Sample records for tape-based storage backends

  1. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1991-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed.

  2. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1992-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Flexible optical media offers many benefits in terms of manufacture; for a given capital investment, continuous, web-coating techniques produce more square meters of media than batch coating. The coated layers consist of a backcoat on the non-active side; on the active side there is a subbing layer, then reflector, dye/polymer, and transparent protective overcoat. All these layers have been tailored for ease of manufacture and specific functional characteristics.

  3. ICI optical data storage tape: An archival mass storage media

    NASA Technical Reports Server (NTRS)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  4. DICOM implementation on online tape library storage system

    NASA Astrophysics Data System (ADS)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  5. A new tape product for optical data storage

    NASA Technical Reports Server (NTRS)

    Larsen, T. L.; Woodard, F. E.; Pace, S. J.

    1993-01-01

    A new tape product has been developed for optical data storage. Laser data recording is based on hole or pit formation in a low melting metallic alloy system. The media structure, sputter deposition process, and media characteristics, including write sensitivity, error rates, wear resistance, and archival storage are discussed.

  6. Influence of technology on magnetic tape storage device characteristics

    NASA Technical Reports Server (NTRS)

    Gniewek, John J.; Vogel, Stephen M.

    1994-01-01

    There are available today many data storage devices that serve the diverse application requirements of the consumer, professional entertainment, and computer data processing industries. Storage technologies include semiconductors, several varieties of optical disk, optical tape, magnetic disk, and many varieties of magnetic tape. In some cases, devices are developed with specific characteristics to meet specification requirements. In other cases, an existing storage device is modified and adapted to a different application. For magnetic tape storage devices, examples of the former case are 3480/3490 and QIC device types developed for the high end and low end segments of the data processing industry respectively, VHS, Beta, and 8 mm formats developed for consumer video applications, and D-1, D-2, D-3 formats developed for professional video applications. Examples of modified and adapted devices include 4 mm, 8 mm, 12.7 mm and 19 mm computer data storage devices derived from consumer and professional audio and video applications. With the conversion of the consumer and professional entertainment industries from analog to digital storage and signal processing, there have been increasing references to the 'convergence' of the computer data processing and entertainment industry technologies. There has yet to be seen, however, any evidence of convergence of data storage device types. There are several reasons for this. The diversity of application requirements results in varying degrees of importance for each of the tape storage characteristics.

  7. Moore's law realities for recording systems and memory storage components: HDD, tape, NAND, and optical

    NASA Astrophysics Data System (ADS)

    Fontana, Robert E.; Decad, Gary M.

    2018-05-01

    This paper describes trends in the storage technologies associated with Linear Tape Open (LTO) Tape cartridges, hard disk drives (HDD), and NAND Flash based storage devices including solid-state drives (SSD). This technology discussion centers on the relationship between cost/bit and bit density and, specifically on how the Moore's Law perception that areal density doubling and cost/bit halving every two years is no longer being achieved for storage based components. This observation and a Moore's Law Discussion are demonstrated with data from 9-year storage technology trends, assembled from publically available industry reporting sources.

  8. Performance measurements and operational characteristics of the Storage Tek ACS 4400 tape library with the Cray Y-MP EL

    NASA Technical Reports Server (NTRS)

    Hull, Gary; Ranade, Sanjay

    1993-01-01

    With over 5000 units sold, the Storage Tek Automated Cartridge System (ACS) 4400 tape library is currently the most popular large automated tape library. Based on 3480/90 tape technology, the library is used as the migration device ('nearline' storage) in high-performance mass storage systems. In its maximum configuration, one ACS 4400 tape library houses sixteen 3480/3490 tape drives and is capable of holding approximately 6000 cartridge tapes. The maximum storage capacity of one library using 3480 tapes is 1.2 TB and the advertised aggregate I/O rate is about 24 MB/s. This paper reports on an extensive set of tests designed to accurately assess the performance capabilities and operational characteristics of one STK ACS 4400 tape library holding approximately 5200 cartridge tapes and configured with eight 3480 tape drives. A Cray Y-MP EL2-256 was configured as its host machine. More than 40,000 tape jobs were run in a variety of conditions to gather data in the areas of channel speed characteristics, robotics motion, time taped mounts, and timed tape reads and writes.

  9. Certification of ICI 1012 optical data storage tape

    NASA Technical Reports Server (NTRS)

    Howell, J. M.

    1993-01-01

    ICI has developed a unique and novel method of certifying a Terabyte optical tape. The tape quality is guaranteed as a statistical upper limit on the probability of uncorrectable errors. This is called the Corrected Byte Error Rate or CBER. We developed this probabilistic method because of two reasons why error rate cannot be measured directly. Firstly, written data is indelible, so one cannot employ write/read tests such as used for magnetic tape. Secondly, the anticipated error rates need impractically large samples to measure accurately. For example, a rate of 1E-12 implies only one byte in error per tape. The archivability of ICI 1012 Data Storage Tape in general is well characterized and understood. Nevertheless, customers expect performance guarantees to be supported by test results on individual tapes. In particular, they need assurance that data is retrievable after decades in archive. This paper describes the mathematical basis, measurement apparatus and applicability of the certification method.

  10. Evolving Requirements for Magnetic Tape Data Storage Systems

    NASA Technical Reports Server (NTRS)

    Gniewek, John J.

    1996-01-01

    Magnetic tape data storage systems have evolved in an environment where the major applications have been back-up/restore, disaster recovery, and long term archive. Coincident with the rapidly improving price-performance of disk storage systems, the prime requirements for tape storage systems have remained: (1) low cost per MB, (2) a data rate balanced to the remaining system components. Little emphasis was given to configuring the technology components to optimize retrieval of the stored data. Emerging new applications such as network attached high speed memory (HSM), and digital libraries, place additional emphasis and requirements on the retrieval of the stored data. It is therefore desirable to consider the system to be defined both by STorage And Retrieval System (STARS) requirements. It is possible to provide comparative performance analysis of different STARS by incorporating parameters related to (1) device characteristics, and (2) application characteristics in combination with queuing theory analysis. Results of these analyses are presented here in the form of response time as a function of system configuration for two different types of devices and for a variety of applications.

  11. Flexible storage medium for write-once optical tape

    NASA Technical Reports Server (NTRS)

    Strandjord, Andrew J. G.; Webb, Steven P.; Perettie, Donald J.; Cipriano, Robert A.

    1993-01-01

    A write-once data storage media was developed which is suitable for optical tape applications. The media is manufactured using a continuous film process to deposit a ternary alloy of tin, bismuth, and copper. This laser sensitive layer is sputter deposited onto commercial plastic web as a single-layer thin film. A second layer is sequentially deposited on top of the alloy to enhance the media performance and act as an abrasion resistant hard overcoat. The media was observed to have laser write sensitivities of less than 2.0 njoules/bit, carrier-to-noise levels of greater than 50dB's, modulation depths of approximately 100 percent, read-margins of greater than 35, uniform grain sizes of less than 200 Angstroms, and a media lifetime that exceeds 10 years. Prototype tape media was produced for use in the CREO drive system. The active and overcoat materials are first sputter deposited onto three mil PET film in a single pass through the vacuum coating system, and then converted down into multiple reels of 35mm x 880m tape. One mil PET film was also coated in this manner and then slit and packaged into 3480 tape cartridges.

  12. Evolution of Archival Storage (from Tape to Memory)

    NASA Technical Reports Server (NTRS)

    Ramapriyan, Hampapuram K.

    2015-01-01

    Over the last three decades, there has been a significant evolution in storage technologies supporting archival of remote sensing data. This section provides a brief survey of how these technologies have evolved. Three main technologies are considered - tape, hard disk and solid state disk. Their historical evolution is traced, summarizing how reductions in cost have helped being able to store larger volumes of data on faster media. The cost per GB of media is only one of the considerations in determining the best approach to archival storage. Active archives generally require faster response to user requests for data than permanent archives. The archive costs have to consider facilities and other capital costs, operations costs, software licenses, utilities costs, etc. For meeting requirements in any organization, typically a mix of technologies is needed.

  13. Set processing in a network environment. [data bases and magnetic disks and tapes

    NASA Technical Reports Server (NTRS)

    Hardgrave, W. T.

    1975-01-01

    A combination of a local network, a mass storage system, and an autonomous set processor serving as a data/storage management machine is described. Its characteristics include: content-accessible data bases usable from all connected devices; efficient storage/access of large data bases; simple and direct programming with data manipulation and storage management handled by the set processor; simple data base design and entry from source representation to set processor representation with no predefinition necessary; capability available for user sort/order specification; significant reduction in tape/disk pack storage and mounts; flexible environment that allows upgrading hardware/software configuration without causing major interruptions in service; minimal traffic on data communications network; and improved central memory usage on large processors.

  14. Integration of cloud-based storage in BES III computing environment

    NASA Astrophysics Data System (ADS)

    Wang, L.; Hernandez, F.; Deng, Z.

    2014-06-01

    We present an on-going work that aims to evaluate the suitability of cloud-based storage as a supplement to the Lustre file system for storing experimental data for the BES III physics experiment and as a backend for storing files belonging to individual members of the collaboration. In particular, we discuss our findings regarding the support of cloud-based storage in the software stack of the experiment. We report on our development work that improves the support of CERN' s ROOT data analysis framework and allows efficient remote access to data through several cloud storage protocols. We also present our efforts providing the experiment with efficient command line tools for navigating and interacting with cloud storage-based data repositories both from interactive sessions and grid jobs.

  15. An emerging network storage management standard: Media error monitoring and reporting information (MEMRI) - to determine optical tape data integrity

    NASA Technical Reports Server (NTRS)

    Podio, Fernando; Vollrath, William; Williams, Joel; Kobler, Ben; Crouse, Don

    1998-01-01

    Sophisticated network storage management applications are rapidly evolving to satisfy a market demand for highly reliable data storage systems with large data storage capacities and performance requirements. To preserve a high degree of data integrity, these applications must rely on intelligent data storage devices that can provide reliable indicators of data degradation. Error correction activity generally occurs within storage devices without notification to the host. Early indicators of degradation and media error monitoring 333 and reporting (MEMR) techniques implemented in data storage devices allow network storage management applications to notify system administrators of these events and to take appropriate corrective actions before catastrophic errors occur. Although MEMR techniques have been implemented in data storage devices for many years, until 1996 no MEMR standards existed. In 1996 the American National Standards Institute (ANSI) approved the only known (world-wide) industry standard specifying MEMR techniques to verify stored data on optical disks. This industry standard was developed under the auspices of the Association for Information and Image Management (AIIM). A recently formed AIIM Optical Tape Subcommittee initiated the development of another data integrity standard specifying a set of media error monitoring tools and media error monitoring information (MEMRI) to verify stored data on optical tape media. This paper discusses the need for intelligent storage devices that can provide data integrity metadata, the content of the existing data integrity standard for optical disks, and the content of the MEMRI standard being developed by the AIIM Optical Tape Subcommittee.

  16. Compilation of fatigue, fatigue-crack propagation, and fracture data for 2024 and 7075 aluminum, Ti-6Al-4V titanium, and 300M steel. Volume 1: Description of data and data storage on magnetic tape. Volume 2: Data tape (7-track magnetic tape)

    NASA Technical Reports Server (NTRS)

    Rice, R. C.; Reynolds, J. L.

    1976-01-01

    Fatigue, fatigue-crack-propagation, and fracture data compiled and stored on magnetic tape are documented. Data for 202 and 7075 aluminum alloys, Ti-6Al-4V titanium alloy, and 300M steel are included in the compilation. Approximately 4,500 fatigue, 6,500 fatigue-crack-propagation, and 1,500 fracture data points are stored on magnetic tape. Descriptions of the data, an index to the data on the magnetic tape, information on data storage format on the tape, a listing of all data source references, and abstracts of other pertinent test information from each data source reference are included.

  17. Evaluation of ZFS as an efficient WLCG storage backend

    NASA Astrophysics Data System (ADS)

    Ebert, M.; Washbrook, A.

    2017-10-01

    A ZFS based software raid system was tested for performance against a hardware raid system providing storage based on the traditional Linux file systems XFS and EXT4. These tests were done for a healthy raid array as well as for a degraded raid array and during the rebuild of a raid array. It was found that ZFS performs better in almost all test scenarios. In addition, distinct features of ZFS were tested for WLCG data storage use, like compression and higher raid levels with triple redundancy information. The long term reliability was observed after converting all production storage servers at the Edinburgh WLCG Tier-2 site to ZFS, resulting in about 1.2PB of ZFS based storage at this site.

  18. Efficient Access to Massive Amounts of Tape-Resident Data

    NASA Astrophysics Data System (ADS)

    Yu, David; Lauret, Jérôme

    2017-10-01

    Randomly restoring files from tapes degrades the read performance primarily due to frequent tape mounts. The high latency and time-consuming tape mount and dismount is a major issue when accessing massive amounts of data from tape storage. BNL’s mass storage system currently holds more than 80 PB of data on tapes, managed by HPSS. To restore files from HPSS, we make use of a scheduler software, called ERADAT. This scheduler system was originally based on code from Oak Ridge National Lab, developed in the early 2000s. After some major modifications and enhancements, ERADAT now provides advanced HPSS resource management, priority queuing, resource sharing, web-browser visibility of real-time staging activities and advanced real-time statistics and graphs. ERADAT is also integrated with ACSLS and HPSS for near real-time mount statistics and resource control in HPSS. ERADAT is also the interface between HPSS and other applications such as the locally developed Data Carousel, providing fair resource-sharing policies and related capabilities. ERADAT has demonstrated great performance at BNL.

  19. Tape/head interface study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Existing high energy tapes, high track density heads, and transport guidance techniques were evaluated and characterized to enable these technologies to be employed in future spacecraft recorders with high confidence. The results of these study efforts demonstrated tracking accuracy tape and head density that will support spacecraft recorders with data rates of a minimum of 150 Mbps and storage capacities ranging from 10 to the 10th to 10 to the 11th bits. Seven high energy tapes of either .25 in width, 1.00 in width, or both, were tested. All tapes were tested at the same speed (30 ips) and the same packing density (33 KBI). The performance of all 1 in tapes was considered superior.

  20. Design and implementation of scalable tape archiver

    NASA Technical Reports Server (NTRS)

    Nemoto, Toshihiro; Kitsuregawa, Masaru; Takagi, Mikio

    1996-01-01

    In order to reduce costs, computer manufacturers try to use commodity parts as much as possible. Mainframes using proprietary processors are being replaced by high performance RISC microprocessor-based workstations, which are further being replaced by the commodity microprocessor used in personal computers. Highly reliable disks for mainframes are also being replaced by disk arrays, which are complexes of disk drives. In this paper we try to clarify the feasibility of a large scale tertiary storage system composed of 8-mm tape archivers utilizing robotics. In the near future, the 8-mm tape archiver will be widely used and become a commodity part, since recent rapid growth of multimedia applications requires much larger storage than disk drives can provide. We designed a scalable tape archiver which connects as many 8-mm tape archivers (element archivers) as possible. In the scalable archiver, robotics can exchange a cassette tape between two adjacent element archivers mechanically. Thus, we can build a large scalable archiver inexpensively. In addition, a sophisticated migration mechanism distributes frequently accessed tapes (hot tapes) evenly among all of the element archivers, which improves the throughput considerably. Even with the failures of some tape drives, the system dynamically redistributes hot tapes to the other element archivers which have live tape drives. Several kinds of specially tailored huge archivers are on the market, however, the 8-mm tape scalable archiver could replace them. To maintain high performance in spite of high access locality when a large number of archivers are attached to the scalable archiver, it is necessary to scatter frequently accessed cassettes among the element archivers and to use the tape drives efficiently. For this purpose, we introduce two cassette migration algorithms, foreground migration and background migration. Background migration transfers cassettes between element archivers to redistribute frequently accessed

  1. A case for automated tape in clinical imaging.

    PubMed

    Bookman, G; Baune, D

    1998-08-01

    Electronic archiving of radiology images over many years will require many terabytes of storage with a need for rapid retrieval of these images. As more large PACS installations are installed and implemented, a data crisis occurs. The ability to store this large amount of data using the traditional method of optical jukeboxes or online disk alone becomes an unworkable solution. The amount of floor space number of optical jukeboxes, and off-line shelf storage required to store the images becomes unmanageable. With the recent advances in tape and tape drives, the use of tape for long term storage of PACS data has become the preferred alternative. A PACS system consisting of a centrally managed system of RAID disk, software and at the heart of the system, tape, presents a solution that for the first time solves the problems of multi-modality high end PACS, non-DICOM image, electronic medical record and ADT data storage. This paper will examine the installation of the University of Utah, Department of Radiology PACS system and the integration of automated tape archive. The tape archive is also capable of storing data other than traditional PACS data. The implementation of an automated data archive to serve the many other needs of a large hospital will also be discussed. This will include the integration of a filmless cardiology department and the backup/archival needs of a traditional MIS department. The need for high bandwidth to tape with a large RAID cache will be examined and how with an interface to a RIS pre-fetch engine, tape can be a superior solution to optical platters or other archival solutions. The data management software will be discussed in detail. The performance and cost of RAID disk cache and automated tape compared to a solution that includes optical will be examined.

  2. Tape SCSI monitoring and encryption at CERN

    NASA Astrophysics Data System (ADS)

    Laskaridis, Stefanos; Bahyl, V.; Cano, E.; Leduc, J.; Murray, S.; Cancio, G.; Kruse, D.

    2017-10-01

    CERN currently manages the largest data archive in the HEP domain; over 180PB of custodial data is archived across 7 enterprise tape libraries containing more than 25,000 tapes and using over 100 tape drives. Archival storage at this scale requires a leading edge monitoring infrastructure that acquires live and lifelong metrics from the hardware in order to assess and proactively identify potential drive and media level issues. In addition, protecting the privacy of sensitive archival data is becoming increasingly important and with it the need for a scalable, compute-efficient and cost-effective solution for data encryption. In this paper, we first describe the implementation of acquiring tape medium and drive related metrics reported by the SCSI interface and its integration with our monitoring system. We then address the incorporation of tape drive real-time encryption with dedicated drive hardware into the CASTOR [1] hierarchical mass storage system.

  3. Digital optical tape: Technology and standardization issues

    NASA Technical Reports Server (NTRS)

    Podio, Fernando L.

    1996-01-01

    During the coming years, digital data storage technologies will continue an aggressive growth to satisfy the user's need for higher storage capacities, higher data transfer rates and long-term archival media properties. Digital optical tape is a promising technology to satisfy these user's needs. As any emerging data storage technology, the industry faces many technological and standardization challenges. The technological challenges are great, but feasible to overcome. Although it is too early to consider formal industry standards, the optical tape industry has decided to work together by initiating prestandardization efforts that may lead in the future to formal voluntary industry standards. This paper will discuss current industry optical tape drive developments and the types of standards that will be required for the technology. The status of current industry prestandardization efforts will also be discussed.

  4. Transaction aware tape-infrastructure monitoring

    NASA Astrophysics Data System (ADS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-06-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  5. An efficient, modular and simple tape archiving solution for LHC Run-3

    NASA Astrophysics Data System (ADS)

    Murray, S.; Bahyl, V.; Cancio, G.; Cano, E.; Kotlyar, V.; Kruse, D. F.; Leduc, J.

    2017-10-01

    The IT Storage group at CERN develops the software responsible for archiving to tape the custodial copy of the physics data generated by the LHC experiments. Physics run 3 will start in 2021 and will introduce two major challenges for which the tape archive software must be evolved. Firstly the software will need to make more efficient use of tape drives in order to sustain the predicted data rate of 150 petabytes per year as opposed to the current 50 petabytes per year. Secondly the software will need to be seamlessly integrated with EOS, which has become the de facto disk storage system provided by the IT Storage group for physics data. The tape storage software for LHC physics run 3 is code named CTA (the CERN Tape Archive). This paper describes how CTA will introduce a pre-emptive drive scheduler to use tape drives more efficiently, will encapsulate all tape software into a single module that will sit behind one or more EOS systems, and will be simpler by dropping support for obsolete backwards compatibility.

  6. Mysql Data-Base Applications for Dst-Like Physics Analysis

    NASA Astrophysics Data System (ADS)

    Tsenov, Roumen

    2004-07-01

    The data and analysis model developed and being used in the HARP experiment for studying hadron production at CERN Proton Synchrotron is discussed. Emphasis is put on usage of data-base (DB) back-ends for persistent storing and retrieving "alive" C++ objects encapsulating raw and reconstructed data. Concepts of "Data Summary Tape" (DST) as a logical collection of DB-persistent data of different types, and of "intermediate DST" (iDST) as a physical "tag" of DST, are introduced. iDST level of persistency allows a powerful, DST-level of analysis to be performed by applications running on an isolated machine (even laptop) with no connection to the experiment's main data storage. Implementation of these concepts is considered.

  7. Digital Linear Tape (DLT) technology and product family overview

    NASA Technical Reports Server (NTRS)

    Lignos, Demetrios

    1994-01-01

    The demand that began a couple of years ago for increased data storage capacity continues. Peripheral Strategies (a Santa Barbara, California, Storage Market Research Firm) projects the amount of data stored on the average enterprise network will grow by 50 percent to 100 percent per year. Furthermore, Peripheral Strategies says that a typical mid-range workstation system containing 30GB to 50GB of storage today will grow at the rate of 50 percent per year. Dan Friedlander, a Boulder, Colorado-based consultant specializing in PC-LAN backup, says, 'The average NetWare LAN is about 8GB, but there are many that have 30GB to 300GB.....' The substantial growth of storage requirements has created various tape technologies that seek to satisfy the needs of today's and, especially, the next generations's systems and applications. There are five leading tape technologies in the market today: QIC (Quarter Inch Cartridge), IBM 3480/90, 8mm, DAT (Digital Audio Tape) and DLT (Digital Linear Tape). Product performance specifications and user needs have combined to classify these technologies into low-end, mid-range, and high-end systems applications. Although the manufacturers may try to position their products differently, product specifications and market requirements have determined that QIC and DAT are primarily low-end systems products while 8mm and DLT are competing for mid-range systems applications and the high-end systems space, where IBM compatibility is not required. The 3480/90 products seem to be used primarily in the IBM market, for interchangeability purposes. There are advantages and disadvantages for each of the tape technologies in the market today. We believe that DLT technology offers a significant number of very important features and specifications that make it extremely attractive for most current as well as emerging new applications, such as Hierarchical Storage Management (HSM). This paper will demonstrate why we think that the DLT technology and family

  8. Magnetic tape

    NASA Technical Reports Server (NTRS)

    Robinson, Harriss

    1992-01-01

    The move to visualization and image processing in data systems is increasing the demand for larger and faster mass storage systems. The technology of choice is magnetic tape. This paper briefly reviews the technology past, present, and projected. A case is made for standards and the value of the standards to users.

  9. Storage, Preservation, and Recovery of Magnetic Recording Tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, Edward F.

    1994-01-01

    During the 1970's, a commercial magnetic recording tape fabricated with magnetic oxide particles, and with oxide and backcoat binders made from polyester urethane was being used for spacecraft tape recorders, and which would periodically manifest operational problems such as layer-to-layer adhesion, stick-slip, and shedding of sticky organic materials. These problems were generally associated with periods of high humidity. An experimental study identified that these problems resulted from hydrolysis of the polyester urethane binders.

  10. Ceph-based storage services for Run2 and beyond

    NASA Astrophysics Data System (ADS)

    van der Ster, Daniel C.; Lamanna, Massimo; Mascetti, Luca; Peters, Andreas J.; Rousseau, Hervé

    2015-12-01

    In 2013, CERN IT evaluated then deployed a petabyte-scale Ceph cluster to support OpenStack use-cases in production. With now more than a year of smooth operations, we will present our experience and tuning best-practices. Beyond the cloud storage use-cases, we have been exploring Ceph-based services to satisfy the growing storage requirements during and after Run2. First, we have developed a Ceph back-end for CASTOR, allowing this service to deploy thin disk server nodes which act as gateways to Ceph; this feature marries the strong data archival and cataloging features of CASTOR with the resilient and high performance Ceph subsystem for disk. Second, we have developed RADOSFS, a lightweight storage API which builds a POSIX-like filesystem on top of the Ceph object layer. When combined with Xrootd, RADOSFS can offer a scalable object interface compatible with our HEP data processing applications. Lastly the same object layer is being used to build a scalable and inexpensive NFS service for several user communities.

  11. Striped tertiary storage arrays

    NASA Technical Reports Server (NTRS)

    Drapeau, Ann L.

    1993-01-01

    Data stripping is a technique for increasing the throughput and reducing the response time of large access to a storage system. In striped magnetic or optical disk arrays, a single file is striped or interleaved across several disks; in a striped tape system, files are interleaved across tape cartridges. Because a striped file can be accessed by several disk drives or tape recorders in parallel, the sustained bandwidth to the file is greater than in non-striped systems, where access to the file are restricted to a single device. It is argued that applying striping to tertiary storage systems will provide needed performance and reliability benefits. The performance benefits of striping for applications using large tertiary storage systems is discussed. It will introduce commonly available tape drives and libraries, and discuss their performance limitations, especially focusing on the long latency of tape accesses. This section will also describe an event-driven tertiary storage array simulator that is being used to understand the best ways of configuring these storage arrays. The reliability problems of magnetic tape devices are discussed, and plans for modeling the overall reliability of striped tertiary storage arrays to identify the amount of error correction required are described. Finally, work being done by other members of the Sequoia group to address latency of accesses, optimizing tertiary storage arrays that perform mostly writes, and compression is discussed.

  12. Recording and wear characteristics of 4 and 8 mm helical scan tapes

    NASA Technical Reports Server (NTRS)

    Peter, Klaus J.; Speliotis, Dennis E.

    1993-01-01

    Performance data of media on helical scan tape systems (4 and 8 mm) is presented and various types of media are compared. All measurements were performed on a standard MediaLogic model ML4500 Tape Evaluator System with a Flash Converter option for time based measurements. The 8 mm tapes are tested on an Exabyte 8200 drive and 4 mm tapes on an Archive Python drive; in both cases, the head transformer is directly connected to a Media Logic Read/Write circuit and test electronics. The drive functions only as a tape transport and its data recover circuits are not used. Signal to Noise, PW 50, Peak Shift and Wear Test data is used to compare the performance of MP (metal particle), BaFe, and metal evaporate (ME). ME tape is the clear winner in magnetic performance but its susceptibility to wear and corrosion, make it less than ideal for data storage.

  13. Design and Implementation of A Backend Multiple-Processor Relational Data Base Computer System.

    DTIC Science & Technology

    1981-12-01

    propogated to other parts of the data base. 18 Cost. As mentioned earlier, a primary motivation for the backend DBMS work is the development of an...uniquely identify the n- tuples of the relation is called the primary key. For example, in Figure 3, the primary key is NUMBER. A primary key is said to...identifying the tuple. For example, in Figure 3, (NUMBER,TITLE) would not be a nonredundant primary key for COURSE. A relation can contain more than one

  14. Experience in running relational databases on clustered storage

    NASA Astrophysics Data System (ADS)

    Gaspar Aparicio, Ruben; Potocky, Miroslav

    2015-12-01

    For past eight years, CERN IT Database group has based its backend storage on NAS (Network-Attached Storage) architecture, providing database access via NFS (Network File System) protocol. In last two and half years, our storage has evolved from a scale-up architecture to a scale-out one. This paper describes our setup and a set of functionalities providing key features to other services like Database on Demand [1] or CERN Oracle backup and recovery service. It also outlines possible trend of evolution that, storage for databases could follow.

  15. Implementation of system intelligence in a 3-tier telemedicine/PACS hierarchical storage management system

    NASA Astrophysics Data System (ADS)

    Chao, Woodrew; Ho, Bruce K. T.; Chao, John T.; Sadri, Reza M.; Huang, Lu J.; Taira, Ricky K.

    1995-05-01

    Our tele-medicine/PACS archive system is based on a three-tier distributed hierarchical architecture, including magnetic disk farms, optical jukebox, and tape jukebox sub-systems. The hierarchical storage management (HSM) architecture, built around a low cost high performance platform [personal computers (PC) and Microsoft Windows NT], presents a very scaleable and distributed solution ideal for meeting the needs of client/server environments such as tele-medicine, tele-radiology, and PACS. These image based systems typically require storage capacities mirroring those of film based technology (multi-terabyte with 10+ years storage) and patient data retrieval times at near on-line performance as demanded by radiologists. With the scaleable architecture, storage requirements can be easily configured to meet the needs of the small clinic (multi-gigabyte) to those of a major hospital (multi-terabyte). The patient data retrieval performance requirement was achieved by employing system intelligence to manage migration and caching of archived data. Relevant information from HIS/RIS triggers prefetching of data whenever possible based on simple rules. System intelligence embedded in the migration manger allows the clustering of patient data onto a single tape during data migration from optical to tape medium. Clustering of patient data on the same tape eliminates multiple tape loading and associated seek time during patient data retrieval. Optimal tape performance can then be achieved by utilizing the tape drives high performance data streaming capabilities thereby reducing typical data retrieval delays associated with streaming tape devices.

  16. Performance Modeling of Network-Attached Storage Device Based Hierarchical Mass Storage Systems

    NASA Technical Reports Server (NTRS)

    Menasce, Daniel A.; Pentakalos, Odysseas I.

    1995-01-01

    Network attached storage devices improve I/O performance by separating control and data paths and eliminating host intervention during the data transfer phase. Devices are attached to both a high speed network for data transfer and to a slower network for control messages. Hierarchical mass storage systems use disks to cache the most recently used files and a combination of robotic and manually mounted tapes to store the bulk of the files in the file system. This paper shows how queuing network models can be used to assess the performance of hierarchical mass storage systems that use network attached storage devices as opposed to host attached storage devices. Simulation was used to validate the model. The analytic model presented here can be used, among other things, to evaluate the protocols involved in 1/0 over network attached devices.

  17. Design optimization of superconducting coils based on asymmetrical characteristics of REBCO tapes

    NASA Astrophysics Data System (ADS)

    Hong, Zhiyong; Li, Wenrong; Chen, Yanjun; Gömöry, Fedor; Frolek, Lubomír; Zhang, Min; Sheng, Jie

    2018-07-01

    Angle dependence Ic(B,θ) of superconducting tape is a crucial parameter to calculate the influence of magnetic field during the design of superconducting applications,. This paper focuses on the asymmetrical characteristics found in REBCO tapes and further applications based on this phenomenon. This paper starts with angle dependence measurements of different HTS tapes, asymmetrical characteristics are found in some of the testing samples. On basis of this property, optimization of superconducting coils in superconducting motor, transformer and insert magnet is discussed by simulation. Simplified experiments which represent the structure of insert magnet were carried out to prove the validity of numerical studies. Conclusions obtained in this paper show that the asymmetrical property of superconducting tape is quite important in design of superconducting applications, and optimized winding technique based on this property can be used to improve the performance of superconducting devices.

  18. Back-end of the fuel cycle - Indian scenario

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wattal, P.K.

    Nuclear power has a key role in meeting the energy demands of India. This can be sustained by ensuring robust technology for the back end of the fuel cycle. Considering the modest indigenous resources of U and a huge Th reserve, India has adopted a three stage Nuclear Power Programme (NPP) based on 'closed fuel cycle' approach. This option on 'Recovery and Recycle' serves twin objectives of ensuring adequate supply of nuclear fuel and also reducing the long term radio-toxicity of the wastes. Reprocessing of the spent fuel by Purex process is currently employed. High Level Liquid Waste (HLW) generatedmore » during reprocessing is vitrified and undergoes interim storage. Back-end technologies are constantly modified to address waste volume minimization and radio-toxicity reduction. Long-term management of HLW in Indian context would involve partitioning of long lived minor actinides and recovery of valuable fission products specifically cesium. Recovery of minor actinides from HLW and its recycle is highly desirable for the sustained growth of India's NPPs. In this context, programme for developing and deploying partitioning technologies on industrial scale is pursued. The partitioned elements could be either transmuted in Fast Reactors (FRs)/Accelerated Driven Systems (ADS) as an integral part of sustainable Indian NPP. (authors)« less

  19. The Carbon Monoxide Tape Recorder

    NASA Technical Reports Server (NTRS)

    Schoeberl, M. R.; Duncan, B. N.; Douglass, A. R.; Waters, J.; Livesey, N.; Read, W.; Filipiak, M.

    2006-01-01

    Using Aura MLS data we have identified the stratospheric tape recorder in carbon monoxide (CO). Unlike the water vapor tape recorder, which is controlled by upper troposphere processes, the CO tape recorder is linked to seasonal biomass burning. Since CO has a lifetime of only a few months, the CO tape recorder barely extends above 20 km. The tape head for CO appears to be close to 360K near the same location as the water vapor tape head [Read et al, 20041. Both tape heads are below the equatorial cold point tropopause but above the base of the tropical tropopause layer. The tape recorder signal becomes more distinct from 360K to 380K suggesting that convective detrainment of plays a decreasingly important role with altitude. The Global Modeling Initiative chemical transport model forced by the climatology of biomass burning reproduces the CO tape recorder.

  20. High Density Digital Data Storage System

    NASA Technical Reports Server (NTRS)

    Wright, Kenneth D., II; Gray, David L.; Rowland, Wayne D.

    1991-01-01

    The High Density Digital Data Storage System was designed to provide a cost effective means for storing real-time data from the field-deployable digital acoustic measurement system. However, the high density data storage system is a standalone system that could provide a storage solution for many other real time data acquisition applications. The storage system has inputs for up to 20 channels of 16-bit digital data. The high density tape recorders presently being used in the storage system are capable of storing over 5 gigabytes of data at overall transfer rates of 500 kilobytes per second. However, through the use of data compression techniques the system storage capacity and transfer rate can be doubled. Two tape recorders have been incorporated into the storage system to produce a backup tape of data in real-time. An analog output is provided for each data channel as a means of monitoring the data as it is being recorded.

  1. The Challenges Facing Science Data Archiving on Current Mass Storage Systems

    NASA Technical Reports Server (NTRS)

    Peavey, Bernard; Behnke, Jeanne (Editor)

    1996-01-01

    This paper discusses the desired characteristics of a tape-based petabyte science data archive and retrieval system required to store and distribute several terabytes (TB) of data per day over an extended period of time, probably more than 115 years, in support of programs such as the Earth Observing System Data and Information System (EOSDIS). These characteristics take into consideration not only cost effective and affordable storage capacity, but also rapid access to selected files, and reading rates that are needed to satisfy thousands of retrieval transactions per day. It seems that where rapid random access to files is not crucial, the tape medium, magnetic or optical, continues to offer cost effective data storage and retrieval solutions, and is likely to do so for many years to come. However, in environments like EOS these tape based archive solutions provide less than full user satisfaction. Therefore, the objective of this paper is to describe the performance and operational enhancements that need to be made to the current tape based archival systems in order to achieve greater acceptance by the EOS and similar user communities.

  2. Volume server: A scalable high speed and high capacity magnetic tape archive architecture with concurrent multi-host access

    NASA Technical Reports Server (NTRS)

    Rybczynski, Fred

    1993-01-01

    A major challenge facing data processing centers today is data management. This includes the storage of large volumes of data and access to it. Current media storage for large data volumes is typically off line and frequently off site in warehouses. Access to data archived in this fashion can be subject to long delays, errors in media selection and retrieval, and even loss of data through misplacement or damage to the media. Similarly, designers responsible for architecting systems capable of continuous high-speed recording of large volumes of digital data are faced with the challenge of identifying technologies and configurations that meet their requirements. Past approaches have tended to evaluate the combination of the fastest tape recorders with the highest capacity tape media and then to compromise technology selection as a consequence of cost. This paper discusses an architecture that addresses both of these challenges and proposes a cost effective solution based on robots, high speed helical scan tape drives, and large-capacity media.

  3. Digital Audio Tape: Yet Another Archival Media?

    ERIC Educational Resources Information Center

    Vanker, Anthony D.

    1989-01-01

    Provides an introduction to the technical aspects of digital audiotape and compares it to other computer storage devices such as optical data disks and magnetic tape cartridges in terms of capacity, transfer rate, and cost. The current development of digital audiotape standards is also discussed. (five references) (CLB)

  4. Feasibility model of a high reliability five-year tape transport, volume 2

    NASA Technical Reports Server (NTRS)

    Eshleman, R. L.; Meyers, A. P.; Davidson, W. A.; Gortowski, R. C.; Anderson, M. E.

    1973-01-01

    Analysis of the design features of the modularized tape transport renders a life expectancy in excess of five years. Tests performed on the tape transport were directed toward determining its performance capability. These tests revealed that the tape jitter and skew are in the range achieved by high quality digital tape transports. Guidance of the tape in the lateral sense by the use of the two hybrid crowned rollers proved to be excellent. Tracking was maintained within less than one thousandth inch (approximately 2 micrometers). The guidance capability demonstrated makes possible the achievement of the performance objective of 7.2 x 10 to the 9th power storage capability employing 1500 ft. of one inch wide tape with a packing density of 5,000 bits per inch per track on 80 tracks. Also, the machine showed excellent characteristics operating over a wide range of tape speeds. The basic design concept lends itself to growth and adaptation to a wide range of recorder requirements.

  5. Chemistry of cometary meteoroids from video-tape records of meteor spectra

    NASA Technical Reports Server (NTRS)

    Millman, P. M.

    1982-01-01

    The chemistry of the cometary meteoroids was studied by closed circuit television observing systems. Vidicon cameras produce basic data on standard video tape and enable the recording of the spectra of faint shower meteors, consequently the chemical study is extended to smaller particles and we have a larger data bank than is available from the more conventional method of recording meteor spectra by photography. The two main problems in using video tape meteor spectrum records are: (1) the video tape recording has a much lower resolution than the photographic technique; (2) video tape is relatively new type of data storage in astronomy and the methods of quantitative photometry have not yet been fully developed in the various fields where video tape is used. The use of the most detailed photographic meteor spectra to calibrate the video tape records and to make positive identification of the more prominent chemical elements appearing in the spectra may solve the low resolution problem. Progress in the development of standard photometric techniques for the analysis of video tape records of meteor spectra is reported.

  6. Disk storage management for LHCb based on Data Popularity estimator

    NASA Astrophysics Data System (ADS)

    Hushchyn, Mikhail; Charpentier, Philippe; Ustyuzhanin, Andrey

    2015-12-01

    This paper presents an algorithm providing recommendations for optimizing the LHCb data storage. The LHCb data storage system is a hybrid system. All datasets are kept as archives on magnetic tapes. The most popular datasets are kept on disks. The algorithm takes the dataset usage history and metadata (size, type, configuration etc.) to generate a recommendation report. This article presents how we use machine learning algorithms to predict future data popularity. Using these predictions it is possible to estimate which datasets should be removed from disk. We use regression algorithms and time series analysis to find the optimal number of replicas for datasets that are kept on disk. Based on the data popularity and the number of replicas optimization, the algorithm minimizes a loss function to find the optimal data distribution. The loss function represents all requirements for data distribution in the data storage system. We demonstrate how our algorithm helps to save disk space and to reduce waiting times for jobs using this data.

  7. Laser-plasma interactions from thin tapes for high-energy electron accelerators and seeding compact FELs

    NASA Astrophysics Data System (ADS)

    Shaw, Brian Henry

    This thesis comprises a detailed investigation of the physics of using a plasma mirror (PM) from a tape by reflecting ultrashort pulses from a laser-triggered surface plasma. The tapes used in the characterization of the PM are VHS and computer data storage tape. The tapes are 6.6 m (computer storage tape) and 15 m (VHS) thick. Each tape is 0.5 inches wide, and 10s of meters of tape are spooled using a tape drive; providing thousands of shots on a single reel of tape. The amount of reflected energy of the PM was studied for different input intensities. The fluence was varied by translating the focus of the laser upstream and downstream of the tape, which changed the spot size on the tape surface and hence changed the fluence. This study measured reflectances from both sides of the two tapes, and for input light of both s and p-polarizations. Lastly, an analytic model was developed to understand the reflectance as a function of fluence for each tape material and polarization. Another application that benefits from the advancements of LPA technology is an LPAbased FEL. By sending a high quality electron bunch through an undulator (a periodic structure of positive and negative magnetic poles), the electrons oscillate transversely to the propagation axis and produce radiation. The 1.5 m THUNDER undulator at the BELLA Center has been commissioned using electron beams of 400MeV beams with broad energy spread (35%). To produce a coherent LPA-based FEL, the beam quality would need to improve to sub-percent level energy spread. A seed source could be used to help induce bunching of the electron beam within the undulator. This thesis described the experimental investigation of the physics of using solid-based surface high-harmonic generation (SHHG) from a thin tape as a possible seed source for an FEL. A thin tape placed within centimeters of the undulator's entrance could act as a harmonic generating source, while simultaneously transmitting an electron beam. This removes

  8. Software for Improved Extraction of Data From Tape Storage

    NASA Technical Reports Server (NTRS)

    Cheng, Chiu-Fu

    2003-01-01

    A computer program has been written to replace the original software of Racal Storeplex Delta tape recorders, which are used at Stennis Space Center. The original software could be activated by a command- line interface only; the present software offers the option of a command-line or graphical user interface. The present software also offers the option of batch-file operation (activation by a file that contains command lines for operations performed consecutively). The present software is also more reliable than was the original software: The original software was plagued by several deficiencies that made it difficult to execute, modify, and test. In addition, when using the original software to extract data that had been recorded within specified intervals of time, the resolution with which one could control starting and stopping times was no finer than about a second (or, in some cases, several seconds). In contrast, the present software is capable of controlling playback times to within 1/100 second of times specified by the user, assuming that the tape-recorder clock is accurate to within 1/100 second.

  9. Emerging Network Storage Management Standards for Intelligent Data Storage Subsystems

    NASA Technical Reports Server (NTRS)

    Podio, Fernando; Vollrath, William; Williams, Joel; Kobler, Ben; Crouse, Don

    1998-01-01

    This paper discusses the need for intelligent storage devices and subsystems that can provide data integrity metadata, the content of the existing data integrity standard for optical disks and techniques and metadata to verify stored data on optical tapes developed by the Association for Information and Image Management (AIIM) Optical Tape Committee.

  10. Online mass storage system detailed requirements document

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The requirements for an online high density magnetic tape data storage system that can be implemented in a multipurpose, multihost environment is set forth. The objective of the mass storage system is to provide a facility for the compact storage of large quantities of data and to make this data accessible to computer systems with minimum operator handling. The results of a market survey and analysis of candidate vendor who presently market high density tape data storage systems are included.

  11. dCache on Steroids - Delegated Storage Solutions

    DOE PAGES

    Mkrtchyan, Tigran; Adeyemi, F.; Ashish, A.; ...

    2017-11-23

    For over a decade, dCache.org has delivered a robust software used at more than 80 Universities and research institutes around the world, allowing these sites to provide reliable storage services for the WLCG experiments as well as many other scientific communities. The flexible architecture of dCache allows running it in a wide variety of configurations and platforms - from a SoC based all-in-one Raspberry-Pi up to hundreds of nodes in a multipetabyte installation. Due to lack of managed storage at the time, dCache implemented data placement, replication and data integrity directly. Today, many alternatives are available: S3, GlusterFS, CEPH andmore » others. While such solutions position themselves as scalable storage systems, they cannot be used by many scientific communities out of the box. The absence of community-accepted authentication and authorization mechanisms, the use of product specific protocols and the lack of namespace are some of the reasons that prevent wide-scale adoption of these alternatives. Most of these limitations are already solved by dCache. By delegating low-level storage management functionality to the above-mentioned new systems and providing the missing layer through dCache, we provide a solution which combines the benefits of both worlds - industry standard storage building blocks with the access protocols and authentication required by scientific communities. In this paper, we focus on CEPH, a popular software for clustered storage that supports file, block and object interfaces. CEPH is often used in modern computing centers, for example as a backend to OpenStack services. We will show prototypes of dCache running with a CEPH backend and discuss the benefits and limitations of such an approach. As a result, we will also outline the roadmap for supporting ‘delegated storage’ within the dCache releases.« less

  12. dCache on Steroids - Delegated Storage Solutions

    NASA Astrophysics Data System (ADS)

    Mkrtchyan, T.; Adeyemi, F.; Ashish, A.; Behrmann, G.; Fuhrmann, P.; Litvintsev, D.; Millar, P.; Rossi, A.; Sahakyan, M.; Starek, J.

    2017-10-01

    For over a decade, dCache.org has delivered a robust software used at more than 80 Universities and research institutes around the world, allowing these sites to provide reliable storage services for the WLCG experiments as well as many other scientific communities. The flexible architecture of dCache allows running it in a wide variety of configurations and platforms - from a SoC based all-in-one Raspberry-Pi up to hundreds of nodes in a multipetabyte installation. Due to lack of managed storage at the time, dCache implemented data placement, replication and data integrity directly. Today, many alternatives are available: S3, GlusterFS, CEPH and others. While such solutions position themselves as scalable storage systems, they cannot be used by many scientific communities out of the box. The absence of community-accepted authentication and authorization mechanisms, the use of product specific protocols and the lack of namespace are some of the reasons that prevent wide-scale adoption of these alternatives. Most of these limitations are already solved by dCache. By delegating low-level storage management functionality to the above-mentioned new systems and providing the missing layer through dCache, we provide a solution which combines the benefits of both worlds - industry standard storage building blocks with the access protocols and authentication required by scientific communities. In this paper, we focus on CEPH, a popular software for clustered storage that supports file, block and object interfaces. CEPH is often used in modern computing centers, for example as a backend to OpenStack services. We will show prototypes of dCache running with a CEPH backend and discuss the benefits and limitations of such an approach. We will also outline the roadmap for supporting ‘delegated storage’ within the dCache releases.

  13. dCache on Steroids - Delegated Storage Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mkrtchyan, Tigran; Adeyemi, F.; Ashish, A.

    For over a decade, dCache.org has delivered a robust software used at more than 80 Universities and research institutes around the world, allowing these sites to provide reliable storage services for the WLCG experiments as well as many other scientific communities. The flexible architecture of dCache allows running it in a wide variety of configurations and platforms - from a SoC based all-in-one Raspberry-Pi up to hundreds of nodes in a multipetabyte installation. Due to lack of managed storage at the time, dCache implemented data placement, replication and data integrity directly. Today, many alternatives are available: S3, GlusterFS, CEPH andmore » others. While such solutions position themselves as scalable storage systems, they cannot be used by many scientific communities out of the box. The absence of community-accepted authentication and authorization mechanisms, the use of product specific protocols and the lack of namespace are some of the reasons that prevent wide-scale adoption of these alternatives. Most of these limitations are already solved by dCache. By delegating low-level storage management functionality to the above-mentioned new systems and providing the missing layer through dCache, we provide a solution which combines the benefits of both worlds - industry standard storage building blocks with the access protocols and authentication required by scientific communities. In this paper, we focus on CEPH, a popular software for clustered storage that supports file, block and object interfaces. CEPH is often used in modern computing centers, for example as a backend to OpenStack services. We will show prototypes of dCache running with a CEPH backend and discuss the benefits and limitations of such an approach. As a result, we will also outline the roadmap for supporting ‘delegated storage’ within the dCache releases.« less

  14. Low-cost, high-speed back-end processing system for high-frequency ultrasound B-mode imaging.

    PubMed

    Chang, Jin Ho; Sun, Lei; Yen, Jesse T; Shung, K Kirk

    2009-07-01

    For real-time visualization of the mouse heart (6 to 13 beats per second), a back-end processing system involving high-speed signal processing functions to form and display images has been developed. This back-end system was designed with new signal processing algorithms to achieve a frame rate of more than 400 images per second. These algorithms were implemented in a simple and cost-effective manner with a single field-programmable gate array (FPGA) and software programs written in C++. The operating speed of the back-end system was investigated by recording the time required for transferring an image to a personal computer. Experimental results showed that the back-end system is capable of producing 433 images per second. To evaluate the imaging performance of the back-end system, a complete imaging system was built. This imaging system, which consisted of a recently reported high-speed mechanical sector scanner assembled with the back-end system, was tested by imaging a wire phantom, a pig eye (in vitro), and a mouse heart (in vivo). It was shown that this system is capable of providing high spatial resolution images with fast temporal resolution.

  15. Low-Cost, High-Speed Back-End Processing System for High-Frequency Ultrasound B-Mode Imaging

    PubMed Central

    Chang, Jin Ho; Sun, Lei; Yen, Jesse T.; Shung, K. Kirk

    2009-01-01

    For real-time visualization of the mouse heart (6 to 13 beats per second), a back-end processing system involving high-speed signal processing functions to form and display images has been developed. This back-end system was designed with new signal processing algorithms to achieve a frame rate of more than 400 images per second. These algorithms were implemented in a simple and cost-effective manner with a single field-programmable gate array (FPGA) and software programs written in C++. The operating speed of the back-end system was investigated by recording the time required for transferring an image to a personal computer. Experimental results showed that the back-end system is capable of producing 433 images per second. To evaluate the imaging performance of the back-end system, a complete imaging system was built. This imaging system, which consisted of a recently reported high-speed mechanical sector scanner assembled with the back-end system, was tested by imaging a wire phantom, a pig eye (in vitro), and a mouse heart (in vivo). It was shown that this system is capable of providing high spatial resolution images with fast temporal resolution. PMID:19574160

  16. Software for Improved Extraction of Data From Tape Storage

    NASA Technical Reports Server (NTRS)

    Cheng, Chiu-Fu

    2002-01-01

    A computer program has been written to replace the original software of Racal Storeplex Delta tape recorders, which are still used at Stennis Space Center but have been discontinued by the manufacturer. Whereas the original software could be activated by a command-line interface only, the present software offers the option of a command-line or graphical user interface. The present software also offers the option of batch-file operation (activation by a file that contains command lines for operations performed consecutively). The present software is also more reliable than was the original software: The original software was plagued by several deficiencies that made it difficult to execute, modify, and test. In addition, when using the original software to extract data that had been recorded within specified intervals of time, the resolution with which one could control starting and stopping times was no finer than about a second (or, in some cases, several seconds). In contrast, the present software is capable of controlling playback times to within 1/100 second of times specified by the user, assuming that the tape-recorder clock is accurate to within 1/100 second.

  17. Storage Media for Microcomputers.

    ERIC Educational Resources Information Center

    Trautman, Rodes

    1983-01-01

    Reviews computer storage devices designed to provide additional memory for microcomputers--chips, floppy disks, hard disks, optical disks--and describes how secondary storage is used (file transfer, formatting, ingredients of incompatibility); disk/controller/software triplet; magnetic tape backup; storage volatility; disk emulator; and…

  18. Jefferson Lab Mass Storage and File Replication Services

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ian Bird; Ying Chen; Bryan Hess

    Jefferson Lab has implemented a scalable, distributed, high performance mass storage system - JASMine. The system is entirely implemented in Java, provides access to robotic tape storage and includes disk cache and stage manager components. The disk manager subsystem may be used independently to manage stand-alone disk pools. The system includes a scheduler to provide policy-based access to the storage systems. Security is provided by pluggable authentication modules and is implemented at the network socket level. The tape and disk cache systems have well defined interfaces in order to provide integration with grid-based services. The system is in production andmore » being used to archive 1 TB per day from the experiments, and currently moves over 2 TB per day total. This paper will describe the architecture of JASMine; discuss the rationale for building the system, and present a transparent 3rd party file replication service to move data to collaborating institutes using JASMine, XM L, and servlet technology interfacing to grid-based file transfer mechanisms.« less

  19. 40 CFR 63.493 - Back-end process provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.493 Back-end process provisions. Owners and operators of new and existing affected sources shall comply with the requirements in...

  20. Backend Control Processor for a Multi-Processor Relational Database Computer System.

    DTIC Science & Technology

    1984-12-01

    SCHOOL OF ENGI. UNCRSIFID MPONTIFF DEC 84 AFXT/GCS/ENG/84D-22 F/O 9/2 L ommhhhhmhhml mhhhommhhhhhm i-2 8 -- U0. 11111= Q. 2 111.8IIII- 1111111..6...THESIS Presented to the Faculty of the School of Engineering of the Air Force Institute of Technology Air University In Partial Fulfillment of the...development of a Backend Multi-Processor Relational Database Computer System. This thesis addresses a single component of this system, the Backend Control

  1. High-Density Digital Data Storage System

    NASA Technical Reports Server (NTRS)

    Wright, Kenneth D.; Gray, David L.

    1995-01-01

    High-density digital data storage system designed for cost-effective storage of large amounts of information acquired during experiments. System accepts up to 20 channels of 16-bit digital data with overall transfer rates of 500 kilobytes per second. Data recorded on 8-millimeter magnetic tape in cartridges, each capable of holding up to five gigabytes of data. Each cartridge mounted on one of two tape drives. Operator chooses to use either or both of drives. One drive used for primary storage of data while other can be used to make a duplicate record of data. Alternatively, other drive serves as backup data-storage drive when primary one fails.

  2. Tape transport mechanism

    DOEpatents

    Groh, Edward F.; McDowell, William; Modjeski, Norbert S.; Keefe, Donald J.; Groer, Peter

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer.

  3. Modeling and Simulation of Voids in Composite Tape Winding Process Based on Domain Superposition Technique

    NASA Astrophysics Data System (ADS)

    Deng, Bo; Shi, Yaoyao

    2017-11-01

    The tape winding technology is an effective way to fabricate rotationally composite materials. Nevertheless, some inevitable defects will seriously influence the performance of winding products. One of the crucial ways to identify the quality of fiber-reinforced composite material products is examining its void content. Significant improvement in products' mechanical properties can be achieved by minimizing the void defect. Two methods were applied in this study, finite element analysis and experimental testing, respectively, to investigate the mechanism of how void forming in composite tape winding processing. Based on the theories of interlayer intimate contact and Domain Superposition Technique (DST), a three-dimensional model of prepreg tape void with SolidWorks has been modeled in this paper. Whereafter, ABAQUS simulation software was used to simulate the void content change with pressure and temperature. Finally, a series of experiments were performed to determine the accuracy of the model-based predictions. The results showed that the model is effective for predicting the void content in the composite tape winding process.

  4. Immediate Effects of Ankle Balance Taping with Kinesiology Tape for Amateur Soccer Players with Lateral Ankle Sprain: A Randomized Cross-Over Design

    PubMed Central

    Kim, Myoung Kwon; Shin, Young Jun

    2017-01-01

    Background The objective of this study was to investigate the immediate effect on gait function when ankle balance taping is applied to amateur soccer players with lateral ankle sprain. Material/Methods A cross-over randomized design was used. Twenty-two soccer players with an ankle sprain underwent 3 interventions in a random order. Subjects were randomly assigned to ankle balance taping, placebo taping, and no taping groups. The assessment was performed using the GAITRite portable walkway system, which records the location and timing of each footfall during ambulation. Results Significant differences were found in the velocity, step length, stride length, and H-H base support among the 3 different taping methods (p<0.05). The ankle balance taping group showed significantly greater velocity, step length, and stride length in comparison to the placebo and no taping group. The ankle balance taping group showed a statistically significant decrease (p<0.05) in the H-H base support compared to the placebo and no taping groups, and the placebo group showed significantly greater velocity in comparison to the no taping group (p<0.05). Conclusions We conclude that ankle balance taping that uses kinesiology tape instantly increased the walking ability of amateur soccer players with lateral ankle sprain. Therefore, ankle balance taping is a useful alternative to prevent and treat ankle sprain of soccer players. PMID:29158472

  5. Roles of Poly(propylene Glycol) During Solvent-Based Lamination of Ceramic Green Tapes

    NASA Technical Reports Server (NTRS)

    Suppakarn, Nitinat; Ishida, Hatsuo; Cawley, James D.; Levine, Stanley R. (Technical Monitor)

    2000-01-01

    Solvent lamination for alumina green tapes is readily accomplished using a mixture of ethanol, toluene and poly(propylene glycol). After lamination, the PPG is clearly present as a discrete film at the interface between the laminated tapes. This condition, however, does not generate delamination during firing. Systematic sets of experiments are undertaken to determine the role of PPG in the lamination process and, specifically, the mechanism by which it is redistributed during subsequent processing. PPG slowly diffuses through the organic binder film at room temperature. The PPG diffusion rapidly increases as temperature is increased to 80 C. The key to the efficiency of adhesives during green-tape lamination is mutual solubility of the nonvolatile component of the glue and the base polymeric binder.

  6. Tape tracking and handling for magnetic tape recorders. [aboard spacecraft

    NASA Technical Reports Server (NTRS)

    Paroby, W.; Disilvestre, R.

    1975-01-01

    One of the critical performance and life limiting elements of a spacecraft tape recorder instrumentation system which has received little attention in technical literature is magnetic tape tracking and handling technology. This technology is required to understand how to gently transfer tape from one reel to another with proper alignment and a desirable uniform velocity at the read and write transducer heads. The increased demand for high data rate (i.e., multi-track spacecraft recording instrumentation systems), coupled with performance under extreme environmental conditions, requires a thorough knowledge of the various parameters which establish an optimum designed tape tracking and handling system. Stress analysis techniques are required to evaluate these parameters substantiated with test tape tracking data, to show the effect of each parameter on a tape recorder instrumentation tracking system. The technology is applicable to ground type tape recorders where the detrimental effects of edge guidance can be eliminated.

  7. Five year magnetic tape for unattended satellite tape recorders

    NASA Technical Reports Server (NTRS)

    Benn, G. S. L.; Gutfreund, K.

    1972-01-01

    The development and fabrication of a quantity of long life magnetic tape with properties selected specifically for unattended operation in spacecraft tape recorders was studied. A detailed analytical consideration of various binder systems was undertaken. This included the chemical aspects of the binders, cohesion and adhesion effects, stability and the mechanical and physical properties. The ability to form free films of these polymers and their combination with various oxide loadings and other additives allowed a rapid selection of four polymer candidates for a five year magnetic tape. Samples were evaluated under actual running conditions which included physical, magnetic, and extensive life testing. These sample tapes withstood 50,000 bidirectional tape passes under fairly harsh operating conditions.

  8. Building an organic block storage service at CERN with Ceph

    NASA Astrophysics Data System (ADS)

    van der Ster, Daniel; Wiebalck, Arne

    2014-06-01

    Emerging storage requirements, such as the need for block storage for both OpenStack VMs and file services like AFS and NFS, have motivated the development of a generic backend storage service for CERN IT. The goals for such a service include (a) vendor neutrality, (b) horizontal scalability with commodity hardware, (c) fault tolerance at the disk, host, and network levels, and (d) support for geo-replication. Ceph is an attractive option due to its native block device layer RBD which is built upon its scalable, reliable, and performant object storage system, RADOS. It can be considered an "organic" storage solution because of its ability to balance and heal itself while living on an ever-changing set of heterogeneous disk servers. This work will present the outcome of a petabyte-scale test deployment of Ceph by CERN IT. We will first present the architecture and configuration of our cluster, including a summary of best practices learned from the community and discovered internally. Next the results of various functionality and performance tests will be shown: the cluster has been used as a backend block storage system for AFS and NFS servers as well as a large OpenStack cluster at CERN. Finally, we will discuss the next steps and future possibilities for Ceph at CERN.

  9. A Layered Solution for Supercomputing Storage

    ScienceCinema

    Grider, Gary

    2018-06-13

    To solve the supercomputing challenge of memory keeping up with processing speed, a team at Los Alamos National Laboratory developed two innovative memory management and storage technologies. Burst buffers peel off data onto flash memory to support the checkpoint/restart paradigm of large simulations. MarFS adds a thin software layer enabling a new tier for campaign storage—based on inexpensive, failure-prone disk drives—between disk drives and tape archives.

  10. Optical Disks Compete with Videotape and Magnetic Storage Media: Part I.

    ERIC Educational Resources Information Center

    Urrows, Henry; Urrows, Elizabeth

    1988-01-01

    Describes the latest technology in videotape cassette systems and other magnetic storage devices and their possible effects on optical data disks. Highlights include Honeywell's Very Large Data Store (VLDS); Exabyte's tape cartridge storage system; standards for tape drives; and Masstor System's videotape cartridge system. (LRW)

  11. A media maniac's guide to removable mass storage media

    NASA Technical Reports Server (NTRS)

    Kempster, Linda S.

    1996-01-01

    This paper addresses at a high level, the many individual technologies available today in the removable storage arena including removable magnetic tapes, magnetic floppies, optical disks and optical tape. Tape recorders represented below discuss logitudinal, serpantine, logitudinal serpantine,and helical scan technologies. The magnetic floppies discussed will be used for personal electronic in-box applications.Optical disks still fill the role for dense long-term storage. The media capacities quoted are for native data. In some cases, 2 KB ASC2 pages or 50 KB document images will be referenced.

  12. Tape Placement Head for Applying Thermoplastic Tape to an Object

    NASA Technical Reports Server (NTRS)

    Cope, Ralph D. (Inventor); Funck, Steve B. (Inventor); Gruber, Mark B. (Inventor); Lamontia, Mark A. (Inventor); Johnson, Anthony D. (Inventor)

    2008-01-01

    A tape placement head for applying thermoplastic tape to an object includes a heated feeder which guides the tape/tow to a heated zone. The heated zone has a line compactor having a single row of at least one movable heated member. An area compactor is located in the heated zone downstream from the line compactor. The area compactor includes a plurality of rows of movable feet which are extendable toward the tape/tow different distances with respect to each other to conform to the shape of the object. A shim is located between the heated compactors and the tape/tow. A chilled compactor is in a chilled zone downstream from the heated zone. The chilled zone includes a line chilled compactor and an area chilled compactor. A chilled shim is mounted between the chilled compactor and the tape/tow.

  13. Tape functionality: sonographic tape characteristics and outcome after TVT incontinence surgery.

    PubMed

    Kociszewski, Jacek; Rautenberg, Oliver; Perucchini, Daniele; Eberhard, Jakob; Geissbühler, Verena; Hilgers, Reinhard; Viereck, Volker

    2008-01-01

    To investigate tension-free vaginal tape (TVT) position and shape using ultrasound (US) and correlate the findings to outcome. The results of TVT surgery were investigated in 72 women with urodynamic stress urinary incontinence. The main outcome parameters were US tape position in relation to the urethra and dynamic changes in TVT shape at rest and during straining. Sixty-two patients (86%) were continent, 6 (8%) significantly improved, and the operation failed in four cases (6%). The median tape position was at 66% of the urethral length measured by US. The median tape-urethra-lumen distance was 3.8 mm at rest. Tape placement in the upper or lower quarter of the urethra was associated with a higher failure rate. Tapes positioned less than 3 mm from the urethra significantly increased postoperative complications (P < 0.0001). The tape was flat at rest and curved during straining in 44 (61%) patients; 98% (43/44) of these women were continent after surgery. An unchanged tape shape was associated with a poorer outcome (P = 0.00038). Patients with a flat tape at rest and during straining failed in 25% and patients with a permanent curved shape in 10%. TVT position relative to the patient's urethra seems to play a role in treatment outcome. Outcome was best in patients with dynamic change in tape shape during straining and location of the tape at the junction between the lower and middle urethra and at least 3 mm from the urethral lumen. (c) 2008 Wiley-Liss, Inc.

  14. Mass storage at NSA

    NASA Technical Reports Server (NTRS)

    Shields, Michael F.

    1993-01-01

    The need to manage large amounts of data on robotically controlled devices has been critical to the mission of this Agency for many years. In many respects this Agency has helped pioneer, with their industry counterparts, the development of a number of products long before these systems became commercially available. Numerous attempts have been made to field both robotically controlled tape and optical disk technology and systems to satisfy our tertiary storage needs. Custom developed products were architected, designed, and developed without vendor partners over the past two decades to field workable systems to handle our ever increasing storage requirements. Many of the attendees of this symposium are familiar with some of the older products, such as: the Braegen Automated Tape Libraries (ATL's), the IBM 3850, the Ampex TeraStore, just to name a few. In addition, we embarked on an in-house development of a shared disk input/output support processor to manage our every increasing tape storage needs. For all intents and purposes, this system was a file server by current definitions which used CDC Cyber computers as the control processors. It served us well and was just recently removed from production usage.

  15. Developments of FPGA-based digital back-ends for low frequency antenna arrays at Medicina radio telescopes

    NASA Astrophysics Data System (ADS)

    Naldi, G.; Bartolini, M.; Mattana, A.; Pupillo, G.; Hickish, J.; Foster, G.; Bianchi, G.; Lingua, A.; Monari, J.; Montebugnoli, S.; Perini, F.; Rusticelli, S.; Schiaffino, M.; Virone, G.; Zarb Adami, K.

    In radio astronomy Field Programmable Gate Array (FPGA) technology is largely used for the implementation of digital signal processing techniques applied to antenna arrays. This is mainly due to the good trade-off among computing resources, power consumption and cost offered by FPGA chip compared to other technologies like ASIC, GPU and CPU. In the last years several digital backend systems based on such devices have been developed at the Medicina radio astronomical station (INAF-IRA, Bologna, Italy). Instruments like FX correlator, direct imager, beamformer, multi-beam system have been successfully designed and realized on CASPER (Collaboration for Astronomy Signal Processing and Electronics Research, https://casper.berkeley.edu) processing boards. In this paper we present the gained experience in this kind of applications.

  16. Cloud-Based Data Storage

    ERIC Educational Resources Information Center

    Waters, John K.

    2011-01-01

    The vulnerability and inefficiency of backing up data on-site is prompting school districts to switch to more secure, less troublesome cloud-based options. District auditors are pushing for a better way to back up their data than the on-site, tape-based system that had been used for years. About three years ago, Hendrick School District in…

  17. Back-end and interface implementation of the STS-XYTER2 prototype ASIC for the CBM experiment

    NASA Astrophysics Data System (ADS)

    Kasinski, K.; Szczygiel, R.; Zabolotny, W.

    2016-11-01

    Each front-end readout ASIC for the High-Energy Physics experiments requires robust and effective hit data streaming and control mechanism. A new STS-XYTER2 full-size prototype chip for the Silicon Tracking System and Muon Chamber detectors in the Compressed Baryonic Matter experiment at Facility for Antiproton and Ion Research (FAIR, Germany) is a 128-channel time and amplitude measuring solution for silicon microstrip and gas detectors. It operates at 250 kHit/s/channel hit rate, each hit producing 27 bits of information (5-bit amplitude, 14-bit timestamp, position and diagnostics data). The chip back-end implements fast front-end channel read-out, timestamp-wise hit sorting, and data streaming via a scalable interface implementing the dedicated protocol (STS-HCTSP) for chip control and hit transfer with data bandwidth from 9.7 MHit/s up to 47 MHit/s. It also includes multiple options for link diagnostics, failure detection, and throttling features. The back-end is designed to operate with the data acquisition architecture based on the CERN GBTx transceivers. This paper presents the details of the back-end and interface design and its implementation in the UMC 180 nm CMOS process.

  18. SDAI: a key piece of software to manage the new wideband backend at Robledo

    NASA Astrophysics Data System (ADS)

    Rizzo, J. R.; Gutiérrez Bustos, M.; Kuiper, T. B. H.; Cernicharo, J.; Sotuela, I.; Pedreira, A.

    2012-09-01

    A joint collaborative project was recently developed to provide the Madrid Deep Space Communications Complex with a state-of-the-art wideband backend. This new backend provides from 100MHz to 6 GHz of instantaneous bandwidth, and spectral resolutions from 6 to 200 kHz. The backend includes a new intermediate-frequency processor, as well as a FPGA-based FFT spectrometer, which manage thousands of spectroscopic channels in real time. All these equipment need to be controlled and operated by a common software, which has to synchronize activities among affected devices, and also with the observing program. The final output should be a calibrated spectrum, readable by standard radio astronomical tools for further processing. The developed software at this end is named "Spectroscopic Data Acquisition Interface" (SDAI). SDAI is written in python 2.5, using PyQt4 for the User Interface. By an ethernet socket connection, SDAI receives astronomical information (source, frequencies, Doppler correction, etc.) and the antenna status from the observing program. Then it synchronizes the observations at the required frequency by tuning the synthesizers through their USB ports; finally SDAI controls the FFT spectrometers through UDP commands sent by sockets. Data are transmitted from the FFT spectrometers by TCP sockets, and written as standard FITS files. In this paper we describe the modules built, depict a typical observing session, and show some astronomical results using SDAI.

  19. 40 CFR 63.497 - Back-end process provisions-monitoring provisions for control and recovery devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Back-end process provisions-monitoring... Polymers and Resins § 63.497 Back-end process provisions—monitoring provisions for control and recovery devices. (a) An owner or operator complying with the residual organic HAP limitations in § 63.494(a) using...

  20. Magnetic Tape Recording

    NASA Technical Reports Server (NTRS)

    Athey, Skipwith W.

    1966-01-01

    NASA's contribution to tape recorder technology may appear to lie in such glamorous devices as the tape recorders of the Tiros and Nimbus satellites which receive signals carrying weather information during an orbit around the earth and then transmit those signals back to the ground when the satellite is in view of ground stations. These quite important recording devices are, however, only useful as members of a complex hierarchy of devices all of which participate in the ultimate process of obtaining information from NASA's efforts. Their existence and utility is based on the existence of many more prosaic recording devices which have been involved in the development of such spectacular units.

  1. VLBI Digital-Backend Intercomparison Test Report

    NASA Technical Reports Server (NTRS)

    Whitney, Alan; Beaudoin, Christopher; Cappallo, Roger; Niell, Arthur; Petrachenko, Bill; Ruszczyk, Chester A.; Titus, Mike

    2013-01-01

    Issues related to digital-backend (DBE) systems can be difficult to evaluate in either local tests or actual VLBI experiments. The 2nd DBE intercomparison workshop at Haystack Observatory on 25-26 October 2012 provided a forum to explicitly address validation and interoperability issues among independent global developers of DBE equipment. This special report discusses the workshop. It identifies DBE systems that were tested at the workshop, describes the test objectives and procedures, and reports and discusses the results of the testing.

  2. Survey of Scientific-Technical Tape Services.

    ERIC Educational Resources Information Center

    Carroll, Kenneth D., Ed.

    The results of a survey of commercially available tape services which can provide libraries and information centers with data bases of scientific and technical literature are reported. During the past few years there has been an increasing number of tape services entering the information resources market. Each of these services makes available to…

  3. The Catalog: A Flexible Data Structure for Magnetic Tape.

    ERIC Educational Resources Information Center

    Kay, Martin; Ziehe, Theodore

    This report outlines a generalized storage scheme for large files of highly structured data, or catalogs, and describes their realization on magnetic tape. Each datum, large or small, is assigned to one of a number of data classes of which a user may define any number. The over-all organization of a catalog is given by a map that imposes a tree…

  4. A high performance hierarchical storage management system for the Canadian tier-1 centre at TRIUMF

    NASA Astrophysics Data System (ADS)

    Deatrich, D. C.; Liu, S. X.; Tafirout, R.

    2010-04-01

    We describe in this paper the design and implementation of Tapeguy, a high performance non-proprietary Hierarchical Storage Management (HSM) system which is interfaced to dCache for efficient tertiary storage operations. The system has been successfully implemented at the Canadian Tier-1 Centre at TRIUMF. The ATLAS experiment will collect a large amount of data (approximately 3.5 Petabytes each year). An efficient HSM system will play a crucial role in the success of the ATLAS Computing Model which is driven by intensive large-scale data analysis activities that will be performed on the Worldwide LHC Computing Grid infrastructure continuously. Tapeguy is Perl-based. It controls and manages data and tape libraries. Its architecture is scalable and includes Dataset Writing control, a Read-back Queuing mechanism and I/O tape drive load balancing as well as on-demand allocation of resources. A central MySQL database records metadata information for every file and transaction (for audit and performance evaluation), as well as an inventory of library elements. Tapeguy Dataset Writing was implemented to group files which are close in time and of similar type. Optional dataset path control dynamically allocates tape families and assign tapes to it. Tape flushing is based on various strategies: time, threshold or external callbacks mechanisms. Tapeguy Read-back Queuing reorders all read requests by using an elevator algorithm, avoiding unnecessary tape loading and unloading. Implementation of priorities will guarantee file delivery to all clients in a timely manner.

  5. [Laryngeal Tube Position Shift after Chest Compression: Comparison of Fixation Methods Using Durapore Tape, Multipore Tape, or a Neck Tape].

    PubMed

    Seno, Hisayo; Komasawa, Nobuyasu; Fujiwara, Shunsuke; Miyazaki, Shinichiro; Tatsumi, Shinichi; Minami, Toshiaki

    2015-05-01

    The laryngeal tube (LT ; Smiths Medical, Minnesota, U. S. A) is an inflatable supraglottic device for emergency airway management such as during chest compression, the instability after insertion remains a problem. We investigated the effectiveness of three fixation methods of LT using a manikin and automated chest compressor. After 10-minute chest compression, LT without fixation was shifted by 0.4 ± 0.1 cm, which was greater than with Durapore tape (0.2 ± 0.1 cm), Multipore tape (0.2 ± 0.1 cm), or a neck tape (0.1 ± 0.1 cm). The shift of the position was smaller with neck tape fixation compared to Durapore or Multipore tape fixation. A fixation neck tape may be useful in stabilizing the inserted position of LT during cardiopulmonary resuscitation.

  6. Tape reading fixture

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Commercially available roller type desk pad provides an efficient and orderly manner of handling rolled paper tapes for proofreading. The fixture, which is modified to accept Flex-O-Writer or similar tapes and roll them in either direction, reduces the chance of damaging or soiling the tapes through repeated handling.

  7. Thermoplastic tape compaction device

    DOEpatents

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.

  8. Thermoplastic tape compaction device

    DOEpatents

    Campbell, Vincent W.

    1994-01-01

    A device for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite.

  9. Thermally Conductive Tape Based on Carbon Nanotube Arrays

    NASA Technical Reports Server (NTRS)

    Kashani, Ali

    2011-01-01

    array of CNTs was measured to be as high as 10 W/K. The high thermal conductivity and the nanoscale size make CNTs ideal as thermal interface materials. The CNT-based thermal tape can be used for the thermal management of microelectronic packages and electronic systems. It also can be integrated with current device technology and packaging. The material would allow for an efficient method to manage excess heat generation without requiring any additional power. Lastly, the CNT tape can be used to enhance thermal contact conductance across two mating surfaces on some NASA missions.

  10. Thermoplastic tape compaction device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin bandmore » of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.« less

  11. TRIO: Burst Buffer Based I/O Orchestration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Teng; Oral, H Sarp; Pritchard, Michael

    The growing computing power on leadership HPC systems is often accompanied by ever-escalating failure rates. Checkpointing is a common defensive mechanism used by scientific applications for failure recovery. However, directly writing the large and bursty checkpointing dataset to parallel filesystem can incur significant I/O contention on storage servers. Such contention in turn degrades the raw bandwidth utilization of storage servers and prolongs the average job I/O time of concurrent applications. Recently burst buffer has been proposed as an intermediate layer to absorb the bursty I/O traffic from compute nodes to storage backend. But an I/O orchestration mechanism is still desiredmore » to efficiently move checkpointing data from bursty buffers to storage backend. In this paper, we propose a burst buffer based I/O orchestration framework, named TRIO, to intercept and reshape the bursty writes for better sequential write traffic to storage severs. Meanwhile, TRIO coordinates the flushing orders among concurrent burst buffers to alleviate the contention on storage server bandwidth. Our experimental results reveal that TRIO can deliver 30.5% higher bandwidth and reduce the average job I/O time by 37% on average for data-intensive applications in various checkpointing scenarios.« less

  12. Specification for wide channel bandwidth one-inch video tape

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

  13. PHOTOELECTRIC CONTROL FOR TAPE POSITIONING

    DOEpatents

    Woody, J.W. Jr.

    1961-07-25

    A control system is described for producing control impulses which may be used to start, stop, and position a magnetic tape with respect to a transducer, and to locate discrete areas on the tape. Means are provided for positive identification of data blocks, exact positioning of the tape under the magnetic head, drive in either direction, accurate skip-over of imperfect regions of the tape, stopping the tape if equipment malfunction results in a failure to detect the block-identifying signals, and starting and stopping those parts of the tape between of the tape drive clutches.

  14. Realization and testing of a deployable space telescope based on tape springs

    NASA Astrophysics Data System (ADS)

    Lei, Wang; Li, Chuang; Zhong, Peifeng; Chong, Yaqin; Jing, Nan

    2017-08-01

    For its compact size and light weight, space telescope with deployable support structure for its secondary mirror is very suitable as an optical payload for a nanosatellite or a cubesat. Firstly the realization of a prototype deployable space telescope based on tape springs is introduced in this paper. The deployable telescope is composed of primary mirror assembly, secondary mirror assembly, 6 foldable tape springs to support the secondary mirror assembly, deployable baffle, aft optic components, and a set of lock-released devices based on shape memory alloy, etc. Then the deployment errors of the secondary mirror are measured with three-coordinate measuring machine to examine the alignment accuracy between the primary mirror and the deployed secondary mirror. Finally modal identification is completed for the telescope in deployment state to investigate its dynamic behavior with impact hammer testing. The results of the experimental modal identification agree with those from finite element analysis well.

  15. Data storage technology comparisons

    NASA Technical Reports Server (NTRS)

    Katti, Romney R.

    1990-01-01

    The role of data storage and data storage technology is an integral, though conceptually often underestimated, portion of data processing technology. Data storage is important in the mass storage mode in which generated data is buffered for later use. But data storage technology is also important in the data flow mode when data are manipulated and hence required to flow between databases, datasets and processors. This latter mode is commonly associated with memory hierarchies which support computation. VLSI devices can reasonably be defined as electronic circuit devices such as channel and control electronics as well as highly integrated, solid-state devices that are fabricated using thin film deposition technology. VLSI devices in both capacities play an important role in data storage technology. In addition to random access memories (RAM), read-only memories (ROM), and other silicon-based variations such as PROM's, EPROM's, and EEPROM's, integrated devices find their way into a variety of memory technologies which offer significant performance advantages. These memory technologies include magnetic tape, magnetic disk, magneto-optic disk, and vertical Bloch line memory. In this paper, some comparison between selected technologies will be made to demonstrate why more than one memory technology exists today, based for example on access time and storage density at the active bit and system levels.

  16. Failure and fatigue characteristics of adhesive athletic tape.

    PubMed

    Bragg, Richard W; Macmahon, John M; Overom, Erin K; Yerby, Scott A; Matheson, Gordon O; Carter, Dennis R; Andriacchi, Thomas P

    2002-03-01

    Athletic tape has been commonly reported to lose much of its structural support after 20 min of exercise. Although many studies have addressed the functional performance characteristics of athletic tape, its mechanical properties are poorly understood. This study examines the failure and fatigue properties of several commonly used athletic tapes. A Web-based survey of professional sports trainers was used to select the following three tapes for the study: Zonas (Johnson & Johnson), Leukotape (Beiersdorf), and Jaylastic (Jaybird & Mais). Using a hydraulic material testing system (MTS), eight samples of each tape were compared in three different mechanical tests: load-to-failure, fatigue testing under load control, and fatigue testing under displacement control. Differences in tape microstructure were used to interpret the results of the mechanical tests. Significant differences (P < 0.001) in failure load, elongation at failure, and stiffness were found from failure tests. Significant differences were also found (P < 0.001) in fatigue behavior under both modes of control. As a representative example, in one normalized displacement control fatigue test after 20 min of cycling, 21% (Zonas), 29% (Leukotape), and 57% (Jaylastic) of the mechanical support was lost. After cycling, all tapes loaded to failure showed increased stiffness (P < 0.001), indicating significant energy absorption during cycling. Observed differences in the tapes' microstructure were qualitatively consistent with the measured differences in their mechanical properties. In understanding the shortcomings of currently available tapes, the results of these tests can now be used as benchmarks with which to compare and develop future tape designs. Ultimately, these improved tapes should reduce ankle injuries among athletes.

  17. Methods of Measuring Stress Relaxation in Composite Tape Springs

    DTIC Science & Technology

    2015-03-26

    plate in order to spread the load evenly and prevent excess torque . The plate also allows for force on the tape spring to be applied to the entire...aluminum squares that can be tightened to the base. The test fixture is secured to the marble base. The tape springs are folded in three locations with...top plate is pressed down by tightening the bolt on each nut. The tightening is complete when the tape spring just begins to create an M shape and

  18. NASTRAN postprocessor program for transient response to input accelerations. [procedure for generating and writing modal input data on tapes using NASTRAN

    NASA Technical Reports Server (NTRS)

    Wingate, R. T.; Jones, T. C.; Stephens, M. V.

    1973-01-01

    The description of a transient analysis program for computing structural responses to input base accelerations is presented. A hybrid modal formulation is used and a procedure is demonstrated for generating and writing all modal input data on user tapes via NASTRAN. Use of several new Level 15 modules is illustrated along with a problem associated with reading the postprocessor program input from a user tape. An example application of the program is presented for the analysis of a spacecraft subjected to accelerations initiated by thrust transients. Experience with the program has indicated it to be very efficient and economical because of its simplicity and small central memory storage requirements.

  19. Robotic tape library system level testing at NSA: Present and planned

    NASA Technical Reports Server (NTRS)

    Shields, Michael F.

    1994-01-01

    In the present of declining Defense budgets, increased pressure has been placed on the DOD to utilize Commercial Off the Shelf (COTS) solutions to incrementally solve a wide variety of our computer processing requirements. With the rapid growth in processing power, significant expansion of high performance networking, and the increased complexity of applications data sets, the requirement for high performance, large capacity, reliable and secure, and most of all affordable robotic tape storage libraries has greatly increased. Additionally, the migration to a heterogeneous, distributed computing environment has further complicated the problem. With today's open system compute servers approaching yesterday's supercomputer capabilities, the need for affordable, reliable secure Mass Storage Systems (MSS) has taken on an ever increasing importance to our processing center's ability to satisfy operational mission requirements. To that end, NSA has established an in-house capability to acquire, test, and evaluate COTS products. Its goal is to qualify a set of COTS MSS libraries, thereby achieving a modicum of standardization for robotic tape libraries which can satisfy our low, medium, and high performance file and volume serving requirements. In addition, NSA has established relations with other Government Agencies to complete this in-house effort and to maximize our research, testing, and evaluation work. While the preponderance of the effort is focused at the high end of the storage ladder, considerable effort will be extended this year and next at the server class or mid range storage systems.

  20. Superconducting properties of multilayered Ag/Bi(Pb)-2223 tapes prepared using pretextured monolayered tapes

    NASA Astrophysics Data System (ADS)

    Syamaprasad, U.; Sarma, M. S.; Guruswamy, P.; Pillai, S. G. K.; Warrier, K. G. K.; Damodaran, A. D.

    1997-02-01

    Multilayered Ag/Bi(Pb)-2223 tapes with high critical current densities 0953-2048/10/2/005/img1 have been fabricated using partially heat treated, textured monolayered tapes. Cut sections of the monolayered tapes have been stacked one over the other and folded together using high-purity silver foil and further rolled and heat treated to obtain multilayered tapes of different thickness with an HTS layer thickness varying from 9 to 0953-2048/10/2/005/img2. A comparison of the superconducting properties of the multilayered tapes with those of monolayered tapes prepared under identical heat treatment conditions shows that the 0953-2048/10/2/005/img3 ratio at 77 K is as high as 0.57. The ratio is found to decrease with a decrease in the HTS core thickness of the multilayered tapes. XRD studies of `banana peeled' samples show that the monolayered tapes at the folding stage acquire a good degree of texturing. The relatively high value of the 0953-2048/10/2/005/img3 ratio obtained in the present case compared with those reported by the existing techniques is attributed to the use of pretextured monolayered tapes.

  1. RESIDUAL RISK ASSESSMENT: MAGNETIC TAPE ...

    EPA Pesticide Factsheets

    This document describes the residual risk assessment for the Magnetic Tape Manufacturing source category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Magnetic Tape Manufacturing source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  2. Feasibility model of a high reliability five-year tape transport, Volume 1. [development, performance, and test results

    NASA Technical Reports Server (NTRS)

    Eshleman, R. L.; Meyers, A. P.; Davidson, W. A.; Gortowski, R. C.; Anderson, M. E.

    1973-01-01

    The development, performance, and test results for the spaceborne magnetic tape transport are discussed. An analytical model of the tape transport was used to optimize its conceptual design. Each of the subsystems was subjected to reliability analyses which included structural integrity, maintenance of system performance within acceptable bounds, and avoidance of fatigue failure. These subsystems were also compared with each other in order to evaluate reliability characteristics. The transport uses no mechanical couplings. Four drive motors, one for each reel and one for each of two capstans, are used in a differential mode. There are two hybrid, spherical, cone tapered-crown rollers for tape guidance. Storage of the magnetic tape is provided by a reel assembly which includes the reel, a reel support structure and bearings, dust seals, and a dc drive motor. A summary of transport test results on tape guidance, flutter, and skew is provided.

  3. Magnetic tape user guide

    NASA Technical Reports Server (NTRS)

    Evans, A. B.; Lee, L. L.

    1985-01-01

    This User Guide provides a general introduction to the structure, use, and handling of magnetic tapes at Langley Research Center (LaRC). The topics covered are tape terminology, physical characteristics, error prevention and detection, and creating, using, and maintaining tapes. Supplementary documentation is referenced where it might be helpful. The documentation is included for the tape utility programs, BLOCK, UNBLOCK, and TAPEDMP, which are available at the Central Scientific Computing Complex at LaRC.

  4. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  5. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  6. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  7. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  8. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate band...

  9. A Layered Solution for Supercomputing Storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grider, Gary

    To solve the supercomputing challenge of memory keeping up with processing speed, a team at Los Alamos National Laboratory developed two innovative memory management and storage technologies. Burst buffers peel off data onto flash memory to support the checkpoint/restart paradigm of large simulations. MarFS adds a thin software layer enabling a new tier for campaign storage—based on inexpensive, failure-prone disk drives—between disk drives and tape archives.

  10. Magnetic Tape Recording for the Eighties

    NASA Technical Reports Server (NTRS)

    Kalil, Ford (Editor)

    1982-01-01

    The practical and theoretical aspects of state-of-the-art magnetic tape recording technology are reviewed. Topics covered include the following: (1) analog and digital magnetic tape recording, (2) tape and head wear, (3) wear testing, (4) magnetic tape certification, (5) care, handling, and management of magnetic tape, (6) cleaning, packing, and winding of magnetic tape, (7) tape reels, bands, and packaging, (8) coding techniques for high-density digital recording, and (9) tradeoffs of coding techniques.

  11. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  12. Kinesio Taping Fundamentals for the Equine Athlete.

    PubMed

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. High Fidelity Tape Transfer Printing Based On Chemically Induced Adhesive Strength Modulation

    NASA Astrophysics Data System (ADS)

    Sim, Kyoseung; Chen, Song; Li, Yuhang; Kammoun, Mejdi; Peng, Yun; Xu, Minwei; Gao, Yang; Song, Jizhou; Zhang, Yingchun; Ardebili, Haleh; Yu, Cunjiang

    2015-11-01

    Transfer printing, a two-step process (i.e. picking up and printing) for heterogeneous integration, has been widely exploited for the fabrication of functional electronics system. To ensure a reliable process, strong adhesion for picking up and weak or no adhesion for printing are required. However, it is challenging to meet the requirements of switchable stamp adhesion. Here we introduce a simple, high fidelity process, namely tape transfer printing(TTP), enabled by chemically induced dramatic modulation in tape adhesive strength. We describe the working mechanism of the adhesion modulation that governs this process and demonstrate the method by high fidelity tape transfer printing several types of materials and devices, including Si pellets arrays, photodetector arrays, and electromyography (EMG) sensors, from their preparation substrates to various alien substrates. High fidelity tape transfer printing of components onto curvilinear surfaces is also illustrated.

  14. Kinesio taping or sham taping in knee osteoarthritis? A randomized, double-blind, sham-controlled trial.

    PubMed

    Kocyigit, Figen; Turkmen, Mehmet Besir; Acar, Merve; Guldane, Nezahat; Kose, Tugce; Kuyucu, Ersin; Erdil, Mehmet

    2015-11-01

    To compare effects of kinesio taping with sham taping at the end of 3 consecutive taping periods in knee osteoarthritis. 41 patients diagnosed with knee osteoarthritis according to American College of Rheumatology were randomized to receive either KT or sham taping. Baseline evaluations included a visual analog scale (VAS) for activity and nocturnal pain, Lequesne index for functional assessment and Nottingham Health Profile (NHP) for the quality of life. Taping was applied every four days, three times, and all of the assessments were repeated at the end of the treatment period. In both groups VAS for activity pain, VAS for nocturnal pain, Lequesne index score, NHP score decreased significantly. NHP energy scores were different significantly between the groups in favor of sham taping at the end of the 12-day period. Our findings indicate inconclusive evidence of a beneficial effect of kinesio taping over sham taping in knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Effect of Tape Burnishing and Drive Use on Head Wear in Rotary Tape Drives

    NASA Astrophysics Data System (ADS)

    Bhushan, Bharat; Anderson, Reid M.; Koinkar, Vilas N.

    Three types of 12.7-mm wide metal particle tapes were studied. One of the tapes was calendered, whereas the other two tapes were additionally burnished one or two times using a proprietary process. Each type of tape was studied after 100 passes in the BetaCam SP drive and also in the virgin (0 pass) state. It was reported that in the case of the unburnished tape, head wear was high in the first pass and decreased during use. However, head wear for the double burnished tape was low for the first pass and increased during use. Whereas in the single burnished tape, head wear was low in the first pass and remained low. The objective of this study is to understand the mechanisms for loss and growth of head wear by correlating the surface characteristics of the tapes to head wear rate and to determine the changes in the surface characteristics occurring from 0 to 100 passes in the drive. It was found that summit density, mean and rms summit height, and mean and rms summit curvature correlate well to the head wear data. During manufacture and use in the drive, as the summit density, mean and rms summit height, and mean and rms summit curvature decrease, the head wear rate decreases. The mechanism for head wear is the initial ploughing of dense, sharp and high tape asperities into the surface of the head material resulting in a high head wear rate and a high coefficient of friction. Double burnishing during manufacturing removes high asperities, thus making the tape very smooth and possibly results in high adhesion and head wear growth with use. Chemical changes of the tape surface during double burnishing (not part of this study) also may be responsible for head wear growth during use.

  16. Main image file tape description

    USGS Publications Warehouse

    Warriner, Howard W.

    1980-01-01

    This Main Image File Tape document defines the data content and file structure of the Main Image File Tape (MIFT) produced by the EROS Data Center (EDC). This document also defines an INQUIRY tape, which is just a subset of the MIFT. The format of the INQUIRY tape is identical to the MIFT except for two records; therefore, with the exception of these two records (described elsewhere in this document), every remark made about the MIFT is true for the INQUIRY tape.

  17. Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.

    PubMed

    Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A

    2001-01-01

    Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A

  18. Industrial Tape

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Scotch Brand Tape 364 was developed for NASA by 3M Company to protect electrical instrumentation coils and fluid lines from rocket launch blast conditions. It is an aluminized glass cloth tape which can withstand very high temperatures, is easily applied to compound surfaces, has excellent solar energy reflectance, and does not present an electrostatic hazard. It has potential automotive, transportation, and building construction applications.

  19. Tape-Drop Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.; Marchello, Joseph M.

    1998-01-01

    Composite parts of nonuniform thickness can be fabricated by in-situ automated tape placement (ATP) if the tape can be started and stopped at interior points of the part instead of always at its edges. This technique is termed start/stop-on-the-part, or, alternatively, tape-add/tape-drop. The resulting thermal transients need to be managed in order to achieve net shape and maintain uniform interlaminar weld strength and crystallinity. Starting-on-the-part has been treated previously. This paper continues the study with a thermal analysis of stopping-on-the-part. The thermal source is switched off when the trailing end of the tape enters the nip region of the laydown/consolidation head. The thermal transient is determined by a Fourier-Laplace transform solution of the two-dimensional, time-dependent thermal transport equation. This solution requires that the Peclet number Pe (the dimensionless ratio of inertial to diffusive heat transport) be independent of time and much greater than 1. Plotted isotherms show that the trailing tape-end cools more rapidly than the downstream portions of tape. This cooling can weaken the bond near the tape end; however the length of the affected region is found to be less than 2 mm. To achieve net shape, the consolidation head must continue to move after cut-off until the temperature on the weld interface decreases to the glass transition temperature. The time and elapsed distance for this condition to occur are computed for the Langley ATP robot applying PEEK/carbon fiber composite tape and for two upgrades in robot performance. The elapsed distance after cut-off ranges from about 1 mm for the present robot to about 1 cm for the second upgrade.

  20. Hygroscopic properties of magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Cuddihy, E. F.

    1976-01-01

    Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

  1. Kinesiology taping and the world wide web: a quality and content analysis of internet-based information.

    PubMed

    Beutel, Bryan G; Cardone, Dennis A

    2014-10-01

    Due to limited regulation of websites, the quality and content of online health-related information has been questioned as prior studies have shown that websites often misrepresent orthopaedic conditions and treatments. Kinesio tape has gained popularity among athletes and the general public despite limited evidence supporting its efficacy. The primary objective of this study was to assess the quality and content of Internet-based information on Kinesio taping. An Internet search using the terms "Kinesio tape" and "kinesiology tape" was performed using the Google search engine. Websites returned within the first two pages of results, as well as hyperlinks embedded within these sites, were included in the study. These sites were subsequently classified by type. The quality of the website was determined by the Health On the Net (HON) score, an objective metric based upon recommendations from the United Nations for the ethical representation of health information. A content analysis was performed by noting specific misleading versus balanced features in each website. A total of 31 unique websites were identified. The majority of the websites (71%) were commercial. Out of a total possible 16 points, the mean HON score among the websites was 8.9 points (SD 2.2 points). The number of misleading features was significantly higher than the balanced features (p < 0.001). Fifty-eight percent of sites used anecdotal testimonials to promote the product. Only small percentages of websites discussed complications, alternatives, or provided accurate medical outcomes. Overall, commercial sites had a greater number of misleading features compared to non-commercial sites (p = 0.01). Websites discussing Kinesio tape are predominantly of poor quality and present misleading, imbalanced information. It is of ever-increasing importance that healthcare providers work to ensure that reliable, balanced, and accurate information be available to Internet users. IV.

  2. Automated Tape Laying Machine for Composite Structures.

    DTIC Science & Technology

    The invention comprises an automated tape laying machine, for laying tape on a composite structure. The tape laying machine has a tape laying head...neatly cut. The automated tape laying device utilizes narrow width tape to increase machine flexibility and reduce wastage.

  3. 40 CFR 63.497 - Back-end process provisions-monitoring provisions for control and recovery devices used to comply...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Back-end process provisions-monitoring... Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.497 Back-end process... limitations. (a) An owner or operator complying with the residual organic HAP limitations in § 63.494(a)(1...

  4. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    PubMed

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p < 0.05) and after detaching the tape (p < 0.01) compared to the first measurement. Our results indicate that the perception of the area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Design of digital voice storage and playback system

    NASA Astrophysics Data System (ADS)

    Tang, Chao

    2018-03-01

    Based on STC89C52 chip, this paper presents a single chip microcomputer minimum system, which is used to realize the logic control of digital speech storage and playback system. Compared with the traditional tape voice recording system, the system has advantages of small size, low power consumption, The effective solution of traditional voice recording system is limited in the use of electronic and information processing.

  6. Tape recorder failure investigation

    NASA Technical Reports Server (NTRS)

    Higgins, M. D.; Loewenthal, S. H.; Carnahan, C. C.; Snyder, G. L.

    1996-01-01

    Two end-item tape recorders lost 4:1 mode data recording mode capability at less than half of their 1 6,000-cycle, 4-year operating life. Subsequent life tests on two spare recorders also experienced 4:1 mode data loss at 8,000 and 11,700 cycles. Tear down inspection after completion of the life tests showed that the tape had worn through the alfesil record and reproduce heads. An investigation was initiated to understand the cause of excessive tape head wear and the reasons why the 4:1 mode data rate, low-speed mode is more damaging than the 1:1 mode data rate, high-speed recording mode. The objective was to establish how operating conditions (tape speed, humidity, temperature, stop/start cycles) affects head life with the goal of extending head life on the remaining in-service tape recorders. Another interest was to explain why an earlier vendor life test showed capability beyond 16,000 cycles.

  7. NSSDC Conference on Mass Storage Systems and Technologies for Space and Earth Science Applications, volume 1

    NASA Technical Reports Server (NTRS)

    Kobler, Benjamin (Editor); Hariharan, P. C. (Editor); Blasso, L. G. (Editor)

    1992-01-01

    Papers and viewgraphs from the conference are presented. This conference served as a broad forum for the discussion of a number of important issues in the field of mass storage systems. Topics include magnetic disk and tape technologies, optical disks and tape, software storage and file management systems, and experiences with the use of a large, distributed storage system. The technical presentations describe, among other things, integrated mass storage systems that are expected to be available commercially. Also included is a series of presentations from Federal Government organizations and research institutions covering their mass storage requirements for the 1990's.

  8. Prospects for high-precision pulsar timing with the new Effelsberg PSRIX backend

    NASA Astrophysics Data System (ADS)

    Lazarus, P.; Karuppusamy, R.; Graikou, E.; Caballero, R. N.; Champion, D. J.; Lee, K. J.; Verbiest, J. P. W.; Kramer, M.

    2016-05-01

    The PSRIX backend is the primary pulsar timing instrument of the Effelsberg 100 m radio telescope since early 2011. This new ROACH-based system enables bandwidths up to 500 MHz to be recorded, significantly more than what was possible with its predecessor, the Effelsberg-Berkeley Pulsar Processor (EBPP). We review the first four years of PSRIX timing data for 33 pulsars collected as part of the monthly European Pulsar Timing Array (EPTA) observations. We describe the automated data analysis pipeline, COASTGUARD, that we developed to reduce these observations. We also introduce TOASTER, the EPTA timing data base, used to store timing results, processing information and observation metadata. Using these new tools, we measure the phase-averaged flux densities at 1.4 GHz of all 33 pulsars. For seven of these pulsars, our flux density measurements are the first values ever reported. For the other 26 pulsars, we compare our flux density measurements with previously published values. By comparing PSRIX data with EBPP data, we find an improvement of ˜2-5 times in signal-to-noise ratio, which translates to an increase of ˜2-5 times in pulse time-of-arrival (TOA) precision. We show that such an improvement in TOA precision will improve the sensitivity to the stochastic gravitational wave background. Finally, we showcase the flexibility of the new PSRIX backend by observing several millisecond-period pulsars (MSPs) at 5 and 9 GHz. Motivated by our detections, we discuss the potential for complementing existing pulsar timing array data sets with MSP monitoring campaigns at these higher frequencies.

  9. Analysis of cache for streaming tape drive

    NASA Technical Reports Server (NTRS)

    Chinnaswamy, V.

    1993-01-01

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  10. Krytox Lubrication Tape Study. [fluorinated lubricating oil for video tape recorders

    NASA Technical Reports Server (NTRS)

    Lee, F.

    1978-01-01

    The use of Krytox, a fluorinated oil, as a tape surface lubricant was studied for a wideband video tape recorder. In spite of the 5 to 1 head wear reduction credited to the surface lubricant, the resultant head life fell short of the 1500 hour goal.

  11. Digital tape unit test facility software

    NASA Technical Reports Server (NTRS)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  12. SETIBURST: A Robotic, Commensal, Realtime Multi-science Backend for the Arecibo Telescope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chennamangalam, Jayanth; Karastergiou, Aris; Williams, Christopher

    Radio astronomy has traditionally depended on observatories allocating time to observers for exclusive use of their telescopes. The disadvantage of this scheme is that the data thus collected is rarely used for other astronomy applications, and in many cases, is unsuitable. For example, properly calibrated pulsar search data can, with some reduction, be used for spectral line surveys. A backend that supports plugging in multiple applications to a telescope to perform commensal data analysis will vastly increase the science throughput of the facility. In this paper, we present “SETIBURST,” a robotic, commensal, realtime multi-science backend for the 305 m Arecibomore » Telescope. The system uses the 1.4 GHz, seven-beam Arecibo L -band Feed Array (ALFA) receiver whenever it is operated. SETIBURST currently supports two applications: SERENDIP VI, a SETI spectrometer that is conducting a search for signs of technological life, and ALFABURST, a fast transient search system that is conducting a survey of fast radio bursts (FRBs). Based on the FRB event rate and the expected usage of ALFA, we expect 0–5 FRB detections over the coming year. SETIBURST also provides the option of plugging in more applications. We outline the motivation for our instrumentation scheme and the scientific motivation of the two surveys, along with their descriptions and related discussions.« less

  13. SETIBURST: A Robotic, Commensal, Realtime Multi-science Backend for the Arecibo Telescope

    NASA Astrophysics Data System (ADS)

    Chennamangalam, Jayanth; MacMahon, David; Cobb, Jeff; Karastergiou, Aris; Siemion, Andrew P. V.; Rajwade, Kaustubh; Armour, Wes; Gajjar, Vishal; Lorimer, Duncan R.; McLaughlin, Maura A.; Werthimer, Dan; Williams, Christopher

    2017-02-01

    Radio astronomy has traditionally depended on observatories allocating time to observers for exclusive use of their telescopes. The disadvantage of this scheme is that the data thus collected is rarely used for other astronomy applications, and in many cases, is unsuitable. For example, properly calibrated pulsar search data can, with some reduction, be used for spectral line surveys. A backend that supports plugging in multiple applications to a telescope to perform commensal data analysis will vastly increase the science throughput of the facility. In this paper, we present “SETIBURST,” a robotic, commensal, realtime multi-science backend for the 305 m Arecibo Telescope. The system uses the 1.4 GHz, seven-beam Arecibo L-band Feed Array (ALFA) receiver whenever it is operated. SETIBURST currently supports two applications: SERENDIP VI, a SETI spectrometer that is conducting a search for signs of technological life, and ALFABURST, a fast transient search system that is conducting a survey of fast radio bursts (FRBs). Based on the FRB event rate and the expected usage of ALFA, we expect 0-5 FRB detections over the coming year. SETIBURST also provides the option of plugging in more applications. We outline the motivation for our instrumentation scheme and the scientific motivation of the two surveys, along with their descriptions and related discussions.

  14. WPS mediation: An approach to process geospatial data on different computing backends

    NASA Astrophysics Data System (ADS)

    Giuliani, Gregory; Nativi, Stefano; Lehmann, Anthony; Ray, Nicolas

    2012-10-01

    The OGC Web Processing Service (WPS) specification allows generating information by processing distributed geospatial data made available through Spatial Data Infrastructures (SDIs). However, current SDIs have limited analytical capacities and various problems emerge when trying to use them in data and computing-intensive domains such as environmental sciences. These problems are usually not or only partially solvable using single computing resources. Therefore, the Geographic Information (GI) community is trying to benefit from the superior storage and computing capabilities offered by distributed computing (e.g., Grids, Clouds) related methods and technologies. Currently, there is no commonly agreed approach to grid-enable WPS. No implementation allows one to seamlessly execute a geoprocessing calculation following user requirements on different computing backends, ranging from a stand-alone GIS server up to computer clusters and large Grid infrastructures. Considering this issue, this paper presents a proof of concept by mediating different geospatial and Grid software packages, and by proposing an extension of WPS specification through two optional parameters. The applicability of this approach will be demonstrated using a Normalized Difference Vegetation Index (NDVI) mediated WPS process, highlighting benefits, and issues that need to be further investigated to improve performances.

  15. Up-to-date state of storage techniques used for large numerical data files

    NASA Technical Reports Server (NTRS)

    Chlouba, V.

    1975-01-01

    Methods for data storage and output in data banks and memory files are discussed along with a survey of equipment available for this. Topics discussed include magnetic tapes, magnetic disks, Terabit magnetic tape memory, Unicon 690 laser memory, IBM 1360 photostore, microfilm recording equipment, holographic recording, film readers, optical character readers, digital data storage techniques, and photographic recording. The individual types of equipment are summarized in tables giving the basic technical parameters.

  16. A hierarchical storage management (HSM) scheme for cost-effective on-line archival using lossy compression.

    PubMed

    Avrin, D E; Andriole, K P; Yin, L; Gould, R G; Arenson, R L

    2001-03-01

    A hierarchical storage management (HSM) scheme for cost-effective on-line archival of image data using lossy compression is described. This HSM scheme also provides an off-site tape backup mechanism and disaster recovery. The full-resolution image data are viewed originally for primary diagnosis, then losslessly compressed and sent off site to a tape backup archive. In addition, the original data are wavelet lossy compressed (at approximately 25:1 for computed radiography, 10:1 for computed tomography, and 5:1 for magnetic resonance) and stored on a large RAID device for maximum cost-effective, on-line storage and immediate retrieval of images for review and comparison. This HSM scheme provides a solution to 4 problems in image archiving, namely cost-effective on-line storage, disaster recovery of data, off-site tape backup for the legal record, and maximum intermediate storage and retrieval through the use of on-site lossy compression.

  17. Performance of preformed plastic tapes.

    DOT National Transportation Integrated Search

    1982-01-01

    This study was initiated to investigate the overall performance of preformed pavement marking tapes with respect to their appearance, durability, and night visibility, and to recommend criteria for the selection of such materials based on their perfo...

  18. Quick-release medical tape

    PubMed Central

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M.

    2012-01-01

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive–skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes. PMID:23112196

  19. Influence of gamma ray irradiation on thermal conductivity of bismaleimide-triazine-based insulation tape at cryogenic temperature

    NASA Astrophysics Data System (ADS)

    Yang, Y.; Yoshida, M.; Idesaki, A.; Ogitsu, T.

    2018-01-01

    Recent accelerator-based experiments for particle physics require the superconducting magnets that can be operated under high radiation environment. An electrical insulation tape, which is composed of polyimide film and a boron free glass fabric pre-impregnated with epoxy resin blended with bismaleimide-triazine resin, is developed to enhance the radiation tolerance for superconducting magnets. Since the thermal conductivity of insulation tape is one of key parameters that affects the coil temperature during the operation, the influence of gamma-ray irradiation on the thermal conductivity of the insulation tape is investigated with a maximum dose of 5 MGy. The thermal conductivity is measured at cryogenic temperature from 5 K to 20 K cooled by a Gifford-McMahon cryocooler. By comparing the thermal conductivity before and after the gamma ray irradiation, no significant degradation on the thermal conductivity has been observed.

  20. Tracer sensitive tapes

    NASA Technical Reports Server (NTRS)

    Burrows, W. H.; Burrows, W. H.

    1971-01-01

    A leak detection system has been developed, consisting of a tape that can be wrapped around possible leak sites on a system pressurized with air or gaseous nitrogen. Carbon monoxide, at a level of 100 to 1000 parts per million is used as a trace gas in the pressurized system. The sensitive element of the tape is palladium chloride supported on specially prepared silica gel and specially dried. At a CO level of 100 ppm and a leak rate of 10-20 ml/hr, discoloration of the sensitive element is observed in 1.5 to 3 min. The tape and trace gas are compatible with aerospace hardware, safe to handle, and economically reasonable to produce and handle.

  1. The mass storage testing laboratory at GSFC

    NASA Technical Reports Server (NTRS)

    Venkataraman, Ravi; Williams, Joel; Michaud, David; Gu, Heng; Kalluri, Atri; Hariharan, P. C.; Kobler, Ben; Behnke, Jeanne; Peavey, Bernard

    1998-01-01

    Industry-wide benchmarks exist for measuring the performance of processors (SPECmarks), and of database systems (Transaction Processing Council). Despite storage having become the dominant item in computing and IT (Information Technology) budgets, no such common benchmark is available in the mass storage field. Vendors and consultants provide services and tools for capacity planning and sizing, but these do not account for the complete set of metrics needed in today's archives. The availability of automated tape libraries, high-capacity RAID systems, and high- bandwidth interconnectivity between processor and peripherals has led to demands for services which traditional file systems cannot provide. File Storage and Management Systems (FSMS), which began to be marketed in the late 80's, have helped to some extent with large tape libraries, but their use has introduced additional parameters affecting performance. The aim of the Mass Storage Test Laboratory (MSTL) at Goddard Space Flight Center is to develop a test suite that includes not only a comprehensive check list to document a mass storage environment but also benchmark code. Benchmark code is being tested which will provide measurements for both baseline systems, i.e. applications interacting with peripherals through the operating system services, and for combinations involving an FSMS. The benchmarks are written in C, and are easily portable. They are initially being aimed at the UNIX Open Systems world. Measurements are being made using a Sun Ultra 170 Sparc with 256MB memory running Solaris 2.5.1 with the following configuration: 4mm tape stacker on SCSI 2 Fast/Wide; 4GB disk device on SCSI 2 Fast/Wide; and Sony Petaserve on Fast/Wide differential SCSI 2.

  2. Simulation and analysis of tape spring for deployed space structures

    NASA Astrophysics Data System (ADS)

    Chang, Wei; Cao, DongJing; Lian, MinLong

    2018-03-01

    The tape spring belongs to the configuration of ringent cylinder shell, and the mechanical properties of the structure are significantly affected by the change of geometrical parameters. There are few studies on the influence of geometrical parameters on the mechanical properties of the tape spring. The bending process of the single tape spring was simulated based on simulation software. The variations of critical moment, unfolding moment, and maximum strain energy in the bending process were investigated, and the effects of different radius angles of section and thickness and length on driving capability of the simple tape spring was studied by using these parameters. Results show that the driving capability and resisting disturbance capacity grow with the increase of radius angle of section in the bending process of the single tape spring. On the other hand, these capabilities decrease with increasing length of the single tape spring. In the end, the driving capability and resisting disturbance capacity grow with the increase of thickness in the bending process of the single tape spring. The research has a certain reference value for improving the kinematic accuracy and reliability of deployable structures.

  3. Effect of tape recording on perturbation measures.

    PubMed

    Jiang, J; Lin, E; Hanson, D G

    1998-10-01

    Tape recorders have been shown to affect measures of voice perturbation. Few studies, however, have been conducted to quantitatively justify the use or exclusion of certain types of recorders in voice perturbation studies. This study used sinusoidal and triangular waves and synthesized vowels to compare perturbation measures extracted from directly digitized signals with those recorded and played back through various tape recorders, including 3 models of digital audio tape recorders, 2 models of analog audio cassette tape recorders, and 2 models of video tape recorders. Signal contamination for frequency perturbation values was found to be consistently minimal with digital recorders (percent jitter = 0.01%-0.02%), mildly increased with video recorders (0.05%-0.10%), moderately increased with a high-quality analog audio cassette tape recorder (0.15%), and most prominent with a low-quality analog audio cassette tape recorder (0.24%). Recorder effect on amplitude perturbation measures was lowest in digital recorders (percent shimmer = 0.09%-0.20%), mildly to moderately increased in video recorders and a high-quality analog audio cassette tape recorder (0.25%-0.45%), and most prominent in a low-quality analog audio cassette tape recorder (0.98%). The effect of cassette tape material, length of spooled tape, and duration of analysis were also tested and are discussed.

  4. Enhancing contrast of fingerprints on plastic tape.

    PubMed

    Steele, Charles A; Ball, Mikki S

    2003-11-01

    Many of the currently available fingerprinting methods have limited ability to visualize fingerprints on plastic tape without expensive equipment or significant handling of the sample. This is especially true for visualizing fingerprints on black electrical tape. This study sought a hands-off method to produce easy visualization of fingerprints on different types of plastic tape, including black electrical tape, without the need for expensive equipment. The methods selected were to sublime disperse dyes into the tape, both with and without the fuming of cyanoacrylate, everywhere except for where the fingerprint was applied. The resulting color contrasts provided enough differentiation to visualize fingerprints on plastic tape under ambient light. Sequential fuming with cyanoacrylate followed by disperse dyes provided the best visualizations on all tapes, and cyanoacrylate followed by disperse yellow 211 clearly visualized fingerprints on black electrical tape.

  5. EROS to universal tape conversion processor

    NASA Technical Reports Server (NTRS)

    Obrien, S. O. (Principal Investigator)

    1980-01-01

    The function of the EROS processor is to allow a user to select a specific area from a full frame LANDSAT image which is written on tape in the EROS format. The area of interest is read from the EROS formatted tape and converted to the JSC Universal format and written onto another tape. This tape can then be read by the IMDACS processing system and normal analysis can be performed.

  6. Evaluation of the Huawei UDS cloud storage system for CERN specific data

    NASA Astrophysics Data System (ADS)

    Zotes Resines, M.; Heikkila, S. S.; Duellmann, D.; Adde, G.; Toebbicke, R.; Hughes, J.; Wang, L.

    2014-06-01

    Cloud storage is an emerging architecture aiming to provide increased scalability and access performance, compared to more traditional solutions. CERN is evaluating this promise using Huawei UDS and OpenStack SWIFT storage deployments, focusing on the needs of high-energy physics. Both deployed setups implement S3, one of the protocols that are emerging as a standard in the cloud storage market. A set of client machines is used to generate I/O load patterns to evaluate the storage system performance. The presented read and write test results indicate scalability both in metadata and data perspectives. Futher the Huawei UDS cloud storage is shown to be able to recover from a major failure of losing 16 disks. Both cloud storages are finally demonstrated to function as back-end storage systems to a filesystem, which is used to deliver high energy physics software.

  7. Storage resource manager

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perelmutov, T.; Bakken, J.; Petravick, D.

    Storage Resource Managers (SRMs) are middleware components whose function is to provide dynamic space allocation and file management on shared storage components on the Grid[1,2]. SRMs support protocol negotiation and reliable replication mechanism. The SRM standard supports independent SRM implementations, allowing for a uniform access to heterogeneous storage elements. SRMs allow site-specific policies at each location. Resource Reservations made through SRMs have limited lifetimes and allow for automatic collection of unused resources thus preventing clogging of storage systems with ''orphan'' files. At Fermilab, data handling systems use the SRM management interface to the dCache Distributed Disk Cache [5,6] and themore » Enstore Tape Storage System [15] as key components to satisfy current and future user requests [4]. The SAM project offers the SRM interface for its internal caches as well.« less

  8. NSSDC Conference on Mass Storage Systems and Technologies for Space and Earth Science Applications, volume 2

    NASA Technical Reports Server (NTRS)

    Kobler, Ben (Editor); Hariharan, P. C. (Editor); Blasso, L. G. (Editor)

    1992-01-01

    This report contains copies of nearly all of the technical papers and viewgraphs presented at the NSSDC Conference on Mass Storage Systems and Technologies for Space and Earth Science Application. This conference served as a broad forum for the discussion of a number of important issues in the field of mass storage systems. Topics include the following: magnetic disk and tape technologies; optical disk and tape; software storage and file management systems; and experiences with the use of a large, distributed storage system. The technical presentations describe, among other things, integrated mass storage systems that are expected to be available commercially. Also included is a series of presentations from Federal Government organizations and research institutions covering their mass storage requirements for the 1990's.

  9. NSSDC Conference on Mass Storage Systems and Technologies for Space and Earth Science Applications, volume 3

    NASA Technical Reports Server (NTRS)

    Kobler, Ben (Editor); Hariharan, P. C. (Editor); Blasso, L. G. (Editor)

    1992-01-01

    This report contains copies of nearly all of the technical papers and viewgraphs presented at the National Space Science Data Center (NSSDC) Conference on Mass Storage Systems and Technologies for Space and Earth Science Applications. This conference served as a broad forum for the discussion of a number of important issues in the field of mass storage systems. Topics include magnetic disk and tape technologies, optical disk and tape, software storage and file management systems, and experiences with the use of a large, distributed storage system. The technical presentations describe, among other things, integrated mass storage systems that are expected to be available commercially. Also included is a series of presentations from Federal Government organizations and research institutions covering their mass storage requirements for the 1990s.

  10. A computer-based time study system for timber harvesting operations

    Treesearch

    Jingxin Wang; Joe McNeel; John Baumgras

    2003-01-01

    A computer-based time study system was developed for timber harvesting operations. Object-oriented techniques were used to model and design the system. The front-end of the time study system resides on the MS Windows CE and the back-end is supported by MS Access. The system consists of three major components: a handheld system, data transfer interface, and data storage...

  11. Prototype of the novel CAMEA concept—A backend for neutron spectrometers

    NASA Astrophysics Data System (ADS)

    Markó, Márton; Groitl, Felix; Birk, Jonas Okkels; Freeman, Paul Gregory; Lefmann, Kim; Christensen, Niels Bech; Niedermayer, Christof; Jurányi, Fanni; Lass, Jakob; Hansen, Allan; Rønnow, Henrik M.

    2018-01-01

    The continuous angle multiple energy analysis concept is a backend for both time-of-flight and analyzer-based neutron spectrometers optimized for neutron spectroscopy with highly efficient mapping in the horizontal scattering plane. The design employs a series of several upward scattering analyzer arcs placed behind each other, which are set to different final energies allowing a wide angular coverage with multiple energies recorded simultaneously. For validation of the concept and the model calculations, a prototype was installed at the Swiss neutron source SINQ, Paul Scherrer Institut. The design of the prototype, alignment and calibration procedures, experimental results of background measurements, and proof-of-concept inelastic measurements on LiHoF4 and h-YMnO3 are presented here.

  12. An analysis of image storage systems for scalable training of deep neural networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lim, Seung-Hwan; Young, Steven R; Patton, Robert M

    This study presents a principled empirical evaluation of image storage systems for training deep neural networks. We employ the Caffe deep learning framework to train neural network models for three different data sets, MNIST, CIFAR-10, and ImageNet. While training the models, we evaluate five different options to retrieve training image data: (1) PNG-formatted image files on local file system; (2) pushing pixel arrays from image files into a single HDF5 file on local file system; (3) in-memory arrays to hold the pixel arrays in Python and C++; (4) loading the training data into LevelDB, a log-structured merge tree based key-valuemore » storage; and (5) loading the training data into LMDB, a B+tree based key-value storage. The experimental results quantitatively highlight the disadvantage of using normal image files on local file systems to train deep neural networks and demonstrate reliable performance with key-value storage based storage systems. When training a model on the ImageNet dataset, the image file option was more than 17 times slower than the key-value storage option. Along with measurements on training time, this study provides in-depth analysis on the cause of performance advantages/disadvantages of each back-end to train deep neural networks. We envision the provided measurements and analysis will shed light on the optimal way to architect systems for training neural networks in a scalable manner.« less

  13. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, Eric B.; Muller, Albert C.

    1984-01-01

    A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

  14. Electron trapping data storage system and applications

    NASA Technical Reports Server (NTRS)

    Brower, Daniel; Earman, Allen; Chaffin, M. H.

    1993-01-01

    The advent of digital information storage and retrieval has led to explosive growth in data transmission techniques, data compression alternatives, and the need for high capacity random access data storage. Advances in data storage technologies are limiting the utilization of digitally based systems. New storage technologies will be required which can provide higher data capacities and faster transfer rates in a more compact format. Magnetic disk/tape and current optical data storage technologies do not provide these higher performance requirements for all digital data applications. A new technology developed at the Optex Corporation out-performs all other existing data storage technologies. The Electron Trapping Optical Memory (ETOM) media is capable of storing as much as 14 gigabytes of uncompressed data on a single, double-sided 54 inch disk with a data transfer rate of up to 12 megabits per second. The disk is removable, compact, lightweight, environmentally stable, and robust. Since the Write/Read/Erase (W/R/E) processes are carried out 100 percent photonically, no heating of the recording media is required. Therefore, the storage media suffers no deleterious effects from repeated Write/Read/Erase cycling.

  15. Kinematics of Tape Recording.

    ERIC Educational Resources Information Center

    Coleman, J. J.

    1982-01-01

    Describes mathematics of the nonliner relationships between a constant-speed, capstan-driven magnetic tape transport mechanism and a constant-angular-velocity take-up reel. The relationship, derived from the sum of a partial, serves in recognition of a finite tape. Thickness can serve as an example of rotational kinematics. (Author/SK)

  16. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  17. Barium titanate tape properties for MLCC application using different binder systems

    NASA Astrophysics Data System (ADS)

    Yoon, Dang-Hyok

    Most of multilayer ceramic capacitor (MLCC) industries are currently using solvent-based slip systems, although water-based slips have been receiving increasing attention due to reduced health and environmental hazards. The current work focuses on two main fields to meet the challenges in MLCC processing in aqueous media. One is the comparison between water- and solvent-based slip systems using design of experiments (DOE). The other is the understanding of Ba2+ ion leaching behavior in water and its effect on tape properties. For the first part, twenty four kinds of BaTiO3 slips were investigated using three different binder systems: one solvent-based, and two water-based systems. Tape casting, sintering and characterization were conducted. Slip viscosity and tape strength of the green tape depended significantly on the binder type. It was possible to achieve a higher green density for water-based system than that for a solvent-based one. Most of the green body properties from solvent-based system depended on the ceramic powder. On the other hand, the dispersant was the most significant factor for the green body properties of two water-based systems. Sintered properties such as microstructure and dielectric permittivity for three systems depended significantly on the type of ceramic powder. An optimization was performed for each system by means of a scorecard. By choosing the optimum condition, comparable results were drawn for the water-based system compared to a solvent-based one for MLCC application. For the second part, the amount of Ba2+ ion leaching from BaTiO3 in water was determined by an EDTA titration method. The greater extent and the faster rate of Ba2+ leaching were found at the lower solution pH. The excess free barium ions expressed by means of the Ba/Ti ratio adversely affected most tape properties. To passivate BaTiO 3 surface from Ba2+ ion leaching in water, passivation agent layer (PAL) was formed by drying the slurry after adding a commercial

  18. FGGE/ERBZ tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

  19. Source-Constrained Recall: Front-End and Back-End Control of Retrieval Quality

    ERIC Educational Resources Information Center

    Halamish, Vered; Goldsmith, Morris; Jacoby, Larry L.

    2012-01-01

    Research on the strategic regulation of memory accuracy has focused primarily on monitoring and control processes used to edit out incorrect information after it is retrieved (back-end control). Recent studies, however, suggest that rememberers also enhance accuracy by preventing the retrieval of incorrect information in the first place (front-end…

  20. Torsional Properties of TiNi Shape Memory Alloy Tape for Rotary Actuator

    NASA Astrophysics Data System (ADS)

    Takeda, K.; Tobushi, H.; Mitsui, K.; Nishimura, Y.; Miyamoto, K.

    2012-12-01

    In order to develop novel shape memory actuators, the torsional deformation of a shape memory alloy (SMA) tape and the actuator models driven by the tape were investigated. The results obtained can be summarized as follows. In the SMA tape subjected to torsion, the martensitic transformation appears along both edges of the tape due to elongation of these elements and grows to the central part. The fatigue life in both the pulsating torsion and alternating torsion is expressed by the unified relationship of the dissipated work in each cycle. Based on an opening and closing door model and a solar-powered active blind model, the two-way rotary driving actuator with a small and simple mechanism can be developed by using torsion of the SMA tape.

  1. FGGE/ERBM tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/ERBM tape contains 27 ERB parameters which are extracted and reformatted from the Nimbus-7 ERB-MATRIX tape. There are four types of files on a FGGE/ERBM tape: a test file; tape-header file which describes the data set characteristics and the contents of the tape; a grid-descriptor file which contains the information of the ERB scanning channel target number and their associated latitude limits and longitude intervals; and one or more data files. A single end-of-file (EOF) tape mark is written after each file, and two EOF marks are written after the last data file on the tape.

  2. Fabrication of Polyimide-Matrix/Carbon and Boron-Fiber Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Treasure, Monte; Shahood, Thomas W.

    2007-01-01

    The term HYCARB denotes a hybrid composite of polyimide matrices reinforced with carbon and boron fibers. HYCARB and an improved process for fabricating dry HYCARB tapes have been invented in a continuing effort to develop lightweight, strong composite materials for aerospace vehicles. Like other composite tapes in this line of development, HYCARB tapes are intended to be used to build up laminated structures having possibly complex shapes by means of automated tow placement (ATP) - a process in which a computer-controlled multiaxis machine lays down prepreg tape or tows. The special significance of the present process for making dry HYCARB for ATP is that it contributes to the reduction of the overall cost of manufacturing boron-reinforced composite-material structures while making it possible to realize increased compression strengths. The present process for making HYCARB tapes incorporates a "wet to dry" process developed previously at Langley Research Center. In the "wet to dry" process, a flattened bundle of carbon fiber tows, pulled along a continuous production line between pairs of rollers, is impregnated with a solution of a poly(amide acid) in N-methyl-2-pyrrolidinone (NMP), then most of the NMP is removed by evaporation in hot air. In the present case, the polyamide acid is, more specifically, that of LaRC. IAX (or equivalent) thermoplastic polyimide, and the fibers are, more specifically, Manganite IM7 (or equivalent) polyacrylonitrile- based carbon filaments that have a diameter of 5.2 m and are supplied in 12,000-filament tows. The present process stands in contrast to a prior process in which HYCARB tape was made by pressing boron fibers into the face of a wet carbon-fiber/ poly(amide acid) prepreg tape . that is, a prepreg tape from which the NMP solvent had not been removed. In the present process, one or more layer(s) of side-by-side boron fibers are pressed between dry prepreg tapes that have been prepared by the aforementioned gwet to dry h

  3. Caught (Unfortunately) on Tape

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  4. Modeling and simulation of Cu diffusion and drift in porous CMOS backend dielectrics

    NASA Astrophysics Data System (ADS)

    Ali, R.; Fan, Y.; King, S.; Orlowski, M.

    2018-06-01

    With the advent of porous dielectrics, Cu drift-diffusion reliability issues in CMOS backend have only been exacerbated. In this regard, a modeling and simulation study of Cu atom/ion drift-diffusion in porous dielectrics is presented to assess the backend reliability and to explore conditions for a reliable Resistive Random Access Memory (RRAM) operation. The numerical computation, using elementary jump frequencies for a random walk in 2D and 3D, is based on an extended adjacency tensor concept. It is shown that Cu diffusion and drift transport are affected as much by the level of porosity as by the pore morphology. Allowance is made for different rates of Cu dissolution into the dielectric and for Cu absorption and transport at and on the inner walls of the pores. Most of the complex phenomena of the drift-diffusion transport in porous media can be understood in terms of local lateral and vertical gradients and the degree of their perturbation caused by the presence of pores in the transport domain. The impact of pore morphology, related to the concept of tortuosity, is discussed in terms of "channeling" and "trapping" effects. The simulations are calibrated to experimental results of porous SiCOH layers of 25 nm thickness, sandwiched between Cu and Pt(W) electrodes with experimental porosity levels of 0%, 8%, 12%, and 25%. We find that porous SICOH is more immune to Cu+ drift at 300 K than non-porous SICOH.

  5. Effectiveness of functional ankle taping for judo athletes: a comparison between judo bandaging and taping.

    PubMed Central

    Yamamoto, T; Kigawa, A; Xu, T

    1993-01-01

    This study was conducted to compare the effectiveness of the traditional method of ankle bandaging and the new method of ankle taping for judo athletes in Japan, and to introduce a functionally effective taping method for judo players. Four university judo athletes with ankle instability were selected to undertake radiography of the ankles before and after exercise, with bandaging at one time and taping at the other. Talar tilt (TT) angles were measured in order to compare the ankle-supporting effects. The results showed that the old ankle bandaging method had no role in eliminating the talar tilt during judo practice. In contrast, the new taping method was more effective in eliminating the talar tilt and supporting the involved ankles both mechanically and functionally. Images Figure 1 Figure 2 Figure 3 PMID:8358580

  6. A system approach to archival storage

    NASA Technical Reports Server (NTRS)

    Corcoran, John W.

    1991-01-01

    The introduction and viewgraphs of a discussion on a system approach to archival storage presented at the National Space Science Data Center (NSSDC) Mass Storage Workshop is included. The use of D-2 iron particles for archival storage is discussed along with how acceleration factors relating short-term tests to archival life times can be justified. Ampex Recording Systems is transferring D-2 video technology to data storage applications, and encountering concerns about corrosion. To protect the D-2 standard, Battelle tests were done on all four tapes in the Class 2 environment. Error rates were measured before and after the test on both exposed and control groups.

  7. Robo-line storage: Low latency, high capacity storage systems over geographically distributed networks

    NASA Technical Reports Server (NTRS)

    Katz, Randy H.; Anderson, Thomas E.; Ousterhout, John K.; Patterson, David A.

    1991-01-01

    Rapid advances in high performance computing are making possible more complete and accurate computer-based modeling of complex physical phenomena, such as weather front interactions, dynamics of chemical reactions, numerical aerodynamic analysis of airframes, and ocean-land-atmosphere interactions. Many of these 'grand challenge' applications are as demanding of the underlying storage system, in terms of their capacity and bandwidth requirements, as they are on the computational power of the processor. A global view of the Earth's ocean chlorophyll and land vegetation requires over 2 terabytes of raw satellite image data. In this paper, we describe our planned research program in high capacity, high bandwidth storage systems. The project has four overall goals. First, we will examine new methods for high capacity storage systems, made possible by low cost, small form factor magnetic and optical tape systems. Second, access to the storage system will be low latency and high bandwidth. To achieve this, we must interleave data transfer at all levels of the storage system, including devices, controllers, servers, and communications links. Latency will be reduced by extensive caching throughout the storage hierarchy. Third, we will provide effective management of a storage hierarchy, extending the techniques already developed for the Log Structured File System. Finally, we will construct a protototype high capacity file server, suitable for use on the National Research and Education Network (NREN). Such research must be a Cornerstone of any coherent program in high performance computing and communications.

  8. Status of emerging standards for removable computer storage media and related contributions of NIST

    NASA Technical Reports Server (NTRS)

    Podio, Fernando L.

    1992-01-01

    Standards for removable computer storage media are needed so that users may reliably interchange data both within and among various computer installations. Furthermore, media interchange standards support competition in industry and prevent sole-source lock-in. NIST participates in magnetic tape and optical disk standards development through Technical Committees X3B5, Digital Magnetic Tapes, X3B11, Optical Digital Data Disk, and the Joint Technical Commission on Data Permanence. NIST also participates in other relevant national and international standards committees for removable computer storage media. Industry standards for digital magnetic tapes require the use of Standard Reference Materials (SRM's) developed and maintained by NIST. In addition, NIST has been studying care and handling procedures required for digital magnetic tapes. NIST has developed a methodology for determining the life expectancy of optical disks. NIST is developing care and handling procedures for optical digital data disks and is involved in a program to investigate error reporting capabilities of optical disk drives. This presentation reflects the status of emerging magnetic tape and optical disk standards, as well as NIST's contributions in support of these standards.

  9. High density tape/head interface study

    NASA Technical Reports Server (NTRS)

    Csengery, L. C.

    1983-01-01

    The high energy (H sub c approximately or = to 650 oersteds) tapes and high track density (84 tracks per inch) heads investigated had, as its goal, the definition of optimum combinations of head and tape, including the control required of their interfacial dynamics that would enable the manufacture of high rate (150 Mbps) digital tape recorders for unattended space flight.

  10. High-performance mass storage system for workstations

    NASA Technical Reports Server (NTRS)

    Chiang, T.; Tang, Y.; Gupta, L.; Cooperman, S.

    1993-01-01

    media, and the tapes are used as backup media. The storage system is managed by the IEEE mass storage reference model-based UniTree software package. UniTree software will keep track of all files in the system, will automatically migrate the lesser used files to archive media, and will stage the files when needed by the system. The user can access the files without knowledge of their physical location. The high-performance mass storage system developed by Loral AeroSys will significantly boost the system I/O performance and reduce the overall data storage cost. This storage system provides a highly flexible and cost-effective architecture for a variety of applications (e.g., realtime data acquisition with a signal and image processing requirement, long-term data archiving and distribution, and image analysis and enhancement).

  11. ProjectQ: Compiling quantum programs for various backends

    NASA Astrophysics Data System (ADS)

    Haener, Thomas; Steiger, Damian S.; Troyer, Matthias

    In order to control quantum computers beyond the current generation, a high level quantum programming language and optimizing compilers will be essential. Therefore, we have developed ProjectQ - an open source software framework to facilitate implementing and running quantum algorithms both in software and on actual quantum hardware. Here, we introduce the backends available in ProjectQ. This includes a high-performance simulator and emulator to test and debug quantum algorithms, tools for resource estimation, and interfaces to several small-scale quantum devices. We demonstrate the workings of the framework and show how easily it can be further extended to control upcoming quantum hardware.

  12. A prospective randomized blister prevention trial assessing paper tape in endurance distances (Pre-TAPED).

    PubMed

    Lipman, Grant S; Ellis, Mark A; Lewis, Erica J; Waite, Brandee L; Lissoway, John; Chan, Garrett K; Krabak, Brian J

    2014-12-01

    Friction foot blisters are a common injury occurring in up to 39% of marathoners, the most common injury in adventure racing, and represent more than 70% of medical visits in multi-stage ultramarathons. The goal of the study was to determine whether paper tape could prevent foot blisters in ultramarathon runners. This prospective randomized trial was undertaken during RacingThePlanet 155-mile (250-km), 7-day self-supported ultramarathons in China, Australia, Egypt, Chile, and Nepal in 2010 and 2011. Paper tape was applied prerace to one randomly selected foot, with the untreated foot acting as the own control. The study end point was development of a hot spot or blister on any location of either foot. One hundred thirty-six participants were enrolled with 90 (66%) having completed data for analysis. There were 36% women, with a mean age of 40 ± 9.4 years (range, 25-40 years) and pack weight of 11 ± 1.8 kg (range, 8-16 kg). All participants developed blisters, with 89% occurring by day 2 and 59% located on the toes. No protective effect was observed by the intervention (47 versus 35; 52% versus 39%; P = .22), with fewer blisters occurring around the tape on the experimental foot than under the tape (23 vs 31; 25.6% versus 34.4%), yet 84% of study participants when queried would choose paper tape for blister prevention in the future. Although paper tape was not found to be significantly protective against blisters, the intervention was well tolerated with high user satisfaction. Copyright © 2014 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  13. Forensic utility of the carbon isotope ratio of PVC tape backings

    NASA Astrophysics Data System (ADS)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  14. Corrosion of metal particle and metal evaporated tapes

    NASA Technical Reports Server (NTRS)

    Speliotis, Dennis E.

    1991-01-01

    Very high coercivity metal particle (MP) and metal evaporated (ME) tapes are being used in 8mm video and digital audio tape applications, and more recently in digital data recording applications. In view of the inherent susceptibility of such media to environmental corrosion, a number of recent studies have addressed their long term stability and archivability. These studies have used an accelerated corrosion test based either on elevated temperature-humidity or polluting gas atmospheres known as Battelle tests. A comparison of the Battelle test results performed at different laboratories reveals a large variation from one location to another, presumably due to incorrect replication of the Battelle condition. Furthermore, when the Battelle tests are performed on enclosed cartridges, it is quite possible that diffusion limits the penetration of the extremely low concentration polluting gaseous species to the inner layers of the tapes during the short time of the accelerated test, whereas in real life these diffusion limitations may not apply. To avoid this uncertainty, the corrosion behavior of commercial 8mm MP and ME tapes when cassettes without their external plastic cases were exposed to 50 deg C and 80 percent RH for 7.5 weeks is investigated.

  15. High current density electropolishing in the preparation of highly smooth substrate tapes for coated conductors

    DOEpatents

    Kreiskott, Sascha [Los Alamos, NM; Matias, Vladimir [Santa Fe, NM; Arendt, Paul N [Los Alamos, NM; Foltyn, Stephen R [Los Alamos, NM; Bronisz, Lawrence E [Los Alamos, NM

    2009-03-31

    A continuous process of forming a highly smooth surface on a metallic tape by passing a metallic tape having an initial roughness through an acid bath contained within a polishing section of an electropolishing unit over a pre-selected period of time, and, passing a mean surface current density of at least 0.18 amperes per square centimeter through the metallic tape during the period of time the metallic tape is in the acid bath whereby the roughness of the metallic tape is reduced. Such a highly smooth metallic tape can serve as a base substrate in subsequent formation of a superconductive coated conductor.

  16. Structural modeling of HTS tapes and cables

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2016-12-01

    Structural finite element analysis (FEA) has been used as an insightful tool to investigate the electromechanical behavior of HTS REBCO tapes and twisted stacked-tape cables under tension, torsion, bending and combined loads. A novel technique was developed for modeling the layered composite structure of the 2G tapes with structural solid-shell elements in ANSYS®. The FEA models produced detailed strain information for the REBCO superconducting layer which was then paired with an analytical model to predict the critical current performance of the 2G HTS tapes under various loads. Two commercially available HTS tapes (SuperPower and SuNAM) under tension, torsion and combined tension-torsion were first analyzed with FEA and compared with available experimental results at 77 K. A sharp critical current degradation was experienced at the yield strength of the tapes under tension and below a 100 mm twist-pitch under torsion. Combined tension-torsion loads had a more gradual degradation of critical current for twist-pitches of 115 mm or shorter but had a negligible difference compared to pure tension for longer twist-pitches. Using the structural solid-shell technique for modeling 2G tapes in ANSYS®, an FEA methodology for simulating full scale three-dimensional HTS stacked-tape cables under pure bending was created. A model of a Twisted-Stacked Tape Cable (TSTC), a configuration first proposed at MIT, was initially developed and then adapted to the slotted-core HTS Cable-In-Conduit Conductor produced by the ENEA laboratory in Italy. The numerical axial strain of the HTS REBCO tapes within the cables as calculated by FEA were found to agree with an analytical model for two cases: perfect-slip (frictionless) and no-slip (bonded). The ENEA CICC model was also compared with recent experimental critical current data at 77 K and was found to match best using a low friction coefficient of 0.02 indicating that the tapes within the cable freely slide with respect to each other

  17. User and group storage management the CMS CERN T2 centre

    NASA Astrophysics Data System (ADS)

    Cerminara, G.; Franzoni, G.; Pfeiffer, A.

    2015-12-01

    A wide range of detector commissioning, calibration and data analysis tasks is carried out by CMS using dedicated storage resources available at the CMS CERN Tier-2 centre. Relying on the functionalities of the EOS disk-only storage technology, the optimal exploitation of the CMS user/group resources has required the introduction of policies for data access management, data protection, cleanup campaigns based on access pattern, and long term tape archival. The resource management has been organised around the definition of working groups and the delegation to an identified responsible of each group composition. In this paper we illustrate the user/group storage management, and the development and operational experience at the CMS CERN Tier-2 centre in the 2012-2015 period.

  18. Micro-Teaching Tapes in Anatomy and Physiology.

    ERIC Educational Resources Information Center

    Stencel, John E.

    1981-01-01

    Outlines the development and use of micro-teaching tapes as a means of supplemental instruction for college anatomy and physiology classes. Tapes include brief explanations of difficult concepts taken from lectures as students listen to cassette tapes and fill in blanks, or answer questions. (DS)

  19. Strategy for robot motion and path planning in robot taping

    NASA Astrophysics Data System (ADS)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  20. Data storage for managing the health enterprise and achieving business continuity.

    PubMed

    Hinegardner, Sam

    2003-01-01

    As organizations move away from a silo mentality to a vision of enterprise-level information, more healthcare IT departments are rejecting the idea of information storage as an isolated, system-by-system solution. IT executives want storage solutions that act as a strategic element of an IT infrastructure, centralizing storage management activities to effectively reduce operational overhead and costs. This article focuses on three areas of enterprise storage: tape, disk, and disaster avoidance.

  1. Visualization of latent fingerprints beneath opaque electrical tapes by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Liu, Kangkang; Zhang, Ning; Meng, Li; Li, Zhigang; Xu, Xiaojing

    2018-03-01

    Electrical tape is found as one type of important trace evidence in crime scene. For example, it is very frequently used to insulate wires in explosive devices in many criminal cases. The fingerprints of the suspects were often left on the adhesive side of the tapes, which can provide very useful clues for the investigation and make it possible for individual identification. The most commonly used method to detect and visualize those latent fingerprints is to peel off each layer of the tapes first and then adopt the chemical methods to develop the fingerprints on the tapes. However, the peeling-off and chemical development process would degrade and contaminate the fingerprints and thus adversely affect the accuracy of identification. Optical coherence tomography (OCT) is a novel forensic imaging modality based on lowcoherence interferometry, which has the advantages of non-destruction, micrometer-level high resolution and crosssectional imaging. In this study, a fiber-based spectral-domain OCT (SD-OCT) system with {6μm resolution was employed to obtain the image of fingerprint sandwiched between two opaque electrical tapes without any pre-processing procedure like peeling-off. Three-dimensional (3D) OCT reconstruction was performed and the subsurface image was produced to visualize the latent fingerprints. The results demonstrate that OCT is a promising tool for recovering the latent fingerprints hidden beneath opaque electrical tape non-destructively and rapidly.

  2. Chemical News Via Audio Tapes: Chemical Industry News

    ERIC Educational Resources Information Center

    Hanford, W. E.; And Others

    1972-01-01

    Tape coverage of internal R&D news now has a broader scope with improved features. A new tape series covering external news of broad interest has been initiated. The use of tape in a Continuing Education Program is discussed as the future plans for expanding the audio tape program. (1 reference) (Author)

  3. Tape-cast sensors and method of making

    DOEpatents

    Mukundan, Rangachary [Santa Fe, NM; Brosha, Eric L [Los Alamos, NM; Garzon, Fernando H [Santa Fe, NM

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  4. Proceedings of the NSSDC Conference on Mass Storage Systems and Technologies for Space and Earth Science Applications

    NASA Technical Reports Server (NTRS)

    Blackwell, Kim; Blasso, Len (Editor); Lipscomb, Ann (Editor)

    1991-01-01

    The proceedings of the National Space Science Data Center Conference on Mass Storage Systems and Technologies for Space and Earth Science Applications held July 23 through 25, 1991 at the NASA/Goddard Space Flight Center are presented. The program includes a keynote address, invited technical papers, and selected technical presentations to provide a broad forum for the discussion of a number of important issues in the field of mass storage systems. Topics include magnetic disk and tape technologies, optical disk and tape, software storage and file management systems, and experiences with the use of a large, distributed storage system. The technical presentations describe integrated mass storage systems that are expected to be available commercially. Also included is a series of presentations from Federal Government organizations and research institutions covering their mass storage requirements for the 1990's.

  5. Wire and Packing Tape Sandwiches

    ERIC Educational Resources Information Center

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  6. Archive Data Tape Library (ADTL)

    DOT National Transportation Integrated Search

    1983-01-01

    The purpose of this directory is to describe the procedures involved in using the ADTL as well as to identify and describe the data tapes contained in the ADTL. This directory provides a listing of the data tapes contained in the ADTL by mode of tran...

  7. Global data bases on distribution, characteristics and methane emission of natural wetlands: Documentation of archived data tape

    NASA Technical Reports Server (NTRS)

    Matthews, Elaine

    1989-01-01

    Global digital data bases on the distribution and environmental characteristics of natural wetlands, compiled by Matthews and Fung (1987), were archived for public use. These data bases were developed to evaluate the role of wetlands in the annual emission of methane from terrestrial sources. Five global 1 deg latitude by 1 deg longitude arrays are included on the archived tape. The arrays are: (1) wetland data source, (2) wetland type, (3) fractional inundation, (4) vegetation type, and (5) soil type. The first three data bases on wetland locations were published by Matthews and Fung (1987). The last two arrays contain ancillary information about these wetland locations: vegetation type is from the data of Matthews (1983) and soil type from the data of Zobler (1986). Users should consult original publications for complete discussion of the data bases. This short paper is designed only to document the tape, and briefly explain the data sets and their initial application to estimating the annual emission of methane from natural wetlands. Included is information about array characteristics such as dimensions, read formats, record lengths, blocksizes and value ranges, and descriptions and translation tables for the individual data bases.

  8. Research on resistance characteristics of YBCO tape under short-time DC large current impact

    NASA Astrophysics Data System (ADS)

    Zhang, Zhifeng; Yang, Jiabin; Qiu, Qingquan; Zhang, Guomin; Lin, Liangzhen

    2017-06-01

    Research of the resistance characteristics of YBCO tape under short-time DC large current impact is the foundation of the developing DC superconducting fault current limiter (SFCL) for voltage source converter-based high voltage direct current system (VSC-HVDC), which is one of the valid approaches to solve the problems of renewable energy integration. SFCL can limit DC short-circuit and enhance the interrupting capabilities of DC circuit breakers. In this paper, under short-time DC large current impacts, the resistance features of naked tape of YBCO tape are studied to find the resistance - temperature change rule and the maximum impact current. The influence of insulation for the resistance - temperature characteristics of YBCO tape is studied by comparison tests with naked tape and insulating tape in 77 K. The influence of operating temperature on the tape is also studied under subcooled liquid nitrogen condition. For the current impact security of YBCO tape, the critical current degradation and top temperature are analyzed and worked as judgment standards. The testing results is helpful for in developing SFCL in VSC-HVDC.

  9. Reel-to-reel substrate tape polishing system

    DOEpatents

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  10. Storage quality-of-service in cloud-based scientific environments: a standardization approach

    NASA Astrophysics Data System (ADS)

    Millar, Paul; Fuhrmann, Patrick; Hardt, Marcus; Ertl, Benjamin; Brzezniak, Maciej

    2017-10-01

    When preparing the Data Management Plan for larger scientific endeavors, PIs have to balance between the most appropriate qualities of storage space along the line of the planned data life-cycle, its price and the available funding. Storage properties can be the media type, implicitly determining access latency and durability of stored data, the number and locality of replicas, as well as available access protocols or authentication mechanisms. Negotiations between the scientific community and the responsible infrastructures generally happen upfront, where the amount of storage space, media types, like: disk, tape and SSD and the foreseeable data life-cycles are negotiated. With the introduction of cloud management platforms, both in computing and storage, resources can be brokered to achieve the best price per unit of a given quality. However, in order to allow the platform orchestrator to programmatically negotiate the most appropriate resources, a standard vocabulary for different properties of resources and a commonly agreed protocol to communicate those, has to be available. In order to agree on a basic vocabulary for storage space properties, the storage infrastructure group in INDIGO-DataCloud together with INDIGO-associated and external scientific groups, created a working group under the umbrella of the Research Data Alliance (RDA). As communication protocol, to query and negotiate storage qualities, the Cloud Data Management Interface (CDMI) has been selected. Necessary extensions to CDMI are defined in regular meetings between INDIGO and the Storage Network Industry Association (SNIA). Furthermore, INDIGO is contributing to the SNIA CDMI reference implementation as the basis for interfacing the various storage systems in INDIGO to the agreed protocol and to provide an official Open-Source skeleton for systems not being maintained by INDIGO partners.

  11. Ubiquitous Graphene Electronics on Scotch Tape

    PubMed Central

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-01-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm−2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V−1 s−1; the transistors still showed high mobility of 1254 (±478) cm2 V−1 s−1 even after they were crumpled. PMID:26220874

  12. Technique for recovery of voice data from heat damaged magnetic tape

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III (Inventor)

    1974-01-01

    A method for conditioning, and thus enabling retrieval of intelligence from, magnetic tapes after damage from heat has caused the tape to wrinkle and curl severely thereby reducing tape width to less than one-half its original size. The damaged tape is superposed on a first piece of splicing tape with the oxide side of the magnetic tape in contact with the adhesive side of the splicing tape and then carefully smoothed by a special tool. A second piece of splicing tape is placed on the backing side of the magnetic tape then the resulting tape stack is trimmed to the original width of the magnetic tape. After the first piece of splicing tape is carefully removed from the oxide side of the damaged magnetic tape, the resulting magnetic tape is then ready to be placed into a recorder for playback.

  13. mz5: Space- and Time-efficient Storage of Mass Spectrometry Data Sets*

    PubMed Central

    Wilhelm, Mathias; Kirchner, Marc; Steen, Judith A. J.; Steen, Hanno

    2012-01-01

    Across a host of MS-driven-omics fields, researchers witness the acquisition of ever increasing amounts of high throughput MS data and face the need for their compact yet efficiently accessible storage. Addressing the need for an open data exchange format, the Proteomics Standards Initiative and the Seattle Proteome Center at the Institute for Systems Biology independently developed the mzData and mzXML formats, respectively. In a subsequent joint effort, they defined an ontology and associated controlled vocabulary that specifies the contents of MS data files, implemented as the newer mzML format. All three formats are based on XML and are thus not particularly efficient in either storage space requirements or read/write speed. This contribution introduces mz5, a complete reimplementation of the mzML ontology that is based on the efficient, industrial strength storage backend HDF5. Compared with the current mzML standard, this strategy yields an average file size reduction to ∼54% and increases linear read and write speeds ∼3–4-fold. The format is implemented as part of the ProteoWizard project and is available under a permissive Apache license. Additional information and download links are available from http://software.steenlab.org/mz5. PMID:21960719

  14. mz5: space- and time-efficient storage of mass spectrometry data sets.

    PubMed

    Wilhelm, Mathias; Kirchner, Marc; Steen, Judith A J; Steen, Hanno

    2012-01-01

    Across a host of MS-driven-omics fields, researchers witness the acquisition of ever increasing amounts of high throughput MS data and face the need for their compact yet efficiently accessible storage. Addressing the need for an open data exchange format, the Proteomics Standards Initiative and the Seattle Proteome Center at the Institute for Systems Biology independently developed the mzData and mzXML formats, respectively. In a subsequent joint effort, they defined an ontology and associated controlled vocabulary that specifies the contents of MS data files, implemented as the newer mzML format. All three formats are based on XML and are thus not particularly efficient in either storage space requirements or read/write speed. This contribution introduces mz5, a complete reimplementation of the mzML ontology that is based on the efficient, industrial strength storage backend HDF5. Compared with the current mzML standard, this strategy yields an average file size reduction to ∼54% and increases linear read and write speeds ∼3-4-fold. The format is implemented as part of the ProteoWizard project and is available under a permissive Apache license. Additional information and download links are available from http://software.steenlab.org/mz5.

  15. Paper Tape Prevents Foot Blisters: A Randomized Prevention Trial Assessing Paper Tape in Endurance Distances II (Pre-TAPED II).

    PubMed

    Lipman, Grant S; Sharp, Louis J; Christensen, Mark; Phillips, Caleb; DiTullio, Alexandra; Dalton, Andrew; Ng, Pearlly; Shangkuan, Jennifer; Shea, Katherine; Krabak, Brian J

    2016-09-01

    To determine whether paper tape prevents foot blisters in multistage ultramarathon runners. Multisite prospective randomized trial. The 2014 250-km (155-mile) 6-stage RacingThePlanet ultramarathons in Jordan, Gobi, Madagascar, and Atacama Deserts. One hundred twenty-eight participants were enrolled: 19 (15%) from the Jordan, 35 (27%) from Gobi, 21 (16%) from Madagascar, and 53 (41%) from the Atacama Desert. The mean age was 39.3 years (22-63) and body mass index was 24.2 kg/m (17.4-35.1), with 31 (22.5%) females. Paper tape was applied to a randomly selected foot before the race, either to participants' blister-prone areas or randomly selected location if there was no blister history, with untaped areas of the same foot used as the control. Development of a blister anywhere on the study foot. One hundred six (83%) participants developed 117 blisters, with treatment success in 98 (77%) runners. Paper tape reduced blisters by 40% (P < 0.01, 95% confidence interval, 28-52) with a number needed to treat of 1.31. Most of the study participants had 1 blister (78%), with most common locations on the toes (n = 58, 50%) and heel (n = 27, 23%), with 94 (80%) blisters occurring by the end of stage 2. Treatment success was associated with earlier stages [odds ratio (OR), 74.9, P < 0.01] and time spent running (OR, 0.66, P = 0.01). Paper tape was found to prevent both the incidence and frequency of foot blisters in runners.

  16. Goddard Conference on Mass Storage Systems and Technologies, volume 2

    NASA Technical Reports Server (NTRS)

    Kobler, Ben (Editor); Hariharan, P. C. (Editor)

    1993-01-01

    Papers and viewgraphs from the conference are presented. Discussion topics include the IEEE Mass Storage System Reference Model, data archiving standards, high-performance storage devices, magnetic and magneto-optic storage systems, magnetic and optical recording technologies, high-performance helical scan recording systems, and low end helical scan tape drives. Additional discussion topics addressed the evolution of the identifiable unit for processing (file, granule, data set, or some similar object) as data ingestion rates increase dramatically, and the present state of the art in mass storage technology.

  17. User's guide and tape specification for ERB 7 DELMAT

    NASA Technical Reports Server (NTRS)

    Ardanuy, P.; Penn, L.

    1985-01-01

    Guidance is provided to the DELMAT user in the areas of purpose, use and limitations of DELMAT tapes and software. The DELMAT tape specifications is also provided. The ERB-7, ERB MAT and tape characteristics applicable to the DELMAT tapes are also summarized.

  18. CERNBox + EOS: end-user storage for science

    NASA Astrophysics Data System (ADS)

    Mascetti, L.; Gonzalez Labrador, H.; Lamanna, M.; Mościcki, JT; Peters, AJ

    2015-12-01

    CERNBox is a cloud synchronisation service for end-users: it allows syncing and sharing files on all major mobile and desktop platforms (Linux, Windows, MacOSX, Android, iOS) aiming to provide offline availability to any data stored in the CERN EOS infrastructure. The successful beta phase of the service confirmed the high demand in the community for an easily accessible cloud storage solution such as CERNBox. Integration of the CERNBox service with the EOS storage back-end is the next step towards providing “sync and share” capabilities for scientific and engineering use-cases. In this report we will present lessons learnt in offering the CERNBox service, key technical aspects of CERNBox/EOS integration and new, emerging usage possibilities. The latter includes the ongoing integration of “sync and share” capabilities with the LHC data analysis tools and transfer services.

  19. An improved magnetic tape recorder

    NASA Technical Reports Server (NTRS)

    Uber, P. W.

    1968-01-01

    Magnetic tape recorder employs a single capstan for simultaneously driving the supply and take-up reels in such a manner that the tape passing between the reels is kept under a predetermined constant tension. This recorder operates with little power and is sufficiently rugged to withstand the severe stresses encountered in high-altitude balloon flight tests.

  20. A study of tape adhesive strength on endotracheal tubes.

    PubMed

    Fenje, N; Steward, D J

    1988-03-01

    A method of assessing the adhesive bond of tapes used to secure endotracheal (ET) tubes is described. Five kinds of tape and six different ET tubes including two silicone rubber, wire-reinforced tubes were tested. There are significant differences in the adhesive strength of different tapes, and in the adhesive bond formed by different ET tube materials. On the Portex clear ET tube, silk tape adhered best (p less than 0.001), followed by waterproof, cloth, dermiclear, and micropore tapes. Adhesive bonding by silk tape was significantly greater (p less than 0.001) for the three clear ET tubes (Portex clear, NCC clear, and Portex ivory) than for the Portex blue and the silicone rubber, wire-reinforced ET tubes. All tapes showed very poor or negligible adhesion to the Sheridan and Portex reinforced ET tubes. Adhesion to these tubes was greatly improved by wrapping them tightly with an "op site" dressing prior to applying tape.

  1. Educational Uses of Cartridge Tapes. Dissemination Document No. 11.

    ERIC Educational Resources Information Center

    Levine, S. Joseph

    Tape cartridges for use by special education teachers are analyzed according to design, effective use, and availability. Basic operating principles of cassette and continuous loop tape cartridges are described and illustrated. Advantages of tape cartridges are indicated, such as the following: the position is saved on tape during student timeouts,…

  2. Methods and systems for fabricating high quality superconducting tapes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majkic, Goran; Selvamanickam, Venkat

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  3. The Broselow and Handtevy Resuscitation Tapes: A Comparison of the Performance of Pediatric Weight Prediction.

    PubMed

    Lowe, Calvin G; Campwala, Rashida T; Ziv, Nurit; Wang, Vincent J

    2016-08-01

    To assess the performance of two pediatric length-based tapes (Broselow and Handtevy) in predicting actual weights of US children. In this descriptive study, weights and lengths of children (newborn through 13 years of age) were extracted from the 2009-2010 National Health and Nutrition Examination Survey (NHANES). Using the measured length ranges for each tape and the NHANES-extracted length data, every case from the study sample was coded into Broselow and Handtevy zones. Mean weights were calculated for each zone and compared to the predicted Broselow and Handtevy weights using measures of bias, precision, and accuracy. A sub-sample was examined that excluded cases with body mass index (BMI)≥95th percentile. Weights of children longer than each tape also were examined. A total of 3,018 cases from the NHANES database met criteria. Although both tapes underestimated children's weight, the Broselow tape outperformed the Handtevy tape across most length ranges in measures of bias, precision, and accuracy of predicted weights relative to actual weights. Accuracy was higher in the Broselow tape for shorter children and in the Handtevy tape for taller children. Among the sub-sample with cases of BMI≥95th percentile removed, performance of the Handtevy tape improved, yet the Broselow tape still performed better. When assessing the weights of children who were longer than either tape, the actual mean weights did not approximate adult weights; although, those exceeding the Handtevy tape were closer. For pediatric weight estimation, the Broselow tape performed better overall than the Handtevy tape and more closely approximated actual weight. Lowe CG , Campwala RT , Ziv N , Wang VJ . The Broselow and Handtevy resuscitation tapes: a comparison of the performance of pediatric weight prediction. Prehosp Disaster Med. 2016;31(4):364-375.

  4. A data colocation grid framework for big data medical image processing: backend design

    NASA Astrophysics Data System (ADS)

    Bao, Shunxing; Huo, Yuankai; Parvathaneni, Prasanna; Plassard, Andrew J.; Bermudez, Camilo; Yao, Yuang; Lyu, Ilwoo; Gokhale, Aniruddha; Landman, Bennett A.

    2018-03-01

    When processing large medical imaging studies, adopting high performance grid computing resources rapidly becomes important. We recently presented a "medical image processing-as-a-service" grid framework that offers promise in utilizing the Apache Hadoop ecosystem and HBase for data colocation by moving computation close to medical image storage. However, the framework has not yet proven to be easy to use in a heterogeneous hardware environment. Furthermore, the system has not yet validated when considering variety of multi-level analysis in medical imaging. Our target design criteria are (1) improving the framework's performance in a heterogeneous cluster, (2) performing population based summary statistics on large datasets, and (3) introducing a table design scheme for rapid NoSQL query. In this paper, we present a heuristic backend interface application program interface (API) design for Hadoop and HBase for Medical Image Processing (HadoopBase-MIP). The API includes: Upload, Retrieve, Remove, Load balancer (for heterogeneous cluster) and MapReduce templates. A dataset summary statistic model is discussed and implemented by MapReduce paradigm. We introduce a HBase table scheme for fast data query to better utilize the MapReduce model. Briefly, 5153 T1 images were retrieved from a university secure, shared web database and used to empirically access an in-house grid with 224 heterogeneous CPU cores. Three empirical experiments results are presented and discussed: (1) load balancer wall-time improvement of 1.5-fold compared with a framework with built-in data allocation strategy, (2) a summary statistic model is empirically verified on grid framework and is compared with the cluster when deployed with a standard Sun Grid Engine (SGE), which reduces 8-fold of wall clock time and 14-fold of resource time, and (3) the proposed HBase table scheme improves MapReduce computation with 7 fold reduction of wall time compare with a naïve scheme when datasets are relative

  5. A Data Colocation Grid Framework for Big Data Medical Image Processing: Backend Design.

    PubMed

    Bao, Shunxing; Huo, Yuankai; Parvathaneni, Prasanna; Plassard, Andrew J; Bermudez, Camilo; Yao, Yuang; Lyu, Ilwoo; Gokhale, Aniruddha; Landman, Bennett A

    2018-03-01

    When processing large medical imaging studies, adopting high performance grid computing resources rapidly becomes important. We recently presented a "medical image processing-as-a-service" grid framework that offers promise in utilizing the Apache Hadoop ecosystem and HBase for data colocation by moving computation close to medical image storage. However, the framework has not yet proven to be easy to use in a heterogeneous hardware environment. Furthermore, the system has not yet validated when considering variety of multi-level analysis in medical imaging. Our target design criteria are (1) improving the framework's performance in a heterogeneous cluster, (2) performing population based summary statistics on large datasets, and (3) introducing a table design scheme for rapid NoSQL query. In this paper, we present a heuristic backend interface application program interface (API) design for Hadoop & HBase for Medical Image Processing (HadoopBase-MIP). The API includes: Upload, Retrieve, Remove, Load balancer (for heterogeneous cluster) and MapReduce templates. A dataset summary statistic model is discussed and implemented by MapReduce paradigm. We introduce a HBase table scheme for fast data query to better utilize the MapReduce model. Briefly, 5153 T1 images were retrieved from a university secure, shared web database and used to empirically access an in-house grid with 224 heterogeneous CPU cores. Three empirical experiments results are presented and discussed: (1) load balancer wall-time improvement of 1.5-fold compared with a framework with built-in data allocation strategy, (2) a summary statistic model is empirically verified on grid framework and is compared with the cluster when deployed with a standard Sun Grid Engine (SGE), which reduces 8-fold of wall clock time and 14-fold of resource time, and (3) the proposed HBase table scheme improves MapReduce computation with 7 fold reduction of wall time compare with a naïve scheme when datasets are relative

  6. A Data Colocation Grid Framework for Big Data Medical Image Processing: Backend Design

    PubMed Central

    Huo, Yuankai; Parvathaneni, Prasanna; Plassard, Andrew J.; Bermudez, Camilo; Yao, Yuang; Lyu, Ilwoo; Gokhale, Aniruddha; Landman, Bennett A.

    2018-01-01

    When processing large medical imaging studies, adopting high performance grid computing resources rapidly becomes important. We recently presented a "medical image processing-as-a-service" grid framework that offers promise in utilizing the Apache Hadoop ecosystem and HBase for data colocation by moving computation close to medical image storage. However, the framework has not yet proven to be easy to use in a heterogeneous hardware environment. Furthermore, the system has not yet validated when considering variety of multi-level analysis in medical imaging. Our target design criteria are (1) improving the framework’s performance in a heterogeneous cluster, (2) performing population based summary statistics on large datasets, and (3) introducing a table design scheme for rapid NoSQL query. In this paper, we present a heuristic backend interface application program interface (API) design for Hadoop & HBase for Medical Image Processing (HadoopBase-MIP). The API includes: Upload, Retrieve, Remove, Load balancer (for heterogeneous cluster) and MapReduce templates. A dataset summary statistic model is discussed and implemented by MapReduce paradigm. We introduce a HBase table scheme for fast data query to better utilize the MapReduce model. Briefly, 5153 T1 images were retrieved from a university secure, shared web database and used to empirically access an in-house grid with 224 heterogeneous CPU cores. Three empirical experiments results are presented and discussed: (1) load balancer wall-time improvement of 1.5-fold compared with a framework with built-in data allocation strategy, (2) a summary statistic model is empirically verified on grid framework and is compared with the cluster when deployed with a standard Sun Grid Engine (SGE), which reduces 8-fold of wall clock time and 14-fold of resource time, and (3) the proposed HBase table scheme improves MapReduce computation with 7 fold reduction of wall time compare with a naïve scheme when datasets are relative

  7. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  8. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  9. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  10. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  11. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Electronic data processing... Electronic data processing tape. (a) Acquisitions of electronic data processing tape by DOE offices shall be in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by...

  12. Cost-effective data storage/archival subsystem for functional PACS

    NASA Astrophysics Data System (ADS)

    Chen, Y. P.; Kim, Yongmin

    1993-09-01

    Not the least of the requirements of a workable PACS is the ability to store and archive vast amounts of information. A medium-size hospital will generate between 1 and 2 TBytes of data annually on a fully functional PACS. A high-speed image transmission network coupled with a comparably high-speed central data storage unit can make local memory and magnetic disks in the PACS workstations less critical and, in an extreme case, unnecessary. Under these circumstances, the capacity and performance of the central data storage subsystem and database is critical in determining the response time at the workstations, thus significantly affecting clinical acceptability. The central data storage subsystem not only needs to provide sufficient capacity to store about ten days worth of images (five days worth of new studies, and on the average, about one comparison study for each new study), but also supplies images to the requesting workstation in a timely fashion. The database must provide fast retrieval responses upon users' requests for images. This paper analyzes both advantages and disadvantages of multiple parallel transfer disks versus RAID disks for short-term central data storage subsystem, as well as optical disk jukebox versus digital recorder tape subsystem for long-term archive. Furthermore, an example high-performance cost-effective storage subsystem which integrates both the RAID disks and high-speed digital tape subsystem as a cost-effective PACS data storage/archival unit are presented.

  13. The growth of the UniTree mass storage system at the NASA Center for Computational Sciences

    NASA Technical Reports Server (NTRS)

    Tarshish, Adina; Salmon, Ellen

    1993-01-01

    In October 1992, the NASA Center for Computational Sciences made its Convex-based UniTree system generally available to users. The ensuing months saw the growth of near-online data from nil to nearly three terabytes, a doubling of the number of CPU's on the facility's Cray YMP (the primary data source for UniTree), and the necessity for an aggressive regimen for repacking sparse tapes and hierarchical 'vaulting' of old files to freestanding tape. Connectivity was enhanced as well with the addition of UltraNet HiPPI. This paper describes the increasing demands placed on the storage system's performance and throughput that resulted from the significant augmentation of compute-server processor power and network speed.

  14. ``Recent experiences and future expectations in data storage technology''

    NASA Astrophysics Data System (ADS)

    Pfister, Jack

    1990-08-01

    For more than 10 years the conventional media for High Energy Physics has been 9 track magnetic tape in various densities. More recently, especially in Europe, the IBM 3480 technology has been adopted while in the United States, especially at Fermilab, 8 mm is being used by the largest experiments as a primary recording media and where possible they are using 8 mm for the production, analysis and distribution of data summary tapes. VHS and Digital Audio tape have recurrently appeared but seem to serve primarily as a back-up storage media. The reasons for what appear to be a radical departure are many. Economics (media and controllers are inexpensive), form factor (two gigabytes per shirt pocket), and convenience (fewer mounts/dismounts per minute) are dominant among the reasons. The traditional data media suppliers seem to have been content to evolve the traditional media at their own pace with only modest enhancements primarily in ``value engineering'' of extant products. Meanwhile, start-up companies providing small system and workstations sought other media both to reduce the price of their offerings and respond to the real need of lower cost back-up for lower cost systems. This happening in a market context where traditional computer systems vendors were leaving the tape market altogether or shifting to ``3480'' technology which has certainly created a climate for reconsideration and change. The newest data storage products, in most cases, are not coming from the technologies developed by the computing industry but by the audio and video industry. Just where these flopticals, opticals, 19 mm tape and the new underlying technologies, such as, ``digital paper'' may fit in the HEP computing requirement picture will be reviewed. What these technologies do for and to HEP will be discussed along with some suggestions for a methodology for tracking and evaluating extant and emerging technologies.

  15. Integration of altitude and airspeed information into a primary flight display via moving-tape formats

    NASA Technical Reports Server (NTRS)

    Abbott, Terence S.; Steinmetz, George G.

    1987-01-01

    A ground-based aircraft simulation study was conducted to determine the effect on pilot performance of replacing the electromechanical altimeter and airspeed indicators with electronically generated representations integrated into the primary flight display via moving-tape (linear moving scale) formats. Several key factors relating to moving-tape formats were examined during the study: tape centering, secondary (trend) information, and tape orientation. The factor of centering refers to whether the tape was centered about the actual airspeed or altitude or about some defined reference value. Tape orientation refers to whether the values represented are arranged in either descending or ascending order. Six pilots participated in this study, with each subject performing 18 runs along a single, known flight profile. Subjective results indicated that the moving-tape formats were generally better than that of the conventional instruments. They also indicated that an actual-centered fixed pointer was preferred to a reference-centered pointer. Performance data for a visual secondary task showed that formats not containing trend information produced better performance; however, no difference was noted in airspeed tracking or altitude tracking performance. Regarding tape orientation, subjective comments indicated that there was lower work load and better performance when the airspeed tape had the high numbers at the top.

  16. Care and Handling of Computer Magnetic Storage Media.

    ERIC Educational Resources Information Center

    Geller, Sidney B.

    Intended for use by data processing installation managers, operating personnel, and technical staff, this publication provides a comprehensive set of care and handling guidelines for the physical/chemical preservation of computer magnetic storage media--principally computer magnetic tapes--and their stored data. Emphasis is placed on media…

  17. Mechanics of Wound Closure: Emerging Tape-Based Wound Closure Technology vs. Traditional Methods.

    PubMed

    Levi, Kemal; Ichiryu, Kei; Kefel, Pelin; Keller, Juergen; Grice, Jon; Belson, Ori; Storne, Eric; Safa, Bauback

    2016-10-12

    To date, there is still a lack of understanding of how wound closure methods perform comparatively under daily bodily movement during the course of healing and how they affect the mechanics of healing. The present study is a first step in understanding and objectively quantifying the gap. The study provides both a new method of metrology for noninvasive evaluation of skin mechanics at the onset of wound healing and an emerging tape-based wound closure technology. The latter shows better performance with respect to commonly used staples and sutures, holding the wound intact and providing uniform mechanical support across the incision.

  18. Graphene-Based Systems for Energy Storage

    NASA Technical Reports Server (NTRS)

    Calle, Carlos I.; Mackey, Paul J.; Johansen, Michael R.; Phillips, James, III; Hogue, Michael; Kaner, Richard B.; El-Kady, Maher

    2016-01-01

    Development of graphene-based energy storage devices based on the Laser Scribe system developed by the University of California Los Angeles. These devices These graphene-based devices store charge on graphene sheets and take advantage of the large accessible surface area of graphene (2,600 m2g) to increase the electrical energy that can be stored. The proposed devices should have the electrical storage capacity of thin-film-ion batteries but with much shorter charge discharge cycle times as well as longer lives The proposed devices will be carbon-based and so will not have the same issues with flammability or toxicity as the standard lithium-based storage cells.

  19. 21 CFR 886.1905 - Nystagmus tape.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1905 Nystagmus tape. (a) Identification. Nystagmus tape is a device that is a long, narrow strip of fabric or other flexible material on which a series of objects are...

  20. Casting Of Multilayer Ceramic Tapes

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1991-01-01

    Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.

  1. Use of adhesive surgical tape with the absorbable continuous subcuticular suture.

    PubMed

    Kolt, Jeremy D

    2003-08-01

    The absorbable continuous subcuticular suture is frequently used to close surgical incisions where the aim is healing by primary intention. A form of adhesive surgical tape is commonly also placed over the wound but this combination closure seems to have its development based on anecdotal, rather than experimental evidence. The present study reviews the scientific literature on the development of sutureless wound closure and presents the current evidence for the use of combination wound closure. Review was undertaken of the medical literature using the PubMed Internet database and cross-referencing major -articles on the subject. The following combinations of key words were searched: skin closure, wound closure, suture technique, sutureless, adhesive tape, op-site, staples, subcuticular suture, complication, infection and scars. Taped closure alone has advantages of lower wound infection rates and greater wound tensile strength, but disadvantages of epidermal reaction, skin edge inversion, doubtful safety and time required for meticulous surgical technique. The use of the continuous absorbable subcuticular suture allows accurate skin edge approximation, which increases the safety margin. The combination closure has a slightly superior cosmetic result to sutureless techniques but no study has been performed to compare the results of combination subcuticular suture and tape, with tape or subcuticular suture alone. There is no evidence in the scientific literature to justify or support the practice of closing a surgical wound with both subcuticular suture and adhesive surgical tape.

  2. Mass Storage System Upgrades at the NASA Center for Computational Sciences

    NASA Technical Reports Server (NTRS)

    Tarshish, Adina; Salmon, Ellen; Macie, Medora; Saletta, Marty

    2000-01-01

    The NASA Center for Computational Sciences (NCCS) provides supercomputing and mass storage services to over 1200 Earth and space scientists. During the past two years, the mass storage system at the NCCS went through a great deal of changes both major and minor. Tape drives, silo control software, and the mass storage software itself were upgraded, and the mass storage platform was upgraded twice. Some of these upgrades were aimed at achieving year-2000 compliance, while others were simply upgrades to newer and better technologies. In this paper we will describe these upgrades.

  3. Playback Station #2 for Cal Net and 5-day-recorder tapes

    USGS Publications Warehouse

    Eaton, Jerry P.

    1978-01-01

    A second system (Playback Station #2) has been set up to play back Cal Net 1" tapes and 5-day-recorder 1/2" tapes. As with the first playback system (Playback Station #1) the tapes are played back on a Bell and Howell VR3700B tape deck and the records are written out on a 16-channel direct-writing Siemens "0scillomink." Separate reproduce heads, tape guides, and tape tension sensor rollers are required for playing back 111 tapes and 1/2" tapes, but changing these tape deck components is a simple task that requires only a few minutes. The discriminators, patch panels, selector switches, filters, time code translators, and signal conditioning circuits for the time code translators and for the tape-speed-compensation signal are all mounted in an equipment rack that stands beside the playback tape deck. Changing playback speeds (15/16 ips or 3 3/4 ips) or changing from Cal Net tapes to 5-day-recorder tapes requires only flipping a few switches and/or changing a few patch cables on the patch panel (in addition to changing the reproduce heads, etc., to change from 1" tape to 1/2" tape). For the Cal Net tapes, the system provides for playback of 9 data channels (680 Hz thru 3060 Hz plus 400 Hz) and 3 time signals (IRIG-E, IRIG-C, and WWVB) at both 15/16 ips (x1 speed) and 3 3/4 ips (x4 speed). Available modes of compensation (using either a 4688 Hz reference or a 3125 Hz reference) are subtractive, capstan, capstan plus subtractive, or no compensation.

  4. Closet to Cloud: The online archiving of tape-based continuous NCSN seismic data from 1993-2005

    NASA Astrophysics Data System (ADS)

    Neuhauser, D. S.; Aranha, M. A.; Kohler, W. M.; Oppenheimer, D.

    2016-12-01

    As earthquake monitoring systems in the 1980s moved from analog to digital recording systems, most seismic networks only archived digital waveforms from detected events due to lack of affordable online digital storage for continuous high-rate (100 sps) data. The Northern California Earthquake Data Center (NCEDC), established in 1991 by UC Berkeley and the USGS Menlo Park, archived 20 sps continuous data and triggerd high-rate from the sparse Berkeley seismic network, but could not afford the online storage for continuous high-rate data from the 300+ stations of the USGS Northern California Seismic Network (NCSN). The discovery of non-volcanic tremor and the use of continuous waveform correlation techniques for detecting repeating earthquakes combined with the increase in disk capacity capacity and significant reduction in disk costs led the Northern California Earthquake Data Center (NCEDC) to begin archiving continuous high-rate waveforms in 2004-2005. The USGS Menlo Park NCSN network had backup tapes of continuous high-rate waveform data since 1993 on the shelf, and the USGS and NCEDC embarked on a project to restore and archive all continuous NCSN data from 1993 through 2005. We will discuss the procedures and problems encountered when reading, transcribing, converting data formats, SEED channel naming, and archiving the 1993-2005 continuous NCSN waveforms. We will also illustrate new science enabled by these data. These and other northern California seismic and geophysical data are available via web services at http://service.ncedc.org

  5. High performance network and channel-based storage

    NASA Technical Reports Server (NTRS)

    Katz, Randy H.

    1991-01-01

    In the traditional mainframe-centered view of a computer system, storage devices are coupled to the system through complex hardware subsystems called input/output (I/O) channels. With the dramatic shift towards workstation-based computing, and its associated client/server model of computation, storage facilities are now found attached to file servers and distributed throughout the network. We discuss the underlying technology trends that are leading to high performance network-based storage, namely advances in networks, storage devices, and I/O controller and server architectures. We review several commercial systems and research prototypes that are leading to a new approach to high performance computing based on network-attached storage.

  6. Lactated Ringer-based storage solutions are equally well suited for the storage of fresh osteochondral allografts as cell culture medium-based storage solutions.

    PubMed

    Harb, Afif; von Horn, Alexander; Gocalek, Kornelia; Schäck, Luisa Marilena; Clausen, Jan; Krettek, Christian; Noack, Sandra; Neunaber, Claudia

    2017-07-01

    Due to the rising interest in Europe to treat large cartilage defects with osteochondrale allografts, research aims to find a suitable solution for long-term storage of osteochondral allografts. This is further encouraged by the fact that legal restrictions currently limit the use of the ingredients from animal or human sources that are being used in other regions of the world (e.g. in the USA). Therefore, the aim of this study was A) to analyze if a Lactated Ringer (LR) based solution is as efficient as a Dulbecco modified Eagle's minimal essential medium (DMEM) in maintaining chondrocyte viability and B) at which storage temperature (4°C vs. 37°C) chondrocyte survival of the osteochondral allograft is optimally sustained. 300 cartilage grafts were collected from knees of ten one year-old Black Head German Sheep. The grafts were stored in four different storage solutions (one of them DMEM-based, the other three based on Lactated Ringer Solution), at two different temperatures (4 and 37°C) for 14 and 56days. At both points in time, chondrocyte survival as well as death rate, Glycosaminoglycan (GAG) content, and Hydroxyproline (HP) concentration were measured and compared between the grafts stored in the different solutions and at the different temperatures. Independent of the storage solutions tested, chondrocyte survival rates were higher when stored at 4°C compared to storage at 37°C both after short-term (14days) and long-term storage (56days). At no point in time did the DMEM-based solution show a superior chondrocyte survival compared to lactated Ringer based solution. GAG and HP content were comparable across all time points, temperatures and solutions. LR based solutions that contain only substances that are approved in Germany may be just as efficient for storing grafts as the USA DMEM-based solution gold standard. Moreover, in the present experiment storage of osteochondral allografts at 4°C was superior to storage at 37°C. Copyright © 2017

  7. Systematic Review of the Effect of Taping Techniques on Patellofemoral Pain Syndrome.

    PubMed

    Logan, Catherine A; Bhashyam, Abhiram R; Tisosky, Ashley J; Haber, Daniel B; Jorgensen, Anna; Roy, Adam; Provencher, Matthew T

    Taping is commonly used in the management of several musculoskeletal conditions, including patellofemoral pain syndrome (PFPS). Specific guidelines for taping are unknown. To investigate the efficacy of knee taping in the management of PFPS. Our hypothesis was that tension taping and exercise would be superior to placebo taping and exercise as well as to exercise or taping alone. The PubMed/MEDLINE, Cochrane, Rehabilitation and Sports Medicine Source, and CINAHL databases were reviewed for English-language randomized controlled trials (RCTs) evaluating the efficacy of various taping techniques that were published between 1995 and April 2015. Keywords utilized included taping, McConnell, kinesio-taping, kinesiotaping, patellofemoral pain, and knee. Studies included consisted of RCTs (level 1 or 2) with participants of all ages who had anterior knee or patellofemoral pain symptoms and had received nonsurgical management using any taping technique. Systematic review. Level 2. A checklist method was used to determine selection, performance, detection, and attrition bias for each article. A quality of evidence grading was then referenced using the validated PEDro database for RCTs. Three difference comparison groups were compared: tension taping and exercise versus placebo taping and exercise (group 1), placebo taping and exercise versus exercise alone (group 2), and tension taping and exercise versus taping alone (group 3). Five RCTs with 235 total patients with multiple intervention arms were included. Taping strategies included McConnell and Kinesiotaping. Visual analog scale (VAS) scores indicated improvement in all 3 comparison groups (group 1: 91 patients, 39% of total, mean VAS improvement 44.9 [tension taping + exercise] vs 66 [placebo taping + exercise]; group 2: 56 patients, 24% of total, mean VAS improvement 66 [placebo taping + exercise] vs 47.6 [exercise alone]; and group 3: 112 patients, 48% of total, mean VAS improvement 44.9 [tension taping + exercise

  8. Aligned Carbon Nanotube Tape for Sensor Applications

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical

  9. TMR tape drive for a 15 TB cartridge

    NASA Astrophysics Data System (ADS)

    Biskeborn, Robert G.; Fontana, Robert E.; Lo, Calvin S.; Czarnecki, W. Stanley; Liang, Jason; Iben, Icko E. T.; Decad, Gary M.; Hipolito, Venus A.

    2018-05-01

    This paper highlights the development of tunnel magnetoresistive (TMR) sensors for magnetic tape recording applications. This has led to the introduction of a tape drives supporting a 15 TB native tape cartridge, currently the highest capacity available. Underscoring this development is the fact that the TMR sensors must run in continual contact with the tape media. This is contrasted with modern hard disk drive (hdd) sensors, which fly above the disk platters. Various challenges encountered in developing and deploying TMR are presented. In addition, advances to the write transducer are also discussed. Lastly, the authors show that future density scaling for tape recording, unlike that for hdd, is not facing limits imposed by photolithography or superparamagnetic physics, suggesting that cartridge capacity improvements of 4 to 6x will be achieved in the next 4 to 8 years.

  10. Multiple Generations on Video Tape Recorders.

    ERIC Educational Resources Information Center

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  11. Editing of EIA coded, numerically controlled, machine tool tapes

    NASA Technical Reports Server (NTRS)

    Weiner, J. M.

    1975-01-01

    Editing of numerically controlled (N/C) machine tool tapes (8-level paper tape) using an interactive graphic display processor is described. A rapid technique required for correcting production errors in N/C tapes was developed using the interactive text editor on the IMLAC PDS-ID graphic display system and two special programs resident on disk. The correction technique and special programs for processing N/C tapes coded to EIA specifications are discussed.

  12. Improving the Spacelab mass memory unit tape layout with a simulation model

    NASA Technical Reports Server (NTRS)

    Noneman, S. R.

    1984-01-01

    A tape drive called the Mass Memory Unit (MMU) stores software used by Spacelab computers. MMU tape motion must be minimized during typical flight operations to avoid a loss of scientific data. A projection of the tape motion is needed for evaluation of candidate tape layouts. A computer simulation of the scheduled and unscheduled MMU tape accesses is developed for this purpose. This simulation permits evaluations of candidate tape layouts by tracking and summarizing tape movements. The factors that affect tape travel are investigated and a heuristic is developed to find a good tape layout. An improved tape layout for Spacelab I is selected after the evaluation of fourteen candidates. The simulation model will provide the ability to determine MMU layouts that substantially decrease the tape travel on future Spacelab flights.

  13. Getting in Taped, Part I and Part II

    ERIC Educational Resources Information Center

    Cundy, H. M.; Higgins, J.

    1971-01-01

    This article is in two parts: discussion of mathematical concepts involved in converting the reading from the tape-recorder counter which counts the turns of the run-off spool to that from the counter which counts turns of the take-up spool; calculating the length of tape run off when given the reading from the tape-recorder counter of the run-off…

  14. Calibration tests on magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.

    1980-01-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  15. An object-based storage model for distributed remote sensing images

    NASA Astrophysics Data System (ADS)

    Yu, Zhanwu; Li, Zhongmin; Zheng, Sheng

    2006-10-01

    It is very difficult to design an integrated storage solution for distributed remote sensing images to offer high performance network storage services and secure data sharing across platforms using current network storage models such as direct attached storage, network attached storage and storage area network. Object-based storage, as new generation network storage technology emerged recently, separates the data path, the control path and the management path, which solves the bottleneck problem of metadata existed in traditional storage models, and has the characteristics of parallel data access, data sharing across platforms, intelligence of storage devices and security of data access. We use the object-based storage in the storage management of remote sensing images to construct an object-based storage model for distributed remote sensing images. In the storage model, remote sensing images are organized as remote sensing objects stored in the object-based storage devices. According to the storage model, we present the architecture of a distributed remote sensing images application system based on object-based storage, and give some test results about the write performance comparison of traditional network storage model and object-based storage model.

  16. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  17. Using S3 cloud storage with ROOT and CvmFS

    NASA Astrophysics Data System (ADS)

    Arsuaga-Ríos, María; Heikkilä, Seppo S.; Duellmann, Dirk; Meusel, René; Blomer, Jakob; Couturier, Ben

    2015-12-01

    Amazon S3 is a widely adopted web API for scalable cloud storage that could also fulfill storage requirements of the high-energy physics community. CERN has been evaluating this option using some key HEP applications such as ROOT and the CernVM filesystem (CvmFS) with S3 back-ends. In this contribution we present an evaluation of two versions of the Huawei UDS storage system stressed with a large number of clients executing HEP software applications. The performance of concurrently storing individual objects is presented alongside with more complex data access patterns as produced by the ROOT data analysis framework. Both Huawei UDS generations show a successful scalability by supporting multiple byte-range requests in contrast with Amazon S3 or Ceph which do not support these commonly used HEP operations. We further report the S3 integration with recent CvmFS versions and summarize the experience with CvmFS/S3 for publishing daily releases of the full LHCb experiment software stack.

  18. Delayed latency of peroneal reflex to sudden inversion with ankle taping or bracing.

    PubMed

    Shima, N; Maeda, A; Hirohashi, K

    2005-01-01

    The purpose of the present study was to examine the effects of ankle taping and bracing based on the peroneal reflex in the hypermobile and normal ankle joints with and without history of ankle injury. Thirty-six ankle joints of 18 collegiate American football athletes with and without previous history of injury were studied. The angle of talar tilt (TT) was measured by stress radiograph for classifying normal (TT5 degrees ) ankles. They were tested with taping, bracing, and without any supports as a control. The latency of peroneus longus muscle was measured by a sudden inversion of 25 degrees using surface EMG signals. The results of the present study show no significant three-way Group (hypermobile or normal ankles) by History (previously injured or uninjured ankles) by Condition (control, taping, or bracing) interaction, while Condition main effect was significant (p<0.05). There were significant differences between control (80.8 ms) and taping (83.8 ms, p<0.01), between control and bracing (83.0 ms, p<0.05), but not between taping and bracing (p>0.05). In conclusion, ankle taping and bracing delayed the peroneal reflex latency not only for hypermobile ankles and/or injured ankle joints but also for intact ankle joints.

  19. Application of infrared spectroscopy and pyrolysis gas chromatography for characterisation of adhesive tapes

    NASA Astrophysics Data System (ADS)

    Zięba-Palus, Janina; Nowińska, Sabina; Kowalski, Rafał

    2016-12-01

    Infrared spectroscopy and pyrolysis GC/MS were applied in the comparative analysis of adhesive tapes. By providing information about the polymer composition, it was possible to classify both backings and adhesives of tapes into defined chemical classes. It was found that samples of the same type (of backings and adhesives) and similar infrared spectra can in most cases be effectively differentiated using Py-GC/MS, sometimes based only on the presence of peaks of very low intensity originating from minor components. The results obtained enabled us to draw the conclusion that Py-GC/MS appears to be a valuable analytical technique for examining tapes, which is complementary to infrared spectroscopy. Identification of pyrolysis products enables discrimination of samples. Both methods also provide crucial information that is useful for identification of adhesive tapes found at the crime scene.

  20. Digital methods of recording color television images on film tape

    NASA Astrophysics Data System (ADS)

    Krivitskaya, R. Y.; Semenov, V. M.

    1985-04-01

    Three methods are now available for recording color television images on film tape, directly or after appropriate finish of signal processing. Conventional recording of images from the screens of three kinescopes with synthetic crystal face plates is still most effective for high fidelity. This method was improved by digital preprocessing of brightness color-difference signal. Frame-by-frame storage of these signals in the memory in digital form is followed by gamma and aperture correction and electronic correction of crossover distortions in the color layers of the film with fixing in accordance with specific emulsion procedures. The newer method of recording color television images with line arrays of light-emitting diodes involves dichromic superposing mirrors and a movable scanning mirror. This method allows the use of standard movie cameras, simplifies interlacing-to-linewise conversion and the mechanical equipment, and lengthens exposure time while it shortens recording time. The latest image transform method requires an audio-video recorder, a memory disk, a digital computer, and a decoder. The 9-step procedure includes preprocessing the total color television signal with reduction of noise level and time errors, followed by frame frequency conversion and setting the number of lines. The total signal is then resolved into its brightness and color-difference components and phase errors and image blurring are also reduced. After extraction of R,G,B signals and colorimetric matching of TV camera and film tape, the simultaneous R,B, B signals are converted from interlacing to sequential triades of color-quotient frames with linewise scanning at triple frequency. Color-quotient signals are recorded with an electron beam on a smoothly moving black-and-white film tape under vacuum. While digital techniques improve the signal quality and simplify the control of processes, not requiring stabilization of circuits, image processing is still analog.

  1. GSFC specification electronic data processing magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.; Perry, J. L.

    1980-01-01

    The design requirements are given for magnetic oxide coated, electronic data processing tape, wound on reels. Magnetic recording tape types covered by this specification are intended for use on digital tape transports using the Non-Return-to-Zero-change-on-ones (NRZI) recording method for recording densities up to and including 800 characters per inch (cpi) and the Phase-Encoding (PE) recording method for a recording density of 1600 cpi.

  2. The Design and Evolution of Jefferson Lab's Jasmine Mass Storage System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryan Hess; M. Andrew Kowalski; Michael Haddox-Schatz

    We describe the Jasmine mass storage system, in operation since 2001. Jasmine has scaled to meet the challenges of grid applications, petabyte class storage, and hundreds of MB/sec throughput using commodity hardware, Java technologies, and a small but focused development team. The evolution of the integrated disk cache system, which provides a managed online subset of the tape contents, is examined in detail. We describe how the storage system has grown to meet the special needs of the batch farm, grid clients, and new performance demands.

  3. Portable digital pressure indicator for calibrating magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Mccormick, Royce F.; Leighty, Bradley D.

    1989-01-01

    The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

  4. OCLC-MARC Tape Processing: A Functional Analysis.

    ERIC Educational Resources Information Center

    Miller, Bruce Cummings

    1984-01-01

    Analyzes structure of, and data in, the OCLC-MARC record in the form delivered via OCLC's Tape Subscription Service, and outlines important processing functions involved: "unreadable tapes," duplicate records and deduping, match processing, choice processing, locations processing, "automatic" and "input" stamps,…

  5. Superconducting magnetic energy storage and superconducting self-supplied electromagnetic launcher

    NASA Astrophysics Data System (ADS)

    Ciceron, Jérémie; Badel, Arnaud; Tixador, Pascal

    2017-10-01

    Superconductors can be used to build energy storage systems called Superconducting Magnetic Energy Storage (SMES), which are promising as inductive pulse power source and suitable for powering electromagnetic launchers. The second generation of high critical temperature superconductors is called coated conductors or REBCO (Rare Earth Barium Copper Oxide) tapes. Their current carrying capability in high magnetic field and their thermal stability are expanding the SMES application field. The BOSSE (Bobine Supraconductrice pour le Stockage d'Energie) project aims to develop and to master the use of these superconducting tapes through two prototypes. The first one is a SMES with high energy density. Thanks to the performances of REBCO tapes, the volume energy and specific energy of existing SMES systems can be surpassed. A study has been undertaken to make the best use of the REBCO tapes and to determine the most adapted topology in order to reach our objective, which is to beat the world record of mass energy density for a superconducting coil. This objective is conflicting with the classical strategies of superconducting coil protection. A different protection approach is proposed. The second prototype of the BOSSE project is a small-scale demonstrator of a Superconducting Self-Supplied Electromagnetic Launcher (S3EL), in which a SMES is integrated around the launcher which benefits from the generated magnetic field to increase the thrust applied to the projectile. The S3EL principle and its design are presented. Contribution to the topical issue "Electrical Engineering Symposium (SGE 2016)", edited by Adel Razek

  6. The anomaly data base of screwworm information

    NASA Technical Reports Server (NTRS)

    Giddings, L. E.

    1976-01-01

    Standard statistical processing of anomaly data in the screwworm eradication data system is possible from data compiled on magnetic tapes with the Univac 1108 computer. The format and organization of the data in the data base, which is also available on dedicated disc storage, are described.

  7. Gas storage using fullerene based adsorbents

    NASA Technical Reports Server (NTRS)

    Mikhael, Michael G. (Inventor); Loutfy, Raouf O. (Inventor); Lu, Xiao-Chun (Inventor); Li, Weijiong (Inventor)

    2000-01-01

    This invention is directed to the synthesis of high bulk density high gas absorption capacity adsorbents for gas storage applications. Specifically, this invention is concerned with novel gas absorbents with high gravimetric and volumetric gas adsorption capacities which are made from fullerene-based materials. By pressing fullerene powder into pellet form using a conventional press, then polymerizing it by subjecting the fullerene to high temperature and high inert gas pressure, the resulting fullerene-based materials have high bulk densities and high gas adsorption capacities. By pre-chemical modification or post-polymerization activation processes, the gas adsorption capacities of the fullerene-based adsorbents can be further enhanced. These materials are suitable for low pressure gas storage applications, such as oxygen storage for home oxygen therapy uses or on-board vehicle natural gas storage. They are also suitable for storing gases and vapors such as hydrogen, nitrogen, carbon dioxide, and water vapor.

  8. Method and apparatus for depositing a coating on a tape carrier

    DOEpatents

    Storer, Jonathan; Matias, Vladimir

    2010-06-15

    A system and method for depositing ceramic materials, such as nitrides and oxides, including high temperature superconducting oxides on a tape substrate. The system includes a tape support assembly that comprises a rotatable drum. The rotatable drum supports at least one tape substrate axially disposed on the surface of the drum during the deposition of metals on the tape and subsequent oxidation to form the ceramic materials. The drum is located within a stator having a slot that is axially aligned with the drum. A space exists between the drum and stator. The space is filled with a predetermined partial pressure of a reactive gas. The drum, stator, and space are heated to a predetermined temperature. To form the ceramic material on the tape substrate, the drum is first rotated to align the tape substrate with the slot, and at least one metal is deposited on the substrate. The drum then continues to rotate, bringing the tape substrate into the space, where the metal deposited on the tape substrate reacts with the reactive gas to form the ceramic material. In one embodiment, the tape support system also includes a pay-out/take-up system that co-rotates with the drum and provides a continuous length of tape substrate.

  9. Numerical and Experimental Investigation of the Electromechanical Behavior of REBCO Tapes

    NASA Astrophysics Data System (ADS)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2015-12-01

    To fully characterize the electromechanical behavior of a Twisted Stacked-Tape Cable (TSTC) it is important to understand the performance of the individual REBCO tapes under various loading conditions. Numerical modeling and experimentation have been used to investigate the electromechanical characteristics of two commercially available REBCO tapes (SuperPower and SuNAM). Tension and combined tension-torsion experiments on single tapes have been continued, from prior preliminary studies, to characterize their critical current behavior and mechanical strength. Additionally, structural finite element analysis was performed on single tapes under tension and combined tension-torsion to investigate the strain dependence of the critical current. The numerical results were compared to the experimental findings for validation. The SuNAM experimental data matched the numerical model very well while the SuperPower tape experienced degradation at lower stress and strain than predicted in the model. The Superpower tape also displayed greater variability in critical current between different samples as compared with the SuNAM tape.

  10. Star Catalogs on Punched Cards and Magnetic Tape

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1961-01-01

    In connection with the calibration of the Minitrack satellite tracking stations, the Goddard Space Flight Center has had the contents of a number of star catalogs put on punched cards and magnetic tape. This report discusses the plate data reduction procedures, briefly describes the information on the punched cards and magnetic tape, and calls attention to other applications of the card and tape star catalogs. The Goddard Space Flight Center has offered to prepare duplicate catalogs for qualified organizations.

  11. Ceramic-metal composites prepared via tape casting and melt infiltration methods

    NASA Astrophysics Data System (ADS)

    Kim, Hyun Jun

    Melt infiltration of preforms prepared by tape casting and lamination has been accomplished using a short-time infiltration process that significantly suppresses reaction product formation. For layered materials produced via infiltration of laminated ceramic tapes, of particular interest is the effect that a large change in microstructure has on infiltration, phase formation, and mechanical properties. Hardness of the fine scale composite layers is approximately three times higher than coarse scale layers, due to greater strength of the fine B4C network. Fractography showed that crack propagation occurred by brittle fracture of the carbide and ductile extension of the metal. Despite large differences in hardness, the fracture mode of the fine and coarse scale microstructures appears identical. Fluid flow modeling for tape casting was conducted with a Newtonian slurry under a parallel blade, and the effect of beveling the blade based on a one dimensional flow model is shown. The discussion on slurry deformation after the blade exit suggests that the mode of slurry deformation depends on the relative importance of the pressure gradient and wall shear and that the existence of zero shear plane might have a negative effect on particle alignment in the tape. The analysis of the flow under a beveled blade predicts that this configuration is more advantageous than the parallel blade for productivity and parallel blade is better for producing uniform particle alignment and thinner tape. Also, the one dimensional flow model for the beveled blade is shown to be a valid approximation of the fluid behavior below a blade angle of 45 degrees. The flow visualization study on tape casting was conducted with a transparent apparatus and model slurry. Most investigators have concluded that the shear stress between the doctor blade and moving carrier causes the particle alignment, but, according to the result of visualization experiment, some degree of particle alignment is already

  12. Effect of tape stripping and adjuvants on immune response after intradermal DNA electroporation.

    PubMed

    Vandermeulen, Gaëlle; Daugimont, Liévin; Richiardi, Hervé; Vanderhaeghen, Marie-Lise; Lecouturier, Nathalie; Ucakar, Bernard; Préat, Véronique

    2009-07-01

    DNA vaccines require both efficient delivery methods and appropriate adjuvants. Based on their mechanisms of action, we hypothesised that some adjuvants could enhance vaccine immunogenicity or direct the response towards Th1 profile after intradermal DNA electroporation. After intradermal electroporation of plasmid DNA encoding luciferase, mice received hyaluronidase, imiquimod, monophosphoryl lipid A or were tape stripped in order to modulate the immune response against the encoded protein. We measured total immunoglobulin G, IgG1, IgG2a titres and the cytokines produced by splenocyte cultures to assess both humoral and cellular response. The effect of tape stripping on the response against intradermally delivered ovalbumin protein was also assessed. Neither hyaluronidase nor imiquimod improved the immune response against the encoded luciferase. Monophosphoryl lipid A did not modify the cytokines production but increased the anti-luciferase IgG2a titres. Tape stripping significantly increased anti-luciferase IgG2a and IFN-gamma responses. It also enhanced the humoral response after intradermal injection of the ovalbumin protein. Tape stripping is able to increase the Th1 immune response against both DNA and protein vaccines. Therefore, tape stripping appears to have interesting adjuvant effect on intradermal vaccination.

  13. Comparison study of cable geometries and superconducting tape layouts for high-temperature superconductor cables

    NASA Astrophysics Data System (ADS)

    Ta, Wurui; Shao, Tianchong; Gao, Yuanwen

    2018-04-01

    High-temperature superconductor (HTS) rare-earth-barium-copper-oxide (REBCO) tapes are very promising for use in high-current cables. The cable geometry and the layout of the superconducting tapes are directly related to the performance of the HTS cable. In this paper, we use numerical methods to perform a comparison study of multiple-stage twisted stacked-tape cable (TSTC) conductors to find better cable structures that can both improve the critical current and minimize the alternating current (AC) losses of the cable. The sub-cable geometry is designed to have a stair-step shape. Three superconducting tape layouts are chosen and their transport performance and AC losses are evaluated. The magnetic field and current density profiles of the cables are obtained. The results show that arrangement of the superconducting tapes from the interior towards the exterior of the cable based on their critical current values in descending order can enhance the cable's transport capacity while significantly reducing the AC losses. These results imply that cable transport capacity improvements can be achieved by arranging the superconducting tapes in a manner consistent with the electromagnetic field distribution. Through comparison of the critical currents and AC losses of four types of HTS cables, we determine the best structural choice among these cables.

  14. NIMBUS 7 Earth Radiation Budget (ERB) Matrix User's Guide. Volume 2: Tape Specifications

    NASA Technical Reports Server (NTRS)

    Ray, S. N.; Vasanth, K. L.

    1984-01-01

    The ERB MATRIX tape is generated by an IBM 3081 computer program and is a 9 track, 1600 BPI tape. The gross format of the tape given on Page 1, shows an initial standard header file followed by data files. The standard header file contains two standard header records. A trailing documentation file (TDF) is the last file on the tape. Pages 9 through 17 describe, in detail, the standard header file and the TDF. The data files contain data for 37 different ERB parameters. Each file has data based on either a daily, 6 day cyclic, or monthly time interval. There are three types of physical records in the data files; namely, the world grid physical record, the documentation mercator/polar map projection physical record, and the monthly calibration physical record. The manner in which the data for the 37 ERB parameters are stored in the physical records comprising the data files, is given in the gross format section.

  15. Laser-assisted patterning of double-sided adhesive tapes for optofluidic chip integration

    NASA Astrophysics Data System (ADS)

    Zamora, Vanessa; Janeczka, Christian; Arndt-Staufenbiel, Norbert; Havlik, George; Queisser, Marco; Schröder, Henning

    2018-02-01

    Portable high-sensitivity biosensors exhibit a growing demand in healthcare, food industry and environmental monitoring sectors. Optical biosensors based on photonic integration platforms are attractive candidates due to their high sensitivity, compactness and multiplexing capabilities. However, they need a low-cost and reliable integration with the microfluidic system. Laser-micropatterned double-sided biocompatible adhesive tapes are promising bonding layers for hybrid integration of an optofluidic biochip. As a part of the EU-PHOCNOSIS project, double-sided adhesive tapes have been proposed to integrate the polymer microfluidic system with the optical integrated waveguide sensor chip. Here the adhesive tape should be patterned in a micrometer scale in order to create an interaction between the sample that flows through the polymer microchannel and the photonic sensing microstructure. Three laser-assisted structuring methods are investigated to transfer microchannel patterns to the adhesive tape. The test structure design consists of a single channel with 400 μm wide, 30 mm length and two circular receivers with 3 mm radius. The best structuring results are found by using the picosecond UV laser where smooth and straight channel cross-sections are obtained. Such patterned tapes are used to bond blank polymer substrates to blank silicon substrates. As a proof of concept, the hybrid integration is tested using colored DI-water. Structuring tests related to the reduction of channel widths are also considered in this work. The use of this technique enables a simple and rapid manufacturing of narrow channels (50-60 μm in width) in adhesive tapes, achieving a cheap and stable integration of the optofluidic biochip.

  16. The NT digital micro tape recorder

    NASA Technical Reports Server (NTRS)

    Sasaki, Toshikazu; Alstad, John; Younker, Mike

    1993-01-01

    The description of an audio recorder may at first glance seem out of place in a conference which has been dedicated to the discussion of the technology and requirements of mass data storage. However, there are several advanced features of the NT system which will be of interest to the mass storage technologist. Moreover, there are a sufficient number of data storage formats in current use which have evolved from their audio counterparts to recommend a close attention to major innovative introductions of audio storage formats. While the existing analog micro-cassette recorder has been (and will continue to be) adequate for various uses, there are significant benefits to be gained through the application of digital technology. The elimination of background tape hiss and the availability of two relatively wide band channels (for stereo recording), for example, would greatly enhance listenability and speech intelligibility. And with the use of advanced high-density recording and LSI circuit technologies, a digital micro recorder can realize unprecedented compactness with excellent energy efficiency. This is what was accomplished with the NT-1 Digital Micro Recorder. Its remarkably compact size contributes to its portability. The high-density NT format enables up to two hours of low-noise digital stereo recording on a cassette the size of a postage stamp. Its highly energy-efficient mechanical and electrical design results in low power consumption; the unit can be operated up to 7 hours (for continuous recording) on a single AA alkaline battery. Advanced user conveniences include a multifunction LCD readout. The unit's compactness and energy-efficiency, in particular, are attributes that cannot be matched by existing analog and digital audio formats. The size, performance, and features of the NT format are of benefit primarily to those who desire improved portability and audio quality in a personal memo product. The NT Recorder is the result of over ten years of

  17. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    NASA Astrophysics Data System (ADS)

    Takayasu, Makoto; Chiesa, Luisa

    2015-12-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour.

  18. Cassette Tape Catalog: 1980/1981 Unabridged Supplement.

    ERIC Educational Resources Information Center

    American Child Care Services, Hampton, VA.

    This unabridged supplement to the Child Care Information Center's tape cassette catalog contains a listing of all recordings made in calendar years 1980 and 1981. This document plus "The Revised 1976 Cassette Tape Catalog,""The 1977 Addendum," and "The 1978/1979 Unabridged Supplement" together provide a complete listing of the 1,776 tape…

  19. 12. "TAPE ROOM" LOCATED AT SOUTHEAST CORNER OF MAIN ROOM. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. "TAPE ROOM" LOCATED AT SOUTHEAST CORNER OF MAIN ROOM. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Instrumentation & Control Building, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  20. Online data handling and storage at the CMS experiment

    NASA Astrophysics Data System (ADS)

    Andre, J.-M.; Andronidis, A.; Behrens, U.; Branson, J.; Chaze, O.; Cittolin, S.; Darlea, G.-L.; Deldicque, C.; Demiragli, Z.; Dobson, M.; Dupont, A.; Erhan, S.; Gigi, D.; Glege, F.; Gómez-Ceballos, G.; Hegeman, J.; Holzner, A.; Jimenez-Estupiñán, R.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, RK; Morovic, S.; Nuñez-Barranco-Fernández, C.; O'Dell, V.; Orsini, L.; Paus, C.; Petrucci, A.; Pieri, M.; Racz, A.; Roberts, P.; Sakulin, H.; Schwick, C.; Stieger, B.; Sumorok, K.; Veverka, J.; Zaza, S.; Zejdl, P.

    2015-12-01

    During the LHC Long Shutdown 1, the CMS Data Acquisition (DAQ) system underwent a partial redesign to replace obsolete network equipment, use more homogeneous switching technologies, and support new detector back-end electronics. The software and hardware infrastructure to provide input, execute the High Level Trigger (HLT) algorithms and deal with output data transport and storage has also been redesigned to be completely file- based. All the metadata needed for bookkeeping are stored in files as well, in the form of small documents using the JSON encoding. The Storage and Transfer System (STS) is responsible for aggregating these files produced by the HLT, storing them temporarily and transferring them to the T0 facility at CERN for subsequent offline processing. The STS merger service aggregates the output files from the HLT from ∼62 sources produced with an aggregate rate of ∼2GB/s. An estimated bandwidth of 7GB/s in concurrent read/write mode is needed. Furthermore, the STS has to be able to store several days of continuous running, so an estimated of 250TB of total usable disk space is required. In this article we present the various technological and implementation choices of the three components of the STS: the distributed file system, the merger service and the transfer system.

  1. Medical image digital archive: a comparison of storage technologies

    NASA Astrophysics Data System (ADS)

    Chunn, Timothy; Hutchings, Matt

    1998-07-01

    A cost effective, high capacity digital archive system is one of the remaining key factors that will enable a radiology department to eliminate film as an archive medium. The ever increasing amount of digital image data is creating the need for huge archive systems that can reliably store and retrieve millions of images and hold from a few terabytes of data to possibly hundreds of terabytes. Selecting the right archive solution depends on a number of factors: capacity requirements, write and retrieval performance requirements, scaleability in capacity and performance, conformance to open standards, archive availability and reliability, security, cost, achievable benefits and cost savings, investment protection, and more. This paper addresses many of these issues. It compares and positions optical disk and magnetic tape technologies, which are the predominant archive mediums today. New technologies will be discussed, such as DVD and high performance tape. Price and performance comparisons will be made at different archive capacities, plus the effect of file size on random and pre-fetch retrieval time will be analyzed. The concept of automated migration of images from high performance, RAID disk storage devices to high capacity, NearlineR storage devices will be introduced as a viable way to minimize overall storage costs for an archive.

  2. Patellar taping, patellofemoral pain syndrome, lower extremity kinematics, and dynamic postural control.

    PubMed

    Aminaka, Naoko; Gribble, Phillip A

    2008-01-01

    Patellar taping has been a part of intervention for treatment of patellofemoral pain syndrome (PFPS). However, research on the efficacy of patellar taping on lower extremity kinematics and dynamic postural control is limited. To evaluate the effects of patellar taping on sagittal-plane hip and knee kinematics, reach distance, and perceived pain level during the Star Excursion Balance Test (SEBT) in individuals with and without PFPS. Repeated-measures design with 2 within-subjects factors and 1 between-subjects factor. The University of Toledo Athletic Training Research Laboratory. Twenty participants with PFPS and 20 healthy participants between the ages of 18 and 29 years. The participants performed 3 reaches of the SEBT in the anterior direction under tape and no-tape conditions on both legs. The participants' hip and knee sagittal-plane kinematics were measured using the electromagnetic tracking system. Reach distance was recorded by hand and was normalized by dividing the distance by the participants' leg length (%MAXD). After each taping condition on each leg, the participants rated the perceived pain level using the 10-cm visual analog scale. The participants with PFPS had a reduction in pain level with patellar tape application compared with the no-tape condition (P = .005). Additionally, participants with PFPS demonstrated increased %MAXD under the tape condition compared with the no-tape condition, whereas the healthy participants demonstrated decreased %MAXD with tape versus no tape (P = .028). No statistically significant differences were noted in hip flexion and knee flexion angles. Although patellar taping seemed to reduce pain and improve SEBT performance of participants with PFPS, the exact mechanisms of these phenomena cannot be explained in this study. Further research is warranted to investigate the effect of patellar taping on neuromuscular control during dynamic postural control.

  3. Dry Process for Making Polyimide/ Carbon-and-Boron-Fiber Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Johnston, Norman J.; Marchello, Joseph M.

    2003-01-01

    A dry process has been invented as an improved means of manufacturing composite prepreg tapes that consist of high-temperature thermoplastic polyimide resin matrices reinforced with carbon and boron fibers. Such tapes are used (especially in the aircraft industry) to fabricate strong, lightweight composite-material structural components. The inclusion of boron fibers results in compression strengths greater than can be achieved by use of carbon fibers alone. The present dry process is intended to enable the manufacture of prepreg tapes (1) that contain little or no solvent; (2) that have the desired dimensions, fiber areal weight, and resin content; and (3) in which all of the fibers are adequately wetted by resin and the boron fibers are fully encapsulated and evenly dispersed. Prepreg tapes must have these properties to be useable in the manufacture of high-quality composites by automated tape placement. The elimination of solvent and the use of automated tape placement would reduce the overall costs of manufacturing.

  4. LGSOWG CCT format CCB document: The standard CCT family of tape formats

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The tape format standardization approach recommended by the committee on CCT standardization is described and defined. All rules and conventions required to employ the superstructure approach to the CCT family of tape formats are presented for users of remote sensing data and producer of user tapes and the superstructure records are specified. The standard for future tape format design is presented as a guide to designing data records of a particular tape format. An example is provided showing how to incorporate the superstructure into an already established tape format.

  5. Personal miniature electrophysiological tape recorder

    NASA Astrophysics Data System (ADS)

    Green, H.

    1981-11-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  6. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, E.B.; Muller, A.C.

    1983-07-15

    The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

  7. Superconducting flat tape cable magnet

    DOEpatents

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  8. 75 FR 14628 - Pressure Sensitive Plastic Tape From Italy; Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... Plastic Tape From Italy; Determination On the basis of the record \\1\\ developed in the subject five-year... pressure sensitive plastic tape from Italy would be likely to lead to continuation or recurrence of... Publication 4128 (March 2010), entitled Pressure Sensitive Plastic Tape from Italy: Investigation No. AA1921...

  9. STS-88 Mission Highlights Resources Tape. Tape B

    NASA Technical Reports Server (NTRS)

    1999-01-01

    The STS-88 flight crew, Commander Robert D. Cabana, Pilot Frederick W. Sturckow, and Mission Specialists Nancy J. Currie, James H. Newman, Jerry L. Ross, and Sergei Krikalev present a video overview of their space flight. Tape two of three includes the installation of an S-Band to help monitor the UNITY Connecting Module, the opening of UNITY's hatch, the opening of the main compartment hatch to ZARYA Control Module, and the repair of the inflight maintenance system.

  10. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    PubMed

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-07

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  11. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  12. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  13. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  14. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  15. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that consists...

  16. Ankle taping does not impair performance in jump or balance tests.

    PubMed

    Abián-Vicén, Javier; Alegre, Luis M; Fernández-Rodríguez, J Manuel; Lara, Amador J; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces.

  17. Ankle Taping Does Not Impair Performance in Jump or Balance Tests

    PubMed Central

    Abián-Vicén, Javier; Alegre, Luis M.; Fernández-Rodríguez, J. Manuel; Lara, Amador J.; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces. PMID:24149902

  18. A self-configuring control system for storage and computing departments at INFN-CNAF Tierl

    NASA Astrophysics Data System (ADS)

    Gregori, Daniele; Dal Pra, Stefano; Ricci, Pier Paolo; Pezzi, Michele; Prosperini, Andrea; Sapunenko, Vladimir

    2015-05-01

    The storage and farming departments at the INFN-CNAF Tier1[1] manage approximately thousands of computing nodes and several hundreds of servers that provides access to the disk and tape storage. In particular, the storage server machines should provide the following services: an efficient access to about 15 petabytes of disk space with different cluster of GPFS file system, the data transfers between LHC Tiers sites (Tier0, Tier1 and Tier2) via GridFTP cluster and Xrootd protocol and finally the writing and reading data operations on magnetic tape backend. One of the most important and essential point in order to get a reliable service is a control system that can warn if problems arise and which is able to perform automatic recovery operations in case of service interruptions or major failures. Moreover, during daily operations the configurations can change, i.e. if the GPFS cluster nodes roles can be modified and therefore the obsolete nodes must be removed from the control system production, and the new servers should be added to the ones that are already present. The manual management of all these changes is an operation that can be somewhat difficult in case of several changes, it can also take a long time and is easily subject to human error or misconfiguration. For these reasons we have developed a control system with the feature of self-configure itself if any change occurs. Currently, this system has been in production for about a year at the INFN-CNAF Tier1 with good results and hardly any major drawback. There are three major key points in this system. The first is a software configurator service (e.g. Quattor or Puppet) for the servers machines that we want to monitor with the control system; this service must ensure the presence of appropriate sensors and custom scripts on the nodes to check and should be able to install and update software packages on them. The second key element is a database containing information, according to a suitable format, on

  19. Gait Kinematics After Taping in Participants With Chronic Ankle Instability

    PubMed Central

    Chinn, Lisa; Dicharry, Jay; Hart, Joseph M.; Saliba, Susan; Wilder, Robert; Hertel, Jay

    2014-01-01

    Context: Chronic ankle instability is characterized by repetitive lateral ankle sprains. Prophylactic ankle taping is a common intervention used to reduce the risk of ankle sprains. However, little research has been conducted to evaluate the effect ankle taping has on gait kinematics. Objective: To investigate the effect of taping on ankle and knee kinematics during walking and jogging in participants with chronic ankle instability. Design: Controlled laboratory study. Setting: Motion analysis laboratory. Patients or Participants: A total of 15 individuals (8 men, 7 women; age = 26.9 ± 6.8 years, height = 171.7 ± 6.3 cm, mass = 73.5 ± 10.7 kg) with self-reported chronic ankle instability volunteered. They had an average of 5.3 ± 3.1 incidences of ankle sprain. Intervention(s): Participants walked and jogged in shoes on a treadmill while untaped and taped. The tape technique was a traditional preventive taping procedure. Conditions were randomized. Main Outcome Measure(s): Frontal-plane and sagittal-plane ankle and sagittal-plane knee kinematics were recorded throughout the entire gait cycle. Group means and 90% confidence intervals were calculated, plotted, and inspected for percentages of the gait cycle in which the confidence intervals did not overlap. Results: During walking, participants were less plantar flexed from 64% to 69% of the gait cycle (mean difference = 5.73° ± 0.54°) and less inverted from 51% to 61% (mean difference = 4.34° ± 0.65°) and 76% to 81% (mean difference = 5.55° ± 0.54°) of the gait cycle when taped. During jogging, participants were less dorsiflexed from 12% to 21% (mean difference = 4.91° ± 0.18°) and less inverted from 47% to 58% (mean difference = 6.52° ± 0.12°) of the gait cycle when taped. No sagittal-plane knee kinematic differences were found. Conclusions: In those with chronic ankle instability, taping resulted in a more neutral ankle position during walking and jogging in shoes on a treadmill. This change in

  20. Experiments and FE modeling of stress-strain state in ReBCO tape under tensile, torsional and transverse load

    NASA Astrophysics Data System (ADS)

    Ilin, K.; Yagotintsev, K. A.; Zhou, C.; Gao, P.; Kosse, J.; Otten, S. J.; Wessel, W. A. J.; Haugan, T. J.; van der Laan, D. C.; Nijhuis, A.

    2015-05-01

    For high current superconductors in high magnet fields with currents in the order of 50 kA, single ReBCO coated conductors must be assembled in a cable. The geometry of such a cable is mostly such that combined torsion, axial and transverse loading states are anticipated in the tapes and tape joints. The resulting strain distribution, caused by different thermal contraction and electromagnetic forces, will affect the critical current of the tapes. Tape performance when subjected to torsion, tensile and transverse loading is the key to understanding limitations for the composite cable performance. The individual tape material components can be deformed, not only elastically but also plastically under these loads. A set of experimental setups, as well as a convenient and accurate method of stress-strain state modeling based on the finite element method have been developed. Systematic measurements on single ReBCO tapes are carried out combining axial tension and torsion as well as transverse loading. Then the behavior of a single tape subjected to the various applied loads is simulated in the model. This paper presents the results of experimental tests and detailed FE modeling of the 3D stress-strain state in a single ReBCO tape under different loads, taking into account the temperature dependence and the elastic-plastic properties of the tape materials, starting from the initial tape processing conditions during its manufacture up to magnet operating conditions. Furthermore a comparison of the simulations with experiments is presented with special attention for the critical force, the threshold where the tape performance becomes irreversibly degraded. We verified the influence of tape surface profile non-uniformity and copper stabilizer thickness on the critical force. The FE models appear to describe the tape experiments adequately and can thus be used as a solid basis for optimization of various cabling concepts.

  1. Analysis of transient state in HTS tapes under ripple DC load current

    NASA Astrophysics Data System (ADS)

    Stepien, M.; Grzesik, B.

    2014-05-01

    The paper concerns the analysis of transient state (quench transition) in HTS tapes loaded with the current having DC component together with a ripple component. Two shapes of the ripple were taken into account: sinusoidal and triangular. Very often HTS tape connected to a power electronic current supply (i.e. superconducting coil for SMES) that delivers DC current with ripples and it needs to be examined under such conditions. Additionally, measurements of electrical (and thermal) parameters under such ripple excitation is useful to tape characterization in broad range of load currents. The results presented in the paper were obtained using test bench which contains programmable DC supply and National Instruments data acquisition system. Voltage drops and load currents were measured vs. time. Analysis of measured parameters as a function of the current was used to tape description with quench dynamics taken into account. Results of measurements were also used to comparison with the results of numerical modelling based on FEM. Presented provisional results show possibility to use results of measurements in transient state to prepare inverse models of superconductors and their detailed numerical modelling.

  2. Errata, nursing homes. Budget percentiles for baseline and redesigned commercial type buildings: cities with try weather tapes; based on resource utilization factors (RUF); based on price weighting factors (PWF)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Corrected data are presented for the P50 Redesign figure for nursing homes in the following documents in the series entitled Budget Percentiles for Baseline and Redesigned Commercial Type Buildings: For Cities with TRY Weather Tapes, Based on Price Weighing Factors (PWF), and Based on Resource Utilization Factors (RUF). (MCW)

  3. Goddard Conference on Mass Storage Systems and Technologies, Volume 1

    NASA Technical Reports Server (NTRS)

    Kobler, Ben (Editor); Hariharan, P. C. (Editor)

    1993-01-01

    Copies of nearly all of the technical papers and viewgraphs presented at the Goddard Conference on Mass Storage Systems and Technologies held in Sep. 1992 are included. The conference served as an informational exchange forum for topics primarily relating to the ingestion and management of massive amounts of data and the attendant problems (data ingestion rates now approach the order of terabytes per day). Discussion topics include the IEEE Mass Storage System Reference Model, data archiving standards, high-performance storage devices, magnetic and magneto-optic storage systems, magnetic and optical recording technologies, high-performance helical scan recording systems, and low end helical scan tape drives. Additional topics addressed the evolution of the identifiable unit for processing purposes as data ingestion rates increase dramatically, and the present state of the art in mass storage technology.

  4. The statistical evaluation of duct tape end match as physical evidence

    NASA Astrophysics Data System (ADS)

    Chan, Ka Lok

    Duct tapes are often submitted to crime laboratories as evidence associated with abductions, homicides, or construction of explosive devices. As a result, trace evidence examiners are often asked to analyze and compare commercial duct tapes so that they can establish possible evidentiary links. Duct tape end matches are believed to be the strongest association between exemplar and question samples because they are considered as evidence with unique individual characteristics. While end match analysis and comparison have long been undertaken by trace evidence examiners, there is a significant lack of scientific research for associating two or more segments of duct tapes. This study is designed to obtain statistical inferences on the uniqueness of duct tape tears. Three experiments were devised to compile the basis for a statistical assessment of the probability of duct tape end matches along with a proposed error rate. In one experiment, we conducted the equivalent of 10,000 end match examinations with an error rate of 0%. In the second experiment, we performed 2,704 end match examinations having 0% error rate. In the third experiment, using duct tape by an Elmendorf Tear tester, we conducted 576 end match examinations with an error rate of 0% and having all samples correctly associated. The results of this study indicate that end matches are distinguishable among a single roll of duct tape and between two different rolls of duct tape having very similar surface features and weave pattern.

  5. Kinesio® Tape Barrier Does Not Inhibit Intramuscular Cooling During Cryotherapy.

    PubMed

    Lyman, Katie J; McCrone, Michael; Hanson, Thomas A; Mellinger, Christopher D; Gange, Kara

    2018-05-29

    Allied health care professionals commonly apply cryotherapy as treatment for acute musculoskeletal trauma and the associated symptoms. Understanding the impact of a tape barrier on intramuscular temperature can assist in determining treatment duration for effective cryotherapy. To determine whether Kinesio® Tape acts as a barrier that affects intramuscular temperature during cryotherapy application. A repeated-measures, counterbalanced design in which the independent variable was tape application and the dependent variable was muscle temperature as measured by thermocouples placed 1 cm beneath the adipose layer. Additional covariates for robustness were BMI and adipose thickness. University research laboratory. 19 male college students with no contraindications to cryotherapy, no known sensitivity to Kinesio® Tape, and no reported quadriceps injury within the past six months. Topical cryotherapy: crushed-ice bags of 1 kg and 0.5 kg. Intramuscular temperature. The tape barrier had no statistically significant effect on muscle temperature. The pattern of temperature change was indistinguishable between participants with and without tape application. Findings suggest health care professionals can combine cryotherapy with a Kinesio® Tape application without any need for adjustments to cryotherapy duration.

  6. Friction and morphology of magnetic tapes in sliding contact with nickel-zinc ferrite

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.; Bhushan, B.

    1984-01-01

    Friction and morphological studies were conducted with magnetic tapes containing a Ni-Zn ferrite hemispherical pin in laboratory air at a relative humidity of 40 percent and at 23 C. The results indicate that the binder plays a significant role in the friction properties, morphology, and microstructure of the tape. Comparisons were made with four binders: nitrocellulose; poly (vinyledene) chloride; cellulose acetate; and hydroxyl-terminated, low molecular weight polyester added to the base polymer, polyester-polyurethane. The coefficient of friction was lowest for the tape with the nitrocellulose binder and increased in the order hydroxylterminated, low molecular weight polyester resin; poly (vinyledene) chloride; and cellulose acetate. The degree of enclosure of the oxide particles by the binder was highest for hydroxyl-terminated, low molecular weight polyester and decreased in the order cellulose acetate, poly (vinyledene) chloride, and nitrocellulose. The nature of deformation of the tape was a factor in controlling friction. The coefficient of friction under elastic contact conditions was considerably lower than under conditions that produced plastic contacts.

  7. Analysis of particulates on tape lift samples

    NASA Astrophysics Data System (ADS)

    Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling

    2014-09-01

    Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.

  8. GAMBIT: the global and modular beyond-the-standard-model inference tool. Addendum for GAMBIT 1.1: Mathematica backends, SUSYHD interface and updated likelihoods

    NASA Astrophysics Data System (ADS)

    Athron, Peter; Balazs, Csaba; Bringmann, Torsten; Buckley, Andy; Chrząszcz, Marcin; Conrad, Jan; Cornell, Jonathan M.; Dal, Lars A.; Dickinson, Hugh; Edsjö, Joakim; Farmer, Ben; Gonzalo, Tomás E.; Jackson, Paul; Krislock, Abram; Kvellestad, Anders; Lundberg, Johan; McKay, James; Mahmoudi, Farvah; Martinez, Gregory D.; Putze, Antje; Raklev, Are; Ripken, Joachim; Rogan, Christopher; Saavedra, Aldo; Savage, Christopher; Scott, Pat; Seo, Seon-Hee; Serra, Nicola; Weniger, Christoph; White, Martin; Wild, Sebastian

    2018-02-01

    In Ref. (GAMBIT Collaboration: Athron et. al., Eur. Phys. J. C. arXiv:1705.07908, 2017) we introduced the global-fitting framework GAMBIT. In this addendum, we describe a new minor version increment of this package. GAMBIT 1.1 includes full support for Mathematica backends, which we describe in some detail here. As an example, we backend SUSYHD (Vega and Villadoro, JHEP 07:159, 2015), which calculates the mass of the Higgs boson in the MSSM from effective field theory. We also describe updated likelihoods in PrecisionBit and DarkBit, and updated decay data included in DecayBit.

  9. Effects of kinesio taping and hot packs on premenstrual syndrome in females.

    PubMed

    Choi, Jung-Hyun

    2017-09-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome.

  10. Effects of kinesio taping and hot packs on premenstrual syndrome in females

    PubMed Central

    Choi, Jung-Hyun

    2017-01-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome. PMID:28931978

  11. Accuracy of the Broselow Tape in South Sudan, "The Hungriest Place on Earth".

    PubMed

    Clark, Melissa C; Lewis, Roger J; Fleischman, Ross J; Ogunniyi, Adedamola A; Patel, Dipesh S; Donaldson, Ross I

    2016-01-01

    The Broselow tape is a length-based tool used for the rapid estimation of pediatric weight and was developed to reduce dosage-related errors during emergencies. This study seeks to assess the accuracy of the Broselow tape and age-based formulas in predicting weights of South Sudanese children of varying nutritional status. This was a retrospective, cross-sectional study using data from existing acute malnutrition screening programs for children less than 5 years of age in South Sudan. Using anthropometric measurements, actual weights were compared with estimated weights from the Broselow tape and three age-based formulas. Mid-upper arm circumference was used to determine if each child was malnourished. Broselow accuracy was assessed by the percentage of measured weights falling into the same color zone as the predicted weight. For each method, accuracy was assessed by mean percentage error and percentage of predicted weights falling within 10% of actual weight. All data were analyzed by nutritional status subgroup. Only 10.7% of malnourished and 26.6% of nonmalnourished children had their actual weight fall within the Broselow color zone corresponding to their length. The Broselow method overestimated weight by a mean of 26.6% in malnourished children and 16.6% in nonmalnourished children (p < 0.001). Age-based formulas also overestimated weight, with mean errors ranging from 16.2% over actual weight (Advanced Pediatric Life Support in nonmalnourished children) to 70.9% over actual (Best Guess in severely malnourished children). The Broselow tape and age-based formulas selected for comparison were all markedly inaccurate in both the nonmalnourished and the malnourished populations studied, worsening with increasing malnourishment. Additional studies should explore appropriate methods of weight and dosage estimation for populations of low- and low-to-middle-income countries and regions with a high prevalence of malnutrition. © 2015 by the Society for Academic

  12. Dialects for the Stage: A Manual and Two Casette Tapes.

    ERIC Educational Resources Information Center

    Machlin, Evangeline

    This document contains a manual and two cassette tapes designed to help actors and actresses learn to speak various dialects. The tapes and the manual are arranged for the play-it-and-say-it method of dialect acquisition. The first three parts discuss the tapes and the manual in general, the dialect texts and dialect data, and the steps involved…

  13. Overview of Probe-based Storage Technologies

    NASA Astrophysics Data System (ADS)

    Wang, Lei; Yang, Ci Hui; Wen, Jing; Gong, Si Di; Peng, Yuan Xiu

    2016-07-01

    The current world is in the age of big data where the total amount of global digital data is growing up at an incredible rate. This indeed necessitates a drastic enhancement on the capacity of conventional data storage devices that are, however, suffering from their respective physical drawbacks. Under this circumstance, it is essential to aggressively explore and develop alternative promising mass storage devices, leading to the presence of probe-based storage devices. In this paper, the physical principles and the current status of several different probe storage devices, including thermo-mechanical probe memory, magnetic probe memory, ferroelectric probe memory, and phase-change probe memory, are reviewed in details, as well as their respective merits and weakness. This paper provides an overview of the emerging probe memories potentially for next generation storage device so as to motivate the exploration of more innovative technologies to push forward the development of the probe storage devices.

  14. Overview of Probe-based Storage Technologies.

    PubMed

    Wang, Lei; Yang, Ci Hui; Wen, Jing; Gong, Si Di; Peng, Yuan Xiu

    2016-12-01

    The current world is in the age of big data where the total amount of global digital data is growing up at an incredible rate. This indeed necessitates a drastic enhancement on the capacity of conventional data storage devices that are, however, suffering from their respective physical drawbacks. Under this circumstance, it is essential to aggressively explore and develop alternative promising mass storage devices, leading to the presence of probe-based storage devices. In this paper, the physical principles and the current status of several different probe storage devices, including thermo-mechanical probe memory, magnetic probe memory, ferroelectric probe memory, and phase-change probe memory, are reviewed in details, as well as their respective merits and weakness. This paper provides an overview of the emerging probe memories potentially for next generation storage device so as to motivate the exploration of more innovative technologies to push forward the development of the probe storage devices.

  15. Freeze Tape Casting of Functionally Graded Porous Ceramics

    NASA Technical Reports Server (NTRS)

    Sofie, Stephen W.

    2007-01-01

    Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

  16. Multilingual health education tapes project.

    PubMed

    Vryheid, R

    1992-01-01

    The success of Thailand's 1985 malaria education cassette tapes project motivated the Highland Development Program to produce tapes in 6 tribal languages on family planning, maternal and child health, nutrition, and disease prevention. Staff produced tapes using a drama or radio magazine format as a series of short features with music and sound effects. Scriptwriters consulted villagers, broadcasting professionals, research workers, and health officials to tailor messages to the various hill tribes. They tried to avoid conflict between traditional and modern concepts and to minimize distrust of government services. The scriptwriters used basically short, grammatically simple sentences, and colloquial Thai to simplify translation. The staff tried to recruit literate, adult, native speakers of the target languages with some experience in health education in their own languages. Obstacles encountered with translation included some languages used an uncommon alphabet or translators did not know their own alphabet. The program backtranslated the scripts to assure the accuracy of the messages and the appropriateness of the words used. Backtranslation revealed deficiencies in the translated messages. Altering the meaning of technical terms tended to be simple mistakes, words with multiple meanings, and exaggeration of problems and/or solutions. Translators also sometimes failed to adapt cultural ideas to those of their tribes. For example, some persons translated all possible misconceptions about a disease yet the tribes did not have all the misconceptions. As of early 1992, recording, pretesting, distribution, and follow up had not yet taken place. The staff should meet with a recording studio to coordinate production including technicians and translators identifying means to communicate. Staff should be aware of signs of poor translation which they may have missed earlier and surfaces during recording. Pretesting should occur among literate and illiterate members of

  17. A Meta-Analysis of the Taped Problems Intervention

    ERIC Educational Resources Information Center

    Kleinert, Whitney L.; Codding, Robin S.; Minami, Takuya; Gould, Kaitlin

    2018-01-01

    Taped problems is an intervention strategy for addressing mathematics fluency that has been evaluated in multiple single-case design studies. Although its efficacy has been supported in individual studies, no comprehensive quantitative synthesis has been conducted on taped problems. The purpose of this study was to synthesize the literature that…

  18. Metal hydride-based thermal energy storage systems

    DOEpatents

    Vajo, John J.; Fang, Zhigang

    2017-10-03

    The invention provides a thermal energy storage system comprising a metal-containing first material with a thermal energy storage density of about 1300 kJ/kg to about 2200 kJ/kg based on hydrogenation; a metal-containing second material with a thermal energy storage density of about 200 kJ/kg to about 1000 kJ/kg based on hydrogenation; and a hydrogen conduit for reversibly transporting hydrogen between the first material and the second material. At a temperature of 20.degree. C. and in 1 hour, at least 90% of the metal is converted to the hydride. At a temperature of 0.degree. C. and in 1 hour, at least 90% of the metal hydride is converted to the metal and hydrogen. The disclosed metal hydride materials have a combination of thermodynamic energy storage densities and kinetic power capabilities that previously have not been demonstrated. This performance enables practical use of thermal energy storage systems for electric vehicle heating and cooling.

  19. Ankle taping: support given by different materials.

    PubMed Central

    Capasso, G; Maffulli, N; Testa, V

    1989-01-01

    Three different adhesive and two non-adhesive tapes were used by three operators to assess the compressive action exerted on the ankle at the moment of strapping, during different phases of gait, and after some days of treatment in ten volunteers. Only the adhesive tapes were still able to prevent swelling after five days. They should be used if a prolonged compressive action is required. Images Figure 1 PMID:2517042

  20. Materials for Heated Head Automated Thermoplastic Tape Placement

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J.; Kinney, Megan C.; Cano, Roberto J.; Grimsley, Brian W.

    2012-01-01

    NASA Langley Research Center (LaRC) is currently pursuing multiple paths to develop out of autoclave (OOA) polymeric composite materials and processes. Polymeric composite materials development includes the synthesis of new and/or modified thermosetting and thermoplastic matrix resins designed for specific OOA processes. OOA processes currently under investigation include vacuum bag only (VBO) prepreg/composite fabrication, resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM) and heated head automated thermoplastic tape placement (HHATP). This paper will discuss the NASA Langley HHATP facility and capabilities and recent work on characterizing thermoplastic tape quality and requirements for quality part production. Samples of three distinct versions of APC-2 (AS4/PEEK) thermoplastic dry tape were obtained from two materials vendors, TENCATE, Inc. and CYTEC Engineered Materials** (standard grade and an experimental batch). Random specimens were taken from each of these samples and subjected to photo-microscopy and surface profilometry. The CYTEC standard grade of APC-2 tape had the most voids and splits and the highest surface roughness and/or waviness. Since the APC-2 tape is composed of a thermoplastic matrix, it offers the flexibility of reprocessing to improve quality, and thereby improve final quality of HHATP laminates. Discussions will also include potential research areas and future work that is required to advance the state of the art in the HHATP process for composite fabrication.

  1. A new method of measurement of tension on a moving magnetic tape

    NASA Technical Reports Server (NTRS)

    Kurtinaytis, A. K.; Lauzhinskas, Y. S.

    1973-01-01

    The possibility of no-contact measurement of the tension on a moving magnetic tape, assuming the tape is uniform, is discussed. A scheme for calculation of the natural frequency of transverse vibrations of magnetic tape is shown. Mathematical models are developed to show the relationships of the parameters. The method is applicable to the analysis of accurate tape feed mechanisms design.

  2. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit

    2013-07-09

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  3. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    DOEpatents

    Goyal, Amit [Knoxville, TN

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  4. [Efficacy of the application of kinesio tape in patients with stroke].

    PubMed

    Ortiz-Ramirez, J; Perez-De la Cruz, S

    2017-02-16

    To review the effects achieved by the kinesio tape in patients with stroke in scientific studies published on date and to discuss these findings may be of interest to neurology. An exhaustive search in the main scientific databases using keywords such as kinesio tape, kinesiotaping, musculoskeletal tape, taping medical concept was carried out. Citations of selected articles and scientific papers published on the website of the Spanish Association of Neuromuscular Bandage were analyzed. Experimental, quasi-experimental, clinical trials and case studies published were used, without limit date, with therapeutical treatment purpose provide important results. Eight articles have met the inclusion criteria. There are eight studies that examine the effect on kinesio tape on lower limb, gait and balance in this kind of therapy, even upper limb and swallowing problems that these patients could present. The kinesio tape in neurological patients can be a complementary technique that empirically provides benefits. However, better methodological quality studies demonstrating the effects attributed to him are still needed.

  5. Recovery of recordings from heat damaged magnetic tapes

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  6. Kinesiology tape mediates soccer-simulated and local peroneal fatigue in soccer players.

    PubMed

    Farquharson, Claire; Greig, Matt

    2017-01-01

    To investigate the efficacy of kinesiology taping in mediating the influence of fatigue on ankle sprain risk, 12 male soccer players completed single-leg dynamic balance trials pre- and post-exercise (soccer-specific protocol, isokinetic ankle inversion/eversion protocol) in each of three counter-balanced taping conditions (no tape, zinc oxide tape ZO, kinesiology tape KT). Balance was quantified as the overall stability index (OSI) and directional stability indices of platform deflection. Soccer-specific fatigue only increased OSI in the no tape condition (p = 0.03), with ZO and KT trials negating a fatigue affect. Localized fatigue increased OSI in the no tape (p = 0.01) and ZO (p = 0.05) trials, with no increase in the KT trial. A similar pattern was observed in medio-lateral and anterio-posterior balance indices. KT mediates soccer-simulated and local peroneal fatigue, with practical implications for epidemiological observations of increased injury risk during the latter stages of match play.

  7. Software Computes Tape-Casting Parameters

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2003-01-01

    Tcast2 is a FORTRAN computer program that accelerates the setup of a process in which a slurry containing metal particles and a polymeric binder is cast, to a thickness regulated by a doctor blade, onto fibers wound on a rotating drum to make a green precursor of a metal-matrix/fiber composite tape. Before Tcast2, setup parameters were determined by trial and error in time-consuming multiple iterations of the process. In Tcast2, the fiber architecture in the final composite is expressed in terms of the lateral distance between fibers and the thickness-wise distance between fibers in adjacent plies. The lateral distance is controlled via the manner of winding. The interply spacing is controlled via the characteristics of the slurry and the doctor-blade height. When a new combination of fibers and slurry is first cast and dried to a green tape, the shrinkage from the wet to the green condition and a few other key parameters of the green tape are measured. These parameters are provided as input to Tcast2, which uses them to compute the doctor-blade height and fiber spacings needed to obtain the desired fiber architecture and fiber volume fraction in the final composite.

  8. Contact Analog/Compressed Symbology Heading Tape Assessment

    NASA Technical Reports Server (NTRS)

    Shively, R. Jay; Atencio, Adolph; Turpin, Terry; Dowell, Susan

    2002-01-01

    A simulation assessed the performance, handling qualities and workload associated with a contact-analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a screen-fixed, compressed heading tape. Six pilots, four active duty Army Aviators and two civilians flew three ADS-33 maneuvers and a traffic pattern in the Ames Vertical Motion Simulation facility. Small, but statistically significant advantages were found for the compressed symbology for handling qualities, workload, and some of the performance measures. It should be noted however that the level of performance and handling qualities for both symbology sets fell within the acceptable tolerance levels. Both symbology sets yield satisfactory handling qualities and performance in velocity stabilization mode and adequate handling qualities in the automatic flight control mode. Pilot comments about the contact analog symbology highlighted the lack of useful rate of change information in the heading tape and "blurring" due to the rapid movement of the heading tape. These issues warrant further study. Care must be taken in interpreting the operational significance of these results. The symbology sets yielded categorically similar data, i.e., acceptable handling qualities and adequate performance, so while the results point to the need for further study, their operational significance has yet to be determined.

  9. Paper‐Based Electrodes for Flexible Energy Storage Devices

    PubMed Central

    Yao, Bin; Zhang, Jing; Kou, Tianyi; Song, Yu; Liu, Tianyu

    2017-01-01

    Paper‐based materials are emerging as a new category of advanced electrodes for flexible energy storage devices, including supercapacitors, Li‐ion batteries, Li‐S batteries, Li‐oxygen batteries. This review summarizes recent advances in the synthesis of paper‐based electrodes, including paper‐supported electrodes and paper‐like electrodes. Their structural features, electrochemical performances and implementation as electrodes for flexible energy storage devices including supercapacitors and batteries are highlighted and compared. Finally, we also discuss the challenges and opportunity of paper‐based electrodes and energy storage devices. PMID:28725532

  10. Integration of altitude and airspeed information into a primary flight display via moving-tape formats: Evaluation during random tracking task

    NASA Technical Reports Server (NTRS)

    Abbott, Terence S.; Nataupsky, Mark; Steinmetz, George G.

    1987-01-01

    A ground-based aircraft simulation study was conducted to determine the effects on pilot preference and performance of integrating airspeed and altitude information into an advanced electronic primary flight display via moving-tape (linear moving scale) formats. Several key issues relating to the implementation of moving-tape formats were examined in this study: tape centering, tape orientation, and trend information. The factor of centering refers to whether the tape was centered about the actual airspeed or altitude or about some other defined reference value. Tape orientation refers to whether the represented values are arranged in descending or ascending order. Two pilots participated in this study, with each performing 32 runs along seemingly random, previously unknown flight profiles. The data taken, analyzed, and presented consisted of path performance parameters, pilot-control inputs, and electrical brain response measurements.

  11. Mirror-touch and ticker tape experiences in synesthesia

    PubMed Central

    Chun, Charlotte A.; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2–4%) and sequence-space synesthesia (9–14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes. PMID

  12. An Experimental Investigation of Damaged Arresting Gear Tapes for the Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mason, Angela J.

    1999-01-01

    An experimental investigation was performed on damaged arresting gear tapes at the Langley Aircraft Landing Dynamics Facility. The arrestment system uses five pairs of tapes to bring the test carriage to a halt. The procedure used to determine when to replace the tapes consists of a close evaluation of each of the 10 tapes after each run. During this evaluation, each tape is examined thoroughly and any damage observed on the tape is recorded. If the damaged tape does not pass the inspection, the tape is replaced with a new one. For the past 13 years, the most commonly seen damage types are edge fray damage and transverse damage. Tests were conducted to determine the maximum tensile strength of a damaged arresting gear tape specimen. The data indicate that tapes exhibiting transverse damage can withstand higher loads than tapes with edge fray damage.

  13. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an... dissolve surface skin oil or adhesive tape. (b) Classification. Class I (general controls). The device is...

  14. Enhanced recoverable energy storage density and high efficiency of SrTiO3-based lead-free ceramics

    NASA Astrophysics Data System (ADS)

    Yang, Haibo; Yan, Fei; Lin, Ying; Wang, Tong

    2017-12-01

    In this study, (1-x)SrTiO3-x(Bi0.48La0.02Na0.48Li0.02Ti0.98Zr0.02O3) [(1-x)ST-xBLNLTZ] lead-free ceramics with x = 0-0.4 were designed and fabricated using the tape casting process and the subsequent conventional solid-state sintering method. The (1-x)ST-xBLNLTZ ceramics are characterized by the excellent frequency stability of the dielectric constant, large maximum polarization (Pmax), low remnant polarization (Pr), and slim polarization-electric field (P-E) loops. For the composition of x = 0.4, Pmax is increased to 30.35 μC/cm2, 3.82 times higher than that of pure SrTiO3 (7.95 μC/cm2). The breakdown strength is larger than 200 kV/cm for all the samples. The sample with x = 0.1 exhibits a high recoverable energy storage density (Wrec) of 2.59 J/cm3 and a high energy storage efficiency (η) of 85% simultaneously. The results demonstrate that the (1-x)ST-xBLNLTZ ceramics are promising lead-free materials for high energy storage applications.

  15. Online Data Handling and Storage at the CMS Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andre, J. M.; et al.

    2015-12-23

    During the LHC Long Shutdown 1, the CMS Data Acquisition (DAQ) system underwent a partial redesign to replace obsolete network equipment, use more homogeneous switching technologies, and support new detector back-end electronics. The software and hardware infrastructure to provide input, execute the High Level Trigger (HLT) algorithms and deal with output data transport and storage has also been redesigned to be completely file- based. All the metadata needed for bookkeeping are stored in files as well, in the form of small documents using the JSON encoding. The Storage and Transfer System (STS) is responsible for aggregating these files produced bymore » the HLT, storing them temporarily and transferring them to the T0 facility at CERN for subsequent offline processing. The STS merger service aggregates the output files from the HLT from ~62 sources produced with an aggregate rate of ~2GB/s. An estimated bandwidth of 7GB/s in concurrent read/write mode is needed. Furthermore, the STS has to be able to store several days of continuous running, so an estimated of 250TB of total usable disk space is required. In this article we present the various technological and implementation choices of the three components of the STS: the distributed file system, the merger service and the transfer system.« less

  16. Effects of Kinesio taping and exercise on forward head posture.

    PubMed

    Shih, Hsu-Sheng; Chen, Shu-Shi; Cheng, Su-Chun; Chang, Hsun-Wen; Wu, Pei-Rong; Yang, Jin-Shiou; Lee, Yi-Shuang; Tsou, Jui-Yi

    2017-01-01

    Little is known about the effects of Kinesio taping and therapeutic exercise on correcting forward head posture. To compare Kinesio taping versus therapeutic exercise for forward head posture on static posture, dynamic mobility and functional outcomes. Sixty subjects (31 women, 29 men) with forward head postures participated in this study. They were randomly assigned to either one of the three groups: (1) exercise group (n = 20), (2) taping group (n = 20), and (3) control groups (n = 20). The horizontal forward displacement (HFD) between ear lobe and acromion process, upper cervical and lower cervical angle (UCA, LCA), active range of motion (AROM) of cervical spine, and neck disability index (NDI) were measured before and after a 5-week intervention, and a 2-week follow-up. Data were analyzed by means of a mixed design repeated-measures ANOVA. Both taping and exercise groups showed significant improvements in HFD compared with the control group at post-treatment and follow-up. Compared with the control group, the exercise group exhibited significant improvements in the LCA and the side bending AROM at post-treatment. Both Kinesio taping and therapeutic exercise improve forward head posture after intervention and a 2-week follow-up. The effectiveness of therapeutic exercise is better than taping.

  17. Kinesio Taping effects on knee extension force among soccer players.

    PubMed

    Serra, Maysa V G B; Vieira, Edgar R; Brunt, Denis; Goethel, Márcio F; Gonçalves, Mauro; Quemelo, Paulo R V

    2015-01-01

    Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. To evaluate the effects of KT on knee extension force in soccer players. This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension.

  18. Effects of kinesio tape to reduce hand edema in acute stroke.

    PubMed

    Bell, Alison; Muller, Melissa

    2013-01-01

    The purpose of the study was to evaluate the effi cacy of Kinesio Tape (Kinesio USA, Albequerque, NM) for reducing hand edema in individuals with hemiplegia post stroke. Seventeen individuals who experienced acute stroke were screened for visual signs of edema and were randomly assigned to experimental and control groups. The experimental group received Kinesio Tape that was applied to hand and forearm for 6 days in combination with standard therapy; the control group received standard therapy. Blinded raters assessed edema reduction via circumferential measurements. Application of Kinesio Tape did not result in statistically signifi cant reduction in edema. Large and medium effect sizes were seen for edema reduction at the metacarpophalangeal and wrist joints, respectively, with Kinesio Tape. Further research is warranted to investigate the utility of Kinesio Tape in edema reduction.

  19. Induction Bonding of Prepreg Tape and Titanium Foil

    NASA Technical Reports Server (NTRS)

    Messier, Bernadette C.; Hinkley, Jeffrey A.; Johnston, Norman J.

    1998-01-01

    Hybrid structural laminates made of titanium foil and carbon fiber reinforced polymer composite offer a potential for improved performance in aircraft structural applications. To obtain information needed for the automated fabrication of hybrid laminates, a series of bench scale tests were conducted of the magnetic induction bonding of titanium foil and thermoplastic prepreg tape. Foil and prepreg specimens were placed in the gap of a toroid magnet mounted in a bench press. Several magnet power supplies were used to study power at levels from 0.5 to 1.75 kW and frequencies from 50 to 120 kHz. Sol-gel surface-treated titanium foil, 0.0125 cm thick, and PIXA/IM7 prepreg tape were used in several lay-up configurations. Data were obtained on wedge peel bond strength, heating rate, and temperature ramp over a range of magnet power levels and frequencies at different "power-on" times for several magnet gap dimensions. These data will be utilized in assessing the potential for automated processing. Peel strengths of foil-tape bonds depended on the maximum temperature reached during heating and on the applied pressure. Maximum peel strengths were achieved at 1.25kW and 8OkHz. Induction heating of the foil appears to be capable of good bonding up to 10 plies of tape. Heat transfer calculations indicate that a 20-40 C temperature difference exists across the tape thickness during heat-up.

  20. Report of the Tape Recorder Action Plan Committee, 21 March 1972

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A NASA/AF Tape Recorder Action Plan Committee was formed in January 1972 to investigate tape recorder problems and to recommend an action plan to NASA management. The committee collected data on tape recorder failure history, pinpointed problem areas, discussed needed technical and management changes, and proposed an action plan for the recommended approaches.

  1. Interpretation of the human skin biotribological behaviour after tape stripping.

    PubMed

    Pailler-Mattei, C; Guerret-Piécourt, C; Zahouani, H; Nicoli, S

    2011-07-06

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ(0), and the second term depending on the electric shear strength, τ(elec). The experimental results allowed to estimate a numerical value of the electric shear strength τ(elec). Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption.

  2. Interpretation of the human skin biotribological behaviour after tape stripping

    PubMed Central

    Pailler-Mattei, C.; Guerret-Piécourt, C.; Zahouani, H.; Nicoli, S.

    2011-01-01

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ0, and the second term depending on the electric shear strength, τelec. The experimental results allowed to estimate a numerical value of the electric shear strength τelec. Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption. PMID:21227961

  3. Tools for applying lead tape to flat conductor cabling for chemical stripping

    NASA Technical Reports Server (NTRS)

    Angele, W.

    1969-01-01

    Two tools facilitate chemical stripping of insulation on flat conductor cabling. A tape pressing tool and a taping fixture apply adhesive lead tape with the proper amount of pressure to protect the remaining insulation from the chemical stripping solution.

  4. Archival storage solutions for PACS

    NASA Astrophysics Data System (ADS)

    Chunn, Timothy

    1997-05-01

    While they are many, one of the inhibitors to the wide spread diffusion of PACS systems has been robust, cost effective digital archive storage solutions. Moreover, an automated Nearline solution is key to a central, sharable data repository, enabling many applications such as PACS, telemedicine and teleradiology, and information warehousing and data mining for research such as patient outcome analysis. Selecting the right solution depends on a number of factors: capacity requirements, write and retrieval performance requirements, scaleability in capacity and performance, configuration architecture and flexibility, subsystem availability and reliability, security requirements, system cost, achievable benefits and cost savings, investment protection, strategic fit and more.This paper addresses many of these issues. It compares and positions optical disk and magnetic tape technologies, which are the predominant archive mediums today. Price and performance comparisons will be made at different archive capacities, plus the effect of file size on storage system throughput will be analyzed. The concept of automated migration of images from high performance, high cost storage devices to high capacity, low cost storage devices will be introduced as a viable way to minimize overall storage costs for an archive. The concept of access density will also be introduced and applied to the selection of the most cost effective archive solution.

  5. FPGA-based prototype storage system with phase change memory

    NASA Astrophysics Data System (ADS)

    Li, Gezi; Chen, Xiaogang; Chen, Bomy; Li, Shunfen; Zhou, Mi; Han, Wenbing; Song, Zhitang

    2016-10-01

    With the ever-increasing amount of data being stored via social media, mobile telephony base stations, and network devices etc. the database systems face severe bandwidth bottlenecks when moving vast amounts of data from storage to the processing nodes. At the same time, Storage Class Memory (SCM) technologies such as Phase Change Memory (PCM) with unique features like fast read access, high density, non-volatility, byte-addressability, positive response to increasing temperature, superior scalability, and zero standby leakage have changed the landscape of modern computing and storage systems. In such a scenario, we present a storage system called FLEET which can off-load partial or whole SQL queries to the storage engine from CPU. FLEET uses an FPGA rather than conventional CPUs to implement the off-load engine due to its highly parallel nature. We have implemented an initial prototype of FLEET with PCM-based storage. The results demonstrate that significant performance and CPU utilization gains can be achieved by pushing selected query processing components inside in PCM-based storage.

  6. Generation and physical characteristics of the ERTS MSS system corrected computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1973-01-01

    The generation and format are discussed of the ERTS system corrected multispectral scanner computer compatible tapes. The discussion includes spacecraft sensors, scene characteristics, data transmission, and conversion of data to computer compatible tapes at the NASA Data Processing Facility. Geometeric and radiometric corrections, tape formats, and the physical characteristics of the tapes are also included.

  7. The effective resistance between twisted superconducting filaments in tapes

    NASA Astrophysics Data System (ADS)

    Takács, S.; Iwakuma, M.; Funaki, K.

    2001-05-01

    We consider two mechanisms, which influence the effective resistance between crossing strands on flat cables or filaments in twisted tapes. The one-layer classical Rutherford-type cable and the tapes with twisted BSCCO filaments in silver matrix are taken as analogous cases. The amount of the matrix between strands or filaments increases the effective conductance compared with the direct current paths (determined by the touching area of the filaments). The increase factor is about two and can easily be suppressed by other effects, like the contact resistance between the superconductor and the matrix. The second mechanism is due to the existence of induced voltage between any points of crossing filaments. This leads to an additional effective conductance, proportional to the square of the total number of filaments. Both effects are not very important for isotropic superconductors, but due to the strong anisotropy of critical parameters they can dominate for high temperature superconductors. The first one may partially compensate the influence of the usually weaker critical current density perpendicular to the tape. The contribution due to the second effect can explain the higher resistivity of the matrix in BSCCO tapes compared with pure silver. It seems that to obtain low AC coupling losses in BSCCO tapes, structures with small filament number are required.

  8. Surreptitious Taping: The Arguments for and the Ethics against.

    ERIC Educational Resources Information Center

    Cooper, Thomas W.

    Much discussion within media ethics has focused on the acceptability of surreptitious tape recording of news sources by media professionals. The most common legal and social arguments supporting secret taping assert that recorders "hear" and "remember" better, are expedient and practical, protect against libel suits, provide…

  9. REDUCED COST SEWER PIPE RELINING USING ULTRASONIC TAPE LAMINATION - PHASE II

    EPA Science Inventory

    During the Phase I program, Foster-Miller developed techniques based on Ultrasonic Tape Lamination (UTL) for joining of plasticized PVC sewer pipe liner. This effort was undertaken in response to a need for environmentally sound and cost-effective methods for rehabilitation of...

  10. Ankle Spatting Compared to Bracing or Taping during Maximal-Effort Sprint Drills

    PubMed Central

    REUTER, GRANT D; DAHL, ANGELA R; SENCHINA, DAVID S

    2011-01-01

    The purpose of this study was to compare the influences of 4 ankle conditions (no support, bracing, taping, taping + spatting; all in football cleats) during 2 maximal-effort field drills (40-yd dash and 34-yd cutting drill) on perceptions of comfort and stability and performance outcomes. Fourteen young adult males participated. Subjects’ perceptions of comfort and stability were assessed by visual analogue scales after each drill for each ankle condition. Time-to-completion and post-completion heart rate were recorded. For both drills, significant differences in comfort perception were found such that subjects perceived no support as equivocal to bracing but more comfortable than either taping or spatting + taping. Stability results differed by drill. For the dash, significant differences in stability perception were found such that subjects perceived no support as equivocal to bracing but less stable than either taping or spatting + taping. By contrast, for the cutting drill significant differences in stability perception were found such that subjects perceived their ankles as less stable during the no support condition as compared to all 3 other conditions. Generally, bracing was perceived as equivocal to all 3 other conditions for comfort and stability. There were no significant differences in time-to-completion or heart rate for any comparison. Compared to bracing or taping, spatting + taping (a) did not influence performance time in explosive/sprint-type drills, (b) was perceived as equivalent to taping alone in terms of ankle comfort and stability, and (c) was perceived as equivalent to bracing in terms of stability but not comfort. PMID:27478530

  11. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grin, A.; Lstiburek, J.

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues weremore » discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.« less

  12. Kinesio Taping effects on knee extension force among soccer players

    PubMed Central

    Serra, Maysa V. G. B.; Vieira, Edgar R.; Brunt, Denis; Goethel, Márcio F.; Gonçalves, Mauro; Quemelo, Paulo R. V.

    2015-01-01

    Background: Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. Objective: To evaluate the effects of KT on knee extension force in soccer players. Method: This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. Results: There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. Conclusion: KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension. PMID:25789557

  13. Effects of Corrective Taping on Balance and Gait in Patients With Hallux Valgus.

    PubMed

    Gur, Gozde; Ozkal, Ozden; Dilek, Burcu; Aksoy, Songul; Bek, Nilgun; Yakut, Yavuz

    2017-05-01

    Taping is an effective temporary therapy for improving hallux valgus (HV) in adults. Although HV has been demonstrated to impair postural balance, there is a lack of information about how corrective taping affects balance and gait patterns in adults with HV deformity. Eighteen middle-aged female patients (average age, 53.5 years) with HV were included. Corrective tape was applied to correct HV angulation. A series of balance and gait stability tests were performed before applying tape and 1 hour after the tape was applied with a Balance Master computerized posturography device. The study involved the following tests: modified clinical test of sensory interaction and balance (mCTSIB), unilateral stance (US), limit of stability (LoS), step up/over (SUO), and walk across (WA) tests. No significant difference was found between the no-tape and taped condition in the static balance mCTSIB and US tests ( P > .05). The taping intervention resulted in significant improvement in the dynamic balance measures for the LoS test's backward reaction time and left maximum excursion ( P < .05), a significantly higher impact index bilaterally in the SUO assessment ( P < .05), and an increase in step width mean and variability in the WA test ( P < .05). Taping for correcting HV angulation had negative acute effects on dynamic balance in the SUO and WA tests and positive effects in the LoS test. Corrective taping, although a form of conservative treatment for hallux valgus, has been insufficiently studied in terms of effects on balance. Our results show that taping, as an acute effect, may impair balance in middle-aged adults when walking or ascending and descending stairs.

  14. Performance Study of Salt Cavern Air Storage Based Non-Supplementary Fired Compressed Air Energy Storage System

    NASA Astrophysics Data System (ADS)

    Chen, Xiaotao; Song, Jie; Liang, Lixiao; Si, Yang; Wang, Le; Xue, Xiaodai

    2017-10-01

    Large-scale energy storage system (ESS) plays an important role in the planning and operation of smart grid and energy internet. Compressed air energy storage (CAES) is one of promising large-scale energy storage techniques. However, the high cost of the storage of compressed air and the low capacity remain to be solved. This paper proposes a novel non-supplementary fired compressed air energy storage system (NSF-CAES) based on salt cavern air storage to address the issues of air storage and the efficiency of CAES. Operating mechanisms of the proposed NSF-CAES are analysed based on thermodynamics principle. Key factors which has impact on the system storage efficiency are thoroughly explored. The energy storage efficiency of the proposed NSF-CAES system can be improved by reducing the maximum working pressure of the salt cavern and improving inlet air pressure of the turbine. Simulation results show that the electric-to-electric conversion efficiency of the proposed NSF-CAES can reach 63.29% with a maximum salt cavern working pressure of 9.5 MPa and 9 MPa inlet air pressure of the turbine, which is higher than the current commercial CAES plants.

  15. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, Melton E.

    1984-01-01

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  16. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, M.E.

    1982-09-03

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  17. DPM — efficient storage in diverse environments

    NASA Astrophysics Data System (ADS)

    Hellmich, Martin; Furano, Fabrizio; Smith, David; Brito da Rocha, Ricardo; Álvarez Ayllón, Alejandro; Manzi, Andrea; Keeble, Oliver; Calvet, Ivan; Regala, Miguel Antonio

    2014-06-01

    Recent developments, including low power devices, cluster file systems and cloud storage, represent an explosion in the possibilities for deploying and managing grid storage. In this paper we present how different technologies can be leveraged to build a storage service with differing cost, power, performance, scalability and reliability profiles, using the popular storage solution Disk Pool Manager (DPM/dmlite) as the enabling technology. The storage manager DPM is designed for these new environments, allowing users to scale up and down as they need it, and optimizing their computing centers energy efficiency and costs. DPM runs on high-performance machines, profiting from multi-core and multi-CPU setups. It supports separating the database from the metadata server, the head node, largely reducing its hard disk requirements. Since version 1.8.6, DPM is released in EPEL and Fedora, simplifying distribution and maintenance, but also supporting the ARM architecture beside i386 and x86_64, allowing it to run the smallest low-power machines such as the Raspberry Pi or the CuBox. This usage is facilitated by the possibility to scale horizontally using a main database and a distributed memcached-powered namespace cache. Additionally, DPM supports a variety of storage pools in the backend, most importantly HDFS, S3-enabled storage, and cluster file systems, allowing users to fit their DPM installation exactly to their needs. In this paper, we investigate the power-efficiency and total cost of ownership of various DPM configurations. We develop metrics to evaluate the expected performance of a setup both in terms of namespace and disk access considering the overall cost including equipment, power consumptions, or data/storage fees. The setups tested range from the lowest scale using Raspberry Pis with only 700MHz single cores and a 100Mbps network connections, over conventional multi-core servers to typical virtual machine instances in cloud settings. We evaluate the

  18. Textured substrate tape and devices thereof

    DOEpatents

    Goyal, Amit

    2006-08-08

    A method for forming a sharply biaxially textured substrate, such as a single crystal substrate, includes the steps of providing a deformed metal substrate, followed by heating above the secondary recrystallization temperature of the deformed substrate, and controlling the secondary recrystallization texture by either using thermal gradients and/or seeding. The seed is selected to shave a stable texture below a predetermined temperature. The sharply biaxially textured substrate can be formed as a tape having a length of 1 km, or more. Epitaxial articles can be formed from the tapes to include an epitaxial electromagnetically active layer. The electromagnetically active layer can be a superconducting layer.

  19. String and Sticky Tape Experiments.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  20. Helical tape forming device

    NASA Technical Reports Server (NTRS)

    Bush, J. E.; Cole, P. T.

    1969-01-01

    Using a device that is not limited to a minimum thickness or width-to-thickness ratio, a very thin metal tape or ribbon is formed into a continuous flat wound helical coil. The device imparts the desired circular shape by squeeze rolling it with an unequal force across its width.

  1. Sixth Goddard Conference on Mass Storage Systems and Technologies Held in Cooperation with the Fifteenth IEEE Symposium on Mass Storage Systems

    NASA Technical Reports Server (NTRS)

    Kobler, Benjamin (Editor); Hariharan, P. C. (Editor)

    1998-01-01

    This document contains copies of those technical papers received in time for publication prior to the Sixth Goddard Conference on Mass Storage Systems and Technologies which is being held in cooperation with the Fifteenth IEEE Symposium on Mass Storage Systems at the University of Maryland-University College Inn and Conference Center March 23-26, 1998. As one of an ongoing series, this Conference continues to provide a forum for discussion of issues relevant to the management of large volumes of data. The Conference encourages all interested organizations to discuss long term mass storage requirements and experiences in fielding solutions. Emphasis is on current and future practical solutions addressing issues in data management, storage systems and media, data acquisition, long term retention of data, and data distribution. This year's discussion topics include architecture, tape optimization, new technology, performance, standards, site reports, vendor solutions. Tutorials will be available on shared file systems, file system backups, data mining, and the dynamics of obsolescence.

  2. A system for the input and storage of data in the Besm-6 digital computer

    NASA Technical Reports Server (NTRS)

    Schmidt, K.; Blenke, L.

    1975-01-01

    Computer programs used for the decoding and storage of large volumes of data on the the BESM-6 computer are described. The following factors are discussed: the programming control language allows the programs to be run as part of a modular programming system used in data processing; data control is executed in a hierarchically built file on magnetic tape with sequential index storage; and the programs are not dependent on the structure of the data.

  3. Does Kinesiology tape counter exercise-related impairments of balance in the elderly?

    PubMed

    Hosp, Simona; Csapo, Robert; Heinrich, Dieter; Hasler, Michael; Nachbauer, Werner

    2018-05-01

    Maintaining balance is an essential requirement for the performance of daily tasks and sporting activities, particularly in older adults to prevent falls and associated injuries. Kinesiology tape has gained great popularity in sports and is frequently used as a tool for performance enhancement. However, there is little research investigating its influence on balance. The purpose of this study was to evaluate the effect of Kinesiology tape on dynamic balance, postural stability and knee proprioception after physical activity in healthy, older adults. Twelve physically active, healthy men aged 63-77 years performed the test on two separate days, with and without Kinesiology tape at the knee joint (prospective intervention with cross-over design). Dynamic balance during an obstacle-crossing task, postural stability in a single-leg stance test, and knee joint position sense as a measure of proprioception were examined before and after 30 min of downhill walking on a treadmill. The influences of taping condition and physical activity on all parameters were statistically tested using factorial ANOVAs. Factorial ANOVA revealed significant time × taping condition interaction effects on all performance parameters (p < 0.05), indicating that the exercise-related changes in dynamic balance, postural stability and knee proprioception differed between the two taping conditions. The deterioration of performance was always greater when no tape was used. This study demonstrated that physical exercise significantly deteriorated dynamic balance, postural stability and knee proprioception in older men. These effects can be attenuated through the usage of Kinesiology tape. By preventing exercise-related impairments of balance, Kinesiology tape might help reduce the risk of sports-associated falls and associated injuries. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.

    2000-01-01

    Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

  5. Application of Kinesio Taping method for newborn swallowing difficultly

    PubMed Central

    Lin, Chien-Lin; Wu, Wei-Ting; Chang, Ke-Vin; Lin, Hong-Yi; Chou, Li-Wei

    2016-01-01

    Abstract Background: Preterm infants are at an increased risk of sucking problems, swallowing difficulty, and poor nourishment. During the neonatal period, the neurobehavioral organization of a preterm baby is poor compared with that of appropriate gestational age infants. Kinesio Taping has been widely used for edema control, joint protection, and proprioception training. With the help of augmentation of the sensory input for muscle facilitation and inhibition through tapping, the coordination of the target muscle groups can be improved. Until now, no research is available on the use of Kinesio Taping for the swallowing difficulty of infant. Methods: We reported a preterm infant suffering from brain edema at birth and swallowing difficultly until 40 weeks. The swallowing reflex was delayed. Moreover, lip closure and rooting reflex combined with the dysfunction grade of jaw movement were poor. We performed KT methods on the baby under the theory of the direction of the tape for facilitate or inhibit the muscle. Result: After the Kinesio Taping treatment, the sucking function was improved with good lip closure.One week later, the baby was discharged without the use of an oral gastric tube. Conclusion: Kinesio Taping contributed significantly to the improvement of impaired sucking and swallowing and could be implemented as a regular rehabilitative approach for infants suffering from these difficulties. PMID:27495080

  6. Data storage systems technology for the Space Station era

    NASA Technical Reports Server (NTRS)

    Dalton, John; Mccaleb, Fred; Sos, John; Chesney, James; Howell, David

    1987-01-01

    The paper presents the results of an internal NASA study to determine if economically feasible data storage solutions are likely to be available to support the ground data transport segment of the Space Station mission. An internal NASA effort to prototype a portion of the required ground data processing system is outlined. It is concluded that the requirements for all ground data storage functions can be met with commercial disk and tape drives assuming conservative technology improvements and that, to meet Space Station data rates with commercial technology, the data will have to be distributed over multiple devices operating in parallel and in a sustained maximum throughput mode.

  7. Effect of sintering temperature on flexural properties of alumina fiber-reinforced, alumina-based ceramics prepared by tape casting technique.

    PubMed

    Tanimoto, Yasuhiro; Nemoto, Kimiya

    2006-01-01

    The purpose of this study was to investigate the effect of sintering temperature on flexural properties of an alumina fiber-reinforced, alumina-based ceramic (alumina-fiber/alumina composite) prepared by a tape casting technique. The alumina-based ceramic used a matrix consisting of 60 wt% Al(2)O(3) powder and 40 wt% SiO(2)-B(2)O(3) glass powder with the following composition in terms of wt%: 33 SiO(2), 32 B(2)O(3), 20 CaO, and 15 MgO. Prepreg sheets of alumina-fiber/alumina composite in which uniaxial aligned alumina fibers were infiltrated with the alumina-based matrix were fabricated continuously using a tape casting technique employing a doctor blade system. Four sintering temperatures were investigated: 900 degrees C, 1000 degrees C, 1100 degrees C, and 1200 degrees C, all for 4 hours under atmospheric pressure in a furnace. The surface of the alumina-fiber/alumina composite after sintering was observed with a field-emission scanning electron microscope (FE-SEM). A three-point bending test was carried out to measure the flexural strength and modulus of alumina-fiber/alumina composite specimens. In addition, sintered alumina fiber was characterized by X-ray diffraction (XRD). FE-SEM observation showed that alumina-fiber/alumina composite was confirmed to be densely sintered for all sintering temperatures. Three-point bending measurement revealed that alumina-fiber/alumina composite produced at sintering temperatures of 1100 degrees C and 1200 degrees C exhibit flexural strengths lower than those of alumina-fiber/alumina composite produced at sintering temperatures of 900 degrees C and 1000 degrees C; alumina-fiber/alumina composite produced at sintering temperatures of 1100 degrees C and 1200 degrees C exhibit flexural moduli lower than that of alumina-fiber/alumina composite produced at a sintering temperature of 1000 degrees C. Additional XRD pattern of alumina fiber indicated that with increasing sintering temperature, the crystallographic structure of gamma

  8. One-step Tape Casting of Composites via Slurry on Fiber

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2001-01-01

    A process by which metal matrix composites can be made was presented. The process involves putting a powder slurry on fibers to make a precursor green tape. These green tapes are cut, stacked and hot pressed to form the fully dense composite. A computer program was presented which enables complete quantification and control of the process. Once some easily obtained properties of the slurry and its behavior are determined (such as the shrinkage from the wet to green state, and the density of the green tape) modification of the fiber spacing and blade height give the maker precise control of fiber volume fraction, and fiber architecture in the composite. The process was shown to be accurate and flexible through the production of a wide variety of volume fraction fiber composites made from a wide variety of fibers and powders. The most time consuming step of the tape casting process (other than hot pressing) was winding the fiber on the drum. The tape casting techniques developed resulted in high quality metal matrix composites, with ultimate tensile strength in the range of 215 ksi (1477 MPa), a strain at failure of 1.15 percent, and in fatigue at room temperature 0 to 120 ksi, n = 0.3 Hz, a 4-ply Ti-24Al-11Nb/SCS-6, 32 vol% fiber tape cast composite lasted 202,205 cycles with a maximum strain on the 100th cycle of 0.43 percent.

  9. 40 CFR Table 8 to Subpart U of... - Summary of Compliance Alternative Requirements for the Back-End Process Provisions

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Requirements for the Back-End Process Provisions 8 Table 8 to Subpart U of Part 63 Protection of Environment...: Group I Polymers and Resins Pt. 63, Subpt. U, Table 8 Table 8 to Subpart U of Part 63—Summary of... be monitored Requirements Compliance Using Stripping Technology, Demonstrated through Periodic...

  10. 40 CFR Table 8 to Subpart U of... - Summary of Compliance Alternative Requirements for the Back-End Process Provisions

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Requirements for the Back-End Process Provisions 8 Table 8 to Subpart U of Part 63 Protection of Environment...: Group I Polymers and Resins Pt. 63, Subpt. U, Table 8 Table 8 to Subpart U of Part 63—Summary of... be monitored Requirements Compliance Using Stripping Technology, Demonstrated through Periodic...

  11. 40 CFR Table 8 to Subpart U of... - Summary of Compliance Alternative Requirements for the Back-End Process Provisions

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Requirements for the Back-End Process Provisions 8 Table 8 to Subpart U of Part 63 Protection of Environment...: Group I Polymers and Resins Pt. 63, Subpt. U, Table 8 Table 8 to Subpart U of Part 63—Summary of... be monitored Requirements Compliance Using Stripping Technology, Demonstrated through Periodic...

  12. 40 CFR Table 8 to Subpart U of... - Summary of Compliance Alternative Requirements for the Back-End Process Provisions

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Requirements for the Back-End Process Provisions 8 Table 8 to Subpart U of Part 63 Protection of Environment...: Group I Polymers and Resins Pt. 63, Subpt. U, Table 8 Table 8 to Subpart U of Part 63—Summary of... be monitored Requirements Compliance Using Stripping Technology, Demonstrated through Periodic...

  13. 40 CFR Table 8 to Subpart U of... - Summary of Compliance Alternative Requirements for the Back-End Process Provisions

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Requirements for the Back-End Process Provisions 8 Table 8 to Subpart U of Part 63 Protection of Environment...: Group I Polymers and Resins Pt. 63, Subpt. U, Table 8 Table 8 to Subpart U of Part 63—Summary of... be monitored Requirements Compliance Using Stripping Technology, Demonstrated through Periodic...

  14. Digital terrain tapes: user guide

    USGS Publications Warehouse

    ,

    1980-01-01

    DMATC's digital terrain tapes are a by-product of the agency's efforts to streamline the production of raised-relief maps. In the early 1960's DMATC developed the Digital Graphics Recorder (DGR) system that introduced new digitizing techniques and processing methods into the field of three-dimensional mapping. The DGR system consisted of an automatic digitizing table and a computer system that recorded a grid of terrain elevations from traces of the contour lines on standard topographic maps. A sequence of computer accuracy checks was performed and then the elevations of grid points not intersected by contour lines were interpolated. The DGR system produced computer magnetic tapes which controlled the carving of plaster forms used to mold raised-relief maps. It was realized almost immediately that this relatively simple tool for carving plaster molds had enormous potential for storing, manipulating, and selectively displaying (either graphically or numerically) a vast number of terrain elevations. As the demand for the digital terrain tapes increased, DMATC began developing increasingly advanced digitizing systems and now operates the Digital Topographic Data Collection System (DTDCS). With DTDCS, two types of data elevations as contour lines and points, and stream and ridge lines are sorted, matched, and resorted to obtain a grid of elevation values for every 0.01 inch on each map (approximately 200 feet on the ground). Undefined points on the grid are found by either linear or or planar interpolation.

  15. Arch-Taping Techniques for Altering Navicular Height and Plantar Pressures During Activity

    PubMed Central

    Newell, Tim; Simon, Janet; Docherty, Carrie L.

    2015-01-01

    Context Arch tapings have been used to support the arch by increasing navicular height. Few researchers have studied navicular height and plantar pressures after physical activity. Objective To determine if taping techniques effectively support the arch during exercise. Design Crossover study. Setting Athletic training research laboratory. Patients or Other Participants Twenty-five individuals (13 men, 12 women; age = 20.0 ± 1.0 years, height = 172.3 ± 6.6 cm, mass = 70.1 ± 10.2 kg) with a navicular drop of more than 8 mm (12.9 ± 3.3 mm) volunteered. Intervention(s) All individuals participated in 3 days of testing, with 1 day for each tape condition: no tape, low dye, and navicular sling. On each testing day, navicular height and plantar pressures were measured at 5 intervals: baseline; posttape; and after 5, 10, and 15 minutes of running. The order of tape condition was counterbalanced. Main Outcome Measure(s) The dependent variables were navicular height in millimeters and plantar pressures in kilopascals. Plantar pressures were divided into 5 regions: medial forefoot, lateral forefoot, lateral midfoot, lateral rearfoot, and medial rearfoot. Separate repeated-measures analyses of variance were conducted for each dependent variable. Results Navicular height was higher immediately after application of the navicular-sling condition (P = .004) but was reduced after 5 minutes of treadmill running (P = .12). We observed no differences from baseline to posttape for navicular height for the low-dye (P = .30) and no-tape conditions (P = .25). Both the low-dye and navicular-sling conditions increased plantar pressures in the lateral midfoot region compared with the no-tape condition. The low-dye condition created decreased pressure in the medial and lateral forefoot regions compared with the no-tape condition. All changes were identified immediately after application and were maintained during running. No changes were noted in plantar pressures for the no-tape

  16. High-throughput DNA extraction of forensic adhesive tapes.

    PubMed

    Forsberg, Christina; Jansson, Linda; Ansell, Ricky; Hedman, Johannes

    2016-09-01

    Tape-lifting has since its introduction in the early 2000's become a well-established sampling method in forensic DNA analysis. Sampling is quick and straightforward while the following DNA extraction is more challenging due to the "stickiness", rigidity and size of the tape. We have developed, validated and implemented a simple and efficient direct lysis DNA extraction protocol for adhesive tapes that requires limited manual labour. The method uses Chelex beads and is applied with SceneSafe FAST tape. This direct lysis protocol provided higher mean DNA yields than PrepFiler Express BTA on Automate Express, although the differences were not significant when using clothes worn in a controlled fashion as reference material (p=0.13 and p=0.34 for T-shirts and button-down shirts, respectively). Through in-house validation we show that the method is fit-for-purpose for application in casework, as it provides high DNA yields and amplifiability, as well as good reproducibility and DNA extract stability. After implementation in casework, the proportion of extracts with DNA concentrations above 0.01ng/μL increased from 71% to 76%. Apart from providing higher DNA yields compared with the previous method, the introduction of the developed direct lysis protocol also reduced the amount of manual labour by half and doubled the potential throughput for tapes at the laboratory. Generally, simplified manual protocols can serve as a cost-effective alternative to sophisticated automation solutions when the aim is to enable high-throughput DNA extraction of complex crime scene samples. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  17. Tape-recorded Lectures With Slide Synchronization

    ERIC Educational Resources Information Center

    Goodhue, D.

    1969-01-01

    Describes "Taped Explanation Slide Synchronization" programs used for individual study or group showing in college zoology. Discusses preparation of programs, class organization, equipment, and costs. (EB)

  18. 62. SOUTH CORNER OF BUILDING 372 (HAZARDOUS STORAGE) IN BASE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    62. SOUTH CORNER OF BUILDING 372 (HAZARDOUS STORAGE) IN BASE SPARES AREA. - Loring Air Force Base, Weapons Storage Area, Northeastern corner of base at northern end of Maine Road, Limestone, Aroostook County, ME

  19. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 3 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 6 and 7. The activities from other flight days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). Flight day 6 features a very complicated EVA (extravehicular activity) to service the HST (Hubble Space Telescope). Astronauts Grunsfeld and Linnehan replace the HST's power control unit, disconnecting and reconnecting 36 tiny connectors. The procedure includes the HST's first ever power down. The cleanup of spilled water from the coollant system in Grunsfeld's suit is shown. The pistol grip tool, and two other space tools are also shown. On flight day 7, Newman and Massimino conduct an EVA. They replace the HST's FOC (Faint Object Camera) with the ACS (Advanced Camera for Surveys). The video ends with crew members playing in the shuttle's cabin with a model of the HST.

  20. The ISEE-3 ULEWAT: Flux tape description and heavy ion fluxes 1978-1984. [plasma diagnostics

    NASA Technical Reports Server (NTRS)

    Mason, G. M.; Klecker, B.

    1985-01-01

    The ISEE ULEWAT FLUX tapes contain ULEWAT and ISEE pool tape data summarized over relatively long time intervals (1hr) in order to compact the data set into an easily usable size. (Roughly 3 years of data fit onto one 1600 BPI 9-track magnetic tape). In making the tapes, corrections were made to the ULEWAT basic data tapes in order to, remove rate spikes and account for changes in instrument response so that to a large extent instrument fluxes can be calculated easily from the FLUX tapes without further consideration of instrument performance.

  1. Mariner 9 data storage subsystem flight performance summary

    NASA Technical Reports Server (NTRS)

    Thomas, N. E.; Larman, B. T.

    1973-01-01

    The performance is summarized of the Mariner 9 Data Storage Subsystem (DSS) throughout the primary and extended missions. Information presented is limited to reporting of anomalies which occurred during the playback sequences. Tables and figures describe the anomalies (dropouts, missing and added bits, in the imaging data) as a function of time (accumulated tape passes). The data results indicate that the performance of the DSS was satisfactory and within specification throughout the mission. The data presented is taken from the Spacecraft Team Incident/Surprise Anomaly Log recorded during the mission. Pertinent statistics concerning the tape transport performance are given. Also presented is a brief description of DSS operation, particularly that related to the recorded anomalies. This covers the video data encoding and how it is interpreted/decoded by ground data processing and the functional operation of the DSS in abnormal conditions such as loss of lock to the playback signal.

  2. Fabrication of high edge-definition steel-tape gratings for optical encoders.

    PubMed

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO 2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  3. Fabrication of high edge-definition steel-tape gratings for optical encoders

    NASA Astrophysics Data System (ADS)

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  4. A 16-channel cassette tape recorder system for clinical EEGs.

    PubMed

    Barlow, J S

    1975-02-01

    A 16-channel EEG tape recorder system having a frequency response of DC-100 Hz for each channel is described. The system utilized standard commercially available highfidelity audio tape decks in conjunction with specially designed circuits for time-division multiplexing a balanced amplitude modulation

  5. Ultrasound assessment of tension-free vaginal tape (TVT).

    PubMed

    Flock, F; Kohorst, F; Kreienberg, R; Reich, A

    2011-01-01

    To date, no standardization for the visualization of tension-free vaginal tape (TVT) has been established in clinical practice. The aim of this prospective observational study was to evaluate the shape and position of the tape using ultrasound and to compare this data with clinical postoperative results. In a three-year period, 296 patients with clinically and urodynamically proven stress urinary incontinence (SUI) were treated with TVT and received follow-up in our department. An additional 12 patients, who were initially treated in other hospitals and had postoperative problems, were included in this study. Depending on the outcome after 3 months, the patients were divided into groups with and without specific disorders. The TVT was evaluated by introital ultrasound. The position of the tape was established by its location in relation to the urethral length and the distance to the hypoechoic center of the urethra (HCU). A suitable TVT position was determined in patients without any postoperative disorders. The mean value for the TVT position at rest in relation to the urethral length was 61 %. The distance to the HCU was 4.6 ± 1.5 mm. In patients with persistent SUI, the tape was more often located under the inner (3 % vs. 0 %) or outer quarter (29 % vs. 13 %, p = 0.004). In patients with residual volume, the distance to the urethra was significantly lower (2.7 vs. 4.6, p < 0.001). TVT may be regularly investigated using ultrasound. In combination with the clinical outcome, it represents an important method of evaluating the tape and assists in the planning of a future therapeutic course of action in cases of postoperative problems. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Burnout Test of First- and Second-Generation HTS Tapes in Liquid-Nitrogen Bath Cooling

    NASA Astrophysics Data System (ADS)

    Young, M. A.; Demko, J. A.; Duckworth, R. C.; Lue, J. W.; Gouge, M. J.; Pace, M. O.

    2004-06-01

    A series of BSCCO-2223 and YBCO tapes were subjected to burnout tests in a liquid-nitrogen bath to observe operational stability limits when different layers of dielectric tape are added to the sample surface. In this study, the BSCCO tapes were composed of a silver/alloy sheath with nickel/copper plating, while the YBCO tapes had a 50-μm layer of copper attached to the silver surface. After attaching the tapes to a thermally insulated G-10 holder, the stability of the tapes was found by applying current greater than the critical current and holding it constant for up to 1 min. If the sample voltage increased rapidly during this period, the tape was considered unstable at this current. This was repeated at different layers of Cryoflex™, and the results were compared to a numerical simulation of the energy balance equation. This simulation was also utilized to investigate the effect of the layers on the stability limit and estimate the thermal conductivity of the Cryoflex™.

  7. PNNL Development and Analysis of Material-Based Hydrogen Storage Systems for the Hydrogen Storage Engineering Center of Excellence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brooks, Kriston P.; Alvine, Kyle J.; Johnson, Kenneth I.

    The Hydrogen Storage Engineering Center of Excellence is a team of universities, industrial corporations, and federal laboratories with the mandate to develop lower-pressure, materials-based, hydrogen storage systems for hydrogen fuel cell light-duty vehicles. Although not engaged in the development of new hydrogen storage materials themselves, it is an engineering center that addresses engineering challenges associated with the currently available hydrogen storage materials. Three material-based approaches to hydrogen storage are being researched: 1) chemical hydrogen storage materials 2) cryo-adsorbents, and 3) metal hydrides. As a member of this Center, Pacific Northwest National Laboratory (PNNL) has been involved in the design andmore » evaluation of systems developed with each of these three hydrogen storage materials. This report is a compilation of the work performed by PNNL for this Center.« less

  8. Tape casting and partial melting of Bi-2212 thick films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buhl, D.; Lang, T.; Heeb, B.

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density ofmore » 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).« less

  9. Flux pinning in nanoparticle doped MgB 2/Cu tapes

    NASA Astrophysics Data System (ADS)

    Babić, E.; Kušević, I.; Husnjak, O.; Soltanian, S.; Wang, X. L.; Dou, S. X.

    2007-09-01

    The irreversibility fields Birr and critical current densities Jc of undoped and Si and SiC nanoparticle doped (5, 10 and 20 wt%) MgB2 tapes were measured in the temperature (T) range 2-38 K and in magnetic fields B ⩽ 16 T. Whereas Birr of undoped tapes varies smoothly with T, those of doped tapes show a change in slope around a crossover field Bcr which increases with nanoparticle content and also depends on their type. This indicates matching effect in vortex pinning, probably associated with Mg2Si nanoprecipitates formed during heat treatment. Indeed, Birr of doped tapes was enhanced in respect to that of undoped one with the highest enhancement for Birr ≈ Bcr, but the enhancement remained high ≈1.4 even for Birr ≫ Bcr (low temperatures). The variations of Jc and the pinning force density Fp = JcB with B and T support the above findings.

  10. Tape casting and partial melting of Bi-2212 thick films

    NASA Technical Reports Server (NTRS)

    Buhl, D.; Lang, TH.; Heeb, B.; Gauckler, L. J.

    1995-01-01

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 microns. The orientation of the (a,b)-plane of the grains was parallel to the substrate with a misalignment of less than 6 deg. At 77 K/0T a critical current density of 15, 000 A/sq cm was reached in films of the dimension 1 cm x 2 cm x 20 microns (1 micron V/cm criterion, resistively measured). At 4 K/0T the highest value was 350,000 A/sq cm (1 nV/cm criterion, magnetically measured).

  11. Turning Archival Tapes into an Online “Cardless” Catalog

    PubMed Central

    Zuckerman, Alan E.; Ewens, Wilma A.; Cannard, Bonnie G.; Broering, Naomi C.

    1982-01-01

    Georgetown University has created an online card catalog based on machine readable cataloging records (MARC) loaded from archival tapes or online via the OCLC network. The system is programmed in MUMPS and uses the medical subject headings (MeSH) authority file created by the National Library of Medicine. The online catalog may be searched directly by library users and has eliminated the need for manual filing of catalog cards.

  12. Generation and physical characteristics of the Landsat 1 and 2 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1975-01-01

    The generation and format is discussed of the Landsat 1 and 2 system corrected multispectral scanner computer compatible tapes. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes at the NASA Data Processing Facility. Geometric and radiometric corrections, tape formats, and the physical characteristics of the tape are also described.

  13. Influence of TVT properties on outcomes of midurethral sling procedures: high-stiffness versus low-stiffness tape.

    PubMed

    Prien-Larsen, Jens Christian; Prien-Larsen, Thomas; Cieslak, Lars; Dessau, Ram B

    2016-07-01

    Although there is clear consensus on the use of monofilament polypropylene tapes for treating stress urinary incontinence (SUI), tapes differ in weight, stiffness, and elasticity. In this study, we compared outcomes of two tape types: high-stiffness Intramesh SOFT L.I.F.T versus low-stiffness Intramesh L.I.F.T. tape. Our null hypothesis was that in terms of performance, SOFT tape equaled L.I.F.T. tape. Six hundred and sixty women underwent prospective transvaginal tape (TVT) surgery for SUI: 210 had the SOFT tape placed and 450 the L.I.F.T. tape. Follow-ups were scheduled at 3 and 12 months. Objective cure at 3-months' follow-up was 87 % in the SOFT group vs 94 % in the L.I.F.T. group (p = 0.003) and at 12 months 86 vs 96 % (p = 0.0004), respectively. Subjective outcomes were equal. For SOFT tape, the objective failure rate at 3 months was especially pronounced in women older than 70 years: 31 vs 10 % (p = 0.008), and subjective failure was 24 vs 7 % (p = 0.01). At 12 months, objective failure for the SOFT tape was significantly higher in both age groups compared with L.I.F.T. [odds ratio (OR) 2.17]. Multivariate analysis showed that body mass index (BMI) ≥30 (OR 2.41), mixed incontinence (MUI) (OR 2.24), use of SOFT tape (OR 2.17), and age ≥ 70 years are significant independent risk factors for surgical failure. Outcomes with SOFT tape are significantly inferior than with L.I.F.T. tape, especially among elderly women. Therefore, the two variants of monofilament polypropylene tape are not interchangeable.

  14. High data volume and transfer rate techniques used at NASA's image processing facility

    NASA Technical Reports Server (NTRS)

    Heffner, P.; Connell, E.; Mccaleb, F.

    1978-01-01

    Data storage and transfer operations at a new image processing facility are described. The equipment includes high density digital magnetic tape drives and specially designed controllers to provide an interface between the tape drives and computerized image processing systems. The controller performs the functions necessary to convert the continuous serial data stream from the tape drive to a word-parallel blocked data stream which then goes to the computer-based system. With regard to the tape packing density, 1.8 times 10 to the tenth data bits are stored on a reel of one-inch tape. System components and their operation are surveyed, and studies on advanced storage techniques are summarized.

  15. Deployment Analysis of a Simple Tape-Spring Hinge Using Probabilistic Methods

    NASA Technical Reports Server (NTRS)

    Lyle, Karen H.; Horta, Lucas G.

    2012-01-01

    Acceptance of new deployable structures architectures and concepts requires validated design methods to minimize the expense involved with technology validation flight testing. Deployable concepts for large lightweight spacecraft include booms, antennae, and masts. This paper explores the implementation of probabilistic methods in the design process for the deployment of a strain-energy mechanism, specifically a simple tape-spring hinge. Strain-energy mechanisms are attractive for deployment in very lightweight systems because they do not require the added mass and complexity associated with motors and controllers. However, designers are hesitant to include free deployment, strain-energy mechanisms because of the potential for uncontrolled behavior. In the example presented here, the tapespring cross-sectional dimensions have been varied and a target displacement during deployment has been selected as the design metric. Specifically, the tape-spring should reach the final position in the shortest time with the minimal amount of overshoot and oscillations. Surrogate models have been used to reduce computational expense. Parameter values to achieve the target response have been computed and used to demonstrate the approach. Based on these results, the application of probabilistic methods for design of a tape-spring hinge has shown promise as a means of designing strain-energy components for more complex space concepts.

  16. JPL Ephemeris Tapes E9510, E9511, and E9512

    NASA Technical Reports Server (NTRS)

    Peabody, P. R.; Scott, J. F.; Orozco, E. G.

    1964-01-01

    The first issue of JPL Ephemeris Tapes is described. These tapes carry the positions and velocities of the planets and of the Moon, plus nutations and nutation rates in longitude and obliquity, together with second and fourth modified differences, for the interval December 30, 1949, to January 5, 2000.

  17. Detection of latent fingerprint hidden beneath adhesive tape by optical coherence tomography.

    PubMed

    Zhang, Ning; Wang, Chengming; Sun, Zhenwen; Li, Zhigang; Xie, Lanchi; Yan, Yuwen; Xu, Lei; Guo, Jingjing; Huang, Wei; Li, Zhihui; Xue, Jing; Liu, Huan; Xu, Xiaojing

    2018-06-01

    Adhesive tape is one type of common item which can be encountered in criminal cases involving rape, murder, kidnapping and explosives. It is often the case that a suspect deposits latent fingerprints on the sticky side of adhesive tape material when tying up victims, manufacturing improvised explosive devices or packaging illegal goods. However, the adhesive tapes found at crime scenes are usually stuck together or attached to a certain substrate, and thus the latent fingerprints may be hidden beneath the tapes. Current methods to detect latent fingerprint hidden beneath adhesive tape need to peel it off first and then apply physical or chemical methods to develop the fingerprint, which undergo complicated procedures and would affect the original condition of latent print. Optical coherence tomography (OCT) is a novel applied techniques in forensics which enables obtaining cross-sectional structure with the advantages of non-invasive, in-situ, high resolution and high speed. In this paper, a custom-built spectral-domain OCT (SD-OCT) system with a hand-held probe was employed to detect fingerprints hidden beneath different types of adhesive tapes. Three-dimensional (3D) OCT reconstructions were performed and the en face images were presented to reveal the hidden fingerprints. The results demonstrate that OCT is a promising tool for rapidly detecting and recovering high quality image of latent fingerprint hidden beneath adhesive tape without any changes to the original state and preserve the integrity of the evidence. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Testing of machine wound second generation HTS tape Vacuum Pressure Impregnated coils

    NASA Astrophysics Data System (ADS)

    Swaffield, D.; Lewis, C.; Eugene, J.; Ingles, M.; Peach, D.

    2014-05-01

    Delamination of second generation (2G) High Temperature Superconducting (HTS) tapes has previously been reported when using resin based insulation systems for wound coils. One proposed root cause is the differential thermal contraction between the coil former and the resin encapsulated coil turns resulting in the tape c-axis tensile stress being exceeded. Importantly, delamination results in unacceptable degradation of the superconductor critical current level. To mitigate the delamination risk and prove winding, jointing and Vacuum Pressure Impregnation (VPI) processes in the production of coils for superconducting rotating machines at GE Power Conversion two scaled trial coils have been wound and extensively tested. The coils are wound from 12mm wide 2G HTS tape supplied by AMSC onto stainless steel 'racetrack' coil formers. The coils are wound in two layers which include both in-line and layer-layer joints subject to in-process test. The resin insulation system chosen is VPI and oven cured. Tests included; insulation resistance, repeat quench and recovery of the superconductor, heat runs and measurement of n-value, before and after multiple thermal cycling between ambient and 35 Kelvin. No degradation of coil performance is evidenced.

  19. The Influence of the Tape-Recorder on Attainment in EFL.

    ERIC Educational Resources Information Center

    Al-Ansari, Saif; Wigzell, Roy

    1996-01-01

    Reports a study undertaken in Bahrain secondary schools to assess the contribution of tape recorders to learning outcomes in English as a Second Language (ESL). Findings revealed that students' proficiency correlated significantly with their perception of the frequency and skill with which their teacher use a tape recorder. (20 references)…

  20. 41 CFR 101-26.508-2 - Requisitioning data processing tape not available from Federal Supply Schedule contracts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... contracts. (a) Requisitions for types of EDP tape and instrumentation tape (wide and intermediate band... is located. (b) Requisitions for all types of EDP tape and instrumentation tape (wide and... and $5,000 for instrumentation tape. However, regardless of the amount involved (including...

  1. Age-of-Air, Tape Recorder, and Vertical Transport Schemes

    NASA Technical Reports Server (NTRS)

    Lin, S.-J.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A numerical-analytic investigation of the impacts of vertical transport schemes on the model simulated age-of-air and the so-called 'tape recorder' will be presented using an idealized 1-D column transport model as well as a more realistic 3-D dynamical model. By comparing to the 'exact' solutions of 'age-of-air' and the 'tape recorder' obtainable in the 1-D setting, useful insight is gained on the impacts of numerical diffusion and dispersion of numerical schemes used in global models. Advantages and disadvantages of Eulerian, semi-Lagrangian, and Lagrangian transport schemes will be discussed. Vertical resolution requirement for numerical schemes as well as observing systems for capturing the fine details of the 'tape recorder' or any upward propagating wave-like structures can potentially be derived from the 1-D analytic model.

  2. The Ergogenic Effect of Elastic Therapeutic Tape on Stride and Step Length in Fatigued Runners

    PubMed Central

    Ward, John; Sorrels, Kenneth; Coats, Jesse; Pourmoghaddam, Amir; Moskop, JoAnn; Ueckert, Kate; Glass, Amanda

    2014-01-01

    Objective The purpose of this study was to determine if elastic therapeutic tape placed on anterior lower limbs would affect stride and step length in fatigued runners’ gait. Methods Forty-two healthy participants were equally divided into a kinesiology tape group (Rocktape) and a no-tape control group. Participants in both groups underwent a baseline running gait test at 6 mph without tape. After this, participants engaged in an exhaustive lower body fatigue protocol until they reached maximal volitional exhaustion. Participants were then randomized to 1 of 2 interventions: (1) Experimental group, which had kinesiology tape placed under tension on the anterior aspect of their lower limbs bilaterally from the upper thigh to just below the patella, or (2) Control group, which did not receive taping. All participants then engaged in a similar 6-mph running gait postanalysis. Participant’s gait was analyzed for 90 seconds during each test iteration. Researchers used a 2-way repeated-measures analysis of variance considering fatigue (prefatigue, postfatigue) and group (tape, no-tape) as subject factors. Results After the fatigue protocol, the no-tape group demonstrated a significant decrease in step length of 14.2 mm (P = .041) and stride length of 29.4 mm (P = .043). The kinesiology tape group did not demonstrate a significant decline in these gait parameters. Conclusions In this preliminary study, placing elastic therapeutic tape over the anterior lower limbs demonstrated short-term preservation of runner step length and stride length in a fatigued state. PMID:25435835

  3. Evaluation of a new silicone adhesive tape among clinicians caring for patients with fragile or at-risk skin.

    PubMed

    Manriquez, Sonia; Loperfido, Bonnie; Smith, Graham

    2014-04-01

    To evaluate performance of a new silicone tape among clinicians caring for patients with fragile skin. An international, multisite, 2-week-use evaluation. Caregivers (n = 217) from acute care hospitals in the United States, United Kingdom, and France who regularly use tapes on patients with fragile skin. The silicone tape was substituted for current-use gentle tapes for a 2-week trial period. Preuse and postuse questionnaires were collected. The main outcome measure was tape preference. Secondary outcomes included (1) satisfaction with current-use tapes, (2) willingness to replace current-use tapes with silicone tape, (3) performance comparisons between tapes, (4) clinician-reported problems with the silicone tape, and (5) case study information. The sample group consisted of nurses (98.1%), assistants (1.4%), and physicians (0.5%). Hospital units (n = 100) included oncology (31%), medical-surgical (14%), dialysis (12%), infusion/intravenous therapy (16%), critical care (10%), wound care (10%), and other units (7%). Overall preference was 92.0% for the silicone tape, 7.5% for current-use tapes, and 0.5% no preference. Dissatisfaction was 61.2% for current-use tapes, and most clinicians (90.2%) would change to the silicone tape. Evaluators favored (≥71.5%) the silicone tape on 10 performance attributes and on overall performance (91.6%). Most evaluators (75.1%) did not experience problems with the silicone tape, and those who did found problems related to adhesion (77.8%), gentleness (16.0%), and residue (6.2%). These results indicate that the silicone tape fills a performance-expectation gap of current acrylic tapes among users of tapes on patients with fragile or at-risk skin.

  4. Tape functionality: position, change in shape, and outcome after TVT procedure--mid-term results.

    PubMed

    Kociszewski, Jacek; Rautenberg, Oliver; Kolben, Sebastian; Eberhard, Jakob; Hilgers, Reinhard; Viereck, Volker

    2010-07-01

    This study evaluates the relevance of the tape position and change in shape (tape functionality) under in vivo conditions for mid-term outcome. Changes in the sonographic tension-free vaginal tape (TVT) position relative to the percentage urethral length and the tape-urethra distance were determined after 6 and 48 months in 41 women with stress urinary incontinence. At 48 months, 76% (31/41) of women were cured, 17% (7/41) were improved, and 7% (3/41) were failures. Disturbed bladder voiding was present in 12% (5/41), de novo urge incontinence in 7% (3/41). The median TVT position was at 63% of urethral length. Median tape-urethra distance was 2.7 mm, ranging from 2.9 mm in continent patients without complications to 1.1 mm in those with obstructive complications. Patients with postoperative urine loss had a median distance of 3.9 mm. The tape was stretched at rest and C-shaped during straining in 15 of 41 women (37%) at 48 months (all continent). Patients with this tape functionality at 6 months were also cured at 48 months in 86% of cases (19/22), and only 14% (3/22) showed recurrent incontinence. Mid-term data suggest an optimal outcome if the tape is positioned at least 2 mm from the urethra at the junction of the middle and distal thirds. Patients with optimal tape functionality at 6 months are likely to show mid-term therapeutic success.

  5. AC losses in horizontally parallel HTS tapes for possible wireless power transfer applications

    NASA Astrophysics Data System (ADS)

    Shen, Boyang; Geng, Jianzhao; Zhang, Xiuchang; Fu, Lin; Li, Chao; Zhang, Heng; Dong, Qihuan; Ma, Jun; Gawith, James; Coombs, T. A.

    2017-12-01

    This paper presents the concept of using horizontally parallel HTS tapes with AC loss study, and the investigation on possible wireless power transfer (WPT) applications. An example of three parallel HTS tapes was proposed, whose AC loss study was carried out both from experiment using electrical method; and simulation using 2D H-formulation on the FEM platform of COMSOL Multiphysics. The electromagnetic induction around the three parallel tapes was monitored using COMSOL simulation. The electromagnetic induction and AC losses generated by a conventional three turn coil was simulated as well, and then compared to the case of three parallel tapes with the same AC transport current. The analysis demonstrates that HTS parallel tapes could be potentially used into wireless power transfer systems, which could have lower total AC losses than conventional HTS coils.

  6. Towards a 1000 tracks digital tape recorder

    NASA Technical Reports Server (NTRS)

    Coutellier, J. M.; Castera, J. P.; Colineau, J.; Lehureau, J. C.; Maurice, F.; Hanna, C.

    1993-01-01

    As the demand for high data rate (up to 1 Gb/s), high density (down to 1 sq micron/bit) tape recorder increases, the main investigation trend is an improvement of the well known helical scan concept. The drawbacks of this technology are also well known; sophisticated mechanics, head to tape contact, and wear problems. In our fixed head approach, the recorder mechanics is made much more simple, but the complexity is turned towards the integrated magnetic components, which have to record and reproduce hundreds of tracks in parallel. Our multiplexed write inductive head and magneto-optical readout head will be described, and the global system performances evaluated.

  7. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    PubMed Central

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-01

    Background It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). Material/Methods Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. Results Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. Conclusions Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow. PMID:29332101

  8. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    PubMed

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-14

    BACKGROUND It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). MATERIAL AND METHODS Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. RESULTS Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. CONCLUSIONS Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow.

  9. Scan converting video tape recorder

    NASA Technical Reports Server (NTRS)

    Holt, N. I. (Inventor)

    1971-01-01

    A video tape recorder is disclosed of sufficient bandwidth to record monochrome television signals or standard NTSC field sequential color at current European and American standards. The system includes scan conversion means for instantaneous playback at scanning standards different from those at which the recording is being made.

  10. Could Blobs Fuel Storage-Based Convergence between HPC and Big Data?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matri, Pierre; Alforov, Yevhen; Brandon, Alvaro

    The increasingly growing data sets processed on HPC platforms raise major challenges for the underlying storage layer. A promising alternative to POSIX-IO- compliant file systems are simpler blobs (binary large objects), or object storage systems. Such systems offer lower overhead and better performance at the cost of largely unused features such as file hierarchies or permissions. Similarly, blobs are increasingly considered for replacing distributed file systems for big data analytics or as a base for storage abstractions such as key-value stores or time-series databases. This growing interest in such object storage on HPC and big data platforms raises the question:more » Are blobs the right level of abstraction to enable storage-based convergence between HPC and Big Data? In this paper we study the impact of blob-based storage for real-world applications on HPC and cloud environments. The results show that blobbased storage convergence is possible, leading to a significant performance improvement on both platforms« less

  11. Petabyte Class Storage at Jefferson Lab (CEBAF)

    NASA Technical Reports Server (NTRS)

    Chambers, Rita; Davis, Mark

    1996-01-01

    By 1997, the Thomas Jefferson National Accelerator Facility will collect over one Terabyte of raw information per day of Accelerator operation from three concurrently operating Experimental Halls. When post-processing is included, roughly 250 TB of raw and formatted experimental data will be generated each year. By the year 2000, a total of one Petabyte will be stored on-line. Critical to the experimental program at Jefferson Lab (JLab) is the networking and computational capability to collect, store, retrieve, and reconstruct data on this scale. The design criteria include support of a raw data stream of 10-12 MB/second from Experimental Hall B, which will operate the CEBAF (Continuous Electron Beam Accelerator Facility) Large Acceptance Spectrometer (CLAS). Keeping up with this data stream implies design strategies that provide storage guarantees during accelerator operation, minimize the number of times data is buffered allow seamless access to specific data sets for the researcher, synchronize data retrievals with the scheduling of postprocessing calculations on the data reconstruction CPU farms, as well as support the site capability to perform data reconstruction and reduction at the same overall rate at which new data is being collected. The current implementation employs state-of-the-art StorageTek Redwood tape drives and robotics library integrated with the Open Storage Manager (OSM) Hierarchical Storage Management software (Computer Associates, International), the use of Fibre Channel RAID disks dual-ported between Sun Microsystems SMP servers, and a network-based interface to a 10,000 SPECint92 data processing CPU farm. Issues of efficiency, scalability, and manageability will become critical to meet the year 2000 requirements for a Petabyte of near-line storage interfaced to over 30,000 SPECint92 of data processing power.

  12. Blood loss in the space of Retzius and pelvis with tension-free vaginal tape and trans-obturator tape procedures.

    PubMed

    Huffaker, R Keith; Copas, Pleas

    2006-11-01

    The purpose of this study was to evaluate the space of Retzius and pelvis for hematoma formation and blood loss following placement of tension-free vaginal tapes (TVT) and transobturator tapes (TOT). 25 women were examined with ultrasonography on post-operative days one, two, three, four or five. One patient underwent TVT while the other 24 underwent TOT. Additional procedures were performed on most patients. No hematomas or collections of free fluid were identified post-operatively. TVT and TOT procedures are relatively safe procedures. We encountered no vascular complications in this small series of patients. Review of literature has yielded reports of infrequent complications.

  13. Water-vapor effects on friction of magnetic tape in contact with nickel-zinc ferrite

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.

    1984-01-01

    The effects of humidity of moist nitrogen on the friction and deformation behavior of magnetic tape in contact with a nickel-zinc ferrite spherical pin were studied. The results indicate that the coefficient of friction is markedly dependent on the ambient relative humidity. Although the coefficient of friction remains low below 40-percent relative humidity, it increases rapidly with increasing relative humidity above 40 percent. The general ambient environment of the tape does not have any effect on the friction behavior if the area where the tape is in sliding contact with the ferrite pin is flooded with controlled nitrogen. The response time for the friction of the tape to humidity changes is about 10 sec. The effect of friction as a function of relative humidity on dehumidifying is very similar to that on humidifying. A surface softening of the tape due to water vapor increases the friction of the tape.

  14. Generation and physical characteristics of the LANDSAT-1, -2 and -3 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1977-01-01

    The generation and format of the LANDSAT 1, 2, and 3 system corrected multispectral scanner computer compatible tapes are discussed. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes. Also included in the discussion are geometric and radiometric corrections, tape formats, and the physical characteristics of the tape.

  15. The Goddard helical tape recorder

    NASA Technical Reports Server (NTRS)

    Martin, F. T.; Mccarthy, D. K.

    1972-01-01

    A spacecraft recorder was developed with the objective of functioning continuously for 5 years. The resulting design employed a metallic tape wound in a 200-turn helix. A direct drive, brushless dc torquer and servo speed control drove the recorder at 3 rpm for recording and 54 rpm for playback.

  16. 36 CFR 1236.28 - What additional requirements apply to the selection and maintenance of electronic records storage...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... storage libraries and test or evaluation areas that contain permanent or unscheduled records must be smoke... the National Institute of Standards and Technology (NIST) Special Publication 500-252, Care and... to discover and correct the causes of data loss. In magnetic computer tape libraries with 1800 or...

  17. Vacuum-free laminated top electrode with conductive tapes for scalable manufacturing of efficient perovskite solar cells

    DOE PAGES

    Shao, Yuchuan; Wang, Qi; Dong, Qingfeng; ...

    2015-06-25

    The efficiency of organometal trihalide perovskites (OTP) solar cells have reached that parity of single crystal silicon, and its nature abundant raw material and solution-process capability promise a bright future for commercialization. However, the vacuum based techniques for metal electrode deposition and additional encapsulation layer increase the cost of the perovskite solar cells dramatically and impede their commercialization process. Here, we report a vacuum-free low temperature lamination technique to fabricate the top electrode by commercial conductive tapes (C-tape). The simple fabrication method yields good quality contact and high efficiency device of 12.7%. The C-tapes also encapsulated the devices effectively, resultingmore » in greatly improved device stability. As a result, the combination of lamination of electrodes and encapsulation layers into a single step significantly reduce the cost of device fabrication.« less

  18. EFFECT OF ATHLETIC TAPING AND KINESIOTAPING® ON MEASUREMENTS OF FUNCTIONAL PERFORMANCE IN BASKETBALL PLAYERS WITH CHRONIC INVERSION ANKLE SPRAINS

    PubMed Central

    Karatas, Nihan; Baltaci, Gul

    2012-01-01

    Background: Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. Purpose: To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Study Design: Crossover Study Design Methods: Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. Results: There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased

  19. Goddard Space Flight Center specification for Helical-Scan 8-millimeter (mm) magnetic digital data tape cartridge

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1992-01-01

    The same kind of standard and controls are established that are currently in use for the procurement of new analog, digital, and IBM/IBM compatible 3480 tape cartridges, and 1 in wide channel video magnetic tapes. The Magnetic Tape Certification Facility (MTCF) maintains a Qualified Products List (QPL) for the procurement of new magnetic media and uses the following specifications for the QPL and Acceptance Tests: (1) NASA TM-79724 is used for the QPL and Acceptance Testing of new analog magnetic tapes; (2) NASA TM-80599 is used for the QPL and Acceptance Testing of new digital magnetic tapes; (3) NASA TM-100702 is used for the QPL and Acceptance Testing of new IBM/IBM compatible 3840 magnetic tape cartridges; and (4) NASA TM-100712 is used for the QPL and Acceptance Testing of new 1 in wide channel video magnetic tapes. This document will be used for the QPL and Acceptance Testing of new Helical Scan 8 mm digital data tape cartridges.

  20. Graphene and graphene-based materials for energy storage applications.

    PubMed

    Zhu, Jixin; Yang, Dan; Yin, Zongyou; Yan, Qingyu; Zhang, Hua

    2014-09-10

    With the increased demand in energy resources, great efforts have been devoted to developing advanced energy storage and conversion systems. Graphene and graphene-based materials have attracted great attention owing to their unique properties of high mechanical flexibility, large surface area, chemical stability, superior electric and thermal conductivities that render them great choices as alternative electrode materials for electrochemical energy storage systems. This Review summarizes the recent progress in graphene and graphene-based materials for four energy storage systems, i.e., lithium-ion batteries, supercapacitors, lithium-sulfur batteries and lithium-air batteries. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Immediate Effects of Kinesiology Taping of Quadriceps on Motor Performance after Muscle Fatigued Induction.

    PubMed

    Ahn, Ick Keun; Kim, You Lim; Bae, Young-Hyeon; Lee, Suk Min

    2015-01-01

    Objectives. The purpose of this cross-sectional single-blind study was to investigate the immediate effects of Kinesiology taping of quadriceps on motor performance after muscle fatigued induction. Design. Randomized controlled cross-sectional design. Subjects. Forty-five subjects participated in this study. Participants were divided into three groups: Kinesiology taping group, placebo taping group, and nontaping group. Methods. Subjects performed short-term exercise for muscle fatigued induction, followed by the application of each intervention. Peak torque test, one-leg single hop test, active joint position sense test, and one-leg static balance test were carried out before and after the intervention. Results. Peak torque and single-leg hopping distance were significantly increased when Kinesiology taping was applied (p < 0.05). But there were no significant effects on active joint position sense and single-leg static balance. Conclusions. We proved that Kinesiology taping is effective in restoring muscle power reduced after muscle fatigued induction. Therefore, we suggest that Kinesiology taping is beneficial for fatigued muscles.

  2. Effects of functional taping compared with sham taping and minimal intervention on pain intensity and static postural control for patients with non-specific chronic low back pain: a randomised clinical trial protocol.

    PubMed

    Jassi, F J; Del Antônio, T; Moraes, R; George, S Z; Chaves, T C

    2017-06-01

    To investigate the immediate and 1-month effects of functional taping to lumbar spine for pain intensity and postural control in patients with chronic non-specific low back pain. Randomised clinical trial. One hundred and twenty participants aged 18 to 50 years. Participants will be allocated at random to receive one of three interventions: functional star-shape taping for 7 days, sham functional taping for 7 days or minimal intervention, one session. The primary outcomes will be pain intensity and postural control. Four measurements of static posturography will be conducted: pre-intervention, immediately after application of the tape, 7 days post-intervention (after removal of the tape) and 1-month follow-up. The secondary outcomes will be low-back-pain-related disability, global perceived effect of treatment and fear avoidance beliefs. Primary and secondary outcomes will be assessed on three occasions: pre-intervention, 7 days post-intervention and at 1-month follow-up. All statistical analyses will be conducted following intention-to-treat principles, and the treatment effects will be calculated using linear mixed models. The results of this study will determine the effects of functional taping on pain intensity and postural control compared with sham taping and minimal intervention. NCT02546466. Copyright © 2016 Chartered Society of Physiotherapy. All rights reserved.

  3. Effects of low-dye taping on plantar pressure pre and post exercise: an exploratory study.

    PubMed

    Nolan, Damien; Kennedy, Norelee

    2009-04-21

    Low-Dye taping is used for excessive pronation at the subtalar joint of the foot. Previous research has focused on the tape's immediate effect on plantar pressure. Its effectiveness following exercise has not been investigated. Peak plantar pressure distribution provides an indirect representation of subtalar joint kinematics. The objectives of the study were 1) To determine the effects of Low-Dye taping on peak plantar pressure immediately post-application. 2) To determine whether any initial effects are maintained following exercise. 12 asymptomatic subjects participated; each being screened for excessive pronation (navicular drop > 10 mm). Plantar pressure data was recorded, using the F-scan, at four intervals during the testing session: un-taped, baseline-taped, post-exercise session 1, and post-exercise session 2. Each exercise session consisted of a 10-minute walk at a normal pace. The foot was divided into 6 regions during data analysis. Repeated-measures analysis of variance (ANOVA) was used to assess regional pressure variations across the four testing conditions. Reduced lateral forefoot peak plantar pressure was the only significant difference immediately post tape application (p = 0.039). This effect was lost after 10 minutes of exercise (p = 0.036). Each exercise session resulted in significantly higher medial forefoot peak pressure compared to un-taped; (p = 0.015) and (p = 0.014) respectively, and baseline-taped; (p = 0.036) and (p = 0.015) respectively. Medial and lateral rearfoot values had also increased after the second session (p = 0.004), following their non-significant reduction at baseline-taped. A trend towards a medial-to-lateral shift in pressure present in the midfoot immediately following tape application was still present after 20 minutes of exercise. Low-Dye tape's initial effect of reduced lateral forefoot peak plantar pressure was lost after a 10-minute walk. However, the tape continued to have an effect on the medial forefoot after

  4. Risk based inspection for atmospheric storage tank

    NASA Astrophysics Data System (ADS)

    Nugroho, Agus; Haryadi, Gunawan Dwi; Ismail, Rifky; Kim, Seon Jin

    2016-04-01

    Corrosion is an attack that occurs on a metallic material as a result of environment's reaction.Thus, it causes atmospheric storage tank's leakage, material loss, environmental pollution, equipment failure and affects the age of process equipment then finally financial damage. Corrosion risk measurement becomesa vital part of Asset Management at the plant for operating any aging asset.This paper provides six case studies dealing with high speed diesel atmospheric storage tank parts at a power plant. A summary of the basic principles and procedures of corrosion risk analysis and RBI applicable to the Process Industries were discussed prior to the study. Semi quantitative method based onAPI 58I Base-Resource Document was employed. The risk associated with corrosion on the equipment in terms of its likelihood and its consequences were discussed. The corrosion risk analysis outcome used to formulate Risk Based Inspection (RBI) method that should be a part of the atmospheric storage tank operation at the plant. RBI gives more concern to inspection resources which are mostly on `High Risk' and `Medium Risk' criteria and less on `Low Risk' shell. Risk categories of the evaluated equipment were illustrated through case study analysis outcome.

  5. TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region.

    PubMed

    Hubka, Petr; Nanka, Ondrej; Masata, Jaromir; Martan, Alois; Svabik, Kamil

    2016-07-01

    The aim of the study was to describe fixation of the TVT ABBREVO and establish whether the tape penetrates through obturator muscles and membrane (obturator complex) into the adductor region and, if so, how far it penetrates. Eight formalin-embalmed female cadavers were used to simulate TVT ABBREVO surgery (totalling 16 insertions). Following tape insertion, dissection was performed and ends of the tape were identified. In cases of penetration, the length of tape penetrating into the adductor region was measured. Of the 16 cases, the tape ended in the obturator membrane in eight, in the internal obturator muscle in one, and penetrated through the obturator membrane into the external obturator muscle in five, where it remained. In two cases, it penetrated through the obturator internus muscle, obturator membrane and obturator externus muscle into the group of thigh adductors; one penetration was by 3 mm and the second by 10 mm. No contact with the obturator nerve or its branches was noted in any case. No TVT contact with the obturator nerve was noted; tape penetrated into the adductor region in two of the 16 cases.

  6. Thermomechanical Analysis of Shape-Memory Composite Tape Spring

    NASA Astrophysics Data System (ADS)

    Yang, H.; Wang, L. Y.

    2013-06-01

    Intelligent materials and structures have been extensively applied for satellite designs in order to minimize the mass and reduce the cost in the launch of the spacecraft. Elastic memory composites (EMCs) have the ability of high-strain packaging and shape-memory effect, but increase the parts and total weight due to the additional heating system. Shape-memory sandwich structures Li and Wang (J. Intell. Mater. Syst. Struct. 22(14), 1605-1612, 2011) can overcome such disadvantage by using the metal skin acting as the heating element. However, the high strain in the micro-buckled metal skin decreases the deployment efficiency. This paper aims to present an insight into the folding and deployment behaviors of shape-memory composite (SMC) tape springs. A thermomechanical process was analyzed, including the packaging deformation at an elevated temperature, shape frozen at the low temperature and shape recovery after reheating. The result shows that SMC tape springs can significantly decrease the strain concentration in the metal skin, as well as exhibiting excellent shape frozen and recovery behaviors. Additionally, possible failure modes of SMC tape springs were also analyzed.

  7. Methods for tape fabrication of continuous filament composite parts and articles of manufacture thereof

    DOEpatents

    Weisberg, Andrew H

    2013-10-01

    A method for forming a composite structure according to one embodiment includes forming a first ply; and forming a second ply above the first ply. Forming each ply comprises: applying a bonding material to a tape, the tape comprising a fiber and a matrix, wherein the bonding material has a curing time of less than about 1 second; and adding the tape to a substrate for forming adjacent tape winds having about a constant distance therebetween. Additional systems, methods and articles of manufacture are also presented.

  8. Short-Term Effects of Kinesio Taping and Cross Taping Application in the Treatment of Latent Upper Trapezius Trigger Points: A Prospective, Single-Blind, Randomized, Sham-Controlled Trial

    PubMed Central

    Słupska, Lucyna; Paprocka-Borowicz, Małgorzata; Taradaj, Jakub; Bidzińska, Gabriela; Marczyński, Daniel; Cynarska, Aleksandra; Rosińczuk, Joanna

    2015-01-01

    Kinesio taping (KT) may be a new treatment in patients with myofascial trigger points (MTrPs). A new method available for taping practitioners is cross taping (CT). The main objective was to determine how CT, KT, and medical adhesive tape (sham group) affect the subjective assessment of resting bioelectrical activity and pain of the upper trapezius muscle (UT) in patients with MTrPs. 105 volunteers were recruited to participate. The primary outcome was resting bioelectrical activity of UT muscle as assessed by surface electromyography (sEMG) in each group and pain intensity on a visual analog scale (VAS). Assessments were collected before and after intervention and after the 24-hours follow-up. No significant differences were observed in bioelectrical activity of UT between pre-, post-, and follow-up results. In three groups patients had significantly lower pain VAS score after the intervention (CT—p < 0.001, KT—p < 0.001, and sham—p < 0.01). The Kruskal-Wallis ANOVA showed no significant differences in almost all measurements between groups. The application of all three types of tapes does not influence the resting bioelectrical activity of UT muscle and may not lead to a reduction in muscle tone in the case of MTrPs. PMID:26491458

  9. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTHWEST. THE CABLES FROM THE PDP ROOM GO THROUGH THE CONCRETE WALL, MAKE A RIGHT ANGLE TURN DOWNWARD, AND DESCEND INTO THE PDP CONTROL ROOM AS VERTICAL TAPES - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  10. Hydrogen-based electrochemical energy storage

    DOEpatents

    Simpson, Lin Jay

    2013-08-06

    An energy storage device (100) providing high storage densities via hydrogen storage. The device (100) includes a counter electrode (110), a storage electrode (130), and an ion conducting membrane (120) positioned between the counter electrode (110) and the storage electrode (130). The counter electrode (110) is formed of one or more materials with an affinity for hydrogen and includes an exchange matrix for elements/materials selected from the non-noble materials that have an affinity for hydrogen. The storage electrode (130) is loaded with hydrogen such as atomic or mono-hydrogen that is adsorbed by a hydrogen storage material such that the hydrogen (132, 134) may be stored with low chemical bonding. The hydrogen storage material is typically formed of a lightweight material such as carbon or boron with a network of passage-ways or intercalants for storing and conducting mono-hydrogen, protons, or the like. The hydrogen storage material may store at least ten percent by weight hydrogen (132, 134) at ambient temperature and pressure.

  11. The backend design of an environmental monitoring system upon real-time prediction of groundwater level fluctuation under the hillslope.

    PubMed

    Lin, Hsueh-Chun; Hong, Yao-Ming; Kan, Yao-Chiang

    2012-01-01

    The groundwater level represents a critical factor to evaluate hillside landslides. A monitoring system upon the real-time prediction platform with online analytical functions is important to forecast the groundwater level due to instantaneously monitored data when the heavy precipitation raises the groundwater level under the hillslope and causes instability. This study is to design the backend of an environmental monitoring system with efficient algorithms for machine learning and knowledge bank for the groundwater level fluctuation prediction. A Web-based platform upon the model-view controller-based architecture is established with technology of Web services and engineering data warehouse to support online analytical process and feedback risk assessment parameters for real-time prediction. The proposed system incorporates models of hydrological computation, machine learning, Web services, and online prediction to satisfy varieties of risk assessment requirements and approaches of hazard prevention. The rainfall data monitored from the potential landslide area at Lu-Shan, Nantou and Li-Shan, Taichung, in Taiwan, are applied to examine the system design.

  12. User's guide to the UTIL-ODRC tape processing program. [for the Orbital Data Reduction Center

    NASA Technical Reports Server (NTRS)

    Juba, S. M. (Principal Investigator)

    1981-01-01

    The UTIL-ODRC computer compatible tape processing program, its input/output requirements, and its interface with the EXEC 8 operating system are described. It is a multipurpose orbital data reduction center (ODRC) tape processing program enabling the user to create either exact duplicate tapes and/or tapes in SINDA/HISTRY format. Input data elements for PRAMPT/FLOPLT and/or BATCH PLOT programs, a temperature summary, and a printed summary can also be produced.

  13. Estimation of hysteretic losses for MgB2 tapes under the operating conditions of a generator

    NASA Astrophysics Data System (ADS)

    Vargas-Llanos, Carlos Roberto; Zermeño, Víctor M. R.; Sanz, Santiago; Trillaud, Frederic; Grilli, Francesco

    2016-03-01

    Hysteretic losses in the MgB2 wound superconducting coils of a 550 kW synchronous hybrid scaled generator were estimated as part of the European project SUPRAPOWER led by the Spanish Fundación Tecnalia Research & Innovation. Particular interest was given to the losses caused by the magnetic flux ripples in the rotor coils originating from the conventional stator during nominal operation. To compute these losses, a 2D finite element analysis was conducted and Maxwell’s equations written in the H-formulation were solved considering the nonlinear material properties of the conductor materials. The modeled tapes are made of multiple MgB2 filaments embedded in a Ni matrix and soldered to a high purity copper strip and insulated with Dacron braid. Three geometrical models of single tape cross sections of decreasing complexity were studied: (1) the first model reproduced closely the actual cross section obtained from tape micrographs. (2) The second model was obtained from the computed elasto-plastic deformation of a round Ni wire. (3) The third model was based on a simplified cross section with the superconducting filaments bundled in a single elliptical bulky structure. The last geometry allowed the validation of the modeling technique by comparing numerical losses with results from well-established analytical expressions. Additionally, the following cases of filament transpositions of the multi-filamentary tape were studied: no transposition, partial and full transposition; thereby improving understanding of the relevance of the tape fabrication process on the magnitude of the determination of ac losses. Finally, choosing the right level of geometrical detail, the following operational regimes of the machine and its impact on individual superconducting tape losses in the rotor were studied: bias-dc current, ramping current under ramping background field and magnetic flux ripples under dc background current and field.

  14. Numerical modeling of laser assisted tape winding process

    NASA Astrophysics Data System (ADS)

    Zaami, Amin; Baran, Ismet; Akkerman, Remko

    2017-10-01

    Laser assisted tape winding (LATW) has become more and more popular way of producing new thermoplastic products such as ultra-deep sea water riser, gas tanks, structural parts for aerospace applications. Predicting the temperature in LATW has been a source of great interest since the temperature at nip-point plays a key role for mechanical interface performance. Modeling the LATW process includes several challenges such as the interaction of optics and heat transfer. In the current study, numerical modeling of the optical behavior of laser radiation on circular surfaces is investigated based on a ray tracing and non-specular reflection model. The non-specular reflection is implemented considering the anisotropic reflective behavior of the fiber-reinforced thermoplastic tape using a bidirectional reflectance distribution function (BRDF). The proposed model in the present paper includes a three-dimensional circular geometry, in which the effects of reflection from different ranges of the circular surface as well as effect of process parameters on temperature distribution are studied. The heat transfer model is constructed using a fully implicit method. The effect of process parameters on the nip-point temperature is examined. Furthermore, several laser distributions including Gaussian and linear are examined which has not been considered in literature up to now.

  15. Kinesio taping in musculoskeletal pain and disability that lasts for more than 4 weeks: is it time to peel off the tape and throw it out with the sweat? A systematic review with meta-analysis focused on pain and also methods of tape application.

    PubMed

    Lim, Edwin Choon Wyn; Tay, Mathew Guo Xiang

    2015-12-01

    In recent years, Kinesio tape has been used to support injured muscle and joints, and relieve pain. We compared the pain and disability in individuals with chronic musculoskeletal pain who were treated with Kinesio taping with those using minimal or other treatment approaches. Searches of eight major electronic databases were conducted. Data for pain and disability scores were extracted. Meta-analyses (wherever possible) with either a fixed or random effect(s) model, standardised mean differences (SMDs) and tests of heterogeneity were performed. Seventeen clinical-controlled trials were identified and included in the meta-analyses. When compared to minimal intervention, Kinesio taping provided superior pain relief (pooled SMD=-0.36, 95% CI -0.64 to -0.09, p=0.009) but the pooled disability scores were not significantly different (pooled SMD=-0.41, 95% CI -0.83 to 0.01, p=0.05). No significant differences were found when comparing Kinesio taping to other treatment approaches for pain (pooled SMD=-0.44, 95% CI -1.69 to 0.82, p=0.49) and disability (pooled SMD=0.08, 95% CI -0.27 to 0.43, p=0.65). Kinesio taping is superior to minimal intervention for pain relief. Existing evidence does not establish the superiority of Kinesio taping to other treatment approaches to reduce pain and disability for individuals with chronic musculoskeletal pain. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  17. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  18. Design study for multi-channel tape recorder system, volume 1

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The means of storing multispectral, high resolution sensor data on an Earth observing satellite are studied. It is concluded that this is best done digitally on a multi-track, longitudinal, magnetic tape recorder. The machine proposed will store 8 X 10 to the 10th power bits of data on 1040 m of 51 mm-wide magnetic tape mounted on two co-planar reels.

  19. High rate of vaginal erosions associated with the mentor ObTape.

    PubMed

    Yamada, Brian S; Govier, Fred E; Stefanovic, Ksenija B; Kobashi, Kathleen C

    2006-08-01

    The transobturator tape method is a newer surgical technique for the treatment of stress urinary incontinence. Limited data exist related to complications with this approach or the types of mesh products used. We report our experience with vaginal erosions associated with the Mentor ObTape and American Medical Systems Monarc transobturator slings. Beginning in December 2003 selected female patients with anatomic urinary incontinence were prospectively followed after placement of the Mentor ObTape. Beginning in January 2004 we also began using the American Medical Systems Monarc in similar patients. Patients were admitted overnight after surgery, discharged on oral antibiotics, and seen in the clinic at 6 weeks postoperatively. A total of 67 patients have undergone placement of the Mentor ObTape and 9 of those patients (13.4%) have had vaginal extrusions of the sling. Eight patients reported a history of persistent vaginal discharge. One patient presented initially to an outside facility with a left thigh abscess tracking to the left inguinal incision site. Each patient was taken back to the operating room for mesh removal. A total of 56 patients have undergone placement of the AMS Monarc and none have had any vaginal erosions. Our high rate of vaginal extrusion using the ObTape has led us to discontinue the use of this product in our institution. Continued followup of all of these patients will be of critical importance.

  20. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process.

    PubMed

    Deng, Bo; Shi, Yaoyao; Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-31

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing.

  1. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process

    PubMed Central

    Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-01

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing. PMID:29385048

  2. Effect of athletic taping and kinesiotaping® on measurements of functional performance in basketball players with chronic inversion ankle sprains.

    PubMed

    Bicici, Seda; Karatas, Nihan; Baltaci, Gul

    2012-04-01

    Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Crossover Study Design Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased performance. (Standing heel rise test: Athletic taping

  3. A Rewritable, Random-Access DNA-Based Storage System.

    PubMed

    Yazdi, S M Hossein Tabatabaei; Yuan, Yongbo; Ma, Jian; Zhao, Huimin; Milenkovic, Olgica

    2015-09-18

    We describe the first DNA-based storage architecture that enables random access to data blocks and rewriting of information stored at arbitrary locations within the blocks. The newly developed architecture overcomes drawbacks of existing read-only methods that require decoding the whole file in order to read one data fragment. Our system is based on new constrained coding techniques and accompanying DNA editing methods that ensure data reliability, specificity and sensitivity of access, and at the same time provide exceptionally high data storage capacity. As a proof of concept, we encoded parts of the Wikipedia pages of six universities in the USA, and selected and edited parts of the text written in DNA corresponding to three of these schools. The results suggest that DNA is a versatile media suitable for both ultrahigh density archival and rewritable storage applications.

  4. A Rewritable, Random-Access DNA-Based Storage System

    NASA Astrophysics Data System (ADS)

    Tabatabaei Yazdi, S. M. Hossein; Yuan, Yongbo; Ma, Jian; Zhao, Huimin; Milenkovic, Olgica

    2015-09-01

    We describe the first DNA-based storage architecture that enables random access to data blocks and rewriting of information stored at arbitrary locations within the blocks. The newly developed architecture overcomes drawbacks of existing read-only methods that require decoding the whole file in order to read one data fragment. Our system is based on new constrained coding techniques and accompanying DNA editing methods that ensure data reliability, specificity and sensitivity of access, and at the same time provide exceptionally high data storage capacity. As a proof of concept, we encoded parts of the Wikipedia pages of six universities in the USA, and selected and edited parts of the text written in DNA corresponding to three of these schools. The results suggest that DNA is a versatile media suitable for both ultrahigh density archival and rewritable storage applications.

  5. Niobium-germanium superconducting tapes for high-field magnet applications

    NASA Technical Reports Server (NTRS)

    Braginski, A. I.; Roland, G. W.; Daniel, M. R.; Woolam, J. A.

    1977-01-01

    A process of fabricating superconducting Nb3Ge tapes by chemical vapor deposition (CVD) has been developed and tapes up to 10 meters long fabricated. The typical properties achieved were: critical temperature T sub c = 20 K, upper critical field H sub c2 = 29 tesla at 4.2 K, and J sub c = 3 to 4 x 10 to the 8th power A m(-2) at 4.2 K, 18 tesla. The relative depression of T sub c and H sub c2 compared with the best thin film samples sputtered on sapphire was due to the presence of Nb5Ge3 second-phase particles used as flux pinning centers and to strains induced by thermal mixmatch with Hastelloy B tape substrates. A peculiar field dependence of flux pinning force that was observed in both CVD and sputtered Nb3Ge indicated a premature pin-breaking mechanism or a phase inhomogeneity. Directions of further optimization work were defined.

  6. Conductive sub-layer of twisted-tape-induced swirl-flow heat transfer in vertical circular tubes with various twisted-tape inserts

    NASA Astrophysics Data System (ADS)

    Hata, K.; Fukuda, K.; Masuzaki, S.

    2018-04-01

    Twisted-tape-induced swirl-flow heat transfer due to exponentially increasing heat inputs with various exponential periods ( Q = Q 0 exp(t/τ), τ = 6.04 to 23.07 s) and twisted-tape-induced pressure drop was systematically measured for various mass velocities ( G = 4115 to 13,656 kg/m2 s), inlet liquid temperatures ( T in = 285.88 to 299.09 K), and inlet pressures ( P in = 847.45 to 943.29 kPa) using an experimental water loop flow. Measurements were made over a 59.2-mm effective length and three sections (upper, middle, and lower positions), within which four potential taps were spot-welded onto the outer surface of a 6-mm-inner-diameter, 69.6-mm-heated length, 0.4-mm-thickness platinum circular test tube. Type SUS304 twisted tapes with a width w = 5.6 mm, a thickness δ T = 0.6 mm, a total length l = 372 mm, and twist ratios y = 2.39 and 4.45 were employed in this study. The RANS equations (Reynolds Averaged Navier-Stokes Simulation) with a k-ɛ turbulence model for a circular tube 6 mm in diameter and 636 mm in length were numerically solved for heating of water with a heated section 6 mm in diameter and 70 mm in length using the CFD code, under the same conditions as the experimental ones and considering the temperature dependence of the thermo-physical properties concerned. The theoretical values of surface heat flux q on the circular tubes with twisted tapes with twist ratios y of 2.39 and 4.45 were found to be almost in agreement with the corresponding experimental values of heat flux q, with deviations of less than 30% for the range of temperature difference between the average heater inner surface temperature and the liquid bulk mean temperature ΔT L [ = T s,av - T L , T L = ( T in + T out )/2] considered in this study. The theoretical values of the local surface temperature T s , local average liquid temperature T f,av , and local liquid pressure drop ΔP x were found to be within almost 15% of the corresponding experimental ones. The thickness of the

  7. Processing Satellite Images on Tertiary Storage: A Study of the Impact of Tile Size on Performance

    NASA Technical Reports Server (NTRS)

    Yu, JieBing; DeWitt, David J.

    1996-01-01

    Before raw data from a satellite can be used by an Earth scientist, it must first undergo a number of processing steps including basic processing, cleansing, and geo-registration. Processing actually expands the volume of data collected by a factor of 2 or 3 and the original data is never deleted. Thus processing and storage requirements can exceed 2 terrabytes/day. Once processed data is ready for analysis, a series of algorithms (typically developed by the Earth scientists) is applied to a large number of images in a data set. The focus of this paper is how best to handle such images stored on tape using the following assumptions: (1) all images of interest to a scientist are stored on a single tape, (2) images are accessed and processed in the order that they are stored on tape, and (3) the analysis requires access to only a portion of each image and not the entire image.

  8. THE EFFECTS OF VIDEO-TAPING PROCEDURES IN AN EXPERIMENTAL READING PROGRAM.

    ERIC Educational Resources Information Center

    SCHWARTZ-LITTMANN, CAROLE

    THE EXPERIMENTAL USE OF VIDEO AND TAPE RECORDINGS IN TEACHING THREE NEUROLOGICALLY DISABLED BOYS AGED 8, 9, AND 10 TO READ IS REPORTED. EXPERIENCE CHARTS WERE USED TO PRESENT BOTH UNCONTROLLED AND CONTROLLED VOCABULARY. THREE SPACES VIDEO-TAPED DEMONSTRATIONS WITH THE CHILDREN WERE USED TO DIAGNOSE PROGRESS AND AS MOTIVATIONAL DEVICES. THE…

  9. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 1 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 1 through 3. The activities from other flight days can be seen on 'STS 109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), 'STS 109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139471), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The main activity recorded during flight day 1 is the liftoff of Columbia. Attention is given to suit-up, boarding, and pre-flight procedures. The pre-launch crew meal has no sound. The crew members often wave to the camera before liftoff. The jettisoning of the solid rocket boosters is shown, and the External Tank is seen as it falls to Earth, moving over African dunes in the background. There are liftoff replays, including one from inside the cockpit. The opening of the payload bay doors is seen from the rear of the shuttle's cockpit. The footage from flight day 2 shows the Flight Support System for bearthing the HST (Hubble Space Telescope). Crew preparations for the bearthing are shown. Flight day 3 shows the tracking of and approach to the HST by Columbia, including orbital maneuvers, the capture of the HST, and its lowering onto the Flight Support System. Many views of the HST are shown, including one which reveals an ocean and cloud background as the HST retracts a solar array.

  10. Strongly enhanced current densities in Sr0.6K0.4Fe2As2 + Sn superconducting tapes.

    PubMed

    Lin, He; Yao, Chao; Zhang, Xianping; Zhang, Haitao; Wang, Dongliang; Zhang, Qianjun; Ma, Yanwei; Awaji, Satoshi; Watanabe, Kazuo

    2014-03-25

    Improving transport current has been the primary topic for practical application of superconducting wires and tapes. However, the porous nature of powder-in-tube (PIT) processed iron-based tapes is one of the important reasons for low critical current density (Jc) values. In this work, the superconducting core density of ex-situ Sr0.6K0.4Fe2As2 + Sn tapes, prepared from optimized precursors, was significantly improved by employing a simple hot pressing as an alternative route for final sintering. The resulting samples exhibited optimal critical temperature (Tc), sharp resistive transition, small resistivity and high Vickers hardness (Hv) value. Consequently, the transport Jc reached excellent values of 5.1 × 10(4) A/cm(2) in 10 T and 4.3 × 10(4) A/cm(2) in 14 T at 4.2 K, respectively. Our tapes also exhibited high upper critical field Hc2 and almost field-independent Jc. These results clearly demonstrate that PIT pnictide wire conductors are very promising for high-field magnet applications.

  11. Strongly enhanced current densities in Sr0.6K0.4Fe2As2 + Sn superconducting tapes

    PubMed Central

    Lin, He; Yao, Chao; Zhang, Xianping; Zhang, Haitao; Wang, Dongliang; Zhang, Qianjun; Ma, Yanwei; Awaji, Satoshi; Watanabe, Kazuo

    2014-01-01

    Improving transport current has been the primary topic for practical application of superconducting wires and tapes. However, the porous nature of powder-in-tube (PIT) processed iron-based tapes is one of the important reasons for low critical current density (Jc) values. In this work, the superconducting core density of ex-situ Sr0.6K0.4Fe2As2 + Sn tapes, prepared from optimized precursors, was significantly improved by employing a simple hot pressing as an alternative route for final sintering. The resulting samples exhibited optimal critical temperature (Tc), sharp resistive transition, small resistivity and high Vickers hardness (Hv) value. Consequently, the transport Jc reached excellent values of 5.1 × 104 A/cm2 in 10 T and 4.3 × 104 A/cm2 in 14 T at 4.2 K, respectively. Our tapes also exhibited high upper critical field Hc2 and almost field-independent Jc. These results clearly demonstrate that PIT pnictide wire conductors are very promising for high-field magnet applications. PMID:24663054

  12. Strongly enhanced current densities in Sr0.6K0.4Fe2As2 + Sn superconducting tapes

    NASA Astrophysics Data System (ADS)

    Lin, He; Yao, Chao; Zhang, Xianping; Zhang, Haitao; Wang, Dongliang; Zhang, Qianjun; Ma, Yanwei; Awaji, Satoshi; Watanabe, Kazuo

    2014-03-01

    Improving transport current has been the primary topic for practical application of superconducting wires and tapes. However, the porous nature of powder-in-tube (PIT) processed iron-based tapes is one of the important reasons for low critical current density (Jc) values. In this work, the superconducting core density of ex-situ Sr0.6K0.4Fe2As2 + Sn tapes, prepared from optimized precursors, was significantly improved by employing a simple hot pressing as an alternative route for final sintering. The resulting samples exhibited optimal critical temperature (Tc), sharp resistive transition, small resistivity and high Vickers hardness (Hv) value. Consequently, the transport Jc reached excellent values of 5.1 × 104 A/cm2 in 10 T and 4.3 × 104 A/cm2 in 14 T at 4.2 K, respectively. Our tapes also exhibited high upper critical field Hc2 and almost field-independent Jc. These results clearly demonstrate that PIT pnictide wire conductors are very promising for high-field magnet applications.

  13. Optimal compliance for amblyopia therapy: occlusion with a translucent tape on the lens.

    PubMed

    Beneish, Raquel G; Polomeno, Robert C; Flanders, Michael E; Koenekoop, Robert K

    2009-10-01

    To demonstrate that optimal compliance to amblyopia therapy and a better visual outcome can be achieved by occluding the lens over the preferred eye with a translucent tape. Prospective study of amblyopic children. Eighty-four amblyopic children recruited from 2000 to 2006 at the Montreal Children's Vision Centre. A group of bilateral ametropes (mean age 3.8 years) were treated with glasses and occlusion of the sound eye with a translucent tape on the lens over the preferred eye, or an adhesive patch. The translucent tape reduced vision to hand motion at 0.3 m in the sound eye. Patients were divided into 2 groups depending on the treatment received. Group 1 (n = 36) was occluded with a translucent tape, and group 2 (n = 48) with a conventional adhesive patch, later replaced by the translucent tape. Twenty-five previously reported patients, treated with the conventional adhesive patch only, were used as controls (group 3). The mean amblyopic visual acuity was 20/100-2. Compliance was good in 36 patients (group 1), and was poor or deteriorated in 24/48 patients (group 2). Substituting the adhesive patch with a translucent tape permitted uninterrupted and prolonged occlusion, with a successful visual outcome. The amblyopic eye achieved a significantly better final vision (20/30+2; groups 1+2) than the controls (20/40+1; group 3) (p = 0.04). Sixty-four (76.19%) patients achieved >or=20/30. The translucent tape optimizes compliance and yields better vision by lengthening the duration of occlusion therapy and reducing the number of treatment failures due to noncompliance.

  14. Nanostructured Mo-based electrode materials for electrochemical energy storage.

    PubMed

    Hu, Xianluo; Zhang, Wei; Liu, Xiaoxiao; Mei, Yueni; Huang, Yunhui

    2015-04-21

    The development of advanced energy storage devices is at the forefront of research geared towards a sustainable future. Nanostructured materials are advantageous in offering huge surface to volume ratios, favorable transport features, and attractive physicochemical properties. They have been extensively explored in various fields of energy storage and conversion. This review is focused largely on the recent progress in nanostructured Mo-based electrode materials including molybdenum oxides (MoO(x), 2 ≤ x ≤ 3), dichalconides (MoX2, X = S, Se), and oxysalts for rechargeable lithium/sodium-ion batteries, Mg batteries, and supercapacitors. Mo-based compounds including MoO2, MoO3, MoO(3-y) (0 < y < 1), MMo(x)O(y) (M = Fe, Co, Ni, Ca, Mn, Zn, Mg, or Cd; x = 1, y = 4; x = 3, y = 8), MoS2, MoSe2, (MoO2)2P2O7, LiMoO2, Li2MoO3, etc. possess multiple valence states and exhibit rich chemistry. They are very attractive candidates for efficient electrochemical energy storage systems because of their unique physicochemical properties, such as conductivity, mechanical and thermal stability, and cyclability. In this review, we aim to provide a systematic summary of the synthesis, modification, and electrochemical performance of nanostructured Mo-based compounds, as well as their energy storage applications in lithium/sodium-ion batteries, Mg batteries, and pseudocapacitors. The relationship between nanoarchitectures and electrochemical performances as well as the related charge-storage mechanism is discussed. Moreover, remarks on the challenges and perspectives of Mo-containing compounds for further development in electrochemical energy storage applications are proposed. This review sheds light on the sustainable development of advanced rechargeable batteries and supercapacitors with nanostructured Mo-based electrode materials.

  15. Carbon storage and sequestration by trees in VIT University campus

    NASA Astrophysics Data System (ADS)

    Saral, A. Mary; SteffySelcia, S.; Devi, Keerthana

    2017-11-01

    The present study addresses carbon storage and sequestration by trees grown in VIT University campus, Vellore. Approximately twenty trees were selected from Woodstockarea. The above ground biomass and below ground biomass were calculated. The above ground biomass includes non-destructive anddestructive sampling. The Non-destructive method includes the measurement of height of thetree and diameter of the tree. The height of the tree is calculated using Total Station instrument and diameter is calculated using measuring tape. In the destructive method the weight of samples (leaves) and sub-samples (fruits, flowers) of the tree were considered. To calculate the belowground biomass soil samples are taken and analyzed. The results obtained were used to predict the carbon storage. It was found that out of twenty tree samples Millingtonia hortensis which is commonly known as Cork tree possess maximum carbon storage (14.342kg/tree) and carbon sequestration (52.583kg/tree) respectively.

  16. The INFN-CNAF Tier-1 GEMSS Mass Storage System and database facility activity

    NASA Astrophysics Data System (ADS)

    Ricci, Pier Paolo; Cavalli, Alessandro; Dell'Agnello, Luca; Favaro, Matteo; Gregori, Daniele; Prosperini, Andrea; Pezzi, Michele; Sapunenko, Vladimir; Zizzi, Giovanni; Vagnoni, Vincenzo

    2015-05-01

    The consolidation of Mass Storage services at the INFN-CNAF Tier1 Storage department that has occurred during the last 5 years, resulted in a reliable, high performance and moderately easy-to-manage facility that provides data access, archive, backup and database services to several different use cases. At present, the GEMSS Mass Storage System, developed and installed at CNAF and based upon an integration between the IBM GPFS parallel filesystem and the Tivoli Storage Manager (TSM) tape management software, is one of the largest hierarchical storage sites in Europe. It provides storage resources for about 12% of LHC data, as well as for data of other non-LHC experiments. Files are accessed using standard SRM Grid services provided by the Storage Resource Manager (StoRM), also developed at CNAF. Data access is also provided by XRootD and HTTP/WebDaV endpoints. Besides these services, an Oracle database facility is in production characterized by an effective level of parallelism, redundancy and availability. This facility is running databases for storing and accessing relational data objects and for providing database services to the currently active use cases. It takes advantage of several Oracle technologies, like Real Application Cluster (RAC), Automatic Storage Manager (ASM) and Enterprise Manager centralized management tools, together with other technologies for performance optimization, ease of management and downtime reduction. The aim of the present paper is to illustrate the state-of-the-art of the INFN-CNAF Tier1 Storage department infrastructures and software services, and to give a brief outlook to forthcoming projects. A description of the administrative, monitoring and problem-tracking tools that play a primary role in managing the whole storage framework is also given.

  17. "Space slitter" for film or tape

    NASA Technical Reports Server (NTRS)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  18. Global root zone storage capacity from satellite-based evaporation

    NASA Astrophysics Data System (ADS)

    Wang-Erlandsson, Lan; Bastiaanssen, Wim G. M.; Gao, Hongkai; Jägermeyr, Jonas; Senay, Gabriel B.; van Dijk, Albert I. J. M.; Guerschman, Juan P.; Keys, Patrick W.; Gordon, Line J.; Savenije, Hubert H. G.

    2016-04-01

    This study presents an "Earth observation-based" method for estimating root zone storage capacity - a critical, yet uncertain parameter in hydrological and land surface modelling. By assuming that vegetation optimises its root zone storage capacity to bridge critical dry periods, we were able to use state-of-the-art satellite-based evaporation data computed with independent energy balance equations to derive gridded root zone storage capacity at global scale. This approach does not require soil or vegetation information, is model independent, and is in principle scale independent. In contrast to a traditional look-up table approach, our method captures the variability in root zone storage capacity within land cover types, including in rainforests where direct measurements of root depths otherwise are scarce. Implementing the estimated root zone storage capacity in the global hydrological model STEAM (Simple Terrestrial Evaporation to Atmosphere Model) improved evaporation simulation overall, and in particular during the least evaporating months in sub-humid to humid regions with moderate to high seasonality. Our results suggest that several forest types are able to create a large storage to buffer for severe droughts (with a very long return period), in contrast to, for example, savannahs and woody savannahs (medium length return period), as well as grasslands, shrublands, and croplands (very short return period). The presented method to estimate root zone storage capacity eliminates the need for poor resolution soil and rooting depth data that form a limitation for achieving progress in the global land surface modelling community.

  19. Comparing the diagnostic properties of skin scraping, adhesive tape, and dermoscopy in diagnosing scabies.

    PubMed

    Abdel-Latif, Azmy A; Elshahed, Ahmad R; Salama, Omar A; Elsaie, Mohamed L

    2018-06-01

    Scabies is a contagious skin infestation that mainly presents with itching at night and skin burrows that are visible to the naked eye. Diagnosing scabies with dermoscopy is still a matter of controversy. The aim of our study was to compare the diagnostic properties of adhesive tape, skin scraping, and dermoscopy in diagnosing scabies. One hundred patients with clinical presumptive diagnoses of scabies underwent skin scraping, adhesive tape testing, and dermoscopic examination. Each diagnostic procedure was performed on three different areas. Comparing the diagnostic properties of the three methods, the adhesive tape test was the most sensitive method for diagnosing scabies. Sixteen cases (16.0%) were definitely diagnosed as scabies using the adhesive tape test detecting the presence of mites or their eggs. Only 10 cases (10.0%) were definitely diagnosed as scabies using the skin scraping test detecting mites or their eggs. Dermoscopic examination suggested a diagnosis of scabies in 22 cases (22.0%), of which only 10 were definitely diagnosed as scabies by detecting mites using the adhesive tape test, skin scraping, or both. The diagnosis of scabies can only be confirmed by seeing mites. The adhesive tape test and skin scraping procedure have high specificity in diagnosing scabies, but their low sensitivity cannot exclude the possibility of scabies. Dermoscopy-guided tape testing can be a helpful tool for better diagnosis of scabies.

  20. The Effect of Patellar Taping on Squat Depth and the Perception of Pain in People with Anterior Knee Pain

    PubMed Central

    Clifford, Amanda M.; Harrington, Elaine

    Patellar taping is a treatment adjunct commonly used in the management of anterior knee pain. The aim of this cross sectional study was to investigate the effects of medial glide patellar taping on sagittal plane lower-limb joint kinematics and knee pain during a unilateral squat in a symptomatic population complaining of anterior knee pain. Ten participants with a history of unilateral or bilateral anterior knee pain were included in the study. Subjects were required to squat on the symptomatic leg under three conditions: placebo tape, patellar tape and no tape. Kinematic data was recorded using the CODA mpx64 motion analysis system and subjects’ pain was assessed using the Numerical Rating Scale. Patellar taping resulted in a significantly greater single-legged squat depth compared to placebo tape (p=0.008) and no tape (p=0.001) and a statistically significant reduction in pain during a squat compared to placebo tape (p=0.001) or no tape (p=0.001). Significant differences were not identified for maximum knee flexion in the patella taping compared to the no tape condition. This study may have significant clinical implications as participants reported less pain and alterations in sagittal plane movement following the application of patellar tape. PMID:24146711

  1. FeOx‐Based Materials for Electrochemical Energy Storage

    PubMed Central

    Ma, Jingyi; Guo, Xiaotian; Yan, Yan; Xue, Huaiguo

    2018-01-01

    Abstract Iron oxides (FeOx), such as Fe2O3 and Fe3O4 materials, have attracted much attention because of their rich abundance, low cost, and environmental friendliness. However, FeOx, which is similar to most transition metal oxides, possesses a poor rate capability and cycling life. Thus, FeOx‐based materials consisting of FeOx, carbon, and metal‐based materials have been widely explored. This article mainly discusses FeOx‐based materials (Fe2O3 and Fe3O4) for electrochemical energy storage applications, including supercapacitors and rechargeable batteries (e.g., lithium‐ion batteries and sodium‐ion batteries). Furthermore, future perspectives and challenges of FeOx‐based materials for electrochemical energy storage are briefly discussed.

  2. Synchronisation Technique of Data Recorded on a Multichannel Tape Recorder,

    DTIC Science & Technology

    1984-01-01

    retrieval Synchronizers I 16. Abstract A portable, self-contained, electronic digital unit, termed Data Synchroniser was designed and developed by EDE...AD A139 570 SYNCHRONISATION TECHNIQUE OF DATA RECORDED ON A / OULl ICHANNEL TAPE RECORDER (U) ENGINEERING DEVELOPMENT ESTA B LISHMENT MARIBYRNONO...BGINEERING DEVELOPMEWIT ESTABUSHIMENT S[ SYNCHRONISATION TECHNIQUE OF DATA - i RECORDED ON A MULTICHANNEL TAPE RECORDER BY J.D. DICKENS .t T)TCi j.D. ~c .s

  3. Apparatus and method for loading and unloading multiple digital tape cassettes utilizing a removable magazine

    DOEpatents

    Lindenmeyer, C.W.

    1993-01-26

    An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.

  4. Apparatus and method for loading and unloading multiple digital tape cassettes utilizing a removable magazine

    DOEpatents

    Lindenmeyer, Carl W.

    1993-01-01

    An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.

  5. Technology Solutions Case Study: Guidance on Taped Insulating Sheathing Drainage Planes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The energy efficiency-based financial benefits of adding exterior insulation are well accepted by the building industry, and using exterior insulation as the drainage plane is the next logical step. This case study focuses on the field implementation of taped board insulation as the drainage plane in both new and retrofit residential applications, and provides information and recommendations for insulation contractors, general contractors, builders, remodelers, mechanical contractors, and homeowners. The order of work completed during home construction and retrofit improvements is important. Health and safety issues must be addressed first and are more important than durability issues, and durability issues aremore » more important than saving energy. Three significant items are required to make taped insulating sheathing a simple, long term, and durable drainage plane: first, horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists, use superior materials; and, frequent installation inspection and regular trade training are required to maintain proper installation.« less

  6. Excess current experiment on YBCO tape conductor with metal stabilized layer

    NASA Astrophysics Data System (ADS)

    Tasaki, Kenji; Yazawa, Takashi; Ono, Michitaka; Kuriyama, Toru

    2006-06-01

    Excess current experiments were performed using YBCO tape conductors with a metal stabilized layer on the superconducting layer. The purpose of this research is to obtain the stable criteria of energy dissipation when YBCO tape is forced to flow excess current higher than its critical current. This situation should be considered in power applications. In the experiments short-length samples were immersed in liquid nitrogen and several cycles of 50Hz sinusoidal current were supplied to the samples by an induction voltage regulator. The critical current of the samples was about 110 A. With pulse length as long as 60 ms, YBCO tapes were able to be energized up to twelve times as the critical current without electrical or mechanical deformation. Prior to the excess current experiments, temperature dependency of resistance of the sample was measured so that the temperature rise was estimated by the generated resistance. It is found that YBCO tapes with a copper stabilized layer can be transiently heated to over 400K without degradation.

  7. Portable and Error-Free DNA-Based Data Storage.

    PubMed

    Yazdi, S M Hossein Tabatabaei; Gabrys, Ryan; Milenkovic, Olgica

    2017-07-10

    DNA-based data storage is an emerging nonvolatile memory technology of potentially unprecedented density, durability, and replication efficiency. The basic system implementation steps include synthesizing DNA strings that contain user information and subsequently retrieving them via high-throughput sequencing technologies. Existing architectures enable reading and writing but do not offer random-access and error-free data recovery from low-cost, portable devices, which is crucial for making the storage technology competitive with classical recorders. Here we show for the first time that a portable, random-access platform may be implemented in practice using nanopore sequencers. The novelty of our approach is to design an integrated processing pipeline that encodes data to avoid costly synthesis and sequencing errors, enables random access through addressing, and leverages efficient portable sequencing via new iterative alignment and deletion error-correcting codes. Our work represents the only known random access DNA-based data storage system that uses error-prone nanopore sequencers, while still producing error-free readouts with the highest reported information rate/density. As such, it represents a crucial step towards practical employment of DNA molecules as storage media.

  8. User's guide for the Nimbus 7 ERB Solar Analysis Tape (ESAT)

    NASA Technical Reports Server (NTRS)

    Hickey, J. R.; Major, E. R.; Kyle, H. L.

    1984-01-01

    Five years of Nimbus 7 ERB solar data is available in compact form on a single ERB solar analysis tape (ESAT). The period covered is November 16, 1978 through October 31, 1983. The Nimbus 7 satellite performs just under 14 orbits a day and the ERB solar telescope observe the Sun once per orbit as the satellite passes + or - near the south pole. The data were carefully calibrated and screened. Mean orbital and daily values are given for the total solar irradiance plus selected spectral intervals. In addition, selected solar activity indicators are on the tape. The ERB experiment, the solar data calibration and screening procedures, the solar activity indicators, and the tape format are described briefly.

  9. An analysis of the surface-normal coupling efficiency of a metal grating coupler embedded in a Scotch tape optical waveguide

    NASA Astrophysics Data System (ADS)

    Barrios, Carlos Angulo; Canalejas-Tejero, Víctor

    2017-01-01

    The coupling efficiency at normal incidence of recently demonstrated aluminum grating couplers integrated in flexible Scotch tape waveguides has been analyzed theoretically and experimentally. Finite difference time domain (FDTD) and rigorously coupled wave analysis (RCWA) methods have been used to optimize the dimensions (duty cycle and metal thickness) of Scotch tape-embedded 1D Al gratings for maximum coupling at 635 nm wavelength. Good dimension and tape refractive index tolerances are predicted. FDTD simulations reveal the incident beam width and impinging position (alignment) values that avoid rediffraction and thus maximize the coupling efficiency. A 1D Al diffraction grating integrated into a Scotch tape optical waveguide has been fabricated and characterized. The fabrication process, based on pattern transfer, has been optimized to allow complete Al grating transfer onto the Scotch tape waveguide. A maximum coupling efficiency of 20% for TM-polarized normal incidence has been measured, which is in good agreement with the theoretical predictions. The measured coupling efficiency is further increased up to 28% for TM polarization under oblique incidence. Temperature dependence measurements have been also achieved and related to the simulations results and fabrication procedure.

  10. Design and evaluation of a computer based system to monitor and generalise, by areas, data from ERTS precision imagery tapes

    NASA Technical Reports Server (NTRS)

    Clayton, K. M. (Principal Investigator)

    1975-01-01

    The author has identified the following significant results. An objective system for regionalization is described, using ERTS-1 (or LANDSAT) computer compatible tapes. A range of computer programs for analysis of these tapes was developed. Emphasis is on a level of generalization appropriate to a satellite system whith repetitive global coverage. The main variables are land/water ratios and vegetation cover. The scale or texture of the pattern of change in these variables varies a good deal across the earth's surface, and it seems best if the unit of generalization adopted varies in sympathy with the surface being analyzed.

  11. Adsorption of dispersants on zirconia powder in tape-casting slip compositions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richards, V.L. II

    This paper reports the determination of adsorption isotherms for menhaden fish oil and glycerol trioleate on doped zirconia powder in solvents composed of 70% methyl ethyl ketone (MEK) and 30% ethanol. In order to approach tape-casting zirconia on a sound technical basis, the correspondence of slip viscosities and tape sintered densities to the adsorption isotherms was studied.

  12. Heat reflecting tape for thermoelectric converter

    DOEpatents

    Purdy, David L.

    1977-01-01

    Threads are interlaced with thermoelectric wires to provide a woven cloth in tape form, there being an intermediate layer of heat radiation reflecting material (e.g., aluminum foil) insulated electrically from said wires, which are of opposite thermoelectric polarity and connected as a plurality of thermocouples.

  13. Effects of Taping and Orthoses on Foot Biomechanics in Adults with Flat-Arched Feet.

    PubMed

    Bishop, Christopher; Arnold, John B; May, Thomas

    2016-04-01

    There is a paucity of evidence on the biomechanical effects of foot taping and foot orthoses in realistic conditions. This study aimed to determine the immediate effect and relationships between changes in multisegment foot biomechanics with foot taping and customized foot orthoses in adults with flat-arched feet. Multisegment foot biomechanics were measured in 18 adults with flat-arched feet (age 25.1 ± 2.8 yr; height 1.73 ± .13 m, body mass 70.3 ± 15.7 kg) during walking in four conditions in random order: neutral athletic shoe, neutral shoe with tape (low-Dye method and modified method) and neutral shoe with customized foot orthoses. In-shoe foot biomechanics were compared between conditions using a purpose developed foot model with three-dimensional kinematic analysis and inverse dynamics. Foot orthoses significantly delayed peak eversion compared to the neutral shoe (44% stance vs 39%, P = 0.002). Deformation across the midfoot and medial longitudinal arch was reduced with both the low-Dye taping (2.4°, P < 0.001) and modified taping technique (5.5°, P < 0.001). All interventions increased peak dorsiflexion of the first metatarsophalangeal joint (1.4°-3.2°, P < 0.001-0.023). Biomechanical responses to taping significantly predicted corresponding changes to foot orthoses (R2 = 0.08-0.52, P = 0.006 to <0.001). Foot orthoses more effectively altered timing of hindfoot motion whereas taping was superior in supporting the midfoot and medial longitudinal arch. The biomechanical response to taping was significantly related to the subsequent change observed with the use of foot orthoses.

  14. Magnetic and Electrical Characteristics of Permalloy Thin Tape Bobbin Cores

    NASA Technical Reports Server (NTRS)

    Schwarze, Gene E.; Wieserman, William R.; Niedra, Janis M.

    2005-01-01

    The core loss, that is, the power loss, of a soft ferromagnetic material is a function of the flux density, frequency, temperature, excitation type (voltage or current), excitation waveform (sine, square, etc.) and lamination or tape thickness. In previously published papers we have reported on the specific core loss and dynamic B-H loop results for several polycrystalline, nanocrystalline, and amorphous soft magnetic materials. In this previous research we investigated the effect of flux density, frequency, temperature, and excitation waveform for voltage excitation on the specific core loss and dynamic B-H loop. In this paper, we will report on an experimental study to investigate the effect of tape thicknesses of 1, 1/2, 1/4, and 1/8-mil Permalloy type magnetic materials on the specific core loss. The test cores were fabricated by winding the thin tapes on ceramic bobbin cores. The specific core loss tests were conducted at room temperature and over the frequency range of 10 kHz to 750 kHz using sine wave voltage excitation. The results of this experimental investigation will be presented primarily in graphical form to show the effect of tape thickness, frequency, and magnetic flux density on the specific core loss. Also, the experimental results when applied to power transformer design will be briefly discussed.

  15. Fabrication Of Carbon-Boron Reinforced Dry Polymer Matrix Composite Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Treasure, Monte; Shahood, Thomas W.

    1999-01-01

    Future generation aerospace vehicles will require specialized hybrid material forms for component structure fabrication. For this reason, high temperature composite prepregs in both dry and wet forms are being developed at NASA Langley Research Center (LaRC). In an attempt to improve compressive properties of carbon fiber reinforced composites, a hybrid carbon-boron tape was developed and used to fabricate composite laminates which were subsequently cut into flexural and compression specimens and tested. The hybrid material, given the designation HYCARB, was fabricated by modifying a previously developed process for the manufacture of dry polymer matrix composite (PMC) tape at LaRC. In this work, boron fibers were processed with IM7/LaRC(TradeMark)IAX poly(amide acid) solution-coated prepreg to form a dry hybrid tape for Automated Tow Placement (ATP). Boron fibers were encapsulated between two (2) layers of reduced volatile, low fiber areal weight poly(amide acid) solution-coated prepreg. The hybrid prepreg was then fully imidized and consolidated into a dry tape suitable for ATP. The fabrication of a hybrid boron material form for tow placement aids in the reduction of the overall manufacturing cost of boron reinforced composites, while realizing the improved compression strengths. Composite specimens were press-molded from the hybrid material and exhibited excellent mechanical properties.

  16. Comparison of gravimetric and spectroscopic approaches to quantify stratum corneum removed by tape-stripping.

    PubMed

    Mohammed, D; Yang, Q; Guy, R H; Matts, P J; Hadgraft, J; Lane, M E

    2012-09-01

    Skin surface tape-stripping is an extensively used technique to examine the distribution profile, penetration and safety of various active compounds. It is also a widely accepted method to probe skin barrier properties and more specifically, those of the stratum corneum (SC). The amount of SC removed by tape-stripping is generally determined either gravimetrically or by extraction and measurement of SC proteins. A novel infra-red densitometry (IRD) technique has recently been introduced to measure SC protein content. In the present study, IRD was investigated as an alternative method to measure the mass of SC removed by tape-stripping. Tape-stripping experiments were conducted on human volunteers. The weight of the stratum corneum removed was assessed by the gravimetric approach and by IRD. Transepidermal water loss (TEWL) was also measured before and after each tape-strip. A linear correlation coefficient was obtained for the data from the gravimetric and IRD measurements (r(2)=0.65; n=240). IRD is therefore proposed as a rapid, non-destructive alternative to the gravimetric approach to estimate the amount of SC removed by tape-stripping in vivo. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Heat storage with an incongruently melting salt hydrate as storage medium based on the extra water principle

    NASA Astrophysics Data System (ADS)

    Furbo, S.

    1980-12-01

    The extra water principle, a heat of fusion storage method, is described. The extra water principle uses an inorganic, incongruently melting salt hydrate as a reliable and stable storage medium in an inexpensive way. Different heat storages using the extra water principle are described. The advantages of using a heat fusion storage unit based on Na2S2O(3).5H2O and the extra water principle instead of a traditional hot water tank in small solar heating systems for domestic hot water supply are shown. In small solar heating systems the heat fusion storage supplies all the wanted hot water in the summer during longer periods than an ordinary hot water storage. It is concluded that the heat of fusion storage is favourable in domestic hot water supply systems with an auxiliary energy source which during the summer have a large energy consumption compared with the energy demands for the hot water supply.

  18. ERB master archival tape specification no. T 134081 ERB MAT, revision 1

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The Earth radiation budget (ERB)MAT tapes are generated by the ERB MATGEN software using the IBM 3081 computer system operated by the Science and Applications Computer Center at Goddard Space Flight Center. All MAT's are 9-track and MAT data are in ascending time order. The gross tape format for NIMBUS year-1 and year-2 MAT's is different from the format of MAT's starting with year-3. The MATs from the first two years are to contain one day's worth of data while all other MATs are to contain multiple day's worth of data stacked onto the tapes.

  19. Non-contact inline monitoring of thermoplastic CFRP tape quality using air-coupled ultrasound

    NASA Astrophysics Data System (ADS)

    Essig, W.; Fey, P.; Meiler, S.; Kreutzbruck, M.

    2017-02-01

    Beginning with the aerospace industry, fiber reinforced plastics have spread towards many applications such as automotive, civil engineering as well as sports and leisure articles. Their superior strength and stiffness to mass ratio made them the number one material for achieving high performance. Especially continuous fiber reinforced plastics allow for the construction of structures which are custom tailored to their mechanical loads by adjusting the paths of the fibers to the loading direction. The two main constituents of CFRP are carbon fibers and matrix. Two possibilities for matrix material exist: thermosetting and thermoplastic matrix. While thermosetting matrix may yield better properties with respect to thermal loads, thermoplasticity opens a wide range of applications due to weldability, shapeability, and compatibility to e.g. injection molded thermoplastic materials. Thin (0.1 mm) thermoplastic continuous fiber CFRP tapes with a width of 100 mm were examined using air-coupled ultrasound. Transducers were arranged in reflection as well as transmission setup. By slanted incidence of the ultrasound on the tape surface, guided waves were excited in the material in fiber direction and perpendicular to the fiber direction. Artificial defects - fiber cuts, matrix cuts, circular holes, low velocity impacts from tool drop, and sharp bends - were produced. Experiments on a stationary tape showed good detectability of all artificial defects by guided waves. Also the effects of variation in material properties, fiber volume content and fiber matrix adhesion being the most relevant, on guided wave propagation were examined, to allow for quality assessment. Guided wave measurements were supported by destructive analysis. Also an apparatus containing one endless loop of CFRP tape was constructed and built to simulate inline testing of CFRP tapes, as it would be employed in a CFRP tape production environment or at a CFRP tape processing facility. The influences of tape

  20. Properties of pressure-sensitive adhesive tapes with soft adhesives to human skin and their mechanism.

    PubMed

    Tokumura, Fumio; Homma, Takeyasu; Tomiya, Toshiki; Kobayashi, Yuko; Matsuda, Tetsuaki

    2007-05-01

    The use of soft adhesives in the manufacture of pressure-sensitive adhesive tapes has recently increased. The dermal peeling force of adhesive tapes with soft adhesives was studied. Four kinds of adhesive tapes with adhesives of different softness were made, by adding varying amounts of isopropyl myristate as a softener. The tapes were applied on the flexor side of the forearm of six healthy male volunteers. The dermal peeling force, the amount of stripped corneocytes, the level of pain when the tapes were removed and the degree of penetration of adhesives into the sulcus cutis (skin furrows) were evaluated at 1 and 24 h after application of the tapes. Furthermore, a skin model panel (a sulcus cutis and crista cutis model panel) and a crista cutis model panel were constructed from a general stainless-steel panel, and the peeling force of the tapes against the model panels was measured. As the softness of adhesives increased, the peeling force against a general stainless-steel panel with a flat surface decreased, although the peeling force against human skin did not significantly change. The amount of stripped corneocytes on the removed tapes and the level of pain when the tapes were removed decreased with the increase in softness of the adhesives. These results suggest that adhesive tapes with soft adhesives that contain isopropyl myristate as a softener are suitable for the skin. Furthermore, the degree of penetration of adhesive into the sulcus cutis increased as the softness of adhesives increased. Upon evaluation of the peeling force against the model panels, as the softness of adhesives increased, there was a slight decrease in the peeling force against the skin model panel, while there was a remarkable decrease in the peeling force against the crista cutis model panel. These results suggest that the lack of change in the dermal peeling force as the softness of adhesives increased was caused by penetration of soft adhesive into the sulcus cutis, and that the

  1. Embedded system of image storage based on fiber channel

    NASA Astrophysics Data System (ADS)

    Chen, Xiaodong; Su, Wanxin; Xing, Zhongbao; Wang, Hualong

    2008-03-01

    In domains of aerospace, aviation, aiming, and optic measure etc., the embedded system of imaging, processing and recording is absolutely necessary, which has small volume, high processing speed and high resolution. But the embedded storage technology becomes system bottleneck because of developing slowly. It is used to use RAID to promote storage speed, but it is unsuitable for the embedded system because of its big volume. Fiber channel (FC) technology offers a new method to develop the high-speed, portable storage system. In order to make storage subsystem meet the needs of high storage rate, make use of powerful Virtex-4 FPGA and high speed fiber channel, advance a project of embedded system of digital image storage based on Xilinx Fiber Channel Arbitrated Loop LogiCORE. This project utilizes Virtex- 4 RocketIO MGT transceivers to transmit the data serially, and connects many Fiber Channel hard drivers by using of Arbitrated Loop optionally. It can achieve 400MBps storage rate, breaks through the bottleneck of PCI interface, and has excellences of high-speed, real-time, portable and massive capacity.

  2. Ankle taping can reduce external ankle joint moments during drop landings on a tilted surface.

    PubMed

    Sato, Nahoko; Nunome, Hiroyuki; Hopper, Luke S; Ikegami, Yasuo

    2017-09-20

    Ankle taping is commonly used to prevent ankle sprains. However, kinematic assessments investigating the biomechanical effects of ankle taping have provided inconclusive results. This study aimed to determine the effect of ankle taping on the external ankle joint moments during a drop landing on a tilted surface at 25°. Twenty-five participants performed landings on a tilted force platform that caused ankle inversion with and without ankle taping. Landing kinematics were captured using a motion capture system. External ankle inversion moment, the angular impulse due to the medio-lateral and vertical components of ground reaction force (GRF) and their moment arm lengths about the ankle joint were analysed. The foot plantar inclination relative to the ground was assessed. In the taping condition, the foot plantar inclination and ankle inversion angular impulse were reduced significantly compared to that of the control. The only component of the external inversion moment to change significantly in the taped condition was a shortened medio-lateral GRF moment arm length. It can be assumed that the ankle taping altered the foot plantar inclination relative to the ground, thereby shortening the moment arm of medio-lateral GRF that resulted in the reduced ankle inversion angular impulse.

  3. The effect of kinesio taping in forward bending of the lumbar spine.

    PubMed

    Lemos, Thiago Vilela; Albino, Anna Carolina Gonçalves; Matheus, Joao Paulo C; Barbosa, Aurélio de Melo

    2014-09-01

    [Purpose] The aim of this study was to evaluate the influence of a lumbar fascia Kinesio Taping(®) technique forward bending range of motion. [Subjects and Methods] This was a longitudinal study with a randomized clinical trial composed of 39 subjects divided into three groups (control, Kinesio Without Tension-KWT, and Kinesio Fascia Correction-KFC). The subjects were assessed by Schober and fingertip-to-floor tests and left the tape in place for 48 hours before being reassessed 24 hours, 48 hours and 30 days after its removal. [Results] In all three experimental groups no significant differences were observed with the Schober test, but it was possible to observe an increase in lumbar flexion after 30 days. With the fingertip-to-floor distance assessment, the KFC and KWT groups showed significantly improved flexibility 24 hours and 48 hours after tape removal. [Conclusion] The Kinesio Taping(®) influenced fascia mobility, allowing for slight improvement of lumbar flexibility.

  4. The Effect of Kinesio Taping in Forward Bending of the Lumbar Spine

    PubMed Central

    Lemos, Thiago Vilela; Albino, Anna Carolina Gonçalves; Matheus, Joao Paulo C.; Barbosa, Aurélio de Melo

    2014-01-01

    [Purpose] The aim of this study was to evaluate the influence of a lumbar fascia Kinesio Taping® technique forward bending range of motion. [Subjects and Methods] This was a longitudinal study with a randomized clinical trial composed of 39 subjects divided into three groups (control, Kinesio Without Tension-KWT, and Kinesio Fascia Correction-KFC). The subjects were assessed by Schober and fingertip-to-floor tests and left the tape in place for 48 hours before being reassessed 24 hours, 48 hours and 30 days after its removal. [Results] In all three experimental groups no significant differences were observed with the Schober test, but it was possible to observe an increase in lumbar flexion after 30 days. With the fingertip-to-floor distance assessment, the KFC and KWT groups showed significantly improved flexibility 24 hours and 48 hours after tape removal. [Conclusion] The Kinesio Taping® influenced fascia mobility, allowing for slight improvement of lumbar flexibility. PMID:25276018

  5. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    PubMed

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair

  6. The effects of therapeutic taping on gross motor function in children with cerebral palsy.

    PubMed

    Footer, Cheryl Burditt

    2006-01-01

    Therapeutic taping to address dysfunctional sitting control in children with cerebral palsy (CP) was investigated in this study. Eighteen children with quadriplegic CP, Gross Motor Function Classification System for Cerebral Palsy levels IV (n = 9) and V (n = 9) participated in the 12-week program. Subjects were assigned randomly to one of two groups: therapeutic taping + physical therapy or physical therapy only. Therapeutic taping was applied for periods of up to 72 hours over the paraspinal region. The effects were assessed with the Gross Motor Function Measure (GMFM-88) at baseline, six weeks, and 12 weeks. A factorial analysis of variance was used to examine group differences over time. No significant differences were found for the GMFM-88 scores between groups over time. Therapeutic taping does not evoke a positive functional change in the seated postural control of children with quadriplegic cerebral palsy. Subjective observation, however, suggested that one child with athetosis benefited from therapeutic taping over the paraspinal region.

  7. New insights into designing metallacarborane based room temperature hydrogen storage media.

    PubMed

    Bora, Pankaj Lochan; Singh, Abhishek K

    2013-10-28

    Metallacarboranes are promising towards realizing room temperature hydrogen storage media because of the presence of both transition metal and carbon atoms. In metallacarborane clusters, the transition metal adsorbs hydrogen molecules and carbon can link these clusters to form metal organic framework, which can serve as a complete storage medium. Using first principles density functional calculations, we chalk out the underlying principles of designing an efficient metallacarborane based hydrogen storage media. The storage capacity of hydrogen depends upon the number of available transition metal d-orbitals, number of carbons, and dopant atoms in the cluster. These factors control the amount of charge transfer from metal to the cluster, thereby affecting the number of adsorbed hydrogen molecules. This correlation between the charge transfer and storage capacity is general in nature, and can be applied to designing efficient hydrogen storage systems. Following this strategy, a search for the best metallacarborane was carried out in which Sc based monocarborane was found to be the most promising H2 sorbent material with a 9 wt.% of reversible storage at ambient pressure and temperature.

  8. Inefficacy of Kinesio-Taping(®) on early postoperative pain after ACL reconstruction: Prospective comparative study.

    PubMed

    Laborie, M; Klouche, S; Herman, S; Gerometta, A; Lefevre, N; Bohu, Y

    2015-12-01

    Kinesio-Taping(®) (K-Tape) is used in sports traumatology with the aim of reducing pain and improving blood and lymph circulation. The main objective of the present study was to assess the efficacy of K-Tape on early postoperative pain after anterior cruciate ligament (ACL) reconstruction. The study hypothesis was that K-Tape significantly decreases pain. A prospective non-randomized comparative study was conducted in 2013-2014 and included all patients who underwent primary ACL reconstruction by hamstring graft. Analgesia was standardized. Two groups, "K-Tape" and "controls", were formed according to the days on which the study physiotherapist was present. The K-Tape compression/decompression assembly was applied immediately postoperatively and maintained for 3days. Patients filled out online questionnaires. The main assessment criterion was mean postoperative pain (D0-D3) on a 0-to-10 scale. Secondary criteria were analgesia intake on the three WHO levels, awakening during the night of D0 due to pain, signs of postoperative discomfort, and patient satisfaction. Sixty patients (30 per group) were included, 57 of whom could be assessed: 28 K-Tape, 29 controls; 44 male, 13 female; mean age, 30.9±8.9 years. At inclusion, the two groups were comparable. There was no significant difference in mean (D0-D3) knee pain intensity: 3.8±2.2 for K-Tape, and 3.9±2 for controls (P=0.93). Analysis of variance (ANOVA) found no significant intergroup difference in evolution of pain (P=0.34). There were no other significant differences on the other assessment criteria. K-Tape showed no efficacy on early postoperative pain following ACL reconstruction. III; prospective non-randomized comparative study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  9. Transport performance of a HTS current lead prepared by the TFA-MOD processed YBCO tapes

    NASA Astrophysics Data System (ADS)

    Shiohara, K.; Sakai, S.; Ohki, S.; Yamada, Y.; Tachikawa, K.; Koizumi, T.; Aoki, Y.; Hikichi, Y.; Nishioka, J.; Hasegawa, T.

    2009-10-01

    A superconducting current lead has been prepared using 12 tapes of the trifluoroacetates - metal organic deposition (TFA-MOD) processed Y 1Ba 2Cu 3O 7-δ (YBCO) coated conductors with critical current ( I c) of about 100 A at 77 K in self-field. The tapes are 4.5 mm in width, 220 mm in length and about 120 μm in overall thickness. The 1 μm thick superconducting YBCO layer was formed through the TFA-MOD process on Hastelloy TM substrate tapes with two buffer oxide layers of Gd 2Zr 2O 7 (GZO) and CeO 2. The 12 YBCO tapes were arrayed on the both sides (six tapes on each side) of a stainless steel board with 3 mm in thickness for a board type shape. They were similarly soldered to copper caps at the both ends. The transport current of 1000 A was stably applied for 10 min in the liquid nitrogen temperature without any voltage generation in all tapes. Although some voltage in some YBCO tapes generated at the applied currents of about 1100 A, the transport current of 1200 A was successfully applied without quenching. The voltage between both copper caps linearly increased with increasing the transport current, and it was about 300 μV at an applied current of 1000 A. A low joint resistance between the YBCO tapes and the copper caps resulted in small amounts of the Joule heating at the joints when 1000 A was applied. The overall (effective) thermal conductivity of the current leads composed of YBCO tapes and the stainless steel board was much lower than that of Non-superconducting current leads. Therefore, the present current leads with small heat leakage seemed to be practically promising for superconducting magnets.

  10. TECHNIQUES OF TAPE PREPARATION AND DUPLICATION, WITH SUGGESTIONS FOR A LANGUAGE LABORATORY.

    ERIC Educational Resources Information Center

    Kansas State Dept. of Public Instruction, Topeka.

    PART ONE OF THIS BULLETIN PROVIDES HELP IN THE TWO CRITICAL AREAS OF MASTER TAPE PREPARATION AND DUPLICATION. SUPPLEMENTED BY NUMEROUS PHOTOGRAPHS AND DIAGRAMS OF EQUIPMENT AND DUPLICATION TECHNIQUES, THE BULLETIN DESCRIBES MASTER PROGRAM DUPLICATION USING LANGUAGE LABORATORY EQUIPMENT, A PROFESSIONAL MASS DUPLICATOR, A TAPE RECORDER, A RECORD…

  11. An Analysis of Certain Elements of an Audio-Tape Approach to Instruction.

    ERIC Educational Resources Information Center

    Bell, Ronald Ernest

    This study was designed to determine the association between selected variables and an audio-tape approach to instruction. Fifty sophomore students enrolled in a physical anthropology course at Shoreline Community College (Washington) participated in an experimental instructional program that consisted of thirty-two audio-tapes and three optional…

  12. Malignant mesothelioma due to asbestos exposure in dental tape.

    PubMed

    Markowitz, Steven B; Moline, Jacqueline M

    2017-05-01

    Although most cases of malignant mesothelioma of the pleura are caused by one or more readily recognized sources of exposure to asbestos, cases of the disease with more occult exposure occur, especially since asbestos has been used in over 3,000 products. Dental lining tape contained asbestos from the 1930s until at least the 1970s and was used in the lost wax method of casting crowns, bridges, and other metal dental prosthetic devices. We report six cases of pathology-verified malignant mesothelioma, mostly among dentists, following exposure to airborne dust from asbestos dental tape, which resulted in asbestos tort litigation. According to evidence available at present, chrysotile asbestos was the type of asbestos used in dental tape in the past in the United States, and the described cases followed relatively brief and intermittent exposure to this type of asbestos. These cases underscore the need for comprehensive exposure histories to determine exposure scenarios. Am. J. Ind. Med. 60:437-442, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  13. Ankle Ranges of Motion During Extended Activity Periods While Taped and Braced

    PubMed Central

    Paris, David L.; Kokkaliaris, Jimmy; Vardaxis, Vassilios

    1995-01-01

    Tape has traditionally been used to support the ankle during activity. More recently, commercial ankle braces have been worn as an alternative. The cumulative information on the effects of taped versus braced ankle support or interbrace comparisons is inconclusive. With few exceptions, ankle brace studies have collected data soon after support conditions were administered. Plantar-dorsiflexion and inversion-eversion ranges of motion (ROM) of 30 subjects were compared under conditions of unsupported, nonelastic adhesivetaped, and Swede-O and Sub Talar Support-braced ankles. We recorded measurements before activity and after periods of 15, 30, 45, and 60 minutes of selected activity on a motorized treadmill. All support conditions significantly reduced preactivity ROM in all directions compared to unsupported ankles. Results showed that the ankle significantly increased in plantarflexion ROM 15 minutes after the initiation of activity with tape or the SubTalar Support-brace, and after 30 minutes with the Swede-O brace. Tape showed further significant increases in plantarflexion ROM after 15-minute intervals of 30, 45, and 60 minutes of activity. All three support conditions had increased significantly in inversion ROM by 15 minutes of activity. The SubTalar Support brace showed a further significant inversion ROM increase between 15 and 30 minutes postactivity. We conclude that the Swede-O and SubTalar Support braces and tape offer significant preactivity ankle support in all four directions of movement. We also conclude that both braces offer longer postactivity support than tape. In inversion ROM and plantarflexion ROM, actions prevalent in ankle sprains, the Swede-O brace retained support longer than the SubTalar Support brace. ImagesFig 1.Fig 2.Fig 3. PMID:16558340

  14. Uniform GTD solution for the diffraction by metallic tapes on panelled compact-range reflectors

    NASA Technical Reports Server (NTRS)

    Somers, G. A.; Pathak, P. H.

    1992-01-01

    Metallic tape is commonly used to cover the interpanel gaps which occur in paneled compact-range reflectors. It is therefore of interest to study the effect of the scattering by the tape on the field in the target zone of the range. An analytical solution is presented for the target zone fields scattered by 2D metallic tapes. It is formulated by the generalized scattering matrix technique in conjunction with the Wiener-Hopf procedure. An extension to treat 3D tapes can be accomplished using the 2D solution via the equivalent current concept. The analytical solution is compared with a reference moment method solution to confirm the accuracy of the former.

  15. The redwood project: An overview

    NASA Technical Reports Server (NTRS)

    Cheatham, Sam

    1993-01-01

    Redwood is a new generation tape subsystem now under development at StorageTek using helical scan technology. This library based storage subsystem is designed for the high performance, deep archival market. The topics are presented in viewgraph form and include the following: subsystem overview, media standards, Redwood developed tape, D3 helical recording format, Redwood cartridge, host software for Redwood libraries, and market opportunities.

  16. Characterization of Enterobius vermicularis in a human population, employing a molecular-based method from adhesive tape samples.

    PubMed

    Piperaki, Evangelia-Theophano; Spanakos, Gregory; Patsantara, Giannoula; Vassalou, Evdokia; Vakalis, Nikolaos; Tsakris, Athanassios

    2011-01-01

    Human infection with the parasitic nematode Enterobius vermicularis occurs worldwide, particularly in children. Although its prevalence may exceed 35% in some parts of the world, molecular studies of E. vermicularis in humans are limited. The aim of the present study was to investigate the genetic variation within E. vermicularis in a human population. For this purpose, 77 adhesive tape samples taken from Greek children infested with E. vermicularis were tested. New primers were designed to amplify a segment of the mitochondrial cytochrome c oxidase subunit 1 (cox1) gene of E. vermicularis from adhesive tape samples. Thirty-six amplicons were sequenced and eleven different haplotypes were identified. All sequences clustered within the type previously characterized (type B), only reported to date from captive chimpanzees. To the best of our knowledge, this is the first study of E. vermicularis genotypes from a human population. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Prediction of the Long Term Stability of Polyester-Based Recording Media. First Annual Report, June 1982; Second Annual Report, August 1983; Progress Report, December 1984.

    ERIC Educational Resources Information Center

    Brown, Daniel W.; And Others

    This document comprises three progress reports for a 5-year environmental aging study aimed at establishing the lifetimes of magnetic tapes and the poly(ethylene terephthalate) (PET) base of photographic and electronic film under archival storage conditions. The first annual report (1982) introduces the rationale for the project, provides…

  18. Extended use of Kinesiology Tape and Balance in Participants with Chronic Ankle Instability.

    PubMed

    Jackson, Kristen; Simon, Janet E; Docherty, Carrie L

    2016-01-01

    Participants with chronic ankle instability (CAI) have been shown to have balance deficits related to decreased proprioception and neuromuscular control. Kinesiology tape (KT) has been proposed to have many benefits, including increased proprioception. To determine if KT can help with balance deficits associated with CAI. Cohort study. Research laboratory. Thirty participants with CAI were recruited for this study. Balance was assessed using the Balance Error Scoring System (BESS). Participants were pretested and then randomly assigned to either the control or KT group. The participants in the KT group had 4 strips applied to the foot and lower leg and were instructed to leave the tape on until they returned for testing. All participants returned 48 hours later for another BESS assessment. The tape was then removed, and all participants returned 72 hours later to complete the final BESS assessment. Total BESS errors. Differences between the groups occurred at 48 hours post-application of the tape (mean difference = 4.7 ± 1.4 errors, P < .01; 95% confidence interval = 2.0, 7.5) and at 72 hours post-removal of the tape (mean difference = 2.3 ± 1.1 errors, P = .04; 95% confidence interval = 0.1, 4.6). The KT improved balance after it had been applied for 48 hours when compared with the pretest and with the control group. One of the most clinically important findings is that balance improvements were retained even after the tape had been removed for 72 hours.

  19. THE EFFECT OF KINESIO® TAPE ON VERTICAL JUMP AND DYNAMIC POSTURAL CONTROL

    PubMed Central

    Baldridge, Carolann

    2013-01-01

    Introduction and Background: Ankle injuries are one of the most common injuries among physically active individuals. The role of prophylactic ankle taping and bracing has been studied extensively. Kinesio® Tape (KT) is a somewhat new type of taping technique gaining popularity as both treatment and performance enhancement tool. However, there is limited research on the effect of KT on functional performance. Purpose: The purpose of this study was to determine whether the application of Kinesio Tex® Tape had an effect on vertical jump and dynamic postural control in healthy young individuals. Methods: 52 healthy subjects free of ankle or lower extremity problems (28 males and 24 females; age: 22.12±2.08 years; height: 170.77±8.69 cm; weight: 69.90±12.03 kg) participated in the study. Subjects were randomly assigned to either the experimental group (KT with tension) or the control group (KT without tension). Vertical jump was measured using the VertiMetric device and dynamic postural control was assessed using the Star Excursion Balance Test (SEBT) under three conditions: (1) without taping; (2) immediately after taping; (3) 24 hours after taping with the taping remaining in situ. Results: Three-way repeated measure ANOVA was conducted in order to identify differences between the experimental and the control group during the three conditions. Overall, there were no differences between groups in vertical jump maximum height, vertical jump average height, or the SEBT scores for the three time periods (pre-test, post-test, 24hrs-post-test). However, the main effect of KT was moderated by a significant gender interaction, resulting in a statistically significant effect of KT for the SEBT scores in the posterior-medial direction, F(1.72, 82.57) = 4.50, p = 0.018 and the medial direction, F(1.75, 83.81) = 4.27, p = 0.021. Follow-up analyses indicated that female subjects in the KT group had increased SEBT scores between three time periods when compared to the placebo

  20. The growth of the UniTree mass storage system at the NASA Center for Computational Sciences: Some lessons learned

    NASA Technical Reports Server (NTRS)

    Tarshish, Adina; Salmon, Ellen

    1994-01-01

    In October 1992, the NASA Center for Computational Sciences made its Convex-based UniTree system generally available to users. The ensuing months saw growth in every area. Within 26 months, data under UniTree control grew from nil to over 12 terabytes, nearly all of it stored on robotically mounted tape. HiPPI/UltraNet was added to enhance connectivity, and later HiPPI/TCP was added as well. Disks and robotic tape silos were added to those already under UniTree's control, and 18-track tapes were upgraded to 36-track. The primary data source for UniTree, the facility's Cray Y-MP/4-128, first doubled its processing power and then was replaced altogether by a C98/6-256 with nearly two-and-a-half times the Y-MP's combined peak gigaflops. The Convex/UniTree software was upgraded from version 1.5 to 1.7.5, and then to 1.7.6. Finally, the server itself, a Convex C3240, was upgraded to a C3830 with a second I/O bay, doubling the C3240's memory and capacity for I/O. This paper describes insights gained and reinforced with the burgeoning demands on the UniTree storage system and the significant increases in performance gained from the many upgrades.

  1. Using Cloud-based Storage Technologies for Earth Science Data

    NASA Astrophysics Data System (ADS)

    Michaelis, A.; Readey, J.; Votava, P.

    2016-12-01

    Cloud based infrastructure may offer several key benefits of scalability, built in redundancy and reduced total cost of ownership as compared with a traditional data center approach. However, most of the tools and software systems developed for NASA data repositories were not developed with a cloud based infrastructure in mind and do not fully take advantage of commonly available cloud-based technologies. Object storage services are provided through all the leading public (Amazon Web Service, Microsoft Azure, Google Cloud, etc.) and private (Open Stack) clouds, and may provide a more cost-effective means of storing large data collections online. We describe a system that utilizes object storage rather than traditional file system based storage to vend earth science data. The system described is not only cost effective, but shows superior performance for running many different analytics tasks in the cloud. To enable compatibility with existing tools and applications, we outline client libraries that are API compatible with existing libraries for HDF5 and NetCDF4. Performance of the system is demonstrated using clouds services running on Amazon Web Services.

  2. Global root zone storage capacity from satellite-based evaporation data

    NASA Astrophysics Data System (ADS)

    Wang-Erlandsson, Lan; Bastiaanssen, Wim; Gao, Hongkai; Jägermeyr, Jonas; Senay, Gabriel; van Dijk, Albert; Guerschman, Juan; Keys, Patrick; Gordon, Line; Savenije, Hubert

    2016-04-01

    We present an "earth observation-based" method for estimating root zone storage capacity - a critical, yet uncertain parameter in hydrological and land surface modelling. By assuming that vegetation optimises its root zone storage capacity to bridge critical dry periods, we were able to use state-of-the-art satellite-based evaporation data computed with independent energy balance equations to derive gridded root zone storage capacity at global scale. This approach does not require soil or vegetation information, is model independent, and is in principle scale-independent. In contrast to traditional look-up table approaches, our method captures the variability in root zone storage capacity within land cover type, including in rainforests where direct measurements of root depth otherwise are scarce. Implementing the estimated root zone storage capacity in the global hydrological model STEAM improved evaporation simulation overall, and in particular during the least evaporating months in sub-humid to humid regions with moderate to high seasonality. We find that evergreen forests are able to create a large storage to buffer for extreme droughts (with a return period of up to 60 years), in contrast to short vegetation and crops (which seem to adapt to a drought return period of about 2 years). The presented method to estimate root zone storage capacity eliminates the need for soils and rooting depth information, which could be a game-changer in global land surface modelling.

  3. 75 FR 17124 - Pressure Sensitive Plastic Tape from Italy: Notice of Continuation of Antidumping Duty Finding

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-05

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-475-059] Pressure Sensitive Plastic... antidumping duty finding on pressure sensitive plastic tape (PSP Tape) from Italy would be likely to lead to... of the margins likely to prevail were the finding to be revoked. See Pressure Sensitive Plastic Tape...

  4. County Community Development Studies. No. 2: Extensions Library on Tape, Sarasota County.

    ERIC Educational Resources Information Center

    Rozar, Luther L.; And Others

    A study was conducted in Sarasota County, Florida, to determine the feasibility of implementing a County Extension Service library on telecassette tape that could be dialed by phone callers. The system would allow office callers access to two-to-three-minute tape recordings containing information on many common problems. A survey instrument…

  5. High-speed data duplication/data distribution: An adjunct to the mass storage equation

    NASA Technical Reports Server (NTRS)

    Howard, Kevin

    1993-01-01

    The term 'mass storage' invokes the image of large on-site disk and tape farms which contain huge quantities of low- to medium-access data. Although the cost of such bulk storage is recognized, the cost of the bulk distribution of this data rarely is given much attention. Mass data distribution becomes an even more acute problem if the bulk data is part of a national or international system. If the bulk data distribution is to travel from one large data center to another large data center then fiber-optic cables or the use of satellite channels is feasible. However, if the distribution must be disseminated from a central site to a number of much smaller, and, perhaps varying sites, then cost prohibits the use of fiber-optic cable or satellite communication. Given these cost constraints much of the bulk distribution of data will continue to be disseminated via inexpensive magnetic tape using the various next day postal service options. For non-transmitted bulk data, our working hypotheses are that the desired duplication efficiency of the total bulk data should be established before selecting any particular data duplication system; and, that the data duplication algorithm should be determined before any bulk data duplication method is selected.

  6. Thermodynamic Tuning of Mg-Based Hydrogen Storage Alloys: A Review

    PubMed Central

    Zhu, Min; Lu, Yanshan; Ouyang, Liuzhang; Wang, Hui

    2013-01-01

    Mg-based hydrides are one of the most promising hydrogen storage materials because of their relatively high storage capacity, abundance, and low cost. However, slow kinetics and stable thermodynamics hinder their practical application. In contrast to the substantial progress in the enhancement of the hydrogenation/dehydrogenation kinetics, thermodynamic tuning is still a great challenge for Mg-based alloys. At present, the main strategies to alter the thermodynamics of Mg/MgH2 are alloying, nanostructuring, and changing the reaction pathway. Using these approaches, thermodynamic tuning has been achieved to some extent, but it is still far from that required for practical application. In this article, we summarize the advantages and disadvantages of these strategies. Based on the current progress, finding reversible systems with high hydrogen capacity and effectively tailored reaction enthalpy offers a promising route for tuning the thermodynamics of Mg-based hydrogen storage alloys. PMID:28788353

  7. A compensation scheme for tape-speed variation in cassette recorders.

    PubMed

    Wodicka, G R; Aguirre, A; Burns, S K; Shannon, D C

    1988-06-01

    A scheme to reduce the data corruption caused by tape-speed variation in cassette recorders used for monitoring infant apnea was developed. Low-frequency timing information is recorded on the tape, under the constraints of the frequency response of the recorder, simultaneously with the other signals. This information is extracted during playback and multiplied to a frequency suitable for data sampling, using an electronic, phase-locked loop. Analog-to-digital conversion of the data is performed at a rate proportional to the tape speed, resulting in compensation for speed variation. No direct modification of the speed-control mechanism of the recorder is required. The scheme was evaluated by comparing interval measurements of recorded timing information with and without compensation. Compensation reduced the error of the measurement by nearly an order of magnitude, which was consistent with theoretical predictions. This allows analysis of clinical value to be performed on signals recorded by systems that lack sophisticated speed-control mechanisms.

  8. New insights into designing metallacarborane based room temperature hydrogen storage media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bora, Pankaj Lochan; Singh, Abhishek K.

    Metallacarboranes are promising towards realizing room temperature hydrogen storage media because of the presence of both transition metal and carbon atoms. In metallacarborane clusters, the transition metal adsorbs hydrogen molecules and carbon can link these clusters to form metal organic framework, which can serve as a complete storage medium. Using first principles density functional calculations, we chalk out the underlying principles of designing an efficient metallacarborane based hydrogen storage media. The storage capacity of hydrogen depends upon the number of available transition metal d-orbitals, number of carbons, and dopant atoms in the cluster. These factors control the amount of chargemore » transfer from metal to the cluster, thereby affecting the number of adsorbed hydrogen molecules. This correlation between the charge transfer and storage capacity is general in nature, and can be applied to designing efficient hydrogen storage systems. Following this strategy, a search for the best metallacarborane was carried out in which Sc based monocarborane was found to be the most promising H{sub 2} sorbent material with a 9 wt.% of reversible storage at ambient pressure and temperature.« less

  9. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 4 of 4, shows footage of crew activities from flight days 8 through 12 of STS-109. The crew included: Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, Richard Linnehan, James Newman, Michael Massimino, Mission Speicalists. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476). The primary activity on flight day 8 was an EVA (extravehicular activity) by Grunsfeld and Linnehan to install a cryocooler and radiator for the NICMOS (Near Infrared Camera and Multi-Object Spectrometer) on the HST (Hubble Space Telescope). Before returning to Columbia's airlock, the astronauts, with a cloudy background, hold onto the orbiter and offer their thoughts on the significance of their mission, the HST, and spaceflight. Footage from flight day 9 includes the grappling, unbearthing, and deployment of the HST from Columbia, and the crew coordinating and videotaping Columbia's departure. Flight day 10 was a relatively inactive day, and flight day 11 includes a checkout of Columbia's aerodynamic surfaces. Columbia landed on flight day 12, which is covered by footage of the crew members speaking during reentry, and their night landing, primarily shown through the orbiter's head-up display. The video includes numerous views of the HST, as well as views of the the Galapagos Islands, Madagascar, and Southern Africa with parts of the Atlantic, Indian, and Pacific Oceans, and part of the coast of Chile. The pistol grip space tool is shown in use, and the crew answers two messages from the public, including a message to Massimino from the Fire Department of New York.

  10. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 2 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 4 and 5. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The primary activities during these days were EVAs (extravehicular activities) to replace two solar arrays on the HST (Hubble Space Telescope). Footage from flight day 4 records an EVA by Grunsfeld and Linnehan, including their exit from Columbia's payload bay airlock, their stowing of the old HST starboard rigid array on the rigid array carrier in Columbia's payload bay, their attachment of the new array on HST, the installation of a new starboard diode box, and the unfolding of the new array. The pistol grip space tool used to fasten the old array in its new location is shown in use. The video also includes several shots of the HST with Earth in the background. On flight day 5 Newman and Massimino conduct an EVA to change the port side array and diode box on HST. This EVA is very similar to the one on flight day 4, and is covered similarly in the video. A hand operated ratchet is shown in use. In addition to a repeat of the previous tasks, the astronauts change HST's reaction wheel assembly, and because they are ahead of schedule, install installation and lubricate an instrument door on the telescope. The Earth views include a view of Egypt and Israel, with the Nile River, Red Sea, and Mediterranean Sea.

  11. Programmable diagnostic devices made from paper and tape.

    PubMed

    Martinez, Andres W; Phillips, Scott T; Nie, Zhihong; Cheng, Chao-Min; Carrilho, Emanuel; Wiley, Benjamin J; Whitesides, George M

    2010-10-07

    This paper describes three-dimensional microfluidic paper-based analytical devices (3-D microPADs) that can be programmed (postfabrication) by the user to generate multiple patterns of flow through them. These devices are programmed by pressing single-use 'on' buttons, using a stylus or a ballpoint pen. Pressing a button closes a small space (gap) between two vertically aligned microfluidic channels, and allows fluids to wick from one channel to the other. These devices are simple to fabricate, and are made entirely out of paper and double-sided adhesive tape. Programmable devices expand the capabilities of microPADs and provide a simple method for controlling the movement of fluids in paper-based channels. They are the conceptual equivalent of field-programmable gate arrays (FPGAs) widely used in electronics.

  12. Modeling individual tree growth by fusing diameter tape and increment core data

    Treesearch

    Erin M. Schliep; Tracy Qi Dong; Alan E. Gelfand; Fan. Li

    2014-01-01

    Tree growth estimation is a challenging task as difficulties associated with data collection and inference often result in inaccurate estimates. Two main methods for tree growth estimation are diameter tape measurements and increment cores. The former involves repeatedly measuring tree diameters with a cloth or metal tape whose scale has been adjusted to give diameter...

  13. Does neuromuscular taping influence hand kinesiology? A pilot study on Down's Syndrome.

    PubMed

    Rigoldi, C; Galli, M; Celletti, C; Blow, D; Camerota, F; Albertini, G

    2015-01-01

    This paper is a first attempt analysis of hand and upper limb proprioception coordination induced by NeuroMuscular Taping (NMT): application in a group of 5 participants with Down syndrome. The participants underwent a drawing test with motion capture system acquisition before and after NMT application. Specific and descriptive parameters were computed and analysed in order to quantify the differences. Results showed statistical differences between pre and post treatment sessions: the 5 participants with Down syndrome evidenced more reliance on proprioceptive signals in the post treatment session during the execution of the specific writing tasks. Based on the hypothesis that modifications in proprioception should alter motor pathway mapping of the motor cortex, Neuromuscular taping may play a role in the treatment of dysgraphia and improving hand coordination following CNS impairment, even though a small treatment group was chosen for this pilot study the results lead to further discussions concerning the role of different afferent signals in a pathological context.

  14. Micrometric periodic assembly of magnetotactic bacteria and magnetic nanoparticles using audio tapes

    NASA Astrophysics Data System (ADS)

    Godoy, M.; Moreno, A. J.; Jorge, G. A.; Ferrari, H. J.; Antonel, P. S.; Mietta, J. L.; Ruiz, M.; Negri, R. M.; Pettinari, M. J.; Bekeris, V.

    2012-02-01

    We report micrometric periodic assembly of live and dead magnetotactic bacteria, Magnetospirillum magneticum AMB-1, which synthesize chains of magnetic nanoparticles inside their bodies, and of superparamagnetic Fe3O4 and ferromagnetic CoFe2O4 nanoparticles in aqueous suspensions using periodically magnetized audio tapes. The distribution of the stray magnetic field at the surface of the tapes was determined analytically and experimentally by magneto-optic imaging. Calculations showed that the magnetic field close to the tape surface was of the order of 100 mT, and the magnetic field gradient was larger than 1 T mm-1. Drops of aqueous solutions were deposited on the tapes, and bacteria and particles were trapped at locations where magnetic energy is minimized, as observed using conventional optical microscopy. Suspensions of M. magneticum AMB-1 treated with formaldehyde and kanamycin were studied, and patterns of trapped dead bacteria indicated that magnetic forces dominate over self-propelling forces in these experiments, in accordance with calculated values. The behavior of the different types of samples is discussed.

  15. Quality of life and objective outcome assessment in women with tape division after surgery for stress urinary incontinence

    PubMed Central

    Ulrich, Daniela; Bjelic-Radisic, Vesna; Höllein, Anna; Tamussino, Karl; Aigmüller, Thomas

    2017-01-01

    Background Midurethral tapes may cause long-term complications such as voiding dysfunction, groin pain, de novo urgency or mesh erosion, which necessitate a reoperation. There is a paucity of data regarding health related quality of life in patients undergoing tape removal. The aim of the study was to evaluate quality of life (QoL) and objective outcome after midurethral tape division or excision. Methods All patients who underwent a midurethral tape division for voiding difficulties, pain or therapy resistant de novo overactive bladder between 1999 and 2014 were invited for follow-up. A control group with a suburethral tape without division was established in a 1:2 ratio and matched for age, tape used and year of tape insertion. Patients completed the Kings´ Health Questionnaire (KHQ), Incontinence Outcome Questionnaire, Female Sexual Function Index Questionnaire and the Patient Global Impression of Improvement score. Results Tape division or excision was performed in 32 women. Overall, 15 (60%) of 25 women who were alive were available for clinical examination and completed the questionnaires. Tape division was performed for voiding dysfunction (n = 7), overactive bladder (n = 2), mesh extrusion (n = 3) and ongoing pain (n = 3). Median time to tape division/excision was 10 months. Three women in the tape division group had undergone reoperation for stress urinary incontinence (SUI). At a median follow-up of 11 years (IQR 9–13) subjective SUI rate was 53% (8/15 women) in the tape division group and 17% (5/30) in the control group (p = 0.016), with no significant differences in objective SUI rates between groups. With regard to quality of life, the study group had significantly worse scores in the SUI related domains role limitation, physical limitation, severity measures and social limitations (KHQ) compared to the control group. Conclusions Women needing tape division or excision have lower SUI related QoL scores compared to controls mostly because of higher

  16. Process of Making Boron-Fiber Reinforced Composite Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L. (Inventor); Cano, Roberto J. (Inventor); Johnston, Norman J. (Inventor); Marchello, Joseph M. (Inventor)

    2002-01-01

    The invention is an apparatus and method for producing a hybrid boron reinforced polymer matrix composition from powder pre-impregnated fiber tow bundles and a linear array of boron fibers. The boron fibers are applied onto the powder pre-impregnated fiber tow bundles and then are processed within a processing component having an impregnation bar assembly. After passing through variable-dimension forming nip-rollers, the powder pre-impregnated fiber tow bundles with the boron fibers become a hybrid boron reinforced polymer matrix composite tape. A driving mechanism pulls the powder pre-impregnated fiber tow bundles with boron fibers through the processing line of the apparatus and a take-up spool collects the formed hybrid boron-fiber reinforced polymer matrix composite tape.

  17. Research on Battery Energy Storage System Based on User Side

    NASA Astrophysics Data System (ADS)

    Wang, Qian; Zhang, Yichi; Yun, Zejian; Wang, Xuguang; Zhang, Dong; Bian, Di

    2018-01-01

    This paper introduces the effect of user side energy storage on the user side and the network side, a battery energy storage system for the user side is designed. The main circuit topology of the battery energy storage system based on the user side is given, the structure is mainly composed of two parts: DC-DC two-way half bridge converter and DC-AC two-way converter, a control strategy combining battery charging and discharging characteristics is proposed to decouple the grid side and the energy storage side, and the block diagram of the charging and discharging control of the energy storage system is given. The simulation results show that the battery energy storage system of the user side can not only realize reactive power compensation of low-voltage distribution network, but also improve the power quality of the users.

  18. Geophysical data base

    NASA Technical Reports Server (NTRS)

    Williamson, M. R.; Kirschner, L. R.

    1975-01-01

    A general data-management system that provides a random-access capability for large amounts of data is described. The system operates on a CDC 6400 computer using a combination of magnetic tape and disk storage. A FORTRAN subroutine package is provided to simplify the maintenance and use of the data.

  19. Conformity of modified O-ring test and maximal pinch strength for cross tape application direction.

    PubMed

    Lee, Jung-Hoon; Choi, Hyun-Su

    2018-06-01

    Although cross tape has recently been used by clinicians for various musculoskeletal conditions, scientific studies on the direction of cross tape application are lacking. The present study aimed to investigate whether the direction of cross tape application affected the outcomes of the modified O-ring test and maximal pinch strength using a pinch gauge and the conformity between these 2 tests when cross tape was applied to the forearm muscles of individuals with no upper extremity pain and no restriction of joint range of motion.This study used a single-blinding crossover design. The subjects comprised 39 adults (16 men and 23 women). Cross tape was applied to the dominant hand so that the 4 rows were at an angle of 45° to the right or left of the direction of the flexor digitorum superficialis muscle fibers, and then the subjects underwent a modified O-ring test and a test of maximal pinch strength using a pinch gauge. Both tests were performed in both directions, and the order of the directions and tests was randomized. SPSS 18.0 was used for statistical analysis. Cohen's kappa coefficient was used to analyze the conformity of the results from the 2 tests. The statistical significance level was P < .05. A positive response in the modified O-ring test and maximal pinch strength were both affected by cross tape direction. The modified O-ring test and maximal pinch strength using pinch gauge results were in agreement (P < .00), and the kappa coefficient was significant at 1.00. The direction of cross tape application that produced a positive response in the modified O-ring test also produced greater maximal pinch strength. Thus, we propose that when applying cross tape to muscles, the direction of the 4 lines of the cross tape should be 45° relative to the direction of the muscle fibers, toward the side that produces a positive response in the modified O-ring test or produces the greatest maximal pinch strength using a pinch gauge.

  20. Surgical management of stress urinary incontinence in women: safety, effectiveness and cost-utility of trans-obturator tape (TOT) versus tension-free vaginal tape (TVT) five years after a randomized surgical trial

    PubMed Central

    2011-01-01

    Background We recently completed a randomized clinical trial of two minimally invasive surgical procedures for stress urinary incontinence, the retropubic tension-free vaginal tape (TVT) versus the trans-obturator tape (TOT) procedure. At one year postoperatively, we were concerned to find that a significant number of women had tape that was palpable when a vaginal examination was undertaken. Because the risk factors for adverse outcomes of tape surgery are not clearly understood, we are unable to say whether palpable tapes will lead to vaginal erosions or whether they merge into vaginal tissue. We do not know whether patients go on to have further adverse consequences of surgery, leading to additional cost to patients and healthcare system. Our current study is a 5 year follow-up of the women who took part in our original trial. Methods/Design All 199 women who participated in our original trial will be contacted and invited to take part in the follow-up study. Consenting women will attend a clinic visit where they will have a physical examination to identify vaginal erosion or other serious adverse outcomes of surgery, undertake a standardized pad test for urinary incontinence, and complete several health-related quality of life questionnaires (15D, UDI-6, IIQ-7). Analyses will compare the outcomes for women in the TOT versus TVT groups. The cost-effectiveness of TOT versus TVT over the 5 years after surgery, will be assessed with the use of disease-specific health service administrative data and an objective health outcome measure. A cost-utility analysis may also be undertaken, based on economic modeling, data from the clinical trial and inputs obtained from published literature. Discussion This study is needed now, because TOT and TVT are among the most frequently conducted surgical procedures for stress urinary incontinence in Canada. Because stress urinary incontinence is so common, the impact of selecting an approach that causes more adverse events, or is