane C; Rimmer, Catherine A

    2017-02-01

    Two independent analytical approaches, based on liquid chromatography with absorbance detection and liquid chromatography with mass spectrometric detection, have been developed for determination of isoflavones in soy materials. These two methods yield comparable results for a variety of soy-based foods and dietary supplements. Four Standard Reference Materials (SRMs) have been produced by the National Institute of Standards and Technology to assist the food and dietary supplement community in method validation and have been assigned values for isoflavone content using both methods. These SRMs include SRM 3234 Soy Flour, SRM 3236 Soy Protein Isolate, SRM 3237 Soy Protein Concentrate, and SRM 3238 Soy-Containing Solid Oral Dosage Form. A fifth material, SRM 3235 Soy Milk, was evaluated using the methods and found to be inhomogeneous for isoflavones and unsuitable for value assignment. Graphical Abstract Separation of six isoflavone aglycones and glycosides found in Standard Reference Material (SRM) 3236 Soy Protein Isolate.

  1. USEEIO Satellite Tables

    EPA Pesticide Factsheets

    These files contain the environmental data as particular emissions or resources associated with a BEA sectors that are used in the USEEIO model. They are organized by the emission or resources type, as described in the manuscript. The main files (without SI) show the final satellite tables in the 'Exchanges' sheet which have emissions or resource use per USD for 2013. The other sheets in these files provide meta data for the create of the tables, including general information, sources, etc. The 'export' sheet is used for saving the satellite table for csv export. The data dictionary describes the fields in this sheet. The supporting files provide all the details data transformation and organization for the development of the satellite tables.This dataset is associated with the following publication:Yang, Y., W. Ingwersen, T. Hawkins, and D. Meyer. USEEIO: a New and Transparent United States Environmentally Extended Input-Output Model. JOURNAL OF CLEANER PRODUCTION. Elsevier Science Ltd, New York, NY, USA,

  2. Reference Materials in LIS Instruction: A Delphi Study

    ERIC Educational Resources Information Center

    Rabina, Debbie

    2013-01-01

    This paper presents the results of a Delphi study conducted over a two-month period in 2011. The purpose of the study was to identify reference sources that should be covered in basic reference courses taught in LIS programs in the United States. The Delphi method was selected for its appropriateness in soliciting expert opinions and assessing the…

  3. USGS48 Puerto Rico precipitation - A new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Qi, Haiping; Coplen, Tyler B.; Tarbox, Lauren V.; Lorenz, Jennifer M.; Scholl, Martha A.

    2014-01-01

    A new secondary isotopic reference material has been prepared from Puerto Rico precipitation, which was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material, designated as USGS48, is intended to be one of two isotopic reference waters for daily normalisation of stable hydrogen (δ2H) and stable oxygen (δ18O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The δ2H and δ18O values of this reference water are−2.0±0.4 and−2.224±0.012 ‰, respectively, relative to Vienna Standard Mean Ocean Water on scales normalised such that the δ2H and δ18O values of Standard Light Antarctic Precipitation reference water are−428 and−55.5 ‰, respectively. Each uncertainty is an estimated expanded uncertainty (U=2uc) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. This isotopic reference water is available by the case of 144 glass ampoules containing 5 mL of water in each ampoule.

  4. Empirical yield tables for Wisconsin.

    Treesearch

    Jerold T. Hahn; Joan M. Stelman

    1989-01-01

    Describes the tables derived from the 1983 Forest Survey of Wisconsin and presents ways the tables can be used. These tables are broken down according to Wisconsin`s five Forest Survey Units and 14 forest types.

  5. Determination of Trace Level Iodine in Biological and Botanical Reference Materials by Isotope Dilution Mass Spectrometry

    PubMed Central

    Gramlich, John W.; Murphy, Thomas J.

    1989-01-01

    A method has been developed for the determination of trace level iodine in biological and botanical materials. The method consists of spiking a sample with 129I, equilibration of the spike with the natural iodine, wet ashing under carefully controlled conditions, and separation of the iodine by co-precipitation with silver chloride. Measurement of the 129I/127I ratio is accomplished by negative thermal ionization mass spectrometry using LaB6 for ionization enhancement. The application of the method to the certification of trace iodine in two Standard Reference Materials is described. PMID:28053411

  6. New Tables For IABG's 320kN Shaker System: Design And Procurement Process

    NASA Astrophysics Data System (ADS)

    Baumgartl, Ralf

    2012-07-01

    For more than 25 years IABG is operating its 320kN vibration system in testing of space and non-space applications. The vibration system is a multi shaker system, using four electrodynamic shakers, driving a 3x3m2 head expander and a 3x3m2 slip table. During the recent years a modernisation program of the shaker system has been implemented. The purpose of this program was to exchange system components, which have reached their expected duration of life, as well as to exchange components which did no longer fulfil the state-of-the-art requirements in testing and thus to adapt the vibration system to future challenges. Two major components of the shaker system, which have been covered during the modernisation program, are the shaker tables (the head expander and the slip table). Being the direct interface of a vibration test facility to a specimen, the shaker tables are crucial regarding the shaker system overall performance. And this fact applies even more for shaker systems with large tables, because there are no off-the-shelf solutions in this area. During the recent 5 years IABG specified, designed and procured a new head expander and a new slip table for the 320kN shaker system. This paper describes the overall process investigating on the following listed aspects: - general requirements for the tables - definition of boundary conditions and guidance principles - specific areas of interest - definition of the table material and the manufacturing method - design solutions - challenges during manufacturing - results - table properties

  7. Empirical yield tables for Michigan.

    Treesearch

    Jerold T. Hahn; Joan M. Stelman

    1984-01-01

    Describes the tables derived from the 1980 Forest Survey of Michigan and presents ways the tables can be used. These tables are broken down according to Michigan's four Forest Survey Units, 14 forest types, and 5 site-index classes.

  8. A new isotopic reference material for stable hydrogen and oxygen isotope-ratio measurements of water—USGS50 Lake Kyoga Water

    USGS Publications Warehouse

    Coplen, Tyler B.; Wassenaar, Leonard I; Mukwaya, Christine; Qi, Haiping; Lorenz, Jennifer M.

    2015-01-01

    This isotopic reference material, designated as USGS50, is intended as one of two reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer, of use especially for isotope-hydrology laboratories analyzing freshwater samples from equatorial and tropical regions.

  9. 40 CFR Table 3 to Subpart Eeee of... - Operating Limits-High Throughput Transfer Racks

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... with adsorbent regeneration to comply with an emission limit in table 2 to this subpart a. Maintain the... compliance with the emission limit; OR b. Maintain the total regeneration stream mass flow during the adsorption bed regeneration cycle greater than or equal to the reference stream mass flow established during...

  10. 40 CFR Table 3 to Subpart Eeee of... - Operating Limits-High Throughput Transfer Racks

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... with adsorbent regeneration to comply with an emission limit in table 2 to this subpart a. Maintain the... compliance with the emission limit; OR b. Maintain the total regeneration stream mass flow during the adsorption bed regeneration cycle greater than or equal to the reference stream mass flow established during...

  11. 40 CFR Table 3 to Subpart Eeee of... - Operating Limits-High Throughput Transfer Racks

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... with adsorbent regeneration to comply with an emission limit in table 2 to this subpart a. Maintain the... compliance with the emission limit; OR b. Maintain the total regeneration stream mass flow during the adsorption bed regeneration cycle greater than or equal to the reference stream mass flow established during...

  12. Solar cell efficiency tables (version 48): Solar cell efficiency tables (version 48)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, Martin A.; Emery, Keith; Hishikawa, Yoshihiro

    Consolidated tables showing an extensive listing of the highest independently confirmed efficiencies for solar cells and modules are presented. Guidelines for inclusion of results into these tables are outlined, and new entries since January 2016 are reviewed.

  13. Characteristics of Tables for Disseminating Biobehavioral Results.

    PubMed

    Schneider, Barbara St Pierre; Nagelhout, Ed; Feng, Du

    2018-01-01

    To report the complexity and richness of study variables within biological nursing research, authors often use tables; however, the ease with which consumers understand, synthesize, evaluate, and build upon findings depends partly upon table design. To assess and compare table characteristics within research and review articles published in Biological Research for Nursing and Nursing Research. A total of 10 elements in tables from 48 biobehavioral or biological research or review articles were analyzed. To test six hypotheses, a two-level hierarchical linear model was used for each of the continuous table elements, and a two-level hierarchical generalized linear model was used for each of the categorical table elements. Additionally, the inclusion of probability values in statistical tables was examined. The mean number of tables per article was 3. Tables in research articles were more likely to contain quantitative content, while tables in review articles were more likely to contain both quantitative and qualitative content. Tables in research articles had a greater number of rows, columns, and column-heading levels than tables in review articles. More than one half of statistical tables in research articles had a separate probability column or had probability values within the table, whereas approximately one fourth had probability notes. Authors and journal editorial staff may be generating tables that better depict biobehavioral content than those identified in specific style guidelines. However, authors and journal editorial staff may want to consider table design in terms of audience, including alternative visual displays.

  14. Electron-Beam-Lithographed Nanostructures as Reference Materials for Label-Free Scattered-Light Biosensing of Single Filoviruses.

    PubMed

    Agrawal, Anant; Majdi, Joseph; Clouse, Kathleen A; Stantchev, Tzanko

    2018-05-23

    Optical biosensors based on scattered-light measurements are being developed for rapid and label-free detection of single virions captured from body fluids. Highly controlled, stable, and non-biohazardous reference materials producing virus-like signals are valuable tools to calibrate, evaluate, and refine the performance of these new optical biosensing methods. To date, spherical polymer nanoparticles have been the only non-biological reference materials employed with scattered-light biosensing techniques. However, pathogens like filoviruses, including the Ebola virus, are far from spherical and their shape strongly affects scattered-light signals. Using electron beam lithography, we fabricated nanostructures resembling individual filamentous virions attached to a biosensing substrate (silicon wafer overlaid with silicon oxide film) and characterized their dimensions with scanning electron and atomic force microscopes. To assess the relevance of these nanostructures, we compared their signals across the visible spectrum to signals recorded from Ebola virus-like particles which exhibit characteristic filamentous morphology. We demonstrate the highly stable nature of our nanostructures and use them to obtain new insights into the relationship between virion dimensions and scattered-light signal.

  15. Preparation and value assignment of standard reference material 968e fat-soluble vitamins, carotenoids, and cholesterol in human serum.

    PubMed

    Thomas, Jeanice B; Duewer, David L; Mugenya, Isaac O; Phinney, Karen W; Sander, Lane C; Sharpless, Katherine E; Sniegoski, Lorna T; Tai, Susan S; Welch, Michael J; Yen, James H

    2012-01-01

    Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.

  16. INAA Application for Trace Element Determination in Biological Reference Material

    NASA Astrophysics Data System (ADS)

    Atmodjo, D. P. D.; Kurniawati, S.; Lestiani, D. D.; Adventini, N.

    2017-06-01

    Trace element determination in biological samples is often used in the study of health and toxicology. Determination change to its essentiality and toxicity of trace element require an accurate determination method, which implies that a good Quality Control (QC) procedure should be performed. In this study, QC for trace element determination in biological samples was applied by analyzing the Standard Reference Material (SRM) Bovine muscle 8414 NIST using Instrumental Neutron Activation Analysis (INAA). Three selected trace element such as Fe, Zn, and Se were determined. Accuracy of the elements showed as %recovery and precision as %coefficient of variance (%CV). The result showed that %recovery of Fe, Zn, and Se were in the range between 99.4-107%, 92.7-103%, and 91.9-112%, respectively, whereas %CV were 2.92, 3.70, and 5.37%, respectively. These results showed that INAA method is precise and accurate for trace element determination in biological matrices.

  17. Eddy-Current Reference Standard

    NASA Technical Reports Server (NTRS)

    Ambrose, H. H., Jr.

    1985-01-01

    Magnetic properties of metallic reference standards duplicated and stabilized for eddy-current coil measurements over long times. Concept uses precisely machined notched samples of known annealed materials as reference standards.

  18. Shaking Table Experiment of Trampoline Effect

    NASA Astrophysics Data System (ADS)

    Aoi, S.; Kunugi, T.; Fujiwara, H.

    2010-12-01

    It has been widely thought that soil response to ground shaking do not experience asymmetry in ground motion. An extreme vertical acceleration near four times gravity was recorded during the 2008 Iwate-Miyagi earthquake at IWTH25 station. This record is distinctly asymmetric in shape; the waveform envelope amplitude is about 1.6 times larger in the upward direction compared to the downward direction. To explain this phenomenon, Aoi et al. (2008) proposed a simple model of a mass bouncing on a trampoline. In this study we perform a shaking table experiment of a soil prototype to try to reproduce the asymmetric ground motion and to investigate the physics of this asymmetric behavior. A soil chamber made of an acrylic resin cylinder with 200 mm in diameter and 500 mm in height was tightly anchored to the shaking table and vertically shaken. We used four different sample materials; Toyoura standard sands, grass beads (particle size of 0.1 and 0.4 mm) and sawdust. Sample was uniformly stacked to a depth of 450 mm and, to measure the vertical motions, accelerometers was installed inside the material (at depths of 50, 220, and 390 mm) and on the frame of the chamber. Pictures were taken from a side by a high speed camera (1000 frames/sec) to capture the motions of particles. The chamber was shaken by sinusoidal wave (5, 10, and 20 Hz) with maximum amplitudes from 0.1 to 4.0 g. When the accelerations roughly exceeded gravity, for all samples, granular behaviors of sample materials became dominant and the asymmetric motions were successfully reproduced. Pictures taken by the high speed camera showed that the motions of the particles are clearly different from the motion of the chamber which is identical to the sinusoidal motion of the shaking table (input motion). Particles are rapidly flung up and freely pulled down by gravity, and the downward motion of the particles is slower than the upward motion. It was also observed that the timing difference of the falling motions

  19. Antarctic ice-core water (USGS49) – A new isotopic reference material for δ2H and δ18O measurements of water

    USGS Publications Warehouse

    Lorenz, Jennifer M.; Qi, Haiping; Coplen, Tyler B.

    2017-01-01

    As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from ice-core water from the Amundsen–Scott South Pole Station. This isotopic reference material, designated as USGS49, was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity and measured by dual-inlet isotope-ratio mass spectrometry. The δ2H and δ18O values of USGS49 are −394.7 ± 0.4 and −50.55 ± 0.04 mUr (where mUr = 0.001 = ‰), respectively, relative to VSMOW, on scales normalised such that the δ2H and δ18O values of SLAP reference water are, respectively, −428 and −55.5 mUr. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material is intended as one of two isotopic reference waters for daily normalisation of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. It is available by the case of 144 glass ampoules or as a set of sixteen glass ampoules containing 5 ml of water in each ampoule.

  20. Rayleigh Scattering in Planetary Atmospheres: Corrected Tables Through Accurate Computation of X and Y Functions

    NASA Astrophysics Data System (ADS)

    Natraj, Vijay; Li, King-Fai; Yung, Yuk L.

    2009-02-01

    Tables that have been used as a reference for nearly 50 years for the intensity and polarization of reflected and transmitted light in Rayleigh scattering atmospheres have been found to be inaccurate, even to four decimal places. We convert the integral equations describing the X and Y functions into a pair of coupled integro-differential equations that can be efficiently solved numerically. Special care has been taken in evaluating Cauchy principal value integrals and their derivatives that appear in the solution of the Rayleigh scattering problem. The new approach gives results accurate to eight decimal places for the entire range of tabulation (optical thicknesses 0.02-1.0, surface reflectances 0-0.8, solar and viewing zenith angles 0°-88.85°, and relative azimuth angles 0°-180°), including the most difficult case of direct transmission in the direction of the sun. Revised tables have been created and stored electronically for easy reference by the planetary science and astrophysics community.