Sample records for tactile adjustable distraction

  1. [An adjustable distractor for transverse maxillary distraction osteogenesis].

    PubMed

    Leyder, P; Wycisk, G; Quilichini, J

    2013-06-01

    The posterior skeletal widening in conventional distractions (Surgical Assisted Rapid Maxillary Expansion) is often modest, in contrast with a predominant anterior expansion. Until recently, it was not possible to consider transverse palatal distraction osteogenesis and Le Fort I impaction or advancement in the same procedure, as the osteosynthesis plates impeded maxillary anterior opening. We developed new sliding osteosynthesis plates allowing to perform an advancement or impaction Le Fort I osteotomy associated with a low-resistance bipartite palatal distraction osteogenesis. We had for aim to describe the device and to determine its clinical applications. This new palatal distractor is made up of two independent stainless steel jacks allowing for an adjustable distraction in the anterior or posterior area as needed. Bone-borne and tooth-borne versions are available. This new distractor can be adjusted sagittally. The distraction can be angular or parallel, and the distraction mode can be modified during post-operative distraction. This device should be adapted to all clinical presentations. It can be used in combination with sliding osteosynthesis to perform a Le Fort 1 osteotomy and at the same time a complete correction of vertical, horizontal, and sagittal deficiencies. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  2. A simple mechanism for measuring and adjusting distraction forces during maxillary advancement.

    PubMed

    Suzuki, Eduardo Yugo; Suzuki, Boonsiva

    2009-10-01

    Direct measurement of distraction forces on the craniofacial skeleton has never been reported. The present report describes the development of a method of assessing and adjusting traction forces applied through maxillary distraction osteogenesis. A simple mechanism to measure and adjust tension force during maxillary distraction osteogenesis was developed and connected bilaterally to the traction screws of a rigid external distraction device. Measurements were carried out before and after activation using a Shimpo (Nidec-Shimpo America Corporation, Itasca, IL) force gauge in 4 patients (2 with unilateral cleft lip and/or palate, 1 with bilateral cleft lip and palate, and 1 with noncleft) during the distraction process. Activation was performed twice a day at a rate of 1 mm/day. The average maximum force applied throughout the distraction period was 42.5 N (range 16.4 to 65.3 N), with increments, after activation, averaging 10.5 N (range 7.9 to 15.7 N). In patients with unilateral cleft lip and/or palate, distraction forces on the larger segment were 65.1% higher than on the lesser segment. A differential pattern of forces was also observed in the patients with asymmetric noncleft. However, the differential forces between lateral segments were not observed in the patient with bilateral cleft lip and palate. During the activation period, distraction forces progressively increased, whereas the amount of maxillary movement decreased. Pain and discomfort were reported with high forces. Through this mechanism, direct measurement and adjustment of distraction forces during maxillary advancement was possible. The unbalanced pattern of forces observed in patients with cleft suggests the necessity of individual adjustments for controlling pain and clinical symptoms. Accordingly, assessment of distraction forces during maxillary distraction osteogenesis is extremely helpful in understanding the biomechanics of the distraction process.

  3. Distracted Biking: An Observational Study.

    PubMed

    Wolfe, Elizabeth Suzanne; Arabian, Sandra Strack; Breeze, Janis L; Salzler, Matthew J

    2016-01-01

    Commuting via bicycle is a very popular mode of transportation in the Northeastern United States. Boston, MA, has seen a rapid increase in bicycle ridership over the past decade, which has raised concerns and awareness about bicycle safety. An emerging topic in this field is distracted bicycle riding. This study was conducted to provide descriptive data on the prevalence and type of distracted bicycling in Boston at different times of day. This was a cross-sectional study in which observers tallied bicyclists at 4 high traffic intersections in Boston during various peak commuting hours for 2 types of distractions: auditory (earbuds/phones in or on ears), and visual/tactile (electronic device or other object in hand). Nineteen hundred seventy-four bicyclists were observed and 615 (31.2%), 95% CI [29, 33%], were distracted. Of those observed, auditory distractions were the most common (N = 349; 17.7%), 95% CI [16, 19], p = .0003, followed by visual/tactile distractions (N = 266; 13.5%), 95% CI [12, 15]. The highest proportion (40.7%), 95% CI [35, 46], of distracted bicyclists was observed during the midday commute (between 13:30 and 15:00). Distracted bicycling is a prevalent safety concern in the city of Boston, as almost a third of all bicyclists exhibited distracted behavior. Education and public awareness campaigns should be designed to decrease distracted bicycling behaviors and promote bicycle safety in Boston. An awareness of the prevalence of distracted biking can be utilized to promote bicycle safety campaigns dedicated to decreasing distracted bicycling and to provide a baseline against which improvements can be measured.

  4. Distracted Biking: An Observational Study

    PubMed Central

    Wolfe, Elizabeth Suzanne; Arabian, Sandra Strack; Breeze, Janis L; Salzler, Matthew J.

    2016-01-01

    Commuting via bicycle is a very popular mode of transportation in the Northeastern United States (US). Boston, MA has seen a rapid increase in bicycle ridership over the past decade which has raised concerns and awareness about bicycle safety. An emerging topic in this field is distracted bicycle riding. This study was conducted to provide descriptive data on the prevalence and type of distracted bicycling in Boston at different times of day. This was a cross-sectional study in which observers tallied bicyclists at four high traffic intersections in Boston during various peak commuting hours for two types of distractions: auditory (ear buds/phones in or on ears), and visual/tactile (electronic device or other object in hand). Nineteen hundred seventy-four bicyclists were observed and 615 (31.2%, 95% CI: 29%-33%) were distracted. Of those observed, auditory distractions were the most common (N= 349 [17.7%, 95% CI: 16%-19%], p=0.0003) followed by visual/tactile distractions (N= 266 [13.5%, 95% CI: 12%-15%]). The highest proportion (40.7%, 95% CI: 35%-46%) of distracted bicyclists was observed during the midday commute (between 13:30-15:00). Distracted bicycling is a prevalent safety concern in the city of Boston, as almost one-third of all bicyclists exhibited distracted behavior. Education and public awareness campaigns should be designed to decrease distracted bicycling behaviors and promote bicycle safety in Boston. An awareness of the prevalence of distracted biking can be utilized to promote bicycle safety campaigns dedicated to decreasing distracted bicycling and to provide a baseline against which improvements can be measured. PMID:26953533

  5. Introduction of a new removable adjustable intraoral maxillary distraction system for correction of maxillary hypoplasia.

    PubMed

    Figueroa, Alvaro A; Polley, John W; Figueroa, Alexander L

    2009-09-01

    Distraction osteogenesis has become a treatment alternative to treat severe craniofacial skeletal dysplasias. A rigid external distraction device has been successfully used to advance the maxilla as well as the maxillary, orbital, and forehead complex (monobloc) in children as young as 2 years, adolescents, and adults. For this severe group of patients, the technique has been found to be simpler and safer than traditional surgical methods. Maxillary and midfacial advancement through distraction has been found to be extremely stable in the patients in whom the technique was used.The authors introduce an intraoral distractor for those patients requiring a moderate maxillary advancement. The advantages of the device include ease of insertion, vector adjustability, reactivation capabilities, and no need for second procedure for its removal.The above approaches have provided predictable and stable results. A detailed description of the device, necessary orthodontic and surgical procedures, case reports, and cephalometric outcomes are presented. The techniques can be applied alone or as an adjunct to traditional orthognathic and craniofacial surgical procedures.

  6. The costly filtering of potential distraction: evidence for a supramodal mechanism.

    PubMed

    Marini, Francesco; Chelazzi, Leonardo; Maravita, Angelo

    2013-08-01

    When dealing with significant sensory stimuli, performance can be hampered by distracting events. Attention mechanisms lessen such negative effects, enabling selection of relevant information while blocking potential distraction. Recent work shows that preparatory brain activity, occurring before a critical stimulus, may reflect mechanisms of attentional control aimed to filter upcoming distracters. However, it is unknown whether the engagement of these filtering mechanisms to counteract distraction in itself taxes cognitive-brain systems, leading to performance costs. Here we address this question and, specifically, seek the behavioral signature of a mechanism for the filtering of potential distraction within and between sensory modalities. We show that, in potentially distracting contexts, a filtering mechanism is engaged to cope with forthcoming distraction, causing a dramatic behavioral cost in no-distracter trials during a speeded tactile discrimination task. We thus demonstrate an impaired processing caused by a potential, yet absent, distracter. This effect generalizes across different sensory modalities, such as vision and audition, and across different manipulations of the context, such as the distracter's sensory modality and pertinence to the task. Moreover, activation of the filtering mechanism relies on both strategic and reactive processes, as shown by its dynamic dependence on probabilistic and cross-trial contingencies. Crucially, across participants, the observed strategic cost is inversely related to the interference exerted by a distracter on distracter-present trials. These results attest to a mechanism for the monitoring and filtering of potential distraction in the human brain. Although its activation is indisputably beneficial when distraction occurs, it leads to robust costs when distraction is actually expected but currently absent. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  7. Integration of tactile input across fingers in a patient with finger agnosia.

    PubMed

    Anema, Helen A; Overvliet, Krista E; Smeets, Jeroen B J; Brenner, Eli; Dijkerman, H Chris

    2011-01-01

    Finger agnosia has been described as an inability to explicitly individuate between the fingers, which is possibly due to fused neural representations of these fingers. Hence, are patients with finger agnosia unable to keep tactile information perceived over several fingers separate? Here, we tested a finger agnosic patient (GO) on two tasks that measured the ability to keep tactile information simultaneously perceived by individual fingers separate. In experiment 1 GO performed a haptic search task, in which a target (the absence of a protruded line) needed to be identified among distracters (protruded lines). The lines were presented simultaneously to the fingertips of both hands. Similarly to the controls, her reaction time decreased when her fingers were aligned as compared to when her fingers were stretched and in an unaligned position. This suggests that she can keep tactile input from different fingers separate. In experiment two, GO was required to judge the position of a target tactile stimulus to the index finger, relatively to a reference tactile stimulus to the middle finger, both in fingers uncrossed and crossed position. GO was able to indicate the relative position of the target stimulus as well as healthy controls, which indicates that she was able to keep tactile information perceived by two neighbouring fingers separate. Interestingly, GO performed better as compared to the healthy controls in the finger crossed condition. Together, these results suggest the GO is able to implicitly distinguish between tactile information perceived by multiple fingers. We therefore conclude that finger agnosia is not caused by minor disruptions of low-level somatosensory processing. These findings further underpin the idea of a selective impaired higher order body representation restricted to the fingers as underlying cause of finger agnosia. Copyright © 2010 Elsevier Ltd. All rights reserved.

  8. Tactile-STAR: A Novel Tactile STimulator And Recorder System for Evaluating and Improving Tactile Perception.

    PubMed

    Ballardini, Giulia; Carlini, Giorgio; Giannoni, Psiche; Scheidt, Robert A; Nisky, Ilana; Casadio, Maura

    2018-01-01

    Many neurological diseases impair the motor and somatosensory systems. While several different technologies are used in clinical practice to assess and improve motor functions, somatosensation is evaluated subjectively with qualitative clinical scales. Treatment of somatosensory deficits has received limited attention. To bridge the gap between the assessment and training of motor vs. somatosensory abilities, we designed, developed, and tested a novel, low-cost, two-component (bimanual) mechatronic system targeting tactile somatosensation: the Tactile-STAR -a tactile stimulator and recorder. The stimulator is an actuated pantograph structure driven by two servomotors, with an end-effector covered by a rubber material that can apply two different types of skin stimulation: brush and stretch. The stimulator has a modular design, and can be used to test the tactile perception in different parts of the body such as the hand, arm, leg, big toe, etc. The recorder is a passive pantograph that can measure hand motion using two potentiometers. The recorder can serve multiple purposes: participants can move its handle to match the direction and amplitude of the tactile stimulator, or they can use it as a master manipulator to control the tactile stimulator as a slave. Our ultimate goal is to assess and affect tactile acuity and somatosensory deficits. To demonstrate the feasibility of our novel system, we tested the Tactile-STAR with 16 healthy individuals and with three stroke survivors using the skin-brush stimulation. We verified that the system enables the mapping of tactile perception on the hand in both populations. We also tested the extent to which 30 min of training in healthy individuals led to an improvement of tactile perception. The results provide a first demonstration of the ability of this new system to characterize tactile perception in healthy individuals, as well as a quantification of the magnitude and pattern of tactile impairment in a small cohort of

  9. The role of driver distraction in crashes: an analysis of 1995-1999 Crashworthiness Data System Data.

    PubMed

    Stutts, J C; Reinfurt, D W; Rodgman, E A

    2001-01-01

    Five years (1995-1999) of national Crashworthiness Data System (CDS) data are analyzed to determine the role of driver distraction in traffic crashes and the specific sources of this distraction. Results show that 8.3 percent of the drivers were distracted at the time of their crash; after adjustment for the large percentage of drivers with unknown distraction status, the percentage rose to 12.9 percent. The most frequently cited sources of driver distraction were persons, objects or events outside the vehicle (29.4% of distracted drivers), adjusting the radio, tape or CD player (11.4%), and other occupants in the vehicle (10.9%). Other specific distractions (moving objects in vehicle, other objects brought into vehicle, adjusting vehicle or climate controls, eating and drinking, cell phones, and smoking) were each cited in only one to four percent of the cases. The likelihood of being distracted and the source of distraction varied by driver age but not by gender. Results are discussed in light of the limitations inherent in the CDS and other crash data, and the need for expanded data collection initiatives.

  10. Tactile discrimination, but not tactile stimulation alone, reduces chronic limb pain.

    PubMed

    Moseley, G Lorimer; Zalucki, Nadia M; Wiech, Katja

    2008-07-31

    Chronic pain is often associated with reduced tactile acuity. A relationship exists between pain intensity, tactile acuity and cortical reorganisation. When pain resolves, tactile function improves and cortical organisation normalises. Tactile acuity can be improved in healthy controls when tactile stimulation is associated with a behavioural objective. We hypothesised that, in patients with chronic limb pain and decreased tactile acuity, discriminating between tactile stimuli would decrease pain and increase tactile acuity, but tactile stimulation alone would not. Thirteen patients with complex regional pain syndrome (CRPS) of one limb underwent a waiting period and then approximately 2 weeks of tactile stimulation under two conditions: stimulation alone or discrimination between stimuli according to their diameter and location. There was no change in pain (100 mm VAS) or two-point discrimination (TPD) during a no-treatment waiting period, nor during the stimulation phase (p > 0.32 for both). Pain and TPD were lower after the discrimination phase [mean (95% CI) effect size for pain VAS = 27 mm (14-40 mm) and for TPD = 5.7 mm (2.9-8. ), p < 0.015 for both]. These gains were maintained at three-month follow-up. We conclude that tactile stimulation can decrease pain and increase tactile acuity when patients are required to discriminate between the type and location of tactile stimuli.

  11. Tactile agnosia. Underlying impairment and implications for normal tactile object recognition.

    PubMed

    Reed, C L; Caselli, R J; Farah, M J

    1996-06-01

    In a series of experimental investigations of a subject with a unilateral impairment of tactile object recognition without impaired tactile sensation, several issues were addressed. First, is tactile agnosia secondary to a general impairment of spatial cognition? On tests of spatial ability, including those directed at the same spatial integration process assumed to be taxed by tactile object recognition, the subject performed well, implying a more specific impairment of high level, modality specific tactile perception. Secondly, within the realm of high level tactile perception, is there a distinction between the ability to derive shape ('what') and spatial ('where') information? Our testing showed an impairment confined to shape perception. Thirdly, what aspects of shape perception are impaired in tactile agnosia? Our results indicate that despite accurate encoding of metric length and normal manual exploration strategies, the ability tactually to perceive objects with the impaired hand, deteriorated as the complexity of shape increased. In addition, asymmetrical performance was not found for other body surfaces (e.g. her feet). Our results suggest that tactile shape perception can be disrupted independent of general spatial ability, tactile spatial ability, manual shape exploration, or even the precise perception of metric length in the tactile modality.

  12. Novel Tactile Sensor Technology and Smart Tactile Sensing Systems: A Review

    PubMed Central

    Ge, Chang; Wang, Z. Jane; Cretu, Edmond; Li, Xiaoou

    2017-01-01

    During the last decades, smart tactile sensing systems based on different sensing techniques have been developed due to their high potential in industry and biomedical engineering. However, smart tactile sensing technologies and systems are still in their infancy, as many technological and system issues remain unresolved and require strong interdisciplinary efforts to address them. This paper provides an overview of smart tactile sensing systems, with a focus on signal processing technologies used to interpret the measured information from tactile sensors and/or sensors for other sensory modalities. The tactile sensing transduction and principles, fabrication and structures are also discussed with their merits and demerits. Finally, the challenges that tactile sensing technology needs to overcome are highlighted. PMID:29149080

  13. Scalable, MEMS-enabled, vibrational tactile actuators for high resolution tactile displays

    NASA Astrophysics Data System (ADS)

    Xie, Xin; Zaitsev, Yuri; Velásquez-García, Luis Fernando; Teller, Seth J.; Livermore, Carol

    2014-12-01

    The design, fabrication, and characterization of a new type of tactile display for people with blindness or low vision is reported. Each tactile element comprises a piezoelectric extensional actuator that vibrates in plane, with a microfabricated scissor mechanism to convert the in-plane actuations into robust, higher-amplitude, out-of-plane (vertical) vibrations that are sensed with the finger pads. When the tactile elements are formed into a 2D array, information can be conveyed to the user by varying the pattern of vibrations in space and time. Analytical models and finite element analysis were used to design individual tactile elements, which were implemented with PZT actuators and both SU-8 and 3D-printed scissor amplifiers. The measured displacements of these 3 mm × 10 mm, MEMS-enabled tactile elements exceed 10 µm, in agreement with models, with measured forces exceeding 45 mN. The performance of the MEMS-enabled tactile elements is compared with the performance of larger, fully-macroscale tactile elements to demonstrate the scale dependence of the devices. The creation of a 28-element prototype is also reported, and the qualitative user experience with the individual tactile elements and displays is described.

  14. An evidence-based review: distracted driver.

    PubMed

    Llerena, Luis E; Aronow, Kathy V; Macleod, Jana; Bard, Michael; Salzman, Steven; Greene, Wendy; Haider, Adil; Schupper, Alex

    2015-01-01

    Cell phone use and texting are prevalent within society and have thus pervaded the driving population. This technology is a growing concern within the confines of distracted driving, as all diversions from attention to the road have been shown to increase the risk of crashes. Adolescent, inexperienced drivers, who have the greatest prevalence of texting while driving, are at a particularly higher risk of crashes because of distraction. Members of the Injury Control Violence Prevention Committee of the Eastern Association for the Surgery of Trauma performed a PubMed search of articles related to distracted driving and cell phone use as a distractor of driving between 2000 and 2013. A total of 19 articles were found to merit inclusion as evidence in the evidence-based review. These articles provided evidence regarding the relationship between distracted driving and crashes, cell phone use contributing to automobile accidents, and/or the relationship between driver experience and automobile accidents. (Adjust methods/results sections to the number of articles that correctly corresponds to the number of references, as well as the methodology for reference inclusion.) Based on the evidence reviewed, we can recommend the following. All drivers should minimize all in-vehicle distractions while on the road. All drivers should not text or use any touch messaging system (including the use of social media sites such as Facebook and Twitter) while driving. Younger, inexperienced drivers should especially not use cell phones, texting, or any touch messaging system while driving because they pose an increased risk for death and injury caused by distractions while driving.

  15. What drives technology-based distractions? A structural equation model on social-psychological factors of technology-based driver distraction engagement.

    PubMed

    Chen, Huei-Yen Winnie; Donmez, Birsen

    2016-06-01

    With the proliferation of new mobile and in-vehicle technologies, understanding the motivations behind a driver's voluntary engagement with such technologies is crucial from a safety perspective, yet is complex. Previous literature either surveyed a large number of distractions that may be diverse, or too focuses on one particular activity, such as cell phone use. Further, earlier studies about social-psychological factors underlying driver distraction tend to focus on one or two factors in-depth, and those that examine a more comprehensive set of factors are often limited in their analyses methods. The present work considers a wide array of social-psychological factors within a structural equation model to predict their influence on a focused set of technology-based distractions. A better understanding of these facilitators can enhance the design of distraction mitigation strategies. We analysed survey responses about three technology-based driver distractions: holding phone conversations, manually interacting with cell phones, and adjusting the settings of in-vehicle technology, as well as responses on five social-psychological factors: attitude, descriptive norm, injunctive norm, technology inclination, and a risk/sensation seeking personality. Using data collected from 525 drivers (ages: 18-80), a structural equation model was built to analyse these social-psychological factors as latent variables influencing self-reported engagement in these three technology-based distractions. Self-reported engagement in technology-based distractions was found to be largely influenced by attitudes about the distractions. Personality and social norms also played a significant role, but technology inclination did not. A closer look at two age groups (18-30 and 30+) showed that the effect of social norms, especially of injunctive norm (i.e., perceived approvals), was less prominent in the 30+ age group, while personality remained a significant predictor for the 30+ age group but

  16. The use of mandibular body distraction in hemifacial microsomia

    PubMed Central

    Sakamoto, Yoshiaki; Nakajima, Hideo; Ogata, Hisao; Kishi, Kazuo

    2013-01-01

    Objective: The goals of treatment for hemifacial microsomia include horizontalization of occlusal plane and acquisition of facial symmetry. Although horizontalization of occlusal plane can be easily achieved, facial symmetry, particularly in relation to mandibular contour, can be difficult to attain. Soft tissue is generally reconstructed to correct facial asymmetry, and no studies have described correction of facial asymmetry through skeletal reconstruction. Case: A 12-year-old girl presented with grade IIb right-sided hemifacial microsomia. She was treated using Nakajima's angle-variable internal distraction (NAVID) system for mandibular body distraction. Results: Following treatment, appropriate facial symmetry was achieved, and the patient was extremely satisfied with the results. Conclusions: Thus, we successfully treated the present patient by our novel method involving distraction osteogenesis. This method was effective and useful for several reasons including; the changes were not accompanied by postoperative tissue absorption, donor sites were not involved, and the treatment outcome could be reevaluated by adjusting distraction while the patient's appearance was being remodeled. PMID:24205479

  17. An overview of tactile sensing

    NASA Technical Reports Server (NTRS)

    Agrawal, Rajeev; Jain, Ramesh

    1986-01-01

    Existing or proposed tactile sensors are reviewed. General considerations involved in tactile sensing and various performance criteria are discussed. Typical specifications to be expected from the sensors are also described. A representative set of present day tactile sensors is studied. Finally, some of the proposed recognition systems using tactile sensing are described.

  18. Tactile Signing with One-Handed Perception

    ERIC Educational Resources Information Center

    Mesch, Johanna

    2013-01-01

    Tactile signing among persons with deaf-blindness is not homogenous; rather, like other forms of language, it exhibits variation, especially in turn taking. Early analyses of tactile Swedish Sign Language, tactile Norwegian Sign Language, and tactile French Sign Language focused on tactile communication with four hands, in which partially blind or…

  19. Why Early Tactile Speech Aids May Have Failed: No Perceptual Integration of Tactile and Auditory Signals.

    PubMed

    Rizza, Aurora; Terekhov, Alexander V; Montone, Guglielmo; Olivetti-Belardinelli, Marta; O'Regan, J Kevin

    2018-01-01

    Tactile speech aids, though extensively studied in the 1980's and 1990's, never became a commercial success. A hypothesis to explain this failure might be that it is difficult to obtain true perceptual integration of a tactile signal with information from auditory speech: exploitation of tactile cues from a tactile aid might require cognitive effort and so prevent speech understanding at the high rates typical of everyday speech. To test this hypothesis, we attempted to create true perceptual integration of tactile with auditory information in what might be considered the simplest situation encountered by a hearing-impaired listener. We created an auditory continuum between the syllables /BA/ and /VA/, and trained participants to associate /BA/ to one tactile stimulus and /VA/ to another tactile stimulus. After training, we tested if auditory discrimination along the continuum between the two syllables could be biased by incongruent tactile stimulation. We found that such a bias occurred only when the tactile stimulus was above, but not when it was below its previously measured tactile discrimination threshold. Such a pattern is compatible with the idea that the effect is due to a cognitive or decisional strategy, rather than to truly perceptual integration. We therefore ran a further study (Experiment 2), where we created a tactile version of the McGurk effect. We extensively trained two Subjects over 6 days to associate four recorded auditory syllables with four corresponding apparent motion tactile patterns. In a subsequent test, we presented stimulation that was either congruent or incongruent with the learnt association, and asked Subjects to report the syllable they perceived. We found no analog to the McGurk effect, suggesting that the tactile stimulation was not being perceptually integrated with the auditory syllable. These findings strengthen our hypothesis according to which tactile aids failed because integration of tactile cues with auditory speech

  20. Why Early Tactile Speech Aids May Have Failed: No Perceptual Integration of Tactile and Auditory Signals

    PubMed Central

    Rizza, Aurora; Terekhov, Alexander V.; Montone, Guglielmo; Olivetti-Belardinelli, Marta; O’Regan, J. Kevin

    2018-01-01

    Tactile speech aids, though extensively studied in the 1980’s and 1990’s, never became a commercial success. A hypothesis to explain this failure might be that it is difficult to obtain true perceptual integration of a tactile signal with information from auditory speech: exploitation of tactile cues from a tactile aid might require cognitive effort and so prevent speech understanding at the high rates typical of everyday speech. To test this hypothesis, we attempted to create true perceptual integration of tactile with auditory information in what might be considered the simplest situation encountered by a hearing-impaired listener. We created an auditory continuum between the syllables /BA/ and /VA/, and trained participants to associate /BA/ to one tactile stimulus and /VA/ to another tactile stimulus. After training, we tested if auditory discrimination along the continuum between the two syllables could be biased by incongruent tactile stimulation. We found that such a bias occurred only when the tactile stimulus was above, but not when it was below its previously measured tactile discrimination threshold. Such a pattern is compatible with the idea that the effect is due to a cognitive or decisional strategy, rather than to truly perceptual integration. We therefore ran a further study (Experiment 2), where we created a tactile version of the McGurk effect. We extensively trained two Subjects over 6 days to associate four recorded auditory syllables with four corresponding apparent motion tactile patterns. In a subsequent test, we presented stimulation that was either congruent or incongruent with the learnt association, and asked Subjects to report the syllable they perceived. We found no analog to the McGurk effect, suggesting that the tactile stimulation was not being perceptually integrated with the auditory syllable. These findings strengthen our hypothesis according to which tactile aids failed because integration of tactile cues with auditory speech

  1. Tactile Evaluation Feedback System for Multi-Layered Structure Inspired by Human Tactile Perception Mechanism.

    PubMed

    Hashim, Iza Husna Mohamad; Kumamoto, Shogo; Takemura, Kenjiro; Maeno, Takashi; Okuda, Shin; Mori, Yukio

    2017-11-11

    Tactile sensation is one type of valuable feedback in evaluating a product. Conventionally, sensory evaluation is used to get direct subjective responses from the consumers, in order to improve the product's quality. However, this method is a time-consuming and costly process. Therefore, this paper proposes a novel tactile evaluation system that can give tactile feedback from a sensor's output. The main concept of this system is hierarchically layering the tactile sensation, which is inspired by the flow of human perception. The tactile sensation is classified from low-order of tactile sensation (LTS) to high-order of tactile sensation (HTS), and also to preference. Here, LTS will be correlated with physical measures. Furthermore, the physical measures that are used to correlate with LTS are selected based on four main aspects of haptic information (roughness, compliance, coldness, and slipperiness), which are perceived through human tactile sensors. By using statistical analysis, the correlation between each hierarchy was obtained, and the preference was derived in terms of physical measures. A verification test was conducted by using unknown samples to determine the reliability of the system. The results showed that the system developed was capable of estimating preference with an accuracy of approximately 80%.

  2. Availability of vision and tactile gating: vision enhances tactile sensitivity.

    PubMed

    Colino, Francisco L; Lee, Ji-Hang; Binsted, Gordon

    2017-01-01

    A multitude of events bombard our sensory systems at every moment of our lives. Thus, it is important for the sensory and motor cortices to gate unimportant events. Tactile suppression is a well-known phenomenon defined as a reduced ability to detect tactile events on the skin before and during movement. Previous experiments (Buckingham et al. in Exp Brain Res 201(3):411-419, 2010; Colino et al. in Physiol Rep 2(3):e00267, 2014) found detection rates decrease just prior to and during finger abduction and decrease according to the proximity of the moving effector. However, what effect does vision have on tactile gating? There is ample evidence (see Serino and Haggard in Neurosci Biobehav Rev 34:224-236, 2010) observing increased tactile acuity when participants see their limbs. The present study examined how tactile detection changes in response to visual condition (vision/no vision). Ten human participants used their right hand to reach and grasp a cylinder. Tactors were attached to the index finger and the forearm of both the right and left arm and vibrated at various epochs relative to a "go" tone. Results replicate previous findings from our laboratory (Colino et al. in Physiol Rep 2(3):e00267, 2014). Also, tactile acuity decreased when participants did not have vision. These results indicate that the vision affects the somatosensation via inputs from parietal areas (Konen and Haggard in Cereb Cortex 24(2):501-507, 2014) but does so in a reach-to-grasp context.

  3. Simultaneous maxillary distraction osteogenesis using a twin-track distraction device combined with alveolar bone grafting in cleft patients: preliminary report of a technique.

    PubMed

    Suzuki, Eduardo Yugo; Watanabe, Masayo; Buranastidporn, Boonsiva; Baba, Yoshiyuki; Ohyama, Kimie; Ishii, Masatoshi

    2006-01-01

    The simultaneous use of cleft reduction and maxillary advancement by distraction osteogenesis has not been applied routinely because of the difficulty in three-dimensional control and stabilization of the transported segments. This report describes a new approach of simultaneous bilateral alveolar cleft reduction and maxillary advancement by distraction osteogenesis combined with autogenous bone grafting. A custom-made Twin-Track device was used to allow bilateral alveolar cleft closure combined with simultaneous maxillary advancement, using distraction osteogenesis and a rigid external distraction system in a bilateral cleft lip and palate patient. After a maxillary Le Fort I osteotomy, autogenous iliac bone graft was placed in the cleft spaces before suturing. A latency period of six days was observed before activation. The rate of activation was one mm/d for the maxillary advancement and 0.5 mm/d for the segmental transport. Accordingly, the concave facial appearance was improved with acceptable occlusion, and complete bilateral cleft closure was attained. No adjustments were necessary to the vector of the transported segments during the activation and no complications were observed. The proposed Twin-Track device, based on the concept of track-guided bone transport, permitted three-dimensional control over the distraction processes allowing simultaneous cleft closure, maxillary distraction, and autogenous bone grafting. The combined simultaneous approach is extremely advantageous in correcting severe deformities, reducing the number of surgical interventions and, consequently, the total treatment time.

  4. Electroencephalographic study showing that tactile stimulation by fabrics of different qualities elicit graded event-related potentials.

    PubMed

    Hoefer, D; Handel, M; Müller, K-M; Hammer, T R

    2016-11-01

    Neurophysiologic data on reactions of the human brain towards tactile stimuli evoked by fabrics moved on the skin are scarce. Furthermore, evaluation of fabrics' pleasantness using questionnaires suffers subjective biases. That is why we used a 64-channel electroencephalography (EEG) to objectively evaluate real-time brain reactions to fabric-skin interactions. Tactile stimuli were triggered by selected fabrics of different qualities, i.e. modal/polyamide single jersey, cotton double rib and a jute fabric, applied hidden to either the palm or forearm of 24 subjects via a custom-made fabric-to-skin applicator called SOFIA. One-way anova analysis was carried out to verify the EEG data. The modal/polyamide fabric applied to the forearm and palm led to slightly stronger emotional valence scores in the brain than the conventional or baseline fabric. Furthermore, the single jersey elicits significant higher event-related potential (ERP) signals in all subjects when applied to the forearm, suggesting less distraction and better cognitive resources during the fabric/skin interaction. The brain thus reacts with instantaneous ERP to tactile stimulation of fabrics and is able to discriminate different qualities via implicit preferences. The test procedure described here may be a tool to evaluate the fabric feel with the exclusion of subjective biases. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. A Osteogenesis Distraction Device Enabling Control of Vertical Direction for Syndromic Craniosynostosis

    PubMed Central

    Fukawa, Toshihiko; Hirakawa, Takashi; Maegawa, Jiro

    2014-01-01

    Background: We have developed a hybrid facial osteogenesis distraction system that combines the advantages of external and internal distraction devices to enable control of both the distraction distance and vector. However, when the advanced maxilla has excessive clockwise rotation and shifts more downward vertically than planned, it might be impossible to pull it up to correct it. We invented devices attached to external distraction systems that can control the vertical vector of distraction to resolve this problem. The purpose of this article is to describe the result of utilizing the distraction system for syndromic craniosynostosis. Methods: In addition to a previously reported hybrid facial distraction system, the devices for controlling the vertical direction of the advanced maxilla were attached to the external distraction device. The vertical direction of the advanced maxilla can be controlled by adjustment of the spindle units. This system was used for 2 patients with Crouzon and Apert syndrome. Results: The system enabled control of the vertical distance, with no complications during the procedures. As a result, the maxilla could be advanced into the planned position including overcorrection without excessive clockwise rotation of distraction. Conclusion: Our system can alter the cases and bring them into the planned position, by controlling the vertical vector of distraction. We believe that this system might be effective in infants with syndromic craniosynostosis as it involves 2 osteotomies and horizontal and vertical direction of elongation can be controlled. PMID:25289307

  6. Site-specific differences in the association between plantar tactile perception and mobility function in older adults

    PubMed Central

    Cruz-Almeida, Yenisel; Black, Mieniecia L.; Christou, Evangelos A.; Clark, David J.

    2014-01-01

    Introduction: Impaired somatosensation is common in older adults and contributes to age-related loss of mobility function. However, little is known about whether somatosensation at different sites on the plantar surface of the foot are differentially related to mobility function. Such a finding may have important implications for clinical care of older adults and other at-risk populations, such as for optimizing interventions (e.g., footwear for augmenting somatosensory feedback) and for improving the efficiency of clinical assessment. Materials and Methods: Tactile perception was evaluated with a 10 g monofilament at four sites on the plantar surface of each foot: great toe (GT), first metatarsal head (MT1), heel (H) and fifth metatarsal head (MT5). Mobility function was assessed with the Berg Balance Scale and walking speed. Results: Sixty-one older adults participated. Tactile perception was significantly positively associated with Berg Balance Score (adjusted r = 0.30 − 0.75; p = 0.03 − < 0.001), with the strongest association found at the site of the MT1. Only at this site was tactile perception found to be significantly associated with usual walking speed (adjusted r = 0.51; p < 0.001) and maximal walking speed (adjusted r = 0.38, p = 0.004). Clinically mild somatosensory impairment at MT1, but not at other sites, was found to yield substantial deficits in both Berg Balance Score and walking speed. Discussion: The present findings indicate that tactile perception at MT1 is more closely linked to mobility function than is tactile perception at GT, MT5 or H. These findings warrant further research to examine whether interventions (e.g., textured insoles) and assessments that preferentially or exclusively focus on the site of MT1 may be more effective for optimizing clinical care. PMID:24782765

  7. Tactile Sensitivity in Asperger Syndrome

    ERIC Educational Resources Information Center

    Blakemore, Sarah-Jayne; Tavassoli, Teresa; Calo, Susana; Thomas, Richard M.; Catmur, Caroline; Frith, Uta; Haggard, Patrick

    2006-01-01

    People with autism and Asperger syndrome are anecdotally said to be hypersensitive to touch. In two experiments, we measured tactile thresholds and suprathreshold tactile sensitivity in a group of adults with Asperger syndrome. In the first experiment, tactile perceptual thresholds were measured. Two frequencies of vibrotactile stimulation were…

  8. Dissociated active and passive tactile shape recognition: a case study of pure tactile apraxia.

    PubMed

    Valenza, N; Ptak, R; Zimine, I; Badan, M; Lazeyras, F; Schnider, A

    2001-11-01

    Disorders of tactile object recognition (TOR) may result from primary motor or sensory deficits or higher cognitive impairment of tactile shape representations or semantic memory. Studies with healthy participants suggest the existence of exploratory motor procedures directly linked to the extraction of specific properties of objects. A pure deficit of these procedures without concomitant gnostic disorders has never been described in a brain-damaged patient. Here, we present a patient with a right hemispheric infarction who, in spite of intact sensorimotor functions, had impaired TOR with the left hand. Recognition of 2D shapes and objects was severely deficient under the condition of spontaneous exploration. Tactile exploration of shapes was disorganized and exploratory procedures, such as the contour-following strategy, which is necessary to identify the precise shape of an object, were severely disturbed. However, recognition of 2D shapes under manually or verbally guided exploration and the recognition of shapes traced on the skin were intact, indicating a dissociation in shape recognition between active and passive touch. Functional MRI during sensory stimulation of the left hand showed preserved activation of the spared primary sensory cortex in the right hemisphere. We interpret the deficit of our patient as a pure tactile apraxia without tactile agnosia, i.e. a specific inability to use tactile feedback to generate the exploratory procedures necessary for tactile shape recognition.

  9. Neural correlates of tactile perception during pre-, peri-, and post-movement.

    PubMed

    Juravle, Georgiana; Heed, Tobias; Spence, Charles; Röder, Brigitte

    2016-05-01

    Tactile information is differentially processed over the various phases of goal-directed movements. Here, event-related potentials (ERPs) were used to investigate the neural correlates of tactile and visual information processing during movement. Participants performed goal-directed reaches for an object placed centrally on the table in front of them. Tactile and visual stimulation (100 ms) was presented in separate trials during the different phases of the movement (i.e. preparation, execution, and post-movement). These stimuli were independently delivered to either the moving or resting hand. In a control condition, the participants only performed the movement, while omission (i.e. movement-only) ERPs were recorded. Participants were instructed to ignore the presence or absence of any sensory events and to concentrate solely on the execution of the movement. Enhanced ERPs were observed 80-200 ms after tactile stimulation, as well as 100-250 ms after visual stimulation: These modulations were greatest during the execution of the goal-directed movement, and they were effector based (i.e. significantly more negative for stimuli presented to the moving hand). Furthermore, ERPs revealed enhanced sensory processing during goal-directed movements for visual stimuli as well. Such enhanced processing of both tactile and visual information during the execution phase suggests that incoming sensory information is continuously monitored for a potential adjustment of the current motor plan. Furthermore, the results reported here also highlight a tight coupling between spatial attention and the execution of motor actions.

  10. Tactile functions after cerebral hemispherectomy.

    PubMed

    Backlund, H; Morin, C; Ptito, A; Bushnell, M C; Olausson, H

    2005-01-01

    Patients that were hemispherectomized due to brain lesions early in life sometimes have remarkably well-preserved tactile functions on their paretic body half. This has been attributed to developmental neuroplasticity. However, the tactile examinations generally have been fairly crude, and subtle deficits may not have been revealed. We investigated monofilament detection and three types of tactile directional sensibility in four hemispherectomized patients and six healthy controls. Patients were examined bilaterally on the face, forearm and lower leg. Normal subjects were examined unilaterally. Following each test of directional sensibility, subjects were asked to rate the intensity of the stimulation. On the nonparetic side, results were almost always in the normal range. On the paretic side, the patients' capacity for monofilament detection was less impaired than their directional sensibility. Despite the disturbed directional sensibility on their paretic side the patients rated tactile sensations evoked by the stimuli, on both their paretic and nonparetic body halves, as more intense than normals. Thus, mechanisms of plasticity seem adequate for tactile detection and intensity coding but not for more complex tactile functions such as directional sensibility. The reason for the high vulnerability of tactile directional sensibility may be that it depends on spatially and temporally precise afferent information processed in a distributed cortical network.

  11. Recent Progress in Technologies for Tactile Sensors

    PubMed Central

    Sun, Xuguang; Xue, Ning; Li, Tong; Liu, Chang

    2018-01-01

    Over the last two decades, considerable scientific and technological efforts have been devoted to developing tactile sensing based on a variety of transducing mechanisms, with prospective applications in many fields such as human–machine interaction, intelligent robot tactile control and feedback, and tactile sensorized minimally invasive surgery. This paper starts with an introduction of human tactile systems, followed by a presentation of the basic demands of tactile sensors. State-of-the-art tactile sensors are reviewed in terms of their diverse sensing mechanisms, design consideration, and material selection. Subsequently, typical performances of the sensors, along with their advantages and disadvantages, are compared and analyzed. Two major potential applications of tactile sensing systems are discussed in detail. Lastly, we propose prospective research directions and market trends of tactile sensing systems. PMID:29565835

  12. Recent Progress in Technologies for Tactile Sensors.

    PubMed

    Chi, Cheng; Sun, Xuguang; Xue, Ning; Li, Tong; Liu, Chang

    2018-03-22

    Over the last two decades, considerable scientific and technological efforts have been devoted to developing tactile sensing based on a variety of transducing mechanisms, with prospective applications in many fields such as human-machine interaction, intelligent robot tactile control and feedback, and tactile sensorized minimally invasive surgery. This paper starts with an introduction of human tactile systems, followed by a presentation of the basic demands of tactile sensors. State-of-the-art tactile sensors are reviewed in terms of their diverse sensing mechanisms, design consideration, and material selection. Subsequently, typical performances of the sensors, along with their advantages and disadvantages, are compared and analyzed. Two major potential applications of tactile sensing systems are discussed in detail. Lastly, we propose prospective research directions and market trends of tactile sensing systems.

  13. Tactile modulation of hippocampal place fields.

    PubMed

    Gener, Thomas; Perez-Mendez, Lorena; Sanchez-Vives, Maria V

    2013-12-01

    Neural correlates of spatial representation can be found in the activity of the hippocampal place cells. These neurons are characterized by firing whenever the animal is located in a particular area of the space, the place field. Place fields are modulated by sensory cues, such as visual, auditory, or olfactory cues, being the influence of visual inputs the most thoroughly studied. Tactile information gathered by the whiskers has a prominent representation in the rat cerebral cortex. However, the influence of whisker-detected tactile cues on place fields remains an open question. Here we studied place fields in an enriched tactile environment where the remaining sensory cues were occluded. First, place cells were recorded before and after blockade of tactile transmission by means of lidocaine applied on the whisker pad. Following tactile deprivation, the majority of place cells decreased their firing rate and their place fields expanded. We next rotated the tactile cues and 90% of place fields rotated with them. Our results demonstrate that tactile information is integrated into place cells at least in a tactile-enriched arena and when other sensory cues are not available. Copyright © 2013 Wiley Periodicals, Inc.

  14. Electronic gaming as pain distraction

    PubMed Central

    Jameson, Eleanor; Trevena, Judy; Swain, Nic

    2011-01-01

    The current study investigated whether active distraction reduces participants’ experience of pain more than passive distraction during a cold pressor task. In the first experiment, 60 participants were asked to submerge their hand in cold (2°C) water for as long as they could tolerate. They did this with no distraction, and then with active (electronic gaming system) and passive (television) distraction, in randomly assigned order. Tolerance time, pain intensity ratings and task absorption ratings were measured for each condition. A second experiment attempted to control for participants’ expectations about the effects of distraction on pain. Forty participants underwent the same experimental procedure, but were given verbal suggestions about the effects of distraction by the experimenter before each distraction condition. Participants in both experiments had a significantly higher pain tolerance and reported less pain with the active distraction compared with passive or no distraction. Participants reported being more absorbed, and were significantly more willing to do the task again when they had the active distraction compared with both passive distraction and no distraction. They also had more enjoyment, less anxiety and greater reduction in pain with active distraction than with passive distraction. There was no effect of suggestion. These experiments offer further support for the use of electronic games as a method of pain control. PMID:21369538

  15. Electronic gaming as pain distraction.

    PubMed

    Jameson, Eleanor; Trevena, Judy; Swain, Nic

    2011-01-01

    The current study investigated whether active distraction reduces participants' experience of pain more than passive distraction during a cold pressor task. In the first experiment, 60 participants were asked to submerge their hand in cold (2°C) water for as long as they could tolerate. They did this with no distraction, and then with active (electronic gaming system) and passive (television) distraction, in randomly assigned order. Tolerance time, pain intensity ratings and task absorption ratings were measured for each condition. A second experiment attempted to control for participants' expectations about the effects of distraction on pain. Forty participants underwent the same experimental procedure, but were given verbal suggestions about the effects of distraction by the experimenter before each distraction condition. Participants in both experiments had a significantly higher pain tolerance and reported less pain with the active distraction compared with passive or no distraction. Participants reported being more absorbed, and were significantly more willing to do the task again when they had the active distraction compared with both passive distraction and no distraction. They also had more enjoyment, less anxiety and greater reduction in pain with active distraction than with passive distraction. There was no effect of suggestion. These experiments offer further support for the use of electronic games as a method of pain control.

  16. Distraction rate and latency: factors in the outcome of paediatric maxillary distraction.

    PubMed

    Higuera, Stephen; Cole, Patrick; Stephenson, J B; Hollier, Larry

    2009-12-01

    Over 50 years ago, current tenets of distraction osteogenesis were developed through work on the lower extremity; however, the application of these tenets in the paediatric craniofacial skeleton remains questionable. Prompted by recent concern that traditional aspects of distraction may be either outdated or wholly inapplicable to the paediatric maxilla, we retrospectively evaluated maxillary distraction protocol using a 24-h latency period in conjunction with a distraction rate of 2mm/day. Following maxillary advancement via a distraction protocol consisting of a 24-h latency period and a distraction rate of 2mm/day, seven consecutive paediatric cases were evaluated. Standard profile photos and cephalometric films taken preoperatively, at device removal and at 1-year follow-up were compared. With the sella as the point of registration, pre- and post-distraction films were superimposed on the sella-nasion plane. Sella-nasion-subspinale, the angle of convexity, the distance from incisal edges to the y-axis, and angulation of the upper incisor to the sella-nasion plane were analysed to evaluate hard-tissue changes. Patient age ranged from 3 to 14 years (mean=7.43 years). Maxillary distraction length averaged 11 mm (range=10-12 mm). Interval from device application to removal averaged 98 days (range=75-180 days). The interval of the active distraction ranged from 11 to 65 days (mean=24 days). From distraction completion to device removal averaged 85 days (range=60-150). Follow-up intervals ranged from 52 to 24 months (mean=34 months). All patients demonstrated substantial clinical advancement of the maxilla with correction of midfacial deficiencies. A single patient developed mild cellulitis at one skin-device interface; no other complications were noted. Cephalometric and clinical evaluations at 1 year post-distraction demonstrated stable results, and parental satisfaction was qualitatively high. The surgical dogma of lower-extremity distraction osteogenesis is not

  17. Distracted by Your Mind? Individual Differences in Distractibility Predict Mind Wandering

    ERIC Educational Resources Information Center

    Forster, Sophie; Lavie, Nilli

    2014-01-01

    Attention may be distracted from its intended focus both by stimuli in the external environment and by internally generated task-unrelated thoughts during mind wandering. However, previous attention research has focused almost exclusively on distraction by external stimuli, and the extent to which mind wandering relates to external distraction is…

  18. Optical-to-Tactile Translator

    NASA Technical Reports Server (NTRS)

    Langevin, Maurice L. (Inventor); Moynihan, Philip I. (Inventor)

    2000-01-01

    An optical-to-tactile translator provides an aid for the visually impaired by translating a near-field scene to a tactile signal corresponding to said near-field scene. An optical sensor using a plurality of active pixel sensors (APS) converts the optical image within the near-field scene to a digital signal. The digital signal is then processed by a microprocessor and a simple shape signal is generated based on the digital signal. The shape signal is then communicated to a tactile transmitter where the shape signal is converted into a tactile signal using a series of contacts. The shape signal may be an outline of the significant shapes determined in the near-field scene, or the shape signal may comprise a simple symbolic representation of common items encountered repeatedly. The user is thus made aware of the unseen near-field scene, including potential obstacles and dangers, through a series of tactile contacts. In a preferred embodiment, a range determining device such as those commonly found on auto-focusing cameras is included to limit the distance that the optical sensor interprets the near-field scene.

  19. Tactile-Sensing Based on Flexible PVDF Nanofibers via Electrospinning: A Review

    PubMed Central

    Wang, Xiaomei; Sun, Fazhe; Yin, Guangchao; Wang, Yuting; Liu, Bo

    2018-01-01

    The flexible tactile sensor has attracted widespread attention because of its great flexibility, high sensitivity, and large workable range. It can be integrated into clothing, electronic skin, or mounted on to human skin. Various nanostructured materials and nanocomposites with high flexibility and electrical performance have been widely utilized as functional materials in flexible tactile sensors. Polymer nanomaterials, representing the most promising materials, especially polyvinylidene fluoride (PVDF), PVDF co-polymer and their nanocomposites with ultra-sensitivity, high deformability, outstanding chemical resistance, high thermal stability and low permittivity, can meet the flexibility requirements for dynamic tactile sensing in wearable electronics. Electrospinning has been recognized as an excellent straightforward and versatile technique for preparing nanofiber materials. This review will present a brief overview of the recent advances in PVDF nanofibers by electrospinning for flexible tactile sensor applications. PVDF, PVDF co-polymers and their nanocomposites have been successfully formed as ultrafine nanofibers, even as randomly oriented PVDF nanofibers by electrospinning. These nanofibers used as the functional layers in flexible tactile sensors have been reviewed briefly in this paper. The β-phase content, which is the strongest polar moment contributing to piezoelectric properties among all the crystalline phases of PVDF, can be improved by adjusting the technical parameters in electrospun PVDF process. The piezoelectric properties and the sensibility for the pressure sensor are improved greatly when the PVDF fibers become more oriented. The tactile performance of PVDF composite nanofibers can be further promoted by doping with nanofillers and nanoclay. Electrospun P(VDF-TrFE) nanofiber mats used for the 3D pressure sensor achieved excellent sensitivity, even at 0.1 Pa. The most significant enhancement is that the aligned electrospun core-shell P

  20. Blind Braille readers mislocate tactile stimuli.

    PubMed

    Sterr, Annette; Green, Lisa; Elbert, Thomas

    2003-05-01

    In a previous experiment, we observed that blind Braille readers produce errors when asked to identify on which finger of one hand a light tactile stimulus had occurred. With the present study, we aimed to specify the characteristics of this perceptual error in blind and sighted participants. The experiment confirmed that blind Braille readers mislocalised tactile stimuli more often than sighted controls, and that the localisation errors occurred significantly more often at the right reading hand than at the non-reading hand. Most importantly, we discovered that the reading fingers showed the smallest error frequency, but the highest rate of stimulus attribution. The dissociation of perceiving and locating tactile stimuli in the blind suggests altered tactile information processing. Neuroplasticity, changes in tactile attention mechanisms as well as the idea that blind persons may employ different strategies for tactile exploration and object localisation are discussed as possible explanations for the results obtained.

  1. [Callus distraction].

    PubMed

    Giebel, G

    1995-09-01

    Fibroblast networks that form collagen and connect the two ends of bone develop in the haematoma after corticotomy. This regenerative tissue is vascularized and distracted. Even during the lengthening, mineralization starts. This starts at the ends created by the osteotomy, in the form of conical bony columns 200 microns thick, which grows towards each other in a manner reminiscent of stalagmites and stalactites, until the central, fibrous inner zone (growth zone) formed during distraction is completely mineralized. Connective tissue and bony bars are arranged lengthwise. As a rule, intramembranous callus formation takes place during distraction osteogenesis with no intermediate cartilaginous step.

  2. Driven to Distraction.

    PubMed

    Strayer, David L; Cooper, Joel M

    2015-12-01

    We address several themes that emerged in the commentaries related to our target article. First, we consider the relationship between cognitive distraction and crash risk. Second, we discuss the development of our cognitive distraction scale. Third, we weigh issues of self-regulation, appropriate baselines, and satisficing. Finally, we identify several areas where additional research is needed to refine our understanding of driver distraction and crash risk. © 2015, Human Factors and Ergonomics Society.

  3. Maxillary distraction in patients with cleft deformity using a rigid external distraction device: a pilot study on the distraction ratio of the maxilla to the device.

    PubMed

    Harada, Kiyoshi; Sato, Masaru; Omura, Ken

    2004-01-01

    We examined the ratio between actual maxillary distraction and the distraction of the rigid external distraction device (Rigid external distraction (RED) system) used for maxillary distraction in patients with a cleft deformity. Twelve patients were examined. The amount of maxillary advancement was measured on lateral cephalograms and divided by the activation amount on the RED system. The value obtained was represented as the distraction ratio of the maxilla to the system. The mean ratio in 10 patients with complete cleft lip, palate, and alveolus (complete cleft) was 0.24. However, the ratios in two patients with cleft lip and alveolus or soft cleft palate (incomplete cleft) were considerably higher than the mean ratios in patients with complete cleft. When the maxilla is distracted in patients with complete cleft using the RED system, the amount of activation on the system needs to be about four times the amount of planned maxillary distraction. However, the distraction ratio may be affected by the type of cleft.

  4. Measurement of torque during mandibular distraction.

    PubMed

    Burstein, Fernando D; Lukas, Saylan; Forsthoffer, Dina

    2008-05-01

    In a prospective study, 26 patients aged 9 days to 12 years old underwent mandibular distraction. There were 18 bilateral and 8 unilateral distractions performed. Five patients had previous distraction. Torque measurements were performed during the distraction process. A modest linear increase in torque was noted during the distraction process. Older patients required more torque to achieve the same distraction length as younger patients. The results of this study suggest that distraction forces are relatively modest, which may allow for greater freedom of distractor design.

  5. Visual attention in violent offenders: Susceptibility to distraction.

    PubMed

    Slotboom, Jantine; Hoppenbrouwers, Sylco S; Bouman, Yvonne H A; In 't Hout, Willem; Sergiou, Carmen; van der Stigchel, Stefan; Theeuwes, Jan

    2017-05-01

    Impairments in executive functioning give rise to reduced control of behavior and impulses, and are therefore a risk factor for violence and criminal behavior. However, the contribution of specific underlying processes remains unclear. A crucial element of executive functioning, and essential for cognitive control and goal-directed behavior, is visual attention. To further elucidate the importance of attentional functioning in the general offender population, we employed an attentional capture task to measure visual attention. We expected offenders to have impaired visual attention, as revealed by increased attentional capture, compared to healthy controls. When comparing the performance of 62 offenders to 69 healthy community controls, we found our hypothesis to be partly confirmed. Offenders were more accurate overall, more accurate in the absence of distracting information, suggesting superior attention. In the presence of distracting information offenders were significantly less accurate compared to when no distracting information was present. Together, these findings indicate that violent offenders may have superior attention, yet worse control over attention. As such, violent offenders may have trouble adjusting to unexpected, irrelevant stimuli, which may relate to failures in self-regulation and inhibitory control. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  6. The early psychological adjustment of cleft patients after maxillary distraction osteogenesis and conventional orthognathic surgery: a preliminary study.

    PubMed

    Cheung, Lim Kwong; Loh, John Ser Pheng; Ho, Samuel M Y

    2006-12-01

    To compare the early psychological changes of cleft lip and palate (CLP) and noncleft patients after maxillofacial corrective surgery, including maxillary distraction osteogenesis and conventional orthognathic surgery. Nine CLP patients were compared with a group of 9 non-CLP patients having similar dentofacial deformities in a prospective longitudinal cohort study. Five of the CLP patients underwent maxillary distraction osteogenesis and 4 underwent conventional orthognathic surgery. A control group of 9 noncleft patients received conventional orthognathic surgery. All patients completed a set of questionnaires to enable their psychological profile to be assessed. The data were collected immediately before surgery (T1), and at 3 weeks (T2) and 12 weeks (T3) after surgery. The CLP patients treated with distraction osteogenesis were happier, but had a higher level of social anxiety and distress than the CLP patients receiving conventional orthognathic surgery. On the other hand, the CLP patients overall were happier, with lower social anxiety and distress, than the noncleft control group. The CLP patients showed a higher level of parental self-esteem than the noncleft patients. This preliminary study shows that CLP patients were generally happier, and had a higher level of parental support, than normal patients suffering from dentofacial deformities. Maxillary distraction osteogenesis seemed to induce a higher level of anxiety and distress in CLP patients than conventional orthognathic surgery in both cleft and noncleft patients.

  7. Reflections of Distraction in Memory: Transfer of Previous Distraction Improves Recall in Younger and Older Adults

    PubMed Central

    Thomas, Ruthann C.; Hasher, Lynn

    2012-01-01

    Three studies explored whether younger and older adults’ free recall performance can benefit from prior exposure to distraction that becomes relevant in a memory task. Participants initially read stories that included distracting text. Later, they studied a list of words for free recall, with half of the list consisting of previously distracting words. When the memory task was indirect in its use of distraction (Study 1), only older adults showed transfer, with better recall of previously distracting compared with new words, which increased their recall to match that of younger adults. However, younger adults showed transfer when cued about the relevance of previous distraction both before studying the words (Study 2) and before recalling the words (Study 3) in the memory test. Results suggest that both younger and older adults encode distraction, but younger adults require explicit cueing to use their knowledge of distraction. In contrast, older adults transfer knowledge of distraction in both explicitly cued and indirect memory tasks. Results are discussed in terms of age differences in inhibition and source-constrained retrieval. PMID:21843024

  8. Reflections of distraction in memory: transfer of previous distraction improves recall in younger and older adults.

    PubMed

    Thomas, Ruthann C; Hasher, Lynn

    2012-01-01

    Three studies explored whether younger and older adults' free recall performance can benefit from prior exposure to distraction that becomes relevant in a memory task. Participants initially read stories that included distracting text. Later, they studied a list of words for free recall, with half of the list consisting of previously distracting words. When the memory task was indirect in its use of distraction (Study 1), only older adults showed transfer, with better recall of previously distracting compared with new words, which increased their recall to match that of younger adults. However, younger adults showed transfer when cued about the relevance of previous distraction both before studying the words (Study 2) and before recalling the words (Study 3) in the memory test. Results suggest that both younger and older adults encode distraction, but younger adults require explicit cueing to use their knowledge of distraction. In contrast, older adults transfer knowledge of distraction in both explicitly cued and indirect memory tasks. Results are discussed in terms of age differences in inhibition and source-constrained retrieval.

  9. Auditory-tactile echo-reverberating stuttering speech corrector

    NASA Astrophysics Data System (ADS)

    Kuniszyk-Jozkowiak, Wieslawa; Adamczyk, Bogdan

    1997-02-01

    The work presents the construction of a device, which transforms speech sounds into acoustical and tactile signals of echo and reverberation. Research has been done on the influence of the echo and reverberation, which are transmitted as acoustic and tactile stimuli, on speech fluency. Introducing the echo or reverberation into the auditory feedback circuit results in a reduction of stuttering. A bit less, but still significant corrective effects are observed while using the tactile channel for transmitting the signals. The use of joined auditory and tactile channels increases the effects of their corrective influence on the stutterers' speech. The results of the experiment justify the use of the tactile channel in the stutterers' therapy.

  10. Breakage of internal maxillary distractor: considerable complication of maxillary distraction osteogenesis.

    PubMed

    Aikawa, Tomonao; Iida, Seiji; Isomura, Emiko T; Namikawa, Mari; Matsuoka, Yudai; Yamada, Chiaki; Yamamoto, Taku; Takigawa, Yoko

    2008-07-01

    Maxillary distraction osteogenesis using intraoral distractors is now one of the standard treatments of maxillary retrusion. This report shows 2 cases of breakage of this internal maxillary distractor in patients with cleft lip and palate; one was observed during the distraction period and the other was during the retention period. The first case required a rotational movement of the distraction segment, and this movement caused the laterally dislocation of the posterior part of the distractor, where the distractor suffered some mechanical forces by mouth opening. In the latter case, breakage of distractor was observed on the radiographs taken 3 months after distraction and this complication may have been caused by mechanical force by occlusion and mastication. Both breakages were found at the joint of the anchorage plate and the extension rod, which has some flexibility for adjusting the plate to the bone surface. Therefore, surgeons should pay special attention for this mechanical weak area in this distractor not only during the advancement period, but also during the retention period and should avoid unnecessary frequent bending for adopting the bone surface, which directly weakens the joint.

  11. Distraction systems for ankle arthroscopy.

    PubMed

    Palladino, S J

    1994-07-01

    It is clear that for most of the routine pathology addressed with ankle arthroscopy, including most talar dome transchondral fractures, manual distraction (or none at all) is all that is necessary to successfully complete the procedure. There is little need to add the expense and potential complications associated with some distraction systems. However, some cases involve pathology or surgical techniques that either would be better addressed with distraction or absolutely demand distraction. It is recommended that invasive ankle distraction be reserved for (1) cases in which noninvasive distraction has not yielded adequate field visualization or instrument maneuvering room, (2) cases of preoperatively documented pathology involving the posterior talar dome (including some medial talar dome fractures) or inferior tibial surface, or (3) arthroscopic ankle fusion. Consideration should be given to providing 6 to 12 weeks of protected function of the extremity to avoid delayed fracture presentation. In general, the invasive distraction system should be reserved for those cases that would not ordinarily be managed with aggressive rehabilitation and early return to activities. For those cases where the benefits of distraction are desired (some dome fractures, meniscoid lesions, gutter pathology, and adhesive capsulitis) and aggressive rehabilitation with early return to activities may be planned, noninvasive distraction systems are now available that offer a sustainable joint separation of good magnitude. With the growing availability and effectiveness of the commercial noninvasive ankle distractors, I do not disagree with Stone and Guhl98 when they advocate the use of noninvasive distraction for routine arthroscopic procedures, with conversion to invasive distraction should there be insufficient joint separation. In summary, providing optimal field visualization and maneuvering room for instrumentation is essential for the successful performance of arthroscopic ankle

  12. Distractibility in Attention/Deficit/ Hyperactivity Disorder (ADHD): the virtual reality classroom.

    PubMed

    Adams, Rebecca; Finn, Paul; Moes, Elisabeth; Flannery, Kathleen; Rizzo, Albert Skip

    2009-03-01

    Nineteen boys aged 8 to 14 with a diagnosis of ADHD and 16 age-matched controls were compared in a virtual reality (VR) classroom version of a continuous performance task (CPT), with a second standard CPT presentation using the same projection display dome system. The Virtual Classroom included simulated "real-world" auditory and visual distracters. Parent ratings of attention, hyperactivity, internalizing problems, and adaptive skills on the Behavior Assessment System for Children (BASC) Monitor for ADHD confirmed that the ADHD children had more problems in these areas than controls. The difference between the ADHD group (who performed worse) and the control group approached significance (p = .05; adjusted p = .02) in the Virtual Classroom presentation, and the classification rate of the Virtual Classroom was better than when the standard CPT was used (87.5% versus 68.8%). Children with ADHD were more affected by distractions in the VR classroom than those without ADHD. Results are discussed in relation to distractibility in ADHD.

  13. Linkage between Free Exploratory Movements and Subjective Tactile Ratings.

    PubMed

    Yokosaka, Takumi; Kuroki, Scinob; Watanabe, Junji; Nishida, Shinya

    2017-01-01

    We actively move our hands and eyes when exploring the external world and gaining information about object's attributes. Previous studies showing that how we touch might be related to how we felt led us to consider whether we could decode observers' subjective tactile experiences only by analyzing their exploratory movements without explicitly asking how they perceived. However, in those studies, explicit judgment tasks were performed about specific tactile attributes that were prearranged by experimenters. Here, we systematically investigated whether exploratory movements can explain tactile ratings even when participants do not need to judge any tactile attributes. While measuring both hand and eye movements, we asked participants to touch materials freely without judging any specific tactile attributes (free-touch task) or to evaluate one of four tactile attributes (roughness, hardness, slipperiness, and temperature). We found that tactile ratings in the judgment tasks correlated with exploratory movements even in the free-touch task and that eye movements as well as hand movements correlated with tactile ratings. These results might open up the possibility of decoding tactile experiences by exploratory movements.

  14. Exploration of the Effectiveness of Tactile Methods

    ERIC Educational Resources Information Center

    Aldajani, Neda F.

    2016-01-01

    This paper introduces the tactile method and aims to explore the effectiveness of using tactile methods with students who are blind and visually impaired. Although there was limited research about using this strategy, all of the research agrees that using tactile is one of the best ways for students who are blind and visually impaired to be…

  15. Fingertip-shaped optical tactile sensor for robotic applications

    NASA Technical Reports Server (NTRS)

    Begej, Stefan

    1988-01-01

    Progress is described regarding the development of a high-density, fiber-optic, fingertip-shaped tactile sensor specifically designed for application to dexterous robotics. The sensor operates on optical principles involving the frustration of total internal reflection at a waveguide/elastomer interface and generates a grey-scale tactile image that represents the normal forces of contact. The sensor contains 256 taxels (sensing sites) distributed in a dual-density pattern that includes a tactile fovea near the tip which measures 13 mm x 13 mm and contains 169 taxels. The details regarding the design and construction of this tactile sensor are presented, in addition to photographs of tactile imprints.

  16. Summary of Tactile User Interfaces Techniques and Systems

    NASA Technical Reports Server (NTRS)

    Spirkovska, Lilly

    2005-01-01

    Mental workload can be de.ned as the ratio of demand to allocated resources. Multiple-resource theory stresses the importance of distribution of tasks and information across various human sensory channels to reduce mental workload. One sensory channel that has been of interest since the late 1800s is touch. Unlike the more typical displays that target vision or hearing, tactile displays present information to the user s sense of touch. We present a summary of different methods for tactile display, historic and more recent systems that incorporate tactile display for information presentation, advantages and disadvantages of targeting the tactile channel, and future directions in tactile display research.

  17. Summary of Tactile User Interfaces Techniques and Systems

    NASA Technical Reports Server (NTRS)

    Spirkovska, Lilly

    2004-01-01

    Mental workload can be defined as the ratio of demand to allocated resources. Multiple- resource theory stresses the importance of distribution of tasks and information across various sensory channels of the human to reduce mental workload. One sensory channel that has been of interest since the late 1800s is touch. Unlike the more typical displays that target vision or hearing, tactile displays present information to the user s sense of touch. We present a summary of different methods for tactile display; historic and more recent systems that incorporate tactile display for information presentation; advantages and disadvantages of targeting the tactile channel; and future directions in tactile display research.

  18. A Tactile Carina Nebula

    NASA Astrophysics Data System (ADS)

    Grice, Noreen A.; Mutchler, M.

    2010-01-01

    Astronomy was once considered a science restricted to fully sighted participants. But in the past two decades, accessible books with large print/Braille and touchable pictures have brought astronomy and space science to the hands and mind's eye of students, regardless of their visual ability. A new universally-designed tactile image featuring the Hubble mosaic of the Carina Nebula is being presented at this conference. The original dataset was obtained with Hubble's Advanced Camera for Surveys (ACS) hydrogen-alpha filter in 2005. It became an instant icon after being infused with additional color information from ground-based CTIO data, and released as Hubble's 17th anniversary image. Our tactile Carina Nebula promotes multi-mode learning about the entire life-cycle of stars, which is dramatically illustrated in this Hubble mosaic. When combined with descriptive text in print and Braille, the visual and tactile components seamlessly reach both sighted and blind populations. Specific touchable features of the tactile image identify the shapes and orientations of objects in the Carina Nebula that include star-forming regions, jets, pillars, dark and light globules, star clusters, shocks/bubbles, the Keyhole Nebula, and stellar death (Eta Carinae). Visit our poster paper to touch the Carina Nebula!

  19. Articulated distraction.

    PubMed

    Hosny, Gamal Ahmed

    2011-07-01

    Articular hip distraction can be applied either by using a monolateral articulated distractor or a circular fixator. The fixator should be aligned such that its axis is aligned with the transverse axis of the hip joint. Following distraction, the range of motion is maintained with regular physiotherapy. It is a useful salvage procedure in older children with hip stiffness, when other methods of containment are not applicable. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Tactile communication.

    DOT National Transportation Integrated Search

    1962-05-01

    Tactile communication presents a relatively unexploited channel of information transmission in the field of aviation. Visual and auditory input channels frequently reach an information saturation point during various flight operations. A cutaneous co...

  1. Viewing the body modulates tactile receptive fields.

    PubMed

    Haggard, Patrick; Christakou, Anastasia; Serino, Andrea

    2007-06-01

    Tactile discrimination performance depends on the receptive field (RF) size of somatosensory cortical (SI) neurons. Psychophysical masking effects can reveal the RF of an idealized "virtual" somatosensory neuron. Previous studies show that top-down factors strongly affect tactile discrimination performance. Here, we show that non-informative vision of the touched body part influences tactile discrimination by modulating tactile RFs. Ten subjects performed spatial discrimination between touch locations on the forearm. Performance was improved when subjects saw their forearm compared to viewing a neutral object in the same location. The extent of visual information was relevant, since restricted view of the forearm did not have this enhancing effect. Vibrotactile maskers were placed symmetrically on either side of the tactile target locations, at two different distances. Overall, masking significantly impaired discrimination performance, but the spatial gradient of masking depended on what subjects viewed. Viewing the body reduced the effect of distant maskers, but enhanced the effect of close maskers, as compared to viewing a neutral object. We propose that viewing the body improves functional touch by sharpening tactile RFs in an early somatosensory map. Top-down modulation of lateral inhibition could underlie these effects.

  2. Thinking about touch facilitates tactile but not auditory processing.

    PubMed

    Anema, Helen A; de Haan, Alyanne M; Gebuis, Titia; Dijkerman, H Chris

    2012-05-01

    Mental imagery is considered to be important for normal conscious experience. It is most frequently investigated in the visual, auditory and motor domain (imagination of movement), while the studies on tactile imagery (imagination of touch) are scarce. The current study investigated the effect of tactile and auditory imagery on the left/right discriminations of tactile and auditory stimuli. In line with our hypothesis, we observed that after tactile imagery, tactile stimuli were responded to faster as compared to auditory stimuli and vice versa. On average, tactile stimuli were responded to faster as compared to auditory stimuli, and stimuli in the imagery condition were on average responded to slower as compared to baseline performance (left/right discrimination without imagery assignment). The former is probably due to the spatial and somatotopic proximity of the fingers receiving the taps and the thumbs performing the response (button press), the latter to a dual task cost. Together, these results provide the first evidence of a behavioural effect of a tactile imagery assignment on the perception of real tactile stimuli.

  3. Tactility and the body in early Chinese medicine.

    PubMed

    Hsu, Elisabeth

    2005-03-01

    If visual inspection of corpses was central to the development of anatomy in modern Europe, one may ask which of the senses was important for the emergence of the predominant currents of scholarly medical knowledge and practice in third- and second-century B.C.E. China? This article argues that it was tactile perception prompted by a tactile exploration of living bodies. The evidence, derived from a close reading of the Mawangdui medical manuscripts, the 105th chapter of the Records of the Historian, and selected passages from the Huang Di's Inner Canon, points to three important trends: first, the tactile exploration of the extremities led to a rich vocabulary of compound words for pain as localized in specific body parts; second, the tactile exploration of the mai gave rise to an even richer vocabulary on qualities of touch in pulse diagnostics; and third, the tactile exploration of the abdomen led to the assessment of the quality of the internal viscera with words that generally were used for describing the tactile quality of skin and flesh. This finding may appear surprising in the light of later developments during the dynastic history of Chinese medicine where tactile exploration of abdomen and extremities would appear unseemly. The author suggests that extensive tactile explorations of the body were possible before Confucius' teachings became a predominant aspect of state ideology.

  4. Learning tactile skills through curious exploration

    PubMed Central

    Pape, Leo; Oddo, Calogero M.; Controzzi, Marco; Cipriani, Christian; Förster, Alexander; Carrozza, Maria C.; Schmidhuber, Jürgen

    2012-01-01

    We present curiosity-driven, autonomous acquisition of tactile exploratory skills on a biomimetic robot finger equipped with an array of microelectromechanical touch sensors. Instead of building tailored algorithms for solving a specific tactile task, we employ a more general curiosity-driven reinforcement learning approach that autonomously learns a set of motor skills in absence of an explicit teacher signal. In this approach, the acquisition of skills is driven by the information content of the sensory input signals relative to a learner that aims at representing sensory inputs using fewer and fewer computational resources. We show that, from initially random exploration of its environment, the robotic system autonomously develops a small set of basic motor skills that lead to different kinds of tactile input. Next, the system learns how to exploit the learned motor skills to solve supervised texture classification tasks. Our approach demonstrates the feasibility of autonomous acquisition of tactile skills on physical robotic platforms through curiosity-driven reinforcement learning, overcomes typical difficulties of engineered solutions for active tactile exploration and underactuated control, and provides a basis for studying developmental learning through intrinsic motivation in robots. PMID:22837748

  5. Tactility as a function of grasp force: Effects of glove, orientation, pressure, load, and handle

    NASA Technical Reports Server (NTRS)

    Bishu, Ram R.; Bronkema, Lisa A.; Garcia, Dishayne; Klute, Glenn; Rajulu, Sudhakar

    1994-01-01

    One of the reasons for reduction in performance when gloves are donned is the lack of tactile sensitivity. It was argued that grasping force for a weight to be grasped will be a function of the weight to be lifted and the hand conditions. It was further reasoned that the differences in grasping force for various hand conditions will be a correlate of the tactile sensitivity of the corresponding hand conditions. The objective of this experiment, therefore, was to determine the effects of glove type, pressure, and weight of load on the initial grasping force and stable grasping force. It was hypothesized that when a person grasps an object, he/she grasps very firmly initially and then releases the grasp slightly after realizing what force is needed to maintain a steady grasp. This would seem to be particularly true when a person is wearing a glove and has lost some tactile sensitivity and force feedback during the grasp. Therefore, the ratio of initial force and stable force and the stable force itself would represent the amount of tactile adjustment that is made when picking up an object, and this adjustment should vary with the use of gloves. A dynamometer was fabricated to measure the grasping force; the tests were performed inside a glove box. Four female and four male subjects participated in the study, which measured the effects of four variables: load effect, gender effect, glove type, and pressure variance. The only significant effects on the peak and stable force were caused by gender and the weight of the load lifted. Neither gloves nor pressure altered these forces when compared to a bare-handed condition, as was suspected before the test. It is possible that gloves facilitate in holding due to coefficient of friction while they deter in peak grasp strength.

  6. Mechanisms behind distracted driving behavior: The role of age and executive function in the engagement of distracted driving

    PubMed Central

    Pope, Caitlin Northcutt; Bell, Tyler Reed; Stavrinos, Despina

    2016-01-01

    Performing secondary tasks, such as texting while driving, is associated with an increased risk of motor vehicle collisions (MVCs). While cognitive processes, such as executive function, are involved in driving, little is known about the relationship between executive control and willingness to engage in distracted driving. This study investigated the relationship between age, behavioral manifestations of executive function, and self-reported distracted driving behaviors. Executive difficulty (assessed with the BRIEF-A) as well as demographics (age and gender) was considered as possible predictors of engagement in distracted driving behaviors. Fifty-nine young, middle, and older adults self-reported executive difficulty and weekly engagement in distracted driving behaviors. Results revealed that while partially accounted for by age, global executive difficulty was uniquely related to engagement in distracted driving behaviors. Older age was associated with fewer weekly self-reported distracted driving behaviors while higher self-reported executive difficulty was associated with more frequent weekly engagement in distracted behavior. No significant differences were found between young and middle-aged adults on distracted driving behaviors. Findings conclude that distracted driving is a ubiquitous phenomenon evident in drivers of all ages. Possible mechanisms underlying distracted driving behavior could potentially be related to deficits in executive function. PMID:27716494

  7. Mechanisms behind distracted driving behavior: The role of age and executive function in the engagement of distracted driving.

    PubMed

    Pope, Caitlin Northcutt; Bell, Tyler Reed; Stavrinos, Despina

    2017-01-01

    Performing secondary tasks, such as texting while driving, is associated with an increased risk of motor vehicle collisions (MVCs). While cognitive processes, such as executive function, are involved in driving, little is known about the relationship between executive control and willingness to engage in distracted driving. This study investigated the relationship between age, behavioral manifestations of executive function, and self-reported distracted driving behaviors. Executive difficulty (assessed with the BRIEF-A) as well as demographics (age and gender) was considered as possible predictors of engagement in distracted driving behaviors. Fifty-nine young, middle, and older adults self-reported executive difficulty and weekly engagement in distracted driving behaviors. Results revealed that while partially accounted for by age, global executive difficulty was uniquely related to engagement in distracted driving behaviors. Older age was associated with fewer weekly self-reported distracted driving behaviors while higher self-reported executive difficulty was associated with more frequent weekly engagement in distracted behavior. No significant differences were found between young and middle-aged adults on distracted driving behaviors. Findings conclude that distracted driving is a ubiquitous phenomenon evident in drivers of all ages. Possible mechanisms underlying distracted driving behavior could potentially be related to deficits in executive function. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. The Cognitive and Neural Correlates of Tactile Memory

    ERIC Educational Resources Information Center

    Gallace, Alberto; Spence, Charles

    2009-01-01

    Tactile memory systems are involved in the storage and retrieval of information about stimuli that impinge on the body surface and objects that people explore haptically. Here, the authors review the behavioral, neuropsychological, neurophysiological, and neuroimaging research on tactile memory. This body of research reveals that tactile memory…

  9. Audio-Visual, Visuo-Tactile and Audio-Tactile Correspondences in Preschoolers.

    PubMed

    Nava, Elena; Grassi, Massimo; Turati, Chiara

    2016-01-01

    Interest in crossmodal correspondences has recently seen a renaissance thanks to numerous studies in human adults. Yet, still very little is known about crossmodal correspondences in children, particularly in sensory pairings other than audition and vision. In the current study, we investigated whether 4-5-year-old children match auditory pitch to the spatial motion of visual objects (audio-visual condition). In addition, we investigated whether this correspondence extends to touch, i.e., whether children also match auditory pitch to the spatial motion of touch (audio-tactile condition) and the spatial motion of visual objects to touch (visuo-tactile condition). In two experiments, two different groups of children were asked to indicate which of two stimuli fitted best with a centrally located third stimulus (Experiment 1), or to report whether two presented stimuli fitted together well (Experiment 2). We found sensitivity to the congruency of all of the sensory pairings only in Experiment 2, suggesting that only under specific circumstances can these correspondences be observed. Our results suggest that pitch-height correspondences for audio-visual and audio-tactile combinations may still be weak in preschool children, and speculate that this could be due to immature linguistic and auditory cues that are still developing at age five.

  10. Automated Continuous Distraction Osteogenesis May Allow Faster Distraction Rates: A Preliminary Study

    PubMed Central

    Peacock, Zachary S.; Tricomi, Brad; Murphy, Brian; Magill, John; Kaban, Leonard B.; Troulis, Maria

    2013-01-01

    Purpose To determine if automated continuous distraction osteogenesis at rates > 1mm/day would result in clinical and radiographic bone formation in a minipig model. Materials and Methods An automated, continuous, curvilinear distraction device was placed across a mandibular osteotomy in 10 minipigs. After 12 mm of distraction and 24 days fixation, animals were sacrificed and bone healing evaluated. The continuous distraction rates were 1.5 (n=5) and 3 mm/day (n=5). A semiquantitative scale was used to assess ex-vivo clinical appearance of the distraction gap (3= osteotomy not visible; 2= <50%; 1= >50%; 0= 100% visible); stability (3 = no mobility; 2 and 1 = mobility in 2 or 1 plane respectively; 0= mobility in 3 planes); radiographic density (4 = 100% gap opaque, 3= >75%, 2 = 50% – 75%, 1= <50%, or 0 = radiolucent). Groups of 4 minipigs distracted discontinuously at 1, 2, and 4 mm/day served as controls. Results The continuous DO 1.5 mm/day group had significantly higher scores for appearance and radiographic density compared to the discontinuous 4 mm/day group. The continuous DO 3mm/day group had significantly higher scores for appearance and radiographic density compared to the discontinuous 4 mm/day group, and higher stability compared to the discontinuous 2 and 4 mm/day groups. Conclusions Results of this preliminary study indicate that continuous DO at rates of 1.5 and 3.0 mm/day produces better bone formation when compared to discontinuous DO at rates faster than 1mm/day. PMID:23499159

  11. Disposed to distraction: Genetic variation in the cholinergic system influences distractibility but not time-on-task effects

    PubMed Central

    Berry, Anne S.; Demeter, Elise; Sabhapathy, Surya; English, Brett A.; Blakely, Randy D.; Sarter, Martin; Lustig, Cindy

    2015-01-01

    Both the passage of time and external distraction make it difficult to keep attention on the task at hand. We tested the hypothesis that time-on-task and external distraction pose independent challenges to attention, and that the brain’s cholinergic system selectively modulates our ability to resist distraction. Participants with a polymorphism limiting cholinergic capacity (Ile89Val variant (rs1013940) of the choline transporter gene SLC5A7) and matched controls completed self-report measures of attention and a laboratory task that measured decrements in sustained attention with and without distraction. We found evidence that distraction and time-on-task effects are independent and that the cholinergic system is strongly linked to greater vulnerability to distraction. Ile89Val participants reported more distraction during everyday life than controls, and their task performance was more severely impacted by the presence of an ecologically valid video distractor (similar to a television playing in the background). These results are the first to demonstrate a specific impairment in cognitive control associated with the Ile89Val polymorphism, and add to behavioral and cognitive neuroscience studies indicating the cholinergic system’s critical role in overcoming distraction. PMID:24666128

  12. Development and evolution of distraction devices: Use of indigenous appliances for Distraction Osteogenesis-An overview

    PubMed Central

    Andrade, Neelam; Gandhewar, Trupti; Kalra, Rinku

    2011-01-01

    An attempt has been made to review various devices as well as the outstanding studies done in the past for understanding the methodology of distraction for regeneration of bone. Lengthening of underdeveloped bones inclusive of the maxillofacial complex has been obtained by distraction osteogenesis by many authors. This could be achieved by the use of various extraoral or intraoral devices. Devices used for distraction osteogenesis must have a minimum of 2 important characteristics – they should be able to transfer distraction forces directly to the bone and secondly, should offer adequate rigidity for osseous consolidation to occur. With advanced technology and biomechanical engineering, preformed intraoral distraction devices are now available worldwide. The introduction of these intraoral bone-bourne devices have eliminated the need for bulky, cumbersome extraoral distraction devices which had problems such as external scars, pin tract infections, nerve or tooth bud injuries and poor patient compliance. The design of completely internalized custom made appliance has opened new vistas in the field of Oral and Maxillofacial Surgery. Indigenous internal devices are also economical and locally available. PMID:23482829

  13. Distraction manipulation reduction of an L5-S1 disk herniation.

    PubMed

    Cox, J M; Hazen, L J; Mungovan, M

    1993-06-01

    A computed tomography (CT)-confirmed L5-S1 disk protrusion is reported to be reduced following chiropractic adjustment, as seen on repeat CT scanning. Correlation of the CT reports with the patient's symptoms before and after manipulation is reported. A 38-yr-old female was treated for low back pain and right lower extremity first sacral dermatome sciatica. CT confirmed disk herniations at both the L4-L5 and L5-S1 levels were found. Motor weakness of the right gluteus maximus muscle was found and extremely tight hamstring muscles accompanying positive straight leg signs were elicited. A clinical and imaging diagnosis of an L5-S1 disk herniation was made. Distraction type chiropractic manipulation, electrical stimulation, exercises, nutrition advice and low back wellness class were administered with complete relief of sciatic pain and nearly complete relief of low back pain. Chiropractic distraction manipulation is an effective treatment of lumbar disk herniation, if the chiropractor is observant during its administration for patient tolerance to manipulation under distraction and any signs of neurological deficit demanding other types of care.

  14. Supraliminal but not subliminal distracters bias working memory recall.

    PubMed

    Wildegger, Theresa; Myers, Nicholas E; Humphreys, Glyn; Nobre, Anna C

    2015-06-01

    Information of which observers are not consciously aware can nevertheless influence perceptual processes. Whether subliminal information might exert an influence on working memory (WM) representations is less clear, and relatively few studies have examined the interactions between subliminal and supraliminal information in WM. We present 3 experiments examining this issue. Experiments 1a and b replicated the finding that orientation stimuli can influence behavior subliminally in a visuomotor priming task. Experiments 2 and 3 used the same orientation stimuli, but participants had to remember a target orientation and report it back by adjusting a probe orientation after a memory delay. Before or after presentation of the target orientation, a subliminal or supraliminal distracter orientation was presented that was either irrelevant for task completion and never had to be reported (Experiment 2), or was relevant for task completion because it had to be reported on some trials (Experiment 3). In both experiments, presentation of a supraliminal distracter influenced WM recall of the target orientation. When the distracter was presented subliminally, however, there was no bias in orientation recall. These results suggest that information stored in WM is protected from influences of subliminal stimuli, while online information processing is modulated by subliminal information. (c) 2015 APA, all rights reserved).

  15. Supraliminal But Not Subliminal Distracters Bias Working Memory Recall

    PubMed Central

    2015-01-01

    Information of which observers are not consciously aware can nevertheless influence perceptual processes. Whether subliminal information might exert an influence on working memory (WM) representations is less clear, and relatively few studies have examined the interactions between subliminal and supraliminal information in WM. We present 3 experiments examining this issue. Experiments 1a and b replicated the finding that orientation stimuli can influence behavior subliminally in a visuomotor priming task. Experiments 2 and 3 used the same orientation stimuli, but participants had to remember a target orientation and report it back by adjusting a probe orientation after a memory delay. Before or after presentation of the target orientation, a subliminal or supraliminal distracter orientation was presented that was either irrelevant for task completion and never had to be reported (Experiment 2), or was relevant for task completion because it had to be reported on some trials (Experiment 3). In both experiments, presentation of a supraliminal distracter influenced WM recall of the target orientation. When the distracter was presented subliminally, however, there was no bias in orientation recall. These results suggest that information stored in WM is protected from influences of subliminal stimuli, while online information processing is modulated by subliminal information. PMID:25867502

  16. Stress in Lumbar Intervertebral Discs during Distraction

    PubMed Central

    Gay, Ralph E.; Ilharreborde, Brice; Zhao, Kristin D.; Berglund, Lawrence J.; Bronfort, Gert; An, Kai-Nan

    2008-01-01

    BACKGROUND CONTEXT The intervertebral disc is a common source of low back pain. Prospective studies suggest that treatments that intermittently distract the disc might be beneficial for chronic low back pain. Although the potential exists for distraction therapies to affect the disc biomechanically their effect on intradiscal stress is debated. PURPOSE To determine if distraction alone, distraction combined with flexion or distraction combined with extension can reduce nucleus pulposus pressure and posterior anulus compressive stress in cadaveric lumbar discs compared to simulated standing or lying. STUDY DESIGN Laboratory study using single cadaveric motion segments. OUTCOME MEASURES Strain gauge measures of nucleus pulposus pressure and compressive stress in the anterior and posterior annulus fibrosus METHODS Intradiscal stress profilometry was performed on 15 motion segments during 5 simulated conditions: standing, lying, and 3 distracted conditions. Disc degeneration was graded by inspection from 1 (normal) to 4 (severe degeneration). RESULTS All distraction conditions markedly reduced nucleus pressure compared to either simulated standing or lying. There was no difference between distraction with flexion and distraction with extension in regard to posterior annulus compressive stress. Discs with little or no degeneration appeared to distributed compressive stress differently than those with moderate or severe degeneration. CONCLUSIONS Distraction appears to predictably reduce nucleus pulposus pressure. The effect of distraction therapy on the distribution of compressive stress may be dependent in part on the health of the disc. PMID:17981092

  17. Compliant Tactile Sensors

    NASA Technical Reports Server (NTRS)

    Torres-Jara, Eduardo R.

    2011-01-01

    Tactile sensors are currently being designed to sense interactions with human hands or pen-like interfaces. They are generally embedded in screens, keyboards, mousepads, and pushbuttons. However, they are not well fitted to sense interactions with all kinds of objects. A novel sensor was originally designed to investigate robotics manipulation where not only the contact with an object needs to be detected, but also where the object needs to be held and manipulated. This tactile sensor has been designed with features that allow it to sense a large variety of objects in human environments. The sensor is capable of detecting forces coming from any direction. As a result, this sensor delivers a force vector with three components. In contrast to most of the tactile sensors that are flat, this one sticks out from the surface so that it is likely to come in contact with objects. The sensor conforms to the object with which it interacts. This augments the contact's surface, consequently reducing the stress applied to the object. This feature makes the sensor ideal for grabbing objects and other applications that require compliance with objects. The operational range of the sensor allows it to operate well with objects found in peoples' daily life. The fabrication of this sensor is simple and inexpensive because of its compact mechanical configuration and reduced electronics. These features are convenient for mass production of individual sensors as well as dense arrays. The biologically inspired tactile sensor is sensitive to both normal and lateral forces, providing better feedback to the host robot about the object to be grabbed. It has a high sensitivity, enabling its use in manipulation fingers, which typically have low mechanical impedance in order to be very compliant. The construction of the sensor is simple, using inexpensive technologies like silicon rubber molding and standard stock electronics.

  18. Development of multichannel soft tactile sensors having fingerprint structure.

    PubMed

    Tsutsui, H; Murashima, Y; Honma, N; Kobayashi, K

    2014-01-01

    It is possible to accurately recognize the shape of an object or to grip it by setting soft tactile sensors on a robot's hands. We studied a multichannel soft tactile sensor as an artificial hand and evaluated the pressure's response performance from several directions and the slipping and sliding responses. The tactile sensor consisted of multiple pneumatic sensors and a soft cap with a fingerprint structure that was made of silicone gum and was separated from multiple spaces. Evaluation tests showed that the multiple soft tactile sensors estimate both an object's contact force and its contact location. Our tactile sensor also measured the object's roughness by the slide on surface texture.

  19. The Design of Tactile Thematic Symbols

    ERIC Educational Resources Information Center

    Lawrence, Megan M.; Lobben, Amy K.

    2011-01-01

    The study reported here investigated the design and legibility of tactile thematic maps, focusing on symbolization and the comprehension of spatial patterns on the maps. The results indicate that discriminable and effective tactile thematic maps can be produced using classed data with a microcapsule paper production method. The participants…

  20. Misunderstanding and Repair in Tactile Auslan

    ERIC Educational Resources Information Center

    Willoughby, Louisa; Manns, Howard; Iwasaki, Shimako; Bartlett, Meredith

    2014-01-01

    This article discusses ways in which misunderstandings arise in Tactile Australian Sign Language (Tactile Auslan) and how they are resolved. Of particular interest are the similarities to and differences from the same processes in visually signed and spoken conversation. This article draws on detailed conversation analysis (CA) and demonstrates…

  1. Assessment of distraction from erotic stimuli by nonerotic interference.

    PubMed

    Anderson, Alex B; Hamilton, Lisa Dawn

    2015-01-01

    Distraction from erotic cues during sexual encounters is a major contributor to sexual difficulties in men and women. Being able to assess distraction in studies of sexual arousal will help clarify underlying contributions to sexual problems. The current study aimed to identify the most accurate assessment of distraction from erotic cues in healthy men (n = 29) and women (n = 38). Participants were assigned to a no distraction, low distraction, or high distraction condition. Distraction was induced using an auditory distraction task presented during the viewing of an erotic video. Attention to erotic cues was assessed using three methods: a written quiz, a visual quiz, and a self-reported distraction measure. Genital and psychological sexual responses were also measured. Self-reported distraction and written quiz scores most accurately represented the level of distraction present, while self-reported distraction also corresponded with a decrease in genital arousal. Findings support the usefulness of self-report measures in conjunction with a brief quiz on the erotic material as the most accurate and sensitive ways to simply measure experimentally-induced distraction. Insight into distraction assessment techniques will enable evaluation of naturally occurring distraction in patients suffering from sexual problems.

  2. Crossmodal Congruency Benefits of Tactile and Visual Signalling

    DTIC Science & Technology

    2013-11-12

    modal information format seemed to produce faster and more accurate performance. The question of learning complex tactile communication signals...SECURITY CLASSIFICATION OF: We conducted an experiment in which tactile messages were created based on five common military arm and hand signals. We...compared response times and accuracy rates of novice individuals responding to visual and tactile representations of these messages, which were

  3. Young and Older Adults' Reading of Distracters

    ERIC Educational Resources Information Center

    Kemper, Susan; Mcdowd, Joan; Metcalf, Kim; Liu, Chiung-Ju

    2008-01-01

    Eye-tracking technology was employed to examine young and older adults' performance in the reading with distraction paradigm. Distracters of 1, 2, and 4 words that formed meaningful phrases were used. There were marked age differences in fixation patterns. Young adults' fixations to the distracters and targets increased with distracter length.…

  4. Observing the Use of Tactile Schedules

    ERIC Educational Resources Information Center

    Aasen, Gro; Naerland, Terje

    2014-01-01

    This article explores the use of tactile schedules in a heterogeneous sample of children with congenital blindness and varying degrees of additional disabilities. Basic conditions for the use of tactile schedules are proposed and discussed. Child behaviour indicative of some particular functions that can be attained with the use of tactile…

  5. Factors Affecting the Nonlinear Force Versus Distraction Height Curves in an In Vitro C5-C6 Anterior Cervical Distraction Model.

    PubMed

    Wen, Junxiang; Xu, Jianwei; Li, Lijun; Yang, Mingjie; Pan, Jie; Chen, Deyu; Jia, Lianshun; Tan, Jun

    2017-06-01

    In vitro biomechanical study of cervical intervertebral distraction. To investigate the forces required for distraction to different heights in an in vitro C5-C6 anterior cervical distraction model, focusing on the influence of the intervertebral disk, posterior longitudinal ligament (PLL), and ligamentum flavum (LF). No previous studies have reported on the forces required for distraction to various heights or the factors resisting distraction in anterior cervical discectomy and fusion. Anterior cervical distraction at C5-C6 was performed in 6 cadaveric specimens using a biomechanical testing machine, under 4 conditions: A, before disk removal; B, after disk removal; C, after disk and PLL removal; and D, after disk and PLL removal and cutting of the LF. Distraction was performed from 0 to 10 mm at a constant velocity (5 mm/min). Force and distraction height were recorded automatically. The force required increased with distraction height under all 4 conditions. There was a sudden increase in force required at 6-7 mm under conditions B and C, but not D. Under condition A, distraction to 5 mm required a force of 268.3±38.87 N. Under conditions B and C, distraction to 6 mm required <15 N, and further distraction required dramatically increased force, with distraction to 10 mm requiring 115.4±10.67 and 68.4±9.67 N, respectively. Under condition D, no marked increase in force was recorded. Distraction of the intervertebral space was much easier after disk removal. An intact LF caused a sudden marked increase in the force required for distraction, possibly indicating the point at which the LF was fully stretched. This increase in resistance may help to determine the optimal distraction height to avoid stress to the endplate spacer.

  6. Enhanced tactile encoding and memory recognition in congenital blindness.

    PubMed

    D'Angiulli, Amedeo; Waraich, Paul

    2002-06-01

    Several behavioural studies have shown that early-blind persons possess superior tactile skills. Since neurophysiological data show that early-blind persons recruit visual as well as somatosensory cortex to carry out tactile processing (cross-modal plasticity), blind persons' sharper tactile skills may be related to cortical re-organisation resulting from loss of vision early in their life. To examine the nature of blind individuals' tactile superiority and its implications for cross-modal plasticity, we compared the tactile performance of congenitally totally blind, low-vision and sighted children on raised-line picture identification test and re-test, assessing effects of task familiarity, exploratory strategy and memory recognition. What distinguished the blind from the other children was higher memory recognition and higher tactile encoding associated with efficient exploration. These results suggest that enhanced perceptual encoding and recognition memory may be two cognitive correlates of cross-modal plasticity in congenital blindness.

  7. Exploring Tactile Perceptual Dimensions Using Materials Associated with Sensory Vocabulary.

    PubMed

    Sakamoto, Maki; Watanabe, Junji

    2017-01-01

    Considering tactile sensation when designing products is important because the decision to purchase often depends on how products feel. Numerous psychophysical studies have attempted to identify important factors that describe tactile perceptions. However, the numbers and types of major tactile dimensions reported in previous studies have varied because of differences in materials used across experiments. To obtain a more complete picture of perceptual space with regard to touch, our study focuses on using vocabulary that expresses tactile sensations as a guiding principle for collecting material samples because these types of words are expected to cover all the basic categories within tactile perceptual space. We collected 120 materials based on a variety of Japanese sound-symbolic words for tactile sensations, and used the materials to examine tactile perceptual dimensions and their associations with affective evaluations. Analysis revealed six major dimensions: "Affective evaluation and Friction," "Compliance," "Surface," "Volume," "Temperature," and "Naturalness." These dimensions include four factors that previous studies have regarded as fundamental, as well as two new factors: "Volume" and "Naturalness." Additionally, we showed that "Affective evaluation" is more closely related to the "Friction" component (slipperiness and dryness) than to other tactile perceptual features. Our study demonstrates that using vocabulary could be an effective method for selecting material samples to explore tactile perceptual space.

  8. Tactile friction of topical formulations.

    PubMed

    Skedung, L; Buraczewska-Norin, I; Dawood, N; Rutland, M W; Ringstad, L

    2016-02-01

    The tactile perception is essential for all types of topical formulations (cosmetic, pharmaceutical, medical device) and the possibility to predict the sensorial response by using instrumental methods instead of sensory testing would save time and cost at an early stage product development. Here, we report on an instrumental evaluation method using tactile friction measurements to estimate perceptual attributes of topical formulations. Friction was measured between an index finger and an artificial skin substrate after application of formulations using a force sensor. Both model formulations of liquid crystalline phase structures with significantly different tactile properties, as well as commercial pharmaceutical moisturizing creams being more tactile-similar, were investigated. Friction coefficients were calculated as the ratio of the friction force to the applied load. The structures of the model formulations and phase transitions as a result of water evaporation were identified using optical microscopy. The friction device could distinguish friction coefficients between the phase structures, as well as the commercial creams after spreading and absorption into the substrate. In addition, phase transitions resulting in alterations in the feel of the formulations could be detected. A correlation was established between skin hydration and friction coefficient, where hydrated skin gave rise to higher friction. Also a link between skin smoothening and finger friction was established for the commercial moisturizing creams, although further investigations are needed to analyse this and correlations with other sensorial attributes in more detail. The present investigation shows that tactile friction measurements have potential as an alternative or complement in the evaluation of perception of topical formulations. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Effects of joint position on the distraction distance during grade III glenohumeral joint distraction in healthy individuals

    PubMed Central

    Park, Sam-Sik; Kim, Bo-Kyung; Moon, Ok-Kon; Choi, Wan-Suk

    2015-01-01

    [Purpose] The study investigated the effects of joint position on the distraction distance during Grade III glenohumeral joint distraction in healthy individuals. [Subjects and Methods] Twenty adults in their forties without shoulder disease were randomly divided into neutral position group (NPG; n = 7), resting position group (RPG; n = 7), and end range position group (ERPG; n = 6). After Kaltenborn Grade III distraction for 40s, the distance between glenoid fossa and humeral head was measured by ultrasound. [Results] The average distances between the humeral head and glenoid fossa before distraction were 2.86 ± 0.81, 3.21 ± 0.47, and 3.55 ± 0.59 mm for the NP, RP, and ERP groups. The distances after applying distraction were 3.12 ± 0.51, 3.86 ± 0.55, and 4.35 ± 0.32 mm. Between-group comparison after applying distraction revealed no significant differences between the NP and RP groups, while there was a statistically significant difference between the NP and RP groups, as well as between the NP and ERP groups. [Conclusion] Joint space was largest in ERP individuals when performing manual distraction. PMID:26644692

  10. Vector alignment in maxillary distraction osteogenesis.

    PubMed

    Uckan, Sina; Arman, Ayca; Bayram, Burak; Celik, Erkan

    2006-09-01

    Maxillary distraction osteogenesis is an alternative treatment of cleft patients with severe maxillary hypoplasia. The aim of this paper is to present the combined surgical/orthodontic treatment of a cleft lip and palate patient and to evaluate the maxillary distraction procedure and the distraction vector in high Le Fort I osteotomy.

  11. Path integration in tactile perception of shapes.

    PubMed

    Moscatelli, Alessandro; Naceri, Abdeldjallil; Ernst, Marc O

    2014-11-01

    Whenever we move the hand across a surface, tactile signals provide information about the relative velocity between the skin and the surface. If the system were able to integrate the tactile velocity information over time, cutaneous touch may provide an estimate of the relative displacement between the hand and the surface. Here, we asked whether humans are able to form a reliable representation of the motion path from tactile cues only, integrating motion information over time. In order to address this issue, we conducted three experiments using tactile motion and asked participants (1) to estimate the length of a simulated triangle, (2) to reproduce the shape of a simulated triangular path, and (3) to estimate the angle between two-line segments. Participants were able to accurately indicate the length of the path, whereas the perceived direction was affected by a direction bias (inward bias). The response pattern was thus qualitatively similar to the ones reported in classical path integration studies involving locomotion. However, we explain the directional biases as the result of a tactile motion aftereffect. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Virtual surface characteristics of a tactile display using magneto-rheological fluids.

    PubMed

    Lee, Chul-Hee; Jang, Min-Gyu

    2011-01-01

    Virtual surface characteristics of tactile displays are investigated to characterize the feeling of human touch for a haptic interface application. In order to represent the tactile feeling, a prototype tactile display incorporating Magneto-Rheological (MR) fluid has been developed. Tactile display devices simulate the finger's skin to feel the sensations of contact such as compliance, friction, and topography of the surface. Thus, the tactile display can provide information on the surface of an organic tissue to the surgeon in virtual reality. In order to investigate the compliance feeling of a human finger's touch, normal force responses of a tactile display under various magnetic fields have been assessed. Also, shearing friction force responses of the tactile display are investigated to simulate the action of finger dragging on the surface. Moreover, different matrix arrays of magnetic poles are applied to form the virtual surface topography. From the results, different tactile feelings are observed according to the applied magnetic field strength as well as the arrays of magnetic poles combinations. This research presents a smart tactile display technology for virtual surfaces.

  13. Planar and finger-shaped optical tactile sensors for robotic applications

    NASA Technical Reports Server (NTRS)

    Begej, Stefan

    1988-01-01

    Progress is described regarding the development of optical tactile sensors specifically designed for application to dexterous robotics. These sensors operate on optical principles involving the frustration of total internal reflection at a waveguide/elastomer interface and produce a grey-scale tactile image that represents the normal (vertical) forces of contact. The first tactile sensor discussed is a compact, 32 x 32 planar sensor array intended for mounting on a parallel-jaw gripper. Optical fibers were employed to convey the tactile image to a CCD camera and microprocessor-based image analysis system. The second sensor had the shape and size of a human fingertip and was designed for a dexterous robotic hand. It contained 256 sensing sites (taxels) distributed in a dual-density pattern that included a tactile fovea near the tip measuring 13 x 13 mm and containing 169 taxels. The design and construction details of these tactile sensors are presented, in addition to photographs of tactile imprints.

  14. Impact of social and technological distraction on pedestrian crossing behaviour: an observational study

    PubMed Central

    Thompson, Leah L; Rivara, Frederick P; Ayyagari, Rajiv C; Ebel, Beth E

    2013-01-01

    Objectives The objective of the present work was to study the impact of technological and social distraction on cautionary behaviours and crossing times in pedestrians. Methods Pedestrians were observed at 20 high-risk intersections during 1 of 3 randomly assigned time windows in 2012. Observers recorded demographic and behavioural information, including use of a mobile device (talking on the phone, text messaging, or listening to music). We examined the association between distraction and crossing behaviours, adjusting for age and gender. All multivariate analyses were conducted with random effect logistic regression (binary outcomes) and random effect linear regression (continuous outcomes), accounting for clustering by site. Results Observers recorded crossing behaviours for 1102 pedestrians. Nearly one-third (29.8%) of all pedestrians performed a distracting activity while crossing. Distractions included listening to music (11.2%), text messaging (7.3%) and using a handheld phone (6.2%). Text messaging, mobile phone use and talking with a companion increased crossing time. Texting pedestrians took 1.87 additional seconds (18.0%) to cross the average intersection (3.4 lanes), compared to undistracted pedestrians. Texting pedestrians were 3.9 times more likely than undistracted pedestrians to display at least 1 unsafe crossing behaviour (disobeying the lights, crossing mid-intersection, or failing to look both ways). Pedestrians listening to music walked more than half a second (0.54) faster across the average intersection than undistracted pedestrians. Conclusions Distracting activity is common among pedestrians, even while crossing intersections. Technological and social distractions increase crossing times, with text messaging associated with the highest risk. Our findings suggest the need for intervention studies to reduce risk of pedestrian injury. PMID:23243104

  15. Task demands affect spatial reference frame weighting during tactile localization in sighted and congenitally blind adults

    PubMed Central

    Schubert, Jonathan T. W.; Badde, Stephanie; Röder, Brigitte

    2017-01-01

    Task demands modulate tactile localization in sighted humans, presumably through weight adjustments in the spatial integration of anatomical, skin-based, and external, posture-based information. In contrast, previous studies have suggested that congenitally blind humans, by default, refrain from automatic spatial integration and localize touch using only skin-based information. Here, sighted and congenitally blind participants localized tactile targets on the palm or back of one hand, while ignoring simultaneous tactile distractors at congruent or incongruent locations on the other hand. We probed the interplay of anatomical and external location codes for spatial congruency effects by varying hand posture: the palms either both faced down, or one faced down and one up. In the latter posture, externally congruent target and distractor locations were anatomically incongruent and vice versa. Target locations had to be reported either anatomically (“palm” or “back” of the hand), or externally (“up” or “down” in space). Under anatomical instructions, performance was more accurate for anatomically congruent than incongruent target-distractor pairs. In contrast, under external instructions, performance was more accurate for externally congruent than incongruent pairs. These modulations were evident in sighted and blind individuals. Notably, distractor effects were overall far smaller in blind than in sighted participants, despite comparable target-distractor identification performance. Thus, the absence of developmental vision seems to be associated with an increased ability to focus tactile attention towards a non-spatially defined target. Nevertheless, that blind individuals exhibited effects of hand posture and task instructions in their congruency effects suggests that, like the sighted, they automatically integrate anatomical and external information during tactile localization. Moreover, spatial integration in tactile processing is, thus, flexibly

  16. Sharing the responsibility for driver distraction across road transport systems: a systems approach to the management of distracted driving.

    PubMed

    Young, Kristie L; Salmon, Paul M

    2015-01-01

    Distracted driving is acknowledged universally as a large and growing road safety problem. Compounding the problem is that distracted driving is a complex, multifaceted issue influenced by a multitude of factors, organisations and individuals. As such, management of the problem is not straightforward. Numerous countermeasures have been developed and implemented across the globe. The vast majority of these measures have derived from the traditional reductionist, driver-centric approach to distraction and have failed to fully reflect the complex mix of actors and components that give rise to drivers becoming distracted. An alternative approach that is gaining momentum in road safety is the systems approach, which considers all components of the system and their interactions as an integrated whole. In this paper, we review the current knowledge base on driver distraction and argue that the systems approach is not currently being realised in practice. Adopting a more holistic, systems approach to distracted driving will not only improve existing knowledge and interventions from the traditional approach, but will enhance our understanding and management of distraction by considering the complex relationships and interactions of the multiple actors and the myriad sources, enablers and interventions that make up the distracted driving system. It is only by recognising and understanding how all of the system components work together to enable distraction to occur, that we can start to work on solutions to help mitigate the occurrence and consequences of distracted driving. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Vibrotactile pattern recognition: a portable compact tactile matrix.

    PubMed

    Thullier, Francine; Bolmont, Benoît; Lestienne, Francis G

    2012-02-01

    Compact tactile matrix (CTM) is a vibrotactile device composed of a seven-by-seven array of electromechanical vibrators "tactip" used to represent tactile patterns applied to a small skin area. The CTM uses a dynamic feature to generate spatiotemporal tactile patterns. The design requirements focus particularly on maximizing the transmission of the vibration from one tactip to the others as well as to the skin over a square area of 16 cm (2) while simultaneously minimizing the transmission of vibrations throughout the overall structure of the CTM. Experiments were conducted on 22 unpracticed subjects to evaluate how the CTM could be used to develop a tactile semantics for communication of instructions in order to test the ability of the subjects to identify: 1) directional prescriptors for gesture guidance and 2) instructional commands for operational task requirements in a military context. The results indicate that, after familiarization, recognition accuracies in the tactile patterns were remarkably precise for more 80% of the subjects. © 2011 IEEE

  18. Minimum distraction gap: how much ankle joint space is enough in ankle distraction arthroplasty?

    PubMed

    Fragomen, Austin T; McCoy, Thomas H; Meyers, Kathleen N; Rozbruch, S Robert

    2014-02-01

    The success of ankle distraction arthroplasty relies on the separation of the tibiotalar articular surfaces. The purpose of this study was to find the minimum distraction gap needed to ensure that the tibiotalar joint surfaces would not contact each other with full weight-bearing while under distraction. Circular external fixators were mounted to nine cadaver ankle specimens. Each specimen was then placed into a custom-designed load chamber. Loads of 0, 350, and 700N were applied to the specimen. Radiographic joint space was measured and joint contact pressure was monitored under each load. The external fixator was then sequentially distracted, and the radiographic joint space was measured under the three different loads. The experiment was stopped when there was no joint contact under 700N of load. The radiographic joint space was measured and the initial (undistracted) radiographic joint space was subtracted from it yielding the distraction gap. The minimum distraction gap (mDG) that would provide total unloading was calculated. The average mDG was 2.4 mm (range, 1.6 to 4.0 mm) at 700N of load, 4.4 mm (range, 3.7 to 5.8 mm) at 350N of load, and 4.9 mm (range, 3.7 to 7.0 mm) at 0N of load. These results suggest that if the radiographic joint space of on a standing X-ray of an ankle undergoing distraction arthroplasty shows a minimum of 5.8 mm of DG, then there will be no contact between joint surfaces during full weight-bearing. Therefore, 5 mm of radiographic joint space, as recommended historically, may not be adequate to prevent contact of the articular surfaces during weight-bearing.

  19. Midface distraction osteogenesis: internal vs. external devices.

    PubMed

    Meling, T R; Høgevold, H-E; Due-Tønnessen, B J; Skjelbred, P

    2011-02-01

    This study compares internal and external distraction devices in the treatment of midface retrusion. 20 patients were treated with midface distraction (12 Crouzon, 4 Apert, 4 others); 12 with internal distraction (MID device), 8 with external distraction (Red or Blue device). The two groups were compared regarding operation time, peroperative blood loss and complications. The groups were comparable regarding patient age, sex, weight and diagnosis. In the MID-group, 7 of 12 patients (58%) underwent Le Fort III, 5 underwent 12 monobloc (32%). In the Blue device group, three of eight patients underwent Le Fort II (38%), three of eight underwent Le Fort III (38%), and two of eight underwent monobloc (25%). Operation time was shorter in the Blue device (mean 298 min) than in the MID group (mean 354 min). Peroperative blood loss and complication rates were similar. The internal distraction device is the 'gold standard' for treating midface retrusion. The use of an external distraction device in midface distraction osteogenesis is associated with a shorter operation time; peroperative blood loss and complications were similar. An external device affords better 3-dimensional control during the distraction process, so external distraction is preferable in patients who will tolerate this treatment. Copyright © 2010 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. A roadside study of observable driver distractions.

    PubMed

    Sullman, Mark J M; Prat, Francesc; Tasci, Duygu Kuzu

    2015-01-01

    This study investigated the prevalence of observable distractions while driving and the effect of drivers' characteristics and time-related variables on their prevalence. Using roadside observation, 2 independent observers collected data at 4 randomly selected locations in St. Albans, UK. Of the 10,984 drivers observed, 16.8% were engaged in a secondary task, with talking to passengers being the most common distraction (8.8%), followed by smoking (1.9%) and talking on a hands-free mobile phone (1.7%). An additional 1.0% were observed talking on a handheld phone, and the rest of the distractions (e.g., texting, drinking) were recorded in less than 1% of the drivers observed. Gender-related differences were found for a number of different distractions (i.e., talking to passengers, drinking, and handheld mobile phone conversations), but age emerged as a significant predictor for most secondary tasks, including talking to passengers, smoking, hands-free mobile phone use, handheld mobile phone use, texting/keying numbers, drinking, and engagement in any type of distraction (all distractions combined). The overall pattern for age was that middle-aged and older drivers were less likely to be distracted than younger drivers. This work provides further evidence of the relatively high rate of distracted driving in the UK. The findings clearly indicate that younger drivers are more likely to drive distracted, which probably contributes to their higher crash rates.

  1. Speech-Language Dissociations, Distractibility, and Childhood Stuttering

    PubMed Central

    Conture, Edward G.; Walden, Tedra A.; Lambert, Warren E.

    2015-01-01

    Purpose This study investigated the relation among speech-language dissociations, attentional distractibility, and childhood stuttering. Method Participants were 82 preschool-age children who stutter (CWS) and 120 who do not stutter (CWNS). Correlation-based statistics (Bates, Appelbaum, Salcedo, Saygin, & Pizzamiglio, 2003) identified dissociations across 5 norm-based speech-language subtests. The Behavioral Style Questionnaire Distractibility subscale measured attentional distractibility. Analyses addressed (a) between-groups differences in the number of children exhibiting speech-language dissociations; (b) between-groups distractibility differences; (c) the relation between distractibility and speech-language dissociations; and (d) whether interactions between distractibility and dissociations predicted the frequency of total, stuttered, and nonstuttered disfluencies. Results More preschool-age CWS exhibited speech-language dissociations compared with CWNS, and more boys exhibited dissociations compared with girls. In addition, male CWS were less distractible than female CWS and female CWNS. For CWS, but not CWNS, less distractibility (i.e., greater attention) was associated with more speech-language dissociations. Last, interactions between distractibility and dissociations did not predict speech disfluencies in CWS or CWNS. Conclusions The present findings suggest that for preschool-age CWS, attentional processes are associated with speech-language dissociations. Future investigations are warranted to better understand the directionality of effect of this association (e.g., inefficient attentional processes → speech-language dissociations vs. inefficient attentional processes ← speech-language dissociations). PMID:26126203

  2. Anterior ankle arthroscopy, distraction or dorsiflexion?

    PubMed

    de Leeuw, Peter A J; Golanó, Pau; Clavero, Joan A; van Dijk, C Niek

    2010-05-01

    Anterior ankle arthroscopy can basically be performed by two different methods; the dorsiflexion- or distraction method. The objective of this study was to determine the size of the anterior working area for both the dorsiflexion and distraction method. The anterior working area is anteriorly limited by the overlying anatomy which includes the neurovascular bundle. We hypothesize that in ankle dorsiflexion the anterior neurovascular bundle will move away anteriorly from the ankle joint, whereas in ankle distraction the anterior neurovascular bundle is pulled tight towards the joint, thereby decreasing the safe anterior working area. Six fresh frozen ankle specimens, amputated above the knee, were scanned with computed tomography. Prior to scanning the anterior tibial artery was injected with contrast fluid and subsequently each ankle was scanned both in ankle dorsiflexion and in distraction. A special device was developed to reproducibly obtain ankle dorsiflexion and distraction in the computed tomography scanner. The distance between the anterior border of the inferior tibial articular facet and the posterior border of the anterior tibial artery was measured. The median distance from the anterior border of the inferior tibial articular facet to the posterior border of the anterior tibial artery in ankle dorsiflexion and distraction was 0.9 cm (range 0.7-1.5) and 0.7 cm (range 0.5-0.8), respectively. The distance in ankle dorsiflexion significantly exceeded the distance in ankle distraction (P = 0.03). The current study shows a significantly increased distance between the anterior distal tibia and the overlying anterior neurovascular bundle with the ankle in a slightly dorsiflexed position as compared to the distracted ankle position. We thereby conclude that the distracted ankle position puts the neurovascular structures more at risk for iatrogenic damage when performing anterior ankle arthroscopy.

  3. Anterior ankle arthroscopy, distraction or dorsiflexion?

    PubMed Central

    Golanó, Pau; Clavero, Joan A.; van Dijk, C. Niek

    2010-01-01

    Anterior ankle arthroscopy can basically be performed by two different methods; the dorsiflexion- or distraction method. The objective of this study was to determine the size of the anterior working area for both the dorsiflexion and distraction method. The anterior working area is anteriorly limited by the overlying anatomy which includes the neurovascular bundle. We hypothesize that in ankle dorsiflexion the anterior neurovascular bundle will move away anteriorly from the ankle joint, whereas in ankle distraction the anterior neurovascular bundle is pulled tight towards the joint, thereby decreasing the safe anterior working area. Six fresh frozen ankle specimens, amputated above the knee, were scanned with computed tomography. Prior to scanning the anterior tibial artery was injected with contrast fluid and subsequently each ankle was scanned both in ankle dorsiflexion and in distraction. A special device was developed to reproducibly obtain ankle dorsiflexion and distraction in the computed tomography scanner. The distance between the anterior border of the inferior tibial articular facet and the posterior border of the anterior tibial artery was measured. The median distance from the anterior border of the inferior tibial articular facet to the posterior border of the anterior tibial artery in ankle dorsiflexion and distraction was 0.9 cm (range 0.7–1.5) and 0.7 cm (range 0.5–0.8), respectively. The distance in ankle dorsiflexion significantly exceeded the distance in ankle distraction (P = 0.03). The current study shows a significantly increased distance between the anterior distal tibia and the overlying anterior neurovascular bundle with the ankle in a slightly dorsiflexed position as compared to the distracted ankle position. We thereby conclude that the distracted ankle position puts the neurovascular structures more at risk for iatrogenic damage when performing anterior ankle arthroscopy. PMID:20217392

  4. Real-time edge tracking using a tactile sensor

    NASA Technical Reports Server (NTRS)

    Berger, Alan D.; Volpe, Richard; Khosla, Pradeep K.

    1989-01-01

    Object recognition through the use of input from multiple sensors is an important aspect of an autonomous manipulation system. In tactile object recognition, it is necessary to determine the location and orientation of object edges and surfaces. A controller is proposed that utilizes a tactile sensor in the feedback loop of a manipulator to track along edges. In the control system, the data from the tactile sensor is first processed to find edges. The parameters of these edges are then used to generate a control signal to a hybrid controller. Theory is presented for tactile edge detection and an edge tracking controller. In addition, experimental verification of the edge tracking controller is presented.

  5. Distraction and Mind-Wandering Under Load

    PubMed Central

    Forster, Sophie

    2013-01-01

    Attention research over the last several decades has provided rich insights into the determinants of distraction, including distractor characteristics, task features, and individual differences. Load Theory represented a particularly important breakthrough, highlighting the critical role of the level and nature of task-load in determining both the efficiency of distractor rejection and the stage of processing at which this occurs. However, until recently studies of distraction were restricted to those measuring rather specific forms of distraction by external stimuli which I argue that, although intended to be irrelevant, were in fact task-relevant. In daily life, attention may be distracted by a wide range of stimuli, which may often be entirely unrelated to any task being performed, and may include not only external stimuli but also internally generated stimuli such as task-unrelated thoughts. This review outlines recent research examining these more general, entirely task-irrelevant, forms of distraction within the framework of Load Theory. I discuss the relation between different forms of distraction, and the universality of load effects across different distractor types and individuals. PMID:23734138

  6. Distraction and mind-wandering under load.

    PubMed

    Forster, Sophie

    2013-01-01

    Attention research over the last several decades has provided rich insights into the determinants of distraction, including distractor characteristics, task features, and individual differences. Load Theory represented a particularly important breakthrough, highlighting the critical role of the level and nature of task-load in determining both the efficiency of distractor rejection and the stage of processing at which this occurs. However, until recently studies of distraction were restricted to those measuring rather specific forms of distraction by external stimuli which I argue that, although intended to be irrelevant, were in fact task-relevant. In daily life, attention may be distracted by a wide range of stimuli, which may often be entirely unrelated to any task being performed, and may include not only external stimuli but also internally generated stimuli such as task-unrelated thoughts. This review outlines recent research examining these more general, entirely task-irrelevant, forms of distraction within the framework of Load Theory. I discuss the relation between different forms of distraction, and the universality of load effects across different distractor types and individuals.

  7. A low-cost method of craniofacial distraction osteogenesis.

    PubMed

    Greyvensteyn, Gerhardus A; Madaree, Anil

    2016-03-01

    Distraction osteogenesis is an effective treatment modality for the correction of craniofacial deformities. The cost of these devices is significant and may preclude routine use of these distractors in developing countries. Hence, distraction osteogenesis was performed using medical equipment that was readily available in any hospital at minimal cost. From 2008 to 2013, a retrospective study was performed on infants and neonates who underwent primary distraction for craniofacial abnormalities. Midface or mandibular distraction was performed because of respiratory impairment and/or globe exposure. The apparatus used included Steinmann pins, stainless steel wires, attachment bolts, orthopaedic pulleys, string and intravenous bags for weights. For midface distraction, a transzygomatic pin was inserted, and a transmandibular pin or a cerclage wire was inserted into the mandible through the symphysis or body of the mandible and connected to the pulley system. Distraction osteogenesis was performed on five patients - three mandibular distractions (Pierre Robin sequence) and two transfacial distractions (Apert syndrome/Pfeiffer syndrome type III). The mean age, duration of distraction and duration of consolidation at the time of distraction was 60.5 days, 18.6 days and 16.4 days, respectively. The mean length of distraction achieved was 12 mm. Common complications observed were pin loosening, pressure necrosis of the skin and uneven pull. A major disadvantage was the longer hospital stay required. The African method of distraction is effective, easy and cost effective and could be used in third-world hospitals where surgical expertise or expensive distraction sets are not freely available. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Predicting Visual Distraction Using Driving Performance Data

    PubMed Central

    Kircher, Katja; Ahlstrom, Christer

    2010-01-01

    Behavioral variables are often used as performance indicators (PIs) of visual or internal distraction induced by secondary tasks. The objective of this study is to investigate whether visual distraction can be predicted by driving performance PIs in a naturalistic setting. Visual distraction is here defined by a gaze based real-time distraction detection algorithm called AttenD. Seven drivers used an instrumented vehicle for one month each in a small scale field operational test. For each of the visual distraction events detected by AttenD, seven PIs such as steering wheel reversal rate and throttle hold were calculated. Corresponding data were also calculated for time periods during which the drivers were classified as attentive. For each PI, means between distracted and attentive states were calculated using t-tests for different time-window sizes (2 – 40 s), and the window width with the smallest resulting p-value was selected as optimal. Based on the optimized PIs, logistic regression was used to predict whether the drivers were attentive or distracted. The logistic regression resulted in predictions which were 76 % correct (sensitivity = 77 % and specificity = 76 %). The conclusion is that there is a relationship between behavioral variables and visual distraction, but the relationship is not strong enough to accurately predict visual driver distraction. Instead, behavioral PIs are probably best suited as complementary to eye tracking based algorithms in order to make them more accurate and robust. PMID:21050615

  9. Unfavourable results with distraction in craniofacial skeleton

    PubMed Central

    Agarwal, Rajiv

    2013-01-01

    Distraction osteogenesis has revolutionised the management of craniofacial abnormalities. The technique however requires precise planning, patient selection, execution and follow-up to achieve consistent and positive results and to avoid unfavourable results. The unfavourable results with craniofacial distraction stem from many factors ranging from improper patient selection, planning and use of inappropriate distraction device and vector. The present study analyses the current standards and techniques of distraction and details in depth the various errors and complications that may occur due to this technique. The commonly observed complications of distraction have been detailed along with measures and suggestions to avoid them in clinical practice. PMID:24501455

  10. Rigid external maxillary distraction and rhinoplasty for pyknodysostosis.

    PubMed

    Varol, Altan; Sabuncuoglu, Fidan Alakus; Sencimen, Metin; Akcam, Timur; Olmez, Hüseyin; Basa, Selçuk

    2011-05-01

    This article reports the treatment of an 33-year-old female patient with pyknodysostosis by rigid external distraction II midface distraction system. The patient with pyknodysostosis described in this report had severe midfacial hypoplasia. Correction of this by use of routine orthognathic surgery would require osteosynthesis and bone grafting. Risk of infection and/or nonunion after such a surgical procedure was considered too great, and therefore the possibility of treatment by distraction osteogenesis of the maxilla was evaluated. The rigid external distraction II midface distraction system was used to relocate the hypoplastic maxilla at anterior-inferior projection. Distraction osteogenesis should be considered as the primary reconstructive method for maxillofacial deformities in patients with sclerosing bone dysplasias, since this is the second reported case treated successfully with rigid external distraction.

  11. Piezoelectric Polymer Tactile Sensor Arrays for Robotics.

    DTIC Science & Technology

    1987-12-01

    response to slow and fast stimuli (Dario and others, 1984:2). The touch receptors relate tactile information through a variety of tactile sensory...flexure. The only occurrence when an evaporated electrode broke (and became intermit - tently open circuited) was during the measurement of the PPTSA *4

  12. Vibratory tactile display for textures

    NASA Technical Reports Server (NTRS)

    Ikei, Yasushi; Ikeno, Akihisa; Fukuda, Shuichi

    1994-01-01

    We have developed a tactile display that produces vibratory stimulus to a fingertip in contact with a vibrating tactor matrix. The display depicts tactile surface textures while the user is exploring a virtual object surface. A piezoelectric actuator drives the individual tactor in accordance with both the finger movement and the surface texture being traced. Spatiotemporal display control schemes were examined for presenting the fundamental surface texture elements. The temporal duration of vibratory stimulus was experimentally optimized to simulate the adaptation process of cutaneous sensation. The selected duration time for presenting a single line edge agreed with the time threshold of tactile sensation. Then spatial stimulus disposition schemes were discussed for representation of other edge shapes. As an alternative means not relying on amplitude control, a method of augmented duration at the edge was investigated. Spatial resolution of the display was measured for the lines presented both in perpendicular and parallel to a finger axis. Discrimination of texture density was also measured on random dot textures.

  13. Development of a Remodeled Caspar Retractor and Its Application in the Measurement of Distractive Resistance in an In Vitro Anterior Cervical Distraction Model.

    PubMed

    Wen, Junxiang; Xu, Jianwei; Li, Lijun; Yang, Mingjie; Pan, Jie; Chen, Deyu; Jia, Lianshun; Tan, Jun

    2017-06-01

    In vitro biomechanical study of the cervical intervertebral distraction using a remodeled Caspar retractor. To investigate the torques required for distraction to different heights in an in vitro C3-C4 anterior cervical distraction model using a remodeled Caspar retractor, focusing on the influence of the intervertebral disk, posterior longitudinal ligament (PLL), and ligamentum flavum (LF). No previous studies have reported on the torques required for distraction to various heights or the factors resisting distraction in anterior cervical discectomy and fusion. Anterior cervical distractions at C3-C4 was performed in 6 cadaveric specimens using a remodeled Caspar retractor, under 4 conditions: A, before disk removal; B, after disk removal; C, after disk and PLL removal; and D, after disk and PLL removal and cutting of the LF. Distraction was performed for 5 teeth, and distractive torque of each tooth was recorded. The torque increased with distraction height under all conditions. There was a sudden increase in torque at the fourth tooth under conditions B and C, but not D. Under condition A, distraction to the third tooth required 84.8±13.3 cN m. Under conditions B and C, distraction to the third tooth required <13 cN m, and further distraction required dramatically increased torque. Under condition D, no marked increase in torque was recorded. Distraction of the intervertebral space was much easier after disk removal. An intact LF caused a sudden marked increase in the force required for distraction, possibly indicating the point at which the LF was fully stretched. This increase in resistance may help to determine the optimal distraction height to avoid excessive stress to the endplate spacer. The remodeled Caspar retractor in the present study may provide a feasible and convenient method for intraoperative measurement of distractive resistance.

  14. Endoscopic vs. tactile evaluation of subgingival calculus.

    PubMed

    Osborn, Joy B; Lenton, Patricia A; Lunos, Scott A; Blue, Christine M

    2014-08-01

    Endoscopic technology has been developed to facilitate imagery for use during diagnostic and therapeutic phases of periodontal care. The purpose of this study was to compare the level of subgingival calculus detection using a periodontal endoscope with that of conventional tactile explorer in periodontitis subjects. A convenience sample of 26 subjects with moderate periodontitis in at least 2 quadrants was recruited from the University of Minnesota School of Dentistry to undergo quadrant scaling and root planing. One quadrant from each subject was randomized for tactile calculus detection alone and the other quadrant for tactile detection plus the Perioscope ™ (Perioscopy Inc., Oakland, Cali). A calculus index on a 0 to 3 score was performed at baseline and at 2 post-scaling and root planing visits. Sites where calculus was detected at visit 1 were retreated. T-tests were used to determine within-subject differences between Perioscope™ and tactile measures, and changes in measures between visits. Significantly more calculus was detected using the Perioscope™ vs. tactile explorer for all 3 subject visits (p<0.005). Mean changes (reduction) in calculus detection from baseline to visit 1 were statistically significant for both the Perioscope™ and tactile quadrants (p<0.0001). However, further reductions in calculus detection from visit 1 to visit 2 was only significant for the Perioscope™ quadrant (p<0.025), indicating that this methodology was able to more precisely detect calculus at this visit. It was concluded that the addition of a visual component to calculus detection via the Perioscope™ was most helpful in the re-evaluation phase of periodontal therapy. Copyright © 2014 The American Dental Hygienists’ Association.

  15. Rapid maxillary distraction protocol utilizing the halo distraction system and rigid internal fixation.

    PubMed

    Baker, Stephen B; Reid, Russell R; Burkey, Brooke; Bartlett, Scott P

    2007-09-01

    To shorten head frame wear time associated with external halo distraction (HD), we have adapted a protocol for maxillary distraction with the halo system that integrates plate fixation. All patients had a history of cleft lip and/or palate and maxillary retrusion > or = 8 mm. Five patients treated with this protocol and followed for at least 1 year were included in this study. The protocol included a 3-day latency period, variable maxillary distraction, and removal of the halo device with simultaneous rigid internal fixation. Two patients had a variable period of maxillomandibular fixation (MMF), which maintained the maxillary advancement and idealized intercuspal position while permitting further callus maturation. Cephalographs were obtained preoperatively, immediately following distractor removal, and 1 year after rigid internal fixation. The mean age at time of surgery was 18.7 years. The maxillary deficiency ranged from 8 to 15 mm (mean = 10.6 mm). All five patients demonstrated excellent occlusion. Cephalometric analysis 1-year post rigid internal fixation revealed minimal (<1 mm) skeletal relapse. Rapid maxillary distraction followed by MMF to maintain maxillary advancement may reduce halo device wear to 1 to 2 weeks. MMF optimizes occlusion by forcing the maxillary teeth into maximal intercuspal position. Rigid fixation is not only associated with less long-term relapse compared to nonrigid forms of fixation, but also minimizes the incidence of nonunion. This treatment protocol provides the advancement possible with distraction osteogenesis and the accuracy of orthognathic surgery, thereby minimizing external head frame wear.

  16. Merkel cells transduce and encode tactile stimuli to drive Aβ-afferent impulses

    PubMed Central

    Ikeda, Ryo; Cha, Myeounghoon; Ling, Jennifer; Jia, Zhanfeng; Coyle, Dennis; Gu, Jianguo G.

    2014-01-01

    SUMMARY Sensory systems for detecting tactile stimuli have evolved from touch-sensing nerves in invertebrates to complicated tactile end-organs in mammals. Merkel discs are tactile end-organs consisting of Merkel cells and Aβ-afferent nerve endings, and are localized in fingertips, whisker hair follicles and other touch-sensitive spots. Merkel discs transduce touch into slowly adapting impulses to enable tactile discrimination, but their transduction and encoding mechanisms remain unknown. Using rat whisker hair follicles, we show that Merkel cells rather than Aβ-afferent nerve endings are primary sites of tactile transduction, and identify the Piezo2 ion channel as the Merkel cell mechanical transducer. Piezo2 transduces tactile stimuli into Ca2+-action potentials in Merkel cells, which drive Aβ-afferent nerve endings to fire slowly adapting impulses. We further demonstrate that Piezo2 and Ca2+-action potentials in Merkel cells are required for behavioral tactile responses. Our findings provide insights into how tactile end-organs function and have clinical implications for tactile dysfunctions. PMID:24746027

  17. [Three-dimensional modeling of mandibular distraction].

    PubMed

    Morgon, L A; Trunde, F; Coudert, J L; Disant, F

    2003-12-01

    Facial hemi-atrophy affects 1 in 4000 or 5000 children. We propose treating this deformation of the 1st branchial arch with the "bone distraction" lengthening technique first described by Ilizarov in the 1950s, which has already been employed with the mandible. We have modelled mandibular distraction in facial hemi-atrophy patients and discuss the benefits of such pre-surgical planning encompassing the assistance of pre- and post-operative as well as surgically coordinated orthodontic therapy. Using X scanner views of a 5 year-old girl patient, we have developed a distraction-simulation software, which makes the pathological side harmonious with the healthy side along the medial sagittal plane. In order to obtain facial symmetry, put bones in balance, and orient the occlusal plane horizontally, essential requisites of occlusal stability, it is necessary: to employ a 2 or 3-dimensional distractor, to pre-plan the distraction and screw positioning, to set up a fixed orthodontic treatment plan prior to beginning distraction therapy.

  18. Sustained efficacy of virtual reality distraction.

    PubMed

    Rutter, Charles E; Dahlquist, Lynnda M; Weiss, Karen E

    2009-04-01

    The current study tested whether the effectiveness of distraction using virtual reality (VR) technology in reducing cold pressor pain would maintain over the course of 8 weekly exposures. Twenty-eight adults, 18 to 23 years of age, underwent 1 baseline cold pressor trial and 1 VR distraction trial in randomized order each week. VR distraction led to significant increases in pain threshold and pain tolerance and significant decreases in pain intensity, time spent thinking about pain, and self-reported anxiety, relative to baseline. Repeated exposure did not appear to affect the benefits of VR. Implications for the long-term use of VR distraction as a nonpharmacological analgesic are discussed. This article addresses the concern that the efficacy of virtual reality-assisted distraction from pain could potentially decrease with repeated exposure. The current finding that efficacy did not diminish over several repeated exposures provides support for the use of virtual reality as an adjuvant treatment of pain.

  19. Tactile priming modulates the activation of the fronto-parietal circuit during tactile angle match and non-match processing: an fMRI study

    PubMed Central

    Yang, Jiajia; Yu, Yinghua; Kunita, Akinori; Huang, Qiang; Wu, Jinglong; Sawamoto, Nobukatsu; Fukuyama, Hidenao

    2014-01-01

    The repetition of a stimulus task reduces the neural activity within certain cortical regions responsible for working memory (WM) processing. Although previous evidence has shown that repeated vibrotactile stimuli reduce the activation in the ventrolateral prefrontal cortex, whether the repeated tactile spatial stimuli triggered the priming effect correlated with the same cortical region remains unclear. Therefore, we used event-related functional magnetic resonance imaging (fMRI) and a delayed match-to-sample task to investigate the contributions of the priming effect to tactile spatial WM processing. Fourteen healthy volunteers were asked to encode three tactile angle stimuli during the encoding phase and one tactile angle stimulus during the recognition phase. Then, they answered whether the last angle stimulus was presented during the encoding phase. As expected, both the Match and Non-Match tasks activated a similar cerebral network. The critical new finding was decreased brain activity in the left inferior frontal gyrus (IFG), the right posterior parietal cortex (PPC) and bilateral medial frontal gyri (mFG) for the match task compared to the Non-Match task. Therefore, we suggest that the tactile priming engaged repetition suppression mechanisms during tactile angle matching, and this process decreased the activation of the fronto-parietal circuit, including IFG, mFG and PPC. PMID:25566010

  20. Biomechanical analysis of cervical distraction.

    PubMed

    Miller, L S; Cotler, H B; De Lucia, F A; Cotler, J M; Hume, E L

    1987-11-01

    A biomechanical analysis of cervical distraction is presented, and a model comparing closed reduction of cervical spine dislocations to spring mechanics is developed. Behavior of a spring may be described as F = k delta x where F = distraction force; delta x = elongation of the spring; and k = spring constant. The records and roentgenograms of 24 cervical spine dislocations were reviewed retrospectively. Evaluation of cervical distraction vs traction weight indicates that Ftraction = kneck delta x; where F = traction weight and x = distraction at the injured level. The constant, kneck, is different for bilateral and unilateral dislocations (P less than .001) and is a function of magnitude of injury and neck morphology. As determined in this study, traction weight needed for reduction of facet dislocations may be estimated using the formulae: Ftx = 107.1 lbs/cm (x) unilateral, and Ftx = 76.4 lbs/cm (x) bilateral.

  1. Tactile mental body parts representation in obesity.

    PubMed

    Scarpina, Federica; Castelnuovo, Gianluca; Molinari, Enrico

    2014-12-30

    Obese people׳s distortions in visually-based mental body-parts representations have been reported in previous studies, but other sensory modalities have largely been neglected. In the present study, we investigated possible differences in tactilely-based body-parts representation between an obese and a healthy-weight group; additionally we explore the possible relationship between the tactile- and the visually-based body representation. Participants were asked to estimate the distance between two tactile stimuli that were simultaneously administered on the arm or on the abdomen, in the absence of visual input. The visually-based body-parts representation was investigated by a visual imagery method in which subjects were instructed to compare the horizontal extension of body part pairs. According to the results, the obese participants overestimated the size of the tactilely-perceived distances more than the healthy-weight group when the arm, and not the abdomen, was stimulated. Moreover, they reported a lower level of accuracy than did the healthy-weight group when estimating horizontal distances relative to their bodies, confirming an inappropriate visually-based mental body representation. Our results imply that body representation disturbance in obese people is not limited to the visual mental domain, but it spreads to the tactilely perceived distances. The inaccuracy was not a generalized tendency but was body-part related. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Sustained Efficacy of Virtual Reality Distraction

    PubMed Central

    Rutter, Charles E.; Dahlquist, Lynnda M.; Weiss, Karen E.

    2011-01-01

    The current study tested whether the effectiveness of distraction using virtual reality (VR) technology in reducing cold pressor pain would maintain over the course of eight weekly exposures. Twenty-eight adults, 18 to 23 years of age, underwent one baseline cold pressor trial and one VR distraction trial in randomized order each week. VR distraction led to significant increases in pain threshold and pain tolerance, and significant decreases in pain intensity, time spent thinking about pain, and self-reported anxiety, relative to baseline. Repeated exposure did not appear to affect the benefits of VR. Implications for the long-term use of VR distraction as a non-pharmacological analgesic are discussed. PMID:19231295

  3. Artificial tactile sensing in minimally invasive surgery - a new technical approach.

    PubMed

    Schostek, Sebastian; Ho, Chi-Nghia; Kalanovic, Daniel; Schurr, Marc O

    2006-01-01

    The loss of tactile sensation is a commonly known drawback of minimally invasive surgery (MIS). Since the advent of MIS, research activities in providing tactile information to the surgeon are still ongoing, in order to improve patient safety and to extend the indications for MIS. We have designed a tactile sensor system comprising a tactile laparoscopic grasper for surgical palpation. For this purpose, we developed a novel tactile sensor technology which allows the manufacturing of an integrated sensor array within an acceptable price range. The array was integrated into the jaws of a 10mm laparoscopic grasper. The tactile data are transferred wirelessly via Bluetooth and are presented visually to the surgeon. The goal was to be able to obtain information about the shape and consistency of tissue structures by gently compressing the tissue between the jaws of the tactile instrument and thus to be able to recognize and assess anatomical or pathological structures, even if they are hidden in the tissue. With a prototype of the tactile sensor system we have conducted bench-tests as well as in-vitro and in-vivo experiments. The system proved feasibility in an experimental environment, it was easy to use, and the novel tactile sensor array was applicable for both palpation and grasping manoeuvres with forces of up to 60N. The tactile data turned out to be a useful supplement to the minimal amount of haptic feedback that is provided by current endoscopic instruments and the endoscopic image under certain conditions.

  4. Tactile roughness perception in the presence of olfactory and trigeminal stimulants

    PubMed Central

    Koijck, Lara A.; Van Erp, Jan B.F.

    2015-01-01

    Previous research has shown that odorants consistently evoke associations with textures and their tactile properties like smoothness and roughness. Also, it has been observed that olfaction can modulate tactile perception. We therefore hypothesized that tactile roughness perception may be biased towards the somatosensory connotation of an ambient odorant. We performed two experiments to test this hypothesis. In the first experiment, we investigated the influence of ambient chemosensory stimuli with different roughness connotations on tactile roughness perception. In addition to a pleasant odor with a connotation of softness (PEA), we also included a trigeminal stimulant with a rough, sharp or prickly connotation (Ethanol). We expected that—compared to a No-odorant control condition—tactile texture perception would be biased towards smoothness in the presence of PEA and towards roughness in the presence of Ethanol. However, our results show no significant interaction between chemosensory stimulation and perceived tactile surface roughness. It could be argued that ambient odors may be less effective in stimulating crossmodal associations, since they are by definition extraneous to the tactile stimuli. In an attempt to optimize the conditions for sensory integration, we therefore performed a second experiment in which the olfactory and tactile stimuli were presented in synchrony and in close spatial proximity. In addition, we included pleasant (Lemon) and unpleasant (Indole) odorants that are known to have the ability to affect tactile perception. We expected that tactile stimuli would be perceived as less rough when simultaneously presented with Lemon or PEA (both associated with softness) than when presented with Ethanol or Indole (odors that can be associated with roughness). Again, we found no significant main effect of chemosensory condition on perceived tactile roughness. We discuss the limitations of this study and we present suggestions for future research

  5. Distraction to treat knee osteoarthritis.

    PubMed

    Flouzat-Lachaniette, Charles-Henri; Roubineau, François; Heyberger, Clémence; Bouthors, Charlie

    2017-03-01

    The objective of this article is to review data on joint distraction used to treat knee osteoarthritis. Joint distraction is a surgical procedure in which the two bony ends of the joint are gradually pulled apart then kept separated for 2 months in an external fixation frame. Weight bearing is continued to ensure variations in hydrostatic pressure within the joint. In published studies, joint distraction provided substantial clinical and structural improvements in patients with knee osteoarthritis, delaying joint replacement surgery for at least 2 years. Animal studies showed that joint distraction was associated with decrease in the secondary inflammatory response, cartilage breakdown, and subchondral bone remodeling. In vitro, the intermittent application of hydrostatic pressure stimulated the production of extracellular matrix, particularly in joints with osteoarthritis. Nevertheless, several considerations invite caution when considering the more widespread use of joint distraction. Published studies have short follow-ups and small sample sizes. In addition, the high frequency of pin tract infection is of concern, since most patients eventually require knee replacement surgery. These two considerations indicate a need for longer-term prospective studies of patient cohorts. Copyright © 2016 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  6. Microfabricated Tactile Sensors for Biomedical Applications: A Review

    PubMed Central

    Saccomandi, Paola; Schena, Emiliano; Oddo, Calogero Maria; Zollo, Loredana; Silvestri, Sergio; Guglielmelli, Eugenio

    2014-01-01

    During the last decades, tactile sensors based on different sensing principles have been developed due to the growing interest in robotics and, mainly, in medical applications. Several technological solutions have been employed to design tactile sensors; in particular, solutions based on microfabrication present several attractive features. Microfabrication technologies allow for developing miniaturized sensors with good performance in terms of metrological properties (e.g., accuracy, sensitivity, low power consumption, and frequency response). Small size and good metrological properties heighten the potential role of tactile sensors in medicine, making them especially attractive to be integrated in smart interfaces and microsurgical tools. This paper provides an overview of microfabricated tactile sensors, focusing on the mean principles of sensing, i.e., piezoresistive, piezoelectric and capacitive sensors. These sensors are employed for measuring contact properties, in particular force and pressure, in three main medical fields, i.e., prosthetics and artificial skin, minimal access surgery and smart interfaces for biomechanical analysis. The working principles and the metrological properties of the most promising tactile, microfabricated sensors are analyzed, together with their application in medicine. Finally, the new emerging technologies in these fields are briefly described. PMID:25587432

  7. A Pneumatic Tactile Sensor for Co-Operative Robots

    PubMed Central

    He, Rui; Yu, Jianjun; Zuo, Guoyu

    2017-01-01

    Tactile sensors of comprehensive functions are urgently needed for the advanced robot to co-exist and co-operate with human beings. Pneumatic tactile sensors based on air bladder possess some noticeable advantages for human-robot interaction application. In this paper, we construct a pneumatic tactile sensor and apply it on the fingertip of robot hand to realize the sensing of force, vibration and slippage via the change of the pressure of the air bladder, and we utilize the sensor to perceive the object’s features such as softness and roughness. The pneumatic tactile sensor has good linearity, repeatability and low hysteresis and both its size and sensing range can be customized by using different material as well as different thicknesses of the air bladder. It is also simple and cheap to fabricate. Therefore, the pneumatic tactile sensor is suitable for the application of co-operative robots and can be widely utilized to improve the performance of service robots. We can apply it to the fingertip of the robot to endow the robotic hand with the ability to co-operate with humans and handle the fragile objects because of the inherent compliance of the air bladder. PMID:29125565

  8. Microfabricated tactile sensors for biomedical applications: a review.

    PubMed

    Saccomandi, Paola; Schena, Emiliano; Oddo, Calogero Maria; Zollo, Loredana; Silvestri, Sergio; Guglielmelli, Eugenio

    2014-12-01

    During the last decades, tactile sensors based on different sensing principles have been developed due to the growing interest in robotics and, mainly, in medical applications. Several technological solutions have been employed to design tactile sensors; in particular, solutions based on microfabrication present several attractive features. Microfabrication technologies allow for developing miniaturized sensors with good performance in terms of metrological properties (e.g., accuracy, sensitivity, low power consumption, and frequency response). Small size and good metrological properties heighten the potential role of tactile sensors in medicine, making them especially attractive to be integrated in smart interfaces and microsurgical tools. This paper provides an overview of microfabricated tactile sensors, focusing on the mean principles of sensing, i.e., piezoresistive, piezoelectric and capacitive sensors. These sensors are employed for measuring contact properties, in particular force and pressure, in three main medical fields, i.e., prosthetics and artificial skin, minimal access surgery and smart interfaces for biomechanical analysis. The working principles and the metrological properties of the most promising tactile, microfabricated sensors are analyzed, together with their application in medicine. Finally, the new emerging technologies in these fields are briefly described.

  9. Review of Recent Inkjet-Printed Capacitive Tactile Sensors

    PubMed Central

    Salim, Ahmed

    2017-01-01

    Inkjet printing is an advanced printing technology that has been used to develop conducting layers, interconnects and other features on a variety of substrates. It is an additive manufacturing process that offers cost-effective, lightweight designs and simplifies the fabrication process with little effort. There is hardly sufficient research on tactile sensors and inkjet printing. Advancements in materials science and inkjet printing greatly facilitate the realization of sophisticated tactile sensors. Starting from the concept of capacitive sensing, a brief comparison of printing techniques, the essential requirements of inkjet-printing and the attractive features of state-of-the art inkjet-printed tactile sensors developed on diverse substrates (paper, polymer, glass and textile) are presented in this comprehensive review. Recent trends in inkjet-printed wearable/flexible and foldable tactile sensors are evaluated, paving the way for future research. PMID:29125584

  10. Effects of distraction on memory and cognition: a commentary.

    PubMed

    Craik, Fergus I M

    2014-01-01

    This commentary is a review of the findings and ideas reported in the preceding nine articles on the effects of distraction on aspects of cognitive performance. The articles themselves deal with the disruptive effects of distraction on recall of words, objects and events, also on visual processing, category formation and other cognitive tasks. The commentary assesses the part played by "domain-general" suppression of distracting information and the "domain-specific" competition arising when tasks and distraction involve very similar material. Some forms of distraction are meaningfully relevant to the ongoing task, and Treisman's (1964) model of selective attention is invoked to provide an account of findings in this area. Finally, individual differences to vulnerability to distraction are discussed; older adults are particularly affected by distracting stimuli although the failure to repress distraction can sometimes prove beneficial to later cognitive performance.

  11. Unmyelinated tactile cutaneous nerves signal erotic sensations.

    PubMed

    Jönsson, Emma H; Backlund Wasling, Helena; Wagnbeck, Vicktoria; Dimitriadis, Menelaos; Georgiadis, Janniko R; Olausson, Håkan; Croy, Ilona

    2015-06-01

    Intrapersonal touch is a powerful tool for communicating emotions and can among many things evoke feelings of eroticism and sexual arousal. The peripheral neural mechanisms of erotic touch signaling have been less studied. C tactile afferents (unmyelinated low-threshold mechanoreceptors), known to underpin pleasant aspects of touch processing, have been posited to play an important role. In two studies, we investigated the relationship between C tactile activation and the perception of erotic and pleasant touch, using tactile brushing stimulation. In total, 66 healthy subjects (37 women, age range 19-51 years) were examined. In study 1 (n = 20), five different stroking velocities were applied to the forearm and the inner thigh. The participants answered questions about partnership, mood, and touch. In study 2 (n = 46), the same five stroking velocities were applied to the forearm. The participants answered questions about partnership, touch, and sexuality. Both touch eroticism and pleasantness were rated significantly higher for C tactile optimal velocities compared with suboptimal velocities. No difference was found between the ratings of the thigh and the forearm. The velocity-dependent rating curves of pleasantness, intensity, and eroticism differed from each other. Pleasantness was best explained by a quadratic fit, intensity by a linear fit, and eroticism by both. A linear transformation of pleasantness and intensity predicted the observed eroticism ratings reliably. Eroticism ratings were negatively correlated with length of relationship. Touch was rated most erotic when perceived as pleasant and weak. In human hairy skin, perception of pleasantness is correlated with the firing rate of C tactile afferents, and perception of intensity is correlated with the firing rate of Aβ afferents. Accordingly, eroticism may be perceived most readily for touch stimuli that induce high activity in C tactile fibers and low activity in Aβ fibers. © 2015 International

  12. Texture- and deformability-based surface recognition by tactile image analysis.

    PubMed

    Khasnobish, Anwesha; Pal, Monalisa; Tibarewala, D N; Konar, Amit; Pal, Kunal

    2016-08-01

    Deformability and texture are two unique object characteristics which are essential for appropriate surface recognition by tactile exploration. Tactile sensation is required to be incorporated in artificial arms for rehabilitative and other human-computer interface applications to achieve efficient and human-like manoeuvring. To accomplish the same, surface recognition by tactile data analysis is one of the prerequisites. The aim of this work is to develop effective technique for identification of various surfaces based on deformability and texture by analysing tactile images which are obtained during dynamic exploration of the item by artificial arms whose gripper is fitted with tactile sensors. Tactile data have been acquired, while human beings as well as a robot hand fitted with tactile sensors explored the objects. The tactile images are pre-processed, and relevant features are extracted from the tactile images. These features are provided as input to the variants of support vector machine (SVM), linear discriminant analysis and k-nearest neighbour (kNN) for classification. Based on deformability, six household surfaces are recognized from their corresponding tactile images. Moreover, based on texture five surfaces of daily use are classified. The method adopted in the former two cases has also been applied for deformability- and texture-based recognition of four biomembranes, i.e. membranes prepared from biomaterials which can be used for various applications such as drug delivery and implants. Linear SVM performed best for recognizing surface deformability with an accuracy of 83 % in 82.60 ms, whereas kNN classifier recognizes surfaces of daily use having different textures with an accuracy of 89 % in 54.25 ms and SVM with radial basis function kernel recognizes biomembranes with an accuracy of 78 % in 53.35 ms. The classifiers are observed to generalize well on the unseen test datasets with very high performance to achieve efficient material

  13. Displaying Sensed Tactile Cues with a Fingertip Haptic Device.

    PubMed

    Pacchierotti, Claudio; Prattichizzo, Domenico; Kuchenbecker, Katherine J

    2015-01-01

    Telerobotic systems enable humans to explore and manipulate remote environments for applications such as surgery and disaster response, but few such systems provide the operator with cutaneous feedback. This article presents a novel approach to remote cutaneous interaction; our method is compatible with any fingertip tactile sensor and any mechanical tactile display device, and it does not require a position/force or skin deformation model. Instead, it directly maps the sensed stimuli to the best possible input commands for the device's motors using a data set recorded with the tactile sensor inside the device. As a proof of concept, we considered a haptic system composed of a BioTac tactile sensor, in charge of measuring contact deformations, and a custom 3-DoF cutaneous device with a flat contact platform, in charge of applying deformations to the user's fingertip. To validate the proposed approach and discover its inherent tradeoffs, we carried out two remote tactile interaction experiments. The first one evaluated the error between the tactile sensations registered by the BioTac in a remote environment and the sensations created by the cutaneous device for six representative tactile interactions and 27 variations of the display algorithm. The normalized average errors in the best condition were 3.0 percent of the BioTac's full 12-bit scale. The second experiment evaluated human subjects' experiences for the same six remote interactions and eight algorithm variations. The average subjective rating for the best algorithm variation was 8.2 out of 10, where 10 is best.

  14. MEMS tactile display: from fabrication to characterization

    NASA Astrophysics Data System (ADS)

    Miki, Norihisa; Kosemura, Yumi; Watanabe, Junpei; Ishikawa, Hiroaki

    2014-03-01

    We report fabrication and characterization of MEMS-based tactile display that can display users various tactile information, such as Braille codes and surface textures. The display consists of 9 micro-actuators that are equipped with hydraulic displacement amplification mechanism (HDAM) to achieve large enough displacement to stimulate the human tactile receptors. HDAM encapsulates incompressible liquids. We developed a liquid encapsulation process, which we termed as Bonding-in-Liquid Technique, where bonding with a UV-curable resin in glycerin is conducted in the liquid, which prevented interfusion of air bubbles and deformation of the membrane during the bonding. HDAM successfully amplified the displacement generated by piezoelectric actuators by a factor of 6. The display could virtually produce "rough" and "smooth" surfaces, by controlling the vibration frequency, displacement, and the actuation periods of an actuator until the adjacent actuator was driven. We introduced a sample comparison method to characterize the surfaces, which involves human tactile sensation. First, we prepared samples whose mechanical properties are known. We displayed a surface texture to the user by controlling the parameters and then, the user selects a sample that has the most similar surface texture. By doing so, we can correlate the parameters with the mechanical properties of the sample as well as find the sets of the parameters that can provide similar tactile information to many users. The preliminary results with respect to roughness and hardness is presented.

  15. A Single Session of Mirror-based Tactile and Motor Training Improves Tactile Dysfunction in Children with Unilateral Cerebral Palsy: A Replicated Randomized Controlled Case Series.

    PubMed

    Auld, Megan L; Johnston, Leanne M; Russo, Remo N; Moseley, G Lorimer

    2017-10-01

    This replicated randomized controlled crossover case series investigated the effect of mirror-based tactile and motor training on tactile registration and perception in children with unilateral cerebral palsy (UCP). Six children with UCP (6-18 years; median 10 years, five male, three-left hemiplegia, four-manual ability classification system (MACS) I, one MACS II and one MACS III) participated. They attended two 90-minute sessions - one of mirror-based training and one of standard practice, bimanual therapy - in alternated order. Tactile registration (Semmes Weinstein Monofilaments) and perception (double simultaneous or single-point localization) were assessed before and after each session. Change was estimated using reliable change index (RCI). Tactile perception improved in four participants (RCI > 1.75), with mirror-based training, but was unchanged with bimanual therapy (RCI < 1.0 for all participants). Neither intervention affected tactile registration. Mirror-based training demonstrates potential to improve tactile perception in children with UCP. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. ALCOHOL AND DISTRACTION INTERACT TO IMPAIR DRIVING PERFORMANCE

    PubMed Central

    Harrison, Emily L. R.; Fillmore, Mark T.

    2011-01-01

    Background Recognition of the risks associated with alcohol intoxication and driver distraction has led to a wealth of simulated driving research aimed at studying the adverse effects of each of these factors. Research on driving has moved beyond the individual, separate examination of these factors to the examination of potential interactions between alcohol intoxication and driver distraction. In many driving situations, distractions are commonplace and might have little or no disruptive influence on primary driving functions. Yet, such distractions might become disruptive to a driver who is intoxicated. Methods The present study examined the interactive impairing effects of alcohol intoxication and driver distraction on simulated driving performance in 40 young adult drivers using a divided attention task as a distracter activity. The interactive influence of alcohol and distraction was tested by having drivers perform the driving task under four different conditions: 0.65 g/kg alcohol; 0.65 g/kg alcohol + divided attention; placebo; and placebo + divided attention. Results As hypothesized, divided attention had no impairing effect on driving performance in sober drivers. However, under alcohol, divided attention exacerbated the impairing effects of alcohol on driving precision. Conclusions Alcohol and distraction continue to be appropriate targets for research into ways to reduce the rates of driving-related fatalities and injuries. Greater consideration of how alcohol and distraction interact to impair aspects of driving performance can further efforts to create prevention and intervention measures to protect drivers, particularly young adults. PMID:21277119

  17. Alcohol and distraction interact to impair driving performance.

    PubMed

    Harrison, Emily L R; Fillmore, Mark T

    2011-08-01

    Recognition of the risks associated with alcohol intoxication and driver distraction has led to a wealth of simulated driving research aimed at studying the adverse effects of each of these factors. Research on driving has moved beyond the individual, separate examination of these factors to the examination of potential interactions between alcohol intoxication and driver distraction. In many driving situations, distractions are commonplace and might have little or no disruptive influence on primary driving functions. Yet, such distractions might become disruptive to a driver who is intoxicated. The present study examined the interactive impairing effects of alcohol intoxication and driver distraction on simulated driving performance in 40 young adult drivers using a divided attention task as a distracter activity. The interactive influence of alcohol and distraction was tested by having drivers perform the driving task under four different conditions: 0.65 g/kg alcohol; 0.65 g/kg alcohol+divided attention; placebo; and placebo+divided attention. As hypothesized, divided attention had no impairing effect on driving performance in sober drivers. However, under alcohol, divided attention exacerbated the impairing effects of alcohol on driving precision. Alcohol and distraction continue to be appropriate targets for research into ways to reduce the rates of driving-related fatalities and injuries. Greater consideration of how alcohol and distraction interact to impair aspects of driving performance can further efforts to create prevention and intervention measures to protect drivers, particularly young adults. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  18. Tactile Data Entry System

    NASA Technical Reports Server (NTRS)

    Adams, Richard J.

    2015-01-01

    The patent-pending Glove-Enabled Computer Operations (GECO) design leverages extravehicular activity (EVA) glove design features as platforms for instrumentation and tactile feedback, enabling the gloves to function as human-computer interface devices. Flexible sensors in each finger enable control inputs that can be mapped to any number of functions (e.g., a mouse click, a keyboard strike, or a button press). Tracking of hand motion is interpreted alternatively as movement of a mouse (change in cursor position on a graphical user interface) or a change in hand position on a virtual keyboard. Programmable vibro-tactile actuators aligned with each finger enrich the interface by creating the haptic sensations associated with control inputs, such as recoil of a button press.

  19. Relaxation and Distraction in Experimental Desensitization.

    ERIC Educational Resources Information Center

    Weir, R. O.; Marshall, W. L.

    1980-01-01

    Compared experimental desensitization with a procedure that replaced relaxation with a distraction task and with an approach that combined both relaxation and distraction. Desensitization generally was more effective than the other two procedures. (Author)

  20. Tactile texture and friction of soft sponge surfaces.

    PubMed

    Takahashi, Akira; Suzuki, Makoto; Imai, Yumi; Nonomura, Yoshimune

    2015-06-01

    We evaluated the tactile texture and frictional properties of five soft sponges with various cell sizes. The frictional forces were measured by a friction meter containing a contact probe with human-finger-like geometry and mechanical properties. When the subjects touched these sponges with their fingers, hard-textured sponges were deemed unpleasant. This tactile feeling changed with friction factors including friction coefficients, their temporal patterns, as well as mechanical and shape factors. These findings provide useful information on how to control the tactile textures of various sponges. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Differential effects of tactile high- and low-frequency stimulation on tactile discrimination in human subjects.

    PubMed

    Ragert, Patrick; Kalisch, Tobias; Bliem, Barbara; Franzkowiak, Stephanie; Dinse, Hubert R

    2008-01-23

    Long-term potentiation (LTP) and long-term depression (LTD) play important roles in mediating activity-dependent changes in synaptic transmission and are believed to be crucial mechanisms underlying learning and cortical plasticity. In human subjects, however, the lack of adequate input stimuli for the induction of LTP and LTD makes it difficult to study directly the impact of such protocols on behavior. Using tactile high- and low-frequency stimulation protocols in humans, we explored the potential of such protocols for the induction of perceptual changes. We delivered tactile high-frequency and low-frequency stimuli (t-HFS, t-LFS) to skin sites of approximately 50 mm2 on the tip of the index finger. As assessed by 2-point discrimination, we demonstrate that 20 minutes of t-HFS improved tactile discrimination, while t-LFS impaired performance. T-HFS-effects were stable for at least 24 hours whereas t-LFS-induced changes recovered faster. While t-HFS changes were spatially very specific with no changes on the neighboring fingers, impaired tactile performance after t-LFS was also observed on the right middle-finger. A central finding was that for both t-LFS and t-HFS perceptual changes were dependent on the size of the stimulated skin area. No changes were observed when the stimulated area was very small (< 1 mm2) indicating special requirements for spatial summation. Our results demonstrate differential effects of such protocols in a frequency specific manner that might be related to LTP- and LTD-like changes in human subjects.

  2. Dynamics of Driver Distraction: The process of engaging and disengaging

    PubMed Central

    Lee, John D.

    2014-01-01

    Driver distraction research has a long history, spanning nearly 50 years, but intensifying over the last decade. The dominant paradigm guiding this research defines distraction in terms of excessive workload and limited attentional resources. This approach largely ignores how drivers come to engage in these tasks and under what conditions they engage and disengage from driving—the dynamics of distraction. The dynamics of distraction identifies breakdowns of interruption management as an important contributor to distraction, leading to describe distraction in terms of failures of task timing, switching, and prioritization. The dynamics of distraction also identifies disengagement in driving (e.g., mind wandering) as a substantial challenge that secondary tasks might exacerbate or mitigate. Increasing vehicle automation accentuates the need to consider these dynamics of distraction. Automation offers drivers more opportunity to engage in distractions and disengage from driving, and can surprise drivers by unexpectedly requiring drivers to quickly re-engage in driving—placing greater importance of interruption management expertise. This review describes distraction in terms of breakdowns in interruption management and problems of engagement, and summarizes how contingency, conditioning, and consequence traps lead to problems of engaging and disengaging in driving and distractions. PMID:24776224

  3. Gender differences in the content of cognitive distraction during sex.

    PubMed

    Meana, Marta; Nunnink, Sarah E

    2006-02-01

    This study compared 220 college men and 237 college women on two types of self-reported cognitive distraction during sex, performance- and appearance-based. Affect, psychological distress, sexual knowledge, attitudes, fantasies, experiences, body image, satisfaction, and sexual function were assessed with the Derogatis Sexual Functioning Inventory and the Sexual History Form to determine associations with distraction. Between-gender analyses revealed that women reported higher levels of overall and appearance-based distraction than did men, but similar levels of performance-based distraction. Within-gender analyses revealed that women reported as much of one type of distraction as the other, while men reported more performance- than appearance-based distraction. In women, appearance-based distraction was predicted by negative body image, psychological distress, and not being in a relationship, while performance-based distraction was predicted by negative body image, psychological distress, and sexual dissatisfaction. In men, appearance-based distraction was predicted by negative body image, sexual dissatisfaction and not being in a relationship, while performance-based distraction was predicted by negative body image and sexual dissatisfaction. Investigating the content of cognitive distraction may be useful in understanding gender differences in sexual experience and in refining cognitive components of sex therapy.

  4. Impact of distracted driving on congestion.

    DOT National Transportation Integrated Search

    2011-03-01

    Studies have documented a link between distracted driving and diminished safety; however, an association : between distracted driving and traffic congestion has not been investigated in depth. The present study : examined the behavior of teens and yo...

  5. The impact of distraction mitigation strategies on driving performance.

    PubMed

    Donmez, Birsen; Boyle, Linda Ng; Lee, John D

    2006-01-01

    An experiment was conducted to assess the effects of distraction mitigation strategies on drivers' performance and productivity while engaged in an in-vehicle information system task. Previous studies show that in-vehicle tasks undermine driver safety and there is a need to mitigate driver distraction. An advising strategy that alerts drivers to potential dangers and a locking strategy that prevents the driver from continuing the distracting task were presented to 16 middle-aged and 12 older drivers in a driving simulator in two modes (auditory, visual) and two road conditions (curves, braking events). Distraction was a problem for both age groups. Visual distractions were more detrimental than auditory ones for curve negotiation, as depicted by more erratic steering, F (6, 155) = 26.76, p < .05. Drivers did brake more abruptly under auditory distractions, but this effect was mitigated by both the advising, t (155) = 8.37, p < .05, and locking strategies, t (155) = 8.49, p < .05. The locking strategy also resulted in longer minimum time to collision for middle-aged drivers engaged in visual distractions, F (6, 138) = 2.43, p < .05. Adaptive interfaces can reduce abrupt braking on curve entries resulting from auditory distractions and can also improve the braking response for distracted drivers. These strategies can be incorporated into existing in-vehicle systems, thus mitigating the effects of distraction and improving driver performance.

  6. Neural Basis of Visual Distraction

    ERIC Educational Resources Information Center

    Kim, So-Yeon; Hopfinger, Joseph B.

    2010-01-01

    The ability to maintain focus and avoid distraction by goal-irrelevant stimuli is critical for performing many tasks and may be a key deficit in attention-related problems. Recent studies have demonstrated that irrelevant stimuli that are consciously perceived may be filtered out on a neural level and not cause the distraction triggered by…

  7. Tactile Radar: experimenting a computer game with visually disabled.

    PubMed

    Kastrup, Virgínia; Cassinelli, Alvaro; Quérette, Paulo; Bergstrom, Niklas; Sampaio, Eliana

    2017-09-18

    Visually disabled people increasingly use computers in everyday life, thanks to novel assistive technologies better tailored to their cognitive functioning. Like sighted people, many are interested in computer games - videogames and audio-games. Tactile-games are beginning to emerge. The Tactile Radar is a device through which a visually disabled person is able to detect distal obstacles. In this study, it is connected to a computer running a tactile-game. The game consists in finding and collecting randomly arranged coins in a virtual room. The study was conducted with nine congenital blind people including both sexes, aged 20-64 years old. Complementary methods of first and third person were used: the debriefing interview and the quasi-experimental design. The results indicate that the Tactile Radar is suitable for the creation of computer games specifically tailored for visually disabled people. Furthermore, the device seems capable of eliciting a powerful immersive experience. Methodologically speaking, this research contributes to the consolidation and development of first and third person complementary methods, particularly useful in disabled people research field, including the evaluation by users of the Tactile Radar effectiveness in a virtual reality context. Implications for rehabilitation Despite the growing interest in virtual games for visually disabled people, they still find barriers to access such games. Through the development of assistive technologies such as the Tactile Radar, applied in virtual games, we can create new opportunities for leisure, socialization and education for visually disabled people. The results of our study indicate that the Tactile Radar is adapted to the creation of video games for visually disabled people, providing a playful interaction with the players.

  8. Changes in speech following maxillary distraction osteogenesis.

    PubMed

    Guyette, T W; Polley, J W; Figueroa, A; Smith, B E

    2001-05-01

    The purpose of this study was to describe changes in articulation and velopharyngeal function following maxillary distraction osteogenesis. This is a descriptive, post hoc clinical report comparing the performance of patients before and after maxillary distraction. The independent variable was maxillary distraction while the dependent variables were resonance, articulation errors, and velopharyngeal function. The data were collected at a tertiary health care center in Chicago. The data from pre- and postoperative evaluations of 18 maxillary distraction patients were used. The outcome measures were severity of hypernasality and hyponasality, velopharyngeal orifice size as estimated using the pressure-flow technique, and number and type of articulation errors. At the long-term follow-up, 16.7% exhibited a significant increase in hypernasality. Seventy-five percent of patients with preoperative hyponasality experienced improved nasal resonance. Articulation improved in 67% of patients by the 1-year follow-up. In a predominately cleft palate population, the risk for velopharyngeal insufficiency following maxillary distraction is similar to the risk observed in Le Fort I maxillary advancement. Patients being considered for maxillary distraction surgery should receive pre- and postoperative speech evaluations and be counseled about risks for changes in their speech.

  9. Arthroscopic ankle arthrodesis with intra-articular distraction.

    PubMed

    Kim, Hyong Nyun; Jeon, June Young; Noh, Kyu Cheol; Kim, Hong Kyun; Dong, Quanyu; Park, Yong Wook

    2014-01-01

    Arthroscopic ankle arthrodesis has shown high rates of union comparable to those with open arthrodesis but with substantially less postoperative morbidity, shorter operative times, less blood loss, and shorter hospital stays. To easily perform arthroscopic resection of the articular cartilage, sufficient distraction of the joint is necessary to insert the arthroscope and instruments. However, sometimes, standard noninvasive ankle distraction will not be sufficient in post-traumatic ankle arthritis, with the development of arthrofibrosis and joint contracture after severe ankle trauma. In the present report, we describe a technique to distract the ankle joint by inserting a 4.6-mm stainless steel cannula with a blunt trocar inside the joint. The cannula allowed sufficient intra-articular distraction, and, at the same time, a 4.0-mm arthroscope can be inserted through the cannula to view the joint. Screws can be inserted to fix the joint under fluoroscopic guidance without changing the patient's position or removing the noninvasive distraction device and leg holder, which are often necessary during standard arthroscopic arthrodesis with noninvasive distraction. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Graphical tactile displays for visually-impaired people.

    PubMed

    Vidal-Verdú, Fernando; Hafez, Moustapha

    2007-03-01

    This paper presents an up-to-date survey of graphical tactile displays. These devices provide information through the sense of touch. At best, they should display both text and graphics (text may be considered a type of graphic). Graphs made with shapeable sheets result in bulky items awkward to store and transport; their production is expensive and time-consuming and they deteriorate quickly. Research is ongoing for a refreshable tactile display that acts as an output device for a computer or other information source and can present the information in text and graphics. The work in this field has branched into diverse areas, from physiological studies to technological aspects and challenges. Moreover, interest in these devices is now being shown by other fields such as virtual reality, minimally invasive surgery and teleoperation. It is attracting more and more people, research and money. Many proposals have been put forward, several of them succeeding in the task of presenting tactile information. However, most are research prototypes and very expensive to produce commercially. Thus the goal of an efficient low-cost tactile display for visually-impaired people has not yet been reached.

  11. RETENTION OF HIGH TACTILE ACUITY THROUGHOUT THE LIFESPAN IN BLINDNESS

    PubMed Central

    Legge, Gordon E.; Madison, Cindee; Vaughn, Brenna N.; Cheong, Allen M.Y.; Miller, Joseph C.

    2009-01-01

    Previous studies of tactile acuity on the fingertip using passive touch have demonstrated an age-related decline in spatial resolution for both sighted and blind subjects. We have re-examined this age dependence with two newly designed tactile-acuity charts requiring active exploration of the test symbols. One chart used dot patterns similar to Braille and the other used embossed Landolt rings. Groups of blind Braille readers and sighted subjects, ranging in age from 12 to 85 years, were tested in two experiments. We replicated previous findings for sighted subjects by showing an age related decrease in tactile acuity by nearly 1% per year. Surprisingly, the blind subjects retained high acuity into old age showing no age-related decline. For the blind subjects, tactile acuity did not correlate with braille reading speed, the amount of daily reading, or the age at which braille was learned. We conclude that when measured with active touch, blind subjects retain high tactile acuity into old age, unlike their aging sighted peers. We propose that blind people's use of active touch in daily activities, not specifically Braille reading, results in preservation of tactile acuity across the lifespan. PMID:19064491

  12. To what extent do Gestalt grouping principles influence tactile perception?

    PubMed

    Gallace, Alberto; Spence, Charles

    2011-07-01

    Since their formulation by the Gestalt movement more than a century ago, the principles of perceptual grouping have primarily been investigated in the visual modality and, to a lesser extent, in the auditory modality. The present review addresses the question of whether the same grouping principles also affect the perception of tactile stimuli. Although, to date, only a few studies have explicitly investigated the existence of Gestalt grouping principles in the tactile modality, we argue that many more studies have indirectly provided evidence relevant to this topic. Reviewing this body of research, we argue that similar principles to those reported previously in visual and auditory studies also govern the perceptual grouping of tactile stimuli. In particular, we highlight evidence showing that the principles of proximity, similarity, common fate, good continuation, and closure affect tactile perception in both unimodal and crossmodal settings. We also highlight that the grouping of tactile stimuli is often affected by visual and auditory information that happen to be presented simultaneously. Finally, we discuss the theoretical and applied benefits that might pertain to the further study of Gestalt principles operating in both unisensory and multisensory tactile perception.

  13. Measurement of Distraction Force in Cleft Lip and Palate Patients During Le Fort I Maxillary Advancement With Rigid External Distraction.

    PubMed

    Sawada, Hiromi; Ogawa, Takuya; Kataoka, Keiichi; Baba, Yoshiyuki; Moriyama, Keiji

    2017-03-01

    Maxillary distraction osteogenesis (DO) is a mainstream surgical technique for patients who have severe maxillary hypoplasia associated with craniofacial syndromes and cleft-related deformities. However, limited information about the biomechanical aspects of maxillary DO is available limiting broad utilization and improvements to the procedure. The objective of this study was to analyze force levels during the active distraction process and to investigate the relationship between distraction force and maxillary movement during Le Fort I maxillary DO using a rigid external distraction (RED) system. Microtension gauges were integrated into the distraction wires on each side of the RED system. Six patients with cleft lip and palate aged 12.8 to 23.5 years underwent strain gauge measurements during maxillary advancement with DO using an RED system. Lateral cephalograms were taken to measure maxillary horizontal, vertical, and linear movements after DO. The average linear maxillary movement was 11.2 mm (range 8.5-15.9 mm). The applied forces ranged from 13.4 to 26.8 N. The distance of maxillary movement was proportional to the distraction force. The measurement of distraction forces during DO provides important information with which to establish appropriate protocols. Patients requiring more advancement may require more distraction force. However, other factors such as scarring, patient anatomy, surgical freedom of the osteotomized maxilla, and the like, may affect the required force during DO with the RED system.

  14. Blindness enhances tactile acuity and haptic 3-D shape discrimination.

    PubMed

    Norman, J Farley; Bartholomew, Ashley N

    2011-10-01

    This study compared the sensory and perceptual abilities of the blind and sighted. The 32 participants were required to perform two tasks: tactile grating orientation discrimination (to determine tactile acuity) and haptic three-dimensional (3-D) shape discrimination. The results indicated that the blind outperformed their sighted counterparts (individually matched for both age and sex) on both tactile tasks. The improvements in tactile acuity that accompanied blindness occurred for all blind groups (congenital, early, and late). However, the improvements in haptic 3-D shape discrimination only occurred for the early-onset and late-onset blindness groups; the performance of the congenitally blind was no better than that of the sighted controls. The results of the present study demonstrate that blindness does lead to an enhancement of tactile abilities, but they also suggest that early visual experience may play a role in facilitating haptic 3-D shape discrimination.

  15. Mandibular distraction osteogenesis with newly designed electromechanical distractor.

    PubMed

    Aykan, Andac; Ugurlutan, Rifat; Zor, Fatih; Ozturk, Serdar

    2014-07-01

    The purposes of this study were to design a fully automatic electromechanical distractor for continuous mandibular distraction osteogenesis and to investigate the efficacy of this newly developed distractor on sheep mandible model. Five sheep underwent unilateral mandibular osteotomy, and the mechanical component of electromechanical distractor was fixed on both sides of the osteotomy site using pins. After a 5-day latency period, the electromechanical distractor was activated at a rate of 0.30 mm per 8 hours using an electronic control unit. The bone was lengthened for 20 days without any intervention to the electromechanical distractor. The animals were killed on the sixth week of the consolidation period, and 5 distracted mandibles were examined through macroscopic observation and computed tomography. Distracted bone length was measured through computed tomography on sagittal slices. The device was tolerated by the distraction process without complications in all animals. New callus formation was observed on the distraction gap. Radiologic evaluation showed new callus formation in the distraction gap. New callus length was found to be, in average, 18.28 mm. In this preliminary study, a newly designed electromechanical distractor was successfully used for mandible distraction, which mainly provided a continuous lengthening during activation period spontaneously without any intervention. We think that the clinical application of this electromechanic distractor may provide patient comfort during distraction. Moreover, electromechanical distractor has the potential for high-resolution movement capacity when compared with annual distraction. The promising results from this prototype are encouraging to further investigations for human applications.

  16. Two-stage distraction lengthening of the forearm.

    PubMed

    Taghinia, Amir H; Al-Sheikh, Ayman A; Panossian, Andre E; Upton, Joseph

    2013-01-01

    Single-stage lengthening of the forearm using callus distraction is well described; however, forearm lengthening using a 2-stage technique of distraction followed by bone grafting has received less attention. A 2-staged technique can be a better alternative in cases where the surgeon desires extensive lengthening. A retrospective review was undertaken of eleven 2-stage forearm lengthening procedures performed by 1 surgeon over a 15-year period. Indications were radial longitudinal deficiency (8 patients), neonatal ischemic contractures (2 patients), and septic growth arrest (1 patient). Average follow-up was 2.8 years. Distraction was performed on patients an average of 82 mm over an average duration of 24 weeks. Average time to union from the time of distractor removal and grafting was 87 days. Average healing index was 32.1 d/cm. Distraction problems were common and related to the length of time that the distractor was in place; they included pain, pin-related infections, and multiple mechanical device difficulties. Three patients had nonunion, and another had delayed union; however, additional procedures resulted in ultimate bony union in all patients. Demineralized bone matrix and autologous corticocancellous bone grafts yielded predictable healing and good functional results in short-distance distractions. For longer distractions, free vascularized fibula transfer produced the best outcomes. Intercalary cortical allografts did not heal well. Patients with neonatal Volkmann contractures had the most difficulty with distraction and healing, ultimately obtaining little to no lengthening and poor functional outcomes.

  17. The neural bases of distracter-resistant working memory

    PubMed Central

    Wager, Tor D.; Spicer, Julie; Insler, Rachel; Smith, Edward E.

    2014-01-01

    A major difference between humans and other animals is our capacity to maintain information in working memory (WM) while performing secondary tasks, which enables sustained, complex cognition. A common assumption is that the lateral prefrontal cortex (PFC) is critical for WM performance in the presence of distracters, but direct evidence is scarce. We assessed the relationship between fMRI activity and WM performance within-subjects, with performance matched across Distracter and No-distracter conditions. Activity in ventrolateral PFC during WM encoding and maintenance positively predicted performance in both conditions, whereas activity in the pre-supplementary motor area (pre-SMA) predicted performance only under distraction. Other parts of dorsolateral and ventrolateral PFC predicted performance only in the No-distracter condition. These findings challenge a lateral PFC-centered view of distracter-resistance, and suggest that the lateral PFC supports a type of WM representation that is efficient for dealing with task-irrelevant input but is nonetheless easily disrupted by dual-task demands. PMID:24366656

  18. Synthetic and Bio-Artificial Tactile Sensing: A Review

    PubMed Central

    Lucarotti, Chiara; Oddo, Calogero Maria; Vitiello, Nicola; Carrozza, Maria Chiara

    2013-01-01

    This paper reviews the state of the art of artificial tactile sensing, with a particular focus on bio-hybrid and fully-biological approaches. To this aim, the study of physiology of the human sense of touch and of the coding mechanisms of tactile information is a significant starting point, which is briefly explored in this review. Then, the progress towards the development of an artificial sense of touch are investigated. Artificial tactile sensing is analysed with respect to the possible approaches to fabricate the outer interface layer: synthetic skin versus bio-artificial skin. With particular respect to the synthetic skin approach, a brief overview is provided on various technologies and transduction principles that can be integrated beneath the skin layer. Then, the main focus moves to approaches characterized by the use of bio-artificial skin as an outer layer of the artificial sensory system. Within this design solution for the skin, bio-hybrid and fully-biological tactile sensing systems are thoroughly presented: while significant results have been reported for the development of tissue engineered skins, the development of mechanotransduction units and their integration is a recent trend that is still lagging behind, therefore requiring research efforts and investments. In the last part of the paper, application domains and perspectives of the reviewed tactile sensing technologies are discussed. PMID:23348032

  19. Comparison of measurement methods for capacitive tactile sensors and their implementation

    NASA Astrophysics Data System (ADS)

    Tarapata, Grzegorz; Sienkiewicz, Rafał

    2015-09-01

    This paper presents a review of ideas and implementations of measurement methods utilized for capacity measurements in tactile sensors. The paper describes technical method, charge amplification method, generation and as well integration method. Three selected methods were implemented in dedicated measurement system and utilised for capacitance measurements of ourselves made tactile sensors. The tactile sensors tested in this work were fully fabricated with the inkjet printing technology. The tests result were presented and summarised. The charge amplification method (CDC) was selected as the best method for the measurement of the tactile sensors.

  20. The Effects of Extravehicular Activity (EVA) Glove Pressure on Tactility

    NASA Technical Reports Server (NTRS)

    Thompson, Shelby; Miranda, Mesloh; England, Scott; Benson, Elizabeth; Rajulu, Sudhakar

    2010-01-01

    The purpose of the current study was to quantify finger tactility, while wearing a Phase VI Extravehicular Activity (EVA) glove. Subjects were fully suited in an Extravehicular Mobility Unit (EMU) suit. Data was collected under three conditions: bare-handed, gloved at 0 psi, and gloved at 4.3 psi. In order to test tactility, a series of 30 tactile stimuli (bumps) were created that varied in both height and width. With the hand obscured, subjects applied pressure to each bump until detected tactilely. The amount of force needed to detect each bump was recorded using load cells located under a force-plate. The amount of force needed to detect a bump was positively related to width, but inversely related to height. In addition, as the psi of the glove increased, more force was needed to detect the bump. In terms of application, it was possible to determine the optimal width and height a bump needs to be for a specific amount of force applied for tactility.

  1. Audio-tactile integration and the influence of musical training.

    PubMed

    Kuchenbuch, Anja; Paraskevopoulos, Evangelos; Herholz, Sibylle C; Pantev, Christo

    2014-01-01

    Perception of our environment is a multisensory experience; information from different sensory systems like the auditory, visual and tactile is constantly integrated. Complex tasks that require high temporal and spatial precision of multisensory integration put strong demands on the underlying networks but it is largely unknown how task experience shapes multisensory processing. Long-term musical training is an excellent model for brain plasticity because it shapes the human brain at functional and structural levels, affecting a network of brain areas. In the present study we used magnetoencephalography (MEG) to investigate how audio-tactile perception is integrated in the human brain and if musicians show enhancement of the corresponding activation compared to non-musicians. Using a paradigm that allowed the investigation of combined and separate auditory and tactile processing, we found a multisensory incongruency response, generated in frontal, cingulate and cerebellar regions, an auditory mismatch response generated mainly in the auditory cortex and a tactile mismatch response generated in frontal and cerebellar regions. The influence of musical training was seen in the audio-tactile as well as in the auditory condition, indicating enhanced higher-order processing in musicians, while the sources of the tactile MMN were not influenced by long-term musical training. Consistent with the predictive coding model, more basic, bottom-up sensory processing was relatively stable and less affected by expertise, whereas areas for top-down models of multisensory expectancies were modulated by training.

  2. Tactile device utilizing a single magnetorheological sponge: experimental investigation

    NASA Astrophysics Data System (ADS)

    Kim, Soomin; Kim, Pyunghwa; Choi, Seung-Hyun; Oh, Jong-Seok; Choi, Seung-Bok

    2015-04-01

    In the field of medicine, several new areas have been currently introduced such as robot-assisted surgery. However, the major drawback of these systems is that there is no tactile communication between doctors and surgical sites. When the tactile system is brought up, telemedicine including telerobotic surgery can be enhanced much more than now. In this study, a new tactile device is designed using a single magnetorhological (MR) sponge cell to realize the sensation of human organs. MR fluids and an open celled polyurethane foam are used to propose the MR sponge cell. The viscous and elastic sensational behaviors of human organs are realized by the MR sponge cell. Before developing the tactile device, tactile sensation according to touch of human fingers are quantified in advance. The finger is then treated as a reduced beam bundle model (BBM) in which the fingertip is comprised of an elastic beam virtually. Under the reduced BBM, when people want to sense an object, the fingertip is investigated by pushing and sliding. Accordingly, while several magnitudes of magnetic fields are applied to the tactile device, normal and tangential reaction forces and bending moment are measured by 6-axis force/torque sensor instead of the fingertip. These measured data are used to compare with soft tissues. It is demonstrated that the proposed MR sponge cell can realize any part of the organ based on the obtained data.

  3. Long-term skeletodental stability of mandibular symphyseal distraction osteogenesis: Tooth-borne vs hybrid distraction appliances.

    PubMed

    Durham, Julia N; King, John W; Robinson, Quinton C; Trojan, Terry M

    2017-03-01

    To evaluate and compare the long-term skeletodental stability of mandibular symphyseal distraction osteogenesis (MSDO) achieved with the use of tooth-borne vs. hybrid distraction appliances. Posttreatment and follow-up orthodontic records were collected for 33 patients. The 14 patients who underwent distraction with a tooth-borne appliance had a mean follow-up of 5.08 years. The 19 patients who underwent distraction with a hybrid appliance had a mean follow-up of 6.07 years. Records included intraoral photographs, study models, postero-anterior cephalometric radiographs, and lateral cephalometric radiographs. Total changes of 16 measurements were analyzed to compare patients who underwent the tooth-borne vs. the hybrid distraction. Both groups shared several similar and significant (P < .05) changes from posttreatment to follow-up records. Cast analysis showed a decrease in intercanine width and arch length and an increase in irregularity index. The postero-anterior cephalometric radiograph showed an increase in the width of the interincisal apices. The lateral cephalometric radiograph showed a decrease in the MP-L1 angle. The only statistically significant difference between the two appliances was the intercentral incisor contact point. Changes found are consistent with those found in untreated and orthodontically treated individuals over time. The long-term changes in the current patient sample can be determined to be expected and acceptable. MSDO is a viable treatment option with the use of either a hybrid or tooth-borne appliance.

  4. Design Methodology for Magnetic Field-Based Soft Tri-Axis Tactile Sensors.

    PubMed

    Wang, Hongbo; de Boer, Greg; Kow, Junwai; Alazmani, Ali; Ghajari, Mazdak; Hewson, Robert; Culmer, Peter

    2016-08-24

    Tactile sensors are essential if robots are to safely interact with the external world and to dexterously manipulate objects. Current tactile sensors have limitations restricting their use, notably being too fragile or having limited performance. Magnetic field-based soft tactile sensors offer a potential improvement, being durable, low cost, accurate and high bandwidth, but they are relatively undeveloped because of the complexities involved in design and calibration. This paper presents a general design methodology for magnetic field-based three-axis soft tactile sensors, enabling researchers to easily develop specific tactile sensors for a variety of applications. All aspects (design, fabrication, calibration and evaluation) of the development of tri-axis soft tactile sensors are presented and discussed. A moving least square approach is used to decouple and convert the magnetic field signal to force output to eliminate non-linearity and cross-talk effects. A case study of a tactile sensor prototype, MagOne, was developed. This achieved a resolution of 1.42 mN in normal force measurement (0.71 mN in shear force), good output repeatability and has a maximum hysteresis error of 3.4%. These results outperform comparable sensors reported previously, highlighting the efficacy of our methodology for sensor design.

  5. Design Methodology for Magnetic Field-Based Soft Tri-Axis Tactile Sensors

    PubMed Central

    Wang, Hongbo; de Boer, Greg; Kow, Junwai; Alazmani, Ali; Ghajari, Mazdak; Hewson, Robert; Culmer, Peter

    2016-01-01

    Tactile sensors are essential if robots are to safely interact with the external world and to dexterously manipulate objects. Current tactile sensors have limitations restricting their use, notably being too fragile or having limited performance. Magnetic field-based soft tactile sensors offer a potential improvement, being durable, low cost, accurate and high bandwidth, but they are relatively undeveloped because of the complexities involved in design and calibration. This paper presents a general design methodology for magnetic field-based three-axis soft tactile sensors, enabling researchers to easily develop specific tactile sensors for a variety of applications. All aspects (design, fabrication, calibration and evaluation) of the development of tri-axis soft tactile sensors are presented and discussed. A moving least square approach is used to decouple and convert the magnetic field signal to force output to eliminate non-linearity and cross-talk effects. A case study of a tactile sensor prototype, MagOne, was developed. This achieved a resolution of 1.42 mN in normal force measurement (0.71 mN in shear force), good output repeatability and has a maximum hysteresis error of 3.4%. These results outperform comparable sensors reported previously, highlighting the efficacy of our methodology for sensor design. PMID:27563908

  6. The phase of prestimulus alpha oscillations affects tactile perception.

    PubMed

    Ai, Lei; Ro, Tony

    2014-03-01

    Previous studies have shown that neural oscillations in the 8- to 12-Hz range influence sensory perception. In the current study, we examined whether both the power and phase of these mu/alpha oscillations predict successful conscious tactile perception. Near-threshold tactile stimuli were applied to the left hand while electroencephalographic (EEG) activity was recorded over the contralateral right somatosensory cortex. We found a significant inverted U-shaped relationship between prestimulus mu/alpha power and detection rate, suggesting that there is an intermediate level of alpha power that is optimal for tactile perception. We also found a significant difference in phase angle concentration at stimulus onset that predicted whether the upcoming tactile stimulus was perceived or missed. As has been shown in the visual system, these findings suggest that these mu/alpha oscillations measured over somatosensory areas exert a strong inhibitory control on tactile perception and that pulsed inhibition by these oscillations shapes the state of brain activity necessary for conscious perception. They further suggest that these common phasic processing mechanisms across different sensory modalities and brain regions may reflect a common underlying encoding principle in perceptual processing that leads to momentary windows of perceptual awareness.

  7. Distracted driving: a neglected epidemic.

    PubMed

    Dildy, Dale W

    2012-10-01

    In 2009, the National Highway Traffic Safety Administration (NHTSA) estimated nearly 6,000 distracted driver fatalities and 515,000 injuries in the United States alone. Distracted driving is a worldwide problem that needs to be addressed. Software is available to disable cell phone usage while driving, but using the advanced technology may require legislation along with a renewed sense of driver responsibility.

  8. Contextual cueing of tactile search is coded in an anatomical reference frame.

    PubMed

    Assumpção, Leonardo; Shi, Zhuanghua; Zang, Xuelian; Müller, Hermann J; Geyer, Thomas

    2018-04-01

    This work investigates the reference frame(s) underlying tactile context memory, a form of statistical learning in a tactile (finger) search task. In this task, if a searched-for target object is repeatedly encountered within a stable spatial arrangement of task-irrelevant distractors, detecting the target becomes more efficient over time (relative to nonrepeated arrangements), as learned target-distractor spatial associations come to guide tactile search, thus cueing attention to the target location. Since tactile search displays can be represented in several reference frames, including multiple external and an anatomical frame, in Experiment 1 we asked whether repeated search displays are represented in tactile memory with reference to an environment-centered or anatomical reference frame. In Experiment 2, we went on examining a hand-centered versus anatomical reference frame of tactile context memory. Observers performed a tactile search task, divided into a learning and test session. At the transition between the two sessions, we introduced postural manipulations of the hands (crossed ↔ uncrossed in Expt. 1; palm-up ↔ palm-down in Expt. 2) to determine the reference frame of tactile contextual cueing. In both experiments, target-distractor associations acquired during learning transferred to the test session when the placement of the target and distractors was held constant in anatomical, but not external, coordinates. In the latter, RTs were even slower for repeated displays. We conclude that tactile contextual learning is coded in an anatomical reference frame. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  9. Tactile Cueing for Target Acquisition and Identification

    DTIC Science & Technology

    2005-09-01

    method of coding tactile information, and the method of presenting elevation information were studied. Results: Subjects were divided into video game experienced...VGP) subjects and non- video game (NVGP) experienced subjects. VGPs showed a significantly lower’ target acquisition time with the 12...that video game players performed better with the highest level of tactile resolution, while non- video game players performed better with simpler pattern and a lower resolution display.

  10. Improvement and decline in tactile discrimination behavior after cortical plasticity induced by passive tactile coactivation.

    PubMed

    Hodzic, Amra; Veit, Ralf; Karim, Ahmed A; Erb, Michael; Godde, Ben

    2004-01-14

    Perceptual learning can be induced by passive tactile coactivation without attention or reinforcement. We used functional MRI (fMRI) and psychophysics to investigate in detail the specificity of this type of learning for different tactile discrimination tasks and the underlying cortical reorganization. We found that a few hours of Hebbian coactivation evoked a significant increase of primary (SI) and secondary (SII) somatosensory cortical areas representing the stimulated body parts. The amount of plastic changes was strongly correlated with improvement in spatial discrimination performance. However, in the same subjects, frequency discrimination was impaired after coactivation, indicating that even maladaptive processes can be induced by intense passive sensory stimulation.

  11. Cooperative processing in primary somatosensory cortex and posterior parietal cortex during tactile working memory.

    PubMed

    Ku, Yixuan; Zhao, Di; Bodner, Mark; Zhou, Yong-Di

    2015-08-01

    In the present study, causal roles of both the primary somatosensory cortex (SI) and the posterior parietal cortex (PPC) were investigated in a tactile unimodal working memory (WM) task. Individual magnetic resonance imaging-based single-pulse transcranial magnetic stimulation (spTMS) was applied, respectively, to the left SI (ipsilateral to tactile stimuli), right SI (contralateral to tactile stimuli) and right PPC (contralateral to tactile stimuli), while human participants were performing a tactile-tactile unimodal delayed matching-to-sample task. The time points of spTMS were 300, 600 and 900 ms after the onset of the tactile sample stimulus (duration: 200 ms). Compared with ipsilateral SI, application of spTMS over either contralateral SI or contralateral PPC at those time points significantly impaired the accuracy of task performance. Meanwhile, the deterioration in accuracy did not vary with the stimulating time points. Together, these results indicate that the tactile information is processed cooperatively by SI and PPC in the same hemisphere, starting from the early delay of the tactile unimodal WM task. This pattern of processing of tactile information is different from the pattern in tactile-visual cross-modal WM. In a tactile-visual cross-modal WM task, SI and PPC contribute to the processing sequentially, suggesting a process of sensory information transfer during the early delay between modalities. © 2015 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  12. Lengthening by distraction osteogenesis in congenital shortening of metacarpals.

    PubMed

    Bulut, Mehmet; Uçar, Bekir Yavuz; Azboy, Ibrahim; Belhan, Oktay; Yilmaz, Erhan; Karakurt, Lokman

    2013-01-01

    The aim of this study was to present the results of seven cases of metacarpal lengthening by distraction osteogenesis and to discuss the ideal daily rate of distraction. Metacarpal lengthening was performed by distraction osteogenesis in the seven metacarpals of four patients (3 females, 1 male; mean age: 14.9 years). A unilateral external fixator was used for lengthening. Lengthening was initiated with a distraction rate of 2x0.5 mm/day in the patient with bilateral involvement of the middle and ring metacarpals. On the tenth day of lengthening, distraction was discontinued due to pain and contracture. Then, distraction was continued with a rate of 2x0.25 mm/day. In all other cases, the distraction rate was 0.5 mm/day. Pre- and postoperative range of motion was measured with a goniometer. Patient satisfaction was evaluated with visual analog scale. The mean pre- and postoperative metacarpal lengths were 34.6 mm (range: 33 to 37) and 49.7 mm (range: 47 to 52), respectively. The mean lengthening achieved was 15.1 mm (range: 14 to 17), while the mean distraction rate was 0.55 mm/day (range: 0.48 to 0.63). No functional loss was observed in the fingers at the final check-up. The patients were happy with the functional and cosmetic results. Distraction osteogenesis is a safe method providing acceptable cosmetic and functional results in patients with congenital metacarpal shortness. The length of metacarpals and muscles that will be affected from lengthening should be considered when determining the daily rate of distraction.

  13. The effect of chronic low back pain on tactile suppression during back movements.

    PubMed

    Van Damme, Stefaan; Van Hulle, Lore; Danneels, Lieven; Spence, Charles; Crombez, Geert

    2014-10-01

    The aim of the present study was to examine whether tactile suppression, the phenomenon whereby tactile perception is suppressed during movement, would occur in the context of back movements. Of particular interest, it was investigated if tactile suppression in the back would be attenuated in those suffering from chronic low back pain. Individuals with chronic low back pain (N = 30) and a matched control group (N = 24) detected tactile stimuli on three possible locations (back, arm, chest) while performing a back or arm movement, or no movement. We hypothesized that the movements would induce tactile suppression, and that this effect would be largest for low-intense stimuli on the moving body part. We further hypothesized that, during back movements, tactile suppression on the back would be less pronounced in the chronic low back pain group than in the control group. The results showed the expected general tactile suppression effects. The hypothesis of back-specific attenuation of tactile suppression in the chronic low back pain group was not supported. However, back-specific tactile suppression in the chronic low back pain group was less pronounced in those who performed the back movements more slowly. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Seeing the body distorts tactile size perception.

    PubMed

    Longo, Matthew R; Sadibolova, Renata

    2013-03-01

    Vision of the body modulates somatosensation, even when entirely non-informative about stimulation. For example, seeing the body increases tactile spatial acuity, but reduces acute pain. While previous results demonstrate that vision of the body modulates somatosensory sensitivity, it is unknown whether vision also affects metric properties of touch, and if so how. This study investigated how non-informative vision of the body modulates tactile size perception. We used the mirror box illusion to induce the illusion that participants were directly seeing their stimulated left hand, though they actually saw their reflected right hand. We manipulated whether participants: (a) had the illusion of directly seeing their stimulated left hand, (b) had the illusion of seeing a non-body object at the same location, or (c) looked directly at their non-stimulated right-hand. Participants made verbal estimates of the perceived distance between two tactile stimuli presented simultaneously to the dorsum of the left hand, either 20, 30, or 40mm apart. Vision of the body significantly reduced the perceived size of touch, compared to vision of the object or of the contralateral hand. In contrast, no apparent changes of perceived hand size were found. These results show that seeing the body distorts tactile size perception. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Re-examining overlap between tactile and visual motion responses within hMT+ and STS

    PubMed Central

    Jiang, Fang; Beauchamp, Michael S.; Fine, Ione

    2015-01-01

    Here we examine overlap between tactile and visual motion BOLD responses within the human MT+ complex. Although several studies have reported tactile responses overlapping with hMT+, many used group average analyses, leaving it unclear whether these responses were restricted to sub-regions of hMT+. Moreover, previous studies either employed a tactile task or passive stimulation, leaving it unclear whether or not tactile responses in hMT+ are simply the consequence of visual imagery. Here we carried out a replication of one of the classic papers finding tactile responses in hMT+ (Hagen et al. 2002). We mapped MT and MST in individual subjects using visual field localizers. We then examined responses to tactile motion on the arm, either presented passively or in the presence of a visual task performed at fixation designed to minimize visualization of the concurrent tactile stimulation. To our surprise, without a visual task, we found only weak tactile motion responses in MT (6% of voxels showing tactile responses) and MST (2% of voxels). With an unrelated visual task designed to withdraw attention from the tactile modality, responses in MST reduced to almost nothing (<1% regions). Consistent with previous results, we did observe tactile responses in STS regions superior and anterior to hMT+. Despite the lack of individual overlap, group averaged responses produced strong spurious overlap between tactile and visual motion responses within hMT+ that resembled those observed in previous studies. The weak nature of tactile responses in hMT+ (and their abolition by withdrawal of attention) suggests that hMT+ may not serve as a supramodal motion processing module. PMID:26123373

  16. Le Fort I distraction using internal devices for maxillary hypoplasia in patients with cleft lip, palate, and alveolus: complications and their prevention and management.

    PubMed

    Mitsukawa, Nobuyuki; Satoh, Kaneshige; Morishita, Tadashi

    2010-09-01

    In recent years, advancement has been made in distraction osteogenesis in the facial area. It has been applied actively to treat maxillary hypoplasia in patients with cleft lip, palate, and alveolus. Le Fort I distraction using internal devices does not lead to disability in daily living, including during the retention period, and has low surgical invasiveness, facile management, and superior aesthetics. Thus, there have been occasional reports on this procedure in recent years. Because an internal device is unidirectional, the greatest disadvantage is the inability to adjust the direction of distraction after its placement. However, past reports have emphasized its advantages, and its complications have rarely been discussed. We performed Le Fort I distraction using internal devices on 15 young patients. Our results showed notable complications in a few cases. When serial cephalometric analysis was performed after maxillary distraction, it demonstrated that the maxilla assumes various three-dimensional distraction morphologies. In particular, cases with insufficient bone grafting of alveolar clefts developed collapse mainly in the alveolar cleft region during postoperative distraction. Mobility and deviation of the maxillary bone fragment occurred. We implemented preventative measures against complications such as using modifications to place the devices parallel on the left and right sides and using a bite splint for distraction. These measures produced improved outcomes, and we describe here the details.

  17. A preliminary investigation of lumbar tactile acuity in yoga practitioners.

    PubMed

    Flaherty, Mary; Connolly, Martin

    2014-01-01

    Tactile acuity in the back relates to voluntary lumbo-pelvic control and is lower in chronic low back pain (CLBP) patients. Two-point discrimination (TPD) thresholds are higher, indicating decreased tactile acuity in patients with CLBP. Yoga has been shown to help relieve CLBP. This study investigated the hypothesis that regular practitioners of yoga have increased tactile acuity (i.e., lower TPD thresholds) when compared to matched controls who regularly perform gym-based (resistance training or aerobic-type) exercise. Tactile acuity in the low back was assessed using TPD in 16 long-term practitioners of yoga (5 Ashtanga, 5 Bikram, and 6 Iyengar practitioners) and 16 age- and gender-matched healthy controls who exercise (with weights and aerobic exercise). The yoga practitioners' TPD was lower than that of the exercisers, indicating greater tactile acuity in the low back. While there was no difference between the TPD of the practitioners of different yoga styles, the TPD of the Ashtanga yoga participants were significantly lower than those of the exercisers. The yogis whose main reasons to practice yoga were for "meditation or increased mindfulness" and for "well-being" showed a nonsignificant trend of higher tactile acuity than those who did yoga for "physical exercise." There was no association between TPD threshold and cumulative amount of yoga practice in terms of hours per week and years of experience. However, increased hours of exercise per week correlated with higher TPD. The findings suggest that there may be a relationship between yoga practice and enhanced tactile acuity in the low back.

  18. Inert gas narcosis has no influence on thermo-tactile sensation.

    PubMed

    Jakovljević, Miroljub; Vidmar, Gaj; Mekjavic, Igor B

    2012-05-01

    Contribution of skin thermal sensors under inert gas narcosis to the raising hypothermia is not known. Such information is vital for understanding the impact of narcosis on behavioural thermoregulation, diver safety and judgment of thermal (dis)comfort in the hyperbaric environment. So this study aimed at establishing the effects of normoxic concentration of 30% nitrous oxide (N(2)O) on thermo-tactile threshold sensation by studying 16 subjects [eight females and eight males; eight sensitive (S) and eight non-sensitive (NS) to N(2)O]. Their mean (SD) age was 22.1 (1.8) years, weight 72.8 (15.3) kg, height 1.75 (0.10) m and body mass index 23.8 (3.8) kg m(-2). Quantitative thermo-tactile sensory testing was performed on forearm, upper arm and thigh under two experimental conditions: breathing air (air trial) and breathing normoxic mixture of 30% N(2)O (N(2)O trial) in the mixed sequence. Difference in thermo-tactile sensitivity thresholds between two groups of subjects in two experimental conditions was analysed by 3-way mixed-model analysis of covariance. There were no statistically significant differences in thermo-tactile thresholds either between the Air and N(2)O trials, or between S and NS groups, or between females and males, or with respect to body mass index. Some clinically insignificant lowering of thermo-tactile thresholds occurred only for warm thermo-tactile thresholds on upper arm and thigh. The results indicated that normoxic mixture of 30% N(2)O had no influence on thermo-tactile sensation in normothermia.

  19. Development of tactile sensory circuits in the CNS.

    PubMed

    Iwasato, Takuji; Erzurumlu, Reha S

    2018-06-13

    Molecular identification of neuronal types and genetic and imaging approaches to characterize their properties reveal morphological, physiological and dynamic aspects of sensory circuit development. Here we focus on the mouse tactile sensory circuitry, with particular emphasis on the main trigeminal pathway that connects the whiskers, the major tactile organ in rodents, to the neocortex. At each level of this pathway, neurogenesis, axonal elongation, pathfinding, target recognition and circuit reorganization including dendritic refinement of cortical layer 4 neurons occur contemporaneously and a multitude of molecular signals are used in differing combinations. We highlight recent advances in development of tactile circuitry and note gaps in our understanding. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Reward-prospect interacts with trial-by-trial preparation for potential distraction

    PubMed Central

    Marini, Francesco; van den Berg, Berry; Woldorff, Marty G.

    2015-01-01

    When attending for impending visual stimuli, cognitive systems prepare to identify relevant information while ignoring irrelevant, potentially distracting input. Recent work (Marini et al., 2013) showed that a supramodal distracter-filtering mechanism is invoked in blocked designs involving expectation of possible distracter stimuli, although this entails a cost (distraction-filtering cost) on speeded performance when distracters are expected but not presented. Here we used an arrow-flanker task to study whether an analogous cost, potentially reflecting the recruitment of a specific distraction-filtering mechanism, occurs dynamically when potential distraction is cued trial-to-trial (cued distracter-expectation cost). In order to promote the maximal utilization of cue information by participants, in some experimental conditions the cue also signaled the possibility of earning a monetary reward for fast and accurate performance. This design also allowed us to investigate the interplay between anticipation for distracters and anticipation of reward, which is known to engender attentional preparation. Only in reward contexts did participants show a cued distracter-expectation cost, which was larger with higher reward prospect and when anticipation for both distracters and reward were manipulated trial-to-trial. Thus, these results indicate that reward prospect interacts with the distracter expectation during trial-by-trial preparatory processes for potential distraction. These findings highlight how reward guides cue-driven attentional preparation. PMID:26180506

  1. Reward-prospect interacts with trial-by-trial preparation for potential distraction.

    PubMed

    Marini, Francesco; van den Berg, Berry; Woldorff, Marty G

    2015-02-01

    When attending for impending visual stimuli, cognitive systems prepare to identify relevant information while ignoring irrelevant, potentially distracting input. Recent work (Marini et al., 2013) showed that a supramodal distracter-filtering mechanism is invoked in blocked designs involving expectation of possible distracter stimuli, although this entails a cost ( distraction-filtering cost ) on speeded performance when distracters are expected but not presented. Here we used an arrow-flanker task to study whether an analogous cost, potentially reflecting the recruitment of a specific distraction-filtering mechanism, occurs dynamically when potential distraction is cued trial-to-trial ( cued distracter-expectation cost ). In order to promote the maximal utilization of cue information by participants, in some experimental conditions the cue also signaled the possibility of earning a monetary reward for fast and accurate performance. This design also allowed us to investigate the interplay between anticipation for distracters and anticipation of reward, which is known to engender attentional preparation. Only in reward contexts did participants show a cued distracter-expectation cost, which was larger with higher reward prospect and when anticipation for both distracters and reward were manipulated trial-to-trial. Thus, these results indicate that reward prospect interacts with the distracter expectation during trial-by-trial preparatory processes for potential distraction. These findings highlight how reward guides cue-driven attentional preparation.

  2. Reflections of Distraction in Memory: Transfer of Previous Distraction Improves Recall in Younger and Older Adults

    ERIC Educational Resources Information Center

    Thomas, Ruthann C.; Hasher, Lynn

    2012-01-01

    Three studies explored whether younger and older adults' free recall performance can benefit from prior exposure to distraction that becomes relevant in a memory task. Participants initially read stories that included distracting text. Later, they studied a list of words for free recall, with half of the list consisting of previously distracting…

  3. Driver Distraction Using Visual-Based Sensors and Algorithms.

    PubMed

    Fernández, Alberto; Usamentiaga, Rubén; Carús, Juan Luis; Casado, Rubén

    2016-10-28

    Driver distraction, defined as the diversion of attention away from activities critical for safe driving toward a competing activity, is increasingly recognized as a significant source of injuries and fatalities on the roadway. Additionally, the trend towards increasing the use of in-vehicle information systems is critical because they induce visual, biomechanical and cognitive distraction and may affect driving performance in qualitatively different ways. Non-intrusive methods are strongly preferred for monitoring distraction, and vision-based systems have appeared to be attractive for both drivers and researchers. Biomechanical, visual and cognitive distractions are the most commonly detected types in video-based algorithms. Many distraction detection systems only use a single visual cue and therefore, they may be easily disturbed when occlusion or illumination changes appear. Moreover, the combination of these visual cues is a key and challenging aspect in the development of robust distraction detection systems. These visual cues can be extracted mainly by using face monitoring systems but they should be completed with more visual cues (e.g., hands or body information) or even, distraction detection from specific actions (e.g., phone usage). Additionally, these algorithms should be included in an embedded device or system inside a car. This is not a trivial task and several requirements must be taken into account: reliability, real-time performance, low cost, small size, low power consumption, flexibility and short time-to-market. The key points for the development and implementation of sensors to carry out the detection of distraction will also be reviewed. This paper shows a review of the role of computer vision technology applied to the development of monitoring systems to detect distraction. Some key points considered as both future work and challenges ahead yet to be solved will also be addressed.

  4. Driver Distraction Using Visual-Based Sensors and Algorithms

    PubMed Central

    Fernández, Alberto; Usamentiaga, Rubén; Carús, Juan Luis; Casado, Rubén

    2016-01-01

    Driver distraction, defined as the diversion of attention away from activities critical for safe driving toward a competing activity, is increasingly recognized as a significant source of injuries and fatalities on the roadway. Additionally, the trend towards increasing the use of in-vehicle information systems is critical because they induce visual, biomechanical and cognitive distraction and may affect driving performance in qualitatively different ways. Non-intrusive methods are strongly preferred for monitoring distraction, and vision-based systems have appeared to be attractive for both drivers and researchers. Biomechanical, visual and cognitive distractions are the most commonly detected types in video-based algorithms. Many distraction detection systems only use a single visual cue and therefore, they may be easily disturbed when occlusion or illumination changes appear. Moreover, the combination of these visual cues is a key and challenging aspect in the development of robust distraction detection systems. These visual cues can be extracted mainly by using face monitoring systems but they should be completed with more visual cues (e.g., hands or body information) or even, distraction detection from specific actions (e.g., phone usage). Additionally, these algorithms should be included in an embedded device or system inside a car. This is not a trivial task and several requirements must be taken into account: reliability, real-time performance, low cost, small size, low power consumption, flexibility and short time-to-market. The key points for the development and implementation of sensors to carry out the detection of distraction will also be reviewed. This paper shows a review of the role of computer vision technology applied to the development of monitoring systems to detect distraction. Some key points considered as both future work and challenges ahead yet to be solved will also be addressed. PMID:27801822

  5. Internal maxillary distraction with a new bimalar device.

    PubMed

    Kahn, David M; Broujerdi, Joseph; Schendel, Stephen A

    2008-04-01

    Distraction osteogenesis of the Le Fort I segment is advocated for patients who require significant advancement of the maxilla or who have a soft tissue envelope compromised by scar tissue. We present a technique for maxillary distraction using an interconnecting intraoral device anchored to the malar prominences above the osteotomy and either the maxilla and/or the dentition below the level of the osteotomy. Ten patients with nonsyndromic cleft lip and palate, mean age of 18, underwent Le Fort I maxillary distraction osteogenesis for management of maxillary hypoplasia. A Le Fort I osteotomy is performed and a Spectrum Intraoral Midface Multi-Vector Distractor (OsteoMed, Addison, TX) is placed leaving a 1 mm to 2 mm distraction gap. After a 2 to 4 day latency period, distraction begins at a rate of 1 mm a day. Once the desired occlusion is achieved the device is left in place for a minimum of 2 months for consolidation. Preoperative Sella-Nasion-A point measurements from lateral cephalograms averaged 74 degrees (range, 70-76 degrees). Postoperative Sella-Nasion-A point averaged 81 degrees (range, 75-89 degrees). Preoperative overjet averaged -7.4 mm (range, -3 to -13 mm). Postoperative overjet averaged 2.6 mm (range, 1-3 mm). Average distraction was 9 mm (range, 6-16 mm). The average vertical movement was 7.2 mm in an inferior direction (range, 0-15 mm). The results remained stable at a follow-up of 30 months. We report on distraction of the Le Fort I segment using an internal device. The device design allows the forces of distraction to be shared across a larger surface area delivering a uniform and reliable vector of distraction with increased stability.

  6. Reach Trajectories Characterize Tactile Localization for Sensorimotor Decision Making.

    PubMed

    Brandes, Janina; Heed, Tobias

    2015-10-07

    Spatial target information for movement planning appears to be coded in a gaze-centered reference frame. In touch, however, location is initially coded with reference to the skin. Therefore, the tactile spatial location must be derived by integrating skin location and posture. It has been suggested that this recoding is impaired when the limb is placed in the opposite hemispace, for example, by limb crossing. Here, human participants reached toward visual and tactile targets located at uncrossed and crossed feet in a sensorimotor decision task. We characterized stimulus recoding by analyzing the timing and spatial profile of hand reaches. For tactile targets at crossed feet, skin-based information implicates the incorrect side, and only recoded information points to the correct location. Participants initiated straight reaches and redirected the hand toward a target presented in midflight. Trajectories to visual targets were unaffected by foot crossing. In contrast, trajectories to tactile targets were redirected later with crossed than uncrossed feet. Reaches to crossed feet usually continued straight until they were directed toward the correct tactile target and were not biased toward the skin-based target location. Occasional, far deflections toward the incorrect target were most likely when this target was implicated by trial history. These results are inconsistent with the suggestion that spatial transformations in touch are impaired by limb crossing, but are consistent with tactile location being recoded rapidly and efficiently, followed by integration of skin-based and external information to specify the reach target. This process may be implemented in a bounded integrator framework. How do you touch yourself, for instance, to scratch an itch? The place you need to reach is defined by a sensation on the skin, but our bodies are flexible, so this skin location could be anywhere in 3D space. The movement toward the tactile sensation must therefore be specified

  7. Identifying cognitive distraction using steering wheel reversal rates.

    PubMed

    Kountouriotis, Georgios K; Spyridakos, Panagiotis; Carsten, Oliver M J; Merat, Natasha

    2016-11-01

    The influence of driver distraction on driving performance is not yet well understood, but it can have detrimental effects on road safety. In this study, we examined the effects of visual and non-visual distractions during driving, using a high-fidelity driving simulator. The visual task was presented either at an offset angle on an in-vehicle screen, or on the back of a moving lead vehicle. Similar to results from previous studies in this area, non-visual (cognitive) distraction resulted in improved lane keeping performance and increased gaze concentration towards the centre of the road, compared to baseline driving, and further examination of the steering control metrics indicated an increase in steering wheel reversal rates, steering wheel acceleration, and steering entropy. We show, for the first time, that when the visual task is presented centrally, drivers' lane deviation reduces (similar to non-visual distraction), whilst measures of steering control, overall, indicated more steering activity, compared to baseline. When using a visual task that required the diversion of gaze to an in-vehicle display, but without a manual element, lane keeping performance was similar to baseline driving. Steering wheel reversal rates were found to adequately tease apart the effects of non-visual distraction (increase of 0.5° reversals) and visual distraction with offset gaze direction (increase of 2.5° reversals). These findings are discussed in terms of steering control during different types of in-vehicle distraction, and the possible role of manual interference by distracting secondary tasks. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Prototype tactile feedback system for examination by skin touch.

    PubMed

    Lee, O; Lee, K; Oh, C; Kim, K; Kim, M

    2014-08-01

    Diagnosis of conditions such as psoriasis and atopic dermatitis, in the case of induration, involves palpating the infected area via hands and then selecting a ratings score. However, the score is determined based on the tester's experience and standards, making it subjective. To provide tactile feedback on the skin, we developed a prototype tactile feedback system to simulate skin wrinkles with PHANToM OMNI. To provide the user with tactile feedback on skin wrinkles, a visual and haptic Augmented Reality system was developed. First, a pair of stereo skin images obtained by a stereo camera generates a disparity map of skin wrinkles. Second, the generated disparity map is sent to an implemented tactile rendering algorithm that computes a reaction force according to the user's interaction with the skin image. We first obtained a stereo image of skin wrinkles from the in vivo stereo imaging system, which has a baseline of 50.8 μm, and obtained the disparity map with a graph cuts algorithm. The left image is displayed on the monitor to enable the user to recognize the location visually. The disparity map of the skin wrinkle image sends skin wrinkle information as a tactile response to the user through a haptic device. We successfully developed a tactile feedback system for virtual skin wrinkle simulation by means of a commercialized haptic device that provides the user with a single point of contact to feel the surface roughness of a virtual skin sample. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. A multimodal dataset for various forms of distracted driving

    PubMed Central

    Taamneh, Salah; Tsiamyrtzis, Panagiotis; Dcosta, Malcolm; Buddharaju, Pradeep; Khatri, Ashik; Manser, Michael; Ferris, Thomas; Wunderlich, Robert; Pavlidis, Ioannis

    2017-01-01

    We describe a multimodal dataset acquired in a controlled experiment on a driving simulator. The set includes data for n=68 volunteers that drove the same highway under four different conditions: No distraction, cognitive distraction, emotional distraction, and sensorimotor distraction. The experiment closed with a special driving session, where all subjects experienced a startle stimulus in the form of unintended acceleration—half of them under a mixed distraction, and the other half in the absence of a distraction. During the experimental drives key response variables and several explanatory variables were continuously recorded. The response variables included speed, acceleration, brake force, steering, and lane position signals, while the explanatory variables included perinasal electrodermal activity (EDA), palm EDA, heart rate, breathing rate, and facial expression signals; biographical and psychometric covariates as well as eye tracking data were also obtained. This dataset enables research into driving behaviors under neatly abstracted distracting stressors, which account for many car crashes. The set can also be used in physiological channel benchmarking and multispectral face recognition. PMID:28809848

  10. Distractions in the School Science Laboratory

    ERIC Educational Resources Information Center

    Hamza, Karim M.

    2013-01-01

    In this article, I make a case for the potential educative worth of distractions for learning science in the school laboratory. Distractions are operationalized as experiences lying outside the main purpose of the laboratory activity, thereby diverting students' attention from that purpose. Through a practical epistemology analysis, I…

  11. Nitrogen narcosis and tactile shape memory in low visibility.

    PubMed

    van Wijk, Charles H; Meintjes, W A J

    2014-01-01

    Commercial diving often occurs in low visibility, where divers are reliant on their tactile senses. This study examined the effect of nitrogen narcosis on tactile memory for shapes as well as the influence of psychological and biographical factors on this relationship. This crossover study tested 139 commercial divers in a dry hyperbaric chamber at 101.325 and 607.95 kPa (1 and 6 atmospheres absolute/atm abs). Divers memorized shapes while blindfolded, using their tactile senses only. Delayed recall was measured at the surface after each dive. Psychological and biographical data were also collected. A significant effect of hyperbaric pressure on tactile memory was demonstrated, and a further effect of sequence of testing found. Thus, divers' delayed shape recall deteriorated by 8% after learning material at depth, compared to learning on the surface. There were also significant but small effects of psychological and biographical markers on tactile memory performance, with lower trait anxiety associated with better recall, and lower education associated with poorer recall. The findings emphasize the importance of utilizing other forms of recording of events or objects at depth, particularly in conditions of low visibility during deeper diving, to aid memory encoding and subsequent recall at the surface.

  12. Temporary Segmental Distraction in a Dog with Degenerative Lumbosacral Stenosis.

    PubMed

    Willems, Nicole; Kersten, Roel F M R; van Gaalen, Steven M; Öner, F Cumhur; Strijkers, Gustav J; Veraa, Stefanie; Beukers, Martijn; Tryfonidou, Marianna A; Meij, Björn P

    2018-06-02

     Degenerative lumbosacral stenosis (DLSS) is characterized by intervertebral disc degeneration and causes lower back pain in dogs. Temporary distraction in rabbit models with induced intervertebral disc degeneration showed signs of intervertebral disc repair. In the present study, we assessed safety and efficacy of temporary segmental distraction in a dog with clinical signs of DLSS.  Distraction of the lumbosacral junction by pedicle screw-rod fixation was applied in a 5-year-old Greyhound with DLSS and evaluated by radiography, magnetic resonance imaging, and force plate analysis before and after distraction.  Safe distraction of the lumbosacral junction was demonstrated, with improvement of clinical signs after removal of the distraction device. Signal intensity of the intervertebral disc showed no changes over time. T2 value was highest directly after removal of the distraction device but decreased by 10% of the preoperative value at 9 months of follow-up. Disc height decreased (8%) immediately after removal of the distraction device, but recovered to the initial value. A decrease in the pelvic/thoracic propulsive force during pedicle screw-rod fixation and distraction was demonstrated, which slowly increased by 4% compared with the initial value.  Temporary pedicle screw-rod fixation in combination with distraction in a dog with DLSS was safe, improved clinical signs and retained disc height at 9 months of follow-up. Schattauer GmbH Stuttgart.

  13. A minipig model of maxillary distraction osteogenesis.

    PubMed

    Papadaki, Maria E; Troulis, Maria J; Glowacki, Julie; Kaban, Leonard B

    2010-11-01

    To establish a porcine model for maxillary distraction osteogenesis and to document the sequence of bone formation in the zone of advancement. Female Yucatan minipigs (n = 9) in the mixed dentition stage underwent modified Le Fort I osteotomy through a vestibular incision under general anesthesia. A unidirectional, semiburied Le Fort I distraction device was fixed across the osteotomy. The distraction protocol was 0-day latency, 1-mm/d rate for 12 days, and 24 days of fixation. Maxillary specimens (n = 9) were harvested and divided in half at the end of distraction (n = 6 sides), midfixation (n = 6), and the end of fixation (n = 6). Clinical stability, volume, and radiographic density across the zone of advancement were graded on semiquantitative scales. Specimens were stained with hematoxylin and eosin and examined with light microscopy. Animals tolerated the operation, the distraction and fixation periods. There were no infections and no devices failed. At the end of the distraction period, bone trabeculae were present at the periphery and fibrous tissues, and vessels, preosteoblasts, and osteoblasts were present in the center of the zone of advancement. Islands of chondrocyte-like cells appeared in 1 specimen each at midfixation and the end of fixation. At the end of fixation, clinical stability and radiographic density were graded 3/3 and bone formation was complete across the advancement zone in all specimens. A model for Le Fort I distraction osteogenesis was established. Intramembranous bone formation was the predominant mechanism of healing in the zone of advancement. Latency was not necessary for bone formation in this minipig model. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Meet our Neighbours - a tactile experience

    NASA Astrophysics Data System (ADS)

    Canas, L.; Lobo Correia, A.

    2013-09-01

    Planetary science is a key field in astronomy that draws lots of attention and that engages large amounts of enthusiasts. On its essence, it is a visual science and the current resources and activities for the inclusion of visually impaired children, although increasing, are still costly and somewhat scarce. Therefore there is a paramount need to develop more low cost resources in order to provide experiences that can reach all, even the more socially deprived communities. "Meet our neighbours!-a tactile experience", plans to promote and provide inclusion activities for visually impaired children and their non-visually impaired peers through the use of astronomy hands-on low cost activities. Is aimed for children from the ages of 6 to 12 years old and produce data set 13 tactile images of the main objects of the Solar System that can be used in schools, science centres and outreach associations. Accessing several common problems through tactile resources, with this project we present ways to successfully provide low cost solutions (avoiding the expensive tactile printing costs), promote inclusion and interactive hands-on activities for visually impaired children and their non-visually impaired peers and create dynamic interactions based on oral knowledge transmission between them. Here we describe the process of implementing such initiative near target communities: establishing a bridge between scientists, children and teachers. The struggles and challenges perceived during the project and the enrichment experience of engaging astronomy with these specific groups, broadening horizons in an overall experience accessible to all.

  15. Evolutionary Specialization of Tactile Perception in Vertebrates.

    PubMed

    Schneider, Eve R; Gracheva, Elena O; Bagriantsev, Slav N

    2016-05-01

    Evolution has endowed vertebrates with the remarkable tactile ability to explore the world through the perception of physical force. Yet the sense of touch remains one of the least well understood senses at the cellular and molecular level. Vertebrates specializing in tactile perception can highlight general principles of mechanotransduction. Here, we review cellular and molecular adaptations that underlie the sense of touch in typical and acutely mechanosensitive vertebrates. ©2016 Int. Union Physiol. Sci./Am. Physiol. Soc.

  16. Braille in the Sighted: Teaching Tactile Reading to Sighted Adults.

    PubMed

    Bola, Łukasz; Siuda-Krzywicka, Katarzyna; Paplińska, Małgorzata; Sumera, Ewa; Hańczur, Paweł; Szwed, Marcin

    2016-01-01

    Blind people are known to have superior perceptual abilities in their remaining senses. Several studies suggest that these enhancements are dependent on the specific experience of blind individuals, who use those remaining senses more than sighted subjects. In line with this view, sighted subjects, when trained, are able to significantly progress in relatively simple tactile tasks. However, the case of complex tactile tasks is less obvious, as some studies suggest that visual deprivation itself could confer large advantages in learning them. It remains unclear to what extent those complex skills, such as braille reading, can be learnt by sighted subjects. Here we enrolled twenty-nine sighted adults, mostly braille teachers and educators, in a 9-month braille reading course. At the beginning of the course, all subjects were naive in tactile braille reading. After the course, almost all were able to read whole braille words at a mean speed of 6 words-per-minute. Subjects with low tactile acuity did not differ significantly in braille reading speed from the rest of the group, indicating that low tactile acuity is not a limiting factor for learning braille, at least at this early stage of learning. Our study shows that most sighted adults can learn whole-word braille reading, given the right method and a considerable amount of motivation. The adult sensorimotor system can thus adapt, to some level, to very complex tactile tasks without visual deprivation. The pace of learning in our group was comparable to congenitally and early blind children learning braille in primary school, which suggests that the blind's mastery of complex tactile tasks can, to a large extent, be explained by experience-dependent mechanisms.

  17. Braille in the Sighted: Teaching Tactile Reading to Sighted Adults

    PubMed Central

    Bola, Łukasz; Siuda-Krzywicka, Katarzyna; Paplińska, Małgorzata; Sumera, Ewa; Hańczur, Paweł; Szwed, Marcin

    2016-01-01

    Blind people are known to have superior perceptual abilities in their remaining senses. Several studies suggest that these enhancements are dependent on the specific experience of blind individuals, who use those remaining senses more than sighted subjects. In line with this view, sighted subjects, when trained, are able to significantly progress in relatively simple tactile tasks. However, the case of complex tactile tasks is less obvious, as some studies suggest that visual deprivation itself could confer large advantages in learning them. It remains unclear to what extent those complex skills, such as braille reading, can be learnt by sighted subjects. Here we enrolled twenty-nine sighted adults, mostly braille teachers and educators, in a 9-month braille reading course. At the beginning of the course, all subjects were naive in tactile braille reading. After the course, almost all were able to read whole braille words at a mean speed of 6 words-per-minute. Subjects with low tactile acuity did not differ significantly in braille reading speed from the rest of the group, indicating that low tactile acuity is not a limiting factor for learning braille, at least at this early stage of learning. Our study shows that most sighted adults can learn whole-word braille reading, given the right method and a considerable amount of motivation. The adult sensorimotor system can thus adapt, to some level, to very complex tactile tasks without visual deprivation. The pace of learning in our group was comparable to congenitally and early blind children learning braille in primary school, which suggests that the blind’s mastery of complex tactile tasks can, to a large extent, be explained by experience-dependent mechanisms. PMID:27187496

  18. Effect of maxillary distraction osteogenesis on velopharyngeal function: a pilot study.

    PubMed

    Harada, Kiyoshi; Ishii, Yoshimasa; Ishii, Masatoshi; Imaizumi, Humiko; Mibu, Michiko; Omura, Ken

    2002-05-01

    The purpose of this study was to examine preoperative and postoperative changes of velopharyngeal function in cleft patients who underwent maxillary distraction osteogenesis using the Rigid External Distraction System. Six cleft patients followed for a minimum of 12 months after maxillary distraction were examined. Plain and contrast lateral-cephalograms were obtained preoperatively and postoperatively, and speech evaluation was performed by the same authorized speech therapist at the same time points. The mean distraction amount at the anterior nasal spine was 11.7 mm (range, 7.4 mm - 15.0 mm). Both the nasopharyngeal depth and velar length increased after maxillary distraction, but the need ratio (nasopharyngeal depth/velar length) also increased after distraction. Although scores for velopharyngeal closure dropped a few points after maxillary distraction, the rating for hypernasality remained unchanged in all patients but the patient whose distraction amount was 15.0 mm. These results suggest that maxillary distraction of less than 15 mm may not markedly affect velopharyngeal function in cleft patients.

  19. Merkel disc is a serotonergic synapse in the epidermis for transmitting tactile signals in mammals.

    PubMed

    Chang, Weipang; Kanda, Hirosato; Ikeda, Ryo; Ling, Jennifer; DeBerry, Jennifer J; Gu, Jianguo G

    2016-09-13

    The evolution of sensory systems has let mammals develop complicated tactile end organs to enable sophisticated sensory tasks, including social interaction, environmental exploration, and tactile discrimination. The Merkel disc, a main type of tactile end organ consisting of Merkel cells (MCs) and Aβ-afferent endings, are highly abundant in fingertips, touch domes, and whisker hair follicles of mammals. The Merkel disc has high tactile acuity for an object's physical features, such as texture, shape, and edges. Mechanisms underlying the tactile function of Merkel discs are obscured as to how MCs transmit tactile signals to Aβ-afferent endings leading to tactile sensations. Using mouse whisker hair follicles, we show herein that tactile stimuli are transduced by MCs into excitatory signals that trigger vesicular serotonin release from MCs. We identify that both ionotropic and metabotropic 5-hydroxytryptamine (5-HT) receptors are expressed on whisker Aβ-afferent endings and that their activation by serotonin released from MCs initiates Aβ-afferent impulses. Moreover, we demonstrate that these ionotropic and metabotropic 5-HT receptors have a synergistic effect that is critical to both electrophysiological and behavioral tactile responses. These findings elucidate that the Merkel disc is a unique serotonergic synapse located in the epidermis and plays a key role in tactile transmission. The epidermal serotonergic synapse may have important clinical implications in sensory dysfunctions, such as the loss of tactile sensitivity and tactile allodynia seen in patients who have diabetes, inflammatory diseases, and undergo chemotherapy. It may also have implications in the exaggerated tactile sensations induced by recreational drugs that act on serotoninergic synapses.

  20. Tactile display device using an electrorheological fluid

    NASA Technical Reports Server (NTRS)

    Garner, H. Douglas (Inventor)

    1994-01-01

    A tactile display device utilizes an electrorheological fluid to activate a plurality of tactile dots. A voltage is selectively produced uniformly across an electrorheological fluid flowing between a common ground electrode and a plurality of conductive dot electrodes, thereby producing an increase in the fluid's viscosity to the extent that fluid flow between the two electrodes is restricted. The flow restriction produces a build-up of electrorheological fluid in a corresponding dot actuator chamber. The resulting pressure increase in the chamber displaces an elastic diaphragm fixed to a display surface to form a lump which can be perceived by the reader as one dot in a Braille character cell. A flow regulation system provides a continually pressurized flow system and provides for free flow of the electrorheological fluid through the plurality of dot actuator chambers when they are not activated. The device is adaptable to printed circuit techniques and can simultaneously display tactile dots representative of a full page of Braille characters stored on a medium such as a tape cassette or to display tactile dots representative of non-Braille data appearing on a computer monitor or contained on another data storage medium. In an alternate embodiment, the elastic diaphragm drives a plurality of spring-loaded pins provided with positive stops to maintain consistent displacements of the pins in both their actuated and nonactuated positions.

  1. Where are my hands? Influence of limb posture on tactile extinction.

    PubMed

    Auclair, Laurent; Barra, Julien; Raibaut, Patrick

    2012-05-01

    Tactile localization on the skin involves both a somatotopic and a postural schema (body-schema) representation. The present study determines the extent to which body posture influences tactile perception in right-brain-damaged patients. In a first set of experiments, patients were asked to detect single tactile stimulation delivered to their left or right hands or to both hands simultaneously (double stimulation) in different arm postures. Only patients who had no difficulty localizing single and double tactile stimulations when their hands were placed in anatomic position were tested. Participant's hands were crossed, one over the other, and the tactile stimuli were delivered either to the hand (beyond the crossing point, Experiment 1) or to the forearm (before the crossing point, Experiment 2). In Experiment 3, the left hand was placed in the right hemispace and the right hand in the left hemispace without crossing over (opposite condition). In a second set of experiments, patients were asked to detect stimulation delivered to the forefinger. The fingers were crossed, one over the other at the level of the middle phalanx, and stimuli were delivered either beyond or before the crossing point. In all experimental conditions, control participants performed at ceiling. We observed a left-hand tactile extinction on double stimulation in the crossed condition. These results suggest that tactile stimuli can be encoded based on multiple specific body-part representations rather than on an integrated body-schema representation.

  2. Tactile Acuity Charts: A Reliable Measure of Spatial Acuity

    PubMed Central

    Bruns, Patrick; Camargo, Carlos J.; Campanella, Humberto; Esteve, Jaume; Dinse, Hubert R.; Röder, Brigitte

    2014-01-01

    For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds. PMID:24504346

  3. 77 FR 61048 - Distracted Driving Grant Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-05

    ... DEPARTMENT OF TRANSPORTATION National Highway Traffic Safety Administration Distracted Driving Grant Program AGENCY: National Highway Traffic Safety Administration (NHTSA), Department of... distracted driving grants on August 24, 2012. In this notice, DOT is extending the application submission...

  4. Mindless Feeding: Is Maternal Distraction During Bottle-Feeding Associated with Overfeeding?

    PubMed Central

    Golen, Rebecca B.; Ventura, Alison K.

    2015-01-01

    Mindless eating, or eating while distracted by surrounding stimuli, leads to overeating. The present study explored whether “mindless feeding,” or maternal distraction during bottle-feeding, is associated with greater infant formula/milk intakes and lower maternal sensitivity to infant cues. Mothers and their ≤24-week-old bottle-feeding infants (N=28) visited our laboratory for a video-recorded feeding observation. Infant intake was assessed by weighing bottles before and after the feedings. Maternal sensitivity to infant cues was objectively assessed by behavioral coding of video-records using the Nursing Child Assessment Feeding Scale. Maternal distraction was defined as looking away from the infant >75% of the feeding; using a mobile device; conversing with another adult; or sleeping. Twenty-nine percent (n=8) of mothers were distracted. While differences in intakes for infants of distracted vs. not distracted mothers did not reach significance (p=0.24), the association between distraction and infant intake was modified by two dimensions of temperament: orienting/regulation capacity (p=0.03) and surgency/extraversion (p=0.04). For infants with low orienting/regulation capacity, infants of distracted mothers consumed more (177.1 ± 33.8 ml) than those of not distracted mothers (92.4 ± 13.8 ml). Similar findings were noted for infants with low surgency/extraversion (distracted: 140.6 ± 22.5 ml; not distracted: 78.4 ± 14.3 ml). No association between distraction and intake was seen for infants with high orienting/regulation capacity or surgency/extraversion. A significantly greater proportion of distracted mothers showed low sensitivity to infant cues compared to not distracted mothers (p=0.04). In sum, mindless feeding may interact with infant characteristics to influence feeding outcomes; further experimental and longitudinal studies are needed. PMID:25953601

  5. Force/torque and tactile sensors for sensor-based manipulator control

    NASA Technical Reports Server (NTRS)

    Vanbrussel, H.; Belieen, H.; Bao, Chao-Ying

    1989-01-01

    The autonomy of manipulators, in space and in industrial environments, can be dramatically enhanced by the use of force/torque and tactile sensors. The development and future use of a six-component force/torque sensor for the Hermes Robot Arm (HERA) Basic End-Effector (BEE) is discussed. Then a multifunctional gripper system based on tactile sensors is described. The basic transducing element of the sensor is a sheet of pressure-sensitive polymer. Tactile image processing algorithms for slip detection, object position estimation, and object recognition are described.

  6. Resonant vibrating sensors for tactile tissue differentiation

    NASA Astrophysics Data System (ADS)

    Hemsel, T.; Stroop, R.; Oliva Uribe, D.; Wallaschek, J.

    2007-12-01

    Surgical resection of brain tumours is a difficult task. To enhance surgery results, a tactile sensor is wanted that gives better resolution and sensitivity than the human tactile sense. The characteristics of resonant vibrating piezoelectric elements change with varying load. This allows for calculation of mechanical load parameters by measuring electrical quantities. Different setups of piezoelectric sensors have been used to investigate soft materials. Finally, a piezoelectric bimorph sensor gave good results for distinguishing tissue mimicking gel-phantoms with different gelatine concentrations.

  7. Scalable fabric tactile sensor arrays for soft bodies

    NASA Astrophysics Data System (ADS)

    Day, Nathan; Penaloza, Jimmy; Santos, Veronica J.; Killpack, Marc D.

    2018-06-01

    Soft robots have the potential to transform the way robots interact with their environment. This is due to their low inertia and inherent ability to more safely interact with the world without damaging themselves or the people around them. However, existing sensing for soft robots has at least partially limited their ability to control interactions with their environment. Tactile sensors could enable soft robots to sense interaction, but most tactile sensors are made from rigid substrates and are not well suited to applications for soft robots which can deform. In addition, the benefit of being able to cheaply manufacture soft robots may be lost if the tactile sensors that cover them are expensive and their resolution does not scale well for manufacturability. This paper discusses the development of a method to make affordable, high-resolution, tactile sensor arrays (manufactured in rows and columns) that can be used for sensorizing soft robots and other soft bodies. However, the construction results in a sensor array that exhibits significant amounts of cross-talk when two taxels in the same row are compressed. Using the same fabric-based tactile sensor array construction design, two different methods for cross-talk compensation are presented. The first uses a mathematical model to calculate a change in resistance of each taxel directly. The second method introduces additional simple circuit components that enable us to isolate each taxel electrically and relate voltage to force directly. Fabric sensor arrays are demonstrated for two different soft-bodied applications: an inflatable single link robot and a human wrist.

  8. Happiness increases distraction by auditory deviant stimuli.

    PubMed

    Pacheco-Unguetti, Antonia Pilar; Parmentier, Fabrice B R

    2016-08-01

    Rare and unexpected changes (deviants) in an otherwise repeated stream of task-irrelevant auditory distractors (standards) capture attention and impair behavioural performance in an ongoing visual task. Recent evidence indicates that this effect is increased by sadness in a task involving neutral stimuli. We tested the hypothesis that such effect may not be limited to negative emotions but reflect a general depletion of attentional resources by examining whether a positive emotion (happiness) would increase deviance distraction too. Prior to performing an auditory-visual oddball task, happiness or a neutral mood was induced in participants by means of the exposure to music and the recollection of an autobiographical event. Results from the oddball task showed significantly larger deviance distraction following the induction of happiness. Interestingly, the small amount of distraction typically observed on the standard trial following a deviant trial (post-deviance distraction) was not increased by happiness. We speculate that happiness might interfere with the disengagement of attention from the deviant sound back towards the target stimulus (through the depletion of cognitive resources and/or mind wandering) but help subsequent cognitive control to recover from distraction. © 2015 The British Psychological Society.

  9. 75 FR 45696 - Pipeline Safety: Personal Electronic Device Related Distractions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-03

    ... of PEDs. Such distractions may also hinder their prompt recognition and reaction to abnormal... distractions caused by the use of PEDs. Such distractions may also hinder their prompt recognition and reaction...

  10. Nano opto-mechanical systems (NOMS) as a proposal for tactile displays

    NASA Astrophysics Data System (ADS)

    Campo, E. M.; Roig, J.; Roeder, B.; Wenn, D.; Mamojka, B.; Omastova, M.; Terentjev, E. M.; Esteve, J.

    2011-10-01

    For over a decade, special emphasis has been placed in the convergence of different fields of science and technology, in an effort to serve human needs by way of enhancing human capabilities. The convergence of the Nano-Bio-Info-Cogni (NBIC) quartet will provide unique solutions to specific needs. This is the case of, Nano-opto mechanical Systems (NOMS), presented as a solution to tactile perception, both for the visually-impaired and for the general public. NOMS, based on photoactive polymer actuators and devices, is a much sought-after technology. In this scheme, light sources promote mechanical actuation producing a variety of nano-opto mechanical systems such as nano-grippers. In this paper, we will provide a series of specifications that the NOMS team is targeting towards the development of a tactile display using optically-activated smart materials. Indeed, tactile displays remain mainly mechanical, compromising reload speeds and resolution which inhibit 3D tactile representation of web interfaces. We will also discuss how advantageous NOMS tactile displays could be for the general public. Tactile processing based on stimulation delivered through the NOMS tablet, will be tested using neuropsychology methods, in particular event-related brain potentials. Additionally, the NOMS tablet will be instrumental to the development of basic neuroscience research.

  11. When loading working memory reduces distraction: behavioral and electrophysiological evidence from an auditory-visual distraction paradigm.

    PubMed

    SanMiguel, Iria; Corral, María-José; Escera, Carles

    2008-07-01

    The sensitivity of involuntary attention to top-down modulation was tested using an auditory-visual distraction task and a working memory (WM) load manipulation in subjects performing a simple visual classification task while ignoring contingent auditory stimulation. The sounds were repetitive standard tones (80%) and environmental novel sounds (20%). Distraction caused by the novel sounds was compared across a 1-back WM condition and a no-memory control condition, both involving the comparison of two digits. Event-related brain potentials (ERPs) to the sounds were recorded, and the N1/MMN (mismatch negativity), novelty-P3, and RON components were identified in the novel minus standard difference waveforms. Distraction was reduced in the WM condition, both behaviorally and as indexed by an attenuation of the late phase of the novelty-P3. The transient/change detection mechanism indexed by MMN was not affected by the WM manipulation. Sustained slow frontal and parietal waveforms related to WM processes were found on the standard ERPs. The present results indicate that distraction caused by irrelevant novel sounds is reduced when a WM component is involved in the task, and that this modulation by WM load takes place at a late state of the orienting response, all in all confirming that involuntary attention is under the control of top-down mechanisms. Moreover, as these results contradict predictions of the load theory of selective attention and cognitive control, it is suggested that the WM load effects on distraction depend on the nature of the distractor-target relationships.

  12. The role of motivation in distracting attention away from pain: an experimental study.

    PubMed

    Verhoeven, Katrien; Crombez, Geert; Eccleston, Christopher; Van Ryckeghem, Dimitri M L; Morley, Stephen; Van Damme, Stefaan

    2010-05-01

    Research on the effectiveness of distraction as a method of pain control is inconclusive. One mechanism pertains to the motivational relevance of distraction tasks. In this study the motivation to engage in a distraction task during pain was experimentally manipulated. Undergraduate students (N=73) participated in a cold pressor test (CPT) and were randomly assigned to three groups: a distraction-only group performed a tone-detection task during the CPT, a motivated-distraction group performed the same task and received a monetary reward for good task performance, and a control group did not perform the tone-detection task. Results indicated that engagement in the distraction task was better in the motivated-distraction group in comparison with the distraction-only group. Participants in both distraction groups experienced less pain compared to the control group. There were no overall differences in pain intensity between the two distraction groups. The effect of distraction was influenced by the level of catastrophic thinking about pain. For low catastrophizers, both distraction groups reported less pain as compared to the non-distracted control group. This was not the case for high catastrophizers. For high catastrophizers it mattered whether the distraction task was motivationally relevant: high catastrophizers reported less intense pain in the motivated-distraction group, as compared to the non-distracted control group. We conclude that increasing the motivational relevance of the distraction task may increase the effects of distraction, especially for those who catastrophize about pain. Copyright 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  13. Prevalence of and factors associated with distraction among public transit bus drivers

    PubMed Central

    Griffin, Russell; Huisingh, Carrie; McGwin, Gerald

    2015-01-01

    Objective Recent research has suggested that driver distraction is a major cause of driving performance impairment and motor vehicle collisions. Research on the topic has focused on passenger vehicles, with studies suggesting that drivers may be distracted nearly 33% of the time spent driving. To date, no study has examined the prevalence of distraction specifically among public transit bus drivers. Methods Over a three-month period, trained investigators observed and recorded distraction behaviors of bus drivers. Distraction prevalence was compared by route characteristics (e.g., geographic area, travel speed) using chi-square test. A general estimating equation logistic regression was used to estimate p-values for distraction prevalence by driver demographics. Results Overall, there was a 39% prevalence of distraction. The most prevalent distractions were due to interactions with another passenger. Distractions were more prevalent among drivers <30 years of age or ≥50 years of age, on city streets or highways (relative to residential streets), and when there were more than 20 passengers. Distractions were the least prevalent in suburban areas, with the highest prevalence observed in city centers and rural areas. Conclusions Driver distraction is a common problem for public transit bus drivers, mainly due to other passengers. Drivers should be educated on the hazards of distracted driving and on ways to avoid distraction. PMID:24433192

  14. Response of ramus following vertical lengthening with distraction osteogenesis.

    PubMed

    Tuzuner-Oncul, Aysegul Mine; Kisnisci, Reha S

    2011-09-01

    Vertical lengthening of the mandibular ramus is considered to be one of the least stable surgical procedures in the management of musculoskeletal maxillofacial deformities. The aim of this study was to evaluate the response of the mandibular ramus following vertical lengthening by means of distraction osteogenesis. This study included eight non-syndromic adult patients with temporomandibular joint ankylosis. The vertical height deficiency of the mandibular ramus and the ramus/condyle unit on the affected side were simultaneously reconstructed by transportation of a bone segment using distraction osteogenesis following gap arthroplasty. Lateral and posteroanterior (PA) cephalograms taken postoperatively before active distraction, at the completion of distraction and 6, 12, 24 months after distraction, were compared to evaluate the changes of the ramus height. In all cases the vertical ramus and ramus/condyle unit height loss were successfully reconstructed by distraction osteogenesis. There was no relapse in the amount of height gained by distraction osteogenesis at the 24 months follow-up review (p>0.05). Acute one stage vertical lengthening of the mandibular ramus is considered to be one of the least stable musculoskeletal procedures with relapse being a significant adverse outcome. In this clinical study gradual vertical lengthening of the ramus through ramus/condyle unit distraction osteogenesis has maintained the initial vertical ramus height gained for 24 months. Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. The prevalence of distraction among passenger vehicle drivers: a roadside observational approach.

    PubMed

    Huisingh, Carrie; Griffin, Russell; McGwin, Gerald

    2015-01-01

    Distracted driving contributes to a large proportion of motor vehicle crashes, yet little is known about the prevalence of distracted driving and the specific types of distracting behaviors. The objective of this study was to estimate the prevalence of driver distraction using a roadside observational study design. A cross-sectional survey involving direct roadside observation was conducted at 11 selected intersections. Trained investigators observed a sample of passenger vehicles and recorded distraction-related behaviors, driver characteristics, and contextual factors such as vehicle speed and traffic flow. Of the 3,265 drivers observed, the prevalence of distracted driving was 32.7%. Among those involved in a distracting activity, the most frequently observed distractions included interacting with another passenger (53.2%, where passengers were present), talking on the phone (31.4%), external-vehicle distractions (20.4%), and texting/dialing a phone (16.6%). The prevalence of talking on the phone was higher among females than males (38.6% vs. 24.3%), whereas external vehicle distractions were higher among males than females (25.8% vs. 24.3%). Drivers <30 years were observed being engaged in any distracting activity, interacting with other passengers, and texting/dialing more frequently than drivers aged 30-50 and >50 years. Drivers were engaged in distracting behaviors more frequently when the car was stopped. When using similar methodology, roadside observational studies generate comparable prevalence estimates of driver distraction as naturalistic driving studies. Driver distraction is a common problem among passenger vehicle drivers. Despite the increased awareness on the dangers of texting and cell phone use while driving, these specific activities were 2 of the most frequently observed distractions. There is a continued need for road safety education about the dangers of distracted driving, especially for younger drivers.

  16. Assessing Cognitive Distraction in the Automobile.

    PubMed

    Strayer, David L; Turrill, Jonna; Cooper, Joel M; Coleman, James R; Medeiros-Ward, Nathan; Biondi, Francesco

    2015-12-01

    The objective was to establish a systematic framework for measuring and understanding cognitive distraction in the automobile. Driver distraction from secondary in-vehicle activities is increasingly recognized as a significant source of injuries and fatalities on the roadway. Across three studies, participants completed eight in-vehicle tasks commonly performed by the driver of an automobile. Primary, secondary, subjective, and physiological measures were collected and integrated into a cognitive distraction scale. In-vehicle activities, such as listening to the radio or an audio book, were associated with a low level of cognitive workload; the conversation activities of talking to a passenger in the vehicle or conversing with a friend on a handheld or hands-free cell phone were associated with a moderate level of cognitive workload; and using a speech-to-text interfaced e-mail system involved a high level of cognitive workload. The research established that there are significant impairments to driving that stem from the diversion of attention from the task of operating a motor vehicle and that the impairments to driving are directly related to the cognitive workload of these in-vehicle activities. Moreover, the adoption of voice-based systems in the vehicle may have unintended consequences that adversely affect traffic safety. These findings can be used to help inform scientifically based policies on driver distraction, particularly as they relate to cognitive distraction stemming from the diversion of attention to other concurrent activities in the vehicle. © 2015, Human Factors and Ergonomics Society.

  17. Learning in Tactile Channels

    ERIC Educational Resources Information Center

    Gescheider, George A.; Wright, John H.

    2012-01-01

    Vibrotactile intensity-discrimination thresholds for sinusoidal stimuli applied to the thenar eminence of the hand declined as a function of practice. However, improvement was confined to the tactile information-processing channel in which learning had occurred. Specifically, improvements in performance with training within the Pacinian-corpuscle…

  18. Can tactile sensory processing differentiate between children with autistic disorder and asperger's disorder?

    PubMed

    Ghanizadeh, Ahmad

    2011-05-01

    There are debates whether autistic disorder (autism) and Asperger's disorder are two distinct disorders. Moreover, interventional sensory occupational therapy should consider the clinical characteristics of patients. Already, commonalities and differences between Asperger's disorder and autistic disorder are not well studied. The aim of this study is to compare tactile sensory function of children with autistic disorder and children with Asperger's disorder. Tactile sensory function was compared between 36 children with autism and 19 children with Asperger's disorder. The two disorders were diagnosed based on Diagnostic and Statistical Manual of Mental Disorders Fourth Edition, Text Revision. The parent-reported Tactile Dysfunction Checklist was used to assess the three aspects of hypersensitivity, hyposensitivity, and poor tactile perception and discrimination. Developmental coordination was also assessed. Developmental coordination problems total score was not associated with group. The mean (standard deviation) score of tactile hyper-responsivity was not different between the groups. Tactile hyporesponsivity and poor tactile perception and discrimination scores were statistically higher in autistic disorder than Asperger's disorder group. These results for the first time indicated that at least some aspects of tactile perception can differentiate these two disorders. Children with autistic disorder have more tactile sensory seeking behaviors than children with Asperger's disorder. Moreover, the ability of children with autistic disorder for tactile discrimination and sensory perception is less than those with Asperger's disorder. Interventional sensory therapy in children with autistic disorder should have some characteristics that can be different and specific for children with Asperger's disorder. Formal intelligence quotient testing was not performed on all of the children evaluated, which is a limitation to this study. In some cases, a clinical estimation of

  19. A reconfigurable tactile display based on polymer MEMS technology

    NASA Astrophysics Data System (ADS)

    Wu, Xiaosong

    A tactile display provides information such as shape, texture, temperature, and hardness to a user. Ultimately, a tactile display could be used to recreate a virtual object that may be stored in a computer. However, such advanced displays are not yet widely available, primarily due to the lack of low cost, large area, compact actuator arrays that can stimulate the large numbers of receptors of the user and that can also meet the high requirements for user safety and comfort. This research focuses on the development of polymer microfabrication technologies for the realization of two major components of a pneumatic tactile display: a microactuator array and a complementary microvalve (control) array. In this work, the concept, fabrication, and characterization of a kinematically-stabilized polymeric microbubble actuator ("endoskeletal microbubble actuator") is presented. A systematic design and modeling procedure was carried out to generate an optimized geometry of the corrugated diaphragm to satisfy membrane deflection, force, and stability requirements set forth by the tactile display goals. A mass-manufacturable actuator has been fabricated using the approaches of lithography and micromolding. A prototype of a single endoskeletal bubble actuator with a diameter of 2.6mm has been fabricated and characterized. In addition, in order to further reduce the size and cost of the tactile display, a microvalve array can be integrated into the tactile display system to control the pneumatic fluid that actuates the microbubble actuator. A piezoelectrically-driven and hydraulically-amplified polymer microvalve has been designed, fabricated, and tested. An incompressible elastomer was used as a solid hydraulic medium to convert the small axial displacement of a piezoelectric actuator into a large valve head stroke while maintaining a large blocking force. The function of the microvalve as an on-off switch for a pneumatic microbubble tactile actuator has been demonstrated

  20. A Source of Distractions in the Classroom: The Teacher.

    ERIC Educational Resources Information Center

    Wong, Lily Y. S.

    This paper identifies distracting factors which take away pupils' attention from the lesson and focus it on the teacher. Distracting factors include teachers' irritating habits, improper attire, and mannerisms. Examples of distracting features of both males and females are listed in eight categories: (1) attire; (2) hair; (3) make-up; (4) personal…

  1. Percutaneous distraction lengthening in brachymetacarpia.

    PubMed

    Volpi, Alexander D; Fragomen, Austin T

    2011-08-08

    Brachymetacarpia is a condition manifesting a shortened metacarpal that is caused by early closure of the epiphyseal plate and believed to arise idiopathically. The correction for brachymetacarpia is usually for cosmetic reasons as brachymetacarpia does not impair function. The literature indicates several different approaches to lengthening digits, including single-stage lengthening and rapid distraction lengthening with a bone graft. However, gradual distraction is the preferred method due to excellent cosmetic outcomes and few postoperative complications. This article reports a case of brachymetacarpia treated with distraction lengthening using a minimally invasive, percutaneous approach. A 16-year-old girl presented with a shortened left ring finger and underwent surgery to correct the deformity. The left ring finger measured 12 mm shorter than her right ring finger; however, there was normal mobility at the joints. In the operating room, an external fixator was attached using 4 self-drilling, self-tapping pins through several 3-mm skin incisions. The total fixation time was 14 weeks; however, the achieved length of 12 mm was achieved 6 weeks postoperatively. The healing index of the fixation period was 81 days/cm. The postoperative course and fixation period were uneventful, with no complications except for 2 pin infections that were treated with oral antibiotics. The method of gradual distraction lengthening in this case successfully achieved the desired length and yielded an excellent cosmetic result. Copyright 2011, SLACK Incorporated.

  2. Development of a tactile display with 5 mm resolution using an array of magnetorheological fluid

    NASA Astrophysics Data System (ADS)

    Ishizuka, Hiroki; Miki, Norihisa

    2017-06-01

    In this study, we demonstrate the design and evaluation of a stiffness tactile display using a magnetorheological (MR) fluid. The tactile display is based on the change in mechanical properties under an external magnetic field. In the tactile display, the MR fluid is encapsulated in chambers of 3 mm diameter and arranged at intervals of 2 mm. Magnetic fields were spatially applied to the tactile display using neodymium magnets of 3.5 mm diameter. The design and spatial magnetic field application enable the tactile display to present stiff dots of 5 mm resolution. We confirmed that the tactile display can present a spatial stiff dot and its pattern on the surface by compression experiments. Sensory evaluation revealed that the users were able to perceive the approximate position of the stiff dots. From the experiments, the tactile display has potential as a palpation tactile display and requires improvement to present various types of tissues.

  3. Get the Message: A Teen Distracted Driving Program.

    PubMed

    Adeola, Ruth; Omorogbe, Ashleigh; Johnson, Abree

    Elimination of distracted driving is becoming a public health priority. Each day, an average of 8 people are killed due to a distracted driver in the United Sates. Although all drivers are at risk, research has indicated that teenage drivers are overrepresented in motor vehicle crashes due to distracted driving. Teenage drivers are hindered by limited driving experience, and the illusion of invincibility is a common phase in social and cognitive adolescent development. "Get the Message: A Teenage Distracted Driving Program" was established at the R Adams Cowley Shock Trauma Center to identify, define, and measure the factors that contribute to distracted driving in teens. A convenience sample of 1,238 teenagers in this study represented all 50 states in the United States, the District of Columbia, Puerto Rico, Canada, and 21 other countries. At the beginning of each program, a presurvey is administered to assess baseline behavior, attitude, and knowledge regarding distracted driving. After completing the program, teens complete a postsurvey to measure proposed changes in driving behaviors, attitude, and knowledge. The program employs the use of a slide presentation, hospital tour, video, and survivor's testimony to influence teen driving behaviors and increase knowledge. Research has indicated that an increase in the Health Belief Model constructs may enhance engagement in health-promoting behaviors, such as safe driving practices in teens. Based on the postsurvey results, the reduction in projected phone use while driving in this teen population indicates the effectiveness of this hospital-based teen distracted driving program.

  4. E-Pad: a comfortable electrocutaneous-based tactile feedback display

    NASA Astrophysics Data System (ADS)

    Wang, Jiabin; Zhao, Lu; Liu, Yue; Wang, Yongtian; Cai, Yi

    2018-01-01

    The devices with touchscreen are becoming more popular recently; however, most of them suffer from the crucial drawbacks of lacking accurate tactile feedback. A novel electrocutaneous-based tactile device with the name of E-pad is proposed to provide a dynamic and static low-voltage feedback for touchscreen. We optimize the key parameters of the output voltage and design custom-made hardwares to guarantee a comfortable user experience. Users could move their fingers freely across the touchscreen of the proposed device to really feel virtual objects. Two preliminary experiments are conducted to evaluate the interactive performance of the proposed device and the experimental results show that the proposed device can provide a comfortable and distinct tactile feedback.

  5. Tactile Sensitivity of Children: Effects of Frequency, Masking, and the Non-Pacinian I Psychophysical Channel

    ERIC Educational Resources Information Center

    Guclu, Burak; Oztek, Cigdem

    2007-01-01

    Tactile perception depends on the contributions of four psychophysical tactile channels mediated by four corresponding receptor systems. The sensitivity of the tactile channels is determined by detection thresholds that vary as a function of the stimulus frequency. It has been widely reported that tactile thresholds increase (i.e., sensitivity…

  6. The role of alcohol use on recent trends in distracted driving.

    PubMed

    Wilson, Fernando A; Stimpson, Jim P; Tibbits, Melissa K

    2013-11-01

    Distracted driving is now an increasingly deadly threat to road safety. We provide evidence that intoxicated driving is increasingly responsible for recent increases in fatalities from distracted driving crashes. This study describes trends in deaths on U.S. public roads caused by alcohol-involved and distracted drivers using the Fatality Analysis Reporting System (FARS)-a census of fatal crashes on U.S. public roads. Fatality rates per vehicle-miles traveled are calculated using data from the Federal Highway Administration. Alcohol-involved drivers who are simultaneously distracted were responsible for 1750 deaths in 2009, an increase of more than 63% from 2005 when there were 1072 deaths. Alcohol use while driving is increasingly responsible for a growing number of fatalities from distracted driving, accounting for 32% of deaths from distracted driving in 2009 versus 24% in 2005. The fatality rate from these crashes increased from 35.9 to 59.2 deaths per 100 billion vehicle-miles traveled after 2005. Alcohol use is quickly increasing as an important factor behind distracted driving fatalities. This has implications for policies combating distracted driving that do not address the role of alcohol use in distracted driving. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Change of reference frame for tactile localization during child development.

    PubMed

    Pagel, Birthe; Heed, Tobias; Röder, Brigitte

    2009-11-01

    Temporal order judgements (TOJ) for two tactile stimuli, one presented to the left and one to the right hand, are less precise when the hands are crossed over the midline than when the hands are uncrossed. This 'crossed hand' effect has been considered as evidence for a remapping of tactile input into an external reference frame. Since late, but not early, blind individuals show such remapping, it has been hypothesized that the use of an external reference frame develops during childhood. Five- to 10-year-old children were therefore tested with the tactile TOJ task, both with uncrossed and crossed hands. Overall performance in the TOJ task improved with age. While children older than 5 1/2 years displayed a crossed hand effect, younger children did not. Therefore the use of an external reference frame for tactile, and possibly multisensory, localization seems to be acquired at age 5.

  8. Multisensory effects on somatosensation: a trimodal visuo-vestibular-tactile interaction

    PubMed Central

    Kaliuzhna, Mariia; Ferrè, Elisa Raffaella; Herbelin, Bruno; Blanke, Olaf; Haggard, Patrick

    2016-01-01

    Vestibular information about self-motion is combined with other sensory signals. Previous research described both visuo-vestibular and vestibular-tactile bilateral interactions, but the simultaneous interaction between all three sensory modalities has not been explored. Here we exploit a previously reported visuo-vestibular integration to investigate multisensory effects on tactile sensitivity in humans. Tactile sensitivity was measured during passive whole body rotations alone or in conjunction with optic flow, creating either purely vestibular or visuo-vestibular sensations of self-motion. Our results demonstrate that tactile sensitivity is modulated by perceived self-motion, as provided by a combined visuo-vestibular percept, and not by the visual and vestibular cues independently. We propose a hierarchical multisensory interaction that underpins somatosensory modulation: visual and vestibular cues are first combined to produce a multisensory self-motion percept. Somatosensory processing is then enhanced according to the degree of perceived self-motion. PMID:27198907

  9. Motivation enhances control of positive and negative emotional distractions.

    PubMed

    Walsh, Amy T; Carmel, David; Harper, David; Grimshaw, Gina M

    2018-01-03

    Using cognitive control to ignore distractions is essential for successfully achieving our goals. In emotionally-neutral contexts, motivation can reduce interference from irrelevant stimuli by enhancing cognitive control. However, attention is commonly biased towards emotional stimuli, making them potent distractors. Can motivation aid control of emotional distractions, and does it do so similarly for positive and negative stimuli? Here, we examined how task motivation influences control of distraction from positive, negative, and neutral scenes. Participants completed a simple perceptual task while attempting to ignore task-irrelevant images. One group received monetary reward for fast and accurate task performance; another (control) group did not. Overall, both negative (mutilation) and positive (erotic) images caused greater slowing of responses than neutral images of people, but emotional distraction was reduced with reward. Crucially, despite the different motivational directions associated with negative and positive stimuli, reward reduced negative and positive distraction equally. Our findings suggest that motivation may encourage the use of a sustained proactive control strategy that can effectively reduce the impact of emotional distraction.

  10. Initial Experience With a New Intraoral Midface Distraction Device.

    PubMed

    Burstein, Fernando; Soldanska, Magdalena; Granger, Michael; Berhane, ChiChi; Schoemann, Mark

    2015-06-01

    Maxillary hypoplasia that necessitates surgical advancement affects approximately 25% of patients born with cleft lip and palate. Syndromic conditions such as Crouzon may also be accompanied by significant maxillary hypoplasia. Severe maxillary hypoplasia can result in airway obstruction, malocclusion, proptosis, and facial disfigurement. For optimal stability, severe hypoplasia is best addressed with maxillary distraction osteogenesis. Twenty-two patients (15 boys, 7 girls, ages 6-16 years, mean age 10 years) with severe midface hypoplasia underwent midface distraction with new internal maxillary distraction (IMD) device at our institution. Total distraction distances ranged from 15 to 30 mm. There were no major complications, and all of them had improvement in functional and aesthetic parameters. There were 2 minor complications and 2 patients failed to distract the full distance because of converging vectors. Early maxillary distraction in patients with severe midface hypoplasia is a useful technique to provide interval correction of severe maxillary hypoplasia before skeletal maturity and definitive orthognathic surgery is contemplated, and it is a good tool to improve occlusion, aesthetics, and self-perception in younger patients.

  11. Initial Experience With a New Intraoral Midface Distraction Device

    PubMed Central

    Burstein, Fernando; Soldanska, Magdalena; Granger, Michael; Berhane, ChiChi; Schoemann, Mark

    2015-01-01

    Abstract Maxillary hypoplasia that necessitates surgical advancement affects approximately 25% of patients born with cleft lip and palate. Syndromic conditions such as Crouzon may also be accompanied by significant maxillary hypoplasia. Severe maxillary hypoplasia can result in airway obstruction, malocclusion, proptosis, and facial disfigurement. For optimal stability, severe hypoplasia is best addressed with maxillary distraction osteogenesis. Twenty-two patients (15 boys, 7 girls, ages 6–16 years, mean age 10 years) with severe midface hypoplasia underwent midface distraction with new internal maxillary distraction (IMD) device at our institution. Total distraction distances ranged from 15 to 30 mm. There were no major complications, and all of them had improvement in functional and aesthetic parameters. There were 2 minor complications and 2 patients failed to distract the full distance because of converging vectors. Early maxillary distraction in patients with severe midface hypoplasia is a useful technique to provide interval correction of severe maxillary hypoplasia before skeletal maturity and definitive orthognathic surgery is contemplated, and it is a good tool to improve occlusion, aesthetics, and self-perception in younger patients. PMID:26080162

  12. A Tactile Stimulator for Studying Passive Shape Perception

    PubMed Central

    Lane, John W.; Fitzgerald, Paul J.; Yau, Jeffrey M.; Pembeci, Izzet; Hsiao, Steven S.

    2009-01-01

    We describe a computer-controlled tactile stimulator for use in human psychophysical and monkey neurophysiological studies of 3-D shape perception. The stimulator is constructed primarily of commercially available parts, as well as a few custom-built pieces for which we will supply diagrams upon request. There are two components to the stimulator: a tactile component and a hand positioner component. The tactile component consists of multiple stimulating units that move about in a Cartesian plane above the restrained hand. Each stimulating unit contains a servo-controlled linear motor with an attached small rotary stepper motor, allowing arbitrary stimulus shapes to contact the skin through vibration, static indentation, or scanning. The hand positioner component modifies the conformation of the restrained hand through a set of mechanical linkages under motorized control. The present design controls the amount of spread between digits two and three, the spread between digits four and three, and the degree to which digit three is flexed or extended, thereby simulating different conformations of the hand in contact with objects. This design is easily modified to suit the needs of the experimenter. Because the two components of the stimulator are independently controlled, the stimulator allows for parametric study of the mechanoreceptive and proprioceptive contributions to 3-D tactile shape perception. PMID:19800916

  13. Tactile short-term memory in sensory-deprived individuals.

    PubMed

    Papagno, Costanza; Minniti, Giovanna; Mattavelli, Giulia C; Mantovan, Lara; Cecchetto, Carlo

    2017-02-01

    To verify whether loosing a sense or two has consequences on a spared sensory modality, namely touch, and whether these consequences depend on practice or are biologically determined, we investigated 13 deafblind participants, 16 deaf participants, 15 blind participants, and 13 matched normally sighted and hearing controls on a tactile short-term memory task, using checkerboard matrices of increasing length in which half of the squares were made up of a rough texture and half of a smooth one. Time of execution of a fixed matrix, number of correctly reproduced matrices, largest matrix correctly reproduced and tactile span were recorded. The three groups of sensory-deprived individuals did not differ in any measure, while blind and deaf participants outscored controls in all parameters except time of execution; the difference approached significance for deafblind people compared to controls only in one measure, namely correctly reproduced matrices. In blind and deafblind participants, performance negatively correlated with age of Braille acquisition, the older being the subject when acquiring Braille, the lower the performance, suggesting that practice plays a role. However, the fact that deaf participants, who did not share tactile experience, performed similarly to blind participants and significantly better than controls highlights that practice cannot be the only contribution to better tactile memory.

  14. Structural design and output characteristic analysis of magnetostrictive tactile sensor for robotic applications

    NASA Astrophysics Data System (ADS)

    Zheng, Wendong; Wang, Bowen; Liu, Huaping; Li, Yunkai; Zhao, Ran; Weng, Ling; Zhang, Changgeng

    2018-05-01

    A novel magnetostrictive tactile sensor has been designed according to the transduction mechanism of cilia and Villari effect of iron-gallium alloy. The tactile sensor consists of a Galfenol beam, a pair of permanent magnets, a Hall sensor and a signal processing system. Compared with the conventional tactile sensor, our proposed tactile sensor can not only detect the contact-force, but also sense stiffness of an object. The performance and measurement range of tactile sensor have theoretically been analyzed and experimentally investigated. The results have revealed that the sensibility of tactile sensor for sensing force is up to 22.81mV/N at applied bias magnetic field of 2.56kA/m. Moreover, the sensor can effectively discriminate objects with different stiffness. The sensor is characterized by high sensitivity, good linearity, and quick response. It has the potential of being miniaturized and integrated into the finger of a robotic hand to realize force sensing and object recognition in real-time.

  15. Tactile massage as a nursing intervention in child and adolescent psychiatry: nurses' experiences.

    PubMed

    Robertz, A-C; Rudolfsson, G

    2016-10-01

    WHAT IS KNOWN ABOUT THE SUBJECT?: There is little research on the implementation of tactile massage in child and adolescent psychiatry that describes children's and adolescents' experiences and outcomes. There is also limited knowledge of providing tactile massage in child and adolescent psychiatry. WHAT DOES THIS PAPER ADD TO EXISTING KNOWLEDGE?: This paper describes 10 nurses' experiences of tactile massage as a nursing intervention in child and adolescent psychiatry. The nurses considered tactile massage a non-verbal nursing intervention that could complement other available treatments. It reveals their reflections on the impact of tactile massage on their nursing and on themselves as a person, including the belief that they had developed deepened self-reflection and attentiveness. The nurses highlighted the importance of providing a trusting environment and collaborating with the children and adolescents. They both experienced and observed that tactile massage triggered various physical and mental processes in the children and adolescents, such as improvement in sleep disturbances, an ability to relax in body and mind and a deeper connectedness with their own bodies and feelings. The nurses described instructing next of kin in the use of tactile massage, which they believed could serve as a tool at home, mainly as a way for next of kin to help their children to relax, fall asleep more easily and to deepen connectedness. However, the nurses stressed the need to consider if it was appropriate or desired by the children and adolescents. WHAT ARE THE IMPLICATIONS FOR PRACTICE?: Tactile massage addresses the individual's emotional and physiological responses and could therefore bring holistic nursing to child and adolescent psychiatry. It could also help nurses in child and adolescent psychiatry to develop their attentiveness and sensitivity in acknowledging the needs of children and adolescents in psychiatric care. Introduction There is limited research on tactile

  16. Constructing a publically available distracted driving database and research tool.

    PubMed

    Atchley, Paul; Tran, Ashleigh V; Salehinejad, Mohammad Ali

    2017-02-01

    The goal of the current work was to create a publicly available visualization tool of distracted driving research, the purpose of which is to allow the public and other stakeholders to empirically inform questions of their choice that may bear on policy discussions. Fifty years of distracted driving research was used to design a comprehensive database of studies that evaluated the effects of distraction on driving performance. Distraction sources (e.g., texting, talking, visual distraction) and performance measures were defined, and the sample of studies were evaluated and categorized by their measures. The final product yielded 342 studies using various methodologies. Across all measures, 1297 found distractions degraded driving performance, 54 found distraction improved driving performance, and 257 found distraction had no effect on driving performance. An analysis of the most common phone distractions (texting and talking) showed that texting almost always results in degraded performance. Aggregate data reveal no difference in performance decrements for hand-held or hands-free phones even though single studies of those variables vary in their outcomes. This project illustrates how scientific research can be made publically available for use by a diverse audience of stakeholders. An important result of this project is that data aggregated along a simple set of characteristics such as whether or not performance is decreased, improved or not affected, can reveal trends in the data that are less clear from any individual study. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Transsutural distraction osteogenesis applied to maxillary complex with new internalized distraction device: analysis of the feasibility and long-term osteogenesis outcome.

    PubMed

    Tong, Haizhou; Gao, Feng; Yin, Jiapeng; Zhang, Xiangyu; Zhang, Chen; Yin, Ningbei; Zhao, Zhenmin

    2015-03-01

    The purposes of this study were to evaluate the effects of transsutural distraction osteogenesis applied to the maxillary complex with a new internalized distraction device and to analyze the long-term osteogenesis outcome. Three-month-old beagle dogs were treated with a self-designed internalized distractor. The feasibility was evaluated, and the effects of the maxillary growth were measured using radiography and computed tomography (CT). The regenerated bone was examined with micro-CT, biomechanical testing, and histology 1 year after the distraction. The experimental group showed significantly larger forward displacement of maxillary during the distraction. One year after the distraction, the micro-CT showed more incompact structure and bone volume/total volume was significantly less in the experimental group. Biomechanical testing also showed a significantly lower yield but with no difference in stiffness. Histologic staining found osteoclasts deposited in the region of the suture and osteoblasts on the bone surface. The immunohistochemical staining of osteoprotegrin and receptor activator of nuclear factor-κ B ligand showed evidence of expression in suture area components and osteocytes with no difference between the groups. Transsutural distraction osteogenesis using an internalized distractor with skull anchorage demonstrated feasibility. It is expected that this device may provide new thoughts in developing an appropriate appliance for clinical use in young patients with midfacial hypoplasia. Moreover, the long-term osteogenesis analysis findings suggest that the metabolism of sutural area still remained active, which enhanced our understanding of bone remodeling in the sutural area to manage maxillary relapse after transsutural distraction osteogenesis.

  18. Normalizing memory recall in fibromyalgia with rehearsal: a distraction-counteracting effect.

    PubMed

    Leavitt, Frank; Katz, Robert S

    2009-06-15

    To examine the impact of distraction on the retention of rehearsed information in patients with fibromyalgia syndrome (FMS). Data refer to the neurocognitive examination of 134 patients (91 with FMS and 43 control subjects) presenting with memory loss. Four neurocognitive measures free of distraction, along with 2 measures with added distraction, were completed. Differences in the retention of rehearsed and unrehearsed information with a source of distraction present were calculated. Patients with FMS showed normal cognitive functioning on verbal memory tests free of distraction. Adding a source of distraction caused unrefreshed information to be lost at a disproportionate rate in patients with FMS. Over 87% of patients with FMS scored in the impaired range on a task of unrehearsed verbal memory. Adding a source of distraction to well-rehearsed information produced a normal rate of recall in FMS. Rehearsal mechanisms are intact in patients with FMS and play beneficial roles in managing interference from a source of distraction. In the absence of rehearsal, a source of distraction added to unrefreshed information signals a remarkable level of cognitive deficit in FMS that goes undetected by conventionally relied-upon neurocognitive measures. We present a theory to promote understanding of the cognitive deficit of people with FMS based on reduced speed of lexical activation and poor recall after distraction.

  19. Visual detail about the body modulates tactile localisation biases.

    PubMed

    Margolis, Aaron N; Longo, Matthew R

    2015-02-01

    The localisation of tactile stimuli requires the integration of visual and somatosensory inputs within an internal representation of the body surface and is prone to consistent bias. Joints may play a role in segmenting such internal body representations, and may therefore influence tactile localisation biases, although the nature of this influence remains unclear. Here, we investigate the relationship between conceptual knowledge of joint locations and tactile localisation biases on the hand. In one task, participants localised tactile stimuli applied to the dorsum of their hand. A distal localisation bias was observed in all participants, consistent with previous results. We also manipulated the availability of visual information during this task, to determine whether the absence of this information could account for the distal bias observed here and by Mancini et al. (Neuropsychologia 49:1194-1201, 2011). The observed distal bias increased in magnitude when visual information was restricted, without a corresponding decrease in precision. In a separate task, the same participants indicated, from memory, knuckle locations on a silhouette image of their hand. Analogous distal biases were also seen in the knuckle localisation task. The accuracy of conceptual joint knowledge was not correlated with tactile localisation bias magnitude, although a similarity in observed bias direction suggests that both tasks may rely on a common, higher-order body representation. These results also suggest that distortions of conceptual body representation may be more common in healthy individuals than previously thought.

  20. Short-Term Visual Deprivation, Tactile Acuity, and Haptic Solid Shape Discrimination

    PubMed Central

    Crabtree, Charles E.; Norman, J. Farley

    2014-01-01

    Previous psychophysical studies have reported conflicting results concerning the effects of short-term visual deprivation upon tactile acuity. Some studies have found that 45 to 90 minutes of total light deprivation produce significant improvements in participants' tactile acuity as measured with a grating orientation discrimination task. In contrast, a single 2011 study found no such improvement while attempting to replicate these earlier findings. A primary goal of the current experiment was to resolve this discrepancy in the literature by evaluating the effects of a 90-minute period of total light deprivation upon tactile grating orientation discrimination. We also evaluated the potential effect of short-term deprivation upon haptic 3-D shape discrimination using a set of naturally-shaped solid objects. According to previous research, short-term deprivation enhances performance in a tactile 2-D shape discrimination task – perhaps a similar improvement also occurs for haptic 3-D shape discrimination. The results of the current investigation demonstrate that not only does short-term visual deprivation not enhance tactile acuity, it additionally has no effect upon haptic 3-D shape discrimination. While visual deprivation had no effect in our study, there was a significant effect of experience and learning for the grating orientation task – the participants' tactile acuity improved over time, independent of whether they had, or had not, experienced visual deprivation. PMID:25397327

  1. Short-term visual deprivation, tactile acuity, and haptic solid shape discrimination.

    PubMed

    Crabtree, Charles E; Norman, J Farley

    2014-01-01

    Previous psychophysical studies have reported conflicting results concerning the effects of short-term visual deprivation upon tactile acuity. Some studies have found that 45 to 90 minutes of total light deprivation produce significant improvements in participants' tactile acuity as measured with a grating orientation discrimination task. In contrast, a single 2011 study found no such improvement while attempting to replicate these earlier findings. A primary goal of the current experiment was to resolve this discrepancy in the literature by evaluating the effects of a 90-minute period of total light deprivation upon tactile grating orientation discrimination. We also evaluated the potential effect of short-term deprivation upon haptic 3-D shape discrimination using a set of naturally-shaped solid objects. According to previous research, short-term deprivation enhances performance in a tactile 2-D shape discrimination task - perhaps a similar improvement also occurs for haptic 3-D shape discrimination. The results of the current investigation demonstrate that not only does short-term visual deprivation not enhance tactile acuity, it additionally has no effect upon haptic 3-D shape discrimination. While visual deprivation had no effect in our study, there was a significant effect of experience and learning for the grating orientation task - the participants' tactile acuity improved over time, independent of whether they had, or had not, experienced visual deprivation.

  2. Human detection and discrimination of tactile repeatability, mechanical backlash, and temporal delay in a combined tactile-kinesthetic haptic display system.

    PubMed

    Doxon, Andrew J; Johnson, David E; Tan, Hong Z; Provancher, William R

    2013-01-01

    Many of the devices used in haptics research are over-engineered for the task and are designed with capabilities that go far beyond human perception levels. Designing devices that more closely match the limits of human perception will make them smaller, less expensive, and more useful. However, many device-centric perception thresholds have yet to be evaluated. To this end, three experiments were conducted, using one degree-of-freedom contact location feedback device in combination with a kinesthetic display, to provide a more explicit set of specifications for similar tactile-kinesthetic haptic devices. The first of these experiments evaluated the ability of humans to repeatedly localize tactile cues across the fingerpad. Subjects could localize cues to within 1.3 mm and showed bias toward the center of the fingerpad. The second experiment evaluated the minimum perceptible difference of backlash at the tactile element. Subjects were able to discriminate device backlash in excess of 0.46 mm on low-curvature models and 0.93 mm on high-curvature models. The last experiment evaluated the minimum perceptible difference of system delay between user action and device reaction. Subjects were able to discriminate delays in excess of 61 ms. The results from these studies can serve as the maximum (i.e., most demanding) device specifications for most tactile-kinesthetic haptic systems.

  3. Concurrent emotional pictures modulate temporal order judgments of spatially separated audio-tactile stimuli.

    PubMed

    Jia, Lina; Shi, Zhuanghua; Zang, Xuelian; Müller, Hermann J

    2013-11-06

    Although attention can be captured toward high-arousal stimuli, little is known about how perceiving emotion in one modality influences the temporal processing of non-emotional stimuli in other modalities. We addressed this issue by presenting observers spatially uninformative emotional pictures while they performed an audio-tactile temporal-order judgment (TOJ) task. In Experiment 1, audio-tactile stimuli were presented at the same location straight ahead of the participants, who had to judge "which modality came first?". In Experiments 2 and 3, the audio-tactile stimuli were delivered one to the left and the other to the right side, and participants had to judge "which side came first?". We found both negative and positive high-arousal pictures to significantly bias TOJs towards the tactile and away from the auditory event when the audio-tactile stimuli were spatially separated; by contrast, there was no such bias when the audio-tactile stimuli originated from the same location. To further examine whether this bias is attributable to the emotional meanings conveyed by the pictures or to their high arousal effect, we compared and contrasted the influences of near-body threat vs. remote threat (emotional) pictures on audio-tactile TOJs in Experiment 3. The bias manifested only in the near-body threat condition. Taken together, the findings indicate that visual stimuli conveying meanings of near-body interaction activate a sensorimotor functional link prioritizing the processing of tactile over auditory signals when these signals are spatially separated. In contrast, audio-tactile signals from the same location engender strong crossmodal integration, thus counteracting modality-based attentional shifts induced by the emotional pictures. © 2013 Published by Elsevier B.V.

  4. Special Considerations in Distracted Driving with Teens

    PubMed Central

    Durbin, Dennis R; McGehee, Daniel V; Fisher, Donald; McCartt, Anne

    2014-01-01

    Novice teen drivers have long been known to have an increased risk of crashing, as well as increased tendencies toward unsafe and risky driving behaviors. Teens are unique as drivers for several reasons, many of which have implications specifically in the area of distracted driving. This paper reviews several of these features, including the widespread prevalence of mobile device use by teens, their lack of driving experience, the influence of peer passengers as a source of distraction, the role of parents in influencing teens’ attitudes and behaviors relevant to distracted driving and the impact of laws designed to prevent mobile device use by teen drivers. Recommendations for future research include understanding how engagement in a variety of secondary tasks by teen drivers affects their driving performance or crash risk; understanding the respective roles of parents, peers and technology in influencing teen driver behavior; and evaluating the impact of public policy on mitigating teen crash risk related to driver distraction. PMID:24776228

  5. Exploring the Invisible Universe: A Tactile and Braille Exhibit of Astronomical Images

    NASA Astrophysics Data System (ADS)

    Arcand, K. K.; Watzke, M.; de Pree, C.

    2010-06-01

    A tactile/Braille exhibit for the visually impaired community in the USA was launched in July 2009. The exhibit is part of the global From Earth to the Universe (FETTU) project, a Cornerstone of the International Year of Astronomy 2009. The science content of the travelling tactile/Braille exhibit includes explanations of our Sun, Eta Carinae, the Crab Nebula, the Whirlpool Galaxy and the electromagnetic spectrum, and was adapted from the tactile/Braille book Touch the Invisible Sky. We present some of the early observations and findings on the tactile/Braille FETTU exhibit. The new exhibit opens a wider door to experiencing and understanding astronomy for the underserved visually impaired population.

  6. Tactile display landing safety and precision improvements for the Space Shuttle

    NASA Astrophysics Data System (ADS)

    Olson, John M.

    A tactile display belt using 24 electro-mechanical tactile transducers (tactors) was used to determine if a modified tactile display system, known as the Tactile Situation Awareness System (TSAS) improved the safety and precision of a complex spacecraft (i.e. the Space Shuttle Orbiter) in guided precision approaches and landings. The goal was to determine if tactile cues enhance safety and mission performance through reduced workload, increased situational awareness (SA), and an improved operational capability by increasing secondary cognitive workload capacity and human-machine interface efficiency and effectiveness. Using both qualitative and quantitative measures such as NASA's Justiz Numerical Measure and Synwork1 scores, an Overall Workload (OW) measure, the Cooper-Harper rating scale, and the China Lake Situational Awareness scale, plus Pre- and Post-Flight Surveys, the data show that tactile displays decrease OW, improve SA, counteract fatigue, and provide superior warning and monitoring capacity for dynamic, off-nominal, high concurrent workload scenarios involving complex, cognitive, and multi-sensory critical scenarios. Use of TSAS for maintaining guided precision approaches and landings was generally intuitive, reduced training times, and improved task learning effects. Ultimately, the use of a homogeneous, experienced, and statistically robust population of test pilots demonstrated that the use of tactile displays for Space Shuttle approaches and landings with degraded vehicle systems, weather, and environmental conditions produced substantial improvements in safety, consistency, reliability, and ease of operations under demanding conditions. Recommendations for further analysis and study are provided in order to leverage the results from this research and further explore the potential to reduce the risk of spaceflight and aerospace operations in general.

  7. The Role of Work Identity in Women's Adjustment to Divorce.

    ERIC Educational Resources Information Center

    Bisagni, Gina M.; Eckenrode, John

    This study explored the role of employment as a focus of identity in women's divorce adjustment. Based on data from 40 semi-structured interviews, four salient aspects of the worker's role were measured: (1) meaningfulness; (2) social interaction/support; (3) productivity; and (4) positive distraction. Work identity was associated with higher…

  8. Establishing Auditory-Tactile-Visual Equivalence Classes in Children with Autism and Developmental Delays

    ERIC Educational Resources Information Center

    Mullen, Stuart; Dixon, Mark R.; Belisle, Jordan; Stanley, Caleb

    2017-01-01

    The current study sought to evaluate the efficacy of a stimulus equivalence training procedure in establishing auditory-tactile-visual stimulus classes with 2 children with autism and developmental delays. Participants were exposed to vocal-tactile (A-B) and tactile-picture (B-C) conditional discrimination training and were tested for the…

  9. Distracted driving in elderly and middle-aged drivers.

    PubMed

    Thompson, Kelsey R; Johnson, Amy M; Emerson, Jamie L; Dawson, Jeffrey D; Boer, Erwin R; Rizzo, Matthew

    2012-03-01

    Automobile driving is a safety-critical real-world example of multitasking. A variety of roadway and in-vehicle distracter tasks create information processing loads that compete for the neural resources needed to drive safely. Drivers with mind and brain aging may be particularly susceptible to distraction due to waning cognitive resources and control over attention. This study examined distracted driving performance in an instrumented vehicle (IV) in 86 elderly (mean=72.5 years, SD=5.0 years) and 51 middle-aged drivers (mean=53.7 years, SD=9.3 year) under a concurrent auditory-verbal processing load created by the Paced Auditory Serial Addition Task (PASAT). Compared to baseline (no-task) driving performance, distraction was associated with reduced steering control in both groups, with middle-aged drivers showing a greater increase in steering variability. The elderly drove slower and showed decreased speed variability during distraction compared to middle-aged drivers. They also tended to "freeze up", spending significantly more time holding the gas pedal steady, another tactic that may mitigate time pressured integration and control of information, thereby freeing mental resources to maintain situation awareness. While 39% of elderly and 43% of middle-aged drivers committed significantly more driving safety errors during distraction, 28% and 18%, respectively, actually improved, compatible with allocation of attention resources to safety critical tasks under a cognitive load. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Distracted Driving in Elderly and Middle-Aged Drivers

    PubMed Central

    Thompson, Kelsey R.; Johnson, Amy M.; Emerson, Jamie L.; Dawson, Jeffrey D.; Boer, Erwin R.

    2011-01-01

    Automobile driving is a safety-critical real-world example of multitasking. A variety of roadway and in-vehicle distracter tasks create information processing loads that compete for the neural resources needed to drive safely. Drivers with mind and brain aging may be particularly susceptible to distraction due to waning cognitive resources and control over attention. This study examined distracted driving performance in an instrumented vehicle (IV) in 86 elderly (mean = 72.5 years, SD = 5.0 years) and 51 middle-aged drivers (mean = 53.7 years, SD = 9.3 year) under a concurrent auditory-verbal processing load created by the Paced Auditory Serial Addition Task (PASAT). Compared to baseline (no-task) driving performance, distraction was associated with reduced steering control in both groups, with middle-aged drivers showing a greater increase in steering variability. The elderly drove slower and showed decreased speed variability during distraction compared to middle-aged drivers. They also tended to “freeze up”, spending significantly more time holding the gas pedal steady, another tactic that may mitigate time pressured integration and control of information, thereby freeing mental resources to maintain situation awareness. While 39% of elderly and 43% of middle-aged drivers committed significantly more driving safety errors during distraction, 28% and 18%, respectively, actually improved, compatible with allocation of attention resources to safety critical tasks under a cognitive load. PMID:22269561

  11. Tactile Perception in Adults with Autism: A Multidimensional Psychophysical Study

    ERIC Educational Resources Information Center

    Cascio, Carissa; McGlone, Francis; Folger, Stephen; Tannan, Vinay; Baranek, Grace; Pelphrey, Kevin A.; Essick, Gregory

    2008-01-01

    Although sensory problems, including unusual tactile sensitivity, are heavily associated with autism, there is a dearth of rigorous psychophysical research. We compared tactile sensation in adults with autism to controls on the palm and forearm, the latter innervated by low-threshold unmyelinated afferents subserving a social/affiliative…

  12. [Stimulation and evaluation on maxillary distraction osteogenesis using CASSOS 2001].

    PubMed

    Zhu, Min; Qiu, Wei-liu; Tang, You-sheng; Li, Qing-yun

    2002-09-01

    To simulate maxillary distraction osteogenesis and evaluate the change of soft and hard tissue before and after treatment, using Computer-Assisted Simulation System for Orthognathic Surgery( CASSOS 2001). A fourteen-year-old boy with severe maxillary hypoplasia, due to unilateral cleft lip and palate, was analysed by cephalometric analysis. The simulations of maxillary distraction osteogenesis (Le Fort I osteotomy and Le Fort II osteotomy) were re-analysed. After the treatment, cephalometric analysis was preformed again. The data were compared. The maxillary hypoplasia was well treated using maxillary distraction osteogenesis; Compared with Le fort I osteotomy, more satisfactory results can be obtained by Le fort I distraction osteogenesis. Maxillary distraction osteogenesis is a better way to treat severe maxillary hypoplasia with operated CLP than maxillary osteotomy. CASSOS 2001 can help surgeons and patients on simulation and evaluation of maxillary distraction osteogenesis, and on decision of treatment plan.

  13. Neuromimetic Event-Based Detection for Closed-Loop Tactile Feedback Control of Upper Limb Prostheses

    PubMed Central

    Osborn, Luke; Kaliki, Rahul; Soares, Alcimar; Thakor, Nitish

    2016-01-01

    Upper limb amputees lack the valuable tactile sensing that helps provide context about the surrounding environment. Here we utilize tactile information to provide active touch feedback to a prosthetic hand. First, we developed fingertip tactile sensors for producing biomimetic spiking responses for monitoring contact, release, and slip of an object grasped by a prosthetic hand. We convert the sensor output into pulses, mimicking the rapid and slowly adapting spiking responses of receptor afferents found in the human body. Second, we designed and implemented two neuromimetic event-based algorithms, Compliant Grasping and Slip Prevention, on a prosthesis to create a local closed-loop tactile feedback control system (i.e. tactile information is sent to the prosthesis). Grasping experiments were designed to assess the benefit of this biologically inspired neuromimetic tactile feedback to a prosthesis. Results from able-bodied and amputee subjects show the average number of objects that broke or slipped during grasping decreased by over 50% and the average time to complete a grasping task decreased by at least 10% for most trials when comparing neuromimetic tactile feedback with no feedback on a prosthesis. Our neuromimetic method of closed-loop tactile sensing is a novel approach to improving the function of upper limb prostheses. PMID:27777640

  14. When Content Matters: The Role of Processing Code in Tactile Display Design.

    PubMed

    Ferris, Thomas K; Sarter, Nadine

    2010-01-01

    The distribution of tasks and stimuli across multiple modalities has been proposed as a means to support multitasking in data-rich environments. Recently, the tactile channel and, more specifically, communication via the use of tactile/haptic icons have received considerable interest. Past research has examined primarily the impact of concurrent task modality on the effectiveness of tactile information presentation. However, it is not well known to what extent the interpretation of iconic tactile patterns is affected by another attribute of information: the information processing codes of concurrent tasks. In two driving simulation studies (n = 25 for each), participants decoded icons composed of either spatial or nonspatial patterns of vibrations (engaging spatial and nonspatial processing code resources, respectively) while concurrently interpreting spatial or nonspatial visual task stimuli. As predicted by Multiple Resource Theory, performance was significantly worse (approximately 5-10 percent worse) when the tactile icons and visual tasks engaged the same processing code, with the overall worst performance in the spatial-spatial task pairing. The findings from these studies contribute to an improved understanding of information processing and can serve as input to multidimensional quantitative models of timesharing performance. From an applied perspective, the results suggest that competition for processing code resources warrants consideration, alongside other factors such as the naturalness of signal-message mapping, when designing iconic tactile displays. Nonspatially encoded tactile icons may be preferable in environments which already rely heavily on spatial processing, such as car cockpits.

  15. A flexible tactile sensitive sheet using a hetero-core fiber optic sensor

    NASA Astrophysics Data System (ADS)

    Fujino, S.; Yamazaki, H.; Hosoki, A.; Watanabe, K.

    2014-05-01

    In this report, we have designed a tactile sensitive sheet based on a hetero-core fiber-optic sensor, which realize an areal sensing by using single sensor potion in one optical fiber line. Recently, flexible and wide-area tactile sensing technology is expected to applied to acquired biological information in living space and robot achieve long-term care services such as welfare and nursing-care and humanoid technology. A hetero-core fiber-optic sensor has several advantages such as thin and flexible transmission line, immunity to EMI. Additionally this sensor is sensitive to moderate bending actions with optical loss changes and is independent of temperature fluctuation. Thus, the hetero-core fiber-optic sensor can be suitable for areal tactile sensing. We measure pressure characteristic of the proposed sensitive sheet by changing the pressure position and pinching characteristic on the surface. The proposed tactile sensitive sheet shows monotonic responses on the whole sensitive sheet surface although different sensitivity by the position is observed at the sensitive sheet surface. Moreover, the tactile sensitive sheet could sufficiently detect the pinching motion. In addition, in order to realize the discrimination between pressure and pinch, we fabricated a doubled-over sensor using a set of tactile sensitive sheets, which has different kinds of silicon robbers as a sensitive sheet surface. In conclusion, the flexible material could be given to the tactile sensation which is attached under proposed sensitive sheet.

  16. Exploring potential social influences on brain potentials during anticipation of tactile stimulation.

    PubMed

    Shen, Guannan; Saby, Joni N; Drew, Ashley R; Marshall, Peter J

    2017-03-15

    This study explored interpersonal influences on electrophysiological responses during the anticipation of tactile stimulation. It is well-known that broad, negative-going potentials are present in the event-related potential (ERP) between a forewarning cue and a tactile stimulus. It has also been shown that the alpha-range mu rhythm shows a lateralized desynchronization over central electrode sites during anticipation of tactile stimulation of the hand. The current study used a tactile discrimination task in which a visual cue signaled that an upcoming stimulus would either be delivered 1500ms later to the participant's hand, to a task partner's hand, or to neither person. For the condition in which participants anticipated the tactile stimulation to their own hand, a negative potential (contingent negative variation, CNV) was observed in the ERP at central sites in the 1000ms prior to the tactile stimulus. Significant mu rhythm desynchronization was also present in the same time window. The magnitudes of the ERPs and of the mu desynchronization were greater in the contralateral than in the ipsilateral hemisphere prior to right hand stimulation. Similar ERP and EEG changes were not present when the visual cue indicated that stimulation would be delivered to the task partner or to neither person. The absence of social influences during anticipation of tactile stimulation, and the relationship between the two brain signatures of anticipatory attention (CNV and mu rhythm) are discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Teens' distracted driving behavior: Prevalence and predictors.

    PubMed

    Gershon, Pnina; Zhu, Chunming; Klauer, Sheila G; Dingus, Tom; Simons-Morton, Bruce

    2017-12-01

    Teen drivers' over-involvement in crashes has been attributed to a variety of factors, including distracted driving. With the rapid development of in-vehicle systems and portable electronic devices, the burden associated with distracted driving is expected to increase. The current study identifies predictors of secondary task engagement among teenage drivers and provides basis for interventions to reduce distracted driving behavior. We described the prevalence of secondary tasks by type and driving conditions and evaluated the associations between the prevalence of secondary task engagement, driving conditions, and selected psychosocial factors. The private vehicles of 83 newly-licensed teenage drivers were equipped with Data Acquisition Systems (DAS), which documented driving performance measures, including secondary task engagement and driving environment characteristics. Surveys administered at licensure provided psychosocial measures. Overall, teens engaged in a potentially distracting secondary task in 58% of sampled road clips. The most prevalent types of secondary tasks were interaction with a passenger, talking/singing (no passenger), external distraction, and texting/dialing the cell phone. Secondary task engagement was more prevalent among those with primary vehicle access and when driving alone. Social norms, friends' risky driving behaviors, and parental limitations were significantly associated with secondary task prevalence. In contrast, environmental attributes, including lighting and road surface conditions, were not associated with teens' engagement in secondary tasks. Our findings indicated that teens engaged in secondary tasks frequently and poorly regulate their driving behavior relative to environmental conditions. Practical applications: Peer and parent influences on secondary task engagement provide valuable objectives for countermeasures to reduce distracted driving among teenage drivers. Copyright © 2017 National Safety Council and

  18. Effect of cell phone distraction on pediatric pedestrian injury risk.

    PubMed

    Stavrinos, Despina; Byington, Katherine W; Schwebel, David C

    2009-02-01

    Early adolescents are using cell phones with increasing frequency. Cell phones are known to distract motor vehicle drivers to the point that their safety is jeopardized, but it is unclear if cell phones might also distract child pedestrians. This study was designed to examine the influence of talking on a cell phone for pediatric pedestrian injury risk. Seventy-seven children aged 10 to 11 years old completed simulated road crossings in an immersive, interactive virtual pedestrian environment. In a within-subjects design, children crossed the virtual street 6 times while undistracted and 6 times while distracted by a cell phone conversation with an unfamiliar research assistant. Participants also completed several other experimental tasks hypothesized to predict the impact of distraction while crossing the street and talking on a cell phone. Children's pedestrian safety was compromised when distracted by a cell phone conversation. While distracted, children were less attentive to traffic; left less safe time between their crossing and the next arriving vehicle; experienced more collisions and close calls with oncoming traffic; and waited longer before beginning to cross the street. Analyses testing experience using a cell phone and experience as a pedestrian yielded few significant results, suggesting that distraction on the cell phone might affect children's pedestrian safety no matter what their experience level. There was some indication that younger children and children who are less attentive and more oppositional may be slightly more susceptible to distraction while talking on the cell phone than older, more attentive, and less oppositional children. Our results suggest that cell phones distract preadolescent children while crossing streets.

  19. Investigation and modification of a commercially available tactile sensor suited for robotic applications. Thesis

    NASA Technical Reports Server (NTRS)

    Creus, Carolina

    1991-01-01

    Active (dynamic) tactile sensing was explored using a commercially available tactile array sensor. This task requires the redesign of the sensor interface and a full understanding of the old sensor hardware implementation. There were different stages to this research; the first stage involved the reverse engineering of the old tactile sensor. The second stage had to do with the exploration of the characteristics and behavior of the tactile sensor pad. The next stage dealt with the redesign of the sensor interface using the knowledge gained from the previous two stages. Finally, in the last stage, software to control the tactile sensor was developed to aid in the data acquisition process.

  20. Can Tactile Sensory Processing Differentiate Between Children with Autistic Disorder and Asperger's Disorder?

    PubMed Central

    2011-01-01

    Objective There are debates whether autistic disorder (autism) and Asperger's disorder are two distinct disorders. Moreover, interventional sensory occupational therapy should consider the clinical characteristics of patients. Already, commonalities and differences between Asperger's disorder and autistic disorder are not well studied. The aim of this study is to compare tactile sensory function of children with autistic disorder and children with Asperger's disorder. Methods Tactile sensory function was compared between 36 children with autism and 19 children with Asperger's disorder. The two disorders were diagnosed based on Diagnostic and Statistical Manual of Mental Disorders Fourth Edition, Text Revision. The parent-reported Tactile Dysfunction Checklist was used to assess the three aspects of hypersensitivity, hyposensitivity, and poor tactile perception and discrimination. Developmental coordination was also assessed. Results Developmental coordination problems total score was not associated with group. The mean (standard deviation) score of tactile hyper-responsivity was not different between the groups. Tactile hyporesponsivity and poor tactile perception and discrimination scores were statistically higher in autistic disorder than Asperger's disorder group. Conclusion These results for the first time indicated that at least some aspects of tactile perception can differentiate these two disorders. Children with autistic disorder have more tactile sensory seeking behaviors than children with Asperger's disorder. Moreover, the ability of children with autistic disorder for tactile discrimination and sensory perception is less than those with Asperger's disorder. Interventional sensory therapy in children with autistic disorder should have some characteristics that can be different and specific for children with Asperger's disorder. Formal intelligence quotient testing was not performed on all of the children evaluated, which is a limitation to this study. In

  1. Market study: Tactile paging system

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A market survey was conducted regarding the commercialization potential and key market factors relevant to a tactile paging system for deaf-blind people. The purpose of the tactile paging system is to communicate to the deaf-blind people in an institutional environment. The system consists of a main console and individual satellite wrist units. The console emits three signals by telemetry to the wrist com (receiving unit) which will measure approximately 2 x 4 x 3/4 inches and will be fastened to the wrist by a strap. The three vibration signals are fire alarm, time period indication, and a third signal which will alert the wearer of the wrist com to the fact that the pin on the top of the wrist is emitting a morse coded message. The Morse code message can be felt and recognized with the finger.

  2. A new distraction arthroplasty device using magnetic force; a cadaveric study.

    PubMed

    Kamei, Goki; Ochi, Mitsuo; Okuhara, Atsushi; Fujimiya, Mineko; Deie, Masataka; Adachi, Nobuo; Nakamae, Atsuo; Nakasa, Tomoyuki; Ohkawa, Shingo; Takazawa, Kobun; Eguchi, Akio; Katou, Tomohiro; Takada, Tsuyoshi; Usman, Muhammad Andry

    2013-04-01

    It is difficult for an articular cartilage injury to repair spontaneously. There are many procedures for treating cartilage injury, however there is no standard procedure for middle-aged patients who have diffuse knee osteoarthritis, especially of the lateral compartment. Therefore, Ochi developed a new distraction device that uses magnetic power to enlarge a joint space and promote cartilage regeneration with microfracture. The purpose of this study is to evaluate this new distraction arthroplasty system by using the cadaveric knee. This study used ten knees from six cadavers that were embalmed by Thiel's methods. The medial and lateral joint space was measured by AP radiographic view before and after distraction, and after weight-bearing to evaluate the joint distraction. The contact pressure of the medial and lateral compartments at the knee extension position by using a prescale film system was measured before and after weight-bearing with a 15 or 30-kg weight-bearing load to evaluate the effectiveness of this device. The lateral joint space significantly increased from the pre-distraction to the post-distraction; however, it did not change significantly between post-distraction and post-weight-bearing. With a 15 or 30-kg weight-bearing load, the contact pressure of the lateral compartment significantly decreased from the pre-distraction to the post-distraction. The most important advantage of this device is that it maintains a continuous distraction tension and enables almost the full range of motion of the knee. We believe that joint distraction by using magnetic force can be a promising option for cartilage injury in middle-aged patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Tactile Functioning in Children Who Are Blind: A Clinical Perspective

    ERIC Educational Resources Information Center

    Withagen, Ans; Vervloed, Mathijs P. J.; Janssen, Neeltje M.; Knoors, Harry; Verhoeven, Ludo

    2010-01-01

    This study of 48 children with congenital blindness who attended mainstream schools focused on the tactile and haptic skills they needed in typical academic and everyday tasks. The results showed that, in general, the children mastered such tactile tasks, but some items posed special problems. (Contains 4 tables.)

  4. A Prototype Tactile Sensor Array.

    DTIC Science & Technology

    1982-09-15

    Active Touch Sensing. Technical Report, MIT Artificial Inteligence Laboratory, 1981. (9] Larcombe, M. Carbon Fibre Tactile Sensors. Technical Report...thesis, Carnegie-Mellon University, 1981. [13] Purbrick, John A. A Force Transducer Employing Conductive Silicone Rubber. Technical Report, MIT Artificial

  5. Flexible PZT Thin Film Tactile Sensor for Biomedical Monitoring

    PubMed Central

    Tseng, Hong-Jie; Tian, Wei-Cheng; Wu, Wen-Jong

    2013-01-01

    This paper presents the development of tactile sensors using the sol-gel process to deposit a PZT thin-film from 250 nm to 1 μm on a flexible stainless steel substrate. The PZT thin-film tactile sensor can be used to measure human pulses from several areas, including carotid, brachial, finger, ankle, radial artery, and the apical region. Flexible PZT tactile sensors can overcome the diverse topology of various human regions and sense the corresponding signals from human bodies. The measured arterial pulse waveform can be used to diagnose hypertension and cardiac failure in patients. The proposed sensors have several advantages, such as flexibility, reliability, high strain, low cost, simple fabrication, and low temperature processing. The PZT thin-film deposition process includes a pyrolysis process at 150 °C/500 °C for 10/5 min, followed by an annealing process at 650 °C for 10 min. Finally, the consistent pulse wave velocity (PWV) was demonstrated based on human pulse measurements from apical to radial, brachial to radial, and radial to ankle. It is characterized that the sensitivity of our PZT-based tactile sensor was approximately 0.798 mV/g. PMID:23698262

  6. Flexible PZT thin film tactile sensor for biomedical monitoring.

    PubMed

    Tseng, Hong-Jie; Tian, Wei-Cheng; Wu, Wen-Jong

    2013-04-25

    This paper presents the development of tactile sensors using the sol-gel process to deposit a PZT thin-film from 250 nm to 1 μm on a flexible stainless steel substrate. The PZT thin-film tactile sensor can be used to measure human pulses from several areas, including carotid, brachial, finger, ankle, radial artery, and the apical region. Flexible PZT tactile sensors can overcome the diverse topology of various human regions and sense the corresponding signals from human bodies. The measured arterial pulse waveform can be used to diagnose hypertension and cardiac failure in patients. The proposed sensors have several advantages, such as flexibility, reliability, high strain, low cost, simple fabrication, and low temperature processing. The PZT thin-film deposition process includes a pyrolysis process at 150 °C/500 °C for 10/5 min, followed by an annealing process at 650 °C for 10 min. Finally, the consistent pulse wave velocity (PWV) was demonstrated based on human pulse measurements from apical to radial, brachial to radial, and radial to ankle. It is characterized that the sensitivity of our PZT-based tactile sensor was approximately 0.798 mV/g.

  7. Safety climate and the distracted driving experiences of truck drivers.

    PubMed

    Swedler, David I; Pollack, Keshia M; Agnew, Jacqueline

    2015-07-01

    For truck drivers, distracted driving is a workplace behavior that increases occupational injury risk. We propose safety climate as an appropriate lens through which researchers can examine occupational distracted driving. Using a mixed methods study design, we surveyed truck drivers using the Safety Climate Questionnaire (SCQ) complemented by semi-structured interviews of experts on distracted driving and truck safety. Safety climate was assessed by using the entire SCQ as an overall climate score, followed by factor analysis that identified the following safety climate factors: Communications and Procedures; Management Commitment; and Work Pressure. In multivariate regression, the overall safety climate scale was associated with having ever experienced a crash and/or distraction-involved swerving. Interview participants described how these SCQ constructs could affect occupational distracted driving. To reduce distraction-related crashes in their organizations, management can adhere to safe policies and procedures, invest in engineering controls, and develop safer communication procedures. © 2015 Wiley Periodicals, Inc.

  8. Divided attention reduces resistance to distraction at encoding but not retrieval.

    PubMed

    Weeks, Jennifer C; Hasher, Lynn

    2017-08-01

    Older adults show implicit memory for previously seen distraction, an effect attributed to poor attentional control. It is unclear whether this effect results from lack of control over encoding during the distraction task, lack of retrieval constraint during the test task, or both. In the present study, we simulated poor distraction control in young adults using divided attention at encoding, at retrieval, at both times, or not at all. The encoding task was a 1-back task on pictures with distracting superimposed letter strings, some of which were words. The retrieval task was a word fragment completion task testing implicit memory for the distracting words. Attention was divided using an auditory odd digit detection task. Dividing attention at encoding, but not at retrieval, resulted in significant priming for distraction, which suggests that control over encoding processes is a primary determinant of distraction transfer in populations with low inhibitory control (e.g. older adults).

  9. Maxillary Distraction Osteogenesis in Unilateral Cleft Lip and Palate Patients with Rigid External Distraction System.

    PubMed

    Alkhouri, Shadi; Waite, Peter D; Davis, Matthew B; Lamani, Ejvis; Kau, Chung How

    2017-01-01

    Distraction osteogenesis (DO) is a treatment option for patients with maxillary hypoplasia secondary to cleft lip and palate (CLP). The aim of this study is to present a technique for maxillary DO using Le Fort I osteotomy with rigid external distraction (RED) system. The patient presented in this paper was an Asian female with CLP aged 13 years and 6 months. She presented with severe midfacial deficiency with a Class III dental malocclusion with a negative overjet and concave facial profile. Cone-beam computed tomography images were recorded preoperatively and the operation performed involved a high Le Fort I osteotomy. The appliance fabricated was banded to upper first molars used for anchorage of the RED system. Distraction of the maxilla was initiated after 7-day latency period. Postoperative cephalometric analysis showed maxillary advancement anteriorly and superiorly, the total distraction treatment period was 10 days. The maxillary advancement was 10.5 mm and the SNA angle increased from 67.5° to 77.9°. Furthermore, the ANB angle changed from -9.8° to 1.6° and the occlusion changed from Class III to Class I. The profile of the face changed from concave to convex and a much better esthetic result was achieved. The study suggests RED system to be a reliable alternative procedure for the treatment of midfacial hypoplasia with or without cleft. Furthermore, it minimizes the risk of the surgical procedure and shortens the operating time.

  10. Tactile-Foot Stimulation Can Assist the Navigation of People with Visual Impairment

    PubMed Central

    Velázquez, Ramiro; Pissaloux, Edwige; Lay-Ekuakille, Aimé

    2015-01-01

    Background. Tactile interfaces that stimulate the plantar surface with vibrations could represent a step forward toward the development of wearable, inconspicuous, unobtrusive, and inexpensive assistive devices for people with visual impairments. Objective. To study how people understand information through their feet and to maximize the capabilities of tactile-foot perception for assisting human navigation. Methods. Based on the physiology of the plantar surface, three prototypes of electronic tactile interfaces for the foot have been developed. With important technological improvements between them, all three prototypes essentially consist of a set of vibrating actuators embedded in a foam shoe-insole. Perceptual experiments involving direction recognition and real-time navigation in space were conducted with a total of 60 voluntary subjects. Results. The developed prototypes demonstrated that they are capable of transmitting tactile information that is easy and fast to understand. Average direction recognition rates were 76%, 88.3%, and 94.2% for subjects wearing the first, second, and third prototype, respectively. Exhibiting significant advances in tactile-foot stimulation, the third prototype was evaluated in navigation tasks. Results show that subjects were capable of following directional instructions useful for navigating spaces. Conclusion. Footwear providing tactile stimulation can be considered for assisting the navigation of people with visual impairments. PMID:27019593

  11. Tactile-Foot Stimulation Can Assist the Navigation of People with Visual Impairment.

    PubMed

    Velázquez, Ramiro; Pissaloux, Edwige; Lay-Ekuakille, Aimé

    2015-01-01

    Background. Tactile interfaces that stimulate the plantar surface with vibrations could represent a step forward toward the development of wearable, inconspicuous, unobtrusive, and inexpensive assistive devices for people with visual impairments. Objective. To study how people understand information through their feet and to maximize the capabilities of tactile-foot perception for assisting human navigation. Methods. Based on the physiology of the plantar surface, three prototypes of electronic tactile interfaces for the foot have been developed. With important technological improvements between them, all three prototypes essentially consist of a set of vibrating actuators embedded in a foam shoe-insole. Perceptual experiments involving direction recognition and real-time navigation in space were conducted with a total of 60 voluntary subjects. Results. The developed prototypes demonstrated that they are capable of transmitting tactile information that is easy and fast to understand. Average direction recognition rates were 76%, 88.3%, and 94.2% for subjects wearing the first, second, and third prototype, respectively. Exhibiting significant advances in tactile-foot stimulation, the third prototype was evaluated in navigation tasks. Results show that subjects were capable of following directional instructions useful for navigating spaces. Conclusion. Footwear providing tactile stimulation can be considered for assisting the navigation of people with visual impairments.

  12. Distraction osteogenesis of costochondral bone grafts in the mandible.

    PubMed

    Stelnicki, Eric J; Hollier, Larry; Lee, Catherine; Lin, Wen-Yuan; Grayson, Barry; McCarthy, Joseph G

    2002-03-01

    Costochondral grafting for reconstruction of the Pruzansky type III mandible has given variable results. Lengthening of the rib graft by means of distraction had been advocated when subsequent growth of the grafted mandible is inadequate. This retrospective study reviews a series of patients with mandibular costochondral grafts who underwent subsequent distraction osteogenesis of the graft. A retrospective review identified two patient groups: group 1 consisted of individuals (n = 9) who underwent costochondral rib grafting of the mandible followed by distraction osteogenesis several months later at a rate of 1 mm/day. Group 2 consisted of patients with Pruzansky type II mandibles who had distraction osteogenesis without prior rib grafting (n = 9). The biomechanical parameters, orthodontic treatment regimens, and complications were examined versus patient age and quality of the rib graft. Distraction osteogenesis was successfully performed in six of the rib graft patients (group 1) and in all of the group 2 individuals. On the basis of the Haminishi scale, the computed tomographic scan appearance of the regenerate was classified as "standard or external" in six of the group 1 patients and as either "agenetic" or "pillar" (fibrous union) in the remaining three patients. In group 1, the average device was expanded 23 mm (range, 20 to 30 mm). Group 2 mandibular distraction results were all classified as either standard or external, and there was an average device expansion of 22.4 mm (range, 16 to 30 mm). The length of consolidation averaged 12.6 weeks in group 1, compared with 8.5 weeks in the traditional mandibular distraction patients (group 2). The mean shift of the dental midline to the contralateral side was 2.5 mm in group 1 versus 4.0 mm in group 2. Complex multiplanar and transport distractions were successfully performed on grafts of adequate bony volume. All four patients in group 1 with tracheostomies were successfully decannulated after consolidation. Rib

  13. Clinical Use of Deferoxamine in Distraction Osteogenesis of Irradiated Bone

    PubMed Central

    Momeni, Arash; Rapp, Scott; Donneys, Alexis; Buchman, Steven R.; Wan, Derrick C.

    2016-01-01

    The deleterious effects of radiotherapy, including hypovascularity and hypocellularity, have made distraction of irradiated bones challenging. Animal studies, however, have demonstrated adjunctive measures such as the administration of deferoxamine to significantly improve bone regeneration across irradiated distraction gaps. In this report, we demonstrate, for the first time, enhanced bone formation following deferoxamine application in a patient following distraction of a previously irradiated maxilla. CT imaging of the pterygomaxillary buttress on the side of administration revealed significantly increased bone area and density relative to the contralateral buttress. This is the first presentation of clinical deferoxamine use to promote bone formation following irradiated bone distraction and highlights the promise for this adjunctive measure to make outcomes after distraction of irradiated bone more reliable. PMID:27171947

  14. Stem cells rejuvenate radiation-impaired vasculogenesis in murine distraction osteogenesis.

    PubMed

    Deshpande, Sagar S; Gallagher, Kathleen K; Donneys, Alexis; Nelson, Noah S; Guys, Nicholas P; Felice, Peter A; Page, Erin E; Sun, Hongli; Krebsbach, Paul H; Buchman, Steven R

    2015-03-01

    Radiotherapy is known to be detrimental to bone and soft-tissue repair. Bone marrow stromal cells have been shown to enhance bone regeneration during distraction osteogenesis following radiation therapy. The authors posit that transplanted bone marrow stromal cells will significantly augment the mandibular vascularity devastated by radiation therapy. Nineteen male Lewis rats were split randomly into three groups: distraction osteogenesis only (n = 5), radiation therapy plus distraction osteogenesis (n = 7), and radiation therapy plus distraction osteogenesis with intraoperative placement of 2 million bone marrow stromal cells (n = 7). A mandibular osteotomy was performed, and an external fixator device was installed. From postoperative days 4 through 12, rats underwent a gradual 5.1-mm distraction followed by a 28-day consolidation period. On postoperative day 40, Microfil was perfused into the vasculature and imaging commenced. Vascular radiomorphometric values were calculated for regions of interest. An analysis of variance with post hoc Tukey or Games-Howell tests was used, dependent on data homogeneity. Stereologic analysis indicated significant remediation in vasculature in the bone marrow stromal cell group compared with the radiation therapy/distraction osteogenesis group. Each of five metrics idicated significant improvements from radiation therapy/distraction osteogenesis to the bone marrow stromal cell group, with no difference between the bone marrow stromal cell group and the distraction osteogenesis group. Bone marrow stromal cells used together with distraction osteogenesis can rejuvenate radiation-impaired vasculogenesis in the mandible, reversing radiation therapy-induced isotropy and creating a robust vascular network. Bone marrow stromal cells may offer clinicians an alternative reconstructive modality that could improve the lifestyle of patients with hypovascular bone.

  15. Memory load modulates graded changes in distracter filtering

    PubMed Central

    Shimi, Andria; Woolrich, Mark W.; Mantini, Dante; Astle, Duncan E.

    2015-01-01

    Our ability to maintain small amounts of information in mind is critical for successful performance on a wide range of tasks. However, it remains unclear exactly how this maintenance is achieved. One possibility is that it is brought about using mechanisms that overlap with those used for attentional control. That is, the same mechanisms that we use to regulate and optimize our sensory processing may be recruited when we maintain information in visual short-term memory (VSTM). We aimed to test this hypothesis by exploring how distracter filtering is modified by concurrent VSTM load. We presented participants with sequences of target items, the order and location of which had to be maintained in VSTM. We also presented distracter items alongside the targets, and these distracters were graded such that they could be either very similar or dissimilar to the targets. We analyzed scalp potentials using a novel multiple regression approach, which enabled us to explore the neural mechanisms by which the participants accommodated these variable distracters on a trial-to-trial basis. Critically, the effect of distracter filtering interacted with VSTM load; the same graded changes in perceptual similarity exerted effects of a different magnitude depending upon how many items participants were already maintaining in VSTM. These data provide compelling evidence that maintaining information in VSTM recruits an overlapping set of attentional control mechanisms that are otherwise used for distracter filtering. PMID:25610387

  16. Neuronal effects of auditory distraction on visual attention

    PubMed Central

    Smucny, Jason; Rojas, Donald C.; Eichman, Lindsay C.; Tregellas, Jason R.

    2013-01-01

    Selective attention in the presence of distraction is a key aspect of healthy cognition. The underlying neurobiological processes, have not, however, been functionally well characterized. In the present study, we used functional magnetic resonance imaging to determine how ecologically relevant distracting noise affects cortical activity in 27 healthy adults during two versions of the visual sustained attention to response task (SART) that differ in difficulty (and thus attentional load). A significant condition (noise or silence) by task (easy or difficult) interaction was observed in several areas, including dorsolateral prefrontal cortex (DLPFC), fusiform gyrus (FG), posterior cingulate (PCC), and pre-supplementary motor area (PreSMA). Post-hoc analyses of interaction effects revealed deactivation of DLPFC, PCC, and PreSMA during distracting noise under conditions of low attentional load, and activation of FG and PCC during distracting noise under conditions of high attentional load. These results suggest that distracting noise may help alert subjects to task goals and reduce demands on cortical resources during tasks of low difficulty and attentional load. Under conditions of higher load, however, additional cognitive resources may be required in the presence of noise. PMID:23291265

  17. Mitigating driver distraction with retrospective and concurrent feedback.

    PubMed

    Donmez, Birsen; Boyle, Linda Ng; Lee, John D

    2008-03-01

    An experiment was conducted to assess the effects of retrospective and combined retrospective and concurrent feedback on driver performance and engagement in distracting activities. A previous study conducted by the authors showed that concurrent (or real time) feedback can help drivers better modulate their distracting activities. However, research also shows that concurrent feedback can pose additional distractions due to the limited time and resources available during driving. Retrospective feedback, which is presented at the end of a trip (i.e., post-drive), can include additional information on safety critical situations during a trip and help the driver learn safe driving habits. A driving simulator study was conducted with 48 participants and 3 conditions: retrospective feedback, combined feedback (both retrospective and concurrent), and no feedback (baseline case). The feedback conditions (retrospective and combined) resulted in faster response to lead vehicle braking events as depicted by shorter accelerator release times. Moreover, combined feedback also resulted in longer glances to the road. The results suggest that both feedback types have potential to improve immediate driving performance and driver engagement in distractions. Combined feedback holds the most promise for mitigating the effects of distraction from in-vehicle information systems.

  18. Does attention capacity moderate the effect of driver distraction in older drivers?

    PubMed

    Cuenen, Ariane; Jongen, Ellen M M; Brijs, Tom; Brijs, Kris; Lutin, Mark; Van Vlierden, Karin; Wets, Geert

    2015-04-01

    With age, a decline in attention capacity may occur and this may impact driving performance especially while distracted. Although the effect of distraction on driving performance of older drivers has been investigated, the moderating effect of attention capacity on driving performance during distraction has not been investigated yet. Therefore, the aim was to investigate whether attention capacity has a moderating effect on older drivers' driving performance during visual distraction (experiment 1) and cognitive distraction (experiment 2). In a fixed-based driving simulator, older drivers completed a driving task without and with visual distraction (experiment 1, N=17, mean age 78 years) or cognitive distraction (experiment 2, N=35, mean age 76 years). Several specific driving measures of varying complexity (i.e., speed, lane keeping, following distance, braking behavior, and crashes) were investigated. In addition to these objective driving measures, subjective measures of workload and driving performance were also included. In experiment 1, crash occurrence increased with visual distraction and was negatively related to attention capacity. In experiment 2, complete stops at stop signs decreased, initiation of braking at pedestrian crossings was later, and crash occurrence increased with cognitive distraction. Interestingly, for a measure of lane keeping (i.e., standard deviation of lateral lane position (SDLP)), effects of both types of distraction were moderated by attention capacity. Despite the decrease of driving performance with distraction, participants estimated their driving performance during distraction as good. These results imply that attention capacity is important for driving. Driver assessment and training programs might therefore focus on attention capacity. Nonetheless, it is crucial to eliminate driver distraction as much as possible given the deterioration of performance on several driving measures in those with low and high attention capacity

  19. Audiovisual distraction for pain relief in paediatric inpatients: A crossover study.

    PubMed

    Oliveira, N C A C; Santos, J L F; Linhares, M B M

    2017-01-01

    Pain is a stressful experience that can have a negative impact on child development. The aim of this crossover study was to examine the efficacy of audiovisual distraction for acute pain relief in paediatric inpatients. The sample comprised 40 inpatients (6-11 years) who underwent painful puncture procedures. The participants were randomized into two groups, and all children received the intervention and served as their own controls. Stress and pain-catastrophizing assessments were initially performed using the Child Stress Scale and Pain Catastrophizing Scale for Children, with the aim of controlling these variables. The pain assessment was performed using a Visual Analog Scale and the Faces Pain Scale-Revised after the painful procedures. Group 1 received audiovisual distraction before and during the puncture procedure, which was performed again without intervention on another day. The procedure was reversed in Group 2. Audiovisual distraction used animated short films. A 2 × 2 × 2 analysis of variance for 2 × 2 crossover study was performed, with a 5% level of statistical significance. The two groups had similar baseline measures of stress and pain catastrophizing. A significant difference was found between periods with and without distraction in both groups, in which scores on both pain scales were lower during distraction compared with no intervention. The sequence of exposure to the distraction intervention in both groups and first versus second painful procedure during which the distraction was performed also significantly influenced the efficacy of the distraction intervention. Audiovisual distraction effectively reduced the intensity of pain perception in paediatric inpatients. The crossover study design provides a better understanding of the power effects of distraction for acute pain management. Audiovisual distraction was a powerful and effective non-pharmacological intervention for pain relief in paediatric inpatients. The effects were

  20. Distracted driving: prevalence, problems, and prevention.

    PubMed

    Overton, Tiffany L; Rives, Terry E; Hecht, Carrie; Shafi, Shahid; Gandhi, Rajesh R

    2015-01-01

    While the number of motor vehicle crashes has declined over the years, crashes resulting from distracted driving are increasing in the United States resulting in significant morbidity and mortality. The national public seems to be aware of the dangers associated with using technology while driving, but continues to engage in this dangerous behaviour, and may be unaware of or underestimate the impact of cell phone use on their own driving performance. Problems associated with distracted driving are not limited to novice or teenage drivers; multifaceted universal prevention efforts aimed at impacting large segments of the population may have the greatest impact. Legislation limiting drivers' cell phone use has had little impact, possibly due to low regulation and enforcement. Behaviour change programmes, improved vehicle safety, and public awareness campaigns have been developed as potential preventive efforts to reduce accidents caused by distracted drivers.

  1. Does Guided Bone Regeneration Prevent Unfavorable Bone Shapes in Distraction Gap?

    PubMed

    Demetoglu, Umut; Alkan, Alper; Kiliç, Erdem; Ozturk, Mustafa; Bilge, Suheyb

    2018-03-01

    Complications related to distraction osteogenesis can cause degradation of newly regenerated bone. Additionally, an unfavorable shape of the regenerated bone at the distraction gap can reduce the quantity of regenerated bone. The aim of the present study was to report on the prevention of unfavorable shapes of regenerated bone using guided bone regeneration during distraction. Bilateral alveolar distraction was performed in 10 beagle dog mandibles. One side of the mandible formed the experimental group and the other side served as the control group. In the experimental group, guided bone regeneration was performed simultaneously with distraction osteogenesis. In the control group, only alveolar distraction was applied. At the end of a 1-week latent period, all mandibles were distracted 10 mm (1 mm/day). After the distraction period, 3 months were allowed for consolidation. After consolidation, all the dogs were euthanized, and the shape of the regenerated bone was determined to be either favorable or unfavorable. Densitometric evaluation and area measurements were performed using computed tomography scans. Statistical evaluation was performed using the independent t test, with a significance level of P < .05. In the experimental group, no unfavorable bone shape developed in the distraction gap, and the new bone had a surface and volume similar to those of the segments. In contrast, in the control group, 4 mandibles had an unfavorable bone shape in the distraction gap and 4 showed favorable bone healing with no defect. The surface area of the regenerating bone in the experimental group was significantly greater than that in the control group. Also, the surface area differed significantly between the experimental and control groups (P < .05). However, the densitometric values did not differ between the 2 groups (P < .05). Concomitant use of guided bone regeneration with distraction osteogenesis could be an optimal method for generating a favorable bone shape

  2. Evaluating Robotic Surgical Skills Performance Under Distractive Environment Using Objective and Subjective Measures.

    PubMed

    Suh, Irene H; LaGrange, Chad A; Oleynikov, Dmitry; Siu, Ka-Chun

    2016-02-01

    Distractions are recognized as a significant factor affecting performance in safety critical domains. Although operating rooms are generally full of distractions, the effect of distractions on robot-assisted surgical (RAS) performance is unclear. Our aim was to investigate the effect of distractions on RAS performance using both objective and subjective measures. Fifteen participants performed a knot-tying task using the da Vinci Surgical System and were exposed to 3 distractions: (1) passive distraction entailed listening to noise with a constant heart rate, (2) active distraction included listening to noise and acknowledging a change of random heart rate from 60 to 120 bpm, and (3) interactive distraction consisted of answering math questions. The objective kinematics of the surgical instrument tips were used to evaluate performance. Electromyography (EMG) of the forearm and hand muscles of the participants were collected. The median EMG frequency (EMG(fmed)) and the EMG envelope (EMG(env)) were analyzed. NASA Task Load Index and Fundamentals of Laparoscopic Surgery score were used to evaluate the subjective performance. One-way repeated analysis of variance was applied to examine the effects of distraction on skills performance. Spearman's correlations were conducted to compare objective and subjective measures. Significant distraction effect was found for all objective kinematics measures (P < .05). There were significant distraction effects for EMG measures (EMG(env), P < .004; EMG(fmed), P = .031). Significant distraction effects were also found for subjective measurements. Distraction impairs surgical skills performance and increases muscle work. Understanding how the surgeons cope with distractions is important in developing surgical education. © The Author(s) 2015.

  3. The Effects of Distraction on Cognitive Task Performance during Toddlerhood

    ERIC Educational Resources Information Center

    Wyss, Nancy M.; Kannass, Kathleen N.; Haden, Catherine A.

    2013-01-01

    We investigated the effects of distraction on attention and task performance during toddlerhood. Thirty toddlers (24- to 26-month-olds) completed different tasks (2 of each: categorization, problem solving, memory, free play) in one of two conditions: No Distraction or Distraction. The results revealed that the distractor had varying effects on…

  4. Tactile Imaging Markers to Characterize Female Pelvic Floor Conditions.

    PubMed

    van Raalte, Heather; Egorov, Vladimir

    2015-08-01

    The Vaginal Tactile Imager (VTI) records pressure patterns from vaginal walls under an applied tissue deformation and during pelvic floor muscle contractions. The objective of this study is to validate tactile imaging and muscle contraction parameters (markers) sensitive to the female pelvic floor conditions. Twenty-two women with normal and prolapse conditions were examined by a vaginal tactile imaging probe. We identified 9 parameters which were sensitive to prolapse conditions ( p < 0.05 for one-way ANOVA and/or p < 0.05 for t -test with correlation factor r from -0.73 to -0.56). The list of parameters includes pressure, pressure gradient and dynamic pressure response during muscle contraction at identified locations. These parameters may be used for biomechanical characterization of female pelvic floor conditions to support an effective management of pelvic floor prolapse.

  5. Optical based tactile shear and normal load sensor

    DOEpatents

    Salisbury, Curt Michael

    2015-06-09

    Various technologies described herein pertain to a tactile sensor that senses normal load and/or shear load. The tactile sensor includes a first layer and an optically transparent layer bonded together. At least a portion of the first layer is made of optically reflective material. The optically transparent layer is made of resilient material (e.g., clear silicone rubber). The tactile sensor includes light emitter/light detector pair(s), which respectively detect either normal load or shear load. Light emitter(s) emit light that traverses through the optically transparent layer and reflects off optically reflective material of the first layer, and light detector(s) detect and measure intensity of reflected light. When a normal load is applied, the optically transparent layer compresses, causing a change in reflected light intensity. When shear load is applied, a boundary between optically reflective material and optically absorptive material is laterally displaced, causing a change in reflected light intensity.

  6. Motion Versus Fixed Distraction of the Joint in the Treatment of Ankle Osteoarthritis

    PubMed Central

    Saltzman, Charles L.; Hillis, Stephen L.; Stolley, Mary P.; Anderson, Donald D.; Amendola, Annunziato

    2012-01-01

    Background: Initial reports have shown the efficacy of fixed distraction for the treatment of ankle osteoarthritis. We hypothesized that allowing ankle motion during distraction would result in significant improvements in outcomes compared with distraction without ankle motion. Methods: We conducted a prospective randomized controlled trial comparing the outcomes for patients with advanced ankle osteoarthritis who were managed with anterior osteophyte removal and either (1) fixed ankle distraction or (2) ankle distraction permitting joint motion. Thirty-six patients were randomized to treatment with either fixed distraction or distraction with motion. The patients were followed for twenty-four months after frame removal. The Ankle Osteoarthritis Scale (AOS) was the main outcome variable. Results: Two years after frame removal, subjects in both groups showed significant improvement compared with the status before treatment (p < 0.02 for both groups). The motion-distraction group had significantly better AOS scores than the fixed-distraction group at twenty-six, fifty-two, and 104 weeks after frame removal (p < 0.01 at each time point). At 104 weeks, the motion-distraction group had an overall mean improvement of 56.6% in the AOS score, whereas the fixed-distraction group had a mean improvement of 22.9% (p < 0.01). Conclusion: Distraction improved the patient-reported outcomes of treatment of ankle osteoarthritis. Adding ankle motion to distraction showed an early and sustained beneficial effect on outcome. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. PMID:22637202

  7. Effects of inter-stimulus interval and intensity on the perceived urgency of tactile patterns.

    PubMed

    White, Timothy L; Krausman, Andrea S

    2015-05-01

    This research examines the feasibility of coding urgency into tactile patterns. Four tactile patterns were presented at either, 12 or 23.5 dB above mean threshold, with an ISI of either 0 (no interval) or 500 msec. Measures included pattern identification and urgency rating on a scale of 1 (least urgent) to 10 (most urgent). Two studies were conducted, a laboratory study and a field study. In the laboratory study, participants received the tactile patterns while seated in front of a computer. For the field study, participants performed dismounted Soldier maneuvers while receiving the tactile patterns. Higher identification rates were found for the 23.5 dB intensity. Patterns presented at the 23.5 dB intensity and no ISI were rated most urgent. No differences in urgency ratings were found for 12 dB based on ISI. Findings support the notion of coding urgency into tactile patterns as a way of augmenting tactile communication. Published by Elsevier Ltd.

  8. Velopharyngeal changes after maxillary distraction in cleft patients using a rigid external distraction device: A retrospective study.

    PubMed

    Taha, Mahasen; Elsheikh, Yasser M

    2016-11-01

     To evaluate early and late velopharyngeal changes in cleft lip and palate (CLP) patients after use of the Rigid External Distractor (RED) device and to correlate these changes to the amount of maxillary advancement.  Thirty Class III CLP patients were included in the study. Maxillary advancement was performed using the RED device in combination with titanium miniplates and screws for anchorage. Lateral cephalograms, nasometer, and nasopharyngoscope records were taken before distraction, immediately after distraction, and 1 year after distraction. A paired t-test was used to detect differences at P < .05.  SNA angle and A point and ANS to Y axis were significantly increased after maxillary distraction (P  =  .0001). Statistically significant increases in nasopharyngeal and oropharyngeal depths, velar angle, and need ratio were also found (P  =  .0001). Nasalance scores showed a significant increase (P  =  .008 for nasal text and .044 for oral text). A significant positive correlation was observed between the amount of maxillary advancement and the increase in nasopharyngeal depth and hypernasality (P  =  .012 and .026, respectively).  Nasopharyngeal function was deteriorated after maxillary advancement in CLP patients. There was a significant positive correlation between the amount of maxillary advancement and the increase in nasopharyngeal depth and hypernasality.

  9. Backward distraction osteogenesis in a patient with severe mandibular micrognathia.

    PubMed

    Mitsukawa, Nobuyuki; Morishita, Tadashi; Saiga, Atsuomi; Akita, Shinsuke; Kubota, Yoshitaka; Satoh, Kaneshige

    2013-09-01

    Maxillary skeletal prognathism can involve severe mandibular micrognathia with marked mandibular retrognathism or hypoplasia. For patients with such a condition, a conventional treatment is mandibular advancement by sagittal split ramus osteotomy (SSRO). This procedure has problems such as insufficient advancement, instability of jaw position, and postoperative relapse. Thus, in recent years, mandibular distraction osteogenesis has been used in some patients. Mandibular distraction has many advantages, but an ideal occlusion is difficult to achieve using this procedure. That is, 3-dimensional control cannot be attained using an internal device that is unidirectional. This report describes a case of severe mandibular micrognathia in a 14-year-old girl treated using backward distraction osteogenesis. This procedure was first reported by Ishii et al (Jpn J Jaw Deform 2004; 14:49) and involves a combination of SSRO and ramus distraction osteogenesis. In the present study, intermaxillary fixation in centric occlusion was performed after osteotomy, and proximal bone segments were distracted in a posterosuperior direction. This procedure is a superior surgical technique that avoids the drawbacks of SSRO and conventional mandibular distraction. However, it applies a large load to the temporomandibular joints and requires thorough management. Thus, careful evaluation needs to be made of the indication for backward distraction osteogenesis.

  10. Nanowire FET Based Neural Element for Robotic Tactile Sensing Skin

    PubMed Central

    Taube Navaraj, William; García Núñez, Carlos; Shakthivel, Dhayalan; Vinciguerra, Vincenzo; Labeau, Fabrice; Gregory, Duncan H.; Dahiya, Ravinder

    2017-01-01

    This paper presents novel Neural Nanowire Field Effect Transistors (υ-NWFETs) based hardware-implementable neural network (HNN) approach for tactile data processing in electronic skin (e-skin). The viability of Si nanowires (NWs) as the active material for υ-NWFETs in HNN is explored through modeling and demonstrated by fabricating the first device. Using υ-NWFETs to realize HNNs is an interesting approach as by printing NWs on large area flexible substrates it will be possible to develop a bendable tactile skin with distributed neural elements (for local data processing, as in biological skin) in the backplane. The modeling and simulation of υ-NWFET based devices show that the overlapping areas between individual gates and the floating gate determines the initial synaptic weights of the neural network - thus validating the working of υ-NWFETs as the building block for HNN. The simulation has been further extended to υ-NWFET based circuits and neuronal computation system and this has been validated by interfacing it with a transparent tactile skin prototype (comprising of 6 × 6 ITO based capacitive tactile sensors array) integrated on the palm of a 3D printed robotic hand. In this regard, a tactile data coding system is presented to detect touch gesture and the direction of touch. Following these simulation studies, a four-gated υ-NWFET is fabricated with Pt/Ti metal stack for gates, source and drain, Ni floating gate, and Al2O3 high-k dielectric layer. The current-voltage characteristics of fabricated υ-NWFET devices confirm the dependence of turn-off voltages on the (synaptic) weight of each gate. The presented υ-NWFET approach is promising for a neuro-robotic tactile sensory system with distributed computing as well as numerous futuristic applications such as prosthetics, and electroceuticals. PMID:28979183

  11. Attention and working memory in elderly: the influence of a distracting environment.

    PubMed

    Rodrigues, Pedro F S; Pandeirada, Josefa N S

    2015-02-01

    The present work investigated the effect of a distracting environment in the performance of attentional and working memory (WM) tasks in elderly participants. To this end, forty elderly performed two attentional tasks (simple reaction time and go/no-go tasks), and three WM tasks (arithmetic, memory for digits and sequences of letters and numbers). Each participant performed the tasks in a distracting and a non-distracting environment, with an interval of 14-21 days between sessions. The results revealed better performance in the attentional tasks when these were done in the non-distracting environment, as compared to when they were done in the distracting environment. Specifically, participants provided more accurate responses, fewer false alarms and omissions when responding in the non-distracting environment than when responding in the distracting environment. Participants were also faster at providing correct responses in the go/no-go task when it was performed in the non-distracting environment. As for the memory tasks, the effect of type of environment was significant only in the memory for digits in a forward direction task. Our data suggest the need to consider the potential damaging consequences of distracting environments when the elderly have to perform tasks that demand their attention. Specific examples of such situations are presented in the discussion (e.g., distracting effect of environment on medical and on psychological evaluations).

  12. Advancement of the anterior maxilla by distraction (case report).

    PubMed

    Karakasis, Dimitri; Hadjipetrou, Loucia

    2004-06-01

    Several techniques of distraction osteogenesis have been applied for the correction of compromised midface in patients with clefts of the lip, alveolus and palate. This article presents a technique of callus distraction applied in a specific case of hypoplasia of a cleft maxilla with the sagittal advancement of the maxilla thus not affecting velopharyngeal function. The decision to apply distraction osteogenesis for advancement of the anterior maxillary segment in cleft patients offers many advantages.

  13. Active Prior Tactile Knowledge Transfer for Learning Tactual Properties of New Objects

    PubMed Central

    Feng, Di

    2018-01-01

    Reusing the tactile knowledge of some previously-explored objects (prior objects) helps us to easily recognize the tactual properties of new objects. In this paper, we enable a robotic arm equipped with multi-modal artificial skin, like humans, to actively transfer the prior tactile exploratory action experiences when it learns the detailed physical properties of new objects. These experiences, or prior tactile knowledge, are built by the feature observations that the robot perceives from multiple sensory modalities, when it applies the pressing, sliding, and static contact movements on objects with different action parameters. We call our method Active Prior Tactile Knowledge Transfer (APTKT), and systematically evaluated its performance by several experiments. Results show that the robot improved the discrimination accuracy by around 10% when it used only one training sample with the feature observations of prior objects. By further incorporating the predictions from the observation models of prior objects as auxiliary features, our method improved the discrimination accuracy by over 20%. The results also show that the proposed method is robust against transferring irrelevant prior tactile knowledge (negative knowledge transfer). PMID:29466300

  14. Maxillary distraction complications in cleft patients.

    PubMed

    Jeblaoui, Y; Morand, B; Brix, M; Lebeau, J; Bettega, G

    2010-06-01

    Cleft lip and palate (CLP) patients often present with a class III malocclusion in connection with a three dimensional maxillary hypoplasia. Twenty-five to 60% of these patients need maxillary advancement. Two solutions are possible: orthognathic surgery and maxillary distraction. The purpose of this study was to evaluate the complications of maxillary distraction in CLP patients. Data was collected from the records of patients treated in our surgery unit between 2000 and 2007. Among the eight patients (four male and four female), five presented with a bilateral CLP, two with a unilateral CLP, and one with a unilateral cleft lip associated to a soft palate cleft. The average age at surgery was 17 years. All underwent a Le Fort I osteotomy with a pterygomaxillary disjunction. An external distractor was used for the first two patients and an internal distractor for the six following patients. After a seven-day latency, activation was implemented at a rate of 1mm twice a day. The average period of consolidation was four months. Maxillary advancement ranged between 7 and 19mm, with an average of 12.6mm. The average follow-up was four years. Complications were noted in seven patients: one intra-operative hemorrhage, one avulsion of a tooth anchored at the pterygoid process during osteotomy, three cases of device dysfunction, two cases of significant pain during activation, one loosening of the orthodontic arch in an external system, two cases of labial ulceration, and one maxillary sinusitis due to migration of a wisdom tooth. Complications of maxillary distraction in CLP patients were very frequent. Most were related to the device and did not interfere with the final result. This must be taken into account when indicating distraction and choosing the device. Two types of complications can occur during distraction: those related to the osteotomy and those related to the device. The complications related to the osteotomy are linked to the cicatricial ground of previous

  15. Salience of Tactile Cues: An Examination of Tactor Actuator and Tactile Cue Characteristics

    DTIC Science & Technology

    2015-08-01

    this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense ...patterns of tactile cue arrays, and some differences due to measurement approach. Implications for future research are discussed. 15. SUBJECT TERMS...results for tactor type, taction, and interaction term for the prediction of forced-choice preference ................................................21

  16. Surface texture can bias tactile form perception.

    PubMed

    Nakatani, Masashi; Howe, Robert D; Tachi, Susumu

    2011-01-01

    The sense of touch is believed to provide a reliable perception of the object's properties; however, our tactile perceptions could be illusory at times. A recently reported tactile illusion shows that a raised form can be perceived as indented when it is surrounded by textured areas. This phenomenon suggests that the form perception can be influenced by the surface textures in its adjacent areas. As perception of texture and that of form have been studied independently of each other, the present study examined whether textures, in addition to the geometric edges, contribute to the tactile form perception. We examined the perception of the flat and raised contact surface (3.0 mm width) with various heights (0.1, 0.2, 0.3 mm), which had either textured or non-textured adjacent areas, under the static, passive and active touch conditions. Our results showed that texture decreased the raised perception of the surface with a small height (0.1 mm) and decreased the flat perception of the physically flat surface under the passive and active touch conditions. We discuss a possible mechanism underlying the effect of the textures on the form perception based on previous neurophysiological findings.

  17. The Effects of Interactive and Passive Distraction on Cold Pressor Pain in Preschool-aged Children

    PubMed Central

    Dahlquist, Lynnda M.; Wohlheiter, Karen

    2011-01-01

    Objective Using a mixed model design, this study examined the effects of interactive versus passive distraction on healthy preschool-aged children’s cold pressor pain tolerance. Methods Sixty-one children aged 3–5 years were randomly assigned to one of the following: interactive distraction, passive distraction, or no distraction control. Participants underwent a baseline cold pressor trial followed by interactive distraction trial, passive distraction trial, or second baseline trial. One or two additional trials followed. Children originally assigned to distraction received the alternate distraction intervention. Controls participated in both interactive and passive distraction trials in counterbalanced order. Results Participants showed significantly higher pain tolerance during both interactive and passive distraction relative to baseline. The two distraction conditions did not differ. Conclusions Interactive and passive video game distraction appear to be effective for preschool-aged children during laboratory pain exposure. Future studies should examine whether more extensive training would enhance effects of interactive video game distraction. PMID:21278378

  18. Muscle response to leg lengthening during distraction osteogenesis.

    PubMed

    Thorey, Fritz; Bruenger, Jens; Windhagen, Henning; Witte, Frank

    2009-04-01

    Continuous lengthening of intact muscles during distraction osteogenesis leads to an increase of sarcomeres and enhances the regeneration of tendons and blood vessels. A high distraction rate leads to an excessive leg and muscle lengthening and might cause damages of muscle fibers with fibrosis, necrosis, and muscle weakness. Complications like muscle contractures or atrophy after postoperative immobilization emphazize the importance of muscles and their function in the clinical outcome. In an animal model of distraction osteogenesis, 18 sheep were operated with an external fixator followed by 4 days latency, 21 days distraction (1.25 mm per day) and 51 days consolidation. The anatomical location (gastrocnemius, peroneus tertius, and first flexor digitorum longus muscle), dimension and occurrence of muscular defects were characterized histologically. The callus formation and leg axis was monitored by weekly X-rays. Additionally, serum creatine kinase was analyzed during a distraction and consolidation period. Significant signs of muscle lesions in all three observed muscles can be found postoperatively, whereas normal callus formation and regular leg axis was observed radiologically. The peroneus tertius and first flexor digitorum longus muscles were found to have significantly more signs of fibrosis, inflammatory, and necrosis. Creatine kinase showed two peaks: 4 and 39 days postoperative as an indication of muscle damage and regeneration. The study implicates that muscle damages should be considered when a long-distance distraction osteogenesis is planned. The surgeon should consider these muscle responses and individually discuss a two-stage treatment or additional muscle tendon releases to minimize the risk of muscle damages.

  19. Maxillary Distraction Osteogenesis in Unilateral Cleft Lip and Palate Patients with Rigid External Distraction System

    PubMed Central

    Alkhouri, Shadi; Waite, Peter D.; Davis, Matthew B.; Lamani, Ejvis; Kau, Chung How

    2017-01-01

    Aim: Distraction osteogenesis (DO) is a treatment option for patients with maxillary hypoplasia secondary to cleft lip and palate (CLP). Purpose: The aim of this study is to present a technique for maxillary DO using Le Fort I osteotomy with rigid external distraction (RED) system. Subjects and Methods: The patient presented in this paper was an Asian female with CLP aged 13 years and 6 months. She presented with severe midfacial deficiency with a Class III dental malocclusion with a negative overjet and concave facial profile. Cone-beam computed tomography images were recorded preoperatively and the operation performed involved a high Le Fort I osteotomy. The appliance fabricated was banded to upper first molars used for anchorage of the RED system. Distraction of the maxilla was initiated after 7-day latency period. Results: Postoperative cephalometric analysis showed maxillary advancement anteriorly and superiorly, the total distraction treatment period was 10 days. The maxillary advancement was 10.5 mm and the SNA angle increased from 67.5° to 77.9°. Furthermore, the ANB angle changed from −9.8° to 1.6° and the occlusion changed from Class III to Class I. The profile of the face changed from concave to convex and a much better esthetic result was achieved. Conclusion: The study suggests RED system to be a reliable alternative procedure for the treatment of midfacial hypoplasia with or without cleft. Furthermore, it minimizes the risk of the surgical procedure and shortens the operating time. PMID:28713737

  20. An Experimental Optical Three-axis Tactile Sensor Featured with Hemispherical Surface

    NASA Astrophysics Data System (ADS)

    Ohka, Masahiro; Kobayashi, Hiroaki; Takata, Jumpei; Mitsuya, Yasunaga

    We are developing an optical three-axis tactile sensor capable of acquiring normal and shearing force to mount on a robotic finger. The tactile sensor is based on the principle of an optical waveguide-type tactile sensor, which is composed of an acrylic hemispherical dome, a light source, an array of rubber sensing elements, and a CCD camera. The sensing element of the silicone rubber comprises one columnar feeler and eight conical feelers. The contact areas of the conical feelers, which maintain contact with the acrylic dome, detect the three-axis force applied to the tip of the sensing element. Normal and shearing forces are then calculated from integration and centroid displacement of the grayscale value derived from the conical feeler's contacts. To evaluate the present tactile sensor, we conducted a series of experiments using an x-z stage, a rotational stage, and a force gauge. Although we discovered that the relationship between the integrated grayscale value and normal force depends on the sensor's latitude on the hemispherical surface, it is easy to modify the sensitivity based on the latitude to make the centroid displacement of the grayscale value proportional to the shearing force. When we examined the repeatability of the present tactile sensor with 1,000 load/unload cycles, the error was 2%.

  1. Bilateral Symmetry of Distortions of Tactile Size Perception.

    PubMed

    Longo, Matthew R; Ghosh, Arko; Yahya, Tasneem

    2015-01-01

    The perceived distance between touches on the limbs is generally bigger for distances oriented across the width of the limb than for distances oriented along the length of the limb. The present study aimed to investigate the coherence of such distortions of tactile size perception across different skin surfaces. We investigated distortions of tactile size perception on the dorsal and palmar surfaces of both the left and right hands as well as the forehead. Participants judged which of two tactile distances felt larger. One distance was aligned with the proximodistal axis (along the body), the other with the mediolateral axis (across the body). Clear distortions were found on all five skin surfaces, with stimuli oriented across the width of the body being perceived as farther apart than those oriented along the length of the body. Consistent with previous results, distortions were smaller on the palmar than on the dorsal hand surface. Distortion on the forehead was intermediate between the dorsal and palmar surfaces. There were clear correlations between distortion on the left and right hands, for both the dorsal and palmar skin surfaces. In contrast, within each hand, there was no significant correlation between the two skin surfaces. Distortion on the forehead was not significantly correlated with that on any of the other skin surfaces. These results provide evidence for bilaterally symmetric representations underlying tactile size perception. © The Author(s) 2015.

  2. Patient-specific Distraction Regimen to Avoid Growth-rod Failure.

    PubMed

    Agarwal, Aakash; Jayaswal, Arvind; Goel, Vijay K; Agarwal, Anand K

    2018-02-15

    A finite element study to establish the relationship between patient's curve flexibility (determined using curve correction under gravity) in juvenile idiopathic scoliosis and the required distraction frequency to avoid growth rod fracture, as a function of time. To perform a parametric analysis using a juvenile scoliotic spine model (single mid-thoracic curve with the apex at the eighth thoracic vertebra) and establish the relationship between curve flexibility (determined using curve correction under gravity) and the distraction interval that allows a higher factor of safety for the growth rods. Previous studies have shown that frequent distraction with smaller magnitude of distractions are less likely to result in rod failure. However there has not been any methodology or a chart provided to apply this knowledge on to the individual patients that undergo the treatment. This study aims to fill in that gap. The parametric study was performed by varying the material properties of the disc, hence altering the axial stiffness of the scoliotic spine model. The stresses on the rod were found to increase with increased axial stiffness of the spine, and this resulted in the increase of required optimal frequency to achieve a factor of safety of two for growth rods. A relationship between the percentage correction in Cobb's angle due to gravity alone, and the required distraction interval for limiting the maximum von Mises stress to 255 MPa on the growth rods was established. The distraction interval required to limit the stresses to the selected nominal value reduces with increase in stiffness of the spine. Furthermore, the appropriate distraction interval reduces for each model as the spine becomes stiffer with time (autofusion). This points to the fact the optimal distraction frequency is a time-dependent variable that must be achieved to keep the maximum von Mises stress under the specified factor of safety. The current study demonstrates the possibility of

  3. Conformational Changes in the Carpus During Finger Traps Distraction

    PubMed Central

    Leventhal, Evan L.; Moore, Douglas C.; Akelman, Edward; Wolfe, Scott W.; Crisco, Joseph J.

    2010-01-01

    Introduction Wrist distraction is a common treatment maneuver used clinically for the reduction of distal radial fractures and mid-carpal dislocations. Wrist distraction is also required during wrist arthroscopy to access the radiocarpal joint and has been used as a test for scapholunate ligament injury. However, the effect of a distraction load on the normal wrist has not been well studied. The purpose of this study was to measure the 3-D conformational changes of the carpal bones in the normal wrist as a result of a static distractive load. Methods The dominant wrists of 14 healthy volunteers were scanned using computed tomography at rest and during application of 98N of distraction. Load was applied using finger traps and volunteers were encouraged to relax their forearm muscles and to allow distraction of the wrist. The motions of the bones in the wrist were tracked between the unloaded and loaded trial using markerless bone registration. The average displacement vector of each bone was calculated relative to the radius as well as the interbone distances for 20 bone-bone interactions. Joint separation was estimated at the radiocarpal, midcarpal and carpal-metacarpal joints in the direction of loading using the radius, lunate, capitate and 3rd metacarpal. Results With loading, the distance between the radius and 3rd metacarpal increased an average of 3.3±3.1mm in the direction of loading. This separation was primarily located in the axial direction at the radiocarpal (1.0±1.0mm) and midcarpal (2.0±1.7mm) joints. There were minimal changes in the transverse direction within the distal row, although the proximal row narrowed by 0.98±0.7mm. Distraction between the radius and scaphoid (2.5±2.2mm) was 2.4 times greater than between the radius and lunate (1.0±1.0mm). Conclusions Carpal distraction has a significant effect on the conformation of the carpus, especially at the radiocarpal and midcarpal joints. In the normal wrist, external traction causes twice as

  4. Conformational changes in the carpus during finger trap distraction.

    PubMed

    Leventhal, Evan L; Moore, Douglas C; Akelman, Edward; Wolfe, Scott W; Crisco, Joseph J

    2010-02-01

    Wrist distraction is a common treatment maneuver used clinically for the reduction of distal radial fractures and midcarpal dislocations. Wrist distraction is also required during wrist arthroscopy to access the radiocarpal joint and has been used as a test for scapholunate ligament injury. However, the effect of a distraction load on the normal wrist has not been well studied. The purpose of this study was to measure the three-dimensional conformational changes of the carpal bones in the normal wrist as a result of a static distractive load. Using computed tomography, the dominant wrists of 14 healthy volunteers were scanned at rest and during application of 98 N of distraction. Load was applied using finger traps, and volunteers were encouraged to relax their forearm muscles and to allow distraction of the wrist. The motions of the bones in the wrist were tracked between the unloaded and loaded trial using markerless bone registration. The average displacement vector of each bone relative to the radius was calculated, as were the interbone distances for 20 bone-bone interactions. Joint separation was estimated at the radiocarpal, midcarpal, and carpometacarpal joints in the direction of loading using the radius, lunate, capitate, and third metacarpal. With loading, the distance between the radius and third metacarpal increased an average of 3.3 mm +/- 3.1 in the direction of loading. This separation was primarily in the axial direction at the radiocarpal (1.0 mm +/- 1.0) and midcarpal (2.0 mm +/- 1.7) joints. There were minimal changes in the transverse direction within the distal row, although the proximal row narrowed by 0.98 mm +/- 0.7. Distraction between the radius and scaphoid (2.5 mm +/- 2.2) was 2.4 times greater than that between the radius and lunate (1.0 mm +/- 1.0). Carpal distraction has a significant (p < .01) effect on the conformation of the carpus, especially at the radiocarpal and midcarpal joints. In the normal wrist, external traction causes

  5. Tactile Imaging Markers to Characterize Female Pelvic Floor Conditions

    PubMed Central

    van Raalte, Heather; Egorov, Vladimir

    2015-01-01

    The Vaginal Tactile Imager (VTI) records pressure patterns from vaginal walls under an applied tissue deformation and during pelvic floor muscle contractions. The objective of this study is to validate tactile imaging and muscle contraction parameters (markers) sensitive to the female pelvic floor conditions. Twenty-two women with normal and prolapse conditions were examined by a vaginal tactile imaging probe. We identified 9 parameters which were sensitive to prolapse conditions (p < 0.05 for one-way ANOVA and/or p < 0.05 for t-test with correlation factor r from −0.73 to −0.56). The list of parameters includes pressure, pressure gradient and dynamic pressure response during muscle contraction at identified locations. These parameters may be used for biomechanical characterization of female pelvic floor conditions to support an effective management of pelvic floor prolapse. PMID:26389014

  6. Maxillary advancement using distraction osteogenesis with intraoral device.

    PubMed

    Takigawa, Yoko; Uematsu, Setsuko; Takada, Kenji

    2010-11-01

    This article describes the surgical orthodontic treatment of maxillary hypoplasia in a patient with cleft lip and palate using maxillary distraction osteogenesis with internal maxillary distractors. Maxillary advancement was performed to correct the retrusive maxillary facial profile and Class III malocclusion. Rotational movement of the distraction segment was made to correct the upper dental midline. Although maxillary advancement was insufficient because of unexpected breakage of the intraoral distractor after completion of the distraction, skeletal traction with a face mask compensated for the shortage. Successful esthetic improvement and posttreatment occlusal stability were achieved with no discernible relapse after 2 years of retention.

  7. Distraction of clinicians by smartphones in hospitals: a concept analysis.

    PubMed

    McBride, Deborah L

    2015-09-01

    To report an analysis of the concept of distraction of clinicians by smartphones and other mobile devices in hospitals. In the healthcare literature, the concept of distraction of clinicians by smartphones and other mobile devices in hospitals has no consistent definition. Concept analysis. Journal articles published from 2003-2014. Rodgers' Evolutionary Concept Analysis Method was used to analyse the concept of distraction of clinicians by smartphones and other mobile devices in hospitals. This analysis led to a definition of distraction of clinicians by smartphones as the interruption of a hospital clinician's primary task by the internally or externally initiated use of their smartphone or other mobile device. There are six attributes of distraction by smartphones and other mobile devices in hospitals. These attributes are: (1) an experience by a clinician; (2) an intrusion into a primary clinical task; (3) discontinuity of the clinical task; (4) externally or internally initiated; (5) situated in a healthcare setting; and (6) mediated by a smartphone or other mobile device. Use of the definition and the defining attributes of distraction of clinicians by smartphones will increase the validity and reliability of future studies. It will be extended to form a classification system of distractions within a framework of clinical practice, which will be used to unify and standardize future research studies. © 2015 John Wiley & Sons Ltd.

  8. Exploring inattention and distraction in the SafetyNet Accident Causation Database.

    PubMed

    Talbot, Rachel; Fagerlind, Helen; Morris, Andrew

    2013-11-01

    Distraction and inattention are considered to be very important and prevalent factors in the causation of road accidents. There have been many recent research studies which have attempted to understand the circumstances under which a driver becomes distracted or inattentive and how distraction/inattention can be prevented. Both factors are thought to have become more important in recent times partly due to the evolution of in-vehicle information and communication technology. This study describes a methodology that was developed to understand when factors such as distraction and inattention may have been contributors to crashes and also describes some of the consequences of distraction and inattention in terms of subsequent driver actions. The study uses data relating to distraction and inattention from the SafetyNet Accident Causation Database. This database was formulated as part of the SafetyNet project to address the lack of representative in-depth accident causation data within the European Union. Data were collected in 6 European countries using 'on-scene' and 'nearly on-scene' crash investigation methodologies. 32% of crashes recorded in the database, involved at least one driver, rider or pedestrian, who was determined to be 'Inattentive' or 'Distracted'. 212 of the drivers were assigned 'Distraction' and 140 drivers were given the code 'Inattention'. It was found that both distraction and inattention often lead to missed observations within the driving task and consequently 'Timing' or 'Direction' become critical events in the aetiology of crashes. In addition, the crash types and outcomes may differ according to the type and nature of the distraction and inattention as determined by the in-depth investigations. The development of accident coding methodology is described in this study as is its evolution into the Driver Reliability and Error Analysis Model (DREAM) version 3.0. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Long-term follow-up of early cleft maxillary distraction.

    PubMed

    Park, Young-Wook; Kwon, Kwang-Jun; Kim, Min-Keun

    2016-12-01

    Most of cleft lip and palate patients have the esthetic and functional problems of midfacial deficiencies due to innate developmental tendency and scar tissues from repeated operations. In these cases, maxillary protraction is required for the harmonious facial esthetics and functional occlusion. A 7-year old boy had been diagnosed as severe maxillary constriction due to unilateral complete cleft lip and palate. The author tried to correct the secondary deformity by early distraction osteogenesis with the aim of avoiding marked psychological impact from peers of elementary school. From 1999 to 2006, repeated treatments, which consisted of Le Fort I osteotomy and face mask distraction, and complementary maxillary protraction using miniplates were performed including orthodontics. But, final facial profile was not satisfactory, which needs compromising surgery. The result of this study suggests that if early distraction treatment is performed before facial skeletal growth is completed, an orthognathic surgery or additional distraction may be needed later. Maxillofacial plastic and reconstructive surgeons should notify this point when they plan early distraction treatment for cleft maxillary deformity.

  10. Carpal tunnel volume changes of the wrist under distraction.

    PubMed

    Cho, M S; Means, K R; Shrout, J A; Segalman, K A

    2008-10-01

    This study attempts to determine changes in carpal canal volume with distraction across the wrist. Uniform longitudinal distraction was maintained with two external fixators on the radial and ulnar aspects of the forearm axis of five cadaver specimens. After CT scanning, volume determinations were made at 5 mm increments beginning at the lunocapitate joint to a point 1.5 cm distal to the middle finger carpometacarpal joint. There was a statistically significant decrease of the mean total carpal canal volume from 0 to 4.54 kg of distraction, with no statistically significant decrease from 0 to 2.27 kg or 2.27 to 4.54 kg. The largest decrease occurred at 15 and 20 mm distal to the proximal edge of the transverse carpal ligament corresponding to the level of the hamate hook. Reduction in mean carpal canal volume was 10.2% and 7.5% at these distances, respectively, from 0 to 4.54 kg of distraction. Progressive distraction across the wrist causes a decrease in total carpal canal volume.

  11. Braille and Tactile Graphics: Youths with Visual Impairments Share Their Experiences

    ERIC Educational Resources Information Center

    Rosenblum, L. Penny; Herzberg, Tina S.

    2015-01-01

    Introduction: Data were collected from youths with visual impairment about their experiences with tactile graphics and braille materials used in mathematics and science classes. Methods: Youths answered questions and explored four tactile graphics made using different production methods. They located specific information on each graphic and shared…

  12. Use of early tactile stimulation in rehabilitation of digital nerve injuries.

    PubMed

    Cheng, A S

    2000-01-01

    Digital nerves are the most frequently injured peripheral nerve. To improve the recovery of functional sensibility of digital nerve injuries, a prospective randomized controlled study was conducted to see the effect of using early tactile stimulation in rehabilitation of digital nerve injuries. Two specific tactile stimulators were made and prescribed for patients with digital nerve-injury. Twenty-four participants with 32 digital nerve injuries received the prescribed tactile stimulators (experimental group), and another 25 participants with 33 digital nerve injuries received only routine conventional therapy (control group). A significant difference (p < .05) was seen in the experimental group, although there were some variations between the different classes of associated injuries, with least benefit observed in the combined nerve, tendon, and bone injury class. Use of early tactile stimulation as described in this study can be considered an effective way to improve both quality and quantity of recovery of functional sensibility in digital nerve injuries without combined nerve, tendon, and bone injuries.

  13. Tactile agnosia. Casuistic evidence and theoretical remarks on modality-specific meaning representations and sensorimotor integration.

    PubMed

    Platz, T

    1996-10-01

    Somaesthetic, motor and cognitive functions were studied in a man with impaired tactile object-recognition (TOR) in his left hand due to a right parietal convexity meningeoma which had been surgically removed. Primary motor and somatosensory functions were not impaired, and discriminative abilities for various tactile aspects and cognitive skills were preserved. Nevertheless, the patient could often not appreciate the object's nature or significance when it was placed in his left hand and was unable to name or to describe or demonstrate the use of these objects. Therefore, he can be regarded as an example of associative tactile agnosia. The view is taken and elaborated that defective modality-specific meaning representations account for associative tactile agnosia. These meaning representations are conceptualized as learned unimodal feature-entity relationships which are thought to be defective in tactile agnosia. In line with this hypothesis, tactile feature analysis and cross-modal matching of features were largely preserved in the investigated patient, while combining features to form entities was defective in the tactile domain. The alternative hypothesis of agnosia as deficit of cross-modal association of features was not supported. The presumed distributed functional network responsible for TOR is thought to involve perception of features, object recognition and related tactile motor behaviour interactively. A deficit leading primarily to impaired combining features to form entities can therefore be expected to result in additional minor impairment of related perceptual-motor processes. Unilaterality of the gnostic deficit can be explained by a lateralized organization of the functional network responsible for tactile recognition of objects.

  14. Visual enhancing of tactile perception in the posterior parietal cortex.

    PubMed

    Ro, Tony; Wallace, Ruth; Hagedorn, Judith; Farnè, Alessandro; Pienkos, Elizabeth

    2004-01-01

    The visual modality typically dominates over our other senses. Here we show that after inducing an extreme conflict in the left hand between vision of touch (present) and the feeling of touch (absent), sensitivity to touch increases for several minutes after the conflict. Transcranial magnetic stimulation of the posterior parietal cortex after this conflict not only eliminated the enduring visual enhancement of touch, but also impaired normal tactile perception. This latter finding demonstrates a direct role of the parietal lobe in modulating tactile perception as a result of the conflict between these senses. These results provide evidence for visual-to-tactile perceptual modulation and demonstrate effects of illusory vision of touch on touch perception through a long-lasting modulatory process in the posterior parietal cortex.

  15. Neuronal Effects of Auditory Distraction on Visual Attention

    ERIC Educational Resources Information Center

    Smucny, Jason; Rojas, Donald C.; Eichman, Lindsay C.; Tregellas, Jason R.

    2013-01-01

    Selective attention in the presence of distraction is a key aspect of healthy cognition. The underlying neurobiological processes, have not, however, been functionally well characterized. In the present study, we used functional magnetic resonance imaging to determine how ecologically relevant distracting noise affects cortical activity in 27…

  16. Tactile Perception of Roughness and Hardness to Discriminate Materials by Friction-Induced Vibration

    PubMed Central

    Zhao, Xuezeng

    2017-01-01

    The human fingertip is an exquisitely powerful bio-tactile sensor in perceiving different materials based on various highly-sensitive mechanoreceptors distributed all over the skin. The tactile perception of surface roughness and material hardness can be estimated by skin vibrations generated during a fingertip stroking of a surface instead of being maintained in a static position. Moreover, reciprocating sliding with increasing velocities and pressures are two common behaviors in humans to discriminate different materials, but the question remains as to what the correlation of the sliding velocity and normal load on the tactile perceptions of surface roughness and hardness is for material discrimination. In order to investigate this correlation, a finger-inspired crossed-I beam structure tactile tester has been designed to mimic the anthropic tactile discrimination behaviors. A novel method of characterizing the fast Fourier transform integral (FFT) slope of the vibration acceleration signal generated from fingertip rubbing on surfaces at increasing sliding velocity and normal load, respectively, are defined as kv and kw, and is proposed to discriminate the surface roughness and hardness of different materials. Over eight types of materials were tested, and they proved the capability and advantages of this high tactile-discriminating method. Our study may find applications in investigating humanoid robot perceptual abilities. PMID:29182538

  17. Reading text while driving: understanding drivers' strategic and tactical adaptation to distraction.

    PubMed

    Liang, Yulan; Horrey, William J; Hoffman, Joshua D

    2015-03-01

    In this study, we investigated how drivers adapt secondary-task initiation and time-sharing behavior when faced with fluctuating driving demands. Reading text while driving is particularly detrimental; however, in real-world driving, drivers actively decide when to perform the task. In a test track experiment, participants were free to decide when to read messages while driving along a straight road consisting of an area with increased driving demands (demand zone) followed by an area with low demands. A message was made available shortly before the vehicle entered the demand zone. We manipulated the type of driving demands (baseline, narrow lane, pace clock, combined), message format (no message, paragraph, parsed), and the distance from the demand zone when the message was available (near, far). In all conditions, drivers started reading messages (drivers' first glance to the display) before entering or before leaving the demand zone but tended to wait longer when faced with increased driving demands. While reading messages, drivers looked more or less off road, depending on types of driving demands. For task initiation, drivers avoid transitions from low to high demands; however, they are not discouraged when driving demands are already elevated. Drivers adjust time-sharing behavior according to driving demands while performing secondary tasks. Nonetheless, such adjustment may be less effective when total demands are high. This study helps us to understand a driver's role as an active controller in the context of distracted driving and provides insights for developing distraction interventions. © 2014, Human Factors and Ergonomics Society.

  18. Understanding commercial truck drivers' decision-makin process concerning distracted driving.

    PubMed

    Swedler, David I; Pollack, Keshia M; Gielen, Andrea C

    2015-05-01

    A concurrent mixed methods design was used to explore personal and workplace factors, informed by the Theory of Planned Behavior, that affect truck drivers' decision-making about distracted driving on the job. Qualitative data were collected via semi-structured interviews with experts in truck safety and distracted driving, and quantitative data were collected via online survey of truck drivers in the United States. Findings from the interviews illustrated how drivers perceived distractions and the importance of supervisors enforcing organizational distracted driving policies. Survey results found that behavioral intentions were most important in regards to texting and crash and near-crash outcomes, while perceived norms from management best described the correlation between dispatch device use and negative crash-related outcomes. By using a mixed methods design, rather than two separate studies, these findings revealed nuanced differences into the influence of supervisors on distracted driving. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Anterior Segmental Distraction Osteogenesis in the Hypoplastic Cleft Maxilla

    PubMed Central

    Rao (Janardhan), Sruthi; Kotrashetti, S. M.; Lingaraj, J. B.; Pinto, P. X.; Keluskar, K. M.; Jain, Siddharth; Sone, Piyush; Rao, Santhosh

    2013-01-01

    Orthognathic surgery and distraction osteogenesis play a prime role in the correction of maxillary hypoplasia in patients with cleft lip and palate (CLP). Advancement of the anterior maxilla alone without interfering with the velopharyngeal sphincter may be advantageous in cleft patients, who more commonly have speech deficits and dental crowding. We present a case series of anterior maxillary segmental distraction for maxillary hypoplasia in 5 CLP patients with a one-year follow-up. A custom-made tooth-borne distraction device with a hyrax screw positioned anteroposteriorly was used. The evaluation comprised of hard and soft tissue analysis and speech assessment. A stable occlusion with positive overjet and correction of dental-crowding without extraction was achieved at one year post-distraction. Facial profile and lip support improved. There was no deterioration in speech. PMID:23984033

  20. The role of tactile feedback in grip force during laparoscopic training tasks.

    PubMed

    Wottawa, Christopher R; Cohen, Jeremiah R; Fan, Richard E; Bisley, James W; Culjat, Martin O; Grundfest, Warren S; Dutson, Erik P

    2013-04-01

    Laparoscopic minimally invasive surgery has revolutionized surgical care by reducing trauma to the patient, thereby decreasing the need for medication and shortening recovery times. During open procedures, surgeons can directly feel tissue characteristics. However, in laparoscopic surgery, tactile feedback during grip is attenuated and limited to the resistance felt in the tool handle. Excessive grip force during laparoscopic surgery can lead to tissue damage. Providing additional supplementary tactile feedback may allow subjects to have better control of grip force and identification of tissue characteristics, potentially decreasing the learning curve associated with complex minimally invasive techniques. A tactile feedback system has been developed and integrated into a modified laparoscopic grasper that allows forces applied at the grasper tips to be felt by the surgeon's hands. In this study, 15 subjects (11 novices, 4 experts) were asked to perform single-handed peg transfers using these laparoscopic graspers in three trials (feedback OFF, ON, OFF). Peak and average grip forces (newtons) during each grip event were measured and compared using a Wilcoxon ranked test in which each subject served as his or her own control. After activating the tactile feedback system, the novice subject population showed significant decreases in grip force (p < 0.003). When the system was deactivated for the third trial, there were significant increases in grip force (p < 0.003). Expert subjects showed no significant improvements with the addition of tactile feedback (p > 0.05 in all cases). Supplementary tactile feedback helped novice subjects reduce grip force during the laparoscopic training task but did not offer improvements for the four expert subjects. This indicates that tactile feedback may be beneficial for laparoscopic training but has limited long-term use in the nonrobotic setting.

  1. Microstructured graphene arrays for highly sensitive flexible tactile sensors.

    PubMed

    Zhu, Bowen; Niu, Zhiqiang; Wang, Hong; Leow, Wan Ru; Wang, Hua; Li, Yuangang; Zheng, Liyan; Wei, Jun; Huo, Fengwei; Chen, Xiaodong

    2014-09-24

    A highly sensitive tactile sensor is devised by applying microstructured graphene arrays as sensitive layers. The combination of graphene and anisotropic microstructures endows this sensor with an ultra-high sensitivity of -5.53 kPa(-1) , an ultra-fast response time of only 0.2 ms, as well as good reliability, rendering it promising for the application of tactile sensing in artificial skin and human-machine interface. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Transantral distraction devices in correction of severe maxillary deformity in cleft patients.

    PubMed

    Shokirov, Shokhruh; Wangerin, Konrad

    2011-01-01

    Maxillary advancement by Le Fort I osteotomy in cleft patients has an average relapse of about 40-60 percent. With extraoral distraction devices it is possible to obtain an almost unlimited advancement of the upper jaw. Due to the social problems the retention period is normally reduced to some monthes. A relapse of 10-25 % can be seen in these cases. Le Fort I internal distraction osteogenesis offers an alternative to one-step orthognathic advancement, with advantages of gradual lengthening through scar and earlier treatment in growing patients. The objective of this study was to present our experience in the treatment of maxillary deficiency in cleft patients using transantral internal distraction devices. The distraction procedure was successfully accomplished in seventeen patients. For all the seventeen patients maxillary distraction device designed by Konrad Wangerin was used. The distraction distances were 8 to 24 mm. Preoperative, postoperative, and follow-up (12 and 24 months) lateral cephalogram measurements were compared including angular and linear changes. A good new bone was found that was formed in distraction pitch between lines of osteotomy. After distraction of median facial zone, occlusion and profile of soft tissues were considerably improved. All patients after postoperative time required final orthodontic treatment and their final occlusal relationships were satisfactory. The transantral distraction device is a new option for the treatment of severe maxillary hypoplasia in cleft patients.

  3. Improved tactile resonance sensor for robotic assisted surgery

    NASA Astrophysics Data System (ADS)

    Oliva Uribe, David; Schoukens, Johan; Stroop, Ralf

    2018-01-01

    This paper presents an improved tactile sensor using a piezoelectric bimorph able to differentiate soft materials with similar mechanical characteristics. The final aim is to develop intelligent surgical tools for brain tumour resection using integrated sensors in order to improve tissue tumour delineation and tissue differentiation. The bimorph sensor is driven using a random phase multisine and the properties of contact between the sensor's tip and a certain load are evaluated by means of the evaluation of the nonparametric FRF. An analysis of the nonlinear contributions is presented to show that the use of a linear model is feasible for the measurement conditions. A series of gelatine phantoms were tested. The tactile sensor is able to identify minimal differences in the consistency of the measured samples considering viscoelastic behaviour. A variance analysis was performed to evaluate the reliability of the sensors and to identify possible error sources due to inconsistencies in the preparation method of the phantoms. The results of the variance analysis are discussed showing that ability of the proposed tactile sensor to perform high quality measurements.

  4. Tactile sensitivity of gloved hands in the cold operation.

    PubMed

    Geng, Q; Kuklane, K; Holmér, I

    1997-11-01

    In this study, tactile sensitivity of gloved hand in the cold operation has been investigated. The relations among physical properties of protective gloves and hand tactile sensitivity and cold protection were also analysed both objectively and subjectively. Subjects with various gloves participated in the experimental study during cold exposure at different ambient temperatures of -12 degrees C and -25 degrees C. Tactual performance was measured using an identification task with various sizes of objects over the percentage of misjudgment. Forearm, hand and finger skin temperatures were also recorded throughout. The experimental data were analysed using analysis of variance (ANOVA) model and the Tukey's multiple range test. The results obtained indicated that the tactual performance was affected both by gloves and by hands/fingers cooling. Effect of object size on the tactile discrimination was significant and the misjudgment increased when similar sizes of objects were identified, especially at -25 degrees C.

  5. The use of internal maxillary distraction for maxillary hypoplasia: a preliminary report.

    PubMed

    Van Sickels, Joseph E; Madsen, Mathew J; Cunningham, Larry L; Bird, Douglas

    2006-12-01

    Distraction osteogenesis is a useful alternative to advance the maxilla in complicated cases of maxillary hypoplasia. The purpose of this article is to review the workup, experience, and preliminary results with the use of internal distraction osteogenesis for maxillary hypoplasia at one teaching institution. Over a 5-year period, more than 300 patients with craniofacial and dentofacial defects have undergone oral and maxillofacial surgery at our center to correct their skeletal discrepancies. Of these, 10 have had maxillary distraction osteogenesis done with internal distractors. Follow-up of 6 months or more was available for 8 patients. Stereolithographic models were used to bend distractors prior to surgery in 6 patients. Latency prior to the start of distraction was 3 to 7 days and varied with the age of the patient. Distraction occurred at approximately 1 mm per day with an average distraction length of 8.5 mm (range, 6-10 mm). Excellent occlusal results were obtained in 5 patients. Major complications including nonunion and failure to achieve acceptable occlusal results were observed in 3 patients. Minor complications including pain and loosening of the distracter devices were observed in 2 patients, but did not appear to affect the esthetic and functional results. Distraction osteogenesis is a useful alternative to traditional orthognathic surgery to treat maxillary hypoplasia. Internal distractions are attractive to patients, but are more difficult to place and can cause discomfort to patients when trying to achieve an ideal primary vector of distraction. Stereolithographic models can help with placement of the device. Changes in design of distractors may help with patient discomfort.

  6. Homework Distraction Scale: Confirming the Factor Structure With Middle School Students

    ERIC Educational Resources Information Center

    Xu, Jianzhong; Fan, Xitao; Du, Jianxia

    2016-01-01

    The goal of the current investigation was to evaluate psychometric properties of the Homework Distraction Scale (HDS) using 796 middle school students. Results from confirmatory factor analyses (CFAs) supported the presence of two distinct yet related subscales for the HDS: Conventional Distraction and Tech-Related Distraction. Results of…

  7. Cognitive Distraction and African American Women's Endorsement of Gender Role Stereotypes

    ERIC Educational Resources Information Center

    Smith, Kalynda; Craig-Henderson, Kellina

    2010-01-01

    The present study investigated the effect of cognitive distraction on the endorsement of gender role stereotypes in one sample of African American female participants. Participants' awareness and endorsement of gender role stereotypes for male and females was assessed. Following random assignment to distraction or no distraction conditions, they…

  8. Tactile perceptual learning: learning curves and transfer to the contralateral finger.

    PubMed

    Kaas, Amanda L; van de Ven, Vincent; Reithler, Joel; Goebel, Rainer

    2013-02-01

    Tactile perceptual learning has been shown to improve performance on tactile tasks, but there is no agreement about the extent of transfer to untrained skin locations. The lack of such transfer is often seen as a behavioral index of the contribution of early somatosensory brain regions. Moreover, the time course of improvements has never been described explicitly. Sixteen subjects were trained on the Ludvigh task (a tactile vernier task) on four subsequent days. On the fifth day, transfer of learning to the non-trained contralateral hand was tested. In five subjects, we explored to what extent training effects were retained approximately 1.5 years after the final training session, expecting to find long-term retention of learning effects after training. Results showed that tactile perceptual learning mainly occurred offline, between sessions. Training effects did not transfer initially, but became fully available to the untrained contralateral hand after a few additional training runs. After 1.5 years, training effects were not fully washed out and could be recuperated within a single training session. Interpreted in the light of theories of visual perceptual learning, these results suggest that tactile perceptual learning is not fundamentally different from visual perceptual learning, but might proceed at a slower pace due to procedural and task differences, thus explaining the apparent divergence in the amount of transfer and long-term retention.

  9. The tactile movement aftereffect.

    PubMed

    Hollins, M; Favorov, O

    1994-01-01

    The existence of a tactile movement aftereffect was established in a series of experiments on the palmar surface of the hand and fingers of psychophysical observers. During adaptation, observers cupped their hand around a moving drum for up to 3 min; following this period of stimulation, they typically reported an aftereffect consisting of movement sensations located on and deep to the skin, and lasting for up to 1 min. Preliminary experiments comparing a number of stimulus materials mounted on the drum demonstrated that a surface approximating a low-spatial-frequency square wave, with a smooth microtexture, was especially effective at inducing the aftereffect; this adapting stimulus was therefore used throughout the two main experiments. In Experiment 1, the vividness of the aftereffect produced by 2 min of adaptation was determined under three test conditions: with the hand (1) remaining on the now stationary drum; (2) in contact with a soft, textured surface; or (3) suspended in air. Subjects' free magnitude estimates of the peak vividness of the aftereffect were not significantly different across conditions; each subject experienced the aftereffect at least once under each condition. Thus the tactile movement aftereffect does not seem to depend critically on the ponditions of stimulation that obtain while it is being experienced. In Experiment 2, the vividness and duration of the aftereffect were measured as a function of the duration of the adapting stimulus. Both measures increased steadily over the range of durations explored (30-180 sec). In its dependence on adapting duration, the aftereffect resembles the waterfall illusion in vision. An explanation for the tactile movement aftereffect is proposed, based on the model of cortical dynamics of Whitsel et al. (1989, 1991). With assumed modest variation of one parameter across individuals, this application of the model is able to account both for the data of the majority of subjects, who experienced the

  10. Perpendicular serial maxillary distraction osteogenesis in cleft lip and palate patients

    PubMed Central

    Ylikontiola, Leena P.; Sándor, George K.; Harila, Virpi

    2015-01-01

    Background: Cleft lip and palate patients often have a retruded maxilla with a severely narrowed deficient maxillary arch. This report aims to describe the management of severe maxillary retrusion and constriction in cleft lip and palate patients using distraction osteogenesis applied in serial sequence in two directions perpendicular to each other. Materials and Methods: Two adult male cleft lip and palate patients were treated with maxillary distraction osteogenesis in two stages. In the first stage, surgically assisted rapid palatal expansion with a tooth-borne device was performed to significantly expand the maxillary arch in the transverse dimension. After the teeth were orthodontically aligned, the horizontal distraction of the maxilla was made by two internal maxillary distraction devices. Results: In the first patient, the maxilla was initially widened by 11 mm and then distracted forward by 20 mm. Despite the breakage of the shaft of one of the two distractors at the end of distraction, a satisfactory occlusion was found at the time of distractor device removal. The maxillary position has remained stable through 8 years of follow-up. In the second patient, the palate was widened by 14 mm and the maxilla was distracted forward by 22 mm. The maxillary position has remained stable through 3 years of follow-up. Conclusion: Sequential serial distraction of maxilla in two planes perpendicular to each other is a safe and stable approach for the treatment of cleft lip and palate patients with severe transverse and anteroposterior discrepancies. PMID:26981462

  11. Perpendicular serial maxillary distraction osteogenesis in cleft lip and palate patients.

    PubMed

    Ylikontiola, Leena P; Sándor, George K; Harila, Virpi

    2015-01-01

    Cleft lip and palate patients often have a retruded maxilla with a severely narrowed deficient maxillary arch. This report aims to describe the management of severe maxillary retrusion and constriction in cleft lip and palate patients using distraction osteogenesis applied in serial sequence in two directions perpendicular to each other. Two adult male cleft lip and palate patients were treated with maxillary distraction osteogenesis in two stages. In the first stage, surgically assisted rapid palatal expansion with a tooth-borne device was performed to significantly expand the maxillary arch in the transverse dimension. After the teeth were orthodontically aligned, the horizontal distraction of the maxilla was made by two internal maxillary distraction devices. In the first patient, the maxilla was initially widened by 11 mm and then distracted forward by 20 mm. Despite the breakage of the shaft of one of the two distractors at the end of distraction, a satisfactory occlusion was found at the time of distractor device removal. The maxillary position has remained stable through 8 years of follow-up. In the second patient, the palate was widened by 14 mm and the maxilla was distracted forward by 22 mm. The maxillary position has remained stable through 3 years of follow-up. Sequential serial distraction of maxilla in two planes perpendicular to each other is a safe and stable approach for the treatment of cleft lip and palate patients with severe transverse and anteroposterior discrepancies.

  12. Pure Amorphagnosia without Tactile Object Agnosia.

    PubMed

    Kubota, Shinichirou; Yamada, Mai; Satoh, Hideyo; Satoh, Akira; Tsujihata, Mitsuhiro

    2017-01-01

    A 54-year-old female showed amorphagnosia without ahylognosia and tactile agnosia 40 days after the onset of right cerebral infarction. Her basic somatosensory functions were normal. The appreciation of substance qualities (hylognosia) was preserved, but the patient's inability to recognize the size and shape (morphagnosia) was confined to 2- and 3-dimensional shapes (amorphagnosia) in the left hand. However, the patient's ability to recognize real daily objects was well preserved. Brain MRI after admission showed ischemic lesions confined to the right pre- and postcentral gyri and the medial frontal cortex on DWI and FLAIR images. An analysis of SPECT images revealed that the most decreased areas were localized to the pre- and postcentral gyri, superior and inferior parietal lobules, supramarginal gyrus, and angular gyrus. Considering the previous reported cases, the responsible lesion for the impaired perception of hylognosia and morphagnosia may not necessarily be confined to the right hemisphere. To date, 5 reports (6 cases) of tactile agnosia have been published; 4 cases presented with both ahylognosia and amorphagnosia, while 1 presented with only amorphagnosia, and another showed amorphagnosia and mild ahylognosia. Our case is the first to present with only amorphagnosia without tactile agnosia. The mechanism for the well-preserved recognition of real objects may depend on the preserved hylognosia. Of note, there have been no reports showing only ahylognosia without amorphagnosia. Further studies are necessary to clarify whether or not patients with preserved hylognosia or morphagnosia retain the ability to perceive real objects.

  13. Generalization of a tactile stimulus in horses.

    PubMed Central

    Dougherty, D M; Lewis, P

    1993-01-01

    Using horses, we investigated the control of operant behavior by a tactile stimulus (the training stimulus) and the generalization of behavior to six other similar test stimuli. In a stall, the experimenters mounted a response panel in the doorway. Located on this panel were a response lever and a grain dispenser. The experimenters secured a tactile-stimulus belt to the horse's back. The stimulus belt was constructed by mounting seven solenoids along a piece of burlap in a manner that allowed each to provide the delivery of a tactile stimulus, a repetitive light tapping, at different locations (spaced 10.0 cm apart) along the horse's back. Two preliminary steps were necessary before generalization testing: training a measurable response (lip pressing) and training on several reinforcement schedules in the presence of a training stimulus (tapping by one of the solenoids). We then gave each horse two generalization test sessions. Results indicated that the horses' behavior was effectively controlled by the training stimulus. Horses made the greatest number of responses to the training stimulus, and the tendency to respond to the other test stimuli diminished as the stimuli became farther away from the training stimulus. These findings are discussed in the context of behavioral principles and their relevance to the training of horses. PMID:8315368

  14. Generalization of a tactile stimulus in horses.

    PubMed

    Dougherty, D M; Lewis, P

    1993-05-01

    Using horses, we investigated the control of operant behavior by a tactile stimulus (the training stimulus) and the generalization of behavior to six other similar test stimuli. In a stall, the experimenters mounted a response panel in the doorway. Located on this panel were a response lever and a grain dispenser. The experimenters secured a tactile-stimulus belt to the horse's back. The stimulus belt was constructed by mounting seven solenoids along a piece of burlap in a manner that allowed each to provide the delivery of a tactile stimulus, a repetitive light tapping, at different locations (spaced 10.0 cm apart) along the horse's back. Two preliminary steps were necessary before generalization testing: training a measurable response (lip pressing) and training on several reinforcement schedules in the presence of a training stimulus (tapping by one of the solenoids). We then gave each horse two generalization test sessions. Results indicated that the horses' behavior was effectively controlled by the training stimulus. Horses made the greatest number of responses to the training stimulus, and the tendency to respond to the other test stimuli diminished as the stimuli became farther away from the training stimulus. These findings are discussed in the context of behavioral principles and their relevance to the training of horses.

  15. Impact of Distracted Driving on Safety and Traffic Flow

    PubMed Central

    Stavrinos, Despina; Jones, Jennifer L.; Garner, Annie A.; Griffin, Russell; Franklin, Crystal A.; Ball, David; Welburn, Sharon C.; Ball, Karlene K.; Sisiopiku, Virginia P.; Fine, Philip R.

    2015-01-01

    Studies have documented a link between distracted driving and diminished safety; however, an association between distracted driving and traffic congestion has not been investigated in depth. The present study examined the behavior of teens and young adults operating a driving simulator while engaged in various distractions (i.e., cell phone, texting, and undistracted) and driving conditions (i.e., free flow, stable flow, and oversaturation). Seventy five participants 16 to 25 years of age (split into 2 groups: novice drivers and young adults) drove a STISIM simulator three times, each time with one of three randomly presented distractions. Each drive was designed to represent daytime scenery on a 4 lane divided roadway and included three equal roadway portions representing Levels of Service (LOS) A, C, and E as defined in the 2000 Highway Capacity Manual. Participants also completed questionnaires documenting demographics and driving history. Both safety and traffic flow related driving outcomes were considered. A Repeated Measures Multivariate Analysis of Variance was employed to analyze continuous outcome variables and a Generalized Estimate Equation (GEE) poisson model was used to analyze count variables. Results revealed that, in general more lane deviations and crashes occurred during texting. Distraction (in most cases, text messaging) had a significantly negative impact on traffic flow, such that participants exhibited greater fluctuation in speed, changed lanes significantly fewer times, and took longer to complete the scenario. In turn, more simulated vehicles passed the participant drivers while they were texting or talking on a cell phone than while undistracted. The results indicate that distracted driving, particularly texting, may lead to reduced safety and traffic flow, thus having a negative impact on traffic operations. No significant differences were detected between age groups, suggesting that all drivers, regardless of age, may drive in a manner

  16. Impact of distracted driving on safety and traffic flow.

    PubMed

    Stavrinos, Despina; Jones, Jennifer L; Garner, Annie A; Griffin, Russell; Franklin, Crystal A; Ball, David; Welburn, Sharon C; Ball, Karlene K; Sisiopiku, Virginia P; Fine, Philip R

    2013-12-01

    Studies have documented a link between distracted driving and diminished safety; however, an association between distracted driving and traffic congestion has not been investigated in depth. The present study examined the behavior of teens and young adults operating a driving simulator while engaged in various distractions (i.e., cell phone, texting, and undistracted) and driving conditions (i.e., free flow, stable flow, and oversaturation). Seventy five participants 16-25 years of age (split into 2 groups: novice drivers and young adults) drove a STISIM simulator three times, each time with one of three randomly presented distractions. Each drive was designed to represent daytime scenery on a 4 lane divided roadway and included three equal roadway portions representing Levels of Service (LOS) A, C, and E as defined in the 2000 Highway Capacity Manual. Participants also completed questionnaires documenting demographics and driving history. Both safety and traffic flow related driving outcomes were considered. A Repeated Measures Multivariate Analysis of Variance was employed to analyze continuous outcome variables and a Generalized Estimate Equation (GEE) Poisson model was used to analyze count variables. Results revealed that, in general more lane deviations and crashes occurred during texting. Distraction (in most cases, text messaging) had a significantly negative impact on traffic flow, such that participants exhibited greater fluctuation in speed, changed lanes significantly fewer times, and took longer to complete the scenario. In turn, more simulated vehicles passed the participant drivers while they were texting or talking on a cell phone than while undistracted. The results indicate that distracted driving, particularly texting, may lead to reduced safety and traffic flow, thus having a negative impact on traffic operations. No significant differences were detected between age groups, suggesting that all drivers, regardless of age, may drive in a manner

  17. Maxillary-driven simultaneous maxillo-mandibular distraction for hemifacial microsomia.

    PubMed

    Nakajima, Hideo; Sakamoto, Yoshiaki; Tamada, Ikkei; Ogata, Hisao; Kishi, Kazuo; Sakamoto, Teruo

    2011-12-01

    We treat hemifacial microsomia with a combination of surgery and orthodontic treatment during the growth period, resulting in early improvement in facial asymmetry and the induction of normal growth. We previously used gradual distraction of the mandibular ramus for Pruzansky's type II classification (Pruzansky, 1969). In type II cases, the maxilla should also be treated actively as, using this technique, improvement of the occlusal plane is difficult to achieve, resulting in a cross bite and difficulties in post-operative orthodontic treatment-especially in older patients. Morphologically, the mandibular angle region of the operative side is flat, and the angle of the mouth remains elevated. We performed mandibular-driven simultaneous maxillo-mandibular distraction while the occlusion was maintained using intermaxillary anchorage. However, mandibular-driven distraction tended to elongate the face because the mandible only elongated downwards and the mandibular ramus did not reach the glenoid. Furthermore, external distraction devices produce significant distress for patients until removal of the device and cause scars on the face. We developed a new internal distraction device with a variable angle and performed maxillary-driven simultaneous maxillo-mandibular distraction using this device. The result was morphologically satisfactory and solved the above problems. Because the patient was in the growth period, careful follow-up and induction to normal growth were important while the inferior growth of the affected side was monitored. Copyright © 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Experiences in Performing Posterior Calvarial Distraction.

    PubMed

    McMillan, Kevin; Lloyd, Mark; Evans, Martin; White, Nicholas; Nishikawa, Hiroshi; Rodrigues, Desiderio; Sharp, Melanie; Noons, Pete; Solanki, Guirish; Dover, Stephen

    2017-05-01

    The use of posterior calvarial distraction (PCD) for the management of craniosynostosis is well recognized. The advantages of using this technique include increased cranial volume, decreased intracranial pressure, relief of posterior fossa crowding, improved cerebrospinal fluid (CSF) circulation at the cranio-cervical junction with cessation, and possible resolution of syrinx.The authors retrospectively review their first 50 patients who have undergone PCD under the senior author's care in our unit.The demographics, diagnoses, intraoperative approach with techniques in distractor placement and outcomes of each patient were obtained through an electronic craniofacial database and written patient records. Analysis of complication rates (bleeding, distraction problems, CSF leaks, and infection) was included.A total of 31 boys and 19 girls underwent the procedure between October 2006 and September 2015 with a median age was 17.7 months (range 4 months to 19 years). Of those 50 children, 34 of the cohort were proven to be syndromic by genetic testing.The median length of inpatient stay was 9.4 days (range 3-43 days). Average distraction distance was 24 mm.Complications including CSF leaks, bleeding, distractor problems, and severe complications (recorded in 3 patients) are discussed. Our overall complication rate was 50%.Favorable outcomes included resolution of Chiari, syrinx, and raised intracranial pressure in the majority of patients where distraction was successful.The authors recommend that PCD should be considered the primary treatment for increasing calvarial volume. The authors discuss our experiences and technical innovations over the past decade.

  19. Some Effects of Distractions in Nonverbal Mathematical Problems

    ERIC Educational Resources Information Center

    Bana, J. P.; Nelson, D.

    1977-01-01

    The central purpose of this study was to investigate the effects of distractions in nonverbal problems on the problem solving behavior and performance of young children (grades 1-3) in 6 schools (N=360). Results indicated 66 percent of the subjects were distracted by irrelevant spatial-numerical or color attribute uses. (JC)

  20. Left hand tactile agnosia after posterior callosal lesion.

    PubMed

    Balsamo, Maddalena; Trojano, Luigi; Giamundo, Arcangelo; Grossi, Dario

    2008-09-01

    We report a patient with a hemorrhagic lesion encroaching upon the posterior third of the corpus callosum but sparing the splenium. She showed marked difficulties in recognizing objects and shapes perceived through her left hand, while she could appreciate elementary sensorial features of items tactually presented to the same hand flawlessly. This picture, corresponding to classical descriptions of unilateral associative tactile agnosia, was associated with finger agnosia of the left hand. This very unusual case report can be interpreted as an instance of disconnection syndrome, and allows a discussion of mechanisms involved in tactile object recognition.

  1. Refreshable tactile displays based on bistable electroactive polymer

    NASA Astrophysics Data System (ADS)

    Niu, Xiaofan; Brochu, Paul; Salazar, Brandon; Pei, Qibing

    2011-04-01

    Refreshable tactile displays can significantly improve the education of blind children and the quality of life of people with severe vision impairment. A number of actuator technologies have been investigated. Bistable Electroactive Polymer (BSEP) appears to be well suited for this application. The BSEP exhibits a bistable electrically actuated strain as large as 335%. We present improved refreshable tactile display devices fabricated on thin plastic sheets. Stacked BSEP films were employed to meet the requirements in raised dot height and supporting force. The bistable nature of the actuation reduces the power consumption and simplifies the device operation.

  2. Effect of tactile vibration on annoyance to synthesized propfan noise

    NASA Technical Reports Server (NTRS)

    Clevenson, S. A.

    1981-01-01

    Design information that maximizes passenger comfort for propfan aircraft is presented. Predicted noise and vibration environments and the resultant passenger acceptability were studied. The effect of high frequency tactile vibration (i.e., greater than 30 Hz) on passenger reactions was analyzed. Passenger reactions to a wide range of noise with and without tactile vibration was studied. The passenger ride quality simulator was employed using subjects who evaluated either synthesized propeller noises only, or these noises combined with seat/arm vibration. The noises ranging from 80-100 dB consisted of a turbulent boundary layer noise with a factorial combination of five blade passage frequencies (50-200 Hz), two harmonic rolloffs, and three tone/noise ratios. It is indicated that passenger reaction (annoyance) to noise is not significantly changed in the presence of tactile vibration.

  3. New Magnetic Microactuator Design Based on PDMS Elastomer and MEMS Technologies for Tactile Display.

    PubMed

    Streque, Jeremy; Talbi, Abdelkrim; Pernod, Philippe; Preobrazhensky, Vladimir

    2010-01-01

    Highly efficient tactile display devices must fulfill technical requirements for tactile stimulation, all the while preserving the lightness and compactness needed for handheld operation. This paper focuses on the elaboration of highly integrated magnetic microactuators for tactile display devices. FEM simulation, conception, fabrication, and characterization of these microactuators are presented in this paper. The current demonstrator offers a 4 × 4 flexible microactuator array with a resolution of 2 mm. Each actuator is composed of a Poly (Dimethyl-Siloxane) (PDMS) elastomeric membrane, magnetically actuated by coil-magnet interaction. It represents a proof of concept for fully integrated MEMS tactile devices, with fair actuation forces provided for a power consumption up to 100 mW per microactuator. The prototypes are destined to provide both static and dynamic tactile sensations, with an optimized membrane geometry for actuation frequencies between DC and 350 Hz. On the basis of preliminary experiments, this display device can offer skin stimulations for various tactile stimuli for applications in the fields of Virtual Reality or Human-Computer Interaction (HCI). Moreover, the elastomeric material used in this device and its global compactness offer great advantages in matter of comfort of use and capabilities of integration in haptic devices.

  4. National Survey on Distracted Driving Attitudes and Behaviors - 2015

    DOT National Transportation Integrated Search

    2018-03-01

    The 2015 National Survey on Distracted Driving Attitudes and Behaviors (NSDDAB) is the third in a series of telephone surveys on distracted driving providing data to help further the understanding of driving behavior and to contribute to the developm...

  5. Le Fort III Distraction With Internal vs External Distractors: A Cephalometric Analysis.

    PubMed

    Robertson, Kevin J; Mendez, Bernardino M; Bruce, William J; McDonnell, Brendan D; Chiodo, Michael V; Patel, Parit A

    2018-05-01

    This study compares the change in midface position following Le Fort III advancement using either rigid external distraction (group 1) or internal distraction (group 2). We hypothesized that, with reference to right-facing cephalometry, internal distraction would result in increased clockwise rotation and inferior displacement of the midface. Le Fort III osteotomies and standardized distraction protocols were performed on 10 cadaveric specimens per group. Right-facing lateral cephalograms were traced and compared across time points to determine change in position at points orbitale, anterior nasal spine (ANS), A-point, and angle ANB. Institutional. Twenty cadaveric head specimens. Standard subcranial Le Fort III osteotomies were performed from a coronal approach and adequately mobilized. The specified distraction mechanism was applied and advanced by 15 mm. Changes of position were calculated at various skeletal landmarks: orbitale, ANS, A-point, and ANB. Group 1 demonstrated relatively uniform x-axis advancement with minimal inferior repositioning at the A-point, ANS, and orbitale. Group 2 demonstrated marked variation in x-axis advancement among the 3 points, along with a significant inferior repositioning and clockwise rotation of the midface ( P < .0001). External distraction resulted in more uniform advancement of the midface, whereas internal distraction resulted in greater clockwise rotation and inferior displacement. External distraction appears to provide increased vector control of the midface, which is important in creating a customized distraction plan based on the patient's individual occlusal and skeletal needs.

  6. Brain Activity and Network Interactions in the Impact of Internal Emotional Distraction.

    PubMed

    Iordan, A D; Dolcos, S; Dolcos, F

    2018-06-14

    Emotional distraction may come from the external world and from our mind, as internal distraction. Although external emotional distraction has been extensively investigated, less is known about the mechanisms associated with the impact of internal emotional distraction on cognitive performance, and those involved in coping with such distraction. These issues were investigated using a working memory task with emotional distraction, where recollected unpleasant autobiographical memories served as internal emotional distraction. Emotion regulation was manipulated by instructing participants to focus their attention either on or away from the emotional aspects of their memories. Behaviorally, focusing away from emotion was associated with better working memory performance than focusing on the recollected emotions. Functional MRI data showed reduced response in brain regions associated with the salience network, coupled with greater recruitment of executive prefrontal and memory-related temporoparietal regions, and with increased frontoparietal connectivity, when subjects focused on nonemotional contextual details of their memories. Finally, temporal dissociations were also identified between regions involved in self-referential (showing faster responses) versus context-related processing (showing delayed responses). These findings demonstrate that focused attention is an effective regulation strategy in coping with internal distraction, and are relevant for understanding clinical conditions where coping with distressing memories is dysfunctional.

  7. A new dynamic tactile display for reconfigurable braille: implementation and tests.

    PubMed

    Motto Ros, Paolo; Dante, Vittorio; Mesin, Luca; Petetti, Erminio; Del Giudice, Paolo; Pasero, Eros

    2014-01-01

    Different tactile interfaces have been proposed to represent either text (braille) or, in a few cases, tactile large-area screens as replacements for visual displays. None of the implementations so far can be customized to match users' preferences, perceptual differences and skills. Optimal choices in these respects are still debated; we approach a solution by designing a flexible device allowing the user to choose key parameters of tactile transduction. We present here a new dynamic tactile display, a 8 × 8 matrix of plastic pins based on well-established and reliable piezoelectric technology to offer high resolution (pin gap 0.7mm) as well as tunable strength of the pins displacement, and refresh rate up to 50s(-1). It can reproduce arbitrary patterns, allowing it to serve the dual purpose of providing, depending on contingent user needs, tactile rendering of non-character information, and reconfigurable braille rendering. Given the relevance of the latter functionality for the expected average user, we considered testing braille encoding by volunteers a benchmark of primary importance. Tests were performed to assess the acceptance and usability with minimal training, and to check whether the offered flexibility was indeed perceived by the subject as an added value compared to conventional braille devices. Different mappings between braille dots and actual tactile pins were implemented to match user needs. Performances of eight experienced braille readers were defined as the fraction of correct identifications of rendered content. Different information contents were tested (median performance on random strings, words, sentences identification was about 75%, 85%, 98%, respectively, with a significant increase, p < 0.01), obtaining statistically significant improvements in performance during the tests (p < 0.05). Experimental results, together with qualitative ratings provided by the subjects, show a good acceptance and the effectiveness of the proposed solution.

  8. A new dynamic tactile display for reconfigurable braille: implementation and tests

    PubMed Central

    Motto Ros, Paolo; Dante, Vittorio; Mesin, Luca; Petetti, Erminio; Del Giudice, Paolo; Pasero, Eros

    2014-01-01

    Different tactile interfaces have been proposed to represent either text (braille) or, in a few cases, tactile large-area screens as replacements for visual displays. None of the implementations so far can be customized to match users' preferences, perceptual differences and skills. Optimal choices in these respects are still debated; we approach a solution by designing a flexible device allowing the user to choose key parameters of tactile transduction. We present here a new dynamic tactile display, a 8 × 8 matrix of plastic pins based on well-established and reliable piezoelectric technology to offer high resolution (pin gap 0.7mm) as well as tunable strength of the pins displacement, and refresh rate up to 50s−1. It can reproduce arbitrary patterns, allowing it to serve the dual purpose of providing, depending on contingent user needs, tactile rendering of non-character information, and reconfigurable braille rendering. Given the relevance of the latter functionality for the expected average user, we considered testing braille encoding by volunteers a benchmark of primary importance. Tests were performed to assess the acceptance and usability with minimal training, and to check whether the offered flexibility was indeed perceived by the subject as an added value compared to conventional braille devices. Different mappings between braille dots and actual tactile pins were implemented to match user needs. Performances of eight experienced braille readers were defined as the fraction of correct identifications of rendered content. Different information contents were tested (median performance on random strings, words, sentences identification was about 75%, 85%, 98%, respectively, with a significant increase, p < 0.01), obtaining statistically significant improvements in performance during the tests (p < 0.05). Experimental results, together with qualitative ratings provided by the subjects, show a good acceptance and the effectiveness of the proposed solution

  9. Type IIIb Endoleak and Relining: A Mathematical Model of Distraction Forces.

    PubMed

    Swaelens, Charles; Poole, Robert J; Torella, Francesco; McWilliams, Richard G; England, Andrew; Fisher, Robert K

    2016-04-01

    To examine the changes in distraction force following relining of a conventional abdominal aortic stent-graft with a type IIIb endoleak using the Nellix endovascular sealing device compared to a unilateral stent-graft. Relining is often used to repair type IIIb endoleaks, but the consequences to graft stability are unknown. A mathematical model was constructed based on pressure and volume flow through the stent-grafts, incorporating recognized distraction force equations. Steady flow was presumed at peak systolic pressures to calculate the maximum distraction force, with gravity ignored. Distraction forces for 28- to 36-mm-diameter stent-graft bodies with 16-mm limbs were calculated and compared to forces following relining with single and double Nellix devices or the Renu unilateral device. Distraction forces for the 28-, 32-, and 36-mm stent-grafts prior to relining were 5.99, 10.21, and 14.99 N, respectively. Similar forces were reported after relining with bilateral Nellix devices (5.86, 10.08, and 14.86 N, respectively). However, use of a unilateral Nellix increased the distraction forces to 9.92, 14.14, and 18.92 N, respectively. These were comparable to the increase observed after relining with a Renu unilateral stent-graft (9.87, 14.09, and 18.86 N, respectively). The proportional increase in distraction force for a unilateral relining ranged from 26% to 66%, with the greatest increase noted in the smaller diameter main bodies. Relining a stent-graft with a type IIIb endoleak using bilateral Nellix devices does not increase the distraction force. However, a unilateral Nellix device or the Renu system could theoretically increase the distraction force by up to 66%, potentially risking migration and type Ia endoleak. In clinical practice, these results suggest that a relining with bilateral Nellix may have benefits over the Renu unilateral stent-graft. © The Author(s) 2016.

  10. National survey on distracted driving attitudes and behaviors : 2012.

    DOT National Transportation Integrated Search

    2013-04-01

    The 2012 National Survey on Distracted Driving Attitudes and Behaviors (NSDDAB) is the second in a series of : surveys on distracted driving that have provided data to help further the understanding of driving behavior and to : contribute to the deve...

  11. TACTILE RESPONSIVENESS PATTERNS AND THEIR ASSOCIATION WITH CORE FEATURES IN AUTISM SPECTRUM DISORDERS

    PubMed Central

    Foss-Feig, Jennifer H.; Heacock, Jessica L.; Cascio, Carissa J.

    2011-01-01

    Autism spectrum disorders (ASD) are often associated with aberrant responses to sensory stimuli, which are thought to contribute to the social, communication, and repetitive behavior deficits that define ASD. However, there are few studies that separate aberrant sensory responses by individual sensory modality to assess modality-specific associations between sensory features and core symptoms. Differences in response to tactile stimuli are prevalent in ASD, and tactile contact early in infancy is a foundation for the development of social and communication skills affected by ASD. We assessed the association between three aberrant patterns of tactile responsiveness (hyper-responsiveness, hypo-responsiveness, sensory seeking) and core symptoms of ASD. Both sensory and core features were measured with converging methods including both parent-report and direct observation. Our results demonstrate that for the tactile modality, sensory hypo-responsiveness correlates strongly with increased social and communication impairments, and to a lesser degree, repetitive behaviors. Sensory seeking was found to correlate strongly with social impairment, nonverbal communication impairment, and repetitive behaviors. Surprisingly, tactile hyper-responsiveness did not significantly correlate with any core features of ASD. This differential association between specific tactile processing patterns and core features provides an important step in defining the significance of sensory symptoms in ASD, and may be useful in the development of sensory–based approaches for early detection and intervention. PMID:22059092

  12. Spatially digitized tactile pressure sensors with tunable sensitivity and sensing range.

    PubMed

    Choi, Eunsuk; Sul, Onejae; Hwang, Soonhyung; Cho, Joonhyung; Chun, Hyunsuk; Kim, Hongjun; Lee, Seung-Beck

    2014-10-24

    When developing an electronic skin with touch sensation, an array of tactile pressure sensors with various ranges of pressure detection need to be integrated. This requires low noise, highly reliable sensors with tunable sensing characteristics. We demonstrate the operation of tactile pressure sensors that utilize the spatial distribution of contact electrodes to detect various ranges of tactile pressures. The device consists of a suspended elastomer diaphragm, with a carbon nanotube thin-film on the bottom, which makes contact with the electrodes on the substrate with applied pressure. The electrodes separated by set distances become connected in sequence with tactile pressure, enabling consecutive electrodes to produce a signal. Thus, the pressure is detected not by how much of a signal is produced but by which of the electrodes is registering an output. By modulating the diaphragm diameter, and suspension height, it was possible to tune the pressure sensitivity and sensing range. Also, adding a fingerprint ridge structure enabled the sensor to detect the periodicity of sub-millimeter grating patterns on a silicon wafer.

  13. Maternal Distraction During Breast- and Bottle Feeding Among WIC and non-WIC Mothers.

    PubMed

    Ventura, Alison K; Teitelbaum, Simone

    To explore the prevalence and correlates of maternal distraction during infant feeding within a sample of mothers enrolled or not in the Special Supplemental Nutrition Program for Woman, Infants, and Children (WIC). Mothers kept diaries of their infants' feeding patterns. Mothers (n = 75) with infants aged ≤6 months. Within the diaries, mothers recorded what else, if anything, they did during the feeding. Mothers also completed questionnaires on demographics, feeding styles, and infant temperament and eating behaviors. Mothers' responses were coded into thematic categories. Feedings were classified as distracted when the mothers reported doing something other than feeding and/or interacting with the infant. Logistic regression was used to explore whether mothers exhibited different levels of distraction when breastfeeding (BF) vs bottle feeding. The researchers used multiple stepwise regression to explore associations between distracted feeding and characteristics of mothers and infants. Distractions were reported during 43% of feedings; 26% involved technological distractors. Mothers who were multiparous and perceived that their infants had greater appetites reported greater levels of any distraction during feeding. Mothers who were of racial/ethnic minorities, adhered to laissez faire feeding style, had younger infants, and perceived their infants to have lower food responsiveness and greater appetite reported greater levels of technological distraction. Being enrolled in WIC was not associated with mothers' levels of distracted feeding. Mothers reported a wide variety of distractions during both BF and bottle feeding; higher levels of distraction were associated with characteristics of both mothers and infants. Further research is needed to understand whether and how maternal distraction affects feeding outcomes. Awareness of such distractions and their potential impact would be useful to practitioners working with pregnant and postpartum women. Copyright

  14. Deadly distractions.

    PubMed

    Zuzek, Crystal

    2013-04-01

    In 2011, the National Transportation Safety Board urged all states to ban the use of portable electronic devices while driving, including hand-held and hands-free devices. Texting while driving concerns several Texas legislators, who have filed bills, backed by the Texas Medical Association, to ban the practice. TMA physicians recognize that the use of hand-held and hands-free devices and other factors associated with distracted driving affect their patients' safety.

  15. GelSight: High-Resolution Robot Tactile Sensors for Estimating Geometry and Force

    PubMed Central

    Yuan, Wenzhen; Dong, Siyuan; Adelson, Edward H.

    2017-01-01

    Tactile sensing is an important perception mode for robots, but the existing tactile technologies have multiple limitations. What kind of tactile information robots need, and how to use the information, remain open questions. We believe a soft sensor surface and high-resolution sensing of geometry should be important components of a competent tactile sensor. In this paper, we discuss the development of a vision-based optical tactile sensor, GelSight. Unlike the traditional tactile sensors which measure contact force, GelSight basically measures geometry, with very high spatial resolution. The sensor has a contact surface of soft elastomer, and it directly measures its deformation, both vertical and lateral, which corresponds to the exact object shape and the tension on the contact surface. The contact force, and slip can be inferred from the sensor’s deformation as well. Particularly, we focus on the hardware and software that support GelSight’s application on robot hands. This paper reviews the development of GelSight, with the emphasis in the sensing principle and sensor design. We introduce the design of the sensor’s optical system, the algorithm for shape, force and slip measurement, and the hardware designs and fabrication of different sensor versions. We also show the experimental evaluation on the GelSight’s performance on geometry and force measurement. With the high-resolution measurement of shape and contact force, the sensor has successfully assisted multiple robotic tasks, including material perception or recognition and in-hand localization for robot manipulation. PMID:29186053

  16. Tactile cueing effects on performance in simulated aerial combat with high acceleration.

    PubMed

    van Erp, Jan B F; Eriksson, Lars; Levin, Britta; Carlander, Otto; Veltman, J A; Vos, Wouter K

    2007-12-01

    Recent evidence indicates that vibrotactile displays can potentially reduce the risk of sensory and cognitive overload. Before these displays can be introduced in super agile aircraft, it must be ascertained that vibratory stimuli can be sensed and interpreted by pilots subjected to high G loads. Each of 9 pilots intercepted 32 targets in the Swedish Dynamic Flight Simulator. Targets were indicated on simulated standard Gripen visual displays. In addition, in half of the trials target direction was also displayed on a 60-element tactile torso display. Performance measures and subjective ratings were recorded. Each pilot pulled G peaks above +8 Gz. With tactile cueing present, mean reaction time was reduced from 1458 ms (SE = 54) to 1245 ms (SE = 88). Mean total chase time for targets that popped up behind the pilot's aircraft was reduced from 13 s (SE = 0.45) to 12 s (SE = 0.41). Pilots rated the tactile display favorably over the visual displays at target pop-up on the easiness of detecting a threat presence and on the clarity of initial position of the threats. This study is the first to show that tactile display information is perceivable and useful in hypergravity (up to +9 Gz). The results show that the tactile display can capture attention at threat pop-up and improve threat awareness for threats in the back, even in the presence of high-end visual displays. It is expected that the added value of tactile displays may further increase after formal training and in situations of unexpected target pop-up.

  17. Behavioral analysis of preterm neonates included in a tactile and kinesthetic stimulation program during hospitalization.

    PubMed

    Ferreira, Andréia M; Bergamasco, Niélsy H P

    2010-01-01

    To evaluate the effect of tactile and kinesthetic stimulation on behavioral and clinical development in preterm neonates while still in the hospital. Thirty-two clinically stable preterm infants weighing <2.500 grams, with no significant perinatal asphyxia, were allocated to two groups: a control group (CG) in which no intervention was made (n=16) and a study group (SG) in which the newborn infants received tactile and kinesthetic stimulation (n=16). Data on the infants' clinical progress were collected from medical charts and behavioral evaluations by means of a series of weekly, eight-minute films recorded from the time of inclusion into the study until hospital discharge. There was a trend towards a shorter duration of hospital stay, increased daily weight gain and a predominance of self-regulated behavior (regular breathing, state of alertness, balanced tonus, a range of postures, coordinated movements, hand-to-face movement control, suction, grip, support) in infants in the SG. With respect to motor control, comparative analysis of postconceptional ages according to age-bracket (I - 31-33 weeks 6/7; II - 34-36 weeks 6/7; and III - 37-39 weeks 6/7) revealed balanced tonus and coordinated voluntary movements in all three periods, a longer time spent in a range of postures (age bracket I) or in flexion (age bracket II) and more regular breathing in age bracket I in the SG. In the hospital, tactile and kinesthetic stimulation was shown to have a positive effect, contributing towards adjustment and self-regulation of behavior in the preterm newborn infant. Article registered in the Australian New Zealand Clinical Trials Registry (ANZCTR) under the number ACTRN12610000133033.

  18. Le Fort I Maxillary Advancement Using Distraction Osteogenesis

    PubMed Central

    Combs, Patrick D.; Harshbarger, Raymond J.

    2014-01-01

    Treatment of maxillary hypoplasia has traditionally involved conventional Le Fort I osteotomies and advancement. Advancements of greater than 10 mm risk significant relapse. This risk is greater in the cleft lip and palate population, whose anatomy and soft tissue scarring from prior procedures contributes to instability of conventional maxillary advancement. Le Fort I advancement with distraction osteogenesis has emerged as viable, stable treatment modality correction of severe maxillary hypoplasia in cleft, syndromic, and noncleft patients. In this article, the authors provide a review of current data and recommendations concerning Le Fort I advancement with distraction osteogenesis. In addition, they outline their technique for treating severe maxillary hypoplasia with distraction osteogenesis using internal devices. PMID:25383054

  19. Acoustic Tactile Representation of Visual Information

    NASA Astrophysics Data System (ADS)

    Silva, Pubudu Madhawa

    Our goal is to explore the use of hearing and touch to convey graphical and pictorial information to visually impaired people. Our focus is on dynamic, interactive display of visual information using existing, widely available devices, such as smart phones and tablets with touch sensitive screens. We propose a new approach for acoustic-tactile representation of visual signals that can be implemented on a touch screen and allows the user to actively explore a two-dimensional layout consisting of one or more objects with a finger or a stylus while listening to auditory feedback via stereo headphones. The proposed approach is acoustic-tactile because sound is used as the primary source of information for object localization and identification, while touch is used for pointing and kinesthetic feedback. A static overlay of raised-dot tactile patterns can also be added. A key distinguishing feature of the proposed approach is the use of spatial sound (directional and distance cues) to facilitate the active exploration of the layout. We consider a variety of configurations for acoustic-tactile rendering of object size, shape, identity, and location, as well as for the overall perception of simple layouts and scenes. While our primary goal is to explore the fundamental capabilities and limitations of representing visual information in acoustic-tactile form, we also consider a number of relatively simple configurations that can be tied to specific applications. In particular, we consider a simple scene layout consisting of objects in a linear arrangement, each with a distinct tapping sound, which we compare to a ''virtual cane.'' We will also present a configuration that can convey a ''Venn diagram.'' We present systematic subjective experiments to evaluate the effectiveness of the proposed display for shape perception, object identification and localization, and 2-D layout perception, as well as the applications. Our experiments were conducted with visually blocked

  20. Tactile pavement for guiding walking direction: An assessment of heading direction and gait stability.

    PubMed

    Pluijter, Nanda; de Wit, Lieke P W; Bruijn, Sjoerd M; Plaisier, Myrthe A

    2015-10-01

    For maintaining heading direction while walking we heavily rely on vision. Therefore, walking in the absence of vision or with visual attention directed elsewhere potentially leads to dangerous situations. Here we investigated whether tactile information from the feet can be used as a (partial) substitute for vision in maintaining a stable heading direction. If so, participants should be better able to keep a constant heading direction on tactile pavement that indicates directionality than on regular flat pavement. However, such a pavement may also be destabilizing. Thus we asked participants to walk straight ahead on regular pavement, and on tactile pavement (tiles with ridges along the walking direction) while varying the amount of vision. We assessed the effects of the type of pavement as well as the amount of vision on the variability of the heading direction as well as gait stability. Both of these measures were calculated from accelerations and angular velocities recorded from a smartphone attached to the participants trunk. Results showed that on tactile pavement participants had a less variations in their heading direction than on regular pavement. The drawback, however, was that the tactile pavement used in this study decreased gait stability. In sum, tactile pavement can be used as a partial substitute for vision in maintaining heading direction, but it can also decrease gait stability. Future work should focus on designing tactile pavement that does provided directional clues, but is less destabilizing. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Intuitive tactile zooming for graphics accessed by individuals who are blind and visually impaired.

    PubMed

    Rastogi, Ravi; Pawluk, T V Dianne; Ketchum, Jessica

    2013-07-01

    One possibility of providing access to visual graphics for those who are visually impaired is to present them tactually: unfortunately, details easily available to vision need to be magnified to be accessible through touch. For this, we propose an "intuitive" zooming algorithm to solve potential problems with directly applying visual zooming techniques to haptic displays that sense the current location of a user on a virtual diagram with a position sensor and, then, provide the appropriate local information either through force or tactile feedback. Our technique works by determining and then traversing the levels of an object tree hierarchy of a diagram. In this manner, the zoom steps adjust to the content to be viewed, avoid clipping and do not zoom when no object is present. The algorithm was tested using a small, "mouse-like" display with tactile feedback on pictures representing houses in a community and boats on a lake. We asked the users to answer questions related to details in the pictures. Comparing our technique to linear and logarithmic step zooming, we found a significant increase in the correctness of the responses (odds ratios of 2.64:1 and 2.31:1, respectively) and usability (differences of 36% and 19%, respectively) using our "intuitive" zooming technique.

  2. Computer-Simulated Arthroscopic Knee Surgery: Effects of Distraction on Resident Performance.

    PubMed

    Cowan, James B; Seeley, Mark A; Irwin, Todd A; Caird, Michelle S

    2016-01-01

    Orthopedic surgeons cite "full focus" and "distraction control" as important factors for achieving excellent outcomes. Surgical simulation is a safe and cost-effective way for residents to practice surgical skills, and it is a suitable tool to study the effects of distraction on resident surgical performance. This study investigated the effects of distraction on arthroscopic knee simulator performance among residents at various levels of experience. The authors hypothesized that environmental distractions would negatively affect performance. Twenty-five orthopedic surgery residents performed a diagnostic knee arthroscopy computer simulation according to a checklist of structures to identify and tasks to complete. Participants were evaluated on arthroscopy time, number of chondral injuries, instances of looking down at their hands, and completion of checklist items. Residents repeated this task at least 2 weeks later while simultaneously answering distracting questions. During distracted simulation, the residents had significantly fewer completed checklist items (P<.02) compared with the initial simulation. Senior residents completed the initial simulation in less time (P<.001), with fewer chondral injuries (P<.005) and fewer instances of looking down at their hands (P<.012), compared with junior residents. Senior residents also completed 97% of the diagnostic checklist, whereas junior residents completed 89% (P<.019). During distracted simulation, senior residents continued to complete tasks more quickly (P<.006) and with fewer instances of looking down at their hands (P<.042). Residents at all levels appear to be susceptible to the detrimental effects of distraction when performing arthroscopic simulation. Addressing even straightforward questions intraoperatively may affect surgeon performance. Copyright 2016, SLACK Incorporated.

  3. Artery cross-clamping during laparoscopic vascular surgeries; a computational tactile sensing approach.

    PubMed

    Pahlavan, Pedram; Najarian, Siamak; Afshari, Elnaz; Moini, Majid

    2013-01-01

    Artificial palpation is one of the most valuable achievements of artificial tactile sensing approach that can be used in various fields of medicine and more specifically in surgery. These techniques cause different surgical maneuvers to be done more precisely and noninvasively. In this study, considering the present problems and limitations of cross-clamping an artery during laparoscopic vascular surgeries, a new tactile sensory system will be introduced.Having imitated surgeon's palpation during open vascular surgeries and modeled it conceptually, the optimal amount of the total angular displacement of each robot joint in order to cross-clamping an artery without damaging to the artery surrounding tissues will be calculated. The elastic governing equation of contact occurred between the tactile sensor placed on the first link of the robot and the surrounding tissues around the artery were developed. A finite element model is coupled with genetic algorithm optimization method so that the normal stress and displacements in contact surface of the robot and artery's surrounding tissues would be minimized. Thus, reliability and accuracy of artificial tactile sensing method in artery cross-clamping will be demonstrated. Finally, the functional principles of the new tactile system capable of cross-clamping an artery during laparoscopic surgeries will be presented.

  4. Impact of intraoperative distractions on patient safety: a prospective descriptive study using validated instruments.

    PubMed

    Sevdalis, Nick; Undre, Shabnam; McDermott, James; Giddie, Jasdeep; Diner, Lila; Smith, Gillian

    2014-04-01

    There is emerging evidence indicating that distractions in the operating room (OR) are prevalent. Studies have shown a negative impact of distractions, but they have been conducted mostly with residents in simulated environments. We tested the hypothesis that intraoperative distractions are associated with deterioration in patient safety checks in the OR. We assessed 24 elective urologic procedures. Blinded trained assessors (two surgeons, one psychologist) used validated instruments to prospectively assess in vivo frequency and severity of distractions (related to communication, phones/pagers, equipment/provisions, OR environment, other hospital departments, or a member of the OR team) and completion of safety-related tasks (related to the patient, equipment, and communication). Descriptive and correlational analyses were conducted. Mean case duration was 70 min (mean intraoperative time 31 min). A mean of 4.0 communication distractions (range 0-9) and 2.48 other distractions (range 0-5) were recorded per case (distraction rate of one per 10 min). Distractions from external visitors (addressed to the entire team or the surgeon) and distractions due to lack of coordination between hospital departments were most disruptive. Regarding safety checks, patient tasks were completed most often (85-100 %) followed by equipment tasks (75-100 %) and communication tasks (55-90 %). Correlational analyses showed that more frequent/severe communication distractions were linked to lower completion of patient checks intraoperatively (median rho -0.56, p < 0.05). Distractions are prevalent in ORs and in this study were linked to deterioration in intraoperative patient safety checks. Surgeons should be mindful of their tolerance to distractions. Surgical leadership can help control distractions and reduce their potential impact on patient safety and performance.

  5. Results of calcaneocuboid distraction arthrodesis.

    PubMed

    Grunander, Todd R; Thordarson, David B

    2012-03-01

    One powerful method of reconstructing an adult acquired flatfoot deformity is a calcaneocuboid distraction arthrodesis. We performed a retrospective review of a small series of patients who underwent a calcaneocuboid distraction arthrodesis with a femoral head allograft. Sixteen feet (14 patients) were identified with an average follow up of 23 months (8-39 months) and an average age of 43 years (16-60 years). A calcaneocuboid distraction arthrodesis was performed with a femoral head allograft, secured with a 3 hole 1/3 tubular plate with 7 of the grafts being supplemented with platelet rich plasma (PRP). Patients were kept non-weight bearing for 6 weeks with an additional 6 weeks in a walking cast or boot. Plain radiographs and if necessary a CT or MRI were used to evaluate for union. Seven of the 16 feet developed a nonunion. Five of 9 patients without PRP developed a nonunion vs 2 of 7 patients where PRP was used. Due to the unacceptably high complication rate with this procedure, the authors have abandoned this procedure. If an allograft is to be used for a calcaneocuboid arthrodesis, the authors strongly recommend using rigid locking fixation with a longer period of protected immobilization. Copyright © 2011 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  6. Management of Cleft Maxillary Hypoplasia with Anterior Maxillary Distraction: Our Experience.

    PubMed

    Chacko, Tojan; Vinod, Sankar; Mani, Varghese; George, Arun; Sivaprasad, K K

    2014-12-01

    Maxillary hypoplasia is a common developmental problem in cleft lip and palate deformities. Since 1970s these deformities have traditionally been corrected by means of orthognathic surgery. Management of skeletal deformities in the maxillofacial region has been an important challenge for maxillofacial surgeons and orthodontists. Distraction osteogenesis is a surgical technique that uses body's own repairing mechanisms for optimal reconstruction of the tissues. We present four cases of anterior maxillary distraction osteogenesis with tooth borne distraction device-Hyrax, which were analyzed retrospectively for the efficacy of the tooth borne device-Hyrax and skeletal stability of distracted anterior maxillary segment.

  7. Sulfasalazine Blocks the Development of Tactile Allodynia in Diabetic Rats

    PubMed Central

    Berti-Mattera, Liliana N.; Kern, Timothy S.; Siegel, Ruth E.; Nemet, Ina; Mitchell, Rochanda

    2008-01-01

    OBJECTIVE—Diabetic neuropathy is manifested either by loss of nociception (painless syndrome) or by mechanical hyperalgesia and tactile allodynia (pain in response to nonpainful stimuli). While therapies with vasodilators or neurotrophins reverse some functional and metabolic abnormalities in diabetic nerves, they only partially ameliorate neuropathic pain. The reported link between nociception and targets of the anti-inflammatory drug sulfasalazine prompted us to investigate its effect on neuropathic pain in diabetes. RESEARCH DESIGN AND METHODS—We examined the effects of sulfasalazine, salicylates, and the poly(ADP-ribose) polymerase-1 inhibitor PJ34 on altered nociception in streptozotocin-induced diabetic rats. We also evaluated the levels of sulfasalazine targets in sciatic nerves and dorsal root ganglia (DRG) of treated animals. Finally, we analyzed the development of tactile allodynia in diabetic mice lacking expression of the sulfasalazine target nuclear factor-κB (NF-κB) p50. RESULTS—Sulfasalazine completely blocked the development of tactile allodynia in diabetic rats, whereas relatively minor effects were observed with other salicylates and PJ34. Along with the behavioral findings, sciatic nerves and DRG from sulfasalazine-treated diabetic rats displayed a decrease in NF-κB p50 expression compared with untreated diabetic animals. Importantly, the absence of tactile allodynia in diabetic NF-κB p50−/− mice supported a role for NF-κB in diabetic neuropathy. Sulfasalazine treatment also increased inosine levels in sciatic nerves of diabetic rats. CONCLUSIONS—The complete inhibition of tactile allodynia in experimental diabetes by sulfasalazine may stem from its ability to regulate both NF-κB and inosine. Sulfasalazine might be useful in the treatment of nociceptive alterations in diabetic patients. PMID:18633115

  8. Lateralized ultradian rhythms: evidence from tactile discrimination of either hand.

    PubMed

    Meier-Koll, A

    1998-12-01

    Endogenous ultradian rhythms with periods of one or a few hours affect not only on physiological and behavioural functions but also perception and cognition. In particular, lateralized ultradian rhythms which seem to operate separately in the right and left hemispheres of the brain can be monitored by testing the tactile discrimination of the contralateral hand. The present paper is based on two subsequent studies: First, ultradian rhythms in tactile discrimination of either hand were examined in German subjects under laboratory conditions. Considerably different ultradian periods of right and left-handed tactile error rate were found in men but not in women. In a second study, a group of Kenyan Masai shepherds were tested while the subjects were leading herds on daily feeding routes through a savanna habitat. They showed ultradian periods of about 2 hours in tactile discrimination of either hand. Since the right hemisphere is specialized for visuospatial, the left for verbal processing lateralized ultradian rhythms may serve for a long-scale timing of neural processes underlying spatial and semantic mapping of the environment. Sex difference in German subjects and lateral differences found in left-handed (right-hemispheric) ultradian rhythms of German and Masai subjects are discussed from this point of view.

  9. Evaluation of bone healing in femurs lengthened via the gradual distraction method.

    PubMed

    Jochymek, Jiri; Gal, Petr

    2007-06-01

    Treatment of leg length inequality via lengthening of the shorter extremity is an infrequent orthopedic procedure due to the requirement of special distraction devices and possible serious complications. Essential qualitative changes in operative technique development are associated with the name of G. A. Ilizarov, who paved the way for the autoregenerate gradual distraction method in the 1950s. In the years 1990 through 2006 a total of 57 patients underwent femur lengthening via gradual distraction using various types of external fixators at the Department of Pediatric Surgery, Orthopedics, and Traumatology, Faculty Hospital in Brno. The quality of bone healing was monitored and a number of parameters followed and statistically evaluated using regularly scheduled X-ray examinations. In 11 cases we had to remove the external fixator following the distraction phase, perform an osteosynthesis via a splint and fill the distraction gap via spongioplasty. The bone healing was satisfactory in the remaining 46 patients and the lengthened bone required no other fixation method. The analysis showed statistically significant deceleration in bone healing following distraction in female patients over 12 years of age, and in boys over 14 years of age. Lack of periosteal callus five weeks after surgery always signified serious problems in further healing. Severe complications were recorded in 11 cases during the distraction phase, and in 9 cases after the removal of the distraction apparatus. The aim of this report was to present the results of our study of distraction gap bone healing using the gradual lengthening approach.

  10. Making your skin crawl: The role of tactile sensitivity in disease avoidance.

    PubMed

    Hunt, David Francis; Cannell, Grace; Davenhill, Nicholas A; Horsford, Stephanie A; Fleischman, Diana S; Park, Justin H

    2017-07-01

    Mounting evidence indicates that animals, including humans, have evolved a behavioral disease-avoidance system designed to facilitate the detection and avoidance of sources of pathogens, and that this system interacts with physiological defenses. The skin acts as an important anatomical barrier, yet little research has investigated the role of tactile sensitivity in disease avoidance. Increased tactile sensitivity in the presence of potential sources of pathogens may facilitate prophylactic behaviors such as self-grooming. Across multiple studies, we tested the hypothesis that the induction of disgust-the key emotion underlying disease avoidance-may lead to greater tactile sensitivity compared to control conditions. A nonsignificant trend was found in a pilot study, which was replicated (and found to be significant) in Studies 1 and 2. To our knowledge, these results are the first to demonstrate disgust-induced changes in tactile sensitivity, and they contribute to the growing literature on the integrated evolved defenses against infectious disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. The potential effect of technology and distractions on undergraduate students' concentration.

    PubMed

    Attia, Najya A; Baig, Lubna; Marzouk, Yousef I; Khan, Anwar

    2017-01-01

    In the present era, it is difficult to keep the concentration of college students at its maximum potential during the class time, as there are many distractions that negatively impact students' concentration and prevent optimal learning. Technologies such as laptops and cell phones have invaded the classroom, raising considerable concerns about their effects on college students' attention in the classroom. Despite these concerns, no research has been done in Saudi Arabia on the effects of technology and other types of classroom distractions on students' concentration. In the current study, we have attempted to identify students' perceptions of major distractions in the classroom based on seventeen internally (self-produced) and twenty-four externally produced classroom situations. The students participating in this study rated the degree to which each distraction interferes with their concentration on the class materials and their ability to learn. Data were collected through surveys of 265 students (66 and 199 students from medical and basic classes, respectively), including 97 females and 168 males 17-23 years of age from the academic years 2010 to 2014. A validated self-administered questionnaire was handed to the students in the classroom. The students were asked to report and rate the classroom distraction produced by 24 external internal distracters (Table-II), on a 5-point scale. The results revealed that ringing cell phones in the class were the most commonly reported electronic external distractor for 68% of students, and 21% of them reported being extremely distracted by this noise. Having an instructor who is difficult to understand was the most commonly reported external behavioral distractor for 75% of students, and 48% of them rated this as extremely distracting. Students talking in class were the most self-produced distractor for 72% of students; negatively impacting their concentration and ability to learn, and 42% of them rated it as an extreme

  12. The potential effect of technology and distractions on undergraduate students’ concentration

    PubMed Central

    Attia, Najya A.; Baig, Lubna; Marzouk, Yousef I.; Khan, Anwar

    2017-01-01

    Background and Objectives: In the present era, it is difficult to keep the concentration of college students at its maximum potential during the class time, as there are many distractions that negatively impact students’ concentration and prevent optimal learning. Technologies such as laptops and cell phones have invaded the classroom, raising considerable concerns about their effects on college students’ attention in the classroom. Despite these concerns, no research has been done in Saudi Arabia on the effects of technology and other types of classroom distractions on students’ concentration. In the current study, we have attempted to identify students’ perceptions of major distractions in the classroom based on seventeen internally (self-produced) and twenty-four externally produced classroom situations. Methods: The students participating in this study rated the degree to which each distraction interferes with their concentration on the class materials and their ability to learn. Data were collected through surveys of 265 students (66 and 199 students from medical and basic classes, respectively), including 97 females and 168 males 17–23 years of age from the academic years 2010 to 2014. A validated self-administered questionnaire was handed to the students in the classroom. The students were asked to report and rate the classroom distraction produced by 24 external internal distracters (Table-II), on a 5-point scale. Results: The results revealed that ringing cell phones in the class were the most commonly reported electronic external distractor for 68% of students, and 21% of them reported being extremely distracted by this noise. Having an instructor who is difficult to understand was the most commonly reported external behavioral distractor for 75% of students, and 48% of them rated this as extremely distracting. Students talking in class were the most self-produced distractor for 72% of students; negatively impacting their concentration and

  13. Clinical and experimental study of TMJ distraction: preliminary results.

    PubMed

    Festa, F; Galluccio, G

    1998-01-01

    A physiotherapeutic approach, with manual maneuvers and/or distraction appliances, is indicated in the treatment of temporomandibular joint disorders (TMDs) to prevent the progressive fibrosis of the muscle fibers. In this article, the authors report preliminary results of experimental and clinical studies conducted to assess the real effect of distraction in temporomandibular joint disorders. The experimental invivo studies confirmed the structural alteration due to compression and distraction on the capsular and condylar tissues. Clinical cases are reported to show the increase of the intraarticular vertical dimension, with a forward and downward movement of the condyles in a more physiologic condition.

  14. Anterior insula coordinates hierarchical processing of tactile mismatch responses

    PubMed Central

    Allen, Micah; Fardo, Francesca; Dietz, Martin J.; Hillebrandt, Hauke; Friston, Karl J.; Rees, Geraint; Roepstorff, Andreas

    2016-01-01

    The body underlies our sense of self, emotion, and agency. Signals arising from the skin convey warmth, social touch, and the physical characteristics of external stimuli. Surprising or unexpected tactile sensations can herald events of motivational salience, including imminent threats (e.g., an insect bite) and hedonic rewards (e.g., a caressing touch). Awareness of such events is thought to depend upon the hierarchical integration of body-related mismatch responses by the anterior insula. To investigate this possibility, we measured brain activity using functional magnetic resonance imaging, while healthy participants performed a roving tactile oddball task. Mass-univariate analysis demonstrated robust activations in limbic, somatosensory, and prefrontal cortical areas previously implicated in tactile deviancy, body awareness, and cognitive control. Dynamic Causal Modelling revealed that unexpected stimuli increased the strength of forward connections along a caudal to rostral hierarchy—projecting from thalamic and somatosensory regions towards insula, cingulate and prefrontal cortices. Within this ascending flow of sensory information, the AIC was the only region to show increased backwards connectivity to the somatosensory cortex, augmenting a reciprocal exchange of neuronal signals. Further, participants who rated stimulus changes as easier to detect showed stronger modulation of descending PFC to AIC connections by deviance. These results suggest that the AIC coordinates hierarchical processing of tactile prediction error. They are interpreted in support of an embodied predictive coding model where AIC mediated body awareness is involved in anchoring a global neuronal workspace. PMID:26584870

  15. An Adaptation-Induced Repulsion Illusion in Tactile Spatial Perception

    PubMed Central

    Li, Lux; Chan, Arielle; Iqbal, Shah M.; Goldreich, Daniel

    2017-01-01

    Following focal sensory adaptation, the perceived separation between visual stimuli that straddle the adapted region is often exaggerated. For instance, in the tilt aftereffect illusion, adaptation to tilted lines causes subsequently viewed lines with nearby orientations to be perceptually repelled from the adapted orientation. Repulsion illusions in the nonvisual senses have been less studied. Here, we investigated whether adaptation induces a repulsion illusion in tactile spatial perception. In a two-interval forced-choice task, participants compared the perceived separation between two point-stimuli applied on the forearms successively. Separation distance was constant on one arm (the reference) and varied on the other arm (the comparison). In Experiment 1, we took three consecutive baseline measurements, verifying that in the absence of manipulation, participants’ distance perception was unbiased across arms and stable across experimental blocks. In Experiment 2, we vibrated a region of skin on the reference arm, verifying that this focally reduced tactile sensitivity, as indicated by elevated monofilament detection thresholds. In Experiment 3, we applied vibration between the two reference points in our distance perception protocol and discovered that this caused an illusory increase in the separation between the points. We conclude that focal adaptation induces a repulsion aftereffect illusion in tactile spatial perception. The illusion provides clues as to how the tactile system represents spatial information. The analogous repulsion aftereffects caused by adaptation in different stimulus domains and sensory systems may point to fundamentally similar strategies for dynamic sensory coding. PMID:28701936

  16. Investigating saccade programming in the praying mantis Tenodera aridifolia using distracter interference paradigms.

    PubMed

    Yamawaki, Yoshifumi

    2006-10-01

    To investigate the saccadic system in the mantis, I applied distracter interference paradigms. These involved presenting the mantis with a fixation target and one or several distracters supposed to affect saccades towards the target. When a single target was presented, a medium-sized target located in its lower visual field elicited higher rates of saccade response. This preference for target size and position was also observed when a target and a distracter were presented simultaneously. That is, the mantis chose and fixated the target rather than a distracter that was much smaller or larger than the target, or was located above the target. Furthermore, the mantis' preference was not affected by increasing the number of distracters. However, the presence of the distracter decreased the occurrence rate of saccade and increased the response time to saccade. I conclude that distracter interference paradigms are an effective way of investigating the visual processing underlying saccade generation in the mantis. Possible mechanisms of saccade generation in the mantis are discussed.

  17. [Mandibular-driven simultaneous maxillo-mandibular distraction for hemifacial microsomia with rapid prototyping technology].

    PubMed

    Gao, Quan-Wen; Song, Hui-Feng; Xu, Ming-Huo; Liu, Chun-Ming; Chai, Jia-Ke

    2013-11-01

    To explore the clinical application of mandibular-driven simultaneous maxillo-mandihular distraction to correct hemifacial microsomia with rapid prototyping technology. The patient' s skull resin model was manufactured with rapid prototyping technology. The osteotomy was designed on skull resin model. According to the preoperative design, the patients underwent Le Fort I osteotomy and mandibular ramus osteotomy. The internal mandible distractor was embedded onto the osteotomy position. The occlusal titanium pin was implanted. Distraction were carried out by mandibular-driven simultaneous maxillo-mandihular distraction 5 days after operation. The distraction in five patients was complete as designed. No infection and dysosteogenesis happened. The longest distance of distraction was 28 mm, and the shortest distance was 16 mm. The facial asymmetry deformity was significantly improved at the end of distraction. The ocelusal plane of patients obviously improved. Rapid prototyping technology is helpful to design precisely osteotomy before operation. Mandibular-driven simultaneous maxillo-mandibular distraction can correct hemifacial microsomia. It is worth to clinical application.

  18. Effects of individual differences on the efficacy of different distracters during visual sexual stimulation in women.

    PubMed

    Roberts, Verena M; Prause, Nicole

    2012-02-01

    Distractions from sexual cues have been shown to decrease the sexual response, but it is unclear how distracters decrease sexual response. Individual differences may modulate the efficacy of distracters. Forty women viewed three sexual films while their labial temperature and continuous self-reported sexual arousal were monitored. One sexual film had simultaneous verbal distracters concerning dissatisfaction with one's physical appearance (higher salience distracter), a second had distracters concerning daily chores (lower salience distracter), and the third sexual film had no distracters. Participant's reporting greater relationship satisfaction and more communication with their partner about their own physical appearance were expected to decrease the efficacy (increased sexual arousal) of the distracters concerning physical appearance. Contrary to expectations, women who received less feedback about their body from their partners reported less sexual arousal during a sexual film with body distracters than a sexual film with general distracters or a sexual film with no distracters. All women exhibited lower labial temperature in Minutes 2 and 3 of the sexual film with body image distracters as compared to the other two sexual films. Possible explanations explored include self-verification theory and individual differences in the indicators that women consider when rating their sexual arousal.

  19. Reputation management promotes strategic adjustment of service quality in cleaner wrasse.

    PubMed

    Binning, Sandra A; Rey, Olivia; Wismer, Sharon; Triki, Zegni; Glauser, Gaétan; Soares, Marta C; Bshary, Redouan

    2017-08-21

    Adjusting one's behaviour in response to eavesdropping bystanders is considered a sophisticated social strategy, yet the underlying mechanisms are not well studied. Cleaner wrasse, Labroides dimidiatus, cooperate by eating ectoparasites off "client" fishes, or cheat (i.e. bite) and eat client mucus. Image scoring by bystander clients generally causes cleaners from socially-complex (i.e. high cleaner and client abundance; high client species richness) habitats to increase levels of cooperation. However, some individuals may periodically provide tactile stimulation to small resident clients, which attract bystanders close that are bitten, a form of tactical deception. Cortisol injection can reproduce this pattern. Here, we tested whether cleaners from socially-complex versus simple habitats respond differently to cortisol injections in terms of their cleaning interactions with clients. We found that only cleaners from the socially-complex habitat respond to cortisol injection with strategies functioning as tactical deception: i.e. increased tactile stimulation to small clients and increased cheating of large clients relative to small ones. At the socially-simple site, where reputation management is less important, cortisol-treated fish increased their overall levels of cheating, especially of small clients. Thus, strategic adjustments to cooperative behaviour and tactical deception are likely context-dependent, forming part of general reputation management abilities in cleaner wrasse.

  20. Ankle Distraction Arthroplasty: Indications, Technique, and Outcomes.

    PubMed

    Bernstein, Mitchell; Reidler, Jay; Fragomen, Austin; Rozbruch, S Robert

    2017-02-01

    Ankle distraction is an alternative to ankle arthrodesis or total ankle arthroplasty in younger patients with arthritis. Ankle distraction involves the use of external fixation to mechanically unload the ankle joint, which allows for stable, congruent range of motion in the setting of decreased mechanical loading, potentially promoting cartilage repair. Adjunct surgical procedures are frequently done to address lower-extremity malalignment, ankle equinus contractures, and impinging tibiotalar osteophytes. Patients can bear full weight during the treatment course. The distraction frame frequently uses a hinge, and patients are encouraged to do daily range-of-motion exercises. Although the initial goal of the procedure is to delay arthrodesis, many patients achieve lasting clinical benefits, obviating the need for total ankle arthroplasty or fusion. Complications associated with external fixation are common, and patients should be counseled that clinical improvements occur slowly and often are not achieved until at least 1 year after frame removal.

  1. Distract or reappraise? Age-related differences in emotion-regulation choice.

    PubMed

    Scheibe, Susanne; Sheppes, Gal; Staudinger, Ursula M

    2015-12-01

    Does aging impact strategy choice with regard to regulating negative emotions? Based on the assumption that older adults are highly motivated to quickly defuse negative states, we predicted that older adults, relative to young adults, would show an increased preference for distraction (a cognitive disengagement strategy) over reappraisal (a cognitive engagement strategy) in the face of negative material. A stronger preference for distraction, in turn, should be associated with higher affective well-being at older ages, as it helps to avoid high physiological arousal. Young (19-28 years, n = 38) and older (65-75 years, n = 39) adults completed a laboratory task of emotion-regulation choice in which they viewed negative pictures of high and low intensity and chose between distraction and reappraisal to regulate their emotional response. Confirming predictions, age was associated with an increased preference to choose distraction over reappraisal. Among older but not young adults, the relative preference for distraction to reappraisal predicted higher state-affective well-being. In addition, across age groups, the preference for distraction over reappraisal was positively predicted by stimulus intensity and negatively by cognitive resources. Findings support the notion of an age-related shift toward disengagement strategies to regulate negative emotions, which maps onto older adults' prohedonic orientation and holds affective benefits. (c) 2015 APA, all rights reserved).

  2. Susceptibility to distraction during reading in young, young-old, and old-old adults.

    PubMed

    McGinnis, Debra

    2012-01-01

    BACKGROUND/STUDY CONTEXT: Susceptibility to distraction during reading may increase with age, resulting in comprehension errors. Neurological integrity and cognitive reserve are possible covariates of age-related distraction susceptibility. The current study investigated distraction susceptibility in three age groups (young, young-old, and old-old), and examined the covariation patterns of variable sets associated with neurological integrity and cognitive reserve. Participants responded to comprehension questions after reading stories that included semantically related or semantically unrelated distractors. Neurological integrity measures consisted of Mini-Mental State Examination, Selective Reminding, and Category Fluency. Cognitive reserve measures consisted of education and vocabulary. Old-old adults were more likely than young and young-old adults to select distractors when responding to comprehension questions (24.02%, 11.95%, 3.68%, respectively). Age-related distraction variance significantly overlapped neurological variance, and became more transparent after cognitive reserve variance was controlled. This study augments previous age-related distraction research by highlighting (a) the increase in distraction susceptibility in adults over 79, particularly when distractors are semantically related; (b) the influence of age-related neurological integrity on distraction; and (c) the possibility that education and verbal experience may decrease distraction susceptibility, consistent with cognitive reserve frameworks.

  3. Pure Amorphagnosia without Tactile Object Agnosia

    PubMed Central

    Kubota, Shinichirou; Yamada, Mai; Satoh, Hideyo; Satoh, Akira; Tsujihata, Mitsuhiro

    2017-01-01

    A 54-year-old female showed amorphagnosia without ahylognosia and tactile agnosia 40 days after the onset of right cerebral infarction. Her basic somatosensory functions were normal. The appreciation of substance qualities (hylognosia) was preserved, but the patient's inability to recognize the size and shape (morphagnosia) was confined to 2- and 3-dimensional shapes (amorphagnosia) in the left hand. However, the patient's ability to recognize real daily objects was well preserved. Brain MRI after admission showed ischemic lesions confined to the right pre- and postcentral gyri and the medial frontal cortex on DWI and FLAIR images. An analysis of SPECT images revealed that the most decreased areas were localized to the pre- and postcentral gyri, superior and inferior parietal lobules, supramarginal gyrus, and angular gyrus. Considering the previous reported cases, the responsible lesion for the impaired perception of hylognosia and morphagnosia may not necessarily be confined to the right hemisphere. To date, 5 reports (6 cases) of tactile agnosia have been published; 4 cases presented with both ahylognosia and amorphagnosia, while 1 presented with only amorphagnosia, and another showed amorphagnosia and mild ahylognosia. Our case is the first to present with only amorphagnosia without tactile agnosia. The mechanism for the well-preserved recognition of real objects may depend on the preserved hylognosia. Of note, there have been no reports showing only ahylognosia without amorphagnosia. Further studies are necessary to clarify whether or not patients with preserved hylognosia or morphagnosia retain the ability to perceive real objects. PMID:28559827

  4. Topographic generalization of tactile perceptual learning.

    PubMed

    Harrar, Vanessa; Spence, Charles; Makin, Tamar R

    2014-02-01

    Perceptual learning can improve our sensory abilities. Understanding its underlying mechanisms, in particular, when perceptual learning generalizes, has become a focus of research and controversy. Specifically, there is little consensus regarding the extent to which tactile perceptual learning generalizes across fingers. We measured tactile orientation discrimination abilities on 4 fingers (index and middle fingers of both hands), using psychophysical measures, before and after 4 training sessions on 1 finger. Given the somatotopic organization of the hand representation in the somatosensory cortex, the topography of the cortical areas underlying tactile perceptual learning can be inferred from the pattern of generalization across fingers; only fingers sharing cortical representation with the trained finger ought to improve with it. Following training, performance improved not only for the trained finger but also for its adjacent and homologous fingers. Although these fingers were not exposed to training, they nevertheless demonstrated similar levels of learning as the trained finger. Conversely, the performance of the finger that was neither adjacent nor homologous to the trained finger was unaffected by training, despite the fact that our procedure was designed to enhance generalization, as described in recent visual perceptual learning research. This pattern of improved performance is compatible with previous reports of neuronal receptive fields (RFs) in the primary somatosensory cortex (SI) spanning adjacent and homologous digits. We conclude that perceptual learning rooted in low-level cortex can still generalize, and suggest potential applications for the neurorehabilitation of syndromes associated with maladaptive plasticity in SI. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  5. Acceptance, cognitive restructuring, and distraction as coping strategies for acute pain.

    PubMed

    Kohl, Annika; Rief, Winfried; Glombiewski, Julia Anna

    2013-03-01

    Little is known about treatment mechanisms underlying acceptance strategies. Acceptance is a strategy that is expected to increase pain tolerance more than distraction, while distraction should lead to lower pain intensity. The effect of cognitive restructuring on experimental pain has not yet been investigated. The present study aimed to explore differential short-term effects of acceptance, distraction, and cognitive restructuring on pain tolerance and intensity. Pain was induced in a sample of 109 female students using a thermode. We conducted analyses of covariance with instruction as the independent variable and posttest scores on pain variables as dependent variables, covarying for pretest scores. In addition, adherence to instructions and credibility of instructions were included as covariates. Acceptance led to a higher increase in pain tolerance than did cognitive restructuring of pain-related thoughts. No differences were detected between either acceptance and distraction or distraction and cognitive restructuring with respect to pain tolerance. Distraction led to lower pain intensity compared to acceptance. Cognitive restructuring did not differ from either acceptance or distraction with respect to pain intensity. As a short-term strategy, cognitive restructuring was not as useful as acceptance in increasing pain tolerance. Further studies should evaluate the preconditions under which different strategies are most effective. This study demonstrated that acceptance was superior to cognitive restructuring in increasing tolerance for experimentally induced pain, but was inferior to distraction with respect to decreasing pain intensity. Knowledge about the types of strategies that are useful in targeting diverse pain-related outcome measures is important for efforts to refine the treatment of chronic pain. Copyright © 2013 American Pain Society. Published by Elsevier Inc. All rights reserved.

  6. Useful field of view predicts driving in the presence of distracters.

    PubMed

    Wood, Joanne M; Chaparro, Alex; Lacherez, Philippe; Hickson, Louise

    2012-04-01

    The Useful Field of View (UFOV) test has been shown to be highly effective in predicting crash risk among older adults. An important question which we examined in this study is whether this association is due to the ability of the UFOV to predict difficulties in attention-demanding driving situations that involve either visual or auditory distracters. Participants included 92 community-living adults (mean age 73.6 ± 5.4 years; range 65-88 years) who completed all three subtests of the UFOV involving assessment of visual processing speed (subtest 1), divided attention (subtest 2), and selective attention (subtest 3); driving safety risk was also classified using the UFOV scoring system. Driving performance was assessed separately on a closed-road circuit while driving under three conditions: no distracters, visual distracters, and auditory distracters. Driving outcome measures included road sign recognition, hazard detection, gap perception, time to complete the course, and performance on the distracter tasks. Those rated as safe on the UFOV (safety rating categories 1 and 2), as well as those responding faster than the recommended cut-off on the selective attention subtest (350 msec), performed significantly better in terms of overall driving performance and also experienced less interference from distracters. Of the three UFOV subtests, the selective attention subtest best predicted overall driving performance in the presence of distracters. Older adults who were rated as higher risk on the UFOV, particularly on the selective attention subtest, demonstrated poorest driving performance in the presence of distracters. This finding suggests that the selective attention subtest of the UFOV may be differentially more effective in predicting driving difficulties in situations of divided attention which are commonly associated with crashes.

  7. Promoted new bone formation in maxillary distraction osteogenesis using a tissue-engineered osteogenic material.

    PubMed

    Kinoshita, Kazuhiko; Hibi, Hideharu; Yamada, Yoichi; Ueda, Minoru

    2008-01-01

    Bilateral maxillary distraction was performed at a higher rate in rabbits to determine whether locally applied tissue-engineered osteogenic material (TEOM) enhances bone regeneration. The material was an injectable gel composed of autologous mesenchymal stem cells, which were cultured then induced to be osteogenic in character, and platelet-rich plasma (PRP). After a 5-day latency period, distraction devices were activated at a rate of 2.0 mm once daily for 4 days. Twelve rabbits were divided into 2 groups. At the end of distraction, the experimental group of rabbits received an injection of TEOM into the distracted tissue on one side, whereas, saline solution was injected into the distracted tissue on the contralateral side as the internal control. An additional control group received an injection of PRP or saline solution into the distracted tissue in the same way as the experimental group. The distraction regenerates were assessed by radiological and histomorphometric analyses. The radiodensity of the distraction gap injected with TEOM was significantly higher than that injected with PRP or saline solution at 2, 3, and 4 weeks postdistraction. The histomorphometric analysis also showed that both new bone zone and bony content in the distraction gap injected with TEOM were significantly increased when compared with PRP or saline solution. Our results demonstrated that the distraction gap injected with TEOM showed significant new bone formation. Therefore, injections of TEOM may be able to compensate for insufficient distraction gaps.

  8. Tactile Instrument for Aviation

    DTIC Science & Technology

    2000-07-30

    response times using 8 tactor locations was repeated with a dual memory /tracking task or an air combat simulation to evaluate the effectiveness of the...Global Positioning/Inertial Navigation System technologies into a single system for evaluation in an UH-60 Helicopter. A 10-event test operation was... evaluation of the following technology areas need to be pursued: • Integration of tactile instruments with helmet mounted displays and 3D audio displays

  9. When Distraction Holds Relevance: A Prospective Memory Benefit for Older Adults.

    PubMed

    Lourenço, Joana S; Maylor, Elizabeth A

    2015-06-09

    Evidence is accumulating to show that age-related increases in susceptibility to distracting information can benefit older more than young adults in several cognitive tasks. Here we focus on prospective memory (i.e., remembering to carry out future intentions) and examine the effect of presenting distracting information that is intention-related as a function of age. Young and older adults performed an ongoing 1-back working memory task to a rapid stream of pictures superimposed with to-be-ignored letter strings. Participants were additionally instructed to respond to target pictures (namely, animals) and, for half of the participants, some strings prior to the targets were intention-related words (i.e., animals). Results showed that presenting intention-related distracting information during the ongoing task was particularly advantageous for target detection in older compared to young adults. Moreover, a prospective memory benefit was observed even for older adults who showed no explicit memory for the target distracter words. We speculate that intention-related distracter information enhanced the accessibility of the prospective memory task and suggest that when distracting information holds relevance to intentions it can serve a compensatory role in prospective remembering in older adults.

  10. Condylar cartilaginous changes after mandibular distraction osteogenesis in rabbits.

    PubMed

    Ahn, Sin-Young; Kim, Su-Gwan

    2011-10-01

    The purpose of this study was to evaluate histologic and immunohistochemical changes in the condylar articular surface in response to distraction osteogenesis (DO) of the mandibular body in rabbits. A unilateral osteotomy of the mandible at the premolar area was performed in 16 rabbits. The animals were divided into 4 groups based on different distraction parameters (rate and rhythm). After a 5-day latency, the mandible was lengthened by 0.5 mm daily for 6 days (group 1); 0.5 mm twice daily for 3 days (group 2); 0.5 mm once daily for 10 days (group 3); or 0.5 mm twice daily for 5 days (group 4). All 4 groups underwent a 14-day consolidation period. Four rabbits were included in the control group. The specimens were stained with hematoxylin-eosin for histologic examination. Immunohistochemical analysis was performed to evaluate the expression of growth factors. None of the groups demonstrated any degenerative changes in the temporomandibular joint (TMJ). On the distraction side in all groups, the histopathological examination revealed a hypertrophic thickening of the cartilage zone. Prominent endochondral ossification and high active osteoblasts were observed in groups 3 and 4. On the nondistraction side, no major changes were observed excluding the appearance of osteoclasts in groups 3 and 4. The immunohistochemical analysis revealed tenascin immunoreactivity in bone marrow mesenchymal cells on the distraction side in group 4. Connexin immunoreactivity did not display a marked change in any of the groups. Osteocalcin was observed on the distraction side in group 2, which suggested that bone formation is increased. Nitric oxide synthase 2 immunoreactivity was observed on the distraction side in group 2, which is associated with stress and inflammation. The results indicated that the hypertrophy of the cartilage zone and endochondral ossification became more pronounced as the extent and rate of distraction increased. Copyright © 2011 Mosby, Inc. All rights reserved.

  11. A long-lasting improvement of tactile extinction after galvanic vestibular stimulation: two Sham-stimulation controlled case studies.

    PubMed

    Kerkhoff, Georg; Hildebrandt, Helmut; Reinhart, Stefan; Kardinal, Mareike; Dimova, Violeta; Utz, Kathrin S

    2011-01-01

    Sensory extinction is frequent and often persistent after brain damage. Previous studies have shown the transient influence of sensory stimulation on tactile extinction. In the present two case studies we investigated whether subliminal galvanic vestibular stimulation (GVS) modulates tactile extinction. GVS induces polarity-specific changes in cerebral excitability in the vestibular cortices and adjacent cortical areas in the temporo-parietal cortex via polarization of the vestibular nerves. Two patients (DL, CJ) with left-sided tactile extinction due to chronic (5 vs. 6 (1/2) years lesion age) right-hemisphere lesions (right fronto-parietal in DL, right frontal and discrete parietal in CJ) were examined. Both showed normal tactile sensitivity to light touch and yielded 90-100% correct identifications in unilateral tactile stimulations for both hands. In Baseline investigations without GVS and Sham-GVS both showed stable left-sided tactile extinction rates of 40-55% (DL) and 49-72% (CJ). In contrast, one session of right-cathodal GVS (intensity: 0.6 mA, duration: 20 min) permanently improved tactile identification of identical stimuli, while a second session with left-cathodal GVS significantly reduced left-sided extinction rates for different stimuli in DL. Patient CJ's left-sided tactile extinction was significantly improved by left-cathodal GVS (0.5 mA, 20 min) for different stimuli, while right-cathodal GVS induced a significant reduction for identical materials. In contrast, Sham-stimulation was ineffective. Improvements remained stable for at least 1 year (DL) resp. 3 weeks (CJ). Control experiments ruled out improvements in tactile extinction merely by retesting. In conclusion, chronic tactile extinction may be permanently improved by GVS in a polarity-specific way. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Distraction decreases prefrontal oxygenation: A NIRS study.

    PubMed

    Ozawa, Sachiyo; Hiraki, Kazuo

    2017-04-01

    When near-infrared spectroscopy (NIRS) is used to measure emotion-related cerebral blood flow (CBF) changes in the prefrontal cortex regions, the functional distinction of CBF changes is often difficult because NIRS is unable to measure neural activity in deeper brain regions that play major roles in emotional processing. The CBF changes could represent cognitive control of emotion and emotional responses to emotional materials. Supposing that emotion-related CBF changes in the prefrontal cortex regions during distraction are emotional responses, we examined whether oxygenated hemoglobin (oxyHb) decreases. Attention-demanding tasks cause blood flow decreases, and we thus compared the effects of visually paced tapping with different tempos, on distraction. The results showed that the oxyHb level induced by emotional stimulation decreased with fast-tempo tapping significantly more than slow-tempo tapping in ventral medial prefrontal cortex regions. Moreover, a Global-Local task following tapping showed significantly greater local-minus-global response time (RT) difference scores in the fast- and mid-tempo condition compared with those in the slow-tempo, suggesting an increased attentional focus, and decreased negative emotion. The overall findings indicate that oxyHb changes in a relatively long distraction task, as measured by NIRS, are associated with emotional responses, and oxyHb can be decreased by successfully performing attention-demanding distraction tasks. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Spatiotemporal integration for tactile localization during arm movements: a probabilistic approach.

    PubMed

    Maij, Femke; Wing, Alan M; Medendorp, W Pieter

    2013-12-01

    It has been shown that people make systematic errors in the localization of a brief tactile stimulus that is delivered to the index finger while they are making an arm movement. Here we modeled these spatial errors with a probabilistic approach, assuming that they follow from temporal uncertainty about the occurrence of the stimulus. In the model, this temporal uncertainty converts into a spatial likelihood about the external stimulus location, depending on arm velocity. We tested the prediction of the model that the localization errors depend on arm velocity. Participants (n = 8) were instructed to localize a tactile stimulus that was presented to their index finger while they were making either slow- or fast-targeted arm movements. Our results confirm the model's prediction that participants make larger localization errors when making faster arm movements. The model, which was used to fit the errors for both slow and fast arm movements simultaneously, accounted very well for all the characteristics of these data with temporal uncertainty in stimulus processing as the only free parameter. We conclude that spatial errors in dynamic tactile perception stem from the temporal precision with which tactile inputs are processed.

  14. Tactile Sun: Bringing an Invisible Universe to the Visually Impaired

    NASA Astrophysics Data System (ADS)

    Isidro, G. M.; Pantoja, C. A.

    2014-07-01

    A tactile model of the Sun has been created as a strategy for communicating astronomy to the blind or visually impaired, and as a useful outreach tool for general audiences. The model design was a collaboration between an education specialist, an astronomy specialist and a sculptor. The tactile Sun has been used at astronomy outreach events in Puerto Rico to make activities more inclusive and to increase public awareness of the needs of those with disabilities.

  15. Development of a biomimetic roughness sensor for tactile information with an elastomer

    NASA Astrophysics Data System (ADS)

    Choi, Jae-Young; Kim, Sung Joon; Moon, Hyungpil; Choi, Hyouk Ryeol; Koo, Ja Choon

    2016-04-01

    Human uses various sensational information for identifying an object. When contacting an unidentified object with no vision, tactile sensation provides a variety of information to perceive. Tactile sensation plays an important role to recognize a shape of surfaces from touching. In robotic fields, tactile sensation is especially meaningful. Robots can perform more accurate job using comprehensive tactile information. And in case of using sensors made by soft material like silicone, sensors can be used in various situations. So we are developing a tactile sensor with soft materials. As the conventional robot operates in a controlled environment, it is a good model to make robots more available at any circumstance that sensory systems of living things. For example, there are lots of mechanoreceptors that each of them has different roles detecting simulation in side of human skin tissue. By mimicking the mechanoreceptor, a sensory system can be realized more closely to human being. It is known that human obtains roughness information through scanning the surface with fingertips. During that times, subcutaneous mechanoreceptors detect vibration. In the same way, while a robot is scanning a surface of object, a roughness sensor developed detects vibrations generated between contacting two surfaces. In this research, a roughness sensor made by an elastomer was developed and experiment for perception of objects was conducted. We describe means to compare the roughness of objects with a newly developed sensor.

  16. Biologically inspired multi-layered synthetic skin for tactile feedback in prosthetic limbs.

    PubMed

    Osborn, Luke; Nguyen, Harrison; Betthauser, Joseph; Kaliki, Rahul; Thakor, Nitish

    2016-08-01

    The human body offers a template for many state-of-the-art prosthetic devices and sensors. In this work, we present a novel, sensorized synthetic skin that mimics the natural multi-layered nature of mechanoreceptors found in healthy glabrous skin to provide tactile information. The multi-layered sensor is made up of flexible piezoresistive textiles that act as force sensitive resistors (FSRs) to convey tactile information, which are embedded within a silicone rubber to resemble the compliant nature of human skin. The top layer of the synthetic skin is capable of detecting small loads less than 5 N whereas the bottom sensing layer responds reliably to loads over 7 N. Finite element analysis (FEA) of a simplified human fingertip and the synthetic skin was performed. Results suggest similarities in behavior during loading. A natural tactile event is simulated by loading the synthetic skin on a prosthetic limb. Results show the sensors' ability to detect applied loads as well as the ability to simulate neural spiking activity based on the derivative and temporal differences of the sensor response. During the tactile loading, the top sensing layer responded 0.24 s faster than the bottom sensing layer. A synthetic biologically-inspired skin such as this will be useful for enhancing the functionality of prosthetic limbs through tactile feedback.

  17. Assessment of Dementia in Individuals with Dual Sensory Loss: Application of a Tactile Test Battery

    PubMed Central

    Bruhn, Peter; Dammeyer, Jesper

    2018-01-01

    Background/Aims Individuals with dual sensory loss (DSL) are more likely to experience cognitive decline with age than individuals without sensory loss. Other studies have pointed to the challenges in assessing cognitive abilities in individuals with DSL, as most existing instruments rely on use of vision and hearing. The aim of this study was to develop and evaluate a Tactile Test Battery (TTB) for cognitive assessment in individuals with DSL. Method Twenty elderly individuals with DSL, 20 with diagnosed dementia, and 20 without dementia or DSL (controls) completed the following tactile tests developed for the present study: Spatial learning, Spatial recall, Tactile form board, Clock reading, and Naming. The participants with dementia and controls also completed the Mini-Mental State Examination (MMSE). Results Overall, participants with dementia performed significantly worse on the tactile tests than participants with DSL and control participants. No significant differences on the tactile tests were found between participants with DSL and controls. The TTB and MMSE scores correlated significantly. Conclusion The findings from this study of applying tactile tests for cognitive examination in individuals with DSL are promising. They indicate that symptoms of dementia can be differentiated from symptoms related to DSL. PMID:29515619

  18. Age differences in the frontoparietal cognitive control network: Implications for distractibility

    PubMed Central

    Campbell, Karen L.; Grady, Cheryl L.; Ng, Charisa; Hasher, Lynn

    2016-01-01

    Current evidence suggests that older adults have reduced suppression of, and greater implicit memory for, distracting stimuli, due to age-related declines in frontal-based control mechanisms. In this study, we used fMRI to examine age differences in the neural underpinnings of attentional control and their relationship to differences in distractibility and subsequent memory for distraction. Older and younger adults were shown a rapid stream of words or nonwords superimposed on objects and performed a 1-back task on either the letters or the objects, while ignoring the other modality. Older adults were more distracted than younger adults by the overlapping words during the 1-back task, and they subsequently showed more priming for these words on an implicit memory task. A multivariate analysis of the imaging data revealed a set of regions, including the rostral PFC and inferior parietal cortex, that younger adults activated to a greater extent than older adults during the ignore-words condition, and activity in this set of regions was negatively correlated with priming for the distracting words. Functional connectivity analyses using right and left rostral PFC seeds revealed a network of putative control regions, including bilateral parietal cortex, connected to the frontal seeds at rest. Older adults showed reduced functional connectivity within this frontoparietal network, suggesting that their greater distractibility may be due to decreased activity and coherence within a cognitive control network that normally acts to reduce interference from distraction. PMID:22659108

  19. Electro-Active Polymer Based Soft Tactile Interface for Wearable Devices.

    PubMed

    Mun, Seongcheol; Yun, Sungryul; Nam, Saekwang; Park, Seung Koo; Park, Suntak; Park, Bong Je; Lim, Jeong Mook; Kyung, Ki-Uk

    2018-01-01

    This paper reports soft actuator based tactile stimulation interfaces applicable to wearable devices. The soft actuator is prepared by multi-layered accumulation of thin electro-active polymer (EAP) films. The multi-layered actuator is designed to produce electrically-induced convex protrusive deformation, which can be dynamically programmable for wide range of tactile stimuli. The maximum vertical protrusion is and the output force is up to 255 mN. The soft actuators are embedded into the fingertip part of a glove and front part of a forearm band, respectively. We have conducted two kinds of experiments with 15 subjects. Perceived magnitudes of actuator's protrusion and vibrotactile intensity were measured with frequency of 1 Hz and 191 Hz, respectively. Analysis of the user tests shows participants perceive variation of protrusion height at the finger pad and modulation of vibration intensity through the proposed soft actuator based tactile interface.

  20. Computational Intelligence Techniques for Tactile Sensing Systems

    PubMed Central

    Gastaldo, Paolo; Pinna, Luigi; Seminara, Lucia; Valle, Maurizio; Zunino, Rodolfo

    2014-01-01

    Tactile sensing helps robots interact with humans and objects effectively in real environments. Piezoelectric polymer sensors provide the functional building blocks of the robotic electronic skin, mainly thanks to their flexibility and suitability for detecting dynamic contact events and for recognizing the touch modality. The paper focuses on the ability of tactile sensing systems to support the challenging recognition of certain qualities/modalities of touch. The research applies novel computational intelligence techniques and a tensor-based approach for the classification of touch modalities; its main results consist in providing a procedure to enhance system generalization ability and architecture for multi-class recognition applications. An experimental campaign involving 70 participants using three different modalities in touching the upper surface of the sensor array was conducted, and confirmed the validity of the approach. PMID:24949646

  1. Computational intelligence techniques for tactile sensing systems.

    PubMed

    Gastaldo, Paolo; Pinna, Luigi; Seminara, Lucia; Valle, Maurizio; Zunino, Rodolfo

    2014-06-19

    Tactile sensing helps robots interact with humans and objects effectively in real environments. Piezoelectric polymer sensors provide the functional building blocks of the robotic electronic skin, mainly thanks to their flexibility and suitability for detecting dynamic contact events and for recognizing the touch modality. The paper focuses on the ability of tactile sensing systems to support the challenging recognition of certain qualities/modalities of touch. The research applies novel computational intelligence techniques and a tensor-based approach for the classification of touch modalities; its main results consist in providing a procedure to enhance system generalization ability and architecture for multi-class recognition applications. An experimental campaign involving 70 participants using three different modalities in touching the upper surface of the sensor array was conducted, and confirmed the validity of the approach.

  2. A slow-adapting microfluidic-based tactile sensor

    NASA Astrophysics Data System (ADS)

    Tseng, W.-Y.; Fisher, J. S.; Prieto, J. L.; Rinaldi, K.; Alapati, G.; Lee, A. P.

    2009-08-01

    We present a microfluidic-based tactile sensor mimicking the human slow-adapting mechanoreceptor such as Merkel's disc. The sensor is composed of a polyimide (PI)/polydimethylsiloxane (PDMS) multilayer structure. The device uses a hemispherical reservoir filled with electrolyte solution in the PDMS layer, a microchannel in the PI layer and a pair of sensing electrodes below the microchannel as the force transducer. The tactile signal is detected as the impedance change resulting predominantly from the resistance variance due to the electrodes coverage by the 1M NaCl solution and is measured across the electrode pair. The sensor response is linear and the working range is shown to be in the range of 0-1.8 N. The characterization results also demonstrate the sensing of various levels of forces and its long-term signal stability.

  3. Stiffness mapping prostate biopsy samples using a tactile sensor.

    PubMed

    Peng, Qiyu; Omata, Sadao; Peehl, Donna M; Constantinou, Chris E

    2011-01-01

    Previous studies have demonstrated that the stiffness of cancerous cells reflects their pathological stage and progression rates, with increased cancerous cell stiffness associated with increased aggressiveness. Therefore, the elasticity of the cancerous cells has the potential to be used as an indicator of the cancer's aggressiveness. However, the sensitivity and resolution of current palpation and imaging techniques are not sufficient to detect small cancerous tissues. In previous studies, we developed a tactile-based device to map with high resolution the stiffness of a tissue section. The purpose of this study is to evaluate this device using different tissues (BPH, Cancer and PZ) collected from human prostates. The preliminary results show that the tactile device is sensitive enough to tell the differences of the stiffness of different tissues. The results also disclosed the factors (humidity, temperature and tissue degradation) which could dramatically affect the results of stiffness mapping. The tactile technology described in this paper has the potential to help disclose the underlying mechanical mechanisms that lead to increased stiffness in prostate tumors.

  4. Bioinspired active whisker sensor for robotic vibrissal tactile sensing

    NASA Astrophysics Data System (ADS)

    Ju, Feng; Ling, Shih-Fu

    2014-12-01

    A whisker transducer (WT) inspired by rat’s vibrissal tactile perception is proposed based on a transduction matrix model characterizing the electro-mechanical transduction process in both forward and backward directions. It is capable of acting as an actuator to sweep the whisker and simultaneously as a sensor to sense the force, motion, and mechanical impedance at whisker tip. Its validity is confirmed by numerical simulation using a finite element model. A prototype is then fabricated and its transduction matrix is determined by parameter identification. The calibrated WT can accurately sense mechanical impedance which is directly related to stiffness, mass and damping. Subsequent vibrissal tactile sensing of sandpaper texture reveals that the real part of mechanical impedance sensed by WT is correlated with sandpaper roughness. Texture discrimination is successfully achieved by inputting the real part to a k-means clustering algorithm. The mechanical impedance sensing ability as well as other features of the WT such as simultaneous-actuation-and-sensing makes it a good solution to robotic tactile sensing.

  5. The TacTip Family: Soft Optical Tactile Sensors with 3D-Printed Biomimetic Morphologies

    PubMed Central

    Pestell, Nicholas; Cramphorn, Luke; Winstone, Benjamin; Giannaccini, Maria Elena; Rossiter, Jonathan; Lepora, Nathan F.

    2018-01-01

    Abstract Tactile sensing is an essential component in human–robot interaction and object manipulation. Soft sensors allow for safe interaction and improved gripping performance. Here we present the TacTip family of sensors: a range of soft optical tactile sensors with various morphologies fabricated through dual-material 3D printing. All of these sensors are inspired by the same biomimetic design principle: transducing deformation of the sensing surface via movement of pins analogous to the function of intermediate ridges within the human fingertip. The performance of the TacTip, TacTip-GR2, TacTip-M2, and TacCylinder sensors is here evaluated and shown to attain submillimeter accuracy on a rolling cylinder task, representing greater than 10-fold super-resolved acuity. A version of the TacTip sensor has also been open-sourced, enabling other laboratories to adopt it as a platform for tactile sensing and manipulation research. These sensors are suitable for real-world applications in tactile perception, exploration, and manipulation, and will enable further research and innovation in the field of soft tactile sensing. PMID:29297773

  6. The TacTip Family: Soft Optical Tactile Sensors with 3D-Printed Biomimetic Morphologies.

    PubMed

    Ward-Cherrier, Benjamin; Pestell, Nicholas; Cramphorn, Luke; Winstone, Benjamin; Giannaccini, Maria Elena; Rossiter, Jonathan; Lepora, Nathan F

    2018-04-01

    Tactile sensing is an essential component in human-robot interaction and object manipulation. Soft sensors allow for safe interaction and improved gripping performance. Here we present the TacTip family of sensors: a range of soft optical tactile sensors with various morphologies fabricated through dual-material 3D printing. All of these sensors are inspired by the same biomimetic design principle: transducing deformation of the sensing surface via movement of pins analogous to the function of intermediate ridges within the human fingertip. The performance of the TacTip, TacTip-GR2, TacTip-M2, and TacCylinder sensors is here evaluated and shown to attain submillimeter accuracy on a rolling cylinder task, representing greater than 10-fold super-resolved acuity. A version of the TacTip sensor has also been open-sourced, enabling other laboratories to adopt it as a platform for tactile sensing and manipulation research. These sensors are suitable for real-world applications in tactile perception, exploration, and manipulation, and will enable further research and innovation in the field of soft tactile sensing.

  7. Pure associative tactile agnosia for the left hand: clinical and anatomo-functional correlations.

    PubMed

    Veronelli, Laura; Ginex, Valeria; Dinacci, Daria; Cappa, Stefano F; Corbo, Massimo

    2014-09-01

    Associative tactile agnosia (TA) is defined as the inability to associate information about object sensory properties derived through tactile modality with previously acquired knowledge about object identity. The impairment is often described after a lesion involving the parietal cortex (Caselli, 1997; Platz, 1996). We report the case of SA, a right-handed 61-year-old man affected by first ever right hemispheric hemorrhagic stroke. The neurological examination was normal, excluding major somaesthetic and motor impairment; a brain magnetic resonance imaging (MRI) confirmed the presence of a right subacute hemorrhagic lesion limited to the post-central and supra-marginal gyri. A comprehensive neuropsychological evaluation detected a selective inability to name objects when handled with the left hand in the absence of other cognitive deficits. A series of experiments were conducted in order to assess each stage of tactile recognition processing using the same stimulus sets: materials, 3D geometrical shapes, real objects and letters. SA and seven matched controls underwent the same experimental tasks during four sessions in consecutive days. Tactile discrimination, recognition, pantomime, drawing after haptic exploration out of vision and tactile-visual matching abilities were assessed. In addition, we looked for the presence of a supra-modal impairment of spatial perception and of specific difficulties in programming exploratory movements during recognition. Tactile discrimination was intact for all the stimuli tested. In contrast, SA was able neither to recognize nor to pantomime real objects manipulated with the left hand out of vision, while he identified them with the right hand without hesitations. Tactile-visual matching was intact. Furthermore, SA was able to grossly reproduce the global shape in drawings but failed to extract details of objects after left-hand manipulation, and he could not identify objects after looking at his own drawings. This case

  8. Tactile Data Entry for Extravehicular Activity

    NASA Technical Reports Server (NTRS)

    Adams, Richard J.; Olowin, Aaron B.; Hannaford, Blake; Sands, O Scott

    2012-01-01

    In the task-saturated environment of extravehicular activity (EVA), an astronaut's ability to leverage suit-integrated information systems is limited by a lack of options for data entry. In particular, bulky gloves inhibit the ability to interact with standard computing interfaces such as a mouse or keyboard. This paper presents the results of a preliminary investigation into a system that permits the space suit gloves themselves to be used as data entry devices. Hand motion tracking is combined with simple finger gesture recognition to enable use of a virtual keyboard, while tactile feedback provides touch-based context to the graphical user interface (GUI) and positive confirmation of keystroke events. In human subject trials, conducted with twenty participants using a prototype system, participants entered text significantly faster with tactile feedback than without (p = 0.02). The results support incorporation of vibrotactile information in a future system that will enable full touch typing and general mouse interactions using instrumented EVA gloves.

  9. The effects of an oral distraction on cattle during a painful procedure

    PubMed Central

    Aitken, Brooke L.; Stookey, Joseph M.; Noble, Scott; Watts, Jon; Finlay, Don

    2013-01-01

    An oral distraction was investigated as a way to reduce struggle and heart rate of beef cattle undergoing freeze branding. Oral distraction reduced the struggle of steers, regardless of branding treatment. No effect on heart rate was found. Distractions may provide a way to reduce struggle by animals during restraint. PMID:24155450

  10. Analysis of naturalistic driving videos of fleet services drivers to estimate driver error and potentially distracting behaviors as risk factors for rear-end versus angle crashes.

    PubMed

    Harland, Karisa K; Carney, Cher; McGehee, Daniel

    2016-07-03

    The objective of this study was to estimate the prevalence and odds of fleet driver errors and potentially distracting behaviors just prior to rear-end versus angle crashes. Analysis of naturalistic driving videos among fleet services drivers for errors and potentially distracting behaviors occurring in the 6 s before crash impact. Categorical variables were examined using the Pearson's chi-square test, and continuous variables, such as eyes-off-road time, were compared using the Student's t-test. Multivariable logistic regression was used to estimate the odds of a driver error or potentially distracting behavior being present in the seconds before rear-end versus angle crashes. Of the 229 crashes analyzed, 101 (44%) were rear-end and 128 (56%) were angle crashes. Driver age, gender, and presence of passengers did not differ significantly by crash type. Over 95% of rear-end crashes involved inadequate surveillance compared to only 52% of angle crashes (P < .0001). Almost 65% of rear-end crashes involved a potentially distracting driver behavior, whereas less than 40% of angle crashes involved these behaviors (P < .01). On average, drivers spent 4.4 s with their eyes off the road while operating or manipulating their cell phone. Drivers in rear-end crashes were at 3.06 (95% confidence interval [CI], 1.73-5.44) times adjusted higher odds of being potentially distracted than those in angle crashes. Fleet driver driving errors and potentially distracting behaviors are frequent. This analysis provides data to inform safe driving interventions for fleet services drivers. Further research is needed in effective interventions to reduce the likelihood of drivers' distracting behaviors and errors that may potentially reducing crashes.

  11. Evaluation of cranial bone transport distraction with and without adipose grafting.

    PubMed

    Koch, Felix P; Yuhasz, Mikell M; Travieso, Rob; Wong, Kenneth; Clune, James; Zhuang, Zhen W; Van Houten, Joshua; Steinbacher, Derek M

    2014-05-01

    Transport distraction osteogenesis (DO) can be used to autologously reconstitute calvarial defects. The purpose of this study is to histomorphologically interrogate osteogenic formation during cranial transport distraction using a novel device. We also evaluate the effect of fat grafting on the regenerate and soft-tissue stability during distraction. This study was approved by Yale IACUC. Ten male New Zealand white rabbits (3 mo; 3.5 kg) were used (8 treatment, 2 control). A 16 × 16 mm defect was created abutted by a 10 × 16 mm transport disc. The device was fixated anterioposteriorly. Four animals were fat-grafted using 2 mL of subdermal intrascapular fat deposited along the distraction site. Latency (1 d), active distraction (12-14 d) (1.5 mm/d), and consolidation (4 wk) followed. Calcein and xylene orange fluorochromes were injected subcutaneously during and post-distraction to mark sites of bone formation. Following sacrifice, osteogenesis was assessed using microCT, histology, and fluorescence. Treatment animals demonstrated regenerate bone between distracted segments on microCT. MicroCT analysis of non-fat-grafted and fat-grafted animals revealed a mean density of 2271.95 mgHA/ccm and 2254.27 mgHA/ccm (P = 0.967), respectively, and defect bone versus total volume (BV/TV) of 0.0999 and 0.0766 (P = 0.5979), respectively. Controls had minimal reossification. Histologically, mean densities measured 43.63% and 8.19%, respectively. Fluorescence revealed ossification from the callus as well as from dura and periosteum in the cranial defect. Transport distraction is effective to reconstruct critically sized rabbit calvarial defects. Regenerate bone arises predominantly from the callus with contribution from surrounding dura and periosteum. Adipose grafting is well tolerated but does not enhance osseous regeneration.

  12. The Impact of Operating Room Distractions on Stress, Workload, and Teamwork.

    PubMed

    Wheelock, Ana; Suliman, Amna; Wharton, Rupert; Babu, E D; Hull, Louise; Vincent, Charles; Sevdalis, Nick; Arora, Sonal

    2015-06-01

    To investigate whether distractions in the operating room (OR) are associated with higher mental workload and stress, and poorer teamwork among OR personnel. Engaging in multiple tasks can affect performance. There is little research on the effect of distractions on surgical team members' behavior and cognitive processes. Ninety general surgery cases were observed in real time. Cases were assessed by a surgeon and a behavioral scientist using 4 validated tools: OR Distractions Assessment Form, the Observational Teamwork Assessment for Surgery tool, NASA-Task Load Index, and short form of the State Trait Anxiety Inventory. Analysis of variance was performed to evaluate significant differences between teamwork, workload, and stress level among team members. Correlations (Pearson r) were computed to evaluate associations between variables. The most prevalent distractions were those initiated by external staff, followed by case-irrelevant conversations. Case-irrelevant conversations were associated with poorer team performance. Irrelevant conversations initiated by surgeons were associated with lower teamwork in surgeons (across team skills: r = -0.44 to -0.58, P < 0.05 to 0.01) and anesthesiologists (r = -0.38 and r = -0.40, for coordination and leadership; P < 0.05). Equipment-related distractions correlated with higher stress (r = 0.48, P < 0.05) and lower teamwork (across team skills: r = -0.42 to -0.50, P < 0.05) in nurses. Acoustic distractions correlated with higher stress in surgeons (r = 0.32, P < 0.05) and higher workload in anesthesiologists (r = 0.30, P < 0.05). Although some distractions may be inevitable in the OR, they can also be detrimental to the team. A deeper understanding of the effect of distractions on teams and their outcomes can lead to targeted quality improvement.

  13. Associations of distraction involvement and age with driver injury severities.

    PubMed

    Donmez, Birsen; Liu, Zishu

    2015-02-01

    This paper investigates the associations between the severity of injuries sustained by a driver who is involved in a two-vehicle crash, the existence and type of driver distraction as well as driver's age. Few studies investigated distraction as it relates to injury severity. Moreover, these studies did not consider driver age which is a significant factor related to driving behavior and the ability to respond in a crash situation. An ordered logit model was built to predict injury severity sustained by drivers using data from the U.S. National Automotive Sampling System's General Estimates System (2003 to 2008). Various factors (e.g., weather, gender, and speeding) were statistically controlled for, but the main focus was on the interaction of driver age and distraction type. The trends observed for young and mid-age drivers were similar. For these age groups, dialing or texting on the cell phone, passengers, and in-vehicle sources resulted in an increase in a likelihood of more severe injuries. Talking on the cell phone had a similar effect for younger drivers but was not significant for mid-age drivers. Inattention and distractions outside the vehicle decreased the odds of severe injuries. For older drivers, the highest odds of severe injuries were observed with dialing or texting on a cell phone, followed by in-vehicle sources and talking on the cell phone. All these sources were associated with an increased likelihood of injury severity. Similar to young and mid-age drivers, distractions outside the vehicle decreased the odds of severe injuries. Other distraction types did not have a significant effect for the older age group. The results support previous literature and extend our understanding of crash injury severity. The findings have implications for policy making and the design of distraction mitigation systems. Copyright © 2014 National Safety Council and Elsevier Ltd. All rights reserved.

  14. [Maxillary distraction complications in cleft patients].

    PubMed

    Jeblaoui, Y; Morand, B; Brix, M; Lebeau, J; Bettega, G

    2008-09-01

    Cleft lip and palate (CLP) patients often present with a class III malocclusion in connection with a three dimensional maxillary hypoplasia. Twenty-five to 60% of these patients require a maxillary advancement. Two solutions are possible: orthognathic surgery and maxillary distraction. The purpose of this study was to evaluate the complications of the maxillary distraction in CLP patients. Data was collected from the records of patients treated at our Surgery Unit between 2000 and 2007. Among the eight patients (four male and four female), five presented a bilateral CLP, two a unilateral CLP and one a unilateral cleft lip associated to a soft palate cleft. The average age at surgery was 17 years old. All had a Le Fort I osteotomy with a pterygomaxillary disjunction. The first two patients had external distractors and the six following internal ones. After a seven-day latency, activation was led to the rate of 1mm per day twice. The period of consolidation was four months on average. The maxillary advancement varied between 7 and 19 mm with an average of 12.6mm. The average follow-up was four years. We encountered difficulties and/or complications in seven patients: one intraoperatively haemorrhage, one avulsion of a tooth fixed at the pterygoid process during the osteotomy, three device failures, two cases of significant pains during activation, one dissociation of the dental anchorage of an external system, two labial ulcerations and one maxillary sinusitis by migration of the 18. Difficulties of maxillary distraction in CLP patients are very frequent. The majority is related to the distractors and did not interfere with the final result. But this frequency must be taken into account in the indication and in the choice of the material. Two types of complications can occur during distraction: those related to the osteotomy and those related to the material. The complications related to the osteotomy are in connection with the cicatricial ground of the CLP. They are

  15. Treatment of maxillary cleft palate: Distraction osteogenesis vs. orthognathic surgery

    PubMed Central

    Rachmiel, Adi; Even-Almos, Michal; Aizenbud, Dror

    2012-01-01

    Purpose: The purpose of this paper is to compare the treatment of hypoplastic, retruded maxillary cleft palate using distraction osteogenesis vs. orthognathic surgery in terms of stability and relapse, growth after distraction and soft tissue profile changes. Materials and Methods: The cleft patients showed anteroposterior maxillary hypoplasia with class III malocclusion and negative overjet resulting in a concave profile according to preoperative cephalometric measurements, dental relationship, and soft tissue analysis. The patients were divided in two groups of treatment : S0 eventeen were treated by orthognathic Le Fort I osteotomy fixed with four mini plates and 2 mm screws, and 19 were treated by maxillary distraction osteogenesis with rigid extraoral devices (RED) connected after a Le Fort I osteotomy. The rate of distraction was 1 mm per day to achieve Class I occlusion with slight overcorrection and to create facial profile convexity. Following a 10 week latency period the distraction devices were removed. Results: In the RED group the maxilla was advanced an average of 15.80 mm. The occlusion changed from class III to class I. The profile of the face changed from concave to convex. At a 1-year follow up the results were stable. The mean orthognathic movement was 8.4 mm. Conclusion: In mild maxillary deficiency a one stage orthognathic surgery is preferable. However, in patients requiring moderate to large advancements with significant structural deficiencies of the maxilla or in growing patients the distraction technique is preferred. PMID:23483803

  16. Now You Feel both: Galvanic Vestibular Stimulation Induces Lasting Improvements in the Rehabilitation of Chronic Tactile Extinction

    PubMed Central

    Schmidt, Lena; Utz, Kathrin S.; Depper, Lena; Adams, Michaela; Schaadt, Anna-Katharina; Reinhart, Stefan; Kerkhoff, Georg

    2013-01-01

    Tactile extinction is frequent, debilitating, and often persistent after brain damage. Currently, there is no treatment available for this disorder. In two previous case studies we showed an influence of galvanic vestibular stimulation (GVS) on tactile extinction. Here, we evaluated in further patients the immediate and lasting effects of GVS on tactile extinction. GVS is known to induce polarity-specific changes in cerebral excitability in the vestibular cortices and adjacent cortical areas. Tactile extinction was examined with the Quality Extinction Test (QET) where subjects have to discriminate six different tactile fabrics in bilateral, double simultaneous stimulations on their dorsum of hands with identical or different tactile fabrics. Twelve patients with stable left-sided tactile extinction after unilateral right-hemisphere lesions were divided into two groups. The GVS group (N = 6) performed the QET under six different experimental conditions (two Baselines, Sham-GVS, left-cathodal/right-anodal GVS, right-cathodal/left-anodal GVS, and a Follow-up test). The second group of patients with left-sided extinction (N = 6) performed the QET six times repetitively, but without receiving GVS (control group). Both right-cathodal/left-anodal as well as left-cathodal/right-anodal GVS (mean: 0.7 mA) improved tactile identification of identical and different stimuli in the experimental group. These results show a generic effect of GVS on tactile extinction, but not in a polarity-specific way. These observed effects persisted at follow-up. Sham-GVS had no significant effect on extinction. In the control group, no significant improvements were seen in the QET after the six measurements of the QET, thus ruling out test repetition effects. In conclusion, GVS improved bodily awareness permanently for the contralesional body side in patients with tactile extinction and thus offers a novel treatment option for these patients. PMID:23519604

  17. An examination of driver distraction as recorded in NHTSA databases

    DOT National Transportation Integrated Search

    2009-09-01

    The purpose of this research note is to provide fatality, injury, on-scene crash investigation, and survey data associated with distracted driving and to summarize recent data from NHTSA and other DOT modes pertaining to distracted-driving crashes.

  18. Technology-related distracted walking behaviours in Manhattan's most dangerous intersections.

    PubMed

    Basch, Corey H; Ethan, Danna; Rajan, Sonali; Basch, Charles E

    2014-10-01

    Use of mobile devices has been cited as a distraction while driving, and more recently, among pedestrians crossing urban streets. In 2010, over half of New York City traffic fatalities were pedestrians. The aim of this study was to estimate the prevalence of distracted walking due to pedestrians' use of headphones, mobile phones, or both. Data were gathered by direct observations at the 10 intersections in Manhattan with the highest frequency of pedestrian-motor vehicle collisions. More than 1 in 4 of the >3500 pedestrians observed were distracted by mobile electronic devices while crossing during the 'walk' (28.8%) and 'don't walk' (26.3%) signals. Poisson regression analyses established there was a significant difference in individuals talking on a mobile device during the 'walk' signal versus the 'don't walk' signal; however, no other significant differences in other distracted walking behaviours were observed. This study contributes to the emerging literature on distracted walking behaviour by pedestrians in busy urban areas and can help to inform pedestrian-focused safety efforts. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  19. Safety implications of providing real-time feedback to distracted drivers.

    PubMed

    Donmez, Birsen; Boyle, Linda Ng; Lee, John D

    2007-05-01

    A driving simulator study was conducted to assess whether real-time feedback on a driver's state can influence the driver's interaction with in-vehicle information systems (IVIS). Previous studies have shown that IVIS tasks can undermine driver safety by increasing driver distraction. Thus, mitigating driver distraction using a feedback mechanism appears promising. This study was designed to test real-time feedback that alerts drivers based on their off-road eye glances. Feedback was displayed in two display locations (vehicle-centered, and IVIS-centered) to 16 young and 13 middle-aged drivers. Distraction was observed as problematic for both age groups with delayed responses to a lead vehicle-braking event as indicated by delayed accelerator releases. Significant benefits were not observed for braking and steering behavior for this experiment, but there was a significant change in drivers' interaction with IVIS. When given feedback on their distracted state, drivers looked at the in-vehicle display less frequently regardless of where feedback was displayed in the vehicle. This indicates that real-time feedback based on the driver state can positively alter driver's engagement in distracting activities, helping them attend better to the roadway.

  20. 'Sorry, I meant the patient's left side': impact of distraction on left-right discrimination.

    PubMed

    McKinley, John; Dempster, Martin; Gormley, Gerard J

    2015-04-01

    Medical students can have difficulty in distinguishing left from right. Many infamous medical errors have occurred when a procedure has been performed on the wrong side, such as in the removal of the wrong kidney. Clinicians encounter many distractions during their work. There is limited information on how these affect performance. Using a neuropsychological paradigm, we aim to elucidate the impacts of different types of distraction on left-right (LR) discrimination ability. Medical students were recruited to a study with four arms: (i) control arm (no distraction); (ii) auditory distraction arm (continuous ambient ward noise); (iii) cognitive distraction arm (interruptions with clinical cognitive tasks), and (iv) auditory and cognitive distraction arm. Participants' LR discrimination ability was measured using the validated Bergen Left-Right Discrimination Test (BLRDT). Multivariate analysis of variance was used to analyse the impacts of the different forms of distraction on participants' performance on the BLRDT. Additional analyses looked at effects of demographics on performance and correlated participants' self-perceived LR discrimination ability and their actual performance. A total of 234 students were recruited. Cognitive distraction had a greater negative impact on BLRDT performance than auditory distraction. Combined auditory and cognitive distraction had a negative impact on performance, but only in the most difficult LR task was this negative impact found to be significantly greater than that of cognitive distraction alone. There was a significant medium-sized correlation between perceived LR discrimination ability and actual overall BLRDT performance. Distraction has a significant impact on performance and multifaceted approaches are required to reduce LR errors. Educationally, greater emphasis on the linking of theory and clinical application is required to support patient safety and human factor training in medical school curricula. Distraction has

  1. Tactile feedback to the palm using arbitrarily shaped DEA

    NASA Astrophysics Data System (ADS)

    Mößinger, Holger; Haus, Henry; Kauer, Michaela; Schlaak, Helmut F.

    2014-03-01

    Tactile stimulation enhances user experience and efficiency in human machine interaction by providing information via another sensory channel to the human brain. DEA as tactile interfaces have been in the focus of research in recent years. Examples are (vibro-) tactile keyboards or Braille displays. These applications of DEA focus mainly on interfacing with the user's fingers or fingertips only - demonstrating the high spatial resolution achievable with DEA. Besides providing a high resolution, the flexibility of DEA also allows designing free form surfaces equipped with single actuators or actuator matrices which can be fitted to the surface of the human skin. The actuators can then be used to provide tactile stimuli to different areas of the body, not to the fingertips only. Utilizing and demonstrating this flexibility we designed a free form DEA pad shaped to fit into the inside of the human palm. This pad consists of four single actuators which can provide e.g. directional information such as left, right, up and down. To demonstrate the value of such free form actuators we manufactured a PC-mouse using 3d printing processes. The actuator pad is mounted on the back of the mouse, resting against the palm while operating it. Software on the PC allows control of the vibration patterns displayed by the actuators. This allows helping the user by raising attention to certain directions or by discriminating between different modes like "pick" or "manipulate". Results of first tests of the device show an improved user experience while operating the PC mouse.

  2. Mechanisms underlying a thalamocortical transformation during active tactile sensation

    PubMed Central

    Gutnisky, Diego Adrian; Yu, Jianing; Hires, Samuel Andrew; To, Minh-Son; Svoboda, Karel

    2017-01-01

    During active somatosensation, neural signals expected from movement of the sensors are suppressed in the cortex, whereas information related to touch is enhanced. This tactile suppression underlies low-noise encoding of relevant tactile features and the brain’s ability to make fine tactile discriminations. Layer (L) 4 excitatory neurons in the barrel cortex, the major target of the somatosensory thalamus (VPM), respond to touch, but have low spike rates and low sensitivity to the movement of whiskers. Most neurons in VPM respond to touch and also show an increase in spike rate with whisker movement. Therefore, signals related to self-movement are suppressed in L4. Fast-spiking (FS) interneurons in L4 show similar dynamics to VPM neurons. Stimulation of halorhodopsin in FS interneurons causes a reduction in FS neuron activity and an increase in L4 excitatory neuron activity. This decrease of activity of L4 FS neurons contradicts the "paradoxical effect" predicted in networks stabilized by inhibition and in strongly-coupled networks. To explain these observations, we constructed a model of the L4 circuit, with connectivity constrained by in vitro measurements. The model explores the various synaptic conductance strengths for which L4 FS neurons actively suppress baseline and movement-related activity in layer 4 excitatory neurons. Feedforward inhibition, in concert with recurrent intracortical circuitry, produces tactile suppression. Synaptic delays in feedforward inhibition allow transmission of temporally brief volleys of activity associated with touch. Our model provides a mechanistic explanation of a behavior-related computation implemented by the thalamocortical circuit. PMID:28591219

  3. An Extreme Learning Machine-Based Neuromorphic Tactile Sensing System for Texture Recognition.

    PubMed

    Rasouli, Mahdi; Chen, Yi; Basu, Arindam; Kukreja, Sunil L; Thakor, Nitish V

    2018-04-01

    Despite significant advances in computational algorithms and development of tactile sensors, artificial tactile sensing is strikingly less efficient and capable than the human tactile perception. Inspired by efficiency of biological systems, we aim to develop a neuromorphic system for tactile pattern recognition. We particularly target texture recognition as it is one of the most necessary and challenging tasks for artificial sensory systems. Our system consists of a piezoresistive fabric material as the sensor to emulate skin, an interface that produces spike patterns to mimic neural signals from mechanoreceptors, and an extreme learning machine (ELM) chip to analyze spiking activity. Benefiting from intrinsic advantages of biologically inspired event-driven systems and massively parallel and energy-efficient processing capabilities of the ELM chip, the proposed architecture offers a fast and energy-efficient alternative for processing tactile information. Moreover, it provides the opportunity for the development of low-cost tactile modules for large-area applications by integration of sensors and processing circuits. We demonstrate the recognition capability of our system in a texture discrimination task, where it achieves a classification accuracy of 92% for categorization of ten graded textures. Our results confirm that there exists a tradeoff between response time and classification accuracy (and information transfer rate). A faster decision can be achieved at early time steps or by using a shorter time window. This, however, results in deterioration of the classification accuracy and information transfer rate. We further observe that there exists a tradeoff between the classification accuracy and the input spike rate (and thus energy consumption). Our work substantiates the importance of development of efficient sparse codes for encoding sensory data to improve the energy efficiency. These results have a significance for a wide range of wearable, robotic

  4. Knee joint distraction compared with high tibial osteotomy: a randomized controlled trial.

    PubMed

    van der Woude, J A D; Wiegant, K; van Heerwaarden, R J; Spruijt, S; van Roermund, P M; Custers, R J H; Mastbergen, S C; Lafeber, F P J G

    2017-03-01

    Both, knee joint distraction as a relatively new approach and valgus-producing opening-wedge high tibial osteotomy (HTO), are knee-preserving treatments for knee osteoarthritis (OA). The efficacy of knee joint distraction compared to HTO has not been reported. Sixty-nine patients with medial knee joint OA with a varus axis deviation of <10° were randomized to either knee joint distraction (n = 23) or HTO (n = 46). Questionnaires were assessed at baseline and 3, 6, and 12 months. Joint space width (JSW) as a surrogate measure for cartilage thickness was determined on standardized semi-flexed radiographs at baseline and 1-year follow-up. All patient-reported outcome measures (PROMS) improved significantly over 1 year (at 1 year p < 0.02) in both groups. At 1 year, the HTO group showed slightly greater improvement in 4 of the 16 PROMS (p < 0.05). The minimum medial compartment JSW increased 0.8 ± 1.0 mm in the knee joint distraction group (p = 0.001) and 0.4 ± 0.5 mm in the HTO group (p < 0.001), with minimum JSW improvement in favour of knee joint distraction (p = 0.05). The lateral compartment showed a small increase in the knee joint distraction group and a small decrease in the HTO group, leading to a significant increase in mean JSW for knee joint distraction only (p < 0.02). Cartilaginous repair activity, as indicated by JSW, and clinical outcome improvement occurred with both, knee joint distraction and HTO. These findings suggest that knee joint distraction may be an alternative therapy for medial compartmental OA with a limited mechanical leg malalignment. Randomized controlled trial, Level I.

  5. Angioplasty balloon catheters used for distraction of the ankle joint.

    PubMed

    Sartoretti, C; Sartoretti-Schefer, S; Duff, C; Buchmann, P

    1996-02-01

    Arthroscopy of the ankle joint is now routinely performed in diagnostic and therapeutic interventions but is still a demanding and difficult operative procedure in this very small and tight joint. Arthroscopy can be facilitated by a sufficient distraction that gives a better overview of the joint space. However, it is still a matter of debate how to obtain the adequate distraction. Distention by manual strength as well as by the help of a technical device have been proposed. We report our experience with distraction of the ankle joint by the help of one or two intraarticularily located and secondarily insufflated angioplasty balloon catheters that are routinely used in interventional radiology. These special catheters allow a careful and controlled distention of the joint with a fixed space of distraction and, according to our limited experience, without any morbidity.

  6. Artificial Roughness Encoding with a Bio-inspired MEMS- based Tactile Sensor Array

    PubMed Central

    Oddo, Calogero Maria; Beccai, Lucia; Felder, Martin; Giovacchini, Francesco; Carrozza, Maria Chiara

    2009-01-01

    A compliant 2×2 tactile sensor array was developed and investigated for roughness encoding. State of the art cross shape 3D MEMS sensors were integrated with polymeric packaging providing in total 16 sensitive elements to external mechanical stimuli in an area of about 20 mm2, similarly to the SA1 innervation density in humans. Experimental analysis of the bio-inspired tactile sensor array was performed by using ridged surfaces, with spatial periods from 2.6 mm to 4.1 mm, which were indented with regulated 1N normal force and stroked at constant sliding velocity from 15 mm/s to 48 mm/s. A repeatable and expected frequency shift of the sensor outputs depending on the applied stimulus and on its scanning velocity was observed between 3.66 Hz and 18.46 Hz with an overall maximum error of 1.7%. The tactile sensor could also perform contact imaging during static stimulus indentation. The experiments demonstrated the suitability of this approach for the design of a roughness encoding tactile sensor for an artificial fingerpad. PMID:22412304

  7. Functionalization of Tactile Sensation for Robot Based on Haptograph and Modal Decomposition

    NASA Astrophysics Data System (ADS)

    Yokokura, Yuki; Katsura, Seiichiro; Ohishi, Kiyoshi

    In the real world, robots should be able to recognize the environment in order to be of help to humans. A video camera and a laser range finder are devices that can help robots recognize the environment. However, these devices cannot obtain tactile information from environments. Future human-assisting-robots should have the ability to recognize haptic signals, and a disturbance observer can possibly be used to provide the robot with this ability. In this study, a disturbance observer is employed in a mobile robot to functionalize the tactile sensation. This paper proposes a method that involves the use of haptograph and modal decomposition for the haptic recognition of road environments. The haptograph presents a graphic view of the tactile information. It is possible to classify road conditions intuitively. The robot controller is designed by considering the decoupled modal coordinate system, which consists of translational and rotational modes. Modal decomposition is performed by using a quarry matrix. Once the robot is provided with the ability to recognize tactile sensations, its usefulness to humans will increase.

  8. A flexible tactile-feedback touch screen using transparent ferroelectric polymer film vibrators

    NASA Astrophysics Data System (ADS)

    Ju, Woo-Eon; Moon, Yong-Ju; Park, Cheon-Ho; Choi, Seung Tae

    2014-07-01

    To provide tactile feedback on flexible touch screens, transparent relaxor ferroelectric polymer film vibrators were designed and fabricated in this study. The film vibrator can be integrated underneath a transparent cover film or glass, and can also produce acoustic waves that cause a tactile sensation on human fingertips. Poly(vinylidene fluoride-trifluoroethylene-chlorotrifluoroethylene) [P(VDF-TrFE-CTFE)] polymer was used as the relaxor ferroelectric polymer because it produces a large strain under applied electric fields, shows a fast response, and has excellent optical transparency. The natural frequency of this tactile-feedback touch screen was designed to be around 200-240 Hz, at which the haptic perception of human fingertips is the most sensitive; therefore, the resonance of the touch screen at its natural frequency provides maximum haptic sensation. A multilayered relaxor ferroelectric polymer film vibrator was also demonstrated to provide the same vibration power at reduced voltage. The flexible P(VDF-TrFE-CTFE) film vibrators developed in this study are expected to provide tactile sensation not only in large-area flat panel displays, but also in flexible displays and touch screens.

  9. Resisting distraction and response inhibition trigger similar enhancements of future performance.

    PubMed

    Bissett, Patrick G; Grant, Lauren D; Weissman, Daniel H

    2017-10-01

    Resisting distraction and response inhibition are crucial aspects of cognitive control. Interestingly, each of these abilities transiently improves just after it is utilized. Competing views differ, however, as to whether utilizing either of these abilities (e.g., resisting distraction) enhances future performance involving the other ability (e.g., response inhibition). To distinguish between these views, we combined a Stroop-like task that requires resisting distraction with a restraint variant of the stop-signal task that requires response inhibition. We observed similar sequential-trial effects (i.e., performance enhancements) following trials in which participants (a) resisted distraction (i.e., incongruent go trials) and (b) inhibited a response (i.e., congruent stop trials). First, the congruency effect in go trials, which indexes overall distractibility, was smaller after both incongruent go trials and congruent stop trials than it was after congruent go trials. Second, stop failures were less frequent after both incongruent go trials and congruent stop trials than after congruent go trials. A control experiment ruled out the possibility that perceptual conflict or surprise engendered by occasional stop signals triggers sequential-trial effects independent of stopping. Thus, our findings support a novel, integrated view in which resisting distraction and response inhibition trigger similar sequential enhancements of future performance. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Coping and Psychological Adjustment among Mothers of Children with ASD: An Accelerated Longitudinal Study

    ERIC Educational Resources Information Center

    Benson, Paul R.

    2014-01-01

    Utilizing a cohort sequential design and multilevel modeling on a sample of 113 mothers, the effects of four coping strategies (engagement, disengagement, distraction, and cognitive reframing) on multiple measures of maternal adjustment were assessed over a 7 years period when children with autism spectrum disorders in the study were approximately…

  11. Distracted Driving Raises Crash Risk

    MedlinePlus

    ... Send us your comments Video technology and in-vehicle sensors showed that distracted driving, especially among new ... habits of both novice teen and experienced drivers. Vehicles were equipped with 4 cameras that recorded video ...

  12. Symbol recognition produced by points of tactile stimulation: the illusion of linear continuity.

    PubMed

    Gonzales, G R

    1996-11-01

    To determine whether tactile receptive communication is possible through the use of a mechanical device that produces the phi phenomenon on the body surface. Twenty-six subjects (11 blind and 15 sighted participants) were tested with use of a tactile communication device (TCD) that produces an illusion of linear continuity forming numbers on the dorsal aspect of the wrist. Recognition of a number or number set was the goal. A TCD with protruding and vibrating solenoids produced sequentially delivered points of cutaneous stimulation along a pattern resembling numbers and created the illusion of dragging a vibrating stylet to form numbers, similar to what might be felt by testing for graphesthesia. Blind subjects recognized numbers with fewer trials than did sighted subjects, although all subjects were able to recognize all the numbers produced by the TCD. Subjects who had been blind since birth and had no prior tactile exposure to numbers were able to draw the numbers after experiencing them delivered by the TCD even though they did not recognize their meaning. The phi phenomenon is probably responsible for the illusion of continuous lines in the shape of numbers as produced by the TCD. This tactile illusion could potentially be used for more complex tactile communications such as letters and words.

  13. Differences in Early Stages of Tactile ERP Temporal Sequence (P100) in Cortical Organization during Passive Tactile Stimulation in Children with Blindness and Controls.

    PubMed

    Ortiz Alonso, Tomás; Santos, Juan Matías; Ortiz Terán, Laura; Borrego Hernández, Mayelin; Poch Broto, Joaquín; de Erausquin, Gabriel Alejandro

    2015-01-01

    Compared to their seeing counterparts, people with blindness have a greater tactile capacity. Differences in the physiology of object recognition between people with blindness and seeing people have been well documented, but not when tactile stimuli require semantic processing. We used a passive vibrotactile device to focus on the differences in spatial brain processing evaluated with event related potentials (ERP) in children with blindness (n = 12) vs. normally seeing children (n = 12), when learning a simple spatial task (lines with different orientations) or a task involving recognition of letters, to describe the early stages of its temporal sequence (from 80 to 220 msec) and to search for evidence of multi-modal cortical organization. We analysed the P100 of the ERP. Children with blindness showed earlier latencies for cognitive (perceptual) event related potentials, shorter reaction times, and (paradoxically) worse ability to identify the spatial direction of the stimulus. On the other hand, they are equally proficient in recognizing stimuli with semantic content (letters). The last observation is consistent with the role of P100 on somatosensory-based recognition of complex forms. The cortical differences between seeing control and blind groups, during spatial tactile discrimination, are associated with activation in visual pathway (occipital) and task-related association (temporal and frontal) areas. The present results show that early processing of tactile stimulation conveying cross modal information differs in children with blindness or with normal vision.

  14. Differences in Early Stages of Tactile ERP Temporal Sequence (P100) in Cortical Organization during Passive Tactile Stimulation in Children with Blindness and Controls

    PubMed Central

    Ortiz Alonso, Tomás; Santos, Juan Matías; Ortiz Terán, Laura; Borrego Hernández, Mayelin; Poch Broto, Joaquín; de Erausquin, Gabriel Alejandro

    2015-01-01

    Compared to their seeing counterparts, people with blindness have a greater tactile capacity. Differences in the physiology of object recognition between people with blindness and seeing people have been well documented, but not when tactile stimuli require semantic processing. We used a passive vibrotactile device to focus on the differences in spatial brain processing evaluated with event related potentials (ERP) in children with blindness (n = 12) vs. normally seeing children (n = 12), when learning a simple spatial task (lines with different orientations) or a task involving recognition of letters, to describe the early stages of its temporal sequence (from 80 to 220 msec) and to search for evidence of multi-modal cortical organization. We analysed the P100 of the ERP. Children with blindness showed earlier latencies for cognitive (perceptual) event related potentials, shorter reaction times, and (paradoxically) worse ability to identify the spatial direction of the stimulus. On the other hand, they are equally proficient in recognizing stimuli with semantic content (letters). The last observation is consistent with the role of P100 on somatosensory-based recognition of complex forms. The cortical differences between seeing control and blind groups, during spatial tactile discrimination, are associated with activation in visual pathway (occipital) and task-related association (temporal and frontal) areas. The present results show that early processing of tactile stimulation conveying cross modal information differs in children with blindness or with normal vision. PMID:26225827

  15. Educating Idaho Teenage Drivers of the Dangers of Distracted Driving

    DOT National Transportation Integrated Search

    2017-08-01

    The objective of this research project efforts are: 1) to develop an interactive driver-distracted presentation that can be used at different high schools in Idaho to educate teenage drivers about the danger of distracted driving, 2) to test the effe...

  16. Treatment of post-traumatic elbow deformities in children with the Ilizarov distraction osteogenesis technique.

    PubMed

    Özkan, Cenk; Deveci, Mehmet Ali; Tekin, Mustafa; Biçer, Ömer Sunkar; Gökçe, Kadir; Gülşen, Mahir

    2017-01-01

    The present study assessed functional and radiographic outcomes of distraction osteogenesis treatment of post-traumatic elbow deformities in children. Eight children were treated between 2008 and 2013 for post-traumatic elbow deformities using distraction osteogenesis. Mean age at time of operation was 10.9 years. Six patients had varus and 2 had valgus deformity. Magnitude of correction, fixator index, complications, carrying angle, and elbow range of motion were assessed. Functional results were graded according to protocol of Bellemore et al. Mean follow-up was 43 months. Mean preoperative varus deformity in 6 patients was 29.2° and valgus deformity in 2 patients was 28.5°. Preoperative flexion and extension of elbow were 123.8° and -10.6°, respectively. Mean carrying angle was 9° valgus at last follow-up. Mean flexion and extension were 134.4° and -6.0°, respectively. Change in carrying angle was statistically significant (p = 0.002). There were 2 grade 1 pin tract infections and 1 diaphyseal fracture of humerus. Functional outcome was rated excellent in 7 patients and good in 1 patient. Ilizarov distraction osteogenesis is a valuable alternative in treatment of elbow deformities in children. The surgical technique is simple and correction is adjustable. Gradual correction prevents possible neurovascular complications and minimally invasive surgery produces less scarring. Compliance of patient and family is key factor in the success of the outcome. Level IV, therapeutic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  17. Shielding cognition from nociception with working memory.

    PubMed

    Legrain, Valéry; Crombez, Geert; Plaghki, Léon; Mouraux, André

    2013-01-01

    Because pain often signals the occurrence of potential tissue damage, nociceptive stimuli have the capacity to capture attention and interfere with ongoing cognitive activities. Working memory is known to guide the orientation of attention by maintaining goal priorities active during the achievement of a task. This study investigated whether the cortical processing of nociceptive stimuli and their ability to capture attention are under the control of working memory. Event-related brain potentials (ERPs) were recorded while participants performed primary tasks on visual targets that required or did not require rehearsal in working memory (1-back vs 0-back conditions). The visual targets were shortly preceded by task-irrelevant tactile stimuli. Occasionally, in order to distract the participants, the tactile stimuli were replaced by novel nociceptive stimuli. In the 0-back conditions, task performance was disrupted by the occurrence of the nociceptive distracters, as reflected by the increased reaction times in trials with novel nociceptive distracters as compared to trials with standard tactile distracters. In the 1-back conditions, such a difference disappeared suggesting that attentional capture and task disruption induced by nociceptive distracters were suppressed by working memory, regardless of task demands. Most importantly, in the conditions involving working memory, the magnitude of nociceptive ERPs, including ERP components at early latency, were significantly reduced. This indicates that working memory is able to modulate the cortical processing of nociceptive input already at its earliest stages, and could explain why working memory reduces consequently ability of nociceptive stimuli to capture attention and disrupt performance of the primary task. It is concluded that protecting cognitive processing against pain interference is best guaranteed by keeping out of working memory pain-related information. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Preventing distracted driving among college students: Addressing smartphone use.

    PubMed

    Hassani, Sahar; Kelly, Erin H; Smith, Jennifer; Thorpe, Sara; Sozzer, Fatima H; Atchley, Paul; Sullivan, Elroy; Larson, Dean; Vogel, Lawrence C

    2017-02-01

    Based on the National Highway Traffic Safety Association's (NHTSA) Report, fatalities due to distracted driving are on the rise and the highest proportion of fatalities by age group is the 20-29 year old category. To date little has been done to educate college students about the dangers of distracted driving and engage these students in promoting a safe driving culture. Intervening among college students has the potential for making real-time behavior change, can foster a lifetime of safe driving habits among these students, and can help contribute to a culture of safe driving that can be created and sustained through positive messages from peers. The goals of this study were to develop, implement and evaluate a distracted driving presentation for college students to change knowledge, attitude and behavior on distracted driving. A 30-min, multi-media presentation on distracted driving was presented to 19 colleges and universities, totaling 444 college students (mean age 23.7±7.0 years of age, 61% females, 39% males). Students completed three surveys: prior to the workshop (interview 1), immediately after the workshop (interview 2), and 3 months following the workshop (interview 3). We assessed changes between interview 1 and interview 2 and found 15 of the 15 attitude-knowledge based questions significantly improved after the course. In addition, we assessed changes from interviews 1 and 3, and found 11 of the 15 attitude-knowledge based questions maintained their significance. Responses to behavior related questions at three months were also compared to baseline, and significant improvements were found for 12 of the 14 questions. While this study was successful in improving the short-term attitude-knowledge and behaviors on distracted driving, work is needed to sustain (and evaluate) long-term effects. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Maxillary segmental distraction in children with unilateral clefts of lip, palate, and alveolus.

    PubMed

    Zemann, Wolfgang; Pichelmayer, Margit

    2011-06-01

    Alveolar clefts are commonly closed by a bone grafting procedure. In cases of wide clefts the deficiency of soft tissue in the cleft area may lead to wound dehiscence and loss of the bony graft. Segmental maxillary bony transfer has been mentioned to be useful in such cases. Standard distraction devices allow unidirectional movement of the transported segment. Ideally the distraction should strictly follow the dental arch. The aim of this study was to analyze distraction devices that were adapted to the individual clinical situation of the patients. The goal was to achieve a distraction strictly parallel to the dental arch. Six children with unilateral clefts of lip, palate, and alveolus between 12 and 13 years of age were included in the study. The width of the cleft was between 7 and 19 mm. Dental cast models were used to manufacture individual distraction devices that should allow a segmental bony transport strictly parallel to the dental arch. Segmental osteotomy was performed under general anesthesia. Distraction was started 5 days after surgery. All distracters were tooth fixed but supported by palatal inserted orthodontic miniscrews. In all patients, a closure of the alveolar cleft was achieved. Two patients required additional bone grafting after the distraction procedure. The distraction was strictly parallel to the dental arch in all cases. In 1 case a slight cranial displacement of the transported maxillary segment could be noticed, leading to minor modifications of the following distractors. Distraction osteogenesis is a proper method to close wide alveolar clefts. Linear segmental transport is required in the posterior part of the dental arch, whereas in the frontal part the bony transport should run strictly parallel to the dental arch. An exact guided segmental transport may reduce the postoperative orthodontic complexity. Copyright © 2011 Mosby, Inc. All rights reserved.

  20. Tactile suppression of displacement.

    PubMed

    Ziat, Mounia; Hayward, Vincent; Chapman, C Elaine; Ernst, Marc O; Lenay, Charles

    2010-10-01

    In vision, the discovery of the phenomenon of saccadic suppression of displacement has made important contributions to the understanding of the stable world problem. Here, we report a similar phenomenon in the tactile modality. When scanning a single Braille dot with two fingers of the same hand, participants were asked to decide whether the dot was stationary or whether it was displaced from one location to another. The stimulus was produced by refreshable Braille devices that have dots that can be swiftly raised and recessed. In some conditions, the dot was stationary. In others, a displacement was created by monitoring the participant's finger position and by switching the dot activation when it was not touched by either finger. The dot displacement was of either 2.5 mm or 5 mm. We found that in certain cases, displaced dots were felt to be stationary. If the displacement was orthogonal to the finger movements, tactile suppression occurred effectively when it was of 2.5 mm, but when the displacement was of 5 mm, the participants easily detected it. If the displacement was medial-lateral, the suppression effect occurred as well, but less often when the apparent movement of the dot opposed the movement of the finger. In such cases, the stimulus appeared sooner than when the brain could predict it from finger movement, supporting a predictive rather than a postdictive differential processing hypothesis.

  1. Technical feasibility of personalized articulating knee joint distraction for treatment of tibiofemoral osteoarthritis.

    PubMed

    Struik, T; Jaspers, J E N; Besselink, N J; van Roermund, P M; Plomp, S; Rudert, M J; Lafeber, F P J G; Mastbergen, S C

    2017-11-01

    Knee osteoarthritis is a highly prevalent degenerative joint disorder characterized by joint tissue damage and pain. Knee joint distraction has been introduced as a joint preserving surgical procedure to postpone knee arthroplasty. An often used standard externally fixation device for distraction poses a burden to patients due to the absence of joint flexion during the 6weeks treatment. Therefore, a personalized articulating distraction device was developed. The aim of this study was to test technical feasibility of this device. Based on an often applied rigid device, using equal bone pin positions and connectors, a hinge mechanism was developed consisting of a cam-following system for reproducing the complex joint-specific knee kinematics. In support, a device was developed for capturing the joint-specific sagittal plane articulation. The obtained kinematic data were translated into joint-specific cam shapes that were installed bilaterally in the hinge mechanism of the distraction device, as such providing personalized knee motion. Distraction of 5mm was performed within a range of motion of 30deg. joint flexion. Pre-clinical evaluation of the working principle was performed on human cadaveric legs and system stiffness characteristics were biomechanically evaluated. The desired range of motion was obtained and distraction was maintained under physiologically representative loading. Moreover, the joint-specific approach demonstrated tolerance of deviations from anatomical and alignment origin during initial placement of the developed distraction device. Articulation during knee distraction is considered technically feasible and has potential to decrease burden and improve acceptance of distraction therapy. Testing of clinical feasibility is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. [Advances in the research of function of Merkel cells in tactile formation of skin].

    PubMed

    You, X; Wei, Z R

    2018-01-20

    Skin is the largest sense organ of human, with many mechanoreceptor cells under epidermis or dermis of skin and Merkel cell is one of them. It has been confirmed that Merkel cells play an important role in the process of mechanical transmission of mammalian soft tactile stimulation. Researches showed that Merkel cells had close relation to tactile formation and functioned by Merkel cell-neurite complexes and ion channels Piezo2. This article reviews Merkel cells and the function, problem and prospect of Merkel cells in tactile formation.

  3. Grunting's competitive advantage: Considerations of force and distraction.

    PubMed

    Sinnett, Scott; Maglinti, Cj; Kingstone, Alan

    2018-01-01

    Grunting is pervasive in many athletic contests, and empirical evidence suggests that it may result in one exerting more physical force. It may also distract one's opponent. That grunts can distract was supported by a study showing that it led to an opponent being slower and more error prone when viewing tennis shots. An alternative explanation was that grunting masks the sound of a ball being hit. The present study provides evidence against this alternative explanation by testing the effect of grunting in a sport-mixed martial arts-where distraction, rather than masking, is the most likely mechanism. We first confirmed that kicking force is increased when a grunt is performed (Experiment 1), and then adapted methodology used in the tennis study to mixed martial arts (Experiment 2). Lifting the foot to kick is a silent act, and therefore there is nothing for a grunt to mask, i.e., its effect on an opponent's response time and/or accuracy can likely be attributed to attentional distraction. Participants viewed videos of a trained mixed martial artist kicking that included, or did not include, a simulated grunt. The task was to determine as quickly as possible whether the kick was traveling upward or downward. Overall, and replicating the tennis finding, the present results indicate that a participant's response to a kick was delayed and more error prone when a simulated grunt was present. The present findings indicate that simulated grunting may distract an opponent, leading to slower and more error prone responses. The implications for martial arts in particular, and the broader question of whether grunting should be perceived as 'cheating' in sports, are examined.

  4. Psychometrics of Multiple Choice Questions with Non-Functioning Distracters: Implications to Medical Education.

    PubMed

    Deepak, Kishore K; Al-Umran, Khalid Umran; AI-Sheikh, Mona H; Dkoli, B V; Al-Rubaish, Abdullah

    2015-01-01

    The functionality of distracters in a multiple choice question plays a very important role. We examined the frequency and impact of functioning and non-functioning distracters on psychometric properties of 5-option items in clinical disciplines. We analyzed item statistics of 1115 multiple choice questions from 15 summative assessments of undergraduate medical students and classified the items into five groups by their number of non-functioning distracters. We analyzed the effect of varying degree of non-functionality ranging from 0 to 4, on test reliability, difficulty index, discrimination index and point biserial correlation. The non-functionality of distracters inversely affected the test reliability and quality of items in a predictable manner. The non-functioning distracters made the items easier and lowered the discrimination index significantly. Three non-functional distracters in a 5-option MCQ significantly affected all psychometric properties (p < 0.5). The corrected point biserial correlation revealed that the items with 3 functional options were psychometrically as effective as 5-option items. Our study reveals that a multiple choice question with 3 functional options provides lower most limit of item format that has adequate psychometric property. The test containing items with less number of functioning options have significantly lower reliability. The distracter function analysis and revision of nonfunctioning distracters can serve as important methods to improve the psychometrics and reliability of assessment.

  5. Google glass: a driver distraction cause or cure?

    PubMed

    Sawyer, Ben D; Finomore, Victor S; Calvo, Andres A; Hancock, P A

    2014-11-01

    We assess the driving distraction potential of texting with Google Glass (Glass), a mobile wearable platform capable of receiving and sending short-message-service and other messaging formats. A known roadway danger, texting while driving has been targeted by legislation and widely banned. Supporters of Glass claim the head-mounted wearable computer is designed to deliver information without concurrent distraction. Existing literature supports the supposition that design decisions incorporated in Glass might facilitate messaging for drivers. We asked drivers in a simulator to drive and use either Glass or a smartphone-based messaging interface, then interrupted them with an emergency brake event. Both the response event and subsequent recovery were analyzed. Glass-delivered messages served to moderate but did not eliminate distracting cognitive demands. A potential passive cost to drivers merely wearing Glass was also observed. Messaging using either device impaired driving as compared to driving without multitasking. Glass in not a panacea as some supporters claim, but it does point the way to design interventions that effect reduced load in multitasking. Discussions of these identified benefits are framed within the potential of new in-vehicle systems that bring both novel forms of distraction and tools for mitigation into the driver's seat.

  6. Incomplete mobilization of the maxilla resulting in failed maxillary distraction: a case report.

    PubMed

    Alkan, Alper; Inal, Samet; Baş, Burcu; Ozer, Mete

    2007-12-01

    Maxillary distraction osteogenesis has become an accepted alternative method in the treatment of patients with severe maxillary hypoplasia in craniofacial syndromes and cleft-related deformities. Insufficient distraction, undesirable soft tissue changes, and occurrence of defective distraction vectors are among the potential complications of intraoral maxillary distraction osteogenesis. A 2-stage procedure combining maxillary advancement by distraction technique with genioplasty and mandibular setback surgery was planned to correct jaw deformities in a 22-year-old patient with severe maxillary retrusion, mandibular prognathism, and excessive lower facial height. In the first stage, osteotomies were performed and maxilla was lightly mobilized after down-fracture. Distractors were placed to the maxilla intraorally. During activation period, the maxilla rotated in a clockwise direction, producing a discrepancy between the planned and the actual vectors. Complete distraction was unsatisfactory and the complication was due to surgical technique. This case report presents the failure of maxillary distraction due to incomplete mobilization of the maxilla. Treatment of the case was achieved by the conventional osteotomy techniques at final operation. The maxilla was successfully advanced to the desired position producing good occlusion and an improved facial profile.

  7. Injury prevention programs against distracted driving: Are they effective?

    PubMed

    Joseph, Bellal; Zangbar, Bardiya; Bains, Sandeep; Kulvatunyou, Narong; Khalil, Mazhar; Mahmoud, Dalal; Friese, Randall S; O'Keeffe, Terence; Pandit, Viraj; Rhee, Peter

    2016-07-03

    Distracted driving (talking and/or texting) is a growing public safety problem, with increasing incidence among adult drivers. The aim of this study was to identify the incidence of distracted driving (DD) among health care providers and to create awareness against DD. We hypothesized that distracted driving is prevalent among health care providers and a preventive campaign against distracted driving would effectively decrease distracted driving among health care providers. We performed a 4-phase prospective interventional study of all health care providers at our level 1 trauma center. Phase 1: one week of pre-intervention observation; phase 2: one week of intervention; phase 3: one week of postintervention observation; and phase 4: one week of 6 months of postintervention observation. Observations were performed outside employee parking garage at the following time intervals: 6:30-8:30 a.m., 4:40-5:30 p.m., and 6:30-7:30 p.m. Intervention included an e-mail survey, pamphlets and banners in the hospital cafeteria, and a postintervention survey. Hospital employees were identified with badges and scrubs, employees exiting through employee gate, and parking pass on the car. Outcome measure was incidence of DD pre, post, and 6 months postintervention. A total of 15,416 observations (pre: 6,639, post: 4,220, 6 months post: 4,557) and 520 survey responses were collected. The incident of DD was 11.8% among health care providers. There was a significant reduction in DD in each time interval of observation between pre- and postintervention. On subanalysis, there was a significant decrease in talking (P = .0001) and texting (P = .01) while driving postintervention compared to pre-intervention. In the survey, 35.5% of respondents admitted to DD and 4.5% respondents were involved in an accident due to DD. We found that 77% respondents felt more informed after the survey and 91% respondents supported a state legislation against DD. The reduction in the incidence of DD

  8. Sex differences in the response to emotional distraction: an event-related fMRI investigation.

    PubMed

    Iordan, Alexandru D; Dolcos, Sanda; Denkova, Ekaterina; Dolcos, Florin

    2013-03-01

    Evidence has suggested that women have greater emotional reactivity than men. However, it is unclear whether these differences in basic emotional responses are also associated with differences in emotional distractibility, and what the neural mechanisms that implement differences in emotional distractibility between women and men are. Functional MRI recording was used in conjunction with a working memory (WM) task, with emotional distraction (angry faces) presented during the interval between the memoranda and the probes. First, we found an increased impact of emotional distraction among women in trials associated with high-confidence responses, in the context of overall similar WM performance in women and men. Second, women showed increased sensitivity to emotional distraction in brain areas associated with "hot" emotional processing, whereas men showed increased sensitivity in areas associated with "cold" executive processing, in the context of overall similar patterns of response to emotional distraction in women and men. Third, a sex-related dorsal-ventral hemispheric dissociation emerged in the lateral PFC related to coping with emotional distraction, with women showing a positive correlation with WM performance in left ventral PFC, and men showing similar effects in the right dorsal PFC. In addition to extending to men results that have previously been reported in women, by showing that both sexes engage mechanisms that are similar overall in response to emotional distraction, the present study identifies sex differences in both the response to and coping with emotional distraction. These results have implications for understanding sex differences in the susceptibility to affective disorders, in which basic emotional responses, emotional distractibility, and coping abilities are altered.

  9. Virtual Reality: A Distraction Intervention for Chemotherapy

    PubMed Central

    Schneider, Susan M.; Hood, Linda E.

    2007-01-01

    Purpose/Objectives To explore virtual reality (VR) as a distraction intervention to relieve symptom distress in adults receiving chemotherapy treatments for breast, colon, and lung cancer. Design Crossover design in which participants served as their own control. Setting Outpatient clinic at a comprehensive cancer center in the southeastern United States. Sample 123 adults receiving initial chemotherapy treatments. Methods Participants were randomly assigned to receive the VR distraction intervention during one chemotherapy treatment and then received no intervention (control) during an alternate matched chemotherapy treatment. The Adapted Symptom Distress Scale–2, Revised Piper Fatigue Scale, and State Anxiety Inventory were used to measure symptom distress. The Presence Questionnaire and an open-ended questionnaire were used to evaluate the subjects’ VR experience. The influence of type of cancer, age, and gender on symptom outcomes was explored. Mixed models were used to test for differences in levels of symptom distress. Main Research Variables Virtual reality and symptom distress. Findings Patients had an altered perception of time (p < 0.001) when using VR, which validates the distracting capacity of the intervention. Evaluation of the intervention indicated that patients believed the head-mounted device was easy to use, they experienced no cybersickness, and 82% would use VR again. However, analysis demonstrated no significant differences in symptom distress immediately or two days following chemotherapy treatments. Conclusions Patients stated that using VR made the treatment seem shorter and that chemotherapy treatments with VR were better than treatments without the distraction intervention. However, positive experiences did not result in a decrease in symptom distress. The findings support the idea that using VR can help to make chemotherapy treatments more tolerable, but clinicians should not assume that use of VR will improve chemotherapy

  10. Integration of Hand and Finger Location in External Spatial Coordinates for Tactile Localization

    ERIC Educational Resources Information Center

    Heed, Tobias; Backhaus, Jenny; Roder, Brigitte

    2012-01-01

    Tactile stimulus location is automatically transformed from somatotopic into external spatial coordinates, rendering information about the location of touch in three-dimensional space. This process is referred to as tactile remapping. Whereas remapping seems to occur automatically for the hands and feet, the fingers may constitute an exception in…

  11. Tactile feedback for relief of deafferentation pain using virtual reality system: a pilot study.

    PubMed

    Sano, Yuko; Wake, Naoki; Ichinose, Akimichi; Osumi, Michihiro; Oya, Reishi; Sumitani, Masahiko; Kumagaya, Shin-Ichiro; Kuniyoshi, Yasuo

    2016-06-28

    Previous studies have tried to relieve deafferentation pain (DP) by using virtual reality rehabilitation systems. However, the effectiveness of multimodal sensory feedback was not validated. The objective of this study is to relieve DP by neurorehabilitation using a virtual reality system with multimodal sensory feedback and to validate the efficacy of tactile feedback on immediate pain reduction. We have developed a virtual reality rehabilitation system with multimodal sensory feedback and applied it to seven patients with DP caused by brachial plexus avulsion or arm amputation. The patients executed a reaching task using the virtual phantom limb manipulated by their real intact limb. The reaching task was conducted under two conditions: one with tactile feedback on the intact hand and one without. The pain intensity was evaluated through a questionnaire. We found that the task with the tactile feedback reduced DP more (41.8 ± 19.8 %) than the task without the tactile feedback (28.2 ± 29.5 %), which was supported by a Wilcoxon signed-rank test result (p < 0.05). Overall, our findings indicate that the tactile feedback improves the immediate pain intensity through rehabilitation using our virtual reality system.

  12. Vibration-enhanced posture stabilization achieved by tactile supplementation: may blind individuals get extra benefits?

    PubMed

    Magalhães, Fernando Henrique; Kohn, André Fabio

    2011-08-01

    Diminished balance ability poses a serious health risk due to the increased likelihood of falling, and impaired postural stability is significantly associated with blindness and poor vision. Noise stimulation (by improving the detection of sub-threshold somatosensory information) and tactile supplementation (i.e., additional haptic information provided by an external contact surface) have been shown to improve the performance of the postural control system. Moreover, vibratory noise added to the source of tactile supplementation (e.g., applied to a surface that the fingertip touches) has been shown to enhance balance stability more effectively than tactile supplementation alone. In view of the above findings, in addition to the well established consensus that blind subjects show superior abilities in the use of tactile information, we hypothesized that blind subjects may take extra benefits from the vibratory noise added to the tactile supplementation and hence show greater improvements in postural stability than those observed for sighted subjects. If confirmed, this hypothesis may lay the foundation for the development of noise-based assistive devices (e.g., canes, walking sticks) for improving somatosensation and hence prevent falls in blind individuals. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Potential distractions and unsafe driving behaviors among drivers of 1- to 12-year-old children.

    PubMed

    Macy, Michelle L; Carter, Patrick M; Bingham, C Raymond; Cunningham, Rebecca M; Freed, Gary L

    2014-01-01

    Driver distraction has been identified as a threat to individual drivers and public health. Motor vehicle collisions remain a leading cause of death for children, yet little is known about distractions among drivers of children. This study sought to characterize potential distractions among drivers of children. A 2-site, cross-sectional, computerized survey of child passenger safety practices was conducted among adult drivers of 1- to 12-year-old children who presented for emergency care between October 2011 to May 2012. Drivers indicated the frequency with which they engaged in 10 potential distractions in the past month while driving with their child. Distractions were grouped in 4 categories: (1) nondriving, (2) cellular phone, (3) child, and (4) directions. Information about other unsafe driving behaviors and sociodemographic characteristics was collected. Nearly 90% of eligible parents participated. Analysis included 570 drivers (92.2%). Non-driving-related and cellular phone-related distractions were disclosed by >75% of participants. Fewer participants disclosed child (71.2%) and directions-related distractions (51.9%). Child age was associated with each distraction category. Cellular phone-related distractions were associated with the child riding daily in the family car, non-Hispanic white, and higher education. Parents admitting to drowsy driving and being pulled over for speeding had over 2 times higher odds of disclosing distractions from each category. Distracted driving activities are common among drivers of child passengers and are associated with other unsafe driving behaviors. Child passenger safety may be improved by preventing crash events through the reduction or elimination of distractions among drivers of child passengers. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  14. Potential Distractions and Unsafe Driving Behaviors Among Drivers of 1- to 12-year-old Children

    PubMed Central

    Macy, Michelle L.; Carter, Patrick M.; Bingham, C. Raymond; Cunningham, Rebecca M.; Freed, Gary L.

    2014-01-01

    Objective Driver distraction has been identified as a threat to individual drivers and public health. Motor vehicle collisions remain a leading cause of death for children yet little is known about distractions among drivers of children. This study sought to characterize potential distractions among drivers of children. Methods A two-site, cross-sectional, computerized survey of child passenger safety practices was conducted among adult drivers of 1- to 12-year-old children who presented for emergency care between October 2011-May 2012. Drivers indicated the frequency with which they engaged in ten potential distractions in the past month while driving with their child. Distractions were grouped in four categories: 1) non-driving, 2) cellular phone, 3) child, 4) directions. Information about other unsafe driving behaviors and sociodemographic characteristics was collected. Results Nearly 90% of eligible parents participated. Analysis included 570 (92.2%) drivers. Non-driving and cellular phone-related distractions were disclosed by >75% of participants. Fewer participants disclosed child (71.2%) and directions-related distractions (51.9%). Child age was associated with each distraction category. Cellular phone-related distractions were associated with the child riding daily in the family car, non-Hispanic white and other race/ethnicity, and higher education. Parents admitting to drowsy driving and being pulled over for speeding had over two-times higher odds of disclosing distractions from each category. Conclusions Distracted driving activities are common among drivers of child passengers and associated with other unsafe driving behaviors. Child passenger safety may be improved by preventing crash events through the reduction or elimination of distractions among drivers of child passengers. PMID:24767781

  15. An Examination of the Potential for Blissymbolics to Serve as the Foundation for a Tactile Symbol System

    ERIC Educational Resources Information Center

    Isaacson, Mickey

    2012-01-01

    The primary purpose of this study was to determine whether Blissymbolics have the potential for being developed into a tactile symbol communication system. Tactile techniques are used by many individuals with augmentative and alternative communication (AAC) needs. Tactile processing is optimized by the use of minimalistic stimuli, i.e., stimuli…

  16. Influences shaping nurses' use of distraction for children's procedural pain.

    PubMed

    Olmstead, Deborah L; Scott, Shannon D; Mayan, Maria; Koop, Priscilla M; Reid, Kathy

    2014-04-01

    This study explored pediatric nurses' choices to use distraction for managing painful procedures. Using interpretive description approaches, interviews with pediatric nurses provided descriptions of choices to manage procedural pain. Nurses' distress influenced distraction use to mitigate the suffering of children and themselves. Newer nurses described task mastery as influencing distraction choices. Nurses' accounts of performing painful procedures on children mirrored children's descriptions of pain from the literature. Nurses' distress and competency performing painful procedures on children influenced practice. Future qualitative studies could extend understanding of pain management choices by pediatric nurses and the impact on undermanaged pain. © 2014, Wiley Periodicals, Inc.

  17. Parathyroid hormone therapy mollifies radiation-induced biomechanical degradation in murine distraction osteogenesis.

    PubMed

    Deshpande, Sagar S; Gallagher, Katherine K; Donneys, Alexis; Tchanque-Fossuo, Catherine N; Sarhaddi, Deniz; Nelson, Noah S; Chepeha, Douglas B; Buchman, Steven R

    2013-07-01

    Descriptions of mandibular distraction osteogenesis for tissue replacement after oncologic resection or for defects caused by osteoradionecrosis have been limited. Previous work demonstrated radiation decreases union formation, cellularity and mineral density in mandibular distraction osteogenesis. The authors posit that intermittent systemic administration of parathyroid hormone will serve as a stimulant to cellular function, reversing radiation-induced damage and enhancing bone regeneration. Twenty male Lewis rats were randomly assigned to three groups: group 1 (radiation and distraction osteogenesis, n = 7) and group 2 (radiation, distraction osteogenesis, and parathyroid hormone, n = 5) received a human-equivalent dose of 35 Gy of radiation (human bioequivalent, 70 Gy) fractionated over 5 days. All groups, including group 3 (distraction osteogenesis, n = 8), underwent a left unilateral mandibular osteotomy with bilateral external fixator placement. Distraction osteogenesis was performed at a rate of 0.3 mm every 12 hours to reach a gap of 5.1 mm. Group 2 was injected with parathyroid hormone (60 µg/kg) subcutaneously daily for 3 weeks after the start of distraction osteogenesis. On postoperative day 40, all left hemimandibles were harvested. Biomechanical response parameters were generated. Statistical significance was considered at p ≤ 0.05. Parathyroid hormone-treated mandibles had significantly higher failure load and higher yield than did untreated mandibles. However, these values were still significantly lower than those of nonirradiated mandibles. The authors have successfully demonstrated the therapeutic efficacy of parathyroid hormone to stimulate and enhance bone regeneration in their irradiated murine mandibular model of distraction osteogenesis. Anabolic regimens of parathyroid hormone, a U.S. Food and Drug Administration-approved drug on formulary, significantly improve outcomes in a model of postoncologic craniofacial reconstruction.

  18. Time course of emotion-related responding during distraction and reappraisal

    PubMed Central

    Schönfelder, Sandra; Kanske, Philipp; Heissler, Janine

    2014-01-01

    Theoretical accounts of emotion regulation (ER) discriminate various cognitive strategies to voluntarily modify emotional states. Amongst these, attentional deployment (i.e. distraction) and cognitive change (i.e. reappraisal), have been shown to successfully down-regulate emotions. Neuroimaging studies found that both strategies differentially engage neural structures associated with selective attention, working memory and cognitive control. The aim of this study was to further delineate similarities and differences between the ER strategies reappraisal and distraction by investigating their temporal brain dynamics using event-related potentials (ERPs) and their patterns of facial expressive behavior. Twenty-one participants completed an ER experiment in which they had to either passively view positive, neutral and negative pictures, reinterpret them to down-regulate affective responses (reappraisal), or solve a concurrently presented mathematical equation (distraction). Results demonstrate the efficacy of both strategies in the subjective control of emotion, accompanied by reductions of facial expressive activity (Corrugator supercilii and Zygomaticus major). ERP results indicated that distraction, compared with reappraisal, yielded a stronger and earlier attenuation of the late positive potential (LPP) magnitude for negative pictures. For positive pictures, only distraction but not reappraisal had significant effect on LPP attenuation. The results support the process model of ER, separating subtypes of cognitive strategies based on their specific time course. PMID:23988760

  19. Do absorption and realistic distraction influence performance of component task surgical procedure?

    PubMed

    Pluyter, Jon R; Buzink, Sonja N; Rutkowski, Anne-F; Jakimowicz, Jack J

    2010-04-01

    Surgeons perform complex tasks while exposed to multiple distracting sources that may increase stress in the operating room (e.g., music, conversation, and unadapted use of sophisticated technologies). This study aimed to examine whether such realistic social and technological distracting conditions may influence surgical performance. Twelve medical interns performed a laparoscopic cholecystectomy task with the Xitact LC 3.0 virtual reality simulator under distracting conditions (exposure to music, conversation, and nonoptimal handling of the laparoscope) versus nondistracting conditions (control condition) as part of a 2 x 2 within-subject experimental design. Under distracting conditions, the medical interns showed a significant decline in task performance (overall task score, task errors, and operating time) and significantly increased levels of irritation toward both the assistant handling the laparoscope in a nonoptimal way and the sources of social distraction. Furthermore, individual differences in cognitive style (i.e., cognitive absorption and need for cognition) significantly influenced the levels of irritation experienced by the medical interns. The results suggest careful evaluation of the social and technological sources of distraction in the operation room to reduce irritation for the surgeon and provision of proper preclinical laparoscope navigation training to increase security for the patient.

  20. Distracting people from sources of discomfort in a simulated aircraft environment.

    PubMed

    Lewis, Laura; Patel, Harshada; Cobb, Sue; D'Cruz, Mirabelle; Bues, Matthias; Stefani, Oliver; Grobler, Tredeaux

    2016-07-19

    Comfort is an important factor in the acceptance of transport systems. In 2010 and 2011, the European Commission (EC) put forward its vision for air travel in the year 2050 which envisaged the use of in-flight virtual reality. This paper addressed the EC vision by investigating the effect of virtual environments on comfort. Research has shown that virtual environments can provide entertaining experiences and can be effective distracters from painful experiences. To determine the extent to which a virtual environment could distract people from sources of discomfort. Experiments which involved inducing discomfort commonly experienced in-flight (e.g. limited space, noise) in order to determine the extent to which viewing a virtual environment could distract people from discomfort. Virtual environments can fully or partially distract people from sources of discomfort, becoming more effective when they are interesting. They are also more effective at distracting people from discomfort caused by restricted space than noise disturbances. Virtual environments have the potential to enhance passenger comfort by providing positive distractions from sources of discomfort. Further research is required to understand more fully the reasons why the effect was stronger for one source of discomfort than the other.

  1. Genetically identified spinal interneurons integrating tactile afferents for motor control

    PubMed Central

    Panek, Izabela; Farah, Carl

    2015-01-01

    Our movements are shaped by our perception of the world as communicated by our senses. Perception of sensory information has been largely attributed to cortical activity. However, a prior level of sensory processing occurs in the spinal cord. Indeed, sensory inputs directly project to many spinal circuits, some of which communicate with motor circuits within the spinal cord. Therefore, the processing of sensory information for the purpose of ensuring proper movements is distributed between spinal and supraspinal circuits. The mechanisms underlying the integration of sensory information for motor control at the level of the spinal cord have yet to be fully described. Recent research has led to the characterization of spinal neuron populations that share common molecular identities. Identification of molecular markers that define specific populations of spinal neurons is a prerequisite to the application of genetic techniques devised to both delineate the function of these spinal neurons and their connectivity. This strategy has been used in the study of spinal neurons that receive tactile inputs from sensory neurons innervating the skin. As a result, the circuits that include these spinal neurons have been revealed to play important roles in specific aspects of motor function. We describe these genetically identified spinal neurons that integrate tactile information and the contribution of these studies to our understanding of how tactile information shapes motor output. Furthermore, we describe future opportunities that these circuits present for shedding light on the neural mechanisms of tactile processing. PMID:26445867

  2. Visual and tactile interfaces for bi-directional human robot communication

    NASA Astrophysics Data System (ADS)

    Barber, Daniel; Lackey, Stephanie; Reinerman-Jones, Lauren; Hudson, Irwin

    2013-05-01

    Seamless integration of unmanned and systems and Soldiers in the operational environment requires robust communication capabilities. Multi-Modal Communication (MMC) facilitates achieving this goal due to redundancy and levels of communication superior to single mode interaction using auditory, visual, and tactile modalities. Visual signaling using arm and hand gestures is a natural method of communication between people. Visual signals standardized within the U.S. Army Field Manual and in use by Soldiers provide a foundation for developing gestures for human to robot communication. Emerging technologies using Inertial Measurement Units (IMU) enable classification of arm and hand gestures for communication with a robot without the requirement of line-of-sight needed by computer vision techniques. These devices improve the robustness of interpreting gestures in noisy environments and are capable of classifying signals relevant to operational tasks. Closing the communication loop between Soldiers and robots necessitates them having the ability to return equivalent messages. Existing visual signals from robots to humans typically require highly anthropomorphic features not present on military vehicles. Tactile displays tap into an unused modality for robot to human communication. Typically used for hands-free navigation and cueing, existing tactile display technologies are used to deliver equivalent visual signals from the U.S. Army Field Manual. This paper describes ongoing research to collaboratively develop tactile communication methods with Soldiers, measure classification accuracy of visual signal interfaces, and provides an integration example including two robotic platforms.

  3. Weber's Illusion and Body Shape: Anisotropy of Tactile Size Perception on the Hand

    ERIC Educational Resources Information Center

    Longo, Matthew R.; Haggard, Patrick

    2011-01-01

    The perceived distance between touches on a single skin surface is larger on regions of high tactile sensitivity than those with lower acuity, an effect known as "Weber's illusion". This illusion suggests that tactile size perception involves a representation of the perceived size of body parts preserving characteristics of the somatosensory…

  4. Designing feedback to mitigate teen distracted driving: A social norms approach.

    PubMed

    Merrikhpour, Maryam; Donmez, Birsen

    2017-07-01

    The purpose of this research is to investigate teens' perceived social norms and whether providing normative information can reduce distracted driving behaviors among them. Parents are among the most important social referents for teens; they have significant influences on teens' driving behaviors, including distracted driving which significantly contributes to teens' crash risks. Social norms interventions have been successfully applied in various domains including driving; however, this approach is yet to be explored for mitigating driver distraction among teens. Forty teens completed a driving simulator experiment while performing a self-paced visual-manual secondary task in four between-subject conditions: a) social norms feedback that provided a report at the end of each drive on teens' distracted driving behavior, comparing their distraction engagement to their parent's, b) post-drive feedback that provided just the report on teens' distracted driving behavior without information on their parents, c) real-time feedback in the form of auditory warnings based on eyes of road-time, and d) no feedback as control. Questionnaires were administered to collect data on these teens' and their parents' self-reported engagement in driver distractions and the associated social norms. Social norms and real-time feedback conditions resulted in significantly smaller average off-road glance duration, rate of long (>2s) off-road glances, and standard deviation of lane position compared to no feedback. Further, social norms feedback decreased brake response time and percentage of time not looking at the road compared to no feedback. No major effect was observed for post-drive feedback. Questionnaire results suggest that teens appeared to overestimate parental norms, but no effect of feedback was found on their perceptions. Feedback systems that leverage social norms can help mitigate driver distraction among teens. Overall, both social norms and real-time feedback induced

  5. Management of post midface distraction occlusal discrepancy using temporary anchorage devices in a cleft patient

    PubMed Central

    Koteswara Prasad, N. K.; Hussain, Syed Altaf; Chitharanjan, Arun B.; Murthy, Jyotsna

    2015-01-01

    Open bite deformity following a successful midface advancement by distraction osteogenesis is a common complication. Temporary anchorage devices can be deployed during the distraction and post-distraction settling phases for restoring the occlusion even in severe cases. The following report describes the management of severe anterior open bite following maxillary distraction. PMID:25991895

  6. Long-term follow-up after maxillary distraction osteogenesis in growing children with cleft lip and palate.

    PubMed

    Huang, Chiung-Shing; Harikrishnan, Pandurangan; Liao, Yu-Fang; Ko, Ellen W C; Liou, Eric J W; Chen, Philip K T

    2007-05-01

    To evaluate the changes in maxillary position after maxillary distraction osteogenesis in six growing children with cleft lip and palate. Retrospective, longitudinal study on maxillary changes at A point, anterior nasal spine, posterior nasal spine, central incisor, and first molar. The University Hospital Craniofacial Center. Cephalometric radiographs were used to measure the maxillary position immediately after distraction, at 6 months, and more than 1 year after distraction. After maxillary distraction with a rigid external distraction device, the maxilla (A point) on average moved forward 9.7 mm and downward 3.5 mm immediately after distraction, moved backward 0.9 mm and upward 2.0 mm after 6 months postoperatively, and then moved further backward 2.3 mm and downward 6.8 mm after more than 1 year from the predistraction position. In most cases, maxilla moved forward at distraction and started to move backward until 1 year after distraction, but remained forward, as compared with predistraction position. Maxilla also moved downward during distraction and upward in 6 months, but started descending in 1 year. There also was no further forward growth of the maxilla after distraction in growing children with clefts.

  7. Complications of the Intramedullary Skeletal Kinetic Distractor (ISKD) in distraction osteogenesis.

    PubMed

    Lee, Dong Hoon; Ryu, Keun Jung; Song, Hae Ryong; Han, Soo-Hong

    2014-12-01

    The Intramedullary Skeletal Kinetic Distractor (ISKD) (Orthofix Inc, Lewisville, TX, USA) is an intramedullary device designed for more comfortable limb lengthening than that with external fixators; lengthening is achieved with this nail using rotational oscillation between two telescoping sections. However, the degree to which this device achieves this goal and its complication rate have not been fully documented. We determined (1) the frequency with which distraction was not achieved at the desired rate, (2) whether pain differed between patients with normally and abnormally distracting nails, (3) risk factors for abnormal nails, and (4) other complications. We analyzed 35 lengthening segments (26 femurs, nine tibias) in 19 patients. Mean length achieved was 47 mm. Femoral nails were categorized into four groups according to distraction rate: normal, runaway (unintentionally faster rate [> 1.5 mm/day]), difficult-to-distract (slower rate [< 0.8 mm/day] requiring manual manipulation but not requiring general anesthesia), and nondistracting (slower rate [< 0.8 mm/day] requiring manual manipulation under general anesthesia or reosteotomy). Possible risk factors, including age, BMI, preoperative thigh circumferences, degree of intramedullary overreaming, and length of the thicker portion of the nail within the distal fragment, were compared among groups. VAS pain scores were compared among groups under three conditions: rest, physiotherapy, and distraction motion. Complications were also analyzed. Minimum followup was 15 months (mean, 26 months; range, 15-38 months) after first-stage surgery. Abnormal distraction rate was observed in 21 of 35 segments (60%; 17 femurs, four tibias). VAS pain scores showed no differences among groups during rest or physiotherapy but were higher (p = 0.02) in the problematic nails (7-8 points) versus normal nails (3 points) during distraction. Only mean length of the thicker portion of the nail within the distal fragment

  8. Ultrasound control of magnet growing rod distraction in early onset scoliosis.

    PubMed

    Pérez Cervera, T; Lirola Criado, J F; Farrington Rueda, D M

    2016-01-01

    The growing rod technique is currently one of the most common procedures used in the management of early onset scoliosis. However, in order to preserve spine growth and control the deformity it requires frequent surgeries to distract the rods. Magnetically driven growing rods have recently been introduced with same treatment goal, but without the inconvenience of repeated surgical distractions. One of the limitations of this technical advance is an increase in radiation exposure due to the increase in distraction frequency compared to conventional growing rods. An improvement of the original technique is presented, proposing a solution to the inconvenience of multiple radiation exposure using ultrasound technology to control the distraction process of magnetically driven growing rods. Copyright © 2014 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Driver distraction: a perennial but preventable public health threat to adolescents.

    PubMed

    Bingham, C Raymond

    2014-05-01

    Although public health efforts have made some progress in reducing risk of adolescent motor vehicle crashes over the last three decades, new technologies and evolving behavior patterns have focused attention on the risk of distracted driving. For many of the same reasons that alcohol-impaired driving represents a distinct risk for adolescents, distracted driving has an elevated impact on this age group. Similarly, many of the strategies used to reduce alcohol-impaired driving among adolescents might be applied to driver distraction, including adults serving as role models with high standards of behavior. The unique challenge posed by the proliferation of new technological distractions may accelerate this risk behavior and may lend itself to innovative prevention efforts. Copyright © 2014 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  10. Nonvascularized toe phalangeal transfer and distraction lengthening for symbrachydactyly.

    PubMed

    Patterson, Ryan W; Seitz, William H

    2010-04-01

    Symbrachydactyly describes a spectrum of congenital hand differences consisting of digital loss resulting in fused short fingers. As the principles for distraction lengthening have evolved, the technique of nonvascularized toe phalangeal transfer to the hand with shortened digits has provided patients with improved outcomes. Nonvascularized toe phalanx to hand transplant with distraction lengthening restores functional length to a skeletally deficient, poorly functioning hand while maintaining an overlying layer of vascular and sensate tissue. The primary goal is improvement of digital length to enhance mechanical advantage and prehension. We describe the technique of nonvascularized toe phalangeal transfer and distraction lengthening for symbrachydactyly, including the following steps: nonvascularized proximal toe phalanx harvest, toe phalanx transfer to hand, pin placement, osteotomy, and closure.

  11. The effect of ankle distraction on arthroscopic evaluation of syndesmotic instability: A cadaveric study.

    PubMed

    Lubberts, Bart; Guss, Daniel; Vopat, Bryan G; Wolf, Jonathon C; Moon, Daniel K; DiGiovanni, Christopher W

    2017-12-01

    To assist with visualization, orthopaedic surgeons often apply ankle distraction during arthroscopic procedures. The study aimed to investigate whether ankle distraction suppresses fibular motion in cadaveric specimens with an unstable syndesmotic injury. Fourteen fresh-frozen above knee specimens underwent arthroscopic assessment with 1) intact ligaments, 2) after sectioning of the anterior inferior tibiofibular ligament, the interosseous ligament, and the posterior inferior tibiofibular ligament, and 3) after sectioning of the deep and superficial deltoid ligament. In all scenarios, the lateral hook test, anterior-posterior hook test, and posterior-anterior hook test were applied. Each test was performed with and without ankle distraction. Coronal plane anterior and posterior tibiofibular diastasis as well as sagittal plane tibiofibular translation due to the applied load were arthroscopically measured. Tibiofibular diastasis in the coronal plane, as measured at both the anterior and posterior third of the incisura, was found to be significantly less when ankle distraction was applied, as compared to arthroscopic evaluation in the absence of distraction. In contrast, measurement of sagittal plane tibiofibular translation was not affected by ankle distraction. Since arthroscopic findings of syndesmotic instability are subtle the differential values of the syndesmotic measurements taken on and off distraction are clinically relevant. To optimally assess syndesmotic instability one should evaluate the syndesmosis without distraction or focus on fibular motion in the sagittal plane when distraction is required. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Direct hip joint distraction during acetabular fracture surgery using the AO universal manipulator.

    PubMed

    Calafi, L Afshin; Routt, M L Chip

    2010-02-01

    Certain acetabular fractures may necessitate distraction of the hip joint for removal of intra-articular debris and assessment of reduction. Distraction can be accomplished by manual traction, using a traction table or an AO universal manipulator (UM). The UM is a relatively simple and an inexpensive device that can provide focal distraction in a controlled manner without the risks associated with the use of a traction table. We describe a technique using the UM for hip joint distraction during acetabular fracture surgery through a Kocher-Langenbeck surgical exposure.

  13. Grunting's competitive advantage: Considerations of force and distraction

    PubMed Central

    Maglinti, Cj; Kingstone, Alan

    2018-01-01

    Background Grunting is pervasive in many athletic contests, and empirical evidence suggests that it may result in one exerting more physical force. It may also distract one's opponent. That grunts can distract was supported by a study showing that it led to an opponent being slower and more error prone when viewing tennis shots. An alternative explanation was that grunting masks the sound of a ball being hit. The present study provides evidence against this alternative explanation by testing the effect of grunting in a sport—mixed martial arts—where distraction, rather than masking, is the most likely mechanism. Methodology/Principal findings We first confirmed that kicking force is increased when a grunt is performed (Experiment 1), and then adapted methodology used in the tennis study to mixed martial arts (Experiment 2). Lifting the foot to kick is a silent act, and therefore there is nothing for a grunt to mask, i.e., its effect on an opponent’s response time and/or accuracy can likely be attributed to attentional distraction. Participants viewed videos of a trained mixed martial artist kicking that included, or did not include, a simulated grunt. The task was to determine as quickly as possible whether the kick was traveling upward or downward. Overall, and replicating the tennis finding, the present results indicate that a participant's response to a kick was delayed and more error prone when a simulated grunt was present. Conclusions/Significance The present findings indicate that simulated grunting may distract an opponent, leading to slower and more error prone responses. The implications for martial arts in particular, and the broader question of whether grunting should be perceived as 'cheating' in sports, are examined. PMID:29470505

  14. Ankle joint distraction arthroplasty for severe ankle arthritis.

    PubMed

    Xu, Yang; Zhu, Yuan; Xu, Xiang-Yang

    2017-02-28

    Ankle distraction arthroplasty is one option for the treatment of severe ankle arthritis in young patients. The outcomes and factors predicting success in distraction arthroplasty are poorly understood. From January 2011 to May 2015, 16 patients who had undergone ankle distraction arthroplasty for ankle arthritis were operated, including six males and ten females. All patients were available for analysis. The main outcome measurements included joint space on weight bearing radiographs, AOFAS-AH scores (American Orthopaedic Foot & Ankle Society ankle-hindfoot score), VAS scores and SF-36 scores. All 16 patients were followed for a mean follow-up of 40.9 ± 14.7 months (range, 17-67 months). Fourteen of the 16 patients still had their native ankle joints. One patient had undergone ankle arthrodesis 1 year after the operation and one patient had converted to spontaneous ankle fusion at the 3 years follow-up postoperative. The VAS score improved from 5.9 ± 0.8 to 3.7 ± 2.2 (p = 0.0028). The mean AOFAS-AH score improved from 41.9 ± 7.2 preoperatively to 68.1 ± 20.0 postoperatively (p = 0.001). The mean SF-36 score improved from 43.1 ± 7.6 preoperatively to 62.7 ± 18.8 postoperatively (p = 0.002). A weight-bearing ankle space larger than 3 mm at 1 year following distraction is a positive predictive factor. In this study, the treatment of ankle motion distraction for end stage ankle arthritis showed benefit in 9/16 (56.25%) patients at 41 months. It is a promising method for young patients with severe ankle arthritis.

  15. Non-erotic cognitive distractions during sexual activity in sexual minority and heterosexual young adults.

    PubMed

    Lacefield, Katharine; Negy, Charles

    2012-04-01

    The present study examined 100 lesbian and gay college students and 100 heterosexual students to determine whether group differences exist in frequency of a range of non-erotic cognitive distractions during sexual activity. Non-erotic cognitive distraction is a descriptive term for both self-evaluative cognitions related to physical performance and body image concerns, as well as additional cognitive distractions (e.g., contracting an STI or emotional concerns) during sexual activity. Participants were matched on gender (96 males and 104 females), age, and ethnicity, and completed questionnaires assessing frequency of non-erotic cognitive distractions during sexual activity, as well as measures of additional variables (trait and body image anxiety, attitudes toward sexual minorities, self-esteem, and religiosity). Results indicated that sexual minorities experienced significantly more cognitive distractions related to body image, physical performance, and STIs during sexual activity than heterosexuals. Regarding gender, men reported more distractions related to STIs than women. Interaction effects were observed between sexual orientation and gender for body image-, disease-, and external/emotional-based distractions. Implications of these findings are discussed.

  16. Development of CMOS MEMS inductive type tactile sensor with the integration of chrome steel ball force interface

    NASA Astrophysics Data System (ADS)

    Yeh, Sheng-Kai; Chang, Heng-Chung; Fang, Weileun

    2018-04-01

    This study presents an inductive tactile sensor with a chrome steel ball sensing interface based on the commercially available standard complementary metal-oxide-semiconductor (CMOS) process (the TSMC 0.18 µm 1P6M CMOS process). The tactile senor has a deformable polymer layer as the spring of the device and no fragile suspended thin film structures are required. As a tactile force is applied on the chrome steel ball, the polymer would deform. The distance between the chrome steel ball and the sensing coil would changed. Thus, the tactile force can be detected by the inductance change of the sensing coil. In short, the chrome steel ball acts as a tactile bump as well as the sensing interface. Experimental results show that the proposed inductive tactile sensor has a sensing range of 0-1.4 N with a sensitivity of 9.22(%/N) and nonlinearity of 2%. Preliminary wireless sensing test is also demonstrated. Moreover, the influence of the process and material issues on the sensor performances have also been investigated.

  17. Distraction-free ankle arthroscopy for anterolateral impingement.

    PubMed

    Rouvillain, Jean Louis; Daoud, Wael; Donica, Adrian; Garron, Emmanuel; Uzel, André Pierre

    2014-08-01

    The origin of chronic pain after external ankle sprain is better known with arthroscopy's contribution. Chronic hypertrophic synovitis of the anterolateral ankle region is seemingly the cause, resulting in "anterolateral ankle impingement." But is partial synovectomy with fibrosis resection under arthroscopy always possible without any distraction? Are results affected? This retrospective study concerned only patients with soft tissue ankle impingement. All cases with bone and joint diseases were excluded. The final sample of 24 patients had a mean age of 35 years (21-54 years) and presented anterolateral mechanical pain associated with oedema following external ankle sprain. Medical and rehabilitative treatment was undertaken for more than 6 months before arthroscopy. Average time between trauma and arthroscopy was 21 months (5-60 months). Clinical examination revealed no ankle instability or laxity. Debridement with joint lavage was systematically performed under arthroscopy without any distraction. Average patient follow-up was 22 months (12-92 months). All patients had a good Kitaoka score, with 22 patients registering excellent results. There were no septic complications or algodystrophy. Two transient hypoesthesias were observed in the dorsal surface and lateral border of the foot with full postoperative recovery at 6 months. Distraction was never used and simple dorsiflexion was sufficient to perform arthroscopic debridement. In this study, anterolateral ankle impingement diagnosis was primarily clinical. Arthroscopic treatment yielded significant benefits on pain, oedema and resumption of sport activities. Arthroscopic treatment of anterolateral ankle impingements is thus possible with simple dorsiflexion and no distraction, resulting in a possible decrease in complication rates. Level of evidence Retrospective cohort study, Level IV.

  18. Effects of Auditory Distraction on Cognitive Processing of Young Adults

    ERIC Educational Resources Information Center

    LaPointe, Leonard L.; Heald, Gary R.; Stierwalt, Julie A. G.; Kemker, Brett E.; Maurice, Trisha

    2007-01-01

    Objective: The effects of interference, competition, and distraction on cognitive processing are unclearly understood, particularly regarding type and intensity of auditory distraction across a variety of cognitive processing tasks. Method: The purpose of this investigation was to report two experiments that sought to explore the effects of types…

  19. Attention to sound improves auditory reliability in audio-tactile spatial optimal integration.

    PubMed

    Vercillo, Tiziana; Gori, Monica

    2015-01-01

    The role of attention on multisensory processing is still poorly understood. In particular, it is unclear whether directing attention toward a sensory cue dynamically reweights cue reliability during integration of multiple sensory signals. In this study, we investigated the impact of attention in combining audio-tactile signals in an optimal fashion. We used the Maximum Likelihood Estimation (MLE) model to predict audio-tactile spatial localization on the body surface. We developed a new audio-tactile device composed by several small units, each one consisting of a speaker and a tactile vibrator independently controllable by external software. We tested participants in an attentional and a non-attentional condition. In the attentional experiment, participants performed a dual task paradigm: they were required to evaluate the duration of a sound while performing an audio-tactile spatial task. Three unisensory or multisensory stimuli, conflictual or not conflictual sounds and vibrations arranged along the horizontal axis, were presented sequentially. In the primary task participants had to evaluate in a space bisection task the position of the second stimulus (the probe) with respect to the others (the standards). In the secondary task they had to report occasionally changes in duration of the second auditory stimulus. In the non-attentional task participants had only to perform the primary task (space bisection). Our results showed an enhanced auditory precision (and auditory weights) in the auditory attentional condition with respect to the control non-attentional condition. The results of this study support the idea that modality-specific attention modulates multisensory integration.

  20. Impaired laparoscopic performance of novice surgeons due to phone call distraction: a single-centre, prospective study.

    PubMed

    Yang, Cui; Heinze, Julia; Helmert, Jens; Weitz, Juergen; Reissfelder, Christoph; Mees, Soeren Torge

    2017-12-01

    Distractions such as phone calls during laparoscopic surgery play an important role in many operating rooms. The aim of this single-centre, prospective study was to assess if laparoscopic performance is impaired by intraoperative phone calls in novice surgeons. From October 2015 to June 2016, 30 novice surgeons (medical students) underwent a laparoscopic surgery training curriculum including two validated tasks (peg transfer, precision cutting) until achieving a defined level of proficiency. For testing, participants were required to perform these tasks under three conditions: no distraction (control) and two standardised distractions in terms of phone calls requiring response (mild and strong distraction). Task performance was evaluated by analysing time and accuracy of the tasks and response of the phone call. In peg transfer (easy task), mild distraction did not worsen the performance significantly, while strong distraction was linked to error and inefficiency with significantly deteriorated performance (P < 0.05). Precision cutting (difficult task) was not slowed down by mild distraction, but surgical and cognitive errors were significantly increased when participants were distracted (P < 0.05). Compared to mild distraction, participants reported a more severe subjective disturbance when they were diverted by strong distraction (P < 0.05). Our data reveals that phone call distractions result in impaired laparoscopic performance under certain circumstances. To ensure patient safety, phone calls should be avoided as far as possible in operating rooms.

  1. [Passive tactile stimulation and its clinical and neurophysiological repercussions (P300) in blind children with symptoms of attention deficit disorder].

    PubMed

    Serrano-Marugán, Isabel; Herrera, Begoña; Romero, Sara; Nogales, Ramón; Poch-Broto, Joaquín; Quintero, Javier; Ortiz, Tomás

    2014-02-24

    Tactile stimulation is key for the posterior brain re-organization activity and attention processes, however the impact of tactile stimulation on attention deficit disorder (ADD) in blind children remains unexplored. We carried out a study with children having or not ADD (four per group). The subjects have been exposed during six months to tactile stimulation protocol consisting in two daily sessions (morning and afternoon sessions) of 30 minutes each. We have measured the ability to detect an infrequent tactile stimulus, reaction time, latency of P300, sources of brain activity, and ADD clinical symptoms, before and after tactile training. Passive tactile stimulation significantly improves ADD clinical symptoms, particularly attention, behavior and self-control of involuntary movements and tics. In addition, tactile stimulation changes the pattern of brain activity in ADD blind children inducing activity in frontal and occipital areas, which could be associated to a compensation of the attention deficit. Passive tactile stimulation training may improve ADD clinical symptoms and can reorganize the pattern of brain activity in blind ADD children.

  2. The Invisible Universe: A Tactile and Braille Exhibit of Astronomical Images

    NASA Astrophysics Data System (ADS)

    Arcand, Kimberly; Lestition, K.; Watzke, M.; Steel, S.

    2010-01-01

    As part of the "From Earth to the Universe" (FETTU) project, a NASA-funded tactile exhibit for the visually impaired community was launched in July 2009 at the Martin Luther King Library in D.C. The exhibit is part of the global FETTU exhibit, a project of the International Year of Astronomy 2009. The science content of the exhibit includes explanations of our Sun, Eta Carinae, Crab Nebula, Whirlpool Galaxy, and the electromagnetic spectrum, and was adapted from the NASA-funded Braille/tactile book Touch the Invisible Sky. Multiple geographic locations and venue types have been targeted for the displays. The FETTU-tactile exhibit opens a wider door to experiencing and understanding astronomy, bridging a gap in learning. This exhibit is based upon work supported by the National Aeronautics and Space Administration under proposal 08-EPO08-0068 issued through the Science Mission Directorate.

  3. Active tactile sampling by an insect in a step-climbing paradigm

    PubMed Central

    Krause, André F.; Dürr, Volker

    2012-01-01

    Many insects actively explore their near-range environment with their antennae. Stick insects (Carausius morosus) rhythmically move their antennae during walking and respond to antennal touch by repetitive tactile sampling of the object. Despite its relevance for spatial orientation, neither the spatial sampling patterns nor the kinematics of antennation behavior in insects are understood. Here we investigate unrestrained bilateral sampling movements during climbing of steps. The main objectives are: (1) How does the antennal contact pattern relate to particular object features? (2) How are the antennal joints coordinated during bilateral tactile sampling? We conducted motion capture experiments on freely climbing insects, using steps of different height. Tactile sampling was analyzed at the level of antennal joint angles. Moreover, we analyzed contact patterns on the surfaces of both the obstacle and the antenna itself. Before the first contact, both antennae move in a broad, mostly elliptical exploratory pattern. After touching the obstacle, the pattern switches to a narrower and faster movement, caused by higher cycle frequencies and lower cycle amplitudes in all joints. Contact events were divided into wall- and edge-contacts. Wall contacts occurred mostly with the distal third of the flagellum, which is flexible, whereas edge contacts often occurred proximally, where the flagellum is stiff. The movement of both antennae was found to be coordinated, exhibiting bilateral coupling of functionally analogous joints [e.g., left head-scape (HS) joint with right scape-pedicel (SP) joint] throughout tactile sampling. In comparison, bilateral coupling between homologous joints (e.g., both HS joints) was significantly weaker. Moreover, inter-joint coupling was significantly weaker during the contact episode than before. In summary, stick insects show contact-induced changes in frequency, amplitude and inter-joint coordination during tactile sampling of climbed obstacles

  4. Cross-modal tactile-taste interactions in food evaluations

    PubMed Central

    Slocombe, B. G.; Carmichael, D.A.; Simner, J.

    2016-01-01

    Detecting the taste components within a flavoured substance relies on exposing chemoreceptors within the mouth to the chemical components of ingested food. In our paper, we show that the evaluation of taste components can also be influenced by the tactile quality of the food. We first discuss how multisensory factors might influence taste, flavour and smell for both typical and atypical (synaesthetic) populations and we then present two empirical studies showing tactile-taste interactions in the general population. We asked a group of average adults to evaluate the taste components of flavoured food substances, whilst we presented simultaneous cross-sensory visuo-tactile cues within the eating environment. Specifically, we presented foodstuffs between subjects that were otherwise identical but had a rough versus smooth surface, or were served on a rough versus smooth serving-plate. We found no effect of the serving-plate, but we found the rough/smoothness of the foodstuff itself significantly influenced perception: food was rated as significantly more sour if it had a rough (vs. smooth) surface. In modifying taste perception via ostensibly unrelated dimensions, we demonstrate that the detection of tastes within flavours may be influenced by higher level cross-sensory cues. Finally, we suggest that the direction of our cross-sensory associations may speak to the types of hedonic mapping found both in normal multisensory integration, and in the unusual condition of synaesthesia. PMID:26169315

  5. A new tactile gnosis instrument in sensibility testing.

    PubMed

    Rosén, B; Lundborg, G

    1998-01-01

    A new quantitative test instrument for the assessment of tactile gnosis--the ability to identify shapes and textures without vision--is introduced. Introductory investigations of validity and reliability are presented. Fifty-four patients (60 hands) with carpal tunnel syndrome, vibration-induced neuropathy, or nerve repair at distal forearm level, and a matched asymptomatic control group were initially examined. After establishing the cut-off limit for normal tactile gnosis, sensitivity and specificity were calculated to determine the discriminative power of the new instrument. A high sensitivity (1.0) of the new shape/texture identification test was found in the group of patients with nerve repair. Given a cut-off limit, the sensitivity was lower in the groups with vibration-induced neuropathy and carpal tunnel syndrome (0.65 and 0.40, respectively), and the specificity of the test was 0.90 to 0.95. In a second step, a group of 52 patients who had had nerve repair at the distal forearm level were examined. Test-retest reliability was good, with a weighted kappa value of 0.79 to 0.81. Good reliability was also shown in the internal consistency of test items, with a Cronbach alpha value of 0.78. These introductory results indicate that the new shape/texture identification test can be useful in the assessment of tactile gnosis.

  6. Investigating the mechanisms of visually-evoked tactile sensations.

    PubMed

    McKenzie, Kirsten J; Lloyd, Donna M; Brown, Richard J; Plummer, Faye; Poliakoff, Ellen

    2012-01-01

    When attempting to detect a near-threshold signal, participants often incorrectly report the presence of a signal, particularly when a stimulus in a different modality is presented. Here we investigated the effect of prior experience of bimodal visuotactile stimuli on the rate of falsely reported touches in the presence of a light. In Experiment 1, participants made more false alarms in light-present than light-absent trials, despite having no experience of the experimental visuotactile pairing. This suggests that light-evoked false alarms are a consequence of an existing association, rather than one learned during the experiment. In Experiment 2, we sought to manipulate the strength of the association through prior training, using supra-threshold tactile stimuli that were given a high or low association with the light. Both groups still exhibited an increased number of false alarms during light-present trials, however, the low association group made significantly fewer false alarms across conditions, and there was no corresponding group difference in the number of tactile stimuli correctly identified. Thus, while training did not affect the boosting of the tactile signal by the visual stimulus, the low association training affected perceptual decision-making more generally, leading to a lower number of illusory touch reports, independent of the light. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Soft tissue balance changes depending on joint distraction force in total knee arthroplasty.

    PubMed

    Nagai, Kanto; Muratsu, Hirotsugu; Matsumoto, Tomoyuki; Miya, Hidetoshi; Kuroda, Ryosuke; Kurosaka, Masahiro

    2014-03-01

    The influence of joint distraction force on intraoperative soft tissue balance was evaluated using Offset Repo-Tensor® for 78 knees that underwent primary posterior-stabilized total knee arthroplasty. The joint center gap and varus ligament balance were measured between osteotomized surfaces using 20, 40 and 60 lbs of joint distraction force. These values were significantly increased at extension and flexion as the distraction force increased. Furthermore, lateral compartment stiffness was significantly lower than medial compartment stiffness. Thus, larger joint distraction forces led to larger varus ligament balance and joint center gap, because of the difference in soft tissue stiffness between lateral and medial compartments. These findings indicate the importance of the strength of joint distraction force in the assessment of soft tissue balance, especially when using gap-balancing technique. © 2014.

  8. Parathyroid Hormone Therapy Mollifies Radiation-Induced Biomechanical Degradation in Murine Distraction Osteogenesis

    PubMed Central

    Deshpande, Sagar S.; Gallagher, Katherine K.; Donneys, Alexis; Tchanque-Fossuo, Catherine N.; Sarhaddi, Deniz; Nelson, Noah S.; Chepeha, Douglas B.; Buchman, Steven R.

    2015-01-01

    Objective Descriptions of mandibular distraction osteogenesis for tissue replacement after oncologic resection or for defects caused by osteoradionecrosis have been limited. Previous work demonstrated radiation decreases union formation, cellularity and mineral density in mandibular distraction osteogenesis. The authors posit that intermittent systemic administration of parathyroid hormone will serve as a stimulant to cellular function, reversing radiation-induced damage and enhancing bone regeneration. Methods Twenty male Lewis rats were randomly assigned to three groups: group 1 (radiation and distraction osteogenesis, n = 7) and group 2 (radiation, distraction osteogenesis, and parathyroid hormone, n = 5) received a human-equivalent dose of 35 Gy of radiation (human bioequivalent, 70 Gy) fractionated over 5 days. All groups, including group 3 (distraction osteogenesis, n = 8), underwent a left unilateral mandibular osteotomy with bilateral external fixator placement. Distraction osteogenesis was performed at a rate of 0.3 mm every 12 hours to reach a gap of 5.1 mm. Group 2 was injected with parathyroid hormone (60 μg/kg) subcutaneously daily for 3 weeks after the start of distraction osteogenesis. On postoperative day 40, all left hemimandibles were harvested. Biomechanical response parameters were generated. Statistical significance was considered at p ≤ 0.05. Results Parathyroid hormone–treated mandibles had significantly higher failure load and higher yield than did untreated mandibles. However, these values were still significantly lower than those of nonirradiated mandibles. Conclusions The authors have successfully demonstrated the therapeutic efficacy of parathyroid hormone to stimulate and enhance bone regeneration in their irradiated murine mandibular model of distraction osteogenesis. Anabolic regimens of parathyroid hormone, a U.S. Food and Drug Administration–approved drug on formulary, significantly improve outcomes in a model of

  9. Interaction of Perceptual Grouping and Crossmodal Temporal Capture in Tactile Apparent-Motion

    PubMed Central

    Chen, Lihan; Shi, Zhuanghua; Müller, Hermann J.

    2011-01-01

    Previous studies have shown that in tasks requiring participants to report the direction of apparent motion, task-irrelevant mono-beeps can “capture” visual motion perception when the beeps occur temporally close to the visual stimuli. However, the contributions of the relative timing of multimodal events and the event structure, modulating uni- and/or crossmodal perceptual grouping, remain unclear. To examine this question and extend the investigation to the tactile modality, the current experiments presented tactile two-tap apparent-motion streams, with an SOA of 400 ms between successive, left-/right-hand middle-finger taps, accompanied by task-irrelevant, non-spatial auditory stimuli. The streams were shown for 90 seconds, and participants' task was to continuously report the perceived (left- or rightward) direction of tactile motion. In Experiment 1, each tactile stimulus was paired with an auditory beep, though odd-numbered taps were paired with an asynchronous beep, with audiotactile SOAs ranging from −75 ms to 75 ms. Perceived direction of tactile motion varied systematically with audiotactile SOA, indicative of a temporal-capture effect. In Experiment 2, two audiotactile SOAs—one short (75 ms), one long (325 ms)—were compared. The long-SOA condition preserved the crossmodal event structure (so the temporal-capture dynamics should have been similar to that in Experiment 1), but both beeps now occurred temporally close to the taps on one side (even-numbered taps). The two SOAs were found to produce opposite modulations of apparent motion, indicative of an influence of crossmodal grouping. In Experiment 3, only odd-numbered, but not even-numbered, taps were paired with auditory beeps. This abolished the temporal-capture effect and, instead, a dominant percept of apparent motion from the audiotactile side to the tactile-only side was observed independently of the SOA variation. These findings suggest that asymmetric crossmodal grouping leads to an

  10. Tactile spatial resolution in blind braille readers.

    PubMed

    Van Boven, R W; Hamilton, R H; Kauffman, T; Keenan, J P; Pascual-Leone, A

    2000-06-27

    To determine if blind people have heightened tactile spatial acuity. Recently, studies using magnetic source imaging and somatosensory evoked potentials have shown that the cortical representation of the reading fingers of blind Braille readers is expanded compared to that of fingers of sighted subjects. Furthermore, the visual cortex is activated during certain tactile tasks in blind subjects but not sighted subjects. The authors hypothesized that the expanded cortical representation of fingers used in Braille reading may reflect an enhanced fidelity in the neural transmission of spatial details of a stimulus. If so, the quantitative limit of spatial acuity would be superior in blind people. The authors employed a grating orientation discrimination task in which threshold performance is accounted for by the spatial resolution limits of the neural image evoked by a stimulus. The authors quantified the psychophysical limits of spatial acuity at the middle and index fingers of 15 blind Braille readers and 15 sighted control subjects. The mean grating orientation threshold was significantly (p = 0.03) lower in the blind group (1.04 mm) compared to the sighted group (1.46 mm). The self-reported dominant reading finger in blind subjects had a mean grating orientation threshold of 0.80 mm, which was significantly better than other fingers tested. Thresholds at non-Braille reading fingers in blind subjects averaged 1.12 mm, which were also superior to sighted subjects' performances. Superior tactile spatial acuity in blind Braille readers may represent an adaptive, behavioral correlate of cortical plasticity.

  11. Ilizarov distraction-lengthening in congenital anomalies of the upper limb.

    PubMed

    Hülsbergen-Krüger, S; Preisser, P; Partecke, B D

    1998-04-01

    Nine patients underwent Ilizarov distraction-lengthening for congenital anomalies. All were late cases and had undergone other procedures. In five radial club hand patients with very short forearms, we achieved an average 5.8 cm increase in length with each distraction cycle. In two patients with symbrachydactyly of the cleft hand type, we achieved pinch grip between a radial and an ulnar digit by lengthening the short ray. Another case of the monodactyly type in which we tried to lengthen three transplanted proximal toe phalanges ended in failure. A soft tissue distraction was attempted in a case of camptodactyly but failed. We report the problems we encountered and suggest some solutions.

  12. Background distraction during vertical solid and character line bisections.

    PubMed

    Rodriguez, Julio A; Lamb, Damon G; Salazar, Liliana; Correa, Lauren N; Mosquera, Diana M; Schwartz, Zared J; Cohen, Ronald A; Falchook, Adam D; Heilman, Kenneth M

    2018-04-04

    Background-objectives: When vertical lines are positioned above or below the center of the page, line bisection deviates toward the center of the page, suggesting that the edges of the page distract the allocation of attention to the line. A letter-character line (LCL) bisection requires both global and focal attention, to identify the target letter closest to the line's center. If more focal and less global attention is allocated to a LCL, more global attentional resources may be available and inadvertently allocated to the page. Alternatively, if the allocation of focal attention to a LCL inhibits global attentional processing, there may be less distraction by the page. Twenty-four healthy adults (12 older) bisected vertical solid and character lines centered, or positioned closer to the top or bottom of the page. There was no difference between bisection of solid and character lines centered on the page. Page-related deviations were greater with character lines than solid line bisections, and greater for lines positioned toward the top than the bottom of the page. With lines positioned toward the top, the older participants' attempted bisections were higher than those of the younger participants. These results suggest that the allocation of focal attention increases global attentional distractibility and that global-background attentional distraction is greater when the vertical lines are placed in the upper part of the page. Older participants appeared to be less distracted when lines were placed toward the top of the page, but the reason for this age difference requires further research.

  13. The Tactile Ethics of Soft Robotics: Designing Wisely for Human-Robot Interaction.

    PubMed

    Arnold, Thomas; Scheutz, Matthias

    2017-06-01

    Soft robots promise an exciting design trajectory in the field of robotics and human-robot interaction (HRI), promising more adaptive, resilient movement within environments as well as a safer, more sensitive interface for the objects or agents the robot encounters. In particular, tactile HRI is a critical dimension for designers to consider, especially given the onrush of assistive and companion robots into our society. In this article, we propose to surface an important set of ethical challenges for the field of soft robotics to meet. Tactile HRI strongly suggests that soft-bodied robots balance tactile engagement against emotional manipulation, model intimacy on the bonding with a tool not with a person, and deflect users from personally and socially destructive behavior the soft bodies and surfaces could normally entice.

  14. Influence of positive distractions on children in two clinic waiting areas.

    PubMed

    Pati, Debajyoti; Nanda, Upali

    2011-01-01

    To examine the influence of positive distraction on the behavior and activity of children in two clinic waiting areas. People spend a considerable proportion of time waiting in hospitals. Studies show that the quality of waiting environments influences the perception of quality of care and caregivers, that perception of waiting time is a better indicator of patient satisfaction than actual waiting time, and that the waiting environment contributes to the perception of wait time. In fact, the attractiveness of the physical environment in waiting areas has been shown to be significantly associated with higher perceived quality of care, less anxiety, and higher reported positive interaction with staff. Can positive distractions in waiting areas improve the waiting experience, as indicated by the behavior and activities of children waiting for treatment? Five distraction conditions were randomly introduced in the waiting area of the dental and cardiac clinics of a major pediatric tertiary care center through a single plasma screen intervention. The attention, behavior, and activities of waiting children were recorded. Data on 158 pediatric patients were collected over 12 days during December 2008 and January 2009. Data analysis shows that the introduction of distraction conditions was associated with more calm behavior and less fine and gross movement, suggesting significant calming effects associated with the distraction conditions. Data also suggest that positive distraction conditions are significant attention grabbers and could be an important contributor to improving the waiting experience for children in hospitals by improving environmental attractiveness.

  15. Anticipation increases tactile stimulus processing in the ipsilateral primary somatosensory cortex.

    PubMed

    van Ede, Freek; de Lange, Floris P; Maris, Eric

    2014-10-01

    Stimulus anticipation improves perception. To account for this improvement, we investigated how stimulus processing is altered by anticipation. In contrast to a large body of previous work, we employed a demanding perceptual task and investigated sensory responses that occur beyond early evoked activity in contralateral primary sensory areas: Stimulus-induced modulations of neural oscillations. For this, we recorded magnetoencephalography in 19 humans while they performed a cued tactile identification task involving the identification of either a proximal or a distal stimulation on the fingertips. We varied the cue-target interval between 0 and 1000 ms such that tactile targets occurred at various degrees of anticipation. This allowed us to investigate the influence of anticipation on stimulus processing in a parametric fashion. We observed that anticipation increases the stimulus-induced response (suppression of beta-band oscillations) originating from the ipsilateral primary somatosensory cortex. This occurs in the period in which the tactile memory trace is analyzed and is correlated with the anticipation-induced improvement in tactile perception. We propose that this ipsilateral response indicates distributed processing across bilateral primary sensory cortices, of which the extent increases with anticipation. This constitutes a new and potentially important mechanism contributing to perception and its improvement following anticipation. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  16. Compact Tactile Sensors for Robot Fingers

    NASA Technical Reports Server (NTRS)

    Martin, Toby B.; Lussy, David; Gaudiano, Frank; Hulse, Aaron; Diftler, Myron A.; Rodriguez, Dagoberto; Bielski, Paul; Butzer, Melisa

    2004-01-01

    Compact transducer arrays that measure spatial distributions of force or pressure have been demonstrated as prototypes of tactile sensors to be mounted on fingers and palms of dexterous robot hands. The pressure- or force-distribution feedback provided by these sensors is essential for the further development and implementation of robot-control capabilities for humanlike grasping and manipulation.

  17. Transpalatal distraction for the management of maxillary constriction in pediatric patients.

    PubMed

    Adolphs, Nicolai; Ernst, Nicole; Hoffmeister, Bodo; Raguse, Jan-Dirk

    2015-01-01

    The management of severe maxillary constriction can be challenging. For that purpose surgically assisted maxillary expansion by transpalatal distraction (TPD) can typically be recommended after skeletal maturity. However in selected cases bone borne transpalatal distraction devices can contribute to improve maxillary constriction considerably earlier already during mixed dentition. To assess the possibility of bone borne transpalatal distraction in pediatric patients. Clinical paper. Since 2010 TPD has been applied to six pediatric patients during mixed dentition when severe maxillary constriction was present and conventional orthodontic widening has already failed. Individually selected devices (Surgitec, Belgium) were inserted in general anaesthesia and distraction was performed according to well known parameters. Maxillary constriction could be improved in all six patients without any drawbacks by bone borne devices during mixed dentition. Skeletal conditions were obviously improved for subsequent orthodontic or orthognathic therapy without functional impairment. Follow-up is up to 36 months after device removal. Transpalatal Distraction is recommendable in selected pediatric patients if massive growth disturbance is present or has to be expected. TPD allows for individually adapted maxillary expansion by selection and positioning of appropriate devices in combination with intraoperative testing of maxillary movements and controlled bone removal.

  18. Hearing shapes our perception of time: temporal discrimination of tactile stimuli in deaf people.

    PubMed

    Bolognini, Nadia; Cecchetto, Carlo; Geraci, Carlo; Maravita, Angelo; Pascual-Leone, Alvaro; Papagno, Costanza

    2012-02-01

    Confronted with the loss of one type of sensory input, we compensate using information conveyed by other senses. However, losing one type of sensory information at specific developmental times may lead to deficits across all sensory modalities. We addressed the effect of auditory deprivation on the development of tactile abilities, taking into account changes occurring at the behavioral and cortical level. Congenitally deaf and hearing individuals performed two tactile tasks, the first requiring the discrimination of the temporal duration of touches and the second requiring the discrimination of their spatial length. Compared with hearing individuals, deaf individuals were impaired only in tactile temporal processing. To explore the neural substrate of this difference, we ran a TMS experiment. In deaf individuals, the auditory association cortex was involved in temporal and spatial tactile processing, with the same chronometry as the primary somatosensory cortex. In hearing participants, the involvement of auditory association cortex occurred at a later stage and selectively for temporal discrimination. The different chronometry in the recruitment of the auditory cortex in deaf individuals correlated with the tactile temporal impairment. Thus, early hearing experience seems to be crucial to develop an efficient temporal processing across modalities, suggesting that plasticity does not necessarily result in behavioral compensation.

  19. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model

    PubMed Central

    Hughes, Matthew; Papadakos, Nikolaos; Bishop, Tim; Bernard, Jason

    2018-01-01

    Introduction: Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Methods: Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar spine underwent bilateral pedicle distraction at L4. A pedicle channel was drilled between the superior articular process and transverse process into the vertebral body. The pedicles underwent osteotomy at the midpoint. Screws were inserted bilaterally and fixated distraction of 0 mm, 2 mm, 4 mm and 6 mm. CT images were taken at each level of distraction. Foramen area was measured in the sagittal plane at L3/4. Spinal canal area was measured at L4 in the axial images. The cadaver was used to evaluate safety of osteotomy and soft tissue interactions preventing distraction. Statistical analysis was by student paired t-test and Pearson rank test. Results: Increasing distraction led to greater Spinal canal area. From 4.27 cm2 to 5.72 cm2 (p = 0.002) with 6 mm distraction. A Maximal increase of 34.1%. Vertebral foramen area also increased with increasing pedicle distraction. From 2.43 cm2 to 3.22 cm2 (p = 0.022) with 6 mm distraction. A maximal increase of 32.3%. The cadaver spinal canal increased in area by 21.7%. The vertebral foramen increased in area by 36.2% (left) and 22.6% (right). Discussion: For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction. PMID:29727270

  20. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model.

    PubMed

    Hughes, Matthew; Papadakos, Nikolaos; Bishop, Tim; Bernard, Jason

    2018-01-01

    Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar spine underwent bilateral pedicle distraction at L4. A pedicle channel was drilled between the superior articular process and transverse process into the vertebral body. The pedicles underwent osteotomy at the midpoint. Screws were inserted bilaterally and fixated distraction of 0 mm, 2 mm, 4 mm and 6 mm. CT images were taken at each level of distraction. Foramen area was measured in the sagittal plane at L3/4. Spinal canal area was measured at L4 in the axial images. The cadaver was used to evaluate safety of osteotomy and soft tissue interactions preventing distraction. Statistical analysis was by student paired t-test and Pearson rank test. Increasing distraction led to greater Spinal canal area. From 4.27 cm 2 to 5.72 cm 2 (p = 0.002) with 6 mm distraction. A Maximal increase of 34.1%. Vertebral foramen area also increased with increasing pedicle distraction. From 2.43 cm 2 to 3.22 cm 2 (p = 0.022) with 6 mm distraction. A maximal increase of 32.3%. The cadaver spinal canal increased in area by 21.7%. The vertebral foramen increased in area by 36.2% (left) and 22.6% (right). For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction. © The Authors, published by EDP Sciences, 2018.