Sample records for tachosil hemostatic pad

  1. Prevention of postoperative pericardial adhesions with TachoSil.

    PubMed

    Kuschel, Tarah J; Gruszka, Anna; Hermanns-Sachweh, Benita; Elyakoubi, Jaouad; Sachweh, Joerg S; Vázquez-Jiménez, Jaime F; Schnoering, Heike

    2013-01-01

    The prevention of the pericardial adhesions largely accountable for the technical difficulty and risk of injury inherent to resternotomy continues to gain in importance with the increasing frequency of reoperations. The hemostatic sponge TachoSil (Nycomed Austria GmbH, Linz, Austria), has shown promising results in adhesion prevention in several regions of the body. This study was designed to evaluate its effectiveness in the prevention of pericardial adhesions in comparison with the Gore-Tex (W. L. Gore and Assoc, Flagstaff, AZ) surgical membrane and a control. Twenty-four rabbits were distributed into 3 groups: TachoSil, Gore-Tex, or no barrier agent (control). After median sternotomy and pericardiotomy, the cardial surface was exposed to the aggravating effects of room air, irrigation, and gauze abrasion for one hour. A pericardial defect was created and repaired with one of the barrier agents, or left uncovered (control). Resternotomy was performed after 6 months for the evaluation of adhesion formation. Significantly fewer macroscopic adhesions were observed with TachoSil than Gore-Tex in all regions (p < 0.05) excluding the coronary arteries, where the difference in favor of TachoSil did not achieve significance (0.05< p-value <0.10). TachoSil also demonstrated significantly fewer retrosternal adhesions than the control, as well as a universal non-significant trend of fewer adhesions in all regions. The limited lesions present in the TachoSil group were filmy in nature and removed with blunt dissection relatively easily. No significant differences were found between Gore-Tex and the control. Microscopically, the least pronounced fibrosis formation and inflammatory reaction was detected with TachoSil. TachoSil is effective in the prevention of pericardial adhesions. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. A randomized, controlled trial of Veriset™ hemostatic patch in halting cardiovascular bleeding.

    PubMed

    Glineur, David; Hendrikx, Marc; Krievins, Dainis; Stradins, Peteris; Voss, Bernhard; Waldow, Thomas; Haenen, Luc; Oberhoffer, Martin; Ritchie, Caroline M

    2018-01-01

    Obtaining hemostasis during cardiovascular procedures can be a challenge, particularly around areas with a complex geometry or that are difficult to access. While several topical hemostats are currently on the market, most have caveats that limit their use in certain clinical scenarios such as pulsatile arterial bleeding. The aim of this study was to assess the effectiveness and safety of Veriset™ hemostatic patch in treating cardiovascular bleeding. Patients (N=90) scheduled for cardiac or vascular surgery at 12 European institutions were randomized 1:1 to treatment with either Veriset™ hemostatic patch (investigational device) or TachoSil ® (control). After application of the hemostat, according to manufacturer instructions for use, time to hemostasis was monitored. Follow-up occurred up to 90 days post-surgery. Median time to hemostasis was 1.5 min with Veriset™ hemostatic patch, compared to 3.0 min with TachoSil ® ( p <0.0001). Serious adverse events within 30 days post-surgery were experienced by 12/44 (27.3%) patients treated with Veriset™ hemostatic patch and 10/45 (22.2%) in the TachoSil ® group ( p =0.6295). None of these adverse events were device-related, and no reoperations for bleeding were required within 5 days post-surgery in either treatment group. This study reinforces the difference in minimum recommended application time between Veriset™ hemostatic patch and TachoSil ® (30 s versus 3 min respectively). When compared directly at 3 min, Veriset™ displayed no significant difference, showing similar hemostasis and safety profiles on the cardiovascular bleeding sites included in this study.

  3. Next Generation Hemostatic Materials Based on NHS-Ester Functionalized Poly(2-oxazoline)s.

    PubMed

    Boerman, Marcel A; Roozen, Edwin; Sánchez-Fernández, María José; Keereweer, Abraham R; Félix Lanao, Rosa P; Bender, Johan C M E; Hoogenboom, Richard; Leeuwenburgh, Sander C; Jansen, John A; Van Goor, Harry; Van Hest, Jan C M

    2017-08-14

    In order to prevent hemorrhage during surgical procedures, a wide range of hemostatic agents have been developed. However, their efficacy is variable; hemostatic devices that use bioactive components to accelerate coagulation are dependent on natural sources, which limits reproducibility. Hybrid devices in which chain-end reactive poly(ethylene glycol) is employed as active component sometimes suffer from irregular cross-linking and dissolution of the polar PEG when blood flow is substantial. Herein, we describe a synthetic, nonbioactive hemostatic product by coating N-hydroxysuccinimide ester (NHS)-functional poly(2-oxazoline)s (POx-NHS) onto gelatin patches, which acts by formation of covalent cross-links between polymer, host blood proteins, gelatin and tissue to seal the wound site and prevent hemorrhage during surgery. We studied different process parameters (including polymer, carrier, and coating technique) in direct comparison with clinical products (Hemopatch and Tachosil) to obtain deeper understanding of this class of hemostatic products. In this work, we successfully prove the hemostatic efficacy of POx-NHS as polymer powders and coated patches both in vitro and in vivo against Hemopatch and Tachosil, demonstrating that POx-NHS are excellent candidate polymers for the development of next generation hemostatic patches.

  4. The hemostatic efficacy of chitosan-pads in hemodialysis patients with significant bleeding tendency.

    PubMed

    Misgav, Mudi; Lubetszki, Ahron; Brutman-Barazani, Tami; Martinowitz, Uri; Kenet, Gili

    2017-05-15

    Patients on chronic hemodialysis often have acquired coagulopathy that can aggravate bleeding from puncture site after needle extraction. Chitosan-based pads have been reported to accelerate hemostasis even in the presence of coagulopathy. The aim of this study was to evaluate the hemostatic efficacy of the chitosan pads compared to gauze pads, applied for local hemostasis. A crossover study in a cohort of patients on hemodialysis with extended time to hemostasis after needle extraction. At the end of each dialysis, either gauze or chitosan pad was applied on both access points (arterial and venous). The type of pad was changed in the next dialysis all together 5 times in each patient (10 applications per patient for every pad). A total of 288 applications, 144 for each type of pad, were performed in 15 patients. The average time to hemostasis for the entire group was significantly shorter with the chitosan pads compared to the regular gauze pads ("arterial" point 3 vs. 18.5 min, p<0.001 "venous" access 2.8 vs. 13.2 min, p<0.001, respectively). Chitosan pads significantly reduce time to hemostasis and should be considered for the treatment of accessible bleeds in patients with coagulopathy.

  5. Safety and hemostatic efficacy of fibrin pad in partial nephrectomy: Results of an open-label Phase I and a randomized, standard-of-care-controlled Phase I/II study

    PubMed Central

    2012-01-01

    Background Bleeding severity, anatomic location, tissue characteristics, and visibility are common challenges encountered while managing intraoperative bleeding, and conventional hemostatic measures (suture, ligature, and cautery) may sometimes be ineffective or impractical. While topical absorbable hemostats (TAH) are useful hemostatic adjuvants, each TAH has associated disadvantages. Methods We evaluated the safety and hemostatic efficacy of a new advanced biologic combination product―fibrin pad―to potentially address some gaps associated with TAHs. Fibrin pad was assessed as adjunctive hemostat in open partial nephrectomy in single-center, open-label, Phase I study (N = 10), and as primary hemostat in multicenter, single-blind, randomized, standard-of-care (SOC)-controlled Phase I/II study (N = 7) in Israel. It was used to control mild-to-moderate bleeding in Phase I and also spurting arterial bleeding in Phase I/II study. Phase I study assessed safety and Phase I/II study, proportion of successes at 10 min following randomization, analyzed by Fisher exact tests at 5% significance level. Results Phase I (N = 10): All patients completed the study. Hemostasis was achieved within 3–4 min (average = 3.1 min) of a single application in all patients. Fibrin pad was found to be safe for human use, with no product-related adverse events reported. Phase I/II (N = 7): Hemostatic success at 10 min (primary endpoint) was achieved in 3/4 patients treated with fibrin pad versus 0/3 patients treated with SOC. No clinically significant change in laboratory or coagulation parameters was recorded, except a case of post-procedural hemorrhage with fibrin pad, which was considered serious and related to the fibrin pad treatment, and required re-operation. Although Data Safety Monitoring Board authorized trial continuation, the sponsor decided against proceeding toward an indication for primary treatment of severe arterial hemorrhage as a replacement

  6. Usefulness of hemostatic sealants for minimizing ovarian damage during laparoscopic cystectomy for endometriosis.

    PubMed

    Choi, Chahien; Kim, Woo Young; Lee, Dong Hee; Lee, San Hui

    2018-03-01

    We aimed to evaluate the impact of topical hemostatic sealants and bipolar coagulation during laparoscopic ovarian endometriotic cyst resection on ovarian reserve by comparing the rates of decrease in anti-Müllerian hormone (AMH). A randomized prospective data collection was made on women aged 19-45 years who planned to have laparoscopic ovarian cystectomy at one of two institutions (n = 80), Kangbuk Samsung Hospital, Seoul, Korea or National Health Insurance Service Ilsan Hospital, Goyang, Korea, from January 2014 to April 2016. Patients were randomly divided into two groups treated with either a topical hemostatic sealant or bipolar coagulation for hemostasis. The hemostatic group was randomized to the FloSeal or TachoSil subgroups. Preoperative and 3-month postoperative AMH levels were checked and the rates of decrease of AMH were compared. All patients enrolled were treated with dienogest (Visanne) for 6-12 months. None were lost to follow-up at postoperative 3 months, but about one-third of the patients had been lost to follow-up by 6-12 months. AMH was significantly decreased in both groups 3 months postoperatively; however, the rate of decrease in the bipolar coagulation group was greater than that in the hemostatic sealant group, 41.9% (interquartile range [IQR], 22.29-65.24) versus 18.1% (IQR, 10.94-29.90), P = 0.007. Between the two hemostatic subgroups, there was no significant difference in AMH decrease rate, 14.95% (IQR, 11.34-21.21) versus 18.1% (IQR 9.76-40.70), P = 0.204. Hemostatic sealants may be an alternative to bipolar coagulation for preservation of ovarian reserve after laparoscopic ovarian cystectomy for endometriosis. © 2017 Japan Society of Obstetrics and Gynecology.

  7. [Topical hemostatic devices in surgery: between science and marketing].

    PubMed

    González, Héctor Daniel; Figueras Felip, Joan

    2009-06-01

    Topical hemostatic agents have been used in surgery with varying degrees of success. These agents include oxidized cellulose, absorbable gelatin sponges, microfibrillar collagen and fibrin seals. Fibrin seals have become widely used as they improve perioperative hemostasis, reduce the need for red blood cell transfusions and prevent biliary leaks. Their widespread use, however, contrasts with the scarcity of data from controlled studies to support their clinical effectiveness. Therefore, a prospective, randomized, controlled, single-center study was performed in 300 patients who underwent elective hepatectomy, with and without application of fibrin seal on the raw liver surface. None of the variables evaluated (blood loss, transfusions, biliary fistulas and postoperative results) differed between the two groups. We conclude that the application of fibrin seal does not seem justified and that discontinuing its routine use would substantially reduce costs. The use of a new agent, Tachosil, is supported by a single multicenter, prospective, randomized, controlled trial, which is limited by the small number of patients and by the fact that the variable analyzed--time from application to hemostasis--may not be clinically relevant.

  8. Hemostatic strategies for traumatic and surgical bleeding

    PubMed Central

    Behrens, Adam M.; Sikorski, Michael J.; Kofinas, Peter

    2017-01-01

    Wide interest in new hemostatic approaches has stemmed from unmet needs in the hospital and on the battlefield. Many current commercial hemostatic agents fail to fulfill the design requirements of safety, efficacy, cost, and storage. Academic focus has led to the improvement of existing strategies as well as new developments. This review will identify and discuss the three major classes of hemostatic approaches: biologically derived materials, synthetically derived materials, and intravenously administered hemostatic agents. The general class is first discussed, then specific approaches discussed in detail, including the hemostatic mechanisms and the advancement of the method. As hemostatic strategies evolve and synthetic-biologic interactions are more fully understood, current clinical methodologies will be replaced. PMID:24307256

  9. Economic and outcomes consequences of TachoSil®: a systematic review.

    PubMed

    Colombo, Giorgio L; Bettoni, Daria; Di Matteo, Sergio; Grumi, Camilla; Molon, Cinzia; Spinelli, Daniela; Mauro, Gaetano; Tarozzo, Alessia; Bruno, Giacomo M

    2014-01-01

    TachoSil(®) is a medicated sponge coated with human fibrinogen and human thrombin. It is indicated as a support treatment in adult surgery to improve hemostasis, promote tissue sealing, and support sutures when standard surgical techniques are insufficient. This review systematically analyses the international scientific literature relating to the use of TachoSil in hemostasis and as a surgical sealant, from the point of view of its economic impact. We carried out a systematic review of the PubMed literature up to November 2013. Based on the selection criteria, papers were grouped according to the following outcomes: reduction of time to hemostasis; decrease in length of hospital stay; and decrease in postoperative complications. Twenty-four scientific papers were screened, 13 (54%) of which were randomized controlled trials and included a total of 2,116 patients, 1,055 of whom were treated with TachoSil. In the clinical studies carried out in patients undergoing hepatic, cardiac, or renal surgery, the time to hemostasis obtained with TachoSil was lower (1-4 minutes) than the time measured with other techniques and hemostatic drugs, with statistically significant differences. Moreover, in 13 of 15 studies, TachoSil showed a statistically significant reduction in postoperative complications in comparison with the standard surgical procedure. The range of the observed decrease in the length of hospital stay for TachoSil patients was 2.01-3.58 days versus standard techniques, with a statistically significant difference in favor of TachoSil in eight of 15 studies. This analysis shows that TachoSil has a role as a supportive treatment in surgery to improve hemostasis and promote tissue sealing when standard techniques are insufficient, with a consequent decrease in postoperative complications and hospital costs.

  10. Evolution of hemostatic agents in surgical practice

    PubMed Central

    Sundaram, Chandru P.; Keenan, Alison C.

    2010-01-01

    Objective: Topical hemostatic agents are used in a wide variety of surgical settings, and the evolution of this class of surgical tools is an interesting topic. We reviewed and outlined the historical progress of topical hemostats into present day surgery and urology, and highlight opportunities for future research. Materials and Methods: A MEDLINE search of all available literature concerning several classes of topical hemostatic agents was performed. Fibrins sealants, Gelatin sponge hemostatics, cyanoacrylate adhesives, oxidized regenerated cellulose, and microfibrillar collagen were included. References were chosen from a broad range of surgical literature. Results: Topical hemostatic agents have historically taken advantage of a wide variety of mechanisms for hemostasis. Fibrin sealants have a rich history and large potential for further applications. Gelatin sponge hemostatics have been widely used since their introduction, but have changed little. Cyanoacrylate adhesives have a unique mechanism and opportunity for novel applications of existing products. Oxidized cellulose was original in the use of plant-based components. Microfibrillar collagen hemostats have evolved to a wide variety of formats. Conclusions: A review of the evolution of topical hemostatic agents highlights opportunities for potential novel research. Fibrin sealants may have the most opportunity for advancement, and understanding the history of these products is useful. With the drive in urology for minimally invasive surgical techniques, adaptation of topical hemostatic agents to this surgical approach would be valuable and offers an opportunity for novel contributions. PMID:21116358

  11. Efficacy of hemostatic matrix and microporous polysaccharide hemospheres.

    PubMed

    Lewis, Kevin M; Atlee, Holly; Mannone, Angela; Lin, Lawrence; Goppelt, Andreas

    2015-02-01

    Microporous Polysaccharide Hemospheres (MPH) are a new plant-derived polysaccharide powder hemostat. Previous studies investigated MPH as a replacement to nonflowable hemostatic agents of different application techniques (e.g., oxidized cellulose, collagen); therefore, the purpose of this study was to determine if MPH is a surrogate for flowable hemostatic agents of similar handling and application techniques, specifically a flowable thrombin-gelatin hemostatic matrix. Hemostatic efficacy was compared using a heparinized porcine abrasion model mimicking a capsular tear of a parenchymal organ. MPH (ARISTA, 1 g) and hemostatic matrix (Floseal, 1 mL) were applied, according to a randomized scheme, to paired hepatic abrasions (40 lesions per group). Hemostatic success, control of bleeding, and blood loss were assessed 2, 5, and 10 min after treatment. Hemostatic success and control of bleeding were analyzed using odds ratios and blood loss using mean differences. Hemostatic matrix provided superior hemostatic success relative to MPH at 5 (odds ratio: 0.035, 95% confidence interval: 0.004-0.278) and 10 min (0.032, 0.007-0.150), provided superior control of bleeding at 5 (0.006, <0.001-0.037) and 10 min (0.009, 0.001-0.051), and had significantly less blood loss at 5 (mean difference: 0.3118 mL/min, 95% confidence interval: 0.0939-0.5296) and 10 min (0.5025, 0.2489-0.7561). These findings corroborate other MPH investigations regarding its low-level efficacy and suggest that MPH is not an appropriate surrogate for hemostatic matrix despite similar application techniques. The lack of a procoagulant within MPH may likely be the reason for its lower efficacy and need for multiple applications. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  12. New hemostatic agents in the combat setting.

    PubMed

    Cox, E Darrin; Schreiber, Martin A; McManus, John; Wade, Charles E; Holcomb, John B

    2009-12-01

    Hemorrhage is a leading cause of potentially preventable death in both civilian and military trauma patients. Animal data have shown that hemostatic bandages reduce hemorrhage and improve survival. This article reports recent clinical observations regarding the efficacy and evolution of use of two new hemostatic bandages employed in the global war on terrorism. We performed a retrospective cohort review of soldiers treated with either the QuikClot or HemCon hemostatic bandages between April and October 2006. Hemostatic dressings were placed on wounds either in the field or at the combat support hospital (CSH). During the 6-month study period, 1691 trauma patients were admitted to the CSH. Fifty uses of hemostatic dressings in 44 patients (2.6% of admissions) were identified. Forty patients were treated with HemCon dressings, three patients with QuikClot, and one with both QuikClot and HemCon. Eighteen percent of the dressings were used in the field, predominantly on extremity wounds (7/8). In contrast, most dressings used in the CSH were for truncal wounds (26/36 patients). Hemostatic dressings were applied to extremity wounds in prehospital and hospital settings, either alone or in conjunction with tourniquets. In surviving patients (95%), the treating surgeon determined that the hemorrhage was either stopped or greatly decreased by use of hemostatic dressings. Two of the four patients treated with QuikClot had burns from exothermic reactions, while no adverse reactions were noted with HemCon. Hemostatic agents stop or decrease bleeding. Whereas HemCon appears to be safe, QuikClot may produce superficial burns. These new hemostatic agents have a place in the surgical armamentarium to assist in controlling internal hemorrhage from truncal and pelvic hemorrhage, especially during damage-control surgery.

  13. Hemostatic efficacy of EVARREST™, Fibrin Sealant Patch vs. TachoSil® in a heparinized swine spleen incision model.

    PubMed

    Matonick, John P; Hammond, Jeffrey

    2014-12-01

    First-generation single-component hemostats such as oxidized regenerated cellulose (ORC), fibrin, collagen, and gelatin have evolved into second and third generations of combination hemostats. This study compares two FDA approved products, EVARREST™, Fibrin Sealant Patch, a hemostat comprised of a matrix of nonwoven polyglactin 910 embedded in ORC coated with human fibrinogen and thrombin to TachoSil® medicated sponge, an equine collagen pad coated with human fibrinogen and thrombin. Swine were anticoagulated with heparin to 3X their baseline activated clotting time and a 15 mm long × 3 mm deep incision was made to create a consistent moderate bleeding pattern. Test material was then applied to the wound site and compressed manually for 3 min with just enough pressure to prevent continued bleeding. Hemostatic effectiveness was evaluated at 3 min and 10 min. At 3 min, the hemostasis success rate was 86% in the EVARREST™ group and 0% in the TachoSil® group, p < .0001. The overall success rate at 10 min was 100% with EVARREST™ and 4% with TachoSil®, p < .0001. Adhesive failure, in which the test material did not stick to the tissue, occurred in 96% of TachoSil® sites. In contrast, 100% of the EVARREST™ applications adhered to the test site. EVARREST™, Fibrin Sealant Patch demonstrated greater wound adhesion and more effective hemostasis than TachoSil®. Adhesive failure was the primary failure mode for TachoSil® in this model.

  14. Synthetic Strategies for Engineering Intravenous Hemostats

    PubMed Central

    Chan, Leslie W.-G.; White, Nathan J.; Pun, Suzie H.

    2015-01-01

    While there are currently many well-established topical hemostatic agents for field administration, there are still limited tools to staunch bleeding at less accessible injury sites. Current clinical methods of restoring hemostasis after large volume blood loss include platelet and clotting factor transfusion, which have respective drawbacks of short shelf-life and risk of viral transmission. Therefore, synthetic hemostatic agents that can be delivered intravenously and encourage stable clot formation after localizing to sites of vascular injury are particularly appealing. In the past three decades, platelet substitutes have been prepared using drug delivery vehicles such as liposomes and PLGA nanoparticles that have been modified to mimic platelet properties. Additionally, structural considerations such as particle size, shape, and flexibility have been addressed in a number of reports. Since platelets are the first responders after vascular injury, platelet substitutes represent an important class of intravenous hemostats under development. More recently, materials affecting fibrin formation have been introduced to induce faster or more stable blood clot formation through fibrin crosslinking. Fibrin represents a major structural component in the final blood clot, and a fibrin-based hemostatic mechanism acting downstream of initial platelet plug formation may be a safer alternative to platelets to avoid undesired thrombotic activity. This review explores intravenous hemostats under development and strategies to optimize their clotting activity. PMID:25803791

  15. Tensile strength of biological fibrin sealants: a comparative study.

    PubMed

    Lacaze, Laurence; Le Dem, Nicolas; Bubenheim, Michael; Tsilividis, Basile; Mezghani, Julien; Schwartz, Lilian; Francois, Arnaud; Ertaud, Jean Yves; Bagot d'Arc, Maurice; Scotté, Michel

    2012-08-01

    Fibrin sealants are commonly used in liver surgery, although their effectiveness in routine clinical practice remains controversial. Individual sealant characteristics are based on hemostatic effects and adhesion properties that can be experimentally measured using the 'rat skin test' or the 'pig skin test'. This study used a more relevant and realistic experimental canine model to compare the differences in the adhesive properties of four fibrin sealants in hepatectomy: Tisseel/Tissucol, Tachosil, Quixil, and Beriplast. A partial hepatectomy was performed in beagle dogs under general anesthesia to obtain liver cross-sections. Fibrin sealants were allocated to dog livers using a Youden square design. The tensile strength measurement was performed using a traction system to measure the rupture stress point of a small wooden cylinder bonded to the liver cross-section. Significantly greater adhesion properties were observed with Tisseel/Tissucol compared with Quixil or Beriplast (P = 0.002 and 0.001, respectively). Similarly, Tachosil demonstrated significantly greater adhesive properties compared with Beriplast (P = 0.009) or Quixil (P = 0.014). No significant differences were observed between Tisseel/Tissucol and Tachosil or between Beriplast and Quixil. The results of this comparative study demonstrate that different fibrin sealants exhibit different adhesive properties. Tisseel/Tissucol and Tachosil provided greatest adhesion to liver cross-section in our canine model of hepatectomy. These results may enable the optimal choice of fibrin sealants for this procedure in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Ankaferd hemostat in the management of gastrointestinal hemorrhages

    PubMed Central

    Beyazit, Yavuz; Kekilli, Murat; Haznedaroglu, Ibrahim C; Kayacetin, Ertugrul; Basaranoglu, Metin

    2011-01-01

    Gastrointestinal (GI) bleeding refers to any hemorrhage ascribed to the pathologies of the gastrointestinal tract, extending from the mouth to the anal canal. Despite the recent improvements in the endoscopic, hemostatic and adjuvant pharmacologic techniques, the reported mortality is still around 5%-10% for peptic ulcer bleeding and about 15%-20% for variceal hemorrhages. Although endoscopic management reduces the rates of re-bleeding, surgery, and mortality in active bleeding; early recurrence ratios still occur in around 20% of the cases even with effective initial hemostatic measures. In this quest for an alternative pro-hemostatic agent for the management of GI bleedings, Ankaferd blood stopper (ABS) offers a successful candidate, specifically for “difficult-to-manage” situations as evidenced by data presented in several studies. ABS is a standardized mixture of the plants Thymus vulgaris, Glycyrrhiza glabra, Vitis vinifera, Alpinia officinarum, and Urtica dioica. It is effective in both bleeding individuals with normal hemostatic parameters and in patients with deficient primary and/or secondary hemostasis. ABS also modulates the cellular apoptotic responses to hemorrhagic stress, as well as hemostatic hemodynamic activity. Through its effects on the endothelium, blood cells, angiogenesis, cellular proliferation, vascular dynamics, and wound healing, ABS is now becoming an effective alternative hemostatic medicine for gastrointestinal bleedings that are resistant to conventional anti-hemorrhagic measurements. The aim of this review is to outline current literature experience suggesting the place of ABS in the management of GI bleeding, and potential future controlled trials in this complicated field. PMID:22046083

  17. Embolization with ethylene vinyl alcohol copolymer (Onyx®) for peripheral hemostatic and non-hemostatic applications: a feasibility and safety study

    PubMed Central

    Né, Romaric; Chevallier, Olivier; Falvo, Nicolas; Facy, Olivier; Berthod, Pierre-Emmanuel; Galland, Christophe; Gehin, Sophie; Midulla, Marco

    2018-01-01

    Background Onyx® is a liquid embolic agent, which is approved for the treatment of cerebral vascular lesions but still rarely used in peripheral interventional radiology. The goal of this study is to report the feasibility and safety of embolization with Onyx® for peripheral hemostatic and non-hemostatic endovascular procedures. Methods Retrospective study of all consecutive patients who underwent visceral or peripheral embolization with Onyx® for hemostatic or non-hemostatic purpose in our department between May 2014 and November 2016. Demographic data, clinical presentation, underlying etiology, culprit vessel, endovascular procedure, pain during embolization, outcomes, and follow-up data were collected. Results Fifty patients (males, 34; females, 16; mean age, 56±18 years; range, 15–89 years) were included. Twenty-nine (58%) of patients underwent hemostatic embolization for arterial (n=22, 44%) or venous (n=7, 14%) bleeding lesions, whereas 21 (42%) of patients underwent non-hemostatic embolization for arterial aneurysms (n=8, 16%), preoperative portal vein deprivation (n=6, 12%) or other indications (n=7, 14%). Onyx-18 was used in 37 (74%) patients, Onyx-34 in 9 (18%) patients, and a combination of both in 4 (8%) patients. Onyx was used alone in 25 (50%) patients and in combination with other agent in 25 (50%) patients. Mean number of Onyx® vials used was 3.7 (range, 1–17). Immediate technical success rate was 100%. Primary clinical success was achieved in all patients. Recurrent bleeding occurred in two patients. Significant pain (pain score ≥3) was noted during injection in 10 (20%) patients. No major complication or side effects were noted within 1 month. Conclusions Transcatheter embolization with Onyx® is feasible and safe in the peripheral arterial or venous vasculature for both bleeding and non-bleeding patients whatever the anatomic site. PMID:29774181

  18. Embolization with ethylene vinyl alcohol copolymer (Onyx®) for peripheral hemostatic and non-hemostatic applications: a feasibility and safety study.

    PubMed

    Né, Romaric; Chevallier, Olivier; Falvo, Nicolas; Facy, Olivier; Berthod, Pierre-Emmanuel; Galland, Christophe; Gehin, Sophie; Midulla, Marco; Loffroy, Romaric

    2018-04-01

    Onyx ® is a liquid embolic agent, which is approved for the treatment of cerebral vascular lesions but still rarely used in peripheral interventional radiology. The goal of this study is to report the feasibility and safety of embolization with Onyx ® for peripheral hemostatic and non-hemostatic endovascular procedures. Retrospective study of all consecutive patients who underwent visceral or peripheral embolization with Onyx ® for hemostatic or non-hemostatic purpose in our department between May 2014 and November 2016. Demographic data, clinical presentation, underlying etiology, culprit vessel, endovascular procedure, pain during embolization, outcomes, and follow-up data were collected. Fifty patients (males, 34; females, 16; mean age, 56±18 years; range, 15-89 years) were included. Twenty-nine (58%) of patients underwent hemostatic embolization for arterial (n=22, 44%) or venous (n=7, 14%) bleeding lesions, whereas 21 (42%) of patients underwent non-hemostatic embolization for arterial aneurysms (n=8, 16%), preoperative portal vein deprivation (n=6, 12%) or other indications (n=7, 14%). Onyx-18 was used in 37 (74%) patients, Onyx-34 in 9 (18%) patients, and a combination of both in 4 (8%) patients. Onyx was used alone in 25 (50%) patients and in combination with other agent in 25 (50%) patients. Mean number of Onyx ® vials used was 3.7 (range, 1-17). Immediate technical success rate was 100%. Primary clinical success was achieved in all patients. Recurrent bleeding occurred in two patients. Significant pain (pain score ≥3) was noted during injection in 10 (20%) patients. No major complication or side effects were noted within 1 month. Transcatheter embolization with Onyx ® is feasible and safe in the peripheral arterial or venous vasculature for both bleeding and non-bleeding patients whatever the anatomic site.

  19. The TachoSil-Pledget stitch: towards eradication of suture hole bleeding.

    PubMed

    Shimamoto, Takeshi; Marui, Akira; Nishina, Takeshi; Saji, Yoshiaki; Komeda, Masashi

    2008-12-01

    We describe a novel suture consisting of a small piece of TachoSil (Nycomed, Copenhagen, Denmark) and a felt pledget-the TachoSil-pledget stitch-which was used to facilitate mechanical and biologic hemostasis in 5 patients undergoing aortic arch aneurysm repair. The TachoSil-pledget stitch achieved good or very good hemostasis at all 56 bleeding points to which it was applied, while 5 of 12 points to which a conventional felt-pledget stitch was applied required additional stitching or an additional hemostatic method.

  20. Effect of carprofen on hemostatic variables in dogs.

    PubMed

    Hickford, F H; Barr, S C; Erb, H N

    2001-10-01

    To evaluate the effect of carprofen on hemostatic variables in clinically normal dogs. 12 clinically normal Labrador Retrievers. 10 dogs (6 females, 4 males) received carprofen (2.2 mg/kg of body weight, PO, q 12 h) for 5 days. Two dogs (untreated control group; 1 female, 1 male) did not receive carprofen. Hemostatic variables (platelet count, activated partial thromboplastin time, prothrombin time, fibrinogen, platelet aggregation, and bleeding time) were assessed for all dogs prior to treatment, on day 5 of treatment, and 2 and 7 days after discontinuation of the drug (days 7 and 12). Serum biochemical variables and Hct were assessed prior to treatment and on days 5 and 12. In dogs receiving carprofen, platelet aggregation was significantly decreased, and onset of aggregation was significantly delayed on days 5, 7, and 12, compared with pretreatment values. Activated partial thromboplastin time was significantly increased on days 5, 7, and 12 over pretreatment values in treated dogs, but values remained within reference ranges. Significant differences were not detected in buccal mucosal bleeding time, other serum biochemical and hemostatic variables, or Hct, compared with pretreatment values and the internal control group. Administration of carprofen for 5 days causes minor but not clinically important alterations in hemostatic and serum biochemical variables in clinically normal Labrador Retrievers. Carprofen is commonly used to treat osteoarthritis and chronic pain in dogs, but prior to this study, its effect on platelet aggregation and hemostatic variables was unknown.

  1. In vitro analysis of polyurethane foam as a topical hemostatic agent.

    PubMed

    Broekema, Ferdinand I; van Oeveren, Wim; Zuidema, Johan; Visscher, Susan H; Bos, Rudolf R M

    2011-04-01

    Topical hemostatic agents can be used to treat problematic bleedings in patients who undergo surgery. Widely used are the collagen- and gelatin-based hemostats. This study aimed to develop a fully synthetic, biodegradable hemostatic agent to avoid exposure to animal antigens. In this in vitro study the suitability of different newly developed polyurethane-based foams as a hemostatic agent has been evaluated and compared to commonly used agents. An experimental in vitro test model was used in which human blood flowed through the test material. Different modified polyurethane foams were compared to collagen and gelatin. The best coagulation was achieved with collagen. The results of the polyurethane foam improved significantly by increasing the amount of polyethylene glycol. Therefore, the increase of the PEG concentration seems a promising approach. Additional in vivo studies will have to be implemented to assess the application of polyurethane foam as a topical hemostatic agent.

  2. Comparison of hemostatic matrix and standard hemostasis in patients undergoing primary TKA.

    PubMed

    Comadoll, James L; Comadoll, Shea; Hutchcraft, Audrey; Krishnan, Sangeeta; Farrell, Kelly; Kreuwel, Huub T C; Bechter, Mark

    2012-06-01

    Bleeding after total knee arthroplasty increases the risk of pain, delayed rehabilitation, blood transfusion, and transfusion-associated complications. The authors compared pre- and postoperative decreases in hemoglobin as a surrogate for blood loss in consecutive patients treated at a single institution by the same surgeon (J.L.C.) using conventional hemostatic methods (electrocautery, suturing, or manual compression) or a gelatin and thrombin-based hemostatic matrix during total knee arthroplasty. Data were collected retrospectively by chart review. The population comprised 165 controls and 184 patients treated with hemostatic matrix. Median age was 66 years (range, 28-89 years); 66% were women. The arithmetic mean ± SD for the maximal postoperative decrease in hemoglobin was 3.18 ± 0.94 g/dL for controls and 2.19 ± 0.83 g/dL for the hemostatic matrix group. Least squares means estimates of the group difference (controls-hemostatic matrix) in the maximal decrease in hemoglobin was 0.96 g/dL (95% confidence interval, 0.77-1.14 mg/dL; P<.0001). Statistically significant covariate effects were observed for preoperative hemoglobin level (P<.0001) and body mass index (P=.0029). Transfusions were infrequent in both groups. The frequency of acceptable range of motion was high (control, 88%; hemostatic matrix, 84%). In both groups, overall mean tourniquet time was approximately 1 hour, and the most common length of stay was 3 to 5 days. No serious complications related to the hemostatic agent were observed. These data demonstrate that the use of a flowable hemostatic matrix results in less reduction in hemoglobin than the use of conventional hemostatic methods in patient undergoing total knee arthroplasty. Copyright 2012, SLACK Incorporated.

  3. Comparative evaluation of absorbable hemostats: advantages of fibrin-based sheets.

    PubMed

    Krishnan, Lissy K; Mohanty, Mira; Umashankar, P R; Lal, Arthur Vijayan

    2004-11-01

    Bioactive hemostats and wound dressings consist of either inherently active materials or act as delivery vehicles which contain such materials. Fibrin is a natural hemostat and scaffold, guiding the direction of wound contraction and closure. In order to improve the ease of application of liquid fibrin glue, we have made a freeze-dried form of polymerized fibrin that supports hemostasis and wound healing. The bleeding from the middle ear artery of rabbits was found to be arrested instantaneously on application of fibrin sheets, even when the animal was heparinized systemically. As the fibrin sheet was found to be fragile, gelatin was incorporated to the sheet and thus the mechanical stability was improved without compromising the hemostatic effect. The efficacy of the fabricated fibrin and fibrin-gelatin sheets to seal traumatized rat liver was compared with commercially available hemostats, Abgel (cross-linked gelatin) and Surgicel (cross-linked cellulose). Tissue compatibility of all the hemostats was studied by analyzing the liver tissue 15 days after application. While the hemostatic effect was best with fibrin and fibrin-gelatin sheets, both Surgicel and Abgel were not capable of arresting the bleeding quickly. Gross analysis of tissue on the 15th day of application, visibly, Abgel was not only degraded but resulted in severe adhesions of internal organs and histologically capsule formation around the implant was evident. Though Surgicel was also seen as cream soft material on the site of application that joined two pieces of liver, there was no adhesion of other internal organs and histologically, immune reaction and foreign-body-type giant cells were present in large amounts. Fibrin was not found grossly on application site whereas fibrin-gelatin was seen as a small white spot. Granulation tissue formation and cell migration into the fibrin-based sheets were evident, and therefore, fibrin-based sheets are not only efficient hemostats but showed optimum

  4. Hemostatic abnormalities in dogs with naturally occurring heatstroke.

    PubMed

    Bruchim, Yaron; Kelmer, Efrat; Cohen, Adar; Codner, Carolina; Segev, Gilad; Aroch, Itamar

    2017-05-01

    To investigate hemostatic analyte abnormalities and their association with mortality in dogs with naturally occurring heatstroke. Prospective observational study. University teaching hospital. Thirty client-owned dogs with naturally occurring heatstroke. None. Citrated and EDTA blood samples were collected at presentation and at 4, 12, 24, 36, and 48 hours postpresentation (PP). Hemostatic tests performed included platelet count, prothrombin and activated partial thromboplastin times (PT and aPTT, respectively), antithrombin activity (ATA), total protein C activity (tPCA), fibrinogen, and D-dimer concentrations. The overall survival rate was 60% (18/30 dogs). Older age, higher heart rate and rectal temperature at presentation, and time from onset of clinical signs to presentation were significantly associated with mortality. Hemostatic analytes at presentation were not associated with mortality. Prolonged PT and aPTT at 12-24 hours PP, lower tPCA at 12 hours PP, and hypofibrinogenemia at 24 hours PP were significantly (P < 0.05) associated with mortality. Increased D-dimer concentration and low ATA were common at all time points, but were not associated with mortality. The frequency of disseminated intravascular coagulation (DIC) increased in nonsurvivors throughout hospitalization, but the development of DIC was not associated with mortality. The number of abnormal coagulation disturbances during the first 24 hours was significantly higher in nonsurvivors (P = 0.04). Hemostatic derangements are common in dogs with naturally occurring heatstroke. Alterations in PT, aPTT, tPCA, and fibrinogen concentrations appear to be associated with the outcome at 12-24 hours PP, exemplifying the need for serial measurement of multiple laboratory hemostatic tests during hospitalization, even when within reference interval on presentation. The development of DIC, as defined in this cohort, was not associated with mortality; however, nonsurvivors had significantly more coagulation

  5. Safety biocompatibility of gelatin hemostatic matrix (Floseal and Surgiflo) in neurosurgical procedures.

    PubMed

    Gazzeri, Roberto; Galarza, Marcelo; Alfier, Alex

    2012-12-01

    Adequate hemostasis in cranial and spinal surgery is of paramount importance in a neurosurgeon's daily practice. Generalized ooze bleeding from the surgical wall cavities, coming from the dura mater or nervous tissue may be troublesome and may limit visualization in minimally invasive neurosurgery. Hemostatic matrix is a mixture of a flowable gelatin matrix (bovine or porcine) and a thrombin component mixed together. A total of 318 patients undergoing cranial, craniospinal, and spinal procedure with the use of gelatin hemostatic matrix (Floseal and Surgiflo) were enrolled in this clinical study. We compared the different hemostatic techniques using the gelatin hemostatic matrix, and investigated indications, time to bleeding control, and its efficacy and safety in neurosurgery.

  6. Highly Absorbent Antibacterial Hemostatic Dressing for Healing Severe Hemorrhagic Wounds

    PubMed Central

    Li, Ting-Ting; Lou, Ching-Wen; Chen, An-Pang; Lee, Mong-Chuan; Ho, Tsing-Fen; Chen, Yueh-Sheng; Lin, Jia-Horng

    2016-01-01

    To accelerate healing of severe hemorrhagic wounds, a novel highly absorbent hemostatic dressing composed of a Tencel®/absorbent-cotton/polylactic acid nonwoven base and chitosan/nanosilver antibacterial agent was fabricated by using a nonwoven processing technique and a freeze-drying technique. This study is the first to investigate the wicking and water-absorbing properties of a nonwoven base by measuring the vertical wicking height and water absorption ratio. Moreover, blood agglutination and hemostatic second tests were conducted to evaluate the hemostatic performance of the resultant wound dressing. The blending ratio of fibers, areal weight, punching density, and fiber orientation, all significantly influenced the vertical moisture wicking property. However, only the first two parameters markedly affected the water absorption ratio. After the nonwoven base absorbed blood, scanning electron microscope (SEM) observation showed that erythrocytes were trapped between the fibrin/clot network and nonwoven fibers when coagulation pathways were activated. Prothrombin time (PT) and activated partial thromboplastin time (APTT) blood agglutination of the resultant dressing decreased to 14.34 and 50.94 s, respectively. In the femoral artery of the rate bleeding model, hemostatic time was saved by 87.2% compared with that of cotton cloth. Therefore, the resultant antibacterial wound dressing demonstrated greater water and blood absorption, as well as hemostatic performance, than the commercially available cotton cloth, especially for healing severe hemorrhagic wounds. PMID:28773912

  7. In vivo hemostatic efficacy of polyurethane foam compared to collagen and gelatin.

    PubMed

    Broekema, Ferdinand I; van Oeveren, Wim; Selten, Maaike H A; Meijer, Rolf J H; de Wolf, Joost T M; Bos, Rudolf R M

    2013-05-01

    Topical hemostatic agents are used in all surgical disciplines. Most of these hemostats are based on animal-derived products like collagen and gelatin. They carry the potential risk of pathogen transmission. A newly developed biodegradable, fully synthetic hemostatic agent based on polyurethane foam (PU) with 55 % polyethylene glycol (PEG) would prevent these potential risks. The hemostatic efficacy of this new agent was compared to gelatin and collagen in humans who underwent extraction of an upper and lower molar (split-mouth model). After extraction of a molar in the maxilla and mandible, a PU foam and collagen or gelatin were inserted in the extraction socket for 2 min. Hereafter, the agents were removed and stored in ethylenediaminetetraacetic acid to stop coagulation. Then, the concentration of coagulation parameters thrombin-antithrombin III (TAT) complexes, fibrinogen, and thromboxane B2 (TxB2) in blood extracts from the agents was measured. The concentrations were also determined in baseline blood samples which were collected from the extraction socket. The concentrations of TAT and TxB2 were significantly increased, and fibrinogen concentration was significantly reduced compared to baseline wound blood concentrations indicating enhanced hemostasis. No significant differences were seen in the concentrations of these coagulation parameters in the three different hemostatic agents. These results show that PU combined with 55 % PEG is a promising alternative for the animal-derived hemostatic agents. The synthetic hemostatic agent could replace the animal-derived products like collagen and gelatin and therewith prevent the potential risk of pathogen transmission.

  8. [Modified polyurethane foam as a local hemostatic agent after dental extractions].

    PubMed

    Selten, M H A; Broekema, F I; Zuidema, J; van Oeveren, W; Bos, R R M

    2013-01-01

    In this split mouth experiment, the feasibility ofpolyurethane foam as a local hemostatic agent after dental extractions was studied. Ten healthy patients underwent 2 extractions ofa dental element in 1 treatment session. The 10 patients were subsequently randomly divided in a gelatin group and a collagen group. In the gelatin group, a polyurethane foam (PU) was applied in 1 extraction socket, while in the other socket a commercially available gelatin foam was applied. In the collagen group, a PU was applied in 1 socket, and a collagen wadding in the other. All hemostats were removed after 2 minutes, after which the degree of coagulation was measured using a thrombin/antithrombin test and a fibrinogen test. This study suggests that polyurethane foam has hemostatic capacity. Large scale clinical research is needed to confirm this finding, and should indicate whether this hemostatic capacity is clinically relevant.

  9. Biomaterials and Advanced Technologies for Hemostatic Management of Bleeding.

    PubMed

    Hickman, DaShawn A; Pawlowski, Christa L; Sekhon, Ujjal D S; Marks, Joyann; Gupta, Anirban Sen

    2018-01-01

    Bleeding complications arising from trauma, surgery, and as congenital, disease-associated, or drug-induced blood disorders can cause significant morbidities and mortalities in civilian and military populations. Therefore, stoppage of bleeding (hemostasis) is of paramount clinical significance in prophylactic, surgical, and emergency scenarios. For externally accessible injuries, a variety of natural and synthetic biomaterials have undergone robust research, leading to hemostatic technologies including glues, bandages, tamponades, tourniquets, dressings, and procoagulant powders. In contrast, treatment of internal noncompressible hemorrhage still heavily depends on transfusion of whole blood or blood's hemostatic components (platelets, fibrinogen, and coagulation factors). Transfusion of platelets poses significant challenges of limited availability, high cost, contamination risks, short shelf-life, low portability, performance variability, and immunological side effects, while use of fibrinogen or coagulation factors provides only partial mechanisms for hemostasis. With such considerations, significant interdisciplinary research endeavors have been focused on developing materials and technologies that can be manufactured conveniently, sterilized to minimize contamination and enhance shelf-life, and administered intravenously to mimic, leverage, and amplify physiological hemostatic mechanisms. Here, a comprehensive review regarding the various topical, intracavitary, and intravenous hemostatic technologies in terms of materials, mechanisms, and state-of-art is provided, and challenges and opportunities to help advancement of the field are discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Application of Absorbable Hemostatic Materials Observed in Thyroid Operation

    NASA Astrophysics Data System (ADS)

    Li, Yan-Ming; Liang, Zhen-Zhen; Song, Yan

    2016-05-01

    To observe the application effects of the absorbable hemostatic materials in thyroid operation. Methods: From May 2014 to January 2015, 100 patients with thyroid surgery in our university affiliated hospital were selected as the research object. Randomly divided into experimental group and control group, 50 cases in each group. Application of absorbable hemostatic hemostatic materials in the experimental group during the operation, the control group using the traditional mechanical methods of hemostasis hemostasis to observe the operation time, bleeding volume, postoperative drainage volume, complications and hospital stay of the two groups. Results: The operation time, bleeding volume, postoperative drainage and hospital stay in the experimental group were significantly lower in the study group than in the control group, and the difference between the two groups was statistically significant (P< 0.05); The satisfaction of patients in the experimental group was significantly higher than that in the control group, the difference was statistically significant in the two groups (P < 0.05); There was no significant difference in the incidence of wound bleeding complications between the study group and the control group (P > 0.05). Conclusion: Absorbable hemostatic materials can effectively shorten the operation time, reduce intraoperative blood loss and postoperative drainage, reduce the length of hospital stay and improve the success rate of surgery and patient satisfaction, which is worthy to be popularized in clinical thyroid surgery.

  11. Hemostatic powder spray: a new method for managing gastrointestinal bleeding

    PubMed Central

    Papafragkakis, Haris; Ofori, Emmanuel; Ona, Mel A.; Krishnaiah, Mahesh; Duddempudi, Sushil; Anand, Sury

    2015-01-01

    Gastrointestinal bleeding is a leading cause of morbidity and mortality in the United States. The management of gastrointestinal bleeding is often challenging, depending on its location and severity. To date, widely accepted hemostatic treatment options include injection of epinephrine and tissue adhesives such as cyanoacrylate, ablative therapy with contact modalities such as thermal coagulation with heater probe and bipolar hemostatic forceps, noncontact modalities such as photodynamic therapy and argon plasma coagulation, and mechanical hemostasis with band ligation, endoscopic hemoclips, and over-the-scope clips. These approaches, albeit effective in achieving hemostasis, are associated with a 5–10% rebleeding risk. New simple, effective, universal, and safe methods are needed to address some of the challenges posed by the current endoscopic hemostatic techniques. The use of a novel hemostatic powder spray appears to be effective and safe in controlling upper and lower gastrointestinal bleeding. Although initial reports of hemostatic powder spray as an innovative approach to manage gastrointestinal bleeding are promising, further studies are needed to support and confirm its efficacy and safety. The aim of this study was to evaluate the technical feasibility, clinical efficacy, and safety of hemostatic powder spray (Hemospray, Cook Medical, Winston-Salem, North Carolina, USA) as a new method for managing gastrointestinal bleeding. In this review article, we performed an extensive literature search summarizing case reports and case series of Hemospray for the management of gastrointestinal bleeding. Indications, features, technique, deployment, success rate, complications, and limitations are discussed. The combined technical and clinical success rate of Hemospray was 88.5% (207/234) among the human subjects and 81.8% (9/11) among the porcine models studied. Rebleeding occurred within 72 hours post-treatment in 38 patients (38/234; 16.2%) and in three porcine

  12. Hemostatic powder spray: a new method for managing gastrointestinal bleeding.

    PubMed

    Changela, Kinesh; Papafragkakis, Haris; Ofori, Emmanuel; Ona, Mel A; Krishnaiah, Mahesh; Duddempudi, Sushil; Anand, Sury

    2015-05-01

    Gastrointestinal bleeding is a leading cause of morbidity and mortality in the United States. The management of gastrointestinal bleeding is often challenging, depending on its location and severity. To date, widely accepted hemostatic treatment options include injection of epinephrine and tissue adhesives such as cyanoacrylate, ablative therapy with contact modalities such as thermal coagulation with heater probe and bipolar hemostatic forceps, noncontact modalities such as photodynamic therapy and argon plasma coagulation, and mechanical hemostasis with band ligation, endoscopic hemoclips, and over-the-scope clips. These approaches, albeit effective in achieving hemostasis, are associated with a 5-10% rebleeding risk. New simple, effective, universal, and safe methods are needed to address some of the challenges posed by the current endoscopic hemostatic techniques. The use of a novel hemostatic powder spray appears to be effective and safe in controlling upper and lower gastrointestinal bleeding. Although initial reports of hemostatic powder spray as an innovative approach to manage gastrointestinal bleeding are promising, further studies are needed to support and confirm its efficacy and safety. The aim of this study was to evaluate the technical feasibility, clinical efficacy, and safety of hemostatic powder spray (Hemospray, Cook Medical, Winston-Salem, North Carolina, USA) as a new method for managing gastrointestinal bleeding. In this review article, we performed an extensive literature search summarizing case reports and case series of Hemospray for the management of gastrointestinal bleeding. Indications, features, technique, deployment, success rate, complications, and limitations are discussed. The combined technical and clinical success rate of Hemospray was 88.5% (207/234) among the human subjects and 81.8% (9/11) among the porcine models studied. Rebleeding occurred within 72 hours post-treatment in 38 patients (38/234; 16.2%) and in three porcine

  13. Hemostatic action of polyurethane foam with 55% polyethylene glycol compared to collagen and gelatin.

    PubMed

    Broekema, Ferdinand I; van Oeveren, Wim; Boerendonk, Andrea; Sharma, Prashant K; Bos, Rudolf R M

    2016-08-12

    For most topical hemostatic agents the mechanism of hemostatic action is not fully understood. This work aimed to investigate the hemostatic mechanism of action and viscoelastic properties of polyurethane foam (PU) in comparison to the widely used collagen and gelatin. The hemostatic mechanism of action of the materials was tested using human whole blood and platelet-poor plasma (PPP). The ability of the hemostatic agent to exert pressure on the wound was quantified in terms of its viscoelastic properties both under dry and wet conditions using a low load compression tester (LLCT). It has been shown that collagen and PU initiate hemostasis through both thrombocyte aggregation and contact activation of the coagulation cascade. Gelatin did not show improved thrombocyte aggregation or initiation of the coagulation cascade compared to the negative control group. PU is more firm under wet conditions and shows more springback than collagen and gelatin. We conclude that PU is promising as a topical hemostatic agent because it initiates both the coagulation cascade and thrombocyte aggregation. Furthermore, it has favorable viscoelastic properties compared to collagen and gelatin which leads to increased pressure on a wound.

  14. The effects of hemostatic agents on peripheral nerve function: an experimental study.

    PubMed

    Alkan, Alper; Inal, Samet; Yildirim, Mehmet; Baş, Burcu; Ağar, Erdal

    2007-04-01

    In the practice of oral and maxillofacial surgery, hemostatic agents are sometimes placed in close proximity to peripheral nerves. In the present study, we evaluated immediate and delayed effects of 4 hemostatic agents (oxidized regenerated cellulose, 5% colloid silver-added gelatine sponge, bovine collagen, bone wax) on peripheral nerve function. A total of 25 rat sciatic nerves were prepared, and the amplitudes were recorded with a physiological data acquisition system. Animals were randomly assigned to 5 groups: control, oxidized regenerated cellulose, gelatine sponge, bone wax, and bovine collagen. The first hour records are defined as immediate effects of these hemostatic agents on nerve function. The animals were then allowed to recover for 4 weeks. At the end of this period, the same surgical and recording procedures were performed. These final records are defined as delayed effects of hemostatic agents on nerve function. According to nerve conduction velocity (NCV) and compound action potential (CAP) values of the experimental groups, early and delayed effects of each hemostatic agent were statistically compared with Bonferroni corrected test (P < .05). Statistically, NCV was significantly reduced, and the CAP was significantly increased 1 hour after surgery (P < .05) in the group of oxidized regenerated cellulose. However, there were no significant differences after 4 weeks compared with the first records. In the gelatine sponge group, CAP was significantly increased 4 weeks after the application. In the bovine collagen and bone wax groups, NCV and CAP values (1 hour and 4 weeks after the application) were not statistically significant compared with initial control records. The present study shows that bovine collagen is the most suitable hemostatic agent applicable for peripheral nerves.

  15. Use of topical hemostatic agents in gynecologic surgery.

    PubMed

    Wysham, Weiya Z; Roque, Dario R; Soper, John T

    2014-09-01

    Sutures, hemoclips, and electrocautery are the primary mechanisms used to achieve hemostasis during gynecologic surgery, but in situations in which these are inadequate or not feasible, an array of hemostatic agents are available to help achieve hemostasis. These agents include physical agents such as cellulose, collagen, or gelatin products as well as biologic agents such as thrombin and fibrin products. Limited data are available on many of these agents, although their use is increasing, sometimes at high costs. In gynecologic surgery, hemostatic agents are likely most effective when used in areas of oozing or slow bleeding and as an adjunct to conventional surgical methods of hemostasis.

  16. Ex-vivo porcine organs with a circulation pump are effective for teaching hemostatic skills

    PubMed Central

    2012-01-01

    Surgical residents have insufficient opportunites to learn basic hemostatic skills from clinical experience alone. We designed an ex-vivo training system using porcine organs and a circulation pump to teach hemostatic skills. Residents were surveyed before and after the training and showed significant improvement in their self-confidence (1.83 ± 1.05 vs 3.33 ± 0.87, P < 0.01) on a 5 point Likert scale. This training may be effective to educate residents in basic hemostatic skills. PMID:22404974

  17. Safety and usability of hemostats, sealants, and adhesives.

    PubMed

    Burks, Sandra; Spotnitz, William

    2014-08-01

    Hemostats, sealants, and adhesives are an integral part of surgical patient care. Nurses who have knowledge about these agents can better help ensure safe, efficient surgical patient care. As a caregiver and patient advocate, the perioperative nurse must understand the most current information about these agents and be prepared to facilitate the transfer of this knowledge to all caregivers. Information about these agents, including the contraindications, warnings, and precautions associated with their use as well as their preparation and application, is provided here. Algorithms designed to clarify the best options for using hemostats, sealants, and adhesives are included as well. Copyright © 2014 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  18. Isolation, Characterization and Evaluation of Collagen from Jellyfish Rhopilema esculentum Kishinouye for Use in Hemostatic Applications.

    PubMed

    Cheng, Xiaochen; Shao, Ziyu; Li, Chengbo; Yu, Lejun; Raja, Mazhar Ali; Liu, Chenguang

    2017-01-01

    Hemostat has been a crucial focus since human body is unable to control massive blood loss, and collagen proves to be an effective hemostat in previous studies. In this study, collagen was isolated from the mesoglea of jellyfish Rhopilema esculentum Kishinouye and its hemostatic property was studied. The yields of acid-soluble collagen (ASC) and pepsin-soluble (PSC) were 0.12% and 0.28% respectively. The SDS-PAGE patterns indicated that the collagen extracted from jellyfish mesoglea was type I collagen. The lyophilized jellyfish collagen sponges were cross-linked with EDC and interconnected networks in the sponges were revealed by scanning electron microscope (SEM). Collagen sponges exhibited higher water absorption rates than medical gauze and EDC/NHS cross-linking method could improve the stability of the collagen sponges. Compared with medical gauze groups, the blood clotting indexes (BCIs) of collagen sponges were significantly decreased (P < 0.05) and the concentration of collagen also had an influence on the hemostatic property (P < 0.05). Collagen sponges had an improved hemostatic ability compared to the gauze control in tail amputation rat models. Hemostatic mechanism studies showed that hemocytes and platelets could adhere and aggregate on the surface of collagen sponge. All properties make jellyfish collagen sponge to be a suitable candidate used as hemostatic material and for wound healing applications.

  19. Isolation, Characterization and Evaluation of Collagen from Jellyfish Rhopilema esculentum Kishinouye for Use in Hemostatic Applications

    PubMed Central

    Cheng, Xiaochen; Liu, Chenguang

    2017-01-01

    Hemostat has been a crucial focus since human body is unable to control massive blood loss, and collagen proves to be an effective hemostat in previous studies. In this study, collagen was isolated from the mesoglea of jellyfish Rhopilema esculentum Kishinouye and its hemostatic property was studied. The yields of acid-soluble collagen (ASC) and pepsin-soluble (PSC) were 0.12% and 0.28% respectively. The SDS-PAGE patterns indicated that the collagen extracted from jellyfish mesoglea was type I collagen. The lyophilized jellyfish collagen sponges were cross-linked with EDC and interconnected networks in the sponges were revealed by scanning electron microscope (SEM). Collagen sponges exhibited higher water absorption rates than medical gauze and EDC/NHS cross-linking method could improve the stability of the collagen sponges. Compared with medical gauze groups, the blood clotting indexes (BCIs) of collagen sponges were significantly decreased (P < 0.05) and the concentration of collagen also had an influence on the hemostatic property (P < 0.05). Collagen sponges had an improved hemostatic ability compared to the gauze control in tail amputation rat models. Hemostatic mechanism studies showed that hemocytes and platelets could adhere and aggregate on the surface of collagen sponge. All properties make jellyfish collagen sponge to be a suitable candidate used as hemostatic material and for wound healing applications. PMID:28103327

  20. Preparation of Chitosan-Based Hemostatic Sponges by Supercritical Fluid Technology

    PubMed Central

    Song, Hu-Fan; Chen, Ai-Zheng; Wang, Shi-Bin; Kang, Yong-Qiang; Ye, Shi-Fu; Liu, Yuan-Gang; Wu, Wen-Guo

    2014-01-01

    Using ammonium bicarbonate (AB) particles as a porogen, chitosan (CS)-based hemostatic porous sponges were prepared in supercritical carbon dioxide due to its low viscosity, small surface tension, and good compatibility with organic solvent. Fourier transform infrared spectroscopy (FTIR) spectra demonstrated that the chemical compositions of CS and poly-(methyl vinyl ether-co-maleic anhydride) (PVM/MA) were not altered during the phase inversion process. The morphology and structure of the sponge after the supercritical fluid (SCF) process were observed by scanning electron microscopy (SEM). The resulting hemostatic sponges showed a relatively high porosity (about 80%) with a controllable pore size ranging from 0.1 to 200 μm. The concentration of PVM/MA had no significant influence on the porosity of the sponges. Comparative experiments on biological assessment and hemostatic effect between the resulting sponges and Avitene® were also carried out. With the incorporation of PVM/MA into the CS-based sponges, the water absorption rate of the sponges increased significantly, and the CS-PVM/MA sponges showed a similar water absorption rate (about 90%) to that of Avitene®. The results of the whole blood clotting experiment and animal experiment also demonstrated that the clotting ability of the CS-PVM/MA sponges was similar to that of Avitene®. All these results elementarily verified that the sponges prepared in this study were suitable for hemostasis and demonstrated the feasibility of using SCF-assisted phase inversion technology to produce hemostatic porous sponges. PMID:28788577

  1. Hemostatic efficacy of local chitosan linear polymer granule in an experimental sheep model with severe bleeding of arteria and vena femoralis.

    PubMed

    Ersoy, Gürkan; Rodoplu, Ülkümen; Yılmaz, Osman; Gökmen, Necati; Doğan, Alper; Dikme, Özgür; Aydınoğlu, Aslı; Orhon, Okyanus

    2016-05-01

    The aim of the present study was to evaluate the hemostatic effect of chitosan linear polymer in a sheep model with femoral bleeding. Following induction of anesthesia and intubation of sheep, groin injury was induced to initiate hemorrhage. Animals were randomly assigned to study and control groups. In the control group, absorbent pads were packed on the wound, and pressure was supplied by a weight placed over the dressing. In the study group, chitosan linear polymer was poured onto the bleeding site; absorbent pads and pressure were applied in the same manner. At 5-min intervals, bleeding was evaluated. Primary endpoint was time to hemostasis. Bleeding had stopped by the 1st interval in 5 members of the study group, and by the 2nd interval in 1 member. One sheep was excluded. The bleeding stopped after the 1st interval in 1 member of the control group and after the 2nd interval in 4 members. Bleeding stopped in 2 cases following ligation of the bleeding vessel. Hemostasis was achieved earlier in the study group, compared to the control group, and the difference was statistically significant. Hemostasis was achieved earlier following application of chitosan linear polymer.

  2. Incidence of thromboembolic events after use of gelatin-thrombin-based hemostatic matrix during intracranial tumor surgery.

    PubMed

    Gazzeri, Roberto; Galarza, Marcelo; Conti, Carlo; De Bonis, Costanzo

    2018-01-01

    Association between the use of hemostatic agents made from collagen/gelatin mixed with thrombin and thromboembolic events in patients undergoing tumor resection has been suggested. This study evaluates the relationship between flowable hemostatic matrix and deep vein thrombosis in a large cohort of patients treated for brain tumor removal. The authors conducted a retrospective, multicenter, clinical review of all craniotomies for tumor removal performed between 2013 and 2014. Patients were classified in three groups: group I (flowable gelatin hemostatic matrix with thrombin), group II (gelatin hemostatic without thrombin), and group III (classical hemostatic). A total of 932 patients were selected: tumor pathology included 441 gliomas, 296 meningiomas, and 195 metastases. Thromboembolic events were identified in 4.7% of patients in which gelatin matrix with thrombin was applied, in 8.4% of patients with gelatin matrix without thrombin, and in 3.6% of cases with classical methods of hemostasis. Patients with venous thromboembolism had an increased proportion of high-grade gliomas (7.2%). Patients receiving a greater dose than 10 ml gelatin hemostatic had a higher rate of thromboembolic events. Intracranial hematoma requiring reintervention occurred in 19 cases: 4.5% of cases of group III, while reoperation was performed in 1.3 and 1.6% of patients in which gelatin matrix with or without thrombin was applied. Gelatin matrix hemostat is an efficacious tool for neurosurgeons in cases of difficult intraoperative bleeding during cranial tumor surgery. This study may help to identify those patients at high risk for developing thromboembolism and to treat them accordingly.

  3. Osteogenic differentiation of preosteoblasts on a hemostatic gelatin sponge

    PubMed Central

    Kuo, Zong-Keng; Lai, Po-Liang; Toh, Elsie Khai-Woon; Weng, Cheng-Hsi; Tseng, Hsiang-Wen; Chang, Pei-Zen; Chen, Chih-Chen; Cheng, Chao-Min

    2016-01-01

    Bone tissue engineering provides many advantages for repairing skeletal defects. Although many different kinds of biomaterials have been used for bone tissue engineering, safety issues must be considered when using them in a clinical setting. In this study, we examined the effects of using a common clinical item, a hemostatic gelatin sponge, as a scaffold for bone tissue engineering. The use of such a clinically acceptable item may hasten the translational lag from laboratory to clinical studies. We performed both degradation and biocompatibility studies on the hemostatic gelatin sponge, and cultured preosteoblasts within the sponge scaffold to demonstrate its osteogenic differentiation potential. In degradation assays, the gelatin sponge demonstrated good stability after being immersed in PBS for 8 weeks (losing only about 10% of its net weight and about 54% decrease of mechanical strength), but pepsin and collagenases readily biodegraded it. The gelatin sponge demonstrated good biocompatibility to preosteoblasts as demonstrated by MTT assay, confocal microscopy, and scanning electron microscopy. Furthermore, osteogenic differentiation and the migration of preosteoblasts, elevated alkaline phosphatase activity, and in vitro mineralization were observed within the scaffold structure. Each of these results indicates that the hemostatic gelatin sponge is a suitable scaffold for bone tissue engineering. PMID:27616161

  4. A simple hemostasis model for the quantitative evaluation of hydrogel-based local hemostatic biomaterials on tissue surface.

    PubMed

    Murakami, Yoshihiko; Yokoyama, Masayuki; Nishida, Hiroshi; Tomizawa, Yasuko; Kurosawa, Hiromi

    2008-09-01

    Several hemostat hydrogels are clinically used, and some other agents are studied for safer, more facile, and more efficient hemostasis. In the present paper, we proposed a novel method to evaluate local hemostat hydrogel on tissue surface. The procedure consisted of the following steps: (step 1) a mouse was fixed on a cork board, and its abdomen was incised; (step 2) serous fluid was carefully removed because it affected the estimation of the weight gained by the filter paper, and parafilm and preweighted filter paper were placed beneath the liver (parafilm prevented the filter paper's absorption of gradually oozing serous fluid); (step 3) the cork board was tilted and maintained at an angle of about 45 degrees so that the bleeding would more easily flow from the liver toward the filter paper; and (step 4) the bleeding lasted for 3 min. In this step, a hemostat was applied to the liver wound immediately after the liver was pricked with a needle. We found that (1) a careful removal of serous fluid prior to a bleeding and (2) a quantitative determination of the amount of excess aqueous solution that oozed out from a hemostat were important to a rigorous evaluation of hemostat efficacy. We successfully evaluated the efficacy of a fibrin-based hemostat hydrogel by using our method. The method proposed in the present study enabled the quantitative, accurate, and easy evaluation of the efficacy of local hemostatic hydrogel which acts as tissue-adhesive agent on biointerfaces.

  5. Marginal integrity of low-shrinkage and methacrylate-based composite resins: Effect of three different hemostatic agents

    PubMed Central

    Khoroushi, Maryam; Sahraneshin-Samani, Mahsa

    2016-01-01

    Background Moisture control is very important in restorative procedures in dentistry. Use of hemostatic agents helps control moisture; however, they might result in changes on enamel and dentin surfaces, affecting composite resin bond quality. The aim of this in vitro study was to evaluate the marginal microleakage of two different composite resins with the use of three different hemostatic agents. Material and Methods Standardized Class V cavities were prepared on the buccal and lingual surfaces of 48 premolars with cervical margins 1 mm apical to the cementoenamel junction (CEJ). The samples were randomly divided into 8 groups. In groups 1 to 4, an etch-and-rinse adhesive (Adper Single Bond) was applied as the bonding system, followed by exposure to different hemostatic agent: group 1: no hemostatic agent (control); group 2: ViscoStat; group 3: ViscoStat Clear; and group 4: trichloracetic acid, as hemostatic agents. The cavities were restored with Z-250 composite resin. In group 5 to 8 Silorane System Adhesive (Filtek P90 Adhesive) was applied as a bonding agent, followed by exposure to different hemostatic agents in a manner similar to that in groups 1to 4. The cavities were restored with Filtek P90, a low-shrinkage composite resin. The samples in each group were evaluated for dye penetration under a stereomicroscope at ×36 after 24 hours and a 500-round thermocycling procedure at enamel and dentin margins. Statistical analysis was carried out using Kruskal-Wallis and Mann-Whitney tests (α=0.05). Results Z-250 composite resin exhibited significantly higher dentin microleakage scores compared to Filtek P90 (P = 0.004). Trichloracetic acid increased dentin microleakage with Filtek P90 (P=0.033). Conclusions Under the limitations of this in vitro study, application of hemostatic agents did not affect microleakage of the two tested composite resins except for trichloracetic acid that increased marginal microleakage when used with Filtek P90. Key words

  6. Hemostatic kaolin-polyurethane foam composites for multifunctional wound dressing applications.

    PubMed

    Lundin, Jeffrey G; McGann, Christopher L; Daniels, Grant C; Streifel, Benjamin C; Wynne, James H

    2017-10-01

    There are numerous challenges associated with the acute care of traumatic limb injuries in forward military settings. A lack of immediate medical facilities necessitates that the wound dressing perform multiple tasks including exudate control, infection prevention, and physical protection of the wound for extended periods of time. Here, kaolin was incorporated into recently developed robust polyurethane (PU) hydrogel foams at 1-10wt% in an effort to impart hemostatic character. ATR-IR and gel fraction analysis demonstrated that the facile, one-pot synthesis of the PU hydrogel was unaffected by kaolin loading, as well as the use of a non-toxic catalyst, which significantly improved cytocompatibility of the materials. Kaolin was generally well dispersed throughout the PU matrix, though higher loadings exhibited minor evidence of aggregation. Kaolin-PU composites exhibited burst release of ciprofloxacin over 2h, the initial release rates of which increased with kaolin loading. Kaolin loading imparted excellent hemostatic character to the PU foams at relatively low loading levels (5wt%). This work demonstrates the simple and inexpensive synthesis of robust, hemostatic, and absorptive kaolin-PU foams that have promising potential as multifunctional wound dressing materials. Published by Elsevier B.V.

  7. Basic in vitro experiment on the adhesive effects of sheet-type hemostatic agents used in combination with a liquid fibrin sealant.

    PubMed

    Ishii, Keiichi; Kawashima, Hideki; Hayama, Takuma; Mayabashira, Sumika; Oka, Shiro; Sugimoto, Toshikado

    2011-11-01

    Various hemostatic agents have been used quite effectively for hemostasis, as well as for providing effective adhesion during laparoscopic partial nephrectomies. In this study, we investigated the adhesiveness to the renal tissue of some sheet-type hemostatic agents used in combination with a liquid fibrin sealant. In Experiment A, component solutions of the fibrin glue (liquid fibrin sealant) were dripped onto a kite string placed annularly on a porcine kidney slice. Then, one of the sheet-type hemostats--namely, the collagen, gelatin, or cellulose hemostat--was placed on the slices, and a string scale was used to measure the force needed to pull the string apart vertically from the kidney slice. Twelve slices were used for each group, and the weight data were analyzed statistically. The tissue adhering to each sheet-type hemostatic agent was fixed in formalin and sliced and then examined by light microscopy after hematoxylin and eosin staining. In Experiment B, the solutions were dripped onto the sheet-type hemostatic agent placed first on the slice, and the force needed for pulling apart the hemostat sheet from the slice was similarly examined. The combination of fibrin glue plus a collagen hemostat was clearly superior in Experiment A, but the hemostat and renal tissue could be pulled apart more easily in Experiment B. These results showed that fibrin glue could not exert its expected adhesive effect unless it is used in combination with another hemostatic agent or is directly applied to renal tissue. It is important to obtain further comparative data among agents and select the appropriate agents, taking into consideration the type of surgery.

  8. New generation tissue sealants and hemostatic agents: innovative urologic applications.

    PubMed

    Traver, Michael A; Assimos, Dean G

    2006-01-01

    Control of blood loss during urologic surgery is paramount to the success of patient recovery. Hemostatic agents and tissue sealants are used routinely to prevent excess blood loss and in reconstruction during surgical repair. Some of the available products include thrombin sealant, fibrin glue, bovine serum/albumin/glutaraldehyde, and gelatin matrix. Each of these agents differs in mechanism, cost, and application. Complications can include allergic reactions or thromboembolism and the risk of contracting bovine spongiform encephalitis or hepatitis. Many new hemostatic agents are being developed and approved. The benefits and risks of use of these agents versus conventional treatment need to be considered on a case-by-case basis by the surgeon.

  9. Effect of iodinated low-osmolar contrast media on the hemostatic system after intraarterial and intravenous contrast administration.

    PubMed

    Lukasiewicz, A; Lebkowska, U; Galar, M

    2012-01-01

    Some of the adverse clinical effects of intravascular radiological contrast agents include the interference of these contrast media with normal hemostatic processes. The aim of this report was to investigate in vivo whether a non-ionic iodinated contrast agent possess prothrombotic or anticoagulant properties. Hemostatic parameters: vWF (von Willebrand factor), F1+2 (prothrombin fragments 1+2), TAT (thrombin-antithrombin complexes), D-Dimer, β-TG (beta-thromboglobulin) were measured in a group of 35 patients. Blood samples for laboratory investigations were collected before and 30 min after the administration of a iodine contrast agent. There was observed statistically highly significant contrast-induced increase in TAT and F1+2 (p = 0.005 and p = 0.008, respectively). D-Dimer increase and decrease of β-TG and vWF after contrast medium administration were non significant. The volume of contrast medium has no influence on the assessed hemostatic parameters, while the type of contrast medium and/or the route of the contrast administration may significantly affect hemostatic parameters. We found significant effects of non-ionic agents on hemostatic activation. These effects may be important for adverse reactions and for thromboembolic complications.

  10. Hemostasis in a noncompressible hemorrhage model: an end-user evaluation of hemostatic agents in a proximal arterial injury.

    PubMed

    Satterly, Steven; Nelson, Daniel; Zwintscher, Nathan; Oguntoye, Morohunranti; Causey, Wayne; Theis, Bryan; Huang, Raywin; Haque, Mohamad; Martin, Matthew; Bickett, Gerald; Rush, Robert M

    2013-01-01

    1. Evaluate hemostatic bandages by the end user using subjective and objective criteria. 2. Determine if user training and education level impact overall hemostatic outcomes. 3. Our hypothesis was that prior medical training would be directly linked to improved hemostatic outcomes in noncompressible hemorrhage indepen- dent of dressing used. Military personnel were given standardized instruction on hemostatic dressings as part of a tactical combat casualty care course (TC3). Soldiers were randomized to a hemostatic dressing. Proximal arterial (femoral and axillary) injuries were created in extremities of live tissue models (goat or pig). Participants attempted hemostasis through standardized dressing application. Evaluation of hemostasis was performed at 2- and 4-minute intervals by physicians blinded to participants' training level. Military personnel that are due to deploy are given "refresher" instruction by their units as well as participating in the TC3 to further hone their medical skills prior to deployment. The TC3 is simulation training designed to simulate combat environments and real-life trauma scenarios. Military personnel due to deploy, physicians (residents and board certified surgeons), animal care technicians, and veterinarian support. Celox 42 (33%), ChitoGauze 11 (9%), Combat Gauze 45 (35%), and HemCon wafer 28 (22%) bandages were applied in 126 arterial injuries created in 45 animals in a standardized model of hemorrhage. Overall, no significant difference in hemostasis and volume of blood loss was seen between the 4 dressings at 2 or 4 minutes. Combat gauze was the most effective at controlling hemorrhage, achieving 83% hemostasis by 4 minutes. Combat gauze was also rated as the easiest dressing to use by the soldiers (p<0.05). When compared to nonmedical personnel, active duty soldiers with prior medical training improved hemostasis at 4 minutes by 20% (p = 0.05). There is no significant difference in hemostasis between hemostatic bandages for

  11. Hemostatic properties of the free-electron laser

    NASA Astrophysics Data System (ADS)

    Cram, Gary P., Jr.; Copeland, Michael L.

    1998-09-01

    We have investigated the hemostatic properties of the free-electron laser (FEL) and compared these properties to the most commonly used commercial lasers in neurosurgery, CO 2 and Nd:YAG, using an acute canine model. Arterial and venous vessels, of varying diameters from 0.1 to 1.0 mm, were divided with all three lasers. Analysis of five wavelengths of the FEL (3.0, 4.5, 6.1, 6.45, and 7.7 microns) resulted in bleeding without evidence of significant coagulation, regardless of whether the vessel was an artery or vein. Hemorrhage from vessels less than 0.4 mm diameter was subsequently easily controlled with Gelfoam® (topical hemostatic agent) alone, whereas larger vessels required bipolar electrocautery. No significant charring, or contraction of the surrounding parenchyma was noted with any of the wavelengths chosen from FEL source. The CO 2 laser, in continuous mode, easily coagulated vessels with diameters of 4 mm and less, while larger vessels displayed significant bleeding requiring bipolar electrocautery for control. Tissue charring was noted with application of the CO 2 laser. In super pulse mode, the CO 2 laser exhibited similar properties, including significant charring of the surrounding parenchyma. The Nd:YAG coagulated all vessels tested up to 1.4 mm, which was the largest diameter cortical artery found, however this laser displayed significant and extensive contraction and retraction of the surrounding parenchyma. In conclusion, the FEL appears to be a poor hemostatic agent. Our results did not show any benefit of the FEL over current conventional means of achieving hemostasis. However, control of hemorrhage was easily achieved with currently used methods of hemostasis, namely Gelfoam® or bipolar electrocuatery. Although only cortical vessels in dogs were tested, we feel this data can be applied to all animals, including humans, and the peripheral, as well as central, vasculature, as our data on the CO 2 and Nd:YAG appear to closely support previous

  12. The hemostatic activity of cryopreserved platelets is mediated by phosphatidylserine-expressing platelets and platelet microparticles.

    PubMed

    Johnson, Lacey; Coorey, Craig P; Marks, Denese C

    2014-08-01

    Cryopreservation of platelets (PLTs) at -80°C with dimethyl sulfoxide (DMSO) can extend the shelf life from 5 days to 2 years. Cryopreserved PLTs are reported to have a greater in vivo hemostatic effect than liquid-stored PLTs. As such, the aim of this study was to understand the mechanisms responsible for the hemostatic potential of cryopreserved PLTs and the contribution of the reconstitution solution to this activity. DMSO (5% final concentration) was added to buffy coat-derived PLTs, followed by prefreeze removal of DMSO and storage at -80°C. Cryopreserved PLTs (n=8 per group) were thawed at 37°C, reconstituted with either 1 unit of thawed frozen plasma or PLT additive solution (PAS-G). In vitro assays were performed before freezing and after thawing to assess the hemostatic activity of PLTs. Cryopreserved PLTs expressed high levels of phosphatidylserine and contained significantly more phosphatidylserine-positive PLT microparticles than liquid-stored PLTs. This was accompanied by a significant decrease in the time to clot formation and clot strength, as measured by thromboelastography. The supernatant from cryopreserved PLTs was sufficient to reduce the phosphatidylserine-dependent clotting time and increase the thrombin generation potential. Overall, plasma-reconstituted cryopreserved PLTs were more procoagulant than those reconstituted in PAS-G. PLT cryopreservation results in the generation of phosphatidylserine-expressing PLT microparticles which contribute to the hemostatic activity. Understanding the hemostatic activity of these components may assist in extending the use of these specialized components beyond military applications. © 2014 Australian Red Cross Blood Service. Transfusion © 2014 AABB.

  13. Mechanistic investigation of a hemostatic keratin biomaterial

    NASA Astrophysics Data System (ADS)

    Rahmany, Maria Bahawdory

    Traumatic injury leads to more productive years lost than heart disease, cancer and stroke combined. Trauma is often accompanied and complicated by uncontrolled bleeding. Human hair keratin biomaterials have demonstrated efficacy in controlling hemorrhage in both small and large animal models; however little is known about the mechanism by which these proteins aid in blood clotting. Inspection of the amino acid sequence of known keratins shows the presence of several cellular binding motifs, suggesting a possible mechanism and potentially eliminating the need to functionalize the material's surface for cellular interaction. In addition to small animal studies, the hemostatic activity of keratin hydrogels was explored through porcine hemorrhage models representing both a high flow and low flow bleed. In both studies, keratin hydrogels appeared to lead to a significant reduction in blood loss. The promising results from these in vivo studies provided the motivation for this project. The objective of this dissertation work was to assess the mechanism of action of a hemostatic keratin biomaterial, and more broadly assess the biomaterial-cellular interaction(s). It is our hypothesis that keratin biomaterials have the capacity to specifically interact with cells and lead to propagation of intracellular signaling pathway, specifically contributing to hemostasis. Through application of biochemical and molecular tools, we demonstrate here that keratin biomaterials contribute to hemostasis through two probable mechanisms; integrin mediated platelet adhesion and increased fibrin polymerization. Platelets are the major cell type involved in coagulation both by acting as a catalytic surface for the clotting cascade and adhering to extracellular matrix (ECM) proteins providing a soft platelet plug. Because keratin biomaterials have structural and biochemical characteristics similar to ECM proteins, we utilized several adhesion assays to investigate platelet adhesion to keratin

  14. Variation in hospital resource use and cost among surgical procedures using topical absorbable hemostats

    PubMed Central

    Martyn, Derek; Meckley, Lisa M; Miyasato, Gavin; Lim, Sangtaeck; Riebman, Jerome B; Kocharian, Richard; Scaife, Jillian G; Rao, Yajing; Corral, Mitra

    2015-01-01

    Background Adjunctive hemostats are used to assist with the control of intraoperative bleeding. The most common types are flowables, gelatins, thrombins, and oxidized regenerated celluloses (ORCs). In the US, Surgicel® products are the only US Food and Drug Administration-approved ORCs. Objective To compare the outcomes of health care resource utilization (HRU) and costs associated with using ORCs compared to other adjunctive hemostats (OAHs are defined as flowables, gelatins, and topical thrombins) for surgical procedures in the US inpatient setting. Patients and methods A retrospective, US-based cohort study was conducted using hospital inpatient discharges from the 2011–2012 calendar years in the Premier Healthcare Database. Patients with either an ORC or an OAH who underwent a cardiovascular procedure (valve surgery and/or coronary artery bypass graft surgery), carotid endarterectomy, cholecystectomy, or hysterectomy were included. Propensity score matching was used to create comparable groups of ORC and OAH patients. Clinical, economic, and HRU outcomes were compared. Results The propensity score matching created balanced patient cohorts for cardiovascular procedure (22,718 patients), carotid endarterectomy (10,890 patients), cholecystectomy (6,090 patients), and hysterectomy (9,348 patients). In all procedures, hemostatic agent costs were 28%–56% lower for ORCs, and mean hemostat units per discharge were 16%–41% lower for ORCs compared to OAHs. Length of stay and total procedure costs for patients treated with ORCs were lower for carotid endarterectomy patients (0.3 days and US$700) and for cholecystectomy patients (1 day and US$3,350) (all P<0.001). Conclusion Costs and HRU for patients treated with ORCs were lower than or similar to patients treated with OAHs. Proper selection of the appropriate hemostatic agents has the potential to influence clinical outcomes and treatment costs. PMID:26604807

  15. Different chemical groups modification on the surface of chitosan nonwoven dressing and the hemostatic properties.

    PubMed

    Yan, Dong; Hu, Shihao; Zhou, Zhongzheng; Zeenat, Shah; Cheng, Feng; Li, Yang; Feng, Chao; Cheng, Xiaojie; Chen, Xiguang

    2018-02-01

    The hemostatic properties of surface modified chitosan nonwoven had been investigated. The succinyl groups, carboxymethyl groups and quaternary ammonium groups were introduced into the surface of chitosan nonwoven (obtained NSCS, CMCS and TMCS nonwoven, respectively). For blood clotting, absorbance value (0.105±0.03) of NSCS1 nonwoven was the smallest (CS 0.307±0.002, NSCS2 0.148±0.002, CMCS1 0.195±0.02, CMCS2 0.233±0.001, TMCS1 0.191±0.002, TMCS2 0.345±0.002), which indicated the stronger hemostatic potential. For platelet aggregation, adenosine diphosphate agonist was added to induce the nonwoven to adhered platelets. The aggregation of platelet with TMCS2 nonwoven was highest (10.97±0.16%). Further research of blood coagulation mechanism was discussed, which indicated NSCS and CMCS nonwoven could activate the intrinsic pathway of coagulation to accelerate blood coagulation. NSCS1 nonwoven showed the shortest hemostatic time (147±3.7s) and the lowest blood loss (0.23±0.05g) in a rabbit ear artery injury model. These results demonstrated that these surface modified chitosan nonwoven dressings could use as a promising hemostatic intervention, especially NSCS nonwoven dressing. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Longitudinal association of hemostatic factors with risk for cancers of the breast, colorectum, and lung among postmenopausal women.

    PubMed

    Kabat, Geoffrey C; Salazar, Christian R; Zaslavsky, Oleg; Lane, Dorothy S; Rohan, Thomas E

    2016-09-01

    The aim of this study was to examine whether hemostatic factors associated with coagulation and inflammation pathways are associated with cancer risk in postmenopausal women. We used data from the Women's Health Initiative study to examine the association of plasma fibrinogen levels, factor VII antigen activity, and factor VII concentration measured at baseline and during follow-up with the risk for cancers of the breast, colorectum, and lung. Among 5287 women who were followed up for a median of 11.4 years, 275 cases of breast cancer, 102 cases of colorectal cancer, and 90 cases of lung cancer were identified. Cox proportional hazards models were used to estimate hazard ratios and 95% confidence intervals for the association of hemostatic factors with each cancer. Hemostatic factors were not associated with breast cancer in either baseline or longitudinal analyses. Baseline hemostatic factors showed weak associations with colorectal cancer; however, no association was seen in longitudinal analyses. Fibrinogen was positively associated with lung cancer in both baseline and longitudinal analyses; the association was seen only in never and former smokers, not in current smokers. We found no evidence of an association between hemostatic factors and breast or colorectal cancer in postmenopausal women. The positive association of fibrinogen levels with lung cancer requires confirmation in larger studies.

  17. 21 CFR 878.4490 - Absorbable hemostatic agent and dressing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Absorbable hemostatic agent and dressing. 878.4490 Section 878.4490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4490 Absorbable...

  18. 21 CFR 878.4490 - Absorbable hemostatic agent and dressing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Absorbable hemostatic agent and dressing. 878.4490 Section 878.4490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4490 Absorbable...

  19. 21 CFR 878.4490 - Absorbable hemostatic agent and dressing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbable hemostatic agent and dressing. 878.4490 Section 878.4490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4490 Absorbable...

  20. 21 CFR 878.4490 - Absorbable hemostatic agent and dressing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Absorbable hemostatic agent and dressing. 878.4490 Section 878.4490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4490 Absorbable...

  1. 21 CFR 878.4490 - Absorbable hemostatic agent and dressing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Absorbable hemostatic agent and dressing. 878.4490 Section 878.4490 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4490 Absorbable...

  2. Comparison of Hemostasis Times With a Kaolin-Based Hemostatic Pad (QuikClot Radial) vs Mechanical Compression (TR Band) Following Transradial Access: A Pilot Prospective Study.

    PubMed

    Roberts, Jonathan S; Niu, Jianli; Pastor-Cervantes, Juan A

    2017-10-01

    Hemostasis following transradial access (TRA) is usually achieved by mechanical compression. We investigated use of the QuikClot Radial hemostasis pad (Z-Medica) compared with the TR Band (Terumo Medical) to shorten hemostasis after TRA. Thirty patients undergoing TRA coronary angiography and/or percutaneous coronary intervention were randomized into three cohorts post TRA: 10 patients received mechanical compression with the TR Band, 10 patients received 30 min of compression with the QuikClot Radial pad, and 10 patients received 60 min of compression with the QuikClot Radial pad. Times to hemostasis and access-site complications were recorded. Radial artery patency was evaluated 1 hour after hemostasis by the reverse Barbeau's test. There were no differences in patient characteristics, mean dose of heparin (7117 ± 1054 IU), or mean activated clotting time value (210 ± 50 sec) at the end of procedure among the three groups. Successful hemostasis was achieved in 100% of patients with both the 30-min and 60-min compression groups using the QuikClot pad. Hemostasis failure occurred in 50% of patients when the TR Band was initially weaned at the protocol-driven time (40 min after sheath removal). Mean compression time for hemostasis with the TR Band was 149.4 min compared with 30.7 min and 60.9 min for the 30-min and 60-min QuikClot groups, respectively. No radial artery occlusion occurred in any subject at the end of the study. Use of the QuikClot Radial pad following TRA in this pilot trial significantly shortened hemostasis times when compared with the TR Band, with no increased complications noted.

  3. Sports-related pads.

    PubMed

    Dickens, Rio; Adams, Brian B; Mutasim, Diya F

    2002-05-01

    Knuckle pads, first described by Garrod in 1893, 1 are benign, asymptomatic, well- circumscribed, smooth, firm, skin colored papules, nodules, or plaques. They most commonly occur on the dorsal aspect of the proximal interphalangeal joint of the finger, 2 but also may occur on the dorsal aspects of the foot over joints. 3-5 Knuckle pads may be inherited or acquired. 1 While some authors suggest that trauma is not a significant factor, 6 acquired knuckle pads have been associated with repetitive friction and trauma, 2,7 and may resemble athlete's nodules (also referred to as collagenomas). 1 Histologically, knuckle pads are characterized by hyperkeratosis, hypergranulosis, proliferation of fibroblasts and capillaries, and thickened and irregular collagen bundles. 1 Few cases of knuckle pads involving the lower extremities have been reported. 7 Knuckle pads of the feet have been described in association with inherited syndromes, such as acrokeratoelastoidosis Costa, 3 a syndrome of knuckle pads, leukonychia and deafness, 4 and a syndrome of knuckle pads, leukonychia, deafness and keratosis palmoplantaris. 5 We report a case that illustrates an unusual presentation of acquired knuckle pads of the feet secondary to repetitive friction from athletic gear.

  4. [Preliminary evaluation on seroma prevention and treatment with transposition of tissue flaps and arista hemostatic powder].

    PubMed

    Zhang, Ruming; Tan, Yiwen; Wang, Heqi

    2006-12-01

    To investigate and evaluate prevention and treatment of seroma by transposition of tissue flaps and Arista hemostatic powder after regional lymph node resection in patients with malignant tumors. Twelve patients (6 males, 6 females; aged 31-81 years, with metastatic tumors underwent prevention and treatment of seroma with the tissue flaps and Arista hemostatic powder spray after regional lymph node resection. The metastatic tumors involved the axilla in 1 patient with breast carcinoma, the iliac and inguinal regions in 2 patients with carcinomas of the uterine cervix and the rectum, and the inguinal region in 9 patients, including 4 patients with malignant fibrous histiocytoma(3 in the thigh, 1 in the leg), 2 patients with squamous carcinomas in the leg, 1 patient with synovial sarcoma in the knee, 1 patient with epithelioid sarcoma in the leg, and 1 patient with malignant melanoma in the foot. As for the lymph node removal therapy. 1 patient underwent axillary lymph node removal, 2 patients underwent lymph node removal in theiliac and inguinal regions, and 9 patients underwent lymph node removal in the inguinal region. Meanwhile, of the 12 patients, 6 patients underwent transposition of sartorius flaps with Arista hemostatic powder, 3 patients underwent transposition of the rectus abdominis myocutaneous flaps (including 2 patients treated with Arista spray befor the wound closure and 1 patient treated by transposition of local skin flaps with Arista spray used again),and 3 patients underwent only the suturing of the wounds combined with Arista. At the same time, of the 12 patients,only 4 patient underwent the transplantation of artificial blood vessels. The follow-up for 2-10 months after operation revealed that 10 patients, who had received the transposition of tissue flaps and the spray of Arista hemostatic powder, had the first intention of the incision heal with seroma cured. Nine patients were given a preventive use of Arista hemostatic powder and therefore

  5. CFD Analysis of A Starved Four-Pad Tilting-Pad Journal Bearing with An Elastic Support of Pads

    NASA Astrophysics Data System (ADS)

    Parovay, E. F.; Falaleev, S. V.

    2018-01-01

    Tilting-pad journal bearings are widely used in technics. Oil starvation operation regime is not common for hydrodynamic bearings. However, correctly designed low-flow journal bearing have to operate efficiently and consistently on high rotor speeds. An elastic support of bearing pads is a set of elastic pins made of steel. Elastic support allows pads to self-align and achieve an optimal operational mode. The article presents the thermohydrodynamic performance of an axial journal bearing. The study deals with 60 mm diameter four-pad tilting-pad journal bearing, submitted to a static load varying from 1000 to 30000 N with a rotating speed varying from 1000 to 10000 rpm. The investigation focuses on numerical studying the characteristics of low-flow tilting-pad journal bearings under oil starvation conditions. Dependencies of the bearing performance on the load, rotational speed of the shaft, and the size of the radial clearance are presented.

  6. Antifibrinolytic agents and desmopressin as hemostatic agents in cardiac surgery.

    PubMed

    Erstad, B L

    2001-09-01

    To review the use of systemic hemostatic medications for reducing bleeding and transfusion requirements with cardiac surgery. Articles were obtained through computerized searches involving MEDLINE (from 1966 to September 2000). Additionally, several textbooks containing information on the diagnosis and management of bleeding associated with cardiac surgery were reviewed. The bibliographies of retrieved publications and textbooks were reviewed for additional references. Due to the large number of randomized investigations involving systemic hemostatic medications for reducing bleeding associated with cardiac surgery, the article selection process focused on recent randomized controlled trials, metaanalyses and pharmacoeconomic evaluations. The primary outcomes extracted from the literature were blood loss and associated transfusion requirements, although other outcome measures such as mortality were extracted when available. Although the majority of investigations for reducing cardiac bleeding and transfusion requirements have involved aprotinin, evidence from recent meta-analyses and randomized trials indicates that the synthetic antifibrinolytic agents, aminocaproic acid and tranexamic acid, have similar clinical efficacy. Additionally, aminocaproic acid (and to a lesser extent tranexamic acid) is much less costly. More comparative information of hemostatic agents is needed retative to other outcomes (eg., reoperation rates, myocardial infarction, stroke). There is insufficient evidence to recommend the use of desmopressin for reducing bleeding and transfusion requirements in cardiac surgery, although certain subsets of patients may benefit from its use. Of the medications that have been used to reduce bleeding and transfusion requirements with cardiac surgery, the antifibrinolytic agents have the best evidence supporting their use. Aminocaproic acid is the least costly therapy based on medication costs and transfusion requirements.

  7. Hemostatic granules and dressing prepared from formulations of carboxymethyl cellulose, kappa-carrageenan and polyethylene oxide crosslinked by gamma radiation

    NASA Astrophysics Data System (ADS)

    Barba, Bin Jeremiah D.; Aranilla, Charito T.; Relleve, Lorna S.; Cruz, Veriza Rita C.; Vista, Jeanina Richelle; Abad, Lucille V.

    2018-03-01

    Uncontrolled hemorrhage remains a persistent problem especially in anatomical areas where compression and tourniquet cannot be applied. Hemostatic agents are materials which can achieve control of bleeding in acute, life-threatening traumatic coagulopathy. In this study, we prepared biocompatible hydrogel-based hemostat crosslinked by ionizing radiation. Granules made from carboxymethyl cellulose and dressing from kappa carrageenan and polyethylene oxide were characterized by FT-IR, SEM, and gel analysis. Gamma radiation with a dose of 25 kGy was used for sterilization process. Stability studies indicate that the products remain effective with a shelf life of up to 18 months based on accelerated aging. Both hemostatic agents were demonstrated to be effective in vitro blood clotting assays showing a low blood clotting index, high platelet adhesion capacity and accelerated clotting time. Hemostat granules and dressing were also used in a femoral artery rat bleeding model where hemorrhage control was achieved in 90 s without compression and resulted in 100% survival rate after a 7 and 14-day observation.

  8. Comparison of transcutaneous contrast-enhanced ultrasound-guided injected hemostatic agents with traditional surgery treatment for liver, spleen and kidney trauma: a retrospective study.

    PubMed

    Wang, Dong; Lv, Faqin; Luo, Yukun; An, Lichun; Li, Junlai; Xie, Xia; Tian, Jiangke; Zhao, Weiyan; Tang, Jie

    2012-10-01

    There is lack of studies on the effectiveness of transcutaneous contrast-enhanced ultrasound-guided injections of hemostatic agents for liver. spleen and kidney trauma. We compared treatment by hemostatic agents to surgical treatment in a retrospective interventional human study. The study enrolled a total of 135 subjects from emergency unit of the Chinese People's Liberation Army General Hospital in Beijing. Within the cohort, 62 patients received contrast enhanced ultrasound-guided injection of hemostatic agents and the rest received surgical treatments. The injury severity score was lower in the hemostatic agent treatment group than surgical treatment group (p<0.05), but Glasgow coma scale scores did not reach statistical significance. The patients in the surgical treatment group had significantly higher hospital fees than those in the hemostatic treatment group (p<0.05), although the length of hospitalization did not significantly differ between two groups. Safety outcome variables pre- and post-treatment remained within normal limits in both groups. Hemostatic agents were more cost-effective than surgery to treat patients with liver, spleen and kidney trauma. However, given the limited sample size, subsequent studies drawing upon larger populations from multiple medical centers are necessary for follow-up.

  9. Massive transfusion and nonsurgical hemostatic agents.

    PubMed

    Perkins, Jeremy G; Cap, Andrew P; Weiss, Brendan M; Reid, Thomas J; Bolan, Charles D; Bolan, Charles E

    2008-07-01

    Hemorrhage in trauma is a significant challenge, accounting for 30% to 40% of all fatalities, second only to central nervous system injury as a cause of death. However, hemorrhagic death is the leading preventable cause of mortality in combat casualties and typically occurs within 6 to 24 hrs of injury. In cases of severe hemorrhage, massive transfusion may be required to replace more than the entire blood volume. Early prediction of massive transfusion requirements, using clinical and laboratory parameters, combined with aggressive management of hemorrhage by surgical and nonsurgical means, has significant potential to reduce early mortality. Although the classification of massive transfusion varies, the most frequently used definition is ten or more units of blood in 24 hrs. Transfusion of red blood cells is intended to restore blood volume, tissue perfusion, and oxygen-carrying capacity; platelets, plasma, and cryoprecipitate are intended to facilitate hemostasis through prevention or treatment of coagulopathy. Massive transfusion is uncommon in civilian trauma, occurring in only 1% to 3% of trauma admissions. As a result of a higher proportion of penetrating injury in combat casualties, it has occurred in approximately 8% of Operation Iraqi Freedom admissions and in as many as 16% during the Vietnam conflict. Despite its potential to reduce early mortality, massive transfusion is not without risk. It requires extensive blood-banking resources and is associated with high mortality. This review describes the clinical problems associated with massive transfusion and surveys the nonsurgical management of hemorrhage, including transfusion of blood products, use of hemostatic bandages/agents, and treatment with hemostatic medications.

  10. Hemostatic Abnormalities in Multiple Myeloma Patients

    PubMed Central

    Gogia, Aarti; Sikka, Meera; Sharma, Satender; Rusia, Usha

    2018-01-01

    Background: Multiple myeloma (MM) is a neoplastic plasma cell disorder characterized by clonal proliferation of plasma cells in the bone marrow. Diverse hemostatic abnormalities have been reported in patients with myeloma which predispose to bleeding and also thrombosis. Methods: Complete blood count, biochemical parameters and parameters of hemostasis i.e. platelet count, prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), factor VIII assay results, plasma fibrinogen, D-dimer and lupus anticoagulant, were assessed in 29 MM patients and 30 age matched controls. Results: The most frequent abnormal screening parameter was APTT. Of the six indicative of a bleeding tendency i.e. thrombocytopenia, prolonged PT, APTT, TT, reduced plasma fibrinogen and factor VIII, at least one was abnormal in 8 (27.6%) patients. Of the four prothrombotic markers, lupus anticoagulant, D-dimer, elevated factor VIII and plasma fibrinogen, one or more marker was present in 24 (82.7%). D-dimer was the most common prothrombotic marker, being elevated in 22 (75.9%) patients. One or more laboratory parameter of hemostasis was abnormal in all 29 (100%) patients. Though thrombotic complications are reported to be less frequent as compared to hemorrhagic manifestations, one or more marker of thrombosis was present in 24 (82.7%) patients. Conclusion: This study provided laboratory evidence of hemostatic dysfunction which may be associated with thrombotic or bleeding complications at diagnosis in all MM patients. Hence, screening for these abnormalities at the time of diagnosis should help improved prognosis in such cases. PMID:29373903

  11. [Hemostatic and analgesic effect of Gonghuan Zhixue Tablet on mice].

    PubMed

    Fu, Ling-Mei; You, Zhao-Ling; Lei, Lei; Wen, Le-Xi; Chen, Huan-Ming

    2004-03-01

    To explore the hemostatic and analgesic effect of Gonghuan Zhixue Tablet (GHZXT) on mice and to produce experimental evidence for exploiting new drug for endometrorrhagia caused by Cu-intrauterine contraceptive device (Cu-IUD). Compared with 6-aminocaproic acid and notoginseng, the effects of GHZXT on clotting and bleeding time of mice with capillary method and severed tail were investigated; and compared with aspirin, the analgesic effects of GHZXT on mice were investigated with hot plate and torsive body method. The clotting time of mice was remarkably shortened with a rising of the dosage of GHZXT and the difference between each therapeutic group and distilled water group was remarkable. As compared with distilled water group, the bleeding time of each dosage group of GHZXT was obviously shortened; and each dosage of GHZXT could prolong the time of pain reaction to hot plate and decrease the degree of torsive body of the mice. Pharmacological experiment has proved that GHZXT has evident hemostatic and analgesic function.

  12. Effect of aluminum chloride hemostatic agent on microleakage of class V composite resin restorations bonded with all-in-one adhesive

    PubMed Central

    Mohammadi, Narmin; Bahari, Mahmood; Pournaghi-Azar, Fatemeh; Mozafari, Aysan

    2012-01-01

    Objectives: Since hemostatic agents can induce changes on enamel and dentin surfaces and influence composite resin adhesion, the aim of the present study was to evaluate the effect of the aluminum chloride hemostatic agent on the gingival margin microleakage of class V (Cl V) composite resin restorations bonded with all-in-one adhesive. Study design: Cl V cavities were prepared on the buccal surfaces of 60 sound bovine permanent incisors. Gingival margins of the cavities were placed 1.5 mm apical to the cemento-enamel junction (CEJ). The teeth were randomly divided into two groups of 30. In group 1, the cavities were restored without the application of a hemostatic agent; in group 2, the cavities were restored after the application of the hemostatic agent. In both groups all-in-one adhesive and Z250 composite resin were used to restore the cavities with the incremental technique. After finishing and polishing, the samples underwent a thermocycling procedure, followed by immersion in 2% basic fuschin solution for 24 hours. The samples were sectioned and gingival microleakage was evaluated under a stereomicroscope. The non-parametric Mann-Whitney U test was used to compare microleakage between the two groups. Statistical significance was defined at P<0.05. Results: A statistically significant difference was observed in microleakage between the two groups (P<0.001). Conclusions: Contamination of Cl V composite resin restorations bonded with all-in-one adhesive with aluminum chloride hemostatic agent significantly increases restoration gingival margin microleakage. Key words:All-in-one adhesive resin, composite resin restoration, hemostatic agent, microleakage. PMID:22322497

  13. Structure/function relations of hemostatic nonwoven dressings based on greige cotton

    USDA-ARS?s Scientific Manuscript database

    A variety of natural and synthetic fibers are employed in hemostatic dressings. Here we demonstrate the use of greige cotton as a functional fiber, which when combined with hydrophilic and hydrophobic fibers in hydroentangled nonwoven materials, promotes accelerated clotting. A biophysical approach...

  14. Fibrin glue as a hemostatic agent in hepatic and splenic trauma.

    PubMed

    Ochsner, M G; Maniscalco-Theberge, M E; Champion, H R

    1990-07-01

    Fibrin glue is a biologic hemostatic agent that coagulates and seals upon application. It is made by combining human fibrinogen concentrate with standard thrombin solutions containing calcium. Similar to epoxy glue, the two components are applied simultaneously in equal volumes resulting in an almost instantaneous formation of a coagulum. Fibrinogen concentrate is prepared in the blood bank from single donor plasma. Fibrin glue can be applied topically or injected into the parenchyma of solid organs. Twenty-six patients sustained hepatic or splenic trauma from May through August 1989--17 liver and nine splenic injuries. The glue was effective after one application in 21 patients and after a second in five. Hemostasis was achieved despite coagulopathy and thrombocytopenia in eight patients. There were no re-explorations for bleeding, and nine complications occurred in six patients. Our experience suggests fibrin glue is an effective, underutilized adjunctive hemostatic agent in trauma.

  15. Use of absorbable hemostatic gauze with medical adhesive is effective for achieving hemostasis in presacral hemorrhage.

    PubMed

    Zhang, Chang-Hua; Song, Xin-Ming; He, Yu-Long; Han, Fanghai; Wang, Liang; Xu, Jian-Bo; Chen, Chuang-Qi; Cai, Shi-Rong; Zhan, Wen-Hua

    2012-04-01

    Management of presacral hemorrhage is always challenging. Herein we describe the use of an absorbable hemostatic gauze with α-cyanoacrylate medical adhesive to achieve hemostasis. In this study, we conducted total mesorectal excision for the treatment of rectal cancer in 258 patients from March 2006 to May 2009. Intraoperative presacral hemorrhage developed in 5 (2%) patients during rectal mobilization. In these 5 patients, massive bleeding could not be controlled by pressure and pelvic packing with gauze. An absorbable hemostatic gauze spread with medical adhesive was compressed onto the bleeding vessel for at least 20 minutes. Hemostasis was achieved successfully and was maintained during the surgery. Patients recovered uneventfully and no postoperative events were noted. The use of an absorbable hemostatic gauze with medical adhesive is a simple and effective method for achieving hemostasis when massive presacral hemorrhage occurs. However, its effectiveness needs to be confirmed in a controlled study in a properly selected patient population. Copyright © 2012. Published by Elsevier Inc.

  16. Serological analysis of patients treated with a new surgical hemostat containing bovine proteins and autologous plasma.

    PubMed

    Nelson, P A; Powers, J N; Estridge, T D; Elder, E A; Alea, A D; Sidhu, P K; Sehl, L C; DeLustro, F A

    2001-01-01

    A randomized, controlled clinical study of the management of diffuse bleeding with CoStasis surgical hemostat, a new hemostat containing bovine thrombin and collagen with the patient's own plasma, included patients undergoing cardiac, hepatic, iliac, and general surgery. Sera from 92 patients treated with CoStasis and 84 control patients were collected preoperatively and at a post surgical follow-up of 8 weeks. Among the control group, 57 patients were treated with Instat collagen sponge in noncardiac indications. Results showed that antibody responses in the CoStasis clinical study were similar to the reported literature for all antigens screened and were not associated with any adverse reactions. The bovine thrombin preparations in CoStasis and other commercially available thrombins were compared with the use of SDS-PAGE and Western blot analyses. Within this clinical study, CoStasis was shown to be a safe and effective hemostatic product containing bovine thrombin and bovine collagen and no pooled human blood products. Copyright 2001 John Wiley & Sons, Inc.

  17. Clinical, laboratory, and hemostatic findings in cats with naturally occurring sepsis.

    PubMed

    Klainbart, Sigal; Agi, Limor; Bdolah-Abram, Tali; Kelmer, Efrat; Aroch, Itamar

    2017-11-01

    OBJECTIVE To characterize clinical and laboratory findings in cats with naturally occurring sepsis, emphasizing hemostasis-related findings, and evaluate these variables for associations with patient outcomes. DESIGN Prospective, observational, clinical study. ANIMALS 31 cats with sepsis and 33 healthy control cats. PROCEDURES Data collected included history; clinical signs; results of hematologic, serum biochemical, and hemostatic tests; diagnosis; and outcome (survival vs death during hospitalization or ≤ 30 days after hospital discharge). Differences between cats with and without sepsis and associations between variables of interest and death were analyzed statistically. RESULTS The sepsis group included cats with pyothorax (n = 10), septic peritonitis (7), panleukopenia virus infection (5), bite wounds (5), abscesses and diffuse cellulitis (3), and pyometra (1). Common clinical abnormalities included dehydration (21 cats), lethargy (21), anorexia (18), pale mucous membranes (15), and dullness (15). Numerous clinicopathologic abnormalities were identified in cats with sepsis; novel findings included metarubricytosis, hypertriglyceridemia, and high circulating muscle enzyme activities. Median activated partial thromboplastin time and plasma D-dimer concentrations were significantly higher, and total protein C and antithrombin activities were significantly lower, in the sepsis group than in healthy control cats. Disseminated intravascular coagulopathy was uncommon (4/22 [18%] cats with sepsis). None of the clinicopathologic abnormalities were significantly associated with death on multivariate analysis. CONCLUSIONS AND CLINICAL RELEVANCE Cats with sepsis had multiple hematologic, biochemical, and hemostatic abnormalities on hospital admission, including several findings suggestive of hemostatic derangement. Additional research including larger numbers of cats is needed to further investigate these findings and explore associations with outcome.

  18. Normal Hemostatic Profiles and Coagulation Factors in Healthy Free-Living Florida Manatees ( Trichechus manatus latirostris).

    PubMed

    Barratclough, Ashley; Floyd, Ruth Francis; Conner, Bobbi; Reep, Roger; Ball, Ray; Stacy, Nicole

    2016-10-01

    Hemostatic disorders presumptively play an important role in the pathophysiology of several important disease conditions in the Florida manatee ( Trichechus manatus latirostris). Prior to pursuing such clinical implications, it is essential to establish normal hemostatic profiles in clinically healthy animals. During annual health assessments of free-living manatees organized by the US Geological Survey, blood samples were collected from 12 healthy animals from the Atlantic coast and 28 from the Gulf of Mexico coast of Florida, with body lengths of 210-324 cm. The following analyses were performed on citrated plasma: prothrombin (PT), partial thromboplastin time (PTT), and concentrations of fibrinogen, D-dimers, and coagulation factors VII, VIII, IX, X, XI, and XII. Compared to other mammalian species, manatees had short PT (9.2±1.5 s) and PTT (10.7±0.5 s), fibrinogen was 369±78.7 mg/dL, antithrombin III was 132±11%, and D-dimer was 142±122 ng/mL. Baseline concentrations for the listed coagulation factors were established. When comparing coagulation factors between locations, Atlantic coast manatees had significantly higher factors VIII, IX, and X than did Gulf Coast manatees. This finding may reflect differences in water salinity, diet, or genetics. There were no differences in coagulation factors when among sexes and sizes. These baselines for hemostatic profiles and coagulation factors in healthy free-living manatees lay the foundation for diagnosis and future research of hemostatic disorders and contribute to understanding their role in the pathophysiology of manatees affected by various diseases.

  19. Kaolin-based hemostatic dressing improves hemorrhage control from a penetrating inferior vena cava injury in coagulopathic swine.

    PubMed

    Koko, Kiavash R; McCauley, Brian M; Gaughan, John P; Nolan, Ryan S; Fromer, Marc W; Hagaman, Ashleigh L R; Choron, Rachel L; Brown, Spencer A; Hazelton, Joshua P

    2017-07-01

    Retrohepatic inferior vena cava (RIVC) injuries are often lethal due to challenges in obtaining hemorrhage control. We hypothesized that packing with a new kaolin-based hemostatic dressing (Control+; Z-Medica, Wallingford, CT) would improve hemorrhage control from a penetrating RIVC injury compared with packing with standard laparotomy sponges alone. Twelve male Yorkshire pigs received a 25% exchange transfusion of blood for refrigerated normal saline to induce a hypothermic coagulopathy. A laparotomy was performed and a standardized 1.5 cm injury to the RIVC was created which was followed by temporary abdominal closure and a period of uncontrolled hemorrhage. When the mean arterial pressure reached 70% of baseline, demonstrating hemorrhagic shock, the abdomen was re-entered, and the injury was treated with perihepatic packing using standard laparotomy sponges (L; n = 6) or a new kaolin-based hemostatic dressing (K; n = 6). Animals were then resuscitated for 6 hours with crystalloid solution. The two groups were compared using the Wilcoxon rank sum test and Fisher exact test. A p value of 0.05 or less was considered statistically significant. There was no difference in the animal's temperature, heart rate, mean arterial pressure, cardiac output, and blood loss at baseline or before packing was performed (all p > 0.05). In the laparotomy sponge group, five of six pigs survived the entire study period, whereas all six pigs treated with kaolin-based D2 hemostatic dressings survived. Importantly, there was significantly less blood loss after packing with the new hemostatic kaolin-based dressing compared with packing with laparotomy sponge (651 ± 180 mL vs. 1073 ± 342 mL; p ≤ 0.05). These results demonstrate that the use of this new hemostatic kaolin-based dressing improved hemorrhage control and significantly decreased blood loss in this penetrating RIVC model. This is basic science research based on a large animal model, level V.

  20. Properties of novel bone hemostat prepared using sugar-modified hydroxyapatite, phosphoryl oligosaccharides of calcium and thermoplastic resin

    NASA Astrophysics Data System (ADS)

    Mimira, Tokio; Umeda, Tomohiro; Musha, Yoshiro; Itatani, Kiyoshi

    2013-12-01

    A novel hemostatic agent was prepared using phosphoryl oligosaccharides of calcium (POs-Ca), hydroxyapatite (Ca10(PO4)6(OH)2; HAp) obtained by the hydrolysis of POs-Ca or sugar-containing HAp (s-HAp; 60.3 mass% calcium-deficient HAp and 39.5 mass% organic materials, Ca/P ratio = 1.56) and thermoplastic resin (the mixture of random copolymer of ethylene oxide/propylene oxide (EPO) and polyethylene oxide (EO); EPO : EO : water = 25 : 15 : 60 (mass ratio); 25EPO-15EO). The gel formed by mixing 25EPO-15EO with water (25EPO-15EO/water mass ratio: 0.20) was flash frozen at -80°C, freeze-dried at -50°C for 15 h and then ground using mixer. The consistency conditions of hemostats mixed with POs-Ca or s-HAp were optimized for the practical uses. The mean stanching times of hemostats were: s-HAp/25EPO-15EO (8.2 h; s-HAp/25EPO-15EO = 0.20) > 25EPO-15EO (5.3 h) > POs-Ca/25EPO-15EO (4.7 h; POs-Ca/25EPO-15EO = 0.20). The gentamicin, a typical antibiotic agent, loaded s-HAp/25EPO-15EO composite hemostat showed the steady state releasing in phosphate buffered saline till 10 h immersion at 37.0°C.

  1. Fibrin Sealant: The Only Approved Hemostat, Sealant, and Adhesive—a Laboratory and Clinical Perspective

    PubMed Central

    Spotnitz, William D.

    2014-01-01

    Background. Fibrin sealant became the first modern era material approved as a hemostat in the United States in 1998. It is the only agent presently approved as a hemostat, sealant, and adhesive by the Food and Drug Administration (FDA). The product is now supplied as patches in addition to the original liquid formulations. Both laboratory and clinical uses of fibrin sealant continue to grow. The new literature on this material also continues to proliferate rapidly (approximately 200 papers/year). Methods. An overview of current fibrin sealant products and their approved uses and a comprehensive PubMed based review of the recent literature (February 2012, through March 2013) on the laboratory and clinical use of fibrin sealant are provided. Product information is organized into sections based on a classification system for commercially available materials. Publications are presented in sections based on both laboratory research and clinical topics are listed in order of decreasing frequency. Results. Fibrin sealant remains useful hemostat, sealant, and adhesive. New formulations and applications continue to be developed. Conclusions. This agent remains clinically important with the recent introduction of new commercially available products. Fibrin sealant has multiple new uses that should result in further improvements in patient care. PMID:24729902

  2. Effectiveness of the polysaccharide hemostatic powder in non-variceal upper gastrointestinal bleeding: Using propensity score matching.

    PubMed

    Park, Jun Chul; Kim, Yeong Jin; Kim, Eun Hye; Lee, Jinae; Yang, Hyun Su; Kim, Eun Hwa; Hahn, Kyu Yeon; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan

    2018-02-07

    Recently, the application of hemostatic powder to the bleeding site has been used to treat active upper gastrointestinal bleeding (UGIB). We aimed to assess the effectiveness of the polysaccharide hemostatic powder (PHP) in patients with non-variceal UGIB. We reviewed prospectively collected 40 patients with UGIB treated with PHP therapy between April 2016 and January 2017 (PHP group) and 303 patients with UGIB treated with conventional therapy between April 2012 and October 2014 (conventional therapy group). We compared the rate of successful hemostasis and the rebleeding between the two groups after as well as before propensity score matching using the Glasgow-Blatchford score and Forrest classification. Thirty patients treated with the PHP and 60 patients treated with conventional therapy were included in the matched groups. Baseline patient characteristics including comorbidities, vital signs, and bleeding scores were similar in the matched groups. The rate of immediate hemostasis and 7-day and 30-day rebleeding were also similar in the two groups before and after matching. In the subgroup analysis, no significant differences in immediate hemostasis or rebleeding rate were noted between PHP in monotherapy and PHP combined with a conventional hemostatic method. At 30 days after the therapy, there were no significant PHP-related complications or mortality. Given its safety, the PHP proved feasible for endoscopic treatment of UGIB, having similar effectiveness as that of conventional therapy. The PHP may become a promising hemostatic method for non-variceal UGIB. © 2018 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  3. 4. GENERAL VIEW OF LAUNCH PAD B FROM LAUNCH PAD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. GENERAL VIEW OF LAUNCH PAD B FROM LAUNCH PAD A MOBILE SERVICE STRUCTURE; VIEW TO SOUTH. - Cape Canaveral Air Station, Launch Complex 17, Facility 28402, East end of Lighthouse Road, Cape Canaveral, Brevard County, FL

  4. Combination Effect of Hemostatic and Disinfecting Agents on Micro-leakage of Restorations Bonded with Different Bonding Systems

    PubMed Central

    H, Farhadpour; F, Sharafeddin; Sc, Akbarian; B, Azarian

    2016-01-01

    Statement of Problem: Hemostatic agents may affect the micro-leakage of different adhesive systems. Also, chlorhexidine has shown positive effects on micro-leakage. However, their interaction effect has not been reported yet. Objectives: To evaluate the effect of contamination with a hemostatic agent on micro-leakage of total- and self-etching adhesive systems and the effect of chlorhexidine application after the removal of the hemostatic agent. Materials and Methods: Standardized Class V cavity was prepared on each of the sixty caries free premolars at the cemento-enamel junction, with the occlusal margin located in enamel and the gingival margin in dentin. Then, the specimens were randomly divided into 6 groups (n = 10) according to hemostatic agent (H) contamination, chlorhexidine (CHX) application, and the type of adhesive systems (Adper Single Bond and Clearfil SE Bond) used. After filling the cavities with resin composite, the root apices were sealed with utility wax. Furthermore, all the surfaces, except for the restorations and 1mm from the margins, were covered with two layers of nail varnish. The teeth were immersed in a 0.5% basic fuschin dye for 24 hours, rinsed, blot-dried and sectioned longitudinally through the center of the restorations bucco- lingualy. The sections were examined using a stereomicroscope and the extension of dye penetration was analyzed according to a non-parametric scale from 0 to 3. Statistical analysis was performed using Kruskal-Wallis test and Mann-Whitney U-test. Results: While ASB group showed no micro-leakage in enamel, none of the groups showed complete elimination of micro-leakage from the dentin. Regarding micro-leakage at enamel, and dentin margins, there was no significant difference between groups 1 and 2, 1 and 3, and 2 and 3 (p > 0.05). A significantly lower micro-leakage at the enamel and dentin margins was observed in group 3, compared to group 6. No significant difference was observed between groups 4 and 5 in

  5. Teaching with iPads

    NASA Astrophysics Data System (ADS)

    Maj, Hubert

    2015-04-01

    Bilingual students in high school with bilingual units in Boguchwała have received iPads for learning English and a few subjects using CLIL (biology, basics of entrepreneurship, geography, IT and mathematics). Lessons with iPads are interesting for students for several reasons. First of all, teenagers like new technologies and using iPads for teaching helps students to learn by fun. Secondly, iPads give new possibilities of looking for knowledge about each theme. Moreover, teaching with iPads develops students' engagement. They have a chance to choose a few among over 65 000 applications for gathering and then presenting information about the lesson topic. They can easily prepare presentations, movies, cartoons, mind maps or whatever they like. Teaching students, thanks to the iPads, makes it their initiative, and the teacher can inspire them to look for the knowledge rather than disciplining pupils. But teaching with iPads is connected with many problems. For instance, there are not any examples on how to teach using these tools. It is very up-to-date technology and teachers firstly must learn the possibilities of iPads and look for new applications. It takes much time, especially at the beginning, and is difficult especially for inexperienced teachers. In addition, it is almost impossible to maintain control of the iPads for all of the students during the lesson. They can use their iPads for something unconnected with the topic of the lesson. Thirdly is lack of time - active methods (with iPads as well) are more time-consuming and it could be that they do not finish the whole program. And of course the last, but not at least, is the problem of money. Some of the applications must be paid for, and it is usually obligatory to possess a credit card. Fortunately, it is not expensive - applications usually cost a few euros and many of them are free and really good.

  6. Influence of Hemostatic Solution on Bond Strength and Physicochemical Properties of Resin Cement.

    PubMed

    Araújo, Isabela Sousa de; Prado, Célio Jesus do; Raposo, Luís Henrique Araújo; Soares, Carlos José; Zanatta, Rayssa Ferreira; Torres, Carlos Rocha Gomes; Ruggiero, Reinaldo; Silva, Gisele Rodrigues da

    2017-01-01

    The aim of this study was to evaluate the degree of conversion, color stability, chemical composition, and bond strength of a light-cured resin cement contaminated with three different hemostatic solutions. Specimens were prepared for the control (uncontaminated resin cement) and experimental groups (resin cement contaminated with one of the hemostatic solutions) according to the tests. For degree of conversion, DC (n = 5) and color analyses (n = 10), specimens (3 mm in diameter and 2 mm thick) were evaluated by Fourier transform infrared spectroscopy (FTIR) and CIELAB spectrophotometry (L*, a*, b*), respectively. For elemental chemical analysis (n = 1), specimens (2 mm thick and 6 mm in diameter) were evaluated by x-ray energy-dispersive spectroscopy (EDS). The bond strengths of the groups were assessed by the microshear test (n = 20) in a leucite-reinforced glass ceramic substrate, followed by failure mode analysis by scanning electron microscopy (SEM). The mean values, except for the elemental chemical evaluation and failure mode, were evaluated by ANOVA and Tukey's HSD test. The color stability was influenced by storage time (p<0.001) and interaction between contamination and storage time (p<0.001). Hemostop and Viscostat Clear contamination did not affect the DC, however Viscostat increased the DC. Bond strength of the resin cement to ceramic was negatively affected by the contaminants (p<0.001). Contamination by hemostatic agents affected the bond strength, degree of conversion, and color stability of the light-cured resin cement tested.

  7. Rapid hemostatic and mild polyurethane-urea foam wound dressing for promoting wound healing.

    PubMed

    Liu, Xiangyu; Niu, Yuqing; Chen, Kevin C; Chen, Shiguo

    2017-02-01

    A novel rapid hemostatic and mild polyurethane-urea foam (PUUF) wound dressing was prepared by the particle leaching method and vacuum freeze-drying method using 4, 4-Methylenebis(cyclohexyl isocyanate), 4,4-diaminodicyclohexylmethane and poly (ethylene glycol) as raw materials. And X-ray diffraction (XRD), tensile test, differential scanning calorimetry (DSC) and thermogravimetry (TG) were used to its crystallinity, stress and strain behavior, and thermal properties, respectively. Platelet adhesion, fibrinogen adhesion and blood clotting were performed to evaluate its hemostatic effect. And H&E staining and Masson Trichrome staining were used to its wound healing efficacy. The results revealed the pore size of PUUF is 50-130μm, and its porosity is 71.01%. Porous PUUF exhibited good water uptake that was benefit to adsorb abundant wound exudates to build a regional moist environment beneficial for wound healing. The PUUF wound dressing exhibit better blood coagulation effect than commercial polyurethane dressing (CaduMedi). Though both PUUF and CaduMedi facilitated wound healing generating full re-epithelialization within 13days, PUUF was milder and lead to more slight inflammatory response than CaduMedi. In addition, PUUF wound dressing exhibited lower cytotoxicity than CaduMedi against NIH3T3 cells. Overall, porous PUUF represents a novel mild wound dressing with excellent water uptake, hemostatic effect and low toxicity, and it can promote wound healing and enhance re-epithelialization. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Coagulopathy and traumatic shock: Characterizing hemostatic function during the critical period prior to fluid resuscitation

    PubMed Central

    White, Nathan J.; Martin, Erika J.; Brophy, Donald F.; Ward, Kevin R.

    2009-01-01

    Aims Identifying early changes in hemostatic clot function as a result of tissue injury and hypoperfusion may provide important information regarding the mechanisms of traumatic coagulopathy. A combat-relevant swine model was used to investigate the development of coagulopathy during trauma by monitoring hemostatic function during increasing severity of shock. Methods Swine were injured (soft tissue + femur fracture) and hemorrhaged while continuously monitoring Oxygen Debt (OD) by indirect calorimetry at the airway. Hemostatic function was assessed by Thrombelastography (TEG), prothrombin time (PT), partial Thromboplastin time (PTT), and fibrinogen concentration and compared before hemorrhage (D0) and during shock when OD= 40 and 80 ml/kg. An instrumented sham group was used for comparison. Results N=23 swine (n=18 hemorrhage, n=5 sham) weighing 45+/−6 Kg were studied after removing an average of 34+/−14% of blood volume during hemorrhage. Hgb, Hct, platelet counts, PT and PTT did not change with increasing OD (p>0.05). Fibrinogen was reduced significantly by OD=40 ml/kg (mean diff =−59.9 mg/dl, 95% CI diff [−95.1, −24.6]). TEG parameters representing clot initiation (R) and polymerization (K and Alpha Angle) did not change with increasing OD during shock (p>0.053). Clot strength (MA) was reduced in the hemorrhage group by OD=80 ml/kg (mean diff = −4.1 mm, 95% CI diff [−7.4, −0.8]). Conclusion In this swine model of traumatic shock, fibrinogen was significantly reduced and an isolated reduction in clot strength (MA) was found with increasing OD. Fibrinogen consumption and altered platelet function may account for the earliest changes in hemostatic function during traumatic shock. PMID:19854556

  9. Intraoperative anaphylaxis to gelatin in topical hemostatic agents during anterior spinal fusion: a case report.

    PubMed

    Spencer, Hillard T; Hsu, Joyce T; McDonald, Douglas R; Karlin, Lawrence I

    2012-08-01

    The use of topical hemostatic agents is widespread and has been shown to reduce bleeding during a wide variety of surgical procedures. Nonetheless, as biologically active agents, there is potential for allergic reactions to these products. This is a report of intraoperative anaphylaxis to gelatin associated with the use of two topical hemostatic agents. Case report. There is no outside funding or potential conflict of interest. A patient with anaphylaxis during anterior spinal fusion. Laboratory assays for tryptase, gelatin-specific immunoglobulin E (IgE), and total IgE. A 14-year-old male with myelomeningocele and scoliosis was treated with anterior spinal fusion from T12 to L3. Gelfoam sponges were applied during the preparation of the disc spaces. Approximately 1 hour later, Floseal hemostatic matrix was applied to a briskly bleeding screw hole in the L3 vertebral body, and the patient experienced an abrupt onset of hypotension and ventilatory difficulty. Epinephrine, dexamethasone, and blood products were administered for hemodynamic support while the surgical site was closed. Removal of the drapes revealed a widespread erythematous rash, and the patient was then transferred to the intensive care unit. When stable 3 days later, he returned to the operating room for completion of the spinal fusion. Postoperative laboratory assays were sent that revealed elevated levels of tryptase, total IgE, porcine, and bovine gelatin-specific IgE. The patient was counseled to avoid gelatin-containing products. At 6-month follow-up, his instrumented spine was radiographically fused and he reported no further allergic issues. Anaphylaxis may occur because of animal gelatin components of topical hemostatic agents. Previous reports have focused on the thrombin components. Care should be taken in the administration of these products, particularly in the atopic individual. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Method of manufacturing fibrous hemostatic bandages

    DOEpatents

    Larsen, Gustavo; Spretz, Ruben; Velarde-Ortiz, Raffet

    2012-09-04

    A method of manufacturing a sturdy and pliable fibrous hemostatic dressing by making fibers that maximally expose surface area per unit weight of active ingredients as a means for aiding in the clot forming process and as a means of minimizing waste of active ingredients. The method uses a rotating object to spin off a liquid biocompatible fiber precursor, which is added at its center. Fibers formed then deposit on a collector located at a distance from the rotating object creating a fiber layer on the collector. An electrical potential difference is maintained between the rotating disk and the collector. Then, a liquid procoagulation species is introduced at the center of the rotating disk such that it spins off the rotating disk and coats the fibers.

  11. Pads and Tampons

    MedlinePlus

    ... decide which is right for you. Light or Heavy Flow? Pads come in different sizes for heavier ... not menstruating much. Naturally, if your period is heavy, you should change pads more often because they ...

  12. Hemostatic Agents in Periapical Surgery: A Randomized Study of Gauze Impregnated in Epinephrine versus Aluminum Chloride.

    PubMed

    Menéndez-Nieto, Isabel; Cervera-Ballester, Juan; Maestre-Ferrín, Laura; Blaya-Tárraga, Juan Antonio; Peñarrocha-Oltra, David; Peñarrocha-Diago, Miguel

    2016-11-01

    Adequate bleeding control is essential for the success of periapical surgery. The aim of this study was to evaluate the effects of 2 hemostatic agents on the outcome of periapical surgery and their relationship with patient and teeth parameters. A prospective study was designed with 2 randomized parallel groups, depending on the hemostatic agent used: gauze impregnated in epinephrine (epinephrine group) and aluminum chloride (aluminum chloride group). The analysis of the hemorrhage control was judged before and after the application of the hemostatic agents by the surgeon, and 2 examiners independently recorded it as adequate (complete hemorrhage control) or inadequate (incomplete hemorrhage control). Ninety-nine patients with a periradicular lesion were enrolled in this study and divided into 2 groups: gauze impregnated in epinephrine in 48 patients (epinephrine group) or aluminum chloride in 51 (aluminum chloride group). In epinephrine group adequate hemostasis was achieved in 25 cases, and in aluminum chloride group it was achieved in 37 cases (P < .05). The outcome was better in the aluminum chloride group than in the gauze impregnated in epinephrine group. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  13. Management of External Hemorrhage in Tactical Combat Casualty Care: Chitosan-Based Hemostatic Gauze Dressings--TCCC Guidelines-Change 13-05.

    PubMed

    Bennett, Brad L; Littlejohn, Lanny F; Kheirabadi, Bijan S; Butler, Frank K; Kotwal, Russ S; Dubick, Michael A; Bailey, Jeffrey A

    2014-01-01

    Hemorrhage remains the leading cause of combat death and a major cause of death from potentially survivable injuries. Great strides have been made in controlling extremity hemorrhage with tourniquets, but not all injuries are amenable to tourniquet application. Topical hemostatic agents and dressings have also contributed to success in controlling extremity and compressible junctional hemorrhage, and their efficacy continues to increase as enhanced products are developed. Since the addition of Combat Gauze™ (Z-Medica Corporation, Wallingford, CT, USA; http://www.z-medica.com/) in April 2008 to the Tactical Combat Casualty Care (TCCC) Guidelines, there are consistent data from animal studies of severe hemorrhage that chitosan-based hemostatic gauze dressings developed for battlefield application are, at least, equally efficacious as Combat Gauze. Successful outcomes are also reported using newer chitosan-based dressings in civilian hospital-based surgical case reports and prehospital (battlefield) case reports and series. Additionally, there have been no noted complications or safety concerns in these cases or across many years of chitosan-based hemostatic dressing use in both the military and civilian prehospital sectors. Consequently, after a decade of clinical use, there is added benefit and a good safety record for using chitosan-based gauze dressings. For these reasons, many specific US military Special Operations Forces, NATO militaries, and emergency medical services (EMS) and law enforcement agencies have already implemented the widespread use of these new recommended chitosan-based hemostatic dressings. Based on the past battlefield success, this report proposes to keep Combat Gauze as the hemostatic dressing of choice along with the new addition of Celox™ Gauze (Medtrade Products Ltd., Crewe, UK; http://www.celoxmedical.com/usa/products /celox-gauze/) and ChitoGauze® (HemCon Medical Technologies, Portland, OR, USA; http://www.hemcon.com/) to the TCCC

  14. PAD_AUDIT -- PAD Auditing Package

    NASA Astrophysics Data System (ADS)

    Clayton, C. A.

    The PAD (Packet Assembler Disassembler) utility is the part of the VAX/VMS Coloured Book Software (CBS) which allows a user to log onto remote computers from a local VAX. Unfortunately, logging into a computer via either the Packet SwitchStream (PSS) or the International Packet SwitchStream (IPSS) costs real money. Some users either do not appreciate this or do not care and have been known to clock up rather large quarterly bills. This software package allows a system manager to determine who has used PAD to call where and (most importantly) how much it has cost. The system manager can then take appropriate action - either charging the individuals, warning them to use the facility with more care or even denying access to a greedy user to one or more sites.

  15. Evaluation of FloSeal as a Potential Intracavitary Hemostatic Agent

    DTIC Science & Technology

    2006-02-01

    Laws ER Jr. Use of FloSeal hemostatic sealant in transsphenoidal pituitary surgery : technical note. Neurosurgery. 2002;51:513–516. 14. Kheirabadi BS...of death in com- bat and civilian trauma. When surgery is unavailable, one potential solution to such hemorrhage might be the introduction of an agent...situations, including venous and arterial vascular surgery ,7,9 cardiac valve replacement or cardiopulmonary bypass grafting,6 partial nephrectomies,10

  16. Effects of Contamination by Hemostatic Agents and Use of Cleaning Agent on Etch-and-Rinse Dentin Bond Strength.

    PubMed

    Pucci, César Rogério; Araújo, Rodrigo Maximo de; Lacerda, Ana Julia Farias de; Souza, Mirella Anjos de; Huhtala, Maria Filomena Rocha Lima; Feitosa, Fernanda Alves

    2016-01-01

    The aim of this study was to evaluate the influence of contamination by hemostatic agents and rinsing with chlorhexidine on bond strength between dentin and resin composite. Ninety-six bovine teeth were sectioned to expose a flat dentin surface area. A standardized cavity with 2.0 mm in thickness, superficial diameter of 4.0 mm and bottom diameter of 3.0 mm was prepared with a diamond bur in each dentin specimen. The teeth were divided into four groups according to the hemostatic employed: G1: control; G2: use of ViscoStat, Ultradent; G3: Hemosthasegel, FGM; and G4: Hemostop, Dentsply. The groups were divided into two subgroups according to the cleaning protocol method (n=12): A: without any further cleaning; and B: cleaning with chlorhexidine at 0.2%. All cavities were filled using a dentin adhesive and a resin composite, following the manufacturer's instructions. After 24 h, the specimens were aged by thermal and mechanical cycling. The bond strength was determined by the push out bond test (MPa), Statistical analysis was performed using two-way ANOVA and Tukey test (p<0.05). Statistically significant differences were detected among all groups treated with hemostatic agents and the control group. The post-hoc test showed that cleaning the cavity with chlorhexidine significantly improves the bond strength between dentin and resin composite. Our results suggested that the use of chlorhexidine can reestablish the bond strength between dentin and resin composite when a hemostatic agent was applied.

  17. Abdominal wall fat pad biopsy

    MedlinePlus

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  18. Emerging roles for hemostatic dysfunction in malaria pathogenesis.

    PubMed

    O'Sullivan, Jamie M; Preston, Roger J S; O'Regan, Niamh; O'Donnell, James S

    2016-05-12

    Severe Plasmodium falciparum malaria remains a leading cause of mortality, particularly in sub-Saharan Africa where it accounts for up to 1 million deaths per annum. In spite of the significant mortality and morbidity associated with cerebral malaria (CM), the molecular mechanisms involved in the pathophysiology of severe malaria remain surprisingly poorly understood. Previous studies have demonstrated that sequestration of P falciparum-infected erythrocytes within the microvasculature of the brain plays a key role in the development of CM. In addition, there is convincing evidence that both endothelial cell activation and platelets play critical roles in the modulating the pathogenesis of severe P falciparum malaria. In this review, we provide an overview of recent studies that have identified novel roles through which hemostatic dysfunction may directly influence malaria pathogenesis. In particular, we focus on emerging data suggesting that von Willebrand factor, coagulation cascade activation, and dysfunction of the protein C pathway may be of specific importance in this context. These collective insights underscore a growing appreciation of the important, but poorly understood, role of hemostatic dysfunction in malaria progression and, importantly, illuminate potential approaches for novel therapeutic strategies. Given that the mortality rate associated with CM remains on the order of 20% despite the availability of effective antimalarial therapy, development of adjunctive therapies that can attenuate CM progression clearly represents a major unmet need. These emerging data are thus not only of basic scientific interest, but also of direct clinical significance. © 2016 by The American Society of Hematology.

  19. Hemostatic bioactivity of novel Pollen Typhae Carbonisata-derived carbon quantum dots.

    PubMed

    Yan, Xin; Zhao, Yan; Luo, Juan; Xiong, Wei; Liu, Xiaoman; Cheng, Jinjun; Wang, Yongzhi; Zhang, Meiling; Qu, Huihua

    2017-09-05

    Pollen Typhae Carbonisata (PTC) is a type of calcined herb drug that has been used as a hemostatic medicine to promote hemostasis for thousands of years. In this study, we discovered and separated novel water-soluble carbon quantum dots (CQDs, named PTC-CQDs) from aqueous extracts of PTC. These PTC-CDs were characterized using transmission electron microscopy (TEM) and high-resolution TEM, as well as Fourier transform infrared, ultraviolet-visible, and fluorescence spectroscopy. Then, we assessed the anti-hemorrhagic effects and related hemostatic mechanisms of the obtained PTC-CQDs. The PTC-CQDs separated from PTC are spherical, monodisperse, and have a narrow size distribution between 2 and 8 nm. In the pharmacology experiment, remarkable anti-hemorrhage effects of PTC-CQDs were revealed. Additionally, the rats showed a profound decrease in activated partial thromboplastin time and increase in fibrinogen and PLT after PTC-CQDs treatment. These results indicated the explicit hemostasis effect of PTC-CQDs, which not only provided a new idea for the material research of PTC, but have also provided new insights into potential biomedical and healthcare applications of CQDs in the field of haemorrhage control and laid a solid foundation for future drug discovery.

  20. Hemostatic gauze based on chitosan and hydroquinone: preparation, characterization and blood coagulation evaluation.

    PubMed

    Cassano, Roberta; Di Gioia, Maria Luisa; Mellace, Silvia; Picci, Nevio; Trombino, Sonia

    2017-11-07

    This work concerns on the preparation and performance evaluation of a new chitosan hydroquinone based gauze for hemostatic use. Chitosan and hydroquinone were firstly connected by etherification and then linked to the pre-carboxylate gauze. The functionalized material and the chitosan-hydroquinone ether were characterized by Fourier Transform Infrared (FT-IR) Spectroscopy and Differential Scanning Calorimetry (DSC). FT-IR results showed that an esterification occurred on carboxylic group of the gauze. The gauze functionalization degree was also evaluated by volumetric analysis. The ether hydroquinone content was obtained by the Folin test. Moreover, the linkage between hydroquinone and chitosan was confirmed by nuclear magnetic resonance (NMR). The hemostatic activity of functionalized gauze was evaluated by dynamic blood clotting assays. The obtained results showed that the prepared material can shorten the blood clotting time and induce the adhesion and activation of platelets. Finally, swelling characteristic of the new gauze was evaluated to confirm its high capacity to absorb the blood.

  1. Dynamic behavior of air lubricated pivoted-pad journal-bearing, rotor system. 2: Pivot consideration and pad mass

    NASA Technical Reports Server (NTRS)

    Nemeth, Z. N.

    1972-01-01

    Rotor bearing dynamic tests were conducted with tilting-pad journal bearings having three different pad masses and two different pivot geometries. The rotor was vertically mounted and supported by two three-pad tilting-pad gas journal bearings and a simple externally pressurized thrust bearing. The bearing pads were 5.1 cm (2.02 in.) in diameter and 2.8 cm (1.5 in.) long. The length to diameter ratio was 0.75. One pad was mounted on a flexible diaphragm. The bearing supply pressure ranged from 0 to 690 kilonewtons per square meter (0 to 100 psig), and speeds ranged to 38,500 rpm. Heavy mass pad tilting-pad assemblies produced three rotor-bearing resonances above the first two rotor critical speeds. Lower supply pressure eliminated the resonances. The resonances were oriented primarily in the direction normal to the diaphragm.

  2. Epidural spinal cord compression with neurologic deficit associated with intrapedicular application of hemostatic gelatin matrix during pedicle screw insertion.

    PubMed

    Buchowski, Jacob M; Bridwell, Keith H; Lenke, Lawrence G; Good, Christopher R

    2009-06-01

    Case report. In order to demonstrate the dangers of intrapedicular application of a hemostatic gelatin matrix to decrease blood loss during pedicle screw insertion, we present 2 patients who--as a result of inadvertent extravasation of the matrix into the spinal canal--developed epidural spinal cord compression (ESCC) requiring emergent decompression. Variety of hemostatic agents can control bleeding during pedicle screw insertion. We have often used a hemostatic gelatin matrix to decrease bleeding from cannulated pedicles by injecting the material into the pedicle after manually palpating the pedicle. Medical records and radiographic studies of 2 patients with AIS who underwent surgical treatment of their deformity and developed a neurologic deficit due to extravasation of FloSeal were reviewed. A 15 year-old male underwent T4 to L2 posterior spinal fusion (PSF). During pedicle screw insertion, a change in NMEPs and SSEPs was noted. A wake-up test confirmed bilateral LE paraplegia. Screws were removed and no perforations were noted on manual palpation. MRI showed T7 to T10 ESCC. He underwent a T5 to T10 laminectomy and hemostatic gelatin matrix noted in the canal and was evacuated. He was ambulatory at 2 weeks and by 3 months he had complete recovery. The second patient was a 15 year-old female who underwent T4 to L1 PSF. Following screw insertion, deterioration in NMEPs and SSEPs was noted. Screws were removed and SCM data returned to baseline. Except for 3 screws that had an inferior breach (Left T7 and Bilateral T8), screws were reinserted and remainder of the surgery was uneventful. Postoperative examination was normal initially but 2 days later, she developed left LE numbness/weakness. Implants were removed and MRI showed T4 to T9 ESCC.She underwent a left (concave) T4 to T9 hemilaminectomy. Hemostatic gelatin matrix was noted and was evacuated. Six weeks following surgery, she had a complete neurologic recovery. The use of a hemostatic gelatin matrix to

  3. Comparison of hemostatic properties between collagen and synthetic buttress materials used in staple line reinforcement in a swine splenic hemorrhage model.

    PubMed

    Spector, David; Perry, Zvi; Konobeck, Tracy; Mooradian, Daniel; Shikora, Scott

    2011-04-01

    The use of staplers in gastrointestinal surgery is widespread, especially in advanced laparoscopic procedures. Staple line reinforcement with a buttress reduces bleeding and associated complications through a combination of factors. The intrinsic hemostatic properties of buttress materials have not been examined. This study examined the intrinsic hemostatic properties of two different types of material used in buttressing in an accepted hemostasis model that does not involve stapling or its effects by compression. An acellular collagen buttress (Veritas) and a synthetic polymer buttress (Duet) were compared to two commonly used hemostatic agents, Syvek and Surgicel, with gauze as control. In a swine capsular stripping hemostasis model, a 1 × 1 cm section of spleen capsule was removed and used as a source of bleeding, with one patch of material tested per bleeding site. A total of 51 wounds were created in five pigs (each patch n = 10, control n = 11). Hemostatic efficacy was assessed by quantitating the number of applications and total time needed for bleeding to stop. The mean time needed for hemostasis for Syvek and Veritas patches was significantly less than gauze, Duet and Surgicel (4.02, 4.51 vs. 8.97, 9.22, and 10.30 min respectively; p < 0.05). The Syvek and Veritas patches required significantly fewer applications than gauze, Duet™ and Surgicel (1.7, 2.2 vs. 4.1, 4.6, and 4.9 respectively; p < 0.01). The intrinsic hemostatic properties of different buttressing materials vary widely. In this study, a collagen buttress was significantly better at promoting hemostasis than the synthetic buttress material in a nonstapling model. This could be another factor to consider when choosing a buttress for staple line reinforcement.

  4. Hemostatic Effects of Microbubble-Enhanced Low-Intensity Ultrasound in a Liver Avulsion Injury Model

    PubMed Central

    Feng, Guiying; Liu, Jianhua; Zhao, Xiaochen; Wei, Jinglu; Ou, Wencai; Xiao, Shuyi; Hu, Zhiwen; Wei, Hongqin; Liu, Zheng

    2014-01-01

    Objectives Microbubble-enhanced therapeutic ultrasound (MEUS) can block the blood flow in the organs. The aim of this study was to evaluate the hemostatic effect of microbubble-enhanced pulsed, low-intensity ultrasound in a New Zealand White rabbit model of avulsion trauma of the liver. The therapeutic ultrasound (TUS) transducer was operated with the frequency of 1.2 MHz and an acoustic pressure of 3.4 MPa. Microbubble-(MB) enhanced ultrasound (MEUS) (n = 6) was delivered to the distal part of the liver where the avulsion was created. Livers were treated by TUS only (n = 4) or MB only (n = 4) which served as controls. Bleeding rates were measured and contrast enhanced ultrasound (CEUS) was performed to assess the hemostatic effect, and liver hemoperfusion before and after treatment. Generally, bleeding rates decreased more than 10-fold after the treatment with MEUS compared with those of the control group (P<0.05). CEUS showed significant declines in perfusion. The peak intensity value and the area under the curve also decreased after insonation compared with those of the control group (P<0.05). Histological examination showed cloudy and swollen hepatocytes, dilated hepatic sinusoids, perisinusoidal spaces with erythrocyte accumulation in small blood vessels, obvious hemorrhage around portal areas and scattered necrosis in liver tissues within the insonation area of MEUS Group. In addition, necrosis was found in liver tissue 48 h after insonation. We conclude that MEUS might provide an effective hemostatic therapy for serious organ trauma such as liver avulsion injury. PMID:24788757

  5. Exploring the Urtica dioica Leaves Hemostatic and Wound-Healing Potential.

    PubMed

    Zouari Bouassida, Karama; Bardaa, Sana; Khimiri, Meriem; Rebaii, Tarek; Tounsi, Slim; Jlaiel, Lobna; Trigui, Mohamed

    2017-01-01

    The present paper investigated the efficiency of Urtica dioica (U. dioica) on hemostatic and wound healing activities. U. dioica leaf extracts were evaluated for their antibacterial and antioxidant effects as well as their flavonoid and polyphenol content. The hydroethanolic extract (EtOH-H 2 OE), showing the most potent antibacterial and antioxidant activities in vitro , thanks to its flavonoid and polyphenol richness, was selected for hemostatic and wound healing evaluation. Twenty-four rats completing full-thickness wounds were split into four groups. The wounds were topically treated with saline solution, glycerol, "CICAFLORA," and U. dioica EtOH-H 2 OE (50  µ L/mm 2 ) until day 11. The wound healing effect was assessed by macroscopic, histological, and biochemical parameters. Rats treated with EtOH-H 2 OE showed fast wound closure (92.39%) compared to the control animals (60.91%) on the 11th day of wounding ( P < 0.01). Histopathological and biochemical explorations showed full epidermal regeneration and an improvement of the hydroxyproline content in the U. dioica EtOH-H 2 OE treated rats. Analysis of fatty acids and sterols by GC-MS showed the presence of unsaturated fatty acids and a high concentration of lupeol known for their involvement in reepithelialization. These results prove the efficiency of U. dioica EtOH-H 2 OE in wound healing and supported its traditional use.

  6. Exploring the Urtica dioica Leaves Hemostatic and Wound-Healing Potential

    PubMed Central

    Bardaa, Sana; Khimiri, Meriem; Rebaii, Tarek; Jlaiel, Lobna

    2017-01-01

    The present paper investigated the efficiency of Urtica dioica (U. dioica) on hemostatic and wound healing activities. U. dioica leaf extracts were evaluated for their antibacterial and antioxidant effects as well as their flavonoid and polyphenol content. The hydroethanolic extract (EtOH-H2OE), showing the most potent antibacterial and antioxidant activities in vitro, thanks to its flavonoid and polyphenol richness, was selected for hemostatic and wound healing evaluation. Twenty-four rats completing full-thickness wounds were split into four groups. The wounds were topically treated with saline solution, glycerol, “CICAFLORA,” and U. dioica EtOH-H2OE (50 µL/mm2) until day 11. The wound healing effect was assessed by macroscopic, histological, and biochemical parameters. Rats treated with EtOH-H2OE showed fast wound closure (92.39%) compared to the control animals (60.91%) on the 11th day of wounding (P < 0.01). Histopathological and biochemical explorations showed full epidermal regeneration and an improvement of the hydroxyproline content in the U. dioica EtOH-H2OE treated rats. Analysis of fatty acids and sterols by GC-MS showed the presence of unsaturated fatty acids and a high concentration of lupeol known for their involvement in reepithelialization. These results prove the efficiency of U. dioica EtOH-H2OE in wound healing and supported its traditional use. PMID:29201895

  7. The PICS Technique: A Novel Approach for Residual Curvature Correction During Penile Prosthesis Implantation in Patients With Severe Peyronie's Disease Using the Collagen Fleece TachoSil.

    PubMed

    Hatzichristodoulou, Georgios

    2018-03-01

    Correction of residual curvature during inflatable penile prosthesis (IPP) implantation in patients with Peyronie's disease (PD) by plaque incision and grafting is a common approach. To present a novel technique for residual curvature correction during IPP implantation using collagen fleece (TachoSil, Baxter Healthcare Corp, Deerfield, IL, USA). After the IPP (Titan Touch, Coloplast, Minneapolis, MN, USA) is placed, the implant is inflated maximally. When residual curvature exceeds 40°, the PICS (penile implant in combination with the Sealing technique) technique is performed. The device is deflated, and a circumcising skin incision and penile degloving are performed. After elevation of the neurovascular bundle, the device is reinflated maximally. Plaque incision is performed at the point of maximum curvature using electrocautery. This leads to penile straightening because the tension is removed. In the next step, the defect of the tunica is closed with collagen fleece, which sticks to the tunica and defect without any sutures needed. The neurovascular bundle is reapproximated and the Buck fascia is closed. This is followed by closure of penile skin. Primary outcome measurements were straightening rates, operative times, 5-item International Index of Erectile Function (IIEF-5) scores at follow-up, immediate and late complications, and patient satisfaction. The PICS technique was applied to 15 patients. Mean patient age was 61.7 years (52-79 years). Mean residual curvature after IPP was 66.7° (50-90°). Mean operative time was 117.3 minutes (100-140 minutes). Mean follow-up was 15.1 months (1-29 months). 12 of 15 patients (80%) showed a totally straight penis. 3 patients (20%) had residual curvature of 10° at follow-up, which did not interfere with sexual intercourse. Mean IIEF-5 score at follow-up was 24.2 (22-25). No immediate or late complications occurred. All patients were satisfied with the surgical outcomes. This novel technique prevents puncture or

  8. Treating P.A.D.

    MedlinePlus

    ... Issue Past Issues Special Section Treating P.A.D. Past Issues / Summer 2008 Table of Contents For ... Illustration courtesy of NHLBI Treatment for P.A.D. is designed to reduce a patient's symptoms, prevent ...

  9. Dual-Mode Adhesive Pad

    NASA Technical Reports Server (NTRS)

    Hartz, Leslie

    1994-01-01

    Tool helps worker grip and move along large, smooth structure with no handgrips or footholds. Adheres to surface but easily released by actuating simple mechanism. Includes handle and segmented contact-adhesive pad. Bulk of pad made of soft plastic foam conforming to surface of structure. Each segment reinforced with rib. In sticking mode, ribs braced by side catches. In peeling mode, side catches retracted, and segmented adhesive pad loses its stiffness. Modified versions useful in inspecting hulls of ships and scaling walls in rescue operations.

  10. Monopolar soft-mode coagulation using hemostatic forceps for peptic ulcer bleeding.

    PubMed

    Yamasaki, Yasushi; Takenaka, Ryuta; Nunoue, Tomokazu; Kono, Yoshiyasu; Takemoto, Koji; Taira, Akihiko; Tsugeno, Hirofumi; Fujiki, Shigeatsu

    2014-01-01

    Upper gastrointestinal hemorrhage from bleeding peptic ulcer is sometimes difficult to treat by conventional endoscopic methods. Recently, monopolar electrocoagulation using a soft-coagulation system and hemostatic forceps (soft coagulation) has been used to prevent bleeding during endoscopic submucosal dissection. The aim of this study was to assess the safety and efficacy of soft coagulation in the treatment of bleeding peptic ulcer. A total of 39 patients with peptic ulcers were treated using soft coagulation at our hospital between January 2005 and March 2010. Emergency treatment employed an ERBE soft-mode coagulation system using hemostatic forceps. Second-look endoscopy was performed to evaluate the efficacy of prior therapy. Initial hemostasis was defined as accomplished by soft coagulation, with or without other endoscopic therapy prior to soft coagulation. The rate of initial hemostasis, rebleeding, and ultimate hemostasis were retrospectively analyzed. The study subjects were 31 men and 8 women with a mean age of 68.3±13.7 years, with 29 gastric ulcers and 10 duodenal ulcers. Initial hemostasis was achieved in 37 patients (95%). During follow-up, bleeding recurred in two patients, who were retreated with soft coagulation. The monopolar soft coagulation is feasible and safe for treating bleeding peptic ulcers.

  11. Evaluation of Shear Bond Strength of Total- and Self-etching Adhesive Systems after Application of Chlorhexidine to Dentin Contaminated with a Hemostatic Agent

    PubMed Central

    Sharafeddin, Farahnaz; Farhadpour, Hajar

    2015-01-01

    Statement of the Problem Hemostatic agents may influence the bond strength of different bonding agents. Also, chlorhexidine has shown positive effects on bond strength values and their combination effect has not been reported yet. Purpose The aim of this study was to evaluate the effect of contamination with a hemostatic agent on shear bond strength (SBS) of total- and self-etching adhesive systems and the effect of chlorhexidine application after removal of the hemostatic agent. Materials and Method In this experimental study, the occlusal enamel of each sixty caries-free mandibular molars was removed and their midcoronal dentin was exposed. The specimens were then mounted in auto-polymerizing resin 1mm apical to CEJ. Then, the specimens were divided into 6 groups (n=10) based on contamination with a hemostatic agent (H), application of chlorhexidine (CHX) and the adhesive system used; and then were classified as Group 1: Adper Single Bond (ASB); Group 2: H+ASB; Group 3: H+0.2% CHX+ASB; Group 4: Clearfil SE Bond (CSB); Group 5: H+CSB; Group 6: H+0.2% CHX+CSB. Then, composite resin rods (4×2 mm) were built up on the dentin surfaces and after thermocycling, the SBS (MPa) was evaluated. Statistical analysis was performed using two-way ANOVA and post hoc Tukey tests (p< 0.05). Results There were statistically significant differences between bond strength values of group 1 (ASB) and group 2 (H+ASB) (p< 0.001) and group 1 (ASB) and group 3 (H+CHX+ASB) (p< 0.001). Similarly, significant differences were seen between group 4 (CSB) and group 5 (H+CSB) (p< 0.001) and between group 4 (CSB) and group 6 (H+CHX+CSB) (p< 0.001). Conclusion Contamination with hemostatic agent reduced the SBS of both total- and self-etching adhesive systems. In addition, application of chlorhexidine after the removal of hemostatic agent had a negative effect on SBS of total- and self-etching adhesive systems. PMID:26331146

  12. Release abilities of adenosine diphosphate from phospholipid vesicles with different membrane properties and their hemostatic effects as a platelet substitute.

    PubMed

    Okamura, Yosuke; Katsuno, Shunsuke; Suzuki, Hidenori; Maruyama, Hitomi; Handa, Makoto; Ikeda, Yasuo; Takeoka, Shinji

    2010-12-20

    We have constructed phospholipid vesicles with hemostatic activity as a platelet substitute. The vesicles were conjugated with a dodecapeptide (HHLGGAKQAGDV, H12), which is a fibrinogen γ-chain carboxy-terminal sequence (γ400-411). We have recently exploited these vesicles as a potential drug delivery system by encapsulation of adenosine 5'-diphosphate (ADP) (H12-(ADP)-vesicles). Here we explore the relationship between the ADP release from H12-(ADP)-vesicles with different membrane properties and their hemostatic effects. In total, we prepared five kinds of H12-(ADP)-vesicles with different lamellarities and membrane flexibilities. By radioisotope-labeling, we directly show that H12-(ADP)-vesicles were capable of augmenting platelet aggregation by releasing ADP in an aggregation-dependent manner. The amount of ADP released from the vesicles was dependent on their membrane properties. Specifically, the amount of ADP released increased with decreasing lamellarity and tended to increase with increasing membrane flexibility. Our in vivo results clearly demonstrated that H12-(ADP)-vesicles with the ability to release ADP exert considerable hemostatic action in terms of correcting prolonged bleeding time in a busulphan-induced thrombocytopenic rat model. We propose a recipe to control the hemostatic abilities of H12-(ADP)-vesicles by modulating ADP release based on membrane properties. We believe that this concept will be invaluable to the development of platelet substitutes and other drug carriers. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. [Use of "NovoSeven" (rFVIIa) hemostatic in patients operated with extracorporeal blood circulation].

    PubMed

    Dement'eva, I I; Sandrikov, V A; Charnaia, M A; Morozov, Iu A; Trekova, N A; Eremenko, A A

    2004-01-01

    The "NovoSeven" drug was used in 25 patients (male - 18, female - 7) operated on the heart and main vessels including with artificial extracorporeal circulation (AEC). Patients did not have any clinically significant impairment in blood circulation before surgery. Perioperatively, all of them and, immediately after surgery, 4 them had uncontrollable hemorrhages at 10-25 ml/min in spite of extensive hemostatic therapy, including freshly frozen plasma, cryoprecipitate, thromboconcentrate, trasilol and ?-amine acid. Yet in 30 min after "NovoSeven" administration, hemorrhages seized virtually in all patients irrespective of a surgical intervention. It normalized the hemostasis by it differential action on an impairment depending on an activated or suppressed coagulation. Thus, the conclusion is that the "NovoSeven" (rFVIIa) is an effective hemostatic ensuring the correction of massive intra- and postoperative blood losses in cardiosurgery patients. The drug cuts the need in using the donor-blood components, thus, diminishing the risk of multi organ failure that can develop immediately after surgery.

  14. Free radical activity and hemostatic factors in NIDDM patients with and without microalbuminuria.

    PubMed

    Collier, A; Rumley, A; Rumley, A G; Paterson, J R; Leach, J P; Lowe, G D; Small, M

    1992-08-01

    In non-insulin-dependent diabetes mellitus (NIDDM) patients, microalbuminuria predicts early mortality, predominantly from cardiovascular disease. Increased free radical activity and abnormalities in hemostasis have been implicated in the development of vascular disease. Therefore, we measured markers of free radical activity (nonperoxide-conjugated diene isomer of linoleic acid [PL-9,11-LA'] and lipid peroxides expressed as malondialdehyde [MDA]) along with the hemostatic variables: fibrinogen, von Willebrand factor (vWf), plasminogen activator inhibitor (PAI-1), tissue plasminogen activator (t-PA), and plasmin activity (B beta 15-42) in 24 NIDDM patients (12 patients with microalbuminuria and 12 without microalbuminuria) and in 12 age-matched control subjects. There were no differences in linoleic acid (PL-9,12-LA) concentrations between the three groups. PL-9,11-LA' was elevated in the microalbuminuric patients compared with control subjects (P less than 0.05), but there was no difference between the two diabetic groups. MDA was elevated in the microalbuminuric diabetic patients compared with those patients without microalbuminuria (P less than 0.05) and control subjects (P less than 0.001). MDA was also increased in the patients without microalbuminuria compared with control subjects (P less than 0.01). Except for B beta 15-42, all the hemostatic variables were increased (P less than 0.05) in the diabetic patients compared with control subjects. The microalbuminuric diabetic patients had further increases in vWf (P less than 0.03) and t-PA (P less than 0.03) compared with patients with microalbuminuria. Our study suggests that there is an increase in free radical activity and abnormalities in hemostatic variables favoring a hypercoagulable state in NIDDM, especially in those with microalbuminuria.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Pre-hospital transfusion of plasma in hemorrhaging trauma patients independently improves hemostatic competence and acidosis.

    PubMed

    Henriksen, Hanne H; Rahbar, Elaheh; Baer, Lisa A; Holcomb, John B; Cotton, Bryan A; Steinmetz, Jacob; Ostrowski, Sisse R; Stensballe, Jakob; Johansson, Pär I; Wade, Charles E

    2016-12-09

    The early use of blood products has been associated with improved patient outcomes following severe hemorrhage or traumatic injury. We aimed to investigate the influence of pre-hospital blood products (i.e. plasma and/or RBCs) on admission hemostatic properties and patient outcomes. We hypothesized that pre-hospital plasma would improve hemostatic function as evaluated by rapid thrombelastography (rTEG). We conducted a prospective observational study recruiting 257 trauma patients admitted to a Level I trauma center having received either blood products pre-hospital or in-hospital within 6 hours of admission. Clinical data on patient demographics, blood biochemistry, injury severity score and mortality were collected. Admission rTEG was conducted to characterize the coagulation profile and hemostatic function. 75 patients received pre-hospital plasma and/or RBCs (PH group; nearly half received both RBCs and plasma) whereas 182 patients only received in-hospital blood products (RBCs, Plasma and Platelets) within 6 hours of admission (IH group). PH patients had lower Glasgow coma scale (GCS) scores, more penetrating injuries, lower systolic blood pressures, lower hemoglobin levels, lower platelet counts and greater acidosis upon ED admission than the IH group (all p < 0.05). Despite differences in type of injury and admission vitals indicating that the PH group had more signs of bleeding than the IH group, there were no significant differences in in-hospital mortality (PH 26.7% vs. IH 20.9% p = 0.31). When comparing rTEG variables between PH patients transfused with 0, 1 or 2 units of plasma, more pre-hospital plasma transfusion was tendency towards improved rTEG variables. When adjusting for pre-hospital RBC, pre-hospital plasma was associated with significantly higher rTEG MA (p = 0.012) at hospital admission. After adjusting for pre-hospital RBCs, pre-hospital plasma transfusion was independently associated with increased rTEG MA, as well as arrival indices of

  16. Local hemostatic matrix for endoscope-assisted removal of intracerebral hemorrhage is safe and effective.

    PubMed

    Luh, Hui-Tzung; Huang, Abel Po-Hao; Yang, Shih-Hung; Chen, Chien-Ming; Cho, Der-Yang; Chen, Chun-Chung; Kuo, Lu-Ting; Li, Chieh-Hsun; Wang, Kuo-Chuan; Tseng, Wei-Lung; Hsing, Ming-Tai; Yang, Bing-Shiang; Lai, Dar-Ming; Tsai, Jui-Chang

    2018-01-01

    Minimally invasive endoscope-assisted (MIE) evacuation of spontaneous intracerebral hemorrhage (ICH) is simple and effective, but the limited working space may hinder meticulous hemostasis and might lead to rebleeding. Management of intraoperative hemorrhage is therefore a critical issue of this study. This study presents experience in the treatment of patients with various types of ICH by MIE evacuation followed by direct local injection of FloSeal Hemostatic Matrix (Baxter Healthcare Corp, Fremont, CA, USA) for hemostasis. The retrospective nonrandomized clinical and radiology-based analysis enrolled 42 patients treated with MIE evacuation of ICH followed by direct local injection of FloSeal Hemostatic Matrix. Rebleeding, morbidity, and mortality were the primary endpoints. The percentage of hematoma evacuated was calculated from the pre- and postoperative brain computed tomography (CT) scans. Extended Glasgow Outcome Scale (GOSE) was evaluated at 6 months postoperatively. Forty-two ICH patients were included in this study, among these, 23 patients were putaminal hemorrhage, 16 were thalamic ICH, and the other three were subcortical type. Surgery-related mortality was 2.4%. The average percentage of hematoma evacuated was 80.8%, and the rebleeding rate was 4.8%. The mean operative time was 102.7 minutes and the average blood loss was 84.9 mL. The mean postoperative GOSE score was 4.55 at 6-months' follow-up. This study shows that local application of FloSeal Hemostatic Matrix is safe and effective for hemostasis during MIE evacuation of ICH. In our experience, this shortens the operation time, especially in cases with intraoperative bleeding. A large, prospective, randomized trial is needed to confirm the findings. Copyright © 2017. Published by Elsevier B.V.

  17. Endothelial effects of hemostatic devices for continuous cardioplegia or minimally invasive operations.

    PubMed

    Perrault, L P; Menasché, P; Wassef, M; Bidouard, J P; Janiak, P; Villeneuve, N; Jacquemin, C; Bloch, G; Vilaine, J P; Vanhoutte, P M

    1996-10-01

    Improvements in myocardial protection may include the continuous delivery of normothermic blood cardioplegia. Technical aids are required for optimal visualization of the operative field during the performance of coronary anastomoses if cardioplegia is to be given continuously or during minimally invasive operations. However, the effects of the different hemostatic devices on coronary endothelial function are unknown. We compared the effects on endothelial function of two commonly used hemostatic techniques, coronary clamping and gas jet insufflation, with those of a technique using extravascular balloon occlusion to mimic systolic luminal closure by the surrounding myocardium. The three techniques were applied for 15 minutes on porcine epicardial coronary arteries from explanted hearts. For coronary clamping, standard bulldog clamps were used. Gas jet insufflation was applied by blowing oxygen (12 L/min) tangentially at a 45-degree angle 1 cm away from a 3-mm arteriotomy. Extravascular balloon occlusion was achieved with a needle-tipped silicone loop, the midportion of which, once positioned beneath the coronary artery, was inflated to push a myocardial "cushion" against the back of the vessel until its occlusion. Control rings were taken from the same coronary artery. The endothelial function of control and instrumented arterial rings was then studied in organ chambers filled with modified Krebs-Ringer bicarbonate solution. Contractions to potassium chloride and prostaglandin F2 alpha and endothelium-independent relaxation to sin-1, a nitric oxide donor, were unaffected in all groups. Endothelium-dependent relaxation to serotonin was impaired after clamping and preserved after gas jet insufflation and extravascular balloon occlusion. Maximal endothelium-dependent relaxation to serotonin was as follows: for coronary clamping, 63% +/- 6% versus 87% +/- 3% in controls; for gas jet insufflation, 67% +/- 12% versus 88% +/- 7%; and for extraluminal balloon occlusion

  18. Effectiveness of the addition of Lidocaine to a hemostatic, bioresorbable putty in the treatment of iliac crest donor site pain.

    PubMed

    Müller, Marc Andreas; Mehrkens, Arne; Zürcher, Roman; Vavken, Patrick; Valderrabano, Victor

    2014-12-08

    The harvest of iliac crest bone grafts (ICBG) is associated with relevant donor site pain, but may be lowered by the application of lidocaine loaded on biodegradable, hemostatic putty for sustained local analgesic release. The goal of this double-blind controlled trial was to assess the efficacy of adding lidocaine to a hemostatic putty (Orthostat ™) to treat donor site pain following harvest of ICBG in foot and ankle procedures. After ICBG harvest during a foot and ankle procedure, the resulting bone defect was either filled with Orthostat™ (n = 7) or with the same hemostatic putty loaded with lidocaine (Orthostat-L™, n = 7). During the first 72 postoperative hours, donor site and surgical site pain were managed by patient controlled morphine delivery and a peripheral nerve block. Donor site pain was periodically quantified on a Visual Analog (VAS) and a Wong Baker FACES scale. Pain scores were plotted over time to calculate the area under the curve (AUC) to quantify the overall pain experienced in specific time intervals. Orthostat-L™ significantly reduced donor site pain over the first 12 hours postoperatively as evidenced by a significant decrease of the AUC in both VAS (p = 0.0366) and Wong Baker FACES pain score plots (p = 0.0024). Cumulated morphine uses were not significantly decreased with Orthostat-L™. The addition of lidocaine to a hemostatic putty offers a significant ICBG donor site pain reduction over the first 12 postoperative hours. ClinicalTrials.gov NCT01504035. Registered January 2nd 2012.

  19. Use of a contoured bioresorbable plate with a hemostatic plug to control life-threatening bleeding from the superior sagittal sinus during hemispherotomy: technical note.

    PubMed

    Tuite, Gerald F; Carey, Carolyn M; Nelson, William W; Raffa, Scott J; Winesett, S Parrish

    2016-10-01

    Profuse bleeding originating from an injured cerebral sinus can be a harrowing experience for any surgeon, particularly during an operation on a young child. Common surgical remedies include sinus ligation, primary repair, placement of a hemostatic plug, and patch or venous grafting that may require temporary stenting. In this paper the authors describe the use of a contoured bioresorbable plate to hold a hemostatic plug in place along a tear in the inferomedial portion of a relatively inaccessible part of the posterior segment of the superior sagittal sinus in an 11-kg infant undergoing hemispherotomy for epilepsy. This variation on previously described hemostatic techniques proved to be easy, effective, and ultimately lifesaving. Surgeons may find this technique useful in similar dire circumstances when previously described techniques are ineffective or impractical.

  20. [Bed-side management of post-operative bleeding in transurethral resection of the prostate--hemostatic trial with thrombin solution injected into the resected cavity of the prostate].

    PubMed

    Hasegawa, S; Nakashima, J; Kimura, S

    1987-08-01

    To control post-operative bleeding from the resected cavity in transurethral resection of the prostate (TUR-P), 20,000 units of thrombin dissolved in 5-20 ml of physiological saline was injected into the cavity in one shot with a new type of 3-way Foley catheter. The catheter has two holes close to the balloon, and the holes provide outlets through which the solution is directly injected into the cavity. Out of 23 patients between 58 and 87 years old, 11 were given thrombin and 12 were control cases. In each case, urine blood volume (ml/hr) was determined before (a) and after (b) injection. The hemostatic effect was assessed with a "hemostatic index" of b/a. There was a statistically significant difference in the hemostatic indices between thrombin group and the control. (p less than 0.02) This new hemostatic method proved to be a very useful easy bed-side technique to control bleeding even in sudden bleeding after TUR-P. No serious side effects were found during the course of this study.

  1. Radial hemostasis is facilitated with a potassium ferrate hemostatic patch: the Statseal with TR band assessment trial (STAT).

    PubMed

    Seto, Arnold H; Rollefson, William; Patel, Mitul P; Suh, William M; Tehrani, David M; Nguyen, Jacqueline A; Amador, Daniel G; Behnamfar, Omid; Garg, Vinisha; Cohen, Mauricio G

    2018-05-15

    Hemostasis is a limiting factor for discharge after uncomplicated transradial procedures. The potassium ferrate hemostatic patch (PFHP) may serve as an adjunct to the air-bladder TR band (TRB) and allow expedited deflation of the TRB. Prospective multicenter randomized controlled trial comparing radial hemostatic protocols. Deflation of the TRB was attempted at 40 minutes with PFHP and at 120 minutes without the PFHP. The primary outcome was time to full deflation of the TRB with hemostasis. At four U.S. sites, 180 patients were enrolled after receiving a minimum of 5,000 units of unfractionated heparin or bivalirudin. Interventions comprised 30% of procedures. Successful TRB deflation occurred at 43 ± 14 minutes with PFHP and 160 ± 43 minutes without PFHP (p<0.001). Minor hematomas occurred in 9 (10.3%) of TRB patients and 16 (17.2%) of PFHP patients (p=0.20). Radial artery occlusion occurred in 2% of patients in the PFHP group (p=NS). Outpatients randomized to PFHP were discharged 51 ± 83.5 minutes earlier than control. The PFHP hemostatic patch facilitated early deflation of the TRB with a nonsignificant increase in forearm hematomas. Use of the PFHP may improve patient throughput and allow for earlier discharge following transradial procedures.

  2. Comparison of 10 Hemostatic Dressings in a Groin Puncture Model in Swine

    DTIC Science & Technology

    2009-09-01

    attended or remote surgical theaters as well as for first aid bandaging in extreme sport.Methods to suppress massive external hemorrhage should be provided...Products Newport, O Instaclot (IC) Emergency Medical Devices Loxa WoundStat (WS) TraumaCure, Inc. Bethesda, Md Solid (flexible) agents Alpha Bandage ...referred to throughout are listed in Table I. The hemostatic products and the standard compressed gauze bandage (SD; H&H compressed gauze, H&H

  3. Hemostats, sealants, and adhesives: components of the surgical toolbox.

    PubMed

    Spotnitz, William D; Burks, Sandra

    2008-07-01

    The surgical toolbox is expanding, and newer products are being developed to improve results. Reducing blood loss so that bloodless surgery can be performed may help minimize morbidity and length of stay. As patients, hospital administrators, and government regulators desire less invasive procedures, the surgical technical challenge is increasing. More operations are being performed through minimally invasive incisions with laparoscopic, endoscopic, and robotic approaches. In this setting, tools that can reduce bleeding by causing blood to clot, sealing vessels, or gluing tissues are gaining an increasing importance. Thus, hemostats, sealants, and adhesives are becoming a more important element of surgical practice. This review is designed to facilitate the reader's basic knowledge of these tools so that informed choices are made for controlling bleeding in specific clinical situations. Such information is useful for all members of the operative team. The team includes surgeons, anesthesiologists, residents, and nurses as well as hematologists and other medical specialists who may be involved in the perioperative care of surgical patients. An understanding of these therapeutic options may also be helpful to the transfusion service. In some cases, these materials may be stored in the blood bank, and their appropriate use may reduce demand for other transfusion components. The product classification used in this review includes hemostats as represented by product categories that include mechanical agents, active agents, flowables, and fibrin sealants; sealants as represented by fibrin sealants and polyethylene glycol hydrogels; and adhesives as represented by cyanoacrylates and albumin cross-linked with glutaraldehyde. Only those agents approved by the Food and Drug Administration (FDA) and presently available (February 2008) for sale in the United States are discussed in this review.

  4. Experienced iPad-Using Early Childhood Teachers: Practices in the One-to-One iPad Classroom

    ERIC Educational Resources Information Center

    Lu, Ya-Huei; Ottenbreit-Leftwich, Anne T.; Ding, Ai-Chu; Glazewski, Krista

    2017-01-01

    Although many elementary schools have adopted one-to-one programs, we still lack information on how teachers integrate iPads or other tablets into their daily instruction, especially in early childhood settings. The purpose of this case study was to present how four experienced iPad-using early childhood teachers integrated one-to-one iPads into…

  5. In vitro comparison of two widely used surgical sealants for treating alveolar air leak.

    PubMed

    Zhang, Ruoyu; Bures, Maximilian; Höffler, Klaus; Jonigk, Danny; Haverich, Axel; Krueger, Marcus

    2014-12-01

    Controversies surrounding the efficacy of sealants against alveolar air leak (AAL) are abundant in the literature. We sought to test the widely used sealants, TachoSil (Takeda Pharmaceutical Company Limited, Osaka, Japan) and BioGlue (CryoLife Europa Ltd., Surrey, United Kingdom) in an in vitro model. Materials and After creation of a focal superficial defect (40 × 25 mm) in swine lungs (n=40), AAL was assessed with increasing inspired tidal volume (TVi). Upon sealant application in a randomized order, AAL was assessed in the same way until sealant burst. At TVi =400, 500, 600, and 700 mL, BioGlue achieved sealing in 19, 19, 16, and 14 tests, while TachoSil sealed in 19, 14, 4, and no test, respectively. The maximally tolerated pressure of BioGlue was higher than TachoSil (40.3 ± 3.0 vs. 36.0 ± 4.9 cm H2O, p=0.003). Cohesive and adhesive failures were found in 10 and 1 tests of BioGlue, respectively, while all burst failures of TachoSil were adhesive. Concerning elasticity, TachoSil allowed more expansion of the covered defect than BioGlue (6.3 ± 3.9 vs. 1.4 ± 1.0 mm, p<0.001). The tested sealants demonstrated high sealing efficacy. While BioGlue was superior in resisting higher ventilation pressure, TachoSil possessed better elasticity. Georg Thieme Verlag KG Stuttgart · New York.

  6. Stent-Grafts in the Management of Hemorrhagic Complications Related to Hemostatic Closure Devices: Report of Two Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giansante Abud, Daniel; Mounayer, Charbel; Saint-Maurice, Jean Pierre

    We report 2 cases of hemorrhagic complications related to use of the Angio-Seal hemostatic closure device that were successfully managed with stent-grafts. Two patients with subarachnoid hemorrhage were referred to our departments for endovascular treatment of ruptured intracranial aneurysms. The treatment was performed through a femoral access; the sheaths were removed immediately after the procedures, and the punctures sites closed by Angio-Seals. Both patients presented clinical signs of hypovolemic shock after treatment. The diagnosis of active bleeding through the puncture site was made by emergency digital subtraction angiography. The lesions were managed with stent-grafts. The use of stent-grafts proved tomore » be efficient in the management of these life-threatening hemorrhagic complications following the use of the Angio-Seal hemostatic closure device.« less

  7. [Modern biomaterials as hemostatic dressings in kidney nephron sparing surgery (NSS)--murine model. A preliminary report].

    PubMed

    Nowacki, Maciej; Jundziłł, Arkadiusz; Bieniek, Miłosz; Kowalczyk, Tomasz; Kloskowski, Tomasz; Drewa, Tomasz

    2012-01-01

    Kidney cancer is now days, one of the main problems in oncological urology. More frequent cases detection of this type of cancer and the implementation of modern methods of treatment, involves the public and good diagnostic radiological imaging methods. Approximately 40% of renal tumors are detected clinically as a changes in T1N0M0 stage. This means that in these patients, surgery can be performed using the method of nephron sparing surgery (NSS), far from consisting the implementation of radical nephrectomy. Unfortunately, despite the saving nature of this type of treatment, NSS methods are associated with local recurrence of tumor formation. Another problem is intra operative bleeding, that's why in order to stop this negative process surgeons currently use hemostatic dressings. Potentially and clinically significant solution could be a combination of this two main problematics points of concern, through the use of modern biomaterials coated on oncostatic substances as a haemostatic dressings, to the prevention of tumor recurrence. The aim of this work, was to present preliminary report of the use of advanced biomaterials, as haemostatic dressings in an experimental technique of nephron sparing surgery on an murine model. In the experiment we use two types of biomaterials and the standard haemostatic dressing used in the nephron sparing surgery (NSS) as a control. We use a polycaprolactone biomaterial obtained by electrospinning. As a second type of biomaterial, we use a homogeneous material with a structure similar to wool, also obtained from medical polycaprolactone by electrospinning. As an murine (in vivo) model in the study, we use 10 C57BL/J mice (with the local ethical committee permission). 8 mice were used in the present study, 2 mice were constituted as a separate control for obtaining the bleeding data. Kidney melanoma cells were implanted under the C57B1/J B16 mouse kidney fibrous capsule, one week before NSS. After 3 weeks the animals were

  8. 21 CFR 878.4440 - Eye pad.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is...

  9. 21 CFR 878.4440 - Eye pad.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is...

  10. 21 CFR 878.4440 - Eye pad.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is...

  11. Improved Helmet-Padding Material

    NASA Technical Reports Server (NTRS)

    Dawn, Frederic S.; Weiss, Fred R.; Eck, John D.

    1994-01-01

    Polyimide foamed into lightweight padding material for use in helmets. Exhibits increased resistance to ignition, combustion, and impact, and it outgasses less. Foam satisfies offgassing and toxicity requirements of NASA/JSC criteria (NHB80601B). Helmets containing this improved padding material used by firefighters, police, offshore drilling technicians, construction workers, miners, and race-car drivers.

  12. STS_135_Pad

    NASA Image and Video Library

    2011-06-02

    JSC2011-E-059493 (31 May 2011) --- The space shuttle Atlantis is seen in the background on Launch Pad 39A at NASA?s Kennedy Space Center in Florida on May 31, 2011. The crawler/transporter is seen slowly driving away from the launch pad after making its final scheduled delivery of a shuttle. The orbiter is scheduled to fly the final mission of the Space Shuttle Program, launching on July 8. Photo credit: NASA Photo/Houston Chronicle, Smiley N. Pool

  13. Cosmological applications of Padé approximant

    NASA Astrophysics Data System (ADS)

    Wei, Hao; Yan, Xiao-Peng; Zhou, Ya-Nan

    2014-01-01

    As is well known, in mathematics, any function could be approximated by the Padé approximant. The Padé approximant is the best approximation of a function by a rational function of given order. In fact, the Padé approximant often gives better approximation of the function than truncating its Taylor series, and it may still work where the Taylor series does not converge. In the present work, we consider the Padé approximant in two issues. First, we obtain the analytical approximation of the luminosity distance for the flat XCDM model, and find that the relative error is fairly small. Second, we propose several parameterizations for the equation-of-state parameter (EoS) of dark energy based on the Padé approximant. They are well motivated from the mathematical and physical points of view. We confront these EoS parameterizations with the latest observational data, and find that they can work well. In these practices, we show that the Padé approximant could be an useful tool in cosmology, and it deserves further investigation.

  14. Robotic surgery and hemostatic agents in partial nephrectomy: a high rate of success without vascular clamping.

    PubMed

    Morelli, Luca; Morelli, John; Palmeri, Matteo; D'Isidoro, Cristiano; Kauffmann, Emanuele Federico; Tartaglia, Dario; Caprili, Giovanni; Pisano, Roberta; Guadagni, Simone; Di Franco, Gregorio; Di Candio, Giulio; Mosca, Franco

    2015-09-01

    Robot-assisted partial nephrectomy has been proposed as a technique to overcome technical challenges of laparoscopic partial nephrectomy. We prospectively collected and analyzed data from 31 patients who underwent robotic partial nephrectomy with systematic use of hemostatic agents, between February 2009 and October 2014. Thirty-three renal tumors were treated in 31 patients. There were no conversions to open surgery, intraoperative complications, or blood transfusions. The mean size of the resected tumors was 27 mm (median 20 mm, range 5-40 mm). Twenty-seven of 33 lesions (82%) did not require vascular clamping and therefore were treated in the absence of ischemia. All margins were negative. The high partial nephrectomy success rate without vascular clamping suggests that robotic nephron-sparing surgery with systematic use of hemostatic agents may be a safe, effective method to completely avoid ischemia in the treatment of selected renal masses.

  15. [Change in Perioperative Hemostatic Function in Patients Undergoing Hepatic Resection for Primary and Metastatic Liver Cancer].

    PubMed

    Komasawa, Nobuyasu; Ueki, Ryusuke; Atagi, Kazuaki; Nishi, Shinichi

    2015-08-01

    Patients undergoing primary hepatic resection often develop hemostatic dysfunction associated with cirrhosis. We retrospectively surveyed pre- and postoperative prothrombin time (PT) and the PT expressed as international normalized ratio (PT-INR) in 39 patients undergoing primary liver resection. We also compared PT changes between primary and metastatic cancer cases (8 cases). Postoperative PT-INR was 1.40 ± 0.38, which was significantly prolonged compared to preoperative PT-INR of 1.08 ± 0.07. Preoperative PT was over 70% in all 39 patients undergoing primary liver resection, whereas postoperative PT was less than 60% in 13 of 39 patients. No significant difference was found in preoperative PT-INR between primary and metastatic cancer cases, but postoperative PT-INR was significantly prolonged in primary cancer cases. Patients undergoing primary liver resection are susceptible to hemostatic dysfunction, even with preoperative PT levels within normal limits.

  16. Electrostatic Evaluation of the SRB Velostat(Trademark) Pads

    NASA Technical Reports Server (NTRS)

    Buhler, Charles R.; Calle, Carlos I.

    2007-01-01

    During RSRM Grain inspection, pads constructed of Velostat are grounded and installed in the RSRM bore enabling inspectors to move throughout the bore during the inspection. Velostat pads are installed by grounding the first pad installed and subsequent pads are installed overlapping the previously installed pad maintaining a conductive path to facility ground. Pads are removed upon completion of the inspection in a reverse fashion. As the pads are removed scanning of propellant surfaces is performed per OMRS. During PPICI Audit of B5308.006 (Forward Segment Grain Inspection) in October 07 one audit finding noted that electrostatic scanning of propellant surfaces was being performed during removal of conductive pads following grain inspection. ATK does not perform electrostatic scanning of propellant surfaces during pad removal following final inspection at the plant. The integrated team consisting of NASA SE, USA SE, USA QE, ATK LSS, ATK Systems Safety and ATK DE concurred that electrostatic scanning of propellant surfaces was unnecessary as the conductive pads are grounded. Additional time spent in bore performing scanning presents itself as additional risk. Technicians reported that they have never seen any voltage readings while scanning propellant surfaces during pad removal. USA Systems engineering has written KB 17530 in response to the finding which will delete the requirement (item 2 B47GEN.ll0) to scan propellant surfaces during pad removal. As a result of an E3 panel discussion on December 13, 2007, it was decided that verification of the electrical grounding of the Velostat pads be verified.

  17. 21 CFR 878.4440 - Eye pad.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs... GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is... use as a bandage over the eye for protection or absorption of secretions. (b) Classification. Class I...

  18. 21 CFR 878.4440 - Eye pad.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Eye pad. 878.4440 Section 878.4440 Food and Drugs... GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4440 Eye pad. (a) Identification. An eye pad is... use as a bandage over the eye for protection or absorption of secretions. (b) Classification. Class I...

  19. Cost-consequence analysis of different active flowable hemostatic matrices in cardiac surgical procedures.

    PubMed

    Makhija, D; Rock, M; Xiong, Y; Epstein, J D; Arnold, M R; Lattouf, O M; Calcaterra, D

    2017-06-01

    A recent retrospective comparative effectiveness study found that use of the FLOSEAL Hemostatic Matrix in cardiac surgery was associated with significantly lower risks of complications, blood transfusions, surgical revisions, and shorter length of surgery than use of SURGIFLO Hemostatic Matrix. These outcome improvements in cardiac surgery procedures may translate to economic savings for hospitals and payers. The objective of this study was to estimate the cost-consequence of two flowable hemostatic matrices (FLOSEAL or SURGIFLO) in cardiac surgeries for US hospitals. A cost-consequence model was constructed using clinical outcomes from a previously published retrospective comparative effectiveness study of FLOSEAL vs SURGIFLO in adult cardiac surgeries. The model accounted for the reported differences between these products in length of surgery, rates of major and minor complications, surgical revisions, and blood product transfusions. Costs were derived from Healthcare Cost and Utilization Project's National Inpatient Sample (NIS) 2012 database and converted to 2015 US dollars. Savings were modeled for a hospital performing 245 cardiac surgeries annually, as identified as the average for hospitals in the NIS dataset. One-way sensitivity analysis and probabilistic sensitivity analysis were performed to test model robustness. The results suggest that if FLOSEAL is utilized in a hospital that performs 245 mixed cardiac surgery procedures annually, 11 major complications, 31 minor complications, nine surgical revisions, 79 blood product transfusions, and 260.3 h of cumulative operating time could be avoided. These improved outcomes correspond to a net annualized saving of $1,532,896. Cost savings remained consistent between $1.3m and $1.8m and between $911k and $2.4m, even after accounting for the uncertainty around clinical and cost inputs, in a one-way and probabilistic sensitivity analysis, respectively. Outcome differences associated with FLOSEAL vs SURGIFLO

  20. Functionally Different Pads on the Same Foot Allow Control of Attachment: Stick Insects Have Load-Sensitive “Heel” Pads for Friction and Shear-Sensitive “Toe” Pads for Adhesion

    PubMed Central

    Labonte, David; Federle, Walter

    2013-01-01

    Stick insects (Carausius morosus) have two distinct types of attachment pad per leg, tarsal “heel” pads (euplantulae) and a pre-tarsal “toe” pad (arolium). Here we show that these two pad types are specialised for fundamentally different functions. When standing upright, stick insects rested on their proximal euplantulae, while arolia were the only pads in surface contact when hanging upside down. Single-pad force measurements showed that the adhesion of euplantulae was extremely small, but friction forces strongly increased with normal load and coefficients of friction were 1. The pre-tarsal arolium, in contrast, generated adhesion that strongly increased with pulling forces, allowing adhesion to be activated and deactivated by shear forces, which can be produced actively, or passively as a result of the insects' sprawled posture. The shear-sensitivity of the arolium was present even when corrected for contact area, and was independent of normal preloads covering nearly an order of magnitude. Attachment of both heel and toe pads is thus activated partly by the forces that arise passively in the situations in which they are used by the insects, ensuring safe attachment. Our results suggest that stick insect euplantulae are specialised “friction pads” that produce traction when pressed against the substrate, while arolia are “true” adhesive pads that stick to the substrate when activated by pulling forces. PMID:24349156

  1. Product comparison model in otolaryngology: Equivalency analysis of absorbable hemostatic agents after endoscopic sinus surgery.

    PubMed

    Antisdel, Jastin L; Meyer, Annika; Comer, Brett; Jang, David; Gurrola, Jose; Khabbaz, Eyad; Christopher, Kara; Kountakis, Stilianos

    2016-01-01

    Evidence-based medicine in otolaryngology literature continues to be lacking, especially with regard to new products brought to market. The marketing of products often includes statements of benefit that have limited objective support in research or literature. To address this, and to adequately determine product equivalency/superiority, careful evaluation must be made. In order to establish standards for this process in rhinology products, we directly compare three different absorbable hemostatic agents in patients with chronic rhinosinusitis (CRS) after undergoing endoscopic sinus surgery (ESS), using both objective and subjective outcomes. Double-blinded prospective (level 1) comparison and equivalency analysis of three plant-based absorbable hemostatic agents (carboxymethylcellulose [CMC] gel, mucopolysaccharide hemospheres (MPH), and potato starch wafer) in patients undergoing bilateral ESS. Patients with medically refractory CRS who underwent bilateral ESS were recruited and prospectively followed. At the conclusion of ESS, one of three different hemostatic agents was applied to each nasal passage. Subjective patient data was obtained using rated symptoms compared between the two sides (nasal obstruction, bleeding, pain, and nasal discharge) at baseline and on postoperative days 1, 7, and 14. Objective data was obtained by blinded endoscopic scoring to rate mucosal edema, inflammation, granulation, crusting, infection, and synechiae formation on postoperative weeks 1, 3, and 6. Forty-eight patients who underwent ESS for CRS were included. There is no statistical difference in subjective scores for any of the variables measured, although (MPH) nearly reached statistical significance at postoperative day 7 for increased pain (P = 0.06) and obstruction (P = 0.22). Objective measures showed equivalency between all products, except the CMC gel approached significance at week 3 for increased crusting (P = 0.10), granulation (P = 0.24), and debridement (P = 0

  2. Randomized clinical trial comparing cold knife conization of the cervix with and without lateral hemostatic sutures.

    PubMed

    Bueno, Letícia Rossi; Binda, Marcia; Monego, Heleusa; Scherer, Roberta Luísa; Rolim, Karen Machado; Bottini, Alessandra Leal; Fregnani, José H T G; dos Reis, Ricardo

    2015-06-01

    Compare blood loss during cold knife conization of the cervix with and without lateral hemostatic sutures in the cervical branches of the uterine arteries. Randomized clinical trial. Hospital de Clínicas de Porto Alegre (HCPA). 102 patients that underwent cold knife conization. Women that underwent cold knife conization of the cervix were randomized to undergo the procedure with or without lateral hemostatic sutures. blood loss measured in grams. operative time and postoperative intervention. Only the participants were blinded to group assignment. From March 2009 to August 2012, patients were randomly assigned to one of the study groups. There were no differences in amount of blood loss between patients that underwent the procedure with and without sutures (p = 0.39). Operative time was shorter in the group without suture (p = 0.020). There were no differences in intervention due to bleeding (p = 0.20). Blood loss was greater among menstruating women than for menopausal women (p = 0.011). There were no differences in amount of blood lost between smoking and nonsmoking patients (p = 0.082). Lateral hemostatic sutures do not affect the amount of intraoperative bleeding or the number of postoperative interventions. Their use is not necessary because they result in longer operative time, have a higher cost due to the use of suture material and pose the risk of ureter lesion in case the sutures are not placed at a lower position in the cervix. ClinicalTrials. gov identifier: NCT02184975. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  3. Role of the Hemostatic System on SCD Pathophysiology and Potential Therapeutics

    PubMed Central

    Pakbaz, Zahra; Wun, Ted

    2014-01-01

    Synopsis Recent studies suggest that sickle cell disease is a hypercoagulable state contributing to the vaso-occlusive events in microcirculation resulting in acute and chronic sickle cell related organ damage. In this article, we will review the existing evidence for contribution of hemostatic system perturbation to sickle cell disease pathophysiology. We will also review the data showing increased risk of thromboembolic events, particularly newer information on the incidence of VTE. Finally, the potential role of platelet inhibitors and anticoagulants in SCD will be briefly reviewed. PMID:24589271

  4. Associations of Serum 25-Hydroxyvitamin D With Hemostatic and Inflammatory Biomarkers in the Multi-Ethnic Study of Atherosclerosis

    PubMed Central

    Cushman, Mary; Jenny, Nancy; Michos, Erin D.; Smith, Nicholas L.; Kestenbaum, Bryan; de Boer, Ian H.

    2016-01-01

    Context: Mechanisms explaining documented associations of 25-hydroxyvitamin D [25(OH)D] deficiency with increased risks of cardiovascular disease (CVD) and venous thromboembolism may relate to adverse hemostatic and inflammatory responses. Objective: To evaluate whether 25(OH)D deficiency is associated with a prothrombotic and proinflammatory biological profile. Design: Cross-sectional analyses. Setting: The Multi-Ethnic Study of Atherosclerosis, a multicenter prospective cohort of American adults. Participants: Up to 6554 adults free of CVD. Main Outcome Measures: Ten hemostatic biomarkers (D-dimer, fibrinogen, factor VIII, plasmin-antiplasmin, and homocysteine [n = 6443]; von Willebrand factor, soluble tissue factor, plasminogen activator inhibitor-1 (PAI-1), total tissue factor pathway inhibitor (TFPI), and soluble thrombomodulin [n = 814]), and three inflammatory biomarkers (IL-6, C-reactive protein [n = 6443], and TNF-α soluble receptor [n = 3802]). Results: Among 6443 subjects (46.6% men; mean age, 62.1 years; mean body mass index, 28.3 kg/m2) of White (37.8%), Black (27.2%), Chinese (12.2%), and Hispanic (21.8%) race/ethnicity, mean 25(OH)D was 25.3 ng/mL. After multiple adjustment, 25(OH)D concentrations were associated with concentrations of IL-6 and homocysteine and also with concentrations of PAI-1 and TFPI: per 10 ng/mL decrement in 25(OH)D, 5.1% higher IL-6 (95% confidence interval [CI], 3.4–6.9; P < .001); 3.7% higher homocysteine (95% CI, 3.0–4.3; P < .001); 7.0% higher PAI-1 (95% CI, 0.9–13.6; P = .025); and 2.1% higher TFPI (95% CI, 0.0–4.2; P = .047), without racial/ethnic heterogeneity. No significant associations were observed for other hemostatic and inflammatory biomarkers. Conclusions: Increased inflammation as reflected by higher circulating IL-6 and increased homocysteine concentrations may represent mechanisms linking 25(OH)D deficiency to greater risks of CVD and perhaps venous thromboembolism. Low concentrations of 25(OH)D were

  5. Flour pads: devices to improve CHESS fat suppression.

    PubMed

    Moriya, Susumu; Miki, Yukio; Miyati, Tosiaki; Kanagaki, Mitsunori; Yokobayashi, Tsuneo

    2014-01-01

    We compared the suppression of lingering fat signals in chemical shift selective (CHESS) images by pads filled with flour and pads filled with rice in a phantom and human subjects. First, we prepared a phantom by creating an empty space in a mass of lard and filling the space with air, rice, or flour. Then, we obtained MR images of the phantoms in the center of the magnetic field and at a position 8 cm to the left (off-center) to compare lingering fat signals. MR images of the knee were obtained in 10 healthy volunteers using CHESS after placing a polyurethane sponge pillow, rice pad, or flour pad in the popliteal space under the flexed knee. We visually assessed the number of areas with lingering fat signals and the statistical differences among the groups were assessed using Tukey's test. Similarly to rice, flour clearly decreased lingering fat signals in the phantom study. A similar effect was obtained in the off-center images. In the volunteer study, the mean number of areas with lingering fat signals was 2.5 with a sponge pillow, 0.5 with the rice pad, and 0.3 with the flour pad. Those numbers were significantly different using flour pad and rice pad compared with sponge pillow (P < 0.001). No significant differences were seen between flour pads and rice pads (P = 0.662). Flour pads can suppress lingering fat signals in CHESS images.

  6. Hot melt adhesive attachment pad

    NASA Technical Reports Server (NTRS)

    Fox, R. L.; Frizzill, A. W.; Little, B. D.; Progar, D. J.; Coultrip, R. H.; Couch, R. H.; Gleason, J. R.; Stein, B. A.; Buckley, J. D.; St.clair, T. L. (Inventor)

    1984-01-01

    A hot melt adhesive attachment pad for releasably securing distinct elements together is described which is particularly useful in the construction industry or a spatial vacuum environment. The attachment pad consists primarily of a cloth selectively impregnated with a charge of hot melt adhesive, a thermo-foil heater, and a thermo-cooler. These components are securely mounted in a mounting assembly. In operation, the operator activates the heating cycle transforming the hot melt adhesive to a substantially liquid state, positions the pad against the attachment surface, and activates the cooling cycle solidifying the adhesive and forming a strong, releasable bond.

  7. Lily Pad Spectra

    NASA Technical Reports Server (NTRS)

    2004-01-01

    The color image on the lower left from the panoramic camera on the Mars Exploration Rover Opportunity shows the 'Lily Pad' bounce-mark area at Meridiani Planum, Mars. This image was acquired on the 3rd sol, or martian day, of Opportunity's mission (Jan.26, 2004). The upper left image is a monochrome (single filter) image from the rover's panoramic camera, showing regions from which spectra were extracted from the 'Lily Pad' area. As noted by the line graph on the right, the green spectra is from the undisturbed surface and the red spectra is from the airbag bounce mark.

  8. A shape memory foam composite with enhanced fluid uptake and bactericidal properties as a hemostatic agent.

    PubMed

    Landsman, T L; Touchet, T; Hasan, S M; Smith, C; Russell, B; Rivera, J; Maitland, D J; Cosgriff-Hernandez, E

    2017-01-01

    Uncontrolled hemorrhage accounts for more than 30% of trauma deaths worldwide. Current hemostatic devices focus primarily on time to hemostasis, but prevention of bacterial infection is also critical for improving survival rates. In this study, we sought to improve on current devices used for hemorrhage control by combining the large volume-filling capabilities and rapid clotting of shape memory polymer (SMP) foams with the swelling capacity of hydrogels. In addition, a hydrogel composition was selected that readily complexes with elemental iodine to impart bactericidal properties to the device. The focus of this work was to verify that the advantages of each respective material (SMP foam and hydrogel) are retained when combined in a composite device. The iodine-doped hydrogel demonstrated an 80% reduction in bacteria viability when cultured with a high bioburden of Staphylococcus aureus. Hydrogel coating of the SMP foam increased fluid uptake by 19× over the uncoated SMP foam. The composite device retained the shape memory behavior of the foam with more than 15× volume expansion after being submerged in 37°C water for 15 min. Finally, the expansion force of the composite was tested to assess potential tissue damage within the wound during device expansion. Expansion forces did not exceed 0.6N, making tissue damage during device expansion unlikely, even when the expanded device diameter is substantially larger than the target wound site. Overall, the enhanced fluid uptake and bactericidal properties of the shape memory foam composite indicate its strong potential as a hemostatic agent to treat non-compressible wounds. No hemostatic device currently used in civilian and combat trauma situations satisfies all the desired criteria for an optimal hemostatic wound dressing. The research presented here sought to improve on current devices by combining the large volume-filling capabilities and rapid clotting of shape memory polymer (SMP) foams with the swelling

  9. Development of a Standard Swine Hemorrhage Model for Efficacy Assessment of Topical Hemostatic Agents

    DTIC Science & Technology

    2011-07-01

    Blw:kbourne. MD Background: The diverse infomlation of efficacy of hemostatic pmducts. obtained from different military laboratories using ...model was tested with all or some of these modifications in four experimental conditions (n = 5-6 pigs pc:r condition) using Combat Gauze (CG) as...be suitable lf.>r testing every agent and some modifications may be necessary for specific applications. fu•·thermore, laboratory studies using this

  10. Pharmacologic Hemostatic Agents in Total Joint Arthroplasty-A Cost-Effectiveness Analysis.

    PubMed

    Ramkumar, Dipak B; Ramkumar, Niveditta; Tapp, Stephanie J; Moschetti, Wayne E

    2018-03-03

    Total knee and hip arthroplasties can be associated with substantial blood loss, affecting morbidity and even mortality. Two pharmacological antifibrinolytics, ε-aminocaproic acid (EACA) and tranexamic acid (TXA) have been used to minimize perioperative blood loss, but both have associated morbidity. Given the added cost of these medications and the risks associated with then, a cost-effectiveness analysis was undertaken to ascertain the best strategy. A cost-effectiveness model was constructed using the payoffs of cost (in United States dollars) and effectiveness (quality-adjusted life expectancy, in days). The medical literature was used to ascertain various complications, their probabilities, utility values, and direct medical costs associated with various health states. A time horizon of 10 years and a willingness to pay threshold of $100,000 was used. The total cost and effectiveness (quality-adjusted life expectancy, in days) was $459.77, $951.22, and $1174.87 and 3411.19, 3248.02, and 3342.69 for TXA, no pharmacologic hemostatic agent, and EACA, respectively. Because TXA is less expensive and more effective than the competing alternatives, it was the favored strategy. One-way sensitivity analyses for probability of transfusion and myocardial infarction for all 3 strategies revealed that TXA remains the dominant strategy across all clinically plausible values. TXA, when compared with no pharmacologic hemostatic agent and with EACA, is the most cost-effective strategy to minimize intraoperative blood loss in hip and knee total joint arthroplasties. These findings are robust to sensitivity analyses using clinically plausible probabilities. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. 21 CFR 880.5270 - Neonatal eye pad.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Neonatal eye pad. 880.5270 Section 880.5270 Food... § 880.5270 Neonatal eye pad. (a) Identification. A neonatal eye pad is an opaque device used to cover and protect the eye of an infant during therapeutic procedures, such as phototherapy. (b...

  12. 21 CFR 880.5270 - Neonatal eye pad.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neonatal eye pad. 880.5270 Section 880.5270 Food... § 880.5270 Neonatal eye pad. (a) Identification. A neonatal eye pad is an opaque device used to cover and protect the eye of an infant during therapeutic procedures, such as phototherapy. (b...

  13. Which hemostatic markers add to the predictive value of conventional risk factors for coronary heart disease and ischemic stroke? The Caerphilly Study.

    PubMed

    Smith, Ann; Patterson, Chris; Yarnell, John; Rumley, Ann; Ben-Shlomo, Yoav; Lowe, Gordon

    2005-11-15

    Few studies have examined whether hemostatic markers contribute to risk of coronary disease and ischemic stroke independently of conventional risk factors. This study examines 11 hemostatic markers that reflect different aspects of the coagulation process to determine which have prognostic value after accounting for conventional risk factors. A total of 2398 men aged 49 to 65 years were examined in 1984 to 1988, and the majority gave a fasting blood sample for assay of lipids and hemostatic markers. Men were followed up for a median of 13 years, and cardiovascular disease (CVD) events were recorded. There were 486 CVD events in total, 353 with prospective coronary disease and 133 with prospective ischemic stroke. On univariable analysis, fibrinogen, low activated protein C ratio, D-dimer, tissue plasminogen activator (tPA), and plasminogen activator inhibitor-1 (PAI-1) were associated significantly with risk of CVD. On multivariable analyses with conventional risk factors forced into the proportional hazards model, fibrinogen, D-dimer, and PAI-1 were significantly associated with risk of CVD, whereas factor VIIc showed an inverse association (P=0.001). In a model that contained the conventional risk factors, the hazard ratio for subsequent CVD in the top third of the distribution of predicted risk relative to the bottom third was 2.7 for subjects without preexisting CVD. This ratio increased to 3.7 for the model that also contained the 4 hemostatic factors. Fibrinogen, D-dimer, PAI-1 activity, and factor VIIc each has potential to increase the prediction of coronary disease/ischemic stroke in middle-aged men, in addition to conventional risk factors.

  14. Disinfecting the iPad: evaluating effective methods.

    PubMed

    Howell, V; Thoppil, A; Mariyaselvam, M; Jones, R; Young, H; Sharma, S; Blunt, M; Young, P

    2014-06-01

    Tablet computers are increasingly used in healthcare, but they may carry nosocomial pathogens. There are few data available on how to clean an iPad effectively for use in the clinical setting. We aimed to identify the most effective method of decontaminating the Apple iPad, without causing damage, and establish the duration of any residual effect. Following contamination with a microbial broth (meticillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococcus (VRE) and Clostridium difficile), we examined efficacy of iPad disinfection in the laboratory using six different disinfectant wipes: Sani-Cloth CHG 2% (chlorhexidine 2%/alcohol 70%), Clorox, Tristel, Trigene, soap and water, and plain cloth. Following cleaning, iPads were recontaminated to examine residual activity. After 480 Sani-Cloth CHG 2% disinfecting episodes, functional and visual analysis of iPads was performed by blinded subjects. With the exception of Clostridium difficile, Sani-Cloth CHG 2% and Clorox wipes were most effective against MRSA and VRE, and they were significantly better than the Apple-recommended plain cloth (P ≤ 0.001). A substantial residual antimicrobial effect was seen for >6h after wiping the iPad with Sani-Cloth CHG 2% despite repeated recontamination and without further disinfection. The functionality or visual appearance of the iPad was not damaged by repeated use of Sani-Cloth CHG 2% wipes. Sani-Cloth CHG 2% wipes effectively disinfect the iPad against MRSA and VRE, with a residual antibacterial effect and without causing damage. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Pad B Liquid Hydrogen Storage Tank

    NASA Technical Reports Server (NTRS)

    Hall, Felicia

    2007-01-01

    Kennedy Space Center is home to two liquid hydrogen storage tanks, one at each launch pad of Launch Complex 39. The liquid hydrogen storage tank at Launch Pad B has a significantly higher boil off rate that the liquid hydrogen storage tank at Launch Pad A. This research looks at various calculations concerning the at Launch Pad B in an attempt to develop a solution to the excess boil off rate. We will look at Perlite levels inside the tank, Boil off rates, conductive heat transfer, and radiant heat transfer through the tank. As a conclusion to the research, we will model the effects of placing an external insulation to the tank in order to reduce the boil off rate and increase the economic efficiency of the liquid hydrogen storage tanks.

  16. Video game induced knuckle pad.

    PubMed

    Rushing, Mary E; Sheehan, Daniel J; Davis, Loretta S

    2006-01-01

    Controversy and concern surround the video game playing fascination of children. Scientific reports have explored the negative effects of video games on youth, with a growing number recognizing the actual physical implications of this activity. We offer another reason to discourage children's focus on video games: knuckle pads. A 13-year-old black boy presented with an asymptomatic, slightly hyperpigmented plaque over his right second distal interphalangeal joint. A punch biopsy specimen confirmed knuckle pad as the diagnosis, and a traumatic etiology from video game playing was suspected. Knuckle pads can be painful, cosmetically unappealing, and refractory to treatment. They can now be recognized as yet another potential adverse consequence of chronic video game playing.

  17. Taking the iPad's Measure

    ERIC Educational Resources Information Center

    Raths, David

    2012-01-01

    Soon after the iPad's release in 2010, several universities decided to issue the devices to all incoming freshmen. At the time, critics scoffed at the moves as little more than marketing gimmicks designed to attract students. In truth, few of the schools required instructors to design curriculum around the iPad or had specific plans to measure…

  18. Neutrophil interaction with the hemostatic system contributes to liver injury in rats cotreated with lipopolysaccharide and ranitidine.

    PubMed

    Deng, Xiaomin; Luyendyk, James P; Zou, Wei; Lu, Jingtao; Malle, Ernst; Ganey, Patricia E; Roth, Robert A

    2007-08-01

    Cotreatment of rats with nontoxic doses of ranitidine (RAN) and lipopolysaccharide (LPS) causes liver injury, and this drug-inflammation interaction might be a model for idiosyncratic adverse drug responses in humans. Both polymorphonuclear neutrophils (PMNs) and the hemostatic system have been shown to be important in the injury. We tested the hypothesis that PMNs cause liver injury by interacting with the hemostatic system and producing subsequent hypoxia. In rats cotreated with LPS/RAN, PMN depletion by anti-PMN serum reduced fibrin deposition and hypoxia in the liver. PMN depletion also reduced the plasma concentration of active plasminogen activator inhibitor-1 (PAI-1), a major down-regulator of the fibrinolytic system. This suggests that PMNs promote fibrin deposition by increasing PAI-1 concentration. PMNs were activated in the livers of LPS/RAN-cotreated rats as evidenced by increased staining for hypochlorous acid-modified proteins generated by the myeloperoxidase-hydrogen peroxide-chloride system of activated phagocytes. Antiserum against the PMN adhesion molecule CD18 protected against LPS/RAN-induced liver injury. Because CD18 is important for PMN transmigration and activation, these results suggest that PMN activation is required for the liver injury. Furthermore, anti-CD18 serum reduced biomarkers of hemostasis and hypoxia, suggesting the necessity for PMN activation in the interaction between PMNs and the hemostatic system/hypoxia. Liver injury, liver fibrin, and plasma PAI-1 concentration were also reduced by eglin C, an inhibitor of proteases released by activated PMNs. In summary, PMNs are activated in LPS/RAN-cotreated rats and participate in the liver injury in part by contributing to hemostasis and hypoxia.

  19. Effects of Lily Pads on Evaporation

    NASA Astrophysics Data System (ADS)

    Cooley, Keith R.; Idso, Sherwood B.

    1980-06-01

    Measurements of evaporation from open water and water partially covered by lily pads have indicated that for the portion of the surface area covered by lily pads, evaporation is reduced to about 84% of that occurring from open water.

  20. Refined methods to evaluate the in vivo hemostatic function and viability of transfused human platelets in rabbit models.

    PubMed

    Watanabe, Naohide; Nogawa, Masayuki; Ishiguro, Mariko; Maruyama, Hitomi; Shiba, Masayuki; Satake, Masahiro; Eto, Koji; Handa, Makoto

    2017-08-01

    To bridge the gap between in vitro function and clinical efficacy of platelet (PLT) transfusion products, reliable in vivo PLT functional assays for hemostasis and survival in animal models are required. However, there are no standardized methods for assessing the in vivo quality of transfused human PLTs. Plasma-depleted human PLT concentrates (PCs; Day 3, Day 5, Day 7, Day 10, and damaged) were transfused into busulfan-induced rabbits with thrombocytopenia with prolonged bleeding times 1 day after treatment with ethyl palmitate (EP) to block their reticuloendothelial systems. The hemostatic effect of PC transfusion was evaluated by the ear fine vein bleeding time. For the in vivo survival assay, splenectomized EP-treated rabbits were transfused with human PCs, and viability of the human PLTs in the rabbits was determined by flow cytometry using human PLT-specific antibodies and Trucount tubes. The hemostatic effect of PCs was slightly reduced with increasing storage periods for early time points, but more dramatically reduced for later time points. PLT survival was similar after 3 and 7 days of storage, but PLTs stored for 10 days showed significantly poorer survival than those stored only 3 days. Our new and improved protocol for in vivo assessment of transfused PLTs is sufficiently sensitive to detect subtle changes in hemostatic function and viability of human PLTs transfused into rabbit models. This protocol could contribute to preclinical in vivo functional assessment and clinical quality assurance of emerging novel PLT products such as cultured cell-derived human PLTs. © 2017 AABB.

  1. 16 CFR 1632.5 - Mattress pad test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 1632.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS... substrate. (b) Flame resistant mattress pads. The following additional requirements shall be applicable to mattress pads which contain a chemical fire retardant. (1) These mattress pads shall be tested in...

  2. Day care PNL using 'Santosh-PGI hemostatic seal' versus standard PNL: A randomized controlled study.

    PubMed

    Kumar, Santosh; Singh, Shivanshu; Singh, Prashant; Singh, Shrawan Kumar

    2016-01-01

    To compare the outcomes of tubeless day care PNL using hemostatic seal in the access tract versus standard PNL. It was a prospective randomized controlled study. Cases were randomized to either the day care group with hemostatic seal (DCS) or the control group where patients were admitted and a nephrostomy tube was placed at the conclusion of surgery. A total of 180 cases were screened and out of these, 113 were included in the final analysis. The stone clearance rates were comparable in both the groups. The mean drop in hemoglobin was significantly lower in DCS group than the control group (1.05 ±0.68 vs. 1.30 ±0.58 gm/dl, p = 0.038).Mean postoperative pain score, analgesic requirement (paracetamol) and duration of hospital stay were also significantly lower in the DCS group (3.79 ±1.23 vs. 6.12 ±0.96, 1.48 ±0.50 vs. 4.09 ±1.11 grams and 0.48 ±0.26 vs. 4.74 ±1.53 days respectively; p <0.05). The incidence of urine leakage through the access tract site was significantly lower in the DCS subgroup when compared to the controls (3.6% vs. 21.1%, p <0.05). Cases in the DCS group resumed their normal activities in a significantly shorter time (8.05 ±3.05 vs.18.42 ±4.42 days; p <0.05). Higher proportion of cases in the DCS group got re-admitted, although it was not a statistically significant number (7.1% vs. 1.8%; p = 0.21). Tubeless day care PNL with composite hemostatic tract seal is considered safe. It resulted in a significant reduction of blood loss and analgesic requirement with significantly reduced hospital stay, nephrostomy tube site morbidity and time required to resume normal activity when compared to the standard PNL. However, patients must be compliant with the given instructions and should have access to a health care facility, as few of them may need re-admission.

  3. Stopping the wave of PAD.

    PubMed

    Brazziel, Tracy; Cox, Lindsie; Drury, Christa; Guerra, Maria

    2011-11-01

    Peripheral arterial disease (PAD) has a substantial impact on individual quality of life and is a significant financial burden to society. It is underdiagnosed, and therefore, undertreated. Early detection and treatment is essential to prevent increases in morbidity and mortality. The purpose of this article is to review evidence-based articles regarding prevalence, screening, diagnosis, and management of PAD. Copyright © 2011 Lippincott Williams & Wilkins.

  4. Interactive 3D display simulator for autostereoscopic smart pad

    NASA Astrophysics Data System (ADS)

    Choe, Yeong-Seon; Lee, Ho-Dong; Park, Min-Chul; Son, Jung-Young; Park, Gwi-Tae

    2012-06-01

    There is growing interest of displaying 3D images on a smart pad for entertainments and information services. Designing and realizing various types of 3D displays on the smart pad is not easy for costs and given time. Software simulation can be an alternative method to save and shorten the development. In this paper, we propose a 3D display simulator for autostereoscopic smart pad. It simulates light intensity of each view and crosstalk for smart pad display panels. Designers of 3D display for smart pad can interactively simulate many kinds of autostereoscopic displays interactively by changing parameters required for panel design. Crosstalk to reduce leakage of one eye's image into the image of the other eye, and light intensity for computing visual comfort zone are important factors in designing autostereoscopic display for smart pad. Interaction enables intuitive designs. This paper describes an interactive 3D display simulator for autostereoscopic smart pad.

  5. The role of hemostatic agents in preventing complications in laparoscopic partial nephrectomy

    PubMed Central

    y Gregorio, Sergio Alonso; Rivas, Juan Gómez; Bazán, Alfredo Aguilera; Sebastián, Jesús Díez; Martínez-Piñeiro, Luis

    2017-01-01

    Introduction Nephron-sparing surgery is currently the treatment of choice for renal cell carcinoma stage T1a. During the past years, several hemostatic agents (HA) have been developed in order to reduce surgical complications. We present the results of our series and the impact of the use of HA in the prevention of surgical complications in laparoscopic partial nephrectomies (LPNs). Material and methods We retrospectively analyzed all LPN performed in our center from 2005 to 2012. A total of 77 patients were included for analysis. Patients were divided into two groups: Group A (no use of HA) and Group B (use of HA). HA used included gelatin matrix thrombin (FloSeal) and oxidized regenerated cellulose (Surgicel). Demographics, perioperative variables, and complications were analyzed with a special interest in postoperative bleeding and urinary leakage. Results Median age was 57.17 years old (±12.1), 72.7% were male, most common comorbidities were hypertension (33.8%) and diabetes mellitus (18.2%). All patients had one solitary tumor, and 87% had a tumor ≤4 cm. Renal cell carcinoma was found in 79.2% of cases, and 78.7% were stage pT1a. and were used in 36 cases (46.8%). No differences were found in demographics, perioperative variables, and complications between groups. No conversions to open surgery or perioperative mortality were reported. Conclusions We conclude that in our series the use of a hemostatic agent did not offer benefit in reducing the complication rate over sutures over a bolster. PMID:29410886

  6. Comparison of postural sway depending on balance pad type

    PubMed Central

    Lee, DongGeon; Kim, HaNa; An, HyunJi; Jang, JiEun; Hong, SoungKyun; Jung, SunHye; Lee, Kyeongbong; Choi, Myong-Ryol; Lee, Kyung-Hee; Lee, GyuChang

    2018-01-01

    [Purpose] The purpose of the present study was to compare the postural sway of healthy adults standing on different types of balance pads. [Subjects and Methods] Nine healthy adults participated in this study. Postural body sway was measured while participants were standing on four different types of balance pads: Balance-pad Elite (BE), Aero-Step XL (AS), Dynair Ballkissen Senso (DBS), and Dynair Ballkissen XXL Meditation and Yoga (DBMY). A Wii Balance Board interfaced with Balancia software was used to measure postural body sway. [Results] In the sway velocity, sway path length, and sway area, no significant differences were found between baseline conditions (participants were standing on the floor with no balance pad) and the use of the BE or AS. However, significant increases in all parameters were found comparing baseline conditions to the use of either Dynair balance pad. Furthermore, the use of either Dynair balance pad significantly increased postural sway compared to both the BE and the AS. [Conclusion] These findings suggest that the DBS and DBMY balance pads may serve as superior tools for providing unstable condition for balance training than the BE and the AS balance pads. PMID:29545688

  7. Comparison of postural sway depending on balance pad type.

    PubMed

    Lee, DongGeon; Kim, HaNa; An, HyunJi; Jang, JiEun; Hong, SoungKyun; Jung, SunHye; Lee, Kyeongbong; Choi, Myong-Ryol; Lee, Kyung-Hee; Lee, GyuChang

    2018-02-01

    [Purpose] The purpose of the present study was to compare the postural sway of healthy adults standing on different types of balance pads. [Subjects and Methods] Nine healthy adults participated in this study. Postural body sway was measured while participants were standing on four different types of balance pads: Balance-pad Elite (BE), Aero-Step XL (AS), Dynair Ballkissen Senso (DBS), and Dynair Ballkissen XXL Meditation and Yoga (DBMY). A Wii Balance Board interfaced with Balancia software was used to measure postural body sway. [Results] In the sway velocity, sway path length, and sway area, no significant differences were found between baseline conditions (participants were standing on the floor with no balance pad) and the use of the BE or AS. However, significant increases in all parameters were found comparing baseline conditions to the use of either Dynair balance pad. Furthermore, the use of either Dynair balance pad significantly increased postural sway compared to both the BE and the AS. [Conclusion] These findings suggest that the DBS and DBMY balance pads may serve as superior tools for providing unstable condition for balance training than the BE and the AS balance pads.

  8. Breast pads: their effectiveness and use by lactating women.

    PubMed

    Griffiths, R J

    1993-03-01

    The diversity of breast pads available and absence of data on their effectiveness led the Breastfeeding Association of South Africa to design laboratory simulation experiments measuring fluid retention and evaporative properties as indicators of pad surface dryness. Questionnaires distributed at four breastfeeding clinics were used to obtain data on mothers' use of pads and incidence of breast problems. The majority of mothers surveyed used a new disposable breast pad made by Johnson & Johnson. The experimental studies showed that this pad allowed no leaking and kept the breast markedly drier than other disposables. Exclusive use of these pads or cotton towelling pads did not produce a detectable increase in nipple problems. A home-made disposable breast pad using a nappy (diaper) liner encasing toilet paper was most effective at keeping the breast dry and offered good protection against leaking. Since it is economical and easy to use, it is recommended as a good alternative to expensive disposables. Clinging materials, e.g. gauze, cottonwool or paper, and panty liners, maintain excessive surface dampness and are not recommended. If used, two layers of nappy liner on the inner surface may enhance nipple dryness.

  9. The prevalence of peripheral arterial disease (PAD) and PAD risk factors among different ethnic groups in the US population.

    PubMed

    Aponte, Judith

    2012-06-01

    The National Health and Nutrition Examination Survey (NHANES) 2003-2004 data set was utilized to examine and compare trends and differences in PAD-related risk factor variables among 5 different ethnic/racial groups. The sample included individuals 40 years and older with PAD and of the ethnic/racial groups: Mexican American, Other Hispanic, Non-Hispanic White, Non-Hispanic Black, and Other/Multiracial. Two demographic variables (age and gender) and 4 PAD-risk factors (hypertension [HTN], systolic blood pressure [SBP], and diastolic blood pressure [DBP]), dyslipidemia, high-density lipoprotein [HDL] and low-density lipoprotein [LDL], diabetes, and cigarette smoking) were examined for each group. The study design conducted was descriptive using the NHANES 2003-2004 secondary data set. Raw data were weighted. Descriptive statistics were measured, Chi-squares were compared, and Phi-coefficients were measured for association using SAS version 9.1 and SUDAAN 10.0. The group with the highest prevalence of PAD are females 40-50 years of age, and the ethnic group with PAD who have the highest risk for PAD-related risk factors are Non-Hispanic Black. Through Chi-square significant differences (P=0.00001-0.03874) between specific ethnic groups for all four PAD-related risk factors (i.e., HTN, dyslipidemia, diabetes and cigarette smoking). All of the associations between the prevalence of HTN, dyslipidemia, diabetes, or cigarette smoking and ethnicity were statistically significant (P=<0.0001). Overall differences exist among the different ethnic groups. Copyright © 2012 Society for Vascular Nursing, Inc. Published by Mosby, Inc. All rights reserved.

  10. Using iPad2 for a Graduate Practicum Course

    ERIC Educational Resources Information Center

    Sachs, Lindsey; Bull, Prince Hycy

    2012-01-01

    iPads and iPhones continue to impact academia, but the iPad2 provides features that could enhance teacher education programs. This paper addresses how eight graduate students and a faculty used iPad2 to support a graduate practicum course. Participants were asked to report how they used their iPad2 each week in the form of a written log and…

  11. Newer Hemostatic Agents Used in the Practice of Dermatologic Surgery

    PubMed Central

    Brewer, Jerry D.

    2013-01-01

    Minor postoperative bleeding is the most common complication of cutaneous surgery. Because of the commonality of this complication, hemostasis is an important concept to address when considering dermatologic procedures. Patients that have a bleeding diathesis, an inherited/acquired coagulopathy, or who are on anticoagulant/antiplatelet medications pose a greater risk for bleeding complications during the postoperative period. Knowledge of these conditions preoperatively is of the utmost importance, allowing for proper preparation and prevention. Also, it is important to be aware of the various hemostatic modalities available, including electrocoagulation, which is among the most effective and widely used techniques. Prompt recognition of hematoma formation and knowledge of postoperative wound care can prevent further complications such as wound dehiscence, infection, or skin-graft necrosis, minimizing poor outcomes. PMID:23997764

  12. Hemostatic, antibacterial biopolymers from Acacia arabica (Lam.) Willd. and Moringa oleifera (Lam.) as potential wound dressing materials.

    PubMed

    Bhatnagar, Monica; Parwani, Laxmi; Sharma, Vinay; Ganguli, Jhuma; Bhatnagar, Ashish

    2013-10-01

    Acacia arabica and Moringa oleifera are credited with a number of medicinal properties. Traditionally gum of Acacia plant is used in the treatment of skin disorders to soothe skin rashes, soreness, inflammation and burns while Moringa seed extracts are known to have antibacterial activity. In the present study the potential of the polymeric component of aqueous extracts of gum acacia (GA) and the seeds of M. oleifera (MSP) in wound management was evaluated. The results revealed that both biopolymers were hemostatic and hasten blood coagulation. They showed shortening of activated partial thromboplastin time and prothrombin time and were non-cytotoxic in nature. Both showed antibacterial activity against organisms known to be involved in wound infections with MIC ranging from 500-600 microg mL(-1) for GA and 300-700 microg mL(-1) for MSP. They were biodegradable and exhibited water absorption capacity in the range of 415 to 935%. The hemostatic character coupled to these properties envisions their potential in preparation of dressings for bleeding and profusely exuding wounds. The biopolymers have been further analysed for their composition by Gas chromatography.

  13. iPads in Higher Education--Hype and Hope

    ERIC Educational Resources Information Center

    Nguyen, Lemai; Barton, Siew Mee; Nguyen, Linh Thuy

    2015-01-01

    This paper systematically reviews current research on using iPads in the higher education sector. Since the release of iPads by Apple in 2010, this new technology has been quickly adopted everywhere, especially by the younger generation and professionals. We were motivated to find out how iPads have been adopted for use in the higher education…

  14. Effects of two combined oral contraceptives containing ethinyl estradiol 20 microg combined with either drospirenone or desogestrel on lipids, hemostatic parameters and carbohydrate metabolism.

    PubMed

    Klipping, Christine; Marr, Joachim

    2005-06-01

    To compare the effect of ethinyl estradiol 20 microg/drospirenone 3 mg (EE 20 microg/DRSP 3 mg) administered according to a 24/4 regimen with ethinyl estradiol 20 microg/desogestrel 150 microg (EE 20 microg/DSG 150 microg) administered according to the conventional 21/7 regimen on lipid, carbohydrate and hemostatic parameters. In this open-label study, healthy women were randomized to EE 20 microg/DRSP 3 mg or EE 20 microg/DSG 150 microg for seven cycles. Mean differences in high-density lipoprotein (HDL)- and low-density lipoprotein (LDL)-cholesterol levels at cycle 7 compared to baseline were assessed. Secondary variables included changes in other lipid, hemostatic and carbohydrate parameters. Both treatments increased HDL-cholesterol, but decreased LDL-cholesterol by a comparable extent. Although slightly elevated in both groups, blood glucose and C-peptide levels measured during oral glucose tolerance tests were within normal reference ranges at cycle 7. Overall, the differences in lipid, hemostatic or carbohydrate parameters were not significant between the two treatments. EE 20 microg/DRSP 3 mg has a good safety profile comparable with EE 20 microg/DSG 150 microg.

  15. Binocular iPad treatment for amblyopia in preschool children

    PubMed Central

    Birch, Eileen E.; Li, Simone L.; Jost, Reed M.; Morale, Sarah E.; De La Cruz, Angie; Stager, David; Dao, Lori; Stager, David R.

    2014-01-01

    Background Recent experimental evidence supports a role for binocular visual experience in the treatment of amblyopia. The purpose of this study was to determine whether repeated binocular visual experience with dichoptic iPad games could effectively treat amblyopia in preschool children. Methods A total of 50 consecutive amblyopic preschool children 3–6.9 years of age were assigned to play sham iPad games (first 5 children) or binocular iPad games (n = 45) for at least 4 hours per week for 4 weeks. Thirty (67%) children in the binocular iPad group and 4 (80%) in the sham iPad group were also treated with patching at a different time of day. Visual acuity and stereoacuity were assessed at baseline, at 4 weeks, and at 3 months after the cessation of game play. Results The sham iPad group had no significant improvement in visual acuity (t4 = 0.34, P = 0.75). In the binocular iPad group, mean visual acuity (plus or minus standard error) improved from 0.43 ± 0.03 at baseline to 0.34 ± 0.03 logMAR at 4 weeks (n = 45; paired t44 = 4.93; P < 0.0001). Stereoacuity did not significantly improve (t44 = 1.35, P = 0.18). Children who played the binocular iPad games for ≥8 hours (≥50% compliance) had significantly more visual acuity improvement than children who played 0–4 hours (t43 = 4.21, P = 0.0001). Conclusions Repeated binocular experience, provided by dichoptic iPad game play, was more effective than sham iPad game play as a treatment for amblyopia in preschool children. PMID:25727578

  16. Effects of Chitin and Sepia Ink Hybrid Hemostatic Sponge on the Blood Parameters of Mice

    PubMed Central

    Zhang, Wei; Sun, Yu-Lin; Chen, Dao-Hai

    2014-01-01

    Chitin and sepia ink hybrid hemostatic sponge (CTSH sponge), a new biomedical material, was extensively studied for its beneficial biological properties of hemostasis and stimulation of healing. However, studies examining the safety of CTSH sponge in the blood system are lacking. This experiment aimed to examine whether CTSH sponge has negative effect on blood systems of mice, which were treated with a dosage of CTSH sponge (135 mg/kg) through a laparotomy. CTSH sponge was implanted into the abdominal subcutaneous and a laparotomy was used for blood sampling from abdominal aortic. Several kinds of blood parameters were detected at different time points, which were reflected by coagulation parameters including thrombin time (TT), prothrombin time (PT), activated partial thromboplatin time (APTT), fibrinogen (FIB) and platelet factor 4 (PF4); anticoagulation parameter including antithrombin III (AT-III); fibrinolytic parameters including plasminogen (PLG), fibrin degradation product (FDP) and D-dimer; hemorheology parameters including blood viscosity (BV) and plasma viscosity (PV). Results showed that CTSH sponge has no significant effect on the blood parameters of mice. The data suggested that CTSH sponge can be applied in the field of biomedical materials and has potential possibility to be developed into clinical drugs of hemostatic agents. PMID:24727395

  17. Adsorption of tranexamic acid on hydroxyapatite: Toward the development of biomaterials with local hemostatic activity.

    PubMed

    Sarda, Stéphanie; Errassifi, Farid; Marsan, Olivier; Geffre, Anne; Trumel, Catherine; Drouet, Christophe

    2016-09-01

    This work proposes to combine tranexamic acid (TAX), a clinically used antifibrinolytic agent, and hydroxyapatite (HA), widely used in bone replacement, to produce a novel bioactive apatitic biomaterial with intrinsic hemostatic properties. The aim of this study was to investigate adsorptive behavior of the TAX molecule onto HA and to point out its release in near physiological conditions. No other phase was observed by X-ray diffraction or transmission electron microscopy, and no apparent change in crystal size was detected. The presence of TAX on the powders was lightly detected on Raman spectra after adsorption. The adsorption data could be fitted with a Langmuir-Freundlich equation, suggesting a strong interaction between adsorbed molecules and the formation of multilayers. The concentration of calcium and phosphate ions in solution remained low and stable during the adsorption process, thus ion exchange during the adsorption process could be ruled out. The release of TAX was fast during the first hours and was governed by a complex process that likely involved both diffusion and dissolution of HA. Preliminary aPTT (activated partial thromboplastin time) hemostasis tests offered promising results for the development of osteoconductive apatitic biomaterials with intrinsic hemostatic properties, whether for dental or orthopedic applications. Copyright © 2016. Published by Elsevier B.V.

  18. Using iPads to Your Advantage

    ERIC Educational Resources Information Center

    Zakrzewski, Jennifer L.

    2016-01-01

    In this article, middle school mathematics teacher Jennifer Zakrzewski describes how she successfully incorporated iPads and Apple TV (for projection of iPad screens) into her classroom while having her students solve a problem about mangoes. As Zakrzewski began a unit on multiplying and dividing fractions, she chose to start with the Mangoes…

  19. Resident iPad use: has it really changed the game?

    PubMed

    Berkowitz, Seth J; Kung, Justin W; Eisenberg, Ronald L; Donohoe, Kevin; Tsai, Leo L; Slanetz, Priscilla J

    2014-02-01

    The purpose of this study was to assess residents' usage patterns and opinions of the iPad as a tool for radiology education and clinical practice at an academic medical center. All 38 radiology residents in our radiology program (postgraduate years 2 to 5) were provided with iPad 2 tablets and subscriptions to e-Anatomy and STATdx. After 6 months of device use, residents were surveyed to assess their opinions regarding the technology as a tool for education and clinical practice. A total of 36 residents (95%) completed the survey. Eighty-six percent reported daily iPad use. Radiology-specific applications, particularly e-Anatomy, were used weekly or daily by 88% of respondents. Most preferred to read journal articles on the iPad (70%), but the number of respondents preferring to read textbooks on the iPad (48.5%) compared with the traditional bound form (48.5%) was evenly divided. Residents were also divided on the clinical utility of the iPad. Most had not used the iPad to view radiologic examinations (75%). Fewer than half (47%) used their iPads during readout. Finally, only 12% had used the iPad to edit dictated reports. The iPad has generated excitement within the radiology community, particularly among resident educators, who are increasingly recognizing the unique needs of "millennial learners." This study showed that the majority of residents at the authors' institution have incorporated the iPad as an educational tool and use it as a learning aid. Incorporation of the iPad into clinical workflow has been less pronounced. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  20. Day care PNL using ‘Santosh-PGI hemostatic seal’ versus standard PNL: A randomized controlled study

    PubMed Central

    Singh, Shivanshu; Singh, Prashant; Singh, Shrawan Kumar

    2016-01-01

    Introduction To compare the outcomes of tubeless day care PNL using hemostatic seal in the access tract versus standard PNL. Material and methods It was a prospective randomized controlled study. Cases were randomized to either the day care group with hemostatic seal (DCS) or the control group where patients were admitted and a nephrostomy tube was placed at the conclusion of surgery. Results A total of 180 cases were screened and out of these, 113 were included in the final analysis. The stone clearance rates were comparable in both the groups. The mean drop in hemoglobin was significantly lower in DCS group than the control group (1.05 ±0.68 vs. 1.30 ±0.58 gm/dl, p = 0.038).Mean postoperative pain score, analgesic requirement (paracetamol) and duration of hospital stay were also significantly lower in the DCS group (3.79 ±1.23 vs. 6.12 ±0.96, 1.48 ±0.50 vs. 4.09 ±1.11 grams and 0.48 ±0.26 vs. 4.74 ±1.53 days respectively; p <0.05). The incidence of urine leakage through the access tract site was significantly lower in the DCS subgroup when compared to the controls (3.6% vs. 21.1%, p <0.05). Cases in the DCS group resumed their normal activities in a significantly shorter time (8.05 ±3.05 vs.18.42 ±4.42 days; p <0.05). Higher proportion of cases in the DCS group got re-admitted, although it was not a statistically significant number (7.1% vs. 1.8%; p = 0.21). Conclusions Tubeless day care PNL with composite hemostatic tract seal is considered safe. It resulted in a significant reduction of blood loss and analgesic requirement with significantly reduced hospital stay, nephrostomy tube site morbidity and time required to resume normal activity when compared to the standard PNL. However, patients must be compliant with the given instructions and should have access to a health care facility, as few of them may need re-admission. PMID:27551557

  1. Learning Chinese Idioms through iPads

    ERIC Educational Resources Information Center

    Yang, Chunsheng; Xie, Ying

    2013-01-01

    This paper reports on an action research study using iPads during the teaching of Chinese idioms to heritage learners. A class of 12 second-year Chinese learners were engaged in a self-generated learning process focused on learning abstract and concrete idioms using iPads. Students' short-term and long-term learning was measured; feedback from a…

  2. Gallium nitrate induces fibrinogen flocculation: an explanation for its hemostatic effect?

    PubMed

    Bauters, A; Holt, D J; Zerbib, P; Rogosnitzky, M

    2013-12-01

    A novel hemostatic effect of gallium nitrate has recently been discovered. Our aim was to perform a preliminary investigation into its mode of action. Thromboelastography® showed no effect on coagulation but pointed instead to changes in fibrinogen concentration. We measured functional fibrinogen in whole blood after addition of gallium nitrate and nitric acid. We found that gallium nitrate induces fibrinogen precipitation in whole blood to a significantly higher degree than solutions of nitric acid alone. This precipitate is not primarily pH driven, and appears to occur via flocculation. This behavior is in line with the generally observed ability of metals to induce fibrinogen precipitation. Further investigation is required into this novel phenomenon.

  3. Pad Safety Personnel Launch Support For STS-200

    NASA Technical Reports Server (NTRS)

    Guarino, Jennifer

    2007-01-01

    The launch of a space shuttle is a complex and lengthy procedure. There are many places and components to look at and prepare. The components are the orbiter, solid rocket boosters, external tank, and ground equipment. Some of the places are the launch pad, fuel locations, and surrounding structures. Preparations for a launch include equipment checks, system checks, sniff checks for hazardous commodities, and countless walkdowns. Throughout these preparations, pad safety personnel must always be on call. This requires three shifts of multiple people to be ready when needed. Also, the pad safety personnel must be available for the non-launch tasks that are always present for both launch pads

  4. iPads in Breast Imaging – A Phantom Study

    PubMed Central

    Hammon, M.; Schlechtweg, P. M.; Schulz-Wendtland, R.; Uder, M.; Schwab, S. A.

    2014-01-01

    Introduction: Modern tablet PCs as the iPad are becoming more and more integrated into medicine. The aim of this study was to evaluate the display quality of iPads regarding digital mammography. Materials and Methods: Three experienced readers compared the display quality of the iPad 2 and 3 with a dedicated 10 megapixel (MP) mammography liquid crystal display (LCD) screen in consensus using the standardized Contrast Detail Mammography (CDMAM) phantom. Phantom fields without agreement between the readers were classified as “uncertain”, correct 2 : 1 decisions were classified as “uncertain/readable”. In a second step display quality of the three reading devices was judged subjectively in a side by side comparison. Results: The 10 MP screen was superior to both iPads in 4 (phantom-)fields and inferior in 2 fields. Comparing the iPads, version 3 was superior in 4 fields and version 2 was superior in 1 field. However these differences were not significant. Total number of “uncertain” fields did not show significant differences. The number of “uncertain” fields was 15 with the 10 MP screen, 16 with the iPad 2 and 17 with the iPad 3 (p > 0.05), the number of “uncertain/readable” fields was 4, 7 and 8, respectively. Subjective image quality of the iPad 3 and the 10 MP screen was rated superior to the iPad 2. Conclusion: The evaluated iPads, especially in version 3, seem to be adequate to display mammograms in a diagnostic quality and thus could be useful e.g. for patient consultation, clinical demonstration or educational and teaching purposes. However primary mammogram reading should still be performed on dedicated large sized reading screens. PMID:24741126

  5. A Protection And Detection Surface (PADS) for damage tolerance

    NASA Technical Reports Server (NTRS)

    Shuart, M. J.; Prasad, C. B.; Biggers, S. B.

    1990-01-01

    A protection and detection surface (PADS) concept was studied for application to composite primary aircraft structures. A Kevlar-epoxy woven face sheet with a Rohacell foam core was found to be the most effective PADS configuration among the configurations evaluated. The weight of the PADS configuration was estimated to be approximately 17 percent of the structural weight. The PADS configuration was bonded to graphite-epoxy base laminates, and up to a 70 percent improvement in compression-after-impact failure strains was observed.

  6. A Protection And Detection Surface (PADS) for damage tolerance

    NASA Technical Reports Server (NTRS)

    Shuart, Mark J.; Prasad, Chunchu B.; Biggers, Sherrill B.

    1990-01-01

    A protection and detection surface (PADS) concept was studied for application to composite primary aircraft structures. A Kevlar-epoxy woven face sheet with a Rohacell foam core was found to be the most effective PADS configuration among the configurations evaluated. The weight of the PADS configuration was estimated to be approximately 17 pct of the structural weight. The PADS configuration was bonded to graphite-epoxy base laminates, and up to a 70 pct improvement in compression-after-impact failure strains was observed.

  7. Comparative Study of the Effects of Combined Oral Contraceptives in Hemostatic Variables

    PubMed Central

    Stocco, Bianca; Fumagalli, Helen F.; Franceschini, Silvio A.; Martinez, Edson Z.; Marzocchi-Machado, Cleni M.; de Sá, Marcos Felipe S.; Toloi, Maria Regina T.

    2015-01-01

    Abstract Thrombotic risk is associated with the estrogen dose and type of progestin in combined oral contraceptives. Studies published since 1990 showed that third-generation progestins have larger risk to contribute to thrombosis development than the second-generation. However, there are conflicts in the literature regarding the thrombotic risk associated to the drospirenone progestin. So, this study aimed to evaluate the effects of 3 formulations of contraceptives containing ethinylestradiol (EE) (20 and 30 μg) combined with drospirenone versus levonorgestrel combined with EE (30 μg) in hemostatic parameters. This cross-sectional study included 70 healthy women between 18 and 30 years, BMI 19 to 30 kg/m2, not pregnant, non-smokers, and users or non-users (control) of contraceptives for a minimum period of 6 months. The following parameters were assessed: prothrombin time (PT), Factor VII, activated partial thromboplastin time (aPTT), Factor XII, fibrinogen, Factor 1 + 2, Protein C, Protein S, antithrombin, D-dimers, and plasminogen activator inhibitor-1. Significant alterations were found in PT, aPTT, fibrinogen, D-dimers, and protein S, all favoring a state of hypercoagulation for contraceptive containing DRSP/20EE. Both contraceptives containing DRSP/30EE and LNG/30EE promoted changes that favor the hypercoagulability in the coagulant variable PT and in the anticoagulant variables Protein S and Protein C, respectively. We suggest that the progestin drospirenone can contribute to an inadequate balance among procoagulant, anticoagulant, and fibrinolytic factors, since that the contraceptive containing the lowest dose of estrogen and drospirenone (DRSP/20EE) caused a higher number of hemostatic changes. PMID:25634167

  8. Treatment of Severe Aortic Bleeding Using Hemopatch in Swine on Dual Antiplatelet Therapy.

    PubMed

    Baumgartner, Bernhard; Draxler, Wolfgang; Lewis, Kevin M

    2016-12-01

    The perioperative management of patients on antithrombotic therapy is currently an unresolved problem as these therapies pose a considerable risk for perioperative hemorrhagic complications. The presented studies investigated the efficacy of a new collagen technology to achieve hemostasis. A polyethylene glycol-coated collagen pad (PCC) was compared to a marketed fibrinogen-thrombin coated collagen pad (FTC) for the treatment of an aortotomy incision in heparinized swine on dual antiplatelet therapy. Twenty-eight 3-mm aortotomy incisions were created in nine heparinized pigs without antiplatelet therapy and treated with PCC. Sixty-eight aortotomy incisions were created in ten heparinized pigs that received clopidogrel (10-11 mg/kg) and acetylsalicylic acid (8-11 mg/kg) orally for 5 days, and treated with either PCC or FTC (N = 34/group). Dual antiplatelet therapy resulted in significantly reduced platelet function. Aortotomy incisions resulted in life-threatening bleeding of 35-292 ml/min. In animals without antiplatelet treatment, PCC provided 96% immediate hemostatic success. In animals with antiplatelet treatment, FTC provided 18% immediate hemostatic success increasing to 74% after 10 min. Strikingly, PCC provided 94% immediate success increasing to 100% after 10 min. Controlling for differences in pretreatment bleeding rates, statistical model-estimated time to hemostasis was 12 times shorter in PCC-treated lesions (p < .02). The combination of a procoagulant collagen pad with a synthetic sealing component provides excellent hemostatic properties under a worst-case scenario. PCC rapidly and firmly adheres to tissue, thereby controlling severe arterial bleeding, even when platelet function is significantly reduced. Treatment with PCC provided superior time to hemostasis compared to FTC.

  9. Elastic modulus of tree frog adhesive toe pads.

    PubMed

    Barnes, W Jon P; Goodwyn, Pablo J Perez; Nokhbatolfoghahai, Mohsen; Gorb, Stanislav N

    2011-10-01

    Previous work using an atomic force microscope in nanoindenter mode indicated that the outer, 10- to 15-μm thick, keratinised layer of tree frog toe pads has a modulus of elasticity equivalent to silicone rubber (5-15 MPa) (Scholz et al. 2009), but gave no information on the physical properties of deeper structures. In this study, micro-indentation is used to measure the stiffness of whole toe pads of the tree frog, Litoria caerulea. We show here that tree frog toe pads are amongst the softest of biological structures (effective elastic modulus 4-25 kPa), and that they exhibit a gradient of stiffness, being stiffest on the outside. This stiffness gradient results from the presence of a dense network of capillaries lying beneath the pad epidermis, which probably has a shock absorbing function. Additionally, we compare the physical properties (elastic modulus, work of adhesion, pull-off force) of the toe pads of immature and adult frogs.

  10. Enter the iPad (or Not?)

    ERIC Educational Resources Information Center

    Waters, John K.

    2010-01-01

    Few computing devices have sparked the burning gizmo lust ignited by the iPad. Apple's latest entry into the tablet PC market didn't generate much heat when it was first unveiled in January, but by April 3, the day of the official release, feverish customers were mobbing Apple stores. The company claims to have sold 300,000 iPads by midnight on…

  11. IT Does Not Love iPads

    ERIC Educational Resources Information Center

    Fredette, Michelle

    2013-01-01

    On many campuses, iPads have taken over the hearts and minds of everyone. Everyone, that is, except the IT department. These sexy tablets might be the apple of faculty and students' eyes, but for IT directors and their staffs, working with iPads in an enterprise network environment is not the stuff of a love affair. To state the problem…

  12. Conservative management of post-partum hemorrhage secondary to placenta previa-accreta with hypogastric artery ligation and endo-uterine hemostatic suture.

    PubMed

    Rauf, Melekoglu; Ebru, Celik; Sevil, Eraslan; Selim, Buyukkurt

    2017-02-01

    The aim of this study was to investigate maternal and neonatal outcomes of conservative management of post-partum hemorrhage due to placenta previa-accreta using hypogastric artery ligation and endo-uterine hemostatic suture to lower uterine segment. The records of 38 patients who were managed conservatively with hypogastric artery ligation and endo-uterine hemostatic suture to control post-partum hemorrhage secondary to placenta previa-accreta between April 2014 and January 2016, were reviewed retrospectively. Placenta previa-accreta was diagnosed according to gray-scale, color and 3-D power Doppler ultrasonography in addition to the intraoperative findings based on fragmentary or difficult separation of the placenta. In the case of conservative treatment protocol failure, cesarean hysterectomy was performed. Of these patients, 55.2% were between 25 and 35 years old; 97.5% were multiparous; 71.2% had two or more previous cesarean section and 68.5% had preterm delivery. Women with placenta accreta had a median estimated blood loss of 450 mL; 57.8% of patients had blood transfusion (mean intraoperative transfusion, 2 units packed red blood cells; range, 0-9 units). Median duration of operation was 112.5 min (range, 45-305 min) and 32 patients (84.3%) with placenta accreta did not undergo cesarean hysterectomy. Conservative treatment of post-partum hemorrhage secondary to placenta previa-accreta with hypogastric artery ligation and endo-uterine hemostatic sutures to the lower segment of the uterus is associated with lower hysterectomy rate compared with the other conservative methods reported in the literature. © 2016 Japan Society of Obstetrics and Gynecology.

  13. Stability of hemostatic proteins in canine fresh-frozen plasma thawed with a modified commercial microwave warmer or warm water bath.

    PubMed

    Pashmakova, Medora B; Barr, James W; Bishop, Micah A

    2015-05-01

    To compare stability of hemostatic proteins in canine fresh-frozen plasma (FFP) thawed with a modified commercial microwave warmer (MCM) or warm water bath (37°C; WWB) or at room temperature (22°C). Fresh-frozen plasma obtained from 8 canine donors of a commercial blood bank. A commercial microwave warmer was modified with a thermocouple to measure surface temperature of bags containing plasma. The MCM and a WWB were each used to concurrently thaw a 60-mL bag of plasma obtained from the same donor. Two 3-mL control aliquots of FFP from each donor were thawed to room temperature without use of a heating device. Concentrations of hemostatic proteins, albumin, and D-dimers; prothrombin time (PT); and activated partial thromboplastin time (aPTT) were determined for all samples. Significant decreases in concentrations of factors II, IX, X, XI, fibrinogen, von Willebrand factor, antithrombin, protein C, and albumin and significant increases in PT and aPTT were detected for plasma thawed with the MCM, compared with results for samples thawed with the WWB. Concentrations of factors VII, VIII, and XII were not significantly different between plasma thawed with the MCM and WWB. Concentrations of D-dimers were above the reference range for all thawed samples regardless of thawing method. No significant differences in factor concentrations were detected between control and WWB-thawed samples. Significant differences in hemostatic protein concentrations and coagulation times were detected for plasma thawed with an MCM but not between control and WWB-thawed samples. Clinical importance of these changes should be investigated.

  14. Comparative Testing of New Hemostatic Agents in a Swine Model of Extremity Arterial and Venous Hemorrhage

    DTIC Science & Technology

    2010-01-01

    by the Institutional Animal Care and Use Committee and all animals received humane care in com- pliance with the Guide for the Care and Use of...diminished markedly in recent military operations, due to sev- eral factors including routine vi-ear of hody armor, judicious use of tourniquets for...extremity hemorrhage, rapid casualty evacuation, and aggressive use of blood products in hemor- rhagic shock.’’ Advanced hemostatic agents further reduce

  15. Associations between vitamin K status and hemostatic and inflammatory biomarkers in community-dwelling adults: The multi-ethnic study of atherosclerosis

    USDA-ARS?s Scientific Manuscript database

    Vitamin K is integral to hemostatic function, and in vitro and animal experiments suggest that vitamin K can suppress production of inflammatory cytokines. To test the hypothesis that higher vitamin K status is associated with lower hemostasic activation and inflammation in community-dwelling adults...

  16. Carbon-Nanotube-Carpet Heat-Transfer Pads

    NASA Technical Reports Server (NTRS)

    Li, Jun; Cruden, Brett A.; Cassel, Alan M.

    2006-01-01

    Microscopic thermal-contact pads that include carpet-like arrays of carbon nanotubes have been invented for dissipating heat generated in integrated circuits and similarly sized single electronic components. The need for these or other innovative thermal-contact pads arises because the requisite high thermal conductances cannot be realized by scaling conventional macroscopic thermal-contact pads down to microscopic sizes. Overcoming limitations of conventional thermal-contact materials and components, the carbon-nanotube thermal-contact pads offer the high thermal conductivities needed to accommodate the high local thermal power densities of modern electronic circuits, without need for large clamping pressures, extreme smoothness of surfaces in contact, or gap-filling materials (e.g., thermally conductive greases) to ensure adequate thermal contact. Moreover, unlike some conventional thermal-contact components, these pads are reusable. The figure depicts a typical pad according to the invention, in contact with a rough surface on an electronic component that is to be cooled. Through reversible bending and buckling of carbon nanotubes at asperities on the rough surface, the pad yields sufficiently, under relatively low contact pressure, that thermal contact is distributed to many locations on the surface to be cooled, including valleys where contact would not ordinarily occur in conventional clamping of rigid surfaces. Hence, the effective thermal-contact area is greater than that achievable through scaling down of a macroscopic thermal-contact pad. The extremely high longitudinal thermal conductivities of the carbon nanotubes are utilized to conduct heat away from potential hot spots on the surface to be cooled. The fibers protrude from a layer of a filler material (Cu, Ag, Au, or metal-particle- filled gels), which provides both mechanical support to maintain the carbon nanotubes in alignment and thermal conductivity to enhance the diffusion of concentrated heat

  17. Stretchable touch-sensing skin over padding for co-robots

    NASA Astrophysics Data System (ADS)

    Chen, Ying; Yu, Miao; Bruck, Hugh A.; Smela, Elisabeth

    2016-05-01

    For robots that work collaboratively with people, often referred to as ‘co-robots’, it would be beneficial for them to be soft or padded and to have a touch-sensing ‘skin’ to enable tactile environmental awareness. However, a sensing skin over a padding material that undergoes large deformations requires ‘stretchable’ materials, which may possess time-dependent or viscoelastic mechanical responses. In this work the roles that a padding layer plays when placed under a stretchable sensing layer was investigated. A strain-sensing skin was formed by coating a thin film of compliant piezoresistive sensing paint, consisting of exfoliated graphite in latex, onto a rubber membrane, and the response of the skin was characterized. The change in resistance was linear with tensile strain. The role of the padding material was then investigated under indentation by examining three foams and two elastomers. As expected, the padding enhanced energy dissipation as shown by hysteresis in the sensor response, which is linked to its protective function; the hysteresis was comparable for the five padding materials. The padding also provided an unexpected advantage: it magnified the change in resistance compared to that obtained under free displacement in air. While hysteresis in viscoelastic materials can largely be handled with an appropriate model, inconsistency cannot be, and the two elastomers were found to have unacceptably high variability because of micro-cracks and other defects in these materials. On the other hand, foams that had few defects and regular cell sizes gave good consistency across trials and different sensor positions over the padding. Combined with their lighter weight and availability in a wide range of stiffness, we conclude that foams make a better choice for padding of co-robots.

  18. Evolution of multi-well pad development and influence of well pads on environmental violations and wastewater volumes in the Marcellus shale (USA).

    PubMed

    Manda, Alex K; Heath, Jamie L; Klein, Wendy A; Griffin, Michael T; Montz, Burrell E

    2014-09-01

    A majority of well pads for unconventional gas wells that are drilled into the Marcellus shale (northeastern USA) consist of multiple wells (in some cases as many as 12 wells per pad), yet the influence of the evolution of well pad development on the extent of environmental violations and wastewater production is unknown. Although the development of multi-well pads (MWP) at the expense of single well pads (SWP) has been mostly driven by economic factors, the concentrated nature of drilling activities from hydraulic fracturing and horizontal drilling operations on MWP suggests that MWP may create less surface disturbance, produce more volumes of wastewater, and generate more environmental violations than SWP. To explore these hypotheses, we use geospatial techniques and statistical analyses (i.e., regression and Mann-Whitney tests) to assess development of unconventional shale gas wells, and quantify environmental violations and wastewater volumes on SWP and MWP in Pennsylvania. The analyses include assessments of the influence of different types of well pads on potential, minor and major environmental events. Results reveal that (a) in recent years, a majority of pads on which new wells for unconventional gas were drilled are MWP, (b) on average, MWP have about five wells located on each pad and thus, had the transition to MWP not occurred, between two and four times as much land surface disturbance would have occurred per year if drilling was relegated to SWP, (c) there were more environmental violations on MWP than SWP, but when the number of wells were taken into account, fewer environmental violations per well were observed on MWP than on SWP, (d) there were more wastewater and recycled wastewater volumes per pad and per well produced on MWP than on SWP, and (e) the proportion of wastewater that was recycled was higher on MWP than SWP. This study sheds light on how the evolution from SWP to MWP has influenced environmental violations and wastewater production

  19. Hemostatic effects of a novel estradiol-based oral contraceptive: an open-label, randomized, crossover study of estradiol valerate/dienogest versus ethinylestradiol/levonorgestrel.

    PubMed

    Klipping, Christine; Duijkers, Ingrid; Parke, Susanne; Mellinger, Uwe; Serrani, Marco; Junge, Wolfgang

    2011-01-01

    A novel estradiol-based combined oral contraceptive (COC) is currently available in many countries worldwide, including Europe and the US. Based on previous studies, it is expected that this estradiol-based COC will have a reduced hepatic effect compared with COCs containing ethinylestradiol with regard to proteins controlling the hemostatic balance. The aim of this study was to compare the hemostatic effects of the estradiol valerate/dienogest COC with a monophasic low-estrogen dose COC containing ethinylestradiol/levonorgestrel. Healthy women aged 18-50 years were randomized to receive a COC containing estradiol valerate/dienogest (2 days estradiol valerate 3 mg, 5 days estradiol valerate 2 mg/dienogest 2 mg, 17 days estradiol valerate 2 mg/dienogest 3 mg, 2 days estradiol valerate 1 mg, 2 days placebo) or ethinylestradiol 0.03 mg/levonorgestrel 0.15 mg in a crossover study design. Women received each treatment for three cycles, with two washout cycles between treatments. The primary efficacy variables were the intra-individual absolute changes in prothrombin fragment 1 + 2 and D-dimer from baseline to cycle three. Data from 29 women were assessed. Intra-individual absolute changes in prothrombin fragment 1 + 2 and D-dimer from baseline to cycle three were less pronounced with estradiol valerate/dienogest than with ethinylestradiol/levonorgestrel. The novel COC containing estradiol valerate/dienogest had similar or less pronounced effects on hemostatic parameters than ethinylestradiol/levonorgestrel.

  20. Role of peptidylarginine deiminase 2 (PAD2) in mammary carcinoma cell migration.

    PubMed

    Horibata, Sachi; Rogers, Katherine E; Sadegh, David; Anguish, Lynne J; McElwee, John L; Shah, Pragya; Thompson, Paul R; Coonrod, Scott A

    2017-05-26

    Penetration of the mammary gland basement membrane by cancer cells is a crucial first step in tumor invasion. Using a mouse model of ductal carcinoma in situ, we previously found that inhibition of peptidylarginine deiminase 2 (PAD2, aka PADI2) activity appears to maintain basement membrane integrity in xenograft tumors. The goal of this investigation was to gain insight into the mechanisms by which PAD2 mediates this process. For our study, we modulated PAD2 activity in mammary ductal carcinoma cells by lentiviral shRNA-mediated depletion, lentiviral-mediated PAD2 overexpression, or PAD inhibition and explored the effects of these treatments on changes in cell migration and cell morphology. We also used these PAD2-modulated cells to test whether PAD2 may be required for EGF-induced cell migration. To determine how PAD2 might promote tumor cell migration in vivo, we tested the effects of PAD2 inhibition on the expression of several cell migration mediators in MCF10DCIS.com xenograft tumors. In addition, we tested the effect of PAD2 inhibition on EGF-induced ductal invasion and elongation in primary mouse mammary organoids. Lastly, using a transgenic mouse model, we investigated the effects of PAD2 overexpression on mammary gland development. Our results indicate that PAD2 depletion or inhibition suppresses cell migration and alters the morphology of MCF10DCIS.com cells. In addition, we found that PAD2 depletion suppresses the expression of the cytoskeletal regulatory proteins RhoA, Rac1, and Cdc42 and also promotes a mesenchymal to epithelial-like transition in tumor cells with an associated increase in the cell adhesion marker, E-cadherin. Our mammary gland organoid study found that inhibition of PAD2 activity suppresses EGF-induced ductal invasion. In vivo, we found that PAD2 overexpression causes hyperbranching in the developing mammary gland. Together, these results suggest that PAD2 plays a critical role in breast cancer cell migration. Our findings that EGF

  1. Pilot Study of iPad Incorporation Into Graduate Medical Education.

    PubMed

    Lobo, Mark J; Crandley, Edwin F; Rumph, Jake S; Kirk, Susan E; Dunlap, Neal E; Rahimi, Asal S; Turner, A Benton; Larner, James M; Read, Paul W

    2013-03-01

    Increased documentation and charting requirements are challenging for residents, given duty hour limits. Use of mobile electronic devices may help residents complete these tasks efficiently. To collect initial data on usage rates, information technology (IT) support requirements, and resident use of iPads during training. In this pilot study, we provided 12 residents/fellows from various specialties at the University of Virginia with an iPad with IT support. The system used a virtual private network with access to the institution's electronic health record. Participants were allowed to develop their own methods and systems for personalized iPad use, and after 9 months they provided data on the utility of the iPad. Feedback from the IT team also was obtained. Average iPad use was 2.1 h/d (range, 0.5-6 h/d). The average self-reported reduction in administrative work due to the iPad was 2.7 h/wk (range, 0-9 h/wk). A total of 75% (9 of 12) of the users would recommend universal adoption among residents and fellows. More than 90% (11 of 12) of users reported the iPad would improve communication for coordination of care. A total of 68% (8 of 12) of users reported that an iPad facilitated their activities as educators of medical students and junior residents. Residents cited slow data entry into the electronic health record and hospital areas lacking Wi-Fi connectivity as potential drawbacks to iPad use. The IT team reported minimal support time for device setup, maintenance, and upgrades, and limited security risks. The iPad may contribute to increased clinical efficiency, reduced hours spent on administrative tasks, and enhanced educational opportunities for residents, with minimal IT support.

  2. The hemostatic effect study of Cirsium setosum on regulating α1-ARs via mediating norepinephrine synthesis by enzyme catalysis.

    PubMed

    Chang, Nianwei; Li, Yanmei; Zhou, Mengge; Gao, Jie; Hou, Yuanyuan; Jiang, Min; Bai, Gang

    2017-03-01

    Cirsium setosum (CS) is the aboveground part of Cephalanoplos segetum Kitam. Although it has been used as a hemostatic treatment for thousands of years and is still in use today, the mechanism of CS on regulating ARs is still not clear. In this study, we aimed to clarify the mechanism of CS on regulating ARs. We developed a simple method based on UPLC/Q-TOF MS combined adrenergic receptor dual-luciferase reporter assay systems for the rapid determination of active constituents in CS. The mechanism of tyramine, the main active component for regulating ARs, was further investigated by an in vitro norepinephrine biotransformation test and in vivo vaso activity tests. Two phenethylamine ARs regulators (tyramine and N-methyltyramine) in CS were characterized, and it was found that tyramine could induce vasoconstriction via regulation of α1-ARs by mediating norepinephrine synthesis. The hemostatic effect of CS is associated with tyramine and N-methyltyramine, via regulation of α1-ARs, and the mechanism of tyramine is related to mediating norepinephrine synthesis by enzyme catalysis. Copyright © 2017. Published by Elsevier Masson SAS.

  3. One amino acid in mouse activated factor VII defines its endothelial protein C receptor (EPCR) binding and modulates its EPCR-dependent hemostatic activity in vivo.

    PubMed

    Pavani, G; Zintner, S M; Ivanciu, L; Small, J C; Stafford, K A; Szeto, J H; Margaritis, P

    2017-03-01

    Essentials The lack of factor (F) VIIa-endothelial protein C receptor (EPCR) binding in mice is unresolved. A single substitution of Leu4 to Phe in mouse FVIIa (mFVIIa) enables its interaction with EPCR. mFVIIa with a Phe4 shows EPCR binding-dependent enhanced hemostatic function in vivo vs. mFVIIa. Defining the FVIIa-EPCR interaction in mice allows for further investigating its biology in vivo. Background Human activated factor VII (hFVIIa), which is used in hemophilia treatment, binds to the endothelial protein C (PC) receptor (EPCR) with unclear hemostatic consequences. Interestingly, mice lack the activated FVII (FVIIa)-EPCR interaction. Therefore, to investigate the hemostatic consequences of this interaction in hemophilia, we previously engineered a mouse FVIIa (mFVIIa) molecule that bound mouse EPCR (mEPCR) by using three substitutions from mouse PC (mPC), i.e. Leu4→Phe, Leu8→Met, and Trp9→Arg. The resulting molecule, mFVIIa-FMR, modeled the EPCR-binding properties of hFVIIa and showed enhanced hemostatic capacity in hemophilic mice versus mFVIIa. These data implied a role of EPCR in the action of hFVIIa in hemophilia treatment. However, the substitutions in mFVIIa-FMR only broadly defined the sequence determinants for its mEPCR interaction and enhanced function in vivo. Objectives To determine the individual contributions of mPC Phe4, Met8 and Arg9 to the in vitro/in vivo properties of mFVIIa-FMR. Methods The mEPCR-binding properties of single amino acid variants of mFVIIa or mPC at position 4, 8 or 9 were investigated. Results and conclusions Phe4 in mFVIIa or mPC was solely critical for interaction with mEPCR. In hemophilic mice, administration of mFVIIa harboring a Phe4 resulted in a 1.9-2.5-fold increased hemostatic capacity versus mFVIIa that was EPCR binding-dependent. This recapitulated previous observations made with triple-mutant mFVIIa-FMR. As Leu8 is crucial for hFVIIa-EPCR binding, we describe the sequence divergence of this interaction in

  4. Silicon nanoparticle-functionalized fiberglass pads for sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mantey, Kevin; Nayfeh, Munir H.; Al-Hreish, Bahjat

    2011-03-15

    We used wet treatment to immobilize luminescent silicon nanoparticles on industrial glass fibers to impart optical and chemical functions to the fiber. Carpets or pads consisting of thousands of fibers are processed in parallel, enhancing the sensitivity of detection and the sampled volume. Treated pads exhibit strong luminescence, characteristic of the luminescence of the particles; showing no shift, broadening, or reduction of quantum efficiency. We demonstrate that drawing material by the pad due to physical adsorption can be reversed. We also demonstrate that allylamine can be covalently attached by photoinduced irradiation reactions, which results in imprinting the amine emission spectrum,more » providing spectral recognition. The imprint accompanied with a blue-shifting of the luminescence spectrum of the probe, allowing examination of the effect of termination on the nanoparticle structure. The shift is found to be consistent with an increase in the bandgap of the Si nanoparticle and is consistent with Quantum Monte Carlo calculations. In addition to sampling, the nano probe pad has the potential to enable a variety of biomedical applications through subsequent attachment.« less

  5. Analysis of an all-metallic resilient-pad gas-lubricated thrust bearing

    NASA Technical Reports Server (NTRS)

    Anderson, W. J.

    1974-01-01

    A resilient-pad gas thrust bearing that does not contain any elastomers in the bearing assembly is described and analyzed. The bearing consists of sector-shaped pads mounted asymmetrically on resilient foil beams. The effects of bearing design parameters on performance are shown. Performance of a resilient-pad bearing is compared with that of a pivoted-pad bearing.

  6. 16 CFR 300.23 - Linings, paddings, stiffening, trimmings and facings.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Linings, paddings, stiffening, trimmings and... Linings, paddings, stiffening, trimmings and facings. (a) In labeling or marking garments or articles of apparel which are wool products, the fiber content of any linings, paddings, stiffening, trimmings or...

  7. 16 CFR 300.23 - Linings, paddings, stiffening, trimmings and facings.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Linings, paddings, stiffening, trimmings and... Linings, paddings, stiffening, trimmings and facings. (a) In labeling or marking garments or articles of apparel which are wool products, the fiber content of any linings, paddings, stiffening, trimmings or...

  8. Analysis of an all-metallic resilient pad gas-lubricated thrust bearing

    NASA Technical Reports Server (NTRS)

    Anderson, W. J.

    1974-01-01

    A new type of resilient pad gas thrust bearing that does not contain any elastomers in the bearing assembly is described and analyzed. The bearing consists of sector-shaped pads mounted asymmetrically on resilient foil beams. The effects of bearing design parameters on performance are shown. Performance of a resilient pad bearing is compared with that of a pivoted pad bearing.

  9. Hemostatic action of OC-108, a novel agent for hemorrhoids, is associated with regional blood flow arrest induced by acute inflammation.

    PubMed

    Ono, Takashi; Nakagawa, Haruto; Fukunari, Atsushi; Hashimoto, Toshio; Komatsu, Hirotsugu

    2006-11-01

    Clinically, hemorrhoidal bleeding and prolapse disappeared immediately after injection of the sclerosing agent OC-108 into submucosa of hemorrhoids. The aim of this study was to elucidate the mechanism of action responsible for the immediate hemostatic effect of OC-108 using anesthetized rats. Subcutaneous injection of OC-108 in rats decreased blood flow at the injection site within 5 min. Aluminum potassium sulfate, one of the main ingredients of OC-108, reduced the skin blood flow. However, tannic acid, another main ingredient, did not. By perfusion of OC-108 on the mesenteric surface, microcirculatory blood flow was arrested without remarkable change in blood vessel diameter, accompanied by increased vascular permeability and venous hematocrit. These results indicate that OC-108 induces regional blood flow arrest with rapid onset, this effect being attributed to the action of aluminum potassium sulfate, and that hemoconcentration due to increased vascular permeability (plasma extravasation), an acute inflammatory reaction, is involved in the mechanisms of the immediate hemostatic action of OC-108.

  10. LEAVE PAD - TRAINING - CAPE

    NASA Image and Video Library

    1965-03-18

    S65-20641 (1965) --- Astronauts John W. Young (left), pilot, and Virgil I. Grissom, command pilot, for the Gemini-Titan 3 flight, are shown leaving the launch pad after simulations in the Gemini-3 spacecraft.

  11. Correlations for Saturation Efficiency of Evaporative Cooling Pads

    NASA Astrophysics Data System (ADS)

    Jain, J. K.; Hindoliya, D. A.

    2014-01-01

    This paper presents some experimental investigations to obtain correlations for saturation efficiency of evaporative cooling pads. Two commonly used materials namely aspen and khus fibers along with new materials namely coconut fibers and palash fibers were tested in a laboratory using suitably fabricated test setup. Simple mathematical correlations have been developed for calculating saturation efficiency of evaporating cooling pads which can be used to predict their performance at any desired mass flow rate. Performances of four different pad materials were also compared using developed correlations. An attempt was made to test two new materials (i.e. fibers of palash wood and coconut) to check their suitability as wetted media for evaporative cooling pads. It was found that Palash wood fibers offered highest saturation efficiency compared to that of other existing materials such as aspen and khus fibers at different mass flow rate of air.

  12. Influence of stearic acid on postprandial lipemia and hemostatic function.

    PubMed

    Sanders, Thomas A B; Berry, Sarah E E

    2005-12-01

    It has been suggested that fats rich in stearic acid may result in exaggerated postprandial lipemia and have adverse effects on hemostatic function. The effects of test meals containing different saturated and monounsaturated FA were compared in healthy subjects in a series of studies to investigate this hypothesis. Stearic acid, when present as cocoa butter, resulted in similar postprandial lipemia and factor VII activation compared with a meal containing high-oleic sunflower oil. Stearic acid when presented as shea butter or as randomized stearate-rich TAG resulted in decreased postprandial lipemia and decreased postprandial activation of factor VII. Stearic acid-rich test meals did not result in impaired fibrinolytic activity compared with either a low-fat meal or a meal high in oleate. The difference in responses between the different stearic acid-rich fats appears to be due to varying solid fat contents of the fats at 37 degrees C.

  13. Development and field performance of indy race car head impact padding.

    PubMed

    Melvin, J W; Bock, H; Anderson, K; Gideon, T

    2001-11-01

    The close-fitting cockpit of the modern Indy car single seat race car has the potential to provide a high level of head and neck impact protection in rear and side impacts. Crash investigation has shown that a wide variety of materials have been used as the padding for these cockpits and, as a result, produced varying outcomes in crashes. Additionally, these pads have not always been positioned for optimal performance. The purpose of this study was to investigate the head impact performance of a variety of energy-absorbing padding materials under impact conditions typical of Indy car rear impacts and to identify superior materials and methods of improving their performance as race car head pads. An extensive series of tests with the helmeted Hybrid III test dummy head and neck on an impact mini-sled was conducted to explore head padding concepts. Following this, a performance specification for a simplified impact test using a rigid headform that simulates the helmeted head was developed and recommendations for performance levels of head padding based on biomechanical data on helmeted head impacts were made. In 1997, during the time that the head pad research was being performed, the Indy Racing League introduced a new chassis specification for their cars. There were a number of rear- and side-impact crashes during that season that resulted in seven severe head injuries. Examples of the head padding in those cars were included in the experimental study. The results of the head pad research were used to specify new padding materials that met the new biomechanical criteria. The placement of the head pads was also changed for better location of the padding. These changes instituted in 1998 have reduced the number of head injuries in crashes similar to or more severe than those of 1997 and have resulted in only occasional moderate head injuries (concussions) in the 1998 and 1999 seasons.

  14. Pad 39B Flame Trench Brick Work

    NASA Image and Video Library

    2016-10-26

    Progress on the new brick walls of the north side of the flame trench at Launch Pad 39B is seen in a view from the top of the pad at NASA’s Kennedy Space Center in Florida. Construction workers with J.P. Donovan of Rockledge, Florida, continue to install new heat-resistant bricks on the concrete walls. The Pad B flame trench is being refurbished to support the launch of NASA’s Space Launch System rocket. The Ground Systems Development and Operations (GSDO) Program at Kennedy is helping transform the space center into a multi-user spaceport and prepare for Exploration Mission 1, deep-space missions, and the journey to Mars. For more information about GSDO, visit: http://www.nasa.gov/groundsystems.

  15. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    Praxair trucks carrying their loads of liquid oxygen, or LO2, are on their way to Launch Pad 39B at NASA's Kennedy Space Center in Florida. The trucks will offload LO2 slowly into a giant storage sphere located at the northwest corner of the pad to gradually chill it down from normal temperature to about negative 298 degrees Fahrenheit, during the first major integrated operation to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  16. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    NASA Launch Director Charlie Blackwell-Thompson, at left, arrives at Launch Pad 39B at NASA's Kennedy Space Center in Florida, to observe the first major tanking operation of liquid oxygen, or LO2, into the giant storage sphere at the northwest corner of the pad to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. During the operation, several Praxair trucks will slowly offload LO2 to gradually chill down the sphere from normal temperature to about negative 298 degrees Fahrenheit. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  17. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    Several Praxair trucks begin to depart Launch Pad 39B at NASA's Kennedy Space Center in Florida, after offloading their loads of liquid oxygen, or LO2, one at a time into the giant storage sphere located at the northwest corner of the pad. The sphere was gradually chilled down from normal temperature to about negative 298 degrees Fahrenheit, during the first major integrated operation to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  18. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    Several Praxair trucks carrying their loads of liquid oxygen, or LO2, arrive at Launch Pad 39B at NASA's Kennedy Space Center in Florida. The trucks will offload LO2 slowly into a giant storage sphere located at the northwest corner of the pad to gradually chill it down from normal temperature to about negative 298 degrees Fahrenheit, during the first major integrated operation to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  19. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    One of several Praxair trucks carrying its load of liquid oxygen, or LO2, is in route to Launch Pad 39B at NASA's Kennedy Space Center in Florida. The truck will offload LO2 slowly into a giant storage sphere located at the northwest corner of the pad to gradually chill it down from normal temperature to about negative 298 degrees Fahrenheit, during the first major integrated operation to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  20. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    Several Praxair trucks carrying their loads of liquid oxygen, or LO2, have arrived at Launch Pad 39B at NASA's Kennedy Space Center in Florida. The trucks will offload LO2 slowly into a giant storage sphere located at the northwest corner of the pad to gradually chill it down from normal temperature to about negative 298 degrees Fahrenheit, during the first major integrated operation to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  1. Exploring anatomy and physiology using iPad applications.

    PubMed

    Chakraborty, Tandra R; Cooperstein, Deborah F

    2017-11-07

    This study examined the use of iPads with anatomy applications (apps) in the laboratory sections of the largest undergraduate course at the university, Anatomy and Physiology, serving more than 300 students. The majority of these students were nursing, exercise science/physical education and biology majors. With a student survey (student opinion) and student practicum grades as metrics, this study determined whether the introduction of this novel mobile technology improved student grades and aided the students in learning the course material. The results indicated that students' grades improved with the introduction of the iPads, and 78% of the students reported that the iPads facilitated their ability to learn the course material. There was a positive association between frequency of app use and standardized mastery of the course material, as students who used the apps more frequently scored higher and indicated that they felt as though they had learned the material more comprehensively. Owning or having an iPad at home did not have a significant effect on the learning of the material. The general consensus by students was that iPad anatomy apps should be used frequently to better develop student understanding of the course material. Anat Sci Educ. © 2017 American Association of Anatomists. © 2017 American Association of Anatomists.

  2. Exploring the relationship between skin property and absorbent pad environment.

    PubMed

    Shigeta, Yoshie; Nakagami, Gojiro; Sanada, Hiromi; Oba, Miho; Fujikawa, Junko; Konya, Chizuko; Sugama, Junko

    2009-06-01

    The aim of this study is to identify the related factors of skin lesions found in the surrounding environment of absorbent pads by clinical investigation. Most older patients with incontinence use absorbent products, therefore causing many patients to have skin lesion in the absorbent pad area. To prevent these skin lesions from occurring, it is necessary to examine the absorbent pad environment of clinical patients since there are many contributing factors that complicate the pathophysiology in this area. A cross-sectional design was used. One hundred older Japanese patients with faecal and/or urinary incontinence using diapers and absorbent pads participated. Excluding blanchable erythema, the presence of skin lesions in the absorbent pad area was confirmed. Skin pH, hydration level and bacterial cultures were used to assess the skin property. Absorbent pad environment and patient demographics were also investigated. The overall prevalence of skin lesions was 36%. Forty percent of the skin lesions were contact dermatitis. Multivariate logistic regression analysis revealed that only the presence of diarrhoea independently affected contact dermatitis. There was a significant relationship between contact dermatitis and the use of absorbent pads when the patient had diarrhoea. Although the factors related to skin lesions in the absorbent pad area are complexly intertwined, this study was the first to be able to determine diarrhoea as one specific factor in clinical setting. This finding suggests that the presence of diarrhoea is significantly related with contact dermatitis. Therefore, when a patient has diarrhoea, health-care professionals should immediately implement a preventative care program which includes careful skin observation and improved skin care. It is also necessary to develop a more effective absorbent pad to protect the skin of incontinent patients who suffer from the irritating effects of liquid stool.

  3. Impact response of US Army and National Football League helmet pad systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moss, W C; King, M J

    Lawrence Livermore National Laboratory [LLNL] was tasked to compare the impact response of NFL helmet pad systems and U.S. Army pad systems compatible with an Advanced Combat Helmet [ACH] at impact velocities up to 20 ft/s. This was a one-year study funded by the U.S. Army and JIEDDO. The Army/JIEDDO point of contact is COL R. Todd Dombroski, DO, JIEDDO Surgeon. LLNL was chosen by committee to perform the research based on prior published computational studies of the mechanical response of helmets and skulls to blast. Our collaborators include the U.S. Army Aeromedical Research Laboratory [USAARL] (a DoD laboratory responsiblemore » for impact testing helmets), Team Wendy and Oregon Aero (current and former ACH pad manufacturers), Riddell and Xenith (NFL pad manufacturers), and d3o (general purpose sports pad manufacturer). The manufacturer-supplied pad systems that were studied are shown in the figure below. The first two are the Army systems, which are bilayer foam pads with both hard and soft foam and a water-resistant airtight wrapper (Team Wendy) or a water-resistant airtight coating (Oregon Aero). The next two are NFL pad systems. The Xenith system consists of a thin foam pad and a hollow air-filled cylinder that elastically buckles under load. The Riddell system is a bilayer foam pad that is encased in an inflatable airbag with relief channels to neighboring pads in the helmet. The inflatable airbag is for comfort and provides no enhancement to impact mitigation. The d3o system consists of a rate-sensitive homogeneous dense foam. LLNL performed experiments to characterize the material properties of the individual foam materials and the response of the complete pad systems, to obtain parameters needed for the simulations. LLNL also performed X-ray CT scans of an ACH helmet shell that were used to construct a geometrically accurate computational model of the helmet. Two complementary sets of simulations were performed. The first set of simulations reproduced

  4. Pad stress tests with increasing load for the diagnosis of stress urinary incontinence.

    PubMed

    Rimstad, Liv; Larsen, Elsa Skjønhaug; Schiøtz, Hjalmar A; Kulseng-Hanssen, Sigurd

    2014-09-01

    The aim of the study was to test the ability of pad stress tests with increasing load (supine, jumping on the floor, and jumping on a trampoline) to document stress incontinence in subjectively stress incontinent women. In this prospective study 147 subjectively stress and mixed incontinent women performed consecutively the three pad stress tests with a bladder volume of 300 ml. Nineteen women performed a second trampoline pad stress test to test repeatability of the test. Nine continent women performed a trampoline pad stress test in order to determine if subjectively continent women would leak during the test. Seventy-two women (49%) leaked during the supine, 136 (93%) leaked during the jumping, and 146 (99%) leaked during the trampoline pad stress test. The differences between pad stress tests were significant with P < 0.005. Correlation between the two trampoline pad stress tests was high at 0.8. None of the nine continent women leaked during the trampoline pad stress test. The supine pad stress test has low sensitivity and is therefore often falsely negative. The jumping pad stress test is a simple test to perform and is satisfactory for everyday use. Subjectively stress incontinent women who do not leak during the jumping pad stress test may perform a trampoline pad stress test to document stress incontinence. The trampoline pad stress test is also simple to perform and detected leakage in 91% of the women who did not leak during the jumping pad stress test. © 2013 Wiley Periodicals, Inc.

  5. Preventive medicine oversight of splash pads on military installations.

    PubMed

    Hardcastle, Lisa Raysby; Perry, Matthew; Browne, Ashley

    2015-01-01

    Over the past several years, an increasing number of military installations have installed splash pads that provide fun, recreational water entertainment for Soldiers and their families. The addition of splash pads brings added responsibilities for medical treatment facility preventive medicine oversight and installation facilities maintenance to ensure a safe and healthy environment. Currently, there are no consistent standards or detailed guidance for military installations to follow when installing and maintaining splash pads. The central issues associated with splash pads on military installations are water quality and risk for waterborne illnesses, responsibility for safety and health oversight, and federal energy and water sustainability mandates. This article examines the importance of implementing a standard for design and oversight to ensure the health and safety of Soldiers and their families.

  6. Computerized Spiral Analysis Using the iPad

    PubMed Central

    Sisti, Jonathan A.; Christophe, Brandon; Seville, Audrey Rakovich; Garton, Andrew L.A.; Gupta, Vivek P.; Bandin, Alexander J.; Yu, Qiping; Pullman, Seth L.

    2017-01-01

    Background Digital analysis of writing and drawing has become a valuable research and clinical tool for the study of upper limb motor dysfunction in patients with essential tremor, Parkinson’s disease, dystonia, and related disorders. We developed a validated method of computerized spiral analysis of hand-drawn Archimedean spirals that provides insight into movement dynamics beyond subjective visual assessment using a Wacom graphics tablet. While the Wacom tablet method provides robust data, more widely available mobile technology platforms exist. New Method We introduce a novel adaptation of the Wacom-based method for the collection of hand-drawn kinematic data using an Apple iPad. This iPad-based system is stand-alone, easy-to-use, can capture drawing data with either a finger or capacitive stylus, is precise, and potentially ubiquitous. Results The iPad-based system acquires position and time data that is fully compatible with our original spiral analysis program. All of the important indices including degree of severity, speed, presence of tremor, tremor amplitude, tremor frequency, variability of pressure, and tightness are calculated from the digital spiral data, which the application is able to transmit. Comparison with Existing Method While the iPad method is limited by current touch screen technology, it does collect data with acceptable congruence compared to the current Wacom-based method while providing the advantages of accessibility and ease of use. Conclusions The iPad is capable of capturing precise digital spiral data for analysis of motor dysfunction while also providing a convenient, easy-to-use modality in clinics and potentially at home. PMID:27840146

  7. Computerized spiral analysis using the iPad.

    PubMed

    Sisti, Jonathan A; Christophe, Brandon; Seville, Audrey Rakovich; Garton, Andrew L A; Gupta, Vivek P; Bandin, Alexander J; Yu, Qiping; Pullman, Seth L

    2017-01-01

    Digital analysis of writing and drawing has become a valuable research and clinical tool for the study of upper limb motor dysfunction in patients with essential tremor, Parkinson's disease, dystonia, and related disorders. We developed a validated method of computerized spiral analysis of hand-drawn Archimedean spirals that provides insight into movement dynamics beyond subjective visual assessment using a Wacom graphics tablet. While the Wacom tablet method provides robust data, more widely available mobile technology platforms exist. We introduce a novel adaptation of the Wacom-based method for the collection of hand-drawn kinematic data using an Apple iPad. This iPad-based system is stand-alone, easy-to-use, can capture drawing data with either a finger or capacitive stylus, is precise, and potentially ubiquitous. The iPad-based system acquires position and time data that is fully compatible with our original spiral analysis program. All of the important indices including degree of severity, speed, presence of tremor, tremor amplitude, tremor frequency, variability of pressure, and tightness are calculated from the digital spiral data, which the application is able to transmit. While the iPad method is limited by current touch screen technology, it does collect data with acceptable congruence compared to the current Wacom-based method while providing the advantages of accessibility and ease of use. The iPad is capable of capturing precise digital spiral data for analysis of motor dysfunction while also providing a convenient, easy-to-use modality in clinics and potentially at home. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Demonstrating Optical Activity Using an iPad

    ERIC Educational Resources Information Center

    Schwartz, Pauline M.; Lepore, Dante M.; Morneau, Brandy N.; Barratt, Carl

    2011-01-01

    Optical activity using an iPad as a source of polarized light is demonstrated. A sample crystal or solution can be placed on the iPad running a white screen app. The sample is viewed through a polarized filter that can be rotated. This setup can be used in the laboratory or with a document camera to easily project in a large lecture hall.…

  9. Visible light active photocatalyst from recycled disposable heating pads

    NASA Astrophysics Data System (ADS)

    Lee, Meng-Chien; Wang, Chun-Yu; Chen, Che-Chin; Wang, Chih-Ming; Hsiao, Ta-Chih; Tsai, Din Ping

    2016-01-01

    Alpha-Fe2O3 (α-Fe2O3) is cheap and abundant and has potential to be a highly efficient photocatalyst for water splitting. According to the report, there are a huge amount of disposable heating pads being created every year, and the pads are used one time then thrown away. We found that the main product of used heating pads is α-Fe2O3. Here, we collect and purify the α-Fe2O3 powder in the used heating pads using low power consumption processes. It is shown that the recycled heating pads can be used as a cost-effective photocatalyst for H2 energy and for decomposition of organic pollutants as well. Additionally, the plasmonic enhanced photocatalysis reaction of α-Fe2O3 is also investigated. It is found that H2 evolution rate can be enhanced 15% using α-Fe2O3 nanoparticles coated with a thin Au layer. The degradation of methylene blue can also enhance 12% compared to photocatalyst α-Fe2O3 nanoparticles coated without Au layer.

  10. Analysis of the gas-lubricated flat-sector-pad thrust bearing

    NASA Technical Reports Server (NTRS)

    Etsion, I.

    1976-01-01

    A flat sector-shaped pad geometry for a gas-lubricated thrust bearing is analyzed considering both the pitch and roll of the pad. It is shown that maximum load capacity is achieved when the pad is tilted so as to create uniform minimum film thickness along the pad trailing edge. Performance characteristics for various geometries and operating conditions of gas thrust bearings are presented in the form of design curves, and a comparison is made with the rectangular slider approximation. It is found that this approximation is unsafe for practical design, since it always overestimates load capacity.

  11. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    NASA Launch Director Charlie Blackwell-Thompson, center, talks to engineers at Launch Pad 39B at the agency's Kennedy Space Center in Florida. Blackwell-Thompson will observe the first major tanking operation of liquid oxygen, or LO2, into the giant storage sphere at the northwest corner of the pad to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. During the operation, several Praxair trucks will slowly offload LO2 to gradually chill down the sphere from normal temperature to about negative 298 degrees Fahrenheit. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  12. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    NASA Launch Director Charlie Blackwell-Thompson, at right, greets engineers and technicians at Launch Pad 39B at the agency's Kennedy Space Center in Florida. Blackwell-Thompson will observe the first major tanking operation of liquid oxygen, or LO2, into the giant storage sphere at the northwest corner of the pad to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. During the operation, several Praxair trucks will slowly offload LO2 to gradually chill down the sphere from normal temperature to about negative 298 degrees Fahrenheit. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  13. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    Several Praxair trucks carrying their loads of liquid oxygen, or LO2, have arrived at Launch Pad 39B at NASA's Kennedy Space Center in Florida. A mist is visible as LO2 is offloaded from one of the trucks into the giant storage sphere located at the northwest corner of the pad has begun. The sphere will gradually be chilled down from normal temperature to about negative 298 degrees Fahrenheit, during the first major integrated operation to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  14. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    Several Praxair trucks carrying their loads of liquid oxygen, or LO2, have arrived at Launch Pad 39B at NASA's Kennedy Space Center in Florida. The trucks will begin to offload the LO2 one at a time into the giant storage sphere located at the northwest corner of the pad. The sphere will gradually be chilled down from normal temperature to about negative 298 degrees Fahrenheit, during the first major integrated operation to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  15. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    Engineers watch as several Praxair trucks carrying their loads of liquid oxygen, or LO2, arrive at Launch Pad 39B at NASA's Kennedy Space Center in Florida. The trucks will offload the LO2 one at a time into the giant storage sphere located at the northwest corner of the pad. The sphere will gradually be chilled down from normal temperature to about negative 298 degrees Fahrenheit, during the first major integrated operation to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  16. Perceptions and use of iPad technology by pharmacy practice faculty members.

    PubMed

    DiVall, Margarita V; Zgarrick, David P

    2014-04-17

    To explore the potential of tablet technology to address the specific workload challenges of pharmacy practice faculty members and to evaluate tablet usage after a department-wide iPad initiative. After conducting a needs assessment to determine pharmacy faculty attitudes towards tablet technology and to identify potential usage scenarios, all faculty members in a department of pharmacy practice received an iPad. After iPad distribution, training sessions and virtual tutorials were provided. An anonymous survey was administered to evaluate the pilot. The needs assessment survey revealed positive attitudes towards iPad technology, identified use scenarios, and led to a department-wide iPad pilot program. Most faculty members used iPads for connectivity with students (86%), paper/project annotation (68%), assessment (57%), and demonstration of tools used in practice (36%). For teaching, 61% of faculty members used iPads in seminars/laboratories, 57% used iPads in the experiential setting, and 43% used iPads in the classroom. Use of iPads for patient-care activities varied and depended on site support for mobile technology. The 23 faculty members with external practice sites used iPads to a greater extent and had more positive attitudes towards this technology compared with campus-based faculty members. Integration of tablet technology into the pharmacy education setting resulted in faculty-reported increased productivity and decreased paper waste. It also allowed faculty members to experiment with new teaching strategies in the classroom and experiential setting. Administrators at institutions exploring the use of tablet technology should allocate resources based on faculty needs and usage patterns.

  17. Launch Pad in a Box

    NASA Technical Reports Server (NTRS)

    Mantovani, J. G.; Tamasy, G. J.; Mueller, R. P.; Townsend, I. I.; Sampson, J. W.; Lane, M. A.

    2016-01-01

    NASA Kennedy Space Center (KSC) is developing a new deployable launch system capability to support a small class of launch vehicles for NASA and commercial space companies to test and launch their vehicles. The deployable launch pad concept was first demonstrated on a smaller scale at KSC in 2012 in support of NASA Johnson Space Center's Morpheus Lander Project. The main objective of the Morpheus Project was to test a prototype planetary lander as a vertical takeoff and landing test-bed for advanced spacecraft technologies using a hazard field that KSC had constructed at the Shuttle Landing Facility (SLF). A steel pad for launch or landing was constructed using a modular design that allowed it to be reconfigurable and expandable. A steel flame trench was designed as an optional module that could be easily inserted in place of any modular steel plate component. The concept of a transportable modular launch and landing pad may also be applicable to planetary surfaces where the effects of rocket exhaust plume on surface regolith is problematic for hardware on the surface that may either be damaged by direct impact of high speed dust particles, or impaired by the accumulation of dust (e.g., solar array panels and thermal radiators). During the Morpheus free flight campaign in 2013-14, KSC performed two studies related to rocket plume effects. One study compared four different thermal ablatives that were applied to the interior of a steel flame trench that KSC had designed and built. The second study monitored the erosion of a concrete landing pad following each landing of the Morpheus vehicle on the same pad located in the hazard field. All surfaces of a portable flame trench that could be directly exposed to hot gas during launch of the Morpheus vehicle were coated with four types of ablatives. All ablative products had been tested by NASA KSC and/or the manufacturer. The ablative thicknesses were measured periodically following the twelve Morpheus free flight tests

  18. Launch Pad in a Box

    NASA Technical Reports Server (NTRS)

    Mantovani, James; Tamasy, Gabor; Mueller, Rob; Townsend, Van; Sampson, Jeff; Lane, Mike

    2016-01-01

    NASA Kennedy Space Center (KSC) is developing a new deployable launch system capability to support a small class of launch vehicles for NASA and commercial space companies to test and launch their vehicles. The deployable launch pad concept was first demonstrated on a smaller scale at KSC in 2012 in support of NASA Johnson Space Center's Morpheus Lander Project. The main objective of the Morpheus Project was to test a prototype planetary lander as a vertical takeoff and landing test-bed for advanced spacecraft technologies using a hazard field that KSC had constructed at the Shuttle Landing Facility (SLF). A steel pad for launch or landing was constructed using a modular design that allowed it to be reconfigurable and expandable. A steel flame trench was designed as an optional module that could be easily inserted in place of any modular steel plate component. The concept of a transportable modular launch and landing pad may also be applicable to planetary surfaces where the effects of rocket exhaust plume on surface regolith is problematic for hardware on the surface that may either be damaged by direct impact of high speed dust particles, or impaired by the accumulation of dust (e.g., solar array panels and thermal radiators). During the Morpheus free flight campaign in 2013-14, KSC performed two studies related to rocket plume effects. One study compared four different thermal ablatives that were applied to the interior of a steel flame trench that KSC had designed and built. The second study monitored the erosion of a concrete landing pad following each landing of the Morpheus vehicle on the same pad located in the hazard field. All surfaces of a portable flame trench that could be directly exposed to hot gas during launch of the Morpheus vehicle were coated with four types of ablatives. All ablative products had been tested by NASA KSC and/or the manufacturer. The ablative thicknesses were measured periodically following the twelve Morpheus free flight tests

  19. Grippers Based on Opposing Van Der Waals Adhesive Pads

    NASA Technical Reports Server (NTRS)

    Parness, Aaron (Inventor); Kennedy, Brett A. (Inventor); Heverly, Matthew C (Inventor); Cutkosky, Mark R. (Inventor); Hawkes, Elliot Wright (Inventor)

    2016-01-01

    Novel gripping structures based on van der Waals adhesive forces are disclosed. Pads covered with fibers can be activated in pairs by opposite forces, thereby enabling control of the adhesive force in an ON or OFF state. Pads can be used in groups, each comprising a group of opposite pads. The adhesive structures enable anchoring forces that can resist adverse forces from different directions. The adhesive structures can be used to enable the operation of robots on surfaces of space vehicles.

  20. The PEN&PAD data entry system: from prototype to practical system.

    PubMed Central

    Kirby, J.; Rector, A. L.

    1996-01-01

    This paper describes some of the issues addressed in the transition of the PEN&PAD from prototype clinical workstation to practical data entry system for use by general practitioners in the UK. Background and motivation of the PEN&PAD and GALEN projects are presented before the operation of the PEN&PAD user interface is described. A number of issues which have arisen in the development of the PEN&PAD Data Entry System are discussed. PMID:8947757

  1. Blood Hemostatic Changes During an Ultraendurance Road Cycling Event in a Hot Environment.

    PubMed

    Kupchak, Brian R; Kazman, Josh B; Vingren, Jakob L; Levitt, Danielle E; Lee, Elaine C; Williamson, Keith H; Armstrong, Lawrence E; Deuster, Patricia A

    2017-09-01

    This study aims to examine blood hemostatic responses to completing a 164-km road cycling event in a hot environment. Thirty-seven subjects (28 men and 9 women; 51.8±9.5 [mean±SD] y) completed the ride in 6.6±1.1 hours. Anthropometrics (height, body mass [taken also during morning of the ride], percent body fat [%]) were collected the day before the ride. Blood samples were collected on the morning of the ride (PRE) and immediately after (IP) the subject completed the ride. Concentrations of platelet, platelet activation, coagulation, and fibrinolytic markers (platelet factor 4, β-thromboglobulin, von Willebrand factor antigen, thrombin-antithrombin complex, thrombomodulin, and D-Dimer) were measured. Associations between changes from PRE- to IP-ride were examined as a function of event completion time and subject characteristics (demographics and anthropometrics). All blood hemostatic markers increased significantly (P < .001) from PRE to IP. After controlling for PRE values, finishing time was negatively correlated with platelet factor 4 (r = 0.40; P = .017), while percent body fat (%BF) was negatively correlated with thrombin-antithrombin complex (r = -0.35; P = .038) and to thrombomodulin (r = -0.36; P = .036). In addition, male subjects had greater concentrations of thrombin-antithrombin complex (d = 0.63; P < .05) and natural logarithm thrombomodulin (d = 6.42; P < .05) than female subjects. Completing the 164-km road cycling event in hot conditions resulted in increased concentrations of platelet, platelet activation, coagulation, and fibrinolytic markers in both men and women. Although platelet activation and coagulation occurred, the fibrinolytic system markers also increased, which appears to balance blood hemostasis and may prevent clot formation during exercise in a hot environment. Published by Elsevier Inc.

  2. Environmental effects and characterization of the Egyptian radioactive well logging calibration pad facility.

    PubMed

    Al Alfy, Ibrahim Mohammad

    2013-12-01

    A set of ten radioactive well-logging calibration pads were constructed in one of the premises of the Nuclear Materials Authority (NMA), Egypt, at 6th October city. These pads were built for calibrating geophysical well-logging instruments. This calibration facility was conducted through technical assistance and practical support of the International Atomic Energy Agency (IAEA) and (ARCN). There are five uranium pads with three different uranium concentrations and borehole diameters. The other five calibration pads include one from each of the following: blank, potassium, thorium, multi layers and mixed. More than 22 t of various selected Egyptian raw materials were gathered for pad construction from different locations in Egypt. Pad's site and the surrounding area were spectrometrically surveyed before excavation for the construction process of pad-basin floor. They yielded negligible radiation values which are very near to the detected general background. After pad's construction, spectrometric measurements were carried out again in the same locations when the exposed bore holes of the pads were closed. No radioactivity leakage was noticed from the pads. Meanwhile, dose rate values were found to range from 0.12 to 1.26 mS/y. They were measured during the opening of bore holes of the pads. These values depend mainly upon the type and concentration of the pads as well as their borehole diameters. The results of radiospectrometric survey illustrate that the specification of top layers of the pads were constructed according to international standards. © 2013 Elsevier Ltd. All rights reserved.

  3. Heavy Metal Pad Shielding during Fluoroscopic Interventions

    PubMed Central

    Dromi, Sergio; Wood, Bradford J.; Oberoi, Jay; Neeman, Ziv

    2008-01-01

    Significant direct and scatter radiation doses to patient and physician may result from routine interventional radiology practice. A lead-free disposable tungsten antimony shielding pad was tested in phantom patients during simulated diagnostic angiography procedures. Although the exact risk of low doses of ionizing radiation is unknown, dramatic dose reductions can be seen with routine use of this simple, sterile pad made from lightweighttungsten antimony material. PMID:16868175

  4. The effects of a low-dose monophasic preparation of levonorgestrel and ethinyl estradiol on coagulation and other hemostatic factors.

    PubMed

    Archer, D F; Mammen, E F; Grubb, G S

    1999-11-01

    This study was undertaken to evaluate the effects on hemostatic factors of a low-dose preparation of levonorgestrel and ethinyl estradiol in a 12-cycle study. Thirty healthy women began taking 100 microg levonorgestrel and 20 microg ethinyl estradiol on the first day of the menstrual cycle, continued to take the preparation for the next 21 days, and then took placebo for 7 days. Mean changes in prothrombin time, partial thromboplastin time, and levels of factors VII and X, antithrombin, plasminogen, fibrinogen, protein S, thrombin-antithrombin complexes, and D-dimer were analyzed at baseline and at cycles 3, 6, and 12 with paired Student t tests. Factor X, plasminogen antigen and activity, and D-dimer levels were significantly increased (P hemostatic factors in healthy women of a monophasic preparation of 100 microg levonorgestrel and 20 microg ethinyl estradiol were similar to those of other low-dose oral contraceptives.

  5. Investigation of elastomeric bearing pad failures in Louisiana bridges.

    DOT National Transportation Integrated Search

    1999-09-01

    Elastomeric bearing pads provide a medium to transfer girder loads to the supporting substructure. Low cost and low maintenance, in comparison with mechanical-type bearings, make elastomeric bearing pads attractive to use. However, some problems have...

  6. Identifying novel genetic determinants of hemostatic balance.

    PubMed

    Ginsburg, D

    2005-08-01

    Incomplete penetrance and variable expressivity confound the diagnosis and therapy of most inherited thrombotic and hemorrhagic disorders. For many of these diseases, some or most of this variability is determined by genetic modifiers distinct from the primary disease gene itself. Clues toward identifying such modifier genes may come from studying rare Mendelian disorders of hemostasis. Examples include identification of the cause of combined factor V and VIII deficiency as mutations in the ER Golgi intermediate compartment proteins LMAN1 and MCFD2. These proteins form a cargo receptor that facilitates the transport of factors V and VIII, and presumably other proteins, from the ER to the Golgi. A similar positional cloning approach identified ADAMTS-13 as the gene responsible for familial TTP. Along with the work of many other groups, these findings identified VWF proteolysis by ADAMTS-13 as a key regulatory pathway for hemostasis. Recent advances in mouse genetics also provide powerful tools for the identification of novel genes contributing to hemostatic balance. Genetic studies of inbred mouse lines with unusually high and unusually low plasma VWF levels identified polymorphic variation in the expression of a glycosyltransferase gene, Galgt2, as an important determinant of plasma VWF levels in the mouse. Ongoing studies in mice genetically engineered to carry the factor V Leiden mutation may similarly identify novel genes contributing to thrombosis risk in humans.

  7. Validation of the Australian Propensity for Angry Driving Scale (Aus-PADS).

    PubMed

    Leal, Nerida L; Pachana, Nancy A

    2009-09-01

    The present study used a university sample to assess the test-retest reliability and validity of the Australian Propensity for Angry Driving Scale (Aus-PADS). The scale has stability over time, and convergent validity was established, as Aus-PADS scores correlated significantly with established anger and impulsivity measures. Discriminant validity was also established, as Aus-PADS scores did not correlate with Venturesomeness scores. The Aus-PADS has demonstrated criterion validity, as scores were correlated with behavioural measures, such as yelling at other drivers, gesturing at other drivers, and feeling angry but not doing anything. Aus-PADS scores reliably predicted the frequency of these behaviours over and above other study variables. No significant relationship between aggressive driving and crash involvement was observed. It was concluded that the Aus-PADS is a reliable and valid tool appropriate for use in Australian research, and that the potential relationship between aggressive driving and crash involvement warrants further investigation with a more representative (and diverse) driver sample.

  8. Improvement of luster consistency between the p-Pad and the n-Pad of GaN-based light-emitting diodes via the under-etching process

    NASA Astrophysics Data System (ADS)

    Zheng, Chenju; Lv, Jiajiang; Zhou, Shengjun; Liu, Sheng

    2017-04-01

    For improvement of the light extraction efficiency of GaN-based lateral light-emitting diodes (LEDs), a p-GaN surface was textured through a low-temperature (850 °C) p-GaN growth process. However, the p-GaN texturing process caused luster inconsistency between the n-pad and the p-pad due to the roughness difference between the indium-tin oxide (ITO) and the n-GaN beneath the pads, which decreased the image recognition rate and accuracy during the wire bonding process for LED packaging. Therefore, an under-etching process was proposed to improve the luster consistency between the p-pad and the n-pad of GaN-based LEDs with a naturally textured p-GaN surface. The under-etching process decreased the roughness of the exposed n-GaN surface from 109 nm to 73.1 nm, which was similar to the roughness (74.8 nm) of the ITO surface. Optical microscopy showed that LEDs with a naturally textured p-GaN surface exhibited excellent luster consistency between the n-pad and the p-pad after the proposed under-etching process had been applied. Further analysis indicated that the LEDs with a naturally textured p-GaN surface showed no degradation of optical or the electrical performance after the proposed under-etching process had been applied. At a 20-mA injection current, the light output power of a LED with naturally a textured p-GaN surface was 8.7% higher than that of a LED with a smooth p-GaN surface.

  9. Effect of comfort pads and incubator design on neonatal radiography.

    PubMed

    Jiang, Xia; Baad, Michael; Reiser, Ingrid; Feinstein, Kate A; Lu, Zhengfeng

    2016-01-01

    There has been increasing interest in patient dose reduction in neonatal intensive care units. Removing comfort pads for radiography has been identified as a potential means to decrease patient dose. To assess the effect of comfort pads and support trays on detector entrance exposure (DEE) and image quality for neonatal radiography, and its implication for patient dose. Comfort pads and support trays from three incubator and warmer systems were examined. The attenuation of the primary beam by these structures was measured using a narrow beam geometry. Their effect on DEE and image quality was then assessed using typical neonatal chest radiography techniques with three configurations: 1) both the comfort pad and support included in the beam, 2) only the support tray included and 3) both the comfort pad and support tray removed. Comfort pads and support trays were found to attenuate the primary beam by 6-15%. Eliminating these structures from the X-ray beam's path was found to increase the detector entrance exposure by 28-36% and increase contrast-to-noise ratio by more than 21%, suggesting room for patient dose reduction when the same image quality is maintained. Comfort pads and tray support devices can have a considerable effect on DEE and image quality, with large variations among different incubator designs. Positioning the image detector directly underneath neonatal patients for radiography is a potential means for patient dose reduction. However, such benefit should be weighed against the risks of moving the patient.

  10. Implementing iPads in the Inclusive Classroom Setting

    ERIC Educational Resources Information Center

    Maich, Kimberly; Hall, Carmen

    2016-01-01

    This column provides practical suggestions to help guide teachers in utilizing classroom sets of iPads. Following a brief introduction to tablet technology in inclusive classrooms and the origin of these recommendations from a case study focus group, important elements of setting up classroom iPad use, from finding funding to teaching apps, are…

  11. Alteration of Hemostatic Parameters in Patients with Different Levels of Subclinical Hypothyroidism and the Effect of L-thyroxine Treatment.

    PubMed

    Gao, Fang; Wang, Guangya; Xu, Jinxiu

    2017-01-01

    Subclinical hypothyroidism (SH) is associated with hypercoagulability and hypofibrinolysis. The objective of this study was to assess the effect of L-thyroxine (L-T4) treatment and to evaluate changes in the hemostatic abnormalities of patients with varying severities of SH. We measured tissue plasminogen activator (t-PA), plasminogen activator inhibitor-1 (PAI-1), D-dimer (DDI), fibrinogen (FIB), platelet counts (PLT), mean platelet volume (MPV), platelet distribution width (PDW), activated partial thromboplastin time (APTT), and prothrombin time (PT) in 149 female subjects. The prospective study included 54 patients in the control group, 53 patients with 4.2 μIU/mLhemostatic parameters in the mild SH patients were not different compared with those of the control group. After 6 months of L-T4 treatment, a significant decrease in FIB, PAI-1 and t-PA levels and an increase in APTT and DDI were observed in the severe SH group. In conclusion, SH patients displayed a distinct pattern of alteration of hemostatic parameters that was dependent on the severity of the disease. Patients with TSH levels ≥10 μIU/mL displayed hypercoagulability, which was reversed by 6 months of L-T4 treatment. © 2017 by the Association of Clinical Scientists, Inc.

  12. Parametric studies on floating pad journal bearing for high speed cryogenic turboexpanders

    NASA Astrophysics Data System (ADS)

    Jain, A.; Jadhav, M. M.; Karimulla, S.; Chakravarty, A.

    2017-12-01

    Most modern medium and large capacity helium liquefaction/refrigeration plants employ high speed cryogenic turboexpanders in their refrigeration/liquefaction cycles as active cooling devices. The operating speed of these turboexpanders is in the range of 3000-5000 Hz and hence specialized types of bearings are required. Floating pad journal bearing, which is a special type of tilting pad journal bearing, where mechanical pivots are absent and pads are fully suspended in gas, can be a good solution for stable operation of these high speed compact rotors. The pads are separated from shaft as well as from housing by fluid film between them, and both these sides of pad are interconnected by a network of feed holes. The work presented in this article aims to characterize floating pad journal bearings through parametric studies. The steady state performance characteristics of the bearing are represented by load capacity, stiffness coefficients and heat generation rate of the bearing. The geometrical parameters such as bearing clearances, preload of pads, etc. are varied and performance characteristics of the floating pad journal bearing are studied and presented. The dependence of stiffness coefficients on rotational speed of shaft is also analyzed.

  13. On pads and filters: Processing strong-motion data

    USGS Publications Warehouse

    Boore, D.M.

    2005-01-01

    Processing of strong-motion data in many cases can be as straightforward as filtering the acceleration time series and integrating to obtain velocity and displacement. To avoid the introduction of spurious low-frequency noise in quantities derived from the filtered accelerations, however, care must be taken to append zero pads of adequate length to the beginning and end of the segment of recorded data. These padded sections of the filtered acceleration need to be retained when deriving velocities, displacements, Fourier spectra, and response spectra. In addition, these padded and filtered sections should also be included in the time series used in the dynamic analysis of structures and soils to ensure compatibility with the filtered accelerations.

  14. Renal, gastrointestinal, and hemostatic effects of oral administration of meloxicam to Hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    Dijkstra, Bas; Guzman, David Sanchez-Migallon; Gustavsen, Kate; Owens, Sean D; Hass, Carlyle; Kass, Philip H; Paul-Murphy, Joanne R

    2015-04-01

    To investigate renal, gastrointestinal, and hemostatic effects associated with oral administration of multiple doses of meloxicam to healthy Hispaniolan Amazon parrots (Amazona ventralis). 12 Hispaniolan Amazon parrots. Birds were assigned to receive meloxicam oral suspension (1.6 mg/kg, PO, q 12 h) and 2.5 mL of tap water inserted into the crop by use of a gavage tube (n = 8) or the equivalent volume of tap water only (control group; 4) for 15 days. Urine and feces were collected 2 hours after treatment administration each day. Feces were evaluated for occult blood. Results of a CBC and serum biochemical analysis and measured N-acetyl-β-d-glucosaminidase (NAG) activity and whole blood clotting time were evaluated before, during, and after completion of treatments. Results of urinalysis and measured urine NAG activity were also evaluated. Birds treated with meloxicam had a significant increase in number of WBCs and decrease in PCV from before to after treatment. The PCV also decreased significantly, compared with results for the control group; however, WBC count and PCV for all birds remained within reference ranges throughout the study. One parrot treated with meloxicam had a single high value for urine NAG activity. Meloxicam administered orally at the dosage used in this study caused no apparent negative changes in several renal, gastrointestinal, or hemostatic variables in healthy Hispaniolan Amazon parrots. Additional studies to evaluate adverse effects of NSAIDs in birds will be needed.

  15. Opportunity Looks Back After Hop to a New Pad

    NASA Image and Video Library

    2010-05-19

    NASA rover Opportunity captured this image of the tracks the rover left on a drive from one energy-favorable position on the northern end of a sand ripple to another. The rover team calls this hopping from lily pad to lily pad.

  16. iPads in Inclusive Classrooms: Ecologies of Learning

    ERIC Educational Resources Information Center

    Meyer, Bente

    2013-01-01

    This paper builds on data from a project where iPads were used in a lower secondary school in Denmark to support school development and inclusive learning environments. The paper explores how iPads enter into and work as part of an ecology of learning in five classes in lower secondary school. The paper argues that we should disengage approaches…

  17. Exploring Leadership in Schools-Based iPad Initiatives: A Case Study

    ERIC Educational Resources Information Center

    Harrold, Richard

    2017-01-01

    The world's first school-based one-to-one iPad initiative was implemented in a British school in 2010. Every year since, more iPad initiatives have been implemented in British schools, with school leaders citing various reasons for introducing them. However, results of iPad initiatives have not always matched expectations. British schools are also…

  18. PAD-US: National Inventory of Protected Areas

    USGS Publications Warehouse

    Gergely, Kevin J.; McKerrow, Alexa

    2013-11-12

    The Gap Analysis Program produces data and tools that help meet critical national challenges such as biodiversity conservation, renewable energy development, climate change adaptation, and infrastructure investment. The Protected Areas Database of the United States (PAD-US) is the official inventory of protected open space in the United States. With over 715 million acres in thousands of holdings, the spatial data in PAD-US include public lands held in trust by national, State, and some local governments, and by some nonprofit conservation organizations.

  19. Simulating pad-electrodes with high-definition arrays in transcranial electric stimulation

    NASA Astrophysics Data System (ADS)

    Kempe, René; Huang, Yu; Parra, Lucas C.

    2014-04-01

    Objective. Research studies on transcranial electric stimulation, including direct current, often use a computational model to provide guidance on the placing of sponge-electrode pads. However, the expertise and computational resources needed for finite element modeling (FEM) make modeling impractical in a clinical setting. Our objective is to make the exploration of different electrode configurations accessible to practitioners. We provide an efficient tool to estimate current distributions for arbitrary pad configurations while obviating the need for complex simulation software. Approach. To efficiently estimate current distributions for arbitrary pad configurations we propose to simulate pads with an array of high-definition (HD) electrodes and use an efficient linear superposition to then quickly evaluate different electrode configurations. Main results. Numerical results on ten different pad configurations on a normal individual show that electric field intensity simulated with the sampled array deviates from the solutions with pads by only 5% and the locations of peak magnitude fields have a 94% overlap when using a dense array of 336 electrodes. Significance. Computationally intensive FEM modeling of the HD array needs to be performed only once, perhaps on a set of standard heads that can be made available to multiple users. The present results confirm that by using these models one can now quickly and accurately explore and select pad-electrode montages to match a particular clinical need.

  20. Analysis of novel cardiovascular biomarkers in patients with peripheral artery disease (PAD).

    PubMed

    Jirak, Peter; Mirna, Moritz; Wernly, Bernhard; Paar, Vera; Thieme, Marcus; Betge, Stefan; Franz, Marcus; Hoppe, Uta; Lauten, Alexander; Kammler, Jürgen; Schulze, Paul C; Lichtenauer, Michael; Kretzschmar, Daniel

    2018-04-12

    Peripheral artery disease (PAD) is a common form of manifestation of atherosclerosis. PAD has a considerable impact on morbidity, hospitalisation rates and health- care costs. Biomarkers have been introduced in many cardiovascular disease entities over the last years. However, an analysis on the correlation of biomarker levels and PAD is still lacking. A total of 106 patients were enrolled in this current study, 51 that were diagnosed with PAD and 55 with excluded coronary and peripheral artery disease as controls. During outpatient visits, plasma samples of all patients were obtained and analyzed for sST2 (hemodynamics and inflammation), Galectin-3 (fibrosis and remodeling), GDF-15 (remodeling and inflammation), suPAR (inflammation), and Fetuin-A (vascular calcification) by use of ELISA after informed consent. Compared with controls, patients with PAD showed significantly higher levels of sST2 (5248 vs. 7503 pg/ml, p<0.001), suPAR (2267 vs. 2414 pg/ml, p=0.02), Galectin-3 (2795 vs. 4494 pg/ml, p<0.001), and GDF-15 (549 vs. 767 pg/ml, p<0.001). Fetuin-A showed a trend towards lower levels in patients with PAD (117 vs. 100 ng/ml, p=0.119). Circulating levels of sST2, suPAR, Galectin-3, and GDF-15 were significantly elevated in PAD patients. In contrast, Fetuin-A levels showed a decrease in PAD patients indicating increased vascular calcification. Thus, by incorporating different pathophysiological processes present in PAD, tested novel biomarkers facilitate a more precise diagnosis as well as a more accurate evaluation of disease severity and progression.

  1. A novel hemostatic powder for upper gastrointestinal bleeding: a multicenter study (the "GRAPHE" registry).

    PubMed

    Haddara, Sami; Jacques, Jeremie; Lecleire, Stéphane; Branche, Julien; Leblanc, Sarah; Le Baleur, Yann; Privat, Jocelyn; Heyries, Laurent; Bichard, Philippe; Granval, Philippe; Chaput, Ulriikka; Koch, Stephane; Levy, Jonathan; Godart, Bruno; Charachon, Antoine; Bourgaux, Jean-François; Metivier-Cesbron, Elodie; Chabrun, Edouard; Quentin, Vincent; Perrot, Bastien; Vanbiervliet, Geoffroy; Coron, Emmanuel

    2016-12-01

    Background and study aims: The hemostatic powder TC-325 (Hemospray; Cook Medical, Winston-Salem, North Carolina, USA) has shown promising results in the treatment of upper gastrointestinal bleeding (UGIB) in expert centers in pilot studies. The aim of this study was to evaluate the feasibility and efficacy of TC-325 in a large prospective registry of use in routine practice. Patients and methods: The data of all patients treated with TC-325 were prospectively collected through a national registry. Outcomes were the immediate feasibility and efficacy of TC-325 application, as well as the rates of rebleeding at Day 8 and Day 30. Multivariate analysis was performed to determine predictive factors of rebleeding. Results: A total of 202 patients were enrolled and 64 endoscopists participated from 20 centers. TC-325 was used as salvage therapy in 108 patients (53.5 %). The etiology of bleeding was an ulcer in 75 patients (37.1 %), tumor in 61 (30.2 %), postendoscopic therapy in 35 (17.3 %), or other in 31 (15.3 %). Application of the hemostatic powder was found to be very easy or easy in 31.7 % and 55.4 %, respectively. The immediate efficacy rate was 96.5 %. Recurrence of UGIB was noted at Day 8 and Day 30 in 26.7 % and 33.5 %, respectively. Predictive factors of recurrence at Day 8 were melena at initial presentation and use of TC-325 as salvage therapy. Conclusion: These multicenter data confirmed the high rate of immediate hemostasis, excellent feasibility, and good safety profile of TC-325, which could become the treatment of choice in bleeding tumors or postendoscopic bleeding but not in bleeding ulcers where randomized studies are needed. ClinicalTrials.gov (NCT02595853). © Georg Thieme Verlag KG Stuttgart · New York.

  2. Novel keratin (KeraStat™) and polyurethane (Nanosan(R)-Sorb) biomaterials are hemostatic in a porcine lethal extremity hemorrhage model.

    PubMed

    Burnett, Luke R; Richter, Jillian G; Rahmany, Maria B; Soler, Roberto; Steen, Julie A; Orlando, Giuseppe; Abouswareb, Tamer; Van Dyke, Mark E

    2014-02-01

    Traumatic injury is the leading cause of death in people aged 44 or less in the US. It is also estimated that 82% of deaths from battlefield hemorrhage may be survivable with better treatment options. In this study, two biomaterial hemostats having disparate mechanisms were evaluated in a large animal lethal hemorrhage model and compared to a commercial product and standard cotton gauze. We hypothesized that the biomaterial with a biologically active mechanism, as opposed to a mechanical mechanism, would be the most effective in this model. Using a published study protocol, the femoral artery in swine was punctured and treated. KeraStat™ (KeraNetics) and Nanosan®-Sorb (SNS Nano) hemostats were compared to a commercial chitosan dressing (second generation Hemcon®) and cotton gauze. Both KeraStat and Nanosan increased survival, significantly increased mean arterial pressure (MAP), and significantly decreased shock index compared to both controls. The Hemcon dressing was no different than gauze. Platelet adhesion assays suggested that the KeraStat mechanism of action involves β1 integrin mediated platelet adhesion while Nanosan-Sorb operates similar to one reported mechanism for Hemcon, absorbing fluid and concentrating clotting components. The Nanosan also swelled considerably and created pressure within the wound site even after direct pressure was removed.

  3. Hemostatic agents and instruments in laparoscopic renal surgery.

    PubMed

    Msezane, Lambda P; Katz, Mark H; Gofrit, Ofer N; Shalhav, Arieh L; Zorn, Kevin C

    2008-03-01

    Control of bleeding is one of the most technically challenging steps in laparoscopic renal surgery, especially partial nephrectomy. Although there is no consensus on how best to approach hemostasis, the options continue to expand. The original method of sutured renorrhaphy is, perhaps, the most effective; however, great skill is needed to avoid prolonged warm ischemia. Tissue sealants and adhesives serve as a barrier to leakage and as a hemostat. The four classes are fibrin sealants, collagen-based adhesives, hydrogel, and glutaraldehyde-based adhesive. Additionally, oxidized cellulose can be applied to the surface of kidney or used as a bolster. Fibrin sealants are self-activating and work best on a dry field. The gelatin matrix agent consists of human-derived thrombin with a calcium chloride solution and bovine-derived gelatin matrix. The fibrinogen required to form a clot comes from autologous blood. Another product is polyethylene glycol-based hydrogel, which acts as a mechanical sealant. The tissue glue consists of bovine serum albumin and glutaraldehyde, which cross-link to each other, as well as to other tissue proteins. Excessive use or spillage around the renal pelvis and ureter may compromise urinary flow. The methylcellulose products, consisting of oxidized cellulose sheets, usually are positioned within a sutured bolster and act in part by providing direct pressure. A number of energy-based technologies also have been utilized. Monopolar cautery consists of a high-frequency electrical current delivered from a single electrode. Care must be taken to avoid injurious current transfer to surrounding structures. With bipolar cautery, hemostasis occurs only between the electrodes. In the argonbeam coagulator, argon, an inert non-flammable gas that clears from the body rapidly, is coupled with an electrosurgical generator. The gas creates a more even distribution of the energy and better sealing of the tissues. There have been a few reports of serious

  4. Hemostatic potential of natural/synthetic polymer based hydrogels crosslinked by gamma radiation

    NASA Astrophysics Data System (ADS)

    Barba, Bin Jeremiah D.; Tranquilan-Aranilla, Charito; Abad, Lucille V.

    2016-01-01

    Various raw materials and hydrogels prepared from their combination were assessed for hemostatic capability using swine whole blood clotting analysis. Initial screening showed efficient coagulative properties from κ-carrageenan and its carboxymethylated form, and α-chitosan, even compared to commercial products like QuikClot Zeolite Powder. Blending natural and synthetic polymers formed into hydrogels using gamma radiation produced materials with improved properties. KC and CMKC hydrogels were found to have the lowest blood clotting index in granulated form and had the higher capacity for platelet adhesion in foamed form compared to GelFoam. Possible mechanisms involved in the evident thrombogenicity of the materials include adsorption of platelets and related proteins that aid in platelet activation (primary hemostasis), absorption of water to concentrate protein factors that control the coagulation cascade, contact activation by its negatively charged surface and the formation of gel-blood clots.

  5. NASA Releases 'NASA App HD' for iPad

    NASA Image and Video Library

    2012-07-06

    The NASA App HD invites you to discover a wealth of NASA information right on your iPad. The application collects, customizes and delivers an extensive selection of dynamically updated mission information, images, videos and Twitter feeds from various online NASA sources in a convenient mobile package. Come explore with NASA, now on your iPad. 2012 Updated Version - HD Resolution and new features. Original version published on Sept. 1, 2010.

  6. On the influence of zero-padding on the nonlinear operations in Quantitative Susceptibility Mapping

    PubMed Central

    Eskreis-Winkler, Sarah; Zhou, Dong; Liu, Tian; Gupta, Ajay; Gauthier, Susan A.; Wang, Yi; Spincemaille, Pascal

    2016-01-01

    Purpose Zero padding is a well-studied interpolation technique that improves image visualization without increasing image resolution. This interpolation is often performed as a last step before images are displayed on clinical workstations. Here, we seek to demonstrate the importance of zero padding before rather than after performing non-linear post-processing algorithms, such as Quantitative Susceptibility Mapping (QSM). To do so, we evaluate apparent spatial resolution, relative error and depiction of multiple sclerosis (MS) lesions on images that were zero padded prior to, in the middle of, and after the application of the QSM algorithm. Materials and Methods High resolution gradient echo (GRE) data were acquired on twenty MS patients, from which low resolution data were derived using k-space cropping. Pre-, mid-, and post-zero padded QSM images were reconstructed from these low resolution data by zero padding prior to field mapping, after field mapping, and after susceptibility mapping, respectively. Using high resolution QSM as the gold standard, apparent spatial resolution, relative error, and image quality of the pre-, mid-, and post-zero padded QSM images were measured and compared. Results Both the accuracy and apparent spatial resolution of the pre-zero padded QSM was higher than that of mid-zero padded QSM (p < 0.001; p < 0.001), which was higher than that of post-zero padded QSM (p < 0.001; p < 0.001). The image quality of pre-zero padded reconstructions was higher than that of mid- and post-zero padded reconstructions (p = 0.004; p < 0.001). Conclusion Zero padding of the complex GRE data prior to nonlinear susceptibility mapping improves image accuracy and apparent resolution compared to zero padding afterwards. It also provides better delineation of MS lesion geometry, which may improve lesion subclassification and disease monitoring in MS patients. PMID:27587225

  7. On the influence of zero-padding on the nonlinear operations in Quantitative Susceptibility Mapping.

    PubMed

    Eskreis-Winkler, Sarah; Zhou, Dong; Liu, Tian; Gupta, Ajay; Gauthier, Susan A; Wang, Yi; Spincemaille, Pascal

    2017-01-01

    Zero padding is a well-studied interpolation technique that improves image visualization without increasing image resolution. This interpolation is often performed as a last step before images are displayed on clinical workstations. Here, we seek to demonstrate the importance of zero padding before rather than after performing non-linear post-processing algorithms, such as Quantitative Susceptibility Mapping (QSM). To do so, we evaluate apparent spatial resolution, relative error and depiction of multiple sclerosis (MS) lesions on images that were zero padded prior to, in the middle of, and after the application of the QSM algorithm. High resolution gradient echo (GRE) data were acquired on twenty MS patients, from which low resolution data were derived using k-space cropping. Pre-, mid-, and post-zero padded QSM images were reconstructed from these low resolution data by zero padding prior to field mapping, after field mapping, and after susceptibility mapping, respectively. Using high resolution QSM as the gold standard, apparent spatial resolution, relative error, and image quality of the pre-, mid-, and post-zero padded QSM images were measured and compared. Both the accuracy and apparent spatial resolution of the pre-zero padded QSM was higher than that of mid-zero padded QSM (p<0.001; p<0.001), which was higher than that of post-zero padded QSM (p<0.001; p<0.001). The image quality of pre-zero padded reconstructions was higher than that of mid- and post-zero padded reconstructions (p=0.004; p<0.001). Zero padding of the complex GRE data prior to nonlinear susceptibility mapping improves image accuracy and apparent resolution compared to zero padding afterwards. It also provides better delineation of MS lesion geometry, which may improve lesion subclassification and disease monitoring in MS patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Improved Cardiac Proton Magnetic Resonance Spectroscopy at 3 T Using High Permittivity Pads.

    PubMed

    de Heer, Paul; Bizino, Maurice B; Versluis, Maarten J; Webb, Andrew G; Lamb, Hildo J

    2016-02-01

    The aim of this study was to determine whether high permittivity (HP) pads can be used to increase the signal-to-noise ratio (SNR) of cardiac proton magnetic resonance spectroscopy at 3 T, allowing faster data acquisition. The institutional review board approved the study protocol, and written informed consent was obtained from all participants. In 22 healthy volunteers, water-suppressed localized spectra were acquired in the interventricular septum without and with HP pads. The SNR and myocardial triglyceride content (MTGC) were measured without and with the HP pads, and the results were compared with a paired sample Student t test. Application of HP pads increased mean (SD) SNR from 27.9 (15.6) to 42.3 (24.4) (P < 0.0001), a mean gain of 60%. The acquisition time can thereby be reduced from just under 5 minutes to just under 2 minutes while maintaining the same SNR. The mean (SD) MTGC was 0.39% (0.17%) without pads and 0.38% (0.15%) with pads (P = 0.83) for the healthy volunteers, showing that no bias is introduced by using the pads. No difference in spectral linewidth was measured (P = 0.80), the values being 17.4 (4.9) Hz without and 17.1 (3.2) Hz with pads. Both transmit and receive maps showed increases in sensitivity due to the presence of the HP pads. High permittivity pads improve cardiac proton magnetic resonance spectroscopy at 3 T by increasing the SNR on average by 60%, which can be used to reduce data acquisition time significantly, allowing fast assessment of MTGC without compromising spectral quality. The SNR increase arises primarily from the increase in receive sensitivity of the phased array, which is more closely coupled to the body via the HP pads. In addition, the transmit efficiency is also increased, allowing shorter or lower power radiofrequency pulses.

  9. Morpheus Launch Pad Move

    NASA Image and Video Library

    2014-03-14

    CAPE CANAVERAL, Fla. – A flatbed truck carries the launch pad for the Project Morpheus prototype lander to a new location at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. The launch pad is being moved to a different location to support the next phase of flight testing. Morpheus completed its seventh free flight test on March 11. The 83-second test began at 3:41 p.m. EDT with the Morpheus lander launching from the ground over a flame trench and ascending to 580 feet. Morpheus then flew its fastest downrange trek at 30 mph, travelling farther than before, 837 feet. The lander performed a 42-foot divert to emulate a hazard avoidance maneuver before descending and touching down on Landing Site 2, at the northern landing pad inside the automated landing and hazard avoidance technology ALHAT hazard field. Morpheus landed within one foot of its intended target. Project Morpheus tests NASA’s ALHAT and an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to other planetary surfaces. The landing facility provides the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov/. Photo credit: NASA/Dimitri Gerondidakis

  10. Morpheus Launch Pad Move

    NASA Image and Video Library

    2014-03-14

    CAPE CANAVERAL, Fla. – Construction workers assist as a crane lowers a portion of the launch pad for the Project Morpheus prototype lander onto a transporter at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. The launch pad is being moved to a different location at the landing facility to support the next phase of flight testing. Morpheus completed its seventh free flight test on March 11. The 83-second test began at 3:41 p.m. EDT with the Morpheus lander launching from the ground over a flame trench and ascending to 580 feet. Morpheus then flew its fastest downrange trek at 30 mph, travelling farther than before, 837 feet. The lander performed a 42-foot divert to emulate a hazard avoidance maneuver before descending and touching down on Landing Site 2, at the northern landing pad inside the automated landing and hazard avoidance technology ALHAT hazard field. Morpheus landed within one foot of its intended target. Project Morpheus tests NASA’s ALHAT and an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to other planetary surfaces. The landing facility provides the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov/. Photo credit: NASA/Dimitri Gerondidakis

  11. Morpheus Launch Pad Move

    NASA Image and Video Library

    2014-03-14

    CAPE CANAVERAL, Fla. – Construction workers assist as a crane lowers a large portion of the launch pad for the Project Morpheus prototype lander onto a transporter at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. The launch pad is being moved to a different location at the landing facility to support the next phase of flight testing. Morpheus completed its seventh free flight test on March 11. The 83-second test began at 3:41 p.m. EDT with the Morpheus lander launching from the ground over a flame trench and ascending to 580 feet. Morpheus then flew its fastest downrange trek at 30 mph, travelling farther than before, 837 feet. The lander performed a 42-foot divert to emulate a hazard avoidance maneuver before descending and touching down on Landing Site 2, at the northern landing pad inside the automated landing and hazard avoidance technology ALHAT hazard field. Morpheus landed within one foot of its intended target. Project Morpheus tests NASA’s ALHAT and an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to other planetary surfaces. The landing facility provides the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov/. Photo credit: NASA/Dimitri Gerondidakis

  12. Morpheus Launch Pad Move

    NASA Image and Video Library

    2014-03-14

    CAPE CANAVERAL, Fla. – Construction workers assist as a crane is used to lift a large portion of the launch pad for the Project Morpheus prototype lander onto a transporter at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. The launch pad is being moved to a different location at the landing facility to support the next phase of flight testing. Morpheus completed its seventh free flight test on March 11. The 83-second test began at 3:41 p.m. EDT with the Morpheus lander launching from the ground over a flame trench and ascending to 580 feet. Morpheus then flew its fastest downrange trek at 30 mph, travelling farther than before, 837 feet. The lander performed a 42-foot divert to emulate a hazard avoidance maneuver before descending and touching down on Landing Site 2, at the northern landing pad inside the automated landing and hazard avoidance technology ALHAT hazard field. Morpheus landed within one foot of its intended target. Project Morpheus tests NASA’s ALHAT and an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to other planetary surfaces. The landing facility provides the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov/. Photo credit: NASA/Dimitri Gerondidakis

  13. Morpheus Launch Pad Move

    NASA Image and Video Library

    2014-03-14

    CAPE CANAVERAL, Fla. – A crane is used to lower the launch pad for the Project Morpheus prototype lander onto a new location at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. The launch pad was moved to a different location to support the next phase of flight testing. Morpheus completed its seventh free flight test on March 11. The 83-second test began at 3:41 p.m. EDT with the Morpheus lander launching from the ground over a flame trench and ascending to 580 feet. Morpheus then flew its fastest downrange trek at 30 mph, travelling farther than before, 837 feet. The lander performed a 42-foot divert to emulate a hazard avoidance maneuver before descending and touching down on Landing Site 2, at the northern landing pad inside the automated landing and hazard avoidance technology ALHAT hazard field. Morpheus landed within one foot of its intended target. Project Morpheus tests NASA’s ALHAT and an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to other planetary surfaces. The landing facility provides the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov/. Photo credit: NASA/Dimitri Gerondidakis

  14. Morpheus Launch Pad Move

    NASA Image and Video Library

    2014-03-14

    CAPE CANAVERAL, Fla. – Construction workers begin to reassemble the launch pad for the Project Morpheus prototype lander at a new location at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. The launch pad was moved to a different location to support the next phase of flight testing. Morpheus completed its seventh free flight test on March 11. The 83-second test began at 3:41 p.m. EDT with the Morpheus lander launching from the ground over a flame trench and ascending to 580 feet. Morpheus then flew its fastest downrange trek at 30 mph, travelling farther than before, 837 feet. The lander performed a 42-foot divert to emulate a hazard avoidance maneuver before descending and touching down on Landing Site 2, at the northern landing pad inside the automated landing and hazard avoidance technology ALHAT hazard field. Morpheus landed within one foot of its intended target. Project Morpheus tests NASA’s ALHAT and an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to other planetary surfaces. The landing facility provides the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov/. Photo credit: NASA/Dimitri Gerondidakis

  15. Morpheus Launch Pad Move

    NASA Image and Video Library

    2014-03-14

    CAPE CANAVERAL, Fla. – Construction workers attach a crane to part of the launch pad for the Project Morpheus prototype lander at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. The launch pad will be moved to a different location at the landing facility to support the next phase of flight testing. The seventh free flight test of Morpheus occurred on March 11. The 83-second test began at 3:41 p.m. EDT with the Morpheus lander launching from the ground over a flame trench and ascending to 580 feet. Morpheus then flew its fastest downrange trek at 30 mph, travelling farther than before, 837 feet. The lander performed a 42-foot divert to emulate a hazard avoidance maneuver before descending and touching down on Landing Site 2, at the northern landing pad inside the automated landing and hazard avoidance technology ALHAT hazard field. Morpheus landed within one foot of its intended target. Project Morpheus tests NASA’s ALHAT and an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to other planetary surfaces. The landing facility provides the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov/. Photo credit: NASA/Dimitri Gerondidakis

  16. Morpheus Launch Pad Move

    NASA Image and Video Library

    2014-03-14

    CAPE CANAVERAL, Fla. – Construction workers monitor the progress as a crane is used to lift a portion of the launch pad for the Project Morpheus prototype lander at the north end of the Shuttle Landing Facility at NASA’s Kennedy Space Center in Florida. The launch pad will be moved to a different location at the landing facility to support the next phase of flight testing. The seventh free flight test of Morpheus occurred on March 11. The 83-second test began at 3:41 p.m. EDT with the Morpheus lander launching from the ground over a flame trench and ascending to 580 feet. Morpheus then flew its fastest downrange trek at 30 mph, travelling farther than before, 837 feet. The lander performed a 42-foot divert to emulate a hazard avoidance maneuver before descending and touching down on Landing Site 2, at the northern landing pad inside the automated landing and hazard avoidance technology ALHAT hazard field. Morpheus landed within one foot of its intended target. Project Morpheus tests NASA’s ALHAT and an engine that runs on liquid oxygen and methane, or green propellants, into a fully-operational lander that could deliver cargo to other planetary surfaces . The landing facility provides the lander with the kind of field necessary for realistic testing, complete with rocks, craters and hazards to avoid. Morpheus’ ALHAT payload allows it to navigate to clear landing sites amidst rocks, craters and other hazards during its descent. Project Morpheus is being managed under the Advanced Exploration Systems, or AES, Division in NASA’s Human Exploration and Operations Mission Directorate. The efforts in AES pioneer new approaches for rapidly developing prototype systems, demonstrating key capabilities and validating operational concepts for future human missions beyond Earth orbit. For more information on Project Morpheus, visit http://morpheuslander.jsc.nasa.gov/. Photo credit: NASA/Dimitri Gerondidakis

  17. iPads: Improving Numeracy Learning in the Early Years

    ERIC Educational Resources Information Center

    Spencer, Peta

    2013-01-01

    The concept of mobile technologies is now an emergency theme in educational research, yet the playing of these edutainment applications and their impact on early childhood learning needs to be fully explored. This study highlights current research and explores how iPads improve student learning. It also examines how the introduction of iPads,…

  18. iPad Use and Student Engagement in the Classroom

    ERIC Educational Resources Information Center

    Mango, Oraib

    2015-01-01

    iPads and handheld digital devices have been securing their place in educational institutions surrounded by debates between advocates and skeptics. In light of not enough evidence supporting the use of iPads in education, this study examined the ways that college students in two foreign language classrooms perceived the influence of the use of…

  19. ImagePAD, a novel counting application for the Apple iPad, used to quantify axons in the mouse optic nerve.

    PubMed

    Templeton, Justin P; Struebing, Felix L; Lemmon, Andrew; Geisert, Eldon E

    2014-11-01

    The present article introduces a new and easy to use counting application for the Apple iPad. The application "ImagePAD" takes advantage of the advanced user interface features offered by the Apple iOS platform, simplifying the rather tedious task of quantifying features in anatomical studies. For example, the image under analysis can be easily panned and zoomed using iOS-supported multi-touch gestures without losing the spatial context of the counting task, which is extremely important for ensuring count accuracy. This application allows one to quantify up to 5 different types of objects in a single field and output the data in a tab-delimited format for subsequent analysis. We describe two examples of the use of the application: quantifying axons in the optic nerve of the C57BL/6J mouse and determining the percentage of cells labeled with NeuN or ChAT in the retinal ganglion cell layer. For the optic nerve, contiguous images at 60× magnification were taken and transferred onto an Apple iPad. Axons were counted by tapping on the touch-sensitive screen using ImagePAD. Nine optic nerves were sampled and the number of axons in the nerves ranged from 38,872 axons to 50,196 axons with an average of 44,846 axons per nerve (SD = 3980 axons). Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Pad 39B Flame Trench Upgrades and modifications

    NASA Image and Video Library

    2016-03-03

    Upgrades and modifications continue to the flame trench at Launch Pad 39B at NASA’s Kennedy Space Center in Florida. Pad B is being refurbished to support the launch of NASA’s Space Launch System rocket. The Ground Systems Development and Operations (GSDO) Program at Kennedy is helping transform the space center into a multi-user spaceport and prepare for Exploration Mission-1, deep-space missions, and the journey to Mars.

  1. Effect of Gender on Mechanical Properties of the Plantar Fascia and Heel Fat Pad.

    PubMed

    Taş, Serkan

    2017-10-01

    The purpose of the study was to investigate the plantar fascia and heel fat pad stiffness and thickness parameters in females and compare these values with those of males. This study was carried out in 60 healthy sedentary participants (30 female, 30 male) between the ages of 19 and 50 years. Shear wave velocity (SWV) and thickness of the plantar fascia and heel fat pad were measured with an ultrasonography device. Males had a higher plantar fascia ( P = .037) and heel fat pad ( P = .001) thickness compared with females, but SWV of the plantar fascia ( P = .673), heel fat pad microchamber layer ( P = .240), and heel fat pad macrochamber layer ( P = .636) were similar in both groups. Body mass had a strong correlation with the plantar fascia ( r = 0.64, P < .001) and heel fat pad thickness ( r = 0.68, P < .001). Height had a moderate correlation with the plantar fascia ( r = 0.44, P < .001) and heel fat pad thickness ( r = 0.42, P = .001). Plantar fascia and heel fat pad stiffness were similar in both genders; however, females had a lower plantar fascia and heel fat pad thickness compared with males. Correlation analysis results suggest that higher plantar fascia and heel fat pad thickness in males may be related to higher body mass and height. Level III, Retrospective comparative study.

  2. Pad-mode-induced instantaneous mode instability for simple models of brake systems

    NASA Astrophysics Data System (ADS)

    Oberst, S.; Lai, J. C. S.

    2015-10-01

    Automotive disc brake squeal is fugitive, transient and remains difficult to predict. In particular, instantaneous mode squeal observed experimentally does not seem to be associated with mode coupling and its mechanism is not clear. The effects of contact pressures, friction coefficients as well as material properties (pressure and temperature dependency and anisotropy) for brake squeal propensity have not been systematically explored. By analysing a finite element model of an isotropic pad sliding on a plate similar to that of a previously reported experimental study, pad modes have been identified and found to be stable using conventional complex eigenvalue analysis. However, by subjecting the model to contact pressure harmonic excitation for a range of pressures and friction coefficients, a forced response analysis reveals that the dissipated energy for pad modes is negative and becomes more negative with increasing contact pressures and friction coefficients, indicating the potential for instabilities. The frequency of the pad mode in the sliding direction is within the range of squeal frequencies observed experimentally. Nonlinear time series analysis of the vibration velocity also confirms the evolution of instabilities induced by pad modes as the friction coefficient increases. By extending this analysis to a more realistic but simple brake model in the form of a pad-on-disc system, in-plane pad-modes, which a complex eigenvalue analysis predicts to be stable, have also been identified by negative dissipated energy for both isotropic and anisotropic pad material properties. The influence of contact pressures on potential instabilities has been found to be more dominant than changes in material properties owing to changes in pressure or temperature. Results here suggest that instantaneous mode squeal is likely caused by in-plane pad-mode instabilities.

  3. Engaging Preservice Teachers in Professional Development about iPads

    ERIC Educational Resources Information Center

    Shannon, Katheryn E.; Cullen, Theresa A.

    2016-01-01

    The iEducate mini-conference was a professional development approach used in a college of education that has a one to one iPad initiative. Students were strongly encouraged to attend workshops on effective iPad integration strategies for the classroom during a one-week period. A total of 87 students, faculty, staff, alumni, and community members…

  4. Identification of a second PAD1 in Brettanomyces bruxellensis LAMAP2480.

    PubMed

    González, Camila; Godoy, Liliana; Ganga, Ma Angélica

    2017-02-01

    Volatile phenols are aromatic compounds produced by some yeasts of the genus Brettanomyces as defense against the toxicity of hydroxycinnamic acids (p-coumaric acid, ferulic acid and caffeic acid). The origin of these compounds in winemaking involves the sequential action of two enzymes: coumarate decarboxylase and vinylphenol reductase. The first one converts hydroxycinnamic acids into hydroxystyrenes, which are then reduced to ethyl derivatives by vinylphenol reductase. Volatile phenols derived from p-coumaric acid (4-vinylphenol and 4-ethylphenol) have been described as the major contributors to self-defeating aromas associated with stable, gouache, wet mouse, etc., which generates large economic losses in the wine industry. The gene responsible for the production of 4-vinylphenol from p-coumaric acid has been identified as PAD1, which encodes a phenylacrylic acid decarboxylase. PAD1 has been described for many species, among them Candida albicans, Candida dubliniensis, Debaryomyces hansenii and Pichia anomala. In Brettanomyces bruxellensis LAMAP2480, a 666 bp reading frame (DbPAD) encodes a coumarate decarboxylase. Recent studies have reported the existence of a new reading frame belonging to DbPAD called DbPAD2 of 531 bp, which could encode a protein with similar enzymatic activity to PAD1. The present study confirmed that the transformation of Saccharomyces cerevisiae strain BY4722 with reading frame DbPAD2 under the control of the B. bruxellensis ACT1 promoter, encodes an enzyme with coumarate decarboxylase activity. This work has provided deeper insight into the origin of aroma defects in wine due to contamination by Brettanomyces spp.

  5. Use of neoprene pads in testing concrete cylinders : final report.

    DOT National Transportation Integrated Search

    1982-01-01

    This study investigated the feasibility of using neoprene pads confined by steel end caps instead of sulfur-mortar caps in compressive strength tests on concrete cylinders. The 1/2 in. (13 mm) thick neoprene pads had a 50 durometer hardness and were ...

  6. Fibrin, γ’-fibrinogen, and trans-clot pressure gradient control hemostatic clot growth during human blood flow over a collagen/tissue factor wound

    PubMed Central

    Muthard, Ryan W.; Welsh, John D.; Brass, Lawrence F.; Diamond, Scott L.

    2015-01-01

    SUMMARY Objective Biological and physical factors interact to modulate blood response in a wounded vessel, resulting in a hemostatic clot or an occlusive thrombus. Flow and pressure differential (ΔP) across the wound from the lumen to the extravascular compartment may impact hemostasis and the observed core/shell architecture. We examined physical and biological factors responsible for regulating thrombin mediated clot growth. Approach and Results Using factor XIIa-inhibited human whole blood perfused in a microfluidic device over collagen/tissue factor at controlled wall shear rate and ΔP, we found thrombin to be highly localized in the P-selectin+ core of hemostatic clots. Increasing ΔP from 9 to 29 mm-Hg (wall shear rate = 400 s−1) reduced P-selectin+ core size and total clot size due to enhanced extravasation of thrombin. Blockade of fibrin polymerization with 5 mM GPRP dysregulated hemostasis by enhancing both P-selectin+ core size and clot size at 400 s−1 (20 mm-Hg). For whole blood flow (no GPRP), the thickness of the P-selectin-negative shell was reduced under arterial conditions (2000 s−1, 20 mm-Hg). Consistent with the antithrombin-1 activity of fibrin implicated with GPRP, anti-γ’-fibrinogen antibody enhanced core-localized thrombin, core size, and overall clot size, especially at venous (100 s−1) but not arterial wall shear rates (2000 s−1). Pathological shear (15,000 s−1) and GPRP synergized to exacerbate clot growth. Conclusions Hemostatic clotting was dependent on core-localized thrombin that (1) triggered platelet P-selectin display and (2) was highly regulated by fibrin and the trans-clot ΔP. Also, γ’-fibrinogen had a role in venous but not arterial conditions. PMID:25614284

  7. 41. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM LAUNCHER; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM LAUNCHER; SOUTH FACE OF MST IN BACKGROUND. RAIL SYSTEM FROM BASE OF MST PARALLEL TO MAST. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  8. Arachnids Secrete a Fluid over Their Adhesive Pads

    PubMed Central

    Peattie, Anne M.; Dirks, Jan-Henning; Henriques, Sérgio; Federle, Walter

    2011-01-01

    Background Many arachnids possess adhesive pads on their feet that help them climb smooth surfaces and capture prey. Spider and gecko adhesives have converged on a branched, hairy structure, which theoretically allows them to adhere solely by dry (solid-solid) intermolecular interactions. Indeed, the consensus in the literature is that spiders and their smooth-padded relatives, the solifugids, adhere without the aid of a secretion. Methodology and Principal Findings We investigated the adhesive contact zone of living spiders, solifugids and mites using interference reflection microscopy, which allows the detection of thin liquid films. Like insects, all the arachnids we studied left behind hydrophobic fluid footprints on glass (mean refractive index: 1.48–1.50; contact angle: 3.7–11.2°). Fluid was not always secreted continuously, suggesting that pads can function in both wet and dry modes. We measured the attachment forces of single adhesive setae from tarantulas (Grammostola rosea) by attaching them to a bending beam with a known spring constant and filming the resulting deflection. Individual spider setae showed a lower static friction at rest (26%±2.8 SE of the peak friction) than single gecko setae (Thecadactylus rapicauda; 96%±1.7 SE). This may be explained by the fact that spider setae continued to release fluid after isolation from the animal, lubricating the contact zone. Significance This finding implies that tarsal secretions occur within all major groups of terrestrial arthropods with adhesive pads. The presence of liquid in an adhesive contact zone has important consequences for attachment performance, improving adhesion to rough surfaces and introducing rate-dependent effects. Our results leave geckos and anoles as the only known representatives of truly dry adhesive pads in nature. Engineers seeking biological inspiration for synthetic adhesives should consider whether model species with fluid secretions are appropriate to their design goals

  9. Friction and Braking Application of Unhazardous Palm Slag Brake Pad Composite

    NASA Astrophysics Data System (ADS)

    Khoni, Norizzahthul Ainaa Abdul; Ruzaidi Ghazali, Che Mohd; Bakri Abdullah, Mohd Mustafa Al

    2018-03-01

    This paper reveals new alternative friction materials for brake pads. Palm slag was studied as new friction materials in brake pads but its much harder made it difficult to be applied. As a way to reduce the hardness, tire dust was including as purpose on stabilizing the hardness of brake pads. The palm slag was sieves to get desired size that is 150 μm, 300 μm and 600 μm. The percentage weight of materials used are 20% graphite, 20% aluminium oxide, 20% steel fiber, 20% polyester resin and another 40% are varied between tire dust and palm slag. All of materials were blend and compress by using hot pressed machine. The composites properties that were examined are density, porosity, hardness, compressive strength, microstructure analysis and wear rate. The composition of 30% palm slag, 10% tire dust and larger size of filler give better result of mechanical properties and less wear rate of brake pads composites. Then, palm slag can be used in producing of non asbestos brake pads.

  10. STS-127 Pad Security

    NASA Image and Video Library

    2009-07-11

    NASA Kennedy Space Center Security Officer, Jack "Supr Jac" Hilderbrand talks on the phone at the security gate to Pad 39a just a day shy of his 70th birthday and the planned launch of the space shuttle Endeavour with the STS-127 crew. Hilderbrand has been working for the space program since 1960. Photo Credit: (NASA/Bill Ingalls)

  11. Implementation Factors and Faculty Perceptions of Electronic Textbooks on the iPad

    ERIC Educational Resources Information Center

    Rogers-Estable, Michelle Dawn

    2018-01-01

    A federally managed university in the United Arab Emirates implemented a one-to-one iPad program. In an effort to increase access to interactive digital learning resources on the iPads, they next transitioned from paperbased textbooks (pTexts) to electronic textbooks (eTexts) on the iPad for all course delivery formats. The goal of this study was…

  12. 42. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM MST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM MST BASE. LAUNCHER IS BEHIND UMBILICAL MAST AND RAIL SYSTEM IS PARALLEL TO MAST ON RIGHT AND LEFT. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  13. Humidity-enhanced wet adhesion on insect-inspired fibrillar adhesive pads

    PubMed Central

    Xue, Longjian; Kovalev, Alexander; Eichler-Volf, Anna; Steinhart, Martin; Gorb, Stanislav N.

    2015-01-01

    Many insect species reversibly adhere to surfaces by combining contact splitting (contact formation via fibrillar contact elements) and wet adhesion (supply of liquid secretion via pores in the insects’ feet). Here, we fabricate insect-inspired fibrillar pads for wet adhesion containing continuous pore systems through which liquid is supplied to the contact interfaces. Synergistic interaction of capillarity and humidity-induced pad softening increases the pull-off force and the work of adhesion by two orders of magnitude. This increase and the independence of pull-off force on the applied load are caused by the capillarity-supported formation of solid–solid contact between pad and the surface. Solid–solid contact dominates adhesion at high humidity and capillarity at low humidity. At low humidity, the work of adhesion strongly depends on the amount of liquid deposited on the surface and, therefore, on contact duration. These results may pave the way for the design of insect-inspired adhesive pads. PMID:25791574

  14. Padé Approximant and Minimax Rational Approximation in Standard Cosmology

    NASA Astrophysics Data System (ADS)

    Zaninetti, Lorenzo

    2016-02-01

    The luminosity distance in the standard cosmology as given by $\\Lambda$CDM and consequently the distance modulus for supernovae can be defined by the Pad\\'e approximant. A comparison with a known analytical solution shows that the Pad\\'e approximant for the luminosity distance has an error of $4\\%$ at redshift $= 10$. A similar procedure for the Taylor expansion of the luminosity distance gives an error of $4\\%$ at redshift $=0.7 $; this means that for the luminosity distance, the Pad\\'e approximation is superior to the Taylor series. The availability of an analytical expression for the distance modulus allows applying the Levenberg--Marquardt method to derive the fundamental parameters from the available compilations for supernovae. A new luminosity function for galaxies derived from the truncated gamma probability density function models the observed luminosity function for galaxies when the observed range in absolute magnitude is modeled by the Pad\\'e approximant. A comparison of $\\Lambda$CDM with other cosmologies is done adopting a statistical point of view.

  15. Attenuated pediatric electrode pads for automated external defibrillator use in children.

    PubMed

    Atkins, Dianne L; Jorgenson, Dawn B

    2005-07-01

    This post-market, observational study is intended to evaluate reported uses of pediatric pads that reduce the energy delivered by some adult automated external defibrillators (AEDs) so that they may be used with pediatric patients. Users of the pediatric pads were asked to report any use of the pads, even if no shock was delivered and to provide detailed information about the event, caregiver and the patient. Reports of the use of pediatric pads have been received and confirmed for 27 patients, age range 0 days to 23 years, median 2 years. Ventricular fibrillation (VF) was reported in eight cases, age range 4.5 months to 10 years, median 3 years. Shocks were delivered to all VF patients, the average shock number was 1.9, range 1-4. All patients had termination of VF, were admitted to the hospital and five survived to hospital discharge. Non-shockable rhythms were reported in 16 patients, and the AED appropriately did not advise a shock. Eleven of these patients had asystole or PEA as their initial rhythm and did not survive to hospital discharge. One report contained no additional information other than that the patient did not survive, and in two other reports, the pads were not applied to patients. Voluntary reports of the use of attenuated pediatric defibrillation pads indicate the devices performed appropriately. All eight VF patients had termination of VF and five survived to hospital discharge. These data support the rapid deployment of AEDs for young children as well as adolescents and adults. Since the pediatric pads are available and deliver an appropriate dose for children, their use should be strongly encouraged.

  16. Dew point effect of cooled hydrogel pads on human stratum corneum biosurface.

    PubMed

    Xhauflaire-Uhoda, Emmanuelle; Paquet, Philippe; Piérard, Gérald E

    2008-01-01

    Cooled hydrogel pads are used to prevent overheating effects of laser therapy. They do not induce cold injuries to the skin, but their more subtle physiological effects have not been thoroughly studied. To describe the changes in transepidermal water loss and electrometric properties of the skin surface following application of cooled hydrogel pads. Measurements were performed on normal forearm skin of 27 healthy volunteers and on freshly excised skin from abdominoplasty. LaserAid hydrogel pads cooled to 4 degrees C were placed for 15 min on the forearm skin. Measurements of transepidermal water loss (TEWL) and electrometric properties (Corneometer, Nova DPM 900) were performed before application and after removal of the cooled pads. A consistent increase in corneometer units, dermal phase meter (DPM) values and TEWL were recorded at removal of the cooled hydrogel pads. Both the in vivo and in vitro assessments brought similar information. The similar changes disclosed in vitro and in vivo suggest that a common physical process is operating in these conditions. The observed phenomenon is opposite to the predicted events given by the Arrhenius law probably because of the combination of cooling and occlusion by the pads. A dew point effect (air temperature at which relative humidity is maximal) is likely involved in the moisture content of the stratum corneum. Thus, the biological impact of using cooling hydrogel pads during laser therapy is different from the effect of a cryogenic spray cooling procedure. The better preservation of the water balance in the stratum corneum by the cooled hydrogel pads could have a beneficial esthetic effect on laser treated areas. (c) 2008 S. Karger AG, Basel.

  17. Sanitary pad interventions for girls' education in Ghana: a pilot study.

    PubMed

    Montgomery, Paul; Ryus, Caitlin R; Dolan, Catherine S; Dopson, Sue; Scott, Linda M

    2012-01-01

    Increased education of girls in developing contexts is associated with a number of important positive health, social, and economic outcomes for a community. The event of menarche tends to coincide with girls' transitions from primary to secondary education and may constitute a barrier for continued school attendance and performance. Following the MRC Framework for Complex Interventions, a pilot controlled study was conducted in Ghana to assess the role of sanitary pads in girls' education. A sample of 120 schoolgirls between the ages of 12 and 18 from four villages in Ghana participated in a non-randomized trial of sanitary pad provision with education. The trial had three levels of treatment: provision of pads with puberty education; puberty education alone; or control (no pads or education). The primary outcome was school attendance. After 3 months, providing pads with education significantly improved attendance among participants, (lambda 0.824, F = 3.760, p<.001). After 5 months, puberty education alone improved attendance to a similar level (M = 91.26, SD = 7.82) as sites where pads were provided with puberty education (Rural M = 89.74, SD = 9.34; Periurban M = 90.54, SD = 17.37), all of which were higher than control (M = 84.48, SD = 12.39). The total improvement through pads with education intervention after 5 months was a 9% increase in attendance. After 3 months, providing pads with education significantly improved attendance among participants. The changes in attendance at the end of the trial, after 5 months, were found to be significant by site over time. With puberty education alone resulting in a similar attendance level. This pilot study demonstrated promising results of a low-cost, rapid-return intervention for girls' education in a developing context. Given the considerable development needs of poorer countries and the potential of young women there, these results suggest that a large-scale cluster randomized

  18. Sanitary Pad Interventions for Girls' Education in Ghana: A Pilot Study

    PubMed Central

    Montgomery, Paul; Ryus, Caitlin R.; Dolan, Catherine S.; Dopson, Sue; Scott, Linda M.

    2012-01-01

    Background Increased education of girls in developing contexts is associated with a number of important positive health, social, and economic outcomes for a community. The event of menarche tends to coincide with girls' transitions from primary to secondary education and may constitute a barrier for continued school attendance and performance. Following the MRC Framework for Complex Interventions, a pilot controlled study was conducted in Ghana to assess the role of sanitary pads in girls' education. Methods A sample of 120 schoolgirls between the ages of 12 and 18 from four villages in Ghana participated in a non-randomized trial of sanitary pad provision with education. The trial had three levels of treatment: provision of pads with puberty education; puberty education alone; or control (no pads or education). The primary outcome was school attendance. Results After 3 months, providing pads with education significantly improved attendance among participants, (lambda 0.824, F = 3.760, p<.001). After 5 months, puberty education alone improved attendance to a similar level (M = 91.26, SD = 7.82) as sites where pads were provided with puberty education (Rural M = 89.74, SD = 9.34; Periurban M = 90.54, SD = 17.37), all of which were higher than control (M = 84.48, SD = 12.39). The total improvement through pads with education intervention after 5 months was a 9% increase in attendance. After 3 months, providing pads with education significantly improved attendance among participants. The changes in attendance at the end of the trial, after 5 months, were found to be significant by site over time. With puberty education alone resulting in a similar attendance level. Conclusion This pilot study demonstrated promising results of a low-cost, rapid-return intervention for girls' education in a developing context. Given the considerable development needs of poorer countries and the potential of young women there, these results suggest

  19. The floating cardiac fat pad-sign of occult pneumothorax.

    PubMed

    Kaufman, Claire; Bokhari, S A Jamal

    2016-08-01

    Pneumothoraces are a possible sequela of chest trauma with potential morbidity and mortality if not recognized and treated promptly. A portable supine chest radiograph is frequently the first radiologic study performed in the setting of trauma. While large pneumothoraces can be readily recognized on these radiographs, smaller pneumothoraces are missed in up to 15 % of trauma patients. There are many radiographic signs of occult pneumothoraces, and we are presenting a new radiographic sign of occult pneumothorax. The floating cardiac fat pad sign occurs when pleural air collects anteriorly and superiorly in the most non-dependent portion of the chest lifting the pericardial fat pad off the diaphragm. Lung markings are still seen surrounding the pericardial fat pad due to the inflated lower lobe of the lung resting dependently. Rapid and accurate identification of pneumothoraces is critical but often difficult on chest radiographs. Although there are many existing radiographic signs for identification of pneumothorax, prospective identification of small pneumothoraces is still relatively poor. Here, we describe an additional sign which aides in the detection of pneumothoraces, the floating cardiac fat pad. When present, this should prompt further evaluation with chest CT or upright chest radiograph.

  20. An inverse finite-element model of heel-pad indentation.

    PubMed

    Erdemir, Ahmet; Viveiros, Meredith L; Ulbrecht, Jan S; Cavanagh, Peter R

    2006-01-01

    A numerical-experimental approach has been developed to characterize heel-pad deformation at the material level. Left and right heels of 20 diabetic subjects and 20 nondiabetic subjects matched for age, gender and body mass index were indented using force-controlled ultrasound. Initial tissue thickness and deformation were measured using M-mode ultrasound; indentation forces were recorded simultaneously. An inverse finite-element analysis of the indentation protocol using axisymmetric models adjusted to reflect individual heel thickness was used to extract nonlinear material properties describing the hyperelastic behavior of each heel. Student's t-tests revealed that heel pads of diabetic subjects were not significantly different in initial thickness nor were they stiffer than those from nondiabetic subjects. Another heel-pad model with anatomically realistic surface representations of the calcaneus and soft tissue was developed to estimate peak pressure prediction errors when average rather than individualized material properties were used. Root-mean-square errors of up to 7% were calculated, indicating the importance of subject-specific modeling of the nonlinear elastic behavior of the heel pad. Indentation systems combined with the presented numerical approach can provide this information for further analysis of patient-specific foot pathologies and therapeutic footwear designs.

  1. Impact of the rail-pad multi-discrete model upon the prediction of the rail response

    NASA Astrophysics Data System (ADS)

    Mazilu, T.; Leu, M.

    2017-08-01

    Wheel/rail vibration has many technical effects such as wear of the rolling surfaces, rolling noise, settlement of the ballast and subgrade etc. This vibration is depending on the rail pad characteristic and subsequently, it is important to have an accurate overview on the relation between the rail pad characteristic and the level of the wheel/rail vibration. To this end, much theoretical and experimental research has been developed in the past, and for the theoretical approach the track model, in general, and, particularly, the rail pad model is of crucial importance. Usually, the rail pad model is discrete model one, neglecting the length of the rail pad. This fact is questionable because the sleepers span is only 4 times the rail pad length. Using the rail pad discrete model, the rail response is overestimated when the frequency of the excitation equals the pinned-pinned resonance frequency. In this paper, a multi-discrete model for the rail pad, consisting in many Kelvin-Voigt parallel systems, is inserted into an analytical model of the track. The track model is reduced to a rail taken as infinite Timoshenko beam, discretely supported via rail pad, sleeper and ballast. The influence of the number of Kelvin-Voigt systems of the rail pad model on the rail response is analysed.

  2. Children's Use of iPads in Outdoor Environmental Education Programs

    ERIC Educational Resources Information Center

    Kacoroski, Joy; Liddicoat, Kendra R.; Kerlin, Steve

    2016-01-01

    This exploratory study aimed to understand how use of digital technology, specifically iPads, impacts the learning experiences of children during outdoor environmental education programs. iPads were integrated into water quality education programs for fifth grade students from an urban area. Qualitative observations were analyzed to document…

  3. Hemostatic Changes Associated With Increased Mortality Rates in Hospitalized Patients With HIV-Associated Tuberculosis: A Prospective Cohort Study

    PubMed Central

    Schutz, Charlotte; Ward, Amy M.; Huson, Mischa A. M.; Wilkinson, Robert J.; Burton, Rosie; Maartens, Gary; Wilkinson, Katalin A.; Meijers, Joost C. M.; Lutter, René; Grobusch, Martin P.; Meintjes, Graeme; van der Poll, Tom

    2017-01-01

    Background Mortality rates remain high for human immunodeficiency virus (HIV)–associated tuberculosis, and our knowledge of contributing mechanisms is limited. We aimed to determine whether hemostatic changes in HIV-tuberculosis were associated with mortality or decreased survival time and the contribution of mycobacteremia to these effects. Methods We conducted a prospective study in Khayelitsha, South Africa, in hospitalized HIV-infected patients with CD4 cell counts <350/µL and microbiologically proved tuberculosis. HIV-infected outpatients without tuberculosis served as controls. Plasma biomarkers reflecting activation of procoagulation and anticoagulation, fibrinolysis, endothelial cell activation, matricellular protein release, and tissue damage were measured at admission. Cox proportional hazard models were used to assess variables associated with 12-week mortality rates. Results Of 59 patients with HIV-tuberculosis, 16 (27%) died after a median of 12 days (interquartile range, 0–24 days); 29 (64%) of the 45 not receiving anticoagulants fulfilled criteria for disseminated intravascular coagulation. Decreased survival time was associated with higher concentrations of markers of fibrinolysis, endothelial activation, matricellular protein release, and tissue damage and with decreased concentrations for markers of anticoagulation. In patients who died, coagulation factors involved in the common pathway were depleted (factor II, V, X), which corresponded to increased plasma clotting times. Mycobacteremia modestly influenced hemostatic changes without affecting mortality. Conclusions Patients with severe HIV-tuberculosis display a hypercoagulable state and activation of the endothelium, which is associated with mortality. PMID:28363198

  4. Application and Utility of iPads in Pediatric Tele-echocardiography.

    PubMed

    Colombo, Jamie N; Seckeler, Michael D; Barber, Brent J; Krupinski, Elizabeth A; Weinstein, Ronald S; Sisk, David; Lax, Daniela

    2016-05-01

    Telemedicine is used with increasing frequency to improve patient care in remote areas. The interpretation of medical imaging on iPad(®) (Apple, Cupertino, CA) tablets has been reported to be accurate. There are no studies on the use of iPads for interpretation of pediatric echocardiograms. We compared the quality of echo images, diagnostic accuracy, and review time using three different modalities: remote access on an iPad Air (iPad), remote access via a computer (Remote), and direct access on a computer linked through Ethernet to the server, the "gold standard" (Direct). Fifty consecutive archived pediatric echocardiograms were interpreted using the three modalities. Studies were analyzed blindly by three pediatric cardiologists; review time, diagnostic accuracy, and image quality were documented. Diagnostic accuracy was assessed by comparing the study diagnoses with the official diagnosis in the patient's chart. Discrepancies between diagnoses were graded as major (more than one grade difference) or minor (one grade difference in severity of lesion). There were no significant differences in accuracy among the three modalities. There was one major discrepancy (size of patent ductus arteriosus); all others were minor, hemodynamically insignificant. Image quality ratings were better for iPad than Remote; Direct had the highest ratings. Review times (mean [standard deviation] minutes) were longest for iPad (5.89 [3.87]) and then Remote (4.72 [2.69]), with Direct having the shortest times (3.52 [1.42]) (p < 0.0001). Pediatric echocardiograms can be interpreted using convenient, portable devices while preserving accuracy and quality with slightly longer review times (1-2 min). These findings are important in the current era of increasing need for mobile health.

  5. Comparison of skin microvascular reactivity with hemostatic markers of endothelial dysfunction and damage in type 2 diabetes

    PubMed Central

    Beer, Sandra; Feihl, François; Ruiz, Juan; Juhan-Vague, Irène; Aillaud, Marie-Françoise; Wetzel, Sandrine Golay; Liaudet, Lucas; Gaillard, Rolf C; Waeber, Bernard

    2008-01-01

    Aim: Patients with non-insulin-dependent diabetes mellitus (NIDDM) are at increased cardiovascular risk due to an accelerated atherosclerotic process. The present study aimed to compare skin microvascular function, pulse wave velocity (PWV), and a variety of hemostatic markers of endothelium injury [von Willebrand factor (vWF), plasminogen activator inhibitor-1 (PAI-1), tissue plasminogen activator (t-PA), tissue factor pathway inhibitor (TFPI), and the soluble form of thrombomodulin (s-TM)] in patients with NIDDM. Methods: 54 patients with NIDDM and 38 sex- and age-matched controls were studied. 27 diabetics had no overt micro- and/or macrovascular complications, while the remainder had either or both. The forearm skin blood flow was assessed by laser-Doppler imaging, which allowed the measurement of the response to iontophoretically applied acetylcholine (endothelium-dependent vasodilation) and sodium nitroprusside (endothelium-independent vasodilation), as well as the reactive hyperemia triggered by the transient occlusion of the circulation. Results: Both endothelial and non-endothelial reactivity were significantly blunted in diabetics, regardless of the presence or the absence of vascular complications. Plasma vWF, TFPI and s-TM levels were significantly increased compared with controls only in patients exhibiting vascular complications. Concentrations of t-PA and PAI-1 were significantly increased in the two groups of diabetics versus controls. Conclusion: In NIDDM, both endothelium-dependent and -independent microvascular skin reactivity are impaired, whether or not underlying vascular complications exist. It also appears that microvascular endothelial dysfunction is not necessarily associated in NIDDM with increased circulating levels of hemostatic markers of endothelial damage known to reflect a hypercoagulable state. PMID:19337558

  6. μ-PADs for detection of chemical warfare agents.

    PubMed

    Pardasani, Deepak; Tak, Vijay; Purohit, Ajay K; Dubey, D K

    2012-12-07

    Conventional methods of detection of chemical warfare agents (CWAs) based on chromogenic reactions are time and solvent intensive. The development of cost, time and solvent effective microfluidic paper based analytical devices (μ-PADs) for the detection of nerve and vesicant agents is described. The detection of analytes was based upon their reactions with rhodamine hydroxamate and para-nitrobenzyl pyridine, producing red and blue colours respectively. Reactions were optimized on the μ-PADs to produce the limits of detection (LODs) as low as 100 μM for sulfur mustard in aqueous samples. Results were quantified with the help of a simple desktop scanner and Photoshop software. Sarin achieved a linear response in the two concentration ranges of 20-100 mM and 100-500 mM, whereas the response of sulfur mustard was found to be linear in the concentration range of 10-75 mM. Results were precise enough to establish the μ-PADs as a valuable tool for security personnel fighting against chemical terrorism.

  7. Effects of sulfur-based hemostatic agents and gingival retraction cords handled with latex gloves on the polymerization of polyvinyl siloxane impression materials

    PubMed Central

    MACHADO, Carlos Eduardo Palhares; GUEDES, Carlos Gramani

    2011-01-01

    Objectives This study investigated the possible interactions between three addition silicone materials (Express®, Aquasil Ultra® and Adsil®), three hemostatic agents (ferric sulfate, StatGel FS®; aluminum sulfate, GelCord®; and aluminum chloride, Hemostop®) and gingival retraction cords previously handled with latex gloves to determine whether direct contact with medicaments or indirect contamination by latex in conditions similar to those found in clinical practice inhibit or affect the setting of the impression materials. Material and Methods A portable device for the simultaneous test of several specimens was specifically developed for this study. Polymerization inhibition was analyzed by examination of the impressions and the molded surface. Ten trials were performed for each addition silicone material used in the study, at a total of 240 study samples. Results All the samples tested (N=240) were nonreactive regardless of the type of combination used. Conclusions Aluminum sulfate, ferric sulfate and aluminum chloride hemostatic solutions did not show any inhibitory potential on the addition silicone samples under study, and there were no changes in polymerization as a result of contact between addition silicone and retraction cords handled with latex gloves. PMID:22230998

  8. Effects of sulfur-based hemostatic agents and gingival retraction cords handled with latex gloves on the polymerization of polyvinyl siloxane impression materials.

    PubMed

    Machado, Carlos Eduardo Palhares; Guedes, Carlos Gramani

    2011-01-01

    This study investigated the possible interactions between three addition silicone materials (Express®, Aquasil Ultra® and Adsil®), three hemostatic agents (ferric sulfate, StatGel FS®; aluminum sulfate, GelCord®; and aluminum chloride, Hemostop®) and gingival retraction cords previously handled with latex gloves to determine whether direct contact with medicaments or indirect contamination by latex in conditions similar to those found in clinical practice inhibit or affect the setting of the impression materials. A portable device for the simultaneous test of several specimens was specifically developed for this study. Polymerization inhibition was analyzed by examination of the impressions and the molded surface. Ten trials were performed for each addition silicone material used in the study, at a total of 240 study samples. All the samples tested (N=240) were nonreactive regardless of the type of combination used. Aluminum sulfate, ferric sulfate and aluminum chloride hemostatic solutions did not show any inhibitory potential on the addition silicone samples under study, and there were no changes in polymerization as a result of contact between addition silicone and retraction cords handled with latex gloves.

  9. The PAD Class: a new paradigm for university classroom teaching

    NASA Astrophysics Data System (ADS)

    Zhang, Xuexin

    2017-08-01

    The PAD Class (Presentation-Assimilation-Discussion) is a new paradigm for classroom teaching combining strengths of lecture and discussion. With half class time allocated for teacher's presentation and the other half for students' discussion, an assimilation stage was inserted between presentation and discussion for independent and individualized learning. Since its first success in 2014, the PAD method has gained national popularity in China and been successfully put into practice by thousands of college teachers in nearly all subjects, e.g., science, engineering, medical sciences, social sciences, humanities and arts. This paper analyzed the psychological and pedagogical rationales underlying the PAD Class to explicate its effectiveness in enhancing active learning.

  10. Improved determination of particulate absorption from combined filter pad and PSICAM measurements.

    PubMed

    Lefering, Ina; Röttgers, Rüdiger; Weeks, Rebecca; Connor, Derek; Utschig, Christian; Heymann, Kerstin; McKee, David

    2016-10-31

    Filter pad light absorption measurements are subject to two major sources of experimental uncertainty: the so-called pathlength amplification factor, β, and scattering offsets, o, for which previous null-correction approaches are limited by recent observations of non-zero absorption in the near infrared (NIR). A new filter pad absorption correction method is presented here which uses linear regression against point-source integrating cavity absorption meter (PSICAM) absorption data to simultaneously resolve both β and the scattering offset. The PSICAM has previously been shown to provide accurate absorption data, even in highly scattering waters. Comparisons of PSICAM and filter pad particulate absorption data reveal linear relationships that vary on a sample by sample basis. This regression approach provides significantly improved agreement with PSICAM data (3.2% RMS%E) than previously published filter pad absorption corrections. Results show that direct transmittance (T-method) filter pad absorption measurements perform effectively at the same level as more complex geometrical configurations based on integrating cavity measurements (IS-method and QFT-ICAM) because the linear regression correction compensates for the sensitivity to scattering errors in the T-method. This approach produces accurate filter pad particulate absorption data for wavelengths in the blue/UV and in the NIR where sensitivity issues with PSICAM measurements limit performance. The combination of the filter pad absorption and PSICAM is therefore recommended for generating full spectral, best quality particulate absorption data as it enables correction of multiple errors sources across both measurements.

  11. Towards reducing impact-induced brain injury: lessons from a computational study of army and football helmet pads.

    PubMed

    Moss, William C; King, Michael J; Blackman, Eric G

    2014-01-01

    We use computational simulations to compare the impact response of different football and U.S. Army helmet pad materials. We conduct experiments to characterise the material response of different helmet pads. We simulate experimental helmet impact tests performed by the U.S. Army to validate our methods. We then simulate a cylindrical impactor striking different pads. The acceleration history of the impactor is used to calculate the head injury criterion for each pad. We conduct sensitivity studies exploring the effects of pad composition, geometry and material stiffness. We find that (1) the football pad materials do not outperform the currently used military pad material in militarily relevant impact scenarios; (2) optimal material properties for a pad depend on impact energy and (3) thicker pads perform better at all velocities. Although we considered only the isolated response of pad materials, not entire helmet systems, our analysis suggests that by using larger helmet shells with correspondingly thicker pads, impact-induced traumatic brain injury may be reduced.

  12. Shock-Absorbing Effects of Various Padding Conditions in Improving Efficacy of Wrist Guards

    PubMed Central

    Hwang, Il-Kyu; Kim, Kyu-Jung

    2004-01-01

    The use of wrist guards has limited efficacy in preventing wrist injuries during falling in many sports activities. The objectives of this study were to measure the ground reaction force of the hand under simulated impact of the forearm and hand complex with different padding conditions of wrist guards and to analyze their impact force attenuation and maximum energy absorption for improved functional efficiency. A total of 15 subjects, wearing a commercial wrist guard, participated in a cable-released hand impact experiment to test four different conditions on the volar aspect of the hand, which include a wrist guard without a volar splint (bare hand), with a volar splint (normal use), with a volar splint and additional viscoelastic polymeric padding, and a volar splint and additional air cell padding. The ground reaction force and acceleration of the hand were measured using a force platform mounted on an anti-vibration table and a miniature accelerometer, respectively. Additional padding on the bare hand could substantially improve the maximum energy absorption by more than 39%, with no differences with each other. However, only the air cell padding could simultaneously improve the impact force attenuation by 32% compared with the bare hand impact without compromising the maximum energy absorption. It is recommended that common wrist guard design should provide more compliant padding in the volar aspect to improve the impact force attenuation through optimal material selection and design. Key Points The controversial efficacy of wrist guards in preventing wrist injuries during falling was tested through investigation of their impact force attenuation and maximum energy absorption from the measured ground reaction force of the hand under simulated impact of the forearm and hand complex with four different padding conditions of wrist guards: a wrist guard without a volar splint (bare hand), with a volar splint (normal use), with a volar splint and additional

  13. The Tablet Inscribed: Inclusive Writing Instruction with the iPad

    ERIC Educational Resources Information Center

    Sullivan, Rebecca M.

    2013-01-01

    Despite the author's initial skepticism, a classroom set of iPads has reinforced a student-directed approach to writing instruction, while also supporting an inclusive classroom. Using the iPads, students guide their writing process with access to the learning management system, electronic information resources, and an online text editor. Students…

  14. 21 CFR 884.5425 - Scented or scented deodorized menstrual pad.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Scented or scented deodorized menstrual pad. 884.5425 Section 884.5425 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... indicated conditions, but does not include menstrual pads treated with added antimicrobial agents or other...

  15. Measuring emissions from oil and natural gas well pads using the mobile flux plane technique.

    PubMed

    Rella, Chris W; Tsai, Tracy R; Botkin, Connor G; Crosson, Eric R; Steele, David

    2015-04-07

    We present a study of methane emissions from oil and gas producing well pad facilities in the Barnett Shale region of Texas, measured using an innovative ground-based mobile flux plane (MFP) measurement system, as part of the Barnett Coordinated Campaign.1 Using only public roads, we measured the emissions from nearly 200 well pads over 2 weeks in October 2013. The population of measured well pads is split into well pads with detectable emissions (N = 115) and those with emissions below the detection limit of the MFP instrument (N = 67). For those well pads with nonzero emissions, the distribution was highly skewed, with a geometric mean of 0.63 kg/h, a geometric standard deviation of 4.2, and an arithmetic mean of 1.72 kg/h. Including the population of nonemitting well pads, we find that the arithmetic mean of the well pads sampled in this study is 1.1 kg/h. This distribution implies that 50% of the emissions is due to the 6.6% highest emitting well pads, and 80% of the emissions is from the 22% highest emitting well pads.

  16. Pad 39B Flame Trench Brick Work

    NASA Image and Video Library

    2016-10-26

    Progress continues on the new flame trench at Launch Pad 39B at NASA's Kennedy Space Center in Florida. Construction workers with J.P. Donovan of Rockledge, Florida, prepare new heat-resistant bricks for installation on the north side of the flame trench. The Pad B flame trench is being refurbished to support the launch of NASA’s Space Launch System rocket. The Ground Systems Development and Operations (GSDO) Program at Kennedy is helping transform the space center into a multi-user spaceport and prepare for Exploration Mission 1, deep space missions, and NASA's Journey to Mars. For more information about GSDO, visit: http://www.nasa.gov/groundsystems.

  17. Pad 39B Flame Trench Brick Work

    NASA Image and Video Library

    2016-10-26

    Progress continues on the new flame trench at Launch Pad 39B at NASA's Kennedy Space Center in Florida. Construction workers with J.P. Donovan of Rockledge, Florida, attach new heat-resistant bricks on the north side of the flame trench. The Pad B flame trench is being refurbished to support the launch of NASA’s Space Launch System rocket. The Ground Systems Development and Operations (GSDO) Program at Kennedy is helping transform the space center into a multi-user spaceport and prepare for Exploration Mission 1, deep space missions, and NASA's Journey to Mars. For more information about GSDO, visit: http://www.nasa.gov/groundsystems.

  18. Pad 39B Flame Trench Brick Work

    NASA Image and Video Library

    2016-10-26

    A construction worker with J.P. Donovan of Rockledge, Florida, checks to make sure new heat-resistant bricks attached to the north side of the flame trench are level at Launch Pad 39B at NASA’s Kennedy Space Center in Florida. The Pad B flame trench is being refurbished to support the launch of NASA’s Space Launch System rocket. The Ground Systems Development and Operations (GSDO) Program at Kennedy is helping transform the space center into a multi-user spaceport and prepare for Exploration Mission 1, deep space missions, and NASA's Journey to Mars. For more information about GSDO, visit: http://www.nasa.gov/groundsystems.

  19. Woodpecker Preventative measures at Launch Pad 39B

    NASA Technical Reports Server (NTRS)

    1995-01-01

    Technicians at Launch Pad 39B take steps to prevent further damage from woodpeckers to the Space Shuttle Discovery, set to lift off July 13 on Mission STS-70. Installing balloons with scary eyes, such as these two near the external tank, are just one of the measures being taken to keep woodpeckers away since Discovery's second rollout to Pad B. Discovery had to be rolled back once to the Vehicle Assembly Building to repair woodpecker holes made in the insulation covering the external tank.

  20. Under sleeper pads in switches & crossings

    NASA Astrophysics Data System (ADS)

    Plasek, Otto; Hruzikova, Miroslava

    2017-09-01

    Under sleeper pads (USPs) have been installed in the Czech railway lines since 2007 into two trial sections in switches and crossings and in a trial section with the aim to reduce rail pitch corrugation. The basic motivation for the construction of the trial track sections in turnouts was an evaluation of USPs’ influence on improvement of track quality as a consequence of ballast bed protection against extreme stress. The paper comprises experience of USPs installation in the Czech Republic in the two trial sections with switches and crossings built in 2007 and 2014. The paper particularly provides an information about USPs applications focusing on the track settlement received by an evaluation of data from the geodetic surveying by precise levelling. Some positive influence of under sleeper pads on the track quality is observed.

  1. Investigation of elastomeric bearing pad failures in Louisiana bridges : technical summary.

    DOT National Transportation Integrated Search

    1999-06-01

    The research was to investigate DOTD's neoprene bearing pad slippage problem in order to determine the cause of problem for existing bridges and bridge characteristics where bearing pad failure has occurred. The research also was to recommend modific...

  2. TID Test Results for 4th Generation iPad(TradeMark)

    NASA Technical Reports Server (NTRS)

    Guertin, S. M.; Allen, G. R.; McClure, S. S.; LaBel, K. A.

    2013-01-01

    TID testing of 4th generation iPads is reported. Of iPad subsystems, results indicate that the charging circuitry and display drivers fail at lowest TID levels. Details of construction are investigated for additional testing of components.

  3. DETAIL OF THE SLOPING CONCRETE PAD AT THE SOUTH SIDE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF THE SLOPING CONCRETE PAD AT THE SOUTH SIDE OF THE GUN EMPLACEMENT. NOTE ADDED BLOCK OF CAST CONCRETE AT THE LOW (RIGHT) END OF SLOPED PAD. VIEW FACING SOUTHWEST - U.S. Naval Base, Pearl Harbor, Ford Island 5-Inch Antiaircraft Battery, East Gun Emplacement, Ford Island, Pearl City, Honolulu County, HI

  4. Effective Padding of Multi-Dimensional Arrays to Avoid Cache Conflict Misses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, Changwan; Bao, Wenlei; Cohen, Albert

    Caches are used to significantly improve performance. Even with high degrees of set-associativity, the number of accessed data elements mapping to the same set in a cache can easily exceed the degree of associativity, causing conflict misses and lowered performance, even if the working set is much smaller than cache capacity. Array padding (increasing the size of array dimensions) is a well known optimization technique that can reduce conflict misses. In this paper, we develop the first algorithms for optimal padding of arrays for a set associative cache for arbitrary tile sizes, In addition, we develop the first solution tomore » padding for nested tiles and multi-level caches. The techniques are in implemented in PAdvisor tool. Experimental results with multiple benchmarks demonstrate significant performance improvement from use of PAdvisor for padding.« less

  5. Pad per day usage, urinary incontinence and urinary tract infections in nursing home residents.

    PubMed

    Omli, Ragnhild; Skotnes, Liv Heidi; Romild, Ulla; Bakke, August; Mykletun, Arnstein; Kuhry, Esther

    2010-09-01

    many elderly suffer from urinary incontinence and use absorbent pads. Pad use per day (PPD) is a frequently used measure of urinary incontinence. Nursing home residents are often dependent on help from nursing staff to change pads. This study was performed in order to determine whether PPD is a reliable method to quantify urinary incontinence in nursing home residents. Furthermore, the association between urinary tract infections (UTIs), PPD and fluid intake was studied. data were retrieved from a multicentre, prospective surveillance among nursing home residents. Data on the use of absorbent pads, fluid intake and incontinence volumes were collected during 48 h. During a 1-year follow-up period, data on UTIs were collected. in this study, 153 residents were included, of whom 118 (77%) used absorbent pads. Residents who used absorbent pads were at increased risk of developing UTIs compared to residents who did not use pads (41 vs 11%; P = 0.001). Daily fluid intake was not associated with UTIs (P = 0.46). The number of pad changes showed no correlation with the risk of developing UTIs (P = 0.62). Patients with a given PPD presented a wide range of incontinence volumes. the use of absorbent pads is associated with an increased risk of developing UTIs. PPD and daily fluid intake are not correlated with the risk of developing UTIs. PPD is an unreliable measure of urinary incontinence in nursing home residents.

  6. Metal-core pad-plane development for ACTAR TPC

    NASA Astrophysics Data System (ADS)

    Giovinazzo, J.; Pibernat, J.; Goigoux, T.; de Oliveira, R.; Grinyer, G. F.; Huss, C.; Mauss, B.; Pancin, J.; Pedroza, J. L.; Rebii, A.; Roger, T.; Rosier, P.; Saillant, F.; Wittwer, G.

    2018-06-01

    With the recent development of active targets and time projection chambers (ACTAR TPC) as detectors for fundamental nuclear physics experiments, the need arose for charge collection planes with a high density of readout channels. In order to fulfill the mechanical constraints for the ACTAR TPC device, we designed a pad-plane based on a metal-core circuit with an conceptually simple design and routing for signal readout, named FAKIR (in reference to a fakir bed of nails). A test circuit has been equipped with a micro mesh gaseous structure (micromegas) for signal amplification and a dedicated readout electronics. Test measurements have been performed with an 55Fe X-ray source giving an intrinsic energy resolution (FWHM) of 22 ± 1% at 5 . 9 keV, and with a 3-alpha source for which a resolution of about 130 ± 20 keV at 4 . 8 MeV has been estimated. The pad-plane has been mounted into a reduced size demonstrator version of the ACTAR TPC detector, in order to illustrate charged particle track reconstruction. The tests preformed with the X-ray and the 3-alpha sources shows that results obtained from pads signals are comparable to the intrinsic result from the micro-mesh signal. In addition, a simple alpha particle tracks analysis is performed to demonstrate that the pad plane allows a precise reconstruction of the direction and length of the trajectories.

  7. 14. VIEW OF MST, FACING SOUTHEAST, AND LAUNCH PAD TAKEN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. VIEW OF MST, FACING SOUTHEAST, AND LAUNCH PAD TAKEN FROM NORTHEAST PHOTO TOWER WITH WINDOW OPEN. FEATURES LEFT TO RIGHT: SOUTH TELEVISION CAMERA TOWER, SOUTHWEST PHOTO TOWER, LAUNCHER, UMBILICAL MAST, MST, AND OXIDIZER APRON. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  8. The Neglected "R": Improving Writing Instruction through iPad Apps

    ERIC Educational Resources Information Center

    Sessions, Laird; Kang, Mi Ok; Womack, Sue

    2016-01-01

    In this study the authors investigated the effects of integrating iPad applications into writing instruction for fifth grade students. By comparing the writing of students taught with paper and pencil methods with that of students utilizing the iPad writing applications, two research questions guided the study: (1) Are there differences in student…

  9. Design and performance considerations of evaporative-pad, waste-heat greenhouses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olszewski, M.

    1978-01-01

    Rising fuel costs and limited fuel availability have forced greenhouse operators to seek alternative means of heating their greenhouses in an effort to reduce production costs and conserve energy. One such alternative uses power plant reject heat, which is contained in the condenser cooling water, and a bank of evaporative pads to provide winter heating. The design technique used to size the evaporative pad system to meet both summer cooling and winter heating demands is described. Additionally, a computational scheme that simulates the system performance is presented. This analytical model is used to determine the greenhouse operating conditions that maintainmore » the vegetation in its thermal comfort zone. The evaporative pad model uses the Merkel total heat approximation and an experimentally derived transfer coefficient. Energy balance considerations on the vegetation provide a means of viewing optimal vegetation growth in terms of greenhouse environmental factors. In general, the results indicate that the vegetation can be maintained within its thermal comfort zone if sufficient warm water is available to the pads and the air stream flow is properly adjusted.« less

  10. Operating characteristics of a cantilever-mounted resilient-pad gas-lubricated thrust bearing

    NASA Technical Reports Server (NTRS)

    Nemeth, Z. N.

    1979-01-01

    A resilient-pad gas thrust bearing consisting of pads mounted on cantilever beams was tested to determine its operating characteristic. The bearing was run at a thrust load of 74 newtons to a speed of 17000 rpm. The pad film thickness and bearing friction torque were measured and compared with theory. The measured film thickness was less than that predicted by theory. The bearing friction torque was greater than that predicted by theory.

  11. Teacher Perceptions and Experiences Using the Apple iPad as an Instructional Tool

    ERIC Educational Resources Information Center

    Perez, Carlos Raul, Jr.

    2017-01-01

    The number of iPads in classrooms throughout the country is growing at a staggering rate. Educators and school districts are implementing iPad initiatives to enhance instruction. The purpose of this study was to examine high school teachers' experiences and perceptions after using the Apple iPad as an instructional tool in the classroom. An…

  12. Use of Doceri Software for iPad in Online Delivery of Chemistry Content

    ERIC Educational Resources Information Center

    Silverberg, Lee J.; Tierney, John; Bodek, Matthew J.

    2014-01-01

    Doceri software for iPad is useful for both synchronous online and asynchronous online delivery of chemistry course content. Using the Doceri wireless connection between the iPad and a personal computer that is running Adobe Connect, online synchronous instruction can be accomplished in which drawings can be completed by hand on the iPad. For…

  13. Neoprene pads for capping concrete cylinders.

    DOT National Transportation Integrated Search

    1979-01-01

    The possibility of using neoprene pads as an alternate to sulfur mortar for capping concrete specimens subjected to compression tests was investigated. In preliminary tests to determine the feasibility of the investigation, two batches of concrete we...

  14. Another Perspective: The iPad Is a REAL Musical Instrument

    ERIC Educational Resources Information Center

    Williams, David A.

    2014-01-01

    This article looks at the iPad's role as a musical instrument through the lens of a live performance ensemble that performs primarily on iPads. It also offers an overview of a pedagogical model used by this ensemble, which emphasizes musician autonomy in small groups, where music is learned primarily through aural means and concerts are…

  15. The Development of Advanced Learner Oral Proficiency Using iPads

    ERIC Educational Resources Information Center

    Lys, Franziska

    2013-01-01

    In this study, I investigate the use and integration of iPads in an advanced German conversation class. In particular, I am interested in analyzing how students learn with this new technology and how it affects the development of their oral proficiency level. Overall, my results suggest that iPads are well suited to practice listening and speaking…

  16. Engaging Organic Chemistry Students Using ChemDraw for iPad

    ERIC Educational Resources Information Center

    Morsch, Layne A.; Lewis, Michael

    2015-01-01

    Drawing structures, mechanisms, and syntheses is a vital part of success in organic chemistry courses. ChemDraw for iPad has been used to increase classroom experiences in the preparation of high quality chemical drawings. The embedded Flick-to-Share allows for simple, real-time exchange of ChemDraw documents. ChemDraw for iPad also allows…

  17. Ice hockey shoulder pad design and the effect on head response during shoulder-to-head impacts.

    PubMed

    Richards, Darrin; Ivarsson, B Johan; Scher, Irving; Hoover, Ryan; Rodowicz, Kathleen; Cripton, Peter

    2016-11-01

    Ice hockey body checks involving direct shoulder-to-head contact frequently result in head injury. In the current study, we examined the effect of shoulder pad style on the likelihood of head injury from a shoulder-to-head check. Shoulder-to-head body checks were simulated by swinging a modified Hybrid-III anthropomorphic test device (ATD) with and without shoulder pads into a stationary Hybrid-III ATD at 21 km/h. Tests were conducted with three different styles of shoulder pads (traditional, integrated and tethered) and without shoulder pads for the purpose of control. Head response kinematics for the stationary ATD were measured. Compared to the case of no shoulder pads, the three different pad styles significantly (p < 0.05) reduced peak resultant linear head accelerations of the stationary ATD by 35-56%. The integrated shoulder pads reduced linear head accelerations by an additional 18-21% beyond the other two styles of shoulder pads. The data presented here suggest that shoulder pads can be designed to help protect the head of the struck player in a shoulder-to-head check.

  18. ATLANTIS ROLLS OUT TO PAD 39A FOLLOWING HURRICANE FRAN THREAT

    NASA Technical Reports Server (NTRS)

    1996-01-01

    A view from the flame trench looking up shows the Space Shuttle Atlantis, mounted on the Mobile Launcher Platform and Crawler- Transporter, as it arrives atop the hardstand at Launch Pad 39A. After the Shuttle and launch stand are in position, the crawler will be pulled back. This is the third time Atlantis has completed the journey to Launch Pad 39A in the STS-79 mission flow. The Shuttle was rolled back from the pad in July due to the threat from Hurricane Bertha, then rolled back again earlier this week because of Hurricane Fran. The targeted launch date for Atlantis on Mission STS-79 -- the fourth docking between the U.S. Shuttle and Russian Space Station Mir -- is now Sept. 16 at 4:54 a.m. EDT. The three rollout dates for Atlantis to Pad 39A are: July 1, Aug. 20 and Sept. 5.

  19. Pad 39B Flame Trench Brick Work

    NASA Image and Video Library

    2016-10-26

    Progress continues on the new flame trench at Launch Pad 39B at NASA's Kennedy Space Center in Florida. Construction workers with J.P. Donovan of Rockledge, Florida, are on an elevated work stand to install new heat-resistant bricks on the north side of the flame trench. The Pad B flame trench is being refurbished to support the launch of NASA’s Space Launch System rocket. The Ground Systems Development and Operations (GSDO) Program at Kennedy is helping transform the space center into a multi-user spaceport and prepare for Exploration Mission 1, deep space missions, and NASA's Journey to Mars. For more information about GSDO, visit: http://www.nasa.gov/groundsystems.

  20. Pad 39B Flame Trench Brick Work

    NASA Image and Video Library

    2016-10-26

    Construction workers with J.P. Donovan of Rockledge, Florida, cut new heat-resistant bricks to size for the concrete walls of the flame trench at Launch Pad 39B at NASA’s Kennedy Space Center in Florida. New heat-resistant bricks are being attached with epoxy mortar to the flame trench walls. The Pad B flame trench is being refurbished to support the launch of NASA’s Space Launch System rocket. The Ground Systems Development and Operations (GSDO) Program at Kennedy is helping transform the space center into a multi-user spaceport and prepare for Exploration Mission 1, deep space missions, and NASA's Journey to Mars. For more information about GSDO, visit: http://www.nasa.gov/groundsystems.

  1. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    Mist or vapor is visible as a Praxair truck slowly transfers its load of liquid oxygen, or LO2, into a giant storage sphere at the northwest corner of Launch Pad 39B at NASA's Kennedy Space Center in Florida. The sphere will gradually be chilled down from normal temperature to about negative 298 degrees Fahrenheit, during the first major integrated operation to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  2. [Absorbable shanching satin rb-bFGF prepreg sheet and expansion hemostatic sponge together to cure epistaxis with blood disease].

    PubMed

    Liu, Hua; Gao, Zhanmei; Song, Yang; Lu, Mancun

    2014-01-01

    This study investigated the effects and Numerical Rating Pain Scale (NRS) of using absorbable shanching satin rb-bFGF prepreg sheet and expansion hemostatic sponge together nasal packing in the control of epistaxis with blood disease, and compared it with traditional vaseline gauze. Ninety-six blood disease patient with epistaxis were enrolled between January 2009 and February 2011, they were divided into two groups at random, and differently treated with absorbable shanching satin rb-bFGF prepreg sheet and the vaseline gauze nasal packing for haemostasis. Then haemostasis efficacy,the hemorrhage rate after nasal packing removed and host response, such as nasal pain and headache, which evaluated pain degrees against NRS, were all observed. There was no significant difference between the two groups of the haemostatic effect. But the hemorrhage rate of treatment group was obviously lower than that of the control group after paching,in addition, host responses, such as nasal pain and headache, remarkably better than the control group, the difference had statistical significance. It is indicate that absorbable shanching satin rb-bFGF prepreg sheet presents reliable hemostasis effect, good biocompatibility and compliance; the pain and headache caused by packing are superior to vaseline gauze. Moreover, this method avoids the direct touch of vaseline gauze with nasal mucosal wound, and reduce hemorrhage after packing. Absorbable shanching satin rb-bFGF prepreg sheet and expansion hemostatic sponge together is better to select the nasal packing material for blood disease patient with epistaxis.

  3. Removal of mouse ovary fat pad affects sex hormones, folliculogenesis and fertility.

    PubMed

    Wang, Hong-Hui; Cui, Qian; Zhang, Teng; Guo, Lei; Dong, Ming-Zhe; Hou, Yi; Wang, Zhen-Bo; Shen, Wei; Ma, Jun-Yu; Sun, Qing-Yuan

    2017-02-01

    As a fat storage organ, adipose tissue is distributed widely all over the body and is important for energy supply, body temperature maintenance, organ protection, immune regulation and so on. In humans, both underweight and overweight women find it hard to become pregnant, which suggests that appropriate fat storage can guarantee the female reproductive capacity. In fact, a large mass of adipose tissue distributes around the reproductive system both in the male and female. However, the functions of ovary fat pad (the nearest adipose tissue to ovary) are not known. In our study, we found that the ovary fat pad-removed female mice showed decreased fertility and less ovulated mature eggs. We further identified that only a small proportion of follicles developed to antral follicle, and many follicles were blocked at the secondary follicle stage. The overall secretion levels of estrogen and FSH were lower in the whole estrus cycle (especially at proestrus); however, the LH level was higher in ovary fat pad-removed mice than that in control groups. Moreover, the estrus cycle of ovary fat pad-removed mice showed significant disorder. Besides, the expression of FSH receptor decreased, but the LH receptor increased in ovary fat pad-removed mice. These results suggest that ovary fat pad is important for mouse reproduction. © 2017 Society for Endocrinology.

  4. Ct Anatomy of Buccal Fat Pad and its Role in Volumetric Alterations of Face

    NASA Astrophysics Data System (ADS)

    Guryanov, R. A.; Guryanov, A. S.

    2015-05-01

    The aim of our study is the revision of the anatomy of buccal fat pad and its role in a volumetric pattern of face. Bichat fat pad is a fatty anatomical structure with body and numerous process enclosed between the bony and muscular structures in temporal, pterygopalatine fossae and extents to the cheek area. Nevertheless, the opinion about its structure and role in forming of volume pattern of face sometimes could be controversial. The Bichat fat pad consists on predominately hormone insensitive fat tissue with underdeveloped stroma, this leads to the stability of the fat pad volume and lesser radiodensity in contrast to the subcutaneous fat. Moreover, the buccal fat pad is delimited from the subcutaneous fat of cheek area by the strong capsule. This feature allows us to use CT to divide the Bichat fat pad from the surrounding tissues. The thorough embryological data provide the distinction of Bichat fat pad from the subcutaneous fat of cheek area even at the stage of development. On the other hand, the border between the masticatory muscles and the processes of the fat pad is not evident and resembles cellular spaces in the other anatomical areas. To elicit the role of the buccal fat pad in volume pattern of face and its function we have performed the several experiments, analyzed the postoperative results after Bichat fat pad resection using surface scanner and CT data. At first, we have performed the gravity test: the patient's face photogrammetry scanning in horizontal and vertical position of head and it revealed the excess of volume in temporal area in horizontal position. To exclude mechanism of overflowing of the skin and subcutaneous fat over the zygomatic arch we have placed the markers on the skin surface at the different areas of face including the projection of ligaments and found out that the migration of soft tissue over the zygomatic arch is about 3-5 mm and almost the same in temporal area. However, the acquired result was unsatisfying because

  5. Effect of metatarsal pad placement on plantar pressure in people with diabetes mellitus and peripheral neuropathy.

    PubMed

    Hastings, Mary K; Mueller, Michael J; Pilgram, Thomas K; Lott, Donovan J; Commean, Paul K; Johnson, Jeffrey E

    2007-01-01

    Standard prevention and treatment strategies to decrease peak plantar pressure include a total contact insert with a metatarsal pad, but no clear guidelines exist to determine optimal placement of the pad with respect to the metatarsal head. The purpose of this study was to determine the effect of metatarsal pad location on peak plantar pressure in subjects with diabetes mellitus and peripheral neuropathy. Twenty subjects with diabetes mellitus, peripheral neuropathy, and a history of forefoot plantar ulcers were studied (12 men and eight women, mean age=57+/-9 years). CT determined the position of the metatarsal pad relative to metatarsal head and peak plantar pressures were measured on subjects in three footwear conditions: extra-depth shoes and a 1) total contact insert, 2) total contact insert and a proximal metatarsal pad, and 3) total contact insert and a distal metatarsal pad. The change in peak plantar pressure between shoe conditions was plotted and compared to metatarsal pad position relative to the second metatarsal head. Compared to the total contact insert, all metatarsal pad placements between 6.1 mm to 10.6 mm proximal to the metatarsal head line resulted in a pressure reduction (average reduction=32+/-16%). Metatarsal pad placements between 1.8 mm distal and 6.1 mm proximal and between 10.6 mm proximal and 16.8 mm proximal to the metatarsal head line resulted in variable peak plantar pressure reduction (average reduction=16+/-21%). Peak plantar pressure increased when the metatarsal pad was located more than 1.8 mm distal to the metatarsal head line. Consistent peak plantar pressure reduction occurred when the metatarsal pad in this study was located between 6 to 11 mm proximal to the metatarsal head line. Pressure reduction lessened as the metatarsal pad moved outside of this range and actually increased if the pad was located too distal of this range. Computational models are needed to help predict optimal location of metatarsal pad with a variety

  6. View of the Endeavour moving towards it launch pad

    NASA Image and Video Library

    1996-06-06

    STS077-S-044 (16 April 1996) --- The Space Shuttle Endeavour atop the Mobile Launcher Platform and Crawler-Transporter (MLP/CT) slowly lumbers past a tree alongside the crawlerway, at the Kennedy Space Center (KSC). The journey from the Vehicle Assembly Building (VAB) to Launch Pad 39B will take about five to six hours to complete. Once hard down at the pad, preparations will continue to ready Endeavour for its upcoming spaceflight on STS-77.

  7. Method for Producing Launch/Landing Pads and Structures Project

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P. (Compiler)

    2015-01-01

    Current plans for deep space exploration include building landing-launch pads capable of withstanding the rocket blast of much larger spacecraft that that of the Apollo days. The proposed concept will develop lightweight launch and landing pad materials from in-situ materials, utilizing regolith to produce controllable porous cast metallic foam brickstiles shapes. These shapes can be utilized to lay a landing launch platform, as a construction material or as more complex parts of mechanical assemblies.

  8. ClimatePad: Enabling public exploration of climate data

    NASA Astrophysics Data System (ADS)

    Walsh, J. E.; Chapman, W. L.

    2012-12-01

    Informal learners interested in climate issues can find a wealth of information in the print and online media related to climate and climate change. Throughout these resources, the equal use of generic terms like 'global warming' and 'climate change' suggest a level of nuance in the science that is not easy to convey in this conventional media. Perhaps more than any other discipline, climate literacy has the most potential to be enhanced via the process of cognitive construction and reconstruction, rather than simple transmission of knowledge. Constructionism suggests that meaningful learning happens most effectively if the learner is actively engaged in constructing a product in the real world rather than absorbing information passively. Recent technological innovations have introduced mobile computing devices with sufficient power to do serious data analysis. The potential of these devices to augment climate literacy by turning citizens into scientists has yet to be exploited. We introduce ClimatePad, an iPad application that permits students and public to actively browse climate datasets, construct trends, plot time series, create composite differences and view animations of real-world climate data. Interactions with the ClimatePad permits varying the starting and ending dates of trends and differences. Climate analysis maps and animations can be customized with different color palettes, enticing the user to delve into and absorb the subtleties of the regional and temporal variations of the recent climate record. Finally, user-generated climate visualizations created with ClimatePad can be emailed to friends and shared via Facebook, entraining even more active learners.

  9. Effects of contamination by either blood or a hemostatic agent on the shear bond strength of orthodontic buttons

    PubMed Central

    Alkis, Huseyin; Turkkahraman, Hakan

    2013-01-01

    Objective To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. Methods We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. Results ANOVA indicated a significant difference between groups (p < 0.001). The highest SBS values were measured in group III (10.73 ± 0.96 MPa). The SBS values for teeth in groups I and II were significantly lower than that of group III (p < 0.001). The lowest SBS values were observed in group I teeth (4.17 ± 1.11 MPa) (p < 0.001). Conclusions Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth. PMID:23671834

  10. Evaluation of the hemostatic and histopathological effects of Ankaferd Blood Stopper in experimental liver injury in rats.

    PubMed

    Satar, Nihal Y Gul; Akkoc, Ahmet; Oktay, Ayberk; Topal, Ayse; Inan, Kivanc

    2013-07-01

    We studied the hemostatic and histopathological effects, and intra-abdominal adhesion scores of a new hemostatic agent, Ankaferd Blood Stopper (ABS), in an experimental liver injury model and compared it with regenerated oxidized cellulose. Thirty-six rats were randomly assigned to ABS, oxidized cellulose (Surgicel), and control groups (n=12, each). A wedge resection was performed on the left medial lobe of the liver. In the ABS group the liver surface was sprayed with ABS, whereas in the Surgicel group the liver was covered with double-layered oxidized cellulose. In the control group, saline solution was sprayed on the cut surface. The mean bleeding time was shorter in the ABS (23.08±6.99s) and Surgicel groups (47.91±8.21s) than in the control group (223.42±57.83s). No significant difference was found in the ABS and Surgicel groups in terms of preoperative and postoperative hematocrit (hct) values (P>0.05). Whereas there was no significant difference on day 7 (P>0.05), total adhesion score of ABS group was lower than both Surgicel (P<0.05) and control groups (P<0.01) on day 14. Liver sections from ABS group displayed more favorable histopathological changes when compared with Surgicel group on day 7 and day 14. All livers in the ABS group completed their regeneration process with minimal signs of inflammation. Our findings suggest that ABS is more effective than Surgicel and control groups in achieving hemostasis and in reducing blood loss. Apart from this, ABS causes more encouraging histopathological changes and better intra-abdominal adhesion scores in rat experimental liver trauma model.

  11. Direct application of Padé approximant for solving nonlinear differential equations.

    PubMed

    Vazquez-Leal, Hector; Benhammouda, Brahim; Filobello-Nino, Uriel; Sarmiento-Reyes, Arturo; Jimenez-Fernandez, Victor Manuel; Garcia-Gervacio, Jose Luis; Huerta-Chua, Jesus; Morales-Mendoza, Luis Javier; Gonzalez-Lee, Mario

    2014-01-01

    This work presents a direct procedure to apply Padé method to find approximate solutions for nonlinear differential equations. Moreover, we present some cases study showing the strength of the method to generate highly accurate rational approximate solutions compared to other semi-analytical methods. The type of tested nonlinear equations are: a highly nonlinear boundary value problem, a differential-algebraic oscillator problem, and an asymptotic problem. The high accurate handy approximations obtained by the direct application of Padé method shows the high potential if the proposed scheme to approximate a wide variety of problems. What is more, the direct application of the Padé approximant aids to avoid the previous application of an approximative method like Taylor series method, homotopy perturbation method, Adomian Decomposition method, homotopy analysis method, variational iteration method, among others, as tools to obtain a power series solutions to post-treat with the Padé approximant. 34L30.

  12. Experimental Research and Analysis of Rotordynamic Characteristics for a New Kind of Tilting-pad Gas Seal

    NASA Astrophysics Data System (ADS)

    Cao, Hao; Cao, Xiaoyu; Chen, Fei; Li, Ming; Zhang, Bolin; Wei, Jilong

    2017-12-01

    This paper presents a new kind of tilting-pad gas seal. This design is introduced to reduce the tangential seal force and to improve the stability of rotor system finally. A seal test rig is set up. The paper compares the leakage between tilting-pad seal and fixed pad seal. The result shows that the leakage ratio of the tilting-pad seal is close to the leakage ratio of the fixed pad seal. The work done by seal force on the cylinder system is calculated as an index of comparison between these two seals. Result shows that the work done by the fixed pad seal is greater than the work done by the tilting-pad seal. Moreover, system damping factor is used to compare the stabilities of these two seals. The impact tests on the cylinder system are done under different conditions. The system damping factors are calculated from the damped waves of system vibration. Test results show that the damping factor of the tilting pad seal is higher than that of the fixed pad seal in both the vertical and the horizontal directions.

  13. Physicochemical characterization of cactus pads from Opuntia dillenii and Opuntia ficus indica.

    PubMed

    Méndez, Lorena Pérez; Flores, Fidel Tejera; Martín, Jacinto Darias; Rodríguez Rodríguez, Elena M; Díaz Romero, Carlos

    2015-12-01

    Physicochemical characteristics (weight, length, width, thickness, moisture, Brix degree, total fiber, protein, ash, pH, acidity, ascorbic acid, total phenolic compounds, P, Na, K, Ca, Mg, Fe, Cu, Zn, Mn and Cr) were determined in cactus pads from Opuntia dillenii and Opuntia ficus indica. The physicochemical characteristics of both species were clearly different. There were important differences between the orange and green fruit pulp of O. ficus indica; the cactus pads of O. dillenii could be differentiated according to the region (North and South). Consumption of cactus pads contributes to the intake of dietary fiber, total phenolic compounds, K, Mg, Mn and Cr. Applying factor and/or discriminant analysis, the cactus pad samples were clearly differentiated according to the species, the fruit pulp color and production region. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. A Scott bench with ergonomic thorax stabilisation pad improves body posture during preacher arm curl exercise.

    PubMed

    Biscarini, Andrea; Benvenuti, Paolo; Busti, Daniele; Zanuso, Silvano

    2016-05-01

    We assessed whether the use of an ergonomic thorax stabilisation pad, during the preacher arm curl exercise, could significantly reduce the excessive shoulder protraction and thoracic kyphosis induced by the standard flat pad built into the existing preacher arm curl equipment. A 3D motion capture system and inclinometers were used to measure shoulder protraction and thoracic kyphosis in 15 subjects performing preacher arm curl with a plate-loaded machine provided with the standard flat pad. The same measures were repeated after replacing the flat pad with a new ergonomic pad, specifically designed to accommodate the thorax profile and improve body posture. Pad replacement significantly (p < 0.001) reduced shoulder protraction (from [Formula: see text] to [Formula: see text]) and thoracic kyphosis (from [Formula: see text] to [Formula: see text]), enabling postural and functional improvements within the entire spine, shoulder girdle and rib cage. The ergonomic pad may potentially allow a more effective training, prevent musculoskeletal discomfort and reduce the risk of injury. Practitioner summary: We have designed an ergonomic thorax stabilisation pad for the preacher arm curl exercise. The new ergonomic pad improves the poor posture conditions induced by the standard flat pad and may potentially allow a more effective training, prevent musculoskeletal discomfort, improve the breathing function and reduce the risk of injury.

  15. Measuring contact area in a sliding human finger-pad contact.

    PubMed

    Liu, X; Carré, M J; Zhang, Q; Lu, Z; Matcher, S J; Lewis, R

    2018-02-01

    The work outlined in this paper was aimed at achieving further understanding of skin frictional behaviour by investigating the contact area between human finger-pads and flat surfaces. Both the static and the dynamic contact areas (in macro- and micro-scales) were measured using various techniques, including ink printing, optical coherence tomography (OCT) and Digital Image Correlation (DIC). In the studies of the static measurements using ink printing, the experimental results showed that the apparent and the real contact area increased with load following a piecewise linear correlation function for a finger-pad in contact with paper sheets. Comparisons indicated that the OCT method is a reliable and effective method to investigate the real contact area of a finger-pad and allow micro-scale analysis. The apparent contact area (from the DIC measurements) was found to reduce with time in the transition from the static phase to the dynamic phase while the real area of contact (from OCT) increased. The results from this study enable the interaction between finger-pads and contact object surface to be better analysed, and hence improve the understanding of skin friction. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Launch Pad Activities

    NASA Image and Video Library

    1959-09-08

    Big Joe Capsule Launch Pad Activities: This film covers both the Big Joe and a Little Joe Project Mercury flight test with a research and development version of the Mercury capsule. Big Joe was an Atlas missile that successfully launched a boilerplate model of the Mercury capsule on September 9, 1959. The lower half of the capsule was created at NASA Lewis. The scenes include coverage of the assembly and erection of the boosters, delivery of the capsules, mating of the capsules to the boosters, prelaunch views of the capsule and boosters on launchers, mission control, the launches, and recovery.

  17. School Administrators' Use of iPads: Impact of Training and Attitudes toward School Use

    ERIC Educational Resources Information Center

    Dogan, Bulent; Almus, Kadir

    2014-01-01

    As Apple iPads are increasingly being adopted in schools for educational purposes, school administrators are seen as the key facilitators in the implementation of this new technology. This survey-based quantitative study investigated the impact of receiving iPad training on school administrators' attitudes towards iPad use in their professional…

  18. Water Deluge Test at Pad 39B

    NASA Image and Video Library

    2018-05-24

    About 450,000 gallons of water flow at high speed from a holding tank through new and modified piping and valves, the flame trench, flame deflector nozzles and mobile launcher interface risers during a wet flow test on May 24, 2018, at Launch Pad 39B at NASA's Kennedy Space Center in Florida. At peak flow, the water reached about 100 feet in the air above the pad surface. The test was performed by Exploration Ground Systems to confirm the performance of the Ignition Overpressure/Sound Suppression system. During launch of NASA's Space Launch System rocket and Orion spacecraft, the high-speed water flow will help protect the vehicle from the extreme acoustic and temperature environment during ignition and liftoff.

  19. Cryo Tank Fill at Pad 39B

    NASA Image and Video Library

    2017-09-26

    A large plume of mist or vapor is visible as a Praxair truck slowly transfers its load of liquid oxygen, or LO2, into a giant storage sphere at the northwest corner of Launch Pad 39B at NASA's Kennedy Space Center in Florida. The sphere will gradually be chilled down from normal temperature to about negative 298 degrees Fahrenheit, during the first major integrated operation to prepare for the launch of the agency's Orion spacecraft atop the Space Launch System (SLS) rocket. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to pad B to support the launch of the SLS and Orion spacecraft for Exploration Mission-1, deep space missions and NASA’s journey to Mars.

  20. Mobile Tech and the Librarian: The iTest iPad Project

    PubMed Central

    Hamasu, Claire; Bramble, John

    2015-01-01

    A 2012 project provided forty-eight health sciences librarians from primarily hospital and academic health sciences libraries with an Apple iPad2 along with training and support on its use. Project objectives were to determine how participants would adopt the iPad into their daily operations and what form of leadership role they would play while participating in the project. By project's end eighty-nine percent indicated they would continue using the iPad primarily as a productivity tool and to provide point of need services. Project data indicated that librarians assumed a leadership role promoting the use of mobile technology and the applications available. PMID:26997921

  1. Mobile Tech and the Librarian: The iTest iPad Project.

    PubMed

    Hamasu, Claire; Bramble, John

    A 2012 project provided forty-eight health sciences librarians from primarily hospital and academic health sciences libraries with an Apple iPad2 along with training and support on its use. Project objectives were to determine how participants would adopt the iPad into their daily operations and what form of leadership role they would play while participating in the project. By project's end eighty-nine percent indicated they would continue using the iPad primarily as a productivity tool and to provide point of need services. Project data indicated that librarians assumed a leadership role promoting the use of mobile technology and the applications available.

  2. ATLANTIS ROLLS OUT TO PAD 39A FOLLOWING HURRICANE FRAN THREAT

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The Space Shuttle Atlantis completes the trip to Launch Pad 39A from the Vehicle Assembly Building for the third time in the STS- 79 mission flow. The Shuttle was rolled back from the pad in July due to the threat from Hurricane Bertha, then rolled back again earlier this week because of Hurricane Fran. The targeted launch date for Atlantis on Mission STS-79 -- the fourth docking between the U.S. Shuttle and Russian Space Station Mir -- is now Sept. 16 at 4:54 a.m. EDT. The three rollout dates for Atlantis to Pad 39A are: July 1, Aug. 20 and Sept. 5.

  3. 44. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM SOUTHWEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM SOUTHWEST. DOORS FOR THE UMBILICAL MAST TRENCH RAISED FOR MAINTENANCE POSITION OF 10 DEGREES. LAUNCHER IS RIGHT OF MAST; RAILS PARALLEL TO MAST. CONTROL PANELS LEFT TO RIGHT: ELECTRICAL PANEL, COMMUNICATIONS PANEL, AND MAST CONTROL PANEL. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  4. Assessment and Evaluation of Anatomic Variations of Retromolar Pad: A Cross Sectional Study

    PubMed Central

    Deep, Anchal; Siwach, Amit; Singh, Manas; Bhargava, Akshay; Siwach, Reenu

    2016-01-01

    Introduction The retromolar pad also called piriformis papilla is a mucosal elevation located in the retromolar area covering the retromolar triangle. After molar loss, the bony alveolar process and surrounding soft periodontal tissue remodel, mainly resorb and blend with retromolar pad. It is a key intraoral landmark in prosthodontics. Aim The aim of this in-vitro study was to analyze the various anatomical shapes and sizes of retromolar pad in 150 completely edentulous patients between 55 to 70 years of age group. Materials and Methods The study was conducted on 150 completely edentulous patients. The shapes of retromolar pad on the left and right side were seen and divided into pear, triangular and round shape. The comparison of the mean longitudinal diameter and transverse diameter on the right and left sides was done. The data was evaluated statistically. The chi-square test was used for the comparison between the proportions with the help of standard deviation, t-test was used for comparison between the left and the right side and ANOVA test was used for comparison between the various shapes of the retromolar pads. Results The result showed that there was statistically significant difference among different shapes of retromolar pad and there was significant difference in mean transverse and longitudinal diameter on right and left side, the mean value of the longitudinal diameter on left and right side was 8.81 and 8.69 whereas the mean value of the transverse diameter on left and right side was 6.79 and 6.82 respectively and p-value obtained for both was 0.550 and 0.814 respectively. Conclusion The study conclude that there are three different shapes of retromolar pad among which pear and triangular shaped retomolar pad provides more stability in lower denture because of increase surface area. PMID:27437350

  5. Digital representation of oil and natural gas well pad scars in southwest Wyoming

    USGS Publications Warehouse

    Garman, Steven L.; McBeth, Jamie L.

    2014-01-01

    The recent proliferation of oil and natural gas energy development in southwest Wyoming has stimulated the need to understand wildlife responses to this development. Central to many wildlife assessments is the use of geospatial methods that rely on digital representation of energy infrastructure. Surface disturbance of the well pad scars associated with oil and natural gas extraction has been an important but unavailable infrastructure layer. To provide a digital baseline of this surface disturbance, we extracted visible oil and gas well pad scars from 1-meter National Agriculture Imagery Program imagery (NAIP) acquired in 2009 for a 7.7 million-hectare region of southwest Wyoming. Scars include the pad area where wellheads, pumps, and storage facilities reside, and the surrounding area that was scraped and denuded of vegetation during the establishment of the pad. Scars containing tanks, compressors, and the storage of oil and gas related equipment, and produced-water ponds were also collected on occasion. Our extraction method was a two-step process starting with automated extraction followed by manual inspection and clean up. We used available well-point information to guide manual clean up and to derive estimates of year of origin and duration of activity on a pad scar. We also derived estimates of the proportion of non-vegetated area on a scar using a Normalized Difference Vegetation Index derived using 1-meter NAIP imagery. We extracted 16,973 pad scars of which 15,318 were oil and gas well pads. Digital representation of pad scars along with time-stamps of activity and estimates of non-vegetated area provides important baseline (circa 2009) data for assessments of wildlife responses, land-use trends, and disturbance-mediated pattern assessments.

  6. An approach to evaluate capacitance, capacitive reactance and resistance of pivoted pads of a thrust bearing

    NASA Astrophysics Data System (ADS)

    Prashad, Har

    1992-07-01

    A theoretical approach is developed for determining the capacitance and active resistance between the interacting surfaces of pivoted pads and thrust collar, under different conditions of operation. It is shown that resistance and capacitive reactance of a thrust bearing decrease with the number of pads times the values of these parameters for an individual pad, and that capacitance increases with the number of pads times the capacitance of an individual pad. The analysis presented has a potential to diagnose the behavior of pivoted pad thrust bearings with the angle of tilt and the ratio of film thickness at the leading to trailing edge, by determining the variation of capacitance, resistance, and capacitive reactance.

  7. Older adults' perceptions of using iPads for improving fruit and vegetable intake: an exploratory study.

    PubMed

    Watkins, Ivan; Xie, Bo

    2015-01-01

    Fruit and vegetable (FV) consumption can improve older adults' health outcomes, but conventional interventions can be resource demanding and make it difficult to provide just-in-time intervention content. iPad-based interventions may help overcome these limitations, but little is known about how older adults might perceive and use iPads for FV consumption. To address this gap in the literature, we conducted a qualitative study to explore older adults' perceptions and use of iPads for improving FV consumption between February and August of 2012. Five focus group sessions each lasting 120 min were conducted with 22 older adult participants. During each session, participants received guided exposure and instruction on iPad use and then explored three iPad applications targeting FV consumption (MyFood, FiveADay Lite, and Whole Foods Market Recipes). Detailed notes from focus group interviews were analyzed with a grounded theory approach that applied a constant comparative method to enable themes to emerge from the data. Three themes were identified from the data regarding participants' baseline perceptions of iPads. These included (a) limited knowledge on iPad's functions, (b) iPads were intended for younger users, and (c) iPads were too expensive. Themes identified regarding participants' perceptions of iPads after guided exposure included (a) the touchscreen was easier to use than a computer mouse, (b) tapping the interface required practice, (c) portability was an asset in conjunction with functionality, (d) portability and functionality supported personal interests, (e) the difficulty of learning an iPad's functions varied, and (f) practice and instruction helped overcome fear of the iPad. Finally, participants recommended iPad app features that could help them overcome barriers to their FV intake. These included (a) locating inexpensive FV from nearby sources, (b) providing tailored food and recipe suggestions, and (c) tracking and communicating FV intake with a

  8. Shock absorbency of factors in the shoe/heel interaction--with special focus on role of the heel pad.

    PubMed

    Jørgensen, U; Bojsen-Møller, F

    1989-06-01

    The heel pad acts as a shock absorber in walking and in heel-strike running. In some patients, a reduction of its shock-absorbing capacity has been connected to the development of overuse injuries. In this article, the shock absorption of the heel pad as well as external shock absorbers are studied. Individual variation and the effect of trauma and confinement on the heel pad were specifically investigated. Drop tests, imitating heel impacts, were performed on a force plate. The test specimens were cadaver heel pads (n = 10); the shoe sole component consisted of ethyl vinyl acetate (EVA) foam and Sorbothane inserts. The shock absorption was significantly greater in the heel pad than in the external shock absorbers. The mean heel pad shock absorption was 1.1 times for EVA foam and 2.1 times for Sorbothane. The shock absorption varied by as much as 100% between heel pads. Trauma caused a decrease in the heel pad shock absorbency (24%), whereas heel pad confinement increased the shock absorbency (49% in traumatized heel pads and 29.5% in nontraumatized heel pads). These findings provide a biomechanical rationale for the clinical observations of a correlation between heel pad shock absorbency loss and heel strike-dependent overuse injuries. To increase shock absorbency, confinement of the heel pad should be attempted in vivo.

  9. Focused Molding Using Adhesive Pads in Mehta Casting for Early-Onset Scoliosis.

    PubMed

    Abraham, Roby; Sponseller, Paul D

    2014-11-01

    Prospective clinical series. To determine the effect of adhesive pads placed over the apex of scoliosis curves on curve correction 1) after the first cast and 2) after the final cast. Early-onset scoliosis is often effectively managed by serial casting. Properly localizing the apex of the molds with the cast in place is challenging. The authors explored the effectiveness of a novel technique: incorporation of adhesive pads placed over the major curve apex before Mehta casting. The 27 patients who received body casts (2000-2013) were divided into 2 groups: those without and with apical adhesive pads (5-6 layers of pads placed on the major curve's apex during casting): non-pad (NP) group (n = 12) and pad (P) group (n = 15), respectively. Groups were compared regarding the percentage of Cobb angle change from the first cast and curve correction to a Cobb angle of <25° with Student t and chi-square tests (significance was p < .05). The mean percentage of major first-cast curve correction was 39% ± 18% and 56% ± 17% in the NP and P groups, respectively. Of the 26 patients out of a cast, 11 (42%) had a Cobb angle of <25°: 3 (25%) and 8 (57%) in the NP and P groups, respectively. The mean differences between the 2 groups in percentage of major curve correction and this Cobb angle correction were significant: p = .023 and .005, respectively. Adhesive pads placed over major curve(s) during Mehta casting were effective in increasing the amount of major curve correction from the first cast for idiopathic early-onset scoliosis and in decreasing curves to <25° at final follow-up. Copyright © 2014 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  10. The use of platelet-rich fibrin as a hemostatic material in oral soft tissues.

    PubMed

    de Almeida Barros Mourão, Carlos Fernando; Calasans-Maia, Mônica Diuana; de Mello Machado, Rafael Coutinho; de Brito Resende, Rodrigo Figueiredo; Alves, Gutemberg Gomes

    2018-06-26

    The control of postoperative bleeding represents one of the main intercurrent events associated with soft tissue surgical procedures in the oral cavity. In this context, platelet-rich fibrin (PRF) membranes are materials with great potential for optimizing soft tissue healing and induction of hemostasis. This interventional case series describes the treatment of 10 patients with excisional biopsy of benign oral cavity lesions, following a screening sequence at the surgery clinic of a Brazilian dental school between the years of 2015 and 2017. After treatment with PRF, patients presented mean time for postoperative hemostasis of 10.3 ± 2.5 s, requiring the average use of three membranes to cover the surgical area. The results suggest that the use of platelet-rich fibrin membranes may represent a feasible alternative hemostatic material for the treatment of oral lesions.

  11. Precision Attitude Determination System (PADS) design and analysis. Two-axis gimbal star tracker

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Development of the Precision Attitude Determination System (PADS) focused chiefly on the two-axis gimballed star tracker and electronics design improved from that of Precision Pointing Control System (PPCS), and application of the improved tracker for PADS at geosynchronous altitude. System design, system analysis, software design, and hardware design activities are reported. The system design encompasses the PADS configuration, system performance characteristics, component design summaries, and interface considerations. The PADS design and performance analysis includes error analysis, performance analysis via attitude determination simulation, and star tracker servo design analysis. The design of the star tracker and electronics are discussed. Sensor electronics schematics are included. A detailed characterization of the application software algorithms and computer requirements is provided.

  12. Aspects regarding manufacturing technologies of composite materials for brake pad application

    NASA Astrophysics Data System (ADS)

    Craciun, A. L.; Hepuţ, T.; Pinca-Bretotean, C.

    2018-01-01

    Current needs in road safety, requires the development of new technical solutions for automotive braking system. Their safe operation is subject to following factors: concept design, materials used and electronic control. Among the factors previously listed, choice of materials and manufacturing processes are difficult stage but very important for achieving technical performance and getting a relatively small cost of constituting parts of brake system. The choice is based on the promotion of organic composite material, popular in areas where the weight of materials plays an important role. The brake system is composed of many different parts including brake pads, a master cylinder, wheel cylinders and a hydraulic control system. The brake pads are an important component in the braking system of automotive. These are of different types, suitable for different types of automotive and engines. Brake pads are designed for friction stability, durability, minimization of noise and vibration. The typology of the brake pads depends on the material which they are made. The aim of this paper is to presents the manufacturing technologies for ten recipes of composite material used in brake pads applications. In this work will be done: choosing the constituents of the recipes, investigation of their basic characteristics, setting the proportions of components, obtaining the composite materials in laboratory, establishing the parameters of manufacturing technology and technological analysis.

  13. Media and Technology in Preschool Classrooms: Manifesting Prosocial Sharing Behaviours When Using iPads

    ERIC Educational Resources Information Center

    Ralph, Rachel

    2018-01-01

    This empirical case study investigated prosocial sharing behaviours when using media and technology, i.e., iPads. The following research questions were explored: (1) How do prosocial behaviours of sharing manifest among preschool-aged children interacting with iPads? (2) What are the effects of iPad use on the manifestation of prosocial sharing…

  14. 40 CFR 265.442 - Design and installation of new drip pads.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Design and installation of new drip pads. 265.442 Section 265.442 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Drip Pads §...

  15. 40 CFR 264.572 - Design and installation of new drip pads.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Design and installation of new drip pads. 264.572 Section 264.572 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Drip Pads § 264.572 Design...

  16. High-permittivity thin dielectric padding improves fresh blood imaging of femoral arteries at 3 T.

    PubMed

    Lindley, Marc D; Kim, Daniel; Morrell, Glen; Heilbrun, Marta E; Storey, Pippa; Hanrahan, Christopher J; Lee, Vivian S

    2015-02-01

    Fresh blood imaging (FBI) is a useful noncontrast magnetic resonance angiographic (MRA) method for the assessment of peripheral arterial disease, particularly for imaging patients with poor renal function. Compared with 1.5 T, 3 T enables higher signal-to-noise ratio and/or spatiotemporal resolution in FBI. Indeed, previous studies have reported successful FBI of the calf station at 3 T. However, FBI of the thigh station at 3 T has been reported to suffer from signal void in the common femoral artery of 1 thigh only because of the radial symmetry in transmit radiofrequency field (B1+) variation. We sought to increase the signal of femoral artery in FBI at 3 T using high-permittivity dielectric padding. We performed FBI and B1+ mapping of the thigh station at 3 T in 13 human subjects to compare the following 3 dielectric padding settings: no padding, commercially available thick (approximately 5 cm) dielectric padding, and high-permittivity thin (approximately 2 cm) dielectric padding. We characterized the radial symmetry in B1+ variation as well as its impact on the FBI signal at baseline and how dielectric padding improves B1+ and FBI. We evaluated the quality of 3 FBI MRA acquisitions using quantitative (ie, contrast-to-noise ratio of femoral arteries) and qualitative (ie, conspicuity of femoral arteries) analyses. With the subjects positioned on the magnetic resonance table in feet-first, supine orientation, the radial symmetry in B1+ variation attenuates the signal in the right common femoral artery. The signal void can be improved partially with commercial padding and improved further with high-permittivity padding. Averaging the results over the 13 subjects, the mean B1+, contrast-to-noise ratio, and conspicuity scores for the right common femoral artery were significantly higher with high-permittivity padding than with commercial padding and baseline (P < 0.001). Our study shows that high-permittivity dielectric padding can be used to increase the signal of

  17. Digital representation of oil and natural gas well pad scars in southwest Wyoming: 2012 update

    USGS Publications Warehouse

    Garman, Steven L.; McBeth, Jamie L.

    2015-01-01

    The recent proliferation of oil and natural gas energy development in the Greater Green River Basin of southwest Wyoming has accentuated the need to understand wildlife responses to this development. The location and extent of surface disturbance that is created by oil and natural gas well pad scars are key pieces of information used to assess the effects of energy infrastructure on wildlife populations and habitat. A digital database of oil and natural gas pad scars had previously been generated from 1-meter (m) National Agriculture Imagery Program imagery (NAIP) acquired in 2009 for a 7.7-million hectare (ha) (19,026,700 acres) region of southwest Wyoming. Scars included the pad area where wellheads, pumps, and storage facilities reside and the surrounding area that was scraped and denuded of vegetation during the establishment of the pad. Scars containing tanks, compressors, the storage of oil and gas related equipment, and produced-water ponds were also collected on occasion. This report updates the digital database for the five counties of southwest Wyoming (Carbon, Lincoln, Sublette, Sweetwater, Uinta) within the Wyoming Landscape Conservation Initiative (WLCI) study area and for a limited portion of Fremont, Natrona, and Albany Counties using 2012 1-m NAIP imagery and 2012 oil and natural gas well permit information. This report adds pad scars created since 2009, and updates attributes of all pad scars using the 2012 well permit information. These attributes include the origination year of the pad scar, the number of active and inactive wells on or near each pad scar in 2012, and the overall status of the pad scar (active or inactive). The new 2012 database contains 17,404 pad scars of which 15,532 are attributed as oil and natural gas well pads. Digital data are stored as shapefiles projected to the Universal Transverse Mercator (zones 12 and 13) coordinate system. These data are available from the U.S. Geological Survey (USGS) at http://dx.doi.org/10

  18. Low hemorrhage-related mortality in trauma patients in a Level I trauma center employing transfusion packages and early thromboelastography-directed hemostatic resuscitation with plasma and platelets.

    PubMed

    Johansson, Pär I; Sørensen, Anne Marie; Larsen, Claus F; Windeløv, Nis A; Stensballe, Jakob; Perner, Anders; Rasmussen, Lars S; Ostrowski, Sisse R

    2013-12-01

    Hemorrhage accounts for most preventable trauma deaths, but still the optimal strategy for hemostatic resuscitation remains debated. This was a prospective study of adult trauma patients admitted to a Level I trauma center. Demography, Injury Severity Score (ISS), transfusion therapy, and mortality were registered. Hemostatic resuscitation was based on a massive transfusion protocol encompassing transfusion packages and thromboelastography (TEG)-guided therapy. A total of 182 patients were included (75% males, median age 43 years, ISS of 17, 92% with blunt trauma). Overall 28-day mortality was 12% with causes of death being exsanguinations (14%), traumatic brain injury (72%, two-thirds expiring within 24 hr), and other (14%). One-fourth, 16 and 15% of the patients, received red blood cells (RBCs), plasma, or platelets (PLTs) within 2 hours from admission and 68, 71, and 75%, respectively, of patients transfused within 24 hours received the respective blood products within the first 2 hours. In patients transfused within 24 hours, the median number of blood products at 2 hours was 5 units of RBCs, 5 units of plasma, and 2 units of PLT concentrates. Nonsurvivors had lower clot strength by kaolin-activated TEG and TEG functional fibrinogen and lower kaolin-tissue factor-activated TEG α-angle and lysis after 30 minutes compared to survivors. None of the TEG variables were independent predictors of massive transfusion or mortality. Three-fourths of the patients transfused with plasma or PLTs within 24 hours received these in the first 2 hours. Hemorrhage caused 14% of the deaths. We introduced transfusion packages and early TEG-directed hemostatic resuscitation at our hospital 10 years ago and this may have contributed to reducing hemorrhagic trauma deaths. © 2013 American Association of Blood Banks.

  19. Comparing performance on the MNREAD iPad application with the MNREAD acuity chart.

    PubMed

    Calabrèse, Aurélie; To, Long; He, Yingchen; Berkholtz, Elizabeth; Rafian, Paymon; Legge, Gordon E

    2018-01-01

    Our purpose was to compare reading performance measured with the MNREAD Acuity Chart and an iPad application (app) version of the same test for both normally sighted and low-vision participants. Our methods included 165 participants with normal vision and 43 participants with low vision tested on the standard printed MNREAD and on the iPad app version of the test. Maximum Reading Speed, Critical Print Size, Reading Acuity, and Reading Accessibility Index were compared using linear mixed-effects models to identify any potential differences in test performance between the printed chart and the iPad app. Our results showed the following: For normal vision, chart and iPad yield similar estimates of Critical Print Size and Reading Acuity. The iPad provides significantly slower estimates of Maximum Reading Speed than the chart, with a greater difference for faster readers. The difference was on average 3% at 100 words per minute (wpm), 6% at 150 wpm, 9% at 200 wpm, and 12% at 250 wpm. For low vision, Maximum Reading Speed, Reading Accessibility Index, and Critical Print Size are equivalent on the iPad and chart. Only the Reading Acuity is significantly smaller (I. E., better) when measured on the digital version of the test, but by only 0.03 logMAR (p = 0.013). Our conclusions were that, overall, MNREAD parameters measured with the printed chart and the iPad app are very similar. The difference found in Maximum Reading Speed for the normally sighted participants can be explained by differences in the method for timing the reading trials.

  20. Comparing performance on the MNREAD iPad application with the MNREAD acuity chart

    PubMed Central

    Calabrèse, Aurélie; To, Long; He, Yingchen; Berkholtz, Elizabeth; Rafian, Paymon; Legge, Gordon E.

    2018-01-01

    Our purpose was to compare reading performance measured with the MNREAD Acuity Chart and an iPad application (app) version of the same test for both normally sighted and low-vision participants. Our methods included 165 participants with normal vision and 43 participants with low vision tested on the standard printed MNREAD and on the iPad app version of the test. Maximum Reading Speed, Critical Print Size, Reading Acuity, and Reading Accessibility Index were compared using linear mixed-effects models to identify any potential differences in test performance between the printed chart and the iPad app. Our results showed the following: For normal vision, chart and iPad yield similar estimates of Critical Print Size and Reading Acuity. The iPad provides significantly slower estimates of Maximum Reading Speed than the chart, with a greater difference for faster readers. The difference was on average 3% at 100 words per minute (wpm), 6% at 150 wpm, 9% at 200 wpm, and 12% at 250 wpm. For low vision, Maximum Reading Speed, Reading Accessibility Index, and Critical Print Size are equivalent on the iPad and chart. Only the Reading Acuity is significantly smaller (I. E., better) when measured on the digital version of the test, but by only 0.03 logMAR (p = 0.013). Our conclusions were that, overall, MNREAD parameters measured with the printed chart and the iPad app are very similar. The difference found in Maximum Reading Speed for the normally sighted participants can be explained by differences in the method for timing the reading trials. PMID:29351351

  1. Reading Nonfiction Text on an iPad in a Secondary Classroom

    ERIC Educational Resources Information Center

    Cardullo, Victoria; Zygouris-Coe, Vassiliki I.; Wilson, Nance S.

    2017-01-01

    The intent of this research was to investigate the experiences of eighth grade readers as they read nonfiction text on an iPad for academic purposes. We investigated reading strategies that students use to support their reading as well as what role iPad features played in the reading process. New literacies, metacognition and transactional…

  2. Touch, Type, and Transform: iPads in the Social Studies Classroom

    ERIC Educational Resources Information Center

    Berson, Ilene R.; Berson, Michael J.; Manfra, Meghan McGlinn

    2012-01-01

    The release of Apple's iPad was met with great enthusiasm by educators and schools. Yet, if this new technology is retrofitted to traditional teaching activities its full potential will go unrealized. The presence of iPads alone will not generate transformative educational experiences in the social studies; however, the appropriation of the device…

  3. Orion Pad Abort 1 Flight Test: Simulation Predictions Versus Flight Data

    NASA Technical Reports Server (NTRS)

    Stillwater, Ryan Allanque; Merritt, Deborah S.

    2011-01-01

    The presentation covers the pre-flight simulation predictions of the Orion Pad Abort 1. The pre-flight simulation predictions are compared to the Orion Pad Abort 1 flight test data. Finally the flight test data is compared to the updated simulation predictions, which show a ove rall improvement in the accuracy of the simulation predictions.

  4. Comparative Evaluation of Biological Performance, Biosecurity, and Availability of Cellulose-Based Absorbable Hemostats.

    PubMed

    Wu, Yadong; Wang, Fang; Huang, Yudong

    2018-05-01

    Hemorrhage remains a leading cause of death after trauma, and developing a hemostat with excellent performance and good biosecurity is an extremely active area of research and commercial product development. Although oxidized regenerated cellulose (ORC) has been developed to address these problems, it is not always efficient and its biosecurity is not perfect. We aimed to refine ORC via a simple and mild neutralization method. The prepared neutralized oxidized regenerated cellulose (NORC) showed a superior gel property due to its chemical structure. The biological performance of both ORC and NORC was systematically evaluated; the results showed that ORC would induce erythema and edema in the irritation test, whereas NORC did not cause any adverse inflammation, indicating NORC had desirable biocompatibility. We further demonstrated that NORC confirmed to the toxicity requirements of International Organization for Standardization (ISO) standards; however, ORC showed an unacceptable cytotoxicity. The rabbit hepatic defect model stated that NORC exhibited better ability of hemostasis, which was attributed to its significant gel performance in physiological environment.

  5. SpaceX Pad39A Event

    NASA Image and Video Library

    2017-02-17

    Members of the news media are at Launch Complex 39A for a briefing from Kennedy Space Center Director Bob Cabana; Gwynee Shotwell, president and chief operating officer of SpaceX; and Timothy Hughes, senior vice president and general counsel for SpaceX. On Feb. 18, a Falcon 9 rocket with a Dragon spacecraft atop is scheduled to lift off from the launch pad for the SpaceX CRS-10 mission. The historic site is where American astronauts first launched to the moon and was last used in 2011 for the final mission of the Space Shuttle Program. In April 2014, NASA officials signed a 20-year property agreement with SpaceX for use and operation of the launch pad for their Falcon 9 and Falcon 9 Heavy rockets. The SpaceX CRS-10 liftoff is another milestone further establishing Kennedy as a premier, multi-user spaceport. The Dragon spacecraft will deliver 5,000 pounds of supplies and research materials to the space station.

  6. SpaceX Pad39A Event

    NASA Image and Video Library

    2017-02-17

    Kennedy Space Center Director Bob Cabana speaks to members of the news media at Launch Complex 39A. At left is Gwynne Shotwell, president and chief operating officer of SpaceX. At right is Timothy Hughes, senior vice president and general counsel for SpaceX. On Feb. 18, a Falcon 9 rocket with a Dragon spacecraft atop is scheduled to lift off from the launch pad for the SpaceX CRS-10 mission. The historic site is where American astronauts first launched to the moon and was last used in 2011 for the final mission of the Space Shuttle Program. In April 2014, NASA officials signed a 20-year property agreement with SpaceX for use and operation of the launch pad for their Falcon 9 and Falcon 9 Heavy rockets. The SpaceX CRS-10 liftoff is another milestone further establishing Kennedy as a premier, multi-user spaceport. The Dragon spacecraft will deliver 5,000 pounds of supplies and research materials to the space station.

  7. SpaceX Pad39A Event

    NASA Image and Video Library

    2017-02-17

    Gwynne Shotwell, president and chief operating officer of SpaceX, speaks to members of the news media at Launch Complex 39A. At left is Kennedy Space Center Director Bob Cabana. At right is Timothy Hughes, senior vice president and general counsel for SpaceX. On Feb. 18, a Falcon 9 rocket with a Dragon spacecraft atop is scheduled to lift off from the launch pad for the SpaceX CRS-10 mission. The historic site is where American astronauts first launched to the moon and was last used in 2011 for the final mission of the Space Shuttle Program. In April 2014, NASA officials signed a 20-year property agreement with SpaceX for use and operation of the launch pad for their Falcon 9 and Falcon 9 Heavy rockets. The SpaceX CRS-10 liftoff is another milestone further establishing Kennedy as a premier, multi-user spaceport. The Dragon spacecraft will deliver 5,000 pounds of supplies and research materials to the space station.

  8. SpaceX Pad39A Event

    NASA Image and Video Library

    2017-02-17

    Timothy Hughes, senior vice president and general counsel for SpaceX speaks to members of the news media at Launch Complex 39A. Behind him, from left, are Kennedy Space Center Director Bob Cabana and Gwynne Shotwell, president and chief operating officer of SpaceX. On Feb. 18, a Falcon 9 rocket with a Dragon spacecraft atop is scheduled to lift off from the launch pad for the SpaceX CRS-10 mission. The historic site is where American astronauts first launched to the moon and was last used in 2011 for the final mission of the Space Shuttle Program. In April 2014, NASA officials signed a 20-year property agreement with SpaceX for use and operation of the launch pad for their Falcon 9 and Falcon 9 Heavy rockets. The SpaceX CRS-10 liftoff is another milestone further establishing Kennedy as a premier, multi-user spaceport. The Dragon spacecraft will deliver 5,000 pounds of supplies and research materials to the space station.

  9. Prevent P.A.D.: Know Your Numbers

    MedlinePlus

    ... weight, exercise, and adopt healthy habits." Activities and Events To raise awareness about P.A.D., NHLBI, ... September, a number of local partners hold screening events in their communities. Education and Outreach to Health ...

  10. The Effect of Reworking Underfilled Components on Pad Strength

    NASA Astrophysics Data System (ADS)

    Feigel, Andrew

    Reworkable underfills represent a significant step in electronic packaging technologies, however they are still relatively unstudied compared to traditional underfills. To help understand the properties of these underfills, four newly developed underfills were studied with the assistance of the companies which developed them. Of primary concern is how does the thermal cycling, and subsequent rework of larger BGA components effect pad strength on the substrate. To study this a detailed rework procedure was developed which worked well for all underfills studied. Within the development of the rework procedure a discovery was made effecting reworkability. After an initial breakdown of the underfill during reflow conditions, further rework was possible at lowered temperatures. This development was not listed in any of the company provided rework procedures. Pad strength was measured with hot bump pull testing. This showed that while the inherent variance is quite large, there are still measurable effects of thermal cycling on pad strength after rework. Trends for the number of cycles causing the overall strength of the pads to be relatively stronger or weaker, vary depending on the material. This research sets a solid groundwork for future research into reworkable underfills, with a detailed rework process. Future avenues of research include: effects of rework on component lifetimes in thermal cycling, mechanics behind lower temperature of rework after initial breakdown of underfill, and effects of reworked substrates on underfill flow rates and void formation.

  11. Modulation of Interleukins in Sepsis-Associated Clotting Disorders: Interplay With Hemostatic Derangement.

    PubMed

    Low, Christopher; Syed, Daneyal; Khan, Daniel; Tetik, Sermin; Walborn, Amanda; Hoppensteadt, Debra; Mosier, Michael; Fareed, Jawed

    2017-01-01

    Interleukins play a central role in the immune system and are involved in a variety of immunological, inflammatory, and infectious disease states including sepsis syndrome. Levels of interleukins may correlate with overall survival and may directly or indirectly affect some of the regulators of coagulation and fibrinolysis, thereby disrupting hemostasis and thrombosis. Our hypothesis is that in sepsis-associated coagulopathies (SACs), interleukins may be upregulated, leading to hemostatic imbalance by generating thrombogenic mediators. We profiled the levels of interleukins IL-1α, IL-1β, IL-2, IL-4, IL-6, IL-8, and IL-10 in addition to d-dimer (DD) in patients with SAC and in normal donors. We observed the highest increase in interleukins IL-6 (322-fold), IL-8 (48-fold), IL-10 (72-fold), and DD (18-fold). This suggests that interleukins such as IL-6 and IL-10 have a close association with coagulopathy and fibrinolytic dysregulation in sepsis and can be considered as candidates for potential therapeutic targets in SAC. © The Author(s) 2016.

  12. Does It Matter Whether One Takes a Test on an iPad or a Desktop Computer?

    ERIC Educational Resources Information Center

    Ling, Guangming

    2016-01-01

    To investigate possible iPad related mode effect, we tested 403 8th graders in Indiana, Maryland, and New Jersey under three mode conditions through random assignment: a desktop computer, an iPad alone, and an iPad with an external keyboard. All students had used an iPad or computer for six months or longer. The 2-hour test included reading, math,…

  13. Experimental evaluation of foil-supported resilient-pad gas-lubricated thrust bearing

    NASA Technical Reports Server (NTRS)

    Nemeth, Z. N.

    1977-01-01

    A new type of resilient-pad gas thrust bearing was tested to determine the feasibility of the design. The bearing consists of carbon graphite pads mounted asymmetrically on foil beams. Two bearing configurations were tested at thrust loads from 27 to 80 newtons at speeds to 9000 rpm. The outside diameter of the bearing was 8.9 centimeters.

  14. Examining Teachers' Use of iPads: Comfort Level, Perception, and Use

    ERIC Educational Resources Information Center

    Liu, Min; Navarrete, Cesar C.; Scordino, Robert; Kang, Jina; Ko, Yujung; Lim, Mihyun

    2016-01-01

    While there is evidence of the growing popularity of iPads and other tablets in K-12 education, little is understood about how teachers use these devices in their instruction. This study examines 342 teachers' comfort level with and perception toward iPad use and any changes that occurred over the implementation year. Using a mixed-methods design,…

  15. Student Perceptions of iPads as Mobile Learning Devices for Fieldwork

    ERIC Educational Resources Information Center

    Welsh, Katharine E.; Mauchline, Alice L.; Powell, Victoria; France, Derek; Park, Julian R.; Whalley, W. Brian

    2015-01-01

    This paper reports findings from six field courses about student's perceptions of iPads as mobile learning devices for fieldwork. Data were collected through surveys and focus groups. The key findings suggest that the multi-tool nature of the iPads and their portability were the main strengths. Students had some concerns over the safety of the…

  16. Effect of pressure and padding on motion artifact of textile electrodes.

    PubMed

    Cömert, Alper; Honkala, Markku; Hyttinen, Jari

    2013-04-08

    With the aging population and rising healthcare costs, wearable monitoring is gaining importance. The motion artifact affecting dry electrodes is one of the main challenges preventing the widespread use of wearable monitoring systems. In this paper we investigate the motion artifact and ways of making a textile electrode more resilient against motion artifact. Our aim is to study the effects of the pressure exerted onto the electrode, and the effects of inserting padding between the applied pressure and the electrode. We measure real time electrode-skin interface impedance, ECG from two channels, the motion artifact related surface potential, and exerted pressure during controlled motion by a measurement setup designed to estimate the relation of motion artifact to the signals. We use different foam padding materials with various mechanical properties and apply electrode pressures between 5 and 25 mmHg to understand their effect. A QRS and noise detection algorithm based on a modified Pan-Tompkins QRS detection algorithm estimates the electrode behaviour in respect to the motion artifact from two channels; one dominated by the motion artifact and one containing both the motion artifact and the ECG. This procedure enables us to quantify a given setup's susceptibility to the motion artifact. Pressure is found to strongly affect signal quality as is the use of padding. In general, the paddings reduce the motion artifact. However the shape and frequency components of the motion artifact vary for different paddings, and their material and physical properties. Electrode impedance at 100 kHz correlates in some cases with the motion artifact but it is not a good predictor of the motion artifact. From the results of this study, guidelines for improving electrode design regarding padding and pressure can be formulated as paddings are a necessary part of the system for reducing the motion artifact, and further, their effect maximises between 15 mmHg and 20 mmHg of

  17. A three-dimensional inverse finite element analysis of the heel pad.

    PubMed

    Chokhandre, Snehal; Halloran, Jason P; van den Bogert, Antonie J; Erdemir, Ahmet

    2012-03-01

    Quantification of plantar tissue behavior of the heel pad is essential in developing computational models for predictive analysis of preventive treatment options such as footwear for patients with diabetes. Simulation based studies in the past have generally adopted heel pad properties from the literature, in return using heel-specific geometry with material properties of a different heel. In exceptional cases, patient-specific material characterization was performed with simplified two-dimensional models, without further evaluation of a heel-specific response under different loading conditions. The aim of this study was to conduct an inverse finite element analysis of the heel in order to calculate heel-specific material properties in situ. Multidimensional experimental data available from a previous cadaver study by Erdemir et al. ("An Elaborate Data Set Characterizing the Mechanical Response of the Foot," ASME J. Biomech. Eng., 131(9), pp. 094502) was used for model development, optimization, and evaluation of material properties. A specimen-specific three-dimensional finite element representation was developed. Heel pad material properties were determined using inverse finite element analysis by fitting the model behavior to the experimental data. Compression dominant loading, applied using a spherical indenter, was used for optimization of the material properties. The optimized material properties were evaluated through simulations representative of a combined loading scenario (compression and anterior-posterior shear) with a spherical indenter and also of a compression dominant loading applied using an elevated platform. Optimized heel pad material coefficients were 0.001084 MPa (μ), 9.780 (α) (with an effective Poisson's ratio (ν) of 0.475), for a first-order nearly incompressible Ogden material model. The model predicted structural response of the heel pad was in good agreement for both the optimization (<1.05% maximum tool force, 0.9% maximum tool

  18. Dermal exposure assessment to benzene and toluene using charcoal cloth pads.

    PubMed

    van Wendel de Joode, Berna; Tielemans, Erik; Vermeulen, Roel; Wegh, Hillion; Kromhout, Hans

    2005-01-01

    Charcoal cloth pads have been used to assess volatile chemicals on the skin in a laboratory setting; however, they have not yet been applied to measure dermal exposure in occupational settings. This study aimed at evaluating whether charcoal pads can be used to assess dermal exposure to benzene and toluene in workers of a petrochemical plant. Inhalation and dermal exposure levels to benzene and toluene were assessed for workers of a petrochemical plant performing different jobs. Benzene uptake was assessed by determining S-phenylmercapturic acid in workers' urine samples. Dermal exposure levels on the charcoal pads were adjusted for ambient air levels of benzene and toluene by subtracting the amount of benzene or toluene measured in personal air from the amount of benzene or toluene measured on the charcoal pad. In general, measured external and internal exposure levels were low. The estimated contribution of the dermal route to internal benzene exposure levels was less than 0.06% for all jobs. Toluene personal air concentrations and benzene and toluene dermal exposure levels differed statistically significantly between job titles. For benzene, differences between jobs were larger for adjusted dermal exposures (maximum 17-fold, P = 0.02) than for inhalation exposures (maximum two-fold, P = 0.08). Also for toluene, although less clear, differences between jobs were larger for adjusted dermal exposures (maximum 23-fold, P = 0.01) as compared to inhalation exposures (maximum 10-fold, P = 0.01). Charcoal pads appeared to measure dermal exposures to benzene and toluene in addition to ambient air levels. Future studies applying charcoal cloth pads for the dermal exposure assessment at workplaces with higher dermal exposure to organic solvents may provide more insight into the biological relevance of dermal exposure levels measured by charcoal cloth pads. In addition, the design of the dermal sampler might be improved by configuring a dermal sampler, where part of the

  19. Assessment of the Apple iPad as a low-vision reading aid.

    PubMed

    Morrice, E; Johnson, A P; Marinier, J-A; Wittich, W

    2017-06-01

    PurposeLow-vision clients frequently report having problems with reading. Using magnification, reading performance (as measured by reading speed) can be improved by up to 200%. Current magnification aids can be expensive or bulky; therefore, we explored if the Apple iPad offers comparable performance in improving reading speeds, in comparison with a closed-circuit television (CCTV) video magnifier, or other magnification devices.MethodsWe recruited 100 participants between the ages of 24-97 years, with low vision who were literate and cognitively capable, of whom 57 had age-related macular degeneration. To assess reading, participants read standardized iReST texts and were tested for comprehension. We compared reading speed on the Apple iPad (10 inch) with that of the CCTV, home magnification devices, and baseline measures.ResultsAll assistive devices improved reading rates in comparison to baseline (P<0.001, Hedge's g>1), however, there was no difference in improvement across devices (P>0.05, Hedge's g<0.1). When experience was taken into account, those with iPad experience read, on average, 30 words per minute faster than first time iPad users, whereas CCTV experience did not influence reading speed.ConclusionsIn our sample, the Apple iPad was as effective as currently used technologies for improving reading rates. Moreover, exposure to, and experience with the Apple iPad might increase reading speed with that device. A larger sample size, however, is needed to do subgroup analysis on who would optimally benefit from each type of magnification device.

  20. Assessment of the Apple iPad as a low-vision reading aid

    PubMed Central

    Morrice, E; Johnson, A P; Marinier, J-A; Wittich, W

    2017-01-01

    Purpose Low-vision clients frequently report having problems with reading. Using magnification, reading performance (as measured by reading speed) can be improved by up to 200%. Current magnification aids can be expensive or bulky; therefore, we explored if the Apple iPad offers comparable performance in improving reading speeds, in comparison with a closed-circuit television (CCTV) video magnifier, or other magnification devices. Methods We recruited 100 participants between the ages of 24–97 years, with low vision who were literate and cognitively capable, of whom 57 had age-related macular degeneration. To assess reading, participants read standardized iReST texts and were tested for comprehension. We compared reading speed on the Apple iPad (10 inch) with that of the CCTV, home magnification devices, and baseline measures. Results All assistive devices improved reading rates in comparison to baseline (P<0.001, Hedge’s g>1), however, there was no difference in improvement across devices (P>0.05, Hedge’s g<0.1). When experience was taken into account, those with iPad experience read, on average, 30 words per minute faster than first time iPad users, whereas CCTV experience did not influence reading speed. Conclusions In our sample, the Apple iPad was as effective as currently used technologies for improving reading rates. Moreover, exposure to, and experience with the Apple iPad might increase reading speed with that device. A larger sample size, however, is needed to do subgroup analysis on who would optimally benefit from each type of magnification device. PMID:28157222

  1. LEAVING PAD - ASTRONAUT JOHN W. YOUNG - TRAINING

    NASA Image and Video Library

    1965-03-19

    S65-20636 (1965) --- Astronauts John W. Young (left), pilot, and Virgil I. Grissom, command pilot, for the Gemini-Titan 3 flight, are shown leaving the launch pad after simulations in the Gemini-3 spacecraft.

  2. Using iPads to illustrate the impulse-momentum relationship

    NASA Astrophysics Data System (ADS)

    Streepey, Jefferson W.

    2013-01-01

    One of the fundamental challenges in teaching is making the students able to transform course material in ways that help them solve "real world" problems. Sophisticated mobile technology (such as smartphones, iPads, or iTouches) offers students an opportunity to apply physics content to a broad range of scenarios to enhance their understanding and improve their class engagement. For the outlined example, students in an upper-level biomechanics class used the native accelerometers in iPads to record and analyze human movement. This activity allowed the students to experiment with the impulse-momentum relationship.

  3. The fine structure of the rectal pads of Zorotypus caudelli Karny (Zoraptera, Insecta).

    PubMed

    Dallai, R; Mercati, D; Mashimo, Y; Machida, R; Beutel, R G

    2016-07-01

    The rectal pads of a species of the controversial polyneopteran order Zoraptera were examined using histological sections and TEM micrographs. Six pads are present along the thin rectal epithelium. Each pad consists of a few large principal cells surrounded by flattened junctional cells, which extend also beneath the principal cells. The cells are lined by a thin apical cuticle. No basal cells and no cavity have been observed beneath the pad. Principal cells have a regular layer of apical microvilli and are joined by intercellular septate junctions, which are interrupted by short dilatations of the intercellular space. At these levels the two adjacent plasma membranes are joined by short zonulae adhaerentes. In the cytoplasm, a rich system of strict associations between lateral plasma membranes and mitochondria forms scalariform junctions. Rectal pads share ultrastructural features with similar excretory organs of several neopteran groups, in particular with Blattodea (roaches and termites) and Thysanoptera, and are involved in fluid reabsorption and ion regulation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Real-world surgical outcomes of a gelatin-hemostatic matrix in women requiring a hysterectomy: a matched case-control study.

    PubMed

    Obermair, Helena; Janda, Monika; Obermair, Andreas

    2016-09-01

    The aim of this study was to compare adverse events and surgical outcomes of hysterectomy with or without use of a gelatin-hemostatic matrix (SURGIFLO(®) ). Prospective case-control study (Canadian Task Force classification II2) of total hysterectomy (Piver Type 1) provided by surgeons in Australia between November 2005 and May 2015. Data were collected via SurgicalPerformance, a web-based data project which aims to provide confidential feedback to surgeons about their surgical outcomes. Of 2440 records of women who received a hysterectomy, 1351 were eligible for these analyses; 107 received SURGIFLO(®) hemostatic matrix to prevent postoperative blood loss and 1244 did not. Patients with or without SURGIFLO(®) differed in age, Charlson comorbidity index, and American Society of Anesthesiologists physical status classification system score (ASA), and also differed in clinical outcomes. After matching for patient's age and ASA at surgery, patients with and without SURGIFLO(®) had comparable baseline characteristics. Matched patients with and without SURGIFLO(®) had comparable clinical outcomes including risk of developing vault hematoma, return to the operating room, transfusion of red cells, surgical site infection (pelvis), readmission within 30 days and unplanned ICU admission. In a sample matched by age and ASA, SURGIFLO(®) neither prevented nor caused additional adverse events in women undergoing hysterectomy. Surgeons used SURGIFLO(®) more commonly among women who were older, had more comorbidities and a higher ASA score. This indicates that it may be most useful in complicated surgery or cases. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.

  5. 77 FR 50508 - Brain-Pad, Inc; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-21

    ... FEDERAL TRADE COMMISSION [File No. 122 3073] Brain-Pad, Inc; Analysis of Proposed Consent Order To... instructions in the Request for Comment part of the SUPPLEMENTARY INFORMATION section below. Write ``Brain-Pad... September 17, 2012. Write ``Brain-Pad, File No. 122 3073'' on your comment. Your comment--including your...

  6. Biomechanics of ant adhesive pads: frictional forces are rate- and temperature-dependent.

    PubMed

    Federle, Walter; Baumgartner, Werner; Hölldobler, Bert

    2004-01-01

    Tarsal adhesive pads enable insects to hold on to smooth plant surfaces. Using a centrifuge technique, we tested whether a "wet adhesion" model of a thin film of liquid secreted between the pad and the surface can explain adhesive and frictional forces in Asian Weaver ants (Oecophylla smaragdina). When forces are acting parallel to the surface, pads in contact with the surface can slide smoothly. Force per unit pad contact area was strongly dependent on sliding velocity and temperature. Seemingly consistent with the effect of a thin liquid film in the contact zone, (1) frictional force linearly increased with sliding velocity, (2) the increment was greater at lower temperatures and (3) no temperature dependence was detected for low-rate perpendicular detachment forces. However, we observed a strong, temperature-independent static friction that was inconsistent with a fully lubricated contact. Static friction was too large to be explained by the contribution of other (sclerotized) body parts. Moreover, the rate-specific increase of shear stress strongly exceeded predictions derived from estimates of the adhesive liquid film's thickness and viscosity. Both lines of evidence indicate that the adhesive secretion alone is insufficient to explain the observed forces and that direct interaction of the soft pad cuticle with the surface ("rubber friction") is involved.

  7. Performance evaluation of three different types of local evaporative cooling pads in greenhouses in Sudan.

    PubMed

    Ahmed, Egbal Mohammed; Abaas, Osama; Ahmed, Mohammed; Ismail, Mohd Rodzi

    2011-01-01

    This study was conducted in Date Palm Technology Company Limited, Shambat, Khartoum State. To evaluate performance of three types of evaporative cooling pads for greenhouses (celdek pads, straw pads and sliced wood pads), as compared to the conditions outside the greenhouses (control), for pads. Performance evaluation includes environmental parameters (temperature and relative humidity at 8 am, 1 pm and 6 pm) and crop parameters (length and stem diameter, leaves number and width, fruit length and diameter, fruit weight and dry matter and yield). The results obtained for the temperature at 8 am showed that there was no significant difference (0.05) inside the greenhouses, while a high significant difference between the conditions inside and outside of the greenhouses was found. Significant differences were found at 1 pm and 6 pm between all treatments as compared to the conditions outside the greenhouses, and the results obtained for relative humidity showed high significant differences at 8 am and 1 pm inside the greenhouses and between inside and outside the greenhouse, respectively, while there was no significant difference at 6 pm inside the greenhouses and between inside and outside the greenhouses. On the other hand, the results obtained for crop parameters showed that there were significant differences between all parameters inside the greenhouses and outside the greenhouses; however, the greenhouses with sliced wood pads gave the highest yield and the greenhouses with straw pads gave the least and conditions outside gave the lowest. This study indicated that the sliced wood pads are better than the other evaporative cooling pads.

  8. Liquid transmission characteristics of padding bandages under pressure.

    PubMed

    Kumar, Bipin; Das, Apurba; Pan, Ning; Alagirusamy, R; Gupta, Rupali; Singh, Jitender

    2015-11-01

    Padding is an essential component in a multilayer compression bandaging system, used inside the compression bandage through which substantial amount of pressure is exerted on the limb of patient for treatment of venous leg ulcers. As a result, the liquid transmission behavior of padding is also critical in managing body fluids or sweat exuded from the affected limb, reducing the excessive moisture build-up around the wound and thereby ensuring comfort to and hence a better compliance from the patients. This study investigates the in-plane fluid transport characteristics of needle-punched nonwoven padding bandages. It first reviewed the existing studies related to the problems, and discussed their limits and possible improvements in dealing with complex fluid transport issues in textile porous media. The measurement of fluid transport under different pressure levels was then done using a newly designed apparatus capable of simultaneously tracing the liquid in-plane spreading along different directions, and obtaining several transport characteristics of a testing sample, e.g. the liquid flow anisotropy, the rate of movement, the area of wet surface with time, etc. Also the effects of several important factors, such as the levels of pressure applied, the specimen bulk density, and needling density of the padding products, have been experimentally investigated. In addition, based on an extended Lucas-Washburn theory, we calculated the liquid flow distance, both instantaneous speed and a more useful time-averaged speed v(av) at any given direction, and also defined a flow anisotropy index I(A) as a convenient parameter to represent the material flow anisotropy. The applications of v(av) and I(A) to actual samples have demonstrated the usefulness of these parameters in characterizing the flow nature and behavior of the materials. © The Author(s) 2015.

  9. Expectations of iPad use in an internal medicine residency program: is it worth the "hype"?

    PubMed

    Luo, Nancy; Chapman, Christopher G; Patel, Bhakti K; Woodruff, James N; Arora, Vineet M

    2013-05-08

    While early reports highlight the benefits of tablet computing in hospitals, introducing any new technology can result in inflated expectations. The aim of the study is to compare anticipated expectations of Apple iPad use and perceptions after deployment among residents. 115 internal medicine residents received Apple iPads in October 2010. Residents completed matched surveys on anticipated usage and perceptions after distribution 1 month prior and 4 months after deployment. In total, 99% (114/115) of residents responded. Prior to deployment, most residents believed that the iPad would improve patient care and efficiency on the wards; however, fewer residents "strongly agreed" after deployment (34% vs 15% for patient care, P<.001; 41% vs 24% for efficiency, P=.005). Residents with higher expectations were more likely to report using the iPad for placing orders post call and during admission (71% vs 44% post call, P=.01, and 16% vs 0% admission, P=.04). Previous Apple iOS product owners were also more likely to use the iPad in key areas. Overall, 84% of residents thought the iPad was a good investment for the residency program, and over half of residents (58%) reported that patients commented on the iPad in a positive way. While the use of tablets such as the iPad by residents is generally well received, high initial expectations highlight the danger of implementing new technologies. Education on the realistic expectations of iPad benefits may be warranted.

  10. Ectopic expression of AtPAD4 broadens resistance of soybean to soybean cyst and root-knot nematodes.

    PubMed

    Youssef, Reham M; MacDonald, Margaret H; Brewer, Eric P; Bauchan, Gary R; Kim, Kyung-Hwan; Matthews, Benjamin F

    2013-04-25

    The gene encoding PAD4 (PHYTOALEXIN-DEFICIENT4) is required in Arabidopsis for expression of several genes involved in the defense response to Pseudomonas syringae pv. maculicola. AtPAD4 (Arabidopsis thaliana PAD4) encodes a lipase-like protein that plays a regulatory role mediating salicylic acid signaling. We expressed the gene encoding AtPAD4 in soybean roots of composite plants to test the ability of AtPAD4 to deter plant parasitic nematode development. The transformed roots were challenged with two different plant parasitic nematode genera represented by soybean cyst nematode (SCN; Heterodera glycines) and root-knot nematode (RKN; Meloidogyne incognita). Expression of AtPAD4 in soybean roots decreased the number of mature SCN females 35 days after inoculation by 68 percent. Similarly, soybean roots expressing AtPAD4 exhibited 77 percent fewer galls when challenged with RKN. Our experiments show that AtPAD4 can be used in an economically important crop, soybean, to provide a measure of resistance to two different genera of nematodes.

  11. Gas Seal Pad With Herringbone-Grooved Rotor-Stiffness and Load Capacity

    NASA Technical Reports Server (NTRS)

    Flemming, David P.

    2006-01-01

    The principle of herringbone-grooved journal bearings has been applied to the case of a seal disc running under a finger seal pad. The inward pumping action of herringbone grooves on the disc generates load capacity and stiffness to maintain a fluid film and prevent contact of the pad and disc. This mechanism does not depend on a converging film under the pad, such as analyzed in previous works. Analysis shows that significant stiffness and load capacity can be supplied by herringbone grooves. In order for the grooves to be effective, the seal pressure drop must be taken outside of the grooved portion of the rotor, but this may be acceptable in order to gain freedom from maintaining a precise film convergence.

  12. iPad: Semantic annotation and markup of radiological images.

    PubMed

    Rubin, Daniel L; Rodriguez, Cesar; Shah, Priyanka; Beaulieu, Chris

    2008-11-06

    Radiological images contain a wealth of information,such as anatomy and pathology, which is often not explicit and computationally accessible. Information schemes are being developed to describe the semantic content of images, but such schemes can be unwieldy to operationalize because there are few tools to enable users to capture structured information easily as part of the routine research workflow. We have created iPad, an open source tool enabling researchers and clinicians to create semantic annotations on radiological images. iPad hides the complexity of the underlying image annotation information model from users, permitting them to describe images and image regions using a graphical interface that maps their descriptions to structured ontologies semi-automatically. Image annotations are saved in a variety of formats,enabling interoperability among medical records systems, image archives in hospitals, and the Semantic Web. Tools such as iPad can help reduce the burden of collecting structured information from images, and it could ultimately enable researchers and physicians to exploit images on a very large scale and glean the biological and physiological significance of image content.

  13. Toxicity of Aluminum Silicates Used in Hemostatic Dressings Toward Human Umbilical Veins Endothelial Cells, HeLa Cells, and RAW267.4 Mouse Macrophages

    DTIC Science & Technology

    2011-09-01

    ORIGINAL ARTICLE Toxicity of Aluminum Silicates Used in Hemostatic Dressings Toward Human Umbilical Veins Endothelial Cells, HeLa Cells, and RAW267.4...not known. Clay minerals are generally considered nontoxic to humans and have been widely used in cosmetics and as excipient in drugs and foods...Bentonite, which has a long history in pharmaceutical formulations,7 along with kaolin are listed in the US Pharmacopeia.8 The sensitivity of some human

  14. New Encryption Scheme of One-Time Pad Based on KDC

    NASA Astrophysics Data System (ADS)

    Xie, Xin; Chen, Honglei; Wu, Ying; Zhang, Heng; Wu, Peng

    As more and more leakage incidents come up, traditional encryption system has not adapted to the complex and volatile network environment, so, there should be a new encryption system that can protect information security very well, this is the starting point of this paper. Based on DES and RSA encryption system, this paper proposes a new scheme of one time pad, which really achieves "One-time pad" and provides information security a new and more reliable encryption method.

  15. Endeavour on way to Pad 39B for STS-77

    NASA Technical Reports Server (NTRS)

    1996-01-01

    A road sign points the way to Launch Pad 39B, the final earthly destination for the Space Shuttle Endeavour and its steppingstone into space. Endeavour began the slow journey from the Vehicle Assembly Building at about 10 a.m., April 16, perched atop the mobile launcher platform and carried by the crawler-transporter. Upcoming activities at the pad to prepare Endeavour for flight on Mission STS-77 include installation of the payloads in the orbiter's payload bay.

  16. Reversible adhesion switching of porous fibrillar adhesive pads by humidity.

    PubMed

    Xue, Longjian; Kovalev, Alexander; Dening, Kirstin; Eichler-Volf, Anna; Eickmeier, Henning; Haase, Markus; Enke, Dirk; Steinhart, Martin; Gorb, Stanislav N

    2013-01-01

    We report reversible adhesion switching on porous fibrillar polystyrene-block-poly(2-vinyl pyridine) (PS-b-P2VP) adhesive pads by humidity changes. Adhesion at a relative humidity of 90% was more than nine times higher than at a relative humidity of 2%. On nonporous fibrillar adhesive pads of the same material, adhesion increased only by a factor of ~3.3. The switching performance remained unchanged in at least 10 successive high/low humidity cycles. Main origin of enhanced adhesion at high humidity is the humidity-induced decrease in the elastic modulus of the polar component P2VP rather than capillary force. The presence of spongelike continuous internal pore systems with walls consisting of P2VP significantly leveraged this effect. Fibrillar adhesive pads on which adhesion is switchable by humidity changes may be used for preconcentration of airborne particulates, pollutants, and germs combined with triggered surface cleaning.

  17. Internal strain estimation for quantification of human heel pad elastic modulus: A phantom study.

    PubMed

    Holst, Karen; Liebgott, Hervé; Wilhjelm, Jens E; Nikolov, Svetoslav; Torp-Pedersen, Søren T; Delachartre, Philippe; Jensen, Jørgen A

    2013-02-01

    Shock absorption is the most important function of the human heel pad. However, changes in heel pad elasticity, as seen in e.g. long-distance runners, diabetes patients, and victims of Falanga torture are affecting this function, often in a painful manner. Assessment of heel pad elasticity is usually based on one or a few strain measurements obtained by an external load-deformation system. The aim of this study was to develop a technique for quantitative measurements of heel pad elastic modulus based on several internal strain measures from within the heel pad by use of ultrasound images. Nine heel phantoms were manufactured featuring a combination of three heel pad stiffnesses and three heel pad thicknesses to model the normal human variation. Each phantom was tested in an indentation system comprising a 7MHz linear array ultrasound transducer, working as the indentor, and a connected load cell. Load-compression data and ultrasound B-mode images were simultaneously acquired in 19 compression steps of 0.1mm each. The internal tissue displacement was for each step calculated by a phase-based cross-correlation technique and internal strain maps were derived from these displacement maps. Elastic moduli were found from the resulting stress-strain curves. The elastic moduli made it possible to distinguish eight of nine phantoms from each other according to the manufactured stiffness and showed very little dependence of the thickness. Mean elastic moduli for the three soft, the three medium, and the three hard phantoms were 89kPa, 153kPa, and 168kPa, respectively. The combination of ultrasound images and force measurements provided an effective way of assessing the elastic properties of the heel pad due to the internal strain estimation. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. iPads at Field Camp: A First Test of the Challenges and Opportunities

    NASA Astrophysics Data System (ADS)

    Hurst, S. D.; Stewart, M. A.

    2011-12-01

    An iPad 2 was given to approximately half of the University of Illinois students attending the Wasatch-Uinta Field Camp (WUFC) in summer 2011. The iPads were provisioned with orientation measuring, mapping and location software. The software would automatically transfer an orientation measurement to the current location on the Google Maps application, and was able to output a full list of orientation data. Students also had normal access to more traditional mapping tools such as Brunton compasses and GPS units and were required to map with these tools along with other students of WUFC not provided iPads. Compared to traditional tools, iPads have drawbacks such as increased weight, break-ability, need for power source and wireless connectivity; in sum, they need a substantial infrastructure that reduces range, availability, and probably most importantly, convenience. Some of these drawbacks inhibited adoption by our students, the primary reasons being the added weight and the inability to map directly to a GIS application with detailed topographic maps equivalent to the physical topographic map sheets used at WUFC. In their favor, the iPads combine a host of tools into one, including software that can measure orientation in a fashion more intuitively than a Brunton. They also allow storage, editing and analysis of data, notes (spoken and/or written) and potentially unlimited access to a variety of maps. Via a post-field camp survey of the University of Illinois students at WUFC, we have identified some of the important issues that need to be addressed before portable tablets like the iPad become the tool of choice for general field work. Some problems are intrinsic to almost any advanced technology, some are artifacts of the current generations of hardware and software available for these devices. Technical drawbacks aside, the adoption of iPads was further inhibited primarily by inexperience with their use as a mapping tool and secondarily by their redundancy with

  19. How does the canine paw pad attenuate ground impacts? A multi-layer cushion system.

    PubMed

    Miao, Huaibin; Fu, Jun; Qian, Zhihui; Ren, Luquan; Ren, Lei

    2017-12-15

    Macroscopic mechanical properties of digitigrade paw pads, such as non-linear elastic and variable stiffness, have been investigated in previous studies; however, little is known about the micro-scale structural characteristics of digitigrade paw pads, or the relationship between these characteristics and the exceptional cushioning of the pads. The digitigrade paw pad consists of a multi-layered structure, which is mainly comprised of a stratified epithelium layer, a dermis layer and a subcutaneous layer. The stratified epithelium layer and dermal papillae constitute the epidermis layer. Finite element analyses were carried out and showed that the epidermis layer effectively attenuated the ground impact across impact velocities of 0.05-0.4 m/s, and that the von Mises stresses were uniformly distributed in this layer. The dermis layer encompassing the subcutaneous layer can be viewed as a hydrostatic system, which can store, release and dissipate impact energy. All three layers in the paw pad work as a whole to meet the biomechanical requirements of animal locomotion. These findings provide insights into the biomechanical functioning of digitigrade paw pads and could be used to facilitate bio-inspired, ground-contacting component development for robots and machines, as well as contribute to footwear design. © 2017. Published by The Company of Biologists Ltd.

  20. Water Quality Survey of Splash Pads After A Waterborne Salmonellosis Outbreak--Tennessee, 2014.

    PubMed

    Clayton, Joshua L; Manners, Judy; Miller, Susan; Shepherd, Craig; Dunn, John R; Schaffner, William; Jones, Timothy F

    2017-06-01

    Waterborne outbreaks of salmonellosis are uncommon. The Tennessee Department of Health investigated a salmonellosis outbreak of 10 cases with the only common risk factor being exposure to a single splash pad. Risks included water splashed in the face at the splash pad and no free residual chlorine in the water system. We surveyed water quality and patron behaviors at splash pads statewide. Of the 29 splash pads participating in the water quality survey, 24 (83%) used a recirculating water system. Of the 24, 5 (21%) water samples were tested by polymerase chain reaction and found to be positive for E. coli, Giardia, norovirus, or Salmonella. Among 95 patrons observed, we identified common high-risk behaviors of sitting on the fountain or spray head and putting mouth to water. Water venue regulations and improved education of patrons are important to aid prevention efforts.

  1. Aerial view of the newest bus stop to view Launch Pad 39B

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Tour buses unload passengers at a new stop on the KSC tour that allows visitors to view Pad LC-39B. The tour road runs parallel to the crawlerway (just out of sight) that is used to transport the Space Shuttle vehicles to the pad. The length of the crawlerway from the Vehicle Assembly Building to Pad B is 6,828 meters (22,440 ft); its width overall is 40 meters (130 ft); each lane is 12 meters (40ft) with a 15-meter (50ft) median. This view looks south.

  2. Effect of Helmet Pads on the Load Transfer to Head under Blast Loadings

    DTIC Science & Technology

    2015-06-01

    0.15 0.2 X  St re ss  (K Pa ) Time (ms) Foam  L Foam  M Foam  R 6 its much smaller acoustic impedance. The stress amplitude increases as it reflects...understood for the helmet/ foam pads. The pads between the helmet and head can not only absorb energy, but also produce more comfort to the head. The gap...to investigate the effects of foam pads on the load transmitted to the head under blast loading. The ALE module in the commercial code, LSDYNA was

  3. Development of a high resolution plantar pressure monitoring pad based on fiber Bragg grating (FBG) sensors.

    PubMed

    Suresh, R; Bhalla, S; Hao, J; Singh, C

    2015-01-01

    High importance is given to plantar pressure monitoring in the field of biomedical engineering for the diagnosis of posture related ailments associated with diseases such as diabetes and gonarthrosis. This paper presents the proof-of-concept development of a new high resolution plantar pressure monitoring pad based on fiber Bragg grating (FBG) sensors. In the proposed configuration, the FBG sensors are embedded within layers of carbon composite material (CCM) in turn conforming to an arc shape. A total of four such arc shaped sensors are instrumented in the pad at the locations of the forefoot and the hind foot. As a test of the pad, static plantar pressure is monitored on normal subjects under various posture conditions. The pad is evaluated both as a standalone platform as well as a pad inserted inside a standard shoe. An average pressure sensitivity of 1.2 pm/kPa and a resolution of approximately 0.8 kPa is obtained in this special configuration. The pad is found to be suitable in both configurations- stand-alone pad as well as an insert inside a standard shoe. The proposed set up offers a cost-effective high resolution and accurate plantar pressure measurement system suitable for clinical deployment. The novelty of the developed pressure pad lies in its ability to be used both as platform type as well as inserted in-sole type sensor system.

  4. Performance evaluation of an evaporative pad greenhouse system for utilization of power plant reject heat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olszewski, M.; Trezek, G.J.

    1976-01-01

    The overall performance of an evaporative pad greenhouse is considered in terms of the pad heat and mass transfer, the energy budget of the vegetation, and the performance of the power plant. An analytical predictive model for the pad performance was developed utilizing the Merkel total heat approximation. Data obtained from actual greenhouse performance provides an experimental verification of the pad model. Energy balance considerations on the vegetation provide a means of viewing optimal plant growth in terms of the power plant energy dissipation. In general, the results indicate that when an evaporative pad greenhouse system is used for wastemore » heat dispersal, the vegetation can be maintained within its thermal requirement zone, crop irrigation requirements are significantly reduced, and the power plant performance is comparable with conventional closed loop heat rejection systems.« less

  5. Engaging Primary School Students in Mathematics: Can iPads Make a Difference?

    ERIC Educational Resources Information Center

    Hilton, Annette

    2018-01-01

    Research on the impact of the integration of technologies such as iPads on primary students' attitudes and engagement in mathematics is limited. Further, there have been claims that teachers' pedagogical choices can strongly influence the effectiveness of iPads for engaging students in mathematics. This paper presents an investigation of the…

  6. Using iPads to Teach Communication Skills of Students with Autism.

    PubMed

    Xin, Joy F; Leonard, Deborah A

    2015-12-01

    The purpose of this study was to examine the effects of using an iPad to assist students with autism in learning communication skills. Three, 10 years old learners diagnosed with autism who present little or no functional speech, participated in the study. A multiple baseline design with AB phases across academic and social settings was used. During the baseline, students were given access to an iPad with the SonoFlex speech-generating device application, while no communicative attempts were observed. During the intervention, the students were taught to use the iPad to communicate with their teacher and peers for 6 weeks. With a least-to-most prompting hierarchy, all students increased initiating requests, responding to questions and making social comments in both class and recess settings.

  7. Foam pad of appropriate thickness can improve diagnostic value of foam posturography in detecting postural instability.

    PubMed

    Liu, Bo; Leng, Yangming; Zhou, Renhong; Liu, Jingjing; Liu, Dongdong; Liu, Jia; Zhang, Su-Lin; Kong, Wei-Jia

    2018-04-01

    The present study investigated the effect of foam thickness on postural stability in patients with unilateral vestibular hypofunction (UVH) during foam posturography. Static and foam posturography were performed in 33 patients (UVH group) and 30 healthy subjects (control group) with eyes open (EO) and closed (EC) on firm surface and on 1-5 foam pad(s). Sway velocity (SV) of center of pressure, standing time before falling (STBF) and falls reaction were recorded and analyzed. (1) SVs had an increasing tendency in both groups as the foam pads were added under EO and EC conditions. (2) STBFs, only in UVH group with EC, decreased with foam thickness increasing. (3) Significant differences in SV were found between the control and UVH group with EO (except for standing on firm surface, on 1 and 2 foam pad(s)) and with EC (all surface conditions). (4) Receiver operating characteristic curve analysis showed that the SV could better reflect the difference in postural stability between the two groups while standing on the 4 foam pads with EC. Our study showed that diagnostic value of foam posturography in detecting postural instability might be enhanced by using foam pad of right thickness.

  8. Launch Pad Escape System Design (Human Spaceflight)

    NASA Technical Reports Server (NTRS)

    Maloney, Kelli

    2011-01-01

    A launch pad escape system for human spaceflight is one of those things that everyone hopes they will never need but is critical for every manned space program. Since men were first put into space in the early 1960s, the need for such an Emergency Escape System (EES) has become apparent. The National Aeronautics and Space Administration (NASA) has made use of various types of these EESs over the past 50 years. Early programs, like Mercury and Gemini, did not have an official launch pad escape system. Rather, they relied on a Launch Escape System (LES) of a separate solid rocket motor attached to the manned capsule that could pull the astronauts to safety in the event of an emergency. This could only occur after hatch closure at the launch pad or during the first stage of flight. A version of a LES, now called a Launch Abort System (LAS) is still used today for all manned capsule type launch vehicles. However, this system is very limited in that it can only be used after hatch closure and it is for flight crew only. In addition, the forces necessary for the LES/LAS to get the capsule away from a rocket during the first stage of flight are quite high and can cause injury to the crew. These shortcomings led to the development of a ground based EES for the flight crew and ground support personnel as well. This way, a much less dangerous mode of egress is available for any flight or ground personnel up to a few seconds before launch. The early EESs were fairly simple, gravity-powered systems to use when thing's go bad. And things can go bad very quickly and catastrophically when dealing with a flight vehicle fueled with millions of pounds of hazardous propellant. With this in mind, early EES designers saw such a passive/unpowered system as a must for last minute escapes. This and other design requirements had to be derived for an EES, and this section will take a look at the safety design requirements had to be derived for an EES, and this section will take a look at

  9. The iPad: tablet technology to support nursing and midwifery student learning: an evaluation in practice.

    PubMed

    Brown, Janie; McCrorie, Pamela

    2015-03-01

    This research explored the impact of tablet technology, in the form of Apple iPads, on undergraduate nursing and midwifery students' learning outcomes. In simulated clinical learning environments, first-year nursing students (n = 30) accessed apps and reference materials on iPads. Third-year nursing students (n = 88) referred to clinical guidelines to aid their decision making when problem solving. First-year midwifery students (n = 25) filmed themselves undertaking a skill and then immediately played back the video file. A total of 45 students completed an online questionnaire that allowed for qualitative comments. Students reported finding the use of iPads easy and that iPads provided point-of-care access to resources, ensuring an evidence-based approach to clinical decision making. iPads reportedly improved student efficiency and time management, while improving their ability to provide patient education. Students who used iPads for the purpose of formative self-assessment appreciated the immediate feedback and opportunity to develop clinical skills.

  10. STS-108 Endeavour Launch from Pad 39-B

    NASA Technical Reports Server (NTRS)

    2001-01-01

    STS-108 Endeavour Launch from Pad 39-B KSC-01PD-1788 KENNEDY SPACE CENTER, Fla. -- A pool of water near Launch Pad 39B turns crimson from the reflection of flames at the launch of Space Shuttle Endeavour on mission STS-109. The second attempt in two days, liftoff occurred at 5:19:28 p.m. EST (10:19.28 GMT). Endeavour will dock with the International Space Station on Dec. 7. STS-108 is the final Shuttle mission of 2001and the 107th Shuttle flight overall. It is the 12th flight to the Space Station. Landing of the orbiter at KSC's Shuttle Landing Facility is targeted for 1:05 p.m. EST (6:05 p.m. GMT) Dec. 16.

  11. ATLAS/AGENA - ON PAD - CAPE

    NASA Image and Video Library

    1965-10-25

    S65-57967 (25 Oct. 1965) --- View at Pad 14 during prelaunch operations for the Atlas/Agena. The Agena is mounted atop its Atlas launch vehicle. The Atlas/Agena liftoff was at 10 a.m. (EST) on Oct. 25, 1965. Intended as a rendezvous target vehicle in the Gemini-6 mission, the Agena failed to achieve orbit, and the Oct. 25 Gemini-6 launch was scrubbed. Photo credit: NASA or National Aeronautics and Space Administration

  12. Metastasis: recent discoveries and novel perioperative treatment strategies with particular interest in the hemostatic compound desmopressin.

    PubMed

    Alonso, D F; Ripoll, G V; Garona, J; Iannucci, N B; Gomez, D E

    2011-11-01

    Metastatic disease is responsible for most of cancer lethality. A main obstacle for therapy of advanced cancers is that the outcome of metastasis depends on a complex interplay between malignant and host cells. The perioperative period represents an underutilized window of opportunity for cancer treatment where tumor-host interactions can be modulated, reducing the risk of local recurrences and distant metastases. Blood-saving agents are attractive compounds to be administered during tumor surgery. Desmopressin (DDAVP) is a safe and convenient hemostatic peptide with proved antimetastastic properties in experimental models and veterinary clinical trials. The compound seems to induce a dual angiostatic and antimetastatic effect, breaking the cooperative function of cancer cells and endothelial cells during residual tumor progression. DDAVP is therefore an interesting lead compound to develop novel synthetic peptide analogs with enhanced antitumor properties.

  13. Some space shuttle tile/strain-isolator-pad sinusoidal vibration tests

    NASA Technical Reports Server (NTRS)

    Miserentino, R.; Pinson, L. D.; Leadbetter, S. A.

    1980-01-01

    Vibration tests were performed on the tile/strain-isolator-pad system used as thermal protection for the space shuttle orbiter. Experimental data on normal and in-plane vibration response and damping properties are presented. Three test specimens exhibited shear type motion during failures that occurred in the tile near the tile/strain-isolator-pad bond-line. A dynamic instability is described which has large in-plane motion at a frequency one-half that of the nominal driving frequency. Analysis shows that this phenomenon is a parametric response.

  14. Hemostatic and toxinological diversities in venom of Micrurus tener tener, Micrurus fulvius fulvius and Micrurus isozonus coral snakes.

    PubMed

    Salazar, Ana M; Vivas, Jeilyn; Sánchez, Elda E; Rodríguez-Acosta, Alexis; Ibarra, Carlos; Gil, Amparo; Carvajal, Zoila; Girón, María E; Estrella, Amalid; Navarrete, Luis F; Guerrero, Belsy

    2011-07-01

    The coral snake Micrurus tener tener (Mtt) from the Elapidae family inhabits the southwestern United States and produces severe cases of envenomations. Although the majority of Mtt venom components are neurotoxins and phospholipase A₂s, this study demonstrated, by SDS-PAGE and molecular exclusion chromatography (MEC), that these venoms also contain high-molecular-weight proteins between 50 and 150 kDa that target the hemostatic system. The biological aspects of other Micrurus venoms were also studied, such as the LD₅₀s of Micrurus isozonus (from 0.52 to 0.61 mg/kg). A pool from these venoms presented a LD₅₀ of 0.57 mg/kg, Micrurus f. fulvius (Mff) and Mtt had LD₅₀s of 0.32 and 0.78 mg/kg, respectively. These venoms contained fibrino(geno)lytic activity, they inhibited platelet aggregation, as well as factor Xa and/or plasmin-like activities. M. isozonus venoms from different Venezuelan geographical regions inhibited ADP-induced platelet aggregation (from 50 to 68%). Micrurus tener tener venom from the United States was the most active with a 95.2% inhibitory effect. This venom showed thrombin-like activity on fibrinogen and human plasma. Fractions of Mtt showed fibrino(geno)lytic activity and inhibition on plasmin amidolytic activity. Several fractions degraded the fibrinogen Aα chains, and fractions F2 and F7 completely degraded both fibrinogen Aα and Bβ chains. To our knowledge, this is the first report on thrombin-like and fibrino(geno)lytic activity and plasmin or factor Xa inhibitors described in Micrurus venoms. Further purification and characterization of these Micrurus venom components could be of therapeutic use in the treatment of hemostatic disorders. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Optimal Padding for the Two-Dimensional Fast Fourier Transform

    NASA Technical Reports Server (NTRS)

    Dean, Bruce H.; Aronstein, David L.; Smith, Jeffrey S.

    2011-01-01

    One-dimensional Fast Fourier Transform (FFT) operations work fastest on grids whose size is divisible by a power of two. Because of this, padding grids (that are not already sized to a power of two) so that their size is the next highest power of two can speed up operations. While this works well for one-dimensional grids, it does not work well for two-dimensional grids. For a two-dimensional grid, there are certain pad sizes that work better than others. Therefore, the need exists to generalize a strategy for determining optimal pad sizes. There are three steps in the FFT algorithm. The first is to perform a one-dimensional transform on each row in the grid. The second step is to transpose the resulting matrix. The third step is to perform a one-dimensional transform on each row in the resulting grid. Steps one and three both benefit from padding the row to the next highest power of two, but the second step needs a novel approach. An algorithm was developed that struck a balance between optimizing the grid pad size with prime factors that are small (which are optimal for one-dimensional operations), and with prime factors that are large (which are optimal for two-dimensional operations). This algorithm optimizes based on average run times, and is not fine-tuned for any specific application. It increases the amount of times that processor-requested data is found in the set-associative processor cache. Cache retrievals are 4-10 times faster than conventional memory retrievals. The tested implementation of the algorithm resulted in faster execution times on all platforms tested, but with varying sized grids. This is because various computer architectures process commands differently. The test grid was 512 512. Using a 540 540 grid on a Pentium V processor, the code ran 30 percent faster. On a PowerPC, a 256x256 grid worked best. A Core2Duo computer preferred either a 1040x1040 (15 percent faster) or a 1008x1008 (30 percent faster) grid. There are many industries that

  16. Brief Report: Using iPads for Self-Monitoring of Students with Autism

    ERIC Educational Resources Information Center

    Xin, Joy F.; Sheppard, Mary E.; Brown, Michelle

    2017-01-01

    This study examined the effect of using an iPad for students with autism spectrum disorder (ASD) on self-monitoring their behaviors in class. Four students with ASD were taught on-task behaviors by watching self-modeled video saved in the application "Choiceworks" on their iPads, and collected data on their own behaviors. A single…

  17. Using iPads as a Data Collection Tool in Extension Programming Evaluation

    ERIC Educational Resources Information Center

    Rowntree, J. E.; Witman, R. R.; Lindquist, G. L.; Raven, M. R.

    2013-01-01

    Program evaluation is an important part of Extension, especially with the increased emphasis on metrics and accountability. Agents are often the point persons for evaluation data collection, and Web-based surveys are a commonly used tool. The iPad tablet with Internet access has the potential to be an effective survey tool. iPads were field tested…

  18. iPads in K-12 Schools: A Grounded Theory Study of Value

    ERIC Educational Resources Information Center

    Townsend, Mary Beth

    2017-01-01

    This qualitative grounded theory study investigated the value of iPads in K-12 schools when used in one-to-one ratios. The purpose of the study was to understand the perspectives of teachers using iPads in one-to-one ratios for teaching and learning in the classroom and administrators responsible for the implementation of these devices. The…

  19. Structure Topology Optimization of Brake Pad in Large- megawatt Wind Turbine Brake Considering Thermal- structural Coupling

    NASA Astrophysics Data System (ADS)

    Zhang, S. F.; Yin, J.; Liu, Y.; Sha, Z. H.; Ma, F. J.

    2016-11-01

    There always exists severe non-uniform wear of brake pad in large-megawatt wind turbine brake during the braking process, which has the brake pad worn out in advance and even threats the safety production of wind turbine. The root cause of this phenomenon is the non-uniform deformation caused by thermal-structural coupling effect between brake pad and disc while braking under the conditions of both high speed and heavy load. For this problem, mathematical model of thermal-structural coupling analysis is built. Based on the topology optimization method of Solid Isotropic Microstructures with Penalization, SIMP, structure topology optimization of brake pad is developed considering the deformation caused by thermal-structural coupling effect. The objective function is the minimum flexibility, and the structure topology optimization model of brake pad is established after indirect thermal- structural coupling analysis. Compared with the optimization result considering non-thermal- structural coupling, the conspicuous influence of thermal effect on brake pad wear and deformation is proven as well as the rationality of taking thermal-structural coupling effect as optimization condition. Reconstructed model is built according to the result, meanwhile analysis for verification is carried out with the same working condition. This study provides theoretical foundation for the design of high-speed and heavy-load brake pad. The new structure may provide design reference for improving the stress condition between brake pad and disc, enhancing the use ratio of friction material and increasing the working performance of large-megawatt wind turbine brake.

  20. 21 CFR 884.5435 - Unscented menstrual pad.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Unscented menstrual pad. 884.5435 Section 884.5435 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices...

  1. 21 CFR 884.5435 - Unscented menstrual pad.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Unscented menstrual pad. 884.5435 Section 884.5435 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices...

  2. 21 CFR 884.5435 - Unscented menstrual pad.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Unscented menstrual pad. 884.5435 Section 884.5435 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices...

  3. 21 CFR 884.5435 - Unscented menstrual pad.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Unscented menstrual pad. 884.5435 Section 884.5435 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices...

  4. Measurement of functional heel pad behaviour in-shoe during gait using orthotic embedded ultrasonography.

    PubMed

    Telfer, Scott; Woodburn, James; Turner, Deborah E

    2014-01-01

    The ability to measure the functional behaviour of the plantar heel pad is clinically relevant in dystrophic or pathological heel conditions and may help to inform the design and development of interventions that attempt to restore normal function. In this study we present a novel technique which utilises orthotic heel inserts with an embedded ultrasound (US) transducer to allow the functional, dynamic behaviour of the heel pad to be measured in-shoe during gait. The aim of this study was to demonstrate feasibility of the technique, determine the reproducibility of measurements, and to compare the effects of two orthotic inserts: (i) a flat orthotic heel raise and (ii) a contoured heel cup insert on the behaviour of the heel pad during gait. Dynamic compression of the heel pads of 16 healthy participants was recorded during treadmill walking and combined with plantar pressure measurements to allow stiffness and energy disappation ratio (EDR) to be estimated. Inter-session reliability of the US measurements was found to be excellent (ICC2,1=0.94-0.95), as was inter-rater reliability (ICC2,1=0.89). Use of the heel cup insert significantly reduced the maximum compression of the heel pad (p<0.0001) as well as the overall stiffness of the pad (p<0.001). There was no change in EDR (p=0.949). In-shoe embedded US is a reliable method to establish person-specific functional geometry of plantar soft tissues. Use of a contoured heel cup reduces the compression of the mid portion of the heel pad. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Compression Pad Cavity Heating Augmentation on Orion Heat Shield

    NASA Technical Reports Server (NTRS)

    Hollis, Brian R.

    2011-01-01

    An experimental study has been conducted to assess the effects of compression pad cavities on the aeroheating environment of the Project Orion Crew Exploration Vehicle heat shield. Testing was conducted in Mach 6 and 10 perfect-gas wind tunnels to obtain heating measurements in and around the compression pads cavities using global phosphor thermography. Data were obtained over a wide range of Reynolds numbers that produced laminar, transitional, and turbulent flow within and downstream of the cavities. The effects of cavity dimensions on boundary-layer transition and heating augmentation levels were studied. Correlations were developed for transition onset and for the average cavity-heating augmentation.

  6. HPAEC-PAD for oligosaccharide analysis-novel insights into analyte sensitivity and response stability.

    PubMed

    Mechelke, Matthias; Herlet, Jonathan; Benz, J Philipp; Schwarz, Wolfgang H; Zverlov, Vladimir V; Liebl, Wolfgang; Kornberger, Petra

    2017-12-01

    The rising importance of accurately detecting oligosaccharides in biomass hydrolyzates or as ingredients in food, such as in beverages and infant milk products, demands for the availability of tools to sensitively analyze the broad range of available oligosaccharides. Over the last decades, HPAEC-PAD has been developed into one of the major technologies for this task and represents a popular alternative to state-of-the-art LC-MS oligosaccharide analysis. This work presents the first comprehensive study which gives an overview of the separation of 38 analytes as well as enzymatic hydrolyzates of six different polysaccharides focusing on oligosaccharides. The high sensitivity of the PAD comes at cost of its stability due to recession of the gold electrode. By an in-depth analysis of the sensitivity drop over time for 35 analytes, including xylo- (XOS), arabinoxylo- (AXOS), laminari- (LOS), manno- (MOS), glucomanno- (GMOS), and cellooligosaccharides (COS), we developed an analyte-specific one-phase decay model for this effect over time. Using this model resulted in significantly improved data normalization when using an internal standard. Our results thereby allow a quantification approach which takes the inevitable and analyte-specific PAD response drop into account. Graphical abstract HPAEC-PAD analysis of oligosaccharides and determination of PAD response drop leading to an improved data normalization.

  7. Multidisciplinary Testing of Floor Pads on Stability, Energy Absorption, and Ease of Hospital Use for Enhanced Patient Safety.

    PubMed

    Crane, Barbara; Goodworth, Adam D; Liquori, Melissa; Ghosh, Suhash; Certo, Catherine; McCafferty, Lorraine

    2016-09-01

    A major improvement in hospital safety could be realized if serious injury did not accompany falls. We studied several commercially available floor pads made of different materials to determine which (if any) would be practical in a hospital room and reduce injury without posing a threat to the balance of patients. A multidisciplinary approach was undertaken to (1) measure upper and lower body motion in 17 young (<50 years) and 17 older (>55 years) adults during an instrumented sit to stand test from a hospital bed onto the different floor pads, (2) predict the energy dissipation available in floor pads by quantifying the relative mechanical properties, and (3) obtain professional feedback from hospital nurses via a questionnaire (8 questions) following a period of working on the different floor pads. Five floor pads, composed of foam, gel, and/or rubber were tested. All pads were compared with a typical hospital floor (concrete covered with linoleum tiles, considered the control). All of the pads subject to mechanical testing showed at least 3 times more energy absorption compared with the control. Balance testing showed that three of the pads resulted in minimal or no significant increases in body motion during sit-to-stand. Nursing feedback revealed that only 2 of these 3 pads may be feasible for hospital room use: one made primarily of firm rubber and one made of foam. Floor pads do exist that show promise for hospital use that absorbing energy without major impacts on balance during sit-to-stand. Although only commercially available pads were investigated, results may inform the design and multidisciplinary testing of other floor surfaces.

  8. Discovery on Pad 39a

    NASA Image and Video Library

    2010-10-31

    The space shuttle Discovery is seen on launch pad 39a early in the morning of Sunday, Oct. 31, 2010 at the NASA Kennedy Space Center in Cape Canaveral, Fla. During Space Shuttle Discovery's final spaceflight, the STS-133 crew members will take important spare parts to the International Space Station along with the Express Logistics Carrier-4. Discovery is targeted for launch at 3:52 p.m. Wednesday, Nov. 3, 2010. Photo Credit: (NASA/Bill Ingalls)

  9. ImagePAD, a Novel Counting Application for the Apple iPad®, Used to Quantify Axons in the Mouse Optic Nerve

    PubMed Central

    Templeton, Justin P.; Struebing, Felix L.; Lemmon, Andrew; Geisert, Eldon E.

    2014-01-01

    The present article introduces a new and easy to use counting application for the Apple iPad. The application “ImagePAD” takes advantage of the advanced user interface features offered by the Apple iOS® platform, simplifying the rather tedious task of quantifying features in anatomical studies. For example, the image under analysis can be easily panned and zoomed using iOS-supported multi-touch gestures without losing the spatial context of the counting task, which is extremely important for ensuring count accuracy. This application allows one to quantify up to 5 different types of objects in a single field and output the data in a tab-delimited format for subsequent analysis. We describe two examples of the use of the application: quantifying axons in the optic nerve of the C57BL/6J mouse and determining the percentage of cells labeled with NeuN or ChAT in the retinal ganglion cell layer. For the optic nerve, contiguous images at 60× magnification were taken and transferred onto an Apple iPad®. Axons were counted by tapping on the touch-sensitive screen using ImagePAD. Nine optic nerves were sampled and the number of axons in the nerves ranged from 38872 axons to 50196 axons with an average of 44846 axons per nerve (SD = 3980 axons). PMID:25281829

  10. Momument at Pad 14 honoring Project Mercury

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Momument at Pad 14 honoring Project Mercury. The Arabic number 7 represents the seven original astronauts. The other figure is the astronomical symbol of the Planet Mercury. In background is the Gemini 12 Agena Target Docking Vehicle atop its Atlas launch vehicle at Cape Kennedy, Florida.

  11. Using an eTextbook and iPad: Results of a Pilot Program

    ERIC Educational Resources Information Center

    Sloan, Roberta H.

    2013-01-01

    An eTextbook and iPad were used in a pilot program, and the impact on the course was assessed to guide the development of a college policy. Students in the course completed three questionnaires to provide feedback about their perceptions of the eTextbook and iPad. During the pilot program, students' perceptions of the usefulness, ease of use, and…

  12. Using iPad-Based Mobile Learning to Teach Creative Engineering within a Problem-Based Learning Pedagogy

    ERIC Educational Resources Information Center

    Li, Yulong; Wang, Lixun

    2018-01-01

    This case study, noting the increasing interest in iPad-based mobile learning research and aware of the current dearth of engineering talent in the UK, aims to contribute to a still sparse area of research that links iPad use to engineering education. To achieve this, the study investigates the integration of iPad-based mobile learning…

  13. iPads and LCDs show similar performance in the detection of pulmonary nodules

    NASA Astrophysics Data System (ADS)

    McEntee, Mark F.; Lowe, Joanna; Butler, Marie Louise; Pietrzyk, Mariusz; Evanoff, Michael G.; Ryan, John; Brennan, Patrick C.; Rainford, Louise A.

    2012-02-01

    In February 2011 the University of Chicago Medical School distributed iPads to its trainee doctors for use when reviewing clinical information and images on the ward or clinics. The use of tablet computing devices is becoming widespread in medicine with Apple™ heralding them as "revolutionary" in medicine. The question arises, just because it is technical achievable to use iPads for clinical evaluation of images, should we do so? The current work assesses the diagnostic efficacy of iPads when compared with LCD secondary display monitors for identifying lung nodules on chest x-rays. Eight examining radiologists of the American Board of Radiology were involved in the assessment, reading chest images on both the iPad and the an off-the-shelf LCD monitor. Thirty chest images were shown to each observer, of which 15 had one or more lung nodules. Radiologists were asked to locate the nodules and score how confident they were with their decision on a scale of 1-5. An ROC and JAFROC analysis was performed and modalities were compared using DBM MRMC. The results demonstrate no significant differences in performance between the iPad and the LCD for the ROC AUC (p<0.075) or JAFROC FOM (p<0.059) for random readers and random cases. Sample size estimation showed that this result is significant at a power of 0.8 and an effect size of 0.05 for ROC and 0.07 for JAFROC. This work demonstrates that for the task of identifying pulmonary nodules, the use of the iPad does not significantly change performance compared to an off-the-shelf LCD.

  14. Stiffness evaluation of neoprene bearing pads under long-term loads : final report, March 2009.

    DOT National Transportation Integrated Search

    2009-03-01

    The objective of this project was to evaluate the interaction between the shear modulus of steel reinforced neoprene bearing pads and shear strain rate. The following interactions related to variations in the shear modulus were investigated for pads ...

  15. Teaching, Learning, and Living with iPads

    ERIC Educational Resources Information Center

    Riley, Patricia

    2013-01-01

    Tablet computers, engaging and dynamic teaching and learning tools, are increasingly prevalent in K-12 schools and university settings. To help music educators make informed technology choices for their classrooms, this article contains preservice teachers' reflections on how they used iPads to enhance their musicianship, teacher preparation,…

  16. 21 CFR 890.5740 - Powered heating pad.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Powered heating pad. 890.5740 Section 890.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5740 Powered heating...

  17. 21 CFR 890.5740 - Powered heating pad.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Powered heating pad. 890.5740 Section 890.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5740 Powered heating...

  18. 21 CFR 890.5740 - Powered heating pad.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Powered heating pad. 890.5740 Section 890.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5740 Powered heating...

  19. 21 CFR 890.5740 - Powered heating pad.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Powered heating pad. 890.5740 Section 890.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5740 Powered heating...

  20. 21 CFR 890.5740 - Powered heating pad.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered heating pad. 890.5740 Section 890.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5740 Powered heating...

  1. 21 CFR 884.5435 - Unscented menstrual pad.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... those with added antimicrobial agents or other drugs. (b) Classification. Class I (general controls... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Unscented menstrual pad. 884.5435 Section 884.5435 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...

  2. Integrating the iPad into an intensive, comprehensive aphasia program.

    PubMed

    Hoover, Elizabeth L; Carney, Anne

    2014-02-01

    The proliferation of tablet technology and the development of apps to support aphasia rehabilitation offer increasing opportunities for speech-language pathologists in a clinical setting. This article describes the components of an Intensive Comprehensive Aphasia Program at Boston University and details how usage of the iPad (Apple Inc., Cupertino, CA) was incorporated. We describe how the iPad was customized for use in individual, dyadic, and group treatment formats and how its use was encouraged through home practice tasks. In addition to providing the participants with step-by-step instructions for the usage of each new app, participants had multiple opportunities for practice across various treatment formats. Examples of how the participants continued using their iPad beyond the program suggest how the usage of this device has generalized into their day-to-day life. An overall summary of performance on targeted linguistic measures as well as an analysis of functional and quality-of-life measures reveal statistically significant improvements pre- to posttreatment. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Non-Linear Vibroisolation Pads Design, Numerical FEM Analysis and Introductory Experimental Investigations

    NASA Astrophysics Data System (ADS)

    Zielnica, J.; Ziółkowski, A.; Cempel, C.

    2003-03-01

    Design and theoretical and experimental investigation of vibroisolation pads with non-linear static and dynamic responses is the objective of the paper. The analytical investigations are based on non-linear finite element analysis where the load-deflection response is traced against the shape and material properties of the analysed model of the vibroisolation pad. A new model of vibroisolation pad of antisymmetrical type was designed and analysed by the finite element method based on the second-order theory (large displacements and strains) with the assumption of material's non-linearities (Mooney-Rivlin model). Stability loss phenomenon was used in the design of the vibroisolators, and it was proved that it would be possible to design a model of vibroisolator in the form of a continuous pad with non-linear static and dynamic response, typical to vibroisolation purposes. The materials used for the vibroisolator are those of rubber, elastomers, and similar ones. The results of theoretical investigations were examined experimentally. A series of models made of soft rubber were designed for the test purposes. The experimental investigations of the vibroisolation models, under static and dynamic loads, confirmed the results of the FEM analysis.

  4. iTeachSTEM: Technological Edgework in High School Teachers' iPad Adoption

    ERIC Educational Resources Information Center

    Hughes, Joan E.; Ko, Yujung; Boklage, Audrey

    2017-01-01

    Few studies of iPad-supported teaching have been set in secondary school STEM contexts, and there is limited examination of teacher practice. This study examined how STEM teachers' pedagogical practices took shape when participating in a secondary-level innovation to use iPads to support critical thinking, collaboration, creativity, and…

  5. 49 CFR 393.47 - Brake actuators, slack adjusters, linings/pads and drums/rotors.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Brake actuators, slack adjusters, linings/pads and..., slack adjusters, linings/pads and drums/rotors. (a) General requirements. Brake components must be... same size. (c) Slack adjusters. The effective length of the slack adjuster on each end of an axle must...

  6. Efficient numerical simulation of an electrothermal de-icer pad

    NASA Technical Reports Server (NTRS)

    Roelke, R. J.; Keith, T. G., Jr.; De Witt, K. J.; Wright, W. B.

    1987-01-01

    In this paper, a new approach to calculate the transient thermal behavior of an iced electrothermal de-icer pad was developed. The method of splines was used to obtain the temperature distribution within the layered pad. Splines were used in order to create a tridiagonal system of equations that could be directly solved by Gauss elimination. The Stefan problem was solved using the enthalpy method along with a recent implicit technique. Only one to three iterations were needed to locate the melt front during any time step. Computational times were shown to be greatly reduced over those of an existing one dimensional procedure without any reduction in accuracy; the curent technique was more than 10 times faster.

  7. The effects of padded surfaces on the risk for cervical spine injury.

    PubMed

    Nightingale, R W; Richardson, W J; Myers, B S

    1997-10-15

    This is an in vitro study comparing cervical spine injuries produced in rigid head impacts and in padded head impacts. To test the hypothesis that deformable impact surfaces pose a greater risk for cervical spine injury than rigid surfaces using a cadaver-based model that includes the effects of the head and torso masses. It is widely assumed that energy-absorbing devices that protect the head from injury also reduce the risk for neck injury. However, this has not been demonstrated in any experimental or epidemiologic study. On the contrary, some studies have shown that padded surfaces have no effect on neck injury risk, and others have suggested that they can increase risk. Experiments were performed on 18 cadaveric cervical spines to test 6 combinations of impact angle and impact surface padding. The impact surface was oriented at -15 degrees (posterior impact), 0 degree (vertex impact), or +15 degrees (anterior impact). The impact surface was either a 3-mm sheet of lubricated Teflon or 5 cm of polyurethane foam. Impacts onto padded surfaces produced significantly larger neck impulses (P = 0.00023) and a significantly greater frequency of cervical spine injuries than rigid impacts (P = 0.0375). The impact angle was also correlated with injury risk (P < 0.00001). These experiments suggest that highly deformable, padded contact surfaces should be used carefully in environments where there is the risk for cervical spine injury. The results also suggest that the orientation of the head, neck, and torso relative to the impact surface is of equal if not greater importance in neck injury risk.

  8. An Exploratory Study of Skin Problems Experienced by UK Nursing Home Residents Using Different Pad Designs.

    PubMed

    Clarke-OʼNeill, Sinead; Farbrot, Anne; Lagerstedt, Marie-Louise; Cottenden, Alan; Fader, Mandy

    2015-01-01

    The primary aim of this study was to determine whether the severity of incontinence-associated dermatitis (IAD) among nursing home-based incontinence pad users varies between pad designs. A second aim was to examine the utility of a simple method for reporting skin health problems in which healthcare assistants were asked to record basic observational data at each pad change. Randomized, multiple crossover, observational, exploratory. Twenty-one men and 57 women using absorbent continence products to contain urinary and/or fecal incontinence were recruited from 10 nursing homes in London and the south of England. A day-time variant and a night-time variant of each of the 4 main disposable pad designs on the market for moderate/heavy incontinence were tested: (1) insert pads with stretch pants; (2) 1-piece all-in-one diapers; (3) pull-up pants; and (4) belted/T-shape diapers. All pad variants for day-time use had an absorption capacity of 1900 mL ± 20% (measured using ISO 11948-1 International Standards Organization) while the capacity of night-time variants was 2400 mL ± 20%. Each resident used each of the 4 pad designs (day-time and night-time variants) for 2 weeks and the order of testing was randomized by nursing home. Skin health data were collected using 2 methods in parallel. Method 1 comprised visual observation by researchers (1 observation per pad design; 4 observations in total over 8 weeks). In method 2, healthcare assistants logged observational data on skin health at every pad change for the 8 weeks. The primary outcome variable was severity of the most severe skin problem noted by the researcher for each resident, and for each pad design (method 1). Descriptive data on skin care methods used in the nursing homes were also collected using short questionnaires and researcher observation. No significant differences in the severity or incidence of skin problems were found between observations using the 4 pad designs. However, a wide range of skin

  9. Design charts for arbitrarily pivoted, liquid-lubricated flat-sector-pad thrust bearing

    NASA Technical Reports Server (NTRS)

    Etsion, I.

    1977-01-01

    A flat, sector-shaped geometry for a liquid-lubricated thrust bearing is analyzed considering both the pitch and roll of the pad. Results are presented in design charts that enable a direct approach to the design of point- and line-pivoted, tilting pad bearings. A comparison is made with the Mitchell bearing approximation and it is found that this approximation always overestimates load capacity.

  10. Launch Pad Coatings for Smart Corrosion Control

    NASA Technical Reports Server (NTRS)

    Calle, Luz M.; Hintze, Paul E.; Bucherl, Cori N.; Li, Wenyan; Buhrow, Jerry W.; Curran, Jerome P.; Whitten, Mary C.

    2010-01-01

    Corrosion is the degradation of a material as a result of its interaction with the environment. The environment at the KSC launch pads has been documented by ASM International (formerly American Society for Metals) as the most corrosive in the US. The 70 tons of highly corrosive hydrochloric acid that are generated by the solid rocket boosters during a launch exacerbate the corrosiveness of the environment at the pads. Numerous failures at the pads are caused by the pitting of stainless steels, rebar corrosion, and the degradation of concrete. Corrosion control of launch pad structures relies on the use of coatings selected from the qualified products list (QPL) of the NASA Standard 5008A for Protective Coating of Carbon Steel, Stainless Steel, and Aluminum on Launch Structures, Facilities, and Ground Support Equipment. This standard was developed to establish uniform engineering practices and methods and to ensure the inclusion of essential criteria in the coating of ground support equipment (GSE) and facilities used by or for NASA. This standard is applicable to GSE and facilities that support space vehicle or payload programs or projects and to critical facilities at all NASA locations worldwide. Environmental regulation changes have dramatically reduced the production, handling, use, and availability of conventional protective coatings for application to KSC launch structures and ground support equipment. Current attrition rate of qualified KSC coatings will drastically limit the number of commercial off the shelf (COTS) products available for the Constellation Program (CxP) ground operations (GO). CxP GO identified corrosion detection and control technologies as a critical, initial capability technology need for ground processing of Ares I and Ares V to meet Constellation Architecture Requirements Document (CARD) CxP 70000 operability requirements for reduced ground processing complexity, streamlined integrated testing, and operations phase affordability

  11. [Response and prognosis of patients with multiple myeloma induced by PAD/TAD].

    PubMed

    Zeng, Tianmei; He, Haiyan; Shi, Haotian; Xi, Hao; Du, Juan; Zhang, Chunyang; Jiang, Hua; Fu, Weijun; Zhou, Fan; Hou, Jian

    2015-03-17

    To evaluate the impact of cytogenetic grouping and autologous stem cell transplantation on the prognosis of patients with multiple myeloma (MM) induced by PAD (velcade+epirubicin+dexamethasone) and TAD (thalidomide+epirubicin+dexamethasone). A total of 191 patients with a definite diagnosis of MM were enrolled from May 2008 to December 2013 into this prospective study. They were non-randomly induced by PAD (n = 132) or TAD (n = 59) plus autologous stem cell transplantation or chemotherapy. Response and survival rates were also analyzed between two groups. The overall response rates of PAD and TAD groups were 84.4% (108/128) and 69.5% (41/59) (P = 0.011) respectively. The very good partial remission (VGPR) rates were 70.3% (90/128) and 32.2% (19/59) (P < 0.001) and near complete remission/complete remission (nCR/CR) rates 68.0% (87/128) and 25.4% (15/59) respectively (P < 0.001). Both progression-free survival (PFS) and overall survival (OS) showed no significant inter-group difference (P = 0.223, 0.989). The survival analysis of PAD group showed that FISH high-risk group had shorter PFS and OS than FISH low-risk group (15.2 vs 19.1 months for PFS, P = 0.098; 41.2 months vs non-attaining for OS, P = 0.017). In FISH high-risk group, patients consolidated with autologous stem cell transplantation showed longer PFS than those with chemotherapy (17.8 vs 14.6 months, P = 0.029) while the OS showed no difference (P = 0.840). In FISH low-risk group, no difference were observed in PFS and OS between patients with consolidation therapies alone (P = 0.131, 0.294). The response rates are higher in patients induced by PAD than by TAD. After PAD induction, cytogenetic grouping may further distinguish the prognosis of MM patients. For FISH high-risk patients, their PFS is prolonged by autologous stem cell transplantation.

  12. STS-26 Discovery, Orbiter Vehicle (OV) 103, at KSC LC pad 39B

    NASA Image and Video Library

    1988-07-04

    S88-42101 (15 July 1988) --- STS-26 Discovery, Orbiter Vehicle (OV) 103, awaits further processing at Kennedy Space Center (KSC) launch complex (LC) pad 39B. OV-103 arrived at LC pad 39B after a six-hour journey from the vehicle assembly building (VAB). The rotating service structure is retracted.

  13. Re-Imagine Your Library with iPads

    ERIC Educational Resources Information Center

    Perez, Lisa

    2013-01-01

    Chicago Public Schools librarians have discovered that iPads engage students in developing their reading, writing, speaking, and listening skills while expressing their creativity. Their librarians embarked on a year-long experiment with the mobile devices that inspired them to completely reinvent the way they teach. This article presents tips…

  14. Predicting the severity of systemic inflammatory response syndrome (SIRS)-associated coagulopathy with hemostatic molecular markers and vascular endothelial injury markers.

    PubMed

    Iba, Toshiaki; Gando, Satoshi; Murata, Atsuo; Kushimoto, Shigeki; Saitoh, Daizoh; Eguchi, Yutaka; Ohtomo, Yasuhiro; Okamoto, Kohji; Koseki, Kazuhide; Mayumi, Toshihiko; Ikeda, Toshiaki; Ishhikura, Hiroyasu; Ueyama, Masashi; Ogura, Yuji; Endo, Shigeatsu; Shimazaki, Shuji

    2007-11-01

    The changes in biomarkers of coagulation or fibrinolysis, anticoagulation, inflammation, and endothelial damage occur in patients with systemic inflammatory response syndrome (SIRS). The purpose of this study is to assess the prognostic value of these markers in patients with SIRS-associated hypercoagulopathy. Sixty-six SIRS patients with a platelet count less than 15.0 x 10(4)/mm3 in three university hospital intensive care units were enrolled in this prospective, comparative study. Blood samples were obtained on day 0 and day 2. Twelve hemostatic, inflammatory, and vascular endothelial indices were measured and the data were compared between the severe group (patients with a total maximum Sequential Organ Failure Assessment score of 10 or more and nonsurvivors; n = 25) and the less-severe group (Sequential Organ Failure Assessment score <10; n = 41). Significant changes between the groups were observed in platelet count, fibrin or fibrinogen degradation products, interleukin-6, soluble thrombomodulin, antithrombin (AT) activity, and protein C activity, both on day 0 and on day 2. In contrast, the d-dimer, soluble fibrin, plasmin-[alpha]2-antiplasmin complex, and E-selectin levels were higher in the severe group only on day 2. No significant difference was seen regarding the thrombin-AT complex and total plasminogen activator inhibitor on both days. A comparison of the areas under the receiver operating characteristic curve revealed the AT activity to be the best predictor of a progression of organ dysfunction. The changes in some hemostatic molecular markers and vascular endothelial markers were conspicuous in patients with organ dysfunction. The AT activity is considered to be the most useful predictor of organ dysfunction.

  15. Reconstruction of the anterior skull base after major trauma or extensive tumour resection.

    PubMed

    König, Stefan Alexander; Ranguis, Sebastian; Gramlich, Veronika; Spetzger, Uwe

    2015-01-01

    The authors describe their experience with the reconstruction of complex anterior skull base defects after trauma or tumour resection using a "sandwich" technique with pericranial flap, titanium mesh and TachoSil. Description of surgical anatomy, surgical technique, indications, limitations, complications, specific perioperative considerations and specific information to give to the patient about surgery and potential risks. A summary of ten key points is given. After a bifrontal craniotomy and a subfrontal approach, it is possible to achieve a reliable reconstruction of the anterior skull base in a watertight manner by fixing a pericranial flap or a fascia lata graft to the orbital roofs and planum sphenoidale with an individually tailored titanium mesh and closing the frontobasal dura leasion with TachoSil.

  16. Heart rate variability, hemostatic and acute inflammatory blood parameters in healthy adults after short-term exposure to welding fume.

    PubMed

    Scharrer, E; Hessel, H; Kronseder, A; Guth, W; Rolinski, B; Jörres, R A; Radon, K; Schierl, R; Angerer, P; Nowak, D

    2007-02-01

    The present study aimed to investigate, whether short-term experimental exposure to high levels of welding fumes would be capable of exerting acute effects in healthy subjects. Specifically, we assessed cardiovascular function in terms of heart rate variability (HRV) as well as the concentrations of inflammatory mediators and hemostatic proteins in blood as outcome measures. Twenty subjects without a history of airway and cardiovascular diseases were exposed to either control air or welding fume for 1 h on 2 separate days under standardized conditions. The median concentration of the alveolar particle fraction during welding was 3.5 mg/m(3 )(quartiles: 1.4-6.3 mg/m(3); range 1.0-25.3 mg/m(3)). Five hours later a panel of clinical assessments was performed, including HRV measurement and drawing of blood samples. There were no changes in symptom ratings or lung function after welding fume exposure. Exposures did also not differ regarding effects on time- and frequency-domain parameters of HRV. Similarly, blood leukocyte numbers, cell differentials and the blood levels of fibrinogen, C-reactive protein, antithrombin III, factor VIII, von Willebrand factor, ristocetin cofactor, sICAM-1, tumor necrosis factor alpha, interleukin 6, interleukin 8 and epithelial neutrophil activating peptide 78 were not altered by welding fume inhalation. However, there was a significant fall in the level of endothelin-1 (P < 0.01). In conclusion, the data did not indicate effects of clinical significance of a short-term high-level exposure to welding fumes on HRV or a set of blood hemostatic and acute inflammatory parameters in healthy subjects. The small but statistically significant effect on endothelin levels demonstrated that measurable effects could be elicited even in these individuals. Overall, welding fumes are not likely to exert acute cardiovascular effects in healthy individuals.

  17. iPad Use for Accelerating Reading Gains in Secondary Students with Learning Disabilities

    ERIC Educational Resources Information Center

    Retter, Shannan; Anderson, Christine; Kieran, Laura

    2013-01-01

    This action research project explored the use of the iPad 2 in a special education classroom with high school students who were considered struggling readers to determine if an academic gain in reading comprehension, reading fluency, and vocabulary implementing the intervention of an iPad and four specific applications (apps). The high school…

  18. Paper-based piezoelectric touch pads with hydrothermally grown zinc oxide nanowires.

    PubMed

    Li, Xiao; Wang, Yu-Hsuan; Zhao, Chen; Liu, Xinyu

    2014-12-24

    This paper describes a new type of paper-based piezoelectric touch pad integrating zinc oxide nanowires (ZnO NWs), which can serve as user interfaces in paper-based electronics. The sensing functionality of these touch pads is enabled by the piezoelectric property of ZnO NWs grown on paper using a simple, cost-efficient hydrothermal method. A piece of ZnO-NW paper with two screen-printed silver electrodes forms a touch button, and touch-induced electric charges from the button are converted into a voltage output using a charge amplifier circuit. A touch pad consisting of an array of buttons can be readily integrated into paper-based electronic devices, allowing user input of information for various purposes such as programming, identification checking, and gaming. This novel design features ease of fabrication, low cost, ultrathin structure, and good compatibility with techniques in printed electronics, and further enriches the available technologies of paper-based electronics.

  19. Foot pad dermatitis develops at an early age in commercial turkeys.

    PubMed

    Mayne, R K; Hocking, P M; Else, R W

    2006-02-01

    1. A field experiment was conducted to identify the macroscopic and histological changes associated with the development of foot pad dermatitis (FPD) in growing turkeys. Two affected and two unaffected turkeys were sampled weekly from 1 to 8 and at 10 and 21 weeks of age. 2. At one week old, birds with external signs of FPD (surface skin discolouration) showed abnormal cellular changes of the foot pad integument. As the flock aged the reactions intensified, with one sample exhibiting a fully developed macroscopic lesion at 3 weeks. 3. Major pathological changes had occurred by 6 weeks and all turkeys with external signs of lesions had fully developed microscopic inflammatory cellular lesions. From 6 weeks of age onwards lesions were increasingly numerous and became more overtly necrotic. 4. Externally normal foot pads showed microscopic evidence of lesions after the turkeys reached 4 weeks. 5. We conclude that FPD lesions become severe over a short period of time and at a very early age.

  20. RCRA, superfund and EPCRA hotline training module. Introduction to: Drip pads (40 cfr parts 264/265, subpart w) updated July 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-07-01

    In 1990, EPA promulgated listings for wastes from wood preserving processes. Many of these wastes are generated by allowing preservative to drip from wood onto concrete pads, called drip pads. To facilitate proper handling of these wastes, EPA developed design and operating standards for drip pads used to manage hazardous wastes. This module explains these standards. It defines a drip pad and summarizes the design and operating standards for drip pads. It describes the relationship between generator accumulation provisions and drip pads.

  1. The iPad as an Instructional Tool: An Examination of Teacher Implementation Experiences

    ERIC Educational Resources Information Center

    Benton, Brandie Kay

    2012-01-01

    At present, handheld devices and tablet computers are infiltrating public schools across the nation, the most popular model being the Apple iPad. Schools and teachers are attempting to integrate the devices and are using a variety of methods and models for implementation. The purpose of this study was to examine the implementation of the iPad as…

  2. Perceptions of Art and Design Faculty on the Instructional Value of iPads

    ERIC Educational Resources Information Center

    Souleles, Nicos; Savva, Stefania; Watters, Hilary; Annesley, Angela

    2017-01-01

    The widespread use of iPads in higher education brings to the forefront questions about the contribution of these computer tablets towards teaching and learning. However, there is a noticeable gap in research on the educational potential of iPads in higher education. This article describes the second stage of a research project on the use of iPads…

  3. Adhesive and robust multilayered poly(lactic acid) nanosheets for hemostatic dressing in liver injury model.

    PubMed

    Komachi, Takuya; Sumiyoshi, Hideaki; Inagaki, Yutaka; Takeoka, Shinji; Nagase, Yu; Okamura, Yosuke

    2017-10-01

    Freestanding biodegradable nanosheets composed of poly(l-lactic acid) (PLLA) have been developed for various biomedical applications. These nanosheets exhibit unique properties such as high adhesiveness and exquisite flexibility; however, they burst easily due to their nanometer thickness. We herein describe a freestanding, multilayered nanosheet composed of PLLA fabricated using a simple combination procedure: (i) multilayering of PLLA and alginate, (ii) gelation of the alginate layers, (iii) fusion-cut sealing, and (iv) elution of the alginate layers. The multilayered nanosheets not only reinforced the bursting strength but also provided a high level of adhesive strength. In fact, they were found to show potential as a hemostatic dressing, and they tended to show reduced tissue adhesion that accompanies liver injury. Therefore, we propose this biomaterial as a candidate for an alternative to conventional therapy in hemorrhage. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1747-1757, 2017. © 2016 Wiley Periodicals, Inc.

  4. The next 10 years in the management of peripheral artery disease: perspectives from the 'PAD 2009' Conference.

    PubMed

    Norgren, L; Hiatt, W R; Dormandy, J A; Hirsch, A T; Jaff, M R; Diehm, C; Baumgartner, I; Belch, J J F

    2010-09-01

    To briefly inform on the conclusions from a conference on the next 10 years in the management of peripheral artery disease (PAD). International participation, invited presentations and open discussion were based on the following issues: Why is PAD under-recognised? Health economic impact of PAD; funding of PAD research; changes of treatment options? Aspects on clinical trials and regulatory views; and the role of guidelines. A relative lack of knowledge about cardiovascular risk and optimal management of PAD patients exists not only among the public, but also in parts of the health-care system. Specialists are required to act for improved information. More specific PAD research is needed for risk management and to apply the best possible evaluation of evidence for treatment strategies. Better strategies for funding are required based on, for example, public/private initiatives. The proportion of endovascular treatments is steadily increasing, more frequently based on observational studies than on randomised controlled trials. The role of guidelines is therefore important to guide the profession in the assessment of most relevant treatment. Copyright 2010 European Society for Vascular Surgery. All rights reserved.

  5. Significance of heel pad confinement for the shock absorption at heel strike.

    PubMed

    Jørgensen, U; Ekstrand, J

    1988-12-01

    Shock absorption (SA) is a simple way to reduce the body load and can be used in the prevention and treatment of injuries. The heel pad is the most important shock absorber in the shoe heel complex. The purpose of this study was to investigate whether the SA at heel strike can be increased by heel support in people and shoes with high or low SA. The impact forces at heel strike were measured on an AMTI (R) force platform. Fourteen legs were tested in seven persons (nine with normal and five with low heel pad SA) in gait analysis and in human drop tests. The tests were performed barefooted, and in a soccer and a running shoe (selected by shoe drop test), with and without the distal 2 cm of the heel counter. The heel pad confinement produced by the heel counter (the heel counter effect) increased the SA in both shoe types significantly in both impact situations. The mean increase in SA was 8.8% (range 5.8%-15.5%). The heel counter effect was in all situations significantly higher in persons with low heel pad shock absorbency (LHPSA) than in those with normal heel pads. The barefoot impact peak force per kg body weight was significantly higher (6% mean) on the side with LHPSA. The running shoe provided the significantly greatest SA compared with the soccer shoe. It is concluded that the shock absorbency at heel strike can be increased significantly by heel support, with highest effect in persons with LHPSA, both in shoes with high and low SA.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Improved CHESS imaging with the use of rice pads: Investigation in the neck, shoulder, and elbow.

    PubMed

    Moriya, Susumu; Miki, Yukio; Yokobayashi, Tsuneo; Yamamoto, Akira; Kanagaki, Mitsunori; Komori, Yoshiaki; Fujimoto, Koji; Ishikawa, Mitsunori

    2010-06-01

    To investigate the feasibility of rice pads for improving nonuniform fat suppression in magnetic resonance imaging (MRI) of the neck, shoulder, and elbow using the chemical shift selective (CHESS) technique. CHESS imaging of the neck, shoulder, and elbow was performed on 10 healthy volunteers with and without the use of rice pads. Images were visually assessed by one radiologist and one radiologic technologist using a four-point scale. Results were compared using Wilcoxon's signed rank sum test. Images with and without rice pads were rated 3.9 and 1.5 for the neck (P = 0.002), 3.85 and 2.5 for the shoulder (P = 0.002), and 3.4 and 2.45 for the elbow (P = 0.004). Fat-suppressed images obtained using the CHESS technique were significantly improved by rice pads for the neck, shoulder, and elbow, indicating that image deterioration with CHESS caused by magnetic field nonuniformity can be improved by rice pads in all body areas.

  7. Pad A Main Flame Deflector Sensor Data and Evaluation

    NASA Technical Reports Server (NTRS)

    Parlier, Christopher R.

    2011-01-01

    Space shuttle launch pads use flame deflectors beneath the vehicle to channel hot gases away from the vehicle. Pad 39 A at the Kennedy Space Center uses a steel structure coated with refractory concrete. The solid rocket booster plume is comprised of gas and molten alumina oxide particles that erodes the refractory concrete. During the beginning of the shuttle program the loads for this system were never validated with a high level of confidence. This paper presents a representation of the instrumentation data collected and follow on materials science evaluation of the materials exposed to the SRB plume. Data collected during STS-133 and STS-134 will be presented that support the evaluation of the components exposed to the SRB plume.

  8. Compressive behavior of laminated neoprene bridge bearing pads under thermal aging condition

    NASA Astrophysics Data System (ADS)

    Jun, Xie; Zhang, Yannian; Shan, Chunhong

    2017-10-01

    The present study was conducted to obtain a better understanding of the variation rule of mechanical properties of laminated neoprene bridge bearing pads under thermal aging condition using compression tests. A total of 5 specimens were processed in a high-temperature chamber. After that, the specimens were tested subjected to axial load. The parameter mainly considered time of thermal aging processing for specimens. The results of compression tests show that the specimens after thermal aging processing are more probably brittle failure than the standard specimen. Moreover, the exposure of steel plate, cracks and other failure phenomena are more serious than the standard specimen. The compressive capacity, ultimate compressive strength, compressive elastic modulus of the laminated neoprene bridge bearing pads decreased dramatically with the increasing in the aging time of thermal aging processing. The attenuation trends of ultimate compressive strength, compressive elastic modulus of laminated neoprene bridge bearing pads under thermal aging condition accord with power function. The attenuation models are acquired by regressing data of experiment with the least square method. The attenuation models conform to reality well which shows that this model is applicable and has vast prospect in assessing the performance of laminated neoprene bridge bearing pads under thermal aging condition.

  9. Study of light transmission through gauze pad effected by blood or liquids to detect needle dislodgement.

    PubMed

    Takeuchi, Akihiro; Ishida, Kai; Morohoshi, Yasuo; Shinbo, Toshihiro; Hirose, Minoru; Ikeda, Noriaki

    2010-02-01

    Serious accidents during hemodialysis such as a large amount of blood loss are often caused by venous needle dislodgement. To develop a bleeding sensor based on a photo sensor for monitoring the needle sites, we studied effects of liquids and porcine blood on light transmission through a thin gauze pad with a basic photo sensor. The photo sensor consisted of an ordinary electrical circuit, a light emitting diode (LED, lambda max = 645 nm), a photo diode (PD), and a thin gauze pad placed between the LED and PD that were tightly attached to the edges of a plastic clip. The light transmitted through the gauze pad, soaked with liquids or porcine blood dropped on it, was measured with a digital voltmeter. The liquids were reverse osmosis water, physiological saline, glucose in water at 5, 10, 20, 40 and 50%, porcine plasma, and porcine blood (Hct 40, 30 and 20%). The liquids on a tight-weave gauze pad, significantly increased the voltage (light transmission) from 0.412 +/- 0.003 V (SD) to 0.794 +/- 0.025 V (minimum, by reverse osmosis water) and to 0.945 +/- 0.011 V (maximum, by 50% glucose). The porcine blood significantly decreased the voltage from 0.412 to 0.195 +/- 0.030 V in Hct 40%, to 0.334 +/- 0.035 in Hct 30%, to 0.397 +/- 0.007 V in Hct 20%. The higher the concentration of glucose, the more the light transmission increased. The higher concentration of Hct, the more the light transmission decreased. Similar results were also shown for the loose-weave pad. Using two types of gauze pads, we confirmed that liquids significantly increased light transmission through gauze pad, but porcine blood decreased light transmission. This opposite response can be used to distinguish liquids from blood on a gauze pad.

  10. 10. Helicopter pad, fire extinguisher at center, looking southwest ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Helicopter pad, fire extinguisher at center, looking southwest - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  11. DNA Multiple Sequence Alignment Guided by Protein Domains: The MSA-PAD 2.0 Method.

    PubMed

    Balech, Bachir; Monaco, Alfonso; Perniola, Michele; Santamaria, Monica; Donvito, Giacinto; Vicario, Saverio; Maggi, Giorgio; Pesole, Graziano

    2018-01-01

    Multiple sequence alignment (MSA) is a fundamental component in many DNA sequence analyses including metagenomics studies and phylogeny inference. When guided by protein profiles, DNA multiple alignments assume a higher precision and robustness. Here we present details of the use of the upgraded version of MSA-PAD (2.0), which is a DNA multiple sequence alignment framework able to align DNA sequences coding for single/multiple protein domains guided by PFAM or user-defined annotations. MSA-PAD has two alignment strategies, called "Gene" and "Genome," accounting for coding domains order and genomic rearrangements, respectively. Novel options were added to the present version, where the MSA can be guided by protein profiles provided by the user. This allows MSA-PAD 2.0 to run faster and to add custom protein profiles sometimes not present in PFAM database according to the user's interest. MSA-PAD 2.0 is currently freely available as a Web application at https://recasgateway.cloud.ba.infn.it/ .

  12. Mechanical evaluation of hip pads to protect against fracture of elderly femurs in falls.

    PubMed

    Tadano, Shigeru; Nakatsuchi, Hiroki; Goto, Naoko; Fujisaki, Kazuhiro; Nakatsuchi, Yukio

    2011-01-01

    Hip fracture in the aged easily occurs by falls and may cause these persons to become bedridden. Hip pads are effective in protecting hip fracture as they directly deflect and absorb the impact forces by falls. It is necessary for the material and the structure of hip pads to be designed to realize both high impact absorption and compliance (comfort during wearing). In this report, an impact testing system was developed to test the impact absorbing performance of hip pad with air cushions designed by the research group. The impact absorbing performance was evaluated by the impact load, collision time, and maximum load. To confirm the effectiveness in protecting against hip fracture, an impact force was applied to the greater trochanter of the human femur and the degree of fracture was measured by X-ray examination. As a result, the hip pad with air cushions had a high impact absorbing performance and was sufficiently effective to protect against hip fracture.

  13. Does padded headgear prevent head injury in rugby union football?

    PubMed

    McIntosh, Andrew S; McCrory, Paul; Finch, Caroline F; Best, John P; Chalmers, David J; Wolfe, Rory

    2009-02-01

    Concussion is a serious problem in many contact sports, including rugby union football. The study's primary aim was to measure the efficacy of padded headgear in reducing the rates of head injury or concussion. A cluster randomized controlled trial with three arms was conducted with rugby union football teams as the unit of randomization. Teams consisted of males participating in under 13-, 15-, 18-, and 20-yr age group competitions. The interventions were "standard" and "modified" padded headgear. Headgear wearing and injury were measured for each study team at each game over two seasons. Eighty-two teams participated in year 1 and 87 in year 2. A total of 1493 participants (10,040 player hours) were in the control group, 1128 participants (8170 player hours) were assigned to the standard headgear group, and 1474 participants (10,650 player hours) were assigned to the modified headgear group. The compliance rates were low in all groups, but 46% of participants wore standard headgear. An intention-to-treat analysis showed no differences in the rates of head injury or concussion between controls and headgear arms. Incidence rate ratios for standard headgear wearers referenced to controls were 0.95 and 1.02 for game and missed game injuries. Analyses of injury rates based on observed wearing patterns also showed no significant differences. Incidence rate ratios for standard headgear wearers referenced to nonwearers were 1.11 and 1.10 for game and missed game injuries. Padded headgear does not reduce the rate of head injury or concussion. The low compliance rates are a limitation. Although individuals may choose to wear padded headgear, the routine or mandatory use of protective headgear cannot be recommended.

  14. Launch Pad 39 Hail Monitor Array System

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Weather conditions at Kennedy Space Center are extremely dynamic, and they greatly affect the safety of the Space Shuttles sitting on the launch pads. For example, on May 13, 1999, the foam on the External Tank (ET) of STS-96 was significantly damaged by hail at the launch pad, requiring rollback to the Vehicle Assembly Building. The loss of ET foam on STS-114 in 2005 intensified interest in monitoring and measuring damage to ET foam, especially from hail. But hail can be difficult to detect and monitor because it is often localized and obscured by heavy rain. Furthermore, the hot Florida climate usually melts the hail even before the rainfall subsides. In response, the hail monitor array (HMA) system, a joint effort of the Applied Physics Laboratory operated by NASA and ASRC Aerospace at KSC, was deployed for operational testing in the fall of 2006. Volunteers from the Community Collaborative Rain, Hail, and Snow (CoCoRaHS) network, in conjunction with Colorado State University, continue to test duplicate hail monitor systems deployed in the high plains of Colorado.

  15. Convergent validity evidence for the Pain and Discomfort Scale (PADS) for pain assessment among adults with intellectual disability

    PubMed Central

    Shinde, Satomi K.; Danov, Stacy; Chen, Chin-Chih; Clary, Jamie; Harper, Vicki; Bodfish, James W.; Symons, Frank J.

    2014-01-01

    Objectives The main aim of the study was to generate initial convergent validity evidence for the Pain and Discomfort Scale (PADS) for use with non-verbal adults with intellectual disabilities (ID). Methods Forty-four adults with intellectual disability (mean age = 46, 52 % male) were evaluated using a standardized sham-controlled and blinded sensory testing protocol, from which FACS and PADS scores were tested for (1) sensitivity to an array of calibrated sensory stimuli, (2) specificity (active vs. sham trials), and (3) concordance. Results The primary findings were that participants were reliably coded using both FACS and PADS approaches as being reactive to the sensory stimuli (FACS: F[2, 86] = 4.71, P < .05, PADS: F[2, 86] = 21.49, P < .05) (sensitivity evidence), not reactive during the sham stimulus trials (FACS: F[1, 43]= 3.77, p = .06, PADS: F[1, 43] = 5.87, p = .02) (specificity evidence), and there were significant (r = .41 – .51, p < .01) correlations between PADS and FACS (convergent validity evidence). Discussion FACS is an objective coding platform for facial expression. It requires intensive training and resources for scoring. As such it may be limited for clinical application. PADS was designed for clinical application. PADS scores were comparable to FACS scores under controlled evaluation conditions providing partial convergent validity evidence for its use. PMID:24135902

  16. Remora fish suction pad attachment is enhanced by spinule friction.

    PubMed

    Beckert, Michael; Flammang, Brooke E; Nadler, Jason H

    2015-11-01

    The remora fishes are capable of adhering to a wide variety of natural and artificial marine substrates using a dorsal suction pad. The pad is made of serial parallel pectinated lamellae, which are homologous to the dorsal fin elements of other fishes. Small tooth-like projections of mineralized tissue from the dorsal pad lamella, known as spinules, are thought to increase the remora's resistance to slippage and thereby enhance friction to maintain attachment to a moving host. In this work, the geometry of the spinules and host topology as determined by micro-computed tomography and confocal microscope data, respectively, are combined in a friction model to estimate the spinule contribution to shear resistance. Model results are validated with natural and artificially created spinules and compared with previous remora pull-off experiments. It was found that spinule geometry plays an essential role in friction enhancement, especially at short spatial wavelengths in the host surface, and that spinule tip geometry is not correlated with lamellar position. Furthermore, comparisons with pull-off experiments suggest that spinules are primarily responsible for friction enhancement on rough host topologies such as shark skin. © 2015. Published by The Company of Biologists Ltd.

  17. Analysis of the March 30, 2011 Hail Event at Shuttle Launch Pad 39A

    NASA Technical Reports Server (NTRS)

    Lane, John E.; Doesken, Nolan J.; Kasparis, Takis C.; Sharp, David W.

    2012-01-01

    The Kennedy Space Center (KSC) Hail Monitor System, a joint effort of the NASA KSC Physics Lab and the KSC Engineering Services Contract (ESC) Applied Technology Lab, was first deployed for operational testing in the fall of 2006. Volunteers from the Community Collaborative Rain, Hail, and Snow Network (CoCoRaHS) in conjunction with Colorado State University have been instrumental in validation testing using duplicate hail monitor systems at sites in the hail prone high plains of Colorado. The KSC Hail Monitor System (HMS), consisting of three stations positioned approximately 500 ft from the launch pad and forming an approximate equilateral triangle, as shown in Figure 1, was first deployed to Pad 39B for support of STS-115. Two months later, the HMS was deployed to Pad 39A for support of STS-116. During support of STS-117 in late February 2007, an unusually intense (for Florida standards) hail event occurred in the immediate vicinity of the exposed space shuttle and launch pad. Hail data of this event was collected by the HMS and analyzed. Support of STS-118 revealed another important application of the hail monitor system. Ground Instrumentation personnel check the hail monitors daily when a vehicle is on the launch pad, with special attention after any storm suspected of containing hail. If no hail is recorded by the HMS, the vehicle and pad inspection team has no need to conduct a thorough inspection of the vehicle immediately following a storm. On the afternoon of July 13, 2007, hail on the ground was reported by observers at the Vertical Assembly Building (VAB) and Launch Control Center (LCC), about three miles west of Pad 39A, as well as at several other locations at KSC. The HMS showed no impact detections, indicating that the shuttle had not been damaged by any of the numerous hail events which occurred on that day.

  18. Volatile organic compounds at two oil and natural gas production well pads in Colorado and Texas using passive samplers.

    PubMed

    Eisele, Adam P; Mukerjee, Shaibal; Smith, Luther A; Thoma, Eben D; Whitaker, Donald A; Oliver, Karen D; Wu, Tai; Colon, Maribel; Alston, Lillian; Cousett, Tamira A; Miller, Michael C; Smith, Donald M; Stallings, Casson

    2016-04-01

    A pilot study was conducted in application of the U.S. Environmental Protection Agency (EPA) Methods 325A/B variant for monitoring volatile organic compounds (VOCs) near two oil and natural gas (ONG) production well pads in the Texas Barnett Shale formation and Colorado Denver-Julesburg Basin (DJB), along with a traffic-dominated site in downtown Denver, CO. As indicated in the EPA method, VOC concentrations were measured for 14-day sampling periods using passive-diffusive tube samplers with Carbopack X sorbent at fenceline perimeter and other locations. VOCs were significantly higher at the DJB well pad versus the Barnett well pad and were likely due to higher production levels at the DJB well pad during the study. Benzene and toluene were significantly higher at the DJB well pad versus downtown Denver. Except for perchloroethylene, VOCs measured at passive sampler locations (PSs) along the perimeter of the Barnett well pad were significantly higher than PSs farther away. At the DJB well pad, most VOC concentrations, except perchloroethylene, were significantly higher prior to operational changes than after these changes were made. Though limited, the results suggest passive samplers are precise (duplicate precision usually ≤10%) and that they can be useful to assess spatial gradients and operational conditions at well pad locations over time-integrated periods. Recently enacted EPA Methods 325A/B use passive-diffusive tube samplers to measure benzene at multiple fenceline locations at petrochemical refineries. This pilot study presents initial data demonstrating the utility of Methods 325A/B for monitoring at ONG facilities. Measurements revealed elevated concentrations reflective of production levels and spatial gradients of VOCs relative to source proximity at the Barnett well pad, as well as operational changes at the DJB well pad. Though limited, these findings indicate that Methods 325A/B can be useful in application to characterize VOCs at well pad

  19. Design of a thermal waist-pad

    NASA Astrophysics Data System (ADS)

    Kursun Bahadir, S.; Sahin, U. K.; Acikgoz Tufan, H.

    2017-10-01

    The objective of the current study is designing a thermal waist-pad for people who have backaches with a sandwich-like multi-layered structure. Two model is developed; one is three-layered and second is five-layered with waterproof woven outer layer fabric, Thermolite® knitted fabric (for five-layered structures), wool knitted, polyester nonwoven fabric, polypropylene nonwoven fabric and viscose nonwoven fabric for mid-layer. 10 different structures are designed and produced. All samples are tested for thermal comfort properties of waist-pad. Multi-layer structures were tested, and according to their thermal performance and thermal comfort criteria, all results are evaluated for identifying the best product. These three factors are examined by analysis of thermal conductivity, thermal resistance, thermal absorptivity, relative water vapour/air permeability, water absorption. Highest thermal resistance test result, 150,42 mK/Wm2, is achieved in five-layered sandwich structure with waterproof fabric, Thermolite® fabric, wool based knitted fabric, Thermolite® fabric and waterproof fabric, respectively. Thermal conductivity result of this structure is 46,2 mW/mK, which is one of the lowest results among the alternative structures. Structures with Thermolite® fabric show higher thermal comfort when compared to others.

  20. 1:1 iPad Implementation: A Study on Efficacy and Achievement in Reading

    ERIC Educational Resources Information Center

    Orman, John Paul

    2017-01-01

    The purpose of this study was to determine 1:1 iPad implementation's impact on students' reading achievement from 2013-2017 and student efficacy in using the technology to learn at one independent middle school in Grades 5-8. To determine the impact of the 1:1 iPad initiative on reading achievement, this mixed methods study examined five years of…