Sample records for tapio ilma grigaliunaite

  1. Comparison of blind intubation through the I-gel and ILMA Fastrach by nurses during cardiopulmonary resuscitation: a manikin study.

    PubMed

    Melissopoulou, Theodora; Stroumpoulis, Konstantinos; Sampanis, Michail A; Vrachnis, Nikolaos; Papadopoulos, Georgios; Chalkias, Athanasios; Xanthos, Theodoros

    2014-01-01

    To investigate whether nursing staff can successfully use the I-gel and the intubating laryngeal mask Fastrach (ILMA) during cardiopulmonary resuscitation. Although tracheal intubation is considered to be the optimal method for securing the airway during cardiopulmonary resuscitation, laryngoscopy requires a high level of skill. Forty five nurses inserted the I-gel and the ILMA in a manikin, with continuous and without chest compressions. Mean intubation times for the ILMA and I-gel without chest compressions were 20.60 ± 3.27 and 18.40 ± 3.26 s, respectively (p < 0.0005). ILMA proved more successful than the I-gel regardless of compressions. Continuation of compressions caused a prolongation in intubation times for both the I-gel (p < 0.0005) and the ILMA (p < 0.0005). In this mannequin study, nursing staff can successfully intubate using the I-gel and the ILMA as conduits with comparable success rates, regardless of whether chest compressions are interrupted or not. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Orbitrap-based mass analyser for in-situ characterization of asteroids: ILMA, Ion Laser Mass Analyser

    NASA Astrophysics Data System (ADS)

    Briois, C.; Cotti, H.; Thirkell, L.; Space Orbitrap Consortium[K. Aradj, French; Bouabdellah, A.; Boukrara, A.; Carrasco, N.; Chalumeau, G.; Chapelon, O.; Colin, F.; Coll, P.; Engrand, C.; Grand, N.; Kukui, A.; Lebreton, J.-P.; Pennanech, C.; Szopa, C.; Thissen, R.; Vuitton, V.; Zapf], P.; Makarov, A.

    2014-07-01

    Since about a decade the boundaries between comets and carbonaceous asteroids are fading [1,2]. No doubt that the Rosetta mission should bring a new wealth of data on the composition of comets. But as promising as it may look, the mass resolving power of the mass spectrometers onboard (so far the best on a space mission) will only be able to partially account for the diversity of chemical structures present. ILMA (Ion-Laser Mass Analyser) is a new generation high mass resolution LDI-MS (Laser Desorption-Ionization Mass Spectrometer) instrument concept using the Orbitrap technique, which has been developed in the frame of the two Marco Polo & Marco Polo-R proposals to the ESA Cosmic Vision program. Flagged by ESA as an instrument concept of interest for the mission in 2012, it has been under study for a few years in the frame of a Research and Technology (R&T) development programme between 5 French laboratories (LPC2E, IPAG, LATMOS, LISA, CSNSM) [3,4], partly funded by the French Space Agency (CNES). The work is undertaken in close collaboration with the Thermo Fisher Scientific Company, which commercialises Orbitrap-based laboratory instruments. The R&T activities are currently concentrating on the core elements of the Orbitrap analyser that are required to reach a sufficient maturity level for allowing design studies of future space instruments. A prototype is under development at LPC2E and a mass resolution (m/Δm FWHM) of 100,000 as been obtained at m/z = 150 for a background pressure of 10^{-8} mbar. ILMA would be a key instrument to measure the molecular, elemental and isotopic composition of objects such as carbonaceous asteroids, comets, or other bodies devoid of atmosphere such as the surface of an icy satellite, the Moon, or Mercury.

  3. An intravascular loopless monopole antenna for vessel wall MR imaging at 3.0 T.

    PubMed

    Yuan, Hongyang; Lv, Xing; Ma, Xiaohai; Zhang, Rui; Fu, Youyi; Yang, Xuedong; Wang, Xiaoying; Zhang, Zhaoqi; Zhang, Jue; Fang, Jing

    2013-01-01

    The purpose of this study was to develop a novel intravascular loopless monopole antenna (ILMA) design specifically for imaging of small vessel walls. The ILMA consisted of an unshielded, low-friction guide wire and a tuning/matching box. The material of the guide wire was nitinol and it was coated with polyurethane. Because the guide wire was unshielded, it could be made thinner than the coaxial cable-based loopless intravascular antenna design. The material of the box was aluminum. In this study, the diameter of the guide wire was 0.5 mm and the length was 58.7 mm. The ILMA was used as a receiving antenna and body coil for transmission. To verify the feasibility of the ILMA, in vitro and in vivo experiments were performed on a 3.0-T magnetic resonance (MR) scanner. In vitro tests using the ILMA indicated that the proposed design could be used to image target vessel walls with a spatial resolution of 313 μm at the frequency coding direction and more than 100 mm of longitudinal coverage. In vivo tests demonstrated that the images showed the vessel walls clearly by using the ILMA and also indicated that the ILMA could be used for small vessels. The proposed antenna may therefore be utilized to promote MR-based diagnoses and therapeutic solutions for cardiovascular atherosclerotic diseases. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Placement of Intubating Laryngeal Mask Airway Is Easier than Placement of Laryngeal Tube during Manual In-Line Stabilisation of The Neck

    PubMed Central

    Komatsu, R.; Nagata, O.; Kamata, K.; Yamagata, K.; Sessler, D.I.; Ozaki, M.

    2005-01-01

    Summary We compared the usefulness of the laryngeal tube (LT) with the intubating laryngeal mask airway (ILMA) in 51 patients whose necks were stabilised by manual in-line traction. After induction of anaesthesia and neuromuscular block, the LT and ILMA were inserted consecutively in a randomised, crossover design. During pressure-controlled ventilation (20 cmH2O inspiratory pressure), we measured insertion attempts, time to establish positive-pressure ventilation, tidal volume, gastric insufflation, and minimum airway pressure at which gas leaked around the cuff. Data were compared using Wilcoxon signed-rank tests; P<0.05 was considered significant. Insertion was more difficult with the LT (successful at first attempt in 16 patients) than with the ILMA (successful at first attempt in 42 patients, P<0.0001). Time required for insertion was longer for the LT (28 [23–35] sec, median [interquartile range]) than the ILMA (20 [15–25] sec, P=0.0009). Tidal volume was less for the LT (440 [290–670] ml) than the ILMA. (630 [440–750] ml, P=0.013). Minimum airway pressure at which gas leak occurred and incidence of gastric insufflation were similar with two devices. In patients whose necks were stabilised with manual in-line traction, insertion of the ILMA was easier and quicker than insertion of the LT and tidal volume was greater with the ILMA than the LT. PMID:15644005

  5. The Intubating Laryngeal Mask Airway Allows Tracheal Intubation When the Cervical Spine Is Immobilized by a Rigid Collar

    PubMed Central

    Komatsu, Ryu; Nagata, Osamu; Kamata, Kotoe; Yamagata, Katsuyuki; Sessler, Daniel I.; Ozaki, Makoto

    2005-01-01

    Summary An intubating laryngeal mask airway (ILMA) facilitates tracheal intubation with the neck in neutral position, which is similar to the neck position maintained by a rigid cervical collar. However, a cervical collar virtually obliterates neck movement, even the small movements that normally facilitate airway insertion. We therefore tested the hypothesis that the ILMA facilitates tracheal intubation even in patients wearing a rigid cervical collar. In 50 cervical spine surgery patients with a rigid Philadelphia collar in place and 50 general surgery patients under general anaesthesia, we performed blind tracheal intubation via an ILMA. The time required for intubation, intubation success rate, and numbers and type of adjusting manoeuvres employed were recorded. Inter-incisor distance was significantly smaller (4.1 [0.8] cm vs. 4.6 [0.7] cm, mean [SD], P<0.01) and Mallampati scores were significantly greater (P<0.001) in the collared patients. ILMA insertion took longer (30 [25] vs. 22 [6] seconds), more patients required 2 insertion attempts (15 vs. 3; P<0.005), and ventilation adequacy with ILMA was worse (P<0.05) in collared patients. However, there were no significant differences between the collared and control patients in terms of total time required for intubation (60 [41] vs. 50 [30] seconds), number of intubation attempts, overall intubation success rate (96 vs. 98%), or the incidence of intubation complications. Blind intubation through an ILMA is thus a reasonable strategy for controlling the airway in patients who are immobilized with a rigid cervical collar, especially when urgency precludes a fiberoptic approach. PMID:15321932

  6. Ionic liquid-based microwave-assisted extraction of essential oil and biphenyl cyclooctene lignans from Schisandra chinensis Baill fruits.

    PubMed

    Ma, Chun-hui; Liu, Ting-ting; Yang, Lei; Zu, Yuan-gang; Chen, Xiaoqiang; Zhang, Lin; Zhang, Ying; Zhao, Chunjian

    2011-12-02

    Ionic liquid-based microwave-assisted extraction (ILMAE) has been successfully applied in extracting essential oil and four kinds of biphenyl cyclooctene lignans from Schisandra chinensis Baill. 0.25 M 1-lauryl-3-methylimidazolium bromide ionic liquid is selected as solvent. The optimum parameters of dealing with 25.0 g sample are 385 W irradiation power, 40 min microwave extraction time and 1:12 solid-liquid ratio. The yields of essential oil and lignans are 12.12±0.37 ml/kg and 250.2±38.2 mg/kg under the optimum conditions. The composition of the essential oil extracted by hydro-distillation, steam-distillation and ILMAE is analyzed by GC-MS. With ILMAE method, the energy consumption time has not only been shortened to 40 min (hydro-distillation 3.0 h for extracting essential oil and reflux extraction 4.0 h for extracting lignans, respectively), but also the extraction efficiency has been improved (extraction of lignans and distillation of essential oil at the same time) and reduces the environmental pollution. S. chinensis materials treated by different methods are observed by scanning electronic microscopy. Micrographs provide more evidence to prove that ILMAE is a better and faster method. The experimental results also indicate that ILMAE is a simple and efficient technique for sample preparation. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: a manikin study.

    PubMed

    Michalek, P; Donaldson, W; Graham, C; Hinds, J D

    2010-01-01

    Insertion of a supraglottic airway and tracheal intubation through it may be indicated in resuscitation scenarios where conventional laryngoscopy fails. Various supraglottic devices have been used as conduits for tracheal intubation, including the intubating laryngeal mask airway (ILMA), the Ctrach laryngeal mask and the I-gel supraglottic airway. A prospective study with 25 participants evaluated the success rate of blind intubation (using a gum-elastic bougie, an Aintree intubating catheter (AIC) and designated tracheal tube) and fibrescope-guided tracheal intubation (through the intubating laryngeal mask airway and the I-gel supraglottic airway) on three different airway manikins. Twenty-five anaesthetists performed three intubations with each method on each of three manikins. The success rate of the fibrescope-guided technique was significantly higher than blind attempts (P<0.0001) with both devices. For fibreoptic techniques, there was no difference found between the ILMA and I-gel (P>0.05). All blind techniques were significantly more successful in the ILMA group compared to the I-gel (P<0.0001 for bougie, Aintree catheter and tracheal tube, respectively). The results of this study show that, in manikins, fibreoptic intubation through both ILMA and I-gel is a highly successful technique. Blind intubation through the I-gel showed a low success rate and should not be attempted. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  8. Application of Ionic Liquids in the Microwave-Assisted Extraction of Proanthocyanidins from Larix gmelini Bark

    PubMed Central

    Yang, Lei; Sun, Xiaowei; Yang, Fengjian; Zhao, Chunjian; Zhang, Lin; Zu, Yuangang

    2012-01-01

    Ionic liquid based, microwave-assisted extraction (ILMAE) was successfully applied to the extraction of proanthocyanidins from Larix gmelini bark. In this work, in order to evaluate the performance of ionic liquids in the microwave-assisted extraction process, a series of 1-alkyl-3-methylimidazolium ionic liquids with different cations and anions were evaluated for extraction yield, and 1-butyl-3-methylimidazolium bromide was selected as the optimal solvent. In addition, the ILMAE procedure for the proanthocyanidins was optimized and compared with other conventional extraction techniques. Under the optimized conditions, satisfactory extraction yield of the proanthocyanidins was obtained. Relative to other methods, the proposed approach provided higher extraction yield and lower energy consumption. The Larix gmelini bark samples before and after extraction were analyzed by Thermal gravimetric analysis, Fourier-transform infrared spectroscopy and characterized by scanning electron microscopy. The results showed that the ILMAE method is a simple and efficient technique for sample preparation. PMID:22606036

  9. Comparison of 4 supraglotttic devices used by paramedics during simulated CPR : a randomized controlled crossover trial.

    PubMed

    Szarpak, Łukasz; Kurowski, Andrzej; Truszewski, Zenon; Robak, Oliver; Frass, Michael

    2015-08-01

    Ensuring an open airway during cardiopulmonary resuscitation is fundamental. The aim of this study was to determine the success rate of blind intubation during simulated cardiopulmonary resuscitation by untrained personnel. Four devices were compared in a simulated resuscitation scenario: ILMA (Intavent Direct Ltd, Buckinghamshire, United Kingdom), Cobra PLA (Engineered Medical Systems Inc, Indianapolis, IN), Supraglottic Airway Laryngopharyngeal Tube (SALT) (ECOLAB, St. Paul, MN), and Air-Q (Mercury Medical, Clearwater, FL). A group of 210 paramedics intubated a manikin with continuous chest compressions. The mean times to intubation were 40.46 ± 4.64, 33.96 ± 6.23, 17.2 ± 4.63, and 49.23 ± 13.19 seconds (SALT vs ILMA, Cobra PLA, and Air-Q; P < .05). The success ratios of blind intubation for the devices were 86.7%, 85.7%, 100%, and 71.4% (SALT vs ILMA, Cobra PLA, and Air-Q; P < .05). The study showed that the most efficient device with the shortest blind intubation time was the SALT device. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Conventional tracheal tubes for intubation through the intubating laryngeal mask airway.

    PubMed

    Kundra, Pankaj; Sujata, N; Ravishankar, M

    2005-01-01

    The laryngeal mask airway (LMA)-Fastrach silicone wire-reinforced tracheal tube (FTST) was specially designed for tracheal intubation through the intubating LMA (ILMA). However, conventional tracheal tubes have been successfully used to accomplish tracheal intubation. We designed this study to evaluate the success rate of blind tracheal intubation through the ILMA by using the FTST, the Rusch polyvinyl chloride tube (PVCT), and the Rusch latex armored tube (LAT). One-hundred-fifty healthy adults of ASA physical status I and II who were undergoing elective surgery under general anesthesia were randomly allocated into three groups. FTST (n=50), prewarmed PVCT (n=50), and LAT (n=50) were used for tracheal intubation. Ease of tracheal intubation was assessed by the time taken, the number of attempts, and the number of maneuvers required for success. In addition, numbers of failed intubation attempts and times taken for ILMA removal were also recorded. After surgery, the incidence of trauma, sore throat, and hoarseness was noted. Significantly more frequent success in tracheal intubation was achieved with the PVCT and FTST (96%) compared with the LAT (82%) (P <0.05). Tracheal intubation on the first attempt was similar with the PVCT and FTST (86%) and was significantly more frequent than with the LAT (52%) (P <0.05). Esophageal placement was significantly more frequent with the LAT (29.7%) when compared with the PVCT and FTST (1.8% and 7.4%, respectively) (P <0.05). The authors conclude that a prewarmed PVCT can be used as successfully as the FTST for blind tracheal intubation through the ILMA, whereas the LAT is associated with more frequent failure and esophageal intubation.

  11. Development of Sub-optimal Airway Protocols for the International Space Station (ISS) by the Medical Operation Support Team (MOST)

    NASA Technical Reports Server (NTRS)

    Polk, James D.; Parazynski, Scott; Kelly, Scott; Hurst, Victor, IV; Doerr, Harold K.

    2007-01-01

    Airway management techniques are necessary to establish and maintain a patent airway while treating a patient undergoing respiratory distress. There are situations where such settings are suboptimal, thus causing the caregiver to adapt to these suboptimal conditions. Such occurrences are no exception aboard the International Space Station (ISS). As a result, the NASA flight surgeon (FS) and NASA astronaut cohorts must be ready to adapt their optimal airway management techniques for suboptimal situations. Based on previous work conducted by the Medical Operation Support Team (MOST) and other investigators, the MOST had members of both the FS and astronaut cohorts evaluate two oral airway insertion techniques for the Intubating Laryngeal Mask Airway (ILMA) to determine whether either technique is sufficient to perform in suboptimal conditions within a microgravity environment. Methods All experiments were conducted in a simulated microgravity environment provided by parabolic flight aboard DC-9 aircraft. Each participant acted as a caregiver and was directed to attempt both suboptimal ILMA insertion techniques following a preflight instruction session on the day of the flight and a demonstration of the technique by an anesthesiologist physician in the simulated microgravity environment aboard the aircraft. Results Fourteen participants conducted 46 trials of the suboptimal ILMA insertion techniques. Overall, 43 of 46 trials (94%) conducted were properly performed based on criteria developed by the MOST and other investigators. Discussion The study demonstrated the use of airway management techniques in suboptimal conditions relating to space flight. Use of these techniques will provide a crew with options for using the ILMA to manage airway issues aboard the ISS. Although it is understood that the optimal method for patient care during space flight is to have both patient and caregiver restrained, these techniques provide a needed backup should conditions not present

  12. The intubating laryngeal mask. II: A preliminary clinical report of a new means of intubating the trachea.

    PubMed

    Brain, A I; Verghese, C; Addy, E V; Kapila, A; Brimacombe, J

    1997-12-01

    We have assessed the efficacy of a new laryngeal mask prototype, the intubating laryngeal mask airway (ILMA), as a ventilatory device and blind intubation guide. The ILMA consists of an anatomically curved, short, wide bore, stainless steel tube sheathed in silicone which is bonded to a laryngeal mask and a guiding handle. It has a single moveable aperture bar, a guiding ramp and can accommodate an 8 mm tracheal tube (TT). After induction of anaesthesia with propofol 2.5 mg kg-1 and fentanyl 2.5 micrograms kg-1, the device was inserted successfully at the first attempt in all 150 (100%) patients and adequate ventilation achieved in all, with minor adjustments required in four patients. Placement did not require movement of the head and neck or insertion of the fingers in the patient's mouth. Blind tracheal intubation using a straight silicone cuffed TT was attempted after administration of atracurium 0.5 mg kg-1. If resistance was felt during intubation, a sequence of adjusting manoeuvres was used based on the depth at which resistance occurred. Tracheal intubation was possible in 149 of 150 (99.3%) patients. In 75 (50%) patients no resistance was encountered and the trachea was intubated at the first attempt, 28 (19%) patients required one adjusting manoeuvre and 46 (31%) patients required 2-4 adjusting manoeuvres before intubation was successful. There were 13 patients with potential or known airway problems. The lungs of all of these patients were ventilated easily and the trachea intubated using the ILMA. In 10 of 13 (77%) of these patients, no resistance was encountered and the trachea was intubated at the first attempt; three of 13 (23%) patients required one adjusting manoeuvre. Tracheal intubation required significantly fewer adjusting manoeuvres in patients with a predicted or known difficult airway (P < 0.05). We conclude that the ILMA appeared on initial assessment to be an effective ventilatory device and intubation guide for routine and difficult

  13. The Intubating Laryngeal Mask Airway Facilitates Tracheal Intubation in the Lateral Position

    PubMed Central

    Komatsu, Ryu; Nagata, Osamu; Sessler, Daniel I.; Ozaki, Makoto

    2005-01-01

    Although the difficulty of tracheal intubation in the lateral position has not been systematically evaluated, airway loss during surgery in a laterally positioned patient may have hazardous consequences. We explored whether the intubating laryngeal mask airway (ILMA) facilitates tracheal intubation in patients with normal airway anatomy, i.e., Mallampati grade ≤ 3 and thyromental distance ≥ 5 cm, positioned in the lateral position. And we evaluated whether this technique can be used as a rescue when the airway is lost mid-case in laterally positioned patients with respect to success rate and intubation time. Anesthesia was induced with propofol, fentanyl, and vecuronium in 50 patients undergoing spine surgery for lumbar disk herniation (Lateral) and 50 undergoing other surgical procedures (Supine). Patients having disk surgery (Lateral) were positioned on their right or left sides before induction of general anesthesia, and intubation was performed in that position. Patients in control group (Supine) were anesthetized in supine position, and intubation was performed in that position. Intubation was performed blindly via an ILMA in both groups. The time required for intubation and number and types of adjusting maneuvers employed were recorded. Data were compared by Mann-Whitney U, Fisher’s exact, chi-square, or unpaired t-tests, as appropriate. Data presented as mean (SD). Demographic and airway measures were similar in the two groups, except for mouth opening which was slightly wider in patients in the lateral position: 5.1 (0.9) vs. 4.6 (0.7) cm. The time required for intubation was similar in each group (≈25 s), as was intubation success (96%). We conclude that blind intubation via an ILMA offers a frequent success rate and a clinically acceptable intubation time (< one min) even in the lateral position. Summary Blind intubation via the intubating laryngeal mask airway (ILMA) offers a high success rate and a clinically acceptable intubation time even in

  14. Ionic liquid-based microwave-assisted extraction for the determination of flavonoid glycosides in pigeon pea leaves by high-performance liquid chromatography-diode array detector with pentafluorophenyl column.

    PubMed

    Wei, Wei; Fu, Yu-jie; Zu, Yuan-gang; Wang, Wei; Luo, Meng; Zhao, Chun-jian; Li, Chun-ying; Zhang, Lin; Wei, Zuo-fu

    2012-11-01

    In this study, an ionic liquid-based microwave-assisted extraction (ILMAE) followed by high-performance liquid chromatography-diode array detector with a pentafluorophenyl column for the extraction and quantification of eight flavonoid glycosides in pigeon pea leaves is described. Compared with conventional extraction methods, ILMAE is a more effective and environment friendly method for the extraction of nature compounds from herbal plants. Nine different types of ionic liquids with different cations and anions were investigated. The results suggested that varying the anion and cation had significant effects on the extraction of flavonoid glycosides, and 1.0 M 1-butyl-3-methylimidazolium bromide ([C4MIM]Br) solution was selected as solvent. In addition, the extraction procedures were also optimized using a series of single-factor experiments. The optimum parameters were obtained as follows: extraction temperature 60°C, liquid-solid ratio 20:1 mL/g and extraction time 13 min. Moreover, an HPLC method using pentafluorophenyl column was established and validated. Good linearity was observed with the regression coefficients (r(2)) more than 0.999. The limit of detection (LODs) (S/N = 3) and limit of quantification (LOQs) (S/N = 10) for the components were less than 0.41 and 1.47 μg/mL, respectively. The inter- and intraday precisions that were used to evaluate the reproducibility and relative standard deviation (RSD) values were less than 4.57%. The recoveries were between 97.26 and 102.69%. The method was successfully used for the analysis of samples of pigeon pea leaves. In conclusion, the developed ILMAE-HPLC-diode array detector using pentafluorophenyl column method can be applied for quality control of pigeon pea leaves and related medicinal products. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Tactical Combat Casualty Care 2007: Evolving Concepts and Battlefield Experience

    DTIC Science & Technology

    2007-11-01

    airway obstruction: chin lift or jaw thrust, nasopharyngeal airway, place casualty in recovery position Surgical cricothyroidotomy (with lidocaine ...laryngeal mask airway /ILMA or Combitube or endotracheal intubation or surgical cricothyroidotomy (with lidocaine if conscious) Spinal immobilization is...surgical cricothyroidotomy (with lidocaine If conscious) 3. Breathing Consider tension pneumothorax and decompress with needle thoracostomy if

  16. Ionic liquid-based microwave-assisted extraction of flavonoids from Bauhinia championii (Benth.) Benth.

    PubMed

    Xu, Wei; Chu, Kedan; Li, Huang; Zhang, Yuqin; Zheng, Haiyin; Chen, Ruilan; Chen, Lidian

    2012-12-03

    An ionic liquids (IL)-based microwave-assisted approach for extraction and determination of flavonoids from Bauhinia championii (Benth.) Benth. was proposed for the first time. Several ILs with different cations and anions and the microwave-assisted extraction (MAE) conditions, including sample particle size, extraction time and liquid-solid ratio, were investigated. Two M 1-butyl-3-methylimidazolium bromide ([bmim] Br) solution with 0.80 M HCl was selected as the optimal solvent. Meanwhile the optimized conditions a ratio of liquid to material of 30:1, and the extraction for 10 min at 70 °C. Compared with conventional heat-reflux extraction (CHRE) and the regular MAE, IL-MAE exhibited a higher extraction yield and shorter extraction time (from 1.5 h to 10 min). The optimized extraction samples were analysed by LC-MS/MS. IL extracts of Bauhinia championii (Benth.)Benth consisted mainly of flavonoids, among which myricetin, quercetin and kaempferol, β-sitosterol, triacontane and hexacontane were identified. The study indicated that IL-MAE was an efficient and rapid method with simple sample preparation. LC-MS/MS was also used to determine the chemical composition of the ethyl acetate/MAE extract of Bauhinia championii (Benth.) Benth, and it maybe become a rapid method to determine the composition of new plant extracts.

  17. Clinical Space Medicine Products as Developed by the Medical Operations Support Team (MOST)

    NASA Technical Reports Server (NTRS)

    Polk, James D.; Doerr, Harold K.; Hurst, Victor W., IV; Schmid, Josef

    2007-01-01

    Medical Operations Support Team (MOST) is introducing/integrating teaching practices associated with high fidelity human patient simulation into the NASA culture, in particular, into medical training sessions and medical procedure evaluations. Current/Future Products iclude: a) Development of Sub-optimal Airway Protocols for the International Space Station (ISS) using the ILMA; b) Clinical Core Competency Training for NASA Flight Surgeons (FS); c) Post-Soyuz Landing Clinical Training for NASA FS; d) Experimental Integrated Training for Astronaut Crew Medical Officers and NASA FS; and e) Private Clinical Refresher Training.

  18. Tracheal injury as a sequence of multiple attempts of endotracheal intubation in the course of a preclinical cardiopulmonary resuscitation.

    PubMed

    Jaeger, K; Ruschulte, H; Osthaus, A; Scheinichen, D; Heine, J

    2000-01-01

    Management of the difficult airway requires an appropriate approach based on personal clinical experiences. For every physician involved in rescue and emergency medicine, it is important to know the difficult airway algorithm and be familiar with alternative techniques of managing the difficult airway. We report a case of tracheal injury caused by multiple attempts at intubating the trachea. Based on current knowledge, apart from surgical equipment for cricothyroidotomy the laryngeal mask airway (LMA) and the Combitube (ETC) should be available on any ambulance vehicle staffed by an emergency physician. In future, blind intubation through the intubating laryngeal mask airway (ILMA) could offer a new opportunity.

  19. The Quantum and Fluid Mechanics of Global Warming

    NASA Astrophysics Data System (ADS)

    Marston, Brad

    2008-03-01

    Quantum physics and fluid mechanics are the foundation of any understanding of the Earth's climate. In this talk I invoke three well-known aspects of quantum mechanics to explore what will happen as the concentrations of greenhouse gases such as carbon dioxide continue to increase. Fluid dynamical models of the Earth's atmosphere, demonstrated here in live simulations, yield further insight into past, present, and future climates. Statistics of geophysical flows can, however, be ascertained directly without recourse to numerical simulation, using concepts borrowed from nonequilibrium statistical mechanicsootnotetextJ. B. Marston, E. Conover, and Tapio Schneider, ``Statistics of an Unstable Barotropic Jet from a Cumulant Expansion,'' arXiv:0705.0011, J. Atmos. Sci. (in press).. I discuss several other ways that theoretical physics may be able to contribute to a deeper understanding of climate changeootnotetextJ. Carlson, J. Harte, G. Falkovich, J. B. Marston, and R. Pierrehumbert, ``Physics of Climate Change'' 2008 Program of the Kavli Institute for Theoretical Physics..

  20. Optimization of Ionic Liquid-Assisted Extraction of Biflavonoids from Selaginella doederleinii and Evaluation of Its Antioxidant and Antitumor Activity.

    PubMed

    Li, Dan; Qian, Yan; Tian, Yu-Jia; Yuan, Shi-Meng; Wei, Wei; Wang, Gang

    2017-04-07

    As new green solvents, ionic liquids (ILs) have been generally applied in the extraction and separation of natural product. In this study, microwave assisted extraction based on IL (IL-MAE) was firstly employed to extract total biflavonoids from Selaginella doederleinii . Based on single-factor experiment, microwave power (300-700 W), extract time (30-50 min) and extract temperature (40-60 °C) on total bioflavonoids and antioxidant activities of the extracts were further investigated by a Box-Behnken design of response surface methodology (RSM) selecting total bioflavonoids yields and IC 50 of radical scavenging as index. Besides antioxidant activity of the extract was evaluated by a 2,2-diphenyl-1-picrylhydarzyl (DPPH) and 2,2'-azinobis-(3-ethylbenzthiazoline-6-sulphonate (ABTS) radical scavenging assay, ferric reducing power assay and chelation of ferrous ions assay, and then anticaner activity was also researched against A549 cell line and 7721 cell line. The results illustrated that three factors and their interactions could be well suited for second-order polynomial models ( p < 0.05). Through process parameters, optimization of the extract (460 W, 40 min, and 45 °C) and detection of bioactivity, the yield of total bioflavonoids was 16.83 mg/g and IC 50 value was 56.24 μg/mL, respectively, indicating the extract has better anti-oxidation effect and antitumor activity. Furthermore, IL-MAE was the most efficient extracting method compared with MAE and Soxhlet extraction, which could improve extraction efficiency in a shorter time and at a lower temperature. In general, ILs-MAE was first adopted to establish a novel and green extraction process on the yields of total biflavonoids from S. doederleinii . In addition, the extract of containing biflavones showed potent antioxidant and anticancer capacity as a utilized valuable bioactive source for natural medicine.

  1. Empirical Research on Decoupling Relationship between Energy-Related Carbon Emission and Economic Growth in Guangdong Province Based on Extended Kaya Identity

    PubMed Central

    Wang, Wenxiu; Huang, Ningsheng; Zhao, Daiqing

    2014-01-01

    The decoupling elasticity decomposition quantitative model of energy-related carbon emission in Guangdong is established based on the extended Kaya identity and Tapio decoupling model for the first time, to explore the decoupling relationship and its internal mechanism between energy-related carbon emission and economic growth in Guangdong. Main results are as follows. (1) Total production energy-related carbon emissions in Guangdong increase from 4128 × 104 tC in 1995 to 14396 × 104 tC in 2011. Decoupling elasticity values of energy-related carbon emission and economic growth increase from 0.53 in 1996 to 0.85 in 2011, and its decoupling state turns from weak decoupling in 1996–2004 to expansive coupling in 2005–2011. (2) Land economic output and energy intensity are the first inhibiting factor and the first promoting factor to energy-related carbon emission decoupling from economic growth, respectively. The development speeds of land urbanization and population urbanization, especially land urbanization, play decisive roles in the change of total decoupling elasticity values. (3) Guangdong can realize decoupling of energy-related carbon emission from economic growth effectively by adjusting the energy mix and industrial structure, coordinating the development speed of land urbanization and population urbanization effectively, and strengthening the construction of carbon sink. PMID:24782666

  2. Empirical research on decoupling relationship between energy-related carbon emission and economic growth in Guangdong province based on extended Kaya identity.

    PubMed

    Wang, Wenxiu; Kuang, Yaoqiu; Huang, Ningsheng; Zhao, Daiqing

    2014-01-01

    The decoupling elasticity decomposition quantitative model of energy-related carbon emission in Guangdong is established based on the extended Kaya identity and Tapio decoupling model for the first time, to explore the decoupling relationship and its internal mechanism between energy-related carbon emission and economic growth in Guangdong. Main results are as follows. (1) Total production energy-related carbon emissions in Guangdong increase from 4128 × 10⁴ tC in 1995 to 14396 × 10⁴ tC in 2011. Decoupling elasticity values of energy-related carbon emission and economic growth increase from 0.53 in 1996 to 0.85 in 2011, and its decoupling state turns from weak decoupling in 1996-2004 to expansive coupling in 2005-2011. (2) Land economic output and energy intensity are the first inhibiting factor and the first promoting factor to energy-related carbon emission decoupling from economic growth, respectively. The development speeds of land urbanization and population urbanization, especially land urbanization, play decisive roles in the change of total decoupling elasticity values. (3) Guangdong can realize decoupling of energy-related carbon emission from economic growth effectively by adjusting the energy mix and industrial structure, coordinating the development speed of land urbanization and population urbanization effectively, and strengthening the construction of carbon sink.

  3. Ionic liquids based microwave-assisted extraction of lichen compounds with quantitative spectrophotodensitometry analysis.

    PubMed

    Bonny, Sarah; Paquin, Ludovic; Carrié, Daniel; Boustie, Joël; Tomasi, Sophie

    2011-11-30

    Ionic liquids based extraction method has been applied to the effective extraction of norstictic acid, a common depsidone isolated from Pertusaria pseudocorallina, a crustose lichen. Five 1-alkyl-3-methylimidazolium ionic liquids (ILs) differing in composition of alkyl chain and anion were investigated for extraction efficiency. The extraction amount of norstictic acid was determined after recovery on HPTLC with a spectrophotodensitometer. The proposed approaches (IL-MAE and IL-heat extraction (IL-HE)) have been evaluated in comparison with usual solvents such as tetrahydrofuran in heat-reflux extraction and microwave-assisted extraction (MAE). The results indicated that both the characteristics of the alkyl chain and anion influenced the extraction of polyphenolic compounds. The sulfate-based ILs [C(1)mim][MSO(4)] and [C(2)mim][ESO(4)] presented the best extraction efficiency of norstictic acid. The reduction of the extraction times between HE and MAE (2 h-5 min) and a non-negligible ratio of norstictic acid in total extract (28%) supports the suitability of the proposed method. This approach was successfully applied to obtain additional compounds from other crustose lichens (Pertusaria amara and Ochrolechia parella). Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Towards a Global High Resolution Peatland Map in 2020

    NASA Astrophysics Data System (ADS)

    Barthelmes, Alexandra; Barthelmes, Karen-Doreen; Joosten, Hans; Dommain, Rene; Margalef, Olga

    2015-04-01

    discuss the perspectives and opportunities to complete a global map by collaborative action by 2020. References: Holden J., Chapman P.J., Labadz J.C. 2004 Artificial drainage of peatlands: hydrological and hydrochemical process and wetland restoration. Prog. Phys. Geogr, 28, 95-123. Joosten H. 2011. Sensitising global conventions for climate change mitigation by peatlands. In: Tanneberger F., Wichtmann W. (eds.) 2011. Carbon credits from peatland rewetting. Climate - biodiversity - land use. Science, policy, implementation and recommendations of a pilot project in Belarus. Schweizerbart, Stuttgart, p. 90-94. Joosten H., Tapio-Biström M.-L., Tol S. (eds.) 2012. Peatlands - guidance for climate change mitigation by conservation, rehabilitation and sustainable use. Mitigation of Climate Change in Agriculture Series 5. FAO, Rome, L + 96 p. http://www.fao.org/docrep/015/an762e/an762e.pdf. Victoria R., Banwart S., Black H., Ingram J., Joosten H., Milne E., Noellemeyer E. 2012. The benefits of soil carbon. Managing soils for multiple economic, societal, and environmental benefits. UNEP Yearbook 2012, UNEP, Nairobi, pp. 18-33.

  5. Towards a Global High Resolution Peatland Map in 2020

    NASA Astrophysics Data System (ADS)

    Barthelmes, Alexandra; Barthelmes, Karen-Doreen; Dommain, Rene; Margalef, Olga; Joosten, Hans

    2014-05-01

    the Southeast African countries Zambia, Zimbabwe, Mozambique and Malawi) and discuss the perspectives and opportunities to complete a global map by collaborative action by 2020. References: Holden J., Chapman P.J., Labadz J.C. 2004 Artificial drainage of peatlands: hydrological and hydrochemical process and wetland restoration. Prog. Phys. Geogr, 28, 95-123. Joosten H. 2011. Sensitising global conventions for climate change mitigation by peatlands. In: Tanneberger F., Wichtmann W. (eds.) 2011. Carbon credits from peatland rewetting. Climate - biodiversity - land use. Science, policy, implementation and recommendations of a pilot project in Belarus. Schweizerbart, Stuttgart, p. 90-94. Joosten H., Tapio-Biström M.-L., Tol S. (eds.) 2012. Peatlands - guidance for climate change mitigation by conservation, rehabilitation and sustainable use. Mitigation of Climate Change in Agriculture Series 5. FAO, Rome, L + 96 p. http://www.fao.org/docrep/015/an762e/an762e.pdf. Victoria R., Banwart S., Black H., Ingram J., Joosten H., Milne E., Noellemeyer E. 2012. The benefits of soil carbon. Managing soils for multiple economic, societal, and environmental benefits. UNEP Yearbook 2012, UNEP, Nairobi, pp. 18-33.

  6. Overcoming the risk of inaction from emissions uncertainty in smallholder agriculture

    NASA Astrophysics Data System (ADS)

    Berry, N. J.; Ryan, C. M.

    2013-03-01

    proof of this concept and a platform on which greater functionality and flexibility can be built. We hope that this, and other similar initiatives, will deliver approaches to greenhouse gas accounting that reduce risks and maximize benefits to smallholder farmers. References Beddington J R et al 2012 What next for agriculture after Durban? Science 335 289-90 Coleman K and Jenkinson D S 1996 RothC 26.3 a model for the turnover of carbon in soil Evaluation of Soil Organic Matter Models Using Existing, Long-Term Datasets ed D S Powlson, P Smith and J U Smith (Heidelberg: Springer) Del Grosso S J, Ojima D S, Parton W J, Mosier A R, Petereson G A and Schimel D S 2002 Simulated effects of dryland cropping intensification on soil organic matter and greenhouse gas exchanges using the DAYCENT ecosystem model Environ. Pollut. 116 S75-83 IPCC (Intergovenmental Panel on Climate Change) 2006 Guidelines for National Greenhouse Gas Inventories. Prepared by the National Greenhouse Gas Inventories Programme (Hayama: IGES) (www.ipcc-nggip.iges.or.jp/public/2006gl/index.html) Li C, Frolking S and Harris R 1994 Modeling carbon biogeochemistry in agricultural soils Glob. Biogeochem. Cycles 8 237-54 Milori D M B P, Segini A, Da Silva W T L, Posadas A, Mares V, Quiroz R and Ladislau M N 2012 Emerging techniques for soil carbon measurements Climate Change Mitigation and Agriculture ed E Wollenberg, A Nihart, M-L Tapio-Bistrom and M Greig-Gran (Abingdon: Earthscan) Olander L P 2012 Using biogeochemical process models to quantify greenhouse gas mitigation from agricultural management Climate Change Mitigation and Agriculture ed E Wollenberg, A Nihart, M-L Tapio-Bistrom and M Greig-Gran (Abingdon: Earthscan) Parton W J, Schimel D S, Cole C V and Ojima D S 1987 Analysis of factors controlling soil organic matter levels in Great Plains grasslands Soil Sci. Soc. Am. J. 51 1173-9 Plan Vivo 2012 The Plan Vivo Standard For Community Payments for Ecosystem Services Programmes Version 2012 (available

  7. Lung deposited surface area concentrations in a street canyon

    NASA Astrophysics Data System (ADS)

    Kuuluvainen, Heino; Hietikko, Riina; Järvinen, Anssi; Saukko, Erkka; Irjala, Matti; Niemi, Jarkko V.; Timonen, Hilkka; Keskinen, Jorma; Rönkkö, Topi

    2017-04-01

    during the year 2016. A short period of data was also analysed with respect to the emissions of individual vehicles by using a recorded video of the traffic fleet. As an example of the vertical profiles, Figure 1 shows the LDSA concentration as a function of the altitude. The data measured with a time resolution of one second is seen along with the values averaged for different altitude intervals. The effect of wind conditions and changes in the traffic fleet on the concentration profiles could be analysed. In addition to the vertical profiles, we were able to analyse the LDSA concentrations on the ground level with respect to long-term averages and rapid changes caused by different individual vehicles. This work was conducted in two different research projects. The INKA-ILMA/EAKR project was funded by Tekes, European Union, Finnish companies, Helsinki Region Environmental Authority (HSY), and cities of Tampere and Kuopio. The CITYZER project was funded by Tekes and Finnish companies. References: Marini, S., Buonanno, G., Stabile, L., Avino, P. (2015). Environ. Sci. Pollut. Res., 22 (3), 2051-2063. Kuuluvainen, H., Rönkkö, T., Järvinen, A., Saari, S., Karjalainen, P., Lähde, T., Pirjola, L., Niemi, J. V., Hillamo, R., Keskinen, J. (2016). Atmos. Environ., 136, 105-113.

  8. Global Cropland Area Database (GCAD) derived from Remote Sensing in Support of Food Security in the Twenty-first Century: Current Achievements and Future Possibilities

    USGS Publications Warehouse

    Teluguntla, Pardhasaradhi G.; Thenkabail, Prasad S.; Xiong, Jun N.; Gumma, Murali Krishna; Giri, Chandra; Milesi, Cristina; Ozdogan, Mutlu; Congalton, Russ; Tilton, James; Sankey, Temuulen Tsagaan; Massey, Richard; Phalke, Aparna; Yadav, Kamini

    2015-01-01

    to biofuels (Bindraban et al., 2009), limited water resources for irrigation expansion (Turral et al., 2009), limits on agricultural intensifications, loss of croplands to urbanization (Khan and Hanjra, 2008), increasing meat consumption (and associated demands on land and water) (Vinnari and Tapio, 2009), environmental infeasibility for cropland expansion (Gordon et al., 2009), and changing climate have all put pressure on our continued ability to sustain global food security in the twenty-first century. So, how does the World continue to meet its food and nutrition needs?. Solutions may come from bio-technology and precision farming, however developments in these fields are not currently moving at rates that will ensure global food security over next few decades. Further, there is a need for careful consideration of possible harmful effects of bio-technology. We should not be looking back 30– 50 years from now, like we have been looking back now at many mistakes made during the green revolution. During the green revolution the focus was only on getting more yield per unit area. Little thought was put about serious damage done to our natural environments, water resources, and human health as a result of detrimental factors such as uncontrolled use of herbicides-pesticides-nutrients, drastic groundwater mining, and salinization of fertile soils due to over irrigation. Currently, there is talk of a “second green revolution” or even an “ever green revolution”, but clear ideas on what these terms actually mean are still debated and are evolving. One of the biggest issues that are not given adequate focus is the use of large quantities of water for food production. Indeed, an overwhelming proportion (60-90%) of all human water use in India goes for producing their food (Falkenmark, M., & Rockström, 2006). But such intensive water use for food production is no longer tenable due to increasing pressure for water use alternatives such as increasing urbanization

  9. EDITORIAL: Incoming Editor-in-Chief

    NASA Astrophysics Data System (ADS)

    Lidström, Suzanne

    2012-04-01

    , in his hands, the expansion continued and the transition to electronic production took place. In 2005, an agreement was signed with IOP Publishing and the bustling production work of the in-house team moved abroad to Bristol, leaving just the Editor-in-Chief to man the ship at the Royal Swedish Academy of Sciences. In 2011, however, as Roger prepared to step down, submissions had reached astounding levels as is evident from figure 1: that year, almost 1500 manuscripts were received by Physica Scripta, now acknowledged to be amongst the fastest growing journals in IOP Publishing, when measured in these terms. The year on year increase stands at 20% and, once again, of the extensive range of topics covered, condensed matter physics had been identified as the subject area in most need of attention because the burden of reviewing had become too great for one editor to oversee alone. Thus, when I joined Physica Scripta in January of this year, securing new External Editors for this field was perceived to be the most urgent task. It is, therefore, with the greatest of pleasure that I am able to announce the arrival of two new editors for this section: Professors David Keen and Tapio Rantala. Physica Scripta statistics Figure 1. The annual submissions made to Physica Scripta in recent years have rocketed and the rejection rate (given as a percentage) has increased rapidly. The modest increase in the number of articles accepted (shaded in blue) reflects a deliberate policy to augment the scientific quality. Professor Rantala has been selected by the Finnish Physical Society to replace Professor Matti Manninen, who is stepping down as the Finnish representative on the journal's Editorial Board. Professor Rantala is a prominent theorist and has been engaged in active research in a number of fields. In his early work, he was interested in surface science and molecular physics, however his expertise is predominantly in the domain of solid or materials physics related to