Sample records for tandem degradation methods

  1. Liquid chromatography/tandem mass spectrometry study of forced degradation of azilsartan medoxomil potassium.

    PubMed

    Swain, Debasish; Patel, Prinesh N; Palaniappan, Ilayaraja; Sahu, Gayatri; Samanthula, Gananadhamu

    2015-08-15

    Azilsartan medoxomil potassium (AZM) is a new antihypertensive drug introduced in the year 2011. The presence of degradation products not only affects the quality, but also the safety aspects of the drug. Thus, it is essential to develop an efficient analytical method which could be useful to selectively separate and identify the degradation products of azilsartan medoxomil potassium. AZM was subjected to forced degradation under hydrolytic (acid, base and neutral), oxidative, photolytic and thermal stress conditions. Separation of the drug and degradation products was achieved by a liquid chromatography (LC) method using an Acquity UPLC(®) C18 CSH column with mobile phase consisting of 0.02% trifluoroacetic acid and acetonitrile using a gradient method. Identification and characterization of the degradation products was carried out using LC/electrospray ionization quadrupole time-of-flight mass spectrometry (ESI-QTOFMS). A total of five degradation products (DP 1 to DP 5) were formed under various stress conditions and their structures were proposed with the help of tandem mass spectrometry (MS/MS) experiments and accurate mass data. A common degradation product (DP 4) was observed under all the degradation conditions. DP 1, DP 2 and DP 5 were observed under acid hydrolytic conditions whereas DP 3 was observed under alkaline conditions. AZM was found to degrade under hydrolytic, oxidative and photolytic stress conditions. The structures of all the degradation products were proposed. The degradation pathway for the formation of degradation products was also hypothesized. A selective method was developed to quantify the drug in the presence of degradation products which is useful to monitor the quality of AZM. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Characterization of a low-level unknown isomeric degradation product using an integrated online-offline top-down tandem mass spectrometry platform.

    PubMed

    Yu, Xiang; Warme, Christopher; Lee, Dinah; Zhang, Jing; Zhong, Wendy

    2013-10-01

    An integrated online-offline platform was developed combining automated online LC-MS fraction collection, continuous accumulation of selected ions (CASI), and offline top-down electron capture dissociation (ECD) tandem mass spectrometry experiments to identify a low-level, unknown isomeric degradant in a formulated drug product during an accelerated stability study. By identifying the diagnostic ions of the isoaspartic acid (isoAsp), the top-down ECD experiment showed that the Asp9 in exenatide was converted to isoAsp9 to form the unknown isomeric degradant. The platform described here provides an accurate, straightforward, and low limit of detection method for the analysis of Asp isomerization as well as other potential low-level degradants in therapeutic polypeptides and proteins. It is especially useful for unstable and time-sensitive degradants and impurities.

  3. Residue analysis and degradation studies of fenbuconazole and myclobutanil in strawberry by chiral high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Hu; Wang, Xinquan; Qian, Mingrong; Wang, Xiangyun; Xu, Hao; Xu, Mingfei; Wang, Qiang

    2011-11-23

    A simple and sensitive enantioselective method for the determination of fenbuconazole and myclobutanil in strawberry was developed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Fenbuconazole and myclobutanil residues in strawberry were extracted with acetonitrile containing 1% acetic acid, and an aliquot was cleaned up with PSA (primary and secondary amine) and C(18) sorbent. The direct resolution of fenbuconazole and myclobutanil enantiomers was performed on a cellulose tris (3,5-dimethylphenylcarbamate) column using acetonitrile-0.1% formic acid solution (60:40, v/v) as the mobile phase. Quantification was achieved using matrix-matched standard calibration curves, and the limits of quantification for fenbuconazole and myclobutanil enantiomers in strawberry were both 2 μg/kg. The method was successfully utilized to investigate the probable enantioselective degradation of fenbuconazole and myclobutanil in strawberry. The results showed that the degradation of the fenbuconazole and myclobutanil enantiomers in strawberry followed pseudofirst-order kinetics (R(2) > 0.97). The results from this study revealed that the degradation of fenbuconazole in strawberry was not enantioselective, while the degradation of myclobutanil was enantioselective, and the (+)-myclobutanil showed a faster degradation than (-)-myclobutanil in strawberry, resulting in the relative enrichment of (-)-myclobutanil in residue. The results could provide a reference to fully evaluate the risks of these two fungicides.

  4. A novel automated hydrophilic interaction liquid chromatography method using diode-array detector/electrospray ionization tandem mass spectrometry for analysis of sodium risedronate and related degradation products in pharmaceuticals.

    PubMed

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2014-10-24

    A simple, sensitive and fast hydrophilic interaction liquid chromatography (HILIC) method using ultraviolet diode-array detector (UV-DAD)/electrospray ionization tandem mass spectrometry was developed for the automated high performance liquid chromatography (HPLC) determination of sodium risedronate (SR) and its degradation products in new pharmaceuticals. The chromatographic separations were performed on Ascentis Express HILIC 2.7μm (150mm×2.1mm, i.d.) stainless steel column (fused core). The mobile phase consisted of formate buffer solution (pH 3.4; 0.03M)/acetonitrile 42:58 and 45:55 (v/v) for granules for oral solution and effervescent tablet analysis, respectively, at a flow-rate of 0.2mL/min, setting the wavelength at 262nm. Stability characteristics of SR were evaluated by performing stress test studies. The main degradation product formed under oxidation conditions corresponding to sodium hydrogen (1-hydroxy-2-(1-oxidopyridin-3-yl)-1-phosphonoethyl)phosphonate was characterized by high performance liquid chromatography-electrospray ionization-mass tandem mass spectrometry (HPLC-ESI-MS/MS). The validation parameters such as linearity, sensitivity, accuracy, precision and selectivity were found to be highly satisfactory. Linear responses were observed in standard and in fortified placebo solutions. Intra-day precision (relative standard deviation, RSD) was ≤1.1% for peak area and ≤0.2% for retention times (tR) without significant differences between intra- and inter-day data. Recovery studies showed good results for all the examined compounds (from 98.7 to 101.0%) with RSD ranging from 0.6 to 0.7%. The limits of detection (LOD) and quantitation (LOQ) were 1 and 3ng/mL, respectively. The high stability of standard and sample solutions at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed stability indicating

  5. Development of a pressurized liquid extraction-solid-phase extraction followed by liquid chromatography-electrospray ionization tandem mass spectrometry method for the quantitative determination of benzoxazolinones and their degradation products in agricultural soil.

    PubMed

    Villagrasa, M; Guillamón, M; Navarro, A; Eljarrat, E; Barceló, D

    2008-02-01

    A new analytical method for the quantitative determination of benzoxazolinones and their degradation products in agricultural soils based on the use of pressurized liquid extraction (PLE) followed by solid-phase extraction (SPE) and then instrumental determination using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) is described. Using this method, the characterization, separation and quantitative detection of a mixture of two benzoxazolinones, benzoxazolin-2-one (BOA) and 6-methoxybenzoxazolin-2-one (MBOA) and their degradation products, 2-aminophenol (APH), N-(2-hydroxyphenyl)malonamic acid (HMPMA), 2-amino-3-H-phenoxazin-3-one (APO), 9-methoxy-2-amino-3-H-phenoxazin-3-one (AMPO), 2-acetylamino-3-H-phenoxazin-3-one (AAPO) and 2-acetylamino-9-methoxy-2-amino-3-H-phenoxazin-3-one (AAMPO) was achieved. The complete LC-ESI-MS-MS precursor-product ion fragmentation pathways for the degradation products of benzoxazolinones are described for the first time. Quantitative analysis was done in the multiple reaction mode using two specific combinations of precursor-product ion transitions for each compound. The optimized method was quality assessed by the measure of parameter as recovery, linearity, sensitivity, repeatability and reproducibility. Recoveries of the analytes ranged from 53 to 123%. The developed method offered improvements to the sensitivity as compared with our previously LC-MS method, with detection limits down to 2.4-21 ng/g of dry weight. This achievement allows us to identify and quantify for the first time degradation products of benzoxazolinones in real agricultural soil samples. Analytes were found in the range of 20.6-149 ng/g dry weight.

  6. Quantitative determination of antidepressants and their select degradates by liquid chromatography/electrospray ionization tandem mass spectrometry in biosolids destined for land application.

    PubMed

    Niemi, Lydia M; Stencel, Katherine A; Murphy, Madigan J; Schultz, Melissa M

    2013-08-06

    Antidepressants are one of the most widely dispensed classes of pharmaceuticals in the United States. As wastewater treatment plants are a primary source of pharmaceuticals in the environment, the use of biosolids as fertilizer is a potential route for antidepressants to enter the terrestrial environment. A microsolvent extraction method, utilizing green chemistry, was developed for extraction of the target antidepressants and degradation products from biosolids, or more specifically lagoon biosolids. Liquid chromatography/tandem mass spectrometry was used for quantitative determination of antidepressants in the lagoon biosolid extracts. Recoveries from matrix spiking experiments for the individual antidepressants had an average of 96%. The limits of detection for antidepressant pharmaceuticals and degradates ranged from 0.36 to 8.0 ng/kg wet weight. The method was applied to biosolids destined for land application. A suite of antidepressants was consistently detected in the lagoon biosolid samples, and thus antidepressants are being introduced to terrestrial environments through the land application of these biosolids. Sertraline and norsertraline were the most abundant antidepressant and degradation product detected in the biosolid samples. Detected, individual antidepressant concentrations ranged from 8.5 ng/kg (norfluoxetine) to 420 ng/kg wet weight (norsertraline).

  7. High-performance liquid chromatography/high-resolution multiple stage tandem mass spectrometry using negative-ion-mode hydroxide-doped electrospray ionization for the characterization of lignin degradation products.

    PubMed

    Owen, Benjamin C; Haupert, Laura J; Jarrell, Tiffany M; Marcum, Christopher L; Parsell, Trenton H; Abu-Omar, Mahdi M; Bozell, Joseph J; Black, Stuart K; Kenttämaa, Hilkka I

    2012-07-17

    In the search for a replacement for fossil fuel and the valuable chemicals currently obtained from crude oil, lignocellulosic biomass has become a promising candidate as an alternative biorenewable source for crude oil. Hence, many research efforts focus on the extraction, degradation, and catalytic transformation of lignin, hemicellulose, and cellulose. Unfortunately, these processes result in the production of very complex mixtures. Further, while methods have been developed for the analysis of mixtures of oligosaccharides, this is not true for the complex mixtures generated upon degradation of lignin. For example, high-performance liquid chromatography/multiple stage tandem mass spectrometry (HPLC/MS(n)), a tool proven to be invaluable in the analysis of complex mixtures derived from many other biopolymers, such as proteins and DNA, has not been implemented for lignin degradation products. In this study, we have developed an HPLC separation method for lignin degradation products that is amenable to negative-ion-mode electrospray ionization (ESI doped with NaOH), the best method identified thus far for ionization of lignin-related model compounds without fragmentation. The separated and ionized compounds are then analyzed by MS(3) experiments to obtain detailed structural information while simultaneously performing high-resolution measurements to determine their elemental compositions in the two parts of a commercial linear quadrupole ion trap/Fourier-transform ion cyclotron resonance mass spectrometer. A lignin degradation product mixture was analyzed using this method, and molecular structures were proposed for some components. This methodology significantly improves the ability to analyze complex product mixtures that result from degraded lignin.

  8. Probing Photocurrent Nonuniformities in the Subcells of Monolithic Perovskite/Silicon Tandem Solar Cells.

    PubMed

    Song, Zhaoning; Werner, Jérémie; Shrestha, Niraj; Sahli, Florent; De Wolf, Stefaan; Niesen, Björn; Watthage, Suneth C; Phillips, Adam B; Ballif, Christophe; Ellingson, Randy J; Heben, Michael J

    2016-12-15

    Perovskite/silicon tandem solar cells with high power conversion efficiencies have the potential to become a commercially viable photovoltaic option in the near future. However, device design and optimization is challenging because conventional characterization methods do not give clear feedback on the localized chemical and physical factors that limit performance within individual subcells, especially when stability and degradation is a concern. In this study, we use light beam induced current (LBIC) to probe photocurrent collection nonuniformities in the individual subcells of perovskite/silicon tandems. The choices of lasers and light biasing conditions allow efficiency-limiting effects relating to processing defects, optical interference within the individual cells, and the evolution of water-induced device degradation to be spatially resolved. The results reveal several types of microscopic defects and demonstrate that eliminating these and managing the optical properties within the multilayer structures will be important for future optimization of perovskite/silicon tandem solar cells.

  9. A method for addressing differences in concentrations of fipronil and three degradates obtained by two different laboratory methods

    USGS Publications Warehouse

    Crawford, Charles G.; Martin, Jeffrey D.

    2017-07-21

    In October 2012, the U.S. Geological Survey (USGS) began measuring the concentration of the pesticide fipronil and three of its degradates (desulfinylfipronil, fipronil sulfide, and fipronil sulfone) by a new laboratory method using direct aqueous-injection liquid chromatography tandem mass spectrometry (DAI LC–MS/MS). This method replaced the previous method—in use since 2002—that used gas chromatography/mass spectrometry (GC/MS). The performance of the two methods is not comparable for fipronil and the three degradates. Concentrations of these four chemical compounds determined by the DAI LC–MS/MS method are substantially lower than the GC/MS method. A method was developed to correct for the difference in concentrations obtained by the two laboratory methods based on a methods comparison field study done in 2012. Environmental and field matrix spike samples to be analyzed by both methods from 48 stream sites from across the United States were sampled approximately three times each for this study. These data were used to develop a relation between the two laboratory methods for each compound using regression analysis. The relations were used to calibrate data obtained by the older method to the new method in order to remove any biases attributable to differences in the methods. The coefficients of the equations obtained from the regressions were used to calibrate over 16,600 observations of fipronil, as well as the three degradates determined by the GC/MS method retrieved from the USGS National Water Information System. The calibrated values were then compared to over 7,800 observations of fipronil and to the three degradates determined by the DAI LC–MS/MS method also retrieved from the National Water Information System. The original and calibrated values from the GC/MS method, along with measures of uncertainty in the calibrated values and the original values from the DAI LC–MS/MS method, are provided in an accompanying data release.

  10. Investigation of the persistence of nerve agent degradation analytes on surfaces through wipe sampling and detection with ultrahigh performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Willison, Stuart A

    2015-01-20

    The persistence of chemical warfare nerve agent degradation analytes on surfaces is important, from indicating the presence of nerve agent on a surface to guiding environmental restoration of a site after a release. Persistence was investigated for several chemical warfare nerve agent degradation analytes on indoor surfaces and presents an approach for wipe sampling of surfaces, followed by wipe extraction and liquid chromatography-tandem mass spectrometry detection. Commercially available wipe materials were investigated to determine optimal wipe recoveries. Tested surfaces included porous/permeable (vinyl tile, painted drywall, and wood) and largely nonporous/impermeable (laminate, galvanized steel, and glass) surfaces. Wipe extracts were analyzed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). UPLC provides a separation of targeted degradation analytes in addition to being nearly four times faster than high-performance liquid chromatography, allowing for greater throughput after a large-scale contamination incident and subsequent remediation events. Percent recoveries from nonporous/impermeable surfaces were 60-103% for isopropyl methylphosphonate (IMPA), GB degradate; 61-91% for ethyl methylphosphonate (EMPA), VX degradate; and 60-98% for pinacolyl methylphosphonate (PMPA), GD degradate. Recovery efficiencies for methyl phosphonate (MPA), nerve agent degradate, and ethylhydrogen dimethylphosphonate (EHDMAP), GA degradate, were lower, perhaps due to matrix effects. Diisopropyl methylphosphonate, GB impurity, was not recovered from surfaces. The resulting detection limits for wipe extracts were 0.065 ng/cm(2) for IMPA, 0.079 ng/cm(2) for MPA, 0.040 ng/cm(2) for EMPA, 0.078 ng/cm(2) for EHDMAP, and 0.013 ng/cm(2) for PMPA. The data indicate that laboratories may hold wipe samples for up to 30 days prior to analysis. Target analytes were observed to persist on surfaces for at least 6 weeks.

  11. Determination of fluorotelomer alcohols and their degradation products in biosolids-amended soils and plants using ultra-high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Zhang, Hongna; Wen, Bei; Hu, Xiaoyu; Wu, Yali; Luo, Lei; Chen, Zien; Zhang, Shuzhen

    2015-07-24

    Degradation of fluorotelomer alcohols (FTOHs) was recognized as an additional source of perfluorocarboxylic acids (PFCAs). Quantification of FTOHs and their degradation products can help shed light on the sources and fates of PFCAs in the environment. In this study, an analytical method was developed for the determination of 6:2 and 8:2 FTOHs, and their degradation products of poly- and perfluorinated acids, including fluorotelomer saturated and unsaturated carboxylic acids (FTCAs and FTUCAs), secondary polyfluorinated alcohols and PFCAs in biosolids-amended soils and plants using ultra-high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). The extract efficiencies of different methods including ethyl acetate and methanol (MeOH) for FTOHs and acetonitrile, MeOH, methyl tert-butyl ether (MTBE), NaOH-MeOH and NaOH-MTBE for poly- and perfluorinated acids were tested. The results showed that 6:2 and 8:2 FTOHs and their degradation products could be simultaneously and satisfactorily extracted by MeOH, cleaned up by Envi-Carb graphitized carbon and solid phase extraction, respectively, and determined by UPLC-MS/MS separately. NaOH in the extractant caused the conversion of 6:2 FTCA and 8:2 FTCA into the corresponding FTUCAs. The selected methods have matrix recoveries ranged from 52% to 102%, and detection limits of 0.01-0.46ng/g dry weight for FTOHs and their degradation products in soil and plant. The optimized method was applied successfully to quantify FTOHs and their degradation products in two biosolids-amended soils and plants. The total concentrations of FTOHs in the soils were 44.1±5.8 and 82.6±7.1ng/g, and in plants tissues 3.58±0.25 and 8.33±0.66ng/g. The total concentrations of poly- and perfluorinated acids in the soils were 168.0±13.2 and 349.6±11.2ng/g, and in plants tissues 78.0±6.4 and 75.5±5.3ng/g. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Enantioseparation of Imazalil and Monitoring of Its Enantioselective Degradation in Apples and Soils Using Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Li, Runan; Dong, Fengshou; Xu, Jun; Liu, Xingang; Wu, Xiaohu; Pan, Xinglu; Tao, Yan; Chen, Zenglong; Zheng, Yongquan

    2017-04-26

    Imazalil is a widely used systemic chiral fungicide that is still being employed as a racemic mixture without distinguishing the difference between enantiomers, which often leads to its inaccurate risk assessment. In this study, a robust and highly sensitive chiral separation method was developed for imazalil enantiomers by ultrahigh-performance liquid chromatography-tandem mass spectrometry and was further applied to study the degradation dynamics of imazalil enantiomers in apples and field soils at three sites in China. The baseline enantioseparation for imazalil was achieved within 3.5 min on a Lux Cellulose-2 (CCMPC) column with acetonitrile (ACN)/water (65:35, v/v) with a mobile phase at 0.5 mL/min flow rate and a column temperature of 20 °C. The limit of quantitation (LOQ) for each enantiomer was <0.60 μg/kg, with a baseline resolution of approximately 1.75. The research showed that (S)-(+)-imazalil degraded more rapidly than (R)-(-)-imazalil in Gala apples, whereas (R)-(-)-imazalil preferentially degraded in Golden Delicious apples. No significant enantioselectivity was observed in OBIR-2T-47 apples and field soils from the three sites. Results of this study provide useful references for risk assessment and the rational use of imazalil in further agricultural produce practice.

  13. Incomplete proteasomal degradation of green fluorescent proteins in the context of tandem fluorescent protein timers

    PubMed Central

    Khmelinskii, Anton; Meurer, Matthias; Ho, Chi-Ting; Besenbeck, Birgit; Füller, Julia; Lemberg, Marius K.; Bukau, Bernd; Mogk, Axel; Knop, Michael

    2016-01-01

    Tandem fluorescent protein timers (tFTs) report on protein age through time-dependent change in color, which can be exploited to study protein turnover and trafficking. Each tFT, composed of two fluorescent proteins (FPs) that differ in maturation kinetics, is suited to follow protein dynamics within a specific time range determined by the maturation rates of both FPs. So far, tFTs have been constructed by combining slower-maturing red fluorescent proteins (redFPs) with the faster-maturing superfolder green fluorescent protein (sfGFP). Toward a comprehensive characterization of tFTs, we compare here tFTs composed of different faster-maturing green fluorescent proteins (greenFPs) while keeping the slower-maturing redFP constant (mCherry). Our results indicate that the greenFP maturation kinetics influences the time range of a tFT. Moreover, we observe that commonly used greenFPs can partially withstand proteasomal degradation due to the stability of the FP fold, which results in accumulation of tFT fragments in the cell. Depending on the order of FPs in the timer, incomplete proteasomal degradation either shifts the time range of the tFT toward slower time scales or precludes its use for measurements of protein turnover. We identify greenFPs that are efficiently degraded by the proteasome and provide simple guidelines for the design of new tFTs. PMID:26609072

  14. Wipe selection for the analysis of surface materials containing chemical warfare agent nitrogen mustard degradation products by ultra-high pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Willison, Stuart A

    2012-12-28

    Degradation products arising from nitrogen mustard chemical warfare agent were deposited on common urban surfaces and determined via surface wiping, wipe extraction, and liquid chromatography–tandem mass spectrometry detection. Wipes investigated included cotton gauze, glass fiber filter, non-woven polyester fiber and filter paper, and surfaces included several porous (vinyl tile, painted drywall, wood) and mostly non-porous (laminate, galvanized steel, glass) surfaces. Wipe extracts were analyzed by ultra-high pressure liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) and compared with high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) results. An evaluation of both techniques suggests UPLC–MS/MS provides a quick and sensitive analysis of targeted degradation products in addition to being nearly four times faster than a single HPLC run, allowing for greater throughput during a wide-spread release concerning large-scale contamination and subsequent remediation events. Based on the overall performance of all tested wipes, filter paper wipes were selected over other wipes because they did not contain interferences or native species (TEA and DEA) associated with the target analytes, resulting in high percent recoveries and low background levels during sample analysis. Other wipes, including cotton gauze, would require a pre-cleaning step due to the presence of large quantities of native species or interferences of the targeted analytes. Percent recoveries obtained from a laminate surface were 47–99% for all nitrogen mustard degradation products. The resulting detection limits achieved from wipes were 0.2 ng/cm(2) for triethanolamine (TEA), 0.03 ng/cm(2) for N-ethyldiethanolamine (EDEA), 0.1 ng/cm(2) for N-methyldiethanolamine (MDEA), and 0.1 ng/cm(2) for diethanolamine (DEA).

  15. Trace level determination of selected organophosphorus pesticides and their degradation products in environmental air samples by liquid chromatography-positive ion electrospray tandem mass spectrometry.

    PubMed

    Raina, Renata; Sun, Lina

    2008-05-01

    This paper describes a new analytical method for determination of organophosphorus pesticides (OPs) along with their degradation products involving liquid chromatography (LC) positive ion electrospray (ESI+) tandem mass spectrometry (MS-MS) with selective reaction monitoring (SRM). Chromatography was performed on a Gemini C6-Phenyl (150 mmx2.0 mm, 3 microm) with a gradient elution using water-methanol with 0.1% formic acid, 2 mM ammonium acetate mobile phase at a flow rate of 0.2 mL min(-1). The LC separation and MS/MS operating conditions were optimized with a total analysis time less than 40 minutes. Method detection limits of 0.1-5 microg L(-1) for selected organophosphorus pesticides (OP), OP oxon degradation products, and other degradation products: 3,5,6-trichloro-2-pyridinol (TCP); 2-isopropyl-6-methyl-4-pyrimidol (IMP); and diethyl phosphate (DEP). Some OPs such as fenchlorphos are less sensitive (MDL 30 microg L(-1)). Calibration curves were linear with coefficients of correlation better than 0.995. A three-point identification approach was adopted with area from first selective reaction monitoring (SRM) transition used for quantitative analysis, while a second SRM transition along with the ratio of areas obtained from the first to second transition are used for confirmation with sample tolerance established by the relative standard deviation of the ratio obtained from standards. This new method permitted the first known detection of OP oxon degradation products including chlorpyrifos oxon at Bratt's Lake, SK and diazinon oxon and malathion oxon at Abbotsford, BC in atmospheric samples. Atmospheric detection limits typically ranged from 0.2-10 pg m(-3).

  16. De novo protein sequencing by combining top-down and bottom-up tandem mass spectra.

    PubMed

    Liu, Xiaowen; Dekker, Lennard J M; Wu, Si; Vanduijn, Martijn M; Luider, Theo M; Tolić, Nikola; Kou, Qiang; Dvorkin, Mikhail; Alexandrova, Sonya; Vyatkina, Kira; Paša-Tolić, Ljiljana; Pevzner, Pavel A

    2014-07-03

    There are two approaches for de novo protein sequencing: Edman degradation and mass spectrometry (MS). Existing MS-based methods characterize a novel protein by assembling tandem mass spectra of overlapping peptides generated from multiple proteolytic digestions of the protein. Because each tandem mass spectrum covers only a short peptide of the target protein, the key to high coverage protein sequencing is to find spectral pairs from overlapping peptides in order to assemble tandem mass spectra to long ones. However, overlapping regions of peptides may be too short to be confidently identified. High-resolution mass spectrometers have become accessible to many laboratories. These mass spectrometers are capable of analyzing molecules of large mass values, boosting the development of top-down MS. Top-down tandem mass spectra cover whole proteins. However, top-down tandem mass spectra, even combined, rarely provide full ion fragmentation coverage of a protein. We propose an algorithm, TBNovo, for de novo protein sequencing by combining top-down and bottom-up MS. In TBNovo, a top-down tandem mass spectrum is utilized as a scaffold, and bottom-up tandem mass spectra are aligned to the scaffold to increase sequence coverage. Experiments on data sets of two proteins showed that TBNovo achieved high sequence coverage and high sequence accuracy.

  17. Method of fabricating bifacial tandem solar cells

    DOEpatents

    Wojtczuk, Steven J; Chiu, Philip T; Zhang, Xuebing; Gagnon, Edward; Timmons, Michael

    2014-10-07

    A method of fabricating on a semiconductor substrate bifacial tandem solar cells with semiconductor subcells having a lower bandgap than the substrate bandgap on one side of the substrate and with subcells having a higher bandgap than the substrate on the other including, first, growing a lower bandgap subcell on one substrate side that uses only the same periodic table group V material in the dislocation-reducing grading layers and bottom subcells as is present in the substrate and after the initial growth is complete and then flipping the substrate and growing the higher bandgap subcells on the opposite substrate side which can be of different group V material.

  18. Highly Effective DNA Extraction Method for Nuclear Short Tandem Repeat Testing of Skeletal Remains from Mass Graves

    PubMed Central

    Davoren, Jon; Vanek, Daniel; Konjhodzić, Rijad; Crews, John; Huffine, Edwin; Parsons, Thomas J.

    2007-01-01

    Aim To quantitatively compare a silica extraction method with a commonly used phenol/chloroform extraction method for DNA analysis of specimens exhumed from mass graves. Methods DNA was extracted from twenty randomly chosen femur samples, using the International Commission on Missing Persons (ICMP) silica method, based on Qiagen Blood Maxi Kit, and compared with the DNA extracted by the standard phenol/chloroform-based method. The efficacy of extraction methods was compared by real time polymerase chain reaction (PCR) to measure DNA quantity and the presence of inhibitors and by amplification with the PowerPlex 16 (PP16) multiplex nuclear short tandem repeat (STR) kit. Results DNA quantification results showed that the silica-based method extracted on average 1.94 ng of DNA per gram of bone (range 0.25-9.58 ng/g), compared with only 0.68 ng/g by the organic method extracted (range 0.0016-4.4880 ng/g). Inhibition tests showed that there were on average significantly lower levels of PCR inhibitors in DNA isolated by the organic method. When amplified with PP16, all samples extracted by silica-based method produced 16 full loci profiles, while only 75% of the DNA extracts obtained by organic technique amplified 16 loci profiles. Conclusions The silica-based extraction method showed better results in nuclear STR typing from degraded bone samples than a commonly used phenol/chloroform method. PMID:17696302

  19. Simultaneous determination and identity confirmation of thiodicarb and its degradation product methomyl in animal-derived foodstuffs using high-performance liquid chromatography with fluorescence detection and tandem mass spectrometry.

    PubMed

    Rahman, Md Musfiqur; Abd El-Aty, A M; Kim, Sung-Woo; Lee, Young-Jun; Na, Tae-Woong; Park, Joon-Seong; Shin, Ho-Chul; Shim, Jae-Han

    2017-01-01

    A high-performance liquid chromatography-fluorescence detection method was developed for the simultaneous determination of thiodicarb and its degradation product methomyl in animal-derived food products, including chicken muscle, beef, pork, table eggs, and milk. Thiodicarb is known to degrade during analysis; therefore, a thorough investigation was carried out, revealing that thiodicarb degrades to methomyl immediately after spiking into a matrix of animal-derived food products. Consequently, thiodicarb was determined as the sum of the parent compound and methomyl. Samples were extracted with acetonitrile and sodium salts, and purified using solid-phase extraction (SPE). The limits of detection (LODs) and quantification (LOQs) were 0.0013 and 0.004mg/kg, respectively, for both analytes in various matrices. Seven-point external calibration curves were obtained, and they showed excellent linearity with determination coefficients (R 2 )≥0.999 for all tested matrices. The method was validated at three fortification levels (LOQ, LOQ×2, and LOQ×10) in triplicate with average recoveries ranging from 84.24 to 112.8% (for methomyl) and relative standard deviations (RSDs)≤6.5% in all matrices. The converted recoveries of thiodicarb in various matrices ranged from 74.80 to 107.80% with RSDs≤4.5%. The identities of both compounds in standard solutions and for recovery were confirmed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The developed method was further validated by accurate reproduction at another laboratory. Finally, the method was applied to market samples collected from different areas (and, in the case of milk, different brands), and none of the samples tested positive for thiodicarb or methomyl. In conclusion, the developed method can be successfully applied for a single-run analysis of thiodicarb and methomyl in livestock products. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Tandem robot control system and method for controlling mobile robots in tandem

    DOEpatents

    Hayward, David R.; Buttz, James H.; Shirey, David L.

    2002-01-01

    A control system for controlling mobile robots provides a way to control mobile robots, connected in tandem with coupling devices, to navigate across difficult terrain or in closed spaces. The mobile robots can be controlled cooperatively as a coupled system in linked mode or controlled individually as separate robots.

  1. Simulation of light-induced degradation of μc-Si in a-Si/μc-Si tandem solar cells by the diode equivalent circuit

    NASA Astrophysics Data System (ADS)

    Weicht, J. A.; Hamelmann, F. U.; Behrens, G.

    2016-02-01

    Silicon-based thin film tandem solar cells consist of one amorphous (a-Si) and one microcrystalline (μc-Si) silicon solar cell. The Staebler - Wronski effect describes the light- induced degradation and temperature-dependent healing of defects of silicon-based solar thin film cells. The solar cell degradation depends strongly on operation temperature. Until now, only the light-induced degradation (LID) of the amorphous layer was examined in a-Si/μc-Si solar cells. The LID is also observed in pc-Si single function solar cells. In our work we show the influence of the light-induced degradation of the μc-Si layer on the diode equivalent circuit. The current-voltage-curves (I-V-curves) for the initial state of a-Si/pc-Si modules are measured. Afterwards the cells are degraded under controlled conditions at constant temperature and constant irradiation. At fixed times the modules are measured at standard test conditions (STC) (AM1.5, 25°C cell temperature, 1000 W/m2) for controlling the status of LID. After the degradation the modules are annealed at dark conditions for several hours at 120°C. After the annealing the dangling bonds in the amorphous layer are healed, while the degradation of the pc-Si is still present, because the healing of defects in pc-Si solar cells needs longer time or higher temperatures. The solar cells are measured again at STC. With this laboratory measured I-V-curves we are able to separate the values of the diode model: series Rs and parallel resistance Rp, saturation current Is and diode factor n.

  2. Determination of nitroaromatic explosives and their degradation products in unsaturated-zone water samples by high-performance liquid chromatography with photodiode-array, mass spectrometric, and tandem mass spectrometric detection

    USGS Publications Warehouse

    Gates, Paul M.; Furlong, E.T.; Dorsey, T.F.; Burkhardt, M.R.

    1996-01-01

    Mass spectrometry and tandem mass spectrometry, coupled by a thermospray interface to a high-performance liguid chromatography system and equipped with a photodiode array detector, were used to determine the presence of nitroaromatic explosives and their degradation products in USA unsaturated-zone water samples. Using this approach, the lower limits of quantitation for explosives determined by mass spectrometry in this study typically ranged from 10 to 100 ng/l.

  3. Method of degrading pollutants in soil

    DOEpatents

    Hazen, Terry C.; Lopez-De-Victoria, Geralyne

    1994-01-01

    A method and system for enhancing the motility of microorganisms by placing an effective amount of chlorinated hydrocarbons, preferably chlorinated alkenes, and most preferably trichloroethylene in spaced relation to the microbes so that the surprisingly strong, monomodal, chemotactic response of the chlorinated hydrocarbon on subsurface microbes can draw the microbes away from or towards and into a substance, as desired. In remediation of groundwater pollution, for example, TCE can be injected into the plume to increase the population of microbes at the plume whereby the plume can be more quickly degraded. A TCE-degrading microbe, such as Welchia alkenophilia, can be used to degrade the TCE following the degradation of the original pollutant.

  4. Methods for degrading lignocellulosic materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vlasenko, Elena; Cherry, Joel; Xu, Feng

    2008-04-08

    The present invention relates to methods for degrading a lignocellulosic material, comprising: treating the lignocellulosic material with an effective amount of one or more cellulolytic enzymes in the presence of at least one surfactant selected from the group consisting of a secondary alcohol ethoxylate, fatty alcohol ethoxylate, nonylphenol ethoxylate, tridecyl ethoxylate, and polyoxyethylene ether, wherein the presence of the surfactant increases the degradation of lignocellulosic material compared to the absence of the surfactant. The present invention also relates to methods for producing an organic substance, comprising: (a) saccharifying a lignocellulosic material with an effective amount of one or more cellulolyticmore » enzymes in the presence of at least one surfactant selected from the group consisting of a secondary alcohol ethoxylate, fatty alcohol ethoxylate, nonylphenol ethoxylate, tridecyl ethoxylate, and polyoxyethylene ether, wherein the presence of the surfactant increases the degradation of lignocellulosic material compared to the absence of the surfactant; (b) fermenting the saccharified lignocellulosic material of step (a) with one or more fermentating microoganisms; and (c) recovering the organic substance from the fermentation.« less

  5. Methods for degrading lignocellulosic materials

    DOEpatents

    Vlasenko, Elena [Davis, CA; Cherry, Joel [Davis, CA; Xu, Feng [Davis, CA

    2008-04-08

    The present invention relates to methods for degrading a lignocellulosic material, comprising: treating the lignocellulosic material with an effective amount of one or more cellulolytic enzymes in the presence of at least one surfactant selected from the group consisting of a secondary alcohol ethoxylate, fatty alcohol ethoxylate, nonylphenol ethoxylate, tridecyl ethoxylate, and polyoxyethylene ether, wherein the presence of the surfactant increases the degradation of lignocellulosic material compared to the absence of the surfactant. The present invention also relates to methods for producing an organic substance, comprising: (a) saccharifying a lignocellulosic material with an effective amount of one or more cellulolytic enzymes in the presence of at least one surfactant selected from the group consisting of a secondary alcohol ethoxylate, fatty alcohol ethoxylate, nonylphenol ethoxylate, tridecyl ethoxylate, and polyoxyethylene ether, wherein the presence of the surfactant increases the degradation of lignocellulosic material compared to the absence of the surfactant; (b) fermenting the saccharified lignocellulosic material of step (a) with one or more fermentating microoganisms; and (c) recovering the organic substance from the fermentation.

  6. Methods for degrading lignocellulosic materials

    DOEpatents

    Vlasenko, Elena [Davis, CA; Cherry, Joel [Davis, CA; Xu, Feng [Davis, CA

    2011-05-17

    The present invention relates to methods for degrading a lignocellulosic material, comprising: treating the lignocellulosic material with an effective amount of one or more cellulolytic enzymes in the presence of at least one surfactant selected from the group consisting of a secondary alcohol ethoxylate, fatty alcohol ethoxylate, nonylphenol ethoxylate, tridecyl ethoxylate, and polyoxyethylene ether, wherein the presence of the surfactant increases the degradation of lignocellulosic material compared to the absence of the surfactant. The present invention also relates to methods for producing an organic substance, comprising: (a) saccharifying a lignocellulosic material with an effective amount of one or more cellulolytic enzymes in the presence of at least one surfactant selected from the group consisting of a secondary alcohol ethoxylate, fatty alcohol ethoxylate, nonylphenol ethoxylate, tridecyl ethoxylate, and polyoxyethylene ether, wherein the presence of the surfactant increases the degradation of lignocellulosic material compared to the absence of the surfactant; (b) fermenting the saccharified lignocellulosic material of step (a) with one or more fermenting microorganisms; and (c) recovering the organic substance from the fermentation.

  7. Method of degrading pollutants in soil

    DOEpatents

    Hazen, T.C.; Lopez-De-Victoria, G.

    1994-07-05

    Disclosed are a method and system for enhancing the motility of microorganisms. This is accomplished by placing an effective amount of chlorinated hydrocarbons, preferably chlorinated alkenes, and most preferably trichloroethylene in spaced relation to the microbes so that the surprisingly strong, monomodal, chemotactic response of the chlorinated hydrocarbon on subsurface microbes can draw the microbes away from or towards and into a substance, as desired. In remediation of groundwater pollution, for example, TCE can be injected into the plume to increase the population of microbes at the plume whereby the plume can be more quickly degraded. A TCE-degrading microbe, such as Welchia alkenophilia, can be used to degrade the TCE following the degradation of the original pollutant. 5 figures.

  8. Investigation of the Persistence of Nerve Agent Degradation ...

    EPA Pesticide Factsheets

    Journal Article The persistence of chemical warfare nerve agent degradation analytes on surfaces is important for reasons ranging from indicating the presence of nerve agent on that surface to environmental restoration of a site after nerve agent release. This study investigates the persistence of several chemical warfare nerve agent degradation analytes on a number of indoor surfaces and presents an approach for wipe sampling of surfaces, followed by wipe extraction and liquid chromatography-tandem mass spectrometry detection. Multiple commercially available wipe materials were investigated to determine optimal wipe recoveries. Tested surfaces, including several porous/permeable and largely nonporous/impermeable surfaces, were investigated to determine recoveries from these indoor surface materials. Wipe extracts were analyzed by ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) and compared with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) results. UPLC provides a sensitive separation of targeted degradation analytes in addition to being nearly four times faster than HPLC, allowing for greater throughput during a widespread release concerning large-scale contamination and subsequent remediation events. Percent recoveries from nonporous/impermeable surfaces were 60-103% for isopropyl methylphosphonate (IMPA), 61-91 % for ethyl methylphosphonate (EMPA), and 60-98% for pinacolyl methylphosphona

  9. Method of radiation degradation of PTFE under vacuum conditions

    NASA Astrophysics Data System (ADS)

    Korenev, Sergey

    2004-09-01

    A new method of radiation degradation of Polytetrafluoroethylene (PTFE) under vacuum conditions is considered in this report. The combination of glow gas discharge and electrical surface discharge (on surface and inside PTFE) increases the efficiency of thermal-radiation degradation. The main mechanism of this degradation method consists of the breaking of C-C and C-F bonds. The vacuum conditions allow decreasing of the concentration of toxic compounds, such as a HF. Experimental results for degradation of PTFE are presented.

  10. TANDEM: matching proteins with tandem mass spectra.

    PubMed

    Craig, Robertson; Beavis, Ronald C

    2004-06-12

    Tandem mass spectra obtained from fragmenting peptide ions contain some peptide sequence specific information, but often there is not enough information to sequence the original peptide completely. Several proprietary software applications have been developed to attempt to match the spectra with a list of protein sequences that may contain the sequence of the peptide. The application TANDEM was written to provide the proteomics research community with a set of components that can be used to test new methods and algorithms for performing this type of sequence-to-data matching. The source code and binaries for this software are available at http://www.proteome.ca/opensource.html, for Windows, Linux and Macintosh OSX. The source code is made available under the Artistic License, from the authors.

  11. A tandem mass spectrometric method for singlet oxygen measurement.

    PubMed

    Karonen, Maarit; Mattila, Heta; Huang, Ping; Mamedov, Fikret; Styring, Stenbjörn; Tyystjärvi, Esa

    2014-01-01

    Singlet oxygen, a harmful reactive oxygen species, can be quantified with the substance 2,2,6,6-tetramethylpiperidine (TEMP) that reacts with singlet oxygen, forming a stable nitroxyl radical (TEMPO). TEMPO has earlier been quantified with electron paramagnetic resonance (EPR) spectroscopy. In this study, we designed an ultra-high-performance liquid chromatographic-tandem mass spectrometric (UHPLC-ESI-MS/MS) quantification method for TEMPO and showed that the method based on multiple reaction monitoring (MRM) can be used for the measurements of singlet oxygen from both nonbiological and biological samples. Results obtained with both UHPLC-ESI-MS/MS and EPR methods suggest that plant thylakoid membranes produce 3.7 × 10(-7) molecules of singlet oxygen per chlorophyll molecule in a second when illuminated with the photosynthetic photon flux density of 2000 μmol m(-2 ) s(-1). © 2014 The American Society of Photobiology.

  12. Numerical investigation & comparison of a tandem-bladed turbocharger centrifugal compressor stage with conventional design

    NASA Astrophysics Data System (ADS)

    Danish, Syed Noman; Qureshi, Shafiq Rehman; EL-Leathy, Abdelrahman; Khan, Salah Ud-Din; Umer, Usama; Ma, Chaochen

    2014-12-01

    Extensive numerical investigations of the performance and flow structure in an unshrouded tandem-bladed centrifugal compressor are presented in comparison to a conventional compressor. Stage characteristics are explored for various tip clearance levels, axial spacings and circumferential clockings. Conventional impeller was modified to tandem-bladed design with no modifications in backsweep angle, meridional gas passage and camber distributions in order to have a true comparison with conventional design. Performance degradation is observed for both the conventional and tandem designs with increase in tip clearance. Linear-equation models for correlating stage characteristics with tip clearance are proposed. Comparing two designs, it is clearly evident that the conventional design shows better performance at moderate flow rates. However; near choke flow, tandem design gives better results primarily because of the increase in throat area. Surge point flow rate also seems to drop for tandem compressor resulting in increased range of operation.

  13. 47 CFR 69.111 - Tandem-switched transport and tandem charge.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 3 2011-10-01 2011-10-01 false Tandem-switched transport and tandem charge. 69... SERVICES (CONTINUED) ACCESS CHARGES Computation of Charges § 69.111 Tandem-switched transport and tandem...-switched transport shall consist of two rate elements, a transmission charge and a tandem switching charge...

  14. Efficient and selective degradation of polyethylenes into liquid fuels and waxes under mild conditions.

    PubMed

    Jia, Xiangqing; Qin, Chuan; Friedberger, Tobias; Guan, Zhibin; Huang, Zheng

    2016-06-01

    Polyethylene (PE) is the largest-volume synthetic polymer, and its chemical inertness makes its degradation by low-energy processes a challenging problem. We report a tandem catalytic cross alkane metathesis method for highly efficient degradation of polyethylenes under mild conditions. With the use of widely available, low-value, short alkanes (for example, petroleum ethers) as cross metathesis partners, different types of polyethylenes with various molecular weights undergo complete conversion into useful liquid fuels and waxes. This method shows excellent selectivity for linear alkane formation, and the degradation product distribution (liquid fuels versus waxes) can be controlled by the catalyst structure and reaction time. In addition, the catalysts are compatible with various polyolefin additives; therefore, common plastic wastes, such as postconsumer polyethylene bottles, bags, and films could be converted into valuable chemical feedstocks without any pretreatment.

  15. Methods of degrading napalm B

    DOEpatents

    Tyndall, R.L.; Vass, A.

    1995-09-12

    Methods of degrading napalm and/or trinitrotoluene involve contacting the waste with specific intra-amoebic isolates of ATCC 40908 and/or dispersants derived therefrom. Useful isolates are deposited as ATCC 77529, NAP-1 deposited as ATCC 77526 and 13 deposited as ATCC 77527.

  16. Evaluation of a Commercial Sandwich Enzyme-Linked Immunosorbent Assay for the Quantification of Beta-Casomorphin 7 in Yogurt Using Solid-Phase Extraction Coupled to Liquid Chromatography-Tandem Mass Spectrometry as the "Gold Standard" Method.

    PubMed

    Nguyen, Duc Doan; Busetti, Francesco; Johnson, Stuart Keith; Solah, Vicky Ann

    2018-03-01

    This study investigated beta-casomorphin 7 (BCM7) in yogurt by means of LC-tandem MS (MS/MS) and enzyme-linked immunosorbent assay (ELISA) and use LC-MS/MS as the "gold standard" method to evaluate the applicability of a commercial ELISA. The level of BCM7 in milk obtained from ELISA analysis was much lower than that obtained by LC-MS/MS analysis and trended to increase during fermentation and storage of yogurt. Meanwhile, the results obtained from LC-MS/MS showed that BCM7 degraded during stages of yogurt processing, and its degradation may have been caused by X-prolyl dipeptidyl aminopeptidase activity. As a result, the commercial sandwich ELISA kit was not suitable for the quantification of BCM7 in fermented dairy milk.

  17. Analytical method validation to evaluate dithiocarbamates degradation in biobeds in South of Brazil.

    PubMed

    Vareli, Catiucia S; Pizzutti, Ionara R; Gebler, Luciano; Cardoso, Carmem D; Gai, Daniela S H; Fontana, Marlos E Z

    2018-07-01

    In order to evaluate the efficiency of biobeds on DTC degradation, the aim of this study was to apply, optimize and validate a method to determine dithiocarbamate (mancozeb) in biobeds using gas chromatography-tandem mass spectrometry (GC-MS). The DTC pesticide mancozeb was hydrolysed in a tin (II) chloride solution at 1.5% in HCl (4 mol L -1 ), during 1 h in a water bath at 80 °C, and the CS 2 formed was extracted in isooctane. After cooling, 1 mL of the organic layer was transferred to an auto sampler vial and analyzed by GC-MS. A complete validation study was performed and the following parameters were assessed: linearity of the analytical curve (r 2 ), estimated method and instrument limits of detection and limits of quantification (LODm, LODi, LOQm and LOQi, respectively), accuracy (recovery%), precision (RSD%) and matrix effects. Recovery experiments were carried out with a standard spiking solution of the DTC pesticide thiram. Blank biobed (biomixture) samples were spiked at the three levels corresponding to the CS 2 concentrations of 1, 3 and 5 mg kg -1 , with seven replicates each (n = 7). The method presented satisfactory accuracy, with recoveries within the range of 89-96% and RSD ≤ 11%. The analytical curves were linear in the concentration range of 0.05-10 µg CS 2 mL -1 (r 2 > 0.9946). LODm and LOQm were 0.1 and 0.5 mg CS 2 kg -1 , respectively, and the calculated matrix effects were not significant (≤ 20%). The validated method was applied to 80 samples (biomixture), from sixteen different biobeds (collected at five sampling times) during fourteen months. Ten percent of samples presented CS 2 concentration below the LOD (0.1 mg CS 2 kg -1 ) and 49% of them showed results below the LOQ (0.5 mg CS 2 kg -1 ), which demonstrates the biobeds capability to degrade DTC. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Methods of degrading napalm B

    DOEpatents

    Tyndall, Richard L.; Vass, Arpad

    1995-01-01

    Methods of degrading napalm and/or trinitrotoluene involve contacting the waste with specific intra-amoebic isolates of ATCC 40908 and/or dispersants derived therefrom. Useful isolates include is deposited as ATCC 77529, NAP-1 deposited as ATCC 77526 and 13 deposited as ATCC 77527.

  19. Ultra-high-pressure liquid chromatography-tandem mass spectrometry method for the determination of alkylphenols in soil.

    PubMed

    Wang, Jing; Pan, Hefang; Liu, Zhengzheng; Ge, Fei

    2009-03-20

    A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 microm, 50 mm x 2.1mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0-103.4%, with the RSD<15%. The calibration curves for alkylphenols were linear within the range of 0.01-0.4 microg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 microg/kg.

  20. Ultra-high-performance liquid chromatography/tandem high-resolution mass spectrometry analysis of sixteen red beverages containing carminic acid: identification of degradation products by using principal component analysis/discriminant analysis.

    PubMed

    Gosetti, Fabio; Chiuminatto, Ugo; Mazzucco, Eleonora; Mastroianni, Rita; Marengo, Emilio

    2015-01-15

    The study investigates the sunlight photodegradation process of carminic acid, a natural red colourant used in beverages. For this purpose, both carminic acid aqueous standard solutions and sixteen different commercial beverages, ten containing carminic acid and six containing E120 dye, were subjected to photoirradiation. The results show different patterns of degradation, not only between the standard solutions and the beverages, but also from beverage to beverage. Due to the different beverage recipes, unpredictable reactions take place between the dye and the other ingredients. To identify the dye degradation products in a very complex scenario, a methodology was used, based on the combined use of principal component analysis with discriminant analysis and ultra-high-performance liquid chromatography coupled with tandem high resolution mass spectrometry. The methodology is unaffected by beverage composition and allows the degradation products of carminic acid dye to be identified for each beverage. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Flight and Analytical Methods for Determining the Coupled Vibration Response of Tandem Helicopters

    NASA Technical Reports Server (NTRS)

    Yeates, John E , Jr; Brooks, George W; Houbolt, John C

    1957-01-01

    Chapter one presents a discussion of flight-test and analysis methods for some selected helicopter vibration studies. The use of a mechanical shaker in flight to determine the structural response is reported. A method for the analytical determination of the natural coupled frequencies and mode shapes of vibrations in the vertical plane of tandem helicopters is presented in Chapter two. The coupled mode shapes and frequencies are then used to calculate the response of the helicopter to applied oscillating forces.

  2. The application of chiral ultra-high-performance liquid chromatography tandem mass spectrometry to the separation of the zoxamide enantiomers and the study of enantioselective degradation process in agricultural plants.

    PubMed

    Pan, Xinglu; Dong, Fengshou; Chen, Zenglong; Xu, Jun; Liu, Xingang; Wu, Xiaohu; Zheng, Yongquan

    2017-11-24

    In this study, an effective and sensitive chiral analytical method was developed to detect zoxamide enantiomers in vegetables, fruits and environmental matrices using ultra-high-performance liquid chromatography-tandem mass spectrometry. Optimal separation conditions were achieved with Lux Amylose-2 chiral column using acetonitrile/water (70:30v/v) as mobile phase with a flow rate and column temperature of 0.5mL/min and 25°C. The absolute configuration, optical rotation and elution order were confirmed for the first time. The average recoveries in all matrices at four spiking levels (0.5, 5, 50, 250μg/kg) ranged from 89.7 to 117.4%, with relative standard deviations being less than 10.9% for two enantiomers. The enantioselective dissipation of zoxamide in tomato showed that (-)-R-zoxamide was preferentially degraded leading to an enrichment of (+)-S-isomer, with half-lives of 3.80 d and 5.17 d, respectively. Inversely, (+)-S-zoxamide degraded faster than (-)-R-zoxamide in pepper (1.95day and 2.28day, respectively) and grape (2.03day and 2.87day). No significant enantioselectivity was observed in cucumber. The results of this study could help facilitate more accurate risk assessments of zoxamide in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Efficient and selective degradation of polyethylenes into liquid fuels and waxes under mild conditions

    PubMed Central

    Jia, Xiangqing; Qin, Chuan; Friedberger, Tobias; Guan, Zhibin; Huang, Zheng

    2016-01-01

    Polyethylene (PE) is the largest-volume synthetic polymer, and its chemical inertness makes its degradation by low-energy processes a challenging problem. We report a tandem catalytic cross alkane metathesis method for highly efficient degradation of polyethylenes under mild conditions. With the use of widely available, low-value, short alkanes (for example, petroleum ethers) as cross metathesis partners, different types of polyethylenes with various molecular weights undergo complete conversion into useful liquid fuels and waxes. This method shows excellent selectivity for linear alkane formation, and the degradation product distribution (liquid fuels versus waxes) can be controlled by the catalyst structure and reaction time. In addition, the catalysts are compatible with various polyolefin additives; therefore, common plastic wastes, such as postconsumer polyethylene bottles, bags, and films could be converted into valuable chemical feedstocks without any pretreatment. PMID:27386559

  4. Identification of the Phenol Functionality in Deprotonated Monomeric and Dimeric Lignin Degradation Products via Tandem Mass Spectrometry Based on Ion-Molecule Reactions with Diethylmethoxyborane

    NASA Astrophysics Data System (ADS)

    Zhu, Hanyu; Max, Joann P.; Marcum, Christopher L.; Luo, Hao; Abu-Omar, Mahdi M.; Kenttämaa, Hilkka I.

    2016-11-01

    Conversion of lignin into smaller molecules provides a promising alternate and sustainable source for the valuable chemicals currently derived from crude oil. Better understanding of the chemical composition of the resulting product mixtures is essential for the optimization of such conversion processes. However, these mixtures are complex and contain isomeric molecules with a wide variety of functionalities, which makes their characterization challenging. Tandem mass spectrometry based on ion-molecule reactions has proven to be a powerful tool in functional group identification and isomer differentiation for previously unknown compounds. This study demonstrates that the identification of the phenol functionality, the most commonly observed functionality in lignin degradation products, can be achieved via ion-molecule reactions between diethylmethoxyborane (DEMB) and the deprotonated analyte in the absence of strongly electron-withdrawing substituents in the ortho- and para-positions. Either a stable DEMB adduct or an adduct that has lost a methanol molecule (DEMB adduct-MeOH) is formed for these ions. Deprotonated phenols with an adjacent phenol or hydroxymethyl functionality or a conjugated carboxylic acid functionality can be identified based on the formation of DEMB adduct-MeOH. Deprotonated compounds not containing the phenol functionality and phenols containing an electron-withdrawing ortho- or para-substituent were found to be unreactive toward diethylmethoxyborane. Hence, certain deprotonated isomeric compounds with phenol and carboxylic acid, aldehyde, carboxylic acid ester, or nitro functionalities can be differentiated via these reactions. The above mass spectrometry method was successfully coupled with high-performance liquid chromatography for the analysis of a complex biomass degradation mixture.

  5. DEVELOPMENT OF METHOD 535 FOR THE DETERMINATION OF CHLOROACETANILIDE AND OTHER ACETAMIDE HERBICIDE DEGRADATES IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY

    EPA Science Inventory

    EPA Method 535 has been developed in order to provide a method for the analysis of "Alachlor ESA and other acetanilide degradation products" which are listed on U.S. EPA's 1998 Drinking Water Contaminant Candidate List. Method 535 uses solid phase extraction with a nonporous gr...

  6. A LDR-PCR approach for multiplex polymorphisms genotyping of severely degraded DNA with fragment sizes <100 bp.

    PubMed

    Zhang, Zhen; Wang, Bao-Jie; Guan, Hong-Yu; Pang, Hao; Xuan, Jin-Feng

    2009-11-01

    Reducing amplicon sizes has become a major strategy for analyzing degraded DNA typical of forensic samples. However, amplicon sizes in current mini-short tandem repeat-polymerase chain reaction (PCR) and mini-sequencing assays are still not suitable for analysis of severely degraded DNA. In this study, we present a multiplex typing method that couples ligase detection reaction with PCR that can be used to identify single nucleotide polymorphisms and small-scale insertion/deletions in a sample of severely fragmented DNA. This method adopts thermostable ligation for allele discrimination and subsequent PCR for signal enhancement. In this study, four polymorphic loci were used to assess the ability of this technique to discriminate alleles in an artificially degraded sample of DNA with fragment sizes <100 bp. Our results showed clear allelic discrimination of single or multiple loci, suggesting that this method might aid in the analysis of extremely degraded samples in which allelic drop out of larger fragments is observed.

  7. Biological Matrix Effects in Quantitative Tandem Mass Spectrometry-Based Analytical Methods: Advancing Biomonitoring

    PubMed Central

    Panuwet, Parinya; Hunter, Ronald E.; D’Souza, Priya E.; Chen, Xianyu; Radford, Samantha A.; Cohen, Jordan R.; Marder, M. Elizabeth; Kartavenka, Kostya; Ryan, P. Barry; Barr, Dana Boyd

    2015-01-01

    The ability to quantify levels of target analytes in biological samples accurately and precisely, in biomonitoring, involves the use of highly sensitive and selective instrumentation such as tandem mass spectrometers and a thorough understanding of highly variable matrix effects. Typically, matrix effects are caused by co-eluting matrix components that alter the ionization of target analytes as well as the chromatographic response of target analytes, leading to reduced or increased sensitivity of the analysis. Thus, before the desired accuracy and precision standards of laboratory data are achieved, these effects must be characterized and controlled. Here we present our review and observations of matrix effects encountered during the validation and implementation of tandem mass spectrometry-based analytical methods. We also provide systematic, comprehensive laboratory strategies needed to control challenges posed by matrix effects in order to ensure delivery of the most accurate data for biomonitoring studies assessing exposure to environmental toxicants. PMID:25562585

  8. Impeller tandem blade study with grid embedding for local grid refinement

    NASA Technical Reports Server (NTRS)

    Bache, George

    1992-01-01

    Flow non-uniformity at the discharge of high power density impellers can result in significant unsteady interactions between impeller blades and downstream diffuser vanes. These interactions result in degradation of both performance and pump reliability. The MSFC Pump Technology Team has recognized the importance of resolving this problem and has thus initiated the development and testing of a high head coefficient impeller. One of the primary goals of this program is to improve impeller performance and discharge flow uniformity. The objective of the present work is complimentary. Flow uniformity and performance gains were sought through the application of a tandem blade arrangement. The approach adopted was to numerically establish flow characteristics at the impeller discharge for the baseline MSFC impeller and then parametrically evaluate tandem blade configurations. A tandem design was sought that improves both impeller performance and discharge uniformity. The Navier-Stokes solver AEROVISC was used to conduct the study. Grid embedding is used to resolve local gradients while attempting to minimize model size. Initial results indicate that significant gains in flow uniformity can be achieved through the tandem blade concept and that blade clocking rather than slot location is the primary driver for flow uniformity.

  9. MR-Tandem: parallel X!Tandem using Hadoop MapReduce on Amazon Web Services.

    PubMed

    Pratt, Brian; Howbert, J Jeffry; Tasman, Natalie I; Nilsson, Erik J

    2012-01-01

    MR-Tandem adapts the popular X!Tandem peptide search engine to work with Hadoop MapReduce for reliable parallel execution of large searches. MR-Tandem runs on any Hadoop cluster but offers special support for Amazon Web Services for creating inexpensive on-demand Hadoop clusters, enabling search volumes that might not otherwise be feasible with the compute resources a researcher has at hand. MR-Tandem is designed to drop in wherever X!Tandem is already in use and requires no modification to existing X!Tandem parameter files, and only minimal modification to X!Tandem-based workflows. MR-Tandem is implemented as a lightly modified X!Tandem C++ executable and a Python script that drives Hadoop clusters including Amazon Web Services (AWS) Elastic Map Reduce (EMR), using the modified X!Tandem program as a Hadoop Streaming mapper and reducer. The modified X!Tandem C++ source code is Artistic licensed, supports pluggable scoring, and is available as part of the Sashimi project at http://sashimi.svn.sourceforge.net/viewvc/sashimi/trunk/trans_proteomic_pipeline/extern/xtandem/. The MR-Tandem Python script is Apache licensed and available as part of the Insilicos Cloud Army project at http://ica.svn.sourceforge.net/viewvc/ica/trunk/mr-tandem/. Full documentation and a windows installer that configures MR-Tandem, Python and all necessary packages are available at this same URL. brian.pratt@insilicos.com

  10. Method for the Simultaneous Quantitation of Apolipoprotein E Isoforms using Tandem Mass Spectrometry

    PubMed Central

    Wildsmith, Kristin R.; Han, Bomie; Bateman, Randall J.

    2009-01-01

    Using Apolipoprotein E (ApoE) as a model protein, we developed a protein isoform analysis method utilizing Stable Isotope Labeling Tandem Mass Spectrometry (SILT MS). ApoE isoforms are quantitated using the intensities of the b and y ions of the 13C-labeled tryptic isoform-specific peptides versus unlabeled tryptic isoform-specific peptides. The ApoE protein isoform analysis using SILT allows for the simultaneous detection and relative quantitation of different ApoE isoforms from the same sample. This method provides a less biased assessment of ApoE isoforms compared to antibody-dependent methods, and may lead to a better understanding of the biological differences between isoforms. PMID:19653990

  11. MR-Tandem: parallel X!Tandem using Hadoop MapReduce on Amazon Web Services

    PubMed Central

    Pratt, Brian; Howbert, J. Jeffry; Tasman, Natalie I.; Nilsson, Erik J.

    2012-01-01

    Summary: MR-Tandem adapts the popular X!Tandem peptide search engine to work with Hadoop MapReduce for reliable parallel execution of large searches. MR-Tandem runs on any Hadoop cluster but offers special support for Amazon Web Services for creating inexpensive on-demand Hadoop clusters, enabling search volumes that might not otherwise be feasible with the compute resources a researcher has at hand. MR-Tandem is designed to drop in wherever X!Tandem is already in use and requires no modification to existing X!Tandem parameter files, and only minimal modification to X!Tandem-based workflows. Availability and implementation: MR-Tandem is implemented as a lightly modified X!Tandem C++ executable and a Python script that drives Hadoop clusters including Amazon Web Services (AWS) Elastic Map Reduce (EMR), using the modified X!Tandem program as a Hadoop Streaming mapper and reducer. The modified X!Tandem C++ source code is Artistic licensed, supports pluggable scoring, and is available as part of the Sashimi project at http://sashimi.svn.sourceforge.net/viewvc/sashimi/trunk/trans_proteomic_pipeline/extern/xtandem/. The MR-Tandem Python script is Apache licensed and available as part of the Insilicos Cloud Army project at http://ica.svn.sourceforge.net/viewvc/ica/trunk/mr-tandem/. Full documentation and a windows installer that configures MR-Tandem, Python and all necessary packages are available at this same URL. Contact: brian.pratt@insilicos.com PMID:22072385

  12. Phytoremediation-biorefinery tandem for effective clean-up of metal contaminated soil and biomass valorisation.

    PubMed

    Sotenko, Maria; Coles, Stuart; Barker, Guy; Song, Lijiang; Jiang, Ying; Longhurst, Philip; Romanova, Tamara; Shuvaeva, Olga; Kirwan, Kerry

    2017-11-02

    During the last few decades, phytoremediation process has attracted much attention because of the growing concerns about the deteriorating quality of soil caused by anthropogenic activities. Here, a tandem phytoremediation/biorefinery process was proposed as a way to turn phytoremediation into a viable commercial method by producing valuable chemicals in addition to cleaned soil. Two agricultural plants (Sinapis alba and Helianthus annuus) were grown in moderately contaminated soil with ca. 100 ppm of Ni and further degraded by a fungal lignin degrader-Phanerochaete chrysosporium. Several parameters have been studied, including the viability of plants, biomass yield, and their accumulating and remediating potentials. Further, downstream processing showed that up to 80% of Ni can be easily extracted from contaminated biomass by aqueous extraction at mild conditions. Finally, it was demonstrated that the growth of plants on the contaminated soil could be degraded by P. chrysosporium, and the effect of nickel and biomass pretreatment on the solid-state fermentation was studied. The proposed and studied methodology in this work could pave the way for successful commercialization of the phytoremediation process in the near future.

  13. [Measurement of free urinary cortisol and cortisone using liquid chromatography associated with tandem mass spectrometry method].

    PubMed

    Vieira, José Gilberto H; Nakamura, Odete H; Carvalho, Valdemir M

    2005-04-01

    Free urinary cortisol (UFF) measurement is one of the most useful screening tests for Cushing's syndrome. Immunoassays employed today by most clinical laboratories present limitations, specially concerning specificity. These limitations restrain a widespread application of the method, as well as the comparison of results obtained by the use of different methods. We present the development and characterization of a UFF and cortisone method based on liquid chromatography and tandem mass spectrometry (LC-MS/MS). A 200 microL aliquot from a 24 h urine sample is mixed with a solution containing a known quantity of deuterated cortisol and on-line extracted in solid phase (C18). The eluate is transferred to a second C18 column (Phenomenex Luna, 3 micro, 50 x 2 mm) and the isocratic mode elution profile is directly applied to a tandem mass spectrometer model Quattro Micro operating in positive mode atmospheric pressure chemical ionization (APCI). All process is automated and the quantification is performed by isotopic dilution, based on the analyte and the deuterated internal standard peak area ratios. The specificity study showed that all the steroids tested presented cross reactivity of <1% for cortisol and cortisone. Functional sensitivity is <1 microg/L for both steroids, and the interassay CV <8%. Recovery and linearity studies were satisfactory and comparison of results obtained using a RIA for UFF and the present method in 98 routine samples showed a correlation of r= 0.838, with the results obtained with LC-MS/MS significantly lower (medians of 22.0 vs. 49.4 microg/24 h for RIA) (P<0.0001). Reference values for cortisol were defined as values between 11 and 43 microg/24 h, compatible to those recently described for similar methods. The concomitant measurement of UF cortisone allows the study of the activity of the enzyme 11beta-HSD2 and the diagnosis of the apparent mineralocorticoid excess syndrome. The method represents the first steroid assay of a new generation

  14. Evaluation of Offline Tandem and Online Solid-Phase Extraction with Liquid Chromatography/Electrospray Ionization-Mass Spectrometry for Analysis of Antibiotics in Ambient Water and Comparison to an Independent Method

    USGS Publications Warehouse

    Meyer, M.T.; Lee, E.A.; Ferrell, G.M.; Bumgarner, J.E.; Varns, Jerry

    2007-01-01

    This report describes the performance of an offline tandem solid-phase extraction (SPE) method and an online SPE method that use liquid chromatography/mass spectrometry for the analysis of 23 and 35 antibiotics, respectively, as used in several water-quality surveys conducted since 1999. In the offline tandem SPE method, normalized concentrations for the quinolone, macrolide, and sulfonamide antibiotics in spiked environmental samples averaged from 81 to 139 percent of the expected spiked concentrations. A modified standard-addition technique was developed to improve the quantitation of the tetracycline antibiotics, which had 'apparent' concentrations that ranged from 185 to 1,200 percent of their expected spiked concentrations in matrix-spiked samples. In the online SPE method, normalized concentrations for the quinolone, macrolide, sulfonamide, and tetracycline antibiotics in matrix-spiked samples averaged from 51 to 142 percent of their expected spiked concentrations, and the beta-lactam antibiotics in matrix-spiked samples averaged from 22 to 76 percent of their expected spiked concentration. Comparison of 44 samples analyzed by both the offline tandem SPE and online SPE methods showed 50 to 100 percent agreement in sample detection for overlapping analytes and 68 to 100 percent agreement in a presence-absence comparison for all analytes. The offline tandem and online SPE methods were compared to an independent method that contains two overlapping antibiotic compounds, sulfamethoxazole and trimethoprim, for 96 and 44 environmental samples, respectively. The offline tandem SPE showed 86 and 92 percent agreement in sample detection and 96 and 98 percent agreement in a presence-absence comparison for sulfamethoxazole and trimethoprim, respectively. The online SPE method showed 57 and 56 percent agreement in sample detection and 72 and 91 percent agreement in presence-absence comparison for sulfamethoxazole and trimethoprim, respectively. A linear regression with

  15. A novel tandem mass spectrometry method for first-line screening of mainly beta-thalassemia from dried blood spots.

    PubMed

    Yu, Chaowen; Huang, Shuodan; Wang, Ming; Zhang, Juan; Liu, Hao; Yuan, Zhaojian; Wang, Xingbin; He, Xiaoyan; Wang, Jie; Zou, Lin

    2017-02-10

    Traditional methods for thalassemia screening are time-consuming and easily affected by cell hemolysis or hemoglobin degradation in stored blood samples. Tandem mass spectrometry (MS/MS) proved to be an effective technology for sickle cell disorders (SCD) screening. Here, we developed a novel MS/MS method for β-thalassemia screening from dried blood spots (DBS). Stable isotopic-labeled peptides were used as internal standards for quantification and calculation of the α:β-globin ratios. We used the α:β-globin ratio cutoffs to differentiate between normal individuals and patients with thalassemia. About 781 patients and 300 normal individuals were analyzed. The α:β-globin ratios showed significant difference between normal and β-thalassemia patients (P<0.01), particularly when the disease was homozygous or double heterozygous with another α- or β-thalassemia mutation. In the parallel study, all cases screened for suspected thalassemia from six hundred DBS samples by using this MS/MS method were successfully confirmed by genotyping. The intra-assay and inter-assay CVs of the ratios ranged from 2.4% to 3.9% and 4.7% to 7.1%, and there was no significant sample carryover or matrix effect for this MS/MS method. Combined with SCD screening, this MS/MS method could be used as a first-line screening assay for both structural and expression abnormalities of human hemoglobin. Traditional methods for thalassemia screening were depending on the structural integrity of tetramers and could be affected by hemolysis and degradation of whole blood samples, especially when stored. We used proteospecific peptides produced by the tryptic digestion of each globin to evaluate the production ratio between α- and β-globin chains, which turned out to be quite stable even when stored for more than two months. Though most of the peptides were specific to α-globin or β-globin, we only chose four most informative peptides and its stable isotopic-labeled peptides as internal

  16. Ultra-performance liquid chromatography-tandem mass spectrometry for the determination of atypical antipsychotics and some metabolites in in vitro samples.

    PubMed

    Li, Kun-Yan; Zhou, Yan-Gang; Ren, Hua-Yi; Wang, Feng; Zhang, Bi-Kui; Li, Huan-De

    2007-05-01

    The ultra-performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-ESI-MS/MS) method has been developed to perform the determination of quetiapine, perospirone, aripiprazole and quetiapine sulfoxide in in vitro samples in less than 3 min. The UPLC separation was carried out using an Acquity UPLC BEH C18 column (100 mm x 2.1mm i.d., 1.7 microm particle size) that provided high efficiency and resolution in combination with high linear velocities. The UPLC system was coupled to a Waters Micromass Quattro Premier XE tandem quadrupole mass spectrometer. This system permits high-speed data acquisition without peak intensity degradation, and produces sharp and narrow chromatographic peaks (w(h) about 2.5s) of compounds. The determination was performed in multiple reaction monitoring (MRM) mode. The quantification parameters of the developed method were established, obtaining instrumental LODs lower than 0.005 microg/l and a repeatability at a low concentration level lower than 10% CV (n=10). Finally, the method was successfully applied to the analysis of atypical antipsychotics and some metabolites in in vitro samples.

  17. Ultra high performance liquid chromatography with tandem mass spectrometry screening and mutagenicity evaluation of photodegradation products of Carmoisine (E122) dye in a beverage.

    PubMed

    Yamjala, Karthik; Nainar, Meyyanathan Subramania; Ramisetti, Nageswara Rao

    2016-06-01

    The present study deals with the separation and identification of the photodegradation products formed when a commercial soft drink containing Carmoisine (E122) dye was exposed to natural sunlight. An ultra high performance liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed and validated to identify the unknown species of E122. During the study, it was observed that the dye decolourizes rapidly in beverage when compared to model standard solutions. The sunlight irradiation of beverage containing E122 resulted in four photodegradation products as identified by nontarget screening using high-resolution tandem mass spectrometry. Accurate mass measurements were used to identify the elemental composition, and to elucidate the structures of degradation products a software tool was employed. The degradation products (P1-P4) were formed from the interactions of the dye with other ingredients present in the beverage. The toxicity of the degradation products was evaluated on five bacterial strains (TA98, TA100, TA1535, TA1537, and WP2 uvrA pKM101) through an in vitro bacterial reverse mutation assay. The photodegradation products showed strong mutagenic potential in strain TA 100 (without S9) as detected by the Ames assay. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. MiniX-STR multiplex system population study in Japan and application to degraded DNA analysis.

    PubMed

    Asamura, H; Sakai, H; Kobayashi, K; Ota, M; Fukushima, H

    2006-05-01

    We sought to evaluate a more effective system for analyzing X-chromosomal short tandem repeats (X-STRs) in highly degraded DNA. To generate smaller amplicon lengths, we designed new polymerase chain reaction (PCR) primers for DXS7423, DXS6789, DXS101, GATA31E08, DXS8378, DXS7133, DXS7424, and GATA165B12 at X-linked short tandem repeat (STR) loci, devising two miniX-multiplex PCR systems. Among 333 Japanese individuals, these X-linked loci were detected in amplification products ranging in length from 76 to 169 bp, and statistical analyses of the eight loci indicated a high usefulness for the Japanese forensic practice. Results of tests on highly degraded DNA indicated the miniX-STR multiplex strategies to be an effective system for analyzing degraded DNA. We conclude that analysis by the current miniX-STR multiplex systems offers high effectiveness for personal identification from degraded DNA samples.

  19. Liquid Chromatography with Post-Column Reagent Addition of Ammonia in Methanol Coupled to Negative Ion Electrospray Ionization Tandem Mass Spectrometry for Determination of Phenoxyacid Herbicides and their Degradation Products in Surface Water

    PubMed Central

    Raina, Renata; Etter, Michele L.

    2010-01-01

    A new liquid chromatography (LC)-negative ion electrospray ionization (ESI−)–tandem mass spectrometry (MS/MS) method with post-column addition of ammonia in methanol has been developed for the analysis of acid herbicides: 2,4-dichlorophenoxy acetic acid, 4-chloro-o-tolyloxyacetic acid, 2-(2-methyl-4-chlorophenoxy)butyric acid, mecoprop, dichlorprop, 4-(2,4-dichlorophenoxy) butyric acid, 2,4,5-trichlorophenoxy propionic acid, dicamba and bromoxynil, along with their degradation products: 4-chloro-2-methylphenol, 2,4-dichlorophenol, 2,4,5-trichlorophenol and 3,5-dibromo-4-hydroxybenzoic acid. The samples were extracted from the surface water matrix using solid-phase extraction (SPE) with a polymeric sorbent and analyzed with LC ESI− with selected reaction monitoring (SRM) using a three-point confirmation approach. Chromatography was performed on a Zorbax Eclipse XDB-C18 (50 × 4.6 mm i.d., 1.8 μm) with a gradient elution using water-methanol with 2 mM ammonium acetate mobile phase at a flow rate of 0.15 mL/min. Ammonia in methanol (0.8 M) was added post-column at a flow rate of 0.05 mL/min to enhance ionization of the degradation products in the MS source. One SRM transition was used for quantitative analysis while the second SRM along with the ratio of SRM1/SRM2 within the relative standard deviation determined by standards for each individual pesticide and retention time match were used for confirmation. The standard deviation of ratio of SRM1/SRM2 obtained from standards run on the day of analysis for different phenoxyacid herbicides ranged from 3.9 to 18.5%. Limits of detection (LOD) were between 1 and 15 ng L−1 and method detection limits (MDL) with strict criteria requiring <25% deviation of peak area from best-fit line for both SRM1 and SRM2 ranged from 5 to 10 ng L−1 for acid ingredients (except dicamba at 30 ng L−1) and from 2 to 30 ng L−1 for degradation products. The SPE-LC-ESI− MS/MS method permitted low nanogram-per-liter determination

  20. Sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous determination of paracetamol and guaifenesin in human plasma.

    PubMed

    Chen, Xiaoyan; Huang, Jia; Kong, Zhang; Zhong, Dafang

    2005-03-25

    A rapid and sensitive method for the simultaneous determination of paracetamol and guaifenesin in human plasma was developed and validated, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. After extracted from plasma samples by diethyl ether-dichloromethane (3:2, v/v), the analytes and internal standard osalmide were chromatographed on a C18 column. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method was linear in the concentration range of 0.05-20.0 microg/ml for paracetamol and 5.0-2000.0 ng/ml for guaifenesin. The intra- and inter-day precision was within 14% for both paracetamol and guaifenesin. The assay accuracy was within +/-2.4% for the analytes. This is the first assay method described for the simultaneous determination of paracetamol and guaifenesin in plasma using one chromatographic run. The method was successfully employed in a pharmacokinetic study after an oral administration of a multicomponent formulation, containing 650 mg paracetamol, 200 mg guaifenesin, 60 mg pseudoephedrine and 20 mg dextrorphan.

  1. A review of recent progress in heterogeneous silicon tandem solar cells

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Masafumi; Lee, Kan-Hua; Araki, Kenji; Kojima, Nobuaki

    2018-04-01

    Silicon solar cells are the most established solar cell technology and are expected to dominate the market in the near future. As state-of-the-art silicon solar cells are approaching the Shockley-Queisser limit, stacking silicon solar cells with other photovoltaic materials to form multi-junction devices is an obvious pathway to further raise the efficiency. However, many challenges stand in the way of fully realizing the potential of silicon tandem solar cells because heterogeneously integrating silicon with other materials often degrades their qualities. Recently, above or near 30% silicon tandem solar cell has been demonstrated, showing the promise of achieving high-efficiency and low-cost solar cells via silicon tandem. This paper reviews the recent progress of integrating solar cell with other mainstream solar cell materials. The first part of this review focuses on the integration of silicon with III-V semiconductor solar cells, which is a long-researched topic since the emergence of III-V semiconductors. We will describe the main approaches—heteroepitaxy, wafer bonding and mechanical stacking—as well as other novel approaches. The second part introduces the integration of silicon with polycrystalline thin-film solar cells, mainly perovskites on silicon solar cells because of its rapid progress recently. We will also use an analytical model to compare the material qualities of different types of silicon tandem solar cells and project their practical efficiency limits.

  2. Methods And Systms For Analyzing The Degradation And Failure Of Mechanical Systems

    DOEpatents

    Jarrell, Donald B.; Sisk, Daniel R.; Hatley, Darrel D.; Kirihara, Leslie J.; Peters, Timothy J.

    2005-02-08

    Methods and systems for identifying, understanding, and predicting the degradation and failure of mechanical systems are disclosed. The methods include measuring and quantifying stressors that are responsible for the activation of degradation mechanisms in the machine component of interest. The intensity of the stressor may be correlated with the rate of physical degradation according to some determinable function such that a derivative relationship exists between the machine performance, degradation, and the underlying stressor. The derivative relationship may be used to make diagnostic and prognostic calculations concerning the performance and projected life of the machine. These calculations may be performed in real time to allow the machine operator to quickly adjust the operational parameters of the machinery in order to help minimize or eliminate the effects of the degradation mechanism, thereby prolonging the life of the machine. Various systems implementing the methods are also disclosed.

  3. A novel mechanochemical method for reconstructing the moisture-degraded HKUST-1.

    PubMed

    Sun, Xuejiao; Li, Hao; Li, Yujie; Xu, Feng; Xiao, Jing; Xia, Qibin; Li, Yingwei; Li, Zhong

    2015-07-11

    A novel mechanochemical method was proposed to reconstruct quickly moisture-degraded HKUST-1. The degraded HKUST-1 can be restored within minutes. The reconstructed samples were characterized, and confirmed to have 95% surface area and 92% benzene capacity of the fresh HKUST-1. It is a simple and effective strategy for degraded MOF reconstruction.

  4. Testing Method of Degrading Heavy Oil Pollution by Microorganisms

    NASA Astrophysics Data System (ADS)

    Wu, Qi; Zhao, Lin; Ma, Aijin

    2018-01-01

    With the development of human society, we are more and more relying on the petrochemical energy. The use of petrochemical energy not only brings us great convenience, but is also accompanied by a series of environmental pollution problems, especially oil pollution. Since it is impractical to restore all pollution problems, the proper use of some remedial measures, under the guidance of functional orientation, may be sufficient to minimize the risk of persistent and diffusing pollutants. In recent years, bioremediation technology has been gradually developed into a promising stage and has played a crucial role in the degradation of heavy oil pollution. Specially, microbes in the degradation of heavy oil have made a great contribution. This paper mainly summarizes the different kinds of microorganisms for degrading heavy oil and the detection method for degradation efficiency of heavy oil pollution.

  5. A Novel Degradation Identification Method for Wind Turbine Pitch System

    NASA Astrophysics Data System (ADS)

    Guo, Hui-Dong

    2018-04-01

    It’s difficult for traditional threshold value method to identify degradation of operating equipment accurately. An novel degradation evaluation method suitable for wind turbine condition maintenance strategy implementation was proposed in this paper. Based on the analysis of typical variable-speed pitch-to-feather control principle and monitoring parameters for pitch system, a multi input multi output (MIMO) regression model was applied to pitch system, where wind speed, power generation regarding as input parameters, wheel rotation speed, pitch angle and motor driving currency for three blades as output parameters. Then, the difference between the on-line measurement and the calculated value from the MIMO regression model applying least square support vector machines (LSSVM) method was defined as the Observed Vector of the system. The Gaussian mixture model (GMM) was applied to fitting the distribution of the multi dimension Observed Vectors. Applying the model established, the Degradation Index was calculated using the SCADA data of a wind turbine damaged its pitch bearing retainer and rolling body, which illustrated the feasibility of the provided method.

  6. Peptide Identification by Database Search of Mixture Tandem Mass Spectra*

    PubMed Central

    Wang, Jian; Bourne, Philip E.; Bandeira, Nuno

    2011-01-01

    In high-throughput proteomics the development of computational methods and novel experimental strategies often rely on each other. In certain areas, mass spectrometry methods for data acquisition are ahead of computational methods to interpret the resulting tandem mass spectra. Particularly, although there are numerous situations in which a mixture tandem mass spectrum can contain fragment ions from two or more peptides, nearly all database search tools still make the assumption that each tandem mass spectrum comes from one peptide. Common examples include mixture spectra from co-eluting peptides in complex samples, spectra generated from data-independent acquisition methods, and spectra from peptides with complex post-translational modifications. We propose a new database search tool (MixDB) that is able to identify mixture tandem mass spectra from more than one peptide. We show that peptides can be reliably identified with up to 95% accuracy from mixture spectra while considering only a 0.01% of all possible peptide pairs (four orders of magnitude speedup). Comparison with current database search methods indicates that our approach has better or comparable sensitivity and precision at identifying single-peptide spectra while simultaneously being able to identify 38% more peptides from mixture spectra at significantly higher precision. PMID:21862760

  7. Covalently Linked Tandem Lesions in DNA

    PubMed Central

    Patrzyc, Helen B.; Dawidzik, Jean B.; Budzinski, Edwin E.; Freund, Harold G.; Wilton, John H.; Box, Harold C.

    2013-01-01

    Reactive oxygen species (ROS) generate a type of DNA damage called tandem lesions, two adjacent nucleotides both modified. A subcategory of tandem lesions consists of adjacent nucleotides linked by a covalent bond. Covalently linked tandem lesions generate highly characteristic liquid chromotography-tandem mass spectrometry (LC-MS/MS) elution profiles. We have used this property to comprehensively survey X-irradiated DNA for covalently linked tandem lesions. A total of 15 tandem lesions were detected in DNA irradiated in deoxygenated aqueous solution, five tandem lesions were detected in DNA that was irradiated in oxygenated solution. PMID:23106212

  8. Effect of different oxytetracycline addition methods on its degradation behavior in soil.

    PubMed

    Chen, Gui-Xiu; He, Wei-Wei; Wang, Yan; Zou, Yong-De; Liang, Juan-Boo; Liao, Xin-Di; Wu, Yin-Bao

    2014-05-01

    The degradation behavior of veterinary antibiotics in soil is commonly studied using the following methods of adding antibiotics to the soil: (i) adding manure collected from animals fed with a diet containing antibiotics, (ii) adding antibiotic-free animal manure spiked with antibiotics and (iii) directly adding antibiotics. No research simultaneously comparing different antibiotic addition methods was found. Oxytetracycline (OTC) was used as a model antibiotic to compare the effect of the three commonly used antibiotic addition methods on OTC degradation behavior in soil. The three treatment methods have similar trends, though OTC degradation half-lives show the following significant differences (P<0.05): manure from swine fed OTC (treatment A)degradation. The treatments presenting manure (A and B) significantly enhanced EC, enzyme activity, microbial biomass carbon and nitrogen when compared to the treatment without manure (C), thus increasing degradation of OTC in the soil. Because the main entry route for veterinary antibiotics into soil is via the manure of animals given with antibiotics, the most appropriate method to study the degradation and ecotoxicity of antibiotic residues in soil may be to use manure from animals that are given a particular antibiotic, rather than by adding it directly to the soil. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Study on degrading graphene oxide in wastewater under different conditions for developing an efficient and economical degradation method.

    PubMed

    Li, Ting; Zhang, Chao-Zhi; Gu, Chengyue

    2017-12-01

    With popular application of graphene and graphene oxide (GO), they have been discharged into water. Graphene and GO harm organisms. However, an efficient and economical method for removing graphene and GO in wastewater has seldom been reported. Graphene can be oxidized by hydrogen peroxide to give GO; therefore, degradation of graphene oxide is an important step in the procedure of removal of graphene from water. In this paper, GO degradation via photo-Fenton reaction under different conditions was carried out. Experimental results suggested that GO in wastewater can be efficiently and economically degraded into carbon dioxide and H 2 O when pH value is 3, concentration of H 2 O 2 and FeCl 3 are 35 mM and 5 ppm, respectively. Degradation mechanism of GO was suggested based on UV-vis absorption spectra, scanning electron microscopy, X-ray diffraction and liquid chromatography-mass spectra data of degradation intermediates. This paper suggests an efficient and economical degradation way of GO in wastewater.

  10. Comparison of oxytetracycline degradation behavior in pig manure with different antibiotic addition methods.

    PubMed

    Wang, Yan; Chen, Guixiu; Liang, Juanboo; Zou, Yongde; Wen, Xin; Liao, Xindi; Wu, Yinbao

    2015-12-01

    Using manure collected from swine fed with diet containing antibiotics and antibiotic-free swine manure spiked with antibiotics are the two common methods of studying the degradation behavior of veterinary antibiotic in manure in the environment. However, few studies had been conducted to co-compare these two different antibiotic addition methods. This study used oxytetracycline (OTC) as a model antibiotic to study antibiotic degradation behavior in manure under the above two OTC addition methods. In addition, the role of microorganisms present in the manure on degradation behavior was also examined. The results showed that degradation half-life of OTC in manure from swine fed OTC (9.04 days) was significantly shorter than that of the manure directly treated with OTC (9.65 days). Concentration of 4-epi-OTC in manure from swine fed OTC peaked earlier than that in manure spiked with OTC, and the degradation rates of 4-epi-OTC and α-apo-OTC in the manure from swine fed OTC were faster, but the peak concentrations were lower, than those in manure spiked with OTC. Bacterial diversity and relative abundance of Bacillus cereus data demonstrated that sterilization of the manure before experiment significantly decreased OTC degradation rate in both of the addition methods. Results of the present study demonstrated that the presence of the metabolites (especially 4-epi-OTC) and microorganisms had significant influence on OTC degradation.

  11. Electrical and optical analyses of tandem organic light-emitting diodes with organic charge-generation layer

    NASA Astrophysics Data System (ADS)

    Kim, Bong Sung; Chae, Heeyeop; Chung, Ho Kyoon; Cho, Sung Min

    2018-06-01

    The electrical and optical properties of tandem organic light-emitting diodes (OLEDs), in which a fluorescent and phosphorescent emitting units are connected by an organic charge-generation layer (CGL), were experimentally analyzed. To investigate the internal properties of the tandem OLEDs, we fabricated and compared two single, two homo-tandem, and two hetero-tandem OLEDs using the fluorescent and phosphorescent units. From the experimental results of the OLEDs obtained at the same current density, the voltage across the CGL as well as the individual emission spectra and luminance of each unit of tandem OLEDs were obtained and compared with the theoretical simulation results. The analysis method proposed in this study can be utilized as a method to verify the accuracy of optical or electrical computer simulation of tandem OLED and it will be useful to understand the overall electrical and optical characteristics of tandem OLEDs.

  12. Degradation of trimethoprim by gamma irradiation in the presence of persulfate

    NASA Astrophysics Data System (ADS)

    Zhang, Zhonglei; Yang, Qi; Wang, Jianlong

    2016-10-01

    The degradation and mineralization of trimethoprim (TMP) by gamma irradiation was investigated in the presence of persulfate (PS). The TMP was degraded at initial concentration of 20 mg/L in aqueous solution with addition of 0, 0.5, 1, 1.5, 2 mM persulfate respectively. The effect of pH values (6.5, 7.5 and 8.5) on TMP degradation was also determined. The experimental results showed that the degradation and mineralization of TMP could be significantly enhanced by persulfate at acidic condition (pH=6.5). Several intermediate products generated during gamma irradiation process through hydroxylation, demethylation and cleavage were identified using liquid chromatography with tandem mass spectrometry (HPLC-MS). The degradation pathway of TMP was tentatively proposed based on the identification of intermediate products.

  13. A validated stability-indicating RP-HPLC method for levofloxacin in the presence of degradation products, its process related impurities and identification of oxidative degradant.

    PubMed

    Lalitha Devi, M; Chandrasekhar, K B

    2009-12-05

    The objective of current study was to develop a validated specific stability indicating reversed-phase liquid chromatographic method for the quantitative determination of levofloxacin as well as its related substances determination in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its process related impurities. Forced degradation studies were performed on bulk sample of levofloxacin as per ICH prescribed stress conditions using acid, base, oxidative, water hydrolysis, thermal stress and photolytic degradation to show the stability indicating power of the method. Significant degradation was observed during oxidative stress and the degradation product formed was identified by LCMS/MS, slight degradation in acidic stress and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies and the impurity spiked solution. Good resolution between the peaks corresponds to process related impurities and degradation products from the analyte were achieved on ACE C18 column using the mobile phase consists a mixture of 0.5% (v/v) triethyl amine in sodium dihydrogen orthophosphate dihydrate (25 mM; pH 6.0) and methanol using a simple linear gradient. The detection was carried out at 294 nm. The limit of detection and the limit of quantitation for the levofloxacin and its process related impurities were established. The stressed test solutions were assayed against the qualified working standard of levofloxacin and the mass balance in each case was in between 99.4 and 99.8% indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of levofloxacin at the time of batch release and also during its stability studies (long term and accelerated stability).

  14. Stability-Indicating HPTLC Method for Studying Stress Degradation Behavior of Sulbutiamine HCl

    PubMed Central

    Farid, Nehal F.; Abdelwahab, Nada S.

    2016-01-01

    Sulbutiamine (SUL) is an ester of thiazides with neurotropic action. A new stability indicating HPTLC method has been developed and validated for the determination of SUL in the presence of different degradation products. The drug was subjected to different stress conditions following ICH strategy such as hydrolytic degradation (neutral, alkaline and acidic hydrolysis), oxidation, photodegradation and dry heat degradation. The drug demonstrated degradation under all decomposition conditions except neutral hydrolysis and dry heat, where the drug was completely degraded with 0.1 N NaOH, 1 N HCl and 30% H2O2 while it was partially degradaed by 0.1 N HCl, 3% H2O2 and UV light. Structure elucidation of the resulting degradation products was performed using ESI-Q-MS–MS. A well-defined peak for SUL was obtained at Rf = 0.46 and was completely separated from all obtained degradation products. Chromatographic separation was carried out on HPTLC aluminum plates precoated with silica gel 60 F254 using acetone–methylene chloride–ammonia buffer (pH 8.5 ± 0.2) (7:3:0.5, v/v) as a developing system. Densitometric scanning of the separated peaks was performed at 254 nm. System suitability testing parameters were calculated to ascertain the quality performance of the developed method. The method was validated with respect to USP guidelines regarding accuracy, precision, specificity, robustness and ruggedness. Good correlation coefficients were achieved in the range of 0.4–5.0 µg/band, and the limit of detection and limit of quantitation were found to be 0.11 and 0.33 µg/band, respectively. The utility of the suggested method was verified by application to Arcalion forte® tablets where no interference from additives was found. PMID:26759487

  15. Stability-Indicating HPTLC Method for Studying Stress Degradation Behavior of Sulbutiamine HCl.

    PubMed

    Farid, Nehal F; Abdelwahab, Nada S

    2016-04-01

    Sulbutiamine (SUL) is an ester of thiazides with neurotropic action. A new stability indicating HPTLC method has been developed and validated for the determination of SUL in the presence of different degradation products. The drug was subjected to different stress conditions following ICH strategy such as hydrolytic degradation (neutral, alkaline and acidic hydrolysis), oxidation, photodegradation and dry heat degradation. The drug demonstrated degradation under all decomposition conditions except neutral hydrolysis and dry heat, where the drug was completely degraded with 0.1 N NaOH, 1 N HCl and 30% H2O2 while it was partially degradaed by 0.1 N HCl, 3% H2O2 and UV light. Structure elucidation of the resulting degradation products was performed using ESI-Q-MS-MS. A well-defined peak for SUL was obtained at Rf = 0.46 and was completely separated from all obtained degradation products. Chromatographic separation was carried out on HPTLC aluminum plates precoated with silica gel 60 F254 using acetone-methylene chloride-ammonia buffer (pH 8.5 ± 0.2) (7:3:0.5, v/v) as a developing system. Densitometric scanning of the separated peaks was performed at 254 nm. System suitability testing parameters were calculated to ascertain the quality performance of the developed method. The method was validated with respect to USP guidelines regarding accuracy, precision, specificity, robustness and ruggedness. Good correlation coefficients were achieved in the range of 0.4-5.0 µg/band, and the limit of detection and limit of quantitation were found to be 0.11 and 0.33 µg/band, respectively. The utility of the suggested method was verified by application to Arcalion forte® tablets where no interference from additives was found. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Studies of the Lateral-Directional Flying Qualities of a Tandem Helicopter in Forward Flight

    NASA Technical Reports Server (NTRS)

    Amer, Kenneth B; Tapscott, Robert J

    1954-01-01

    An investigation of the lateral-directional flying qualities of a tandem-rotor helicopter in forward flight was undertaken to determine desirable goals for helicopter lateral-directional flying qualities and possible methods of achieving these goals in the tandem-rotor helicopter. Comparison between directional stability as measured in flight and rotor-off model tests in a wind tunnel shows qualitative agreement and, hence, indicates such wind-tunnel test, despite the absence of the rotors, to be one effective method of studying means of improving the directional stability of the tandem helicopter. Flight-test measurements of turns and oscillations, in conjunction with analytical studies, suggest possible practical methods of achieving the goals of satisfactory turn and oscillatory characteristics in the tandem helicopter.

  17. Development of a UHPLC-MS/MS method for the measurement of chlortetracycline degradation in swine manure

    USDA-ARS?s Scientific Manuscript database

    An ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed capable of simultaneously measuring chlortetracycline (CTC), epi-chlortetracycline (epi-CTC), isochlortetracycline (ICTC), oxytetracycline, and tetracycline in swine manure. A simple sample pr...

  18. Orthogonal tandem catalysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lohr, Tracy L.; Marks, Tobin J.

    2015-05-20

    Tandem catalysis is a growing field that is beginning to yield important scientific and technological advances toward new and more efficient catalytic processes. 'One-pot' tandem reactions, where multiple catalysts and reagents, combined in a single reaction vessel undergo a sequence of precisely staged catalytic steps, are highly attractive from the standpoint of reducing both waste and time. Orthogonal tandem catalysis is a subset of one-pot reactions in which more than one catalyst is used to promote two or more mechanistically distinct reaction steps. This Perspective summarizes and analyses some of the recent developments and successes in orthogonal tandem catalysis, withmore » particular focus on recent strategies to address catalyst incompatibility. We also highlight the concept of thermodynamic leveraging by coupling multiple catalyst cycles to effect challenging transformations not observed in single-step processes, and to encourage application of this technique to energetically unfavourable or demanding reactions.« less

  19. Adaptation of the Conditions of US EPA Method 538 for the ...

    EPA Pesticide Factsheets

    Report The objective of this study was to evaluate U.S. EPA’s Method 538 for the assessment of drinking water exposure to the nerve agent degradation product, EA2192, the most toxic degradation product of nerve agent VX. As a result of the similarities in sample preparation and analysis that Method 538 uses for nonvolatile chemicals, this method is applicable to the nonvolatile Chemical Warfare Agent (CWA) degradation product, EA2192, in drinking water. The method may be applicable to other nonvolatile CWAs and their respective degradation products as well, but the method will need extensive testing to verify compatibility. Gaps associated with the need for analysis methods capable of analyzing such analytes were addressed by adapting the EPA 538 method for this CWA degradation product. Many laboratories have the experience and capability to run the already rigorous method for nonvolatile compounds in drinking water. Increasing the number of laboratories capable of carrying out these methods serves to significantly increase the surge laboratory capacity to address sample throughput during a large exposure event. The approach desired for this study was to start with a proven high performance liquid chromatography tandem mass spectrometry (HPLC/MS/MS) method for nonvolatile chemicals in drinking water and assess the inclusion of a similar nonvolatile chemical, EA2192.

  20. Development of a UHPLC-MS/MS method for the measurement of chlortetracycline degradation in swine manure

    USDA-ARS?s Scientific Manuscript database

    An ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed capable of simultaneously measuring chlortetracycline (CTC), epi-chlortetracycline (epi-CTC) and isochlortetracycline (ICTC), as well as other structurally related tetracyclines in swine manur...

  1. Method for modeling the gradual physical degradation of a porous material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flach, Greg

    Cementitious and other engineered porous materials encountered in waste disposals may degrade over time due to one or more mechanisms. Physical degradation may take the form of cracking (fracturing) and/or altered (e.g. increased) porosity, depending on the material and underlying degradation mechanism. In most cases, the hydraulic properties of degrading materials are expected to evolve due to physical changes occurring over roughly the pore to decimeter scale, which is conducive to calculating equivalent or effective material properties. The exact morphology of a degrading material in its end-state may or may not be known. In the latter case, the fully-degraded conditionmore » can be assumed to be similar to a more-permeable material in the surrounding environment, such as backfill soil. Then the fully-degraded waste form or barrier material is hydraulically neutral with respect to its surroundings, constituting neither a barrier to nor conduit for moisture flow and solute transport. Unless the degradation mechanism is abrupt, a gradual transition between the intact initial and fully-degraded final states is desired. Linear interpolation through time is one method for smoothly blending hydraulic properties between those of an intact matrix and those of a soil or other surrogate for the end-state.« less

  2. Characterization of degradation products of silodosin under stress conditions by liquid chromatography/Fourier transform mass spectrometry.

    PubMed

    Pandeti, Sukanya; Narender, Tadigoppula; Prabhakar, Sripadi; Reddy, Thota Jagadeswar

    2017-03-30

    Silodosin (SDN) is a novel α 1 -adrenoceptor antagonist in the treatment of benign prostatic hyperplasia (BPH). The presence of degradation products in a drug affects not only the quality, but also the safety and efficacy of drug formulation. Thus, it is essential to develop an efficient analytical method which could be useful to selectively separate, identify and characterise of all possible degradation products of SDN which is mandatory in drug development processes. SDN was subjected to forced degradation under hydrolytic (acid, base and neutral), oxidative, photolytic and thermal stress conditions. Separation of the drug and degradation products was achieved by a liquid chromatography (LC) method using an Acquity UPLC® BEH C18 (2.1 × 100 mm, 1.7 μm; Waters) column with mobile phase consisting of 0.1% formic acid (FA) in water (A) and 0.1% FA in acetonitrile (ACN) and methanol (MeOH) (1:1) (B) as organic modifier at a flow rate of 0.15 mL min -1 in gradient elution mode. Identification and characterization of the degradation products was performed by mass spectrometry methods using an LTQ-Orbitrap mass spectrometer. A total of five degradation products (DP1 to DP5) were formed under various stress conditions and their structures were proposed with the help of tandem mass spectrometry (MS/MS) experiments and high-resolution mass spectral data. A common degradation product (DP1) was observed under acidic and basic degradation conditions. DP2 was observed under acidic, DP4 and DP5 were observed under basic hydrolytic conditions, whereas DP3 was observed under oxidative conditions. SDN was found to be labile under hydrolytic and oxidative conditions. The structures of all the degradation products were proposed. The most rational mechanisms for the formation of the degradation products under different stress conditions have been established. The proposed method can be effectively used to carry out the determination and detection of SDN and its degradation

  3. Targeted tandem duplication of a large chromosomal segment in Aspergillus oryzae.

    PubMed

    Takahashi, Tadashi; Sato, Atsushi; Ogawa, Masahiro; Hanya, Yoshiki; Oguma, Tetsuya

    2014-08-01

    We describe here the first successful construction of a targeted tandem duplication of a large chromosomal segment in Aspergillus oryzae. The targeted tandem chromosomal duplication was achieved by using strains that had a 5'-deleted pyrG upstream of the region targeted for tandem chromosomal duplication and a 3'-deleted pyrG downstream of the target region. Consequently,strains bearing a 210-kb targeted tandem chromosomal duplication near the centromeric region of chromosome 8 and strains bearing a targeted tandem chromosomal duplication of a 700-kb region of chromosome 2 were successfully constructed. The strains bearing the tandem chromosomal duplication were efficiently obtained from the regenerated protoplast of the parental strains. However, the generation of the chromosomal duplication did not depend on the introduction of double-stranded breaks(DSBs) by I-SceI. The chromosomal duplications of these strains were stably maintained after five generations of culture under nonselective conditions. The strains bearing the tandem chromosomal duplication in the 700-kb region of chromosome 2 showed highly increased protease activity in solid-state culture, indicating that the duplication of large chromosomal segments could be a useful new breeding technology and gene analysis method.

  4. A novel high-throughput method for supported liquid extraction of retinol and alpha-tocopherol from human serum and simultaneous quantitation by liquid chromatography tandem mass spectrometry.

    PubMed

    Hinchliffe, Edward; Rudge, James; Reed, Paul

    2016-07-01

    Measurement of vitamin A (retinol) and E (alpha-tocopherol) in UK clinical laboratories is currently performed exclusively by high-performance liquid chromatography with ultraviolet detection. We investigated whether retinol and alpha-tocopherol could be measured simultaneously by liquid chromatography tandem mass spectrometry. Serum samples (100 μL) were extracted using Isolute + Supported Liquid Extraction plates. Chromatography was performed on a Phenomenex Kinetex Biphenyl 2.6 μm, 50 × 2.1 mm column, and liquid chromatography tandem mass spectrometry on a Waters Acquity TQD. Injection-to-injection time was 4.3 min. The assay was validated according to published guidelines. Patient samples were used to compare liquid chromatography tandem mass spectrometry and high-performance liquid chromatography with ultraviolet detection methods. For retinol and alpha-tocopherol, respectively, the assay was linear up to 6.0 and 80.0 μmol/L, and lower limit of quantification was 0.07 and 0.26 μmol/L. Intra and interassay imprecision were within desirable analytical specifications. Analysis of quality control material aligned to NIST SRM 968e, and relative spiked recovery from human serum, both yielded results within 15% of target values. Method comparison with high-performance liquid chromatography with ultraviolet detection methodology demonstrated a negative bias for retinol and alpha-tocopherol by the liquid chromatography tandem mass spectrometry method. Analysis of United Kingdom National External Quality Assurance Scheme samples yielded mean bias from the target value of +3.0% for retinol and -11.2% for alpha-tocopherol. We have developed a novel, high-throughput method for extraction of retinol and alpha-tocopherol from human serum followed by simultaneous quantitation by liquid chromatography tandem mass spectrometry. The method offers a rapid, sensitive, specific and cost-effective alternative to high-performance liquid chromatography with

  5. Methods and reagents. Degraded DNA and gel tornados.

    PubMed

    Hengen, P N

    1997-04-01

    Methods and reagents is a unique monthly column that highlights current discussions in the newsgroup bionet.molbio.methds-reagnts, available on the Internet. This month's column discusses a case of inexplicable DNA degradation and tornados seen in agarose gels. For details on how to partake in the newsgroup, see the accompanying box.

  6. Degradation of fluoroquinolone antibiotics and identification of metabolites/transformation products by liquid chromatography-tandem mass spectrometry.

    PubMed

    Maia, Alexandra S; Ribeiro, Ana R; Amorim, Catarina L; Barreiro, Juliana C; Cass, Quezia B; Castro, Paula M L; Tiritan, Maria Elizabeth

    2014-03-14

    Antibiotics are a therapeutic class widely found in environmental matrices and extensively studied due to its persistence and implications for multi-resistant bacteria development. This work presents an integrated approach of analytical multi-techniques on assessing biodegradation of fluorinated antibiotics at a laboratory-scale microcosmos to follow removal and formation of intermediate compounds. Degradation of four fluoroquinolone antibiotics, namely Ofloxacin (OFL), Norfloxacin (NOR), Ciprofloxacin (CPF) and Moxifloxacin (MOX), at 10 mg L(-1) using a mixed bacterial culture, was assessed for 60 days. The assays were followed by a developed and validated analytical method of LC with fluorescence detection (LC-FD) using a Luna Pentafluorophenyl (2) 3 μm column. The validated method demonstrated good selectivity, linearity (r(2)>0.999), intra-day and inter-day precisions (RSD<2.74%) and accuracy. The quantification limits were 5 μg L(-1) for OFL, NOR and CPF and 20 μg L(-1) for MOX. The optimized conditions allowed picturing metabolites/transformation products formation and accumulation during the process, stating an incomplete mineralization, also shown by fluoride release. OFL and MOX presented the highest (98.3%) and the lowest (80.5%) extent of degradation after 19 days of assay, respectively. A representative number of samples was selected and analyzed by LC-MS/MS with triple quadrupole and the molecular formulas were confirmed by a quadruple time of flight analyzer (QqTOF). Most of the intermediates were already described as biodegradation and/or photodegradation products in different conditions; however unknown metabolites were also identified. The microbial consortium, even when exposed to high levels of FQ, presented high percentages of degradation, never reported before for these compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Novel methods for the quantification of (2E)-hexadecenal by liquid chromatography with detection by either ESI QTOF tandem mass spectrometry or fluorescence measurement.

    PubMed

    Lüth, Anja; Neuber, Corinna; Kleuser, Burkhard

    2012-04-13

    Sphingosine-1-phosphate lyase (SPL) is the only known enzyme that irreversibly cleaves sphingosine-1-phosphate (S1P) into phosphoethanolamine and (2E)-hexadecenal during the final step of sphingolipid catabolism. Because S1P is involved in a wide range of physiological and diseased processes, determining the activity of the degrading enzyme is of great interest. Therefore, we developed two procedures based on liquid chromatography (LC) for analysing (2E)-hexadecenal, which is one of the two S1P degradation products. After separation, two different quantification methods were performed, tandem mass spectrometry (MS) and fluorescence detection. However, (2E)-hexadecenal as a long-chain aldehyde is not ionisable by electrospray ionisation (ESI) for MS quantification and has an insufficient number of corresponding double bonds for fluorescence detection. Therefore, we investigated 2-diphenylacetyl-1,3-indandione-1-hydrazone (DAIH) as a derivatisation reagent. DAIH transforms the aldehyde into an ionisable and fluorescent analogue for quantitative analysis. Our conditions were optimised to obtain the outstanding limit of detection (LOD) of 1 fmol per sample (30 μL) for LC-MS/MS and 0.75 pmol per sample (200 μL) for LC determination with fluorescence detection. We developed an extraction procedure to separate and concentrate (2E)-hexadecenal from biological samples for these measurements. To confirm our new methods, we analysed the (2E)-hexadecenal level of different cell lines and human plasma for the first time ever. Furthermore, we treated HT-29 cells with different concentrations of 4-deoxypyridoxine (DOP), which competitively inhibits pyridoxal-5-phosphate (P5P), an essential cofactor for SPL activity, and observed a significant decrease in (2E)-hexadecenal relative to the untreated cells. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. The application of magnetic bead hybridization for the recovery and STR amplification of degraded and inhibited forensic DNA.

    PubMed

    Wang, Jing; McCord, Bruce

    2011-06-01

    A common problem in the analysis of forensic DNA evidence is the presence of environmentally degraded and inhibited DNA. Such samples produce a variety of interpretational problems such as allele imbalance, allele dropout and sequence specific inhibition. In an attempt to develop methods to enhance the recovery of this type of evidence, magnetic bead hybridization has been applied to extract and preconcentrate DNA sequences containing short tandem repeat (STR) alleles of interest. In this work, genomic DNA was fragmented by heating, and sequences associated with STR alleles were selectively hybridized to allele-specific biotinylated probes. Each particular biotinylated probe-DNA complex was bound to streptavidin-coated magnetic beads using enabling enrichment of target DNA sequences. Experiments conducted using degraded DNA samples, as well as samples containing a large concentration of inhibitory substances, showed good specificity and recovery of missing alleles. Based on the favorable results obtained with these specific probes, this method should prove useful as a tool to improve the recovery of alleles from degraded and inhibited DNA samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Achieving 15% Tandem Polymer Solar Cells

    DTIC Science & Technology

    2015-06-23

    solar cell structures – both polymer only and hybrid tandem cells to constantly pushing the envelope of solution processed solar cell ...performance – 11.6% polymer tandem cell , 7% transparent tandem polymer cell , and over 10% PCE hybrid tandem solar cells were achieved. In addition, AFOSR’s...final support also enabled us to explore novel hybrid perovskite solar cells in depth. For example, single junction cell efficiency

  10. CREATININE DETERMINATION IN URINE BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION-TANDEM MASS SPECTROMETRY METHOD.

    PubMed

    Dereziński, Paweł; Klupczyńska, Agnieszka; Sawicki, Wojciech; Kokot, Zenon J

    2016-01-01

    Creatinine determination in urine is used to estimate the completeness of the 24-h urine collection, compensation for variable diuresis and as a preliminary step in protein profiling in urine. Despite the fact that a wide range of methods of measuring creatinine level in biofluids has been developed, many of them are adversely affected by interfering substances. A new liquid chromatography-tandem mass spectrometry method for creatinine determination in urine has been developed. Chromatographic separation was performed by applying C18 column and a gradient elution. Analyses were carried out on a triple quadrupole mass spectrometer equipped with an electrospray ion source. The developed method was fully validated according to the international guidelines. The quantification range of the method was 5-1500 ng/mL, which corresponds to 1-300 mg/dL in urine. Limit of detection and quantitation were 2 and 5 ng/mL, respectively. Additionally, the comparison of creatinine determination by newly developed method to the colorimetric method was performed. The method enables the determination of creatinine in urine samples with a minimal sample preparation, excellent sensitivity and prominent selectivity. Since mass spectrometry allows to measure a number of compounds simultaneously, a future perspective would be to incorporate the determination of other clinically important compounds excreted in urine.

  11. Quantitation of phlorizin and phloretin using an ultra high performance liquid chromatography-electrospray ionization tandem mass spectrometric method.

    PubMed

    Lijia, Xu; Guo, Jianru; Chen, QianQian; Baoping, Jiang; Zhang, Wei

    2014-06-01

    A sensitive and selective ultra high performance liquid chromatography-tandem mass spectrometric (UHPLC-MS/MS) method for the determination of phlorizin and phloretin in human plasma has been firstly developed. Samples were prepared after protein precipitation and analyzed on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. Negative electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile-water (0.02% formic acid), using a gradient procedure. The analytes and internal standard dihydroquercetin were both detected by use of multiple reaction monitoring mode. The method was linear in the concentration range of 2.5-1000.0 ng/mL. The lower limit of quantification (LLOQ) was 2.5 ng/mL. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 9.2%. The accuracy determined at three concentrations was within ± 7.3% in terms of relative error. The total run time was 12.0 min. This assay offers advantages in terms of expediency, and suitability for the analysis of phlorizin and phloretin in various biological fluids. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Single Laboratory Validated Method for Determination of Cylindrospermopsin and Anatoxin-a in Ambient Freshwaters by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)

    EPA Pesticide Factsheets

    This document is a standardized single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection and quantification of cyanotoxins (combined intracellular and extracellular) in ambient freshwaters.

  13. A stability indicating HPLC method for determination of mebeverine in the presence of its degradation products and kinetic study of its degradation in oxidative condition

    PubMed Central

    Souri, E.; Aghdami, A. Negahban; Adib, N.

    2014-01-01

    An HPLC method for determination of mebeverine hydrochloride (MH) in the presence of its degradation products was developed. The degradation of MH was studied under hydrolysis, oxidative and photolysis stress conditions. Under alkaline, acidic and oxidative conditions, degradation of MH was observed. The separation was performed using a Symmetry C18 column and a mixture of 50 mM KH2PO4, acetonitrile and tetrahydrfuran (THF) (63:35:2; v/v/v) as the mobile phase. No interference peaks from degradation products in acidic, alkaline and oxidative conditions were observed. The linearity, accuracy and precision of the method were studied. The method was linear over the range of 1-100 μg/ml MH (r2>0.999) and the CV values for intra-day and inter-day variations were in the range of 1.0-1.8%. The limit of quantification (LOQ) and the limit of detection (LOD) of the method were 1.0 and 0.2 μg/ml, respectively. Determination of MH in pharmaceutical dosage forms was performed using the developed method. Furthermore the kinetics of the degradation of MH in the presence of hydrogen peroxide was investigated. The proposed method could be a suitable method for routine quality control studies of mebeverine dosage forms. PMID:25657790

  14. A stability indicating HPLC method for determination of mebeverine in the presence of its degradation products and kinetic study of its degradation in oxidative condition.

    PubMed

    Souri, E; Aghdami, A Negahban; Adib, N

    2014-01-01

    An HPLC method for determination of mebeverine hydrochloride (MH) in the presence of its degradation products was developed. The degradation of MH was studied under hydrolysis, oxidative and photolysis stress conditions. Under alkaline, acidic and oxidative conditions, degradation of MH was observed. The separation was performed using a Symmetry C18 column and a mixture of 50 mM KH2PO4, acetonitrile and tetrahydrfuran (THF) (63:35:2; v/v/v) as the mobile phase. No interference peaks from degradation products in acidic, alkaline and oxidative conditions were observed. The linearity, accuracy and precision of the method were studied. The method was linear over the range of 1-100 μg/ml MH (r(2)>0.999) and the CV values for intra-day and inter-day variations were in the range of 1.0-1.8%. The limit of quantification (LOQ) and the limit of detection (LOD) of the method were 1.0 and 0.2 μg/ml, respectively. Determination of MH in pharmaceutical dosage forms was performed using the developed method. Furthermore the kinetics of the degradation of MH in the presence of hydrogen peroxide was investigated. The proposed method could be a suitable method for routine quality control studies of mebeverine dosage forms.

  15. METHOD 544. DETERMINATION OF MICROCYSTINS AND NODULARIN IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    EPA Science Inventory

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...

  16. Novel amphiphilic polymeric ionic liquid-solid phase micro-extraction membrane for the preconcentration of aniline as degradation product of azo dye Orange G under sonication by liquid chromatography-tandem mass spectrometry.

    PubMed

    Cai, Mei-Qiang; Wei, Xiao-Qing; Du, Chun-Hui; Ma, Xu-Ming; Jin, Mi-Cong

    2014-07-04

    A novel amphiphilic polymeric ionic liquid membrane containing a hydrophilic bromide anion and a hydrophobic carbonyl group was synthesized in dimethylformamide (DMF) systems using the ionic liquid 1-butyl-3-vinylimidazolium bromide (BVImBr) and the methylmethacrylate (MMA) as monomers. The prepared amphiphilic ploy-methylmethacrylate-1-butyl-3-vinylimidazolium bromide (MMA-BVImBr) was characterized by a scanning electron microscope and an infrared spectrum instrument. The results of solid-phase micro-extraction membrane (SPMM) experiments showed that the adsorption capacity of membrane was about 0.76μgμg(-1) for aniline. Based on this, a sensitive method for the determination of trace aniline, as a degradation product of azo dye Orange G under sonication, was developed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The calibration curve showed a good linearity ranging from 0.5 to 10.0μgL(-1) with a correlation coefficient value of 0.9998. The limit of quantification was 0.5μgL(-1). The recoveries ranged from 90.6% to 96.1%. The intra- and inter-day relative standard deviations were less than 8.3% and 10.9%. The developed SPMM-LC-MS/MS method was used successfully for preconcentration of trace aniline produced during the sonication of Orange G solution. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. A novel method for the determination of glycidyl and 3-monochloropropanediol esters in fish oil by gas chromatography tandem mass spectrometry.

    PubMed

    Garballo-Rubio, A; Soto-Chinchilla, J; Moreno, A; Zafra-Gómez, A

    2017-04-01

    Today, food security is one of the most important global issues with food quality control and identification of contaminants in foods and beverages, being crucial for human health and safety. In this paper, a novel single-step method for the simultaneous determination of 3-monochloropropanediol (3-MCPD) and glycidyl esters in samples of winterized and non-winterized fish oil by using gas chromatography tandem mass spectrometry (GC-MS/MS) is validated. The method is based on alkaline hydrolysis of esters at room temperature, using only 3-MCPD-d5 as internal standard, and a derivatization step with phenylboronic acid (PBA) at 90°C. The use of GC-MS/MS results in a simplified sample treatment and improvement of the limits of quantification and precision of the analytical method with no need of additional concentration of the extracts. A backflush tee placed between two HP-5 MS UI columns (15m×0.25µm×0.25mm) was used in order to minimize matrix effects and peak shape degradation usually observed in routine analyses. The method was validated in winterized and non-winterized fish oil, achieving a limit of quantification of 100ngg -1 and 50ngg -1 for 3-MCPD and glycidol, respectively. Method validation was accomplished by comparing our laboratory results with results obtained by an accredited reference laboratory (SGS Germany GmbH) and by calculating the recoveries obtained in an assay with spiked samples. For glycidol quantification, a mathematical equation was developed in order to compensate for the partial conversion of 3-MCPD into glycidol. This expression involves the quantification of 3-MBPD-d5 generated during hydrolysis reaction. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Measurement of pyrethroids and their environmental degradation products in fresh fruits and vegetables using a modification of the quick easy cheap effective rugged safe (QuEChERS) method.

    PubMed

    Li, Weiwei; Morgan, Marsha K; Graham, Stephen E; Starr, James M

    2016-05-01

    Pyrethroid insecticides are used extensively in agriculture, and they, as well as their environmental degradates, may remain as residues on foods such as fruits and vegetables. Since pyrethroid degradates can be identical to the urinary markers used in human biomonitoring, it is important to understand the contribution of these degradates when studying sources of human pyrethroid exposure. We modified the widely used Quick Easy Cheap Effective Rugged Safe (QuEChERS) method to measure several current-use pyrethroids (cis/trans-permethrin, cypermethrin, deltamethrin, esfenvalerate, bifenthrin, cyfluthrin, and cyhalothrin) and their environmental degradation products (3-PBA, cis/trans-DCCA, 4-F-3-PBA, DBCA, and MPA) in selected fresh fruits and vegetables. Using fortified samples, we determined extraction efficiencies from: tomatoes, oranges (whole, peeled, and rind), grapes, apples, bananas (peeled and rind only), onions, lettuce, green peppers, carrots and broccoli. For a subset of these food items (apples, grapes, tomatoes, lettuce and banana peel), we also established limits of detection (MDLs) and quantitation (MQLs). Each sample was homogenized (1kg) then spiked with the target pyrethroids and their degradation products. Sub-samples (15g) were extracted with acetonitrile, then salted out and partitioned with NaCl and MgSO4. The extract was divided and further cleaned using solid phase extraction (SPE) cartridges containing either graphitized non-porous carbon (pyrethroids) or C18 (degradation products). Sample analysis was via liquid chromatography/tandem mass spectrometry (LC-MS/MS). Considering the mean recoveries each of the 14 analytes in all 13 matrices: 42% of the recoveries were ≥90%, 70% were ≥80%, and 90% were ≥70%. All MDL's were less than 100ng/kg, except 3-PBA (132ng/kg, tomato), MPA (129ng/kg, tomato), and trans-permethrin (141ng/kg, banana peel). We then applied the method to non-spiked samples (subset of 5 for which the MDLs/MQLs had been

  19. Rapid test by liquid chromatography/tandem mass spectrometry to evaluate equine urine reactivity towards 17beta-OH steroids.

    PubMed

    Fidani, Marco; Casagni, Eleonora; Montana, Marco; Pasello, Emanuela; Pecoraro, Chiara; Gambaro, Veniero

    2006-01-01

    Bacteria frequently found in equine urine samples may cause degradation of 17beta-OH steroids. A simple liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed to evaluate the microbiological contamination of equine urine as a marker of poor storage conditions. Norethandrolone was used as the internal standard, and the linearity, sensitivity, precision and accuracy of the method were evaluated. 17beta-OH oxidation was demonstrated for testosterone, nandrolone, trenbolone and boldenone, but did not occur in alpha-epimers such as alpha-boldenone and epitestosterone, demonstrating the stereoselectivity of the reaction. A rapid test was performed by spiking one of the four 17beta-OH steroids in samples of diluted equine urine. The steroids were transformed into their respective ketones in the presence of bacterial activity. The test allows direct injection of diluted samples into the LC/MS system, without the need for prior extraction. Results show that the best method of storage is freezing at -18 degrees C. Urine specimens should be analyzed as soon as possible after thawing. This allows bacterial degradation of equine urine to be arrested temporarily, so that the urine can be used for qualitative or quantitative analysis of 17beta-OH steroids.

  20. Characterization of sphingosine-1-phosphate lyase activity by electrospray ionization-liquid chromatography/tandem mass spectrometry quantitation of (2E)-hexadecenal.

    PubMed

    Berdyshev, Evgeny V; Goya, Jonathan; Gorshkova, Irina; Prestwich, Glenn D; Byun, Hoe-Sup; Bittman, Robert; Natarajan, Viswanathan

    2011-01-01

    Sphingosine-1-phosphate (S1P) is a sphingolipid signaling molecule crucial for cell survival and proliferation. S1P-mediated signaling is largely controlled through its biosynthesis and degradation, and S1P lyase (S1PL) is the only known enzyme that irreversibly degrades sphingoid base-1-phosphates to phosphoethanolamine and the corresponding fatty aldehydes. S1PL-mediated degradation of S1P results in the formation of (2E)-hexadecenal, whereas hexadecanal is the product of dihydrosphingosine-1-phosphate (DHS1P) degradation. Fatty aldehydes can undergo biotransformation to fatty acids and/or alcohols, making them elusive and rendering the task of fatty aldehyde quantitation challenging. We have developed a simple, highly sensitive, and high-throughput protocol for (2E)-hexadecenal quantitation as a semicarbazone derivative by liquid chromatography-electrospray ionization-tandem mass spectrometry. The approach was applied to determining S1PL activity in vitro with the ability to use as low as 0.25μg of microsomal protein per assay. The method is also applicable to the use of total tissue homogenate as the source of S1PL. A correction for (2E)-hexadecenal disappearance due to its biotransformation during enzymatic reaction is required, especially at higher protein concentrations. The method was applied to confirm FTY720 as the inhibitor of S1PL with an IC₅₀ value of 52.4μM. Copyright © 2010 Elsevier Inc. All rights reserved.

  1. Enantioselective analysis of triazole fungicide myclobutanil in cucumber and soil under different application modes by chiral liquid chromatography/tandem mass spectrometry.

    PubMed

    Dong, Fengshou; Cheng, Li; Liu, Xingang; Xu, Jun; Li, Jing; Li, Yuanbo; Kong, Zhiqiang; Jian, Qiu; Zheng, Yongquan

    2012-02-29

    A sensitive and enantioselective method was developed and validated for the determination of myclobutanil enantiomers by chiral liquid chromatography coupled with tandem mass spectrometry. The separation and determination were performed using reversed-phase chromatography on a Chiralcel OD-RH column, with ACN-water (70/30, v/v) as the mobile phase under isocratic conditions at 0.5 mL/min flow rate. The matrix effect, linearity, precision, accuracy, and stability were evaluated. The proposed method then was successfully applied to the study of enantioselective degradation of rac-myclobutanil in cucumber and soil under different application modes. The results showed that the preferential degradation of (+)-myclobutanil resulted in an enrichment of the (-)-myclobutanil residue in plant and soil. Moreover, in cucumber, the stereoselective intensity of myclobutanil under root douche treatment was stronger than that under foliar spraying treatment, whereas in soil, the intensity was exactly opposite. The probable reasons underlying these enantioselective effects were also discussed. This study highlighted the importance of examining the fate of both enantiomers in the greenhouse system for the correct use of chiral pesticides.

  2. Novel rapid liquid chromatography tandem masspectrometry method for vemurafenib and metabolites in human plasma, including metabolite concentrations at steady state.

    PubMed

    Vikingsson, Svante; Strömqvist, Malin; Svedberg, Anna; Hansson, Johan; Höiom, Veronica; Gréen, Henrik

    2016-08-01

    A novel, rapid and sensitive liquid chromatography tandem-mass spectrometry method for quantification of vemurafenib in human plasma, that also for the first time allows for metabolite semi-quantification, was developed and validated to support clinical trials and therapeutic drug monitoring. Vemurafenib was analysed by precipitation with methanol followed by a 1.9 min isocratic liquid chromatography tandem masspectrometry analysis using an Acquity BEH C18 column with methanol and formic acid using isotope labelled internal standards. Analytes were detected in multireaction monitoring mode on a Xevo TQ. Semi-quantification of vemurafenib metabolites was performed using the same analytical system and sample preparation with gradient elution. The vemurafenib method was successfully validated in the range 0.5-100 μg/mL according to international guidelines. The metabolite method was partially validated owing to the lack of commercially available reference materials. For the first time concentration levels at steady state for melanoma patients treated with vemurafenib is presented. The low abundance of vemurafenib metabolites suggests that they lack clinical significance. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. A new liquid chromatography-tandem mass spectrometry method using atmospheric pressure photo ionization for the simultaneous determination of azaarenes and azaarones in Dutch river sediments.

    PubMed

    Brulik, Jan; Simek, Zdenek; de Voogt, Pim

    2013-06-14

    A new method for the analysis of azaarenes and their degradation products (azaarones) was developed, optimized and validated using liquid chromatography coupled with atmospheric pressure photo ionization tandem mass spectrometric detection (LC-APPI/MS/MS). Seventeen compounds including 4 PAHs (naphthalene, anthracene, phenanthrene, benz[a]anthracene), 7 azaarenes (quinoline, acridine, phenanthridine, 5,6-benzoquinoline and 7,8-benzoquinoline, benzo[a]acridine, benzo[c]acridine), and 6 azaarones (2-OH-quinoline, 4-OH-quinoline, 5-OH-quinoline, 6-OH-quinoline, 9(10H)-acridone, 6(5H)phenanthridinone) were analyzed in sediment samples from Dutch rivers. All compounds were analyzed simultaneously in multi reaction monitoring (MRM) mode. Soxhlet extraction was used for the extraction of analytes from sediments. The limits of quantification of azaarenes and azaarones varied from 0.21 to 1.12μg/l and from 0.23 to 1.58μg/l, respectively. The limits of quantification for PAHs varied from 32 to 769μg/l. Matrix-independent recoveries of sediment samples were in the range 85-110%; matrix-dependent recoveries were in the range 73-148%, respectively. The method was tested on real sediment samples and the results were compared with a previous study in which GC/MS/MS was used for the simultaneous measurement of azaarenes and azaarones. 4-, 5- and 6-OH-quinolines and naphthalene, anthracene and phenanthrene were not present or below detection limits in some samples. All other analytes were present in samples in the concentration range 0.2-1200ng/g (dw). To our knowledge, this is the first report showing the possibility of measurement non-polar polyaromatic hydrocarbons together with polar azaarenes and their degradation products azaarones simultaneously with sufficient sensitivity and accuracy using LC/MS/MS. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Electron-irradiated two-terminal, monolithic InP/Ga0.47In0.53As tandem solar cells and annealing of radiation damage

    NASA Technical Reports Server (NTRS)

    Cotal, H. L.; Walters, Robert J.; Summers, Geoffrey P.; Messenger, Scott R.

    1994-01-01

    Radiation damage results from two-terminal monolithic InP/Ga(0.47)In(0.53)As tandem solar cells subject to 1 MeV electron irradiation are presented. Efficiencies greater than 22 percent have been measured by the National Renewable Energy Laboratory from 2x2 sq cm cells at 1 sun, AMO (25 C). The short circuit current density, open circuit voltage and fill factor are found to tolerate the same amount of radiation at low fluences. At high fluence levels, slight differences are observed. Decreasing the base amount of radiation at the Ga(0.47)In(0.53)As bottomcell improved the radiation resistance of J(sub sc) dramatically. This is turn, extended the series current flow through the subcell substantially up to a fluence of 3x10(exp 15) cm(exp -2) compared to 3x10(exp 14) cm(exp -2), as observed previously. The degradation of the maximum power output form tandem device is comparable to that from shallow homojunction (SHJ) InP solar cells, and the mechanism responsible for such degradation is explained in terms of the radiation response of the component cells. Annealing studies revealed that the recovery of the tandem cell response is dictated by the annealing characteristics exhibited by SHJ InP solar cells.

  5. Stabilization of perfect and imperfect tandem repeats by single-strand DNA exonucleases

    PubMed Central

    Feschenko, Vladimir V.; Rajman, Luis A.; Lovett, Susan T.

    2003-01-01

    Rearrangements between tandemly repeated DNA sequences are a common source of genetic instability. Such rearrangements underlie several human genetic diseases. In many organisms, the mismatch-repair (MMR) system functions to stabilize repeats when the repeat unit is short or when sequence imperfections are present between the repeats. We show here that the action of single-stranded DNA (ssDNA) exonucleases plays an additional, important role in stabilizing tandem repeats, independent of their role in MMR. For perfect repeats of ≈100 bp in Escherichia coli that are not susceptible to MMR, exonuclease (Exo)-I, ExoX, and RecJ exonuclease redundantly inhibit deletion. Our data suggest that >90% of potential deletion events are avoided by the combined action of these three exonucleases. Imperfect tandem repeats, less prone to rearrangements, are stabilized by both the MMR-pathway and ssDNA-specific exonucleases. For 100-bp repeats containing four mispairs, ExoI alone aborts most deletion events, even in the presence of a functional MMR system. By genetic analysis, we show that the inhibitory effect of ssDNA exonucleases on deletion formation is independent of the MutS and UvrD proteins. Exonuclease degradation of DNA displaced during the deletion process may abort slipped misalignment. Exonuclease action is therefore a significant force in genetic stabilization of many forms of repetitive DNA. PMID:12538867

  6. Protein Sequencing with Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Ziady, Assem G.; Kinter, Michael

    The recent introduction of electrospray ionization techniques that are suitable for peptides and whole proteins has allowed for the design of mass spectrometric protocols that provide accurate sequence information for proteins. The advantages gained by these approaches over traditional Edman Degradation sequencing include faster analysis and femtomole, sometimes attomole, sensitivity. The ability to efficiently identify proteins has allowed investigators to conduct studies on their differential expression or modification in response to various treatments or disease states. In this chapter, we discuss the use of electrospray tandem mass spectrometry, a technique whereby protein-derived peptides are subjected to fragmentation in the gas phase, revealing sequence information for the protein. This powerful technique has been instrumental for the study of proteins and markers associated with various disorders, including heart disease, cancer, and cystic fibrosis. We use the study of protein expression in cystic fibrosis as an example.

  7. Detecting long tandem duplications in genomic sequences.

    PubMed

    Audemard, Eric; Schiex, Thomas; Faraut, Thomas

    2012-05-08

    Detecting duplication segments within completely sequenced genomes provides valuable information to address genome evolution and in particular the important question of the emergence of novel functions. The usual approach to gene duplication detection, based on all-pairs protein gene comparisons, provides only a restricted view of duplication. In this paper, we introduce ReD Tandem, a software using a flow based chaining algorithm targeted at detecting tandem duplication arrays of moderate to longer length regions, with possibly locally weak similarities, directly at the DNA level. On the A. thaliana genome, using a reference set of tandem duplicated genes built using TAIR,(a) we show that ReD Tandem is able to predict a large fraction of recently duplicated genes (dS  <  1) and that it is also able to predict tandem duplications involving non coding elements such as pseudo-genes or RNA genes. ReD Tandem allows to identify large tandem duplications without any annotation, leading to agnostic identification of tandem duplications. This approach nicely complements the usual protein gene based which ignores duplications involving non coding regions. It is however inherently restricted to relatively recent duplications. By recovering otherwise ignored events, ReD Tandem gives a more comprehensive view of existing evolutionary processes and may also allow to improve existing annotations.

  8. Effect of actinobacteria agent inoculation methods on cellulose degradation during composting based on redundancy analysis.

    PubMed

    Zhao, Yue; Lu, Qian; Wei, Yuquan; Cui, Hongyang; Zhang, Xu; Wang, Xueqin; Shan, Si; Wei, Zimin

    2016-11-01

    In this study, actinobacteria agent including Streptomyces sp. and Micromonospora sp. were inoculated during chicken manure composting by different inoculation methods. The effect of different treatments on cellulose degradation and the relationship between inoculants and indigenous actinobacteria were investigated during composting. The results showed that inoculation in different stages of composting all improved the actinobacteria community diversity particularly in the cooling stage of composting (M3). Moreover, inoculation could distinctly accelerate the degradation of organic matters (OM) especially celluloses. Redundancy analysis indicated that the correlation between indigenous actinobacteria and degradation of OM and cellulose were regulated by inoculants and there were significant differences between different inoculation methods. Furthermore, synergy between indigenous actinobacteria and inoculants for degradation of OM and cellulose in M3 was better than other treatments. Conclusively, we suggested an inoculation method to regulate the indigenous actinobacteria based on the relationship between inoculants and indigenous actinobacteria and degradation content. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. A hybrid degradation tendency measurement method for mechanical equipment based on moving window and Grey-Markov model

    NASA Astrophysics Data System (ADS)

    Jiang, Wei; Zhou, Jianzhong; Zheng, Yang; Liu, Han

    2017-11-01

    Accurate degradation tendency measurement is vital for the secure operation of mechanical equipment. However, the existing techniques and methodologies for degradation measurement still face challenges, such as lack of appropriate degradation indicator, insufficient accuracy, and poor capability to track the data fluctuation. To solve these problems, a hybrid degradation tendency measurement method for mechanical equipment based on a moving window and Grey-Markov model is proposed in this paper. In the proposed method, a 1D normalized degradation index based on multi-feature fusion is designed to assess the extent of degradation. Subsequently, the moving window algorithm is integrated with the Grey-Markov model for the dynamic update of the model. Two key parameters, namely the step size and the number of states, contribute to the adaptive modeling and multi-step prediction. Finally, three types of combination prediction models are established to measure the degradation trend of equipment. The effectiveness of the proposed method is validated with a case study on the health monitoring of turbine engines. Experimental results show that the proposed method has better performance, in terms of both measuring accuracy and data fluctuation tracing, in comparison with other conventional methods.

  10. An accurate proteomic quantification method: fluorescence labeling absolute quantification (FLAQ) using multidimensional liquid chromatography and tandem mass spectrometry.

    PubMed

    Liu, Junyan; Liu, Yang; Gao, Mingxia; Zhang, Xiangmin

    2012-08-01

    A facile proteomic quantification method, fluorescent labeling absolute quantification (FLAQ), was developed. Instead of using MS for quantification, the FLAQ method is a chromatography-based quantification in combination with MS for identification. Multidimensional liquid chromatography (MDLC) with laser-induced fluorescence (LIF) detection with high accuracy and tandem MS system were employed for FLAQ. Several requirements should be met for fluorescent labeling in MS identification: Labeling completeness, minimum side-reactions, simple MS spectra, and no extra tandem MS fragmentations for structure elucidations. A fluorescence dye, 5-iodoacetamidofluorescein, was finally chosen to label proteins on all cysteine residues. The fluorescent dye was compatible with the process of the trypsin digestion and MALDI MS identification. Quantitative labeling was achieved with optimization of reacting conditions. A synthesized peptide and model proteins, BSA (35 cysteines), OVA (five cysteines), were used for verifying the completeness of labeling. Proteins were separated through MDLC and quantified based on fluorescent intensities, followed by MS identification. High accuracy (RSD% < 1.58) and wide linearity of quantification (1-10(5) ) were achieved by LIF detection. The limit of quantitation for the model protein was as low as 0.34 amol. Parts of proteins in human liver proteome were quantified and demonstrated using FLAQ. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Sorption and degradation of neonicotinoid insecticides in tropical soils.

    PubMed

    Dankyi, Enock; Gordon, Chris; Carboo, Derick; Apalangya, Vitus A; Fomsgaard, Inge S

    2018-05-22

    Neonicotinoids are the most widely applied class of insecticides in cocoa farming in Ghana. Despite the intensive application of these insecticides, knowledge of their fate in the Ghanaian and sub-Saharan African environment remains low. This study examined the behavior of neonicotinoids in soils from cocoa plantations in Ghana by estimating their sorption and degradation using established kinetic models and isotherms. Studies of sorption were conducted using the batch equilibrium method on imidacloprid, thiamethoxam, clothianidin, acetamiprid and thiacloprid, while degradation of imidacloprid, thiamethoxam and their respective deuterated counterparts was studied using models proposed by the European forum for coordination of pesticide fate and their use (FOCUS). Analytes were extracted using the quick, easy, cheap, effective, rugged and safe (QuEChERS) procedure and quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Average recoveries were high (≥ 85%) for all analytes. The findings from the study suggest that neonicotinoid insecticides may be persistent in the soils studied based on estimated half-lives > 150 days. The study also revealed generally low-sorption coefficients for neonicotinoids in soils, largely influenced by soil organic carbon.

  12. Validated stability-indicating spectrophotometric methods for the determination of Silodosin in the presence of its degradation products.

    PubMed

    Boltia, Shereen A; Abdelkawy, Mohammed; Mohammed, Taghreed A; Mostafa, Nahla N

    2018-09-05

    Five simple, rapid, accurate, and precise spectrophotometric methods are developed for the determination of Silodosin (SLD) in the presence of its acid induced and oxidative induced degradation products. Method A is based on dual wavelength (DW) method; two wavelengths are selected at which the absorbance of the oxidative induced degradation product is the same, so wavelengths 352 and 377 nm are used to determine SLD in the presence of its oxidative induced degradation product. Method B depends on induced dual wavelength theory (IDW), which is based on selecting two wavelengths on the zero-order spectrum of SLD where the difference in absorbance between them for the spectrum of acid induced degradation products is not equal to zero so through multiplying by the equality factor, the absorption difference is made to be zero for the acid induced degradation product while it is still significant for SLD. Method C is first derivative ( 1 D) spectrophotometry of SLD and its degradation products. Peak amplitudes are measured at 317 and 357 nm. Method D is ratio difference spectrophotometry (RD) where the drug is determined by the difference in amplitude between two selected wavelengths, at 350 and 277 nm for the ratio spectrum of SLD and its acid induced degradation products while for the ratio spectrum of SLD and its oxidative induced degradation products the difference in amplitude is measured at 345 and 292 nm. Method E depends on measuring peak amplitudes of the first derivative of the ratio ( 1 DD) where peak amplitudes are measured at 330 nm in the presence of the acid induced degradation product and measured by peak to peak technique at 326 and 369 nm in the presence of the oxidative induced degradation product. The proposed methods are validated according to ICH recommendations. The calibration curves for all the proposed methods are linear over a concentration range of 5-70 μg/mL. The selectivity of the proposed methods was tested using different

  13. Diclofenac in municipal wastewater treatment plant: quantification using laser diode thermal desorption--atmospheric pressure chemical ionization--tandem mass spectrometry approach in comparison with an established liquid chromatography-electrospray ionization-tandem mass spectrometry method.

    PubMed

    Lonappan, Linson; Pulicharla, Rama; Rouissi, Tarek; Brar, Satinder K; Verma, Mausam; Surampalli, Rao Y; Valero, José R

    2016-02-12

    Diclofenac (DCF), a prevalent non-steroidal anti-inflammatory drug (NSAID) is often detected in wastewater and surface water. Analysis of the pharmaceuticals in complex matrices is often laden with challenges. In this study a reliable, rapid and sensitive method based on laser diode thermal desorption/atmospheric pressure chemical ionization (LDTD/APCI) coupled with tandem mass spectrometry (MS/MS) has been developed for the quantification of DCF in wastewater and wastewater sludge. An established conventional LC-ESI-MS/MS (liquid chromatography-electrospray ionization-tandem mass spectrometry) method was compared with LDTD-APCI-MS/MS approach. The newly developed LDTD-APCI-MS/MS method reduced the analysis time to 12s in lieu of 12 min for LC-ESI-MS/MS method. The method detection limits for LDTD-APCI-MS/MS method were found to be 270 ng L(-1) (LOD) and 1000 ng L(-1) (LOQ). Furthermore, two extraction procedures, ultrasonic assisted extraction (USE) and accelerated solvent extraction (ASE) for the extraction of DCF from wastewater sludge were compared and ASE with 95.6 ± 7% recovery was effective over USE with 86 ± 4% recovery. The fate and partitioning of DCF in wastewater (WW) and wastewater sludge (WWS) in wastewater treatment plant was also monitored at various stages of treatment in Quebec Urban community wastewater treatment plant. DCF exhibited affinity towards WW than WWS with a presence about 60% of DCF in WW in contrary with theoretical prediction (LogKow=4.51). Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Targeted polypeptide degradation

    DOEpatents

    Church, George M [Brookline, MA; Janse, Daniel M [Brookline, MA

    2008-05-13

    This invention pertains to compositions, methods, cells and organisms useful for selectively localizing polypeptides to the proteasome for degradation. Therapeutic methods and pharmaceutical compositions for treating disorders associated with the expression and/or activity of a polypeptide by targeting these polypeptides for degradation, as well as methods for targeting therapeutic polypeptides for degradation and/or activating therapeutic polypeptides by degradation are provided. The invention provides methods for identifying compounds that mediate proteasome localization and/or polypeptide degradation. The invention also provides research tools for the study of protein function.

  15. Comparative analysis of tandem repeats from hundreds of species reveals unique insights into centromere evolution.

    PubMed

    Melters, Daniël P; Bradnam, Keith R; Young, Hugh A; Telis, Natalie; May, Michael R; Ruby, J Graham; Sebra, Robert; Peluso, Paul; Eid, John; Rank, David; Garcia, José Fernando; DeRisi, Joseph L; Smith, Timothy; Tobias, Christian; Ross-Ibarra, Jeffrey; Korf, Ian; Chan, Simon W L

    2013-01-30

    Centromeres are essential for chromosome segregation, yet their DNA sequences evolve rapidly. In most animals and plants that have been studied, centromeres contain megabase-scale arrays of tandem repeats. Despite their importance, very little is known about the degree to which centromere tandem repeats share common properties between different species across different phyla. We used bioinformatic methods to identify high-copy tandem repeats from 282 species using publicly available genomic sequence and our own data. Our methods are compatible with all current sequencing technologies. Long Pacific Biosciences sequence reads allowed us to find tandem repeat monomers up to 1,419 bp. We assumed that the most abundant tandem repeat is the centromere DNA, which was true for most species whose centromeres have been previously characterized, suggesting this is a general property of genomes. High-copy centromere tandem repeats were found in almost all animal and plant genomes, but repeat monomers were highly variable in sequence composition and length. Furthermore, phylogenetic analysis of sequence homology showed little evidence of sequence conservation beyond approximately 50 million years of divergence. We find that despite an overall lack of sequence conservation, centromere tandem repeats from diverse species showed similar modes of evolution. While centromere position in most eukaryotes is epigenetically determined, our results indicate that tandem repeats are highly prevalent at centromeres of both animal and plant genomes. This suggests a functional role for such repeats, perhaps in promoting concerted evolution of centromere DNA across chromosomes.

  16. Comparative analysis of tandem repeats from hundreds of species reveals unique insights into centromere evolution

    PubMed Central

    2013-01-01

    Background Centromeres are essential for chromosome segregation, yet their DNA sequences evolve rapidly. In most animals and plants that have been studied, centromeres contain megabase-scale arrays of tandem repeats. Despite their importance, very little is known about the degree to which centromere tandem repeats share common properties between different species across different phyla. We used bioinformatic methods to identify high-copy tandem repeats from 282 species using publicly available genomic sequence and our own data. Results Our methods are compatible with all current sequencing technologies. Long Pacific Biosciences sequence reads allowed us to find tandem repeat monomers up to 1,419 bp. We assumed that the most abundant tandem repeat is the centromere DNA, which was true for most species whose centromeres have been previously characterized, suggesting this is a general property of genomes. High-copy centromere tandem repeats were found in almost all animal and plant genomes, but repeat monomers were highly variable in sequence composition and length. Furthermore, phylogenetic analysis of sequence homology showed little evidence of sequence conservation beyond approximately 50 million years of divergence. We find that despite an overall lack of sequence conservation, centromere tandem repeats from diverse species showed similar modes of evolution. Conclusions While centromere position in most eukaryotes is epigenetically determined, our results indicate that tandem repeats are highly prevalent at centromeres of both animal and plant genomes. This suggests a functional role for such repeats, perhaps in promoting concerted evolution of centromere DNA across chromosomes. PMID:23363705

  17. Degradation product characterization of therapeutic oligonucleotides using liquid chromatography mass spectrometry.

    PubMed

    Elzahar, N M; Magdy, N; El-Kosasy, Amira M; Bartlett, Michael G

    2018-05-01

    Synthetic antisense phosphorothioate oligonucleotides (PS) have undergone rapid development as novel therapeutic agents. The increasing significance of this class of drugs requires significant investment in the development of quality control methods. The determination of the many degradation pathways of such complex molecules presents a significant challenge. However, an understanding of the potential impurities that may arise is necessary to continue to advance these powerful new therapeutics. In this study, four different antisense oligonucleotides representing several generations of oligonucleotide therapeutic agents were evaluated under various stress conditions (pH, thermal, and oxidative stress) using ion-pairing reversed-phase liquid chromatography tandem mass spectrometry (IP-RPLC-MS/MS) to provide in-depth characterization and identification of the degradation products. The oligonucleotide samples were stressed under different pH values at 45 and 90 °C. The main degradation products were observed to be losses of nucleotide moieties from the 3'- and 5'-terminus, depurination, formation of terminal phosphorothioates, and production of ribose, ribophosphorothioates (Rp), and phosphoribophosphorothioates (pRp). Moreover, the effects of different concentrations of hydrogen peroxide were studied resulting in primarily extensive desulfurization and subsequent oxidation of the phosphorothioate linkage to produce the corresponding phosphodiester. The reaction kinetics for the degradation of the oligonucleotides under the different stress conditions were studied and were found to follow pseudo-first-order kinetics. Differences in rates exist even for oligonucleotides of similar length but consisting of different sequences. Graphical abstract Identification of degradation products across several generations of oligonucleotide therapeutics using LC-MS.

  18. Degradation Kinetics Study of Alogliptin Benzoate in Alkaline Medium by Validated Stability-Indicating HPTLC Method.

    PubMed

    Bodiwala, Kunjan Bharatkumar; Shah, Shailesh; Thakor, Jeenal; Marolia, Bhavin; Prajapati, Pintu

    2016-11-01

    A rapid, sensitive, and stability-indicating high-performance thin-layer chromatographic method was developed and validated to study degradation kinetics of Alogliptin benzoate (ALG) in an alkaline medium. ALG was degraded under acidic, alkaline, oxidative, and thermal stress conditions. The degraded samples were chromatographed on silica gel 60F254-TLC plates, developed using a quaternary-solvent system (chloroform-methanol-ethyl acetate-triethyl amine, 9+1+1+0.5, v/v/v/v), and scanned at 278 nm. The developed method was validated per International Conference on Harmonization guidelines using validation parameters such as specificity, linearity and range, precision, accuracy, LOD, and LOQ. The linearity range for ALG was 100-500 ng/band (correlation coefficient = 0.9997) with an average recovery of 99.47%. The LOD and LOQ for ALG were 9.8 and 32.7 ng/band, respectively. The developed method was successfully applied for the quantitative estimation of ALG in its synthetic mixture with common excipients. Degradation kinetics of ALG in an alkaline medium was studied by degrading it under three different temperatures and three different concentrations of alkali. Degradation of ALG in the alkaline medium was found to follow first-order kinetics. Contour plots have been generated to predict degradation rate constant, half-life, and shelf life of ALG in various combinations of temperature and concentration of alkali using Design Expert software.

  19. Stability-indicating UPLC method for determining related substances and degradants in dronedarone.

    PubMed

    Pydimarry, Surya Prakash Rao; Cholleti, Vijay Kumar; Vangala, Ranga Reddy

    2014-08-01

    A simple, sensitive and reproducible method was developed on ultra-performance liquid chromatography coupled with photodiode array detection for the quantitative determination of dronedarone hydrochloride (DRO) in drug substance and pharmaceutical dosage forms. The method is applicable for the quantification of related substances and assays of drug substances. Chromatographic separation was achieved on Acquity UPLC BEH C8 100 mm, 2.1 mm and 1.7 µm columns, using gradient elution within a short run time of 10.0 min. The eluted compounds were monitored at 288 nm, the flow rate was 0.5 mL/min and the column oven temperature was maintained at 40°C. The resolution of DRO and 11 impurities (potentials and by-products) was greater than 2.0 for all pairs of components. The high correlation coefficient value (>0.9995) indicates the clear correlations between the concentrations of investigated compound and their peak areas within the test ranges. The repeatability and intermediate precision, expressed by the relative standard deviation, were less than 2.5%. The accuracy and validity of the method were further ascertained by performing recovery studies via a spike method. The accuracy of the method, expressed as relative error, was satisfactory. No interference was observed from concomitant substances normally added to the tablets. DRO was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. DRO was found to degrade significantly in acid and base stress conditions and to remain stable in thermal, photolytic degradation, oxidative and hydrolytic conditions. The degradation products were well resolved from primary peak and its impurities, proving that the method is stability indicating. The developed method was validated as per International Conference on Harmonization guidelines with respect to specificity, limit of detection, limit of quantification, linearity, accuracy, precision, solution stability and robustness

  20. A Derivative Method with Free Radical Oxidation to Predict Resveratrol Metabolites by Tandem Mass Spectrometry

    PubMed Central

    Liu, Wangta; Shiue, Yow-Ling; Lin, Yi-Reng; Lin, Hugo You-Hsien; Liang, Shih-Shin

    2015-01-01

    In this study, we demonstrated an oxidative method with free radical to generate 3,5,4′-trihydroxy-trans-stilbene (trans-resveratrol) metabolites and detect sequentially by an autosampler coupling with liquid chromatography electrospray ionization tandem mass spectrometer (LC-ESI–MS/MS). In this oxidative method, the free radical initiator, ammonium persulfate (APS), was placed in a sample bottle containing resveratrol to produce oxidative derivatives, and the reaction progress was tracked by autosampler sequencing. Resveratrol, a natural product with purported cancer preventative qualities, produces metabolites including dihydroresveratrol, 3,4′-dihydroxy-trans-stilbene, lunularin, resveratrol monosulfate, and dihydroresveratrol monosulfate by free radical oxidation. Using APS free radical, the concentrations of resveratrol derivatives differ as a function of time. Besides simple, convenient and time- and labor saving, the advantages of free radical oxidative method of its in situ generation of oxidative derivatives followed by LC-ESI–MS/MS can be utilized to evaluate different metabolites in various conditions. PMID:27594817

  1. A Derivative Method with Free Radical Oxidation to Predict Resveratrol Metabolites by Tandem Mass Spectrometry.

    PubMed

    Liu, Wangta; Shiue, Yow-Ling; Lin, Yi-Reng; Lin, Hugo You-Hsien; Liang, Shih-Shin

    2015-10-01

    In this study, we demonstrated an oxidative method with free radical to generate 3,5,4'-trihydroxy- trans -stilbene ( trans -resveratrol) metabolites and detect sequentially by an autosampler coupling with liquid chromatography electrospray ionization tandem mass spectrometer (LC-ESI-MS/MS). In this oxidative method, the free radical initiator, ammonium persulfate (APS), was placed in a sample bottle containing resveratrol to produce oxidative derivatives, and the reaction progress was tracked by autosampler sequencing. Resveratrol, a natural product with purported cancer preventative qualities, produces metabolites including dihydroresveratrol, 3,4'-dihydroxy- trans -stilbene, lunularin, resveratrol monosulfate, and dihydroresveratrol monosulfate by free radical oxidation. Using APS free radical, the concentrations of resveratrol derivatives differ as a function of time. Besides simple, convenient and time- and labor saving, the advantages of free radical oxidative method of its in situ generation of oxidative derivatives followed by LC-ESI-MS/MS can be utilized to evaluate different metabolites in various conditions.

  2. Research study on high energy radiation effect and environment solar cell degradation methods

    NASA Technical Reports Server (NTRS)

    Horne, W. E.; Wilkinson, M. C.

    1974-01-01

    The most detailed and comprehensively verified analytical model was used to evaluate the effects of simplifying assumptions on the accuracy of predictions made by the external damage coefficient method. It was found that the most serious discrepancies were present in heavily damaged cells, particularly proton damaged cells, in which a gradient in damage across the cell existed. In general, it was found that the current damage coefficient method tends to underestimate damage at high fluences. An exception to this rule was thick cover-slipped cells experiencing heavy degradation due to omnidirectional electrons. In such cases, the damage coefficient method overestimates the damage. Comparisons of degradation predictions made by the two methods and measured flight data confirmed the above findings.

  3. Simplified MPN method for enumeration of soil naphthalene degraders using gaseous substrate.

    PubMed

    Wallenius, Kaisa; Lappi, Kaisa; Mikkonen, Anu; Wickström, Annika; Vaalama, Anu; Lehtinen, Taru; Suominen, Leena

    2012-02-01

    We describe a simplified microplate most-probable-number (MPN) procedure to quantify the bacterial naphthalene degrader population in soil samples. In this method, the sole substrate naphthalene is dosed passively via gaseous phase to liquid medium and the detection of growth is based on the automated measurement of turbidity using an absorbance reader. The performance of the new method was evaluated by comparison with a recently introduced method in which the substrate is dissolved in inert silicone oil and added individually to each well, and the results are scored visually using a respiration indicator dye. Oil-contaminated industrial soil showed slightly but significantly higher MPN estimate with our method than with the reference method. This suggests that gaseous naphthalene was dissolved in an adequate concentration to support the growth of naphthalene degraders without being too toxic. The dosing of substrate via gaseous phase notably reduced the work load and risk of contamination. The result scoring by absorbance measurement was objective and more reliable than measurement with indicator dye, and it also enabled further analysis of cultures. Several bacterial genera were identified by cloning and sequencing of 16S rRNA genes from the MPN wells incubated in the presence of gaseous naphthalene. In addition, the applicability of the simplified MPN method was demonstrated by a significant positive correlation between the level of oil contamination and the number of naphthalene degraders detected in soil.

  4. Monolithic Perovskite Silicon Tandem Solar Cells with Advanced Optics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldschmidt, Jan C.; Bett, Alexander J.; Bivour, Martin

    2016-11-14

    For high efficiency monolithic perovskite silicon tandem solar cells, we develop low-temperature processes for the perovskite top cell, rear-side light trapping, optimized perovskite growth, transparent contacts and adapted characterization methods.

  5. Short Tandem Repeat DNA Internet Database

    National Institute of Standards and Technology Data Gateway

    SRD 130 Short Tandem Repeat DNA Internet Database (Web, free access)   Short Tandem Repeat DNA Internet Database is intended to benefit research and application of short tandem repeat DNA markers for human identity testing. Facts and sequence information on each STR system, population data, commonly used multiplex STR systems, PCR primers and conditions, and a review of various technologies for analysis of STR alleles have been included.

  6. Degradation of learned skills: Effectiveness of practice methods on visual approach and landing skill retention

    NASA Technical Reports Server (NTRS)

    Sitterley, T. E.; Zaitzeff, L. P.; Berge, W. A.

    1972-01-01

    Flight control and procedural task skill degradation, and the effectiveness of retraining methods were evaluated for a simulated space vehicle approach and landing under instrument and visual flight conditions. Fifteen experienced pilots were trained and then tested after 4 months either without the benefits of practice or with static rehearsal, dynamic rehearsal or with dynamic warmup practice. Performance on both the flight control and procedure tasks degraded significantly after 4 months. The rehearsal methods effectively countered procedure task skill degradation, while dynamic rehearsal or a combination of static rehearsal and dynamic warmup practice was required for the flight control tasks. The quality of the retraining methods appeared to be primarily dependent on the efficiency of visual cue reinforcement.

  7. Software for peak finding and elemental composition assignment for glycosaminoglycan tandem mass spectra.

    PubMed

    Hogan, John D; Klein, Joshua A; Wu, Jiandong; Chopra, Pradeep; Boons, Geert-Jan; Carvalho, Luis; Lin, Cheng; Zaia, Joseph

    2018-04-03

    Glycosaminoglycans (GAGs) covalently linked to proteoglycans (PGs) are characterized by repeating disaccharide units and variable sulfation patterns along the chain. GAG length and sulfation patterns impact disease etiology, cellular signaling, and structural support for cells. We and others have demonstrated the usefulness of tandem mass spectrometry (MS2) for assigning the structures of GAG saccharides; however, manual interpretation of tandem mass spectra is time-consuming, so computational methods must be employed. In the proteomics domain, the identification of monoisotopic peaks and charge states relies on algorithms that use averagine, or the average building block of the compound class being analyzed. While these methods perform well for protein and peptide spectra, they perform poorly on GAG tandem mass spectra, due to the fact that a single average building block does not characterize the variable sulfation of GAG disaccharide units. In addition, it is necessary to assign product ion isotope patterns in order to interpret the tandem mass spectra of GAG saccharides. To address these problems, we developed GAGfinder, the first tandem mass spectrum peak finding algorithm developed specifically for GAGs. We define peak finding as assigning experimental isotopic peaks directly to a given product ion composition, as opposed to deconvolution or peak picking, which are terms more accurately describing the existing methods previously mentioned. GAGfinder is a targeted, brute force approach to spectrum analysis that utilizes precursor composition information to generate all theoretical fragments. GAGfinder also performs peak isotope composition annotation, which is typically a subsequent step for averagine-based methods. Data are available via ProteomeXchange with identifier PXD009101. Published under license by The American Society for Biochemistry and Molecular Biology, Inc.

  8. Method for determination of methyl tert-butyl ether and its degradation products in water

    USGS Publications Warehouse

    Church, C.D.; Isabelle, L.M.; Pankow, J.F.; Rose, D.L.; Tratnyek, P.G.

    1997-01-01

    An analytical method is described that can detect the major alkyl ether compounds that are used as gasoline oxygenates (methyl tert-butyl ether, MTBE; ethyl tert-butyl ether, ETBE; and tert-amyl methyl ether, TAME) and their most characteristic degradation products (tert-butyl alcohol, TBA; tert-butyl formate, TBF; and tert-amyl alcohol, TAA) in water at sub-ppb concentrations. The new method involves gas chromatography (GC) with direct aqueous injection (DAI) onto a polar column via a splitless injector, coupled with detection by mass spectrometry (MS). DAI-GC/MS gives excellent agreement with conventional purge-and-trap methods for MTBE over a wide range of environmentally relevant concentrations. The new method can also give simultaneous identification of polar compounds that might occur as degradation products of gasoline oxygenates, such as TBA, TBF, TAA, methyl acetate, and acetone. When the method was applied to effluent from a column microcosm prepared with core material from an urban site in New Jersey, conversion of MTBE to TBA was observed after a lag period of 35 days. However, to date, analyses of water samples from six field sites using the DAI-GC/MS method have not produced evidence for the expected products of in situ degradation of MTBE.An analytical method is described that can detect the major alkyl ether compounds that are used as gasoline oxygenates (methyl tert-butyl ether, MTBE; ethyl tert-butyl ether, ETBE; and tert-amyl methyl ether, TAME) and their most characteristic degradation products (tert-butyl alcohol, TBA; tert-butyl formate, TBF; and tert-amyl alcohol, TAA) in water at sub-ppb concentrations. The new method involves gas chromatography (GC) with direct aqueous injection (DAI) onto a polar column via a splitless injector, coupled with detection by mass spectrometry (MS). DAI-GC/MS gives excellent agreement with conventional purge-and-trap methods for MTBE over a wide range of environmentally relevant concentrations. The new method

  9. Methods for the Detection of Autophagy in Mammalian Cells

    PubMed Central

    Zhang, Ziyan; Singh, Rajat; Aschner, Michael

    2016-01-01

    Macroautophagy (hereafter referred to as autophagy) is a degradation pathway that delivers cytoplasmic materials to lysosomes via double-membraned vesicles designated autophagosomes. Cytoplasmic constituents are sequestered into autophagosomes, which subsequently fuse with lysosomes, where the cargo is degraded. Autophagy is a crucial mechanism involved in many aspects of cell function, including cellular metabolism and energy balance; and alterations in autophagy have been linked to various human pathological processes. Thus, methods that accurately measure autophagic activity are necessary. In this unit, we introduce several approaches to analyze autophagy in mammalian cells, including immunoblotting analysis of LC3 and p62, detection of autophagosome formation by fluorescence microscopy, and monitoring autophagosome maturation by tandem mRFP-GFP fluorescence microscopy. Overall, we recommend a combined use of multiple methods to accurately assess the autophagic activity in any given biological setting. PMID:27479363

  10. Degradation of the Alternaria mycotoxins alternariol, alternariol monomethyl ether, and altenuene upon bread baking.

    PubMed

    Siegel, David; Feist, Michael; Proske, Matthias; Koch, Matthias; Nehls, Irene

    2010-09-08

    The stability of the Alternaria mycotoxins alternariol, alternariol monomethyl ether, and altenuene upon bread baking was investigated by model experiments using a spiked wholemeal wheat flour matrix. For alternariol and alternariol monomethyl ether, but not for altenuene, degradation products, formed through a sequence of hydrolysis and decarboxylation, could be identified in pilot studies. The simultaneous quantification of alternariol, alternariol monomethyl ether, altenuene, and the degradation products was achieved by a newly developed high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) multimethod. The obtained quantitative data indicate that the Alternaria mycotoxins are barely degraded during wet baking, while significant degradation occurs upon dry baking, with the stability decreasing in the order alternariol monomethyl ether>alternariol>altenuene. The novel degradation products could be detected after the wet baking of flour spiked with alternariol and in a sample survey of 24 commercial cereal based baking products.

  11. Biocarrier composition for and method of degrading pollutants

    DOEpatents

    Fliermans, C.B.

    1994-01-01

    The present invention relates to biocarrier compositions that attract and bond pollutant-degrading antigens that will degrade the pollutants. Biocarriers are known generally as a variety of inert or semi-inert compounds or structures having the ability to sequester (attract), hold and biomagnify (enhance) specific microorganisms within their structure. Glass or polystyrene beads are the most well known biocarriers. The biocarrier, which is preferably in the form of glass microspheres, is coated with an antibody or group of antibodies that attract and react specifically with certain pollutant-degrading antigens. The antibody, once bonded to the biocarrier, is used by the composition to attract and bond those pollutant-degrading antigens. Each antibody is specific for an antigen that is specific for a given pollutant. The resulting composition is subsequently exposed to an environment contaminated with pollutants for degradation. In the preferred use, the degrading composition is formed and then injected directly into or near a plume or source of contamination.

  12. Different Spectrophotometric Methods for Simultaneous Determination of Trelagliptin and Its Acid Degradation Product.

    PubMed

    Mowaka, Shereen; Ayoub, Bassam M; Hassan, Mostafa A; Zaghary, Wafaa A

    2018-01-01

    New spectrophotometric and chemometric methods were carried out for the simultaneous assay of trelagliptin (TRG) and its acid degradation product (TAD) and applied successfully as a stability indicating assay to recently approved Zafatek® tablets. TAD was monitored using TLC to ensure complete degradation. Furthermore, HPLC was used to confirm dealing with one major acid degradation product. The proposed methods were developed by manipulating zero-order, first-derivative, and ratio spectra of TRG and TAD using simultaneous equation, first-derivative, and mean-centering methods, respectively. Using Spectra Manager II and Minitab v.14 software, the absorbance at 274 nm-260.4 nm, amplitudes at 260.4 nm-274.0 nm, and mean-centered values at 287.6 nm-257.2 nm were measured against methanol as a blank for TRG and TAD, respectively. Linearity and the other validation parameters were acceptable at concentration ranges of 5-50  μ g/mL and 2.5-25  μ g/mL for TRG and TAD, respectively. Using one-way analysis of variance (ANOVA), the optimized methods were compared and proved to be accurate for the simultaneous assay of TRG and TAD.

  13. Liquid chromatography-tandem mass spectrometry method for determination of panel of neurotransmitters in cerebrospinal fluid from the rat model for tauopathy.

    PubMed

    Kovac, Andrej; Somikova, Zuzana; Zilka, Norbert; Novak, Michal

    2014-02-01

    Alzheimer's disease (AD) is still being recognized today as an unmet medical need. Currently, there is no cure and early preclinical diagnostic assay available for AD. Therefore much attention is now being directed at the development of novel methods for quantitative determination of AD biomarkers in the cerebrospinal fluid (CSF). Here, we describe the liquid chromatography-tandem mass spectrometry method for determination of 5-hydroxytryptamine (SER), 5-hydroxyindoleacetic acid (5-HIAA), homovanilic acid (HVA), noradrenaline (NADR), adrenaline (ADR), dopamine (DA), glutamic acid (Glu), γ-aminobutyric acid (GABA), 3,4-dihydroxyphenylacetic acid (DOPAC) and histamine (HIS) in cerebrospinal fluid (CSF) from the rat model for human tauopathy. The benzoyl chloride was used as pre-column derivatization reagents. Neurotransmitters and metabolites were analysed on ultra performance liquid chromatography (UPLC) on C18 column in combination with tandem mass spectrometry. The method is simple, highly sensitive and showed excellent linearity with regression coefficients higher than 0.99. The accuracy was in a range of 93-113% for all analytes. The inter-day precision (n=5 days), expressed as %RSD, was in a range 2-10% for all analytes. Using this method we detected significant changes of CSF levels of two important neurotransmitters/metabolites, ADR and 5-HIAA, which correlates with progression of neurodegeneration in our animal model. © 2013 Published by Elsevier B.V.

  14. DB2: a probabilistic approach for accurate detection of tandem duplication breakpoints using paired-end reads.

    PubMed

    Yavaş, Gökhan; Koyutürk, Mehmet; Gould, Meetha P; McMahon, Sarah; LaFramboise, Thomas

    2014-03-05

    With the advent of paired-end high throughput sequencing, it is now possible to identify various types of structural variation on a genome-wide scale. Although many methods have been proposed for structural variation detection, most do not provide precise boundaries for identified variants. In this paper, we propose a new method, Distribution Based detection of Duplication Boundaries (DB2), for accurate detection of tandem duplication breakpoints, an important class of structural variation, with high precision and recall. Our computational experiments on simulated data show that DB2 outperforms state-of-the-art methods in terms of finding breakpoints of tandem duplications, with a higher positive predictive value (precision) in calling the duplications' presence. In particular, DB2's prediction of tandem duplications is correct 99% of the time even for very noisy data, while narrowing down the space of possible breakpoints within a margin of 15 to 20 bps on the average. Most of the existing methods provide boundaries in ranges that extend to hundreds of bases with lower precision values. Our method is also highly robust to varying properties of the sequencing library and to the sizes of the tandem duplications, as shown by its stable precision, recall and mean boundary mismatch performance. We demonstrate our method's efficacy using both simulated paired-end reads, and those generated from a melanoma sample and two ovarian cancer samples. Newly discovered tandem duplications are validated using PCR and Sanger sequencing. Our method, DB2, uses discordantly aligned reads, taking into account the distribution of fragment length to predict tandem duplications along with their breakpoints on a donor genome. The proposed method fine tunes the breakpoint calls by applying a novel probabilistic framework that incorporates the empirical fragment length distribution to score each feasible breakpoint. DB2 is implemented in Java programming language and is freely available

  15. Single Laboratory Validated Method for Determination of Microcystins and Nodularin in Ambient Freshwaters by Solid Phase Extraction and Liquid Chromatography/ Tandem Mass Spectrometry (LC/MS/MS)

    EPA Pesticide Factsheets

    This document is a standardized, single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection of cyanotoxins—microsystins and nodularin (combined intracellular and extracellular)—in ambient freshwaters.

  16. Tandem Organic Light-Emitting Diodes.

    PubMed

    Fung, Man-Keung; Li, Yan-Qing; Liao, Liang-Sheng

    2016-12-01

    A tandem organic light-emitting diode (OLED) is an organic optoelectronic device that has two or more electroluminescence (EL) units connected electrically in series with unique intermediate connectors within the device. Researchers have studied this new OLED architecture with growing interest and have found that the current efficiency of a tandem OLED containing N EL units (N > 1) should be N times that of a conventional OLED containing only a single EL unit. Therefore, this new architecture is potentially useful for constructing high-efficiency, high-luminance, and long-lifetime OLED displays and organic solid-state lighting sources. In a tandem OLED, the intermediate connector plays a crucial role in determining the effectiveness of the stacked EL units. The interfaces in the connector control the inner charge generation and charge injection into the adjacent EL units. Meanwhile, the transparency and the thickness of the connector affect the light output of the device. Therefore, the intermediate connector should be made to meet both the electrical and optical requirements for achieving optimal performance. Here, recent advances in the research of the tandem OLEDs is discussed, with the main focus on material selection and interface studies in the intermediate connectors, as well as the optical design of the tandem OLEDs. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Observation method to predict meander migration and vertical degradation of rivers.

    DOT National Transportation Integrated Search

    2014-05-01

    Meander migration and vertical degradation of river bed are processes that have been studied for years. : Different methods have been proposed to make predictions of the behavior of rivers with respect to these : processes. These two erosion controll...

  18. Methods of Analysis by the U.S. Geological Survey Organic Geochemistry Research Group-Determination of Dissolved Isoxaflutole and Its Sequential Degradation Products, Diketonitrile and Benzoic Acid, in Water Using Solid-Phase Extraction and Liquid Chromatography/Tandem Mass Spectrometry

    USGS Publications Warehouse

    Meyer, Michael T.; Lee, Edward A.; Scribner, Elisabeth A.

    2007-01-01

    An analytical method for the determination of isoxaflutole and its sequential degradation products, diketonitrile and a benzoic acid analogue, in filtered water with varying matrices was developed by the U.S. Geological Survey Organic Geochemistry Research Group in Lawrence, Kansas. Four different water-sample matrices fortified at 0.02 and 0.10 ug/L (micrograms per liter) are extracted by vacuum manifold solid-phase extraction and analyzed by liquid chromatography/tandem mass spectrometry using electrospray ionization in negative-ion mode with multiple-reaction monitoring (MRM). Analytical conditions for mass spectrometry detection are optimized, and quantitation is carried out using the following MRM molecular-hydrogen (precursor) ion and product (p) ion transition pairs: 357.9 (precursor), 78.9 (p), and 277.6 (p) for isoxaflutole and diketonitrile, and 267.0 (precursor), 159.0 (p), and 223.1 (p) for benzoic acid. 2,4-dichlorophenoxyacetic acid-d3 is used as the internal standard, and alachlor ethanesulfonic acid-d5 is used as the surrogate standard. Compound detection limits and reporting levels are calculated using U.S. Environmental Protection Agency procedures. The mean solid-phase extraction recovery values ranged from 104 to 108 percent with relative standard deviation percentages ranging from 4.0 to 10.6 percent. The combined mean percentage concentration normalized to the theoretical spiked concentration of four water matrices analyzed eight times at 0.02 and 0.10 ug/L (seven times for the reagent-water matrix at 0.02 ug/L) ranged from approximately 75 to 101 percent with relative standard deviation percentages ranging from approximately 3 to 26 percent for isoxaflutole, diketonitrile, and benzoic acid. The method detection limit (MDL) for isoxaflutole and diketonitrile is 0.003 ug/L and 0.004 ug/L for benzoic acid. Method reporting levels (MRLs) are 0.011, 0.010, and 0.012 ug/L for isoxaflutole, diketonitrile, and benzoic acid, respectively. On the basis

  19. Method of phorbol ester degradation in Jatropha curcas L. seed cake using rice bran lipase.

    PubMed

    Hidayat, Chusnul; Hastuti, Pudji; Wardhani, Avita Kusuma; Nadia, Lana Santika

    2014-03-01

    A novel enzymatic degradation of phorbol esters (PE) in the jatropha seed cake was developed using lipase. Cihera rice bran lipase had the highest ability to hydrolyze PE, and reduced PE to a safe level after 8 h of incubation. Enzymatic degradation may be a promising method for PE degradation. Copyright © 2013 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  20. High temperature polymer degradation: Rapid IR flow-through method for volatile quantification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giron, Nicholas H.; Celina, Mathew C.

    Accelerated aging of polymers at elevated temperatures often involves the generation of volatiles. These can be formed as the products of oxidative degradation reactions or intrinsic pyrolytic decomposition as part of polymer scission reactions. A simple analytical method for the quantification of water, CO 2, and CO as fundamental signatures of degradation kinetics is required. Here, we describe an analytical framework and develops a rapid mid-IR based gas analysis methodology to quantify volatiles that are contained in small ampoules after aging exposures. The approach requires identification of unique spectral signatures, systematic calibration with known concentrations of volatiles, and a rapidmore » acquisition FTIR spectrometer for time resolved successive spectra. Furthermore, the volatiles are flushed out from the ampoule with dry N2 carrier gas and are then quantified through spectral and time integration. This method is sufficiently sensitive to determine absolute yields of ~50 μg water or CO 2, which relates to probing mass losses of less than 0.01% for a 1 g sample, i.e. the early stages in the degradation process. Such quantitative gas analysis is not easily achieved with other approaches. Our approach opens up the possibility of quantitative monitoring of volatile evolution as an avenue to explore polymer degradation kinetics and its dependence on time and temperature.« less

  1. High temperature polymer degradation: Rapid IR flow-through method for volatile quantification

    DOE PAGES

    Giron, Nicholas H.; Celina, Mathew C.

    2017-05-19

    Accelerated aging of polymers at elevated temperatures often involves the generation of volatiles. These can be formed as the products of oxidative degradation reactions or intrinsic pyrolytic decomposition as part of polymer scission reactions. A simple analytical method for the quantification of water, CO 2, and CO as fundamental signatures of degradation kinetics is required. Here, we describe an analytical framework and develops a rapid mid-IR based gas analysis methodology to quantify volatiles that are contained in small ampoules after aging exposures. The approach requires identification of unique spectral signatures, systematic calibration with known concentrations of volatiles, and a rapidmore » acquisition FTIR spectrometer for time resolved successive spectra. Furthermore, the volatiles are flushed out from the ampoule with dry N2 carrier gas and are then quantified through spectral and time integration. This method is sufficiently sensitive to determine absolute yields of ~50 μg water or CO 2, which relates to probing mass losses of less than 0.01% for a 1 g sample, i.e. the early stages in the degradation process. Such quantitative gas analysis is not easily achieved with other approaches. Our approach opens up the possibility of quantitative monitoring of volatile evolution as an avenue to explore polymer degradation kinetics and its dependence on time and temperature.« less

  2. Development and validation of a ultra high performance liquid chromatography-tandem mass spectrometric method for the direct detection of formoterol in human urine.

    PubMed

    Sardela, V F; Deventer, K; Pereira, H M G; de Aquino Neto, F R; Van Eenoo, P

    2012-11-01

    Formoterol is a long acting β(2)-agonist and has proven to be a very effective bronchodilating agent. Hence it is frequently applied therapeutically for the treatment of asthma. Because β(2)-agonists might be misused in sports for the stimulatory effects and for growth-promoting action their use is restricted. Since January 2012, formoterol is prohibited in urinary concentrations higher than 30 ng/mL. The objective of this study was to develop and validate a simple and robust ultra high performance liquid chromatographic-tandem mass spectrometric (UHPLC-MS/MS) method for the direct quantification of formoterol in urine. Sample preparation was limited to an enzymatic hydrolysis step after which 2 μL was injected in the chromatographic system. Chromatography was performed on a C(8)-column using gradient conditions. The mobile phase consisted of water/methanol (H(2)O/MeOH) both containing 0.1% acetic acid (HOAc) and 1mM ammonium acetate (NH(4)OAc). Calibration curve were constructed between 15 and 60 ng/mL. Validation data showed bias of 1.3% and imprecision of 5.4% at the threshold. Ion suppression/enhancement never exceeded 7%. Calculating measurement uncertainty showed proof of applicability of the method. Stability of formoterol was also investigated at 56 °C (accelerated stability test) at pH 1.0/5.2/7.0 and 9.5. At the physiological pH values of 5.2 and 7.0, formoterol showed good stability. At pH 1.0 and 9.5 significant degradation was observed. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Searching molecular structure databases with tandem mass spectra using CSI:FingerID

    PubMed Central

    Dührkop, Kai; Shen, Huibin; Meusel, Marvin; Rousu, Juho; Böcker, Sebastian

    2015-01-01

    Metabolites provide a direct functional signature of cellular state. Untargeted metabolomics experiments usually rely on tandem MS to identify the thousands of compounds in a biological sample. Today, the vast majority of metabolites remain unknown. We present a method for searching molecular structure databases using tandem MS data of small molecules. Our method computes a fragmentation tree that best explains the fragmentation spectrum of an unknown molecule. We use the fragmentation tree to predict the molecular structure fingerprint of the unknown compound using machine learning. This fingerprint is then used to search a molecular structure database such as PubChem. Our method is shown to improve on the competing methods for computational metabolite identification by a considerable margin. PMID:26392543

  4. The cell-in-series method: A technique for accelerated electrode degradation in redox flow batteries

    DOE PAGES

    Pezeshki, Alan M.; Sacci, Robert L.; Veith, Gabriel M.; ...

    2015-11-21

    Here, we demonstrate a novel method to accelerate electrode degradation in redox flow batteries and apply this method to the all-vanadium chemistry. Electrode performance degradation occurred seven times faster than in a typical cycling experiment, enabling rapid evaluation of materials. This method also enables the steady-state study of electrodes. In this manner, it is possible to delineate whether specific operating conditions induce performance degradation; we found that both aggressively charging and discharging result in performance loss. Post-mortem x-ray photoelectron spectroscopy of the degraded electrodes was used to resolve the effects of state of charge (SoC) and current on the electrodemore » surface chemistry. For the electrode material tested in this work, we found evidence that a loss of oxygen content on the negative electrode cannot explain decreased cell performance. Furthermore, the effects of decreased electrode and membrane performance on capacity fade in a typical cycling battery were decoupled from crossover; electrode and membrane performance decay were responsible for a 22% fade in capacity, while crossover caused a 12% fade.« less

  5. High voltage series connected tandem junction solar battery

    DOEpatents

    Hanak, Joseph J.

    1982-01-01

    A high voltage series connected tandem junction solar battery which comprises a plurality of strips of tandem junction solar cells of hydrogenated amorphous silicon having one optical path and electrically interconnected by a tunnel junction. The layers of hydrogenated amorphous silicon, arranged in a tandem configuration, can have the same bandgap or differing bandgaps. The tandem junction strip solar cells are series connected to produce a solar battery of any desired voltage.

  6. Degradation of learned skills. Effectiveness of practice methods on simulated space flight skill retention

    NASA Technical Reports Server (NTRS)

    Sitterley, T. E.; Berge, W. A.

    1972-01-01

    Manual flight control and emergency procedure task skill degradation was evaluated after time intervals of from 1 to 6 months. The tasks were associated with a simulated launch through the orbit insertion flight phase of a space vehicle. The results showed that acceptable flight control performance was retained for 2 months, rapidly deteriorating thereafter by a factor of 1.7 to 3.1 depending on the performance measure used. Procedural task performance showed unacceptable degradation after only 1 month, and exceeded an order of magnitude after 4 months. The effectiveness of static rehearsal (checklists and briefings) and dynamic warmup (simulator practice) retraining methods were compared for the two tasks. Static rehearsal effectively countered procedural skill degradation, while some combination of dynamic warmup appeared necessary for flight control skill retention. It was apparent that these differences between methods were not solely a function of task type or retraining method, but were a function of the performance measures used for each task.

  7. Different Spectrophotometric Methods for Simultaneous Determination of Trelagliptin and Its Acid Degradation Product

    PubMed Central

    Hassan, Mostafa A.; Zaghary, Wafaa A.

    2018-01-01

    New spectrophotometric and chemometric methods were carried out for the simultaneous assay of trelagliptin (TRG) and its acid degradation product (TAD) and applied successfully as a stability indicating assay to recently approved Zafatek® tablets. TAD was monitored using TLC to ensure complete degradation. Furthermore, HPLC was used to confirm dealing with one major acid degradation product. The proposed methods were developed by manipulating zero-order, first-derivative, and ratio spectra of TRG and TAD using simultaneous equation, first-derivative, and mean-centering methods, respectively. Using Spectra Manager II and Minitab v.14 software, the absorbance at 274 nm–260.4 nm, amplitudes at 260.4 nm–274.0 nm, and mean-centered values at 287.6 nm–257.2 nm were measured against methanol as a blank for TRG and TAD, respectively. Linearity and the other validation parameters were acceptable at concentration ranges of 5–50 μg/mL and 2.5–25 μg/mL for TRG and TAD, respectively. Using one-way analysis of variance (ANOVA), the optimized methods were compared and proved to be accurate for the simultaneous assay of TRG and TAD. PMID:29629213

  8. Retrieve polarization aberration from image degradation: a new measurement method in DUV lithography

    NASA Astrophysics Data System (ADS)

    Xiang, Zhongbo; Li, Yanqiu

    2017-10-01

    Detailed knowledge of polarization aberration (PA) of projection lens in higher-NA DUV lithographic imaging is necessary due to its impact to imaging degradations, and precise measurement of PA is conductive to computational lithography techniques such as RET and OPC. Current in situ measurement method of PA thorough the detection of degradations of aerial images need to do linear approximation and apply the assumption of 3-beam/2-beam interference condition. The former approximation neglects the coupling effect of the PA coefficients, which would significantly influence the accuracy of PA retrieving. The latter assumption restricts the feasible pitch of test masks in higher-NA system, conflicts with the Kirhhoff diffraction model of test mask used in retrieving model, and introduces 3D mask effect as a source of retrieving error. In this paper, a new in situ measurement method of PA is proposed. It establishes the analytical quadratic relation between the PA coefficients and the degradations of aerial images of one-dimensional dense lines in coherent illumination through vector aerial imaging, which does not rely on the assumption of 3-beam/2- beam interference and linear approximation. In this case, the retrieval of PA from image degradation can be convert from the nonlinear system of m-quadratic equations to a multi-objective quadratic optimization problem, and finally be solved by nonlinear least square method. Some preliminary simulation results are given to demonstrate the correctness and accuracy of the new PA retrieving model.

  9. Methods for locating ground faults and insulation degradation condition in energy conversion systems

    DOEpatents

    Agamy, Mohamed; Elasser, Ahmed; Galbraith, Anthony William; Harfman Todorovic, Maja

    2015-08-11

    Methods for determining a ground fault or insulation degradation condition within energy conversion systems are described. A method for determining a ground fault within an energy conversion system may include, in part, a comparison of baseline waveform of differential current to a waveform of differential current during operation for a plurality of DC current carrying conductors in an energy conversion system. A method for determining insulation degradation within an energy conversion system may include, in part, a comparison of baseline frequency spectra of differential current to a frequency spectra of differential current transient at start-up for a plurality of DC current carrying conductors in an energy conversion system. In one embodiment, the energy conversion system may be a photovoltaic system.

  10. Comparing Standard and Selective Degradation DNA Extraction Methods: Results from a Field Experiment with Sexual Assault Kits.

    PubMed

    Campbell, Rebecca; Pierce, Steven J; Sharma, Dhruv B; Shaw, Jessica; Feeney, Hannah; Nye, Jeffrey; Schelling, Kristin; Fehler-Cabral, Giannina

    2017-01-01

    A growing number of U.S. cities have large numbers of untested sexual assault kits (SAKs) in police property facilities. Testing older kits and maintaining current case work will be challenging for forensic laboratories, creating a need for more efficient testing methods. We evaluated selective degradation methods for DNA extraction using actual case work from a sample of previously unsubmitted SAKs in Detroit, Michigan. We randomly assigned 350 kits to either standard or selective degradation testing methods and then compared DNA testing rates and CODIS entry rates between the two groups. Continuation-ratio modeling showed no significant differences, indicating that the selective degradation method had no decrement in performance relative to customary methods. Follow-up equivalence tests indicated that CODIS entry rates for the two methods could differ by more than ±5%. Selective degradation methods required less personnel time for testing and scientific review than standard testing. © 2016 American Academy of Forensic Sciences.

  11. Analysis of the herbicide diuron, three diuron degradates, and six neonicotinoid insecticides in water-Method details and application to two Georgia streams

    USGS Publications Warehouse

    Hladik, Michelle; Calhoun, Daniel L.

    2012-01-01

    A method for the determination of the widely used herbicide diuron, three degradates of diuron, and six neonicotinoid insecticides in environmental water samples is described. Filtered water samples were extracted by using solid-phase extraction (SPE) with no additional cleanup steps. Quantification of the pesticides from the extracted water samples was done by using liquid chromatography with tandem mass spectrometry (LC/MS/MS). Recoveries in test water samples fortified at 20 nanograms per liter (ng/L) for each compound ranged from 75 to 97 percent; relative standard deviations ranged from 5 to 10 percent. Method detection limits (MDLs) in water ranged from 3.0 to 6.2 ng/L using LC/MS/MS. The method was applied to water samples from two streams in Georgia, Sope Creek and the Chattahoochee River. Diuron and 3,4-dichloroaniline (3,4-DCA) were detected in 100 and 80 percent, respectively, of the samples from the Chattahoochee River, whereas Sope creek had detection frequencies of 15 percent for diuron and 31 percent for 3,4-DCA. Detection frequencies for the neonicotinoid insecticide, imidacloprid, were 60 percent for the Chattahoochee River and 85 percent for Sope Creek. Field matrix-spike recoveries for each compound, when averaged over four water samples, ranged from 79 to 100 percent. The average percentage difference between replicate pairs for all compounds detected in the field samples was 10.1 (± 4.5) percent.

  12. Measurement of citrate in urine using liquid chromatography tandem mass spectrometry: comparison with an enzymatic method.

    PubMed

    Keevil, B G; Owen, L; Thornton, S; Kavanagh, J

    2005-09-01

    Measurement of urine citrate is used to assess the risk of further urinary stone formation and to assess the benefit of treatment in affected individuals. We wanted to develop a simple and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the analysis of urinary citrate and to compare it with our current enzymatic assay. For the LC-MS/MS assay, samples were prepared in a deep-well block by adding 10 microL of urine and 20 microL of internal standard to 400 microL of water. After mixing, 3 microL of the diluted sample was injected into the LC-MS/MS system. An LC system was used to isocratically elute a C18 column (50 x 2.1 mm) with 0.4 mL/min water containing 2 mmol/L ammonium acetate and 0.1% (v/v) formic acid. A step gradient of 100% methanol containing 2 mmol/L ammonium acetate and 0.1% (v/v) formic acid was used to wash the column. The retention times were 1.4 min for citrate and 1.4 min for d4-citrate. Cycle time was 4.0 min, injection to injection. The analytes were monitored using a tandem mass spectrometer operated in multiple reaction monitoring mode using the following transitions, citrate m/z 191.0>111.0 and d4-citrate m/z 195.0>113.0. Within and between-batch coefficients of variation were <3% over the range 480-3800 micromol/L. The lower limit of quantification was 24.0 micromol/L. Regression analysis showed LC-MS/MS = 0.8781 (enzymatic assay) + 102.5, r = 0.964, n = 73. We have developed a simple LC-MS/MS method for urinary citrate measurement that shows acceptable performance.

  13. Quantitative determination of hederagenin in rat plasma and cerebrospinal fluid by ultra fast liquid chromatography-tandem mass spectrometry method.

    PubMed

    Yang, Xuemei; Li, Guoliang; Chen, Lingyun; Zhang, Cong; Wan, Xinxiang; Xu, Jiangping

    2011-07-01

    A rapid, sensitive and selective method was developed for the quantitative determination of hederagenin in rat plasma and cerebrospinal fluid (CSF) by ultra fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS). It has been successfully applied in a pharmacokinetic study of hederagenin in the central nervous system (CNS). Sample pretreatment involved a simple protein precipitation with methanol and a one-step extraction with ethyl acetate. Separation was carried out in a Shim-pack XR-ODS II (75 mm × 2.0 mm, i.d., 2.1 μm) column with gradient elution at a flow rate of 0.35 mL/min. The mobile phase was 5mM ammonium acetate and acetonitrile. Detection was performed in a triple-quadruple tandem mass spectrometer by multiple-reaction-monitoring mode via electrospray ionization. A linear calibration curve for hederagenin was obtained over a concentration range of 0.406 (lower limit of quantification, LLOQ) to 203 ng/mL (r² > 0.99) for both plasma and CSF. The intra-day and inter-day precision (relative standard deviation, RSD) values were less than 15%. At all quality control (QC) levels, the accuracy (relative error, RE) was within -9.0% and 11.1% for plasma and CSF, respectively. The pharmacokinetics results indicated that hederagenin could pass through the blood-brain barrier. This UFLC-MS/MS method demonstrates higher sensitivity and sample throughput than previous methods. It was also successfully applied to the pharmacokinetic study of hederagenin following oral administration of Fructus akebiae extract in rats. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Robust optimization of a tandem grating solar thermal absorber

    NASA Astrophysics Data System (ADS)

    Choi, Jongin; Kim, Mingeon; Kang, Kyeonghwan; Lee, Ikjin; Lee, Bong Jae

    2018-04-01

    Ideal solar thermal absorbers need to have a high value of the spectral absorptance in the broad solar spectrum to utilize the solar radiation effectively. Majority of recent studies about solar thermal absorbers focus on achieving nearly perfect absorption using nanostructures, whose characteristic dimension is smaller than the wavelength of sunlight. However, precise fabrication of such nanostructures is not easy in reality; that is, unavoidable errors always occur to some extent in the dimension of fabricated nanostructures, causing an undesirable deviation of the absorption performance between the designed structure and the actually fabricated one. In order to minimize the variation in the solar absorptance due to the fabrication error, the robust optimization can be performed during the design process. However, the optimization of solar thermal absorber considering all design variables often requires tremendous computational costs to find an optimum combination of design variables with the robustness as well as the high performance. To achieve this goal, we apply the robust optimization using the Kriging method and the genetic algorithm for designing a tandem grating solar absorber. By constructing a surrogate model through the Kriging method, computational cost can be substantially reduced because exact calculation of the performance for every combination of variables is not necessary. Using the surrogate model and the genetic algorithm, we successfully design an effective solar thermal absorber exhibiting a low-level of performance degradation due to the fabrication uncertainty of design variables.

  15. Evaluation of an in vitro faecal degradation method for early assessment of the impact of colonic degradation on colonic absorption in humans.

    PubMed

    Tannergren, Christer; Borde, Anders; Boreström, Cecilia; Abrahamsson, Bertil; Lindahl, Anders

    2014-06-16

    The objective of this study was to develop and evaluate an in vitro method to investigate bacterial-mediated luminal degradation of drugs in colon in humans. This would be a valuable tool for the assessment of drug candidates during early drug development, especially for compounds intended to be developed as oral extended release formulations. Freshly prepared faecal homogenate from healthy human volunteers (n=3-18), dog (n=6) and rat (colon and caecal content, n=3) was homogenised with 3.8 parts (w/w) physiological saline under anaerobical conditions. Four model compounds (almokalant, budesonide, ximelagatran and metoprolol) were then incubated (n=3-18) separately in the human faecal homogenate for up to 120min at 37°C. In addition, ximelagatran was also incubated in the faecal or colonic content from dog and rat. The mean (±SD) in vitro half-life for almokalant, budesonide and ximelagatran was 39±1, 68±21 and 26±12min, respectively, in the human faecal homogenate. Metoprolol was found to be stable in the in vitro model. The in vitro degradation data was then compared to literature data on fraction absorbed after direct colon administration in humans. The percentage of drug remaining after 60min of in vitro incubation correlated (R(2)=0.90) with the fraction absorbed from colon in humans. The mean in vitro half-life of ximelagatran was similar in human faeces (26±12min) and rat colon content (34±31min), but significantly (p<0.05) longer in rat caecum content (50±11min) and dog faeces (126±17min). The in vitro method is in vivo relevant both qualitatively as all the model drugs that undergoes colonic degradation in vivo was rapidly degraded in the faecal homogenates as well as quantitatively since a correlation was established between percentage degraded in vitro at 60min and fraction absorbed in the colon for the model drugs, which have no other absorption limiting properties. Also, the method is easy to use from a technical point of view, which suggests

  16. Determination and Safety Assessment of Residual Spirotetramat and Its Metabolites in Amaranth (Amaranthus tricolor) and Soil by Liquid Chromatography Triple-Quadrupole Tandem Mass Spectrometry.

    PubMed

    Chen, Xiao-Jun; Meng, Zhi-Yuan; Ren, Li; Song, Yue-Yi; Ren, Ya-Jun; Chen, Jian-Shu; Guan, Ling-Jun

    2018-05-01

    With the purpose of guaranteeing the safe use of spirotetramat and preventing its potential health threats to consumers, a QuEChERS extraction method coupled with LC triple-quadrupole tandem MS was applied in this study to determine residual spirotetramat metabolites in different tissues of amaranth (Amaranthus tricolor) and in soil. The results indicate that the spirotetramat degraded into different types of metabolites that were located in different tissues of amaranth and in soil. B-keto, B-glu, and B-enol were the three most representative degradation products in the leaf of amaranth, and B-glu and B-enol were the two major degradation products found in the stem of amaranth; however, only B-enol was detected in the root of amaranth. B-keto and B-mono were the two products detected in the soil in which the amaranth grew. The cytotoxicity results demonstrate that spirotetramat and its metabolite B-enol inhibited cellular growth, and the toxicity of spirotetramat and its metabolite B-enol exceeded than that of the metabolites B-keto, B-mono, and B-glu. This investigation is of great significance to the safe use of spirotetramat in agriculture.

  17. Study of degradation behaviour of montelukast sodium and its marketed formulation in oxidative and accelerated test conditions and prediction of physicochemical and ADMET properties of its degradation products using ADMET Predictor™.

    PubMed

    Tiwari, Shobhit Kumar; Singh, Dilip Kumar; Ladumor, Mayurbhai Kathadbhai; Chakraborti, Asit K; Singh, Saranjit

    2018-05-26

    Study of oxidative stability of pharmaceutical actives and formulations is important as oxidation pathway is the second most significant route for the decay of pharmaceuticals. Montelukast sodium, a leukotriene receptor antagonist, is prone to oxidation reactions owing to sensitive moieties in its structure. It is also known to be light sensitive. This study was aimed to understand the degradation behaviour of the drug in different oxidative media containing hydrogen peroxide, AIBN, Fe 3+ , Fenton's reagent and O 2 environment under normal laboratory light conditions. The degradation behaviour of the drug was also evaluated in solid sate under ICH recommended accelerated stability condition of 40 °C/75% RH to correlate with the degradation products (DPs) formed in a solid oral formulation. A total of nine DPs (MTK 1 to MTK 9) were formed from both the drug substance and the marketed tablet formulation on storage under controlled oxygen environment in normal laboratory light and temperature conditions. These DPs were well separated on a C-18 column using a gradient HPLC method. The characterization of DPs was done based on HRMS and multi-stage tandem mass spectrometric (MS n ) data. The knowledge of the structure of DPs helped in laying down degradation pathway of the drug. Also, mechanism for the formation of each DP was postulated. Finally, physicochemical as well as absorption, distribution, metabolism, excretion and toxicity (ADMET) properties of the DPs were predicted by ADMET Predictor™ software. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Tandem mass spectrometry data quality assessment by self-convolution.

    PubMed

    Choo, Keng Wah; Tham, Wai Mun

    2007-09-20

    Many algorithms have been developed for deciphering the tandem mass spectrometry (MS) data sets. They can be essentially clustered into two classes. The first performs searches on theoretical mass spectrum database, while the second based itself on de novo sequencing from raw mass spectrometry data. It was noted that the quality of mass spectra affects significantly the protein identification processes in both instances. This prompted the authors to explore ways to measure the quality of MS data sets before subjecting them to the protein identification algorithms, thus allowing for more meaningful searches and increased confidence level of proteins identified. The proposed method measures the qualities of MS data sets based on the symmetric property of b- and y-ion peaks present in a MS spectrum. Self-convolution on MS data and its time-reversal copy was employed. Due to the symmetric nature of b-ions and y-ions peaks, the self-convolution result of a good spectrum would produce a highest mid point intensity peak. To reduce processing time, self-convolution was achieved using Fast Fourier Transform and its inverse transform, followed by the removal of the "DC" (Direct Current) component and the normalisation of the data set. The quality score was defined as the ratio of the intensity at the mid point to the remaining peaks of the convolution result. The method was validated using both theoretical mass spectra, with various permutations, and several real MS data sets. The results were encouraging, revealing a high percentage of positive prediction rates for spectra with good quality scores. We have demonstrated in this work a method for determining the quality of tandem MS data set. By pre-determining the quality of tandem MS data before subjecting them to protein identification algorithms, spurious protein predictions due to poor tandem MS data are avoided, giving scientists greater confidence in the predicted results. We conclude that the algorithm performs well

  19. Improvement and validation of a high-performance liquid chromatography in tandem mass spectrometry method for monitoring of omeprazole in plasma.

    PubMed

    Wojnicz, Aneta; Gil García, Ana Isabel; Román-Martínez, Manuel; Ochoa-Mazarro, Dolores; Abad-Santos, Francisco; Ruiz-Nuño, Ana

    2015-06-01

    Omeprazole (OME) is a proton pump inhibitor with a 58% bioavailability after a single oral dose. It is subject to marked interindividual variations and significant drug-drug interactions. The authors developed a simple and rapid method based on liquid chromatography in tandem with mass spectrometry with solid phase extraction and isotope-labeled internal standard to monitor plasma levels of OME in pharmacokinetics and drug-drug interaction studies. OME and its internal standard (OME-D3) were eluted with a Zorbax Extend C-18 rapid resolution column (4.6 × 50 mm, 3.5 μm) at 25°C, under isocratic conditions through a mobile phase consisting of 1 mM ammonium acetate, pH 8.5 (55%), and acetonitrile (45%). The flow rate was 0.8 mL/min, and the chromatogram run time was 1.2 minutes. OME was detected and quantified by liquid chromatography in tandem with mass spectrometry with positive electrospray ionization, which operates in multiple-reaction monitoring mode. The method was linear in the range of 1.5-2000 ng/mL for OME. The validation assays for accuracy and precision, matrix effect, extraction recovery, and stability of the samples for OME did not deviate more than 20% for the lower limit of quantification and no more than 15% for other quality controls. These findings are consistent with the requirements of regulatory agencies. The method enables rapid quantification of OME concentrations and can be used in pharmacokinetic and drug-drug interaction studies.

  20. 47 CFR 69.129 - Signalling for tandem switching.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 3 2011-10-01 2011-10-01 false Signalling for tandem switching. 69.129 Section... (CONTINUED) ACCESS CHARGES Computation of Charges § 69.129 Signalling for tandem switching. A charge that is... provision of signalling for tandem switching. [59 FR 32930, June 27, 1994] ...

  1. 47 CFR 69.129 - Signalling for tandem switching.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Signalling for tandem switching. 69.129 Section... (CONTINUED) ACCESS CHARGES Computation of Charges § 69.129 Signalling for tandem switching. A charge that is... provision of signalling for tandem switching. [59 FR 32930, June 27, 1994] ...

  2. 47 CFR 69.129 - Signalling for tandem switching.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 3 2013-10-01 2013-10-01 false Signalling for tandem switching. 69.129 Section... (CONTINUED) ACCESS CHARGES Computation of Charges § 69.129 Signalling for tandem switching. A charge that is... provision of signalling for tandem switching. [59 FR 32930, June 27, 1994] ...

  3. 47 CFR 69.129 - Signalling for tandem switching.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 3 2012-10-01 2012-10-01 false Signalling for tandem switching. 69.129 Section... (CONTINUED) ACCESS CHARGES Computation of Charges § 69.129 Signalling for tandem switching. A charge that is... provision of signalling for tandem switching. [59 FR 32930, June 27, 1994] ...

  4. [Establishment and evaluation of an in vitro method for neutrophil extracellular trap generation and degradation].

    PubMed

    Li, Jinlong; Zhang, Yidan; Zhou, Xin; Ji, Wenjie; Zhao, Jihong; Wei, Luqing; Li, Yuming

    2014-09-01

    To evaluate a novel method for in vitro generation and degradation of neutrophil extracellular traps (NETs), which are a newly recognized structure that is involved in the pathogenesis of autoimmune diseases and thrombosis. Neutrophils from peripheral blood of healthy donors were obtained by Ficoll-Histopaque gradient separation. NET release was initiated by phorbol myristate acetate (PMA) and validated by immunofluorescence staining and agarose gel electrophoresis. NETs degraded by DNase I and healthy human plasma were quantified by fluorescence spectrometry after staining with PicoGreen. HE staining showed that the purity of neutrophils was up to 95% after Ficoll-Histopaque gradient separation. NET immunofluorescent staining revealed that the network structure was mainly composed of DNA and histones, with molecular length more than 10 kb as demonstrated by agarose gel electrophoresis. Moreover, both DNase and healthy human plasma could induce the degradation of NETs, in varying degrees. This work established an efficient method for in vitro generation and degradation of human NETs.

  5. Stability-indicating methods for the determination of piretanide in presence of the alkaline induced degradates.

    PubMed

    Youssef, Nadia F

    2005-10-04

    Stability-indicating high performance liquid chromatography (HPLC), thin-layer chromatography (TLC) and first-derivative of ratio spectra (1DD) methods are developed for the determination of piretanide in presence of its alkaline induced degradates. HPLC method depends on separation of piretanide from its degradates on mu-Bondapak C18 column using methanol:water:acetic acid (70:30:1, v/v/v) as a mobile phase at flow rate 1.0 ml/min and UV detector at 275 nm. TLC densitometic method is based on the difference in Rf-values between the intact drug and its degradates on thin-layer silica gel. Iso-propanol:ammonia 33% (8:2, v/v) was used as a developing mobile phase and the chromatogram was scanned at 275 nm. The derivative of ratio spectra method (1DD) depends on the measurement of the absorbance at 288 nm in the first-derivative of ratio spectra for the determination of the cited drug in the presence of its degradates. Calibration graphs of the three suggested methods are linear in the concentration ranges 0.02-0.3 microg/20 microl, 0.5-10 microg/spot and 5-50 microg/ml, with mean percentage recovery 99.27+/-0.52, 99,17+/-1.01 and 99.65+/-1.01%, respectively. The three proposed methods were successfully applied for the determination of piretanide in bulk powder, laboratory-prepared mixtures and pharmaceutical dosage form with good accuracy and precision. The results were statistically analyzed and compared with those obtained by the official method. Validation of the method was determined with favourable specificity, linearity, precision, and accuracy was assessed by applying the standard addition technique.

  6. Production of multicharged metal ion beams on the first stage of tandem-type ECRIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagino, Shogo, E-mail: hagino@nf.eie.eng.osaka-u.ac.jp; Nagaya, Tomoki; Nishiokada, Takuya

    2016-02-15

    Multicharged metal ion beams are required to be applied in a wide range of fields. We aim at synthesizing iron-endohedral fullerene by transporting iron ion beams from the first stage into the fullerene plasma in the second stage of the tandem-type electron cyclotron resonance ion source (ECRIS). We developed new evaporators by using a direct ohmic heating method and a radiation heating method from solid state pure metal materials. We investigate their properties in the test chamber and produce iron ions on the first stage of the tandem-type ECRIS. As a result, we were successful in extracting Fe{sup +} ionmore » beams from the first stage and introducing Fe{sup +} ion beams to the second stage. We will try synthesizing iron-endohedral fullerene on the tandem-type ECRIS by using these evaporators.« less

  7. Ruggedness testing and validation of a practical analytical method for > 100 veterinary drug residues in bovine muscle by ultrahigh performance liquid chromatography – tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    In this study, optimization, extension, and validation of a streamlined, qualitative and quantitative multiclass, multiresidue method was conducted to monitor great than100 veterinary drug residues in meat using ultrahigh-performance liquid chromatography – tandem mass spectrometry (UHPLC-MS/MS). I...

  8. Method for Impeding Degradation of Porous Silicon Structures

    NASA Technical Reports Server (NTRS)

    Vilentchouk, Biana Godin; Ferrari, Mauro

    2011-01-01

    This invention relates to surface modification of porosified silicon (pSi) structures with poly(alkylene) glycols for the purpose of controlled degradation of the silicon matrix and tailored release of encapsulated substances for biomedical applications. The pSi structures are currently used in diverse biomedical applications including bio-molecular screening, optical bio-sensoring, and drug delivery by means of injectable/orally administered carriers and implantable devices. The size of the pores and the surface chemistry of the pSi structure can be controlled during the microfabrication process and thereafter. A fine regulation of the degradation kinetics of mesoporous silicon structures is of fundamental importance. Polyethylene glycols (PEGs) represent the major category of surface modifying agents used in classical drug delivery systems and in pharmaceutical dosage forms. PEGylation enables avoidance of RES uptake, thus prolonging circulation time of intravenously injectable nanovectors. PEG molecules demonstrate little toxicity and immunogenicity, and are cleared from the body through the urine (molecular weight, MW less than 30 kDa) or in the feces (MW greater than 30kDa). The invention focuses on the possibility of finely tuning the degradation kinetics of the pSi nanovectors and other structures through surface conjugation of PEGs with various backbone lengths/MWs. To prove the concept, pSi nanovectors were covalently conjugated to seven PEGs with MW from 245 to 5,000 Da and their degradation kinetics in physiologically relevant media (phosphate buffer saline, PBS pH7.4, and fetal bovine serum) was assessed by the elemental analysis of the Si using inductive coupled plasma atomic emission spectroscopy (ICP-AES). The conjugation of the PEG with lowest MW to the nanovectors surface did not induce any change in the degradation kinetics in serum, but inhibited degradation and consequently the release of orthosilicic acid into buffer. When PEGs with the longer

  9. Comprehensive analysis of pyrimidine metabolism in 450 children with unspecific neurological symptoms using high-pressure liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Schmidt, C; Hofmann, U; Kohlmüller, D; Mürdter, T; Zanger, U M; Schwab, M; Hoffmann, G F

    2005-01-01

    To evaluate the significance of inborn metabolic disorders of the pyrimidine degradation pathway, 450 children with unspecific neurological symptoms were comprehensively studied; 200 healthy children were recruited as controls. Uracil and thymine as well as their degradation products in urine were determined with an improved method based on reversed-phase HPLC coupled with electrospray ionization tandem mass spectrometry and detection by multiple-reaction monitoring using stable-isotope-labelled reference compounds as internal standards. From the results of the control group we established age-related reference ranges of all pyrimidine degradation products. In the patient group, two children with dihydropyrimidine dehydrogenase (DPYD) deficiency were identified; one of these was homozygous for the exon 14-skipping mutation of the DPYD gene. In addition, two patients with high uracil, dihydrouracil and beta-ureidopropionate were found to have ornithine transcarbamylase deficiency. In the urine of 9 patients, beta-alanine was markedly elevated owing to treatment with vigabatrin, an irreversible inhibitor of GABA transaminase, which interferes with beta-alanine breakdown. Four patients had exclusively high levels of beta-aminoisobutyrate (beta-AIB) due to a low activity of the D-beta-AIB-pyruvate aminotransferase, probably without clinical significance. In conclusion, quantitative investigation of pyrimidine metabolites in children with unexplained neurological symptoms, particularly epileptic seizures with or without psychomotor retardation, can be recommended as a helpful tool for diagnosis in clinical practice. Sensitive methods and age-related reference ranges enable the detection of partial enzyme deficiencies.

  10. Comparative evaluation of two dose optimization methods for image-guided, highly-conformal, tandem and ovoids cervix brachytherapy planning

    NASA Astrophysics Data System (ADS)

    Ren, Jiyun; Menon, Geetha; Sloboda, Ron

    2013-04-01

    Although the Manchester system is still extensively used to prescribe dose in brachytherapy (BT) for locally advanced cervix cancer, many radiation oncology centers are transitioning to 3D image-guided BT, owing to the excellent anatomy definition offered by modern imaging modalities. As automatic dose optimization is highly desirable for 3D image-based BT, this study comparatively evaluates the performance of two optimization methods used in BT treatment planning—Nelder-Mead simplex (NMS) and simulated annealing (SA)—for a cervix BT computer simulation model incorporating a Manchester-style applicator. Eight model cases were constructed based on anatomical structure data (for high risk-clinical target volume (HR-CTV), bladder, rectum and sigmoid) obtained from measurements on fused MR-CT images for BT patients. D90 and V100 for HR-CTV, D2cc for organs at risk (OARs), dose to point A, conformation index and the sum of dwell times within the tandem and ovoids were calculated for optimized treatment plans designed to treat the HR-CTV in a highly conformal manner. Compared to the NMS algorithm, SA was found to be superior as it could perform optimization starting from a range of initial dwell times, while the performance of NMS was strongly dependent on their initial choice. SA-optimized plans also exhibited lower D2cc to OARs, especially the bladder and sigmoid, and reduced tandem dwell times. For cases with smaller HR-CTV having good separation from adjoining OARs, multiple SA-optimized solutions were found which differed markedly from each other and were associated with different choices for initial dwell times. Finally and importantly, the SA method yielded plans with lower dwell time variability compared with the NMS method.

  11. Comparative efficacy of multimodal digital methods in assessing trail/resource degradation

    Treesearch

    Logan O. Park

    2014-01-01

    Outdoor recreation can cause both positive and negative impacts on associated forest ecosystems. Forest recreation trails localize negative impacts to a controlled spatial extent while providing recreation access beyond developed areas and transportation networks. Current methods for assessing extent and severity of trail and proximal resource degradation require...

  12. The behavior of compression and degradation for municipal solid waste and combined settlement calculation method.

    PubMed

    Shi, Jianyong; Qian, Xuede; Liu, Xiaodong; Sun, Long; Liao, Zhiqiang

    2016-09-01

    The total compression of municipal solid waste (MSW) consists of primary, secondary, and decomposition compressions. It is usually difficult to distinguish between the three parts of compressions. In this study, the odeometer test was used to distinguish between the primary and secondary compressions to determine the primary and secondary compression coefficient. In addition, the ending time of the primary compressions were proposed based on municipal solid waste compression tests in a degradation-inhibited condition by adding vinegar. The amount of the secondary compression occurring in the primary compression stage has a relatively high percentage to either the total compression or the total secondary compression. The relationship between the degradation ratio and time was obtained from the tests independently. Furthermore, a combined compression calculation method of municipal solid waste for all three parts of compressions including considering organics degradation is proposed based on a one-dimensional compression method. The relationship between the methane generation potential L0 of LandGEM model and degradation compression index was also discussed in the paper. A special column compression apparatus system, which can be used to simulate the whole compression process of municipal solid waste in China, was designed. According to the results obtained from 197-day column compression test, the new combined calculation method for municipal solid waste compression was analyzed. The degradation compression is the main part of the compression of MSW in the medium test period. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Methods for the visualization and analysis of extracellular matrix protein structure and degradation.

    PubMed

    Leonard, Annemarie K; Loughran, Elizabeth A; Klymenko, Yuliya; Liu, Yueying; Kim, Oleg; Asem, Marwa; McAbee, Kevin; Ravosa, Matthew J; Stack, M Sharon

    2018-01-01

    This chapter highlights methods for visualization and analysis of extracellular matrix (ECM) proteins, with particular emphasis on collagen type I, the most abundant protein in mammals. Protocols described range from advanced imaging of complex in vivo matrices to simple biochemical analysis of individual ECM proteins. The first section of this chapter describes common methods to image ECM components and includes protocols for second harmonic generation, scanning electron microscopy, and several histological methods of ECM localization and degradation analysis, including immunohistochemistry, Trichrome staining, and in situ zymography. The second section of this chapter details both a common transwell invasion assay and a novel live imaging method to investigate cellular behavior with respect to collagen and other ECM proteins of interest. The final section consists of common electrophoresis-based biochemical methods that are used in analysis of ECM proteins. Use of the methods described herein will enable researchers to gain a greater understanding of the role of ECM structure and degradation in development and matrix-related diseases such as cancer and connective tissue disorders. © 2018 Elsevier Inc. All rights reserved.

  14. A new non-degradative method to purify glycogen.

    PubMed

    Tan, Xinle; Sullivan, Mitchell A; Gao, Fei; Li, Shihan; Schulz, Benjamin L; Gilbert, Robert G

    2016-08-20

    Liver glycogen, a complex branched glucose polymer containing a small amount of protein, is important for maintaining glucose homeostasis (blood-sugar control) in humans. It has recently been found that glycogen molecular structure is impaired in diabetes. Isolating the carbohydrate polymer and any intrinsically-attached protein(s) is an essential prerequisite for studying this structural impairment. This requires an effective, non-degradative and efficient purification method to exclude the many other proteins present in liver. Proteins and glycogen have different ranges of molecular sizes. Despite the plethora of proteins that might still be present in significant abundance after other isolation techniques, SEC (size exclusion chromatography, also known as GPC), which separates by molecular size, should separate those extraneous to glycogen from glycogen with any intrinsically associated protein(s). A novel purification method is developed for this, based on preparative SEC following sucrose gradient centrifugation. Proteomics is used to show that the new method compares favourably with current methods in the literature. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method

    PubMed Central

    Jahan, Md. Sarowar; Islam, Md. Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R2) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R2 > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0–103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5–20%, according to the guideline of ICH), while paracetamol showed <20% degradation in oxidation and basic condition. PMID:25452691

  16. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method.

    PubMed

    Jahan, Md Sarowar; Islam, Md Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R (2)) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R (2) > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0-103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5-20%, according to the guideline of ICH), while paracetamol showed <20% degradation in oxidation and basic condition.

  17. An efficient and environment-friendly method of removing graphene oxide in wastewater and its degradation mechanisms.

    PubMed

    Zhang, Chao-Zhi; Li, Ting; Yuan, Yang; Xu, Jianqiang

    2016-06-01

    Graphene and graphene oxide (GO) have already existed in air, water and soil due to their popular application in functional materials. However, degradation of graphene and GO in wastewater has not been reported. Degradation of GO plays a key role in the elimination of graphene and GO in wastewater due to graphene being easily oxidized to GO. In this paper, GO was completely degraded to give CO2 by Photo-Fenton. The degradation intermediates were determined by UV-vis absorption spectra, elemental analysis (EA), fourier transform infrared (FT-IR) and liquid chromatography-mass spectrometry (LC-MS). Experimental results showed that graphene oxide was completely degraded to give CO2 after 28 days. Based on UV, FT-IR, LC-MS spectra and EA data of these degradation intermediates, the degradation mechanisms of GO were supposed. This paper suggests an efficient and environment-friendly method to degrade GO and graphene. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Simulation study of GaAsP/Si tandem cells including the impact of threading dislocations on the luminescent coupling between the cells

    NASA Astrophysics Data System (ADS)

    Onno, Arthur; Harder, Nils-Peter; Oberbeck, Lars; Liu, Huiyun

    2016-03-01

    A model, derived from the detailed balance model from Shockley and Queisser, has been adapted to monolithically grown GaAsP/Si tandem dual junction solar cells. In this architecture, due to the difference of lattice parameters between the silicon bottom cell - acting as the substrate - and the GaAsP top cell, threading dislocations (TDs) arise at the IIIV/ Si interface and propagate in the top cell. These TDs act as non-radiative recombination centers, degrading the performances of the tandem cell. Our model takes into account the impact of TDs by integrating the NTT model developed by Yamaguchi et. al.. Two surface geometries have been investigated: flat and ideally textured. Finally the model considers the luminescent coupling (LC) between the cells due to reemitted photons from the top cell cascading to the bottom cell. Without dislocations, LC allows a greater flexibility in the cell design by rebalancing the currents between the two cells when the top cell presents a higher short-circuit current. However we show that, as the TD density (TDD) increases, nonradiative recombinations take over radiative recombinations in the top cell and the LC is quenched. As a result, nonoptimized tandem cells with higher short-circuit current in the top cell experience a very fast degradation of efficiency for TDDs over 104cm-2. On the other hand optimized cells with matching currents only experience a small efficiency drop for TDDs up to 105cm-2. High TDD cells therefore need to be current-matched for optimal performances as the flexibility due to LC is lost.

  19. Stability indicating methods for the analysis of cefprozil in the presence of its alkaline induced degradation product

    NASA Astrophysics Data System (ADS)

    Attia, Khalid A. M.; Nassar, Mohammed W. I.; El-Zeiny, Mohamed B.; Serag, Ahmed

    2016-04-01

    Three simple, specific, accurate and precise spectrophotometric methods were developed for the determination of cefprozil (CZ) in the presence of its alkaline induced degradation product (DCZ). The first method was the bivariate method, while the two other multivariate methods were partial least squares (PLS) and spectral residual augmented classical least squares (SRACLS). The multivariate methods were applied with and without variable selection procedure (genetic algorithm GA). These methods were tested by analyzing laboratory prepared mixtures of the above drug with its alkaline induced degradation product and they were applied to its commercial pharmaceutical products.

  20. Development of a High-Performance Liquid Chromatography–Tandem Mass Spectrometry Method for the Identification and Quantification of CP-47,497, CP-47,497-C8 and JWH-250 in Mouse Brain

    PubMed Central

    Samano, Kimberly L.; Poklis, Justin L.; Lichtman, Aron H.; Poklis, Alphonse

    2014-01-01

    While Marijuana continues to be the most widely used illicit drug, abuse of synthetic cannabinoid (SCB) compounds in ‘Spice’ or ‘K2’ herbal incense products has emerged as a significant public health concern in many European countries and in the USA. Several of these SCBs have been declared Schedule I controlled substances but detection and quantification in biological samples remain a challenge. Therefore, we present a liquid chromatography–tandem mass spectrometry method after liquid–liquid extraction for the quantitation of CP-47,497, CP-47,497-C8 and JWH-250 in mouse brain. We report data for linearity, limit of quantification, accuracy/bias, precision, recovery, selectivity, carryover, matrix effects and stability experiments which were developed and fully validated based on Scientific Working Group for Forensic Toxicology guidelines for forensic toxicology method validation. Acceptable coefficients of variation for accuracy/bias, within- and between-run precision and selectivity were determined, with all values within ±15% of the target concentration. Validation experiments revealed degradation of CP-47, 497 and CP-47,497-C8 at different temperatures, and significant ion suppression was produced in brain for all compounds tested. The method was successfully applied to detect and quantify CP-47,497 in brains from mice demonstrating significant cannabimimetic behavioral effects as assessed by the classical tetrad paradigm. PMID:24816398

  1. Tandem Translation Classroom: A Case Study

    ERIC Educational Resources Information Center

    Kim, Dohun; Koh, Taejin

    2018-01-01

    The transition to student-centred learning, advances in teleconferencing tools, and active international student exchange programmes have stimulated tandem learning in many parts of the world. This pedagogical model is based on a mutual language exchange between tandem partners, where each student is a native speaker in the language the…

  2. Displacement of particles in microfluidics by laser-generated tandem bubbles

    NASA Astrophysics Data System (ADS)

    Lautz, Jaclyn; Sankin, Georgy; Yuan, Fang; Zhong, Pei

    2010-11-01

    The dynamic interaction between laser-generated tandem bubble and individual polystyrene particles of 2 and 10 μm in diameter is studied in a microfluidic channel (25 μm height) by high-speed imaging and particle image velocimetry. The asymmetric collapse of the tandem bubble produces a pair of microjets and associated long-lasting vortices that can propel a single particle to a maximum velocity of 1.4 m/s in 30 μs after the bubble collapse with a resultant directional displacement up to 60 μm in 150 μs. This method may be useful for high-throughput cell sorting in microfluidic devices.

  3. Tandem catalysis for the preparation of cylindrical polypeptide brushes.

    PubMed

    Rhodes, Allison J; Deming, Timothy J

    2012-11-28

    Here, we report a method for synthesis of cylindrical copolypeptide brushes via N-carboxyanhydride (NCA) polymerization utilizing a new tandem catalysis approach that allows preparation of brushes with controlled segment lengths in a straightforward, one-pot procedure requiring no intermediate isolation or purification steps. To obtain high-density brush copolypeptides, we used a "grafting from" approach where alloc-α-aminoamide groups were installed onto the side chains of NCAs to serve as masked initiators. These groups were inert during cobalt-initiated NCA polymerization and gave allyloxycarbonyl-α-aminoamide-substituted polypeptide main chains. The alloc-α-aminoamide groups were then activated in situ using nickel to generate initiators for growth of side-chain brush segments. This use of stepwise tandem cobalt and nickel catalysis was found to be an efficient method for preparation of high-chain-density, cylindrical copolypeptide brushes, where both the main chains and side chains can be prepared with controlled segment lengths.

  4. Thermodynamic characterization of tandem mismatches found in naturally occurring RNA

    PubMed Central

    Christiansen, Martha E.; Znosko, Brent M.

    2009-01-01

    Although all sequence symmetric tandem mismatches and some sequence asymmetric tandem mismatches have been thermodynamically characterized and a model has been proposed to predict the stability of previously unmeasured sequence asymmetric tandem mismatches [Christiansen,M.E. and Znosko,B.M. (2008) Biochemistry, 47, 4329–4336], experimental thermodynamic data for frequently occurring tandem mismatches is lacking. Since experimental data is preferred over a predictive model, the thermodynamic parameters for 25 frequently occurring tandem mismatches were determined. These new experimental values, on average, are 1.0 kcal/mol different from the values predicted for these mismatches using the previous model. The data for the sequence asymmetric tandem mismatches reported here were then combined with the data for 72 sequence asymmetric tandem mismatches that were published previously, and the parameters used to predict the thermodynamics of previously unmeasured sequence asymmetric tandem mismatches were updated. The average absolute difference between the measured values and the values predicted using these updated parameters is 0.5 kcal/mol. This updated model improves the prediction for tandem mismatches that were predicted rather poorly by the previous model. This new experimental data and updated predictive model allow for more accurate calculations of the free energy of RNA duplexes containing tandem mismatches, and, furthermore, should allow for improved prediction of secondary structure from sequence. PMID:19509311

  5. Development of a liquid chromatography-tandem mass spectrometry method for quantitative analysis of trace d-amino acids.

    PubMed

    Nakano, Yosuke; Konya, Yutaka; Taniguchi, Moyu; Fukusaki, Eiichiro

    2017-01-01

    d-Amino acids have recently attracted much attention in various research fields including medical, clinical and food industry due to their important biological functions that differ from l-amino acid. Most chiral amino acid separation techniques require complicated derivatization procedures in order to achieve the desirable chromatographic behavior and detectability. Thus, the aim of this research is to develop a highly sensitive analytical method for the enantioseparation of chiral amino acids without any derivatization process using liquid chromatography-tandem mass spectrometry (LC-MS/MS). By optimizing MS/MS parameters, we established a quantification method that allowed the simultaneous analysis of 18 d-amino acids with high sensitivity and reproducibility. Additionally, we applied the method to food sample (vinegar) for the validation, and successfully quantified trace levels of d-amino acids in samples. These results demonstrated the applicability and feasibility of the LC-MS/MS method as a novel, effective tool for d-amino acid measurement in various biological samples. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  6. [Liquid chromatography-tandem mass spectrometry method for determination of 10 macrolide antibiotics in pork samples using on-line solid phase extraction purification].

    PubMed

    Zhang, Xiaoguang; Liu, Dong; Liu, Hongran; Li, Qiang; Li, Lili; Wang, Lixia; Zhang, Yan

    2017-10-08

    A high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method based on-line solid phase extraction (SPE) purification was established to determine 10 macrolide antibiotics in pork samples. The samples were extracted with acetonitrile, and the extracts were dried with rotary evaporator at 40℃, then the analytes were dissolved with 2 mL phosphate buffer. The solutions were purified and concentrated by on-line SPE with HLB cartridges. The analytes were eluted with methanol, and then transferred to XBridge BEH C18 column, separated with the mobile phases of 10 mmol/L ammonium acetate aqueous solution and acetonitrile. Finally, the target analytes were detected by tandem mass spectrometry. The results showed that good linearity was obtained in the range of 0.1-200 μg/L for the 10 macrolide antibiotics with correlation coefficients better than 0.990. The limits of detection were in range of 0.05-0.30 μg/kg and the limits of quantitation were in range of 0.10-1.00 μg/kg. The recoveries of the method were in range of 69.6%-115.2% at the spiked levels of 0.10-10.0 μg/kg for all analytes, with the relative standard deviations less than 10%. The developed method can be used for the determination of the 10 macrolide antibiotics in pork samples.

  7. Enantioselective degradation of Myclobutanil and Famoxadone in grape.

    PubMed

    Lin, Chunmian; Zhang, Lijun; Zhang, Hu; Wang, Qiang; Zhu, Jiahong; Wang, Jianmei; Qian, Mingrong

    2018-01-01

    The enantioselective degradation of myclobutanil and famoxadone enantiomers in grape under open field was investigated in this study. The absolute configuration of myclobutanil and famoxadone enantiomers was determined by the combination of experimental electronic circular dichroism (ECD) and calculated ECD spectra. The enantiomers residues of myclobutanil and famoxadone in grape were measured by sensitive high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS). The linearity, precision, accuracy, matrix effect, and stability were assessed. And the limit of quantification (LOQ) for each enantiomer of myclobutanil and famoxadone in grape was evaluated to be 1.5 and 2 μg kg -1 . The myclobutanil and famoxadone showed the enantioselective degradation in grape, and the enantioselectivity of degradation for myclobutanil was more pronounced than that for famoxadone. The half-lives were 13.1 days and 25.7 days for S-(+)-myclobutanil and R-(-)-myclobutanil in grape, separately. The half-life of S-(+)-famoxadone was 31.5 days slightly shorter than that of R-(-)-famoxadone with half-life being 38.5 days in grape. The probable reasons for the enantioselective degradation behavior of these two fungicides were also discussed. The results in the article might provide a reference to better assess the risks of myclobutanil and famoxadone enantiomers in grapes to human and environment. Graphical abstract The enantioselective analysis of myclobutanil and famoxadone in grape.

  8. Selecting tandem partners for silicon solar cells [Selecting tandem partners for silicon solar cells using spectral efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Zhengshan; Leilaeioun, Mehdi; Holman, Zachary

    Combining silicon and other materials in tandem solar cells is one approach to enhancing the overall power conversion efficiency of the cells. Here, we argue that top cell partners for silicon tandem solar cells should be selected on the basis of their spectral efficiency — their efficiency resolved by wavelength.

  9. Selecting tandem partners for silicon solar cells [Selecting tandem partners for silicon solar cells using spectral efficiency

    DOE PAGES

    Yu, Zhengshan; Leilaeioun, Mehdi; Holman, Zachary

    2016-09-26

    Combining silicon and other materials in tandem solar cells is one approach to enhancing the overall power conversion efficiency of the cells. Here, we argue that top cell partners for silicon tandem solar cells should be selected on the basis of their spectral efficiency — their efficiency resolved by wavelength.

  10. Kinetics and degradation pathways of photolytic and photocatalytic oxidation of the anthelmintic drug praziquantel.

    PubMed

    Čizmić, Mirta; Ljubas, Davor; Ćurković, Lidija; Škorić, Irena; Babić, Sandra

    2017-02-05

    In this study, an anthelmintic drug, praziquantel(PZQ), was degraded using the direct photolysis, photocatalysis, and oxidation processes including UV radiation, TiO 2 film, and hydrogen peroxide. The photolytic degradation with predominant wavelengths of 185/254nm (UV-C) proved to be more efficient with a half-life of 3.13min compared to the radiation of 365nm (UV-A) where the degradation did not occur. In order to enhance the rate of PZQ photolytic degradation, H 2 O 2 was added, which resulted in two to three times higher degradation rates. In the photocatalytic degradation, TiO 2 film was used as catalyst. The degradation was ten times faster in the photocatalytic experiments where UV-C light (k=0.2390min -1 ) was used than in those with UV-A (k=0.0201min -1 ). Comparing the results from all performed experiments it can be concluded that the UV-C/TiO 2 /H 2 O 2 process yielded the highest degradation rate and complete degradation of PZQ was obtained in less than 7min. The degradation of PZQ followed the first order kinetics in all the experiments. The photo degradation was inhibited in the presence of methanol. The degradation pathways and the structural formulae of five degradation products (m/z 273, 269, 189, 147, 132) were proposed based on the liquid chromatography tandem mass spectrometry analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Bifacial tandem solar cells

    DOEpatents

    Wojtczuk, Steven J.; Chiu, Philip T.; Zhang, Xuebing; Gagnon, Edward; Timmons, Michael

    2016-06-14

    A method of fabricating on a semiconductor substrate bifacial tandem solar cells with semiconductor subcells having a lower bandgap than the substrate bandgap on one side of the substrate and with subcells having a higher bandgap than the substrate on the other including, first, growing a lower bandgap subcell on one substrate side that uses only the same periodic table group V material in the dislocation-reducing grading layers and bottom subcells as is present in the substrate and after the initial growth is complete and then flipping the substrate and growing the higher bandgap subcells on the opposite substrate side which can be of different group V material.

  12. Nondestructive testing methods to predict effect of degradation on wood : a critical assessment

    Treesearch

    J. Kaiserlik

    1978-01-01

    Results are reported for an assessment of methods for predicting strength of wood, wood-based, or related material. Research directly applicable to nondestructive strength prediction was very limited. In wood, strength prediction research is limited to vibration decay, wave attenuation, and multiparameter "degradation models." Nonwood methods with potential...

  13. Development and validation of two liquid chromatography-tandem mass spectrometry methods for the determination of silibinin and silibinin hemisuccinate in human plasma.

    PubMed

    Sala, Federica; Albares, Pablo; Colovic, Milena; Persiani, Stefano; Rovati, Lucio C

    2014-01-15

    To investigate the pharmacokinetics of silibinin and silibinin hemisuccinate in human plasma, two high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) methods were developed and validated. The methods require a small volume of sample (100μL), and the recovery of the analytes was complete with a good reproducibility (CV% 1.7-9.5), after a simple protein precipitation. Naringenin was used as internal standard. The chromatographic methods provided a good separation of diastereoisomers A and B of both silibinin and silibinin hemisuccinate onto a Chromolith Performance RP18e 100mm×3mm column, with a resolution of peaks from plasma matrix in less than 6min. The methods precision values expressed as CV% were always ≤6.2% and the accuracy was always well within the acceptable 15% range. Quantification was performed on a triple-quadrupole tandem mass spectrometer by Selected Reaction Monitoring (SRM) mode, in a negative ion mode, via electrospray ionization (ESI). The lower limit of quantitation was set at 5.0ng/mL (silibinin) and 25.0ng/mL (silibinin hemisuccinate), and the linearity was validated up to 1000.0 and 12,500.0ng/mL, for silibinin and silibinin hemisuccinate, respectively, with correlation coefficients (R(2)) of 0.991 or better. The methods were suitable for pharmacokinetic studies and were successfully applied to human plasma samples from subjects treated intravenously with Legalon(®) SIL at the dose of 20mg/kg, expressed as silibinin. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Tandem junction amorphous silicon solar cells

    DOEpatents

    Hanak, Joseph J.

    1981-01-01

    An amorphous silicon solar cell has an active body with two or a series of layers of hydrogenated amorphous silicon arranged in a tandem stacked configuration with one optical path and electrically interconnected by a tunnel junction. The layers of hydrogenated amorphous silicon arranged in tandem configuration can have the same bandgap or differing bandgaps.

  15. The Dynamics of Social Interaction in Telecollaborative Tandem Exchanges

    ERIC Educational Resources Information Center

    Janssen Sanchez, Brianna

    2015-01-01

    Using both quantitative and qualitative methods of inquiry, this dissertation study undertakes an exploration of the dynamics of the social interaction in discourse co-constructed by pairs of college students in telecollaborative tandem exchanges. Two groups of participants, Mexican learners of English as a foreign language and American learners…

  16. Three degradation pathways of 1-octyl-3-methylimidazolium cation by activated sludge from wastewater treatment process.

    PubMed

    Cho, Chul-Woong; Pham, Thi Phuong Thuy; Kim, Sok; Song, Myung-Hee; Chung, Yun-Jo; Yun, Yeoung-Sang

    2016-03-01

    The biodegradability and degradation pathways of 1-octyl-3-methylimidazolium cation [OMIM](+) by microbial community of wastewater treatment plant in Jeonju city, Korea were investigated. It was found that [OMIM](+) could be easily degraded by the microbial community. New degradation products and pathways of [OMIM](+) were identified, which are partially different from previous results (Green Chem. 2008, 10, 214-224). For the analysis of the degradation pathways and intermediates, the mass peaks observed in the range m/z of 50-300 were screened by using a tandem mass spectrometer (MS), and their fragmentation patterns were investigated by MS/MS. Surprisingly, we found three different degradation pathways of [OMIM](+), which were separated according to the initially oxidized position i.e. middle of the long alkyl chain, end of the long alkyl chain, and end of the short alkyl chain. The degradation pathways showed that the long and short alkyl chains of [OMIM](+) gradually degraded by repeating oxidation and carbon release. The results presented here shows that [OMIM](+) can be easily biodegraded through three different degradation pathways in wastewater treatment plants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Method and compositions for the degradation of tributyl phosphate in chemical waste mixtures

    DOEpatents

    Stoner, Daphne L.; Tien, Albert J.

    1995-01-01

    A method and process for the degradation of tributyl phosphate in an organic waste mixture and a biologically pure, novel bacteria culture for accomplishing the same. A newly-discovered bacteria (a strain of Acinetobacter sp. ATCC 55587) is provided which is combined in a reactor vessel with a liquid waste mixture containing tributyl phosphate and one or more organic waste compounds capable of functioning as growth substrates for the bacteria. The bacteria is thereafter allowed to incubate within the waste mixture. As a result, the tributyl phosphate and organic compounds within the waste mixture are metabolized (degraded) by the bacteria, thereby eliminating such materials which are environmentally hazardous. In addition, the bacteria is capable of degrading waste mixtures containing high quantities of tributyl phosphate (e.g. up to about 1.0% by weight tributyl phosphate).

  18. High-Efficiency Polycrystalline Thin Film Tandem Solar Cells.

    PubMed

    Kranz, Lukas; Abate, Antonio; Feurer, Thomas; Fu, Fan; Avancini, Enrico; Löckinger, Johannes; Reinhard, Patrick; Zakeeruddin, Shaik M; Grätzel, Michael; Buecheler, Stephan; Tiwari, Ayodhya N

    2015-07-16

    A promising way to enhance the efficiency of CIGS solar cells is by combining them with perovskite solar cells in tandem devices. However, so far, such tandem devices had limited efficiency due to challenges in developing NIR-transparent perovskite top cells, which allow photons with energy below the perovskite band gap to be transmitted to the bottom cell. Here, a process for the fabrication of NIR-transparent perovskite solar cells is presented, which enables power conversion efficiencies up to 12.1% combined with an average sub-band gap transmission of 71% for photons with wavelength between 800 and 1000 nm. The combination of a NIR-transparent perovskite top cell with a CIGS bottom cell enabled a tandem device with 19.5% efficiency, which is the highest reported efficiency for a polycrystalline thin film tandem solar cell. Future developments of perovskite/CIGS tandem devices are discussed and prospects for devices with efficiency toward and above 27% are given.

  19. Stability-indicating spectrophotometric methods for determination of the anticoagulant drug apixaban in the presence of its hydrolytic degradation product

    NASA Astrophysics Data System (ADS)

    Tantawy, Mahmoud A.; El-Ragehy, Nariman A.; Hassan, Nagiba Y.; Abdelkawy, Mohamed

    2016-04-01

    Apixaban (a novel anticoagulant agent) was subjected to a stress stability study including acid, alkali, oxidative, photolytic, and thermal degradation. The drug was found to be only liable to acidic and alkaline hydrolysis. The degradation product was then isolated and identified by IR and GC-mass spectrometry. Four spectrophotometric methods, namely; first derivative (D1), derivative ratio (DR), ratio difference (RD) and mean centering of ratio spectra (MCR), have been suggested for the determination of apixaban in presence of its hydrolytic degradation product. The proposed methods do not require any preliminary separation step. The accuracy, precision and linearity ranges of the proposed methods were determined, and the methods were validated as per ICH guidelines and the specificity was assessed by analyzing synthetic mixtures containing different percentages of the degradation product with the drug. The developed methods were successfully applied for the determination of apixaban in bulk powder and its tablet dosage form.

  20. Stability-indicating spectrophotometric methods for determination of the anticoagulant drug apixaban in the presence of its hydrolytic degradation product.

    PubMed

    Tantawy, Mahmoud A; El-Ragehy, Nariman A; Hassan, Nagiba Y; Abdelkawy, Mohamed

    2016-04-15

    Apixaban (a novel anticoagulant agent) was subjected to a stress stability study including acid, alkali, oxidative, photolytic, and thermal degradation. The drug was found to be only liable to acidic and alkaline hydrolysis. The degradation product was then isolated and identified by IR and GC-mass spectrometry. Four spectrophotometric methods, namely; first derivative (D(1)), derivative ratio (DR), ratio difference (RD) and mean centering of ratio spectra (MCR), have been suggested for the determination of apixaban in presence of its hydrolytic degradation product. The proposed methods do not require any preliminary separation step. The accuracy, precision and linearity ranges of the proposed methods were determined, and the methods were validated as per ICH guidelines and the specificity was assessed by analyzing synthetic mixtures containing different percentages of the degradation product with the drug. The developed methods were successfully applied for the determination of apixaban in bulk powder and its tablet dosage form. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Novel Biochar-Plant Tandem Approach for Remediating Hexachlorobenzene Contaminated Soils: Proof-of-Concept and New Insight into the Rhizosphere.

    PubMed

    Song, Yang; Li, Yang; Zhang, Wei; Wang, Fang; Bian, Yongrong; Boughner, Lisa A; Jiang, Xin

    2016-07-13

    Volatilization of semi/volatile persistent organic pollutants (POPs) from soils is a major source of global POPs emission. This proof-of-concept study investigated a novel biochar-plant tandem approach to effectively immobilize and then degrade POPs in soils using hexachlorobenzene (HCB) as a model POP and ryegrass (Lolium perenne L.) as a model plant growing in soils amended with wheat straw biochar. HCB dissipation was significantly enhanced in the rhizosphere and near rhizosphere soils, with the greatest dissipation in the 2 mm near rhizosphere. This enhanced HCB dissipation likely resulted from (i) increased bioavailability of immobilized HCB and (ii) enhanced microbial activities, both of which were induced by ryegrass root exudates. As a major component of ryegrass root exudates, oxalic acid suppressed HCB sorption to biochar and stimulated HCB desorption from biochar and biochar-amended soils, thus increasing the bioavailability of HCB. High-throughput sequencing results revealed that the 2 mm near rhizosphere soil showed the lowest bacterial diversity due to the increased abundance of some genera (e.g., Azohydromonas, Pseudomonas, Fluviicola, and Sporocytophaga). These bacteria were likely responsible for the enhanced degradation of HCB as their abundance was exponentially correlated with HCB dissipation. The results from this study suggest that the biochar-plant tandem approach could be an effective strategy for remediating soils contaminated with semi/volatile organic contaminants.

  2. Form-Focused Interaction in Online Tandem Learning

    ERIC Educational Resources Information Center

    O'Rourke, Breffni

    2005-01-01

    Tandem language learning--a configuration involving pairs of learners with complementary target/native languages--is an underexploited but potentially very powerful use of computer-mediated communication (CMC) in second-language pedagogy. Tandem offers the benefits of authentic, culturally grounded interaction, while also promoting a pedagogical…

  3. Method and compositions for the degradation of tributyl phosphate in chemical waste mixtures

    DOEpatents

    Stoner, D.L.; Tien, A.J.

    1995-09-26

    A method and process are disclosed for the degradation of tributyl phosphate in an organic waste mixture and a biologically pure, novel bacteria culture for accomplishing the same. A newly-discovered bacteria (a strain of Acinetobacter sp. ATCC 55587) is provided which is combined in a reactor vessel with a liquid waste mixture containing tributyl phosphate and one or more organic waste compounds capable of functioning as growth substrates for the bacteria. The bacteria is thereafter allowed to incubate within the waste mixture. As a result, the tributyl phosphate and organic compounds within the waste mixture are metabolized (degraded) by the bacteria, thereby eliminating such materials which are environmentally hazardous. In addition, the bacteria is capable of degrading waste mixtures containing high quantities of tributyl phosphate (e.g. up to about 1.0% by weight tributyl phosphate). 6 figs.

  4. Electronic Tandem Language Learning (eTandem): A Third Approach to Second Language Learning for the 21st Century

    ERIC Educational Resources Information Center

    Cziko, Gary A.

    2004-01-01

    Tandem language learning occurs when two learners of different native languages work together to help each other learn the other language. First used in face-to-face contexts, Tandem is now increasingly being used by language-learning partners located in different countries who are linked via various forms of electronic communication, a context…

  5. A thin film degradation study of a fluorinated polyether liquid lubricant using an HPLC method

    NASA Technical Reports Server (NTRS)

    Morales, W.

    1986-01-01

    A High Pressure Liquid Chromatography (HPLC) separation method was developed to study and analyze a fluorinated polyether fluid which is promising liquid lubricant for future applications. This HPLC separation method was used in a preliminary study investigating the catalytic effect of various metal, metal alloy, and ceramic engineering materials on the degradation of this fluid in a dry air atmosphere at 345 C. Using a 440 C stainless steel as a reference catalytic material it was found that a titanium alloy and a chromium plated material degraded the fluorinated polyether fluid substantially more than the reference material.

  6. High-Throughput Analytical Techniques for Determination of Residues of 653 Multiclass Pesticides and Chemical Pollutants in Tea, Part VI: Study of the Degradation of 271 Pesticide Residues in Aged Oolong Tea by Gas Chromatography-Tandem Mass Spectrometry and Its Application in Predicting the Residue Concentrations of Target Pesticides.

    PubMed

    Chang, Qiao-Ying; Pang, Guo-Fang; Fan, Chun-Lin; Chen, Hui; Wang, Zhi-Bin

    2016-07-01

    The degradation rate of 271 pesticide residues in aged Oolong tea at two spray concentrations, named a and b (a < b), were monitored for 120 days using GC-tandem MS (GC-MS/MS). To research the degradation trends and establish regression equations, determination days were plotted as horizontal ordinates and the residue concentrations of pesticide were plotted as vertical ordinates. Here, we consider the degradation equations of 271 pesticides over 40 and 120 days, summarize the degradation rates in six aspects (A-F), and discuss the degradation trends of the 271 pesticides in aged Oolong tea in detail. The results indicate that >70% of the determined pesticides coincide with the degradation regularity of trends A, B, and E, i.e., the concentration of pesticide will decrease within 4 months. Next, 20 representative pesticides were selected for further study at higher spray concentrations, named c and d (d > c > b > a), in aged Oolong tea over another 90 days. The determination days were plotted on the x-axis, and the differences between each determined result and first-time-determined value of target pesticides were plotted on the y-axis. The logarithmic function was obtained by fitting the 90-day determination results, allowing the degradation value of a target pesticide on a specific day to be calculated. These logarithmic functions at d concentration were applied to predict the residue concentrations of pesticides at c concentration. Results revealed that 70% of the 20 pesticides had the lower deviation ratios of predicted and measured results.

  7. Validated stability-indicating spectrophotometric methods for the determination of cefixime trihydrate in the presence of its acid and alkali degradation products.

    PubMed

    Mostafa, Nadia M; Abdel-Fattah, Laila; Weshahy, Soheir A; Hassan, Nagiba Y; Boltia, Shereen A

    2015-01-01

    Five simple, accurate, precise, and economical spectrophotometric methods have been developed for the determination of cefixime trihydrate (CFX) in the presence of its acid and alkali degradation products without prior separation. In the first method, second derivative (2D) and first derivative (1D) spectrophotometry was applied to the absorption spectra of CFX and its acid (2D) or alkali (1D) degradation products by measuring the amplitude at 289 and 308 nm, respectively. The second method was a first derivative (1DD) ratio spectrophotometric method where the peak amplitudes were measured at 311 nm in presence of the acid degradation product, and 273 and 306 nm in presence of its alkali degradation product. The third method was ratio subtraction spectrophotometry where the drug is determined at 286 nm in laboratory-prepared mixtures of CFX and its acid or alkali degradation product. The fourth method was based on dual wavelength analysis; two wavelengths were selected at which the absorbances of one component were the same, so wavelengths 209 and 252 nm were used to determine CFX in presence of its acid degradation product and 310 and 321 nm in presence of its alkali degradation product. The fifth method was bivariate spectrophotometric calibration based on four linear regression equations obtained at the wavelengths 231 and 290 nm, and 231 and 285 nm for the binary mixture of CFX with either its acid or alkali degradation product, respectively. The developed methods were successfully applied to the analysis of CFX in laboratory-prepared mixtures and pharmaceutical formulations with good recoveries, and their validation was carried out following the International Conference on Harmonization guidelines. The results obtained were statistically compared with each other and showed no significant difference with respect to accuracy and precision.

  8. Persistence of alprazolam in river water according to forced and non-forced degradation assays: adsorption to sediment and long-term degradation products.

    PubMed

    Jiménez, Juan J; Sánchez, María I; Muñoz, Beatriz E; Pardo, Rafael

    2017-08-01

    Alprazolam is a pharmaceutical compound that it is detected in surface waters. Some degradation studies in aqueous solutions and pharmaceutical products are available, but there is no reliable information about its stability in river water. Here, assays have been conducted under forced biological, photochemical, and thermal conditions, and under non-forced conditions, to estimate the fate of alprazolam in river water and know its degradation products. The forced assays indicated that the biological and photochemical degradation of alprazolam was negligible; heating at 70°C for a long time barely affected it. The degradation of alprazolam in river water at 100 μg/L was about 5% after 36 weeks, keeping the water under a natural day-night cycle at room temperature and limiting partially the exposure to sunlight as happens inside a body of water; no change in concentration was observed when the monitoring was performed at 2 μg/L. The results suggest the persistence of alprazolam in surface water and a possible accumulation over time. Residues were monitored by ultra-pressure liquid chromatography/quadrupole time-of-flight/mass spectrometry after solid-phase extraction; nine degradation products were found and the structures for most of them were proposed from the molecular formulae and fragmentation observed in high-resolution tandem mass spectra. (5-chloro-2-(3-methyl-4H-1,2,4-triazol-4-yl)phenyl)(phenyl)methanol was the main long-term transformation product in conditions that simulate those in a mass of water. The degradation rate in presence of sediment was equally very low under non-forced conditions; adsorption coefficients of alprazolam and major degradation products were calculated. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Simultaneous determination of 24 polycyclic aromatic hydrocarbons in edible oil by tandem solid-phase extraction and gas chromatography coupled/tandem mass spectrometry.

    PubMed

    Xu, Ting; Tang, Hua; Chen, Dazhou; Dong, Haifeng; Li, Lei

    2015-01-01

    An efficient and fast tandem SPE method followed by GC/MS/MS has been developed for the determination and the quantification of 24 polycyclic aromatic hydrocarbons (PAHs) in edible oil. This method includes the monitoring of 15 + 1 PAHs designated as a priority by the European Union in their 2005/108/EC recommendation and 16 PAHs listed by the U. S. Environmental Protection Agency. The sample preparation procedures were based on SPE in which PAH-dedicated cartridges with molecularly imprinted polymers and graphitized carbon black were used in series. The novel tandem SPE combination of selective extraction and purification of light and heavy PAHs provided highly purified analytes. Identification and quantification of 24 target PAHs were performed using GC/MS/MS with the isotope dilution approaches using D-labeled and (13)C-labeled PAHs. The advantages of GC/MS/MS as compared to other detection methods include high sensitivity, selectivity, and interpretation ability. The method showed satisfactory linearity (R(2) > 0.998) over the range assayed (0.5-200 μg/kg); the LODs ranged from 0.03 to 0.6 μg/kg, and LOQs from 0.1 to 2.0 μg/kg. The recoveries using this method at three spiked concentration levels (2, 10, and 50 μg/kg) ranged from 56.8 to 117.7%. The RSD was lower than 12.7% in all cases. The proposed analytical method has been successfully applied for the analysis of the 24 PAHs in edible oil.

  10. 47 CFR 69.111 - Tandem-switched transport and tandem charge.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., geographically averaged on a study-area-wide basis, that the incumbent local exchange carrier experiences based... exchange carrier experiences based on the prior year's annual use. Tandem-switched transport transmission..., geographically averaged on a study-area-wide basis, that the incumbent local exchange carrier experiences based...

  11. Analytical methods for toxic gases from thermal degradation of polymers

    NASA Technical Reports Server (NTRS)

    Hsu, M.-T. S.

    1977-01-01

    Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

  12. A sensitive and selective liquid chromatography/tandem mass spectrometry method for quantitative analysis of efavirenz in human plasma.

    PubMed

    Srivastava, Praveen; Moorthy, Ganesh S; Gross, Robert; Barrett, Jeffrey S

    2013-01-01

    A selective and a highly sensitive method for the determination of the non-nucleoside reverse transcriptase inhibitor (NNRTI), efavirenz, in human plasma has been developed and fully validated based on high performance liquid chromatography tandem mass spectrometry (LC-MS/MS). Sample preparation involved protein precipitation followed by one to one dilution with water. The analyte, efavirenz was separated by high performance liquid chromatography and detected with tandem mass spectrometry in negative ionization mode with multiple reaction monitoring. Efavirenz and ¹³C₆-efavirenz (Internal Standard), respectively, were detected via the following MRM transitions: m/z 314.20243.90 and m/z 320.20249.90. A gradient program was used to elute the analytes using 0.1% formic acid in water and 0.1% formic acid in acetonitrile as mobile phase solvents, at a flow-rate of 0.3 mL/min. The total run time was 5 min and the retention times for the internal standard (¹³C₆-efavirenz) and efavirenz was approximately 2.6 min. The calibration curves showed linearity (coefficient of regression, r>0.99) over the concentration range of 1.0-2,500 ng/mL. The intraday precision based on the standard deviation of replicates of lower limit of quantification (LLOQ) was 9.24% and for quality control (QC) samples ranged from 2.41% to 6.42% and with accuracy from 112% and 100-111% for LLOQ and QC samples. The inter day precision was 12.3% and 3.03-9.18% for LLOQ and quality controls samples, and the accuracy was 108% and 95.2-108% for LLOQ and QC samples. Stability studies showed that efavirenz was stable during the expected conditions for sample preparation and storage. The lower limit of quantification for efavirenz was 1 ng/mL. The analytical method showed excellent sensitivity, precision, and accuracy. This method is robust and is being successfully applied for therapeutic drug monitoring and pharmacokinetic studies in HIV-infected patients.

  13. A Sensitive and Selective Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitative Analysis of Efavirenz in Human Plasma

    PubMed Central

    Srivastava, Praveen; Moorthy, Ganesh S.; Gross, Robert; Barrett, Jeffrey S.

    2013-01-01

    A selective and a highly sensitive method for the determination of the non-nucleoside reverse transcriptase inhibitor (NNRTI), efavirenz, in human plasma has been developed and fully validated based on high performance liquid chromatography tandem mass spectrometry (LC–MS/MS). Sample preparation involved protein precipitation followed by one to one dilution with water. The analyte, efavirenz was separated by high performance liquid chromatography and detected with tandem mass spectrometry in negative ionization mode with multiple reaction monitoring. Efavirenz and 13C6-efavirenz (Internal Standard), respectively, were detected via the following MRM transitions: m/z 314.20243.90 and m/z 320.20249.90. A gradient program was used to elute the analytes using 0.1% formic acid in water and 0.1% formic acid in acetonitrile as mobile phase solvents, at a flow-rate of 0.3 mL/min. The total run time was 5 min and the retention times for the internal standard (13C6-efavirenz) and efavirenz was approximately 2.6 min. The calibration curves showed linearity (coefficient of regression, r>0.99) over the concentration range of 1.0–2,500 ng/mL. The intraday precision based on the standard deviation of replicates of lower limit of quantification (LLOQ) was 9.24% and for quality control (QC) samples ranged from 2.41% to 6.42% and with accuracy from 112% and 100–111% for LLOQ and QC samples. The inter day precision was 12.3% and 3.03–9.18% for LLOQ and quality controls samples, and the accuracy was 108% and 95.2–108% for LLOQ and QC samples. Stability studies showed that efavirenz was stable during the expected conditions for sample preparation and storage. The lower limit of quantification for efavirenz was 1 ng/mL. The analytical method showed excellent sensitivity, precision, and accuracy. This method is robust and is being successfully applied for therapeutic drug monitoring and pharmacokinetic studies in HIV-infected patients. PMID:23755102

  14. Quantification of the Barkhausen noise method for the evaluation of time-dependent degradation

    NASA Astrophysics Data System (ADS)

    Kim, Dong-Won; Kwon, Dongil

    2003-02-01

    The Barkhausen noise (BN) method has long been applied to measure the bulk magnetic properties of magnetic materials. Recently, this important nondestructive testing (NDT) method has been applied to evaluate microstructure, stress distribution analysis, fatigue, creep and fracture characteristics. Until now the BN method has been used only qualitatively in evaluating the variation of BN with variations in material properties. For this reason, few NDT methods have been applied in industrial plants and laboratories. The present investigation studied the coercive force and BN while varying the microstructure of ultrafine-grained steels and SA508 cl.3 steels. This variation was carried out according to the second heat-treatment condition with rolling of ultrafine-grained steels and the simulated time-dependent degradation of SA 508 cl.3 steels. An attempt was also made to quantify BN from the relationship between the velocity of magnetic domain walls and the retarding force, using the coercive force of the domain wall movement. The microstructure variation was analyzed according to time-dependent degradation. Fracture toughness was evaluated quantitatively by measuring the BN from two intermediary parameters; grain size and distribution of nonmagnetic particles. From these measurements, the variation of microstructure and fracture toughness can be directly evaluated by the BN method as an accurate in situ NDT method.

  15. Photocatalytic degradation of methylene blue dye by zinc oxide nanoparticles obtained from precipitation and sol-gel methods.

    PubMed

    Balcha, Abebe; Yadav, Om Prakash; Dey, Tania

    2016-12-01

    Zinc oxide (ZnO) nanoparticles were synthesized by precipitation and sol-gel methods. The aim of this study was to understand how different synthetic methods can affect the photocatalytic activity of ZnO nanoparticles. As-synthesized ZnO nanoparticles were characterized by X-ray diffraction (XRD) and UV-Visible spectroscopic techniques. XRD patterns of ZnO powders synthesized by precipitation and sol-gel methods revealed their hexagonal wurtzite structure with crystallite sizes of 30 and 28 nm, respectively. Their photocatalytic activities were evaluated by photocatalytic degradation of methylene blue, a common water pollutant, under UV radiation. The effects of operational parameters such as photocatalyst load and initial concentration of the dye on photocatalytic degradation of methylene blue were investigated. While the degradation of dye decreased over the studied dye concentration range of 20 to 100 mg/L, an optimum photocatalyst load of 250 mg/L was needed to achieve dye degradation as high as 81 and 92.5 % for ZnO prepared by precipitation and sol-gel methods, respectively. Assuming pseudo first-order reaction kinetics, this corresponded to rate constants of 8.4 × 10 -3 and 12.4 × 10 -3  min -1 , respectively. Hence, sol-gel method is preferred over precipitation method in order to achieve higher photocatalytic activity of ZnO nanostructures. Photocatalytic activity is further augmented by better choice of capping ligand for colloidal stabilization, starch being more effective than polyethylene glycol (PEG).

  16. Variable Number Of Tandem Repeats (VNTR) and its application in bacterial epidemiology.

    PubMed

    Ramazanzadeh, Rashid; McNerney, Ruth

    2007-08-15

    Molecular epidemiology is the using of molecular techniques to study bacterial distribution in human populations. Recently molecular epidemiologist benefit from several techniques such as Variable Number Tandem Repeat (VNTR) typing method to typing bacterial strains. Variable Number Tandem Repeat (VNTR) typing is a tool for genotyping and provides data in a simple and numeric format based on the number of repetitive sequences. VNTR for first time identified in M. tuberculosis as Mycobacterial Interspersed Repeat Units (MIRUs). General terms of VNTR have now been reported in Bacillus anthracis, Legionella pneumophila, Pseudomonas aeruginosa, Salmonella enterica and Escherichia coli O157.

  17. Stress Degradation Studies on Varenicline Tartrate and Development of a Validated Stability-Indicating HPLC Method

    PubMed Central

    Pujeri, Sudhakar S.; Khader, Addagadde M. A.; Seetharamappa, Jaldappagari

    2012-01-01

    A simple, rapid and stability-indicating reversed-phase liquid chromatographic method was developed for the assay of varenicline tartrate (VRT) in the presence of its degradation products generated from forced decomposition studies. The HPLC separation was achieved on a C18 Inertsil column (250 mm × 4.6 mm i.d. particle size is 5 μm) employing a mobile phase consisting of ammonium acetate buffer containing trifluoroacetic acid (0.02M; pH 4) and acetonitrile in gradient program mode with a flow rate of 1.0 mL min−1. The UV detector was operated at 237 nm while column temperature was maintained at 40 °C. The developed method was validated as per ICH guidelines with respect to specificity, linearity, precision, accuracy, robustness and limit of quantification. The method was found to be simple, specific, precise and accurate. Selectivity of the proposed method was validated by subjecting the stock solution of VRT to acidic, basic, photolysis, oxidative and thermal degradation. The calibration curve was found to be linear in the concentration range of 0.1–192 μg mL−1 (R2 = 0.9994). The peaks of degradation products did not interfere with that of pure VRT. The utility of the developed method was examined by analyzing the tablets containing VRT. The results of analysis were subjected to statistical analysis. PMID:22396908

  18. Tandem catalysis: a new approach to polymers.

    PubMed

    Robert, Carine; Thomas, Christophe M

    2013-12-21

    The creation of polymers by tandem catalysis represents an exciting frontier in materials science. Tandem catalysis is one of the strategies used by Nature for building macromolecules. Living organisms generally synthesize macromolecules by in vivo enzyme-catalyzed chain growth polymerization reactions using activated monomers that have been formed within cells during complex metabolic processes. However, these biological processes rely on highly complex biocatalysts, thus limiting their industrial applications. In order to obtain polymers by tandem catalysis, homogeneous and enzyme catalysts have played a leading role in the last two decades. In the following feature article, we will describe selected published efforts to achieve these research goals.

  19. Method of restoring degraded solar cells

    DOEpatents

    Staebler, David L.

    1983-01-01

    Amorphous silicon solar cells have been shown to have efficiencies which degrade as a result of long exposure to light. Annealing such cells in air at a temperature of about 200.degree. C. for at least 30 minutes restores their efficiency.

  20. Peptide Analysis Using Tandem Mass Spectrometry

    DTIC Science & Technology

    1989-06-01

    to give pyroglutamic acid during storage, eliminating ammonia. It is almost absent in the spectrum of a freshly-prepared sample and is not seen in...USING TANDEM MASS SPECTROMETRY INTRODUCTION S The objective of the project was to determine the complete amino acid sequence of the large polypeptide...Ubiquitin by use of fast atom bombardment (FAB) ionization and tandem mass spectrometry. The peptide containing 76 amino acid residues was available

  1. METHOD 535: MEASUREMENT OF CHLOROACETANILIDE AND CHLOROACETAMIDE HERBICIDE DEGRADATES IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    EPA Science Inventory

    Over the past several years, ethanesulfonic acid (ESA) and oxanilic acid (OA) degradation products of acetanilide/acetamide herbicides have been found in U.S. ground waters and surface waters. The substitution of the sulfonic acid or the carbonic acid for the chlorine atom great...

  2. Microbial Degradation of Forensic Samples of Biological Origin: Potential Threat to Human DNA Typing.

    PubMed

    Dash, Hirak Ranjan; Das, Surajit

    2018-02-01

    Forensic biology is a sub-discipline of biological science with an amalgam of other branches of science used in the criminal justice system. Any nucleated cell/tissue harbouring DNA, either live or dead, can be used as forensic exhibits, a source of investigation through DNA typing. These biological materials of human origin are rich source of proteins, carbohydrates, lipids, trace elements as well as water and, thus, provide a virtuous milieu for the growth of microbes. The obstinate microbial growth augments the degradation process and is amplified with the passage of time and improper storage of the biological materials. Degradation of these biological materials carriages a huge challenge in the downstream processes of forensic DNA typing technique, such as short tandem repeats (STR) DNA typing. Microbial degradation yields improper or no PCR amplification, heterozygous peak imbalance, DNA contamination from non-human sources, degradation of DNA by microbial by-products, etc. Consequently, the most precise STR DNA typing technique is nullified and definite opinion can be hardly given with degraded forensic exhibits. Thus, suitable precautionary measures should be taken for proper storage and processing of the biological exhibits to minimize their decaying process by micro-organisms.

  3. Method of restoring degraded solar cells

    DOEpatents

    Staebler, D.L.

    1983-02-01

    Amorphous silicon solar cells have been shown to have efficiencies which degrade as a result of long exposure to light. Annealing such cells in air at a temperature of about 200 C for at least 30 minutes restores their efficiency. 2 figs.

  4. A degradation-based sorting method for lithium-ion battery reuse.

    PubMed

    Chen, Hao; Shen, Julia

    2017-01-01

    In a world where millions of people are dependent on batteries to provide them with convenient and portable energy, battery recycling is of the utmost importance. In this paper, we developed a new method to sort 18650 Lithium-ion batteries in large quantities and in real time for harvesting used cells with enough capacity for battery reuse. Internal resistance and capacity tests were conducted as a basis for comparison with a novel degradation-based method based on X-ray radiographic scanning and digital image contrast computation. The test results indicate that the sorting accuracy of the test cells is about 79% and the execution time of our algorithm is at a level of 200 milliseconds, making our method a potential real-time solution for reusing the remaining capacity in good used cells.

  5. A degradation-based sorting method for lithium-ion battery reuse

    PubMed Central

    Chen, Hao

    2017-01-01

    In a world where millions of people are dependent on batteries to provide them with convenient and portable energy, battery recycling is of the utmost importance. In this paper, we developed a new method to sort 18650 Lithium-ion batteries in large quantities and in real time for harvesting used cells with enough capacity for battery reuse. Internal resistance and capacity tests were conducted as a basis for comparison with a novel degradation-based method based on X-ray radiographic scanning and digital image contrast computation. The test results indicate that the sorting accuracy of the test cells is about 79% and the execution time of our algorithm is at a level of 200 milliseconds, making our method a potential real-time solution for reusing the remaining capacity in good used cells. PMID:29023485

  6. Rational design of alpha-helical tandem repeat proteins with closed architectures

    PubMed Central

    Doyle, Lindsey; Hallinan, Jazmine; Bolduc, Jill; Parmeggiani, Fabio; Baker, David; Stoddard, Barry L.; Bradley, Philip

    2015-01-01

    Tandem repeat proteins, which are formed by repetition of modular units of protein sequence and structure, play important biological roles as macromolecular binding and scaffolding domains, enzymes, and building blocks for the assembly of fibrous materials1,2. The modular nature of repeat proteins enables the rapid construction and diversification of extended binding surfaces by duplication and recombination of simple building blocks3,4. The overall architecture of tandem repeat protein structures – which is dictated by the internal geometry and local packing of the repeat building blocks – is highly diverse, ranging from extended, super-helical folds that bind peptide, DNA, and RNA partners5–9, to closed and compact conformations with internal cavities suitable for small molecule binding and catalysis10. Here we report the development and validation of computational methods for de novo design of tandem repeat protein architectures driven purely by geometric criteria defining the inter-repeat geometry, without reference to the sequences and structures of existing repeat protein families. We have applied these methods to design a series of closed alpha-solenoid11 repeat structures (alpha-toroids) in which the inter-repeat packing geometry is constrained so as to juxtapose the N- and C-termini; several of these designed structures have been validated by X-ray crystallography. Unlike previous approaches to tandem repeat protein engineering12–20, our design procedure does not rely on template sequence or structural information taken from natural repeat proteins and hence can produce structures unlike those seen in nature. As an example, we have successfully designed and validated closed alpha-solenoid repeats with a left-handed helical architecture that – to our knowledge – is not yet present in the protein structure database21. PMID:26675735

  7. An ultra-high pressure liquid chromatography-tandem mass spectrometry method for the quantification of teicoplanin in plasma of neonates.

    PubMed

    Begou, O; Kontou, A; Raikos, N; Sarafidis, K; Roilides, E; Papadoyannis, I N; Gika, H G

    2017-03-15

    The development and validation of an ultra-high pressure liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was performed with the aim to be applied for the quantification of plasma teicoplanin concentrations in neonates. Pharmacokinetic data of teicoplanin in the neonatal population is very limited, therefore, a sensitive and reliable method for the determination of all isoforms of teicoplanin applied in a low volume of sample is of real importance. Teicoplanin main components were extracted by a simple acetonitrile precipitation step and analysed on a C18 chromatographic column by a triple quadrupole MS with electrospray ionization. The method provides quantitative data over a linear range of 25-6400ng/mL with LOD 8.5ng/mL and LOQ 25ng/mL for total teicoplanin. The method was applied in plasma samples from neonates to support pharmacokinetic data and proved to be a reliable and fast method for the quantification of teicoplanin concentration levels in plasma of infants during therapy in Intensive Care Unit. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. TRedD—A database for tandem repeats over the edit distance

    PubMed Central

    Sokol, Dina; Atagun, Firat

    2010-01-01

    A ‘tandem repeat’ in DNA is a sequence of two or more contiguous, approximate copies of a pattern of nucleotides. Tandem repeats are common in the genomes of both eukaryotic and prokaryotic organisms. They are significant markers for human identity testing, disease diagnosis, sequence homology and population studies. In this article, we describe a new database, TRedD, which contains the tandem repeats found in the human genome. The database is publicly available online, and the software for locating the repeats is also freely available. The definition of tandem repeats used by TRedD is a new and innovative definition based upon the concept of ‘evolutive tandem repeats’. In addition, we have developed a tool, called TandemGraph, to graphically depict the repeats occurring in a sequence. This tool can be coupled with any repeat finding software, and it should greatly facilitate analysis of results. Database URL: http://tandem.sci.brooklyn.cuny.edu/ PMID:20624712

  9. Structural analysis of isomeric chondroitin sulfate oligosaccharides using regioselective 6-O-desulfation method and tandem mass spectrometry.

    PubMed

    Chen, Shu-Ting; Her, Guor-Rong

    2014-09-16

    A strategy based on a regioselective 6-O-desulfation reaction and negative ion electrospray ionization tandem mass spectrometry (ESI-MS(n)) was developed for the structural delineation of isomeric chondroitin sulfate oligosaccharides. Product ions resulting from the glycosidic cleavage provided information about the number of sulfate groups in each sugar residue. After the regioselective 6-O-desulfation reaction, the number of sulfate groups on each residue was obtained using a tandem mass spectrometry analysis of the reaction product. The sulfation pattern could be obtained based on the product ions of analytes before and after the desulfation reaction. The strategy was demonstrated using a series of tetrasaccharides prepared from shark cartilage chondroitin sulfate D. Among the 12 identified tetrasaccharides, six structures had not been reported before. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. PTGBase: an integrated database to study tandem duplicated genes in plants.

    PubMed

    Yu, Jingyin; Ke, Tao; Tehrim, Sadia; Sun, Fengming; Liao, Boshou; Hua, Wei

    2015-01-01

    Tandem duplication is a wide-spread phenomenon in plant genomes and plays significant roles in evolution and adaptation to changing environments. Tandem duplicated genes related to certain functions will lead to the expansion of gene families and bring increase of gene dosage in the form of gene cluster arrays. Many tandem duplication events have been studied in plant genomes; yet, there is a surprising shortage of efforts to systematically present the integration of large amounts of information about publicly deposited tandem duplicated gene data across the plant kingdom. To address this shortcoming, we developed the first plant tandem duplicated genes database, PTGBase. It delivers the most comprehensive resource available to date, spanning 39 plant genomes, including model species and newly sequenced species alike. Across these genomes, 54 130 tandem duplicated gene clusters (129 652 genes) are presented in the database. Each tandem array, as well as its member genes, is characterized in complete detail. Tandem duplicated genes in PTGBase can be explored through browsing or searching by identifiers or keywords of functional annotation and sequence similarity. Users can download tandem duplicated gene arrays easily to any scale, up to the complete annotation data set for an entire plant genome. PTGBase will be updated regularly with newly sequenced plant species as they become available. © The Author(s) 2015. Published by Oxford University Press.

  11. Effects of different artificial ageing methods on the degradation of adhesive-dentine interfaces.

    PubMed

    Deng, Donglai; Yang, Hongye; Guo, Jingmei; Chen, Xiaohui; Zhang, Weiping; Huang, Cui

    2014-12-01

    To compare the effects of four commonly used artificial ageing methods (water storage, thermocycling, NaOCl storage and pH cycling) on the degradation of adhesive-dentine interfaces. Fifty molars were sectioned parallel to the occlusal plane, polished and randomly divided into two adhesive groups: An etch-and-rinse adhesive Adper SingleBond 2 and a self-etch adhesive G-Bond. After the composite built up, the specimens from each adhesive group were sectioned into beams, which were then assigned to one of the following groups: Group 1 (control), 24h of water storage; Group 2, 6 months of water storage; Group 3, 10,000 runs of thermocycling; Group 4, 1h of 10% NaOCl storage; and Group 5, 15 runs of pH cycling. The microtensile bond strengths were then tested. The failure modes were classified with a stereomicroscope and representative interface was analyzed with a field-emission scanning electron microscopy (FESEM). Nanoleakage expression was evaluated through FESEM in the backscattered mode. The four artificial ageing methods decreased the bonding strength to nearly 50% and increased the nanoleakage expression of both adhesive systems compared with the control treatment. Adhesive failures were the predominant fracture modes in all groups. However, differences in detailed morphology were observed among the different groups. Water storage, thermocycling, NaOCl storage and pH cycling could obtain similar degradation effectiveness through appropriate parameter selection. Each in vitro artificial ageing method had its own mechanisms, characteristics and application scope for degrading the adhesive-dentin interfaces. Water storage is simple, low-cost but time-consuming; thermocycling lacks of a standard agreement; NaOCl storage is time-saving but mainly degrades the organic phase; pH cycling can resemble cariogenic condition but needs further studies. Researchers focusing on bonding durability studies should be deliberate in selecting an appropriate ageing model based on

  12. Enantioselective supercritical fluid chromatography-tandem mass spectrometry method for simultaneous estimation of risperidone and its 9-hydroxyl metabolites in rat plasma.

    PubMed

    Prasad, Thatipamula R; Joseph, Siji; Kole, Prashant; Kumar, Anoop; Subramanian, Murali; Rajagopalan, Sudha; Kr, Prabhakar

    2017-11-01

    Objective of the current work was to develop a 'green chemistry' compliant selective and sensitive supercritical fluid chromatography-tandem mass spectrometry method for simultaneous estimation of risperidone (RIS) and its chiral metabolites in rat plasma. Methodology & results: Agilent 1260 Infinity analytical supercritical fluid chromatography system resolved RIS and its chiral metabolites within runtime of 6 min using a gradient chromatography method. Using a simple protein precipitation sample preparation followed by mass spectrometric detection achieved a sensitivity of 0.92 nM (lower limit of quantification). With linearity over four log units (0.91-7500 nM), the method was found to be selective, accurate, precise and robust. The method was validated and was successfully applied for simultaneous estimation of RIS and 9-hydroxyrisperidone metabolites (R & S individually) after intravenous and per oral administration to rats.

  13. Stability indicating spectrophotometric and spectrodensitometric methods for the determination of diatrizoate sodium in presence of its degradation product

    NASA Astrophysics Data System (ADS)

    Abd El-Rahman, Mohamed K.; Riad, Safaa M.; Abdel Gawad, Sherif A.; Fawaz, Esraa M.; Shehata, Mostafa A.

    2015-02-01

    Three sensitive, selective, and precise stability indicating methods for the determination of the X-ray contrast agent, diatrizoate sodium (DTA), in the presence of its acidic degradation product (highly cytotoxic 3,5 diamino metabolite) and in pharmaceutical formulation were developed and validated. The first method is a first derivative (D1) spectrophotometric one, which allows the determination of DTA in the presence of its degradate at 231.2 nm (corresponding to zero crossing of the degradate) over a concentration range of 2-24 μg/mL with mean percentage recovery 99.95 ± 0.97%. The second method is the first derivative of the ratio spectra (DD1) by measuring the peak amplitude at 227 nm over the same concentration range as D1 spectrophotometric method, with mean percentage recovery 99.99 ± 1.15%. The third method is a TLC-densitometric one, where DTA was separated from its degradate on silica gel plates using chloroform:methanol:ammonium hydroxide (20:10:2 by volume) as a developing system. This method depends on quantitative densitometric evaluation of thin layer chromatogram of DTA at 238 nm over a concentration range of 4-20 μg/spot, with mean percentage recovery 99.88 ± 0.89%. The selectivity of the proposed methods was tested using laboratory-prepared mixtures. The proposed methods have been successfully applied to the analysis of DTA in pharmaceutical dosage forms without interference from other dosage form additives. The results were statistically compared with the official US pharmacopeial method. No significant difference for either accuracy or precision was observed.

  14. Hybrid Tandem Solar Cells | Photovoltaic Research | NREL

    Science.gov Websites

    Hybrid Tandem Solar Cells Hybrid Tandem Solar Cells To achieve aggressive cost reductions in photovoltaics (PV) beyond the 6¢/kWh SunShot Initiative 2020 goal, module efficiency must be increased beyond on a silicon platform and that aim to provide viable prototypes for commercialization. PV Research

  15. Monolithic Parallel Tandem Organic Photovoltaic Cell with Transparent Carbon Nanotube Interlayer

    NASA Technical Reports Server (NTRS)

    Tanaka, S.; Mielczarek, K.; Ovalle-Robles, R.; Wang, B.; Hsu, D.; Zakhidov, A. A.

    2009-01-01

    We demonstrate an organic photovoltaic cell with a monolithic tandem structure in parallel connection. Transparent multiwalled carbon nanotube sheets are used as an interlayer anode electrode for this parallel tandem. The characteristics of front and back cells are measured independently. The short circuit current density of the parallel tandem cell is larger than the currents of each individual cell. The wavelength dependence of photocurrent for the parallel tandem cell shows the superposition spectrum of the two spectral sensitivities of the front and back cells. The monolithic three-electrode photovoltaic cell indeed operates as a parallel tandem with improved efficiency.

  16. A liquid chromatography - tandem mass spectrometry method to measure a selected panel of uremic retention solutes derived from endogenous and colonic microbial metabolism.

    PubMed

    de Loor, Henriette; Poesen, Ruben; De Leger, Wout; Dehaen, Wim; Augustijns, Patrick; Evenepoel, Pieter; Meijers, Björn

    2016-09-14

    Chronic kidney disease (CKD) is associated with an increased risk of mortality and cardiovascular disease, which is, at least partly, mediated by the accumulation of so-called uremic retention solutes. Although there has been an increasing interest in the behavior of these solutes, derived from both the endogenous and colonic microbial metabolism, methods to simultaneously and accurately measure a broad panel of relevant uremic retention solutes remain scarce. We developed a highly sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. A high throughput sample preparation was used with extraction of analytes from 50 μl serum using Ostro plate technology. For most solutes, stable isotopes labelled metabolites were used as internal standards. Chromatography was achieved using an Acquity UPLC CSH Fluoro Phenyl column. The total run time was 8 min, the mobile phase was a gradient of 0.1% formic acid in Milli-Q water and pure methanol at a flow rate of 0.5 ml min(-1). Detection was performed using a tandem mass spectrometer with alternated positive and negative electrospray ionization. Calibration curves were linear for all solutes. Precision was assessed according to the NCCLS EP5-T guideline, being below 15% for all metabolites. Mean recoveries were between 83 and 104% for all metabolites. The validated method was successfully applied in a cohort of 488 patients with CKD. We developed and validated a sensitive and robust UPLC-MS/MS method for quantification of 15 uremic retention solutes derived from endogenous and colonic microbial metabolism. This method allows for studying the behavior and relevance of these solutes in patients with CKD. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Stability-indicating UPLC method for determination of Valsartan and their degradation products in active pharmaceutical ingredient and pharmaceutical dosage forms.

    PubMed

    Krishnaiah, Ch; Reddy, A Raghupathi; Kumar, Ramesh; Mukkanti, K

    2010-11-02

    A simple, precise, accurate stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the quantitative determination of purity of Valsartan drug substance and drug products in bulk samples and pharmaceutical dosage forms in the presence of its impurities and degradation products. The method was developed using Waters Aquity BEH C18 (100 mm x 2.1 mm, 1.7 microm) column with mobile phase containing a gradient mixture of solvents A and B. The eluted compounds were monitored at 225 nm, the run time was within 9.5 min, which Valsartan and its seven impurities were well separated. Valsartan was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Valsartan was found to degrade significantly in acid and oxidative stress conditions and stable in base, hydrolytic and photolytic degradation conditions. The degradation products were well resolved from main peak and its impurities, proving the stability-indicating power of the method. The developed method was validated as per international conference on harmonization (ICH) guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of Valsartan in pharmaceutical dosage forms.

  18. Rapid screening of N-oxides of chemical warfare agents degradation products by ESI-tandem mass spectrometry.

    PubMed

    Sridhar, L; Karthikraj, R; Lakshmi, V V S; Raju, N Prasada; Prabhakar, S

    2014-08-01

    Rapid detection and identification of chemical warfare agents and related precursors/degradation products in various environmental matrices is of paramount importance for verification of standards set by the chemical weapons convention (CWC). Nitrogen mustards, N,N-dialkylaminoethyl-2-chlorides, N,N-dialkylaminoethanols, N-alkyldiethanolamines, and triethanolamine, which are listed CWC scheduled chemicals, are prone to undergo N-oxidation in environmental matrices or during decontamination process. Thus, screening of the oxidized products of these compounds is also an important task in the verification process because the presence of these products reveals alleged use of nitrogen mustards or precursors of VX compounds. The N-oxides of aminoethanols and aminoethylchlorides easily produce [M + H](+) ions under electrospray ionization conditions, and their collision-induced dissociation spectra include a specific neutral loss of 48 u (OH + CH2OH) and 66 u (OH + CH2Cl), respectively. Based on this specific fragmentation, a rapid screening method was developed for screening of the N-oxides by applying neutral loss scan technique. The method was validated and the applicability of the method was demonstrated by analyzing positive and negative samples. The method was useful in the detection of N-oxides of aminoethanols and aminoethylchlorides in environmental matrices at trace levels (LOD, up to 500 ppb), even in the presence of complex masking agents, without the use of time-consuming sample preparation methods and chromatographic steps. This method is advantageous for the off-site verification program and also for participation in official proficiency tests conducted by the Organization for the Prohibition of Chemical Weapons (OPCW), the Netherlands. The structure of N-oxides can be confirmed by the MS/MS experiments on the detected peaks. A liquid chromatography-mass spectrometry (LC-MS) method was developed for the separation of isomeric N-oxides of aminoethanols and

  19. Crux: Rapid Open Source Protein Tandem Mass Spectrometry Analysis

    PubMed Central

    2015-01-01

    Efficiently and accurately analyzing big protein tandem mass spectrometry data sets requires robust software that incorporates state-of-the-art computational, machine learning, and statistical methods. The Crux mass spectrometry analysis software toolkit (http://cruxtoolkit.sourceforge.net) is an open source project that aims to provide users with a cross-platform suite of analysis tools for interpreting protein mass spectrometry data. PMID:25182276

  20. [Multi-residue method for screening of pesticides in crops by liquid chromatography with tandem mass spectrometry].

    PubMed

    Tanizawa, Haruna; Shima, Mikie; Ikehara, Chieko; Kobata, Masakazu; Sato, Motoaki

    2005-10-01

    A simple and rapid method was developed for the screening of 82 pesticides/metabolites in a wide variety of crops, using solid-phase extraction and liquid chromatography with tandem mass spectrometry (LC/MS/MS). After extraction with methanol, the filtered extracts were made up to 100 mL and a 2 mL aliquot was subjected to solid-phase extraction. Co-extractives were removed with a C18 mini-column, while pesticides were retained on 3 kinds of mini-columns (HLB, SAX, activated carbon), and then eluted with acetonitrile. Analysis was performed by LC/MS/MS, and MS acquisition parameters were established in positive and negative ESI modes. The utility of the method was demonstrated by the analysis of 6 crops (carrot, cabbage, onion, spinach, lemon, brown rice) and one mixed vegetable juice. Of 82 compounds tested, 75 in carrot and 62 in lemon were obtained with recoveries ranging from 70-120%. For all samples tested, 75 compounds could be obtained with recoveries of over 50%, and the detection limits of most compounds were lower than 0.01 microg/g. This method provides acceptable performance for analysis of these 75 compounds. Further, by using aliquots of the extracts with small-scale mini-columns, purified samples could be obtained. This proposed method with small matrix effects, is effective and suitable for screening of multiple residual pesticides by using LC/MS/MS.

  1. Inverted Three-Junction Tandem Thermophotovoltaic Modules

    NASA Technical Reports Server (NTRS)

    Wojtczuk, Steven

    2012-01-01

    An InGaAs-based three-junction (3J) tandem thermophotovoltaic (TPV) cell has been investigated to utilize more of the blackbody spectrum (from a 1,100 C general purpose heat source GPHS) efficiently. The tandem consists of three vertically stacked subcells, a 0.74-eV InGaAs cell, a 0.6- eV InGaAs cell, and a 0.55-eV InGaAs cell, as well as two interconnecting tunnel junctions. A greater than 20% TPV system efficiency was achieved by another group with a 1,040 C blackbody using a single-bandgap 0.6- eV InGaAs cell MIM (monolithic interconnected module) (30 lateral junctions) that delivered about 12 V/30 or 0.4 V/junction. It is expected that a three-bandgap tandem MIM will eventually have about 3 this voltage (1.15 V) and about half the current. A 4 A/cm2 would be generated by a single-bandgap 0.6-V InGaAs MIM, as opposed to the 2 A/cm2 available from the same spectrum when split among the three series-connected junctions in the tandem stack. This would then be about a 50% increase (3xVoc, 0.5xIsc) in output power if the proposed tandem replaced the single- bandgap MIM. The advantage of the innovation, if successful, would be a 50% increase in power conversion efficiency from radioisotope heat sources using existing thermophotovoltaics. Up to 50% more power would be generated for radioisotope GPHS deep space missions. This type of InGaAs multijunction stack could be used with terrestrial concentrator solar cells to increase efficiency from 41 to 45% or more.

  2. Stability-indicating methods for the determination of racecadotril in the presence of its degradation products.

    PubMed

    Mohamed, Afaf O; Fouad, Manal M; Hasan, Mona M; Abdel Razeq, Sawsan A; Elsherif, Zeinab A

    2009-12-01

    Three stability-indicating methods were developed for the determination of racecadotril (RCT) in the presence of its alkaline degradation products. The first was an HPLC method in which efficient chromatographic separation was achieved on a C18 analytical column and a mobile phase of acetonitrile-methanol-water-acetic acid (52:28:20:0.1, v/v/v/v). Linearity was obtained in the range of 4-40 microg/mL with mean accuracy of 99.5 +/- 0.88%. The second method was a densitometric evaluation of thin-layer chromatograms of the drug using a mobile phase of isopropanol-ammonia (33%)-n-hexane (9:0.5:20, v/v/v). The chromatograms were scanned at 232 nm, a wavelength at which RCT can be readily separated from its degradation products and determined in the range of 2-20 microg per spot with mean accuracy of 99.5 +/- 0.56%. The third method is based on the use of first-derivative spectrophotometry (D1) at 240 nm, and the drug was determined in the range of 5-40 microg/mL with mean accuracy of 99.2 +/- 1.02%. The three methods provided satisfactory recovery of the intact drug (100.8 +/- 0.82, 100.4 +/- 0.55, and 99.9 +/- 0.72%, respectively) in the presence of up to 90% of its degradation products. Determination was also successful when analyzing RCT in a formulation in the form of acetorphan packets. Results were statistically analyzed and found to be in accordance with those given by a reported method.

  3. Effect of different sulfadimidine addition methods on its degradation behaviour in swine manure.

    PubMed

    Ren, Tian-Tian; Li, Xiao-Yang; Wang, Yan; Zou, Yong-De; Liao, Xin-Di; Liang, Juan-Boo; Wu, Yin-Bao

    2017-03-01

    Sulfadimidine (SM2) is commonly used in the swine industry and enters the environment via faeces. In recent years, advances in the ecotoxicology of SM2 have become a popular research interest with two common research methods including swine manure collection from swine fed with a diet containing SM2 and directly adding SM2. The purpose of this experiment was to compare SM2 degradation behaviour in pig manure with two different SM2 addition methods. The results showed that the degradation half-lives of SM2 in manure from SM2-fed swine treatment were 33.2 and 32.0 days at the initial addition level of SM2 at 32.1 and 64.3 mg/kg, respectively. This was significantly longer than that in manure directly adding SM2 treatment with the half-lives of 21.4 and 14.8 days. The metabolite of SM2 N 4 -acetyl-sulfamethazine occurred in manure from SM2-fed swine treatment but was not detected in directly adding SM2 treatment. The pH in manure from SM2-fed swine treatment was significantly lower than that in directly adding SM2 treatment, but the values of organic carbon, total nitrogen, and electrical conductivity in manure from SM2-fed swine treatment were significantly higher than those in manure directly adding SM2 treatment. Meanwhile, although the copy number of bacteria had no significant difference between two treatments, there was a significant difference in bacteria diversity. Results of the present study demonstrated that the presence of the metabolites, chemical property, and microbial diversity might be the reason for different SM2 degradation behaviours on different addition methods. Thus, the method using manure with SM2 collected from swine could obtain more accurate results for the ecotoxicological study of SM2.

  4. Interpreting the Need for Initial Support to Perform Tandem Stance Tests of Balance

    PubMed Central

    Brach, Jennifer S.; Perera, Subashan; Wert, David M.; VanSwearingen, Jessie M.; Studenski, Stephanie A.

    2012-01-01

    Background Geriatric rehabilitation reimbursement increasingly requires documented deficits on standardized measures. Tandem stance performance can characterize balance, but protocols are not standardized. Objective The purpose of this study was to explore the impact of: (1) initial support to stabilize in position and (2) maximum hold time on tandem stance tests of balance in older adults. Design A cross-sectional secondary analysis of observational cohort data was conducted. Methods One hundred seventeen community-dwelling older adults (71% female, 12% black) were assigned to 1 of 3 groups based on the need for initial support to perform tandem stance: (1) unable even with support, (2) able only with support, and (3) able without support. The able without support group was further stratified on hold time in seconds: (1) <10 (low), (2) 10 to 29, (medium), and (3) 30 (high). Groups were compared on primary outcomes (gait speed, Timed “Up & Go” Test performance, and balance confidence) using analysis of variance. Results Twelve participants were unable to perform tandem stance, 14 performed tandem stance only with support, and 91 performed tandem stance without support. Compared with the able without support group, the able with support group had statistically or clinically worse performance and balance confidence. No significant differences were found between the able with support group and the unable even with support group on these same measures. Extending the hold time to 30 seconds in a protocol without initial support eliminated ceiling effects for 16% of the study sample. Limitations Small comparison groups, use of a secondary analysis, and lack of generalizability of results were limitations of the study. Conclusions Requiring initial support to stabilize in tandem stance appears to reflect meaningful deficits in balance-related mobility measures, so failing to consider support may inflate balance estimates and confound hold time comparisons

  5. Performance of a tandem-rotor/tandem-stator conical-flow compressor designed for a pressure ratio of 3

    NASA Technical Reports Server (NTRS)

    Wood, J. R.; Owen, A. K.; Schumann, L. F.

    1982-01-01

    A conical-flow compressor stage with a large radius change through the rotor was tested at three values of rotor tip clearance. The stage had a tandem rotor and a tandem stator. Peak efficiency at design speed was 0.774 at a pressure ratio of 2.613. The rotor was tested without the stator, and detailed survey data were obtained for each rotor blade row. Overall peak rotor efficiency was 0.871 at a pressure ratio of 2.952.

  6. Robust PV Degradation Methodology and Application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jordan, Dirk; Deline, Christopher A; Kurtz, Sarah

    The degradation rate plays an important role in predicting and assessing the long-term energy generation of PV systems. Many methods have been proposed for extracting the degradation rate from operational data of PV systems, but most of the published approaches are susceptible to bias due to inverter clipping, module soiling, temporary outages, seasonality, and sensor degradation. In this manuscript, we propose a methodology for determining PV degradation leveraging available modeled clear-sky irradiance data rather than site sensor data, and a robust year-over-year (YOY) rate calculation. We show the method to provide reliable degradation rate estimates even in the case ofmore » sensor drift, data shifts, and soiling. Compared with alternate methods, we demonstrate that the proposed method delivers the lowest uncertainty in degradation rate estimates for a fleet of 486 PV systems.« less

  7. Robust PV Degradation Methodology and Application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jordan, Dirk C.; Deline, Chris; Kurtz, Sarah R.

    The degradation rate plays an important role in predicting and assessing the long-term energy generation of photovoltaics (PV) systems. Many methods have been proposed for extracting the degradation rate from operational data of PV systems, but most of the published approaches are susceptible to bias due to inverter clipping, module soiling, temporary outages, seasonality, and sensor degradation. In this paper, we propose a methodology for determining PV degradation leveraging available modeled clear-sky irradiance data rather than site sensor data, and a robust year-over-year rate calculation. We show the method to provide reliable degradation rate estimates even in the case ofmore » sensor drift, data shifts, and soiling. Compared with alternate methods, we demonstrate that the proposed method delivers the lowest uncertainty in degradation rate estimates for a fleet of 486 PV systems.« less

  8. Robust PV Degradation Methodology and Application

    DOE PAGES

    Jordan, Dirk C.; Deline, Chris; Kurtz, Sarah R.; ...

    2017-12-21

    The degradation rate plays an important role in predicting and assessing the long-term energy generation of photovoltaics (PV) systems. Many methods have been proposed for extracting the degradation rate from operational data of PV systems, but most of the published approaches are susceptible to bias due to inverter clipping, module soiling, temporary outages, seasonality, and sensor degradation. In this paper, we propose a methodology for determining PV degradation leveraging available modeled clear-sky irradiance data rather than site sensor data, and a robust year-over-year rate calculation. We show the method to provide reliable degradation rate estimates even in the case ofmore » sensor drift, data shifts, and soiling. Compared with alternate methods, we demonstrate that the proposed method delivers the lowest uncertainty in degradation rate estimates for a fleet of 486 PV systems.« less

  9. Recovering of images degraded by atmosphere

    NASA Astrophysics Data System (ADS)

    Lin, Guang; Feng, Huajun; Xu, Zhihai; Li, Qi; Chen, Yueting

    2017-08-01

    Remote sensing images are seriously degraded by multiple scattering and bad weather. Through the analysis of the radiative transfer procedure in atmosphere, an image atmospheric degradation model considering the influence of atmospheric absorption multiple scattering and non-uniform distribution is proposed in this paper. Based on the proposed model, a novel recovering method is presented to eliminate atmospheric degradation. Mean-shift image segmentation and block-wise deconvolution are used to reduce time cost, retaining a good result. The recovering results indicate that the proposed method can significantly remove atmospheric degradation and effectively improve contrast compared with other removal methods. The results also illustrate that our method is suitable for various degraded remote sensing, including images with large field of view (FOV), images taken in side-glance situations, image degraded by atmospheric non-uniform distribution and images with various forms of clouds.

  10. Validation of UV spectrophotometric methods for the determination of dothiepin hydrochloride in pharmaceutical dosage form and stress degradation studies

    NASA Astrophysics Data System (ADS)

    Abdulrahman, Sameer A. M.; Basavaiah, K.; Cijo, M. X.; Vinay, K. B.

    2012-11-01

    Spectrophotometric methods have been developed for the determination of dothiepin hydrochloride (DOTH) in both pure and tablet dosage form and their limits of detection and quantification have been evaluated. The methods are based on the measurement of the absorbance of a DOTH solution either in 0.1 N HCl at 229 nm (method A) or in methanol at 231 nm (method B). Beer's law is obeyed over a concentration range of 1-16 μg/ml DOTH for both methods. Molar absorptivity values are calculated to be 2.48 × 104 and 2.42 × 104 l/(mol × cm) with Sandell sensitivity values of 0.0134 and 0.0137 μg/cm2 for methods A and B, respectively. The degradation behavior of DOTH was investigated under different stress conditions such as acid hydrolysis, alkaline hydrolysis, water hydrolysis, oxidation, dry heat treatment, and UV-degradation. The drug undergoes significant degradation under oxidative conditions only.

  11. A tandem-based compact dual-energy gamma generator.

    PubMed

    Persaud, A; Kwan, J W; Leitner, M; Leung, K-N; Ludewigt, B; Tanaka, N; Waldron, W; Wilde, S; Antolak, A J; Morse, D H; Raber, T

    2010-02-01

    A dual-energy tandem-type gamma generator has been developed at E. O. Lawrence Berkeley National Laboratory and Sandia National Laboratories. The tandem accelerator geometry allows higher energy nuclear reactions to be reached, thereby allowing more flexible generation of MeV-energy gammas for active interrogation applications. Both positively charged ions and atoms of hydrogen are created from negative ions via a gas stripper. In this paper, we show first results of the working tandem-based gamma generator and that a gas stripper can be utilized in a compact source design. Preliminary results of monoenergetic gamma production are shown.

  12. Solar-to-Chemical Energy Conversion with Photoelectrochemical Tandem Cells.

    PubMed

    Sivula, Kevin

    2013-01-01

    Efficiently and inexpensively converting solar energy into chemical fuels is an important goal towards a sustainable energy economy. An integrated tandem cell approach could reasonably convert over 20% of the sun's energy directly into chemical fuels like H2 via water splitting. Many different systems have been investigated using various combinations of photovoltaic cells and photoelectrodes, but in order to be economically competitive with the production of H2 from fossil fuels, a practical water splitting tandem cell must optimize cost, longevity and performance. In this short review, the practical aspects of solar fuel production are considered from the perspective of a semiconductor-based tandem cell and the latest advances with a very promising technology - metal oxide photoelectrochemical tandem cells - are presented.

  13. TRAP: automated classification, quantification and annotation of tandemly repeated sequences.

    PubMed

    Sobreira, Tiago José P; Durham, Alan M; Gruber, Arthur

    2006-02-01

    TRAP, the Tandem Repeats Analysis Program, is a Perl program that provides a unified set of analyses for the selection, classification, quantification and automated annotation of tandemly repeated sequences. TRAP uses the results of the Tandem Repeats Finder program to perform a global analysis of the satellite content of DNA sequences, permitting researchers to easily assess the tandem repeat content for both individual sequences and whole genomes. The results can be generated in convenient formats such as HTML and comma-separated values. TRAP can also be used to automatically generate annotation data in the format of feature table and GFF files.

  14. Off-line solid phase extraction and liquid chromatography-tandem mass spectrometry method for the quantitation of brivaracetam acid metabolites: Method validation and application to in vitro metabolism assays.

    PubMed

    Bourgogne, Emmanuel; Culot, Benoit; Dell'Aiera, Sylvie; Chanteux, Hugues; Stockis, Armel; Nicolas, Jean-Marie

    2018-06-01

    Brivaracetam (BRV) is a new high affinity synaptic vesicle protein 2A ligand recently approved for adults with partial-onset seizures. As a support to in vitro metabolism assays, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method coupled to off-line solid phase extraction (SPE) was developed to quantify BRV acid metabolites, that is, BRV-AC (carboxylic derivative derived from BRV hydrolysis) and BRV-OHAC (corresponding to hydroxylated BRV-AC). The method was validated for various incubates (liver and kidney tissue homogenates and blood, all from humans) and applied to in vitro metabolism assays. The analytes were isolated from buffered samples using ISOLUTE C8 96-well SPE plates. Chromatographic separation was achieved on a Waters Atlantis T3 C18 analytical column (2.1 mm × 50 mm, 5 μm) with detection accomplished using a Waters Premier tandem mass spectrometer in positive ion electrospray and multiple reaction monitoring (MRM) mode. The standard curves, which ranged from 1.00 to 200 ng/mL for BRV-AC, BRV-OHAC, were fitted to a 1/x 2 weighted linear regression model. The intra-assay precision and inter-assay precision (expressed as coefficient of variation -%CV) were <8.5%, and the assay accuracy (deviation - %Dev) was within ±7.1% for the different matrices. This accurate, precise, and selective SPE/LC-MS/MS method has been successfully applied to in vitro assays aimed at characterizing the kinetics of BRV hydrolysis. BRV was found to be a better substrate for hydrolysis than its hydroxylated metabolite BRV-OH. BRV hydrolysis was detected in blood, liver and kidneys, demonstrating the broad distribution of the enzyme catalyzing the reaction. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Identification of Small Peptides in Human Cerebrospinal Fluid upon Amyloid-β Degradation.

    PubMed

    Mizuta, Naoki; Yanagida, Kanta; Kodama, Takashi; Tomonaga, Takeshi; Takami, Mako; Oyama, Hiroshi; Kudo, Takashi; Ikeda, Manabu; Takeda, Masatoshi; Tagami, Shinji; Okochi, Masayasu

    2017-01-01

    Amyloid-β (Aβ) degradation in brains of Alzheimer disease patients is a crucial focus for the clarification of disease pathogenesis. Nevertheless, the mechanisms underlying Aβ degradation in the human brain remain unclear. This study aimed to quantify the levels of small C-terminal Aβ fragments generated upon Aβ degradation in human cerebrospinal fluid (CSF). A fraction containing small peptides was isolated and purified from human CSF by high-pressure liquid chromatography. Degradation products of Aβ C termini were identified and measured by liquid chromatography-tandem mass spectrometry. The C-terminal fragments of Aβ in the conditioned medium of cultured cells transfected with the Swedish variant of βAPP (sw βAPP) were analyzed. These fragments in brains of PS1 I213T knock-in transgenic mice, overexpressing sw βAPP, were also analyzed. The peptide fragments GGVV and GVV, produced by the cleavage of Aβ40, were identified in human CSF as well as in the brains of the transgenic mice and in the conditioned medium of the cultured cells. Relative to Aβ40 levels, GGVV and GVV levels were 7.6 ± 0.81 and 1.5 ± 0.18%, respectively, in human CSF. Levels of the GGVV fragment did not increase by the introduction of genes encoding neprilysin and insulin-degrading enzyme to the cultured cells. Our results indicate that a substantial amount of Aβ40 in human brains is degraded via a neprilysin- or insulin-degrading enzyme-independent pathway. © 2017 S. Karger AG, Basel.

  16. A Novel and Rapid Method to Determine Doxycycline in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry

    PubMed Central

    Krishna, A. Chaitanya; Sathiyaraj, M.; Saravanan, R. S.; Chelladurai, R.; Vignesh, R.

    2012-01-01

    A simple, rapid, specific and sensitive liquid chromatography tandem mass spectrometric method has been developed and validated for the determination of doxycycline from the human plasma. Doxycycline is extracted from human plasma by solid phase extraction. Demeclocycline was used as an internal standard. Detection was performed at transitions of 444.800→428.200 for doxycycline and 464.700→448.100 for demeclocycline using mass spectrometry. Chromatographic separation of analyte and internal standard were carried out using a reverse phase C18, column at 0.500 ml/min flow. The assay of doxycycline is linear over the range of 0.055-7.612 μg/ml, with a precision <14.83%, regression coefficient (r2)=0.9961 and the limit of quantification in plasma for doxycycline was 0.055 μg/ml. Mean extraction recovery obtained was 95.55%. Samples are stable at room temperature for 6 h, processed samples were stable at least for 30.20 h and also stable at three freeze-thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in human plasma. PMID:23798780

  17. Bivariate versus multivariate smart spectrophotometric calibration methods for the simultaneous determination of a quaternary mixture of mosapride, pantoprazole and their degradation products.

    PubMed

    Hegazy, M A; Yehia, A M; Moustafa, A A

    2013-05-01

    The ability of bivariate and multivariate spectrophotometric methods was demonstrated in the resolution of a quaternary mixture of mosapride, pantoprazole and their degradation products. The bivariate calibrations include bivariate spectrophotometric method (BSM) and H-point standard addition method (HPSAM), which were able to determine the two drugs, simultaneously, but not in the presence of their degradation products, the results showed that simultaneous determinations could be performed in the concentration ranges of 5.0-50.0 microg/ml for mosapride and 10.0-40.0 microg/ml for pantoprazole by bivariate spectrophotometric method and in the concentration ranges of 5.0-45.0 microg/ml for both drugs by H-point standard addition method. Moreover, the applied multivariate calibration methods were able for the determination of mosapride, pantoprazole and their degradation products using concentration residuals augmented classical least squares (CRACLS) and partial least squares (PLS). The proposed multivariate methods were applied to 17 synthetic samples in the concentration ranges of 3.0-12.0 microg/ml mosapride, 8.0-32.0 microg/ml pantoprazole, 1.5-6.0 microg/ml mosapride degradation products and 2.0-8.0 microg/ml pantoprazole degradation products. The proposed bivariate and multivariate calibration methods were successfully applied to the determination of mosapride and pantoprazole in their pharmaceutical preparations.

  18. A surrogate analyte method to determine D-serine in mouse brain using liquid chromatography-tandem mass spectrometry.

    PubMed

    Kinoshita, Kohnosuke; Jingu, Shigeji; Yamaguchi, Jun-ichi

    2013-01-15

    A bioanalytical method for determining endogenous d-serine levels in the mouse brain using a surrogate analyte and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. [2,3,3-(2)H]D-serine and [(15)N]D-serine were used as a surrogate analyte and an internal standard, respectively. The surrogate analyte was spiked into brain homogenate to yield calibration standards and quality control (QC) samples. Both endogenous and surrogate analytes were extracted using protein precipitation followed by solid phase extraction. Enantiomeric separation was achieved on a chiral crown ether column with an analysis time of only 6 min without any derivatization. The column eluent was introduced into an electrospray interface of a triple-quadrupole mass spectrometer. The calibration range was 1.00 to 300 nmol/g, and the method showed acceptable accuracy and precision at all QC concentration levels from a validation point of view. In addition, the brain d-serine levels of normal mice determined using this method were the same as those obtained by a standard addition method, which is time-consuming but is often used for the accurate measurement of endogenous substances. Thus, this surrogate analyte method should be applicable to the measurement of d-serine levels as a potential biomarker for monitoring certain effects of drug candidates on the central nervous system. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Comparison and Evaluation of Clustering Algorithms for Tandem Mass Spectra.

    PubMed

    Rieder, Vera; Schork, Karin U; Kerschke, Laura; Blank-Landeshammer, Bernhard; Sickmann, Albert; Rahnenführer, Jörg

    2017-11-03

    In proteomics, liquid chromatography-tandem mass spectrometry (LC-MS/MS) is established for identifying peptides and proteins. Duplicated spectra, that is, multiple spectra of the same peptide, occur both in single MS/MS runs and in large spectral libraries. Clustering tandem mass spectra is used to find consensus spectra, with manifold applications. First, it speeds up database searches, as performed for instance by Mascot. Second, it helps to identify novel peptides across species. Third, it is used for quality control to detect wrongly annotated spectra. We compare different clustering algorithms based on the cosine distance between spectra. CAST, MS-Cluster, and PRIDE Cluster are popular algorithms to cluster tandem mass spectra. We add well-known algorithms for large data sets, hierarchical clustering, DBSCAN, and connected components of a graph, as well as the new method N-Cluster. All algorithms are evaluated on real data with varied parameter settings. Cluster results are compared with each other and with peptide annotations based on validation measures such as purity. Quality control, regarding the detection of wrongly (un)annotated spectra, is discussed for exemplary resulting clusters. N-Cluster proves to be highly competitive. All clustering results benefit from the so-called DISMS2 filter that integrates additional information, for example, on precursor mass.

  20. InP/Ga0.47In0.53As monolithic, two-junction, three-terminal tandem solar cells

    NASA Technical Reports Server (NTRS)

    Wanlaas, M. W.; Gessert, T. A.; Horner, G. S.; Emery, K. A.; Coutts, T. J.

    1991-01-01

    The work presented has focussed on increasing the efficiency of InP-based solar cells through the development of a high-performance InP/Ga(0.47)In(0.53)As two-junction, three-terminal monolithic tandem cell. Such a tandem is particularly suited to space applications where a radiation-hard top cell (i.e., InP) is required. Furthermore, the InP/Ga(0.47)In(0.53)As materials system is lattice matched and offers a top cell/bottom cell bandgap differential (0.60 eV at 300 K) suitable for high tandem cell efficiencies under AMO illumination. A three-terminal configuration was chosen since it allows for independent power collection from each subcell in the monolithic stack, thus minimizing the adverse impact of radiation damage on the overall tandem efficiency. Realistic computer modeling calculations predict an efficiency boost of 7 to 11 percent from the Ga(0.47)In(0.53)As bottom cell under AMO illumination (25 C) for concentration ratios in the 1 to 1000 range. Thus, practical AMO efficiencies of 25 to 32 percent appear possible with the InP/Ga(0.47)In(0.53)As tandem cell. Prototype n/p/n InP/Ga(0.47)In(0.53)As monolithic tandem cells were fabricated and tested successfully. Using an aperture to define the illuminated areas, efficiency measurements performed on a non-optimized device under standard global illumination conditions (25 C) with no antireflection coating (ARC) give 12.2 percent for the InP top cell and 3.2 percent for the Ga(0.47)In(0.53)As bottom cell, yielding an overall tandem efficiency of 15.4 percent. With an ARC, the tandem efficiency could reach approximately 22 percent global and approximately 20 percent AMO. Additional details regarding the performance of individual InP and Ga(0.47)In(0.53)As component cells, fabrication and operation of complete tandem cells and methods for improving the tandem cell performance, are also discussed.

  1. Production of low-molecular weight soluble yeast β-glucan by an acid degradation method.

    PubMed

    Ishimoto, Yuina; Ishibashi, Ken-Ichi; Yamanaka, Daisuke; Adachi, Yoshiyuki; Kanzaki, Ken; Iwakura, Yoichiro; Ohno, Naohito

    2018-02-01

    β-glucan is widely distributed in nature as water soluble and insoluble forms. Both forms of β-glucan are utilized in several fields, especially for functional foods. Yeast β-glucan is a medically important insoluble particle. Solubilization of yeast β-glucan may be valuable for improving functional foods and in medicinal industries. In the present study, we applied an acid degradation method to solubilize yeast β-glucan and found that β-glucan was effectively solubilized to low-molecular weight β-glucans by 45% sulfuric acid treatment at 20°C. The acid-degraded soluble yeast β-glucan (ad-sBBG) was further fractionated into a higher-molecular weight fraction (ad-sBBG-high) and a lower-molecular weight fraction (ad-sBBG-low). Since ad-sBBG-high contained mannan, while ad-sBBG-low contained it only scarcely, it was possible to prepare low-molecular weight soluble β-glucan with higher purity. In addition, ad-sBBG-low bound to dectin-1, which is an innate immunity receptor of β-glucan, and showed antagonistic activity against reactive oxygen production and cytokine synthesis by macrophages. Thus, this acid degradation method is an important procedure for generating immune-modulating, low-molecular weight, soluble yeast β-glucan. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Degradation of Tetracycline with BiFeO3 Prepared by a Simple Hydrothermal Method

    PubMed Central

    Xue, Zhehua; Wang, Ting; Chen, Bingdi; Malkoske, Tyler; Yu, Shuili; Tang, Yulin

    2015-01-01

    BiFeO3 particles (BFO) were prepared by a simple hydrothermal method and characterized. BFO was pure, with a wide particle size distribution, and was visible light responsive. Tetracycline was chosen as the model pollutant in this study. The pH value was an important factor influencing the degradation efficiency. The total organic carbon (TOC) measurement was emphasized as a potential standard to evaluate the visible light photocatalytic degradation efficiency. The photo-Fenton process showed much better degradation efficiency and a wider pH adaptive range than photocatalysis or the Fenton process solely. The optimal residual TOC concentrations of the photocatalysis, Fenton and photo-Fenton processes were 81%, 65% and 21%, while the rate constants of the three processes under the same condition where the best residual TOC was acquired were 9.7 × 10−3, 3.2 × 10−2 and 1.5 × 10−1 min−1, respectively. BFO was demonstrated to have excellent stability and reusability. A comparison among different reported advanced oxidation processes removing tetracycline (TC) was also made. Our findings showed that the photo-Fenton process had good potential for antibiotic-containing waste water treatment. It provides a new method to deal with antibiotic pollution. PMID:28793568

  3. Application of the method of temporal moments to interpret solute transport with sorption and degradation

    NASA Astrophysics Data System (ADS)

    Pang, Liping; Goltz, Mark; Close, Murray

    2003-01-01

    In this note, we applied the temporal moment solutions of [Das and Kluitenberg, 1996. Soil Sci. Am. J. 60, 1724] for one-dimensional advective-dispersive solute transport with linear equilibrium sorption and first-order degradation for time pulse sources to analyse soil column experimental data. Unlike most other moment solutions, these solutions consider the interplay of degradation and sorption. This permits estimation of a first-order degradation rate constant using the zeroth moment of column breakthrough data, as well as estimation of the retardation factor or sorption distribution coefficient of a degrading solute using the first moment. The method of temporal moment (MOM) formulae was applied to analyse breakthrough data from a laboratory column study of atrazine, hexazinone and rhodamine WT transport in volcanic pumice sand, as well as experimental data from the literature. Transport and degradation parameters obtained using the MOM were compared to parameters obtained by fitting breakthrough data from an advective-dispersive transport model with equilibrium sorption and first-order degradation, using the nonlinear least-square curve-fitting program CXTFIT. The results derived from using the literature data were also compared with estimates reported in the literature using different equilibrium models. The good agreement suggests that the MOM could provide an additional useful means of parameter estimation for transport involving equilibrium sorption and first-order degradation. We found that the MOM fitted breakthrough curves with tailing better than curve fitting. However, the MOM analysis requires complete breakthrough curves and relatively frequent data collection to ensure the accuracy of the moments obtained from the breakthrough data.

  4. Flexible organic tandem solar modules: a story of up-scaling

    NASA Astrophysics Data System (ADS)

    Spyropoulos, George D.; Kubis, Peter; Li, Ning; Lucera, Luca; Salvador, Michael; Baran, Derya; Machui, Florian; Ameri, Tayebeh; Voigt, Monika M.; Brabec, Christoph J.

    2014-10-01

    The competition in the field of solar energy between Organic Photovoltaics (OPVs) and several Inorganic Photovoltaic technologies is continuously increasing to reach the ultimate purpose of energy supply from inexpensive and easily manufactured solar cell units. Solution-processed printing techniques on flexible substrates attach a tremendous opportunity to the OPVs for the accomplishment of low-cost and large area applications. Furthermore, tandem architectures came to boost up even more OPVs by increasing the photon-harvesting properties of the device. In this work, we demonstrate the road of realizing flexible organic tandem solar modules constructed by a fully roll-to-roll compatible processing. The modules exhibit an efficiency of 5.4% with geometrical fill factors beyond 80% and minimized interconnection-resistance losses. The processing involves low temperature (<70 °C), coating methods compatible with slot die coating and high speed and precision laser patterning.

  5. An efficient fermentation method for the degradation of cyanogenic glycosides in flaxseed.

    PubMed

    Wu, C-F; Xu, X-M; Huang, S-H; Deng, M-C; Feng, A-J; Peng, J; Yuan, J-P; Wang, J-H

    2012-01-01

    Recently, flaxseed has become increasingly popular in the health food market because it contains a considerable amount of specific beneficial nutrients such as lignans and omega-3 fatty acids. However, the presence of cyanogenic glycosides (CGs) in flaxseed severely limits the exploitation of its health benefits and nutritive value. We, therefore, developed an effective fermentation method, optimised by response surface methodology (RSM), for degrading CGs with an enzymatic preparation that includes 12.5% β-glucosidase and 8.9% cyanide hydratase. These optimised conditions resulted in a maximum CG degradation level of 99.3%, reducing the concentration of cyanide in the flaxseed power from 1.156 to 0.015 mg g(-1) after 48 h of fermentation. The avoidance of steam heat to evaporate hydrocyanic acid (HCN) results in lower energy consumption and no environmental pollution. In addition, the detoxified flaxseed retained the beneficial nutrients, lignans and fatty acids at the same level as untreated flaxseed, and this method could provide a new means of removing CGs from other edible plants, such as cassava, almond and sorghum by simultaneously expressing cyanide hydratase and β-glucosidase.

  6. Surface Analysis of Nerve Agent Degradation Products by ...

    EPA Pesticide Factsheets

    Report This sampling and analytical procedure was developed and applied by a single laboratory to investigate nerve agent degradation products, which may persist at a contaminated site, via surface wiping followed by analytical characterization. The performance data presented demonstrate the fitness-for-purpose regarding surface analysis in that single laboratory. Surfaces (laminate, glass, galvanized steel, vinyl tile, painted drywall and treated wood) were wiped with cotton gauze wipes, sonicated, extracted with distilled water, and filtered. Samples were analyzed with direct injection electrospray ionization liquid chromatography tandem mass spectrometry (ESI-LC/MS/MS) without derivatization. Detection limit data were generated for all analytes of interest on a laminate surface. Accuracy and precision data were generated from each surface fortified with these analytes.

  7. An Automated, High-Throughput Method for Interpreting the Tandem Mass Spectra of Glycosaminoglycans

    NASA Astrophysics Data System (ADS)

    Duan, Jiana; Jonathan Amster, I.

    2018-05-01

    The biological interactions between glycosaminoglycans (GAGs) and other biomolecules are heavily influenced by structural features of the glycan. The structure of GAGs can be assigned using tandem mass spectrometry (MS2), but analysis of these data, to date, requires manually interpretation, a slow process that presents a bottleneck to the broader deployment of this approach to solving biologically relevant problems. Automated interpretation remains a challenge, as GAG biosynthesis is not template-driven, and therefore, one cannot predict structures from genomic data, as is done with proteins. The lack of a structure database, a consequence of the non-template biosynthesis, requires a de novo approach to interpretation of the mass spectral data. We propose a model for rapid, high-throughput GAG analysis by using an approach in which candidate structures are scored for the likelihood that they would produce the features observed in the mass spectrum. To make this approach tractable, a genetic algorithm is used to greatly reduce the search-space of isomeric structures that are considered. The time required for analysis is significantly reduced compared to an approach in which every possible isomer is considered and scored. The model is coded in a software package using the MATLAB environment. This approach was tested on tandem mass spectrometry data for long-chain, moderately sulfated chondroitin sulfate oligomers that were derived from the proteoglycan bikunin. The bikunin data was previously interpreted manually. Our approach examines glycosidic fragments to localize SO3 modifications to specific residues and yields the same structures reported in literature, only much more quickly.

  8. A high-performance liquid chromatography-tandem mass spectrometry method coupled with protein precipitation for determination of granisetron in human plasma and its application to a comparative pharmacokinetic study.

    PubMed

    Zhou, Ying; Jiang, Ji; Hu, Pei; Wang, Hongyun

    2014-12-01

    A rapid, simple and validated method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) has been developed for the determination of granisetron in human plasma. Plasma samples were pre-purified by protein precipitation procedure. The chromatographic separation was achieved with Synergi Polar-RP (75 × 2 mm, 4 µm) column using a mixture of 5 mm pH4.0 ammonium formate and methanol (300:316, v/v) under isocratic conditions at a flow rate of 0.3 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The analysis time was about 2.5 min. The method was fully validated over the concentration range 0.1-10 ng/mL. The lower limit of quantification was 0.1 ng/mL. Inter- and intra-batch precision was <6.1% and the accuracy was within 95.6-100.0%. The mean extraction recovery was 96.3%. Selectivity, matrix effect and stability were also validated. The method was applied to the comparative pharmacokinetic study of granisetron in Chinese healthy subjects. Copyright © 2014 John Wiley & Sons, Ltd.

  9. Quantitative Caffeine Analysis Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, Michael J; Deibel, Michael A.; Tomkins, Bruce A

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methodsmore » determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.« less

  10. Alpha particle confinement in tandem mirrors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devoto, R.S.; Ohnishi, M.; Kerns, J.

    1980-10-10

    Mechanisms leading to loss of alpha particles from non-axisymmetric tandem mirrors are considered. Stochastic diffusion due to bounce-drift resonances, which can cause rapid radial losses of high-energy alpha particles, can be suppressed by imposing a 20% rise in axisymmetric fields before the quadrupole transition sections. Alpha particles should then be well-confined until thermal energies when they enter the resonant plateau require. A fast code for computation of drift behavior in reactors is described. Sample calculations are presented for resonant particles in a proposed coil set for the Tandem Mirror Next Step.

  11. Tandem mobile robot system

    DOEpatents

    Buttz, James H.; Shirey, David L.; Hayward, David R.

    2003-01-01

    A robotic vehicle system for terrain navigation mobility provides a way to climb stairs, cross crevices, and navigate across difficult terrain by coupling two or more mobile robots with a coupling device and controlling the robots cooperatively in tandem.

  12. Application of a validated stability-indicating densitometric thin-layer chromatographic method to stress degradation studies on moxifloxacin.

    PubMed

    Motwani, Sanjay K; Khar, Roop K; Ahmad, Farhan J; Chopra, Shruti; Kohli, K; Talegaonkar, S

    2007-01-16

    A simple, sensitive, selective, precise and stability-indicating high-performance thin-layer chromatographic (HPTLC) method for densitometric determination of moxifloxacin both as a bulk drug and from pharmaceutical formulation was developed and validated as per the International Conference on Harmonization (ICH) guidelines. The method employed TLC aluminium plates pre-coated with silica gel 60F-254 as the stationary phase and the mobile phase consisted of n-propanol-ethanol-6M ammonia solution (4:1:2, v/v/v). Densitometric analysis of moxifloxacin was carried out in the absorbance mode at 298 nm. Compact spots for moxifloxacin were found at R(f) value of 0.58+/-0.02. The linear regression analysis data for the calibration plots showed good linear relationship with r=0.9925 in the working concentration range of 100-800 ng spot(-1). The method was validated for precision, accuracy, ruggedness, robustness, specificity, recovery, limit of detection (LOD) and limit of quantitation (LOQ). The LOD and LOQ were 3.90 and 11.83 ng spot(-1), respectively. Drug was subjected to acid and alkali hydrolysis, oxidation, dry heat, wet heat treatment and photodegradation. All the peaks of degradation products were well resolved from the standard drug with significantly different R(f) values. Statistical analysis proves that the developed HPTLC method is reproducible and selective. As the method could effectively separate the drug from its degradation products, it can be employed as stability-indicating one. Moreover, the proposed HPTLC method was utilized to investigate the kinetics of the acidic and alkaline degradation processes at different temperatures. Arrhenius plot was constructed and apparent pseudo-first-order rate constant, half-life and activation energy were calculated. In addition the pH-rate profile for degradation of moxifloxacin in constant ionic strength buffer solutions within the pH range 1.2-10.8 was studied.

  13. The development of miniplex primer sets for the analysis of degraded DNA

    NASA Astrophysics Data System (ADS)

    McCord, Bruce; Opel, Kerry; Chung, Denise; Drabek, Jiri; Tatarek, Nancy; Meadows Jantz, Lee; Butler, John

    2005-05-01

    In this project, a new set of multiplexed PCR reactions has been developed for the analysis of degraded DNA. These DNA markers, known as Miniplexes, utilize primers that have shorter amplicons for use in short tandem repeat (STR) analysis of degraded DNA. In our work we have defined six of these new STR multiplexes, each of which consists of 3 to 4 reduced size STR loci, and each labeled with a different fluorescent dye. When compared to commercially available STR systems, reductions in size of up to 300 basepairs are possible. In addition, these newly designed amplicons consist of loci that are fully compatible with the the national computer DNA database known as CODIS. To demonstrate compatibility with commercial STR kits, a concordance study of 532 DNA samples of Caucasian, African American, and Hispanic origin was undertaken There was 99.77% concordance between allele calls with the two methods. Of these 532 samples, only 15 samples showed discrepancies at one of 12 loci. These occurred predominantly at 2 loci, vWA and D13S317. DNA sequencing revealed that these locations had deletions between the two primer binding sites. Uncommon deletions like these can be expected in certain samples and will not affect the utility of the Miniplexes as tools for degraded DNA analysis. The Miniplexes were also applied to enzymatically digested DNA to assess their potential in degraded DNA analysis. The results demonstrated a greatly improved efficiency in the analysis of degraded DNA when compared to commercial STR genotyping kits. A series of human skeletal remains that had been exposed to a variety of environmental conditions were also examined. Sixty-four percent of the samples generated full profiles when amplified with the Miniplexes, while only sixteen percent of the samples tested generated full profiles with a commercial kit. In addition, complete profiles were obtained for eleven of the twelve Miniplex loci which had amplicon size ranges less than 200 base pairs

  14. Direct and sensitive determination of glyphosate and aminomethylphosphonic acid in environmental water samples by high performance liquid chromatography coupled to electrospray tandem mass spectrometry.

    PubMed

    Guo, Hongyue; Riter, Leah S; Wujcik, Chad E; Armstrong, Daniel W

    2016-04-22

    A novel method based on high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) was developed for the sensitive determination of glyphosate and its major degradation product, AMPA in environmental water samples. The method involves the use of MS compatible mobile phases (0.1% formic acid in water and acetonitrile) for HPLC and direct analysis of water samples without sample derivatization. The method has been validated in different types of water matrices (drinking, surface and groundwater) by accuracy and precision studies with samples spiked at 0.1, 7.5 and 90 ppb. All mean accuracy values ranged from 85% to 112% for glyphosate and AMPA using both primary and secondary quantitative ion transitions (RSD ≤ 10%). Moreover, both primary and secondary ion transitions for glyphosate and AMPA can achieve the quantitation limits at 0.1 ppb. The linear dynamic range of the calibration curves were from 0.1 to 100 ppb for each analyte at each ion transitions with correlation coefficient higher than 0.997. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. A novel method for the rapid determination of polyethoxylated tallow amine surfactants in water and sediment using large volume injection with high performance liquid chromatography and tandem mass spectrometry.

    PubMed

    Ross, Andrew R S; Liao, Xiangjun

    2015-08-19

    Polyethoxylated tallow amine (POEA) surfactants have been used in many glyphosate-based herbicide formulations for agricultural, industrial and residential weed control. The potential for release of these compounds into the environment is of increasing concern due to their toxicity towards aquatic organisms. Current methods for analysis of POEA surfactants require significant time and effort to achieve limits of quantification that are often higher than the concentrations at which biological effects have been observed (as low as 2 ng mL(-1)). We have developed a rapid and robust method for quantifying the POEA surfactant mixture MON 0818 at biologically relevant concentrations in fresh water, sea water and lake sediment using reversed phase high-performance liquid chromatography and electrospray ionization-tandem mass spectrometry. Water samples preserved by 1:1 v/v dilution with methanol are analyzed directly following centrifugation. Sediment samples undergo accelerated solvent extraction in aqueous methanol prior to analysis. Large volume (100 μL) sample injection and multiple reaction monitoring of a subset of the most abundant POEA homologs provide limits of quantification of 0.5 and 2.9 ng mL(-1) for MON 0818 in fresh water and sea water, respectively, and 2.5 ng g(-1) for total MON 0818 in lake sediment. Average recoveries of 93 and 75% were achieved for samples of water and sediment, respectively spiked with known amounts of MON 0818. Precision and accuracy for the analysis of water and sediment samples were within 10 and 16%, respectively based upon replicate analyses of calibration standards and representative samples. Results demonstrate the utility of the method for quantifying undegraded MON 0818 in water and sediment, although a more comprehensive method may be needed to identify and determine other POEA mixtures and degradation profiles that might occur in the environment. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  16. Tandem internal models execute motor learning in the cerebellum.

    PubMed

    Honda, Takeru; Nagao, Soichi; Hashimoto, Yuji; Ishikawa, Kinya; Yokota, Takanori; Mizusawa, Hidehiro; Ito, Masao

    2018-06-25

    In performing skillful movement, humans use predictions from internal models formed by repetition learning. However, the computational organization of internal models in the brain remains unknown. Here, we demonstrate that a computational architecture employing a tandem configuration of forward and inverse internal models enables efficient motor learning in the cerebellum. The model predicted learning adaptations observed in hand-reaching experiments in humans wearing a prism lens and explained the kinetic components of these behavioral adaptations. The tandem system also predicted a form of subliminal motor learning that was experimentally validated after training intentional misses of hand targets. Patients with cerebellar degeneration disease showed behavioral impairments consistent with tandemly arranged internal models. These findings validate computational tandemization of internal models in motor control and its potential uses in more complex forms of learning and cognition. Copyright © 2018 the Author(s). Published by PNAS.

  17. Quality evaluation of tandem mass spectral libraries.

    PubMed

    Oberacher, Herbert; Weinmann, Wolfgang; Dresen, Sebastian

    2011-06-01

    Tandem mass spectral libraries are gaining more and more importance for the identification of unknowns in different fields of research, including metabolomics, forensics, toxicology, and environmental analysis. Particularly, the recent invention of reliable, robust, and transferable libraries has increased the general acceptance of these tools. Herein, we report on results obtained from thorough evaluation of the match reliabilities of two tandem mass spectral libraries: the MSforID library established by the Oberacher group in Innsbruck and the Weinmann library established by the Weinmann group in Freiburg. Three different experiments were performed: (1) Spectra of the libraries were searched against their corresponding library after excluding either this single compound-specific spectrum or all compound-specific spectra prior to searching; (2) the libraries were searched against each other using either library as reference set or sample set; (3) spectra acquired on different mass spectrometric instruments were matched to both libraries. Almost 13,000 tandem mass spectra were included in this study. The MSforID search algorithm was used for spectral matching. Statistical evaluation of the library search results revealed that principally both libraries enable the sensitive and specific identification of compounds. Due to higher mass accuracy of the QqTOF compared with the QTrap instrument, matches to the MSforID library were more reliable when comparing spectra with both libraries. Furthermore, only the MSforID library was shown to be efficiently transferable to different kinds of tandem mass spectrometers, including "tandem-in-time" instruments; this is due to the coverage of a large range of different collision energy settings-including the very low range-which is an outstanding characteristics of the MSforID library.

  18. Nanocrystal assembly for tandem catalysis

    DOEpatents

    Yang, Peidong; Somorjai, Gabor; Yamada, Yusuke; Tsung, Chia-Kuang; Huang, Wenyu

    2014-10-14

    The present invention provides a nanocrystal tandem catalyst comprising at least two metal-metal oxide interfaces for the catalysis of sequential reactions. One embodiment utilizes a nanocrystal bilayer structure formed by assembling sub-10 nm platinum and cerium oxide nanocube monolayers on a silica substrate. The two distinct metal-metal oxide interfaces, CeO.sub.2--Pt and Pt--SiO.sub.2, can be used to catalyze two distinct sequential reactions. The CeO.sub.2--Pt interface catalyzed methanol decomposition to produce CO and H.sub.2, which were then subsequently used for ethylene hydroformylation catalyzed by the nearby Pt--SiO.sub.2 interface. Consequently, propanal was selectively produced on this nanocrystal bilayer tandem catalyst.

  19. Single-task and dual-task tandem gait test performance after concussion.

    PubMed

    Howell, David R; Osternig, Louis R; Chou, Li-Shan

    2017-07-01

    To compare single-task and dual-task tandem gait test performance between athletes after concussion with controls on observer-timed, spatio-temporal, and center-of-mass (COM) balance control measurements. Ten participants (19.0±5.5years) were prospectively identified and completed a tandem gait test protocol within 72h of concussion and again 1 week, 2 weeks, 1 month, and 2 months post-injury. Seven uninjured controls (20.0±4.5years) completed the same protocol in similar time increments. Tandem gait test trials were performed with (dual-task) and without (single-task) concurrently performing a cognitive test as whole-body motion analysis was performed. Outcome variables included test completion time, average tandem gait velocity, cadence, and whole-body COM frontal plane displacement. Concussion participants took significantly longer to complete the dual-task tandem gait test than controls throughout the first 2 weeks post-injury (mean time=16.4 [95% CI: 13.4-19.4] vs. 10.1 [95% CI: 6.4-13.7] seconds; p=0.03). Single-task tandem gait times were significantly lower 72h post-injury (p=0.04). Dual-task cadence was significantly lower for concussion participants than controls (89.5 [95% CI: 68.6-110.4] vs. 127.0 [95% CI: 97.4-156.6] steps/minute; p=0.04). Moderately-high to high correlations between tandem gait test time and whole-body COM medial-lateral displacement were detected at each time point during dual-task gait (r s =0.70-0.93; p=0.03-0.001). Adding a cognitive task during the tandem gait test resulted in longer detectable deficits post-concussion compared to the traditional single-task tandem gait test. As a clinical tool to assess dynamic motor function, tandem gait may assist with return to sport decisions after concussion. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  20. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; a method supplement for the determination of Fipronil and degradates in water by gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Madsen, James F.; Sandstrom, Mark W.; Zaugg, Steven D.

    2002-01-01

    A method for the isolation and detemrination of fipronil and four of its degradates has been developed. This method adapts an analytical method created by the U.S. Geological Survey National Water Quality Laboratory in 1995 for the determination of a broad range of high-use pesticides typically found in filtered natural-water samples. In 2000, fipronil and four of its degradates were extracted, analyzed, and validated using this method. The recoveries for these five compounds in reagent-water samples fortified at 1 microgram per liter (ug/L) avereraged 98 percent. Initial method detection limits averaged 0.0029 ug/L. The performance of these five new compounds is consistent with the performance of the compounds in the initial method, making it possible to include them in addition to the other 41 pesticides and pesticide degradates in the original method.

  1. Fast identification of microplastics in complex environmental samples by a thermal degradation method.

    PubMed

    Dümichen, Erik; Eisentraut, Paul; Bannick, Claus Gerhard; Barthel, Anne-Kathrin; Senz, Rainer; Braun, Ulrike

    2017-05-01

    In order to determine the relevance of microplastic particles in various environmental media, comprehensive investigations are needed. However, no analytical method exists for fast identification and quantification. At present, optical spectroscopy methods like IR and RAMAN imaging are used. Due to their time consuming procedures and uncertain extrapolation, reliable monitoring is difficult. For analyzing polymers Py-GC-MS is a standard method. However, due to a limited sample amount of about 0.5 mg it is not suited for analysis of complex sample mixtures like environmental samples. Therefore, we developed a new thermoanalytical method as a first step for identifying microplastics in environmental samples. A sample amount of about 20 mg, which assures the homogeneity of the sample, is subjected to complete thermal decomposition. The specific degradation products of the respective polymer are adsorbed on a solid-phase adsorber and subsequently analyzed by thermal desorption gas chromatography mass spectrometry. For certain identification, the specific degradation products for the respective polymer were selected first. Afterwards real environmental samples from the aquatic (three different rivers) and the terrestrial (bio gas plant) systems were screened for microplastics. Mainly polypropylene (PP), polyethylene (PE) and polystyrene (PS) were identified for the samples from the bio gas plant and PE and PS from the rivers. However, this was only the first step and quantification measurements will follow. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Negotiating Multiple Identities through eTandem Learning Experiences

    ERIC Educational Resources Information Center

    Yang, Se Jeong; Yi, Youngjoo

    2017-01-01

    Much of eTandem research has investigated either linguistic or cross-cultural aspects of second language (L2) learning, but relatively little is known about issues of identity construction in an eTandem context. Situating the study within theories and research of language learner identity, we examined ways in which two adult L2 learners (a Korean…

  3. Optimizing Algorithm Choice for Metaproteomics: Comparing X!Tandem and Proteome Discoverer for Soil Proteomes

    NASA Astrophysics Data System (ADS)

    Diaz, K. S.; Kim, E. H.; Jones, R. M.; de Leon, K. C.; Woodcroft, B. J.; Tyson, G. W.; Rich, V. I.

    2014-12-01

    The growing field of metaproteomics links microbial communities to their expressed functions by using mass spectrometry methods to characterize community proteins. Comparison of mass spectrometry protein search algorithms and their biases is crucial for maximizing the quality and amount of protein identifications in mass spectral data. Available algorithms employ different approaches when mapping mass spectra to peptides against a database. We compared mass spectra from four microbial proteomes derived from high-organic content soils searched with two search algorithms: 1) Sequest HT as packaged within Proteome Discoverer (v.1.4) and 2) X!Tandem as packaged in TransProteomicPipeline (v.4.7.1). Searches used matched metagenomes, and results were filtered to allow identification of high probability proteins. There was little overlap in proteins identified by both algorithms, on average just ~24% of the total. However, when adjusted for spectral abundance, the overlap improved to ~70%. Proteome Discoverer generally outperformed X!Tandem, identifying an average of 12.5% more proteins than X!Tandem, with X!Tandem identifying more proteins only in the first two proteomes. For spectrally-adjusted results, the algorithms were similar, with X!Tandem marginally outperforming Proteome Discoverer by an average of ~4%. We then assessed differences in heat shock proteins (HSP) identification by the two algorithms by BLASTing identified proteins against the Heat Shock Protein Information Resource, because HSP hits typically account for the majority signal in proteomes, due to extraction protocols. Total HSP identifications for each of the 4 proteomes were approximately ~15%, ~11%, ~17%, and ~19%, with ~14% for total HSPs with redundancies removed. Of the ~15% average of proteins from the 4 proteomes identified as HSPs, ~10% of proteins and spectra were identified by both algorithms. On average, Proteome Discoverer identified ~9% more HSPs than X!Tandem.

  4. Improve definition of titanium tandems in MR-guided high dose rate brachytherapy for cervical cancer using proton density weighted MRI

    PubMed Central

    2013-01-01

    Background For cervical cancer patients treated with MR-guided high dose rate brachytherapy, the accuracy of radiation delivery depends on accurate localization of both tumors and the applicator, e.g. tandem and ovoid. Standard T2-weighted (T2W) MRI has good tumor-tissue contrast. However, it suffers from poor uterus-tandem contrast, which makes the tandem delineation very challenging. In this study, we evaluated the possibility of using proton density weighted (PDW) MRI to improve the definition of titanium tandems. Methods Both T2W and PDW MRI images were obtained from each cervical cancer patient. Imaging parameters were kept the same between the T2W and PDW sequences for each patient except the echo time (90 ms for T2W and 5.5 ms for PDW) and the slice thickness (0.5 cm for T2W and 0.25 cm for PDW). Uterus-tandem contrast was calculated by the equation C = (Su-St)/Su, where Su and St represented the average signal in the uterus and the tandem, respectively. The diameter of the tandem was measured 1.5 cm away from the tip of the tandem. The tandem was segmented by the histogram thresholding technique. Results PDW MRI could significantly improve the uterus-tandem contrast compared to T2W MRI (0.42±0.24 for T2W MRI, 0.77±0.14 for PDW MRI, p=0.0002). The average difference between the measured and physical diameters of the tandem was reduced from 0.20±0.15 cm by using T2W MRI to 0.10±0.11 cm by using PDW MRI (p=0.0003). The tandem segmented from the PDW image looked more uniform and complete compared to that from the T2W image. Conclusions Compared to the standard T2W MRI, PDW MRI has better uterus-tandem contrast. The information provided by PDW MRI is complementary to those provided by T2W MRI. Therefore, we recommend adding PDW MRI to the simulation protocol to assist tandem delineation process for cervical cancer patients. PMID:23327682

  5. Multi-locus variable number tandem repeat analysis for Escherichia coli causing extraintestinal infections.

    PubMed

    Manges, Amee R; Tellis, Patricia A; Vincent, Caroline; Lifeso, Kimberley; Geneau, Geneviève; Reid-Smith, Richard J; Boerlin, Patrick

    2009-11-01

    Discriminatory genotyping methods for the analysis of Escherichia coli other than O157:H7 are necessary for public health-related activities. A new multi-locus variable number tandem repeat analysis protocol is presented; this method achieves an index of discrimination of 99.5% and is reproducible and valid when tested on a collection of 836 diverse E. coli.

  6. A liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric method for the determination of organosulfur compounds in petroleum asphalt cements.

    PubMed

    da Silveira, Géssica Domingos; Faccin, Henrique; Claussen, Luis; Goularte, Rayane Bueno; Do Nascimento, Paulo C; Bohrer, Denise; Cravo, Margareth; Leite, Leni F M; de Carvalho, Leandro Machado

    2016-07-29

    We present a sensitive liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric (UHPLC-APPI-MS/MS) method for the determination of selected organosulfur compounds in Brazilian asphalt cements. It was possible to detect 14 organosulfur compounds of different classes where sulfoxides and sulfones presented higher sensibility in ionization than thiophenes and aromatic sulfides. A dopant-assisted APPI method was also tested, however, when chromatographic flow rate was optimized a decrease in signal was observed for all compounds. PAHs were tested and ruled out as possible interfering compounds and the matrix effect of asphalt cements was within an acceptable range for the quantification of organosulfur compounds. The proposed method was found to have satisfactory linearity and accuracy with recoveries between 83.85 and 110.28% for thianaphthene and 3-methylbenzothiophene, respectively. Therefore, the method allowed the characterization of organosulfur compounds in Brazilian asphalt cements and demonstrated changes in the amount quantified in asphaltenic and maltenic fractions after the RTFOT+SUNTEST aging process. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. SYMTRAN - A Time-dependent Symmetric Tandem Mirror Transport Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hua, D; Fowler, T

    2004-06-15

    A time-dependent version of the steady-state radial transport model in symmetric tandem mirrors in Ref. [1] has been coded up and first tests performed. Our code, named SYMTRAN, is an adaptation of the earlier SPHERE code for spheromaks, now modified for tandem mirror physics. Motivated by Post's new concept of kinetic stabilization of symmetric mirrors, it is an extension of the earlier TAMRAC rate-equation code omitting radial transport [2], which successfully accounted for experimental results in TMX. The SYMTRAN code differs from the earlier tandem mirror radial transport code TMT in that our code is focused on axisymmetric tandem mirrorsmore » and classical diffusion, whereas TMT emphasized non-ambipolar transport in TMX and MFTF-B due to yin-yang plugs and non-symmetric transitions between the plugs and axisymmetric center cell. Both codes exhibit interesting but different non-linear behavior.« less

  8. Quantification of rifampicin in human plasma and cerebrospinal fluid by a highly sensitive and rapid liquid chromatographic-tandem mass spectrometric method.

    PubMed

    Srivastava, Abhishek; Waterhouse, David; Ardrey, Alison; Ward, Stephen A

    2012-11-01

    A highly sensitive and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed to measure the levels of the antitubercular drug rifampicin (RIF) in human plasma and cerebrospinal fluid (CSF). The analyte and internal standard (IS) were isolated from plasma and CSF by a simple organic solvent based precipitation of proteins followed by centrifugation. Detection was carried out by electrospray positive ionization mass spectrometry in the multiple-reaction monitoring (MRM) mode. The assay was linear in the concentration range 25-6400 ng/mL with intra- and inter-day precision of <7% and <8%, respectively. The validated method was applied to the study of RIF pharmacokinetics in human CSF and plasma over 25 h period after a 10 mg/kg oral dose. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. A novel typing method for Listeria monocytogenes using high-resolution melting analysis (HRMA) of tandem repeat regions.

    PubMed

    Ohshima, Chihiro; Takahashi, Hajime; Iwakawa, Ai; Kuda, Takashi; Kimura, Bon

    2017-07-17

    Listeria monocytogenes, which is responsible for causing food poisoning known as listeriosis, infects humans and animals. Widely distributed in the environment, this bacterium is known to contaminate food products after being transmitted to factories via raw materials. To minimize the contamination of products by food pathogens, it is critical to identify and eliminate factory entry routes and pathways for the causative bacteria. High resolution melting analysis (HRMA) is a method that takes advantage of differences in DNA sequences and PCR product lengths that are reflected by the disassociation temperature. Through our research, we have developed a multiple locus variable-number tandem repeat analysis (MLVA) using HRMA as a simple and rapid method to differentiate L. monocytogenes isolates. While evaluating our developed method, the ability of MLVA-HRMA, MLVA using capillary electrophoresis, and multilocus sequence typing (MLST) was compared for their ability to discriminate between strains. The MLVA-HRMA method displayed greater discriminatory ability than MLST and MLVA using capillary electrophoresis, suggesting that the variation in the number of repeat units, along with mutations within the DNA sequence, was accurately reflected by the melting curve of HRMA. Rather than relying on DNA sequence analysis or high-resolution electrophoresis, the MLVA-HRMA method employs the same process as PCR until the analysis step, suggesting a combination of speed and simplicity. The result of MLVA-HRMA method is able to be shared between different laboratories. There are high expectations that this method will be adopted for regular inspections at food processing facilities in the near future. Copyright © 2017. Published by Elsevier B.V.

  10. Methods to identify enzymes that degrade the main extracellular polysaccharide component of Staphylococcus epidermidis biofilms

    PubMed Central

    Gökçen, Anke; Vilcinskas, Andreas; Wiesner, Jochen

    2013-01-01

    The production of extracellular poly-β-1,6-N-acetyl-d-glucosamine (PNAG) by Staphylococcus epidermidis is the principal determinant of biofilm formation on indwelling medical devices. Enzymes that degrade PNAG therefore provide an attractive strategy for biofilm removal and for the manufacture of biofilm-resistant coatings. Here we present methods that allow the identification of PNAG-degrading enzymes with the ability to detach biofilms. Our protocol includes the preparation of soluble PNAG from S. epidermidis cultures, the incubation of soluble PNAG with candidate enzymes and assays that detect the release of N-acetyl-d-glucosamine using high-pH anion-exchange chromatography (HPAEC) followed in parallel by pulsed amperometric detection (PAD) and online electrospray ionization mass spectrometry (ESI-MS). We validated our procedures using dispersin B, which is currently the only known PNAG-degrading enzyme. PMID:23357872

  11. Liquid chromatography/tandem mass spectrometry with fluorous derivatization method for selective analysis of sialyl oligosaccharides.

    PubMed

    Sakaguchi, Yohei; Hayama, Tadashi; Yoshida, Hideyuki; Itoyama, Miki; Todoroki, Kenichiro; Yamaguchi, Masatoshi; Nohta, Hitoshi

    2014-12-15

    A separation-oriented derivatization method using a specific fluorous affinity between perfluoroalkyl-containing compounds was applied to selective liquid chromatography/tandem mass spectrometric (LC/MS/MS) analysis of sialyl oligosaccharides. The perfluoroalkyl-labeled sialyl oligosaccharides could be selectively retained on an LC column with the perfluoroalkyl-modified stationary phase and effectively distinguished from non-derivatized species. Sialyl oligosaccharides (3'-sialyllactose, 6'-sialyllactose, sialyllacto-N-tetraose a, sialyllacto-N-tetraose b, sialyllacto-N-tetraose c, and disialyllacto-N-tetraose) were derivatized with 4,4,5,5,6,6,7,7,8,8,9,9,10,10,11,11,11-heptadecafluoroundecylamine via amidation in the presence of 4-(4,6-dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride (condensation reagent). The obtained derivatives were directly injected onto the fluorous LC column without any pretreatments and then detected by positive electrospray ionization MS/MS. The method enabled accurate determination of the sialyl oligosaccharides in biological samples such as human urine and human milk, because there was no interference with matrix-induced effects during LC/MS/MS analysis. The limits of detection of the examined sialyl oligosaccharides, defined as signal-to-noise (S/N) = 3, were in the range 0.033-0.13 nM. Accuracy in the range 95.6-108% was achieved, and the precision (relative standard deviation) was within 9.4%. This method enabled highly selective and sensitive analysis of sialyl oligosaccharides, enabling accurate measurement of even their trace amounts in biological matrices. The proposed method may prove to be a powerful tool for the analysis of various sialyl oligosaccharides. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Application of plasma electrolysis method for simultaneous phenol and Cr(VI) wastewater degradation using Na2SO4 electrolyte

    NASA Astrophysics Data System (ADS)

    Harianti, Aulia Rahmi; Saksono, Nelson

    2017-11-01

    Phenol and Cr (VI) are two types of wastewater known as dangerous and difficult to degrade. Through this study, phenol and Cr (VI) metal wastewater were degraded simultaneously using plasma electrolysis method by reactive species, •OH and H•. The variation of anode depth and position of plasma formation as independent variables correlated with yield of hydroxyl radical, percentage of phenol and Cr (VI) degradation, and specific energy. Within 30 minutes, phenol was degraded to 98.4% and Cr (VI) was degraded to 93.35% with 171.05 kJ/mmol in specific energy, and 174.53 ppm in COD. The optimum condition was obtained in anodic plasma and 1.5 cm in anode depth. The highest degradation percentage of phenol and Cr (VI) were 99.79% and 97.33% achieved during 180 minutes of plasma electrolysis process.

  13. AlGaInP/GaAs tandem solar cells for power conversion at 400°C and high concentration

    NASA Astrophysics Data System (ADS)

    Steiner, Myles A.; Perl, Emmett E.; Simon, John; Friedman, Daniel J.; Jain, Nikhil; Sharps, Paul; McPheeters, Claiborne; Lee, Minjoo Larry

    2017-09-01

    We demonstrate dual junction (Al)GaInP/GaAs solar cells that are designed to operate at 400°C and 1000X concentration in a hybrid photovoltaic-solar thermal concentrator system. The cells have a front metallization and anti-reflection coating that are stable under 400°C operation. We show how the cell performance degrades with increasing aluminum compositions in the top cell. Our best cell is a GaInP/GaAs tandem that demonstrated 15±1% efficiency at 400°C over a concentration range of 300-1000 suns, with several pathways to improved performance.

  14. Multiclass method for the quantification of 92 veterinary antimicrobial drugs in livestock excreta, wastewater, and surface water by liquid chromatography with tandem mass spectrometry.

    PubMed

    Gao, Jinfang; Cui, Yonghui; Tao, Yanfei; Huang, Lingli; Peng, Dapeng; Xie, Shuyu; Wang, Xu; Liu, Zhenli; Chen, Dongmei; Yuan, Zonghui

    2016-11-01

    A simple multiresidue method was developed for detecting and quantifying 92 veterinary antimicrobial drugs from eight classes (β-lactams, quinolones, sulfonamides, tetracyclines, lincomycins, macrolides, chloramphenicols, and pleuromutilin) in livestock excreta and water by liquid chromatography with tandem mass spectrometry. The feces samples were extracted by ultrasound-assisted extraction with a mixture of acetonitrile/water (80:20, v/v) and edetate disodium, followed by a cleanup using solid-phase extraction with an amino cartridge. Water samples were purified with hydrophilic-lipophilic balance solid-phase extraction column. Urine samples were extracted with acetonitrile and edetate disodium. Detection of veterinary antimicrobial drugs was achieved by liquid chromatography with tandem mass spectrometry using both positive and negative electrospray ionization mode. The recovery values of veterinary antimicrobial drugs in feces, urine, and water samples were 75-99, 85-110, and 85-101% and associated relative standard deviations were less than 15, 10, and 8%, respectively. The limits of quantification in feces, urine, and water samples were 0.5-1, 0.5-1, and 0.01-0.05 μg/L, respectively. This method was applied to determine real samples obtained from local farms and provides reliable quantification and identification results of 92 veterinary antimicrobial drugs in livestock excreta and water. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Development of a multiresidue method for the determination of endocrine disrupters in fish fillet using gas chromatography-triple quadrupole tandem mass spectrometry.

    PubMed

    Munaretto, Juliana S; Ferronato, Giovana; Ribeiro, Lucila C; Martins, Manoel L; Adaime, Martha B; Zanella, Renato

    2013-11-15

    Endocrine Disrupter Compounds (EDCs) are responsible for alterations in the endocrine system functions. Aquatic organisms are able to accumulate EDCs residues, being the major source of contamination for top predators and human consumers. This study aimed to develop and validate a method for the determination of 40 EDCs in fish fillet using modified QuEChERS and Gas Chromatography coupled with Mass Spectrometry in tandem (GC-MS/MS). A factorial design was used to optimize the extraction procedure. Method validation presented recoveries from 70.1% to 120.0% with RSD<20% and method limit of detection ranged from 0.3 to 7.5 µg kg(-1), showing good accuracy and precision. This method was successfully applied to the analysis of fish fillet from different species and residues of bisphenol A, chlorpyrifos and bifenthrin were detected. The proposed method proved to be effective for the determination of EDCs in fish fillet at very low concentration levels. © 2013 Elsevier B.V. All rights reserved.

  16. Control of surface thermal scratch of strip in tandem cold rolling

    NASA Astrophysics Data System (ADS)

    Chen, Jinshan; Li, Changsheng

    2014-07-01

    The thermal scratch seriously affects the surface quality of the cold rolled stainless steel strip. Some researchers have carried out qualitative and theoretical studies in this field. However, there is currently a lack of research on effective forecast and control of thermal scratch defects in practical production, especially in tandem cold rolling. In order to establish precise mathematical model of oil film thickness in deformation zone, the lubrication in cold rolling process of SUS410L stainless steel strip is studied, and major factors affecting oil film thickness are also analyzed. According to the principle of statistics, mathematical model of critical oil film thickness in deformation zone for thermal scratch is built, with fitting and regression analytical method, and then based on temperature comparison method, the criterion for deciding thermal scratch defects is put forward. Storing and calling data through SQL Server 2010, a software on thermal scratch defects control is developed through Microsoft Visual Studio 2008 by MFC technique for stainless steel in tandem cold rolling, and then it is put into practical production. Statistics indicate that the hit rate of thermal scratch is as high as 92.38%, and the occurrence rate of thermal scratch is decreased by 89.13%. Owing to the application of the software, the rolling speed is increased by approximately 9.3%. The software developed provides an effective solution to the problem of thermal scratch defects in tandem cold rolling, and helps to promote products surface quality of stainless steel strips in practical production.

  17. Developing Effective Continuous On-Line Monitoring Technologies to Manage Service Degradation of Nuclear Power Plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, Ryan M.; Ramuhalli, Pradeep; Bond, Leonard J.

    2011-09-30

    Recently, there has been increased interest in using prognostics (i.e, remaining useful life (RUL) prediction) for managing and mitigating aging effects in service-degraded passive nuclear power reactor components. A vital part of this philosophy is the development of tools for detecting and monitoring service-induced degradation. Experience with in-service degradation has shown that rapidly-growing cracks, including several varieties of stress corrosion cracks (SCCs), can grow through a pipe in less than one fuel outage cycle after they initiate. Periodic inspection has limited effectiveness at detecting and managing such degradation requiring a more versatile monitoring philosophy. Acoustic emission testing (AET) and guidedmore » wave ultrasonic testing (GUT) are related technologies with potential for on-line monitoring applications. However, harsh operating conditions within NPPs inhibit the widespread implementation of both technologies. For AET, another hurdle is the attenuation of passive degradation signals as they travel though large components, relegating AET to targeted applications. GUT is further hindered by the complexity of GUT signatures limiting its application to the inspection of simple components. The development of sensors that are robust and inexpensive is key to expanding the use of AET and GUT for degradation monitoring in NPPs and improving overall effectiveness. Meanwhile, the effectiveness of AET and GUT in NPPs can be enhanced through thoughtful application of tandem AET-GUT techniques.« less

  18. Treating Refractory Cardiogenic Shock With the TandemHeart and Impella Devices: A Single Center Experience

    PubMed Central

    Schwartz, Bryan G.; Ludeman, Daniel J.; Mayeda, Guy S.; Kloner, Robert A.; Economides, Christina; Burstein, Steven

    2012-01-01

    Background Patients with cardiogenic shock (CS) are routinely treated with intra-aortic balloon pumps (IABPs). The utility of 2 new percutaneous left ventricular assist devices (PLVADs), the Impella and TandemHeart, is unknown. The objective of this study was to describe the use of PLVADs for patients with CS at our institution. Methods All cases involving PLVADs in patients with CS between between January 1, 2008 and June 30, 2010 at a private, tertiary referral hospital were reviewed retrospectively. Results All 76 cases were identified (50 IABP only, 7 Impella, 19 TandemHeart). Most Impella (5/7) and TandemHeart (10/19) patients were initially treated with an IABP before "upgrading" for increased hemodynamic support. All 76 devices (100%) were initiated successfully. Percutaneous revascularization was attempted in 63 patients with angiographic success in 57 (90%). The incidences of major complications were similar between groups, except bleeding occurred less frequently with the IABP. Mean ejection fraction on presentation was 30.4±16.5% and increased by a mean of 6.6±11.4% (P < 0.001). With the institutional approach of treating patients with CS initially with vasopressors and IABPs, then upgrading to an Impella or TandemHeart device for patients refractory to IABP therapy, the overall mortality rate was 40%. Conclusion The Impella and TandemHeart devices can be initiated successfully in patients with CS, are associated with high rates of angiographic success during high risk percutaneous interventions and may benefit the myocardium during myocardial infarction. Randomized trials are warranted investigating use of the Impella and TandemHeart devices in patients with CS and in patients refractory to conventional IABP therapy. PMID:28348673

  19. Bait type influences on catch and bycatch in tandem hoop nets set in reservoirs

    USGS Publications Warehouse

    Long, James M.; Stewart, David R.; Shiflet, Jeremy; Balsman, Dane; Shoup, Daniel E.

    2017-01-01

    Tandem hoop nets have become the primary gear for sampling channel catfish Ictalurus punctatus, but suffer from high incidences of bycatch, particularly aquatic turtles that usually drown as a result. We sought to determine if bait type, ZOTE© soap and ground cheese logs, would influence catch of channel catfish (CPUE and mean TL) and bycatch of fishes and aquatic turtles. We sampled with tandem hoop nets in 13 Kentucky reservoirs (5–73 ha) using a crossover design and two sampling events. We found no difference in channel catfish catch rates between bait types, but mean sizes of fish caught using ZOTE© soap were approximately 24 mm longer compared to cheese. Fish bycatch was similar between bait types, but tandem hoop nets baited with ZOTE© soap caught up to 61% fewer turtles and mortality of turtles that were captured was up to 12% lower than those baited with cheese. Depth of net set, water temperature, and Secchi depth were environmental factors measured that affected catch and bycatch, but varied among species. Using ZOTE© soap as bait in tandem hoop nets appears to be a fairly simple and straightforward method for maintaining high catch rates of channel catfish while minimizing turtle mortality.

  20. Fast atom bombardment tandem mass spectrometry of carotenoids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    van Breeman, R.B.; Schmitz, H.H.; Schwartz, S.J.

    Positive ion fast atom bombardment (FAB) tandem mass spectrometry (MS-MS) using a double-focusing mass spectrometer with linked scanning at constant B/E and high-energy collisionally activated dissociation (CAD) was used to differentiate 17 different cartenoids, including {beta}-apo-8{prime}- carotenal, astaxanthin, {alpha}-carotene, {beta}-carotene, {gamma}-carotene, {zeta}-carotene, canthaxanthin, {beta}-cryptoxanthin, isozeaxanthin bis (pelargonate), neoxanthin, neurosporene, nonaprene, lutein, lycopene, phytoene, phytofluene, and zeaxanthin. The carotenoids were either synthetic or isolated from plant tissues. The use of FAB ionization minimized degradation or rearrangement of the carotenoid structures due to the inherent thermal instability generally ascribed to these compounds. Instead of protonated molecules, both polar xanthophylls and nonpolar carotenesmore » formed molecular ions, M{sup {center_dot}+}, during FAB ionization. Following collisionally activated dissociation, fragment ions of selected molecular ion precursors showed structural features indicative of the presence of hydroxyl groups, ring systems, ester groups, and aldehyde groups and the extent of aliphatic polyene conjugation. The fragmentation patterns observed in the mass spectra herein may be used as a reference for the structural determination of carotenoids isolated from plant and animal tissues. 18 refs., 4 figs.« less

  1. Liquid chromatography-tandem mass spectrometry method for the measurement of serum mevalonic acid: a novel marker of hydroxymethylglutaryl coenzyme A reductase inhibition by statins.

    PubMed

    Waldron, Jenna; Webster, Craig

    2011-05-01

    Mevalonic acid (MVA) is synthesized at an early and rate-limiting step in the biosynthesis of cholesterol by the enzyme hydroxymethylglutaryl coenzyme A (HMG-CoA) reductase, and is a useful measure of statin efficacy or treatment. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the measurement of serum MVA has been developed. Following the in vitro conversion of MVA to mevalonic acid lactone (MVAL) in the serum, MVAL and a deuterated internal standard were extracted using an online solid-phase extraction procedure. Chromatographic separation was achieved using a Luna PFP column (Phenomenex), with enhanced selectivity and improved resolution for polar compounds. A gradient system was used, with mobile phase comprising methanol and water (5 mmol/L ammonium formate buffer, pH 2.5). Analysis was performed using an API 5000 tandem mass spectrometer (Applied Biosystems) in positive electrospray ionization mode. The method showed excellent recoveries (98 ± 8%) and imprecision (intra-assay coefficient of variation of 2.2% [6.5 ng/mL] and 2.6% [10.5 ng/mL], and inter-assay coefficient of variation of 9% [10.5 ng/mL]). The assay provides a calibration range up to 50 ng/mL with a limit of detection at 0.1 ng/mL. A simple, rapid and analytically specific method has been developed for the measurement of serum MVA, in the form of MVAL. The high analytical sensitivity of the method allows for accurate quantitation of MVAL in serum samples, both at the endogenous levels found in healthy individuals and in statin-treated patients where normal levels are expected to be greatly reduced through the inhibition of HMG-CoA reductase.

  2. Cooperative cell motility during tandem locomotion of amoeboid cells

    PubMed Central

    Bastounis, Effie; Álvarez-González, Begoña; del Álamo, Juan C.; Lasheras, Juan C.; Firtel, Richard A.

    2016-01-01

    Streams of migratory cells are initiated by the formation of tandem pairs of cells connected head to tail to which other cells subsequently adhere. The mechanisms regulating the transition from single to streaming cell migration remain elusive, although several molecules have been suggested to be involved. In this work, we investigate the mechanics of the locomotion of Dictyostelium tandem pairs by analyzing the spatiotemporal evolution of their traction adhesions (TAs). We find that in migrating wild-type tandem pairs, each cell exerts traction forces on stationary sites (∼80% of the time), and the trailing cell reuses the location of the TAs of the leading cell. Both leading and trailing cells form contractile dipoles and synchronize the formation of new frontal TAs with ∼54-s time delay. Cells not expressing the lectin discoidin I or moving on discoidin I–coated substrata form fewer tandems, but the trailing cell still reuses the locations of the TAs of the leading cell, suggesting that discoidin I is not responsible for a possible chemically driven synchronization process. The migration dynamics of the tandems indicate that their TAs’ reuse results from the mechanical synchronization of the leading and trailing cells’ protrusions and retractions (motility cycles) aided by the cell–cell adhesions. PMID:26912787

  3. Degradation of Remazol Red in batik dye waste water by contact glow discharge electrolysis method using NaOH and NaCl electrolytes

    NASA Astrophysics Data System (ADS)

    Saksono, Nelson; Putri, Dita Amelia; Suminar, Dian Ratna

    2017-03-01

    Contact Glow Discharge Electrolysis (CGDE) method is one of Plasma Electrolysis technology which has been approved to degrade organic waste water because it is very productive in producing hydroxyl radical. This study aims to degrade Remazol Red by CGDE method and evaluate important parameters that have influent in degradation process of Remazol Red in Batik dye waste water in batch system. The kind of electrolyte (acid and base) and the addition of metal ion such as Fe2+ have affected Remazol Red degradation percentage. Ultraviolet-Visible (UV-Vis) absorption spectra were used to monitor the degradation process. The result of study showed that percentage degradation was 99.97% which obtained by using NaCl 0.02 M with addition Fe2+ 20 ppm, applied voltage 700 volt, anode depth 0.5 cm, initial concentration of Remazol Red 250 ppm and the temperature of solutions was maintained 50-60 ˚C.

  4. DNA Damage by Ionizing Radiation: Tandem Double Lesions by Charged Particles

    NASA Technical Reports Server (NTRS)

    Huo, Winifred M.; Chaban, Galina M.; Wang, Dunyou; Dateo, Christopher E.

    2005-01-01

    Oxidative damages by ionizing radiation are the source of radiation-induced carcinogenesis, damage to the central nervous system, lowering of the immune response, as well as other radiation-induced damages to human health. Monte Carlo track simulations and kinetic modeling of radiation damages to the DNA employ available molecular and cellular data to simulate the biological effect of high and low LET radiation io the DNA. While the simulations predict single and double strand breaks and base damages, so far all complex lesions are the result of stochastic coincidence from independent processes. Tandem double lesions have not yet been taken into account. Unlike the standard double lesions that are produced by two separate attacks by charged particles or radicals, tandem double lesions are produced by one single attack. The standard double lesions dominate at the high dosage regime. On the other hand, tandem double lesions do not depend on stochastic coincidences and become important at the low dosage regime of particular interest to NASA. Tandem double lesions by hydroxyl radical attack of guanine in isolated DNA have been reported at a dosage of radiation as low as 10 Gy. The formation of two tandem base lesions was found to be linear with the applied doses, a characteristic of tandem lesions. However, tandem double lesions from attack by a charged particle have not been reported.

  5. A tandem mirror hybrid plume plasma propulsion facility

    NASA Technical Reports Server (NTRS)

    Yang, T. F.; Krueger, W. A.; Peng, S.; Urbahn, J.; Chang-Diaz, F. R.

    1988-01-01

    This paper discusses a novel concept in electrodeless plasma propulsion, in which the materials problems are ameliorated by an electrodeless magnetic confinement scheme borrowed from the tandem mirror approach to controlled thermonuclear fusion. The concept also features a two-stage magnetic nozzle with an annular hypersonic coaxial gas injector near the throat. The nozzle produces hybrid plume by the coaxial injection of hypersonic neutral gas, and the gas layer thus formed protects the material walls from the hot plasma and, through increased collisions, helps detach it from the diverging magnetic field. The tandem mirror plasma propulsion facility is capable of delivering a variable I(sp). The results of numerical simulation of this concept are presented together with those from an experimental tandem-mirror plasma propulsion device.

  6. Preparation and characterization of two new forced degradation products of letrozole and development of a stability-indicating RP-LC method for its determination.

    PubMed

    Elkady, Ehab Farouk; Fouad, Marwa Ahmed

    2015-11-01

    Two new hydrolytic products of letrozole were identified and proved to be true degradation products obtained by alkaline and acidic degradation of the drug. The acid and amide forms of the nitrile groups of letrozole were prepared and identified by IR and mass spectroscopic techniques. Subsequently, a simple, precise and selective stability-indicating RPLC method was developed and validated for the determination of letrozole in the presence of its degradation products. Letrozole was subjected to alkali and acid hydrolysis, oxidation, thermal degradation and photo-degradation. The degradation products were well isolated from letrozole. The chromatographic method was achieved using gradient elution of the drug and its degradation products on a reversed phase Zorbax Eclipse C18 column (100mm x 4.6mm, 3.5 μm) using a mobile phase consisting of 0.01M KH₂PO₄and methanol at a flow rate of 1 mL min⁻¹. Quantitation was achieved with UV detection at 230 nm. Linearity, accuracy and precision were found to be acceptable over the concentration range of 0.01-80 μgmL⁻¹. The proposed method was successfully applied to the determination of letrozole in bulk, plasma and in its pharmaceutical preparation.

  7. A Double Perturbation Method for Reducing Dynamical Degradation of the Digital Baker Map

    NASA Astrophysics Data System (ADS)

    Liu, Lingfeng; Lin, Jun; Miao, Suoxia; Liu, Bocheng

    2017-06-01

    The digital Baker map is widely used in different kinds of cryptosystems, especially for image encryption. However, any chaotic map which is realized on the finite precision device (e.g. computer) will suffer from dynamical degradation, which refers to short cycle lengths, low complexity and strong correlations. In this paper, a novel double perturbation method is proposed for reducing the dynamical degradation of the digital Baker map. Both state variables and system parameters are perturbed by the digital logistic map. Numerical experiments show that the perturbed Baker map can achieve good statistical and cryptographic properties. Furthermore, a new image encryption algorithm is provided as a simple application. With a rather simple algorithm, the encrypted image can achieve high security, which is competitive to the recently proposed image encryption algorithms.

  8. A pretreatment method for HPLC analysis of cypermethrin in microbial degradation systems.

    PubMed

    Liu, Shuliang; Yao, Kai; Jia, Dongying; Zhao, Nan; Lai, Wen; Yuan, Huaiyu

    2012-07-01

    In this paper, a pretreatment method for high-performance liquid chromatography (HPLC) determination of cypermethrin (CY) in microbial degradation systems was systemically studied, primarily to solve the problem of inaccurate determination of CY concentration caused by its uneven distribution in the systems. A suitable pretreatment method was established, including sampling, extraction and dehydration of CY. Partial sampling could be taken for bacterial and yeast systems in which CY was uniformly dispersed by an emulsifying agent, while total sampling was only suitable for mold systems with or without an emulsifying agent. CY could be fully extracted from the samples in which microbial cells were disrupted by ultrasonic treatment with acetonitrile under ultrasonic condition. The extract could be effectively dehydrated and purified by passing it through an anhydrous Na(2)SO(4) column followed by an elution with acetonitrile. The determination of CY in the pretreated sample by HPLC showed a high precision [relative standard deviation (RSD) = 1.14%, n = 5] and a good stability over a period of five days (RSD = 1.57%, n = 5). The recoveries of CY in microbial degradation systems at three different spiked levels ranged from 95.68 to 108.09% (RSD = 0.50-5.87%, n = 5).

  9. Tandem repeat regions within the Burkholderia pseudomallei genome and their application for high resolution genotyping.

    PubMed

    U'Ren, Jana M; Schupp, James M; Pearson, Talima; Hornstra, Heidie; Friedman, Christine L Clark; Smith, Kimothy L; Daugherty, Rebecca R Leadem; Rhoton, Shane D; Leadem, Ben; Georgia, Shalamar; Cardon, Michelle; Huynh, Lynn Y; DeShazer, David; Harvey, Steven P; Robison, Richard; Gal, Daniel; Mayo, Mark J; Wagner, David; Currie, Bart J; Keim, Paul

    2007-03-30

    The facultative, intracellular bacterium Burkholderia pseudomallei is the causative agent of melioidosis, a serious infectious disease of humans and animals. We identified and categorized tandem repeat arrays and their distribution throughout the genome of B. pseudomallei strain K96243 in order to develop a genetic typing method for B. pseudomallei. We then screened 104 of the potentially polymorphic loci across a diverse panel of 31 isolates including B. pseudomallei, B. mallei and B. thailandensis in order to identify loci with varying degrees of polymorphism. A subset of these tandem repeat arrays were subsequently developed into a multiple-locus VNTR analysis to examine 66 B. pseudomallei and 21 B. mallei isolates from around the world, as well as 95 lineages from a serial transfer experiment encompassing ~18,000 generations. B. pseudomallei contains a preponderance of tandem repeat loci throughout its genome, many of which are duplicated elsewhere in the genome. The majority of these loci are composed of repeat motif lengths of 6 to 9 bp with 4 to 10 repeat units and are predominately located in intergenic regions of the genome. Across geographically diverse B. pseudomallei and B.mallei isolates, the 32 VNTR loci displayed between 7 and 28 alleles, with Nei's diversity values ranging from 0.47 and 0.94. Mutation rates for these loci are comparable (>10-5 per locus per generation) to that of the most diverse tandemly repeated regions found in other less diverse bacteria. The frequency, location and duplicate nature of tandemly repeated regions within the B. pseudomallei genome indicate that these tandem repeat regions may play a role in generating and maintaining adaptive genomic variation. Multiple-locus VNTR analysis revealed extensive diversity within the global isolate set containing B. pseudomallei and B. mallei, and it detected genotypic differences within clonal lineages of both species that were identical using previous typing methods. Given the health

  10. Validated method for determination of bromopride in human plasma by liquid chromatography--electrospray tandem mass spectrometry: application to the bioequivalence study.

    PubMed

    Nazare, P; Massaroti, P; Duarte, L F; Campos, D R; Marchioretto, M A M; Bernasconi, G; Calafatti, S; Barros, F A P; Meurer, E C; Pedrazzoli, J; Moraes, L A B

    2005-09-01

    A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method for the quantification of bromopride I in human plasma is presented. Sample preparation consisted of the addition of procainamide II as the internal standard, liquid-liquid extraction in alkaline conditions using hexane-ethyl acetate (1 : 1, v/v) as the extracting solvent, followed by centrifugation, evaporation of the solvent and sample reconstitution in acetonitrile. Both I and II (internal standard, IS) were analyzed using a C18 column and the mobile-phase acetonitrile-water (formic acid 0.1%). The eluted compounds were monitored using electrospray tandem mass spectrometry. The analyses were carried out by multiple reaction monitoring (MRM) using the parent-to-daughter combinations of m/z 344.20 > 271.00 and m/z 236.30 > 163.10. The areas of peaks from analyte and IS were used for quantification of I. The achieved limit of quantification was 1.0 ng/ml and the assay exhibited a linear dynamic range of 1-100.0 ng/ml and gave a correlation coefficient (r) of 0.995 or better. Validation results on linearity, specificity, accuracy, precision and stability, as well as application to the analysis of samples taken up to 24 h after oral administration of 10 mg of I in healthy volunteers demonstrated the applicability to bioequivalence studies.

  11. A dilute-and-shoot flow-injection tandem mass spectrometry method for quantification of phenobarbital in urine.

    PubMed

    Alagandula, Ravali; Zhou, Xiang; Guo, Baochuan

    2017-01-15

    Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized. This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard. The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections. Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Base-promoted one-pot tandem reaction of 3-(1-alkynyl)chromones under microwave irradiation to functionalized amino-substituted xanthones.

    PubMed

    Liu, Yang; Huang, Liping; Xie, Fuchun; Hu, Youhong

    2010-09-17

    A base-promoted one-pot tandem reaction has been developed from 3-(1-alkynyl)chromones with various acetonitriles to afford functionalized amino-substituted xanthones 3 under microwave irradiation. This tandem process involves multiple reactions, such as Michael addition/cyclization/1,2-addition, without a transition metal catalyst. This method provides an efficient approach to build up natural product-like diversified amino-substituted xanthone scaffolds rapidly.

  13. Monitoring Bilingualism: Pedagogical Implications of the Bilingual Tandem Analyser

    ERIC Educational Resources Information Center

    Schwienhorst, Klaus; Borgia, Alexandre

    2006-01-01

    Tandem learning is the collaborative learning partnership of two language learners with complementary language combinations, for example an Irish student learning German and a German student learning English. One of the major principles in tandem learning, apart from reciprocity and learner autonomy, is balanced bilingualism. While learners may…

  14. High Performance Tandem Perovskite/Polymer Solar Cells

    NASA Astrophysics Data System (ADS)

    Liu, Yao; Bag, Monojit; Page, Zachariah; Renna, Lawrence; Kim, Paul; Choi, Jaewon; Emrick, Todd; Venkataraman, D.; Russell, Thomas

    Combining perovskites with other inorganic materials, such as copper indium gallium diselenide (CIGS) or silicon, is enabling significant improvement in solar cell device performance. Here, we demonstrate a highly efficient hybrid tandem solar cell fabricated through a facile solution deposition approach to give a perovskite front sub-cell and a polymer:fullerene blend back sub-cell. This methodology eliminates the adverse effects of thermal annealing during perovskite fabrication on polymer solar cells. The record tandem solar cell efficiency of 15.96% is 40% greater than the corresponding perovskite-based single junction device and 65% greater than the polymer-based single junction device, while mitigating deleterious hysteresis effects often associated with perovskite solar cells. The hybrid tandem devices demonstrate the synergistic effects arising from the combination of perovskite and polymer-based materials for solar cells. This work was supported by the Department of Energy-supported Energy Frontier Research Center at the University of Massachusetts (DE-SC0001087). The authors acknowledge the W.M. Keck Electron Microscopy.

  15. Multiresidue analysis of pesticides in straw roughage by liquid chromatography - tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    A multiresidue analytical method using a modification of the “quick, easy, cheap, effective, rugged, and safe” (QuEChERS) sample preparation approach combined with liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis was established and validated for the rapid determination of 69 pesti...

  16. [Determination of four bisphenolic compounds in drinking water by liquid chromatography-tandem mass spectrometry].

    PubMed

    Hu, Xiaojian; Zhang, Haijing; Wang, Xiaohong; Ding, Changming; Lin, Shaobin

    2015-05-01

    To simultaneously determine the four bisphenolic compounds (bisphenol F, bisphenol A, tetrachlorobisphenol A and tetrabromobisphenol A) in drinking water by liquid chromatography tandem mass spectrometry. 200 ml water sample was extracted by solid-phase extraction, eluted with methanol and analyzed by liquid chromatography tandem mass spectrometry under the MRM mode. The separation was carried out on a T3 column (2.1 mm x 150 mm, 3 μm). The limits of detection for the four bisphenolic compounds were in the range of 0.20 - 5.5 ng/L. The mean recoveries at the two spiked levels were 87.1% - 109.0% with the intra-day precision between 6.3% - 12.4% and inter-day precision between 4.5% - 15.4%. The method was applied for determination of 15 water samples. The method was sensitive, precise and accurate.

  17. rTANDEM, an R/Bioconductor package for MS/MS protein identification.

    PubMed

    Fournier, Frédéric; Joly Beauparlant, Charles; Paradis, René; Droit, Arnaud

    2014-08-01

    rTANDEM is an R/Bioconductor package that interfaces the X!Tandem protein identification algorithm. The package can run the multi-threaded algorithm on proteomic data files directly from R. It also provides functions to convert search parameters and results to/from R as well as functions to manipulate parameters and automate searches. An associated R package, shinyTANDEM, provides a web-based graphical interface to visualize and interpret the results. Together, those two packages form an entry point for a general MS/MS-based proteomic pipeline in R/Bioconductor. rTANDEM and shinyTANDEM are distributed in R/Bioconductor, http://bioconductor.org/packages/release/bioc/. The packages are under open licenses (GPL-3 and Artistice-1.0). frederic.fournier@crchuq.ulaval.ca or arnaud.droit@crchuq.ulaval.ca Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  18. Reduction of matrix effects and improvement of sensitivity during determination of two chloridazon degradation products in aqueous matrices by using UPLC-ESI-MS/MS.

    PubMed

    Kowal, Sebastian; Balsaa, Peter; Werres, Friedrich; Schmidt, Torsten C

    2012-06-01

    The development and validation of a sensitive and reliable detection method for the determination of two polar degradation products, desphenyl-chloridazon (DPC) and methyl-desphenyl-chloridazon (MDPC) in surface water, ground water and drinking water is presented. The method is based on direct large volume injection ultra-performance liquid chromatography electrospray tandem mass spectrometry. This simple but powerful analytical method for polar substances in the aquatic environment is usually hampered by varying matrix effects, depending on the nature of different water bodies. For the two examined degradation products, the matrix effects are particularly strong compared with other polar degradation products of pesticides. Therefore, matrix effects were studied thoroughly with the aim of minimising them and improving sensitivity during determination by postcolumn addition of ammonia solution as a modifier. An internal standard was used in order to compensate for remaining matrix effects. The calibration curve shows very good coefficients of correlation (0.9994 for DPC and 0.9999 for MDPC). Intraday precision values were lower than 5 % for DPC, 3 % for MDPC and the limits of detection were 10 ng/L for both substances. The method was successfully used in a national round robin test with a deviation between 3 and 8 % from target values. Finally, about 1,000 samples from different water bodies have been examined with this method in the Rhine and Ruhr region of North-Rhine-Westphalia (Germany) and in the European Union. Approximately 76 % of analysed samples contained measurable amounts of DPC at concentrations up to 8 μg/L while 53 % of the samples showed MDPC concentrations up to 2.3 μg/L.

  19. Determination of Glyphosate, its Degradation Product Aminomethylphosphonic Acid, and Glufosinate, in Water by Isotope Dilution and Online Solid-Phase Extraction and Liquid Chromatography/Tandem Mass Spectrometry

    USGS Publications Warehouse

    Meyer, Michael T.; Loftin, Keith A.; Lee, Edward A.; Hinshaw, Gary H.; Dietze, Julie E.; Scribner, Elisabeth A.

    2009-01-01

    The U.S. Geological Survey method (0-2141-09) presented is approved for the determination of glyphosate, its degradation product aminomethylphosphonic acid (AMPA), and glufosinate in water. It was was validated to demonstrate the method detection levels (MDL), compare isotope dilution to standard addition, and evaluate method and compound stability. The original method USGS analytical method 0-2136-01 was developed using liquid chromatography/mass spectrometry and quantitation by standard addition. Lower method detection levels and increased specificity were achieved in the modified method, 0-2141-09, by using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The use of isotope dilution for glyphosate and AMPA and pseudo isotope dilution of glufosinate in place of standard addition was evaluated. Stable-isotope labeled AMPA and glyphosate were used as the isotope dilution standards. In addition, the stability of glyphosate and AMPA was studied in raw filtered and derivatized water samples. The stable-isotope labeled glyphosate and AMPA standards were added to each water sample and the samples then derivatized with 9-fluorenylmethylchloroformate. After derivatization, samples were concentrated using automated online solid-phase extraction (SPE) followed by elution in-line with the LC mobile phase; the compounds separated and then were analyzed by LC/MS/MS using electrospray ionization in negative-ion mode with multiple-reaction monitoring. The deprotonated derivatized parent molecule and two daughter-ion transition pairs were identified and optimized for glyphosate, AMPA, glufosinate, and the glyphosate and AMPA stable-isotope labeled internal standards. Quantitative comparison between standard addition and isotope dilution was conducted using 473 samples analyzed between April 2004 and June 2006. The mean percent difference and relative standard deviation between the two quantitation methods was 7.6 plus or minus 6.30 (n = 179), AMPA 9.6 plus or minus 8

  20. Semi-transparent perovskite solar cells for tandems with silicon and CIGS

    DOE PAGES

    Bailie, Colin D.; Christoforo, M. Greyson; Mailoa, Jonathan P.; ...

    2014-12-23

    A promising approach for upgrading the performance of an established low-bandgap solar technology without adding much cost is to deposit a high bandgap polycrystalline semiconductor on top to make a tandem solar cell. We use a transparent silver nanowire electrode on perovskite solar cells to achieve a semi-transparent device. We place the semi-transparent cell in a mechanically-stacked tandem configuration onto copper indium gallium diselenide (CIGS) and low-quality multicrystalline silicon (Si) to achieve solid-state polycrystalline tandem solar cells with a net improvement in efficiency over the bottom cell alone. Furthermore, this work paves the way for integrating perovskites into a low-costmore » and high-efficiency (>25%) tandem cell.« less

  1. Comparison between Two Linear Supervised Learning Machines' Methods with Principle Component Based Methods for the Spectrofluorimetric Determination of Agomelatine and Its Degradants.

    PubMed

    Elkhoudary, Mahmoud M; Naguib, Ibrahim A; Abdel Salam, Randa A; Hadad, Ghada M

    2017-05-01

    Four accurate, sensitive and reliable stability indicating chemometric methods were developed for the quantitative determination of Agomelatine (AGM) whether in pure form or in pharmaceutical formulations. Two supervised learning machines' methods; linear artificial neural networks (PC-linANN) preceded by principle component analysis and linear support vector regression (linSVR), were compared with two principle component based methods; principle component regression (PCR) as well as partial least squares (PLS) for the spectrofluorimetric determination of AGM and its degradants. The results showed the benefits behind using linear learning machines' methods and the inherent merits of their algorithms in handling overlapped noisy spectral data especially during the challenging determination of AGM alkaline and acidic degradants (DG1 and DG2). Relative mean squared error of prediction (RMSEP) for the proposed models in the determination of AGM were 1.68, 1.72, 0.68 and 0.22 for PCR, PLS, SVR and PC-linANN; respectively. The results showed the superiority of supervised learning machines' methods over principle component based methods. Besides, the results suggested that linANN is the method of choice for determination of components in low amounts with similar overlapped spectra and narrow linearity range. Comparison between the proposed chemometric models and a reported HPLC method revealed the comparable performance and quantification power of the proposed models.

  2. Negative-pressure cavitation extraction for the determination of flavonoids in pigeon pea leaves by liquid chromatography-tandem mass spectrometry.

    PubMed

    Liu, Wei; Fu, Yujie; Zu, Yuangang; Kong, Yu; Zhang, Lin; Zu, Baishi; Efferth, Thomas

    2009-05-01

    A new method, namely negative-pressure cavitation extraction (NPCE), followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) is presented for the extraction and quantification of flavonoids in pigeon pea leaves. This method combines the high efficiency of NPCE and the sensitivity and accuracy of MS/MS. The influential parameters of the NPCE procedure including liquid/solid ratio, extraction time, nitrogen flow and number of extraction cycles were optimized. Under optimized conditions, the efficiency of NPCE for extracting five flavonoids was compared to microwave-assisted extraction (MAE), ultrasonic extraction (USE) and heating reflux extraction (HRE). Additionally, structural disruption to pigeon pea leaves samples with different extraction methods was investigated by scanning electron microscopy. The relative recovery with NPCE was equivalent to or higher than that with USE and obviously higher than those with MAE and HRE which are usually conducted in higher temperatures. Furthermore, because NPCE was performed with nitrogen at room temperature, the degradation and oxidation of analytes were avoided. In addition, the NPCE method was validated in terms of repeatability and reproducibility, relative standard deviation for relative recovery was lower than 5.84 and 8.83%, respectively. The method was also successfully applied for the quantification of five flavonoids in pigeon pea leaves. All these results suggest that the developed NPCE-LC-MS/MS method represents an excellent alternative for the extraction and quantification of flavonoids in other plant materials.

  3. Liquid chromatography-electrospray ionization tandem mass spectrometry and dynamic multiple reaction monitoring method for determining multiple pesticide residues in tomato.

    PubMed

    Andrade, G C R M; Monteiro, S H; Francisco, J G; Figueiredo, L A; Botelho, R G; Tornisielo, V L

    2015-05-15

    A quick and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method, using dynamic multiple reaction monitoring and a 1.8-μm particle size analytical column, was developed to determine 57 pesticides in tomato in a 13-min run. QuEChERS (quick, easy, cheap, effective, rugged, and safe) method for samples preparations and validations was carried out in compliance with EU SANCO guidelines. The method was applied to 58 tomato samples. More than 84% of the compounds investigated showed limits of detection equal to or lower than 5 mg kg(-1). A mild (<20%), medium (20-50%), and strong (>50%) matrix effect was observed for 72%, 25%, and 3% of the pesticides studied, respectively. Eighty-one percent of the pesticides showed recoveries ranging between 70% and 120%. Twelve pesticides were detected in 35 samples, all below the maximum residue levels permitted in the Brazilian legislation; 15 samples exceeded the maximum residue levels established by the EU legislation for methamidophos; and 10 exceeded limits for acephate and four for bromuconazole. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Simultaneous quantification of methiocarb and its metabolites, methiocarb sulfoxide and methiocarb sulfone, in five food products of animal origin using tandem mass spectrometry.

    PubMed

    Rahman, Md Musfiqur; Abd El-Aty, A M; Na, Tae-Woong; Park, Joon-Seong; Kabir, Md Humayun; Chung, Hyung Suk; Lee, Han Sol; Shin, Ho-Chul; Shim, Jae-Han

    2017-08-15

    A simultaneous analytical method was developed for the determination of methiocarb and its metabolites, methiocarb sulfoxide and methiocarb sulfone, in five livestock products (chicken, pork, beef, table egg, and milk) using liquid chromatography-tandem mass spectrometry. Due to the rapid degradation of methiocarb and its metabolites, a quick sample preparation method was developed using acetonitrile and salts followed by purification via dispersive- solid phase extraction (d-SPE). Seven-point calibration curves were constructed separately in each matrix, and good linearity was observed in each matrix-matched calibration curve with a coefficient of determination (R 2 ) ≥ 0.991. The limits of detection and quantification were 0.0016 and 0.005mg/kg, respectively, for all tested analytes in various matrices. The method was validated in triplicate at three fortification levels (equivalent to 1, 2, and 10 times the limit of quantification) with a recovery rate ranging between 76.4-118.0% and a relative standard deviation≤10.0%. The developed method was successfully applied to market samples, and no residues of methiocarb and/or its metabolites were observed in the tested samples. In sum, this method can be applied for the routine analysis of methiocarb and its metabolites in foods of animal origins. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Economic viability of thin-film tandem solar modules in the United States

    NASA Astrophysics Data System (ADS)

    Sofia, Sarah E.; Mailoa, Jonathan P.; Weiss, Dirk N.; Stanbery, Billy J.; Buonassisi, Tonio; Peters, I. Marius

    2018-05-01

    Tandem solar cells are more efficient but more expensive per unit area than established single-junction (SJ) solar cells. To understand when specific tandem architectures should be utilized, we evaluate the cost-effectiveness of different II-VI-based thin-film tandem solar cells and compare them to the SJ subcells. Levelized cost of electricity (LCOE) and energy yield are calculated for four technologies: industrial cadmium telluride and copper indium gallium selenide, and their hypothetical two-terminal (series-connected subcells) and four-terminal (electrically independent subcells) tandems, assuming record SJ quality subcells. Different climatic conditions and scales (residential and utility scale) are considered. We show that, for US residential systems with current balance-of-system costs, the four-terminal tandem has the lowest LCOE because of its superior energy yield, even though it has the highest US per watt (US W-1) module cost. For utility-scale systems, the lowest LCOE architecture is the cadmium telluride single junction, the lowest US W-1 module. The two-terminal tandem requires decreased subcell absorber costs to reach competitiveness over the four-terminal one.

  6. Charge exchange cooling in the tandem mirror plasma confinement apparatus

    DOEpatents

    Logan, B. Grant

    1978-01-01

    Method and apparatus for cooling a plasma of warm charged species confined in the center mirror cell of the tandem mirror apparatus by injecting cold neutral species of the plasma into at least one mirroring region of the center mirror cell, the cooling due to the loss of warm charged species through charge exchange with the cold neutral species with resulting diffusion of the warm neutral species out of the plasma.

  7. Development and validation of a multiclass method for the quantification of veterinary drug residues in honey and royal jelly by liquid chromatography-tandem mass spectrometry.

    PubMed

    Jin, Yue; Zhang, Jinzhen; Zhao, Wen; Zhang, Wenwen; Wang, Lin; Zhou, Jinhui; Li, Yi

    2017-04-15

    The aim of this study was to develop an analytical method for the analysis of a wide range of veterinary drugs in honey and royal jelly. A modified sample preparation procedure based on the quick, easy, cheap, effective, rugged and safe (QuEChERS) method was developed, followed by liquid chromatography tandem mass spectrometry determination. Use of the single sample preparation method for analysis of 42 veterinary drugs becomes more valuable because honey and royal jelly belong to completely different complex matrices. Another main advantage of the proposed method is its ability to identify and quantify 42 veterinary drugs with higher sensitivity than reference methods of China. This work has shown that the reported method was demonstrated to be convenient and reliable for the quick monitoring of veterinary drugs in honey and royal jelly samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Graphene-Based Linear Tandem Micro-Supercapacitors with Metal-Free Current Collectors and High-Voltage Output.

    PubMed

    Shi, Xiaoyu; Wu, Zhong-Shuai; Qin, Jieqiong; Zheng, Shuanghao; Wang, Sen; Zhou, Feng; Sun, Chenglin; Bao, Xinhe

    2017-11-01

    Printable supercapacitors are regarded as a promising class of microscale power source, but are facing challenges derived from conventional sandwich-like geometry. Herein, the printable fabrication of new-type planar graphene-based linear tandem micro-supercapacitors (LTMSs) on diverse substrates with symmetric and asymmetric configuration, high-voltage output, tailored capacitance, and outstanding flexibility is demonstrated. The resulting graphene-based LTMSs consisting of 10 micro-supercapacitors (MSs) present efficient high-voltage output of 8.0 V, suggestive of superior uniformity of the entire integrated device. Meanwhile, LTMSs possess remarkable flexibility without obvious capacitance degradation under different bending states. Moreover, areal capacitance of LTMSs can be sufficiently modulated by incorporating polyaniline-based pseudocapacitive nanosheets into graphene electrodes, showing enhanced capacitance of 7.6 mF cm -2 . To further improve the voltage output and energy density, asymmetric LTMSs are fabricated through controlled printing of linear-patterned graphene as negative electrodes and MnO 2 nanosheets as positive electrodes. Notably, the asymmetric LTMSs from three serially connected MSs are easily extended to 5.4 V, triple voltage output of the single cell (1.8 V), suggestive of the versatile applicability of this technique. Therefore, this work offers numerous opportunities of graphene and analogous nanosheets for one-step scalable fabrication of flexible tandem energy storage devices integrating with printed electronics on same substrate. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Typing Clostridium difficile strains based on tandem repeat sequences

    PubMed Central

    2009-01-01

    Background Genotyping of epidemic Clostridium difficile strains is necessary to track their emergence and spread. Portability of genotyping data is desirable to facilitate inter-laboratory comparisons and epidemiological studies. Results This report presents results from a systematic screen for variation in repetitive DNA in the genome of C. difficile. We describe two tandem repeat loci, designated 'TR6' and 'TR10', which display extensive sequence variation that may be useful for sequence-based strain typing. Based on an investigation of 154 C. difficile isolates comprising 75 ribotypes, tandem repeat sequencing demonstrated excellent concordance with widely used PCR ribotyping and equal discriminatory power. Moreover, tandem repeat sequences enabled the reconstruction of the isolates' largely clonal population structure and evolutionary history. Conclusion We conclude that sequence analysis of the two repetitive loci introduced here may be highly useful for routine typing of C. difficile. Tandem repeat sequence typing resolves phylogenetic diversity to a level equivalent to PCR ribotypes. DNA sequences may be stored in databases accessible over the internet, obviating the need for the exchange of reference strains. PMID:19133124

  10. Method development for quantification of quizartinib in rat plasma by liquid chromatography/tandem mass spectrometry for pharmacokinetic application.

    PubMed

    Ezzeldin, Essam; Iqbal, Muzaffar; Mostafa, Gamal; Al-Rashood, Khalid A; El-Nahhas, Toqa

    2018-03-01

    Quizartinib is a highly potent inhibitor of the fms-like tyrosine kinase receptor, which is one of the most commonly mutated genes in acute myeloid leukemia. Quizartinib has shown a significant antileukemic clinical influence among relapsed/refractory acute myeloid leukemia patients. This study aimed at developing and validating an analytical method for the measurement of quizartinib in rat plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was validated according to US Food and Drug Administration guidelines, and the results obtained in this work met the set criteria. Liquid-liquid extraction was used and chromatographic separation was achieved on a BEHTM C 18 column. Detection of quizartinib was achieved in multiple reaction monitoring mode using positive-ion mode electrospray ionization. The MS/MS ion transitions at mass-to-charge ratios (m/z) of 561.129/114.09 and 441.16/84.03 were monitored for quizartinib and ibrutinib, respectively. The linear detection range was 2-1000 ng/mL (r > 0.998), with intra- and inter-day assay precisions ≤13.07 and 13.17%, respectively. This rapid, simple and sensitive method was validated and successfully applied to the pharmacokinetic study of quizartinib in rat samples. Copyright © 2017 John Wiley & Sons, Ltd.

  11. Development of a novel method for quantification of autophagic protein degradation by AHA labeling.

    PubMed

    Zhang, Jianbin; Wang, Jigang; Ng, Shukie; Lin, Qingsong; Shen, Han-Ming

    2014-05-01

    Autophagy is a catabolic process during which cellular components including protein aggregates and organelles are degraded via a lysosome-dependent process to sustain metabolic homeostasis during nutrient or energy deprivation. Measuring the rate of proteolysis of long-lived proteins is a classical assay for measurement of autophagic flux. However, traditional methods, such as a radioisotope labeling assay, are technically tedious and have low sensitivity. Here, we report a novel method for quantification of long-lived protein degradation based on L-azidohomoalanine (AHA) labeling in mouse embryonic fibroblasts (MEFs) and in human cancer cells. AHA is a surrogate for L-methionine, containing a bio-orthogonalazide moiety. When added to cultured cells, AHA is incorporated into proteins during active protein synthesis. After a click reaction between an azide and an alkyne, the azide-containing proteins can be detected with an alkyne-tagged fluorescent dye, coupled with flow cytometry. Induction of autophagy by starvation or mechanistic target of rapamycin (MTOR) inhibitors was able to induce a significant reduction of the fluorescence intensity, consistent with other autophagic markers. Coincidently, inhibition of autophagy by pharmacological agents or by Atg gene deletion abolished the reduction of the fluorescence intensity. Compared with the classical radioisotope pulse-labeling method, we think that our method is sensitive, quantitative, nonradioactive, and easy to perform, and can be applied to both human and animal cell culture systems.

  12. Development of a novel method for quantification of autophagic protein degradation by AHA labeling

    PubMed Central

    Zhang, Jianbin; Wang, Jigang; Ng, Shukie; Lin, Qingsong; Shen, Han-Ming

    2014-01-01

    Autophagy is a catabolic process during which cellular components including protein aggregates and organelles are degraded via a lysosome-dependent process to sustain metabolic homeostasis during nutrient or energy deprivation. Measuring the rate of proteolysis of long-lived proteins is a classical assay for measurement of autophagic flux. However, traditional methods, such as a radioisotope labeling assay, are technically tedious and have low sensitivity. Here, we report a novel method for quantification of long-lived protein degradation based on L-azidohomoalanine (AHA) labeling in mouse embryonic fibroblasts (MEFs) and in human cancer cells. AHA is a surrogate for L-methionine, containing a bio-orthogonalazide moiety. When added to cultured cells, AHA is incorporated into proteins during active protein synthesis. After a click reaction between an azide and an alkyne, the azide-containing proteins can be detected with an alkyne-tagged fluorescent dye, coupled with flow cytometry. Induction of autophagy by starvation or mechanistic target of rapamycin (MTOR) inhibitors was able to induce a significant reduction of the fluorescence intensity, consistent with other autophagic markers. Coincidently, inhibition of autophagy by pharmacological agents or by Atg gene deletion abolished the reduction of the fluorescence intensity. Compared with the classical radioisotope pulse-labeling method, we think that our method is sensitive, quantitative, nonradioactive, and easy to perform, and can be applied to both human and animal cell culture systems. PMID:24675368

  13. Solution-processed parallel tandem polymer solar cells using silver nanowires as intermediate electrode.

    PubMed

    Guo, Fei; Kubis, Peter; Li, Ning; Przybilla, Thomas; Matt, Gebhard; Stubhan, Tobias; Ameri, Tayebeh; Butz, Benjamin; Spiecker, Erdmann; Forberich, Karen; Brabec, Christoph J

    2014-12-23

    Tandem architecture is the most relevant concept to overcome the efficiency limit of single-junction photovoltaic solar cells. Series-connected tandem polymer solar cells (PSCs) have advanced rapidly during the past decade. In contrast, the development of parallel-connected tandem cells is lagging far behind due to the big challenge in establishing an efficient interlayer with high transparency and high in-plane conductivity. Here, we report all-solution fabrication of parallel tandem PSCs using silver nanowires as intermediate charge collecting electrode. Through a rational interface design, a robust interlayer is established, enabling the efficient extraction and transport of electrons from subcells. The resulting parallel tandem cells exhibit high fill factors of ∼60% and enhanced current densities which are identical to the sum of the current densities of the subcells. These results suggest that solution-processed parallel tandem configuration provides an alternative avenue toward high performance photovoltaic devices.

  14. Study of series-connected polymer tandem solar cells based on a highly efficient donor material of PTB7-Th

    NASA Astrophysics Data System (ADS)

    Zang, Yue; Gao, Xiumin; Xin, Qing; Lin, Jun; Zhao, Jufeng

    2017-06-01

    A highly efficient donor polymer, PTB7-Th, combined with acceptor fullerene PC71BM was introduced as the subcell in the series-connected tandem devices to achieve high-performance polymer tandem solar cells. Design of the device architecture was investigated using modeling and simulation methods to identify the optimal structure and to predict performance of the tandem cells. To address the challenge of current matching between the constituent subcells, the effect of active layer thickness, different device structure, and use of ultrathin Ag film were analyzed. It was found that the distribution of optical intensity in the tandem structure can be optimized through the optical spacer effect of interfacial layers and micro-cavity effect derived from the embedded ultrathin Ag film. Our results indicate that the efficient light utilization with appropriate subcells can allow achievement of power conversion efficiency of 12%, which can be 25% higher than that of a single cell of PTB7-Th.

  15. Determination of tiropramide in human plasma by liquid chromatography-tandem mass spectrometry.

    PubMed

    Lee, Hye Won; Ji, Hye Young; Kim, Hee Hyun; Cho, Hea-Young; Lee, Yong-Bok; Lee, Hye Suk

    2003-11-05

    A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.

  16. Tandem Repeated Irritation Test (TRIT) Studies and Clinical Relevance: Post 2006.

    PubMed

    Reddy, Rasika; Maibach, Howard

    2018-06-11

    Single or multiple applications of irritants can lead to occupational contact dermatitis, and most commonly irritant contact dermatitis (ICD). Tandem irritation, the sequential application of two irritants to a target skin area, has been studied using the Tandem Repeated Irritation Test (TRIT) to provide a more accurate representation of skin irritation. Here we present an update to Kartono's review on tandem irritation studies since 2006 [1]. We surveyed the literature available on PubMed, Embase, Google Scholar, and the UCSF Dermatology library databases since 2006. The studies included discuss the tandem effects of common chemical irritants, organic solvents, occlusion as well as clinical relevance - and enlarge our ability to discern whether multiple chemical exposures are more or less likely to enhance irritation.

  17. Laboratory Test Methods to Determine the Degradation of Plastics in Marine Environmental Conditions

    PubMed Central

    Tosin, Maurizio; Weber, Miriam; Siotto, Michela; Lott, Christian; Degli Innocenti, Francesco

    2012-01-01

    In this technology report, three test methods were developed to characterize the degradation of plastic in marine environment. The aim was to outline a test methodology to measure the physical and biological degradation in different habitats where plastic waste can deposit when littered in the sea. Previously, research has focused mainly on the conditions encountered by plastic items when floating in the sea water (pelagic domain). However, this is just one of the possible habitats that plastic waste can be exposed to. Waves and tides tend to wash up plastic waste on the shoreline, which is also a relevant habitat to be studied. Therefore, the degradation of plastic items buried under sand kept wet with sea water has been followed by verifying the disintegration (visual disappearing) as a simulation of the tidal zone. Most biodegradable plastics have higher densities than water and also as a consequence of fouling, they tend to sink and lay on the sea floor. Therefore, the fate of plastic items lying on the sediment has been followed by monitoring the oxygen consumption (biodegradation). Also the effect of a prolonged exposure to the sea water, to simulate the pelagic domain, has been tested by measuring the decay of mechanical properties. The test material (Mater-Bi) was shown to degrade (total disintegration achieved in less than 9 months) when buried in wet sand (simulation test of the tidal zone), to lose mechanical properties but still maintain integrity (tensile strength at break = −66% in 2 years) when exposed to sea water in an aquarium (simulation of pelagic domain), and substantially biodegrade (69% in 236 days; biodegradation relative to paper: 88%) when located at the sediment/sea water interface (simulation of benthic domain). This study is not conclusive as the methodological approach must be completed by also determining degradation occurring in the supralittoral zone, on the deep sea floor, and in the anoxic sediment. PMID:22737147

  18. Laboratory test methods to determine the degradation of plastics in marine environmental conditions.

    PubMed

    Tosin, Maurizio; Weber, Miriam; Siotto, Michela; Lott, Christian; Degli Innocenti, Francesco

    2012-01-01

    In this technology report, three test methods were developed to characterize the degradation of plastic in marine environment. The aim was to outline a test methodology to measure the physical and biological degradation in different habitats where plastic waste can deposit when littered in the sea. Previously, research has focused mainly on the conditions encountered by plastic items when floating in the sea water (pelagic domain). However, this is just one of the possible habitats that plastic waste can be exposed to. Waves and tides tend to wash up plastic waste on the shoreline, which is also a relevant habitat to be studied. Therefore, the degradation of plastic items buried under sand kept wet with sea water has been followed by verifying the disintegration (visual disappearing) as a simulation of the tidal zone. Most biodegradable plastics have higher densities than water and also as a consequence of fouling, they tend to sink and lay on the sea floor. Therefore, the fate of plastic items lying on the sediment has been followed by monitoring the oxygen consumption (biodegradation). Also the effect of a prolonged exposure to the sea water, to simulate the pelagic domain, has been tested by measuring the decay of mechanical properties. The test material (Mater-Bi) was shown to degrade (total disintegration achieved in less than 9 months) when buried in wet sand (simulation test of the tidal zone), to lose mechanical properties but still maintain integrity (tensile strength at break = -66% in 2 years) when exposed to sea water in an aquarium (simulation of pelagic domain), and substantially biodegrade (69% in 236 days; biodegradation relative to paper: 88%) when located at the sediment/sea water interface (simulation of benthic domain). This study is not conclusive as the methodological approach must be completed by also determining degradation occurring in the supralittoral zone, on the deep sea floor, and in the anoxic sediment.

  19. A quantitative liquid chromatography tandem mass spectrometry method for metabolomic analysis of Plasmodium falciparum lipid related metabolites.

    PubMed

    Vo Duy, S; Besteiro, S; Berry, L; Perigaud, C; Bressolle, F; Vial, H J; Lefebvre-Tournier, I

    2012-08-20

    Plasmodium falciparum is the causative agent of malaria, a deadly infectious disease for which treatments are scarce and drug-resistant parasites are now increasingly found. A comprehensive method of identifying and quantifying metabolites of this intracellular parasite could expand the arsenal of tools to understand its biology, and be used to develop new treatments against the disease. Here, we present two methods based on liquid chromatography tandem mass spectrometry for reliable measurement of water-soluble metabolites involved in phospholipid biosynthesis, as well as several other metabolites that reflect the metabolic status of the parasite including amino acids, carboxylic acids, energy-related carbohydrates, and nucleotides. A total of 35 compounds was quantified. In the first method, polar compounds were retained by hydrophilic interaction chromatography (amino column) and detected in negative mode using succinic acid-(13)C(4) and fluorovaline as internal standards. In the second method, separations were carried out using reverse phase (C18) ion-pair liquid chromatography, with heptafluorobutyric acid as a volatile ion pairing reagent in positive detection mode, using d(9)-choline and 4-aminobutanol as internal standards. Standard curves were performed in P. falciparum-infected and uninfected red blood cells using standard addition method (r(2)>0.99). The intra- and inter-day accuracy and precision as well as the extraction recovery of each compound were determined. The lower limit of quantitation varied from 50pmol to 100fmol/3×10(7)cells. These methods were validated and successfully applied to determine intracellular concentrations of metabolites from uninfected host RBCs and isolated Plasmodium parasites. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Enhanced degradation of Herbicide Isoproturon in wheat rhizosphere by salicylic acid.

    PubMed

    Lu, Yi Chen; Zhang, Shuang; Miao, Shan Shan; Jiang, Chen; Huang, Meng Tian; Liu, Ying; Yang, Hong

    2015-01-14

    This study investigated the herbicide isoproturon (IPU) residues in soil, where wheat was cultivated and sprayed with salicylic acid (SA). Provision of SA led to a lower level of IPU residues in rhizosphere soil compared to IPU treatment alone. Root exudation of tartaric acid, malic acid, and oxalic acids was enhanced in rhizosphere soil with SA-treated wheat. We examined the microbial population (e.g., biomass and phospholipid fatty acid), microbial structure, and soil enzyme (catalase, phenol oxidase, and dehydrogenase) activities, all of which are associated with soil activity and were activated in rhizosphere soil of SA-treated wheat roots. We further assessed the correlation matrix and principal component to figure out the association between the IPU degradation and soil activity. Finally, six IPU degraded products (derivatives) in rhizosphere soil were characterized using ultraperformance liquid chromatography with a quadrupole-time-of-flight tandem mass spectrometer (UPLC/Q-TOF-MS/MS). A relatively higher level of IPU derivatives was identified in soil with SA-treated wheat than in soil without SA-treated wheat plants.

  1. SU-D-BRF-05: A Novel System to Provide Real-Time Image-Guidance for Intrauterine Tandem Insertion and Placement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, M; Fontenot, J

    Purpose: To develop a system that provides real-time image-guidance for intrauterine tandem insertion and placement for brachytherapy. Methods: The conceptualized system consists of an intrauterine tandem with a transparent, lensed tip, a flexible miniature fiber optic scope, light source and interface for CCD coupling. The tandem tip was designed to act as a lens providing a wide field-of-view (FOV) with minimal image distortion and focus length appropriate for the application. The system is designed so that once inserted, the image-guidance component of the system can be removed and brachytherapy can be administered without interfering with source transport or disturbing tandemmore » placement. Proof-of-principle studies were conducted to assess the conceptualized system's (1) lens functionality (clarity, focus and FOV) (2) and ability to visualize the cervical os of a female placed in the lithotomy position. Results: A prototype of this device was constructed using a commercial tandem modified to incorporate a transparent tip that internally coupled with a 1.9mm diameter fiber optic cable. The 900mm-long cable terminated at an interface that provided illumination as well as facilitated visualization of patient anatomy on a computer. The system provided a 23mm FOV with a focal length of 1cm and provided clear visualization of the cervix, cervical fornix and cervical os. The optical components of the system are easily removed without perturbing the position of a tandem placed in a common fixation clamp. Conclusion: Clinicians frequently encounter difficulty inserting an intrauterine tandem through the cervical os, circumventing fibrotic tissue or masses within the uterus, and positioning the tandem without perforating the uterus. To mitigate these challenges, we have designed and conducted proof-of- principle studies to discern the utility of a prototype device that provides real-time image-guidance for intrauterine tandem placement using fiber optic components.« less

  2. Flow field interactions between two tandem cyclists

    NASA Astrophysics Data System (ADS)

    Barry, Nathan; Burton, David; Sheridan, John; Thompson, Mark; Brown, Nicholas A. T.

    2016-12-01

    Aerodynamic drag is the primary resistive force acting on cyclists at racing speeds. Many events involve cyclists travelling in very close proximity. Previous studies have shown that interactions result in significant drag reductions for inline cyclists. However, the interaction between cyclist leg position (pedalling) and the vortical flow structures that contribute significantly to the drag on an isolated cyclist has not previously been quantified or described for tandem cyclists of varying separation. To this end, scale model cyclists were constructed for testing in a water channel for inline tandem configurations. Particle image velocimetry was used to capture time-averaged velocity fields around two tandem cyclists. Perhaps surprisingly, the wake of a trailing cyclist maintains strong similarity to the characteristic wake of a single cyclist despite a significant disturbance to the upstream flow. Together with streamwise velocity measurements through the wake and upstream of the trailing cyclist, this work supports previous findings, which showed that the trailing cyclist drag reduction is primarily due to upstream sheltering effects reducing the stagnation pressure on forward-facing surfaces.

  3. Stacking multiple connecting functional materials in tandem organic light-emitting diodes

    NASA Astrophysics Data System (ADS)

    Zhang, Tao; Wang, Deng-Ke; Jiang, Nan; Lu, Zheng-Hong

    2017-02-01

    Tandem device is an important architecture in fabricating high performance organic light-emitting diodes and organic photovoltaic cells. The key element in making a high performance tandem device is the connecting materials stack, which plays an important role in electric field distribution, charge generation and charge injection. For a tandem organic light-emitting diode (OLED) with a simple Liq/Al/MoO3 stack, we discovered that there is a significant current lateral spreading causing light emission over an extremely large area outside the OLED pixel when the Al thickness exceeds 2 nm. This spread light emission, caused by an inductive electric field over one of the device unit, limits one’s ability to fabricate high performance tandem devices. To resolve this issue, a new connecting materials stack with a C60 fullerene buffer layer is reported. This new structure permits optimization of the Al metal layer in the connecting stack and thus enables us to fabricate an efficient tandem OLED having a high 155.6 cd/A current efficiency and a low roll-off (or droop) in current efficiency.

  4. Development of a Novel Multipenicillin Assay and Assessment of the Impact of Analyte Degradation: Lessons for Scavenged Sampling in Antimicrobial Pharmacokinetic Study Design.

    PubMed

    Kipper, Karin; Barker, Charlotte I S; Standing, Joseph F; Sharland, Mike; Johnston, Atholl

    2018-01-01

    Penicillins are widely used to treat infections in children; however, the evidence is continuing to evolve in defining the optimal dosing. Modern pediatric pharmacokinetic study protocols frequently favor opportunistic, "scavenged" sampling. This study aimed to develop a small-volume single assay for five major penicillins and to assess the influence of sample degradation on inferences made using pharmacokinetic modeling, to investigate the suitability of scavenged sampling strategies. Using a rapid ultrahigh-performance liquid chromatographic-tandem mass spectrometric method, an assay for five penicillins (amoxicillin, ampicillin, benzylpenicillin, piperacillin, and flucloxacillin) in blood plasma was developed and validated. Penicillin stabilities were evaluated under different conditions. Using these data, the impact of drug degradation on inferences made during pharmacokinetic modeling was evaluated. All evaluated penicillins indicated good stability at room temperature (23 ± 2°C) over 1 h, remaining in the range of 98 to 103% of the original concentration. More-rapid analyte degradation had already occurred after 4 h, with stability ranging from 68% to 99%. Stability over longer periods declined: degradation of up to 60% was observed with delayed sample processing of up to 24 h. Modeling showed that analyte degradation can lead to a 30% and 28% bias in clearance and volume of distribution, respectively, and falsely show nonlinearity in clearance. Five common penicillins can now be measured in a single low-volume blood sample. Beta-lactam chemical instability in plasma can cause misleading pharmacokinetic modeling results, which could impact upon model-based dosing recommendations and the forthcoming era of beta-lactam therapeutic drug monitoring. Copyright © 2017 American Society for Microbiology.

  5. Identification and High-Resolution Imaging of α-Tocopherol from Human Cells to Whole Animals by TOF-SIMS Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Bruinen, Anne L.; Fisher, Gregory L.; Balez, Rachelle; van der Sar, Astrid M.; Ooi, Lezanne; Heeren, Ron M. A.

    2018-06-01

    A unique method for identification of biomolecular components in different biological specimens, while preserving the capability for high speed 2D and 3D molecular imaging, is employed to investigate cellular response to oxidative stress. The employed method enables observing the distribution of the antioxidant α-tocopherol and other molecules in cellular structures via time-of-flight secondary ion mass spectrometry (TOF-SIMS (MS1)) imaging in parallel with tandem mass spectrometry (MS2) imaging, collected simultaneously. The described method is employed to examine a network formed by neuronal cells differentiated from human induced pluripotent stem cells (iPSCs), a model for investigating human neurons in vitro. The antioxidant α-tocopherol is identified in situ within different cellular layers utilizing a 3D TOF-SIMS tandem MS imaging analysis. As oxidative stress also plays an important role in mediating inflammation, the study was expanded to whole body tissue sections of M. marinum-infected zebrafish, a model organism for tuberculosis. The TOF-SIMS tandem MS imaging results reveal an increased presence of α-tocopherol in response to the pathogen. [Figure not available: see fulltext.

  6. Acceleration of the herbicide isoproturon degradation in wheat by glycosyltransferases and salicylic acid.

    PubMed

    Lu, Yi Chen; Zhang, Shuang; Yang, Hong

    2015-01-01

    Isoproturon (IPU) is a herbicide widely used to prevent weeds in cereal production. Due to its extensive use in agriculture, residues of IPU are often detected in soils and crops. Overload of IPU to crops is associated with human health risks. Hence, there is an urgent need to develop an approach to mitigate its accumulation in crops. In this study, the IPU residues and its degradation products in wheat were characterized using ultra performance liquid chromatography-time of fight tandem-mass spectrometer/mass spectrometer (UPLC-TOF-MS/MS). Most detected IPU-derivatives were sugar-conjugated. Degradation and glycosylation of IPU-derivatives could be enhanced by applying salicylic acid (SA). While more sugar-conjugated IPU-derivatives were identified in wheat with SA application, lower levels of IPU were detected, indicating that SA is able to accelerate intracellular IPU catabolism. All structures of IPU-derivatives and sugar-conjugated products were characterized. Comparative data were provided with specific activities and gene expression of certain glucosyltransferases. A pathway with IPU degradation and glucosylation was discussed. Our work indicates that SA-accelerated degradation is practically useful for wheat crops growing in IPU-contaminated soils because such crops with SA application can potentially lower or minimize IPU accumulation in levels below the threshold for adverse effects. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Analytical method development of nifedipine and its degradants binary mixture using high performance liquid chromatography through a quality by design approach

    NASA Astrophysics Data System (ADS)

    Choiri, S.; Ainurofiq, A.; Ratri, R.; Zulmi, M. U.

    2018-03-01

    Nifedipin (NIF) is a photo-labile drug that easily degrades when it exposures a sunlight. This research aimed to develop of an analytical method using a high-performance liquid chromatography and implemented a quality by design approach to obtain effective, efficient, and validated analytical methods of NIF and its degradants. A 22 full factorial design approach with a curvature as a center point was applied to optimize of the analytical condition of NIF and its degradants. Mobile phase composition (MPC) and flow rate (FR) as factors determined on the system suitability parameters. The selected condition was validated by cross-validation using a leave one out technique. Alteration of MPC affected on time retention significantly. Furthermore, an increase of FR reduced the tailing factor. In addition, the interaction of both factors affected on an increase of the theoretical plates and resolution of NIF and its degradants. The selected analytical condition of NIF and its degradants has been validated at range 1 – 16 µg/mL that had good linearity, precision, accuration and efficient due to an analysis time within 10 min.

  8. Methods and optical fibers that decrease pulse degradation resulting from random chromatic dispersion

    DOEpatents

    Chertkov, Michael; Gabitov, Ildar

    2004-03-02

    The present invention provides methods and optical fibers for periodically pinning an actual (random) accumulated chromatic dispersion of an optical fiber to a predicted accumulated dispersion of the fiber through relatively simple modifications of fiber-optic manufacturing methods or retrofitting of existing fibers. If the pinning occurs with sufficient frequency (at a distance less than or are equal to a correlation scale), pulse degradation resulting from random chromatic dispersion is minimized. Alternatively, pinning may occur quasi-periodically, i.e., the pinning distance is distributed between approximately zero and approximately two to three times the correlation scale.

  9. A new method for large-scale assessment of change in ecosystem functioning in relation to land degradation

    NASA Astrophysics Data System (ADS)

    Horion, Stephanie; Ivits, Eva; Verzandvoort, Simone; Fensholt, Rasmus

    2017-04-01

    Ongoing pressures on European land are manifold with extreme climate events and non-sustainable use of land resources being amongst the most important drivers altering the functioning of the ecosystems. The protection and conservation of European natural capital is one of the key objectives of the 7th Environmental Action Plan (EAP). The EAP stipulates that European land must be managed in a sustainable way by 2020 and the UN Sustainable development goals define a Land Degradation Neutral world as one of the targets. This implies that land degradation (LD) assessment of European ecosystems must be performed repeatedly allowing for the assessment of the current state of LD as well as changes compared to a baseline adopted by the UNCCD for the objective of land degradation neutrality. However, scientifically robust methods are still lacking for large-scale assessment of LD and repeated consistent mapping of the state of terrestrial ecosystems. Historical land degradation assessments based on various methods exist, but methods are generally non-replicable or difficult to apply at continental scale (Allan et al. 2007). The current lack of research methods applicable at large spatial scales is notably caused by the non-robust definition of LD, the scarcity of field data on LD, as well as the complex inter-play of the processes driving LD (Vogt et al., 2011). Moreover, the link between LD and changes in land use (how land use changes relates to change in vegetation productivity and ecosystem functioning) is not straightforward. In this study we used the segmented trend method developed by Horion et al. (2016) for large-scale systematic assessment of hotspots of change in ecosystem functioning in relation to LD. This method alleviates shortcomings of widely used linear trend model that does not account for abrupt change, nor adequately captures the actual changes in ecosystem functioning (de Jong et al. 2013; Horion et al. 2016). Here we present a new methodology for

  10. DNA-based stable isotope probing coupled with cultivation methods implicates Methylophaga in hydrocarbon degradation

    PubMed Central

    Mishamandani, Sara; Gutierrez, Tony; Aitken, Michael D.

    2014-01-01

    Marine hydrocarbon-degrading bacteria perform a fundamental role in the oxidation and ultimate removal of crude oil and its petrochemical derivatives in coastal and open ocean environments. Those with an almost exclusive ability to utilize hydrocarbons as a sole carbon and energy source have been found confined to just a few genera. Here we used stable isotope probing (SIP), a valuable tool to link the phylogeny and function of targeted microbial groups, to investigate hydrocarbon-degrading bacteria in coastal North Carolina sea water (Beaufort Inlet, USA) with uniformly labeled [13C]n-hexadecane. The dominant sequences in clone libraries constructed from 13C-enriched bacterial DNA (from n-hexadecane enrichments) were identified to belong to the genus Alcanivorax, with ≤98% sequence identity to the closest type strain—thus representing a putative novel phylogenetic taxon within this genus. Unexpectedly, we also identified 13C-enriched sequences in heavy DNA fractions that were affiliated to the genus Methylophaga. This is a contentious group since, though some of its members have been proposed to degrade hydrocarbons, substantive evidence has not previously confirmed this. We used quantitative PCR primers targeting the 16S rRNA gene of the SIP-identified Alcanivorax and Methylophaga to determine their abundance in incubations amended with unlabeled n-hexadecane. Both showed substantial increases in gene copy number during the experiments. Subsequently, we isolated a strain representing the SIP-identified Methylophaga sequences (99.9% 16S rRNA gene sequence identity) and used it to show, for the first time, direct evidence of hydrocarbon degradation by a cultured Methylophaga sp. This study demonstrates the value of coupling SIP with cultivation methods to identify and expand on the known diversity of hydrocarbon-degrading bacteria in the marine environment. PMID:24578702

  11. [Polymorphic loci and polymorphism analysis of short tandem repeats within XNP gene].

    PubMed

    Liu, Qi-Ji; Gong, Yao-Qin; Guo, Chen-Hong; Chen, Bing-Xi; Li, Jiang-Xia; Guo, Yi-Shou

    2002-01-01

    To select polymorphic short tandem repeat markers within X-linked nuclear protein (XNP) gene, genomic clones which contain XNP gene were recognized by homologous analysis with XNP cDNA. By comparing the cDNA with genomic DNA, non-exonic sequences were identified, and short tandem repeats were selected from non-exonic sequences by using BCM search Launcher. Polymorphisms of the short tandem repeats in Chinese population were evaluated by PCR amplification and PAGE. Five short tandem repeats were identified from XNP gene, two of which were polymorphic. Four and 11 alleles were observed in Chinese population for XNPSTR1 and XNPSTR4, respectively. Heterozygosities were 47% for XNPSTR1 and 70% for XNPSTR4. XNPSTR1 and XNPSTR4 localized within 3' end and intron 10, respectively. Two polymorphic short tandem repeats have been identified within XNP gene and will be useful for linkage analysis and gene diagnosis of XNP gene.

  12. Low-Cost CdTe/Silicon Tandem Solar Cells

    DOE PAGES

    Tamboli, Adele C.; Bobela, David C.; Kanevce, Ana; ...

    2017-09-06

    Achieving higher photovoltaic efficiency in single-junction devices is becoming increasingly difficult, but tandem modules offer the possibility of significant efficiency improvements. By device modeling we show that four-terminal CdTe/Si tandem solar modules offer the prospect of 25%-30% module efficiency, and technoeconomic analysis predicts that these efficiency gains can be realized at costs per Watt that are competitive with CdTe and Si single junction alternatives. The cost per Watt of the modeled tandems is lower than crystalline silicon, but slightly higher than CdTe alone. But, these higher power modules reduce area-related balance of system costs, providing increased value especially in area-constrainedmore » applications. This avenue for high-efficiency photovoltaics enables improved performance on a near-term timeframe, as well as a path to further reduced levelized cost of electricity as module and cell processes continue to advance.« less

  13. Low-Cost CdTe/Silicon Tandem Solar Cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamboli, Adele C.; Bobela, David C.; Kanevce, Ana

    Achieving higher photovoltaic efficiency in single-junction devices is becoming increasingly difficult, but tandem modules offer the possibility of significant efficiency improvements. By device modeling we show that four-terminal CdTe/Si tandem solar modules offer the prospect of 25%-30% module efficiency, and technoeconomic analysis predicts that these efficiency gains can be realized at costs per Watt that are competitive with CdTe and Si single junction alternatives. The cost per Watt of the modeled tandems is lower than crystalline silicon, but slightly higher than CdTe alone. But, these higher power modules reduce area-related balance of system costs, providing increased value especially in area-constrainedmore » applications. This avenue for high-efficiency photovoltaics enables improved performance on a near-term timeframe, as well as a path to further reduced levelized cost of electricity as module and cell processes continue to advance.« less

  14. A dedicated AMS setup for medium mass isotopes at the Cologne FN tandem accelerator

    NASA Astrophysics Data System (ADS)

    Schiffer, M.; Altenkirch, R.; Feuerstein, C.; Müller-Gatermann, C.; Hackenberg, G.; Herb, S.; Bhandari, P.; Heinze, S.; Stolz, A.; Dewald, A.

    2017-09-01

    AMS measurements of medium mass isotopes, e.g. of 53Mn and 60Fe, are gaining interest in various fields of operation, especially geoscience. Therefore a dedicated AMS setup has been built at the Cologne 10 MV FN tandem accelerator. This setup is designed to obtain a sufficient suppression of the stable isobars at energies around 100 MeV. In this contribution we report on the actual status of the new setup and the first in-beam tests of its individual components. The isobar suppression is done with (dE/dx) techniques using combinations of energy degrader foils with an electrostatic analyzer (ESA) and a time of flight (ToF) system, as well as a (dE/dx),E gas ionization detector. Furthermore, the upgraded ion source and its negative ion yield measurement for MnO- are presented.

  15. Soil burial method for plastic degradation performed by Pseudomonas PL-01, Bacillus PL-01, and indigenous bacteria

    NASA Astrophysics Data System (ADS)

    Shovitri, Maya; Nafi'ah, Risyatun; Antika, Titi Rindi; Alami, Nur Hidayatul; Kuswytasari, N. D.; Zulaikha, Enny

    2017-06-01

    Lately, plastic bag is becoming the most important pollutant for environment since it is difficult to be naturally degraded due to it consists of long hydrocarbon polymer chains. Our previous study indicated that our pure isolate Pseudomonas PL-01 and Bacillus PL-01 could degrade about 10% plastic bag. This present study was aimed to find out whether Pseudomonas PL01 and Bacillus PL01 put a positive effect to indigenous bacteria from marginal area in doing plastic degradation with a soil burial method. Beach sand was used as a representative marginal area, and mangrove sediment was used as a comparison. Plastics were submerged into unsterile beach sand with 10% of Pseudomonas PL-01 or Bacillus PL-01 containing liquid minimal salt medium (MSM) separately, while other plastics were submerged into unsterile mangrove sediments. After 4, 8, 12 and 16 weeks, their biofilm formation on their plastic surfaces and plastic degradation were measured. Results indicated that those 2 isolates put positive influent on biofilm formation and plastic degradation for indigenous beach sand bacteria. Bacillus PL-01 put higher influent than Pseudomonas PL-01. Plastic transparent was preferable degraded than black and white plastic bag `kresek'. But anyhow, indigenous mangrove soil bacteria showed the best performance in biofilm formation and plastic degradation, even without Pseudomonas PL-01 or Bacillus PL-01 addition. Fourier Transform Infrared (FTIR) analysis complemented the results; there were attenuated peaks with decreasing peaks transmittances. This FTIR peaks indicated chemical functional group changes happened among the plastic compounds after 16 weeks incubation time.

  16. Partners in crime: The role of tandem modules in gene transcription.

    PubMed

    Sharma, Rajal; Zhou, Ming-Ming

    2015-09-01

    Histones and their modifications play an important role in the regulation of gene transcription. Numerous modifications, such as acetylation, phosphorylation, methylation, ubiquitination, and SUMOylation, have been described. These modifications almost always co-occur and thereby increase the combinatorial complexity of post-translational modification detection. The domains that recognize these histone modifications often occur in tandem in the context of larger proteins and complexes. The presence of multiple modifications can positively or negatively regulate the binding of these tandem domains, influencing downstream cellular function. Alternatively, these tandem domains can have novel functions from their independent parts. Here we summarize structural and functional information known about major tandem domains and their histone binding properties. An understanding of these interactions is key for the development of epigenetic therapy. © 2015 The Protein Society.

  17. Air and Surface Sampling Method for Assessing Exposures to Quaternary Ammonium Compounds Using Liquid Chromatography Tandem Mass Spectrometry.

    PubMed

    LeBouf, Ryan F; Virji, Mohammed Abbas; Ranpara, Anand; Stefaniak, Aleksandr B

    2017-07-01

    This method was designed for sampling select quaternary ammonium (quat) compounds in air or on surfaces followed by analysis using ultraperformance liquid chromatography tandem mass spectrometry. Target quats were benzethonium chloride, didecyldimethylammonium bromide, benzyldimethyldodecylammonium chloride, benzyldimethyltetradecylammonium chloride, and benzyldimethylhexadecylammonium chloride. For air sampling, polytetrafluoroethylene (PTFE) filters are recommended for 15-min to 24-hour sampling. For surface sampling, Pro-wipe® 880 (PW) media was chosen. Samples were extracted in 60:40 acetonitrile:0.1% formic acid for 1 hour on an orbital shaker. Method detection limits range from 0.3 to 2 ng/ml depending on media and analyte. Matrix effects of media are minimized through the use of multiple reaction monitoring versus selected ion recording. Upper confidence limits on accuracy meet the National Institute for Occupational Safety and Health 25% criterion for PTFE and PW media for all analytes. Using PTFE and PW analyzed with multiple reaction monitoring, the method quantifies levels among the different quats compounds with high precision (<10% relative standard deviation) and low bias (<11%). The method is sensitive enough with very low method detection limits to capture quats on air sampling filters with only a 15-min sample duration with a maximum assessed storage time of 103 days before sample extraction. This method will support future exposure assessment and quantitative epidemiologic studies to explore exposure-response relationships and establish levels of quats exposures associated with adverse health effects. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  18. Degradation rate of praziquantel and fenbendazole in rainbow trout following oral administration.

    PubMed

    Soukupova-Markova, Zdenka; Doubkova, Veronika; Marsalek, Petr; Svobodova, Zdenka; Papezikova, Ivana; Lang, Stepan; Navratil, Stanislav; Palikova, Miroslava

    2015-01-01

    The aim of this study was to evaluate and compare the rate of degradation and elimination of praziquantel and fenbendazole antiparasitics following oral administration to salmonids. In addition, we determine whether the length of the legal withdrawal period is sufficient for complete elimination of antiparasitic residue from the body. The use of these drugs in fish is currently considered off-label and data on degradation are not available for rainbow trout. The model species for this experiment was the rainbow trout (Oncorhynchus mykiss) and praziquantel and fenbendazole were chosen for experimental therapy. Both drugs were administered into the gastrointestinal tract using a stomach tube. Concentrations of fenbendazole and praziquantel were established through high performance liquid chromatography-tandem mass spectrometry. Our results show that concentrations of praziquantel and fenbendazole reach their maximum in the body within 24 hours of administration, with concentrations dropping sharply over the following 24 hours. With one exception, when trace amounts of both substances were found in blood plasma, the drugs were completely degraded and eliminated from the body by the end of the experiment (corresponding to 497.6 degree days). Praziquantel and fenbendazole both show a high rate of degradation and elimination from fish. As both substances were eliminated from the body within the required withdrawal period (i.e. within 500 degree days) they can be safely used based on current knowledge of their therapeutic effect for treating helminth infections.

  19. Lumen degradation analysis of LED lamps based on the subsystem isolation method.

    PubMed

    Ke, Hong-Liang; Hao, Jian; Tu, Jian-Hui; Miao, Pei-Xian; Wang, Chao-Quan; Cui, Jing-Zhong; Sun, Qiang; Sun, Ren-Tao

    2018-02-01

    The lumen degradation of LED lamps undergoing an accelerated aging test is investigated. The entire LED lamp is divided into three subsystems, namely, driver, lampshade, and LED light source. The parameters of output power [Watts (W)], transmittance (%), and lumen flux (lm) are adopted in the analysis of the degradation of the driver, lampshade, and LED light source, respectively. Two groups of LED lamps are aged under the ambient temperatures of 25°C and 85°C, respectively, with the aging time of 2000 h. The lumen degradation of the lamps is from 3.8% to 4.9% for the group under a temperature of 25°C and from 10.6% to 12.7% for the group under a temperature of 85°C. The LED light source is the most aggressive part of the three subsystems, which accounts for 70.5% of the lumen degradation of the LED lamp on average. The lampshade is the second degradation source, which causes 21.5% of the total amount on average. The driver is the third degradation source, which causes 6.5% under 25°C and 2.8% under 85°C of the total amount on average.

  20. Characterization of crude oil biomarkers using comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry.

    PubMed

    Mogollón, Noroska Gabriela Salazar; Prata, Paloma Santana; Dos Reis, Jadson Zeni; Neto, Eugênio Vaz Dos Santos; Augusto, Fabio

    2016-09-01

    Oil samples from Recôncavo basin (NE Brazil), previously analyzed by traditional techniques such as gas chromatography coupled to tandem mass spectrometry, were evaluated using comprehensive two-dimensional gas chromatography coupled to quadrupole mass spectrometry and comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry along with simplified methods of samples preparation to evaluate the differences and advantages of these analytical techniques to better understand the development of the organic matter in this basin without altering the normal distribution of the compounds in the samples. As a result, the geochemical parameters calculated by comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry described better the origin, maturity, and biodegradation of both samples probably by increased selectivity, resolution, and sensitivity inherent of the multidimensional technique. Additionally, the detection of the compounds such as, the C(14α-) homo-26-nor-17α-hopane series, diamoretanes, nor-spergulanes, C19 -C26 A-nor-steranes and 4α-methylsteranes resolved and detected by comprehensive two-dimensional gas chromatography coupled to tandem mass spectrometry were key to classify and differentiate these lacustrine samples according to their maturity and deposition conditions. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Multi-residue method for the determination of pesticides and pesticide metabolites in honeybees by liquid and gas chromatography coupled with tandem mass spectrometry--Honeybee poisoning incidents.

    PubMed

    Kiljanek, Tomasz; Niewiadowska, Alicja; Semeniuk, Stanisław; Gaweł, Marta; Borzęcka, Milena; Posyniak, Andrzej

    2016-02-26

    A method for the determination of 200 pesticides and pesticide metabolites in honeybee samples has been developed and validated. Almost 98% of compounds included in this method are approved to use within European Union, as active substances of plant protection products or veterinary medicinal products used by beekeepers to control mites Varroa destructor in hives. Many significant metabolites, like metabolites of imidacloprid, thiacloprid, fipronil, methiocarb and amitraz, are also possible to detect. The sample preparation was based on the buffered QuEChERS method. Samples of bees were extracted with acetonitrile containing 1% acetic acid and then subjected to clean-up by dispersive solid phase extraction (dSPE) using a new Z-Sep+ sorbent and PSA. The majority of pesticides, including neonicotionoids and their metabolites, were analyzed by liquid chromatography tandem mass spectrometry (LC-MS/MS) but some of pesticides, especially pyrethroid insecticides, were analyzed by gas chromatography tandem mass spectrometry (GC-MS/MS). The procedure was validated according to the Guidance document SANCO/12571/2013 at four concentration levels: 1, 5, 10 and 100 ng/g bees and verified in the international proficiency test. The analysis of bee samples spiked at the limit of quantification (LOQ) showed about 98% mean recovery value (trueness) and 97% of analytes showed recovery in the required range of 70-120% and RSDr (precision) below 20%. Linearity and matrix effects were also established. The LOQs of pesticides were in the range of 1-100 ng/g. The developed method allows determination of insecticides at concentrations of 10 ng/g or less, except abamectin and tebufenozide. LOQ values are lower than the median lethal doses LD50 for bees. The method was used to investigate more than 70 honeybee poisoning incidents. Data about detected pesticides and their metabolites are included. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Perovskite-perovskite tandem photovoltaics with optimized band gaps

    NASA Astrophysics Data System (ADS)

    Eperon, Giles E.; Leijtens, Tomas; Bush, Kevin A.; Prasanna, Rohit; Green, Thomas; Wang, Jacob Tse-Wei; McMeekin, David P.; Volonakis, George; Milot, Rebecca L.; May, Richard; Palmstrom, Axel; Slotcavage, Daniel J.; Belisle, Rebecca A.; Patel, Jay B.; Parrott, Elizabeth S.; Sutton, Rebecca J.; Ma, Wen; Moghadam, Farhad; Conings, Bert; Babayigit, Aslihan; Boyen, Hans-Gerd; Bent, Stacey; Giustino, Feliciano; Herz, Laura M.; Johnston, Michael B.; McGehee, Michael D.; Snaith, Henry J.

    2016-11-01

    We demonstrate four- and two-terminal perovskite-perovskite tandem solar cells with ideally matched band gaps. We develop an infrared-absorbing 1.2-electron volt band-gap perovskite, FA0.75Cs0.25Sn0.5Pb0.5I3, that can deliver 14.8% efficiency. By combining this material with a wider-band gap FA0.83Cs0.17Pb(I0.5Br0.5)3 material, we achieve monolithic two-terminal tandem efficiencies of 17.0% with >1.65-volt open-circuit voltage. We also make mechanically stacked four-terminal tandem cells and obtain 20.3% efficiency. Notably, we find that our infrared-absorbing perovskite cells exhibit excellent thermal and atmospheric stability, not previously achieved for Sn-based perovskites. This device architecture and materials set will enable “all-perovskite” thin-film solar cells to reach the highest efficiencies in the long term at the lowest costs.

  3. Stacking multiple connecting functional materials in tandem organic light-emitting diodes

    PubMed Central

    Zhang, Tao; Wang, Deng-Ke; Jiang, Nan; Lu, Zheng-Hong

    2017-01-01

    Tandem device is an important architecture in fabricating high performance organic light-emitting diodes and organic photovoltaic cells. The key element in making a high performance tandem device is the connecting materials stack, which plays an important role in electric field distribution, charge generation and charge injection. For a tandem organic light-emitting diode (OLED) with a simple Liq/Al/MoO3 stack, we discovered that there is a significant current lateral spreading causing light emission over an extremely large area outside the OLED pixel when the Al thickness exceeds 2 nm. This spread light emission, caused by an inductive electric field over one of the device unit, limits one’s ability to fabricate high performance tandem devices. To resolve this issue, a new connecting materials stack with a C60 fullerene buffer layer is reported. This new structure permits optimization of the Al metal layer in the connecting stack and thus enables us to fabricate an efficient tandem OLED having a high 155.6 cd/A current efficiency and a low roll-off (or droop) in current efficiency. PMID:28225028

  4. Validation of a method for simultaneous determination of nitroimidazoles, benzimidazoles and chloramphenicols in swine tissues by ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Xia, Xi; Wang, Yuanyuan; Wang, Xia; Li, Yun; Zhong, Feng; Li, Xiaowei; Huang, Yaoling; Ding, Shuangyang; Shen, Jianzhong

    2013-05-31

    This paper presents a sensitive and confirmatory multi-residue method for the analysis of 23 veterinary drugs and metabolites belonging to three classes (nitroimidazoles, benzimidazoles, and chloramphenicols) in porcine muscle, liver, and kidney. After extracted with ethyl acetate and basic ethyl acetate sequentially, the crude extracts were defatted with hexane and further purified using Oasis MCX solid-phase extraction cartridges. Rapid determination was carried out by ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry. Data acquisition was performed under positive and negative mode simultaneously. Recoveries based on matrix-matched calibrations for meat, liver, and kidney ranged from 50.6 to 108.1%. The method quantification limits were in the range of 3-100ng/kg. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Simultaneous determination of four alkaloids in Lindera aggregata by ultra-high-pressure liquid chromatography-tandem mass spectrometry.

    PubMed

    Han, Zheng; Zheng, Yunliang; Chen, Na; Luan, Lianjun; Zhou, Changxin; Gan, Lishe; Wu, Yongjiang

    2008-11-28

    A new separation and quantification method using liquid chromatography under ultra-high-pressure in combination with tandem mass spectrometry (MS/MS) was developed for simultaneous determination of four alkaloids in Lindera aggregata. The analysis was performed on an Acquity UPLC BEH C(18) column (50mmx2.1mm, 1.7microm particle size; Waters, Milford, MA, USA) utilizing a gradient elution profile and a mobile phase consisting of (A) water containing 10mM ammonium acetate adjusted to pH 3 with acetic acid and (B) acetonitrile. An electrospray ionization (ESI)-tandem interface in the positive mode was employed prior to mass spectrometric detection. The calibration curve was linear over the range of 17.1-856ng for boldine, 42.4-2652ng for norboldine, 6.1-304ng for reticuline and 0.5-50ng for linderegatine, respectively. The average recoveries ranged from 99.2 to 101.4% with RSDs< or =2.7%. Then, four L. aggregata samples from different batches were analyzed using the established method. The results indicated that ultra-high-pressure liquid chromatography-tandem mass spectrometry provided improved chromatographic parameters resulting in significantly increased sample throughput including lower solvent consumption and lower limits of quantitation (LOQs) for most of target analytes compared to previous method employing conventional high-performance liquid chromatography (HPLC) separation. So, the established method was validated, sensitive and reliable for the determination of four alkaloids in L. aggregata.

  6. Perovskite Solar Cells for High-Efficiency Tandems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGehee, Michael; Buonassisi, Tonio

    moisture penetration to overcome the often-reported thermal and environmental instability of metal halide perovskites. Previous perovskite-containing tandems utilized molybdenum oxide (MoO x) as a sputter buffer layer, but this has raised concerns over long-term stability, as the iodide in the perovskite can chemically react with MoO x. Mixed-cation perovskite solar cells have consistently outperformed their single-cation counterparts. The first perovskite device to exceed 20% PCE was fabricated with a mixture of methylammonium (MA) and formamidinium (FA). Recent reports have shown promising results with the introduction of cesium mixtures, enabling high efficiencies with improved photo-, moisture, and thermal stability. The increased moisture and thermal stability are especially important as they broaden the parameter space for processing on top of the perovskite, enabling the deposition of metal oxide contacts through atomic layer deposition (ALD) or chemical vapor deposition (CVD) that may require elevated temperatures or water as a counter reagent. Both titanium dioxide (TiO 2) and tin oxide (SnO 2) have consistently proven to be effective electron-selective contacts for perovskite solar cells and both can be deposited via ALD at temperatures below 150 °C. We introduced a bilayer of SnO 2 and zinc tin oxide (ZTO) that can be deposited by either low-temperature ALD or pulsed-CVD as a window layer with minimal parasitic absorption, efficient electron extraction, and sufficient buffer properties to prevent the organic and perovskite layers from damage during the subsequent sputter deposition of a transparent ITO electrode. We explored pulsed-CVD as a modified ALD process with a continual, rather than purely step-wise, growth component in order to considerably reduce the process time of the SnO 2 deposition process and minimize potential perovskite degradation. These layers, when used in an excellent mixed-cation perovskite solar cell atop a silicon solar cell tuned to

  7. Development and validation of a hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the quantification of lipid-related extracellular metabolites in Saccharomyces cerevisiae.

    PubMed

    Sun, Tao; Wetzel, Stephanie J; Johnson, Mitchell E; Surlow, Beth A; Patton-Vogt, Jana

    2012-05-15

    A highly sensitive hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method was developed and validated for the quantification of glycerophosphoinositol (GroPIns), glycerophosphocholine (GroPCho), glycerol 3-phosphate (GroP), inositol, and choline in the extracellular medium of Saccharomyces cerevisiae. The media samples were pretreated with a single two-phase liquid extraction. Chromatographic separation was achieved on a Waters Xbridge HILIC (150 mm × 4.6 mm, 5 μm) column under isocratic conditions using a mobile phase composed of acetonitrile/water, 70:30 (v/v) with 10mM ammonium acetate (pH adjusted to 4.5) at a flow-rate of 0.5 mL/min. Using a triple quadrupole tandem mass spectrometer, samples were detected in multiple reaction monitoring (MRM) mode via an electrospray ionization (ESI) source. The calibration curves were linear (r² ≥ 0.995) over the range of 0.5-150 nM, with the lower limit of quantitation validated at 0.5 nM for all analytes. The intra- and inter-day precision (calculated by coefficient of variation, CV%) ranged from 1.24 to 5.88% and 2.46 to 9.77%, respectively, and intra- and inter-day accuracy (calculated by relative error, RE%) was between -8.42 to 8.22% and -9.35 to 6.62%, respectively, at all quality control levels. The extracellular metabolites were stable throughout various storage stability studies. The fully validated method was successfully applied to determine the extracellular levels of phospholipid-related metabolites in S. cerevisiae. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. TandEM: Titan and Enceladus mission

    USGS Publications Warehouse

    Coustenis, A.; Atreya, S.K.; Balint, T.; Brown, R.H.; Dougherty, M.K.; Ferri, F.; Fulchignoni, M.; Gautier, D.; Gowen, R.A.; Griffith, C.A.; Gurvits, L.I.; Jaumann, R.; Langevin, Y.; Leese, M.R.; Lunine, J.I.; McKay, C.P.; Moussas, X.; Muller-Wodarg, I.; Neubauer, F.; Owen, T.C.; Raulin, F.; Sittler, E.C.; Sohl, F.; Sotin, Christophe; Tobie, G.; Tokano, T.; Turtle, E.P.; Wahlund, J.-E.; Waite, J.H.; Baines, K.H.; Blamont, J.; Coates, A.J.; Dandouras, I.; Krimigis, T.; Lellouch, E.; Lorenz, R.D.; Morse, A.; Porco, C.C.; Hirtzig, M.; Saur, J.; Spilker, T.; Zarnecki, J.C.; Choi, E.; Achilleos, N.; Amils, R.; Annan, P.; Atkinson, D.H.; Benilan, Y.; Bertucci, C.; Bezard, B.; Bjoraker, G.L.; Blanc, M.; Boireau, L.; Bouman, J.; Cabane, M.; Capria, M.T.; Chassefiere, E.; Coll, P.; Combes, M.; Cooper, J.F.; Coradini, A.; Crary, F.; Cravens, T.; Daglis, I.A.; de Angelis, E.; De Bergh, C.; de Pater, I.; Dunford, C.; Durry, G.; Dutuit, O.; Fairbrother, D.; Flasar, F.M.; Fortes, A.D.; Frampton, R.; Fujimoto, M.; Galand, M.; Grasset, O.; Grott, M.; Haltigin, T.; Herique, A.; Hersant, F.; Hussmann, H.; Ip, W.; Johnson, R.; Kallio, E.; Kempf, S.; Knapmeyer, M.; Kofman, W.; Koop, R.; Kostiuk, T.; Krupp, N.; Kuppers, M.; Lammer, H.; Lara, L.-M.; Lavvas, P.; Le, Mouelic S.; Lebonnois, S.; Ledvina, S.; Li, Ji; Livengood, T.A.; Lopes, R.M.; Lopez-Moreno, J. -J.; Luz, D.; Mahaffy, P.R.; Mall, U.; Martinez-Frias, J.; Marty, B.; McCord, T.; Salvan, C.M.; Milillo, A.; Mitchell, D.G.; Modolo, R.; Mousis, O.; Nakamura, M.; Neish, Catherine D.; Nixon, C.A.; Mvondo, D.N.; Orton, G.; Paetzold, M.; Pitman, J.; Pogrebenko, S.; Pollard, W.; Prieto-Ballesteros, O.; Rannou, P.; Reh, K.; Richter, L.; Robb, F.T.; Rodrigo, R.; Rodriguez, S.; Romani, P.; Bermejo, M.R.; Sarris, E.T.; Schenk, P.; Schmitt, B.; Schmitz, N.; Schulze-Makuch, D.; Schwingenschuh, K.; Selig, A.; Sicardy, B.; Soderblom, L.; Spilker, L.J.; Stam, D.; Steele, A.; Stephan, K.; Strobel, D.F.; Szego, K.; Szopa,

    2009-01-01

    TandEM was proposed as an L-class (large) mission in response to ESA’s Cosmic Vision 2015–2025 Call, and accepted for further studies, with the goal of exploring Titan and Enceladus. The mission concept is to perform in situ investigations of two worlds tied together by location and properties, whose remarkable natures have been partly revealed by the ongoing Cassini–Huygens mission. These bodies still hold mysteries requiring a complete exploration using a variety of vehicles and instruments. TandEM is an ambitious mission because its targets are two of the most exciting and challenging bodies in the Solar System. It is designed to build on but exceed the scientific and technological accomplishments of the Cassini–Huygens mission, exploring Titan and Enceladus in ways that are not currently possible (full close-up and in situ coverage over long periods of time). In the current mission architecture, TandEM proposes to deliver two medium-sized spacecraft to the Saturnian system. One spacecraft would be an orbiter with a large host of instruments which would perform several Enceladus flybys and deliver penetrators to its surface before going into a dedicated orbit around Titan alone, while the other spacecraft would carry the Titan in situ investigation components, i.e. a hot-air balloon (Montgolfière) and possibly several landing probes to be delivered through the atmosphere.

  9. TandEM: Titan and Enceladus mission

    NASA Astrophysics Data System (ADS)

    Coustenis, A.; Atreya, S. K.; Balint, T.; Brown, R. H.; Dougherty, M. K.; Ferri, F.; Fulchignoni, M.; Gautier, D.; Gowen, R. A.; Griffith, C. A.; Gurvits, L. I.; Jaumann, R.; Langevin, Y.; Leese, M. R.; Lunine, J. I.; McKay, C. P.; Moussas, X.; Müller-Wodarg, I.; Neubauer, F.; Owen, T. C.; Raulin, F.; Sittler, E. C.; Sohl, F.; Sotin, C.; Tobie, G.; Tokano, T.; Turtle, E. P.; Wahlund, J.-E.; Waite, J. H.; Baines, K. H.; Blamont, J.; Coates, A. J.; Dandouras, I.; Krimigis, T.; Lellouch, E.; Lorenz, R. D.; Morse, A.; Porco, C. C.; Hirtzig, M.; Saur, J.; Spilker, T.; Zarnecki, J. C.; Choi, E.; Achilleos, N.; Amils, R.; Annan, P.; Atkinson, D. H.; Bénilan, Y.; Bertucci, C.; Bézard, B.; Bjoraker, G. L.; Blanc, M.; Boireau, L.; Bouman, J.; Cabane, M.; Capria, M. T.; Chassefière, E.; Coll, P.; Combes, M.; Cooper, J. F.; Coradini, A.; Crary, F.; Cravens, T.; Daglis, I. A.; de Angelis, E.; de Bergh, C.; de Pater, I.; Dunford, C.; Durry, G.; Dutuit, O.; Fairbrother, D.; Flasar, F. M.; Fortes, A. D.; Frampton, R.; Fujimoto, M.; Galand, M.; Grasset, O.; Grott, M.; Haltigin, T.; Herique, A.; Hersant, F.; Hussmann, H.; Ip, W.; Johnson, R.; Kallio, E.; Kempf, S.; Knapmeyer, M.; Kofman, W.; Koop, R.; Kostiuk, T.; Krupp, N.; Küppers, M.; Lammer, H.; Lara, L.-M.; Lavvas, P.; Le Mouélic, S.; Lebonnois, S.; Ledvina, S.; Li, J.; Livengood, T. A.; Lopes, R. M.; Lopez-Moreno, J.-J.; Luz, D.; Mahaffy, P. R.; Mall, U.; Martinez-Frias, J.; Marty, B.; McCord, T.; Menor Salvan, C.; Milillo, A.; Mitchell, D. G.; Modolo, R.; Mousis, O.; Nakamura, M.; Neish, C. D.; Nixon, C. A.; Nna Mvondo, D.; Orton, G.; Paetzold, M.; Pitman, J.; Pogrebenko, S.; Pollard, W.; Prieto-Ballesteros, O.; Rannou, P.; Reh, K.; Richter, L.; Robb, F. T.; Rodrigo, R.; Rodriguez, S.; Romani, P.; Ruiz Bermejo, M.; Sarris, E. T.; Schenk, P.; Schmitt, B.; Schmitz, N.; Schulze-Makuch, D.; Schwingenschuh, K.; Selig, A.; Sicardy, B.; Soderblom, L.; Spilker, L. J.; Stam, D.; Steele, A.; Stephan, K.; Strobel, D. F.; Szego, K.; Szopa, C.; Thissen, R.; Tomasko, M. G.; Toublanc, D.; Vali, H.; Vardavas, I.; Vuitton, V.; West, R. A.; Yelle, R.; Young, E. F.

    2009-03-01

    TandEM was proposed as an L-class (large) mission in response to ESA’s Cosmic Vision 2015-2025 Call, and accepted for further studies, with the goal of exploring Titan and Enceladus. The mission concept is to perform in situ investigations of two worlds tied together by location and properties, whose remarkable natures have been partly revealed by the ongoing Cassini-Huygens mission. These bodies still hold mysteries requiring a complete exploration using a variety of vehicles and instruments. TandEM is an ambitious mission because its targets are two of the most exciting and challenging bodies in the Solar System. It is designed to build on but exceed the scientific and technological accomplishments of the Cassini-Huygens mission, exploring Titan and Enceladus in ways that are not currently possible (full close-up and in situ coverage over long periods of time). In the current mission architecture, TandEM proposes to deliver two medium-sized spacecraft to the Saturnian system. One spacecraft would be an orbiter with a large host of instruments which would perform several Enceladus flybys and deliver penetrators to its surface before going into a dedicated orbit around Titan alone, while the other spacecraft would carry the Titan in situ investigation components, i.e. a hot-air balloon (Montgolfière) and possibly several landing probes to be delivered through the atmosphere.

  10. Validated Method for the Quantification of Baclofen in Human Plasma Using Solid-Phase Extraction and Liquid Chromatography–Tandem Mass Spectrometry

    PubMed Central

    Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue

    2016-01-01

    Abstract A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography–tandem mass spectrometry (LC–MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r2 > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. PMID:26538544

  11. Hog Charm II tetracycline test screening results compared with a liquid chromatography tandem mass spectrometry 10-μg/kg method.

    PubMed

    Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce

    2012-02-01

    Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.

  12. A rapid liquid chromatography tandem mass spectrometry-based method for measuring propranolol on dried blood spots.

    PubMed

    Della Bona, Maria Luisa; Malvagia, Sabrina; Villanelli, Fabio; Giocaliere, Elisa; Ombrone, Daniela; Funghini, Silvia; Filippi, Luca; Cavallaro, Giacomo; Bagnoli, Paola; Guerrini, Renzo; la Marca, Giancarlo

    2013-05-05

    Propranolol, a non-selective beta blocker drug, is used in young infants and newborns for treating several heart diseases; its pharmacokinetics has been extensively evaluated in adult patients using extrapolation to treat pediatric population. The purpose of the present study was to develop and validate a method to measure propranolol levels in dried blood spots. The analysis was performed by using liquid chromatography/tandem mass spectrometry operating in multiple reaction monitoring mode. The calibration curve in matrix was linear in the concentration range of 2.5-200 μg/L with correlation coefficient r=0.9996. Intra-day and inter-day precisions and biases were less than 8.0% (n=10) and 11.5% (n=10) respectively. The recoveries ranged from 94 to 100% and the matrix effect did not result in a severe signal suppression. Propranolol on dried blood spot showed a good stability at three different temperatures for one month. This paper describes a micromethod for measuring propranolol levels on dried blood spot, which determines a great advantage in neonates or young infants during pharmacokinetic studies because of less invasive sampling and small blood volume required. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Efficient semitransparent perovskite solar cells for 23.0%-efficiency perovskite/silicon four-terminal tandem cells

    DOE PAGES

    Chen, Bo; Bai, Yang; Yu, Zhengshan; ...

    2016-07-19

    Here, we have investigated semi-transparent perovskite solar cells and infrared enhanced silicon heterojunction cells for high-efficiency tandem devices. A semi-transparent metal electrode with good electrical conductivity and optical transparency has been fabricated by thermal evaporation of 7 nm of Au onto a 1-nm-thick Cu seed layer. For this electrode to reach its full potential, MAPbI3 thin films were formed by a modified one-step spin-coating method, resulting in a smooth layer that allowed the subsequent metal thin film to remain continuous. The fabricated semi-transparent perovskite solar cells demonstrated 16.5% efficiency under one-sun illumination, and were coupled with infrared-enhanced silicon heterojunction cellsmore » tuned specifically for perovskite/Si tandem devices. A double-layer antireflection coating at the front side and MgF2 reflector at rear side of the silicon heterojunction cells reduced parasitic absorption of near-infrared light, leading to 6.5% efficiency after filtering with a perovskite device and 23.0% summed efficiency for the perovskite/Si tandem device.« less

  14. Efficient semitransparent perovskite solar cells for 23.0%-efficiency perovskite/silicon four-terminal tandem cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Bo; Bai, Yang; Yu, Zhengshan

    Here, we have investigated semi-transparent perovskite solar cells and infrared enhanced silicon heterojunction cells for high-efficiency tandem devices. A semi-transparent metal electrode with good electrical conductivity and optical transparency has been fabricated by thermal evaporation of 7 nm of Au onto a 1-nm-thick Cu seed layer. For this electrode to reach its full potential, MAPbI3 thin films were formed by a modified one-step spin-coating method, resulting in a smooth layer that allowed the subsequent metal thin film to remain continuous. The fabricated semi-transparent perovskite solar cells demonstrated 16.5% efficiency under one-sun illumination, and were coupled with infrared-enhanced silicon heterojunction cellsmore » tuned specifically for perovskite/Si tandem devices. A double-layer antireflection coating at the front side and MgF2 reflector at rear side of the silicon heterojunction cells reduced parasitic absorption of near-infrared light, leading to 6.5% efficiency after filtering with a perovskite device and 23.0% summed efficiency for the perovskite/Si tandem device.« less

  15. Stable isotope labeling tandem mass spectrometry (SILT) to quantify protein production and clearance rates

    PubMed Central

    Bateman, Randall J.; Munsell, Ling Y.; Chen, Xianghong; Holtzman, David M.; Yarasheski, Kevin E.

    2007-01-01

    In all biological systems, protein amount is a function of the rate of production and clearance. The speed of a response to a disturbance in protein homeostasis is determined by turnover rate. Quantifying alterations in protein synthesis and clearance rates is vital to understanding disease pathogenesis (e.g., aging, inflammation). No methods exist for quantifying production and clearance rates of low abundance (femtomole) proteins in vivo. We describe a novel, mass spectrometry-based method for quantitating low abundance protein synthesis and clearance rates in vitro and in vivo in animals and humans. The utility of this method is demonstrated with amyloid-beta (Aß), an important low abundance protein involved in Alzheimer's disease pathogenesis. We used in vivo stable isotope labeling, immunoprecipitation of Aß from cerebrospinal fluid, and quantitative liquid chromatography electrospray-ionization tandem mass spectrometry (LC-ESI-tandem MS) to quantify human Aß protein production and clearance rates. The method is sensitive and specific for stable isotope labeled amino acid incorporation into CNS (± 1% accuracy). This in vivo method can be used to identify pathophysiologic changes in protein metabolism; and may serve as a biomarker for monitoring disease risk, progression, or response to novel therapeutic agents. The technique is adaptable to other macromolecules, such as carbohydrates or lipids. PMID:17383190

  16. A novel liquid chromatography-tandem mass spectrometry method for determination of menadione in human plasma after derivatization with 3-mercaptopropionic acid.

    PubMed

    Liu, Ruijuan; Wang, Mengmeng; Ding, Li

    2014-10-01

    Menadione (VK3), an essential fat-soluble naphthoquinone, takes very important physiological and pathological roles, but its detection and quantification is challenging. Herein, a new method was developed for quantification of VK3 in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after derivatization with 3-mercaptopropionic acid via Michael addition reaction. The derivative had been identified by the mass spectra and the derivatization conditions were optimized by considering different parameters. The method was demonstrated with high sensitivity and a low limit of quantification of 0.03 ng mL(-1) for VK3, which is about 33-fold better than that for the direct analysis of the underivatized compound. The method also had good precision and reproducibility. It was applied in the determination of basal VK3 in human plasma and a clinical pharmacokinetic study of menadiol sodium diphosphate. Furthermore, the method for the quantification of VK3 using LC-MS/MS was reported in this paper for the first time, and it will provide an important strategy for the further research on VK3 and menadione analogs. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Development of a fast liquid chromatography-tandem mass spectrometry method for the determination of endocrine-disrupting compounds in waters.

    PubMed

    Di Carro, Marina; Scapolla, Carlo; Liscio, Camilla; Magi, Emanuele

    2010-09-01

    A fast liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS) method was developed to study five endocrine-disrupting compounds (4-n-nonylphenol, bisphenol A, estrone, 17β-estradiol and 17α-ethinylestradiol) in water. Different columns were tested; the chromatographic separation of the analytes was optimized on a Pinnacle DB biphenylic column with a water-acetonitrile gradient elution, which allowed the separation of the selected endocrine-disrupting compounds (EDCs) in less than 6 min. Quantitative analysis was performed in selected reaction monitoring (SRM) mode; two transitions were chosen for each compound, using the most abundant for quantitation. Calibration curves using bisphenol A-d (16) as internal standard were drawn, showing good correlation coefficients (0.9993-0.9998). All figures of merit of the method were satisfactory; limits of detection were in the low pg range for all analytes. The method was then applied to the determination of the analytes in real water samples: to this aim, polar organic chemical integrative samplers (POCIS) were deployed in the influent and in the effluent of a drinking water treatment plant in Liguria (Italy). The EDC level was rather low in the influent and negligible in the outlet, reflecting the expected function of the treatment plant.

  18. A liquid chromatography tandem mass spectrometry method for the simultaneous quantification of 20 drugs of abuse and metabolites in human meconium

    PubMed Central

    Gray, Teresa R.; Shakleya, Diaa M.

    2011-01-01

    A method for the simultaneous quantification of 20 cocaine, amphetamine, opiate, and nicotine analytes in meconium, the first neonatal feces, by liquid chromatography tandem mass spectrometry was developed and validated. Specimen preparation included methanol homogenization and solid phase extraction. Two injections were required to achieve sufficient sensitivity and linear dynamic range. Linearity ranged from 0.5–25 up to 500 ng/g (250 ng/g p-hydroxymethamphetamine), and correlation coefficients were >0.996. Imprecision was <10.0% CV, analytical recovery 85.5–123.1%, and extraction efficiencies >46.7% at three concentrations across the linear range. Despite significant matrix effects of −305.7–40.7%, effects were similar for native and deuterated analytes. No carryover, endogenous or exogenous interferences were observed, with analyte stability at room temperature, 4 °C, and −20 °C and on the autosampler >70%, except for 6-acetylmorphine, hydrocodone, oxycodone, and morphine. Method applicability was demonstrated by analyzing meconium from drug-exposed neonates. PMID:19241063

  19. A strategy of gene overexpression based on tandem repetitive promoters in Escherichia coli.

    PubMed

    Li, Mingji; Wang, Junshu; Geng, Yanping; Li, Yikui; Wang, Qian; Liang, Quanfeng; Qi, Qingsheng

    2012-02-06

    For metabolic engineering, many rate-limiting steps may exist in the pathways of accumulating the target metabolites. Increasing copy number of the desired genes in these pathways is a general method to solve the problem, for example, the employment of the multi-copy plasmid-based expression system. However, this method may bring genetic instability, structural instability and metabolic burden to the host, while integrating of the desired gene into the chromosome may cause inadequate transcription or expression. In this study, we developed a strategy for obtaining gene overexpression by engineering promoter clusters consisted of multiple core-tac-promoters (MCPtacs) in tandem. Through a uniquely designed in vitro assembling process, a series of promoter clusters were constructed. The transcription strength of these promoter clusters showed a stepwise enhancement with the increase of tandem repeats number until it reached the critical value of five. Application of the MCPtacs promoter clusters in polyhydroxybutyrate (PHB) production proved that it was efficient. Integration of the phaCAB genes with the 5CPtacs promoter cluster resulted in an engineered E.coli that can accumulate 23.7% PHB of the cell dry weight in batch cultivation. The transcription strength of the MCPtacs promoter cluster can be greatly improved by increasing the tandem repeats number of the core-tac-promoter. By integrating the desired gene together with the MCPtacs promoter cluster into the chromosome of E. coli, we can achieve high and stale overexpression with only a small size. This strategy has an application potential in many fields and can be extended to other bacteria.

  20. Development of a Tandem Repeat-Based Polymerase Chain Displacement Reaction Method for Highly Sensitive Detection of 'Candidatus Liberibacter asiaticus'.

    PubMed

    Lou, Binghai; Song, Yaqin; RoyChowdhury, Moytri; Deng, Chongling; Niu, Ying; Fan, Qijun; Tang, Yan; Zhou, Changyong

    2018-02-01

    Huanglongbing (HLB) is one of the most destructive diseases in citrus production worldwide. Early detection of HLB pathogens can facilitate timely removal of infected citrus trees in the field. However, low titer and uneven distribution of HLB pathogens in host plants make reliable detection challenging. Therefore, the development of effective detection methods with high sensitivity is imperative. This study reports the development of a novel method, tandem repeat-based polymerase chain displacement reaction (TR-PCDR), for the detection of 'Candidatus Liberibacter asiaticus', a widely distributed HLB-associated bacterium. A uniquely designed primer set (TR2-PCDR-F/TR2-PCDR-1R) and a thermostable Taq DNA polymerase mutant with strand displacement activity were used for TR-PCDR amplification. Performed in a regular thermal cycler, TR-PCDR could produce more than two amplicons after each amplification cycle. Sensitivity of the developed TR-PCDR was 10 copies of target DNA fragment. The sensitive level was proven to be 100× higher than conventional PCR and similar to real-time PCR. Data from the detection of 'Ca. L. asiaticus' with filed samples using the above three methods also showed similar results. No false-positive TR-PCDR amplification was observed from healthy citrus samples and water controls. These results thereby illustrated that the developed TR-PCDR method can be applied to the reliable, highly sensitive, and cost-effective detection of 'Ca. L. asiaticus'.

  1. A practical method for measuring the ion exchange capacity decrease of hydroxide exchange membranes during intrinsic degradation

    NASA Astrophysics Data System (ADS)

    Kreuer, Klaus-Dieter; Jannasch, Patric

    2018-01-01

    In this work we present a practical thermogravimetric method for quantifying the IEC (ion exchange capacity) decrease of hydroxide exchange membranes (HEMs) during intrinsic degradation mainly occurring through nucleophilic attack of the anion exchanging group by hydroxide ions. The method involves measuring weight changes under controlled temperature and relative humidity. These conditions are close to these in a fuel cell, i.e. the measured degradation rate includes all effects originating from the polymeric structure, the consumption of hydroxide ions and the release of water. In particular, this approach involves no added solvents or base, thereby avoiding inaccuracies that may arise in other methods due to the presence of solvents (other than water) or co-ions (such as Na+ or K+). We demonstrate the method by characterizing the decomposition of membranes consisting of poly(2,6-dimethyl-1,4-phenylene oxide) functionalized with trimethyl-pentyl-ammonium side chains. The decomposition rate is found to depend on temperature, relative humidity RH (controlling the hydration number λ) and the total water content (controlled by the actual IEC and RH).

  2. Effect of preparation methods on the activity of titanium dioxide-carbon nitride composites for photocatalytic degradation of salicylic acid

    NASA Astrophysics Data System (ADS)

    Yuliati, L.; Salleh, A. M.; Hatta, M. H. M.; Lintang, H. O.

    2018-04-01

    In this study, titanium dioxide-carbon nitride (TiO2-CN) composites were prepared by three methods, which were one pot oxidation, impregnation, and physical mixing. Each series of the photocatalysts was prepared with different ratios of titanium to carbon (Ti/C), i.e., 1, 5, 10, 20, and 50 mol%. All samples were characterized by X-ray diffraction (XRD) and diffuse reflectance ultraviolet-visible (DR UV-Vis) spectroscopies. The characterization results confirmed the successful preparation of TiO2, CN, and the TiO2-CN composites. Photocatalytic activity tests were carried out for degradation of salicylic acid at room temperature for 6 h under UV and visible light irradiations. It was confirmed that all the prepared TiO2-CN composites showed better photocatalytic activities than the bare TiO2 and the bare CN. Under UV light irradiation, 90.6% of salicylic acid degradation was achieved on the best composite prepared by one pot oxidation with 5 mol% of titanium to carbon (Ti/C) ratio. On the other hand, the highest degradation under visible light irradiation was 94.3%, observed on the composite that was prepared also by one pot oxidation method with the Ti/C ratio of 10 mol%. Therefore, among the investigated methods, the best method to prepare the titanium dioxide-carbon nitride composites with high photocatalytic activity was one pot oxidation method.

  3. Tandem microwave waste remediation and decontamination system

    DOEpatents

    Wicks, George G.; Clark, David E.; Schulz, Rebecca L.

    1999-01-01

    The invention discloses a tandem microwave system consisting of a primary chamber in which microwave energy is used for the controlled combustion of materials. A second chamber is used to further treat the off-gases from the primary chamber by passage through a susceptor matrix subjected to additional microwave energy. The direct microwave radiation and elevated temperatures provide for significant reductions in the qualitative and quantitative emissions of the treated off gases. The tandem microwave system can be utilized for disinfecting wastes, sterilizing materials, and/or modifying the form of wastes to solidify organic or inorganic materials. The simple design allows on-site treatment of waste by small volume waste generators.

  4. Optimizing a tandem disk model

    NASA Astrophysics Data System (ADS)

    Healey, J. V.

    1983-08-01

    The optimum values of the solidity ratio, tip speed ratio (TSR), and the preset angle of attack, the corresponding distribution, and the breakdown mechanism for a tandem disk model for a crosswind machine such as a Darrieus are examined analytically. Equations are formulated for thin blades with zero drag in consideration of two plane rectangular disks, both perpendicular to the wind flow. Power coefficients are obtained for both disks and comparisons are made between a single-disk system and a two-disk system. The power coefficient for the tandem disk model is shown to be a sum of the coefficients of the individual disks, with a maximum value of twice the Betz limit at an angle of attack of -1 deg and the TSR between 4-7. The model, applied to the NACA 0012 profile, gives a maximum power coefficient of 0.967 with a solidity ratio of 0.275 and highly limited ranges for the angle of attack and TSR.

  5. The Fundamental Flaws of Immunoassays and Potential Solutions Using Tandem Mass Spectrometry

    PubMed Central

    Hoofnagle, Andrew N.; Wener, Mark H.

    2009-01-01

    Immunoassays have made it possible to measure dozens of individual proteins and other analytes in human samples for help in establishing the diagnosis and prognosis of disease. In too many cases the results of those measurements are misleading and can lead to unnecessary treatment or missed opportunities for therapeutic interventions. These cases stem from problems inherent to immunoassays performed with human samples, which include a lack of concordance across platforms, autoantibodies, anti-reagent antibodies, and the high-dose hook effect. Tandem mass spectrometry may represent a detection method capable of alleviating many of the flaws inherent to immunoassays. We review our understanding of the problems associated with immunoassays on human specimens and describe methodologies using tandem mass spectrometry that could solve some of those problems. We also provide a critical discussion of the potential pitfalls of novel mass spectrometric approaches in the clinical laboratory. PMID:19538965

  6. Scenarios and methods that induce protruding or released CNTs after degradation of nanocomposite materials.

    PubMed

    Hirth, Sabine; Cena, Lorenzo; Cox, Gerhard; Tomović, Zeljko; Peters, Thomas; Wohlleben, Wendel

    2013-04-01

    Nanocomposite materials may be considered as a low-risk application of nanotechnology, if the nanofillers remain embedded throughout the life-cycle of the products in which they are embedded. We hypothesize that release of free CNTs occurs by a combination of mechanical stress and chemical degradation of the polymer matrix. We experimentally address limiting cases: Mechanically released fragments may show tubular protrusions on their surface. Here we identify these protrusions unambiguously as naked CNTs by chemically resolved microscopy and a suitable preparation protocol. By size-selective quantification of fragments we establish as a lower limit that at least 95 % of the CNTs remain embedded. Contrary to classical fiber composite approaches, we link this phenomenon to matrix materials with only a few percent elongation at break, predicting which materials should still cover their CNT nanofillers after machining. Protruding networks of CNTs remain after photochemical degradation of the matrix, and we show that it takes the worst case combinations of weathering plus high-shear wear to release free CNTs in the order of mg/m 2 /year. Synergy of chemical degradation and mechanical energy input is identified as the priority scenario of CNT release, but its lab simulation by combined methods is still far from real-world validation.

  7. Dynamics of tandem bubble interaction in a microfluidic channel

    PubMed Central

    Yuan, Fang; Sankin, Georgy; Zhong, Pei

    2011-01-01

    The dynamics of tandem bubble interaction in a microfluidic channel (800 × 21 μm, W × H) have been investigated using high-speed photography, with resultant fluid motion characterized by particle imaging velocimetry. A single or tandem bubble is produced reliably via laser absorption by micron-sized gold dots (6 μm in diameter with 40 μm in separation distance) coated on a glass surface of the microfluidic channel. Using two pulsed Nd:YAG lasers at λ = 1064 nm and ∼10 μJ/pulse, the dynamics of tandem bubble interaction (individual maximum bubble diameter of 50 μm with a corresponding collapse time of 5.7 μs) are examined at different phase delays. In close proximity (i.e., interbubble distance = 40 μm or γ = 0.8), the tandem bubbles interact strongly with each other, leading to asymmetric deformation of the bubble walls and jet formation, as well as the production of two pairs of vortices in the surrounding fluid rotating in opposite directions. The direction and speed of the jet (up to 95 m/s), as well as the orientation and strength of the vortices can be varied by adjusting the phase delay. PMID:22088007

  8. Dynamics of tandem bubble interaction in a microfluidic channel.

    PubMed

    Yuan, Fang; Sankin, Georgy; Zhong, Pei

    2011-11-01

    The dynamics of tandem bubble interaction in a microfluidic channel (800  ×  21 μm, W × H) have been investigated using high-speed photography, with resultant fluid motion characterized by particle imaging velocimetry. A single or tandem bubble is produced reliably via laser absorption by micron-sized gold dots (6 μm in diameter with 40 μm in separation distance) coated on a glass surface of the microfluidic channel. Using two pulsed Nd:YAG lasers at λ = 1064 nm and ∼10 μJ/pulse, the dynamics of tandem bubble interaction (individual maximum bubble diameter of 50 μm with a corresponding collapse time of 5.7 μs) are examined at different phase delays. In close proximity (i.e., interbubble distance = 40 μm or γ = 0.8), the tandem bubbles interact strongly with each other, leading to asymmetric deformation of the bubble walls and jet formation, as well as the production of two pairs of vortices in the surrounding fluid rotating in opposite directions. The direction and speed of the jet (up to 95 m/s), as well as the orientation and strength of the vortices can be varied by adjusting the phase delay.

  9. Kinetic study and mechanism of Niclosamide degradation.

    PubMed

    Zaazaa, Hala E; Abdelrahman, Maha M; Ali, Nouruddin W; Magdy, Maimana A; Abdelkawy, M

    2014-11-11

    A spectrophotometric kinetic study of Niclosamide alkaline degradation as a function of drug concentration, alkaline concentration and temperature has been established utilizing double divisor-ratio spectra spectrophotometric method. The developed method allowed determination of Niclosamide in presence of its alkaline degradation products; namely; 2-chloro-4-nitro aniline (DEG I) and 5-chloro salicylic acid (DEG II) with characterization of its degradation mechanism. It was found that degradation kinetic of Niclosamide followed pseudo-first order under the established experimental conditions with a degradation rate constant (k) of 0.0829 mol/h and half life (t1/2) of 8.35 h. The overall degradation rate constant as a function of the temperature under the given conditions obeyed Arrhenius equation where the activation energy was calculated to be 3.41 kcal/mol. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. On the Relativistic Correction of Particles Trajectory in Tandem Type Electrostatic Accelerator

    NASA Astrophysics Data System (ADS)

    Minárik, Stanislav

    2015-08-01

    A constant potential is applied to the acceleration of the ion-beam in the tandem type electrostatic accelerator. However, not just one voltage is applied, but instead a number of applications can be made in succession by means of the tandem arrangement of high voltage tubes. This number of voltage applications, which is the number of so-called "stages" of a tandem accelerator, may be two, three, or four, depending on the chosen design. Electrostatic field with approximately constant intensity acts on ions in any stage. In general, non-relativistic dynamics is used for the description of the ion transport in tandem accelerator. Energies of accelerated ions are too low and relativistic effects cannot be commonly observed by standard experimental technique. Estimation of possible relativistic correction of ion trajectories is therefore only a matter of calculation. In this note, we briefly present such calculation. Our aim is to show how using the relativistic dynamics modifies the particles trajectory in tandem type accelerator and what parameters determine this modification.

  11. Simulation of two dimensional electrophoresis and tandem mass spectrometry for teaching proteomics.

    PubMed

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul

    2012-01-01

    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations-2D electrophoresis and tandem mass spectrometry. The two simulations are integrated together and are designed to teach the concept of proteome analysis of prokaryotic and eukaryotic organisms. 2DE-Tandem MS can be used as a freestanding simulation, or in conjunction with a wet lab, to introduce proteomics in the undergraduate classroom. 2DE Tandem MS is a free program available on Sourceforge at https://sourceforge.net/projects/jbf/. It was developed using Java Swing and functions in Mac OSX, Windows, and Linux, ensuring that every student sees a consistent and informative graphical user interface no matter the computer platform they choose. Java must be installed on the host computer to run 2DE Tandem MS. Example classroom exercises are provided in the Supporting Information. Copyright © 2012 Wiley Periodicals, Inc.

  12. InP tunnel junction for InGaAs/InP tandem solar cells

    NASA Technical Reports Server (NTRS)

    Vilela, M. F.; Freundlich, A.; Bensaoula, A.; Medelci, N.; Renaud, P.

    1995-01-01

    Chemical beam epitaxy (CBE) has been shown to allow the growth of high quality materials with reproducible complex compositional and doping profiles. The main advantage of CBE compared to metalorganic chemical vapor deposition (MOCVD), the most popular technique for InP-based photovoltaic device fabrication, is the ability to grow high purity epilayers at much lower temperatures (450-530 C). We have previously shown that CBE is perfectly suited toward the fabrication of complex photovoltaic devices such as InP/InGaAs monolithically integrated tandem solar cells, because its low process temperature preserves the electrical characteristics of the InGaAs tunnel junction commonly used as an ohmic interconnect. In this work using CBE for the fabrication of optically transparent (with respect to the bottom cell) InP tunnel diodes is demonstrated. Epitaxial growth were performed in a Riber CBE 32 system using PH3 and TMIn as III and V precursors. Solid Be (p-type) and Si (n-type) have been used as doping sources, allowing doping levels up to 2 x 10(exp -19)/cu cm and 1 x 10(exp -19)/cu cm for n and p type respectively. The InP tunnel junction characteristics and the influence of the growth's conditions (temperature, growth rate) over its performance have been carefully investigated. InP p(++)/n(++) tunnel junction with peak current densities up to 1600 A/sq cm and maximum specific resistivities (V(sub p)/I(sub p) - peak voltage to peak current ratio) in the range of 10(exp -4) Omega-sq cm were obtained. The obtained peak current densities exceed the highest results previously reported for their lattice matched counterparts, In(0.53)Ga( 0.47)As and should allow the realization of improved minimal absorption losses in the interconnect InP/InGaAs tandem devices for Space applications. Owing to the low process temperature required for the top cell, these devices exhibit almost no degradation of its characteristics after the growth of subsequent thick InP layer suggesting

  13. Development, validation and application of an ultra high performance liquid chromatographic-tandem mass spectrometric method for the simultaneous detection and quantification of five different classes of veterinary antibiotics in swine manure.

    PubMed

    Van den Meersche, Tina; Van Pamel, Els; Van Poucke, Christof; Herman, Lieve; Heyndrickx, Marc; Rasschaert, Geertrui; Daeseleire, Els

    2016-01-15

    In this study, a fast, simple and selective ultra high performance liquid chromatographic-tandem mass spectrometric (UHPLC-MS/MS) method for the simultaneous detection and quantification of colistin, sulfadiazine, trimethoprim, doxycycline, oxytetracycline and ceftiofur and for the detection of tylosin A in swine manure was developed and validated. First, a simple extraction procedure with acetonitrile and 6% trichloroacetic acid was carried out. Second, the supernatant was evaporated and the pellet was reconstituted in 1 ml of water/acetonitrile (80/20) and 0.1% formic acid. Extracts were filtered and analyzed by UHPLC-MS/MS on a Kinetex C18 column using gradient elution. The method developed was validated according to the criteria of Commission Decision 2002/657/EC. Recovery percentages varied between 94% and 106%, repeatability percentages were within the range of 1.7-9.2% and the intralaboratory reproducibility varied between 2.8% and 9.3% for all compounds, except for tylosin A for which more variation was observed resulting in a higher measurement uncertainty. The limit of detection and limit of quantification varied between 1.1 and 20.2 and between 3.5 and 67.3 μg/kg, respectively. This method was used to determine the presence and concentration of the seven antibiotic residues in swine manure sampled from ten different manure pits on farms where the selected antibiotics were used. A link was found between the antibiotics used and detected, except for ceftiofur which is injected at low doses and degraded readily in swine manure and was therefore not recovered in any of the samples. To the best of our knowledge, this is the first method available for the simultaneous extraction and quantification of colistin with other antibiotic classes. Additionally, colistin was never extracted from swine manure before. Another innovative aspect of this method is the simultaneous detection and quantification of five different classes of antibiotic residues in swine manure

  14. [An ultrafast liquid chromatography-tandem mass spectrometric method for simultaneous determination of common artificial synthetic pigments in cooked meat products].

    PubMed

    Chen, Xiaohong; Li, Xiaoping; Zhao, Yonggang; Pan, Shengdong; Jin, Micong

    2015-07-01

    A method based on ultrafast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) has been developed for the simultaneous determination of seven synthetic pigments in cooked meat product. After the cooked meat products were extracted by mixed extraction agent, purified by WAX column, the UFLC separation was performed on a Shim-pack XR-ODS II column (75 mm x 2.0 mm, 2.2 µm) with a linear gradient elution program of acetonitrile and ammonium acetate (AmAc, 5 mmol/L) as the mobile phase. Electrospray ionization was applied and operated in the negative ion mode. The limits of quantitation (LOQs) for the seven synthetic pigments were in the range of 0.7-5.0 µg/kg. The calibration curves showed good linearities for the seven analytes in their detection ranges, and the correlative coefficients (r) were more than 0.999. The recoveries were between 88.2%-106.5% with the RSDs in the range of 1.2%-5.0%. The method is sensitive, reproducible, quick and adapts to the simultaneous determination of the seven synthetic pigments in cooked meat product.

  15. Development of Extraction Methods for the Analysis of Perfluorinated Compounds in Leather with High Performance Liquid Chromatography Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Wang, Youchao; Tang, Chuanjiang; Nie, Jingmei; Xu, Chengtao

    2018-01-01

    Perfluorinated compounds (PFCs), used to provide water, oil, grease, heat and stain repellency to a range of textile and other products, have been found to be persistent in the environment and are associated with adverse effects on humans and wildlife. This study presents the development and validation of an analytical method to determine the simultaneous presence of eleven PFCs in leather using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The perfluorinated compounds were primarily extracted from the samples by a liquid extraction procedure by ultrasonic, in which the parameters were optimized. Then the solid-phase extraction (SPE) is the most important advantages of the developed methodology. The sample volume and elution conditions were optimized by means of an experimental design. The proposed method was applied to determine the PFCs in leather, where the detection limits of the eleven compounds were 0.09-0.96 ng/L, and the recoveries of all compounds spiked at 5 ng/L concentration level were in the range of 65-96%, with a better RSD lower than 19% (n = 7).

  16. Development of an advanced spacecraft tandem mass spectrometer

    NASA Astrophysics Data System (ADS)

    Drew, Russell C.

    1992-03-01

    The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology

  17. Development of an advanced spacecraft tandem mass spectrometer

    NASA Technical Reports Server (NTRS)

    Drew, Russell C.

    1992-01-01

    The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology

  18. Direct determination of trace phthalate esters in alcoholic spirits by spray-inlet microwave plasma torch ionization tandem mass spectrometry.

    PubMed

    Miao, Meng; Zhao, Gaosheng; Xu, Li; Dong, Junguo; Cheng, Ping

    2018-03-01

    A direct analytical method based on spray-inlet microwave plasma torch tandem mass spectrometry was applied to simultaneously determine 4 phthalate esters (PAEs), namely, benzyl butyl phthalate, diethyl phthalate, dipentyl phthalate, and dodecyl phthalate with extremely high sensitivity in spirits without sample treatment. Among the 4 brands of spirit products, 3 kinds of PAE compounds were directly determined at very low concentrations from 1.30 to 114 ng·g -1 . Compared with other online and off-line methods, the spray-inlet microwave plasma torch tandem mass spectrometry technique is extremely simple, rapid, sensitive, and high efficient, providing an ideal screening tool for PAEs in spirits. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Fingerprinting of Cyanobacteria Based on PCR with Primers Derived from Short and Long Tandemly Repeated Repetitive Sequences

    PubMed Central

    Rasmussen, Ulla; Svenning, Mette M.

    1998-01-01

    The presence of repeated DNA (short tandemly repeated repetitive [STRR] and long tandemly repeated repetitive [LTRR]) sequences in the genome of cyanobacteria was used to generate a fingerprint method for symbiotic and free-living isolates. Primers corresponding to the STRR and LTRR sequences were used in the PCR, resulting in a method which generate specific fingerprints for individual isolates. The method was useful both with purified DNA and with intact cyanobacterial filaments or cells as templates for the PCR. Twenty-three Nostoc isolates from a total of 35 were symbiotic isolates from the angiosperm Gunnera species, including isolates from the same Gunnera species as well as from different species. The results show a genetic similarity among isolates from different Gunnera species as well as a genetic heterogeneity among isolates from the same Gunnera species. Isolates which have been postulated to be closely related or identical revealed similar results by the PCR method, indicating that the technique is useful for clustering of even closely related strains. The method was applied to nonheterocystus cyanobacteria from which a fingerprint pattern was obtained. PMID:16349487

  20. Correction methods for underwater turbulence degraded imaging

    NASA Astrophysics Data System (ADS)

    Kanaev, A. V.; Hou, W.; Restaino, S. R.; Matt, S.; Gładysz, S.

    2014-10-01

    The use of remote sensing techniques such as adaptive optics and image restoration post processing to correct for aberrations in a wavefront of light propagating through turbulent environment has become customary for many areas including astronomy, medical imaging, and industrial applications. EO imaging underwater has been mainly concentrated on overcoming scattering effects rather than dealing with underwater turbulence. However, the effects of turbulence have crucial impact over long image-transmission ranges and under extreme turbulence conditions become important over path length of a few feet. Our group has developed a program that attempts to define under which circumstances application of atmospheric remote sensing techniques could be envisioned. In our experiments we employ the NRL Rayleigh-Bénard convection tank for simulated turbulence environment at Stennis Space Center, MS. A 5m long water tank is equipped with heating and cooling plates that generate a well measured thermal gradient that in turn produces various degrees of turbulence. The image or laser beam spot can be propagated along the tank's length where it is distorted by induced turbulence. In this work we report on the experimental and theoretical findings of the ongoing program. The paper will introduce the experimental setup, the techniques used, and the measurements made as well as describe novel methods for postprocessing and correction of images degraded by underwater turbulence.

  1. Stable-Isotope Dilution HPLC-Electrospray Ionization Tandem Mass Spectrometry Method for Quantifying Hydroxyurea in Dried Blood Samples.

    PubMed

    Marahatta, Anu; Megaraj, Vandana; McGann, Patrick T; Ware, Russell E; Setchell, Kenneth D R

    2016-12-01

    Sickle cell anemia (SCA) is a life-threatening blood disorder characterized by the presence of sickle-shaped erythrocytes. Hydroxyurea is currently the only US Food and Drug Administration-approved treatment and there is a need for a convenient method to monitor compliance and hydroxyurea concentrations, especially in pediatric SCA patients. We describe a novel approach to the determination of hydroxyurea concentrations in dried whole blood collected on DMPK-C cards or volumetric absorptive microsampling (VAMS) devices. Hydroxyurea was quantified by electrospray ionization LC-MS/MS using [ 13 C 15 N 2 ]hydroxyurea as the internal standard. Calibrators were prepared in whole blood applied to DMPK-C cards or VAMS devices. Calibration curves for blood hydroxyurea measured from DMPK-C cards and VAMS devices were linear over the range 0.5-60 μg/mL. Interassay and intraassay CVs were <15% for blood collected by both methods, and the limit of detection was 5 ng/mL. Whole blood hydroxyurea was stable for up to 60 days on DMPK-C cards and VAMS devices when frozen at -20 °C or -80 °C. Whole blood hydroxyurea concentrations in samples collected on DMPK-C cards or VAMS devices from SCA patients were in close agreement. This tandem mass spectrometry method permits measurement of hydroxyurea concentrations in small volumes of dried blood applied to either DMPK-C cards or VAMS devices with comparable performance. This method for measuring hydroxyurea from dried blood permits the evaluation of therapeutic drug monitoring, individual pharmacokinetics, and medication adherence using heel/finger-prick samples from pediatric patients with SCA treated with hydroxyurea. © 2016 American Association for Clinical Chemistry.

  2. Simultaneous determination of estrogens and progestogens in honey using high performance liquid chromatography-tandem mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...

  3. Hidden aconite poisoning: identification of yunaconitine and related aconitum alkaloids in urine by liquid chromatography-tandem mass spectrometry.

    PubMed

    Lai, Chi-Kong; Poon, Wing-Tat; Chan, Yan-Wo

    2006-09-01

    Poisoning from aconite occurs worldwide as a result of misuse of the potent plant. Laboratory investigation into suspected intoxication cases is challenging because the content of toxic aconitum alkaloids varies depending on the plant source, market processing, dosing protocol, hydrolytic degradation, and metabolic transformation. Using a triple-quadrupole tandem mass spectrometer, a group screening method was developed based on the mass-fragmentographic scheme of common aconitum alkaloids. The precursor-ion scans of m/z 105 and 135 permitted selective profiling of 14-O-benzoyl-norditerpenoids and the 14-O-anisoyl-norditerpenoids, respectively. Gradient reversed-phase liquid chromatography minimized coelution of isobaric compounds. The screening protocol was applied to a clinical investigation of suspected herbal poisoning. In total, 15 urine samples were thus screened positive for aconitum alkaloid over 5 years. The diagnoses of aconite poisoning in 11 patients were firmly established based on the known prescription history and the positive urine finding. In four patients, without aconitum herbs being listed in the herbal prescriptions, contamination of the herbal remedies by aconite was suspected to be the hidden cause of their acute poisoning. Yunaconitne, a highly toxic aconitum alkaloid, was thus identified in human urine for the first time. The group screening method of aconitum alkaloids in urine is an important diagnostic aid for acute poisoning by aconites of an unclear origin.

  4. Practical Approaches to Forced Degradation Studies of Vaccines.

    PubMed

    Hasija, Manvi; Aboutorabian, Sepideh; Rahman, Nausheen; Ausar, Salvador F

    2016-01-01

    During the early stages of vaccine development, forced degradation studies are conducted to provide information about the degradation properties of vaccine formulations. In addition to supporting the development of analytical methods for the detection of degradation products, these stress studies are used to identify optimal long-term storage conditions and are part of the regulatory requirements for the submission of stability data. In this chapter, we provide detailed methods for forced degradation analysis under thermal, light, and mechanical stress conditions.

  5. Validation of a Chiral Liquid Chromatographic Method for the Degradation Behavior of Flumequine Enantiomers in Mariculture Pond Water.

    PubMed

    Wang, Yan-Fei; Gao, Xiao-Feng; Jin, Huo-Xi; Wang, Yang-Guang; Wu, Wei-Jian; Ouyang, Xiao-Kun

    2016-09-01

    In this work, flumequine (FLU) enantiomers were separated using a Chiralpak OD-H column, with n-hexane-ethanol (20:80, v/v) as the mobile phase at a flow rate of 0.6 mL/min. Solid phase extraction (SPE) was used for cleanup and enrichment. The limit of detection, limit of quantitation, linearity, precision, and intra/interday variation of the chiral high-performance liquid chromatography (HPLC) method were determined. The developed method was then applied to investigate the degradation behavior of FLU enantiomers in mariculture pond water samples. The results showed that the degradation of FLU enantiomers under natural, sterile, or dark conditions was not enantioselective. Chirality 28:649-655, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Comparison of three 15N methods to correct for microbial contamination when assessing in situ protein degradability of fresh forages.

    PubMed

    Kamoun, M; Ammar, H; Théwis, A; Beckers, Y; France, J; López, S

    2014-11-01

    The use of stable (15)N as a marker to determine microbial contamination in nylon bag incubation residues to estimate protein degradability was investigated. Three methods using (15)N were compared: (15)N-labeled forage (dilution method, LF), (15)N enrichment of rumen solids-associated bacteria (SAB), and (15)N enrichment of rumen liquid-associated bacteria (LAB). Herbage from forages differing in protein and fiber contents (early-cut Italian ryegrass, late-cut Italian ryegrass, and red clover) were freeze-dried and ground and then incubated in situ in the rumen of 3 steers for 3, 6, 12, 24, and 48 h using the nylon bag technique. The (15)N-labeled forages were obtained by fertilizing the plots where herbage was grown with (15)NH4 (15)NO3. Unlabeled forages (obtained from plots fertilized with NH4NO3) were incubated at the same time that ((15)NH4)2SO4 was continuously infused into the rumen of the steers, and then pellets of labeled SAB and LAB were isolated by differential centrifugation of samples of ruminal contents. The proportion of bacterial N in the incubation residues increased from 0.09 and 0.45 g bacterial N/g total N at 3 h of incubation to 0.37 and 0.85 g bacterial N/g total N at 48 h of incubation for early-cut and late-cut ryegrass, respectively. There were differences (P < 0.001) between uncorrected N degradability values and those corrected for microbial contamination with all of the methods. Apparent N degradability of the low-N, high-fiber forage (late-cut ryegrass) was 0.51, whereas the corrected values were 0.85, 0.84, and 0.77 for the LF, SAB, and LAB methods, respectively. With early-cut ryegrass and red clover, the differences between uncorrected and corrected values ranged between 6% and 13%, with small differences among the labeling methods. Generally, methods using labeled forage or labeled SAB and LAB provided similar corrected degradability values. The accuracy in estimating the extent of degradation of protein in the rumen from in situ

  7. Design and long-term monitoring of DSC/CIGS tandem solar module

    NASA Astrophysics Data System (ADS)

    Vildanova, M. F.; Nikolskaia, A. B.; Kozlov, S. S.; Shevaleevskiy, O. I.

    2015-11-01

    This paper describes the design and development of tandem dye-sensitized/Cu(In, Ga)Se (DSC/CIGS) PV modules. The tandem PV module comprised of the top DSC module and a bottom commercial 0,8 m2 CIGS module. The top DSC module was made of 10 DSC mini-modules with the field size of 20 × 20 cm2 each. Tandem DSC/CIGS PV modules were used for providing the long-term monitoring of energy yield and electrical parameters in comparison with standalone CIGS modules under outdoor conditions. The outdoor test facility, containing solar modules of both types and a measurement unit, was located on the roof of the Institute of Biochemical Physics in Moscow. The data obtained during monitoring within the 2014 year period has shown the advantages of the designed tandem DSC/CIGS PV-modules over the conventional CIGS modules, especially for cloudy weather and low-intensity irradiation conditions.

  8. Determination of Monensin in Bovine Tissues: A Bridging Study Comparing the Bioautographic Method (FSIS CLG-MON) with a Liquid Chromatography-Tandem Mass Spectrometry Method (OMA 2011.24).

    PubMed

    Mizinga, Kemmy M; Burnett, Thomas J; Brunelle, Sharon L; Wallace, Michael A; Coleman, Mark R

    2018-05-01

    The U.S. Department of Agriculture, Food Safety Inspection Service regulatory method for monensin, Chemistry Laboratory Guidebook CLG-MON, is a semiquantitative bioautographic method adopted in 1991. Official Method of AnalysisSM (OMA) 2011.24, a modern quantitative and confirmatory LC-tandem MS method, uses no chlorinated solvents and has several advantages, including ease of use, ready availability of reagents and materials, shorter run-time, and higher throughput than CLG-MON. Therefore, a bridging study was conducted to support the replacement of method CLG-MON with OMA 2011.24 for regulatory use. Using fortified bovine tissue samples, CLG-MON yielded accuracies of 80-120% in 44 of the 56 samples tested (one sample had no result, six samples had accuracies of >120%, and five samples had accuracies of 40-160%), but the semiquantitative nature of CLG-MON prevented assessment of precision, whereas OMA 2011.24 had accuracies of 88-110% and RSDr of 0.00-15.6%. Incurred residue results corroborated these results, demonstrating improved accuracy (83.3-114%) and good precision (RSDr of 2.6-20.5%) for OMA 2011.24 compared with CLG-MON (accuracy generally within 80-150%, with exceptions). Furthermore, χ2 analysis revealed no statistically significant difference between the two methods. Thus, the microbiological activity of monensin correlated with the determination of monensin A in bovine tissues, and OMA 2011.24 provided improved accuracy and precision over CLG-MON.

  9. Single P-N junction tandem photovoltaic device

    DOEpatents

    Walukiewicz, Wladyslaw [Kensington, CA; Ager, III, Joel W.; Yu, Kin Man [Lafayette, CA

    2012-03-06

    A single P-N junction solar cell is provided having two depletion regions for charge separation while allowing the electrons and holes to recombine such that the voltages associated with both depletion regions of the solar cell will add together. The single p-n junction solar cell includes an alloy of either InGaN or InAlN formed on one side of the P-N junction with Si formed on the other side in order to produce characteristics of a two junction (2J) tandem solar cell through only a single P-N junction. A single P-N junction solar cell having tandem solar cell characteristics will achieve power conversion efficiencies exceeding 30%.

  10. Single P-N junction tandem photovoltaic device

    DOEpatents

    Walukiewicz, Wladyslaw [Kensington, CA; Ager, III, Joel W.; Yu, Kin Man [Lafayette, CA

    2011-10-18

    A single P-N junction solar cell is provided having two depletion regions for charge separation while allowing the electrons and holes to recombine such that the voltages associated with both depletion regions of the solar cell will add together. The single p-n junction solar cell includes an alloy of either InGaN or InAlN formed on one side of the P-N junction with Si formed on the other side in order to produce characteristics of a two junction (2J) tandem solar cell through only a single P-N junction. A single P-N junction solar cell having tandem solar cell characteristics will achieve power conversion efficiencies exceeding 30%.

  11. Efficient Monolithic Perovskite/Silicon Tandem Solar Cell with Cell Area >1 cm(2).

    PubMed

    Werner, Jérémie; Weng, Ching-Hsun; Walter, Arnaud; Fesquet, Luc; Seif, Johannes Peter; De Wolf, Stefaan; Niesen, Bjoern; Ballif, Christophe

    2016-01-07

    Monolithic perovskite/crystalline silicon tandem solar cells hold great promise for further performance improvement of well-established silicon photovoltaics; however, monolithic tandem integration is challenging, evidenced by the modest performances and small-area devices reported so far. Here we present first a low-temperature process for semitransparent perovskite solar cells, yielding efficiencies of up to 14.5%. Then, we implement this process to fabricate monolithic perovskite/silicon heterojunction tandem solar cells yielding efficiencies of up to 21.2 and 19.2% for cell areas of 0.17 and 1.22 cm(2), respectively. Both efficiencies are well above those of the involved subcells. These single-junction perovskite and tandem solar cells are hysteresis-free and demonstrate steady performance under maximum power point tracking for several minutes. Finally, we present the effects of varying the intermediate recombination layer and hole transport layer thicknesses on tandem cell photocurrent generation, experimentally and by transfer matrix simulations.

  12. Tandem Mass Spectrometry for Structural Identification of Sesquiterpene Alkaloids from the Stems of Dendrobium nobile Using LC-QToF.

    PubMed

    Wang, Yan-Hong; Avula, Bharathi; Abe, Naohito; Wei, Feng; Wang, Mei; Ma, Shuang-Cheng; Ali, Zulfiqar; Elsohly, Mahmoud A; Khan, Ikhlas A

    2016-05-01

    Dendrobium nobile is one of the fundamental herbs in traditional Chinese medicine. Sesquiterpene alkaloids are the main active components in this plant. Due to weak ultraviolet absorption and low content in D. nobile, these sesquiterpene alkaloids have not been extensively studied using chromatographic methods. Herein, tandem mass spectrometry combined with liquid chromatography separation provides a tool for the identification and characterization of the alkaloids from D. nobile. A total of nine sesquiterpene alkaloids were characterized by ultrahigh-performance liquid chromatography tandem mass spectrometry. These alkaloids can be classified into two subgroups that are represented by dendrobine and nobilonine. Tandem mass spectrometric studies revealed the fragmentation pathways of these two subgroup alkaloids that were used for the identification and characterization of other alkaloids in D. nobile. Characterization of these alkaloids using accurate mass and diagnostic fragments provided a reliable methodology for the analysis of D. nobile by ultrahigh-performance liquid chromatography tandem mass spectrometry. The limit of detection was defined as the signal-to-noise ratio equal to 3 : 1. Limits of detection of dendrobine and nobilonine were less than 30 ng/mL. The developed method was applied for the analysis of various Dendrobium species and related dietary supplements. Alkaloids were identified from D. nobile, but not detected from commercial samples including 13 other Dendrobium species and the 7 dietary supplements. Georg Thieme Verlag KG Stuttgart · New York.

  13. Protein Inference from the Integration of Tandem MS Data and Interactome Networks.

    PubMed

    Zhong, Jiancheng; Wang, Jianxing; Ding, Xiaojun; Zhang, Zhen; Li, Min; Wu, Fang-Xiang; Pan, Yi

    2017-01-01

    Since proteins are digested into a mixture of peptides in the preprocessing step of tandem mass spectrometry (MS), it is difficult to determine which specific protein a shared peptide belongs to. In recent studies, besides tandem MS data and peptide identification information, some other information is exploited to infer proteins. Different from the methods which first use only tandem MS data to infer proteins and then use network information to refine them, this study proposes a protein inference method named TMSIN, which uses interactome networks directly. As two interacting proteins should co-exist, it is reasonable to assume that if one of the interacting proteins is confidently inferred in a sample, its interacting partners should have a high probability in the same sample, too. Therefore, we can use the neighborhood information of a protein in an interactome network to adjust the probability that the shared peptide belongs to the protein. In TMSIN, a multi-weighted graph is constructed by incorporating the bipartite graph with interactome network information, where the bipartite graph is built with the peptide identification information. Based on multi-weighted graphs, TMSIN adopts an iterative workflow to infer proteins. At each iterative step, the probability that a shared peptide belongs to a specific protein is calculated by using the Bayes' law based on the neighbor protein support scores of each protein which are mapped by the shared peptides. We carried out experiments on yeast data and human data to evaluate the performance of TMSIN in terms of ROC, q-value, and accuracy. The experimental results show that AUC scores yielded by TMSIN are 0.742 and 0.874 in yeast dataset and human dataset, respectively, and TMSIN yields the maximum number of true positives when q-value less than or equal to 0.05. The overlap analysis shows that TMSIN is an effective complementary approach for protein inference.

  14. Photodegradation of multiclass fungicides in the aquatic environment and determination by liquid chromatography-tandem mass spectrometry.

    PubMed

    Celeiro, Maria; Facorro, Rocio; Dagnac, Thierry; Vilar, Vítor J P; Llompart, Maria

    2017-08-01

    The photodegradation behaviour for nine widespread fungicides (benalaxyl, cyprodinil, dimethomorph, fenhexamide, iprovalicarb, kresoxim-methyl, metalaxyl, myclobutanil and tebuconazole) was evaluated in different types of water. Two different systems, direct UV photolysis and UVC/H 2 O 2 advanced oxidation process (AOP), were applied for the photodegradation tests. For the monitoring of the target compound degradation, a method based on direct injection liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. Several fungicide photodegradation by-products were tentatively identified by high-resolution mass spectrometry (HRMS) as well. For the photolysis studies, the efficiency of different types of radiation, UVC (λ = 254 nm) and UVA (λ = 365 nm), was compared. UVC photolysis provided the highest removal with a complete degradation for fenhexamide and kresoxim-methyl, and percentages between 48 and 78% for the other compounds, excluding iprovalicarb and myclobutanil with removals <35%, after 30 min of irradiation. Besides, the photodegradation tests were performed with different initial concentrations of fungicides, and the efficiency of two photoreactor systems was compared. In all cases, the kinetics followed pseudo-first order, and the half-life times could also be calculated. The addition of H 2 O 2 under UVC light allowed an improvement of the reaction kinetics, especially for the most recalcitrant fungicides, obtaining in all cases removals higher than 82% in less than 6 min. Finally, in order to evaluate the suitability of the proposed systems, both UVC photolysis and UVC/H 2 O 2 system were tested in different real water matrices (wastewater, tap water, swimming pool water and river water), showing that the UVC/H 2 O 2 system had the highest removal efficiency in less than 6 min, for all water samples.

  15. Radiation degradation prediction for InGaP solar cells by using appropriate estimation method for displacement threshold energy

    NASA Astrophysics Data System (ADS)

    Okuno, Y.; Okuda, S.; Akiyoshi, M.; Oka, T.; Harumoto, M.; Omura, K.; Kawakita, S.; Imaizumi, M.; Messenger, S. R.; Lee, K. H.; Yamaguchi, M.

    2017-09-01

    InGaP solar cells are not predicted to be susceptible to displacement damage by irradiation with electrons at energies lower than 100 keV from non-ionizing energy loss (NIEL) calculations. However, it is recently observed that InGaP solar cells are shown to degrade by irradiation with 60 keV electrons. This degradation is considered to be caused by radiation defects but is not clear. In this study, the kind of the defects generated by electrons at energies lower than 100 keV is found by deep-level transient spectroscopy (DLTS). The result of DLTS indicates that the prediction of primary knock-on atoms by using the radiation damage model is different from the experiment. In order to suggest the generation mechanism of radiation defects, we propose a new displacement threshold energy (Ed) by using a new technique in which NIEL and the introduction rate of radiation defects are combined. The degradation prediction by using estimated Ed is found to agree well with the degradation of electric power of InGaP solar cells irradiated by low-energy electrons. From the theory of radiation defects, we propose a new obtaining process of suitable degradation prediction by the displacement damage dose method.

  16. Hybrid tandem quantum dot/organic photovoltaic cells with complementary near infrared absorption

    NASA Astrophysics Data System (ADS)

    Kim, Taesoo; Palmiano, Elenita; Liang, Ru-Ze; Hu, Hanlin; Murali, Banavoth; Kirmani, Ahmad R.; Firdaus, Yuliar; Gao, Yangqin; Sheikh, Arif; Yuan, Mingjian; Mohammed, Omar F.; Hoogland, Sjoerd; Beaujuge, Pierre M.; Sargent, Edward H.; Amassian, Aram

    2017-05-01

    Monolithically integrated hybrid tandem solar cells that effectively combine solution-processed colloidal quantum dot (CQD) and organic bulk heterojunction subcells to achieve tandem performance that surpasses the individual subcell efficiencies have not been demonstrated to date. In this work, we demonstrate hybrid tandem cells with a low bandgap PbS CQD subcell harvesting the visible and near-infrared photons and a polymer:fullerene—poly (diketopyrrolopyrrole-terthiophene) (PDPP3T):[6,6]-phenyl-C60-butyric acid methyl ester (PC61BM)—top cell absorbing effectively the red and near-infrared photons of the solar spectrum in a complementary fashion. The two subcells are connected in series via an interconnecting layer (ICL) composed of a metal oxide layer, a conjugated polyelectrolyte, and an ultrathin layer of Au. The ultrathin layer of Au forms nano-islands in the ICL, reducing the series resistance, increasing the shunt resistance, and enhancing the device fill-factor. The hybrid tandems reach a power conversion efficiency (PCE) of 7.9%, significantly higher than the PCE of the corresponding individual single cells, representing one of the highest efficiencies reported to date for hybrid tandem solar cells based on CQD and polymer subcells.

  17. Context-Sensitive Markov Models for Peptide Scoring and Identification from Tandem Mass Spectrometry

    PubMed Central

    Grover, Himanshu; Wallstrom, Garrick; Wu, Christine C.

    2013-01-01

    Abstract Peptide and protein identification via tandem mass spectrometry (MS/MS) lies at the heart of proteomic characterization of biological samples. Several algorithms are able to search, score, and assign peptides to large MS/MS datasets. Most popular methods, however, underutilize the intensity information available in the tandem mass spectrum due to the complex nature of the peptide fragmentation process, thus contributing to loss of potential identifications. We present a novel probabilistic scoring algorithm called Context-Sensitive Peptide Identification (CSPI) based on highly flexible Input-Output Hidden Markov Models (IO-HMM) that capture the influence of peptide physicochemical properties on their observed MS/MS spectra. We use several local and global properties of peptides and their fragment ions from literature. Comparison with two popular algorithms, Crux (re-implementation of SEQUEST) and X!Tandem, on multiple datasets of varying complexity, shows that peptide identification scores from our models are able to achieve greater discrimination between true and false peptides, identifying up to ∼25% more peptides at a False Discovery Rate (FDR) of 1%. We evaluated two alternative normalization schemes for fragment ion-intensities, a global rank-based and a local window-based. Our results indicate the importance of appropriate normalization methods for learning superior models. Further, combining our scores with Crux using a state-of-the-art procedure, Percolator, we demonstrate the utility of using scoring features from intensity-based models, identifying ∼4-8 % additional identifications over Percolator at 1% FDR. IO-HMMs offer a scalable and flexible framework with several modeling choices to learn complex patterns embedded in MS/MS data. PMID:23289783

  18. Breaking the Link between Environmental Degradation and Oil Palm Expansion: A Method for Enabling Sustainable Oil Palm Expansion

    PubMed Central

    Smit, Hans Harmen; Meijaard, Erik; van der Laan, Carina; Mantel, Stephan; Budiman, Arif; Verweij, Pita

    2013-01-01

    Land degradation is a global concern. In tropical areas it primarily concerns the conversion of forest into non-forest lands and the associated losses of environmental services. Defining such degradation is not straightforward hampering effective reduction in degradation and use of already degraded lands for more productive purposes. To facilitate the processes of avoided degradation and land rehabilitation, we have developed a methodology in which we have used international environmental and social sustainability standards to determine the suitability of lands for sustainable agricultural expansion. The method was developed and tested in one of the frontiers of agricultural expansion, West Kalimantan province in Indonesia. The focus was on oil palm expansion, which is considered as a major driver for deforestation in tropical regions globally. The results suggest that substantial changes in current land-use planning are necessary for most new plantations to comply with international sustainability standards. Through visualizing options for sustainable expansion with our methodology, we demonstrate that the link between oil palm expansion and degradation can be broken. Application of the methodology with criteria and thresholds similar to ours could help the Indonesian government and the industry to achieve its pro-growth, pro-job, pro-poor and pro-environment development goals. For sustainable agricultural production, context specific guidance has to be developed in areas suitable for expansion. Our methodology can serve as a template for designing such commodity and country specific tools and deliver such guidance. PMID:24039700

  19. Optical enhancement of a printed organic tandem solar cell using diffractive nanostructures.

    PubMed

    Mayer, Jan A; Offermans, Ton; Chrapa, Marek; Pfannmöller, Martin; Bals, Sara; Ferrini, Rolando; Nisato, Giovanni

    2018-03-19

    Solution processable organic tandem solar cells offer a promising approach to achieve cost-effective, lightweight and flexible photovoltaics. In order to further enhance the efficiency of optimized organic tandem cells, diffractive light-management nanostructures were designed for an optimal redistribution of the light as function of both wavelength and propagation angles in both sub-cells. As the fabrication of these optical structures is compatible with roll-to-roll production techniques such as hot-embossing or UV NIL imprinting, they present an optimal cost-effective solution for printed photovoltaics. Tandem cells with power conversion efficiencies of 8-10% were fabricated in the ambient atmosphere by doctor blade coating, selected to approximate the conditions during roll-to-roll manufacturing. Application of the light management structure onto an 8.7% efficient encapsulated tandem cell boosted the conversion efficiency of the cell to 9.5%.

  20. Thermophilic and thermoacidophilic biopolymer-degrading genes and enzymes from Alicyclobacillus acidocaldarius and related organisms, methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, David N.; Apel, William A.; Thompson, Vicki S.

    Isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius are provided. Further provided are methods of at least partially degrading, cleaving, or removing polysaccharides, lignocellulose, cellulose, hemicellulose, lignin, starch, chitin, polyhydroxybutyrate, heteroxylans, glycosides, xylan-, glucan-, galactan-, or mannan-decorating groups using isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius.

  1. Thermophilic and thermoacidophilic biopolymer-degrading genes and enzymes from Alicyclobacillus acidocaldarius and related organisms, methods

    DOEpatents

    Thompson, David N.; Apel, William A.; Thompson, Vicki S.; Reed, David W.; Lacey, Jeffrey A.; Henriksen, Emily D.

    2015-06-02

    Isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius are provided. Further provided are methods of at least partially degrading, cleaving, or removing polysaccharides, lignocellulose, cellulose, hemicellulose, lignin, starch, chitin, polyhydroxybutyrate, heteroxylans, glycosides, xylan-, glucan-, galactan-, or mannan-decorating groups using isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius.

  2. Thermophilic and thermoacidophilic biopolymer-degrading genes and enzymes from Alicyclobacillus acidocaldarius and related organisms, methods

    DOEpatents

    Thompson, David N.; Apel, William A.; Thompson, Vicki S.; Reed, David W.; Lacey, Jeffrey A.

    2013-10-15

    Isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius are provided. Further provided are methods of at least partially degrading, cleaving, or removing polysaccharides, lignocellulose, cellulose, hemicellulose, lignin, starch, chitin, polyhydroxybutyrate, heteroxylans, glycosides, xylan-, glucan-, galactan-, or mannan-decorating groups using isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius.

  3. Thermophilic and thermoacidophilic biopolymer-degrading genes and enzymes from alicyclobacillus acidocaldarius and related organisms, methods

    DOEpatents

    Thompson, David N [Idaho Falls, ID; Apel, William A [Jackson, WY; Thompson, Vicki S [Idaho Falls, ID; Reed, David W [Idaho Falls, ID; Lacey, Jeffrey A [Idaho Falls, ID; Henriksen, Emily D [Idaho Falls, ID

    2012-06-19

    Isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius are provided. Further provided are methods of at least partially degrading, cleaving, or removing polysaccharides, lignocellulose, cellulose, hemicellulose, lignin, starch, chitin, polyhydroxybutyrate, heteroxylans, glycosides, xylan-, glucan-, galactan-, or mannan-decorating groups using isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius.

  4. Thermophilic and thermoacidophilic biopolymer-degrading genes and enzymes from Alicyclobacillus acidocaldarius and related organisms, methods

    DOEpatents

    Thompson, David N; Apel, William A; Thompson, Vicki S; Reed, David W; Lacey, Jeffrey A; Henriksen, Emily D

    2013-04-23

    Isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius are provided. Further provided are methods of at least partially degrading, cleaving, or removing polysaccharides, lignocellulose, cellulose, hemicellulose, lignin, starch, chitin, polyhydroxybutyrate, heteroxylans, glycosides, xylan-, glucan-, galactan-, or mannan-decorating groups using isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius.

  5. Thermophilic and thermoacidophilic biopolymer-degrading genes and enzymes from alicyclobacillus acidocaldarius and related organisms, methods

    DOEpatents

    Thompson, David N.; Apel, William A.; Thompson, Vicki S.; Reed, David W.; Lacey, Jeffrey A.; Henriksen, Emily D.

    2010-12-28

    Isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius are provided. Further provided are methods of at least partially degrading, cleaving, or removing polysaccharides, lignocellulose, cellulose, hemicellulose, lignin, starch, chitin, polyhydroxybutyrate, heteroxylans, glycosides, xylan-, glucan-, galactan, or mannan-decorating groups using isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius.

  6. Thermophilic and thermoacidophilic biopolymer-degrading genes and enzymes from alicyclobacillus acidocaldarius and related organisms, methods

    DOEpatents

    Thompson, David N; Apel, William A; Thompson, Vicki S; Reed, David W; Lacey, Jeffrey A; Henriksen, Emily D

    2013-07-30

    Isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius are provided. Further provided are methods of at least partially degrading, cleaving, or removing polysaccharides, lignocellulose, cellulose, hemicellulose, lignin, starch, chitin, polyhydroxybutyrate, heteroxylans, glycosides, xylan-, glucan-, galactan-, or mannan-decorating groups using isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius.

  7. Thermophilic and thermoacidophilic biopolymer degrading genes and enzymes from Alicyclobacillus acidocaldarius and related organisms, methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, David N; Apel, William A; Thompson, Vicki S

    Isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius are provided. Further provided are methods of at least partially degrading, cleaving, or removing polysaccharides, lignocellulose, cellulose, hemicellulose, lignin, starch, chitin, polyhydroxybutyrate, heteroxylans, glycosides, xylan-, glucan-, galactan-, or mannan-decorating groups using isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius.

  8. ANALYTICAL METHOD DEVELOPMENT FOR ALACHLOR ESA AND OTHER ACETANILIDE HERBICIDE DEGRADATION PRODUCTS

    EPA Science Inventory

    In 1998, USEPA published a Drinking Water Contaminant Candidate List (CCL) of 50 chemicals and 10 microorganisms. "Alachlor ESA and other acetanilide herbicide degradation products" is listed on the the 1998 CCL. Acetanilide degradation products are generally more water soluble...

  9. Reference scenarios for deforestation and forest degradation in support of REDD: a review of data and methods

    NASA Astrophysics Data System (ADS)

    Olander, Lydia P.; Gibbs, Holly K.; Steininger, Marc; Swenson, Jennifer J.; Murray, Brian C.

    2008-04-01

    Global climate policy initiatives are now being proposed to compensate tropical forest nations for reducing carbon emissions from deforestation and forest degradation (REDD). These proposals have the potential to include developing countries more actively in international greenhouse gas mitigation and to address a substantial share of the world's emissions which come from tropical deforestation. For such a policy to be viable it must have a credible benchmark against which emissions reduction can be calculated. This benchmark, sometimes termed a baseline or reference emissions scenario, can be based directly on historical emissions or can use historical emissions as input for business as usual projections. Here, we review existing data and methods that could be used to measure historical deforestation and forest degradation reference scenarios including FAO (Food and Agricultural Organization of the United Nations) national statistics and various remote sensing sources. The freely available and corrected global Landsat imagery for 1990, 2000 and soon to come for 2005 may be the best primary data source for most developing countries with other coarser resolution high frequency or radar data as a valuable complement for addressing problems with cloud cover and for distinguishing larger scale degradation. While sampling of imagery has been effectively useful for pan-tropical and continental estimates of deforestation, wall-to-wall (or full coverage) allows more detailed assessments for measuring national-level reference emissions. It is possible to measure historical deforestation with sufficient certainty for determining reference emissions, but there must be continued calls at the international level for making high-resolution imagery available, and for financial and technical assistance to help countries determine credible reference scenarios. The data available for past years may not be sufficient for assessing all forms of forest degradation, but new data sources

  10. Modified tandem gratings anastigmatic imaging spectrometer with oblique incidence for spectral broadband

    NASA Astrophysics Data System (ADS)

    Cui, Chengguang; Wang, Shurong; Huang, Yu; Xue, Qingsheng; Li, Bo; Yu, Lei

    2015-09-01

    A modified spectrometer with tandem gratings that exhibits high spectral resolution and imaging quality for solar observation, monitoring, and understanding of coastal ocean processes is presented in this study. Spectral broadband anastigmatic imaging condition, spectral resolution, and initial optical structure are obtained based on geometric aberration theory. Compared with conventional tandem gratings spectrometers, this modified design permits flexibility in selecting gratings. A detailed discussion of the optical design and optical performance of an ultraviolet spectrometer with tandem gratings is also included to explain the advantage of oblique incidence for spectral broadband.

  11. A validated method for rapid determination of dibenzo-p-dioxins/furans (PCDD/Fs), polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in human milk: focus on utility of tandem solid phase extraction (SPE) cleanup.

    PubMed

    Lin, Yuanjie; Feng, Chao; Xu, Qian; Lu, Dasheng; Qiu, Xinlei; Jin, Yu'e; Wang, Guoquan; Wang, Dongli; She, Jianwen; Zhou, Zhijun

    2016-07-01

    An improved method based on tandem solid phase extraction (SPE) cleanup and gas chromatography-high resolution mass spectrometry (GC-HRMS) has been validated for a rapid determination of dibenzo-p-dioxins/furans (PCDD/Fs), dioxin-like polychlorinated biphenyls (PCBs), marker polychlorinated biphenyls (M-PCBs), and polybrominated diphenyl ethers (PBDEs) using a large volume (50 mL) of human milk. This method was well validated for the measurement of these analytes in human milk from the general population with low limits of detection (LODs, 0.004-0.12 ng/g lipid), satisfactory accuracy (75-120 % of recoveries), and precision [less than 10 % of relative standard deviations (RSDs)]. To comprehensively evaluate the performance of this method, a good, presently validated and routinely used method based on an automated sample clean-up system (ASCS, based on the commercial acid multilayer silica, basic alumina, and carbon columns) was used in parallel for comparison. Compared with the ASCS method, this method presented comparable specificity. Additionally, this method, in contrast to ASCS method, highly reduced consumption of solvents (40 mL versus 500 mL), which results in much lower background in the procedural blank, reduced time, and enhanced sample pretreatment throughput. This method was also applied in a pilot study to measure a batch of human milk samples with satisfactory results. Graphical Abstract Characteristics of the application of tandem SPE cleanup for determination of PCDD/Fs, DL-PCBs,M-PCBs and PBDEs in human milk.

  12. Identification, synthesis and structural characterization of process related and degradation impurities of acrivastine and validation of HPLC method.

    PubMed

    Kumar, Ajay; Devineni, Subba Rao; Dubey, Shailender Kumar; Kumar, Pradeep; Srivastava, Vishal; Ambulgekar, Girish; Jain, Mohit; Gupta, Dharmendra Kumar; Singh, Gurmeet; Kumar, Rajesh; Hiriyanna, S G; Kumar, Pramod

    2016-10-17

    Four impurities (Imp-I-IV) were detected using gradient HPLC method in few laboratory batches of acrivastine in the level of 0.03-0.12% and three impurities (Imp-I-III) were found to be known and one (Imp-IV) was unknown. In forced degradation study, the drug is degraded into four degradation products under oxidation and photolytic conditions. Two impurities (Imp-III and -IV) were concurred with process related impurities whereas Imp-V and -VI were identified as new degradation impurities. Based on LC-ESI/MS n study, the chemical structures of new impurities were presumed as 1-[(2E)-3-(4-methylphenyl)-3-{6-[(1E)-3-oxobut-1-en-1-yl]pyridin-2-yl}prop-2-en-1-yl]pyrrolidin-1-ium-1-olate (Imp-IV), 1-{[3-(4-methylphenyl)-3-{6-[(1E)-3-oxobut-1-en-1-yl]pyridin-2-yl}oxiran-2-yl]methyl}pyrrolidin-1-ium-1-olate (Imp-V) and 2-[2-(4-methylphenyl)-3-[(1-oxidopyrrolidin-1-ium-1-yl)methyl]oxiran-2-yl]-6-[(1E)-3-oxobut-1-en-1-yl]pyridin-1-ium-1-olate (Imp-VI), and confirmed by their synthesis followed by spectroscopic analysis, IR, NMR ( 1 H, 13 C) and mass. An efficient and selective high-performance liquid chromatography method has been developed and resolved well the drug related substances on a Phenomenex Gemini C-18 (250×4.6mm, particle size 5μm) column. The mobile phase was composed of sodium dihydrogen phosphate (10mM) and methanol, temperature at 25°C, and a PDA detector set at 254nm used for detection. The method was validated with respect to specificity, linearity, precision, accuracy, and sensitivity and satisfactory results were achieved. Identification, synthesis, characterization of impurities and method validation were first reported in this paper. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. A novel amino acid analysis method using derivatization of multiple functional groups followed by liquid chromatography/tandem mass spectrometry.

    PubMed

    Sakaguchi, Yohei; Kinumi, Tomoya; Yamazaki, Taichi; Takatsu, Akiko

    2015-03-21

    We have developed a novel amino acid analysis method using derivatization of multiple functional groups (amino, carboxyl, and phenolic hydroxyl groups). The amino, carboxyl, and phenolic hydroxyl groups of the amino acids were derivatized with 1-bromobutane so that the hydrophobicities and basicities of the amino acids were improved. The derivatized amino acids, including amino group-modified amino acids, could be detected with high sensitivity using liquid chromatography/tandem mass spectrometry (LC-MS/MS). In this study, 17 amino acids obtained by hydrolyzing proteins and 4 amino group-modified amino acids found in the human body (N,N-dimethylglycine, N-formyl-L-methionine, L-pyroglutamic acid, and sarcosine) were selected as target compounds. The 21 derivatized amino acids could be separated using an octadecyl-silylated silica column within 20 min and simultaneously detected. The detection limits for the 21 amino acids were 5.4-91 fmol, and the calibration curves were linear over the range of 10-100 nmol L(-1) (r(2) > 0.9984) with good repeatability. A confirmatory experiment showed that our proposed method could be applied to the determination of a protein certified reference material using the analysis of 12 amino acids combined with isotope dilution mass spectrometry. Furthermore, the proposed method was successfully applied to a stable isotope-coded derivatization method using 1-bromobutane and 1-bromobutane-4,4,4-d3 for comparative analysis of amino acids in human serum.

  14. Vitamin B12 determination in milk, whey and different by-products of ricotta cheese production by ultra performance liquid chromatography coupled with tandem mass spectrometry

    PubMed Central

    Repossi, Adele; Zironi, Elisa; Gazzotti, Teresa; Serraino, Andrea; Pagliuca, Giampiero

    2017-01-01

    Vitamin B12 (cobalamin) is a metal complex composed of a central cobalt ion bonded to six ligands. It is essential for major biological functions such as protein, fat and carbohydrate metabolism, the maintenance of the central nervous system, and the formation of red blood cells. Since mammals cannot synthesize cobalamin, dietary intake represents the only natural source for humans. Dairy products can provide significant levels of cobalamin; moreover, the European Food Safety Authority (EFSA) panel has set the recommended intake at 4 μg/day for adults. Vitamin B12 content was determined in milk and several matrices related to the process of transformation of the residual whey from Parmigiano Reggiano cheese-making to obtain ricotta cheese. In addition, vitamin B12 degradation during ricotta cheese shelf-life was studied. The analyses were performed using an ultra performance liquid chromatography-tandem mass spectrometry method. Results show that vitamin B12 amount in ricotta from dairy and experimental cheese-making brings respectively 1/8 to 1/4 of the adequate intake in adults established by EFSA. In addition, shelf-life experiment shows that cobalamine is fairly rapidly degraded in ricotta: light effect seems to be significant, even if the light exposure is short. The use of photoprotective packaging material increases B12 shelf-life in the early stage of storage. PMID:29564230

  15. Molecular Mechanism and Genetic Determinants of Buprofezin Degradation

    PubMed Central

    Chen, Xueting; Ji, Junbin; Zhao, Leizhen; Qiu, Jiguo; Dai, Chen; Wang, Weiwu; He, Jian; Jiang, Jiandong; Hong, Qing

    2017-01-01

    ABSTRACT Buprofezin is a widely used insect growth regulator whose residue has been frequently detected in the environment, posing a threat to aquatic organisms and nontarget insects. Microorganisms play an important role in the degradation of buprofezin in the natural environment. However, the relevant catabolic pathway has not been fully characterized, and the molecular mechanism of catabolism is still completely unknown. Rhodococcus qingshengii YL-1 can utilize buprofezin as a sole source of carbon and energy for growth. In this study, the upstream catabolic pathway in strain YL-1 was identified using tandem mass spectrometry. Buprofezin is composed of a benzene ring and a heterocyclic ring. The degradation is initiated by the dihydroxylation of the benzene ring and continues via dehydrogenation, aromatic ring cleavage, breaking of an amide bond, and the release of the heterocyclic ring 2-tert-butylimino-3-isopropyl-1,3,5-thiadiazinan-4-one (2-BI). A buprofezin degradation-deficient mutant strain YL-0 was isolated. A comparative genomic analysis combined with gene deletion and complementation experiments revealed that the gene cluster bfzBA3A4A1A2C is responsible for the upstream catabolic pathway of buprofezin. The bfzA3A4A1A2 cluster encodes a novel Rieske nonheme iron oxygenase (RHO) system that is responsible for the dihydroxylation of buprofezin at the benzene ring; bfzB is involved in dehydrogenation, and bfzC is in charge of benzene ring cleavage. Furthermore, the products of bfzBA3A4A1A2C can also catalyze dihydroxylation, dehydrogenation, and aromatic ring cleavage of biphenyl, flavanone, flavone, and bifenthrin. In addition, a transcriptional study revealed that bfzBA3A4A1A2C is organized in one transcriptional unit that is constitutively expressed in strain YL-1. IMPORTANCE There is an increasing concern about the residue and environmental fate of buprofezin. Microbial metabolism is an important mechanism responsible for the buprofezin degradation in

  16. Tandem photovoltaic solar cells and increased solar energy conversion efficiency

    NASA Technical Reports Server (NTRS)

    Loferski, J. J.

    1976-01-01

    Tandem photovoltaic cells, as proposed by Jackson (1955) to increase the efficiency of solar energy conversion, involve the construction of a system of stacked p/n homojunction photovoltaic cells composed of different semiconductors. It had been pointed out by critics, however, that the total power which could be extracted from the cells in the stack placed side by side was substantially greater than the power obtained from the stacked cells. A reexamination of the tandem cell concept in view of the development of the past few years is conducted. It is concluded that the use of tandem cell systems in flat plate collectors, as originally envisioned by Jackson, may yet become feasible as a result of the development of economically acceptable solar cells for large scale terrestrial power generation.

  17. Degradation of phenol and Cr (VI) wastewater with contact glow discharge electrolysis method and the addition of Fe2+

    NASA Astrophysics Data System (ADS)

    Kurniawan, Raden Ridzki Aditya; Saksono, Nelson

    2017-11-01

    Phenol and Cr (VI) are an organic waste and dangerous heavy metals which generated from a wide variety of industrial processes such as textiles, paints, dyes, and others. For that reason, we need effective waste treatment technologies, one of them is Contact Glow Discharge Electrolysis (CGDE). This method produce reactive species such as radical hidroxyl so as to be able to degradate phenol and Cr(VI) wastewater effectively. This research aims to obtain the effect of Fe 2+ and air bubbles in degradation of phenol and Cr (VI) waste simultaneously. Waste degradation is measured its absorbance with UV-Vis spectrophotometer. In the conditions of 600 Volt voltage, Na2SO4 0.02 M, anode depth of 1.5 cm, the addition of Fe2+ 40 ppm and the addition of air bubbles for 30 minutes was obtained a percentage degradation of phenol 99.47%, Cr (VI) 76.75% and specific energy of 344.473 kJ / mmol.

  18. Efficient Near-Infrared-Transparent Perovskite Solar Cells Enabling Direct Comparison of 4-Terminal and Monolithic Perovskite/Silicon Tandem Cells

    DOE PAGES

    Werner, Jeremie; Barraud, Loris; Walter, Arnaud; ...

    2016-07-30

    Combining market-proven silicon solar cell technology with an efficient wide band gap top cell into a tandem device is an attractive approach to reduce the cost of photovoltaic systems. For this, perovskite solar cells are promising high-efficiency top cell candidates, but their typical device size (<0.2 cm 2), is still far from standard industrial sizes. Here, we present a 1 cm 2 near-infrared transparent perovskite solar cell with 14.5% steadystate efficiency, as compared to 16.4% on 0.25 cm 2. By mechanically stacking these cells with silicon heterojunction cells, we experimentally demonstrate a 4-terminal tandem measurement with a steady-state efficiency ofmore » 25.2%, with a 0.25 cm 2 top cell. The developed top cell processing methods enable the fabrication of a 20.5% efficient and 1.43 cm 2 large monolithic perovskite/silicon heterojunction tandem solar cell, featuring a rear-side textured bottom cell to increase its near-infrared spectral response. Finally, we compare both tandem configurations to identify efficiency-limiting factors and discuss the potential for further performance improvement.« less

  19. Efficient Near-Infrared-Transparent Perovskite Solar Cells Enabling Direct Comparison of 4-Terminal and Monolithic Perovskite/Silicon Tandem Cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Werner, Jeremie; Barraud, Loris; Walter, Arnaud

    Combining market-proven silicon solar cell technology with an efficient wide band gap top cell into a tandem device is an attractive approach to reduce the cost of photovoltaic systems. For this, perovskite solar cells are promising high-efficiency top cell candidates, but their typical device size (<0.2 cm 2), is still far from standard industrial sizes. Here, we present a 1 cm 2 near-infrared transparent perovskite solar cell with 14.5% steadystate efficiency, as compared to 16.4% on 0.25 cm 2. By mechanically stacking these cells with silicon heterojunction cells, we experimentally demonstrate a 4-terminal tandem measurement with a steady-state efficiency ofmore » 25.2%, with a 0.25 cm 2 top cell. The developed top cell processing methods enable the fabrication of a 20.5% efficient and 1.43 cm 2 large monolithic perovskite/silicon heterojunction tandem solar cell, featuring a rear-side textured bottom cell to increase its near-infrared spectral response. Finally, we compare both tandem configurations to identify efficiency-limiting factors and discuss the potential for further performance improvement.« less

  20. Validated Method for the Quantification of Baclofen in Human Plasma Using Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue

    2016-03-01

    A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography-tandem mass spectrometry (LC-MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r(2) > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. A simple and fast method for the inspection of preservatives in cheeses and cream by liquid chromatography- electrospray tandem mass spectrometry.

    PubMed

    Molognoni, Luciano; de Sá Ploêncio, Leandro Antunes; Valese, Andressa Camargo; De Dea Lindner, Juliano; Daguer, Heitor

    2016-01-15

    In this work, a simplified extraction and short time of analysis method for the simultaneous determination of natamycin, nisin and sorbic acid in cheeses and cream by reverse phase liquid chromatography-electrospray-tandem mass spectrometry was developed. Full validation was performed according to the Commission Decision 2002/657/EC criteria and method applicability was checked on several samples, aiming to inspect their compliance with regulatory limits. The method was linear in the concentration ranges of 0-10mg kg(-1) (natamycin), 0-25mg kg(-1) (nisin) and 0 20mg kg(-1) (sorbic acid). Samples of the three most consumed types of cheese (fresh, pasta filata and ripened) in Brazil and cream (ultra high temperature and pasteurized, 20-30% fat content) were assessed. A surprising rate of non-compliance was observed, especially among ripened grated cheeses, since 80% of samples were above the maximum limit for sorbic acid with an average concentration of 2766.3±10.8mg kg(-1). Moreover, a major non-compliance for the cream samples was observed. The proposed method can be applied as an efficient tool for the inspection of preservatives in cheeses and cream. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Determination of Three Corticosteroids in the Biologic Matrix of Vitreous Humor by HPLC-tandem Mass Spectrometry: Method Development and Validation.

    PubMed

    Prieto, Esther; Vispe, Eugenio; Otín-Mallada, Sofía; Garcia-Martin, Elena; Polo-Llorens, Vicente; Fraile, José M; Pablo, Luis E; Mayoral, José A

    2017-02-01

    To develop a simple, specific, and rapid method to determine corticosteroid concentrations in vitreous humor. An analytical method based on high-pressure liquid chromatography-tandem mass spectrometry (HPLC-MS) with a simple extraction procedure was developed. New Zealand albino rabbits (n = 54) received a single (0.1 mL) intravitreal injection of dexamethasone (DXM, 0.1 mg), methylprednisolone (MP, 2 mg), or triamcinolone acetonide (TA, 10 mg). Eyes were enucleated and mean vitreous steroid levels were quantified at 12 h and 1, 2, 3, 7, and 14 days. Corticosteroids were extracted from the vitreous with acetonitrile, and TA was extracted with ethyl acetate, yielding high protein precipitation and clean solution samples. Vitreous samples were analyzed by isocratic HPLC-MS with mobile phase comprising acetonitrile and 2 mM ammonium formate buffer in water, pH 3.5. The linear range was 50-100,000 ng/g with a lower quantification limit of 45 ng/g for DXM and MP, and 50 ng/g for TA. Vitreous levels of DXM and MP were not detectable 14 days post-administration. Vitreous levels of TA were positive and stable throughout the study in both injected and control eyes. The HPLC-MS analytical method is an alternative to HPLC-MS/MS methods, sensitive enough for identifying and quantifying steroids in vitreous humor at a therapeutic dosage scale.

  3. Validation of a Multiresidue Analysis Method for 379 Pesticides in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Shin, Yongho; Lee, Jonghwa; Lee, Jiho; Lee, Junghak; Kim, Eunhye; Liu, Kwang-Hyeon; Lee, Hye Suk; Kim, Jeong-Han

    2018-04-04

    A screening method for simultaneous analysis of 379 pesticides in human serum was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Electrospray ionization with positive/negative switching mode of LC-MS/MS was adopted, and scheduled multiple reaction monitoring for each target compound was established. The limit of quantitation was 10 ng/mL for 94.5% of the total pesticides, and the correlation coefficients of calibration were ≥0.990 for 93.9% of the pesticides. For the sample preparation, scaled-down QuEChERS were used. Serum (100 μL) was extracted with acetonitrile (400 μL), partitioned with magnesium sulfate (40 mg) and sodium chloride (10 mg), and the upper layer was used for analysis without further cleanup steps. For the accuracy and precision tests, most of the pesticides showed excellent results in intra- and interday conditions. In the recovery tests at 10, 50, and 250 ng/mL, 85.8-91.8% of all target compounds satisfied the recovery range of 70-120% (relative standard deviation ≤20%).

  4. Target capture enrichment of nuclear SNP markers for massively parallel sequencing of degraded and mixed samples.

    PubMed

    Bose, Nikhil; Carlberg, Katie; Sensabaugh, George; Erlich, Henry; Calloway, Cassandra

    2018-05-01

    DNA from biological forensic samples can be highly fragmented and present in limited quantity. When DNA is highly fragmented, conventional PCR based Short Tandem Repeat (STR) analysis may fail as primer binding sites may not be present on a single template molecule. Single Nucleotide Polymorphisms (SNPs) can serve as an alternative type of genetic marker for analysis of degraded samples because the targeted variation is a single base. However, conventional PCR based SNP analysis methods still require intact primer binding sites for target amplification. Recently, probe capture methods for targeted enrichment have shown success in recovering degraded DNA as well as DNA from ancient bone samples using next-generation sequencing (NGS) technologies. The goal of this study was to design and test a probe capture assay targeting forensically relevant nuclear SNP markers for clonal and massively parallel sequencing (MPS) of degraded and limited DNA samples as well as mixtures. A set of 411 polymorphic markers totaling 451 nuclear SNPs (375 SNPs and 36 microhaplotype markers) was selected for the custom probe capture panel. The SNP markers were selected for a broad range of forensic applications including human individual identification, kinship, and lineage analysis as well as for mixture analysis. Performance of the custom SNP probe capture NGS assay was characterized by analyzing read depth and heterozygote allele balance across 15 samples at 25 ng input DNA. Performance thresholds were established based on read depth ≥500X and heterozygote allele balance within ±10% deviation from 50:50, which was observed for 426 out of 451 SNPs. These 426 SNPs were analyzed in size selected samples (at ≤75 bp, ≤100 bp, ≤150 bp, ≤200 bp, and ≤250 bp) as well as mock degraded samples fragmented to an average of 150 bp. Samples selected for ≤75 bp exhibited 99-100% reportable SNPs across varied DNA amounts and as low as 0.5 ng. Mock degraded samples at 1

  5. Prognostics of slurry pumps based on a moving-average wear degradation index and a general sequential Monte Carlo method

    NASA Astrophysics Data System (ADS)

    Wang, Dong; Tse, Peter W.

    2015-05-01

    Slurry pumps are commonly used in oil-sand mining for pumping mixtures of abrasive liquids and solids. These operations cause constant wear of slurry pump impellers, which results in the breakdown of the slurry pumps. This paper develops a prognostic method for estimating remaining useful life of slurry pump impellers. First, a moving-average wear degradation index is proposed to assess the performance degradation of the slurry pump impeller. Secondly, the state space model of the proposed health index is constructed. A general sequential Monte Carlo method is employed to derive the parameters of the state space model. The remaining useful life of the slurry pump impeller is estimated by extrapolating the established state space model to a specified alert threshold. Data collected from an industrial oil sand pump were used to validate the developed method. The results show that the accuracy of the developed method improves as more data become available.

  6. Rapid quantitative analysis of 8-iso-prostaglandin-F(2alpha) using liquid chromatography-tandem mass spectrometry and comparison with an enzyme immunoassay method.

    PubMed

    Dahl, Jeffrey H; van Breemen, Richard B

    2010-09-15

    A rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed for the measurement of urinary 8-iso-prostaglandin F(2alpha) (8-iso-PGF(2alpha)), a biomarker of lipid peroxidation. Because urine contains numerous F(2) prostaglandin isomers, each with identical mass and similar mass spectrometric fragmentation patterns, chromatographic separation of 8-iso-PGF(2alpha) from its isomers is necessary for its quantitative analysis using MS/MS. We were able to achieve this separation using an isocratic LC method with a run time of less than 9min, which is at least threefold faster than previous methods, while maintaining sensitivity, accuracy, precision, and reliability. The limits of detection and quantitation were 53 and 178pg/ml urine, respectively. We compared our method with a commercially available affinity purification and enzyme immunoassay kit and found both assays to be in agreement. Despite the high sensitivity of the enzyme immunoassay method, it is more expensive and has a narrower dynamic range than LC-MS/MS. Our method was optimized for rapid measurement of 8-iso-PGF(2alpha) in urine, and it is ideally suited for clinical sample analysis. 2010 Elsevier Inc. All rights reserved.

  7. Ultra-trace level determination of diquat and paraquat residues in surface and drinking water using ion-pair liquid chromatography with tandem mass spectrometry: a comparison of direct injection and solid-phase extraction methods.

    PubMed

    Oh, Jin-Aa; Lee, Jun-Bae; Lee, Soo-Hyung; Shin, Ho-Sang

    2014-10-01

    Direct injection and solid-phase extraction methods for the determination of diquat and paraquat in surface and drinking water were developed using liquid chromatography with tandem mass spectrometry. The signal intensities of analytes based on six ion-pairing reagents were compared with each other, and 12.5 mM nonafluoropentanoic acid was selected as the best suited amongst them. A clean-up method was developed using Oasis hydrophilic-lipophilic balance; this was compared to the direct injection method, with respect to limits of detection, interference, precision, and accuracy. Limits of quantification of diquat and paraquat were 0.03 and 0.01 μg/L using the direct injection method, and 0.002 and 0.001 μg/L using the hydrophilic-lipophilic balance method. When the hydrophilic-lipophilic balance method was used to analyze target compounds in 114 surface water and 30 drinking water samples, paraquat and diquat were detected within a concentration range of 0.001-0.12 and 0.002-0.038 μg/L in surface water, respectively. When the direct injection method was used to analyze target compounds in the same samples, the detected concentrations of paraquat and diquat were within 25% in samples being >0.015 μg/L using the hydrophilic-lipophilic balance method. The liquid chromatography with tandem mass spectrometry method using direct injection can thus be used for routine monitoring of paraquat and diquat in surface and drinking water. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Development of liquid chromatography-tandem mass spectrometry methods for the quantitation of Anisakis simplex proteins in fish.

    PubMed

    Fæste, Christiane Kruse; Moen, Anders; Schniedewind, Björn; Haug Anonsen, Jan; Klawitter, Jelena; Christians, Uwe

    2016-02-05

    The parasite Anisakis simplex is present in many marine fish species that are directly used as food or in processed products. The anisakid larvae infect mostly the gut and inner organs of fish but have also been shown to penetrate into the fillet. Thus, human health can be at risk, either by contracting anisakiasis through the consumption of raw or under-cooked fish, or by sensitisation to anisakid proteins in processed food. A number of different methods for the detection of A. simplex in fish and products thereof have been developed, including visual techniques and PCR for larvae tracing, and immunological assays for the determination of proteins. The recent identification of a number of anisakid proteins by mass spectrometry-based proteomics has laid the groundwork for the development of two quantitative liquid chromatography-tandem mass spectrometry methods for the detection of A. simplex in fish that are described in the present study. Both, the label-free semi-quantitative nLC-nESI-Orbitrap-MS/MS (MS1) and the heavy peptide-applying absolute-quantitative (AQUA) LC-TripleQ-MS/MS (MS2) use unique reporter peptides derived from anisakid hemoglobin and SXP/RAL-2 protein as analytes. Standard curves in buffer and in salmon matrix showed limits of detection at 1μg/mL and 10μg/mL for MS1 and 0.1μg/mL and 2μg/mL for MS2. Preliminary method validation included the assessment of sensitivity, repeatability, reproducibility, and applicability to incurred and naturally-contaminated samples for both assays. By further optimization and full validation in accordance with current recommendations the LC-MS/MS methods could be standardized and used generally as confirmative techniques for the detection of A. simplex protein in fish. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Validation of a liquid chromatography-tandem mass spectrometry method for the identification and quantification of 5-nitroimidazole drugs and their corresponding hydroxy metabolites in lyophilised pork meat.

    PubMed

    Zeleny, Reinhard; Harbeck, Stefan; Schimmel, Heinz

    2009-01-09

    A liquid chromatography-electrospray ionisation tandem mass spectrometry method for the simultaneous detection and quantitation of 5-nitroimidazole veterinary drugs in lyophilised pork meat, the chosen format of a candidate certified reference material, has been developed and validated. Six analytes have been included in the scope of validation, i.e. dimetridazole (DMZ), metronidazole (MNZ), ronidazole (RNZ), hydroxymetronidazole (MNZOH), hydroxyipronidazole (IPZOH), and 2-hydroxymethyl-1-methyl-5-nitroimidazole (HMMNI). The analytes were extracted from the sample with ethyl acetate, chromatographically separated on a C(18) column, and finally identified and quantified by tandem mass spectrometry in the multiple reaction monitoring mode (MRM) using matrix-matched calibration and (2)H(3)-labelled analogues of the analytes (except for MNZOH, where [(2)H(3)]MNZ was used). The method was validated in accordance with Commission Decision 2002/657/EC, by determining selectivity, linearity, matrix effect, apparent recovery, repeatability and intermediate precision, decision limits and detection capabilities, robustness of sample preparation method, and stability of extracts. Recovery at 1 microg/kg level was at 100% (estimates in the range of 101-107%) for all analytes, repeatabilities and intermediate precisions at this level were in the range of 4-12% and 2-9%, respectively. Linearity of calibration curves in the working range 0.5-10 microg/kg was confirmed, with r values typically >0.99. Decision limits (CCalpha) and detection capabilities (CCbeta) according to ISO 11843-2 (calibration curve approach) were 0.29-0.44 and 0.36-0.54 microg/kg, respectively. The method reliably identifies and quantifies the selected nitroimidazoles in the reconstituted pork meat in the low and sub-microg/kg range and will be applied in an interlaboratory comparison for determining the mass fraction of the selected nitroimidazoles in the candidate reference material currently developed at

  10. Development of a liquid chromatography–tandem mass spectrometry method for the determination of sulfonamides, trimethoprim and dapsone in honey and validation according to Commission Decision 2002/657/EC for banned compounds [corrected].

    PubMed

    Economou, Anastasios; Petraki, Olympia; Tsipi, Despina; Botitsi, Eleni

    2012-08-15

    This work reports a sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for identification and quantification of seven sulfonamides, trimethoprim and dapsone in honey. The method is based on a solid-phase extraction (SPE) step of the target analytes with Oasis HLB cartridges after acidic hydrolysis of the honey sample to liberate the sugar-bound sulfonamides. Analysis was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive electro-spray ionization (ESI) mode with two different isotopically labeled internal standards with the view to improve the quantitative performance of the method. The method validation has been performed according to the Commission Decision 2002/657/EC; the average recoveries, measured at three concentration levels (1.5, 2.5 and 5.0 μg kg(-1)), have been estimated in the range 70 to 106% while the respective % relative standard deviations of the within-laboratory reproducibility ranged from 6 to 18%. Mean values of the expanded uncertainties calculated were in the range 22-41% at the 99% confidence level. Decision limit (CCα) and detection capability (CCβ) values were in the ranges 0.4-0.9 and 0.7-1.4 μg kg(-1), respectively. Matrix effects have been investigated demonstrating a moderate signal suppression/enhancement for most of the target compounds. The method described has been successfully applied to the analysis of honey samples; sulfamethoxazole, sulfathiazole and trimethoprim were detected in some cases. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. An improved method for determination of fumigant degradation half-life in soil

    USDA-ARS?s Scientific Manuscript database

    Using the current approach, measurement of fumigant degradation half-lives under realistic soil conditions is problematic due to the large headspace that is necessary above the soil during incubation. This results in a poor degree of contact between the fumigant and the soil’s degrading surfaces; di...

  12. Quantitative thin-layer chromatography/mass spectrometry analysis of caffeine using a surface sampling probe electrospray ionization tandem mass spectrometry system.

    PubMed

    Ford, Michael J; Deibel, Michael A; Tomkins, Bruce A; Van Berkel, Gary J

    2005-07-15

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 mum/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 muL) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by approximately 8% or more) than the literature values.

  13. Bacteria-mediated bisphenol A degradation.

    PubMed

    Zhang, Weiwei; Yin, Kun; Chen, Lingxin

    2013-07-01

    Bisphenol A (BPA) is an important monomer in the manufacture of polycarbonate plastics, food cans, and other daily used chemicals. Daily and worldwide usage of BPA and BPA-contained products led to its ubiquitous distribution in water, sediment/soil, and atmosphere. Moreover, BPA has been identified as an environmental endocrine disruptor for its estrogenic and genotoxic activity. Thus, BPA contamination in the environment is an increasingly worldwide concern, and methods to efficiently remove BPA from the environment are urgently recommended. Although many factors affect the fate of BPA in the environment, BPA degradation is mainly depended on the metabolism of bacteria. Many BPA-degrading bacteria have been identified from water, sediment/soil, and wastewater treatment plants. Metabolic pathways of BPA degradation in specific bacterial strains were proposed, based on the metabolic intermediates detected during the degradation process. In this review, the BPA-degrading bacteria were summarized, and the (proposed) BPA degradation pathway mediated by bacteria were referred.

  14. Validation of a headspace trap gas chromatography and mass spectrometry method for the quantitative analysis of volatile compounds from degraded rapeseed oil.

    PubMed

    Sghaier, Lilia; Cordella, Christophe B Y; Rutledge, Douglas N; Watiez, Mickaël; Breton, Sylvie; Sassiat, Patrick; Thiebaut, Didier; Vial, Jérôme

    2016-05-01

    Due to lipid oxidation, off-flavors, characterized by a fishy odor, are emitted during the heating of rapeseed oil in a fryer and affect the flavor of rapeseed oil even at low concentrations. Thus, there is a need for analytical methods to identify and quantify these products. To study the headspace composition of degraded rapeseed oil, and more specifically the compounds responsible for the fishy odor, a headspace trap gas chromatography with mass spectrometry method was developed and validated. Six volatile compounds formed during the degradation of rapeseed oil were quantified: 1-penten-3-one, (Z)-4-heptenal, hexanal, nonanal, (E,E)-heptadienal, and (E)-2-heptenal. Validation using accuracy profiles allowed us to determine the valid ranges of concentrations for each compound, with acceptance limits of 40% and tolerance limits of 80%. This method was then successfully applied to real samples of degraded oils. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Use of tandem circulation wells to measure hydraulic conductivity without groundwater extraction

    NASA Astrophysics Data System (ADS)

    Goltz, Mark N.; Huang, Junqi; Close, Murray E.; Flintoft, Mark J.; Pang, Liping

    2008-09-01

    Conventional methods to measure the hydraulic conductivity of an aquifer on a relatively large scale (10-100 m) require extraction of significant quantities of groundwater. This can be expensive, and otherwise problematic, when investigating a contaminated aquifer. In this study, innovative approaches that make use of tandem circulation wells to measure hydraulic conductivity are proposed. These approaches measure conductivity on a relatively large scale, but do not require extraction of groundwater. Two basic approaches for using circulation wells to measure hydraulic conductivity are presented; one approach is based upon the dipole-flow test method, while the other approach relies on a tracer test to measure the flow of water between two recirculating wells. The approaches are tested in a relatively homogeneous and isotropic artificial aquifer, where the conductivities measured by both approaches are compared to each other and to the previously measured hydraulic conductivity of the aquifer. It was shown that both approaches have the potential to accurately measure horizontal and vertical hydraulic conductivity for a relatively large subsurface volume without the need to pump groundwater to the surface. Future work is recommended to evaluate the ability of these tandem circulation wells to accurately measure hydraulic conductivity when anisotropy and heterogeneity are greater than in the artificial aquifer used for these studies.

  16. Determination of ribavirin in chicken muscle by quick, easy, cheap, effective, rugged and safe method and liquid chromatography-tandem mass spectrometry.

    PubMed

    Wu, Yin-Liang; Chen, Ruo-Xia; Zhu, Lie; Lv, Yan; Zhu, Yong; Zhao, Jian

    2016-02-15

    A new analytical method for the determination of ribavirin in chicken muscle using a QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method and liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed and validated. Samples were extracted with acidified methanol (methanol:acetic acid, 99:1, v/v). The extract was further purified by QuEChERS method using primary-secondary amine (PSA) and C18. Finally, the extract was dried by nitrogen under 45°C and reconstituted in water. The separation was performed on a Hypercarb analytical column under a gradient elution. The mobile phase was composed of water buffered with ammonium acetate (2.0mM) and acetonitrile. The proposed method was validated according to the European Commission Decision 2002/657/EC. The values of the decision limit (CCα) and the detection capability (CCβ) were 1.1 and 1.5μg/kg, respectively. The mean recoveries of ribavirin ranged from 94.2% to 99.2%. The repeatability (expressed as coefficient of variation, CVr) of the method ranged from 4.5% to 4.9% and the reproducibility (CVR) of the method ranged from 4.8% to 5.4%. The method is demonstrated to be suitable for the determination of ribavirin in chicken muscle in conformity with the current EU performance requirements through validation. The total time required for the analysis of one sample, including sample preparation, was about 45min. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Rapid liquid chromatography-tandem mass spectrometry analysis of 4-hydroxynonenal for the assessment of oxidative degradation and safety of vegetable oils.

    PubMed

    Gabbanini, Simone; Matera, Riccardo; Valvassori, Alice; Valgimigli, Luca

    2015-04-15

    A novel method for the UHPLC-MS/MS analysis of (E)-4-hydroxynonenal (4-HNE) is described. The method is based on derivatization of 4-HNE with pentafluorophenylhydrazine (1) or 4-trifluoromethylphenylhydrazine (2) in acetonitrile in the presence of trifluoroacetic acid as catalyst at room temperature and allows complete analysis of one sample of vegetable oil in only 21 min, including sample preparation and chromatography. The method involving hydrazine 1, implemented in an ion trap instrument with analysis of the transition m/z 337→154 showed LOD=10.9 nM, average accuracy of 101% and precision ranging 2.5-4.0% RSD intra-day (2.7-4.1% RSD inter-day), with 4-HNE standard solutions. Average recovery from lipid matrices was 96.3% from vaseline oil, 91.3% from sweet almond oil and 105.3% from olive oil. The method was tested on the assessment of safety and oxidative degradation of seven samples of dietary oil (soybean, mixed seeds, corn, peanut, sunflower, olive) and six cosmetic-grade oils (avocado, blackcurrant, apricot kernel, echium, sesame, wheat germ) and effectively detected increased 4-HNE levels in response to chemical (Fenton reaction), photochemical, or thermal stress and aging, aimed at mimicking typical oxidation associated with storage or industrial processing. The method is a convenient, cost-effective and reliable tool to assess quality and safety of vegetable oils. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Degradation of components in drug formulations: a comparison between HPLC and DSC methods.

    PubMed

    Ceschel, G C; Badiello, R; Ronchi, C; Maffei, P

    2003-08-08

    Information about the stability of drug components and drug formulations is needed to predict the shelf-life of the final products. The studies on the interaction between the drug and the excipients may be carried out by means of accelerated stability tests followed by analytical determination of the active principle (HPLC and other methods) and by means of the differential scanning calorimetry (DSC). This research has been focused to the acetyl salicylic acid (ASA) physical-chemical characterisation by using DSC method in order to evaluate its compatibility with some of the most used excipients. It was possible to show, with the DSC method, the incompatibility of magnesium stearate with ASA; the HPLC data confirm the reduction of ASA concentration in the presence of magnesium stearate. With the other excipients the characteristic endotherms of the drug were always present and no or little degradation was observed with the accelerated stability tests. Therefore, the results with the DSC method are comparable and in good agreement with the results obtained with other methods.

  19. Residue analysis and persistence evaluation of fipronil and its metabolites in cotton using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Wu, Xiaohu; Yu, Yang; Xu, Jun; Dong, Fengshou; Liu, Xingang; Du, Pengqiang; Wei, Dongmei; Zheng, Yongquan

    2017-01-01

    A simple residue analytical method based on the QuEChERS approach and high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) detection was developed for the analysis of fipronil and its three metabolites in cottonseed, cotton plant and soil. The average recoveries of four test compounds from all three matrices were 78.6-108.9% at the level of 0.005 to 0.5 mg/kg, with an RSD in the range of 0.6 to 13.7%. The limit of quantification (LOQ) of the four test compounds ranged from 0.005 to 0.01 mg/kg. The results of the residual dynamics experiments showed that fipronil dissipated rapidly in cotton plants and soil and that oxidation and photolysis were the main degradation pathways. Moreover, the bi-exponential models demonstrated a good fit of the measured data for fipronil in cotton plants and soil, with R2 in the range of 0.8989 to 0.9989. Furthermore, a total of 40 samples of cottonseed from Shandong Province were analyzed, and all of the samples were free from the four test compound residues.

  20. Residue analysis and persistence evaluation of fipronil and its metabolites in cotton using high-performance liquid chromatography-tandem mass spectrometry

    PubMed Central

    Wu, Xiaohu; Yu, Yang; Xu, Jun; Dong, Fengshou; Liu, Xingang; Du, Pengqiang; Wei, Dongmei; Zheng, Yongquan

    2017-01-01

    A simple residue analytical method based on the QuEChERS approach and high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) detection was developed for the analysis of fipronil and its three metabolites in cottonseed, cotton plant and soil. The average recoveries of four test compounds from all three matrices were 78.6–108.9% at the level of 0.005 to 0.5 mg/kg, with an RSD in the range of 0.6 to 13.7%. The limit of quantification (LOQ) of the four test compounds ranged from 0.005 to 0.01 mg/kg. The results of the residual dynamics experiments showed that fipronil dissipated rapidly in cotton plants and soil and that oxidation and photolysis were the main degradation pathways. Moreover, the bi-exponential models demonstrated a good fit of the measured data for fipronil in cotton plants and soil, with R2 in the range of 0.8989 to 0.9989. Furthermore, a total of 40 samples of cottonseed from Shandong Province were analyzed, and all of the samples were free from the four test compound residues. PMID:28291815

  1. Electrooxidative Tandem Cyclization of Activated Alkynes with Sulfinic Acids To Access Sulfonated Indenones

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wen, Jiangwei; Shi, Wenyan; Zhang, Fan

    An,electrooxidative direct arylsulfonlylation of yones sulfintc acids via a radical tandem cyclization strategy has been developed for the construction of sulfonated ilicIenones:under oxidant, free conditions. This method provides a simple and efficient approach to prepare various sulfonylindenones in good to,excellent:Tyidds,, demonstrating the tremendous prospect of utilizing electrocatalysis in oxidative coupling, Notably, this reaction could Be easily scaled up with good, efficiency.

  2. Tunable color parallel tandem organic light emitting devices with carbon nanotube and metallic sheet interlayers

    NASA Astrophysics Data System (ADS)

    Oliva, Jorge; Papadimitratos, Alexios; Desirena, Haggeo; De la Rosa, Elder; Zakhidov, Anvar A.

    2015-11-01

    Parallel tandem organic light emitting devices (OLEDs) were fabricated with transparent multiwall carbon nanotube sheets (MWCNT) and thin metal films (Al, Ag) as interlayers. In parallel monolithic tandem architecture, the MWCNT (or metallic films) interlayers are an active electrode which injects similar charges into subunits. In the case of parallel tandems with common anode (C.A.) of this study, holes are injected into top and bottom subunits from the common interlayer electrode; whereas in the configuration of common cathode (C.C.), electrons are injected into the top and bottom subunits. Both subunits of the tandem can thus be monolithically connected functionally in an active structure in which each subunit can be electrically addressed separately. Our tandem OLEDs have a polymer as emitter in the bottom subunit and a small molecule emitter in the top subunit. We also compared the performance of the parallel tandem with that of in series and the additional advantages of the parallel architecture over the in-series were: tunable chromaticity, lower voltage operation, and higher brightness. Finally, we demonstrate that processing of the MWCNT sheets as a common anode in parallel tandems is an easy and low cost process, since their integration as electrodes in OLEDs is achieved by simple dry lamination process.

  3. Tandem betatron

    DOEpatents

    Keinigs, Rhonald K.

    1992-01-01

    Two betatrons are provided in tandem for alternately accelerating an electron beam to avoid the single flux swing limitation of conventional betatrons and to accelerate the electron beam to high energies. The electron beam is accelerated in a first betatron during a period of increasing magnetic flux. The eletron beam is extracted from the first betatron as a peak magnetic flux is reached and then injected into a second betatron at a time of minimum magnetic flux in the second betatron. The cycle may be repeated until the desired electron beam energy is obtained. In one embodiment, the second betatron is axially offset from the first betatron to provide for electron beam injection directly at the axial location of the beam orbit in the second betatron.

  4. Application of contact glow discharge electrolysis method for degradation of batik dye waste Remazol Red by the addition of Fe2+ ion

    NASA Astrophysics Data System (ADS)

    Saksono, Nelson; Puspita, Indah; Sukreni, Tulus

    2017-03-01

    Contact Glow Discharge Electrolysis (CGDE) has been shown to degrade much weight organic compounds such as dyes because the production of hydroxil radical (•OH) is excess. This research aims to degrade batik dye waste Remazol Red, using CGDE method with the addition of Fe2+ ion. The addition of iron salt compounds has proven to increase process efficiency. Dye degradation is known by measure its absorbances with Spectrophotometer UV-Vis. The result of study showed that percentage degradation was 99.92% in 20 minutes which obtained by using Na2SO4 0.01 M, with addition FeSO4 0,1 gram, applied voltage 860 volt, and 1 wolfram anode 5 mm depth.

  5. Quantitative Acylcarnitine Determination by UHPLC-MS/MS – Going Beyond Tandem MS Acylcarnitine “Profiles”

    PubMed Central

    Minkler, Paul E.; Stoll, Maria S.K.; Ingalls, Stephen T.; Kerner, Janos; Hoppel, Charles L.

    2016-01-01

    Tandem MS “profiling” of acylcarnitines and amino acids was conceived as a first-tier screening method, and its application to expanded newborn screening has been enormously successful. However, unlike amino acid screening (which uses amino acid analysis as its second-tier validation of screening results), acylcarnitine “profiling” also assumed the role of second-tier validation, due to the lack of a generally accepted second-tier acylcarnitine determination method. In this report, we present results from the application of our validated UHPLC-MS/MS second-tier method for the quantification of total carnitine, free carnitine, butyrobetaine, and acylcarnitines to patient samples with known diagnoses: malonic acidemia, short-chain acyl-CoA dehydrogenase deficiency (SCADD) or isobutyryl-CoA dehydrogenase deficiency (IBD), 3-methyl-crotonyl carboxylase deficiency (3-MCC) or β-ketothiolase deficiency (BKT), and methylmalonic acidemia (MMA). We demonstrate the assay’s ability to separate constitutional isomers and diastereomeric acylcarnitines and generate values with a high level of accuracy and precision. These capabilities are unavailable when using tandem MS “profiles”. We also show examples of research interest, where separation of acylcarnitine species and accurate and precise acylcarnitine quantification is necessary. PMID:26458767

  6. Tandem resonator reflectance modulator

    DOEpatents

    Fritz, I.J.; Wendt, J.R.

    1994-09-06

    A wide band optical modulator is grown on a substrate as tandem Fabry-Perot resonators including three mirrors spaced by two cavities. The absorption of one cavity is changed relative to the absorption of the other cavity by an applied electric field, to cause a change in total reflected light, as light reflecting from the outer mirrors is in phase and light reflecting from the inner mirror is out of phase with light from the outer mirrors. 8 figs.

  7. An ultra-pressure liquid chromatography-tandem mass spectrometry method for the simultaneous determination of three physalins in rat plasma and its application to pharmacokinetic study of Physalis alkekengi var. franchetii (Chinese lantern) in rats.

    PubMed

    Zheng, Yunliang; Chen, Yong; Ren, Yiping; Luan, Lianjun; Wu, Yongjiang

    2012-01-25

    An ultra-high pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the quantification of three major ingredients in Chinese lantern preparations (CLP) in rat plasma. Following extraction by ethyl acetate, the analytes were separated on an Acquity UPLC BEH Shield RP C(18) column using a gradient mobile phase system of acetonitrile-water. Electrospray ionization (ESI) tandem interface was employed prior to mass spectrometric detection. The calibration curves were linear over the range of 5.0-500.0 ng/ml for physalin D, 2.3-230.0 ng/ml for physalin G and 0.71-71.0 ng/ml for 4,7-didehydroneophysalin B. The average extraction recoveries, examined at four concentration levels, carried from 57.1% to 76.9%, and the accuracies ranged from 94.0% to 113.3% with precision (RSD) <15%. The validated method was successfully applied to the determination of the three physalins in rat plasma after intragastric administration of CLP suspension. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Toward a high-throughput method for determining vicine and convicine levels in faba bean seeds using flow injection analysis combined with tandem mass spectrometry.

    PubMed

    Purves, Randy W; Khazaei, Hamid; Vandenberg, Albert

    2018-08-01

    Although faba bean provides environmental and health benefits, vicine and convicine (v-c) limit its use as a source of vegetable protein. Crop improvement efforts to minimize v-c concentration require low-cost, rapid screening methods to distinguish between high and low v-c genotypes to accelerate development of new cultivars and to detect out-crossing events. To assist crop breeders, we developed a unique and rapid screening method that uses a 60 s instrumental analysis step to accurately distinguish between high and low v-c genotypes. The method involves flow injection analysis (FIA) coupled with tandem mass spectrometry (i.e., selective reaction monitoring, SRM). Using seeds with known v-c levels as calibrants, measured v-c levels were comparable with liquid chromatography (LC)-SRM results and the method was used to screen 370 faba bean genotypes. Widespread use of FIA-SRM will accelerate breeding of low v-c faba bean, thereby alleviating concerns about anti-nutritional effects of v-c in this crop. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Comparison of pulse glow discharge-ion mobility spectrometry and liquid chromatography with tandem mass spectrometry based on multiplug filtration cleanup for the analysis of tricaine mesylate residues in fish and water.

    PubMed

    Zou, Nan; Chen, Ronghua; Qin, Yuhong; Song, Shuangyu; Tang, Xinglin; Pan, Canping

    2016-09-01

    Analytical methods based on multiplug filtration cleanup coupled with pulse glow discharge-ion mobility spectrometry and liquid chromatography tandem mass spectrometry were developed for the analysis of tricaine mesylate residue in fish and fish-raising water samples. A silica fiber holder and an appropriate new interface were designed to make the direct introduction of the fiber into the pulse glow discharge-ion mobility spectrometry introduction mechanism. The multiplug filtration cleanup method with adsorption mixtures was optimized for the determination of tricaine mesylate in fish samples. Good linear relationships were obtained by the two methods. For fish samples, limits of detection were 6 and 0.6 μg/kg by ion mobility spectrometry and liquid chromatography with tandem mass spectrometry, respectively. The matrix effect of the established liquid chromatography tandem mass spectrometry method was negligible for fish samples but that of the ion mobility spectrometry method was not. The two methods were compared. The ion mobility spectrometry system could be used a rapid screening tool on site with the advantage of rapidity, simplicity, and portability, and the liquid chromatography tandem mass spectrometry system could be used for validation in laboratory conditions with the advantage of lower limit of detection, stability, and precision. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Using long ssDNA polynucleotides to amplify STRs loci in degraded DNA samples

    PubMed Central

    Pérez Santángelo, Agustín; Corti Bielsa, Rodrigo M.; Sala, Andrea; Ginart, Santiago; Corach, Daniel

    2017-01-01

    Obtaining informative short tandem repeat (STR) profiles from degraded DNA samples is a challenging task usually undermined by locus or allele dropouts and peak-high imbalances observed in capillary electrophoresis (CE) electropherograms, especially for those markers with large amplicon sizes. We hereby show that the current STR assays may be greatly improved for the detection of genetic markers in degraded DNA samples by using long single stranded DNA polynucleotides (ssDNA polynucleotides) as surrogates for PCR primers. These long primers allow a closer annealing to the repeat sequences, thereby reducing the length of the template required for the amplification in fragmented DNA samples, while at the same time rendering amplicons of larger sizes suitable for multiplex assays. We also demonstrate that the annealing of long ssDNA polynucleotides does not need to be fully complementary in the 5’ region of the primers, thus allowing for the design of practically any long primer sequence for developing new multiplex assays. Furthermore, genotyping of intact DNA samples could also benefit from utilizing long primers since their close annealing to the target STR sequences may overcome wrong profiling generated by insertions/deletions present between the STR region and the annealing site of the primers. Additionally, long ssDNA polynucleotides might be utilized in multiplex PCR assays for other types of degraded or fragmented DNA, e.g. circulating, cell-free DNA (ccfDNA). PMID:29099837

  11. Simple extraction method for quantification of phenothiazine residues in pork muscle using liquid chromatography-triple quadrupole tandem mass spectrometry.

    PubMed

    Zhang, Dan; Park, Jin-A; Kim, Seong-Kwan; Cho, Sang-Hyun; Cho, Soo-Min; Shim, Jae-Han; Kim, Jin-Suk; Abd El-Aty, A M; Shin, Ho-Chul

    2017-06-01

    In this study, an analytical method was developed for quantification of residues of the anthelmintic drug phenothiazine (PTZ) in pork muscle using liquid chromatography-tandem mass spectrometry. Muscles were extracted using 0.2% formic acid and 10 mm ammonium formate in acetonitrile, defatted and purified using n-hexane. The drug was well separated on a Waters XBridge™ C 18 analytical column using a binary solvent system consisting of 0.2% formic acid and 10 mm ammonium formate in ultrapure water (A) and acetonitrile (B). Good linearity was achieved over a six-point concentration range in matrix-matched calibration with determination coefficient =0.9846. Fortified pork muscle having concentrations equivalent to and double the limit of quantification (1 ng/g) yielded recovery ranges between 100.82 and 104.03% and relative standard deviations <12%. Samples (n = 5) collected from large markets located in Seoul City tested negative for PTZ residue. In conclusion, 0.2% formic acid and ammonium formate in acetonitrile can effectively extract PTZ from pork muscle without solid-phase extraction, a step normally required for cleanup before analysis and the validated method can be used for routine analysis to ensure the quality of animal products. Copyright © 2016 John Wiley & Sons, Ltd.

  12. A selective and sensitive method for quantitation of lysergic acid diethylamide (LSD) in whole blood by gas chromatography-ion trap tandem mass spectrometry.

    PubMed

    Libong, Danielle; Bouchonnet, Stéphane; Ricordel, Ivan

    2003-01-01

    A gas chromatography-ion trap tandem mass spectrometry (GC-ion trap MS-MS) method for detection and quantitation of LSD in whole blood is presented. The sample preparation process, including a solid-phase extraction step with Bond Elut cartridges, was performed with 2 mL of whole blood. Eight microliters of the purified extract was injected with a cold on-column injection method. Positive chemical ionization was performed using acetonitrile as reagent gas; LSD was detected in the MS-MS mode. The chromatograms obtained from blood extracts showed the great selectivity of the method. GC-MS quantitation was performed using lysergic acid methylpropylamide as the internal standard. The response of the MS was linear for concentrations ranging from 0.02 ng/mL (detection threshold) to 10.0 ng/mL. Several parameters such as the choice of the capillary column, the choice of the internal standard and that of the ionization mode (positive CI vs. EI) were rationalized. Decomposition pathways under both ionization modes were studied. Within-day and between-day stability were evaluated.

  13. A simple and selective method for determination of phthalate biomarkers in vegetable samples by high pressure liquid chromatography-electrospray ionization-tandem mass spectrometry.

    PubMed

    Zhou, Xi; Cui, Kunyan; Zeng, Feng; Li, Shoucong; Zeng, Zunxiang

    2016-06-01

    In the present study, solid-phase extraction cartridges including silica reversed-phase Isolute C18, polymeric reversed-phase Oasis HLB and mixed-mode anion-exchange Oasis MAX, and liquid-liquid extractions with ethyl acetate, n-hexane, dichloromethane and its mixtures were compared for clean-up of phthalate monoesters from vegetable samples. Best recoveries and minimised matrix effects were achieved using ethyl acetate/n-hexane liquid-liquid extraction for these target compounds. A simple and selective method, based on sample preparation by ultrasonic extraction and liquid-liquid extraction clean-up, for the determination of phthalate monoesters in vegetable samples by liquid chromatography/electrospray ionisation-tandem mass spectrometry was developed. The method detection limits for phthalate monoesters ranged from 0.013 to 0.120 ng g(-1). Good linearity (r(2)>0.991) between MQLs and 1000× MQLs was achieved. The intra- and inter-day relative standard deviation values were less than 11.8%. The method was successfully used to determine phthalate monoester metabolites in the vegetable samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. A proteomics method using immunoaffinity fluorogenic derivatization-liquid chromatography/tandem mass spectrometry (FD-LC-MS/MS) to identify a set of interacting proteins.

    PubMed

    Nakata, Katsunori; Saitoh, Ryoichi; Ishigai, Masaki; Imai, Kazuhiro

    2018-02-01

    Biological functions in organisms are usually controlled by a set of interacting proteins, and identifying the proteins that interact is useful for understanding the mechanism of the functions. Immunoprecipitation is a method that utilizes the affinity of an antibody to isolate and identify the proteins that have interacted in a biological sample. In this study, the FD-LC-MS/MS method, which involves fluorogenic derivatization followed by separation and quantification by HPLC and finally identification of proteins by HPLC-tandem mass spectrometry, was used to identify proteins in immunoprecipitated samples, using heat shock protein 90 (HSP90) as a model of an interacting protein in HepaRG cells. As a result, HSC70 protein, which was known to form a complex with HSP90, was isolated, together with three different types of HSP90-beta. The results demonstrated that the proposed immunoaffinity-FD-LC-MS/MS method could be useful for simultaneously detecting and identifying the proteins that interact with a certain protein. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Multi heart-cutting two-dimensional liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry method for the determination of endocrine disrupting compounds in water.

    PubMed

    Matějíček, David

    2012-03-30

    The multi-heart-cutting two-dimensional liquid chromatography-tandem mass spectrometry method using atmospheric pressure photoionization has been developed and successfully validated for the determination of nine endocrine disrupting compounds in river water. The method is based on the use of two different reverse-phase columns connected through a six-port two-position switching valve equipped with a 200 μl loop. An orthogonal separation was achieved by proper selection of stationary phases, mobile phases, and the use of a gradient elution in both dimensions. The method shows excellent performance in terms of accuracy (86.2-111.1%), precision (intra-batch: 6.7-11.2%, inter-batch: 7.2-13.5%), and sensitivity (1.2-7.1 ng l(-1)). Twenty real samples collected from the Loučka and the Svratka rivers were analyzed, the studied compounds were found in all Svratka samples (9.7-11.2 ng l(-1) for β-estradiol, 7.6-9.3 ng l(-1) for estrone, and 24.6-38.7 ng l(-1) for bisphenol A). Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Tandem Repeat Proteins Inspired By Squid Ring Teeth

    NASA Astrophysics Data System (ADS)

    Pena-Francesch, Abdon

    Proteins are large biomolecules consisting of long chains of amino acids that hierarchically assemble into complex structures, and provide a variety of building blocks for biological materials. The repetition of structural building blocks is a natural evolutionary strategy for increasing the complexity and stability of protein structures. However, the relationship between amino acid sequence, structure, and material properties of protein systems remains unclear due to the lack of control over the protein sequence and the intricacies of the assembly process. In order to investigate the repetition of protein building blocks, a recently discovered protein from squids is examined as an ideal protein system. Squid ring teeth are predatory appendages located inside the suction cups that provide a strong grasp of prey, and are solely composed of a group of proteins with tandem repetition of building blocks. The objective of this thesis is the understanding of sequence, structure and property relationship in repetitive protein materials inspired in squid ring teeth for the first time. Specifically, this work focuses on squid-inspired structural proteins with tandem repeat units in their sequence (i.e., repetition of alternating building blocks) that are physically cross-linked via beta-sheet structures. The research work presented here tests the hypothesis that, in these systems, increasing the number of building blocks in the polypeptide chain decreases the protein network defects and improves the material properties. Hence, the sequence, nanostructure, and properties (thermal, mechanical, and conducting) of tandem repeat squid-inspired protein materials are examined. Spectroscopic structural analysis, advanced materials characterization, and entropic elasticity theory are combined to elucidate the structure and material properties of these repetitive proteins. This approach is applied not only to native squid proteins but also to squid-inspired synthetic polypeptides

  17. Better load-weight distribution is needed for tandem-axle logging trucks

    Treesearch

    John E. Baumgras

    1976-01-01

    To determine the GVW and axle weights of tandem-axle logging trucks hauling into two West Virginia sawmills, 543 truckloads of hardwood sawlogs were weighed. The results showed that less than 2 percent of the truckloads exceeded the 48,000 pound GVW limit. While 58 percent of the truckloads exceeded the 32,000 pound tandem-axle weight limit, the front-axle weights...

  18. Flexible and fragmentable tandem photosensitive nanocrystal skins

    NASA Astrophysics Data System (ADS)

    Akhavan, S.; Uran, C.; Bozok, B.; Gungor, K.; Kelestemur, Y.; Lesnyak, V.; Gaponik, N.; Eychmüller, A.; Demir, H. V.

    2016-02-01

    We proposed and demonstrated the first account of large-area, semi-transparent, tandem photosensitive nanocrystal skins (PNSs) constructed on flexible substrates operating on the principle of photogenerated potential buildup, which avoid the need for applying an external bias and circumvent the current-matching limitation between junctions. We successfully fabricated and operated the tandem PNSs composed of single monolayers of colloidal water-soluble CdTe and CdHgTe nanocrystals (NCs) in adjacent junctions on a Kapton polymer tape. Owing to the usage of a single NC layer in each junction, noise generation was significantly reduced while keeping the resulting PNS films considerably transparent. In each junction, photogenerated excitons are dissociated at the interface of the semi-transparent Al electrode and the NC layer, with holes migrating to the contact electrode and electrons trapped in the NCs. As a result, the tandem PNSs lead to an open-circuit photovoltage buildup equal to the sum of those of the two single junctions, exhibiting a total voltage buildup of 128.4 mV at an excitation intensity of 75.8 μW cm-2 at 350 nm. Furthermore, we showed that these flexible PNSs could be bent over 3.5 mm radius of curvature and cut out in arbitrary shapes without damaging the operation of individual parts and without introducing any significant loss in the total sensitivity. These findings indicate that the NC skins are promising as building blocks to make low-cost, flexible, large-area UV/visible sensing platforms with highly efficient full-spectrum conversion.We proposed and demonstrated the first account of large-area, semi-transparent, tandem photosensitive nanocrystal skins (PNSs) constructed on flexible substrates operating on the principle of photogenerated potential buildup, which avoid the need for applying an external bias and circumvent the current-matching limitation between junctions. We successfully fabricated and operated the tandem PNSs composed of

  19. Rapid synthesis of Ti-MCM-41 by microwave-assisted hydrothermal method towards photocatalytic degradation of oxytetracycline.

    PubMed

    Chen, Hanlin; Peng, Yen-Ping; Chen, Ku-Fan; Lai, Chia-Hsiang; Lin, Yung-Chang

    2016-06-01

    This study employed microwave-assisted hydrothermal method to synthesize Ti-MCM-41, which are mesoporous materials with a high surface area and excellent photocatalytic ability. Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), and ultraviolet-visible spectroscopy (UV-Vis) were employed. The XRD findings showed that Ti-MCM-41 exhibited a peak at 2θ of 2.2°, which was attributed to the hexagonal MCM-41 structure. The BET (Brunauer-Emmett-Teller) results agreed with the TEM findings that Ti-MCM-41 has a pore size of about 3-5nm and a high surface area of 883m(2)/g. FTIR results illustrated the existence of Si-O-Si and Si-O-Ti bonds in Ti-MCM-41. The appearance of Ti 2p peaks in the XPS results confirmed the FTIR findings that the Ti was successfully doped into the MCM-41 structure. Zeta (ζ)-potential results indicated that the iso-electric point (IEP) of Ti-MCM-41 was at about pH3.02. In this study, the photocatalytic degradation of oxytetracycline (OTC) at different pH was investigated under Hg lamp irradiation (wavelength 365nm). The rate constant (K'obs) for OTC degradation was 0.012min(-1) at pH3. Furthermore, TOC (total organic carbon) and high resolution LC-MS (liquid chromatography-mass spectrometry) analyses were conducted to elucidate the possible intermediate products and degradation pathway for OTC. The TOC removal efficiency of OTC degradation was 87.0%, 74.4% and 50.9% at pH3, 7 and 10, respectively. LC-MS analysis results showed that the degradation products from OTC resulted from the removal of functional groups from the OTC ring. Copyright © 2016. Published by Elsevier B.V.

  20. A Silicon–Singlet Fission Tandem Solar Cell Exceeding 100% External Quantum Efficiency with High Spectral Stability

    PubMed Central

    2017-01-01

    After 60 years of research, silicon solar cell efficiency saturated close to the theoretical limit, and radically new approaches are needed to further improve the efficiency. The use of tandem systems raises this theoretical power conversion efficiency limit from 34% to 45%. We present the advantageous spectral stability of using voltage-matched tandem solar cells with respect to their traditional series-connected counterparts and experimentally demonstrate how singlet fission can be used to produce simple voltage-matched tandems. Our singlet fission silicon–pentacene tandem solar cell shows efficient photocurrent addition. This allows the tandem system to benefit from carrier multiplication and to produce an external quantum efficiency exceeding 100% at the main absorption peak of pentacene. PMID:28261671

  1. Analysis of glycosaminoglycans in cerebrospinal fluid from patients with mucopolysaccharidoses by isotope-dilution ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Haoyue; Young, Sarah P; Auray-Blais, Christiane; Orchard, Paul J; Tolar, Jakub; Millington, David S

    2011-07-01

    New therapies for the treatment of mucopolysaccharidoses that target the brain, including intrathecal enzyme replacement, are being explored. Quantitative analysis of the glycosaminoglycans (GAGs) that accumulate in these disorders is required to assess the disease burden and monitor the effect of therapy in affected patients. Because current methods lack the required limit of quantification and specificity to analyze GAGs in small volumes of cerebrospinal fluid (CSF), we developed a method based on ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Samples of CSF (25 μL) were evaporated to dryness and subjected to methanolysis. The GAGs were degraded to uronic acid-N-acetylhexosamine dimers and mixed with internal standards derived from deuteriomethanolysis of GAG standards. Specific dimers derived from heparan, dermatan and chondroitin sulfates (HS, DS and CS) were separated by UPLC and analyzed by electrospray ionization MS/MS using selected reaction monitoring for each targeted GAG product and its corresponding internal standard. CSF from control pediatric subjects (n = 22) contained <0.38 mg/L HS, 0.26 mg/L DS, and 2.8 mg/L CS, whereas CSF from patients with Hurler syndrome (n = 7) contained concentrations of DS and HS that were at least 6-fold greater than the upper control limits. These concentrations were reduced by 17.5% to 82.5% after allogeneic transplantation and treatment with intrathecal and intravenous enzyme replacement therapy. The method described here has potential value in monitoring patients with mucopolysaccharidoses receiving treatment targeted to the brain.

  2. Stress degradation studies and development of stability-indicating TLC-densitometry method for determination of prednisolone acetate and chloramphenicol in their individual and combined pharmaceutical formulations

    PubMed Central

    2012-01-01

    A rapid and reproducible stability indicating TLC method was developed for the determination of prednisolone acetate and chloramphenicol in presence of their degraded products. Uniform degradation conditions were maintained by refluxing sixteen reaction mixtures for two hours at 80°C using parallel synthesizer including acidic, alkaline and neutral hydrolysis, oxidation and wet heating degradation. Oxidation at room temperature, photochemical and dry heating degradation studies were also carried out. Separation was done on TLC glass plates, pre-coated with silica gel 60F-254 using chloroform: methanol (14:1 v/v). Spots at Rf 0.21 ± 0.02 and Rf 0.41 ± 0.03 were recognized as chloramphenicol and prednisolone acetate, respectively. Quantitative analysis was done through densitometric measurements at multiwavelength (243 nm, λmax of prednisolone acetate and 278 nm, λmax of chloramphenicol), simultaneously. The developed method was optimized and validated as per ICH guidelines. Method was found linear over the concentration range of 200-6000 ng/spot with the correlation coefficient (r2 ± S.D.) of 0.9976 ± 3.5 and 0.9920 ± 2.5 for prednisolone acetate and chloramphenicol, respectively. The developed TLC method can be applied for routine analysis of prednisolone acetate and chloramphenicol in presence of their degraded products in their individual and combined pharmaceutical formulations. PMID:22264235

  3. Regulation of proteasomal degradation by modulating proteasomal initiation regions

    PubMed Central

    Takahashi, Kazunobu; Matouschek, Andreas; Inobe, Tomonao

    2016-01-01

    Methods for regulating the concentrations of specific cellular proteins are valuable tools for biomedical studies. Artificial regulation of protein degradation by the proteasome is receiving increasing attention. Efficient proteasomal protein degradation requires a degron with two components: a ubiquitin tag that is recognized by the proteasome and a disordered region at which the proteasome engages the substrate and initiates degradation. Here we show that degradation rates can be regulated by modulating the disordered initiation region by the binding of modifier molecules, in vitro and in vivo. These results suggest that artificial modulation of proteasome initiation is a versatile method for conditionally inhibiting the proteasomal degradation of specific proteins. PMID:26278914

  4. Mass spectrometry and tandem mass spectrometry of citrus limonoids.

    PubMed

    Tian, Qingguo; Schwartz, Steven J

    2003-10-15

    Methods for atmospheric pressure chemical ionization tandem mass spectrometry (APCI-MS/MS) of citrus limonoid aglycones and electrospray ionization tandem mass spectrometry (ESI-MS/MS) of limonoid glucosides are reported. The fragmentation patterns of four citrus limonoid aglycones (limonin, nomilin, obacunone, and deacetylnomilin) and six limonoid glucosides, that is, limonin 17-beta-D-glucopyranoside (LG), nomilin 17-beta-D-glucopyranoside (NG), nomilinic acid 17-beta-D-glucopyranoside (NAG), deacetyl nomilinic acid 17-beta-D-glucopyranoside (DNAG), obacunone 17-beta-D-glucopyranoside (OG), and obacunoic acid 17-beta-D-glucopyranoside (OAG) were investigated using a quadruple mass spectrometer in low-energy collisionally activated dissociation (CAD). The four limonoid aglycones and four limonoid glucosides (LG, OG, NAG, and DNAG) were purified from citrus seeds; the other two limonoid glucosides (NG and OAG) were tentatively identified in the crude extract of grapefruit seeds by ESI mass spectrometry in both positive and negative ion analysis. Ammonium hydroxide or acetic acid was added to the mobile phase to facilitate ionization. During positive ion APCI analysis of limonoid aglycones, protonated molecular ion, [M + H]+, or adduct ion, [M + NH3 + H]-, was formed as base peaks when ammonium hydroxide was added to the mobile phase. Molecular anions or adduct ions with acetic acid ([M + HOAc - H] and [M + HOAc]-) or a deprotonated molecular ion were produced during negative ion APCI analysis of limonoid aglycones, depending on the mobile-phase modifier used. Positive ion ESI-MS of limonoid glucosides produced adduct ions of [M + H + NH3]+, [M + Na]+, and [M + K]+ when ammonium hydroxide was added to the mobile phase. After collisionally activated dissociation (CAD) of the limonoid aglycone molecular ions in negative ion APCI analysis, fragment ions indicated structural information of the precursor ions, showing the presence of methyl, carboxyl, and oxygenated ring

  5. Chemotactic selection of pollutant degrading soil bacteria

    DOEpatents

    Hazen, T.C.

    1991-03-04

    A method is described for identifying soil microbial strains which may be bacterial degraders of pollutants. This method includes: Placing a concentration of a pollutant in a substantially closed container; placing the container in a sample of soil for a period of time ranging from one minute to several hours; retrieving the container and collecting its contents; microscopically determining the identity of the bacteria present. Different concentrations of the pollutant can be used to determine which bacteria respond to each concentration. The method can be used for characterizing a polluted site or for looking for naturally occurring biological degraders of the pollutant. Then bacteria identified as degraders of the pollutant and as chemotactically attracted to the pollutant are used to innoculate contaminated soil. To enhance the effect of the bacteria on the pollutant, nutrients are cyclicly provided to the bacteria then withheld to alternately build up the size of the bacterial colony or community and then allow it to degrade the pollutant.

  6. Determination of total and unbound concentrations of lopinavir in plasma using liquid chromatography-tandem mass spectrometry and ultrafiltration methods.

    PubMed

    Illamola, S M; Labat, L; Benaboud, S; Tubiana, R; Warszawski, J; Tréluyer, J M; Hirt, D

    2014-08-15

    Lopinavir is an HIV protease inhibitor with high protein binding (98-99%) in human plasma. This study was designed to develop an ultrafiltration method to measure the unbound concentrations of lopinavir overcoming the non-specific binding issue. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of total concentrations of lopinavir in plasma was developed and validated, and an adaptation was also optimized and validated for the determination of unbound concentrations. The chromatographic separation was performed with a C18 column (100 mm × 2.1mm i.d., 5 μm particle size) using a mobile phase containing deionized water with formic acid, and acetonitrile, with gradient elution at a flow-rate of 350 μL min(-1). Identification of the compounds was performed by multiple reaction monitoring, using electrospray ionization in positive ion mode. The method was validated over a clinical range of 0.01-1 μg/mL for human plasma ultrafiltrate and 0.1-15 μg/mL in human plasma. The inter and intra-assay accuracies and precisions were between 0.23% and 11.37% for total lopinavir concentrations, and between 3.50% and 13.30% for plasma ultrafiltrate (unbound concentration). The ultrafiltration method described allows an accurate separation of the unbound fraction of lopinavir, circumscribing the loss of drug by nonspecific binding (NSB), and the validated LC-MS/MS methodology proposed is suitable for the determination of total and unbound concentrations of lopinavir in clinical practice. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. A tandem mirror plasma source for hybrid plume plasma studies

    NASA Technical Reports Server (NTRS)

    Yang, T. F.; Chang, F. R.; Miller, R. H.; Wenzel, K. W.; Krueger, W. A.

    1985-01-01

    A tandem mirror device to be considered as a hot plasma source for the hybrid plume rocket concept is discussed. The hot plamsa from this device is injected into an exhaust duct, which will interact with an annular hypersonic layer of neutral gas. The device can be used to study the dynamics of the hybrid plume, and to verify the numerical predictions obtained with computer codes. The basic system design is also geared towards low weight and compactness, and high power density at the exhaust. The basic structure of the device consists of four major subsystems: (1) an electric power supply; (2) a low temperature, high density plasma gun, such as a stream gun, an MPD source or gas cell; (3) a power booster in the form of a tandem mirror machine; and (4) an exhaust nozzle arrangement. The configuration of the tandem mirror section is shown.

  8. Validation of a liquid chromatography-electrospray ionization tandem mass spectrometric method to determine six polyether ionophores in raw, UHT, pasteurized and powdered milk.

    PubMed

    Pereira, Mararlene Ulberg; Spisso, Bernardete Ferraz; Jacob, Silvana do Couto; Monteiro, Mychelle Alves; Ferreira, Rosana Gomes; Carlos, Betânia de Souza; da Nóbrega, Armi Wanderley

    2016-04-01

    This study aimed to validate a method developed for the determination of six antibiotics from the polyether ionophore class (lasalocid, maduramicin, monensin, narasin, salinomycin and semduramicin) at residue levels in raw, UHT, pasteurized and powdered milk using QuEChERS extraction and high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS). The validation was conducted under an in-house laboratory protocol that is primarily based on 2002/657/EC Decision, but takes in account the variability of matrix sources. Overall recoveries between 93% and 113% with relative standard deviations up to 16% were obtained under intermediate precision conditions. CCα calculated values did not exceed 20% the Maximum Residue Limit for monensin and 25% the Maximum Levels for all other substances. The method showed to be simple, fast and suitable for verifying the compliance of raw and processed milk samples regarding the limits recommended by Codex Alimentarius and those adopted in European Community for polyether ionophores. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Short-stack modeling of degradation in solid oxide fuel cells. Part I. Contact degradation

    NASA Astrophysics Data System (ADS)

    Gazzarri, J. I.; Kesler, O.

    As the first part of a two paper series, we present a two-dimensional impedance model of a working solid oxide fuel cell (SOFC) to study the effect of contact degradation on the impedance spectrum for the purpose of non-invasive diagnosis. The two dimensional modeled geometry includes the ribbed interconnect, and is adequate to represent co- and counter-flow configurations. Simulated degradation modes include: cathode delamination, interconnect oxidation, and interconnect-cathode detachment. The simulations show differences in the way each degradation mode impacts the impedance spectrum shape, suggesting that identification is possible. In Part II, we present a sensitivity analysis of the results to input parameter variability that reveals strengths and limitations of the method, as well as describing possible interactions between input parameters and concurrent degradation modes.

  10. Progress in Tandem Solar Cells Based on Hybrid Organic-Inorganic Perovskites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Bo; Zheng, Xiaopeng; Bai, Yang

    Owing to their high efficiency, low-cost solution-processability, and tunable bandgap, perovskite solar cells (PSCs) made of hybrid organic-inorganic perovskite (HOIP) thin films are promising top-cell candidates for integration with bottom-cells based on Si or other low-bandgap solar-cell materials to boost the power conversion efficiency (PCE) beyond the Shockley-Quiesser (S-Q) limit. In this review, recent progress in such tandem solar cells based on the emerging PSCs is summarized and reviewed critically. Notable achievements for different tandem solar cell configurations including mechanically-stacked, optical coupling, and monolithically-integrated with PSCs as top-cells are described in detail. Highly-efficient semitransparent PSC top-cells with high transmittance inmore » near-infrared (NIR) region are critical for tandem solar cells. Different types of transparent electrodes with high transmittance and low sheet-resistance for PSCs are reviewed, which presents a grand challenge for PSCs. The strategies to obtain wide-bandgap PSCs with good photo-stability are discussed. In conclusion, the PCE reduction due to reflection loss, parasitic absorption, electrical loss, and current mismatch are analyzed to provide better understanding of the performance of PSC-based tandem solar cells.« less

  11. Progress in Tandem Solar Cells Based on Hybrid Organic-Inorganic Perovskites

    DOE PAGES

    Chen, Bo; Zheng, Xiaopeng; Bai, Yang; ...

    2017-03-06

    Owing to their high efficiency, low-cost solution-processability, and tunable bandgap, perovskite solar cells (PSCs) made of hybrid organic-inorganic perovskite (HOIP) thin films are promising top-cell candidates for integration with bottom-cells based on Si or other low-bandgap solar-cell materials to boost the power conversion efficiency (PCE) beyond the Shockley-Quiesser (S-Q) limit. In this review, recent progress in such tandem solar cells based on the emerging PSCs is summarized and reviewed critically. Notable achievements for different tandem solar cell configurations including mechanically-stacked, optical coupling, and monolithically-integrated with PSCs as top-cells are described in detail. Highly-efficient semitransparent PSC top-cells with high transmittance inmore » near-infrared (NIR) region are critical for tandem solar cells. Different types of transparent electrodes with high transmittance and low sheet-resistance for PSCs are reviewed, which presents a grand challenge for PSCs. The strategies to obtain wide-bandgap PSCs with good photo-stability are discussed. In conclusion, the PCE reduction due to reflection loss, parasitic absorption, electrical loss, and current mismatch are analyzed to provide better understanding of the performance of PSC-based tandem solar cells.« less

  12. Determination of parabens in serum by liquid chromatography-tandem mass spectrometry: Correlation with lipstick use.

    PubMed

    Tahan, Gabriella Padovani; Santos, Nayara de Kássia Souza; Albuquerque, Ana Carolina; Martins, Isarita

    2016-08-01

    Parabens are the most widely used preservative and are considered to be relatively safe compounds. However, studies have demonstrated that they may have estrogenic activity, and there is ongoing debate regarding the safety and potential cancer risk of using products containing these compounds. In the present work, liquid chromatography-tandem mass spectrometry was applied to determine methylparaben and propylparaben concentrations in serum, and the results were correlated with lipstick application. Samples were analyzed using liquid-liquid extraction, followed by liquid chromatography-tandem mass spectrometry. The validation results demonstrated the linearity of the method over a range of 1-20 ng/mL, in addition to the method's precision and accuracy. A statistically significant difference was demonstrated between serum parabens in women who used lipstick containing these substances compared with those not using this cosmetic (p = 0.0005 and 0.0016, respectively), and a strong association was observed between serum parabens and lipstick use (Spearman correlation = 0.7202). Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Simulation of Two Dimensional Electrophoresis and Tandem Mass Spectrometry for Teaching Proteomics

    ERIC Educational Resources Information Center

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul

    2012-01-01

    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations--2D electrophoresis and tandem mass spectrometry.…

  14. An approach for configuring space photovoltaic tandem arrays based on cell layer performance

    NASA Technical Reports Server (NTRS)

    Flora, C. S.; Dillard, P. A.

    1991-01-01

    Meeting solar array performance goals of 300 W/Kg requires use of solar cells with orbital efficiencies greater than 20 percent. Only multijunction cells and cell layers operating in tandem produce this required efficiency. An approach for defining solar array design concepts that use tandem cell layers involve the following: transforming cell layer performance at standard test conditions to on-orbit performance; optimizing circuit configuration with tandem cell layers; evaluating circuit sensitivity to cell current mismatch; developing array electrical design around selected circuit; and predicting array orbital performance including seasonal variations.

  15. Modeling the Performance Limitations and Prospects of Perovskite/Si Tandem Solar Cells under Realistic Operating Conditions

    PubMed Central

    2017-01-01

    Perovskite/Si tandem solar cells have the potential to considerably out-perform conventional solar cells. Under standard test conditions, perovskite/Si tandem solar cells already outperform the Si single junction. Under realistic conditions, however, as we show, tandem solar cells made from current record cells are hardly more efficient than the Si cell alone. We model the performance of realistic perovskite/Si tandem solar cells under real-world climate conditions, by incorporating parasitic cell resistances, nonradiative recombination, and optical losses into the detailed-balance limit. We show quantitatively that when optimizing these parameters in the perovskite top cell, perovskite/Si tandem solar cells could reach efficiencies above 38% under realistic conditions, even while leaving the Si cell untouched. Despite the rapid efficiency increase of perovskite solar cells, our results emphasize the need for further material development, careful device design, and light management strategies, all necessary for highly efficient perovskite/Si tandem solar cells. PMID:28920081

  16. Modeling the Performance Limitations and Prospects of Perovskite/Si Tandem Solar Cells under Realistic Operating Conditions.

    PubMed

    Futscher, Moritz H; Ehrler, Bruno

    2017-09-08

    Perovskite/Si tandem solar cells have the potential to considerably out-perform conventional solar cells. Under standard test conditions, perovskite/Si tandem solar cells already outperform the Si single junction. Under realistic conditions, however, as we show, tandem solar cells made from current record cells are hardly more efficient than the Si cell alone. We model the performance of realistic perovskite/Si tandem solar cells under real-world climate conditions, by incorporating parasitic cell resistances, nonradiative recombination, and optical losses into the detailed-balance limit. We show quantitatively that when optimizing these parameters in the perovskite top cell, perovskite/Si tandem solar cells could reach efficiencies above 38% under realistic conditions, even while leaving the Si cell untouched. Despite the rapid efficiency increase of perovskite solar cells, our results emphasize the need for further material development, careful device design, and light management strategies, all necessary for highly efficient perovskite/Si tandem solar cells.

  17. Monolithic tandem solar cell

    DOEpatents

    Wanlass, M.W.

    1994-06-21

    A single-crystal, monolithic, tandem, photovoltaic solar cell is described which includes (a) an InP substrate having upper and lower surfaces, (b) a first photoactive subcell on the upper surface of the InP substrate, (c) a second photoactive subcell on the first subcell; and (d) an optically transparent prismatic cover layer over the second subcell. The first photoactive subcell is GaInAsP of defined composition. The second subcell is InP. The two subcells are lattice matched. 9 figs.

  18. Monolithic tandem solar cell

    DOEpatents

    Wanlass, Mark W.

    1994-01-01

    A single-crystal, monolithic, tandem, photovoltaic solar cell is described which includes (a) an InP substrate having upper and lower surfaces, (b) a first photoactive subcell on the upper surface of the InP substrate, (c) a second photoactive subcell on the first subcell; and (d) an optically transparent prismatic cover layer over the second subcell. The first photoactive subcell is GaInAsP of defined composition. The second subcell is InP. The two subcells are lattice matched.

  19. Multiclass mycotoxin analysis in edible oils using a simple solvent extraction method and liquid chromatography with tandem mass spectrometry.

    PubMed

    Eom, Taeyong; Cho, Hyun-Deok; Kim, Junghyun; Park, Mihee; An, Jinyoung; Kim, Moosung; Kim, Sheen-Hee; Han, Sang Beom

    2017-11-01

    A simple and rapid method for the simultaneous determination of 11 mycotoxins - aflatoxins B 1 , B 2 , G 1 and G 2 ; fumonisins B 1 , B 2 and B 3 ; ochratoxin A; zearalenone; deoxynivalenol; and T-2 toxin - in edible oils was established using liquid chromatography tandem mass spectrometry (LC-MS/MS). In this study, QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe), QuEChERS with dispersive liquid-liquid microextraction, and solvent extraction were examined for sample preparation. Among these methods, solvent extraction with a mixture of formic acid/acetonitrile (5/95, v/v) successfully extracted all target mycotoxins. Subsequently, a defatting process using n-hexane was employed to remove the fats present in the edible oil samples. Mass spectrometry was carried out using electrospray ionisation in polarity switching mode with multiple reaction monitoring. The developed LC-MS/MS method was validated by assessing the specificity, linearity, recovery, limit of quantification (LOQ), accuracy and precision with reference to Commission Regulation (EC) 401/2006. Mycotoxin recoveries of 51.6-82.8% were achieved in addition to LOQs ranging from 0.025 ng/g to 1 ng/g. The edible oils proved to be relatively uncomplicated matrices and the developed method was applied to 9 edible oil samples, including soybean oil, corn oil and rice bran oil, to evaluate potential mycotoxin contamination. The levels of detection were significantly lower than the international regulatory standards. Therefore, we expect that our developed method, based on simple, two-step sample preparation process, will be suitable for the large-scale screening of mycotoxin contamination in edible oils.

  20. Electromagnetic resonance modes on a two-dimensional tandem grating and its application for broadband absorption in the visible spectrum.

    PubMed

    Han, Sunwoo; Lee, Bong Jae

    2016-01-25

    In this work, we numerically investigate the electromagnetic resonances on two-dimensional tandem grating structures. The base of a tandem grating consists of an opaque Au substrate, a SiO(2) spacer, and a Au grating (concave type); that is, a well-known fishnet structure forming Au/SiO(2)/Au stack. A convex-type Au grating (i.e., topmost grating) is then attached on top of the base fishnet structure with or without additional SiO(2) spacer, resulting in two types of tandem grating structures. In order to calculate the spectral reflectance and local magnetic field distribution, the finite-difference time-domain method is employed. When the topmost Au grating is directly added onto the base fishnet structure, the surface plasmon and magnetic polariton in the base structure are branched out due to the geometric asymmetry with respect to the SiO(2) spacer. If additional SiO(2) spacer is added between the topmost Au grating and the base fishnet structure, new magnetic resonance modes appear due to coupling between two vertically aligned Au/SiO(2)/Au stacks. With the understanding of multiple electromagnetic resonance modes on the proposed tandem grating structures, we successfully design a broadband absorber made of Au and SiO(2) in the visible spectrum.