Sample records for target end-uses range

  1. An end-to-end assessment of range uncertainty in proton therapy using animal tissues.

    PubMed

    Zheng, Yuanshui; Kang, Yixiu; Zeidan, Omar; Schreuder, Niek

    2016-11-21

    Accurate assessment of range uncertainty is critical in proton therapy. However, there is a lack of data and consensus on how to evaluate the appropriate amount of uncertainty. The purpose of this study is to quantify the range uncertainty in various treatment conditions in proton therapy, using transmission measurements through various animal tissues. Animal tissues, including a pig head, beef steak, and lamb leg, were used in this study. For each tissue, an end-to-end test closely imitating patient treatments was performed. This included CT scan simulation, treatment planning, image-guided alignment, and beam delivery. Radio-chromic films were placed at various depths in the distal dose falloff region to measure depth dose. Comparisons between measured and calculated doses were used to evaluate range differences. The dose difference at the distal falloff between measurement and calculation depends on tissue type and treatment conditions. The estimated range difference was up to 5, 6 and 4 mm for the pig head, beef steak, and lamb leg irradiation, respectively. Our study shows that the TPS was able to calculate proton range within about 1.5% plus 1.5 mm. Accurate assessment of range uncertainty in treatment planning would allow better optimization of proton beam treatment, thus fully achieving proton beams' superior dose advantage over conventional photon-based radiation therapy.

  2. 8. VIEW, LOOKING SOUTHEAST, SHOWING DETAIL OF RANGE 3 TARGET ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. VIEW, LOOKING SOUTHEAST, SHOWING DETAIL OF RANGE 3 TARGET END, Interior - Winchester Repeating Arms Company, Tract K Shooting Range, 125 Munson Street (rear section), New Haven, New Haven County, CT

  3. 6. VIEW, LOOKING SOUTHEAST, SHOWING DETAIL OF RANGE 1 TARGET ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW, LOOKING SOUTHEAST, SHOWING DETAIL OF RANGE 1 TARGET END, Interior - Winchester Repeating Arms Company, Tract K Shooting Range, 125 Munson Street (rear section), New Haven, New Haven County, CT

  4. Approach range and velocity determination using laser sensors and retroreflector targets

    NASA Technical Reports Server (NTRS)

    Donovan, William J.

    1991-01-01

    A laser docking sensor study is currently in the third year of development. The design concept is considered to be validated. The concept is based on using standard radar techniques to provide range, velocity, and bearing information. Multiple targets are utilized to provide relative attitude data. The design requirements were to utilize existing space-qualifiable technology and require low system power, weight, and size yet, operate from 0.3 to 150 meters with a range accuracy greater than 3 millimeters and a range rate accuracy greater than 3 mm per second. The field of regard for the system is +/- 20 deg. The transmitter and receiver design features a diode laser, microlens beam steering, and power control as a function of range. The target design consists of five target sets, each having seven 3-inch retroreflectors, arranged around the docking port. The target map is stored in the sensor memory. Phase detection is used for ranging, with the frequency range-optimized. Coarse bearing measurement is provided by the scanning system (one set of binary optics) angle. Fine bearing measurement is provided by a quad detector. A MIL-STD-1750 A/B computer is used for processing. Initial test results indicate a probability of detection greater than 99 percent and a probability of false alarm less than 0.0001. The functional system is currently at the MIT/Lincoln Lab for demonstration.

  5. Laser range profiling for small target recognition

    NASA Astrophysics Data System (ADS)

    Steinvall, Ove; Tulldahl, Michael

    2017-03-01

    Long range identification (ID) or ID at closer range of small targets has its limitations in imaging due to the demand for very high-transverse sensor resolution. This is, therefore, a motivation to look for one-dimensional laser techniques for target ID. These include laser vibrometry and laser range profiling. Laser vibrometry can give good results, but is not always robust as it is sensitive to certain vibrating parts on the target being in the field of view. Laser range profiling is attractive because the maximum range can be substantial, especially for a small laser beam width. A range profiler can also be used in a scanning mode to detect targets within a certain sector. The same laser can also be used for active imaging when the target comes closer and is angularly resolved. Our laser range profiler is based on a laser with a pulse width of 6 ns (full width half maximum). This paper will show both experimental and simulated results for laser range profiling of small boats out to a 6 to 7-km range and a unmanned arrial vehicle (UAV) mockup at close range (1.3 km). The naval experiments took place in the Baltic Sea using many other active and passive electro-optical sensors in addition to the profiling system. The UAV experiments showed the need for a high-range resolution, thus we used a photon counting system in addition to the more conventional profiler used in the naval experiments. This paper shows the influence of target pose and range resolution on the capability of classification. The typical resolution (in our case 0.7 m) obtainable with a conventional range finder type of sensor can be used for large target classification with a depth structure over 5 to 10 m or more, but for smaller targets such as a UAV a high resolution (in our case 7.5 mm) is needed to reveal depth structures and surface shapes. This paper also shows the need for 3-D target information to build libraries for comparison of measured and simulated range profiles. At closer ranges

  6. [Passive ranging of infrared target using oxygen A-band and Elsasser model].

    PubMed

    Li, Jin-Hua; Wang, Zhao-Ba; Wang Zhi

    2014-09-01

    Passive ranging method of short range and single band was developed based on target radiation and attenuation characteristic of oxygen spectrum absorption. The relation between transmittance of oxygen A band and range of measured target was analyzed. Radiation strength distribution of measured target can be obtained according to the distribution law of absorption coefficient with environmental parameters. Passive ranging mathematical model of short ranges was established using Elsasser model with Lorentz line shape based on the computational methods of band average transmittance and high-temperature gas radiation narrowband model. The range of measured object was obtained using transmittance fitting with test data calculation and theoretical model. Besides, ranging precision was corrected considering the influence of oxygen absorption with enviromental parameter. The ranging experiment platform was established. The source was a 10 watt black body, and a grating spectrometer with 17 cm(-1) resolution was used. In order to improve the light receiving efficiency, light input was collected with 23 mm calibre telescope. The test data was processed for different range in 200 m. The results show that the transmittance accuracy was better than 2.18% in short range compared to the test data with predicted value in the same conditions.

  7. Target recognition of log-polar ladar range images using moment invariants

    NASA Astrophysics Data System (ADS)

    Xia, Wenze; Han, Shaokun; Cao, Jie; Yu, Haoyong

    2017-01-01

    The ladar range image has received considerable attentions in the automatic target recognition field. However, previous research does not cover target recognition using log-polar ladar range images. Therefore, we construct a target recognition system based on log-polar ladar range images in this paper. In this system combined moment invariants and backpropagation neural network are selected as shape descriptor and shape classifier, respectively. In order to fully analyze the effect of log-polar sampling pattern on recognition result, several comparative experiments based on simulated and real range images are carried out. Eventually, several important conclusions are drawn: (i) if combined moments are computed directly by log-polar range images, translation, rotation and scaling invariant properties of combined moments will be invalid (ii) when object is located in the center of field of view, recognition rate of log-polar range images is less sensitive to the changing of field of view (iii) as object position changes from center to edge of field of view, recognition performance of log-polar range images will decline dramatically (iv) log-polar range images has a better noise robustness than Cartesian range images. Finally, we give a suggestion that it is better to divide field of view into recognition area and searching area in the real application.

  8. Laser range profiling for small target recognition

    NASA Astrophysics Data System (ADS)

    Steinvall, Ove; Tulldahl, Michael

    2016-05-01

    The detection and classification of small surface and airborne targets at long ranges is a growing need for naval security. Long range ID or ID at closer range of small targets has its limitations in imaging due to the demand on very high transverse sensor resolution. It is therefore motivated to look for 1D laser techniques for target ID. These include vibrometry, and laser range profiling. Vibrometry can give good results but is also sensitive to certain vibrating parts on the target being in the field of view. Laser range profiling is attractive because the maximum range can be substantial, especially for a small laser beam width. A range profiler can also be used in a scanning mode to detect targets within a certain sector. The same laser can also be used for active imaging when the target comes closer and is angular resolved. The present paper will show both experimental and simulated results for laser range profiling of small boats out to 6-7 km range and a UAV mockup at close range (1.3 km). We obtained good results with the profiling system both for target detection and recognition. Comparison of experimental and simulated range waveforms based on CAD models of the target support the idea of having a profiling system as a first recognition sensor and thus narrowing the search space for the automatic target recognition based on imaging at close ranges. The naval experiments took place in the Baltic Sea with many other active and passive EO sensors beside the profiling system. Discussion of data fusion between laser profiling and imaging systems will be given. The UAV experiments were made from the rooftop laboratory at FOI.

  9. 32 CFR 644.526 - Reporting target ranges.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Reporting target ranges. 644.526 Section 644.526... and Improvements § 644.526 Reporting target ranges. All Reports of Excess to GSA covering lands which have been used as target ranges of any kind will contain an affirmative or negative statement in regard...

  10. 32 CFR 644.526 - Reporting target ranges.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 4 2011-07-01 2011-07-01 false Reporting target ranges. 644.526 Section 644.526... and Improvements § 644.526 Reporting target ranges. All Reports of Excess to GSA covering lands which have been used as target ranges of any kind will contain an affirmative or negative statement in regard...

  11. Target recognition of ladar range images using even-order Zernike moments.

    PubMed

    Liu, Zheng-Jun; Li, Qi; Xia, Zhi-Wei; Wang, Qi

    2012-11-01

    Ladar range images have attracted considerable attention in automatic target recognition fields. In this paper, Zernike moments (ZMs) are applied to classify the target of the range image from an arbitrary azimuth angle. However, ZMs suffer from high computational costs. To improve the performance of target recognition based on small samples, even-order ZMs with serial-parallel backpropagation neural networks (BPNNs) are applied to recognize the target of the range image. It is found that the rotation invariance and classified performance of the even-order ZMs are both better than for odd-order moments and for moments compressed by principal component analysis. The experimental results demonstrate that combining the even-order ZMs with serial-parallel BPNNs can significantly improve the recognition rate for small samples.

  12. An experimental study of the reflection from spherical and flat ended cylindrical targets suitable for fetal Doppler performance assessment.

    PubMed

    Preston, R C; Bond, A D

    1997-01-01

    The performance of small-diameter targets suitable for use as oscillating targets for testing the sensitivity of Doppler fetal heartbeat detectors has been systematically studied. Experimental results are presented in the 1.6-3.0 MHz frequency range for the plane-wave reflection loss for a total of 16 targets: spherical balls made of stainless steel; hemispherical-ended rods made of PTFE; and flat-ended rods made of stainless steel, PTFE, polycarbonate, and tungsten carbide. Results show that the fine-structure variation of reflection loss with frequency is greatest in the case of spherical ball targets and least for flat-ended targets. It has been shown that, providing care is taken during manufacture, the reflection loss from a flat-ended target can be predicted using a simple theory based on a plane disc reflector. Tungsten carbide targets consisting of a long rod with a diameter of 1.6 mm tapered down to a cylindrical flat end with a diameter of 0.4, 0.5, and 0.6 mm have been shown to provide reflection losses of between 60 and 40 dB, and to have a smooth variation of reflection loss with frequency. They can also be manufactured in a form that allows no significant interference from the supporting structure and, therefore, are ideal targets to meet the requirements of International Electrotechnical Commission 1266:1995.

  13. NudEL targets dynein to microtubule ends through LIS1.

    PubMed

    Li, Jun; Lee, Wei-Lih; Cooper, John A

    2005-07-01

    Dynein is a minus-end-directed microtubule motor with critical roles in mitosis, membrane transport and intracellular transport. Several proteins regulate dynein activity, including dynactin, LIS1 (refs 2, 3) and NudEL (NudE-like). Here, we identify a NUDEL homologue in budding yeast and name it Ndl1. The ndl1delta null mutant shows decreased targeting of dynein to microtubule plus ends, an essential element of the model for dynein function. We find that Ndl1 regulates dynein targeting through LIS1, with which it interacts biochemically, but not through CLIP170, another plus-end protein involved in dynein targeting. Ndl1 is found at far fewer microtubule ends than are LIS1 and dynein. However, when Ndl1 is present at a plus end, the molar amount of Ndl1 approaches that of LIS1 and dynein. We propose a model in which Ndl1 binds transiently to the plus end to promote targeting of LIS1, which cooperatively recruits dynein.

  14. Model-based recognition of 3D articulated target using ladar range data.

    PubMed

    Lv, Dan; Sun, Jian-Feng; Li, Qi; Wang, Qi

    2015-06-10

    Ladar is suitable for 3D target recognition because ladar range images can provide rich 3D geometric surface information of targets. In this paper, we propose a part-based 3D model matching technique to recognize articulated ground military vehicles in ladar range images. The key of this approach is to solve the decomposition and pose estimation of articulated parts of targets. The articulated components were decomposed into isolate parts based on 3D geometric properties of targets, such as surface point normals, data histogram distribution, and data distance relationships. The corresponding poses of these separate parts were estimated through the linear characteristics of barrels. According to these pose parameters, all parts of the target were roughly aligned to 3D point cloud models in a library and fine matching was finally performed to accomplish 3D articulated target recognition. The recognition performance was evaluated with 1728 ladar range images of eight different articulated military vehicles with various part types and orientations. Experimental results demonstrated that the proposed approach achieved a high recognition rate.

  15. NudEL targets dynein to microtubule ends through LIS1

    PubMed Central

    Li, Jun; Lee, Wei-Lih; Cooper, John A.

    2006-01-01

    Dynein is a minus-end-directed microtubule motor with critical roles in mitosis, membrane transport and intracellular transport. Several proteins regulate dynein activity, including dynactin1, LIS1 (refs 2, 3) and NudEL (NudE-like)2,4–8. Here, we identify a NUDEL homologue in budding yeast and name it Ndl1. The ndl1Δ null mutant shows decreased targeting of dynein to microtubule plus ends, an essential element of the model for dynein function. We find that Ndl1 regulates dynein targeting through LIS1, with which it interacts biochemically, but not through CLIP170, another plus-end protein involved in dynein targeting9. Ndl1 is found at far fewer microtubule ends than are LIS1 and dynein. However, when Ndl1 is present at a plus end, the molar amount of Ndl1 approaches that of LIS1 and dynein. We propose a model in which Ndl1 binds transiently to the plus end to promote targeting of LIS1, which cooperatively recruits dynein. PMID:15965467

  16. An End-to-End Model of Plant Pheromone Channel for Long Range Molecular Communication.

    PubMed

    Unluturk, Bige D; Akyildiz, Ian F

    2017-01-01

    A new track in molecular communication is using pheromones which can scale up the range of diffusion-based communication from μm meters to meters and enable new applications requiring long range. Pheromone communication is the emission of molecules in the air which trigger behavioral or physiological responses in receiving organisms. The objective of this paper is to introduce a new end-to-end model which incorporates pheromone behavior with communication theory for plants. The proposed model includes both the transmission and reception processes as well as the propagation channel. The transmission process is the emission of pheromones from the leaves of plants. The dispersion of pheromones by the flow of wind constitutes the propagation process. The reception process is the sensing of pheromones by the pheromone receptors of plants. The major difference of pheromone communication from other molecular communication techniques is the dispersion channel acting under the laws of turbulent diffusion. In this paper, the pheromone channel is modeled as a Gaussian puff, i.e., a cloud of pheromone released instantaneously from the source whose dispersion follows a Gaussian distribution. Numerical results on the performance of the overall end-to-end pheromone channel in terms of normalized gain and delay are provided.

  17. Vocal reporting of echolocation targets: dolphins often report before click trains end.

    PubMed

    Ridgway, S H; Elsberry, W R; Blackwood, D J; Kamolnick, T; Todd, M; Carder, D A; Chaplin, Monica; Cranford, T W

    2012-01-01

    Bottlenose dolphins (Tursiops truncatus) wore opaque suction cups over their eyes while stationing behind an acoustically opaque door. This put the dolphins in a known position and orientation. When the door opened, the dolphin clicked to detect targets. Trainers specified that Dolphin S emit a whistle if the target was a 7.5 cm water filled sphere, or a pulse burst if the target was a rock. S remained quiet if there was no target. Dolphin B whistled for the sphere. She remained quiet for rock and for no target. Thus, S had to choose between three different responses, whistle, pulse burst, or remain quiet. B had to choose between two different responses, whistle or remain quiet. S gave correct vocal responses averaging 114 ms after her last echolocation click (range 182 ms before and 219 ms after the last click). Average response for B was 21 ms before her last echolocation click (range 250 ms before and 95 ms after the last click in the train). More often than not, B began her whistle response before her echolocation train ended. The findings suggest separate neural pathways for generation of response vocalizations as opposed to echolocation clicks. © 2012 Acoustical Society of America.

  18. Influence of target reflection on three-dimensional range gated reconstruction.

    PubMed

    Chua, Sing Yee; Wang, Xin; Guo, Ningqun; Tan, Ching Seong

    2016-08-20

    The range gated technique is a promising laser ranging method that is widely used in different fields such as surveillance, industry, and military. In a range gated system, a reflected laser pulse returned from the target scene contains key information for range reconstruction, which directly affects the system performance. Therefore, it is necessary to study the characteristics and effects of the target reflection factor. In this paper, theoretical and experimental analyses are performed to investigate the influence of target reflection on three-dimensional (3D) range gated reconstruction. Based on laser detection and ranging (LADAR) and bidirectional reflection distribution function (BRDF) theory, a 3D range gated reconstruction model is derived and the effect on range accuracy is analyzed from the perspectives of target surface reflectivity and angle of laser incidence. Our theoretical and experimental study shows that the range accuracy is proportional to the target surface reflectivity, but it decreases when the angle of incidence increases to adhere to the BRDF model. The presented findings establish a comprehensive understanding of target reflection in 3D range gated reconstruction, which is of interest to various applications such as target recognition and object modeling. This paper provides a reference for future improvement to perform accurate range compensation or correction.

  19. Prospects of using a permanent magnetic end effector to despin and detumble an uncooperative target

    NASA Astrophysics Data System (ADS)

    Liu, Xiaoguang; Lu, Yong; Zhou, Yu; Yin, Yuanhao

    2018-04-01

    Space debris, such as defunct satellites and upper stages of rockets, becomes an uncooperative target after losing its attitude control and communication ability. In addition, tumbling motion can occur due to environmental perturbations and residual angular momentum prior to the object's end-of-mission. To minimize the collision risk during docking and capturing of the tumbling target, a non-contact method based on the eddy current effect is put forward to transmit the control torque to the tumbling target. The main idea is to induce a controllable torque on the conducting surface of the tumbling target using a rotational magnetic field generated by a Halbach rotor. The radial and axial Halbach rotors are used to damp the spinning and nutation motions of the target, respectively. The normal and tangential force are evaluated concerning the relative pose between the chaser and the target. A simplified dynamic model of the nutation damping and despinning processes is developed and the influences of the asymmetrical principal moments of inertia and transverse angular velocity are discussed. The numerical simulation results show that the designed Halbach rotor stabilized the target attitude within an acceptable time. The electromagnetic nutation damping and despinning method provides new solutions for the development of on-orbit capture technology.

  20. Relative range error evaluation of terrestrial laser scanners using a plate, a sphere, and a novel dual-sphere-plate target.

    PubMed

    Muralikrishnan, Bala; Rachakonda, Prem; Lee, Vincent; Shilling, Meghan; Sawyer, Daniel; Cheok, Geraldine; Cournoyer, Luc

    2017-12-01

    Terrestrial laser scanners (TLS) are a class of 3D imaging systems that produce a 3D point cloud by measuring the range and two angles to a point. The fundamental measurement of a TLS is range. Relative range error is one component of the overall range error of TLS and its estimation is therefore an important aspect in establishing metrological traceability of measurements performed using these systems. Target geometry is an important aspect to consider when realizing the relative range tests. The recently published ASTM E2938-15 mandates the use of a plate target for the relative range tests. While a plate target may reasonably be expected to produce distortion free data even at far distances, the target itself needs careful alignment at each of the relative range test positions. In this paper, we discuss relative range experiments performed using a plate target and then address the advantages and limitations of using a sphere target. We then present a novel dual-sphere-plate target that draws from the advantages of the sphere and the plate without the associated limitations. The spheres in the dual-sphere-plate target are used simply as fiducials to identify a point on the surface of the plate that is common to both the scanner and the reference instrument, thus overcoming the need to carefully align the target.

  1. Range estimation of passive infrared targets through the atmosphere

    NASA Astrophysics Data System (ADS)

    Cho, Hoonkyung; Chun, Joohwan; Seo, Doochun; Choi, Seokweon

    2013-04-01

    Target range estimation is traditionally based on radar and active sonar systems in modern combat systems. However, jamming signals tremendously degrade the performance of such active sensor devices. We introduce a simple target range estimation method and the fundamental limits of the proposed method based on the atmosphere propagation model. Since passive infrared (IR) sensors measure IR signals radiating from objects in different wavelengths, this method has robustness against electromagnetic jamming. The measured target radiance of each wavelength at the IR sensor depends on the emissive properties of target material and various attenuation factors (i.e., the distance between sensor and target and atmosphere environment parameters). MODTRAN is a tool that models atmospheric propagation of electromagnetic radiation. Based on the results from MODTRAN and atmosphere propagation-based modeling, the target range can be estimated. To analyze the proposed method's performance statistically, we use maximum likelihood estimation (MLE) and evaluate the Cramer-Rao lower bound (CRLB) via the probability density function of measured radiance. We also compare CRLB and the variance of MLE using Monte-Carlo simulation.

  2. Effects of Resolution, Range, and Image Contrast on Target Acquisition Performance.

    PubMed

    Hollands, Justin G; Terhaar, Phil; Pavlovic, Nada J

    2018-05-01

    We sought to determine the joint influence of resolution, target range, and image contrast on the detection and identification of targets in simulated naturalistic scenes. Resolution requirements for target acquisition have been developed based on threshold values obtained using imaging systems, when target range was fixed, and image characteristics were determined by the system. Subsequent work has examined the influence of factors like target range and image contrast on target acquisition. We varied the resolution and contrast of static images in two experiments. Participants (soldiers) decided whether a human target was located in the scene (detection task) or whether a target was friendly or hostile (identification task). Target range was also varied (50-400 m). In Experiment 1, 30 participants saw color images with a single target exemplar. In Experiment 2, another 30 participants saw monochrome images containing different target exemplars. The effects of target range and image contrast were qualitatively different above and below 6 pixels per meter of target for both tasks in both experiments. Target detection and identification performance were a joint function of image resolution, range, and contrast for both color and monochrome images. The beneficial effects of increasing resolution for target acquisition performance are greater for closer (larger) targets.

  3. Practical target location and accuracy indicator in digital close range photogrammetry using consumer grade cameras

    NASA Astrophysics Data System (ADS)

    Moriya, Gentaro; Chikatsu, Hirofumi

    2011-07-01

    Recently, pixel numbers and functions of consumer grade digital camera are amazingly increasing by modern semiconductor and digital technology, and there are many low-priced consumer grade digital cameras which have more than 10 mega pixels on the market in Japan. In these circumstances, digital photogrammetry using consumer grade cameras is enormously expected in various application fields. There is a large body of literature on calibration of consumer grade digital cameras and circular target location. Target location with subpixel accuracy had been investigated as a star tracker issue, and many target location algorithms have been carried out. It is widely accepted that the least squares models with ellipse fitting is the most accurate algorithm. However, there are still problems for efficient digital close range photogrammetry. These problems are reconfirmation of the target location algorithms with subpixel accuracy for consumer grade digital cameras, relationship between number of edge points along target boundary and accuracy, and an indicator for estimating the accuracy of normal digital close range photogrammetry using consumer grade cameras. With this motive, an empirical testing of several algorithms for target location with subpixel accuracy and an indicator for estimating the accuracy are investigated in this paper using real data which were acquired indoors using 7 consumer grade digital cameras which have 7.2 mega pixels to 14.7 mega pixels.

  4. Radiance and atmosphere propagation-based method for the target range estimation

    NASA Astrophysics Data System (ADS)

    Cho, Hoonkyung; Chun, Joohwan

    2012-06-01

    Target range estimation is traditionally based on radar and active sonar systems in modern combat system. However, the performance of such active sensor devices is degraded tremendously by jamming signal from the enemy. This paper proposes a simple range estimation method between the target and the sensor. Passive IR sensors measures infrared (IR) light radiance radiating from objects in dierent wavelength and this method shows robustness against electromagnetic jamming. The measured target radiance of each wavelength at the IR sensor depends on the emissive properties of target material and is attenuated by various factors, in particular the distance between the sensor and the target and atmosphere environment. MODTRAN is a tool that models atmospheric propagation of electromagnetic radiation. Based on the result from MODTRAN and measured radiance, the target range is estimated. To statistically analyze the performance of proposed method, we use maximum likelihood estimation (MLE) and evaluate the Cramer-Rao Lower Bound (CRLB) via the probability density function of measured radiance. And we also compare CRLB and the variance of and ML estimation using Monte-Carlo.

  5. Progress in sensor performance testing, modeling and range prediction using the TOD method: an overview

    NASA Astrophysics Data System (ADS)

    Bijl, Piet; Hogervorst, Maarten A.; Toet, Alexander

    2017-05-01

    The Triangle Orientation Discrimination (TOD) methodology includes i) a widely applicable, accurate end-to-end EO/IR sensor test, ii) an image-based sensor system model and iii) a Target Acquisition (TA) range model. The method has been extensively validated against TA field performance for a wide variety of well- and under-sampled imagers, systems with advanced image processing techniques such as dynamic super resolution and local adaptive contrast enhancement, and sensors showing smear or noise drift, for both static and dynamic test stimuli and as a function of target contrast. Recently, significant progress has been made in various directions. Dedicated visual and NIR test charts for lab and field testing are available and thermal test benches are on the market. Automated sensor testing using an objective synthetic human observer is within reach. Both an analytical and an image-based TOD model have recently been developed and are being implemented in the European Target Acquisition model ECOMOS and in the EOSTAR TDA. Further, the methodology is being applied for design optimization of high-end security camera systems. Finally, results from a recent perception study suggest that DRI ranges for real targets can be predicted by replacing the relevant distinctive target features by TOD test patterns of the same characteristic size and contrast, enabling a new TA modeling approach. This paper provides an overview.

  6. Scapular Contribution for the End-Range of Shoulder Axial Rotation in Overhead Athletes

    PubMed Central

    Ribeiro, Andrea; Pascoal, Augusto Gil

    2012-01-01

    The aim of this study was to analyze the relative contribution of the scapular motion on the extreme range-of-motion of shoulder external and internal rotation, in overhead athletes. An electromagnetic tracking device (Flock of Birds) was used to record humeral and scapular kinematics. The dominant arm of 26 male subjects (13 athletes and 13 non-athletes) was studied while subjects actively reached end-range of internal and external rotation. Humeral and scapular angles were calculated and compared across groups by means of a t-test for independent samples. A bivariate correlation approach was used to describe the relationship between humeral angles and scapular variables. The range-of-motion of the thoracohumeral angles, during shoulder external rotation was significantly less (p < 0.05) on the athletes group, athletes also positioned their dominant scapula more retracted and posteriorly tilted. A positive correlation was found between glenohumeral angles and scapular tilt (r = 0.6777; p < 0.05). Concerning internal rotation; athletes showed significantly greater (highest) thoracohumeral angles (p < 0.05). Scapula assumed a position more in retraction and anterior tilt. Based on these findings, it is suggested that differences found in athletes seem to reveal an eventual shoulder adaptation to the throwing mechanics. Key points In external rotation end-range, athletes positioned their scapula more in retraction and posterior tilt. In internal rotation end-range, athletes positioned their scapula more in retraction and anterior tilt. Results seem to reveal a sport-related shoulder adaptation. PMID:24150078

  7. WE-G-BRD-08: End-To-End Targeting Accuracy of the Gamma Knife for Trigeminal Neuralgia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brezovich, I; Wu, X; Duan, J

    2014-06-15

    Purpose: Current QA procedures verify accuracy of individual equipment parameters, but may not include CT and MRI localizers. This study uses an end-to-end approach to measure the overall targeting errors in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 inch) diameter MRI contrast-filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the cavity position matches the Gamma Knife coordinates of 10 previously treated patients. Gafchromic EBT2 film is placed at the center of the cavity in coronal andmore » sagittal orientations. The films are marked with a pin prick to identify the cavity center. Treatments are planned for delivery with 4 mm collimators using MRI and CT scans acquired with the clinical localizer boxes and acquisition protocols. Coordinates of shots are chosen so that the cavity is centered within the 50% isodose volume. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pin prick and the centroid of the 50% isodose line. Results: Averaged over 10 patient simulations, targeting errors along the x, y and z coordinates (patient left-to-right, posterior-anterior, head-to-foot) were, respectively, −0.060 +/− 0.363, −0.350 +/− 0.253, and 0.364 +/− 0.191 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely 0.109 +/− 0.167, −0.191 +/− 0.144, and 0.211 +/− 0.94 mm. The largest errors in MRI and CT planned treatments were, respectively, y = −0.761 and x = 0.428 mm. Conclusion: Unless patient motion or stronger MRI image distortion in actual treatments caused additional errors, all patients received the prescribed dose, i.e., the targeted section of the trig±eminal nerve was contained within the 50% isodose surface in all cases.« less

  8. Prospective targeting and control of end-tidal CO2 and O2 concentrations

    PubMed Central

    Slessarev, Marat; Han, Jay; Mardimae, Alexandra; Prisman, Eitan; Preiss, David; Volgyesi, George; Ansel, Cliff; Duffin, James; Fisher, Joseph A

    2007-01-01

    Current methods of forcing end-tidal PCO2 (PETCO2) and PO2 (PETO2) rely on breath-by-breath adjustment of inspired gas concentrations using feedback loop algorithms. Such servo-control mechanisms are complex because they have to anticipate and compensate for the respiratory response to a given inspiratory gas concentration on a breath-by-breath basis. In this paper, we introduce a low gas flow method to prospectively target and control PETCO2 and PETO2 independent of each other and of minute ventilation in spontaneously breathing humans. We used the method to change PETCO2 from control (40 mmHg for PETCO2 and 100 mmHg for PETO2) to two target PETCO2 values (45 and 50 mmHg) at iso-oxia (100 mmHg), PETO2 to two target values (200 and 300 mmHg) at normocapnia (40 mmHg), and PETCO2 with PETO2 simultaneously to the same targets (45 with 200 mmHg and 50 with 300 mmHg). After each targeted value, PETCO2 and PETO2 were returned to control values. Each state was maintained for 30 s. The average difference between target and measured values for PETCO2 was ± 1 mmHg, and for PETO2 was ± 4 mmHg. PETCO2 varied by ± 1 mmHg and PETO2 by ± 5.6 mmHg (s.d.) over the 30 s stages. This degree of control was obtained despite considerable variability in minute ventilation between subjects (± 7.6 l min−1). We conclude that targeted end-tidal gas concentrations can be attained in spontaneously breathing subjects using this prospective, feed-forward, low gas flow system. PMID:17446225

  9. A robust close-range photogrammetric target extraction algorithm for size and type variant targets

    NASA Astrophysics Data System (ADS)

    Nyarko, Kofi; Thomas, Clayton; Torres, Gilbert

    2016-05-01

    The Photo-G program conducted by Naval Air Systems Command at the Atlantic Test Range in Patuxent River, Maryland, uses photogrammetric analysis of large amounts of real-world imagery to characterize the motion of objects in a 3-D scene. Current approaches involve several independent processes including target acquisition, target identification, 2-D tracking of image features, and 3-D kinematic state estimation. Each process has its own inherent complications and corresponding degrees of both human intervention and computational complexity. One approach being explored for automated target acquisition relies on exploiting the pixel intensity distributions of photogrammetric targets, which tend to be patterns with bimodal intensity distributions. The bimodal distribution partitioning algorithm utilizes this distribution to automatically deconstruct a video frame into regions of interest (ROI) that are merged and expanded to target boundaries, from which ROI centroids are extracted to mark target acquisition points. This process has proved to be scale, position and orientation invariant, as well as fairly insensitive to global uniform intensity disparities.

  10. Studies on Training Ground Observers to Estimate Range to Aerial Targets.

    ERIC Educational Resources Information Center

    McCluskey, Michael R.; And Others

    Six pilot studies were conducted to determine the effects of training on range estimation performance for aerial targets, and to identify some of the relevant variables. Observers were trained to estimate ranges of 350, 400, 800, 1,500, or 2,500 meters. Several variations of range estimation training methods were used, including immediate…

  11. Passive range estimation using dual baseline triangulation

    NASA Astrophysics Data System (ADS)

    Pieper, Ronald J.; Cooper, Alfred W.; Pelegris, G.

    1996-03-01

    Modern combat systems based on active radar sensing suffer disadvantages against low-flying targets in cluttered backgrounds. Use of passive infrared sensors with these systems, either in cooperation or as an alternative, shows potential for improving target detection and declaration range for targets crossing the horizon. Realization of this potential requires fusion of target position data from dissimilar sensors, or passive sensor measurement of target range. The availability of passive sensors that can supply both range and bearing data on such targets would significantly extend the robustness of an integrated ship self-defense system. This paper considers a new method of range determination with passive sensors based on the principle of triangulation, extending the principle to two orthogonal baselines. The performance of single or double baseline triangulation depends on sensor bearing precision and direction to target. An expression for maximum triangulation range at a required accuracy is derived as a function of polar angle relative to the center of the dual-baseline system. Limitations in the dual- baseline model due to the geometrically assessed horizon are also considered.

  12. In vivo gene correction with targeted sequence substitution through microhomology-mediated end joining.

    PubMed

    Shin, Jeong Hong; Jung, Soobin; Ramakrishna, Suresh; Kim, Hyongbum Henry; Lee, Junwon

    2018-07-07

    Genome editing technology using programmable nucleases has rapidly evolved in recent years. The primary mechanism to achieve precise integration of a transgene is mainly based on homology-directed repair (HDR). However, an HDR-based genome-editing approach is less efficient than non-homologous end-joining (NHEJ). Recently, a microhomology-mediated end-joining (MMEJ)-based transgene integration approach was developed, showing feasibility both in vitro and in vivo. We expanded this method to achieve targeted sequence substitution (TSS) of mutated sequences with normal sequences using double-guide RNAs (gRNAs), and a donor template flanking the microhomologies and target sequence of the gRNAs in vitro and in vivo. Our method could realize more efficient sequence substitution than the HDR-based method in vitro using a reporter cell line, and led to the survival of a hereditary tyrosinemia mouse model in vivo. The proposed MMEJ-based TSS approach could provide a novel therapeutic strategy, in addition to HDR, to achieve gene correction from a mutated sequence to a normal sequence. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Acoustic ranging of small arms fire using a single sensor node collocated with the target.

    PubMed

    Lo, Kam W; Ferguson, Brian G

    2015-06-01

    A ballistic model-based method, which builds upon previous work by Lo and Ferguson [J. Acoust. Soc. Am. 132, 2997-3017 (2012)], is described for ranging small arms fire using a single acoustic sensor node collocated with the target, without a priori knowledge of the muzzle speed and ballistic constant of the bullet except that they belong to a known two-dimensional parameter space. The method requires measurements of the differential time of arrival and differential angle of arrival of the muzzle blast and ballistic shock wave at the sensor node. Its performance is evaluated using both simulated and real data.

  14. Toward Realization of 2.4 GHz Balunless Narrowband Receiver Front-End for Short Range Wireless Applications.

    PubMed

    El-Desouki, Munir M; Qasim, Syed Manzoor; BenSaleh, Mohammed S; Deen, M Jamal

    2015-05-07

    The demand for radio frequency (RF) transceivers operating at 2.4 GHz band has attracted considerable research interest due to the advancement in short range wireless technologies. The performance of RF transceivers depends heavily on the transmitter and receiver front-ends. The receiver front-end is comprised of a low-noise amplifier (LNA) and a downconversion mixer. There are very few designs that focus on connecting the single-ended output LNA to a double-balanced mixer without the use of on-chip transformer, also known as a balun. The objective of designing such a receiver front-end is to achieve high integration and low power consumption. To meet these requirements, we present the design of fully-integrated 2.4 GHz receiver front-end, consisting of a narrow-band LNA and a double balanced mixer without using a balun. Here, the single-ended RF output signal of the LNA is translated into differential signal using an NMOS-PMOS (n-channel metal-oxide-semiconductor, p-channel metal-oxide-semiconductor) transistor differential pair instead of the conventional NMOS-NMOS transistor configuration, for the RF amplification stage of the double-balanced mixer. The proposed receiver circuit fabricated using TSMC 0.18 µm CMOS technology operates at 2.4 GHz and produces an output signal at 300 MHz. The fabricated receiver achieves a gain of 16.3 dB and consumes only 6.74 mW operating at 1.5 V, while utilizing 2.08 mm2 of chip area. Measurement results demonstrate the effectiveness and suitability of the proposed receiver for short-range wireless applications, such as in wireless sensor network (WSN).

  15. Performing target specific band reduction using artificial neural networks and assessment of its efficacy using various target detection algorithms

    NASA Astrophysics Data System (ADS)

    Yadav, Deepti; Arora, M. K.; Tiwari, K. C.; Ghosh, J. K.

    2016-04-01

    Hyperspectral imaging is a powerful tool in the field of remote sensing and has been used for many applications like mineral detection, detection of landmines, target detection etc. Major issues in target detection using HSI are spectral variability, noise, small size of the target, huge data dimensions, high computation cost, complex backgrounds etc. Many of the popular detection algorithms do not work for difficult targets like small, camouflaged etc. and may result in high false alarms. Thus, target/background discrimination is a key issue and therefore analyzing target's behaviour in realistic environments is crucial for the accurate interpretation of hyperspectral imagery. Use of standard libraries for studying target's spectral behaviour has limitation that targets are measured in different environmental conditions than application. This study uses the spectral data of the same target which is used during collection of the HSI image. This paper analyze spectrums of targets in a way that each target can be spectrally distinguished from a mixture of spectral data. Artificial neural network (ANN) has been used to identify the spectral range for reducing data and further its efficacy for improving target detection is verified. The results of ANN proposes discriminating band range for targets; these ranges were further used to perform target detection using four popular spectral matching target detection algorithm. Further, the results of algorithms were analyzed using ROC curves to evaluate the effectiveness of the ranges suggested by ANN over full spectrum for detection of desired targets. In addition, comparative assessment of algorithms is also performed using ROC.

  16. Long-range and depth-selective imaging of macroscopic targets using low-coherence and wide-field interferometry (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Woo, Sungsoo; Kang, Sungsam; Yoon, Changhyeong; Choi, Wonshik

    2016-03-01

    With the advancement of 3D display technology, 3D imaging of macroscopic objects has drawn much attention as they provide the contents to display. The most widely used imaging methods include a depth camera, which measures time of flight for the depth discrimination, and various structured illumination techniques. However, these existing methods have poor depth resolution, which makes imaging complicated structures a difficult task. In order to resolve this issue, we propose an imaging system based upon low-coherence interferometry and off-axis digital holographic imaging. By using light source with coherence length of 200 micro, we achieved the depth resolution of 100 micro. In order to map the macroscopic objects with this high axial resolution, we installed a pair of prisms in the reference beam path for the long-range scanning of the optical path length. Specifically, one prism was fixed in position, and the other prism was mounted on a translation stage and translated in parallel to the first prism. Due to the multiple internal reflections between the two prisms, the overall path length was elongated by a factor of 50. In this way, we could cover a depth range more than 1 meter. In addition, we employed multiple speckle illuminations and incoherent averaging of the acquired holographic images for reducing the specular reflections from the target surface. Using this newly developed system, we performed imaging targets with multiple different layers and demonstrated imaging targets hidden behind the scattering layers. The method was also applied to imaging targets located around the corner.

  17. Short-range/Long-range Integrated Target (SLIT) for Video Guidance Sensor Rendezvous and Docking

    NASA Technical Reports Server (NTRS)

    Roe, Fred D. (Inventor); Bryan, Thomas C. (Inventor)

    2009-01-01

    A laser target reflector assembly for mounting upon spacecraft having a long-range reflector array formed from a plurality of unfiltered light reflectors embedded in an array pattern upon a hemispherical reflector disposed upon a mounting plate. The reflector assembly also includes a short-range reflector array positioned upon the mounting body proximate to the long-range reflector array. The short-range reflector array includes three filtered light reflectors positioned upon extensions from the mounting body. The three filtered light reflectors retro-reflect substantially all incident light rays that are transmissive by their monochromatic filters and received by the three filtered light reflectors. In one embodiment the short-range reflector array is embedded within the hemispherical reflector,

  18. Acute effects of static stretching on peak and end-range hamstring-to-quadriceps functional ratios.

    PubMed

    Sekir, Ufuk; Arabaci, Ramiz; Akova, Bedrettin

    2015-10-18

    To evaluate if static stretching influences peak and end-range functional hamstring-to-quadriceps (H/Q) strength ratios in elite women athletes. Eleven healthy female athletes in an elite competitive level participated to the study. All the participants fulfilled the static stretching or non-stretching (control) intervention protocol in a randomized design on different days. Two static unassisted stretching exercises, one in standing and one in sitting position, were used to stretch both the hamstring and quadriceps muscles during these protocols. The total time for the static stretching was 6 ± 1 min. The isokinetic peak torque measurements for the hamstring and quadriceps muscles in eccentric and concentric modes and the calculations for the functional H/Q strength ratios at angular velocities of 60°/s and 180°/s were made before (pre) and after (post) the control or stretching intervention. The strength measurements and functional strength ratio calculations were based during the entire- and end-range of knee extension. The pre-test scores for quadriceps and hamstring peak torque and end range values were not significantly different between the groups (P > 0.05). Subsequently, although the control group did not exhibit significant changes in quadriceps and hamstring muscle strength (P > 0.05), static stretching decreased eccentric and concentric quadriceps muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). Similarly, static stretching also decreased eccentric and concentric hamstring muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). On the other hand, when the functional H/Q strength ratios were taken into consideration, the pre-intervention values were not significant different between the groups both during the entire and end range of knee extension (P > 0.05). Furthermore, the functional H/Q strength ratios exhibited no significant alterations during the entire and end ranges of knee extension both in the static

  19. Acute effects of static stretching on peak and end-range hamstring-to-quadriceps functional ratios

    PubMed Central

    Sekir, Ufuk; Arabaci, Ramiz; Akova, Bedrettin

    2015-01-01

    AIM: To evaluate if static stretching influences peak and end-range functional hamstring-to-quadriceps (H/Q) strength ratios in elite women athletes. METHODS: Eleven healthy female athletes in an elite competitive level participated to the study. All the participants fulfilled the static stretching or non-stretching (control) intervention protocol in a randomized design on different days. Two static unassisted stretching exercises, one in standing and one in sitting position, were used to stretch both the hamstring and quadriceps muscles during these protocols. The total time for the static stretching was 6 ± 1 min. The isokinetic peak torque measurements for the hamstring and quadriceps muscles in eccentric and concentric modes and the calculations for the functional H/Q strength ratios at angular velocities of 60°/s and 180°/s were made before (pre) and after (post) the control or stretching intervention. The strength measurements and functional strength ratio calculations were based during the entire- and end-range of knee extension. RESULTS: The pre-test scores for quadriceps and hamstring peak torque and end range values were not significantly different between the groups (P > 0.05). Subsequently, although the control group did not exhibit significant changes in quadriceps and hamstring muscle strength (P > 0.05), static stretching decreased eccentric and concentric quadriceps muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). Similarly, static stretching also decreased eccentric and concentric hamstring muscle strength at both the 60°/s and 180°/s test speeds (P < 0.01). On the other hand, when the functional H/Q strength ratios were taken into consideration, the pre-intervention values were not significant different between the groups both during the entire and end range of knee extension (P > 0.05). Furthermore, the functional H/Q strength ratios exhibited no significant alterations during the entire and end ranges of knee extension

  20. Using Design Capability Indices to Satisfy Ranged Sets of Design Requirements

    NASA Technical Reports Server (NTRS)

    Chen, Wei; Allen, Janet K.; Simpson, Timothy W.; Mistree, Farrokh

    1996-01-01

    For robust design it is desirable to allow the design requirements to vary within a certain range rather than setting point targets. This is particularly important during the early stages of design when little is known about the system and its requirements. Toward this end, design capability indices are developed in this paper to assess the capability of a family of designs, represented by a range of top-level design specifications, to satisfy a ranged set of design requirements. Design capability indices are based on process capability indices from statistical process control and provide a single objective, alternate approach to the use of Taguchi's signal-to- noise ratio which is often used for robust design. Successful implementation of design capability indices ensures that a family of designs conforms to a given ranged set of design requirements. To demonstrate an application and the usefulness of design capability indices, the design of a solar powered irrigation system is presented. Our focus in this paper is on the development and implementation of design capability indices as an alternate approach to the use of the signal-to-noise ratio and not on the results of the example problem, per se.

  1. The end-state comfort effect in bimanual grip selection.

    PubMed

    Fischman, Mark G; Stodden, David F; Lehman, Davana M

    2003-03-01

    During a unimanual grip selection task in which people pick up a lightweight dowel and place one end against targets at variable heights, the choice of hand grip (overhand vs. underhand) typically depends on the perception of how comfortable the arm will be at the end of the movement: an end-state comfort effect. The two experiments reported here extend this work to bimanual tasks. In each experiment, 26 right-handed participants used their left and right hands to simultaneously pick up two wooden dowels and place either the right or left end against a series of 14 targets ranging from 14 to 210 cm above the floor. These tasks were performed in systematic ascending and descending orders in Experiment 1 and in random order in Expiment 2. Results were generally consistent with predictions of end-state comfort in that, for the extreme highest and lowest targets, participants tended to select opposite grips with each hand. Taken together, our findings are consistent with the concept of constraint hierarchies within a posture-based motion-planning model.

  2. Target recognition for ladar range image using slice image

    NASA Astrophysics Data System (ADS)

    Xia, Wenze; Han, Shaokun; Wang, Liang

    2015-12-01

    A shape descriptor and a complete shape-based recognition system using slice images as geometric feature descriptor for ladar range images are introduced. A slice image is a two-dimensional image generated by three-dimensional Hough transform and the corresponding mathematical transformation. The system consists of two processes, the model library construction and recognition. In the model library construction process, a series of range images are obtained after the model object is sampled at preset attitude angles. Then, all the range images are converted into slice images. The number of slice images is reduced by clustering analysis and finding a representation to reduce the size of the model library. In the recognition process, the slice image of the scene is compared with the slice image in the model library. The recognition results depend on the comparison. Simulated ladar range images are used to analyze the recognition and misjudgment rates, and comparison between the slice image representation method and moment invariants representation method is performed. The experimental results show that whether in conditions without noise or with ladar noise, the system has a high recognition rate and low misjudgment rate. The comparison experiment demonstrates that the slice image has better representation ability than moment invariants.

  3. End-to-end tests using alanine dosimetry in scanned proton beams

    NASA Astrophysics Data System (ADS)

    Carlino, A.; Gouldstone, C.; Kragl, G.; Traneus, E.; Marrale, M.; Vatnitsky, S.; Stock, M.; Palmans, H.

    2018-03-01

    This paper describes end-to-end test procedures as the last fundamental step of medical commissioning before starting clinical operation of the MedAustron synchrotron-based pencil beam scanning (PBS) therapy facility with protons. One in-house homogeneous phantom and two anthropomorphic heterogeneous (head and pelvis) phantoms were used for end-to-end tests at MedAustron. The phantoms were equipped with alanine detectors, radiochromic films and ionization chambers. The correction for the ‘quenching’ effect of alanine pellets was implemented in the Monte Carlo platform of the evaluation version of RayStation TPS. During the end-to-end tests, the phantoms were transferred through the workflow like real patients to simulate the entire clinical workflow: immobilization, imaging, treatment planning and dose delivery. Different clinical scenarios of increasing complexity were simulated: delivery of a single beam, two oblique beams without and with range shifter. In addition to the dose comparison in the plastic phantoms the dose obtained from alanine pellet readings was compared with the dose determined with the Farmer ionization chamber in water. A consistent systematic deviation of about 2% was found between alanine dosimetry and the ionization chamber dosimetry in water and plastic materials. Acceptable agreement of planned and delivered doses was observed together with consistent and reproducible results of the end-to-end testing performed with different dosimetric techniques (alanine detectors, ionization chambers and EBT3 radiochromic films). The results confirmed the adequate implementation and integration of the new PBS technology at MedAustron. This work demonstrates that alanine pellets are suitable detectors for end-to-end tests in proton beam therapy and the developed procedures with customized anthropomorphic phantoms can be used to support implementation of PBS technology in clinical practice.

  4. Target recognition of ladar range images using slice image: comparison of four improved algorithms

    NASA Astrophysics Data System (ADS)

    Xia, Wenze; Han, Shaokun; Cao, Jingya; Wang, Liang; Zhai, Yu; Cheng, Yang

    2017-07-01

    Compared with traditional 3-D shape data, ladar range images possess properties of strong noise, shape degeneracy, and sparsity, which make feature extraction and representation difficult. The slice image is an effective feature descriptor to resolve this problem. We propose four improved algorithms on target recognition of ladar range images using slice image. In order to improve resolution invariance of the slice image, mean value detection instead of maximum value detection is applied in these four improved algorithms. In order to improve rotation invariance of the slice image, three new improved feature descriptors-which are feature slice image, slice-Zernike moments, and slice-Fourier moments-are applied to the last three improved algorithms, respectively. Backpropagation neural networks are used as feature classifiers in the last two improved algorithms. The performance of these four improved recognition systems is analyzed comprehensively in the aspects of the three invariances, recognition rate, and execution time. The final experiment results show that the improvements for these four algorithms reach the desired effect, the three invariances of feature descriptors are not directly related to the final recognition performance of recognition systems, and these four improved recognition systems have different performances under different conditions.

  5. The big brown bat's perceptual dimension of target range

    NASA Astrophysics Data System (ADS)

    Simmons, James A.

    2005-09-01

    Big brown bats determine the distance to targets from echo delay, but information actually is entered onto the bat's psychological delay scale from two sources. The first is the target-ranging system itself, from the time that elapses between single-spike neural responses evoked by the broadcast and similar responses evoked by echoes at different delays. These responses register the FM sweeps of broadcasts or echoes, and the associated system of neural delay lines and coincidence detectors cross correlates the spectrograms along the time axis. The second source is the echo spectrum, which relates to shape expressed as range profile. The target-ranging system extracts this by fanning out to encompass parallel representations of many possible notch frequencies and notch widths in echoes. Bats perceive delay separations of 5-30 μs and have a resolution limit of about 2 μs, but interference amplifies small delay separations by transposing them into large changes in notch frequency, so only perception of intervals smaller than 5 μs is surprising. Experiments with phase-shifted echoes show that the psychological time scale can represent two different delays originating entirely in the time domain when they are at least as close together as 10 μs. [Work supported by NIH and ONR.

  6. Three-Dimensional ISAR Imaging Method for High-Speed Targets in Short-Range Using Impulse Radar Based on SIMO Array.

    PubMed

    Zhou, Xinpeng; Wei, Guohua; Wu, Siliang; Wang, Dawei

    2016-03-11

    This paper proposes a three-dimensional inverse synthetic aperture radar (ISAR) imaging method for high-speed targets in short-range using an impulse radar. According to the requirements for high-speed target measurement in short-range, this paper establishes the single-input multiple-output (SIMO) antenna array, and further proposes a missile motion parameter estimation method based on impulse radar. By analyzing the motion geometry relationship of the warhead scattering center after translational compensation, this paper derives the receiving antenna position and the time delay after translational compensation, and thus overcomes the shortcomings of conventional translational compensation methods. By analyzing the motion characteristics of the missile, this paper estimates the missile's rotation angle and the rotation matrix by establishing a new coordinate system. Simulation results validate the performance of the proposed algorithm.

  7. Three-Dimensional ISAR Imaging Method for High-Speed Targets in Short-Range Using Impulse Radar Based on SIMO Array

    PubMed Central

    Zhou, Xinpeng; Wei, Guohua; Wu, Siliang; Wang, Dawei

    2016-01-01

    This paper proposes a three-dimensional inverse synthetic aperture radar (ISAR) imaging method for high-speed targets in short-range using an impulse radar. According to the requirements for high-speed target measurement in short-range, this paper establishes the single-input multiple-output (SIMO) antenna array, and further proposes a missile motion parameter estimation method based on impulse radar. By analyzing the motion geometry relationship of the warhead scattering center after translational compensation, this paper derives the receiving antenna position and the time delay after translational compensation, and thus overcomes the shortcomings of conventional translational compensation methods. By analyzing the motion characteristics of the missile, this paper estimates the missile’s rotation angle and the rotation matrix by establishing a new coordinate system. Simulation results validate the performance of the proposed algorithm. PMID:26978372

  8. Environmental Assessment for the Installation of New Urban Operation Complex Targets and Unmanned Aerial Vehicle Targets for the Nevada Test and Training Range

    DTIC Science & Technology

    2006-09-01

    NTTR. The proposed target areas were selected due to topographic requirements for the targets. A canyon area would provide narrow ravines and...south end of the canyon (rim level) exists through R-76. An access road would be developed that extends from the mouth of the canyon south 1.8 to...buildings to represent barracks would be placed off and along the roads. A simulated fence would cross the mouth of the canyon at the north end. The

  9. Inventory Funding Methods on Navy Ships: NWCF vs. End-use

    DTIC Science & Technology

    2013-06-01

    OPTAR Operating Target OSO Other Supply Officer POM Pre/Post-Overseas Movement R-Supply Relational Supply RoR Reorder Review SAC Service...process called other supply officer ( OSO ) transfer. Since end-use ships own their inventory, the supply officer can choose to transfer a part being...requested by another ship at their discretion, based on their ship’s anticipated requirements and their own goodwill. OSO transfers among end-use

  10. Secondary (micro-)saccades: the influence of primary saccade end point and target eccentricity on the process of postsaccadic fixation.

    PubMed

    Ohl, Sven; Brandt, Stephan A; Kliegl, Reinhold

    2011-12-08

    We examine how the size of saccadic under-/overshoot and target eccentricity influence the latency, amplitude and orientation of secondary (micro-)saccades. In our experiment, a target appeared at an eccentricity of either 6° or 14° of visual angle. Subjects were instructed to direct their gaze as quickly as possible to the target and hold fixation at the new location until the end of the trial. Typically, increasing saccadic error is associated with faster and larger secondary saccades. We show that secondary saccades at distant in contrast to close targets have in a specific error range a shorter latency, larger amplitude, and follow more often the direction of the primary saccade. Finally, we demonstrate that an undershooting primary saccade is followed almost exclusively by secondary saccades into the same direction while overshooting primary saccades are followed by secondary saccades into both directions. This supports the notion that under- and overshooting imply different consequences for postsaccadic oculomotor processing. Results are discussed using a model, introduced by Rolfs, Kliegl, and Engbert (2008), to account for the generation of microsaccades. We argue that the dynamic interplay of target eccentricity and the magnitude of the saccadic under-/overshoot can be explained by a different strength of activation in the two hemispheres of the saccadic motor map in this model. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Optimal Target Range of Closed-Loop Inspired Oxygen Support in Preterm Infants: A Randomized Cross-Over Study.

    PubMed

    van den Heuvel, Maria Elisabeth Nicoletta; van Zanten, Henriette A; Bachman, Tom E; Te Pas, Arjan B; van Kaam, Anton H; Onland, Wes

    2018-06-01

    To investigate the effect of different pulse oximetry (SpO 2 ) target range settings during automated fraction of inspired oxygen control (A-FiO 2 ) on time spent within a clinically set SpO 2 alarm range in oxygen-dependent infants on noninvasive respiratory support. Forty-one preterm infants (gestational age [median] 26 weeks, age [median] 21 days) on FiO 2  >0.21 receiving noninvasive respiratory support were subjected to A-FiO 2 using 3 SpO 2 target ranges (86%-94%, 88%-92%, or 89%-91%) in random order for 24 hours each. Before switching to the next target range, SpO 2 was manually controlled for 24 hours (washout period). The primary outcome was the time spent within the clinically set alarm limits of 86%-94%. The percent time within the 86%-94% SpO 2 alarm range was similar for all 3 A-FiO 2 target ranges (74%). Time spent in hyperoxemia was not significantly different between target ranges. However, the time spent in severe hypoxemia (SpO 2  <80%) was significantly reduced during the narrowed target ranges of A-FiO 2 (88%-92%; 1.9%, 89%-91%; 1.7%) compared with the wide target range (86%-94%; 3.4%, P < .001). There were no differences between the 88%-92% and 89-91% target range. Narrowing the target range of A-FiO 2 to the desired median ±2% is effective in reducing the time spent in hypoxemia, without increasing the risk of hyperoxemia. www.trialregister.nl: NTR4368. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Distal end side-to-side anastomoses of sequential vein graft to small target coronary arteries improve intraoperative graft flow

    PubMed Central

    2014-01-01

    Background End-to-side anastomoses to connect the distal end of the great saphenous vein (GSV) to small target coronary arteries are commonly performed in sequential coronary artery bypass grafting (CABG). However, the oversize diameter ratio between the GSV and small target vessels at end-to-side anastomoses might induce adverse hemodynamic condition. The purpose of this study was to describe a distal end side-to-side anastomosis technique and retrospectively compare the effect of distal end side-to-side versus end-to-side anastomosis on graft flow characteristics. Methods We performed side-to-side anastomoses to connect the distal end of the GSV to small target vessels on 30 patients undergoing off-pump sequential CABG in our hospital between October 2012 and July 2013. Among the 30 patients, end-to-side anastomoses at the distal end of the GSV were initially performed on 14 patients; however, due to poor graft flow, those anastomoses were revised into side-to-side anastomoses. We retrospectively compared the intraoperative graft flow characteristics of the end-to-side versus side-to-side anastomoses in the 14 patients. The patient outcomes were also evaluated. Results We found that the side-to-side anastomosis reconstruction improved intraoperative flow and reduced pulsatility index in all the 14 patients significantly. The 16 patients who had the distal end side-to-side anastomoses performed directly also exhibited satisfactory intraoperative graft flow. Three-month postoperative outcomes for all the patients were satisfactory. Conclusions Side-to-side anastomosis at the distal end of sequential vein grafts might be a promising strategy to connect small target coronary arteries to the GSV. PMID:24884776

  13. Engineered Cpf1 variants with altered PAM specificities increase genome targeting range

    PubMed Central

    Gao, Linyi; Cox, David B.T.; Yan, Winston X.; Manteiga, John C.; Schneider, Martin W.; Yamano, Takashi; Nishimasu, Hiroshi; Nureki, Osamu; Crosetto, Nicola; Zhang, Feng

    2017-01-01

    The RNA-guided endonuclease Cpf1 is a promising tool for genome editing in eukaryotic cells1–7. However, the utility of the commonly used Acidaminococcus sp. BV3L6 Cpf1 (AsCpf1) and Lachnospiraceae bacterium ND2006 Cpf1 (LbCpf1) is limited by their requirement of a TTTV protospacer adjacent motif (PAM) in the DNA substrate. To address this limitation, we performed a structure-guided mutagenesis screen to increase the targeting range of Cpf1. We engineered two AsCpf1 variants carrying the mutations S542R/K607R and S542R/K548V/N552R, which recognize TYCV and TATV PAMs, respectively, with enhanced activities in vitro and in human cells. Genome-wide assessment of off-target activity using BLISS7 assay indicated that these variants retain high DNA targeting specificity, which we further improved by introducing an additional non-PAM-interacting mutation. Introducing the identified mutations at their corresponding positions in LbCpf1 similarly altered its PAM specificity. Together, these variants increase the targeting range of Cpf1 by approximately three-fold in human coding sequences to one cleavage site per ~11 bp. PMID:28581492

  14. Inventory Funding Methods on Navy Ships: NWCF vs. End-Use

    DTIC Science & Technology

    2013-05-30

    Category OPTAR Operating Target OSO Other Supply Officer POM Pre/Post-Overseas Movement R-Supply Relational Supply RoR Reorder Review SAC Service... OSO ) transfer. Since end-use ships own their inventory, the supply officer can choose to transfer a part being requested by another ship at their...discretion, based on their ship’s anticipated requirements and their own goodwill. OSO transfers among end-use ships do not require a transfer of OPTAR

  15. Targeted Cellular Drug Delivery using Tailored Dendritic Nanostructures

    NASA Astrophysics Data System (ADS)

    Kannan, Rangaramanujam; Kolhe, Parag; Kannan, Sujatha; Lieh-Lai, Mary

    2002-03-01

    Dendrimers and hyperbranched polymers possess highly branched architectures, with a large number of controllable, tailorble, ‘peripheral’ functionalities. Since the surface chemistry of these materials can be modified with relative ease, these materials have tremendous potential in targeted drug and gene delivery. The large number of end groups can also be tailored to create special affinity to targeted cells, and can also encapsulate drugs and deliver them in a controlled manner. We are developing tailor-modified dendritic systems for drug delivery. Synthesis, in-vitro drug loading, in-vitro drug delivery, and the targeting efficiency to the cell are being studied systematically using a wide variety of experimental tools. Polyamidoamine and Polyol dendrimers, with different generations and end-groups are studied, with drugs such as Ibuprofen and Methotrexate. Our results indicate that a large number of drug molecules can be encapsulated/attached to the dendrimers, depending on the end groups. The drug-encapsulated dendrimer is able to enter the cells rapidly and deliver the drug. Targeting strategies being explored

  16. Electro-optical detector for use in a wide mass range mass spectrometer

    NASA Technical Reports Server (NTRS)

    Giffin, Charles E. (Inventor)

    1976-01-01

    An electro-optical detector is disclosed for use in a wide mass range mass spectrometer (MS), in the latter the focal plane is at or very near the exit end of the magnetic analyzer, so that a strong magnetic field of the order of 1000G or more is present at the focal plane location. The novel detector includes a microchannel electron multiplier array (MCA) which is positioned at the focal plane to convert ion beams which are focused by the MS at the focal plane into corresponding electron beams which are then accelerated to form visual images on a conductive phosphored surface. These visual images are then converted into images on the target of a vidicon camera or the like for electronic processing. Due to the strong magnetic field at the focal plane, in one embodiment of the invention, the MCA with front and back parallel ends is placed so that its front end forms an angle of not less than several degrees, preferably on the order of 10.degree.-20.degree., with respect to the focal plane, with the center line of the front end preferably located in the focal plane. In another embodiment the MCA is wedge-shaped, with its back end at an angle of about 10.degree.-20.degree. with respect to the front end. In this embodiment the MCA is placed so that its front end is located at the focal plane.

  17. An underwater ranging system based on photoacoustic effect occurring on target surface

    NASA Astrophysics Data System (ADS)

    Ni, Kai; Hu, Kai; Li, Xinghui; Wang, Lidai; Zhou, Qian; Wang, Xiaohao

    2016-11-01

    In this paper, an underwater ranging system based on photoacoustic effect occurring on target surface is proposed. In this proposal, laser pulse generated by blue-green laser is directly incident on target surface, where the photoacoustic effect occurs and a sound source is formed. And then the sound wave which is also called photoacoustic signal is received by the ultrasonic receiver after passing through water. According to the time delay between transmitting laser and receiving photoacoustic signal, and sound velocity in water, the distance between the target and the ultrasonic receiver can be calculated. Differing from underwater range finding by only laser, this approach can avoid backscattering of laser beam, so easier to implement. Experimental system according to this principle has been constructed to verify the feasibility of this technology. The experimental results showed that a ranging accuracy of 1 mm can be effectively achieved when the target is close to the ultrasonic receiver.

  18. Ends-in Vs. Ends-Out Recombination in Yeast

    PubMed Central

    Hastings, P. J.; McGill, C.; Shafer, B.; Strathern, J. N.

    1993-01-01

    Integration of linearized plasmids into yeast chromosomes has been used as a model system for the study of recombination initiated by double-strand breaks. The linearized plasmid DNA recombines efficiently into sequences homologous to the ends of the DNA. This efficient recombination occurs both for the configuration in which the break is in a contiguous region of homology (herein called the ends-in configuration) and for ``omega'' insertions in which plasmid sequences interrupt a linear region of homology (herein called the ends-out configuration). The requirements for integration of these two configurations are expected to be different. We compared these two processes in a yeast strain containing an ends-in target and an ends-out target for the same cut plasmid. Recovery of ends-in events exceeds ends-out events by two- to threefold. Possible causes for the origin of this small bias are discussed. The lack of an extreme difference in frequency implies that cooperativity between the two ends does not contribute to the efficiency with which cut circular plasmids are integrated. This may also be true for the repair of chromosomal double-strand breaks. PMID:8307337

  19. The application and research of the multi-receiving telescopes technology in laser ranging to space targets

    NASA Astrophysics Data System (ADS)

    Wu, Zhibo; Zhang, Haifeng; Zhang, Zhongping; Deng, Huarong; Li, Pu; Meng, Wendong; Cheng, Zhien; Shen, Lurun; Tang, Zhenhong

    2014-11-01

    Laser ranging technology can directly measure the distance between space targets and ground stations with the highest measurement precision and will play an irreplaceable role in orbit check and calibrating microwave measurement system. The precise orbit determination and accurate catalogue of space targets can also be realized by laser ranging with multi-stations. Among space targets, most of ones are inactive targets and space debris, which should be paid the great attentions for the safety of active spacecrafts. Because of laser diffuse reflection from the surface of targets, laser ranging to space debris has the characteristics of wide coverage and weak strength of laser echoes, even though the powerful laser system is applied. In order to increase the receiving ability of laser echoes, the large aperture telescope should be adopted. As well known, some disadvantages for one set of large aperture telescope, technical development difficulty and system running and maintenance complexity, will limit its flexible applications. The multi-receiving telescopes technology in laser ranging to space targets is put forward to realize the equivalent receiving ability produced by one larger aperture telescope by way of using multi-receiving telescopes, with the advantages of flexibility and maintenance. The theoretical analysis of the feasibility and key technologies of multi-receiving telescopes technology in laser ranging to space targets are presented in this paper. The experimental measurement system based on the 60cm SLR system and 1.56m astronomical telescopes with a distance of about 50m is established to provide the platform for researching on the multi-receiving telescopes technology. The laser ranging experiments to satellites equipped with retro-reflectors are successfully performed by using the above experimental system and verify the technical feasibility to increase the ability of echo detection. And the multi-receiving telescopes technology will become a

  20. Biomass Resource Allocation among Competing End Uses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Newes, E.; Bush, B.; Inman, D.

    The Biomass Scenario Model (BSM) is a system dynamics model developed by the U.S. Department of Energy as a tool to better understand the interaction of complex policies and their potential effects on the biofuels industry in the United States. However, it does not currently have the capability to account for allocation of biomass resources among the various end uses, which limits its utilization in analysis of policies that target biomass uses outside the biofuels industry. This report provides a more holistic understanding of the dynamics surrounding the allocation of biomass among uses that include traditional use, wood pellet exports,more » bio-based products and bioproducts, biopower, and biofuels by (1) highlighting the methods used in existing models' treatments of competition for biomass resources; (2) identifying coverage and gaps in industry data regarding the competing end uses; and (3) exploring options for developing models of biomass allocation that could be integrated with the BSM to actively exchange and incorporate relevant information.« less

  1. Observation of silicon self-diffusion enhanced by the strain originated from end-of-range defects using isotope multilayers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Isoda, Taiga; Uematsu, Masashi; Itoh, Kohei M., E-mail: kitoh@appi.keio.ac.jp

    2015-09-21

    Si self-diffusion in the presence of end-of-range (EOR) defects is investigated using {sup nat}Si/{sup 28}Si isotope multilayers. The isotope multilayers were amorphized by Ge ion implantation, and then annealed at 800–950 °C. The behavior of Si self-interstitials is investigated through the {sup 30}Si self-diffusion. The experimental {sup 30}Si profiles show further enhancement of Si self-diffusion at the EOR defect region, in addition to the transient enhanced diffusion via excess Si self-interstitials by EOR defects. To explain this additional enhanced diffusion, we propose a model which takes into account enhanced diffusion by tensile strain originated from EOR defects. The calculation results basedmore » on this model have well reproduced the experimental {sup 30}Si profiles.« less

  2. Using Negotiated Joining to Construct and Fill Open-ended Roles in Elite Culinary Groups.

    PubMed

    Tan, Vaughn

    2015-03-01

    This qualitative study examines membership processes in groups operating in an uncertain environment that prevents them from fully predefining new members' roles. I describe how nine elite high-end, cutting-edge culinary groups in the U.S. and Europe, ranging from innovative restaurants to culinary R&D groups, use negotiated joining-a previously undocumented process-to systematically construct and fill these emergent, open-ended roles. I show that negotiated joining is a consistently patterned, iterative process that begins with a role that both aspirant and target group explicitly understand to be provisional. This provisional role is then jointly modified and constructed by the aspirant and target group through repeated iterations of proposition, validation through trial and evaluation, and selective integration of validated role components. The initially provisional role stabilizes and the aspirant achieves membership if enough role components are validated; otherwise the negotiated joining process is abandoned. Negotiated joining allows the aspirant and target group to learn if a mutually desirable role is likely and, if so, to construct such a role. In addition, the provisional roles in negotiated joining can support absorptive capacity by allowing novel role components to enter target groups through aspirants' efforts to construct stable roles for themselves, while the internal adjustment involved in integrating newly validated role components can have the unintended side effect of supporting adaptation by providing opportunities for the groups to use these novel role components to modify their role structure and goals to suit a changing and uncertain environment. Negotiated joining thus reveals role ambiguity's hitherto unexamined beneficial consequences and provides a foundation for a contingency theory of new-member acquisition.

  3. Using Negotiated Joining to Construct and Fill Open-ended Roles in Elite Culinary Groups

    PubMed Central

    Tan, Vaughn

    2015-01-01

    This qualitative study examines membership processes in groups operating in an uncertain environment that prevents them from fully predefining new members’ roles. I describe how nine elite high-end, cutting-edge culinary groups in the U.S. and Europe, ranging from innovative restaurants to culinary R&D groups, use negotiated joining—a previously undocumented process—to systematically construct and fill these emergent, open-ended roles. I show that negotiated joining is a consistently patterned, iterative process that begins with a role that both aspirant and target group explicitly understand to be provisional. This provisional role is then jointly modified and constructed by the aspirant and target group through repeated iterations of proposition, validation through trial and evaluation, and selective integration of validated role components. The initially provisional role stabilizes and the aspirant achieves membership if enough role components are validated; otherwise the negotiated joining process is abandoned. Negotiated joining allows the aspirant and target group to learn if a mutually desirable role is likely and, if so, to construct such a role. In addition, the provisional roles in negotiated joining can support absorptive capacity by allowing novel role components to enter target groups through aspirants’ efforts to construct stable roles for themselves, while the internal adjustment involved in integrating newly validated role components can have the unintended side effect of supporting adaptation by providing opportunities for the groups to use these novel role components to modify their role structure and goals to suit a changing and uncertain environment. Negotiated joining thus reveals role ambiguity’s hitherto unexamined beneficial consequences and provides a foundation for a contingency theory of new-member acquisition. PMID:26273105

  4. Growth Outcomes of Preterm Infants Exposed to Different Oxygen Saturation Target Ranges from Birth

    PubMed Central

    Navarrete, Cristina T.; Wrage, Lisa A.; Carlo, Waldemar A.; Walsh, Michele C.; Rich, Wade; Gantz, Marie G.; Das, Abhik; Schibler, Kurt; Newman, Nancy S.; Piazza, Anthony J.; Poindexter, Brenda B.; Shankaran, Seetha; Sánchez, Pablo J.; Morris, Brenda H.; Frantz, Ivan D.; Van Meurs, Krisa P.; Cotten, C. Michael; Ehrenkranz, Richard A.; Bell, Edward F.; Watterberg, Kristi L.; Higgins, Rosemary D.; Duara, Shahnaz

    2017-01-01

    Objective To test whether infants randomized to a lower oxygen saturation (SpO2) target range while on supplemental oxygen from birth will have better growth velocity from birth to 36 weeks postmenstrual age (PMA), and less growth failure at 36 weeks PMA and 18–22 months corrected age. Study design We evaluated a subgroup of 810 preterm infants from the Surfactant, Positive Pressure, and Oxygenation Randomized Trial, randomized at birth to lower (85–89%, n=402, GA 26 ± 1wk, BW 839 ± 186 g) or higher (91–95%, n=408, GA 26 ± 1wk, BW 840 ± 191 g) SpO2 target ranges. Anthropometric measures were obtained at birth, postnatal days 7, 14, 21, and 28; then at 32 and 36 weeks PMA, and 18–22 months corrected age. Growth velocities were estimated using the exponential method and analyzed using linear mixed models. Poor growth outcome, defined as weight < 10th percentile at 36 weeks PMA and 18–22 months corrected age, was compared across the two treatment groups using robust Poisson regression. Results Growth outcomes including growth at 36 weeks PMA and 18–22 months corrected age, as well as growth velocity were similar in the lower and higher SpO2 target groups. Conclusion Targeting different oxygen saturation ranges between 85% and 95% from birth did not impact growth velocity or reduce growth failure in preterm infants. PMID:27344218

  5. Biosonar adjustments to target range of echolocating bottlenose dolphins (Tursiops sp.) in the wild.

    PubMed

    Jensen, F H; Bejder, L; Wahlberg, M; Madsen, P T

    2009-04-01

    Toothed whales use echolocation to locate and track prey. Most knowledge of toothed whale echolocation stems from studies on trained animals, and little is known about how toothed whales regulate and use their biosonar systems in the wild. Recent research suggests that an automatic gain control mechanism in delphinid biosonars adjusts the biosonar output to the one-way transmission loss to the target, possibly a consequence of pneumatic restrictions in how fast the sound generator can be actuated and still maintain high outputs. This study examines the relationships between target range (R), click intervals, and source levels of wild bottlenose dolphins (Tursiops sp.) by recording regular (non-buzz) echolocation clicks with a linear hydrophone array. Dolphins clicked faster with decreasing distance to the array, reflecting a decreasing delay between the outgoing echolocation click and the returning array echo. However, for interclick intervals longer than 30-40 ms, source levels were not limited by the repetition rate. Thus, pneumatic constraints in the sound-production apparatus cannot account for source level adjustments to range as a possible automatic gain control mechanism for target ranges longer than a few body lengths of the dolphin. Source level estimates drop with reducing range between the echolocating dolphins and the target as a function of 17 log(R). This may indicate either (1) an active form of time-varying gain in the biosonar independent of click intervals or (2) a bias in array recordings towards a 20 log(R) relationship for apparent source levels introduced by a threshold on received click levels included in the analysis.

  6. Differences in end-range lumbar flexion during slumped sitting and forward bending between low back pain subgroups and genders

    PubMed Central

    Hoffman, Shannon L.; Johnson, Molly B.; Zou, Dequan; Van Dillen, Linda R.

    2012-01-01

    Patterns of lumbar posture and motion are associated with low back pain (LBP). Research suggests LBP subgroups demonstrate different patterns during common tasks. This study assessed differences in end-range lumbar flexion during two tasks between two LBP subgroups classified according to the Movement System Impairment model. Additionally, the impact of gender differences on subgroup differences was assessed. Kinematic data were collected. Subjects in the Rotation (Rot) and Rotation with Extension (RotExt) LBP subgroups were asked to sit slumped and bend forward from standing. Lumbar end-range flexion was calculated. Subjects reported symptom behavior during each test. Compared to the RotExt subgroup, the Rot subgroup demonstrated greater end-range lumbar flexion during slumped sitting and a trend towards greater end-range lumbar flexion with forward bending. Compared to females, males demonstrated greater end-range lumbar flexion during slumped sitting and forward bending. A greater proportion of people in the Rot subgroup reported symptoms with each test compared to the RotExt subgroup. Males and females were equally likely to report symptoms with each test. Gender differences were not responsible for LBP subgroup differences. Subgrouping people with LBP provides insight into differences in lumbar motion within the LBP population. Results suggesting potential consistent differences across flexion-related tasks support the presence of stereotypical movement patterns that are related to LBP. PMID:22261650

  7. Dolphin "packet" use during long-range echolocation tasks.

    PubMed

    Finneran, James J

    2013-03-01

    When echolocating, dolphins typically emit a single broadband "click," then wait to receive the echo before emitting another click. However, previous studies have shown that during long-range echolocation tasks, they may instead emit a burst, or "packet," of several clicks, then wait for the packet of echoes to return before emitting another packet of clicks. The reasons for the use of packets are unknown. In this study, packet use was examined by having trained bottlenose dolphins perform long-range echolocation tasks. The tasks featured "phantom" echoes produced by capturing the dolphin's outgoing echolocation clicks, convolving the clicks with an impulse response to create an echo waveform, and then broadcasting the delayed, scaled echo to the dolphin. Dolphins were trained to report the presence of phantom echoes or a change in phantom echoes. Target range varied from 25 to 800 m. At ranges below 75 m, the dolphins rarely used packets. As the range increased beyond 75 m, two of the three dolphins increasingly produced packets, while the third dolphin instead utilized very high click repetition rates. The use of click packets appeared to be governed more by echo delay (target range) than echo amplitude.

  8. A target development program for beamhole spallation neutron sources in the megawatt range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, G.S.; Atchison, F.

    1995-10-01

    Spallation sources as an alternative to fission neutron sources have been operating successfully up to 160 kW of beam power. With the next generation of these facilities aiming at the medium power range between 0.5 and 5 MW, loads on the targets will be high enough to make present experience of little relevance. With the 0.6 MW continuous facility SINQ under construction, and a 5 MW pulsed facility (ESS) under study in Europe, a research and development program is about to be started which aimes at assessing the limits of stationary and moving solid targets and the feasibility and potentialmore » benefits of flowing liquid metal targets. Apart from theoretical work and examination of existing irradiated material, including used targets from ISIS, it is intended to take advantage of the SINQ solid rod target design to improve the relevant data base by building the target in such a way that individual rods can be equipped as irradiation capsules.« less

  9. Flexible End2End Workflow Automation of Hit-Discovery Research.

    PubMed

    Holzmüller-Laue, Silke; Göde, Bernd; Thurow, Kerstin

    2014-08-01

    The article considers a new approach of more complex laboratory automation at the workflow layer. The authors purpose the automation of end2end workflows. The combination of all relevant subprocesses-whether automated or manually performed, independently, and in which organizational unit-results in end2end processes that include all result dependencies. The end2end approach focuses on not only the classical experiments in synthesis or screening, but also on auxiliary processes such as the production and storage of chemicals, cell culturing, and maintenance as well as preparatory activities and analyses of experiments. Furthermore, the connection of control flow and data flow in the same process model leads to reducing of effort of the data transfer between the involved systems, including the necessary data transformations. This end2end laboratory automation can be realized effectively with the modern methods of business process management (BPM). This approach is based on a new standardization of the process-modeling notation Business Process Model and Notation 2.0. In drug discovery, several scientific disciplines act together with manifold modern methods, technologies, and a wide range of automated instruments for the discovery and design of target-based drugs. The article discusses the novel BPM-based automation concept with an implemented example of a high-throughput screening of previously synthesized compound libraries. © 2014 Society for Laboratory Automation and Screening.

  10. A systematic review of evidence for end-of-life communication interventions: Who do they target, how are they structured and do they work?

    PubMed

    Walczak, Adam; Butow, Phyllis N; Bu, Stella; Clayton, Josephine M

    2016-01-01

    To identify and synthesise evidence for interventions targeting end-of-life communication. Database, reference list and author searches were conducted to identify evaluations of end-of-life communication-focussed interventions. Data were extracted, synthesised and QUALSYST quality analyses were performed. Forty-five studies met inclusion criteria. Interventions targeted patients (n=6), caregivers (n=3), healthcare professionals (HCPs n=24) and multiple stakeholders (n=12). Interventions took various forms including communication skills training, education, advance care planning and structured practice changes. Substantial heterogeneity in study designs, outcomes, settings and measures was apparent and study quality was variable. A substantial number of end-of-life communication interventions have been evaluated. Interventions have particularly targeted HCPs in cancer settings, though patient, caregiver and multi-focal interventions have also been evaluated. While some interventions were efficacious in well-designed RCTs, most evidence was from less robust studies. While additional interventions targeting patients and caregivers are needed, multi-focal interventions may more effectively remove barriers to end-of-life communication. Despite the limitations evident in the existing literature, healthcare professionals may still derive useful insights into effective approaches to end-of-life communication if appropriate caution is exercised. However, additional RCTs, implementation studies and cost-benefit analyses are required to bolster arguments for implementing and resourcing communication interventions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Detection of Fast Moving and Accelerating Targets Compensating Range and Doppler Migration

    DTIC Science & Technology

    2014-06-01

    Radon -Fourier transform has been introduced to realize long- term coherent integration of the moving targets with range migration [8, 9]. Radon ...2010) Long-time coherent integration for radar target detection base on Radon -Fourier transform, in Proceedings of the IEEE Radar Conference, pp...432–436. 9. Xu, J., Yu, J., Peng, Y. & Xia, X. (2011) Radon -Fourier transform for radar target detection, I: Generalized Doppler filter bank, IEEE

  12. Real-time multi-target ranging based on chaotic polarization laser radars in the drive-response VCSELs.

    PubMed

    Zhong, Dongzhou; Xu, Geliang; Luo, Wei; Xiao, Zhenzhen

    2017-09-04

    According to the principle of complete chaos synchronization and the theory of Hilbert phase transformation, we propose a novel real-time multi-target ranging scheme by using chaotic polarization laser radar in the drive-response vertical-cavity surface-emitting lasers (VCSELs). In the scheme, to ensure each polarization component (PC) of the master VCSEL (MVCSEL) to be synchronized steadily with that of the slave VCSEL, the output x-PC and y-PC from the MVCSEL in the drive system and those in the response system are modulated by the linear electro-optic effect simultaneously. Under this condition, by simulating the influences of some key parameters of the system on the synchronization quality and the relative errors of the two-target ranging, related operating parameters can be optimized. The x-PC and the y-PC, as two chaotic radar sources, are used to implement the real-time ranging for two targets. It is found that the measured distances of the two targets at arbitrary position exhibit strong real-time stability and only slight jitter. Their resolutions are up to millimeters, and their relative errors are very small and less than 2.7%.

  13. Generation and Inheritance of Targeted Mutations in Potato (Solanum tuberosum L.) Using the CRISPR/Cas System

    PubMed Central

    Butler, Nathaniel M.; Atkins, Paul A.; Voytas, Daniel F.; Douches, David S.

    2015-01-01

    Genome editing using sequence-specific nucleases (SSNs) offers an alternative approach to conventional genetic engineering and an opportunity to extend the benefits of genetic engineering in agriculture. Currently available SSN platforms, such as zinc finger nucleases (ZFNs), transcription activator-like effector nucleases (TALENs), and CRISPR/Cas (clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated systems (Cas)) have been used in a range of plant species for targeted mutagenesis via non-homologous end joining (NHEJ) are just beginning to be explored in crops such as potato (Solanum tuberosum Group Tuberosum L.). In this study, CRISPR/Cas reagents expressing one of two single-guide RNA (sgRNA) targeting the potato ACETOLACTATE SYNTHASE1 (StALS1) gene were tested for inducing targeted mutations in callus and stable events of diploid and tetraploid potato using Agrobacterium-mediated transformation with either a conventional T-DNA or a modified geminivirus T-DNA. The percentage of primary events with targeted mutations ranged from 3–60% per transformation and from 0–29% above an expected threshold based on the number of ALS alleles. Primary events with targeted mutation frequencies above the expected threshold were used for mutation cloning and inheritance studies using clonal propagation and crosses or selfing. Four of the nine primary events used for mutation cloning had more than one mutation type, and eight primary events contained targeted mutations that were maintained across clonal generations. Somatic mutations were most evident in the diploid background with three of the four primary events having more than two mutation types at a single ALS locus. Conversely, in the tetraploid background, four of the five candidates carried only one mutation type. Single targeted mutations were inherited through the germline of both diploid and tetraploid primary events with transmission percentages ranging from 87–100%. This

  14. Generation and Inheritance of Targeted Mutations in Potato (Solanum tuberosum L.) Using the CRISPR/Cas System.

    PubMed

    Butler, Nathaniel M; Atkins, Paul A; Voytas, Daniel F; Douches, David S

    2015-01-01

    Genome editing using sequence-specific nucleases (SSNs) offers an alternative approach to conventional genetic engineering and an opportunity to extend the benefits of genetic engineering in agriculture. Currently available SSN platforms, such as zinc finger nucleases (ZFNs), transcription activator-like effector nucleases (TALENs), and CRISPR/Cas (clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated systems (Cas)) have been used in a range of plant species for targeted mutagenesis via non-homologous end joining (NHEJ) are just beginning to be explored in crops such as potato (Solanum tuberosum Group Tuberosum L.). In this study, CRISPR/Cas reagents expressing one of two single-guide RNA (sgRNA) targeting the potato ACETOLACTATE SYNTHASE1 (StALS1) gene were tested for inducing targeted mutations in callus and stable events of diploid and tetraploid potato using Agrobacterium-mediated transformation with either a conventional T-DNA or a modified geminivirus T-DNA. The percentage of primary events with targeted mutations ranged from 3-60% per transformation and from 0-29% above an expected threshold based on the number of ALS alleles. Primary events with targeted mutation frequencies above the expected threshold were used for mutation cloning and inheritance studies using clonal propagation and crosses or selfing. Four of the nine primary events used for mutation cloning had more than one mutation type, and eight primary events contained targeted mutations that were maintained across clonal generations. Somatic mutations were most evident in the diploid background with three of the four primary events having more than two mutation types at a single ALS locus. Conversely, in the tetraploid background, four of the five candidates carried only one mutation type. Single targeted mutations were inherited through the germline of both diploid and tetraploid primary events with transmission percentages ranging from 87-100%. This demonstration

  15. 2.5 Gbit/s Optical Receiver Front-End Circuit with High Sensitivity and Wide Dynamic Range

    NASA Astrophysics Data System (ADS)

    Zhu, Tiezhu; Mo, Taishan; Ye, Tianchun

    2017-12-01

    An optical receiver front-end circuit is designed for passive optical network and fabricated in a 0.18 um CMOS technology. The whole circuit consists of a transimpedance amplifier (TIA), a single-ended to differential amplifier and an output driver. The TIA employs a cascode stage as the input stage and auxiliary amplifier to reduce the miller effect. Current injecting technique is employed to enlarge the input transistor's transconductance, optimize the noise performance and overcome the lack of voltage headroom. To achieve a wide dynamic range, an automatic gain control circuit with self-adaptive function is proposed. Experiment results show an optical sensitivity of -28 dBm for a bit error rate of 10-10 at 2.5 Gbit/s and a maxim input optical power of 2 dBm using an external photodiode. The chip occupies an area of 1×0.9 mm2 and consumes around 30 mW from single 1.8 V supply. The front-end circuit can be used in various optical receivers.

  16. A novel monoclonal antibody targeting carboxymethyllysine, an advanced glycation end product in atherosclerosis and pancreatic cancer.

    PubMed

    Wendel, Ulrika; Persson, Nina; Risinger, Christian; Bengtsson, Eva; Nodin, Björn; Danielsson, Lena; Welinder, Charlotte; Nordin Fredrikson, Gunilla; Jansson, Bo; Blixt, Ola

    2018-01-01

    Advanced glycation end products are formed by non-enzymatic reactions between proteins and carbohydrates, causing irreversible lysine and arginine alterations that severely affect protein structure and function. The resulting modifications induce inflammation by binding to scavenger receptors. An increase in advanced glycation end products is observed in a number of diseases e.g. atherosclerosis and cancer. Since advanced glycation end products also are present in healthy individuals, their detection and quantification are of great importance for usage as potential biomarkers. Current methods for advanced glycation end product detection are though limited and solely measure total glycation. This study describes a new epitope-mapped single chain variable fragment, D1-B2, against carboxymethyllysine, produced from a phage library that was constructed from mouse immunizations. The phage library was selected against advanced glycation end product targets using a phage display platform. Characterization of its binding pattern was performed using large synthetic glycated peptide and protein libraries displayed on microarray slides. D1-B2 showed a preference for an aspartic acid, three positions N-terminally from a carboxymethyllysine residue and also bound to a broad collection of glycated proteins. Positive immunohistochemical staining of mouse atherosclerotic plaques and of a tissue microarray of human pancreatic tumors confirmed the usability of the new scFv for advanced glycation end product detection in tissues. This study demonstrates a promising methodology for high-throughput generation of epitope-mapped monoclonal antibodies against AGE.

  17. A novel monoclonal antibody targeting carboxymethyllysine, an advanced glycation end product in atherosclerosis and pancreatic cancer

    PubMed Central

    Wendel, Ulrika; Persson, Nina; Risinger, Christian; Bengtsson, Eva; Nodin, Björn; Danielsson, Lena; Welinder, Charlotte; Nordin Fredrikson, Gunilla

    2018-01-01

    Advanced glycation end products are formed by non-enzymatic reactions between proteins and carbohydrates, causing irreversible lysine and arginine alterations that severely affect protein structure and function. The resulting modifications induce inflammation by binding to scavenger receptors. An increase in advanced glycation end products is observed in a number of diseases e.g. atherosclerosis and cancer. Since advanced glycation end products also are present in healthy individuals, their detection and quantification are of great importance for usage as potential biomarkers. Current methods for advanced glycation end product detection are though limited and solely measure total glycation. This study describes a new epitope-mapped single chain variable fragment, D1-B2, against carboxymethyllysine, produced from a phage library that was constructed from mouse immunizations. The phage library was selected against advanced glycation end product targets using a phage display platform. Characterization of its binding pattern was performed using large synthetic glycated peptide and protein libraries displayed on microarray slides. D1-B2 showed a preference for an aspartic acid, three positions N-terminally from a carboxymethyllysine residue and also bound to a broad collection of glycated proteins. Positive immunohistochemical staining of mouse atherosclerotic plaques and of a tissue microarray of human pancreatic tumors confirmed the usability of the new scFv for advanced glycation end product detection in tissues. This study demonstrates a promising methodology for high-throughput generation of epitope-mapped monoclonal antibodies against AGE. PMID:29420566

  18. Please Ask Gently: Using Culturally Targeted Communication Strategies to Initiate End-of-Life Care Discussions With Older Chinese Americans.

    PubMed

    Chi, Han-Lin; Cataldo, Janine; Ho, Evelyn Y; Rehm, Roberta S

    2018-01-01

    Health-care providers (HCPs) find facilitating end-of-life (EOL) care discussions challenging, especially with patients whose ethnicities differ from their own. Currently, there is little guidance on how to initiate and facilitate such discussions with older Chinese Americans (≥55 years) and their families. To explore communication strategies for HCPs to initiate EOL care discussions with older Chinese Americans in the San Francisco Bay Area. This qualitative (focused) ethnographic study included field observations and individual semistructured interviews with 14 community-dwelling older Chinese Americans who lived independently at home, 9 adult children, and 7 HCPs. Responses were analyzed using open coding, memos, and comparison across participants. The study participants emphasized the importance of assessing readiness for early EOL care discussions. All recommended using indirect communication approaches to determine older Chinese Americans' readiness. Indirect communication can be culturally targeted and applied at both system-wide (ie, health-care system) and individual (ie, HCP) levels. To institutionalize the practice, health-care facilities should implement EOL care discussion inquiries as part of routine during check-in or intake questionnaires. In individual practice, using depersonalized communication strategies to initiate the discussion was recommended to determine older Chinese Americans' readiness. Assessing readiness should be an essential and necessary action for early EOL care discussions. Culturally targeted assessment of older Chinese Americans includes using indirect communication approaches to initiate an EOL care discussion to determine their readiness. In addition to health-care system integration, providers should implement and evaluate proposed EOL discussion initiation prompts with their older Chinese American patients.

  19. Geographic range did not confer resilience to extinction in terrestrial vertebrates at the end-Triassic crisis.

    PubMed

    Dunhill, Alexander M; Wills, Matthew A

    2015-08-11

    Rates of extinction vary greatly through geological time, with losses particularly concentrated in mass extinctions. Species duration at other times varies greatly, but the reasons for this are unclear. Geographical range correlates with lineage duration amongst marine invertebrates, but it is less clear how far this generality extends to other groups in other habitats. It is also unclear whether a wide geographical distribution makes groups more likely to survive mass extinctions. Here we test for extinction selectivity amongst terrestrial vertebrates across the end-Triassic event. We demonstrate that terrestrial vertebrate clades with larger geographical ranges were more resilient to extinction than those with smaller ranges throughout the Triassic and Jurassic. However, this relationship weakened with increasing proximity to the end-Triassic mass extinction, breaking down altogether across the event itself. We demonstrate that these findings are not a function of sampling biases; a perennial issue in studies of this kind.

  20. Integrated long-range UAV/UGV collaborative target tracking

    NASA Astrophysics Data System (ADS)

    Moseley, Mark B.; Grocholsky, Benjamin P.; Cheung, Carol; Singh, Sanjiv

    2009-05-01

    Coordinated operations between unmanned air and ground assets allow leveraging of multi-domain sensing and increase opportunities for improving line of sight communications. While numerous military missions would benefit from coordinated UAV-UGV operations, foundational capabilities that integrate stove-piped tactical systems and share available sensor data are required and not yet available. iRobot, AeroVironment, and Carnegie Mellon University are working together, partially SBIR-funded through ARDEC's small unit network lethality initiative, to develop collaborative capabilities for surveillance, targeting, and improved communications based on PackBot UGV and Raven UAV platforms. We integrate newly available technologies into computational, vision, and communications payloads and develop sensing algorithms to support vision-based target tracking. We first simulated and then applied onto real tactical platforms an implementation of Decentralized Data Fusion, a novel technique for fusing track estimates from PackBot and Raven platforms for a moving target in an open environment. In addition, system integration with AeroVironment's Digital Data Link onto both air and ground platforms has extended our capabilities in communications range to operate the PackBot as well as in increased video and data throughput. The system is brought together through a unified Operator Control Unit (OCU) for the PackBot and Raven that provides simultaneous waypoint navigation and traditional teleoperation. We also present several recent capability accomplishments toward PackBot-Raven coordinated operations, including single OCU display design and operation, early target track results, and Digital Data Link integration efforts, as well as our near-term capability goals.

  1. An end-to-end approach to developing biological and chemical detector requirements

    NASA Astrophysics Data System (ADS)

    Teclemariam, Nerayo P.; Purvis, Liston K.; Foltz, Greg W.; West, Todd; Edwards, Donna M.; Fruetel, Julia A.; Gleason, Nathaniel J.

    2009-05-01

    Effective defense against chemical and biological threats requires an "end-to-end" strategy that encompasses the entire problem space, from threat assessment and target hardening to response planning and recovery. A key element of the strategy is the definition of appropriate system requirements for surveillance and detection of threat agents. Our end-to-end approach to venue chem/bio defense is captured in the Facilities Weapons of Mass Destruction Decision Analysis Capability (FacDAC), an integrated system-of-systems toolset that can be used to generate requirements across all stages of detector development. For example, in the early stage of detector development the approach can be used to develop performance targets (e.g., sensitivity, selectivity, false positive rate) to provide guidance on what technologies to pursue. In the development phase, after a detector technology has been selected, the approach can aid in determining performance trade-offs and down-selection of competing technologies. During the application stage, the approach can be employed to design optimal defensive architectures that make the best use of available technology to maximize system performance. This presentation will discuss the end-to-end approach to defining detector requirements and demonstrate the capabilities of the FacDAC toolset using examples from a number of studies for the Department of Homeland Security.

  2. Vitamin K antagonist use: evidence of the difficulty of achieving and maintaining target INR range and subsequent consequences.

    PubMed

    Schein, Jeff R; White, C Michael; Nelson, Winnie W; Kluger, Jeffrey; Mearns, Elizabeth S; Coleman, Craig I

    2016-01-01

    Vitamin K antagonists (VKAs) are effective oral anticoagulants that are titrated to a narrow therapeutic international normalized ratio (INR) range. We reviewed published literature assessing the impact of INR stability - getting into and staying in target INR range - on outcomes including thrombotic events, major bleeding, and treatment costs, as well as key factors that impact INR stability. A time in therapeutic range (TTR) of ≥65 % is commonly accepted as the definition of INR stability. In the real-world setting, this is seldom achieved with standard-of-care management, thus increasing the patients' risks of thrombotic or major bleeding events. There are many factors associated with poor INR control. Being treated in community settings, newly initiated on a VKA, younger in age, or nonadherent to therapy, as well as having polymorphisms of CYP2C9 or VKORC1, or multiple physical or mental co-morbid disease states have been associated with lower TTR. Clinical prediction tools are available, though they can only explain <10 % of the variance behind poor INR control. Clinicians caring for patients who require anticoagulation are encouraged to intensify diligence in INR management when using VKAs and to consider appropriate use of newer anticoagulants as a therapeutic option.

  3. Experimental determination of particle range and dose distribution in thick targets through fragmentation reactions of stable heavy ions.

    PubMed

    Inaniwa, Taku; Kohno, Toshiyuki; Tomitani, Takehiro; Urakabe, Eriko; Sato, Shinji; Kanazawa, Mitsutaka; Kanai, Tatsuaki

    2006-09-07

    In radiation therapy with highly energetic heavy ions, the conformal irradiation of a tumour can be achieved by using their advantageous features such as the good dose localization and the high relative biological effectiveness around their mean range. For effective utilization of such properties, it is necessary to evaluate the range of incident ions and the deposited dose distribution in a patient's body. Several methods have been proposed to derive such physical quantities; one of them uses positron emitters generated through projectile fragmentation reactions of incident ions with target nuclei. We have proposed the application of the maximum likelihood estimation (MLE) method to a detected annihilation gamma-ray distribution for determination of the range of incident ions in a target and we have demonstrated the effectiveness of the method with computer simulations. In this paper, a water, a polyethylene and a polymethyl methacrylate target were each irradiated with stable (12)C, (14)N, (16)O and (20)Ne beams. Except for a few combinations of incident beams and targets, the MLE method could determine the range of incident ions R(MLE) with a difference between R(MLE) and the experimental range of less than 2.0 mm under the circumstance that the measurement of annihilation gamma rays was started just after the irradiation of 61.4 s and lasted for 500 s. In the process of evaluating the range of incident ions with the MLE method, we must calculate many physical quantities such as the fluence and the energy of both primary ions and fragments as a function of depth in a target. Consequently, by using them we can obtain the dose distribution. Thus, when the mean range of incident ions is determined with the MLE method, the annihilation gamma-ray distribution and the deposited dose distribution can be derived simultaneously. The derived dose distributions in water for the mono-energetic heavy-ion beams of four species were compared with those measured with an

  4. Helmet-mounted displays in long-range-target visual acquisition

    NASA Astrophysics Data System (ADS)

    Wilkins, Donald F.

    1999-07-01

    Aircrews have always sought a tactical advantage within the visual range (WVR) arena -- usually defined as 'see the opponent first.' Even with radar and interrogation foe/friend (IFF) systems, the pilot who visually acquires his opponent first has a significant advantage. The Helmet Mounted Cueing System (HMCS) equipped with a camera offers an opportunity to correct the problems with the previous approaches. By utilizing real-time image enhancement technique and feeding the image to the pilot on the HMD, the target can be visually acquired well beyond the range provided by the unaided eye. This paper will explore the camera and display requirements for such a system and place those requirements within the context of other requirements, such as weight.

  5. Multi-dimensional position sensor using range detectors

    DOEpatents

    Vann, Charles S.

    2000-01-01

    A small, non-contact optical sensor uses ranges and images to detect its relative position to an object in up to six degrees of freedom. The sensor has three light emitting range detectors which illuminate a target and can be used to determine distance and two tilt angles. A camera located between the three range detectors senses the three remaining degrees of freedom, two translations and one rotation. Various range detectors, with different light sources, e.g. lasers and LEDs, different collection options, and different detection schemes, e.g. diminishing return and time of flight can be used. This sensor increases the capability and flexibility of computer controlled machines, e.g. it can instruct a robot how to adjust automatically to different positions and orientations of a part.

  6. Non-Cooperative Target Recognition by Means of Singular Value Decomposition Applied to Radar High Resolution Range Profiles †

    PubMed Central

    López-Rodríguez, Patricia; Escot-Bocanegra, David; Fernández-Recio, Raúl; Bravo, Ignacio

    2015-01-01

    Radar high resolution range profiles are widely used among the target recognition community for the detection and identification of flying targets. In this paper, singular value decomposition is applied to extract the relevant information and to model each aircraft as a subspace. The identification algorithm is based on angle between subspaces and takes place in a transformed domain. In order to have a wide database of radar signatures and evaluate the performance, simulated range profiles are used as the recognition database while the test samples comprise data of actual range profiles collected in a measurement campaign. Thanks to the modeling of aircraft as subspaces only the valuable information of each target is used in the recognition process. Thus, one of the main advantages of using singular value decomposition, is that it helps to overcome the notable dissimilarities found in the shape and signal-to-noise ratio between actual and simulated profiles due to their difference in nature. Despite these differences, the recognition rates obtained with the algorithm are quite promising. PMID:25551484

  7. Simple Monitoring of Gene Targeting Efficiency in Human Somatic Cell Lines Using the PIGA Gene

    PubMed Central

    Karnan, Sivasundaram; Konishi, Yuko; Ota, Akinobu; Takahashi, Miyuki; Damdindorj, Lkhagvasuren; Hosokawa, Yoshitaka; Konishi, Hiroyuki

    2012-01-01

    Gene targeting in most of human somatic cell lines has been labor-intensive because of low homologous recombination efficiency. The development of an experimental system that permits a facile evaluation of gene targeting efficiency in human somatic cell lines is the first step towards the improvement of this technology and its application to a broad range of cell lines. In this study, we utilized phosphatidylinositol glycan anchor biosynthesis class A (PIGA), a gene essential for the synthesis of glycosylphosphatidyl inositol (GPI) anchors, as a reporter of gene targeting events in human somatic cell lines. Targeted disruption of PIGA was quantitatively detected with FLAER, a reagent that specifically binds to GPI anchors. Using this PIGA-based reporter system, we successfully detected adeno-associated virus (AAV)-mediated gene targeting events both with and without promoter-trap enrichment of gene-targeted cell population. The PIGA-based reporter system was also capable of reproducing previous findings that an AAV-mediated gene targeting achieves a remarkably higher ratio of homologous versus random integration (H/R ratio) of targeting vectors than a plasmid-mediated gene targeting. The PIGA-based system also detected an approximately 2-fold increase in the H/R ratio achieved by a small negative selection cassette introduced at the end of the AAV-based targeting vector with a promoter-trap system. Thus, our PIGA-based system is useful for monitoring AAV-mediated gene targeting and will assist in improving gene targeting technology in human somatic cell lines. PMID:23056640

  8. Object Tracking and Target Reacquisition Based on 3-D Range Data for Moving Vehicles

    PubMed Central

    Lee, Jehoon; Lankton, Shawn; Tannenbaum, Allen

    2013-01-01

    In this paper, we propose an approach for tracking an object of interest based on 3-D range data. We employ particle filtering and active contours to simultaneously estimate the global motion of the object and its local deformations. The proposed algorithm takes advantage of range information to deal with the challenging (but common) situation in which the tracked object disappears from the image domain entirely and reappears later. To cope with this problem, a method based on principle component analysis (PCA) of shape information is proposed. In the proposed method, if the target disappears out of frame, shape similarity energy is used to detect target candidates that match a template shape learned online from previously observed frames. Thus, we require no a priori knowledge of the target’s shape. Experimental results show the practical applicability and robustness of the proposed algorithm in realistic tracking scenarios. PMID:21486717

  9. Robust Fusion of Color and Depth Data for RGB-D Target Tracking Using Adaptive Range-Invariant Depth Models and Spatio-Temporal Consistency Constraints.

    PubMed

    Xiao, Jingjing; Stolkin, Rustam; Gao, Yuqing; Leonardis, Ales

    2017-09-06

    This paper presents a novel robust method for single target tracking in RGB-D images, and also contributes a substantial new benchmark dataset for evaluating RGB-D trackers. While a target object's color distribution is reasonably motion-invariant, this is not true for the target's depth distribution, which continually varies as the target moves relative to the camera. It is therefore nontrivial to design target models which can fully exploit (potentially very rich) depth information for target tracking. For this reason, much of the previous RGB-D literature relies on color information for tracking, while exploiting depth information only for occlusion reasoning. In contrast, we propose an adaptive range-invariant target depth model, and show how both depth and color information can be fully and adaptively fused during the search for the target in each new RGB-D image. We introduce a new, hierarchical, two-layered target model (comprising local and global models) which uses spatio-temporal consistency constraints to achieve stable and robust on-the-fly target relearning. In the global layer, multiple features, derived from both color and depth data, are adaptively fused to find a candidate target region. In ambiguous frames, where one or more features disagree, this global candidate region is further decomposed into smaller local candidate regions for matching to local-layer models of small target parts. We also note that conventional use of depth data, for occlusion reasoning, can easily trigger false occlusion detections when the target moves rapidly toward the camera. To overcome this problem, we show how combining target information with contextual information enables the target's depth constraint to be relaxed. Our adaptively relaxed depth constraints can robustly accommodate large and rapid target motion in the depth direction, while still enabling the use of depth data for highly accurate reasoning about occlusions. For evaluation, we introduce a new RGB

  10. Tritium target manufacturing for use in accelerators

    NASA Astrophysics Data System (ADS)

    Bach, P.; Monnin, C.; Van Rompay, M.; Ballanger, A.

    2001-07-01

    As a neutron tube manufacturer, SODERN is now in charge of manufacturing tritium targets for accelerators, in cooperation with CEA/DAM/DTMN in Valduc. Specific deuterium and tritium targets are manufactured on request, according to the requirements of the users, starting from titanium target on copper substrate, and going to more sophisticated devices. A wide range of possible uses is covered, including thin targets for neutron calibration, thick targets with controlled loading of deuterium and tritium, rotating targets for higher lifetimes, or large size rotating targets for accelerators used in boron neutron therapy. Activity of targets lies in the 1 to 1000 Curie, diameter of targets being up to 30 cm. Special targets are also considered, including surface layer targets for lowering tritium desorption under irradiation, or those made from different kinds of occluders such as titanium, zirconium, erbium, scandium, with different substrates. It is then possible to optimize either neutron output, or lifetime and stability, or thermal behavior.

  11. Targeting of the Fun30 nucleosome remodeller by the Dpb11 scaffold facilitates cell cycle-regulated DNA end resection

    PubMed Central

    Bantele, Susanne CS; Ferreira, Pedro; Gritenaite, Dalia; Boos, Dominik; Pfander, Boris

    2017-01-01

    DNA double strand breaks (DSBs) can be repaired by either recombination-based or direct ligation-based mechanisms. Pathway choice is made at the level of DNA end resection, a nucleolytic processing step, which primes DSBs for repair by recombination. Resection is thus under cell cycle control, but additionally regulated by chromatin and nucleosome remodellers. Here, we show that both layers of control converge in the regulation of resection by the evolutionarily conserved Fun30/SMARCAD1 remodeller. Budding yeast Fun30 and human SMARCAD1 are cell cycle-regulated by interaction with the DSB-localized scaffold protein Dpb11/TOPBP1, respectively. In yeast, this protein assembly additionally comprises the 9-1-1 damage sensor, is involved in localizing Fun30 to damaged chromatin, and thus is required for efficient long-range resection of DSBs. Notably, artificial targeting of Fun30 to DSBs is sufficient to bypass the cell cycle regulation of long-range resection, indicating that chromatin remodelling during resection is underlying DSB repair pathway choice. DOI: http://dx.doi.org/10.7554/eLife.21687.001 PMID:28063255

  12. Tests of Gravity Using Lunar Laser Ranging.

    PubMed

    Merkowitz, Stephen M

    2010-01-01

    Lunar laser ranging (LLR) has been a workhorse for testing general relativity over the past four decades. The three retroreflector arrays put on the Moon by the Apollo astronauts and the French built arrays on the Soviet Lunokhod rovers continue to be useful targets, and have provided the most stringent tests of the Strong Equivalence Principle and the time variation of Newton's gravitational constant. The relatively new ranging system at the Apache Point 3.5 meter telescope now routinely makes millimeter level range measurements. Incredibly, it has taken 40 years for ground station technology to advance to the point where characteristics of the lunar retroreflectors are limiting the precision of the range measurements. In this article, we review the gravitational science and technology of lunar laser ranging and discuss prospects for the future.

  13. Tests of gravity Using Lunar Laser Ranging

    NASA Technical Reports Server (NTRS)

    Merkowitz, Stephen M.

    2010-01-01

    Lunar laser ranging (LLR) has been a workhorse for testing general relativity over the pat four decades. The three retrorefiector arrays put on the Moon by the Apollo astronauts and the French built array on the second Soviet Lunokhod rover continue to be useful targets, and have provided the most stringent tests of the Strong Equivalence Principle and the time variation of Newton's gravitational constant. The relatively new ranging system at the Apache Point :3.5 meter telescope now routinely makes millimeter level range measurements. Incredibly. it has taken 40 years for ground station technology to advance to the point where characteristics of the lunar retrorefiectors are limiting the precision of the range measurements. In this article. we review the gravitational science and technology of lunar laser ranging and discuss prospects for the future.

  14. In vitro validation and reliability study of electromagnetic skin sensors for evaluation of end range of motion positions of the hip.

    PubMed

    Audenaert, E A; Vigneron, L; Van Hoof, T; D'Herde, K; van Maele, G; Oosterlinck, D; Pattyn, C

    2011-12-01

    There is growing evidence that femoroacetabular impingement (FAI) is a probable risk factor for the development of early osteoarthritis in the nondysplastic hip. As FAI arises with end range of motion activities, measurement errors related to skin movement might be higher than anticipated when using previously reported methods for kinematic evaluation of the hip. We performed an in vitro validation and reliability study of a noninvasive method to define pelvic and femur positions in end range of motion activities of the hip using an electromagnetic tracking device. Motion data, collected from sensors attached to the bone and skin of 11 cadaver hips, were simultaneously obtained and compared in a global reference frame. Motion data were then transposed in the hip joint local coordinate systems. Observer-related variability in locating the anatomical landmarks required to define the local coordinate system and variability of determining the hip joint center was evaluated. Angular root mean square (RMS) differences between the bony and skin sensors averaged 3.2° (SD 3.5°) and 1.8° (SD 2.3°) in the global reference frame for the femur and pelvic sensors, respectively. Angular RMS differences between the bony and skin sensors in the hip joint local coordinate systems ranged at end range of motion and dependent on the motion under investigation from 1.91 to 5.81°. The presented protocol for evaluation of hip motion seems to be suited for the 3-D description of motion relevant to the experimental and clinical evaluation of femoroacetabular impingement.

  15. Using Nurse Ratings of Physician Communication in the ICU To Identify Potential Targets for Interventions To Improve End-of-Life Care.

    PubMed

    Ramos, Kathleen J; Downey, Lois; Nielsen, Elizabeth L; Treece, Patsy D; Shannon, Sarah E; Curtis, J Randall; Engelberg, Ruth A

    2016-03-01

    Communication among doctors, nurses, and families contributes to high-quality end-of-life care, but is difficult to improve. Our objective was to identify aspects of communication appropriate for interventions to improve quality of dying in the intensive care unit (ICU). This observational study used data from a cluster-randomized trial of an interdisciplinary intervention to improve end-of-life care at 15 Seattle/Tacoma area hospitals (2003-2008). Nurses completed surveys for patients dying in the ICU. We examined associations between nurse-assessed predictors (physician-nurse communication, physician-family communication) and nurse ratings of patients' quality of dying (nurse-QODD-1). Based on 1173 nurse surveys, four of six physician-nurse communication topics were positively associated with nurse-QODD-1: family questions, family dynamics, spiritual/religious issues, and cultural issues. Discussions between nurses and physicians about nurses' concerns for patients or families were negatively associated. All physician-family communication ratings, as assessed by nurses, were positively associated with nurse-QODD-1: answering family's questions, listening to family, asking about treatments patient would want, helping family decide patient's treatment wishes, and overall communication. Path analysis suggested overall physician-family communication and helping family incorporate patient's wishes were directly associated with nurse-QODD-1. Several topics of physician-nurse communication, as rated by nurses, were associated with higher nurse-rated quality of dying, whereas one topic, nurses' concerns for patient or family, was associated with poorer ratings. Higher nurse ratings of physician-family communication were uniformly associated with higher quality of dying, highlighting the importance of this communication. Physician support of family decision making was particularly important, suggesting a potential target for interventions to improve end-of-life care.

  16. The effect of targeted wide age range SIAs in reducing measles incidence in the African Region.

    PubMed

    Masresha, Balcha; Luce, Richard; Katsande, Regis; Fall, Amadou; Eshetu, Meseret; Mihigo, Richard

    2017-01-01

    Periodic measles supplemental immunisation activities (SIAs) increase population immunity and thereby reduce the pool of accumulated susceptible children. They are typically conducted every 2 - 4 years, and most often target children up to five years of age. Between 2012 and 2015, after surveillance data indicated a shift in the epidemiological profile of measles towards older age groups, 11 countries were supported to conduct wide age range SIAs based on their local epidemiological patterns. Six other countries conducted SIAs with measles-rubella vaccines targeting ages 9 months to 14 years as an initial step of introducing rubella vaccine into the immunization program. In subsequent years, the incidence of confirmed measles dropped significantly in 13 of the 17 countries reviewed. The findings emphasize the importance of well-functioning surveillance systems, and the benefits of using of surveillance data to determine the specific target age-range for periodic SIAs to accelerate progress towards measles elimination.

  17. The effect of targeted wide age range SIAs in reducing measles incidence in the African Region

    PubMed Central

    Masresha, Balcha; Luce, Richard; Katsande, Regis; Fall, Amadou; Eshetu, Meseret; Mihigo, Richard

    2017-01-01

    Periodic measles supplemental immunisation activities (SIAs) increase population immunity and thereby reduce the pool of accumulated susceptible children. They are typically conducted every 2 – 4 years, and most often target children up to five years of age. Between 2012 and 2015, after surveillance data indicated a shift in the epidemiological profile of measles towards older age groups, 11 countries were supported to conduct wide age range SIAs based on their local epidemiological patterns. Six other countries conducted SIAs with measles-rubella vaccines targeting ages 9 months to 14 years as an initial step of introducing rubella vaccine into the immunization program. In subsequent years, the incidence of confirmed measles dropped significantly in 13 of the 17 countries reviewed. The findings emphasize the importance of well-functioning surveillance systems, and the benefits of using of surveillance data to determine the specific target age-range for periodic SIAs to accelerate progress towards measles elimination. PMID:29296148

  18. Controlling range expansion in habitat networks by adaptively targeting source populations.

    PubMed

    Hock, Karlo; Wolff, Nicholas H; Beeden, Roger; Hoey, Jessica; Condie, Scott A; Anthony, Kenneth R N; Possingham, Hugh P; Mumby, Peter J

    2016-08-01

    Controlling the spread of invasive species, pests, and pathogens is often logistically limited to interventions that target specific locations at specific periods. However, in complex, highly connected systems, such as marine environments connected by ocean currents, populations spread dynamically in both space and time via transient connectivity links. This results in nondeterministic future distributions of species in which local populations emerge dynamically and concurrently over a large area. The challenge, therefore, is to choose intervention locations that will maximize the effectiveness of the control efforts. We propose a novel method to manage dynamic species invasions and outbreaks that identifies the intervention locations most likely to curtail population expansion by selectively targeting local populations most likely to expand their future range. Critically, at any point during the development of the invasion or outbreak, the method identifies the local intervention that maximizes the long-term benefit across the ecosystem by restricting species' potential to spread. In so doing, the method adaptively selects the intervention targets under dynamically changing circumstances. To illustrate the effectiveness of the method we applied it to controlling the spread of crown-of-thorns starfish (Acanthaster sp.) outbreaks across Australia's Great Barrier Reef. Application of our method resulted in an 18-fold relative improvement in management outcomes compared with a random targeting of reefs in putative starfish control scenarios. Although we focused on applying the method to reducing the spread of an unwanted species, it can also be used to facilitate the spread of desirable species through connectivity networks. For example, the method could be used to select those fragments of habitat most likely to rebuild a population if they were sufficiently well protected. © 2016 Society for Conservation Biology.

  19. Searching the optimal PTH target range in children undergoing peritoneal dialysis: new insights from international cohort studies.

    PubMed

    Haffner, Dieter; Schaefer, Franz

    2013-04-01

    The treatment of the mineral and bone disorder associated with chronic kidney disease (CKD-MBD) remains a major challenge in pediatric patients. The principal aims of therapeutic measures are not only to prevent the debilitating skeletal complications and to achieve normal growth but also to preserve long-term cardiovascular health. Serum parathyroid hormone (PTH) levels are used as a surrogate parameter of bone turnover. Whereas it is generally accepted that serum calcium and phosphate levels should be kept within the range for age, current pediatric consensus guidelines differ markedly with respect to the optimal PTH target range and operate on a limited evidence base. Recently, the International Pediatric Dialysis Network (IPPN) established a global registry collecting detailed clinical and biochemical information, including data relevant to CKD-MBD in children on chronic peritoneal dialysis (PD). This review highlights the current evidence basis regarding the optimal PTH target range in pediatric CKD patients, and re-assesses the current guidelines in view of the outcome data collected by the IPPN registry. Based on a comprehensive evaluation of CKD-MBD outcome measures in this global patient cohort, a PTH target range of 1.7-3 times the upper limit of normal (i.e. 100-200 pg/ml) appears reasonable in children undergoing chronic PD.

  20. Synthetic Scene Generation of the Stennis V and V Target Range for the Calibration of Remote Sensing Systems

    NASA Technical Reports Server (NTRS)

    Cao, Chang-Yong; Blonski, Slawomir; Ryan, Robert; Gasser, Jerry; Zanoni, Vicki

    1999-01-01

    The verification and validation (V&V) target range developed at Stennis Space Center is a useful test site for the calibration of remote sensing systems. In this paper, we present a simple algorithm for generating synthetic radiance scenes or digital models of this target range. The radiation propagation for the target in the solar reflective and thermal infrared spectral regions is modeled using the atmospheric radiative transfer code MODTRAN 4. The at-sensor, in-band radiance and spectral radiance for a given sensor at a given altitude is predicted. Software is developed to generate scenes with different spatial and spectral resolutions using the simulated at-sensor radiance values. The radiometric accuracy of the simulation is evaluated by comparing simulated with AVIRIS acquired radiance values. The results show that in general there is a good match between AVIRIS sensor measured and MODTRAN predicted radiance values for the target despite the fact that some anomalies exist. Synthetic scenes provide a cost-effective way for in-flight validation of the spatial and radiometric accuracy of the data. Other applications include mission planning, sensor simulation, and trade-off analysis in sensor design.

  1. Comparative Effectiveness of Targeted Prostate Biopsy Using Magnetic Resonance Imaging Ultrasound Fusion Software and Visual Targeting: a Prospective Study.

    PubMed

    Lee, Daniel J; Recabal, Pedro; Sjoberg, Daniel D; Thong, Alan; Lee, Justin K; Eastham, James A; Scardino, Peter T; Vargas, Hebert Alberto; Coleman, Jonathan; Ehdaie, Behfar

    2016-09-01

    We compared the diagnostic outcomes of magnetic resonance-ultrasound fusion and visually targeted biopsy for targeting regions of interest on prostate multiparametric magnetic resonance imaging. Patients presenting for prostate biopsy with regions of interest on multiparametric magnetic resonance imaging underwent magnetic resonance imaging targeted biopsy. For each region of interest 2 visually targeted cores were obtained, followed by 2 cores using a magnetic resonance-ultrasound fusion device. Our primary end point was the difference in the detection of high grade (Gleason 7 or greater) and any grade cancer between visually targeted and magnetic resonance-ultrasound fusion, investigated using McNemar's method. Secondary end points were the difference in detection rate by biopsy location using a logistic regression model and the difference in median cancer length using the Wilcoxon signed rank test. We identified 396 regions of interest in 286 men. The difference in the detection of high grade cancer between magnetic resonance-ultrasound fusion biopsy and visually targeted biopsy was -1.4% (95% CI -6.4 to 3.6, p=0.6) and for any grade cancer the difference was 3.5% (95% CI -1.9 to 8.9, p=0.2). Median cancer length detected by magnetic resonance-ultrasound fusion and visually targeted biopsy was 5.5 vs 5.8 mm, respectively (p=0.8). Magnetic resonance-ultrasound fusion biopsy detected 15% more cancers in the transition zone (p=0.046) and visually targeted biopsy detected 11% more high grade cancer at the prostate base (p=0.005). Only 52% of all high grade cancers were detected by both techniques. We found no evidence of a significant difference in the detection of high grade or any grade cancer between visually targeted and magnetic resonance-ultrasound fusion biopsy. However, the performance of each technique varied in specific biopsy locations and the outcomes of both techniques were complementary. Combining visually targeted biopsy and magnetic resonance

  2. Using Nurse Ratings of Physician Communication in the ICU To Identify Potential Targets for Interventions To Improve End-of-Life Care

    PubMed Central

    Downey, Lois; Nielsen, Elizabeth L.; Treece, Patsy D.; Shannon, Sarah E.; Curtis, J. Randall; Engelberg, Ruth A.

    2016-01-01

    Abstract Background: Communication among doctors, nurses, and families contributes to high-quality end-of-life care, but is difficult to improve. Objective: Our objective was to identify aspects of communication appropriate for interventions to improve quality of dying in the intensive care unit (ICU). Methods: This observational study used data from a cluster-randomized trial of an interdisciplinary intervention to improve end-of-life care at 15 Seattle/Tacoma area hospitals (2003–2008). Nurses completed surveys for patients dying in the ICU. We examined associations between nurse-assessed predictors (physician-nurse communication, physician-family communication) and nurse ratings of patients' quality of dying (nurse-QODD-1). Results: Based on 1173 nurse surveys, four of six physician-nurse communication topics were positively associated with nurse-QODD-1: family questions, family dynamics, spiritual/religious issues, and cultural issues. Discussions between nurses and physicians about nurses' concerns for patients or families were negatively associated. All physician-family communication ratings, as assessed by nurses, were positively associated with nurse-QODD-1: answering family's questions, listening to family, asking about treatments patient would want, helping family decide patient's treatment wishes, and overall communication. Path analysis suggested overall physician-family communication and helping family incorporate patient's wishes were directly associated with nurse-QODD-1. Conclusions: Several topics of physician-nurse communication, as rated by nurses, were associated with higher nurse-rated quality of dying, whereas one topic, nurses' concerns for patient or family, was associated with poorer ratings. Higher nurse ratings of physician-family communication were uniformly associated with higher quality of dying, highlighting the importance of this communication. Physician support of family decision making was particularly important, suggesting a

  3. Vision for action and perception elicit dissociable adherence to Weber's law across a range of 'graspable' target objects.

    PubMed

    Heath, Matthew; Manzone, Joseph; Khan, Michaela; Davarpanah Jazi, Shirin

    2017-10-01

    A number of studies have reported that grasps and manual estimations of differently sized target objects (e.g., 20 through 70 mm) violate and adhere to Weber's law, respectively (e.g., Ganel et al. 2008a, Curr Biol 18:R599-R601)-a result interpreted as evidence that separate visual codes support actions (i.e., absolute) and perceptions (i.e., relative). More recent work employing a broader range of target objects (i.e., 5 through 120 mm) has laid question to this claim and proposed that grasps for 'larger' target objects (i.e., >20 mm) elicit an inverse relationship to Weber's law and that manual estimations for target objects greater than 40 mm violate the law (Bruno et al. 2016, Neuropsychologia 91:327-334). In accounting for this finding, it was proposed that biomechanical limits in aperture shaping preclude the application of Weber's law for larger target objects. It is, however, important to note that the work supporting a biomechanical account may have employed target objects that approached -or were beyond-some participants' maximal aperture separation. The present investigation examined whether grasps and manual estimations differentially adhere to Weber's law across a continuous range of functionally 'graspable' target objects (i.e., 10,…,80% of participant-specific maximal aperture separation). In addition, we employed a method of adjustment task to examine whether manual estimation provides a valid proxy for a traditional measure of perceptual judgment. Manual estimation and method of adjustment tasks demonstrated adherence to Weber's law across the continuous range of target objects used here, whereas grasps violated the law. Thus, results evince that grasps and manual estimations of graspable target objects are, respectively, mediated via absolute and relative visual information.

  4. Frequency-Modulated, Continuous-Wave Laser Ranging Using Photon-Counting Detectors

    NASA Technical Reports Server (NTRS)

    Erkmen, Baris I.; Barber, Zeb W.; Dahl, Jason

    2014-01-01

    Optical ranging is a problem of estimating the round-trip flight time of a phase- or amplitude-modulated optical beam that reflects off of a target. Frequency- modulated, continuous-wave (FMCW) ranging systems obtain this estimate by performing an interferometric measurement between a local frequency- modulated laser beam and a delayed copy returning from the target. The range estimate is formed by mixing the target-return field with the local reference field on a beamsplitter and detecting the resultant beat modulation. In conventional FMCW ranging, the source modulation is linear in instantaneous frequency, the reference-arm field has many more photons than the target-return field, and the time-of-flight estimate is generated by balanced difference- detection of the beamsplitter output, followed by a frequency-domain peak search. This work focused on determining the maximum-likelihood (ML) estimation algorithm when continuous-time photoncounting detectors are used. It is founded on a rigorous statistical characterization of the (random) photoelectron emission times as a function of the incident optical field, including the deleterious effects caused by dark current and dead time. These statistics enable derivation of the Cramér-Rao lower bound (CRB) on the accuracy of FMCW ranging, and derivation of the ML estimator, whose performance approaches this bound at high photon flux. The estimation algorithm was developed, and its optimality properties were shown in simulation. Experimental data show that it performs better than the conventional estimation algorithms used. The demonstrated improvement is a factor of 1.414 over frequency-domainbased estimation. If the target interrogating photons and the local reference field photons are costed equally, the optimal allocation of photons between these two arms is to have them equally distributed. This is different than the state of the art, in which the local field is stronger than the target return. The optimal

  5. LIQUID TARGET

    DOEpatents

    Martin, M.D.; Salsig, W.W. Jr.

    1959-01-13

    A liquid handling apparatus is presented for a liquid material which is to be irradiated. The apparatus consists essentially of a reservoir for the liquid, a target element, a drain tank and a drain lock chamber. The target is in the form of a looped tube, the upper end of which is adapted to be disposed in a beam of atomic particles. The lower end of the target tube is in communication with the liquid in the reservoir and a means is provided to continuously circulate the liquid material to be irradiated through the target tube. Means to heat the reservoir tank is provided in the event that a metal is to be used as the target material. The apparatus is provided with suitable valves and shielding to provide maximum safety in operation.

  6. Use of a plastic insulin dosage guide to correct blood glucose levels out of the target range and for carbohydrate counting in subjects with type 1 diabetes.

    PubMed

    Kaufman, F R; Halvorson, M; Carpenter, S

    1999-08-01

    To improve glycemic control, a hand-held plastic Insulin Dosage Guide was developed to correct blood glucose levels outside of the target range. Protocol 1: Some 40 children (mean age 10.6+/-4.6 years) were randomly assigned for 3 months to use a written-on-paper algorithm or the Insulin Dosage Guide to correct abnormal blood glucose levels. Mean HbA1c and blood glucose levels and time to teach insulin dosage correction were compared. Protocol 2: The Insulin Dosage Guide was used by 83 subjects (mean age 11.4+/-4.3 years) for 1 year, and mean HbA1c levels, blood glucose levels, and number of consecutive high blood glucose values taken before and after the year were compared. Protocol 3: Some 20 patients (mean age 10.1+/-3.7 years) using rapid-acting insulin and 64 patients (mean age 15.9+/-3.6 years) using an insulin pump and rapid-acting insulin used the Insulin Dosage Guide and had mean blood glucose levels, HbA1c, and percentage of blood glucose levels outside of the target range determined. Protocol 1: There was a significant reduction in mean HbA1c (P = 0.04) and blood glucose levels (P = 0.05) and in the time needed to teach how to correct blood glucose values using the Insulin Dosage Guide compared with the paper algorithm. Protocol 2: There was a decrease in mean HbA1c levels (P = 0.0001) and a decrease in the mean number of consecutive blood glucose levels (P = 0.001) over the 1-year time period. Protocol 3: With rapid-acting insulin, there was a significant increase in the percentage of blood glucose levels within the target range (1 month, P = 0.04; at 3 months, P = 0.03). With the insulin pump, there was a high rate (90%) of blood glucose levels in the target range during pump initiation when the Insulin Dosage Guide was used. This inexpensive hand-held plastic card, which is portable and easy to use, may help patients improve glycemia and successfully manage diabetes.

  7. Active laser ranging with frequency transfer using frequency comb

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Hongyuan; Wei, Haoyun; Yang, Honglei

    2016-05-02

    A comb-based active laser ranging scheme is proposed for enhanced distance resolution and a common time standard for the entire system. Three frequency combs with different repetition rates are used as light sources at the two ends where the distance is measured. Pulse positions are determined through asynchronous optical sampling and type II second harmonic generation. Results show that the system achieves a maximum residual of 379.6 nm and a standard deviation of 92.9 nm with 2000 averages over 23.6 m. Moreover, as for the frequency transfer, an atom clock and an adjustable signal generator, synchronized to the atom clock, are used asmore » time standards for the two ends to appraise the frequency deviation introduced by the proposed system. The system achieves a residual fractional deviation of 1.3 × 10{sup −16} for 1 s, allowing precise frequency transfer between the two clocks at the two ends.« less

  8. Tool use and the distalization of the end-effector

    PubMed Central

    Bonaiuto, James B.; Jacobs, Stéphane; Frey, Scott H.

    2009-01-01

    We review recent neurophysiological data from macaques and humans suggesting that the use of tools extends the internal representation of the actor’s hand, and relate it to our modeling of the visual control of grasping. We introduce the idea that, in addition to extending the body schema to incorporate the tool, tool use involves distalization of the end-effector from hand to tool. Different tools extend the body schema in different ways, with a displaced visual target and a novel, task-specific processing of haptic feedback to the hand. This distalization is critical in order to exploit the unique functional capacities engendered by complex tools. PMID:19347356

  9. Targeted next-generation sequencing at copy-number breakpoints for personalized analysis of rearranged ends in solid tumors.

    PubMed

    Kim, Hyun-Kyoung; Park, Won Cheol; Lee, Kwang Man; Hwang, Hai-Li; Park, Seong-Yeol; Sorn, Sungbin; Chandra, Vishal; Kim, Kwang Gi; Yoon, Woong-Bae; Bae, Joon Seol; Shin, Hyoung Doo; Shin, Jong-Yeon; Seoh, Ju-Young; Kim, Jong-Il; Hong, Kyeong-Man

    2014-01-01

    The concept of the utilization of rearranged ends for development of personalized biomarkers has attracted much attention owing to its clinical applicability. Although targeted next-generation sequencing (NGS) for recurrent rearrangements has been successful in hematologic malignancies, its application to solid tumors is problematic due to the paucity of recurrent translocations. However, copy-number breakpoints (CNBs), which are abundant in solid tumors, can be utilized for identification of rearranged ends. As a proof of concept, we performed targeted next-generation sequencing at copy-number breakpoints (TNGS-CNB) in nine colon cancer cases including seven primary cancers and two cell lines, COLO205 and SW620. For deduction of CNBs, we developed a novel competitive single-nucleotide polymorphism (cSNP) microarray method entailing CNB-region refinement by competitor DNA. Using TNGS-CNB, 19 specific rearrangements out of 91 CNBs (20.9%) were identified, and two polymerase chain reaction (PCR)-amplifiable rearrangements were obtained in six cases (66.7%). And significantly, TNGS-CNB, with its high positive identification rate (82.6%) of PCR-amplifiable rearrangements at candidate sites (19/23), just from filtering of aligned sequences, requires little effort for validation. Our results indicate that TNGS-CNB, with its utility for identification of rearrangements in solid tumors, can be successfully applied in the clinical laboratory for cancer-relapse and therapy-response monitoring.

  10. Defining an end state for CO2 sequestration and EOR in North America

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Friedmann, S J

    2006-04-20

    CO{sub 2} capture and storage (CCS) presents a challenge to long-range planners, economic interests, regulators, law-makers, and other stakeholders and decision makers. To improve and optimize the use of limited resources and finances, it is important to define an end state for CCS. This ends state should be defined around desired goals and reasonable timelines for execution. While this definition may have substantial technology, policy or economic implications, it need not be prescriptive in terms of technology pathway, policy mechanism, or economic targets. To illustrate these concerns, this paper will present a credible vision of what an end state formore » North American might look like. From that, examples of key investment and planning decisions are provided to illustrate the value of end-state characterization.« less

  11. NDCX-II target experiments and simulations

    DOE PAGES

    Barnard, J. J.; More, R. M.; Terry, M.; ...

    2013-06-13

    The ion accelerator NDCX-II is undergoing commissioning at Lawrence Berkeley National Laboratory (LBNL). Its principal mission is to explore ion-driven High Energy Density Physics (HEDP) relevant to Inertial Fusion Energy (IFE) especially in the Warm Dense Matter (WDM) regime. We have carried out hydrodynamic simulations of beam-heated targets for parameters expected for the initial configuration of NDCX-II. For metal foils of order one micron thick (thin targets), the beam is predicted to heat the target in a timescale comparable to the hydrodynamic expansion time for experiments that infer material properties from measurements of the resulting rarefaction wave. We have alsomore » carried out hydrodynamic simulations of beam heating of metallic foam targets several tens of microns thick (thick targets) in which the ion range is shorter than the areal density of the material. In this case shock waves will form and we derive simple scaling laws for the efficiency of conversion of ion energy into kinetic energy of fluid flow. Geometries with a tamping layer may also be used to study the merging of a tamper shock with the end-of-range shock. As a result, this process can occur in tamped, direct drive IFE targets.« less

  12. 3D range-gated super-resolution imaging based on stereo matching for moving platforms and targets

    NASA Astrophysics Data System (ADS)

    Sun, Liang; Wang, Xinwei; Zhou, Yan

    2017-11-01

    3D range-gated superresolution imaging is a novel 3D reconstruction technique for target detection and recognition with good real-time performance. However, for moving targets or platforms such as airborne, shipborne, remote operated vehicle and autonomous vehicle, 3D reconstruction has a large error or failure. In order to overcome this drawback, we propose a method of stereo matching for 3D range-gated superresolution reconstruction algorithm. In experiment, the target is a doll of Mario with a height of 38cm at the location of 34m, and we obtain two successive frame images of the Mario. To confirm our method is effective, we transform the original images with translation, rotation, scale and perspective, respectively. The experimental result shows that our method has a good result of 3D reconstruction for moving targets or platforms.

  13. Underwater single beam circumferentially scanning detection system using range-gated receiver and adaptive filter

    NASA Astrophysics Data System (ADS)

    Tan, Yayun; Zhang, He; Zha, Bingting

    2017-09-01

    Underwater target detection and ranging in seawater are of interest in unmanned underwater vehicles. This study presents an underwater detection system that synchronously scans a collimated laser beam and a narrow field of view to circumferentially detect an underwater target. Hybrid methods of range-gated and variable step-size least mean squares (VSS-LMS) adaptive filter are proposed to suppress water backscattering. The range-gated receiver eliminates the backscattering of near-field water. The VSS-LMS filter extracts the target echo in the remaining backscattering and the constant fraction discriminator timing method is used to improve ranging accuracy. The optimal constant fraction is selected by analysing the jitter noise and slope of the target echo. The prototype of the underwater detection system is constructed and tested in coastal seawater, then the effectiveness of backscattering suppression and high-ranging accuracy is verified through experimental results and analysis discussed in this paper.

  14. Evaluation of potential internal target volume of liver tumors using cine-MRI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akino, Yuichi, E-mail: akino@radonc.med.osaka-u.ac.jp; Oh, Ryoong-Jin; Masai, Norihisa

    2014-11-01

    Purpose: Four-dimensional computed tomography (4DCT) is widely used for evaluating moving tumors, including lung and liver cancers. For patients with unstable respiration, however, the 4DCT may not visualize tumor motion properly. High-speed magnetic resonance imaging (MRI) sequences (cine-MRI) permit direct visualization of respiratory motion of liver tumors without considering radiation dose exposure to patients. Here, the authors demonstrated a technique for evaluating internal target volume (ITV) with consideration of respiratory variation using cine-MRI. Methods: The authors retrospectively evaluated six patients who received stereotactic body radiotherapy (SBRT) to hepatocellular carcinoma. Before acquiring planning CT, sagittal and coronal cine-MRI images were acquiredmore » for 30 s with a frame rate of 2 frames/s. The patient immobilization was conducted under the same condition as SBRT. Planning CT images were then acquired within 15 min from cine-MRI image acquisitions, followed by a 4DCT scan. To calculate tumor motion, the motion vectors between two continuous frames of cine-MRI images were calculated for each frame using the pyramidal Lucas–Kanade method. The target contour was delineated on one frame, and each vertex of the contour was shifted and copied onto the following frame using neighboring motion vectors. 3D trajectory data were generated with the centroid of the contours on sagittal and coronal images. To evaluate the accuracy of the tracking method, the motion of clearly visible blood vessel was analyzed with the motion tracking and manual detection techniques. The target volume delineated on the 50% (end-exhale) phase of 4DCT was translated with the trajectory data, and the distribution of the occupancy probability of target volume was calculated as potential ITV (ITV {sub Potential}). The concordance between ITV {sub Potential} and ITV estimated with 4DCT (ITV {sub 4DCT}) was evaluated using the Dice’s similarity coefficient (DSC

  15. Long-range depth profiling of camouflaged targets using single-photon detection

    NASA Astrophysics Data System (ADS)

    Tobin, Rachael; Halimi, Abderrahim; McCarthy, Aongus; Ren, Ximing; McEwan, Kenneth J.; McLaughlin, Stephen; Buller, Gerald S.

    2018-03-01

    We investigate the reconstruction of depth and intensity profiles from data acquired using a custom-designed time-of-flight scanning transceiver based on the time-correlated single-photon counting technique. The system had an operational wavelength of 1550 nm and used a Peltier-cooled InGaAs/InP single-photon avalanche diode detector. Measurements were made of human figures, in plain view and obscured by camouflage netting, from a stand-off distance of 230 m in daylight using only submilliwatt average optical powers. These measurements were analyzed using a pixelwise cross correlation approach and compared to analysis using a bespoke algorithm designed for the restoration of multilayered three-dimensional light detection and ranging images. This algorithm is based on the optimization of a convex cost function composed of a data fidelity term and regularization terms, and the results obtained show that it achieves significant improvements in image quality for multidepth scenarios and for reduced acquisition times.

  16. Tracking Honey Bees Using LIDAR (Light Detection and Ranging) Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BENDER, SUSAN FAE ANN; RODACY, PHILIP J.; SCHMITT, RANDAL L.

    The Defense Advanced Research Projects Agency (DARPA) has recognized that biological and chemical toxins are a real and growing threat to troops, civilians, and the ecosystem. The Explosives Components Facility at Sandia National Laboratories (SNL) has been working with the University of Montana, the Southwest Research Institute, and other agencies to evaluate the feasibility of directing honeybees to specific targets, and for environmental sampling of biological and chemical ''agents of harm''. Recent work has focused on finding and locating buried landmines and unexploded ordnance (UXO). Tests have demonstrated that honeybees can be trained to efficiently and accurately locate explosive signaturesmore » in the environment. However, it is difficult to visually track the bees and determine precisely where the targets are located. Video equipment is not practical due to its limited resolution and range. In addition, it is often unsafe to install such equipment in a field. A technology is needed to provide investigators with the standoff capability to track bees and accurately map the location of the suspected targets. This report documents Light Detection and Ranging (LIDAR) tests that were performed by SNL. These tests have shown that a LIDAR system can be used to track honeybees. The LIDAR system can provide both the range and coordinates of the target so that the location of buried munitions can be accurately mapped for subsequent removal.« less

  17. Parallel analysis of RNA ends enhances global investigation of microRNAs and target RNAs of Brachypodium distachyon

    PubMed Central

    2013-01-01

    Background The wild grass Brachypodium distachyon has emerged as a model system for temperate grasses and biofuel plants. However, the global analysis of miRNAs, molecules known to be key for eukaryotic gene regulation, has been limited in B. distachyon to studies examining a few samples or that rely on computational predictions. Similarly an in-depth global analysis of miRNA-mediated target cleavage using parallel analysis of RNA ends (PARE) data is lacking in B. distachyon. Results B. distachyon small RNAs were cloned and deeply sequenced from 17 libraries that represent different tissues and stresses. Using a computational pipeline, we identified 116 miRNAs including not only conserved miRNAs that have not been reported in B. distachyon, but also non-conserved miRNAs that were not found in other plants. To investigate miRNA-mediated cleavage function, four PARE libraries were constructed from key tissues and sequenced to a total depth of approximately 70 million sequences. The roughly 5 million distinct genome-matched sequences that resulted represent an extensive dataset for analyzing small RNA-guided cleavage events. Analysis of the PARE and miRNA data provided experimental evidence for miRNA-mediated cleavage of 264 sites in predicted miRNA targets. In addition, PARE analysis revealed that differentially expressed miRNAs in the same family guide specific target RNA cleavage in a correspondingly tissue-preferential manner. Conclusions B. distachyon miRNAs and target RNAs were experimentally identified and analyzed. Knowledge gained from this study should provide insights into the roles of miRNAs and the regulation of their targets in B. distachyon and related plants. PMID:24367943

  18. 33 CFR 334.200 - Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air...) The regulations. (i) Through navigation of surface craft outside the target areas will be permitted at...

  19. Double 90 Degrees Counterrotated End-to-End-Anastomosis: An Experimental Study of an Intestinal Anastomosis Technique.

    PubMed

    Holzner, Philipp; Kulemann, Birte; Seifert, Gabriel; Glatz, Torben; Chikhladze, Sophia; Höppner, Jens; Hopt, Ulrich; Timme, Sylvia; Bronsert, Peter; Sick, Olivia; Zhou, Cheng; Marjanovic, Goran

    2015-06-01

    The aim of the article is to investigate a new anastomotic technique compared with standardized intestinal anastomotic procedures. A total of 32 male Wistar rats were randomized to three groups. In the Experimental Group (n = 10), the new double 90 degrees inversely rotated anastomosis was used, in the End Group (n = 10) a single-layer end-to-end anastomosis, and in the Side Group (n = 12) a single-layer side-to-side anastomosis. All anastomoses were done using interrupted sutures. On postoperative day 4, rats were relaparotomized. Bursting pressure, hydroxyproline concentration, a semiquantitative adhesion score and two histological anastomotic healing scores (mucosal healing according to Chiu and overall anastomotic healing according to Verhofstad) were collected. Most data are presented as median (range). p < 0.05 was considered significant. Anastomotic insufficiency occurred only in one rat of the Side Group. Median bursting pressure in the Experimental Group was 105 mm Hg (range = 72-161 mm Hg), significantly higher in the End Group (164 mm Hg; range = 99-210 mm Hg; p = 0.021) and lower in the Side Group by trend (81 mm Hg; range = 59-122 mm Hg; p = 0.093). Hydroxyproline concentration did not differ significantly in between the groups. The adhesion score was 2.5 (range = 1-3) in the Experimental Group, 2 (range = 1-2) in the End Group, but there were significantly more adhesions in the Side Group (range = 3-4); p = 0.020 versus Experimental Group, p < 0.001 versus End Group. The Chiu Score showed the worst mucosal healing in the Experimental Group. The overall Verhofstad Score was significantly worse (mean = 2.032; standard deviation [SD] = 0.842) p = 0.031 and p = 0.002 in the Experimental Group, compared with the Side Group (mean = 1.729; SD = 0.682) and the End Group (mean = 1.571; SD = 0.612). The new anastomotic technique is feasible and did not show any relevant complication. Even though it was superior to the side-to-side anastomosis by trend with

  20. Laser-Directed Ranging System Implementing Single Camera System for Telerobotics Applications

    NASA Technical Reports Server (NTRS)

    Wells, Dennis L. (Inventor); Li, Larry C. (Inventor); Cox, Brian J. (Inventor)

    1995-01-01

    The invention relates generally to systems for determining the range of an object from a reference point and, in one embodiment, to laser-directed ranging systems useful in telerobotics applications. Digital processing techniques are employed which minimize the complexity and cost of the hardware and software for processing range calculations, thereby enhancing the commercial attractiveness of the system for use in relatively low-cost robotic systems. The system includes a video camera for generating images of the target, image digitizing circuitry, and an associated frame grabber circuit. The circuit first captures one of the pairs of stereo video images of the target, and then captures a second video image of the target as it is partly illuminated by the light beam, suitably generated by a laser. The two video images, taken sufficiently close together in time to minimize camera and scene motion, are converted to digital images and then compared. Common pixels are eliminated, leaving only a digital image of the laser-illuminated spot on the target. Mw centroid of the laser illuminated spot is dm obtained and compared with a predetermined reference point, predetermined by design or calibration, which represents the coordinate at the focal plane of the laser illumination at infinite range. Preferably, the laser and camera are mounted on a servo-driven platform which can be oriented to direct the camera and the laser toward the target. In one embodiment the platform is positioned in response to movement of the operator's head. Position and orientation sensors are used to monitor head movement. The disparity between the digital image of the laser spot and the reference point is calculated for determining range to the target. Commercial applications for the system relate to active range-determination systems, such as those used with robotic systems in which it is necessary to determine the, range to a workpiece or object to be grasped or acted upon by a robot arm end

  1. Detecting Anomalies from End-to-End Internet Performance Measurements (PingER) Using Cluster Based Local Outlier Factor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ali, Saqib; Wang, Guojun; Cottrell, Roger Leslie

    PingER (Ping End-to-End Reporting) is a worldwide end-to-end Internet performance measurement framework. It was developed by the SLAC National Accelerator Laboratory, Stanford, USA and running from the last 20 years. It has more than 700 monitoring agents and remote sites which monitor the performance of Internet links around 170 countries of the world. At present, the size of the compressed PingER data set is about 60 GB comprising of 100,000 flat files. The data is publicly available for valuable Internet performance analyses. However, the data sets suffer from missing values and anomalies due to congestion, bottleneck links, queuing overflow, networkmore » software misconfiguration, hardware failure, cable cuts, and social upheavals. Therefore, the objective of this paper is to detect such performance drops or spikes labeled as anomalies or outliers for the PingER data set. In the proposed approach, the raw text files of the data set are transformed into a PingER dimensional model. The missing values are imputed using the k-NN algorithm. The data is partitioned into similar instances using the k-means clustering algorithm. Afterward, clustering is integrated with the Local Outlier Factor (LOF) using the Cluster Based Local Outlier Factor (CBLOF) algorithm to detect the anomalies or outliers from the PingER data. Lastly, anomalies are further analyzed to identify the time frame and location of the hosts generating the major percentage of the anomalies in the PingER data set ranging from 1998 to 2016.« less

  2. Detecting Anomalies from End-to-End Internet Performance Measurements (PingER) Using Cluster Based Local Outlier Factor

    DOE PAGES

    Ali, Saqib; Wang, Guojun; Cottrell, Roger Leslie; ...

    2018-05-28

    PingER (Ping End-to-End Reporting) is a worldwide end-to-end Internet performance measurement framework. It was developed by the SLAC National Accelerator Laboratory, Stanford, USA and running from the last 20 years. It has more than 700 monitoring agents and remote sites which monitor the performance of Internet links around 170 countries of the world. At present, the size of the compressed PingER data set is about 60 GB comprising of 100,000 flat files. The data is publicly available for valuable Internet performance analyses. However, the data sets suffer from missing values and anomalies due to congestion, bottleneck links, queuing overflow, networkmore » software misconfiguration, hardware failure, cable cuts, and social upheavals. Therefore, the objective of this paper is to detect such performance drops or spikes labeled as anomalies or outliers for the PingER data set. In the proposed approach, the raw text files of the data set are transformed into a PingER dimensional model. The missing values are imputed using the k-NN algorithm. The data is partitioned into similar instances using the k-means clustering algorithm. Afterward, clustering is integrated with the Local Outlier Factor (LOF) using the Cluster Based Local Outlier Factor (CBLOF) algorithm to detect the anomalies or outliers from the PingER data. Lastly, anomalies are further analyzed to identify the time frame and location of the hosts generating the major percentage of the anomalies in the PingER data set ranging from 1998 to 2016.« less

  3. End-to-end test of spatial accuracy in Gamma Knife treatments for trigeminal neuralgia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brezovich, Ivan A., E-mail: ibrezovich@uabmc.edu; Wu, Xingen; Duan, Jun

    2014-11-01

    Purpose: Spatial accuracy is most crucial when small targets like the trigeminal nerve are treated. Although current quality assurance procedures typically verify that individual apparatus, like the MRI scanner, CT scanner, Gamma Knife, etc., are meeting specifications, the cumulative error of all equipment and procedures combined may exceed safe margins. This study uses an end-to-end approach to assess the overall targeting errors that may have occurred in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 in.) diameter MRI-contrast filled cavity embedded within a PMMA plastic capsule. Themore » capsule is positioned within the head frame such that the location of the cavity matches the Gamma Knife coordinates of an arbitrarily chosen, previously treated patient. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pinprick to identify the cavity center. Treatments are planned for radiation delivery with 4 mm collimators according to MRI and CT scans using the clinical localizer boxes and acquisition protocols. Shots are planned so that the 50% isodose surface encompasses the cavity. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pinprick, which represents the intended target, and the centroid of the 50% isodose line, which is the center of the radiation field that was actually delivered. Results: Averaged over ten patient simulations, targeting errors along the x, y, and z coordinates (patient’s left-to-right, posterior-to-anterior, and head-to-foot) were, respectively, −0.060 ± 0.363, −0.350 ± 0.253, and 0.348 ± 0.204 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely, 0.109 ± 0.167, −0.191 ± 0.144, and 0.211 ± 0.094 mm. The largest errors along individual axes

  4. The Arabidopsis SPIRAL2 Protein Targets and Stabilizes Microtubule Minus Ends.

    PubMed

    Fan, Yuanwei; Burkart, Graham M; Dixit, Ram

    2018-03-19

    The contribution of microtubule tip dynamics to the assembly and function of plant microtubule arrays remains poorly understood. Here, we report that the Arabidopsis SPIRAL2 (SPR2) protein modulates the dynamics of the acentrosomal cortical microtubule plus and minus ends in an opposing manner. Live imaging of a functional SPR2-mRuby fusion protein revealed that SPR2 shows both microtubule plus- and minus-end tracking activity in addition to localization at microtubule intersections and along the lattice. Analysis of microtubule dynamics showed that cortical microtubule plus ends rarely undergo catastrophe in the spr2-2 knockout mutant compared to wild-type. In contrast, cortical microtubule minus ends in spr2-2 depolymerized at a much faster rate than in wild-type. Destabilization of the minus ends in spr2-2 caused a significant decrease in the lifetime of microtubule crossovers, which dramatically reduced the microtubule-severing frequency and inhibited light-induced microtubule array reorientation. Using in vitro reconstitution experiments combined with single-molecule imaging, we found that recombinant SPR2-GFP intrinsically localizes to microtubule minus ends, where it binds stably and inhibits their dynamics. Together, our data establish SPR2 as a new type of microtubule tip regulator that governs the length and lifetime of microtubules. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Moving target detection in flash mode against stroboscopic mode by active range-gated laser imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Xuanyu; Wang, Xinwei; Sun, Liang; Fan, Songtao; Lei, Pingshun; Zhou, Yan; Liu, Yuliang

    2018-01-01

    Moving target detection is important for the application of target tracking and remote surveillance in active range-gated laser imaging. This technique has two operation modes based on the difference of the number of pulses per frame: stroboscopic mode with the accumulation of multiple laser pulses per frame and flash mode with a single shot of laser pulse per frame. In this paper, we have established a range-gated laser imaging system. In the system, two types of lasers with different frequency were chosen for the two modes. Electric fan and horizontal sliding track were selected as the moving targets to compare the moving blurring between two modes. Consequently, the system working in flash mode shows more excellent performance in motion blurring against stroboscopic mode. Furthermore, based on experiments and theoretical analysis, we presented the higher signal-to-noise ratio of image acquired by stroboscopic mode than flash mode in indoor and underwater environment.

  6. Integrated approach for automatic target recognition using a network of collaborative sensors.

    PubMed

    Mahalanobis, Abhijit; Van Nevel, Alan

    2006-10-01

    We introduce what is believed to be a novel concept by which several sensors with automatic target recognition (ATR) capability collaborate to recognize objects. Such an approach would be suitable for netted systems in which the sensors and platforms can coordinate to optimize end-to-end performance. We use correlation filtering techniques to facilitate the development of the concept, although other ATR algorithms may be easily substituted. Essentially, a self-configuring geometry of netted platforms is proposed that positions the sensors optimally with respect to each other, and takes into account the interactions among the sensor, the recognition algorithms, and the classes of the objects to be recognized. We show how such a paradigm optimizes overall performance, and illustrate the collaborative ATR scheme for recognizing targets in synthetic aperture radar imagery by using viewing position as a sensor parameter.

  7. Receptor for advanced glycation end products is targeted by FBXO10 for ubiquitination and degradation.

    PubMed

    Evankovich, John; Lear, Travis; Mckelvey, Alison; Dunn, Sarah; Londino, James; Liu, Yuan; Chen, Bill B; Mallampalli, Rama K

    2017-09-01

    The receptor for advanced glycation end products (RAGE) is a highly expressed cell membrane receptor serving to anchor lung epithelia to matrix components, and it also amplifies inflammatory signaling during acute lung injury. However, mechanisms that regulate its protein concentrations in cells remain largely unknown. Here we show that RAGE exhibits an extended life span in lung epithelia ( t ½ 6 h), is monoubiquitinated at K374, and is degraded in lysosomes. The RAGE ligand ODN2006, a synthetic oligodeoxynucleotide resembling pathogenic hypomethylated CpG DNA, promotes rapid lysosomal RAGE degradation through activation of protein kinase Cζ (PKCζ), which phosphorylates RAGE. PKCζ overexpression enhances RAGE degradation, while PKCζ knockdown stabilizes RAGE protein levels and prevents ODN2006-mediated degradation. We identify that RAGE is targeted by the ubiquitin E3 ligase subunit F-box protein O10 (FBXO10), which associates with RAGE to mediate its ubiquitination and degradation. FBXO10 depletion in cells stabilizes RAGE and is required for ODN2006-mediated degradation. These data suggest that modulation of regulators involved in ubiquitin-mediated disposal of RAGE might serve as unique molecular inputs directing RAGE cellular concentrations and downstream responses, which are critical in an array of inflammatory disorders, including acute lung injury.-Evankovich, J., Lear, T., Mckelvey, A., Dunn, S., Londino, J., Liu, Y., Chen, B. B., Mallampalli, R. K. Receptor for advanced glycation end products is targeted by FBXO10 for ubiquitination and degradation. © FASEB.

  8. A chemostratigraphic method to determine the end of impact-related sedimentation at marine-target impact craters (Chesapeake Bay, Lockne, Tvären)

    USGS Publications Warehouse

    Ormö, Jens; Hill, Andrew C.; Self-Trail, Jean M.

    2010-01-01

    To better understand the impact cratering process and its environmental consequences at the local to global scale, it is important to know when in the geological record of an impact crater the impact-related processes cease. In many instances, this occurs with the end of early crater modification, leaving an obvious sedimentological boundary between impactites and secular sediments. However, in marine-target craters the transition from early crater collapse (i.e., water resurge) to postimpact sedimentation can appear gradual. With the a priori assumption that the reworked target materials of the resurge deposits have a different chemical composition to the secular sediments we use chemostratigraphy (δ13Ccarb, %Corg, major elements) of sediments from the Chesapeake Bay, Lockne, and Tvären craters, to define this boundary. We show that the end of impact-related sedimentation in these cases is fairly rapid, and does not necessarily coincide with a visual boundary (e.g., grain size shift). Therefore, in some cases, the boundary is more precisely determined by chemostratigraphy, especially carbonate carbon isotope variations, rather than by visual inspection. It is also shown how chemostratigraphy can confirm the age of marine-target craters that were previously determined by biostratigraphy; by comparing postimpact carbon isotope trends with established regional trends.

  9. Global Maps of ProQ Binding In Vivo Reveal Target Recognition via RNA Structure and Stability Control at mRNA 3' Ends.

    PubMed

    Holmqvist, Erik; Li, Lei; Bischler, Thorsten; Barquist, Lars; Vogel, Jörg

    2018-05-15

    The conserved RNA-binding protein ProQ has emerged as the centerpiece of a previously unknown third large network of post-transcriptional control in enterobacteria. Here, we have used in vivo UV crosslinking and RNA sequencing (CLIP-seq) to map hundreds of ProQ binding sites in Salmonella enterica and Escherichia coli. Our analysis of these binding sites, many of which are conserved, suggests that ProQ recognizes its cellular targets through RNA structural motifs found in small RNAs (sRNAs) and at the 3' end of mRNAs. Using the cspE mRNA as a model for 3' end targeting, we reveal a function for ProQ in protecting mRNA against exoribonucleolytic activity. Taken together, our results underpin the notion that ProQ governs a post-transcriptional network distinct from those of the well-characterized sRNA-binding proteins, CsrA and Hfq, and suggest a previously unrecognized, sRNA-independent role of ProQ in stabilizing mRNAs. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Fast range estimation based on active range-gated imaging for coastal surveillance

    NASA Astrophysics Data System (ADS)

    Kong, Qingshan; Cao, Yinan; Wang, Xinwei; Tong, Youwan; Zhou, Yan; Liu, Yuliang

    2012-11-01

    Coastal surveillance is very important because it is useful for search and rescue, illegal immigration, or harbor security and so on. Furthermore, range estimation is critical for precisely detecting the target. Range-gated laser imaging sensor is suitable for high accuracy range especially in night and no moonlight. Generally, before detecting the target, it is necessary to change delay time till the target is captured. There are two operating mode for range-gated imaging sensor, one is passive imaging mode, and the other is gate viewing mode. Firstly, the sensor is passive mode, only capturing scenes by ICCD, once the object appears in the range of monitoring area, we can obtain the course range of the target according to the imaging geometry/projecting transform. Then, the sensor is gate viewing mode, applying micro second laser pulses and sensor gate width, we can get the range of targets by at least two continuous images with trapezoid-shaped range intensity profile. This technique enables super-resolution depth mapping with a reduction of imaging data processing. Based on the first step, we can calculate the rough value and quickly fix delay time which the target is detected. This technique has overcome the depth resolution limitation for 3D active imaging and enables super-resolution depth mapping with a reduction of imaging data processing. By the two steps, we can quickly obtain the distance between the object and sensor.

  11. Extreme soil acidity from biodegradable trap and skeet targets increases severity of pollution at shooting ranges.

    PubMed

    McTee, Michael R; Mummey, Daniel L; Ramsey, Philip W; Hinman, Nancy W

    2016-01-01

    Lead pollution at shooting ranges overshadows the potential for contamination issues from trap and skeet targets. We studied the environmental influence of targets sold as biodegradable by determining the components of the targets and sampling soils at a former sporting clay range. Targets comprised approximately 53% CaCO3, 41% S(0), and 6% modifiers, and on a molar basis, there was 2.3 times more S(0) than CaCO3. We observed a positive correlation between target cover and SO4(2-) (ρ=0.82, P<0.001), which indicated the oxidation of S(0) to H2SO4. Sulfate was negatively correlated with pH (ρ=-0.93, P<0.001) because insufficient CaCO3 existed in the targets to neutralize all the acid produced from S(0) oxidation. Plant cover decreased with decreasing soil pH (ρ=0.62, P=0.006). For sites that had pH values below 3, 24tons of lime per 1000tons of soil would be required to raise soil pH to 6.5. Lime-facilitated pH increases would be transitory because S(0) would continue to oxidize to H2SO4 until the S(0) is depleted. This study demonstrates that biodegradable trap and skeet targets can acidify soil, which has implications for increasing the mobility of Pb from shotgun pellets. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Genetically targeted 3D visualisation of Drosophila neurons under Electron Microscopy and X-Ray Microscopy using miniSOG

    PubMed Central

    Ng, Julian; Browning, Alyssa; Lechner, Lorenz; Terada, Masako; Howard, Gillian; Jefferis, Gregory S. X. E.

    2016-01-01

    Large dimension, high-resolution imaging is important for neural circuit visualisation as neurons have both long- and short-range patterns: from axons and dendrites to the numerous synapses at terminal endings. Electron Microscopy (EM) is the favoured approach for synaptic resolution imaging but how such structures can be segmented from high-density images within large volume datasets remains challenging. Fluorescent probes are widely used to localise synapses, identify cell-types and in tracing studies. The equivalent EM approach would benefit visualising such labelled structures from within sub-cellular, cellular, tissue and neuroanatomical contexts. Here we developed genetically-encoded, electron-dense markers using miniSOG. We demonstrate their ability in 1) labelling cellular sub-compartments of genetically-targeted neurons, 2) generating contrast under different EM modalities, and 3) segmenting labelled structures from EM volumes using computer-assisted strategies. We also tested non-destructive X-ray imaging on whole Drosophila brains to evaluate contrast staining. This enabled us to target specific regions for EM volume acquisition. PMID:27958322

  13. Slotted rotatable target assembly and systematic error analysis for a search for long range spin dependent interactions from exotic vector boson exchange using neutron spin rotation

    NASA Astrophysics Data System (ADS)

    Haddock, C.; Crawford, B.; Fox, W.; Francis, I.; Holley, A.; Magers, S.; Sarsour, M.; Snow, W. M.; Vanderwerp, J.

    2018-03-01

    We discuss the design and construction of a novel target array of nonmagnetic test masses used in a neutron polarimetry measurement made in search for new possible exotic spin dependent neutron-atominteractions of Nature at sub-mm length scales. This target was designed to accept and efficiently transmit a transversely polarized slow neutron beam through a series of long open parallel slots bounded by flat rectangular plates. These openings possessed equal atom density gradients normal to the slots from the flat test masses with dimensions optimized to achieve maximum sensitivity to an exotic spin-dependent interaction from vector boson exchanges with ranges in the mm - μm regime. The parallel slots were oriented differently in four quadrants that can be rotated about the neutron beam axis in discrete 90°increments using a Geneva drive. The spin rotation signals from the 4 quadrants were measured using a segmented neutron ion chamber to suppress possible systematic errors from stray magnetic fields in the target region. We discuss the per-neutron sensitivity of the target to the exotic interaction, the design constraints, the potential sources of systematic errors which could be present in this design, and our estimate of the achievable sensitivity using this method.

  14. Functional properties of Mozzarella cheese for its end use application.

    PubMed

    Ah, Jana; Tagalpallewar, Govind P

    2017-11-01

    Cheese is an extremely versatile food product that has a wide range of flavor, textures and end uses. The vast majority of cheese is eaten not by itself, but as part of another food. As an ingredient in foods, cheese is required to exhibit functional characteristics in the raw as well as cooked forms. Melting, stretching, free-oil formation, elasticity and browning are the functional properties considered to be significant for Mozzarella cheese. When a cheese is destined for its end use, some of its unique characteristics play a significant role in the products acceptability. For instance pH of cheese determines the cheese structure which in turn decides the cheese shredability and meltability properties. The residual galactose content in cheese mass determines the propensity of cheese to brown during baking. Development of 'tailor-made cheese' involves focusing on manipulation of such unique traits of cheese in order to obtain the desired characteristics for its end use application suiting the varied consumer's whims and wishes. This comprehensive review paper will provide an insight to the cheese maker regarding the factors determining the functional properties of cheese and also for the pizza manufacturers to decide which age of cheese to be used which will perform well in baking applications.

  15. Automated Target Planning for FUSE Using the SOVA Algorithm

    NASA Technical Reports Server (NTRS)

    Heatwole, Scott; Lanzi, R. James; Civeit, Thomas; Calvani, Humberto; Kruk, Jeffrey W.; Suchkov, Anatoly

    2007-01-01

    IRUs and four reaction wheels. Over time through various failures, the satellite has been left with one reaction wheel on the vehicle skew axis and two gyros. To remain operational, a control scheme has been implemented using the magnetic torque rods and the remaining momentum wheel.[2] As a consequence, there are attitude regions where there is insufficient torque authority to overcome environmental disturbances (e.g. gravity gradient torques). The situation is further complicated by the fact that these attitude regions shift inertially with time as the spacecraft moves through earth s magnetic field during the course of its orbit. Under these conditions, the burden of planning targets and target-to-target slew maneuvers has increased significantly since the beginning of the mission.[3] Individual targets must be selected so that the magnetic field remains roughly aligned with the skew wheel axis to provide enough control authority to the other two orthogonal axes. If the field moves too far away from the skew axis, the lack of control authority allows environmental torques to pull the satellite away from the target and can potentially cause it to tumble. Slew maneuver planning must factor the stability of targets at the beginning and end, and the torque authority at all points along the slew. Due to the time varying magnetic field geometry relative to any two inertial targets, small modifications in slew maneuver timing can make large differences in the achievability of a maneuver.

  16. Hardware test program for evaluation of baseline range/range rate sensor concept

    NASA Technical Reports Server (NTRS)

    Pernic, E.

    1985-01-01

    The test program Phase II effort provides additional design information in terms of range and range rate (R/R) sensor performance when observing and tracking a typical spacecraft target. The target used in the test program was a one-third scale model of the Hubble Space Telescope (HST) available at the MSFC test site where the tests were performed. A modified Bendix millimeter wave radar served as the R/R sensor test bed for evaluation of range and range rate tracking performance, and generation of radar signature characteristics of the spacecraft target. A summary of program test results and conclusions are presented along with detailed description of the Bendix test bed radar with accompaning instrumentation. The MSFC test site and facilities are described. The test procedures used to establish background levels, and the calibration procedures used in the range accuracy tests and RCS (radar cross section) signature measurements, are presented and a condensed version of the daily log kept during the 5 September through 17 September test period is also presented. The test program results are given starting with the RCS signature measurements, then continuing with range measurement accuracy test results and finally the range and range rate tracking accuracy test results.

  17. Particle induced nuclear reaction calculations of Boron target nuclei

    NASA Astrophysics Data System (ADS)

    Tel, Eyyup; Sahan, Muhittin; Sarpün, Ismail Hakki; Kavun, Yusuf; Gök, Ali Armagan; Poyraz, Meltem

    2017-09-01

    Boron is usable element in many areas such as health, industry and energy. Especially, Boron neutron capture therapy (BNCT) is one of the medical applications. Boron target is irradiated with low energy thermal neutrons and at the end of reactions alpha particles occur. After this process recoiling lithium-7 nuclei is composed. In this study, charge particle induced nuclear reactions calculations of Boron target nuclei were investigated in the incident proton and alpha energy range of 5-50 MeV. The excitation functions for 10B target nuclei reactions have been calculated by using PCROSS Programming code. The semi-empirical calculations for (p,α) reactions have been done by using cross section formula with new coefficient obtained by Tel et al. The calculated results were compared with the experimental data from the literature.

  18. From Theory to Practice: Measuring end-of-life communication quality using multiple goals theory.

    PubMed

    Van Scoy, L J; Scott, A M; Reading, J M; Chuang, C H; Chinchilli, V M; Levi, B H; Green, M J

    2017-05-01

    To describe how multiple goals theory can be used as a reliable and valid measure (i.e., coding scheme) of the quality of conversations about end-of-life issues. We analyzed conversations from 17 conversations in which 68 participants (mean age=51years) played a game that prompted discussion in response to open-ended questions about end-of-life issues. Conversations (mean duration=91min) were audio-recorded and transcribed. Communication quality was assessed by three coders who assigned numeric scores rating how well individuals accomplished task, relational, and identity goals in the conversation. The coding measure, which results in a quantifiable outcome, yielded strong reliability (intra-class correlation range=0.73-0.89 and Cronbach's alpha range=0.69-0.89 for each of the coded domains) and validity (using multilevel nonlinear modeling, we detected significant variability in scores between games for each of the coded domains, all p-values <0.02). Our coding scheme provides a theory-based measure of end-of-life conversation quality that is superior to other methods of measuring communication quality. Our description of the coding method enables researches to adapt and apply this measure to communication interventions in other clinical contexts. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Enhanced cellular transport and drug targeting using dendritic nanostructures

    NASA Astrophysics Data System (ADS)

    Kannan, R. M.; Kolhe, Parag; Kannan, Sujatha; Lieh-Lai, Mary

    2003-03-01

    Dendrimers and hyperbranched polymers possess highly branched architectures, with a large number of controllable, tailorable, peripheral' functionalities. Since the surface chemistry of these materials can be modified with relative ease, these materials have tremendous potential in targeted drug delivery. The large density of end groups can also be tailored to create enhanced affinity to targeted cells, and can also encapsulate drugs and deliver them in a controlled manner. We are developing tailor-modified dendritic systems for drug delivery. Synthesis, drug/ligand conjugation, in vitro cellular and in vivo drug delivery, and the targeting efficiency to the cell are being studied systematically using a wide variety of experimental tools. Results on PAMAM dendrimers and polyol hyperbranched polymers suggest that: (1) These materials complex/encapsulate a large number of drug molecules and release them at tailorable rates; (2) The drug-dendrimer complex is transported very rapidly through a A549 lung epithelial cancel cell line, compared to free drug, perhaps by endocytosis. The ability of the drug-dendrimer-ligand complexes to target specific asthma and cancer cells is currently being explored using in vitro and in vivo animal models.

  20. A multicentre 'end to end' dosimetry audit of motion management (4DCT-defined motion envelope) in radiotherapy.

    PubMed

    Palmer, Antony L; Nash, David; Kearton, John R; Jafari, Shakardokht M; Muscat, Sarah

    2017-12-01

    External dosimetry audit is valuable for the assurance of radiotherapy quality. However, motion management has not been rigorously audited, despite its complexity and importance for accuracy. We describe the first end-to-end dosimetry audit for non-SABR (stereotactic ablative body radiotherapy) lung treatments, measuring dose accumulation in a moving target, and assessing adequacy of target dose coverage. A respiratory motion lung-phantom with custom-designed insert was used. Dose was measured with radiochromic film, employing triple-channel dosimetry and uncertainty reduction. The host's 4DCT scan, outlining and planning techniques were used. Measurements with the phantom static and then moving at treatment delivery separated inherent treatment uncertainties from motion effects. Calculated and measured dose distributions were compared by isodose overlay, gamma analysis, and we introduce the concept of 'dose plane histograms' for clinically relevant interpretation of film dosimetry. 12 radiotherapy centres and 19 plans were audited: conformal, IMRT (intensity modulated radiotherapy) and VMAT (volumetric modulated radiotherapy). Excellent agreement between planned and static-phantom results were seen (mean gamma pass 98.7% at 3% 2 mm). Dose blurring was evident in the moving-phantom measurements (mean gamma pass 88.2% at 3% 2 mm). Planning techniques for motion management were adequate to deliver the intended moving-target dose coverage. A novel, clinically-relevant, end-to-end dosimetry audit of motion management strategies in radiotherapy is reported. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Antisense targeting of 3' end elements involved in DUX4 mRNA processing is an efficient therapeutic strategy for facioscapulohumeral dystrophy: a new gene-silencing approach.

    PubMed

    Marsollier, Anne-Charlotte; Ciszewski, Lukasz; Mariot, Virginie; Popplewell, Linda; Voit, Thomas; Dickson, George; Dumonceaux, Julie

    2016-04-15

    Defects in mRNA 3'end formation have been described to alter transcription termination, transport of the mRNA from the nucleus to the cytoplasm, stability of the mRNA and translation efficiency. Therefore, inhibition of polyadenylation may lead to gene silencing. Here, we choose facioscapulohumeral dystrophy (FSHD) as a model to determine whether or not targeting key 3' end elements involved in mRNA processing using antisense oligonucleotide drugs can be used as a strategy for gene silencing within a potentially therapeutic context. FSHD is a gain-of-function disease characterized by the aberrant expression of the Double homeobox 4 (DUX4) transcription factor leading to altered pathogenic deregulation of multiple genes in muscles. Here, we demonstrate that targeting either the mRNA polyadenylation signal and/or cleavage site is an efficient strategy to down-regulate DUX4 expression and to decrease the abnormally high-pathological expression of genes downstream of DUX4. We conclude that targeting key functional 3' end elements involved in pre-mRNA to mRNA maturation with antisense drugs can lead to efficient gene silencing and is thus a potentially effective therapeutic strategy for at least FSHD. Moreover, polyadenylation is a crucial step in the maturation of almost all eukaryotic mRNAs, and thus all mRNAs are virtually eligible for this antisense-mediated knockdown strategy. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Aquarius Whole Range Calibration: Celestial Sky, Ocean, and Land Targets

    NASA Technical Reports Server (NTRS)

    Dinnat, Emmanuel P.; Le Vine, David M.; Bindlish, Rajat; Piepmeier, Jeffrey R.; Brown, Shannon T.

    2014-01-01

    Aquarius is a spaceborne instrument that uses L-band radiometers to monitor sea surface salinity globally. Other applications of its data over land and the cryosphere are being developed. Combining its measurements with existing and upcoming L-band sensors will allow for long term studies. For that purpose, the radiometers calibration is critical. Aquarius measurements are currently calibrated over the oceans. They have been found too cold at the low end (celestial sky) of the brightness temperature scale, and too warm at the warm end (land and ice). We assess the impact of the antenna pattern model on the biases and propose a correction. We re-calibrate Aquarius measurements using the corrected antenna pattern and measurements over the Sky and oceans. The performances of the new calibration are evaluated using measurements over well instrument land sites.

  3. Does practicing a wide range of joint angle configurations lead to higher flexibility in a manual obstacle-avoidance target-pointing task?

    PubMed Central

    Bootsma, Reinoud J.; Schoemaker, Marina M.; Otten, Egbert; Mouton, Leonora J.; Bongers, Raoul M.

    2017-01-01

    Flexibility in motor actions can be defined as variability in the use of degrees of freedom (e.g., joint angles in the arm) over repetitions while keeping performance (e.g., fingertip position) stabilized. We examined whether flexibility can be increased through enlarging the joint angle range during practice in a manual obstacle-avoidance target-pointing task. To establish differences in flexibility we partitioned the variability in joint angles over repetitions in variability within (GEV) and variability outside the solution space (NGEV). More GEV than NGEV reflects flexibility; when the ratio of the GEV and NGEV is higher, flexibility is higher. The pretest and posttest consisted of 30 repetitions of manual pointing to a target while moving over a 10 cm high obstacle. To enlarge the joint angle range during practice participants performed 600 target-pointing movements while moving over obstacles of different heights (5–9 cm, 11–15 cm). The results indicated that practicing movements over obstacles of different heights led participants to use enlarged range of joint angles compared to the range of joint angles used in movements over the 10 cm obstacle in the pretest. However, for each individual obstacle neither joint angle variance nor flexibility were higher during practice. We also did not find more flexibility after practice. In the posttest, joint angle variance was in fact smaller than before practice, primarily in GEV. The potential influences of learning effects and the task used that could underlie the results obtained are discussed. We conclude that with this specific type of practice in this specific task, enlarging the range of joint angles does not lead to more flexibility. PMID:28700695

  4. The strategic framework of tuberculosis control and prevention in the elderly: a scoping review towards End TB targets.

    PubMed

    Li, Jun; Chung, Pui-Hong; Leung, Cyrus L K; Nishikiori, Nobuyuki; Chan, Emily Y Y; Yeoh, Eng-Kiong

    2017-06-01

    With the rapid pace of population ageing, tuberculosis (TB) in the elderly increasingly becomes a public health challenge. Despite the increasing burden and high risks for TB in the elderly, targeted strategy has not been well understood and evaluated. We undertook a scoping review to identify current TB strategies, research and policy gaps in the elderly and summarized the results within a strategic framework towards End TB targets. Databases of Embase, MEDLINE, Global health and EBM reviews were searched for original studies, review articles, and policy papers published in English between January 1990 and December 2015. Articles examining TB strategy, program, guideline or intervention in the elderly from public health perspective were included.Nineteen articles met the inclusion criteria. Most of them were qualitative studies, issued in high- and middle-income countries and after 2000. To break the chain of TB transmission and reactivation in the elderly, infection control, interventions of avoiding delay in diagnosis and containment are essential for preventing transmission, especially in elderly institutions and aged immigrants; screening of latent TB infection and preventive therapy had effective impacts on reducing the risk of reactivation and should be used less reluctantly in older people; optimizing early case-finding with a high index of suspicion, systematic screening for prioritized high-risk groups, initial empirical and adequate follow-up treatment with close monitoring and evaluation, as well as enhanced programmatic management are fundamental pillars for active TB elimination. Evaluation of TB epidemiology, risk factors, impacts and cost-effectiveness of interventions, adopting accurate and rapid diagnostic tools, shorter and less toxic preventive therapy, are critical issues for developing strategy in the elderly towards End TB targets.TB control strategies in the elderly were comprehensively mapped in a causal link pathway. The framework and

  5. Faculty Opinions on the Use of Master's Degree End of Program Assessments

    ERIC Educational Resources Information Center

    Burke, Susan K.; Snead, John T.

    2014-01-01

    Library and Information Studies (LIS) faculty members responded to a survey of their opinions on the use, advantages, and disadvantages of a variety of end of program assessments (EPAs) in LIS master's programs. Portfolio was the most widely preferred top choice for EPAs, but opinions ranged from preference for no EPA to preference for a…

  6. 33 CFR 334.200 - Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...

  7. 33 CFR 334.200 - Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...

  8. 33 CFR 334.200 - Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...

  9. Glioma targeting and blood-brain barrier penetration by dual-targeting doxorubincin liposomes.

    PubMed

    Gao, Jian-Qing; Lv, Qing; Li, Li-Ming; Tang, Xin-Jiang; Li, Fan-Zhu; Hu, Yu-Lan; Han, Min

    2013-07-01

    Effective chemotherapy for glioblastoma requires a carrier that can penetrate the blood-brain barrier (BBB) and subsequently target the glioma cells. Dual-targeting doxorubincin (Dox) liposomes were produced by conjugating liposomes with both folate (F) and transferrin (Tf), which were proven effective in penetrating the BBB and targeting tumors, respectively. The liposome was characterized by particle size, Dox entrapment efficiency, and in vitro release profile. Drug accumulation in cells, P-glycoprotein (P-gp) expression, and drug transport across the BBB in the dual-targeting liposome group were examined by using bEnd3 BBB models. In vivo studies demonstrated that the dual-targeting Dox liposomes could transport across the BBB and mainly distribute in the brain glioma. The anti-tumor effect of the dual-targeting liposome was also demonstrated by the increased survival time, decreased tumor volume, and results of both hematoxylin-eosin staining and terminal deoxynucleotidyl transferase dUTP nick end labeling analysis. The dual-targeting Dox liposome could improve the therapeutic efficacy of brain glioma and were less toxic than the Dox solution, showing a dual-targeting effect. These results indicate that this dual-targeting liposome can be used as a potential carrier for glioma chemotherapy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Use of target-date funds in 401(k) plans, 2007.

    PubMed

    Copeland, Craig

    2009-03-01

    a 401(k) plan had automatic enrollment, this analysis was able to proxy for those who could be identified as automatically enrolled. The data show that workers who were considered to be automatically enrolled in their employer's 401(k) plan are significantly more likely to invest all their assets in a target-date fund than those who voluntarily joined, and were also less likely to have extreme all-or-nothing asset allocations to equities. EQUITY ALLOCATIONS AND FUND FAMILIES: One of the major questions surrounding target-date funds is the equity allocations that these funds use over time (the so-called "glide path") as a participant's retirement target date approaches. The glide paths of different target-date funds have significantly different shapes and starting/ending equity allocations. As of 2007, the equity allocation ranges from about 80-90 percent for 2040 funds (for workers about 30 years away from retirement), and from 26-66 percent for 2010 funds (for workers one year away from retirement)--a 40 percentage-point difference. Moreover, the fund families change their relative rank in equity allocation within the different fund years. This analysis finds that the relative rank of the equity allocation within a target-date fund does not appear to affect the percentage of participants investing all their account into that fund. Nevertheless, investors in specific fund families are more likely to invest all their assets in a single target-date fund from that family.

  11. Forecasting long-range atmospheric transport episodes of polychlorinated biphenyls using FLEXPART

    NASA Astrophysics Data System (ADS)

    Halse, Anne Karine; Eckhardt, Sabine; Schlabach, Martin; Stohl, Andreas; Breivik, Knut

    2013-06-01

    The analysis of concentrations of persistent organic pollutants (POPs) in ambient air is costly and can only be done for a limited number of samples. It is thus beneficial to maximize the information content of the samples analyzed via a targeted observation strategy. Using polychlorinated biphenyls (PCBs) as an example, a forecasting system to predict and evaluate long-range atmospheric transport (LRAT) episodes of POPs at a remote site in southern Norway has been developed. The system uses the Lagrangian particle transport model FLEXPART, and can be used for triggering extra ("targeted") sampling when LRAT episodes are predicted to occur. The system was evaluated by comparing targeted samples collected over 12-25 h during individual LRAT episodes with monitoring samples regularly collected over one day per week throughout a year. Measured concentrations in all targeted samples were above the 75th percentile of the concentrations obtained from the regular monitoring program and included the highest measured values of all samples. This clearly demonstrates the success of the targeted sampling strategy.

  12. End-User Applications of Real-Time Earthquake Information in Europe

    NASA Astrophysics Data System (ADS)

    Cua, G. B.; Gasparini, P.; Giardini, D.; Zschau, J.; Filangieri, A. R.; Reakt Wp7 Team

    2011-12-01

    The primary objective of European FP7 project REAKT (Strategies and Tools for Real-Time Earthquake Risk Reduction) is to improve the efficiency of real-time earthquake risk mitigation methods and their capability of protecting structures, infrastructures, and populations. REAKT aims to address the issues of real-time earthquake hazard and response from end-to-end, with efforts directed along the full spectrum of methodology development in earthquake forecasting, earthquake early warning, and real-time vulnerability systems, through optimal decision-making, and engagement and cooperation of scientists and end users for the establishment of best practices for use of real-time information. Twelve strategic test cases/end users throughout Europe have been selected. This diverse group of applications/end users includes civil protection authorities, railway systems, hospitals, schools, industrial complexes, nuclear plants, lifeline systems, national seismic networks, and critical structures. The scale of target applications covers a wide range, from two school complexes in Naples, to individual critical structures, such as the Rion Antirion bridge in Patras, and the Fatih Sultan Mehmet bridge in Istanbul, to large complexes, such as the SINES industrial complex in Portugal and the Thessaloniki port area, to distributed lifeline and transportation networks and nuclear plants. Some end-users are interested in in-depth feasibility studies for use of real-time information and development of rapid response plans, while others intend to install real-time instrumentation and develop customized automated control systems. From the onset, REAKT scientists and end-users will work together on concept development and initial implementation efforts using the data products and decision-making methodologies developed with the goal of improving end-user risk mitigation. The aim of this scientific/end-user partnership is to ensure that scientific efforts are applicable to operational

  13. SU-E-T-268: Proton Radiosurgery End-To-End Testing Using Lucy 3D QA Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, D; Gordon, I; Ghebremedhin, A

    2014-06-01

    Purpose: To check the overall accuracy of proton radiosurgery treatment delivery using ready-made circular collimator inserts and fixed thickness compensating boluses. Methods: Lucy 3D QA phantom (Standard Imaging Inc. WI, USA) inserted with GaFchromicTM film was irradiated with laterally scattered and longitudinally spread-out 126.8 MeV proton beams. The tests followed every step in the proton radiosurgery treatment delivery process: CT scan (GE Lightspeed VCT), target contouring, treatment planning (Odyssey 5.0, Optivus, CA), portal calibration, target localization using robotic couch with image guidance and dose delivery at planned gantry angles. A 2 cm diameter collimator insert in a 4 cm diametermore » radiosurgery cone and a 1.2 cm thick compensating flat bolus were used for all beams. Film dosimetry (RIT114 v5.0, Radiological Imaging Technology, CO, USA) was used to evaluate the accuracy of target localization and relative dose distributions compared to those calculated by the treatment planning system. Results: The localization accuracy was estimated by analyzing the GaFchromic films irradiated at gantry 0, 90 and 270 degrees. We observed 0.5 mm shift in lateral direction (patient left), ±0.9 mm shift in AP direction and ±1.0 mm shift in vertical direction (gantry dependent). The isodose overlays showed good agreement (<2mm, 50% isodose lines) between measured and calculated doses. Conclusion: Localization accuracy depends on gantry sag, CT resolution and distortion, DRRs from treatment planning computer, localization accuracy of image guidance system, fabrication of ready-made aperture and cone housing. The total deviation from the isocenter was 1.4 mm. Dose distribution uncertainty comes from distal end error due to bolus and CT density, in addition to localization error. The planned dose distribution was well matched (>90%) to the measured values 2%/2mm criteria. Our test showed the robustness of our proton radiosurgery treatment delivery system

  14. Direct detection of RNA in vitro and in situ by target-primed RCA: The impact of E. coli RNase III on the detection efficiency of RNA sequences distanced far from the 3'-end.

    PubMed

    Merkiene, Egle; Gaidamaviciute, Edita; Riauba, Laurynas; Janulaitis, Arvydas; Lagunavicius, Arunas

    2010-08-01

    We improved the target RNA-primed RCA technique for direct detection and analysis of RNA in vitro and in situ. Previously we showed that the 3' --> 5' single-stranded RNA exonucleolytic activity of Phi29 DNA polymerase converts the target RNA into a primer and uses it for RCA initiation. However, in some cases, the single-stranded RNA exoribonucleolytic activity of the polymerase is hindered by strong double-stranded structures at the 3'-end of target RNAs. We demonstrate that in such hampered cases, the double-stranded RNA-specific Escherichia coli RNase III efficiently assists Phi29 DNA polymerase in converting the target RNA into a primer. These observations extend the target RNA-primed RCA possibilities to test RNA sequences distanced far from the 3'-end and customize this technique for the inner RNA sequence analysis.

  15. Target identification using Zernike moments and neural networks

    NASA Astrophysics Data System (ADS)

    Azimi-Sadjadi, Mahmood R.; Jamshidi, Arta A.; Nevis, Andrew J.

    2001-10-01

    The development of an underwater target identification algorithm capable of identifying various types of underwater targets, such as mines, under different environmental conditions pose many technical problems. Some of the contributing factors are: targets have diverse sizes, shapes and reflectivity properties. Target emplacement environment is variable; targets may be proud or partially buried. Environmental properties vary significantly from one location to another. Bottom features such as sand, rocks, corals, and vegetation can conceal a target whether it is partially buried or proud. Competing clutter with responses that closely resemble those of the targets may lead to false positives. All the problems mentioned above contribute to overly difficult and challenging conditions that could lead to unreliable algorithm performance with existing methods. In this paper, we developed and tested a shape-dependent feature extraction scheme that provides features invariant to rotation, size scaling and translation; properties that are extremely useful for any target classification problem. The developed schemes were tested on an electro-optical imagery data set collected under different environmental conditions with variable background, range and target types. The electro-optic data set was collected using a Laser Line Scan (LLS) sensor by the Coastal Systems Station (CSS), located in Panama City, Florida. The performance of the developed scheme and its robustness to distortion, rotation, scaling and translation was also studied.

  16. Identifying sensitive ranges in global warming precipitation change dependence on convective parameters

    DOE PAGES

    Bernstein, Diana N.; Neelin, J. David

    2016-04-28

    A branch-run perturbed-physics ensemble in the Community Earth System Model estimates impacts of parameters in the deep convection scheme on current hydroclimate and on end-of-century precipitation change projections under global warming. Regional precipitation change patterns prove highly sensitive to these parameters, especially in the tropics with local changes exceeding 3mm/d, comparable to the magnitude of the predicted change and to differences in global warming predictions among the Coupled Model Intercomparison Project phase 5 models. This sensitivity is distributed nonlinearly across the feasible parameter range, notably in the low-entrainment range of the parameter for turbulent entrainment in the deep convection scheme.more » This suggests that a useful target for parameter sensitivity studies is to identify such disproportionately sensitive dangerous ranges. Here, the low-entrainment range is used to illustrate the reduction in global warming regional precipitation sensitivity that could occur if this dangerous range can be excluded based on evidence from current climate.« less

  17. Identifying sensitive ranges in global warming precipitation change dependence on convective parameters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernstein, Diana N.; Neelin, J. David

    A branch-run perturbed-physics ensemble in the Community Earth System Model estimates impacts of parameters in the deep convection scheme on current hydroclimate and on end-of-century precipitation change projections under global warming. Regional precipitation change patterns prove highly sensitive to these parameters, especially in the tropics with local changes exceeding 3mm/d, comparable to the magnitude of the predicted change and to differences in global warming predictions among the Coupled Model Intercomparison Project phase 5 models. This sensitivity is distributed nonlinearly across the feasible parameter range, notably in the low-entrainment range of the parameter for turbulent entrainment in the deep convection scheme.more » This suggests that a useful target for parameter sensitivity studies is to identify such disproportionately sensitive dangerous ranges. Here, the low-entrainment range is used to illustrate the reduction in global warming regional precipitation sensitivity that could occur if this dangerous range can be excluded based on evidence from current climate.« less

  18. Range shortening, radiation transport, and Rayleigh-Taylor instability phenomena in ion-beam-driven inertial-fusion-reactor-size targets: Implosion, ignition, and burn phases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, K.A.; Tahir, N.A.

    In this paper we present an analysis of the theory of the energy deposition of ions in cold materials and hot dense plasmas together with numerical calculations for heavy and light ions of interest to ion-beam fusion. We have used the g-smcapso-smcapsr-smcapsg-smcapso-smcapsn-smcaps computer code of Long, Moritz, and Tahir (which is an extension of the code originally written for protons by Nardi, Peleg, and Zinamon) to carry out these calculations. The energy-deposition data calculated in this manner has been used in the design of heavy-ion-beam-driven fusion targets suitable for a reactor, by its inclusion in the m-smcapse-smcapsd-smcapsu-smcapss-smcapsa-smcaps code of Christiansen,more » Ashby, and Roberts as extended by Tahir and Long. A number of other improvements have been made in this code and these are also discussed. Various aspects of the theoretical analysis of such targets are discussed including the calculation of the hydrodynamic stability, the hydrodynamic efficiency, and the gain. Various different target designs have been used, some of them new. In general these targets are driven by Bi/sup +/ ions of energy 8--12 GeV, with an input energy of 4--6.5 MJ, with output energies in the range 600--900 MJ, and with gains in the range 120--180. The peak powers are in the range of 500--750 TW. We present detailed calculations of the ablation, compression, ignition, and burn phases. By the application of a new stability analysis which includes ablation and density-gradient effects we show that these targets appear to implode in a stable manner. Thus the targets designed offer working examples suited for use in a future inertial-confinement fusion reactor.« less

  19. Laboratory simulation of tunable diode laser remote measurement of atmospheric gases using topographic targets

    NASA Technical Reports Server (NTRS)

    Webster, C. R.; Grant, W. B.

    1983-01-01

    In order to test the possibility that tunable diode laser (TDL) systems using topographic targets can be applied to the measurement of a variety of gases at concentrations and distances characteristic of industrial gas leaks, a single-ended TDL system was assembled for use with selected topographic targets to detect NO2 at atmospheric pressure and NO2 and NH3 at low pressures. In both cases, the intensity distribution of radiation backscattered from selected targets was found to be heavily weighted to a specular rather than a Lambertian distribution. A sensitivity of 5 ppm-m has been demonstrated for the case of NO2.

  20. Sutureless functional end-to-end anastomosis using a linear stapler with polyglycolic acid felt for intestinal anastomoses.

    PubMed

    Naito, Masanori; Miura, Hirohisa; Nakamura, Takatoshi; Sato, Takeo; Yamanashi, Takahiro; Tsutsui, Atsuko; Watanabe, Masahiko

    2017-05-01

    Gastrointestinal anastomosis remains associated with a considerable burden of morbidity and, in some cases, mortality. Functional end-to-end anastomosis, whilst extremely efficient, is vulnerable to increased intestinal pressure in the immediate postoperative period, which may predispose to development of anastomotic leakage or bleeding. Therefore, there is a requirement for new techniques that facilitate safe and efficacious anastomotic procedures. This study examined the clinical application of functional end-to-end anastomosis with a stapler that automatically applies a bioabsorbable polyglycolic acid sheet (Endo GIA™ Reinforced Reload with Tri-Staple™ Technology). A porcine model was used to examine functional end-to-end anastomosis with and without application of a bioabsorbable polyglycolic acid sheet. As the crotch of the anastomosis is considered the weakest point, a probe was used to test the integrity of these anastomoses. Furthermore, we performed functional end-to-end anastomosis using the Endo GIA™ Reinforced stapler in a clinical series of 20 patients undergoing gastrointestinal tract resection. In all cases, functional end-to-end anastomosis was performed without suture reinforcement. Small intestine anastomoses in the animal study exhibited no weakness at the crotch of the anastomosis, as tested with a probe, suggesting an increased resiliency to conventional complications of functional end-to-end anastomosis. In the clinical population, no postoperative complications were noted. No adhesive intestinal obstruction was noted. Sutureless functional end-to-end anastomosis using the Endo GIA™ Reinforced appears to be safe, efficacious, and straightforward. Reinforcement of the crotch site with a bioabsorbable polyglycolic acid sheet appears to mitigate conventional problems with crotch-site vulnerability.

  1. Evaluation of NASA's end-to-end data systems using DSDS+

    NASA Technical Reports Server (NTRS)

    Rouff, Christopher; Davenport, William; Message, Philip

    1994-01-01

    The Data Systems Dynamic Simulator (DSDS+) is a software tool being developed by the authors to evaluate candidate architectures for NASA's end-to-end data systems. Via modeling and simulation, we are able to quickly predict the performance characteristics of each architecture, to evaluate 'what-if' scenarios, and to perform sensitivity analyses. As such, we are using modeling and simulation to help NASA select the optimal system configuration, and to quantify the performance characteristics of this system prior to its delivery. This paper is divided into the following six sections: (1) The role of modeling and simulation in the systems engineering process. In this section, we briefly describe the different types of results obtained by modeling each phase of the systems engineering life cycle, from concept definition through operations and maintenance; (2) Recent applications of DSDS+. In this section, we describe ongoing applications of DSDS+ in support of the Earth Observing System (EOS), and we present some of the simulation results generated of candidate system designs. So far, we have modeled individual EOS subsystems (e.g. the Solid State Recorders used onboard the spacecraft), and we have also developed an integrated model of the EOS end-to-end data processing and data communications systems (from the payloads onboard to the principle investigator facilities on the ground); (3) Overview of DSDS+. In this section we define what a discrete-event model is, and how it works. The discussion is presented relative to the DSDS+ simulation tool that we have developed, including it's run-time optimization algorithms that enables DSDS+ to execute substantially faster than comparable discrete-event simulation tools; (4) Summary. In this section, we summarize our findings and 'lessons learned' during the development and application of DSDS+ to model NASA's data systems; (5) Further Information; and (6) Acknowledgements.

  2. Slant path range gated imaging of static and moving targets

    NASA Astrophysics Data System (ADS)

    Steinvall, Ove; Elmqvist, Magnus; Karlsson, Kjell; Gustafsson, Ove; Chevalier, Tomas

    2012-06-01

    This paper will report experiments and analysis of slant path imaging using 1.5 μm and 0.8 μm gated imaging. The investigation is a follow up on the measurement reported last year at the laser radar conference at SPIE Orlando. The sensor, a SWIR camera was collecting both passive and active images along a 2 km long path over an airfield. The sensor was elevated by a lift in steps from 1.6-13.5 meters. Targets were resolution charts and also human targets. The human target was holding various items and also performing certain tasks some of high of relevance in defence and security. One of the main purposes with this investigation was to compare the recognition of these human targets and their activities with the resolution information obtained from conventional resolution charts. The data collection of human targets was also made from out roof top laboratory at about 13 m height above ground. The turbulence was measured along the path with anemometers and scintillometers. The camera was collecting both passive and active images in the SWIR region. We also included the Obzerv camera working at 0.8 μm in some tests. The paper will present images for both passive and active modes obtained at different elevations and discuss the results from both technical and system perspectives.

  3. Use of medetomidine and ketamine for immobilization of free-ranging giraffes.

    PubMed

    Bush, M; Grobler, D G; Raath, J P; Phillips, L G; Stamper, M A; Lance, W R

    2001-01-15

    To develop a dosage correlated with shoulder height (SH) in centimeters for effective immobilization of free-ranging giraffes, using a combination of medetomidine (MED) and ketamine (KET) and reversal with atipamezole (ATP). Prospective study. 23 free-ranging giraffes. The drug combination (MED and KET) was administered by use of a projectile dart. Quality of induction, quality of immobilization, and time to recovery following injection of ATP were evaluated. Physiologic variables measured during immobilization included PaO2, PaCO2, oxygen saturation, end-tidal CO2, blood pH, indirect arterial blood pressure, heart and respiratory rates, and rectal temperature. Sixteen giraffes became recumbent with a dosage (mean +/- SD) of 143 +/- 29 microg of MED and 2.7 +/- 0.6 mg of KET/cm of SH. Initially, giraffes were atactic and progressed to lateral recumbency. Three giraffes required casting with ropes for data collection, with dosages of 166 +/- 5 microg of MED and 3.2 +/- 0.6 mg of KET/cm of SH. Four giraffes required administration of etorphine (n = 2) or were cast with ropes (2) for capture but remained dangerous to personnel once recumbent, precluding data collection. In giraffes successfully immobilized, physiologic monitoring revealed hypoxia and increased respiratory rates. Values for PaCO2, end-tidal CO2, and heart rate remained within reference ranges. All giraffes were hypertensive and had a slight increase in rectal temperature. Atipamezole was administered at 340 +/- 20 microg/cm of SH, resulting in rapid and smooth recoveries. Medetomidine and KET was an effective immobilizing combination for free-ranging giraffes; however, at the dosages used, it does not induce adequate analgesia for major manipulative procedures. Quality of induction and immobilization were enhanced if the giraffe was calm. Reversal was rapid and complete following injection of ATP.

  4. High Dynamic Range Cognitive Radio Front Ends: Architecture to Evaluation

    NASA Astrophysics Data System (ADS)

    Ashok, Arun; Subbiah, Iyappan; Varga, Gabor; Schrey, Moritz; Heinen, Stefan

    2016-07-01

    Advent of TV white space digitization has released frequencies from 470 MHz to 790 MHz to be utilized opportunistically. The secondary user can utilize these so called TV spaces in the absence of primary users. The most important challenge for this coexistence is mutual interference. While the strong TV stations can completely saturate the receiver of the cognitive radio (CR), the cognitive radio spurious tones can disturb other primary users and white space devices. The aim of this paper is to address the challenges for enabling cognitive radio applications in WLAN and LTE. In this process, architectural considerations for the design of cognitive radio front ends are discussed. With high-IF converters, faster and flexible implementation of CR enabled WLAN and LTE are shown. The effectiveness of the architecture is shown by evaluating the CR front ends for compliance of standards namely 802.11b/g (WLAN) and 3GPP TS 36.101 (LTE).

  5. Autonomous target recognition using remotely sensed surface vibration measurements

    NASA Astrophysics Data System (ADS)

    Geurts, James; Ruck, Dennis W.; Rogers, Steven K.; Oxley, Mark E.; Barr, Dallas N.

    1993-09-01

    The remotely measured surface vibration signatures of tactical military ground vehicles are investigated for use in target classification and identification friend or foe (IFF) systems. The use of remote surface vibration sensing by a laser radar reduces the effects of partial occlusion, concealment, and camouflage experienced by automatic target recognition systems using traditional imagery in a tactical battlefield environment. Linear Predictive Coding (LPC) efficiently represents the vibration signatures and nearest neighbor classifiers exploit the LPC feature set using a variety of distortion metrics. Nearest neighbor classifiers achieve an 88 percent classification rate in an eight class problem, representing a classification performance increase of thirty percent from previous efforts. A novel confidence figure of merit is implemented to attain a 100 percent classification rate with less than 60 percent rejection. The high classification rates are achieved on a target set which would pose significant problems to traditional image-based recognition systems. The targets are presented to the sensor in a variety of aspects and engine speeds at a range of 1 kilometer. The classification rates achieved demonstrate the benefits of using remote vibration measurement in a ground IFF system. The signature modeling and classification system can also be used to identify rotary and fixed-wing targets.

  6. Closure Report for Corrective Action Unit 408: Bomblet Target Area Tonopah Test Range (TTR), Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mark Krauss

    2010-09-01

    This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 408: Bomblet Target Area (TTR), Tonopah Test Range, Nevada. This CR complies with the requirements of the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management. Corrective Action Unit 408 is located at the Tonopah Test Range, Nevada, and consists of Corrective Action Site (CAS) TA-55-002-TAB2, Bomblet Target Areas. This CAS includes the following seven target areas: • Mid Target • Flightline Bomblet Location •more » Strategic Air Command (SAC) Target Location 1 • SAC Target Location 2 • South Antelope Lake • Tomahawk Location 1 • Tomahawk Location 2 The purpose of this CR is to provide documentation supporting the completed corrective actions and data confirming that the closure objectives for the CAS within CAU 408 were met. To achieve this, the following actions were performed: • Review the current site conditions, including the concentration and extent of contamination. • Implement any corrective actions necessary to protect human health and the environment. • Properly dispose of corrective action and investigation wastes. • Document Notice of Completion and closure of CAU 408 issued by the Nevada Division of Environmental Protection. From July 2009 through August 2010, closure activities were performed as set forth in the Streamlined Approach for Environmental Restoration Plan for CAU 408: Bomblet Target Area, Tonopah Test Range (TTR), Nevada. The purposes of the activities as defined during the data quality objectives process were as follows: • Identify and remove munitions of explosive concern (MEC) associated with DOE activities. • Investigate potential disposal pit locations. • Remove depleted uranium-contaminated fragments and soil. • Determine whether contaminants of concern

  7. Use of Targeted Therapeutics in Epithelial Ovarian Cancer: A Review of Current Literature and Future Directions.

    PubMed

    Vetter, Monica Hagan; Hays, John L

    2018-03-01

    Epithelial ovarian cancer (EOC) is the leading cause of gynecologic cancer death in the United States. Most patients will ultimately fail platinum-based chemotherapy and have the disease recur. Interest is increasing in the use of targeted therapies in the treatment of EOC. This review focuses on the current use of targeted therapeutics in EOC as well as future directions. A literature search of Medline and PubMed was conducted (January 2000-October 2017) to identify recent reports of targeted drugs in EOC. A wide range of targeted therapeutics is currently being used as both monotherapy and in combination in the treatment of EOC. Clinically, the most commonly used classes of drugs currently are antiangiogenics and poly (ADP-ribose) polymerase inhibitors. However, a number of drugs in varying stages in development target a wide range of biochemical pathways. Activity and response rates of these drugs vary greatly. Questions continue about combination drug therapy and appropriate patient selection. The use of targeted therapeutics in the treatment of EOC, both as monotherapy and in combination, will continue to expand as more mechanisms of tumorigenesis are identified. Multiple clinical trials of a wide range of targeted therapeutics are currently ongoing. Evidence-based selection of drug targets and appropriate patient populations will allow strategic application of targeted therapeutics. Copyright © 2018 Elsevier HS Journals, Inc. All rights reserved.

  8. Z dependence of thick-target β-ray backscattering

    NASA Astrophysics Data System (ADS)

    Sharma, K. K.; Singh, M.

    1980-04-01

    Variation of β-ray backscattering with the atomic number of target material has been studied using thick targets of polythene, aluminum, iron, copper, zinc, tin, silver, tungsten, and lead for five β emitters, viz., 35S, 147Pm, 204Tl, 32P, and 90Sr-90Y. Effects of geometry and β-ray end-point energy have been investigated using a reflection geometry in which the geometry factors were varied by more than 40 and β-ray energy varied over a range 0.167-2.27 MeV. It is found that the mean value of the index of Z dependence of β-ray backscattering is 1.840.05 over these regions of geometry and energy. Deviations for soft β emitters have been confirmed as due to air absorption. The importance of these results in studies of two-component systems is emphasized.

  9. CRISPR/Cas9-mediated gene targeting in Arabidopsis using sequential transformation.

    PubMed

    Miki, Daisuke; Zhang, Wenxin; Zeng, Wenjie; Feng, Zhengyan; Zhu, Jian-Kang

    2018-05-17

    Homologous recombination-based gene targeting is a powerful tool for precise genome modification and has been widely used in organisms ranging from yeast to higher organisms such as Drosophila and mouse. However, gene targeting in higher plants, including the most widely used model plant Arabidopsis thaliana, remains challenging. Here we report a sequential transformation method for gene targeting in Arabidopsis. We find that parental lines expressing the bacterial endonuclease Cas9 from the egg cell- and early embryo-specific DD45 gene promoter can improve the frequency of single-guide RNA-targeted gene knock-ins and sequence replacements via homologous recombination at several endogenous sites in the Arabidopsis genome. These heritable gene targeting can be identified by regular PCR. Our approach enables routine and fine manipulation of the Arabidopsis genome.

  10. Electrostatic Spectrograph with a Wide Range of Simultaneously Recorded Energies Composed of Two Coaxial Electrodes with Closed End Faces and a Discrete Combined External Electrode

    NASA Astrophysics Data System (ADS)

    Fishkova, T. Ya.

    2018-01-01

    An optimal set of geometric and electrical parameters of a high-aperture electrostatic charged-particle spectrograph with a range of simultaneously recorded energies of E/ E min = 1-50 has been found by computer simulation, which is especially important for the energy analysis of charged particles during fast processes in various materials. The spectrograph consists of two coaxial electrodes with end faces closed by flat electrodes. The external electrode with a conical-cylindrical form is cut into parts with potentials that increase linearly, except for the last cylindrical part, which is electrically connected to the rear end electrode. The internal cylindrical electrode and the front end electrode are grounded. In the entire energy range, the system is sharply focused on the internal cylindrical electrode, which provides an energy resolution of no worse than 3 × 10-3.

  11. Probing Xist RNA Structure in Cells Using Targeted Structure-Seq

    PubMed Central

    Rutenberg-Schoenberg, Michael; Simon, Matthew D.

    2015-01-01

    The long non-coding RNA (lncRNA) Xist is a master regulator of X-chromosome inactivation in mammalian cells. Models for how Xist and other lncRNAs function depend on thermodynamically stable secondary and higher-order structures that RNAs can form in the context of a cell. Probing accessible RNA bases can provide data to build models of RNA conformation that provide insight into RNA function, molecular evolution, and modularity. To study the structure of Xist in cells, we built upon recent advances in RNA secondary structure mapping and modeling to develop Targeted Structure-Seq, which combines chemical probing of RNA structure in cells with target-specific massively parallel sequencing. By enriching for signals from the RNA of interest, Targeted Structure-Seq achieves high coverage of the target RNA with relatively few sequencing reads, thus providing a targeted and scalable approach to analyze RNA conformation in cells. We use this approach to probe the full-length Xist lncRNA to develop new models for functional elements within Xist, including the repeat A element in the 5’-end of Xist. This analysis also identified new structural elements in Xist that are evolutionarily conserved, including a new element proximal to the C repeats that is important for Xist function. PMID:26646615

  12. Advanced Glycation End Products: A Molecular Target for Vascular Complications in Diabetes.

    PubMed

    Yamagishi, Sho-Ichi; Nakamura, Nobutaka; Suematsu, Mika; Kaseda, Kuniyoshi; Matsui, Takanori

    2015-10-27

    A nonenzymatic reaction between reducing sugars and amino groups of proteins, lipids and nucleic acids contributes to the aging of macromolecules and subsequently alters their structural integrity and function. This process has been known to progress at an accelerated rate under hyperglycemic and/or oxidative stress conditions. Over a course of days to weeks, early glycation products undergo further reactions such as rearrangements and dehydration to become irreversibly cross-linked, fluorescent and senescent macroprotein derivatives termed advanced glycation end products (AGEs). There is a growing body of evidence indicating that interaction of AGEs with their receptor (RAGE) elicits oxidative stress generation and as a result evokes proliferative, inflammatory, thrombotic and fibrotic reactions in a variety of cells. This evidence supports AGEs' involvement in diabetes- and aging-associated disorders such as diabetic vascular complications, cancer, Alzheimer's disease and osteoporosis. Therefore, inhibition of AGE formation could be a novel molecular target for organ protection in diabetes. This report summarizes the pathophysiological role of AGEs in vascular complications in diabetes and discusses the potential clinical utility of measurement of serum levels of AGEs for evaluating organ damage in diabetes.

  13. DNA Breaks and End Resection Measured Genome-wide by End Sequencing.

    PubMed

    Canela, Andres; Sridharan, Sriram; Sciascia, Nicholas; Tubbs, Anthony; Meltzer, Paul; Sleckman, Barry P; Nussenzweig, André

    2016-09-01

    DNA double-strand breaks (DSBs) arise during physiological transcription, DNA replication, and antigen receptor diversification. Mistargeting or misprocessing of DSBs can result in pathological structural variation and mutation. Here we describe a sensitive method (END-seq) to monitor DNA end resection and DSBs genome-wide at base-pair resolution in vivo. We utilized END-seq to determine the frequency and spectrum of restriction-enzyme-, zinc-finger-nuclease-, and RAG-induced DSBs. Beyond sequence preference, chromatin features dictate the repertoire of these genome-modifying enzymes. END-seq can detect at least one DSB per cell among 10,000 cells not harboring DSBs, and we estimate that up to one out of 60 cells contains off-target RAG cleavage. In addition to site-specific cleavage, we detect DSBs distributed over extended regions during immunoglobulin class-switch recombination. Thus, END-seq provides a snapshot of DNA ends genome-wide, which can be utilized for understanding genome-editing specificities and the influence of chromatin on DSB pathway choice. Published by Elsevier Inc.

  14. No Evidence for a Saccadic Range Effect for Visually Guided and Memory-Guided Saccades in Simple Saccade-Targeting Tasks

    PubMed Central

    Vitu, Françoise; Engbert, Ralf; Kliegl, Reinhold

    2016-01-01

    Saccades to single targets in peripheral vision are typically characterized by an undershoot bias. Putting this bias to a test, Kapoula [1] used a paradigm in which observers were presented with two different sets of target eccentricities that partially overlapped each other. Her data were suggestive of a saccadic range effect (SRE): There was a tendency for saccades to overshoot close targets and undershoot far targets in a block, suggesting that there was a response bias towards the center of eccentricities in a given block. Our Experiment 1 was a close replication of the original study by Kapoula [1]. In addition, we tested whether the SRE is sensitive to top-down requirements associated with the task, and we also varied the target presentation duration. In Experiments 1 and 2, we expected to replicate the SRE for a visual discrimination task. The simple visual saccade-targeting task in Experiment 3, entailing minimal top-down influence, was expected to elicit a weaker SRE. Voluntary saccades to remembered target locations in Experiment 3 were expected to elicit the strongest SRE. Contrary to these predictions, we did not observe a SRE in any of the tasks. Our findings complement the results reported by Gillen et al. [2] who failed to find the effect in a saccade-targeting task with a very brief target presentation. Together, these results suggest that unlike arm movements, saccadic eye movements are not biased towards making saccades of a constant, optimal amplitude for the task. PMID:27658191

  15. Target seedling strategies for intensively managed plantations in the Oregon Coast Range

    Treesearch

    Mark Wall

    2011-01-01

    The target Douglas-fir seedling for outplanting on Roseburg Resources Company timberlands is a least-cost, large [stem] caliper 1- to 2-year old bareroot (>8 mm) or container (>6 mm) seedling with good form, high root growth potential, and the ability to withstand browse without the use of browse deterrents. This target is achieved through the use of large cell...

  16. Screening California Current fishery management scenarios using the Atlantis end-to-end ecosystem model

    NASA Astrophysics Data System (ADS)

    Kaplan, Isaac C.; Horne, Peter J.; Levin, Phillip S.

    2012-09-01

    End-to-end marine ecosystem models link climate and oceanography to the food web and human activities. These models can be used as forecasting tools, to strategically evaluate management options and to support ecosystem-based management. Here we report the results of such forecasts in the California Current, using an Atlantis end-to-end model. We worked collaboratively with fishery managers at NOAA’s regional offices and staff at the National Marine Sanctuaries (NMS) to explore the impact of fishery policies on management objectives at different spatial scales, from single Marine Sanctuaries to the entire Northern California Current. In addition to examining Status Quo management, we explored the consequences of several gear switching and spatial management scenarios. Of the scenarios that involved large scale management changes, no single scenario maximized all performance metrics. Any policy choice would involve trade-offs between stakeholder groups and policy goals. For example, a coast-wide 25% gear shift from trawl to pot or longline appeared to be one possible compromise between an increase in spatial management (which sacrificed revenue) and scenarios such as the one consolidating bottom impacts to deeper areas (which did not perform substantially differently from Status Quo). Judged on a coast-wide scale, most of the scenarios that involved minor or local management changes (e.g. within Monterey Bay NMS only) yielded results similar to Status Quo. When impacts did occur in these cases, they often involved local interactions that were difficult to predict a priori based solely on fishing patterns. However, judged on the local scale, deviation from Status Quo did emerge, particularly for metrics related to stationary species or variables (i.e. habitat and local metrics of landed value or bycatch). We also found that isolated management actions within Monterey Bay NMS would cause local fishers to pay a cost for conservation, in terms of reductions in landed

  17. Evolution of the heteroharmonic strategy for target-range computation in the echolocation of Mormoopidae

    PubMed Central

    Mora, Emanuel C.; Macías, Silvio; Hechavarría, Julio; Vater, Marianne; Kössl, Manfred

    2013-01-01

    Echolocating bats use the time elapsed from biosonar pulse emission to the arrival of echo (defined as echo-delay) to assess target-distance. Target-distance is represented in the brain by delay-tuned neurons that are classified as either “heteroharmonic” or “homoharmormic.” Heteroharmonic neurons respond more strongly to pulse-echo pairs in which the timing of the pulse is given by the fundamental biosonar harmonic while the timing of echoes is provided by one (or several) of the higher order harmonics. On the other hand, homoharmonic neurons are tuned to the echo delay between similar harmonics in the emitted pulse and echo. It is generally accepted that heteroharmonic computations are advantageous over homoharmonic computations; i.e., heteroharmonic neurons receive information from call and echo in different frequency-bands which helps to avoid jamming between pulse and echo signals. Heteroharmonic neurons have been found in two species of the family Mormoopidae (Pteronotus parnellii and Pteronotus quadridens) and in Rhinolophus rouxi. Recently, it was proposed that heteroharmonic target-range computations are a primitive feature of the genus Pteronotus that was preserved in the evolution of the genus. Here, we review recent findings on the evolution of echolocation in Mormoopidae, and try to link those findings to the evolution of the heteroharmonic computation strategy (HtHCS). We stress the hypothesis that the ability to perform heteroharmonic computations evolved separately from the ability of using long constant-frequency echolocation calls, high duty cycle echolocation, and Doppler Shift Compensation. Also, we present the idea that heteroharmonic computations might have been of advantage for categorizing prey size, hunting eared insects, and living in large conspecific colonies. We make five testable predictions that might help future investigations to clarify the evolution of the heteroharmonic echolocation in Mormoopidae and other families. PMID

  18. Relationships between structure, in vivo function and long-range axonal target of cortical pyramidal tract neurons.

    PubMed

    Rojas-Piloni, Gerardo; Guest, Jason M; Egger, Robert; Johnson, Andrew S; Sakmann, Bert; Oberlaender, Marcel

    2017-10-11

    Pyramidal tract neurons (PTs) represent the major output cell type of the neocortex. To investigate principles of how the results of cortical processing are broadcasted to different downstream targets thus requires experimental approaches, which provide access to the in vivo electrophysiology of PTs, whose subcortical target regions are identified. On the example of rat barrel cortex (vS1), we illustrate that retrograde tracer injections into multiple subcortical structures allow identifying the long-range axonal targets of individual in vivo recorded PTs. Here we report that soma depth and dendritic path lengths within each cortical layer of vS1, as well as spiking patterns during both periods of ongoing activity and during sensory stimulation, reflect the respective subcortical target regions of PTs. We show that these cellular properties result in a structure-function parameter space that allows predicting a PT's subcortical target region, without the need to inject multiple retrograde tracers.The major output cell type of the neocortex - pyramidal tract neurons (PTs) - send axonal projections to various subcortical areas. Here the authors combined in vivo recordings, retrograde tracings, and reconstructions of PTs in rat somatosensory cortex to show that PT structure and activity can predict specific subcortical targets.

  19. Red ball ranging optimization based on dual camera ranging method

    NASA Astrophysics Data System (ADS)

    Kuang, Lei; Sun, Weijia; Liu, Jiaming; Tang, Matthew Wai-Chung

    2018-05-01

    In this paper, the process of positioning and moving to target red ball by NAO robot through its camera system is analyzed and improved using the dual camera ranging method. The single camera ranging method, which is adapted by NAO robot, was first studied and experimented. Since the existing error of current NAO Robot is not a single variable, the experiments were divided into two parts to obtain more accurate single camera ranging experiment data: forward ranging and backward ranging. Moreover, two USB cameras were used in our experiments that adapted Hough's circular method to identify a ball, while the HSV color space model was used to identify red color. Our results showed that the dual camera ranging method reduced the variance of error in ball tracking from 0.68 to 0.20.

  20. Hybrid monitoring scheme for end-to-end performance enhancement of multicast-based real-time media

    NASA Astrophysics Data System (ADS)

    Park, Ju-Won; Kim, JongWon

    2004-10-01

    As real-time media applications based on IP multicast networks spread widely, end-to-end QoS (quality of service) provisioning for these applications have become very important. To guarantee the end-to-end QoS of multi-party media applications, it is essential to monitor the time-varying status of both network metrics (i.e., delay, jitter and loss) and system metrics (i.e., CPU and memory utilization). In this paper, targeting the multicast-enabled AG (Access Grid) a next-generation group collaboration tool based on multi-party media services, the applicability of hybrid monitoring scheme that combines active and passive monitoring is investigated. The active monitoring measures network-layer metrics (i.e., network condition) with probe packets while the passive monitoring checks both application-layer metrics (i.e., user traffic condition by analyzing RTCP packets) and system metrics. By comparing these hybrid results, we attempt to pinpoint the causes of performance degradation and explore corresponding reactions to improve the end-to-end performance. The experimental results show that the proposed hybrid monitoring can provide useful information to coordinate the performance improvement of multi-party real-time media applications.

  1. Targeted alpha therapy using short-lived alpha-particles and the promise of nanobodies as targeting vehicle

    PubMed Central

    Dekempeneer, Yana; Keyaerts, Marleen; Krasniqi, Ahmet; Puttemans, Janik; Muyldermans, Serge; Lahoutte, Tony; D’huyvetter, Matthias; Devoogdt, Nick

    2016-01-01

    ABSTRACT Introduction: The combination of a targeted biomolecule that specifically defines the target and a radionuclide that delivers a cytotoxic payload offers a specific way to destroy cancer cells. Targeted radionuclide therapy (TRNT) aims to deliver cytotoxic radiation to cancer cells and causes minimal toxicity to surrounding healthy tissues. Recent advances using α-particle radiation emphasizes their potential to generate radiation in a highly localized and toxic manner because of their high level of ionization and short range in tissue. Areas covered: We review the importance of targeted alpha therapy (TAT) and focus on nanobodies as potential beneficial vehicles. In recent years, nanobodies have been evaluated intensively as unique antigen-specific vehicles for molecular imaging and TRNT. Expert opinion: We expect that the efficient targeting capacity and fast clearance of nanobodies offer a high potential for TAT. More particularly, we argue that the nanobodies’ pharmacokinetic properties match perfectly with the interesting decay properties of the short-lived α-particle emitting radionuclides Astatine-211 and Bismuth-213 and offer an interesting treatment option particularly for micrometastatic cancer and residual disease. PMID:27145158

  2. Real-time multisensor data fusion for target detection, classification, tracking, counting, and range estimates

    NASA Astrophysics Data System (ADS)

    Tsui, Eddy K.; Thomas, Russell L.

    2004-09-01

    As part of the Commanding General of Army Material Command's Research, Development & Engineering Command (RDECOM), the U.S. Army Research Development and Engineering Center (ARDEC), Picatinny funded a joint development effort with McQ Associates, Inc. to develop an Advanced Minefield Sensor (AMS) as a technology evaluation prototype for the Anti-Personnel Landmine Alternatives (APLA) Track III program. This effort laid the fundamental groundwork of smart sensors for detection and classification of targets, identification of combatant or noncombatant, target location and tracking at and between sensors, fusion of information across targets and sensors, and automatic situation awareness to the 1st responder. The efforts have culminated in developing a performance oriented architecture meeting the requirements of size, weight, and power (SWAP). The integrated digital signal processor (DSP) paradigm is capable of computing signals from sensor modalities to extract needed information within either a 360° or fixed field of view with acceptable false alarm rate. This paper discusses the challenges in the developments of such a sensor, focusing on achieving reasonable operating ranges, achieving low power, small size and low cost, and applications for extensions of this technology.

  3. End-to-end performance measurement of Internet based medical applications.

    PubMed

    Dev, P; Harris, D; Gutierrez, D; Shah, A; Senger, S

    2002-01-01

    We present a method to obtain an end-to-end characterization of the performance of an application over a network. This method is not dependent on any specific application or type of network. The method requires characterization of network parameters, such as latency and packet loss, between the expected server or client endpoints, as well as characterization of the application's constraints on these parameters. A subjective metric is presented that integrates these characterizations and that operates over a wide range of applications and networks. We believe that this method may be of wide applicability as research and educational applications increasingly make use of computation and data servers that are distributed over the Internet.

  4. Gene replacements and insertions in rice by intron targeting using CRISPR-Cas9.

    PubMed

    Li, Jun; Meng, Xiangbing; Zong, Yuan; Chen, Kunling; Zhang, Huawei; Liu, Jinxing; Li, Jiayang; Gao, Caixia

    2016-09-12

    Sequence-specific nucleases have been exploited to create targeted gene knockouts in various plants(1), but replacing a fragment and even obtaining gene insertions at specific loci in plant genomes remain a serious challenge. Here, we report efficient intron-mediated site-specific gene replacement and insertion approaches that generate mutations using the non-homologous end joining (NHEJ) pathway using the clustered regularly interspaced short palindromic repeats (CRISPR)-CRISPR-associated protein 9 (Cas9) system. Using a pair of single guide RNAs (sgRNAs) targeting adjacent introns and a donor DNA template including the same pair of sgRNA sites, we achieved gene replacements in the rice endogenous gene 5-enolpyruvylshikimate-3-phosphate synthase (EPSPS) at a frequency of 2.0%. We also obtained targeted gene insertions at a frequency of 2.2% using a sgRNA targeting one intron and a donor DNA template including the same sgRNA site. Rice plants harbouring the OsEPSPS gene with the intended substitutions were glyphosate-resistant. Furthermore, the site-specific gene replacements and insertions were faithfully transmitted to the next generation. These newly developed approaches can be generally used to replace targeted gene fragments and to insert exogenous DNA sequences into specific genomic sites in rice and other plants.

  5. The Kepler End-to-End Data Pipeline: From Photons to Far Away Worlds

    NASA Technical Reports Server (NTRS)

    Cooke, Brian; Thompson, Richard; Standley, Shaun

    2012-01-01

    Launched by NASA on 6 March 2009, the Kepler Mission has been observing more than 100,000 targets in a single patch of sky between the constellations Cygnus and Lyra almost continuously for the last two years looking for planetary systems using the transit method. As of October 2011, the Kepler spacecraft has collected and returned to Earth just over 290 GB of data, identifying 1235 planet candidates with 25 of these candidates confirmed as planets via ground observation. Extracting the telltale signature of a planetary system from stellar photometry where valid signal transients can be small as a 40 ppm is a difficult and exacting task. The end-to end processing of determining planetary candidates from noisy, raw photometric measurements is discussed.

  6. Detection of Accelerating Targets in Clutter Using a De-Chirping Technique

    DTIC Science & Technology

    2014-06-01

    Academy, also in Canberra, working on the the- ory and simulation of spatial optical solitons and light-induced optical switching in nonlinear...signal gain in the receiver. UNCLASSIFIED 1 DSTO–RR–0399 UNCLASSIFIED target along the velocity vector , or equivalently by radar platform. The change of...the tracker uses range rate in its track initiation logic. (2) Lateral acceleration perpendicular to the velocity vector - the target is turning and

  7. Top-attack modeling and automatic target detection using synthetic FLIR scenery

    NASA Astrophysics Data System (ADS)

    Weber, Bruce A.; Penn, Joseph A.

    2004-09-01

    A series of experiments have been performed to verify the utility of algorithmic tools for the modeling and analysis of cold-target signatures in synthetic, top-attack, FLIR video sequences. The tools include: MuSES/CREATION for the creation of synthetic imagery with targets, an ARL target detection algorithm to detect imbedded synthetic targets in scenes, and an ARL scoring algorithm, using Receiver-Operating-Characteristic (ROC) curve analysis, to evaluate detector performance. Cold-target detection variability was examined as a function of target emissivity, surrounding clutter type, and target placement in non-obscuring clutter locations. Detector metrics were also individually scored so as to characterize the effect of signature/clutter variations. Results show that using these tools, a detailed, physically meaningful, target detection analysis is possible and that scenario specific target detectors may be developed by selective choice and/or weighting of detector metrics. However, developing these tools into a reliable predictive capability will require the extension of these results to the modeling and analysis of a large number of data sets configured for a wide range of target and clutter conditions. Finally, these tools should also be useful for the comparison of competitive detection algorithms by providing well defined, and controllable target detection scenarios, as well as for the training and testing of expert human observers.

  8. Laser one-dimensional range profile and the laser two-dimensional range profile of cylinders

    NASA Astrophysics Data System (ADS)

    Gong, Yanjun; Wang, Mingjun; Gong, Lei

    2015-10-01

    Laser one-dimensional range profile, that is scattering power from pulse laser scattering of target, is a radar imaging technology. The laser two-dimensional range profile is two-dimensional scattering imaging of pulse laser of target. Laser one-dimensional range profile and laser two-dimensional range profile are called laser range profile(LRP). The laser range profile can reflect the characteristics of the target shape and surface material. These techniques were motivated by applications of laser radar to target discrimination in ballistic missile defense. The radar equation of pulse laser is given in this paper. This paper demonstrates the analytical model of laser range profile of cylinder based on the radar equation of the pulse laser. Simulations results of laser one-dimensional range profiles of some cylinders are given. Laser range profiles of cylinder, whose surface material with diffuse lambertian reflectance, is given in this paper. Laser range profiles of different pulse width of cylinder are given in this paper. The influences of geometric parameters, pulse width, attitude on the range profiles are analyzed.

  9. High-speed upper-airway imaging using full-range optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Jing, Joseph; Zhang, Jun; Loy, Anthony Chin; Wong, Brian J. F.; Chen, Zhongping

    2012-11-01

    Obstruction in the upper airway can often cause reductions in breathing or gas exchange efficiency and lead to rest disorders such as sleep apnea. Imaging diagnosis of the obstruction region has been accomplished using computed tomography (CT) and magnetic resonance imaging (MRI). However CT requires the use of ionizing radiation, and MRI typically requires sedation of the patient to prevent motion artifacts. Long-range optical coherence tomography (OCT) has the potential to provide high-speed three-dimensional tomographic images with high resolution and without the use of ionizing radiation. In this paper, we present work on the development of a long-range OCT endoscopic probe with 1.2 mm OD and 20 mm working distance used in conjunction with a modified Fourier domain swept source OCT system to acquire structural and anatomical datasets of the human airway. Imaging from the bottom of the larynx to the end of the nasal cavity is completed within 40 s.

  10. Final Environmental Assessment for the Installation of New JDAM and High Fidelity Targets for the Nevada Test and Training Range

    DTIC Science & Technology

    2004-11-01

    Target Centroid 98 RANW / R SC GIS 04071 Data valid as of 11 Mar 04 rogertargets_a#2.apr Figure 2-3. Chemical/Industrial and High Fidelity Urban...existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding...Fidelity Targets, NTTR Nevada Division of Wildlife – Nevada Test and Training Range JDAM Targets Nevada Natural Heritage Program – Data Request received 8

  11. Zapotec Simulations of Momentum Transfer for Impacts into Thin Aluminum Targets

    NASA Astrophysics Data System (ADS)

    Helminiak, Nathaniel; Sable, Peter; Gullerud, Arne; Hollenshead, Jeromy; Hertel, Gene

    2017-06-01

    The momentum transfers between small, 3.2 mm, aluminum spheres into thin aluminum targets was characterized utilizing the numerical solver, Zapotec, which couples the CTH hydrocode and a transient finite elements code, Sierra/SM. The results are compared to experimental work, conducted at the NASA Ames Research Center. Square 15 × 15cm2 aluminum targets ranged in thickness from 5 to 48.2 mm were impacted at a range of velocities from 1 to 9 km/s. From these tests, the components of spray and ejecta momentum, along the axis of impact, normal to the plate surface, were measured. Variations of hole diameter and target mass loss, with respect to initial projectile velocity, were also recorded. The data presented covers a range of phases corresponding to impact behavior ranging from inelastic collision, through spalling behavior, and ending with complete penetration. Sandia is a multiprogram laboratory, operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  12. 15 CFR 744.2 - Restrictions on certain nuclear end-uses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Restrictions on certain nuclear end... POLICY: END-USER AND END-USE BASED § 744.2 Restrictions on certain nuclear end-uses. (a) General...” does not lessen or otherwise change the responsibilities of persons subject to the EAR. (1) Nuclear...

  13. 15 CFR 744.2 - Restrictions on certain nuclear end-uses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Restrictions on certain nuclear end... POLICY: END-USER AND END-USE BASED § 744.2 Restrictions on certain nuclear end-uses. (a) General...” does not lessen or otherwise change the responsibilities of persons subject to the EAR. (1) Nuclear...

  14. 15 CFR 744.2 - Restrictions on certain nuclear end-uses.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 15 Commerce and Foreign Trade 2 2013-01-01 2013-01-01 false Restrictions on certain nuclear end... POLICY: END-USER AND END-USE BASED § 744.2 Restrictions on certain nuclear end-uses. (a) General...” does not lessen or otherwise change the responsibilities of persons subject to the EAR. (1) Nuclear...

  15. 15 CFR 744.2 - Restrictions on certain nuclear end-uses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 15 Commerce and Foreign Trade 2 2012-01-01 2012-01-01 false Restrictions on certain nuclear end... POLICY: END-USER AND END-USE BASED § 744.2 Restrictions on certain nuclear end-uses. (a) General...” does not lessen or otherwise change the responsibilities of persons subject to the EAR. (1) Nuclear...

  16. 15 CFR 744.2 - Restrictions on certain nuclear end-uses.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 15 Commerce and Foreign Trade 2 2014-01-01 2014-01-01 false Restrictions on certain nuclear end... POLICY: END-USER AND END-USE BASED § 744.2 Restrictions on certain nuclear end-uses. (a) General...” does not lessen or otherwise change the responsibilities of persons subject to the EAR. (1) Nuclear...

  17. Design of an open-ended plenoptic camera for three-dimensional imaging of dusty plasmas

    NASA Astrophysics Data System (ADS)

    Sanpei, Akio; Tokunaga, Kazuya; Hayashi, Yasuaki

    2017-08-01

    Herein, the design of a plenoptic imaging system for three-dimensional reconstructions of dusty plasmas using an integral photography technique has been reported. This open-ended system is constructed with a multi-convex lens array and a typical reflex CMOS camera. We validated the design of the reconstruction system using known target particles. Additionally, the system has been applied to observations of fine particles floating in a horizontal, parallel-plate radio-frequency plasma. Furthermore, the system works well in the range of our dusty plasma experiment. We can identify the three-dimensional positions of dust particles from a single-exposure image obtained from one viewing port.

  18. The Mechanism of Gene Targeting in Human Somatic Cells

    PubMed Central

    Kan, Yinan; Ruis, Brian; Lin, Sherry; Hendrickson, Eric A.

    2014-01-01

    Gene targeting in human somatic cells is of importance because it can be used to either delineate the loss-of-function phenotype of a gene or correct a mutated gene back to wild-type. Both of these outcomes require a form of DNA double-strand break (DSB) repair known as homologous recombination (HR). The mechanism of HR leading to gene targeting, however, is not well understood in human cells. Here, we demonstrate that a two-end, ends-out HR intermediate is valid for human gene targeting. Furthermore, the resolution step of this intermediate occurs via the classic DSB repair model of HR while synthesis-dependent strand annealing and Holliday Junction dissolution are, at best, minor pathways. Moreover, and in contrast to other systems, the positions of Holliday Junction resolution are evenly distributed along the homology arms of the targeting vector. Most unexpectedly, we demonstrate that when a meganuclease is used to introduce a chromosomal DSB to augment gene targeting, the mechanism of gene targeting is inverted to an ends-in process. Finally, we demonstrate that the anti-recombination activity of mismatch repair is a significant impediment to gene targeting. These observations significantly advance our understanding of HR and gene targeting in human cells. PMID:24699519

  19. Teaching and Evaluating Using "Open-Ended Problems" in Classroom.

    ERIC Educational Resources Information Center

    Nohda, Nobuhiko

    1995-01-01

    Discusses advantages and considerations in using open-ended problems in mathematics teaching and evaluation. Describes results of using open-ended problems in a sixth-grade class in Japan. (Author/MKR)

  20. Autonomous Rover Traverse and Precise Arm Placement on Remotely Designated Targets

    NASA Technical Reports Server (NTRS)

    Nesnas, Issa A.; Pivtoraiko, Mihail N.; Kelly, Alonzo; Fleder, Michael

    2012-01-01

    This software controls a rover platform to traverse rocky terrain autonomously, plan paths, and avoid obstacles using its stereo hazard and navigation cameras. It does so while continuously tracking a target of interest selected from 10 20 m away. The rover drives and tracks the target until it reaches the vicinity of the target. The rover then positions itself to approach the target, deploys its robotic arm, and places the end effector instrument on the designated target to within 2-3-cm accuracy of the originally selected target. This software features continuous navigation in a fairly rocky field in an outdoor environment and the ability to enable the rover to avoid large rocks and traverse over smaller ones. Using point-and-click mouse commands, a scientist designates targets in the initial imagery acquired from the rover s mast cameras. The navigation software uses stereo imaging, traversability analysis, path planning, trajectory generation, and trajectory execution. It also includes visual target tracking of a designated target selected from 10 m away while continuously navigating the rocky terrain. Improvements in this design include steering while driving, which uses continuous curvature paths. There are also several improvements to the traversability analyzer, including improved data fusion of traversability maps that result from pose estimation uncertainties, dealing with boundary effects to enable tighter maneuvers, and handling a wider range of obstacles. This work advances what has been previously developed and integrated on the Mars Exploration Rovers by using algorithms that are capable of traversing more rock-dense terrains, enabling tight, thread-the-needle maneuvers. These algorithms were integrated on the newly refurbished Athena Mars research rover, and were fielded in the JPL Mars Yard. Forty-three runs were conducted with targets at distances ranging from 5 to 15 m, and a success rate of 93% was achieved for placement of the instrument within

  1. Active imaging system performance model for target acquisition

    NASA Astrophysics Data System (ADS)

    Espinola, Richard L.; Teaney, Brian; Nguyen, Quang; Jacobs, Eddie L.; Halford, Carl E.; Tofsted, David H.

    2007-04-01

    The U.S. Army RDECOM CERDEC Night Vision & Electronic Sensors Directorate has developed a laser-range-gated imaging system performance model for the detection, recognition, and identification of vehicle targets. The model is based on the established US Army RDECOM CERDEC NVESD sensor performance models of the human system response through an imaging system. The Java-based model, called NVLRG, accounts for the effect of active illumination, atmospheric attenuation, and turbulence effects relevant to LRG imagers, such as speckle and scintillation, and for the critical sensor and display components. This model can be used to assess the performance of recently proposed active SWIR systems through various trade studies. This paper will describe the NVLRG model in detail, discuss the validation of recent model components, present initial trade study results, and outline plans to validate and calibrate the end-to-end model with field data through human perception testing.

  2. Optimisation of the manufacturing process of tritide and deuteride targets used for neutron production

    NASA Astrophysics Data System (ADS)

    Monnin, Carole; Bach, Pierre; Tulle, Pierre Alain; van Rompay, Marc; Ballanger, Anne

    2002-03-01

    As a neutron tube manufacturer, SODERN is now in charge of manufacturing tritium targets for accelerators, in cooperation with CEA/DAM/DTMN in Valduc. Specific deuterium and tritium targets are manufactured on request, according to the requirements of the users, starting from titanium targets on copper substrates, and going to more sophisticated devices. The range of possible uses is wide, including thin targets for neutron calibration, thick targets with controlled loading of deuterium and tritium, rotating targets or large size rotating targets for higher lifetimes. The activity of the targets ranges from 3.7×10 10 to 3.7×10 13 Bq (1-1000 Ci), the diameter being up to 30 cm. Sodern and the CEA/Valduc centre have developed different technologies for tritium target manufacture, allowing the selection of the best configuration for each kind of use. In order to optimize the production of high energy neutrons, the performance of tritide and deuteride titanium targets made by different processes has been studied experimentally by bombardment with 120 and 350 kV deuterons provided by electrostatic accelerators. It is then possible to optimize either neutron output or lifetime and stability or thermal behaviour. The importance of the deposit evaporation conditions on the efficiency of neutron emission is clearly demonstrated, as well as the thermomechanical stability of the Ti thin film under deuteron bombardment. The main parameters involved in the target performance are discussed from a thermodynamical approach.

  3. Spectrally tunable, temporally shaped parametric front end to seed high-energy Nd:glass laser systems

    DOE PAGES

    Dorrer, C.; Consentino, A.; Cuffney, R.; ...

    2017-10-18

    Here, we describe a parametric-amplification–based front end for seeding high-energy Nd:glass laser systems. The front end delivers up to 200 mJ by parametric amplification in 2.5-ns flat-in-time pulses tunable over more than 15 nm. Spectral tunability over a range larger than what is typically achieved by laser media at similar energy levels is implemented to investigate cross-beam energy transfer in multibeam target experiments. The front-end operation is simulated to explain the amplified signal’s sensitivity to the input pump and signal. A large variety of amplified waveforms are generated by closed-loop pulse shaping. Various properties and limitations of this front endmore » are discussed.« less

  4. Spectrally tunable, temporally shaped parametric front end to seed high-energy Nd:glass laser systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dorrer, C.; Consentino, A.; Cuffney, R.

    Here, we describe a parametric-amplification–based front end for seeding high-energy Nd:glass laser systems. The front end delivers up to 200 mJ by parametric amplification in 2.5-ns flat-in-time pulses tunable over more than 15 nm. Spectral tunability over a range larger than what is typically achieved by laser media at similar energy levels is implemented to investigate cross-beam energy transfer in multibeam target experiments. The front-end operation is simulated to explain the amplified signal’s sensitivity to the input pump and signal. A large variety of amplified waveforms are generated by closed-loop pulse shaping. Various properties and limitations of this front endmore » are discussed.« less

  5. Wireless network of stand-alone end effect probes for soil in situ permittivity measurements over the 100MHZ-6GHz frequency range

    NASA Astrophysics Data System (ADS)

    Demontoux, François; Bircher, Simone; Ruffié, Gilles; Bonnaudiin, Fabrice; Wigneron, Jean-Pierre; Kerr, Yann

    2017-04-01

    Microwave remote sensing and non-destructive analysis are a powerful way to provide properties estimation of materials. Numerous applications using microwave frequency behavior of materials (remote sensing above land surfaces, non-destructive analysis…) are strongly dependent on the material's permittivity (i.e. dielectric properties). This permittivity depends on numerous parameters such as moisture, texture, temperature, frequency or bulk density. Permittivity measurements are generally carried out in the laboratory. Additionally, dielectric mixing models allow, over a restricted range of conditions, the assessment of a material's permittivity. in-situ measurements are more difficult to obtain. Some in situ measurement probes based on permittivity properties of soil exist (e.g. Time Domain Reflectometers and Transmissometers, capacitance and impedance sensors). They are dedicated to the acquisition of soil moisture data based on permittivity (mainly the real part) estimations over a range of frequencies from around 50 MHz to 1 or 2 GHz. Other Dielectric Assessment Kits exist but they are expensive and they are rather dedicated to laboratory measurements. Furthermore, the user can't address specific issues related to particular materials (e.g. organic soils) or specific measurement conditions (in situ long time records). At the IMS Laboratory we develop probes for in situ soil permittivity measurements (real and imaginary parts) in the 0.5 - 6 GHz frequency range. They are based on the end effect phenomenon of a coaxial waveguide and so are called end effect probes in this paper. The probes can be connected to a portable Vector Network Analyzer (VNA, ANRITSU MS2026A) for the S11 coefficient measurements needed to compute permittivity. It is connected to a PC to record data using an USB connection. This measurement set-up is already used for in situ measurement of soil properties in the framework of the European Space Agency's (ESA) SMOS space mission. However

  6. TargetSpy: a supervised machine learning approach for microRNA target prediction.

    PubMed

    Sturm, Martin; Hackenberg, Michael; Langenberger, David; Frishman, Dmitrij

    2010-05-28

    Virtually all currently available microRNA target site prediction algorithms require the presence of a (conserved) seed match to the 5' end of the microRNA. Recently however, it has been shown that this requirement might be too stringent, leading to a substantial number of missed target sites. We developed TargetSpy, a novel computational approach for predicting target sites regardless of the presence of a seed match. It is based on machine learning and automatic feature selection using a wide spectrum of compositional, structural, and base pairing features covering current biological knowledge. Our model does not rely on evolutionary conservation, which allows the detection of species-specific interactions and makes TargetSpy suitable for analyzing unconserved genomic sequences.In order to allow for an unbiased comparison of TargetSpy to other methods, we classified all algorithms into three groups: I) no seed match requirement, II) seed match requirement, and III) conserved seed match requirement. TargetSpy predictions for classes II and III are generated by appropriate postfiltering. On a human dataset revealing fold-change in protein production for five selected microRNAs our method shows superior performance in all classes. In Drosophila melanogaster not only our class II and III predictions are on par with other algorithms, but notably the class I (no-seed) predictions are just marginally less accurate. We estimate that TargetSpy predicts between 26 and 112 functional target sites without a seed match per microRNA that are missed by all other currently available algorithms. Only a few algorithms can predict target sites without demanding a seed match and TargetSpy demonstrates a substantial improvement in prediction accuracy in that class. Furthermore, when conservation and the presence of a seed match are required, the performance is comparable with state-of-the-art algorithms. TargetSpy was trained on mouse and performs well in human and drosophila

  7. TargetSpy: a supervised machine learning approach for microRNA target prediction

    PubMed Central

    2010-01-01

    Background Virtually all currently available microRNA target site prediction algorithms require the presence of a (conserved) seed match to the 5' end of the microRNA. Recently however, it has been shown that this requirement might be too stringent, leading to a substantial number of missed target sites. Results We developed TargetSpy, a novel computational approach for predicting target sites regardless of the presence of a seed match. It is based on machine learning and automatic feature selection using a wide spectrum of compositional, structural, and base pairing features covering current biological knowledge. Our model does not rely on evolutionary conservation, which allows the detection of species-specific interactions and makes TargetSpy suitable for analyzing unconserved genomic sequences. In order to allow for an unbiased comparison of TargetSpy to other methods, we classified all algorithms into three groups: I) no seed match requirement, II) seed match requirement, and III) conserved seed match requirement. TargetSpy predictions for classes II and III are generated by appropriate postfiltering. On a human dataset revealing fold-change in protein production for five selected microRNAs our method shows superior performance in all classes. In Drosophila melanogaster not only our class II and III predictions are on par with other algorithms, but notably the class I (no-seed) predictions are just marginally less accurate. We estimate that TargetSpy predicts between 26 and 112 functional target sites without a seed match per microRNA that are missed by all other currently available algorithms. Conclusion Only a few algorithms can predict target sites without demanding a seed match and TargetSpy demonstrates a substantial improvement in prediction accuracy in that class. Furthermore, when conservation and the presence of a seed match are required, the performance is comparable with state-of-the-art algorithms. TargetSpy was trained on mouse and performs well

  8. End-to-End Multimodal Emotion Recognition Using Deep Neural Networks

    NASA Astrophysics Data System (ADS)

    Tzirakis, Panagiotis; Trigeorgis, George; Nicolaou, Mihalis A.; Schuller, Bjorn W.; Zafeiriou, Stefanos

    2017-12-01

    Automatic affect recognition is a challenging task due to the various modalities emotions can be expressed with. Applications can be found in many domains including multimedia retrieval and human computer interaction. In recent years, deep neural networks have been used with great success in determining emotional states. Inspired by this success, we propose an emotion recognition system using auditory and visual modalities. To capture the emotional content for various styles of speaking, robust features need to be extracted. To this purpose, we utilize a Convolutional Neural Network (CNN) to extract features from the speech, while for the visual modality a deep residual network (ResNet) of 50 layers. In addition to the importance of feature extraction, a machine learning algorithm needs also to be insensitive to outliers while being able to model the context. To tackle this problem, Long Short-Term Memory (LSTM) networks are utilized. The system is then trained in an end-to-end fashion where - by also taking advantage of the correlations of the each of the streams - we manage to significantly outperform the traditional approaches based on auditory and visual handcrafted features for the prediction of spontaneous and natural emotions on the RECOLA database of the AVEC 2016 research challenge on emotion recognition.

  9. Measurement of thick target neutron yield from the reaction (p+181 Ta) with projectiles in the range of 6-20 MeV

    NASA Astrophysics Data System (ADS)

    Paul, Sabyasachi; Sahoo, G. S.; Tripathy, S. P.; Sharma, S. C.; Joshi, D. S.; Bandyopadhyay, T.

    2018-02-01

    181Ta is a commonly used backing material for many targets in nuclear reaction studies. When the target thickness is less than the range of bombarded projectiles, the interaction via Ta(p,n) reactions in the backing can be a significant source of background. In this study, the neutron spectral yields from the reaction of protons of different energies (between 6 to 20 MeV) with a thick Ta target were determined using CR-39 detectors. The results from this study can be used as a correction factor in such situations. The parameters of registered tracks in CR-39 were analysed using an in-house image analysing program autoTRAK_n and then to derive the associated dose values. The spectral yields obtained experimentally were compared with those obtained from the theoretical calculations. The neutron yield was found to increase with increase in projectile energy mainly due to the opening of reaction channels from (p, n) to (p, 3n).

  10. Setting population targets for mammals using body mass as a predictor of population persistence.

    PubMed

    Hilbers, Jelle P; Santini, Luca; Visconti, Piero; Schipper, Aafke M; Pinto, Cecilia; Rondinini, Carlo; Huijbregts, Mark A J

    2017-04-01

    Conservation planning and biodiversity assessments need quantitative targets to optimize planning options and assess the adequacy of current species protection. However, targets aiming at persistence require population-specific data, which limit their use in favor of fixed and nonspecific targets, likely leading to unequal distribution of conservation efforts among species. We devised a method to derive equitable population targets; that is, quantitative targets of population size that ensure equal probabilities of persistence across a set of species and that can be easily inferred from species-specific traits. In our method, we used models of population dynamics across a range of life-history traits related to species' body mass to estimate minimum viable population targets. We applied our method to a range of body masses of mammals, from 2 g to 3825 kg. The minimum viable population targets decreased asymptotically with increasing body mass and were on the same order of magnitude as minimum viable population estimates from species- and context-specific studies. Our approach provides a compromise between pragmatic, nonspecific population targets and detailed context-specific estimates of population viability for which only limited data are available. It enables a first estimation of species-specific population targets based on a readily available trait and thus allows setting equitable targets for population persistence in large-scale and multispecies conservation assessments and planning. © 2016 The Authors. Conservation Biology published by Wiley Periodicals, Inc. on behalf of Society for Conservation Biology.

  11. Granule size control and targeting in pulsed spray fluid bed granulation.

    PubMed

    Ehlers, Henrik; Liu, Anchang; Räikkönen, Heikki; Hatara, Juha; Antikainen, Osmo; Airaksinen, Sari; Heinämäki, Jyrki; Lou, Honxiang; Yliruusi, Jouko

    2009-07-30

    The primary aim of the study was to investigate the effects of pulsed liquid feed on granule size. The secondary aim was to increase knowledge of this technique in granule size targeting. Pulsed liquid feed refers to the pump changing between on- and off-positions in sequences, called duty cycles. One duty cycle consists of one on- and off-period. The study was performed with a laboratory-scale top-spray fluid bed granulator with duty cycle length and atomization pressure as studied variables. The liquid feed rate, amount and inlet air temperature were constant. The granules were small, indicating that the powder has only undergone ordered mixing, nucleation and early growth. The effect of atomizing pressure on granule size depends on inlet air relative humidity, with premature binder evaporation as a reason. The duty cycle length was of critical importance to the end product attributes, by defining the extent of intermittent drying and rewetting. By varying only the duty cycle length, it was possible to control granule nucleation and growth, with a wider granule size target range in increased relative humidity. The present study confirms that pulsed liquid feed in fluid bed granulation is a useful tool in end product particle size targeting.

  12. Electrosynthesis of magnetoresponsive microrobot for targeted drug delivery using calcium alginate.

    PubMed

    Chengzhi Hu; Riederer, Katharina; Klemmer, Michael; Pane, Salvador; Nelson, Bradley J

    2016-08-01

    Targeted drug delivery systems deliver drugs precisely to a specific targeted site inside the body, and can also release the drugs with controlled kinetics to prolong the efficacy of single dose administration. The advantageous properties of hydrogels make them attractive for use in the area of drug delivery. Calcium alginate is a pH sensitive hydrogel stable in acidic media and soluble in basic media. This enables the hydrogel to absorb and release aqueous solutions at certain ranges of pH values. By absorbing an aqueous solution containing a drug, an active drug release can be triggered at a specified range of pH value. In this paper, we combined calcium alginate with cobalt nickel (CoNi) in a cylindrical hybrid micro robot by electrodeposition. The designed microrobot can be wirelessly actuated with an external magnetic manipulation system and, hence, targeted to a specific location in the human body. At this specific location, characterized by its pH range, the absorbed drug will be released. Here, the fabrication steps of the specified microrobot are characterized, namely the production of a template on a silicon chip and the subsequent template-assisted electrodeposition of CoNi and alginate. Additionally, the dynamics of drug release of calcium alginate is studied.

  13. Targeting the lymphatics using dendritic polymers (dendrimers).

    PubMed

    Kaminskas, Lisa M; Porter, Christopher J H

    2011-09-10

    Dendrimers are unique biomaterials that are constructed by the stepwise addition of layers (generations) of polymer around a central core. They can be constructed with a range of molecular weights and have a polyfunctional surface that facilitates the attachment of drugs and pharmacokinetic modifiers such PEG or targeting moieties. These properties have led to considerable interest in the development of dendrimers for a range of biomedical applications. After subcutaneous administration, larger dendrimers in particular (> 8 nm), preferentially drain from the injection site into the peripheral lymphatic capillaries and therefore have potential as lymphatic imaging agents for magnetic resonance and optical fluorescence lymphangiography and as vectors for drug-targeting to lymphatic sites of disease progression. In general, lymphatic targeting of dendrimers is enhanced by increasing size although ultimately larger constructs may be incompletely absorbed from the injection site. Increasing hydrophilicity and reducing surface charge enhances drainage from subcutaneous injection sites, but the reverse is true of uptake into lymph nodes where charge and hydrophobicity promote retention. Larger hydrophilic dendrimers are also capable of extravasation from the systemic circulation, absorption into the lymphatic system and recirculation into the blood. Lymphatic recirculation may therefore be a characteristic of PEGylated dendrimers with long systemic circulation times. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Improving End-of-Life Care: Palliative Care Embedded in an Oncology Clinic Specializing in Targeted and Immune-Based Therapies.

    PubMed

    Einstein, David J; DeSanto-Madeya, Susan; Gregas, Matthew; Lynch, Jessica; McDermott, David F; Buss, Mary K

    2017-09-01

    Patients with advanced cancer benefit from early involvement of palliative care. The ideal method of palliative care integration remains to be determined, as does its effectiveness for patients treated with targeted and immune-based therapies. We studied the impact of an embedded palliative care team that saw patients in an academic oncology clinic specializing in targeted and immune-based therapies. Patients seen on a specific day accessed the embedded model, on the basis of automatic criteria; patients seen other days could be referred to a separate palliative care clinic (usual care). We abstracted data from the medical records of 114 patients who died during the 3 years after this model's implementation. Compared with usual care (n = 88), patients with access to the embedded model (n = 26) encountered palliative care as outpatients more often ( P = .003) and earlier (mean, 231 v 109 days before death; P < .001). Hospice enrollment rates were similar ( P = .303), but duration was doubled (mean, 57 v 25 days; P = .006), and enrollment > 7 days before death-a core Quality Oncology Practice Initiative metric-was higher in the embedded model (odds ratio, 5.60; P = .034). Place of death ( P = .505) and end-of-life chemotherapy (odds ratio, 0.361; P = .204) did not differ between the two arms. A model of embedded and automatically triggered palliative care among patients treated exclusively with targeted and immune-based therapies was associated with significant improvements in use and timing of palliative care and hospice, compared with usual practice.

  15. An end-to-end framework for real-time automatic sleep stage classification

    PubMed Central

    Ong, Ju Lynn; Gooley, Joshua J; Ancoli-Israel, Sonia; Chee, Michael W L

    2018-01-01

    Abstract Sleep staging is a fundamental but time consuming process in any sleep laboratory. To greatly speed up sleep staging without compromising accuracy, we developed a novel framework for performing real-time automatic sleep stage classification. The client–server architecture adopted here provides an end-to-end solution for anonymizing and efficiently transporting polysomnography data from the client to the server and for receiving sleep stages in an interoperable fashion. The framework intelligently partitions the sleep staging task between the client and server in a way that multiple low-end clients can work with one server, and can be deployed both locally as well as over the cloud. The framework was tested on four datasets comprising ≈1700 polysomnography records (≈12000 hr of recordings) collected from adolescents, young, and old adults, involving healthy persons as well as those with medical conditions. We used two independent validation datasets: one comprising patients from a sleep disorders clinic and the other incorporating patients with Parkinson’s disease. Using this system, an entire night’s sleep was staged with an accuracy on par with expert human scorers but much faster (≈5 s compared with 30–60 min). To illustrate the utility of such real-time sleep staging, we used it to facilitate the automatic delivery of acoustic stimuli at targeted phase of slow-sleep oscillations to enhance slow-wave sleep. PMID:29590492

  16. Target-similarity search using Plasmodium falciparum proteome identifies approved drugs with anti-malarial activity and their possible targets

    PubMed Central

    Akala, Hoseah M.; Macharia, Rosaline W.; Juma, Dennis W.; Cheruiyot, Agnes C.; Andagalu, Ben; Brown, Mathew L.; El-Shemy, Hany A.; Nyanjom, Steven G.

    2017-01-01

    Malaria causes about half a million deaths annually, with Plasmodium falciparum being responsible for 90% of all the cases. Recent reports on artemisinin resistance in Southeast Asia warrant urgent discovery of novel drugs for the treatment of malaria. However, most bioactive compounds fail to progress to treatments due to safety concerns. Drug repositioning offers an alternative strategy where drugs that have already been approved as safe for other diseases could be used to treat malaria. This study screened approved drugs for antimalarial activity using an in silico chemogenomics approach prior to in vitro verification. All the P. falciparum proteins sequences available in NCBI RefSeq were mined and used to perform a similarity search against DrugBank, TTD and STITCH databases to identify similar putative drug targets. Druggability indices of the potential P. falciparum drug targets were obtained from TDR targets database. Functional amino acid residues of the drug targets were determined using ConSurf server which was used to fine tune the similarity search. This study predicted 133 approved drugs that could target 34 P. falciparum proteins. A literature search done at PubMed and Google Scholar showed 105 out of the 133 drugs to have been previously tested against malaria, with most showing activity. For further validation, drug susceptibility assays using SYBR Green I method were done on a representative group of 10 predicted drugs, eight of which did show activity against P. falciparum 3D7 clone. Seven had IC50 values ranging from 1 μM to 50 μM. This study also suggests drug-target association and hence possible mechanisms of action of drugs that did show antiplasmodial activity. The study results validate the use of proteome-wide target similarity approach in identifying approved drugs with activity against P. falciparum and could be adapted for other pathogens. PMID:29088219

  17. A front-end read out chip for the OPERA scintillator tracker

    NASA Astrophysics Data System (ADS)

    Lucotte, A.; Bondil, S.; Borer, K.; Campagne, J. E.; Cazes, A.; Hess, M.; de La Taille, C.; Martin-Chassard, G.; Raux, L.; Repellin, J. P.

    2004-04-01

    Multi-anode photomultipliers H7546 are used to readout signal from the OPERA Scintillator Tracker (CERN/SPSC 2000-028, SPSC/P318, LNGSP 25/2000; CERN/SPSC 2001-025, SPSC/M668, LNGS-EXP30/2001). A 32-channel front-end Read Out Chip prototype accommodating the H7546 has been designed at LAL. This device features a low-noise, variable gain preamplifier to correct for multi-anode non-uniformity, an auto-trigger capability 100% efficient at a 0.3 photo-electron, and a charge measurement extending over a large dynamic range [0-100] photo-electrons. In this article we describe the ASIC architecture that is being implemented for the Target Tracker in OPERA, with a special emphasis put on the designs and the measured performance.

  18. Efficient targeted mutagenesis in the monarch butterfly using zinc-finger nucleases

    PubMed Central

    Merlin, Christine; Beaver, Lauren E.; Taylor, Orley R.; Wolfe, Scot A.; Reppert, Steven M.

    2013-01-01

    The development of reverse-genetic tools in “nonmodel” insect species with distinct biology is critical to establish them as viable model systems. The eastern North American monarch butterfly (Danaus plexippus), whose genome is sequenced, has emerged as a model to study animal clocks, navigational mechanisms, and the genetic basis of long-distance migration. Here, we developed a highly efficient gene-targeting approach in the monarch using zinc-finger nucleases (ZFNs), engineered nucleases that generate mutations at targeted genomic sequences. We focused our ZFN approach on targeting the type 2 vertebrate-like cryptochrome gene of the monarch (designated cry2), which encodes a putative transcriptional repressor of the monarch circadian clockwork. Co-injections of mRNAs encoding ZFNs targeting the second exon of monarch cry2 into “one nucleus” stage embryos led to high-frequency nonhomologous end-joining-mediated, mutagenic lesions in the germline (up to 50%). Heritable ZFN-induced lesions in two independent lines produced truncated, nonfunctional CRY2 proteins, resulting in the in vivo disruption of circadian behavior and the molecular clock mechanism. Our work genetically defines CRY2 as an essential transcriptional repressor of the monarch circadian clock and provides a proof of concept for the use of ZFNs for manipulating genes in the monarch butterfly genome. Importantly, this approach could be used in other lepidopterans and “nonmodel” insects, thus opening new avenues to decipher the molecular underpinnings of a variety of biological processes. PMID:23009861

  19. Spatial Cognition and Range Use in Free-Range Laying Hens

    PubMed Central

    Campbell, Dana L. M.; Loh, Ziyang A.; Dyall, Tim R.; Lee, Caroline

    2018-01-01

    Simple Summary Individual free-range laying hens vary in their use of the outdoor range. The outdoor environment is typically more complex and variable than indoor housing and thus range use may be related to differences in spatial abilities. Individual adult hens that never went outside were slower to learn a T-maze task—which requires birds to repeatedly find a food reward in one arm of the maze, compared to outdoor-preferring hens. Pullets that were faster to learn the maze also showed more visits to the range in their first month of range access but only in one of two tested groups. Early enrichment improved learning of the maze but only when the birds were tested before onset of lay. Fear may play a role in inhibiting bird’s spatial learning and their range use. More studies of different enriched rearing treatments and their impacts on fear and learning would be needed to confirm these findings. Overall, these results contribute to our understanding of why some birds choose to never access the outdoor range area. Abstract Radio-frequency identification tracking shows individual free-range laying hens vary in range use, with some never going outdoors. The range is typically more environmentally complex, requiring navigation to return to the indoor resources. Outdoor-preferring hens may have improved spatial abilities compared to indoor-preferring hens. Experiment 1 tested 32 adult ISA Brown hens in a T-maze learning task that showed exclusively-indoor birds were slowest to reach the learning success criterion (p < 0.05). Experiment 2 tested 117 pullets from enriched or non-enriched early rearing treatments (1 pen replicate per treatment) in the same maze at 15–16 or 17–18 weeks. Enriched birds reached learning success criterion faster at 15–16 weeks (p < 0.05) but not at 17–18 weeks (p > 0.05), the age that coincided with the onset of lay. Enriched birds that were faster to learn the maze task showed more range visits in the first 4 weeks of range

  20. Healthcare Energy End-Use Monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheppy, M.; Pless, S.; Kung, F.

    NREL partnered with two hospitals (MGH and SUNY UMU) to collect data on the energy used for multiple thermal and electrical end-use categories, including preheat, heating, and reheat; humidification; service water heating; cooling; fans; pumps; lighting; and select plug and process loads. Additional data from medical office buildings were provided for an analysis focused on plug loads. Facility managers, energy managers, and engineers in the healthcare sector will be able to use these results to more effectively prioritize and refine the scope of investments in new metering and energy audits.

  1. Comparing phase-sensitive and phase-insensitive echolocation target images using a monaural audible sonar.

    PubMed

    Kuc, Roman

    2018-04-01

    This paper describes phase-sensitive and phase-insensitive processing of monaural echolocation waveforms to generate target maps. Composite waveforms containing both the emission and echoes are processed to estimate the target impulse response using an audible sonar. Phase-sensitive processing yields the composite signal envelope, while phase-insensitive processing that starts with the composite waveform power spectrum yields the envelope of the autocorrelation function. Analysis and experimental verification show that multiple echoes form an autocorrelation function that produces near-range phantom-reflector artifacts. These artifacts interfere with true target echoes when the first true echo occurs at a time that is less than the total duration of the target echoes. Initial comparison of phase-sensitive and phase-insensitive maps indicates that both display important target features, indicating that phase is not vital. A closer comparison illustrates the improved resolution of phase-sensitive processing, the near-range phantom-reflectors produced by phase-insensitive processing, and echo interference and multiple reflection artifacts that were independent of the processing.

  2. Use of a compact range approach to evaluate rf and dual-mode missiles

    NASA Astrophysics Data System (ADS)

    Willis, Kenneth E.; Weiss, Yosef

    2000-07-01

    This paper describes a hardware-in-the-loop (HWIL) system developed for testing Radio Frequency (RF), Infra-Red (IR), and Dual-Mode missile seekers. The system consists of a unique hydraulic five-axis (three seeker axes plus two target axes) Flight Motion Table (FMT), an off-axis parabolic reflector, and electronics required to generate the signals to the RF feeds. RF energy that simulates the target is fed into the reflector from three orthogonal feeds mounted on the inner target axis, at the focal point area of the parabolic reflector. The parabolic reflector, together with the three RF feeds (the Compact Range), effectively produces a far-field image of the target. Both FMT target axis motion and electronic control of the RF beams (deflection) modify the simulated line-of-sight target angles. Multiple targets, glint, multi-path, ECM, and clutter can be introduced electronically. To evaluate dual-mode seekers, the center section of the parabolic reflector is replaced with an IR- transparent, but RF-reflective section. An IR scene projector mounts to the FMT target axes, with its image focused on the intersection of the FMT seeker axes. The system eliminates the need for a large anechoic chamber and 'Target Wall' or target motion system used with conventional HWIL systems. This reduces acquisition and operating costs of the facility.

  3. Detection and laser ranging of orbital objects using optical methods

    NASA Astrophysics Data System (ADS)

    Wagner, P.; Hampf, D.; Sproll, F.; Hasenohr, T.; Humbert, L.; Rodmann, J.; Riede, W.

    2016-09-01

    Laser ranging to satellites (SLR) in earth orbit is an established technology used for geodesy, fundamental science and precise orbit determination. A combined active and passive optical measurement system using a single telescope mount is presented which performs precise ranging measurements of retro reflector equipped objects in low earth orbit (LEO). The German Aerospace Center (DLR) runs an observatory in Stuttgart where a system has been assembled completely from commercial off-the-shelf (COTS) components. The visible light directed to the tracking camera is used to perform angular measurements of objects under investigation. This is done astrometrically by comparing the apparent target position with cataloged star positions. First successful satellite laser ranging was demonstrated recently using an optical fiber directing laser pulses onto the astronomical mount. The transmitter operates at a wavelength of 1064 nm with a repetition rate of 3 kHz and pulse energy of 25 μJ. A motorized tip/tilt mount allows beam steering of the collimated beam with μrad accuracy. The returning photons reflected from the object in space are captured with the tracking telescope. A special low aberration beam splitter unit was designed to separate the infrared from visible light. This allows passive optical closed loop tracking and operation of a single photon detector for time of flight measurements at a single telescope simultaneously. The presented innovative design yields to a compact and cost effective but very precise ranging system which allows orbit determination.

  4. Slide Esophagoplasty vs End-to-End Anastomosis for Recalcitrant Esophageal Stricture after Esophageal Atresia Repair.

    PubMed

    Kamran, Ali; Smithers, Charles J; Manfredi, Michael A; Hamilton, Thomas E; Ngo, Peter D; Zurakowski, David; Jennings, Russell W

    2018-06-01

    Anastomotic stricture is a common complication after esophageal atresia (EA) repair. Patients with a recalcitrant stricture may require surgical intervention. The technique of reanastomosis after stricture resection can affect patient outcomes. Patients with EA who underwent anastomotic stricture resection, from July 2010 to February 2017, were reviewed. After stricture resection, patients who had slide esophagoplasty performed were compared with those having conventional end-to-end anastomosis. Fifty patients underwent stricture repair surgery by slide esophagoplasty (n = 12) or end-to-end (n = 38) anastomosis technique at a median age of 14 months (interquartile range [IQR] 6 to 23 months). Significantly fewer patients required dilation therapy after slide esophagoplasty: 6 of 12 (50%) compared with 32 of 38 (84%) in the end-to-end group (p = 0.02). The number of dilation sessions was significantly lower in the slide group vs the end-to-end (p = 0.004) group, with a risk ratio confirming the approximately half the number of dilations for the slide approach (risk ratio 0.57, 95% CI 0.38 to 0.86). Steroid injection was combined with dilation in 3 of 12 (25%) vs 22 of 38 (58%) in the slide and end-to-end groups, respectively (p = 0.10). Stent placement was used in none of slide cases vs 8 of 38 (21%) in the end-to-end group (p = 0.17). Stricture incision was performed in 1 of 12 (8%) in the slide group and 11 of 38 (29%) in the end-to-end group (p = 0.25). There were leak complications in fewer patients after slide esophagoplasty compared with end-to-end anastomosis: 1 of 12 (8%) vs 8 of 38 (21%) (p = 0.43). Slide esophagoplasty may be a useful technique of anastomotic configuration for selected patients with recalcitrant esophageal stricture, offering more favorable outcomes compared with end-to-end anastomosis. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  5. A multicentre 'end to end' dosimetry audit for cervix HDR brachytherapy treatment.

    PubMed

    Palmer, Antony L; Diez, Patricia; Gandon, Laura; Wynn-Jones, Andrea; Bownes, Peter; Lee, Chris; Aird, Edwin; Bidmead, Margaret; Lowe, Gerry; Bradley, David; Nisbet, Andrew

    2015-02-01

    To undertake the first multicentre fully 'end to end' dosimetry audit for HDR cervix brachytherapy, comparing planned and delivered dose distributions around clinical treatment applicators, with review of local procedures. A film-dosimetry audit was performed at 46 centres, including imaging, applicator reconstruction, treatment planning and delivery. Film dose maps were calculated using triple-channel dosimetry and compared to RTDose data from treatment planning systems. Deviations between plan and measurement were quantified at prescription Point A and using gamma analysis. Local procedures were also discussed. The mean difference between planned and measured dose at Point A was -0.6% for plastic applicators and -3.0% for metal applicators, at standard uncertainty 3.0% (k=1). Isodose distributions agreed within 1mm over a dose range 2-16Gy. Mean gamma passing rates exceeded 97% for plastic and metal applicators at 3% (local) 2mm criteria. Two errors were found: one dose normalisation error and one applicator library misaligned with the imaged applicator. Suggestions for quality improvement were also made. The concept of 'end to end' dosimetry audit for HDR brachytherapy has been successfully implemented in a multicentre environment, providing evidence that a high level of accuracy in brachytherapy dosimetry can be achieved. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Hybrid-denovo: a de novo OTU-picking pipeline integrating single-end and paired-end 16S sequence tags.

    PubMed

    Chen, Xianfeng; Johnson, Stephen; Jeraldo, Patricio; Wang, Junwen; Chia, Nicholas; Kocher, Jean-Pierre A; Chen, Jun

    2018-03-01

    Illumina paired-end sequencing has been increasingly popular for 16S rRNA gene-based microbiota profiling. It provides higher phylogenetic resolution than single-end reads due to a longer read length. However, the reverse read (R2) often has significant low base quality, and a large proportion of R2s will be discarded after quality control, resulting in a mixture of paired-end and single-end reads. A typical 16S analysis pipeline usually processes either paired-end or single-end reads but not a mixture. Thus, the quantification accuracy and statistical power will be reduced due to the loss of a large amount of reads. As a result, rare taxa may not be detectable with the paired-end approach, or low taxonomic resolution will result in a single-end approach. To have both the higher phylogenetic resolution provided by paired-end reads and the higher sequence coverage by single-end reads, we propose a novel OTU-picking pipeline, hybrid-denovo, that can process a hybrid of single-end and paired-end reads. Using high-quality paired-end reads as a gold standard, we show that hybrid-denovo achieved the highest correlation with the gold standard and performed better than the approaches based on paired-end or single-end reads in terms of quantifying the microbial diversity and taxonomic abundances. By applying our method to a rheumatoid arthritis (RA) data set, we demonstrated that hybrid-denovo captured more microbial diversity and identified more RA-associated taxa than a paired-end or single-end approach. Hybrid-denovo utilizes both paired-end and single-end 16S sequencing reads and is recommended for 16S rRNA gene targeted paired-end sequencing data.

  7. Automated segmentation of 3D anatomical structures on CT images by using a deep convolutional network based on end-to-end learning approach

    NASA Astrophysics Data System (ADS)

    Zhou, Xiangrong; Takayama, Ryosuke; Wang, Song; Zhou, Xinxin; Hara, Takeshi; Fujita, Hiroshi

    2017-02-01

    We have proposed an end-to-end learning approach that trained a deep convolutional neural network (CNN) for automatic CT image segmentation, which accomplished a voxel-wised multiple classification to directly map each voxel on 3D CT images to an anatomical label automatically. The novelties of our proposed method were (1) transforming the anatomical structures segmentation on 3D CT images into a majority voting of the results of 2D semantic image segmentation on a number of 2D-slices from different image orientations, and (2) using "convolution" and "deconvolution" networks to achieve the conventional "coarse recognition" and "fine extraction" functions which were integrated into a compact all-in-one deep CNN for CT image segmentation. The advantage comparing to previous works was its capability to accomplish real-time image segmentations on 2D slices of arbitrary CT-scan-range (e.g. body, chest, abdomen) and produced correspondingly-sized output. In this paper, we propose an improvement of our proposed approach by adding an organ localization module to limit CT image range for training and testing deep CNNs. A database consisting of 240 3D CT scans and a human annotated ground truth was used for training (228 cases) and testing (the remaining 12 cases). We applied the improved method to segment pancreas and left kidney regions, respectively. The preliminary results showed that the accuracies of the segmentation results were improved significantly (pancreas was 34% and kidney was 8% increased in Jaccard index from our previous results). The effectiveness and usefulness of proposed improvement for CT image segmentations were confirmed.

  8. RNA-guided genome editing for target gene mutations in wheat.

    PubMed

    Upadhyay, Santosh Kumar; Kumar, Jitesh; Alok, Anshu; Tuli, Rakesh

    2013-12-09

    The clustered, regularly interspaced, short palindromic repeats (CRISPR) and CRISPR-associated protein (Cas) system has been used as an efficient tool for genome editing. We report the application of CRISPR-Cas-mediated genome editing to wheat (Triticum aestivum), the most important food crop plant with a very large and complex genome. The mutations were targeted in the inositol oxygenase (inox) and phytoene desaturase (pds) genes using cell suspension culture of wheat and in the pds gene in leaves of Nicotiana benthamiana. The expression of chimeric guide RNAs (cgRNA) targeting single and multiple sites resulted in indel mutations in all the tested samples. The expression of Cas9 or sgRNA alone did not cause any mutation. The expression of duplex cgRNA with Cas9 targeting two sites in the same gene resulted in deletion of DNA fragment between the targeted sequences. Multiplexing the cgRNA could target two genes at one time. Target specificity analysis of cgRNA showed that mismatches at the 3' end of the target site abolished the cleavage activity completely. The mismatches at the 5' end reduced cleavage, suggesting that the off target effects can be abolished in vivo by selecting target sites with unique sequences at 3' end. This approach provides a powerful method for genome engineering in plants.

  9. Prediction, scenarios and insight: The uses of an end-to-end model

    NASA Astrophysics Data System (ADS)

    Steele, John H.

    2012-09-01

    A major function of ecosystem models is to provide extrapolations from observed data in terms of predictions or scenarios or insight. These models can be at various levels of taxonomic resolution such as total community production, abundance of functional groups, or species composition, depending on the data input as drivers. A 40-year dynamic simulation of end-to-end processes in the Georges Bank food web is used to illustrate the input/output relations and the insights gained at the three levels of food web aggregation. The focus is on the intermediate level and the longer term changes in three functional fish guilds - planktivores, benthivores and piscivores - in terms of three ecosystem-based metrics - nutrient input, relative productivity of plankton and benthos, and food intake by juvenile fish. These simulations can describe the long term constraints imposed on guild structure and productivity by energy fluxes over the 40 years but cannot explain concurrent switches in abundance of individual species within guilds. Comparing time series data for individual species with model output provides insights; but including the data in the model would confer only limited extra information. The advantages and limitations of the three levels of resolution of models in relation to ecosystem-based management are: The correlations between primary production and total yield of fish imply a “bottom-up” constraint on end-to-end energy flow through the food web that can provide predictions of such yields. Functionally defined metrics such as nutrient input, relative productivity of plankton and benthos and food intake by juvenile fish, represent bottom-up, mid-level and top-down forcing of the food web. Model scenarios using these metrics can demonstrate constraints on the productivity of these functionally defined guilds within the limits set by (1). Comparisons of guild simulations with time series of fish species provide insight into the switches in species dominance

  10. Measurements of Laser Imprint with High-Z Coated targets on Omega EP

    NASA Astrophysics Data System (ADS)

    Karasik, Max; Oh, J.; Stoeckl, C.; Aglitskiy, Y.; Schmitt, A. J.; Bates, J. W.; Obenschain, S. P.

    2015-11-01

    Previous experiments on Nike KrF laser (λ = 248nm) at NRL found that a thin (400-800 Å) high-Z (Au or Pd) overcoat on the laser side of the target is effective in suppressing broadband imprint and reducing ablative Richtmyer-Meshkov growth. The overcoat initially absorbs the laser and emits soft x-rays that ablate the target, forming a large stand-off distance between laser absorption and ablation and driving the target at higher mass ablation rate. Implementation of this technique on the frequency-tripled Nd:glass (351 nm) NIF would enable a wider range direct drive experiments there. To this end, we are carrying out experiments using the NIF-like beams of Omega EP. Analogous to experiments on Nike, areal mass perturbations due to RT-amplified laser imprint are measured using curved crystal imaging coupled to a streak camera. High-Z coating dynamics and target trajectory are imaged side-on. First results indicate that imprint suppression is observed, albeit with thicker coatings. Work supported by the Department of Energy/NNSA.

  11. Concepts for a Muon Accelerator Front-End

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stratakis, Diktys; Berg, Scott; Neuffer, David

    2017-03-16

    We present a muon capture front-end scheme for muon based applications. In this Front-End design, a proton bunch strikes a target and creates secondary pions that drift into a capture channel, decaying into muons. A series of rf cavities forms the resulting muon beams into a series of bunches of differerent energies, aligns the bunches to equal central energies, and initiates ionization cooling. We also discuss the design of a chicane system for the removal of unwanted secondary particles from the muon capture region and thus reduce activation of the machine. With the aid of numerical simulations we evaluate themore » performance of this Front-End scheme as well as study its sensitivity against key parameters such as the type of target, the number of rf cavities and the gas pressure of the channel.« less

  12. Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets

    PubMed Central

    Xiang, Yu; Lu, Yi

    2012-01-01

    Portable, low-cost and quantitative detection of a broad range of targets at home and in the field has the potential to revolutionize medical diagnostics and environmental monitoring. Despite many years of research, very few such devices are commercially available. Taking advantage of the wide availability and low cost of the pocket-sized personal glucose meter—used worldwide by diabetes sufferers—we demonstrate a method to use such meters to quantify non-glucose targets, ranging from a recreational drug (cocaine, 3.4 μM detection limit) to an important biological cofactor (adenosine, 18 μM detection limit), to a disease marker (interferon-gamma of tuberculosis, 2.6 nM detection limit) and a toxic metal ion (uranium, 9.1 nM detection limit). The method is based on the target-induced release of invertase from a functional-DNA–invertase conjugate. The released invertase converts sucrose into glucose, which is detectable using the meter. The approach should be easily applicable to the detection of many other targets through the use of suitable functional-DNA partners (aptamers DNAzymes or aptazymes). PMID:21860458

  13. Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets

    NASA Astrophysics Data System (ADS)

    Xiang, Yu; Lu, Yi

    2011-09-01

    Portable, low-cost and quantitative detection of a broad range of targets at home and in the field has the potential to revolutionize medical diagnostics and environmental monitoring. Despite many years of research, very few such devices are commercially available. Taking advantage of the wide availability and low cost of the pocket-sized personal glucose meter—used worldwide by diabetes sufferers—we demonstrate a method to use such meters to quantify non-glucose targets, ranging from a recreational drug (cocaine, 3.4 µM detection limit) to an important biological cofactor (adenosine, 18 µM detection limit), to a disease marker (interferon-gamma of tuberculosis, 2.6 nM detection limit) and a toxic metal ion (uranium, 9.1 nM detection limit). The method is based on the target-induced release of invertase from a functional-DNA-invertase conjugate. The released invertase converts sucrose into glucose, which is detectable using the meter. The approach should be easily applicable to the detection of many other targets through the use of suitable functional-DNA partners (aptamers, DNAzymes or aptazymes).

  14. STAR Au + Au Fixed Target Results

    NASA Astrophysics Data System (ADS)

    Meehan, Kathryn; STAR Collaboration

    2015-10-01

    The RHIC Beam Energy Scan (BES) program was proposed to look for the turn-off of signatures of the quark gluon plasma (QGP), search for a possible QCD critical point, and study the nature of the phase transition between hadronic and partonic matter. The results from the NA49 experiment at CERN have been used to claim that the onset of deconfinement occurs at a collision energy around a center-of-mass energy of 7 GeV, the low end of the BES range. Data from lower energies are needed to test if this onset occurs. The goal of the STAR Fixed-Target Program is to extend the collision energy range in BES II with the same detector to energies that are likely below the onset of deconfinement. Currently, STAR has inserted a gold target into the beam pipe and conducted test runs at center-of-mass energies 3.9 and 4.5 GeV. Tests have been done with both Au and Al beams. First physics results from a Coulomb analysis of Au + Au fixed-target collisions, which are found to be consistent with previous experiments, will be presented. These results demonstrate that STAR has good particle identification capabilities in this novel detector setup. Furthermore, the Coulomb potential, which is sensitive to the Z of the projectile and degree of baryonic stopping, will be compared with published results from the AGS. This material is based upon work supported by the National Science Foundation under Grant No. 1068833.

  15. Targeted Capture Sequencing in Whitebark Pine Reveals Range-Wide Demographic and Adaptive Patterns Despite Challenges of a Large, Repetitive Genome.

    PubMed

    Syring, John V; Tennessen, Jacob A; Jennings, Tara N; Wegrzyn, Jill; Scelfo-Dalbey, Camille; Cronn, Richard

    2016-01-01

    Whitebark pine (Pinus albicaulis) inhabits an expansive range in western North America, and it is a keystone species of subalpine environments. Whitebark is susceptible to multiple threats - climate change, white pine blister rust, mountain pine beetle, and fire exclusion - and it is suffering significant mortality range-wide, prompting the tree to be listed as 'globally endangered' by the International Union for Conservation of Nature and 'endangered' by the Canadian government. Conservation collections (in situ and ex situ) are being initiated to preserve the genetic legacy of the species. Reliable, transferrable, and highly variable genetic markers are essential for quantifying the genetic profiles of seed collections relative to natural stands, and ensuring the completeness of conservation collections. We evaluated the use of hybridization-based target capture to enrich specific genomic regions from the 27 GB genome of whitebark pine, and to evaluate genetic variation across loci, trees, and geography. Probes were designed to capture 7,849 distinct genes, and screening was performed on 48 trees. Despite the inclusion of repetitive elements in the probe pool, the resulting dataset provided information on 4,452 genes and 32% of targeted positions (528,873 bp), and we were able to identify 12,390 segregating sites from 47 trees. Variations reveal strong geographic trends in heterozygosity and allelic richness, with trees from the southern Cascade and Sierra Range showing the greatest distinctiveness and differentiation. Our results show that even under non-optimal conditions (low enrichment efficiency; inclusion of repetitive elements in baits), targeted enrichment produces high quality, codominant genotypes from large genomes. The resulting data can be readily integrated into management and gene conservation activities for whitebark pine, and have the potential to be applied to other members of 5-needle pine group (Pinus subsect. Quinquefolia) due to their

  16. CT scan range estimation using multiple body parts detection: let PACS learn the CT image content.

    PubMed

    Wang, Chunliang; Lundström, Claes

    2016-02-01

    The aim of this study was to develop an efficient CT scan range estimation method that is based on the analysis of image data itself instead of metadata analysis. This makes it possible to quantitatively compare the scan range of two studies. In our study, 3D stacks are first projected to 2D coronal images via a ray casting-like process. Trained 2D body part classifiers are then used to recognize different body parts in the projected image. The detected candidate regions go into a structure grouping process to eliminate false-positive detections. Finally, the scale and position of the patient relative to the projected figure are estimated based on the detected body parts via a structural voting. The start and end lines of the CT scan are projected to a standard human figure. The position readout is normalized so that the bottom of the feet represents 0.0, and the top of the head is 1.0. Classifiers for 18 body parts were trained using 184 CT scans. The final application was tested on 136 randomly selected heterogeneous CT scans. Ground truth was generated by asking two human observers to mark the start and end positions of each scan on the standard human figure. When compared with the human observers, the mean absolute error of the proposed method is 1.2% (max: 3.5%) and 1.6% (max: 5.4%) for the start and end positions, respectively. We proposed a scan range estimation method using multiple body parts detection and relative structure position analysis. In our preliminary tests, the proposed method delivered promising results.

  17. Tolerance analysis of null lenses using an end-use system performance criterion

    NASA Astrophysics Data System (ADS)

    Rodgers, J. Michael

    2000-07-01

    An effective method of assigning tolerances to a null lens is to determine the effects of null-lens fabrication and alignment errors on the end-use system itself, not simply the null lens. This paper describes a method to assign null- lens tolerances based on their effect on any performance parameter of the end-use system.

  18. Demonstration of a fully-coupled end-to-end model for small pelagic fish using sardine and anchovy in the California Current

    NASA Astrophysics Data System (ADS)

    Rose, Kenneth A.; Fiechter, Jerome; Curchitser, Enrique N.; Hedstrom, Kate; Bernal, Miguel; Creekmore, Sean; Haynie, Alan; Ito, Shin-ichi; Lluch-Cota, Salvador; Megrey, Bernard A.; Edwards, Chris A.; Checkley, Dave; Koslow, Tony; McClatchie, Sam; Werner, Francisco; MacCall, Alec; Agostini, Vera

    2015-11-01

    We describe and document an end-to-end model of anchovy and sardine population dynamics in the California Current as a proof of principle that such coupled models can be developed and implemented. The end-to-end model is 3-dimensional, time-varying, and multispecies, and consists of four coupled submodels: hydrodynamics, Eulerian nutrient-phytoplankton-zooplankton (NPZ), an individual-based full life cycle anchovy and sardine submodel, and an agent-based fishing fleet submodel. A predator roughly mimicking albacore was included as individuals that consumed anchovy and sardine. All submodels were coded within the ROMS open-source community model, and used the same resolution spatial grid and were all solved simultaneously to allow for possible feedbacks among the submodels. We used a super-individual approach and solved the coupled models on a distributed memory parallel computer, both of which created challenging but resolvable bookkeeping challenges. The anchovy and sardine growth, mortality, reproduction, and movement, and the fishing fleet submodel, were each calibrated using simplified grids before being inserted into the full end-to-end model. An historical simulation of 1959-2008 was performed, and the latter 45 years analyzed. Sea surface height (SSH) and sea surface temperature (SST) for the historical simulation showed strong horizontal gradients and multi-year scale temporal oscillations related to various climate indices (PDO, NPGO), and both showed responses to ENSO variability. Simulated total phytoplankton was lower during strong El Nino events and higher for the strong 1999 La Nina event. The three zooplankton groups generally corresponded to the spatial and temporal variation in simulated total phytoplankton. Simulated biomasses of anchovy and sardine were within the historical range of observed biomasses but predicted biomasses showed much less inter-annual variation. Anomalies of annual biomasses of anchovy and sardine showed a switch in the mid

  19. Treatment Optimization Using Computed Tomography-Delineated Targets Should be Used for Supraclavicular Irradiation for Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liengsawangwong, Raweewan; Yu, T.-K.; Sun, T.-L.

    2007-11-01

    Background: The purpose of this study was to determine whether the use of optimized CT treatment planning offered better coverage of axillary level III (LIII)/supraclavicular (SC) targets than the empirically derived dose prescription that are commonly used. Materials/Methods: Thirty-two consecutive breast cancer patients who underwent CT treatment planning of a SC field were evaluated. Each patient was categorized according to body mass index (BMI) classes: normal, overweight, or obese. The SC and LIII nodal beds were contoured, and four treatment plans for each patient were generated. Three of the plans used empiric dose prescriptions, and these were compared with amore » CT-optimized plan. Each plan was evaluated by two criteria: whether 98% of target volume receive >90% of prescribed dose and whether < 5% of the irradiated volume received 105% of prescribed dose. Results: The mean depth of SC and LIII were 3.2 cm (range, 1.4-6.7 cm) and 3.1 (range, 1.7-5.8 cm). The depth of these targets varied according across BMI classes (p = 0.01). Among the four sets of plans, the CT-optimized plans were the most successful at achieving both of the dosimetry objectives for every BMI class (normal BMI, p = .003; overweight BMI, p < .0001; obese BMI, p < .001). Conclusions: Across all BMI classes, routine radiation prescriptions did not optimally cover intended targets for every patient. Optimized CT-based treatment planning generated the most successful plans; therefore, we recommend the use of routine CT simulation and treatment planning of SC fields in breast cancer.« less

  20. NIMROD: The Near and InterMediate Range Order Diffractometer of the ISIS second target station.

    PubMed

    Bowron, D T; Soper, A K; Jones, K; Ansell, S; Birch, S; Norris, J; Perrott, L; Riedel, D; Rhodes, N J; Wakefield, S R; Botti, A; Ricci, M-A; Grazzi, F; Zoppi, M

    2010-03-01

    NIMROD is the Near and InterMediate Range Order Diffractometer of the ISIS second target station. Its design is optimized for structural studies of disordered materials and liquids on a continuous length scale that extends from the atomic, upward of 30 nm, while maintaining subatomic distance resolution. This capability is achieved by matching a low and wider angle array of high efficiency neutron scintillation detectors to the broad band-pass radiation delivered by a hybrid liquid water and liquid hydrogen neutron moderator assembly. The capabilities of the instrument bridge the gap between conventional small angle neutron scattering and wide angle diffraction through the use of a common calibration procedure for the entire length scale. This allows the instrument to obtain information on nanoscale systems and processes that are quantitatively linked to the local atomic and molecular order of the materials under investigation.

  1. Cinacalcet: a pharmacoeconomic review of its use in secondary hyperparathyroidism in end-stage renal disease.

    PubMed

    Plosker, Greg L

    2011-09-01

    This article provides an overview of the clinical profile of the calcimimetic agent cinacalcet (Mimpara®, Sensipar®) in the treatment of patients with secondary hyperparathyroidism (SHPT) undergoing dialysis for end-stage renal disease (ESRD), followed by a comprehensive review of pharmacoeconomic analyses with cinacalcet in this patient population. Most patients with ESRD undergoing dialysis develop SHPT, which is associated with disturbances in bone mineral metabolism and the development of fractures, cardiovascular disease and other clinical events. Standard treatment of SHPT includes phosphate binders and active vitamin D derivatives. However, standard treatment alone seldom achieves recommended target plasma or serum levels of parathyroid hormone (PTH), calcium and phosphorous. The addition of cinacalcet to standard therapy in patients with SHPT undergoing dialysis for ESRD improves the likelihood of achieving target biochemical levels compared with standard therapy alone. On the basis of association studies, improvements in these intermediate endpoints are likely to reduce the risk of clinical events, such as fractures and cardiovascular disease. Therefore, part of the acquisition cost of cinacalcet is likely to be offset by reductions in other healthcare resource use, such as reductions in costs associated with a lower likelihood of clinical events, as well as potential reductions in dosages of standard treatment. A number of pharmacoeconomic analyses across various country settings indicate that cinacalcet plus standard therapy is cost effective relative to standard therapy alone if dialysis costs are excluded, or that early initiation of cinacalcet is cost effective compared with delaying cinacalcet treatment until PTH levels become very uncontrolled. However, across analyses with cinacalcet, results were variable and not always favourable. This wide range of results stems from differences in selection of data sources used to populate the models

  2. Automated target recognition using passive radar and coordinated flight models

    NASA Astrophysics Data System (ADS)

    Ehrman, Lisa M.; Lanterman, Aaron D.

    2003-09-01

    Rather than emitting pulses, passive radar systems rely on illuminators of opportunity, such as TV and FM radio, to illuminate potential targets. These systems are particularly attractive since they allow receivers to operate without emitting energy, rendering them covert. Many existing passive radar systems estimate the locations and velocities of targets. This paper focuses on adding an automatic target recognition (ATR) component to such systems. Our approach to ATR compares the Radar Cross Section (RCS) of targets detected by a passive radar system to the simulated RCS of known targets. To make the comparison as accurate as possible, the received signal model accounts for aircraft position and orientation, propagation losses, and antenna gain patterns. The estimated positions become inputs for an algorithm that uses a coordinated flight model to compute probable aircraft orientation angles. The Fast Illinois Solver Code (FISC) simulates the RCS of several potential target classes as they execute the estimated maneuvers. The RCS is then scaled by the Advanced Refractive Effects Prediction System (AREPS) code to account for propagation losses that occur as functions of altitude and range. The Numerical Electromagnetic Code (NEC2) computes the antenna gain pattern, so that the RCS can be further scaled. The Rician model compares the RCS of the illuminated aircraft with those of the potential targets. This comparison results in target identification.

  3. Comparison of Direct Side-to-End and End-to-End Hypoglossal-Facial Anastomosis for Facial Nerve Repair.

    PubMed

    Samii, Madjid; Alimohamadi, Maysam; Khouzani, Reza Karimi; Rashid, Masoud Rafizadeh; Gerganov, Venelin

    2015-08-01

    The hypoglossal facial anastomosis (HFA) is the gold standard for facial reanimation in patients with severe facial nerve palsy. The major drawbacks of the classic HFA technique are lingual morbidities due to hypoglossal nerve transection. The side-to-end HFA is a modification of the classic technique with fewer tongue-related morbidities. In this study we compared the outcome of the classic end-to-end and the direct side-to-end HFA surgeries performed at our center in regards to the facial reanimation success rate and tongue-related morbidities. Twenty-six successive cases of HFA were enrolled. In 9 of them end-to-end anastomoses were performed, and 17 had direct side-to-end anastomoses. The House-Brackmann (HB) and Pitty and Tator (PT) scales were used to document surgical outcome. The hemiglossal atrophy, swallowing, and hypoglossal nerve function were assessed at follow-up. The original pathology was vestibular schwannoma in 15, meningioma in 4, brain stem glioma in 4, and other pathologies in 3. The mean interval between facial palsy and HFA was 18 months (range: 0-60). The median follow-up period was 20 months. The PT grade at follow-up was worse in patients with a longer interval from facial palsy and HFA (P value: 0.041). The lesion type was the only other factor that affected PT grade (the best results in vestibular schwannoma and the worst in the other pathologies group, P value: 0.038). The recovery period for facial tonicity was longer in patients with radiation therapy before HFA (13.5 vs. 8.5 months) and those with a longer than 2-year interval from facial palsy to HFA (13.5 vs. 8.5 months). Although no significant difference between the side-to-end and the end-to-end groups was seen in terms of facial nerve functional recovery, patients from the side-to-end group had a significantly lower rate of lingual morbidities (tongue hemiatrophy: 100% vs. 5.8%, swallowing difficulty: 55% vs. 11.7%, speech disorder 33% vs. 0%). With the side-to-end HFA

  4. Transmission of 100-MHz-range ultrasound through a fused quartz fiber.

    PubMed

    Irie, Takasuke; Tagawa, Norio; Tanabe, Masayuki; Moriya, Tadashi; Yoshizawa, Masasumi; Iijima, Takashi; Itoh, Kouichi; Yokoyama, Taku; Kumagai, Hideki; Taniguchi, Nobuyuki

    2011-07-01

    This paper describes an investigation into direct observation of microscopic images of tissue using a thin acoustic wave guide. First, the characteristics of the ultrasonic wave propagated in a fused quartz fiber were measured using the reflection method in order to study the insertion loss and the frequency shift of the ultrasonic wave transmitted from the transducer. Next, a receiving transducer was placed close to the end of the fiber, and the characteristics of the ultrasonic waves propagated through the acoustic coupling medium were measured using the penetration method in order to study the insertion loss and the frequency-dependent attenuation of the penetrated waves. Finally, a C-mode image was obtained by optimizing the measuring conditions using the results of the above measurements and scanning the ultrasonic beams on a target (coin) in water. A reflected wave with a peak frequency of approximately 220 MHz was obtained from the end of the fiber. The transmitted ultrasonic waves propagated through the acoustic coupling medium were detected with a frequency range of approximately 125-170 MHz, and the maximum detectable distance of the waves was approximately 1.2 mm within the 100-MHz frequency range. Finally, a high-frequency C-mode image of a coin in water was obtained using a tapered fused quartz fiber. The results suggest that it is necessary to improve the signal-to-noise ratio and reduce the insertion loss in the experimental system in order to make it possible to obtain microscopic images of tissue.

  5. Identifying the cellular targets of natural products using T7 phage display.

    PubMed

    Piggott, Andrew M; Karuso, Peter

    2016-05-04

    Covering: up to the end of 2015While Nature continues to deliver a myriad of potent and structurally diverse biologically active small molecules, the cellular targets and modes of action of these natural products are rarely identified, significantly hindering their development as new chemotherapeutic agents. This article provides an introductory tutorial on the use of T7 phage display as a tool to rapidly identify the cellular targets of natural products and is aimed specifically at natural products chemists who may have only limited experience in molecular biology. A brief overview of T7 phage display is provided, including its strengths, weaknesses, and the type of problems that can and cannot be tackled with this technology. Affinity probe construction is reviewed, including linker design and natural product derivatisation strategies. A detailed description of the T7 phage biopanning procedure is provided, with valuable tips for optimising each step in the process, as well as advice for identifying and avoiding the most commonly encountered challenges and pitfalls along the way. Finally, a brief discussion is provided on techniques for validating the cellular targets identified using T7 phage display.

  6. Results from Solar Reflective Band End-to-End Testing for VIIRS F1 Sensor Using T-SIRCUS

    NASA Technical Reports Server (NTRS)

    McIntire, Jeff; Moyer, David; McCarthy, James K.; DeLuccia, Frank; Xiong, Xiaoxiong; Butler, James J.; Guenther, Bruce

    2011-01-01

    Verification of the Visible Infrared Imager Radiometer Suite (VIIRS) End-to-End (E2E) sensor calibration is highly recommended before launch, to identify any anomalies and to improve our understanding of the sensor on-orbit calibration performance. E2E testing of the Reflective Solar Bands (RSB) calibration cycle was performed pre-launch for the VIIRS Fight 1 (F1) sensor at the Ball Aerospace facility in Boulder CO in March 2010. VIIRS reflective band calibration cycle is very similar to heritage sensor MODIS in that solar illumination, via a diffuser, is used to correct for temporal variations in the instrument responsivity. Monochromatic light from the NIST T-SIRCUS was used to illuminate both the Earth View (EV), via an integrating sphere, and the Solar Diffuser (SD) view, through a collimator. The collimator illumination was cycled through a series of angles intended to simulate the range of possible angles for which solar radiation will be incident on the solar attenuation screen on-orbit. Ideally, the measured instrument responsivity (defined here as the ratio of the detector response to the at-sensor radiance) should be the same whether the EV or SD view is illuminated. The ratio of the measured responsivities was determined at each collimator angle and wavelength. In addition, the Solar Diffuser Stability Monitor (SDSM), a ratioing radiometer designed to track the temporal variation in the SD BRF by direct comparison to solar radiation, was illuminated by the collimator. The measured SDSM ratio was compared to the predicted ratio. An uncertainty analysis was also performed on both the SD and SDSM calibrations.

  7. The N-end rule pathway and regulation by proteolysis

    PubMed Central

    Varshavsky, Alexander

    2011-01-01

    The N-end rule relates the regulation of the in vivo half-life of a protein to the identity of its N-terminal residue. Degradation signals (degrons) that are targeted by the N-end rule pathway include a set called N-degrons. The main determinant of an N-degron is a destabilizing N-terminal residue of a protein. In eukaryotes, the N-end rule pathway is a part of the ubiquitin system and consists of two branches, the Ac/N-end rule and the Arg/N-end rule pathways. The Ac/N-end rule pathway targets proteins containing Nα-terminally acetylated (Nt-acetylated) residues. The Arg/N-end rule pathway recognizes unacetylated N-terminal residues and involves N-terminal arginylation. Together, these branches target for degradation a majority of cellular proteins. For example, more than 80% of human proteins are cotranslationally Nt-acetylated. Thus, most proteins harbor a specific degradation signal, termed AcN-degron, from the moment of their birth. Specific N-end rule pathways are also present in prokaryotes and in mitochondria. Enzymes that produce N-degrons include methionine-aminopeptidases, caspases, calpains, Nt-acetylases, Nt-amidases, arginyl-transferases, and leucyl-transferases. Regulated degradation of specific proteins by the N-end rule pathway mediates a legion of physiological functions, including the sensing of heme, oxygen, and nitric oxide; selective elimination of misfolded proteins; the regulation of DNA repair, segregation, and condensation; the signaling by G proteins; the regulation of peptide import, fat metabolism, viral and bacterial infections, apoptosis, meiosis, spermatogenesis, neurogenesis, and cardiovascular development; and the functioning of adult organs, including the pancreas and the brain. Discovered 25 years ago, this pathway continues to be a fount of biological insights. PMID:21633985

  8. Electronic Nicotine Delivery Systems (ENDS): What Nurses Need to Know.

    PubMed

    Essenmacher, Carol; Naegle, Madeline; Baird, Carolyn; Vest, Bridgette; Spielmann, Rene; Smith-East, Marie; Powers, Leigh

    Efforts to decrease adverse effects of tobacco use are affected by emergence of new nicotine delivery products. Advertising, product promotion, and social media promote use of these products, yet a lack of evidence regarding safety leaves nurses unprepared to counsel patients. To critically evaluate current research, reviews of literature, expert opinion, and stakeholder policy proposals on use and safety of electronic nicotine delivery systems (ENDS). A targeted examination of literature generated by key stakeholders and subject matter experts was conducted using key words, modified by risk factors, and limited to the past 8 years. Current knowledge gaps in research literature and practice implications of the literature are discussed. The safety of ENDS is questionable and unclear. There are clear health risks of nicotine exposure to developing brains. Potential health risks of ENDS secondhand emissions exposure exist. Using ENDS to facilitate total tobacco cessation is not proven.

  9. Method and apparatus for coherent burst ranging

    DOEpatents

    Wachter, Eric A.; Fisher, Walter G.

    1998-01-01

    A high resolution ranging method is described utilizing a novel modulated waveform, hereafter referred to as coherent burst modulation. In the coherent burst method, high frequency modulation of an acoustic or electromagnetic transmitter, such as a laser, is performed at a modulation frequency. This modulation frequency is transmitted quasi-continuously in the form of interrupted bursts of radiation. Energy from the transmitter is directed onto a target, interacts with the target, and the returning energy is collected. The encoded burst pattern contained in the collected return signal is detected coherently by a receiver that is tuned so as to be principally sensitive to the modulation frequency. The receiver signal is processed to determine target range using both time-of-flight of the burst envelope and phase shift of the high frequency modulation. This approach effectively decouples the maximum unambiguous range and range resolution relationship of earlier methods, thereby allowing high precision ranging to be conducted at arbitrarily long distances using at least one burst of encoded energy. The use of a receiver tuned to the high frequency modulation contained within the coherent burst vastly improves both sensitivity in the detection of the target return signal and rejection of background interferences, such as ambient acoustic or electromagnetic noise. Simultaneous transmission at several energies (or wavelengths) is possible by encoding each energy with a separate modulation frequency or pattern; electronic demodulation at the receiver allows the return pattern for each energy to be monitored independently. Radial velocity of a target can also be determined by monitoring change in phase shift of the return signal as a function of time.

  10. Method and apparatus for coherent burst ranging

    DOEpatents

    Wachter, E.A.; Fisher, W.G.

    1998-04-28

    A high resolution ranging method is described utilizing a novel modulated waveform, hereafter referred to as coherent burst modulation. In the coherent burst method, high frequency modulation of an acoustic or electromagnetic transmitter, such as a laser, is performed at a modulation frequency. This modulation frequency is transmitted quasi-continuously in the form of interrupted bursts of radiation. Energy from the transmitter is directed onto a target, interacts with the target, and the returning energy is collected. The encoded burst pattern contained in the collected return signal is detected coherently by a receiver that is tuned so as to be principally sensitive to the modulation frequency. The receiver signal is processed to determine target range using both time-of-flight of the burst envelope and phase shift of the high frequency modulation. This approach effectively decouples the maximum unambiguous range and range resolution relationship of earlier methods, thereby allowing high precision ranging to be conducted at arbitrarily long distances using at least one burst of encoded energy. The use of a receiver tuned to the high frequency modulation contained within the coherent burst vastly improves both sensitivity in the detection of the target return signal and rejection of background interferences, such as ambient acoustic or electromagnetic noise. Simultaneous transmission at several energies (or wavelengths) is possible by encoding each energy with a separate modulation frequency or pattern; electronic demodulation at the receiver allows the return pattern for each energy to be monitored independently. Radial velocity of a target can also be determined by monitoring change in phase shift of the return signal as a function of time. 12 figs.

  11. Range parameters of slow gold ions implanted into light targets

    NASA Astrophysics Data System (ADS)

    Kuzmin, V.

    2009-08-01

    Interatomic potentials for Au-C, Au-B, Au-N and Au-Si systems, calculated with density-functional theory (DFT) methods, have been used to evaluate the range parameters of gold in B, Si, BN and SiC films at energies of about 10-400 keV. The potentials have been employed to describe scattering angles of a projectile and to calculate the nuclear stopping powers and the higher moments of the energy, transferred in single collisions. Utilizing these findings the range parameters have been obtained by the standard transport theory and by Monte-Carlo simulations. A velocity proportional electronic stopping was included into the consideration. The approach developed corresponds completely to the standard classical scheme of the calculation of range parameters. Good agreement between the computed range parameters and available experimental data allow us to conclude that correlation effects between the nuclear and electronic stopping can be neglected in the energy range in question. Moreover, it is proven for the first time that the model by Grande, et al. [P.L. Grande, F.C. Zawislak, D. Fink, M. Behar, Nucl. Instr. and Meth. B 61 (1991) 282], which relies on the importance of correlation effects, contains inherent contradictions.

  12. Two-way laser ranging and time transfer experiments between LOLA and an Earth-based satellite laser ranging station

    NASA Astrophysics Data System (ADS)

    Mao, D.; Sun, X.; Neumann, G. A.; Barker, M. K.; Mazarico, E. M.; Hoffman, E.; Zagwodzki, T. W.; Torrence, M. H.; Mcgarry, J.; Smith, D. E.; Zuber, M. T.

    2017-12-01

    Satellite Laser Ranging (SLR) has established time-of-flight measurements with mm precision to targets orbiting the Earth and the Moon using single-ended round-trip laser ranging to passive optical retro-reflectors. These high-precision measurements enable advances in fundamental physics, solar system dynamics. However, the received signal strength suffers from a 1/R4 decay, which makes it impractical for measuring distances beyond the Moon's orbit. On the other hand, for a two-way laser transponder pair, where laser pulses are both transmitted to and received from each end of the laser links, the signal strength at both terminals only decreases by 1/R2, thus allowing a greater range of distances to be covered. The asynchronous transponder concept has been previously demonstrated by a test in 2005 between the Mercury Laser Altimeter (MLA) aboard the MESSENGER (MErcury Surface, Space ENvironment, Geochemistry, and Ranging) spacecraft and NASA's Goddard Geophysical and Astronomical Observatory (GGAO) at a distance of ˜0.16 AU. In October 2013, regular two-way transponder-type range measurements were obtained over 15 days between the Lunar Laser Communication Demonstration (LLCD) aboard the Lunar Atmosphere and Dust Environment Explorer (LADEE) spacecraft and NASA's ground station at White Sands, NM. The Lunar Orbiter Laser Altimeter (LOLA) aboard the Lunar Reconnaissance Orbiter (LRO) provides us a unique capability to test time-transfer beyond near Earth orbit. Here we present results from two-way transponder-type experiments between LOLA and GGAO conducted in March 2014 and 2017. As in the time-transfer by laser link (T2L2) experiments between a ground station and an earth-orbiting satellite, LOLA and GGAO ranged to each other simultaneously in these two-way tests at lunar distance. We measured the time-of-flight while cross-referencing the spacecraft clock to the ground station time. On May 4th, 2017, about 20 minutes of two-way measurements were collected. The

  13. DEF: an automated dead-end filling approach based on quasi-endosymbiosis.

    PubMed

    Liu, Lili; Zhang, Zijun; Sheng, Taotao; Chen, Ming

    2017-02-01

    Gap filling for the reconstruction of metabolic networks is to restore the connectivity of metabolites via finding high-confidence reactions that could be missed in target organism. Current methods for gap filling either fall into the network topology or have limited capability in finding missing reactions that are indirectly related to dead-end metabolites but of biological importance to the target model. We present an automated dead-end filling (DEF) approach, which is derived from the wisdom of endosymbiosis theory, to fill gaps by finding the most efficient dead-end utilization paths in a constructed quasi-endosymbiosis model. The recalls of reactions and dead ends of DEF reach around 73% and 86%, respectively. This method is capable of finding indirectly dead-end-related reactions with biological importance for the target organism and is applicable to any given metabolic model. In the E. coli iJR904 model, for instance, about 42% of the dead-end metabolites were fixed by our proposed method. DEF is publicly available at http://bis.zju.edu.cn/DEF/. mchen@zju.edu.cn Supplementary data are available at Bioinformatics online.

  14. End-to-end simulation of bunch merging for a muon collider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bao, Yu; Stratakis, Diktys; Hanson, Gail G.

    2015-05-03

    Muon accelerator beams are commonly produced indirectly through pion decay by interaction of a charged particle beam with a target. Efficient muon capture requires the muons to be first phase-rotated by rf cavities into a train of 21 bunches with much reduced energy spread. Since luminosity is proportional to the square of the number of muons per bunch, it is crucial for a Muon Collider to use relatively few bunches with many muons per bunch. In this paper we will describe a bunch merging scheme that should achieve this goal. We present for the first time a complete end-to-end simulationmore » of a 6D bunch merger for a Muon Collider. The 21 bunches arising from the phase-rotator, after some initial cooling, are merged in longitudinal phase space into seven bunches, which then go through seven paths with different lengths and reach the final collecting "funnel" at the same time. The final single bunch has a transverse and a longitudinal emittance that matches well with the subsequent 6D rectilinear cooling scheme.« less

  15. Detection range enhancement using circularly polarized light in scattering environments for infrared wavelengths

    DOE PAGES

    van der Laan, J. D.; Sandia National Lab.; Scrymgeour, D. A.; ...

    2015-03-13

    We find for infrared wavelengths there are broad ranges of particle sizes and refractive indices that represent fog and rain where the use of circular polarization can persist to longer ranges than linear polarization. Using polarization tracking Monte Carlo simulations for varying particle size, wavelength, and refractive index, we show that for specific scene parameters circular polarization outperforms linear polarization in maintaining the intended polarization state for large optical depths. This enhancement with circular polarization can be exploited to improve range and target detection in obscurant environments that are important in many critical sensing applications. Specifically, circular polarization persists bettermore » than linear for radiation fog in the short-wave infrared, for advection fog in the short-wave infrared and the long-wave infrared, and large particle sizes of Sahara dust around the 4 micron wavelength.« less

  16. Robust through-the-wall radar image classification using a target-model alignment procedure.

    PubMed

    Smith, Graeme E; Mobasseri, Bijan G

    2012-02-01

    A through-the-wall radar image (TWRI) bears little resemblance to the equivalent optical image, making it difficult to interpret. To maximize the intelligence that may be obtained, it is desirable to automate the classification of targets in the image to support human operators. This paper presents a technique for classifying stationary targets based on the high-range resolution profile (HRRP) extracted from 3-D TWRIs. The dependence of the image on the target location is discussed using a system point spread function (PSF) approach. It is shown that the position dependence will cause a classifier to fail, unless the image to be classified is aligned to a classifier-training location. A target image alignment technique based on deconvolution of the image with the system PSF is proposed. Comparison of the aligned target images with measured images shows the alignment process introducing normalized mean squared error (NMSE) ≤ 9%. The HRRP extracted from aligned target images are classified using a naive Bayesian classifier supported by principal component analysis. The classifier is tested using a real TWRI of canonical targets behind a concrete wall and shown to obtain correct classification rates ≥ 97%. © 2011 IEEE

  17. Target discrimination strategies in optics detection

    NASA Astrophysics Data System (ADS)

    Sjöqvist, Lars; Allard, Lars; Henriksson, Markus; Jonsson, Per; Pettersson, Magnus

    2013-10-01

    Detection and localisation of optical assemblies used for weapon guidance or sniper rifle scopes has attracted interest for security and military applications. Typically a laser system is used to interrogate a scene of interest and the retro-reflected radiation is detected. Different system approaches for area coverage can be realised ranging from flood illumination to step-and-stare or continuous scanning schemes. Independently of the chosen approach target discrimination is a crucial issue, particularly if a complex scene such as in an urban environment and autonomous operation is considered. In this work target discrimination strategies in optics detection are discussed. Typical parameters affecting the reflected laser radiation from the target are the wavelength, polarisation properties, temporal effects and the range resolution. Knowledge about the target characteristics is important to predict the target discrimination capability. Two different systems were used to investigate polarisation properties and range resolution information from targets including e.g. road signs, optical reflexes, rifle sights and optical references. The experimental results and implications on target discrimination will be discussed. If autonomous operation is required target discrimination becomes critical in order to reduce the number of false alarms.

  18. Uncovering novel repositioning opportunities using the Open Targets platform.

    PubMed

    Khaladkar, Mugdha; Koscielny, Gautier; Hasan, Samiul; Agarwal, Pankaj; Dunham, Ian; Rajpal, Deepak; Sanseau, Philippe

    2017-12-01

    The recently developed Open Targets platform consolidates a wide range of comprehensive evidence associating known and potential drug targets with human diseases. We have harnessed the integrated data from this platform for novel drug repositioning opportunities. Our computational workflow systematically mines data from various evidence categories and presents potential repositioning opportunities for drugs that are marketed or being investigated in ongoing human clinical trials, based on evidence strength on target-disease pairing. We classified these novel target-disease opportunities in several ways: (i) number of independent counts of evidence; (ii) broad therapy area of origin; and (iii) repositioning within or across therapy areas. Finally, we elaborate on one example that was identified by this approach. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Design of a Multi-Channel Front-End Readout ASIC With Low Noise and Large Dynamic Input Range for APD-Based PET Imaging

    NASA Astrophysics Data System (ADS)

    Fang, X. C.; Hu-Guo, Ch.; Ollivier-Henry, N.; Brasse, D.; Hu, Y.

    2010-06-01

    This paper represents the design of a low-noise, wide band multi-channel readout integrated circuit (IC) used as front end readout electronics of avalanche photo diodes (APD) dedicated to a small animal positron emission tomography (PET) system. The first ten-channel prototype chip (APD-Chip) of the analog parts has been designed and fabricated in a 0.35 μm CMOS process. Every channel of the APD_Chip includes a charge-sensitive preamplifier (CSA), a CR-(RC)2 shaper, and an analog buffer. In a channel, the CSA reads charge signals (10 bits dynamic range) from an APD array having 10 pF of capacitance per pixel. A linearized degenerated differential pair which ensures high linearity in all dynamical range is used as the high feedback resistor for preventing pile up of signals. The designed CSA has the capability of compensating automatically up to 200 nA leakage current from the detector. The CR-(RC)2 shaper filters and shapes the output signal of the CSA. An equivalent input noise charge obtained from test is 275 e -+ 10 e-/pF. In this paper the prototype is presented for both its theoretical analysis and its test results.

  20. Active Stand-off Detection of Gas Leaks Using a Short Range Hard-target Backscatter Differential Optical Absorption System Based on a Quantum Cascade Laser Transmitter

    NASA Astrophysics Data System (ADS)

    Diaz, Adrian; Thomas, Benjamin; Castillo, Paulo; Gross, Barry; Moshary, Fred

    2016-06-01

    Fugitive gas emissions from agricultural or industrial plants and gas pipelines are an important environmental concern as they can contribute to the global increase of greenhouse gas concentration. Moreover, they are also a security and safety concern because of possible risk of fire/explosion or toxicity. This study presents gas concentration measurements using a quantum cascade laser open path system (QCLOPS). The system retrieves the pathaveraged concentration of N2O and CH4 by collecting the backscattered light from a scattering target. The gas concentration measurements have a high temporal resolution (68 ms) and are achieved at sufficient range (up to 40 m, ~ 130 feet) with a detection limit of 2.6 ppm CH4 and 0.4 ppm for N2O. Given these characteristics, this system is promising for mobile/multidirectional remote detection and evaluation of gas leaks. The instrument is monostatic with a tunable QCL emitting at ~ 7.7 μm wavelength range. The backscattered radiation is collected by a Newtonian telescope and focused on an infrared light detector. Puffs of N2O and CH4 are released along the optical path to simulate a gas leak. The measured absorption spectrum is obtained using the thermal intra-pulse frequency chirped DFB QCL and is analyzed to obtain path averaged gas concentrations.

  1. Evaluation of Long-Range Lightning Detection Networks Using TRMM/LIS Observations

    NASA Technical Reports Server (NTRS)

    Rudlosky, Scott D.; Holzworth, Robert H.; Carey, Lawrence D.; Schultz, Chris J.; Bateman, Monte; Cecil, Daniel J.; Cummins, Kenneth L.; Petersen, Walter A.; Blakeslee, Richard J.; Goodman, Steven J.

    2011-01-01

    Recent advances in long-range lightning detection technologies have improved our understanding of thunderstorm evolution in the data sparse oceanic regions. Although the expansion and improvement of long-range lightning datasets have increased their applicability, these applications (e.g., data assimilation, atmospheric chemistry, and aviation weather hazards) require knowledge of the network detection capabilities. Toward this end, the present study evaluates data from the World Wide Lightning Location Network (WWLLN) using observations from the Lightning Imaging Sensor (LIS) aboard the Tropical Rainfall Measurement Mission (TRMM) satellite. The study documents the WWLLN detection efficiency and location accuracy relative to LIS observations, describes the spatial variability in these performance metrics, and documents the characteristics of LIS flashes that are detected by WWLLN. Improved knowledge of the WWLLN detection capabilities will allow researchers, algorithm developers, and operational users to better prepare for the spatial and temporal coverage of the upcoming GOES-R Geostationary Lightning Mapper (GLM).

  2. Laser range profile of cones

    NASA Astrophysics Data System (ADS)

    Zhou, Wenzhen; Gong, Yanjun; Wang, Mingjun; Gong, Lei

    2016-10-01

    technology. Laser one-dimensional range profile can reflect the characteristics of the target shape and surface material. These techniques were motivated by applications of laser radar to target discrimination in ballistic missile defense. The radar equation of pulse laser about cone is given in this paper. This paper demonstrates the analytical model of laser one-dimensional range profile of cone based on the radar equation of the pulse laser. Simulations results of laser one-dimensional range profiles of some cones are given. Laser one-dimensional range profiles of cone, whose surface material with diffuse lambertian reflectance, is given in this paper. Laser one-dimensional range profiles of cone, whose surface mater with diffuse materials whose retroreflectance can be modeled closely with an exponential term that decays with increasing incidence angles, is given in this paper. Laser one-dimensional range profiles of different pulse width of cone is given in this paper. The influences of surface material, pulse width, attitude on the one-dimensional range are analyzed. The laser two-dimensional range profile is two-dimensional scattering imaging of pulse laser of target. The two-dimensional range profile of roughness target can provide range resolved information. An analytical model of two-dimensional laser range profile of cone is proposed. The simulations of two-dimensional laser range profiles of some cones are given. Laser two-dimensional range profiles of cone, whose surface mater with diffuse lambertian reflectance, is given in this paper. Laser two-dimensional range profiles of cone, whose surface mater with diffuse materials whose retroreflectance can be modeled closely with an exponential term that decays with increasing incidence angles, is given in this paper. The influence of pulse width, surface material on laser two-dimensional range profile is analyzed. Laser one-dimensional range profile and laser two-dimensional range profile are called as laser

  3. Genome editing in Kluyveromyces and Ogataea yeasts using a broad-host-range Cas9/gRNA co-expression plasmid.

    PubMed

    Juergens, Hannes; Varela, Javier A; Gorter de Vries, Arthur R; Perli, Thomas; Gast, Veronica J M; Gyurchev, Nikola Y; Rajkumar, Arun S; Mans, Robert; Pronk, Jack T; Morrissey, John P; Daran, Jean-Marc G

    2018-05-01

    While CRISPR-Cas9-mediated genome editing has transformed yeast research, current plasmids and cassettes for Cas9 and guide-RNA expression are species specific. CRISPR tools that function in multiple yeast species could contribute to the intensifying research on non-conventional yeasts. A plasmid carrying a pangenomic origin of replication and two constitutive expression cassettes for Cas9 and ribozyme-flanked gRNAs was constructed. Its functionality was tested by analyzing inactivation of the ADE2 gene in four yeast species. In two Kluyveromyces species, near-perfect targeting (≥96%) and homologous repair (HR) were observed in at least 24% of transformants. In two Ogataea species, Ade- mutants were not observed directly after transformation, but prolonged incubation of transformed cells resulted in targeting efficiencies of 9% to 63% mediated by non-homologous end joining (NHEJ). In an Ogataea parapolymorpha ku80 mutant, deletion of OpADE2 mediated by HR was achieved, albeit at low efficiencies (<1%). Furthermore the expression of a dual polycistronic gRNA array enabled simultaneous interruption of OpADE2 and OpYNR1 demonstrating flexibility of ribozyme-flanked gRNA design for multiplexing. While prevalence of NHEJ prevented HR-mediated editing in Ogataea, such targeted editing was possible in Kluyveromyces. This broad-host-range CRISPR/gRNA system may contribute to exploration of Cas9-mediated genome editing in other Saccharomycotina yeasts.

  4. Laser-ranging scanning system to observe topographical deformations of volcanoes.

    PubMed

    Aoki, T; Takabe, M; Mizutani, K; Itabe, T

    1997-02-20

    We have developed a laser-ranging system to observe the topographical structure of volcanoes. This system can be used to measure the distance to a target by a laser and shows the three-dimensional topographical structure of a volcano with an accuracy of 30 cm. This accuracy is greater than that of a typical laser-ranging system that uses a corner-cube reflector as a target because the reflected light jitters as a result of inclination and unevenness of the target ground surface. However, this laser-ranging system is useful for detecting deformations of topographical features in which placement of a reflector is difficult, such as in volcanic regions.

  5. Acoustic target detection and classification using neural networks

    NASA Technical Reports Server (NTRS)

    Robertson, James A.; Conlon, Mark

    1993-01-01

    A neural network approach to the classification of acoustic emissions of ground vehicles and helicopters is demonstrated. Data collected during the Joint Acoustic Propagation Experiment conducted in July of l991 at White Sands Missile Range, New Mexico was used to train a classifier to distinguish between the spectrums of a UH-1, M60, M1 and M114. An output node was also included that would recognize background (i.e. no target) data. Analysis revealed specific hidden nodes responding to the features input into the classifier. Initial results using the neural network were encouraging with high correct identification rates accompanied by high levels of confidence.

  6. Impact buckling of thin bars in the elastic range hinged at both ends

    NASA Technical Reports Server (NTRS)

    Koning, Carel; Taub, Josef

    1934-01-01

    Following the development of the well-known differential equations of the problem and their resolution for failure in tension, the bending (transverse) oscillations of an originally not quite straight bar hinged at both ends and subjected to a constant longitudinal force (shock load) are analyzed. To this end the course of the bar form is expanded in a sinusoidal series, after which the investigation is carried through separately for the fundamental oscillation and the (n-1)the higher oscillations. The analysis of the fundamental oscillation distinguishes three cases: shock load lower, equal to, or higher than the Eulerian load. The investigation leads to functions which are proportional to the maximum stresses in time and space due to the shock stresses in buckling.

  7. Use of the smartphone for end vertebra selection in scoliosis.

    PubMed

    Pepe, Murad; Kocadal, Onur; Iyigun, Abdullah; Gunes, Zafer; Aksahin, Ertugrul; Aktekin, Cem Nuri

    2017-03-01

    The aim of our study was to develop a smartphone-aided end vertebra selection method and to investigate its effectiveness in Cobb angle measurement. Twenty-nine adolescent idiopathic scoliosis patients' pre-operative posteroanterior scoliosis radiographs were used for end vertebra selection and Cobb angle measurement by standard method and smartphone-aided method. Measurements were performed by 7 examiners. The intraclass correlation coefficient was used to analyze selection and measurement reliability. Summary statistics of variance calculations were used to provide 95% prediction limits for the error in Cobb angle measurements. A paired 2-tailed t test was used to analyze end vertebra selection differences. Mean absolute Cobb angle difference was 3.6° for the manual method and 1.9° for the smartphone-aided method. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for Cobb angle measurement. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for end vertebra selection. But reliability values of manual set were lower than smartphone. Two observers selected significantly different end vertebra in their repeated selections for manual method. Smartphone-aided method for end vertebra selection and Cobb angle measurement showed excellent reliability. We can expect a reduction in measurement error rates with the widespread use of this method in clinical practice. Level III, Diagnostic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  8. Development of a New DNA Vaccine for Alzheimer Disease Targeting a Wide Range of Aβ Species and Amyloidogenic Peptides

    PubMed Central

    Matsumoto, Yoh; Niimi, Naoko; Kohyama, Kuniko

    2013-01-01

    It has recently been determined that not only Aβ oligomers, but also other Aβ species and amyloidogenic peptides are neurotoxic in Alzheimer disease (AD) and play a pivotal role in AD pathogenesis. In the present study, we attempted to develop new DNA vaccines targeting a wide range of Aβ species. For this purpose, we first performed in vitro assays with newly developed vaccines to evaluate Aβ production and Aβ secretion abilities and then chose an IgL-Aβx4-Fc-IL-4 vaccine (designated YM3711) for further studies. YM3711 was vaccinated to mice, rabbits and monkeys to evaluate anti-Aβ species antibody-producing ability and Aβ reduction effects. It was found that YM3711 vaccination induced significantly higher levels of antibodies not only to Aβ1-42 but also to AD-related molecules including AβpE3-42, Aβ oligomers and Aβ fibrils. Importantly, YM3711 significantly reduced these Aβ species in the brain of model mice. Binding and competition assays using translated YM3711 protein products clearly demonstrated that a large part of antibodies induced by YM3711 vaccination are directed at conformational epitopes of the Aβ complex and oligomers. Taken together, we demonstrate that YM3711 is a powerful DNA vaccine targeting a wide range of AD-related molecules and is worth examining in preclinical and clinical trials. PMID:24086465

  9. Comparison between analog and digital neural network implementations for range-finding applications.

    PubMed

    Gatet, Laurent; Tap-Béteille, Hélène; Bony, Francis

    2009-03-01

    A neural network (NN) was developed in order to increase the distance range of a phase-shift laser range finder and to achieve surface recognition, by using two photoelectrical signals issued from the measurement system. The NN architecture consists of a multilayer perceptron (MLP) with two inputs, three neurons in the hidden layer, and one output. Depending on the application, the NN output has to resolve the ambiguity due to phase-shift measurement by linearizing the inverse of the square law, or to indicate an output voltage corresponding to the tested surface. This embedded system dedicated to optoelectronic measurements was successfully tested with an analog NN, implemented in 0.35- microm complimentary metal-oxide-semiconductor (CMOS) technology, resulting in a threefold increase in the distance range with respect to the one limited by the phase-shift measurement, and by discriminating four types of surfaces (a plastic surface, glossy paper, a painted wall, and a porous surface), at a remote distance between the range finder and the target varying from 0.5 m up to 1.25 m and with a laser beam angle varying between -pi/6 and pi/6 with respect to the target. In this type of application, NN analog implementation provides many advantages, notably use of a small silicon area, low power consumption and no analog-to-digital conversions (ADCs). Nevertheless, digital implementation allows ease of conception and reconfigurability and an embedded weight and bias update. This paper presents the complete measurement system and a comparison between both types of implementation, by developing the advantages and drawbacks relative to each method. An optimized mixed architecture, using both techniques, is then proposed and discussed at the end of the paper.

  10. Environmental genotoxicity evaluation using cytogenetic end points in wild rodents.

    PubMed Central

    de Souza Bueno, A M; de Bragança Pereira, C A; Rabello-Gay, M N

    2000-01-01

    We analyzed cytogenetic end points in three populations of two species of wild rodents--Akodon montensis and Oryzomys nigripes--living in an industrial, an agricultural, and a preservation area at the Itajaí Valley, state of Santa Catarina, Brazil. Our purpose was to evaluate the performance of the following end points in the establishment of a genotoxic profile of each area: the polychromatic/normochromatic cell ratio; the mitotic index; the frequency of micronucleated cells both in the bone marrow and peripheral blood; and the frequency of cells with chromosome aberrations in the bone marrow. Preparations were obtained using conventional cytogenetic techniques. The results showed a) the role of the end points used as biomarkers in the early detection of genotoxic agents and in the identification of species and populations at higher risk; b) the difference in sensitivity of the species selected as bioindicators in relation to the cytogenetic end points analyzed; c) the need to use at least two sympatric species to detect the presence of genotoxins in each locality; and d) the need to use several end points when trying to establish a genotoxic profile of an area. PMID:11133397

  11. Intracellular Protein Delivery System Using a Target-Specific Repebody and Translocation Domain of Bacterial Exotoxin.

    PubMed

    Kim, Hee-Yeon; Kang, Jung Ae; Ryou, Jeong-Hyun; Lee, Gyeong Hee; Choi, Dae Seong; Lee, Dong Eun; Kim, Hak-Sung

    2017-11-17

    With the high efficacy of protein-based therapeutics and plenty of intracellular drug targets, cytosolic protein delivery in a cell-specific manner has attracted considerable attention in the field of precision medicine. Herein, we present an intracellular protein delivery system based on a target-specific repebody and the translocation domain of Pseudomonas aeruginosa exotoxin A. The delivery platform was constructed by genetically fusing an EGFR-specific repebody as a targeting moiety to the translocation domain, while a protein cargo was fused to the C-terminal end of the delivery platform. The delivery platform was revealed to efficiently translocate a protein cargo to the cytosol in a target-specific manner. We demonstrate the utility and potential of the delivery platform by showing a remarkable tumor regression with negligible toxicity in a xenograft mice model when gelonin was used as the cytotoxic protein cargo. The present platform can find wide applications to the cell-selective cytosolic delivery of diverse proteins in many areas.

  12. MRI simulation: end-to-end testing for prostate radiation therapy using geometric pelvic MRI phantoms

    NASA Astrophysics Data System (ADS)

    Sun, Jidi; Dowling, Jason; Pichler, Peter; Menk, Fred; Rivest-Henault, David; Lambert, Jonathan; Parker, Joel; Arm, Jameen; Best, Leah; Martin, Jarad; Denham, James W.; Greer, Peter B.

    2015-04-01

    To clinically implement MRI simulation or MRI-alone treatment planning requires comprehensive end-to-end testing to ensure an accurate process. The purpose of this study was to design and build a geometric phantom simulating a human male pelvis that is suitable for both CT and MRI scanning and use it to test geometric and dosimetric aspects of MRI simulation including treatment planning and digitally reconstructed radiograph (DRR) generation. A liquid filled pelvic shaped phantom with simulated pelvic organs was scanned in a 3T MRI simulator with dedicated radiotherapy couch-top, laser bridge and pelvic coil mounts. A second phantom with the same external shape but with an internal distortion grid was used to quantify the distortion of the MR image. Both phantoms were also CT scanned as the gold-standard for both geometry and dosimetry. Deformable image registration was used to quantify the MR distortion. Dose comparison was made using a seven-field IMRT plan developed on the CT scan with the fluences copied to the MR image and recalculated using bulk electron densities. Without correction the maximum distortion of the MR compared with the CT scan was 7.5 mm across the pelvis, while this was reduced to 2.6 and 1.7 mm by the vendor’s 2D and 3D correction algorithms, respectively. Within the locations of the internal organs of interest, the distortion was <1.5 and <1 mm with 2D and 3D correction algorithms, respectively. The dose at the prostate isocentre calculated on CT and MRI images differed by 0.01% (1.1 cGy). Positioning shifts were within 1 mm when setup was performed using MRI generated DRRs compared to setup using CT DRRs. The MRI pelvic phantom allows end-to-end testing of the MRI simulation workflow with comparison to the gold-standard CT based process. MRI simulation was found to be geometrically accurate with organ dimensions, dose distributions and DRR based setup within acceptable limits compared to CT.

  13. Improving and validating children's nurses communication skills with standardized patients in end of life care.

    PubMed

    Kenny, Gerard; Cargil, Jamie; Hamilton, Catherine; Sales, Rachel

    2016-06-01

    Children's nurse education is experiencing increases in recruitment targets at the same time that clinical placements are decreasing. With regard to end-of-life care, it is has become a challenge to ensure that all students come into contact with a satisfactory range of experience as part of the requirement for competency at the point of registration. The aim of our study was to find out if students at the end of their course were able to use communication skills acquired in their three years of training and adapt and transfer them to a specific palliative care context even if they had never worked in that area of care. Focus groups were conducted after the simulations which explored the students' experiences of being involved in the scenarios. Four themes emerged that students identified either inhibited or enabled their communication skills, which included anxiety and fear, the need for professional props, the experience of it being real and feeling empowered. © The Author(s) 2014.

  14. Spatial Cognition and Range Use in Free-Range Laying Hens.

    PubMed

    Campbell, Dana L M; Talk, Andrew C; Loh, Ziyang A; Dyall, Tim R; Lee, Caroline

    2018-02-08

    Radio-frequency identification tracking shows individual free-range laying hens vary in range use, with some never going outdoors. The range is typically more environmentally complex, requiring navigation to return to the indoor resources. Outdoor-preferring hens may have improved spatial abilities compared to indoor-preferring hens. Experiment 1 tested 32 adult ISA Brown hens in a T-maze learning task that showed exclusively-indoor birds were slowest to reach the learning success criterion ( p < 0.05). Experiment 2 tested 117 pullets from enriched or non-enriched early rearing treatments (1 pen replicate per treatment) in the same maze at 15-16 or 17-18 weeks. Enriched birds reached learning success criterion faster at 15-16 weeks ( p < 0.05) but not at 17-18 weeks ( p > 0.05), the age that coincided with the onset of lay. Enriched birds that were faster to learn the maze task showed more range visits in the first 4 weeks of range access. Enriched and non-enriched birds showed no differences in telencephalon or hippocampal volume ( p > 0.05). Fear may reduce spatial abilities but further testing with more pen replicates per early rearing treatments would improve our understanding of the relationship between spatial cognitive abilities and range use.

  15. Gain enhancement for wideband end-fire antenna design with artificial material.

    PubMed

    Wei, Min; Sun, Yuanhua; Wu, Xi; Wen, Wu

    2016-01-01

    Gain enhancement wideband end-fire antenna is proposed in this paper. The proposed antenna can achieve gain enhancement by loading novel artificial materials structures (Split-ring Resonators) in the end-fire direction while broad bandwidth is realized by using elliptic dipole elements and a microstrip to coplanar balun. The measurements show that the proposed antenna have around 5-8 dB gain in the working band (5-11 GHz), which is around 2 dB more than the unloaded one. This antenna can be used in target recognition systems for its advantages of end-fire radiation broad bandwidth and high gain.

  16. UGS video target detection and discrimination

    NASA Astrophysics Data System (ADS)

    Roberts, G. Marlon; Fitzgerald, James; McCormack, Michael; Steadman, Robert; Vitale, Joseph D.

    2007-04-01

    This project focuses on developing electro-optic algorithms which rank images by their likelihood of containing vehicles and people. These algorithms have been applied to images obtained from Textron's Terrain Commander 2 (TC2) Unattended Ground Sensor system. The TC2 is a multi-sensor surveillance system used in military applications. It combines infrared, acoustic, seismic, magnetic, and electro-optic sensors to detect nearby targets. When targets are detected by the seismic and acoustic sensors, the system is triggered and images are taken in the visible and infrared spectrum. The original Terrain Commander system occasionally captured and transmitted an excessive number of images, sometimes triggered by undesirable targets such as swaying trees. This wasted communications bandwidth, increased power consumption, and resulted in a large amount of end-user time being spent evaluating unimportant images. The algorithms discussed here help alleviate these problems. These algorithms are currently optimized for infra-red images, which give the best visibility in a wide range of environments, but could be adapted to visible imagery as well. It is important that the algorithms be robust, with minimal dependency on user input. They should be effective when tracking varying numbers of targets of different sizes and orientations, despite the low resolutions of the images used. Most importantly, the algorithms must be appropriate for implementation on a low-power processor in real time. This would enable us to maintain frame rates of 2 Hz for effective surveillance operations. Throughout our project we have implemented several algorithms, and used an appropriate methodology to quantitatively compare their performance. They are discussed in this paper.

  17. Close-Range Tracking of Underwater Vehicles Using Light Beacons

    PubMed Central

    Bosch, Josep; Gracias, Nuno; Ridao, Pere; Istenič, Klemen; Ribas, David

    2016-01-01

    This paper presents a new tracking system for autonomous underwater vehicles (AUVs) navigating in a close formation, based on computer vision and the use of active light markers. While acoustic localization can be very effective from medium to long distances, it is not so advantageous in short distances when the safety of the vehicles requires higher accuracy and update rates. The proposed system allows the estimation of the pose of a target vehicle at short ranges, with high accuracy and execution speed. To extend the field of view, an omnidirectional camera is used. This camera provides a full coverage of the lower hemisphere and enables the concurrent tracking of multiple vehicles in different positions. The system was evaluated in real sea conditions by tracking vehicles in mapping missions, where it demonstrated robust operation during extended periods of time. PMID:27023547

  18. Close-Range Tracking of Underwater Vehicles Using Light Beacons.

    PubMed

    Bosch, Josep; Gracias, Nuno; Ridao, Pere; Istenič, Klemen; Ribas, David

    2016-03-25

    This paper presents a new tracking system for autonomous underwater vehicles (AUVs) navigating in a close formation, based on computer vision and the use of active light markers. While acoustic localization can be very effective from medium to long distances, it is not so advantageous in short distances when the safety of the vehicles requires higher accuracy and update rates. The proposed system allows the estimation of the pose of a target vehicle at short ranges, with high accuracy and execution speed. To extend the field of view, an omnidirectional camera is used. This camera provides a full coverage of the lower hemisphere and enables the concurrent tracking of multiple vehicles in different positions. The system was evaluated in real sea conditions by tracking vehicles in mapping missions, where it demonstrated robust operation during extended periods of time.

  19. Supercharged end-to-side anterior interosseous to ulnar motor nerve transfer for intrinsic musculature reinnervation.

    PubMed

    Barbour, John; Yee, Andrew; Kahn, Lorna C; Mackinnon, Susan E

    2012-10-01

    Functional motor recovery after peripheral nerve injury is predominantly determined by the time to motor end plate reinnervation and the absolute number of regenerated motor axons that reach target. Experimental models have shown that axonal regeneration occurs across a supercharged end-to-side (SETS) nerve coaptation. In patients with a recovering proximal ulnar nerve injury, a SETS nerve transfer conceptually is useful to protect and preserve distal motor end plates until the native axons fully regenerate. In addition, for nerve injuries in which incomplete regeneration is anticipated, a SETS nerve transfer may be useful to augment the regenerating nerve with additional axons and to more quickly reinnervate target muscle. We describe our technique for a SETS nerve transfer of the terminal anterior interosseous nerve (AIN) to the pronator quadratus muscle (PQ) end-to-side to the deep motor fascicle of the ulnar nerve in the distal forearm. In addition, we describe our postoperative therapy regimen for these transfers and an evaluation tool for monitoring progressive muscle reinnervation. Although the AIN-to-ulnar motor group SETS nerve transfer was specifically designed for ulnar nerve injuries, we believe that the SETS procedure might have broad clinical utility for second- and third-degree axonotmetic nerve injuries, to augment partial recovery and/or "babysit" motor end plates until the native parent axons regenerate to target. We would consider all donor nerves currently utilized in end-to-end nerve transfers for neurotmetic injuries as candidates for this SETS technique. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. Performance Analysis of Ranging Techniques for the KPLO Mission

    NASA Astrophysics Data System (ADS)

    Park, Sungjoon; Moon, Sangman

    2018-03-01

    In this study, the performance of ranging techniques for the Korea Pathfinder Lunar Orbiter (KPLO) space communication system is investigated. KPLO is the first lunar mission of Korea, and pseudo-noise (PN) ranging will be used to support the mission along with sequential ranging. We compared the performance of both ranging techniques using the criteria of accuracy, acquisition probability, and measurement time. First, we investigated the end-to-end accuracy error of a ranging technique incorporating all sources of errors such as from ground stations and the spacecraft communication system. This study demonstrates that increasing the clock frequency of the ranging system is not required when the dominant factor of accuracy error is independent of the thermal noise of the ranging technique being used in the system. Based on the understanding of ranging accuracy, the measurement time of PN and sequential ranging are further investigated and compared, while both techniques satisfied the accuracy and acquisition requirements. We demonstrated that PN ranging performed better than sequential ranging in the signal-to-noise ratio (SNR) regime where KPLO will be operating, and we found that the T2B (weighted-voting balanced Tausworthe, voting v = 2) code is the best choice among the PN codes available for the KPLO mission.

  1. Rapid Target Detection in High Resolution Remote Sensing Images Using Yolo Model

    NASA Astrophysics Data System (ADS)

    Wu, Z.; Chen, X.; Gao, Y.; Li, Y.

    2018-04-01

    Object detection in high resolution remote sensing images is a fundamental and challenging problem in the field of remote sensing imagery analysis for civil and military application due to the complex neighboring environments, which can cause the recognition algorithms to mistake irrelevant ground objects for target objects. Deep Convolution Neural Network(DCNN) is the hotspot in object detection for its powerful ability of feature extraction and has achieved state-of-the-art results in Computer Vision. Common pipeline of object detection based on DCNN consists of region proposal, CNN feature extraction, region classification and post processing. YOLO model frames object detection as a regression problem, using a single CNN predicts bounding boxes and class probabilities in an end-to-end way and make the predict faster. In this paper, a YOLO based model is used for object detection in high resolution sensing images. The experiments on NWPU VHR-10 dataset and our airport/airplane dataset gain from GoogleEarth show that, compare with the common pipeline, the proposed model speeds up the detection process and have good accuracy.

  2. Target recognitions in multiple-camera closed-circuit television using color constancy

    NASA Astrophysics Data System (ADS)

    Soori, Umair; Yuen, Peter; Han, Ji Wen; Ibrahim, Izzati; Chen, Wentao; Hong, Kan; Merfort, Christian; James, David; Richardson, Mark

    2013-04-01

    People tracking in crowded scenes from closed-circuit television (CCTV) footage has been a popular and challenging task in computer vision. Due to the limited spatial resolution in the CCTV footage, the color of people's dress may offer an alternative feature for their recognition and tracking. However, there are many factors, such as variable illumination conditions, viewing angles, and camera calibration, that may induce illusive modification of intrinsic color signatures of the target. Our objective is to recognize and track targets in multiple camera views using color as the detection feature, and to understand if a color constancy (CC) approach may help to reduce these color illusions due to illumination and camera artifacts and thereby improve target recognition performance. We have tested a number of CC algorithms using various color descriptors to assess the efficiency of target recognition from a real multicamera Imagery Library for Intelligent Detection Systems (i-LIDS) data set. Various classifiers have been used for target detection, and the figure of merit to assess the efficiency of target recognition is achieved through the area under the receiver operating characteristics (AUROC). We have proposed two modifications of luminance-based CC algorithms: one with a color transfer mechanism and the other using a pixel-wise sigmoid function for an adaptive dynamic range compression, a method termed enhanced luminance reflectance CC (ELRCC). We found that both algorithms improve the efficiency of target recognitions substantially better than that of the raw data without CC treatment, and in some cases the ELRCC improves target tracking by over 100% within the AUROC assessment metric. The performance of the ELRCC has been assessed over 10 selected targets from three different camera views of the i-LIDS footage, and the averaged target recognition efficiency over all these targets is found to be improved by about 54% in AUROC after the data are processed by

  3. Improved linearity using harmonic error rejection in a full-field range imaging system

    NASA Astrophysics Data System (ADS)

    Payne, Andrew D.; Dorrington, Adrian A.; Cree, Michael J.; Carnegie, Dale A.

    2008-02-01

    Full field range imaging cameras are used to simultaneously measure the distance for every pixel in a given scene using an intensity modulated illumination source and a gain modulated receiver array. The light is reflected from an object in the scene, and the modulation envelope experiences a phase shift proportional to the target distance. Ideally the waveforms are sinusoidal, allowing the phase, and hence object range, to be determined from four measurements using an arctangent function. In practice these waveforms are often not perfectly sinusoidal, and in some cases square waveforms are instead used to simplify the electronic drive requirements. The waveforms therefore commonly contain odd harmonics which contribute a nonlinear error to the phase determination, and therefore an error in the range measurement. We have developed a unique sampling method to cancel the effect of these harmonics, with the results showing an order of magnitude improvement in the measurement linearity without the need for calibration or lookup tables, while the acquisition time remains unchanged. The technique can be applied to existing range imaging systems without having to change or modify the complex illumination or sensor systems, instead only requiring a change to the signal generation and timing electronics.

  4. Emissions from Residential Combustion considering End-Uses and Spatial Constraints

    NASA Astrophysics Data System (ADS)

    Bond, T. C.; Lam, N. L.; Winijkul, E.

    2015-12-01

    Cooking, heating, and other activities in the residential sector are major sources of indoor and outdoor air pollution, especially when solid fuels provide energy. Because of these deleterious effects, multinational strategies to alter technology and reduce emissions have been proposed, but to date, they have ignored many constraints on feasibility. We describe a framework to apportion national energy consumption among land types and household end-uses, to calculate emissions, and to evaluate mitigation strategies. We provide year-2010 emissions of particulate matter, black carbon, organic carbon, nitrogen oxides, methane, non-methane hydrocarbons, carbon monoxide, and carbon dioxide. The study area includes regions where solid biomass fuel provides more than 50% of total residential energy: Latin America, Africa, and Asia. Using nightlight data and population density, we classify land types as urban, electrified rural with and without forest access, and non-electrified rural with and without forest access. We apportion national-level residential fuel consumption among land types and end-uses, and assign technologies to each combination. About 13% of energy is consumed in urban areas, and 45% in non-urban land near forests. About half the energy is consumed in land without access to electricity. Cooking accounts for 54% of consumption, heating 9%, and lighting only 2%, with unidentified uses making up the remainder. We examine possible policies, considering realistic factors that constrain mitigation. Scenarios explored are: (1) cleanest current stove, where plausible existing technology is deployed; (2) stove standards, where stoves are designed to meet performance standards; and (3) clean fuels, where users adopt the cleanest plausible fuels; we assume that people living in forest access areas continue to use wood. For cleaner stoves, emission reductions range from 25-82%, depending on the pollutant. The clean-fuels scenario reduces emissions by 18-25%.

  5. 77 FR 51459 - Suspension of End-Use Certificate Program Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-24

    ... indefinitely the Farm Service Agency (FSA) regulation requiring end-use certificates and tracking of wheat... Canadian produced wheat are no longer required to provide FSA end-use certificates or consumption and resale reports on wheat produced in Canada. DATES: Effective August 31, 2012. FOR FURTHER INFORMATION...

  6. SNP discovery in candidate adaptive genes using exon capture in a free-ranging alpine ungulate

    USGS Publications Warehouse

    Roffler, Gretchen H.; Amish, Stephen J.; Smith, Seth; Cosart, Ted F.; Kardos, Marty; Schwartz, Michael K.; Luikart, Gordon

    2016-01-01

    Identification of genes underlying genomic signatures of natural selection is key to understanding adaptation to local conditions. We used targeted resequencing to identify SNP markers in 5321 candidate adaptive genes associated with known immunological, metabolic and growth functions in ovids and other ungulates. We selectively targeted 8161 exons in protein-coding and nearby 5′ and 3′ untranslated regions of chosen candidate genes. Targeted sequences were taken from bighorn sheep (Ovis canadensis) exon capture data and directly from the domestic sheep genome (Ovis aries v. 3; oviAri3). The bighorn sheep sequences used in the Dall's sheep (Ovis dalli dalli) exon capture aligned to 2350 genes on the oviAri3 genome with an average of 2 exons each. We developed a microfluidic qPCR-based SNP chip to genotype 476 Dall's sheep from locations across their range and test for patterns of selection. Using multiple corroborating approaches (lositan and bayescan), we detected 28 SNP loci potentially under selection. We additionally identified candidate loci significantly associated with latitude, longitude, precipitation and temperature, suggesting local environmental adaptation. The three methods demonstrated consistent support for natural selection on nine genes with immune and disease-regulating functions (e.g. Ovar-DRA, APC, BATF2, MAGEB18), cell regulation signalling pathways (e.g. KRIT1, PI3K, ORRC3), and respiratory health (CYSLTR1). Characterizing adaptive allele distributions from novel genetic techniques will facilitate investigation of the influence of environmental variation on local adaptation of a northern alpine ungulate throughout its range. This research demonstrated the utility of exon capture for gene-targeted SNP discovery and subsequent SNP chip genotyping using low-quality samples in a nonmodel species.

  7. Massively Parallel Sequencing of Patients with Intellectual Disability, Congenital Anomalies and/or Autism Spectrum Disorders with a Targeted Gene Panel

    PubMed Central

    Brett, Maggie; McPherson, John; Zang, Zhi Jiang; Lai, Angeline; Tan, Ee-Shien; Ng, Ivy; Ong, Lai-Choo; Cham, Breana; Tan, Patrick; Rozen, Steve; Tan, Ene-Choo

    2014-01-01

    Developmental delay and/or intellectual disability (DD/ID) affects 1–3% of all children. At least half of these are thought to have a genetic etiology. Recent studies have shown that massively parallel sequencing (MPS) using a targeted gene panel is particularly suited for diagnostic testing for genetically heterogeneous conditions. We report on our experiences with using massively parallel sequencing of a targeted gene panel of 355 genes for investigating the genetic etiology of eight patients with a wide range of phenotypes including DD/ID, congenital anomalies and/or autism spectrum disorder. Targeted sequence enrichment was performed using the Agilent SureSelect Target Enrichment Kit and sequenced on the Illumina HiSeq2000 using paired-end reads. For all eight patients, 81–84% of the targeted regions achieved read depths of at least 20×, with average read depths overlapping targets ranging from 322× to 798×. Causative variants were successfully identified in two of the eight patients: a nonsense mutation in the ATRX gene and a canonical splice site mutation in the L1CAM gene. In a third patient, a canonical splice site variant in the USP9X gene could likely explain all or some of her clinical phenotypes. These results confirm the value of targeted MPS for investigating DD/ID in children for diagnostic purposes. However, targeted gene MPS was less likely to provide a genetic diagnosis for children whose phenotype includes autism. PMID:24690944

  8. Open Targets: a platform for therapeutic target identification and validation

    PubMed Central

    Koscielny, Gautier; An, Peter; Carvalho-Silva, Denise; Cham, Jennifer A.; Fumis, Luca; Gasparyan, Rippa; Hasan, Samiul; Karamanis, Nikiforos; Maguire, Michael; Papa, Eliseo; Pierleoni, Andrea; Pignatelli, Miguel; Platt, Theo; Rowland, Francis; Wankar, Priyanka; Bento, A. Patrícia; Burdett, Tony; Fabregat, Antonio; Forbes, Simon; Gaulton, Anna; Gonzalez, Cristina Yenyxe; Hermjakob, Henning; Hersey, Anne; Jupe, Steven; Kafkas, Şenay; Keays, Maria; Leroy, Catherine; Lopez, Francisco-Javier; Magarinos, Maria Paula; Malone, James; McEntyre, Johanna; Munoz-Pomer Fuentes, Alfonso; O'Donovan, Claire; Papatheodorou, Irene; Parkinson, Helen; Palka, Barbara; Paschall, Justin; Petryszak, Robert; Pratanwanich, Naruemon; Sarntivijal, Sirarat; Saunders, Gary; Sidiropoulos, Konstantinos; Smith, Thomas; Sondka, Zbyslaw; Stegle, Oliver; Tang, Y. Amy; Turner, Edward; Vaughan, Brendan; Vrousgou, Olga; Watkins, Xavier; Martin, Maria-Jesus; Sanseau, Philippe; Vamathevan, Jessica; Birney, Ewan; Barrett, Jeffrey; Dunham, Ian

    2017-01-01

    We have designed and developed a data integration and visualization platform that provides evidence about the association of known and potential drug targets with diseases. The platform is designed to support identification and prioritization of biological targets for follow-up. Each drug target is linked to a disease using integrated genome-wide data from a broad range of data sources. The platform provides either a target-centric workflow to identify diseases that may be associated with a specific target, or a disease-centric workflow to identify targets that may be associated with a specific disease. Users can easily transition between these target- and disease-centric workflows. The Open Targets Validation Platform is accessible at https://www.targetvalidation.org. PMID:27899665

  9. System considerations for detection and tracking of small targets using passive sensors

    NASA Astrophysics Data System (ADS)

    DeBell, David A.

    1991-08-01

    Passive sensors provide only a few discriminants to assist in threat assessment of small targets. Tracking of the small targets provides additional discriminants. This paper discusses the system considerations for tracking small targets using passive sensors, in particular EO sensors. Tracking helps establish good versus bad detections. Discussed are the requirements to be placed on the sensor system's accuracy, with respect to knowledge of the sightline direction. The detection of weak targets sets a requirement for two levels of tracking in order to reduce processor throughput. A system characteristic is the need to track all detections. For low thresholds, this can mean a heavy track burden. Therefore, thresholds must be adaptive in order not to saturate the processors. Second-level tracks must develop a range estimate in order to assess threat. Sensor platform maneuvers are required if the targets are moving. The need for accurate pointing, good stability, and a good update rate will be shown quantitatively, relating to track accuracy and track association.

  10. Shallow End Response from ATEM

    NASA Astrophysics Data System (ADS)

    Vetrov, A.

    2014-12-01

    Different geological, hydrological, environmental and engineering targets are located shallow underground. The information collected with ATEM systems might be very useful for their study; although there are many deeper targets that the ATEM systems are traditionally used for. The idea to raise magnetic moment output and get deeper penetration response was one of the goals of ATEM systems development during the last decade. The shallow geology response was a trade for such systems, which sometimes were almost blind in the first hundred meter under surface. The possibility to achieve shallow end response from ATEM systems has become significant subject in last years. Several airborne TDEM systems got second higher frequency and lower magnetic moment signal to pick up shallow response together with deep one. Having a potential advantage such implementation raises complication and cost of the system. There's no need to receive 500 meter deep response when exploring shallow geology. P-THEM system having a compact size transmitter and relatively light weight is working on one base frequency at a time, but this frequency can be preset before a flight considering survey goals. A study of shallow geology response of the P-THEM system working on different base frequency has been conducted in 2014 in Ontario. The Alliston test area located in Southern Ontario has been flown with the P-THEM system working on base frequencies 30Hz and 90Hz. Results of the observations will be discussed in the presentation. The shallow end data can be used for mineral exploration applications and also for hydrological and environmental studies.

  11. The CO2 stimulus for cerebrovascular reactivity: Fixing inspired concentrations vs. targeting end-tidal partial pressures.

    PubMed

    Fisher, Joseph A

    2016-06-01

    Cerebrovascular reactivity (CVR) studies have elucidated the physiology and pathophysiology of cerebral blood flow regulation. A non-invasive, high spatial resolution approach uses carbon dioxide (CO2) as the vasoactive stimulus and magnetic resonance techniques to estimate the cerebral blood flow response. CVR is assessed as the ratio response change to stimulus change. Precise control of the stimulus is sought to minimize CVR variability between tests, and show functional differences. Computerized methods targeting end-tidal CO2 partial pressures are precise, but expensive. Simpler, improvised methods that fix the inspired CO2 concentrations have been recommended as less expensive, and so more widely accessible. However, these methods have drawbacks that have not been previously presented by those that advocate their use, or those that employ them in their studies. As one of the developers of a computerized method, I provide my perspective on the trade-offs between these two methods. The main concern is that declaring the precision of fixed inspired concentration of CO2 is misleading: it does not, as implied, translate to precise control of the actual vasoactive stimulus - the arterial partial pressure of CO2 The inherent test-to-test, and therefore subject-to-subject variability, precludes clinical application of findings. Moreover, improvised methods imply widespread duplication of development, assembly time and costs, yet lack uniformity and quality control. A tabular comparison between approaches is provided. © The Author(s) 2016.

  12. Geology of the north end of the Ruby Range, southwestern Montana

    USGS Publications Warehouse

    Tysdal, Russell G.

    1970-01-01

    This study consists of two parts: stratigraphy and sedimentation, and structure of rocks in the northern one-third of the Ruby Range of southwestern Montana. Detailed studies of Cambrian marine dolomite rocks in the Red Lion Formation and in the upper part of the Pilgrim Limestone resulted in their division into distinct rock units, termed lithofacies. These lithofacies contain features suggestive of subtidal, intertidal, and supratidal environments similar to those presently forming in the Persian Gulf. Stromatolltic structures occurring in the uppermost part of the Red Lion Formation are similar to those presently forming in Shark Bay, Australia. The Ruby Range within the map area is broken into a series of northwest-plunging basement (Precambrian metamorphic rock) blocks, differentially uplifted during the Cretaceous-Tertiary orogenic period. These blocks are bordered by upthrust faults, which are nearly vertical in their lower segments and are .low-angle in their uppermost parts. Asymmetrical folds in Paleozoic sedimentary rocks formed in response to the differential uplift of the blocks; thus they too plunge to the northwest. Displaced masses of rock border the range on the three sides within the map area and are interpreted as gravity-slide features resulting from uplift of the range. Normal faulting began blocking out the present range margins by Oligocene time.

  13. Development of target ion source systems for radioactive beams at GANIL

    NASA Astrophysics Data System (ADS)

    Bajeat, O.; Delahaye, P.; Couratin, C.; Dubois, M.; Franberg-Delahaye, H.; Henares, J. L.; Huguet, Y.; Jardin, P.; Lecesne, N.; Lecomte, P.; Leroy, R.; Maunoury, L.; Osmond, B.; Sjodin, M.

    2013-12-01

    The GANIL facility (Caen, France) is dedicated to the acceleration of heavy ion beams including radioactive beams produced by the Isotope Separation On-Line (ISOL) method at the SPIRAL1 facility. To extend the range of radioactive ion beams available at GANIL, using the ISOL method two projects are underway: SPIRAL1 upgrade and the construction of SPIRAL2. For SPIRAL1, a new target ion source system (TISS) using the VADIS FEBIAD ion source coupled to the SPIRAL1 carbon target will be tested on-line by the end of 2013 and installed in the cave of SPIRAL1 for operation in 2015. The SPIRAL2 project is under construction and is being design for using different production methods as fission, fusion or spallation reactions to cover a large area of the chart of nuclei. It will produce among others neutron rich beams obtained by the fission of uranium induced by fast neutrons. The production target made from uranium carbide and heated at 2000 °C will be associated with several types of ion sources. Developments currently in progress at GANIL for each of these projects are presented.

  14. Enhancing bioactive peptide release and identification using targeted enzymatic hydrolysis of milk proteins.

    PubMed

    Nongonierma, Alice B; FitzGerald, Richard J

    2018-06-01

    Milk proteins have been extensively studied for their ability to yield a range of bioactive peptides following enzymatic hydrolysis/digestion. However, many hurdles still exist regarding the widespread utilization of milk protein-derived bioactive peptides as health enhancing agents for humans. These mostly arise from the fact that most milk protein-derived bioactive peptides are not highly potent. In addition, they may be degraded during gastrointestinal digestion and/or have a low intestinal permeability. The targeted release of bioactive peptides during the enzymatic hydrolysis of milk proteins may allow the generation of particularly potent bioactive hydrolysates and peptides. Therefore, the development of milk protein hydrolysates capable of improving human health requires, in the first instance, optimized targeted release of specific bioactive peptides. The targeted hydrolysis of milk proteins has been aided by a range of in silico tools. These include peptide cutters and predictive modeling linking bioactivity to peptide structure [i.e., molecular docking, quantitative structure activity relationship (QSAR)], or hydrolysis parameters [design of experiments (DOE)]. Different targeted enzymatic release strategies employed during the generation of milk protein hydrolysates are reviewed herein and their limitations are outlined. In addition, specific examples are provided to demonstrate how in silico tools may help in the identification and discovery of potent milk protein-derived peptides. It is anticipated that the development of novel strategies employing a range of in silico tools may help in the generation of milk protein hydrolysates containing potent and bioavailable peptides, which in turn may be used to validate their health promoting effects in humans. Graphical abstract The targeted enzymatic hydrolysis of milk proteins may allow the generation of highly potent and bioavailable bioactive peptides.

  15. Highly sensitive detection of target molecules using a new fluorescence-based bead assay

    NASA Astrophysics Data System (ADS)

    Scheffler, Silvia; Strauß, Denis; Sauer, Markus

    2007-07-01

    Development of immunoassays with improved sensitivity, specificity and reliability are of major interest in modern bioanalytical research. We describe the development of a new immunomagnetic fluorescence detection (IM-FD) assay based on specific antigen/antibody interactions and on accumulation of the fluorescence signal on superparamagnetic PE beads in combination with the use of extrinsic fluorescent labels. IM-FD can be easily modified by varying the order of coatings and assay conditions. Depending on the target molecule, antibodies (ABs), entire proteins, or small protein epitopes can be used as capture molecules. The presence of target molecules is detected by fluorescence microscopy using fluorescently labeled secondary or detection antibodies. Here, we demonstrate the potential of the new assay detecting the two tumor markers IGF-I and p53 antibodies in the clinically relevant concentration range. Our data show that the fluorescence-based bead assay exhibits a large dynamic range and a high sensitivity down to the subpicomolar level.

  16. Optoelectronic System Measures Distances to Multiple Targets

    NASA Technical Reports Server (NTRS)

    Liebe, Carl Christian; Abramovici, Alexander; Bartman, Randall; Chapsky, Jacob; Schmalz, John; Coste, Keith; Litty, Edward; Lam, Raymond; Jerebets, Sergei

    2007-01-01

    An optoelectronic metrology apparatus now at the laboratory-prototype stage of development is intended to repeatedly determine distances of as much as several hundred meters, at submillimeter accuracy, to multiple targets in rapid succession. The underlying concept of optoelectronic apparatuses that can measure distances to targets is not new; such apparatuses are commonly used in general surveying and machining. However, until now such apparatuses have been, variously, constrained to (1) a single target or (2) multiple targets with a low update rate and a requirement for some a priori knowledge of target geometry. When fully developed, the present apparatus would enable measurement of distances to more than 50 targets at an update rate greater than 10 Hz, without a requirement for a priori knowledge of target geometry. The apparatus (see figure) includes a laser ranging unit (LRU) that includes an electronic camera (photo receiver), the field of view of which contains all relevant targets. Each target, mounted at a fiducial position on an object of interest, consists of a small lens at the output end of an optical fiber that extends from the object of interest back to the LRU. For each target and its optical fiber, there is a dedicated laser that is used to illuminate the target via the optical fiber. The targets are illuminated, one at a time, with laser light that is modulated at a frequency of 10.01 MHz. The modulated laser light is emitted by the target, from where it returns to the camera (photodetector), where it is detected. Both the outgoing and incoming 10.01-MHz laser signals are mixed with a 10-MHz local-oscillator to obtain beat notes at 10 kHz, and the difference between the phases of the beat notes is measured by a phase meter. This phase difference serves as a measure of the total length of the path traveled by light going out through the optical fiber and returning to the camera (photodetector) through free space. Because the portion of the path

  17. Towards free 3D end-point control for robotic-assisted human reaching using binocular eye tracking.

    PubMed

    Maimon-Dror, Roni O; Fernandez-Quesada, Jorge; Zito, Giuseppe A; Konnaris, Charalambos; Dziemian, Sabine; Faisal, A Aldo

    2017-07-01

    Eye-movements are the only directly observable behavioural signals that are highly correlated with actions at the task level, and proactive of body movements and thus reflect action intentions. Moreover, eye movements are preserved in many movement disorders leading to paralysis (or amputees) from stroke, spinal cord injury, Parkinson's disease, multiple sclerosis, and muscular dystrophy among others. Despite this benefit, eye tracking is not widely used as control interface for robotic interfaces in movement impaired patients due to poor human-robot interfaces. We demonstrate here how combining 3D gaze tracking using our GT3D binocular eye tracker with custom designed 3D head tracking system and calibration method enables continuous 3D end-point control of a robotic arm support system. The users can move their own hand to any location of the workspace by simple looking at the target and winking once. This purely eye tracking based system enables the end-user to retain free head movement and yet achieves high spatial end point accuracy in the order of 6 cm RMSE error in each dimension and standard deviation of 4 cm. 3D calibration is achieved by moving the robot along a 3 dimensional space filling Peano curve while the user is tracking it with their eyes. This results in a fully automated calibration procedure that yields several thousand calibration points versus standard approaches using a dozen points, resulting in beyond state-of-the-art 3D accuracy and precision.

  18. End-to-side and end-to-end anastomoses give similar results in cervical oesophagogastrostomy.

    PubMed

    Pierie, J P; De Graaf, P W; Poen, H; Van Der Tweel, I; Obertop, H

    1995-12-01

    To find out if there were any differences in healing between end-to-end and end-to-side anastomoses for oesophagogastrostomy. Open study with historical controls. University hospital, The Netherlands. 28 patients with end-to-end and 90 patients with end-to-side anastomoses after transhiatal oesophagectomy and partial gastrectomy for cancer of the oesophagus or oesophagogastric junction, with gastric tube reconstruction and cervical anastomosis. Leak and stricture rates, and the number of dilatations needed to relieve dysphagia. There were no significant differences in leak rates (end-to-end 4/28, 14%, and end-to-side 13/90, 14%) or anastomotic strictures (end-to-end 9/28, 32%, and end-to-side 26/90, 29%). The median number of dilatations needed to relieve dysphagia was 7 (1-33) after end-to-end and 9 (1-113) after end-to-side oesophagogastrostomy. There were no differences between the two methods of suture of cervical oesophagogastrostomy when leakage, stricture, and number of dilatations were used as criteria of good healing.

  19. Reconstitution of dynein transport to the microtubule plus end by kinesin

    PubMed Central

    Roberts, Anthony J; Goodman, Brian S; Reck-Peterson, Samara L

    2014-01-01

    Cytoplasmic dynein powers intracellular movement of cargo toward the microtubule minus end. The first step in a variety of dynein transport events is the targeting of dynein to the dynamic microtubule plus end, but the molecular mechanism underlying this spatial regulation is not understood. Here, we reconstitute dynein plus-end transport using purified proteins from S. cerevisiae and dissect the mechanism using single-molecule microscopy. We find that two proteins–homologs of Lis1 and Clip170–are sufficient to couple dynein to Kip2, a plus-end-directed kinesin. Dynein is transported to the plus end by Kip2, but is not a passive passenger, resisting its own plus-end-directed motion. Two microtubule-associated proteins, homologs of Clip170 and EB1, act as processivity factors for Kip2, helping it overcome dynein's intrinsic minus-end-directed motility. This reveals how a minimal system of proteins transports a molecular motor to the start of its track. DOI: http://dx.doi.org/10.7554/eLife.02641.001 PMID:24916158

  20. Targeted Type 1 phototherapeutic agents using azido-peptide bioconjugates

    NASA Astrophysics Data System (ADS)

    Rajagopalan, Raghavan; Achilefu, Samuel I.; Jimenez, Hermo N.; Webb, Elizabeth G.; Schmidt, Michelle A.; Bugaj, Joseph E.; Dorshow, Richard B.

    2001-07-01

    Five peptides binding to somatostatin and bombesin receptors were conjugated to 4-azido-2,3,4,6-tetrafluorophenylbenzoic acid, a Type 1 photosensitizer, at the N-terminal position. The receptor affinities were determined by competition binding assay using two different pancreatic tumor cell lines, CA20948 and AR42-J, that expresses somatostatin-2 (SST-2) and bombesin receptors receptively. All compounds exhibited high receptor specificity, i.e., the IC50 values ranged between 1.0 to 64.0 nM. These conjugates may be useful for targeted Type 1 phototherapy via the generation of nitrenes at the cell surfaces expressing these receptors.

  1. 7 CFR 782.12 - Filing FSA-750, End-Use Certificate for Wheat.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 7 2014-01-01 2014-01-01 false Filing FSA-750, End-Use Certificate for Wheat. 782.12 Section 782.12 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS END-USE CERTIFICATE PROGRAM Implementation of the End-Use...

  2. 7 CFR 782.12 - Filing FSA-750, End-Use Certificate for Wheat.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Filing FSA-750, End-Use Certificate for Wheat. 782.12 Section 782.12 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS END-USE CERTIFICATE PROGRAM Implementation of the End-Use...

  3. 7 CFR 782.12 - Filing FSA-750, End-Use Certificate for Wheat.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 7 2011-01-01 2011-01-01 false Filing FSA-750, End-Use Certificate for Wheat. 782.12 Section 782.12 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS END-USE CERTIFICATE PROGRAM Implementation of the End-Use...

  4. 7 CFR 782.12 - Filing FSA-750, End-Use Certificate for Wheat.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 7 2013-01-01 2013-01-01 false Filing FSA-750, End-Use Certificate for Wheat. 782.12 Section 782.12 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS END-USE CERTIFICATE PROGRAM Implementation of the End-Use...

  5. 7 CFR 782.12 - Filing FSA-750, End-Use Certificate for Wheat.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 7 2012-01-01 2012-01-01 false Filing FSA-750, End-Use Certificate for Wheat. 782.12 Section 782.12 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS END-USE CERTIFICATE PROGRAM Implementation of the End-Use...

  6. Functional importance of short-range binding and long-range solvent interactions in helical antifreeze peptides.

    PubMed

    Ebbinghaus, Simon; Meister, Konrad; Prigozhin, Maxim B; Devries, Arthur L; Havenith, Martina; Dzubiella, Joachim; Gruebele, Martin

    2012-07-18

    Short-range ice binding and long-range solvent perturbation both have been implicated in the activity of antifreeze proteins and antifreeze glycoproteins. We study these two mechanisms for activity of winter flounder antifreeze peptide. Four mutants are characterized by freezing point hysteresis (activity), circular dichroism (secondary structure), Förster resonance energy transfer (end-to-end rigidity), molecular dynamics simulation (structure), and terahertz spectroscopy (long-range solvent perturbation). Our results show that the short-range model is sufficient to explain the activity of our mutants, but the long-range model provides a necessary condition for activity: the most active peptides in our data set all have an extended dynamical hydration shell. It appears that antifreeze proteins and antifreeze glycoproteins have reached different evolutionary solutions to the antifreeze problem, utilizing either a few precisely positioned OH groups or a large quantity of OH groups for ice binding, assisted by long-range solvent perturbation. Copyright © 2012 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  7. Free range hens use the range more when the outdoor environment is enriched.

    PubMed

    Nagle, T A D; Glatz, P C

    2012-04-01

    To evaluate the role of using forage, shade and shelterbelts in attracting birds into the range, three trials were undertaken with free range layers both on a research facility and on commercial farms. Each of the trials on the free range research facility in South Australia used a total of 120 laying hens (Hyline Brown). Birds were housed in an eco-shelter which had 6 internal pens of equal size with a free range area adjoining the shelter. The on-farm trials were undertaken on commercial free range layer farms in the Darling Downs in Southeast Queensland with bird numbers on farms ranging from 2,000-6,800 hens. The first research trial examined the role of shaded areas in the range; the second trial examined the role of forage and the third trial examined the influence of shelterbelts in the range. These treatments were compared to a free range area with no enrichment. Aggressive feather pecking was only observed on a few occasions in all of the trials due to the low bird numbers housed. Enriching the free range environment attracted more birds into the range. Shaded areas were used by 18% of the hens with a tendency (p = 0.07) for more hens to be in the paddock. When forage was provided in paddocks more control birds (55%) were observed in the range in morning than in the afternoon (30%) while for the forage treatments 45% of the birds were in the range both during the morning and afternoon. When shelterbelts were provided there was a significantly (p<0.05) higher % of birds in the range (43% vs. 24%) and greater numbers of birds were observed in areas further away from the poultry house. The results from the on-farm trials mirrored the research trials. Overall 3 times more hens used the shaded areas than the non shaded areas, with slightly more using the shade in the morning than in the afternoon. As the environmental temperature increased the number of birds using the outdoor shade also increased. Overall 17 times more hens used the shelterbelt areas than the

  8. Post-targeting strategy for ready-to-use targeted nanodelivery post cargo loading.

    PubMed

    Zhu, J Y; Hu, J J; Zhang, M K; Yu, W Y; Zheng, D W; Wang, X Q; Feng, J; Zhang, X Z

    2017-12-14

    Based on boronate formation, this study reports a post-targeting methodology capable of readily installing versatile targeting modules onto a cargo-loaded nanoplatform in aqueous mediums. This permits the targeted nanodelivery of broad-spectrum therapeutics (drug/gene) in a ready-to-use manner while overcoming the PEGylation-dilemma that frequently occurs in conventional targeting approaches.

  9. Identification of chemogenomic features from drug–target interaction networks using interpretable classifiers

    PubMed Central

    Tabei, Yasuo; Pauwels, Edouard; Stoven, Véronique; Takemoto, Kazuhiro; Yamanishi, Yoshihiro

    2012-01-01

    Motivation: Drug effects are mainly caused by the interactions between drug molecules and their target proteins including primary targets and off-targets. Identification of the molecular mechanisms behind overall drug–target interactions is crucial in the drug design process. Results: We develop a classifier-based approach to identify chemogenomic features (the underlying associations between drug chemical substructures and protein domains) that are involved in drug–target interaction networks. We propose a novel algorithm for extracting informative chemogenomic features by using L1 regularized classifiers over the tensor product space of possible drug–target pairs. It is shown that the proposed method can extract a very limited number of chemogenomic features without loosing the performance of predicting drug–target interactions and the extracted features are biologically meaningful. The extracted substructure–domain association network enables us to suggest ligand chemical fragments specific for each protein domain and ligand core substructures important for a wide range of protein families. Availability: Softwares are available at the supplemental website. Contact: yamanishi@bioreg.kyushu-u.ac.jp Supplementary Information: Datasets and all results are available at http://cbio.ensmp.fr/~yyamanishi/l1binary/ . PMID:22962471

  10. Advances in image compression and automatic target recognition; Proceedings of the Meeting, Orlando, FL, Mar. 30, 31, 1989

    NASA Technical Reports Server (NTRS)

    Tescher, Andrew G. (Editor)

    1989-01-01

    Various papers on image compression and automatic target recognition are presented. Individual topics addressed include: target cluster detection in cluttered SAR imagery, model-based target recognition using laser radar imagery, Smart Sensor front-end processor for feature extraction of images, object attitude estimation and tracking from a single video sensor, symmetry detection in human vision, analysis of high resolution aerial images for object detection, obscured object recognition for an ATR application, neural networks for adaptive shape tracking, statistical mechanics and pattern recognition, detection of cylinders in aerial range images, moving object tracking using local windows, new transform method for image data compression, quad-tree product vector quantization of images, predictive trellis encoding of imagery, reduced generalized chain code for contour description, compact architecture for a real-time vision system, use of human visibility functions in segmentation coding, color texture analysis and synthesis using Gibbs random fields.

  11. Orion MPCV GN and C End-to-End Phasing Tests

    NASA Technical Reports Server (NTRS)

    Neumann, Brian C.

    2013-01-01

    End-to-end integration tests are critical risk reduction efforts for any complex vehicle. Phasing tests are an end-to-end integrated test that validates system directional phasing (polarity) from sensor measurement through software algorithms to end effector response. Phasing tests are typically performed on a fully integrated and assembled flight vehicle where sensors are stimulated by moving the vehicle and the effectors are observed for proper polarity. Orion Multi-Purpose Crew Vehicle (MPCV) Pad Abort 1 (PA-1) Phasing Test was conducted from inertial measurement to Launch Abort System (LAS). Orion Exploration Flight Test 1 (EFT-1) has two end-to-end phasing tests planned. The first test from inertial measurement to Crew Module (CM) reaction control system thrusters uses navigation and flight control system software algorithms to process commands. The second test from inertial measurement to CM S-Band Phased Array Antenna (PAA) uses navigation and communication system software algorithms to process commands. Future Orion flights include Ascent Abort Flight Test 2 (AA-2) and Exploration Mission 1 (EM-1). These flights will include additional or updated sensors, software algorithms and effectors. This paper will explore the implementation of end-to-end phasing tests on a flight vehicle which has many constraints, trade-offs and compromises. Orion PA-1 Phasing Test was conducted at White Sands Missile Range (WSMR) from March 4-6, 2010. This test decreased the risk of mission failure by demonstrating proper flight control system polarity. Demonstration was achieved by stimulating the primary navigation sensor, processing sensor data to commands and viewing propulsion response. PA-1 primary navigation sensor was a Space Integrated Inertial Navigation System (INS) and Global Positioning System (GPS) (SIGI) which has onboard processing, INS (3 accelerometers and 3 rate gyros) and no GPS receiver. SIGI data was processed by GN&C software into thrust magnitude and

  12. Factors affecting family satisfaction with inpatient end-of-life care.

    PubMed

    Sadler, Erin; Hales, Brigette; Henry, Blair; Xiong, Wei; Myers, Jeff; Wynnychuk, Lesia; Taggar, Ru; Heyland, Daren; Fowler, Robert

    2014-01-01

    Little data exists addressing satisfaction with end-of-life care among hospitalized patients, as they and their family members are systematically excluded from routine satisfaction surveys. It is imperative that we closely examine patient and institution factors associated with quality end-of-life care and determine high-priority target areas for quality improvement. Between September 1, 2010 and January 1, 2012 the Canadian Health care Evaluation Project (CANHELP) Bereavement Questionnaire was mailed to the next-of-kin of recently deceased inpatients to seek factors associated with satisfaction with end-of-life care. The primary outcome was the global rating of satisfaction. Secondary outcomes included rates of actual versus preferred location of death, associations between demographic factors and global satisfaction, and identification of targets for quality improvement. Response rate was 33% among 275 valid addresses. Overall, 67.4% of respondents were very or completely satisfied with the overall quality of care their relative received. However, 71.4% of respondents who thought their relative did not die in their preferred location favoured an out-of-hospital location of death. A common location of death was the intensive care unit (45.7%); however, this was not the preferred location of death for 47.6% of such patients. Multivariate Poisson regression analysis showed respondents who believed their relative died in their preferred location were 1.7 times more likely to be satisfied with the end-of-life care that was provided (p = 0.001). Items identified as high-priority targets for improvement included: relationships with, and characteristics of health care professionals; illness management; communication; and end-of-life decision-making. Nearly three-quarters of recently deceased inpatients would have preferred an out-of-hospital death. Intensive care units were a common, but not preferred, location of in-hospital deaths. Family satisfaction with end

  13. Commercial equipment loads: End-Use Load and Consumer Assessment Program (ELCAP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pratt, R.G.; Williamson, M.A.; Richman, E.E.

    1990-07-01

    The Office of Energy Resources of the Bonneville Power Administration is generally responsible for the agency's power and conservation resource planning. As associated responsibility which supports a variety of office functions is the analysis of historical trends in and determinants of energy consumption. The Office of Energy Resources' End-Use Research Section operates a comprehensive data collection program to provide pertinent information to support demand-side planning, load forecasting, and demand-side program development and delivery. Part of this on-going program is known as the End-Use Load and Consumer Assessment Program (ELCAP), an effort designed to collect electricity usage data through direct monitoringmore » of end-use loads in buildings. This program is conducted for Bonneville by the Pacific Northwest Laboratory. This report provides detailed information on electricity consumption of miscellaneous equipment from the commercial portion of ELCAP. Miscellaneous equipment includes all commercial end-uses except heating, ventilating, air conditioning, and central lighting systems. Some examples of end-uses covered in this report are office equipment, computers, task lighting, refrigeration, and food preparation. Electricity consumption estimates, in kilowatt-hours per square food per year, are provided for each end-use by building type. The following types of buildings are covered: office, retail, restaurant, grocery, warehouse, school, university, and hotel/motel. 6 refs., 35 figs., 12 tabs.« less

  14. Targeting water and energy conservation using big data

    NASA Astrophysics Data System (ADS)

    Escriva-Bou, A.; Pulido-Velazquez, M.; Lund, J. R.

    2016-12-01

    Water conservation is often the most cost effective source of additional water supply for water stressed regions to maintain supply reliability with increasing population and/or demands, or shorter-term droughts. In previous research we demonstrated how including energy savings of conserved water can increase willingness to adopt conservation measures, at the same time that increases energy and GHG emissions savings. But the capacity to save water, energy and GHG emissions depends fundamentally in the economic benefits for customers and utilities. Utilities have traditionally used rebates, subsidies or incentives to enhance water conservation. But the economic benefits originated by these rebates depend on the actual savings of the water, energy and GHG emissions. A crucial issue that is not considered in the financial analysis of these rebates is the heterogeneity in water consumption, resulting in rebating households that actually do not need improvements in certain appliances. Smart meters with end-use disaggregation allow to consider this heterogeneity and to target rebates. By using an optimization approach that minimizes water and energy residential costs—accounting for retrofit costs and individual benefits according to previous levels of consumption—we are able to assess economically optimal rebate programs both for customers and utilities. Three programs are considered: first, same economic incentives are provided to all households and then they do their optimal decisions; second, traditional appliance-focused rebates are assessed; and third, utilities provide only rebates to those households that maximize water, energy or GHG emissions savings. Results show that the most economically efficient options for households are not the best options for utilities, and that traditional appliance-focused rebates are much less optimal than targeted rebates.

  15. 15 CFR 744.4 - Restrictions on certain chemical and biological weapons end-uses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... biological weapons end-uses. 744.4 Section 744.4 Commerce and Foreign Trade Regulations Relating to Commerce... ADMINISTRATION REGULATIONS CONTROL POLICY: END-USER AND END-USE BASED § 744.4 Restrictions on certain chemical and biological weapons end-uses. (a) General prohibition. In addition to the license requirements for...

  16. 15 CFR 744.4 - Restrictions on certain chemical and biological weapons end-uses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... biological weapons end-uses. 744.4 Section 744.4 Commerce and Foreign Trade Regulations Relating to Commerce... ADMINISTRATION REGULATIONS CONTROL POLICY: END-USER AND END-USE BASED § 744.4 Restrictions on certain chemical and biological weapons end-uses. (a) General prohibition. In addition to the license requirements for...

  17. 15 CFR 744.4 - Restrictions on certain chemical and biological weapons end-uses.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... biological weapons end-uses. 744.4 Section 744.4 Commerce and Foreign Trade Regulations Relating to Commerce... ADMINISTRATION REGULATIONS CONTROL POLICY: END-USER AND END-USE BASED § 744.4 Restrictions on certain chemical and biological weapons end-uses. (a) General prohibition. In addition to the license requirements for...

  18. 15 CFR 744.4 - Restrictions on certain chemical and biological weapons end-uses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... biological weapons end-uses. 744.4 Section 744.4 Commerce and Foreign Trade Regulations Relating to Commerce... ADMINISTRATION REGULATIONS CONTROL POLICY: END-USER AND END-USE BASED § 744.4 Restrictions on certain chemical and biological weapons end-uses. (a) General prohibition. In addition to the license requirements for...

  19. 15 CFR 744.4 - Restrictions on certain chemical and biological weapons end-uses.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... biological weapons end-uses. 744.4 Section 744.4 Commerce and Foreign Trade Regulations Relating to Commerce... ADMINISTRATION REGULATIONS CONTROL POLICY: END-USER AND END-USE BASED § 744.4 Restrictions on certain chemical and biological weapons end-uses. (a) General prohibition. In addition to the license requirements for...

  20. Prevalence of electronic nicotine delivery systems (ENDS) use among youth globally: a systematic review and meta-analysis of country level data.

    PubMed

    Yoong, Sze Lin; Stockings, Emily; Chai, Li Kheng; Tzelepis, Flora; Wiggers, John; Oldmeadow, Christopher; Paul, Christine; Peruga, Armando; Kingsland, Melanie; Attia, John; Wolfenden, Luke

    2018-06-01

    To describe the prevalence and change in prevalence of electronic nicotine delivery systems (ENDS) use in youth by country and combustible smoking status. Databases and the grey literature were systematically searched to December 2015. Studies describing the prevalence of ENDS use in the general population aged ≤20 years in a defined geographical region were included. Where multiple estimates were available within countries, prevalence estimates of ENDS use were pooled for each country separately. Data from 27 publications (36 surveys) from 13 countries were included. The prevalence of ENDS ever use in 2013-2015 among youth were highest in Poland (62.1%; 95%CI: 59.9-64.2%), and lowest in Italy (5.9%; 95%CI: 3.3-9.2%). Among non-smoking youth, the prevalence of ENDS ever use in 2013-2015 varied, ranging from 4.2% (95%CI: 3.8-4.6%) in the US to 14.0% in New Zealand (95%CI: 12.7-15.4%). The prevalence of ENDS ever use among current tobacco smoking youth was the highest in Canada (71.9%, 95%CI: 70.9-72.8%) and lowest in Italy (29.9%, 95%CI: 18.5-42.5%). Between 2008 and 2015, ENDS ever use among youth increased in Poland, Korea, New Zealand and the US; decreased in Italy and Canada; and remained stable in the UK. There is considerable heterogeneity in ENDS use among youth globally across countries and also between current smokers and non-smokers. Implications for public health: Population-level survey data on ENDS use is needed to inform public health policy and messaging globally. © 2018 The Authors.

  1. The Kepler End-to-End Model: Creating High-Fidelity Simulations to Test Kepler Ground Processing

    NASA Technical Reports Server (NTRS)

    Bryson, Stephen T.; Jenkins, Jon M.; Peters, Dan J.; Tenenbaum, Peter P.; Klaus, Todd C.; Gunter, Jay P.; Cote, Miles T.; Caldwell, Douglas A.

    2010-01-01

    The Kepler mission is designed to detect the transit of Earth-like planets around Sun-like stars by observing 100,000 stellar targets. Developing and testing the Kepler ground-segment processing system, in particular the data analysis pipeline, requires high-fidelity simulated data. This simulated data is provided by the Kepler End-to-End Model (ETEM). ETEM simulates the astrophysics of planetary transits and other phenomena, properties of the Kepler spacecraft and the format of the downlinked data. Major challenges addressed by ETEM include the rapid production of large amounts of simulated data, extensibility and maintainability.

  2. Classification of video sequences into chosen generalized use classes of target size and lighting level.

    PubMed

    Leszczuk, Mikołaj; Dudek, Łukasz; Witkowski, Marcin

    The VQiPS (Video Quality in Public Safety) Working Group, supported by the U.S. Department of Homeland Security, has been developing a user guide for public safety video applications. According to VQiPS, five parameters have particular importance influencing the ability to achieve a recognition task. They are: usage time-frame, discrimination level, target size, lighting level, and level of motion. These parameters form what are referred to as Generalized Use Classes (GUCs). The aim of our research was to develop algorithms that would automatically assist classification of input sequences into one of the GUCs. Target size and lighting level parameters were approached. The experiment described reveals the experts' ambiguity and hesitation during the manual target size determination process. However, the automatic methods developed for target size classification make it possible to determine GUC parameters with 70 % compliance to the end-users' opinion. Lighting levels of the entire sequence can be classified with an efficiency reaching 93 %. To make the algorithms available for use, a test application has been developed. It is able to process video files and display classification results, the user interface being very simple and requiring only minimal user interaction.

  3. Front-End Board with Cyclone V as a Test High-Resolution Platform for the Auger_Beyond_2015 Front End Electronics

    NASA Astrophysics Data System (ADS)

    Szadkowski, Zbigniew

    2015-06-01

    The surface detector (SD) array of the Pierre Auger Observatory needs an upgrade which allows space for more complex triggers with higher bandwidth and greater dynamic range. To this end this paper presents a front-end board (FEB) with the largest Cyclone V E FPGA 5CEFA9F31I7N. It supports eight channels sampled with max. 250 MSps@14-bit resolution. Considered sampling for the SD is 120 MSps; however, the FEB has been developed with external anti-aliasing filters to retain maximal flexibility. Six channels are targeted at the SD, two are reserved for other experiments like: Auger Engineering Radio Array and additional muon counters. The FEB is an intermediate design plugged into a unified board communicating with a micro-controller at 40 MHz; however, it provides 250 MSPs sampling with an 18-bit dynamic range, is equipped with a virtual NIOS processor and supports 256 MB of SDRAM as well as an implemented spectral trigger based on the discrete cosine transform for detection of very inclined “old” showers. The FEB can also support neural network development for detection of “young” showers, potentially generated by neutrinos. A single FEB was already tested in the Auger surface detector in Malargüe (Argentina) for 120 and 160 MSps. Preliminary tests showed perfect stability of data acquisition for sampling frequency three or four times greater. They allowed optimization of the design before deployment of seven or eight FEBs for several months of continuous tests in the engineering array.

  4. End of Life: An Overview

    ERIC Educational Resources Information Center

    Toner, Mary Ann; Shadden, Barbara B.

    2012-01-01

    Speech-language pathologists (SLPs) provide services to patients confronting the end of life (EOL) in a variety of settings. Instead of targeting improvement of health or sustaining life, EOL services focus primarily on quality of life. Although SLPs may not consider themselves core members of the health care team providing EOL services, the…

  5. Image gathering, coding, and processing: End-to-end optimization for efficient and robust acquisition of visual information

    NASA Technical Reports Server (NTRS)

    Huck, Friedrich O.; Fales, Carl L.

    1990-01-01

    Researchers are concerned with the end-to-end performance of image gathering, coding, and processing. The applications range from high-resolution television to vision-based robotics, wherever the resolution, efficiency and robustness of visual information acquisition and processing are critical. For the presentation at this workshop, it is convenient to divide research activities into the following two overlapping areas: The first is the development of focal-plane processing techniques and technology to effectively combine image gathering with coding, with an emphasis on low-level vision processing akin to the retinal processing in human vision. The approach includes the familiar Laplacian pyramid, the new intensity-dependent spatial summation, and parallel sensing/processing networks. Three-dimensional image gathering is attained by combining laser ranging with sensor-array imaging. The second is the rigorous extension of information theory and optimal filtering to visual information acquisition and processing. The goal is to provide a comprehensive methodology for quantitatively assessing the end-to-end performance of image gathering, coding, and processing.

  6. Nonlinear dynamic range transformation in visual communication channels.

    PubMed

    Alter-Gartenberg, R

    1996-01-01

    The article evaluates nonlinear dynamic range transformation in the context of the end-to-end continuous-input/discrete processing/continuous-display imaging process. Dynamic range transformation is required when we have the following: (i) the wide dynamic range encountered in nature is compressed into the relatively narrow dynamic range of the display, particularly for spatially varying irradiance (e.g., shadow); (ii) coarse quantization is expanded to the wider dynamic range of the display; and (iii) nonlinear tone scale transformation compensates for the correction in the camera amplifier.

  7. Experience of using MOSFET detectors for dose verification measurements in an end-to-end 192Ir brachytherapy quality assurance system.

    PubMed

    Persson, Maria; Nilsson, Josef; Carlsson Tedgren, Åsa

    Establishment of an end-to-end system for the brachytherapy (BT) dosimetric chain could be valuable in clinical quality assurance. Here, the development of such a system using MOSFET (metal oxide semiconductor field effect transistor) detectors and experience gained during 2 years of use are reported with focus on the performance of the MOSFET detectors. A bolus phantom was constructed with two implants, mimicking prostate and head & neck treatments, using steel needles and plastic catheters to guide the 192 Ir source and house the MOSFET detectors. The phantom was taken through the BT treatment chain from image acquisition to dose evaluation. During the 2-year evaluation-period, delivered doses were verified a total of 56 times using MOSFET detectors which had been calibrated in an external 60 Co beam. An initial experimental investigation on beam quality differences between 192 Ir and 60 Co is reported. The standard deviation in repeated MOSFET measurements was below 3% in the six measurement points with dose levels above 2 Gy. MOSFET measurements overestimated treatment planning system doses by 2-7%. Distance-dependent experimental beam quality correction factors derived in a phantom of similar size as that used for end-to-end tests applied on a time-resolved measurement improved the agreement. MOSFET detectors provide values stable over time and function well for use as detectors for end-to-end quality assurance purposes in 192 Ir BT. Beam quality correction factors should address not only distance from source but also phantom dimensions. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  8. Noise pair velocity and range echo location system

    DOEpatents

    Erskine, D.J.

    1999-02-16

    An echo-location method for microwaves, sound and light capable of using incoherent and arbitrary waveforms of wide bandwidth to measure velocity and range (and target size) simultaneously to high resolution is disclosed. Two interferometers having very long and nearly equal delays are used in series with the target interposed. The delays can be longer than the target range of interest. The first interferometer imprints a partial coherence on an initially incoherent source which allows autocorrelation to be performed on the reflected signal to determine velocity. A coherent cross-correlation subsequent to the second interferometer with the source determines a velocity discriminated range. Dithering the second interferometer identifies portions of the cross-correlation belonging to a target apart from clutter moving at a different velocity. The velocity discrimination is insensitive to all slowly varying distortions in the signal path. Speckle in the image of target and antenna lobing due to parasitic reflections is minimal for an incoherent source. An arbitrary source which varies its spectrum dramatically and randomly from pulse to pulse creates a radar elusive to jamming. Monochromatic sources which jigger in frequency from pulse to pulse or combinations of monochromatic sources can simulate some benefits of incoherent broadband sources. Clutter which has a symmetrical velocity spectrum will self-cancel for short wavelengths, such as the apparent motion of ground surrounding target from a sidelooking airborne antenna. 46 figs.

  9. Noise pair velocity and range echo location system

    DOEpatents

    Erskine, David J.

    1999-01-01

    An echo-location method for microwaves, sound and light capable of using incoherent and arbitrary waveforms of wide bandwidth to measure velocity and range (and target size) simultaneously to high resolution. Two interferometers having very long and nearly equal delays are used in series with the target interposed. The delays can be longer than the target range of interest. The first interferometer imprints a partial coherence on an initially incoherent source which allows autocorrelation to be performed on the reflected signal to determine velocity. A coherent cross-correlation subsequent to the second interferometer with the source determines a velocity discriminated range. Dithering the second interferometer identifies portions of the cross-correlation belonging to a target apart from clutter moving at a different velocity. The velocity discrimination is insensitive to all slowly varying distortions in the signal path. Speckle in the image of target and antenna lobing due to parasitic reflections is minimal for an incoherent source. An arbitrary source which varies its spectrum dramatically and randomly from pulse to pulse creates a radar elusive to jamming. Monochromatic sources which jigger in frequency from pulse to pulse or combinations of monochromatic sources can simulate some benefits of incoherent broadband sources. Clutter which has a symmetrical velocity spectrum will self-cancel for short wavelengths, such as the apparent motion of ground surrounding target from a sidelooking airborne antenna.

  10. Modeling and simulation of satellite subsystems for end-to-end spacecraft modeling

    NASA Astrophysics Data System (ADS)

    Schum, William K.; Doolittle, Christina M.; Boyarko, George A.

    2006-05-01

    During the past ten years, the Air Force Research Laboratory (AFRL) has been simultaneously developing high-fidelity spacecraft payload models as well as a robust distributed simulation environment for modeling spacecraft subsystems. Much of this research has occurred in the Distributed Architecture Simulation Laboratory (DASL). AFRL developers working in the DASL have effectively combined satellite power, attitude pointing, and communication link analysis subsystem models with robust satellite sensor models to create a first-order end-to-end satellite simulation capability. The merging of these two simulation areas has advanced the field of spacecraft simulation, design, and analysis, and enabled more in-depth mission and satellite utility analyses. A core capability of the DASL is the support of a variety of modeling and analysis efforts, ranging from physics and engineering-level modeling to mission and campaign-level analysis. The flexibility and agility of this simulation architecture will be used to support space mission analysis, military utility analysis, and various integrated exercises with other military and space organizations via direct integration, or through DOD standards such as Distributed Interaction Simulation. This paper discusses the results and lessons learned in modeling satellite communication link analysis, power, and attitude control subsystems for an end-to-end satellite simulation. It also discusses how these spacecraft subsystem simulations feed into and support military utility and space mission analyses.

  11. Jake Matijevic Contact Target for Curiosity

    NASA Image and Video Library

    2012-09-19

    The drive by NASA Mars rover Curiosity during the mission 43rd Martian day ended with this rock front of the rover. The rover team has assessed it as a suitable target for the first use of Curiosity contact instruments on a rock.

  12. Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

    NASA Technical Reports Server (NTRS)

    Kubalak, David; Hadjimichael, Theodore; Ohl, Raymond; Slotwinski, Anthony; Telfer, Randal; Hayden, Joseph

    2012-01-01

    Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a

  13. Addressing the targeting range of the ABILHAND-56 in relapsing-remitting multiple sclerosis: A mixed methods psychometric study.

    PubMed

    Cleanthous, Sophie; Strzok, Sara; Pompilus, Farrah; Cano, Stefan; Marquis, Patrick; Cohan, Stanley; Goldman, Myla D; Kresa-Reahl, Kiren; Petrillo, Jennifer; Castrillo-Viguera, Carmen; Cadavid, Diego; Chen, Shih-Yin

    2018-01-01

    ABILHAND, a manual ability patient-reported outcome instrument originally developed for stroke patients, has been used in multiple sclerosis clinical trials; however, psychometric analyses indicated the measure's limited measurement range and precision in higher-functioning multiple sclerosis patients. The purpose of this study was to identify candidate items to expand the measurement range of the ABILHAND-56, thus improving its ability to detect differences in manual ability in higher-functioning multiple sclerosis patients. A step-wise mixed methods design strategy was used, comprising two waves of patient interviews, a combination of qualitative (concept elicitation and cognitive debriefing) and quantitative (Rasch measurement theory) analytic techniques, and consultation interviews with three clinical neurologists specializing in multiple sclerosis. Original ABILHAND was well understood in this context of use. Eighty-two new manual ability concepts were identified. Draft supplementary items were generated and refined with patient and neurologist input. Rasch measurement theory psychometric analysis indicated supplementary items improved targeting to higher-functioning multiple sclerosis patients and measurement precision. The final pool of Early Multiple Sclerosis Manual Ability items comprises 20 items. The synthesis of qualitative and quantitative methods used in this study improves the ABILHAND content validity to more effectively identify manual ability changes in early multiple sclerosis and potentially help determine treatment effect in higher-functioning patients in clinical trials.

  14. Genetic dissection of end-use quality traits in adapted soft white winter wheat

    USDA-ARS?s Scientific Manuscript database

    Soft white winter wheat is used in foreign markets for various end products requiring specific end-use quality profiles. Phenotyping for end-use quality traits using can be destructive, costly, and time-consuming, so it is advantageous to use molecular markers to select experimental lines with supe...

  15. Programmable near-infrared ranging system

    DOEpatents

    Everett, Jr., Hobart R.

    1989-01-01

    A high angular resolution ranging system particularly suitable for indoor plications involving mobile robot navigation and collision avoidance uses a programmable array of light emitters that can be sequentially incremented by a microprocessor. A plurality of adjustable level threshold detectors are used in an optical receiver for detecting the threshold level of the light echoes produced when light emitted from one or more of the emitters is reflected by a target or object in the scan path of the ranging system.

  16. RNA-Targeted Therapeutics.

    PubMed

    Crooke, Stanley T; Witztum, Joseph L; Bennett, C Frank; Baker, Brenda F

    2018-04-03

    RNA-targeted therapies represent a platform for drug discovery involving chemically modified oligonucleotides, a wide range of cellular RNAs, and a novel target-binding motif, Watson-Crick base pairing. Numerous hurdles considered by many to be impassable have been overcome. Today, four RNA-targeted therapies are approved for commercial use for indications as diverse as Spinal Muscular Atrophy (SMA) and reduction of low-density lipoprotein cholesterol (LDL-C) and by routes of administration including subcutaneous, intravitreal, and intrathecal delivery. The technology is efficient and supports approaching "undruggable" targets. Three additional agents are progressing through registration, and more are in clinical development, representing several chemical and structural classes. Moreover, progress in understanding the molecular mechanisms by which these drugs work has led to steadily better clinical performance and a wide range of mechanisms that may be exploited for therapeutic purposes. Here we summarize the progress, future challenges, and opportunities for this drug discovery platform. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Improved Range Estimation Model for Three-Dimensional (3D) Range Gated Reconstruction

    PubMed Central

    Chua, Sing Yee; Guo, Ningqun; Tan, Ching Seong; Wang, Xin

    2017-01-01

    Accuracy is an important measure of system performance and remains a challenge in 3D range gated reconstruction despite the advancement in laser and sensor technology. The weighted average model that is commonly used for range estimation is heavily influenced by the intensity variation due to various factors. Accuracy improvement in term of range estimation is therefore important to fully optimise the system performance. In this paper, a 3D range gated reconstruction model is derived based on the operating principles of range gated imaging and time slicing reconstruction, fundamental of radiant energy, Laser Detection And Ranging (LADAR), and Bidirectional Reflection Distribution Function (BRDF). Accordingly, a new range estimation model is proposed to alleviate the effects induced by distance, target reflection, and range distortion. From the experimental results, the proposed model outperforms the conventional weighted average model to improve the range estimation for better 3D reconstruction. The outcome demonstrated is of interest to various laser ranging applications and can be a reference for future works. PMID:28872589

  18. Verification of target motion effects on SAR imagery using the Gotcha GMTI challenge dataset

    NASA Astrophysics Data System (ADS)

    Hack, Dan E.; Saville, Michael A.

    2010-04-01

    This paper investigates the relationship between a ground moving target's kinematic state and its SAR image. While effects such as cross-range offset, defocus, and smearing appear well understood, their derivations in the literature typically employ simplifications of the radar/target geometry and assume point scattering targets. This study adopts a geometrical model for understanding target motion effects in SAR imagery, termed the target migration path, and focuses on experimental verification of predicted motion effects using both simulated and empirical datasets based on the Gotcha GMTI challenge dataset. Specifically, moving target imagery is generated from three data sources: first, simulated phase history for a moving point target; second, simulated phase history for a moving vehicle derived from a simulated Mazda MPV X-band signature; and third, empirical phase history from the Gotcha GMTI challenge dataset. Both simulated target trajectories match the truth GPS target position history from the Gotcha GMTI challenge dataset, allowing direct comparison between all three imagery sets and the predicted target migration path. This paper concludes with a discussion of the parallels between the target migration path and the measurement model within a Kalman filtering framework, followed by conclusions.

  19. Scale-up of high specific activity 186gRe production using graphite-encased thick 186W targets and demonstration of an efficient target recycling process

    DOE PAGES

    Balkin, Ethan R.; Gagnon, Katherine; Dorman, Eric; ...

    2017-08-18

    Production of high specific activity 186gRe is of interest for development of theranostic radiopharmaceuticals. Previous studies have shown that high specific activity 186gRe can be obtained by cyclotron irradiation of enriched 186W via the 186W(d,2n) 186gRe reaction, but most irradiations were conducted at low beam currents and for short durations. In this paper, enriched 186W metal targets were irradiated at high incident deuteron beam currents to demonstrate production rates and contaminants produced when using thick targets. Full-stopping thick targets, as determined using SRIM, were prepared by uniaxial pressing of powdered natural abundance W metal or 96.86% enriched 186W metal encasedmore » between two layers of graphite flakes for target material stabilization. An assessment of structural integrity was made on each target preparation. To assess the performance of graphite-encased thick 186W metal targets, along with the impact of encasing on the separation chemistry, targets were first irradiated using a 22 MeV deuteron beam for 10 min at 10, 20, and 27 μA, with an estimated nominal deuteron energy of 18.7 MeV on the 186W target material (after energy degradation correction from top graphite layer). Gamma-ray spectrometry was performed post EOB on all targets to assess production yields and radionuclidic byproducts. The investigation also evaluated a method to recover and recycle enriched target material from a column isolation procedure. Material composition analyses of target materials, pass-through/wash solutions and recycling process isolates were conducted with SEM, FTIR, XRD, EDS and ICP-MS spectrometry. Finally, to demonstrate scaled-up production, a graphite-encased 186W target made from recycled 186W was irradiated for ~2 h with 18.7 MeV deuterons at a beam current of 27 μA to provide 0.90 GBq (24.3 mCi) of 186gRe, decay-corrected to the end of bombardment. ICP-MS analysis of the isolated 186gRe solution provided data that indicated the

  20. Scale-up of high specific activity 186gRe production using graphite-encased thick 186W targets and demonstration of an efficient target recycling process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balkin, Ethan R.; Gagnon, Katherine; Dorman, Eric

    Production of high specific activity 186gRe is of interest for development of theranostic radiopharmaceuticals. Previous studies have shown that high specific activity 186gRe can be obtained by cyclotron irradiation of enriched 186W via the 186W(d,2n) 186gRe reaction, but most irradiations were conducted at low beam currents and for short durations. In this paper, enriched 186W metal targets were irradiated at high incident deuteron beam currents to demonstrate production rates and contaminants produced when using thick targets. Full-stopping thick targets, as determined using SRIM, were prepared by uniaxial pressing of powdered natural abundance W metal or 96.86% enriched 186W metal encasedmore » between two layers of graphite flakes for target material stabilization. An assessment of structural integrity was made on each target preparation. To assess the performance of graphite-encased thick 186W metal targets, along with the impact of encasing on the separation chemistry, targets were first irradiated using a 22 MeV deuteron beam for 10 min at 10, 20, and 27 μA, with an estimated nominal deuteron energy of 18.7 MeV on the 186W target material (after energy degradation correction from top graphite layer). Gamma-ray spectrometry was performed post EOB on all targets to assess production yields and radionuclidic byproducts. The investigation also evaluated a method to recover and recycle enriched target material from a column isolation procedure. Material composition analyses of target materials, pass-through/wash solutions and recycling process isolates were conducted with SEM, FTIR, XRD, EDS and ICP-MS spectrometry. Finally, to demonstrate scaled-up production, a graphite-encased 186W target made from recycled 186W was irradiated for ~2 h with 18.7 MeV deuterons at a beam current of 27 μA to provide 0.90 GBq (24.3 mCi) of 186gRe, decay-corrected to the end of bombardment. ICP-MS analysis of the isolated 186gRe solution provided data that indicated the

  1. Tumble Graphs: Avoiding Misleading End Point Extrapolation When Graphing Interactions From a Moderated Multiple Regression Analysis

    ERIC Educational Resources Information Center

    Bodner, Todd E.

    2016-01-01

    This article revisits how the end points of plotted line segments should be selected when graphing interactions involving a continuous target predictor variable. Under the standard approach, end points are chosen at ±1 or 2 standard deviations from the target predictor mean. However, when the target predictor and moderator are correlated or the…

  2. Phage protein-targeted cancer nanomedicines

    PubMed Central

    Petrenko, V.A.; Jayanna, P.K.

    2015-01-01

    Nanoencapsulation of anticancer drugs improves their therapeutic indices by virtue of the enhanced permeation and retention effect which achieves passive targeting of nanoparticles in tumors. This effect can be significantly enhanced by active targeting of nanovehicles to tumors. Numerous ligands have been proposed and used in various studies with peptides being considered attractive alternatives to antibodies. This is further reinforced by the availability of peptide phage display libraries which offer an unlimited reservoir of target-specific probes. In particular landscape phages with multivalent display of target-specific peptides which enable the phage particle itself to become a nanoplatform creates a paradigm for high throughput selection of nanoprobes setting the stage for personalized cancer management. Despite its promise, this conjugate of combinatorial chemistry and nanotechnology has not made a significant clinical impact in cancer management due to a lack of using robust processes that facilitate scale-up and manufacturing. To this end we proposed the use of phage fusion protein as the navigating modules of novel targeted nanomedicine platforms which are described in this review. PMID:24269681

  3. End-to-End Beam Simulations for the New Muon G-2 Experiment at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Korostelev, Maxim; Bailey, Ian; Herrod, Alexander

    2016-06-01

    The aim of the new muon g-2 experiment at Fermilab is to measure the anomalous magnetic moment of the muon with an unprecedented uncertainty of 140 ppb. A beam of positive muons required for the experiment is created by pion decay. Detailed studies of the beam dynamics and spin polarization of the muons are important to predict systematic uncertainties in the experiment. In this paper, we present the results of beam simulations and spin tracking from the pion production target to the muon storage ring. The end-to-end beam simulations are developed in Bmad and include the processes of particle decay,more » collimation (with accurate representation of all apertures) and spin tracking.« less

  4. A Pedestrian Detection Scheme Using a Coherent Phase Difference Method Based on 2D Range-Doppler FMCW Radar

    PubMed Central

    Hyun, Eugin; Jin, Young-Seok; Lee, Jong-Hun

    2016-01-01

    For an automotive pedestrian detection radar system, fast-ramp based 2D range-Doppler Frequency Modulated Continuous Wave (FMCW) radar is effective for distinguishing between moving targets and unwanted clutter. However, when a weak moving target such as a pedestrian exists together with strong clutter, the pedestrian may be masked by the side-lobe of the clutter even though they are notably separated in the Doppler dimension. To prevent this problem, one popular solution is the use of a windowing scheme with a weighting function. However, this method leads to a spread spectrum, so the pedestrian with weak signal power and slow Doppler may also be masked by the main-lobe of clutter. With a fast-ramp based FMCW radar, if the target is moving, the complex spectrum of the range- Fast Fourier Transform (FFT) is changed with a constant phase difference over ramps. In contrast, the clutter exhibits constant phase irrespective of the ramps. Based on this fact, in this paper we propose a pedestrian detection for highly cluttered environments using a coherent phase difference method. By detecting the coherent phase difference from the complex spectrum of the range-FFT, we first extract the range profile of the moving pedestrians. Then, through the Doppler FFT, we obtain the 2D range-Doppler map for only the pedestrian. To test the proposed detection scheme, we have developed a real-time data logging system with a 24 GHz FMCW transceiver. In laboratory tests, we verified that the signal processing results from the proposed method were much better than those expected from the conventional 2D FFT-based detection method. PMID:26805835

  5. A Pedestrian Detection Scheme Using a Coherent Phase Difference Method Based on 2D Range-Doppler FMCW Radar.

    PubMed

    Hyun, Eugin; Jin, Young-Seok; Lee, Jong-Hun

    2016-01-20

    For an automotive pedestrian detection radar system, fast-ramp based 2D range-Doppler Frequency Modulated Continuous Wave (FMCW) radar is effective for distinguishing between moving targets and unwanted clutter. However, when a weak moving target such as a pedestrian exists together with strong clutter, the pedestrian may be masked by the side-lobe of the clutter even though they are notably separated in the Doppler dimension. To prevent this problem, one popular solution is the use of a windowing scheme with a weighting function. However, this method leads to a spread spectrum, so the pedestrian with weak signal power and slow Doppler may also be masked by the main-lobe of clutter. With a fast-ramp based FMCW radar, if the target is moving, the complex spectrum of the range- Fast Fourier Transform (FFT) is changed with a constant phase difference over ramps. In contrast, the clutter exhibits constant phase irrespective of the ramps. Based on this fact, in this paper we propose a pedestrian detection for highly cluttered environments using a coherent phase difference method. By detecting the coherent phase difference from the complex spectrum of the range-FFT, we first extract the range profile of the moving pedestrians. Then, through the Doppler FFT, we obtain the 2D range-Doppler map for only the pedestrian. To test the proposed detection scheme, we have developed a real-time data logging system with a 24 GHz FMCW transceiver. In laboratory tests, we verified that the signal processing results from the proposed method were much better than those expected from the conventional 2D FFT-based detection method.

  6. Ground target recognition using rectangle estimation.

    PubMed

    Grönwall, Christina; Gustafsson, Fredrik; Millnert, Mille

    2006-11-01

    We propose a ground target recognition method based on 3-D laser radar data. The method handles general 3-D scattered data. It is based on the fact that man-made objects of complex shape can be decomposed to a set of rectangles. The ground target recognition method consists of four steps; 3-D size and orientation estimation, target segmentation into parts of approximately rectangular shape, identification of segments that represent the target's functional/main parts, and target matching with CAD models. The core in this approach is rectangle estimation. The performance of the rectangle estimation method is evaluated statistically using Monte Carlo simulations. A case study on tank recognition is shown, where 3-D data from four fundamentally different types of laser radar systems are used. Although the approach is tested on rather few examples, we believe that the approach is promising.

  7. Experimental evaluation of the performance of pulsed two-color laser-ranging systems

    NASA Technical Reports Server (NTRS)

    Im, Kwaifong E.; Gardner, Chester S.; Abshire, James B.; Mcgarry, Jan F.

    1987-01-01

    Two-color laser-ranging systems can be used to estimate the atmospheric delay by measuring the difference in propagation times between two optical pulses transmitted at different wavelengths. This paper describes horizontal-path ranging experiments that were conducted using flat diffuse targets and cube-corner reflector arrays. Measurements of the timing accuracy of the cross-correlation estimator, atmospheric delay, received pulse shapes, and signal power spectra are presented. The results are in general agreement with theory and indicate that target speckle can be the dominant noise source when the target is small and is located far from the ranging system or when the target consists of a small number of cube-corner reflectors.

  8. RNA from the 5' end of the R2 retrotransposon controls R2 protein binding to and cleavage of its DNA target site.

    PubMed

    Christensen, Shawn M; Ye, Junqiang; Eickbush, Thomas H

    2006-11-21

    Non-LTR retrotransposons insert into eukaryotic genomes by target-primed reverse transcription (TPRT), a process in which cleaved DNA targets are used to prime reverse transcription of the element's RNA transcript. Many of the steps in the integration pathway of these elements can be characterized in vitro for the R2 element because of the rigid sequence specificity of R2 for both its DNA target and its RNA template. R2 retrotransposition involves identical subunits of the R2 protein bound to different DNA sequences upstream and downstream of the insertion site. The key determinant regulating which DNA-binding conformation the protein adopts was found to be a 320-nt RNA sequence from near the 5' end of the R2 element. In the absence of this 5' RNA the R2 protein binds DNA sequences upstream of the insertion site, cleaves the first DNA strand, and conducts TPRT when RNA containing the 3' untranslated region of the R2 transcript is present. In the presence of the 320-nt 5' RNA, the R2 protein binds DNA sequences downstream of the insertion site. Cleavage of the second DNA strand by the downstream subunit does not appear to occur until after the 5' RNA is removed from this subunit. We postulate that the removal of the 5' RNA normally occurs during reverse transcription, and thus provides a critical temporal link to first- and second-strand DNA cleavage in the R2 retrotransposition reaction.

  9. Discrimination between landmine and mine-like targets using wavelets and spectral analysis

    NASA Astrophysics Data System (ADS)

    Mohana, Mahmoud A.; Abbas, Abbas M.; Gomaa, Mohamed L.; Ebrahim, Shereen M.

    2013-06-01

    Landmine is an explosive apparatus hidden in or on the ground, which blows up when a person or vehicle passes over it. Egypt is one of the countries suffering due to the unexploded ordnance (UXO). Around 2 million UXO are present in the Egyptian soil especially at Al-Alameen province, north of the western desert. Detection of buried landmines is a problem of military and humanitarian importance. Ground penetrating radar (GPR) is a powerful and non-destructive geophysical approach with a wide range of advantages in the field of landmine inspection. In the present paper, we apply different simulation models with Vivaldi antenna and mine-like targets by using the CST Microwave studio program. The field work is carried out by using a GPR device of model SIR 2000 from GSSI (Geophysical Survey Systems Incorporation) connected to 900 MHz antenna where the targets were buried in sand soil. Depending on the fact that the receiving powers (reflected, refracted and scattered) from the different materials are different, we study the spectral power densities for the received power from the different targets. The techniques used in this study are: direct fast Fourier transform, short time Fourier transform (spectrogram), wavelets transform and denoising techniques. Our results ought to be considered as finger prints for different scanned targets during this work. So we can discriminate between landmines and mine-like targets.

  10. Target-present guessing as a function of target prevalence and accumulated information in visual search.

    PubMed

    Peltier, Chad; Becker, Mark W

    2017-05-01

    Target prevalence influences visual search behavior. At low target prevalence, miss rates are high and false alarms are low, while the opposite is true at high prevalence. Several models of search aim to describe search behavior, one of which has been specifically intended to model search at varying prevalence levels. The multiple decision model (Wolfe & Van Wert, Current Biology, 20(2), 121--124, 2010) posits that all searches that end before the observer detects a target result in a target-absent response. However, researchers have found very high false alarms in high-prevalence searches, suggesting that prevalence rates may be used as a source of information to make "educated guesses" after search termination. Here, we further examine the ability for prevalence level and knowledge gained during visual search to influence guessing rates. We manipulate target prevalence and the amount of information that an observer accumulates about a search display prior to making a response to test if these sources of evidence are used to inform target present guess rates. We find that observers use both information about target prevalence rates and information about the proportion of the array inspected prior to making a response allowing them to make an informed and statistically driven guess about the target's presence.

  11. C-Terminal End-Directed Protein Elimination by CRL2 Ubiquitin Ligases.

    PubMed

    Lin, Hsiu-Chuan; Yeh, Chi-Wei; Chen, Yen-Fu; Lee, Ting-Ting; Hsieh, Pei-Yun; Rusnac, Domnita V; Lin, Sung-Ya; Elledge, Stephen J; Zheng, Ning; Yen, Hsueh-Chi S

    2018-05-17

    The proteolysis-assisted protein quality control system guards the proteome from potentially detrimental aberrant proteins. How miscellaneous defective proteins are specifically eliminated and which molecular characteristics direct them for removal are fundamental questions. We reveal a mechanism, DesCEND (destruction via C-end degrons), by which CRL2 ubiquitin ligase uses interchangeable substrate receptors to recognize the unusual C termini of abnormal proteins (i.e., C-end degrons). C-end degrons are mostly less than ten residues in length and comprise a few indispensable residues along with some rather degenerate ones. The C-terminal end position is essential for C-end degron function. Truncated selenoproteins generated by translation errors and the USP1 N-terminal fragment from post-translational cleavage are eliminated by DesCEND. DesCEND also targets full-length proteins with naturally occurring C-end degrons. The C-end degron in DesCEND echoes the N-end degron in the N-end rule pathway, highlighting the dominance of protein "ends" as indicators for protein elimination. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Determination of target detection limits in hyperspectral data using band selection and dimensionality reduction

    NASA Astrophysics Data System (ADS)

    Gross, W.; Boehler, J.; Twizer, K.; Kedem, B.; Lenz, A.; Kneubuehler, M.; Wellig, P.; Oechslin, R.; Schilling, H.; Rotman, S.; Middelmann, W.

    2016-10-01

    Hyperspectral remote sensing data can be used for civil and military applications to robustly detect and classify target objects. High spectral resolution of hyperspectral data can compensate for the comparatively low spatial resolution, which allows for detection and classification of small targets, even below image resolution. Hyperspectral data sets are prone to considerable spectral redundancy, affecting and limiting data processing and algorithm performance. As a consequence, data reduction strategies become increasingly important, especially in view of near-real-time data analysis. The goal of this paper is to analyze different strategies for hyperspectral band selection algorithms and their effect on subpixel classification for different target and background materials. Airborne hyperspectral data is used in combination with linear target simulation procedures to create a representative amount of target-to-background ratios for evaluation of detection limits. Data from two different airborne hyperspectral sensors, AISA Eagle and Hawk, are used to evaluate transferability of band selection when using different sensors. The same target objects were recorded to compare the calculated detection limits. To determine subpixel classification results, pure pixels from the target materials are extracted and used to simulate mixed pixels with selected background materials. Target signatures are linearly combined with different background materials in varying ratios. The commonly used classification algorithms Adaptive Coherence Estimator (ACE) is used to compare the detection limit for the original data with several band selection and data reduction strategies. The evaluation of the classification results is done by assuming a fixed false alarm ratio and calculating the mean target-to-background ratio of correctly detected pixels. The results allow drawing conclusions about specific band combinations for certain target and background combinations. Additionally

  13. Using demography and movement behavior to predict range expansion of the southern sea otter.

    USGS Publications Warehouse

    Tinker, M.T.; Doak, D.F.; Estes, J.A.

    2008-01-01

    In addition to forecasting population growth, basic demographic data combined with movement data provide a means for predicting rates of range expansion. Quantitative models of range expansion have rarely been applied to large vertebrates, although such tools could be useful for restoration and management of many threatened but recovering populations. Using the southern sea otter (Enhydra lutris nereis) as a case study, we utilized integro-difference equations in combination with a stage-structured projection matrix that incorporated spatial variation in dispersal and demography to make forecasts of population recovery and range recolonization. In addition to these basic predictions, we emphasize how to make these modeling predictions useful in a management context through the inclusion of parameter uncertainty and sensitivity analysis. Our models resulted in hind-cast (1989–2003) predictions of net population growth and range expansion that closely matched observed patterns. We next made projections of future range expansion and population growth, incorporating uncertainty in all model parameters, and explored the sensitivity of model predictions to variation in spatially explicit survival and dispersal rates. The predicted rate of southward range expansion (median = 5.2 km/yr) was sensitive to both dispersal and survival rates; elasticity analysis indicated that changes in adult survival would have the greatest potential effect on the rate of range expansion, while perturbation analysis showed that variation in subadult dispersal contributed most to variance in model predictions. Variation in survival and dispersal of females at the south end of the range contributed most of the variance in predicted southward range expansion. Our approach provides guidance for the acquisition of further data and a means of forecasting the consequence of specific management actions. Similar methods could aid in the management of other recovering populations.

  14. Classroom-based and distance learning education and training courses in end-of-life care for health and social care staff: a systematic review.

    PubMed

    Pulsford, David; Jackson, Georgina; O'Brien, Terri; Yates, Sue; Duxbury, Joy

    2013-03-01

    Staff from a range of health and social care professions report deficits in their knowledge and skills when providing end-of-life and palliative care, and education and training has been advocated at a range of levels. To review the literature related to classroom-based and distance learning education and training initiatives for health and social care staff in end-of-life and palliative care, in terms of their target audience, extent, modes of delivery, content and teaching and learning strategies, and to identify the most effective educational strategies for enhancing care. A systematic review of the literature evaluating classroom-based and distance learning education and training courses for health and social care staff in end-of-life and palliative care. Online databases CINAHL, MEDLINE, EMBASE and PSYCHINFO between January 2000 and July 2010. Studies were selected that discussed specific education and training initiatives and included pre-and post-test evaluation of participants' learning. 30 studies met eligibility criteria. The majority reported successful outcomes, though there were some exceptions. Level of prior experience and availability of practice reinforcement influenced learning. Participative and interactive learning strategies were predominantly used along with discussion of case scenarios. Multi-professional learning was infrequently reported and service user and carer input to curriculum development and delivery was reported in only one study. Classroom-based education and training is useful for enhancing professionals' skills and perceived preparedness for delivering end-of-life care but should be reinforced by actual practice experience.

  15. Efficacy for lung metastasis induced by the allogeneic bEnd3 vaccine in mice.

    PubMed

    Zhao, Jun; Lu, Jing; Zhou, Lurong; Zhao, Jimin; Dong, Ziming

    2018-05-04

    The mouse brain microvascular endothelial cell line bEnd.3 was used to develop a vaccine and its anti-tumor effect on lung metastases was observed in immunized mice. Mouse bEnd.3 cells cultured in-vitro and then fixed with glutaraldehyde was used to immunize mice; mice were challenged with the metastatic cancer cell line U14, and changes in metastatic cancer tissues were observed through hematoxylin and eosin staining. Carboxyfluorescein succinimidyl amino ester (CSFE) and propidium iodide (PI) were used to detect cytotoxic activity of spleen T lymphocytes; the ratio of CD3 + and CD8 + T-cell sub-sets was determined by flow cytometry. Enzyme-linked immunosorbent assay (ELISA), immunocytochemistry and immunoblot were used to examine the specific response of the antisera of immunized mice. The number of metastatic nodules in bEnd.3 and human umbilical vein endothelial cell (HUVEC) vaccine groups was less than NIH3T3 vaccine group and phosphate buffered saline (PBS) control group. The bEnd.3-induced and HUVEC-induced cytotoxic T-lymphocytes (CTLs) showed significant lytic activity against bEnd.3 and HUVEC target cells, while the antisera of mice in bEnd.3 and HUVEC vaccine groups showed specific immune responses to membrane proteins and inhibited target cell proliferation in-vitro. Immunoblot results showed specific bands at 180KD and 220KD in bEnd.3 and at 130 kD and 220 kD in HUVEC lysates. Allogeneic bEnd.3 vaccine induced an active and specific immune response to tumor vascular endothelial cells that resulted in production of antibodies against the proliferation antigens VEGF-R II, integrin, Endog etc. Immunization with this vaccine inhibited lung metastasis of cervical cancer U14 cells and prolonged the survival of these mice.

  16. Ultrasonic ranging for the oculometer

    NASA Technical Reports Server (NTRS)

    Guy, W. J.

    1981-01-01

    Ultrasonic tracking techniques are investigated for an oculometer. Two methods are reported in detail. The first is based on measurements of time from the start of a transmit burst to a received echo. Knowing the sound velocity, distance can be calculated. In the second method, a continuous signal is transmitted. Target movement causes phase shifting of the echo. By accumulating these phase shifts, tracking from a set point can be achieved. Both systems have problems with contoured targets, but work well on flat plates and the back of a human head. Also briefly reported is an evaluation of an ultrasonic ranging system. Interface circuits make this system compatible with the echo time design. While the system is consistently accurate, it has a beam too narrow for oculometer use. Finally, comments are provided on a tracking system using the Doppler frequency shift to give range data.

  17. Arcus end-to-end simulations

    NASA Astrophysics Data System (ADS)

    Wilms, Joern; Guenther, H. Moritz; Dauser, Thomas; Huenemoerder, David P.; Ptak, Andrew; Smith, Randall; Arcus Team

    2018-01-01

    We present an overview of the end-to-end simulation environment that we are implementing as part of the Arcus phase A Study. With the rcus simulator, we aim to to model the imaging, detection, and event reconstruction properties of the spectrometer. The simulator uses a Monte Carlo ray-trace approach, projecting photons onto the Arcus focal plane from the silicon pore optic mirrors and critical-angle transmission gratings. We simulate the detection and read-out of the photons in the focal plane CCDs with software originally written for the eROSITA and Athena-WFI detectors; we include all relevant detector physics, such as charge splitting, and effects of the detector read-out, such as out of time events. The output of the simulation chain is an event list that closely resembles the data expected during flight. This event list is processed using a prototype event reconstruction chain for the order separation, wavelength calibration, and effective area calibration. The output is compatible with standard X-ray astronomical analysis software.During phase A, the end-to-end simulation approach is used to demonstrate the overall performance of the mission, including a full simulation of the calibration effort. Continued development during later phases of the mission will ensure that the simulator remains a faithful representation of the true mission capabilities, and will ultimately be used as the Arcus calibration model.

  18. SU-F-J-177: A Novel Image Analysis Technique (center Pixel Method) to Quantify End-To-End Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wen, N; Chetty, I; Snyder, K

    Purpose: To implement a novel image analysis technique, “center pixel method”, to quantify end-to-end tests accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy was determined by delivering radiation to an end-to-end prototype phantom. The phantom was scanned with 0.8 mm slice thickness. The treatment isocenter was placed at the center of the phantom. In the treatment room, CBCT images of the phantom (kVp=77, mAs=1022, slice thickness 1 mm) were acquired to register to the reference CT images. 6D couch correction were applied based on the registration results. Electronic Portal Imaging Device (EPID)-based Winston Lutz (WL)more » tests were performed to quantify the errors of the targeting accuracy of the system at 15 combinations of gantry, collimator and couch positions. The images were analyzed using two different methods. a) The classic method. The deviation was calculated by measuring the radial distance between the center of the central BB and the full width at half maximum of the radiation field. b) The center pixel method. Since the imager projection offset from the treatment isocenter was known from the IsoCal calibration, the deviation was determined between the center of the BB and the central pixel of the imager panel. Results: Using the automatic registration method to localize the phantom and the classic method of measuring the deviation of the BB center, the mean and standard deviation of the radial distance was 0.44 ± 0.25, 0.47 ± 0.26, and 0.43 ± 0.13 mm for the jaw, MLC and cone defined field sizes respectively. When the center pixel method was used, the mean and standard deviation was 0.32 ± 0.18, 0.32 ± 0.17, and 0.32 ± 0.19 mm respectively. Conclusion: Our results demonstrated that the center pixel method accurately analyzes the WL images to evaluate the targeting accuracy of the radiosurgery system. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the

  19. Range detection using entangled optical photons

    NASA Astrophysics Data System (ADS)

    Brandsema, Matthew J.; Narayanan, Ram M.; Lanzagorta, Marco

    2015-05-01

    Quantum radar is an emerging field that shows a lot of promise in providing significantly improved resolution compared to its classical radar counterpart. The key to this kind of resolution lies in the correlations created from the entanglement of the photons being used. Currently, the technology available only supports quantum radar implementation and validation in the optical regime, as opposed to the microwave regime, because microwave photons have very low energy compared to optical photons. Furthermore, there currently do not exist practical single photon detectors and generators in the microwave spectrum. Viable applications in the optical regime include deep sea target detection and high resolution detection in space. In this paper, we propose a conceptual architecture of a quantum radar which uses entangled optical photons based on Spontaneous Parametric Down Conversion (SPDC) methods. After the entangled photons are created and emerge from the crystal, the idler photon is detected very shortly thereafter. At the same time, the signal photon is sent out towards the target and upon its reflection will impinge on the detector of the radar. From these two measurements, correlation data processing is done to obtain the distance of the target away from the radar. Various simulations are then shown to display the resolution that is possible.

  20. End-to-end security for personal telehealth.

    PubMed

    Koster, Paul; Asim, Muhammad; Petkovic, Milan

    2011-01-01

    Personal telehealth is in rapid development with innovative emerging applications like disease management. With personal telehealth people participate in their own care supported by an open distributed system with health services. This poses new end-to-end security and privacy challenges. In this paper we introduce new end-to-end security requirements and present a design for consent management in the context of the Continua Health Alliance architecture. Thus, we empower patients to control how their health information is shared and used in a personal telehealth eco-system.

  1. Advanced integrated safeguards using front-end-triggering devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howell, J.A.; Whitty, W.J.

    This report addresses potential uses of front-end-triggering devices for enhanced safeguards. Such systems incorporate video surveillance as well as radiation and other sensors. Also covered in the report are integration issues and analysis techniques.

  2. WE-DE-BRA-11: A Study of Motion Tracking Accuracy of Robotic Radiosurgery Using a Novel CCD Camera Based End-To-End Test System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, L; M Yang, Y; Nelson, B

    Purpose: A novel end-to-end test system using a CCD camera and a scintillator based phantom (XRV-124, Logos Systems Int’l) capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery (CyberKnife) was developed and reported in our previous work. This work investigates its application in assessing the motion tracking (Synchrony) accuracy for CyberKnife. Methods: A QA plan with Anterior and Lateral beams (with 4 different collimator sizes) was created (Multiplan v5.3) for the XRV-124 phantom. The phantom was placed on a motion platform (superior and inferior movement), and the plans were delivered on the CyberKnife M6 system using four motion patterns:more » static, Sine- wave, Sine with 15° phase shift, and a patient breathing pattern composed of 2cm maximum motion with 4 second breathing cycle. Under integral recording mode, the time-averaged beam vectors (X, Y, Z) were measured by the phantom and compared with static delivery. In dynamic recording mode, the beam spots were recorded at a rate of 10 frames/second. The beam vector deviation from average position was evaluated against the various breathing patterns. Results: The average beam position of the six deliveries with no motion and three deliveries with Synchrony tracking on ideal motion (sinewave without phase shift) all agree within −0.03±0.00 mm, 0.10±0.04, and 0.04±0.03 in the X, Y, and X directions. Radiation beam width (FWHM) variations are within ±0.03 mm. Dynamic video record showed submillimeter tracking stability for both regular and irregular breathing pattern; however the tracking error up to 3.5 mm was observed when a 15 degree phase shift was introduced. Conclusion: The XRV-124 system is able to provide 3D and 4D targeting accuracy for CyberKnife delivery with Synchrony. The experimental results showed sub-millimeter delivery in phantom with excellent correlation in target to breathing motion. The accuracy was degraded when irregular motion and phase shift was

  3. Saccadic foveation of a moving visual target in the rhesus monkey.

    PubMed

    Fleuriet, Jérome; Hugues, Sandrine; Perrinet, Laurent; Goffart, Laurent

    2011-02-01

    When generating a saccade toward a moving target, the target displacement that occurs during the period spanning from its detection to the saccade end must be taken into account to accurately foveate the target and to initiate its pursuit. Previous studies have shown that these saccades are characterized by a lower peak velocity and a prolonged deceleration phase. In some cases, a second peak eye velocity appears during the deceleration phase, presumably reflecting the late influence of a mechanism that compensates for the target displacement occurring before saccade end. The goal of this work was to further determine in the head restrained monkey the dynamics of this putative compensatory mechanism. A step-ramp paradigm, where the target motion was orthogonal to a target step occurring along the primary axes, was used to estimate from the generated saccades: a component induced by the target step and another one induced by the target motion. Resulting oblique saccades were compared with saccades to a static target with matched horizontal and vertical amplitudes. This study permitted to estimate the time taken for visual motion-related signals to update the programming and execution of saccades. The amplitude of the motion-related component was slightly hypometric with an undershoot that increased with target speed. Moreover, it matched with the eccentricity that the target had 40-60 ms before saccade end. The lack of significant difference in the delay between the onsets of the horizontal and vertical components between saccades directed toward a static target and those aimed at a moving target questions the late influence of the compensatory mechanism. The results are discussed within the framework of the "dual drive" and "remapping" hypotheses.

  4. 46th Annual Targets, UAVs and Range Operations Symposium and Exhibition

    DTIC Science & Technology

    2008-10-10

    introduction  mr. Ken Hislop , QF-16 Program manager, eglin aFB, FL 1:40 Pm - 2:00 Pm U.s. navy  CaPt Pat Buckley, Usn, Program manager...Bruce Ringstad Subscale & TCS Flight Lead Mr. Jim Cornwell Program Manager Mr. Ken Hislop Program Manager Ms. Lee Neugin Program Manager & Lead...Missiles Fired / 18 Kills AAC/PA 09-26-08-429 18 QF-16 Air Superiority Target Program Manager: Mr. Ken Hislop Description Full Scale Target for Threat

  5. Faster diffraction-based overlay measurements with smaller targets using 3D gratings

    NASA Astrophysics Data System (ADS)

    Li, Jie; Kritsun, Oleg; Liu, Yongdong; Dasari, Prasad; Volkman, Catherine; Hu, Jiangtao

    2012-03-01

    Diffraction-based overlay (DBO) technologies have been developed to address the overlay metrology challenges for 22nm technology node and beyond. Most DBO technologies require specially designed targets that consist of multiple measurement pads, which consume too much space and increase measurement time. The traditional empirical approach (eDBO) using normal incidence spectroscopic reflectometry (NISR) relies on linear response of the reflectance with respect to overlay displacement within a small range. It offers convenience of quick recipe setup since there is no need to establish a model. However it requires three or four pads per direction (x or y) which adds burden to throughput and target size. Recent advances in modeling capability and computation power enabled mDBO, which allows overlay measurement with reduced number of pads, thus reducing measurement time and DBO target space. In this paper we evaluate the performance of single pad mDBO measurements using two 3D targets that have different grating shapes: squares in boxes and L-shapes in boxes. Good overlay sensitivities are observed for both targets. The correlation to programmed shifts and image-based overlay (IBO) is excellent. Despite the difference in shapes, the mDBO results are comparable for square and L-shape targets. The impact of process variations on overlay measurements is studied using a focus and exposure matrix (FEM) wafer. Although the FEM wafer has larger process variations, the correlation of mDBO results with IBO measurements is as good as the normal process wafer. We demonstrate the feasibility of single pad DBO measurements with faster throughput and smaller target size, which is particularly important in high volume manufacturing environment.

  6. Pion Production from 5-15 GeV Beam for the Neutrino Factory Front-End Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prior, Gersende

    2010-03-30

    For the neutrino factory front-end study, the production of pions from a proton beam of 5-8 and 14 GeV kinetic energy on a Hg jet target has been simulated. The pion yields for two versions of the MARS15 code and two different field configurations have been compared. The particles have also been tracked from the target position down to the end of the cooling channel using the ICOOL code and the neutrino factory baseline lattice. The momentum-angle region of pions producing muons that survived until the end of the cooling channel has been compared with the region covered by HARPmore » data and the number of pions/muons as a function of the incoming beam energy is also reported.« less

  7. A high yield neutron target

    NASA Technical Reports Server (NTRS)

    Alger, D. L.; Steinberg, R.; Weisenbach, P.

    1974-01-01

    Target, in cylinder form, rotates rapidly in front of beam. Titanium tritide film is much thicker than range of accelerated deutron. Sputtering electrode permits full use of thick film. Stream of high-velocity coolant provides efficient transfer of heat from target.

  8. A Comparison of Herpetofaunal Sampling Effectiveness of Pitfall, Single-ended, and Double-ended Funnel Traps Used with Drift Fences

    Treesearch

    Cathryn H. Greenberg; Daniel G. Neary; Larry D. Harris

    1994-01-01

    We assessed the relative effectiveness of pitfalls, single-ended, and double-ended funnel traps at 12 replicate sites in sand pine scrub using drift fence arrays. Pitfalls captured fewer species but yielded more individuals of many species and higher average species richness than funnel traps. Pitfalls and funnel traps exhibited differential capture bias probably due...

  9. Bistatic image processing for a 32 x 19 inch model aircraft using scattered fields obtained in the OSU-ESL compact range

    NASA Technical Reports Server (NTRS)

    Lee, T-H.; Burnside, W. D.

    1992-01-01

    Inverse Synthetic Aperture Radar (ISAR) images for a 32 in long and 19 in wide model aircraft are documented. Both backscattered and bistatic scattered fields of this model aircraft were measured in the OSU-ESL compact range to obtain these images. The scattered fields of the target were measured for frequencies from 2 to 18 GHz with a 10 MHz increment and for full 360 deg azimuth rotation angles with a 0.2 deg step. For the bistatic scattering measurement, the compact range was used as the transmitting antenna; while, a broad band AEL double ridge horn was used as the receiving antenna. Bistatic angles of 90 deg and 135 deg were measured. Due to the size of the chamber and target, the receiving antenna was in the near field of the target; nevertheless, the image processing algorithm was valid for this case.

  10. Shape optimization of electrostatically driven microcantilevers using simulated annealing to enhance static travel range

    NASA Astrophysics Data System (ADS)

    Trivedi, R. R.; Joglekar, M. M.; Shimpi, R. P.; Pawaskar, D. N.

    2013-12-01

    The objective of this paper is to present a systematic development of the generic shape optimization of elec- trostatically actuated microcantilever beams for extending their static travel range. Electrostatic actuators are widely used in micro electro mechanical system (MEMS) devices because of low power density and ease of fab- rication. However, their useful travel range is often restricted by a phenomenon known as pull-in instability. The Rayleigh- Ritz energy method is used for computation of pull-in parameters which includes electrostatic potential and fringing field effect. Appropriate width function and linear thickness functions are employed along the length of the non-prismatic beam to achieve enhanced travel range. Parameters used for varying the thick- ness and width functions are optimized using simulated annealing with pattern search method towards the end to refine the results. Appropriate penalties are imposed on the violation of volume, width, thickness and area constraints. Nine test cases are considered for demonstration of the said optimization method. Our results indicate that around 26% increase in the travel range of a non-prismatic beam can be achieved after optimiza- tion compared to that in a prismatic beam having the same volume. Our results also show an improvement in the pull-in displacement of around 5% compared to that of a variable width constant thickness actuator. We show that simulated annealing is an effective and flexible method to carry out design optimization of structural elements under electrostatic loading.

  11. The target plant concept-a history and brief overview

    Treesearch

    Thomas D. Landis

    2011-01-01

    The target plant concept originated with morphological classification of conifer nursery stock in the 1930s, and the concept was enhanced through physiological research and seedling testing towards the end of the century. Morphological grading standards such as shoot height, stem diameter, and root mass are the most common use of the target plant concept, and some...

  12. In vitro Selection and Interaction Studies of a DNA Aptamer Targeting Protein A

    PubMed Central

    Stoltenburg, Regina; Schubert, Thomas; Strehlitz, Beate

    2015-01-01

    A new DNA aptamer targeting Protein A is presented. The aptamer was selected by use of the FluMag-SELEX procedure. The SELEX technology (Systematic Evolution of Ligands by EXponential enrichment) is widely applied as an in vitro selection and amplification method to generate target-specific aptamers and exists in various modified variants. FluMag-SELEX is one of them and is characterized by the use of magnetic beads for target immobilization and fluorescently labeled oligonucleotides for monitoring the aptamer selection progress. Structural investigations and sequence truncation experiments of the selected aptamer for Protein A led to the conclusion, that a stem-loop structure at its 5’-end including the 5’-primer binding site is essential for aptamer-target binding. Extensive interaction analyses between aptamer and Protein A were performed by methods like surface plasmon resonance, MicroScale Thermophoresis and bead-based binding assays using fluorescence measurements. The binding of the aptamer to its target was thus investigated in assays with immobilization of one of the binding partners each, and with both binding partners in solution. Affinity constants were determined in the low micromolar to submicromolar range, increasing to the nanomolar range under the assumption of avidity. Protein A provides more than one binding site for the aptamer, which may overlap with the known binding sites for immunoglobulins. The aptamer binds specifically to both native and recombinant Protein A, but not to other immunoglobulin-binding proteins like Protein G and L. Cross specificity to other proteins was not found. The application of the aptamer is directed to Protein A detection or affinity purification. Moreover, whole cells of Staphylococcus aureus, presenting Protein A on the cell surface, could also be bound by the aptamer. PMID:26221730

  13. In vitro Selection and Interaction Studies of a DNA Aptamer Targeting Protein A.

    PubMed

    Stoltenburg, Regina; Schubert, Thomas; Strehlitz, Beate

    2015-01-01

    A new DNA aptamer targeting Protein A is presented. The aptamer was selected by use of the FluMag-SELEX procedure. The SELEX technology (Systematic Evolution of Ligands by EXponential enrichment) is widely applied as an in vitro selection and amplification method to generate target-specific aptamers and exists in various modified variants. FluMag-SELEX is one of them and is characterized by the use of magnetic beads for target immobilization and fluorescently labeled oligonucleotides for monitoring the aptamer selection progress. Structural investigations and sequence truncation experiments of the selected aptamer for Protein A led to the conclusion, that a stem-loop structure at its 5'-end including the 5'-primer binding site is essential for aptamer-target binding. Extensive interaction analyses between aptamer and Protein A were performed by methods like surface plasmon resonance, MicroScale Thermophoresis and bead-based binding assays using fluorescence measurements. The binding of the aptamer to its target was thus investigated in assays with immobilization of one of the binding partners each, and with both binding partners in solution. Affinity constants were determined in the low micromolar to submicromolar range, increasing to the nanomolar range under the assumption of avidity. Protein A provides more than one binding site for the aptamer, which may overlap with the known binding sites for immunoglobulins. The aptamer binds specifically to both native and recombinant Protein A, but not to other immunoglobulin-binding proteins like Protein G and L. Cross specificity to other proteins was not found. The application of the aptamer is directed to Protein A detection or affinity purification. Moreover, whole cells of Staphylococcus aureus, presenting Protein A on the cell surface, could also be bound by the aptamer.

  14. Accuracy and repeatability of long-bone replicas of small animals fabricated by use of low-end and high-end commercial three-dimensional printers.

    PubMed

    Cone, Jamie A; Martin, Thomas M; Marcellin-Little, Denis J; Harrysson, Ola L A; Griffith, Emily H

    2017-08-01

    OBJECTIVE To assess the repeatability and accuracy of polymer replicas of small, medium, and large long bones of small animals fabricated by use of 2 low-end and 2 high-end 3-D printers. SAMPLE Polymer replicas of a cat femur, dog radius, and dog tibia were fabricated in triplicate by use of each of four 3-D printing methods. PROCEDURES 3-D renderings of the 3 bones reconstructed from CT images were prepared, and length, width of the proximal aspect, and width of the distal aspect of each CT image were measured in triplicate. Polymer replicas were fabricated by use of a high-end system that relied on jetting of curable liquid photopolymer, a high-end system that relied on polymer extrusion, a triple-nozzle polymer extrusion low-end system, and a dual-nozzle polymer extrusion low-end system. Polymer replicas were scanned by use of a laser-based coordinate measurement machine. Length, width of the proximal aspect, and width of the distal aspect of the scans of replicas were measured and compared with measurements for the 3-D renderings. RESULTS 129 measurements were collected for 34 replicas (fabrication of 1 large long-bone replica was unsuccessful on each of the 2 low-end printers). Replicas were highly repeatable for all 3-D printers. The 3-D printers overestimated dimensions of large replicas by approximately 1%. CONCLUSIONS AND CLINICAL RELEVANCE Low-end and high-end 3-D printers fabricated CT-derived replicas of bones of small animals with high repeatability. Replicas were slightly larger than the original bones.

  15. Diagnosing Students’ conception on atomic structure using open ended questions

    NASA Astrophysics Data System (ADS)

    Fitriza, Z.; Gazali, F.

    2018-05-01

    This study aims to diagnose students’ conception on atomic structure concepts using open ended questions. For this reason, a 7 items of assay test was administered to 135 senior high school students from different schools in West Sumatera. The data were collected using a an open ended test which is covering the concept used in the topic Atomic Structure. The open ended test of students’ conceptual was developed to identify the alternative conceptions that student might have regarding the concepts in Atomic Structure, to measure the level of students’ conceptions, and the way of students’ thinking concerning the concepts. The results showed that students find difficulties about some concepts of Atomic structure such as atom, atomic model, electron configuration, period and group.The result of this study illuminated the concepts to be underlined in developing teaching and learning approach concerning the topic of Atomic Structure.

  16. Modelling PET radionuclide production in tissue and external targets using Geant4

    NASA Astrophysics Data System (ADS)

    Amin, T.; Infantino, A.; Lindsay, C.; Barlow, R.; Hoehr, C.

    2017-07-01

    The Proton Therapy Facility in TRIUMF provides 74 MeV protons extracted from a 500 MeV H- cyclotron for ocular melanoma treatments. During treatment, positron emitting radionuclides such as 1C, 15O and 13N are produced in patient tissue. Using PET scanners, the isotopic activity distribution can be measured for in-vivo range verification. A second cyclotron, the TR13, provides 13 MeV protons onto liquid targets for the production of PET radionuclides such as 18F, 13N or 68Ga, for medical applications. The aim of this work was to validate Geant4 against FLUKA and experimental measurements for production of the above-mentioned isotopes using the two cyclotrons. The results show variable degrees of agreement. For proton therapy, the proton-range agreement was within 2 mm for 11C activity, whereas 13N disagreed. For liquid targets at the TR13 the average absolute deviation ratio between FLUKA and experiment was 1.9±2.7, whereas the average absolute deviation ratio between Geant4 and experiment was 0. 6±0.4. This is due to the uncertainties present in experimentally determined reaction cross sections.

  17. Tool Condition Monitoring in Micro-End Milling using wavelets

    NASA Astrophysics Data System (ADS)

    Dubey, N. K.; Roushan, A.; Rao, U. S.; Sandeep, K.; Patra, K.

    2018-04-01

    In this work, Tool Condition Monitoring (TCM) strategy is developed for micro-end milling of titanium alloy and mild steel work-pieces. Full immersion slot milling experiments are conducted using a solid tungsten carbide end mill for more than 1900 s to have reasonable amount of tool wear. During the micro-end milling process, cutting force and vibration signals are acquired using Kistler piezo-electric 3-component force dynamometer (9256C2) and accelerometer (NI cDAQ-9188) respectively. The force components and the vibration signals are processed using Discrete Wavelet Transformation (DWT) in both time and frequency window. 5-level wavelet packet decomposition using Db-8 wavelet is carried out and the detailed coefficients D1 to D5 for each of the signals are obtained. The results of the wavelet transformation are correlated with the tool wear. In case of vibration signals, de-noising is done for higher frequency components (D1) and force signals were de-noised for lower frequency components (D5). Increasing value of MAD (Mean Absolute Deviation) of the detail coefficients for successive channels depicted tool wear. The predictions of the tool wear are confirmed from the actual wear observed in the SEM of the worn tool.

  18. Robust Ground Target Detection by SAR and IR Sensor Fusion Using Adaboost-Based Feature Selection

    PubMed Central

    Kim, Sungho; Song, Woo-Jin; Kim, So-Hyun

    2016-01-01

    Long-range ground targets are difficult to detect in a noisy cluttered environment using either synthetic aperture radar (SAR) images or infrared (IR) images. SAR-based detectors can provide a high detection rate with a high false alarm rate to background scatter noise. IR-based approaches can detect hot targets but are affected strongly by the weather conditions. This paper proposes a novel target detection method by decision-level SAR and IR fusion using an Adaboost-based machine learning scheme to achieve a high detection rate and low false alarm rate. The proposed method consists of individual detection, registration, and fusion architecture. This paper presents a single framework of a SAR and IR target detection method using modified Boolean map visual theory (modBMVT) and feature-selection based fusion. Previous methods applied different algorithms to detect SAR and IR targets because of the different physical image characteristics. One method that is optimized for IR target detection produces unsuccessful results in SAR target detection. This study examined the image characteristics and proposed a unified SAR and IR target detection method by inserting a median local average filter (MLAF, pre-filter) and an asymmetric morphological closing filter (AMCF, post-filter) into the BMVT. The original BMVT was optimized to detect small infrared targets. The proposed modBMVT can remove the thermal and scatter noise by the MLAF and detect extended targets by attaching the AMCF after the BMVT. Heterogeneous SAR and IR images were registered automatically using the proposed RANdom SAmple Region Consensus (RANSARC)-based homography optimization after a brute-force correspondence search using the detected target centers and regions. The final targets were detected by feature-selection based sensor fusion using Adaboost. The proposed method showed good SAR and IR target detection performance through feature selection-based decision fusion on a synthetic database generated

  19. Robust Ground Target Detection by SAR and IR Sensor Fusion Using Adaboost-Based Feature Selection.

    PubMed

    Kim, Sungho; Song, Woo-Jin; Kim, So-Hyun

    2016-07-19

    Long-range ground targets are difficult to detect in a noisy cluttered environment using either synthetic aperture radar (SAR) images or infrared (IR) images. SAR-based detectors can provide a high detection rate with a high false alarm rate to background scatter noise. IR-based approaches can detect hot targets but are affected strongly by the weather conditions. This paper proposes a novel target detection method by decision-level SAR and IR fusion using an Adaboost-based machine learning scheme to achieve a high detection rate and low false alarm rate. The proposed method consists of individual detection, registration, and fusion architecture. This paper presents a single framework of a SAR and IR target detection method using modified Boolean map visual theory (modBMVT) and feature-selection based fusion. Previous methods applied different algorithms to detect SAR and IR targets because of the different physical image characteristics. One method that is optimized for IR target detection produces unsuccessful results in SAR target detection. This study examined the image characteristics and proposed a unified SAR and IR target detection method by inserting a median local average filter (MLAF, pre-filter) and an asymmetric morphological closing filter (AMCF, post-filter) into the BMVT. The original BMVT was optimized to detect small infrared targets. The proposed modBMVT can remove the thermal and scatter noise by the MLAF and detect extended targets by attaching the AMCF after the BMVT. Heterogeneous SAR and IR images were registered automatically using the proposed RANdom SAmple Region Consensus (RANSARC)-based homography optimization after a brute-force correspondence search using the detected target centers and regions. The final targets were detected by feature-selection based sensor fusion using Adaboost. The proposed method showed good SAR and IR target detection performance through feature selection-based decision fusion on a synthetic database generated

  20. Start-Stop Moment Optimization of Range Extender and Control Strategy Design for Extended -Range Electric Vehicle

    NASA Astrophysics Data System (ADS)

    Zhao, Jing-bo; Han, Bing-yuan; Bei, Shao-yi

    2017-10-01

    Range extender is the core component of E-REV, its start-stop control determines the operation modes of vehicle. This paper based on a certain type of E-REV, researched constant power control strategy of range extender in extended-range model, to target range as constraint condition, combined with different driving cycle conditions, by correcting battery SOC for range extender start-stop moment, optimized the control strategy of range extender, and established the vehicle and range extender start-stop control simulation model. Selected NEDC and UDDS conditions simulation results show that: under certain target mileage, the range extender running time reduced by 37.2% and 28.2% in the NEDC condition, and running time UDDS conditions were reduced by 40.6% and 33.5% in the UDDS condition, reached the purpose of meeting the vehicle mileage and reducing consumption and emission.

  1. Use of laser range finders and range image analysis in automated assembly tasks

    NASA Technical Reports Server (NTRS)

    Alvertos, Nicolas; Dcunha, Ivan

    1990-01-01

    A proposition to study the effect of filtering processes on range images and to evaluate the performance of two different laser range mappers is made. Median filtering was utilized to remove noise from the range images. First and second order derivatives are then utilized to locate the similarities and dissimilarities between the processed and the original images. Range depth information is converted into spatial coordinates, and a set of coefficients which describe 3-D objects is generated using the algorithm developed in the second phase of this research. Range images of spheres and cylinders are used for experimental purposes. An algorithm was developed to compare the performance of two different laser range mappers based upon the range depth information of surfaces generated by each of the mappers. Furthermore, an approach based on 2-D analytic geometry is also proposed which serves as a basis for the recognition of regular 3-D geometric objects.

  2. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

    NASA Astrophysics Data System (ADS)

    Bowen, S. R.; Nyflot, M. J.; Herrmann, C.; Groh, C. M.; Meyer, J.; Wollenweber, S. D.; Stearns, C. W.; Kinahan, P. E.; Sandison, G. A.

    2015-05-01

    Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [18F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT

  3. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study.

    PubMed

    Bowen, S R; Nyflot, M J; Herrmann, C; Groh, C M; Meyer, J; Wollenweber, S D; Stearns, C W; Kinahan, P E; Sandison, G A

    2015-05-07

    Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [(18)F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and

  4. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

    PubMed Central

    Bowen, S R; Nyflot, M J; Hermann, C; Groh, C; Meyer, J; Wollenweber, S D; Stearns, C W; Kinahan, P E; Sandison, G A

    2015-01-01

    Effective positron emission tomography/computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [18F]FDG. The lung lesion insert was driven by 6 different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy (VMAT) were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses (EUD), and 2%-2mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10–20%, treatment planning errors were 5–10%, and treatment delivery errors were 5–30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5–10% in PET/CT imaging, < 5% in treatment planning, and < 2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT

  5. Range gated strip proximity sensor

    DOEpatents

    McEwan, T.E.

    1996-12-03

    A range gated strip proximity sensor uses one set of sensor electronics and a distributed antenna or strip which extends along the perimeter to be sensed. A micro-power RF transmitter is coupled to the first end of the strip and transmits a sequence of RF pulses on the strip to produce a sensor field along the strip. A receiver is coupled to the second end of the strip, and generates a field reference signal in response to the sequence of pulse on the line combined with received electromagnetic energy from reflections in the field. The sensor signals comprise pulses of radio frequency signals having a duration of less than 10 nanoseconds, and a pulse repetition rate on the order of 1 to 10 MegaHertz or less. The duration of the radio frequency pulses is adjusted to control the range of the sensor. An RF detector feeds a filter capacitor in response to received pulses on the strip line to produce a field reference signal representing the average amplitude of the received pulses. When a received pulse is mixed with a received echo, the mixing causes a fluctuation in the amplitude of the field reference signal, providing a range-limited Doppler type signature of a field disturbance. 6 figs.

  6. Range gated strip proximity sensor

    DOEpatents

    McEwan, Thomas E.

    1996-01-01

    A range gated strip proximity sensor uses one set of sensor electronics and a distributed antenna or strip which extends along the perimeter to be sensed. A micro-power RF transmitter is coupled to the first end of the strip and transmits a sequence of RF pulses on the strip to produce a sensor field along the strip. A receiver is coupled to the second end of the strip, and generates a field reference signal in response to the sequence of pulse on the line combined with received electromagnetic energy from reflections in the field. The sensor signals comprise pulses of radio frequency signals having a duration of less than 10 nanoseconds, and a pulse repetition rate on the order of 1 to 10 MegaHertz or less. The duration of the radio frequency pulses is adjusted to control the range of the sensor. An RF detector feeds a filter capacitor in response to received pulses on the strip line to produce a field reference signal representing the average amplitude of the received pulses. When a received pulse is mixed with a received echo, the mixing causes a fluctuation in the amplitude of the field reference signal, providing a range-limited Doppler type signature of a field disturbance.

  7. Facility Targeting, Protection and Mission Decision Making Using the VISAC Code

    NASA Technical Reports Server (NTRS)

    Morris, Robert H.; Sulfredge, C. David

    2011-01-01

    The Visual Interactive Site Analysis Code (VISAC) has been used by DTRA and several other agencies to aid in targeting facilities and to predict the associated collateral effects for the go, no go mission decision making process. VISAC integrates the three concepts of target geometric modeling, damage assessment capabilities, and an event/fault tree methodology for evaluating accident/incident consequences. It can analyze a variety of accidents/incidents at nuclear or industrial facilities, ranging from simple component sabotage to an attack with military or terrorist weapons. For nuclear facilities, VISAC predicts the facility damage, estimated downtime, amount and timing of any radionuclides released. Used in conjunction with DTRA's HPAC code, VISAC also can analyze transport and dispersion of the radionuclides, levels of contamination of the surrounding area, and the population at risk. VISAC has also been used by the NRC to aid in the development of protective measures for nuclear facilities that may be subjected to attacks by car/truck bombs.

  8. Moving target parameter estimation of SAR after two looks cancellation

    NASA Astrophysics Data System (ADS)

    Gan, Rongbing; Wang, Jianguo; Gao, Xiang

    2005-11-01

    Moving target detection of synthetic aperture radar (SAR) by two looks cancellation is studied. First, two looks are got by the first and second half of the synthetic aperture. After two looks cancellation, the moving targets are reserved and stationary targets are removed. After that, a Constant False Alarm Rate (CFAR) detector detects moving targets. The ground range velocity and cross-range velocity of moving target can be got by the position shift between the two looks. We developed a method to estimate the cross-range shift due to slant range moving. we estimate cross-range shift by Doppler frequency center. Wigner-Ville Distribution (WVD) is used to estimate the Doppler frequency center (DFC). Because the range position and cross range before correction is known, estimation of DFC is much easier and efficient. Finally experiments results show that our algorithms have good performance. With the algorithms we can estimate the moving target parameter accurately.

  9. High dynamic range subjective testing

    NASA Astrophysics Data System (ADS)

    Allan, Brahim; Nilsson, Mike

    2016-09-01

    This paper describes of a set of subjective tests that the authors have carried out to assess the end user perception of video encoded with High Dynamic Range technology when viewed in a typical home environment. Viewers scored individual single clips of content, presented in High Definition (HD) and Ultra High Definition (UHD), in Standard Dynamic Range (SDR), and in High Dynamic Range (HDR) using both the Perceptual Quantizer (PQ) and Hybrid Log Gamma (HLG) transfer characteristics, and presented in SDR as the backwards compatible rendering of the HLG representation. The quality of SDR HD was improved by approximately equal amounts by either increasing the dynamic range or increasing the resolution to UHD. A further smaller increase in quality was observed in the Mean Opinion Scores of the viewers by increasing both the dynamic range and the resolution, but this was not quite statistically significant.

  10. Neuroma prevention by end-to-side neurorraphy: an experimental study in rats.

    PubMed

    Aszmann, Oskar C; Korak, Klaus J; Rab, Matthias; Grünbeck, Matthias; Lassmann, Hans; Frey, Manfred

    2003-11-01

    The successful treatment of painful neuromas remains a difficult goal to attain. In this report we explore the feasibility of neuroma prevention by insertion of the proximal end of a nerve through an end-to-side neurorraphy into an adjacent mixed nerve to provide a pathway and target for axons deprived of their end organ. Experiments were performed on a total of twenty 250-g Sprague-Dawley rats. Two groups of 10 animals were prepared. Group A served as an anatomic control. In group B the right saphenous nerve was transected and implanted end-to-side through an epineurial window into the tibial nerve distal to the trifurcation of the sciatic nerve. After 12 weeks the corresponding sensory neurons were identified by retrograde labeling techniques and histomorphometric analysis of the proximal and distal tibial nerve segments, and regular histology of the end-to-side site were performed. The results of the retrograde labeling of the corresponding sensory neuron pool of the saphenus nerve showed extensive labelling of the L1 to L3 spinal ganglions after intracutaneous tracer application of the planta pedis. The morphology of the end-to-side coaptation site and histomorphologic analysis prove that sensory neurons penetrate the perineurial sheath and axons regenerate along the tibial Schwann cell tubes toward their targets. Axons of a severed peripheral nerve that are provided with a pathway and target through an end-to-side coaptation will either be pruned or establish some type of end-organ contact so that a neuroma can be prevented. Whether these axons will lead to disturbing sensations such as paresthesia or dysesthesia in the newly found environment or remain silent codwellers, this experiment cannot answer. Long-term results of future clinical work will have to decide whether the prevention of the neuroma through end-to-side coaptation will be an appropriate therapy for this difficult problem.

  11. Theory of end-labeled free-solution electrophoresis: is the end effect important?

    PubMed

    Chubynsky, Mykyta V; Slater, Gary W

    2014-03-01

    In the theory of free-solution electrophoresis of a polyelectrolyte (such as the DNA) conjugated with a "drag-tag," the conjugate is divided into segments of equal hydrodynamic friction and its electrophoretic mobility is calculated as a weighted average of the mobilities of individual segments. If all the weights are assumed equal, then for an electrically neutral drag-tag, the elution time t is predicted to depend linearly on the inverse DNA length 1/M. While it is well-known that the equal-weights assumption is approximate and in reality the weights increase toward the ends, this "end effect" has been assumed to be small, since in experiments the t(1/M) dependence seems to be nearly perfectly linear. We challenge this assumption pointing out that some experimental linear fits do not extrapolate to the free (i.e. untagged) DNA elution time in the limit 1/M→0, indicating nonlinearity outside the fitting range. We show that a theory for a flexible polymer taking the end effect into account produces a nonlinear curve that, however, can be fitted with a straight line over a limited range of 1/M typical of experiments, but with a "wrong" intercept, which explains the experimental results without additional assumptions. We also study the influence of the flexibilities of the charged and neutral parts. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Range Imaging without Moving Parts

    NASA Technical Reports Server (NTRS)

    Blair, J. Bryan; Scott, V. Stanley, III; Ramos-Izquierdo, Luis

    2008-01-01

    Range-imaging instruments of a type now under development are intended to generate the equivalent of three-dimensional images from measurements of the round-trip times of flight of laser pulses along known directions. These instruments could also provide information on characteristics of targets, including roughnesses and reflectivities of surfaces and optical densities of such semi-solid objects as trees and clouds. Unlike in prior range-imaging instruments based on times of flight along known directions, there would be no moving parts; aiming of the laser beams along the known directions would not be accomplished by mechanical scanning of mirrors, prisms, or other optical components. Instead, aiming would be accomplished by using solid-state devices to switch input and output beams along different fiber-optic paths. Because of the lack of moving parts, these instruments could be extraordinarily reliable, rugged, and long-lasting. An instrument of this type would include an optical transmitter that would send out a laser pulse along a chosen direction to a target. An optical receiver coaligned with the transmitter would measure the temporally varying intensity of laser light reflected from the target to determine the distance and surface characteristics of the target. The transmitter would be a combination of devices for generating precise directional laser illumination. It would include a pulsed laser, the output of which would be coupled into a fiber-optic cable with a fan-out and solid-state optical switches that would enable switching of the laser beam onto one or more optical fibers terminated at known locations in an array on a face at the focal plane of a telescope. The array would be imaged by the telescope onto the target space. The receiver optical system could share the aforementioned telescope with the transmitter or could include a separate telescope aimed in the same direction as that of the transmitting telescope. In either case, light reflected

  13. [Target and non-target screening of volatile organic compounds in industrial exhaust gas using thermal desorption-gas chromatography-mass spectrometry].

    PubMed

    Ma, Huilian; Jin, Jing; Li, Yun; Chen, Jiping

    2017-10-08

    A method of comprehensive screening of the target and non-target volatile organic compounds (VOCs) in industrial exhaust gas using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) has been developed. In this paper, two types of solid phase adsorption column were compared, and the Tenex SS TD Tube was selected. The analytes were enriched into the adsorption tube by constant flow sampling, and detected by TD-GC-MS in full scan mode. Target compounds were quantified by internal standard method, and the quantities of non-target compounds were calculated by response coefficient of toluene. The method detection limits (MDLs) for the 24 VOCs were 1.06 to 5.44 ng, and MDLs could also be expressed as 0.004 to 0.018 mg/m 3 assuming that the sampling volume was 300 mL. The average recoveries were in the range of 78.4% to 89.4% with the relative standard deviations (RSDs) of 3.9% to 14.4% ( n =7). The established analytical method was applied for the comprehensive screening of VOCs in a waste incineration power plant in Dalian city. Twenty-nine VOCs were identified. In these compounds, only five VOCs were the target compounds set in advance, which accounted for 26.7% of the total VOCs identified. Therefore, this study further proved the importance of screening non-target compounds in the analysis of VOCs in industrial exhaust gas, and has certain reference significance for the complete determination of VOCs distribution.

  14. Coil End Parts Development Using BEND and Design for MQXF by LARP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Miao; Ambrosio, G.; Bermudez, S. Izquierdo

    2016-09-06

    End parts are critical components for saddle-shaped coils. They have a structural function where the cables are deformed in order to cross over the magnet aperture. Based on the previous design of the US LARP program for 90 mm aperture quadrupoles (TQ/LQ) and 120 mm aperture quadrupoles (HQ/LHQ) using BEND, the coil ends of the low-β quadruples (MQXF) for the HiLumi LHC upgrade were developed. This paper shows the design of the MQXF coil ends, the analysis of the coil ends during the coil fabrication, the autopsy analysis of the coil ends and the feedback to BEND parameters.

  15. Cortical Surface Registration for Image-Guided Neurosurgery Using Laser-Range Scanning

    PubMed Central

    Sinha, Tuhin K.; Cash, David M.; Galloway, Robert L.; Weil, Robert J.

    2013-01-01

    In this paper, a method of acquiring intraoperative data using a laser range scanner (LRS) is presented within the context of model-updated image-guided surgery. Registering textured point clouds generated by the LRS to tomographic data is explored using established point-based and surface techniques as well as a novel method that incorporates geometry and intensity information via mutual information (SurfaceMI). Phantom registration studies were performed to examine accuracy and robustness for each framework. In addition, an in vivo registration is performed to demonstrate feasibility of the data acquisition system in the operating room. Results indicate that SurfaceMI performed better in many cases than point-based (PBR) and iterative closest point (ICP) methods for registration of textured point clouds. Mean target registration error (TRE) for simulated deep tissue targets in a phantom were 1.0 ± 0.2, 2.0 ± 0.3, and 1.2 ± 0.3 mm for PBR, ICP, and SurfaceMI, respectively. With regard to in vivo registration, the mean TRE of vessel contour points for each framework was 1.9 ± 1.0, 0 9 ± 0.6, and 1.3 ± 0.5 for PBR, ICP, and SurfaceMI, respectively. The methods discussed in this paper in conjunction with the quantitative data provide impetus for using LRS technology within the model-updated image-guided surgery framework. PMID:12906252

  16. Production of copper-64 and gallium-68 with a medical cyclotron using liquid targets

    NASA Astrophysics Data System (ADS)

    Alves, F.; Alves, V. H. P.; Do Carmo, S. J. C.; Neves, A. C. B.; Silva, M.; Abrunhosa, A. J.

    2017-06-01

    This work describes the production of two clinically relevant metal radioisotopes 64Cu and 68Ga with a medical cyclotron by the irradiation of liquid targets. New results are presented for the implementation of this methodology in a fully automated system, using commercially available equipment. Liquid target solutions containing enriched 64Ni and 68Zn were loaded, bombarded and transferred to synthesis modules where a purified solution containing the desired radiometal is obtained and can then be used to further radiolabeling within only one hour after End-Of-Bombardment (EOB). Typical production runs using enriched material lead to the production of 5 GBq and 6 GBq (0.14 MBq/(μAh ṡ mg) and 1.5 MBq/(μAh ṡ mg)) of 64Cu and 68Ga; although the technique can be used to obtain up to 25 GBq and 40 GBq, respectively, by simply scaling up the amount of the enriched material. Purified solutions containing 64Cu and 68Ga were obtained within 30 min after EOB and used to produce 64Cu-ATSM and 68Ga-DOTA-NOC, respectively, with quality parameters suitable for human use.

  17. The relationship between target joints and direct resource use in severe haemophilia.

    PubMed

    O'Hara, Jamie; Walsh, Shaun; Camp, Charlotte; Mazza, Giuseppe; Carroll, Liz; Hoxer, Christina; Wilkinson, Lars

    2018-01-16

    Target joints are a common complication of severe haemophilia. While factor replacement therapy constitutes the majority of costs in haemophilia, the relationship between target joints and non drug-related direct costs (NDDCs) has not been studied. Data on haemophilia patients without inhibitors was drawn from the 'Cost of Haemophilia across Europe - a Socioeconomic Survey' (CHESS) study, a cost assessment in severe haemophilia A and B across five European countries (France, Germany, Italy, Spain, and the United Kingdom) in which 139 haemophilia specialists provided demographic and clinical information for 1285 adult patients. NDDCs were calculated using publicly available cost data, including 12-month ambulatory and secondary care activity: haematologist and other specialist consultant consultations, medical tests and examinations, bleed-related hospital admissions, and payments to professional care providers. A generalized linear model was developed to investigate the relationship between NDDCs and target joints (areas of chronic synovitis), adjusted for patient covariates. Five hundred and thirteen patients (42% of the sample) had no diagnosed target joints; a total of 1376 target joints (range 1-10) were recorded in the remaining 714 patients. Mean adjusted NDDCs for persons with no target joints were EUR 3134 (standard error (SE) EUR 158); for persons with one or more target joints, mean adjusted NDDCs were EUR 3913 (SE EUR 157; average mean effect EUR 779; p < 0.001). Our analysis suggests that the presence of one or more target joints has a significant impact on NDDCs for patients with severe haemophilia, ceteris paribus. Prevention and management of target joints should be an important consideration of managing haemophilia patients.

  18. Highly Complementary Target RNAs Promote Release of Guide RNAs from Human Argonaute2

    PubMed Central

    De, Nabanita; Young, Lisa; Lau, Pick-Wei; Meisner, Nicole-Claudia; Morrissey, David V.; MacRae, Ian J.

    2013-01-01

    SUMMARY Argonaute proteins use small RNAs to guide the silencing of complementary target RNAs in many eukaryotes. Although small RNA biogenesis pathways are well studied, mechanisms for removal of guide RNAs from Argonaute are poorly understood. Here we show that the Argonaute2 (Ago2) guide RNA complex is extremely stable, with a half-life on the order of days. However, highly complementary target RNAs destabilize the complex and significantly accelerate release of the guide RNA from Ago2. This “unloading” activity can be enhanced by mismatches between the target and the guide 5′ end and attenuated by mismatches to the guide 3′ end. The introduction of 3′ mismatches leads to more potent silencing of abundant mRNAs in mammalian cells. These findings help to explain why the 3′ ends of mammalian microRNAs (miRNAs) rarely match their targets, suggest a mechanism for sequence-specific small RNA turnover, and offer insights for controlling small RNAs in mammalian cells. PMID:23664376

  19. 15 CFR 744.5 - Restrictions on certain maritime nuclear propulsion end-uses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... nuclear propulsion end-uses. 744.5 Section 744.5 Commerce and Foreign Trade Regulations Relating to... nuclear propulsion end-uses. (a) General prohibition. In addition to the license requirements for items... item is for use in connection with a foreign maritime nuclear propulsion project. This prohibition...

  20. 15 CFR 744.5 - Restrictions on certain maritime nuclear propulsion end-uses.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... nuclear propulsion end-uses. 744.5 Section 744.5 Commerce and Foreign Trade Regulations Relating to... nuclear propulsion end-uses. (a) General prohibition. In addition to the license requirements for items... item is for use in connection with a foreign maritime nuclear propulsion project. This prohibition...

  1. 15 CFR 744.5 - Restrictions on certain maritime nuclear propulsion end-uses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... nuclear propulsion end-uses. 744.5 Section 744.5 Commerce and Foreign Trade Regulations Relating to... nuclear propulsion end-uses. (a) General prohibition. In addition to the license requirements for items... item is for use in connection with a foreign maritime nuclear propulsion project. This prohibition...

  2. 15 CFR 744.5 - Restrictions on certain maritime nuclear propulsion end-uses.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... nuclear propulsion end-uses. 744.5 Section 744.5 Commerce and Foreign Trade Regulations Relating to... nuclear propulsion end-uses. (a) General prohibition. In addition to the license requirements for items... item is for use in connection with a foreign maritime nuclear propulsion project. This prohibition...

  3. 15 CFR 744.5 - Restrictions on certain maritime nuclear propulsion end-uses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... nuclear propulsion end-uses. 744.5 Section 744.5 Commerce and Foreign Trade Regulations Relating to... nuclear propulsion end-uses. (a) General prohibition. In addition to the license requirements for items... item is for use in connection with a foreign maritime nuclear propulsion project. This prohibition...

  4. Power and the objectification of social targets.

    PubMed

    Gruenfeld, Deborah H; Inesi, M Ena; Magee, Joe C; Galinsky, Adam D

    2008-07-01

    Objectification has been defined historically as a process of subjugation whereby people, like objects, are treated as means to an end. The authors hypothesized that objectification is a response to social power that involves approaching useful social targets regardless of the value of their other human qualities. Six studies found that under conditions of power, approach toward a social target was driven more by the target's usefulness, defined in terms of the perceiver's goals, than in low-power and baseline conditions. This instrumental response to power, which was linked to the presence of an active goal, was observed using multiple instantiations of power, different measures of approach, a variety of goals, and several types of instrumental and noninstrumental target attributes. Implications for research on the psychology of power, automatic goal pursuit, and self-objectification theory are discussed.

  5. Stare and chase of space debris targets using real-time derived pointing data

    NASA Astrophysics Data System (ADS)

    Steindorfer, Michael A.; Kirchner, Georg; Koidl, Franz; Wang, Peiyuan; Antón, Alfredo; Fernández Sánchez, Jaime; Merz, Klaus

    2017-09-01

    We successfully demonstrate Stare & Chase: Space debris laser ranging to uncooperative targets has been achieved without a priori knowledge of any orbital information. An analog astronomy CCD with a standard objective, piggyback mounted on our 50 cm Graz SLR receive telescope, 'stares' into the sky in a fixed direction. The CCD records the stellar background within a field of view of approx. 7°. From the stellar X/Y positions on the sensor a plate solving algorithm determines the pointing data of the image center with an accuracy of approx. 15 arc seconds. If a sunlit target passes through this field of view, its equatorial coordinates are calculated, stored and a Consolidated Prediction Format (CPF) file is created in near real time. The derived CPF data is used to start laser ranging ('chase' the object) within the same pass to retrieve highly accurate distance information. A comparison of Stare & Chase CPFs with standard TLE predictions shows the possibilities and limits of this method.

  6. Detection of Moving Targets Using Soliton Resonance Effect

    NASA Technical Reports Server (NTRS)

    Kulikov, Igor K.; Zak, Michail

    2013-01-01

    The objective of this research was to develop a fundamentally new method for detecting hidden moving targets within noisy and cluttered data-streams using a novel "soliton resonance" effect in nonlinear dynamical systems. The technique uses an inhomogeneous Korteweg de Vries (KdV) equation containing moving-target information. Solution of the KdV equation will describe a soliton propagating with the same kinematic characteristics as the target. The approach uses the time-dependent data stream obtained with a sensor in form of the "forcing function," which is incorporated in an inhomogeneous KdV equation. When a hidden moving target (which in many ways resembles a soliton) encounters the natural "probe" soliton solution of the KdV equation, a strong resonance phenomenon results that makes the location and motion of the target apparent. Soliton resonance method will amplify the moving target signal, suppressing the noise. The method will be a very effective tool for locating and identifying diverse, highly dynamic targets with ill-defined characteristics in a noisy environment. The soliton resonance method for the detection of moving targets was developed in one and two dimensions. Computer simulations proved that the method could be used for detection of singe point-like targets moving with constant velocities and accelerations in 1D and along straight lines or curved trajectories in 2D. The method also allows estimation of the kinematic characteristics of moving targets, and reconstruction of target trajectories in 2D. The method could be very effective for target detection in the presence of clutter and for the case of target obscurations.

  7. The airborne laser ranging system, its capabilities and applications

    NASA Technical Reports Server (NTRS)

    Kahn, W. D.; Degnan, J. J.; Englar, T. S., Jr.

    1982-01-01

    The airborne laser ranging system is a multibeam short pulse laser ranging system on board an aircraft. It simultaneously measures the distances between the aircraft and six laser retroreflectors (targets) deployed on the Earth's surface. The system can interrogate over 100 targets distributed over an area of 25,000 sq, kilometers in a matter of hours. Potentially, a total of 1.3 million individual range measurements can be made in a six hour flight. The precision of these range measurements is approximately + or - 1 cm. These measurements are used in procedure which is basically an extension of trilateration techniques to derive the intersite vector between the laser ground targets. By repeating the estimation of the intersite vector, strain and strain rate errors can be estimated. These quantities are essential for crustal dynamic studies which include determination and monitoring of regional strain in the vicinity of active fault zones, land subsidence, and edifice building preceding volcanic eruptions.

  8. Comprehensive target populations for current active safety systems using national crash databases.

    PubMed

    Kusano, Kristofer D; Gabler, Hampton C

    2014-01-01

    The objective of active safety systems is to prevent or mitigate collisions. A critical component in the design of active safety systems is the identification of the target population for a proposed system. The target population for an active safety system is that set of crashes that a proposed system could prevent or mitigate. Target crashes have scenarios in which the sensors and algorithms would likely activate. For example, the rear-end crash scenario, where the front of one vehicle contacts another vehicle traveling in the same direction and in the same lane as the striking vehicle, is one scenario for which forward collision warning (FCW) would be most effective in mitigating or preventing. This article presents a novel set of precrash scenarios based on coded variables from NHTSA's nationally representative crash databases in the United States. Using 4 databases (National Automotive Sampling System-General Estimates System [NASS-GES], NASS Crashworthiness Data System [NASS-CDS], Fatality Analysis Reporting System [FARS], and National Motor Vehicle Crash Causation Survey [NMVCCS]) the scenarios developed in this study can be used to quantify the number of police-reported crashes, seriously injured occupants, and fatalities that are applicable to proposed active safety systems. In this article, we use the precrash scenarios to identify the target populations for FCW, pedestrian crash avoidance systems (PCAS), lane departure warning (LDW), and vehicle-to-vehicle (V2V) or vehicle-to-infrastructure (V2I) systems. Crash scenarios were derived using precrash variables (critical event, accident type, precrash movement) present in all 4 data sources. This study found that these active safety systems could potentially mitigate approximately 1 in 5 of all severity and serious injury crashes in the United States and 26 percent of fatal crashes. Annually, this corresponds to 1.2 million all severity, 14,353 serious injury (MAIS 3+), and 7412 fatal crashes. In addition

  9. Using Flexible Busing to Meet Average Class Size Targets

    ERIC Educational Resources Information Center

    Felt, Andrew J.; Koelemay, Ryan; Richter, Alexander

    2008-01-01

    This article describes a method of flexible redistricting for K-12 public school districts that allows students from the same geographical region to be bused to different schools, with the goal of meeting average class size (ACS) target ranges. Results of a case study on a geographically large school district comparing this method to a traditional…

  10. The Design of New HIV-IN Tethered Bifunctional Inhibitors using Multiple Microdomain Targeted Docking.

    PubMed

    Ciubotaru, Mihai; Musat, Mihaela Georgiana; Surleac, Marius; Ionita, Elena; Petrescu, Andrei Jose; Abele, Edgars; Abele, Ramona

    2018-04-05

    Currently used antiretroviral HIV therapy drugs exclusively target critical groups in the enzymes essential for the viral life cycle. Increased mutagenesis of their genes, changes these viral enzymes which once mutated can evade therapeutic targeting, effects which confer drug resistance. To circumvent this, our review addresses a strategy to design and derive HIV-Integrase (HIV-IN) inhibitors which simultaneously target two IN functional domains, rendering it inactive even if the enzyme accumulates many mutations. First we review the enzymatic role of IN to insert the copied viral DNA into a chromosome of the host T lymphocyte, highlighting its main functional and structural features to be subjected to inhibitory action. From a functional and structural perspective we present all classes of HIV-IN inhibitors with their most representative candidates. For each chosen compound we also explain its mechanism of IN inhibition. We use the recently resolved cryo EM IN tetramer intasome DNA complex [1] onto which we dock various reference IN inhibitory chemical scaffolds such as to target adjacent functional IN domains. Pairing compounds with complementary activity, which dock in the vicinity of a IN structural microdomain, we design bifunctional new drugs which may not only be more resilient to IN mutations but also may be more potent inhibitors than their original counterparts. In the end of our review we propose synthesis pathways to link such paired compounds with enhanced synergistic IN inhibitory effects. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. Research on range-gated laser active imaging seeker

    NASA Astrophysics Data System (ADS)

    You, Mu; Wang, PengHui; Tan, DongJie

    2013-09-01

    Compared with other imaging methods such as millimeter wave imaging, infrared imaging and visible light imaging, laser imaging provides both a 2-D array of reflected intensity data as well as 2-D array of range data, which is the most important data for use in autonomous target acquisition .In terms of application, it can be widely used in military fields such as radar, guidance and fuse. In this paper, we present a laser active imaging seeker system based on range-gated laser transmitter and sensor technology .The seeker system presented here consist of two important part, one is laser image system, which uses a negative lens to diverge the light from a pulse laser to flood illuminate a target, return light is collected by a camera lens, each laser pulse triggers the camera delay and shutter. The other is stabilization gimbals, which is designed to be a rotatable structure both in azimuth and elevation angles. The laser image system consists of transmitter and receiver. The transmitter is based on diode pumped solid-state lasers that are passively Q-switched at 532nm wavelength. A visible wavelength was chosen because the receiver uses a Gen III image intensifier tube with a spectral sensitivity limited to wavelengths less than 900nm.The receiver is image intensifier tube's micro channel plate coupled into high sensitivity charge coupled device camera. The image has been taken at range over one kilometer and can be taken at much longer range in better weather. Image frame frequency can be changed according to requirement of guidance with modifiable range gate, The instantaneous field of views of the system was found to be 2×2 deg. Since completion of system integration, the seeker system has gone through a series of tests both in the lab and in the outdoor field. Two different kinds of buildings have been chosen as target, which is located at range from 200m up to 1000m.To simulate dynamic process of range change between missile and target, the seeker system has

  12. Emerging Roles for MicroRNAs in Diabetic Microvascular Disease: Novel Targets for Therapy

    PubMed Central

    Zhang, Yu; Sun, Xinghui; Icli, Basak

    2017-01-01

    Chronic, low-grade systemic inflammation and impaired microvascular function are critical hallmarks in the development of insulin resistance. Accordingly, insulin resistance is a major risk factor for type 2 diabetes and cardiovascular disease. Accumulating studies demonstrate that restoration of impaired function of the diabetic macro- and microvasculature may ameliorate a range of cardiovascular disease states and diabetes-associated complications. In this review, we focus on the emerging role of microRNAs (miRNAs), noncoding RNAs that fine-tune target gene expression and signaling pathways, in insulin-responsive tissues and cell types important for maintaining optimal vascular homeostasis and preventing the sequelae of diabetes-induced end organ injury. We highlight current pathophysiological paradigms of miRNAs and their targets involved in regulating the diabetic microvasculature in a range of diabetes-associated complications such as retinopathy, nephropathy, wound healing, and myocardial injury. We provide an update of the potential use of circulating miRNAs diagnostically in type I or type II diabetes. Finally, we discuss emerging delivery platforms for manipulating miRNA expression or function as the next frontier in therapeutic intervention to improve diabetes-associated microvascular dysfunction and its attendant clinical consequences. PMID:28323921

  13. T-wave end detection using neural networks and Support Vector Machines.

    PubMed

    Suárez-León, Alexander Alexeis; Varon, Carolina; Willems, Rik; Van Huffel, Sabine; Vázquez-Seisdedos, Carlos Román

    2018-05-01

    In this paper we propose a new approach for detecting the end of the T-wave in the electrocardiogram (ECG) using Neural Networks and Support Vector Machines. Both, Multilayer Perceptron (MLP) neural networks and Fixed-Size Least-Squares Support Vector Machines (FS-LSSVM) were used as regression algorithms to determine the end of the T-wave. Different strategies for selecting the training set such as random selection, k-means, robust clustering and maximum quadratic (Rényi) entropy were evaluated. Individual parameters were tuned for each method during training and the results are given for the evaluation set. A comparison between MLP and FS-LSSVM approaches was performed. Finally, a fair comparison of the FS-LSSVM method with other state-of-the-art algorithms for detecting the end of the T-wave was included. The experimental results show that FS-LSSVM approaches are more suitable as regression algorithms than MLP neural networks. Despite the small training sets used, the FS-LSSVM methods outperformed the state-of-the-art techniques. FS-LSSVM can be successfully used as a T-wave end detection algorithm in ECG even with small training set sizes. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Complex background suppression using global-local registration strategy for the detection of small-moving target on moving platform

    NASA Astrophysics Data System (ADS)

    Zou, Tianhao; Zuo, Zhengrong

    2018-02-01

    Target detection is a very important and basic problem of computer vision and image processing. The most often case we meet in real world is a detection task for a moving-small target on moving platform. The commonly used methods, such as Registration-based suppression, can hardly achieve a desired result. To crack this hard nut, we introduce a Global-local registration based suppression method. Differ from the traditional ones, the proposed Global-local Registration Strategy consider both the global consistency and the local diversity of the background, obtain a better performance than normal background suppression methods. In this paper, we first discussed the features about the small-moving target detection on unstable platform. Then we introduced a new strategy and conducted an experiment to confirm its noisy stability. In the end, we confirmed the background suppression method based on global-local registration strategy has a better perform in moving target detection on moving platform.

  15. The Technology Acceptance Model for Resource-Limited Settings (TAM-RLS): A Novel Framework for Mobile Health Interventions Targeted to Low-Literacy End-Users in Resource-Limited Settings.

    PubMed

    Campbell, Jeffrey I; Aturinda, Isaac; Mwesigwa, Evans; Burns, Bridget; Santorino, Data; Haberer, Jessica E; Bangsberg, David R; Holden, Richard J; Ware, Norma C; Siedner, Mark J

    2017-11-01

    Although mobile health (mHealth) technologies have shown promise in improving clinical care in resource-limited settings (RLS), they are infrequently brought to scale. One limitation to the success of many mHealth interventions is inattention to end-user acceptability, which is an important predictor of technology adoption. We conducted in-depth interviews with 43 people living with HIV in rural Uganda who had participated in a clinical trial of a short messaging system (SMS)-based intervention designed to prompt return to clinic after an abnormal laboratory test. Interviews focused on established features of technology acceptance models, including perceived ease of use and perceived usefulness, and included open-ended questions to gain insight into unexplored issues related to the intervention's acceptability. We used conventional (inductive) and direct content analysis to derive categories describing use behaviors and acceptability. Interviews guided development of a proposed conceptual framework, the technology acceptance model for resource-limited settings (TAM-RLS). This framework incorporates both classic technology acceptance model categories as well as novel factors affecting use in this setting. Participants described how SMS message language, phone characteristics, and experience with similar technologies contributed to the system's ease of use. Perceived usefulness was shaped by the perception that the system led to augmented HIV care services and improved access to social support from family and colleagues. Emergent themes specifically related to mHealth acceptance among PLWH in Uganda included (1) the importance of confidentiality, disclosure, and stigma, and (2) the barriers and facilitators downstream from the intervention that impacted achievement of the system's target outcome. The TAM-RLS is a proposed model of mHealth technology acceptance based upon end-user experiences in rural Uganda. Although the proposed model requires validation, the TAM

  16. LWS/SET End-to-End Data System

    NASA Technical Reports Server (NTRS)

    Giffin, Geoff; Sherman, Barry; Colon, Gilberto (Technical Monitor)

    2002-01-01

    This paper describes the concept for the End-to-End Data System that will support NASA's Living With a Star Space Environment Testbed missions. NASA has initiated the Living With a Star (LWS) Program to develop a better scientific understanding to address the aspects of the connected Sun-Earth system that affect life and society. A principal goal of the program is to bridge the gap.between science, engineering, and user application communities. The Space Environment Testbed (SET) Project is one element of LWS. The Project will enable future science, operational, and commercial objectives in space and atmospheric environments by improving engineering approaches to the accommodation and/or mitigation of the effects of solar variability on technological systems. The End-to-end data system allows investigators to access the SET control center, command their experiments, and receive data from their experiments back at their home facility, using the Internet. The logical functioning of major components of the end-to-end data system are described, including the GSFC Payload Operations Control Center (POCC), SET Payloads, the GSFC SET Simulation Lab, SET Experiment PI Facilities, and Host Systems. Host Spacecraft Operations Control Centers (SOCC) and the Host Spacecraft are essential links in the end-to-end data system, but are not directly under the control of the SET Project. Formal interfaces will be established between these entities and elements of the SET Project. The paper describes data flow through the system, from PI facilities connecting to the SET operations center via the Internet, communications to SET carriers and experiments via host systems, to telemetry returns to investigators from their flight experiments. It also outlines the techniques that will be used to meet mission requirements, while holding development and operational costs to a minimum. Additional information is included in the original extended abstract.

  17. Gene targeting in mosquito cells: a demonstration of 'knockout' technology in extrachromosomal gene arrays

    PubMed Central

    Eggleston, Paul; Zhao, Yuguang

    2001-01-01

    Background Gene targeting would offer a number of advantages over current transposon-based strategies for insect transformation. These include freedom from both position effects associated with quasi-random integration and concerns over transgene instability mediated by endogenous transposases, independence from phylogenetic restrictions on transposon mobility and the ability to generate gene knockouts. Results We describe here our initial investigations of gene targeting in the mosquito. The target site was a hygromycin resistance gene, stably maintained as part of an extrachromosomal array. Using a promoter-trap strategy to enrich for targeted events, a neomycin resistance gene was integrated into the target site. This resulted in knockout of hygromycin resistance concurrent with the expression of high levels of neomycin resistance from the resident promoter. PCR amplification of the targeted site generated a product that was specific to the targeted cell line and consistent with precise integration of the neomycin resistance gene into the 5' end of the hygromycin resistance gene. Sequencing of the PCR product and Southern analysis of cellular DNA subsequently confirmed this molecular structure. Conclusions These experiments provide the first demonstration of gene targeting in mosquito tissue and show that mosquito cells possess the necessary machinery to bring about precise integration of exogenous sequences through homologous recombination. Further development of these procedures and their extension to chromosomally located targets hold much promise for the exploitation of gene targeting in a wide range of medically and economically important insect species. PMID:11513755

  18. Space moving target detection using time domain feature

    NASA Astrophysics Data System (ADS)

    Wang, Min; Chen, Jin-yong; Gao, Feng; Zhao, Jin-yu

    2018-01-01

    The traditional space target detection methods mainly use the spatial characteristics of the star map to detect the targets, which can not make full use of the time domain information. This paper presents a new space moving target detection method based on time domain features. We firstly construct the time spectral data of star map, then analyze the time domain features of the main objects (target, stars and the background) in star maps, finally detect the moving targets using single pulse feature of the time domain signal. The real star map target detection experimental results show that the proposed method can effectively detect the trajectory of moving targets in the star map sequence, and the detection probability achieves 99% when the false alarm rate is about 8×10-5, which outperforms those of compared algorithms.

  19. Improved production and processing of ⁸⁹Zr using a solution target.

    PubMed

    Pandey, Mukesh K; Bansal, Aditya; Engelbrecht, Hendrik P; Byrne, John F; Packard, Alan B; DeGrado, Timothy R

    2016-01-01

    The objectives of the present work were to improve the cyclotron production yield of (89)Zr using a solution target, develop a practical synthesis of the hydroxamate resin used to process the target, and develop a biocompatible medium for (89)Zr elution from the hydroxamate resin. A new solution target (BMLT-2) with enhanced heat dissipation capabilities was designed by using helium-cooled dual foils (0.2 mm Al and 25 μ Havar) and an enhanced water-cooled, elongated solution cavity in the target insert. Irradiations were performed with 14 MeV protons on a 2M solution of yttrium nitrate in 1.25 M nitric acid at 40-μA beam current for 2 h in a closed system. Zirconium-89 was separated from Y by use of a hydroxamate resin. A one-pot synthesis of hydroxamate resin was accomplished by activating the carboxylate groups on a carboxymethyl cation exchange resin using methyl chloroformate followed by reaction with hydroxylamine hydrochloride. After trapping of (89)Zr on hydroxamate resin and rinsing the resin with HCl and water to release Y, (89)Zr was eluted with 1.2 M K2HPO4/KH2PO4 buffer (pH3.5). ICP-MS was used to measure metal contaminants in the final (89)Zr solution. The BMLT-2 target produced 349±49 MBq (9.4±1.2 mCi) of (89)Zr at the end of irradiation with a specific activity of 1.18±0.79 GBq/μg. The hydroxamate resin prepared using the new synthesis method showed a trapping efficiency of 93% with a 75 mg resin bed and 96-97% with a 100-120 mg resin bed. The elution efficiency of (89)Zr with 1.2M K2HPO4/KH2PO4 solution was found to be 91.7±3.7%, compared to >95% for 1 M oxalic acid. Elution with phosphate buffer gave very small levels of metal contaminants: Al=0.40-0.86 μg (n=2), Fe=1.22±0.71 μg (n=3), Y=0.29 μg (n=1). The BMLT-2 target allowed doubling of the beam current for production of (89)Zr, resulting in a greater than 2-fold increase in production yield in comparison with a conventional liquid target. The new one-pot synthesis of hydroxamate

  20. Study of pseudo noise CW diode laser for ranging applications

    NASA Technical Reports Server (NTRS)

    Lee, Hyo S.; Ramaswami, Ravi

    1992-01-01

    A new Pseudo Random Noise (PN) modulated CW diode laser radar system is being developed for real time ranging of targets at both close and large distances (greater than 10 KM) to satisy a wide range of applications: from robotics to future space applications. Results from computer modeling and statistical analysis, along with some preliminary data obtained from a prototype system, are presented. The received signal is averaged for a short time to recover the target response function. It is found that even with uncooperative targets, based on the design parameters used (200-mW laser and 20-cm receiver), accurate ranging is possible up to about 15 KM, beyond which signal to noise ratio (SNR) becomes too small for real time analog detection.

  1. Use of spring-roll EAP actuator applied as end-effector of a hyper-redundant robot

    NASA Astrophysics Data System (ADS)

    Errico, Gianmarco; Fava, Victor; Resta, Ferruccio; Ripamonti, Francesco

    2015-04-01

    This paper presents a hyper-redundant continuous robot used to perform work in places which humans can not reach. This type of robot is generally a bio-inspired solution, it is composed by a lot of flexible segments driven by multiple actuators and its dynamics is described by a lot degrees of freedom. In this paper a model composed of some rigid links connected to each other by revolution joint is presented. In each link a torsional spring is added in order to simulate the resistant torque between the links and the interactions among the cables and the robot during the relative rotation. Moreover a type of EAP actuator, called spring roll, is used as the end-effector of the robot. Through a suitable sensor, such as a camera, the spring roll allows to track a target and it closes the control loop on the robot to follow it.

  2. 7 CFR 782.11 - Extent to which commodities are subject to end-use certificate regulations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 7 2014-01-01 2014-01-01 false Extent to which commodities are subject to end-use... (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS END-USE CERTIFICATE PROGRAM Implementation of the End-Use Certificate Program § 782.11 Extent to which commodities are subject to end-use...

  3. 7 CFR 782.11 - Extent to which commodities are subject to end-use certificate regulations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Extent to which commodities are subject to end-use... (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS END-USE CERTIFICATE PROGRAM Implementation of the End-Use Certificate Program § 782.11 Extent to which commodities are subject to end-use...

  4. 7 CFR 782.11 - Extent to which commodities are subject to end-use certificate regulations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 7 2011-01-01 2011-01-01 false Extent to which commodities are subject to end-use... (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS END-USE CERTIFICATE PROGRAM Implementation of the End-Use Certificate Program § 782.11 Extent to which commodities are subject to end-use...

  5. 7 CFR 782.11 - Extent to which commodities are subject to end-use certificate regulations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 7 2012-01-01 2012-01-01 false Extent to which commodities are subject to end-use... (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS END-USE CERTIFICATE PROGRAM Implementation of the End-Use Certificate Program § 782.11 Extent to which commodities are subject to end-use...

  6. 7 CFR 782.11 - Extent to which commodities are subject to end-use certificate regulations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 7 2013-01-01 2013-01-01 false Extent to which commodities are subject to end-use... (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS END-USE CERTIFICATE PROGRAM Implementation of the End-Use Certificate Program § 782.11 Extent to which commodities are subject to end-use...

  7. Global patterns of protection of elevational gradients in mountain ranges.

    PubMed

    Elsen, Paul R; Monahan, William B; Merenlender, Adina M

    2018-05-21

    Protected areas (PAs) that span elevational gradients enhance protection for taxonomic and phylogenetic diversity and facilitate species range shifts under climate change. We quantified the global protection of elevational gradients by analyzing the elevational distributions of 44,155 PAs in 1,010 mountain ranges using the highest resolution digital elevation models available. We show that, on average, mountain ranges in Africa and Asia have the lowest elevational protection, ranges in Europe and South America have intermediate elevational protection, and ranges in North America and Oceania have the highest elevational protection. We use the Convention on Biological Diversity's Aichi Target 11 to assess the proportion of elevational gradients meeting the 17% suggested minimum target and examine how different protection categories contribute to elevational protection. When considering only strict PAs [International Union for Conservation of Nature (IUCN) categories I-IV, n = 24,706], nearly 40% of ranges do not contain any PAs, roughly half fail to meet the 17% target at any elevation, and ∼75% fail to meet the target throughout ≥50% of the elevational gradient. Observed elevational protection is well below optimal, and frequently below a null model of elevational protection. Including less stringent PAs (IUCN categories V-VI and nondesignated PAs, n = 19,449) significantly enhances elevational protection for most continents, but several highly biodiverse ranges require new or expanded PAs to increase elevational protection. Ensuring conservation outcomes for PAs with lower IUCN designations as well as strategically placing PAs to better represent and connect elevational gradients will enhance ecological representation and facilitate species range shifts under climate change. Copyright © 2018 the Author(s). Published by PNAS.

  8. Speed of Sound versus Temperature Using PVC Pipes Open at Both Ends

    ERIC Educational Resources Information Center

    Bacon, Michael E.

    2012-01-01

    In this paper we investigate the speed of sound in air as a function of temperature using a simple and inexpensive apparatus. For this experiment it is essential that the appropriate end corrections be taken into account. In a recent paper the end corrections for 2-in i.d. (5.04-cm) PVC pipes open at both ends were investigated. The air column…

  9. Adaptation and validation of a commercial head phantom for cranial radiosurgery dosimetry end-to-end audit.

    PubMed

    Dimitriadis, Alexis; Palmer, Antony L; Thomas, Russell A S; Nisbet, Andrew; Clark, Catharine H

    2017-06-01

    To adapt and validate an anthropomorphic head phantom for use in a cranial radiosurgery audit. Two bespoke inserts were produced for the phantom: one for providing the target and organ at risk for delineation and the other for performing dose measurements. The inserts were tested to assess their positional accuracy. A basic treatment plan dose verification with an ionization chamber was performed to establish a baseline accuracy for the phantom and beam model. The phantom and inserts were then used to perform dose verification measurements of a radiosurgery plan. The dose was measured with alanine pellets, EBT extended dose film and a plastic scintillation detector (PSD). Both inserts showed reproducible positioning (±0.5 mm) and good positional agreement between them (±0.6 mm). The basic treatment plan measurements showed agreement to the treatment planning system (TPS) within 0.5%. Repeated film measurements showed consistent gamma passing rates with good agreement to the TPS. For 2%-2 mm global gamma, the mean passing rate was 96.7% and the variation in passing rates did not exceed 2.1%. The alanine pellets and PSD showed good agreement with the TPS (-0.1% and 0.3% dose difference in the target) and good agreement with each other (within 1%). The adaptations to the phantom showed acceptable accuracies. The presence of alanine and PSD do not affect film measurements significantly, enabling simultaneous measurements by all three detectors. Advances in knowledge: A novel method for thorough end-to-end test of radiosurgery, with capability to incorporate all steps of the clinical pathway in a time-efficient and reproducible manner, suitable for a national audit.

  10. Exploring end of life priorities in Saudi males: usefulness of Q-methodology.

    PubMed

    Hammami, Muhammad M; Al Gaai, Eman; Hammami, Safa; Attala, Sahar

    2015-11-26

    Quality end-of-life care depends on understanding patients' end-of-life choices. Individuals and cultures may hold end-of-life priorities at different hierarchy. Forced ranking rather than independent rating, and by-person factor analysis rather than averaging may reveal otherwise masked typologies. We explored Saudi males' forced-ranked, end-of-life priorities and dis-priorities. Respondents (n = 120) rank-ordered 47 opinion statements on end-of-life care following a 9-category symmetrical distribution. Statements' scores were analyzed by averaging analysis and factor analysis (Q-methodology). Respondents' mean age was 32.1 years (range, 18-65); 52% reported average religiosity, 88 and 83% ≥ very good health and life-quality, respectively, and 100% ≥ high school education. Averaging analysis revealed that the extreme five end-of-life priorities were to, be at peace with God, be able to say the statement of faith, maintain dignity, resolve conflicts, and have religious death rituals respected, respectively. The extreme five dis-priorities were to, die in the hospital, not receive intensive care if in coma, die at peak of life, be informed about impending death by family/friends rather than doctor, and keep medical status confidential from family/friends, respectively. Q-methodology classified 67% of respondents into five highly transcendent opinion types. Type-I (rituals-averse, family-caring, monitoring-coping, life-quality-concerned) and Type-V (rituals-apt, family-centered, neutral-coping, life-quantity-concerned) reported the lowest and highest religiosity, respectively. Type-II (rituals-apt, family-dependent, monitoring-coping, life-quantity-concerned) and Type-III (rituals-silent, self/family-neutral, avoidance-coping, life-quality & quantity-concerned) reported the best and worst life-quality, respectively. Type-I respondents were the oldest with the lowest general health, in contrast to Type-IV (rituals-apt, self-centered, monitoring

  11. Two-Way Gold Nanoparticle Label-Free Sensing of Specific Sequence and Small Molecule Targets Using Switchable Concatemers.

    PubMed

    Zhu, Longjiao; Shao, Xiangli; Luo, Yunbo; Huang, Kunlung; Xu, Wentao

    2017-05-19

    A two-way colorimetric biosensor based on unmodified gold nanoparticles (GNPs) and a switchable double-stranded DNA (dsDNA) concatemer have been demonstrated. Two hairpin probes (H1 and H2) were first designed that provided the fuels to assemble the dsDNA concatemers via hybridization chain reaction (HCR). A functional hairpin (FH) was rationally designed to recognize the target sequences. All the hairpins contained a single-stranded DNA (ssDNA) loop and sticky end to prevent GNPs from salt-induced aggregation. In the presence of target sequence, the capture probe blocked in the FH recognizes the target to form a duplex DNA, which causes the release of the initiator probe by FH conformational change. This process then starts the alternate-opening of H1 and H2 through HCR, and dsDNA concatemers grow from the target sequence. As a result, unmodified GNPs undergo salt-induced aggregation because the formed dsDNA concatemers are stiffer and provide less stabilization. A light purple-to-blue color variation was observed in the bulk solution, termed the light-off sensing way. Furthermore, H1 ingeniously inserted an aptamer sequence to generate dsDNA concatemers with multiple small molecule binding sites. In the presence of small molecule targets, concatemers can be disassembled into mixtures with ssDNA sticky ends. A blue-to-purple reverse color variation was observed due to the regeneration of the ssDNA, termed the light-on way. The two-way biosensor can detect both nucleic acids and small molecule targets with one sensing device. This switchable sensing element is label-free, enzyme-free, and sophisticated-instrumentation-free. The detection limits of both targets were below nanomolar.

  12. End-use energy consumption estimates for US commercial buildings, 1989

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belzer, D.B.; Wrench, L.E.; Marsh, T.L.

    An accurate picture of how energy is used in the nation`s stock of commercial buildings can serve a variety of program planning and policy needs within the Department of Energy, by utilities, and other groups seeking to improve the efficiency of energy use in the building sector. This report describes an estimation of energy consumption by end use based upon data from the 1989 Commercial Building Energy Consumption Survey (CBECS). The methodology used in the study combines elements of engineering simulations and statistical analysis to estimate end-use intensities for heating, cooling, ventilation, lighting, refrigeration, hot water, cooking, and miscellaneous equipment.more » Billing data for electricity and natural gas were first decomposed into weather and nonweather dependent loads. Subsequently, Statistical Adjusted Engineering (SAE) models were estimated by building type with annual data. The SAE models used variables such as building size, vintage, climate region, weekly operating hours, and employee density to adjust the engineering model predicted loads to the observed consumption. End-use consumption by fuel was estimated for each of the 5,876 buildings in the 1989 CBECS. The report displays the summary results for eleven separate building types as well as for the total US commercial building stock.« less

  13. Evaluation of marginal adaptation of root-end filling materials using scanning electron microscopy.

    PubMed

    Oliveira, Helder Fernandes; Gonçalves Alencar, Ana Helena; Poli Figueiredo, José Antônio; Guedes, Orlando Aguirre; de Almeida Decurcio, Daniel; Estrela, Carlos

    2013-01-01

    The importance of perfect apical seal in endodontics, more specifically in periradicular surgery, is the motivation/reason for development of root-end filling materials with favorable physical, chemical and biological characteristics. The aim of this in vitro study was to evaluate the marginal adaptation of root-end filling materials using scanning electron microscopy. Twenty five human maxillary anterior teeth were prepared using a K-File #50 to 1 mm short of the apical foramen and filled with gutta-percha and Sealapex using the lateral compaction technique. The apical 3 mm of the roots were sectioned perpendicularly to the long axis of the teeth. A 3-mm-deep root-end cavity was prepared using ultrasonic tips powered by an Enac ultrasonic unit. The teeth were randomly assigned to five groups according to the materials tested including IRM, amalgam, ProRoot MTA, Super-EBA and Epiphany/Resilon. Root-end cavities were filled with the materials prepared according to the manufacturers' instructions. The root apices were carefully prepared for sputter coating and later evaluation using Scanning Electron Microscope (SEM). The images of root-end fillings were divided into four quadrants and distributed into five categories according to the level of marginal adaptation between the root-end material and the root canal walls. The Fisher exact test with Bonferroni correction was used for statistical analysis. The level of significance was set at P = 0.005. SEM images showed the presence of gaps in the root-end filling materials. No significant difference was observed between the tested materials (P > 0.005). ProRoot MTA, IRM, amalgam, Super-EBA and Epiphany/Resilon showed similar marginal adaptation as root-end filling materials.

  14. Dead end1 is an essential partner of NANOS2 for selective binding of target RNAs in male germ cell development.

    PubMed

    Suzuki, Atsushi; Niimi, Yuki; Shinmyozu, Kaori; Zhou, Zhi; Kiso, Makoto; Saga, Yumiko

    2016-01-01

    RNA-binding proteins (RBPs) play important roles for generating various cell types in many developmental processes, including eggs and sperms. Nanos is widely known as an evolutionarily conserved RNA-binding protein implicated in germ cell development. Mouse NANOS2 interacts directly with the CCR4-NOT (CNOT) deadenylase complex, resulting in the suppression of specific RNAs. However, the mechanisms involved in target specificity remain elusive. We show that another RBP, Dead end1 (DND1), directly interacts with NANOS2 to load unique RNAs into the CNOT complex. This interaction is mediated by the zinc finger domain of NANOS2, which is essential for its association with target RNAs. In addition, the conditional deletion of DND1 causes the disruption of male germ cell differentiation similar to that observed in Nanos2-KO mice. Thus, DND1 is an essential partner for NANOS2 that leads to the degradation of specific RNAs. We also present the first evidence that the zinc finger domain of Nanos acts as a protein-interacting domain for another RBP, providing a novel insight into Nanos-mediated germ cell development. © 2015 The Authors.

  15. Cyberinfrastructure for End-to-End Environmental Explorations

    NASA Astrophysics Data System (ADS)

    Merwade, V.; Kumar, S.; Song, C.; Zhao, L.; Govindaraju, R.; Niyogi, D.

    2007-12-01

    The design and implementation of a cyberinfrastructure for End-to-End Environmental Exploration (C4E4) is presented. The C4E4 framework addresses the need for an integrated data/computation platform for studying broad environmental impacts by combining heterogeneous data resources with state-of-the-art modeling and visualization tools. With Purdue being a TeraGrid Resource Provider, C4E4 builds on top of the Purdue TeraGrid data management system and Grid resources, and integrates them through a service-oriented workflow system. It allows researchers to construct environmental workflows for data discovery, access, transformation, modeling, and visualization. Using the C4E4 framework, we have implemented an end-to-end SWAT simulation and analysis workflow that connects our TeraGrid data and computation resources. It enables researchers to conduct comprehensive studies on the impact of land management practices in the St. Joseph watershed using data from various sources in hydrologic, atmospheric, agricultural, and other related disciplines.

  16. Spectral Target Detection using Schroedinger Eigenmaps

    NASA Astrophysics Data System (ADS)

    Dorado-Munoz, Leidy P.

    Applications of optical remote sensing processes include environmental monitoring, military monitoring, meteorology, mapping, surveillance, etc. Many of these tasks include the detection of specific objects or materials, usually few or small, which are surrounded by other materials that clutter the scene and hide the relevant information. This target detection process has been boosted lately by the use of hyperspectral imagery (HSI) since its high spectral dimension provides more detailed spectral information that is desirable in data exploitation. Typical spectral target detectors rely on statistical or geometric models to characterize the spectral variability of the data. However, in many cases these parametric models do not fit well HSI data that impacts the detection performance. On the other hand, non-linear transformation methods, mainly based on manifold learning algorithms, have shown a potential use in HSI transformation, dimensionality reduction and classification. In target detection, non-linear transformation algorithms are used as preprocessing techniques that transform the data to a more suitable lower dimensional space, where the statistical or geometric detectors are applied. One of these non-linear manifold methods is the Schroedinger Eigenmaps (SE) algorithm that has been introduced as a technique for semi-supervised classification. The core tool of the SE algorithm is the Schroedinger operator that includes a potential term that encodes prior information about the materials present in a scene, and enables the embedding to be steered in some convenient directions in order to cluster similar pixels together. A completely novel target detection methodology based on SE algorithm is proposed for the first time in this thesis. The proposed methodology does not just include the transformation of the data to a lower dimensional space but also includes the definition of a detector that capitalizes on the theory behind SE. The fact that target pixels and

  17. Ketamine PCA for treatment of end-of-life neuropathic pain in pediatrics.

    PubMed

    Taylor, Matthew; Jakacki, Regina; May, Carol; Howrie, Denise; Maurer, Scott

    2015-12-01

    Control of neuropathic pain (NP) for children at end of life is challenging. Ketamine improves control of NP, but its use in children is not well described. We describe a retrospective case review of 14 children with terminal prognoses treated with ketamine patient-controlled analgesia (PCA) for management of opioid-refractory NP at the end of life. Median ketamine dose was 0.06 mg/kg/h (range 0.014-0.308 mg/kg/h) with a 0.05 mg/kg (range 0.03-0.5mg/kg) demand dose available every 15 minutes (range 10-60 minutes). All patients noted subjective pain relief with ketamine, and 79% had no adverse effects. Benzodiazepines limited neuropsychiatric side effects. Ketamine treatment arrested dose escalation of opioids in 64% of patients, and 79% were discharged to home hospice. Ketamine PCA is an effective, well-tolerated therapy for opioid-refractory NP in pediatric end-of-life care. © The Author(s) 2014.

  18. [Experience with the reference manager EndNote-EndLink].

    PubMed

    Reiss, M; Reiss, G

    1998-09-01

    A good reference management program should make it easy to record the elements of a reference: author's name, year of publication, title of article, etc. It should offer tools that let you find and retrieve references quickly, and it should be able to produce the bibliography in the format required for a particular publication. There are many computer programs, but very few stand out as truly useful, time saving, and work enhancing. One of them is EndNote-EndLink. We want to report our experience with this database manager. The functions and the use of the software package EndNote 2.3 for Windows are described. You can create your database or you can download batches of references from one of the popular searching services (e.g. MEDLINE). When you want to cite a reference you simply paste the reference wherever you want your in-text citation to appear. To prepare the bibliography, EndNote scans your article, replaces the place holders with citations and prints the list of references at the end of the manuscript, according with the style that you have chosen. Altogether EndNote provides an excellent combination of features and ease of use.

  19. Design and evaluation of wide-range and low-power analog front-end enabling body-implanted devices to monitor charge injection properties

    NASA Astrophysics Data System (ADS)

    Ito, Keita; Uno, Shoma; Goto, Tatsuya; Takezawa, Yoshiki; Harashima, Takuya; Morikawa, Takumi; Nishino, Satoru; Kino, Hisashi; Kiyoyama, Koji; Tanaka, Tetsu

    2017-04-01

    For safe electrical stimulation with body-implanted devices, the degradation of stimulus electrodes must be considered because it causes the unexpected electrolysis of water and the destruction of tissues. To monitor the charge injection property (CIP) of stimulus electrodes while these devices are implanted, we have proposed a charge injection monitoring system (CIMS). CIMS can safely read out voltages produced by a biphasic current pulse to a stimulus electrode and CIP is calculated from waveforms of the acquired voltages. In this paper, we describe a wide-range and low-power analog front-end (AFE) for CIMS that has variable gain-frequency characteristics and low-power analog-to-digital (A/D) conversion to adjust to the degradation of stimulus electrodes. The designed AFE was fabricated with 0.18 µm CMOS technology and achieved a valuable gain of 20-60 dB, an upper cutoff frequency of 0.2-10 kHz, and low-power interleaving A/D conversion. In addition, we successfully measured the CIP of stimulus electrodes for body-implanted devices using CIMS.

  20. End-use quality of soft kernel durum wheat

    USDA-ARS?s Scientific Manuscript database

    Kernel texture is a major determinant of end-use quality of wheat. Durum wheat has very hard kernels. We developed soft kernel durum wheat via Ph1b-mediated homoeologous recombination. The Hardness locus was transferred from Chinese Spring to Svevo durum wheat via back-crossing. ‘Soft Svevo’ had SKC...

  1. Multivariate statistical approach to estimate mixing proportions for unknown end members

    USGS Publications Warehouse

    Valder, Joshua F.; Long, Andrew J.; Davis, Arden D.; Kenner, Scott J.

    2012-01-01

    A multivariate statistical method is presented, which includes principal components analysis (PCA) and an end-member mixing model to estimate unknown end-member hydrochemical compositions and the relative mixing proportions of those end members in mixed waters. PCA, together with the Hotelling T2 statistic and a conceptual model of groundwater flow and mixing, was used in selecting samples that best approximate end members, which then were used as initial values in optimization of the end-member mixing model. This method was tested on controlled datasets (i.e., true values of estimates were known a priori) and found effective in estimating these end members and mixing proportions. The controlled datasets included synthetically generated hydrochemical data, synthetically generated mixing proportions, and laboratory analyses of sample mixtures, which were used in an evaluation of the effectiveness of this method for potential use in actual hydrological settings. For three different scenarios tested, correlation coefficients (R2) for linear regression between the estimated and known values ranged from 0.968 to 0.993 for mixing proportions and from 0.839 to 0.998 for end-member compositions. The method also was applied to field data from a study of end-member mixing in groundwater as a field example and partial method validation.

  2. Synthesis and analysis of precise spaceborne laser ranging systems, volume 1. [link analysis

    NASA Technical Reports Server (NTRS)

    Paddon, E. A.

    1977-01-01

    Measurement accuracy goals of 2 cm rms range estimation error and 0.003 cm/sec rms range rate estimation error, with no more than 1 cm (range) static bias error are requirements for laser measurement systems to be used in planned space-based earth physics investigations. Constraints and parameters were defined for links between a high altitude, transmit/receive satellite (HATRS), and one of three targets: a low altitude target satellite, passive (LATS), and active low altitude target, and a ground-based target, as well as with operations with a primary transmit/receive terminal intended to be carried as a shuttle payload, in conjunction with the Spacelab program.

  3. A novel end-to-end classifier using domain transferred deep convolutional neural networks for biomedical images.

    PubMed

    Pang, Shuchao; Yu, Zhezhou; Orgun, Mehmet A

    2017-03-01

    Highly accurate classification of biomedical images is an essential task in the clinical diagnosis of numerous medical diseases identified from those images. Traditional image classification methods combined with hand-crafted image feature descriptors and various classifiers are not able to effectively improve the accuracy rate and meet the high requirements of classification of biomedical images. The same also holds true for artificial neural network models directly trained with limited biomedical images used as training data or directly used as a black box to extract the deep features based on another distant dataset. In this study, we propose a highly reliable and accurate end-to-end classifier for all kinds of biomedical images via deep learning and transfer learning. We first apply domain transferred deep convolutional neural network for building a deep model; and then develop an overall deep learning architecture based on the raw pixels of original biomedical images using supervised training. In our model, we do not need the manual design of the feature space, seek an effective feature vector classifier or segment specific detection object and image patches, which are the main technological difficulties in the adoption of traditional image classification methods. Moreover, we do not need to be concerned with whether there are large training sets of annotated biomedical images, affordable parallel computing resources featuring GPUs or long times to wait for training a perfect deep model, which are the main problems to train deep neural networks for biomedical image classification as observed in recent works. With the utilization of a simple data augmentation method and fast convergence speed, our algorithm can achieve the best accuracy rate and outstanding classification ability for biomedical images. We have evaluated our classifier on several well-known public biomedical datasets and compared it with several state-of-the-art approaches. We propose a robust

  4. Point of data saturation was assessed using resampling methods in a survey with open-ended questions.

    PubMed

    Tran, Viet-Thi; Porcher, Raphael; Falissard, Bruno; Ravaud, Philippe

    2016-12-01

    To describe methods to determine sample sizes in surveys using open-ended questions and to assess how resampling methods can be used to determine data saturation in these surveys. We searched the literature for surveys with open-ended questions and assessed the methods used to determine sample size in 100 studies selected at random. Then, we used Monte Carlo simulations on data from a previous study on the burden of treatment to assess the probability of identifying new themes as a function of the number of patients recruited. In the literature, 85% of researchers used a convenience sample, with a median size of 167 participants (interquartile range [IQR] = 69-406). In our simulation study, the probability of identifying at least one new theme for the next included subject was 32%, 24%, and 12% after the inclusion of 30, 50, and 100 subjects, respectively. The inclusion of 150 participants at random resulted in the identification of 92% themes (IQR = 91-93%) identified in the original study. In our study, data saturation was most certainly reached for samples >150 participants. Our method may be used to determine when to continue the study to find new themes or stop because of futility. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. WISDOM-II: screening against multiple targets implicated in malaria using computational grid infrastructures.

    PubMed

    Kasam, Vinod; Salzemann, Jean; Botha, Marli; Dacosta, Ana; Degliesposti, Gianluca; Isea, Raul; Kim, Doman; Maass, Astrid; Kenyon, Colin; Rastelli, Giulio; Hofmann-Apitius, Martin; Breton, Vincent

    2009-05-01

    Despite continuous efforts of the international community to reduce the impact of malaria on developing countries, no significant progress has been made in the recent years and the discovery of new drugs is more than ever needed. Out of the many proteins involved in the metabolic activities of the Plasmodium parasite, some are promising targets to carry out rational drug discovery. Recent years have witnessed the emergence of grids, which are highly distributed computing infrastructures particularly well fitted for embarrassingly parallel computations like docking. In 2005, a first attempt at using grids for large-scale virtual screening focused on plasmepsins and ended up in the identification of previously unknown scaffolds, which were confirmed in vitro to be active plasmepsin inhibitors. Following this success, a second deployment took place in the fall of 2006 focussing on one well known target, dihydrofolate reductase (DHFR), and on a new promising one, glutathione-S-transferase. In silico drug design, especially vHTS is a widely and well-accepted technology in lead identification and lead optimization. This approach, therefore builds, upon the progress made in computational chemistry to achieve more accurate in silico docking and in information technology to design and operate large scale grid infrastructures. On the computational side, a sustained infrastructure has been developed: docking at large scale, using different strategies in result analysis, storing of the results on the fly into MySQL databases and application of molecular dynamics refinement are MM-PBSA and MM-GBSA rescoring. The modeling results obtained are very promising. Based on the modeling results, In vitro results are underway for all the targets against which screening is performed. The current paper describes the rational drug discovery activity at large scale, especially molecular docking using FlexX software on computational grids in finding hits against three different targets (Pf

  6. A deep learning framework for improving long-range residue-residue contact prediction using a hierarchical strategy.

    PubMed

    Xiong, Dapeng; Zeng, Jianyang; Gong, Haipeng

    2017-09-01

    Residue-residue contacts are of great value for protein structure prediction, since contact information, especially from those long-range residue pairs, can significantly reduce the complexity of conformational sampling for protein structure prediction in practice. Despite progresses in the past decade on protein targets with abundant homologous sequences, accurate contact prediction for proteins with limited sequence information is still far from satisfaction. Methodologies for these hard targets still need further improvement. We presented a computational program DeepConPred, which includes a pipeline of two novel deep-learning-based methods (DeepCCon and DeepRCon) as well as a contact refinement step, to improve the prediction of long-range residue contacts from primary sequences. When compared with previous prediction approaches, our framework employed an effective scheme to identify optimal and important features for contact prediction, and was only trained with coevolutionary information derived from a limited number of homologous sequences to ensure robustness and usefulness for hard targets. Independent tests showed that 59.33%/49.97%, 64.39%/54.01% and 70.00%/59.81% of the top L/5, top L/10 and top 5 predictions were correct for CASP10/CASP11 proteins, respectively. In general, our algorithm ranked as one of the best methods for CASP targets. All source data and codes are available at http://166.111.152.91/Downloads.html . hgong@tsinghua.edu.cn or zengjy321@tsinghua.edu.cn. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  7. Feasibility of achieving the 2025 WHO global tuberculosis targets in South Africa, China, and India: a combined analysis of 11 mathematical models.

    PubMed

    Houben, Rein M G J; Menzies, Nicolas A; Sumner, Tom; Huynh, Grace H; Arinaminpathy, Nimalan; Goldhaber-Fiebert, Jeremy D; Lin, Hsien-Ho; Wu, Chieh-Yin; Mandal, Sandip; Pandey, Surabhi; Suen, Sze-Chuan; Bendavid, Eran; Azman, Andrew S; Dowdy, David W; Bacaër, Nicolas; Rhines, Allison S; Feldman, Marcus W; Handel, Andreas; Whalen, Christopher C; Chang, Stewart T; Wagner, Bradley G; Eckhoff, Philip A; Trauer, James M; Denholm, Justin T; McBryde, Emma S; Cohen, Ted; Salomon, Joshua A; Pretorius, Carel; Lalli, Marek; Eaton, Jeffrey W; Boccia, Delia; Hosseini, Mehran; Gomez, Gabriela B; Sahu, Suvanand; Daniels, Colleen; Ditiu, Lucica; Chin, Daniel P; Wang, Lixia; Chadha, Vineet K; Rade, Kiran; Dewan, Puneet; Hippner, Piotr; Charalambous, Salome; Grant, Alison D; Churchyard, Gavin; Pillay, Yogan; Mametja, L David; Kimerling, Michael E; Vassall, Anna; White, Richard G

    2016-11-01

    The post-2015 End TB Strategy proposes targets of 50% reduction in tuberculosis incidence and 75% reduction in mortality from tuberculosis by 2025. We aimed to assess whether these targets are feasible in three high-burden countries with contrasting epidemiology and previous programmatic achievements. 11 independently developed mathematical models of tuberculosis transmission projected the epidemiological impact of currently available tuberculosis interventions for prevention, diagnosis, and treatment in China, India, and South Africa. Models were calibrated with data on tuberculosis incidence and mortality in 2012. Representatives from national tuberculosis programmes and the advocacy community provided distinct country-specific intervention scenarios, which included screening for symptoms, active case finding, and preventive therapy. Aggressive scale-up of any single intervention scenario could not achieve the post-2015 End TB Strategy targets in any country. However, the models projected that, in the South Africa national tuberculosis programme scenario, a combination of continuous isoniazid preventive therapy for individuals on antiretroviral therapy, expanded facility-based screening for symptoms of tuberculosis at health centres, and improved tuberculosis care could achieve a 55% reduction in incidence (range 31-62%) and a 72% reduction in mortality (range 64-82%) compared with 2015 levels. For India, and particularly for China, full scale-up of all interventions in tuberculosis-programme performance fell short of the 2025 targets, despite preventing a cumulative 3·4 million cases. The advocacy scenarios illustrated the high impact of detecting and treating latent tuberculosis. Major reductions in tuberculosis burden seem possible with current interventions. However, additional interventions, adapted to country-specific tuberculosis epidemiology and health systems, are needed to reach the post-2015 End TB Strategy targets at country level. Bill and Melinda

  8. End-use quality of soft kernel durum wheat

    USDA-ARS?s Scientific Manuscript database

    Kernel texture is a major determinant of end-use quality of wheat. Durum wheat is known for its very hard texture, which influences how it is milled and for what products it is well suited. We developed soft kernel durum wheat lines via Ph1b-mediated homoeologous recombination with Dr. Leonard Joppa...

  9. [Treatment of painful neuromas via end-to-side neurorraphy].

    PubMed

    Aszmann, O C; Moser, V; Frey, M

    2010-08-01

    Management of the painful neuroma has been subject to controversy since the earliest descriptions of this disabling problem. Today, treatment is limited to resection of the neuroma and implantation of the nerve in a muscle at a location where it is safe from irritation and trauma. This however is not attainable in many cases and it is our clinical experience, that nerves without a target remain a source of constant discomfort and pain. Recently we reported of the feasibility of neuroma prevention through end-to-side neurorraphy into adjacent sensory and/or motor nerves to provide a target for axons deprived of their endorgan. Here we report of our first clinical experience with this method in sixteen patients with longstanding upper and lower extremity neuromas. 16 patients were included in this study. All had neuromas of different sensory nerves of both the upper and lower extremity. 11 were of iatrogenic origin, 5 were caused by different traumas. 8 had previous attempts to surgically treat the neuroma. Finally, all were treated by end-to-side neurorraphy into adjacent nerves. Postoperatively quantitative sensorymotor testing was performed to evaluate possible changes of nerve function of the recipient nerves. Pain was evaluated by visual analogue score and changes in pain medication. In no patient a sensory or motor deficit or painful sensations were induced in the target area of the recipient nerve. Some had dysaesthesias for about 6 months, which finally subsided. All but 1 patient improved in their symptoms at a follow-up of more than 2 years. Previous experimental work and present clinical results suggest that axons of a severed peripheral nerve that are provided with a pathway and target through an end-to-side coaptation will either be pruned or establish some type of end-organ contact so that a neuroma can be prevented without inducing sensory or motor dysfunctions in the recipient nerve. Georg Thieme Verlag KG Stuttgart New York.

  10. Target charging in short-pulse-laser-plasma experiments.

    PubMed

    Dubois, J-L; Lubrano-Lavaderci, F; Raffestin, D; Ribolzi, J; Gazave, J; Compant La Fontaine, A; d'Humières, E; Hulin, S; Nicolaï, Ph; Poyé, A; Tikhonchuk, V T

    2014-01-01

    Interaction of high-intensity laser pulses with solid targets results in generation of large quantities of energetic electrons that are the origin of various effects such as intense x-ray emission, ion acceleration, and so on. Some of these electrons are escaping the target, leaving behind a significant positive electric charge and creating a strong electromagnetic pulse long after the end of the laser pulse. We propose here a detailed model of the target electric polarization induced by a short and intense laser pulse and an escaping electron bunch. A specially designed experiment provides direct measurements of the target polarization and the discharge current in the function of the laser energy, pulse duration, and target size. Large-scale numerical simulations describe the energetic electron generation and their emission from the target. The model, experiment, and numerical simulations demonstrate that the hot-electron ejection may continue long after the laser pulse ends, enhancing significantly the polarization charge.

  11. Electronic nicotine delivery system (ENDS) use during smoking cessation: a qualitative study of 40 Oklahoma quitline callers.

    PubMed

    Vickerman, Katrina A; Beebe, Laura A; Schauer, Gillian L; Magnusson, Brooke; King, Brian A

    2017-04-01

    Approximately 10% (40 000) of US quitline enrollees who smoke cigarettes report current use of electronic nicotine delivery systems (ENDS); however, little is known about callers' ENDS use. Our aim was to describe why and how quitline callers use ENDS, their beliefs about ENDS and the impact of ENDS use on callers' quit processes and use of FDA-approved cessation medications. Qualitative interviews conducted 1-month postregistration. Interviews were recorded, transcribed, double-coded and analysed to identify themes. Oklahoma Tobacco Helpline. 40 callers aged ≥18 who were seeking help to quit smoking were using ENDS at registration and completed ≥1 programme calls. At 1-month postregistration interview, 80% of callers had smoked cigarettes in the last 7 days, almost two-thirds were using ENDS, and half were using cessation medications. Nearly all believed ENDS helped them quit or cut down on smoking; however, participants were split on whether they would recommend cessation medications, ENDS or both together for quitting. Confusion and misinformation about potential harms of ENDS and cessation medications were reported. Participants reported using ENDS in potentially adaptive ways (eg, using ENDS to cut down and nicotine replacement therapy to quit, and stepping down nicotine in ENDS to wean off ENDS after quitting) and maladaptive ways (eg, frequent automatic ENDS use, using ENDS in situations they did not previously smoke, cutting down on smoking using ENDS without a schedule or plan to quit), which could impact the likelihood of quitting smoking or continuing ENDS use. These qualitative findings suggest quitline callers who use ENDS experience confusion and misinformation about ENDS and FDA-approved cessation medications. Callers also use ENDS in ways that may not facilitate quitting smoking. Opportunities exist for quitlines to educate ENDS users and help them create a coordinated plan most likely to result in completely quitting combustible tobacco

  12. Laser long-range remote-sensing program experimental results

    NASA Astrophysics Data System (ADS)

    Highland, Ronald G.; Shilko, Michael L.; Fox, Marsha J.; Gonglewski, John D.; Czyzak, Stanley R.; Dowling, James A.; Kelly, Brian; Pierrottet, Diego F.; Ruffatto, Donald; Loando, Sharon; Matsuura, Chris; Senft, Daniel C.; Finkner, Lyle; Rae, Joe; Gallegos, Joe

    1995-12-01

    A laser long range remote sensing (LRS) program is being conducted by the United States Air Force Phillips Laboratory (AF/PL). As part of this program, AF/PL is testing the feasibility of developing a long path CO(subscript 2) laser-based DIAL system for remote sensing. In support of this program, the AF/PL has recently completed an experimental series using a 21 km slant- range path (3.05 km ASL transceiver height to 0.067 km ASL target height) at its Phillips Laboratory Air Force Maui Optical Station (AMOS) facility located on Maui, Hawaii. The dial system uses a 3-joule, (superscript 13)C isotope laser coupled into a 0.6 m diameter telescope. The atmospheric optical characterization incorporates information from an infrared scintillometer co-aligned to the laser path, atmospheric profiles from weather balloons launched from the target site, and meteorological data from ground stations at AMOS and the target site. In this paper, we report a description of the experiment configuration, a summary of the results, a summary of the atmospheric conditions and their implications to the LRS program. The capability of such a system for long-range, low-angle, slant-path remote sensing is discussed. System performance issues relating to both coherent and incoherent detection methods, atmospheric limitations, as well as, the development of advanced models to predict performance of long range scenarios are presented.

  13. Cut! that’s a wrap: regulating negative emotion by ending emotion-eliciting situations

    PubMed Central

    Vujovic, Lara; Opitz, Philipp C.; Birk, Jeffrey L.; Urry, Heather L.

    2014-01-01

    Little is known about the potentially powerful set of emotion regulation (ER) processes that target emotion-eliciting situations. We thus studied the decision to end emotion-eliciting situations in the laboratory. We hypothesized that people would try to end negative situations more frequently than neutral situations to regulate distress. In addition, motivated by the selection, optimization, and compensation with ER framework, we hypothesized that failed attempts to end the situation would prompt either (a) greater negative emotion or (b) compensatory use of a different ER process, attentional deployment (AD). Fifty-eight participants (18–26 years old, 67% women) viewed negative and neutral pictures and pressed a key whenever they wished to stop viewing them. After key press, the picture disappeared (“success”) or stayed (“failure”) on screen. To index emotion, we measured corrugator and electrodermal activity, heart rate, and self-reported arousal. To index overt AD, we measured eye gaze. As their reason for ending the situation, participants more frequently reported being upset by high- than low-arousal negative pictures; they more frequently reported being bored by low- than high-arousal neutral pictures. Nevertheless, participants’ negative emotional responding did not increase in the context of ER failure nor did they use overt AD as a compensatory ER strategy. We conclude that situation-targeted ER processes are used to regulate emotional responses to high-arousal negative and low-arousal neutral situations; ER processes other than overt AD may be used to compensate for ER failure in this context. PMID:24592251

  14. Hyperspectral target detection using manifold learning and multiple target spectra

    DOE PAGES

    Ziemann, Amanda K.; Theiler, James; Messinger, David W.

    2016-03-31

    Imagery collected from satellites and airborne platforms provides an important tool for remotely analyzing the content of a scene. In particular, the ability to remotely detect a specific material within a scene is of critical importance in nonproliferation and other applications. The sensor systems that process hyperspectral images collect the high-dimensional spectral information necessary to perform these detection analyses. For a d-dimensional hyperspectral image, however, where d is the number of spectral bands, it is common for the data to inherently occupy an m-dimensional space with m << d. In the remote sensing community, this has led to recent interestmore » in the use of manifold learning, which seeks to characterize the embedded lower-dimensional, nonlinear manifold that the data discretely approximate. The research presented in this paper focuses on a graph theory and manifold learning approach to target detection, using an adaptive version of locally linear embedding that is biased to separate target pixels from background pixels. Finally, this approach incorporates multiple target signatures for a particular material, accounting for the spectral variability that is often present within a solid material of interest.« less

  15. Rack Insertion End Effector (RIEE) guidance

    NASA Technical Reports Server (NTRS)

    Malladi, Narasimha S.

    1994-01-01

    NASA-KSC has developed a mechanism to handle and insert Racks into the Space Station Logistic Modules. This mechanism consists of a Base with 3 motorized degrees of freedom, a 3 section motorized Boom that goes from 15 to 44 feet in length, and a Rack Insertion End Effector (RIEE) with 5 hand wheels for precise alignment. During the 1993 NASA-ASEE Summer Faculty Fellowship Program at KSC, I designed an Active Vision (Camera) Arrangement and developed an algorithm to determine (1) the displacements required by the Room for its initial positioning and (2) the rotations required at the five hand-wheels of the RIEE, for the insertion of the Rack, using the centroids fo the Camera Images of the Location Targets in the Logistic Module. Presently, during the summer of '94, I completed the preliminary design of an easily portable measuring instrument using encoders to obtain the 3-Dimensional Coordinates of Location Targets in the Logistics Module relative to the RIEE mechanism frame. The algorithm developed in '93 can use the output of this instrument also. Simplification of the '93 work and suggestions for the future work are discussed.

  16. Optimized ion acceleration using high repetition rate, variable thickness liquid crystal targets

    NASA Astrophysics Data System (ADS)

    Poole, Patrick; Willis, Christopher; Cochran, Ginevra; Andereck, C. David; Schumacher, Douglass

    2015-11-01

    Laser-based ion acceleration is a widely studied plasma physics topic for its applications to secondary radiation sources, advanced imaging, and cancer therapy. Recent work has centered on investigating new acceleration mechanisms that promise improved ion energy and spectrum. While the physics of these mechanisms is not yet fully understood, it has been observed to dominate for certain ranges of target thickness, where the optimum thickness depends on laser conditions including energy, pulse width, and contrast. The study of these phenomena is uniquely facilitated by the use of variable-thickness liquid crystal films, first introduced in P. L. Poole et al. PoP21, 063109 (2014). Control of the formation parameters of these freely suspended films such as volume, temperature, and draw speed allows on-demand thickness variability between 10 nanometers and several 10s of microns, fully encompassing the currently studied thickness regimes with a single target material. The low vapor pressure of liquid crystal enables in-situ film formation and unlimited vacuum use of these targets. Details on the selection and optimization of ion acceleration mechanism with target thickness will be presented, including recent experiments on the Scarlet laser facility and others. This work was performed with support from the DARPA PULSE program through a grant from AMRDEC and by the NNSA under contract DE-NA0001976.

  17. Aircraft Range Optimization Using Singular Perturbations

    NASA Technical Reports Server (NTRS)

    Oconnor, Joseph Taffe

    1973-01-01

    An approximate analytic solution is developed for the problem of maximizing the range of an aircraft for a fixed end state. The problem is formulated as a singular perturbation and solved by matched inner and outer asymptotic expansions and the minimum principle of Pontryagin. Cruise in the stratosphere, and on transition to and from cruise at constant Mach number are discussed. The state vector includes altitude, flight path angle, and mass. Specific fuel consumption becomes a linear function of power approximating that of the cruise values. Cruise represents the outer solution; altitude and flight path angle are constants, and only mass changes. Transitions between cruise and the specified initial and final conditions correspond to the inner solutions. The mass is constant and altitude and velocity vary. A solution is developed which is valid for cruise but which is not for the initial and final conditions. Transforming of the independent variable near the initial and final conditions result in solutions which are valid for the two inner solutions but not for cruise. The inner solutions can not be obtained without simplifying the state equations. The singular perturbation approach overcomes this difficulty. A quadratic approximation of the state equations is made. The resulting problem is solved analytically, and the two inner solutions are matched to the outer solution.

  18. On the Use of a Range Trigger for the Mars Science Laboratory Entry Descent and Landing

    NASA Technical Reports Server (NTRS)

    Way, David W.

    2011-01-01

    In 2012, during the Entry, Descent, and Landing (EDL) of the Mars Science Laboratory (MSL) entry vehicle, a 21.5 m Viking-heritage, Disk-Gap-Band, supersonic parachute will be deployed at approximately Mach 2. The baseline algorithm for commanding this parachute deployment is a navigated planet-relative velocity trigger. This paper compares the performance of an alternative range-to-go trigger (sometimes referred to as Smart Chute ), which can significantly reduce the landing footprint size. Numerical Monte Carlo results, predicted by the POST2 MSL POST End-to-End EDL simulation, are corroborated and explained by applying propagation of uncertainty methods to develop an analytic estimate for the standard deviation of Mach number. A negative correlation is shown to exist between the standard deviations of wind velocity and the planet-relative velocity at parachute deploy, which mitigates the Mach number rise in the case of the range trigger.

  19. Contact Instrument Calibration Targets on Mars Rover Curiosity

    NASA Image and Video Library

    2012-02-07

    Two instruments at the end of the robotic arm on NASA Mars rover Curiosity will use calibration targets attached to a shoulder joint of the arm. The penny is a size reference giving the public a familiar object for perceiving size on Mars easily.

  20. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dubey, P. K., E-mail: premkdubey@gmail.com; Kumar, Yudhisther; Gupta, Reeta

    2014-05-15

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occursmore » at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.« less

  1. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    NASA Astrophysics Data System (ADS)

    Dubey, P. K.; Kumar, Yudhisther; Gupta, Reeta; Jain, Anshul; Gohiya, Chandrashekhar

    2014-05-01

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.

  2. Grazing-incidence small-angle X-ray scattering (GISAXS) on small periodic targets using large beams

    PubMed Central

    Soltwisch, Victor; Probst, Jürgen; Scholze, Frank; Krumrey, Michael

    2017-01-01

    Grazing-incidence small-angle X-ray scattering (GISAXS) is often used as a versatile tool for the contactless and destruction-free investigation of nano­structured surfaces. However, due to the shallow incidence angles, the footprint of the X-ray beam is significantly elongated, limiting GISAXS to samples with typical target lengths of several millimetres. For many potential applications, the production of large target areas is impractical, and the targets are surrounded by structured areas. Because the beam footprint is larger than the targets, the surrounding structures contribute parasitic scattering, burying the target signal. In this paper, GISAXS measurements of isolated as well as surrounded grating targets in Si substrates with line lengths from 50 µm down to 4 µm are presented. For the isolated grating targets, the changes in the scattering patterns due to the reduced target length are explained. For the surrounded grating targets, the scattering signal of a 15 µm × 15 µm target grating structure is separated from the scattering signal of 100 µm × 100 µm nanostructured surroundings by producing the target with a different orientation with respect to the predominant direction of the surrounding structures. As virtually all litho­graphically produced nanostructures have a predominant direction, the described technique allows GISAXS to be applied in a range of applications, e.g. for characterization of metrology fields in the semiconductor industry, where up to now it has been considered impossible to use this method due to the large beam footprint. PMID:28875030

  3. Grazing-incidence small-angle X-ray scattering (GISAXS) on small periodic targets using large beams.

    PubMed

    Pflüger, Mika; Soltwisch, Victor; Probst, Jürgen; Scholze, Frank; Krumrey, Michael

    2017-07-01

    Grazing-incidence small-angle X-ray scattering (GISAXS) is often used as a versatile tool for the contactless and destruction-free investigation of nano-structured surfaces. However, due to the shallow incidence angles, the footprint of the X-ray beam is significantly elongated, limiting GISAXS to samples with typical target lengths of several millimetres. For many potential applications, the production of large target areas is impractical, and the targets are surrounded by structured areas. Because the beam footprint is larger than the targets, the surrounding structures contribute parasitic scattering, burying the target signal. In this paper, GISAXS measurements of isolated as well as surrounded grating targets in Si substrates with line lengths from 50 µm down to 4 µm are presented. For the isolated grating targets, the changes in the scattering patterns due to the reduced target length are explained. For the surrounded grating targets, the scattering signal of a 15 µm × 15 µm target grating structure is separated from the scattering signal of 100 µm × 100 µm nanostructured surroundings by producing the target with a different orientation with respect to the predominant direction of the surrounding structures. As virtually all litho-graphically produced nanostructures have a predominant direction, the described technique allows GISAXS to be applied in a range of applications, e.g.  for characterization of metrology fields in the semiconductor industry, where up to now it has been considered impossible to use this method due to the large beam footprint.

  4. Targeted Gene Knock Out Using Nuclease-Assisted Vector Integration: Hemi- and Homozygous Deletion of JAG1.

    PubMed

    Gapinske, Michael; Tague, Nathan; Winter, Jackson; Underhill, Gregory H; Perez-Pinera, Pablo

    2018-01-01

    Gene editing technologies are revolutionizing fields such as biomedicine and biotechnology by providing a simple means to manipulate the genetic makeup of essentially any organism. Gene editing tools function by introducing double-stranded breaks at targeted sites within the genome, which the host cells repair preferentially by Non-Homologous End Joining. While the technologies to introduce double-stranded breaks have been extensively optimized, this progress has not been matched by the development of methods to integrate heterologous DNA at the target sites or techniques to detect and isolate cells that harbor the desired modification. We present here a technique for rapid introduction of vectors at target sites in the genome that enables efficient isolation of successfully edited cells.

  5. Active Targets For Capacitive Proximity Sensors

    NASA Technical Reports Server (NTRS)

    Jenstrom, Del T.; Mcconnell, Robert L.

    1994-01-01

    Lightweight, low-power active targets devised for use with improved capacitive proximity sensors described in "Capacitive Proximity Sensor Has Longer Range" (GSC-13377), and "Capacitive Proximity Sensors With Additional Driven Shields" (GSC-13475). Active targets are short-distance electrostatic beacons; they generate known alternating electro-static fields used for alignment and/or to measure distances.

  6. Molding the business end of neurotoxins by diversifying evolution.

    PubMed

    Kozminsky-Atias, Adi; Zilberberg, Noam

    2012-02-01

    A diverse range of organisms utilize neurotoxins that target specific ion channels and modulate their activity. Typically, toxins are clustered into several multigene families, providing an organism with the upper hand in the never-ending predator-prey arms race. Several gene families, including those encoding certain neurotoxins, have been subject to diversifying selection forces, resulting in rapid gene evolution. Here we sought a spatial pattern in the distribution of both diversifying and purifying selection forces common to neurotoxin gene families. Utilizing the mechanistic empirical combination model, we analyzed various toxin families from different phyla affecting various receptors and relying on diverse modes of action. Through this approach, we were able to detect clear correlations between the pharmacological surface of a toxin and rapidly evolving domains, rich in positively selected residues. On the other hand, patches of negatively selected residues were restricted to the nontoxic face of the molecule and most likely help in stabilizing the tertiary structure of the toxin. We thus propose a mutual evolutionary strategy of venomous animals in which adaptive molecular evolution is directed toward the toxin active surface. Furthermore, we propose that the binding domains of unstudied toxins could be readily predicted using evolutionary considerations.

  7. An Adaptive Moving Target Imaging Method for Bistatic Forward-Looking SAR Using Keystone Transform and Optimization NLCS.

    PubMed

    Li, Zhongyu; Wu, Junjie; Huang, Yulin; Yang, Haiguang; Yang, Jianyu

    2017-01-23

    Bistatic forward-looking SAR (BFSAR) is a kind of bistatic synthetic aperture radar (SAR) system that can image forward-looking terrain in the flight direction of an aircraft. Until now, BFSAR imaging theories and methods for a stationary scene have been researched thoroughly. However, for moving-target imaging with BFSAR, the non-cooperative movement of the moving target induces some new issues: (I) large and unknown range cell migration (RCM) (including range walk and high-order RCM); (II) the spatial-variances of the Doppler parameters (including the Doppler centroid and high-order Doppler) are not only unknown, but also nonlinear for different point-scatterers. In this paper, we put forward an adaptive moving-target imaging method for BFSAR. First, the large and unknown range walk is corrected by applying keystone transform over the whole received echo, and then, the relationships among the unknown high-order RCM, the nonlinear spatial-variances of the Doppler parameters, and the speed of the mover, are established. After that, using an optimization nonlinear chirp scaling (NLCS) technique, not only can the unknown high-order RCM be accurately corrected, but also the nonlinear spatial-variances of the Doppler parameters can be balanced. At last, a high-order polynomial filter is applied to compress the whole azimuth data of the moving target. Numerical simulations verify the effectiveness of the proposed method.

  8. Comparison of closed-ended, open-ended, and perceived informed consent comprehension measures for a mock HIV prevention trial among women in Tanzania.

    PubMed

    MacQueen, Kathleen M; Chen, Mario; Ramirez, Catalina; Nnko, Soori E A; Earp, Kelly M

    2014-01-01

    Verifying participant comprehension continues to be a difficult ethical and regulatory challenge for clinical research. An increasing number of articles assessing methods to improve comprehension have been published, but they use a wide range of outcome measures including open-ended, closed-ended, and self-perceived measures of comprehension. Systematic comparisons of different measures have rarely been reported. This study evaluated the likely direction of bias observed when using open-ended, closed-ended, and perceived ease of comprehension measures among women administered a mock informed consent process in Mwanza, Tanzania. Participants were randomized to either a closed-ended or an open-ended assessment of comprehension, administered the consent process for a hypothetical HIV prevention trial in Kiswahili, and then administered a comprehension assessment, per their randomization. They were then asked how easy or hard it was to understand each of the informed consent components measured in the comprehension assessment. Women in the closed-ended arm had significantly higher overall comprehension scores than in the open-ended arm. Perceived scores were significantly higher when compared to both open-ended and close-ended scores within arms but were similar between arms. Findings highlight the importance of comprehension assessments in complex clinical trials that go beyond asking participants if they understand or have any questions. They also indicate the need for continued exploration of objective measures of comprehension in international clinical research settings, so that points in need of clarification can be efficiently and effectively identified and addressed. Such measures would reduce burdens on both staff and participants that result from well-intentioned but potentially unnecessary time spent explaining in unwarranted detail things already understood.

  9. Differential Optical Absorption Spectroscopy (DOAS) using Targets: SO2 and NO2 Measurements in Montevideo City

    NASA Astrophysics Data System (ADS)

    Louban, Ilia; Píriz, Gustavo; Platt, Ulrich; Frins, Erna

    2008-04-01

    SO2 and NO2 were remotely measured in a main street of Montevideo city using Multiaxis-Differential Optical Absorption Spectroscopy (MAX-DOAS) combined with on-field selected targets. Target-based measurements are the basis of a new experimental procedure called Topographic Target Light scattering-DOAS (TOTAL-DOAS) that provides a well define absorption path to measure the near surface distribution of trace gases in the boundary layer. It combines the measurement principles of the long-path DOAS and zenith-scattered sunlight DOAS, within the near UV and VIS spectral range. We give a general description of the procedure and present first results of the 2006 campaign at Montevideo.

  10. Target surface finding using 3D SAR data

    NASA Astrophysics Data System (ADS)

    Ruiter, Jason R.; Burns, Joseph W.; Subotic, Nikola S.

    2005-05-01

    Methods of generating more literal, easily interpretable imagery from 3-D SAR data are being studied to provide all weather, near-visual target identification and/or scene interpretation. One method of approaching this problem is to automatically generate shape-based geometric renderings from the SAR data. In this paper we describe the application of the Marching Tetrahedrons surface finding algorithm to 3-D SAR data. The Marching Tetrahedrons algorithm finds a surface through the 3-D data cube, which provides a recognizable representation of the target surface. This algorithm was applied to the public-release X-patch simulations of a backhoe, which provided densely sampled 3-D SAR data sets. The performance of the algorithm to noise and spatial resolution were explored. Surface renderings were readily recognizable over a range of spatial resolution, and maintained their fidelity even under relatively low Signal-to-Noise Ratio (SNR) conditions.

  11. Using Peer Feedback to Promote Reflection on Open-Ended Problems

    NASA Astrophysics Data System (ADS)

    Reinholz, Daniel L.; Dounas-Frazer, Dimitri R.

    2016-09-01

    This paper describes a new approach for learning from homework called Peer-Assisted Reflection (PAR). PAR involves students using peer feedback to improve their work on open-ended homework problems. Collaborating with peers and revising one's work based on the feedback of others are important aspects of doing and learning physics. While notable exceptions exist, homework and exams are generally individual activities that do not support collaboration and refinement, which misses important opportunities to use assessment for learning. In contrast, PAR provides students with a structure to iteratively engage with challenging, open-ended problems and solicit the input of their peers to improve their work.

  12. Ranging Apparatus and Method Implementing Stereo Vision System

    NASA Technical Reports Server (NTRS)

    Li, Larry C. (Inventor); Cox, Brian J. (Inventor)

    1997-01-01

    A laser-directed ranging system for use in telerobotics applications and other applications involving physically handicapped individuals. The ranging system includes a left and right video camera mounted on a camera platform, and a remotely positioned operator. The position of the camera platform is controlled by three servo motors to orient the roll axis, pitch axis and yaw axis of the video cameras, based upon an operator input such as head motion. A laser is provided between the left and right video camera and is directed by the user to point to a target device. The images produced by the left and right video cameras are processed to eliminate all background images except for the spot created by the laser. This processing is performed by creating a digital image of the target prior to illumination by the laser, and then eliminating common pixels from the subsequent digital image which includes the laser spot. The horizontal disparity between the two processed images is calculated for use in a stereometric ranging analysis from which range is determined.

  13. Targeted stock identification using multilocus genotype 'familyprinting'

    USGS Publications Warehouse

    Letcher, B.H.; King, T.L.

    1999-01-01

    We present an approach to stock identification of small, targeted populations that uses multilocus microsatellite genotypes of individual mating adults to uniquely identify first- and second-generation offspring in a mixture. We call the approach 'familyprinting'; unlike DNA fingerprinting where tissue samples of individuals are matched, offspring from various families are assigned to pairs of parents or sets of four grandparents with known genotypes. The basic unit of identification is the family, but families can be nested within a variety of stock units ranging from naturally reproducing groups of fish in a small tributary or pond from which mating adults can be sampled to large or small collections of families produced in hatcheries and stocked in specific locations. We show that, with as few as seven alleles per locus using four loci without error, first-generation offspring can be uniquely assigned to the correct family. For second-generation applications in a hatchery more alleles per locus (10) and loci (10) are required for correct assignment of all offspring to the correct set of grandparents. Using microsatellite DNA variation from an Atlantic salmon (Salmo solar) restoration river (Connecticut River, USA), we also show that this population contains sufficient genetic diversity in sea-run returns for 100% correct first, generation assignment and 97% correct second-generation assignment using 14 loci. We are currently using first- and second-generation familyprinting in this population with the ultimate goal of identifying stocking tributary. In addition to within-river familyprinting, there also appears to be sufficient genetic diversity within and between Atlantic salmon populations for identification of 'familyprinted' fish in a mixture of multiple populations. We also suggest that second-generation familyprinting with multiple populations may also provide a tool for examining stock structure. Familyprinting with microsatellite DNA markers is a viable

  14. Discrete range clustering using Monte Carlo methods

    NASA Technical Reports Server (NTRS)

    Chatterji, G. B.; Sridhar, B.

    1993-01-01

    For automatic obstacle avoidance guidance during rotorcraft low altitude flight, a reliable model of the nearby environment is needed. Such a model may be constructed by applying surface fitting techniques to the dense range map obtained by active sensing using radars. However, for covertness, passive sensing techniques using electro-optic sensors are desirable. As opposed to the dense range map obtained via active sensing, passive sensing algorithms produce reliable range at sparse locations, and therefore, surface fitting techniques to fill the gaps in the range measurement are not directly applicable. Both for automatic guidance and as a display for aiding the pilot, these discrete ranges need to be grouped into sets which correspond to objects in the nearby environment. The focus of this paper is on using Monte Carlo methods for clustering range points into meaningful groups. One of the aims of the paper is to explore whether simulated annealing methods offer significant advantage over the basic Monte Carlo method for this class of problems. We compare three different approaches and present application results of these algorithms to a laboratory image sequence and a helicopter flight sequence.

  15. Prevention of doxorubicin-induced cardiomyopathy using targeted MaFGF mediated by nanoparticles combined with ultrasound-targeted MB destruction

    PubMed Central

    Zheng, Lei; ZhuGe, De-Li; Chen, Bin; Lu, Cui-Tao; Yuan, Jian-Jun; Zhao, Ying-Zheng

    2017-01-01

    The present study seeks to observe the preventive effects of doxorubicin-induced cardiomyopathy (DOX-CM) in rats using targeted non-mitogenic acidic fibroblast growth factor (MaFGF) mediated by nanoparticles (NP) combined with ultrasound-targeted MB destruction (UTMD). DOX-CM rats were induced by intraperitoneally injected doxorubicin. Six weeks after intervention, the indices from the transthoracic echocardiography and velocity vector imaging showed that the left ventricular function in the MaFGF-loaded NP (MaFGF-NP) + UTMD group was significantly improved compared with the DOX-CM group. The increased malondialdehyde and decreased superoxide dismutase were observed in the DOX-CM group, while a significant increase in superoxide dismutase and a decrease in malondialdehyde were detected in the groups treated with MaFGF-NP + UTMD. From the Masson staining, the MaFGF-NP + UTMD group showed a significant difference from the DOX-CM group. The cardiac collagen volume fraction and the ratio of the perivascular collagen area to the luminal area number of terminal deoxynucleotidyl transferase-mediated deoxyuridine triphosphate nick end labelling positive cells in the MaFGF-NP + UTMD group decreased to 8.9%, 0.55-fold, compared with the DOX-CM group (26.5%, 1.7-fold). From terminal deoxynucleotidyl transferase-mediated deoxyuridine triphosphate nick end labelling staining, the results showed the strongest inhibition of apoptosis progress in MaFGF-NP + UTMD group. The immunohistochemical staining of the TGF-β1 in MaFGF-NP + UTMD group reached 3.6%, which was much lower than that of the DOX-CM group (12.6%). These results confirmed that the abnormalities, including left ventricular dysfunction, myocardial fibrosis, cardiomyocytes apoptosis and oxidative stress, could be suppressed by twice weekly MaFGF treatments for 6 consecutive weeks (free MaFGF or MaFGF-NP+/UTMD), with the strongest improvements observed in the MaFGF-NP + UTMD group. Western blot analyses of the heart

  16. Use of the historic range of variability to evaluate ecosystem sustainability [Chapter 24

    Treesearch

    Carolyn B. Meyer; Dennis H. Knight; Greg K. Dillon

    2010-01-01

    Ecosystems are not static, having evolved with disturbances such as fire, windstorms, floods, disease, and animal activity. The natural variability imposed by such disturbances must be included when defining sustainability goals. One approach is to target the historic range of variability (HRV), determining if current management maintains the ecosystem within its HRV....

  17. Kinetics of end-to-end collision in short single-stranded nucleic acids.

    PubMed

    Wang, Xiaojuan; Nau, Werner M

    2004-01-28

    A novel fluorescence-based method, which entails contact quenching of the long-lived fluorescent state of 2,3-diazabicyclo[2.2.2]-oct-2-ene (DBO), was employed to measure the kinetics of end-to-end collision in short single-stranded oligodeoxyribonucleotides of the type 5'-DBO-(X)n-dG with X = dA, dC, dT, or dU and n = 2 or 4. The fluorophore was covalently attached to the 5' end and dG was introduced as an efficient intrinsic quencher at the 3' terminus. The end-to-end collision rates, which can be directly related to the efficiency of intramolecular fluorescence quenching, ranged from 0.1 to 9.0 x 10(6) s(-1). They were strongly dependent on the strand length, the base sequence, as well as the temperature. Oligonucleotides containing dA in the backbone displayed much slower collision rates and significantly higher positive activation energies than strands composed of pyrimidine bases, suggesting a higher intrinsic rigidity of oligoadenylate. Comparison of the measured collision rates in short single-stranded oligodeoxyribonucleotides with the previously reported kinetics of hairpin formation indicates that the intramolecular collision is significantly faster than the nucleation step of hairpin closing. This is consistent with the configurational diffusion model suggested by Ansari et al. (Ansari, A.; Kuznetsov, S. V.; Shen, Y. Proc.Natl. Acad. Sci. USA 2001, 98, 7771-7776), in which the formation of misfolded loops is thought to slow hairpin formation.

  18. End-Users, Front Ends and Librarians.

    ERIC Educational Resources Information Center

    Bourne, Donna E.

    1989-01-01

    The increase in end-user searching, the advantages and limitations of front ends, and the role of the librarian in end-user searching are discussed. It is argued that librarians need to recognize that front ends can be of benefit to themselves and patrons, and to assume the role of advisors and educators for end-users. (37 references) (CLB)

  19. Species-specific markers for the differential diagnosis of Trypanosoma cruzi and Trypanosoma rangeli and polymorphisms detection in Trypanosoma rangeli.

    PubMed

    Ferreira, Keila Adriana Magalhães; Fajardo, Emanuella Francisco; Baptista, Rodrigo P; Macedo, Andrea Mara; Lages-Silva, Eliane; Ramírez, Luis Eduardo; Pedrosa, André Luiz

    2014-06-01

    Trypanosoma cruzi and Trypanosoma rangeli are kinetoplastid parasites which are able to infect humans in Central and South America. Misdiagnosis between these trypanosomes can be avoided by targeting barcoding sequences or genes of each organism. This work aims to analyze the feasibility of using species-specific markers for identification of intraspecific polymorphisms and as target for diagnostic methods by PCR. Accordingly, primers which are able to specifically detect T. cruzi or T. rangeli genomic DNA were characterized. The use of intergenic regions, generally divergent in the trypanosomatids, and the serine carboxypeptidase gene were successful. Using T. rangeli genomic sequences for the identification of group-specific polymorphisms and a polymorphic AT(n) dinucleotide repeat permitted the classification of the strains into two groups, which are entirely coincident with T. rangeli main lineages, KP1 (+) and KP1 (-), previously determined by kinetoplast DNA (kDNA) characterization. The sequences analyzed totalize 622 bp (382 bp represent a hypothetical protein sequence, and 240 bp represent an anonymous sequence), and of these, 581 (93.3%) are conserved sites and 41 bp (6.7%) are polymorphic, with 9 transitions (21.9%), 2 transversions (4.9%), and 30 (73.2%) insertion/deletion events. Taken together, the species-specific markers analyzed may be useful for the development of new strategies for the accurate diagnosis of infections. Furthermore, the identification of T. rangeli polymorphisms has a direct impact in the understanding of the population structure of this parasite.

  20. Immunohistochemical Mapping of Sensory Nerve Endings in the Human Triangular Fibrocartilage Complex.

    PubMed

    Rein, Susanne; Semisch, Manuel; Garcia-Elias, Marc; Lluch, Alex; Zwipp, Hans; Hagert, Elisabet

    2015-10-01

    The triangular fibrocartilage complex is the main stabilizer of the distal radioulnar joint. While static joint stability is constituted by osseous and ligamentous integrity, the dynamic aspects of joint stability chiefly concern proprioceptive control of the compressive and directional muscular forces acting on the joint. Therefore, an investigation of the pattern and types of sensory nerve endings gives more insight in dynamic distal radioulnar joint stability. We aimed to (1) analyze the general distribution of sensory nerve endings and blood vessels; (2) examine interstructural distribution of sensory nerve endings and blood vessels; (3) compare the number and types of mechanoreceptors in each part; and (4) analyze intrastructural distribution of nerve endings at different tissue depth. The subsheath of the extensor carpi ulnaris tendon sheath, the ulnocarpal meniscoid, the articular disc, the dorsal and volar radioulnar ligaments, and the ulnolunate and ulnotriquetral ligaments were dissected from 11 human cadaver wrists. Sensory nerve endings were counted in five levels per specimen as total cell amount/cm(2) after staining with low-affinity neurotrophin receptor p75, protein gene product 9.5, and S-100 protein and thereafter classified according to Freeman and Wyke. All types of sensory corpuscles were found in the various structures of the triangular fibrocartilage complex with the exception of the ulnolunate ligament, which contained only Golgi-like endings, free nerve endings, and unclassifiable corpuscles. The articular disc had only free nerve endings. Furthermore, free nerve endings were the predominant sensory nerve ending (median, 72.6/cm(2); range, 0-469.4/cm(2)) and more prevalent than all other types of mechanoreceptors: Ruffini (median, 0; range, 0-5.6/cm(2); difference of medians, 72.6; p < 0.001), Pacini (median, 0; range, 0-3.8/cm(2); difference of medians, 72.6; p < 0.001), Golgi-like (median, 0; range, 0-2.1/cm(2); difference of medians, 72

  1. Identifying apicoplast-targeting antimalarials using high-throughput compatible approaches

    PubMed Central

    Ekland, Eric H.; Schneider, Jessica; Fidock, David A.

    2011-01-01

    Malarial parasites have evolved resistance to all previously used therapies, and recent evidence suggests emerging resistance to the first-line artemisinins. To identify antimalarials with novel mechanisms of action, we have developed a high-throughput screen targeting the apicoplast organelle of Plasmodium falciparum. Antibiotics known to interfere with this organelle, such as azithromycin, exhibit an unusual phenotype whereby the progeny of drug-treated parasites die. Our screen exploits this phenomenon by assaying for “delayed death” compounds that exhibit a higher potency after two cycles of intraerythrocytic development compared to one. We report a primary assay employing parasites with an integrated copy of a firefly luciferase reporter gene and a secondary flow cytometry-based assay using a nucleic acid stain paired with a mitochondrial vital dye. Screening of the U.S. National Institutes of Health Clinical Collection identified known and novel antimalarials including kitasamycin. This inexpensive macrolide, used for agricultural applications, exhibited an in vitro IC50 in the 50 nM range, comparable to the 30 nM activity of our control drug, azithromycin. Imaging and pharmacologic studies confirmed kitasamycin action against the apicoplast, and in vivo activity was observed in a murine malaria model. These assays provide the foundation for high-throughput campaigns to identify novel chemotypes for combination therapies to treat multidrug-resistant malaria.—Ekland, E. H., Schneider, J., Fidock, D. A. Identifying apicoplast-targeting antimalarials using high-throughput compatible approaches. PMID:21746861

  2. Applicability of ASST-A helium refrigeration system for JLab End Station Refrigerator

    NASA Astrophysics Data System (ADS)

    Hasan, N.; Knudsen, P.; Ganni, V.

    2017-12-01

    The MØLLER experiment at Jefferson Lab (JLab) is a high power (5 kW) liquid hydrogen target scheduled to be operational in the 12 GeV-era. At present, cryogenic loads and targets at three of JLab’s four experimental halls are supported by the End Station Refrigerator (ESR) - a CTI/Helix 1.5 kW 4.5 K refrigerator. It is not capable of supporting the high power target load and a capacity upgrade of the ESR cryogenic system is essential. The ASST-A helium refrigeration system is a 4 kW 4.5 K refrigerator. It was designed and used for the Superconducting Super Collider Lab (SSCL) magnet string test and later obtained by JLab after the cancellation of that project. The modified ASST-A refrigeration system, which will be called ESR-II along with a support flow from JLab’s Central Helium Liquefier (CHL) is considered as an option for the End Station Refrigerator capacity upgrade. The applicability of this system for ESR-II under varying load conditions is investigated. The present paper outlines the findings of this process study.

  3. Teaching End-of-Life Care Using Interprofessional Simulation.

    PubMed

    Gannon, Jane; Motycka, Carol; Egelund, Eric; Kraemer, Dale F; Smith, W Thomas; Solomon, Kathleen

    2017-04-01

    Competency in end-of-life (EOL) care is a growing expectation for health professions students. This study assessed the impact of four EOL care scenarios, using high-fidelity simulation, on the perceived learning needs and attitudes of pharmacy and nursing students. On three campuses, pharmacy students (N = 158) were exposed to standard paper EOL case scenarios, while a fourth campus exposed eight graduate nursing and 37 graduate pharmacy students to simulated versions of the same cases. The paper-based groups produced similar pre-post changes on the End of Life Professional Caregiver Survey. Results were pooled and compared with the simulation-only group, revealing significantly higher changes in pre-post scores for the simulation group. Students participating in the simulation group showed some significant differences in attitudes toward EOL care, compared with students in the classroom setting. [J Nurs Educ. 2017;56(4):205-210.]. Copyright 2017, SLACK Incorporated.

  4. Bidirectional reflectance distribution function based surface modeling of non-Lambertian using intensity data of light detection and ranging.

    PubMed

    Li, Xiaolu; Liang, Yu; Xu, Lijun

    2014-09-01

    To provide a credible model for light detection and ranging (LiDAR) target classification, the focus of this study is on the relationship between intensity data of LiDAR and the bidirectional reflectance distribution function (BRDF). An integration method based on the built-in-lab coaxial laser detection system was advanced. A kind of intermediary BRDF model advanced by Schlick was introduced into the integration method, considering diffuse and specular backscattering characteristics of the surface. A group of measurement campaigns were carried out to investigate the influence of the incident angle and detection range on the measured intensity data. Two extracted parameters r and S(λ) are influenced by different surface features, which illustrate the surface features of the distribution and magnitude of reflected energy, respectively. The combination of two parameters can be used to describe the surface characteristics for target classification in a more plausible way.

  5. High volume fabrication of laser targets using MEMS techniques

    NASA Astrophysics Data System (ADS)

    Spindloe, C.; Arthur, G.; Hall, F.; Tomlinson, S.; Potter, R.; Kar, S.; Green, J.; Higginbotham, A.; Booth, N.; Tolley, M. K.

    2016-04-01

    The latest techniques for the fabrication of high power laser targets, using processes developed for the manufacture of Micro-Electro-Mechanical System (MEMS) devices are discussed. These laser targets are designed to meet the needs of the increased shot numbers that are available in the latest design of laser facilities. Traditionally laser targets have been fabricated using conventional machining or coarse etching processes and have been produced in quantities of 10s to low 100s. Such targets can be used for high complexity experiments such as Inertial Fusion Energy (IFE) studies and can have many complex components that need assembling and characterisation with high precision. Using the techniques that are common to MEMS devices and integrating these with an existing target fabrication capability we are able to manufacture and deliver targets to these systems. It also enables us to manufacture novel targets that have not been possible using other techniques. In addition, developments in the positioning systems that are required to deliver these targets to the laser focus are also required and a system to deliver the target to a focus of an F2 beam at 0.1Hz is discussed.

  6. Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer*

    PubMed Central

    Gallien, Sebastien; Duriez, Elodie; Crone, Catharina; Kellmann, Markus; Moehring, Thomas; Domon, Bruno

    2012-01-01

    There is an immediate need for improved methods to systematically and precisely quantify large sets of peptides in complex biological samples. To date protein quantification in biological samples has been routinely performed on triple quadrupole instruments operated in selected reaction monitoring mode (SRM), and two major challenges remain. Firstly, the number of peptides to be included in one survey experiment needs to be increased to routinely reach several hundreds, and secondly, the degree of selectivity should be improved so as to reliably discriminate the targeted analytes from background interferences. High resolution and accurate mass (HR/AM) analysis on the recently developed Q-Exactive mass spectrometer can potentially address these issues. This instrument presents a unique configuration: it is constituted of an orbitrap mass analyzer equipped with a quadrupole mass filter as the front-end for precursor ion mass selection. This configuration enables new quantitative methods based on HR/AM measurements, including targeted analysis in MS mode (single ion monitoring) and in MS/MS mode (parallel reaction monitoring). The ability of the quadrupole to select a restricted m/z range allows one to overcome the dynamic range limitations associated with trapping devices, and the MS/MS mode provides an additional stage of selectivity. When applied to targeted protein quantification in urine samples and benchmarked with the reference SRM technique, the quadrupole-orbitrap instrument exhibits similar or better performance in terms of selectivity, dynamic range, and sensitivity. This high performance is further enhanced by leveraging the multiplexing capability of the instrument to design novel acquisition methods and apply them to large targeted proteomic studies for the first time, as demonstrated on 770 tryptic yeast peptides analyzed in one 60-min experiment. The increased quality of quadrupole-orbitrap data has the potential to improve existing protein

  7. 76 FR 31598 - Record of Decision for the Barry M. Goldwater Range East Range Enhancements Final Environmental...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    ... Statement. These six proposals include: Proposal 1, Developing a sensor training area; Proposal 4..., Converting a portion of Manned Range 3 into a helicopter gunnery range; Proposal 8, constructing a new... (Volume 75, Number 227, Page 72824) with a wait period that ended on December 27, 2010. The ROD documents...

  8. External calibration of polarimetric radars using point and distributed targets

    NASA Technical Reports Server (NTRS)

    Yueh, S. H.; Kong, J. A.; Shin, R. T.

    1991-01-01

    Polarimetric calibration algorithms using combinations of point targets and reciprocal distributed targets are developed. From the reciprocity relations of distributed targets, and equivalent point target response is derived. Then the problem of polarimetric calibration using two point targets and one distributed target reduces to that using three point targets, which has been previously solved. For calibration using one point target and one reciprocal distributed target, two cases are analyzed with the point target being a trihedral reflector or a polarimetric active radar calibrator (PARC). For both cases, the general solutions of the system distortion matrices are written as a product of a particular solution and a matrix with one free parameter. For the trihedral-reflector case, this free parameter is determined by assuming azimuthal symmetry for the distributed target. For the PARC case, knowledge of one ratio of two covariance matrix elements of the distributed target is required to solve for the free parameter. Numerical results are simulated to demonstrate the usefulness of the developed algorithms.

  9. External calibration of polarimetric radars using point and distributed targets

    NASA Astrophysics Data System (ADS)

    Yueh, S. H.; Kong, J. A.; Shin, R. T.

    1991-08-01

    Polarimetric calibration algorithms using combinations of point targets and reciprocal distributed targets are developed. From the reciprocity relations of distributed targets, and equivalent point target response is derived. Then the problem of polarimetric calibration using two point targets and one distributed target reduces to that using three point targets, which has been previously solved. For calibration using one point target and one reciprocal distributed target, two cases are analyzed with the point target being a trihedral reflector or a polarimetric active radar calibrator (PARC). For both cases, the general solutions of the system distortion matrices are written as a product of a particular solution and a matrix with one free parameter. For the trihedral-reflector case, this free parameter is determined by assuming azimuthal symmetry for the distributed target. For the PARC case, knowledge of one ratio of two covariance matrix elements of the distributed target is required to solve for the free parameter. Numerical results are simulated to demonstrate the usefulness of the developed algorithms.

  10. Basis for selecting soft wheat for end-use quality

    USDA-ARS?s Scientific Manuscript database

    Within the United States, end-use quality of soft wheat (Triticum aestivum L.) is determined by several genetically controlled components: milling yield, flour particle size, and baking characteristics related to flour water absorption caused by glutenin macropolymer, non-starch polysaccharides, and...

  11. Vision-Based Target Finding and Inspection of a Ground Target Using a Multirotor UAV System.

    PubMed

    Hinas, Ajmal; Roberts, Jonathan M; Gonzalez, Felipe

    2017-12-17

    In this paper, a system that uses an algorithm for target detection and navigation and a multirotor Unmanned Aerial Vehicle (UAV) for finding a ground target and inspecting it closely is presented. The system can also be used for accurate and safe delivery of payloads or spot spraying applications in site-specific crop management. A downward-looking camera attached to a multirotor is used to find the target on the ground. The UAV descends to the target and hovers above the target for a few seconds to inspect the target. A high-level decision algorithm based on an OODA (observe, orient, decide, and act) loop was developed as a solution to address the problem. Navigation of the UAV was achieved by continuously sending local position messages to the autopilot via Mavros. The proposed system performed hovering above the target in three different stages: locate, descend, and hover. The system was tested in multiple trials, in simulations and outdoor tests, from heights of 10 m to 40 m. Results show that the system is highly reliable and robust to sensor errors, drift, and external disturbance.

  12. Multi-Target/Multi-Sensor Tracking using Only Range and Doppler Measurements

    DTIC Science & Technology

    2009-04-01

    I+1) k ) represents a global maximum, given the Gaussian components used in our model, and given that P(I) has been fixed using parameter values...on Pattern Analysis and Machine Intelligence, 24 (2002), 381—396. [37] Perlovsky, L. I., Plum, C. P., Franchi , P. R., Tichovolsky, E. J., Choi, D. S

  13. Proton Energy Optimization and Spatial Distribution Analysis from a Thickness Study Using Liquid Crystal Targets

    NASA Astrophysics Data System (ADS)

    Willis, Christopher; Poole, Patrick; Schumacher, Douglas; Freeman, Richard; van Woerkom, Linn

    2016-10-01

    Laser-accelerated ions from thin targets have been widely studied for applications including secondary radiation sources and cancer therapy, with recent studies trending towards thinner targets which can provide improved ion energies and yields. Here we discuss results from an experiment on the Scarlet laser at OSU using variable thickness liquid crystal targets. On this experiment, the spatial and spectral distributions of accelerated ions were measured along target normal and laser axes at varying thicknesses from 150nm to 2000nm at a laser intensity of 1 ×1020W /cm2 . Maximum ion energy was observed for targets in the 600 - 800nm thickness range, with proton energies reaching 24MeV . The ions were further characterized using radiochromic film, revealing an unusual spatial distribution on many laser shots. Here, the peak ion yield falls in an annular ring surrounding the target normal, with an increasing divergence angle as a function of ion energy. Details of these spatial and spectral ion distributions will be presented, including spectral deconvolution of the RCF data, revealing additional trends in the accelerated ion distributions. Supported by the DARPA PULSE program through a Grant from AMRDEC, and by the NNSA under contract DE-NA0001976.

  14. Performance Assessment PCR-Based Assays Targeting Bacteroidales Genetic Markers of Bovine Fecal Pollution▿

    PubMed Central

    Shanks, Orin C.; White, Karen; Kelty, Catherine A.; Hayes, Sam; Sivaganesan, Mano; Jenkins, Michael; Varma, Manju; Haugland, Richard A.

    2010-01-01

    There are numerous PCR-based assays available to characterize bovine fecal pollution in ambient waters. The determination of which approaches are most suitable for field applications can be difficult because each assay targets a different gene, in many cases from different microorganisms, leading to variation in assay performance. We describe a performance evaluation of seven end-point PCR and real-time quantitative PCR (qPCR) assays reported to be associated with either ruminant or bovine feces. Each assay was tested against a reference collection of DNA extracts from 247 individual bovine fecal samples representing 11 different populations and 175 fecal DNA extracts from 24 different animal species. Bovine-associated genetic markers were broadly distributed among individual bovine samples ranging from 39 to 93%. Specificity levels of the assays spanned 47.4% to 100%. End-point PCR sensitivity also varied between assays and among different bovine populations. For qPCR assays, the abundance of each host-associated genetic marker was measured within each bovine population and compared to results of a qPCR assay targeting 16S rRNA gene sequences from Bacteroidales. Experiments indicate large discrepancies in the performance of bovine-associated assays across different bovine populations. Variability in assay performance between host populations suggests that the use of bovine microbial source-tracking applications will require a priori characterization at each watershed of interest. PMID:20061457

  15. Temperature Controller System for Gas Gun Targets

    NASA Astrophysics Data System (ADS)

    Bucholtz, Scott; Sheffield, Stephen

    2005-07-01

    A temperature controller system capable of heating and cooling gas gun targets over the range -75 C to +200 C was designed and tested. The system uses cold nitrogen gas from a liquid nitrogen Dewar for cooling and compressed air for heating. Two gas flow heaters control the gas temperature for both heating and cooling. One heater controls the temperature of the target mounting plate and the other the temperature of a copper tubing coil surrounding the target. Each heater is separately adjustable, so the target material will achieve a uniform temperature throughout its volume. A magnetic gauge with integrated thermocouples was developed to measure the internal temperature of the target. Using this system shock experiments, including equation-of-state measurements and shock initiation of high explosives, can be performed over a range of initial temperatures. Successful tests were completed on Teflon samples. This work was supported by the NNSA Enhanced Surveillance Campaign through contract DE-ACO4-01AL66850.

  16. Temperature Controller System for Gas Gun Targets

    NASA Astrophysics Data System (ADS)

    Bucholtz, S. M.; Gehr, R. J.; Rupp, T. D.; Sheffield, S. A.; Robbins, D. L.

    2006-07-01

    A temperature controller system capable of heating and cooling gas gun targets over the range -75°C to +120°C was designed and tested. The system uses cold nitrogen gas from a liquid nitrogen Dewar for cooling and compressed air for heating. Two gas flow heaters control the gas temperature for both heating and cooling. One heater controls the temperature of the target mounting plate and the other the temperature of a copper tubing coil surrounding the target. Each heater is separately adjustable, so the target material will achieve a uniform temperature throughout its volume. A magnetic gauge membrane with integrated thermocouples was developed to measure the internal temperature of the target. Using this system, multiple magnetic gauge shock experiments, including equation-of-state measurements and shock initiation of high explosives, can be performed over a range of initial temperatures. Successful heating and cooling tests were completed on Teflon samples.

  17. Laser Range and Bearing Finder with No Moving Parts

    NASA Technical Reports Server (NTRS)

    Bryan, Thomas C.; Howard, Richard T.; Book, Michael L.

    2007-01-01

    A proposed laser-based instrument would quickly measure the approximate distance and approximate direction to the closest target within its field of view. The instrument would not contain any moving parts and its mode of operation would not entail scanning over of its field of view. Typically, the instrument would be used to locate a target at a distance on the order of meters to kilometers. The instrument would be best suited for use in an uncluttered setting in which the target is the only or, at worst, the closest object in the vicinity; for example, it could be used aboard an aircraft to detect and track another aircraft flying nearby. The proposed instrument would include a conventional time-of-flight or echo-phase-shift laser range finder, but unlike most other range finders, this one would not generate a narrow cylindrical laser beam; instead, it would generate a conical laser beam spanning the field of view. The instrument would also include a quadrant detector, optics to focus the light returning from the target onto the quadrant detector, and circuitry to synchronize the acquisition of the quadrant-detector output with the arrival of laser light returning from the nearest target. A quadrant detector constantly gathers information from the entire field of view, without scanning; its output is a direct measure of the position of the target-return light spot on the focal plane and is thus a measure of the direction to the target. The instrument should be able to operate at a repetition rate high enough to enable it to track a rapidly moving target. Of course, a target that is not sufficiently reflective could not be located by this instrument. Preferably, retroreflectors should be attached to the target to make it sufficiently reflective.

  18. Motives and perceptions regarding electronic nicotine delivery systems (ENDS) use among adults with mental health conditions.

    PubMed

    Spears, Claire Adams; Jones, Dina M; Weaver, Scott R; Pechacek, Terry F; Eriksen, Michael P

    2018-05-01

    Smoking rates are disproportionately high among adults with mental health conditions (MHC), and recent research suggests that among former smokers, those with MHC are more likely to use electronic nicotine delivery systems (ENDS). This study investigated reasons for ENDS use and related risk perceptions among individuals with versus without MHC. Among adult current ENDS users (n=550), associations between self-reported MHC diagnoses and motives for ENDS use and ENDS risk perceptions were examined, stratified by smoking status. There were no significant associations between MHC status and ENDS motives or perceptions in the overall sample. However, current smokers with MHC indicated thinking more about how ENDS might improve their health, and former smokers with MHC reported thinking less about how ENDS might harm their health, compared to their counterparts without MHC. Former smokers with MHC rated several reasons for ENDS use (e.g., less harmful than regular cigarettes; to quit smoking; appealing flavors) as more important than did those without MHC. Current and former smokers with MHC may be especially optimistic about health benefits of ENDS. However, they might also be prone to health risks of continued ENDS use or concurrent use with traditional cigarettes. It will be important for public health messaging to provide this population with accurate information about benefits and risks of ENDS. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. A Time and Place: The Role of Social Workers in Improving End-of-Life Care.

    PubMed

    Peres, Judith

    2016-01-01

    Americans are living longer, but dying after a prolonged period of management of multiple chronic illnesses and functional disabilities. Despite waves of public and professional activity targeted toward improving care for the dying and supporting the families, gaps in care and challenges in end-of-life care persist. Contentious issues such as the so-called "death panels" or physician payment for discussion of advance directives and care wishes at the end of life; aid in dying; and regarding individuals who actively choose death (case of Brittney Maynard) are continually debated in the public media. Progress toward improvement in the experience of dying remains incremental and change has been slow. With the release of a second Institute of Medicine ( 2014 ) report devoted to what it means to die in America in the 21st century, momentum and opportunity for change may increase. If this is to happen, social workers will need to deliver the range of biopsychosocial care that patients and families so desperately need. However, holistic care of the individual will only improve, if the nation also addresses ongoing systemic problems in financing, policy, and service delivery in end-of-life care.

  20. Effects of fluorescent dyes, quenchers, and dangling ends on DNA duplex stability.

    PubMed

    Moreira, Bernardo G; You, Yong; Behlke, Mark A; Owczarzy, Richard

    2005-02-11

    Single and dual-labeled fluorescent oligodeoxynucleotides are used in many molecular biology applications. We investigated the effects of commonly used fluorescent dyes and quenchers on the thermodynamic stability of a model probe-target DNA duplex. We demonstrate that those effects can be significant. Fluorescent dyes and quenchers were attached to the probe ends. In certain combinations, these groups stabilized the duplex up to 1.8kcal/mol and increased T(m) up to 4.3 degrees C. None of the groups tested significantly destabilized the duplex. Rank order of potency was, starting with the most stabilizing group: Iowa Black RQ approximately Black Hole 2>Cy5 approximately Cy3>Black Hole 1>QSY7 approximately Iowa Black FQ>Texas Red approximately TAMRA>FAM approximately HEX approximately Dabcyl>TET. Longer linkers decreased stabilizing effects. Hybridizations to targets with various dangling ends were also studied and were found to have only minor effects on thermodynamic stability. Depending on the dye/quencher combination employed, it can be important to include thermodynamic contributions from fluorophore and quencher when designing oligonucleotide probe assays.